WorldWideScience

Sample records for iec standard wt01

  1. Changes in IEC standards related to diagnostic radiology

    International Nuclear Information System (INIS)

    Porubszky, T.; Barsai, J.

    2007-01-01

    Complete test of publication follows. Purposes. Technical Committee TC62 of International Electrotechnical Commission (IEC) deals with medical electrical equipment (i.e. medical devices using electricity). Standardization concerning diagnostic radiology equipment is task of its Sub-Committee SC62B. An outlook of its activities and present situation, and especially of radiation protection aspects, is given. Materials and methods. Third edition of basic safety standard for medical electrical equipment IEC 60601-1 was issued in 2005. Elaboration of new collateral and particular standards - applicable together with it - is in progress. These standards are generally at the same time also European - EN - and national standards. There is a great importance of radiation protection in diagnostic X-ray equipment. Collateral standard IEC 6060-1-3 about it was at first issued in 1994. Rapid development of imaging technology demands updating of requirements. SC62B in 2003 founded a maintenance team MT37 for preparation of the second edition of this standard. According to new safety philosophy of IEC all modality specific requirements are to be collected in 'safety and essential performance' particular standards. A new working group WG42 - founded in 2006 - elaborates a new particular standard IEC 60601-2-54 for radiographic and radioscopic equipment. Maintenance team MT32 deals with safety and performance standards for X-ray tube assemblies. The authors actively participate in these activities. Results and discussion. Present and future system of diagnostic radiology IEC standards and some interesting details are presented. Conclusions. International standards - although they are not 'obligatory' - are generally the basis of safety and performance certification of diagnostic radiology equipment and often also of their quality assurance.

  2. TU-G-213-01: IEC and US Committee Activities and Organizational Structure

    Energy Technology Data Exchange (ETDEWEB)

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  3. China and IEC international standardization activities

    Institute of Scientific and Technical Information of China (English)

    Su Zhongmin; Guo Chenguang

    2006-01-01

    @@ International Electrotechnical Commission (IEC), one of the currently worlswide largest and most authoritative international standardization organizations,is specialized in developing and promulgating international standards for the electric and electronic fields, which are widespread adopted through out the world and play an important role in the international trade of electric and electronic products. Moreover, according to the 2005 statistics by the World Bank, the population of countries participating in the IEC activities accounts for 92% of the world total and their trade volume accounts for 95% of the global total.

  4. Standardization in SEK/IEC 2012; Standardisering inom SEK/IEC 2012

    Energy Technology Data Exchange (ETDEWEB)

    Olausson, Susanne

    2013-02-15

    This report describes the work of standardization in the electrotechnical area and collaboration in selected committees of SEK, IEC and CENELEC. Electrotechnical standardization is traditionally an area characterized of large international collaboration, cooperation between government agencies, manufacturers and users. Standardization work has previously been a natural part of power companies' activities related to the extensive expansion activities, own construction business and to generally maintain a good knowledge base of staff. Taking part in the establishment of standards have been a good way to ensure long-term approach made in investments and a guarantee of open competition between manufacturers. Maintenance efforts have also been reduced by using established standards. The acceleration of technological progress has, however, increased pressure on standardization organizations, committee work etc. to keep up with time before the de facto standards have been applied in excessive degree. Reregulation of the electricity market in Sweden has also led to a difference in the standardization process. An increasing number of experts who have worked with standards is currently located at power companies consultancy activities. What was once a natural part of the power companies' internal skills provision today are exposed to a commercial assessment. In 1994 Elforsk was appointed by the owners the task of coordinating the power companies' joint standardization work within specifically electrical engineering. After an initial assessment of the activities was decided that remunera would be paid to the members in SEK, IEC and CENELEC who either participated in selected projects with international character or was either secretary or chairman of the Swedish technical committees (SEK)

  5. Competence Requirements of ISO/IEC Standards for Information Security Professionals

    Directory of Open Access Journals (Sweden)

    Natalia G. Miloslavskaya

    2017-11-01

    Full Text Available The rapid progress in the filed of information security (IS puts one in a need of periodic revision of professional competencies (formulated in the federal state educational standards –FSESs and working functions (formulated in the professional standards – PSs. Under these conditions, a timely reaction to everything new that emerges or will appear in modern regulatory documents (primarily in standards is extremely important. We make a forecast for the content of the ISO/IEC 27021 and ISO/IEC 19896 standards drafted by the International Organization for Standardization (ISO, which should contain the requirements for the competencies of IS management system professionals and the competence of IS testers and evaluators. Our forecast takes into account the requirements of the ISO/IEC 27000 standard group and the recommendations of the European e-Competence Framework e-CF 3.0.

  6. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  7. ISO/IEC 38500 the IT governance standard

    CERN Document Server

    Calder, Alan

    2008-01-01

    The emergence of ISO/IEC 38500 - the international standard for the corporate governance of information and communication technology - puts boards around the world in a position from which they can take effective action to apply core governance principles to their information and communication technology.

  8. Effect of superimposed low frequency oscillations on the static creep behaviour of Al-1 wt%Si and Al-1 wt%Si-0.1 wt%Zr-0.1 wt%Ti alloys

    Energy Technology Data Exchange (ETDEWEB)

    Beshai, M.H.N. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics; Deaf, G.H. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics; Abd El Khalek, A.M. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics; Graiss, G. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics; Kenawy, M.A. [Physics Dept., University Coll. for Women, Ain Shams Univ., Cairo (Egypt)

    1997-05-16

    Torsional oscillations of increasing frequencies with constant torsional strain amplitude, {theta}, of 3.1 x 10{sup -4} were superimposed on wires of Al-1 wt% Si and Al-1 wt% Si-0.1 wt% Zr-0.1 wt% Ti alloys, while being crept under constant stress (52.3 MPa) and different testing temperatures. It was found that increasing the frequency of oscillations resulted in an increase of both transient and steady state creep. In the transient stage, while the exponent n is increasing with frequency v, the parameter {beta} decreases. Zirconium and titanium addition generally reduced the rate of creep. A value of 20 kJ/mol was found for the activation energy of the mechanism operating in the transient and steady state stages which was ascribed as being due to dislocation intersection. (orig.)

  9. Standard IEC 61850 substation automation

    Energy Technology Data Exchange (ETDEWEB)

    Bricchi, A.; Mezzadri, D. [Selta, Tortoreto (Italy)

    2008-07-01

    The International Electrotechnical Commission (IEC) 61850 standard is the reference communication protocol for all electrical substations protection and control systems. It creates models of all the elements and functionalities of an electrical substation, including physical elements such as switches or circuit breakers, as well as protection, control and monitoring functionalities. Network managers need to renew power substation automation and control systems in order to improve the efficiency and quality of services offered by electric utilities. Selta has proposed a new integrated solution for the automation of power substations which is fully compliant with the IEC 61850 norms. The solution involves the integration of control, automation, protection, monitoring and maintenance functions and applies leading edge technology to its systems, particularly for the TERNA network. The system is based on the use of many electronic devices at a power plant, each one with a specialized function, and all interconnected via a Station LAN. This solution, was tested on the TERNA network in Italy, in VHV and HV stations. It was shown to offer many advantages, such as an architecture based on full interoperability between control, monitoring and protection equipment; centralized and distributed automation; a LAN station that allows full interoperability between different bay units and protection relays in order to integrate equipment from various suppliers; the integration of automation systems in existing bay units and protection relays equipped with standard communication buses or with proprietary interfaces; and time synchronization for the entire system through a station GPS reception system. 10 refs., 1 tab., 7 figs.

  10. Thirty years of international nuclear standards in ISO and IEC

    International Nuclear Information System (INIS)

    Becker, K.

    1991-01-01

    Of over 4700 nuclear and radiation protection standards, laws, regulations, recommendations, etc., which have been issued by 52 countries and several governmental international organizations such as IAEA, or non-government organizations such as ICRP, ICRU, ISO and IEC, more than 90% are national, and more than half of those of a non-regulatory nature. Both number and importance of international standards are, however, increasing. The two most important non-governmental international standards organizations are the International Organization for Standardization (ISO), which founded a Technical Committee (TC) 85 'Nuclear Energy' with several Sub-Committees in 1957, and the closely associated International Electrotechnical Commission (IEC) with its TC 45 'Nuclear Instrumentation' formed in 1960. There are over 20 member countries actively participating in the work in each of them, with additional observer countries and liaison to the relevant other international organizations. A brief review is given on some of the experience which has been gained by ISO/TC 85 and IEC/TC 45, and its work program and accomplishments, considering in particular recent developments. It covers nuclear safety and instrumentation, radiation protection, and the nuclear fuel cycle, as well as interface issues including definitions and terminology, interaction of the activities with the work of other national and international bodies, etc. Some problem areas are also briefly discussed. (orig.)

  11. Harmonization of IEEE323 and IEC60780 standards For Environmental Qualificaiton of Electric Equipment

    International Nuclear Information System (INIS)

    Kim, Jong Seog

    2009-01-01

    IEEE323 standard has been widely used for the qualification of electric equipment in Asian pacific area while IEC6070 has been mostly used in European area. Since each plant use different standard for environmental qualification, manufacturer has to perform the qualification test twice in accordance with each standard. Problem also can be happened in the plant site when they are going to purchase equipment qualified by different qualification standard which are not used in his plant. The need of harmonization of each standard has been raised several years and it is known that some studies are in progress by IEEE committee. KEPRI has a plan of comparing EQ relative standards of IEEE, IEC and RCC in 2009. In this paper, brief comparing result between IEEE323 and IEC60780 and the proper harmonization method is introduced

  12. Review and Outlook of China Electronic and IT Industry Footprints in IEC International Standardization Activities

    Institute of Scientific and Technical Information of China (English)

    Hu Jingping

    2006-01-01

    @@ Year 2006 is the year marking the 100th anniversary of the founding of International Electrotechnical Commission (IEC). IEC is mainly engaged in the international standardization for electrical and electronic technology field aiming at promoting international trade and technology cooperation and exchange, improving product and service quality, upgrading productivity and protecting the environment as well as human health and safety. Most countries worldwide adopt standards developed and promulgated by IEC, providing a platform to international trade and technical exchange. China has being a member since 1957. Electronic and IT are the most developed and energetic filed in recent decades. Number of IEC TC/SC specialized in electronic and IT amounts up to 52.

  13. Nuclear Knowledge Capture and IEC Standards

    International Nuclear Information System (INIS)

    Sheldon, J.

    2016-01-01

    Full text: An International Standard is a document, established by consensus and approved by a recognized body that provides, for common and repeated use, rules, guidelines or characteristics for activities or their results, aimed at the achievement of the optimum degree of order in a given context. As such, it is a mechanism for sharing knowledge in a particular field. The consensus process used to approve the content of standards ensures that the content is essentially peer-reviewed. This presentation will explain how International Standards are developed and used and their importance in the dissemination of scientific and engineering information. It will also explain the role of the IEC in ensuring that the process for developing standards meets the core principles of the Code of Good Practice of the WTO TBT agreement: transparency, openness, impartiality and consensus, effectiveness and relevance, coherence, and addressing the concerns of developing countries. (author

  14. IEC 61850 and IEC 62351 Cyber Security Acceleration Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Clements, Samuel L.; Edgar, Thomas W.; Manz, David O.

    2012-04-01

    The purpose of this workshop was to identify and discuss concerns with the use and adoption of IEC 62351 security standard for IEC 61850 compliant control system products. The industry participants discussed performance, interoperability, adoption, challenges, business cases, and future issues.

  15. From IEC 61131 to IEC 61499 for Distributed Systems: A Case Study

    Directory of Open Access Journals (Sweden)

    Christian Gerber

    2008-02-01

    Full Text Available A new concept for distributed control systems based on the new IEC 61499 standard is tested in this work in cooperation with LAE Engineering GmbH, a medium-sized company. Based on a catalogue of requirements, a customer-related testbed is developed. In the following this testbed is used as a reference to realise an IEC 61499 compliant-distributed control system based on PC technics. By doing this, rules are defined to convert user-owned IEC 61131 function blocks to IEC 61499 compliant function blocks. Concluding, some trends for IEC 61499-based distributed control systems will be summarised.

  16. IEC 61850. Integrated supervision of auxiliary power equipment; IEC 61850. Prozess und Eigenbedarf wachsen zusammen

    Energy Technology Data Exchange (ETDEWEB)

    Ostertag, Robert; Jung, Matthias [Siemens AG, Erlangen (Germany)

    2009-07-01

    It is state of technology today: Having process control and auxiliary power control integrated in one DCS. The integration is based on the international standard IEC 61850 which allows standardization of electrical structures from the process interface up to the DCS level. Modern control systems are designed to realize a system structure according to IEC 61850. A wide range of systems is available from systems with interfaces to realize a standardized data exchange up to systems with a complete integration of the standard IEC 61850. (orig.)

  17. Implementation of Electrical Simulation Model for IEC Standard Type-3A Generator

    DEFF Research Database (Denmark)

    Subramanian, Chandrasekaran; Casadei, Domenico; Tani, Angelo

    2013-01-01

    This paper describes the implementation of electrical simulation model for IEC 61400-27-1 standard Type-3A generator. A general overview of the different wind electric generators(WEG) types are given and the main focused on Type-3A WEG standard models, namely a model for a variable speed wind tur...

  18. ISO/IEC 17025 laboratory accreditation of NRC Acoustical Standards Program

    Science.gov (United States)

    Wong, George S. K.; Wu, Lixue; Hanes, Peter; Ohm, Won-Suk

    2004-05-01

    Experience gained during the external accreditation of the Acoustical Standards Program at the Institute for National Measurement Standards of the National Research Council is discussed. Some highlights include the preparation of documents for calibration procedures, control documents with attention to reducing future paper work and the need to maintain documentation or paper trails to satisfy the external assessors. General recommendations will be given for laboratories that are contemplating an external audit in accordance to the requirements of ISO/IEC 17025.

  19. Comparison of IEEE383-2003 and IEC60505-2004 standards for harmonization of environmental qualification procedure of electric cable

    International Nuclear Information System (INIS)

    Kim, Jong Seog; Jeong, Sun Chul; Park, Kyung Heum; Jang, Kyung Nam

    2010-01-01

    Needs for harmonization of international equipment qualification(EQ) standards have been raised several years due to purchasing problem of nuclear equipment supplied from abroad country. To meet the regulatory requirement of domestic nuclear power plant, manufacturers have to qualify their equipment in accordance with each standard such as IEEE, IEC and RCC-E. Double qualification increase the equipment cost, which result in high construction cost. Even the unification of each standard have been discussed several years, we have got the long way to go yet. Comparison and harmonization of each international standard will give help to purchase the equipment qualified by not endorsed standard. Environmental qualification, seismic qualification and EMI/EMC qualification are major targets for harmonization. Since concern about cable qualification of 60 years life has been raised recently, harmonization of cable qualification standard also needs to be discussed. KEPRI launched a project for harmonization of EQ relative standards such as IEEE, IEC and RCC-E. A study for harmonization of IEEE323 and IEC60780 is known in progress by IEEE committee. In this paper, harmonization of international standards for cable qualification will be discussed. IEEE383 standard is qualification standard for electric cable broadly used in Asian pacific area while IEC60505 is mostly used in European area. Since these two standards have different requirements for environmental qualification of cable, problem can be happened in the plant site when they purchase cable qualified by not endorsed standard. IEEE383-2003 and IEC60505-2004 is the latest version of each standard. Comparison results and recommendations for harmonization of these two standards are introduced herein

  20. IEC 61850: integrating substation automation into the power plant control system; IEC 61850: Integration der Schaltanlagenautomatisierung in die Kraftwerksleittechnik

    Energy Technology Data Exchange (ETDEWEB)

    Orth, J. [ABB AG, Mannheim (Germany)

    2008-07-01

    The new communication standard IEC 61850 has been developed in the substation automation domain and was released 2004 as a worldwide standard. Meanwhile IEC 61850 is already established in many substation automation markets. The paper discusses the implementation of IEC 61850 integrating process control and substation automation into one consistent system in a power plant. (orig.)

  1. Comparison and Analysis of IEEE 344 and IEC 60980 standards for harmonization of seismic qualification of safety-related equipment

    International Nuclear Information System (INIS)

    Lee, Young Ok; Kim, Jong Seog; Seo, Jeong Ho; Kim, Myung Jun

    2011-01-01

    The seismic qualification of safety related equipment in nuclear power plants should demonstrate an equipment's ability to perform its safety function during/or after the time it is subjected to the forces resulting from one SSE. In addition, the equipment must withstand the effects of a number of OBEs, preceding the SSE. IEEE 344 and IEC 60980 present the criteria for establishing procedures demonstrating that the Class 1E equipment can meet its performance requirement during seismic events. Currently, IEEE 344 is used for regulation of nuclear power plant in the United State whereas IEC 60980 is mainly used in Europe. In particular, NPPs of France and China apply with RCC-E and GB that are domestic standards, respectively. Equipment supplier and Utility have difficulties because of different applicable standards. Equipment supplier to export S/R components/equipment to other standard area performs additional seismic qualification. For example, equipment are qualifies according to IEC 60980, RCC-E, GB although they have been qualified in accordance with IEEE 344. Also, utility to attempt power up-rate, life extension of NPP constructed under rules of RCC-E such as Ulchin NPP 1 and 2 has similar difficulties. RCC-E endorses IEC 60980 and GB is almost same as IEC 60980 except minor difference of earthquake environment definition. Therefore this paper surveys the similarities and differences between IEEE 344 and IEC 60980. In addition, this paper considers how the two sets of standards may be used in a complementary fashion to be possible using one or the other standard area

  2. Leveraging Software Architectures through the ISO/IEC 42010 standard: A Feasibility Study

    NARCIS (Netherlands)

    Tamburri, D.A.; Lago, P.; Muccini, H.; Proper, E.; Lankhorst, M.; Schoenherr, M.

    2011-01-01

    The state of the practice in enterprise and software architecture learnt that relevant architectural aspects should be illustrated in multiple views, targeting the various concerns of different stakeholders. This has been expressed a.o. in the ISO/IEC 42010 Standard on architecture descriptions. In

  3. IEC Newsletter, No. 53/3 (2015)

    International Nuclear Information System (INIS)

    2015-12-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. The following topics are presented in this newsletter: Prepared to Respond International Conference on Global EPR; Launch of EPRIMS; First meeting of EPR Standards Committee; IEC and French experts test assessment and prognosis arrangements; IEC and Swiss counterparts conduct an assessment and prognosis drill; Consultancy on CANDUspecific EALs; Regional Workshops; Recently reported events; Member State preparedness; IEC welcomes young visitors on Bring Your Children to Work day

  4. Steady state creep during metastable phase transition in Al-16 wt% Ag and Al-16 wt% Ag-0.1 wt% Zr alloys

    Energy Technology Data Exchange (ETDEWEB)

    Deaf, G.H.; Youssef, S.B.; Mahmoud, M.A. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics

    1998-08-16

    The early stages of decomposition of Guinier-Preston zones (G.P. zones) in Al-16 wt% Ag and Al-16 wt% Ag-0.1 wt% Zr alloys were investigated through creep measurements and electron microscopy observations. It was found that the strengthening and softening of the alloys has been achieved during the formation of metastable phases (G.P. zones and {gamma}`-phase) in the ageing temperature range (428 to 498 K). TEM investigations confirmed that the addition of zirconium to the Al-Ag alloy accelerates the formation and coarsening of the metastable phases. The mean values of activation energy of both alloys were found to be equal to that quoted for precipitate-dislocation interactions. (orig.) 23 refs.

  5. Characterization and standardized radiation qualities deployment - NBR IEC 61225 - in a animal irradiator

    International Nuclear Information System (INIS)

    Carvalho, Samara; Magalhaes, Luis Alexandre Goncalves

    2015-01-01

    The present work consisted in the determination of additional aluminum filters, so that the Animal Irradiator of the Laboratory of Radiological Sciences-UERJ can operate in accordance with standard IEC 61267: 2005. In order to perform the measurements necessary for the determination of these filters, it was developed an additional filter positioning system coupled to the X-ray tube. The determination of these filters was performed to obtain the first half value layer (HVL) according to the window with the values given by the IEC 61267: 2005. It was used IPEN SRS-78 (Institute of Physics and Engineering in Medicine) software for the estimation of the total amount of the additional filtration through the measurements values of the first HVL. (author)

  6. Wind Plant Models in IEC 61400-27-2 and WECC - latest developments in international standards on wind turbine and wind plant modeling

    DEFF Research Database (Denmark)

    Fortmann, Jens; Miller, Nicholas; Kazachkov, Yuri

    2015-01-01

    This paper describes the latest developments in the standardization of wind plant and wind plant controller models. As a first step IEC TC88 WG 27 and WECC jointly developed generic wind turbine models which have been published by WECC in 2014 and IEC in 2015 as IEC 61400-27-1, which also include...

  7. Information security in accordance with ISO/IEC 27000

    OpenAIRE

    Košćak , Damjan

    2011-01-01

    The diploma assignment discusses Information Technology Security according to standards ISO/IEC 27001 and ISO/IEC 27002. Diploma consists of two parts. In the first part of the diploma a theoretical bases of information security are presented. The second part presents the introduction of ISO/IEC 27001 security standard in the company »X« in wich I performed a practical training. In the closure my diploma work is upgraded with results of my research work and their analysis as well as wit...

  8. Safety critical systems handbook a straightforward guide to functional safety : IEC 61508 (2010 edition) and related standards

    CERN Document Server

    Smith, David J

    2010-01-01

    Electrical, electronic and programmable electronic systems increasingly carry out safety functions to guard workers and the public against injury or death and the environment against pollution. The international functional safety standard IEC 61508 was revised in 2010, and this is the first comprehensive guide available to the revised standard. As functional safety is applicable to many industries, this book will have a wide readership beyond the chemical and process sector, including oil and gas, power generation, nuclear, aircraft, and automotive industries, plus project, instrumentation, design, and control engineers. * The only comprehensive guide to IEC 61508, updated to cover the 2010 amendments, that will ensure engineers are compliant with the latest process safety systems design and operation standards* Helps readers understand the process required to apply safety critical systems standards* Real-world approach helps users to interpret the standard, with case studies and best practice design examples...

  9. The IEC-publication 336/1981 - new formulation of the standards for X-ray foci

    International Nuclear Information System (INIS)

    Geldner, E.; Schnitger, H.

    1982-01-01

    With the new IEC-standard for foci a clear distinction has been made between application oriented focus classification, expressed by the focus nominal value as a dimensionless number and the detectable real geometric focus measured in the sense of the principle 'Truth in advertising'. Now, even regions of a size [de

  10. The role of the IEC and ISO in radiological protection

    International Nuclear Information System (INIS)

    White, D.F.

    1976-01-01

    The history, objectives, structures and functions of the International Electrotechnical Commission (IEC) and the International Organisation for Standardisation (ISO) are summarized. The IEC is affiliated to the ISO as its electrical division, but has technical and financial autonomy. Member countries of the EEC may be committed to the adoption of their formal agreements ('Standards') if these become incorporated as Directives. The national standardisation organisations, such as BSI in the U.K., form national committees and are responsible for submitting to the IEC the co-ordinated national viewpoints on particular subjects. The overall links between the technical committees and sub-committees of the ISO, IEC and BSI in the field of radiological protection are tabulated, and the relevant International Standards produced, or in the course of preparation, by the appropriate committees of the ISO and the IEC are listed. The bulk of the effort of the BSI committees is now aimed at the production of acceptable international standards. Compatible national standards then follow. This policy is in contrast to the earlier initial emphasis on national standards, and the improved international collaboration has had two welcome effects. The selection of proposals for standards is more critical, and compatibility with the relevant ICRP and ICRU publications is almost a prerequisite for any international standard. (U.K.)

  11. IEC Newsletter, No. 51, First Quarter, 2015

    International Nuclear Information System (INIS)

    2015-06-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. The following topics are presented in this newsletter: IEM 8; Internal Full Response Exercise; Board of Governors establishes Safety Requirements in EPR as IAEA Safety Standard; ConvEx-2a; EURDEP Meeting; Train the Trainers Workshop on Medical Aspects of EPR; EPR-Medical 2005 Review Process; EPRIMS; Member State Preparedeness; EPREV Mission to Kenya; RENEB Meeting; Update by Finland of its RANET registration; Recent Events; Upgraded IEC videoconferencing infrastracture; EPREG Meeting and Forthcoming Event: EPR Conference

  12. On the Implementation of the IEC 61850 Standard: Will Different Manufacturer Devices Behave Similarly under Identical Conditions?

    Directory of Open Access Journals (Sweden)

    Mohamad El Hariri

    2016-12-01

    Full Text Available Standardization in smart grid communications is necessary to facilitate complex operations of modern power system functions. However, the strong coupling between the cyber and physical domains of the contemporary grid exposes the system to vulnerabilities and thus places more burden on standards’ developers. As such, standards need to be continuously assessed for reliability and are expected to be implemented properly on field devices. However, the actual implementation of common standards varies between vendors, which may lead to different behaviors of the devices even if present under similar conditions. The work in this paper tested the implementation of the International Electro-technical Commission’s Generic Object Oriented Substation Event GOOSE (IEC 61850 GOOSE messaging protocol on commercial Intelligent Electronic Devices (IEDs and the open source libiec61850 library—also used in commercial devices—which showed different behaviors in identical situations. Based on the test results and analysis of some features of the IEC 61850 GOOSE protocol itself, this paper proposes guidelines and recommendations for proper implementation of the standard functionalities.

  13. Implementation of IEC standard models for power system stability studies

    Energy Technology Data Exchange (ETDEWEB)

    Margaris, Ioannis D.; Hansen, Anca D.; Soerensen, Poul [Technical Univ. of Denmark, Roskilde (Denmark). Dept. of Wind Energy; Bech, John; Andresen, Bjoern [Siemens Wind Power A/S, Brande (Denmark)

    2012-07-01

    This paper presents the implementation of the generic wind turbine generator (WTG) electrical simulation models proposed in the IEC 61400-27 standard which is currently in preparation. A general overview of the different WTG types is given while the main focus is on Type 4B WTG standard model, namely a model for a variable speed wind turbine with full scale power converter WTG including a 2-mass mechanical model. The generic models for fixed and variable speed WTGs models are suitable for fundamental frequency positive sequence response simulations during short events in the power system such as voltage dips. The general configuration of the models is presented and discussed; model implementation in the simulation software platform DIgSILENT PowerFactory is presented in order to illustrate the range of applicability of the generic models under discussion. A typical voltage dip is simulated and results from the basic electrical variables of the WTG are presented and discussed. (orig.)

  14. Implementation of the OECD principles of good laboratory practice in test facilities complying with a quality system accredited to the ISO/IEC 17025 standard.

    Science.gov (United States)

    Feller, Etty

    2008-01-01

    Laboratories with a quality system accredited to the ISO/IEC 17025 standard have a definite advantage, compared to non-accredited laboratories, when preparing their facilities for the implementation of the principles of good laboratory practice (GLP) of the Organisation for Economic Co-operation and Development (OECD). Accredited laboratories have an established quality system covering the administrative and technical issues specified in the standard. The similarities and differences between the ISO/IEC 17025 standard and the OECD principles of GLP are compared and discussed.

  15. Jefferson Lab IEC 61508/61511 Safety PLC Based Safety System

    International Nuclear Information System (INIS)

    Mahoney, Kelly; Robertson, Henry

    2009-01-01

    This paper describes the design of the new 12 GeV Upgrade Personnel Safety System (PSS) at the Thomas Jefferson National Accelerator Facility (TJNAF). The new PSS design is based on the implementation of systems designed to meet international standards IEC61508 and IEC 61511 for programmable safety systems. In order to meet the IEC standards, TJNAF engineers evaluated several SIL 3 Safety PLCs before deciding on an optimal architecture. In addition to hardware considerations, software quality standards and practices must also be considered. Finally, we will discuss R and D that may lead to both high safety reliability and high machine availability that may be applicable to future accelerators such as the ILC.

  16. Effect of Pre-Aging Conditions on Bake-Hardening Response of Al-0.4 wt%Mg-1.2 wt%Si-0.1 wt%Mn Alloy Sheets

    International Nuclear Information System (INIS)

    Lee, Kwang-jin; Woo, Kee-do

    2011-01-01

    Pre-aging heat treatment after solution heat treatment (SHT) of Al-0.4 wt%Mg-1.2 wt%Si-0.1 wt%Mn alloy sheets for auto-bodies was carried out to investigate the effect of pre-aging and its conditions on the bake-hardening response. Mechanical properties were evaluated by a tensile and Vickers hardness test. Microstructural observation was also performed using a transmission electron microscope (TEM). It was revealed that pre-aging treatments play a great role in the bake-hardening response. In addition, it was found that the sphere-shaped nanosized clusters that can directly transit to the needle-shaped β” phase during the paint-bake process, not being dissolved into the matrix, are formed at 343 K. The result, reveals that the dominant factor of the bake-hardening response is the pre-aging temperature rather than the pre-aging time.

  17. IEC Newsletter, No. 52/2 (2015)

    International Nuclear Information System (INIS)

    2015-10-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. The following topics are presented in this newsletter: Peer Review of UAE’s Emergency Plans for Barakah NPP; IEM 9: Assessment and Prognosis in Response to a Nuclear or Radiological Emergency; Tabletop exercise simulating marime transport emergency; Establishment of EPR Standards Committee; Annual ConvEx-1c; Advisory Mission to Kuwait on medical aspects of EPR; EPR self-assessment for Arab Member States; Event at Cattenom NPP; Train the Trainers Workshop for first responders in Vienna; Member States Preparedness; Republic of Korea joins RANET — USA registers new capabilities; Workshop on Emergency Radiation Monitoring; #EPR15: International Conference on Global EPR; Recent Events

  18. Influence of Macro-Topography on Damage Tolerance and Fracture Toughness of 0.1 wt % Multi-Layer Graphene/Clay-Epoxy Nanocomposites

    Directory of Open Access Journals (Sweden)

    Rasheed Atif

    2016-07-01

    Full Text Available Influence of topographical features on mechanical properties of 0.1 wt % Multi-Layer Graphene (MLG/clay-epoxy nanocomposites has been studied. Three different compositions were made: (1 0.1 wt % MLG-EP; (2 0.1 wt % clay-EP and (3 0.05 wt % MLG-0.05 wt % clay-EP. The objective of making hybrid nanocomposites was to determine whether synergistic effects are prominent at low weight fraction of 0.1 wt % causing an improvement in mechanical properties. The topographical features studied include waviness (Wa, roughness average (Ra, root mean square value (Rq and maximum roughness height (Rmax or Rz. The Rz of as-cast 0.1 wt % MLG-EP, clay-EP and 0.05 wt % MLG-0.05 wt % clay-EP nanocomposites were 43.52, 48.43 and 41.8 µm respectively. A decrease in Rz values was observed by treating the samples with velvet cloth and abrasive paper 1200P while increased by treating with abrasive papers 320P and 60P. A weight loss of up to 16% was observed in samples after the treatment with the abrasive papers. It was observed that MLG is more effective in improving the mechanical properties of epoxy than nanoclay. In addition, no significant improvement in mechanical properties was observed in hybrid nanocomposites indicating that 0.1 wt % is not sufficient to generate conspicuous synergistic effects.

  19. Accreditation - ISO/IEC 17025

    Science.gov (United States)

    Kaus, Rüdiger

    This chapter gives the background on the accreditation of testing and calibration laboratories according to ISO/IEC 17025 and sets out the requirements of this international standard. ISO 15189 describes similar requirements especially tailored for medical laboratories. Because of these similarities ISO 15189 is not separately mentioned throughout this lecture.

  20. Interpretation of MS ISO/ IEC 17020

    International Nuclear Information System (INIS)

    Mohamad Pauzi Ismail

    2012-01-01

    MS ISO/ IEC 17020 is an international standard which adopted by Malaysian Standard states the requirement criteria for inspection bodies. The author involved in the NDT technical assessment to several NDT companies in Malaysia. The experience in performing NDT assessment activity is explained and discussed. (author)

  1. Power system EMC and IEC publication 1000

    International Nuclear Information System (INIS)

    Teichmann, H.

    1997-01-01

    A classification of the principal phenomena causing electromagnetic disturbances has been prepared by the International Electrotechnical Commission (IEC). Electromagnetic compatibility was defined (by the IEC) as 'the ability of a device, equipment or system to function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetic disturbances in that environment'. The classification includes the following phenomena relative to power systems: (1) low-frequency phenomena, (2) radiated low-frequency phenomena, (2) conducted high-frequency phenomena, (3) radiated high-frequency phenomena, and (4) electrostatic discharge phenomena. The structure of the IEC publication 1000 was explained. Parts 1, 2, 3 and 6 of the publication were highlighted. The issues covered in those parts were: (Part 1) general, (Part 2) environment, (Part 3) limits, and (Part 6) generic standards. 6 refs

  2. Progress in IEC 61400-27

    DEFF Research Database (Denmark)

    Sørensen, Poul Ejnar; Andresen, Björn; Bech, John

    2012-01-01

    turbines (part 1) and wind power plants (part 2), which are intended for short-term power system stability analyses. WG27 submitted the first CD of Part 1 in December 2012. The CD describes generic wind turbine models and a procedure for validation of wind turbine models. The generic model description......This paper presents the status of the ongoing work in IEC Technical Committee 88 Working Group 27 (TC88 WG27) developing a standard IEC 61400-27 for “Electrical simulation models for wind power generation”. The purpose of this standardization work is to define generic simulation models for wind...... consists of a general model structure intending to cover existing as well as future types of wind turbines, and specific fundamental frequency positive sequence models for the four wind turbine types which are widely used today. The validation procedure can be applied to the generic models specified...

  3. TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

    International Nuclear Information System (INIS)

    Supanich, M.

    2015-01-01

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists

  4. TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

    Energy Technology Data Exchange (ETDEWEB)

    Supanich, M. [Rush University Medical Center (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  5. Information security for energy automation. IEC 62351 Challenges and possible solutions; Informationsicherheit fuer die Energieautomatisierung. IEC 62351 - Herausforderungen und Loesungsansaetze

    Energy Technology Data Exchange (ETDEWEB)

    Knorr, K.; Fries, S. [Sector Corporate Technology, Siemens AG, Muenchen (Germany); Seewald, M.G. [Sector Energy, Siemens AG, Nuernberg (Germany)

    2008-10-06

    Information security has gained tremendous importance for energy automation systems over the last years. New standards like IEC 62351 address this topic and specify technical requirements which have to be met by the vendors. Especially vendors that cover the entire energy automation chain with their product portfolio have to face several new demanding challenges. The authors describe suitable approaches and implementation issues that are derived from selected IEC 62351 requirements following the product lifecycle process. (orig.)

  6. X radiation qualities characterization following the standard IEC 61267 recommendations at the calibration laboratory of IPEN

    International Nuclear Information System (INIS)

    Franciscatto, Priscila Cerutti

    2009-01-01

    This work presents a methodology for the X radiation qualities characterization following the new recommendations of the standard 61267 of the International Electrotechnical Commission (IEC) to establish a new procedure for calibration of dosimetric systems used in the field of diagnostic radiology. The reference qualities radiation of IEC 61267: RQR 2 to RQR 10, RQA 2 to RQA 10, RQB 2 to RQB 10 and RQN 2 to RQN 10 were implanted at the calibration laboratory of IPEN (LCI). Their characteristics were analyzed through measurements of beam parameters such as: Practical peak voltage (PPV), specific additional filtrations for each qualities (high purity aluminum of about 99.9%), 1st and 2nd Half Value Layers, homogeneity coefficient. The inherent filtration of the X ray tube was also determined. With the establishment of these radiation qualities, the LCI will be ready to calibrate the measuring instruments of radiation in the new qualities, allowing an improvement in radiological services offered by IPEN. (author)

  7. Using the IEC Standard to Describe Low-Background Detectors-What Can You Expect?

    International Nuclear Information System (INIS)

    Ronald M. Keyser; Sanford Wagner

    1998-01-01

    The new International Electrotechnical Commission (IEC) standard for describing the background makes the specification of the background in a high-purity germanium (HPGe) detector simple, unambiguous, and related to how the detector will be used. Users and manufacturers will finally be speaking the same language on this subject. Because this standard extends the specification of the performance of an HPGe detector, there is little history available for comparison and thus no means of determining a ''good'' value. To develop a history, the background spectrum for 500 low-background HPGe ORTEC detectors were all counted in similar low-background shields. These detectors were in a variety of mechanical cryostat and endcap configurations. The continuum background is a function of energy and detector size/configuration. The peak area for the peak energies listed in the standard is a function of detector size and configuration. The results thus give practical guidance for obtaining the most appropriate low-background detector for a specific measurement problem

  8. Qualification of a Human-System Interface to Meet IEC 61513

    International Nuclear Information System (INIS)

    Malcom, Scott; Kim, Sun Ho; Macdonald, Marienna

    2011-01-01

    This paper describes the steps Atomic Energy of Canada Limited (AECL TM ) undertook to qualify its Advanced Control Centre Information System (ACCIS TM ) to meet the requirements of IEC 61513. It will address the different strategies used for software versus hardware. As well, the paper will discuss the steps that have been taken to qualify third-party commercial-off-the-shelf products that are used in conjunction with a qualified product. ACCIS is a display, monitoring and supervisory control system that is designed to be readily configurable and scalable to satisfy the display requirements for single functions or complex industrial plant systems. The ACCIS software services are configured and deployed across a distributed computing environment to meet the needs of a given implementation. From small single-node applications to large, complex, multi-node configurations, system behaviour is largely configured via data specifications. This design reduces the costs associated with development of custom software and allows the user to have greater control of behavioral attributes of the system, including data sampling and storage rates, the appearance and behaviour of displays, alarm annunciation features, and the configuration of system health checks. Utilities and regulators are demanding that these computer-based systems are developed and maintained with an appropriate amount of engineering rigor. To meet this challenge, AECL is qualifying its ACCIS HSI, which is intended for use in all future CANada Nuclear Deuterium (CANDU TM ) nuclear power plants, to meet the requirements of the International Electrotechnical Commission's (IEC) standard for instrumentation and control systems important to safety, IEC 61513. Transitioning to the IEC standards has not been without its challenges. While AECL previously used a software development model very similar to the IEC model, absorbing the volume of the IEC standards and understanding how they should be applied has been

  9. Understanding IEC standard wind turbine models using SimPowerSystems

    DEFF Research Database (Denmark)

    Das, Kaushik; Hansen, Anca Daniela; Sørensen, Poul Ejnar

    2016-01-01

    This article describes and exemplifies the IEC 61400-27 generic wind turbine models through an interactive multimedia learning environment - Matlab SimPowerSystems. The article aims help engineers with different backgrounds to get a better understanding of wind turbine dynamics and control...

  10. Upgrading the Medical Physics Calibration Laboratory Towards ISO/IEC 17025: Radiation Standards and Calibration in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Muhammad Jamal Md Isa; Abd Aziz Mhd Ramli; Wan Hazlinda Ismail; Norhayati Abdullah; Shahrul Azlan Azizan; Siti Sara Deraman; Nor Azlin Azraai; Md Khairusalih Md Zin

    2010-01-01

    Calibration of quality control (QC) test tools used in diagnostic radiology is legally required under the Ministry of Health (MOH) requirement. The Medical Physics Calibration Laboratory of the Malaysian Nuclear Agency is the national focal point for the calibration of quality control test tools used in diagnostic radiology. The Medical Physics Calibration Laboratory has measurement traceability to primary standard dosimetry laboratory (Physikalisch-Technische Bundesanstalt (PTB)), thus providing an interface between the primary standard dosimetry laboratory and Malaysian hospitals, clinics and license class H holder. The Medical Physics Calibration Laboratory facility is comprised of a constant potential x-ray system with a capability of 160 kV tube and a series of reference and working standard ion chambers. The stability of reference and working standard ion chambers was measured using strontium-90. Dosimetric instruments used in diagnostic radiology is calibrated in terms of air kerma to comply with an International Code of Practices of dosimetry for example IAEA's Technical Report Series number 457. The new series of standard radiation qualities was established based on ISO/IEC 61267. The measurement of beam homogeneity was measured using film and ion chamber to define the field size at certain distance and kV output was measured using the spectrometer and non-invasive kVp meter. The uncertainties measurement was determined with expended uncertainties to a level of confidence of approximately 95% (coverage factor k=2). This paper describes the available facility and the effort of the Medical Physics Calibration Laboratory to upgrade the laboratory towards ISO/IEC 17025. (author)

  11. ITIL and ISO/IEC 20000 a practical handbook

    CERN Document Server

    Hernandez, Alex

    2012-01-01

    The purpose of this publication is to provide your organization with a pragmatic approach to effectively implementing service management, incorporating practices from the ITIL framework and the ISO/IEC 20000 standard.

  12. The common information model CIM IEC 61968/61970 and 62325 : a practical introduction to the CIM

    CERN Document Server

    Uslar, Mathias; Rohjans, Sebastian; Trefke, Jörn; Vasquez Gonzalez, Jose Manuel

    2012-01-01

    Within the Smart Grid, the combination of automation equipment, communication technology and IT is crucial. Interoperability of devices and systems can be seen as the key enabler of smart grids. Therefore, international initiatives have been started in order to identify interoperability core standards for Smart Grids.   IEC 62357, the so called Seamless Integration Architecture, is one of these very core standards, which has been identified by recent Smart Grid initiatives and roadmaps to be essential for building and managing intelligent power systems. The Seamless Integration Architecture provides an overview of the interoperability and relations between further standards from IEC TC 57 like the IEC 61970/61968: Common Information Model - CIM.   CIM has proven to be a mature standard for interoperability and engineering; consequently, it is a cornerstone of the IEC Smart Grid Standardization Roadmap. This book provides an overview on how the CIM developed, in which international projects and roadmaps is h...

  13. TU-G-213-00: The International Electrotechnical Commission (IEC): What Is It and Why Should Medical Physicists Care?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  14. A multi-function IEC 61850 packet generator based on FPGA

    International Nuclear Information System (INIS)

    Wei, Wei; Li, Hong-bin; Cheng, Han-miao

    2016-01-01

    An IEC 61850 packet generator is used to produce IEC 61850-9-2 packets by simulating the merging unit and testing the IEC 61850 digital device. While the existing IEC packet generator can produce ideal digital without any noise, it does not take into account the fact that the merging unit output signal packets will be inevitably superimposed with noise. Since the International Electrical Commission standard of the electronic current transformer specifies the minimum output signal-to-noise ratio of the merging unit to be 30 dB, and the signal superimposed with noise will influence the operation performance of the digital device, it is necessary to design a multi-function IEC 61850-9-2 packet generator for a digital device test. Therefore, in this paper, a multi-function IEC 61850 packet generator has been developed, which not only can output various IEC 61850-9-2 packets, but also can add white Gaussian noise to the signal for digital device testing. By testing three digital electricity meters from different manufacturers, we showed that the error of the digital electricity meter is significantly larger when the signal packet is superimposed with noise. Also when the signal-to-noise ration is 30 dB, the error of one of the meters exceeds the allowed range of the accuracy class. This indicates that the noise testing and the noise setting function of the system has an important role in the testing of a digital device. (paper)

  15. Adopting ISO 9712:2005 and ISO/IEC 17024:2003 as Philippine national standard for NDT for global competitiveness

    International Nuclear Information System (INIS)

    Banaga, Renato T.; Mateo, Alejandro J.

    2005-01-01

    This paper describes and promotes the adoption of ISO 9712: 2005 edition and the ISO/IEC 17024: 2003 edition by the Philippines to be globally competitive. ISO 9712 is a standard for qualifications and certification of nondestructive testing (NDT) personnel while ISO/IEC 17024 is conformity assessment-general requirements for bodies operating certification of persons. ISO 9712 defies that the effectiveness of an application of nondestructive testing depends on the capabilities and qualifications of personnel performing the NDT test. The Philippines through the national certifying body (NCB) implements the certification of proficiency of NDT personnel in accordance with the Philippine National Standards (PNS-146: 1998) This standard (formerly PNS-146: 1987) was originally based from the draft ISO/TC-135/SC7N35.3 and was later revised to conform to the latest ISO FDIS 9712: 1997 and rename PNS-146: 1998. Now with the issuance of the latest ISO 9712:2005 edition and to keep abreast with the current trends of NDT technology, present time and conditions dictates for us to revise our NDT personnel certification to the latest edition of ISO 9712. The International Atomic Energy Agency (IAEA) supports the establishment of a common NDT standard. The IAEA is promoting af financially supporting the establishment in developing countries of only one NDT standard. The IAEA through the Regional Cooperative Agreement (RCA) has initiated the harmonization of the NDT qualification and certification of personnel in the RCA member states. In October 2001, the IAEA sponsored the Dhaka meeting where the International Committee for Nondestructive Testing (ICNDT), Asia-Pacific Committee (APCNDT) and RCA member states representatives drafted a Mutual Recognition Agreement (MRA) for the Asia-Pacific NDT (APCNDT) personnel certification schemes acording to ISO 9712. Last August 2005, IAEA/RCA sponsored the Colombo meeting for the harmonization of regional NDT applying ISO 9712 and ISO/IEC

  16. Evaluation of the central libraries information security management at governmental universities located in Tehran, according to the international standard ISO/IEC 27002

    Directory of Open Access Journals (Sweden)

    Milad Malekolkalami

    2014-02-01

    Full Text Available This study assessed the evaluation of information security management status in central Libraries of governmental universities located in Tehran, according to ISO / I.E.C. 27002. Research method applied for the study is descriptive Survey and a questionnaire was used for collecting information. The questionnaire was distributed between the 74 central library managers of governmental universities in Tehran according to the recent list on the website of Ministry of Science, Research and Technology, that includes 39 components based on 11 indicators of the standard ISO/ I.E.C. 27002. Analysis of data has been done by using both descriptive and inferential statistics by Microsoft Excel 2007and SPSS statistical softwares. The results of research showed that the mean for libraries in 11 indexes are as follows: The mean for the first index, Security policy, is 3.91 , in the second index, organization of information security, is 4.23, in the third index, asset security management, is 4.38, in the fourth index, Human Resources Security management, is 4, in the fifth index, physical and environment Security management, is 4.07, in the sixth index, operations management and communications, is 4.15, in the Seventh index, access controls management, is 4.38, in the eighth index, information system acquisition, development and maintenance, is 3.92, in the ninth index, information security incident management, is 3.84, in the tenth index, business continuity management, is 3.46, in the eleventh index, compliance, is 3.69 that match with the standard ISO / IEC. 27002. The results of Research shown that totally mean for standard ISO/I.E.C. 27002 in the field of information security management in the central libraries, is 4 being in a good condition and there is no significant differences between the performance of the Central libraries of the governmental Universities in Tehran, since It is not observed significant difference between them in the field of

  17. Modelling of plug and play interface for energy router based on IEC61850

    Science.gov (United States)

    Shi, Y. F.; Yang, F.; Gan, L.; He, H. L.

    2017-11-01

    Under the background of the “Internet Plus”, as the energy internet infrastructure equipment, energy router will be widely developed. The IEC61850 standard is the only universal standard in the field of power system automation which realizes the standardization of engineering operation of intelligent substation. To eliminate the lack of International unified standard for communication of energy router, this paper proposes to apply IEC61850 to plug and play interface and establishes the plug and play interface information model and information transfer services. This paper provides a research approach for the establishment of energy router communication standards, and promotes the development of energy router.

  18. Effect of strain on evolution of dynamic recrystallization in Nb-1 wt%Zr-0.1 wt%C alloy at 1500 and 1600 °C

    Energy Technology Data Exchange (ETDEWEB)

    Behera, A.N. [Mechanical Metallurgy Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Homi Bhabha National Institute, Anushakti Nagar, Mumbai 400094 (India); Kapoor, R., E-mail: rkapoor@barc.gov.in [Mechanical Metallurgy Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Homi Bhabha National Institute, Anushakti Nagar, Mumbai 400094 (India); Paul, B. [Materials Processing & Corrosion Engineering Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Chakravartty, J.K. [Mechanical Metallurgy Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2017-04-15

    Uniaxial compression tests were carried out on Nb-1 wt%Zr-0.1 wt%C alloy at temperature of 1500 and 1600 °C and strain rate of 0.1 s{sup −1} to study the evolution of dynamic recrystallization with strain. Electron back scatter diffraction was used to quantify the microstructural evolution. Nb-1Zr-0.1C alloy showed a necklace structure at a strain of 0.9 when deformed at 1500 °C and at strain of 0.6 when deformed at 1600 °C, both at strain rate of 0.1 s{sup −1}. This suggested the occurrence of dynamic recrystallization. At 1500 °C and strain of 0.9 the local average misorientation and the grain orientation spread was low confirming the presence of dynamic recrystallization at this deformation condition. At both 1500 and 1600 °C and all measured strains the recrystallized grains had a strong fiber component of <001>. - Highlights: • Necklace formation of dynamically recrystallized grains occurred at strain of 0.6 and 0.9 for 1500 and 1600 °C, respectively. • Equiaxed microstructures were seen with increase in strain for both 1500 and 1600 °C. • At large strains the predominant recrystallized texture evolved to <001> pole.

  19. A primer on the Petri Net Markup Language and ISO/IEC 15909-2

    DEFF Research Database (Denmark)

    Hillah, L. M.; Kindler, Ekkart; Kordon, F.

    2009-01-01

    Standard, defines a transfer format for high-level nets. The transfer format defined in Part 2 of ISO/IEC 15909 is (or is based on) the \\emph{Petri Net Markup Language} (PNML), which was originally introduced as an interchange format for different kinds of Petri nets. In ISO/IEC 15909-2, however...

  20. Prototype of generic server for wind power plants using IEC 61400-25 standard

    DEFF Research Database (Denmark)

    Olsen, Andreas K.; Ösdil, B.; Poulsen, Bjarne

    2006-01-01

    from interfaces for control and monitoring to a standardized and secure way of handling communication. An analysis focusing on isolating the necessary requirements has been carried out based on the IEC61400-25 in order to create a generic prototype which can be used by WPP vendors. The main...... communications interface of the prototype utilizes web services and the prototype developed is comprised of several independent modules to allow for the possibility of choosing a fully customizable setup by the end user. Configuration of the system needs to be done in a simple way, ensuring a flexible...... and reusable system, where different choices for the system can be added or left out depending on user specifications. From the requirements a prototype with the purpose of examining the key aspects of these definitions has been elaborated....

  1. IEC Newsletter, No. 49, Third Quarter 2014

    International Nuclear Information System (INIS)

    2014-12-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. Table of contents: • Spolighting IEC Activities at the 58th IAEA General Conference; • TM on Lessons Learned from Past Emergency Preparedness Review (EPREV) Missions; • Third Full Response Exercise of 2014; • Israel joins RANET; • Launch of Emergency Preparedness Network (EPnet); • IEC Response to Recent Events; Member State Prepaedness; • New Publications Translation; • New USIE Training Video; • The IEC in Numbers

  2. IEC Newsletter, No. 49, Third Quarter 2014

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-12-15

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. Table of contents: • Spolighting IEC Activities at the 58th IAEA General Conference; • TM on Lessons Learned from Past Emergency Preparedness Review (EPREV) Missions; • Third Full Response Exercise of 2014; • Israel joins RANET; • Launch of Emergency Preparedness Network (EPnet); • IEC Response to Recent Events; Member State Prepaedness; • New Publications Translation; • New USIE Training Video; • The IEC in Numbers.

  3. Evolution of IEC/TC 45 works and its sub-committees from 1960 to 1983

    International Nuclear Information System (INIS)

    Weill, J.

    1983-10-01

    The IEC, founded in 1906, is an independent international standards organization. Its standardization work deals with almost all branches of electrotechnology in the electrotechnical, electronical and data-processing field, covering all applications, as for example telecommunications and nuclear energy. The IEC Central Office is situated in Geneva (Switzerland). The Technical Committee No. 45 was set up in 1960 at the IEC general meeting in New Delhi, with the scope as given in the IEC Directory. Its revised scope is under consideration in the Committee of Action of the IEC and reads: ''To prepare international standards relating to electrical and electronic equipment and systems specific to nuclear applications''. The chart shows the organigram of the Technical Committee which comprises about 75 experts in the nuclear field from about 20 industrial countries. We can see here the standard diagram of a Technical Committee with its Sub-committees and Working Groups. The meetings are held in a member country at the request of its National Committee. One shows the places of the plenary meetings of TC 45 as well as the meetings of its Sub-committees and their Working Groups held till now. The Technical Committee 45 has in addition to its seven Working Groups also two Sub-committees having several further Working Groups of their own. The Sub-committee 45 A ''Reactor Instrumentation''. The Sub-committee 45 B ''Radiation protection instrumentation''. Till now TC 45 has published about 85 standards. Regarding work in preparation, one shows the present and future work within the Technical Committee and its Sub-committees. Impact of works and liaisons is briefly discussed [fr

  4. Certification of boiler safety equipment with ALSPA P320 system, to IEC 61508 standard; Certification des equipements de securite chaudiere avec le systeme ALSPA P320 selon la norme IEC 61508

    Energy Technology Data Exchange (ETDEWEB)

    Dalzon, J.P. [Alstom Power (France)

    2002-02-01

    Safety and environmental protection are major priorities governing Alstom work on control systems (Alspa P320) for power plant applications, especially when potentially dangerous processes like high-power flame boilers (typically rated at 100 to 600 MW) are involved. Here, automatic protection chains are implemented to guard against the risk of serious incident such as explosion and equipment destruction. In this kind of situation, the IEC 61508 standard provides baseline specifications for certification of safety systems. (authors)

  5. Commercial IEC portable neutron source

    International Nuclear Information System (INIS)

    Sved, J.

    1997-01-01

    The inertial electrostatic confinement (IEC) fusion grade plasma devices are being developed as a commercial industrial product by Daimler-Benz Aerospace (DASA), Center Trauen, which has an exclusive license from the University of Illinois (UI) to manufacture the commercial implementation of the Miley et al. IEC inventions. DASA is funding the UI Fusion Studies Laboratory basic IEC research and the intellectual property protection process. The association of the DASA Space Infrastructure division with an apparently unrelated technology has arisen from the perception that IEC technology may benefit from certain aerospace technologies and eventually create a market for space infrastructure services. In addition, DASA Center Trauen has a number of environmental technology businesses

  6. TU-G-213-03: IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

    Energy Technology Data Exchange (ETDEWEB)

    Culberson, W. [University of Wisconsin - Madison (United States)

    2015-06-15

    The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

  7. Effective IEC approaches for Asia. IEC evaluation workshop.

    Science.gov (United States)

    1996-02-01

    The UNFPA-supported project on development and distribution of information, education, and communication (IEC) materials in support of improving women's health and status was evaluated at a workshop held in Tokyo in December 13-15, 1995. The 1992-95 cycle of the project was analyzed by experts from Bangladesh, China, India, Indonesia, Malaysia, Nepal, the Philippines, and Vietnam plus three experts from the UNFPA/Country Support Team. The workshop also made it possible for the experts to identify needs as well as effective utilization of existing IEC materials. It was suggested that a nongovernmental organization be established for the distribution and effective use of these materials. The workshop mostly reviewed the print and audiovisual materials. Videos were also evaluated. The materials were found useful for the targeted region. Among other subregional issues it was noted that youth needs were inadequately addressed as they related to sexually transmitted diseases (STDs), unwanted pregnancy, risk of maternal mortality and morbidity, low birth weight, and premature birth. Although the women of the region comprise one-third of the world's population, 70% of the global annual maternal mortality of 500,000 occurs in the subregion. IEC materials should also target adolescents and their support groups. Other needs were also outlined: the expansion of educational opportunities for women, the promotion of employment, the involvement of men, and the training of personnel. The strategies used in the cycle helped strengthen self-reliance through information and experience sharing. The focus on women should be continued with more attention paid to adolescents and young adults, including males. Women's health issues should be expanded to include menopause, reproductive tract infections, STDs, HIV/AIDS prevention, and legal rights including abortion. The production of IEC materials should be identified through research and analysis of existing materials, focus group

  8. Overview, status and outline of the new IEC 61400-27. Electrical simulation models for wind power generation

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Poul [Wiley (John) and Sons, Inc., New York, NY (United States). Journal Dept.; Andresen, Bjoern [Siemens Wind Power (Denmark); Fortmann, Jens [RE-Power Systems AG (Germany); Johansen, Knud [Energinet.dk (Denmark); Pourbeik, Pouyan [EPRI (United States)

    2011-07-01

    This paper presents the ongoing work in Working Group (WG) 27 of IEC Technical Committee (TC) 88 developing a standard IEC 61400-27 for 'Electrical simulation models for wind power generation'. The purpose of the standardization work is to define generic simulation models for wind turbines and wind power plants, which are intended for power systems stability analyses. Thus, the models will be applicable for dynamic simulations of power system events such as faults, loss of generation or loads and switching of lines. The paper presents the actual status of the IEC TC88 WG27 work. Some of the challenges encountered during the process of the development of the standard are described, and expected outcome of the standard is also presented. (orig.)

  9. Can non-regulators audit Independent Ethic Committees (IEC), and if so, how?

    Science.gov (United States)

    Dent, N J; Sweatman, W J

    A number of guidelines and directives have reinforced the need for a more formalised approach to Independent Ethic Committees (IECs) and support the need to audit IECs. The key elements of an audit of an IEC are reviewed within the context of the European Guidelines for Auditing Independent Ethics Committees published by the European Forum for Good Clinical Practice (EFGCP). Auditing requirements in these recent guidelines and the EU Clinical Trial Directive are discussed as well as the methodology and type of documentation and SOPs that should be present at an audit. It is argued that both inspectorates and independent auditors need to conduct such audits to improve the overall global standard.

  10. Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

    International Nuclear Information System (INIS)

    Correa, Eduardo de Lima

    2010-01-01

    In this work it was developed and applied a quality control program of the X radiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtration, were established after the application of this quality control program following national and international recommendations. The reference ionization chamber has traceability to PTB and was regularly submitted to quality control tests for evaluation and analysis of its performance. The radiation qualities emerging from the X-radiation assembly (RQR-M), based on a phantom made up of an aluminum added filter (RQA-M), narrow beam condition (RQN-M) and broad beam condition (RQB-M), following the recommendations of the international standard IEC 61267 (2005) and the IAEA code of practice, TRS 457 (2007) were established. For the implantation of RQN-M and RQB-M radiation qualities, two mammography phantoms were developed. The half-value layers found are those presented by the German primary laboratory PTB, and varied from 0.35 to 1.21 mm Al. The air kerma rates were obtained for all the 15 implanted qualities. (author)

  11. IEC60193存在的部分问题及新国标对其的修正%Some Problems which Exist in IEC 60193 and the Amendment by the New National Standard

    Institute of Scientific and Technical Information of China (English)

    徐洪泉; 刘诗琪; 宫让勤; 梁妍

    2012-01-01

    本文在肯定IEC60193的同时,指出了其存在的部分问题,并结合新修订的国家标准对这些问题加以修正,从水轮机公称直径的定义、流道测量偏差要求的表述及空化系数定义等三个方面提出了比较符合中国实际的定义或表述.%This paper affirms the achievements of the IEC 60193, meanwhile, it points out some problems which exist in it, and considering the amendment by the New Chinese National Standard. It puts forward the definition or description which is in accord with actual situation of China from the three aspects of the definition for nominal diameter of the hydraulic turbines, the statement for requirement of the water passage flow measurement deviation and the definition of the cavitation sigma.

  12. Using the IEC standard to describe low-background detectors -- What can you expect?

    International Nuclear Information System (INIS)

    Keyser, R.M.; Wagner, S.

    1998-01-01

    Many measurements for environmental levels of the radioactive content require that the gamma-ray detector be low background, that is, free of any radioactive content. This is, of course, not possible, but the radioactivity in the detector must be reduced to as low a value as possible. The description or specification of the background spectrum necessary to achieve the desired results is needed. The new International Electrotechnical Commission (IEC) standard for describing the background makes the specification of the background in a high-purity germanium (HPGe) detector simple, unambiguous, and related to how the detector will be used. Users and manufacturers will finally be speaking the same language on this subject. Because this standard extends the specification of the performance of an HPGe detector, there is little history available for comparison and thus no means of determining a good value. To develop a history, the background spectrum for 500 low-background HPGe ORTEC detectors were all counted in similar low-background shields. These detectors were in a variety of mechanical cryostat and endcap configurations. The continuum background is a function of energy and detector size/configuration. The peak area for the peak energies listed in the standard is a function of detector size and configuration. The results thus give practical guidance for obtaining the most appropriate low-background detector for a specific measurement problem

  13. IEC Newsletter, No. 50, Fourth Quarter, 2014

    International Nuclear Information System (INIS)

    2014-12-01

    The IEC Newsletter is prepared by the Incident and Emergency Centre (IEC), Department of Nuclear Safety and Security of the IAEA. The Incident and Emergency Centre (… IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. The following topics are presented in this newsletter: Three Workshops at the Fukushima RANET Capacity Building Centre; Belgium joins RANET; IEC Response to Recent Events; Recent Exercises; Israel conducts National Response Exercise at Soreq; IACRNE: 24th Regular Meeting; Safety Requirements on Emergency Preparedness and Response; NIRS 2014 Workshop on Radiation Emergency Medicine; Member State Preparedness; New Publications and Translations and Forthcoming Events

  14. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rassow, J; Klieber, E

    1986-08-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example.

  15. Quality assurance procedures in radiotherapy - IEC specifications for equipment

    International Nuclear Information System (INIS)

    Rassow, J.; Klieber, E.

    1986-01-01

    The International Electrotechnical Commission (IEC) worked out international standards for requirements and tests of electrical, mechanical and radiation safety as well as for definition and tests of functional performance characteristics of radiotherapy equipments (medical electron accelerators, gamma beam teletherapy and afterloading equipments, simulators and accessories) and for clinical dosimeters and terminology for medical radiology. A survey is given on the actual state of standardization projects. The problems of such standards are shown for the standard for functional performance characteristics of medical electron accelerators as example. (orig.) [de

  16. IEC ready for turnaround in nuclear industry

    International Nuclear Information System (INIS)

    Schomberg, R.; Corte, E.; Thompson, I.

    2005-01-01

    The activity of IEC Technical Committee (TC) 45 (Nuclear Instrumentation) in conditions of turnaround in nuclear industry is considered. TC 45's main task is to lay down a comprehensive strategy for itself and its two subcommittees as well as to improve the relevance of the nuclear safety standards. Subcommittee 45A develops standards that apply to the electronic and electrical functions and associated systems and equipment used in the instrumentation and control systems of nuclear energy generation facilities. Subcommittee 45B develops and issues standards covering all aspects of instrumentation associated with radiation protection including radiation detectors, radiation monitoring, dosimetry and radiology [ru

  17. Consistent integrated automation. Optimized power plant control by means of IEC 61850; Durchgaengig automatisieren. Optimierte Kraftwerksleittechnik durch die Norm IEC 61850

    Energy Technology Data Exchange (ETDEWEB)

    Orth, J. [ABB AG, Mannheim (Germany). Geschaeftsbereich Power Generation

    2007-07-01

    Today's power plants are highly automated. All subsystems of large thermal power plants can be controlled from a central control room. The electrical systems are an important part. In future the new standard IEC 61850 will improve the integration of electrical systems into automation of power plants supporting the reduction of operation and maintenance cost. (orig.)

  18. Developing IEC prototypes for adolescents. IEC workshop.

    Science.gov (United States)

    1997-01-01

    Participants of the IEC Workshop for the Production of OHP Material on Reproductive Health for Adolescents and Young Adults held November 25-30 in Japan developed innovative, visually appealing overhead projector (OHP) transparencies to serve as prototype information, education, and communication (IEC) materials for the Asian Region. The materials cover a wide range of topics from early marriage to unwanted pregnancy. This paper briefly describes the prototypes. One group focused upon early marriage, an issue of considerable importance to the health and welfare of young women in countries such as Bhutan, India, and Nepal. Participants from China, Laos, Malaysia, and Thailand focused upon the issue of gender equality, while a third group developed OHP material to teach a range of issues related to young people's sexual and reproductive health. Finally, the fourth group, drawn from Indonesia, the Philippines, and Vietnam, focused upon the topic of menstruation with a prototype targeted to boys and girls aged 9-14 years. Boys were included to foster their understanding of menstruation as a natural phenomenon.

  19. Type tests performed on a personnel dosimetry system according to IEC 61066

    International Nuclear Information System (INIS)

    Castillo, Romel; Huamanlazo, Paula; Rojas, Enrique

    2015-01-01

    In this study, the verification of the Harshaw 6600 Plus TLD personal dosimetry system was made using the method of the IEC-61066 type tests and the recommendations of the ISO 4037 standards. For this purpose, five dosimeters were irradiated over a water phantom using an irradiator with a 137 Cs source; five dosimeters as control were also used. The evaluated parameters were homogeneity, detection limit, residual reading, linearity, reproducibility, droppings and temperature and humidity variations. The obtained results show that the Harshaw 6600 TLD dosimetric system fulfills the IEC 61066 criteria. (author)

  20. Determination of the detective quantum efficiency (DQE) of CMOS/CsI imaging detectors following the novel IEC 62220-1-1:2015 International Standard

    International Nuclear Information System (INIS)

    Michail, C.; Valais, I.; Martini, N.; Koukou, V.; Kalyvas, N.; Bakas, A.; Kandarakis, I.; Fountos, G.

    2016-01-01

    The purpose of the present study was to determine the Detective Quantum Efficiency (DQE) of CMOS imaging detectors, coupled to structured CsI:Tl and Gd_2O_2S:Tb scintillating screens, following the new IEC 62220-1-1:2015 International Standard. DQE was assessed after the experimental determination of the Modulation Transfer Function (MTF) and the Normalized Noise Power Spectrum (NNPS) in the general radiography energy range. Two CMOS sensors were used; one with a pixel size of 22.5 μmcoupled to a columnar CsI:Tl scintillator screen with thickness of 490 μm, which was placed in direct contact with the optical sensor and one with a pixel size of 74.8 μmcoupled to a 200 μmcolumnar CsI:Tl scintillator screen. The MTF was measured using the slanted-edge method (following both the IEC 62220-1:2003 and IEC 62220-1-1:2015 methods) while NNPS was determined by 2D Fourier transforming uniformly exposed images. Both parameters were assessed by irradiation under the RQA-3 and RQA-5 (IEC 62220-1-1:2015) beam qualities. The detector response functions were linear for the exposure ranges under investigation. MTFs calculated following the 62220-1:2003 protocol, were found in all cases overestimated in the higher frequency range (spatial frequencies higher than 2 cycles/mm). DQE values, determined with the IEC 62220-1:2003 method, were also found overestimated (spatial frequencies higher than 2 cycles/mm), due to the influence of both MTF and NNPS. The influence of both additive and multiplicative lag effects were found below 0.005, insuring that lag contributes less than 0.5% of the effective exposure. - Highlights: • DQE was measured with the novel 62220-1-1:2015 protocol and compared to 62220-1:2003. • Two CMOS sensors were evaluated. • DQE of the 62220-1:2003 was overestimated due to the addition of noise when averaging MTFs.

  1. IEC Newsletter, No. 48, Second Quarter 2014

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-09-15

    The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. Table of contents: • Competent Authorities Meeting; • ConvEx-1b Exercise in May 2014; • ConvEx-2a Exercise in April 2014; • IAEA Participates in First ConvEx-2e Exercise; • Second Full Response Mode Exercise of 2014; • New Interactive Learning Tool on INES; • INES Technical Meeting; • Participation in the RAD 2014 Conference; • Member State Preparedness; • Pilot Workshop for the Optimization of National Radiation Emergency Plans; • IEC Response to Recent Events; • China and Switzerland Join RANET; Japan Registers in New Functional Area; • Workshop on Radiation Monitoring; • New Publication Translation; • New USIE Feature: USIE Connect; • Twitter Milestone; • IEC News; • IEC Launches New Website.

  2. IEC Newsletter, No. 48, Second Quarter 2014

    International Nuclear Information System (INIS)

    2014-09-01

    The Incident and Emergency Centre (IEC) is the global focal point for emergency preparedness and response for nuclear and radiological safety or security related incidents, emergencies, threats or events of media interest. The IEC is also the world’s centre for coordination of international assistance in emergency. Table of contents: • Competent Authorities Meeting; • ConvEx-1b Exercise in May 2014; • ConvEx-2a Exercise in April 2014; • IAEA Participates in First ConvEx-2e Exercise; • Second Full Response Mode Exercise of 2014; • New Interactive Learning Tool on INES; • INES Technical Meeting; • Participation in the RAD 2014 Conference; • Member State Preparedness; • Pilot Workshop for the Optimization of National Radiation Emergency Plans; • IEC Response to Recent Events; • China and Switzerland Join RANET; Japan Registers in New Functional Area; • Workshop on Radiation Monitoring; • New Publication Translation; • New USIE Feature: USIE Connect; • Twitter Milestone; • IEC News; • IEC Launches New Website

  3. Implementing IEC 61850-7-420 DER Logical Nodes in a single board

    Directory of Open Access Journals (Sweden)

    Anderson Salazar-Zuluaga

    2017-09-01

    Full Text Available This article discusses the implementation of a variety of logical nodes (LNs of power generation systems based on distributed energy resources (DER in a single board computer (SBC. The SBC allows for the acquisition and encapsulation of analog signals from a photovoltaic (PV array with batteries, based on the IEC 61850-7-420 standard. To achieve this, an SBC integrated with an analog-digital conversion card (ADC enables to read the system’s analog values. The SBC communicates with the ADC card to encapsulate the collected data in the IEC 61850 data object by using the corresponding logical node (LN. An open license library was used to create the IEC 61850 server inside the SBC and the driver of the ADC card manufacturer to communicate both cards. This work aims to develop LNs for DERs in such way that manufacturers of power generation technologies based on renewable sources (such as the sun and/or the wind implement Intelligent Electronic Devices (IED and controllers in accordance with the scope of the standard for these logical nodes (LNs. Finally, the communication testing of the implementation and the results obtained are presented.

  4. Establishment Of Physicochemical Laboratory Of CANTI In Conformity With The Requirements Of ISO/IEC 17025:2005

    International Nuclear Information System (INIS)

    Pham Thi Hoang Ha; Phan Thi Luan; Le Thi Thanh Tam; Huynh Thai Kim Ngan; Duong Thi Bich Chi; Vo Thi Ngoc Cam; Ho Tran The Huu; Vo Thi Cuong; Tram Thi Khanh Quynh; Tran Tri Hai; To Ba Cuong

    2013-01-01

    23 testing methods have been established, compiled and issued in standard forms throughout the Project implementation. Besides, the Laboratory QA/QC system have been set up and put into operation from 01/09/2011. The Laboratory was assessed on 12-13/9/2012 by Bureau of Accreditation, Ministry of Science and Technology and has been certified to conform with the requirements of ISO/IEC 17025:2005 with the accreditation number VILAS 609 in pursuant to the Decision No. 365.2012/QD-VPCNCL dated on 20/12/2012. (author)

  5. ISO/IEC 17025 Sysmex R-500 hematology reticulocyte analyzer validation.

    Science.gov (United States)

    Dimopoulou, H A; Theodoridis, T; Galea, V; Christopoulou-Cokkinou, V; Spyridaki, M-H E; Georgakopoulos, C G

    2007-01-01

    The Sysmex R-500 (R-500) Hematology Analyzer is a bench-top system appropriate for the analysis of limited batches of blood samples. The R-500 provides percentage proportional (RET%), absolute reticulocyte (RET#), and absolute red blood cell (RBC#) counts. The system was validated at the Doping Control Laboratory of Athens, according to the International Committee for Standardization in Hematology, International Standards Organization (ISO/IEC) 17025, and World Antidoping Agency (WADA) specifications. The instrument calibration was performed according to the manufacturer and validation parameters comprised linearity, precision, uncertainty (intermediate and long-term precision), comparability, effect of drift, carryover, stability, and accuracy. The linearity and the comparability studies for RET#, RET%, and RBC# were expressed in regression factors (R2) and coefficients of correlation [r(x, y)], respectively. For the precision studies, the coefficients of variation for RET#, RET%, and RBC# were 9.49%, 9.83%, and ISO/IEC 17025 and WADA specifications.

  6. Auto-Mapping and Configuration Method of IEC 61850 Information Model Based on OPC UA

    Directory of Open Access Journals (Sweden)

    In-Jae Shin

    2016-11-01

    Full Text Available The open-platform communication (OPC unified architecture (UA (IEC62541 is introduced as a key technology for realizing a variety of smart grid (SG use cases enabling relevant automation and control tasks. The OPC UA can expand interoperability between power systems. The top-level SG management platform needs independent middleware to transparently manage the power information technology (IT systems, including the IEC 61850. To expand interoperability between the power system for a large number of stakeholders and various standards, this paper focuses on the IEC 61850 for the digital substation. In this paper, we propose the interconnection method to integrate communication with OPC UA and convert OPC UA AddressSpace using system configuration description language (SCL of IEC 61850. We implemented the mapping process for the verification of the interconnection method. The interconnection method in this paper can expand interoperability between power systems for OPC UA integration for various data structures in the smart grid.

  7. Inertial Electrostatic Confinement (IEC) devices

    International Nuclear Information System (INIS)

    Nebel, R.A.; Turner, L.; Tiouririne, T.N.; Barnes, D.C.; Nystrom, W.D.; Bussard, R.W.; Miley, G.H.; Javedani, J.; Yamamoto, Y.

    1994-01-01

    Inertial Electrostatic Confinement (IEC) is one of the earliest plasma confinement concepts, having first been suggested by P. T. Farnsworth in the 1950s. The concept involves a simple apparatus of concentric spherical electrostatic grids or a combination of grids and magnetic fields. An electrostatic structure is formed from the confluence of electron or ion beams. Gridded IEC systems have demonstrated neutron yields as high as 2 * 10 10 neutrons/sec. These systems have considerable potential as small, inexpensive, portable neutron sources for assaying applications. Neutron tomography is also a potential application. Atomic physics effects strongly influence the performance of all of these systems. Important atomic effects include elastic scattering, ionization, excitation, and charge exchange. This paper discusses how an IEC system is influenced by these effects and how to design around them. Theoretical modeling and experimental results are presented

  8. Rational Calibration of Four IEC 61400-1 Extreme External Conditions

    DEFF Research Database (Denmark)

    Larsen, Gunner Chr.; Hansen, Kurt Schaldemose

    2008-01-01

    Based on a set of asymptotic statistical models on closed form this paper presents a rational and consistent calibration of four extreme external conditions defined in the International Electrotechnical Commission (IEC) 61400-1 standard: extreme operating gust, extreme wind shear, extreme coheren...... and proposed specifications of the magnitudes of the extreme external wind conditions are highlighted and discussed using an illustrative example based on two selected terrain types. Copyright © 2008 John Wiley & Sons, Ltd....... gust with direction change and extreme wind direction change. These four extreme external conditions are used in the definition of six of the IEC 61400-1 ultimate load cases. The statistical models are based on simple and easily accessible mean wind speed and turbulence characteristics...

  9. Comparison of ANSI, IEC and CSA standards durability requirements on station-type metal oxide surge arresters for EHV power systems

    International Nuclear Information System (INIS)

    Hamel, A.; St-Jean, G.

    1992-01-01

    This paper presents an analysis of stresses applied to two actual types of station class surge arresters of the same voltage rating when tested for durability as prescribed by American (ANSI) International (IEC) and Canadian (CSA) standards for 315 kV and 734 kV power systems. The analysis which is made with an experimentally validated arrester model, reveals that the IEC duty cycle test is the most severe of all. In fact it can bring the varistors of an actual station-type arrester to a peak temperature of 129 degrees C, which leaves a margin of only 46 degrees C to its thermal stability limit at maximum continuous operating voltage (MCOV). Another actual arrester using lesser V-I-T varistor characteristics but larger varistor volume and better heat transfer from inside to outside the arrester, produces 103 degrees C which corresponds to a slightly better temperature margin of 49 degrees C. It is observed that even when using the lower performance V-I-T characteristics of the latter arrester, a thin-wall arrester housing design can improve heat transfer to a point where the margin improves to 101 degrees C on a hypothetical arrester

  10. Improving the quality control program for patient dose calibrator according to IEC 60580

    International Nuclear Information System (INIS)

    Costa, Nathalia Almeida; Potiens, Maria da Penha Albuquerque

    2013-01-01

    The objective of this work was to improve the program quality control of this equipment based on the International Standard IEC 60580 - Medical electrical equipment - Dose area product meters . The initial program was established following the recommendations of IEC 61674 quoting dosimeters with ionization chambers and / or semiconductor detectors used in diagnostic X-ray image, however, the IEC 60580 is referred specifically to gauges and KAP (kerma-area product) presents additional tests. Tests included: intrinsic relative error, repeatability, scanning resolution, settling time, restarting, float values, response time and spatial uniformity of response. As a rule, all measurements are within the range characteristic of equipment performance. Thus, the PDC (Patient Dose Calibrator) again shows a device with excellent functionality and reliability in characterization tests carried out to quality control as( for the test in clinical PKA meters

  11. IEC planning: eight state-of-the-art principles.

    Science.gov (United States)

    Middleton, J

    1983-12-01

    Considerable experience and research has been accumulated in the last 20 years on the ways in which information/education/communication (IEC) programs can be effectively designed, implemented, and evaluated. Possibly more effort has focused on population and family planning IEC than on any other sectoral program of development communication. Several principles have emerged which, taken together, define the state of the art in the field. These principles provide a framework of experience which can guide the development of comprehensive IEC programs. They include: policy and resource assessment; audience analysis; strategy design; message research and pretesting; participation and feedback; management; evaluation; and collaboration. The nature of the national policy base for population and family planning programs will determine the goals and approaches of the IEC program. Strong policies of limitation on popultion growth lead to equally strong and pervasive IEC efforts designed to directly affect contraceptive behavior. Assessment of existing policy is an essential aspect of the design of an effective IEC program. Policies establish the rationale and boundaries for action. Population and family planning programs are concerned with some of the most intimate human behavior. Consequently, structured and sensitive audience analysis has become an integral part of the design of IEC programs. The design of communication strategy requires clearly stated objectives. Principles of human learning are used to structure information appropriately. Message research and pretesting have become integral components of the strategy design process. Small scale research on specific objectives is necessary to establish the basis for message design. Audience participation and feedback in remaining phases of program development and implementation are important. The management of an IEC program requires a specific combination of planning, flexibility, and creativity. Evaluation of program

  12. The CMMI Product Suite and International Standards

    Science.gov (United States)

    2006-07-01

    standards: “2.3 Reference Documents 2.3.1 Applicable ISO /IEC documents, including ISO /IEC 12207 and ISO /IEC 15504.” “3.1 Development User Requirements...related international standards such as ISO 9001:2000, 12207 , 15288 © 2006 by Carnegie Mellon University Page 12 Key Supplements Needed...the Measurement Framework in ISO /IEC 15504; and • the Process Reference Model included in ISO /IEC 12207 . A possible approach has been developed for

  13. Architectural constraints in IEC 61508: Do they have the intended effect?

    International Nuclear Information System (INIS)

    Lundteigen, Mary Ann; Rausand, Marvin

    2009-01-01

    The standards IEC 61508 and IEC 61511 employ architectural constraints to avoid that quantitative assessments alone are used to determine the hardware layout of safety instrumented systems (SIS). This article discusses the role of the architectural constraints, and particularly the safe failure fraction (SFF) as a design parameter to determine the hardware fault tolerance (HFT) and the redundancy level for SIS. The discussion is based on examples from the offshore oil and gas industry, but should be relevant for all applications of SIS. The article concludes that architectural constraints may be required to compensate for systematic failures, but the architectural constraints should not be determined based on the SFF. The SFF is considered to be an unnecessary concept

  14. New way of demonstrating the competence of a laboratory measuring radionuclides - The international draft standard ISO/IEC DIS 17025

    International Nuclear Information System (INIS)

    Palsson, S.E.

    1999-01-01

    In recent years there has been increased interest, and even need, amongst laboratories performing measurements of radionuclides to obtain accreditation. It has been discussed how this could be achieved with maximum flexibility for the laboratories and with minimum effort. The issuing of a new draft international standard, the ISO/IEC DIS 17025, created speculations whether it could offer a new and better way for laboratories to obtain accreditation. It was decided within the NKS/BOK-1.1 project to explore possible options for obtaining accreditation and what possibilities the new standard could offer. The benefits of computerised document control systems were also explored. The results were reported at the 12th Annual Meeting of the Nordic Society for Radiation Protection, 23-27 August 1999. Since then the final version of the standard has been published. The voting will continue until November 16th 1999 and is not clear at present whether the standard will be accepted or not. The original version of this paper was updated to reflect these recent developments. (au)

  15. Developing IEC strategies for population programmes.

    Science.gov (United States)

    Cohen, S I

    1993-01-01

    The thrust of this article is to define terms of IEC, IEC strategies, the stepwise planning process for IEC, data requirements, the ideational change process, and the need for situational and institutional analysis. A chart provided an at-a-glance perspective on the 11 steps in IEC strategic planning for as many specific target groups as needed. The steps are to state the goals, select and prioritize the target audience, describe the target audience,, determine the IEC activities, outline appropriate messages, identify communication channels, identify managerial and organizational strategies, calculate the amount of resources required, identify a realistic time frame, and evaluate critical factors and obstacles. IEC goals are to contribute to solving a problem or supporting an issue, which involved attitudinal and/or behavioral changes. Many strategies are possible. The common weaknesses are the lack of priorities, the view of targets as a mass audience, a lack in support for population strategies, a lack of integration with family planning or specific population sectors, a lack of integration of up-to-data research findings on population programs, vague or difficult-to-measure objectives, reliance on printed media, and sporadic assessment of personnel needs. THe levels of strategy are identified as follows: 1) national and multisectoral, 2) national and sectoral specific, and 3) project specific. Traditional sociocultural research and KAP surveys are not sufficient to provide an understanding of the target audience. There must be an understanding of the stages of individual change: unaware, aware, concerned, information seeking, learning, motivated to change, initial behavior change, sustained behavior change, and adoption or refusal of behavior change. Beliefs must be distinguished from attitudes in measurement. Changes in beliefs may involve correction of misinformation; attitude change requires a motivational approach. Behavior may be determined by other

  16. Effectiveness of Information, Education and Communication (IEC) on ...

    African Journals Online (AJOL)

    IEC) on the public acceptability of unsafe abortion solution options of contraception, family life education including sex education and liberalization of abortion laws. Our aim was to use IEC to improve public acceptability of the recommended ...

  17. Control and management of distribution system with integrated DERs via IEC 61850 based communication

    Directory of Open Access Journals (Sweden)

    Ikbal Ali

    2017-06-01

    Full Text Available Distributed Energy Resources (DERs are being increasingly integrated in the distribution systems and resulting in complex power flow scenarios. In such cases, effective control, management and protection of distribution systems becomes highly challenging. Standardized and interoperable communication in distribution systems has the potential to deal with such challenges to achieve higher energy efficiency and reliability. Ed. 2 of IEC 61850 standards, for utility automation, standardizing the exchange of data among different substations, DERs, control centers, PMUs and PDCs. This paper demonstrates the modelling of information and services needed for control, management and protection of distribution systems with integrated DERs. This paper has used IP tunnels and/or mapping over IP layer for transferring IEC 61850 messages, such as sample values (SVs and GOOSE (Generic Object Oriented Substation Event, over distribution system Wide Area Network (WAN. Finally performance of the proposed communication configurations for different applications is analyzed by calculating End-to-End (ETE delay, throughput and jitter.

  18. Establishing the Isotope Hydrology Laboratory in accordance with ISO/IEC 17025:2005 standard

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh; Dinh Thi Bich Lieu; Vo Thi Tuong Hanh

    2013-01-01

    The ISO/IEC 17025:2005 General requirements for the competence calibration laboratories is basis for the accreditation body of the country in general and VILAS in particular recognizing the competence of laboratories. With the desire to prove that we have sufficient technical , management capacity , and the ability to provide the legally recognized and technically valuable test results, the Isotope Hydrology Laboratory have developed a quality management system in accordance with ISO / IEC 17025:2005, in which the laboratory quality manual has been developed. It describes the laboratory management system , scope of activities related to quality assurance of 13 major ions and tritium content measurement services in water samples. Under quality management system, there are management and technical procedures, analysis procedures, work instructions, technical documentation, file and form system. These documents define the roles, responsibilities, powers, detailed instructions for applying and maintaining effective quality management system. Isotope Hydrology Laboratory received a certificate of accreditation issued by Bureau of Accreditation which recognized the laboratory in accordance with ISO 17025:2005 with VILAS 670 accreditation code. Scope of recognition is analyzed 14 parameters: F - , Cl - , NO 2 - , NO 3 - , Br - , PO 4 3- , SO 4 2- , Li + , Na + , NH 4 + , K + , Mg 2+ , Ca 2+ and 3 H in water by ion chromatography and liquid scintillator counting method. (author)

  19. Inertial electrostatic confinement I(IEC) neutron sources

    International Nuclear Information System (INIS)

    Nebel, R.A.; Barnes, D.C.; Caramana, E.J.; Janssen, R.D.; Nystrom, W.D.; Tiouririne, T.N.; Trent, B.C.; Miley, G.H.; Javedani, J.

    1995-01-01

    Inertial Electrostatic Confinement (IEC) is one of the earliest plasma confinement concepts, having first been suggested by P.T. Farnsworth in the 1950s. The concept involves a simple apparatus of concentric spherical electrostatic grids or a combination of grids and magnetic fields. An electrostatic structure is formed from the confluence of electron or ion beams. Gridded IEC systems have demonstrated neutron yields as high as 2*10 [10]. neutrons/sec in steady state. These systems have considerable potential as small, inexpensive, portable neutron sources for assaying applications. Neutron tomography is also a potential application. This paper discusses the IEC concept and how it can be adapted to a steady-state assaying source and an intense pulsed neutron source. Theoretical modeling and experimental results are presented

  20. Standards update -- 1995

    Energy Technology Data Exchange (ETDEWEB)

    Mason, J.D.

    1995-12-31

    What a year this has been! Not since 1986, when SGML was being finished, has there been so much activity in the SGML world. In ISO, there are new standards being completed and old ones (some of which are not really all that old) being revised. As you`ll be hearing, there is lots of SGML activity in the applications world--particularly on the Internet--and that`s causing other kinds of standards activity. WG8 divides its work into five ``Rapporteur Groups`` (or ``RGs``) for DSSSL, Font Description and Interchange, SGML, SPDL, and Hypermedia Languages. Since interest is in DSSSL, SGML, and Hypermedia Languages, the author only mentions that the other groups have been active, too. The Fronts group has been doing amendments to its standards, ISO/IEC 9541 and ISO/IEC 10036. The Fronts groups has been active in providing support for ISO/IEC 10646, the massive character coding standard that has drawn a lot of attention in the SGML world. The SPDL group has at long last finished its standard, the Standard Page Description Language (ISO/IEC 10180) and is about to publish it. More detailed discussions are given for activity in SGML, DSSSL, and Hypermedia Languages.

  1. Basic Characteristics of IEC Flickermeter Processing

    Directory of Open Access Journals (Sweden)

    Jarosław Majchrzak

    2012-01-01

    . This paper presents the results of the numerical simulations that reconstruct the processing of flickermeter in frequency domain. With the use of standard test signals, the characteristics of flickermeter were determined for the case of amplitude modulation of input signal, frequency modulation of input signal, and for input signal with interharmonic component. For the needs of simulative research, elements of standard IEC flickermeter signal chain as well as test signal source and tools for acquisition, archiving, and presentation of the obtained results were modeled. The results were presented with a set of charts, and the specific fragments of the charts were pointed out and commented on. Some examples of the influence of input signal’s bandwidth limitation on the flickermeter measurement result were presented for the case of AM and FM modulation. In addition, the diagrams that enable the evaluation of flickermeter’s linearity were also presented.

  2. Validation of Generic Models for Variable Speed Operation Wind Turbines Following the Recent Guidelines Issued by IEC 61400-27

    Directory of Open Access Journals (Sweden)

    Andrés Honrubia-Escribano

    2016-12-01

    Full Text Available Considerable efforts are currently being made by several international working groups focused on the development of generic, also known as simplified or standard, wind turbine models for power system stability studies. In this sense, the first edition of International Electrotechnical Commission (IEC 61400-27-1, which defines generic dynamic simulation models for wind turbines, was published in February 2015. Nevertheless, the correlations of the IEC generic models with respect to specific wind turbine manufacturer models are required by the wind power industry to validate the accuracy and corresponding usability of these standard models. The present work conducts the validation of the two topologies of variable speed wind turbines that present not only the largest market share, but also the most technological advances. Specifically, the doubly-fed induction machine and the full-scale converter (FSC topology are modeled based on the IEC 61400-27-1 guidelines. The models are simulated for a wide range of voltage dips with different characteristics and wind turbine operating conditions. The simulated response of the IEC generic model is compared to the corresponding simplified model of a wind turbine manufacturer, showing a good correlation in most cases. Validation error sources are analyzed in detail, as well. In addition, this paper reviews in detail the previous work done in this field. Results suggest that wind turbine manufacturers are able to adjust the IEC generic models to represent the behavior of their specific wind turbines for power system stability analysis.

  3. Critical issues for implementation of the standard NBR ISO/IEC 17025:2005 in Testing and Calibration Laboratory: case study at a public institution

    International Nuclear Information System (INIS)

    Castro, Denise Confar Carvalho de

    2013-01-01

    The public institution aims to promote excellence in public management to contribute to the quality of services provided to its customers and to increase competitiveness in the country, as well as its international projection. A technical barrier to trade that can lead to dissatisfaction and achieve the reputation of the institution is failing the test or calibration results and measurement data, thereby accreditation is regarded as the first essential step to facilitate the mutual acceptance of test results and calibration or measurement data. For recognition, laboratories need to demonstrate full compliance with both the sections of ISO/IEC 17025:2005, i.e. management and technical requirements. This research aims to discuss the critical aspects for implementation of ABNT NBR ISO / IEC 17025:2005 for calibration and testing of a Public Institution seeking accreditation of its laboratories with INMETRO, national accreditation body Laboratories. Besides getting preventive, corrective and improvement actions continues guidelines. Furthermore, the methodology used was to conduct a literature search and apply a questionnaire to identify the degree of agreement / disagreement of the foundations of the standard servers. Analysis of the results showed that the critical issues were: commitment, training, resources (infrastructure, human) and culture. (author)

  4. Inertial electrostatic confinement (IEC) fusion fundamentals and applications

    CERN Document Server

    Miley, George H

    2014-01-01

    This book provides readers with an introductory understanding of Inertial Electrostatic Confinement (IEC), a type of fusion meant to retain plasma using an electrostatic field. IEC provides a unique approach for plasma confinement, as it offers a number of spin-off applications, such as a small neutron source for Neutron Activity Analysis (NAA), that all work towards creating fusion power. The IEC has been identified in recent times as an ideal fusion power unit because of its ability to burn aneutronic fuels like p-B11 as a result of its non-Maxwellian plasma dominated by beam-like ions. This type of fusion also takes place in a simple mechanical structure small in size, which also contributes to its viability as a source of power. This book posits that the ability to study the physics of IEC in very small volume plasmas makes it possible to rapidly investigate a design to create a power-producing device on a much larger scale. Along with this hypothesis the book also includes a conceptual experiment propose...

  5. Strategies for Refining IEC 61400-2: Wind Turbine Generator Systems - Part 2: Safety of Small Wind Turbines: Preprint

    International Nuclear Information System (INIS)

    van Dam, J. J. D.; Forsyth, T. L.; Hansen, A. C.

    2001-01-01

    This paper provides a status of the changes currently being made by IEC Maintenance Team 02 (MT02) to the existing IEC 61400-2 ''Safety of small wind turbines.'' In relation to the work done by IEC MT02, work has been done by NREL and Windward Engineering under the DOE/NREL Small Wind Turbine (SWT) Project. Aeroelastic models were built and measurements taken on a Whisper H40 turbine and an AOC 15/50. Results from this study were used to verify the simple design equations. This verification will be used to evaluate how changes made in the design load estimation section of the standard work out for a broad range of turbine configurations. The work presented here builds on work performed by Van Hulle (1996)

  6. New quantitative safety standards: different techniques, different results?

    International Nuclear Information System (INIS)

    Rouvroye, J.L.; Brombacher, A.C.

    1999-01-01

    Safety Instrumented Systems (SIS) are used in the process industry to perform safety functions. Many factors can influence the safety of a SIS like system layout, diagnostics, testing and repair. In standards like the German DIN no quantitative analysis is demanded (DIN V 19250 Grundlegende Sicherheitsbetrachtungen fuer MSR-Schutzeinrichtungen, Berlin, 1994; DIN/VDE 0801 Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, Berlin, 1990). The analysis according to these standards is based on expert opinion and qualitative analysis techniques. New standards like the IEC 61508 (IEC 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems, IEC, Geneve, 1997) and the ISA-S84.01 (ISA-S84.01.1996 Application of Safety Instrumented Systems for the Process Industries, Instrument Society of America, Research Triangle Park, 1996) require quantitative risk analysis but do not prescribe how to perform the analysis. Earlier publications of the authors (Rouvroye et al., Uncertainty in safety, new techniques for the assessment and optimisation of safety in process industry, D W. Pyatt (ed), SERA-Vol. 4, Safety engineering and risk analysis, ASME, New York 1995; Rouvroye et al., A comparison study of qualitative and quantitative analysis techniques for the assessment of safety in industry, P.C. Cacciabue, I.A. Papazoglou (eds), Proceedings PSAM III conference, Crete, Greece, June 1996) have shown that different analysis techniques cover different aspects of system behaviour. This paper shows by means of a case study, that different (quantitative) analysis techniques may lead to different results. The consequence is that the application of the standards to practical systems will not always lead to unambiguous results. The authors therefore propose a technique to overcome this major disadvantage

  7. Perancangan SMKI Berdasarkan SNI ISO/IEC27001:2013 dan SNI ISO/IEC27005:2013 (Studi Kasus DPTSI-ITS

    Directory of Open Access Journals (Sweden)

    Furqon Mauladani

    2018-03-01

    Full Text Available Institut Teknologi Sepuluh Nopember (ITS adalah salah satu universitas di Surabaya. ITS telah menggunakan TIK untuk keperluan operasional bisnisnya (contohnya isi kartu program studi, proses absensi, pembaharuan informasi, dan lainnya. Penggunaan TIK tidak dapat dipisahkan dari ancaman yang dapat mengganggu operasional TIK. Ancaman terdiri dari ancaman yang berasal dari luar (penyebaran malware, aktifitas social engineering, orang dalam (sengaja, tidak sengaja, kegagalan teknis (kesalahan penggunaan, kegagalan perangkat keras/lunak ataupun bencana alam (kebakaran, gempa, banjir. Metode yang digunakan pada penelitian ini adalah melakukan manajemen resiko keamanan informasi berdasarkan SNI ISO/IEC 27005 dan perancangan dokumen SMKI berdasarkan SNI ISO/IEC 27001. Hasil penelitian ini adalah 60 resiko yang tidak diterima dari total 228 resiko yang telah teridentifikasi. Dari 60 resiko tersebut, terdapat 58 risk modification, 1 risk avoidance, dan 1 risk sharing. Tata kelola keamanan informasi yang dirancang berdasarkan SNI ISO/IEC 27001 adalah ruang lingkup SMKI, kebijakan SMKI, proses penilaian resiko, proses penanganan resiko, statement of applicability, dan sasaran keamanan informasi.

  8. US-Japan IEC Workshop on Small Plasma and Accelerator Neutron Sources. Final report

    International Nuclear Information System (INIS)

    Miley, George H.

    2008-01-01

    The history of IEC development will be briefly described, and some speculation about future directions will be offered. The origin of IEC is due to the brilliance of Phil Farnsworth, inventor of electronic TV in the US. Early experiments were pioneered in the late 1960s by Robert Hirsch who later became head of the DOE fusion program. At that time studies of IEC physics quickly followed at the University of Illinois and at Penn State University. However, despite many successes in this early work, IEC research died as DOE funding stopped in the mid 1980s. In the early 90's, R. W. Bussard of EMC revived work with a new major project based on a magnetic assisted IEC. While doing supportive studies for that project, G. Miley proposed a grided 'STAR mode' IEC as a neutron source for NAA. This concept was later used commercially by Daimler-Benz in Germany to analysis impurities in incoming ores. This represented a first practical application of the IEC. During this period other research groups at LANL, U of Wisconsin and Kyoto University entered IEC research with innovative new concepts and approaches to IEC physics and applications. Much of this work is documented in the present and in past US-Japan Workshops. At present we stand on the threshold of a new area of IEC applications as neutron source, for isotope production, and as a plasma source. These applications provide a way to continue IEC understanding and technology development with the ultimate goal being a fusion power plant. Indeed, a distinguishing feature of the IEC vs. other fusion confinement approaches is the unique opportunity for 'spin off' applications along the way to a power producing plant.

  9. Characterization of radiation qualities used for the determination of characteristic in CT application according to IEC 61267:2005

    International Nuclear Information System (INIS)

    Dias, Daniel M.; Silva Junior, Iremar A. da; Potiens, Maria da Penha A.

    2009-01-01

    The purpose of this study was to establish the standard RQT radiation qualities which represent simulations of the unattenuated beam used in Computed Tomography (CT). Thus, to avoiding excessive efforts for establishing a radiation quality by means of the spectral distribution of the photon fluence, the characterization of these standard radiation qualities was expressed in terms of the X-ray tube voltage, first and second half-value layer (HVL). To establishing the standard radiation beam, according to the IEC 61267 and the TRS 457 was measured first of all the correct values of the X ray tube voltages in terms of Practical Peak Voltage. The standard radiation qualities RQT were produced using the same set up mounted for the RQR qualities which had been early established, and for simulating the patient in order to achieve the standard RQT series, suitable thicknesses of layers of copper were used to obtain the values of the first HVL according to IEC 61267. (author)

  10. The first IEC fusion industrial neutron generator and developments

    Science.gov (United States)

    Sved, John

    1999-06-01

    Inertial Electrostatic Confinement fusion grade plasma containment has been sporadically researched since the early 1960's. In the 1990's the work of G. H. Miley and his team at the University of Illinios, Fusion Studies Laboratory, Champaign-Urbana has stimulated a collaboration with industry. The development and test program for the first industrial IEC neutron generator has progressed to the point where an endurance test is under way to demonstrate at least 10,000 hours of operational life of the sealed chamber device without servicing. The market entry goals of steady 107 D-D n/s CW output with an air-cooled system have been achieved. DASA has invested in the development of the industrial product and the continuing basic research at the UI-FSL. The complete DASA FusionStar IEC-PS1 point source neutron generator set is described with emphasis on the interfaces to user NAA systems. The next product developments are pulsed neutron operations and higher fusion reaction rates of up to 1010 by means of affordable add-ons to the basic IEC-PS system. The production engineering experience gained will next be applied to a more challenging line source variant of the IEC. Beyond neutron and proton sources, several other IEC applications are being developed.

  11. Establishment of radiation qualities for radiodiagnostics in LCR/UERJ according to IEC 61267 and TRS 457

    International Nuclear Information System (INIS)

    Silva, D.B. da; Magalhaes, L.A.G.; Estrada, J.J.S.; Pires, E.J.; David, M.G.; Ferreira, N.M.P.D.

    2015-01-01

    The main goal of this work is to establish the radiation qualities of the Laboratório de Ciências Radiológicas (LCR) conventional X-ray equipment for calibrations in radiodiagnostics according to the recommendations of IEC 61267 and TRS 457. Tests were conducted to evaluate the homogeneity of the radiation field, high voltage applied to the X-ray tube, scattering, half-value layers (HVL) and homogeneity coefficients. The results obtained that characterize the radiation field, satisfy the conditions required by TRS 457. Invasive high voltage measures presented results compatible with the requirements of this standard. The HVL measures showed that for the first HVL the tolerance limits of IEC 61267, and the values for the homogeneity coefficients were within the limits established. The quality tests performed in this work were highly satisfactory in meeting the standard requirements. Thus, the main goal was achieved, and the methodology can be used by other similar X-ray systems. - Highlights: • Establishment the radiation qualities for X-ray calibrations in radiodiagnostics. • Comparison to kV between invasive and noninvasive method. • Determination of additional filtrations suggested by IEC 61267. • Determination of the radiation scattered by the experimental setup as TRS 457. • Determination of HVLs as TRS 457.

  12. Calibration Laboratory for Medical Physics towards ISO/ IEC 17025 accreditation: Experience and challenges

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Abdul Aziz Ramli; Muhammad Jamal Isa; Sharul Azlan Azizan

    2011-01-01

    Medical Physics Calibration Laboratory is laboratory where placed under Medical Physics Group, Radiation Healthy and Safety Division. This laboratory offers calibration services to their customers that covered doses calibration, tube voltan (kVp), exposure doses, sensitometer and densitometer. After 12 years of operation, it is the right time for this laboratory to upgrade their quality services based on ISO/ IEC 17025. Accreditation scope covered calibration for diagnostic doses only. Starting from 2009, serious effort was done to prepare the quality documents that covered quality manual, quality procedure and work orders. Meanwhile, several series of audit were done by Quality Management Center (QMC), now Innovation Management Center (IMC) with collaboration with Standard Department. This paper works revealed challenges and experience during the process toward ISO/ IEC 17025 accreditation. (author)

  13. IEC 61850 based refurbishment strategies for protection and automation systems

    Energy Technology Data Exchange (ETDEWEB)

    Tholomier, D. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada); Hossenlopp, L. [Areva T and D Automation Inc., Paris (France); Apostolov, A. [Omicron Electronics, Houston, TX (United States)

    2008-07-01

    Electric utilities are currently facing the challenge of refurbishing aging transmission networks and power system infrastructure at a time of severe economic, environmental and competitive constraints. This paper addressed the issue of an appropriate approach to retrofit the hardware and software of substation secondary systems, and how IEC standards could be used to set up a long term strategy. The first part of the paper considered an asset management strategy for refurbishing substation secondary systems, while the second part of the paper addressed the strategies for refurbishing existing power plants. The final section of the paper analyzed refurbishment strategies designed to protect power distribution systems. The impact of IEC 61850 and how legacy devices can be integrated in substation automation systems were discussed. It was concluded that new SCADA systems are needed to handle new technology. Additional features like remote control, remote settings, remote disturbance records analysis and remote maintenance are also needed to properly operate the power system. The value of preventive maintenance using remote monitoring systems to determine the status of all the digital electronic devices installed in substation was also discussed. IEC 61850 offers several opportunities to improve grid operation and control. It supports interoperability between protective relays and control devices from different manufacturers in the substation, which is required in order to achieve substation level interlocking, protection and control functions and improve the efficiency of microprocessor based relays applications. This technology has now passed the initial stage of implementation and several projects are underway worldwide. 13 figs.

  14. Migración de un SGSI basado en ISO/IEC 27001:2005 a la versión ISO/IEC 27001:2013

    OpenAIRE

    Espol; Rendón Freire, María José

    2015-01-01

    Este proyecto tiene como objetivo identificar los cambios en los requisitos de la norma ISO/IEC 27001:2013 respecto a la versión 2005, para lograr la actualización de un sistema de gestión de seguridad de la información basado en ISO/IEC 27001:2005 acorde a lo establecido en el nuevo estándar. Guayaquil Magíster en Seguridad Informática Aplicada

  15. Atomic processes in Inertial Electrostatic Confinement (IEC) devices

    International Nuclear Information System (INIS)

    Nebel, R.A.; Turner, L.; Tiouririne, T.N.; Barnes, D.C.; Nystrom, W.D.; Bussard, R.W.; Miley, G.H.; Javedani, J.; Yamamoto, Y.

    1993-01-01

    Inertial Electrostatic Confinement (IEC) is one of the earliest plasma confinement concepts, having first been suggested by P. T. Farnsworth in the 1950s. The concept involves a simple apparatus of concentric spherical electrostatic grids or a combination of grids and magnetic fields. An electrostatic structure is formed from the confluence of electron or ion beams. Gridded IEC systems have demonstrated neutron yields as high as 2*10 10 neutrons/sec. These systems have considerable potential as small, inexpensive, portable neutron sources for assaying applications. Neutron tomography is also a potential application. Atomic physics effects strongly influence the performance of all of these systems. Important atomic effects include elastic scattering, ionization, excitation, and charge exchange. This paper discusses how an IEC system is influenced by these effects and how to design around them. Theoretical modeling and experimental results are presented

  16. A fully automated system for ultrasonic power measurement and simulation accordingly to IEC 61161:2006

    NARCIS (Netherlands)

    Costa-Felix, R.P.B.; Alvarenga, A.V.; Hekkenberg, R.

    2011-01-01

    The ultrasonic power measurement, worldwide accepted, standard is the IEC 61161, presently in its 2nd edition (2006), but under review. To fulfil its requirements, considering that a radiation force balance is to be used as ultrasonic power detector, a large amount of raw data (mass measurement)

  17. Concept for a high performance MHD airbreathing-IEC fusion rocket

    International Nuclear Information System (INIS)

    Froning, H.D. Jr.; Miley, G.H.; Nadler, J.; Shaban, Y.; Momota, H.; Burton, E.

    2001-01-01

    Previous studies have shown that Single-State-to-Orbit (SSTO) vehicle propellant can be reduced by Magnets-Hydro-Dynamic (MHD) processes that minimize airbreathing propulsion losses and propellant consumption during atmospheric flight, and additional reduction in SSTO propellant is enabled by Inertial Electrostatic Confinement (IEC) fusion, whose more energetic reactions reduce rocket propellant needs. MHD airbreathing propulsion during an SSTO vehicle's initial atmospheric flight phase and IEC fusion propulsion during its final exo-atmospheric flight phase is therefore being explored. Accomplished work is not yet sufficient for claiming such a vehicle's feasibility. But takeoff and propellant mass for an MHD airbreathing and IEC fusion vehicle could be as much as 25 and 40 percent less than one with ordinary airbreathing and IEC fusion; and as much as 50 and 70 percent less than SSTO takeoff and propellant mass with MHD airbreathing and chemical rocket propulsion

  18. Concept for a high performance MHD airbreathing-IEC fusion rocket

    Science.gov (United States)

    Froning, H. D.; Miley, G. H.; Nadler, J.; Shaban, Y.; Momota, H.; Burton, E.

    2001-02-01

    Previous studies have shown that Single-State-to-Orbit (SSTO) vehicle propellant can be reduced by Magnets-Hydro-Dynamic (MHD) processes that minimize airbreathing propulsion losses and propellant consumption during atmospheric flight, and additional reduction in SSTO propellant is enabled by Inertial Electrostatic Confinement (IEC) fusion, whose more energetic reactions reduce rocket propellant needs. MHD airbreathing propulsion during an SSTO vehicle's initial atmospheric flight phase and IEC fusion propulsion during its final exo-atmospheric flight phase is therefore being explored. Accomplished work is not yet sufficient for claiming such a vehicle's feasibility. But takeoff and propellant mass for an MHD airbreathing and IEC fusion vehicle could be as much as 25 and 40 percent less than one with ordinary airbreathing and IEC fusion; and as much as 50 and 70 percent less than SSTO takeoff and propellant mass with MHD airbreathing and chemical rocket propulsion. .

  19. The challenge of Ciemat internal dosimetry service for accreditation according to ISO/IEC 17025 standard, for in vivo and in vitro monitoring and dose assessment of internal exposures

    International Nuclear Information System (INIS)

    Lopez, M.A.; Martin, R.; Hernandez, C.; Navarro, J.F.; Navarro, T.; Perez, B.; Sierra, I.

    2016-01-01

    monitoring of workers for internal radiation exposure' and ISO 20553(4) 'Monitoring of workers occupationally exposed to a risk of internal contamination with radioactive material'. Appropriate and validated commercial software implementing current ICRP biokinetic and dosimetric models was approved as tool for dose assessment. CIEMAT IDS was accredited according to ISO/IEC 17025 in 2012 as demonstration of technical competence for monitoring and dose assessment due to internal exposures, considering the methods described as follows: In vivo monitoring of (a) gamma emitters in the total body using a FASTSCAN counter or one NaI(Tl) detector inside a shielded room, (b) actinides in the lungs with four LE Ge detectors and (c) radioiodine ( 125 I, 131 I) in the thyroid with detection systems mentioned before. In vitro monitoring of (a) alpha emitters in urine and faeces by alpha spectrometry, (b) beta emitters ( 90 Sr, 3 H, 32 P, 14 C, 35 S) in urine by liquid scintillation counting (LSC) and (c) uranium in urine using kinetic phosphorescence analyser (KPA). ICP-SFMS technique is in process of approval and accreditation for the measurement of uranium, thorium and plutonium in urine. Evaluation of committed effective dose E(50) from monitoring data, applying ISO standards, ICRP publications and IDEAS guidelines (GL) (EURADOS Report 2013-01)(5). (authors)

  20. [Approval of ISO/IEC 17025 and quality control of laboratory testing].

    Science.gov (United States)

    Yamamoto, Shigeki; Asakura, Hiroshi; Machii, Kenji; Igimi, Shizunobu

    2010-01-01

    First section of Division of Biomedical Food Research, National Institute of Health Sciences (NIHS) was approved by ISO/IEC 17025 as a laboratory having an appropriate laboratory testing technique. NIHS is the first national laboratory approved by ISO/IEC 17025. NIHS has also been accepted the appropriate technique and facility for the BSL3 level pathogens by ISO/IEC 17025. NIHS is necessary to take an external audit almost every year. This approval is renewed every 4 years.

  1. Gloss uniformity measurement update for ISO/IEC 19751

    Science.gov (United States)

    Ng, Yee S.; Cui, Chengwu; Kuo, Chunghui; Maggard, Eric; Mashtare, Dale; Morris, Peter

    2005-01-01

    To address the standardization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standardization committee for office equipment chartered the W1.1 project with the responsibility of drafting a proposal for an international standard for the evaluation of printed image quality1. An ISO draft Standard2, ISO/WD 19751-1, Office Equipment - Appearance-based image quality standards for printers - Part 1: Overview, Procedure and Common Methods, 2004 describes the overview of this multi-part appearance-based image quality standard. One of the ISO 19751 multi-part Standard"s tasks is to address the appearance-based gloss and gloss uniformity issues (in ISO 19751-2). This paper summarizes the current status and technical progress since the last two updates3, 4. In particular, we will be discussion our attempt to include 75 degree gloss (G75) objective measurement5 in differential gloss and within-page gloss uniformity. The result for a round-robin experiment involving objective measurement of differential gloss using G60 and G75 gloss measurement geometry is described. The results for two perceptual-based round-robin experiments relating to haze effect on the perception of gloss, and gloss artifacts (gloss streaks/bands, gloss graininess/mottle) are discussed.

  2. IEC Information Bulletin, No. 39, First Quarter 2012

    International Nuclear Information System (INIS)

    2012-01-01

    On 28 March, the Incident and Emergency Centre (IEC) conducted its first Full Response Exercise of 2012. Over 30 staff members from the Department of Nuclear Safety and Security and the Division of Public Information participated. The IEC was activated into full response mode at approximately 9 a.m. This full response lasted most of the day and led up to a 'lessons learned' discussion at the end of the day. Florian Baciu, the IEC Response System Coordinator, noted: ''Although many of the participants were involved in the IAEA response to the accident at TEPCO's Fukushima Daiichi nuclear power plant, this exercise gave them the opportunity to practice procedures which they had not used since then. In addition, we had several staff members relatively new to the IAEA's Incident and Emergency System among the participants.'' Hilaire Mansoux, one of the Emergency Response Managers for the exercise, stated: ''The scenario was quite complex, requiring a good flow of information.'' The IEC staff had developed a scenario in which a meltdown and resulting release of radioactive materials to the environment from a nuclear power plant in a Member State was caused by a criminal act. All outside organizations were represented by the IEC staff in a simulation cell, which periodically contributed information using telephone calls, faxes, emails and messages through the IAEA's Unified System for Information Exchange in Incidents and Emergencies (USIE). The tasks of the IAEA in the area of emergency response were expanded through the mandate given by Member States following the events at Fukushima Daiichi last year. In the area of communication and information dissemination, the IAEA was also given, among other tasks, the mandate to assess emergency situations by providing 'analysis of available information and prognosis of possible scenarios'. Together with other matters, the assessment aspect was addressed in this full response exercise.

  3. Establishment of qualities mammography according to the standard IEC-61267 in the laboratory of metrology of ionizing radiation of the National Center of Dosimetry and enlargement of the accreditation by ENAC

    International Nuclear Information System (INIS)

    Roig Petit, F.; Mestre de Juan, V.; Alabau Albors, J.; Palma Copete, J.; Ruiz Rodriguez, J. C.; Pons Mocholi, S.

    2013-01-01

    The extension of the accreditation of the laboratory of the National Center Dosimetry (No. 58/LC10.036) by the national accreditation entity (ENAC), according to the ISO 17025 standard [2], for the standard qualities of mammography by the IEC 61267 comes to meet part of the needs that demand our health care environment in terms of radiation measuring instruments calibration. This work intends to publicize this enlargement commenting on the different phases of the process to get the accreditation. (Author)

  4. A quality assurance system for personal monitoring in Ireland: experience to date and transition from EN 45001 to ISO/IEC 17025

    International Nuclear Information System (INIS)

    Currivan, L.; Spain, D.; Rafferty, B.

    2002-01-01

    Up to 2000 the RPII was the competent authority for approval of dosimetry services operating within Ireland. However the transposition into Irish Law of Council Directive 96/29 Euratom in May 2000 means that dosimetry services operating in Ireland must now attain accreditation to the standard of EN-45001 or its equivalent. To comply with this new legislation the RPII sought accreditation for the Dosimetry Service from the Irish National Accreditation Board (NAB). In accordance with the EN-45000 series of European Standards and the relevant ISO guides NAB tests accuracy of results and accredits organisations as appropriate. In September 2000 accreditation was granted to the Dosimetry Service for individual monitoring of personnel who are occupationally exposed to ionising radiation. The scope of the accreditation covers the evaluation of personal doses, for photon and beta, using TLD. Frequent internal quality audits, together with periodic inter-laboratory test programmes, ensure that these quality standards are maintained. This accreditation fulfils the approval under legislation for dosimetry services. The new standard, ISO/IEC 17025, was introduced by ISO (the International Organization for Standardization) and IEC (the International Electrotechnical Commission) in 1999. This standard was introduced in Ireland by NAB and will be implemented for future assessments. The aim of this paper is to describe the quality system currently operated by the RPII's Dosimetry Service, our practical experience to date, and to outline the transition from EN-45001 to ISO/IEC 17025

  5. Compatibility of IEC 61400-27-1 Ed 1 and WECC 2nd Generation Wind Turbine Models

    DEFF Research Database (Denmark)

    Göksu, Ömer; Sørensen, Poul Ejnar; Morales, Ana

    2016-01-01

    , respectively. Although the two working groups have been collaborating closely, there are small differences between the approaches of the two modelling standards, especially in terms of parameter sets and complexities for different functions. In this paper, compatibility of the IEC and WECC wind turbine models...

  6. Present problems of standardization in nuclear instrumentation in Romania

    International Nuclear Information System (INIS)

    Purghel, Lidia

    2001-01-01

    The continuos development of nuclear techniques, based on international cooperation, led to the need for producing national and international standards referring to terminology, classification, technical characteristic, testing and calibration methods for nuclear instrumentation. The international standardization activity is organised in the frame of the well-known organization like IEC, ISO, ICRU, ICRP, IOLM, CENELEC, EFOMP, WHO. High advances were obtained in the standardization of the ionising radiation dosimetry in the frame of the International Commission for Radiation Units (ICRU) which started its works 1925. Romania is member of the International Electrotechnical Commission (IEC) from 1920 when its president was the formal member of Romanian Academy, professor Remus Radulet. Romania is effectively involved in standardization activities in the field nuclear instrumentation both as user and manufacturer of nuclear instrumentation. At national level the Technical Committee 45, as a branch of the Romanian Electrotechnical Committee is hosted by Horia Hulubei National Institute for Physics and Nuclear Engineering. The technical committee has the tasks of analysing the market, the regulations and the industry requirements and proposing new standards or revision for existing one. A table is given showing the number of IEC standards considered by TC 45, adopted RS - IEC standards (prepared/published) and planned for 2000/2001. Romania hosted IEC international plenary meetings in 1962 and 1974 and an IEC workshop 1997 with participation of specialists from USA, Sweden, Germany, France, Japan and Romania. As industry is striving to use more and more standard products, that means best quality and safety for less money, more than ever one have to convince the industry about the usefulness and specificity of the nuclear standards

  7. IEC Based D-3He Fusion for Space Propulsion

    International Nuclear Information System (INIS)

    Miley, George H.; Burton, R.; Richardson, N.; Shaban, Y.; Momota, Hiromu

    2002-01-01

    A preliminary system design is presented for a high performance 100-MWe manned space vehicle in the 500 metric ton class, based on Inertial Electrostatic Fusion (IEC), allowing trip times to the outer planets of several months. An IEC is chosen because it's simplified structure results in a very high power-to-weight ratio. D- 3 He fuel is used to give 14.7-MeV protons as a primary fusion reaction product. Direct conversion of proton energy to electricity is employed, providing a high efficiency. An IEC reactor with a proton energy gain (power in 14.7-MeV protons/input electric power) of 4 or better is assumed. Extrapolation of present laboratory scale IEC experiments to such conditions is possible theoretically, but faces several open issues that require further study such as stability under high-density conditions. The final thruster is based on an NSTAR-extrapolated krypton ion design with a specific impulse of 16,000 seconds and a total thrust of 1020 N. Round trip thrust time for mission set to Jupiter ΔV of 100 km/s is then ∼950 days. (authors)

  8. Can we use IEC 61850 for safety related functions?

    Directory of Open Access Journals (Sweden)

    Luca Rocca

    2016-08-01

    Full Text Available Safety is an essential issue for processes that present high risk for human beings and environment. An acceptable level of risk is obtained both with actions on the process itself (risk reduction and with the use of special safety systems that switch the process into safe mode when a fault or an abnormal operation mode happens. These safety systems are today based on digital devices that communicate through digital networks. The IEC 61508 series specifies the safety requirements of all the devices that are involved in a safety function, including the communication network. Also electrical generation and distribution systems are processes that may have a significant level of risk, so the criteria stated by the IEC 61508 applies. Starting from this consideration, the paper analyzes the safety requirement for the communication network and compare them with the services of the communication protocol IEC 61850 that represents the most used protocol for automation of electrical plants. The goal of this job is to demonstrate that, from the technical point of view, IEC 61850 can be used for implementing safety-related functions, even if a formal safety certification is still missing.

  9. Use of the TEM Cell for Compliance Testing of Emissions and Immunity, an IEC Perspective

    DEFF Research Database (Denmark)

    Bentz, Sigurd

    1996-01-01

    The current work of the IEC on preparing a standard for the use of TEM cells for compliance testing of emissions and immunity is reviewed. The requirements of TEM cells are related to the established procedures: “open area test site” and “shielded enclosure with area of uniform field”, respective...

  10. The Load Level of Modern Wind Turbines according to IEC 61400-1

    International Nuclear Information System (INIS)

    Freudenreich, K; Argyriadis, K

    2007-01-01

    The paper describes some effects on the load level of state-of-the art multi megawatt wind turbines introduced by the new edition of the standard IEC 61400-1:2005 W ind Turbines - Part 1: Design requirements . Compared to the previous edition, especially the extreme load determination has been modified by applying stochastic and statistical analyses. Within this paper the effect on the overall load level of wind turbines is demonstrated and occurring problems are discussed. Load simulations have been carried out for four state-of-the-art multi-megawatt wind turbines of different design concepts and from different manufacturers. The blade root bending moments and tip deflection have been determined by applying different extrapolation methods. Advantages and disadvantages of these methods and tail fittings for different load components and wind turbine technologies are discussed and interpreted. Further on, the application of the extreme turbulence model is demonstrated. The dependence of the load level on the turbulence intensity and control system, as well as the interaction with extrapolated loads is discussed and limitations outlined. The obtained load level is compared to the overall load level of the turbines according to the previous edition of the standard, IEC 61400-1:1999

  11. Development of an international standard on instruments setpoints based on ISA S67.04 - 1994

    International Nuclear Information System (INIS)

    Quinn, E.L.

    1996-01-01

    This is a summary of the application for and development of an international standard on instrument setpoints, based on the Instrument Society of America (ISA) Standard S67.04 - 1994. The forum this new standard was proposed in is the International Electrotechnique Commission (IEC), based in Geneva, Switzerland, which is the international commission which oversees electrical and instrumentation standards for all applications around the world. The Instrument Society of America (ISA) is a United States based Society for the advancement of instrumentation and controls related science and technology and has 30,000 members. A division within the ISA is the Standard and Practices board which has over 5000 members actively involved in standards development and approval. In 1994, the ISA SP67, Nuclear Power Plant Standards Committee authorized that the IEC be approached to develop and issue an IEC standard on Instrument Setpoints. This application was formally submitted in January, 1995 to the IEC and approved for ballot to member countries in June, 1995. Approval for standard development by IEC was received in October, 1995 and the first draft vas issued in February, 1996, and is currently under review by the IEC working group. It is very important to focus on the approach that the U.S. and other countries are taking toward development of IEC standards that can apply to all nuclear instrumentation applications around the world. By referencing IEC standards in design specification, vendors can be solicited from many different countries, thereby ensuring that the highest quality products can be used. This also offsets the need to specify individual standards in the specification, based on the country that each vendor solicited, represents. In summary, this standard development process, with support from the American National Standards Institute (ANSI) will assist U.S. suppliers in competing in the global market for products and services into the next century. (author)

  12. Correlation of Thermal and Microstructural Properties of an Al-0.60wt%Mg-0.25wt%Fe-0.05wt%Cu Alloy Unidirectionally Solidified

    Directory of Open Access Journals (Sweden)

    Pedro LAMARÃO

    2014-09-01

    Full Text Available This work aims to study the thermal, mechanical and microstructural properties of an Al-0.60 wt% Mg-0.25 wt% Fe- -0.05 wt% Cu alloy for application as an electrical conductor. The ingots were obtained by unidirectional horizontal casting, and were sectioned in specific positions to the production of test specimens destined to mechanical tests and microstructural characterization. As results, one can observe that it was possible to obtain experimental models of correlation between the average dimple diameters and thermal variables, demonstrating a trend on the formation of smaller fracture dimples where the cooling was more intense. As one can associate smaller dimples with greater ultimate tensile strength, it is important to understand this mechanism. DOI: http://dx.doi.org/10.5755/j01.ms.20.3.5015

  13. IEC-based neutron generator for security inspection system

    International Nuclear Information System (INIS)

    Miley, G.H.; Wu, L.; Kim, H.J.

    2005-01-01

    Use of a combined X-ray and neutron source for security inspections based on Inertial Electrostatic Confinement (IEC) fusion is discussed. Current inspection systems typically use X-ray techniques, but thermal neutron analysis (TNA) and fast neutron analysis (FNA), allow expanded detection of certain types of explosives. The integrated unit proposed here uses three separate IEC sources producing 14 and 2.45 MeV neutrons plus soft X-rays. This combination allows multiple detection methods with the composite signal analysis being done by a fuzzy logic system, significantly reducing false signals. (author)

  14. A collimator-converter system for IEC propulsion

    International Nuclear Information System (INIS)

    Momota, Hiromu; Miley, George H.

    2002-01-01

    The collimator-converter system extracts fusion power from D- 3 He fueled IEC devices and provides electricity needed to operate ionic thrusters and other-power components. The whole system is linear and consists of a series of collimator units at the center, magnetic expander units at both sides of the fusion units, followed by direct energy converters at both ends. This system is enclosed in a vacuum chamber with a magnetic channel provided by magnetic solenoids out of respective chambers. The fusion unit consists of an IEC fusion core, a pair of coils anti-parallel to the solenoid coils, and a stabilization coil that stabilizes the position of coil pair coils. The IEC fusion core is installed at the center of the pair coils. After the magnetic expander, velocities of fusion particles from D- 3 He fueled IEC units are directed to the magnetic channel, which guides energetic fusion particles as well as leaking unburned fuel components to a high-efficiency traveling wave direct energy converter (TWDEC). Leaking unburned fuel components are separated with a magnetic separator at the entrance of a direct energy converter and pumped out for further refueling. A TWDEC is made of an array of metallic meshed grids, each of which is connected to every terminal with an external transmission circuit. The transmission line couples to the direct energy converter. Substations for electricity, a cryogenic plant, and various power control systems are outside of the vacuum chamber. The length of the cylindrical system is essentially determined by the proton energy of 14.8 MeV and the radius should be large so as to reduce power flow density. The present system provides 250 MW f fusion power and converting it to 150 MW c electricity. Its size is 150 m(length)x6.6 m(diameter) in size and 185 tons in weight

  15. Modular structure of wind turbine models in IEC 61400-27-1

    DEFF Research Database (Denmark)

    Sørensen, Poul Ejnar; Andresen, Bjørn; Fortmann, Jens

    2013-01-01

    This paper presents the modular structure of wind turbine models to be published in a new standard IEC 61400-27 for “Electrical simulation models for wind power generation”. The purpose of this standardization work is to define generic simulation models for wind turbines (Part 1) and wind power...... plants (Part 2), which are intended for short-term power system stability analyses. Part 1 has passed the first committee draft stage, whereas Part 2 is in an early stage of development. Initially, the paper describes the interfaces between wind turbine, wind power plant and grid models, and then gives...... a more detailed description of the modular structure of the types of wind turbines that are included in Part 1....

  16. Adaptive Micro-Grid Operation Based on IEC 61850

    Directory of Open Access Journals (Sweden)

    Wei Deng

    2015-05-01

    Full Text Available Automatically identifying the new equipment after its integration and adjusting operation strategy to realize “plug and play” functionality are becoming essential for micro-grid operations. In order to improve and perfect the micro-grid “plug and play” function with the increased amount of equipment with different information protocols and more diverse system applications, this paper presents a solution for adaptive micro-grid operation based on IEC 61850, and proposes the design and specific implementation methods of micro-grid “plug and play” function and system operation mode conversion in detail, by using the established IEC 61850 information model of a micro-grid. Actual operation tests based on the developed IED and micro-grid test platform are performed to verify the feasibility and validity of the proposed solution. The tests results show that the solution can automatically identify the IEC 61850 information model of equipment after its integration, intelligently adjust the operation strategies to adapt to new system states and achieves a reliable system operation mode conversion.

  17. Critical issues for implementation of the standard NBR ISO/IEC 17025:2005 in Testing and Calibration Laboratory: case study at a public institution; Aspectos criticos para implantacao da norma NBR ISO/IEC 17025:2005 em laboratorio de ensaio e calibracao: estudo de caso em uma instituicao publica

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Denise Confar Carvalho de

    2013-07-01

    The public institution aims to promote excellence in public management to contribute to the quality of services provided to its customers and to increase competitiveness in the country, as well as its international projection. A technical barrier to trade that can lead to dissatisfaction and achieve the reputation of the institution is failing the test or calibration results and measurement data, thereby accreditation is regarded as the first essential step to facilitate the mutual acceptance of test results and calibration or measurement data. For recognition, laboratories need to demonstrate full compliance with both the sections of ISO/IEC 17025:2005, i.e. management and technical requirements. This research aims to discuss the critical aspects for implementation of ABNT NBR ISO / IEC 17025:2005 for calibration and testing of a Public Institution seeking accreditation of its laboratories with INMETRO, national accreditation body Laboratories. Besides getting preventive, corrective and improvement actions continues guidelines. Furthermore, the methodology used was to conduct a literature search and apply a questionnaire to identify the degree of agreement / disagreement of the foundations of the standard servers. Analysis of the results showed that the critical issues were: commitment, training, resources (infrastructure, human) and culture. (author)

  18. Wind power communication design and implementation of test environment for IEC61850/UCA2

    Energy Technology Data Exchange (ETDEWEB)

    Johnsson, A.; Svensson, J.

    2002-04-01

    Elforsk has sponsored a joint Swedish-Danish project aiming at finding and recommend a common solution for communication with wind power plants. The first stage of the work resulted in a requirement specification Functional Requirements on Communication System for Wind Turbine Applications. During the project a number of possible communication solutions were identified. The two most promising solutions have been tested in order to verify to what extent they fulfil the requirements in the specification. A version of the IEC 61850 standard based on the communication protocol MMS, has been tested at a wind power plant at Gotland, Sweden, and an OPC-interface has been tested in Denmark. This report includes a description of the design choices made for the test implementation of MMS, as well as a detailed description of the implementation of the IEC 61850/UCA2 software including information models and information exchange services. (BA)

  19. The suitability of the IEC 61400-2 wind model for small wind turbines operating in the built environment★

    Directory of Open Access Journals (Sweden)

    Evans Samuel P.

    2017-01-01

    Full Text Available This paper investigates the applicability of the assumed wind fields in International Electrotechnical Commission (IEC standard 61400 Part 2, the design standard for small wind turbines, for a turbine operating in the built environment, and the effects these wind fields have on the predicted performance of a 5 kW Aerogenesis turbine using detailed aeroelastic models developed in Fatigue Aerodynamics Structures and Turbulence (FAST. Detailed wind measurements were acquired at two built environment sites: from the rooftop of a Bunnings Ltd. warehouse at Port Kennedy (PK (Perth, Australia and from the small wind turbine site at the University of Newcastle at Callaghan (Newcastle, Australia. For both sites, IEC 61400-2 underestimates the turbulence intensity for the majority of the measured wind speeds. A detailed aeroelastic model was built in FAST using the assumed wind field from IEC 61400-2 and the measured wind fields from PK and Callaghan as an input to predict key turbine performance parameters. The results of this analysis show a modest increase in the predicted mean power for the higher turbulence regimes of PK and Callaghan as well as higher variation in output power. Predicted mean rotor thrust and blade flapwise loading showed a minor increase due to higher turbulence, with mean predicted torque almost identical but with increased variations due to higher turbulence. Damage equivalent loading for the blade flapwise moment was predicted to be 58% and 11% higher for a turbine operating at Callaghan and PK respectively, when compared with IEC 61400-2 wind field. Time series plots for blade flapwise moments and power spectral density plots in the frequency domain show consistently higher blade flapwise bending moments for the Callaghan site with both the sites showing a once-per-revolution response.

  20. COMBINING ITIL, COBIT AND ISO/IEC 27002 FOR STRUCTURING COMPREHENSIVE INFORMATION TECHNOLOGY FOR MANAGEMENT IN ORGANIZATIONS

    Directory of Open Access Journals (Sweden)

    Maico Gehrmann

    2012-09-01

    Full Text Available Several methodologies, tools and standards have been designed to help IT management within organizations. Companies seek, with the use of these mechanisms, the placement of IT management and organizational strategies, mainly to ensure that IT helps with the objectives of the business and the results of the organization. Despite the vast amount of options for tools, methodologies and standards available, when they are used independently, these are not sufficiently wide-ranging to meet all the needs of IT management. This document analyzes ITIL, COBIT and ISO/IEC 27002 methodologies through literature review, highlighting their similarities and differences through the comparison between them. From this analysis, an overall structure is proposed which uses a combination of ITIL, COBIT and ISO/IEC 27002 that can be used by any organization as a more comprehensive solution for the handling and servicing of IT management. As any process, there are positive and negative points. Some negative points of a methodology may be strengthened by the positive ones of other methodologies. This creates more efficient processes.

  1. Combining ITIL, COBIT and ISO/IEC 27002 for structuring comprehensive information technology for management in organizations

    Directory of Open Access Journals (Sweden)

    Maico Gehrmann

    2012-09-01

    Full Text Available Several methodologies, tools and standards have been designed to help IT management within organizations. Companies seek, with the use of these mechanisms, the placement of IT management and organizational strategies, mainly to ensure that IT helps with the objectives of the business and the results of the organization. Despite the vast amount of options for tools, methodologies and standards available, when they are used independently, these are not sufficiently wide-ranging to meet all the needs of IT management. This document analyzes ITIL, COBIT and ISO/IEC 27002 methodologies through literature review, highlighting their similarities and differences through the comparison between them. From this analysis, an overall structure is proposed which uses a combination of ITIL, COBIT and ISO/IEC 27002 that can be used by any organization as a more comprehensive solution for the handling and servicing of IT management. As any process, there are positive and negative points. Some negative points of a methodology may be strengthened by the positive ones of other methodologies. This creates more efficient processes.

  2. Impact Of IEC Intervention On Knowledge Regarding AIDS Amongst Senior Secondary School Children Of East Delhi

    Directory of Open Access Journals (Sweden)

    Bhasin S. K

    1999-01-01

    Full Text Available Research questions: 1. What is the level of awareness regarding HIV/AIDS amongst school children in East Delhi? 2. What is the impact of IEC intervention on the level of awareness regarding HIV/AIDS in these children? Objective: To find out the impact of IEC intervention on awareness regarding HIV/AIDS amongst senior secondary boys and girls in schools of East Delhi. Study design: Pre and post IEC interventional study. Settings: In four randomly selected senior secondary schools in East Delhi. Participants: 294 boys and 333 girls of class XI and XII in pre IEC group and 239 boys and 203 girls in post IEC group. Intervention: An IEC package of exhibition of posters, videotapes and intra group open discussion. Outcome variables: Proportion (prevalence of school children having correct knowledge of various aspects of HIV/AIDS after IEC intervention. Statistical analysis: Chi-square test. Results: IEC intervention significantly generated an enhancing effect on most aspects of their awareness towards HIV/AIDS among both boys and girls. Conclusions: There is an urgent need to impart health education for dispelling misconceptions regarding this disease.

  3. International standard for the charging of electric vehicles; Internationaler Standard fuer das Laden von Elektrofahrzeugen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Mathoy, A.

    2001-12-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on the situation regarding the standardisation of battery charging systems for electric vehicles. The advantages of an international standard both for users and manufacturers of electrically-powered vehicles are discussed. The work done in the IEC and CENELEC technical committees is reviewed. Developments achieved since 1999 are reviewed and further developments and work to be done are examined. The most important points in the IEC standard 61851 are looked at and various connector interfaces are described. Direct and inductive charging systems according to IEC 61980 are examined and the special situation in Italy, where power available in homes for the charging of electrical vehicles is more limited, is reviewed.

  4. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  5. Section for Standard and Patents - Standardization and Patents

    International Nuclear Information System (INIS)

    Wojtowicz, S.; Trechcinski, R.; Rybka, M.; Ryszkowska, A.; Wardaszko, J.

    1997-01-01

    Full text: The most important tasks of the Section in 1996 were: preparation of national standards and program of future work on standards for nuclear instrumentation and electronic equipment in nuclear engineering; organization of activities and participation in the meetings of the Commissions for Standardization No 173 Microprocessor Systems, No 266 Nuclear Instrumentation; giving opinions and expertises on national and international standards for equipment in nuclear engineering; cooperation with the Commission for Standardization No 246 Radiological Protection; control of inventiveness activity; The quality of the technical products is being improved by: a) selection of the proper types of interface systems, technical coordination and quality control; b) creation of standards at a high technical level; The Section works mainly for the Polish Committee for Standardization, the National Atomic Energy Agency, Association of Polish Electrical Engineers and Research Institutes in Poland. The activity of the Section is useful for all national institutions where backplane busses and nuclear electronic equipment is produced or used. The Section participates in the following international organizations: IEC (International Electrotechnical Commission) TC 45 (Nuclear Instrumentation); ISO/IEC Joint Technical Committee ISO/IEC JTCl SC26 (Microprocessor systems); ESONE (European Studies on Norms for Electronics); The section takes part in popularization of nuclear technology and instrumentation in the following ways: distribution of standards and technical documentation to national institutions dealing with nuclear apparatus; collecting and distributing technical information from international organizations (e.g. ESONE); organization of technical and scientific, national and international conferences (New Generation Nuclear Power Plants - September 96, QNX in Real World - January 96); participation in the technical conference organized by the Polish Committee for

  6. Standardization of Nuclear Instrumentation Applied in the NPP and in other nuclear installations

    International Nuclear Information System (INIS)

    Kusnowo, Arlinah; Darmawati, Suzie

    2002-01-01

    Nuclear power plant (NPP) and other nuclear installations have been recognized as applications needing very sophisticated technologies. One of technologies used in this all nuclear facilities is nuclear instrumentation. In order that NPP and other nuclear installations be operated safely, nuclear instrumentation requires standardization from design to its operation. Internationally, standardizations of nuclear instrumentation have been issued by IEC (International Electrotechnical Commission). Formulation of standard in nuclear instrumentation in IEC is carried out by Technical Committee (TC) 45. This paper describes briefly the standardization of nuclear instrumentation applied in Indonesia as Indonesian National Standard (SNI, Standard National Indonesia), standardization of nuclear instrumentation developed by TC 45, SC 45A, and SC 45B, as well as the possibility to adopt and apply those IEC standard in Indonesia

  7. Answering the request for emergency assistance worldwide. The Incident and Emergency Centre (IEC)

    International Nuclear Information System (INIS)

    2007-01-01

    In 2005, the IAEA announced the establishment of a fully integrated Incident and Emergency Centre (IEC). The functions of the IEC include coordinating prompt assistance to requesting States in the case of a nuclear security incident. As the global focal point for international preparedness, communication and response to nuclear and radiological incidents or emergencies irrespective of their cause, the IEC stands at the centre of coordinating effective and efficient activities worldwide. The IEC's work includes the evaluation of emergency plans and assistance in their development. The Centre also develops accident classifications based on plant conditions and supports effective communication between neighbouring countries. In addition, it develops various response procedures and facilitates national exercises on response to reactor emergencies. This includes training a broad range of IAEA staff to respond to emergencies as well as training of external experts. Response to incidents and emergencies can involve the exchange of information, provision of advice and/or the coordination of field response. In order to coordinate a global response, the IEC hosts a Response Assistance Network (RANET) under which Member States, Parties to the Emergency Conventions and relevant international organizations are able to register their response capabilities. This network aims to facilitate assistance in case of a nuclear or radiological incident or emergency in a timely and effective manner. An important component of the global emergency response system is the notification and reporting arrangements and systems operated by the IEC. The IEC operates systems that are reliable and secure. Member States, Non-Member States and international organizations have historically reported events and requests for assistance to the IAEA through the ENATOM arrangements using the ENAC web site, phone or fax. Under these arrangements, States have nominated Competent Authorities and National Warning

  8. 76 FR 49237 - Energy Conservation Program: Test Procedures for Residential Clothes Washers

    Science.gov (United States)

    2011-08-09

    ...) Standard 62301, ``Household electrical appliances--Measurement of standby power'' (Second Edition). DOE... possible, please submit all items on a CD. It is not necessary to include printed copies. 4. Hand Delivery.... The IEC published IEC Standard 62301, Edition 2.0 2011-01 (``IEC Standard 62301 (Second Edition)'' or...

  9. Maturity index on reliability: covering non-technical aspects of IEC61508 reliability certification

    International Nuclear Information System (INIS)

    Brombacher, A.C.

    1999-01-01

    One of the more recent developments in the field of reliability and safety is the realisation that these aspects are not only a function of the product itself, but also of the organisation realising this product. A second development is a trend from an often predominantly qualitative analysis towards a quantitative analysis. In contrast to the (older) DIN 0801, the (more recent) IEC61508 requires, on product level, also a quantitative analysis and, on organisational level, an assessment of the lifecycle of a product by analysing the (maturity of the) relevant business processes (DIN V VDE 0801. Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, 1990; DIN V 0801. Grundlegende Sicherheitsbetrachtungen fuer MSR-Schutzeinrichtungen, 1994; DIN V VDE 0801 A1. Grundsaetze fuer Rechner in Systemen mit Sicherheitsaufgaben, Aenderung A1, 1994; IEC 61508 Functional Safety of electrical/electronic/programmable electronic safety-related systems, draft 4.0, 1997). The IEC standard 61508 covers: (i) technical aspects, both on a quantitative and a qualitative level; (ii) organisational aspects, both on aspects of maturity of business processes (quantitative) and on aspects of the definition and application of procedures (qualitative). This paper shows the necessity for an analysis on all aspects in a safety certification process, and presents an overview of the available tools and techniques for the various quadrants. As methods and tools for especially quadrant C are currently unavailable, this paper will propose a method to assess and improve the maturity of an organisation on reliability management: the maturity index on reliability (MIR)

  10. Air kerma standardization for diagnostic radiology in a secondary standard laboratory

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Lopes, Ricardo T.

    2009-01-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Brazilian Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. The objective of this work was to implement the standardization of the air kerma for the unatenuated qualities (RQR) of IEC 61267 in the National Laboratory of Metrology of the Ionizing Radiations (LNMRI) of the Institute of Radiation Protection and Dosimetry (IRD). Technical procedures were developed together with uncertainty budget. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. (author)

  11. IEC fusion: The future power and propulsion system for space

    International Nuclear Information System (INIS)

    Hammond, Walter E.; Coventry, Matt; Miley, George H.; Nadler, Jon; Hanson, John; Hrbud, Ivana

    2000-01-01

    Rapid access to any point in the solar system requires advanced propulsion concepts that will provide extremely high specific impulse, low specific power, and a high thrust-to-power ratio. Inertial Electrostatic Confinement (IEC) fusion is one of many exciting concepts emerging through propulsion and power research in laboratories across the nation which will determine the future direction of space exploration. This is part of a series of papers that discuss different applications of the Inertial Electrostatic Confinement (IEC) fusion concept for both in-space and terrestrial use. IEC will enable tremendous advances in faster travel times within the solar system. The technology is currently under investigation for proof of concept and transitioning into the first prototype units for commercial applications. In addition to use in propulsion for space applications, terrestrial applications include desalinization plants, high energy neutron sources for radioisotope generation, high flux sources for medical applications, proton sources for specialized medical applications, and tritium production

  12. Development of Electro-Optical Standard Processes for Application

    Science.gov (United States)

    2011-11-01

    IEC - 17025 (Reference 1.11c). The 17025 standard, which is part of the ISO -9000 series and is more familiar to industry, replaced ISO Guide 25, which...Even if the EO/IR community elects to follow a path defined by ISO / IEC 17025 , the modified criteria should be considered as a starting point. (See... 17025 and its U.S. equivalent, ANSI/NCSL Z540.3-2006. ISO / IEC - 17025 differs significantly in organization, but contains very similar quality

  13. Evaluation of the signal-to-noise ratio (SNR) in a CR system and establishment of RQR-M and RQA-M IEC reference radiations in mammography

    International Nuclear Information System (INIS)

    Rosado, Paulo H.G.; Nogueira, Maria S.; Dantas, Marcelino V.A.; Santana, Priscila do C.

    2009-01-01

    In this work, the radiation condition RQR-M e RQA-M of IEC were established in the Siemens Mammomat 3000 mammography equipment. The standard radiation condition are described in terms of: emitting target of molybdenum, percentage ripple not more that 4%, total filtration of 0,032 ± 0,002 mm of molybdenum and specific values of first half-value layer. The results show that the values of parameters were in the range that the IEC recommends. Only the RQAM-3 the value of CSR was not in agreement of the value recommend, and was necessary a additions of 0,1 mm Al in the x-ray tube. After this, the signal noise ratio (SNR) of de Computer radiography (CR) system was evaluated in the reference qualities of RQR-M e RQA-M. For SNR the RQR-M mode of exposure was done with both the 20 mAs and automatic one. To RQA-M the exposure was done with 100 mAs. The variations of the values of SNR were approximated 4%. The tests were done with CR model CR850 made from Kodak and 40 mm of PMMA. (author)

  14. IGF-IEc expression is increased in secondary compared to primary foci in neuroendocrine neoplasms.

    Science.gov (United States)

    Alexandraki, Krystallenia I; Philippou, Anastassios; Boutzios, Georgios; Theohari, Irini; Koutsilieris, Michael; Delladetsima, Ioanna Kassiani; Kaltsas, Gregory A

    2017-10-03

    Different Insulin-like growth factor-I (IGF-I) mRNA transcripts are produced by alternative splicing and particularly the IGF-IEc isoform has been implicated in the development and/or progression of various types of cancer. In the present study, we examined the potential role of IGF-IEc expression as a new immunohistochemical marker of aggressiveness in neuroendocrine neoplasms (NENs). We utilized immunohistochemical analysis in tissue specimens of 47 patients with NENs, to evaluate the expression of IGF-IEc (%) and Ki-67 proliferation index (%). Specimens from patients with tumors of different tissue origin, of either primary or metastatic lesions and of different grade were examined. Cytoplasmic IGF-IEc staining was found in 23 specimens of NENs or NECs: 10 pancreatic, 4 small bowel, 3 gastric, 1 lung, 1 uterine and 4 poorly differentiated of unknown primary origin. Ki-67 and IGF-IEc expression was positively correlated in all the samples studied (r=0.31, p=0.03). IGF-1Ec expression was more prevalent in specimens originating from metastatic foci with high Ki-67 compared to primary sites with low Ki-67 expression (p=0.036). These findings suggest a possible role of IGF-IEc in NEN tumorigenesis and progression to metastases that could be used as an additional new marker of a more aggressive behavior and a potential drugable target.

  15. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    International Nuclear Information System (INIS)

    Voytchev, M.; Chiaro, P.; Radev, R.

    2006-01-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'

  16. Sophisticated Calculation of the 1oo4-architecture for Safety-related Systems Conforming to IEC61508

    International Nuclear Information System (INIS)

    Hayek, A; Al Bokhaiti, M; Schwarz, M H; Boercsoek, J

    2012-01-01

    With the publication and enforcement of the standard IEC 61508 of safety related systems, recent system architectures have been presented and evaluated. Among a number of techniques and measures to the evaluation of safety integrity level (SIL) for safety-related systems, several measures such as reliability block diagrams and Markov models are used to analyze the probability of failure on demand (PFD) and mean time to failure (MTTF) which conform to IEC 61508. The current paper deals with the quantitative analysis of the novel 1oo4-architecture (one out of four) presented in recent work. Therefore sophisticated calculations for the required parameters are introduced. The provided 1oo4-architecture represents an advanced safety architecture based on on-chip redundancy, which is 3-failure safe. This means that at least one of the four channels have to work correctly in order to trigger the safety function.

  17. Fiscal 1999 technical achievement report. Research and development project on the quickly effective international standards creation (Standardization of safety of light emitting diode or the like); 1999 nendo sokkogata kokusai hyojun sosei kenkyu kaihatsu jigyo seika hokokusho. Hakko diode nado no anzensei ni kansuru hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    Since radiation of a laser diode (LD) is quite different from that of a light emitting diode (LED), evaluating their safety under one and the same standard (criterion) is questionable. The International Electrotechnical Commission (IEC), however, treats them in the same way. For the remedy of such contradiction and for the clarification of difference between the two devices in terms of radiation characteristics, they were quantitatively measured for spatial coherence and further measured for coherence dependency of their beam diameters. Well-supported threshold levels were prepared and biological tests were conducted for proposing a revision of the LED safety standard (IEC). As for the safety of equipment with built-in infrared devices, a measurement method was prepared as IEC61913 and devices are already at the CVD (chemical vapor deposition) stage. The result will be placed before the IEC/TC76 committee for deliberation of IEC60825-1 revision. Furthermore, to establish alignment between IEC and ISO (International Standardization Organization) in terms of laser-aided measurement which is the foundation for such committee deliberation, an ISO/IEC international joint group was created, and a technical recommendation was compiled and presented to the two standardizing organizations. (NEDO)

  18. Hybrid Multi-Agent Control in Microgrids: Framework, Models and Implementations Based on IEC 61850

    Directory of Open Access Journals (Sweden)

    Xiaobo Dou

    2014-12-01

    Full Text Available Operation control is a vital and complex issue for microgrids. The objective of this paper is to explore the practical means of applying decentralized control by using a multi agent system in actual microgrids and devices. This paper presents a hierarchical control framework (HCF consisting of local reaction control (LRC level, local decision control (LDC level, horizontal cooperation control (HCC level and vertical cooperation control (VCC level to meet different control requirements of a microgrid. Then, a hybrid multi-agent control model (HAM is proposed to implement HCF, and the properties, functionalities and operating rules of HAM are described. Furthermore, the paper elaborates on the implementation of HAM based on the IEC 61850 Standard, and proposes some new implementation methods, such as extended information models of IEC 61850 with agent communication language and bidirectional interaction mechanism of generic object oriented substation event (GOOSE communication. A hardware design and software system are proposed and the results of simulation and laboratory tests verify the effectiveness of the proposed strategies, models and implementations.

  19. Development of international standards for instrumentation used for detection of illicit trafficking of radioactive material

    Energy Technology Data Exchange (ETDEWEB)

    Voytchev, M. [Institut de Radioprotection et de Surete Nucleaire (IRSN/DSU/SERAC/CTHIR), 91 - Gif sur Yvette (France); Chiaro, P. [Oak Ridge National Lab., TN (United States); Radev, R. [LLNL, Livermore, CA (United States)

    2006-07-01

    Subcommittee 45 B 'Radiation Protection Instrumentation' of the International Electrotechnical Commission (I.E.C.) is charged with the development of international standards for instrumentation used for monitoring of illicit trafficking of radioactive material through international boarders and territories, as well as inside countries. Currently three I.E.C. standards are in advanced stages of development. They are expected to be approved and published in 2006-2007. The international participation and the main characteristics of the following three standards are discussed and presented: I.E.C. 62327 'Hand-held Instruments for the Detection and Identification of Radionuclides and Additionally for the Indication of Ambient Dose Equivalent Rate from Photon Radiation', I.E.C. 62401 'Alarming Personal Radiation Devices for Detection of Illicit Trafficking of Radioactive Material' and I.E.C. 62244 'Installed Radiation Monitors for the Detection of Radioactive and Special Nuclear Materials at National Borders'.

  20. Plan de implementación de la ISO/IEC 27001:2013

    OpenAIRE

    Gorriti Aranguren, Iñaki

    2015-01-01

    En el desarrollo del proyecto se analizaron las directrices establecidas en la norma ISO/IEC 27001:2013, que especifica los requisitos necesarios para establecer, implantar, mantener y mejorar un SGSI mediante un proceso de mejora continua. In the development there were analyzed the directives established in the norm ISO/IEC27001:2013, which specifies the necessary requirements to establish, to implement, to support and to improve a SGSI by means of a process of constant improvement. En...

  1. Assessment of Information Security Management System based on ISO/IEC 27001:2013 On Subdirectorate of Data Center and Data Recovery Center in Ministry of Internal Affairs

    Science.gov (United States)

    Kurnianto, Ari; Isnanto, Rizal; Widodo, Aris Puji

    2018-02-01

    Information security is a problem effected business process of an organization, so it needs special concern. Information security assessment which is good and has international standard is done using Information Security Management System (ISMS) ISO/IEC 27001:2013. In this research, the high level assessment has been done using ISO/IEC 27001:2013 to observe the strength of information secuity in Ministry of Internal Affairs. The research explains about the assessment of information security management which is built using PHP. The input data use primary and secondary data which passed observation. The process gets maturity using the assessment of ISO/IEC 27001:2013. GAP Analysis observes the condition now a days and then to get recommendation and road map. The result of this research gets all of the information security process which has not been already good enough in Ministry of Internal Affairs, gives recommendation and road map to improve part of all information system being running. It indicates that ISO/IEC 27001:2013 is good used to rate maturity of information security management. As the next analyzation, this research use Clause and Annex in ISO/IEC 27001:2013 which is suitable with condition of Data Center and Data Recovery Center, so it gets optimum result and solving problem of the weakness information security.

  2. Establishment of qualities mammography according to the standard IEC-61267 in the laboratory of metrology of ionizing radiation of the National Center of Dosimetry and enlargement of the accreditation by ENAC; Establecimiento de las calidades de mamografia segun la norma IEC-61267 en el laboratorio de metrologia de radiaciones ionizantes del centro nacional de dosimetria (CND) y proceso de ampliacion de su acreditacion por ENAC

    Energy Technology Data Exchange (ETDEWEB)

    Roig Petit, F.; Mestre de Juan, V.; Alabau Albors, J.; Palma Copete, J.; Ruiz Rodriguez, J. C.; Pons Mocholi, S.

    2013-07-01

    The extension of the accreditation of the laboratory of the National Center Dosimetry (No. 58/LC10.036) by the national accreditation entity (ENAC), according to the ISO 17025 standard [2], for the standard qualities of mammography by the IEC 61267 comes to meet part of the needs that demand our health care environment in terms of radiation measuring instruments calibration. This work intends to publicize this enlargement commenting on the different phases of the process to get the accreditation. (Author)

  3. Comparison of EMI/RFI requirements to qualify the equipment for nuclear power plant. (RG 1.180, EPRI TR 102323, IEC 62003 and GB/T 11684)

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Tae Heon [Korea Testing Laboratory, Ansan (Korea, Republic of); Kim, Jong Seog [Research Institute of Korea Electric Power Corporation, Daejeon (Korea, Republic of); Seo, Jeong Ho; Cho, Kyoung Youn [Korea Electric Association, Seoul (Korea, Republic of)

    2011-05-15

    One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I and C) systems in recent years is electromagnetic compatibility (EMC). In some reports for nuclear power plant (NPP), electromagnetic interference (EMI), radio frequency interference (RFI), and power surges have been identified as environmental conditions that can affect the performance of safety-related electrical equipment. There are mainly two reference guides for applying to qualify EMI/RFI requirements of the equipment used in a NPP: US NRC RG 1.180 and EPRI TR 102323. Recently, IEC published the standard for the equipment in the NPP, IEC 62003. This paper has compared the requirements of these, including comparing of the requirement of the Chinese national standard, GB/T 11684

  4. Comparison of EMI/RFI requirements to qualify the equipment for nuclear power plant. (RG 1.180, EPRI TR 102323, IEC 62003 and GB/T 11684)

    International Nuclear Information System (INIS)

    Jang, Tae Heon; Kim, Jong Seog; Seo, Jeong Ho; Cho, Kyoung Youn

    2011-01-01

    One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I and C) systems in recent years is electromagnetic compatibility (EMC). In some reports for nuclear power plant (NPP), electromagnetic interference (EMI), radio frequency interference (RFI), and power surges have been identified as environmental conditions that can affect the performance of safety-related electrical equipment. There are mainly two reference guides for applying to qualify EMI/RFI requirements of the equipment used in a NPP: US NRC RG 1.180 and EPRI TR 102323. Recently, IEC published the standard for the equipment in the NPP, IEC 62003. This paper has compared the requirements of these, including comparing of the requirement of the Chinese national standard, GB/T 11684

  5. IMPLEMENTATION OF SECURITY CONTROLS ACCORDING TO ISO/IEC 27002 IN A SMALL ORGANISATION

    Directory of Open Access Journals (Sweden)

    MATÚŠ HORVÁTH

    2009-12-01

    Full Text Available Information security should be today a key issue in any organization. With the implementation of information security management system (ISMS the organization can identify and reduce risks in this area. This the area of information security management covers a numbers of ISO / IEC 27000 standards, which are based on best practice solutions. However, smaller organizations are often discourages with the implementation of these systems, because of fear of high cost and complexity. Especially due to the fact that the standards does not strictly require implementation of all security controls it is possible to implement these systems in small-size organizations. In this article, we want to point on this fact through describing practical experience with ISMS implementation in small-size organization.

  6. International Electrotechnical Commission standards and French material control standards

    International Nuclear Information System (INIS)

    Furet, J.; Weill, J.

    1978-01-01

    There are reported the international standards incorporated into the IEC Subcommitee 45 A (Nuclear Reactor Instrumentation) and the national standards elaborated by the Commissariat a l'Energie Atomique, CEA, Group of normalized control equipment, the degree of application of those being reported on the base design, call of bids and exploitation of nuclear power plants. (J.E. de C)

  7. Mechanical Properties of 0.14wt%C – 0.56wt%Mn – 0.13wt%Si ...

    African Journals Online (AJOL)

    Effect of intercritical heat treatment on 0.14wt%C – 0.56wt%Mn – 0.13wt%Si structural steel has been investigated. Specimens for single quenching and those for double quenching were prepared for intercritical heat treatment. The heat treatment of the experimental steel was based on intercritical annealing in the ferrite + ...

  8. Scaling of the Inertial Electrostatic Confinement (IEC) for near-term thrusters and future fusion propulsion

    International Nuclear Information System (INIS)

    Miley, G.; Bromley, B.; Jurczyk, B.; Stubbers, R.; DeMora, J.; Chacon, L.; Gu, Y.

    1998-01-01

    Inertial Electrostatic Confinement (IEC) is a unique approach to fusion and plasma energy systems that was conceptualized in the 1960s (Hirsch 1967) and has been the focus of recent development in the 1990s (Miley et al. 1995a). In the interests of space power and propulsion systems, conceptual rocket design studies (Bussard and Jameson 1994, Miley et al. 1995b) using the IEC have predicted excellent performance for a variety of space missions, since the power unit avoids the use of magnets and heavy drives resulting in a very high, specific impulse compared to other fusion systems. In their recent survey of prior conceptual design studies of fusion rockets, Williams and Borowski (1997) found that the Bussard IEC conceptual study (the ''QED'' engine) offered a thrust-to-weight ratio of 10 milli-g's, a factor of five higher than conventional magnetic confinement concepts and even slightly above anti-proton micro fission/fusion designs. Thus there is considerable motivation to study IEC concepts for eventual space applications. However, the physics feasibility of the IEC still requires experimental demonstration, and an expanded data base is needed to insure that a power unit can in fact be built

  9. Qualidade e educação superior: a norma de qualidade para a aprendizagem, educação e formação: ISO/IEC 19796-1 = Quality and Higher Education: the standard ISO/IEC 19796-1 for learning, education and training

    Directory of Open Access Journals (Sweden)

    Viebrantz, Rosalir

    2009-01-01

    Full Text Available Em 2005, uma nova norma de qualidade para a aprendizagem, educação e formação, a ISO/IEC 19796-1, foi publicada. O objetivo desta norma é orientar as organizações educacionais e desenvolver sistemas de qualidade e melhorar a qualidade dos seus processos, produtos e serviços. Este artigo busca entender a norma com base em conceitos de qualidade e na tendência à garantia da qualidade. A ISO/IEC é apresentada de forma sucinta, mostrando a metodologia e suas vantagens para as organizações educacionais. É ressaltado que a norma é um modelo de referência e necessita ser adaptada às necessidades e exigências de cada organização

  10. ISO/IEC 17025–2017 "New requirements to the competence of test and calibration laboratories"

    Directory of Open Access Journals (Sweden)

    Baranova P. O.

    2018-05-01

    Full Text Available due to the continuous improvement of the regulatory framework, there is a growing demand for laboratory centers that provide services in the field of testing. The relevance of the topic lies in the transition of laboratories to the new version of ISO/IEC 17025–2017 «General requirements for the competence of test and calibration laboratories». The article compares two versions of the standard, reveals differences and similarities. And changes in the gradation of changes are also highlighted.

  11. RBMK nuclear reactors: Proposals for instrumentation and control improvements to enhanced safety and availability. IEC technical report of type 3. Working material

    International Nuclear Information System (INIS)

    1995-01-01

    The present material presents a CD+V draft report ''RBMK nuclear reactors: Proposals for instrumentation and control improvements to enhance safety and availability'' prepared by the Joint IEC/IAEA team during 1993-1995. Experience has demonstrated the need to improve the safety instrumentation of the RBMK type reactors using well proven modern technology. The working group identified the upgrades and changes of the highest priority based on the evaluation of the RBMK systems and the events where the instrumentation was found to be inadequate for safe operation. The subjects discussed in this document were not selected on a systematic basis but were selected by the IEC and IAEA experts as considered to be appropriate to the activities of the IEC and for which technical experience was available. The items identified therefore do not reflect any ranking of the safety issues or any priority or impact on safety of any of the measures were they to be implemented. Many important safety issued and areas where physical measures are required to improve safety have been omitted and indeed not even acknowledged in this document. The recommendations presented in the document differ from those normally produced by the IEC in the form of standards as they are of a transitory nature and some have already been overtaken by the continuing process of improvements to plant safety. Figs and tabs

  12. Assessment of Information Security Management System based on ISO/IEC 27001:2013 On Subdirectorate of Data Center and Data Recovery Center in Ministry of Internal Affairs

    Directory of Open Access Journals (Sweden)

    Kurnianto Ari

    2018-01-01

    Full Text Available Information security is a problem effected business process of an organization, so it needs special concern. Information security assessment which is good and has international standard is done using Information Security Management System (ISMS ISO/IEC 27001:2013. In this research, the high level assessment has been done using ISO/IEC 27001:2013 to observe the strength of information secuity in Ministry of Internal Affairs. The research explains about the assessment of information security management which is built using PHP. The input data use primary and secondary data which passed observation. The process gets maturity using the assessment of ISO/IEC 27001:2013. GAP Analysis observes the condition now a days and then to get recommendation and road map. The result of this research gets all of the information security process which has not been already good enough in Ministry of Internal Affairs, gives recommendation and road map to improve part of all information system being running. It indicates that ISO/IEC 27001:2013 is good used to rate maturity of information security management. As the next analyzation, this research use Clause and Annex in ISO/IEC 27001:2013 which is suitable with condition of Data Center and Data Recovery Center, so it gets optimum result and solving problem of the weakness information security.

  13. The stored energy in processed Cu-0.4 wt.%Cr-0.12 wt.%Zr-0.02 wt.%Si-0.05 wt.%Mg

    International Nuclear Information System (INIS)

    Li, X.F.; Dong, A.P.; Wang, L.T.; Yu, Z.; Meng, L.

    2011-01-01

    Research highlights: → The crystal orientation in processed Cu-0.4 wt.%Cr-0.12 wt.%Zr-0.02 wt.%Si-0.05 wt.%Mg is deviating from the as-cast specimens and microstrain of the alloy is gradually increasing as the draw ratio rising before η ≤ 6.7. → The dynamic recovery has taken place as 6.7 texture is formed with the draw ratio rising. Meanwhile, the stored energy also increases with the draw ratio rising and a peak is reached with draw ratio of 6.7. The release of stored energy is primarily due to the decrease of dislocation density. The flow stress estimated from the stored energy has a similar variation trend with the measured data with a stress difference ∼20 to 120 MPa. The main strengthening effect is attributed to dislocation mechanism.

  14. Direct energy conversion for IEC fusion for space applications

    International Nuclear Information System (INIS)

    Momota, Hiromu; Nadler, Jon; Miley, George H.

    2000-08-01

    The paper describes a concept of extracting fusion power from D- 3 He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a separator and a traveling wave converter. A separator separates low energy ions and electron from the 14.7 MeV fusion protons and then converts their energy into electricity. In the traveling wave direct energy converter, fusion protons are modulated to form bunches. It couples with a transmission line to couple AC power out. The overall conversion efficiency of this system, combined with E- 3 He IEC cores, is estimated as high as 60%. (author)

  15. Direct energy conversion for IEC fusion for space applications

    Energy Technology Data Exchange (ETDEWEB)

    Momota, Hiromu; Nadler, Jon [National Inst. for Fusion Science, Toki, Gifu (Japan); Miley, George H. [Fusion Studies Laboratory, Urbana, IL (United States)

    2000-08-01

    The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a separator and a traveling wave converter. A separator separates low energy ions and electron from the 14.7 MeV fusion protons and then converts their energy into electricity. In the traveling wave direct energy converter, fusion protons are modulated to form bunches. It couples with a transmission line to couple AC power out. The overall conversion efficiency of this system, combined with E-{sup 3}He IEC cores, is estimated as high as 60%. (author)

  16. Standards, documents of relevance and directives in individual monitoring: is European individual monitoring in compliance with standards?

    International Nuclear Information System (INIS)

    Fantuzzi, E.

    2005-01-01

    Full text: Individual monitoring services in Europe do not comply with the same legal or approval requirements. Anyway, a degree of harmonization existing in individual monitoring practices in Europe has been achieved mainly thank to documents as standards or international recommendations, which with a different weight, represent invaluable vehicles of condensed information transfer. However, implementation of standards is not straightforward and harmonization is not directly a consequence. Somehow, 'harmony' is needed also in standards: IEC and ISO standards on performance requirements for dosemeters sometimes have different approaches (i.e. performance criteria). If used for approval, passing one will not necessarily mean passing all. Moreover, standards do not all refer to reliability, and therefore being in compliance with standards does not itself assure that dose results are reliable. This might apply only to ISO/IEC17025 'quality' standard, which represents the best available tool for the quality of laboratory work and somehow include all technical and management requirements. When accredited according to ISO/IEC17025, an Individual Monitoring Service (IMS) fulfils standards. Standards are not the only reference documents for an IMS. EURADOS working group on 'Harmonization of Individual Monitoring in Europe', who has been active in the years 2001-2004, suggested a classification of publication on individual monitoring, distinguishing between standards and documents of relevance, which can be both national and international. A standard, unlike a textbook or technical publication, does not cover the experience and opinion of one or few individuals only, but the consensus of the entire scientific and technical community concerned. Most of the standards applicable to individual monitoring are published by IEC or ISO, or both together. However, it has to be kept in mind that ISO and IEC standards, for example, are meant for manufactures and industry, which do not

  17. The status of Korean nuclear codes and standards

    International Nuclear Information System (INIS)

    Namha Kim; Jong-Hae Kim

    2005-01-01

    Korea Electric Power Industry Code (KEPIC), a set of integrated standards applicable to the design, construction and operation of electric power facilities including nuclear power plants, has been developed on the basis of referring to the prevailing U.S. codes and standards which had been applied to the electric power facilities in Korea. Being the developing and managing organization of KEPIC, Korea Electric Association (KEA) published its first edition in 1995, the second in 200,0 and is expected to publish the 2005 edition. KEPIC was applied to the construction of Ulchin Nuclear Units 5 and 6 in 1997, and will be applicable to the construction of forthcoming nuclear power plants in Korea. Along with the effectuation of the Agreement on Technical Barriers to Trade (TBT) in 1995, the international trend related to codes and standards is changing rapidly. The KEA is, therefore, making its utmost efforts so as for KEPIC to keep abreast with the changing environment in international arena. KEA notified ISO/IEC Information Centre of its acceptance of the Code of Good Practice in the Agreement on TBT. The 2005 KEPIC edition will be retrofitted according to the ISO/IEC Guide 21- Adoption of International Standards as regional or national standards. KEA's efforts will help KEPIC correspond with international standards such as ISO/IEC standards, and internationally recognized standards such as ASME codes and standards. (authors)

  18. Modification effect of Ni-38 wt.%Si on Al-12 wt.%Si alloy

    International Nuclear Information System (INIS)

    Wu Yuying; Liu Xiangfa; Jiang Binggang; Huang Chuanzhen

    2009-01-01

    Modification effect of Ni-38 wt.%Si on the Al-12 wt.%Si alloy has been studied by differential scanning calorimeter, torsional oscillation viscometer and liquid X-ray diffraction experiments. It is found that there is a modification effect of Ni-38 wt.%Si on Al-12 wt.%Si alloy, i.e. primary Si can precipitate in the microstructure of Al-12 wt.%Si alloy when Ni and Si added in the form of Ni-38 wt.%Si, but not separately. Ni-38 wt.%Si alloy brings 'genetic materials' into the Al-Si melt, which makes the melt to form more ordering structure, promotes the primary Si precipitated. Moreover, the addition of Ni-38 wt.%Si, which decreases the solidification supercooling degree of Al-12 wt.%Si alloy, is identical to the effect of heterogeneous nuclei.

  19. Modification effect of Ni-38 wt.%Si on Al-12 wt.%Si alloy

    Energy Technology Data Exchange (ETDEWEB)

    Wu Yuying [Key Laboratory of Liquid Structure and Heredity of Materials, Ministry of Education, Shandong University, Ji' nan 250061 (China)], E-mail: wyy532001@163.com; Liu Xiangfa [Key Laboratory of Liquid Structure and Heredity of Materials, Ministry of Education, Shandong University, Ji' nan 250061 (China); Shandong Binzhou Bohai Piston Co., Ltd., Binzhou 256602, Shandong (China); Jiang Binggang [Key Laboratory of Liquid Structure and Heredity of Materials, Ministry of Education, Shandong University, Ji' nan 250061 (China); Huang Chuanzhen [School of Mechanical Engineering, Shandong University, Jinan 250061 (China)

    2009-05-27

    Modification effect of Ni-38 wt.%Si on the Al-12 wt.%Si alloy has been studied by differential scanning calorimeter, torsional oscillation viscometer and liquid X-ray diffraction experiments. It is found that there is a modification effect of Ni-38 wt.%Si on Al-12 wt.%Si alloy, i.e. primary Si can precipitate in the microstructure of Al-12 wt.%Si alloy when Ni and Si added in the form of Ni-38 wt.%Si, but not separately. Ni-38 wt.%Si alloy brings 'genetic materials' into the Al-Si melt, which makes the melt to form more ordering structure, promotes the primary Si precipitated. Moreover, the addition of Ni-38 wt.%Si, which decreases the solidification supercooling degree of Al-12 wt.%Si alloy, is identical to the effect of heterogeneous nuclei.

  20. EXPERIMENTAL RESEARCHES OF ELECTRO-THERMAL RESISTIBILITY OF SEND-OFFS AND CABLES TO ACTION RATIONED ON THE INTERNATIONAL STANDARD OF IEC 62305-1-2010 OF APERIODIC IMPULSE OF CURRENT OF ARTIFICIAL LIGHTNING

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2016-03-01

    Full Text Available Purpose. Experimental researches of electro-thermal resistibility of cable-explorer products, applied in the power electric circuits of objects of electric-power industry, to action on its copper and aluminum parts bearings a current rationed on the International Standard of IEC 62305-1-2010 aperiodic impulse 10/350 μs of current of artificial lightning. Methodology. Electrophysics bases of technique of high tensions and high pulsed currents (HPC, and also scientific and technical bases of planning of devices of high-voltage impulsive technique and measuring HPC in them. Results. Experimental a way the quantitative levels of maximal values maximum of possible and critical closenesses of aperiodic impulse 10/350 μs of current of artificial lightning with rationed on the international standard of IEC 62305-1-2010 peak-temporal parameters and admittances on them in copper (aluminum parts bearings a current of send-offs and cables with a polyethylene (PET and polyvinylchloride (PVCH isolation. Originality. First in world practice on the unique powerful high-voltage generator of HPC of artificial lightning experimental researches of resistibility to lightning of pre-production models of send-offs (cables are conducted with copper (aluminum tendons, PET and PVCH by an isolation, in-use in power electric circuits of electric-power industry objects. Practical value. The use in practice of protecting from lightning of the got results will allow substantially to promote functional and fire-prevention safety of engineering communications of objects of industrial electroenergy in the conditions of action on them of short shots of linear lightning.

  1. Internal Audit Status For ISO 9001 And ISO/ IEC 17025 In Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Fazila Said; Nurul Huda Mudri; Nik Arlina Ali

    2012-01-01

    The development of MS ISO 9001 and MS ISO/ IEC 17025 in Malaysian Nuclear Agency is the basic step to enhance and improve the Quality Management System (QMS) for processes and laboratories that involve customers and suppliers in delivering products and services. The effectiveness of QMS is monitored by Research and Innovation Management Centre (RIMC) to ensure that all activities related to audit such as Internal Audit are well organized and implemented as documented in quality manual and procedure. This paper will discuss the status of internal audit for processes that implement MS ISO 9001 and laboratories that accredited with MS/ ISO IEC 17025 in year 2008, 2009 and 2010. The total of non-conformance (nc) and opportunity for improvement (ofi) for processes and laboratories and their numbers as per clause in MS ISO 9001 and MS ISO/ IEC 17025 are the indicators that reflects the effectiveness of QMS. Then, the total effectiveness of QMS for MS 9001 and MS ISO/ IEC 17025 is also determined via the number of conformance clause versus non-conformance clause for those three years. (author)

  2. Scaling of the Inertial Electrostatic Confinement (IEC) for near-term thrusters and future fusion propulsion

    International Nuclear Information System (INIS)

    Miley, G.; Bromley, B.; Jurczyk, B.; Stubbers, R.; DeMora, J.; Chacon, L.; Gu, Y.

    1998-01-01

    Inertial Electrostatic Confinement (IEC) is a unique approach to fusion and plasma energy systems that was conceptualized in the 1960s (Hirsch 1967) and has been the focus of recent development in the 1990s (Miley et al. 1995a). In the interests of space power and propulsion systems, conceptual rocket design studies (Bussard and Jameson 1994, Miley et al. 1995b) using the IEC have predicted excellent performance for a variety of space missions, since the power unit avoids the use of magnets and heavy drives resulting in a very high, specific impulse compared to other fusion systems. In their recent survey of prior conceptual design studies of fusion rockets, Williams and Borowski (1997) found that the Bussard IEC conceptual study (the open-quotes QEDclose quotes engine) offered a thrust-to-weight ratio of 10 milli-g close-quote s, a factor of five higher than conventional magnetic confinement concepts and even slightly above anti-proton micro fission/fusion designs. Thus there is considerable motivation to study IEC concepts for eventual space applications. However, the physics feasibility of the IEC still requires experimental demonstration, and an expanded data base is needed to insure that a power unit can in fact be built. copyright 1998 American Institute of Physics

  3. Increasing TRIGA fuel lifetime with 12 wt.% U TRIGA fuel

    Energy Technology Data Exchange (ETDEWEB)

    Naughton, W F; Cenko, M J; Levine, S H; Witzig, W F [Pennsylvania State University (United States)

    1974-07-01

    In-core fuel management studies have been performed for the Penn State Breazeale Reactor (PSBR) wherein 12 wt % U fuel elements are used to replace the standard 8.5 wt % U TRIGA fuel. The core configuration used to develop a calculational model was a 90-element hexagonal array, which is representative of the PSBR core, and consists of five hexagonal rings surrounding a central thimble containing water. The technique employed for refueling the core fully loaded with 8.5 wt % U fuel involves replacing 8.5 wt % U fuel with 12 wt % U fuel using an in-out reloading scheme. A batch reload consists of 6 new 12 wt % U fuel elements. Placing the 12 wt % U fuel in the B ring produces fuel temperatures ({approx}450 {sup o}C) that are well below the 800{sup o}C maximum limitation when the PSBR is operating at its maximum allowed power of 1 Megawatt. The advantages of using new 12 wt % U fuel to replace the burned up 8.5 wt % U fuel in the B ring over refueling strictly with 8.5 wt % U-Zr TRIGA fuel are clearly delineated in Table 1 where cost calculations used the General Atomic pre-1972 prices for TRIGA fuel, i.e., $1500 and $1650 for an 8.5 and 12 wt % U fuel element, respectively. Experimental results obtained to date utilizing the 12 wt % U fuel elements agree with the computed results. (author)

  4. Implementation of IEC Generic Models of Type 1 Wind Turbine Generator in DIgSILENT PowerFactory

    Institute of Scientific and Technical Information of China (English)

    Haoran ZHAO; Qiuwei WU; Ioannis MARGARIS; Poul S(O)RENSEN

    2013-01-01

    The implementation method for the International Electrotechnical Commission (IEC) generic models of Type 1 wind turbine generator (WTG) in DIgSILENT PowerFactory is presented.The following items are described,i.e.model structure,model blocks and how to implement these blocks in the PowerFactory environment.Case studies under both normal and fault conditions are done with the implemented IEC generic models of Type 1 WTG,and dynamic responses are captured and analyzed.The case study results show that the IEC generic models of Type 1 WTG can correctly represent the performances of Type 1 WTG under both normal and fault conditions.

  5. Measurement system for wind turbine acoustic noise assessment based on IEC standard and Qin′s model

    Institute of Scientific and Technical Information of China (English)

    Sun Lei; Qin Shuren; Bo Lin; Xu Liping; Stephan Joeckel

    2008-01-01

    A novel measurement system specially used in noise emission assessment and verification of wind turbine generator systems is presented that complies with specifications given in IEC 61400-11 to ensure the process consistency and accuracy. Theory elements of the calculation formula used for the sound power level of wind turbine have been discussed for the first time, and detailed calculation procedure of tonality and audibility integrating narrowband analysis and psychoacoustics is described. With a microphone and two PXI cards inserted into a PC, this system is designed in Qin′s model using VMIDS development system. Benefiting from the virtual instrument architecture, it′s the first time that all assessment process have been integrated into an organic whole, which gives full advantages of its efficiency, price, and facility. Mass experiments show that its assessment results accord with the ones given by MEASNET member.

  6. Standard Specification for Steel Blades Used with the Photovoltaic Module Surface Cut Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification specifies the recommended physical characteristics of the steel blades required for the surface cut test described in ANSI/UL 1703 (Section 24) and IEC 61730-2 (Paragraph 10.3). 1.2 ANSI/UL 1703 and IEC 61730-2 are standards for photovoltaic module safety testing. 1.3 This standard provides additional fabrication details for the surface cut test blades that are not provided in ANSI/UL 1703 or IEC 61730-2. Surface cut test blades that have out-of-tolerance corner radii or burrs are known to cause erroneous test results, either passes or failures. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. New conducted electrical weapons: Electrical safety relative to relevant standards.

    Science.gov (United States)

    Panescu, Dorin; Nerheim, Max; Kroll, Mark W; Brave, Michael A

    2017-07-01

    We have previously published about TASER ® conducted electrical weapons (CEW) compliance with international standards. CEWs deliver electrical pulses that can inhibit a person's neuromuscular control or temporarily incapacitate. An eXperimental Rotating-Field (XRF) waveform CEW and the X2 CEW are new 2-shot electrical weapon models designed to target a precise amount of delivered charge per pulse. They both can deploy 1 or 2 dart pairs, delivered by 2 separate cartridges. Additionally, the XRF controls delivery of incapacitating pulses over 4 field vectors, in a rotating sequence. As in our previous study, we were motivated by the need to understand the cardiac safety profile of these new CEWs. The goal of this paper is to analyze the nominal electrical outputs of TASER XRF and X2 CEWs in reference to provisions of all relevant international standards that specify safety requirements for electrical medical devices and electrical fences. Although these standards do not specifically mention CEWs, they are the closest electrical safety standards and hence give very relevant guidance. The outputs of several TASER XRF and X2 CEWs were measured under normal operating conditions. The measurements were compared against manufacturer specifications. CEWs electrical output parameters were reviewed against relevant safety requirements of UL 69, IEC 60335-2-76 Ed 2.1, IEC 60479-1, IEC 60479-2, AS/NZS 60479.1, AS/NZS 60479.2, IEC 60601-1 and BS EN 60601-1. Our study confirmed that the nominal electrical outputs of TASER XRF and X2 CEWs lie within safety bounds specified by relevant standards.

  8. Evaluation of a LiF:Mg,Ti thermoluminescent ring dosimeter according to the IEC 62387:2012 standards

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Edyelle L.B.; Barros, Vinícius S.M. de; Asfora, Viviane K.; Khoury, Helen J., E-mail: vsmdbarros@gmail.com [Unversidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear

    2017-07-01

    This work shows results of type testing of a ring dosimeter system under new IEC 62387:2012. The personal dosimeter investigated in this work consists of a commercial one element plastic ring (RADOS) which contains an LiF:Mg,Ti. By applying requirements for statistical fluctuations and linearity, a minimum measurable dose in Hp(0.07) was established. Energy and angular dependence aided in determining energy correction factors and fading requirements were used to select the most appropriate preheat scheme. Type testing of passive radiation monitors performed in the Radiation Metrology Laboratory (LMRI-DEN/UFPE) of the Federal University of Pernambuco is a major step in Brazil for the independent evaluation of these dosimeters, currently not available in the country. (author)

  9. ADAMS/WT advanced development - version 1.4 and beyond

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, A.S.; Depauw, T.R. [Mechanical Dynamics, Inc., Mesa, AZ (United States)

    1996-12-31

    ADAMS/WT is an wind-turbine-specific shell for the general-purpose mechanical system simulation package ADAMS5. It was developed under the guidance of the National Renewable Energy Laboratory to give engineers and analysts in the wind turbine community access to the analytical power of ADAMS, without having to become expert in its particular technology. The 1.4 version of ADAMS/WT is the most recent upgrade to the package, incorporating the most up-to-date version of the AeroDyn aerodynamic forcing subroutines from the University of Utah. It is also the first version to be made available on the Windows/NT platform. In version 1.4, ADAMS/WT has been significantly improved throughout and runs much faster. Automatic generation of standardized output has been added. The documentation has been extensively augmented with more detailed descriptions, more figures and more examples. ADAMS/WT remains the most powerful analytical tool available for horizontal-axis wind turbine development. 10 figs.

  10. Approaches to the ISO/IEC 17025 accreditation for Pu and U accountancy analysis

    International Nuclear Information System (INIS)

    Okazaki, Hiro; Sumi, Mika; Abe, Katsuo; Sato, Mitsuhiro; Kageyama, Tomio

    2013-01-01

    The quality control section of Plutonium Fuel Development Center (PFDC) of Japan Atomic Energy Agency has been analyzing isotopic compositions by Mass Spectrometry as well as content by Isotope Dilution Mass Spectrometry (IDMS) of plutonium and uranium in nuclear materials. Along with establishing and managing the quality assurance system, ensuring the reliability of the analysis data is important. PFDC has been establishing the quality management system with ISO9001. ISO9001 consists of management requirements for quality system of organizations. While ISO/IEC 17025 consists of technical requirements for the competence of testing and calibration laboratories in addition to the management requirements. The quality control section addressed technical improvement to improve further reliability of analysis quality and we have accredited for ISO/IEC 17025 of isotopic compositions and content of plutonium and uranium in nuclear materials in March 2010. In this presentation, we report our approaches to the ISO/IEC 17025 accreditation and operation status. (author)

  11. QA Programme of the TLD laboratory of the University of Costa Rica: IEC 61066 testing

    International Nuclear Information System (INIS)

    Mora, Patricia; Porras Chaverria, Mariela

    2008-01-01

    The Thermoluminescence Personal Dosimetry Laboratory of the University of Costa Rica provides dose measurements for around 90% of occupational radiation workers in the country. The assessment of doses to workers routinely exposed to external sources of radiation constitutes an integral part of any radiation protection programme and helps national authorities to ensure acceptably safe and satisfactory radiological conditions in workplaces. Harshaw Readers Model 4000 and 4500, dosimeter holders Type 8814 with TLD-100 in 0110 cards and loose TLD-100 chips are used to monitor personal dose equivalent, Hp(10) and Hp(0.07). In order to provide a reliable measurement of the operational quantities, a study was undertaken to verify the fulfillment of international requirements in our system (Model 4500 with cards) against the Thermoluminescence dosimetry systems for personal and environmental monitoring CEI IEC 61066 (1991 -2012). The type tests performed were nine in total: batch homogeneity, reproducibility, linearity, detection threshold, effect of climate conditions on reader, effect of light exposure on dosimeters, isotropy, transient voltage and dropping on dosimeters. A Cesium-137 source was used to irradiate the dosimeters and all procedures follow the indications given on the standard. Results showed that all IEC criteria were met by our Laboratory. Acceptable uncertainties were also studied under the ICRP recommendations; the analysis of the Trumpet Curve was done with satisfactory results (for doses above 0.5 mSv; quotient of measure to real dose less than 3%). For purposes of accreditation (ISO/IEC 17025:2005) and performance testing this work is very relevant since the University of Costa Rica wants to establish a solid individual monitoring programme for external radiation exposure that will provide users, registrants, licensees and regulatory bodies with information that can be used for the optimization of protection and dose limitation of Costa Rican workers

  12. Analysis of ISO/IEC 17025 for establishment of KOLAS (Korea Laboratory Accreditation Scheme) quality assurance system

    International Nuclear Information System (INIS)

    Nam, Ji Hee

    2000-12-01

    Besides one existent accredited lab, radioactive material chemical analysis lab, five test laboratories and two calibration labs are under plan to acquire the accreditation from KOLAS. But the current Quality Manual was developed according to ISO Guide 25 that was superceded by ISO/IEC 17025. Since it is tailored to the radioactive material chemical analysis lab, a number of requirements of the Manual are not applicable to the labs other than radioactive material chemical analysis lab. Through the analysis of ISO/IEC 17025, a model of quality system was established which is not only consistent with ISO/IEC 17025 but reflective of the KAERI's situation

  13. [Accreditation of clinical laboratories based on ISO standards].

    Science.gov (United States)

    Kawai, Tadashi

    2004-11-01

    International Organization for Standardization (ISO) have published two international standards (IS) to be used for accreditation of clinical laboratories; ISO/IEC 17025:1999 and ISO 15189:2003. Any laboratory accreditation body must satisfy the requirements stated in ISO/IEC Guide 58. In order to maintain the quality of the laboratory accreditation bodies worldwide, the International Laboratory Accreditation Cooperation (ILAC) has established the mutual recognition arrangement (MRA). In Japan, the International Accreditation Japan (IAJapan) and the Japan Accreditation Board for Conformity Assessment (JAB) are the members of the ILAC/MRA group. In 2003, the Japanese Committee for Clinical Laboratory Standards (JCCLS) and the JAB have established the Development Committee of Clinical Laboratory Accreditation Program (CLAP), in order to establish the CLAP, probably starting in 2005.

  14. Plan de implementación de un SGSI acorde a la norma ISO/IEC 27001:2005

    OpenAIRE

    Álvarez Verdugo, Joaquín

    2014-01-01

    Plan de implementación de un SGSI acorde a la norma ISO/IEC 27001:2005 en un organismo público municipal. Pla d'implementació d'un SGSI d'acord amb la norma ISO/IEC 27001:2005 en un organisme públic municipal. Master thesis for the ICT Security management program.

  15. HACIA LA EXTENSION DEL MÉTODO GRAY WATCH BASADO EN EL ESTÁNDAR DE CALIDAD ISO/IEC 25010 // TOWARDS THE EXTENSION OF THE GRAY WATCH METHOD BASED ON THE QUALITY STANDARD ISO/IEC 25010

    Directory of Open Access Journals (Sweden)

    Jorge Luis Pérez-Medina

    2012-06-01

    Full Text Available Talk about software quality implies the need to rely on parameters that should allow to establish the minimal levels that a product of this type must reach in order to be considered of quality. This paper aims to propose an extension of the method GRAY WATCH, specifically in the technical processes of Analysis and Design connecting the products obtained to the process of Implementation. The orientation of our proposal consists of using the standard of product quality ISO/IEC 25010, which establishes criteria for the specification of quality requirements of software products, their metrics and evaluation, and includes a quality model composed by characteristics and subcharacteristics. The result of this proposal, adds significant value to the extended method, Allowing to system analysts and Computer professionals to specify the precise activities to be performed to obtain quality requirements. To make this work we have supported our efforts in the Domain Engineering process based in Software Quality named InDoCaS as methodology for the definition of activities and products in the processes of Analysis, Design and Implementation of the Application.// RESUMEN: Hablar de calidad de software implica la necesidad de contar con parámetros que permitan establecer los niveles mínimos que un producto de este tipo debe alcanzar para que se considere de calidad. El presente articulo tiene como finalidad proponer una extension del método GRAY WATCH, especificamente en los procesos técnicos de análisis y diseño acoplando los productos obtenidos al proceso de implementación. La orientación de nuestra propuesta consiste en utilizar el estándar de calidad del producto ISO/IEC 25010, que establece criterios para la especificacion de requisitos de calidad de productos de software, sus métricas y su evaluación, e incluye un modelo de calidad compuesto por características y subcaracteristicas. El resultado de esta propuesta, agrega un valor importante al

  16. Wind Turbine Generator System Safety and Function Test Report for the Southwest Windpower H40 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    van Dam, J.; Link, H.; Meadors, M.; Bianchi, J.

    2002-06-01

    The objective of this test was to evaluate the safety and function characteristics of the Whisper H40 wind turbine. The general requirements of wind turbine safety and function tests are defined in the IEC standard WT01. The testing was conducted in accordance with the National Wind Technology Center (NWTC) Quality Assurance System, including the NWTC Certification Team Certification Quality Manual and the NWTC Certification Team General Quality Manual for the Testing of Wind Turbines, as well as subordinate documents. This safety and function test was performed as part of the U.S. Department of Energy's Field Verification Program for small wind turbines.

  17. DD fusion neutron production at UW-Madison using IEC devices

    Science.gov (United States)

    Fancher, Aaron; Michalak, Matt; Kulcinski, Gerald; Santarius, John; Bonomo, Richard

    2017-10-01

    An inertial electrostatic confinement (IEC) device using spherical, gridded electrodes at high voltage accelerates deuterium ions, allowing for neutrons to be produced within the device from DD fusion reactions. The effects of the device cathode voltage (30-170 kV), current (30-100 mA), and pressure (0.15-1.25 mTorr) on the neutron production rate have been measured. New high voltage capabilities have resulted in the achievement of a steady state neutron production rate of 3.3x108 n/s at 175 kV, 100 mA, and 1.0 mTorr of deuterium. Applications of IEC devices include the production of DD neutrons to detect chemical explosives and special nuclear materials using active interrogation methods. Research supported by US Dept. of Homeland Security Grant 2015-DN-077-AR1095 and the Grainger Foundation.

  18. Efficient IEC permanent-magnet motor (3 kW) - Final report; Effizienter IEC Permanent-Magnet-Motor (3 kW) - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M. [Circle Motor AG, Guemligen (Switzerland); Biner, H. P.; Evequoz, B. [Haute Ecole valaisanne, Sion (Switzerland); Salathe, D. [Hochschule Luzern, Technik und Architektur, Horw (Switzerland)

    2008-04-15

    Efficient permanent-magnet motors achieve in the area up to 100 kW a higher efficiency than induction machines (standard motors). A simple and fast energy saving option is the exchange of inefficient standard motors. The objective of this work is to install a 3 kW permanent-magnet motor in a standard IEC housing and the optimization of the design for high efficiency. Another objective is the development and the realization of an efficient variable speed control. The efficiency of the motor and the inverter with the control system must be demonstrated by tests. These tasks have been split between Circle Motor AG and the universities of applied sciences of Valais and Lucerne. Considering high-efficiency and low manufacturing cost, a brushless DC solution was adopted. This resulted in an optimum design of the motor and the control system realized with a three-phase rectifier, a buck converter with variable DC voltage, and a three-phase inverter feeding full positive and negative current to two of the legs simultaneously. The maximum measured efficiency is about 96.5% for the inverter and 92% for the motor. With the advantage of the variable speed operation, the efficiency of the realized 3 kW permanent magnet motor together with the control system is always higher than the efficiency of a measured class EFF1 induction motor, even with a direct connection to the grid. The permanent-magnet motor is also about 10 kg lighter. The cost calculation shows that the permanent-magnet motor can be competitive with the induction motor when speed control is desired. This is also the domain with the largest potential for energy savings from variable speed pumps, compressors, fans. (author)

  19. International standards for optical wireless communications: state-of-the-art and future directions

    Science.gov (United States)

    Marciniak, Marian

    2017-10-01

    As the number of active OWC installations is growing fast, the standards for compatibility of co-existing neighbouring systems are being developed. The paper addresses the Laser Safety (IEC standards), ITU-T Study Group 15 standards (G.640 Co-location longitudinally compatible interfaces for free space optical systems), ITU-Radiocommunication Sector standards (P.1817-1 Propagation data required for the design of terrestrial free-space optical links), and the IEEE Work in Progress - standardization activity on Visible Light Communications. International standards of FSO communications have been reviewed and discussed. ITU, IEC, and IEEE International standards for Free-Space Optical links have been reviewed. The system reliability and availability as well as security issues will be addressed as well in the talk.

  20. The spectra of the standard x-ray qualities used in STUK's Radiation Metrology Laboratory

    International Nuclear Information System (INIS)

    Tapiovaara, T.; Tapiovaara, M.; Siiskonen, T.; Hakanen, A.

    2008-02-01

    This report presents the fluence spectra of the standard x-radiation qualities used in the Radiation Dosimetry Laboratory of Radiation and Nuclear Safety Authority (STUK). The spectra were measured in August 2007. The radiation qualities characterised in the report are the ISO Narrow spectrum series (ISO N10-N200, ISO 4037-1:1996) and both of the RQR-spectrum series specified by the IEC (IEC 1267:1994 and IEC 61267:2005). The measurements were made using a high purity Ge-detector and the measured pulse height spectra were corrected to fluence spectra. Spectral characteristics were computed from the spectral data and compared to the requirements in the standards and to the values given in the quality manual of the laboratory. (orig.)

  1. ISO/IEC 17025: custos de acreditação em uma universidade pública brasileira

    Directory of Open Access Journals (Sweden)

    Rodrigo S. Bender

    2017-01-01

    Full Text Available ISO/IEC 17025 is an international standard that specifies the general requirements for evaluating the competence of laboratories involved in testing and calibration. This standard brings several benefits to university laboratories, which, thus, seek to obtain the accreditation. However, although cost is one of the main obstacles in this process; this topic has not been sufficiently studied. Since the Universidade Federal de Santa Maria (UFSM supports its laboratories for the implementation of this standard, it was chosen for this article to identify and quantify the accreditation costs of its laboratories that have obtained it or are working toward the goal. An exploratory literature review was carried out, and the data gathered were analyzed qualitatively and quantitatively. This study observed that the costs related to hours worked are linked to staff qualification and that high expenses in equipment and infrastructure occur in laboratories that receive financial resources from external providers.

  2. The Emerging JBIG2 Standard

    DEFF Research Database (Denmark)

    Howard, P.; Kossentini, F.; Martins, Bo

    1998-01-01

    The Joint Bi-level Image Experts Group (JBIG), an international study group affiliated with ISO/IEC and ITU-T, is in the process of drafting a new standard for lossy and lossless compression of bi-level images. The new standard, informally referred to as JBIG2, will support model-based coding...... with imperceptible loss of quality. It is expected that JBIG2 will become an International Standard by 2000....

  3. THE CHALLENGE OF CIEMAT INTERNAL DOSIMETRY SERVICE FOR ACCREDITATION ACCORDING TO ISO/IEC 17025 STANDARD, FOR IN VIVO AND IN VITRO MONITORING AND DOSE ASSESSMENT OF INTERNAL EXPOSURES.

    Science.gov (United States)

    Lopez, M A; Martin, R; Hernandez, C; Navarro, J F; Navarro, T; Perez, B; Sierra, I

    2016-09-01

    The accreditation of an Internal Dosimetry Service (IDS) according to ISO/IEC 17025 Standard is a challenge. The aim of this process is to guarantee the technical competence for the monitoring of radionuclides incorporated in the body and for the evaluation of the associated committed effective dose E(50). This publication describes the main accreditation issues addressed by CIEMAT IDS regarding all the procedures involving good practice in internal dosimetry, focussing in the difficulties to ensure the traceability in the whole process, the appropriate calculation of detection limit of measurement techniques, the validation of methods (monitoring and dose assessments), the description of all the uncertainty sources and the interpretation of monitoring data to evaluate the intake and the committed effective dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. IEC-TC88WG8 testing of rotor blades

    Energy Technology Data Exchange (ETDEWEB)

    Delft, D R.V. van [Delft Univ. of Technology, STEVIN Lab., Delft (Netherlands)

    1996-09-01

    In 1994 the TC88 of IEC installed a working group (WG8) to draft a guideline on blade testing. This paper gives a description of the task of the working group. Furthermore it gives a report of the progress of the work and summarizes the possible contents of the working group document on blade testing. (au)

  5. Proposal and Evaluation of Subordinate Standard Solar Irradiance Spectra for Applications in Solar Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jessen, Wilko [German Aerospace Center (DLR); Wilbert, Stefan [German Aerospace Center (DLR); Gueymard, Christian A. [Solar Consulting Services; Polo, Jesus [CIEMAT; Bian, Zeqiang [China Meteorological Administration; Driesse, Anton [Photovoltaic Performance Labs; Marzo, Aitor [University of Antofagasta; Armstrong, Peter [Masdar Institute of Science & Technology; Vignola, Frank [University of Oregon; Ramirez, Lourdes [CIEMAT

    2018-04-01

    Reference solar irradiance spectra are needed to specify key parameters of solar technologies such as photovoltaic cell efficiency, in a comparable way. The IEC 60904-3 and ASTM G173 standards present such spectra for Direct Normal Irradiance (DNI) and Global Tilted Irradiance (GTI) on a 37 degrees tilted sun-facing surface for one set of clear-sky conditions with an air mass of 1.5 and low aerosol content. The IEC/G173 standard spectra are the widely accepted references for these purposes. Hence, the authors support the future replacement of the outdated ISO 9845 spectra with the IEC spectra within the ongoing update of this ISO standard. The use of a single reference spectrum per component of irradiance is important for clarity when comparing and rating solar devices such as PV cells. However, at some locations the average spectra can differ strongly from those defined in the IEC/G173 standards due to widely different atmospheric conditions and collector tilt angles. Therefore, additional subordinate standard spectra for other atmospheric conditions and tilt angles are of interest for a rough comparison of product performance under representative field conditions, in addition to using the main standard spectrum for product certification under standard test conditions. This simplifies the product selection for solar power systems when a fully-detailed performance analysis is not feasible (e.g. small installations). Also, the effort for a detailed yield analyses can be reduced by decreasing the number of initial product options. After appropriate testing, this contribution suggests a number of additional spectra related to eight sets of atmospheric conditions and tilt angles that are currently considered within ASTM and ISO working groups. The additional spectra, called subordinate standard spectra, are motivated by significant spectral mismatches compared to the IEC/G173 spectra (up to 6.5%, for PV at 37 degrees tilt and 10-15% for CPV). These mismatches

  6. Convergence Analysis of ISO/IEC 12207 and CMMI-DEV: Complementary Result from Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Javier Crisóstomo

    2017-12-01

    Full Text Available The organizations and people are demanding more and better software products and services, which implies adequate processes for its development. In the context of the software industry, there are two models, the CMMI-DEV and ISO/IEC 12207 that are influencing it. Though, they are evolving separately, recurrently they have been compared to determine its coverage (in both directions. In this study is analyzed the results of those comparisons (partials and completed to determine if the models ISO/IEC 12207 and CMMI-DEV converge at processes level. This study identified eight articles where the comparison is carried out between ISO/IEC 12207 and CMMI-DEV. The results show that technique most used is the mapping comparisons between the models and according to the analyzed studies is not possible to determine whether there is convergence in the time. However, we found some items and criterions for use in comparisons.

  7. Review of international standards related to the design for control rooms on nuclear power plants

    International Nuclear Information System (INIS)

    Kitamura, Masashi; Yoshikawa, Hidekazu; Fujita, Yushi

    2005-01-01

    The improvement of Human-Machine Interface (HMI) design for control rooms on nuclear power plants (NPP) has been accomplished world wide, especially after the TMI-2 accident. The design process and guidelines are standardized in IEC60964 and supplemental standards as international standard. However, technological update is required due to the increased use of computerized control and monitoring equipment and systems in control rooms on NPP in recent years. Standards are becoming more important for computerized control rooms because there is more freedom to design than conventional hardware based system. For computerized control rooms, standards for hardware and software of HMI systems should be also considered. Standards and guidelines for computerized control rooms on NPP have been developed recently in each body such as IEC, ISO, and IEEE etc. Therefore, reviewing these standards and guidelines related to control rooms design of NPP can be useful not only for revision of the international standards such as IEC60964, but also for users of the standards and guidelines. In this paper, we reviewed the international standards related to the design for control rooms, in the two aspects of HMI design and hardware and software design, considering the undergoing revision work and their application. (author)

  8. Software Quality Assurance and Controls Standard

    Science.gov (United States)

    2010-04-27

    dassurance a wor pro uc s an processes comply with predefined provisions and plans. • According to International Standard (IS) 12207 – of the 44...from document (plan) focus to process focus – Alignment with framework standard IS 12207 software life cycle (SLC) processes with exact...Books and P blications IEEE Software and Systems Engineering curriculum ABET u Certified Software Development Professional Standards ISO /IEC

  9. Compliance of the CERN electronics used by the LHC Cryogenic System with the Electromagnetic Compatibility (EMC) Norm IEC 61000 4-4

    CERN Document Server

    Casas, J

    2011-01-01

    Within the ITER-CERN collaboration agreement, task “PROCUREMENT OF CRYOGENIC THERMOMETERS TO MONITOR ITER MAGNETS AND FEEDER TEMPERATURES”, CERN is recommending the use by ITER of LHC like electronics for the temperature channels. ITER require that any electronic equipment shall be qualified according to the standard IEC 61000 4-4 that refers to the Electromagnetic compatibility (EMC), Part 4: Testing and measurement techniques, Section 4: Electrical fast transient/burst immunity test (EFT/B). This document describes the qualification procedure and the results for the LHC like temperature measurement chains according to the procedures described in the standard.

  10. Study on a Threat-Countermeasure Model Based on International Standard Information

    Directory of Open Access Journals (Sweden)

    Guillermo Horacio Ramirez Caceres

    2008-12-01

    Full Text Available Many international standards exist in the field of IT security. This research is based on the ISO/IEC 15408, 15446, 19791, 13335 and 17799 standards. In this paper, we propose a knowledge base comprising a threat countermeasure model based on international standards for identifying and specifying threats which affect IT environments. In addition, the proposed knowledge base system aims at fusing similar security control policies and objectives in order to create effective security guidelines for specific IT environments. As a result, a knowledge base of security objectives was developed on the basis of the relationships inside the standards as well as the relationships between different standards. In addition, a web application was developed which displays details about the most common threats to information systems, and for each threat presents a set of related security control policies from different international standards, including ISO/IEC 27002.

  11. Using ISO/IEC 12207 to analyze open source software development processes: an E-learning case study

    OpenAIRE

    Krishnamurthy, Aarthy; O'Connor, Rory

    2013-01-01

    peer-reviewed To date, there is no comprehensive study of open source software development process (OSSDP) carried out for open source (OS) e-learning systems. This paper presents the work which objectively analyzes the open source software development (OSSD) practices carried out by e-learning systems development communities and their results are represented using DEMO models. These results are compared using ISO/IEC 12207:2008. The comparison of DEMO models with ISO/IEC...

  12. Increased IGF-IEc expression and mechano-growth factor production in intestinal muscle of fibrostenotic Crohn's disease and smooth muscle hypertrophy.

    Science.gov (United States)

    Li, Chao; Vu, Kent; Hazelgrove, Krystina; Kuemmerle, John F

    2015-12-01

    The igf1 gene is alternatively spliced as IGF-IEa and IGF-IEc variants in humans. In fibrostenotic Crohn's disease, the fibrogenic cytokine TGF-β1 induces IGF-IEa expression and IGF-I production in intestinal smooth muscle and results in muscle hyperplasia and collagen I production that contribute to stricture formation. Mechano-growth factor (MGF) derived from IGF-IEc induces skeletal and cardiac muscle hypertrophy following stress. We hypothesized that increased IGF-IEc expression and MGF production mediated smooth muscle hypertrophy also characteristic of fibrostenotic Crohn's disease. IGF-IEc transcripts and MGF protein were increased in muscle cells isolated from fibrostenotic intestine under regulation by endogenous TGF-β1. Erk5 and MEF2C were phosphorylated in vivo in fibrostenotic muscle; both were phosphorylated and colocalized to nucleus in response to synthetic MGF in vitro. Smooth muscle-specific protein expression of α-smooth muscle actin, γ-smooth muscle actin, and smoothelin was increased in affected intestine. Erk5 inhibition or MEF2C siRNA blocked smooth muscle-specific gene expression and hypertrophy induced by synthetic MGF. Conditioned media of cultured fibrostenotic muscle induced muscle hypertrophy that was inhibited by immunoneutralization of endogenous MGF or pro-IGF-IEc. The results indicate that TGF-β1-dependent IGF-IEc expression and MGF production in patients with fibrostenotic Crohn's disease regulates smooth muscle cell hypertrophy a critical factor that contributes to intestinal stricture formation. Copyright © 2015 the American Physiological Society.

  13. Selecting safety standards for nuclear power plants

    International Nuclear Information System (INIS)

    1981-01-01

    , and these relations are getting stronger. ISO work results in technical standards with emphasis on industrial and contractual aspects, and they deal with standardized procedures, designs, materials, test methods, and terminology. This complementary nature of IAEA and ISO standards, and the close co-operation between the two organizations have recently been formally recognized in a Memorandum of Understanding between the two organizations. The International Electrotechnical Commission (IEC) develops standards which are of the same character as those of ISO. In the nuclear field IEC standards apply to such items as reactor instrumentation and equipment for radiation monitoring. In these areas the IEC and the IAEA are co-operating to achieve harmony in related work and to avoid duplication. Great care is also taken in IEC work to take into account national standards of leading industrialized countries in order to avoid conflicting requirements in the IEC and the national electric standards. The programme of the Commission of the European Communities (CEC) was also described during the Seminar. The CEC priorities in nuclear safety are now related to the accident at Three Mile Island in the United States. Current activities include emergency planning and co-operation between neighbouring countries. Efforts are being made to establish agreed intervention levels. Operational safety also receives great attention. A European reliability centre is envisaged, the goal being to put a reliability system into pilot operation in 1983. In operator training greater emphasis is put on training for abnormal situations and on adapting simulator training for this purpose. Finally, efforts are made to establish a consistent approach among the CEC member states with regard to siting nuclear facilities

  14. Vertical Integration in factories using OPC-UA and IEC-61499

    Directory of Open Access Journals (Sweden)

    Marcelo V. García

    2017-02-01

    Full Text Available Nowadays, factory automation systems need to cope with very different challenges, such as big data, IIoT, etc. These challenges lead to a new generation of automation systems based on the so-called Cyber-Physical Production Systems (CPPS globally connected to form a flexible System of Cyber-Physical Production Systems (SoCPPS. CPPSs require acquisition of production system data and smart data processing to extract information to improve the overall system performance. To achieve that it is needed to bridge the gap between the control systems and higher layers. This paper discusses an approach to use the IEC 61499 function block concept to exchange data between plant floor and higher layers using an industrial standard like OPC UA. The OPC UA server offers subscription mechanisms, making possible the integration of several resources residing at plant floor. As it runs on embedded devices, the proposal makes possible to acquire plant information at low cost, enabling at the same time, a component-based design for enterprise plant floor control with independence of the hardware platform used

  15. 24 CFR 0.1 - Cross-reference to employees ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-04-01

    ... ethical conduct standards and financial disclosure regulations. 0.1 Section 0.1 Housing and Urban... Cross-reference to employees ethical conduct standards and financial disclosure regulations. Employees...-wide standards of ethical conduct at 5 CFR part 2635, the Department's regulation at 5 CFR part 7501...

  16. Calibration of kV measurers with the practical peak voltage (IEC 1676)

    International Nuclear Information System (INIS)

    Becker, Paulo H.B.; Peres, Marcos A.L.; Ludwig, Jaime L.; Chernicharo, Carlos C.

    2002-01-01

    The IEC 1676 standard introduces a new quantity for the measurements of the high voltages applied to the X ray tubes used for diagnosis, the 'Practical Peak Voltage' (PPV). In order to start the introduction of this new quantity in Brazil the National Laboratory for Metrology of Ionizing Radiation has developed a procedure for calibrating measuring instruments in this quantity. This procedure is based in the same set up used for the calibration of the conventional kVp, which consists in a high voltage divider (Dynalyser III from Radcal Corporation), a fast analogue to digital conversion board and a data acquisition software. In order to evaluate this procedure a commercial kVp measure instrument that is able to measure PPV (Universal Diavolt from PTW) was calibrated and the results compared. This work presents a summary of the procedure developed and the results obtained with the comparison. (author)

  17. Mechanical alloying and sitering of TI - 10WT.% MG powders

    CSIR Research Space (South Africa)

    Machio, Christopher N

    2009-06-01

    Full Text Available A Ti-10wt.%Mg powder alloy has been produced by mechanical alloying. Elemental powders of Ti and Mg were ball milled in a Zoz-Simoloyer CM01 for 16 and 20 hours under argon. Mechanical alloying was followed by XRD, SEM and particle size analysis...

  18. Availability of systems with self-diagnostic components--applying Markov model to IEC 61508-6

    International Nuclear Information System (INIS)

    Zhang Tieling; Long, Wei; Sato, Yoshinobu

    2003-01-01

    Of all the techniques applicable to safety-related analyses, each one may be adaptable to some aspects of the system safety behavior. On the other hand, some of them can fit to analysis on one aspect of the system behavior concerning risk, but they do not always lead to the same results. Rouvroye and Brombacher made a comparison of these techniques and indicated that Markov and Enhanced Markov analysis techniques can cover most aspects of system's safety-related behavior. According to their conclusion, the Markov method is introduced to Part 6 of the standard IEC 61508 for quantitative analysis in this paper. The purpose is to present explanation in details for solutions given in the standard because there are not clear descriptions for many results and it is not easy for a safety engineer to find the clue. In addition, the down time t c1 shown in the standard is newly defined because it is the basis to get the results of average probability of failure on demand of system architectures and its meaning is not clearly explained. Through derivation, however, a discrepancy is found in the standard. From this point of view, new suggestions are proposed based on the results obtained

  19. Effect of thermo-mechanical processing on microstructure and mechanical properties of U - Nb - Zr alloys: Part 2 - U - 3 wt % Nb - 9 wt % Zr and U - 9 wt% Nb - 3 wt% Zr

    Science.gov (United States)

    Morais, Nathanael Wagner Sales; Lopes, Denise Adorno; Schön, Cláudio Geraldo

    2018-04-01

    The present work is the second and final part of an extended investigation on Usbnd Nb - Zr alloys. It investigates the effect of mechanical processing routes on microstructure of alloys U - 3 wt % Nb - 9 wt % Zr and U - 9 wt% Nb - 3 wt% Zr, through X-ray diffraction and scanning electron microscopy, completing the investigation, which started with alloy U - 6 wt% Nb - 6 wt% Zr in part 1. Mechanical properties are determined using microhardness and bending tests and correlated with the developed microstructures. The results show that processing sequence, in particular the inclusion of a 1000 °C heat treatment step, affects significantly the microstructure and mechanical properties of these alloys alloy in different ways. Microstructural characterization shows that both alloys present significant volume fraction of precipitates of a body-centered cubic (BCC) γ-Nb-Zr rich phase in addition the uranium-rich matrix. Bending tests show that sample ductility does not correlate necessarily with hardness and that the key factor appears to be the amount of the γ-Nb-Zr precipitates, which controls the matrix microstructure. Samples with a monoclinic α″ cellular microstructure and/or with the tetragonally-distorted BCC phase (γ0), although not strictly ductile, showed the largest allowed strains-before-break and complete elastic recovery of the broken pieces, pointing out to the macroscopic observation of superelasticity.

  20. How ISO/IEC 17799 can be used for base lining information assurance among entities using data mining for defense, homeland security, commercial, and other civilian/commercial domains

    Science.gov (United States)

    Perry, William G.

    2006-04-01

    One goal of database mining is to draw unique and valid perspectives from multiple data sources. Insights that are fashioned from closely-held data stores are likely to possess a high degree of reliability. The degree of information assurance comes into question, however, when external databases are accessed, combined and analyzed to form new perspectives. ISO/IEC 17799, Information technology-Security techniques-Code of practice for information security management, can be used to establish a higher level of information assurance among disparate entities using data mining in the defense, homeland security, commercial and other civilian/commercial domains. Organizations that meet ISO/IEC information security standards have identified and assessed risks, threats and vulnerabilities and have taken significant proactive steps to meet their unique security requirements. The ISO standards address twelve domains: risk assessment and treatment, security policy, organization of information security, asset management, human resources security, physical and environmental security, communications and operations management, access control, information systems acquisition, development and maintenance, information security incident management and business continuity management and compliance. Analysts can be relatively confident that if organizations are ISO 17799 compliant, a high degree of information assurance is likely to be a characteristic of the data sets being used. The reverse may be true. Extracting, fusing and drawing conclusions based upon databases with a low degree of information assurance may be wrought with all of the hazards that come from knowingly using bad data to make decisions. Using ISO/IEC 17799 as a baseline for information assurance can help mitigate these risks.

  1. Maintaining and assessing extended 9 test methods in accordance with ISO/IEC 17025: 2005 for Isotopes Hydrology Laboratory

    International Nuclear Information System (INIS)

    Nguyen Thi Hong Thinh; Ha Lan Anh; Vo Thi Anh; Tran Khanh Minh; Vu Hoai

    2016-01-01

    The ISO/IEC 17025:2005 ''General requirements for the competence of testing and calibration laboratories'' is basis for the accreditation body of the country in general and VILAS in particular recognizing the competence of laboratories. With the desire to prove that we have sufficient technique and management capacity , and the ability to provide the legally recognized and technically valuable test results, the Isotope Hydrology Laboratory have developed and maintain a quality management system in accordance with ISO/IEC 17025:2005. In 2013, Isotope Hydrology Laboratory received a certificate of accreditation issued by Bureau of Accreditation which recognized the laboratory in accordance with ISO/IEC 17025:2005 with VILAS 670 accredited code. Scope of recognition is analyzed 14 parameters: F"-, Cl"-, NO_2"-, NO_3"-, Br"-, PO_4"3"-, SO_4"2"-, Li"+, Na"+, NH_4"+, K"+, Mg"2"+, Ca"2"+ and "3H in water by ion chromatography and liquid scintillator counting method. The laboratory has successfully implemented the task of maintaining quality management systems conform to ISO/IEC 17025: 2005 and expanded the scope of accreditation by 9 parameters in water: pH, EC, TSS, TDS, DO, BOD5, pH, Fe and Mn in 2015. (author)

  2. Implementation and Practical Benefits of ISO/IEC 17025:2005 in a ...

    African Journals Online (AJOL)

    User

    support of top management. ... quality management system, based on ISO/IEC 17025:2005, is achievable if there ... services of an accredited laboratory knowing that their decisions will be .... reports containing test results of the methods included in the Accreditation ..... As XYZ Laboratory is a water and wastewater testing.

  3. Implementing service quality based on ISO/IEC 20000 a management guide

    CERN Document Server

    Kunas, Michael

    2012-01-01

    Potential customers will look for suppliers with ISO/IEC 20000 certification, seeking the reassurance it provides. This book will guide you through implementation and certification. Your streamlined management processes will enable you to offer first-class customer service at competitive prices. The impact on your profit margins is clear!

  4. English translations of German standards. Catalogue 1988. 24. ed.

    International Nuclear Information System (INIS)

    1988-01-01

    The catalogue contains a list of all currently available English translations of DIN standards, and of English translations of DIN handbooks, a numerical index, an alphabetical index, and an index of DIN EN, DIN IEC, DIN ISO standards, LN and VG standards. Some useful information on standards work in Germany and on the activities of DIN Deutsches Institut fuer Normung e.V. is given. (orig./HP)

  5. A Method for Remote Control of EV Charging by Modifying IEC61851 Compliant EVSE Based PWM Signal

    DEFF Research Database (Denmark)

    Pedersen, Anders Bro; Martinenas, Sergejus; Andersen, Peter Bach

    2016-01-01

    The Electric Vehicle (EV) has properties that can not only load but can elevate its value as a resource to the power system. An EV represents a high-power, fast-responding flexible demand unit, with an attached energy storage (battery) and the potential for bi-directional capabilities (V2G......). These properties can be used in a number of power and energy services, which can support power system operation while lowering the cost of EV ownership. Such services depend on the support from the communications technologies and standards that connect controllers and logic in the EVs with those in the charging...... for smart charging - to gain this ability by simply adhering to the widely supported IEC61851 standard. This paper describes the solution, demonstrates the implementation and discusses the potential it has for unlocking EV power- and energy services....

  6. Effect of patchouli alcohol on the regulation of heat shock-induced oxidative stress in IEC-6 cells.

    Science.gov (United States)

    Liu, Xiaoxi; Jiang, Linshu; Liu, Fenghua; Chen, Yuping; Xu, Lei; Li, Deyin; Ma, Yunfei; Li, Huanrong; Xu, Jianqin

    2016-08-01

    Purpose Patchouli alcohol (PA) is used to treat gastrointestinal dysfunction. The purpose of this study was to ascertain the function of PA in the regulated process of oxidative stress in rat intestinal epithelial cells (IEC-6). Materials and methods Oxidative stress was stimulated by exposing IEC-6 cells to heat shock (42 °C for 3 h). IEC-6 cells in treatment groups were pretreated with various concentrations of PA (10, 40, and 80 ng/mL) for 3 h before heat shock. Results Heat shock caused damage to the morphology of IEC-6 cells, and increased reactive oxygen species (ROS) level and malondialdehyde (MDA) content. Moreover, mRNA and protein expression by target genes related to oxidative stress in heat shock were also altered. Specifically, the mRNA expression by HSP70, HSP90, GSH-px, NRF2 nd HO-1were all increased, and Nrf2 and Keap1 protein expression were increased after heat shock. However, pretreatment with PA weakened the level of damage to the cellular morphology, and decreased the MDA content caused by heat shock, indicating PA had cytoprotective activities. Pretreatment with PA at high dose significantly increased generation of intracellular ROS. Compared with the heat shock group alone, PA pretreatment significantly decreased the mRNA expression by HSP70, HSP90, SOD, CAT, GSH-px, KEAP1 and HO-1. Furthermore, the high dose of PA significantly increased Nrf2 protein expression, while both the intermediate and high dose of PA significantly increased HO-1 protein expression. Conclusion Heat-shock-induced oxidative stress in IEC-6 cells, and PA could alleviate the Nrf2-Keap1 cellular oxidative stress responses.

  7. Optimal Selective Harmonic Mitigation Technique on Variable DC Link Cascaded H-Bridge Converter to Meet Power Quality Standards

    DEFF Research Database (Denmark)

    Najjar, Mohammad; Moeini, Amirhossein; Dowlatabadi, Mohammadkazem Bakhshizadeh

    2016-01-01

    In this paper, the power quality standards such as IEC 61000-3-6, IEC 61000-2-12, EN 50160, and CIGRE WG 36-05 are fulfilled for single- and three-phase medium voltage applications by using Selective Harmonic Mitigation-PWM (SHM-PWM) in a Cascaded H-Bridge (CHB) converter. Furthermore, the ER G5/...

  8. Importance of international standards on hydrogen technologies

    International Nuclear Information System (INIS)

    Bose, T.K.; Gingras, S.

    2001-01-01

    This presentation provided some basic information regarding standards and the International Organization for Standardization (ISO). It also explained the importance of standardization activities, particularly ISO/TC 197 which applies to hydrogen technologies. Standards are established by consensus. They define the minimum requirements that will ensure that products and services are reliable and effective. Standards contribute to the elimination of technical barriers to trade (TBT). The harmonization of standards around the world is desirable in a free trade environment. The influence of the TBT on international standardization was discussed with particular reference to the objectives of ISO/TC 197 hydrogen technologies. One of the priorities for ISO/TC 197 is a hydrogen fuel infrastructure which includes refuelling stations, fuelling connectors, and storage technologies for gaseous and liquid hydrogen. Other priorities include an agreement between the International Electrotechnical Commission (IEC) and the ISO, in particular the IEC/TC 105 and ISO/TC 197 for the development of fuel cell standards. The international standards that have been published thus far include ISO 13984:1999 for liquid hydrogen, land vehicle fuelling system interface, and ISO 14687:1999 for hydrogen fuel product specification. Standards are currently under development for: liquid hydrogen; airport hydrogen fuelling facilities; gaseous hydrogen blends; basic considerations for the safety of hydrogen systems; gaseous hydrogen and hydrogen blends; and gaseous hydrogen for land vehicle filling connectors. It was concluded that the widespread use of hydrogen is dependent on international standardization

  9. Effects of W on microstructure of as-cast 28 wt.%Cr–2.6 wt.%C–(0–10)wt.%W irons

    Energy Technology Data Exchange (ETDEWEB)

    Imurai, S. [Department of Physics and Materials Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thanachayanont, C.; Pearce, J.T.H. [National Metal and Materials Technology Center, Pathumthani 12120 (Thailand); Tsuda, K. [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Chairuangsri, T., E-mail: tchairuangsri@gmail.com [Department of Industrial Chemistry, Chiang Mai University, Chiang Mai 50200 (Thailand)

    2015-01-15

    Microstructures of as-cast 28 wt.%Cr–2.6 wt.%C irons containing (0–10)wt.%W with the Cr/C ratio about 10 were studied and related to their hardness. The experimental irons were cast into dry sand molds. Microstructural investigation was performed by light microscopy, X-ray diffractometry, scanning electron microscopy, transmission electron microscopy and energy-dispersive X-ray spectrometry. It was found that the irons with 1 to 10 wt.%W addition was hypereutectic containing large primary M{sub 7}C{sub 3}, whereas the reference iron without W addition was hypoeutectic. The matrix in all irons was austenite, partly transformed to martensite during cooling. The volume fractions of primary M{sub 7}C{sub 3} and the total carbides increased, but that of eutectic carbides decreased with increasing the W content of the irons. W addition promoted the formation of W-rich M{sub 7}C{sub 3}, M{sub 6}C and M{sub 23}C{sub 6}. At about 4 wt.%W, two eutectic carbides including M{sub 7}C{sub 3} and M{sub 6}C were observed together with primary M{sub 7}C{sub 3}. At 10 wt.%W, multiple carbides including primary M{sub 7}C{sub 3}, fish-bone M{sub 23}C{sub 6}, and M{sub 6}C were observed. M{sub x}C where x = 3 or less has not been found due possibly to the high M/C ratio in the studied irons. W distribution to all carbides has been determined increasing from ca. 0.3 to 0.8 in mass fraction as the W content in the irons was increased. W addition led to an increase in Vickers macro-hardness of the irons up to 671 kgf/(mm){sup 2} (HV30/15) obtained from the iron with 10 wt.%W. The formation of primary M{sub 7}C{sub 3} and aggregates of M{sub 6}C and M{sub 23}C{sub 6} were the main reasons for hardness increase, indicating potentially improved wear performance of the as-cast irons with W addition. - Highlights: • W addition at 1 up to 10 wt.%W to Fe–28Cr–2.6C produced “hypereutectic” structure. • W addition promoted the formation of W-rich M{sub 7}C{sub 3}, M{sub 6}C and M

  10. A fully automated system for ultrasonic power measurement and simulation accordingly to IEC 61161:2006

    International Nuclear Information System (INIS)

    Costa-Felix, Rodrigo P B; Alvarenga, Andre V; Hekkenberg, Rob

    2011-01-01

    The ultrasonic power measurement, worldwide accepted, standard is the IEC 61161, presently in its 2nd edition (2006), but under review. To fulfil its requirements, considering that a radiation force balance is to be used as ultrasonic power detector, a large amount of raw data (mass measurement) shall be collected as function of time to perform all necessary calculations and corrections. Uncertainty determination demands calculation effort of raw and processed data. Although it is possible to be undertaken in an old-fashion way, using spread sheets and manual data collection, automation software are often used in metrology to provide a virtually error free environment concerning data acquisition and repetitive calculations and corrections. Considering that, a fully automate ultrasonic power measurement system was developed and comprehensively tested. A 0,1 mg of precision balance model CP224S (Sartorius, Germany) was used as measuring device and a calibrated continuous wave ultrasound check source (Precision Acoustics, UK) was the device under test. A 150 ml container filled with degassed water and containing an absorbing target at the bottom was placed on the balance pan. Besides the feature of automation software, a routine of power measurement simulation was implemented. It was idealized as a teaching tool of how ultrasonic power emission behaviour is with a radiation force balance equipped with an absorbing target. Automation software was considered as an effective tool for speeding up ultrasonic power measurement, while allowing accurate calculation and attractive graphical partial and final results.

  11. Analisis Sistem Manajemen Keamanan Informasi Menggunakan ISO/IEC 27001 : 2013 Serta Rekomendasi Model Sistem Menggunakan Data Flow Diagram pada Direktorat Sistem Informasi Perguruan Tinggi

    Directory of Open Access Journals (Sweden)

    Yuni Cintia Yuze

    2016-11-01

    Full Text Available The importance of information and the possible risk of disruption, therefore the universities need to designed and implemented of the information security.  One of the standards that can be used to analyze the level of information security in the organization is ISO/IEC 27001 : 2013 and this standard has been prepared to provide requirements for establishing, implementing, maintaining and continually improving an information security management system. The objective of this research is to measure the level of information security based on standard ISO/IEC 27001: 2013 and modeling systems for information security management. This research uses descriptive qualitative approach, data collection and validation techniques with tringulasi (interview, observation and documentation. Data was analyzed using gap analysis and to measure the level of maturity this research uses SSE-CMM (Systems Security Engineering Capability Maturity Model. Based on the research results, Maturity level clause Information Security Policy reaches level 1 (Performed-Informally, clause Asset Management reaches level 3 (Well-Defined, clause Access Control reaches level 3 (Well-Defined, clause Physical and Environmental Security reaches level 3 (Well-Defined, clause Operational Security reaches level 3 (Well-Defined, Communication Security clause reaches the level 2 (Planned and Tracked. Based on the results of maturity level discovery of some weakness in asset management in implementing the policy. Therefore, the modeling system using the flow map and CD / DFD focused on Asset Management System.

  12. Mobile measurement setup according to IEC 62220-1-2 for DQE determination on digital mammography systems

    Science.gov (United States)

    Greiter, Matthias B.; Hoeschen, Christoph

    2010-04-01

    The international standard IEC 62220-1-2 defines the measurement procedure for determination of the detective quantum efficiency (DQE) of digital x-ray imaging devices used in mammography. A mobile setup complying to this standard and adaptable to most current systems was constructed in the Helmholtz Zentrum München to allow for an objective technical comparison of current full field digital mammography units employed in mammography screening in Germany. This article demonstrates the setup's capabilities with a focus on the measurement uncertainties of all quantities contributing to DQE measurements. Evaluation of uncertainties encompasses results from measurements on a Sectra Microdose Mammography in clinical use, as well as on a prototype of a Fujifilm Amulet system at various radiation qualities. Both systems have a high spatial resolution of 50 μm × 50 μm. The modulation transfer function (MTF), noise power spectrum (NPS) and DQE of the Sectra MDM are presented in comparison to results previously published by other authors.

  13. Analysis list: Wt1 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Wt1 Embryo,Kidney + mm9 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Wt1.1....tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Wt1.5.tsv http://dbarchive.biosciencedbc.jp/kyush...u-u/mm9/target/Wt1.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Wt1.Embryo.tsv,http://dbarchive.bioscience...dbc.jp/kyushu-u/mm9/colo/Wt1.Kidney.tsv http://dbarchive.biosciencedb...c.jp/kyushu-u/mm9/colo/Embryo.gml,http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Kidney.gml ...

  14. WT1 vaccination in acute myeloid leukemia: new methods of implementing adoptive immunotherapy.

    Science.gov (United States)

    Rein, Lindsay A M; Chao, Nelson J

    2014-03-01

    The Wilms tumor 1 (WT1) gene was originally identified as a tumor suppressor gene that, when mutated, would lead to the development of pediatric renal tumors. More recently, it has been determined that WT1 is overexpressed in 90% of patients with acute myeloid leukemia (AML) and is mutated in approximately 10% of AML patients. WT1 plays a role in normal hematopoiesis and, in AML specifically, it has oncogenic function and plays an important role in cellular proliferation and differentiation. The ubiquity of WT1 in leukemia has lead to the development of vaccines aimed at employing the host immune system to mount a T-cell response to a known antigen. In this evaluation, the authors discuss the role of WT1 in normal hematopoiesis as well as in the development of hematologic malignancies. Furthermore, the authors discuss the data supporting the development of WT1 vaccines, and the clinical trials supporting their use in patients with acute leukemia. Several small trials have been conducted which support the safety and efficacy of this therapy, although larger trials are certainly warranted. In the authors' opinion, the WT1 vaccination has potential in terms of its application as an adjuvant therapy for patients with AML who are at high risk of relapse or who have detectable minimal residual disease after initial standard therapy.

  15. Viscous behavior of (Sn61.9Pb38.1)100-xREx (x=0, 0.1, 0.3, 1 wt%) solder alloys

    International Nuclear Information System (INIS)

    Wu Yuqin; Bian Xiufang; Zhao Yan; Li Xuelian; Zhang Yanning; Tian Yongsheng; Lv Xiaoqian

    2008-01-01

    The viscous behavior of (Sn 61.9 Pb 38.1 ) 100-x RE x (x=0, 0.1, 0.3, 1 wt%) solder alloys has been investigated by a torsional oscillation viscometer. The structural transition temperature T ' increases with increasing addition of RE elements. Above T ' , the viscosities of melts increase with increasing addition of RE, and are fitted well with the Arrhenius equation. The time dependence of viscosity at the measured temperature below T ' follows the exponential relaxation function and reflects the process of the structural transition in the melt, which can be considered as the thermodynamic equilibrium process. The thermodynamic equilibrium relaxation time τ eq increases with both the equilibrium viscosity η eq and the discrepancy in viscosity (Δη), between the initial state and the equilibrium state. However, it decreases with the measured temperature T. The size of clusters in the melts increases with increasing of viscosity and is restricted by the thermodynamic equilibrium conditions

  16. Effects of concomitant temozolomide and radiation therapies on WT1-specific T-cells in malignant glioma

    International Nuclear Information System (INIS)

    Chiba, Yasuyoshi; Hashimoto, Naoya; Tsuboi, Akihiro

    2010-01-01

    Immunotherapy targeting the Wilms' tumour 1 gene product has been proven safe and effective for treating malignant glioma in a phase II clinical study. Currently, radiation/temozolomide therapy is the standard treatment with only modest benefit. Whether combining radiation/temozolomide therapy with WT1 immunotherapy will have a negating effect on immunotherapy is still controversial because of the significant lymphocytopaenia induced by the former therapy. To address this issue, we investigated the changes in frequency and number of WT1-specific T-cells in patients with malignant gliomas. Twenty-two patients with newly diagnosed malignant glioma who received standard radiation/temozolomide therapy were recruited for the study. Blood samples were collected before treatment and on the sixth week of therapy. The frequencies and numbers of lymphocytes, CD8 + T-cells, WT1-specific T-cells, regulatory T-cells, natural killer cells and natural killer T-cells were measured and analysed using T-tests. Analysis of the frequency of T lymphocytes and its subpopulation showed an increase in regulatory T-cells, but no significant change was noted in the populations of T-cells, WT1-specific T-cells, natural killer (NK) cells and natural killer T (NKT) cells. Reductions in the total numbers of T-cells, WT1-specific T-cells, NK cells and NKT cells were mainly a consequence of the decrease in the total lymphocyte count. Radiation/temozolomide therapy did not significantly affect the frequency of WT1-specific T-cells, suggesting that the combination with WT1 immunotherapy may be possible, although further assessment in the clinical setting is warranted. (author)

  17. Effects of Mo on microstructure of as-cast 28 wt.% Cr–2.6 wt.% C–(0–10) wt.% Mo irons

    Energy Technology Data Exchange (ETDEWEB)

    Imurai, S. [Department of Physics and Materials Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thanachayanont, C.; Pearce, J.T.H. [National Metal and Materials Technology Center, Pathumthani 12120 (Thailand); Tsuda, K. [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Chairuangsri, T., E-mail: tchairuangsri@gmail.com [Department of Industrial Chemistry, Chiang Mai University, Chiang Mai 50200 (Thailand)

    2014-04-01

    Microstructures of as-cast 28 wt.% Cr–2.6 wt.% C irons containing (0–10) wt.% Mo with the Cr/C ratio of about 10 were studied and related to hardness. The experimental irons were cast into dry sand molds. Microstructural investigation was performed by light microscopy, X-ray diffractometry, scanning electron microscopy, transmission electron microscopy and energy-dispersive X-ray spectrometry. It was found that the iron with about 10 wt.% Mo was eutectic/peritectic, whereas the others with less Mo content were hypoeutectic. The matrix in all irons was austenite, partly transformed to martensite during cooling. Mo addition promoted the formation of M{sub 23}C{sub 6} and M{sub 6}C. At 1 wt.% Mo, multiple eutectic carbides including M{sub 7}C{sub 3}, M{sub 23}C{sub 6} and M{sub 6}C were observed. M{sub 23}C{sub 6} existed as a transition zone between eutectic M{sub 7}C{sub 3} and M{sub 6}C, indicating a carbide transition as M{sub 7}C{sub 3}(M{sub 2.3}C) → M{sub 23}C{sub 6}(M{sub 3.8}C) → M{sub 6}C. At 6 wt.% Mo, multiple eutectic carbides including M{sub 7}C{sub 3} and M{sub 23}C{sub 6} were observed together with fine cellular/lamellar M{sub 6}C aggregates. In the iron with 10 wt.% Mo, only eutectic/peritectic M{sub 23}C{sub 6} and M{sub 6}C were found without M{sub 7}C{sub 3}. Mo distribution to all carbides has been determined to be increased from ca. 0.4 to 0.7 in mass fraction as the Mo content in the irons was increased. On the other hand, Cr distribution to all carbides is quite constant as ca. 0.6 in mass fraction. Mo addition increased Vickers macro-hardness of the irons from 495 up to 674 HV{sub 30}. High Mo content as solid-solution in the matrix and the formation of M{sub 6}C or M{sub 23}C{sub 6} aggregates were the main reasons for hardness increase, indicating potentially improved wear performance of the irons with Mo addition. - Highlights: • Mo promoted the formation of M{sub 23}C{sub 6} and M{sub 6}C in the irons with Cr/C ratio of about 10

  18. Standardization in smart grids. Introduction to IT-related methodologies, architectures and standards

    Energy Technology Data Exchange (ETDEWEB)

    Uslar, Mathias; Specht, Michael; Daenekas, Christian; Trefke, Joern; Rohjans, Sebastian; Gonzalez, Jose M.; Rosinger, Christine; Bleiker, Robert [OFFIS - Institut fuer Informatik, Oldenburg (Germany)

    2013-03-01

    Introduction to Standardization for Smart Grids. Presents a tutorial and best practice of Smart Grid Prototype Projects. Written by leading experts in the field. Besides the regulatory and market aspects, the technical level dealing with the knowledge from multiple disciplines and the aspects of technical system integration to achieve interoperability and integration has been a strong focus in the Smart Grid. This topic is typically covered by the means of using (technical) standards for processes, data models, functions and communication links. Standardization is a key issue for Smart Grids due to the involvement of many different sectors along the value chain from the generation to the appliances. The scope of Smart Grid is broad, therefore, the standards landscape is unfortunately very large and complex. This is why the three European Standards Organizations ETSI, CEN and CENELEC created a so called Joint Working Group (JWG). This was the first harmonized effort in Europe to bring together the needed disciplines and experts delivering the final report in May 2011. After this approach proved useful, the Commission used the Mandate M/490: Standardization Mandate to European Standardization Organizations (ESOs) to support European Smart Grid deployment. The focal point addressing the ESO's response to M/490 will be the CEN, CENELEC and ETSI Smart Grids Coordination Group (SG-CG). Based on this mandate, meaningful standardization of architectures, use cases, communication technologies, data models and security standards takes place in the four existing working groups. This book provides an overview on the various building blocks and standards identified as the most prominent ones by the JWG report as well as by the first set of standards group - IEC 61850 and CIM, IEC PAS 62559 for documenting Smart Grid use cases, security requirements from the SGIS groups and an introduction on how to apply the Smart Grid Architecture Model SGAM for utilities. In addition

  19. Implementation of draft IEC Generic Model of Type 1 Wind Turbine Generator in PowerFactory and Simulink

    DEFF Research Database (Denmark)

    Zhao, Haoran; Wu, Qiuwei; Sørensen, Poul Ejnar

    2013-01-01

    This paper presents the implementation work of IEC generic model of Type 1 wind turbine generator (WTG) in two commercial simulation tools: DIgSILENT PowerFactory (PF) and Matlab Simulink. The model topology, details of the composite blocks and implementation procedure in PF and Simulink environm......This paper presents the implementation work of IEC generic model of Type 1 wind turbine generator (WTG) in two commercial simulation tools: DIgSILENT PowerFactory (PF) and Matlab Simulink. The model topology, details of the composite blocks and implementation procedure in PF and Simulink...

  20. Air kerma standardization for diagnostic radiology, and requirements proposal for calibration laboratories

    International Nuclear Information System (INIS)

    Ramos, Manoel Mattos Oliveira

    2009-01-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. A metrology network was created, but it is not yet accredited by the accreditation organism of the country, INMETRO. The objective of this work was to implement the standardization of the air kerma for the un attenuated qualities (RQR) of IEC 61267, and to develop a requirement proposal for instruments calibration laboratories. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. A laboratory requirement proposal was finalized and it shall be submitted to INMETRO to be used as auxiliary normative document in laboratory accreditation. (author)

  1. Protective effects of essential oil of Citrus limon against aspirin-induced toxicity in IEC-6 cells.

    Science.gov (United States)

    Bouzenna, Hafsia; Hfaiedh, Najla; Giroux-Metges, Marie-Agnès; Elfeki, Abdelfattah; Talarmin, Hélène

    2017-05-01

    Aspirin, one of the widely used nonsteroidal anti-inflammatory drugs, is the most highly consumed pharmaceutical product in the world. However, it has several side effects in cells. This study was designed to investigate the antioxidative activity and cytoprotective effects of essential oil of Citrus limon (EOC) extracted from leaves against aspirin-induced damages in the rat small intestine epithelial cells (IEC-6). Biochemical indicators were used to assess cytotoxicity and oxidative damages caused by aspirin treatment on IEC-6. Our results showed that the chemical characterization of EOC identified 25 compounds representing 98.19% of the total oil. The major compounds from this oil were z-citral (53.21%), neryl acetate (13.06%), geranyl acetate (10.33%), and limonene (4.23%). Aspirin induced a decrease in cell viability as well as an increase in superoxide dismutase (SOD) and catalase (CAT) activities. Contrariwise, the co-exposure of cells to aspirin and EOC alleviated every above syndrome by an increase in cell survival and decrease in SOD and CAT activities. In conclusion, the essential oil of C. limon has a potent cytoprotective effect against aspirin-induced toxicity in IEC-6 cells.

  2. Effect of graphenenano-platelets on the mechanical properties of Mg/3wt%Al alloy-nanocomposite

    Science.gov (United States)

    Kumar, Pravir; Kujur, MilliSuchita; Mallick, Ashis; Sandar Tun, Khin; Gupta, Manoj

    2018-04-01

    The bulk Mg/3%Al/0.1%GNP alloy-nano composite was fabricated using powder metallurgy route assisted with microwave sintering and followed by hot extrusion. The microstructural and Raman spectroscopy studies were performed to characterize the graphene nano-platelet(GNP).EDX tests confirmed the presence and the homogeneous distribution of Al and graphene nano-platelets in the magnesium alloy-nanocomposite. The addition of 3 wt% Al and 0.1wt%GNP to the Mg changed Vicker hardness, ultimate tensile strength and failure strain by +46.15%,+17.6% and -5% respectively. The fabricated composite offers higher resistance to the local deformation than monolithic Mg and Mg/3%Al alloy, revealed by the load/unload-indentation depth curve.

  3. Automation of an energy-autarkic manufacturing plant following IEC 61499; Automatisierung einer energieautarken Fertigungsanlage nach IEC 61499

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, Christian; Hirsch, Martin; Hanisch, Hans-Michael [Halle-Wittenberg Univ., Halle (Saale) (Germany). Lehrstuhl Automatisierungstechnik

    2009-07-01

    The requirements for future manufacturing plants are, beyond others, seamless reconfiguration, autonomy as far as possible as well as easy employment and maintenance for the end user. Within the EnAS project (Energy-Autarkic Actuators and Sensors), the group of the Automation Technology Lab in Halle has challenged the fulfillment of those requirements. Therefore, IEC 61499 compliant distributed controllers have been developed for the demonstrator-plant under particular consideration of reconfigurability. These controllers have been integrated into the process sequences of the demonstrator and afterwards several reconfiguration scenarios have been designed. The building of a Human-Machine-Interface for visualization and reconfiguration of the plant was an essential issue as well. The result is a highly flexible, easily reconfigurable system, which can be regarded as a prototype for automated manufacturing plants of a new generation. (orig.)

  4. Secondary standard dosimetry laboratory at INFLPR

    Energy Technology Data Exchange (ETDEWEB)

    Scarlat, F.; Minea, R.; Scarisoreanu, A.; Badita, E.; Sima, E.; Dumitrascu, M.; Stancu, E.; Vancea, C., E-mail: scarlat.f@gmail.com [National Institute for Laser, Plasma and Radiation Physics - INFLPR, Bucharest (Romania)

    2011-07-01

    National Institute for Laser, Plasma and Radiation Physics (INFLPR) has constructed a High Energy Secondary Standard Dosimetry Laboratory SSDL-STARDOOR - for performing dosimetric calibrations according to ISO IEC SR/EN 17025:2005 standards. This is outfitted with UNIDOS Secondary Standard Dosimeter from PTW (Freiburg Physikalisch-Technische Werksttaten) calibrated at the PTB-Braunschweig (German Federal Institute of Physics and Metrology). A radiation beam of the quality of Q used by our laboratory as calibration source are provided by INFLPR 7 MeV electron beam linear accelerator mounted in our facility. (author)

  5. Model-driven design using IEC 61499 a synchronous approach for embedded and automation systems

    CERN Document Server

    Yoong, Li Hsien; Bhatti, Zeeshan E; Kuo, Matthew M Y

    2015-01-01

    This book describes a novel approach for the design of embedded systems and industrial automation systems, using a unified model-driven approach that is applicable in both domains.  The authors illustrate their methodology, using the IEC 61499 standard as the main vehicle for specification, verification, static timing analysis and automated code synthesis.  The well-known synchronous approach is used as the main vehicle for defining an unambiguous semantics that ensures determinism and deadlock freedom. The proposed approach also ensures very efficient implementations either on small-scale embedded devices or on industry-scale programmable automation controllers (PACs). It can be used for both centralized and distributed implementations. Significantly, the proposed approach can be used without the need for any run-time support. This approach, for the first time, blurs the gap between embedded systems and automation systems and can be applied in wide-ranging applications in automotive, robotics, and industri...

  6. Análisis de la norma ISO/IEC 27001 : Diseño de implementación en la red de una empresa.

    OpenAIRE

    Sandoval Vargas, César Andrés

    2014-01-01

    Durante el proceso de esta investigación se aborda el tema relacionado con la seguridad informática, haciendo énfasis en el análisis de la norma ISO/IEC (International Organization for Standardization / International Electrotechnical Commission) 27001 y su puesta en práctica en una empresa o institución. El trabajo se encuentra dividido en tres capítulos. En el primero se efectúa un estudio de la seguridad informática.- Durante el segundo capítulo se lleva a cabo una caracterización general ...

  7. Loss of guanylyl cyclase C (GCC signaling leads to dysfunctional intestinal barrier.

    Directory of Open Access Journals (Sweden)

    Xiaonan Han

    2011-01-01

    Full Text Available Guanylyl Cyclase C (GCC signaling via uroguanylin (UGN and guanylin activation is a critical mediator of intestinal fluid homeostasis, intestinal cell proliferation/apoptosis, and tumorigenesis. As a mechanism for some of these effects, we hypothesized that GCC signaling mediates regulation of intestinal barrier function.Paracellular permeability of intestinal segments was assessed in wild type (WT and GCC deficient (GCC-/- mice with and without lipopolysaccharide (LPS challenge, as well as in UGN deficient (UGN-/- mice. IFNγ and myosin light chain kinase (MLCK levels were determined by real time PCR. Expression of tight junction proteins (TJPs, phosphorylation of myosin II regulatory light chain (MLC, and STAT1 activation were examined in intestinal epithelial cells (IECs and intestinal mucosa. The permeability of Caco-2 and HT-29 IEC monolayers, grown on Transwell filters was determined in the absence and presence of GCC RNA interference (RNAi. We found that intestinal permeability was increased in GCC-/- and UGN-/- mice compared to WT, accompanied by increased IFNγ levels, MLCK and STAT1 activation in IECs. LPS challenge promotes greater IFNγ and STAT1 activation in IECs of GCC-/- mice compared to WT mice. Claudin-2 and JAM-A expression were reduced in GCC deficient intestine; the level of phosphorylated MLC in IECs was significantly increased in GCC-/- and UGN-/- mice compared to WT. GCC knockdown induced MLC phosphorylation, increased permeability in IEC monolayers under basal conditions, and enhanced TNFα and IFNγ-induced monolayer hyperpermeability.GCC signaling plays a protective role in the integrity of the intestinal mucosal barrier by regulating MLCK activation and TJ disassembly. GCC signaling activation may therefore represent a novel mechanism in maintaining the small bowel barrier in response to injury.

  8. Analysis of Norm IEC 61850 in the transmission of data via communications network of substations

    Energy Technology Data Exchange (ETDEWEB)

    Renda, T.; Botura Junior, G. [Universidade Estadual Paulista (UNESP), Sorocaba, SP (Brazil); Mesquita, L.; Rizol, P.M.S.R. [Universidade Estadual Paulista (UNESP), Guaratingueta, SP (Brazil)

    2009-07-01

    The tendency of using a protocol allows electrical substations to become 'intelligent', that is, capable of communicating in a much more efficient manner. This greatly reduces the number of connections, and as a consequence optimizes the speed between messages. The Norm IEC 61850-9-2 came to minimize the use of cables for the interconnections of various equipment involved in safety procedures of a substation. The present paper, has the objective of identifying a way of integrating the Norm IEC-61850 with the transmission of data via 'Generic Object Oriented Substation Event' (GOOSE) and of substituting the direct connection of binary I/O's of the Intelligent Electronic Devices also known as IED's. (author)

  9. Metodología para la implementación de un Sistema de Gestión de Seguridad de la Información basado en la familia de normas ISO/IEC 27000

    OpenAIRE

    Valencia-Duque, Francisco Javier; Orozco-Alzate, Mauricio

    2017-01-01

    Se propone una metodología de implementación de un Sistema de Gestión de Seguridad de la Información (SGSI) basado en la familia de normas de la ISO/IEC 27000, con énfasis en la interrelación de cuatro normas fundamentales a través de las cuales se desarrollan las actividades requeridas para cumplir con lo establecido en la ISO/IEC 27001, los controles de seguridad presentados en la ISO/IEC 27002, el esquema de riesgos de la ISO/IEC 27005 y los pasos recomendados en la ISO/IEC 27003. Se gener...

  10. Photoresponse in La0.9Hf0.1MnO3/0.05wt%Nb-doped SrTiO3 heteroepitaxial junctions

    Science.gov (United States)

    Qi, Yaping; Ni, Hao; Zheng, Ming; Zeng, Jiali; Jiang, Yucheng; Gao, Ju

    2018-05-01

    Excellent photo detectors need to have the rapid response and good repeatability from the requirement of industrial applications. In this paper, transport behavior and opto-response of heterostructures made with La0.9Hf0.1MnO3 and 0.05wt%Nb-doped SrTiO3 were investigated. The heterojunctions exhibited an excellent rectifying feature with very low leakage in a broad temperature region (from 40 to 300 K). These thin films presented persistent and stable photovoltages upon light illumination. Rapid shift between small and large voltages corresponding to "light OFF" and "light ON" states, respectively, was observed, demonstrating reliable photo detection behavior. A semiconductor laser with a wavelength of 650 nm was used as the light source. It is also noted that the observed photovoltages are strongly determined by light intensity. The injection of photoexcited charge carriers (electrons) could be responsible for the appearance of the observed opto-response. Such manipulative features by light irradiation exhibit great potential for light detectors for visible light.

  11. Photoresponse in La0.9Hf0.1MnO3/0.05wt%Nb-doped SrTiO3 heteroepitaxial junctions

    Directory of Open Access Journals (Sweden)

    Yaping Qi

    2018-05-01

    Full Text Available Excellent photo detectors need to have the rapid response and good repeatability from the requirement of industrial applications. In this paper, transport behavior and opto-response of heterostructures made with La0.9Hf0.1MnO3 and 0.05wt%Nb-doped SrTiO3 were investigated. The heterojunctions exhibited an excellent rectifying feature with very low leakage in a broad temperature region (from 40 to 300 K. These thin films presented persistent and stable photovoltages upon light illumination. Rapid shift between small and large voltages corresponding to “light OFF” and “light ON” states, respectively, was observed, demonstrating reliable photo detection behavior. A semiconductor laser with a wavelength of 650 nm was used as the light source. It is also noted that the observed photovoltages are strongly determined by light intensity. The injection of photoexcited charge carriers (electrons could be responsible for the appearance of the observed opto-response. Such manipulative features by light irradiation exhibit great potential for light detectors for visible light.

  12. International Standards Development for Marine and Hydrokinetic Renewable Energy - Final Report on Technical Status

    Energy Technology Data Exchange (ETDEWEB)

    Rondorf, Neil E.; Busch, Jason; Kimball, Richard

    2011-10-29

    This report summarizes the progress toward development of International Standards for Marine and Hydrokinetic Renewable Energy, as funded by the U.S. Department of Energy (DOE) under the International Electrotechnical Commission (IEC) Technical Committee 114. The project has three main objectives: 1. Provide funding to support participation of key U.S. industry technical experts in 6 (originally 4) international working groups and/or project teams (the primary standards-making committees) and to attend technical meetings to ensure greater U.S. involvement in the development of these standards. 2. Provide a report to DOE and industry stakeholders summarizing the IEC standards development process for marine and hydrokinetic renewable energy, new international standards and their justifications, and provide standards guidance to industry members. 3. Provide a semi-annual (web-based) newsletter to the marine renewable energy community. The newsletter will educate industry members and stakeholders about the processes, progress, and needs of the US efforts to support the international standards development effort. The newsletter is available at www.TC114.us

  13. Temperature behavior of 12 wt.% U TRIGA fuel

    Energy Technology Data Exchange (ETDEWEB)

    Levine, S H; Geisler, G C; Totenbier, R E [Pennsylvania State University (United States)

    1974-07-01

    Stainless steel clad 12 wt % U TRIGA fuel elements have been used to refuel the Penn State University's Breazeale Reactor (PSBR). When 12 wt % U fuel containing nominally 55 gms of {sup 235}U per fuel element is substituted for the 8.5 wt % U fuel containing nominally 38 gms {sup 235}U, higher fuel temperatures were produced in the 12 wt % U fuel than in the 8.5 wt % U fuel at the same reactor powers. The higher fuel temperature can be related to the higher power densities in the 12 wt % U fuel. The power density is calculated to be 35% higher in the 12 wt % U fuel when 6 of these fuel elements are substituted for 8.5 wt % U fuel in the innermost ring, the B ring. Temperatures have been calculated for the 12 wt % U fuel in the above configuration for both steady state and pulse conditions, assuming a 35% higher fuel density in the 12 wt % U fuel and the results compare favorably with the experimental measurements. This is particularly true when the comparison is made with temperature data taken after exposing the new fuel elements to a series of pulses. These calculations and data will be presented at the meeting. (author)

  14. Risikomanagement für medizinische Netzwerke in der Intensiv- und Notfallmedizin. Gemeinsames Positionspapier zur Norm IEC 80001-1 [Risk management for medical networks in intensive care and emergency medicine – a joint position paper on IEC 80001-1

    Directory of Open Access Journals (Sweden)

    Imhoff, Michael

    2013-02-01

    Full Text Available [english] IEC 80001-1 is an international standard and offers recommendations for a risk management process for medical information technology networks (MITs. MITs are defined as IT networks incorporating at least one medical device. The goal is to build and maintain reliable and secure MITs for hospitals of all kids. To achieve it, the standard suggests applying risk management and defines the roles involved as well as their responsibilities. A central role is the medical IT-network risk manager, assigned by the top management of organizations. He communicates with and mediates between clinical, medical device and IT divisions and compiles risk relevant facts usually distributed among them. All identified risks are analyzed, evaluated and documented in the risk management file along with counter measures and a final assessment of acceptability.We acknowledge that implementing the suggested process will create an overhead cost in documentation and – partly by extension – in personnel. However we believe that the investment at the start of projects is worthwhile, because it helps to prevent or solve problems in later stages. Especially consecutive projects can profit from the investment, reducing required effort and costs. Furthermore, a reliable and secure MIT forms the basis for frictionless routine operations and innovations for connected medical devices. Hence the investment is justified. Applying risk management to the whole cooperation all at once is unrealistic. Focusing on parts of the network, which are crucial to a new project is more recommendable. With a smaller scope, risk management remains feasible and can later be expanded to other parts of the network.IEC 80001-1 demands communication among involved employees from different specialties and divisions. This offers a chance for cooperation to find better decisions and solutions regarding an organization’s medical IT network.[german] Die IEC 80001-1 ist eine Norm, die

  15. Register of international standard NP on IT based wireless application in nuclear power plants

    International Nuclear Information System (INIS)

    Koo, I. S.; Hong, S. B.; Cho, I. W.; Choi, Y. S.; Lee, J. C.

    2011-04-01

    DC draft of standard technical report for wireless applications in NPP is developed, which is a Korean IT technologies. Wireless technologies are forwardwd to converging technologies nuclear and IT area. These technologies are supported to reduce vulnerability against cyber attacks and are forwarded to international standards which met with the nuclear environment requirements. DC draft of standard technical report is provided and circulated. Korean experts participate in Plenary meeting for IEC TC45/SC45A and intermediate meeting for IEC SC45A/WGA3 and 9. Korean expert takes the chair of wireless session at ANS winter conference. Visible light communication is experimented for feasibility study on reducing vulnerability against cyber attacks. VLC is capable of robust wireless communication against cyber attacks. This is suggested to describe a method for technical report. Issue DTR for wireless applications in NPP in 2012

  16. Present status of standards relating to radiation control and protection

    International Nuclear Information System (INIS)

    Minami, Kentaro

    1996-01-01

    Japanese and international standards related to radiation control and radiation protective management are presented focusing on the forming condition, significance, current situation, and their relationship. Japanese Industrial Standards (JIS) is quite useful in the field of atomic energy as well as other fields in terms of optimization and rationalization of the management. JIS includes JIS Z 4001 Atomic Energy Terminology which corresponds to internationl standards ISO 921 Nuclear Glossary, and JIS Z 4005 Medical Radiation Terminology, covering about 500 articles, which corresponds to IEC 788 Medical Radiology-Terminology. The first standards regarding radiation protection was established in X-ray Film Badge, which is included in the field of personal dosimeter, in 1956. Currently, 36 JIS has been established in the field of radiation management dosimeter and 3 are under arrangement. As for radiation protective supplies, 9 JIS has been established so far. Before proposal of JIS, investigation had been conducted to improve, simplify, and standardize the standards of radiation dosimetric technique, dosimeters, dosimetric procedures, and improvement. In this article, the results of material surface contamination monitoring and body surface monitoring conducted in Atomic Energy Safety Association and Radiation Dosimetry Associationare reported, and ISO and IEC are also treated. (S.Y.)

  17. Parametrics for Molecular Deuterium Concentrations in the Source Region of the UW-IEC Device Using an Ion Acoustic Wave Diagnostic

    Science.gov (United States)

    Boris, D. R.; Emmert, G. A.

    2007-11-01

    The ion source region of the UW-Inertial Electrostatic Confinement device is comprised of a filament assisted DC discharge plasma that exists between the wall of the IEC vacuum chamber and the grounded spherical steel grid that makes up the anode of the IEC device. A 0-dimensional rate equation calculation of the molecular deuterium ion species concentration has been applied utilizing varying primary electron energy, and neutral gas pressure. By propagating ion acoustic waves in the source region of the IEC device the concentrations of molecular deuterium ion species have been determined for these varying plasma conditions, and high D3^+ concentrations have been verified. This was done by utilizing the multi-species ion acoustic wave dispersion relation, which relates the phase speed of the multi-species ion acoustic wave, vph, to the sum in quadrature of the concentration weighted ion acoustic sound speeds of the individual ion species.

  18. Complementing network security to the ISO/IEC 27000 standard

    OpenAIRE

    Alila, Patrick

    2007-01-01

    I syfte att öppna upp nya affärsmöjligheter för informationssäkerhetsföretaget Secure State AB, har detta arbete bedrivits för att komplettera företagets nuvarande standard för informationssäkerhetsarbete med ytterligare nätverkssäkerhet. Krav på slutresultatet var att dokumentet eller standarden skulle kunna komplettera ISO 27000, samt vara kostnadseffektivt. Efter en undersökning av den nämnda standarden konstaterades att enbart ISO 27000 i sig inte är ett fullgott verktyg för nätverkssäker...

  19. Stabilization effect of Zr and Ti additions on the ageing characteristics of Al-1 wt% Si alloy through a creep study

    Energy Technology Data Exchange (ETDEWEB)

    Deaf, G.H.; Beshai, M.H.N.; Abd El Khalek, A.M.; Graiss, G. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics; Kenawy, M.A. [Ain Shams Univ., Cairo (Egypt). Womens Coll.

    1997-12-31

    Al-1 wt% Si and Al-1 wt% Si-0.1 wt% Zr-0.1 wt% Ti alloys were used to trace the effect of Zr and Ti additions on the behaviour of the steady state creep. After solid solution treatment specimens of both alloys were aged at 623, 673, 723 and 773 K and creep tests were performed at room temperature by applying stresses of 60.0, 62.4, 64.7 and 67.1 MPa. The results showed a sound stabilization effect of Zr and Ti on the ageing characteristics of binary Al-1 wt% Si alloy. Values of the applied stress sensitivity parameter, m, obtained were in the range of (20-34) for Al-Si alloy and (14-19) for Al-Si-Zr-Ti alloy. Time to rupture was found to be strongly increased by Zr and Ti additions. The activation energies of the precipitation process involved were found to be 81.9 kJ/mole and 33.7 kJ/mole of the Al-Si and Al-Si-Zr-Ti alloys respectively. (orig.) 17 refs.

  20. Characteristics and corrosion studies of vanadate conversion coating formed on Mg–14 wt%Li–1 wt%Al–0.1 wt%Ce alloy

    International Nuclear Information System (INIS)

    Ma Yibin; Li Ning; Li Deyu; Zhang Milin; Huang Xiaomei

    2012-01-01

    Highlights: ► Vanadate film forms on the surface of Mg–Li–Al–Ce alloy. ► Vanadate coating improves the corrosion resistance. ► Vanadate coating is composed of Mg(OH) 2 , Li 2 O and V 2 O 5 . - Abstract: Mg–14Li–1Al–0.1Ce alloy is immersed in NH 4 VO 3 + K 3 (Fe(CN) 6 ) solutions with different NH 4 VO 3 and/or K 3 (Fe(CN) 6 ) concentrations, and different immersion time. The surface morphology and composition of the vanadate coating are then characterized by scanning electron microscopy with energy dispersion spectroscopy (SEM-EDS) and X-ray photoelectron spectroscopy (XPS), and the corrosion behavior of the conversion coating is studied by polarization technique and electrochemical impedance spectroscopy (EIS). The experimental results indicate that the vanadate film with better corrosion resistance forms on Mg–Li–Al–Ce surface after the sample is immersed in 30 g L −1 NH 4 VO 3 + 3.75 g L −1 K 3 (Fe(CN) 6 ) solution at 80 °C for 10 min. The coating consists of V 2 O 5 , Li 2 O and Mg(OH) 2 .

  1. Characteristics and corrosion studies of vanadate conversion coating formed on Mg-14 wt%Li-1 wt%Al-0.1 wt%Ce alloy

    Energy Technology Data Exchange (ETDEWEB)

    Ma Yibin [School of Chemical Engineering and Technology, Harbin Institute of Technology, Harbin 150001 (China); Li Ning, E-mail: lininghit@263.net [School of Chemical Engineering and Technology, Harbin Institute of Technology, Harbin 150001 (China); Li Deyu [School of Chemical Engineering and Technology, Harbin Institute of Technology, Harbin 150001 (China); Zhang Milin; Huang Xiaomei [Key Laboratory of Superlight Materials and Surface Technology, Ministry of Education, Harbin Engineering University, Harbin 150001 (China)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Vanadate film forms on the surface of Mg-Li-Al-Ce alloy. Black-Right-Pointing-Pointer Vanadate coating improves the corrosion resistance. Black-Right-Pointing-Pointer Vanadate coating is composed of Mg(OH){sub 2}, Li{sub 2}O and V{sub 2}O{sub 5}. - Abstract: Mg-14Li-1Al-0.1Ce alloy is immersed in NH{sub 4}VO{sub 3} + K{sub 3}(Fe(CN){sub 6}) solutions with different NH{sub 4}VO{sub 3} and/or K{sub 3}(Fe(CN){sub 6}) concentrations, and different immersion time. The surface morphology and composition of the vanadate coating are then characterized by scanning electron microscopy with energy dispersion spectroscopy (SEM-EDS) and X-ray photoelectron spectroscopy (XPS), and the corrosion behavior of the conversion coating is studied by polarization technique and electrochemical impedance spectroscopy (EIS). The experimental results indicate that the vanadate film with better corrosion resistance forms on Mg-Li-Al-Ce surface after the sample is immersed in 30 g L{sup -1} NH{sub 4}VO{sub 3} + 3.75 g L{sup -1} K{sub 3}(Fe(CN){sub 6}) solution at 80 Degree-Sign C for 10 min. The coating consists of V{sub 2}O{sub 5}, Li{sub 2}O and Mg(OH){sub 2}.

  2. Classification of different kinds of pesticide residues on lettuce based on fluorescence spectra and WT-BCC-SVM algorithm

    Science.gov (United States)

    Zhou, Xin; Jun, Sun; Zhang, Bing; Jun, Wu

    2017-07-01

    In order to improve the reliability of the spectrum feature extracted by wavelet transform, a method combining wavelet transform (WT) with bacterial colony chemotaxis algorithm and support vector machine (BCC-SVM) algorithm (WT-BCC-SVM) was proposed in this paper. Besides, we aimed to identify different kinds of pesticide residues on lettuce leaves in a novel and rapid non-destructive way by using fluorescence spectra technology. The fluorescence spectral data of 150 lettuce leaf samples of five different kinds of pesticide residues on the surface of lettuce were obtained using Cary Eclipse fluorescence spectrometer. Standard normalized variable detrending (SNV detrending), Savitzky-Golay coupled with Standard normalized variable detrending (SG-SNV detrending) were used to preprocess the raw spectra, respectively. Bacterial colony chemotaxis combined with support vector machine (BCC-SVM) and support vector machine (SVM) classification models were established based on full spectra (FS) and wavelet transform characteristics (WTC), respectively. Moreover, WTC were selected by WT. The results showed that the accuracy of training set, calibration set and the prediction set of the best optimal classification model (SG-SNV detrending-WT-BCC-SVM) were 100%, 98% and 93.33%, respectively. In addition, the results indicated that it was feasible to use WT-BCC-SVM to establish diagnostic model of different kinds of pesticide residues on lettuce leaves.

  3. Reliability Prediction Approaches For Domestic Intelligent Electric Energy Meter Based on IEC62380

    Science.gov (United States)

    Li, Ning; Tong, Guanghua; Yang, Jincheng; Sun, Guodong; Han, Dongjun; Wang, Guixian

    2018-01-01

    The reliability of intelligent electric energy meter is a crucial issue considering its large calve application and safety of national intelligent grid. This paper developed a procedure of reliability prediction for domestic intelligent electric energy meter according to IEC62380, especially to identify the determination of model parameters combining domestic working conditions. A case study was provided to show the effectiveness and validation.

  4. CALCULATION AND EXPERIMENTAL ESTIMATION OF RESULTS OF ELECTRO-THERMAL ACTION OF RATIONED BY THE INTERNATIONAL STANDARD IEC 62305-1-2010 IMPULSE CURRENT OF SHORT BLOW OF ARTIFICIAL LIGHTNING ON THE THIN-WALLED COVERAGE FROM STAINLESS STEEL

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2017-03-01

    Full Text Available Purpose. Calculation and experimental researches of electro-thermal resistibility of the pre-production thin-walled sheet models of outward roof of height technical buildings from stainless steel are easily soiled 12Х18Н10Т to direct action on them rationed by the International Standard IEC 62305-1-2010 aperiodic impulse of current of short bow of artificial lightning of temporal form 10/350 μs with the proper admittances on his peak-temporal parameters (PTP. Methodology. Electrophysics bases of technique of high voltage and large impulsive currents (LIC, and also scientific and technical bases of planning of high-voltage impulsive devices and measuring methods in them LIC with followings below extreme PTP: amplitude of impulse of current of ImL=200 кА (with admittance ±10 %; integral of action of impulse of current of JL=10·106 A2·s (with admittance ±35 %; %; duration of wavefront current of T1=10 μs (with admittance ±20 %; time, proper amplitude of impulse of current of ImL, tmL≤24 μs (with admittance ±20 %; duration of flowing of impulse of current of T2=350 μs (with admittance ±10 %. Results. The results of evaluation calculation and experimental researches of electro-thermal resistibility of the indicated pre-production sheet models are resulted measuring in the plan of 0,5 x 0,5 m from stainless steel are easily soiled the 12Х18Н10Т thickness of 1 mm to action on them of aperiodic impulse of current of short blow of artificial lightning with rationed PTP on the requirements of the International Standard IEC 62305-1-2010. In high current experiments amplitude of ImL of the aperiodic rationed impulse of current of artificial lightning of temporal form of T1/T2=15 μs/315 μs changed in the range of (100-184 кА. The integral of action of JL of impulse of current for I-IV of levels of protection of lightning of technical objects (TO numeral made from 2,32·106 А2·s to 7,88·106 А2·s, and the flowing through the

  5. On the long-term stability of calibration standards in different matrices.

    Science.gov (United States)

    Kandić, A; Vukanac, I; Djurašević, M; Novković, D; Šešlak, B; Milošević, Z

    2012-09-01

    In order to assure Quality Control in accordance with ISO/IEC 17025, it was important, from metrological point of view, to examine the long-term stability of calibration standards previously prepared. Comprehensive reconsideration on efficiency curves with respect to the ageing of calibration standards is presented in this paper. The calibration standards were re-used after a period of 5 years and analysis of the results showed discrepancies in efficiency values. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Generation of a plan for the implementation of INTE/ISO IEC 17025 in a paint industry and modification of a quality manual

    International Nuclear Information System (INIS)

    Salazar Gomez, Andrea Marcela

    2014-01-01

    A diagnosis to the integrated management system and quality control laboratories is done in a paint industry. The administrative aspects related with the documentation are evaluated: procedures, instructions, records, processes of sampling, testing, for possible accreditation of some methods of analysis under the norm ISO/IEC 17025 representing an opportunity for growth and improvement in labs. The laboratories of the paint industry have analyzed a number of materials such as products for the various stages of construction and beautification of homes, buildings and other, as well as evaluation of the requirements established by international standards to demonstrate competence regarding these. The feasibility of implementing the standard is visualized, solving the disagreements that have been found during the evaluation period. The impact of the perception of quality is determined by the direction, the need for investment in resources, training and equipment. (author) [es

  7. Tailoring ISO/IEC 27001 for SMEs: A Guide to Implement an Information Security Management System in Small Settings

    Science.gov (United States)

    Valdevit, Thierry; Mayer, Nicolas; Barafort, Béatrix

    While Information Security Management Systems (ISMS) are being adopted by the biggest IT companies, it remains quite difficult for smaller entities to implement and maintain all the requirements of ISO/IEC 27001. In order to increase information security in Luxembourg, the Public Research Centre Henri Tudor has been charged by the Luxembourg Ministry of Economy and Foreign Trade to find solutions to facilitate ISMS deployment for SMEs. After an initial experiment aiming at assisting a SME in getting the first national ISO/IEC 27001 certification for a private company, an implementation guide for deploying an ISMS, validated by local experts and experimented in SMEs, has been released and is presented in this paper.

  8. Cylindrical IEC neutron source design for driven research reactor operation

    International Nuclear Information System (INIS)

    Miley, G.H.; Ulmen, B.; Amadio, G.; Leon, H.; Hora, H.

    2009-01-01

    A resurgence in nuclear power use is now underway worldwide. However, due many university research reactors shutdown, they must rely on using subcritical assemblies which employs a cylindrical Inertial Electrostatic Confinement (IEC) device to provide a fusion neutron source. The source is inserted in a fuel element position, with its power input controlled externally at a control panel. This feature opens the way to use of the critical assembly for a number of transient experiments such as sub-critical pulsing and neutron wave propagation. That in turn adds important new insights and excitement for the student teaching laboratory. (author)

  9. Experience with nuclear safety standards development in non-governmental international organizations

    International Nuclear Information System (INIS)

    Becker, K.

    1985-01-01

    Besides the IAEA as a 'governmental' organization dealing with basic safety recommendations addressed primarily to the national regulatory bodies in developing countries, two closely related non-governmental international standards organizations have gained extensive experience in the field of nuclear standardization. Over more than 25 years since their formation, both (a) the International Organization for Standardization's (ISO) Technical Committee 85 'Nuclear Energy', in particular in its Sub-Committee 3 'Reactor Technology and Safety' and (b) the International Electrotechnical Commission's (IEC) Technical Committee 45 'Nuclear Instrumentation' have published numerous standards. A brief review is given of these, draft standards, and other documents planned to become international standards. Many of them deal with rather specialized topics typical for 'industrial' standards such as standardized procedures, instruments, methods, materials, test methods, terminology, and signs and symbols, but others are directly related to more basic safety issues. In some areas such as quality assurance, seismic aspects of siting and terminology, there has been in the past occasional overlap in the activities of the NUSS programme, IEC and ISO. Letters of Understanding have since 1981 contributed to clarifying the borderlines and to avoiding redundant efforts. Also, some experiences and problems are described arising, for example, from the harmonization of different national safety philosophies and traditions into universally accepted international standards, and the transfer of international standards into national standards systems. Finally, based on a recent comprehensive compilation of some 3300 nuclear standards and standards projects, an attempt is made to present a cost/benefit analysis and an outlook on future developments. (author)

  10. Microstructural morphologies of slag based glass-ceramics nucleated with 5 wt% Cr{sub 2}O{sub 3} and 5 wt% Cr{sub 2}O{sub 3} + 5 wt% TiO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Oevecoglu, M.L.; Oezkal, B. [Istanbul Technical Univ. (Turkey). Dept. of Metallurgical and Materials Enginering; Catakli, E. [Mimar Sinan Univ., Istanbul (Turkey). Faculty of Science and Literature; Erkmen, Z.E. [Istnabul Univ. (Turkey). Dept. of Metallurgical Engineering

    2002-07-01

    Glass-ceramic materials were developed from the blast-furnace slags by mixing 5 wt% Cr{sub 2}O{sub 3} and 5 wt% Cr{sub 2}O{sub 3} + 5 wt% TiO{sub 2}. The samples were nucleated for 18 h at 780 C and crystallized for 20 min. at 905 C, respectively. SEM and SEM/EDS investigations revealed the presence of clover-shaped TiO{sub 2} particles in the glassy matrix of the sample nucleated with 5 wt% Cr{sub 2}O{sub 3} + 5 wt% TiO{sub 2} and polygonal-shaped Cr{sub 2}O{sub 3} platelets for both samples. XRD scans revealed the presence of akermanite (2CaO.MgO.2SiO{sub 2}) and gehlenite (2CaO.Al{sub 2}O{sub 3}.SiO{sub 2}) peaks indicating the existence of the mellilite solid solution for the crystallized glass-ceramic samples. (orig.)

  11. Effect of conventional and subzero treating on the mechanical properties of aged martensitic Fe-12 wt.% Ni-X wt.% Mn alloys

    International Nuclear Information System (INIS)

    Nedjad, S. Hossein; Nili-Ahmadabadi, M.; Mahmudi, R.; Farhangi, H.

    2003-01-01

    Fe-Ni-Mn maraging alloys are suffering from sever embrittlement after aging. Mechanism of the embrittelement has not been well understood yet. Segregation of Mn atoms or formation of Austenite particles at prior Austenite grain boundaries (PAGBs) have been reported as embrittelement mechanisms while it remains controversial now. For better understanding of embrittelement behavior, effect of subzero treating after aging, double aging and modification of alloy composition on the mechanical properties and fracture behavior were investigated. Alloys of chemical compositions Fe-11.9 wt.% Ni-6.3 wt.% Mn and Fe-10.5 wt.% Ni-5.8 wt.% Mo-3 wt.% Mn were studied. Double solution annealing was performed at 1223 and 1093 K for 3.6 ks followed by water quenching. After aging at 723 K for 0.9 ks (under aging) and 172.8 ks (over aging), tensile properties of specimens heat treated conventionally and cryogenically were measured. Double aging was done at 623 K for 3.6 ks followed by a step aging at 753, 783 and 803 K. Aging behavior and tensile properties of Fe-10.5 wt.% Ni-5.8 wt.% Mo-3 wt.% Mn were investigated after aging at 773 K. Results showed that alloy modification yields reasonable tensile properties while subzero treatment and double aging couldn't improve tensile properties. An insight toward more investigation of the embrittelement mechanism was made on the basis of this study

  12. Experimental determination of the H2O + 15 wt% NaCl and H2O + 25 wt% NaCl liquidi to 1.4 GPa

    Science.gov (United States)

    Valenti, P.; Schmidt, C.

    2009-12-01

    1380 MPa, 12.7°C for 25 wt% NaCl. At lower pressures (except at 0.1 MPa and 15 wt%NaCl), the last solid was hydrohalite. Hydrohalite was identified based on crystal shape, its higher density and index of refraction relative to those of the liquid, and Raman spectra. For both bulk compositions, the liquidus displayed negative dP/dT slopes to ~100 MPa, and positive dP/dT slopes above that pressure. The transition from negative to positive dP/dT slopes occurred without a change of the liquidus solid (hydrohalite), which suggests a relationship to anomalous properties of the aqueous liquid. This finding is consistent with literature data for the halite liquidus of H2O + 40 wt% NaCl (Schmidt et al. 1998). Generally, addition of NaCl steepens the liquidi. The dP/dT slopes of the ice VI liquidus of the 15 and 25 wt% NaCl solutions obtained in this study are steeper than that of the ice VI melting curve of pure water (Wagner et al. 1994), but shallower than reported for a H2O + 5.5 wt% NaCl solution (Manning and Daniel 2008).

  13. Development of standard technical report on using and selecting wireless device in nuclear power plants

    International Nuclear Information System (INIS)

    Koo, I. S.; Hong, S. B.; Cho, J. W.

    2011-11-01

    1. Purpose · Development of IEC technical report on wireless device using in nuclear power plants 2. Contents · IEC technical reports of draft for circulation and final draft for next planary meeting · Case study on experiment of wireless devices 3. Implementation methods · Preparation of first draft with experts group, its circulation, discussions on the results of the circulation · Organizing three teams such as preparation, reviews and experiment 4. Results · Maintenance cost will be reduced with application of the wireless technologies in nuclear power plants · Commercial wireless devices will be developed before standard is issued

  14. Software life cycle management standards real-world solutions and scenarios for savings

    CERN Document Server

    Wright, David

    2011-01-01

    Software Life Cycle Management Standards will help you apply ISO/IEC 19770 to your business and enjoy the rewards it offers. David Wright calls on his vast experience to explain how the Standard applies to the whole of the software life cycle, not just the software asset management aspects. His informative guide gives up-to-date information using practical examples, clear diagrams and entertaining anecdotes.

  15. Excerpt from: Testing of radiotherapy dosimeters in accordance with specifications given by IEC publication 731 (1982)

    International Nuclear Information System (INIS)

    Jaervinen, Hannu; Rantanen, Erkii; Jokela, Kari

    1986-01-01

    In their position as centres for expertise in radiation dosimetry and its applications, the Secondary Standard Dosimetry Laboratories (SSDLs) are expected to advise the radiation users, the radiotherapy centres in particular, in selection and use of the most suitable dosimetric equipment. Various dosimeters are commercially available, but objective information on their fundamental technical characteristics is lacking. Such information would be valuable and necessary for the SSDLs to be able to judge the accuracy and reliability of the many choices which exist for a given application. The results of systematic evaluations of dosimeters in a recognized SSDL (or SSDLs) could be helpful supplementary information to the other SSDLs and to the radiation users. In 1983 The Finnish Centre for Radiation and Nuclear Safety (STUK; old name: Institute of Radiation Protection) and the International Atomic Energy Agency (IAEA) made a research contract, the purpose of which was to test selected dosimeters for use in radiotherapy in accordance with the specifications by the International Electrotechnical Commission (IEC)

  16. Characterization of a PET-NEMA/IEC body phantom for quality control tests of PET/CT equipment

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Vieira, Igor F.; Lima, Fernando R.A.; Sa, Lidia V. de

    2011-01-01

    The Brazilian Sanitary Agency from Ministry of Health requires that all PET/CT equipment must undergo minimal quality control tests using manufacturer simulators. The PET-NEMA/IEC body phantom is recommended by the IEC and NEMA to perform acceptance testing and quality control in PET/CT equipment according to specific protocols. It is essential that all simulator components (spheres and body) are properly characterized in relation to their size and internal structure volumes, since they are used to calculate the overall activity concentration and the total weight. The objective of this work was characterize a PET-NEMA/IEC body phantom for the true reconstruction in computational modeling and correct analysis of experimental results. The simulator is basically composed of three structures: the body (simulating a portion of the chest), an inner cylinder (simulating the lung tissue) and a top cover in which are coupled spheres of different sizes simulating 'hot' (tumors) and cold lesions. The spheres were evaluated in terms of volume. The same evaluations were performed with the body of the simulator and the inner cylinder, beyond of analysis of their weights (filled with water) and wall thickness. The data showed that the total weight of the simulator with all its internal structures is 12.5 kg and the volume of the 'hot' and 'cold' spheres are approximately equal to those presented by the manufacturer. The inner cylinder volume showed a significant difference between the measured and the presented in the manual. The results were used for reconstruction of the simulator in computational modeling using the code GATE. (author)

  17. Importance of the Primary Radioactivity Standard Laboratory and Implementation of its Quality Management

    Science.gov (United States)

    Sahagia, Maria; Razdolescu, Anamaria Cristina; Luca, Aurelian; Ivan, Constantin

    2007-04-01

    The paper presents some specific aspects of the implementation of the quality management in the Radionuclide Metrology Laboratory, from IFIN-HH, the owner of the primary Romanian standard in radioactivity. The description of the accreditation, according to the EN ISO/IEC 17025:2005, is presented.

  18. Importance of the Primary Radioactivity Standard Laboratory and Implementation of its Quality Management

    International Nuclear Information System (INIS)

    Sahagia, Maria; Razdolescu, Anamaria Cristina; Luca, Aurelian; Ivan, Constantin

    2007-01-01

    The paper presents some specific aspects of the implementation of the quality management in the Radionuclide Metrology Laboratory, from IFIN-HH, the owner of the primary Romanian standard in radioactivity. The description of the accreditation, according to the EN ISO/IEC 17025:2005, is presented

  19. Top Polarisation in H-t and Wt production

    International Nuclear Information System (INIS)

    Godbole, R.M.; Hartgring, L.; Niessen, I.; White, C.D.

    2012-01-01

    We consider laboratory frame observables (like the azimuthal angle between the top quark and its decay lepton or the polar angle between the top quark and leptonic directions) obtained from leptonic decay products of top quarks produced in association with a charged Higgs or W boson. These are robust against QCD corrections to top quark decay, and can be used to pin down the parameter space of a charged Higgs boson, or reduce backgrounds in H - t and (Standard Model) Wt production. Polarisation information can efficiently be used to distinguish single top quark production processes from their backgrounds, as well as to pin down the parameters of a charged Higgs boson model

  20. HLA-A*01:03, HLA-A*24:02, HLA-B*08:01, HLA-B*27:05, HLA-B*35:01, HLA-B*44:02, and HLA-C*07:01 Monochain Transgenic/H-2 Class I Null Mice

    DEFF Research Database (Denmark)

    Boucherma, Rachid; Kridane-Miledi, Hédia; Bouziat, Romain

    2013-01-01

    We have generated a panel of transgenic mice expressing HLA-A*01:03, -A*24:02, -B*08:01, -B*27:05, -B*35:01, -B*44:02, or -C*07:01 as chimeric monochain molecules (i.e., appropriate HLA α1α2 H chain domains fused with a mouse α3 domain and covalently linked to human β2-microglobulin). Whereas...... a quantitative and qualitative restoration of the peripheral CD8(+) T cell repertoire, which exhibited a TCR diversity comparable with C57BL/6 WT mice. Potent epitope-specific, HLA-restricted, IFN-γ-producing CD8(+) T cell responses were generated against known reference T cell epitopes after either peptide...

  1. Re-Establishment of Standard Radiation Qualities for Calibration of Dosemeter in Diagnostic Radiology - RQR Series

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Norhayati Abdullah; Mohd Firdaus Abd Rahman

    2016-01-01

    After repairing the high voltage (HV) generator for Philips MG165 X-Ray Machine, the reestablishment of the standard radiation qualities has been done at Medical Physics Calibration Laboratory to meet the IEC and IAEA standard. Standard radiation qualities are the important criteria for calibration of dosemeter in diagnostic radiology. Standard radiation qualities are defined as the added filtration needed to produce and the half value layer (HVL) of the beam for specifies x-ray tube kilo voltage (kV). For calibration of dosemeter in diagnostic radiology, standard radiation qualities RQR represent the beam incident on the patient in general radiography, fluoroscopy and dental application. The HVL were measured using PTW ion chamber of volume 1 cm"3 with PTW electrometer and aluminium filter with 99.9 % purity was used as additional filter for RQR and filter for HVL. The first establishment of standard radiation qualities was made in 2009 for the radiation qualities of RQR. The results of additional filter and 1st HVL from 2009 to 2016 will be discussed further in paper. The ratios of the measured HVL to the standard IEC HVL value for the RQR series also described in this paper. The details of the measurement and the results are described in this paper. (author)

  2. Implementation of IEC Generic Model of Type 1 Wind Turbine Generator in DIgSILENT PowerFactory

    DEFF Research Database (Denmark)

    Zhao, Haoran; Wu, Qiuwei; Margaris, Ioannis

    2013-01-01

    The implementation method for the International Electrotechnical Commission (IEC) generic models of Type 1 wind turbine generator (WTG) in DIgSILENT PowerFactory is presented. The following items are described, i.e. model structure, model blocks and how to implement these blocks in the PowerFactory...

  3. Protective Effect of Wheat Peptides against Indomethacin-Induced Oxidative Stress in IEC-6 Cells

    Directory of Open Access Journals (Sweden)

    Hong Yin

    2014-01-01

    Full Text Available Recent studies have demonstrated that wheat peptides protected rats against non-steroidal anti-inflammatory drugs-induced small intestinal epithelial cells damage, but the mechanism of action is unclear. In the present study, an indomethacin-induced oxidative stress model was used to investigate the effect of wheat peptides on the nuclear factor-κB(NF-κB-inducible nitric oxide synthase-nitric oxide signal pathway in intestinal epithelial cells-6 cells. IEC-6 cells were treated with wheat peptides (0, 125, 500 and 2000 mg/L for 24 h, followed by 90 mg/L indomethacin for 12 h. Wheat peptides significantly attenuated the indomethacin-induced decrease in superoxide dismutase and glutathione peroxidase activity. Wheat peptides at 2000 mg/L markedly decreased the expression of the NF-κB in response to indomethacin-induced oxidative stress. This study demonstrated that the addition of wheat peptides to a culture medium significantly inhibited the indomethacin-induced release of malondialdehyde and nitrogen monoxide, and increased antioxidant enzyme activity in IEC-6 cells, thereby providing a possible explanation for the protective effect proposed for wheat peptides in the prevention of indomethacin-induced oxidative stress in small intestinal epithelial cells.

  4. Measurement of high temperature elastic moduli of an 18Cr-9Ni-2.95 Cu-0.58 Nb-0.1C (Wt %) austenitic stainless steel

    Science.gov (United States)

    Tripathy, Haraprasanna; Hajra, Raj Narayan; Sudha, C.; Raju, S.; Saibaba, Saroja

    2018-04-01

    The Young's modulus (E) and Shear modulus (G) of an indigenously developed 18Cr-9Ni-0.1C-2.95 Cu-0.58Nb (wt %) austenitic stainless steel has been evaluated in the temperature range 298 K to 1273 K (25 °C to 1000 °C), using Impulse excitation technique (IET). The Bulk modulus (K) and the poison's ratio have been estimated from the measured values of E and G. It is observed that the elastic constants (E, G and K) are found to decrease in a nonlinear fashion with increase in temperature. The Cu precipitation is found to influence the elastic moduli of the steel in the cooling cycle. The observed elastic moduli are fitted to 3rd order polynomial equations in order to describe the temperature dependence of E, G, K moduli in the temperature range 298-1273 K (25 °C to 1000 °C). The room temperature values of E,G and K moduli is found to be 207, 82 and 145 GPa respectively for the present steel.

  5. Hardness and microstructure of Al-10.0 wt% Zn-4.0 wt% Mg alloy

    International Nuclear Information System (INIS)

    Iqbal, M.; Shaikh, M.A.; Ahmad, W.; Ali, K.L.

    1996-01-01

    Al-Zn-Mg alloys are widely used in industries as these have excellent physical and mechanical properties. However some aspects of the effect of heat treatment on these alloys are not yet clear. In order to understand the precipitation phenomena in these alloys, microstructure of a locally prepared alloy Al-10.0 wt% Zn-4.0 wt% Mg heat treated under different conditions has been examined in scanning electron microscope/electron probe micro analyser. Precipitates MgZn/sub 2/, MgZn/sub 4/ and Mg/sub 2/Zn/sub 11/ have been observed and these are caused by heat treatment. Correlation between these precipitates and Vickers's hardness has also been studied. In the present paper results of this investigation have been presented and discussed. (author)

  6. Multiscale modeling of a low magnetostrictive Fe-27wt%Co-0.5wt%Cr alloy

    Science.gov (United States)

    Savary, M.; Hubert, O.; Helbert, A. L.; Baudin, T.; Batonnet, R.; Waeckerlé, T.

    2018-05-01

    The present paper deals with the improvement of a multi-scale approach describing the magneto-mechanical coupling of Fe-27wt%Co-0.5wt%Cr alloy. The magnetostriction behavior is demonstrated as very different (low magnetostriction vs. high magnetostriction) when this material is submitted to two different final annealing conditions after cold rolling. The numerical data obtained from a multi-scale approach are in accordance with experimental data corresponding to the high magnetostriction level material. A bi-domain structure hypothesis is employed to explain the low magnetostriction behavior, in accordance with the effect of an applied tensile stress. A modification of the multiscale approach is proposed to match this result.

  7. Chemical chaperones reduce ionizing radiation-induced endoplasmic reticulum stress and cell death in IEC-6 cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sang; Lee, Hae-June; Lee, Yoon-Jin [Division of Radiation Effects, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of); Jeong, Jae-Hoon [Division of Radiotherapy, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of); Kang, Seongman [Division of Life Sciences, Korea University, Seoul 136-701 (Korea, Republic of); Lim, Young-Bin, E-mail: yblim@kirams.re.kr [Division of Radiation Effects, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of)

    2014-07-25

    Highlights: • UPR activation precedes caspase activation in irradiated IEC-6 cells. • Chemical ER stress inducers radiosensitize IEC-6 cells. • siRNAs that targeted ER stress responses ameliorate IR-induced cell death. • Chemical chaperons prevent cell death in irradiated IEC-6 cells. - Abstract: Radiotherapy, which is one of the most effective approaches to the treatment of various cancers, plays an important role in malignant cell eradication in the pelvic area and abdomen. However, it also generates some degree of intestinal injury. Apoptosis in the intestinal epithelium is the primary pathological factor that initiates radiation-induced intestinal injury, but the mechanism by which ionizing radiation (IR) induces apoptosis in the intestinal epithelium is not clearly understood. Recently, IR has been shown to induce endoplasmic reticulum (ER) stress, thereby activating the unfolded protein response (UPR) signaling pathway in intestinal epithelial cells. However, the consequences of the IR-induced activation of the UPR signaling pathway on radiosensitivity in intestinal epithelial cells remain to be determined. In this study, we investigated the role of ER stress responses in IR-induced intestinal epithelial cell death. We show that chemical ER stress inducers, such as tunicamycin or thapsigargin, enhanced IR-induced caspase 3 activation and DNA fragmentation in intestinal epithelial cells. Knockdown of Xbp1 or Atf6 with small interfering RNA inhibited IR-induced caspase 3 activation. Treatment with chemical chaperones prevented ER stress and subsequent apoptosis in IR-exposed intestinal epithelial cells. Our results suggest a pro-apoptotic role of ER stress in IR-exposed intestinal epithelial cells. Furthermore, inhibiting ER stress may be an effective strategy to prevent IR-induced intestinal injury.

  8. Study on AC loss measurements of HTS power cable for standardizing

    Science.gov (United States)

    Mukoyama, Shinichi; Amemiya, Naoyuki; Watanabe, Kazuo; Iijima, Yasuhiro; Mido, Nobuhiro; Masuda, Takao; Morimura, Toshiya; Oya, Masayoshi; Nakano, Tetsutaro; Yamamoto, Kiyoshi

    2017-09-01

    High-temperature superconducting power cables (HTS cables) have been developed for more than 20 years. In addition of the cable developments, the test methods of the HTS cables have been discussed and proposed in many laboratories and companies. Recently the test methods of the HTS cables is required to standardize and to common in the world. CIGRE made the working group (B1-31) for the discussion of the test methods of the HTS cables as a power cable, and published the recommendation of the test method. Additionally, IEC TC20 submitted the New Work Item Proposal (NP) based on the recommendation of CIGRE this year, IEC TC20 and IEC TC90 started the standardization work on Testing of HTS AC cables. However, the individual test method that used to measure a performance of HTS cables hasn’t been established as world’s common methods. The AC loss is one of the most important properties to disseminate low loss and economical efficient HTS cables in the world. We regard to establish the method of the AC loss measurements in rational and in high accuracy. Japan is at a leading position in the AC loss study, because Japanese researchers have studied on the AC loss technically and scientifically, and also developed the effective technologies for the AC loss reduction. The JP domestic commission of TC90 made a working team to discussion the methods of the AC loss measurements for aiming an international standard finally. This paper reports about the AC loss measurement of two type of the HTS conductors, such as a HTS conductor without a HTS shield and a HTS conductor with a HTS shield. The AC loss measurement method is suggested by the electrical method..

  9. Rhodamine-WT dye losses in a mountain stream environment

    Science.gov (United States)

    Bencala, Kenneth E.; Rathburn, Ronald E.; Jackman, Alan P.; Kennedy, Vance C.; Zellweger, Gary W.; Avanzino, Ronald J.

    1983-01-01

    A significant fraction of rhodamine WT dye was lost during a short term multitracer injection experiment in a mountain stream environment. The conservative anion chloride and the sorbing cation lithium were concurrently injected. In-stream rhodamine WT concentrations were as low as 45 percent of that expected, based on chloride data. Concentration data were available from shallow‘wells’dug near the stream course and from a seep of suspected return flow. Both rhodamine WT dye and lithium were nonconservative with respect to the conservative chloride, with rhodamine WT dye closely following the behavior of the sorbing lithium.Nonsorption and sorption mechanisms for rhodamine WT loss in a mountain stream were evaluated in laboratory experiments. Experiments evaluating nonsorption losses indicated minimal losses by such mechanisms. Laboratory experiments using sand and gravel size streambed sediments show an appreciable capacity for rhodamine WT sorption.The detection of tracers in the shallow wells and seep indicates interaction between the stream and the flow in the surrounding subsurface, intergravel water, system. The injected tracers had ample opportunity for intimate contact with materials shown in the laboratory experiments to be potentially sorptive. It is suggested that in the study stream system, interaction with streambed gravel was a significant mechanism for the attenuation of rhodamine WT dye (relative to chloride).

  10. Cytoprotective effects of essential oil of Pinus halepensis L. against aspirin-induced toxicity in IEC-6 cells.

    Science.gov (United States)

    Bouzenna, Hafsia; Hfaiedh, Najla; Bouaziz, Mouhamed; Giroux-Metges, Marie-Agnès; Elfeki, Abdelfattah; Talarmin, Hélène

    2017-12-01

    Essential oils from Pinus species have been reported to have various therapeutic properties. This study was undertaken to identify the chemical composition and cytoprotective effects of the essential oil of Pinus halepensis L. against aspirin-induced damage in cells in vitro. The cytoprotection of the oil against toxicity of aspirin on the small intestine epithelial cells IEC-6 was tested. The obtained results have shown that 35 different compounds were identified. Aspirin induced a decrease in cell viability, and exhibited significant damage to their morphology and an increase in superoxide dismutase (SOD) and catalase (CAT) activities. However, the co-treatment of aspirin with the essential oil of Pinus induced a significant increase in cell viability and a decrease in SOD and CAT activities. Overall, these finding suggest that the essential oil of Pinus halepensis L. has potent cytoprotective effect against aspirin-induced toxicity in IEC-6 cells.

  11. Effects of minor Zr and Sr on as-cast microstructure and mechanical properties of Mg-3Ce-1.2Mn-0.9Sc (wt.%) magnesium alloy

    International Nuclear Information System (INIS)

    Pan Fusheng; Yang Mingbo; Shen Jia; Wu Lu

    2011-01-01

    Research highlights: → Minor Zr and/or Sr additions can effectively refine the grains of the Mg-3Ce-1.2Mn-0.9Sc alloy. → Minor Zr and/or Sr additions can improve the tensile properties of the Mg-3Ce-1.2Mn-0.9Sc alloy. → Minor Zr and/or Sr additions can improve the creep properties of the Mg-3Ce-1.2Mn-0.9Sc alloy. - Abstract: The effects of minor Zr and Sr on the as-cast microstructure and mechanical properties of the Mg-3Ce-1.2Mn-0.9Sc (wt.%) alloy were investigated by using optical and electron microscopies, differential scanning calorimetry (DSC) analysis, and tensile and creep tests. The results indicate that adding minor Zr and/or Sr to the Mg-3Ce-1.2Mn-0.9Sc alloy does not cause an obvious change in the morphology and distribution of the Mg 12 Ce phase. However, the grains of the Zr and/or Sr-containing alloys are effectively refined. Among the Zr and/or Sr-containing alloys, the grains of the alloy with the addition of 0.5 wt.%Zr + 0.1 wt.%Sr are the finest, followed by the alloys with the additions of 0.5 wt.%Zr and 0.1 wt.%Sr, respectively. In addition, small additions of Zr and/or Sr can improve the tensile and creep properties of the Mg-3Ce-1.2Mn-0.9Sc alloy. Among the Zr and/or Sr-containing alloys, the alloy with the addition of 0.5 wt.%Zr + 0.1 wt.%Sr obtains the optimum tensile and creep properties.

  12. Perencanaan dan Implementasi Information Security Management System Menggunakan Framework ISO/IEC 20071

    Directory of Open Access Journals (Sweden)

    Anggi Anugraha Putra

    2016-01-01

    Full Text Available Penerapan tata kelola Teknologi Informasi saat ini sudah menjadi kebutuhan dan tuntutan di setiap instansi penyelenggara pelayanan publik mengingat peran TI yang semakin penting bagi upaya peningkatan kualitas layanan sebagai salah satu realisasi dari tata kelola pemerintahan yang baik (Good Corporate Governance. Dalam penyelenggaraan tata kelola TI, faktor keamanan informasi merupakan aspek yang sangat penting diperhatikan mengingat kinerja tata kelola TI akan terganggu jika informasi sebagai salah satu objek utama tata kelola TI mengalami masalah keamanan informasi yang menyangkut kerahasiaan (confidentiality, keutuhan (integrity dan ketersediaan (availability. Information Security Management System (ISMS adalah seperangkat kebijakan berkaitan dengan manajemen keamanan informasi atau terkait dengan risiko TI. Prinsip yang mengatur di balik ISMS adalah bahwa organisasi harus merancang, menerapkan dan memelihara seperangkat kebijakan, proses dan sistem untuk mengelola risiko aset informasi mereka, sehingga memastikan tingkat risiko keamanan informasi yang dapat diterima. Dari perencanaan dan implementasi sistem manajemen keamanan informasi ini, dihasilkan daftar nilai risiko akhir aset- aset kritikal dan dokumen-dokumen tata kelola penunjang ISMS. Metode penelitian yang digunakan adalah studi kasus yang didalam hal ini, merupakan penelitian kualitatif. Adapun proses yang digunakan untuk mengukur tingkat kematangan dari tata kelola keamanan sistem informasi ini berdasarkan kerangka kerja ISO/IEC 27001. Dari kerangka tersebut kemudian dilakukan evaluasi terhadap objek kontrol yang dimiliki ISO/IEC 27001. Hasil yang didapat adalah peningkatan terhadap tata kelola keamanan sistem informasi. Kesimpulan dari penelitian ini adalah dibutuhkannya tata kelola keamanan sistem informasi agar IT dapat diandalkan untuk mencapai tujuan bisnis.

  13. Comparative study on implementation of management requires from ABNT NBR ISO/IEC 17025

    International Nuclear Information System (INIS)

    Suplino Filho, Carlos Alberto Lucas; Souza, Luciane de Rezende; Oliveira, Estela Maria de

    2014-01-01

    This work was developed in order to emphasize the importance of laboratory management system in the direction and control of the company or institute with regard to the quality of delivery of ionizing radiation service to society. It was developed a comparative study of managerial points of Deming with the managerial requirements of ISO / IEC 17025, which found that the difficulties of the laboratories indicated by nonconformities tracked during audits, are related to specific points cited by Deming. (author)

  14. 7th Annual CMMI Technology Conference and User Group. Volume 1. Tuesday Presentations

    Science.gov (United States)

    2007-11-15

    and models • Harmonization of ISO /IEC 12207 (Standard for Information Technology - Software Life Cycle Processes) & ISO /IEC15288 Ø ODUSD(A&T) Systems...15288: SE-System Life Cycle Processes ISO /IEC 12207 : Standard for IT-Software life cycle processes [also Industry Implementation via IEEE/EIA] IEEE...15288 (04) INCOSE SE HB v3.1 (07) ISO /IEC 15288( 07) IEEE/EIA 12207 (97) reaffirmed@ GEIA [03] ISO /IEC 12207 (95) ISO /IEC 12207 07) SE standards

  15. Pembuatan Tata Kelola Keamanan Informasi Kontrol Akses Berbasis ISO/IEC 27001:2005 Pada Kantor Pelayanan Perbendaharaan Surabaya I

    Directory of Open Access Journals (Sweden)

    Margo Utomo

    2012-09-01

    Full Text Available Perkembangan teknologi informasi yang pesat saat ini turut berimbas kepada penggunaan teknologi informasi di lingkungan pemerintahan. KPPN Surabaya I sebagai instansi vertikal dari Direktorat Jenderal Perbendaharaan juga menerapkan teknologi informasi dalam untuk mendukung kegiatan pelayanan terhadap satuan kerja yang berada di lingkup bayarnya. Sayangnya masalah keamanan informasi yang merupakan bagian penting dari teknologi informasi sering kali kurang mendapatkan perhatian. Tidak dapat dipungkiri bahwa munculnya ancaman ataupun kelemahan dalam teknologi informasi dapat menggangu jalannya kegiatan pelayanan yang menggunakan teknologi informasi. Oleh karena itu diperlukan pengelolaan teknologi informasi berbasis risiko yang dituangkan dalam tata kelola untuk mengelola ancaman ataupun kelemahan yang muncul. ISO/IEC 27001:2005 merupakan framework sistem manajemen keamanan informasi yang dapat dijadikan dasar dalam pengelolaan keamanan informasi. Tata kelola keamanan informasi yang dibuat ini menitikberatkan pada kontrol akses yang merupakan salah satu kotrol keamanan dari ISO/IEC 27001:2005

  16. FY 1999 Report on the technical results. Research and development project for creation of the quick-effect type international standards (Standardization in the field of safety of machinery); 1999 nendo sokkogata kokusai hyojun sosei kenkyu kaihatsu jigyo seika hokokusho. Kikai anzensei ni kakawaru hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    It is necessary to standardize the concepts and terminology of safety, design principles, protection and technology for evaluation of safety over a wide range including designs and specifications, in order to secure safety of the users. The international standardization has been promoted, based on the European voluntary standards EN. It is necessary for Japan to propose the international standards reflecting the industrial environments of Japan, in order to keep and expand her international competitiveness. Those technologies developed for the above purposes include the safety-related ones based on the Japanese electronic technologies, electronized operation-controlling technologies with dynamic fail safe signal processing, DC power supply circuit with a failure-sensing circuit, opto-ultrasonic hybrid type personal sensing device and pressure-sensitive mat sensor, emergency stop devices having no electrical contact to eliminate the contact fusing risk, and video camera system which facilitates emergency stop action of machinery. These results are submitted to the related technical committees of ISO or IEC. A total of 46 items of the international standard proposal drafts related to IEC/TC44 are also submitted. (NEDO)

  17. International laser safety standardization. From the European perspective with an emphasis on materials processing

    Energy Technology Data Exchange (ETDEWEB)

    Schulmeister, K [Div. of Life Sciences, Dept. of Radiation Protection, Oesterreichisches Forschungszentrum Seibersdorf, 2444 Seibersdorf (Austria)

    1997-08-01

    This report reviews international standards relevant to the safety of laser products and laser installations, with an emphasis on the safety of laser materials processing from the European perspective. In the first paragraphs an overview of the international standards organisations, their relative roles and ways of developing new standards is given. In the second part of the report, work currently underway in the respective standards committees is summarised and specific standards dealing with different aspects of laser safety are discussed. An appendix contains a list of standards organised in standards organisations (IEC, ISO and EN). (author)

  18. International laser safety standardization. From the European perspective with an emphasis on materials processing

    International Nuclear Information System (INIS)

    Schulmeister, K.

    1997-08-01

    This report reviews international standards relevant to the safety of laser products and laser installations, with an emphasis on the safety of laser materials processing from the European perspective. In the first paragraphs an overview of the international standards organisations, their relative roles and ways of developing new standards is given. In the second part of the report, work currently underway in the respective standards committees is summarised and specific standards dealing with different aspects of laser safety are discussed. An appendix contains a list of standards organised in standards organisations IEC, ISO and EN). (author)

  19. NC ISO/IEC1725:00 Accreditation process of CPHR main laboratories

    International Nuclear Information System (INIS)

    Marrero Garcia, Mariela; Molina perez, Daniel; Fernandez Gomez, Maria; Walwyn Salas, Gonzalo

    2003-01-01

    With the objective of offering technically qualified and competitive services one works in our laboratories under the requirements of a System of the Quality from 1993. In 1999 that was already with a draft of the new model ISO/IEC 17025:00 the steps they were given for the change of the Guide 25. At the moment with 3 laboratories accredited by the Cuban organ (ONARC), we are pioneer in these changes because alone a very reduced group of laboratories in the country has achieved it. The present work enunciates the antecedents of the change, the main non conformities during the evaluations for the accreditation and the obtained results

  20. WT1 isoform expression pattern in acute myeloid leukemia.

    Science.gov (United States)

    Luna, Irene; Such, Esperanza; Cervera, Jose; Barragán, Eva; Ibañez, Mariam; Gómez-Seguí, Inés; López-Pavía, María; Llop, Marta; Fuster, Oscar; Dolz, Sandra; Oltra, Silvestre; Alonso, Carmen; Vera, Belén; Lorenzo, Ignacio; Martínez-Cuadrón, David; Montesinos, Pau; Senent, M Leonor; Moscardó, Federico; Bolufer, Pascual; Sanz, Miguel A

    2013-12-01

    WT1 plays a dual role in leukemia development, probably due to an imbalance in the expression of the 4 main WT1 isoforms. We quantify their expression and evaluate them in a series of AML patients. Our data showed a predominant expression of isoform D in AML, although in a lower quantity than in normal CD34+ cells. We found a positive correlation between the total WT1 expression and A, B and C isoforms. The overexpression of WT1 in AML might be due to a relative increase in A, B and C isoforms, together with a relative decrease in isoform D expression. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Characterization of an active dosemeter according to IEC 61526:2010

    International Nuclear Information System (INIS)

    Cardoso, J.; Santos, L.; Santos, J.A.M.; Alves, J.G.; Oliveira, C.

    2016-01-01

    The active personal dosemeter, RaySafe i2, allows the measurement and record of Hp(10) in real time, every second, via wireless technology for real-time display on a portable computer and/or a local network. The system seems particularly attractive for individual monitoring at clinical facilities where high intensity and varying radiation fields may occur, as it enables the user to acknowledge and optimize the dose and dose rate values in real time for each procedure. Prior to its use, the system was characterized at the Metrology Laboratory of Ionizing Radiation of IST-LPSR aiming at the metrological characterization of the system in accordance with IEC 61526:2010 for metrological control purposes and to verify the technical specifications stated by the manufacturer. (authors)

  2. Structures of native and affinity-enhanced WT1 epitopes bound to HLA-A*0201: Implications for WT1-based cancer therapeutics

    Energy Technology Data Exchange (ETDEWEB)

    Borbulevych, Oleg Y.; Do, Priscilla; Baker, Brian M. (Notre)

    2010-09-07

    Presentation of peptides by class I or class II major histocompatibility complex (MHC) molecules is required for the initiation and propagation of a T cell-mediated immune response. Peptides from the Wilms Tumor 1 transcription factor (WT1), upregulated in many hematopoetic and solid tumors, can be recognized by T cells and numerous efforts are underway to engineer WT1-based cancer vaccines. Here we determined the structures of the class I MHC molecule HLA-A*0201 bound to the native 126-134 epitope of the WT1 peptide and a recently described variant (R1Y) with improved MHC binding. The R1Y variant, a potential vaccine candidate, alters the positions of MHC charged side chains near the peptide N-terminus and significantly reduces the peptide/MHC electrostatic surface potential. These alterations indicate that the R1Y variant is an imperfect mimic of the native WT1 peptide, and suggest caution in its use as a therapeutic vaccine. Stability measurements revealed how the R1Y substitution enhances MHC binding affinity, and together with the structures suggest a strategy for engineering WT1 variants with improved MHC binding that retain the structural features of the native peptide/MHC complex.

  3. Software validation applied to spreadsheets used in laboratories working under ISO/IEC 17025

    Science.gov (United States)

    Banegas, J. M.; Orué, M. W.

    2016-07-01

    Several documents deal with software validation. Nevertheless, more are too complex to be applied to validate spreadsheets - surely the most used software in laboratories working under ISO/IEC 17025. The method proposed in this work is intended to be directly applied to validate spreadsheets. It includes a systematic way to document requirements, operational aspects regarding to validation, and a simple method to keep records of validation results and modifications history. This method is actually being used in an accredited calibration laboratory, showing to be practical and efficient.

  4. Energy Efficiency Standards of Induction Motors, ¿Are you Prepared Latin America?

    Directory of Open Access Journals (Sweden)

    Carlos M. Londoño-Parra

    2013-06-01

    Full Text Available In Colombia the regulatory process regarding the energy efficiency of end-use prod-ucts is emerging with the draft technical regulation product labeling RETIQ, which includes in Annex E, the test methods for determining the efficiency of motors alternat-ing current induction. The goal of this paper is to compare the energy efficiency of induction motors between the countries of Latin America and the countries of the major economies of the globe, considering four aspects: the current state of classification standards and test procedures of induction motors efficiency, multilateral agreements of mutual recognition, the infrastructure to conduct tests of the standard and support programs to improve the efficiency of electric motor-driven systems. The study reveals that Latin America is a considerable delay in the implementation of classification standards and methods for testing the efficiency of electric motors, most widely used in the world: IEC 60034-30:2008, IEC 60034-2-1: 2007 IEEE 112:2004 and EPAct'92, with respect to the countries of the European Union, United States, China, Australia, and other developed countries, in which these standards have been adopted. Furthermore, the region is evident in the absence of programs focused on improving the energy efficiency of electric motors and a limited number of accredited laboratories to evaluate their efficiency, which leads to most Latin American countries to establish agreements mutual recognition for this purpose.

  5. Energy Efficiency Standards of Induction Motors, ¿Are you Prepared Latin America?

    Directory of Open Access Journals (Sweden)

    Carlos M. Londoño-Parra

    2013-06-01

    Full Text Available In Colombia the regulatory process regarding the energy efficiency of end-use products is emerging with the draft technical regulation product labeling RETIQ, which includes in Annex E, the test methods for determining the efficiency of motors alternating current induction. The goal of this paper is to compare the energy efficiency of induction motors between the countries of Latin America and the countries of the major economies of the globe, considering four aspects: the current state of classification standards and test procedures of induction motors efficiency, multilateral agreements of mutual recognition, the infrastructure to conduct tests of the standard and support programs to improve the efficiency of electric motor-driven systems. The study reveals that Latin America is a considerable delay in the implementation of classification standards and methods for testing the efficiency of electric motors, most widely used in the world: IEC 60034-30:2008, IEC 60034-2-1: 2007 IEEE 112:2004 and EPAct'92, with respect to the countries of the European Union, United States, China, Australia, and other developed countries, in which these standards have been adopted. Furthermore, the region is evident in the absence of programs focused on improving the energy efficiency of electric motors and a limited number of accredited laboratories to evaluate their efficiency, which leads to most Latin American countries to establish agreements mutual recognition for this purpose.

  6. EASIER ACCESS TO STANDARDS DOCUMENTATION

    CERN Multimedia

    2001-01-01

    Many organizations issuing standards offer reduced prices for publications to their members. Paying a membership fee, even a site membership fee, can therefore be worthwhile - even if relatively few standards are needed. The Library is now exploring the possibility, in collaboration with the rest of the CERN community, of joining standards-issuing organizations. So why not share your costs with the rest of the organization wherever this can be done without violating copyright or access regulations? The Library now provides documentation and other member services from IPC, the Association Connecting Electronics Industries (http://www.ipc.org/html/fsabout.htm) at favourable prices for the entire CERN population. For more information, or if you are a member of any other organization which provides services which could be shared CERN-wide, please contact library.desk@cern.ch . We remind all users of international standards, that CERN has special agreements with ISO and IEC (see Bulletin 50/2000). You can order st...

  7. Electron emitter pulsed-type cylindrical IEC

    International Nuclear Information System (INIS)

    Miley, G.H.; Gu, Y.; Stubbers, R.; Zich, R.; Anderl, R.; Hartwell, J.

    1997-01-01

    A cylindrical version of the single grid Inertial Electrostatic Confinement (IEC) device (termed the C-device) has been developed for use as a 2.5-MeV D-D fusion neutron source for neutron activation analysis. The C-device employs a hollow-tube type cathode with similar anodes backed up by ''reflector'' dishes. The resulting discharge differs from a conventional hollow cathode discharge, by creating an explicit ion beam which is ''pinched'' in the cathode region. Resulting fusion reactions generate ∼10 6 neutron/s. A pulsed version is under development for applications requiring higher fluxes. Several pulsing techniques are under study, including an electron emitter (e-emitter) assisted discharge in a thorated tungsten wire emitter located behind a slotted area in the reflector dishes. Pulsing is initiated after establishing a low power steady-state discharge by pulsing the e-emitter current using a capacitor switch type circuit. The resulting electron jet, coupled with the discharge by the biased slot array, creates a strong pulse in the pinched ion beam. The pulse length/repetition rate are controlled by the e-emitter pulse circuit. Typical parameters in present studies are ∼30micros, 10Hz and 1-amp ion current. Corresponding neutron measurements are an In-foil type activation counter for time averaged rates. Results for a wide variety of operating conditions are presented

  8. A methodology for distinguishing divergent cell fates within a common progenitor population: adenoma- and neuroendocrine-like cells are confounders of rat ileal epithelial cell (IEC-18 culture

    Directory of Open Access Journals (Sweden)

    Paxton Jessica B

    2005-01-01

    Full Text Available Abstract Background IEC-18 cells are a non-transformed, immortal cell line derived from juvenile rat ileal crypt cells. They may have experimental advantages over tumor-derived gastrointestinal lineages, including preservation of phenotype, normal endocrine responses and retention of differentiation potential. However, their proclivity for spontaneous differentiation / transformation may be stereotypical and could represent a more profound experimental confounder than previously realized. We hypothesized that IEC-18 cells spontaneously diverge towards a uniform mixture of epigenetic fates, with corresponding phenotypes, rather than persist as a single progenitor lineage. Results IEC-18 cells were cultured for 72 hours in serum free media (SFM, with and without various insulin-like growth factor agonists to differentially boost the basal rate of proliferation. A strategy was employed to identify constitutive genes as markers of divergent fates through gene array analysis by cross-referencing fold-change trends for individual genes against crypt cell abundance in each treatment. We then confirmed the cell-specific phenotype by immunolocalization of proteins corresponding to those genes. The majority of IEC-18 cells in SFM alone had a loss in expression of the adenomatous polyposis coli (APC gene at the mRNA and protein levels, consistent with adenoma-like transformation. In addition, a small subset of cells expressed the serotonin receptor 2A gene and had neuroendocrine-like morphology. Conclusions IEC-18 cells commonly undergo a change in cell fate prior to reaching confluence. The most common fate switch that we were able to detect correlates with a down regulation of the APC gene and transformation into an adenoma-like phenotype.

  9. Network Authentication Protocol Studies

    Science.gov (United States)

    2009-04-01

    usually require compliance with development standards such as ISO 12207 or IEEE / IEC 12207 . Those standards mandate traceability as a property of a...standards have been proposed to deal with non-repudiation. ISO /IEC 10181-4 [19] and ISO /IEC 13888 [20, 22, 21]. While ISO /IEC 10181-4 provides a...framework for developing and employing these services, ISO /IEC 13888 consists of three parts. They propose a general model of non-repudiation and a set of

  10. Preparation and characterization of PVA/SSA membranes with Al{sub 2}O{sub 3} nanoparticles for fuel cell applications; Preparacao de caracterizacao de membranas de PVAL/SSA na presenca de nanoparticulas de Al{sub 2}O{sub 3} para aplicacao em celulas de combustivel

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Paula N.; Pires, Alfredo T.N. [Grupo de Estudo em Materiais Polimericos - POLIMAT - UFSC, Florianopolis, SC (Brazil); Catarino, Margarida; Brandao, Lucia; Tanaka, Alfredo; Mendes, Adelio [Faculdade de Engenharia da Universidade do Porto, Porto (Portugal)

    2011-07-01

    In the present study, PVA/SSA membranes were prepared with and without the addition of Al{sub 2}O{sub 3} nanoparticles. Sulfosuccinic acid (SSA) was used as the crosslinking agent. Membranes were prepared with different amounts of SSA (26, 43 and 55 wt.%) and with 5 and 10 wt.% of nanoparticles. Crosslinking was performed at 90 degree C during 1.5 h. Membranes were analyzed by infrared spectroscopy, thermal analysis, water absorption, ion exchange capacity (IEC) and proton conductivity. The results showed that control of the crosslinking conditions, IEC value, water absorption and polymer structure are of significant importance to obtain a set of properties suitable for application in proton exchange membrane fuel cells. (author)

  11. 75 FR 81789 - Third Party Testing for Certain Children's Products; Full-Size Baby Cribs and Non-Full-Size Baby...

    Science.gov (United States)

    2010-12-28

    ... Standardization (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the... accreditation must be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing...

  12. Phase development in a U-7 wt.% Mo vs. Al-7 wt.% Ge diffusion couple

    Science.gov (United States)

    Perez, E.; Keiser, D. D.; Sohn, Y. H.

    2013-10-01

    Fuel development for the Reduced Enrichment for Research and Test Reactors (RERTR) program has demonstrated that U-Mo alloys in contact with Al develop interaction regions with phases that have poor irradiation behavior. The addition of Si to the Al has been considered with positive results. In this study, compositional modification is considered by replacing Si with Ge to determine the effect on the phase development in the system. The microstructural and phase development of a diffusion couple of U-7 wt.% Mo in contact with Al-7 wt.% Ge was examined by transmission electron microscopy, scanning electron microscopy and energy dispersive spectroscopy. The interdiffusion zone developed a microstructure that included the cubic-UGe3 phase and amorphous phases. The UGe3 phase was observed with and without Mo and Al solid solution developing a (U,Mo)(Al,Ge)3 phase.

  13. Zero-correlation linear cryptanalysis with FFT and improved attacks on ISO standards Camellia and CLEFIA

    DEFF Research Database (Denmark)

    Bogdanov, Andrey; Geng, Huizheng; Wang, Meiqin

    2014-01-01

    as published in FSE'12 and ASIACRYPT'12, respectively. In this paper, we use the FFT (Fast Fourier Transform) technique to speed up the zero-correlation cryptanalysis. First, this allows us to improve upon the state-of-the-art cryptanalysis for the ISO/IEC standard and CRYPTREC-portfolio cipher Camellia...

  14. Viscous behavior of (Sn{sub 61.9}Pb{sub 38.1}){sub 100-x}RE{sub x} (x=0, 0.1, 0.3, 1 wt%) solder alloys

    Energy Technology Data Exchange (ETDEWEB)

    Wu Yuqin [Key Laboratory of Liquid Structure and Heredity of Materials, Ministry of Education, Shandong University (Southern Campus), 73 Jingshi Road, Jinan 250061 (China); Bian Xiufang [Key Laboratory of Liquid Structure and Heredity of Materials, Ministry of Education, Shandong University (Southern Campus), 73 Jingshi Road, Jinan 250061 (China)], E-mail: xfbian@sdu.edu.cn; Zhao Yan; Li Xuelian; Zhang Yanning; Tian Yongsheng; Lv Xiaoqian [Key Laboratory of Liquid Structure and Heredity of Materials, Ministry of Education, Shandong University (Southern Campus), 73 Jingshi Road, Jinan 250061 (China)

    2008-05-19

    The viscous behavior of (Sn{sub 61.9}Pb{sub 38.1}){sub 100-x}RE{sub x} (x=0, 0.1, 0.3, 1 wt%) solder alloys has been investigated by a torsional oscillation viscometer. The structural transition temperature T{sup '} increases with increasing addition of RE elements. Above T{sup '}, the viscosities of melts increase with increasing addition of RE, and are fitted well with the Arrhenius equation. The time dependence of viscosity at the measured temperature below T{sup '} follows the exponential relaxation function and reflects the process of the structural transition in the melt, which can be considered as the thermodynamic equilibrium process. The thermodynamic equilibrium relaxation time {tau}{sub eq} increases with both the equilibrium viscosity {eta}{sub eq} and the discrepancy in viscosity ({delta}{eta}), between the initial state and the equilibrium state. However, it decreases with the measured temperature T. The size of clusters in the melts increases with increasing of viscosity and is restricted by the thermodynamic equilibrium conditions.

  15. Fiscal 2000 project for development of international standards for supporting novel industries. Standardization of methods for testing and evaluating plastic optical fiber; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Plastic hikari fiber no shiken hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Studies were made about methods for testing and evaluating plastic optical fiber (POF) for the purpose of submitting a proposition to IEC (International Electrotechnical Commission) for the methods to be internationally standardized. In this fiscal year, tests and analyses were conducted relative to the effects of the light source emission area size, wavelength, and axial displacement. Next, underfilled launch was studied from a practical viewpoint, and a method using a mode filter was proposed. Finally, round robin tests were conducted for each of the companies using overfilled launch and underfilled launch, and the reproducibility of measured values was grasped. In this fiscal year, a new study added, which involved a method for measuring structural parameters. Though POF was below standard as an object of IEC's gray scale method, yet it was found, thanks to the recently developed CCD (charge coupled device) cameras, that the method might also be applicable to POF. A groundwork plan was drafted on band test methods including the overfilled launch method toward international standardization. (NEDO)

  16. Osr1 Interacts Synergistically with Wt1 to Regulate Kidney Organogenesis.

    Directory of Open Access Journals (Sweden)

    Jingyue Xu

    Full Text Available Renal hypoplasia is a common cause of pediatric renal failure and several adult-onset diseases. Recent studies have associated a variant of the OSR1 gene with reduction of newborn kidney size and function in heterozygotes and neonatal lethality with kidney defects in homozygotes. How OSR1 regulates kidney development and nephron endowment is not well understood, however. In this study, by using the recently developed CRISPR genome editing technology, we genetically labeled the endogenous Osr1 protein and show that Osr1 interacts with Wt1 in the developing kidney. Whereas mice heterozygous for either an Osr1 or Wt1 null allele have normal kidneys at birth, most mice heterozygous for both Osr1 and Wt1 exhibit defects in metanephric kidney development, including unilateral or bilateral kidney agenesis or hypoplasia. The developmental defects in the Osr1+/-Wt1+/- mouse embryos were detected as early as E10.5, during specification of the metanephric mesenchyme, with the Osr1+/-Wt1+/- mouse embryos exhibiting significantly reduced Pax2-positive and Six2-positive nephron progenitor cells. Moreover, expression of Gdnf, the major nephrogenic signal for inducing ureteric bud outgrowth, was significantly reduced in the metanephric mesenchyme in Osr1+/-Wt1+/- embryos in comparison with the Osr1+/- or Wt1+/- littermates. By E11.5, as the ureteric buds invade the metanephric mesenchyme and initiate branching morphogenesis, kidney morphogenesis was significantly impaired in the Osr1+/-Wt1+/- embryos in comparison with the Osr1+/- or Wt1+/- embryos. These results indicate that Osr1 and Wt1 act synergistically to regulate nephron endowment by controlling metanephric mesenchyme specification during early nephrogenesis.

  17. Functional Suitability Measurement using Goal-Oriented Approach based on ISO/IEC 25010 for Academics Information System

    Directory of Open Access Journals (Sweden)

    Ajeng Savitri Puspaningrum

    2017-10-01

    Full Text Available Rapid of information technology development grow a new competitive environment. Including higher education, they need to improve their service quality in order to provide education service in more competitive. One of the ways of using information technology in higher education is the used of Academic Information System (AIS. AIS was developed to achieve the goals of the learning process which is one of vision and mission organization success factor. The measurement is needed to evaluate the quality of AIS. Functionality is one of the quality factors which is measured by observing the correlation between function and functional suitability. In this study, the quality of AIS functional suitability is measured using goal-oriented approach base on ISO/IEC 25010 in the perspective of a lecturer. The strategic plan of an institution is used as a reference to measure if the system used to have meet institution goals when using this approach. The result shows that the measurement using goal-oriented approach become more objective and suitable to the need of used AIS quality improvement for the institution than the measurement with ISO/IEC 25010 only.

  18. Establishment of a primary standard system for low energy X-rays using a free air ionization chamber

    International Nuclear Information System (INIS)

    Silva, Natalia Fiorini da

    2016-01-01

    In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was ma de. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI. (author)

  19. Phase development in a U–7 wt.% Mo vs. Al–7 wt.% Ge diffusion couple

    Energy Technology Data Exchange (ETDEWEB)

    Perez, E., E-mail: Emmanuel.Perez@inl.gov [Nuclear Fuels and Materials Development, Idaho National Laboratory, Box 1625, Idaho Falls, ID 83415 (United States); Keiser, D.D. [Nuclear Fuels and Materials Development, Idaho National Laboratory, Box 1625, Idaho Falls, ID 83415 (United States); Sohn, Y.H. [Advanced Materials Processing and Analysis Center, and Department of Materials Science and Engineering, University of Central Florida, 4000 Central Florida Blvd., Orlando, FL 32816 (United States)

    2013-10-15

    Fuel development for the Reduced Enrichment for Research and Test Reactors (RERTR) program has demonstrated that U–Mo alloys in contact with Al develop interaction regions with phases that have poor irradiation behavior. The addition of Si to the Al has been considered with positive results. In this study, compositional modification is considered by replacing Si with Ge to determine the effect on the phase development in the system. The microstructural and phase development of a diffusion couple of U–7 wt.% Mo in contact with Al–7 wt.% Ge was examined by transmission electron microscopy, scanning electron microscopy and energy dispersive spectroscopy. The interdiffusion zone developed a microstructure that included the cubic-UGe{sub 3} phase and amorphous phases. The UGe{sub 3} phase was observed with and without Mo and Al solid solution developing a (U,Mo)(Al,Ge){sub 3} phase.

  20. 75 FR 42315 - Third Party Testing for Certain Children's Products; Carpets and Rugs: Requirements for...

    Science.gov (United States)

    2010-07-21

    ... (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements for... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the....org/membersbycategory.html . The accreditation must be to ISO Standard ISO/IEC 17025:2005, ``General...

  1. On the long-term stability of calibration standards in different matrices

    International Nuclear Information System (INIS)

    Kandić, A.; Vukanac, I.; Djurašević, M.; Novković, D.; Šešlak, B.; Milošević, Z.

    2012-01-01

    In order to assure Quality Control in accordance with ISO/IEC 17025, it was important, from metrological point of view, to examine the long-term stability of calibration standards previously prepared. Comprehensive reconsideration on efficiency curves with respect to the ageing of calibration standards is presented in this paper. The calibration standards were re-used after a period of 5 years and analysis of the results showed discrepancies in efficiency values. - Highlights: ► Long-term stability of calibration standards (ISO 17025 Quality Control) was analyzed. ► Calibration standards covered the wide range of densities and chemical composition. ► Mineralized grass, powdered milk, surface soil and sand were used as standard matrices. ► Calibration standards were re-evaluated after 5 years. ► Results showed discrepancies of efficiency values.

  2. Analysis of aquifer tests conducted in boreholes USW WT-10, UE-25 WT No. 12, and USW SD-7, 1995-96, Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    O'Brien, G.M.

    1997-01-01

    Single-borehole aquifer tests were conducted in three boreholes in the Yucca Mountain area between March 1995 and January 1996 to obtain estimates of borehole specific capacity and aquifer transmissivity. Analysis of aquifer testing in borehole USW SD-7 also resulted in an estimate of reservoir volume. Aquifer-test data were analyzed with the Cooper and Jacob straight-line method, two modified Theis nonequilibrium equation solutions, and a modified reservoir-limit solution. The highest estimates of transmissivity were in borehole USW WT-10, completed in the Topopah Spring Tuff. Mean transmissivity, based on the results of three drawdown tests, was 1,600 meters squared per day. Mean specific capacity in borehole USW WT-10 after 5 hours of pumping was 1,100 meters squared per day, and was estimated to be 740 meters squared per day after 24 hours of pumping. Aquifer testing in borehole UE-25 WT No. 12 appeared to be significantly affected by well losses. A mean transmissivity of 7 meters squared per day was obtained on the basis of analysis of three drawdown tests in borehole UE-25 WT No. 12. Mean specific capacity in borehole UE-25 WT No. 12, after 24 hours of pumping, was 7 meters squared per day. Borehole UE-25 WT No. 12 seemed to be producing water from fractures that could provide only a limited amount of water to the borehole

  3. Introducción al modelo Topic Maps (ISO/IEC13250:2003

    Directory of Open Access Journals (Sweden)

    Maria Jesús Colmenero Ruiz

    2005-07-01

    Full Text Available Se realiza una revisión del estándar ISO/IEC 13250:2003 Topic Maps, resaltando sus posibilidades en el ámbito documental. Tras describir su evolución histórica y la situación actual se desarrollan los conceptos que componen este modelo, los tres elementos básicos (topic, association, y occurrence y dos más (scope y public subject, analizando sus posibilidades para la organización del conocimiento, como estructura de navegación semántica y para la interoperabilidad. Se analizan los elementos más interesantes de la especificación XTM 1.0 y, por último, se detallan algunos de los entornos en los que está siendo aplicado.

  4. 75 FR 22746 - Third Party Testing for Certain Children's Products; Notice of Requirements for Accreditation of...

    Science.gov (United States)

    2010-04-30

    ... (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements for... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the.../membersbycategory.html . The accreditation must be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for...

  5. 78 FR 37760 - Electrical Equipment in Hazardous Locations

    Science.gov (United States)

    2013-06-24

    ... Standardization ISO/IEC Standard 17025 and related IECEx procedures. The ExTL tests the subject equipment and...)/IEC Standard 17025 and related IECEx Operational Documents and Rules of Procedure. Some foreign flag... internationally accepted independent third-party certification system, the IEC System for Certification to...

  6. 75 FR 51016 - Third Party Testing for Certain Children's Products; Clothing Textiles: Requirements for...

    Science.gov (United States)

    2010-08-18

    ... (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements for... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the... must be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and...

  7. Effect of Ag additions on the β phase formation reaction in the Cu–9 wt.%Al–6 wt.%Mn alloy

    Energy Technology Data Exchange (ETDEWEB)

    Adorno, A.T., E-mail: atadorno@iq.unesp.br [Departamento de Físico-Química, Instituto de Química, UNESP, Caixa Postal 355, 14801-970 Araraquara, SP (Brazil); Carvalho, T.M. [Departamento de Físico-Química, Instituto de Química, UNESP, Caixa Postal 355, 14801-970 Araraquara, SP (Brazil); Silva, R.A.G. [Departamento de Ciências Exatas e da Terra, UNIFESP, 09972-270 Diadema, SP (Brazil); Santos, C.M.A.; Magdalena, A.G. [Departamento de Físico-Química, Instituto de Química, UNESP, Caixa Postal 355, 14801-970 Araraquara, SP (Brazil)

    2015-09-15

    Highlights: • The results suggest a multi-step process involving reversible reactions. • Ag solubilizes preferably at the Cu matrix. • Ag additions decrease the activation energy for the process. - Abstract: The influence of 4 and 5 wt.%Ag additions on the kinetics of β [T{sub 7}-(CuMn){sub 3}Al] phase formation reaction in the Cu–9 wt.%Al–6 wt.%Mn alloy was studied using differential scanning calorimetry (DSC), X-ray diffractometry (XRD) and scanning electron microscopy (SEM). The results indicate that the conversion dependence of the activation energy has a descending shape, suggesting a multi-step process involving reversible reactions. The presence of Ag facilitates the formation of the β phase. The results also showed that the Ag precipitates formation includes the dissolution of Mn and Al atoms, thus decreasing the partial fraction of these elements available to react.

  8. A Model for Joint Software Reviews

    Science.gov (United States)

    1998-10-01

    CEPMAN 1, 1996; Gabb, 1997], and with the growing popularity of outsourcing, they are becoming more important in the commercial sector [ ISO /IEC 12207 ...technical and management reviews [MIL-STD-498, 1996; ISO /IEC 12207 , 1995]. Management reviews occur after technical reviews, and are focused on the cost...characteristics, Standard (No. ISO /IEC 9126-1). [ ISO /IEC 12207 , 1995] Information Technology Software Life Cycle Processes, Standard (No. ISO /IEC 12207

  9. Validation of an indirect ELISA to detect antibodies against BoHV-1 in bovine and guinea-pig serum samples using ISO/IEC 17025 standards.

    Science.gov (United States)

    Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando

    2010-10-01

    Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  10. Integrating RAMS engineering and management with the safety life cycle of IEC 61508

    International Nuclear Information System (INIS)

    Lundteigen, Mary Ann; Rausand, Marvin; Utne, Ingrid Bouwer

    2009-01-01

    This article outlines a new approach to reliability, availability, maintainability, and safety (RAMS) engineering and management. The new approach covers all phases of the new product development process and is aimed at producers of complex products like safety instrumented systems (SIS). The article discusses main RAMS requirements to a SIS and presents these requirements in a holistic perspective. The approach is based on a new life cycle model for product development and integrates this model into the safety life cycle of IEC 61508. A high integrity pressure protection system (HIPPS) for an offshore oil and gas application is used to illustrate the approach.

  11. Implementing healthcare information security: standards can help.

    Science.gov (United States)

    Orel, Andrej; Bernik, Igor

    2013-01-01

    Using widely spread common approaches to systems security in health dedicated controlled environments, a level of awareness, confidence and acceptance of relevant standardisation is evaluated. Patients' information is sensitive, so putting appropriate organisational techniques as well as modern technology in place to secure health information is of paramount importance. Mobile devices are becoming the top priorities in advanced information security planning with healthcare environments being no exception. There are less and less application areas in healthcare without having a need for a mobile functionality which represents an even greater information security challenge. This is also true in emergency treatments, rehabilitation and homecare just to mention a few areas outside hospital controlled environments. Unfortunately quite often traditional unsecured communications principles are still in routine use for communicating sensitive health related information. The security awareness level with users, patients and care professionals is not high enough so potential threats and risks may not be addressed and the respective information security management is therefore weak. Standards like ISO/IEC 27000 ISMS family, the ISO/IEC 27799 information security guidelines in health are often not well known, but together with legislation principles such as HIPAA, they can help.

  12. Convergence Analysis of ISO/IEC 12207 and CMMI-DEV: Complementary Result from Systematic Literature Review

    OpenAIRE

    Javier Crisóstomo; Karin Melendez; Luis Flores; Abraham Dávila

    2017-01-01

    The organizations and people are demanding more and better software products and services, which implies adequate processes for its development. In the context of the software industry, there are two models, the CMMI-DEV and ISO/IEC 12207 that are influencing it. Though, they are evolving separately, recurrently they have been compared to determine its coverage (in both directions). In this study is analyzed the results of those comparisons (partials and completed) to determine if the models ...

  13. Safety standards for wind turbines; Sicherheitsnormen fuer Windenergieanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, K. [Underwriters Laboratories Inc., Northbrook, IL (United States)

    2012-08-15

    As the global wind infrastructure sustains rapid growth, compliance with relevant standards provide validation of design principles and establish due diligence in addressing critical attributes such as safety. The IEC 61400 series of standards provides important information for addressing safety and performance of wind turbine systems. Efforts to address unique issues within the United States market has led to development of two safety standards, UL 6141 for large wind turbines and UL 6142 for small wind turbines. These standards, which are being published as American National Standards, contain key safety requirements for the electrical system, electrical safety and controls system, grid connection, and related safety issues. In the future, collaborative efforts will lead to continued exchange of best practices and opportunities for broader harmonization. Development of these standards, and their use by the manufacturing community in design and development of wind turbine products, supports maximal safety and performance of the burgeoning wind infrastructure. (orig.)

  14. The actual problems of the standardization of magnetically hard materials and permanent magnets

    International Nuclear Information System (INIS)

    Kurbatov, P.A.; Podolskiy, I.D.

    1998-01-01

    The standardization of industrial products raises their accordance with functional purpose, contributes to technological developments and the elimination of technical barriers in trade. The progress of the world trade necessitates the certification of permanent magnets and their manufacturing methods. According to ISO/IEC recommendations, the certification standards should contain the clear requirements to operation parameters of products, that can be impartially controlled. The testing procedures should be clearly formulated and assure that the results may be reproduced. This calls for creation of a system of interconnected certification standards: the standard for technical characteristics of prospective commercial magnetically hard materials, the standard specifications for permanent magnets, the standards for typical testing procedures and the standards for metrological assurance of measurements. (orig.)

  15. The control of documents maintained in the electronic media and the requirements of NBR ISO/IEC 17025 and adequacy for PNQ

    Directory of Open Access Journals (Sweden)

    Anselmo Ferreira de Castro

    2006-01-01

    Full Text Available During the assessments carried out by the authors at the diverse laboratories pertaining to the network of accredited laboratories - known as the Brazilian Calibration Network (RBC - the authors verified the difficulties that these laboratories had in meeting the requirements of NBR ISO/IEC 17025:2001 (Standard, related to the maintenance of documents in the electronic media. More and more laboratories are substituting traditional control with electronic document control, which allows for more agility in the recovery of information. These laboratories implement policies and procedures; however, they still feel insecure, in some way, as to how to meet all of these requirements, thereby giving rise to difficulties in the implementation of such. The aim of this paper is to discuss the control of documents stored in the electronic media, adopting requirement 4.3 of the Standard as the reference, and aiming, in this manner, to harmonize the assessment process of the procedures of document management in the electronic media, and to assist the laboratories in the interpretation of the Standard, so that they may implement systems that are adequate to their actual necessities and to their structural size, while at the same time complying with the referred to requirement. This work will not broach the treatment given to the records (requirement 4.12 of the Standard, facts (requirement 5.4.7 nor to the electronic transmission of results (requirement 5.10.7, leaving these subjects for posterior discussions.

  16. Air kerma standardization for diagnostic radiology, and requirements proposal for calibration laboratories; Padronizacao da grandeza Kerma no ar para radiodiagnostico e proposta de requisitos para laboratorios de calibracao

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Manoel Mattos Oliveira

    2009-07-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. A metrology network was created, but it is not yet accredited by the accreditation organism of the country, INMETRO. The objective of this work was to implement the standardization of the air kerma for the un attenuated qualities (RQR) of IEC 61267, and to develop a requirement proposal for instruments calibration laboratories. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. A laboratory requirement proposal was finalized and it shall be submitted to INMETRO to be used as auxiliary normative document in laboratory accreditation. (author)

  17. 75 FR 51020 - Third Party Testing for Certain Children's Products; Mattresses, Mattress Pads, and/or Mattress...

    Science.gov (United States)

    2010-08-18

    ... Standardization (ISO)/International Electrotechnical Commission (IEC) Standard 17025:2005, ``General Requirements... and of the requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the... body that was ISO/IEC 17025 accredited by an ILAC-MRA member at the time of the test. For firewalled...

  18. Expression of the Wilms' tumor gene WT1 in the murine urogenital system.

    Science.gov (United States)

    Pelletier, J; Schalling, M; Buckler, A J; Rogers, A; Haber, D A; Housman, D

    1991-08-01

    The Wilms' tumor gene WT1 is a recessive oncogene that encodes a putative transcription factor implicated in nephrogenesis during kidney development. In this report we analyze expression of WT1 in the murine urogenital system. WT1 is expressed in non-germ-cell components of the testis and ovaries in both young and adult mice. In situ mRNA hybridization studies demonstrate that WT1 is expressed in the granulosa and epithelial cells of ovaries, the Sertoli cells of the testis, and in the uterine wall. In addition to the 3.1-kb WT1 transcript detected by Northern blotting of RNA from kidney, uterus, and gonads, there is an approximately 2.5-kb WT1-related mRNA species in testis. The levels of WT1 mRNA in the gonads are among the highest observed, surpassing amounts detected in the embryonic kidney. During development, these levels are differentially regulated, depending on the sexual differentiation of the gonad. Expression of WT1 mRNA in the female reproductive system does not fluctuate significantly from days 4 to 40 postpartum. In contrast, WT1 mRNA levels in the tesis increase steadily after birth, reaching their highest expression levels at day 8 postpartum and decreasing slightly as the animal matures. Expression of WT1 in the gonads is detectable as early as 12.5 days postcoitum (p.c.). As an initial step toward exploring the tissue-specific expression of WT1, DNA elements upstream of WT1 were cloned and sequenced. Three putative transcription initiation sites, utilized in testis, ovaries, and uterus, were mapped by S1 nuclease protection assays. The sequences surrounding these sites have a high G + C content, and typical upstream CCAAT and TATAA boxes are not present. These studies allowed us to identify the translation initiation site for WT1 protein synthesis. We have also used an epitope-tagging protocol to demonstrate that WT1 is a nuclear protein, consistent with its role as a transcription factor. Our results demonstrate regulation of WT1 expression

  19. Comparison of electrochemical performance of as-cast Pb-1 wt.% Sn and Pb-1 wt.% Sb alloys for lead-acid battery components

    Energy Technology Data Exchange (ETDEWEB)

    Osorio, Wislei R.; Peixoto, Leandro C.; Garcia, Amauri [Department of Materials Engineering, University of Campinas - UNICAMP, PO Box 612, 13083-970 Campinas, SP (Brazil)

    2010-03-15

    A comparative experimental study of the electrochemical features of as-cast Pb-1 wt.% Sn and Pb-1 wt.% Sb alloys is carried out with a view to applications in the manufacture of lead-acid battery components. The as-cast samples are obtained using a water-cooled unidirectional solidification system. Pb-Sn and Pb-Sb alloy samples having similar coarse cell arrays are subjected to corrosion tests in order to assess the effect of Sn or Sb segregation in the cell boundary on the electrochemical performance. Electrochemical impedance spectroscopy (EIS) diagrams, potentiodynamic polarization curves and an equivalent circuit analysis are used to evaluate the electrochemical parameters in a 0.5 M H{sub 2}SO{sub 4} solution at 25 C. Both the experimental and simulated EIS parameters evidence different kinetics of corrosion. The Pb-1 wt.% Sn alloy is found to have a current density which is of about three times lower than that of the Pb-1 wt.% Sb alloy which indicates that dilute Pb-Sn alloys have higher potential for application as positive grid material in maintenance-free Pb-acid batteries. (author)

  20. The design of management system guidelines and technical standards for the production of x-ray aircraft

    International Nuclear Information System (INIS)

    Dyah Palupi; Made Pramayuni

    2013-01-01

    Concept of management systems guidelines and technical standards X-ray Equipment Production arranged in order to prepare for the effective and efficient regulatory to ensure the safety of X-ray equipment production in Indonesia. The regulatory tools may the government policy or regulations. Authors proposed that BAPETEN develop guidelines for management system of x-ray equipment production by combining ISO 13485 with BAPETEN Chairman Regulation no.4 /2010. Author also suggested that BAPETEN make technical standards IEC 60601 as a mandatory standard in producing x-ray equipment. (author)

  1. Fiscal 2000 project for development of international standards for supporting novel industries. Standardization for enhanced interoperability between optical disk systems; 2000 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Hikari disk system no sogo un'yosei kakuho no tame no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Research and development was carried out for the enhancement of logical format-based interoperability between optical disk systems for the purpose of presenting propositions for international standards. That is, UDF (universal disk format) defined by OSTA (Optical Storage Technology Association) was taken up against the volume/file structure defined by ISO/IEC13346, and efforts were exerted to substantiate environments for its compatibility test and to develop specifications to achieve such enhanced interoperability. In this fiscal year, specifications were drafted for application program interfaces for the UDF-based file system and UDF security augmentation. These would be presented to IEC (International Electrotechnical Commission) and OSTA, respectively. Their Japanese versions were submitted to the Ministry of Economy, Trade and Industry of Japan, for publication as standard-related information. Maintenance of UAF (universal accessible file) system-compliance test tools were accomplished in response to user requirements and to the updating of UDF-compliance test disk specification. (NEDO)

  2. Study on Public Flood Risk Cognition and Behavioral Response Based on IEC Strategy

    Science.gov (United States)

    Shen, Xin; Xu, Xiaofeng; Zhou, Guilin; Pan, Shaolin; Mi, Tengfei

    2017-11-01

    In order to disseminate knowledge and information on flood risks in flood-prone areas, raise public awareness of flood risks and reduce possible damage to the public, a questionnaire survey was coducted among 260 residents of nine selected communities in Jiaozhou City to learn the public awareness and behavioral response to flood risks at different early warning levels. IEC key information of flood risk awareness was modified and formulated through group discussions, in-depth individual interviews and on-site observation. The awareness of residents in the project area was enhanced through the public participation, environmental management and flood management training, which plays a very important role in reducing flood losses.

  3. Infiltration Behavior Of Mechanical Alloyed 75 wt% Cu-25 wt% WC Powders Into Porous WC Compacts

    Directory of Open Access Journals (Sweden)

    Şelte A.

    2015-06-01

    Full Text Available In this work infiltration behavior of mechanical alloyed 75 wt% Cu – 25 wt% WC powders into porous WC compacts were studied. Owing to their ductile nature, initial Cu powders were directly added to mechanical alloying batch. On the other hand initial WC powders were high energy milled prior to mechanical alloying. Contact infiltration method was selected for densification and compacts prepared from processed powders were infiltrated into porous WC bodies. After infiltration, samples were characterized via X-Ray diffraction studies and microstructural evaluation of the samples was carried out via scanning electron microscopy observations. Based on the lack of solubility between WC and Cu it was possible to keep fine WC particles in Cu melt since solution reprecipitation controlled densification is hindered. Also microstructural characterizations via scanning electron microscopy confirmed that the transport of fine WC fraction from infiltrant to porous WC skeleton can be carried out via Cu melt flow during infiltration.

  4. Ontology based integration of heterogeneous structures in the energy industry; Ontologiebasierte Integration heterogener Standards in der Energiewirtschaft

    Energy Technology Data Exchange (ETDEWEB)

    Uslar, Mathias

    2010-07-01

    Today, utilities face a constant change to their business which is mainly driven by two factors. On the one hand, resources like oil and charcoal which deliver most of the energy for producing electricity become more and more scarce and, therefore, more expensive. This forces utilities to look for alternatives to those resources in order to avoid the price pressure. New renewable energy resources like wind turbines, photovoltaic, bio mass or geothermals become more and more popular. On the other hand, the regulation done by the European Commission has a strong impact on the utilities because of the liberalization of the energy markets. The market was opened by the so called unbundling which is, in fact, the separation of the distribution grid from the capability of producing energy which was common before leading to the fact, that the producers of energy also were the only ones which could sell and distribute the energy which lead to monopolistic structures on the market. Nowadays, we have a market where the customers can choose between the offers from different utilities. Those changes to the utility domain have a direct impact on the IT-landscape of the utility who has to deal with new processes which have to be supported by changes like new systems or services and new interfaces between the existing systems in order to support the new requirements. In general, the utility has to deal with standards and norms for the domain in this described setting in order to exchange data with other market participants or in order to integrate their own systems in an appropriate manner. In the electric utility domain, the Common Information Model CIM has spread for the scope of SCADA (supervisory Control and Data Acquisition) and market communications. It is standardized by the IEC (International Electrotechnical Commission) as the IEC 61970 family of standards. The second important family is the IEC 61850 family which deals with communication networks and systems in

  5. 2005 5th Annual CMMI Technology Conference and User Group. Volume 2: Tuesday

    Science.gov (United States)

    2005-11-17

    Happening in ISO ? Work wrapping up on process assessment model for 12207 – Software Life Cycle Processes (15504-5) – to be published Q106, Work...Applicable ISO /IEC documents, including ISO /IEC 12207 and ISO /IEC 15504”; contains two “line item” requirements citing 15504, • ARC draws heavily on 15504...International Standards -2 Key standards identified to date are • ISO 900x:2000 family of standards (as well as selected domain derivatives) • ISO /IEC 12207

  6. Security Process Capability Model Based on ISO/IEC 15504 Conformant Enterprise SPICE

    Directory of Open Access Journals (Sweden)

    Mitasiunas Antanas

    2014-07-01

    Full Text Available In the context of modern information systems, security has become one of the most critical quality attributes. The purpose of this paper is to address the problem of quality of information security. An approach to solve this problem is based on the main assumption that security is a process oriented activity. According to this approach, product quality can be achieved by means of process quality - process capability. Introduced in the paper, SPICE conformant information security process capability model is based on process capability modeling elaborated by world-wide software engineering community during the last 25 years, namely ISO/IEC 15504 that defines the capability dimension and the requirements for process definition and domain independent integrated model for enterprise-wide assessment and Enterprise SPICE improvement

  7. CrossTalk: The Journal of Defense Software Engineering. Volume 19, Number 9

    Science.gov (United States)

    2006-09-01

    activities to ISO /IEC 15288 system life cycle and ISO /IEC 12207 software life cycle processes. • Microsoft Security Development Lifecycle (SDL) [18, 19...Standardization/International Electrotechnical Commission ( ISO / IEC) Standard 15026 System and Software Assurance, which adds securi- ty assurance...Software ProcessSM (TSPSM Secure) [21]. The CMM and ISO /IEC process models are defined at a higher level of abstraction than SDL and CLASP, which

  8. Survey of standards for electronic image displays

    Science.gov (United States)

    Rowe, William A.

    1996-02-01

    Electronic visual displays have been evolving from the 1960's basis of cathode ray tube (CRT) technology. Now, many other technologies are also available, including both flat panels and projection displays. Standards for these displays are being developed at both the national level and the international levels. Standards activity within the United States is in its infancy and is fragmented according to the inclination of each of the standards developing organizations. The latest round of flat panel display technology was primarily developed in Japan. Initially standards arose from component vendor-to-OEM customer relationships. As a result, Japanese standards for components are the best developed. The Electronics Industries Association of Japan (EIAJ) is providing their standards to the International Electrotechnical Commission (IEC) for adoption. On the international level, professional societies such as the human factors society (hfs) and the International Organization for Standardization (ISO) have completed major standards, hfs developed the first ergonomic standard hfs-100 and the ISO has developed some sections of a broader ergonomic standard ISO 9241. This paper addresses the organization of standards activity. Active organizations and their areas of focus are identified. The major standards that have been completed or are in development are described. Finally, suggestions for improving the this standards activity are proposed.

  9. Aggregated wind power plant models consisting of IEC wind turbine models

    DEFF Research Database (Denmark)

    Altin, Müfit; Göksu, Ömer; Hansen, Anca Daniela

    2015-01-01

    The common practice regarding the modelling of large generation components has been to make use of models representing the performance of the individual components with a required level of accuracy and details. Owing to the rapid increase of wind power plants comprising large number of wind...... turbines, parameters and models to represent each individual wind turbine in detail makes it necessary to develop aggregated wind power plant models considering the simulation time for power system stability studies. In this paper, aggregated wind power plant models consisting of the IEC 61400-27 variable...... speed wind turbine models (type 3 and type 4) with a power plant controller is presented. The performance of the detailed benchmark wind power plant model and the aggregated model are compared by means of simulations for the specified test cases. Consequently, the results are summarized and discussed...

  10. Influence of the UV Radiation on Rhodamine WT Fluorescence in Water Samples

    OpenAIRE

    , L. Kola; , P. Lazo

    2016-01-01

    The şuorescence ability of Rhodamine WT enables its using as artiŞcial tracer in the water system studies. The problem is dealt with in relation to applying Rhodamine WT (RhWT) to trace and determine water movements within the karstic system and underground waters. Rhodamine WT has been used as an artiŞcial tracer for the Şrst times in our country on Mali me Gropa system study (2002). UV radiation may induce photochemical decomposition of the dye which can cause large measurement errors on me...

  11. Photolysis of rhodamine-WT dye

    Science.gov (United States)

    Tai, D.Y.; Rathbun, R.E.

    1988-01-01

    Photolysis of rhodamine-WT dye under natural sunlight conditions was determined by measuring the loss of fluorescence as a function of time. Rate coefficients at 30?? north latitude ranged from 4.77 x 10-2 day-1 for summer to 3.16 x 10-2 day-1 for winter. Experimental coefficients were in good agreement with values calculated using a laboratory-determined value of the quantum yield.

  12. 76 FR 18645 - Third Party Testing for Certain Children's Products; Notice of Requirements for Accreditation of...

    Science.gov (United States)

    2011-04-05

    ... to the International Standards Organization (ISO)/International Electrotechnical Commission (IEC) Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and Calibration... paint ban and 16 CFR part 1303, it must be accredited to ISO/IEC 17025- 2005 by an accreditation body...

  13. A hierarchy of SPI activities for software SMEs: results from ISO/IEC 12207-based SPI assessments

    OpenAIRE

    Clarke, Paul; O'Connor, Rory; Yilmaz, Murat

    2012-01-01

    peer-reviewed In an assessment of software process improvement (SPI) in 15 software small- and ???medium-sized enterprises (software SMEs), we applied the broad spectrum of software specific and system context processes in ISO/IEC 12207 to the task of examining SPI in practice. Using the data collected in the study, we developed a four-tiered pyramidal hierarchy of SPI for software SMEs, with processes in the higher tiers undergoing SPI in more companies than processes on lower level tiers...

  14. Arquitectura flexible basada en ISA 88 para el diseño del diagrama de control de ejecución en aplicaciones distribuidas usando IEC 61499

    Directory of Open Access Journals (Sweden)

    Fabricio Chicaiza

    2018-03-01

    Full Text Available En la actualidad los sistemas de automatización industrial deben optimizar las técnicas de control y comunicación de sus procesos, para introducir conceptos dados por la Industria 4.0. Para lograr esto se necesita de la introducción de nuevas normas de automatización para obtener sistemas de fabricación ágiles e inteligentes, es por esto que la norma IEC 61499 es considerada como la opción principal. Industria 4.0 en unión con IEC 61499 permitirá la integración de sistemas de adquisición de datos tradicionales y novedosos sistemas de procesamiento inteligente de datos, con el objetivo de extraer información y mejorar el rendimiento general del sistema productivo. El presente trabajo establece un enfoque de arquitectura flexible para el diseño de los Diagramas de Control de Ejecución de los Bloques de Función basado en la norma ISA 88 aplicado a un proceso industrial, lo que permitirá implementar el control industrial bajo IEC 61499 de manera eficiente y rápida permitiendo un diseño se software basado en componentes con independencia de la plataforma hardware usada.

  15. Technicolor dynamics corrections to Wt-barb coupling

    International Nuclear Information System (INIS)

    Yue Chongxing; Huang Jinshu; Lu Gongru; Yang Zhengtao

    1998-01-01

    The authors consider the contributions of new gauge bosons to Wt-barb coupling in one generation technicolor (OGTC) model and topcolor assisted multiscale technicolor (TOPCMTC) model. The authors find that the exchange of diagonal extended technicolor (ETC) gauge boson has no contribution to Wt-barb coupling. Using the LEP value of R b , the authors calculate the corrections to the CKM matrix element V tb which arise from the sideways ETC gauge boson in OGTC model and the sideways ETC gauge bosons and color exchange in TOPCMTC model. The authors find that the δV tb is significantly large for a certain set of the parameters of either OGTC model or TOPCMTC model which might be detected in the Fermilab Tevatron Run 3 experiments

  16. A survey of the mechanical properties of uranium alloys U-5Mo-3Nb wt.% and U-3Mo-3Nb wt.%

    Energy Technology Data Exchange (ETDEWEB)

    Dupont, G.

    1969-04-15

    In a continuing program on the development of soft and ductile uranium alloys for armament applications, two compositions were studied. These gamma extruded uranium alloys were U-5Mo-3Nb wt.% and U-3Mo-3Nb wt.%. This study was carried out to determine the influence of tempering heat treatments associated with extrusion on the ductility of these uranium alloys. The mechanical properties of both alloys were measured in the extruded condition, in the extruded and annealed condition and in the quenched and tempered condition. A maximum elongation of 13.7% in tension with a low amount of work hardening was obtained for the U-3Mo-3Nb wt.% alloy after 1 1/2 hours anneal at 1200 deg F (650 deg C) followed by a rapid cooling in water at 70 deg F (21 deg C). A maximum elongation of 17.3% with a large amount of work hardening was obtained for alloy U-5Mo-3Nb wt.% after vacuum annealing, normalizing, gamma phase solubilizing at 1500 deg F (815 deg C) and quenching in water at 700 deg F (210 deg C). The maximum ductility achieved in these two alloys by our approaches is low compared with the ductility of Armco Iron employed for the same applications in the field of ballistics.

  17. Nanostructured Titanium-10 wt% 45S5 Bioglass-Ag Composite Foams for Medical Applications

    Directory of Open Access Journals (Sweden)

    Karolina Jurczyk

    2015-03-01

    Full Text Available The article presents an investigation on the effectiveness of nanostructured titanium-10 wt% 45S5 Bioglass-1 wt% Ag composite foams as a novel class of antibacterial materials for medical applications. The Ti-based composite foams were prepared by the combination of mechanical alloying and a “space-holder” sintering process. In the first step, the Ti-10 wt% 45S5 Bioglass-1 wt% Ag powder synthesized by mechanical alloying and annealing mixed with 1.0 mm diameter of saccharose crystals was finally compacted in the form of pellets. In the next step, the saccharose crystals were dissolved in water, leaving open spaces surrounded by metallic-bioceramic scaffold. The sintering of the scaffold leads to foam formation. It was found that 1:1 Ti-10 wt% 45S5 Bioglass-1 wt% Ag/sugar ratio leads to porosities of about 70% with pore diameter of about 0.3–1.1 mm. The microstructure, corrosion resistance in Ringer’s solution of the produced foams were investigated. The value of the compression strength for the Ti-10 wt% 45S5 Bioglass-1 wt% Ag foam with 70% porosity was 1.5 MPa and the Young’s modulus was 34 MPa. Silver modified Ti-10 wt% 45S5 Bioglass composites possess excellent antibacterial activities against Staphylococcus aureus. Porous Ti-10 wt% 45S5 Bioglass-1 wt% foam could be a possible candidate for medical implants applications.

  18. Effect of {gamma}` and {gamma} (Ag{sub 2}Al) precipitates on the steady state creep of Al-16wt%Ag alloys with and without Zr addition

    Energy Technology Data Exchange (ETDEWEB)

    Deaf, G.H. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics; Youssef, S.B. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics; Mahmoud, M.A. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics

    1996-11-16

    The steady state creep behaviour of Al-16 wt% Ag and Al-16 wt% Ag-0.1 wt% Zr alloys has been studied at constant load (= 137.2 MPa) and tested at different working temperatures for samples aged at temperatures favouring the formation of {gamma}` and {gamma} precipitates. It was found that addition of Zr to Al-16 wt% Ag alloy accelerates the precipitations {gamma}` and {gamma} due to the formation of the metastable phase Al{sub 3}Zr. For both alloys, two values of activation energy have been obtained as (34 {+-} 0.3) kJ/mol for viscous glide of dislocations due to the existence of {gamma}` precipitates and (68 {+-} 0.3) kJ/mol for grain boundary diffusion due to the existence of {gamma} precipitates. TEM investigations of {gamma}` and {gamma} precipitates confirmed the above-mentioned effect of Zr addition. (orig.)

  19. Methodology to establish the profile that defines a meta-specification that applies to distribution substations - Mexico case based on norm IEC-61850; Metodologia para establecer el perfil que define una meta-especificacion que aplica a subestaciones de distribucion -caso Mexico- basada en la norma IEC-61850

    Energy Technology Data Exchange (ETDEWEB)

    Picazo Blanquel, Cuitlahuac; Chairez Campos Carlos; Garcia Hernandez, Joaquin; Godinez Enriquez, Hebert; Poujol Galvan, Francisco C.; Suarez Cerda, Dionisio A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Villalobos Ramos, Andres; LLamas Gonzalez, Rosa E. [Comision Federal de Electricidad (Mexico); Samitier Otero, Carlos [Global Networking Engineering (Spain)

    2010-07-01

    In this article is presented a case of study of automation of electrical substations of Comision Federal de Electricidad (CFE) of Mexico, in which the Norm IEC-61850 has been taken as reference. The case of study consists of defining a metaspecification for the protection, control, measurement and communication systems required by the substations of electrical distribution. For the development the obtained previous experience in the development of a bequeathed system SA, norm IEC61850 has been taken as reference, as well as the experiences documented in the Instituto de Investigaciones Electricas (IIE), the Comision Federal de Electricidad (CFE) and Global Networking Engineering (GNE), Spain. This way, the obtained result is the metaspecification, which establishes the application of the control, protective equipment and measurement under the interoperability concepts, as well as the automation functions of substations applied in the intelligent networks (REI's). The methodology put into practice includes the design of the system architecture (SAS), the operation philosophy, the topology of the communications network, the data modeling one with logical nodes that include data types and classes of common data (CDC), transference of information, and administration of the archives ICD, SSD, SCD, and CID. [Spanish] En este articulo se presenta un caso de estudio de automatizacion de subestaciones electricas de la Comision Federal de Electricidad (CFE) de Mexico, en el cual se ha tomado como referencia la norma IEC-61850. El caso de estudio consiste en definir una metaespecificacion para los sistemas proteccion, control, medicion y comunicaciones requeridos por las subestaciones de distribucion electrica. Para el desarrollo se ha tomado como referencia la experiencia previa obtenida en el desarrollo de un sistema SA legado, la norma IEC61850, asi como las experiencias documentadas en el Instituto de Investigaciones Electricas (IIE), la Comision Federal de

  20. Implementation of IEC Generic Model Type 1 Wind Turbine Generators using RTDS

    DEFF Research Database (Denmark)

    Cha, Seung-Tae; Wu, Qiuwei; Zhao, Haoran

    With the ever increasing penetration of the wind power generation, transmission system operators (TSOs) and distribution system operators (DSOs) are demanding an accurate dynamic wind turbine generator (WTG) models for power system stability studies. However, the confidential requirements from wind...... are useful tools to evaluate the impact of the wind power on the power system stability. Thus, a strong stimulus exists for the development of a generic dynamic model in order to further investigate the dynamic response of WTG under grid disturbances. This paper presents the implementation of the IEC generic...... turbine manufacturers prevent the academia and researchers from working on a real or/and manufacturer specific models. A generic WTG model is of great interest that does not contain the confidential information meanwhile represents the manufacturer specific models. These generic dynamic simulation models...

  1. Fiscal 1999 technical achievement report. Research and development project on the quickly effective international standards creation (Standardization of information security system evaluating methods); 1999 nendo sokkogata kokusai hyojun sosei kenkyu kaihatsu jigyo seika hokokusho. Joho security system no hyoka hoho no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For standardization under information security evaluation criteria, an evaluating technique CEM (Common Methodology for Information Technology Security Evaluation) was constructed as ISI/IEC15408. The method, however, is abstract in content and the evaluation work thereunder requires much time and accompanies economic difficulties. In dealing with the situation, investigations were conducted into security evaluation related techniques and manufacturing/quality control techniques in use at information processing product developing sites, and a CEM technique is materialized. Using the proposed technique, developers themselves can evaluate security in the development process and workloads imposed on evaluating organizations may be reduced because evidential items necessary for 3rd party evaluation may be gathered. Since the developed technique is verified by an official evaluating organization, it is expected to be an effective techniques not contradicting existing operating techniques. It may be also said that this technique is a method whereby developers will collect evidential items necessary for their development efforts. The result will be presented in the form of a proposal for an evaluating techniques standard for ISO/IEC JTC1 SC27. (NEDO)

  2. CMMI (Trademark) for Development, Version 1.2

    Science.gov (United States)

    2006-08-01

    IEC TR 12207 Information Technology—Software Life Cycle Processes, 1995. http://www.jtc1-sc7.org. ISO 1998 International Organization for...We also consult other standards as needed, including the following: • ISO 9000 [ ISO 1987] • ISO /IEC 12207 [ ISO 1995] • ISO /IEC 15504 [ ISO 2006... ISO /IEC) body of standards. CMMs focus on improving processes in an organization. They contain the essential elements of effective processes for one

  3. 75 FR 31688 - Third Party Testing for Certain Children's Products; Infant Bath Seats: Requirements for...

    Science.gov (United States)

    2010-06-04

    ... requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the CPSC staff briefing....html . The accreditation must be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the... tested by a third party conformity assessment body that was ISO/IEC 17025 accredited by an ILAC-MRA...

  4. 75 FR 35282 - Third Party Testing for Certain Children's Products; Infant Walkers: Requirements for...

    Science.gov (United States)

    2010-06-21

    ... requirements of the ISO/IEC 17025:2005 laboratory accreditation standard is provided in the CPSC staff briefing... to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and... tested by a third party conformity assessment body that was ISO/IEC 17025 accredited by an ILAC-MRA...

  5. 75 FR 42311 - Third Party Testing for Certain Children's Products; Vinyl Plastic Film: Requirements for...

    Science.gov (United States)

    2010-07-21

    ... ISO/IEC 17025:2005 laboratory accreditation standard is provided in the CPSC staff briefing memorandum....org/membersbycategory.html . The accreditation must be to ISO Standard ISO/IEC 17025:2005, ``General... conformity assessment body that was ISO/IEC 17025 accredited by an ILAC-MRA member at the time of the test...

  6. EVALUASI KEAMANAN INFORMASI PADA PTI PDAM TIRTA MOEDAL KOTA SEMARANG BERDASARKAN INDEKS KEAMANAN INFORMASI SNI ISO/IEC 27001:2009

    Directory of Open Access Journals (Sweden)

    Diah Restu Wardani

    2015-10-01

    Full Text Available Adanya rencana untuk meningkatkan keamanan informasi sesuai dengan Standar Nasional Indonesia (SNI. Selain rencana tersebut, ditemukan kurangnya kesadaran dari masing-masing staff PTI PDAM Tirta Moedal Kota Semarang terkait dengan keamanan informasi menyebabkan terjadinya berbagai masalah salah satunya penyalahgunaan wewenang yang dilakukan oleh staff PTI yaitu dengan mengubah sistem operasi yang telah ditetapkan oleh PTI PDAM dan kejadian tersebut berdampak pada proses bisnis. Ditemukan pula bahwa kurangnya pengamanan pada ruang server yang ada di divisi PTI. Tujuan dari penelitian ini adalah untuk mengevaluasi tingkat kelengkapan dan tingkat kematangan keamanan informasi pada divisi PTI serta memberikan rekomendasi perbaikan untuk meningkatkan tingkat kelengkapan dan tingkat kematangan keamanan informasi. Dari hasil studi dokumen, wawancara, dan kuesioner berdasarkan Indeks Keamanan Informasi SNI ISO/IEC 27001:2009 dihasilkan tingkat kelengkapan keamanan informasi sebesar 325 dan tingkat kematangan berada pada tingkat I+ dimana sudah ada pemahaman mengenai perlunya pengelolaan kemanan informasi akan tetapi penerapan langkah pengamanan masih belum teratur. Untuk mencapai tingkat kematangan V dan sesuai dengan Standar Nasional Indonesia (SNI PTI PDAM Tirta Moedal Kota Semarang dapat melakukan strategi perbaikan secara bertahap. Kata Kunci: Indeks Keamanan Informasi, SNI ISO/IEC 27001:2009, Evaluasi Keamanan Informasi, Tingkat Kelengkapan, Tingkat Kematangan

  7. Electrochemical corrosion of Pb-1 wt% Sn and Pb-2.5 wt% Sn alloys for lead-acid battery applications

    Energy Technology Data Exchange (ETDEWEB)

    Osorio, Wislei R.; Peixoto, Leandro C.; Garcia, Amauri [Department of Materials Engineering, State University of Campinas - UNICAMP, PO Box 612, 13083-970 Campinas, SP (Brazil)

    2009-12-01

    The aim of this study was to compare the electrochemical corrosion behavior of as-cast Pb-1 wt% Sn and Pb-2.5 wt% Sn alloy samples in a 0.5 M H{sub 2}SO{sub 4} solution at 25 C. A water-cooled unidirectional solidification system was used to obtain the as-cast samples. Electrochemical impedance spectroscopy (EIS) diagrams, potentiodynamic polarization curves and an equivalent circuit analysis were used to evaluate the electrochemical corrosion response. It was found that a coarse cellular array has a better electrochemical corrosion resistance than fine cells. The pre-programming of microstructure cell size of Pb-Sn alloys can be used as an alternative way to produce as-cast components of lead-acid batteries with higher corrosion resistance associated with environmental and economical aspects. (author)

  8. Combining ISO/IEC 17025:2005 and European Commission Decision 2002/657 audit requirements: a practical way forward.

    Science.gov (United States)

    Kay, Jack F

    2012-08-01

    Laboratories involved in the analyses of veterinary drug residues are under increasing pressure to demonstrate that they produce meaningful and reliable data. Quality assurance and quality control systems are implemented in laboratories to provide evidence of this and these are subject to external assessment to ensure that they are effective. Audits to ISO/IEC 17025:2005, an internationally accepted standard, and subsequent accreditation provide laboratories and their customers with a degree of assurance that the laboratories are operating in control and the data they report can be relied on. However, national or regional authorities may place additional requirements on laboratories to ensure quality data are reported. For example, in the European Union, all official control laboratories involved in veterinary drug residue analyses must also meet the requirements of European Commission Decision 2002/657/EC which sets performance criteria for analytical methods used in this area and these are subject to additional audits by national or regional authorities. All audits place considerable time and resource demands on laboratories and this paper discusses the burden audits place on laboratories and describes a UK initiative to combine these audits to the benefit of both the regulatory authority and the laboratory. © 2012 John Wiley & Sons, Ltd.

  9. On the synthesis and characterization of some new AB{sub 5} type MmNi{sub 4.3}Al{sub 0.3},Mn{sub 0.4}, LaNi{sub 5-{chi}}Si{sub {chi}} ({chi} = 0.1, 0.3, 0.5) and Mg-{chi} wt% CFMmNi{sub 5}-y wt% Si hydrogen storage materials

    Energy Technology Data Exchange (ETDEWEB)

    Srivistava, S.; Sai Raman, S.S.; Singh, B.K.; Srivistava, O.N. [Banaras Hindu Univ., Varanasi (India). Dept. of Physics

    2000-05-01

    The viability and feasibility of Hydrogen Energy becoming the clean alternative to Fossil Fuel Energy through replacement of 'Fossil Fuel' with 'Hydrogen' (the Green Fuel) is inextricably interlinked with development of 'Hydrogen Storage Systems'. Out of the high pressure gaseous hydrogen, liquid hydrogen, storage in glass microspheres, activated carbon, zeolites, hydrogen rich liquids and solid state hydrides, the last option is of implicit importance. Out of the AB (e.g., FeTi, storage capacity -- 1.75 wt%), AB{sub 2} or A{sub 2}B (Mg{sub 2}Ni -- 3.8 wt%), AB{sub 5} (LaNi{sub 5}, MmN{sub 5} -- 1.5 wt%) and K{sub 2} PtCl{sub 6} type (Mg{sub 2}FeH{sub 6} -- 5.2 wt%); the AB{sub 5} type holds potential promise due to easy activation, tolerance to impurities of charging H{sub 2} gas and avid amenability towards material tailoring for improved and better hydrogenation characteristics. We have carried out synthesis, characterization of several of the AB{sub 5} type storage materials. The present paper is aimed at describing and discussing some of our more recent efforts in regard to this. In the present study the hydrogen storage material (MH) has been synthesized through normal casting (Radio Frequency (RF) induction melting) and melt-spinning techniques. The improvements in basic alloys LaNi{sub 5}/MmNi{sub 5} have been studied through structural, microstructural and hydrogenation characteristics. The main features revealed by XRD characterizations are the existence of the free Ni and Si together with AB{sub 5} material in melt-spun alloy of LaNi{sub 5-{chi}}Si{sub {chi}}. These free Ni and Si were found to disappear, giving rise to a singular material after hydrogenation. Also in melt-spun alloy growth has taken place in a direction perpendicular to the c-axis. Melt-spun version was found to be superior over bulk version in regard to kinetics and activation process. For MmNi{sub 4.3}AlO{sub 3}Mn{sub 0.4} alloy, melt-spun version has

  10. Isolating $Wt$ production at the LHC

    CERN Document Server

    White, Chris D; Laenen, Eric; Maltoni, Fabio

    2009-01-01

    We address the issue of single top production in association with a W boson at the Large Hadron Collider, in particular how to obtain an accurate description in the face of the top pair production background given that the two processes interfere with each other. We stress the advantages of an MC@NLO description, and find that for cuts used to isolate the signal, it makes sense to consider Wt as a well-defined production process in that the interference with top pair production is small, and the cross-section of the former is above the scale variation uncertainty associated with the latter. We also consider the case where both Wt and top pair production are backgrounds to a third process (Higgs boson production followed by decay to a W boson pair), and find in this context that interference issues can also be neglected. We discuss the generalization of our results to other situations, aided by a comparison between the MC@NLO approach and a calculation of the WWbb final state matched to a parton shower.

  11. VICbus: A standard inter-crate bus

    International Nuclear Information System (INIS)

    Parkman, C.F.

    1990-01-01

    VICbus is a standard inter-crate cable bus being developed by a working group of the ISO/IEC. Derived from an initiative of the VMEbus Working Group of ESONE, VICbus aims to provide users of multi-crate VMEbus and other backplane bus systems with a standard inter-crate connection. Multi-drop operation is provided for up to 31 devices on a cable of maximum 100 metres in length. Two data transfer protocols are specified, compelled (asynchronous) transfers for transparent interconnection of backplane bus systems (VMEbus in the first instance), and high-speed, non-compelled (synchronous) transfers between VICbus interfaces. A limited interrupt mechanism is specified, as well as simple, but efficient arbitration technique. Conventional technology is employed: copper cables, existing transcievers, and differential signal transmission, together with proven low-level protocols. Data transfer rates in excess of 30 Mbyte/s will be possible on a cable length of 30 metres

  12. Special Testing for Modules Deployed in Hot Use Environments - Are We Doing This in a Low-Cost Way?

    Energy Technology Data Exchange (ETDEWEB)

    Repins, Ingrid; Jordan, Dirk; Bosco, Nick; Flueckiger, Chris

    2016-09-12

    The proposed new IEC standard will address the test temperature requirements in IEC 61215 (module design), IEC 61730 (module safety), IEC 62790 (junction box safety) and IEC 62852 (connectors), and will provide guidelines to modify temperature limits in four existing standards to better describe module performance in hotter climates. This workshop includes four presentations: Special Testing for Modules Deployed in Hot Use Environments - Are We Doing This in a Low-Cost Way?, Experimental Evidence, Why the highest temperatures are the most stressful to PV modules during thermal cycling, and Safety Aspects for Modules Deployed in Hot Use Environments.

  13. The organization of the International Electrotechnical Commission and present condition

    International Nuclear Information System (INIS)

    1999-07-01

    This book contains seven character with the introduction of the IEC, organization of the IEC and functions, proposal of the international standard of IEC, the procedures for the program of work and target dates, certification system of IECEE, IECQ and IECEX scheme, the recent trends of IEC and how to use of publication of the IEC.

  14. Can T1 w/T2 w ratio be used as a myelin-specific measure in subcortical structures? Comparisons between FSE-based T1 w/T2 w ratios, GRASE-based T1 w/T2 w ratios and multi-echo GRASE-based myelin water fractions.

    Science.gov (United States)

    Uddin, Md Nasir; Figley, Teresa D; Marrie, Ruth Ann; Figley, Chase R

    2018-03-01

    Given the growing popularity of T 1 -weighted/T 2 -weighted (T 1 w/T 2 w) ratio measurements, the objective of the current study was to evaluate the concordance between T 1 w/T 2 w ratios obtained using conventional fast spin echo (FSE) versus combined gradient and spin echo (GRASE) sequences for T 2 w image acquisition, and to compare the resulting T 1 w/T 2 w ratios with histologically validated myelin water fraction (MWF) measurements in several subcortical brain structures. In order to compare these measurements across a relatively wide range of myelin concentrations, whole-brain T 1 w magnetization prepared rapid acquisition gradient echo (MPRAGE), T 2 w FSE and three-dimensional multi-echo GRASE data were acquired from 10 participants with multiple sclerosis at 3 T. Then, after high-dimensional, non-linear warping, region of interest (ROI) analyses were performed to compare T 1 w/T 2 w ratios and MWF estimates (across participants and brain regions) in 11 bilateral white matter (WM) and four bilateral subcortical grey matter (SGM) structures extracted from the JHU_MNI_SS 'Eve' atlas. Although the GRASE sequence systematically underestimated T 1 w/T 2 w values compared to the FSE sequence (revealed by Bland-Altman and mountain plots), linear regressions across participants and ROIs revealed consistently high correlations between the two methods (r 2 = 0.62 for all ROIs, r 2 = 0.62 for WM structures and r 2 = 0.73 for SGM structures). However, correlations between either FSE-based or GRASE-based T 1 w/T 2 w ratios and MWFs were extremely low in WM structures (FSE-based, r 2 = 0.000020; GRASE-based, r 2 = 0.0014), low across all ROIs (FSE-based, r 2 = 0.053; GRASE-based, r 2 = 0.029) and moderate in SGM structures (FSE-based, r 2 = 0.20; GRASE-based, r 2 = 0.17). Overall, our findings indicated a high degree of correlation (but not equivalence) between FSE-based and GRASE-based T 1 w/T 2 w ratios, and low correlations between T 1 w/T 2 w ratios and MWFs. This

  15. IEC Newsletter, No. 47, First Quarter 2014

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-05-15

    The ConvEx-3 (2013) evaluation meeting - the Fifth Meeting of the Inter-Agency Committee on Radiological and Nuclear Emergencies Working Group on Coordinated International Exercises (IACRNE-WG-CIE) - took place at IAEA Headquarters in Vienna from 11-12 February 2014. Representatives from the Moroccan authorities, members of the IACRNE Working Group on Coordinated International Exercises, exercise chief evaluators, and the chairperson of the National Competent Authority Coordination Group (NCACG) were invited and participated in the meeting. The objectives of the meeting were to evaluate the ConvEx-3 (2013) exercise, to review the draft Exercise Report, and to discuss exercise findings and conclusions. On the first day of the meeting (11 February), the exercise was evaluated by the host country Morocco and by chief evaluators of some international organizations and Member States. National objectives, findings, conclusions and recommendations for emergency preparedness and response improvements were presented and discussed. On the second day (12 February), the Lead Exercise Evaluator and chair of the ICARNE WG-CIE, presented the draft Exercise Report, and proposals for common findings, conclusions and recommendations based on the Chief Evaluator's reports were consolidated. It was also agreed that the revised draft Exercise Report will be distributed for comment and feedback to all chief evaluators who have submitted evaluation reports to the IAEA. The ConvEx-3 exercise was conducted by the Incident and Emergency Centre (IEC) on 20-21 November 2013. Fifty-nine Member States (including Morocco) and ten international organizations (including the IAEA) participated in the exercise.

  16. IEC Newsletter, No. 47, First Quarter 2014

    International Nuclear Information System (INIS)

    2014-05-01

    The ConvEx-3 (2013) evaluation meeting - the Fifth Meeting of the Inter-Agency Committee on Radiological and Nuclear Emergencies Working Group on Coordinated International Exercises (IACRNE-WG-CIE) - took place at IAEA Headquarters in Vienna from 11-12 February 2014. Representatives from the Moroccan authorities, members of the IACRNE Working Group on Coordinated International Exercises, exercise chief evaluators, and the chairperson of the National Competent Authority Coordination Group (NCACG) were invited and participated in the meeting. The objectives of the meeting were to evaluate the ConvEx-3 (2013) exercise, to review the draft Exercise Report, and to discuss exercise findings and conclusions. On the first day of the meeting (11 February), the exercise was evaluated by the host country Morocco and by chief evaluators of some international organizations and Member States. National objectives, findings, conclusions and recommendations for emergency preparedness and response improvements were presented and discussed. On the second day (12 February), the Lead Exercise Evaluator and chair of the ICARNE WG-CIE, presented the draft Exercise Report, and proposals for common findings, conclusions and recommendations based on the Chief Evaluator's reports were consolidated. It was also agreed that the revised draft Exercise Report will be distributed for comment and feedback to all chief evaluators who have submitted evaluation reports to the IAEA. The ConvEx-3 exercise was conducted by the Incident and Emergency Centre (IEC) on 20-21 November 2013. Fifty-nine Member States (including Morocco) and ten international organizations (including the IAEA) participated in the exercise

  17. BASP1 is a transcriptional cosuppressor for the Wilms' tumor suppressor protein WT1

    DEFF Research Database (Denmark)

    Carpenter, Brian; Hill, Kathryn J; Charalambous, Marika

    2004-01-01

    The Wilms' tumor suppressor protein WT1 is a transcriptional regulator that plays a key role in the development of the kidneys. The transcriptional activation domain of WT1 is subject to regulation by a suppression region within the N terminus of WT1. Using a functional assay, we provide direct...... evidence that this requires a transcriptional cosuppressor, which we identify as brain acid soluble protein 1 (BASP1). WT1 and BASP1 associate within the nuclei of cells that naturally express both proteins. BASP1 can confer WT1 cosuppressor activity in transfection assays, and elimination of endogenous...

  18. Co-processing of standard gas oil and biocrude oil to hydrocarbon fuels

    International Nuclear Information System (INIS)

    Agblevor, Foster A.; Mante, O.; McClung, R.; Oyama, S.T.

    2012-01-01

    The major obstacle in thermochemical biomass conversion to hydrocarbon fuels using pyrolysis has been the high oxygen content and the poor stability of the product oils, which cause them to solidify during secondary processing. We have developed a fractional catalytic pyrolysis process to convert biomass feedstocks into a product termed “biocrude oils” (stable biomass pyrolysis oils) which are distinct from unstable conventional pyrolysis oils. The biocrude oils are stable, low viscosity liquids that are storable at ambient conditions without any significant increases in viscosity; distillable at both atmospheric pressure and under vacuum without char or solid formation. About 15 wt% biocrude oils containing 20–25% oxygen were blended with 85 wt% standard gas oil and co-cracked in an Advanced Catalyst Evaluation (ACE™) unit using fluid catalytic cracking (FCC) catalysts to produce hydrocarbon fuels that contain negligible amount of oxygen. For the same conversion of 70% for both the standard gas oil and the biocrude oil/gas oil blends, the product gasoline yield was 44 wt%, light cycle oil (LCO) 17 wt%, heavy cycle oil (HCO) 13 wt%, and liquefied petroleum gas (LPG) 16 wt%. However, the coke yield for the standard gas oil was 7.06 wt% compared to 6.64–6.81 wt% for the blends. There appeared to be hydrogen transfer from the cracking of the standard gas oil to the biocrude oil which subsequently eliminated the oxygen in the fuel without external hydrogen addition. We have demonstrated for the first time that biomass pyrolysis oils can be successfully converted into hydrocarbons without hydrogenation pretreatment. -- Highlights: ► The co-processed product had less than 1% oxygen content and contained biocarbons determined by 14 C analysis. ► The co-processing did not affect the yields of gasoline, LCO, and HCO. ► First demonstration of direct conversion of pyrolysis oils into drop-in hydrocarbon fuels.

  19. Physical properties of monolithic U8 wt.%-Mo

    Science.gov (United States)

    Hengstler, R. M.; Beck, L.; Breitkreutz, H.; Jarousse, C.; Jungwirth, R.; Petry, W.; Schmid, W.; Schneider, J.; Wieschalla, N.

    2010-07-01

    As a possible high density fuel for research reactors, monolithic U8 wt.%-Mo ("U8Mo") was examined with regard to its structural, thermal and electric properties. X-ray diffraction by the Bragg-Brentano method was used to reveal the tetragonal lattice structure of rolled U8Mo. The specific heat capacity of cast U8Mo was determined by differential scanning calorimetry, its thermal diffusivity was measured by the laser flash method and its mass density by Archimedes' principle. From these results, the thermal conductivity of U8Mo in the temperature range from 40 °C to 250 °C was calculated; in the measured temperature range, it is in good accordance with literature data for UMo with 8 and 9 wt.% Mo, is higher than for 10 wt.% Mo and lower than for 5 wt.% Mo. The electric conductivity of rolled and cast U8Mo was measured by a four-wire method and the electron based part of the thermal conductivity calculated by the Wiedemann-Frantz law. Rolled and cast U8Mo was irradiated at about 150 °C with 80 MeV 127I ions to receive the same iodine ion density in the damage peak region as the fission product density in the fuel of a typical high flux reactor after the targeted nuclear burn-up. XRD analysis of irradiated U8Mo showed a change of the lattice parameters as well as the creation of UO 2 in the superficial sample regions; however, a phase change by irradiation was not observed. The determination of the electron based part of the thermal conductivity of the irradiated samples failed due to high measurement errors which are caused by the low thickness of the damage region in the ion irradiated samples.

  20. Validation of powder X-ray diffraction following EN ISO/IEC 17025.

    Science.gov (United States)

    Eckardt, Regina; Krupicka, Erik; Hofmeister, Wolfgang

    2012-05-01

    Powder X-ray diffraction (PXRD) is used widely in forensic science laboratories with the main focus of qualitative phase identification. Little is found in literature referring to the topic of validation of PXRD in the field of forensic sciences. According to EN ISO/IEC 17025, the method has to be tested for several parameters. Trueness, specificity, and selectivity of PXRD were tested using certified reference materials or a combination thereof. All three tested parameters showed the secure performance of the method. Sample preparation errors were simulated to evaluate the robustness of the method. These errors were either easily detected by the operator or nonsignificant for phase identification. In case of the detection limit, a statistical evaluation of the signal-to-noise ratio showed that a peak criterion of three sigma is inadequate and recommendations for a more realistic peak criterion are given. Finally, the results of an international proficiency test showed the secure performance of PXRD. © 2012 American Academy of Forensic Sciences.

  1. Understanding the Perception of Very Small Software Companies towards the Adoption of Process Standards

    Science.gov (United States)

    Basri, Shuib; O'Connor, Rory V.

    This paper is concerned with understanding the issues that affect the adoption of software process standards by Very Small Entities (VSEs), their needs from process standards and their willingness to engage with the new ISO/IEC 29110 standard in particular. In order to achieve this goal, a series of industry data collection studies were undertaken with a collection of VSEs. A twin track approach of a qualitative data collection (interviews and focus groups) and quantitative data collection (questionnaire) were undertaken. Data analysis was being completed separately and the final results were merged, using the coding mechanisms of grounded theory. This paper serves as a roadmap for both researchers wishing to understand the issues of process standards adoption by very small companies and also for the software process standards community.

  2. The role of Ag precipitates in Cu-12 wt% Ag

    Energy Technology Data Exchange (ETDEWEB)

    Yao, D.W.; Song, L.N. [Department of Materials Science and Engineering, Zhejiang University, Zheda Road No.38, Hangzhou, Zhejiang 310027 (China); Dong, A.P.; Wang, L.T. [China Railway Construction Electrification Bureau Group Co.,Ltd., Beijing 100036 (China); Zhang, L. [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Meng, L., E-mail: mengliang@zju.edu.cn [Department of Materials Science and Engineering, Zhejiang University, Zheda Road No.38, Hangzhou, Zhejiang 310027 (China)

    2012-12-15

    The Cu-12 wt% Ag was prepared to investigate the role of Ag precipitates on the properties of the alloy. Two kinds of heat treatment procedures were adopted to produce different amount of Ag precipitates in the Cu-12 wt% Ag. The microstructure of Ag precipitates was systematically observed by optical microscopy and electron microscopy. The Cu-12 wt% Ag with more Ag precipitates exhibits higher strength and lower electrical conductivity. More Ag precipitates results in more phase interface and less Ag atoms dissolved in Cu matrix. By comparing the strengthening effect and electron scattering effect of phase interface and dissolved Ag atoms, it is conclude that the interface between Cu matrix and Ag precipitates could significantly block dislocation movement and enhance electron scattering in Cu-Ag alloys.

  3. Standards for Lithotripter Performance

    Science.gov (United States)

    Schultheiss, Reiner; Doerffel, Michael

    2008-09-01

    Standards for lithotripsy have been developed by the International Electrotechnical Commission (IEC) and the FDA. In addition to the existing regulations and norms for the manufacturers, special standards were developed to address a treatment method developed in the early 1980's using extracorporeal shock waves. Initially, the FDA regulated the premarket approval process for lithotripters as a Class III device but reclassified lithotripters in 2000 to a Class II device. The corresponding guidance document for showing the substantial equivalence of new devices with predicate devices will be described in detail. The FDA guidance document is very useful in helping device manufacturers: (i) develop technical performance testing for a shock wave lithotripter within the parameters of an FDA submission, and (ii) conduct clinical performance testing via at least one clinical confirmation study with a small number of subjects. Unfortunately although the submitted data are available at the FDA they are not available in the marketplace and this causes difficulties for physicians in deciding which device to use. The results of the technical performance testing of the LithoGold™ are provided.

  4. Atvērtā pirmkoda programmatūras pielietojuma iespējas ISO/IEC 27000 standartu sērijas prasību apmierināšanai

    OpenAIRE

    Vasiļjevs, Oļegs

    2014-01-01

    Bakalaura darba ietvaros tiek apskatīta un izanalizēta informācijas drošības pārvaldes sistēmas apakškategorija - ISO/IEC 27000 standartu sērijā. Ievērojot sertifikāta iegūšanas projekta apjomu un standartu kopas īpatnējo “zarošanas” struktūru, ir viegli definējams galvenais darba uzdevums – saprast kas tieši ir vajadzīgs no sistēmas administratora, lai īstenotu savu darba daļu pietiekami ātri. Galvenais darba mērķis ir sniegt vienkāršoto ISO/IEC 27000 standartu sērijas prasības izklāstu sis...

  5. TRIGA high wt -% LEU fuel development program. Final report

    International Nuclear Information System (INIS)

    West, G.B.

    1980-07-01

    The principal purpose of this work was to investigate the characteristics of TRIGA fuel where the contained U-235 was in a relatively high weight percent (wt %) of LEU (low enriched uranium - enrichment of less than 20%) rather than a relatively low weight percent of HEU (high enriched uranium). Fuel with up to 45 wt % U was fabricated and found to be acceptable after metallurgical examinations, fission product retention tests and physical property examinations. Design and safety analysis studies also indicated acceptable prompt negative temperature coefficient and core lifetime characteristics for these fuels

  6. Final Report - Certifying the Performance of Small Wind Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Sherwood, Larry [Small Wind Certification Council, Clifton Park, NY (United States)

    2015-08-28

    The Small Wind Certification Council (SWCC) created a successful accredited certification program for small and medium wind turbines using the funding from this grant. SWCC certifies small turbines (200 square meters of swept area or less) to the American Wind Energy Association (AWEA) Small Wind Turbine Performance and Safety Standard (AWEA Standard 9.1 – 2009). SWCC also certifies medium wind turbines to the International Electrical Commission (IEC) Power Performance Standard (IEC 61400-12-1) and Acoustic Performance Standard (IEC 61400-11).

  7. Characterization and expression of the human T cell receptor-T3 complex by monoclonal antibody F101.01

    DEFF Research Database (Denmark)

    Geisler, C; Plesner, T; Pallesen, G

    1988-01-01

    A murine monoclonal antibody (MoAb) F101.01 reacting with the T cell receptor (TCR)-T3 complex is presented. Immunohistological studies showed that F101.01 specifically stains T-zone lymphocytes in lymph nodes, tonsils, and splenic tissue. Two-colour immunofluorescence and flow cytometry...... demonstrated co-expression of the antigen defined by F101.01 and the pan-T cell antigens defined by CD2, CD3, CD5, and CD7 antibodies. Cells stained with CD4 and CD8 antibodies were both included in the F101.01-positive population, whereas CD16-positive natural killer cells (NK), B cells (CD19 and CD20......), and myeloid cells (CD13 and CD33) were excluded. The target antigen of F101.01 co-modulated with the CD3-defined antigen (T3) and the TCR recognized by the MoAb WT-31. CD3 antibody and WT-31 both blocked binding of F101.01. F101.01 precipitated the TCR-T3 complex from lysates of 125I-labelled peripheral blood...

  8. A Structured Approach for Reviewing Architecture Documentation

    Science.gov (United States)

    2009-12-01

    as those found in ISO 12207 [ ISO /IEC 12207 :2008] (for software engineering), ISO 15288 [ ISO /IEC 15288:2008] (for systems engineering), the Rational...Open Distributed Processing - Reference Model: Foundations ( ISO /IEC 10746-2). 1996. [ ISO /IEC 12207 :2008] International Organization for...Standardization & International Electrotechnical Commission. Sys- tems and software engineering – Software life cycle processes ( ISO /IEC 12207 ). 2008. [ ISO

  9. Reliability Validation and Improvement Framework

    Science.gov (United States)

    2012-11-01

    systems life cycle ( ISO /IEC 15288) and for the software life cycle ( ISO /IEC 12207 )[ ISO /IEC 2008a, 2008b] • revision of recommended practice for...Standardization/International Electrotechnical Commission. ISO /IEC 12207 : 2008 Systems and Software Engineering–System Life Cycle Processes. 2008. Available...the Capability Maturity Model Integration® (CMMI®), MIL-STD-882, SAE ARP4754, SAE ARP4761, DO-178B, DO-254, UK 00-56, IEC/ ISO 15026, IEC 61508, and

  10. Phase Transformation Behavior of Medium Manganese Steels with 3 Wt Pct Aluminum and 3 Wt Pct Silicon During Intercritical Annealing

    Science.gov (United States)

    Sun, Binhan; Fazeli, Fateh; Scott, Colin; Yue, Stephen

    2016-10-01

    Medium manganese steels alloyed with sufficient aluminum and silicon amounts contain high fractions of retained austenite adjustable to various transformation-induced plasticity/twinning-induced plasticity effects, in addition to a reduced density suitable for lightweight vehicle body-in-white assemblies. Two hot rolled medium manganese steels containing 3 wt pct aluminum and 3 wt pct silicon were subjected to different annealing treatments in the present study. The evolution of the microstructure in terms of austenite transformation upon reheating and the subsequent austenite decomposition during quenching was investigated. Manganese content of the steels prevailed the microstructural response. The microstructure of the leaner alloy with 7 wt pct Mn (7Mn) was substantially influenced by the annealing temperature, including the variation of phase constituents, the morphology and composition of intercritical austenite, the Ms temperature and the retained austenite fraction. In contrast, the richer variant 10 wt pct Mn steel (10Mn) exhibited a substantially stable ferrite-austenite duplex phase microstructure containing a fixed amount of retained austenite which was found to be independent of the variations of intercritical annealing temperature. Austenite formation from hot band ferrite-pearlite/bainite mixtures was very rapid during annealing at 1273 K (1000 °C), regardless of Mn contents. Austenite growth was believed to be controlled at early stages by carbon diffusion following pearlite/bainite dissolution. The redistribution of Mn in ferrite and particularly in austenite at later stages was too subtle to result in a measureable change in austenite fraction. Further, the hot band microstructure of both steels contained a large fraction of coarse-grained δ-ferrite, which remained almost unchanged during intercritical annealing. A recently developed thermodynamic database was evaluated using the experimental data. The new database achieved a better agreement

  11. Analysis and design of the installation of a lightning rod in risk areas of atmospheric discharge according to the standards NFPA 70, NFPA 780 and IEC 62305

    International Nuclear Information System (INIS)

    Cordoba Alfaro, Marco

    2012-01-01

    The design, analysis of the installation and handling of electrical protections oriented to atmospheric discharge in specific locations of the north zone of Costa Rica, are focused. Related topics with the devices of protection against atmospheric discharge, definitions, types, uses and characteristics were developed. The regulations NFPA 70, NFPA 780 and IEC 62305 are studied for the analysis and design of the lightning rod. The standards are analyzed, according to the rules applied at specialized companies in the elaboration and installation of lightning rod, in order to determine if these are adequate and used in correctly shape . A report is made about the design of a lightning rod and preventive measures for areas with regular activity of atmospheric discharges. The different devices for the elaboration and installation of a lightning rod are investigated in order to later use and exploitation. The design for the implementation of a system of conventional lightning rod, type tips of Franklin, was realized at the Iglesia Catedral of Ciudad Quesada. The materials that were used in this type of lightning rod, have followed the regulation NFPA 780. Several approximate plans of the cathedral have been performed to appreciate good the design, both in 2D as in 3D; these allow a better panorama of the installation. The distance between devices has been fundamental to take into account in the design of a system of lightning rod, as it marks an important difference between the area to protect and areas that may be exposed to an atmospheric discharge. The rule NFPA 780 has been established that to design the location of the lightning captors can use the rolling sphere method, also has marked the requirements of the downspouts systems and grounding systems. Before locating a lightning protection system it is important to be informed of the principal characteristics of the area to be protected; as on several occasions, the particularities of the selected area have

  12. 78 FR 7939 - Energy Conservation Program: Test Procedures for Microwave Ovens (Active Mode)

    Science.gov (United States)

    2013-02-04

    ...--Measurement of standby power,'' Edition 2.0 2011-01 (IEC Standard 62301 (Second Edition)) for measuring... cooking mode, plus the sum of the product of the average standby mode and off mode power consumption and... usage habits for microwave ovens.\\5\\ The survey collected data from 2258 households on the typical cycle...

  13. CIEMAT external dosimetry service: ISO/IEC 17025 accreditation and 3 y of operational experience as an accredited laboratory

    International Nuclear Information System (INIS)

    Romero, A.M.; Rodriguez, R.; Lopez, J.L.; Martin, R.; Benavente, J.F.

    2016-01-01

    In 2008, the CIEMAT Radiation Dosimetry Service decided to implement a quality management system, in accordance with established requirements, in order to achieve ISO/IEC 17025 accreditation. Although the Service comprises the approved individual monitoring services of both external and internal radiation, this paper is specific to the actions taken by the External Dosimetry Service, including personal and environmental dosimetry laboratories, to gain accreditation and the reflections of 3 y of operational experience as an accredited laboratory. (authors)

  14. Air Force Space Command. Space and Missile Systems Center Standard. Configuration Management

    Science.gov (United States)

    2008-06-13

    Engineering Drawing Practices IEEE STD 610.12 Glossary of Software Engineering Terminology, September 28,1990 ISO /IEC 12207 Software Life...item, regardless of media, formally designated and fixed at a specific time during the configuration item’s life cycle. (Source: ISO /IEC 12207

  15. INCITS W1.1 development update: appearance-based image quality standards for printers

    Science.gov (United States)

    Zeise, Eric K.; Rasmussen, D. René; Ng, Yee S.; Dalal, Edul; McCarthy, Ann; Williams, Don

    2008-01-01

    In September 2000, INCITS W1 (the U.S. representative of ISO/IEC JTC1/SC28, the standardization committee for office equipment) was chartered to develop an appearance-based image quality standard. (1),(2) The resulting W1.1 project is based on a proposal (3) that perceived image quality can be described by a small set of broad-based attributes. There are currently six ad hoc teams, each working towards the development of standards for evaluation of perceptual image quality of color printers for one or more of these image quality attributes. This paper summarizes the work in progress of the teams addressing the attributes of Macro-Uniformity, Colour Rendition, Gloss & Gloss Uniformity, Text & Line Quality and Effective Resolution.

  16. Characterization and property evaluation of U–15 wt%Pu alloy for fast reactor

    International Nuclear Information System (INIS)

    Kaity, Santu; Banerjee, Joydipta; Ravi, K.; Keswani, R.; Kutty, T.R.G.; Kumar, Arun; Prasad, G.J.

    2013-01-01

    The characterization and high temperature behaviour of U–15 wt%Pu alloy has been investigated in this study for the first time. U–15 wt%Pu alloy sample for this study was prepared by following melting and casting route. Microstructural characterization of the alloy was carried out by XRD and optical microscopy. The thermophysical properties like phase transition temperatures, coefficient of thermal expansion and hot hardness of the above alloy were determined. Eutectic temperature between T91 and U–15 wt%Pu was established. Apart from that, the fuel–cladding chemical compatibility of U–15 wt%Pu alloy with T91 grade steel was studied by diffusion couple experiment

  17. 22 CFR 231.01 - Purpose.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Purpose. 231.01 Section 231.01 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ARAB REPUBLIC OF EGYPT LOAN GUARANTEES ISSUED UNDER THE EMERGENCY WARTIME SUPPLEMENTAL APPROPRIATIONS ACT OF 2003, PUBLIC LAW 108-11-STANDARD TERMS AND CONDITIONS...

  18. Standards and guidelines applicable for the validation of programmable automation systems

    International Nuclear Information System (INIS)

    Haapanen, P.; Maskuniitty, M.

    1993-02-01

    The validation of programmable automation system for an application important to safety in a nuclear power plant requires a comprehensive view about the system quality and reliability. One central point is to get assured that proper international guidelines and standards have been followed in the design, construction and maintenance of the system. The study was directed to locate international standards and guidelines which can support the validation of programmable systems and to evaluate their applicability for the validation of systems on different levels of requirement during their life cycle. The publication reviews the most important international standards (IAEA, ISO, IEC, IEEE) and their basic principles both for system and application program. Several nuclear standards, which have drawn the main attention, and some general programmable automation standards have been examined. In addition one practical automation system has been examined in order to find essential questions. Based on these studies a set of important items for the qualification have been identified

  19. Implementation of quality standards in an individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Hyvoenen, H.; Vartiainen, E

    2001-07-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  20. Implementation of quality standards in an individual monitoring service

    International Nuclear Information System (INIS)

    Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    In this paper the implementation of a quality system to the procedures of an individual monitoring service (IMS) is described from the practical perspective. The IMS of the Radiation and Nuclear Safety Authority (STUK) is used as an example. The IMS of STUK monitors about 8500 persons mainly working in hospitals, industry and research centres. The current thermoluminescence dosemeter (TLD) system was introduced in 1992 and the whole service changed to TLDs in 1995. The quality system compatible with the quality standards was introduced in 1999. An application for accreditation to full EN45001 and ISO/IEC Guide 25 was made in December 1999, accreditation was achieved in August 2000 by the Finnish Accreditation Service (FINAS). The considerations needed for the quality system to fulfil the requirements of the quality standards are reported. (author)

  1. Hydro-abrasive erosion on coated Pelton runners: Partial calibration of the IEC model based on measurements in HPP Fieschertal

    Science.gov (United States)

    Felix, D.; Abgottspon, A.; Albayrak, I.; Boes, R. M.

    2016-11-01

    At medium- and high-head hydropower plants (HPPs) on sediment-laden rivers, hydro-abrasive erosion on hydraulic turbines is a major economic issue. For optimization of such HPPs, there is an interest in equations to predict erosion depths. Such a semi-empirical equation suitable for engineering practice is proposed in the relevant guideline of the International Electrotechnical Commission (IEC 62364). However, for Pelton turbines no numerical values of the model's calibration parameters have been available yet. In the scope of a research project at the high-head HPP Fieschertal, Switzerland, the particle load and the erosion on the buckets of two hard-coated 32 MW-Pelton runners have been measured since 2012. Based on three years of field data, the numerical values of a group of calibration parameters of the IEC erosion model were determined for five application cases: (i) reduction of splitter height, (ii) increase of splitter width and (iii) increase of cut-out depth due to erosion of mainly base material, as well as erosion of coating on (iv) the splitter crests and (v) inside the buckets. Further laboratory and field investigations are recommended to quantify the effects of individual parameters as well as to improve, generalize and validate erosion models for uncoated and coated Pelton turbines.

  2. Interlaboratory Study (ILS) for F 548-01, The Standard Test Method for Intensity of Scratches on Aerospace Transparent Plastics

    National Research Council Canada - National Science Library

    Pinkus, Alan

    2003-01-01

    ...) as outlined in ASTM E 691. This report, which conforms to the ILS reporting format required by ASTM, describes the study that was conducted for ASTM test standard F 548-01, Intensity of Scratches on Aerospace Transparent Plastics...

  3. Proposal and Evaluation of Subordinate Standard Solar Irradiance Spectra: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wilbert, Stefan [German Aerospace Center (DLR); Jessen, Wilko [German Aerospace Center (DLR); Gueymard, Chris [Solar Consulting Services; Polo, Jesus [CIEMAT; Bian, Zeqiang [China Meteorological Administration; Driesse, Anton [Photovoltaic Performance Labs; Marzo, Aitor [University of Antofagasta; Armstrong, Peter [Masdar Institute of Science & Technology; Vignola, Frank [University of Oregon; Ramirez, Lourdes [CIEMAT

    2018-04-12

    This paper introduces a concept for global tilted irradiance (GTI) subordinate standard spectra to supplement the current standard spectra used in solar photovoltaic applications as defined in ASTM G173 and IEC60904. The proposed subordinate standard spectra correspond to atmospheric conditions and tilt angles that depart significantly from the main standard spectrum, and they can be used to more accurately represent various local conditions. For the definition of subordinate standard spectra cases with an elevation 1.5 km above sea level, the question arises whether the air mass should be calculated including a pressure correction or not. This study focuses on the impact of air mass used in standard spectra, and it uses data from 29 locations to examine which air mass is most appropriate for GTI and direct normal irradiance (DNI) spectra. Overall, it is found that the pressure-corrected air mass of 1.5 is most appropriate for DNI spectra. For GTI, a non-pressure-corrected air mass of 1.5 was found to be more appropriate.

  4. A Strategy for Improved System Assurance

    Science.gov (United States)

    2007-06-20

    Quality (Measurements Life Cycle Safety, Security & Others) ISO /IEC 12207 * Software Life Cycle Processes ISO 9001 Quality Management System...14598 Software Product Evaluation Related ISO /IEC 90003 Guidelines for the Application of ISO 9001:2000 to Computer Software IEEE 12207 Industry...Implementation of International Standard ISO /IEC 12207 IEEE 1220 Standard for Application and Management of the System Engineering Process Use in

  5. Correlation study on waist circumference-triglyceride (WT) index and coronary artery scores in patients with coronary heart disease.

    Science.gov (United States)

    Yang, R-F; Liu, X-Y; Lin, Z; Zhang, G

    2015-01-01

    Coronary disease is analyzed through common lipid profiles, but these analyses fail to account for residual risk due to abdominal weight and elevated TG levels. We aimed to investigate the relationship between the waist circumference × triglyceride index (WT index) and the Coronary Artery Score (CAS) in patients with coronary heart disease. 346 patients in our Cardiology Department were recruited from September 2007 to August 2011 and divided into two groups according to whether the patients presented with metabolic syndrome. We performed coronary angiography using the standard Judkins method. The severity of coronary artery stenosis and the CAS were calculated and analyzed with a computerized quantitative analysis system. The signs index, which includes the body mass index (BMI), waist circumference, hip circumference, waist-hip-ratio, and waist-height-ratio, the blood glucose and blood lipid index of all the patients were collected and used to calculate the WT index (waist circumference x triglyceride index. We performed a correlative analysis with age, gender, body mass index, blood glucose and blood lipid, blood pressure and other risk indicators of all patients as the dependent variables and the CAS as the independent variable. We show that the CAS is positively correlated to the WT index. Several lipid profiles and waist circumference were significantly associated with the CAS. The WT index is correlated to the CAS and is a good predictor for the development of coronary artery disease; it can be applied in the clinic for early intervention in populations at risk for coronary heart disease.

  6. New aspects from legislation, guidelines and safety standards for MRI

    International Nuclear Information System (INIS)

    Muehlenweg, M.; Schaefers, G.; Trattnig, S.

    2015-01-01

    Many aspects of magnetic resonance (MR) operation are not directly regulated by law but in standards, guidelines and the operating instructions of the MR scanner. The mandatory contents of the operating instructions are regulated in a central standard of the International Electrotechnical Commission (IEC) 60601-2-33. In this standard, the application of static magnetic fields in MRI up to 8 Tesla (T) in the clinical routine (first level controlled mode) has recently been approved. Furthermore, the equally necessary CE certification of ultra-high field scanners (7-8 T) in Europe is expected for future devices. The existing installations will not be automatically certified but will retain their experimental status. The current extension of IEC 60601-2-33 introduces a new add-on option, the so-called fixed parameter option (FPO). This option might also be switched on in addition to the established operating modes and defines a fixed device constellation and certain parameters of the energy output of MR scanners designed to simplify the testing of patients with implants in the future. The employment of pregnant workers in an MRI environment is still not generally regulated in Europe. In parts of Germany and Austria pregnant and lactating employees were prohibited from working in the MR control zone (0.5 mT) in 2014. This is based on the mostly unresolved question of the applicability of limits for employees (exposure of extremities to static magnetic fields up to 8 T allowed) or the thresholds for the general population (maximum 400 mT). According to the European Society of Urogenital Radiology (ESUR), the discarding of breast milk after i.v. administration of gadolinium-based contrast agents in the case of a breastfeeding woman is only recommended when using contrast agents in the nephrogenic systemic fibrosis (NSF) high-risk category. (orig.) [de

  7. Implementing PAT with Standards

    Science.gov (United States)

    Chandramohan, Laakshmana Sabari; Doolla, Suryanarayana; Khaparde, S. A.

    2016-02-01

    Perform Achieve Trade (PAT) is a market-based incentive mechanism to promote energy efficiency. The purpose of this work is to address the challenges inherent to inconsistent representation of business processes, and interoperability issues in PAT like cap-and-trade mechanisms especially when scaled. Studies by various agencies have highlighted that as the mechanism evolves including more industrial sectors and industries in its ambit, implementation will become more challenging. This paper analyses the major needs of PAT (namely tracking, monitoring, auditing & verifying energy-saving reports, and providing technical support & guidance to stakeholders); and how the aforesaid reasons affect them. Though current technologies can handle these challenges to an extent, standardization activities for implementation have been scanty for PAT and this work attempts to evolve them. The inconsistent modification of business processes, rules, and procedures across stakeholders, and interoperability among heterogeneous systems are addressed. This paper proposes the adoption of specifically two standards into PAT, namely Business Process Model and Notation for maintaining consistency in business process modelling, and Common Information Model (IEC 61970, 61968, 62325 combined) for information exchange. Detailed architecture and organization of these adoptions are reported. The work can be used by PAT implementing agencies, stakeholders, and standardization bodies.

  8. Knowledge, attitude, behaviour and practices (KABP) of the community and resultant IEC leading to behaviour change about dengue in Jodhpur City, Rajasthan.

    Science.gov (United States)

    2016-01-01

    In recent years dengue has been witnessed as an emerging public health problem. Therefore, the present study was undertaken in order to assess the knowledge, attitude, behaviour and practices (KABP) adopted by the society for its control and prevention. The changes in behaviour of community after imparting health education were also recorded to determine the effectiveness of information, education and communication (IEC) for dengue prevention and control in Jodhpur City of Rajasthan, India. A threefold study was conducted in Jodhpur City regarding KABP about dengue fever amongst the community. Out of 106 cases of dengue reported from Jodhpur City in the year 2008, only 20 households (HHs) could be located. Therefore, nine HHs around one dengue positive household were selected so as to cover the sample size of 200 HHs for eliciting information through structured recorded interview-schedule. Health education as provided through audiovisuals and group discussion etc. and resultant change in KABP was recorded again through interview of respondents from 100 households. Prevention from dengue mosquito bites through mats and liquid vaporizer was known to 32 and 22% HHs respectively. Inhabitants of 87% HHs preferred to visit private health facility, 85% of HHs were not aware about the symptoms of dengue, while74% HHs stated that dengue mosquito breeds in dirty water. Awareness about source of mosquito breeding and source reduction was found to be very poor, i.e. 3 and 13% which improved to 78 and 88% respectively after undertaking IEC activities. Being urban area, the economic condition and education level were somewhat similar and satisfactory in Jodhpur City. IEC resulted in significant improvement in knowledge about transmission, breeding habitats of mosquito transmitting dengue, source reduction and health treatment seeking behaviour at government facility. Through such mass awareness programmes in the communities, desired results in prevention and control of dengue

  9. The American Association for Laboratory Accreditation

    Science.gov (United States)

    2011-03-28

    ISO / IEC 17025 ...Information Technology A2LA DoD ELAP Program n All labs are assessed to ISO / IEC 17025 :2005 as the base standard. n In addition, the requirements of 2003...n Inspection Body Accreditation ( ISO / IEC 17020) n Proficiency Testing Providers ( ISO / IEC 17043) n Reference Materials Producers ( ISO Guide

  10. Screening Samples for Arsenic by Inductively Coupled Plasma-Mass Spectrometry for Treaty Samples

    Science.gov (United States)

    2014-02-01

    quality system in accordance with International Organization for Standardization/International Electrotechnical Commission ( ISO / IEC ) 17025 :2005...plasma-mass spectrometry ISO / IEC International Organization for Standardization/International Electrotechnical Commission L lewisite MDL method

  11. Progress on standardization and automation in software development on W7X

    International Nuclear Information System (INIS)

    Kühner, Georg; Bluhm, Torsten; Heimann, Peter; Hennig, Christine; Kroiss, Hugo; Krom, Jon; Laqua, Heike; Lewerentz, Marc; Maier, Josef; Schacht, Jörg; Spring, Anett; Werner, Andreas; Zilker, Manfred

    2012-01-01

    Highlights: ► For W7X software development the use of ISO/IEC15504-5 is further extended. ► The standard provides a basis to manage software multi-projects for a large system project. ► Adoption of a scrum-like management allows for quick reaction on priority changes. ► A high degree of software build automation allows for quick responses to user requests. ► It provides additional resources to concentrate work on product quality (ISO/IEC 25000). - Abstract: For a complex experiment like W7X being subject to changes all along its projected lifetime the advantages of a formalized software development method have already been stated. Quality standards like ISO/IEC-12207 provide a guideline for structuring of development work and improving process and product quality. A considerable number of tools has emerged supporting and automating parts of development work. On W7X progress has been made during the last years in exploiting the benefit of automation and management during software development: –Continuous build, integration and automated test of software artefacts. ∘Syntax checks and code quality metrics. ∘Documentation generation. ∘Feedback for developers by temporal statistics. –Versioned repository for build products (libraries, executables). –Separate snapshot and release repositories and automatic deployment. –Semi-automatic provisioning of applications. –Feedback from testers and feature requests by ticket system. This toolset is working efficiently and allows the team to concentrate on development. The activity there is presently focused on increasing the quality of the existing software to become a dependable product. Testing of single functions and qualities must be simplified. So a restructuring is underway which relies more on small, individually testable components with standardized interfaces providing the capability to construct arbitrary function aggregates for dedicated tests of quality attributes as availability, reliability

  12. Progress on standardization and automation in software development on W7X

    Energy Technology Data Exchange (ETDEWEB)

    Kuehner, Georg, E-mail: kuehner@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Bluhm, Torsten [Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Heimann, Peter [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstrasse 2, D-85748 Garching (Germany); Hennig, Christine [Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Kroiss, Hugo [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstrasse 2, D-85748 Garching (Germany); Krom, Jon; Laqua, Heike; Lewerentz, Marc [Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Maier, Josef [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstrasse 2, D-85748 Garching (Germany); Schacht, Joerg; Spring, Anett; Werner, Andreas [Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstrasse 1, D-17491 Greifswald (Germany); Zilker, Manfred [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstrasse 2, D-85748 Garching (Germany)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer For W7X software development the use of ISO/IEC15504-5 is further extended. Black-Right-Pointing-Pointer The standard provides a basis to manage software multi-projects for a large system project. Black-Right-Pointing-Pointer Adoption of a scrum-like management allows for quick reaction on priority changes. Black-Right-Pointing-Pointer A high degree of software build automation allows for quick responses to user requests. Black-Right-Pointing-Pointer It provides additional resources to concentrate work on product quality (ISO/IEC 25000). - Abstract: For a complex experiment like W7X being subject to changes all along its projected lifetime the advantages of a formalized software development method have already been stated. Quality standards like ISO/IEC-12207 provide a guideline for structuring of development work and improving process and product quality. A considerable number of tools has emerged supporting and automating parts of development work. On W7X progress has been made during the last years in exploiting the benefit of automation and management during software development: -Continuous build, integration and automated test of software artefacts. Ring-Operator Syntax checks and code quality metrics. Ring-Operator Documentation generation. Ring-Operator Feedback for developers by temporal statistics. -Versioned repository for build products (libraries, executables). -Separate snapshot and release repositories and automatic deployment. -Semi-automatic provisioning of applications. -Feedback from testers and feature requests by ticket system. This toolset is working efficiently and allows the team to concentrate on development. The activity there is presently focused on increasing the quality of the existing software to become a dependable product. Testing of single functions and qualities must be simplified. So a restructuring is underway which relies more on small, individually testable components with standardized

  13. Grid impact of variable-speed wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Aa [Chalmers Univ. of Technology, Dept. of Electric Power Engineering, Goeteborg (Sweden); Soerensen, P [Risoe National Lab., Roskilde (Denmark); Santjer, F [German Wind Energy Inst., DEWI, Wilhelmshaven (Germany)

    1999-03-01

    In this paper the power quality of variable-speed wind turbines equipped with forced-commutated inverters is investigated. Measurements have been taken on the same type of variable-speed wind turbines in Germany and Sweden. The measurements have been analysed according to existing IEC standards. Special attention has been paid to the aggregation of several wind turbines on flicker emission and harmonics. The aggregation has been compared with the summation laws used in the draft IEC 61400-21 `Power Quality Requirements for Grid Connected wind turbines`. The methods for calculating and summing flicker proposed by IEC Standards are reliable. Harmonics and inter-harmonics are treated in IEC 61000-4-7 and IEC 61000-3-6. The methods for summing harmonics and inter-harmonics in IEC 61000-3-6 are applicable to wind turbines. In order to obtain a correct magnitude of the frequency components, the use of a well-defined window width, according to IEC 61000-4-7 Amendment 1 is of a great importance. (au)

  14. Mechanical, dynamical and thermodynamic properties of Al-3wt%Mg from first principles

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Rong [Chongqing Jiaotong Univ., Chongqing (China). College of Materials Science and Engineering; Tang, Bin [Chongqing City Management College, Chongqing (China). Inst. of Finance and Trade; Gao, Tao [Sichuan Univ., Chengdu (China). Inst. of Atomic and Molecular Physics

    2017-09-01

    The mechanical, dynamical and thermodynamic properties of Al-3wt%Mg have been investigated using the first-principles method. The calculated structural parameter is in good agreement with previous works. Results for the elastic modulus, stress-strain relationships, ideal tensile and shear strengths are presented. Al-3wt%Mg is found to have larger moduli and higher strengths than Al, which is consistent with its exploitation in Al precipitate-hardening mechanisms. The partial density of states (PDOS) show that the partly covalent-like bonding through Al p-Mg s hybridization is the origin of excellent mechanical properties of Al-3wt%Mg. The phonon dispersion curves indicate that Al-3wt%Mg is dynamically stable at ambient pressure and 0 K. Furthermore, the Helmholtz free energy ΔF, the entropy S, the constant-volume specific heat C{sub V} and the phonon contribution to the internal energy ΔE are predicted using the phonon density of states. We expect that our work can provide useful guidance to help with the performance of Al-3wt%Mg.

  15. Mechanical, dynamical and thermodynamic properties of Al-3wt%Mg from first principles

    International Nuclear Information System (INIS)

    Yang, Rong; Tang, Bin; Gao, Tao

    2017-01-01

    The mechanical, dynamical and thermodynamic properties of Al-3wt%Mg have been investigated using the first-principles method. The calculated structural parameter is in good agreement with previous works. Results for the elastic modulus, stress-strain relationships, ideal tensile and shear strengths are presented. Al-3wt%Mg is found to have larger moduli and higher strengths than Al, which is consistent with its exploitation in Al precipitate-hardening mechanisms. The partial density of states (PDOS) show that the partly covalent-like bonding through Al p-Mg s hybridization is the origin of excellent mechanical properties of Al-3wt%Mg. The phonon dispersion curves indicate that Al-3wt%Mg is dynamically stable at ambient pressure and 0 K. Furthermore, the Helmholtz free energy ΔF, the entropy S, the constant-volume specific heat C_V and the phonon contribution to the internal energy ΔE are predicted using the phonon density of states. We expect that our work can provide useful guidance to help with the performance of Al-3wt%Mg.

  16. CSA guide to Canadian wind turbine codes and standards

    International Nuclear Information System (INIS)

    2008-01-01

    The Canadian wind energy sector has become one of the fastest-growing wind energy markets in the world. Growth of the industry has been supported by various government agencies. However, many projects have experienced cost over-runs or cancellations as a result of unclear regulatory requirements, and wind energy developers are currently subject to a variety of approval processes involving several different authorities. This Canadian Standards Association (CSA) guide provided general information on codes and standards related to the design, approval, installation, operation, and maintenance of wind turbines in Canada. CSA codes and standards were developed by considering 5 new standards adopted by the International Electrotechnical Commission (IEC) Technical Committee on Wind Turbines. The standards described in this document related to acoustic noise measurement techniques; power performance measurements of electricity-producing wind turbines; lightning protection for wind turbine generator systems; design requirements for turbines; and design requirements for small wind turbines. The guide addressed specific subject areas related to the development of wind energy projects that involve formal or regulatory approval processes. Subject areas included issues related to safety, environmental design considerations, site selection, and mechanical systems. Information on associated standards and codes was also included

  17. Influence of ZnO nano-particles addition on thermal analysis, microstructure evolution and tensile behavior of Sn–5.0 wt% Sb–0.5 wt% Cu lead-free solder alloy

    Energy Technology Data Exchange (ETDEWEB)

    Fouda, A.N., E-mail: alynabieh@yahoo.com [Physics Department, Faculty of Science, Suez-Canal University, 41522 Ismailia (Egypt); Eid, E.A., E-mail: dr_eid_hti@yahoo.com [Basic Science Department, Higher Technological Institute, 44629 10th of Ramadan City (Egypt)

    2015-04-24

    Sn–5 wt%Sb–0.5 wt%Cu (plain SSC505) and Sn–5 wt%Sb–0.5 wt%Cu–0.5 wt% ZnO (SSC-ZnO) composite solder alloys have been studied. The variation in thermal behavior, microstructure and tensile characteristics associated with mixing of 0.5 wt% ZnO nano-metric particles to plain SSC505 solder were investigated. A slight increment in the melting temperature [ΔT{sub m}=0.89 °C] was recorded using differential scanning calorimetry (DSC) after addition of ZnO. X-Ray diffraction (XRD) analysis confirmed the existence of β-Sn, SbSn and Cu{sub 6}Sn{sub 5} intermetallic compounds (IMCs) beside some of ZnO planes in SSC-ZnO composite solder. Field emission scanning electronic microscope (FE-SEM) investigation of SSC-ZnO composite solder revealed a homogenous uniform distribution, size refinement of IMCs and β-Sn grains. Addition of ZnO nano-metric particles into the plain SSC505 enhanced the yield stress σ{sub YS} by ~12% and improved the ultimate tensile strength σ{sub UTS} by ~13%. In addition, adding ZnO nano-metric particles was found to be effective for reducing ductility by ~43% of the plain solder due to the refinement of β-Sn grains within SSC-ZnO composite solder. - Highlights: • Melting point of SSC505-ZnO composite solder is slightly increased by 0.89 {sup ο}C compared with the plain SSC505 solder. • XRD and EDX analysis reflect the presence of SbSn, Cu{sub 6}Sn{sub 5} IMCs. • EF-SEM images of SSC-ZnO composite solder revealed homogenous uniform distribution of β-Sn grains and fine IMC particles. • A detectable improvement in the Young modulus, ultimate tensile strength and yield strength were observed after addition of 0.5 wt% ZnO nano-metric particles.

  18. Printing system perceptual-based gloss and gloss uniformity standard (INCITS W1.1)

    Science.gov (United States)

    Ng, Yee S.; Cui, Luke C.; Kuo, Chung-Hui; Maggard, Eric; Mashtare, Dale; Morris, Peter; Viola, Michael

    2003-12-01

    To address the standarization issues of perceptually based image quality for printing systems, ISO/IEC JTC1/SC28, the standarization committee for office equipment charactered the W1.1 project with the responsibiltiy of drafting a proposal for an international standard for the evaluation of printed image quality. One of the W1.1 task teams is charactered to address the issue of 'Gloss and Gloss Uniformity". This paper summarizes the current status and technical progress of this ad hoc team in 2003.

  19. Augmented internalisation of ferroportin to late endosomes impairs iron uptake by enterocyte-like IEC-6 cells.

    Science.gov (United States)

    Oates, Phillip S; Thomas, Carla

    2005-08-01

    Absorption of iron occurs by duodenal enterocytes, involving uptake by the divalent metal transporter-1 (DMT1) and release by ferroportin. Ferroportin responds to the hepatocyte-produced 25-amino-acid-peptide hepcidin-25 by undergoing internalisation to late endosomes that impair iron release. Ferroportin is also expressed on the apical membrane of polarised Caco-2 cells, rat intestinal cells and in IEC-6 cells (an intestinal epithelial cell line). A blocking antibody to ferroportin also impairs the uptake, but not the release, of iron. In this study IEC-6 cells were used to study the mechanism of impairment or recovery from impairment produced by the blocking antibody and the fate of DMT1 and ferroportin. Uptake of 1 muM Fe(II) was studied by adding the antibody from time 0 and after adding or removing the antibody once a steady state had been reached. Surface binding, maximum iron transport rate V(max) and transporter affinity (K(m)) were measured after impairment of iron uptake. Ferroportin and DMT1 distribution were assessed by immunofluorescence microscopy. Antibody-mediated impairment, or recovery from impairment, of Fe(II) uptake occurred within minutes. Impairment was lost when the antibody was combined with the immunizing peptide. DMT1 and ferroportin undergo internalisation to late endosomes and, in the presence of the antibody, augmented internalisation of DMT1 and ferroportin caused swelling of late endosomes. Surface binding of Fe(II) and iron transport V(max) were reduced by 50%, indicating that the antibody removed membrane-bound DMT1. The ferroportin antibody induced rapid turnover of membrane ferroportin and DMT1 and its internalisation to late endosomes, resulting in impaired Fe(II) uptake.

  20. Treatise on water hammer in hydropower standards and guidelines

    International Nuclear Information System (INIS)

    Bergant, A; Mazij, J; Karney, B; Pejović, S

    2014-01-01

    This paper reviews critical water hammer parameters as they are presented in official hydropower standards and guidelines. A particular emphasize is given to a number of IEC standards and guidelines that are used worldwide. The paper critically assesses water hammer control strategies including operational scenarios (closing and opening laws), surge control devices (surge tank, pressure regulating valve, flywheel, etc.), redesign of the water conveyance system components (tunnel, penstock), or limitation of operating conditions (limited operating range) that are variably covered in standards and guidelines. Little information is given on industrial water hammer models and solutions elsewhere. These are briefly introduced and discussed in the light of capability (simple versus complex systems), availability of expertise (in house and/or commercial) and uncertainty. The paper concludes with an interesting water hammer case study referencing the rules and recommendations from existing hydropower standards and guidelines in a view of effective water hammer control. Recommendations are given for further work on development of a special guideline on water hammer (hydraulic transients) in hydropower plants

  1. Treatise on water hammer in hydropower standards and guidelines

    Science.gov (United States)

    Bergant, A.; Karney, B.; Pejović, S.; Mazij, J.

    2014-03-01

    This paper reviews critical water hammer parameters as they are presented in official hydropower standards and guidelines. A particular emphasize is given to a number of IEC standards and guidelines that are used worldwide. The paper critically assesses water hammer control strategies including operational scenarios (closing and opening laws), surge control devices (surge tank, pressure regulating valve, flywheel, etc.), redesign of the water conveyance system components (tunnel, penstock), or limitation of operating conditions (limited operating range) that are variably covered in standards and guidelines. Little information is given on industrial water hammer models and solutions elsewhere. These are briefly introduced and discussed in the light of capability (simple versus complex systems), availability of expertise (in house and/or commercial) and uncertainty. The paper concludes with an interesting water hammer case study referencing the rules and recommendations from existing hydropower standards and guidelines in a view of effective water hammer control. Recommendations are given for further work on development of a special guideline on water hammer (hydraulic transients) in hydropower plants.

  2. The International Standards for Solar Thermal Collectors and Components as a Medium of Quality Assurance

    International Nuclear Information System (INIS)

    Alkishriwi, Nouri; Schorn, Christian A.; Theis, Danjana

    2014-01-01

    Within this publication a detailed overview about the national and international solal't1lel1nai standards is made. The various tests are described and a cross reference list for comparing the different standards is given. Moreover a certification model is presented and the advantage of third party assessment is carried out. The requirement for a solar thermal test laboratory to conduct independent third party assessment by means of an ISO/IEC17065 accreditation is given. Finally the concept of a quality system for solar thermal markets is explained and major advantages are outlined. Solar thermal systems and their components are described in various national and international standards. In Europe the standard EN12975 defines the regulations and requirements for solar thermal collectors. The standard EN12976 is established for the evaluation of factory made solar thermal systems. The EN12977 is the state of the art standard for the evaluation of custom build systems. Nowadays in Libya the standard ISO9806 for solar collectors and the standard ISO9459 for domestic water heating systems define the regulations and requirements for solar thermal collectors and systems. In the meanwhile, empowered Center for Renewable Energy and Energy Efficiency Certification Body is under construction. This body is working now to set the minimum requirements of the testing facilities of solar thermal systems. The international standard for collector testing is the ISO9806 and the standard ISO9459 Part 2, 4, 5 for domestic water heating systems. Within the year 2013 a revision of the ISO9806 will be published and, for the first time, a consistent harmonized standard for the main solar thermal markets will be set in force. Besides the various standards for solar thermal products a meaningful element for the quality assurance and the customer protection is third party certification. Third party certification involves an independent assessment, declaring that specified requirements

  3. Effect of helium plasma gas flow rate on the properties of WC-12 wt.%Co coatings sprayed by atmospheric plasma

    Directory of Open Access Journals (Sweden)

    Mihailo R. Mrdak

    2014-06-01

    Full Text Available The cermet coatings of WC-12wt.%Co are extensively used to improve the wear resistance of a wide range of technical components. This paper analyses the influence of the plasma gas flow of helium on the microstructure and mechanical properties of WC-12wt.%Co coatings deposited by plasma spraying at atmospheric pressure (APS. In order to obtain homogeneous and denser coatings, three different flows of He ( 8 l/min., 16 l/min. and 32 l/min were used in the research. With the application of He, coatings achieved higher values of hardness due to less degradation of the primary WC carbides. The main goal was to deposit dense and homogeneous layers of WC-12wt.%Co coatings with improved wear resistance for different applications. The test results of the microstructure of the layers were evaluated under a light microscope. The analysis of the microstructure and the mechanical properties of the deposited layers was made in accordance with the standard of Pratt-Whitney. The morphology of the powder particles and the microstructure of the best coating was examined on the SEM (scanning electron microscope. The evaluation of the mechanical properties of the layers was done by applying the HV0.3 method for microhardness testing and by applying tensile testing to test the bond strength. The research has shown that the flow of He plasma gas significantly affects the microstructure, the mechanical properties and the structure of WC-12 wt.%Co coatings.

  4. IT Security Standards and Legal Metrology - Transfer and Validation

    Science.gov (United States)

    Thiel, F.; Hartmann, V.; Grottker, U.; Richter, D.

    2014-08-01

    Legal Metrology's requirements can be transferred into the IT security domain applying a generic set of standardized rules provided by the Common Criteria (ISO/IEC 15408). We will outline the transfer and cross validation of such an approach. As an example serves the integration of Legal Metrology's requirements into a recently developed Common Criteria based Protection Profile for a Smart Meter Gateway designed under the leadership of the Germany's Federal Office for Information Security. The requirements on utility meters laid down in the Measuring Instruments Directive (MID) are incorporated. A verification approach to check for meeting Legal Metrology's requirements by their interpretation through Common Criteria's generic requirements is also presented.

  5. Industrial Wireless Sensors: A User's Perspective on the Impact of Standards on Wide-spread Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Taft, Cyrus W. [Taft Engineering, Inc.; Manges, Wayne W [ORNL; Sorge, John N [Southern Company Services, Inc.

    2012-01-01

    The role of wireless sensing technologies in industrial instrumentation will undoubtedly become more important in the years ahead. . Deployment of such instrumentation in an industrial setting with its heightened security and robustness criteria hinges on user acceptance of verified performance as well as meeting cost requirements. Today, industrial users face many choices when specifying a wireless sensor network, including radio performance, battery life, interoperability, security, and standards compliance. The potential market for industrial wireless sensors is literally millions of wireless instruments and it is imperative that accurate information for applying the technology to real-world applications be available to the end-user so that they can make informed deployment decisions. The majority of industrial wireless automation designs now being deployed or being considered for deployment are based on three different standards . The HART Communications Foundation s WirelessHART (IEC 62591), the International Society of Automation s ISA100.11a, and the offering from the Industrial Wireless Alliance of China known as WIA-PA (IEC 62601). Aside from these industrial automation standards, users must also be cognizant of the underlying wireless network standards IEEE 802.11, IEEE 802.15.4, and IEEE 802.15.3a and their interactions with the three principal industrial automation protocols mentioned previously. The crucial questions being asked by end users revolve around sensor network performance, interoperability, reliability, and security. This paper will discuss potential wireless sensor applications in power plants, barriers to the acceptance of wireless technology, concerns related to standards, and provide an end user prospective on the issues affecting wide-spread deployment of wireless sensors. Finally, the authors conclude with a discussion of a recommended path forward including how standards organizations can better facilitate end user decision making and

  6. Risk Assessment References: Documented Literature Search

    Science.gov (United States)

    2012-10-01

    concepts specified in ISO /IEC 27001 and is designed to assist the satisfactory implementation of information security based on a risk management approach...Knowledge of the concepts, models, processes and terminologies described in ISO /IEC 27001 and ISO /IEC 27002 is important for a complete...Standardization ( ISO ). • Section 2.2: national standards for Canada and Australia/New Zealand. Note: Though most of the references in this section are

  7. Effect of Heat Treatments on Microstructures and Tensile Properties of Cu-3 wt%Ag-0.5 wt%Zr Alloy

    Science.gov (United States)

    Chen, Gang; Wang, ChuanJie; Zhang, Ying; Yi, Cen; Zhang, Peng

    2018-03-01

    The microstructures and tensile properties of Cu-3 wt%Ag-0.5 wt%Zr alloy sheets under different aging treatments are investigated in this research. As one kind of precipitate, Ag nanoparticles with coherent orientation relationship with matrix precipitate. However, after the peak-age point, most of Ag nanoparticles grow into short rod shape with the interface translating to semi-coherent, which leads to the lower strength of over-aging sample. The yield strength is estimated by considering solid solute, grain boundary and precipitation strengthening mechanisms. The result shows that the Ag precipitates provide the main strengthening role. Then a constitutive equation representing the evolution of dislocation density with plastic strain is built by considering work-hardening behavior coming from shearable and non-shearable precipitates which is mainly the particles containing Zr. The flow stress contributed by shearable particle hardening is higher than that of non-shearable one. Due to the coarsening of grain boundary precipitates and low rate of damage accumulation of these non-shearable particles, the micro-cracks nucleate easily at grain boundary which leads to intergranular fracture.

  8. ANALYSIS OF THE CHARACTERISTICS OF INTERNATIONAL STANDARD ALGORITHMS «LIGHTWEIGHT CRYPTOGRAPHY» – ISO/IEC 29192-3:2012

    Directory of Open Access Journals (Sweden)

    A. S. Poljakov

    2014-01-01

    Full Text Available The data on the characteristics of international standard algorithms «lightweight cryptography» while application in hardware implementation based on microchips of FPGA are provided. A compari-son of the characteristics of these algorithms with the characteristics of several widely-used standard encryption algorithms is made and possibilities of lightweight cryptography algorithms are evaluated.

  9. Biological bases of the maximum permissible exposure levels of the UK laser standard BS 4803 1983

    CERN Document Server

    MacKinlay, Alistair F

    1983-01-01

    The use of lasers has increased greatly over the past 15 years or so, to the extent that they are now used routinely in many occupational and public situations. There has been an increasing awareness of the potential hazards presented by lasers and substantial efforts have been made to formulate safety standards. In the UK the relevant Safety Standard is the British Standards Institution Standard BS 4803. This Standard was originally published in 1972 and a revision has recently been published (BS 4803: 1983). The revised standard has been developed using the American National Standards Institute Standard, ANSI Z136.1 (1973 onwards), as a model. In other countries, national standards have been similarly formulated, resulting in a large measure of international agreement through participation in the work of the International Electrotechnical Commission (IEC). The bases of laser safety standards are biophysical data on threshold injury effects, particularly on the retina, and the development of theoretical mode...

  10. Microstructure and adhesion strength of Sn-9Zn-1.5Ag-xBi (x = 0 wt% and 2 wt%)/Cu after electrochemical polarization in a 3.5 wt% NaCl solution

    Energy Technology Data Exchange (ETDEWEB)

    Li, W.-L. [Department of Mechanical Engineering, National Kaohsiung University of Applied Sciences, 415 Chien-Kung Road, Kaohsiung 80782, Taiwan (China); Institute of Nanotechnology and Microsystems Engineering, National Cheng Kung University, 1 Ta-Hsueh Road, Tainan 70101, Taiwan (China); Chen, Y.-R.; Chang, K.-M. [Department of Mechanical Engineering, National Kaohsiung University of Applied Sciences, 415 Chien-Kung Road, Kaohsiung 80782, Taiwan (China); Liu, C.-Y.; Hon, M.-H. [Department of Materials Science and Engineering, National Cheng Kung University, 1 Ta-Hsueh Road, Tainan 70101, Taiwan (China); Wang, M.-C. [Faculty of Fragrance and Cosmetics, Kaohsiung Medical University, 100 Shihchuan 1st Road, Kaohsiung 80728, Taiwan (China)], E-mail: mcwang@kmu.edu.tw

    2008-08-11

    The microstructure and adhesion strength of the Sn-9Zn-1.5Ag-xBi (x = 0 wt% and 2 wt%)/Cu interface after electrochemical polarization have been studied by X-ray diffraction (XRD), scanning electron microscopy (SEM) and pull-off testing. The equilibrium potentials of Sn-9Zn-1.5Ag/Cu and Sn-9Zn-1.5Ag-2Bi/Cu are -1.31 V{sub sce} and -1.22 V{sub sce}, respectively, indicating that Sn-9Zn-1.5Ag-2Bi/Cu has a better corrosion resistance than that of Sn-9Zn-1.5Ag/Cu. The intermetallic compounds of Cu{sub 6}Sn{sub 5}, Cu{sub 5}Zn{sub 8} and Ag{sub 3}Sn are formed at the soldered interface between the Sn-9Zn-1.5Ag-xBi solder alloy and the Cu substrate. The scallop-shaped Cu{sub 6}Sn{sub 5} is close to the Cu substrate and the scallop-shaped Cu{sub 5}Zn{sub 8} is found at the interface in the solder matrix after soldering at 250 deg. C for 10 s. The corrosion products are ZnCl{sub 2}, SnCl{sub 2} and ZnO. On the other hand, pits are also formed on the surface of both solder alloys. The interfacial adhesion strength of the Sn-9Zn-1.5Ag/Cu and Sn-9Zn-1.5Ag-2Bi/Cu decreases from 8.27 {+-} 0.56 MPa and 12.67 {+-} 0.45 MPa to 4.78 {+-} 0.45 MPa and 8.14 {+-} 0.38 MPa, respectively, after electrochemical polarization in a 3.5 wt% NaCl solution. The fracture path of the Sn-9Zn-1.5Ag-2Bi/Cu is along the solder alloy/ZnO and solder/Cu{sub 6}Sn{sub 5} interfaces.

  11. Hot drawn Fe–6.5 wt.%Si wires with good ductility

    International Nuclear Information System (INIS)

    Yang, W.; Li, H.; Yang, K.; Liang, Y.F.; Yang, J.; Ye, F.

    2014-01-01

    Highlights: • Fe–6.5wt%Si steel wire with diameter of 1.6 mm can be successfully obtained by hot drawing process. • The ductility of Fe–6.5wt%Si alloy can be improved significantly when it is fabricated in the form of wire. • The Dc magnetic property of Fe–6.5wt%Si steel wire 1.6 mm in diameter is excellent, which is close to that of 0.3 mm thick cold-rolling sheet. - Abstract: Fe–6.5 wt.%Si high silicon steel wires with a diameter of 1.6 mm are fabricated successfully by hot drawing. The high silicon steel wires show much better ductility than sheets. The tensile strength and elongation of the wires at the room temperature can reach 1.31 GPa and 1.4%, respectively. The tensile strength and elongation of the rolling sheet at the room temperature are 0.8 GPa and 0, respectively. The microstructure analyses show that the elongated grains after drawing and reduced ordering phases by deformation in the wires might contribute to its good ductility. Bs value of 1.437 T and Hc value of 16.96 A/m are obtained for the wire after proper heat treatment for the wires

  12. Analysis of a provider of proficiency testing by interlaboratory comparisons for dosimetry in function of guides ISO/IEC 43 and ILAC G13

    International Nuclear Information System (INIS)

    Lohr, J.; Zaretzky, Alba; Stefanic, Amalia M.; Saravi, M.

    2009-01-01

    The Ionising Radiation Dosimetry Group (CNEA) has participated of the last intercomparison scheme organized by EUROMET. This intercomparison was held starting 2005 until 2008.The objective of this paper is to analyze this Association as a proficiency test provider according to the ISO/IEC Guide 43 (1997) 'Proficiency testing by interlaboratory comparisons' and ILAC G13 Guide (2007) 'Guidelines for the Requirements for the Competence of Providers of Proficiency Testing Schemes'. The analysis of EURAMET (so called since 2007) as the provider of this dosimetric comparison was made taking into account the following sections of the ILAC G13 Guide: Conduct of proficiency testing schemes; Statistical design, Communication with participants and Reports, taking them as essential parameters of the compliance of a proficiency test provider with the general requirements set by the Guides. This intercomparison had special characteristics coming from the participants and the primary objective of the scheme. It is remarkable the important degree of agreement of the organization with Guides ISO/IEC 43 and ILAC G13. (author)

  13. Firefighting and Emergency Response Study of Advanced Composites Aircraft. Objective 3: Penetrating and Overhauling Wreckage

    Science.gov (United States)

    2011-10-01

    ompliance with the 150/ IEC 17025 ;md is a.ccredited by tm: Ame:ricw Association for Laboratory Accreditation(A2LA~ certificatt:s +1740.01 and +1740.02...ith the ISO / IEC 1 7025 and is accredited by t he American Association for L abo:ratol)’ Accreditation (A2LA), certificates ++741)_01 and ++741) _1...Test Labs - Charleston maintains a quality system incompliance with t~ 150/ IEC 17025 and is acrredited by the A~rican AssociationforL

  14. Study of uranium - 20 Wt per cent plutonium-niobium alloys (1963)

    International Nuclear Information System (INIS)

    Abgrall, J.; Barthelemy, P.; Boucher, R.

    1963-01-01

    U-Pu-Nb alloys containing 20 wt per cent Pu and 10 - 20 - 30 - 40 - 50 or 60 wt per cent Nb have been studied principally to determine the feasibility of their use as fuel element. The fabrication, casting and homogenisation presented certain difficulties due specially to niobium. The transformation temperatures, thermal expansion coefficients and nature of phases have been determined by thermal analysis, dilatometry, micrography and X Rays diffraction. For similar compositions, U-Pu-Mo and U-Pu-Nb alloys have many common points concerning the presence of zeta phase (up to 40 wt per cent Nb), the coefficients of expansion, the good behaviour during thermal cycling and the good resistance to air oxidation in spite of zeta phase. In consequence, irradiation tests in EL 3 reactor (Saclay) will be carried out in the near future. (authors) [fr

  15. Hardness and microstructural characteristics of rapidly solidified Al-8-16 wt.%Si alloys

    International Nuclear Information System (INIS)

    Uzun, O.; Karaaslan, T.; Gogebakan, M.; Keskin, M.

    2004-01-01

    Al-Si alloys with nominal composition of Al-8 wt.%Si, Al-12 wt.%Si, and Al-16 wt.%Si were rapidly solidified by using melt-spinning technique to examine the influence of the cooling rate/conditions on microstructure and mechanical properties. The microstructures of the rapidly solidified ribbons and ingot samples were investigated by the optical microscopy, electron microscopy and X-ray diffraction (XRD) techniques. The results showed that the structures of all melt-spun ribbons were completely composed of finely dispersed α-Al and eutectic Si phase, and primary silicon was not observed. The XRD analysis indicated that the solubility of Si in the α-Al matrix was greatly increased with rapid solidification. Additionally, mechanical properties of both conventionally cast (ingot) and melt-spun ribbons were examined by using Vickers indenter for one applied load (0.098 N). The hardness values of the melt-spun ribbons were about three times higher than those of ingot counterparts. The high hardness of the rapidly solidified state can be attributed to the supersaturated solid solutions. Besides, hardness values with different applied loads were measured for melt-spun ribbons. The results indicated that Vickers hardness values (H v ) of the ribbons depended on the applied load. Applying the concept of Hays-Kendall, the load independent hardness values were calculated as 694.0, 982.8 and 1186.8 MN/m 2 for Al-8 wt.%Si, Al-12 wt.%Si and Al-16 wt.%Si, respectively

  16. Microstructural evolution of a uranium-10 wt.% molybdenum alloy for nuclear reactor fuels

    International Nuclear Information System (INIS)

    Clarke, A.J.; Clarke, K.D.; McCabe, R.J.; Necker, C.T.; Papin, P.A.; Field, R.D.; Kelly, A.M.; Tucker, T.J.; Forsyth, R.T.; Dickerson, P.O.; Foley, J.C.; Swenson, H.; Aikin, R.M.; Dombrowski, D.E.

    2015-01-01

    Low-enriched uranium-10 wt.% molybdenum (LEU-10wt.%Mo) is of interest for the fabrication of monolithic fuels to replace highly-enriched uranium (HEU) dispersion fuels in high performance research and test reactors around the world. In this work, depleted uranium-10 wt.%Mo (DU-10wt.%Mo) is used to simulate the solidification and microstructural evolution of LEU-10wt.%Mo. Electron backscatter diffraction (EBSD) and complementary electron probe microanalysis (EPMA) reveal significant microsegregation present in the metastable γ-phase after solidification. Homogenization is performed at 800 and 1000 °C for times ranging from 1 to 32 h to explore the time–temperature combinations that will reduce the extent of microsegregation, as regions of higher and lower Mo content may influence local mechanical properties and provide preferred regions for γ-phase decomposition. We show for the first time that EBSD can be used to qualitatively assess microstructural evolution in DU-10wt.%Mo after homogenization treatments. Complementary EPMA is used to quantitatively confirm this finding. Homogenization at 1000 °C for 2–4 h may the regions that contain 8 wt.% Mo or lower, whereas homogenization at 1000 °C for longer than 8 h effectively saturates Mo chemical homogeneity, but results in substantial grain growth. The appropriate homogenization time will depend upon additional microstructural considerations, such as grain growth and intended subsequent processing. Higher carbon LEU-10wt.%Mo generally contains more inclusions within the grains and at grain boundaries after solidification. The effect of these inclusions on microstructural evolution (e.g. grain growth) during homogenization and as potential γ-phase decomposition nucleation sites is unclear, but likely requires additional study.

  17. Microstructural evolution of a uranium-10 wt.% molybdenum alloy for nuclear reactor fuels

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, A.J., E-mail: aclarke@lanl.gov; Clarke, K.D.; McCabe, R.J.; Necker, C.T.; Papin, P.A.; Field, R.D.; Kelly, A.M.; Tucker, T.J.; Forsyth, R.T.; Dickerson, P.O.; Foley, J.C.; Swenson, H.; Aikin, R.M.; Dombrowski, D.E.

    2015-10-15

    Low-enriched uranium-10 wt.% molybdenum (LEU-10wt.%Mo) is of interest for the fabrication of monolithic fuels to replace highly-enriched uranium (HEU) dispersion fuels in high performance research and test reactors around the world. In this work, depleted uranium-10 wt.%Mo (DU-10wt.%Mo) is used to simulate the solidification and microstructural evolution of LEU-10wt.%Mo. Electron backscatter diffraction (EBSD) and complementary electron probe microanalysis (EPMA) reveal significant microsegregation present in the metastable γ-phase after solidification. Homogenization is performed at 800 and 1000 °C for times ranging from 1 to 32 h to explore the time–temperature combinations that will reduce the extent of microsegregation, as regions of higher and lower Mo content may influence local mechanical properties and provide preferred regions for γ-phase decomposition. We show for the first time that EBSD can be used to qualitatively assess microstructural evolution in DU-10wt.%Mo after homogenization treatments. Complementary EPMA is used to quantitatively confirm this finding. Homogenization at 1000 °C for 2–4 h may the regions that contain 8 wt.% Mo or lower, whereas homogenization at 1000 °C for longer than 8 h effectively saturates Mo chemical homogeneity, but results in substantial grain growth. The appropriate homogenization time will depend upon additional microstructural considerations, such as grain growth and intended subsequent processing. Higher carbon LEU-10wt.%Mo generally contains more inclusions within the grains and at grain boundaries after solidification. The effect of these inclusions on microstructural evolution (e.g. grain growth) during homogenization and as potential γ-phase decomposition nucleation sites is unclear, but likely requires additional study.

  18. Information and communication technologies for operating of smart distribution grids based on the German standardization roadmap; Informations- und Kommunikationstechnologien zur Betriebsfuehrung smarter Verteilungsnetze auf Basis der Deutschen Normungsroadmap

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, Christoph [IT4Power, Zug (Switzerland); Buchholz, Bernd Michael [NTB Technoservice, Pyrbaum (Germany); Hampel, Herman [iAD GmbH, Grosshabersdorf (Germany); Naumann, A. [Magdeburg Univ. (Germany)

    2012-07-01

    The current challenges of the distribution networks are caused by a growing volume of distributed energy in-feed and new types of load. They require the introduction of information and communication technologies (ICT) down to the low voltage level. Innovative monitoring and control tasks are developed in the framework of the European lighthouse project ''Web2Energy'' (W2E) and performed in the practice of the 20/0.4 kV network of the HSE AG in Darmstadt. The overview of the realized functions is given and the related information exchange between the control centre and the distributed plants is considered. The project applies the standards IEC 61850 for data communication and IEC 61968/70 for the data management (CIM - Common Information Model) in the control center (CC). The client - server architecture of the developed communication system is considered in detail. The project related W2E CC serves the aspects of smart distribution also in the context with market activities. Data acquisition and control of the 20/0.4 kV terminals and the various power plants are executed by a mini remote terminal unit. The W2E RTU offers a 100 MBd Ethernet interface providing the IEC 61850 protocol for the access to the communication system. The required application specific extensions of the standards are discussed and the first experiences for application in the practice are demonstrated. (orig.)

  19. General criteria for validation of dosimetry methods in the context of a quality system ISO / IEC 17025; Criterios generales sobre validacion de metodos de dosimetria en el marco de un sistema de calidad ISO/IEC 17025

    Energy Technology Data Exchange (ETDEWEB)

    Martin Garcia, R.; Navarro Bravo, T.

    2011-07-01

    The accreditation of a testing laboratory in accordance with ISO / IEC 17025 recognizes the technical competence of a laboratory to perform certain tests. One of the requirements of that rule states that laboratories must demonstrate that the methods used are valid and appropriate for the intended use and customer needs. This demonstration is accomplished through the process of validation of methods, defined in the rule it self as {sup c}onfirmation by examination and provision of objective evidence that the requirements for a particular purpose{sup .} The process of validating a test method should be well planned and documented, including the requirements under the applicable rules and criteria established by the laboratory to comply with these requirements.

  20. The developments of international hydrogen and fuel cell technology standards and the response strategies in Taiwan

    International Nuclear Information System (INIS)

    Tso, C.

    2009-01-01

    The application of hydrogen and fuel cells has expanded as the technology in international markets has improved. Leading countries have focused on establishing hydrogen and fuel cell technology standards. Both the International Organization for Standardization (ISO) and the International Electrotechnical Commission (IEC) continuously release new hydrogen and fuel cell related standards. Although the government of Taiwan is promoting the development of a hydrogen and fuel cell industry, it may delay the commercialized schedule if there are no hydrogen and fuel cell related standards and regulations in place. Standards and regulations must be established as quickly as possible in order to accelerate the progress of the hydrogen and fuel cell industry. This presentation reviewed the international progress in hydrogen and fuel cell development and explained Taiwan's response strategies regarding the adoption of hydrogen and fuel cell products in niche Taiwanese markets

  1. Vehicle to Grid Communication Standards Development, Testing and Validation - Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Gowri, Krishnan; Pratt, Richard M.; Tuffner, Francis K.; Kintner-Meyer, Michael CW

    2011-09-01

    In the US, more than 10,000 electric vehicles (EV) have been delivered to consumers during the first three quarters of 2011. A large majority of these vehicles are battery electric, often requiring 220 volt charging. Though the vehicle manufacturers and charging station manufacturers have provided consumers options for charging preferences, there are no existing communications between consumers and the utilities to manage the charging demand. There is also wide variation between manufacturers in their approach to support vehicle charging. There are in-vehicle networks, charging station networks, utility networks each using either cellular, Wi-Fi, ZigBee or other proprietary communication technology with no standards currently available for interoperability. The current situation of ad-hoc solutions is a major barrier to the wide adoption of electric vehicles. SAE, the International Standards Organization/International Electrotechnical Commission (ISO/IEC), ANSI, National Institute of Standards and Technology (NIST) and several industrial organizations are working towards the development of interoperability standards. PNNL has participated in the development and testing of these standards in an effort to accelerate the adoption and development of communication modules.

  2. White Matter Fiber-based Analysis of T1w/T2w Ratio Map.

    Science.gov (United States)

    Chen, Haiwei; Budin, Francois; Noel, Jean; Prieto, Juan Carlos; Gilmore, John; Rasmussen, Jerod; Wadhwa, Pathik D; Entringer, Sonja; Buss, Claudia; Styner, Martin

    2017-02-01

    To develop, test, evaluate and apply a novel tool for the white matter fiber-based analysis of T1w/T2w ratio maps quantifying myelin content. The cerebral white matter in the human brain develops from a mostly non-myelinated state to a nearly fully mature white matter myelination within the first few years of life. High resolution T1w/T2w ratio maps are believed to be effective in quantitatively estimating myelin content on a voxel-wise basis. We propose the use of a fiber-tract-based analysis of such T1w/T2w ratio data, as it allows us to separate fiber bundles that a common regional analysis imprecisely groups together, and to associate effects to specific tracts rather than large, broad regions. We developed an intuitive, open source tool to facilitate such fiber-based studies of T1w/T2w ratio maps. Via its Graphical User Interface (GUI) the tool is accessible to non-technical users. The framework uses calibrated T1w/T2w ratio maps and a prior fiber atlas as an input to generate profiles of T1w/T2w values. The resulting fiber profiles are used in a statistical analysis that performs along-tract functional statistical analysis. We applied this approach to a preliminary study of early brain development in neonates. We developed an open-source tool for the fiber based analysis of T1w/T2w ratio maps and tested it in a study of brain development.

  3. White matter fiber-based analysis of T1w/T2w ratio map

    Science.gov (United States)

    Chen, Haiwei; Budin, Francois; Noel, Jean; Prieto, Juan Carlos; Gilmore, John; Rasmussen, Jerod; Wadhwa, Pathik D.; Entringer, Sonja; Buss, Claudia; Styner, Martin

    2017-02-01

    Purpose: To develop, test, evaluate and apply a novel tool for the white matter fiber-based analysis of T1w/T2w ratio maps quantifying myelin content. Background: The cerebral white matter in the human brain develops from a mostly non-myelinated state to a nearly fully mature white matter myelination within the first few years of life. High resolution T1w/T2w ratio maps are believed to be effective in quantitatively estimating myelin content on a voxel-wise basis. We propose the use of a fiber-tract-based analysis of such T1w/T2w ratio data, as it allows us to separate fiber bundles that a common regional analysis imprecisely groups together, and to associate effects to specific tracts rather than large, broad regions. Methods: We developed an intuitive, open source tool to facilitate such fiber-based studies of T1w/T2w ratio maps. Via its Graphical User Interface (GUI) the tool is accessible to non-technical users. The framework uses calibrated T1w/T2w ratio maps and a prior fiber atlas as an input to generate profiles of T1w/T2w values. The resulting fiber profiles are used in a statistical analysis that performs along-tract functional statistical analysis. We applied this approach to a preliminary study of early brain development in neonates. Results: We developed an open-source tool for the fiber based analysis of T1w/T2w ratio maps and tested it in a study of brain development.

  4. Evidence that WT1 mutations in Denys-Drash syndrome patients may act in a dominant-negative fashion

    NARCIS (Netherlands)

    Little, M. H.; Williamson, K. A.; Mannens, M.; Kelsey, A.; Gosden, C.; Hastie, N. D.; van Heyningen, V.

    1993-01-01

    The triad of nephropathy, partial gonadal dysgenesis and Wilms' tumour (WT) is known as Denys-Drash syndrome (DDS). The WT predisposition gene WT1, which plays a vital role in both genital and renal development, is known to be mutated in DDS patients. The WT1 mutations in these patients are

  5. Faults detection approach using PCA and SOM algorithm in PMSG-WT system

    Directory of Open Access Journals (Sweden)

    Mohamed Lamine FADDA

    2016-07-01

    Full Text Available In this paper, a new approach for faults detection in observable data system wind turbine - permanent magnet synchronous generator (WT-PMSG, the studying objective, illustrate the combination (SOM-PCA to build Multi-local-PCA models faults detection in system (WT-PMSG, the performance of the method suggested to faults detection in system data, finding good results in simulation experiment.

  6. Study on the Mechanical Properties and Corrosion Behaviors of Fe-(20, 45) wt%Gd Intermetallics

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Bo Kyeong; Baik, Youl; Choi, Yong [Dankook University, Chungnam (Korea, Republic of); Moon, Byung Moon [Korea Institute of Industrial Technology, Incheon (Korea, Republic of)

    2017-02-15

    Fe-(20, 45 wt%) Gd intermetallics were vacuum arc melted as the mother alloy of a neutron shielding and absorbing material. The structure of the cast Fe-20 wt%Gd intermetallics had primary dendrites with a short width of about 2 μm, which became coarse with increasing Gd content. The final compositions of the Fe-20 wt%Gd and Fe-45 wt%Gd intermetallics determined by Rietveld refinement were mainly Fe{sub 3}Gd with 26.6 at%Fe{sub 2}Gd, and Fe{sub 3}Gd with various intermetallics like 13.9 at%Fe{sub 2}Gd, 7.3 at%Fe{sub 9}Gd and 3.9 at%Fe{sub 17}Gd{sub 2}, respectively. The micro-hardnesses, yield strength, ultimate compressive strength and elongation of the Fe-20 wt%Gd intermetallics were 629±12 Hv, 753 MPa, 785 MPa and 4%, respectively, and those of the Fe-45 wt%Gd intermetallics were 741±13 Hv, 772 MPa, 823 MPa and 3%. Passivity was not present in artificial sea water at room temperature. The corrosion potentials and the corrosion rates of the Fe-20 wt%Gd and Fe-45 wt%Gd intermetallics were –624 mV{sub SHE}, 2.771 mA/cm{sup 2} , and –804 mV{sub SHE}, 3.397 mA/cm{sup 2} , respectively. The corroded surface of the Fe-Gd intermetallics contained corrosion products like gadolinium with iron, which detached to leave a trail of pits.

  7. Fabrication and properties of strip casting 4.5 wt% Si steel thin sheet

    Energy Technology Data Exchange (ETDEWEB)

    Zu, Guoqing, E-mail: gz854@uowmail.edu.au [State Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110819 (China); School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, NSW 2522 (Australia); Zhang, Xiaoming [State Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110819 (China); Zhao, Jingwei [School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, NSW 2522 (Australia); Wang, Yuqian [State Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110819 (China); Yan, Yi [School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, NSW 2522 (Australia); Li, Chengang; Cao, Guangming [State Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110819 (China); Jiang, Zhengyi [School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, NSW 2522 (Australia)

    2017-02-15

    Three 4.5 wt% Si steel thin sheets with different thicknesses were efficiently fabricated by twin-roll strip casting, warm rolling and cold rolling followed by final annealing. A comprehensive investigation from the workability of the as-cast strip to the magnetic property of the produces was performed to illustrate the superiority of the new materials. The results show that the as-cast strip, which has a much lower Vickers hardness than that of the 6.5 wt% Si steel, is suitable for rolling processing. The X-ray diffraction (XRD) and transmission electron microscopy (TEM) studies confirm that no ordering phase exists in the as-cast strip. The cold-rolled thin sheets exhibit good surface quality without edge cracks. Furthermore, all the three 4.5 wt% Si steel thin sheets possess relative strong <100>//ND texture and present high magnetic inductions and low iron losses after finial annealing. - Highlights: • 4.5 wt% Si as-cast sheet with excellent workability was produced by strip casting. • Three 4.5 wt% Si thin sheets were effectively fabricated by warm and cold rolling. • The microstructure and macro-texture of the thin sheets were elucidated. • High magnetic inductions and low iron losses were achieved simultaneously.

  8. Accrediting of the OKTA Laboratory - Harmonizing with the European standards

    International Nuclear Information System (INIS)

    Denkovski, Gligor

    2004-01-01

    In the energetics of Republic of Macedonia, after 13 years of independence of the country, there is still chaos in applying of many standards that are not used any more, even in the countries from which they are taken over. Step forward is the applying of the new standards in the oil industry. Control of applying of these standards is still open question. Factory laboratories regardless their equipping are not formally authorized to perform analysis for purposes other than those for their own needs. With establishing of Accrediting Institute of Republic of Macedonia (IARM), and adopting of corresponding regulations, there are conditions for accrediting of laboratories in order of giving services to the State and other users. Subject of this work is accrediting of the laboratory of OKTA - Crude Oil Refinery, Skopje, according the international standard ISO / IEC 17025. Finally this will be beginning of the control of import of crude oil products with suspicious origin and quality, that have been on the Macedonian market for years. (Author)

  9. SUSY WT identity in a lattice formulation of 2D N=(2,2) SYM

    International Nuclear Information System (INIS)

    Kadoh, Daisuke; Suzuki, Hiroshi

    2010-01-01

    We address some issues relating to a supersymmetric (SUSY) Ward-Takahashi (WT) identity in Sugino's lattice formulation of two-dimensional (2D) N=(2,2)SU(k) supersymmetric Yang-Mills theory (SYM). A perturbative argument shows that the SUSY WT identity in the continuum theory is reproduced in the continuum limit without any operator renormalization/mixing and tuning of lattice parameters. As application of the lattice SUSY WT identity, we show that a prescription for the Hamiltonian density in this lattice formulation, proposed by Kanamori, Sugino and Suzuki, is justified also from a perspective of an operator algebra among correctly-normalized supercurrents. We explicitly confirm the SUSY WT identity in the continuum limit to the first nontrivial order in a semi-perturbative expansion.

  10. Optimization of Surrounding Reflector Material for Hyb-WT

    International Nuclear Information System (INIS)

    Tariq Siddique, M.; Hong, Song Hee; Kim, Myung Hyun

    2013-01-01

    The choice of reflector material is crucial for fusion and hybrid reactors as it was for the fission reactors. Multiple reflector materials were studied for pure fusion blanket design. The purpose of reflector in fusion blanket is to enhance the tritium breeding ratio (TBR). In fusion fission hybrid blanket the roll of reflector is slightly changed as it include the fission core and the performance of fission core also needs to be optimized and evaluated with the choice of reflector material, along with the enhancement of TBR. The performance parameters of Hyb-WT are significantly influenced by the choice of reflector material. TiC is best for TRU transmutation, TBR and reduced the neutron wall loading and graphite is best for FP transmutation. Strategy of multi reflector materials gives the best TRU and FP transmutation performance and also enhanced TBR with reduced neutron wall loading and it is a better choice for Hyb-WT reflector. The neutron flux is primarily dominated by the fission neutrons

  11. Air pollution control systems in WtE units: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Vehlow, J., E-mail: juergen.vehlow@partner.kit.edu

    2015-03-15

    Highlights: • The paper describes in brief terms the development of gas cleaning in waste incineration. • The main technologies for pollutant removal are described including their basic mechanisms. • Their respective efficiencies and their application are discussed. • A cautious outlook regarding future developments is made. - Abstract: All WtE (waste-to-energy) plants, based on combustion or other thermal processes, need an efficient gas cleaning for compliance with legislative air emission standards. The development of gas cleaning technologies started along with environment protection regulations in the late 1960s. Modern APC (air pollution control) systems comprise multiple stages for the removal of fly ashes, inorganic and organic gases, heavy metals, and dioxins from the flue gas. The main technologies and devices used for abatement of the various pollutants are described and their basic principles, their peculiarities, and their application are discussed. Few systems for cleaning of synthesis gas from waste gasification plants are included. Examples of APC designs in full scale plants are shown and cautious prospects for the future development of APC systems are made.

  12. Air pollution control systems in WtE units: An overview

    International Nuclear Information System (INIS)

    Vehlow, J.

    2015-01-01

    Highlights: • The paper describes in brief terms the development of gas cleaning in waste incineration. • The main technologies for pollutant removal are described including their basic mechanisms. • Their respective efficiencies and their application are discussed. • A cautious outlook regarding future developments is made. - Abstract: All WtE (waste-to-energy) plants, based on combustion or other thermal processes, need an efficient gas cleaning for compliance with legislative air emission standards. The development of gas cleaning technologies started along with environment protection regulations in the late 1960s. Modern APC (air pollution control) systems comprise multiple stages for the removal of fly ashes, inorganic and organic gases, heavy metals, and dioxins from the flue gas. The main technologies and devices used for abatement of the various pollutants are described and their basic principles, their peculiarities, and their application are discussed. Few systems for cleaning of synthesis gas from waste gasification plants are included. Examples of APC designs in full scale plants are shown and cautious prospects for the future development of APC systems are made

  13. Room Temperature Mechanical Properties of A356 Alloy with Ni Additions from 0.5 Wt to 2 Wt %

    Directory of Open Access Journals (Sweden)

    Lucia Lattanzi

    2018-03-01

    Full Text Available In recent years, the influence of Ni on high-temperature mechanical properties of casting Al alloys has been extensively examined in the literature. In the present study, room temperature mechanical properties of an A356 alloy with Ni additions from 0.5 to 2 wt % were investigated. The role of Ni-based compounds and eutectic Si particles in reinforcing the Al matrix was studied with image analysis and was then related to tensile properties and microhardness. In the as-cast condition, the formation of the 3D network is not sufficient to determine an increase of mechanical properties of the alloys since fracture propagates by cleavage through eutectic Si particles and Ni aluminides or by the debonding of brittle phases from the aluminum matrix. After T6 heat treatment the increasing amount of Ni aluminides, due to further addition of Ni to the alloy, together with their brittle behavior, leads to a decrease of yield strength, ultimate tensile strength, and Vickers microhardness. Despite the fact that Ni addition up to 2 wt % hinders spheroidization of eutectic Si particles during T6 heat treatment, it also promotes the formation of a higher number of brittle Ni-based compounds that easily promote fracture propagation.

  14. Differential evolution of a CXCR4-using HIV-1 strain in CCR5wt/wt and CCR5∆32/∆32 hosts revealed by longitudinal deep sequencing and phylogenetic reconstruction.

    Science.gov (United States)

    Le, Anh Q; Taylor, Jeremy; Dong, Winnie; McCloskey, Rosemary; Woods, Conan; Danroth, Ryan; Hayashi, Kanna; Milloy, M-J; Poon, Art F Y; Brumme, Zabrina L

    2015-12-03

    Rare individuals homozygous for a naturally-occurring 32 base pair deletion in the CCR5 gene (CCR5∆32/∆32) are resistant to infection by CCR5-using ("R5") HIV-1 strains but remain susceptible to less common CXCR4-using ("X4") strains. The evolutionary dynamics of X4 infections however, remain incompletely understood. We identified two individuals, one CCR5wt/wt and one CCR5∆32/∆32, within the Vancouver Injection Drug Users Study who were infected with a genetically similar X4 HIV-1 strain. While early-stage plasma viral loads were comparable in the two individuals (~4.5-5 log10 HIV-1 RNA copies/ml), CD4 counts in the CCR5wt/wt individual reached a nadir of 250 cells/mm(3) in the CCR5∆32/∆32 individual. Ancestral phylogenetic reconstructions using longitudinal envelope-V3 deep sequences suggested that both individuals were infected by a single transmitted/founder (T/F) X4 virus that differed at only one V3 site (codon 24). While substantial within-host HIV-1 V3 diversification was observed in plasma and PBMC in both individuals, the CCR5wt/wt individual's HIV-1 population gradually reverted from 100% X4 to ~60% R5 over ~4 years whereas the CCR5∆32/∆32 individual's remained consistently X4. Our observations illuminate early dynamics of X4 HIV-1 infections and underscore the influence of CCR5 genotype on HIV-1 V3 evolution.

  15. Corrosion behavior of Mg–5Al based magnesium alloy with 1 wt.% Sn, Mn and Zn additions in 3.5 wt.% NaCl solution

    Directory of Open Access Journals (Sweden)

    Nguyen Dang Nam

    2014-06-01

    Full Text Available The corrosion properties of four Mg–5Al alloys with M-alloying elements (tin, manganese and zinc in a 3.5 wt.% NaCl solution were examined using electrochemical tests and surface analyses. The electrochemical results indicated that the addition of 1 wt.% M metal decreased the corrosion rate and hydrogen evolution rate of the Mg–5Al specimens. Moreover, the addition of 1Zn resulted in having the best corrosion resistance due to the interaction of Zn oxide with Mg and Al oxides which acted as a corrosion barrier.

  16. Demonstration of the Gore Module for Passive Ground Water Sampling

    Science.gov (United States)

    2014-06-01

    Organization for Standardization ( ISO )/International Electrotechnical Commission ( IEC ) 17025 , DoD ELAP, and NELAC quality standards for USEPA Method...mass spectrometry GCB Geochemical Sciences Branch GT glacial till HSE Health and Safety Executive IEC International Electrotechnical Commission...IRP Installation Restoration Program ACRONYMS AND ABBREVIATIONS (continued) x ISO International Organization for Standardization ITRC

  17. 75 FR 70911 - Third Party Testing for Certain Children's Products; Children's Sleepwear, Sizes 0 Through 6X and...

    Science.gov (United States)

    2010-11-19

    ... ISO/IEC 17025:2005, General Requirements for the Competence of Testing and Calibration Laboratories... requirements of the ISO[sol]IEC 17025:2005 laboratory accreditation standard is provided in the CPSC staff...]IEC 17025 accredited by an ILAC-MRA signatory and the scope of the accreditation included the...

  18. Harnessing ISO/IEC 12207 to Examine the Extent of SPI Activity in an Organisation

    Science.gov (United States)

    Clarke, Paul; O'Connor, Rory

    The quality of the software development process directly affects the quality of the software product. To be successful, software development organisations must respond to changes in technology and business circumstances, and therefore software process improvement (SPI) is required. SPI activity relates to any modification that is performed to the software process in order to improve an aspect of the process. Although multiple process assessments could be employed to examine SPI activity, they present an inefficient tool for such an examination. This paper presents an overview of a new survey-based resource that utilises the process reference model in ISO/IEC 12207 in order to expressly and directly determine the level of SPI activity in a software development organisation. This survey instrument can be used by practitioners, auditors and researchers who are interested in determining the extent of SPI activity in an organisation.

  19. IEC Information Bulletin, No. 44, Second Quarter 2013

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-09-15

    The latest publication in the IAEA Emergency Preparedness and Response (EPR)-series, Actions to Protect the Public in an Emergency due to Severe Conditions at a Light Water Reactor (EPR-NPP PUBLIC PROTECTIVE ACTIONS, 2013), was issued in May 2013. It is intended for those responsible for making and for acting on decisions in the event of an emergency involving actual or projected severe damage to the fuel in the reactor core or in the spent fuel pool of a light water reactor, to provide an understanding of the actions necessary to protect the public. It provides a basis for developing the tools and criteria at the preparedness stage that would be needed to take appropriate protective actions and other actions in response to an emergency. It provides guidance on: - Taking actions to protect the public based on conditions at the nuclear power plant using an emergency classification system; - Assessing environmental monitoring measurements taken after a release of radioactive material to determine if protective actions are needed; and - How to place the radiological health hazard in perspective for the public and answer key questions, such as ''Am I safe?'' and ''What do I need to do to protect myself and family?'' The publication is currently only available in English, but will soon be available in Spanish and Russian. The associated training materials will be available from the IAEA's and the Incident and Emergency Centre's websites later this year, and are also planned to be translated into other official UN languages. In addition, the IEC offers workshops on this publication at the national, regional and inter regional levels when requested by a Member State.

  20. IEC Information Bulletin, No. 44, Second Quarter 2013

    International Nuclear Information System (INIS)

    2013-09-01

    The latest publication in the IAEA Emergency Preparedness and Response (EPR)-series, Actions to Protect the Public in an Emergency due to Severe Conditions at a Light Water Reactor (EPR-NPP PUBLIC PROTECTIVE ACTIONS, 2013), was issued in May 2013. It is intended for those responsible for making and for acting on decisions in the event of an emergency involving actual or projected severe damage to the fuel in the reactor core or in the spent fuel pool of a light water reactor, to provide an understanding of the actions necessary to protect the public. It provides a basis for developing the tools and criteria at the preparedness stage that would be needed to take appropriate protective actions and other actions in response to an emergency. It provides guidance on: - Taking actions to protect the public based on conditions at the nuclear power plant using an emergency classification system; - Assessing environmental monitoring measurements taken after a release of radioactive material to determine if protective actions are needed; and - How to place the radiological health hazard in perspective for the public and answer key questions, such as ''Am I safe?'' and ''What do I need to do to protect myself and family?'' The publication is currently only available in English, but will soon be available in Spanish and Russian. The associated training materials will be available from the IAEA's and the Incident and Emergency Centre's websites later this year, and are also planned to be translated into other official UN languages. In addition, the IEC offers workshops on this publication at the national, regional and inter regional levels when requested by a Member State

  1. Community-based IEC campaign. TFR has dropped to 2.15 in Binh Thanh District, Ho Chi Minh City.

    Science.gov (United States)

    Nguyen Ngoc Lich

    1995-01-01

    Binh Thanh District of Ho Chin Minh City in 1989 had a crude birth rate (CBR) of 20.3 per 1000 population and an average of 5.5 persons per household. The rate of total fertility (TFR) in the district was one of the highest among the city's 18 districts in 1990. Concerned about these demographics, the Binh Thanh District Committee for Population and Family Planning reviewed the family planning program with the goal of developing a special information, education, and communication (IEC) campaign. The following incentive scheme for sterilization was developed: each poor entrepreneur in need of seed money for new business ventures who allows himself to be sterilized receives dong 120,000 (US$11) from the National Committee for Population and Family Planning and dong 220,000 from the District Committee for Population and Family Planning to buy medicine and supplementary food. An IEC room was established in each commune health center to disseminate the relevant information. The results of the campaign have been positive, with 910 people requesting sterilization in 1994, 34% of whom were male. Over the period January-April 1995, the proportion of male sterilization increased dramatically, such that men accounted for 68% of the 153 people who underwent sterilization. The district now ranks the lowest among the 18 districts with regard to the percentage of couples with three children, the CBR is 15.3/1000, TFR is 2.15, the contraceptive prevalence rate is 68%, and sterilization is the fourth most popular method of contraception (13%) behind the IUD (37%), condom (30%), and oral pill (18.5%).

  2. Industrial radioprotection - interpretations of the standard CNEN-NE-3.01

    International Nuclear Information System (INIS)

    Dagnino, R.; Zaniolo, C.

    1989-01-01

    The safety standard established by Comissao Nacional de Energia Nuclear - Brazilian CNEN, to rule the activities related to radioprotection, embodies various professionals activities. In this article a specific analysis about the application of the standard to industry is presented. (author)

  3. Evaluation of the measurement uncertainty when measuring the resistance of solid isolating materials to tracking

    Science.gov (United States)

    Stare, E.; Beges, G.; Drnovsek, J.

    2006-07-01

    This paper presents the results of research into the measurement of the resistance of solid isolating materials to tracking. Two types of tracking were investigated: the proof tracking index (PTI) and the comparative tracking index (CTI). Evaluation of the measurement uncertainty in a case study was performed using a test method in accordance with the IEC 60112 standard. In the scope of the tests performed here, this particular test method was used to ensure the safety of electrical appliances. According to the EN ISO/IEC 17025 standard (EN ISO/IEC 17025), in the process of conformity assessment, the evaluation of the measurement uncertainty of the test method should be carried out. In the present article, possible influential parameters that are in accordance with the third and fourth editions of the standard IEC 60112 are discussed. The differences, ambiguities or lack of guidance referring to both editions of the standard are described in the article 'Ambiguities in technical standards—case study IEC 60112—measuring the resistance of solid isolating materials to tracking' (submitted for publication). Several hundred measurements were taken in the present experiments in order to form the basis for the results and conclusions presented. A specific problem of the test (according to the IEC 60112 standard) is the great variety of influential physical parameters (mechanical, electrical, chemical, etc) that can affect the results. At the end of the present article therefore, there is a histogram containing information on the contributions to the measurement uncertainty.

  4. CIEMAT EXTERNAL DOSIMETRY SERVICE: ISO/IEC 17025 ACCREDITATION AND 3 Y OF OPERATIONAL EXPERIENCE AS AN ACCREDITED LABORATORY.

    Science.gov (United States)

    Romero, A M; Rodríguez, R; López, J L; Martín, R; Benavente, J F

    2016-09-01

    In 2008, the CIEMAT Radiation Dosimetry Service decided to implement a quality management system, in accordance with established requirements, in order to achieve ISO/IEC 17025 accreditation. Although the Service comprises the approved individual monitoring services of both external and internal radiation, this paper is specific to the actions taken by the External Dosimetry Service, including personal and environmental dosimetry laboratories, to gain accreditation and the reflections of 3 y of operational experience as an accredited laboratory. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Efficiency increase of a high-efficient IEC 3 kW permanent-magnet-motor - Implementation in a pump system; Effizienzsteigerung eines hocheffizienten IEC 3 kW Permanent-Magnet-Motors inklusiv energetische Messung als Pumpenanwendung - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Lindegger, M. [Circle Motor AG, Guemligen (Switzerland); Biner, H.-P.; Evequoz, B. [University of Applied Sciences, Western Switzerland, Delemont (Switzerland); Salathe, D. [Fachhochschule Luzern, Technik und Architektur, Horw (Switzerland)

    2009-11-15

    The IEC norm 60034-30 defines new international standards for efficiency of electric motors. IE1 is standard efficiency, IE2 is high efficiency, and IE3/IE4 are the premium class. Circle Motor AG assumes that the premium class efficiency factor for motors with power less than 22 kW is easier to achieve with Permanent-Magnet-Motors enhanced by electric inverters than with asynchronous motors. The goal of this work is to achieve an overall 'efficiency factor' of 90% through a high-efficiency 3 kW-rated input Permanent-Magnet-Motor enhanced with an electric inverter, and then to perform measurements on the pump drive. The 'efficiency factor' measurement results showed worse performance than expected for both the inverter and the motor. One reason is due to high iron losses in the motor that are produced by high frequency currents of inverter. Another reason is the relatively high ohmic resistance of the copper motor winding caused by the chosen coil production method. By filtering high frequency currents at the rated power, the motor efficiency factor reaches up to 89.5%, which complies with premium class IE3. In generator mode the efficiency reaches 92.8%. We note that the positive result of this work is that the inverter can be produced with very low standby power losses - in our current work with 160 mW. It is necessary to admit that every detail can be responsible for success or failure during research and development activities of premium class motors. The optimization activities mainly belong to the area of additional losses of electric machines. In this report we have encountered all research results on the theme of Additional Losses that resulted from the current research work. The concept of drive control from the previous research project has shown itself as efficiency aware. The total efficiency factor of 90% can be reached by a system coupling a drive controller with a synchronous motor and the 'know how' from this work. The

  6. Microstructures and tensile properties of Mg–4Al–4La–0.4Mn–xB (x = 0, 0.01, 0.02, 0.03) alloy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qiang [State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Graduate School, Chinese Academy of Sciences, Beijing 100049 (China); Zheng, Tian; Zhang, Deping; Liu, Xiaojuan [State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Fan, Jun [State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Graduate School, Chinese Academy of Sciences, Beijing 100049 (China); Qiu, Xin; Niu, Xiaodong [State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Meng, Jian, E-mail: jmeng@ciac.jl.cn [State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)

    2013-09-25

    Highlights: •The trace boron can refine the dendrite arm spacing of HPDC Mg–Al–La-based alloy. •The dispersion of Al11La3 particles becomes irregular after adding trace boron. •The eutectic volume fraction is reduced by adding 0.01–0.02 wt.% boron. •Mechanical properties could be further improved by 0.03 wt.% boron addition. -- Abstract: The influences of trace boron on microstructures and tensile properties of Mg–4Al–4La-based alloys prepared by cold-chamber high-pressure die-casting method were thoroughly investigated. The results indicated that adding trace boron to Mg–4Al–4La-based alloy can refine the dendrite arm spacing of primary α-Mg phases, which are mainly due to the little inoculating AlB{sub 2} particles. In addition, we found that adding 0.01–0.02 wt.% boron can drastically changes the eutectic morphology, with secondary particle dispersion becoming irregular and eutectic volume fraction being reduced. These phenomena can be attributed to the competitive nucleation between α-Mg and AlB{sub 2} particles for Al{sub 11}La{sub 3} phases, and to the fact that more Al and La atoms saturate into the α-Mg matrix. Considering the tensile properties, although adding 0.01–0.02 wt.% boron decreased the strength of Mg–4Al–4La-based alloy, adding 0.03 wt.% boron significantly improved the tensile properties due to dispersion strengthening and, to a certain extent, solid-solution strengthening.

  7. Porosity Effect on Thermal Properties of Al-12 wt % Si/Graphite Composites

    Directory of Open Access Journals (Sweden)

    José-Miguel Molina

    2017-02-01

    Full Text Available The effect of porosity on the thermal conductivity and the coefficient of thermal expansion of composites obtained by infiltration of Al-12 wt % Si alloy into graphite particulate preforms has been determined. Highly irregular graphite particles were used to fabricate the preforms. The thermal conductivity of these composites gradually increases with the applied infiltration pressure given the inherent reduction in porosity. A simple application of the Hasselman-Johnson model in a two-step procedure (that accounts for the presence of both graphite particles and voids randomly dispersed in a metallic matrix offers a good estimation of the experimental results. As concerns the coefficient of thermal expansion, the results show a slight increase with saturation being approximately in the range 14.6–15.2 × 10−6 K−1 for a saturation varying from 86% up to 100%. Results lie within the standard Hashin-Strikman bounds.

  8. Porosity Effect on Thermal Properties of Al-12 wt % Si/Graphite Composites.

    Science.gov (United States)

    Molina, José-Miguel; Rodríguez-Guerrero, Alejandro; Louis, Enrique; Rodríguez-Reinoso, Francisco; Narciso, Javier

    2017-02-14

    The effect of porosity on the thermal conductivity and the coefficient of thermal expansion of composites obtained by infiltration of Al-12 wt % Si alloy into graphite particulate preforms has been determined. Highly irregular graphite particles were used to fabricate the preforms. The thermal conductivity of these composites gradually increases with the applied infiltration pressure given the inherent reduction in porosity. A simple application of the Hasselman-Johnson model in a two-step procedure (that accounts for the presence of both graphite particles and voids randomly dispersed in a metallic matrix) offers a good estimation of the experimental results. As concerns the coefficient of thermal expansion, the results show a slight increase with saturation being approximately in the range 14.6-15.2 × 10 -6 K -1 for a saturation varying from 86% up to 100%. Results lie within the standard Hashin-Strikman bounds.

  9. Fabrication of U-10wt.%Zr Fuel slug for SFR by Injection Casting

    International Nuclear Information System (INIS)

    Kim, Jong Hwan; Song, Hoon; Kim, Hyung Tae; Ko, Young Mo; Kim, Ki Hwan; Lee, Chan B.

    2013-01-01

    The fabrication technology of metal fuel has been developed by various methods such as rolling, swaging, wire drawing, and co-extrusion, but each of these methods had process limitations requiring an additional subsequent process, and needing the fabrication equipment is complex, which is not favorable for remote use. A practical process of metallic fuel fabrication for an SFR needs to be cost efficient, suitable for remote operation, and capable of mass production while reducing the amount of radioactive waste. Injection casting was chosen as the most promising technique, in the early 1950s, and this technique has been applied to fuel slug fabrication for the Experimental Breeder Reactor-II (EBR-II) driver and the Fast Flux Test Facility (FFTF) fuel pins. Because of the simplistic nature of the process and equipment, compared to other processes examined, this process has been successfully used in a remote operation environment for fueling of the EBR-II reactor. In this study, vacuum injection casting suitable for remote operation has been developed to fabricate metallic fuel for an SFR. Vacuum injection casting technique was developed to fabricate metallic fuel for an SFR. The appearance of the fabricated U-10wt.%Zr fuel was generally sound and the internal integrity was found to be satisfactory through gamma-ray radiography. Minimum fuel losses after casting relative to the initial charge amount of U-10wt.%Zr fuel slugs met the proposed goal of less than 0.1% fuel losses during fabrication. Modifications of the current facility system and advanced casting techniques are underway to produce higher quality fuel slugs

  10. Fabrication of U-10wt.%Zr Fuel slug for SFR by Injection Casting

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Hwan; Song, Hoon; Kim, Hyung Tae; Ko, Young Mo; Kim, Ki Hwan; Lee, Chan B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The fabrication technology of metal fuel has been developed by various methods such as rolling, swaging, wire drawing, and co-extrusion, but each of these methods had process limitations requiring an additional subsequent process, and needing the fabrication equipment is complex, which is not favorable for remote use. A practical process of metallic fuel fabrication for an SFR needs to be cost efficient, suitable for remote operation, and capable of mass production while reducing the amount of radioactive waste. Injection casting was chosen as the most promising technique, in the early 1950s, and this technique has been applied to fuel slug fabrication for the Experimental Breeder Reactor-II (EBR-II) driver and the Fast Flux Test Facility (FFTF) fuel pins. Because of the simplistic nature of the process and equipment, compared to other processes examined, this process has been successfully used in a remote operation environment for fueling of the EBR-II reactor. In this study, vacuum injection casting suitable for remote operation has been developed to fabricate metallic fuel for an SFR. Vacuum injection casting technique was developed to fabricate metallic fuel for an SFR. The appearance of the fabricated U-10wt.%Zr fuel was generally sound and the internal integrity was found to be satisfactory through gamma-ray radiography. Minimum fuel losses after casting relative to the initial charge amount of U-10wt.%Zr fuel slugs met the proposed goal of less than 0.1% fuel losses during fabrication. Modifications of the current facility system and advanced casting techniques are underway to produce higher quality fuel slugs.

  11. Analysis of Power Transfer Efficiency of Standard Integrated Circuit Immunity Test Methods

    Directory of Open Access Journals (Sweden)

    Hai Au Huynh

    2015-01-01

    Full Text Available Direct power injection (DPI and bulk current injection (BCI methods are defined in IEC 62132-3 and IEC 62132-4 as the electromagnetic immunity test method of integrated circuits (IC. The forward power measured at the RF noise generator when the IC malfunctions is used as the measure of immunity level of the IC. However, the actual power that causes failure in ICs is different from forward power measured at the noise source. Power transfer efficiency is used as a measure of power loss of the noise injection path. In this paper, the power transfer efficiencies of DPI and BCI methods are derived and validated experimentally with immunity test setup of a clock divider IC. Power transfer efficiency varies significantly over the frequency range as a function of the test method used and the IC input impedance. For the frequency range of 15 kHz to 1 GHz, power transfer efficiency of the BCI test was constantly higher than that of the DPI test. In the DPI test, power transfer efficiency is particularly low in the lower test frequency range up to 10 MHz. When performing the IC immunity tests following the standards, these characteristics of the test methods need to be considered.

  12. Advancements in Wind Energy Metrology – UPWIND 1A2.3

    DEFF Research Database (Denmark)

    Angelou, Nikolas; Bingöl, Ferhat; Courtney, Michael

    of wind turbines. These measurements document the meandering wake pattern. The second part of the overview considers power performance measurements. A new investigation on the influence of wind shear points to a revision of the definition of a power curve. A new measurement method has been developed which...... has a good chance of being implemented in the present revision of the IEC performance standard. Also, a turbulence normalization method has been tested but not found efficient enough for inclusion in the IEC standard. In relation to the coming IEC standard on performance verification with the use...

  13. Study on Cyber Security and Threat Evaluation in SCADA Systems

    Science.gov (United States)

    2012-03-01

    125 4.3.2 ISO 27001 , 27002 ............................................................................................ 125 4.3.3...system environments. 4.3.2 ISO 27001 , 27002 The ISO 27001 and 27002 standards ensure proper security processes and technology are implemented in...asset owner, integrators, and vendors. Now it is an independent set of 3 standards which resemble the ISO /IEC 27001 and 27002 standards. ISO /IEC

  14. Spirulina platensis Improves Mitochondrial Function Impaired by Elevated Oxidative Stress in Adipose-Derived Mesenchymal Stromal Cells (ASCs) and Intestinal Epithelial Cells (IECs), and Enhances Insulin Sensitivity in Equine Metabolic Syndrome (EMS) Horses.

    Science.gov (United States)

    Nawrocka, Daria; Kornicka, Katarzyna; Śmieszek, Agnieszka; Marycz, Krzysztof

    2017-08-03

    Equine Metabolic Syndrome (EMS) is a steadily growing life-threatening endocrine disorder linked to insulin resistance, oxidative stress, and systemic inflammation. Inflammatory microenvironment of adipose tissue constitutes the direct tissue milieu for various cell populations, including adipose-derived mesenchymal stromal cells (ASCs), widely considered as a potential therapeutic cell source in the course of the treatment of metabolic disorders. Moreover, elevated oxidative stress induces inflammation in intestinal epithelial cells (IECs)-the first-line cells exposed to dietary compounds. In the conducted research, we showed that in vitro application of Spirulina platensis contributes to the restoration of ASCs' and IECs' morphology and function through the reduction of cellular oxidative stress and inflammation. Enhanced viability, suppressed senescence, and improved proliferation of ASCs and IECs isolated from metabolic syndrome-affected individuals were evident following exposition to Spirulina. A protective effect of the investigated extract against mitochondrial dysfunction and degeneration was also observed. Moreover, our data demonstrate that Spirulina extract effectively suppressed LPS-induced inflammatory responses in macrophages. In vivo studies showed that horses fed with a diet based on Spirulina platensis supplementation lost weight and their insulin sensitivity improved. Thus, our results indicate the engagement of Spirulina platensis nourishing as an interesting alternative approach for supporting the conventional treatment of equine metabolic syndrome.

  15. 76 FR 22030 - Third Party Testing for Certain Children's Products; Toddler Beds: Requirements for Accreditation...

    Science.gov (United States)

    2011-04-20

    ... and content of the ILAC-MRA approach and of the requirements of the ISO/IEC 17025:2005 laboratory... to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and.... The product \\1\\ was tested by a third party conformity assessment body that was ISO/IEC 17025...

  16. 75 FR 52616 - Third Party Testing for Certain Children's Products; Youth All-Terrain Vehicles: Requirements for...

    Science.gov (United States)

    2010-08-27

    ... content of the ILAC-MRA approach and of the requirements of the ISO/IEC 17025:2005 laboratory... must be to ISO Standard ISO/IEC 17025:2005, General Requirements for the Competence of Testing and... that at that time was ISO/IEC 17025 accredited by an ILAC-MRA signatory. For firewalled conformity...

  17. Thermal expansion of ThO2-2 wt% UO2 by HT-XRD

    International Nuclear Information System (INIS)

    Tyagi, A.K.; Mathews, M.D.

    2000-01-01

    The linear thermal expansion of polycrystalline ThO 2 -2 wt% UO 2 has been investigated from room temperature to 1473 K in flowing helium atmosphere using high temperature X-ray diffractometry. ThO 2 -2 wt% UO 2 shows a marginally higher linear thermal expansion as compared to pure ThO 2 . The average linear and volume thermal expansion coefficients of ThO 2 -2 wt% UO 2 are found to be α-bar a =9.74x10 -6 K -1 and α-bar v =29.52x10 -6 K -1 (298-1473 K). This study will be useful in designing the nuclear reactor fuel assembly based on ThO 2

  18. Cause analysis for unsatisfactory results in proficiency testing activities: a case study of Brazilian calibration laboratories accredited under ISO/IEC 17025:2005⋆

    Directory of Open Access Journals (Sweden)

    Silva M.A.F.

    2013-01-01

    Full Text Available This work presents the results of a survey carried out among Brazilian calibration laboratories accredited under ISO/IEC 17025:2005 with the objective to identify how these laboratories investigate the root causes of unsatisfactory results in proficiency testing. The survey was coordinated by the Brazilian accreditation body, the General Coordination for Accreditation (Cgcre, of the Institute of Metrology, Quality and Technology (Inmetro.

  19. Importance of pharmaceutical laboratory compliance with international standard requirements in respect of raising their competitiveness

    Directory of Open Access Journals (Sweden)

    Božanić Vojislav N.

    2009-01-01

    Full Text Available Current Good Manufacturing Practice (cGMP being a legal regulation in developed countries will become a legal regulation in Republic of Serbia starting with March 2010. In this paper comparative analysis between requirements of standard ISO/IEC 17025 and requirements of cEU GMP is shown. Considering the fact that in Republic of Serbia no pharmaceutical industry laboratory has been accredited according to requirements of ISO/IEC 17025, while keeping in mind that more than 90% of these laboratories have not fulfilled cEU GMP requirements, this paper aimed at pointing to the possibility of fulfilling both of mentioned requirements at the same time, which would open the way to different types of interlaboratory cooperation for pharmaceutical quality control laboratories and contribute to improving competitiveness of pharmaceutical companies. Accreditation, especially in the case of pharmaceutical quality control laboratories, is important because it guaranties the level of organizational and technical competency. It could easily be said that accreditation is becoming a must in quality control of products in order for the organization to be able to gain a leading role in the global market. Both accreditation and cGMP show the organization's commitment to having products of highest quality level. Considering the above mentioned facts, it is of greatest advantage for pharmaceutical quality control laboratories to fulfill both requirements of ISO/IEC 17025 and cGMP and reach total compliance. The aim of doing this lies in an easier acceptance of pharmaceutical products in different markets, overcoming technical barriers and affirmation of quality as key factor in reaching competitiveness, while keeping in mind the importance of strategic and competitive positioning in the global market.

  20. Low-Volatility Agent Permeation (LVAP) Verification and Validation Report

    Science.gov (United States)

    2015-05-01

    custody procedures were obtained from the ISO / IEC 17025 :2005 standard13 as well as the current version of Permeation and Analytical Solutions Branch...Testing and Calibration Laboratories; ISO / IEC 17025 :2005; International Organization for Standardization: Geneva, Switzerland, 2005. 14. Box, G.E...ECBC, as detailed in Section 6.4.4 The International Organization for Standardization ( ISO ) method, 5725-3 (1994), was used to calculate the standard

  1. A model-driven approach to information security compliance

    Science.gov (United States)

    Correia, Anacleto; Gonçalves, António; Teodoro, M. Filomena

    2017-06-01

    The availability, integrity and confidentiality of information are fundamental to the long-term survival of any organization. Information security is a complex issue that must be holistically approached, combining assets that support corporate systems, in an extended network of business partners, vendors, customers and other stakeholders. This paper addresses the conception and implementation of information security systems, conform the ISO/IEC 27000 set of standards, using the model-driven approach. The process begins with the conception of a domain level model (computation independent model) based on information security vocabulary present in the ISO/IEC 27001 standard. Based on this model, after embedding in the model mandatory rules for attaining ISO/IEC 27001 conformance, a platform independent model is derived. Finally, a platform specific model serves the base for testing the compliance of information security systems with the ISO/IEC 27000 set of standards.

  2. Alternative approach for establishing the Nacelle Transfer Function

    DEFF Research Database (Denmark)

    Krishna, Vinay B.; Ormel, Frank; Hansen, Kurt Schaldemose

    2016-01-01

    The IEC 61400-12-2:2013 is an alternative for all the power performance measurements and analysis when the requirements of the IEC 61400-12-1:2005 are not met. The methodology in the IEC 61400-12-2 standard is solely based on the nacelle anemometry instead of the more traditional methods involving...

  3. 76 FR 49286 - Third Party Testing for Certain Children's Products; Notice of Requirements for Accreditation of...

    Science.gov (United States)

    2011-08-10

    ... history and content of the ILAC-MRA approach and of the requirements of the ISO/IEC 17025:2005 laboratory... be to ISO Standard ISO/IEC 17025:2005, ``General Requirements for the Competence of Testing and..., the product was tested by a third party conformity assessment body that was ISO/IEC 17025 accredited...

  4. Wear properties of Ti-13Zr-13Nb (wt.%) near β titanium alloy containing 0.5 wt.% boron in dry condition, Hank's solution and bovine serum

    International Nuclear Information System (INIS)

    Majumdar, P.; Singh, S.B.; Chakraborty, M.

    2010-01-01

    The effect of heat treatment on the microstructure, hardness and sliding wear behaviour of Ti-13Zr-13Nb (wt.%) containing 0.5 wt.% B (TZNB) has been studied and compared with that of Ti-13Zr-13Nb (wt.%) (TZN) alloy. The wear properties were tested in dry condition and in simulated body fluid (Hank's solution and bovine serum) to understand the effect of different medium on wear behaviour of the TZNB alloy. Depending on the heat treatment condition the microstructure of the alloy consisted of α/martensite and TiB in β matrix. In general, the hardness of all the heat treated samples varied in a narrow range and in most of the cases addition of boron to the TZN alloy decreased the hardness. Almost all cases, no significant variation of the wear rate in dry condition with heat treatment was observed. Compared with the wear rate in dry condition, the wear rate in Hank's solution of the all the TZNB samples increased substantially. Moreover, the wear was found to be most severe in bovine serum. Addition of boron to TZN alloy did not result in any improvement in the wear resistance in all the media studied.

  5. Microstructural and thermophysical properties of U–6 wt.%Zr alloy for fast reactor application

    International Nuclear Information System (INIS)

    Kaity, Santu; Banerjee, Joydipta; Nair, M.R.; Ravi, K.; Dash, Smruti; Kutty, T.R.G.; Kumar, Arun; Singh, R.P.

    2012-01-01

    Highlights: ► Characterization of U–6%Zr alloy prepared by injection casting route. ► Martensitic to non-martensitic transformation of U–6%Zr alloy occurs at 843 K. ► Specific heat versus temperature curve shows a phase transition at 845 K. ► Average coefficient of thermal expansion is 18.28 × 10 −6 K −1 (298–823 K). ► Hardness versus temperature plot shows a transition at 748 K. - Abstract: The microstructural and high temperature behavior of U–6 wt.%Zr alloy has been investigated in this study. U–6 wt.%Zr alloy sample for this study was prepared by following injection casting route. The thermophysical properties like coefficient of thermal expansion, specific heat, thermal conductivity of the above alloy were determined. The hot-hardness data of the U–6 wt.%Zr alloy was also generated from room temperature to 973 K. Apart from that, the fuel-clad chemical compatibility with T91 grade steel was also studied by diffusion couple experiment. No studies have been reported on U–6 wt.%Zr alloy. This paper aims at filling up the gap on characterization and thermophysical property evaluation of U–6 wt.%Zr alloy.

  6. Establishment of a primary standard system for low energy X-rays using a free air ionization chamber; Estabelecimento de um sistema padrao primario para raios-X de energias baixas com uma camara de ionizacao de ar livre

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Natalia Fiorini da

    2016-08-01

    In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was ma de. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI. (author)

  7. General criteria for validation of dosimetry methods in the context of a quality system ISO / IEC 17025

    International Nuclear Information System (INIS)

    Martin Garcia, R.; Navarro Bravo, T.

    2011-01-01

    The accreditation of a testing laboratory in accordance with ISO / IEC 17025 recognizes the technical competence of a laboratory to perform certain tests. One of the requirements of that rule states that laboratories must demonstrate that the methods used are valid and appropriate for the intended use and customer needs. This demonstration is accomplished through the process of validation of methods, defined in the rule it self as c onfirmation by examination and provision of objective evidence that the requirements for a particular purpose . The process of validating a test method should be well planned and documented, including the requirements under the applicable rules and criteria established by the laboratory to comply with these requirements.

  8. IT Security Standards and Legal Metrology – Transfer and Validation

    Directory of Open Access Journals (Sweden)

    Thiel F.

    2014-01-01

    Full Text Available Legal Metrology’s requirements can be transferred into the IT security domain applying a generic set of standardized rules provided by the Common Criteria (ISO/IEC 15408. We will outline the transfer and cross validation of such an approach. As an example serves the integration of Legal Metrology’s requirements into a recently developed Common Criteria based Protection Profile for a Smart Meter Gateway designed under the leadership of the Germany’s Federal Office for Information Security. The requirements on utility meters laid down in the Measuring Instruments Directive (MID are incorporated. A verification approach to check for meeting Legal Metrology’s requirements by their interpretation through Common Criteria’s generic requirements is also presented.

  9. Business Model for the Security of a Large-Scale PACS, Compliance with ISO/27002:2013 Standard.

    Science.gov (United States)

    Gutiérrez-Martínez, Josefina; Núñez-Gaona, Marco Antonio; Aguirre-Meneses, Heriberto

    2015-08-01

    Data security is a critical issue in an organization; a proper information security management (ISM) is an ongoing process that seeks to build and maintain programs, policies, and controls for protecting information. A hospital is one of the most complex organizations, where patient information has not only legal and economic implications but, more importantly, an impact on the patient's health. Imaging studies include medical images, patient identification data, and proprietary information of the study; these data are contained in the storage device of a PACS. This system must preserve the confidentiality, integrity, and availability of patient information. There are techniques such as firewalls, encryption, and data encapsulation that contribute to the protection of information. In addition, the Digital Imaging and Communications in Medicine (DICOM) standard and the requirements of the Health Insurance Portability and Accountability Act (HIPAA) regulations are also used to protect the patient clinical data. However, these techniques are not systematically applied to the picture and archiving and communication system (PACS) in most cases and are not sufficient to ensure the integrity of the images and associated data during transmission. The ISO/IEC 27001:2013 standard has been developed to improve the ISM. Currently, health institutions lack effective ISM processes that enable reliable interorganizational activities. In this paper, we present a business model that accomplishes the controls of ISO/IEC 27002:2013 standard and criteria of security and privacy from DICOM and HIPAA to improve the ISM of a large-scale PACS. The methodology associated with the model can monitor the flow of data in a PACS, facilitating the detection of unauthorized access to images and other abnormal activities.

  10. 9th Annual Systems Engineering Conference: Volume 4 Thursday

    Science.gov (United States)

    2006-10-26

    ISO /IEC 27000 series – Information Security Management System (ISMS) – ISO /IEC 17799:2005 – Code of Practice for Information Security Management...October 2006, Track 2 Standards Organizations Supporting Assurance ISO IEC JTC1TC176 SC1 SC22 Terminology Software Engineering Language, OS SC7...Information Assurance IEEE CS ISO IEC IEEE CS NIST FISMA Projects U.S. Gov’t DoD MIL-STDsPolicy Memos OMG Knowledge Discovery Models OMG 259th Annual

  11. Low temperature bainite in steel with 0.26 wt% C

    Energy Technology Data Exchange (ETDEWEB)

    Soliman, Mohamed, E-mail: mohamed.soliman@tu-clausthal.de [Institute of Metallurgy, Clausthal University of Technology, D38678 Clausthal-Zellerfeld (Germany); Mostafa, Hanaa [Institute of Metallurgy, Clausthal University of Technology, D38678 Clausthal-Zellerfeld (Germany); El-Sabbagh, Ahmed S. [Faculty of Engineering, Ain-Shams University, Cairo (Egypt); Palkowski, Heinz [Institute of Metallurgy, Clausthal University of Technology, D38678 Clausthal-Zellerfeld (Germany)

    2010-11-15

    Research highlights: {yields} Low temperature bainite is produced in 0.26 wt% C steel. {yields} Alloy and process design enable decreasing the carbon content of the alloy. {yields} Generations of bainite are formed at temperatures lower than M{sub S} of the bulk alloy. {yields} Bainite plate thicknesses record values between 90 nm and 164 nm. {yields} Y.S. up to 1570 MPa and U.S. up to 2200 MPa are recorded in compression. - Abstract: Low temperature bainite has been produced in steel with 0.26 wt% C. In this steel the bainite transformation was suppressed, firstly, by adding substitutional solute of about 2 wt% Ni and, secondly, by modifying the conventional single-step bainite transformation. This modification made use of the suppression of martensite start of the undecomposed austenite due to carbon partitioning between that austenite and the formed bainitic ferrite. Consequently, it has been experimentally proved that generations of bainite were formed at temperatures lower than the martensite start of the bulk alloy. Dilatometric measurements were used to design and monitor the bainitic transformation process. The structure was characterized using light optical microscopy, scanning electron microscopy and X-ray diffractometry. In order to investigate the effect of the microstructure parameters on the material's mechanical properties, compression tests have been conducted at room temperature. The results were compared to those obtained by bainitic transformation in single-step process.

  12. Low temperature bainite in steel with 0.26 wt% C

    International Nuclear Information System (INIS)

    Soliman, Mohamed; Mostafa, Hanaa; El-Sabbagh, Ahmed S.; Palkowski, Heinz

    2010-01-01

    Research highlights: → Low temperature bainite is produced in 0.26 wt% C steel. → Alloy and process design enable decreasing the carbon content of the alloy. → Generations of bainite are formed at temperatures lower than M S of the bulk alloy. → Bainite plate thicknesses record values between 90 nm and 164 nm. → Y.S. up to 1570 MPa and U.S. up to 2200 MPa are recorded in compression. - Abstract: Low temperature bainite has been produced in steel with 0.26 wt% C. In this steel the bainite transformation was suppressed, firstly, by adding substitutional solute of about 2 wt% Ni and, secondly, by modifying the conventional single-step bainite transformation. This modification made use of the suppression of martensite start of the undecomposed austenite due to carbon partitioning between that austenite and the formed bainitic ferrite. Consequently, it has been experimentally proved that generations of bainite were formed at temperatures lower than the martensite start of the bulk alloy. Dilatometric measurements were used to design and monitor the bainitic transformation process. The structure was characterized using light optical microscopy, scanning electron microscopy and X-ray diffractometry. In order to investigate the effect of the microstructure parameters on the material's mechanical properties, compression tests have been conducted at room temperature. The results were compared to those obtained by bainitic transformation in single-step process.

  13. 47 CFR 2.962 - Requirements for Telecommunication Certification Bodies.

    Science.gov (United States)

    2010-10-01

    ... well as compliance with applicable parts of the ISO/IEC Standard 17025 and Guide 65, shall be taken...) The certification system shall be based on type testing as identified in sub-clause 1.2(a) of ISO/IEC... accreditation, meet all the appropriate specifications in ISO/IEC Guide 65 for the scope of equipment it will...

  14. Issue of national standards for radiation protection and quality assurance in the medical radiology. Final report; Erstellung von nationalen Normen fuer den Strahlenschutz und die Qualitaetssicherung in der medizinischen Radiologie. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, Bernd

    2012-01-15

    The scope of the project is the issue of national standards for the medical radiology to provide standardized (DIN norms) radiation protection in Germany. Emerging new technologies for instance in the field of information processing and digital techniques are have to be adapted. The standards are supposed to allow the surveillance of medical radiological installations with respect to the technical performance, quality and radiation protection. The project is also aimed to enhance the influence on the European and international standardization and its harmonization (ISO, IEC, CEN, CENELEC) in the fields of radiation protection regulation and X-ray regulation.

  15. Kerangka Investigasi Forensik Pada Peladen Pertukaran Berkas Samba Berdasarkan SNI ISO/IEC 27037:2014

    Directory of Open Access Journals (Sweden)

    Dedy Haryadi

    2017-07-01

    Full Text Available Network File System (NFS dan Common Internet File System (CIFS merupakan protokol yang biasa dipakai dalam melakukan pertukaran berkas di dalam sebuah jaringan komputer yang terhubung dengan Network Attached Storage. Mudahnya dalam bertukar berkas dalam sebuah jaringan tidak menutup kemungkinan adanya pertukaran berkas yang bersifat ilegal ataupun berkas yang mengandung tindak kejahatan. Oleh karena itu, diperlukan sebuah model pendekatan investigasi forensik dalam proses pertukaran berkas di sebuah jaringan komputer. Proses akuisisi dalam penelitian ini dilakukan dengan 2 model, yaitu: akuisisi secara langsung pada mesin peladen file-sharing dan akuisisi secara langsung melalui jaringan. Akuisisi secata langsung pada mesin peladen berfokus pada proses akuisisi log dari mesin peladen yang dihasilkan dari layanan samba dan direktori pertukaran berkas. Akusisi secara langsung melalui jaringan berfokus pada direktori pertukaran berkas yang diakses oleh pengguna. Model akuisisi ini berdasarkan SNI ISO/IEC 27037:2014 tentang Pedoman Identifikasi, Pengumpulan, Akuisisi dan Preservasi Bukti Digital yang fokus pada barang bukti elektronik kritis dengan kondisi tidak diperkenankan mati atau shutdown.

  16. Neutron diffraction study of the deformation mechanisms of the uranium-7 wt.% niobium shape memory alloy

    Energy Technology Data Exchange (ETDEWEB)

    Brown, D.W. [Los Alamos National Lab, Los Alamos, NM 87545 (United States)]. E-mail: dbrown@lanl.gov; Bourke, M.A.M. [Los Alamos National Lab, Los Alamos, NM 87545 (United States); Field, R.D. [Los Alamos National Lab, Los Alamos, NM 87545 (United States); Hults, W.L. [Los Alamos National Lab, Los Alamos, NM 87545 (United States); Teter, D.F. [Los Alamos National Lab, Los Alamos, NM 87545 (United States); Thoma, D.J. [Los Alamos National Lab, Los Alamos, NM 87545 (United States); Vogel, S.C. [Los Alamos National Lab, Los Alamos, NM 87545 (United States)

    2006-04-15

    The shape memory effect (SME) has been reported in the uranium-niobium alloy system in the region of the phase diagram surrounding U-6.5 wt.% Nb. In this regime, the material may have either an {alpha}'' monoclinic (U-6 wt.% Nb), or {gamma}{sup 0} tetragonal structure (U-7 wt.% Nb) and is two phase near 6.5 wt.% niobium. In situ neutron diffraction studies during uniaxial compressive loading of U-7 wt.% Nb indicate that strain in the recoverable region is accommodated by both motion of existing twin boundaries within {gamma}{sup 0}-phase and stress-induced phase transformation from the {gamma}{sup 0} to the {alpha}'' structure. The volume fraction of the {gamma}{sup 0}-phase decreases from 100% initially to {approx}26% after 4% total strain and some reversion is observed on release. The initial stress state of the stress-induced {alpha}'' grains will be discussed as well as the load sharing between the two phases.

  17. SINUPERM N: a new digital neutron flux density monitoring system

    International Nuclear Information System (INIS)

    Flick, H.A.

    1993-01-01

    The new SINUPERM N System is developed for Neutron Monitoring in nuclear power plants. The development was started in 1989 (with the design specification) and will be finished in 1993 (with the qualification). The first built will be the nuclear power plant in Borselle (Netherlands). The design is based on a microprocessor system with a digital signal processor for calculations and signal filtering. The separation between analogue-input signals and digital processing enables for each detector type special input modules and standard output interfaces e.g. field - bus. The wide range of the Neutron Flux Density from 10 -2 cm -2 s -1 up to 10 8 cm -2 s -1 for the out-of-pile instrumentation and up to 10 14 cm -2 s -1 for the in-core-instrumentation will be covered by the SINUPERM N system. The requirements to be met by the SINUPERM N system are the IEEE 323, IEC 987 and the German standard KTA-3503 for safety systems. Other standards for instrumentation and control systems like IEC 801, IEC 1131 and IEC 68 for EMV, climatic and seismic requirements are also included in the hardware type test. The software requirement depends on the IEC 880 standard. (author). 3 figs

  18. 45 CFR 170.499 - Incorporation by reference.

    Science.gov (United States)

    2010-10-01

    ..., Switzerland, telephone +41-22-749-01-11, http://www.iso.org. (1) ISO/IEC 17025 General Requirements for the... and § 170.423. (2) ISO/IEC GUIDE 65 General Requirements for Bodies Operating Product Certification...

  19. FY 1999 project on the development of new industry support type international standards. Standardization for high-interoperability of optical disk systems; 1999 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Hikari disk system no sogo un'yosei kakuho no tame no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The R and D were conducted on the standardization for interoperability of optical disk system, and the FY 1999 results were summarized. In the study, for the volume/file structure specified by ISO/IEC 13346, the development of standards was made for interoperation of the UDF specified by OSTA. In this fiscal year, to avoid the problem on non-interchangeability of UDF which actually exists, enhancement of functions of a test tool for UDF interchangeability was tried. Namely, development was carried out of UDF interchangeability test tool, UAF related standards, and UAF related standards assessment system. Especially, it was formally announced that UDF security enhancement of UAF related standards will be included in UDF2.x in the OSTA conference held at the end of FY 1999. Also, a draft on the standard information was drawn up domestically. The standards including API are expected to be established as standards through activities in the next fiscal year. (NEDO)

  20. FY 1999 project on the development of new industry support type international standards. Standardization for high-interoperability of optical disk systems; 1999 nendo shinki sangyo shiengata kokusai hyojun kaihatsu jigyo seika hokokusho. Hikari disk system no sogo un'yosei kakuho no tame no hyojunka

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The R and D were conducted on the standardization for interoperability of optical disk system, and the FY 1999 results were summarized. In the study, for the volume/file structure specified by ISO/IEC 13346, the development of standards was made for interoperation of the UDF specified by OSTA. In this fiscal year, to avoid the problem on non-interchangeability of UDF which actually exists, enhancement of functions of a test tool for UDF interchangeability was tried. Namely, development was carried out of UDF interchangeability test tool, UAF related standards, and UAF related standards assessment system. Especially, it was formally announced that UDF security enhancement of UAF related standards will be included in UDF2.x in the OSTA conference held at the end of FY 1999. Also, a draft on the standard information was drawn up domestically. The standards including API are expected to be established as standards through activities in the next fiscal year. (NEDO)