WorldWideScience

Sample records for identifying measurement techniques

  1. Testing and evaluation of existing techniques for identifying uptakes and measuring retention of uranium in mill workers

    International Nuclear Information System (INIS)

    1983-03-01

    Preliminary tests and evaluations of existing bio-analytical techniques for identifying uptakes and measuring retention of uranium in mill workers were made at two uranium mills. Urinalysis tests were found to be more reliable indicators of uranium uptakes than personal air sampling. Static air samples were not found to be good indicators of personal uptakes. In vivo measurements of uranium in lung were successfully carried out in the presence of high and fluctuating background radiation. Interference from external contamination was common during end of shift measurements. A full scale study to evaluate model parameters for the uptake, retention and elimination of uranium should include, in addition to the above techniques, particle size determination of airborne uranium, solubility in simulated lung fluid, uranium analysis in faeces and bone and minute volume measurements for each subject

  2. A technique to identify annual growth rings in Eucalyptus grandis using annual measurements of diameter at breast height and gamma ray densitometry

    CSIR Research Space (South Africa)

    Naidoo, Sasha

    2010-06-01

    Full Text Available A technique was developed to identify annual growth rings in E. grandis using a combination of annual measurements of diameter at breast height (DBH) from permanent sample plot (PSP) datasets and bark-pith density profiles. By assessing the pattern...

  3. Spectrometry techniques for radioactivity measurements

    International Nuclear Information System (INIS)

    Anilkumar, S.

    2016-01-01

    The energy of the radiation emission following the nuclear decay is unique and the characteristic of the radio nuclide which undergoes decay. Thus measurement of the energy of the radiation offers a method of identifying the radio nuclides. The prime requirement of the energy measurement is a suitable detector which shows response proportional to the energy of the radiation rather than the presence of the radiation. The response from such detectors are suitably processed and distributed with respect to the signal strength which is proportional to incident energy. This distribution is normally referred as energy spectrum and is recorded in the multichannel analyser. The measurement of energy and intensity of radiation from the spectrum is called radiation spectrometry. Thus the radiation spectrometry allows the identification and quantification of radioactive isotopes in variety of matrices. The radiation spectrometry has now become a popular radioanalytical technique in wide area of nuclear fuel cycle programs. The popular spectrometry techniques commonly used for the radioactivity measurement and analysis are Alpha spectrometry, Gamma ray spectrometry and Beta spectrometry

  4. Pulse holographic measurement techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Baik, Seong Hoon; Hong, Seok Kyung; Kim, Jeong Moog; Kim, Duk Hyun

    1992-01-01

    With the development of laser, remote inspection techniques using laser have been growing on. The inspection and measurement techniques by pulse holography are well-established technique for precise measurement, and widely used in various fields of industry now. In nuclear industry, this technology is practically used because holographic inspection is remote, noncontact, and precise measurement technique. In relation to remote inspection technology in nuclear industry, state-of-the art of pulse HNDT (Holographic non-destructive testing) and holographic measurement techniques are examined. First of all, the fundamental principles as well as practical problems for applications are briefly described. The fields of pulse holography have been divided into the HNDT, flow visualization and distribution study, and other application techniques. Additionally holographic particle study, bubble chamber holography, and applications to other visualization techniques are described. Lastly, the current status for the researches and applications of pulse holography to nuclear industry which are carried out actively in Europe and USA, is described. (Author)

  5. Nuclear techniques to identify allergenic metals in orthodontic brackets

    International Nuclear Information System (INIS)

    Zenobio, E.G.; Zenobio, M.A.F.; Menezes, M.A.B.C.

    2009-01-01

    The present study determines the elementary alloy composition of ten commercial brands of brackets, especially related to Ni, Cr, and Co metals, confirmed allergenic elements. The nuclear techniques applied in the analyses were X-ray fluorescence (XRF) - Centre National de la Recherche Scientifique, France (National Center of Scientific Research), and X-ray energy spectrometry (XRES), and Instrumental Neutron Activation Analysis (INAA) - CDTN/CNEN, Brazil. The XRES and XRF techniques identified Cr in the 10 samples analyzed and Ni in eight samples. The INAA technique identified the presence of Cr (14% to 19%) and Co (42% to 2400 ppm) in all samples. The semi-quantitative analysis performed by XRF also identified Co in two samples. The techniques were effective in the identification of metals in orthodontic brackets. The elements identified in this study can be considered one of the main reason for the allergic processes among the patients studied. This finding suggests that the patients should be tested for allergy and allergenic sensibility to metals prior to the prescription of orthodontic device. (author)

  6. EDITORIAL: Measurement techniques for multiphase flows Measurement techniques for multiphase flows

    Science.gov (United States)

    Okamoto, Koji; Murai, Yuichi

    2009-11-01

    Research on multiphase flows is very important for industrial applications, including power stations, vehicles, engines, food processing and so on. Multiphase flows originally have nonlinear features because of multiphase systems. The interaction between the phases plays a very interesting role in the flows. The nonlinear interaction causes the multiphase flows to be very complicated. Therefore techniques for measuring multiphase flows are very useful in helping to understand the nonlinear phenomena. The state-of-the-art measurement techniques were presented and discussed at the sixth International Symposium on Measurement Techniques for Multiphase Flows (ISMTMF2008) held in Okinawa, Japan, on 15-17 December 2008. This special feature of Measurement Science and Technology includes selected papers from ISMTMF2008. Okinawa has a long history as the Ryukyus Kingdom. China, Japan and many western Pacific countries have had cultural and economic exchanges through Okinawa for over 1000 years. Much technical and scientific information was exchanged at the symposium in Okinawa. The proceedings of ISMTMF2008 apart from these special featured papers were published in Journal of Physics: Conference Series vol. 147 (2009). We would like to express special thanks to all the contributors to the symposium and this special feature. This special feature will be a milestone in measurement techniques for multiphase flows.

  7. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.T.; Sliemers, F.A.; Deringer, G.C.; Wood, V.E.; Wilkes, K.E.; Gaines, G.B.; Carmichael, D.C.

    1978-01-15

    The validation of a service life of 20 years for low-cost photovoltaic arrays must be accomplished through accelerated life-prediction tests. A methodology for such tests has been developed in a preceding study. The results discussed consist of the initial identification and assessment of all known measurement techniques and instruments that might be used in these life-prediction tests. Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories--chemical, electrical, optical, thermal, mechanical, and ''other physicals''. Using specified evaluation criteria, the most promising techniques and instruments for use in life-prediction tests of arrays are then selected. These recommended techniques and their characteristics are described. Recommendations are made regarding establishment of the adequacy, particularly with respect to precision, of the more fully developed techniques for this application, and regarding the experimental evaluation of promising developmental techniques. Measurement needs not satisfied by presently available techniques/instruments are also identified.

  8. The attribute measurement technique

    International Nuclear Information System (INIS)

    MacArthur, Duncan W.; Langner, Diana; Smith, Morag; Thron, Jonathan; Razinkov, Sergey; Livke, Alexander

    2010-01-01

    Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. An information barrier (IB) is included in the measurement system to protect the potentially classified information while allowing sufficient information transfer to occur for the monitoring party to gain confidence that the material being measured is consistent with the host's declarations, concerning that material. The attribute measurement technique incorporates an IB and addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The attribute measurement technique has been implemented in the AVNG, an attribute measuring system described in other presentations at this conference. In this presentation, we will discuss four techniques used in the AVNG: (1) the 1B, (2) the attribute measurement technique, (3) the use of open and secure modes to increase confidence in the displayed results, and (4) the joint design as a method for addressing both host and monitor needs.

  9. Transverse vibration technique to identify deteriorated wood floor systems

    Science.gov (United States)

    R.J. Ross; X. Wang; M.O. Hunt; L.A. Soltis

    2002-01-01

    The Forest Products Laboratory, USDA Forest Service, has been developing nondestructive evaluation (NDE) techniques to identify degradation of wood in structures and the performance characteristics that remain in the structure. This work has focused on using dynamic testing techniques, particularly stress wave and ultrasonic transmission NDE techniques for both...

  10. Advanced in-flight measurement techniques

    CERN Document Server

    Lawson, Nicholas; Jentink, Henk; Kompenhans, Jürgen

    2013-01-01

    The book presents a synopsis of the main results achieved during the 3 year EU-project "Advanced Inflight Measurement Techniques (AIM)" which applied advanced image based measurement techniques to industrial flight testing. The book is intended to be not only an overview on the AIM activities but also a guide on the application of advanced optical measurement techniques for future flight testing. Furthermore it is a useful guide for engineers in the field of experimental methods and flight testing who face the challenge of a future requirement for the development of highly accurate non-intrusive in-flight measurement techniques.

  11. Air flow measurement techniques applied to noise reduction of a centrifugal blower

    Science.gov (United States)

    Laage, John W.; Armstrong, Ashli J.; Eilers, Daniel J.; Olsen, Michael G.; Mann, J. Adin

    2005-09-01

    The air flow in a centrifugal blower was studied using a variety of flow and sound measurement techniques. The flow measurement techniques employed included Particle Image Velocimetry (PIV), pitot tubes, and a five hole spherical probe. PIV was used to measure instantaneous and ensemble-averaged velocity fields over large area of the outlet duct as a function of fan position, allowing for the visualization of the flow as it leave the fan blades and progressed downstream. The results from the flow measurements were reviewed along side the results of the sound measurements with the goal of identifying sources of noise and inefficiencies in flow performance. The radiated sound power was divided into broadband and tone noise and measures of the flow. The changes in the tone and broadband sound were compared to changes in flow quantities such as the turbulent kinetic energy and Reynolds stress. Results for each method will be presented to demonstrate the strengths of each flow measurement technique as well as their limitations. Finally, the role that each played in identifying noise sources is described.

  12. Identifying content-based and relational techniques to change behaviour in motivational interviewing.

    Science.gov (United States)

    Hardcastle, Sarah J; Fortier, Michelle; Blake, Nicola; Hagger, Martin S

    2017-03-01

    Motivational interviewing (MI) is a complex intervention comprising multiple techniques aimed at changing health-related motivation and behaviour. However, MI techniques have not been systematically isolated and classified. This study aimed to identify the techniques unique to MI, classify them as content-related or relational, and evaluate the extent to which they overlap with techniques from the behaviour change technique taxonomy version 1 [BCTTv1; Michie, S., Richardson, M., Johnston, M., Abraham, C., Francis, J., Hardeman, W., … Wood, C. E. (2013). The behavior change technique taxonomy (v1) of 93 hierarchically clustered techniques: Building an international consensus for the reporting of behavior change interventions. Annals of Behavioral Medicine, 46, 81-95]. Behaviour change experts (n = 3) content-analysed MI techniques based on Miller and Rollnick's [(2013). Motivational interviewing: Preparing people for change (3rd ed.). New York: Guildford Press] conceptualisation. Each technique was then coded for independence and uniqueness by independent experts (n = 10). The experts also compared each MI technique to those from the BCTTv1. Experts identified 38 distinct MI techniques with high agreement on clarity, uniqueness, preciseness, and distinctiveness ratings. Of the identified techniques, 16 were classified as relational techniques. The remaining 22 techniques were classified as content based. Sixteen of the MI techniques were identified as having substantial overlap with techniques from the BCTTv1. The isolation and classification of MI techniques will provide researchers with the necessary tools to clearly specify MI interventions and test the main and interactive effects of the techniques on health behaviour. The distinction between relational and content-based techniques within MI is also an important advance, recognising that changes in motivation and behaviour in MI is a function of both intervention content and the interpersonal style

  13. Limitations on the use of the pulsed-wire field-measuring technique

    International Nuclear Information System (INIS)

    Warren, R.W.

    1987-09-01

    As wigglers become longer and the wavelength of the light they produce becomes shorter, the requirements for magnetic field uniformity and precision of wiggler construction become more severe. Techniques used to measure magnetic fields and to estimate the performance of wigglers are now being pushed to their limits in precision and are generally awkward and time consuming in practice. A new field-error measurement technique has been developed that has the usual advantages of a null technique, demonstrates high sensitivity to field errors, and is rapid and simple to employ. With this technique, it appears practical to use computer control to both measure and correct field errors. In a particularly attractive application, these measuring and correcting steps could be carried out on a daily basis for an operational wiggler, which is mounted under vacuum in its optical cavity. In this way, changes in the fields caused by aging or by thermal or radiation-induced deterioration effects could be rapidly identified and corrections could be instituted without significant interruption to normal operations. The principles and limitations of ths technique will be described and examples given of various implementations that have been examined experimentally. 10 refs., 2 figs., 2 tabs

  14. The use of environmental monitoring as a technique to identify isotopic enrichment activities

    International Nuclear Information System (INIS)

    Buchmann, Jose Henrique

    2000-01-01

    The use of environmental monitoring as a technique to identify activities related to the nuclear fuel cycle has been proposed, by international organizations, as an additional measure to the safeguards agreements in force. The elements specific for each kind of nuclear activity, or nuclear signatures, inserted in the ecosystem by several transfer paths, can be intercepted with better or worse ability by different live organisms. Depending on the kind of signature of interest, the anthropogenic material identification and quantification require the choice of adequate biologic indicators and, mainly, the use of sophisticated techniques associated with elaborate sample treatments. This work demonstrates the technical viability of using pine needles as bioindicators of nuclear signatures associated with uranium enrichment activities. Additionally, it proposes the use of a technique widely diffused nowadays in the scientific community, the High Resolution Inductively Coupled Plasma Mass Spectrometer (HR-ICP-MS), to identify the signature corresponding to that kind of activities in the ecosystem. It can be also found a description of a methodology recently being applied in analytical chemistry,based on uncertainties estimates metrological concepts, used to calculate the uncertainties associated with the obtained measurement results. Nitric acid solutions with a concentration of 0.3 mol.kg -1 , used to wash pine needles sampled near facilities that manipulate enriched uranium and containing only 0.1 μg.kg -1 of uranium, exhibit a 235 U: 238 U isotopic abundance ratio of 0.0092±0.0002, while solutions originated from samples collected at places located more than 200 km far from activities related to the nuclear fuel cycle exhibit a value of 0.0074±0.0002 for this abundance ratio. Similar results were obtained for samples collected in different places permit to confirm the presence of anthropogenic uranium and demonstrate the viability of using this technique and the

  15. Magnetic field measurements and mapping techniques

    CERN Multimedia

    CERN. Geneva

    2003-01-01

    These lectures will present an overview of the most common techniques used for the measurement of magnetic field in accelerator magnets. The formalism for a harmonic description of the magnetic field will be presented, including a discussion of harmonics allowed under various types of symmetries in the magnet. The harmonic coil technique for measurement of field harmonics will be covered in depth. Using examples from recent projects, magnetic measurements will be shown to be a powerful tool for monitoring magnet production. Measurements of magnetic axis using extensions of the harmonic coil technique, as well as other techniques, such as the colloidal cell and stretched wire, will be covered. Topics of interest in superconducting magnets, such as time decay and snapback, requiring relatively fast measurements of the harmonics, will also be described.

  16. Radioisotope Sample Measurement Techniques in Medicine and Biology. Proceedings of the Symposium on Radioisotope Sample Measurement Techniques

    International Nuclear Information System (INIS)

    1965-01-01

    The medical and biological applications of radioisotopes depend on two basically different types of measurements, those on living subjects in vivo and those on samples in vitro. The International Atomic Energy Agency has in the past held several meetings on in vivo measurement techniques, notably whole-body counting and radioisotope scanning. The present volume contains the Proceedings of the first Symposium the Agency has organized to discuss the various aspects of techniques for sample measurement in vitro. The range of these sample measurement techniques is very wide. The sample may weigh a few milligrams or several hundred grams, and may be in the gaseous, liquid or solid state. Its radioactive content may consist of a single, known radioisotope or several unknown ones. The concentration of radioactivity may be low, medium or high. The measurements may be made manually or automatically and any one of the many radiation detectors now available may be used. The 53 papers presented at the Symposium illustrate the great variety of methods now in use for radioactive- sample measurements. The first topic discussed is gamma-ray spectrometry, which finds an increasing number of applications in sample measurements. Other sections of the Proceedings deal with: the use of computers in gamma-ray spectrometry and multiple tracer techniques; recent developments in activation analysis where both gamma-ray spectrometry and computing techniques are applied; thin-layer and paper radio chromatographic techniques for use with low energy beta-ray emitters; various aspects of liquid scintillation counting techniques in the measurement of alpha- and beta-ray emitters, including chemical and colour quenching; autoradiographic techniques; calibration of equipment; and standardization of radioisotopes. Finally, some applications of solid-state detectors are presented; this section may be regarded as a preview of important future developments. The meeting was attended by 203 participants

  17. A review on creatinine measurement techniques.

    Science.gov (United States)

    Mohabbati-Kalejahi, Elham; Azimirad, Vahid; Bahrami, Manouchehr; Ganbari, Ahmad

    2012-08-15

    This paper reviews the entire recent global tendency for creatinine measurement. Creatinine biosensors involve complex relationships between biology and micro-mechatronics to which the blood is subjected. Comparison between new and old methods shows that new techniques (e.g. Molecular Imprinted Polymers based algorithms) are better than old methods (e.g. Elisa) in terms of stability and linear range. All methods and their details for serum, plasma, urine and blood samples are surveyed. They are categorized into five main algorithms: optical, electrochemical, impedometrical, Ion Selective Field-Effect Transistor (ISFET) based technique and chromatography. Response time, detection limit, linear range and selectivity of reported sensors are discussed. Potentiometric measurement technique has the lowest response time of 4-10 s and the lowest detection limit of 0.28 nmol L(-1) belongs to chromatographic technique. Comparison between various techniques of measurements indicates that the best selectivity belongs to MIP based and chromatographic techniques. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. The application of a shift theorem analysis technique to multipoint measurements

    OpenAIRE

    M. E. Dieckmann; M. E. Dieckmann; S. C. Chapman

    1999-01-01

    A Fourier domain technique has been proposed previously which, in principle, quantifies the extent to which multipoint in-situ measurements can identify whether or not an observed structure is time stationary in its rest frame. Once a structure, sampled for example by four spacecraft, is shown to be quasi-stationary in its rest frame, the structure's velocity vector can be determined with respect to the sampling spacecraft. We investigate the properties of this technique, wh...

  19. 4. Measuring technique

    International Nuclear Information System (INIS)

    2006-01-01

    It is noted that in nuclear medicine a most widely the scintillation detectors are applying. Action of these detectors is based on registration of light flares in visible and ultraviolet field arising in scintillator under ionizing radiation action. In the chapter following subchapters are included: gamma-spectrometer and gamma radiation detectors; counter of whole body; measuring of accumulated activity (uptake measurements); scanner; scintillation chamber; single-photon emission computed tomography; positron emission computed tomography; magnet resonance tomography; computer technique, images making

  20. Industrial level measurement techniques - a review

    International Nuclear Information System (INIS)

    Schaudel, D.E.

    1984-01-01

    The outlined methods of industrial level measurement technique are nowadays in current use. In correspondence with the technical evolution the mechanical techniques are mentioned first, followed by a description of the more modern electronic methods. These measurement methods comply especially to the requirements of computer aided process guiding systems, i.e. compatibility of signals, self-checking and reliability. (orig.) [de

  1. A Visual Analytics Technique for Identifying Heat Spots in Transportation Networks

    Directory of Open Access Journals (Sweden)

    Marian Sorin Nistor

    2016-12-01

    Full Text Available The decision takers of the public transportation system, as part of urban critical infrastructures, need to increase the system resilience. For doing so, we identified analysis tools for biological networks as an adequate basis for visual analytics in that domain. In the paper at hand we therefore translate such methods for transportation systems and show the benefits by applying them on the Munich subway network. Here, visual analytics is used to identify vulnerable stations from different perspectives. The applied technique is presented step by step. Furthermore, the key challenges in applying this technique on transportation systems are identified. Finally, we propose the implementation of the presented features in a management cockpit to integrate the visual analytics mantra for an adequate decision support on transportation systems.

  2. Current and Ongoing Internet Crime Tendencies and Techniques. Preventive Legislation Measures in Romania

    Directory of Open Access Journals (Sweden)

    Florin Postolache

    2010-06-01

    Full Text Available Internet crime techniques that pilfer from victims millions each year continue to plague the Internet through a range of methods. Trends and techniques identified by many organizations along with itsdescription are followed by preventative measures that will support you in being informed prior to entering into dealings and transactions over the Internet. Techniques as Auction Fraud, Counterfeit Cashier's Check, Credit Card Fraud, Debt Elimination, Parcel Courier Email Scheme, Employment/Business Opportunities,Escrow Services Fraud, Identity Theft, Internet Extortion, Investment Fraud, Lotteries, Nigerian Letter or "419", Phishing/Spoofing, Ponzi/Pyramid, Reshipping, Spam, Third Party Receiver of Funds are clarified in this paper and, also the internet crime prevention and legislative measures are treated, too.

  3. Test plan for suitability assessment of five overcoring stress measurement techniques

    International Nuclear Information System (INIS)

    Gregory, E.C.; Rundle, T.A.; McCabe, W.M.; Kim, K.

    1982-08-01

    Tests are to be conducted at the Near-Surface Test Facility (NSTF) to assess the suitability of five overcoring techniques for in situ stress determination in a jointed basalt. The overcoring methods to be investigated use the following instrumentation to measure strain relief by overcoring a pilot borehole: USBM borehole deformation gage, CSIRO hollow inclusion stress cell, cast epoxy inclusion, the Lulea triaxial strain cell and the ''doorstopper'' biaxial strain cell. The tests are to provide data regarding the state of stress below the NSTF. This information is to be used in the evaluation of each method of overcoring. During the course of field testing, an attempt is to be made to adapt conventional overcoring techniques and analytical methods to the basalt medium. If overcoring stress determination in basalt is shown suitable, then additional studies will be identified to further adapt a technique for use at depth. In addition to the five overcoring techniques to be tested at the NSTF, stress measurements by Hydrofracturing are to be conducted to provide data for direct comparison with overcoring results. 16 refs., 18 figs

  4. Isotope measurement techniques for atmospheric methane

    International Nuclear Information System (INIS)

    Lowe, D.; White, J.; Levin, I.; Wahlen, M.; Miller, J.B.; Bergamaschi, P.

    2002-01-01

    Measurement techniques for the carbon isotopic composition of atmospheric methane (δ 13 C) are described in detail as applied in several leading institutions active in this field since many years. The standard techniques with offline sample preparation and subsequent measurement by dual inlet isotope ratio mass spectrometry (IRMS) are compared with continuous flow IRMS. The potential use of infrared absorption spectroscopy is briefly discussed. Details on quality control and calibration are provided. Basic analytical aspects for the measurement of other species, 2 H and 14 C, are also given. (author)

  5. Innovative High-Accuracy Lidar Bathymetric Technique for the Frequent Measurement of River Systems

    Science.gov (United States)

    Gisler, A.; Crowley, G.; Thayer, J. P.; Thompson, G. S.; Barton-Grimley, R. A.

    2015-12-01

    Lidar (light detection and ranging) provides absolute depth and topographic mapping capability compared to other remote sensing methods, which is useful for mapping rapidly changing environments such as riverine systems. Effectiveness of current lidar bathymetric systems is limited by the difficulty in unambiguously identifying backscattered lidar signals from the water surface versus the bottom, limiting their depth resolution to 0.3-0.5 m. Additionally these are large, bulky systems that are constrained to expensive aircraft-mounted platforms and use waveform-processing techniques requiring substantial computation time. These restrictions are prohibitive for many potential users. A novel lidar device has been developed that allows for non-contact measurements of water depth down to 1 cm with an accuracy and precision of shallow to deep water allowing for shoreline charting, measuring water volume, mapping bottom topology, and identifying submerged objects. The scalability of the technique opens up the ability for handheld or UAS-mounted lidar bathymetric systems, which provides for potential applications currently unavailable to the community. The high laser pulse repetition rate allows for very fine horizontal resolution while the photon-counting technique permits real-time depth measurement and object detection. The enhanced measurement capability, portability, scalability, and relatively low-cost creates the opportunity to perform frequent high-accuracy monitoring and measuring of aquatic environments which is crucial for understanding how rivers evolve over many timescales. Results from recent campaigns measuring water depth in flowing creeks and murky ponds will be presented which demonstrate that the method is not limited by rough water surfaces and can map underwater topology through moderately turbid water.

  6. Hole Drilling Technique – on site stress measurement

    OpenAIRE

    Schueremans, Luc

    2009-01-01

    2. Hole Drilling Technique for onsite stress measurement has been used to validate the stress level at 2 pillars of the Sint-Jacobschurch (Leuven, B). The technique allows estimating the stress in a stone from measuring deformation when a small hole is made. It is a low intrusive technique. The application of it is limited to local stress measurements and is a complement to stress estimate from calculations of from the use of –for example- flat jacks. In addition to the flat-jack technique...

  7. Identifying irradiated flour by photo-stimulated luminescence technique

    International Nuclear Information System (INIS)

    Ros Anita Ahmad Ramli; Muhammad Samudi Yasir; Zainon Othman; Wan Saffiey Wan Abdullah

    2013-01-01

    Full-text: The photo-stimulated luminescence technique is recommended by European Committee for standardization for the detection food irradiation (EN 13751:2009). This study shows on luminescence technique to identify gamma irradiated five types of flour (corn flour, tapioca flour, wheat flour, glutinos rice flour and rice flour) at three difference dose levels in the range 0.2 - 1 kGy. The signal level is compare with two thresholds (700 and 5000). The majority of irradiated samples produce a strong signal above the upper threshold (5000 counts/ 60 s). All the control samples gave negative screening result while the signals below the lower threshold (700 counts/ 60s) suggest that the sample has not been irradiated. A few samples show the signal levels between the two thresholds (intermediate signals) suggest that further investigation. Reported procedure was also tested over 60 days, confirming the applicability and feasibility of proposed methods. (author)

  8. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  9. Measurements Techniques for Gyrotron characterization

    International Nuclear Information System (INIS)

    Castro, P.J. de.

    1987-08-01

    Experiments planned for the characterization of the 35GHz girotron, which is being built at the Plasma Laboratory of INPE, are described. The methods of the measurements are presented and the required instrumentation and devices are specified. Special attention is given to the measurement techniques of the resonator electric field profile. (author) [pt

  10. Experimental techniques of conversion coefficient measurements

    International Nuclear Information System (INIS)

    Hamilton, J.H.

    1975-01-01

    Discusses briefly the history of conversion electron spectra measurements, and the interpretation of the collected data. Then provides a comprehensive review of techniques presently available to measure the conversion coefficients. (Auth.)

  11. Ground-based intercomparison of two isoprene measurement techniques

    Directory of Open Access Journals (Sweden)

    E. Leibrock

    2003-01-01

    Full Text Available An informal intercomparison of two isoprene (C5H8 measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS was compared to a well-established gas chromatographic technique (GC. The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

  12. What's down below? Current and potential future applications of geophysical techniques to identify subsurface permafrost conditions (Invited)

    Science.gov (United States)

    Douglas, T. A.; Bjella, K.; Campbell, S. W.

    2013-12-01

    For infrastructure design, operations, and maintenance requirements in the North the ability to accurately and efficiently detect the presence (or absence) of ground ice in permafrost terrains is a serious challenge. Ground ice features including ice wedges, thermokarst cave-ice, and segregation ice are present in a variety of spatial scales and patterns. Currently, most engineering applications use borehole logging and sampling to extrapolate conditions at the point scale. However, there is high risk of over or under estimating the presence of frozen or unfrozen features when relying on borehole information alone. In addition, boreholes are costly, especially for planning linear structures like roads or runways. Predicted climate warming will provide further challenges for infrastructure development and transportation operations where permafrost degradation occurs. Accurately identifying the subsurface character in permafrost terrains will allow engineers and planners to cost effectively create novel infrastructure designs to withstand the changing environment. There is thus a great need for a low cost rapidly deployable, spatially extensive means of 'measuring' subsurface conditions. Geophysical measurements, both terrestrial and airborne, have strong potential to revolutionize our way of mapping subsurface conditions. Many studies in continuous and discontinuous permafrost have used geophysical measurements to identify discrete features and repeatable patterns in the subsurface. The most common measurements include galvanic and capacitive coupled resistivity, ground penetrating radar, and multi frequency electromagnetic induction techniques. Each of these measurements has strengths, weaknesses, and limitations. By combining horizontal geophysical measurements, downhole geophysics, multispectral remote sensing images, LiDAR measurements, and soil and vegetation mapping we can start to assemble a holistic view of how surface conditions and standoff measurements

  13. Identifying and quantifying energy savings on fired plant using low cost modelling techniques

    International Nuclear Information System (INIS)

    Tucker, Robert; Ward, John

    2012-01-01

    Research highlights: → Furnace models based on the zone method for radiation calculation are described. → Validated steady-state and transient models have been developed. → We show how these simple models can identify the best options for saving energy. → High emissivity coatings predicted to give performance enhancement on a fired heater. → Optimal heat recovery strategies on a steel reheating furnace are predicted. -- Abstract: Combustion in fired heaters, boilers and furnaces often accounts for the major energy consumption on industrial processes. Small improvements in efficiency can result in large reductions in energy consumption, CO 2 emissions, and operating costs. This paper will describe some useful low cost modelling techniques based on the zone method to help identify energy saving opportunities on high temperature fuel-fired process plant. The zone method has for many decades, been successfully applied to small batch furnaces through to large steel-reheating furnaces, glass tanks, boilers and fired heaters on petrochemical plant. Zone models can simulate both steady-state furnace operation and more complex transient operation typical of a production environment. These models can be used to predict thermal efficiency and performance, and more importantly, to assist in identifying and predicting energy saving opportunities from such measures as: ·Improving air/fuel ratio and temperature controls. ·Improved insulation. ·Use of oxygen or oxygen enrichment. ·Air preheating via flue gas heat recovery. ·Modification to furnace geometry and hearth loading. There is also increasing interest in the application of refractory coatings for increasing surface radiation in fired plant. All of the techniques can yield savings ranging from a few percent upwards and can deliver rapid financial payback, but their evaluation often requires robust and reliable models in order to increase confidence in making financial investment decisions. This paper gives

  14. Comparisons between different techniques for measuring mass segregation

    Science.gov (United States)

    Parker, Richard J.; Goodwin, Simon P.

    2015-06-01

    We examine the performance of four different methods which are used to measure mass segregation in star-forming regions: the radial variation of the mass function {M}_MF; the minimum spanning tree-based ΛMSR method; the local surface density ΣLDR method; and the ΩGSR technique, which isolates groups of stars and determines whether the most massive star in each group is more centrally concentrated than the average star. All four methods have been proposed in the literature as techniques for quantifying mass segregation, yet they routinely produce contradictory results as they do not all measure the same thing. We apply each method to synthetic star-forming regions to determine when and why they have shortcomings. When a star-forming region is smooth and centrally concentrated, all four methods correctly identify mass segregation when it is present. However, if the region is spatially substructured, the ΩGSR method fails because it arbitrarily defines groups in the hierarchical distribution, and usually discards positional information for many of the most massive stars in the region. We also show that the ΛMSR and ΣLDR methods can sometimes produce apparently contradictory results, because they use different definitions of mass segregation. We conclude that only ΛMSR measures mass segregation in the classical sense (without the need for defining the centre of the region), although ΣLDR does place limits on the amount of previous dynamical evolution in a star-forming region.

  15. Measurement techniques for radio frequency nanoelectronics

    CERN Document Server

    Wallis, T Mitch

    2017-01-01

    Connect basic theory with real-world applications with this practical, cross-disciplinary guide to radio frequency measurement of nanoscale devices and materials.• Learn the techniques needed for characterizing the performance of devices and their constituent building blocks, including semiconducting nanowires, graphene, and other two dimensional materials such as transition metal dichalcogenides• Gain practical insights into instrumentation, including on-wafer measurement platforms and scanning microwave microscopy• Discover how measurement techniques can be applied to solve real-world problems, in areas such as passive and active nanoelectronic devices, semiconductor dopant profiling, subsurface nanoscale tomography, nanoscale magnetic device engineering, and broadband, spatially localized measurements of biological materialsFeaturing numerous practical examples, and written in a concise yet rigorous style, this is the ideal resource for researchers, practicing engineers, and graduate students new to ...

  16. Least-squares methods for identifying biochemical regulatory networks from noisy measurements

    Directory of Open Access Journals (Sweden)

    Heslop-Harrison Pat

    2007-01-01

    Full Text Available Abstract Background We consider the problem of identifying the dynamic interactions in biochemical networks from noisy experimental data. Typically, approaches for solving this problem make use of an estimation algorithm such as the well-known linear Least-Squares (LS estimation technique. We demonstrate that when time-series measurements are corrupted by white noise and/or drift noise, more accurate and reliable identification of network interactions can be achieved by employing an estimation algorithm known as Constrained Total Least Squares (CTLS. The Total Least Squares (TLS technique is a generalised least squares method to solve an overdetermined set of equations whose coefficients are noisy. The CTLS is a natural extension of TLS to the case where the noise components of the coefficients are correlated, as is usually the case with time-series measurements of concentrations and expression profiles in gene networks. Results The superior performance of the CTLS method in identifying network interactions is demonstrated on three examples: a genetic network containing four genes, a network describing p53 activity and mdm2 messenger RNA interactions, and a recently proposed kinetic model for interleukin (IL-6 and (IL-12b messenger RNA expression as a function of ATF3 and NF-κB promoter binding. For the first example, the CTLS significantly reduces the errors in the estimation of the Jacobian for the gene network. For the second, the CTLS reduces the errors from the measurements that are corrupted by white noise and the effect of neglected kinetics. For the third, it allows the correct identification, from noisy data, of the negative regulation of (IL-6 and (IL-12b by ATF3. Conclusion The significant improvements in performance demonstrated by the CTLS method under the wide range of conditions tested here, including different levels and types of measurement noise and different numbers of data points, suggests that its application will enable

  17. Solar Cell Calibration and Measurement Techniques

    Science.gov (United States)

    Bailey, Sheila; Brinker, Dave; Curtis, Henry; Jenkins, Phillip; Scheiman, Dave

    2004-01-01

    The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WD15387, "Requirements for Measurement and Calibration Procedures for Space Solar Cells" was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and te international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

  18. Neutron flux measurement utilizing Campbell technique

    International Nuclear Information System (INIS)

    Kropik, M.

    2000-01-01

    Application of the Campbell technique for the neutron flux measurement is described in the contribution. This technique utilizes the AC component (noise) of a neutron chamber signal rather than a usually used DC component. The Campbell theorem, originally discovered to describe noise behaviour of valves, explains that the root mean square of the AC component of the chamber signal is proportional to the neutron flux (reactor power). The quadratic dependence of the reactor power on the root mean square value usually permits to accomplish the whole current power range of the neutron flux measurement by only one channel. Further advantage of the Campbell technique is that large pulses of the response to neutrons are favoured over small pulses of the response to gamma rays in the ratio of their mean square charge transfer and thus, the Campbell technique provides an excellent gamma rays discrimination in the current operational range of a neutron chamber. The neutron flux measurement channel using state of the art components was designed and put into operation. Its linearity, accuracy, dynamic range, time response and gamma discrimination were tested on the VR-1 nuclear reactor in Prague, and behaviour under high neutron flux (accident conditions) was tested on the TRIGA nuclear reactor in Vienna. (author)

  19. Thermal measurements and inverse techniques

    CERN Document Server

    Orlande, Helcio RB; Maillet, Denis; Cotta, Renato M

    2011-01-01

    With its uncommon presentation of instructional material regarding mathematical modeling, measurements, and solution of inverse problems, Thermal Measurements and Inverse Techniques is a one-stop reference for those dealing with various aspects of heat transfer. Progress in mathematical modeling of complex industrial and environmental systems has enabled numerical simulations of most physical phenomena. In addition, recent advances in thermal instrumentation and heat transfer modeling have improved experimental procedures and indirect measurements for heat transfer research of both natural phe

  20. Liquidus temperature and optical properties measurement by containerless techniques

    Science.gov (United States)

    Anderson, Collin D.

    1993-01-01

    Reactive alloy liquidus temperatures measured by conventional, contained techniques are often in error due to reactions with containers and gaseous impurities. This paper describes a new liquidus temperature measurement technique that avoids these problems by employing containerless processing. This technique relies on precise and accurate noncontact temperature measurements (NCTM), which are made possible by spectral emissivity values. The spectral emissivities, epsilon(sub lambda), are measured along with the optical properties (real, n, and imaginary, k, components of the index of refraction) using polarimetric techniques on electromagnetically levitated specimens. Results from work done at Vanderbilt University and Intersonics on the Ti-Al system are presented to demonstrate the above techniques.

  1. Development of Measurement Techniques For Strengthening Nuclear Safeguards

    International Nuclear Information System (INIS)

    Badawy, I.

    2007-01-01

    The strategy of nuclear safeguards is based on the accounting and control of nuclear materials, nuclear technologies and activities in a State in order to attain its ''Legal'' goals of the application of atomic energy. The present paper investigates the development in the measurement techniques used in the verification and control of NMs for the purpose of strengthening safeguards. Its focus is to review the recent nuclear measurement techniques used for the identification and verification of nuclear materials.The different levels of verification and the accuracy of these techniques are discussed. The implementation of stregthened safeguards; and nuclear materials verification and control in the world are mentioned. Also, the recently proposed measures to enhance the ability to detect undeclared nuclear materials, nuclear activities and facilities that would need advanced measurement techniques are indicated.

  2. VALUATION TECHNIQUES USED IN FAIR VALUE MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Cristina-Aurora, BUNEA-BONTAS

    2013-12-01

    Full Text Available Valuation of assets and liabilities involves significant judgements and estimates, especially when fair value measurement is required. Currently, IFRS 13 Fair Value Measurement offers a single and more comprehensive source of guidance that is applied to almost all fair value estimates. When measuring fair value of fixed assets, intangible assets, specified financial assets or liabilities, different valuation techniques may be used: the market approach, the cost approach and the income approach. This article reviews these techniques and points out that different valuation practices may provide different results depending on the item being fair valued and on the inputs used. Also it emphasizes that, in particular circumstances, there is the possibility that a certain technique may be more appropriate than other.

  3. Experimental techniques and measurement accuracies

    International Nuclear Information System (INIS)

    Bennett, E.F.; Yule, T.J.; DiIorio, G.; Nakamura, T.; Maekawa, H.

    1985-02-01

    A brief description of the experimental tools available for fusion neutronics experiments is given. Attention is paid to error estimates mainly for the measurement of tritium breeding ratio in simulated blankets using various techniques

  4. Fluid temperature measurement technique by using Raman scattering

    International Nuclear Information System (INIS)

    An, Jeong Soo; Yang, Sun Kyu; Min, Kyung Ho; Chung, Moon Ki; Choi, Young Don

    1999-06-01

    Temperature measurement technique by using Raman scattering was developed for the liquid water at temperature of 20 - 90 degree C and atmospheric pressure. Strong relationship between Raman scattering characteristics and liquid temperature change was observed. Various kinds of measurement techniques, such as Peak Intensity, Peak Wavelength, FWHM (Full Width at Half Maximum), PMCR ( Polymer Monomer Concentration RAte), TSIR (Temperature Sensitive Intensity Ratio), IDIA (Integral Difference Intensity Area) were tested. TSIR has the highest accuracy in mean error or 0.1 deg C and standard deviation of 0.1248 deg C. This report is one of the results in developing process of Raman temperature measurement technique. Next research step is to develop Raman temperature measurement technique at the high temperature and high pressure conditions in single or two phase flows. (author). 13 refs., 3 tabs., 38 figs

  5. Characteristics of Laser Flash Technique for Thermal Diffusivity Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Park, D. G.; Kim, H. M.; Hong, G. P

    2008-08-15

    In relation to selection of thermal conductivity measurement technology, various thermal conductivity measurement technique are investigated for characteristics of each technique and it's measurable range. For the related laser flash techniques, various technical characteristics are reviewed and discussed. Especially, Parker adiabatic model are reviewed because of importance for basic theory of the thermal diffusivity determination. Finite pulse time effect, heat loss effect and non-uniform heating effect, which are main technical factors for laser flash technique, are considered. Finally, characteristics of constituent elements for laser flash measurement system are reviewed and investigated in detail.

  6. Measurement of void fractions by nuclear techniques

    International Nuclear Information System (INIS)

    Hernandez G, A.; Vazquez G, J.; Diaz H, C.; Salinas R, G.A.

    1997-01-01

    In this work it is done a general analysis of those techniques used to determine void fractions and it is chosen a nuclear technique to be used in the heat transfer circuit of the Physics Department of the Basic Sciences Management. The used methods for the determination of void fractions are: radioactive absorption, acoustic techniques, average velocity measurement, electromagnetic flow measurement, optical methods, oscillating absorption, nuclear magnetic resonance, relation between pressure and flow oscillation, infrared absorption methods, sound neutron analysis. For the case of this work it will be treated about the radioactive absorption method which is based in the gamma rays absorption. (Author)

  7. An improved technique for quasi-static C-V measurements

    International Nuclear Information System (INIS)

    Turan, R.; Finstad, T.G.

    1990-10-01

    A new automated quasi-static C-V measurement technique for MOS capacitors has been developed. This techniques uses an integrating electrometer to measure the charge accumulated on a MOS capacitor in response of a small voltage step. Making use of the internal data storage system of a commercial electrometer and a personal computer, the charge Q on the MOS capacitor is measured as a function of time t and stored. The capacitance is then obtained by analyzing this Q-t data set. A Si MOS sample is measured and analyzed in terms of interface charges as an example. Advantages over a commercial quasi-static meter which uses similar measurement technique are presented. It is also shown that this technique is potentially capable of measuring both high and low frequency C-V curves simultaneously. 9 refs. 5 figs

  8. Technique for finding and identifying filters that cut off OTDR lights in front of ONU from a central office

    Science.gov (United States)

    Takaya, Masaaki; Honda, Hiroyasu; Narita, Yoshihiro; Yamamoto, Fumihiko; Arakawa, Koji

    2006-04-01

    We report on a newly developed in-service measurement technique that can be used from a central office to find and identify any filter in front of an ONU on an optical fiber access network. Using this system, in-service tests can be performed because the test lights are modulated at a high frequency. Moreover, by using the equipment we developed, this confirmation operation can be performed continuously and automatically with existing automatic fiber testing systems. The developed technique is effective for constructing a fiber line testing system with an optical time domain reflectometer.

  9. Optimising Regionalisation Techniques: Identifying Centres of Endemism in the Extraordinarily Endemic-Rich Cape Floristic Region

    Science.gov (United States)

    Bradshaw, Peter L.; Colville, Jonathan F.; Linder, H. Peter

    2015-01-01

    We used a very large dataset (>40% of all species) from the endemic-rich Cape Floristic Region (CFR) to explore the impact of different weighting techniques, coefficients to calculate similarity among the cells, and clustering approaches on biogeographical regionalisation. The results were used to revise the biogeographical subdivision of the CFR. We show that weighted data (down-weighting widespread species), similarity calculated using Kulczinsky’s second measure, and clustering using UPGMA resulted in the optimal classification. This maximized the number of endemic species, the number of centres recognized, and operational geographic units assigned to centres of endemism (CoEs). We developed a dendrogram branch order cut-off (BOC) method to locate the optimal cut-off points on the dendrogram to define candidate clusters. Kulczinsky’s second measure dendrograms were combined using consensus, identifying areas of conflict which could be due to biotic element overlap or transitional areas. Post-clustering GIS manipulation substantially enhanced the endemic composition and geographic size of candidate CoEs. Although there was broad spatial congruence with previous phytogeographic studies, our techniques allowed for the recovery of additional phytogeographic detail not previously described for the CFR. PMID:26147438

  10. A technique to identify some typical radio frequency interference using support vector machine

    Science.gov (United States)

    Wang, Yuanchao; Li, Mingtao; Li, Dawei; Zheng, Jianhua

    2017-07-01

    In this paper, we present a technique to automatically identify some typical radio frequency interference from pulsar surveys using support vector machine. The technique has been tested by candidates. In these experiments, to get features of SVM, we use principal component analysis for mosaic plots and its classification accuracy is 96.9%; while we use mathematical morphology operation for smog plots and horizontal stripes plots and its classification accuracy is 86%. The technique is simple, high accurate and useful.

  11. Vessel size measurements in angiograms: A comparison of techniques

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Nazareth, Daryl P.; Miskolczi, Laszlo; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2002-01-01

    As interventional procedures become more complicated, the need for accurate quantitative vascular information increases. In response to this need, many commercial vendors provide techniques for measurement of vessel sizes, usually based on derivative techniques. In this study, we investigate the accuracy of several techniques used in the measurement of vessel size. Simulated images of vessels having circular cross sections were generated and convolved with various focal spot distributions taking into account the magnification. These vessel images were then convolved with Gaussian image detector line spread functions (LSFs). Additionally, images of a phantom containing vessels with a range of diameters were acquired for the 4.5'', 6'', 9'', and 12'' modes of an image intensifier-TV (II-TV) system. Vessel sizes in the images were determined using a first-derivative technique, a second-derivative technique, a linear combination of these two measured sizes, a thresholding technique, a densitometric technique, and a model-based technique. For the same focal spot size, the shape of the focal spot distribution does not affect measured vessel sizes except at large magnifications. For vessels with diameters larger than the full-width-at-half-maximum (FWHM) of the LSF, accurate vessel sizes (errors ∼0.1 mm) could be obtained by using an average of sizes determined by the first and second derivatives. For vessels with diameters smaller than the FWHM of the LSF, the densitometric and model-based techniques can provide accurate vessel sizes when these techniques are properly calibrated

  12. Radiotracer techniques for measuring fluid flow and calibrating flow meters

    International Nuclear Information System (INIS)

    Cooper, E.L.

    1987-08-01

    Radiotracer techniques can be used to measure accurately both gas and liquid flow rates under operating conditions in a wide range of flow systems. They are ideally suited for calibrating flow meters as well as for measuring unmetered flows in industrial plants. Applications of these techniques range from measuring the flows of fuels and process fluids for energy and mass balance studies to measuring the flows of liquid and airborne effluents for pollution control. This report describes the various radiotracer techniques which can be used to measure fluid flows. The range of application and inherent accuracy of each technique is discussed

  13. The Sine Method: An Alternative Height Measurement Technique

    Science.gov (United States)

    Don C. Bragg; Lee E. Frelich; Robert T. Leverett; Will Blozan; Dale J. Luthringer

    2011-01-01

    Height is one of the most important dimensions of trees, but few observers are fully aware of the consequences of the misapplication of conventional height measurement techniques. A new approach, the sine method, can improve height measurement by being less sensitive to the requirements of conventional techniques (similar triangles and the tangent method). We studied...

  14. Critical current measurement in superconducting rings using an automatic inductive technique

    International Nuclear Information System (INIS)

    Gonzalez-Jorge, H.; Linares, B.; Quelle, I.; Carballo, E.; Romani, L.; Domarco, G.

    2007-01-01

    A measurement technique was developed to identify the critical current of superconducting rings. It is based on the detection of the voltage on a secondary coil when the current induced in the superconductor by a primary one go beyond to the critical value. The technique uses a DC power supply to control the AC current circulating by the primary circuit. Such circuit mainly consists on an AC power supply which gives a constant AC voltage, a primary inducting coil and a control coil with iron core. The AC current circulating by this circuit is modified with the change in the impedance of the control coil due to the fact of the DC current supplied by the power supply in parallel with it

  15. Recent developments in magnet measuring techniques

    International Nuclear Information System (INIS)

    Billan, J.; Henrichsen, K.N.; Walckiers, L.

    1985-01-01

    The main problems related to magnetic measurements of particle accelerator components are discussed. Measurements of the properties of magnetic materials as well as the measurements of field distribution in the electromagnets for the Large Electron-Positron Collider (LEP) are illustrated. The fluxmeter method is extensively employed in this work. The impact of recent advances in electronic technology on measurement techniques is explained. Magnetic measurements (including the harmonic coil method) can be performed with improved accuracy applying modern technology to the classical methods. New methods for the non-destructive testing of magnetic materials and for the measurement of magnetic geometry are described. (orig.) [de

  16. An automated technique to identify potential inappropriate traditional Chinese medicine (TCM) prescriptions.

    Science.gov (United States)

    Yang, Hsuan-Chia; Iqbal, Usman; Nguyen, Phung Anh; Lin, Shen-Hsien; Huang, Chih-Wei; Jian, Wen-Shan; Li, Yu-Chuan

    2016-04-01

    Medication errors such as potential inappropriate prescriptions would induce serious adverse drug events to patients. Information technology has the ability to prevent medication errors; however, the pharmacology of traditional Chinese medicine (TCM) is not as clear as in western medicine. The aim of this study was to apply the appropriateness of prescription (AOP) model to identify potential inappropriate TCM prescriptions. We used the association rule of mining techniques to analyze 14.5 million prescriptions from the Taiwan National Health Insurance Research Database. The disease and TCM (DTCM) and traditional Chinese medicine-traditional Chinese medicine (TCMM) associations are computed by their co-occurrence, and the associations' strength was measured as Q-values, which often referred to as interestingness or life values. By considering the number of Q-values, the AOP model was applied to identify the inappropriate prescriptions. Afterwards, three traditional Chinese physicians evaluated 1920 prescriptions and validated the detected outcomes from the AOP model. Out of 1920 prescriptions, 97.1% of positive predictive value and 19.5% of negative predictive value were shown by the system as compared with those by experts. The sensitivity analysis indicated that the negative predictive value could improve up to 27.5% when the model's threshold changed to 0.4. We successfully applied the AOP model to automatically identify potential inappropriate TCM prescriptions. This model could be a potential TCM clinical decision support system in order to improve drug safety and quality of care. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Error reduction techniques for measuring long synchrotron mirrors

    International Nuclear Information System (INIS)

    Irick, S.

    1998-07-01

    Many instruments and techniques are used for measuring long mirror surfaces. A Fizeau interferometer may be used to measure mirrors much longer than the interferometer aperture size by using grazing incidence at the mirror surface and analyzing the light reflected from a flat end mirror. Advantages of this technique are data acquisition speed and use of a common instrument. Disadvantages are reduced sampling interval, uncertainty of tangential position, and sagittal/tangential aspect ratio other than unity. Also, deep aspheric surfaces cannot be measured on a Fizeau interferometer without a specially made fringe nulling holographic plate. Other scanning instruments have been developed for measuring height, slope, or curvature profiles of the surface, but lack accuracy for very long scans required for X-ray synchrotron mirrors. The Long Trace Profiler (LTP) was developed specifically for long x-ray mirror measurement, and still outperforms other instruments, especially for aspheres. Thus, this paper focuses on error reduction techniques for the LTP

  18. Complex technique for materials hardness measurement

    Energy Technology Data Exchange (ETDEWEB)

    Krashchenko, V P; Oksametnaya, O B

    1984-01-01

    A review of existing methods of measurement of material hardness in national and foreign practice has been made. A necessity of improving the technique of material hardness measurement in a wide temperature range and insuring load change with indenting, continuity of imprint application, smooth changing of temperatures along a sample length, and deformation rate control has been noted.

  19. Ultrasonic technique for measuring porosity of plasma-sprayed alumina coatings

    Science.gov (United States)

    Parthasarathi, S.; Tittmann, B. R.; Onesto, E. J.

    1997-12-01

    Porosity is an important factor in plasma-sprayed coatings, especially ceramic coatings. Excessive poros-ity can adversely affect the performance of the coated component in various ways. An ultrasonic nonde-structive measurement technique has been developed to measure porosity in plasma-sprayed alumina coatings. The technique is generic and can be extended to other ceramic coating systems. To test the tech-nique, freestanding alumina coatings with varying levels of porosity were fabricated via plasma spray. Samples with varying porosity, obtained through innovative fabrication techniques, were used to gener-ate a calibration curve. The ultrasonic velocity in the low-frequency range was found to be dependent on the density of freestanding coatings (measured via Archimedian techniques). This dependence is the basis of the development of a technique to measure the density of coatings.

  20. Phase Retrieval Techniques In Coordinates Measurement

    International Nuclear Information System (INIS)

    Harizanova, J. I.; Stoykova, E. V.; Sainov, V. C.

    2007-01-01

    A precise pattern projection profilometry for three-dimensional shape measurements with different methods of fringe generation is presented. The application of phase-shifting algorithm along with two-spacing illumination allow for phase retrieval and estimation of relative and absolute coordinates of the tested samples. The following experimental approaches for fringe generation are investigated: interferometric approach based on a classical Michelson interferometer, digital computation with a DMD projection and light modulation by a sinusoidal phase grating. The theoretical background, experimental results as well as comparison of the applied generation methods are analyzed. The obtained outcomes successfully display the applicability of this technique for surface profile measurement. The application of the proposed techniques for remote, non-destructive in-situ inspection of real objects from cultural heritage is discussed

  1. Spherical near-field antenna measurements — The most accurate antenna measurement technique

    DEFF Research Database (Denmark)

    Breinbjerg, Olav

    2016-01-01

    The spherical near-field antenna measurement technique combines several advantages and generally constitutes the most accurate technique for experimental characterization of radiation from antennas. This paper/presentation discusses these advantages, briefly reviews the early history and present...

  2. [Cholinesterases in total blood measured with a semiquantitative technique, and plasma or erythrocyte cholinesterases measured with quantitative techniques].

    Science.gov (United States)

    Carmona-Fonseca, Jaime

    2007-06-01

    An equivalence model which allows comparison of blood cholinesterase values, measured by Lovibond (semiquantitative technique), and Michel, EQM, Monotest (erythrocyte and plasma cholinesterases) values measured by quantitative techniques is required. The performance of Lovibond (Edson tintometric and Limperos & Ranta techniques) were compared with quantitative techniques. The experimental design was descriptive, cross-sectional, and prospective. From a working population (18-59 years) in Valle de Aburrá and Near East of Antioquia. 827 representative samples were chosen for their lack of exposure to cholinesterase-inhibiting plaguicides and affiliated to the Social Security System. (1) 827 workers were classified by Lovibond in four categories: 821 values with 75% of cholinesterase activity or greater (categories 75, 87.5 and 100%) and 6 with cholinesterase activity smaller than 75%. (2) With each quantitative method, the mean values of erythrocyte and plasmatic cholinesterase corresponding to the four values obtained with Lovibond were statistically different to each other. (3) The mean values of each quantitative technique increased when increased the tintometric method value. (4) Lovibond classified the low enzymatic erythrocyte activity very poorly (61-73%), but the classification of the low enzymatic plasma activity was almost completely in error (94-96%). The values of erythrocyte or plasma cholinesterase were adequately estimated by both the quantitative techniques of Michel and EQM and by Lovibond, but only when the enzymatic activity is normal. Lovibond, however, had a poor capacity to designate as "low" the values that were low according to the quantitative tests.

  3. Optical techniques for in-core measurements

    International Nuclear Information System (INIS)

    Brichard, B.

    2007-01-01

    The in-situ measurement of dimensional changes is a key issue for advanced irradiation programs in Material Test Reactors. It is for example crucial to monitor the changes of the dimensions of nuclear fuel assemblies as well as those of mechanically stressed structural material samples during in-pile irradiations. Different techniques already exist to carry out such measurements but they all come with a number of drawbacks. SCK-CEN and CEA have therefore decided to share the development of a measurement system that was never applied before in the core of a nuclear reactor. It relies on optical dimensional measurements and brings along unprecedented non-intrusiveness combined with high resolution. A clear advantage in using compact optical sensors results in a more efficient occupation of the irradiation volume available for target testings as well as a significant reduction of the gamma-heating associated with the in-pile instrumentation. The objectives of these shared studies are to design, develop, test and qualify an in-pile dimensional measurement system based on optical techniques, with the goal to implement this system in future MTR irradiation experiments. In 2006, we focussed our activities on sensor analysis, selection of the sensor prototypes, procurement and first irradiation experiment

  4. Two-phase flow measurement by pulsed neutron activation techniques

    International Nuclear Information System (INIS)

    Kehler, P.

    1978-01-01

    The Pulsed Neutron Activation (PNA) technique for measuring the mass flow velocity and the average density of two-phase mixtures is described. PNA equipment can be easily installed at different loops, and PNA techniques are non-intrusive and independent of flow regimes. These features of the PNA technique make it suitable for in-situ measurement of two-phase flows, and for calibration of more conventional two-phase flow measurement devices. Analytic relations governing the various PNA methods are derived. The equipment and procedures used in the first air-water flow measurement by PNA techniques are discussed, and recommendations are made for improvement of future tests. In the present test, the mass flow velocity was determined with an accuracy of 2 percent, and average densities were measured down to 0.08 g/cm 3 with an accuracy of 0.04 g/cm 3 . Both the accuracy of the mass flow velocity measurement and the lower limit of the density measurement are functions of the injected activity and of the total number of counts. By using a stronger neutron source and a larger number of detectors, the measurable density can be decreased by a factor of 12 to .007 g/cm 3 for 12.5 cm pipes, and to even lower ranges for larger pipes

  5. Identifying configurations of behavior change techniques in effective medication adherence interventions: a qualitative comparative analysis.

    Science.gov (United States)

    Kahwati, Leila; Viswanathan, Meera; Golin, Carol E; Kane, Heather; Lewis, Megan; Jacobs, Sara

    2016-05-04

    Interventions to improve medication adherence are diverse and complex. Consequently, synthesizing this evidence is challenging. We aimed to extend the results from an existing systematic review of interventions to improve medication adherence by using qualitative comparative analysis (QCA) to identify necessary or sufficient configurations of behavior change techniques among effective interventions. We used data from 60 studies in a completed systematic review to examine the combinations of nine behavior change techniques (increasing knowledge, increasing awareness, changing attitude, increasing self-efficacy, increasing intention formation, increasing action control, facilitation, increasing maintenance support, and motivational interviewing) among studies demonstrating improvements in adherence. Among the 60 studies, 34 demonstrated improved medication adherence. Among effective studies, increasing patient knowledge was a necessary but not sufficient technique. We identified seven configurations of behavior change techniques sufficient for improving adherence, which together accounted for 26 (76 %) of the effective studies. The intervention configuration that included increasing knowledge and self-efficacy was the most empirically relevant, accounting for 17 studies (50 %) and uniquely accounting for 15 (44 %). This analysis extends the completed review findings by identifying multiple combinations of behavior change techniques that improve adherence. Our findings offer direction for policy makers, practitioners, and future comparative effectiveness research on improving adherence.

  6. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  7. Seminar on Detectors and measurements techniques

    International Nuclear Information System (INIS)

    Holm, E.

    2002-01-01

    A Nordic Seminar on detectors and radionuclide measurement techniques was held in Lund, Sweden, May 3-4, 2001. The objective was to highlight recent progress and problems for techniques to study environmental radioactivity. It covered the aspect of detector sample geometry's and methods for evaluation of gamma gamma pulse height distributions. Within the field of alpha-spectrometric techniques gridded ionisation chambers, semiconductor detectors and a general description for analysis of alpha-particle-spectra were presented. Recent development in mass spectrometric techniques, AMS (Accelerator Mass Spectrometry) and ICPMS (Inductively Coupled Plasma mass Spectrometry) for long-lived radionuclides was described. Principles for analysis of beta particle emitters, especially by liquid scintillation were presented. The seminar also covered radiochemistry such advantages and disadvantages between ion exchange, solvent extraction and extraction chromatography. The use of controlled laboratory conditions for discerning the dynamics of accumulation in organisms was demonstrated. Other techniques such as neutron activation were also shown to be useful analytical tool for certain long-lived radionuclides. The results of the intercalibration exercises within the Nordic countries showed the importance of such analytical quality control. (au)

  8. Review of lattice measurement techniques at the SLC

    International Nuclear Information System (INIS)

    Barklow, T.; Emma, P.; Krejcik, P.; Walker, N.

    1991-11-01

    A technique is described for reconstructing the first order transport matrix (R) for a given beam line. Emphasis is placed on the rigorous error analysis of the data, and the use of powerful statistical techniques to estimate unknown systematic errors. The application of the technique to the measurement and subsequent correction of the SLC Arcs is briefly described. 5 refs., 4 figs

  9. Measurement of in-situ stress in salt and rock using NQR techniques

    International Nuclear Information System (INIS)

    Schempp, E.; Hirschfeld, T.; Klainer, S.

    1980-01-01

    A discussion of how stress and strain affect the quantities which can be measured in an NQR experiment shows that, for stresses of the magnitude to be expected at depths up to about 10,000 feet, quadrupole coupling constants will fall in the range of 1 to 10 kHz for both the sodium and chloride ions in NaCl. The most promising system involves pulsed nuclear double resonance detection; and alterative is to observe the quadrupolar splitting of the NMR signal. Choices to be made in the measurement and mapping techniques are discussed. The well-known perturbation of the homogenous stress field in the neighborhood of a borehole is shown to be advantageous from the point of view of obtaining directional information on the stress. Construction and operation of a borehole stress sensor are considered. The NQR technique seems feasible for measuring the magnitude and direction of underground stress with a resolution of about 25 psi, or 2.5% at 1000 psi. Downhole instrumentation suitable for in-situ determinations of stress appears within the state of the art. Additional tasks required on the project are identified

  10. Design techniques for large scale linear measurement systems

    International Nuclear Information System (INIS)

    Candy, J.V.

    1979-03-01

    Techniques to design measurement schemes for systems modeled by large scale linear time invariant systems, i.e., physical systems modeled by a large number (> 5) of ordinary differential equations, are described. The techniques are based on transforming the physical system model to a coordinate system facilitating the design and then transforming back to the original coordinates. An example of a three-stage, four-species, extraction column used in the reprocessing of spent nuclear fuel elements is presented. The basic ideas are briefly discussed in the case of noisy measurements. An example using a plutonium nitrate storage vessel (reprocessing) with measurement uncertainty is also presented

  11. Seminar on Detectors and measurements techniques

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. (ed.) [Risoe National Lab., Roskilde (Denmark)

    2002-07-01

    A Nordic Seminar on detectors and radionuclide measurement techniques was held in Lund, Sweden, May 3-4, 2001. The objective was to highlight recent progress and problems for techniques to study environmental radioactivity. It covered the aspect of detector sample geometry's and methods for evaluation of gamma gamma pulse height distributions. Within the field of alpha-spectrometric techniques gridded ionisation chambers, semiconductor detectors and a general description for analysis of alpha-particle-spectra were presented. Recent development in mass spectrometric techniques, AMS (Accelerator Mass Spectrometry) and ICPMS (Inductively Coupled Plasma mass Spectrometry) for long-lived radionuclides was described. Principles for analysis of beta particle emitters, especially by liquid scintillation were presented. The seminar also covered radiochemistry such advantages and disadvantages between ion exchange, solvent extraction and extraction chromatography. The use of controlled laboratory conditions for discerning the dynamics of accumulation in organisms was demonstrated. Other techniques such as neutron activation were also shown to be useful analytical tool for certain long-lived radionuclides. The results of the intercalibration exercises within the Nordic countries showed the importance of such analytical quality control. (au)

  12. Measuring individual work performance: identifying and selecting indicators.

    Science.gov (United States)

    Koopmans, Linda; Bernaards, Claire M; Hildebrandt, Vincent H; de Vet, Henrica C W; van der Beek, Allard J

    2014-01-01

    Theoretically, individual work performance (IWP) can be divided into four dimensions: task performance, contextual performance, adaptive performance, and counterproductive work behavior. However, there is no consensus on the indicators used to measure these dimensions. This study was designed to (1) identify indicators for each dimension, (2) select the most relevant indicators, and (3) determine the relative weight of each dimension in ratings of work performance. IWP indicators were identified from multiple research disciplines, via literature, existing questionnaires, and expert interviews. Subsequently, experts selected the most relevant indicators per dimension and scored the relative weight of each dimension in ratings of IWP. In total, 128 unique indicators were identified. Twenty-three of these indicators were selected by experts as most relevant for measuring IWP. Task performance determined 36% of the work performance rating, while the other three dimensions respectively determined 22%, 20% and 21% of the rating. Notable consensus was found on relevant indicators of IWP, reducing the number from 128 to 23 relevant indicators. This provides an important step towards the development of a standardized, generic and short measurement instrument for assessing IWP.

  13. Measuring caloric response: comparison of different analysis techniques.

    Science.gov (United States)

    Mallinson, A I; Longridge, N S; Pace-Asciak, P; Ngo, R

    2010-01-01

    Electronystagmography (ENG) testing has been supplanted by newer techniques of measuring eye movement with infrared cameras (VNG). Most techniques of quantifying caloric induced nystagmus measure the slow phase velocity in some manner. Although our analysis is carried out by very experienced assessors, some systems have computer algorithms that have been "taught" to locate and quantify maximum responses. We wondered what differences in measurement might show up when measuring calorics using different techniques and systems, the relevance of this being that if there was a change in slow phase velocity between ENG and VNG testing when measuring caloric response, then normative data would have to be changed. There are also some subjective but important aspects of ENG interpretation which comment on the nature of the response (e.g. responses which might be "sporadic" or "scant"). Our experiment compared caloric responses in 100 patients analyzed four different ways. Each caloric was analyzed by our old ENG system, our new VNG system, an inexperienced assessor and the computer algorithm, and data was compared. All four systems made similar measurements but our inexperienced assessor failed to recognize responses as sporadic or scant, and we feel this is a limitation to be kept in mind in the rural setting, as it is an important aspect of assessment in complex patients. Assessment of complex VNGs should be left to an experienced assessor.

  14. Measurement of mesothelioma on thoracic CT scans: A comparison of manual and computer-assisted techniques

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Oxnard, Geoffrey R.; MacMahon, Heber; Vogelzang, Nicholas J.; Kindler, Hedy L.; Kocherginsky, Masha; Starkey, Adam

    2004-01-01

    Our purpose in this study was to evaluate the variability of manual mesothelioma tumor thickness measurements in computed tomography (CT) scans and to assess the relative performance of six computerized measurement algorithms. The CT scans of 22 patients with malignant pleural mesothelioma were collected. In each scan, an initial observer identified up to three sites in each of three CT sections at which tumor thickness measurements were to be made. At each site, five observers manually measured tumor thickness through a computer interface. Three observers repeated these measurements during three separate sessions. Inter- and intra-observer variability in the manual measurement of tumor thickness was assessed. Six automated measurement algorithms were developed based on the geometric relationship between a specified measurement site and the automatically extracted lung regions. Computer-generated measurements were compared with manual measurements. The tumor thickness measurements of different observers were highly correlated (r≥0.99); however, the 95% limits of agreement for relative inter-observer difference spanned a range of 30%. Tumor thickness measurements generated by the computer algorithms also correlated highly with the average of observer measurements (r≥0.93). We have developed computerized techniques for the measurement of mesothelioma tumor thickness in CT scans. These techniques achieved varying levels of agreement with measurements made by human observers

  15. Optimising the measurement of bruises in children across conventional and cross polarized images using segmentation analysis techniques in Image J, Photoshop and circle diameter measurements.

    Science.gov (United States)

    Harris, C; Alcock, A; Trefan, L; Nuttall, D; Evans, S T; Maguire, S; Kemp, A M

    2018-02-01

    Bruising is a common abusive injury in children, and it is standard practice to image and measure them, yet there is no current standard for measuring bruise size consistently. We aim to identify the optimal method of measuring photographic images of bruises, including computerised measurement techniques. 24 children aged Photoshop 'ruler' software (Photoshop diameter)). Inter and intra-observer effects were determined by two individuals repeating 11 electronic measurements, and relevant Intraclass Correlation Coefficient's (ICC's) were used to establish reliability. Spearman's rank correlation was used to compare in vivo with computerised measurements; a comparison of measurement techniques across imaging modalities was conducted using Kolmogorov-Smirnov tests. Significance was set at p 0.5 for all techniques, with maximum Feret diameter and maximum Photoshop diameter on conventional images having the strongest correlation with in vivo measurements. There were significant differences between in vivo and computer-aided measurements, but none between different computer-aided measurement techniques. Overall, computer aided measurements appeared larger than in vivo. Inter- and intra-observer agreement was high for all maximum diameter measurements (ICC's > 0.7). Whilst there are minimal differences between measurements of images obtained, the most consistent results were obtained when conventional images, segmented by Image J Software, were measured with a Feret diameter. This is therefore proposed as a standard for future research, and forensic practice, with the proviso that all computer aided measurements appear larger than in vivo. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  16. A new technique for infrared scintillation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Chiossi, F., E-mail: federico.chiossi@studenti.unipd.it [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Brylew, K. [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Borghesani, A.F. [CNISM Unit and Dip. di Fisica e Astronomia, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Braggio, C.; Carugno, G. [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Drozdowski, W. [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Guarise, M. [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy)

    2017-05-21

    We propose a new technique to measure the infrared scintillation light yield of rare earth doped crystals by comparing it to near UV–visible scintillation of a calibrated Pr:(Lu{sub 0.75}Y{sub 0.25}){sub 3}Al{sub 5}O{sub 12} sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to 1700 nm of this crystal.

  17. A new technique for infrared scintillation measurements

    International Nuclear Information System (INIS)

    Chiossi, F.; Brylew, K.; Borghesani, A.F.; Braggio, C.; Carugno, G.; Drozdowski, W.; Guarise, M.

    2017-01-01

    We propose a new technique to measure the infrared scintillation light yield of rare earth doped crystals by comparing it to near UV–visible scintillation of a calibrated Pr:(Lu_0_._7_5Y_0_._2_5)_3Al_5O_1_2 sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to 1700 nm of this crystal.

  18. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  19. The measurement of oxygen in vivo using EPR techniques

    International Nuclear Information System (INIS)

    Swartz, Harold M.; Clarkson, Robert B.

    1998-01-01

    The measurement of pO 2 in vivo using EPR has some features which have already led to very useful applications and this approach is likely to have increasingly wide and effective use. It is based on the effect of oxygen on EPR spectra which provides a sensitive and accurate means to measure pO 2 quantitatively. The development of oxygen-sensitive paramagnetic materials which are very stable, combined with instrumental developments, has been crucial to the in vivo applications of this technique. The physical basis and biological applications of in vivo EPR oximetry are reviewed, with particular emphasis on the use of EPR spectroscopy at 1 GHz using particulate paramagnetic materials for the repetitive and non-invasive measurement of pO 2 in tissues. In vivo EPR has already produced some very useful results which have contributed significantly to solving important biological problems. The characteristics of EPR oximetry which appear to be especially useful are often complementary to existing techniques for measuring oxygen in tissues. These characteristics include the capability of making repeated measurements from the same site, high sensitivity to low levels of oxygen, and non-invasive options. The existing techniques are especially useful for studies in small animals, where the depth of measurements is not an overriding issue. In larger animals and potentially in human subjects, non-invasive techniques seem to be immediately applicable to study phenomena very near the surface (within 10 mm) while invasive techniques have some very promising uses. The clinical uses of EPR oximetry which seem especially promising and likely to be undertaken in the near future are long-term monitoring of the status and response to treatment of peripheral vascular disease and optimizing cancer therapy by enabling it to be modified on the basis of the pO 2 measured in the tumour. (author)

  20. Review of nuclear data improvement needs for nuclear radiation measurement techniques used at the CEA experimental reactor facilities

    Directory of Open Access Journals (Sweden)

    Destouches Christophe

    2016-01-01

    Full Text Available The constant improvement of the neutron and gamma calculation codes used in experimental nuclear reactors goes hand in hand with that of the associated nuclear data libraries. The validation of these calculation schemes always requires the confrontation with integral experiments performed in experimental reactors to be completed. Nuclear data of interest, straight as cross sections, or elaborated ones such as reactivity, are always derived from a reaction rate measurement which is the only measurable parameter in a nuclear sensor. So, in order to derive physical parameters from the electric signal of the sensor, one needs specific nuclear data libraries. This paper presents successively the main features of the measurement techniques used in the CEA experimental reactor facilities for the on-line and offline neutron/gamma flux characterizations: reactor dosimetry, neutron flux measurements with miniature fission chambers and Self Power Neutron Detector (SPND and gamma flux measurements with chamber ionization and TLD. For each technique, the nuclear data necessary for their interpretation will be presented, the main identified needs for improvement identified and an analysis of their impact on the quality of the measurement. Finally, a synthesis of the study will be done.

  1. Radiometric measurement techniques in metallurgy and foundry technology

    International Nuclear Information System (INIS)

    1990-01-01

    The contributions contain informations concerning the present state and development of radiometric measurement techniques in metallurgy and foundry technology as well as their application to the solution of various problems. The development of isotope techniques is briefly described. Major applications of radiometric equipment in industrial measurement are presented together with the use of isotopes to monitor processes of industrial production. This is followed by a short description of numerous laboratory-scale applications. Another contribution deals with fundamental problems and methods of moisture measurement by neutrons. A complex moisture/density measurement device the practical applicability of which has been tested is described here. Possibilities for clay determination in used-up moulding materials are discussed in a further contribution. The clay content can be determined by real-time radiometric density measurement so that the necessary moisture or addition of fresh sand can be controlled. (orig.) With 20 figs., 9 tabs., 178 refs [de

  2. Proceedings of the OECD/CSNI specialist meeting on advanced instrumentation and measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, J [comp.

    1998-09-01

    In the last few years, tremendous advances in the local instrumentation technology for two-phase flow have been accomplished by the applications of new sensor techniques, optical or beam methods and electronic technology. The detailed measurements gave new insight to the true nature of local mechanisms of interfacial transfer between phases, interfacial structure and two-phase flow turbulent transfers. These new developments indicate that more accurate and reliable two-phase flow models can be obtained, if focused experiments are designed and performed by utilizing this advanced instrumentation. The purpose of this Specialist Meeting on Advanced Instrumentation and Measurement Techniques was to review the recent instrumentation developments and the relation between thermal-hydraulic codes and instrumentation capabilities. Four specific objectives were identified for this meeting: bring together international experts on instrumentation, experiments, and modeling; review recent developments in multiphase flow instrumentation; discuss the relation between modeling needs and instrumentation capabilities, and discuss future directions for instrumentation development, modeling, and experiments.

  3. Proceedings of the OECD/CSNI specialist meeting on advanced instrumentation and measurement techniques

    International Nuclear Information System (INIS)

    Lehner, J.

    1998-09-01

    In the last few years, tremendous advances in the local instrumentation technology for two-phase flow have been accomplished by the applications of new sensor techniques, optical or beam methods and electronic technology. The detailed measurements gave new insight to the true nature of local mechanisms of interfacial transfer between phases, interfacial structure and two-phase flow turbulent transfers. These new developments indicate that more accurate and reliable two-phase flow models can be obtained, if focused experiments are designed and performed by utilizing this advanced instrumentation. The purpose of this Specialist Meeting on Advanced Instrumentation and Measurement Techniques was to review the recent instrumentation developments and the relation between thermal-hydraulic codes and instrumentation capabilities. Four specific objectives were identified for this meeting: bring together international experts on instrumentation, experiments, and modeling; review recent developments in multiphase flow instrumentation; discuss the relation between modeling needs and instrumentation capabilities, and discuss future directions for instrumentation development, modeling, and experiments

  4. Intercomparison of techniques for the non-invasive measurement of bone mass

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1981-01-01

    A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques

  5. Identifying and correcting epigenetics measurements for systematic sources of variation.

    NARCIS (Netherlands)

    Perrier, Flavie; Novoloaca, Alexei; Ambatipudi, Srikant; Baglietto, Laura; Ghantous, Akram; Perduca, Vittorio; Barrdahl, Myrto; Harlid, Sophia; Ong, Ken K; Cardona, Alexia; Polidoro, Silvia; Nøst, Therese Haugdahl; Overvad, Kim; Omichessan, Hanane; Dollé, Martijn; Bamia, Christina; Huerta, José Marìa; Vineis, Paolo; Herceg, Zdenko; Romieu, Isabelle; Ferrari, Pietro

    2018-01-01

    Methylation measures quantified by microarray techniques can be affected by systematic variation due to the technical processing of samples, which may compromise the accuracy of the measurement process and contribute to bias the estimate of the association under investigation. The quantification of

  6. New technique of identifying the hierarchy of dynamic domains in proteins using a method of molecular dynamics simulations

    Directory of Open Access Journals (Sweden)

    Yesylevskyy S. O.

    2010-04-01

    Full Text Available Aim. Despite a large number of existing domain identification techniques there is no universally accepted method, which identifies the hierarchy of dynamic domains using the data of molecular dynamics (MD simulations. The goal of this work is to develop such technique. Methods. The dynamic domains are identified by eliminating systematic motions from MD trajectories recursively in a model-free manner. Results. The technique called the Hierarchical Domain-Wise Alignment (HDWA to identify hierarchically organized dynamic domains in proteins using the MD trajectories has been developed. Conclusion. A new method of domain identification in proteins is proposed

  7. Uncertainties in assessing tillage erosion - How appropriate are our measuring techniques?

    Science.gov (United States)

    Fiener, P.; Wilken, F.; Aldana-Jague, E.; Deumlich, D.; Gómez, J. A.; Guzmán, G.; Hardy, R. A.; Quinton, J. N.; Sommer, M.; Van Oost, K.; Wexler, R.

    2018-03-01

    Tillage erosion on arable land is a very important process leading to a net downslope movement of soil and soil constitutes. Tillage erosion rates are commonly in the same order of magnitude as water erosion rates and can be even higher, especially under highly mechanized agricultural soil management. Despite its prevalence and magnitude, tillage erosion is still understudied compared to water erosion. The goal of this study was to bring together experts using different techniques to determine tillage erosion and use the different results to discuss and quantify uncertainties associated with tillage erosion measurements. The study was performed in northeastern Germany on a 10 m by 50 m plot with a mean slope of 8%. Tillage erosion was determined after two sequences of seven tillage operations. Two different micro-tracers (magnetic iron oxide mixed with soil and fluorescent sand) and one macro-tracer (passive radio-frequency identification transponders (RFIDs), size: 4 × 22 mm) were used to directly determine soil fluxes. Moreover, tillage induced changes in topography were measured for the entire plot with two different terrestrial laser scanners and an unmanned aerial system for structure from motion topography analysis. Based on these elevation differences, corresponding soil fluxes were calculated. The mean translocation distance of all techniques was 0.57 m per tillage pass, with a relatively wide range of mean soil translocation distances ranging from 0.39 to 0.72 m per pass. A benchmark technique could not be identified as all used techniques have individual error sources, which could not be quantified. However, the translocation distances of the macro-tracers used were consistently smaller than the translocation distances of the micro-tracers (mean difference = - 26 ± 12%), which questions the widely used assumption of non-selective soil transport via tillage operations. This study points out that tillage erosion measurements, carried out under almost

  8. Trial on MR portal blood flow measurement with phase contrast technique

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Togami, Izumi

    1991-01-01

    Portal blood flow measurement is considered to be important for the analysis of hemodynamics in various liver diseases. The Doppler ultrasound method has been used extensively during the past several years for measuring portal blood flow, as a non-invasive method. However, the Doppler ultrasound technique do not allow the portal blood flow to be measured in cases of obesity, with much intestinal gas, and so on. In this study, we attempted to measure the blood flow in the main trunk of portal vein as an application of MR phase contrast technique to the abdominal region. In the flow phantom study, the flow volumes and the velocities measured by phase contrast technique showed a close correlation with those measured by electromagnetic flowmeter. In the clinical study with 10 healthy volunteers, various values of portal blood flow were obtained. Mean portal blood flow could be measured within the measuring time (about 8 minutes) under natural breathing conditions. Phase contrast technique is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  9. Development of a computational technique to measure cartilage contact area.

    Science.gov (United States)

    Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A

    2014-03-21

    Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Sound Power Estimation by Laser Doppler Vibration Measurement Techniques

    Directory of Open Access Journals (Sweden)

    G.M. Revel

    1998-01-01

    Full Text Available The aim of this paper is to propose simple and quick methods for the determination of the sound power emitted by a vibrating surface, by using non-contact vibration measurement techniques. In order to calculate the acoustic power by vibration data processing, two different approaches are presented. The first is based on the method proposed in the Standard ISO/TR 7849, while the second is based on the superposition theorem. A laser-Doppler scanning vibrometer has been employed for vibration measurements. Laser techniques open up new possibilities in this field because of their high spatial resolution and their non-intrusivity. The technique has been applied here to estimate the acoustic power emitted by a loudspeaker diaphragm. Results have been compared with those from a commercial Boundary Element Method (BEM software and experimentally validated by acoustic intensity measurements. Predicted and experimental results seem to be in agreement (differences lower than 1 dB thus showing that the proposed techniques can be employed as rapid solutions for many practical and industrial applications. Uncertainty sources are addressed and their effect is discussed.

  11. An advanced ultrasonic technique for slow and void fraction measurements of two-phase flow

    International Nuclear Information System (INIS)

    Faccini, J.L.H.; Su, J.; Harvel, G.D.; Chang, J.S.

    2004-01-01

    In this paper, we present a hybrid type counterpropagating transmission ultrasonic technique (CPTU) for flow and time averaging ultrasonic transmission intensity void fraction measurements (TATIU) of air-water two-phase flow, which is tested in the new two-phase flow test section mounted recently onto an existing single phase flow rig. The circular pipe test section is made of 51.2 mm stainless steel, followed by a transparent extruded acrylic pipe aimed at flow visualization. The two-phase flow rig operates in several flow regimes: bubbly, smooth stratified, wavy stratified and slug flow. The observed flow patterns are compared with previous experimental and numerical flow regime map for horizontal two phase flows. These flow patterns will be identified by time averaging transmission intensity ultrasonic techniques which have been developed to meet this particular application. A counterpropagating transmission ultrasonic flowmeter is used to measure the flow rate of liquid phase. A pulse-echo TATIU ultrasonic technique used to measure the void fraction of the horizontal test section is presented. We can draw the following conclusions: 1) the ultrasonic system was able to characterize the 2 flow patterns simulated (stratified and plug flow); 2) the results obtained for water volumetric fraction require more experimental work to determine exactly the technique uncertainties but, a priori, they are consistent with earlier work; and 3) the experimental uncertainties can be reduced by improving the data acquisition system, changing the acquisition time interval from seconds to milliseconds

  12. Measurement techniques for radiological characterization of contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Loos, M

    1996-09-18

    Once the decision is taken to characterize a contaminated site, appropriate measurement techniques must be selected. The choice will depend on the available information, on the nature and extent of the contamination, as well as on available resources (staff and budget). Some techniques are described on the basis of examples of characterization projects (e.g. Olen area in Belgium).

  13. Measurement technique developments for LBE flows

    Energy Technology Data Exchange (ETDEWEB)

    Buchenau, D., E-mail: d.buchenau@fzd.de [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); Eckert, S.; Gerbeth, G. [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); Stieglitz, R. [Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany); Dierckx, M. [SCK-CEN, Belgian Nuclear Research Centre, 2400 Mol (Belgium)

    2011-08-31

    We report on the development of measurement techniques for flows in lead-bismuth eutectic alloys (LBE). This paper covers the test results of newly developed contactless flow rate sensors as well as the development and test of the LIDAR technique for operational free surface level detection. The flow rate sensors are based on the flow-induced disturbance of an externally applied AC magnetic field which manifests itself by a modified amplitude or a modified phase of the AC field. Another concept of a force-free contactless flow meter uses a single cylindrical permanent magnet. The electromagnetic torque on the magnet caused by the liquid metal flow sets the magnet into rotation. The operation of those sensors has been demonstrated at liquid metal test loops for which comparative flow rate measurements are available, as well as at the LBE loops THESYS at KIT and WEBEXPIR at SCK-CEN. For the level detection a commercial LIDAR system was successfully tested at the WEBEXPIR facility in Mol and the THEADES loop in Karlsruhe.

  14. Measurement techniques and safety culture in radiation protection -reflections after 37 years of occupation with measuring instruments

    International Nuclear Information System (INIS)

    Maushart, R.

    1994-01-01

    Safety Culture in radiation use and radiation protection implies primarily knowledge and competence of the decision makers. As the measuring techniques are basic for practical radiation protection, only such person can be called competent who has sufficient expertise on measuring techniques, and is able to evaluate its application and results. Safety Culture also implies the readiness to expose errors, and to learn from them. ''Believing in infallibility'' excludes Safety Culture. Therefore, correctly applied measuring technique contributes to recognize weak points early. How far it is used consciously and actively to prevent undesirable developments and exceeding of limits, can be considered outright as a yardstick for a high-ranking safety culture. Safety Culture as a whole, however, needs more than more measuring techniques. It requires its own and adequate Measurement Culture, presupposing also motivation and determination to measure. Therefore, education, training, knowledge and consciousness of safety of the people who are responsible for measurements are decisive for successful radiation protection. (orig.) [de

  15. Demonstration of relatively new electron dosimetry measurement techniques on the Mevatron 80

    International Nuclear Information System (INIS)

    Meyer, J.A.; Palta, J.R.; Hogstrom, K.R.

    1984-01-01

    A comprehensive set of electron dosimetry measurements at 7, 10, 12, 15, and 18 MeV was made on a Mevatron 80. Dosimetry measurements presented include percentage depth dose, dose in the buildup region, field size dependence of output, output at extended distances, lead transmission measurements, and isodose curves. These beam measurements are presented to document the electron beam characteristics of this linear accelerator. Three relatively new dosimetry techniques, which have not been standardly used in the past, are illustrated. One technique determines the depth dose of fields too small to measure. A second technique accurately converts depth dose measured in polystyrene to depth dose in water. A third technique calculates the output at extended distances

  16. Comparison of non-invasive tear film stability measurement techniques.

    Science.gov (United States)

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  17. Measurements of uranium enrichment by four techniques of gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Tojo, Takao

    1983-12-01

    Measurements of uranium enrichment with the uses of the LMRI (France) UO 2 standards have been made by four techniques of gamma-ray spectrometry, in order to examine measurement characteristics of each technique. The following results were obtained by the three techniques based on the direct determination of the peak area of the 186-keV gamma-rays from 235 U, when the standard sample of 6.297 a/o was used for measuring enrichments ranging from 1.4 a/o to 9.6 a/o ; (i) In a LEPS HP Ge gamma-ray spectrometry, standard deviation of the measured enrichments from the certified ones was 1.4 %, (ii) in a Ge(Li) gamma-ray spectrometry, the standard deviation was 2.0 %, (iii) in a NaI(Tl) gamma-ray spectrometry, the standard deviation was 1.2 %. In the fourth technique, the method of multiple single-channel analyzers, enrichments of 1.4 - 9.6 a/o were measured in the standard deviation of 0.51 %, when the most suitable pairs of standard samples were used for each sample. A part of sources of systematic errors which were caused by each technique adopted was revealed throughout the measurements. And also, it was recognized that the LMRI's values of enrichment were certified precisely, and the UO 2 standards were very useful for enrichment measurements in the four techniques of gamma-ray spectrometry used here. (author)

  18. Techniques de débitmétrie polyphasique non intrusive. Revue bibliographique Non Intrusive Multiphase Flow Measurement Techniques. Bibliographic Review

    Directory of Open Access Journals (Sweden)

    Lynch J.

    2006-11-01

    . Parameters permitting the various phases to be discriminated are identified in order to evaluate the various techniques. The latter are classified in two major families of interaction for which a range of frequencies are explored : mechanical interactions from ultrasound to simple pressure and noisemeasurement and electromagnetic interactions from the use of gamma rays to the measurement of static electrical properties. Consideration is also given to two techniques of special interest falling outside this classification : the use of neutron bombardment and that of nuclear magnetic resonance (NMR. Most of the techniques considered give only partial responses to the question of measuring the quantites and velocities of each of the three major components : oil water and gas. Some, such as visible light or infrared spectroscopy, are eliminated entirely due to the local nature of the measurements in the system considered. Methods such as acoustic or pressure measurement, providing a rapid and simple means of detecting major events such as the passage of slugs and gas pockets and of measuring their velocity in favorable cases, may be incorporated into the final system. Little information is however furnished as to the flow rates of individual components. Four types of measurement have been selected as presenting particular advantages in all or part of the range of parameters for which information is required. Neutron based methods, particularly when coupled to induced gamma ray spectroscopy, promise to provide useful information on water/oil ratios and on salinity although the development of practical sources is as yet only in its earliest stage. NMR is potentially capable of providing independant measurements of both the quantity and velocity of the two liquid phases although the size of such a flowmeter would be prohibitive in the application envisaged. A restricted application (both in terms of size and in the number of measured parameters may however be advantageous in

  19. The application of a shift theorem analysis technique to multipoint measurements

    Directory of Open Access Journals (Sweden)

    M. E. Dieckmann

    Full Text Available A Fourier domain technique has been proposed previously which, in principle, quantifies the extent to which multipoint in-situ measurements can identify whether or not an observed structure is time stationary in its rest frame. Once a structure, sampled for example by four spacecraft, is shown to be quasi-stationary in its rest frame, the structure's velocity vector can be determined with respect to the sampling spacecraft. We investigate the properties of this technique, which we will refer to as a stationarity test, by applying it to two point measurements of a simulated boundary layer. The boundary layer was evolved using a PIC (particle in cell electromagnetic code. Initial and boundary conditions were chosen such, that two cases could be considered, i.e. a spacecraft pair moving through (1 a time stationary boundary structure and (2 a boundary structure which is evolving (expanding in time. The code also introduces noise in the simulated data time series which is uncorrelated between the two spacecraft. We demonstrate that, provided that the time series is Hanning windowed, the test is effective in determining the relative velocity between the boundary layer and spacecraft and in determining the range of frequencies over which the data can be treated as time stationary or time evolving. This work presents a first step towards understanding the effectiveness of this technique, as required in order for it to be applied to multispacecraft data.

    Key words. Electromagnetics (wave propagation · Radio science (waves in plasma · Space plasma physics (active perturbation experiments.

  20. The application of a shift theorem analysis technique to multipoint measurements

    Directory of Open Access Journals (Sweden)

    M. E. Dieckmann

    1999-03-01

    Full Text Available A Fourier domain technique has been proposed previously which, in principle, quantifies the extent to which multipoint in-situ measurements can identify whether or not an observed structure is time stationary in its rest frame. Once a structure, sampled for example by four spacecraft, is shown to be quasi-stationary in its rest frame, the structure's velocity vector can be determined with respect to the sampling spacecraft. We investigate the properties of this technique, which we will refer to as a stationarity test, by applying it to two point measurements of a simulated boundary layer. The boundary layer was evolved using a PIC (particle in cell electromagnetic code. Initial and boundary conditions were chosen such, that two cases could be considered, i.e. a spacecraft pair moving through (1 a time stationary boundary structure and (2 a boundary structure which is evolving (expanding in time. The code also introduces noise in the simulated data time series which is uncorrelated between the two spacecraft. We demonstrate that, provided that the time series is Hanning windowed, the test is effective in determining the relative velocity between the boundary layer and spacecraft and in determining the range of frequencies over which the data can be treated as time stationary or time evolving. This work presents a first step towards understanding the effectiveness of this technique, as required in order for it to be applied to multispacecraft data.Key words. Electromagnetics (wave propagation · Radio science (waves in plasma · Space plasma physics (active perturbation experiments.

  1. An intensity-monitoring technique for measuring ellipsometric transients

    NARCIS (Netherlands)

    Droog, J.M.M.; Bootsma, G.A.

    1979-01-01

    Intensity-monitoring techniques make possible the measurement of rapid changes in the ellipsometric parameters. Methods used hitherto have been suitable for measuring slight changes only and require prior knowledge of the Δ and Ψ values for the initial surface. It is shown that larger changes can

  2. Unit vent airflow measurements using a tracer gas technique

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.G. [Union Electric Company, Fulton, MO (United States); Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); Fleming, K.M. [NCS Corp., Columbus, OH (United States)

    1997-08-01

    An alternative method for assessing flowrates that does not depend on point measurements of air flow velocity is the constant tracer injection technique. In this method one injects a tracer gas at a constant rate into a duct and measures the resulting concentration downstream of the injection point. A simple equation derived from the conservation of mass allows calculation of the flowrate at the point of injection. Flowrate data obtained using both a pitot tube and a flow measuring station were compared with tracer gas flowrate measurements in the unit vent duct at the Callaway Nuclear Station during late 1995 and early 1996. These data are presented and discussed with an eye toward obtaining precise flowrate data for release rate calculations. The advantages and disadvantages of the technique are also described. In those test situations for which many flowrate combinations are required, or in large area ducts, a tracer flowrate determination requires fewer man-hours than does a conventional traverse-based technique and does not require knowledge of the duct area. 6 refs., 10 figs., 6 tabs.

  3. Measurement of epithermal neutrons by a coherent demodulation technique

    CERN Document Server

    Horiuchi, N; Takahashi, H; Kobayashi, H; Harasawa, S

    2000-01-01

    Epithermal neutrons have been measured using a neutron dosimeter via a coherent demodulation technique. This dosimeter consists of CsI(Tl)-photodiode scintillation detectors, four of which are coupled to neutron-gamma converting foils of various sizes. Neutron-gamma converting foils of In, Au and Co materials were used, each of which has a large capture cross section which peaks in the epithermal neutron energy region. The type of foil was selected according to the material properties that best correspond to the energy of the epithermal neutrons to be measured. In addition, the proposed technique was applied using Au-foils in order to measure the Cd ratio. The validity of the proposed technique was examined using an sup 2 sup 4 sup 1 Am-Be source placed in a testing stack of polyethylene blocks, and the results were compared with the theoretical values calculated by the Monte Carlo calculation. Finally, the dosimeter was applied for measuring epithermal neutrons and the Cd ratio in an experimental beam-tube o...

  4. Techniques For Measuring Absorption Coefficients In Crystalline Materials

    Science.gov (United States)

    Klein, Philipp H.

    1981-10-01

    Absorption coefficients smaller than 0.001 cm-1 can, with more or less difficulty, be measured by several techniques. With diligence, all methods can be refined to permit measurement of absorption coefficients as small as 0.00001 cm-1. Spectral data are most readily obtained by transmission (spectrophotometric) methods, using multiple internal reflection to increase effective sample length. Emissivity measurements, requiring extreme care in the elimination of detector noise and stray light, nevertheless afford the most accessible spectral data in the 0.0001 to 0.00001 cm-1 range. Single-wavelength informa-tion is most readily obtained with modifications of laser calorimetry. Thermo-couple detection of energy absorbed from a laser beam is convenient, but involves dc amplification techniques and is susceptible to stray-light problems. Photoacoustic detection, using ac methods, tends to diminish errors of these types, but at some expense in experimental complexity. Laser calorimetry has been used for measurements of absorption coefficients as small as 0.000003 cm-1. Both transmission and calorimetric data, taken as functions of intensity, have been used for measurement of nonlinear absorption coefficients.

  5. Technique for measurements of plane waves of uniaxial strain

    International Nuclear Information System (INIS)

    Graham, R.A.

    1977-01-01

    The measurement of plane waves in uniaxial strain, in which large surface areas are loaded and the measurements are restricted to a central region that is not influenced by lateral boundaries, is discussed. Measuring techniques are covered and instruments are discussed

  6. Preliminary Studies Of A Phase Modulation Technique For Measuring Chromaticity

    International Nuclear Information System (INIS)

    Tan, C.-Y.

    2006-01-01

    The classical method for measuring chromaticity is to slowly modulate the RF frequency and then measure the betatron tune excursion. The technique that is discussed in this paper instead modulates the phase of the RF and then the chromaticity is obtained by phase demodulating the betatron tune. This technique requires knowledge of the betatron frequency in real time in order for the phase to be demodulated. Fortunately, the Tevatron has a tune tracker based on the phase locked loop principle which fits this requirement. A preliminary study with this technique has showed that it is a promising method for doing continuous chromaticity measurement and raises the possibility of doing successful chromaticity feedback with it

  7. Wholefield displacement measurements using speckle image processing techniques for crash tests

    Science.gov (United States)

    Sriram, P.; Hanagud, S.; Ranson, W. F.

    The digital correlation scheme of Peters et al. (1983) was extended to measure out-of-plane deformations, using a white light projection speckle technique. A simple ray optic theory and the digital correlation scheme are outlined. The technique was applied successfully to measure out-of-plane displacements of initially flat rotorcraft structures (an acrylic circular plate and a steel cantilever beam), using a low cost video camera and a desktop computer. The technique can be extended to measurements of three-dimensional deformations and dynamic deformations.

  8. A Space Experiment to Measure the Atomic Oxygen Erosion of Polymers and Demonstrate a Technique to Identify Sources of Silicone Contamination

    Science.gov (United States)

    Banks, Bruce A.; deGroh, Kim K.; Baney-Barton, Elyse; Sechkar, Edward A.; Hunt, Patricia K.; Willoughby, Alan; Bemer, Meagan; Hope, Stephanie; Koo, Julie; Kaminski, Carolyn; hide

    1999-01-01

    A low Earth orbital space experiment entitled, "Polymers Erosion And Contamination Experiment", (PEACE) has been designed as a Get-Away Special (GAS Can) experiment to be accommodated as a Shuttle in-bay environmental exposure experiment. The first objective is to measure the atomic oxygen erosion yields of approximately 40 different polymeric materials by mass loss and erosion measurements using atomic force microscopy. The second objective is to evaluate the capability of identifying sources of silicone contamination through the use of a pin-hole contamination camera which utilizes environmental atomic oxygen to produce a contaminant source image on an optical substrate.

  9. A survey on multiproperty measurement techniques of solid materials

    International Nuclear Information System (INIS)

    Matsumoto, Tsuyoshi

    1989-01-01

    The term 'multiproperty measurement' has not as yet been widely used. It is defined as the simultaneous (or continuous) measurement of several properties of material using one sample and one set of equipment. It is highly advantageous to measure several properties of a sample simultaneously. Various aspects of the nature of a substance can be clarified by evaluating its nature in terms of many properties. In particular, advanced techniques for measuring thermal properties of material are needed in the fields of atomic energy industry, aerospace industry, energy industry, electronics industry and academic community. Conventional thermal property measurement techniques which can be applied to multiproperty measurement or minute test sample measurement are outlined focusing on measurement of the thermal conductivity (axial flow method, radial flow method, plate method, unsteady state heating coil method, direct current heating method), specific heat (adiabatic method, drop calorimetry, differential scanning calorimetry, AC calorimetric method, pulse heating method, and laser heating method), thermal diffusivity (laser-flash method), and emissivity (separated black body method, incorporated black body method). (N,K.)

  10. Intercomparison test of various aerosol measurement techniques

    International Nuclear Information System (INIS)

    Cherdron, W.; Hassa, C.; Jordan, S.

    1984-01-01

    At the suggestion of the CONT group (Containment Loading and Response), which is a subgroup of the Safety Working Group of the Fast Reactor Coordinating Committee, a group of experts undertook a comparison of the techniques of sodium aerosol measurement used in various laboratories in the EC. The following laboratories took part in the exercise: CEN-Mol (Belgium), CEA-Cadarache (France), CEA-Fontenay-aux-Roses (France), KfK-Karlsruhe (Federal Republic of Germany), ENEA-Bologna (Italy), and UKAEA-Winfrith (United Kingdom). The objective of the aerosol measurement workshop was to assess the applicability and reliability of specific aerosol measuring instruments. Measurements performed with equipment from the participating laboratories were evaluated using a standard procedure. This enabled an estimate of the accuracy of the experimental data to be provided for the verification of aerosol codes. Thus these results can be used as input for the physical modelling of aerosol behaviour, and the work reported here is a contribution to the definition of the radioactive source term for severe accidents in LMFBRs. The aerosol experts participating in the exercise agreed to concentrate on the techniques of measuring aerosol particle size distributions. The tests were performed at the FAUNA test facility using the aerosol loop. A sodium spray fire, which provides a continuous aerosol source of variable concentration, was produced under open-loop conditions in this facility. Although the primary objective of the workshop was to determine the particle size distributions of the aerosols, measurements of the sodium mass concentration were also made

  11. Double phi-Step theta-Scanning Technique for Spherical Near-Field Antenna Measurements

    DEFF Research Database (Denmark)

    Laitinen, Tommi

    2008-01-01

    Probe-corrected spherical near-field antenna measurements with an arbitrary probe set certain requirements on an applicable scanning technique. The computational complexity of the general high-order probe correction technique for an arbitrary probe, that is based on the Phi scanning, is O(N4...... a specific double Phi-step thetas scanning technique for spherical near-field antenna measurements. This technique not only constitutes an alternative spherical scanning technique, but it also enables formulating an associated probe correction technique for arbitrary probes with the computational complexity...

  12. Mississippi River streamflow measurement techniques at St. Louis, Missouri

    Science.gov (United States)

    Wastson, Chester C.; Holmes, Robert R.; Biedenham, David S.

    2013-01-01

    Streamflow measurement techniques of the Mississippi River at St. Louis have changed through time (1866–present). In addition to different methods used for discrete streamflow measurements, the density and range of discrete measurements used to define the rating curve (stage versus streamflow) have also changed. Several authors have utilized published water surface elevation (stage) and streamflow data to assess changes in the rating curve, which may be attributed to be caused by flood control and/or navigation structures. The purpose of this paper is to provide a thorough review of the available flow measurement data and techniques and to assess how a strict awareness of the limitations of the data may affect previous analyses. It is concluded that the pre-1930s discrete streamflow measurement data are not of sufficient accuracy to be compared with modern streamflow values in establishing long-term trends of river behavior.

  13. A direct-measurement technique for estimating discharge-chamber lifetime. [for ion thrusters

    Science.gov (United States)

    Beattie, J. R.; Garvin, H. L.

    1982-01-01

    The use of short-term measurement techniques for predicting the wearout of ion thrusters resulting from sputter-erosion damage is investigated. The laminar-thin-film technique is found to provide high precision erosion-rate data, although the erosion rates are generally substantially higher than those found during long-term erosion tests, so that the results must be interpreted in a relative sense. A technique for obtaining absolute measurements is developed using a masked-substrate arrangement. This new technique provides a means for estimating the lifetimes of critical discharge-chamber components based on direct measurements of sputter-erosion depths obtained during short-duration (approximately 1 hr) tests. Results obtained using the direct-measurement technique are shown to agree with sputter-erosion depths calculated for the plasma conditions of the test. The direct-measurement approach is found to be applicable to both mercury and argon discharge-plasma environments and will be useful for estimating the lifetimes of inert gas and extended performance mercury ion thrusters currently under development.

  14. Improved Tandem Measurement Techniques for Aerosol Particle Analysis

    Science.gov (United States)

    Rawat, Vivek Kumar

    Non-spherical, chemically inhomogeneous (complex) nanoparticles are encountered in a number of natural and engineered environments, including combustion systems (which produces highly non-spherical aggregates), reactors used in gas-phase materials synthesis of doped or multicomponent materials, and in ambient air. These nanoparticles are often highly diverse in size, composition and shape, and hence require determination of property distribution functions for accurate characterization. This thesis focuses on development of tandem mobility-mass measurement techniques coupled with appropriate data inversion routines to facilitate measurement of two dimensional size-mass distribution functions while correcting for the non-idealities of the instruments. Chapter 1 provides the detailed background and motivation for the studies performed in this thesis. In chapter 2, the development of an inversion routine is described which is employed to determine two dimensional size-mass distribution functions from Differential Mobility Analyzer-Aerosol Particle Mass analyzer tandem measurements. Chapter 3 demonstrates the application of the two dimensional distribution function to compute cumulative mass distribution function and also evaluates the validity of this technique by comparing the calculated total mass concentrations to measured values for a variety of aerosols. In Chapter 4, this tandem measurement technique with the inversion routine is employed to analyze colloidal suspensions. Chapter 5 focuses on application of a transverse modulation ion mobility spectrometer coupled with a mass spectrometer to study the effect of vapor dopants on the mobility shifts of sub 2 nm peptide ion clusters. These mobility shifts are then compared to models based on vapor uptake theories. Finally, in Chapter 6, a conclusion of all the studies performed in this thesis is provided and future avenues of research are discussed.

  15. Production of identified particles in p–Pb collisions at √sNN = 5.02 TeV measured with ALICE

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    Transverse momentum distributions of identified particles have been measured in several multiplicity classes in p-Pb collisions at sqrt(s_NN) = 5.02 TeV. This measurement can shed light on the understanding of possible collective effects in high multiplicity events. Furthermore p-Pb collisions bridge the charged multiplicity gap between pp and low multiplicity Pb–Pb collisions. Studying the particle production in this region can improve the understanding of the underlying production mechanisms. Particles are reconstructed with the central barrel detectors over a wide transverse momentum range (from 0 up to 15 GeV/c), exploiting different identification techniques.   Primary charged particles (pions, kaons, protons, antiprotons, deuterons and anti-deuterons) are identified by their specific energy loss (dE/dx) and time-of-flight. Weakly decaying particles are identified by their characteristic decay topology. Particle-production yields, spectral shapes and particle ratios have been m...

  16. Can 3D ultrasound identify trochlea dysplasia in newborns? Evaluation and applicability of a technique

    Energy Technology Data Exchange (ETDEWEB)

    Kohlhof, Hendrik, E-mail: Hendrik.Kohlhof@ukb.uni-bonn.de [Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Sigmund-Freud-Str. 25, 53127 Bonn (Germany); Heidt, Christoph, E-mail: Christoph.heidt@kispi.uzh.ch [Department of Orthopedic Surgery, University Children' s Hospital Zurich, Steinwiesstrasse 74, 8032 Switzerland (Switzerland); Bähler, Alexandrine, E-mail: Alexandrine.baehler@insel.ch [Department of Pediatric Radiology, University Children' s Hospital Berne, Freiburgstrasse 18, 3010 Berne (Switzerland); Kohl, Sandro, E-mail: sandro.kohl@insel.ch [Department of Orthopedic Surgery, University Hospital Berne, Freiburgstrasse 18, 3010 Berne (Switzerland); Gravius, Sascha, E-mail: sascha.gravius@ukb.uni-bonn.de [Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Sigmund-Freud-Str. 25, 53127 Bonn (Germany); Friedrich, Max J., E-mail: Max.Friedrich@ukb.uni-bonn.de [Clinic for Orthopedics and Trauma Surgery, University Hospital Bonn, Sigmund-Freud-Str. 25, 53127 Bonn (Germany); Ziebarth, Kai, E-mail: kai.ziebarth@insel.ch [Department of Orthopedic Surgery, University Hospital Berne, Freiburgstrasse 18, 3010 Berne (Switzerland); Stranzinger, Enno, E-mail: Enno.Stranzinger@insel.ch [Department of Pediatric Radiology, University Children' s Hospital Berne, Freiburgstrasse 18, 3010 Berne (Switzerland)

    2015-06-15

    Highlights: • We evaluated a possible screening method for trochlea dysplasia. • 3D ultrasound was used to perform the measurements on standardized axial planes. • The evaluation of the technique showed comparable results to other studies. • This technique may be used as a screening technique as it is quick and easy to perform. - Abstract: Femoro-patellar dysplasia is considered as a significant risk factor of patellar instability. Different studies suggest that the shape of the trochlea is already developed in early childhood. Therefore early identification of a dysplastic configuration might be relevant information for the treating physician. An easy applicable routine screening of the trochlea is yet not available. The purpose of this study was to establish and evaluate a screening method for femoro-patellar dysplasia using 3D ultrasound. From 2012 to 2013 we prospectively imaged 160 consecutive femoro-patellar joints in 80 newborns from the 36th to 61st gestational week that underwent a routine hip sonography (Graf). All ultrasounds were performed by a pediatric radiologist with only minimal additional time to the routine hip ultrasound. In 30° flexion of the knee, axial, coronal, and sagittal reformats were used to standardize a reconstructed axial plane through the femoral condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio of the trochlea and the shape of the patella (Wiberg Classification) were evaluated. In all examinations reconstruction of the standardized axial plane was achieved, the mean trochlea angle was 149.1° (SD 4.9°), the lateral-to-medial facet ratio of the trochlea ratio was 1.3 (SD 0.22), and a Wiberg type I patella was found in 95% of the newborn. No statistical difference was detected between boys and girls. Using standardized reconstructions of the axial plane allows measurements to be made with lower operator dependency and higher accuracy in a short time. Therefore 3D ultrasound is an easy

  17. Can 3D ultrasound identify trochlea dysplasia in newborns? Evaluation and applicability of a technique

    International Nuclear Information System (INIS)

    Kohlhof, Hendrik; Heidt, Christoph; Bähler, Alexandrine; Kohl, Sandro; Gravius, Sascha; Friedrich, Max J.; Ziebarth, Kai; Stranzinger, Enno

    2015-01-01

    Highlights: • We evaluated a possible screening method for trochlea dysplasia. • 3D ultrasound was used to perform the measurements on standardized axial planes. • The evaluation of the technique showed comparable results to other studies. • This technique may be used as a screening technique as it is quick and easy to perform. - Abstract: Femoro-patellar dysplasia is considered as a significant risk factor of patellar instability. Different studies suggest that the shape of the trochlea is already developed in early childhood. Therefore early identification of a dysplastic configuration might be relevant information for the treating physician. An easy applicable routine screening of the trochlea is yet not available. The purpose of this study was to establish and evaluate a screening method for femoro-patellar dysplasia using 3D ultrasound. From 2012 to 2013 we prospectively imaged 160 consecutive femoro-patellar joints in 80 newborns from the 36th to 61st gestational week that underwent a routine hip sonography (Graf). All ultrasounds were performed by a pediatric radiologist with only minimal additional time to the routine hip ultrasound. In 30° flexion of the knee, axial, coronal, and sagittal reformats were used to standardize a reconstructed axial plane through the femoral condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio of the trochlea and the shape of the patella (Wiberg Classification) were evaluated. In all examinations reconstruction of the standardized axial plane was achieved, the mean trochlea angle was 149.1° (SD 4.9°), the lateral-to-medial facet ratio of the trochlea ratio was 1.3 (SD 0.22), and a Wiberg type I patella was found in 95% of the newborn. No statistical difference was detected between boys and girls. Using standardized reconstructions of the axial plane allows measurements to be made with lower operator dependency and higher accuracy in a short time. Therefore 3D ultrasound is an easy

  18. Neutron measurement techniques for tokamak plasmas

    International Nuclear Information System (INIS)

    Jarvis, O.N.

    1994-01-01

    The present article reviews the neutron measurement techniques that are currently being applied to the study of tokamak plasmas. The range of neutron energies of primary interest is limited to narrow bands around 2.5 and 14 MeV, and the variety of measurements that can be made for plasma diagnostic purposes is also restricted. To characterize the plasma as a neutron source, it is necessary only to measure the total neutron emission, the relative neutron emissivity as a function of position throughout the plasma, and the energy spectra of the emitted neutrons. In principle, such measurements might be expected to be relatively easy. That this is not the case is, in part, attributable to practical problems of accessibility to a harsh environment but is mostly a consequence of the time-scale on which the measurements have to be made and of the wide range of neutron emission intensities that have to be covered: for tokamak studies, the time-scale is of the order of 1 to 100 ms and the neutron intensity ranges from 10 12 to 10 19 s -1 . (author)

  19. Review of geochemical measurement techniques for a nuclear waste repository in bedded salt

    International Nuclear Information System (INIS)

    Knauss, K.G.; Steinborn, T.L.

    1980-01-01

    A broad, general review is presented of geochemical measurement techniques that can provide data necessary for site selection and repository effectiveness assessment for a radioactive waste repository in bedded salt. The available measurement techniques are organized according to the parameter measured. The list of geochemical parameters include all those measurable geochemical properties of a sample whole values determine the geochemical characteristics or behavior of the system. For each technique, remarks are made pertaining to the operating principles of the measurement instrument and the purpose for which the technique is used. Attention is drawn to areas where further research and development are needed

  20. Protocol of measurement techniques - Project colored solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Chambrier, E. De; Roecker, Ch.; Scartezzini, J.-L.

    2004-08-15

    This illustrated annual report for the Swiss Federal Office of Energy (SFOE) takes a look at work done at the Swiss Federal Institute of Technology in Lausanne, Switzerland, on multi-layer, thin-film interference coatings for solar collector glazing. The correct combinations of refractive indices and film thickness are discussed. The authors state that corresponding multi-layered thin film stacks will have to be realised experimentally in a controlled and reproducible way. New thin film materials are to be tailored to exhibit optimised optical and ageing properties. The development of these coatings is to be based on various measurement techniques, such as spectro-photometry, measurements of total power throughput by means of a solar simulator, spectroscopic ellipsometry, scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The paper provides many examples of typical data and explains which film properties can be inferred from each method and thus describes both the function and purpose of the different measurement techniques.

  1. Measurement of particle velocity using a mutual inductance technique

    International Nuclear Information System (INIS)

    Kerr, Stephen; Kirkpatrick, Douglas; Garden, Steven

    2004-01-01

    Preliminary work on the development of a novel method for the measurement of particle velocity is described. The technique relies on measurement of the mutual inductance between two coaxial coils, one stationary and the other perturbed by the shock wave. The moving coil is the gauge and is deposited on thin film. The method was developed to assist in the study of particle velocities in large samples of porous media surrounding an explosive charge. The technique does not require measurements to be taken in a region of uniform magnetic field and therefore dispenses with the need for Helmholtz coils, the size and cost of which can become prohibitive for large experiments. This has the added advantage of allowing measurements to be taken at points widely dispersed through a sample with relative ease. Measurements of particle velocity in porous media have been compared with those from co-located conventional electromagnetic particle velocity gauges with reasonable agreement

  2. Measurements techniques for transportation noise

    International Nuclear Information System (INIS)

    Brambilla, G.

    2001-01-01

    The noise from transport systems (roads, railways and aircraft) are increasing more and more both in space and in time and, therefore, they are still the major factor responsible for environmental noise pollution. The population exposed to transport noise is also increasing, and the corresponding health effects on people (i.e. annoyance and sleep disturbance) become more severe. Due to this current situation international and national legislation has been issued and implemented to reduce the harmful effects of such noise. This paper describes the techniques prescribed by recent Italian legislation to measure road, railway and aircraft noise. (author)

  3. Identifying an outcome measure to assess the impact of Mobility Dogs.

    Science.gov (United States)

    Mudge, Suzie; Rewi, Dallas; Channon, Alexis

    2017-01-01

    Mobility Dogs® trains dogs to work with people with physical disabilities to increase independence, confidence, self-esteem and participation. Mobility Dogs® seeks to critically evaluate and improve its services as it grows. This study aimed to identify and implement a standardised outcome measure into practice at Mobility Dogs®. Based on the Consolidated Framework for Implementation Research and guided by a steering group of key stakeholders, a three-phase approach was developed to identify and assess an outcome measure. The steering group highlighted the organisation's specific needs, selected participation as the assessment domain and identified core utility requirements of the measure. A comprehensive review of evidence was undertaken to identify and rank potential measures according to the specified needs. Of the seven participation outcome measures that met inclusion criteria, the three highest ranked measures were critically evaluated by the steering group to determine suitability against the organisation's needs. The Impact on Participation and Autonomy (IPA) was selected for implementation into practice at Mobility Dogs®. Use of the IPA is an important first step for Mobility Dogs® to test the benefits of trained service dogs. This process could be replicated by other service dog organisations to identify outcome measures to assess their own services. Implications for Rehabilitation Service dogs (such as Mobility Dogs® in New Zealand) assist people living with physical impairments by performing tasks, however there is limited evidence on outcomes. The process for selecting an appropriate outcome measure for Mobility Dogs® involving partnership between Mobility Dogs® personnel and academics was an effective way to steer the project by determining important properties of the measure, before a search of the literature was undertaken. While the IPA was selected as the most appropriate outcome measure for use at Mobility Dogs®, it was the process that

  4. Measuring the corrosion rate of steel in concrete – effect of measurement technique, polarisation time and current

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica

    2012-01-01

    , are in some studies considered the main reasons for the variations. This paper presents an experimental study on the quantitative effect of polarisation time and current on the measured polarisation resistance – and thus the corrosion current density – of passively and actively corroding steel. Two...... electrochemical techniques often used in instruments for on-site corrosion rate measurements are investigated. On passively corroding reinforcement the measured polarisation resistance was for both techniques found to be highly affected by the polarisation time and current and no plateaus at either short or long...... rate for actively corroding steel. For both techniques guidelines for polarisation times and currents are given for (on-site) non-destructive corrosion rate measurements on reinforcement steel in concrete....

  5. Review of geotechnical measurement techniques for a nuclear waste repository in bedded salt

    International Nuclear Information System (INIS)

    1979-12-01

    This report presents a description of geotechnical measurement techniques that can provide the data necessary for safe development - i.e., location, design, construction, operation, decommissioning and abandonment - of a radioactive waste repository in bedded salt. Geotechnical data obtained by a diversity of measurement techniques are required during all phases of respository evolution. The techniques discussed in this report are grouped in the following categories: geologic, geophysical and geodetic; rock mechanics; hydrologic, hydrogeologic and water quality; and thermal. The major contribution of the report is the presentation of extensive tables that provide a review of available measurement techniques for each of these categories. The techniques are also discussed in the text to the extent necessary to describe the measurements and associated instruments, and to evaluate the applicability or limitations of the method. More detailed discussions of thermal phenomena, creep laws and geophysical methods are contained in the appendices; references to detailed explanations of measurement techniques and instrumentation are inluded throughout the report

  6. Review of geotechnical measurement techniques for a nuclear waste repository in bedded salt

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This report presents a description of geotechnical measurement techniques that can provide the data necessary for safe development - i.e., location, design, construction, operation, decommissioning and abandonment - of a radioactive waste repository in bedded salt. Geotechnical data obtained by a diversity of measurement techniques are required during all phases of respository evolution. The techniques discussed in this report are grouped in the following categories: geologic, geophysical and geodetic; rock mechanics; hydrologic, hydrogeologic and water quality; and thermal. The major contribution of the report is the presentation of extensive tables that provide a review of available measurement techniques for each of these categories. The techniques are also discussed in the text to the extent necessary to describe the measurements and associated instruments, and to evaluate the applicability or limitations of the method. More detailed discussions of thermal phenomena, creep laws and geophysical methods are contained in the appendices; references to detailed explanations of measurement techniques and instrumentation are inluded throughout the report.

  7. Objective techniques for psychological assessment, phase 2. [techniques for measuring human performance during space flight stress

    Science.gov (United States)

    Wortz, E. C.; Saur, A. J.; Nowlis, D. P.; Kendall, M. P.

    1974-01-01

    Results are presented of an initial experiment in a research program designed to develop objective techniques for psychological assessment of individuals and groups participating in long-duration space flights. Specifically examined is the rationale for utilizing measures of attention as an objective assessment technique. Subjects participating in the experiment performed various tasks (eg, playing matrix games which appeared on a display screen along with auditory stimuli). The psychophysiological reactions of the subjects were measured and are given. Previous research of various performance and psychophysiological methods of measuring attention is also discussed. The experiment design (independent and dependent variables) and apparatus (computers and display devices) are described and shown. Conclusions and recommendations are presented.

  8. Stopped-flow technique for transit time measurement in a gas jet

    International Nuclear Information System (INIS)

    Rengan, K.; Lin, J.; Lim, T.; Meyer, R.A.; Harrell, J.

    1985-01-01

    A 'stopped-flow' technique for the measurement of transit time of reaction products in a gas jet is described. The method involved establishing the gas flow through the jet system when the reactor is operating steadily and allowing the pressure to reach equilibrium values. The gas flow is stopped by means of electrically operated valves. The transit-time measurement is achieved by opening the valves and initiating the multiscanning of total activity simultaneously. The value obtained agrees well with the transit time measured by pulsing the reactor. The 'stopped-flow' technique allows on-line measurement of transit time in any gas jet system where the physical transportation time is the major component of the transit time. This technique is especially useful for systems installed in reactors which do not have pulsing capability. (orig.)

  9. Establishment of Measurement Techniques for Sliding Bubble on a Horizontal Tube

    International Nuclear Information System (INIS)

    Kim, Yu-Na Kim; Park, Goon-Cherl; Cho, Hyoung-Kyu

    2015-01-01

    The mechanistic wall boiling model includes many parameters relevant with bubble behaviors, such as the bubble departure diameter, bubble lift-off diameter, bubble waiting time, etc. Although there have been a large number of studies investigating bubble behavior, the subjects of observation are almost bubbles on a plane or vertical tube. Since the bubble motion is highly influenced by the directions of gravitational force and the heating surfaces, it is expected that the bubble behavior on a horizontal tube is largely different from those on the other geometry. The heat exchanger of APR+ has horizontal U-tube configuration installed in a water pool, of which diameter is 50mm. The study aims to establish measurement techniques for sliding bubbles on a horizontal tube. The measurement parameters include the diameter, interface area, volume, and velocity of the bubble. Additionally, in order to analyze the force acting on the bubble, liquid velocity measurement method was proposed. This paper presents the procedure of the measurement; the phase separation technique, 3-D reconstruction technique, and velocity measurement techniques. For visualization of the sliding bubble behavior, bubble and liquid velocity measurement methods were established which use two high speed cameras and a continuous LASER for the PTV and PIV. Three steps for the bubble shape and velocity measurement (the phase separation, 3-D reconstruction, and velocity calculation), were successfully set up and verified. A PIV technique which uses two different time duration for two regions where the velocity difference is huge was proposed and tested. Using these methods, various information regarding a sliding bubble can be obtained such as bubble and liquid velocities, shape, volume, surface area etc

  10. An Indentation Technique for Nanoscale Dynamic Viscoelastic Measurements at Elevated Temperature

    Science.gov (United States)

    Ye, Jiping

    2012-08-01

    Determination of nano/micro-scale viscoelasticity is very important to understand the local rheological behavior and degradation phenomena of multifunctional polymer blend materials. This article reviews research results concerning the development of indentation techniques for making nanoscale dynamic viscoelastic measurements at elevated temperature. In the last decade, we have achieved breakthroughs in noise floor reduction in air and thermal load drift/noise reduction at high temperature before taking on the challenge of nanoscale viscoelastic measurements. A high-temperature indentation technique has been developed that facilitates viscoelastic measurements up to 200 °C in air and 500 °C in a vacuum. During the last year, two viscoelastic measurement methods have been developed by making a breakthrough in suppressing the contact area change at high temperature. One is a sharp-pointed time-dependent nanoindentation technique for microscale application and the other is a spherical time-dependent nanoindentation technique for nanoscale application. In the near future, we expect to lower the thermal load drift and load noise floor even more substantially.

  11. Uncertainty analysis technique for OMEGA Dante measurements

    International Nuclear Information System (INIS)

    May, M. J.; Widmann, K.; Sorce, C.; Park, H.-S.; Schneider, M.

    2010-01-01

    The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

  12. Uncertainty Analysis Technique for OMEGA Dante Measurements

    International Nuclear Information System (INIS)

    May, M.J.; Widmann, K.; Sorce, C.; Park, H.; Schneider, M.

    2010-01-01

    The Dante is an 18 channel X-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g. hohlraums, etc.) at X-ray energies between 50 eV to 10 keV. It is a main diagnostics installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the X-ray diodes, filters and mirrors and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte-Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

  13. Dose measurement techniques for high-energy photon and electron radiation

    International Nuclear Information System (INIS)

    Hohlfeld, K.; Roos, M.

    1992-08-01

    By law the Federal Institute of Physics and Technology (PTB) has been assigned the tasks of representing, preserving and passing on dose units. The analogous continuation of these tasks consists in improving, at the user level, dosimetry techniques in radiation therapy for the benefit of patients. The PTB had an essential share in working out the scientific foundations of dosimetry for high-energy radiation, and the corresponding DIN standards were established with the PTB playing a prominent part. The seminar aimed at presenting the measuring techniques fixed in the new DIN standard 6800 part 2 'Dose measurement techniques according to the probe method - ionization dosimetry', to discuss their physical background and practical implications resulting from them. (orig.) [de

  14. Measurements of He II Thermal Counterflow Using PIV Technique

    International Nuclear Information System (INIS)

    Zhang, T.; Van Sciver, S.W.

    2004-01-01

    Our previous experiments on the measurements of He II thermal counterflow using Particle Image Velocimetry (PIV) have shown that there exists a substantial discrepancy between the measured and theoretical values of normal fluid velocity. It was assumed that this is due to the slip velocity between tracer particles and liquid helium. In the present work, tracer particles with a much smaller mean diameter and a more uniform size distribution were selected in order to reduce the effect of slip velocity, and an improved two phase fluidized bed technique was used to introduce the particles into liquid helium. The normal fluid velocity of thermal counterflow was then measured using the PIV technique at various heat fluxes and bath temperatures. The experimental results, however, still show the existence of discrepancy between PIV measured particle velocities and the theoretical normal fluid velocity. A preliminary explanation of these results is given based on an interaction of tracer particles with the superfluid component in the He II

  15. Measuring Industry Coagglomeration and Identifying the Driving Forces

    DEFF Research Database (Denmark)

    Howard, Emma; Newman, Carol; Tarp, Finn

    2015-01-01

    Understanding industry agglomeration and its driving forces is critical for the formulation of industrial policy in developing countries. Crucial to this process is the definition and measurement of agglomeration. We construct a new coagglomeration index based purely on the location of firms. We...... underlying stories at work. We conclude that in conducting analyses of this kind giving consideration to the source of agglomeration economies, employees or entrepreneurs, and finding an appropriate measure for agglomeration, are both crucial to the process of identifying agglomerative forces....

  16. Photogrammetry: applications of a three-dimensional remote measurement technique

    International Nuclear Information System (INIS)

    Peak, K.

    1988-01-01

    Photogrammetry is defined as the precise art of abstracting measurements from photographic images. Used for many years as a means to produce the world's maps, it has, in recent years, been applied in many engineering environments. The nuclear industry has, in particular, benefitted from the close range applications of photogrammetry. This paper sets out to describe the techniques involved, from the site photography through to the analytical data extraction. It will include a number of examples of where photogrammetry has been used in the nuclear industry as a remote measurement technique, from simple monitoring exercises to the compilation of complex three-dimensional as-built computer models. (author)

  17. Applications Of Measurement Techniques To Develop Small-Diameter, Undersea Fiber Optic Cables

    Science.gov (United States)

    Kamikawa, Neil T.; Nakagawa, Arthur T.

    1984-12-01

    Attenuation, strain, and optical time domain reflectometer (OTDR) measurement techniques were applied successfully in the development of a minimum-diameter, electro-optic sea floor cable. Temperature and pressure models for excess attenuation in polymer coated, graded-index fibers were investigated analytically and experimentally using these techniques in the laboratory. The results were used to select a suitable fiber for the cable. Measurements also were performed on these cables during predeployment and sea-trial testing to verify laboratory results. Application of the measurement techniques and results are summarized in this paper.

  18. Impedance measurement of irradiated potatoes: a method to identify radiation processing

    International Nuclear Information System (INIS)

    Mastro, N.L. del; Villavicencio, A.L.C.H.

    1992-01-01

    The potato is firmly established in many parts of the world as a major staple food. Then, radiation processing of potato is approved in many countries for sprouting inhibition and extension of shelf life in a dose range from about 0.01 to 0.15 kGy of 60 Co. The use of electrical conductance methods for the detection of Salmonella, some virus or the action of herbicides on plant has been reported and differences have been observed between instruments in respect of the magnitude of conductance change or rates of change in conductance response. A reliable technique to identify potatoes or other food products has not been established so far, though several methods have been reported. Electrical impedance might thus serve for characterization of unirradiated and irradiated tissues and cells. In this work, potato tubers from an European variety, named Bintje, grown in Sao Paulo State were employed. Potatoes were punctured with steel electrodes and impedance measured at different frequencies (1 k Hz-100 k Hz) by passing 3-5 m A alternating current through it. The impedance ratio of 50 k Hz/5 k Hz calculated from ten replicate samples decreases with the increment of the dose when doses of O 0.75 and 0.15 kGy from a Gamma Cell 220 were utilized. The impedance measurement were slightly affected by the place of puncture. (author)

  19. Auto-correlation based intelligent technique for complex waveform presentation and measurement

    International Nuclear Information System (INIS)

    Rana, K P S; Singh, R; Sayann, K S

    2009-01-01

    Waveform acquisition and presentation forms the heart of many measurement systems. Particularly, data acquisition and presentation of repeating complex signals like sine sweep and frequency-modulated signals introduces the challenge of waveform time period estimation and live waveform presentation. This paper presents an intelligent technique, for waveform period estimation of both the complex and simple waveforms, based on the normalized auto-correlation method. The proposed technique is demonstrated using LabVIEW based intensive simulations on several simple and complex waveforms. Implementation of the technique is successfully demonstrated using LabVIEW based virtual instrumentation. Sine sweep vibration waveforms are successfully presented and measured for electrodynamic shaker system generated vibrations. The proposed method is also suitable for digital storage oscilloscope (DSO) triggering, for complex signals acquisition and presentation. This intelligence can be embodied into the DSO, making it an intelligent measurement system, catering wide varieties of the waveforms. The proposed technique, simulation results, robustness study and implementation results are presented in this paper.

  20. Concept, characteristics, and applications of important electrical measuring techniques

    International Nuclear Information System (INIS)

    Amberg, C.; Czaika, N.; Andreae, G.

    1978-01-01

    In the field of electrical measuring techniques the investigations were concentrated on the transducers. We investigated the time-temperature behaviour of the following transducers: The weldable, fully encapsulated high temperature strain gauges, inductance and transformer displacement transducers, and weldable capacitive strain transducers with distance sensor. A literatur-review showing the state of techniques reference the influence of nuclear radiation was put together. (orig./HP) [de

  1. Advanced spherical near-field antenna measurement techniques

    DEFF Research Database (Denmark)

    Nielsen, Jeppe Majlund; Pivnenko, Sergey; Breinbjerg, Olav

    2011-01-01

    The DTU-ESA facility has since the 1980es provided highly accurate antenna radiation pattern measurements and gain calibration by use of the probe corrected spherical nearfield technique, both for ESA (the European Space Agency) and other customers and continues to do so. Recent years activities...... and research carried out at the facility are presented in the article. Since 2004 several antenna test facility comparison campaigns were carried out between a number of European antenna measurement facilities. The first campaigns laid the foundation for the later comparisons in providing experience...... in the period 2005–2006 following a series of investigatory measurements and facility updates during 2003–2005. Antenna diagnostics by a SWE-to-PWE transformation presents a case where highly accurate antenna measurements and a plane wave back-projection enable antenna diagnostics by examination...

  2. System reliability analysis using dominant failure modes identified by selective searching technique

    International Nuclear Information System (INIS)

    Kim, Dong-Seok; Ok, Seung-Yong; Song, Junho; Koh, Hyun-Moo

    2013-01-01

    The failure of a redundant structural system is often described by innumerable system failure modes such as combinations or sequences of local failures. An efficient approach is proposed to identify dominant failure modes in the space of random variables, and then perform system reliability analysis to compute the system failure probability. To identify dominant failure modes in the decreasing order of their contributions to the system failure probability, a new simulation-based selective searching technique is developed using a genetic algorithm. The system failure probability is computed by a multi-scale matrix-based system reliability (MSR) method. Lower-scale MSR analyses evaluate the probabilities of the identified failure modes and their statistical dependence. A higher-scale MSR analysis evaluates the system failure probability based on the results of the lower-scale analyses. Three illustrative examples demonstrate the efficiency and accuracy of the approach through comparison with existing methods and Monte Carlo simulations. The results show that the proposed method skillfully identifies the dominant failure modes, including those neglected by existing approaches. The multi-scale MSR method accurately evaluates the system failure probability with statistical dependence fully considered. The decoupling between the failure mode identification and the system reliability evaluation allows for effective applications to larger structural systems

  3. Evaluation of turbulence measurement techniques from a single Doppler lidar

    Directory of Open Access Journals (Sweden)

    T. A. Bonin

    2017-08-01

    Full Text Available Measurements of turbulence are essential to understand and quantify the transport and dispersal of heat, moisture, momentum, and trace gases within the planetary boundary layer (PBL. Through the years, various techniques to measure turbulence using Doppler lidar observations have been proposed. However, the accuracy of these measurements has rarely been validated against trusted in situ instrumentation. Herein, data from the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA are used to verify Doppler lidar turbulence profiles through comparison with sonic anemometer measurements. For 17 days at the end of the experiment, a single scanning Doppler lidar continuously cycled through different turbulence measurement strategies: velocity–azimuth display (VAD, six-beam scans, and range–height indicators (RHIs with a vertical stare.Measurements of turbulence kinetic energy (TKE, turbulence intensity, and stress velocity from these techniques are compared with sonic anemometer measurements at six heights on a 300 m tower. The six-beam technique is found to generally measure turbulence kinetic energy and turbulence intensity the most accurately at all heights (r2  ≈  0.78, showing little bias in its observations (slope of  ≈  0. 95. Turbulence measurements from the velocity–azimuth display method tended to be biased low near the surface, as large eddies were not captured by the scan. None of the methods evaluated were able to consistently accurately measure the shear velocity (r2 =  0.15–0.17. Each of the scanning strategies assessed had its own strengths and limitations that need to be considered when selecting the method used in future experiments.

  4. Noncontact sheet resistance measurement technique for wafer inspection

    Science.gov (United States)

    Kempa, Krzysztof; Rommel, J. Martin; Litovsky, Roman; Becla, Peter; Lojek, Bohumil; Bryson, Frank; Blake, Julian

    1995-12-01

    A new technique, MICROTHERM, has been developed for noncontact sheet resistance measurements of semiconductor wafers. It is based on the application of microwave energy to the wafer, and simultaneous detection of the infrared radiation resulting from ohmic heating. The pattern of the emitted radiation corresponds to the sheet resistance distribution across the wafer. This method is nondestructive, noncontact, and allows for measurements of very small areas (several square microns) of the wafer.

  5. A novel experimental technique of nuclear lifetime measurements

    International Nuclear Information System (INIS)

    Yuminov, O.A.; D'Arrigo, A.; Giardina, G.; Taccone, A.; Vannini, G.; Moroni, A.; Ricci, R.A.; Vannucci, L.

    1995-01-01

    In the present paper a new experimental method to measure nuclear reaction time in the 10 -15 -10 -10 s region is presented. Measurements of the lifetimes of low-lying and long-lived states of 19 F and 20 Ne decaying via α-channel were carried out with the aim of checking the feasibility of the method. The results obtained in this way are compared with the lifetimes known from different techniques. ((orig.))

  6. Validation of a technique of measurement in vivo of 131I in thyroids

    International Nuclear Information System (INIS)

    Villella, A.M.; Puerta Yepes, N.; Gossio, S.; Papadopulos, S.

    2010-01-01

    The Total Body Counter (TBC) Laboratory of the Nuclear Regulatory Authority, following the institutional initiative of quality assurance in its measurement techniques, has been involved in an accreditation process based on the ISO/IEC 17205:2005 norm. In vivo measurement of 131 I in thyroid has been selected as the first technique in this process, and it is described in this paper. The TBC Laboratory uses for this technique a gamma spectrometry system with a NaI(Tl) detector, calibrated with a neck simulator of the IRD and a certified plane source of 131 I with thyroid form. It has been carried out a validation plan that has permitted the characterization of the 131 I measurement technique, and its uncertainty evaluation. Measurement parameters that affect the uncertainty are discussed and recommendations for the technique optimization are proposed. (authors) [es

  7. A new bridge technique for neutron tomography and diffraction measurements

    International Nuclear Information System (INIS)

    Burca, G.; James, J.A.; Kockelmann, W.; Fitzpatrick, M.E.; Zhang, S.Y.; Hovind, J.; Langh, R. van

    2011-01-01

    An attractive feature of neutron techniques is the ability to identify hidden materials and structures inside engineering components and objects of art and archaeology. Bearing this in mind we are investigating a new technique, 'Tomography Driven Diffraction' (TDD), that exploits tomography data to guide diffraction experiments on samples with complex structures and shapes. The technique can be used utilising combinations of individual tomography and diffraction instruments, such as NEUTRA (PSI, CH) and ENGIN-X (ISIS, UK), but is also suitable for new combined imaging and diffraction instruments such as the JEEP synchrotron engineering instrument (DIAMOND, UK) and the proposed IMAT neutron imaging and diffraction instrument (ISIS, UK).

  8. Silt fences: An economical technique for measuring hillslope soil erosion

    Science.gov (United States)

    Peter R. Robichaud; Robert E. Brown

    2002-01-01

    Measuring hillslope erosion has historically been a costly, time-consuming practice. An easy to install low-cost technique using silt fences (geotextile fabric) and tipping bucket rain gauges to measure onsite hillslope erosion was developed and tested. Equipment requirements, installation procedures, statistical design, and analysis methods for measuring hillslope...

  9. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  10. Handbook of microwave component measurements with advanced VNA techniques

    CERN Document Server

    Dunsmore, Joel P

    2012-01-01

    This book provides state-of-the-art coverage for making measurements on RF and Microwave Components, both active and passive. A perfect reference for R&D and Test Engineers, with topics ranging from the best practices for basic measurements, to an in-depth analysis of errors, correction methods, and uncertainty analysis, this book provides everything you need to understand microwave measurements. With primary focus on active and passive measurements using a Vector Network Analyzer, these techniques and analysis are equally applicable to measurements made with Spectrum Analyzers or Noise Figure

  11. An improved visualization-based force-measurement technique for short-duration hypersonic facilities

    Energy Technology Data Exchange (ETDEWEB)

    Laurence, Stuart J.; Karl, Sebastian [Institute of Aerodynamics and Flow Technology, Spacecraft Section, German Aerospace Center (DLR), Goettingen (Germany)

    2010-06-15

    This article is concerned with describing and exploring the limitations of an improved version of a recently proposed visualization-based technique for the measurement of forces and moments in short-duration hypersonic wind tunnels. The technique is based on tracking the motion of a free-flying body over a sequence of high-speed visualizations; while this idea is not new in itself, the use of high-speed digital cinematography combined with a highly accurate least-squares tracking algorithm allows improved results over what have been previously possible with such techniques. The technique precision is estimated through the analysis of artificially constructed and experimental test images, and the resulting error in acceleration measurements is characterized. For wind-tunnel scale models, position measurements to within a few microns are shown to be readily attainable. Image data from two previous experimental studies in the T5 hypervelocity shock tunnel are then reanalyzed with the improved technique: the uncertainty in the mean drag acceleration is shown to be reduced to the order of the flow unsteadiness, 2-3%, and time-resolved acceleration measurements are also shown to be possible. The response time of the technique for the configurations studied is estimated to be {proportional_to}0.5 ms. Comparisons with computations using the DLR TAU code also yield agreement to within the overall experimental uncertainty. Measurement of the pitching moment for blunt geometries still appears challenging, however. (orig.)

  12. Techniques and methodologies to identify potential generated industries of NORM in Angola Republic and evaluate its impacts

    International Nuclear Information System (INIS)

    Diogo, José Manuel Sucumula

    2017-01-01

    Numerous steps have been taken worldwide to identify and quantify the radiological risks associated with the mining of ores containing Naturally Occurrence Radioactive Material (NORM), often resulting in unnecessary exposures to individuals and high environmental damage, with devastating consequences for the health of workers and damage to the economy of many countries due to a lack of regulations or inadequate regulations. For these and other reasons, the objective of this work was to identify industrial potential generating NORM in the Republic of Angola and to estimate its radiological environmental impacts. To achieve this objective, we studied the theoretical aspects, identified the main internationally recognized industrial companies that as generate by NORM. The Brazilian experience in the regulatory aspect was observed in the evaluation criteria to classify industries that generate NORM, the methods of mining and its radiological environmental impacts, as well as the main techniques applied to evaluate the concentrations of radionuclides in a specific environmental matrix and/or a NORM sample. The study approach allowed the elaboration of a NORM map for the main provinces of Angola, establishing the evaluation criteria for implementing the Radiation Protection Plan in the extractive industry, establishing measures to control ionizing radiation in mining, identifying and quantifying radionuclides present in samples of lees oil. However, in order to assess adequately the radiological environmental impact of the NORM industry, it is not enough to identify them, it is important to know the origin, quantify the radioactive material released as liquid and gaseous effluents, identify the main routes of exposure and examine how this material spreads into the environment until it reaches man. (author)

  13. Measurement uncertainty analysis techniques applied to PV performance measurements

    International Nuclear Information System (INIS)

    Wells, C.

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis? It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the I interval about a measured value or an experiment's final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis? A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results

  14. Measurement uncertainty analysis techniques applied to PV performance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Wells, C.

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the I interval about a measured value or an experiment's final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.

  15. Measurement uncertainty analysis techniques applied to PV performance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Wells, C

    1992-10-01

    The purpose of this presentation is to provide a brief introduction to measurement uncertainty analysis, outline how it is done, and illustrate uncertainty analysis with examples drawn from the PV field, with particular emphasis toward its use in PV performance measurements. The uncertainty information we know and state concerning a PV performance measurement or a module test result determines, to a significant extent, the value and quality of that result. What is measurement uncertainty analysis? It is an outgrowth of what has commonly been called error analysis. But uncertainty analysis, a more recent development, gives greater insight into measurement processes and tests, experiments, or calibration results. Uncertainty analysis gives us an estimate of the I interval about a measured value or an experiment`s final result within which we believe the true value of that quantity will lie. Why should we take the time to perform an uncertainty analysis? A rigorous measurement uncertainty analysis: Increases the credibility and value of research results; allows comparisons of results from different labs; helps improve experiment design and identifies where changes are needed to achieve stated objectives (through use of the pre-test analysis); plays a significant role in validating measurements and experimental results, and in demonstrating (through the post-test analysis) that valid data have been acquired; reduces the risk of making erroneous decisions; demonstrates quality assurance and quality control measures have been accomplished; define Valid Data as data having known and documented paths of: Origin, including theory; measurements; traceability to measurement standards; computations; uncertainty analysis of results.

  16. Measurement of detector neutron energy response using time-of-flight techniques

    International Nuclear Information System (INIS)

    Janee, H.S.

    1973-09-01

    The feasibility of using time-of-flight techniques at the EG and G/AEC linear accelerator for measuring the neutron response of relatively sensitive detectors over the energy range 0.5 to 14 MeV has been demonstrated. The measurement technique is described in detail as are the results of neutron spectrum measurements from beryllium and uranium photoneutron targets. The sensitivity of a fluor photomultiplier LASL detector with a 2- by 1-inch NE-111 scintillator was determined with the two targets, and agreement in the region of overlap was very good. (U.S.)

  17. A TECHNIQUE OF MEASURING OF RESISTANCE OF A GROUNDING DEVICE

    Directory of Open Access Journals (Sweden)

    I.V. Nizhevskyi

    2016-06-01

    Full Text Available Introduction. Measurement of resistance of the grounding device (GD by means of a three-electrode system. This requires not only the right choice of installation locations of measuring electrodes, but also the determination of the point of zero potential. Implementation of these requirements quite time-consuming, and in some cases impossible. Aim. Develop a new technique for measuring the electrical resistance of the GD. Task. The method of measuring the resistance of the GD with the help of a three-electrode setup is necessary to exclude the determination of the point of zero potential. Method. Mathematical modeling and calculation engine. Results. A three-electrode system for measuring the resistance of grounding devices (GD for various purposes is considered. On the basis of Maxwell equations a theoretical substantiation of a new technique for measuring the resistance of any GD of any construction in random soil structure has been proposed. An equation system of the sixth order has been obtained, its solution makes it possible to measure its own mutual resistance in the three-electrode installation with sufficiently high accuracy. Peculiarities of drawing up a calculation scheme of substitution of a three-electrode installation with lumped parameters: self and mutual impedance. Use of the principle of reciprocity eliminates the need of finding a point of zero potential which is a rather difficult task. The technique allows to minimize the spacing of measuring electrodes outside the GD, which substantially reduces the length of wiring of the measurement circuit and increases the «signal-to-interference» ratio and also removes the restrictions on the development of the territory outside the GD being tested. Conclusion. The procedure allows to evaluate the self and mutual impedance grounding all the electrodes in a three-electrode measuring installation of the grounding resistance of the device without finding the point of zero potential.

  18. Measurements of diversity gain and radiation efficiency of the eleven antenna by using different measurement techniques

    DEFF Research Database (Denmark)

    Yang, Jian; Pivnenko, Sergey; Laitinen, Tommi

    2010-01-01

    This paper presents measurement results of diversity gain and radiation efficiency by using three different measurement techniques: reverberation chamber, spherical near-field anechoic chamber, and multi-probe anechoic chamber. The results are measured over a large 2–8 GHz bandwidth which...

  19. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  20. High precision speed measurement by using interferometric techniques

    International Nuclear Information System (INIS)

    Ávila, M A Rodríguez; Valiente, R Ochoa; Trujillo, L A García

    2015-01-01

    In this work we present the experimental realization of speed measurement by the use of a two wave interferometer and digital signal processing techniques. We built an automated Michelson interferometer and using an He-Ne laser and with the use of the Fast Fourier Transform (FFT) and computer algorithms we derived a method for finding the speed of displacement. We report uncertainties in the order of 2-3 μm/s. with the use of this procedure. This brings the potential of another physical variable measurement like distance or pressure by this indirect measurement method. This approach is compared with an ultrasonic Logger Pro ® speed measurement system, and the results are compared between systems

  1. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Science.gov (United States)

    Kazys, Rymantas; Sliteris, Reimondas; Rekuviene, Regina; Zukauskas, Egidijus; Mazeika, Liudas

    2015-01-01

    An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer) on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C) and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%). PMID:26262619

  2. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions.

    Science.gov (United States)

    Kazys, Rymantas; Sliteris, Reimondas; Rekuviene, Regina; Zukauskas, Egidijus; Mazeika, Liudas

    2015-08-07

    An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer) on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C) and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10(-3) g/cm(3) (1%).

  3. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Directory of Open Access Journals (Sweden)

    Rymantas Kazys

    2015-08-01

    Full Text Available An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%.

  4. A poloidal field measurement technique

    International Nuclear Information System (INIS)

    Jobes, F.C.

    1989-07-01

    The poloidal field of a tokamak can be determined by observing the light emitted by He + ions injected into the plasma by a perpendicular He 0 beam. These ions will orbit in small circles located where the neutral atom became ionized, and they will remain there for a few microseconds. During this time, some of these ions will also emit light at various spectral lines. The observed spectrum of any of these lines will have a peculiar and very wide shape, and it will be offset (Doppler shifted) with respect to the natural line location. The location and width of the spectral pattern provide independent information about the components of the poloidal field which are parallel and perpendicular to the beam velocity, and this information is local to the point where the light is emitted. For a horizontal beam, these components are b x and b y , respectively. The difference in Doppler shift between two measurement points above one another (at the top and bottom of the beam) is directly proportional to δb x , which in turn is proportional to the transform on that flux surface. Thus, this technique provides a means to measure directly local values of q(r). Simulation studies indicate that accurate measurements can be made in milliseconds. 6 refs., 8 figs

  5. New Technique of Direct Intra-abdominal Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Elena Risin

    2006-10-01

    Conclusion: Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients.

  6. Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques

    Directory of Open Access Journals (Sweden)

    S Timothy Chelliah

    2011-01-01

    Full Text Available Aims: To evaluate the accuracy of measurement of hepatic venous pressure gradient by catheter wedge as compared to balloon wedge (the gold standard. Materials and Methods: Forty-five patients having a clinical diagnosis of intrahepatic portal hypertension were subjected to the two different types of pressure measurements (catheter wedge and balloon wedge during transjugular liver biopsy under fluoroscopic guidance. Statistical Analysis: Spearman′s rank correlation coefficient, Bland-Altman plot for agreement, and single measure intraclass correlation were used for analysis of data. Results: There was a close correlation between the results obtained by both the techniques, with highly significant concordance (P < 0.0001. Hepatic venous pressure gradients as measured by the catheter wedge technique were either equal to or less than those obtained by the balloon wedge technique. Conclusions: The difference in hepatic venous pressure gradients measured by the two techniques is insignificant.

  7. Identifying sources of atmospheric fine particles in Havana City using Positive Matrix Factorization technique

    International Nuclear Information System (INIS)

    Pinnera, I.; Perez, G.; Ramos, M.; Guibert, R.; Aldape, F.; Flores M, J.; Martinez, M.; Molina, E.; Fernandez, A.

    2011-01-01

    In previous study a set of samples of fine and coarse airborne particulate matter collected in a urban area of Havana City were analyzed by Particle-Induced X-ray Emission (PIXE) technique. The concentrations of 14 elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Br and Pb) were consistently determined in both particle sizes. The analytical database provided by PIXE was statistically analyzed in order to determine the local pollution sources. The Positive Matrix Factorization (PMF) technique was applied to fine particle data in order to identify possible pollution sources. These sources were further verified by enrichment factor (EF) calculation. A general discussion about these results is presented in this work. (Author)

  8. Remote measurement of atmospheric pollutants with laser techniques

    Energy Technology Data Exchange (ETDEWEB)

    Corio, W; Querzola, B; Zanzottera, E

    1979-03-01

    Laser techniques for the remote sensing of atmospheric pollutants are reviewed, with attention given to lidars based on Rayleigh and Mie scattering, the Raman effect, or fluorescent scattering. Emphasis is placed on differential absorption lidars, which rely on Rayleigh or Mie scattering for measurements made in the IR or in the visible-UV range, respectively. A comprehensive air pollution monitoring program based on differential absorption lidars, together with systems using fluorescent backscattering and absorption measurements with topographic backscattering, is described.

  9. A review of hemorheology: Measuring techniques and recent advances

    Science.gov (United States)

    Sousa, Patrícia C.; Pinho, Fernando T.; Alves, Manuel A.; Oliveira, Mónica S. N.

    2016-02-01

    Significant progress has been made over the years on the topic of hemorheology, not only in terms of the development of more accurate and sophisticated techniques, but also in terms of understanding the phenomena associated with blood components, their interactions and impact upon blood properties. The rheological properties of blood are strongly dependent on the interactions and mechanical properties of red blood cells, and a variation of these properties can bring further insight into the human health state and can be an important parameter in clinical diagnosis. In this article, we provide both a reference for hemorheological research and a resource regarding the fundamental concepts in hemorheology. This review is aimed at those starting in the field of hemodynamics, where blood rheology plays a significant role, but also at those in search of the most up-to-date findings (both qualitative and quantitative) in hemorheological measurements and novel techniques used in this context, including technical advances under more extreme conditions such as in large amplitude oscillatory shear flow or under extensional flow, which impose large deformations comparable to those found in the microcirculatory system and in diseased vessels. Given the impressive rate of increase in the available knowledge on blood flow, this review is also intended to identify areas where current knowledge is still incomplete, and which have the potential for new, exciting and useful research. We also discuss the most important parameters that can lead to an alteration of blood rheology, and which as a consequence can have a significant impact on the normal physiological behavior of blood.

  10. Introduction to electronic relaxation in solids: mechanisms and measuring techniques

    International Nuclear Information System (INIS)

    Bonville, P.

    1983-01-01

    The fluctuations of electronic magnetic moments in solids may be investigated by several techniques, either electronic or nuclear. This paper is an introduction of the most frequently encountered paramagnetic relaxation mechanisms (phonons, conduction electrons, exchange or dipolar interactions) in condensed matter, and to the different techniques used for measuring relaxation frequencies: electronic paramagnetic resonance, nuclear magnetic resonance, Moessbauer spectroscopy, inelastic neutron scattering, measurement of longitudinal ac susceptibility and γ-γ perturbed angular correlations. We mainly focus our attention on individual ionic fluctuation spectra, the majority of the experimental work refered to concerning rare earth systems [fr

  11. Soil volumetric water content measurements using TDR technique

    Directory of Open Access Journals (Sweden)

    S. Vincenzi

    1996-06-01

    Full Text Available A physical model to measure some hydrological and thermal parameters in soils will to be set up. The vertical profiles of: volumetric water content, matric potential and temperature will be monitored in different soils. The volumetric soil water content is measured by means of the Time Domain Reflectometry (TDR technique. The result of a test to determine experimentally the reproducibility of the volumetric water content measurements is reported together with the methodology and the results of the analysis of the TDR wave forms. The analysis is based on the calculation of the travel time of the TDR signal in the wave guide embedded in the soil.

  12. An expert botanical feature extraction technique based on phenetic features for identifying plant species.

    Directory of Open Access Journals (Sweden)

    Hoshang Kolivand

    Full Text Available In this paper, we present a new method to recognise the leaf type and identify plant species using phenetic parts of the leaf; lobes, apex and base detection. Most of the research in this area focuses on the popular features such as the shape, colour, vein, and texture, which consumes large amounts of computational processing and are not efficient, especially in the Acer database with a high complexity structure of the leaves. This paper is focused on phenetic parts of the leaf which increases accuracy. Detecting the local maxima and local minima are done based on Centroid Contour Distance for Every Boundary Point, using north and south region to recognise the apex and base. Digital morphology is used to measure the leaf shape and the leaf margin. Centroid Contour Gradient is presented to extract the curvature of leaf apex and base. We analyse 32 leaf images of tropical plants and evaluated with two different datasets, Flavia, and Acer. The best accuracy obtained is 94.76% and 82.6% respectively. Experimental results show the effectiveness of the proposed technique without considering the commonly used features with high computational cost.

  13. An expert botanical feature extraction technique based on phenetic features for identifying plant species

    Science.gov (United States)

    Fern, Bong Mei; Rahim, Mohd Shafry Mohd; Sulong, Ghazali; Baker, Thar; Tully, David

    2018-01-01

    In this paper, we present a new method to recognise the leaf type and identify plant species using phenetic parts of the leaf; lobes, apex and base detection. Most of the research in this area focuses on the popular features such as the shape, colour, vein, and texture, which consumes large amounts of computational processing and are not efficient, especially in the Acer database with a high complexity structure of the leaves. This paper is focused on phenetic parts of the leaf which increases accuracy. Detecting the local maxima and local minima are done based on Centroid Contour Distance for Every Boundary Point, using north and south region to recognise the apex and base. Digital morphology is used to measure the leaf shape and the leaf margin. Centroid Contour Gradient is presented to extract the curvature of leaf apex and base. We analyse 32 leaf images of tropical plants and evaluated with two different datasets, Flavia, and Acer. The best accuracy obtained is 94.76% and 82.6% respectively. Experimental results show the effectiveness of the proposed technique without considering the commonly used features with high computational cost. PMID:29420568

  14. Applied measuring techniques for the investigation of time-dependent flow phenomena in centrifugal compressors

    International Nuclear Information System (INIS)

    Hass, U.; Haupt, U.; Jansen, M.; Kassens, K.; Knapp, P.; Rautenberg, M.

    1978-01-01

    During the past 10 years new measuring techniques have been developed for the experimental investigation of highly loaded centrifugal compressors. These measuring techniques take into account the time dependency of the fluctuating physical quantities such as pressure, temperature, and velocity. Some key points of these experimental techniques are shown and explained in this paper. An important basis for such measurements is the accurate dynamic calibration of the measuring apparatus. In addition, some problems involved analyzing measured signals are dealt with and pressure measurements and their interpretation are shown. Finally optical, acoustical and vibrational measuring procedures are described which are additionally used for the investigation of non-stationary flow phenomena. (orig.) [de

  15. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg [University Hospital Balgrist and University of Zurich, Radiology, Zuerich (Switzerland); Farshad, Mazda; Espinosa, Norman [University Hospital Balgrist and University of Zurich, Department of Orthopaedic Surgery, Zuerich (Switzerland); Resnick, Donald [University of California San Diego, Department of Radiology, San Diego, CA (United States)

    2013-09-15

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  16. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    International Nuclear Information System (INIS)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg; Farshad, Mazda; Espinosa, Norman; Resnick, Donald

    2013-01-01

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  17. Identifying plant cell-surface receptors: combining 'classical' techniques with novel methods.

    Science.gov (United States)

    Uebler, Susanne; Dresselhaus, Thomas

    2014-04-01

    Cell-cell communication during development and reproduction in plants depends largely on a few phytohormones and many diverse classes of polymorphic secreted peptides. The peptide ligands are bound at the cell surface of target cells by their membranous interaction partners representing, in most cases, either receptor-like kinases or ion channels. Although knowledge of both the extracellular ligand and its corresponding receptor(s) is necessary to describe the downstream signalling pathway(s), to date only a few ligand-receptor pairs have been identified. Several methods, such as affinity purification and yeast two-hybrid screens, have been used very successfully to elucidate interactions between soluble proteins, but most of these methods cannot be applied to membranous proteins. Experimental obstacles such as low concentration and poor solubility of membrane receptors, as well as instable transient interactions, often hamper the use of these 'classical' approaches. However, over the last few years, a lot of progress has been made to overcome these problems by combining classical techniques with new methodologies. In the present article, we review the most promising recent methods in identifying cell-surface receptor interactions, with an emphasis on success stories outside the field of plant research.

  18. Heterodyne technique for measuring the amplitude and phase transfer functions of an optical modulator

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2002-01-01

    In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From the measure...... the measurements we derive the small-signal alpha-parameter and the time-dependent chirp for different operation conditions.......In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From...

  19. International workshop on measuring techniques for liquid metal flows (MTLM). Abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Gerbeth, G; Eckert, S [eds.

    1999-11-01

    The international workshop on 'Measuring techniques in liquid metal flows' (MTLM workshop) was organised in frame of the Dresden 'Innovationskolleg Magnetofluiddynamik'. The subject of the MTLM workshop was limited to methods to determine physical flow quantities such as velocity, pressure, void fraction, inclusion properties, crystallisation fronts etc. The present proceedings contain abstracts and viewgraphs of the oral presentations. During the last decades numerical simulations have become an important tool in industry and research to study the structure of flows and the properties of heat and mass transfer. However, in case of liquid metal flows there exists a significant problem to validate the codes with experimental data due to the lack of available measuring techniques. Due to the material properties (opaque, hot, chemical aggressive) the measurement of flow quantities is much more delicate in liquid metals compared to ordinary water flows. The generalisation of results obtained by means of water models to real liquid metal flows has often to be considered as difficult due to the problems to meet the actual values of n0n-dimensional flow parameters (Re, Pr, Gr, Ha, etc.). Moreover, a strong need has to be noted to make measuring techniques available tomonitor and to control flow processes in real industrial facilities. The objectives of the MTLM workshop were to: Review of existing information on a available techniques and experiences about the use in liquid metal flows, initiate a discussion between developers and potential users with respect to the actual need of information about the flow structure as well as the capabilities of existing and developing measuring techniques. Explore opportunities for co-operative R and D projects to expedite new developments and results, to share expertise and resources. (orig.)

  20. International workshop on measuring techniques for liquid metal flows (MTLM). Abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Gerbeth, G.; Eckert, S. [eds.

    1999-11-01

    The international workshop on 'Measuring techniques in liquid metal flows' (MTLM workshop) was organised in frame of the Dresden 'Innovationskolleg Magnetofluiddynamik'. The subject of the MTLM workshop was limited to methods to determine physical flow quantities such as velocity, pressure, void fraction, inclusion properties, crystallisation fronts etc. The present proceedings contain abstracts and viewgraphs of the oral presentations. During the last decades numerical simulations have become an important tool in industry and research to study the structure of flows and the properties of heat and mass transfer. However, in case of liquid metal flows there exists a significant problem to validate the codes with experimental data due to the lack of available measuring techniques. Due to the material properties (opaque, hot, chemical aggressive) the measurement of flow quantities is much more delicate in liquid metals compared to ordinary water flows. The generalisation of results obtained by means of water models to real liquid metal flows has often to be considered as difficult due to the problems to meet the actual values of n0n-dimensional flow parameters (Re, Pr, Gr, Ha, etc.). Moreover, a strong need has to be noted to make measuring techniques available tomonitor and to control flow processes in real industrial facilities. The objectives of the MTLM workshop were to: Review of existing information on a available techniques and experiences about the use in liquid metal flows, initiate a discussion between developers and potential users with respect to the actual need of information about the flow structure as well as the capabilities of existing and developing measuring techniques. Explore opportunities for co-operative R and D projects to expedite new developments and results, to share expertise and resources. (orig.)

  1. Measurement Techniques for Radon in Mines, Dwellings and the Environment

    International Nuclear Information System (INIS)

    Snihs, J.O.

    1983-06-01

    Definitions and units appropriate for radon and radon daughters are given. The principle methods of detection are ionization chamber, scintillation technique, nuclear track detector, thermoluminescent discs and alpha spectrometry. The activity concentration is determined by grab sampling and subsequent measurement, frequent or continuous grab sampling and measurement and continuous sampling and long time integrated measurement. Sampling and measurement strategies for mines, dwellings and the environment are discussed. (author)

  2. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, R; Moreno, I; Araujo, C [Facultad de Fisica, Universidad Autonoma de Zacatecas, Calz. Solidaridad Esquina Paseo de la Bufa s/n, C. P. 98060, Zacatecas, Zac. (Mexico); Marin, E, E-mail: emarin63@yahoo.e, E-mail: emarinm@ipn.m [Centro de Investigacion en Ciencia Aplicada y TecnologIa Avanzada, Instituto Politecnico Nacional, LegarIa 694, Colonia Irrigacion, C. P. 11500, Mexico D. F. (Mexico)

    2010-06-09

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  3. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    International Nuclear Information System (INIS)

    Ivanov, R; Moreno, I; Araujo, C; Marin, E

    2010-01-01

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  4. Slow neutron mapping technique for level interface measurement

    Science.gov (United States)

    Zain, R. M.; Ithnin, H.; Razali, A. M.; Yusof, N. H. M.; Mustapha, I.; Yahya, R.; Othman, N.; Rahman, M. F. A.

    2017-01-01

    Modern industrial plant operations often require accurate level measurement of process liquids in production and storage vessels. A variety of advanced level indicators are commercially available to meet the demand, but these may not suit specific need of situations. The neutron backscatter technique is exceptionally useful for occasional and routine determination, particularly in situations such as pressure vessel with wall thickness up to 10 cm, toxic and corrosive chemical in sealed containers, liquid petroleum gas storage vessels. In level measurement, high energy neutrons from 241Am-Be radioactive source are beamed onto a vessel. Fast neutrons are slowed down mostly by collision with hydrogen atoms of material inside the vessel. Parts of thermal neutron are bounced back towards the source. By placing a thermal detector next to the source, these backscatter neutrons can be measured. The number of backscattered neutrons is directly proportional to the concentration of the hydrogen atoms in front of the neutron detector. As the source and detector moved by the matrix around the side of the vessel, interfaces can be determined as long as it involves a change in hydrogen atom concentration. This paper presents the slow neutron mapping technique to indicate level interface of a test vessel.

  5. High-resolution wave number spectrum using multi-point measurements in space – the Multi-point Signal Resonator (MSR technique

    Directory of Open Access Journals (Sweden)

    Y. Narita

    2011-02-01

    Full Text Available A new analysis method is presented that provides a high-resolution power spectrum in a broad wave number domain based on multi-point measurements. The analysis technique is referred to as the Multi-point Signal Resonator (MSR and it benefits from Capon's minimum variance method for obtaining the proper power spectral density of the signal as well as the MUSIC algorithm (Multiple Signal Classification for considerably reducing the noise part in the spectrum. The mathematical foundation of the analysis method is presented and it is applied to synthetic data as well as Cluster observations of the interplanetary magnetic field. Using the MSR technique for Cluster data we find a wave in the solar wind propagating parallel to the mean magnetic field with relatively small amplitude, which is not identified by the Capon spectrum. The Cluster data analysis shows the potential of the MSR technique for studying waves and turbulence using multi-point measurements.

  6. A cable-free impedance and gain measurement technique for electrically small antennas

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Zhang, Jiaying; Breinbjerg, Olav

    2010-01-01

    are represented in terms of spherical wave expansions (SWEs), and the propagation is accounted for by a transmission formula. In this paper the measurement results by the proposed technique will be presented for several AUTs, including a standard gain horn antenna, a monopole antenna, and an electrically small......Impedance and gain measurements for electrically small antennas represent a great challenge due to influences of the feeding cable. The leaking current along the cable and scattering effects are two main issues caused by the feed line. In this paper, a novel cable-free antenna impedance and gain...... measurement technique for electrically small antennas is proposed. The antenna properties are extracted by measuring the signal scattered by the antenna under test (AUT), when it is loaded with three known loads. The technique is based on a rigorous electromagnetic model where the probe and AUT...

  7. Gamma ray densitometry techniques for measuring of volume fractions

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques

    2015-01-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  8. Gamma ray densitometry techniques for measuring of volume fractions

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  9. Use of variance techniques to measure dry air-surface exchange rates

    Science.gov (United States)

    Wesely, M. L.

    1988-07-01

    The variances of fluctuations of scalar quantities can be measured and interpreted to yield indirect estimates of their vertical fluxes in the atmospheric surface layer. Strong correlations among scalar fluctuations indicate a similarity of transfer mechanisms, which is utilized in some of the variance techniques. The ratios of the standard deviations of two scalar quantities, for example, can be used to estimate the flux of one if the flux of the other is measured, without knowledge of atmospheric stability. This is akin to a modified Bowen ratio approach. Other methods such as the normalized standard-deviation technique and the correlation-coefficient technique can be utilized effectively if atmospheric stability is evaluated and certain semi-empirical functions are known. In these cases, iterative calculations involving measured variances of fluctuations of temperature and vertical wind velocity can be used in place of direct flux measurements. For a chemical sensor whose output is contaminated by non-atmospheric noise, covariances with fluctuations of scalar quantities measured with a very good signal-to-noise ratio can be used to extract the needed standard deviation. Field measurements have shown that many of these approaches are successful for gases such as ozone and sulfur dioxide, as well as for temperature and water vapor, and could be extended to other trace substances. In humid areas, it appears that water vapor fluctuations often have a higher degree of correlation to fluctuations of other trace gases than do temperature fluctuations; this makes water vapor a more reliable companion or “reference” scalar. These techniques provide some reliable research approaches but, for routine or operational measurement, they are limited by the need for fast-response sensors. Also, all variance approaches require some independent means to estimate the direction of the flux.

  10. Using text-mining techniques in electronic patient records to identify ADRs from medicine use.

    Science.gov (United States)

    Warrer, Pernille; Hansen, Ebba Holme; Juhl-Jensen, Lars; Aagaard, Lise

    2012-05-01

    This literature review included studies that use text-mining techniques in narrative documents stored in electronic patient records (EPRs) to investigate ADRs. We searched PubMed, Embase, Web of Science and International Pharmaceutical Abstracts without restrictions from origin until July 2011. We included empirically based studies on text mining of electronic patient records (EPRs) that focused on detecting ADRs, excluding those that investigated adverse events not related to medicine use. We extracted information on study populations, EPR data sources, frequencies and types of the identified ADRs, medicines associated with ADRs, text-mining algorithms used and their performance. Seven studies, all from the United States, were eligible for inclusion in the review. Studies were published from 2001, the majority between 2009 and 2010. Text-mining techniques varied over time from simple free text searching of outpatient visit notes and inpatient discharge summaries to more advanced techniques involving natural language processing (NLP) of inpatient discharge summaries. Performance appeared to increase with the use of NLP, although many ADRs were still missed. Due to differences in study design and populations, various types of ADRs were identified and thus we could not make comparisons across studies. The review underscores the feasibility and potential of text mining to investigate narrative documents in EPRs for ADRs. However, more empirical studies are needed to evaluate whether text mining of EPRs can be used systematically to collect new information about ADRs. © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.

  11. Description and Evaluation of a Measurement Technique for Assessment of Performing Gender

    Science.gov (United States)

    Harris, Kathleen Mullan; Halpern, Carolyn Tucker

    2016-01-01

    The influence of masculinity and femininity on behaviors and outcomes has been extensively studied in social science research using various measurement strategies. In the present paper, we describe and evaluate a measurement technique that uses existing survey items to capture the extent to which an individual behaves similarly to their same-gender peers. We use data from the first four waves of The National Longitudinal Study of Adolescent to Adult Health (Add Health), a nationally representative sample of adolescents (age 12–18) in the United States who were re-interviewed at ages 13–19, 18–26, and 24–32. We estimate split-half reliability and provide evidence that supports the validity of this measurement technique. We demonstrate that the resulting measure does not perform as a trait measure and is associated with involvement in violent fights, a pattern consistent with theory and empirical findings. This measurement technique represents a novel approach for gender researchers with the potential for expanding our current knowledge base. PMID:28630528

  12. Apportionment of urban aerosol sources in Cork (Ireland) by synergistic measurement techniques.

    Science.gov (United States)

    Dall'Osto, Manuel; Hellebust, Stig; Healy, Robert M; O'Connor, Ian P; Kourtchev, Ivan; Sodeau, John R; Ovadnevaite, Jurgita; Ceburnis, Darius; O'Dowd, Colin D; Wenger, John C

    2014-09-15

    The sources of ambient fine particulate matter (PM2.5) during wintertime at a background urban location in Cork city (Ireland) have been determined. Aerosol chemical analyses were performed by multiple techniques including on-line high resolution aerosol time-of-flight mass spectrometry (Aerodyne HR-ToF-AMS), on-line single particle aerosol time-of-flight mass spectrometry (TSI ATOFMS), on-line elemental carbon-organic carbon analysis (Sunset_EC-OC), and off-line gas chromatography/mass spectrometry and ion chromatography analysis of filter samples collected at 6-h resolution. Positive matrix factorization (PMF) has been carried out to better elucidate aerosol sources not clearly identified when analyzing results from individual aerosol techniques on their own. Two datasets have been considered: on-line measurements averaged over 2-h periods, and both on-line and off-line measurements averaged over 6-h periods. Five aerosol sources were identified by PMF in both datasets, with excellent agreement between the two solutions: (1) regional domestic solid fuel burning--"DSF_Regional," 24-27%; (2) local urban domestic solid fuel burning--"DSF_Urban," 22-23%; (3) road vehicle emissions--"Traffic," 15-20%; (4) secondary aerosols from regional anthropogenic sources--"SA_Regional" 9-13%; and (5) secondary aged/processed aerosols related to urban anthropogenic sources--"SA_Urban," 21-26%. The results indicate that, despite regulations for restricting the use of smoky fuels, solid fuel burning is the major source (46-50%) of PM2.5 in wintertime in Cork, and also likely other areas of Ireland. Whilst wood combustion is strongly associated with OC and EC, it was found that peat and coal combustion is linked mainly with OC and the aerosol from these latter sources appears to be more volatile than that produced by wood combustion. Ship emissions from the nearby port were found to be mixed with the SA_Regional factor. The PMF analysis allowed us to link the AMS cooking organic

  13. Helium-flow measurement using ultrasonic technique

    International Nuclear Information System (INIS)

    Sondericker, J.H.

    1983-01-01

    While designing cryogenic instrumentation for the Colliding Beam Accelerator (CBA) helium-distribution system it became clear that accurate measurement of mass flow of helium which varied in temperature from room to sub-cooled conditions would be difficult. Conventional venturi flow meters full scale differential pressure signal would decrease by more than an order of magnitude during cooldown causing unacceptable error at operating temperature. At sub-cooled temperatures, helium would be pumped around cooling loops by an efficient, low head pressure circulating compressor. Additional pressure drop meant more pump work was necessary to compress the fluid resulting in a higher outlet temperature. The ideal mass flowmeter for this application was one which did not add pressure drop to the system, functioned over the entire temperature range, has high resolution and delivers accurate mass flow measurement data. Ultrasonic flow measurement techniques used successfully by the process industry, seemed to meet all the necessary requirements. An extensive search for a supplier of such a device found that none of the commercial stock flowmeters were adaptable to cryogenic service so the development of the instrument was undertaken by the CBA Cryogenic Control and Instrumentation Engineering Group at BNL

  14. Development of a technique for mass spectrometric measurement of δ18O of aqueous sulphate

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2003-01-01

    Application of stable isotopes of hydrogen and oxygen as tracers in hydrology for studying the origin of water is well established. δ 18 O of water molecule itself is used for identifying the source of water whereas δ 18 O of dissolved oxy anions (such as carbonate, phosphate, sulphate, nitrate and silicate) present in the same water reveal their source of origin. δ 18 O of SO 4 finds applications in identifying the origin of sulfate i.e. marine, marine evaporite or non-marine in nature and as a geothermometer in determining subsurface temperature of geothermal waters. A vacuum line of glass was fabricated to measure δ 18 O of aqueous sulfate. This paper deals with the technique and results of a trial with NBS-127, Sea water barium sulfate

  15. Fluvial sediment transport: Analytical techniques for measuring sediment load

    International Nuclear Information System (INIS)

    2005-07-01

    Sediment transport data are often used for the evaluation of land surface erosion, reservoir sedimentation, ecological habitat quality and coastal sediment budgets. Sediment transport by rivers is usually considered to occur in two major ways: (1) in the flow as a suspended load and (2) along the bed as a bed load. This publication provides guidance on selected techniques for the measurement of particles moving in both modes in the fluvial environment. The relative importance of the transport mode is variable and depends on the hydraulic and sedimentary conditions. The potential user is directed in the selection of an appropriate technique through the presentation of operating principles, application guidelines and estimated costs. Techniques which require laboratory analysis are grab sample, pump sample, depth sample, point integrated and radioactive tracers. Techniques which will continuously record data are optical backscattering, nuclear transmission, single frequency acoustic and laser diffraction

  16. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

    Science.gov (United States)

    Al-Fakih, Ebrahim A; Abu Osman, Noor Azuan; Mahmad Adikan, Faisal Rafiq

    2016-07-20

    The distribution of interface stresses between the residual limb and prosthetic socket of a transtibial amputee has been considered as a direct indicator of the socket quality fit and comfort. Therefore, researchers have been very interested in quantifying these interface stresses in order to evaluate the extent of any potential damage caused by the socket to the residual limb tissues. During the past 50 years a variety of measurement techniques have been employed in an effort to identify sites of excessive stresses which may lead to skin breakdown, compare stress distributions in various socket designs, and evaluate interface cushioning and suspension systems, among others. The outcomes of such measurement techniques have contributed to improving the design and fitting of transtibial sockets. This article aims to review the operating principles, advantages, and disadvantages of conventional and emerging techniques used for interface stress measurements inside transtibial sockets. It also reviews and discusses the evolution of different socket concepts and interface stress investigations conducted in the past five decades, providing valuable insights into the latest trends in socket designs and the crucial considerations for effective stress measurement tools that lead to a functional prosthetic socket.

  17. A photoacoustic technique to measure the properties of single cells

    Science.gov (United States)

    Strohm, Eric M.; Berndl, Elizabeth S. L.; Kolios, Michael C.

    2013-03-01

    We demonstrate a new technique to non-invasively determine the diameter and sound speed of single cells using a combined ultrasonic and photoacoustic technique. Two cell lines, B16-F1 melanoma cells and MCF7 breast cancer cells were examined using this technique. Using a 200 MHz transducer, the ultrasound backscatter from a single cell in suspension was recorded. Immediately following, the cell was irradiated with a 532 nm laser and the resulting photoacoustic wave recorded by the same transducer. The melanoma cells contain optically absorbing melanin particles, which facilitated photoacoustic wave generation. MCF7 cells have negligible optical absorption at 532 nm; the cells were permeabilized and stained with trypan blue prior to measurements. The measured ultrasound and photoacoustic power spectra were compared to theoretical equations with the cell diameter and sound speed as variables (Anderson scattering model for ultrasound, and a thermoelastic expansion model for photoacoustics). The diameter and sound speed were extracted from the models where the spectral shape matched the measured signals. However the photoacoustic spectrum for the melanoma cell did not match theory, which is likely because melanin particles are located around the cytoplasm, and not within the nucleus. Therefore a photoacoustic finite element model of a cell was developed where the central region was not used to generate a photoacoustic wave. The resulting power spectrum was in better agreement with the measured signal than the thermoelastic expansion model. The MCF7 cell diameter obtained using the spectral matching method was 17.5 μm, similar to the optical measurement of 16 μm, while the melanoma cell diameter obtained was 22 μm, similar to the optical measurement of 21 μm. The sound speed measured from the MCF7 and melanoma cell was 1573 and 1560 m/s, respectively, which is within acceptable values that have been published in literature.

  18. Calibration technique for the neutron surface moisture measurement system

    International Nuclear Information System (INIS)

    Watson, W.T.; Shreve, D.C.

    1996-01-01

    A technique for calibrating the response of a surface neutron moisture measurement probe to material moisture concentration has been devised. Tests to ensure that the probe will function in the expected in-tank operating environment are also outlined

  19. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    International Nuclear Information System (INIS)

    Prasser, H.M.

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  20. Evaluation of Techniques to Detect Significant Network Performance Problems using End-to-End Active Network Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, R.Les; Logg, Connie; Chhaparia, Mahesh; /SLAC; Grigoriev, Maxim; /Fermilab; Haro, Felipe; /Chile U., Catolica; Nazir, Fawad; /NUST, Rawalpindi; Sandford, Mark

    2006-01-25

    End-to-End fault and performance problems detection in wide area production networks is becoming increasingly hard as the complexity of the paths, the diversity of the performance, and dependency on the network increase. Several monitoring infrastructures are built to monitor different network metrics and collect monitoring information from thousands of hosts around the globe. Typically there are hundreds to thousands of time-series plots of network metrics which need to be looked at to identify network performance problems or anomalous variations in the traffic. Furthermore, most commercial products rely on a comparison with user configured static thresholds and often require access to SNMP-MIB information, to which a typical end-user does not usually have access. In our paper we propose new techniques to detect network performance problems proactively in close to realtime and we do not rely on static thresholds and SNMP-MIB information. We describe and compare the use of several different algorithms that we have implemented to detect persistent network problems using anomalous variations analysis in real end-to-end Internet performance measurements. We also provide methods and/or guidance for how to set the user settable parameters. The measurements are based on active probes running on 40 production network paths with bottlenecks varying from 0.5Mbits/s to 1000Mbit/s. For well behaved data (no missed measurements and no very large outliers) with small seasonal changes most algorithms identify similar events. We compare the algorithms' robustness with respect to false positives and missed events especially when there are large seasonal effects in the data. Our proposed techniques cover a wide variety of network paths and traffic patterns. We also discuss the applicability of the algorithms in terms of their intuitiveness, their speed of execution as implemented, and areas of applicability. Our encouraging results compare and evaluate the accuracy of our

  1. 3D shape measurement of automotive glass by using a fringe reflection technique

    Science.gov (United States)

    Skydan, O. A.; Lalor, M. J.; Burton, D. R.

    2007-01-01

    In automotive and glass making industries, there is a need for accurately measuring the 3D shapes of reflective surfaces to speed up and ensure product development and manufacturing quality by using non-contact techniques. This paper describes a technique for the measurement of non-full-field reflective surfaces of automotive glass by using a fringe reflection technique. Physical properties of the measurement surfaces do not allow us to apply optical geometries used in existing techniques for surface measurement based upon direct fringe pattern illumination. However, this property of surface reflectivity can be used to implement similar ideas from existing techniques in a new improved method. In other words, the reflective surface can be used as a mirror to reflect illuminated fringe patterns onto a screen behind. It has been found that in the case of implementing the reflective fringe technique, the phase-shift distribution depends not only on the height of the object but also on the slope at each measurement point. This requires the solving of differential equations to find the surface slope and height distributions in the x and y directions and development of the additional height reconstruction algorithms. The main focus has been made on developing a mathematical model of the optical sub-system and discussing ways for its practical implementation including calibration procedures. A number of implemented image processing algorithms for system calibration and data analysis are discussed and two experimental results are given for automotive glass surfaces with different shapes and defects. The proposed technique showed the ability to provide accurate non-destructive measurement of 3D shapes of the reflective automotive glass surfaces and can be used as a key element for a glass shape quality control system on-line or in a laboratory environment.

  2. Description of measurement techniques for surface contaminations

    International Nuclear Information System (INIS)

    Bourrez, E.

    2001-01-01

    The needs of evaluation of the surface contamination are numerous in the processes of production and management of radioactive waste. The market of radiation protection materials proposes a lot of devices answering to the almost all these needs. These device have however their conditions and particular limits for use. To realize correct measurements it is use the device, the technique and the methods adapted to the need, by taking into account the optimization of economical aspect. (N.C.)

  3. Oscillation experiments on Cesar and Marius - Experimental devices and measurement techniques

    International Nuclear Information System (INIS)

    Brunet, Max; Guerange, Jacques; Morier, Francis; Tonolli, Jacky

    1969-02-01

    An original method of measurement of effective cross sections of fissile materials has been developed by the CEA: a central fuel element of a critical experimental reactor is replaced by a sample containing the material to be studied. The replacement technique is based on oscillating the fuel load of the central channel. Signals are measured which are proportional to reactivity variation and to neutron density disturbance at the vicinity of the central channel, these variation and disturbance being produced by the sample oscillation. Measurements have been performed on experimental reactors (Minerve in Fontenay-aux-Roses, and Cesar and Marius in Cadarache). The authors herein describe the experimental devices and measurement techniques implemented in Marius and Cesar. In a first part, they describe the experimental devices which have been used during the three measurement campaigns (between 1965 and 1967). They report the study of measurement accuracies, and of some problems related to the use of the local detector [fr

  4. Computer Aided Measurement Laser (CAML): technique to quantify post-mastectomy lymphoedema

    International Nuclear Information System (INIS)

    Trombetta, Chiara; Abundo, Paolo; Felici, Antonella; Ljoka, Concetta; Foti, Calogero; Cori, Sandro Di; Rosato, Nicola

    2012-01-01

    Lymphoedema can be a side effect of cancer treatment. Eventhough several methods for assessing lymphoedema are used in clinical practice, an objective quantification of lymphoedema has been problematic. The aim of the study was to determine the objectivity, reliability and repeatability of the computer aided measurement laser (CAML) technique. CAML technique is based on computer aided design (CAD) methods and requires an infrared laser scanner. Measurements are scanned and the information describing size and shape of the limb allows to design the model by using the CAD software. The objectivity and repeatability was established in the beginning using a phantom. Consequently a group of subjects presenting post-breast cancer lymphoedema was evaluated using as a control the contralateral limb. Results confirmed that in clinical settings CAML technique is easy to perform, rapid and provides meaningful data for assessing lymphoedema. Future research will include a comparison of upper limb CAML technique between healthy subjects and patients with known lymphoedema.

  5. Hybrid PIV-PTV technique for measuring blood flow in rat mesenteric vessels.

    Science.gov (United States)

    Ha, Hojin; Nam, Kweon-Ho; Lee, Sang Joon

    2012-11-01

    The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues. In this study, a new hybrid PIV-PTV technique was established by combining PTV and particle image velocimetry (PIV) techniques to resolve the drawbacks of the μ-PTV method in measuring blood flow in microvessels under in vivo conditions. Images of red blood cells (RBCs) and fluorescent particles in rat mesenteric vessels were obtained simultaneously. Temporal variations of the centerline blood velocity were monitored using a fast Fourier transform-based cross-correlation PIV method. The fluorescence particle images were analyzed using the μ-PTV technique to extract the spatial distribution of the velocity vectors. Data from the μ-PTV and PIV methods were combined to obtain a better estimate of the velocity profile in actual blood flow. This technique will be useful in investigating hemodynamics in microcirculation by measuring unsteady irregular blood flows more accurately. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Comparing and assessing different measurement techniques for mercury in coal systhesis gas

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, D.P.; Richardson, C.F. [Radian Corporation, Austin, TX (United States)

    1995-11-01

    Three mercury measurement techniques were performed on synthesis gas streams before and after an amine-based sulfur removal system. The syngas was sampled using (1) gas impingers containing a nitric acid-hydrogen peroxide solution, (2) coconut-based charcoal sorbent, and (3) an on-line atomic absorption spectrophotometer equipped with a gold amalgamation trap and cold vapor cell. Various impinger solutions were applied upstream of the gold amalgamation trap to remove hydrogen sulfide and isolate oxidized and elemental species of mercury. The results from these three techniques are compared to provide an assessment of these measurement techniques in reducing gas atmospheres.

  7. Spectroscopic technique for measuring atmospheric CO2

    International Nuclear Information System (INIS)

    Stokes, G.M.; Stokes, R.A.

    1979-01-01

    As part of a continuing effort to identify areas in which astronomical techniques and data may be profitably applied to atmospheric problems, both new and archival solar spectra have been collected to prepare for an analysis of their use for studying the changes of the atmospheric CO 2 burden. This analysis has resulted in the initiation of an observing program using the Fourier Transform Spectrometer (FTS) of the McMath Solar Telescope at Kitt Peak National Observatory (KPNO). This program is generating spectra, the quality of which should not only aid the archival CO 2 study but also lead to analyses of other trace gases

  8. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  9. Using text-mining techniques in electronic patient records to identify ADRs from medicine use

    DEFF Research Database (Denmark)

    Warrer, Pernille; Hansen, Ebba Holme; Jensen, Lars Juhl

    2012-01-01

    This literature review included studies that use text-mining techniques in narrative documents stored in electronic patient records (EPRs) to investigate ADRs. We searched PubMed, Embase, Web of Science and International Pharmaceutical Abstracts without restrictions from origin until July 2011. We...... included empirically based studies on text mining of electronic patient records (EPRs) that focused on detecting ADRs, excluding those that investigated adverse events not related to medicine use. We extracted information on study populations, EPR data sources, frequencies and types of the identified ADRs......, medicines associated with ADRs, text-mining algorithms used and their performance. Seven studies, all from the United States, were eligible for inclusion in the review. Studies were published from 2001, the majority between 2009 and 2010. Text-mining techniques varied over time from simple free text...

  10. Development of Uncertainty Quantification Method for MIR-PIV Measurement using BOS Technique

    International Nuclear Information System (INIS)

    Seong, Jee Hyun; Song, Min Seop; Kim, Eung Soo

    2014-01-01

    Matching Index of Refraction (MIR) is frequently used for obtaining high quality PIV measurement data. ven small distortion by unmatched refraction index of test section can result in uncertainty problems. In this context, it is desirable to construct new concept for checking errors of MIR and following uncertainty of PIV measurement. This paper proposes a couple of experimental concept and relative results. This study developed an MIR uncertainty quantification method for PIV measurement using SBOS technique. From the reference data of the BOS, the reliable SBOS experiment procedure was constructed. Then with the combination of SBOS technique with MIR-PIV technique, velocity vector and refraction displacement vector field was measured simultaneously. MIR errors are calculated through mathematical equation, in which PIV and SBOS data are put. These errors are also verified by another BOS experiment. Finally, with the applying of calculated MIR-PIV uncertainty, correct velocity vector field can be obtained regardless of MIR errors

  11. Natural stream flow-rates measurements by tracer techniques

    International Nuclear Information System (INIS)

    Cuellar Mansilla, J.

    1982-01-01

    This paper presents the study of the precision obtained measuring the natural stream flow rates by tracer techniques, especially when the system presents a great slope and a bed constituted by large and extended particle size. The experiences were realized in laboratory pilot channels with flow-rates between 15 and 130 [1/s]; and in natural streams with flow-rates from 1 to 25 m 3 /s. Tracer used were In-133m and Br-82 for laboratory and field measurements respectively. In both cases the tracer was injected as a pulse and its dilution measured collecting samples in the measured section, at constant flow-rates, of 5[1] in laboratory experiences and 60[1] of water in field experiences. Precisions obtained at a 95% confidence level were about 2% for laboratory and 3% for field. (I.V.)

  12. A confirmatory measurement technique for highly enriched uranium

    International Nuclear Information System (INIS)

    Sprinkle, J.K. Jr.

    1987-07-01

    This report describes a confirmatory measurement technique for measuring uranium items in their shipping containers. The measurement consists of a weight verification and the detection of three gamma rays. The weight can be determined very precisely, thus it severely constrains the options of the diverter who might want to imitate the gamma signal with a bogus item. The 185.7-keV gamma ray originates from 235 U, the 1001 keV originates from a daughter of 238 U, and the 2614 keV originates from a daughter of 232 U. These three gamma rays exhibit widely different attenuation properties, they correlate with enrichment and total uranium mass, and they rigorously discriminate against a likely diversion scenario (low-enriched uranium substitution). These four measured quantities, when combined, provide a signature that is very difficult to counterfeit

  13. Noble Gas Measurement and Analysis Technique for Monitoring Reprocessing Facilities

    International Nuclear Information System (INIS)

    William S. Charlton

    1999-01-01

    An environmental monitoring technique using analysis of stable noble gas isotopic ratios on-stack at a reprocessing facility was developed. This technique integrates existing technologies to strengthen safeguards at reprocessing facilities. The isotopic ratios are measured using a mass spectrometry system and are compared to a database of calculated isotopic ratios using a Bayesian data analysis method to determine specific fuel parameters (e.g., burnup, fuel type, fuel age, etc.). These inferred parameters can be used by investigators to verify operator declarations. A user-friendly software application (named NOVA) was developed for the application of this technique. NOVA included a Visual Basic user interface coupling a Bayesian data analysis procedure to a reactor physics database (calculated using the Monteburns 3.01 code system). The integrated system (mass spectrometry, reactor modeling, and data analysis) was validated using on-stack measurements during the reprocessing of target fuel from a U.S. production reactor and gas samples from the processing of EBR-II fast breeder reactor driver fuel. These measurements led to an inferred burnup that matched the declared burnup with sufficient accuracy and consistency for most safeguards applications. The NOVA code was also tested using numerous light water reactor measurements from the literature. NOVA was capable of accurately determining spent fuel type, burnup, and fuel age for these experimental results. Work should continue to demonstrate the robustness of this system for production, power, and research reactor fuels

  14. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    Energy Technology Data Exchange (ETDEWEB)

    Prasser, H.M. (ed.)

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  15. HIV-1 envelope sequence-based diversity measures for identifying recent infections.

    Directory of Open Access Journals (Sweden)

    Alexis Kafando

    Full Text Available Identifying recent HIV-1 infections is crucial for monitoring HIV-1 incidence and optimizing public health prevention efforts. To identify recent HIV-1 infections, we evaluated and compared the performance of 4 sequence-based diversity measures including percent diversity, percent complexity, Shannon entropy and number of haplotypes targeting 13 genetic segments within the env gene of HIV-1. A total of 597 diagnostic samples obtained in 2013 and 2015 from recently and chronically HIV-1 infected individuals were selected. From the selected samples, 249 (134 from recent versus 115 from chronic infections env coding regions, including V1-C5 of gp120 and the gp41 ectodomain of HIV-1, were successfully amplified and sequenced by next generation sequencing (NGS using the Illumina MiSeq platform. The ability of the four sequence-based diversity measures to correctly identify recent HIV infections was evaluated using the frequency distribution curves, median and interquartile range and area under the curve (AUC of the receiver operating characteristic (ROC. Comparing the median and interquartile range and evaluating the frequency distribution curves associated with the 4 sequence-based diversity measures, we observed that the percent diversity, number of haplotypes and Shannon entropy demonstrated significant potential to discriminate recent from chronic infections (p<0.0001. Using the AUC of ROC analysis, only the Shannon entropy measure within three HIV-1 env segments could accurately identify recent infections at a satisfactory level. The env segments were gp120 C2_1 (AUC = 0.806, gp120 C2_3 (AUC = 0.805 and gp120 V3 (AUC = 0.812. Our results clearly indicate that the Shannon entropy measure represents a useful tool for predicting HIV-1 infection recency.

  16. Effect of heterophoria measurement technique on the clinical accommodative convergence to accommodation ratio.

    Science.gov (United States)

    Escalante, Jaime Bernal; Rosenfield, Mark

    2006-05-01

    Measurement of the stimulus accommodative convergence to accommodation (AC/A) ratio is a standard procedure in clinical optometric practice. Typically, heterophoria is assessed at several accommodative stimulus levels, and the gradient of the vergence to accommodation function computed. A number of procedures are available for the subjective measurement of heterophoria, but it is unclear whether the use of different vergence measurement techniques will alter the obtained AC/A value. Accordingly, the current study compared AC/A ratios measured using 3 clinical subjective heterophoria tests, namely the von Graefe (VG), Maddox Rod (MR), and Modified Thorington (MT) procedures. The AC/A ratio was measured in 60 visually normal subjects between 20 and 25 years of age using each of the 3 procedures listed above. The accommodative stimulus was varied by the introduction of +/-1.00 diopter (D) spherical lenses over the distance refractive correction while subjects viewed a target at a viewing distance of 40 cm. To examine the repeatability of each procedure, the AC/A ratio was measured on 2 separate occasions for each measurement technique, with the 2 sessions being separated by at least 24 hours. Mean values of stimulus AC/A ratio measured using the VG, MR, and MT procedures were 3.47, 2.99, and 2.46Delta/D, respectively. These differences were significant (p=0.0001). In addition, the coefficient of repeatability for the 3 techniques was 2.22, 1.99, and 1.20 Delta/D, respectively. Ratios obtained using the Modified Thorington technique with +/-1.00 D lenses showed the best repeatability, whereas the poorest repeatability was found with the von Graefe technique when only +1.00 D lenses were used to vary the accommodative stimulus. Accordingly, we recommend that that Modified Thorington procedure with +/-1.00 D lenses be used to quantify heterophoria during clinical measurement of the stimulus AC/A ratio.

  17. Uncertainty Analysis for Oil-Film Interferometry Skin-Friction Measurement Techniques

    Science.gov (United States)

    Naughton, Jonathan W.; Brown, James L.; Merriam, Marshal (Technical Monitor)

    1996-01-01

    Over the past 20 years, the use of oil-film interferometry to measure the skin friction coefficient (C(sub f) = tau/q where tau is the surface shear stress and q is the dynamic pressure) has increased. Different forms of this oil-film technique with various levels of accuracy and ease of use have been successfully applied in a wide range of flows. The method's popularity is growing due to its relative ease of implementation and minimal intrusiveness as well as an increased demand for C(sub f) measurements. Nonetheless, the accuracy of these methods has not been rigorously addressed to date. Most researchers have simply shown that the skin-friction measurements made using these techniques compare favorably with other measurements and theory, most of which are only accurate to within 5-20%. The use of skin-friction data in the design of commercial aircraft, whose drag at cruise is 50% skin-friction drag, and in the validation of computational fluid dynamics programs warrants better uncertainty estimates. Additional information is contained in the original extended abstract.

  18. The study of transit time measurement for flow through the central and southern canals of MADA using I-131 radioisotope technique

    International Nuclear Information System (INIS)

    Roslan Mohd Ali; Md Shahid Ayub; Zainuddin Othman; Juhari Yusof; Mohd Asri Ramli; Eow Boon Tiak

    1996-01-01

    The measurement of breakthrough and transit time through the central and southern canals of Lembaga Kemajuan Pertanian Muda (MADA) by using radiotracer technique is discussed An estimated of 1700 cusec water was released from Pelubang regulator through central canal. The water is then distributed through several regulators down stream and finally ended through the SCD1 and SCD1a secondary canals. Radiotracer 1-131 with the activity of 250 mCi and 500 mCi were injected at several identified injection points by using glass breaker technique. The measurement of breakthrough and transit time were observed respectively at several measurement station. Results of the study indicated that the time travel from Pelubang regulator to SCD1a secondary canal would take about 3 days during normal operation. Detail of breakthrough and transit time at every regulators and other measurement stations were also presented

  19. Moisture measurements in iron ores, in freight cars, through nuclear techniques

    International Nuclear Information System (INIS)

    Castagnet, A.C.; Said, M.; Duarte, U.

    1975-01-01

    The possibility and the advantages of using a nuclear technique for measuring on the spot (in the freight cars) and the moisture content of iron ores are described. The measurements included the determination of the volumetric moisture content and the density. From this values, the moisture content in percentage by weight was calculated. Nuclear Chicago d/M Combination Density-Moisture Probe with a 5 mCi Ra/Be source, and a digital portable scaler, were used. The investigated techniques give good results when the measurements are made directly on the ore surface, and has economical advantages over the gravimetric method by sampling. The probable reasons for both, the aleatory scattering of points and the lack of linear correlation between the values of both methods, when the nuclear measurement is made across the car walls are analized

  20. Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

    International Nuclear Information System (INIS)

    Martens, Hans-Juergen von

    2010-01-01

    The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s 2 ). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

  1. Pressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model.

    Science.gov (United States)

    Chopra, Sascha Santosh; Wolf, Stefan; Rohde, Veit; Freimann, Florian Baptist

    2015-01-01

    Introduction. Intra-abdominal pressure (IAP) measurement is an indispensable tool for the diagnosis of abdominal hypertension. Different techniques have been described in the literature and applied in the clinical setting. Methods. A porcine model was created to simulate an abdominal compartment syndrome ranging from baseline IAP to 30 mmHg. Three different measurement techniques were applied, comprising telemetric piezoresistive probes at two different sites (epigastric and pelvic) for direct pressure measurement and intragastric and intravesical probes for indirect measurement. Results. The mean difference between the invasive IAP measurements using telemetric pressure probes and the IVP measurements was -0.58 mmHg. The bias between the invasive IAP measurements and the IGP measurements was 3.8 mmHg. Compared to the realistic results of the intraperitoneal and intravesical measurements, the intragastric data showed a strong tendency towards decreased values. The hydrostatic character of the IAP was eliminated at high-pressure levels. Conclusion. We conclude that intragastric pressure measurement is potentially hazardous and might lead to inaccurately low intra-abdominal pressure values. This may result in missed diagnosis of elevated abdominal pressure or even ACS. The intravesical measurements showed the most accurate values during baseline pressure and both high-pressure plateaus.

  2. The verification tests of residual radioactivity measurement and assessment techniques for buildings and soils

    International Nuclear Information System (INIS)

    Onozawa, T.; Ishikura, T.; Yoshimura, Yukio; Nakazawa, M.; Makino, S.; Urayama, K.; Kawasaki, S.

    1996-01-01

    According to the standard procedure for decommissioning a commercial nuclear power plant (CNPP) in Japan, controlled areas will be released for unrestricted use before the dismantling of a reactor building. If manual survey and sampling techniques were applied to measurement for unrestricted release on and in the extensive surface of the building, much time and much specialized labor would be required to assess the appropriateness of the releasing. Therefore the authors selected the following three techniques for demonstrating reliability and applicability of the techniques for CNPPs: (1) technique of assessing radioactive concentration distribution on the surface of buildings (ADB); (2) technique of assessing radioactive permeation distribution in the concrete structure of buildings (APB); (3) technique of assessing radioactive concentration distribution in soil (ADS). These tests include the techniques of measuring and assessing very low radioactive concentration distribution on the extensive surfaces of buildings and the soil surrounding of a plant with automatic devices. Technical investigation and preliminary study of the verification tests were started in 1990. In the study, preconditions were clarified for each technique and the performance requirements were set up. Moreover, simulation models have been constructed for several feasible measurement method to assess their performance in terms of both measurement test and simulation analysis. Fundamental tests have been under way using small-scale apparatuses since 1994

  3. Measurement and characterization techniques for thermoelectric materials

    Energy Technology Data Exchange (ETDEWEB)

    Tritt, T M

    1997-07-01

    Characterization of thermoelectric materials can pose many problems. A temperature difference can be established across these materials as an electrical current is passed due to the Peltier effect. The thermopower of these materials is quite large and thus large thermal voltages can contribute to many of the measurements necessary to investigate these materials. This paper will discuss the chracterization techniques necessary to investigate these materials and provide an overview of some of the potential systematic errors which can arise. It will also discuss some of the corrections one needs to consider. This should provide an introduction to the characterization and measurement of thermoelectric materials and provide references for a more in depth discussion of the concepts. It should also serve as an indication of the care that must be taken while working with thermoelectric materials.

  4. Using the ultrasound and instrumented indentation techniques to measure the elastic modulus of engineering materials

    International Nuclear Information System (INIS)

    Meza, J. M.; Franco, E. E.; Farias, M. C. M.; Buiochi, F.; Souza, R. M.; Cruz, J.

    2008-01-01

    Currently, the acoustic and nano indentation techniques are two of the most used techniques for materials elastic modulus measurement. In this article fundamental principles and limitations of both techniques are shown and discussed. Last advances in nano indentation technique are also reviewed. an experimental study in ceramic, metallic, composite and single crystals was also done. Results shown that ultrasonic technique is capable to provide results in agreement with those reported in literature. However, ultrasonic technique does not allow measuring the elastic modulus of some small samples and single crystals. On the other hand, the nano indentation technique estimates the elastic modulus values in reasonable agreement with those measured by acoustic methods, particularly in amorphous materials, while in some policristaline materials some deviation from expected values was obtained. (Author) 29 refs

  5. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    Science.gov (United States)

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual

  6. Higher order Cambell techniques for neutron flux measurement. Pt. 1

    International Nuclear Information System (INIS)

    Lux, I.; Baranyai, A.

    1982-01-01

    An exact mathematical description of arbitrary high order Campbell techniques for measuring particle fluxes is given. The nth order Campbell technique assumes the measurement of the moments of the outcoming voltage up to the nth one. A simple relation is derived among the various moments of the total measured voltage and of the detector signal caused by one incident particle. It is proven that in the monoparticle case combination of the measured moments up to the order n provides an expression proportional to the particle flux and to the nth moment of the detector signal. Generalization to several different particles is given and it is shown that if the flux of the particle causing the largest detector signal is measured with a relative error epsilon in the dc method and the error is due to the signals of other particles, then in the nth order campbelling the error will be of order epsilonsup(n). The effect of a random background on the measured voltage is also investigated and it is established that the nth order campbelling supresses the noise according to the nth power of the relative amplitude of the noise to the signal. The results concerning constant fluxes are generalized to time dependent particle fluxes and a method assuming a Fourier transform of the measured quantities is proposed for their determination. (orig.)

  7. Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

    International Nuclear Information System (INIS)

    Ravelo Arias, S. I.; Ramírez Muñoz, D.; Cardoso, S.; Ferreira, R.; Freitas, P.

    2015-01-01

    The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others

  8. Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ravelo Arias, S. I.; Ramírez Muñoz, D. [Department of Electronic Engineering, University of Valencia, Avda. de la Universitat, s/n, 46100-Burjassot (Spain); Cardoso, S. [INESC Microsystems and Nanotechnologies (INESC-MN) and Institute for Nanosciences and Nanotechnologies, R. Alves Redol 9, Lisbon 1000-029 (Portugal); Ferreira, R. [INL-International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, Braga 4715-31 (Portugal); Freitas, P. [INESC Microsystems and Nanotechnologies (INESC-MN) and Institute for Nanosciences and Nanotechnologies, R. Alves Redol 9, Lisbon 1000-029 (Portugal); INL-International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, Braga 4715-31 (Portugal)

    2015-06-15

    The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others.

  9. Techniques and instrumentation for the measurement of transient sound energy flux

    Science.gov (United States)

    Watkinson, P. S.; Fahy, F. J.

    1983-12-01

    The evaluation of sound intensity distributions, and sound powers, of essentially continuous sources such as automotive engines, electric motors, production line machinery, furnaces, earth moving machinery and various types of process plants were studied. Although such systems are important sources of community disturbance and, to a lesser extent, of industrial health hazard, the most serious sources of hearing hazard in industry are machines operating on an impact principle, such as drop forges, hammers and punches. Controlled experiments to identify major noise source regions and mechanisms are difficult because it is normally impossible to install them in quiet, anechoic environments. The potential for sound intensity measurement to provide a means of overcoming these difficulties has given promising results, indicating the possibility of separation of directly radiated and reverberant sound fields. However, because of the complexity of transient sound fields, a fundamental investigation is necessary to establish the practicability of intensity field decomposition, which is basic to source characterization techniques.

  10. Advanced intensity-modulation continuous-wave lidar techniques for ASCENDS CO2 column measurements

    Science.gov (United States)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. W.; Obland, Michael D.; Meadows, Byron

    2015-10-01

    Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

  11. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for ASCENDS O2 Column Measurements

    Science.gov (United States)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. Wallace; Obland, Michael D.; Meadows, Byron

    2015-01-01

    Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

  12. Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    England, Andrew; Niker, Amanda; Redmond, Claire

    2010-01-01

    Purpose: The aim of this project is to assess the variability of six CT measurement techniques for sizing abdominal aortic aneurysms (AAAs). Method: 37 CT scans with known AAAs were loaded on to a departmental picture archiving and communication system (PACS). A team of three observers, with experience in aortic CT measurements and the PACS performed a series of 2D and 3D measurements on the abdominal aorta. Each observer was asked to measure 3 quantities; anterior-posterior AAA diameter, maximum oblique AAA diameter, maximum aneurysm area using both 2D and 3D techniques. In order to test intra-observer variability each observer was asked to repeat their measurements. All measurements were taken using electronic callipers, under standardised viewing conditions using previously calibrated equipment. 3D measurements were conducted using a computer generated central luminal line (CLL). All measurements for this group were taken perpendicular to the CLL. Results: A total of 972 independent measurements were recorded by three observers. Mean intra-observer variability was lower for 2D diameter measurements (AP 1.3 ± 1.6 mm; 2D Oblique 1.2 ± 1.3 mm) and 2D areas (0.7 ± 1.3 cm 2 ) when compared to inter-observer variability (AP 1.7 ± 1.9 mm; Oblique 1.6 ± 1.7 mm; area 1.1 ± 1.5 cm 2 ). When comparing 2D with 3D measurements, differences were comparable except for 3D AP diameter and area which had lower inter-observer variability than their 2D counterparts (AP 2D 1.7 ± 1.9 mm, 3D 1.3 ± 1.3 mm; area 2D 1.1 ± 1.5 cm 2 , 3D 0.7 ± 0.7 cm 2 ). 3D area measurement was the only technique which had equal variability for intra- and inter-observer measurements. Overall observer variability for the study was good with 94-100% of all paired measurements within 5.00 mm/cm 2 or less. Using Pitman's test it can be confirmed that area measurements in the 3D plane have the least variability (r = 0.031) and 3D oblique measurements have the highest variability (r = 0

  13. Center edge angle measurement for hip preservation surgery: technique and caveats.

    Science.gov (United States)

    Anderson, Lucas A; Gililland, Jeremy; Pelt, Christopher; Linford, Samuel; Stoddard, Gregory J; Peters, Christopher L

    2011-01-01

    Anterior and lateral center edge angles have traditionally been used to determine acetabular coverage, and thereby strongly influence the decision to perform acetabular reorientation versus osteochondroplasty in patients with dysplasia and/or femoroacetabular impingement. We propose templating the center of the contained articular femoral head in aspherical hips to provide reliable assessment of acetabular coverage. Digital radiographs of 30 patients with various combinations of femoral and acetabular morphologies were evaluated using 2 methods to identify the anterior center edge angle and lateral center edge angle. The control method used an estimated femoral head center for angle apex. The study technique determined the center of the femoral head by templating the congruent aspect of the femoral head contained by the acetabulum while ignoring the increasing lateral and anterior radius associated with cam deformities. Four readers measured lateral center edge angles on anteroposterior radiographs and anterior center edge angles on false-profile radiographs. Two reads were performed by each reader using both the estimated and the templated methods for a total of 4 reads. Interobserver reliability using the proposed method compared to the standard was much improved for anterior center edge angles (intraclass correlation coefficient of 0.76 vs 0.55) as well as with lateral center edge angles (ICC of 0.80 vs 0.42). Decreased correlation was most commonly associated with abnormal sourcil morphology, posterior wall deficiency combined with calcified labra, and os acetabuli. Including the anterolateral cam deformity in identifying the center of the femoral head for measuring center edge angles leads to an underestimation of acetabular coverage, which may negatively affect hip preservation surgical decision making. Copyright 2011, SLACK Incorporated.

  14. Technique for the focal-length measurement of positive lenses using Fizeau interferometry

    International Nuclear Information System (INIS)

    Pavan Kumar, Yeddanapudi; Chatterjee, Sanjib

    2009-01-01

    We present what we believe is a new technique for the focal-length measurement of positive lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The image distance is measured interferometrically in terms of the radius of curvature of the image-forming wavefront emerging from the lens. The radii of curvature of the image-forming wavefronts corresponding to two different axial object positions of known separation are measured. The focal length of the lens is determined by solving the equations obtained using the Gaussian lens equation for the two object positions. Results obtained for a corrected doublet lens of a nominal focal length of 200.0 mm with a measurement uncertainty of ±2.5% is presented

  15. Simulation error propagation for a dynamic rod worth measurement technique

    International Nuclear Information System (INIS)

    Kastanya, D.F.; Turinsky, P.J.

    1996-01-01

    KRSKO nuclear station, subsequently adapted by Westinghouse, introduced the dynamic rod worth measurement (DRWM) technique for measuring pressurized water reactor rod worths. This technique has the potential for reduced test time and primary loop waste water versus alternatives. The measurement is performed starting from a slightly supercritical state with all rods out (ARO), driving a bank in at the maximum stepping rate, and recording the ex-core detectors responses and bank position as a function of time. The static bank worth is obtained by (1) using the ex-core detectors' responses to obtain the core average flux (2) using the core average flux in the inverse point-kinetics equations to obtain the dynamic bank worth (3) converting the dynamic bank worth to the static bank worth. In this data interpretation process, various calculated quantities obtained from a core simulator are utilized. This paper presents an analysis of the sensitivity to the impact of core simulator errors on the deduced static bank worth

  16. Reactivity change measurements on plutonium-uranium fuel elements in hector experimental techniques and results

    International Nuclear Information System (INIS)

    Tattersall, R.B.; Small, V.G.; MacBean, I.J.; Howe, W.D.

    1964-08-01

    The techniques used in making reactivity change measurements on HECTOR are described and discussed. Pile period measurements were used in the majority of oases, though the pile oscillator technique was used occasionally. These two methods are compared. Flux determinations were made in the vicinity of the fuel element samples using manganese foils, and the techniques used are described and an error assessment made. Results of both reactivity change and flux measurements on 1.2 in. diameter uranium and plutonium-uranium alloy fuel elements are presented, these measurements being carried out in a variety of graphite moderated lattices at temperatures up to 450 deg. C. (author)

  17. [Use of the critical incident technique in the development of a measurement tool for satisfaction in psychiatry].

    Science.gov (United States)

    Pourin, C; Daucourt, V; Barberger-Gateau, P

    2001-06-01

    Health care centers will have to set up a regular survey of their patients' satisfaction, in addition to the discharge questionnaire. Few instruments for measuring satisfaction are at present available. A working group associating 10 psychiatric hospitals in Aquitaine conducted a study on the specificity of this measure in psychiatry. To record the patient's perception on the stay in order to identify areas of satisfaction and dissatisfaction as perceived and reported by himself, using a qualitative approach. The critical incident technique was used in 3 volunteer hospitals, in patients hospitalised in psychiatric wards selected by their doctor. Interview using a semi-structured questionnaire were conducted by an investigator external to the departments. Data were analysed in a qualitative way. 32 interviews could be analysed, and 215 events were extracted. These events were classified in 12 themes. The events identified from these interviews have allowed identification of new areas of patient satisfaction, which could be used to build additional items centered on patients' preoccupations.

  18. Top-quark mass measurements: Alternative techniques (LHC + Tevatron)

    CERN Document Server

    Adomeit, Stefanie; The ATLAS collaboration

    2014-01-01

    Measurements of the top-quark mass employing alternative techniques are presented, performed by the D0 and CDF collaborations at the Tevatron as well as the ATLAS and CMS experiments at the LHC. The alternative methods presented include measurements using the lifetime of $B$-hadrons, the transverse momentum of charged leptons and the endpoints of kinematic distributions in top quark anti-quark pair ($t\\bar{t}$) final states. The extraction of the top-quark pole mass from the $t\\bar{t}$ production cross-section and the normalized differential $t\\bar{t}$ + 1-jet cross-section are discussed as well as the top-quark mass extraction using fixed-order QCD predictions at detector level. Finally, a measurement of the top-quark mass using events enhanced in single top t-channel production is presented.

  19. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 Measurements

    Science.gov (United States)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Liu, Z.; Kooi, S. A.; Fan, T. F.; Nehrir, A. R.; Meadows, B.; Browell, E. V.

    2016-12-01

    Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 MeasurementsJoel F. Campbell1, Bing Lin1, Michael D. Obland1, Zhaoyan Liu1, Susan Kooi2, Tai-Fang Fan2, Amin R. Nehrir1, Byron Meadows1, Edward V. Browell31NASA Langley Research Center, Hampton, VA 23681 2SSAI, NASA Langley Research Center, Hampton, VA 23681 3STARSS-II Affiliate, NASA Langley Research Center, Hampton, VA 23681 AbstractGlobal and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby minimizing bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new sub-meter hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. These techniques are used in a new data processing

  20. Identifying the sources of produced water in the oil field by isotopic techniques

    International Nuclear Information System (INIS)

    Nguyen Minh Quy; Hoang Long; Le Thi Thu Huong; Luong Van Huan; Vo Thi Tuong Hanh

    2014-01-01

    The objective of this study is to identify the sources of the formation water in the Southwest Su-Tu-Den (STD SW) basement reservoir. To achieve the objective, isotopic techniques along with geochemical analysis for chloride, bromide, strontium dissolved in the water were applied. The isotopic techniques used in this study were the determination of water stable isotopes signatures (δ 2 H and (δ 18 O) and of the 87 Sr/ 86 Sr ratio of strontium in rock cutting sample and that dissolved in the formation water. The obtained results showed that the stable isotopes compositions of water in the Lower Miocene was -3‰ and -23‰ for (δ 18 O and (δ 2 H, respectively indicating the primeval nature of seawater in the reservoir. Meanwhile, the isotopic composition of water in the basement was clustered in a range of alternated freshwater with (δ 18 O and (δ 2 H being -(3-4)‰ and -(54-60)‰, respectively). The strontium isotopes ratio for water in the Lower Miocene reservoir was lower compared to that for water in the basement confirming the different natures of the water in the two reservoirs. The obtained results are assured for the techniques applicability, and it is recommended that studies on identification of the flow-path of the formation water in the STD SW basement reservoir should be continued. (author)

  1. Color measurement of tea leaves at different drying periods using hyperspectral imaging technique.

    Science.gov (United States)

    Xie, Chuanqi; Li, Xiaoli; Shao, Yongni; He, Yong

    2014-01-01

    This study investigated the feasibility of using hyperspectral imaging technique for nondestructive measurement of color components (ΔL*, Δa* and Δb*) and classify tea leaves during different drying periods. Hyperspectral images of tea leaves at five drying periods were acquired in the spectral region of 380-1030 nm. The three color features were measured by the colorimeter. Different preprocessing algorithms were applied to select the best one in accordance with the prediction results of partial least squares regression (PLSR) models. Competitive adaptive reweighted sampling (CARS) and successive projections algorithm (SPA) were used to identify the effective wavelengths, respectively. Different models (least squares-support vector machine [LS-SVM], PLSR, principal components regression [PCR] and multiple linear regression [MLR]) were established to predict the three color components, respectively. SPA-LS-SVM model performed excellently with the correlation coefficient (rp) of 0.929 for ΔL*, 0.849 for Δa*and 0.917 for Δb*, respectively. LS-SVM model was built for the classification of different tea leaves. The correct classification rates (CCRs) ranged from 89.29% to 100% in the calibration set and from 71.43% to 100% in the prediction set, respectively. The total classification results were 96.43% in the calibration set and 85.71% in the prediction set. The result showed that hyperspectral imaging technique could be used as an objective and nondestructive method to determine color features and classify tea leaves at different drying periods.

  2. Color measurement of tea leaves at different drying periods using hyperspectral imaging technique.

    Directory of Open Access Journals (Sweden)

    Chuanqi Xie

    Full Text Available This study investigated the feasibility of using hyperspectral imaging technique for nondestructive measurement of color components (ΔL*, Δa* and Δb* and classify tea leaves during different drying periods. Hyperspectral images of tea leaves at five drying periods were acquired in the spectral region of 380-1030 nm. The three color features were measured by the colorimeter. Different preprocessing algorithms were applied to select the best one in accordance with the prediction results of partial least squares regression (PLSR models. Competitive adaptive reweighted sampling (CARS and successive projections algorithm (SPA were used to identify the effective wavelengths, respectively. Different models (least squares-support vector machine [LS-SVM], PLSR, principal components regression [PCR] and multiple linear regression [MLR] were established to predict the three color components, respectively. SPA-LS-SVM model performed excellently with the correlation coefficient (rp of 0.929 for ΔL*, 0.849 for Δa*and 0.917 for Δb*, respectively. LS-SVM model was built for the classification of different tea leaves. The correct classification rates (CCRs ranged from 89.29% to 100% in the calibration set and from 71.43% to 100% in the prediction set, respectively. The total classification results were 96.43% in the calibration set and 85.71% in the prediction set. The result showed that hyperspectral imaging technique could be used as an objective and nondestructive method to determine color features and classify tea leaves at different drying periods.

  3. Work of adhesion measurements by a periodic cracking technique

    International Nuclear Information System (INIS)

    Davutoglu, A.; Aksay, I.A.

    1981-01-01

    In a recent study, Chow et al. introduced a technique for determining the energy associated with interfacial separation of a two-layer composite which consisted of a polymeric substrate and a brittle film overcoat. The technique is based on a model which assumes a perfectly elastic composite. In the present study, it s shown that as long as only the film component of the composite is brittle, the technique is also applicable to the composites where the substrates may display plastic deformation prior to adhesive failure of the film. Strain measurements, instead of load, eliminate the difficulties introduced by the plastic behavior of the substrate. Experimental work was performed on systems containing brittle amorphous selenium films on aluminum and Mylar substrates. These systems with selenium films were of interest due to their usage in photoreceptor technology

  4. An efficient similarity measure technique for medical image registration

    Indian Academy of Sciences (India)

    In this paper, an efficient similarity measure technique is proposed for medical image registration. The proposed approach is based on the Gerschgorin circles theorem. In this approach, image registration is carried out by considering Gerschgorin bounds of a covariance matrix of two compared images with normalized ...

  5. Verification of long-term load measurement technique

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe

    storage and 3) data analysis technique to verify design load assumptions. The work is carried out under Contract no 019945 (SES6) "UPWIND" within the European Commission The interaction between the mechanical and electrical generator subsystems is described rudimentarily, based primarily on HAWC2...... simulations below stall of the mechanical system with simple generator and gearbox systems. The electrical system simulations were not carried out as intended in DOW[2], but indications of the conditions for establishing the interaction have been described by measurements and by argument, that this might have...

  6. Progress in automation, robotics and measuring techniques

    CERN Document Server

    Zieliński, Cezary; Kaliczyńska, Małgorzata

    2015-01-01

    This book presents recent progresses in control, automation, robotics, and measuring techniques. It includes contributions of top experts in the fields, focused on both theory and industrial practice. The particular chapters present a deep analysis of a specific technical problem which is in general followed by a numerical analysis and simulation, and results of an implementation for the solution of a real world problem. The presented theoretical results, practical solutions and guidelines will be useful for both researchers working in the area of engineering sciences and for practitioners solving industrial problems.    .

  7. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    Relations between radiation risks and radiation protection measuring techniques are considered as components of the radiation risk. The influence of the exposure risk on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Based upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high exposure risk. As a consequence the following recommendations are presented: occupationally exposed persons with small exposure risk should be monitored using only a long-term desimeter (for instance a thermoluminescence desimeter). In the case of internal exposure, the surface and air contamination levels should be controlled so strictly that routine measurements of internal contamination need not be performed

  8. A COMPARISON OF STELLAR ELEMENTAL ABUNDANCE TECHNIQUES AND MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Hinkel, Natalie R.; Young, Patrick A.; Pagano, Michael D.; Desch, Steven J.; Anbar, Ariel D. [School of Earth and Space Exploration, Arizona State University, Tempe, AZ 85287 (United States); Adibekyan, Vardan; Mena, Elisa Delgado; Sousa, Sergio G.; Santos, Nuno C. [Instituto de Astrofísica e Ciências do Espaço, Universidade do Porto, CAUP, Rua das Estrelas, 4150-762 Porto (Portugal); Blanco-Cuaresma, Sergi [Observatoire de Genève, Université de Genève, CH-1290 Versoix (Switzerland); Carlberg, Joleen K. [NASA Goddard Space Flight Center, Code 667, Greenbelt MD 20771 (United States); Liu, Fan [Research School of Astronomy and Astrophysics, Australian National University, Cotter Road, Weston Creek, ACT 2611 (Australia); Nordlander, Thomas; Korn, Andreas; Gruyters, Pieter; Heiter, Ulrike [Department of Physics and Astronomy, Uppsala University, Box 516, 75120 Uppsala (Sweden); Jofré, Paula [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Soubiran, Caroline, E-mail: natalie.hinkel@gmail.com [CNRS/Univ. Bordeaux, LAB, UMR 5804, F-33270, Floirac (France)

    2016-09-01

    Stellar elemental abundances are important for understanding the fundamental properties of a star or stellar group, such as age and evolutionary history, as well as the composition of an orbiting planet. However, as abundance measurement techniques have progressed, there has been little standardization between individual methods and their comparisons. As a result, different stellar abundance procedures determine measurements that vary beyond the quoted error for the same elements within the same stars. The purpose of this paper is to better understand the systematic variations between methods and offer recommendations for producing more accurate results in the future. We invited a number of participants from around the world (Australia, Portugal, Sweden, Switzerland, and the United States) to calculate 10 element abundances (C, O, Na, Mg, Al, Si, Fe, Ni, Ba, and Eu) using the same stellar spectra for four stars (HD 361, HD 10700, HD 121504, and HD 202206). Each group produced measurements for each star using (1) their own autonomous techniques, (2) standardized stellar parameters, (3) a standardized line list, and (4) both standardized parameters and a line list. We present the resulting stellar parameters, absolute abundances, and a metric of data similarity that quantifies the homogeneity of the data. We conclude that standardization of some kind, particularly stellar parameters, improves the consistency between methods. However, because results did not converge as more free parameters were standardized, it is clear there are inherent issues within the techniques that need to be reconciled. Therefore, we encourage more conversation and transparency within the community such that stellar abundance determinations can be reproducible as well as accurate and precise.

  9. Correlation between near infrared spectroscopy and electrical techniques in measuring skin moisture content

    International Nuclear Information System (INIS)

    Mohamad, M; Sabbri, A R M; Jafri, M Z Mat; Omar, A F

    2014-01-01

    Near infrared (NIR) spectroscopy technique serves as an important tool for the measurement of moisture content of skin owing to the advantages it has over the other techniques. The purpose of the study is to develop a correlation between NIR spectrometer with electrical conventional techniques for skin moisture measurement. A non-invasive measurement of moisture content of skin was performed on different part of human face and hand under control environment (temperature 21 ± 1 °C, relative humidity 45 ± 5 %). Ten healthy volunteers age between 21-25 (male and female) participated in this study. The moisture content of skin was measured using DermaLab ® USB Moisture Module, Scalar Moisture Checker and NIR spectroscopy (NIRQuest). Higher correlation was observed between NIRQuest and Dermalab moisture probe with a coefficient of determination (R 2 ) above 70 % for all the subjects. However, the value of R 2 between NIRQuest and Moisture Checker was observed to be lower with the R 2 values ranges from 51.6 to 94.4 %. The correlation of NIR spectroscopy technique successfully developed for measuring moisture content of the skin. The analysis of this correlation can help to establish novel instruments based on an optical system in clinical used especially in the dermatology field

  10. Red blood cell-deformability measurement: review of techniques.

    Science.gov (United States)

    Musielak, M

    2009-01-01

    Cell-deformability characterization involves general measurement of highly complex relationships between cell biology and physical forces to which the cell is subjected. The review takes account of the modern technical solutions simulating the action of the force applied to the red blood cell in macro- and microcirculation. Diffraction ektacytometers and rheoscopes measure the mean deformability value for the total red blood cell population investigated and the deformation distribution index of individual cells, respectively. Deformation assays of a whole single cell are possible by means of optical tweezers. The single cell-measuring setups for micropipette aspiration and atomic force microscopy allow conducting a selective investigation of deformation parameters (e.g., cytoplasm viscosity, viscoelastic membrane properties). The distinction between instrument sensitivity to various RBC-rheological features as well as the influence of temperature on measurement are discussed. The reports quoted confront fascinating possibilities of the techniques with their medical applications since the RBC-deformability has the key position in the etiology of a wide range of conditions.

  11. Neutron beam applications; development of texture measuring technique using 1-dimensional PSD

    Energy Technology Data Exchange (ETDEWEB)

    Park, No Jin; Lee, Moon Kyu; Joung, Tae Won; Lee, In Sung [Kumoh National University of Technology, Kumi (Korea)

    2002-03-01

    The new developed materials have often a low crystal symmetry or/and multi-phase state. Because the diffraction patterns of those materials are very complex and some peaks are overlapped, the measured pole figures with a conventional detector (0-dimensional detector) are not sufficient to use for the texture analysis. And also the widely broaden diffraction patterns caused by sever deformation, can only measured with lots of measuring errors using 0-dimensional detector. In this study the 1-dimensional and 2-dimensional position sensitive detector(PSD) is used such pattern to analyse. With PSD the more accurate pole figures can be measured, and the texture analysis, the estimation of the properties are determined more precisely. The measurement using PSD needs special technique for the analysis of the measured pattern. In this study the measuring and analysing technique is developed and compared with the conventional detector. 11 refs., 92 figs., 21 tabs. (Author)

  12. Application of stereo photogrammetric techniques for measuring African Elephants

    Directory of Open Access Journals (Sweden)

    A. J Hall-Martin

    1979-12-01

    Full Text Available Measurements of shoulder height and back length of African elephants were obtained by means of stereo photogrammetric techniques. A pair of Zeiss UMK 10/1318 cameras, mounted on a steel frame on the back of a vehicle, were used to photograph the elephants in the Addo Elephant National Park, Republic of South Africa. Several modifications of normal photogrammetry procedure applicable to the field situation (eg. control points and the computation of results (eg. relative orientation are briefly mentioned. Six elephants were immobilised after being photographed and the measurements obtained from them agreed within a range of 1 cm-10 cm with the photogrammetric measurements.

  13. Measurement of Walking Ground Reactions in Real-Life Environments: A Systematic Review of Techniques and Technologies.

    Science.gov (United States)

    Shahabpoor, Erfan; Pavic, Aleksandar

    2017-09-12

    Monitoring natural human gait in real-life environments is essential in many applications, including quantification of disease progression, monitoring the effects of treatment, and monitoring alteration of performance biomarkers in professional sports. Nevertheless, developing reliable and practical techniques and technologies necessary for continuous real-life monitoring of gait is still an open challenge. A systematic review of English-language articles from scientific databases including Scopus, ScienceDirect, Pubmed, IEEE Xplore, EBSCO and MEDLINE were carried out to analyse the 'accuracy' and 'practicality' of the current techniques and technologies for quantitative measurement of the tri-axial walking ground reactions outside the laboratory environment, and to highlight their strengths and shortcomings. In total, 679 relevant abstracts were identified, 54 full-text papers were included in the paper and the quantitative results of 17 papers were used for meta-analysis and comparison. Three classes of methods were reviewed: (1) methods based on measured kinematic data; (2) methods based on measured plantar pressure; and (3) methods based on direct measurement of ground reactions. It was found that all three classes of methods have competitive accuracy levels with methods based on direct measurement of the ground reactions showing highest accuracy while being least practical for long-term real-life measurement. On the other hand, methods that estimate ground reactions using measured body kinematics show highest practicality of the three classes of methods reviewed. Among the most prominent technical and technological challenges are: (1) reducing the size and price of tri-axial load-cells; (2) improving the accuracy of orientation measurement using IMUs; (3) minimizing the number and optimizing the location of required IMUs for kinematic measurement; (4) increasing the durability of pressure insole sensors, and (5) enhancing the robustness and versatility of the

  14. Measurement of Walking Ground Reactions in Real-Life Environments: A Systematic Review of Techniques and Technologies

    Directory of Open Access Journals (Sweden)

    Erfan Shahabpoor

    2017-09-01

    Full Text Available Monitoring natural human gait in real-life environments is essential in many applications, including quantification of disease progression, monitoring the effects of treatment, and monitoring alteration of performance biomarkers in professional sports. Nevertheless, developing reliable and practical techniques and technologies necessary for continuous real-life monitoring of gait is still an open challenge. A systematic review of English-language articles from scientific databases including Scopus, ScienceDirect, Pubmed, IEEE Xplore, EBSCO and MEDLINE were carried out to analyse the ‘accuracy’ and ‘practicality’ of the current techniques and technologies for quantitative measurement of the tri-axial walking ground reactions outside the laboratory environment, and to highlight their strengths and shortcomings. In total, 679 relevant abstracts were identified, 54 full-text papers were included in the paper and the quantitative results of 17 papers were used for meta-analysis and comparison. Three classes of methods were reviewed: (1 methods based on measured kinematic data; (2 methods based on measured plantar pressure; and (3 methods based on direct measurement of ground reactions. It was found that all three classes of methods have competitive accuracy levels with methods based on direct measurement of the ground reactions showing highest accuracy while being least practical for long-term real-life measurement. On the other hand, methods that estimate ground reactions using measured body kinematics show highest practicality of the three classes of methods reviewed. Among the most prominent technical and technological challenges are: (1 reducing the size and price of tri-axial load-cells; (2 improving the accuracy of orientation measurement using IMUs; (3 minimizing the number and optimizing the location of required IMUs for kinematic measurement; (4 increasing the durability of pressure insole sensors, and (5 enhancing the robustness and

  15. Exposure measuring techniques for wide band mobile radio-communications

    International Nuclear Information System (INIS)

    Trinchero, S.; Benedetto, A.; Anglesio, L.; D'Amore, G.; Trinchero, D.

    2004-01-01

    The paper illustrates the limits and performances of different experimental monitoring techniques, which are applied to digitally modulated radiofrequency electromagnetic fields used for mobile telecommunications. Different experimental set-ups have been developed, verified and applied for the analysis and characterisation of wide band probes and narrow band measuring procedures. (authors)

  16. A technique of measuring neutron spectrum

    International Nuclear Information System (INIS)

    Sarkar, P.K.; Kirthi, K.N.; Ganguly, A.K.

    1975-01-01

    Plastic scintillators have been used to measure fast neutron spectrum from various sources. Gamma background discrimination has been done by selecting thin scintillators and thereby achieving near 100% transmission of Compton-edge electrons. The measured distribution has been unfolded by using an iterative least square technique. This gives minimum variance and maximum likelihood estimate with error minimised. Smoothening of the observed distribution has been done by Fourier and time series analyses. The method developed is applicable in principle for the determination of spectra of high energy neutrons ranging from 1 MeV to 70 MeV and beyond. However, practical application of the method is limited by the non-availability of cross-section data for various neutron induced reactions with carbon and hydrogen present in the polymerised polystyrene scintillator. This procedure has been adopted in the present work for spectral determination up to 14 MeV neutrons using the published value of reaction and scattering cross-sections. The spectra of Po-Be, Pu-Be, Am-Be and Ra-Be arrived at agree well with the published spectra obtained by other methods. Spectrum from spontaneous fission of Cf-252 have also been measured and fitted to the expression N(E)=Esup(1/2)exp(-E/T). The fitted parameter T and spectral details agree well with those in published literature

  17. Viscosity measurement techniques in Dissipative Particle Dynamics

    Science.gov (United States)

    Boromand, Arman; Jamali, Safa; Maia, Joao M.

    2015-11-01

    In this study two main groups of viscosity measurement techniques are used to measure the viscosity of a simple fluid using Dissipative Particle Dynamics, DPD. In the first method, a microscopic definition of the pressure tensor is used in equilibrium and out of equilibrium to measure the zero-shear viscosity and shear viscosity, respectively. In the second method, a periodic Poiseuille flow and start-up transient shear flow is used and the shear viscosity is obtained from the velocity profiles by a numerical fitting procedure. Using the standard Lees-Edward boundary condition for DPD will result in incorrect velocity profiles at high values of the dissipative parameter. Although this issue was partially addressed in Chatterjee (2007), in this work we present further modifications (Lagrangian approach) to the original LE boundary condition (Eulerian approach) that will fix the deviation from the desired shear rate at high values of the dissipative parameter and decrease the noise to signal ratios in stress measurement while increases the accessible low shear rate window. Also, the thermostat effect of the dissipative and random forces is coupled to the dynamic response of the system and affects the transport properties like the viscosity and diffusion coefficient. We investigated thoroughly the dependency of viscosity measured by both Eulerian and Lagrangian methodologies, as well as numerical fitting procedures and found that all the methods are in quantitative agreement.

  18. Actively stabilized optical fiber interferometry technique for online/in-process surface measurement

    International Nuclear Information System (INIS)

    Wang Kaiwei; Martin, Haydn; Jiang Xiangqian

    2008-01-01

    In this paper, we report the recent progress in optical-beam scanning fiber interferometry for potential online nanoscale surface measurement based on the previous research. It attempts to generate a robust and miniature measurement device for future development into a multiprobe array measurement system. In this research, both fiber-optic-interferometry and the wavelength-division-multiplexing techniques have been used, so that the optical probe and the optical interferometer are well spaced and fast surface scanning can be carried out, allowing flexibility for online measurement. In addition, this system provides a self-reference signal to stabilize the optical detection with high common-mode noise suppression by adopting an active phase tracking and stabilization technique. Low-frequency noise was significantly reduced compared with unstabilized result. The measurement of a sample surface shows an attained repeatability of 3.3 nm

  19. Techniques, processes, and measures for software safety and reliability

    International Nuclear Information System (INIS)

    Sparkman, D.

    1992-01-01

    The purpose of this report is to provide a detailed survey of current recommended practices and measurement techniques for the development of reliable and safe software-based systems. This report is intended to assist the United States Nuclear Reaction Regulation (NRR) in determining the importance and maturity of the available techniques and in assessing the relevance of individual standards for application to instrumentation and control systems in nuclear power generating stations. Lawrence Livermore National Laboratory (LLNL) provides technical support for the Instrumentation and Control System Branch (ICSB) of NRRin advanced instrumentation and control systems, distributed digital systems, software reliability, and the application of verificafion and validafion for the development of software

  20. AUTOMATED TECHNIQUE FOR FLOW MEASUREMENTS FROM MARIOTTE RESERVOIRS.

    Science.gov (United States)

    Constantz, Jim; Murphy, Fred

    1987-01-01

    The mariotte reservoir supplies water at a constant hydraulic pressure by self-regulation of its internal gas pressure. Automated outflow measurements from mariotte reservoirs are generally difficult because of the reservoir's self-regulation mechanism. This paper describes an automated flow meter specifically designed for use with mariotte reservoirs. The flow meter monitors changes in the mariotte reservoir's gas pressure during outflow to determine changes in the reservoir's water level. The flow measurement is performed by attaching a pressure transducer to the top of a mariotte reservoir and monitoring gas pressure changes during outflow with a programmable data logger. The advantages of the new automated flow measurement techniques include: (i) the ability to rapidly record a large range of fluxes without restricting outflow, and (ii) the ability to accurately average the pulsing flow, which commonly occurs during outflow from the mariotte reservoir.

  1. In vivo mitochondrial oxygen tension measured by a delayed fluorescence lifetime technique

    NARCIS (Netherlands)

    Mik, Egbert G.; Johannes, Tanja; Zuurbier, Coert J.; Heinen, Andre; Houben-Weerts, Judith H. P. M.; Balestra, Gianmarco M.; Stap, Jan; Beek, Johan F.; Ince, Can

    2008-01-01

    Mitochondrial oxygen tension (mitoPO(2)) is a key parameter for cellular function, which is considered to be affected under various pathophysiological circumstances. Although many techniques for assessing in vivo oxygenation are available, no technique for measuring mitoPO(2) in vivo exists. Here we

  2. Applied potential tomography. A new noninvasive technique for measuring gastric emptying

    International Nuclear Information System (INIS)

    Avill, R.; Mangnall, Y.F.; Bird, N.C.; Brown, B.H.; Barber, D.C.; Seagar, A.D.; Johnson, A.G.; Read, N.W.

    1987-01-01

    Applied potential tomography is a new, noninvasive technique that yields sequential images of the resistivity of gastric contents after subjects have ingested a liquid or semisolid meal. This study validates the technique as a means of measuring gastric emptying. Experiments in vitro showed an excellent correlation between measurements of resistivity and either the square of the radius of a glass rod or the volume of water in a spherical balloon when both were placed in an oval tank containing saline. Altering the lateral position of the rod in the tank did not alter the values obtained. Images of abdominal resistivity were also directly correlated with the volume of air in a gastric balloon. Profiles of gastric emptying of liquid meals obtained using applied potential tomography were very similar to those obtained using scintigraphy or dye dilution techniques, provided that acid secretion was inhibited by cimetidine. Profiles of emptying of a mashed potato meal using applied potential tomography were also very similar to those obtained by scintigraphy. Measurements of the emptying of a liquid meal from the stomach were reproducible if acid secretion was inhibited by cimetidine. Thus, applied potential tomography is an accurate and reproducible method of measuring gastric emptying of liquids and particulate food. It is inexpensive, well tolerated, easy to use, and ideally suited for multiple studies in patients, even those who are pregnant

  3. Applied potential tomography. A new noninvasive technique for measuring gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Avill, R.; Mangnall, Y.F.; Bird, N.C.; Brown, B.H.; Barber, D.C.; Seagar, A.D.; Johnson, A.G.; Read, N.W.

    1987-04-01

    Applied potential tomography is a new, noninvasive technique that yields sequential images of the resistivity of gastric contents after subjects have ingested a liquid or semisolid meal. This study validates the technique as a means of measuring gastric emptying. Experiments in vitro showed an excellent correlation between measurements of resistivity and either the square of the radius of a glass rod or the volume of water in a spherical balloon when both were placed in an oval tank containing saline. Altering the lateral position of the rod in the tank did not alter the values obtained. Images of abdominal resistivity were also directly correlated with the volume of air in a gastric balloon. Profiles of gastric emptying of liquid meals obtained using applied potential tomography were very similar to those obtained using scintigraphy or dye dilution techniques, provided that acid secretion was inhibited by cimetidine. Profiles of emptying of a mashed potato meal using applied potential tomography were also very similar to those obtained by scintigraphy. Measurements of the emptying of a liquid meal from the stomach were reproducible if acid secretion was inhibited by cimetidine. Thus, applied potential tomography is an accurate and reproducible method of measuring gastric emptying of liquids and particulate food. It is inexpensive, well tolerated, easy to use, and ideally suited for multiple studies in patients, even those who are pregnant.

  4. Evaluation of Uranium-235 Measurement Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kaspar, Tiffany C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dibert, Mark W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-23

    Monolithic U-Mo fuel plates are rolled to final fuel element form from the original cast ingot, and thus any inhomogeneities in 235U distribution present in the cast ingot are maintained, and potentially exaggerated, in the final fuel foil. The tolerance for inhomogeneities in the 235U concentration in the final fuel element foil is very low. A near-real-time, nondestructive technique to evaluate the 235U distribution in the cast ingot is required in order to provide feedback to the casting process. Based on the technical analysis herein, gamma spectroscopy has been recommended to provide a near-real-time measure of the 235U distribution in U-Mo cast plates.

  5. MXLKID: a maximum likelihood parameter identifier

    International Nuclear Information System (INIS)

    Gavel, D.T.

    1980-07-01

    MXLKID (MaXimum LiKelihood IDentifier) is a computer program designed to identify unknown parameters in a nonlinear dynamic system. Using noisy measurement data from the system, the maximum likelihood identifier computes a likelihood function (LF). Identification of system parameters is accomplished by maximizing the LF with respect to the parameters. The main body of this report briefly summarizes the maximum likelihood technique and gives instructions and examples for running the MXLKID program. MXLKID is implemented LRLTRAN on the CDC7600 computer at LLNL. A detailed mathematical description of the algorithm is given in the appendices. 24 figures, 6 tables

  6. Measurement of the Dielectric Constant of Seawater at L-Band: Techniques and Measurements

    Science.gov (United States)

    Lang, R.; Utku, C.; Tarkocin, Y.; LeVine, D.

    2009-01-01

    Satellite instruments, that will monitor salinity from space in the near future, require an accurate relationship between salinity/temperature and seawater dielectric constant. This paper will review measurements that were made of the dielectric constant of seawater during the past several years. The objective of the measurements is to determine the dependence of the dielectric constant of seawater on salinity and on temperature, more accurately than in the past. by taking advantage of modem instrumentation. The measurements of seawater permittivity have been performed as a function of salinity and temperature using a transmission resonant cavity technique. The measurements have been made in the salinity range of 10 to 38 psu and in the temperature range of IOU C to 35 C. These results will be useful in algorithm development for sensor systems such as SMOS and Aquarius. The measurement system consists of a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The diameter of the tube has been made very small so that the amount of seawater introduced in the cavity is small - thus maintaining the sensitivity of the measurements and allowing the use of perturbation theory predicting the seawater permittivity. The change in resonant frequency and the change in cavity Q can be used to determine the real and imaginary pare of the dielectric constant of seawater introduced into the slender tube. The microwave measurements are made by an HPS722D network analyzer. The cavity has been immersed in a uateriethylene-glycol bath which is connected to a Lauda circulator. The circulator keeps the brass cavity at a temperature constant to within 0.01 degrees. The system is automated using a Visual Basic program to control the analyzer and to collect the data. The results of the dielectric constant measurements of seawater will be presented. The measurement results will be

  7. Application of H/V technique on different soils using ambient vibration measurements and earthquakes

    International Nuclear Information System (INIS)

    Schmidt-Diaz, Victor

    2016-01-01

    Four techniques to identify the fundamental frequency (f0) for 26 different sites were applied. These techniques correspond to spectral ratios based on the recording of: ambient vibration using an accelerograph (denominated VAA), ambient vibration using a seismograph (VAS), total seismic records (ST) and a time window of 5 s staring at S waves arrives in the seismic records (SOS). Better results were achieved when VAA was applied during the day (at 8 am and 3 pm). When VAA at 3 pm was compared to VAS at day time, it was observed that in the 58% of the analyzed cases the shapes and amplitudes of the spectral ratios were different, which means that VAA is not an appropriated technique to identify f0 based on that the results from VAS are the correct ones. It is affirmed based on its similarity to ST and SOS techniques in a 75% of the studied cases. These last two techniques are better justified in both mathematical and physical fundaments. (author) [es

  8. Developing an instrument to measure emotional behaviour abilities of meaningful learning through the Delphi technique.

    Science.gov (United States)

    Cadorin, Lucia; Bagnasco, Annamaria; Tolotti, Angela; Pagnucci, Nicola; Sasso, Loredana

    2017-09-01

    To identify items for a new instrument that measures emotional behaviour abilities of meaningful learning, according to Fink's Taxonomy. Meaningful learning is an active process that promotes a wider and deeper understanding of concepts. It is the result of an interaction between new and previous knowledge and produces a long-term change of knowledge and skills. To measure meaningful learning capability, it is very important in the education of health professionals to identify problems or special learning needs. For this reason, it is necessary to create valid instruments. A Delphi Study technique was implemented in four phases by means of e-mail. The study was conducted from April-September 2015. An expert panel consisting of ten researchers with experience in Fink's Taxonomy was established to identify the items of the instrument. Data were analysed for conceptual description and item characteristics and attributes were rated. Expert consensus was sought in each of these phases. An 87·5% consensus cut-off was established. After four rounds, consensus was obtained for validation of the content of the instrument 'Assessment of Meaningful learning Behavioural and Emotional Abilities'. This instrument consists of 56 items evaluated on a 6-point Likert-type scale. Foundational Knowledge, Application, Integration, Human Dimension, Caring and Learning How to Learn were the six major categories explored. This content validated tool can help educators (teachers, trainers and tutors) to identify and improve the strategies to support students' learning capability, which could increase their awareness of and/or responsibility in the learning process. © 2017 John Wiley & Sons Ltd.

  9. Electron transport measurements in methane using an improved pulsed Townsend technique

    International Nuclear Information System (INIS)

    Hunter, S.R.; Carter, J.G.; Christophorou, L.G.

    1986-01-01

    An improved pulsed Townsend technique for the measurement of electron transport parameters in gases is described. The accuracy and sensitivity of the technique have been investigated by performing, respectively, electron attachment coefficient measurements in pure O 2 over a wide range of E/N at selected O 2 pressures and by determining the electron attachment and ionization coefficients and electron drift velocity in CH 4 over a wide E/N range. Good agreement has been obtained between the present and the previously published electron attachment coefficients in O 2 and for the drift velocity measurements in CH 4 . The data on the electron attachment coefficient in CH 4 (measured for the first time) showed that with the present improved pulsed Townsend method, electron attachment coefficients up to 10 times smaller than the ionization coefficients at a given E/N value can be accurately measured. Our measurements of the electron attachment and ionization coefficients in CH 4 are in good agreement with a Boltzmann equation analysis of the electron gain and loss processes in CH 4 using published electron scattering cross sections for this molecule

  10. A rapid and robust gradient measurement technique using dynamic single-point imaging.

    Science.gov (United States)

    Jang, Hyungseok; McMillan, Alan B

    2017-09-01

    We propose a new gradient measurement technique based on dynamic single-point imaging (SPI), which allows simple, rapid, and robust measurement of k-space trajectory. To enable gradient measurement, we utilize the variable field-of-view (FOV) property of dynamic SPI, which is dependent on gradient shape. First, one-dimensional (1D) dynamic SPI data are acquired from a targeted gradient axis, and then relative FOV scaling factors between 1D images or k-spaces at varying encoding times are found. These relative scaling factors are the relative k-space position that can be used for image reconstruction. The gradient measurement technique also can be used to estimate the gradient impulse response function for reproducible gradient estimation as a linear time invariant system. The proposed measurement technique was used to improve reconstructed image quality in 3D ultrashort echo, 2D spiral, and multi-echo bipolar gradient-echo imaging. In multi-echo bipolar gradient-echo imaging, measurement of the k-space trajectory allowed the use of a ramp-sampled trajectory for improved acquisition speed (approximately 30%) and more accurate quantitative fat and water separation in a phantom. The proposed dynamic SPI-based method allows fast k-space trajectory measurement with a simple implementation and no additional hardware for improved image quality. Magn Reson Med 78:950-962, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  11. Searching for Moral Dumbfounding: Identifying Measurable Indicators of Moral Dumbfounding

    Directory of Open Access Journals (Sweden)

    Cillian McHugh

    2017-10-01

    Full Text Available Moral dumbfounding is defined as maintaining a moral judgement, without supporting reasons. The most cited demonstration of dumbfounding does not identify a specific measure of dumbfounding and has not been published in peer-review form, or directly replicated. Despite limited empirical examination, dumbfounding has been widely discussed in moral psychology. The present research examines the reliability with which dumbfounding can be elicited, and aims to identify measureable indicators of dumbfounding. Study 1 aimed at establishing the effect that is reported in the literature. Participants read four scenarios and judged the actions described. An Interviewer challenged participants’ stated reasons for judgements. Dumbfounding was evoked, as measured by two indicators, admissions of not having reasons (17%, unsupported declarations (9% with differences between scenarios. Study 2 measured dumbfounding as the selecting of an unsupported declaration as part of a computerised task. We observed high rates of dumbfounding across all scenarios. Studies 3a (college sample and 3b (MTurk sample, addressing limitations in Study 2, replaced the unsupported declaration with an admission of having no reason, and included open-ended responses that were coded for unsupported declarations. As predicted, lower rates of dumbfounding were observed (3a 20%; 3b 16%; or 3a 32%; 3b 24% including unsupported declarations in open-ended responses. Two measures provided evidence for dumbfounding across three studies; rates varied with task type (interview/computer task, and with the particular measure being employed (admissions of not having reasons/unsupported declarations. Possible cognitive processes underlying dumbfounding and limitations of methodologies used are discussed as a means to account for this variability.

  12. Technique to measure contact angle of micro/nanodroplets using atomic force microscopy

    International Nuclear Information System (INIS)

    Jung, Yong Chae; Bhushan, Bharat

    2008-01-01

    Contact angle is the primary parameter that characterizes wetting; however, the measurement techniques have been limited to droplets with a diameter as low as about 50 μm. The authors developed an atomic force microscopy-based technique to measure the contact angle of micro- and nanodroplets deposited using a modified nanoscale dispensing tip. The obtained contact angle results were compared with those of a macrodroplet (2.1 mm diameter). It was found that the contact angle on various surfaces decreases with decreasing the droplet size

  13. Measurements of aerosol fluxes to Speulder forest using a micrometeorological technique

    DEFF Research Database (Denmark)

    Gallagher, M.W.; Beswick, K.M.; Duyzer, J.

    1997-01-01

    It has often been stated that micrometeorological and throughfall measurements of dry deposition differ by an order of magnitude with the results being highly variable and difficult to interpret or reconcile. We present measurements by the eddy correlation method of sub-micron aerosol deposition...... to a forest and show that they are large, typically 1 cm s(-1) or more. We compare the measurements with literature values obtained by throughfall and related techniques. The results, rather than being irreconcilable, show a clear and consistent behaviour in deposition velocity across the aerosol size...... spectrum, despite the very different techniques involved. There would appear to be a contradiction with previously assumed model predictions of aerosol deposition Velocity to forests and rough vegetated surfaces particularly for particles in the size range 0.1-1.0 mu m where collection efficiencies appear...

  14. Tracer-based laser-induced fluorescence measurement technique for quantitative fuel/air-ratio measurements in a hydrogen internal combustion engine.

    Science.gov (United States)

    Blotevogel, Thomas; Hartmann, Matthias; Rottengruber, Hermann; Leipertz, Alfred

    2008-12-10

    A measurement technique for the quantitative investigation of mixture formation processes in hydrogen internal combustion engines (ICEs) has been developed using tracer-based laser-induced fluorescence (TLIF). This technique can be employed to fired and motored engine operation. The quantitative TLIF fuel/air-ratio results have been verified by means of linear Raman scattering measurements. Exemplary results of the simultaneous investigation of mixture formation and combustion obtained at an optical accessible hydrogen ICE are shown.

  15. Task Oriented Evaluation of Module Extraction Techniques

    Science.gov (United States)

    Palmisano, Ignazio; Tamma, Valentina; Payne, Terry; Doran, Paul

    Ontology Modularization techniques identify coherent and often reusable regions within an ontology. The ability to identify such modules, thus potentially reducing the size or complexity of an ontology for a given task or set of concepts is increasingly important in the Semantic Web as domain ontologies increase in terms of size, complexity and expressivity. To date, many techniques have been developed, but evaluation of the results of these techniques is sketchy and somewhat ad hoc. Theoretical properties of modularization algorithms have only been studied in a small number of cases. This paper presents an empirical analysis of a number of modularization techniques, and the modules they identify over a number of diverse ontologies, by utilizing objective, task-oriented measures to evaluate the fitness of the modules for a number of statistical classification problems.

  16. Activities at Forschungszentrum Juelich in Safeguards Analytical Techniques and Measurements

    International Nuclear Information System (INIS)

    Duerr, M.; Knott, A.; Middendorp, R.; Niemeyer, I.; Kueppers, S.; Zoriy, M.; Froning, M.; Bosbach, D.

    2015-01-01

    The application of safeguards by the IAEA involves analytical measurements of samples taken during inspections. The development and advancement of analytical techniques with support from the Member States contributes to strengthened and more efficient verification of compliance with non-proliferation obligations. Since recently, a cooperation agreement has been established between Forschungszentrum Juelich and the IAEA in the field of analytical services. The current working areas of Forschungszentrum Juelich are: (i) Production of synthetic micro-particles as calibration standard and reference material for particle analysis, (ii) qualification of the Forschungszentrum Juelich as a member of the IAEA network of analytical laboratories for safeguards (NWAL), and (iii) analysis of impurities in nuclear material samples. With respect to the synthesis of particles, a dedicated setup for the production of uranium particles is being developed, which addresses the urgent need for material tailored for its use in quality assurance and quality control measures for particle analysis of environmental swipe samples. Furthermore, Forschungszentrum Juelich has been nominated as a candidate laboratory for membership in the NWAL network. To this end, analytical capabilities at Forschungszentrum Juelich have been joined to form an analytical service within a dedicated quality management system. Another activity is the establishment of analytical techniques for impurity analysis of uranium-oxide, mainly focusing on inductively coupled mass spectrometry. This contribution will present the activities at Forschungszentrum Juelich in the area of analytical measurements and techniques for nuclear verification. (author)

  17. Acoustic Measurements in Opera Houses: Comparison Between Different Techniques and Equipment

    Science.gov (United States)

    FAUSTI, P.; FARINA, A.

    2000-04-01

    In room acoustics, many objective parameters to quantify subjective impressions have been introduced. These quantities can be measured by using a wide variety of powerful tools and equipment. The results can be influenced by the measurement techniques and instruments used. Furthermore, the results also depend on the measurement positions and on the condition of the hall (full, empty, etc.). The aim of this work is to define a tightly standardized measurement procedure for the collection of a complete objective description of an opera house's acoustics. In this paper some of the results obtained by the authors after measurements made in three different halls are presented. Comparisons were made both between different hardware and software tools (real-time analyzer, DAT, PC-board, source, microphones, post-processing software) and between different measurement methods (interrupted stationary noise, true-impulse, pseudo-random white noise with impulse-response doconvolution, sine sweep) as well as between different positions in the halls, with and without the presence of musicians and audience. The results have shown that the differences obtained when using different measurement techniques and equipment are not of significant importance. The only effective differences were found regarding the recording techniques, as the monaural measurements give appreciably different results from the average of left and right channel of binaural measurements. Slightly different results were alsofound between true impulsive sources (pistol shots, balloons) and omni-directional (dodecahedral) loudspeakers. Attention must be paid to the signal-to-noise ratio, as this can influence the correct calculation of some acoustical parameters. Some differences, not as great as expected, were found in the results with and without the musicians in the orchestra shell and with and without the audience in the hall. This is probably due to the high sound absorption that is typical in Italian opera

  18. Application of interferometry and Faraday rotation techniques for density measurements on ITER

    International Nuclear Information System (INIS)

    Snider, R.T.; Carlstrom, T.N.; Ma, C.H.; Peebles, W.A.

    1995-01-01

    There is a need for real time, reliable density measurement for density control, compatible with the restricted access and radiation environment on ITER. Line average density measurements using microwave or laser interferometry techniques have proven to be robust and reliable for density control on contemporary tokamaks. In ITER, the large path length, high density and density gradients, limit the wavelength of a probing beam to shorter then about 50 microm due to refraction effects. In this paper the authors consider the design of short wavelength vibration compensated interferometers and Faraday rotation techniques for density measurements on ITER. These techniques allow operation of the diagnostics without a prohibitively large vibration isolated structure and permits the optics to be mounted directly on the radial port plugs on ITER. A beam path designed for 10.6 microm (CO2 laser) with a tangential path through the plasma allows both an interferometer and a Faraday rotation measurement of the line average density with good density resolution while avoiding refraction problems. Plasma effects on the probing beams and design tradeoffs will be discussed along with radiation and long pulse issues. A proposed layout of the diagnostic for ITER will be present

  19. X-ray radiographic technique for measuring density uniformity of silica aerogel

    International Nuclear Information System (INIS)

    Tabata, Makoto; Hatakeyama, Yoshikiyo; Adachi, Ichiro; Morita, Takeshi; Nishikawa, Keiko

    2013-01-01

    This paper proposes a new X-ray radiographic technique for measuring density uniformity of silica aerogels used as radiator in proximity-focusing ring-imaging Cherenkov detectors. To obtain high performance in a large-area detector, a key characteristic of radiator is the density (i.e. refractive index) uniformity of an individual aerogel monolith. At a refractive index of n=1.05, our requirement for the refractive index uniformity in the transverse plane direction of an aerogel tile is |δ(n−1)/(n−1)|<4% in a focusing dual layer radiator (with different refractive indices) scheme. We applied the radiographic technique to evaluate the density uniformity of our original aerogels from a trial production and that of Panasonic products (SP-50) as a reference, and to confirm they have sufficient density uniformity within ±1% along the transverse plane direction. The measurement results show that the proposed technique can quantitatively estimate the density uniformity of aerogels.

  20. Attempts to develop a new nuclear measurement technique of β-glucuronidase levels in biological samples

    International Nuclear Information System (INIS)

    Unak, T.; Avcibasi, U.; Yildirim, Y.; Cetinkaya, B.

    2003-01-01

    β-Glucuronidase is one of the most important hydrolytic enzymes in living systems and plays an essential role in the detoxification pathway of toxic materials incorporated into the metabolism. Some organs, especially liver and some tumour tissues, have high level of β-glucuronidase activity. As a result the enzymatic activity of some kind of tumour cells, the radiolabelled glucuronide conjugates of cytotoxic, as well as radiotoxic compounds have potentially very valuable diagnostic and therapeutic applications in cancer research. For this reason, a sensitive measurement of β-glucuronidase levels in normal and tumour tissues is a very important step for these kinds of applications. According to the classical measurement method of β-glucuronidase activity, in general, the quantity of phenolphthalein liberated from its glucuronide conjugate, i.e. phenolphthalein-glucuronide, by β-glucuronidase has been measured by use of the spectrophotometric technique. The lower detection limit of phenolphthalein by the spectrophotometric technique is about 1-3 mg. This means that the β-glucuronidase levels could not be detected in biological samples having lower levels of β-glucuronidase activity and therefore the applications of the spectrophotometric technique in cancer research are very seriously limited. Starting from this consideration, we recently attempted to develop a new nuclear technique to measure much lower concentrations of β-glucuronidase in biological samples. To improve the detection limit, phenolphthalein-glucuronide and also phenyl-N-glucuronide were radioiodinated with 131 I and their radioactivity was measured by use of the counting technique. Therefore, the quantity of phenolphthalein or aniline radioiodinated with 131 I and liberated by the deglucuronidation reactivity of β-glucuronidase was used in an attempt to measure levels lower than the spectrophotometric measurement technique. The results obtained clearly verified that 0.01 pg level of

  1. Techniques for beam impedance measurements above cutoff

    International Nuclear Information System (INIS)

    Lambertson, G.R.; Jacob, A.F.; Rimmer, R.A.; Voelker, F.

    1990-08-01

    Methods for measuring beam impedance above cutoff have been very limited. For design work on the ALS we have developed two techniques that yield data in the frequency domain with high sensitivity. The first is an extension of the wire method; the second utilizes traveling TM waves to simulate the beam's fields at the wall, and thus avoids the mechanical difficulties of mounting the wire. It is also more sensitive than the other method but the interpretation is complicated by the presence of higher order modes. With either method we were able to detect resonant peaks smaller than 1 Ohm at 10 GHz

  2. Near-field Light Scattering Techniques for Measuring Nanoparticle-Surface Interaction Energies and Forces.

    Science.gov (United States)

    Schein, Perry; Ashcroft, Colby K; O'Dell, Dakota; Adam, Ian S; DiPaolo, Brian; Sabharwal, Manit; Shi, Ce; Hart, Robert; Earhart, Christopher; Erickson, David

    2015-08-15

    Nanoparticles are quickly becoming commonplace in many commercial and industrial products, ranging from cosmetics to pharmaceuticals to medical diagnostics. Predicting the stability of the engineered nanoparticles within these products a priori remains an important and difficult challenge. Here we describe our techniques for measuring the mechanical interactions between nanoparticles and surfaces using near-field light scattering. Particle-surface interfacial forces are measured by optically "pushing" a particle against a reference surface and observing its motion using scattered near-field light. Unlike atomic force microscopy, this technique is not limited by thermal noise, but instead takes advantage of it. The integrated waveguide and microfluidic architecture allow for high-throughput measurements of about 1000 particles per hour. We characterize the reproducibility of and experimental uncertainty in the measurements made using the NanoTweezer surface instrument. We report surface interaction studies on gold nanoparticles with 50 nm diameters, smaller than previously reported in the literature using similar techniques.

  3. Application of neutron backscatter techniques to level measurement problems

    International Nuclear Information System (INIS)

    Leonardi-Cattolica, A.M.; McMillan, D.H.; Telfer, A.; Griffin, L.H.; Hunt, R.H.

    1982-01-01

    We have designed and built portable level detectors and fixed level monitors based on neutron scattering and detection principles. The main components of these devices, which we call neutron backscatter gauges, are a neutron emitting radioisotope, a neutron detector, and a ratemeter. The gauge is a good detector for hydrogen but is much less sensitive to most other materials. This allows level measurements of hydrogen bearing materials, such as hydrocarbons, to be made through the walls of metal vessels. Measurements can be made conveniently through steel walls which are a few inches thick. We have used neutron backscatter gauges in a wide variety of level measurement applications encountered in the petrochemical industry. In a number of cases, the neutron techniques have proven to be superior to conventional level measurement methods, including gamma ray methods

  4. Dimensional measuring techniques in the automotive and aircraft industry

    Science.gov (United States)

    Muench, K. H.; Baertlein, Hugh

    1994-03-01

    Optical tooling methods used in industry are rapidly being replaced by new electronic sensor techniques. The impact of new measuring technologies on the production process has caused major changes on the industrial shop floor as well as within industrial measurement systems. The paper deals with one particular industrial measuring system, the manual theodolite measuring system (TMS), within the aircraft and automobile industry. With TMS, setup, data capture, and data analysis are flexible enough to suit industry's demands regarding speed, accuracy, and mobility. Examples show the efficiency and the wide range of TMS applications. In cooperation with industry, the Video Theodolite System was developed. Its origin, functions, capabilities, and future plans are briefly described. With the VTS a major step has been realized in direction to vision systems for industrial applications.

  5. Measurement of moisture depth distribution in composite materials using positron lifetime technique

    International Nuclear Information System (INIS)

    Singh, J.J.; Holt, W.H.; Mock, W. Jr.; Mall, G.H.

    1980-01-01

    Fiber-reinforced resin matrix composites reportedly suffer significant degradation in their mechanical properties when exposed to hot, moist, environments for extended periods. Moisture weakens the fiber matrix bond as well as the matrix shear strength. An important factor in determining the extent of degradation is the depth distribution of moisture in the resin matrix. Despite the importance of measuring moisture distribution and its effects on composite material properties, not enough data are available on suitable nondestructive techniques for detecting and measuring moisture diffusion in organic composite materials. This paper addresses itself to the problem of measuring the moisture content of such materials, with special emphasis on its depth distribution, using positron lifetime technique

  6. Driver drowsiness detection using behavioral measures and machine learning techniques: A review of state-of-art techniques

    CSIR Research Space (South Africa)

    Ngxande, Mkhuseli

    2017-11-01

    Full Text Available This paper presents a literature review of driver drowsiness detection based on behavioral measures using machine learning techniques. Faces contain information that can be used to interpret levels of drowsiness. There are many facial features...

  7. Free-flight measurement technique in the free-piston high-enthalpy shock tunnel

    Science.gov (United States)

    Tanno, H.; Komuro, T.; Sato, K.; Fujita, K.; Laurence, S. J.

    2014-04-01

    A novel multi-component force-measurement technique has been developed and implemented at the impulse facility JAXA-HIEST, in which the test model is completely unrestrained during the test and thus experiences free-flight conditions for a period on the order of milliseconds. Advantages over conventional free-flight techniques include the complete absence of aerodynamic interference from a model support system and less variation in model position and attitude during the test itself. A miniature on-board data recorder, which was a key technology for this technique, was also developed in order to acquire and store the measured data. The technique was demonstrated in a HIEST wind-tunnel test campaign in which three-component aerodynamic force measurement was performed on a blunted cone of length 316 mm, total mass 19.75 kg, and moment of inertia 0.152 kgm2. During the test campaign, axial force, normal forces, and pitching moment coefficients were obtained at angles of attack from 14° to 32° under two conditions: H0 = 4 MJ/kg, P0 = 14 MPa; and H0 = 16 MJ/kg, P0 = 16 MPa. For the first, low-enthalpy condition, the test flow was considered a perfect gas; measurements were thus directly compared with those obtained in a conventional blow-down wind tunnel (JAXA-HWT2) to evaluate the accuracy of the technique. The second test condition was a high-enthalpy condition in which 85% of the oxygen molecules were expected to be dissociated; high-temperature real-gas effects were therefore evaluated by comparison with results obtained in perfect-gas conditions. The precision of the present measurements was evaluated through an uncertainty analysis, which showed the aerodynamic coefficients in the HIEST low enthalpy test agreeing well with those of JAXA-HWT2. The pitching-moment coefficient, however, showed significant differences between low- and high-enthalpy tests. These differences are thought to result from high-temperature real-gas effects.

  8. Intensity Modulation Techniques for Continuous-Wave Lidar for Column CO2 Measurements

    Science.gov (United States)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Kooi, S. A.; Fan, T. F.; Meadows, B.; Browell, E. V.; Erxleben, W. H.; McGregor, D.; Dobler, J. T.; Pal, S.; O'Dell, C.

    2017-12-01

    Global and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) and Linear Swept Frequency modulations to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that take advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques and provides very high (at sub-meter level) range resolution. We compare BPSK to linear swept frequency and introduce a new technique to eliminate sidelobes in situations from linear swept frequency where the SNR is high with results that rival BPSK. We also investigate the effects of non-linear modulators, which can in some circumstances degrade the orthogonality of the waveforms, and show how to avoid this. These techniques are used in a new data processing architecture written in

  9. Tritium measurement technique using ''in-bed'' calorimetry

    International Nuclear Information System (INIS)

    Klein, J.E.; Mallory, M.K.; Nobile, A. Jr.

    1991-01-01

    One of the new technologies that has been introduced to the Savannah River Site (SRS) is the production scale use of metal hydride technology to store, pump, and compress hydrogen isotopes. For tritium stored in metal hydride storage beds, a unique relationship does not exist between the amount of tritium in the bed and the pressure-volume-temperature properties of the hydride material. Determining the amount of tritium in a hydride bed after desorbing the contents of the bed to a tank and performing pressure, volume, temperature, and composition (PVTC) measurements is not practical due to long desorption/absorption times and the inability to remove tritium ''heels'' from the metal hydride materials under normal processing conditions. To eliminate the need to remove tritium from hydride storage beds for measurement purposes, and ''in-bed'' tritium calorimetric measurement technique has been developed. The steady-state temperature rise of a gas stream flowing through a jacketed metal hydride storage bed is measured and correlated with power input to electric heaters used to simulate the radiolytic power generated by the decay of tritium to 3 He. Temperature rise results for prototype metal hydride storage beds and the effects of using different gases in the bed are shown. Linear regression results shows that for 95% confidence intervals, temperature rise measurements can be obtained in 14 hours and have an accuracy of ±1.6% of a tritium filled hydride storage bed

  10. A semi-automatic technique for measurement of arterial wall from black blood MRI

    International Nuclear Information System (INIS)

    Ladak, Hanif M.; Thomas, Jonathan B.; Mitchell, J. Ross; Rutt, Brian K.; Steinman, David A.

    2001-01-01

    Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semi-automatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple

  11. Root resistance to cavitation is accurately measured using a centrifuge technique.

    Science.gov (United States)

    Pratt, R B; MacKinnon, E D; Venturas, M D; Crous, C J; Jacobsen, A L

    2015-02-01

    Plants transport water under negative pressure and this makes their xylem vulnerable to cavitation. Among plant organs, root xylem is often highly vulnerable to cavitation due to water stress. The use of centrifuge methods to study organs, such as roots, that have long vessels are hypothesized to produce erroneous estimates of cavitation resistance due to the presence of open vessels through measured samples. The assumption that roots have long vessels may be premature since data for root vessel length are sparse; moreover, recent studies have not supported the existence of a long-vessel artifact for stems when a standard centrifuge technique was used. We examined resistance to cavitation estimated using a standard centrifuge technique and compared these values with native embolism measurements for roots of seven woody species grown in a common garden. For one species we also measured vulnerability using single-vessel air injection. We found excellent agreement between root native embolism and the levels of embolism measured using a centrifuge technique, and with air-seeding estimates from single-vessel injection. Estimates of cavitation resistance measured from centrifuge curves were biologically meaningful and were correlated with field minimum water potentials, vessel diameter (VD), maximum xylem-specific conductivity (Ksmax) and vessel length. Roots did not have unusually long vessels compared with stems; moreover, root vessel length was not correlated to VD or to the vessel length of stems. These results suggest that root cavitation resistance can be accurately and efficiently measured using a standard centrifuge method and that roots are highly vulnerable to cavitation. The role of root cavitation resistance in determining drought tolerance of woody species deserves further study, particularly in the context of climate change. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Intercomparison of rod-worth measurement techniques in a LEU-HTR assembly

    International Nuclear Information System (INIS)

    Williams, T.; Chawla, R.

    1994-01-01

    The measurement of absorber-rod worths in the radial reflector of a LEU-HTR pebble bed system is described. Particular emphasis is placed on the choice of complementary measurement techniques to ensure that sensitivities to systematic errors in the calculated parameters used in the analysis are minimised. (author) 3 figs., 3 tabs., 8 refs

  13. A multi-slice sliding cell technique for diffusion measurements in liquid metals

    Science.gov (United States)

    Zhong, Langxiang; Hu, Jinliang; Geng, Yongliang; Zhu, Chunao; Zhang, Bo

    2017-09-01

    The long capillary and shear-cell techniques are traditionally used for diffusion measurements in liquid metals. Inspired by the idea of the shear-cell method, we have built a multi-slice sliding cell device for inter-diffusion measurements in liquid metals. The device is designed based on a linear sliding movement rather than a rotational shearing as used in the traditional shear-cell method. Compared with the normal shear-cell method, the present device is a more compact setup thus easier to handle. Also, it is expected to be easier to monitor with X-rays or neutrons if used in in situ experiments. A series of benchmark time-dependent diffusion experiments in Al-Cu melts carried out with the present technique reveal that accurate diffusion constants can be achieved only after a sufficient time. For short annealing times, the initial shearing process causing convective flow dominates the measurement and leads to an increase of the measured diffusion coefficient by a factor three. The diffusion data obtained for Al-Cu liquids are consistent with the most accurate data measured by the in situ X-ray radiography method under well controlled conditions of no temperature gradient or other perturbation. High accuracy and easy handling as well as superior adaptability make the present technique suitable for diffusion studies in liquid metals.

  14. Clinical Utility of Ultrasound Measurements of Plantar Fascia Width and Cross-Sectional AreaA Novel Technique.

    Science.gov (United States)

    Bisi-Balogun, Adebisi; Rector, Michael

    2017-09-01

    We sought to develop a standardized protocol for ultrasound (US) measurements of plantar fascia (PF) width and cross-sectional area (CSA), which may serve as additional outcome variables during US examinations of both healthy asymptomatic PF and in plantar fasciopathy and determine its interrater and intrarater reliability. Ten healthy individuals (20 feet) were enrolled. Participants were assessed twice by two raters each to determine intrarater and interrater reliability. For each foot, three transverse scans of the central bundle of the PF were taken at its insertion at the medial calcaneal tubercle, identified in real time on the plantar surface of the foot, using a fine wire technique. Reliability was determined using intraclass correlation coefficients (ICC), standard errors of measurement (SEM), and limits of agreement (LOA) expressed as percentages of the mean. Reliability of PF width and CSA measurements was determined using PF width and CSA measurements from one sonogram measured once and the mean of three measurements from three sonograms each measured once. Ultrasound measurements of PF width and CSA showed a mean of 18.6 ± 2.0 mm and 69.20 ± 13.6 mm 2 respectively. Intra-reliability within both raters showed an ICC > 0.84 for width and ICC > 0.92 for CSA as well as a SEM% and LOA% < 10% for both width and CSA. Inter-rater reliability showed an ICC of 0.82 for width and 0.87 for CSA as well as a SEM% and LOA% < 10% for width and a SEM% < 10% and LOA% < 20% for CSA. Relative and absolute reliability within and between raters were higher when using the mean of three sonographs compared to one sonograph. Using this novel technique, PF CSA and width may be determined reliably using measurements from one sonogram or the mean of three sonograms. Measurement of PF CSA and width in addition to already established thickness and echogenicity measurements provides additional information on structural properties of the PF for clinicians and researchers in healthy

  15. Comparative interpretations of renormalization inversion technique for reconstructing unknown emissions from measured atmospheric concentrations

    Science.gov (United States)

    Singh, Sarvesh Kumar; Kumar, Pramod; Rani, Raj; Turbelin, Grégory

    2017-04-01

    The study highlights a theoretical comparison and various interpretations of a recent inversion technique, called renormalization, developed for the reconstruction of unknown tracer emissions from their measured concentrations. The comparative interpretations are presented in relation to the other inversion techniques based on principle of regularization, Bayesian, minimum norm, maximum entropy on mean, and model resolution optimization. It is shown that the renormalization technique can be interpreted in a similar manner to other techniques, with a practical choice of a priori information and error statistics, while eliminating the need of additional constraints. The study shows that the proposed weight matrix and weighted Gram matrix offer a suitable deterministic choice to the background error and measurement covariance matrices, respectively, in the absence of statistical knowledge about background and measurement errors. The technique is advantageous since it (i) utilizes weights representing a priori information apparent to the monitoring network, (ii) avoids dependence on background source estimates, (iii) improves on alternative choices for the error statistics, (iv) overcomes the colocalization problem in a natural manner, and (v) provides an optimally resolved source reconstruction. A comparative illustration of source retrieval is made by using the real measurements from a continuous point release conducted in Fusion Field Trials, Dugway Proving Ground, Utah.

  16. New measurement techniques correct PU inventory in Japanese reprocessing plant

    International Nuclear Information System (INIS)

    2003-01-01

    Full text: At its briefing to the Japan Atomic Energy Commission on 28 January 2003, the Japan Safeguards Office (JSGO) of the Ministry of Education, Culture, Sports, Science and Technology (MEXT) announced that, due to the introduction of more precise sampling and analytical measurement techniques for measuring plutonium in the high active liquid waste (HALW) storage tanks at the Tokai Reprocessing Plant (TRP), the Japan Nuclear Cycle Development Institute (JNC) is correcting the amount of plutonium declared in past accountancy reports to the IAEA. The corrected amounts are expected to be in line with IAEA's own independent verification data and based on measurement methodologies endorsed by the IAEA. The IAEA has recognized for some time that the amount of nuclear material transferred to waste storage had not been adequately measured in the past and has worked with the facility operators and State authorities to introduce improved measurement techniques. IAEA Director General, Dr. Mohamed ElBaradei stressed however, that 'the Agency remains confident in its conclusion that no nuclear material has been diverted from the facility'. This conclusion is based on a range of activities under the NPT Safeguards Agreement between the Agency and Japan, as well as under the Additional Protocol to that Agreement which gives the Agency broad access to nuclear fuel-cycle related information and locations. TRP, in Tokai-mura, Ibaraki prefecture in Japan, was built in the early 1970s, using 1960s-era design and technology. The IAEA began inspecting the facility in 1977. In its annual evaluation of safeguards implementation, as reported to the IAEA's Board of Governors in the Safeguards Implementation Report, the Secretariat has regularly noted the need for strengthening safeguards implementation at TRP, particularly with respect to procedures used for the measurement of nuclear material in the waste produced. In 1996, Japan and the IAEA reached agreement on IAEA sampling, on a

  17. Using Data-Driven and Process Mining Techniques for Identifying and Characterizing Problem Gamblers in New Zealand

    Directory of Open Access Journals (Sweden)

    Suriadi Suriadi

    2016-12-01

    Full Text Available This article uses data-driven techniques combined with established theory in order to analyse gambling behavioural patterns of 91 thousand individuals on a real-world fixed-odds gambling dataset in New Zealand. This research uniquely integrates a mixture of process mining, data mining and confirmatory statistical techniques in order to categorise different sub-groups of gamblers, with the explicit motivation of identifying problem gambling behaviours and reporting on the challenges and lessons learned from our case study.We demonstrate how techniques from various disciplines can be combined in order to gain insight into the behavioural patterns exhibited by different types of gamblers, as well as provide assurances of the correctness of our approach and findings. A highlight of this case study is both the methodology which demonstrates how such a combination of techniques provides a rich set of effective tools to undertake an exploratory and open-ended data analysis project that is guided by the process cube concept, as well as the findings themselves which indicate that the contribution that problem gamblers make to the total volume, expenditure, and revenue is higher than previous studies have maintained.

  18. Signal Morphing techniques and possible application to Higgs properties measurements

    CERN Document Server

    Ecker, Katharina Maria; The ATLAS collaboration

    2016-01-01

    One way of describing deviations from the Standard Model is via Effective Field Theories or pseudo-observables, where higher order operators modify the couplings and the kinematics of the interaction of the Standard Model particles. Generating Monte Carlo events for every testable set of parameters for such a theory would require computing resources beyond the ones currently available in ATLAS. Up to now, Matrix-Element based reweighting techniques have been often used to model Beyond Standard Model process starting from Standard Model simulated events. In this talk, we review the advantages and the limitations of morphing techniques to construct continuous probability model for signal parameters, interpolating between a finite number of distributions obtained from the simulation chain. The technique will be exemplified by searching for deviations from the Standard Model predictions in Higgs properties measurements.

  19. Hydrogen clearance: Assessment of technique for measurement of skin-flap blood flow in pigs

    International Nuclear Information System (INIS)

    Thomson, J.G.; Kerrigan, C.L.

    1991-01-01

    The hydrogen clearance technique has been used for many years by investigators to determine brain blood flow and has been partially validated in this setting using other methods of blood flow measurement. The method has been modified to allow blood flow measurements in skin, but the accuracy of H2 clearance for measuring skin blood flow has not been determined. Multiple blood flow measurements were performed using H2 clearance and radioactive microspheres on skin flaps and control skin in pigs. On 12 pigs, a total of 117 flap and 42 control skin measurements were available for analysis. There was no significant difference between the two techniques in measuring mean control skin blood flow. In skin flaps, H2 clearance was significantly correlated to microsphere-measured blood flow, but it consistently gave an overestimate. Sources of error may include injury to the tissues by insertion of electrodes, consumption of H2 by the electrodes, or diffusion of H2 from the relatively ischemic flap to its well-vascularized bed. Further studies are necessary to determine the cause of this error and to measure the technique's accuracy in skeletal muscle and other flaps

  20. Proceedings of the symposium on advanced measurement techniques and instrumentation: abstract book

    International Nuclear Information System (INIS)

    Kale, Y.B.; Kushwaha, M.; Somkuwar, S.P.; Ajayakumar, S.; Sampathkumar, R.

    2011-01-01

    In order to consolidate the existing knowledge base and further to focus on the future directions of the field of advanced measurement techniques and instrumentation, Bhabha Atomic Research Centre has organized a three-day symposium on 'Advanced Measurement Techniques and Instrumentation' at Multi Purpose Hall, Training School Hostel, Anushaktinagar, Mumbai during February 02-04, 2011. The symposium is aimed at providing a forum to discuss the emerging trends and challenges ahead in the important area of measurement science and technology. This is a unique symposium, which brings together scientists and engineers from all disciplines and provides them a platform for close interaction to exchange ideas, methodologies and expertise, which is extremely important for synergic growth of this field. The symposium consists of 27 talks, which include keynote address, plenary and invited talks, and 63 contributory papers. The abstracts of these papers are brought to you in this volume. Readers may observe that the scientific programme of the symposium covers a wide ranging issues including advanced scientific concepts in measurements, instrumentation strategies, mathematical techniques and development of devices for applications in fundamental physics, astrophysics, fusion plasmas, nuclear reactors, accelerators, environment, chemical and biological sciences, and national security. Papers relevant to INIS are indexed separately

  1. Cost-effective ERT technique for oil-in-water measurement for offshore hydrocyclone installations

    DEFF Research Database (Denmark)

    Durdevic, Petar; Hansen, Leif; Mai, Christian

    2015-01-01

    The goal of this paper is to introduce and design a cost-effective Oil-in-Water (OiW) measuring instrument, which will be investigated for its value in increasing the efficiency of a deoiling hydrocyclone. The technique investigated is based on Electrical Resistivity Tomography (ERT), which basic...... principle is to measure the resistivity of substances from multiple electrodes and from these measurements create a 2-D image of the oil and gas component in the water. This technique requires the measured components to have different electrical resistances, such as seawater which has a lower electrical...... resistance than hydrocarbon oil and gas. This work involves construction of a pilot plant, for testing the feasibility of ERT for OiW measurements, and further exploring if this measured signal can be applied as a reliable feedback signal in optimization of the hydrocyclone's efficiency. Different algorithms...

  2. Cost-Effective ERT Technique for Oil-in-Water Measurement for Offshore Hydrocyclone Installations

    DEFF Research Database (Denmark)

    Løhndorf, Petar Durdevic; Hansen, Leif; Mai, Christian

    2015-01-01

    The goal of this paper is to introduce and design a cost-effective Oil-in-Water (OiW) measuring instrument, which will be investigated for its value in increasing the efficiency of a deoiling hydrocyclone. The technique investigated is based on Electrical Resistivity Tomography (ERT), which basic...... principle is to measure the resistivity of substances from multiple electrodes and from these measurements create a 2-D image of the oil and gas component in the water. This technique requires the measured components to have different electrical resistances, such as seawater which has a lower electrical...... resistance than hydrocarbon oil and gas. This work involves construction of a pilot plant, for testing the feasibility of ERT for OiW measurements, and further exploring if this measured signal can be applied as a reliable feedback signal in optimization of the hydrocyclone's efficiency. Different algorithms...

  3. Internal flow measurement in transonic compressor by PIV technique

    Science.gov (United States)

    Wang, Tongqing; Wu, Huaiyu; Liu, Yin

    2001-11-01

    The paper presents some research works conducted in National Key Laboratory of Aircraft Engine of China on the shock containing supersonic flow measurement as well as the internal flow measurement of transoijc compressor by PIC technique. A kind of oil particles in diameter about 0.3 micrometers containing in the flow was discovered to be a very good seed for the PIV measurement of supersonic jet flow. The PIV measurement in over-expanded supersonic free jet and in the flow over wages show a very clear shock wave structure. In the PIV internal flow measurement of transonic compressor a kind of liquid particle of glycol was successful to be used as the seed. An illumination periscope with sheet forming optics was designed and manufactured, it leaded the laser shot generated from an integrate dual- cavity Nd:YAG laser of TSI PIV results of internal flow of an advanced low aspect ratio transonic compressor were shown and discussed briefly.

  4. The use of environmental monitoring as a technique to identify isotopic enrichment activities; O uso da monitoracao ambiental como tecnica de identificacao de atividades de enriquecimento isotopico

    Energy Technology Data Exchange (ETDEWEB)

    Buchmann, Jose Henrique

    2000-07-01

    The use of environmental monitoring as a technique to identify activities related to the nuclear fuel cycle has been proposed, by international organizations, as an additional measure to the safeguards agreements in force. The elements specific for each kind of nuclear activity, or nuclear signatures, inserted in the ecosystem by several transfer paths, can be intercepted with better or worse ability by different live organisms. Depending on the kind of signature of interest, the anthropogenic material identification and quantification require the choice of adequate biologic indicators and, mainly, the use of sophisticated techniques associated with elaborate sample treatments. This work demonstrates the technical viability of using pine needles as bioindicators of nuclear signatures associated with uranium enrichment activities. Additionally, it proposes the use of a technique widely diffused nowadays in the scientific community, the High Resolution Inductively Coupled Plasma Mass Spectrometer (HR-ICP-MS), to identify the signature corresponding to that kind of activities in the ecosystem. It can be also found a description of a methodology recently being applied in analytical chemistry,based on uncertainties estimates metrological concepts, used to calculate the uncertainties associated with the obtained measurement results. Nitric acid solutions with a concentration of 0.3 mol.kg{sup -1}, used to wash pine needles sampled near facilities that manipulate enriched uranium and containing only 0.1 {mu}g.kg{sup -1} of uranium, exhibit a {sup 235} U: {sup 238} U isotopic abundance ratio of 0.0092{+-}0.0002, while solutions originated from samples collected at places located more than 200 km far from activities related to the nuclear fuel cycle exhibit a value of 0.0074{+-}0.0002 for this abundance ratio. Similar results were obtained for samples collected in different places permit to confirm the presence of anthropogenic uranium and demonstrate the viability of using

  5. Review of Micro/Nano Nondestructive Evaluation Technique (II): Measurement of Acoustic Properties

    International Nuclear Information System (INIS)

    Kim, Chung Seok; Park, Ik Keun

    2012-01-01

    The present paper reviews the micro and nano nondestructive evaluation(NDE) technique that is possible to investigate the surface and measure the acoustic properties. The technical theory, features and applications of the ultrasonic atomic force microscopy(UAFM) and scanning acoustic microscopy(SAM) are illustrated. Especially, these technologies are possible to evaluate the mechanical properties in micro/nano structure and surface through the measurement of acoustic properties in addition to the observation of surface and subsurface. Consequently, it is thought that technique developments and applications of these micro/nano NDE in advanced industrial parts together with present nondestructive industry are widely possible hereafter.

  6. The Recommendations for Linear Measurement Techniques on the Measurements of Nonlinear System Parameters of a Joint.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Scott A [Univ. of Maryland Baltimore County (UMBC), Baltimore, MD (United States); Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Catalfamo, Simone [Univ. of Stuttgart (Germany); Brake, Matthew R. W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rice Univ., Houston, TX (United States); Schwingshackl, Christoph W. [Imperial College, London (United Kingdom); Reusb, Pascal [Daimler AG, Stuttgart (Germany)

    2017-01-01

    In the study of the dynamics of nonlinear systems, experimental measurements often convolute the response of the nonlinearity of interest and the effects of the experimental setup. To reduce the influence of the experimental setup on the deduction of the parameters of the nonlinearity, the response of a mechanical joint is investigated under various experimental setups. These experiments first focus on quantifying how support structures and measurement techniques affect the natural frequency and damping of a linear system. The results indicate that support structures created from bungees have negligible influence on the system in terms of frequency and damping ratio variations. The study then focuses on the effects of the excitation technique on the response for a linear system. The findings suggest that thinner stingers should not be used, because under the high force requirements the stinger bending modes are excited adding unwanted torsional coupling. The optimal configuration for testing the linear system is then applied to a nonlinear system in order to assess the robustness of the test configuration. Finally, recommendations are made for conducting experiments on nonlinear systems using conventional/linear testing techniques.

  7. Development of a 2D temperature measurement technique for combustion diagnostics using 2-line atomic fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Engstroem, Johan

    2001-01-01

    The present thesis is concerned with the development and application of a novel planar laser-induced fluorescence (PLIF) technique for temperature measurements in a variety of combusting flows. Accurate measurement of temperature is an essential task in combustion diagnostics, since temperature is one of the most fundamental quantities for the characterization of combustion processes. The technique is based on two-line atomic fluorescence (TLAF) from small quantities of atomic indium (In) seeded into the fuel. It has been developed from small-scale experiments in laboratory flames to the point where practical combustion systems can be studied. The technique is conceptually simple and reveals temperature information in the post-flame regions. The viability of the technique has been tested in three extreme measurement situations: in spark ignition engine combustion, in ultra-lean combustion situations such as lean burning aero-engine concepts and, finally, in fuel-rich combustion. TLAF was successfully applied in an optical Sl engine using isooctane as fuel. The wide temperature sensitivity, 700 - 3000 K, of the technique using indium atoms allowed measurements over the entire combustion cycle in the engine to be performed. In applications in lean combustion a potential problem caused by the strong oxidation processes of indium atoms was encountered. This limits measurement times due to deposits of absorbing indium oxide on measurement windows. The seeding requirement is a disadvantage of the technique and can be a limitation in some applications. The results from experiments performed in sooting flames are very promising for thermometry measurements in such environments. Absorption by hydrocarbons and other native species was found to be negligible. Since low laser energies and low seeding concentrations could be used, the technique did not, unlike most other incoherent optical thermometry techniques, suffer interferences from LII of soot particles or LIF from PAH

  8. Magnetic moment measurement of 140Ba nuclei using transient field technique

    International Nuclear Information System (INIS)

    Saxena, Mansi; Mandal, S.; Siwal, Davinder; Rainovski, G.; Danchev, M.; Damyanova, A.; Gladnishki, K.; Leske, J.; Bauer, C.; Bloch, T.; John, P.; Pietralla, N.; Wollersheim, H.J.; Kojouharov, I.; Pietri, S.; Schaffner, H.

    2011-01-01

    Mixed symmetry states have been identified in the neutron proton version of the Interacting Boson Model. The motivation of this experiment is to identify uniquely one phonon mixed symmetry states in 140 Ba nuclei by g factor measurement of the states. Magnetic moments measurements provide substantial information on the microscopic structure of the nuclei as the magnetic moment of a nuclei is described by the wave function of one state only. In this present paper we report the preliminary results of the g factor measurement of the first 2 + state of 140 Ba

  9. Measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1976-08-01

    The purpose of this work has been an analysis and evaluation of the state-of-the-art of measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities. The occurrence of plutonium and uranium in the nuclear fuel cycle, the corresponding potential for releases, associated radiological protection standards and monitoring objectives are discussed. Techniques for monitoring via decay radiation from plutonium and uranium isotopes are presented in detail, emphasizing air monitoring, but also including soil sampling and survey methods. Additionally, activation and mass measurement techniques are discussed. The availability and prevalence of these various techniques are summarized. Finally, possible improvements in monitoring capabilities due to alterations in instrumentation, data analysis, or programs are presented

  10. Primary study on image addition technique in CT measuring used to determine the malalignment of patellofemoral joints

    International Nuclear Information System (INIS)

    Huan Jian; Gong Jianping; Zhu Jianbing; Dong Qirong; Lu Zhian

    2000-01-01

    Objective: To evaluate the use of image addition technique in the field of CT measuring on patellofemoral joints. Method: In contractive condition and relaxant condition of quadriceps, 60 knee joints of 30 patients (47 knee joints accompanied with peri-patellar pain) were examined by CT scanning, and the CT image addition and single technique. Results: In contractive and relaxant condition of quadriceps in the normal group, the difference between index measured by image addition technique were not significant and it was found that demonstrated measurement error of image addition was smaller, but there was significant difference between index measured by single technique, and it suggests that its replication was bad. Conclusion: Use of image addition technique can decrease measurement error and play a important role on accurately determining the malalignment of patellofemoral joints

  11. Microvascular imaging: techniques and opportunities for clinical physiological measurements

    International Nuclear Information System (INIS)

    Allen, John; Howell, Kevin

    2014-01-01

    The microvasculature presents a particular challenge in physiological measurement because the vessel structure is spatially inhomogeneous and perfusion can exhibit high variability over time. This review describes, with a clinical focus, the wide variety of methods now available for imaging of the microvasculature and their key applications. Laser Doppler perfusion imaging and laser speckle contrast imaging are established, commercially-available techniques for determining microvascular perfusion, with proven clinical utility for applications such as burn-depth assessment. Nailfold capillaroscopy is also commercially available, with significant published literature that supports its use for detecting microangiopathy secondary to specific connective tissue diseases in patients with Raynaud's phenomenon. Infrared thermography measures skin temperature and not perfusion directly, and it has only gained acceptance for some surgical and peripheral microvascular applications. Other emerging technologies including imaging photoplethysmography, optical coherence tomography, photoacoustic tomography, hyperspectral imaging, and tissue viability imaging are also described to show their potential as techniques that could become established tools for clinical microvascular assessment. Growing interest in the microcirculation has helped drive the rapid development in perfusion imaging of the microvessels, bringing exciting opportunities in microvascular research. (topical review)

  12. A Balloon Sounding Technique for Measuring SO2 Plumes

    Science.gov (United States)

    Morris, Gary A.; Komhyr, Walter D.; Hirokawa, Jun; Lefer, Barry; Krotkov, Nicholay; Ngan, Fong

    2010-01-01

    This paper reports on the development of a new technique for inexpensive measurements of SO2 profiles using a modified dual-ozonesonde instrument payload. The presence of SO2 interferes with the standard electrochemical cell (ECC) ozonesonde measurement, resulting in -1 molecule of O3 reported for each molecule of SO2 present (provided [O3] > [SO2]). In laboratory tests, an SO2 filter made with Cr03 placed on the inlet side of the sonde removes nearly 100% of the SO2 present for concentrations up to 60 ppbv and remained effective after exposure to 2.8 X 10(exp 16) molecules of SO2 [equivalent to a column approximately 150 DU (1 DU = 2.69 X 10(exp 20) molecules m(exp -2))]. Flying two ECC instruments on the same payload with one filtered and the other unfiltered yields SO2 profiles, inferred by subtraction. Laboratory tests and field experience suggest an SO2 detection limit of approximately 3 pbb with profiles valid from the surface to the ozonopause [i.e., approximately (8-10 km)]. Two example profiles demonstrate the success of this technique for both volcanic and industrial plumes.

  13. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  14. Developing and Implementing an Assessment Technique to Measure Linked Concepts

    Science.gov (United States)

    Ye, Li; Oueini, Razanne; Lewis, Scott E.

    2015-01-01

    The links students make among chemistry content is considered essential for a robust, enduring understanding in multiple learning theories. This article describes the development and implementation of an assessment technique, termed a Measure of Linked Concepts, designed to inform instructors on students' understanding of linking content…

  15. ACCENT-BIAFLUX workshop 2005, trace gas and aerosol flux measurement and techniques. Abstract book

    Energy Technology Data Exchange (ETDEWEB)

    Werner, A.; Soerensen, L.L. (eds.)

    2005-04-01

    The woorkshop trace gas and aerosol flux measurement techniques in the second meeting within the Biosphere Atmosphere Exchange of Pollutions (BIAFLUX) group in the EU-network project Atmospheric Composition Change (ACCENT). The goal of the workshop is to obtain an overview of techniques for measurements of gas and aerosol fluxes and to gather the knowledge of uncertainties in flux measurements and calculations. The workshop is funded by ACCENT. The abstract book presents abstracts of 21 oral presentations and 26 poster presentations. (LN)

  16. Strain measurement technique

    International Nuclear Information System (INIS)

    1987-01-01

    The 10 contributions are concerned with selected areas of application, such as strain measurements in wood, rubber/metal compounds, sets of strain measurements on buildings, reinforced concrete structures without gaps, pipes buried in the ground and measurements of pressure fluctuations. To increase the availability and safety of plant, stress analyses were made on gas turbine rotors with HT-DMS or capacitive HT-DMS (high temperature strain measurements). (DG) [de

  17. Kalman filtering techniques for reducing variance of digital speckle displacement measurement noise

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ Target dynamics are assumed to be known in measuring digital speckle displacement. Use is made of a simple measurement equation, where measurement noise represents the effect of disturbances introduced in measurement process. From these assumptions, Kalman filter can be designed to reduce variance of measurement noise. An optical and analysis system was set up, by which object motion with constant displacement and constant velocity is experimented with to verify validity of Kalman filtering techniques for reduction of measurement noise variance.

  18. Techniques for Ultra-high Magnetic Field Gradient NMR Diffusion Measurements

    Science.gov (United States)

    Sigmund, Eric E.; Mitrovic, Vesna F.; Calder, Edward S.; Will Thomas, G.; Halperin, William P.; Reyes, Arneil P.; Kuhns, Philip L.; Moulton, William G.

    2001-03-01

    We report on development and application of techniques for ultraslow diffusion coefficient measurements through nuclear magnetic resonance (NMR) in high magnetic field gradients. We have performed NMR experiments in a steady fringe field gradient of 175 T/m from a 23 T resistive Bitter magnet, as well as in a gradient of 42 T/m from an 8 T superconducting magnet. New techniques to provide optimum sensitivity in these experiments are described. To eliminate parasitic effects of the temporal instability of the resistive magnet, we have introduced a passive filter: a highly conductive cryogen-cooled inductive shield. We show experimental demonstration of such a shield’s effect on NMR performed in the Bitter magnet. For enhanced efficiency, we have employed “frequency jumping” in our spectrometer system. Application of these methods has made possible measurements of diffusion coefficients as low as 10-10 cm^2/s, probing motion on a 250 nm length scale.

  19. Measurement of the buccolingual inclination of teeth: manual technique vs 3-dimensional software.

    Science.gov (United States)

    Nouri, Mahtab; Abdi, Amir Hossein; Farzan, Arash; Mokhtarpour, Faraneh; Baghban, AliReza Akbarzadeh

    2014-10-01

    In this study, we aimed to measure the inclination of teeth on dental casts by a manual technique with the tooth inclination protractor (TIP; MBI, Newport, United Kingdom) and a newly designed 3-dimensional (3D) software program. The correlation of the 2 techniques was evaluated, and the reliability of each technique was assessed separately. This study was conducted on 36 dental casts of normal, well-aligned Class I occlusions; we assessed 432 teeth. All casts had a normal Class I occlusion. After determining the facial axis of the clinical crown and the facial axis points on the dental casts, we measured the inclinations of the incisors and posterior teeth up to the first molars in each dental arch relative to Andrews' occlusal plane and the posterior occlusal plane using the TIP. Moreover, the casts were scanned by a structured-light 3D scanner. The inclination of teeth relative to the occlusal plane was determined using the new software. To assess the reliability, measurements of all teeth from 15 casts were repeated twice by the 2 methods. Intraclass correlation coefficient and Dahlberg's formula were used for calculation of correlation and reliability. Overall, the 2 techniques were not significantly different in the measurements of the inclinations of the teeth in both jaws. The ranges of Dahlberg's formula were 3.1° to 5.8° for the maxilla and 3.3° to 5.9° for the mandible. The overall correlation of the 2 techniques according to the intraclass correlation coefficient was 0.91. For calculation of reliability, the intraclass correlation coefficients for the TIP and the 3D method were 0.73 and 0.82, respectively. The TIP and the 3D software showed a high correlation for measurement of the inclinations of maxillary and mandibular teeth relative to the occlusal plane. Also, the reproducibility of the measurements in each method was high. Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  20. Stable isotope measurement techniques for atmospheric greenhouse gases

    International Nuclear Information System (INIS)

    2002-01-01

    The technical requirements to perform useful measurements of atmospheric greenhouse gas concentrations and of their isotope ratios are of direct relevance for all laboratories engaged in this field. A meaningful interpretation of isotopes in global models on sources and sinks of CO 2 and other greenhouse gases depends on strict laboratory protocols and data quality control measures ensuring comparable data in time and space. Only with this precondition met, the isotope techniques can serve as a potentially powerful method for reducing uncertainties in the global CO 2 budgets and for tracing pathways and interaction of terrestrial, oceanic, and atmospheric pools of carbon. This publication provides four contributions describing methods for the determination of the isotopic composition of trace gases in atmospheric air and in ice cores. These contributions have been indexed separately

  1. Perceived Effectiveness of Identified Methods and Techniques Teachers Adopt in Prose Literature Lessons in some Secondary Schools in Owerri

    Directory of Open Access Journals (Sweden)

    F. O. Ezeokoli

    2016-07-01

    Full Text Available The study determined the methods adopted by teachers in prose literature-in-English classrooms, activities of teachers and students, teachers’ perceived effectiveness of techniques used. It also examined the objectives of teaching prose literature that teachers should address and the extent teachers believe in student-identified difficulties of studying prose literature. The study adopted the descriptive survey research design. Purposive sampling technique was used to select 85 schools in Owerri metropolis and in each school, all literature teachers of senior secondary I and II were involved. In all, 246 literature teachers participated out of which 15 were purposively selected for observation. The two instruments were: Teachers’ Questionnaire (r = 0.87 and Classroom Observation Schedule (r = 0.73. Data were analysed using frequency counts and percentages. Results revealed that teachers adopted lecture (28.4%, reading (10.9% and discussion (7.3% methods. Teacher’s activities during the lesson include: giving background information, summarizing, dictating notes, reading aloud and explaining and asking questions. The adopted techniques include: questioning, oral reading, silent reading and discussion. Teachers’ perceived questioning as the most effective technique followed by debating and summarizing. Teachers identified development of students’ critical faculties and analytical skills, literary appreciation and language skills to be of utmost concern. It was concluded that the methods adopted by teachers are not diverse enough to cater for the needs and backgrounds of students. Keywords: Methods, Techniques, Perceived Effectiveness, Objectives, Literature-in-English

  2. Ultra-small time-delay estimation via a weak measurement technique with post-selection

    International Nuclear Information System (INIS)

    Fang, Chen; Huang, Jing-Zheng; Yu, Yang; Li, Qinzheng; Zeng, Guihua

    2016-01-01

    Weak measurement is a novel technique for parameter estimation with higher precision. In this paper we develop a general theory for the parameter estimation based on a weak measurement technique with arbitrary post-selection. The weak-value amplification model and the joint weak measurement model are two special cases in our theory. Applying the developed theory, time-delay estimation is investigated in both theory and experiments. The experimental results show that when the time delay is ultra-small, the joint weak measurement scheme outperforms the weak-value amplification scheme, and is robust against not only misalignment errors but also the wavelength dependence of the optical components. These results are consistent with theoretical predictions that have not been previously verified by any experiment. (paper)

  3. Adhesive polypeptides of Staphylococcus aureus identified using a novel secretion library technique in Escherichia coli

    Directory of Open Access Journals (Sweden)

    Holm Liisa

    2011-05-01

    Full Text Available Abstract Background Bacterial adhesive proteins, called adhesins, are frequently the decisive factor in initiation of a bacterial infection. Characterization of such molecules is crucial for the understanding of bacterial pathogenesis, design of vaccines and development of antibacterial drugs. Because adhesins are frequently difficult to express, their characterization has often been hampered. Alternative expression methods developed for the analysis of adhesins, e.g. surface display techniques, suffer from various drawbacks and reports on high-level extracellular secretion of heterologous proteins in Gram-negative bacteria are scarce. These expression techniques are currently a field of active research. The purpose of the current study was to construct a convenient, new technique for identification of unknown bacterial adhesive polypeptides directly from the growth medium of the Escherichia coli host and to identify novel proteinaceous adhesins of the model organism Staphylococcus aureus. Results Randomly fragmented chromosomal DNA of S. aureus was cloned into a unique restriction site of our expression vector, which facilitates secretion of foreign FLAG-tagged polypeptides into the growth medium of E. coli ΔfliCΔfliD, to generate a library of 1663 clones expressing FLAG-tagged polypeptides. Sequence and bioinformatics analyses showed that in our example, the library covered approximately 32% of the S. aureus proteome. Polypeptides from the growth medium of the library clones were screened for binding to a selection of S. aureus target molecules and adhesive fragments of known staphylococcal adhesins (e.g coagulase and fibronectin-binding protein A as well as polypeptides of novel function (e.g. a universal stress protein and phosphoribosylamino-imidazole carboxylase ATPase subunit were detected. The results were further validated using purified His-tagged recombinant proteins of the corresponding fragments in enzyme-linked immunoassay and

  4. A New Technique to Identify Arbitrarily Shaped Noise Sources

    Directory of Open Access Journals (Sweden)

    Roberto A. Tenenbaum

    2006-01-01

    Full Text Available Acoustic intensity is one of the available tools for evaluating sound radiation from vibrating bodies. Active intensity may, in some situations, not give a faithful insight about how much energy is in fact carried into the far field. It was then proposed a new parameter, the supersonic acoustic intensity, which takes into account only the intensity generated by components having a smaller wavenumber than the acoustic one. However, the method is only efective for simple sources, such as plane plates, cylinders and spheres. This work presents a new technique, based on the Boundary Elements Method and the Singular Value Decomposition, to compute the supersonic acoustic intensity for arbitrarily shaped sources. The technique is based in the Kirchoff-Helmholtz equation in a discretized approach, leading to a radiation operator that relates the normal velocity on the source's surface mesh with the pressure at grid points located in the field. Then, the singular value decomposition technique is set to the radiation operator and a cutoff criterion is applied to remove non propagating components. Some numerical examples are presented.

  5. Techniques for sampling nuclear waste tank contents and in situ measurement of activity

    International Nuclear Information System (INIS)

    Lawrence, R.C.

    1978-04-01

    A study was conducted to develop suitable sampling equipment and techniques for characterizing the mechanical properties of nuclear wastes; identifying effective means of measuring radiation levels, temperatures, and neutron fluxes in situ in wastes; and developing a waste core sampler. A portable, stainless steel probe was developed which is placed in the tank through a riser. This probe is built for the insertion of instrumentation that can measure the contents of the tank at any level and take temperature, radiation, and neutron activation readings with reliable accuracy. A simple and reliable instrument for the in situ extraction of waste materials ranging from liquid to concrete-like substances was also developed. This portable, stainless steel waste core sampler can remove up to one liter of radioactive waste from tanks for transportation to hot cell laboratories for analysis of hardness, chemical form, and isotopic content. A cask for transporting the waste samples from the tanks to the laboratory under radiation-protected conditions was also fabricated. This cask was designed with a ''boot'' or inner-seal liner to contain any radioactive wastes that might remain on the outside of the waste core sampling device

  6. Primary flow and temperature measurements in PWRS using non-invasive techniques

    International Nuclear Information System (INIS)

    Favennec, J.M.; Jossinet, G.; Thomas, P.

    1995-08-01

    PWR primary flow and temperature measurements are classically done with either indirect or invasive techniques. EDF has developed and installed non-invasive innovative techniques on an industrial nuclear power plant (Chooz N1 type PWR). Primary flow-rate is determined by measurement of velocity of primary water in the hot leg: the time fluctuation of γ-ray activity from Nitrogen-16 (produced by neutron activation of 016) is measured outside of the pipe by two specially-designed detectors. The signals from both detectors are then cross-correlated to determine the transit time of primary water between the two detectors; primary flow-rate is then deduced Primary temperature is determined by measurement of sound velocity in hot and cold leg: two pairs of ultrasonic transducers, installed on pipe outer wall, emit pulses periodically, for which the time of flight along the two pipes diameters are determined. The sound velocity thus computed (diameter over time of flight) is then converted into temperature, by use of a calibration formula relating sound velocity to temperature and pressure. This paper addresses metrological and technical aspects of the methods. Experience feedback on industrial PWRs is also presented. (author). 4 refs., 13 figs

  7. Measurement and image processing evaluation of surface modifications of dental implants G4 pure titanium created by different techniques

    Energy Technology Data Exchange (ETDEWEB)

    Bulutsuz, A. G., E-mail: asligunaya@gmail.com [Department of Mechanical Engineering, Yildiz Technical University, 34349 Besiktas, İstanbul (Turkey); Demircioglu, P., E-mail: pinar.demircioglu@adu.edu.tr; Bogrekci, I., E-mail: ismail.bogrekci@adu.edu.tr [Adnan Menderes University, Faculty of Engineering, Department of Mechanical Engineering, Aytepe, 09010, Aydin (Turkey); Durakbasa, M. N., E-mail: durakbasa@gmx.at [Department of Interchangeable Manufacturing and Industrial Metrology, Institute for Production Engineering and Laser Technology, Vienna University of Technology, Karlsplatz 13/3113 A-1040 Wien (Austria); Katiboglu, A. B., E-mail: abkatiboglu@hotmail.com [Istanbul University, Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Istanbul (Turkey)

    2015-03-30

    Foreign substances and organic tissue interaction placed into the jaw in order to eliminate tooth loss involves a highly complex process. Many biological reactions take place as well as the biomechanical forces that influence this formation. Osseointegration denotes to the direct structural and functional association between the living bone and the load-bearing artificial implant's surface. Taking into consideration of the requirements in the manufacturing processes of the implants, surface characterizations with high precise measurement techniques are investigated and thus long-term success of dental implant is emphasized on the importance of these processes in this study. In this research, the detailed surface characterization was performed to identify the dependence of the manufacturing techniques on the surface properties by using the image processing methods and using the scanning electron microscope (SEM) for morphological properties in 3D and Taylor Hobson stylus profilometer for roughness properties in 2D. Three implant surfaces fabricated by different manufacturing techniques were inspected, and a machined surface was included into the study as a reference specimen. The results indicated that different surface treatments were strongly influenced surface morphology. Thus 2D and 3D precise inspection techniques were highlighted on the importance for surface characterization. Different image analyses techniques such as Dark-light technique were used to verify the surface measurement results. The computational phase was performed using image processing toolbox in Matlab with precise evaluation of the roughness for the implant surfaces. The relationship between the number of black and white pixels and surface roughness is presented. FFT image processing and analyses results explicitly imply that the technique is useful in the determination of surface roughness. The results showed that the number of black pixels in the image increases with increase in

  8. Fast sorting measurement technique to determine decontamination priority

    International Nuclear Information System (INIS)

    Distenfeld, C.H.; Brosey, B.; Igarashi, H.

    1986-01-01

    The method used to select decontamination priorities for the Three Mile Island Unit 2 (TMI-2) reactor building (RB) is systematic, but costs in personnel exposure and time must be borne. One way of minimizing exposure is to define and treat the one or two surface sources that are important contributors to the collective dose of the recovery personnel. Surface characteristics can then be determined and decontamination techniques developed to match the removal requirements. At TMI-2, a fast sorting technique was developed and used to prioritize surfaces for exposure reduction. A second quick sort can then be used to determine the next generation of surface characterization, decontamination method selection, and performance. The quick-sort method that was developed is based on the Eberline HP 220A probes directional survey system. The angular response of the HP 220A probes approaches 2 pi steradians and allows toward-away type measurements. Sources distributed over 4 pi steradians are hard to define with this system. Angular differentiation was improved to about pi/2 steradians by redesigning the probe shield. The change allows unambiguous six-direction measurements, such as up, down, front, rear, right, and left with practically no angular overlap or exclusion. A simple, light-weight stand was used to establish an angular reference for the rectangular packaged probe. The six surface planes of the rectangle work with the angular reference to establish the six viewing angles

  9. Measurement of the amplitude and phase transfer functions of an optical modulator using a heterodyne technique

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2001-01-01

    We present a new technique that measures the full amplitude and phase transfer curves of the modulator as a function of the applied bias, from which the small signal α-parameter can be calculated. The technique measures the amplitude and phase transfer functions simultaneously and directly......, compared to techniques where a time-consuming data analysis is necessary to calculate the a-parameter and an additional measurement is necessary to estimate the phase. Additionally, the chirp profile for all operation points can be calculated....

  10. Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques

    Science.gov (United States)

    Yoon, Jihyung; Heins, David; Zhao, Xiaodong; Sanders, Mary; Zhang, Rui

    2017-12-01

    More and more advanced radiotherapy techniques have been adopted for post-mastectomy radiotherapies (PMRT). Patient dose reconstruction is challenging for these advanced techniques because they increase the low out-of-field dose area while the accuracy of out-of-field dose calculations by current commercial treatment planning systems (TPSs) is poor. We aim to measure and model the out-of-field radiation doses from various advanced PMRT techniques. PMRT treatment plans for an anthropomorphic phantom were generated, including volumetric modulated arc therapy with standard and flattening-filter-free photon beams, mixed beam therapy, 4-field intensity modulated radiation therapy (IMRT), and tomotherapy. We measured doses in the phantom where the TPS calculated doses were lower than 5% of the prescription dose using thermoluminescent dosimeters (TLD). The TLD measurements were corrected by two additional energy correction factors, namely out-of-beam out-of-field (OBOF) correction factor K OBOF and in-beam out-of-field (IBOF) correction factor K IBOF, which were determined by separate measurements using an ion chamber and TLD. A simple analytical model was developed to predict out-of-field dose as a function of distance from the field edge for each PMRT technique. The root mean square discrepancies between measured and calculated out-of-field doses were within 0.66 cGy Gy-1 for all techniques. The IBOF doses were highly scattered and should be evaluated case by case. One can easily combine the measured out-of-field dose here with the in-field dose calculated by the local TPS to reconstruct organ doses for a specific PMRT patient if the same treatment apparatus and technique were used.

  11. The non-contact biometric identified bio signal measurement sensor and algorithms.

    Science.gov (United States)

    Kim, Chan-Il; Lee, Jong-Ha

    2018-04-25

    In these days, wearable devices have been developed for effectively measuring biological data. However, these devices have tissue allege and noise problem. To solve these problems, biometric measurement based on a non-contact method, such as face image sequencing is developed. This makes it possible to measure biometric data without any operation and side effects. However, it is impossible for a remote center to identify the person whose data are measured by the novel methods. In this paper, we propose the novel non-contact heart rate and blood pressure imaging system, Deep Health Eye. This system has authentication process at the same time as measuring bio signals, through non-contact method. In the future, this system can be convenient home bio signal monitoring system by combined with smart mirror.

  12. A technique using a stellar spectrographic plate to measure terrestrial ozone column depth

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Alec Y. [Univ. of California, Berkeley, CA (United States)

    1995-08-01

    This thesis examines the feasibility of a technique to extract ozone column depths from photographic stellar spectra in the 5000--7000 Angstrom spectral region. A stellar spectrographic plate is measured to yield the relative intensity distribution of a star`s radiation after transmission through the earth`s atmosphere. The amount of stellar radiation absorbed by the ozone Chappuis band is proportional to the ozone column depth. The measured column depth is within 10% the mean monthly value for latitude 36{degree}N, however the uncertainty is too large to make the measurement useful. This thesis shows that a 10% improvement to the photographic sensitivity uncertainty can decrease the column depth uncertainty to a level acceptable for climatic study use. This technique offers the possibility of measuring past ozone column depths.

  13. An offset tone based gain stabilization technique for mixed-signal RF measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Gopal, E-mail: gjos@barc.gov.in [BARC, Mumbai 400085 (India); Motiwala, Paresh D.; Randale, G.D.; Singh, Pitamber [BARC, Mumbai 400085 (India); Agarwal, Vivek; Kumar, Girish [IIT Bombay, Powai, Mumbai 400076 (India)

    2015-09-21

    This paper describes a gain stabilization technique for a RF signal measurement system. A sinusoidal signal of known amplitude, phase and close enough in frequency is added to the main, to be measured RF signal at the input of the analog section. The system stabilizes this offset tone in the digital domain, as it is sampled at the output of the analog section. This process generates a correction factor needed to stabilize the magnitude of the gain of the analog section for the main RF signal. With the help of a simple calibration procedure, the absolute amplitude of the main RF signal can be measured. The technique is especially suited for a system that processes signals around a single frequency, employs direct signal conversion into the digital domain, and processes subsequent steps in an FPGA. The inherent parallel signal processing in an FPGA-based implementation allows a real time stabilization of the gain. The effectiveness of the technique is derived from the fact, that the gain stabilization stamped to the main RF signal measurement branch requires only a few components in the system to be inherently stable. A test setup, along with experimental results is presented from the field of RF instrumentation for particle accelerators. Due to the availability of a phase synchronized RF reference signal in these systems, the measured phase difference between the main RF and the RF reference is also stabilized using this technique. A scheme of the signal processing is presented, where a moving average filter has been used to filter out not only the unwanted frequencies, but also to separate the main RF signal from the offset tone signal. This is achieved by a suitable choice of sampling and offset tone frequencies. The presented signal processing scheme is suitable to a variety of RF measurement applications.

  14. Experimental comparison of particle interaction measurement techniques using optical traps

    International Nuclear Information System (INIS)

    Koehler, Timothy P.; Grillet, Anne Mary; Brotherton, Christopher M.; Molecke, Ryan A.

    2008-01-01

    Optical tweezers has become a powerful and common tool for sensitive determination of electrostatic interactions between colloidal particles. Recently, two techniques, 'blinking' tweezers and direct force measurements, have become increasingly prevalent in investigations of inter-particle potentials. The 'blinking' tweezers method acquires physical statistics of particle trajectories to determine drift velocities, diffusion coefficients, and ultimately colloidal forces as a function of the center-center separation of two particles. Direct force measurements monitor the position of a particle relative to the center of an optical trap as the separation distance between two continuously trapped particles is gradually decreased. As the particles near each other, the displacement from the trap center for each particle increases proportional to the inter-particle force. Although commonly employed in the investigation of interactions of colloidal particles, there exists no direct comparison of these experimental methods in the literature. In this study, an experimental apparatus was developed capable of performing both methods and is used to quantify electrostatic potentials between particles in several particle/solvent systems. Comparisons are drawn between the experiments conducted using the two measurement techniques, theory, and existing literature. Forces are quantified on the femto-Newton scale and results agree well with literature values

  15. REVIEW ARTICLE: Emission measurement techniques for advanced powertrains

    Science.gov (United States)

    Adachi, Masayuki

    2000-10-01

    Recent developments in high-efficiency low-emission powertrains require the emission measurement technologies to be able to detect regulated and unregulated compounds with very high sensitivity and a fast response. For example, levels of a variety of nitrogen compounds and sulphur compounds should be analysed in real time in order to develop aftertreatment systems to decrease emission of NOx for the lean burning powertrains. Also, real-time information on the emission of particulate matter for the transient operation of diesel engines and direct injection gasoline engines is invaluable. The present paper reviews newly introduced instrumentation for such emission measurement that is demanded for the developments in advanced powertrain systems. They include Fourier transform infrared spectroscopy, mass spectrometry and fast response flame ionization detection. In addition, demands and applications of the fuel reformer developments for fuel cell electric vehicles are discussed. Besides the detection methodologies, sample handling techniques for the measurement of concentrations emitted from low emission vehicles for which the concentrations of the pollutants are significantly lower than the concentrations present in ambient air, are also described.

  16. Application of the can technique and radon gas analyzer for radon exhalation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I.; Musazay, M.S.; Abu-Jarad, F

    2003-12-01

    A passive 'can technique' and an active radon gas analyzer with an emanation container were applied for radon exhalation rate measurements from different construction materials, viz. five marble seven ceramic and 100 granite tiles used in Saudi Arabia. The marble and ceramic tiles did not show detectable radon exhalation using the active radon gas analyzer system. However the granite tiles showed relatively high radon exhalations, indicating a relatively high uranium content. A comparison of the radon exhalation rates measured by the two techniques showed a linear correlation coefficient of 0.57. The radon exhalation rates from the granites varied from 0.02 to 6.58 Bq m{sup -2} h{sup -1} with an average of 1.35{+-}1.40 Bq m{sup -2} h{sup -1}. The geometric mean and the geometric standard deviation of the frequency distribution were found to be 0.80 and 3.1, respectively. The track density found on the nuclear track detectors in the can technique exposed to the granites, having high exhalation rates, varied linearly with exposure time with a linear correlation coefficient of 0.99. This experimental finding agrees with the theoretical prediction. The can technique showed sensitivity to low radon exhalation rates from ceramic, marble and some granite over a period of 2 months, which were not detectable by the active radon gas analyzer system. The reproducibility of data with both measuring techniques was found to be within a 7% deviation.

  17. Identifying fly puparia by clearing technique: application to forensic entomology.

    Science.gov (United States)

    Sukontason, Kabkaew L; Ngern-Klun, Radchadawan; Sripakdee, Duanghatai; Sukontason, Kom

    2007-10-01

    In forensic investigations, immature stages of the fly (egg, larva, or puparia) can be used as entomological evidence at death scenes, not only to estimate the postmortem interval (PMI), analyze toxic substances, and to determine the manner of death but also to indicate the movement of a corpse in homicide cases. Of these immature stages, puparia represent the longest developmental time, which makes them of useful. However, in order for forensic entomologists to use puparia effectively, it is crucial that they are able to accurately identify the species of fly found in a corpse. Typically, these puparia are similar in general appearance, being coarctate and light brown to dark brown in color, which makes identification difficult. In this study, we report on the clearing technique used to pale the integument of fly puparia, thereby allowing observation of the anterior end (second to fourth segments) and the profile of the posterior spiracle, which are important clues for identification. We used puparia of the blowfly, Chrysomya megacephala (F.), as the model species in this experiment. With placement in a 20% potassium hydroxide solution daily and mounting on a clearing medium (Permount(R), New Jersey), the profile of the posterior spiracle could be clearly examined under a light microscope beginning on the fifth day after pupation, and the number of papillae in the anterior spiracle could be counted easily starting from the ninth day. Comparison of morphological features of C. megacephala puparia with those of other blowflies (Chrysomya nigripes [Aubertin], Chrysomya rufifacies [Macquart], Chrysomya villeneuvi [Patton], Lucilia cuprina [Wiedemann], and Hemipyrellia ligurriens [Wiedemann]) and a housefly (Musca domestica L.) revealed that the anterior ends and the profiles of the posterior spiracles had markedly distinguishing characteristics. Morphometric analysis of the length and width of puparia, along with the length of the gaps between the posterior spiracles

  18. Nominal group technique: a brainstorming tool for identifying areas to improve pain management in hospitalized patients.

    Science.gov (United States)

    Peña, Adolfo; Estrada, Carlos A; Soniat, Debbie; Taylor, Benjamin; Burton, Michael

    2012-01-01

    Pain management in hospitalized patients remains a priority area for improvement; effective strategies for consensus development are needed to prioritize interventions. To identify challenges, barriers, and perspectives of healthcare providers in managing pain among hospitalized patients. Qualitative and quantitative group consensus using a brainstorming technique for quality improvement-the nominal group technique (NGT). One medical, 1 medical-surgical, and 1 surgical hospital unit at a large academic medical center. Nurses, resident physicians, patient care technicians, and unit clerks. Responses and ranking to the NGT question: "What causes uncontrolled pain in your unit?" Twenty-seven health workers generated a total of 94 ideas. The ideas perceived contributing to a suboptimal pain control were grouped as system factors (timeliness, n = 18 ideas; communication, n = 11; pain assessment, n = 8), human factors (knowledge and experience, n = 16; provider bias, n = 8; patient factors, n = 19), and interface of system and human factors (standardization, n = 14). Knowledge, timeliness, provider bias, and patient factors were the top ranked themes. Knowledge and timeliness are considered main priorities to improve pain control. NGT is an efficient tool for identifying general and context-specific priority areas for quality improvement; teams of healthcare providers should consider using NGT to address their own challenges and barriers. Copyright © 2011 Society of Hospital Medicine.

  19. An improved technique for non-destructive measurement of the stem ...

    African Journals Online (AJOL)

    It was concluded that the standard volume model based on the non-destructive measurement technique meets the requirements for precision in forest surveys. The precision of the standard volume model for L. gmelinii (a coniferous tree) was superior to that of the model for P. tomentosa (a broad-leaved tree). The electronic ...

  20. Flow-rate measurements in closed-conduits by tracer techniques

    International Nuclear Information System (INIS)

    Lund Plantat, C.

    1982-01-01

    This paper presents the study of the precision obtained measuring flow-rates in closed-conduits by tracer techniques. The flow-rates analyzed were in the range of 10 to 20 l/s and Reynolds numbers from 10 5 to 2 x 10 5 . Tracer used were fluoresceine and In-113 m; and the measurements were performed with the dilution method (punctual and continuous injection) and the Allen method. Precisions for the method of punctual and continuous injections were 6.25% and 9.45% for fluoresceine and 9.3% and 3% for In-113, respectively. For Allen method with In-113 m a precision of 5% was obtained; probably this value was affected by the short distance between detectors. In all cases the error corresponds with the expected value except in one measurement at a 68.3% confidence level. (I.V.)

  1. Digital instantaneous frequency measurement technique utilising high-speed ADC’s and FPGA’s

    CSIR Research Space (South Africa)

    Herselman, PL

    2006-02-27

    Full Text Available This paper presents the Digital Instantaneous Frequency Measurement (DIFM) technique, which can measure the carrier frequency of a received waveform within a fraction of a microsecond. The resulting frequency range, resolution and accuracy...

  2. Thickness measurement for the different metals by using Cs-137 gamma source with gamma transmission technique

    International Nuclear Information System (INIS)

    Bueyuek, B.; Tugrul, B.

    2009-01-01

    The purpose of this study is an experimental analysis of thickness measurement for various metals with the gamma transmission technique using Cs-137 as the radioisotope source. Lead, steel, brass, and aluminum, which are frequently used metals in industry, were chosen for the experiments. As the radioisotope source Cs-137 was preferred for the study since it has long half-life, it is mono energetic, and it penetrates the metals that were studied. Experiments were observed in the constant experimental geometry. Calibration curves for the four metal samples were plotted using the obtained results. To test the plotted calibration curves, counts for determining thickness measurement were collected for each sample and the obtained relative count values were used in conjunction with the plotted calibration curves for each sample to determine its thickness. The thicknesses of the samples have been measured with a micrometer and the results were comparatively analyzed with the measurement results obtained by the gamma transmission technique. The results of the analyses revealed that the thickness measurement values obtained with the gamma transmission technique and the thickness measurement values obtained with the conventional technique significantly converge to each other and the difference between the two values is at an acceptable level. Therefore the reliability of thickness measurements with the gamma transmission technique and the resulting calibration curves have been demonstrated.

  3. 3D interferometric shape measurement technique using coherent fiber bundles

    Science.gov (United States)

    Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen

    2017-06-01

    In-situ 3-D shape measurements with submicron shape uncertainty of fast rotating objects in a cutting lathe are expected, which can be achieved by simultaneous distance and velocity measurements. Conventional tactile methods, coordinate measurement machines, only support ex-situ measurements. Optical measurement techniques such as triangulation and conoscopic holography offer only the distance, so that the absolute diameter cannot be retrieved directly. In comparison, laser Doppler distance sensors (P-LDD sensor) enable simultaneous and in-situ distance and velocity measurements for monitoring the cutting process in a lathe. In order to achieve shape measurement uncertainties below 1 μm, a P-LDD sensor with a dual camera based scattered light detection has been investigated. Coherent fiber bundles (CFB) are employed to forward the scattered light towards cameras. This enables a compact and passive sensor head in the future. Compared with a photo detector based sensor, the dual camera based sensor allows to decrease the measurement uncertainty by the order of one magnitude. As a result, the total shape uncertainty of absolute 3-D shape measurements can be reduced to about 100 nm.

  4. A systematic literature search to identify performance measure outcomes used in clinical studies of racehorses.

    Science.gov (United States)

    Wylie, C E; Newton, J R

    2018-05-01

    Racing performance is often used as a measurable outcome variable in research studies investigating clinical diagnoses or interventions. However, the use of many different performance measures largely precludes conduct of meaningful comparative studies and, to date, those being used have not been collated. To systematically review the veterinary scientific literature for the use of racing performance as a measurable outcome variable in clinical studies of racehorses, collate and identify those most popular, and identify their advantages and disadvantages. Systematic literature search. The search criteria "((racing AND performance) AND (horses OR equidae))" were adapted for both MEDLINE and CAB Abstracts databases. Data were collected in standardised recording forms for binary, categorical and quantitative measures, and the use of performance indices. In total, 217 studies that described racing performance were identified, contributing 117 different performance measures. No one performance measure was used in all studies, despite 90.3% using more than one variable. Data regarding race starts and earnings were used most commonly, with 88.0% and 54.4% of studies including at least one measure of starts and earnings, respectively. Seventeen variables were used 10 times or more, with the top five comprising: 'return to racing', 'number of starts', 'days to first start', 'earnings per period of time' and 'earnings per start'. The search strategies may not have identified all relevant papers, introducing bias to the review. Performance indices have been developed to improve assessment of interventions; however, they are not widely adopted in the scientific literature. Use of the two most commonly identified measures, whether the horse returned to racing and number of starts over a defined period of time, would best facilitate future systematic reviews and meta-analyses in advance of the development of a gold-standard measure of race performance outcome. © 2017 EVJ Ltd.

  5. Equilibrium gas-oil ratio measurements using a microfluidic technique.

    Science.gov (United States)

    Fisher, Robert; Shah, Mohammad Khalid; Eskin, Dmitry; Schmidt, Kurt; Singh, Anil; Molla, Shahnawaz; Mostowfi, Farshid

    2013-07-07

    A method for measuring the equilibrium GOR (gas-oil ratio) of reservoir fluids using microfluidic technology is developed. Live crude oils (crude oil with dissolved gas) are injected into a long serpentine microchannel at reservoir pressure. The fluid forms a segmented flow as it travels through the channel. Gas and liquid phases are produced from the exit port of the channel that is maintained at atmospheric conditions. The process is analogous to the production of crude oil from a formation. By using compositional analysis and thermodynamic principles of hydrocarbon fluids, we show excellent equilibrium between the produced gas and liquid phases is achieved. The GOR of a reservoir fluid is a key parameter in determining the equation of state of a crude oil. Equations of state that are commonly used in petroleum engineering and reservoir simulations describe the phase behaviour of a fluid at equilibrium state. Therefore, to accurately determine the coefficients of an equation of state, the produced gas and liquid phases have to be as close to the thermodynamic equilibrium as possible. In the examples presented here, the GORs measured with the microfluidic technique agreed with GOR values obtained from conventional methods. Furthermore, when compared to conventional methods, the microfluidic technique was simpler to perform, required less equipment, and yielded better repeatability.

  6. Identifying desertification risk areas using fuzzy membership and geospatial technique - A case study, Kota District, Rajasthan

    Science.gov (United States)

    Dasgupta, Arunima; Sastry, K. L. N.; Dhinwa, P. S.; Rathore, V. S.; Nathawat, M. S.

    2013-08-01

    Desertification risk assessment is important in order to take proper measures for its prevention. Present research intends to identify the areas under risk of desertification along with their severity in terms of degradation in natural parameters. An integrated model with fuzzy membership analysis, fuzzy rule-based inference system and geospatial techniques was adopted, including five specific natural parameters namely slope, soil pH, soil depth, soil texture and NDVI. Individual parameters were classified according to their deviation from mean. Membership of each individual values to be in a certain class was derived using the normal probability density function of that class. Thus if a single class of a single parameter is with mean μ and standard deviation σ, the values falling beyond μ + 2 σ and μ - 2 σ are not representing that class, but a transitional zone between two subsequent classes. These are the most important areas in terms of degradation, as they have the lowest probability to be in a certain class, hence highest probability to be extended or narrowed down in next or previous class respectively. Eventually, these are the values which can be easily altered, under extrogenic influences, hence are identified as risk areas. The overall desertification risk is derived by incorporating the different risk severity of each parameter using fuzzy rule-based interference system in GIS environment. Multicriteria based geo-statistics are applied to locate the areas under different severity of desertification risk. The study revealed that in Kota, various anthropogenic pressures are accelerating land deterioration, coupled with natural erosive forces. Four major sources of desertification in Kota are, namely Gully and Ravine erosion, inappropriate mining practices, growing urbanization and random deforestation.

  7. Development of ultrasonic technique for measure of porosity of UO2 pellets

    International Nuclear Information System (INIS)

    Baroni, Douglas Brandao

    2008-01-01

    The characterization of nuclear fuel is of great importance to guarantee the efficiency and even the safety in the power stations. At present, the techniques used implicate elevated costs with equipment, materials and installations of radiological protection. Besides, because of being destructive techniques, they impose that the checking of the characteristics of this material is done by sampling. In this work a not destructive technique was developed for measures of porosity in ceramic materials with efficiency and precision. The objective of this work is to this technique will be able to be used in laboratory practice for measures in UO 2 pellets, so it would become viable the inspection of up to 100% of the nuclear fuel, guaranteeing bigger control of the characteristics of the used material, turning in increasing safety, efficiency and economy. The innovation of the technique is due to the fact of analysing the specter of frequency of the ultrasonic wrist, and not his time of course in the material, frequently used. In this work 40 ceramic pellets of alumina were used with values of porosity between 5,09% and 37,30%. A system of recognition of signs using artificial neural networks made possible to distinguish pellets with differences of porosity of 0,04%. It was observed that this technique can be used for several others aims, for example, in the determination of the void fraction in regimen of two-phase flow, what is very important to guarantee the efficiency and safety of nuclear reactors. (author)

  8. Nondestructive evaluation of reinforced plastics by a radiometric measurement technique

    International Nuclear Information System (INIS)

    Entine, Gerald; Afshari, Sia; Verlinden, Matt

    1990-01-01

    The demand for new high-performance plastics has greatly increased with advances in the performance characteristics of sophisticated reinforced engineering resins. However, conventional methods for the evaluation of the glass and filler contents of reinforced plastics are destructive, labor intensive, and time consuming. We have developed a new instrument, to address this problem, which provides for the rapid, accurate, and nondestructive measurement of glass or filler content in reinforced plastics. This instrument utilizes radiation transmission and scattering techniques for analytical measurement of glass, graphite and other fillers used in reinforced plastics. (author)

  9. An in vivo technique for the measurement of bone blood flow in animals

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; DeLuca, P.M. Jr.; Pearson, D.W.; Nickles, R.J.; Lehner, C.E.; Lanphier, E.H.

    1987-01-01

    A new technique to measure the in vivo clearance of 41 Ar from the bone mineral matrix is demonstrated following fast neutron production of 41 Ar in bone via the 44 Ca(n,α) reaction at 14.1 MeV. At the end of irradiation, the 41 Ar activity is assayed with a Ge(Li) detector where sequential gamma-ray spectra are taken. Following full-energy peak integration, background and dead time correction, the activity of 41 Ar as a function of time is determined. Results indicated that the Ar washout from bone in rats using this technique was approximately 16 ml (100 ml min) -1 and in agreement with other measurement techniques. For sheep the bone perfusion in the tibia was approximately 1.9+-0.2 ml (100 ml min) -1 . (author)

  10. A new technique to measure fission-product diffusion coefficients in UO2 fuel

    International Nuclear Information System (INIS)

    Hocking, W.H.; Verrall, R.A.; Bushby, S.J.

    1999-01-01

    This paper describes a new out-reactor technique for the measurement of fission-product diffusion rates in UO 2 . The technique accurately simulates in-reactor fission-fragment effects: a thermal diffusion that is due to localized mixing in the fission track, radiation-enhanced diffusion that is due to point-defect creation by fission fragments, and bubble resolution. The technique utilizes heavy-ion accelerators - low energy (40 keV to 1 MeV) for fission-product implantation, high energy (72 MeV) to create fission-fragment damage effects, and secondary ion mass spectrometry (SIMS) for measuring the depth profile of the implanted species. Preliminary results are presented from annealing tests (not in the 72 MeV ion flux) at 1465 deg. C and 1650 deg. C at low and high concentrations of fission products. (author)

  11. Automatic ultrasound technique to measure angle of progression during labor.

    Science.gov (United States)

    Conversano, F; Peccarisi, M; Pisani, P; Di Paola, M; De Marco, T; Franchini, R; Greco, A; D'Ambrogio, G; Casciaro, S

    2017-12-01

    To evaluate the accuracy and reliability of an automatic ultrasound technique for assessment of the angle of progression (AoP) during labor. Thirty-nine pregnant women in the second stage of labor, with fetus in cephalic presentation, underwent conventional labor management with additional translabial sonographic examination. AoP was measured in a total of 95 acquisition sessions, both automatically by an innovative algorithm and manually by an experienced sonographer, who was blinded to the algorithm outcome. The results obtained from the manual measurement were used as the reference against which the performance of the algorithm was assessed. In order to overcome the common difficulties encountered when visualizing by sonography the pubic symphysis, the AoP was measured by considering as the symphysis landmark its centroid rather than its distal point, thereby assuring high measurement reliability and reproducibility, while maintaining objectivity and accuracy in the evaluation of progression of labor. There was a strong and statistically significant correlation between AoP values measured by the algorithm and the reference values (r = 0.99, P < 0.001). The high accuracy provided by the automatic method was also highlighted by the corresponding high values of the coefficient of determination (r 2  = 0.98) and the low residual errors (root mean square error = 2°27' (2.1%)). The global agreement between the two methods, assessed through Bland-Altman analysis, resulted in a negligible mean difference of 1°1' (limits of agreement, 4°29'). The proposed automatic algorithm is a reliable technique for measurement of the AoP. Its (relative) operator-independence has the potential to reduce human errors and speed up ultrasound acquisition time, which should facilitate management of women during labor. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

  12. Techniques for intense-proton-beam profile measurements

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.

    1998-01-01

    In a collaborative effort with industry and several national laboratories, the Accelerator Production of Tritium (APT) facility and the Spallation Neutron Source (SNS) linac are presently being designed and developed at Los Alamos National Laboratory (LANL). The APT facility is planned to accelerate a 100-mA H + cw beam to 1.7 GeV and the SNS linac is planned to accelerate a 1- to 4-mA-average, H - , pulsed-beam to 1 GeV. With typical rms beam widths of 1- to 3-mm throughout much of these accelerators, the maximum average-power densities of these beams are expected to be approximately 30- and 1-MW-per-square millimeter, respectively. Such power densities are too large to use standard interceptive techniques typically used for acquisition of beam profile information. This paper summarizes the specific requirements for the beam profile measurements to be used in the APT, SNS, and the Low Energy Development Accelerator (LEDA)--a facility to verify the operation of the first 20-MeV section of APT. This paper also discusses the variety of profile measurement choices discussed at a recent high-average-current beam profile workshop held in Santa Fe, NM, and will present the present state of the design for the beam profile measurements planned for APT, SNS, and LEDA

  13. Microrheometric upconversion-based techniques for intracellular viscosity measurements

    Science.gov (United States)

    Rodríguez-Sevilla, Paloma; Zhang, Yuhai; de Sousa, Nuno; Marqués, Manuel I.; Sanz-Rodríguez, Francisco; Jaque, Daniel; Liu, Xiaogang; Haro-González, Patricia

    2017-08-01

    Rheological parameters (viscosity, creep compliance and elasticity) play an important role in cell function and viability. For this reason different strategies have been developed for their study. In this work, two new microrheometric techniques are presented. Both methods take advantage of the analysis of the polarized emission of an upconverting particle to determine its orientation inside the optical trap. Upconverting particles are optical materials that are able to convert infrared radiation into visible light. Their usefulness has been further boosted by the recent demonstration of their three-dimensional control and tracking by single beam infrared optical traps. In this work it is demonstrated that optical torques are responsible of the stable orientation of the upconverting particle inside the trap. Moreover, numerical calculations and experimental data allowed to use the rotation dynamics of the optically trapped upconverting particle for environmental sensing. In particular, the cytoplasm viscosity could be measured by using the rotation time and thermal fluctuations of an intracellular optically trapped upconverting particle, by means of the two previously mentioned microrheometric techniques.

  14. Software development with two port calibration techniques for RHIC impedance measurements

    International Nuclear Information System (INIS)

    Mane, V.; Shea, T.

    1993-01-01

    The coupling impedance of accelerator devices is measured by simulating the beam with a central wire and measuring the scattering parameters of the system. The wire pipe system forms a mismatch with the 50 ohm transmission line. An integrated software environment has been developed in LabVIEW, for the Macintosh. The program measures the scattering parameters of some known standards, determines the connect scattering parameters of a device using TRL calibration technique and gives the impedance of the device. Its performance has been tested for some known microwave devices

  15. Identifying and prioritizing the tools/techniques of knowledge management based on the Asian Productivity Organization Model (APO) to use in hospitals.

    Science.gov (United States)

    Khajouei, Hamid; Khajouei, Reza

    2017-12-01

    Appropriate knowledge, correct information, and relevant data are vital in medical diagnosis and treatment systems. Knowledge Management (KM) through its tools/techniques provides a pertinent framework for decision-making in healthcare systems. The objective of this study was to identify and prioritize the KM tools/techniques that apply to hospital setting. This is a descriptive-survey study. Data were collected using a -researcher-made questionnaire that was developed based on experts' opinions to select the appropriate tools/techniques from 26 tools/techniques of the Asian Productivity Organization (APO) model. Questions were categorized into five steps of KM (identifying, creating, storing, sharing, and applying the knowledge) according to this model. The study population consisted of middle and senior managers of hospitals and managing directors of Vice-Chancellor for Curative Affairs in Kerman University of Medical Sciences in Kerman, Iran. The data were analyzed in SPSS v.19 using one-sample t-test. Twelve out of 26 tools/techniques of the APO model were identified as the tools applicable in hospitals. "Knowledge café" and "APO knowledge management assessment tool" with respective means of 4.23 and 3.7 were the most and the least applicable tools in the knowledge identification step. "Mentor-mentee scheme", as well as "voice and Voice over Internet Protocol (VOIP)" with respective means of 4.20 and 3.52 were the most and the least applicable tools/techniques in the knowledge creation step. "Knowledge café" and "voice and VOIP" with respective means of 3.85 and 3.42 were the most and the least applicable tools/techniques in the knowledge storage step. "Peer assist and 'voice and VOIP' with respective means of 4.14 and 3.38 were the most and the least applicable tools/techniques in the knowledge sharing step. Finally, "knowledge worker competency plan" and "knowledge portal" with respective means of 4.38 and 3.85 were the most and the least applicable tools/techniques

  16. Flowing dusty plasma experiments: generation of flow and measurement techniques

    Science.gov (United States)

    Jaiswal, S.; Bandyopadhyay, P.; Sen, A.

    2016-12-01

    A variety of experimental techniques for the generation of subsonic/supersonic dust fluid flows and means of measuring such flow velocities are presented. The experiments have been carried out in a \\Pi -shaped dusty plasma experimental device with micron size kaolin/melamine formaldehyde particles embedded in a background of argon plasma created by a direct current glow discharge. A stationary dust cloud is formed over the cathode region by precisely balancing the pumping speed and gas flow rate. A flow of dust particles/fluid is generated by additional gas injection from a single or dual locations or by altering the dust confining potential. The flow velocity is then estimated by three different techniques, namely, by super particle identification code, particle image velocimetry analysis and the excitation of dust acoustic waves. The results obtained from these three different techniques along with their merits and demerits are discussed. An estimation of the neutral drag force responsible for the generation as well as the attenuation of the dust fluid flow is made. These techniques can be usefully employed in laboratory devices to investigate linear and non-linear collective excitations in a flowing dusty plasma.

  17. RF measurements I: signal receiving techniques

    CERN Document Server

    Caspers, F

    2011-01-01

    For the characterization of components, systems and signals in the RF and microwave range, several dedicated instruments are in use. In this paper the fundamentals of the RF-signal sampling technique, which has found widespread applications in 'digital' oscilloscopes and sampling scopes, are discussed. The key element in these front-ends is the Schottky diode which can be used either as an RF mixer or as a single sampler. The spectrum analyser has become an absolutely indispensable tool for RF signal analysis. Here the front-end is the RF mixer as the RF section of modern spectrum analysers has a rather complex architecture. The reasons for this complexity and certain working principles as well as limitations are discussed. In addition, an overview of the development of scalar and vector signal analysers is given. For the determination of the noise temperature of a one-port and the noise figure of a two-port, basic concepts and relations are shown. A brief discussion of commonly used noise measurement techniq...

  18. Certification of temperature measuring techniques at thermal and nuclear power plants

    International Nuclear Information System (INIS)

    Preobrazhenskij, V.P.; Strigina, L.A.

    1980-01-01

    Necessity for metrological certification of temperature measurement techniques (TMT) at thermal and nuclear energy plants is grounded. An order of TMT certification is stated and formulae for determining the accuracy of temperature measurements by the thermoelectric method are given. It is concluded that through there are also statistical characteristics of errors of a number of measurement properties, it is necessary to carry on statistical investigations into errors of thermoelectrode extending wires, planimeters, measurement conditions. Such kind investigation technigues have been developed. Besides, it is necessary to regulate a uniform approach to the usage of statistical characteristics of errors of means and conditions of measurements to minimize volume of work for the personnel of thermal and nuclear energy plants and provide reliable estimates of temperature measurement errors

  19. Adaptive digital fringe projection technique for high dynamic range three-dimensional shape measurement.

    Science.gov (United States)

    Lin, Hui; Gao, Jian; Mei, Qing; He, Yunbo; Liu, Junxiu; Wang, Xingjin

    2016-04-04

    It is a challenge for any optical method to measure objects with a large range of reflectivity variation across the surface. Image saturation results in incorrect intensities in captured fringe pattern images, leading to phase and measurement errors. This paper presents a new adaptive digital fringe projection technique which avoids image saturation and has a high signal to noise ratio (SNR) in the three-dimensional (3-D) shape measurement of objects that has a large range of reflectivity variation across the surface. Compared to previous high dynamic range 3-D scan methods using many exposures and fringe pattern projections, which consumes a lot of time, the proposed technique uses only two preliminary steps of fringe pattern projection and image capture to generate the adapted fringe patterns, by adaptively adjusting the pixel-wise intensity of the projected fringe patterns based on the saturated pixels in the captured images of the surface being measured. For the bright regions due to high surface reflectivity and high illumination by the ambient light and surfaces interreflections, the projected intensity is reduced just to be low enough to avoid image saturation. Simultaneously, the maximum intensity of 255 is used for those dark regions with low surface reflectivity to maintain high SNR. Our experiments demonstrate that the proposed technique can achieve higher 3-D measurement accuracy across a surface with a large range of reflectivity variation.

  20. Analytical methods to identify irradiated food

    International Nuclear Information System (INIS)

    Helle, N.; Schreiber, G.A.; Boegl, K.W.

    1992-01-01

    During the last years, three promising techniques for the identification of irradiated food were developed: - Studies of luminescence, mainly thermoluminescence measurements, of food containing mineral impurities like spices, dried vegetables: and fresh fuit and vegetables. This technique can probably be applied also to food with crystalline components like shells or bones. - Gaschromatographic/mass-spectrometric investigation of radiation-induced lipid changes. - Electron-spin-resonance measurements of dried products or of products containing dry components like bones, fish bones, shells or seeds. The thermoluminescence technique has been routinely applied for more than one year by several German Food Inspection Laboratories. The results suggest that there are scarcely any irradiated spices and dried vegetables in the German market. Gaschromatography/mass spectrometry of lipid components and electron-spin-resonance spectroscopy will be established in routine food inspections in Germany in the next two years. Further possibilities to identify irradiated food are the analysis of specific changes in amino acids, DNA and carbohydrates. Radiation-induced viscosity changes, and changes in electric properties (impedance) may be helpful in identifiying at least some irradiated products. Also microbiological and biological techniques as e.g. microbial flora shift or embryo development tests in citrus fruit have been considered. All activities concerning the development of identification techniques are now coordinated by the European Communities and by IAEA. (orig.) [de

  1. A reference data set for validating vapor pressure measurement techniques: homologous series of polyethylene glycols

    Science.gov (United States)

    Krieger, Ulrich K.; Siegrist, Franziska; Marcolli, Claudia; Emanuelsson, Eva U.; Gøbel, Freya M.; Bilde, Merete; Marsh, Aleksandra; Reid, Jonathan P.; Huisman, Andrew J.; Riipinen, Ilona; Hyttinen, Noora; Myllys, Nanna; Kurtén, Theo; Bannan, Thomas; Percival, Carl J.; Topping, David

    2018-01-01

    To predict atmospheric partitioning of organic compounds between gas and aerosol particle phase based on explicit models for gas phase chemistry, saturation vapor pressures of the compounds need to be estimated. Estimation methods based on functional group contributions require training sets of compounds with well-established saturation vapor pressures. However, vapor pressures of semivolatile and low-volatility organic molecules at atmospheric temperatures reported in the literature often differ by several orders of magnitude between measurement techniques. These discrepancies exceed the stated uncertainty of each technique which is generally reported to be smaller than a factor of 2. At present, there is no general reference technique for measuring saturation vapor pressures of atmospherically relevant compounds with low vapor pressures at atmospheric temperatures. To address this problem, we measured vapor pressures with different techniques over a wide temperature range for intercomparison and to establish a reliable training set. We determined saturation vapor pressures for the homologous series of polyethylene glycols (H - (O - CH2 - CH2)n - OH) for n = 3 to n = 8 ranging in vapor pressure at 298 K from 10-7 to 5×10-2 Pa and compare them with quantum chemistry calculations. Such a homologous series provides a reference set that covers several orders of magnitude in saturation vapor pressure, allowing a critical assessment of the lower limits of detection of vapor pressures for the different techniques as well as permitting the identification of potential sources of systematic error. Also, internal consistency within the series allows outlying data to be rejected more easily. Most of the measured vapor pressures agreed within the stated uncertainty range. Deviations mostly occurred for vapor pressure values approaching the lower detection limit of a technique. The good agreement between the measurement techniques (some of which are sensitive to the mass

  2. Outside-out "sniffer-patch" clamp technique for in situ measures of neurotransmitter release.

    Science.gov (United States)

    Muller-Chrétien, Emilie

    2014-01-01

    The mechanism underlying neurotransmitter release is a critical research domain for the understanding of neuronal network function; however, few techniques are available for the direct detection and measurement of neurotransmitter release. To date, the sniffer-patch clamp technique is mainly used to investigate these mechanisms from individual cultured cells. In this study, we propose to adapt the sniffer-patch clamp technique to in situ detection of neurosecretion. Using outside-out patches from donor cells as specific biosensors plunged in acute cerebral slices, this technique allows for proper detection and quantification of neurotransmitter release at the level of the neuronal network.

  3. The immediate effect of individual manipulation techniques on pulmonary function measures in persons with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Noll, Donald R; Johnson, Jane C; Baer, Robert W; Snider, Eric J

    2009-10-08

    The use of manipulation has long been advocated in the treatment of chronic obstructive pulmonary disease (COPD), but few randomized controlled clinical trials have measured the effect of manipulation on pulmonary function. In addition, the effects of individual manipulative techniques on the pulmonary system are poorly understood. Therefore, the purpose of this study was to determine the immediate effects of four osteopathic techniques on pulmonary function measures in persons with COPD relative to a minimal-touch control protocol. Persons with COPD aged 50 and over were recruited for the study. Subjects received five, single-technique treatment sessions: minimal-touch control, thoracic lymphatic pump (TLP) with activation, TLP without activation, rib raising, and myofascial release. There was a 4-week washout period between sessions. Protocols were given in random order until all five techniques had been administered. Pulmonary function measures were obtained at baseline and 30-minutes posttreatment. For the actual pulmonary function measures and percent predicted values, Wilcoxon signed rank tests were used to test within-technique changes from baseline. For the percent change from baseline, Friedman tests were used to test for between-technique differences. Twenty-five subjects were enrolled in the study. All four tested osteopathic techniques were associated with adverse posttreatment changes in pulmonary function measures; however, different techniques changed different measures. TLP with activation increased posttreatment residual volume compared to baseline, while TLP without activation did not. Side effects were mild, mostly posttreatment chest wall soreness. Surprisingly, the majority of subjects believed they could breathe better after receiving osteopathic manipulation. In persons with COPD, TLP with activation, TLP without activation, rib raising, and myofascial release mildly worsened pulmonary function measures immediately posttreatment relative to

  4. Mechanical seal monitoring technique by acoustic emission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Tadashi; Fujita, Yoshihiro; Kawaguchi, Kazunori; Saito, Kazuhiro; Yokota, Setsuo; Hisada, Yasuhide; Masahiro, Komatsu

    1987-09-20

    This report describes a technique for mechanical seal monitoring through acoustic emission (AE) measurement. The equipment consists of an AE sensor, preamplifier, multiplexer, main amplifier, effective value transducer and computer system. When the sealed liquid pressure undergoes a large change, the seal surface configuration is monitored and evaluated accurately through AE measurement. If the mechanical seal surface id damaged or worn, the AE level is kept high or continues to fluctuate largely for a rather long period. When leak occurs, the AE value shows great fluctuations either at extremely low levels or at high levels. The former trend is considered to result from a decrease in solid contact due to an excessive amount of liquid film being formed at the seal surface during leak. In the latter case, the leak is attributed to severe damage to the seal surface. (18 figs, 1 tab, 5 photos, 3 refs)

  5. Thermal effusivity measurement of conventional and organic coffee oils via photopyroelectric technique.

    Science.gov (United States)

    Bedoya, A; Gordillo-Delgado, F; Cruz-Santillana, Y E; Plazas, J; Marin, E

    2017-12-01

    In this work, oil samples extracted from organic and conventional coffee beans were studied. A fatty acids profile analysis was done using gas chromatography and physicochemical analysis of density and acidity index to verify the oil purity. Additionally, Mid-Infrared Fourier Transform Photoacoustic Spectroscopy (FTIR-PAS) aided by Principal Component Analysis (PCA) was used to identify differences between the intensities of the absorption bands related to functional groups. Thermal effusivity values between 592±3 and 610±4Ws 1/2 m -2 K -1 were measured using the photopyroelectric technique in a front detection configuration. The acidity index was between 1.11 and 1.27% and the density changed between 0.921 and 0.94g/mL. These variables, as well as the extraction yield between 12,6 and 14,4%, showed a similar behavior than that observed for the thermal effusivity, demonstrating that this parameter can be used as a criterion for discrimination between oil samples extracted from organic and conventional coffee beans. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A technique system for the measurement, reconstruction and character extraction of rice plant architecture.

    Directory of Open Access Journals (Sweden)

    Xumeng Li

    Full Text Available This study developed a technique system for the measurement, reconstruction, and trait extraction of rice canopy architectures, which have challenged functional-structural plant modeling for decades and have become the foundation of the design of ideo-plant architectures. The system uses the location-separation-measurement method (LSMM for the collection of data on the canopy architecture and the analytic geometry method for the reconstruction and visualization of the three-dimensional (3D digital architecture of the rice plant. It also uses the virtual clipping method for extracting the key traits of the canopy architecture such as the leaf area, inclination, and azimuth distribution in spatial coordinates. To establish the technique system, we developed (i simple tools to measure the spatial position of the stem axis and azimuth of the leaf midrib and to capture images of tillers and leaves; (ii computer software programs for extracting data on stem diameter, leaf nodes, and leaf midrib curves from the tiller images and data on leaf length, width, and shape from the leaf images; (iii a database of digital architectures that stores the measured data and facilitates the reconstruction of the 3D visual architecture and the extraction of architectural traits; and (iv computation algorithms for virtual clipping to stratify the rice canopy, to extend the stratified surface from the horizontal plane to a general curved surface (including a cylindrical surface, and to implement in silico. Each component of the technique system was quantitatively validated and visually compared to images, and the sensitivity of the virtual clipping algorithms was analyzed. This technique is inexpensive and accurate and provides high throughput for the measurement, reconstruction, and trait extraction of rice canopy architectures. The technique provides a more practical method of data collection to serve functional-structural plant models of rice and for the

  7. Measurement techniques for in situ stresses around underground constructions in a deep clay formation

    Directory of Open Access Journals (Sweden)

    Li X.L.

    2010-06-01

    Full Text Available Disposal in deep underground geological formations is internationally recognized as the most viable option for the long-term management of high-level radioactive waste. In Belgium, the Boom clay formation is extensively studied in this context, in particular at the 225 m deep HADES Underground Research Facility in Mol. A cost-effective design of deep underground structures requires an accurate assessment of the in situ stresses; a good estimation of these stresses is also essential when interpreting in situ experiments regarding the hydro-mechanical behaviour of the host formation. Different measurement techniques are available to provide data on the stress evolution and other mechanical properties of the geological formation. The measurement can be direct (measurement of total pressure, or it can be an indirect technique, deriving the stress from related quantities such as strain (changes in structural members. Most total stress measurements are performed through permanently installed sensors; also once-only measurements are performed through specific methods (e.g. pressuremeter. Direct measurement of the stress state is challenging due to the complex mechanical behaviour of the clay, and the fact that the sensor installation inevitably disturbs the original stress field. This paper describes ways to deal with these problems and presents the results obtained using different techniques at HADES.

  8. Perspectives on Measurement Instruction.

    Science.gov (United States)

    Airasian, Peter W.

    1991-01-01

    This paper seeks to identify ways of making measurement more relevant to classroom teachers, and making classroom realities more apparent to measurement specialists. Measurement elements of teacher education textbooks and courses, nontraditional assessment topics, informal classroom measurement techniques, terminological issues, and three types of…

  9. Measuring techniques for the characterisation of 137Cs contaminated river banks, Slovakia

    International Nuclear Information System (INIS)

    Slavik, O.; Moravek, J.

    2000-01-01

    In 1990, 137 Cs contaminated areas were discovered along 19 km of the banks of the rivers receiving discharged waste waters from the Bohunice NPP. The contamination was the result of uncontrolled releases of drainage water from the radioactive waste treatment unit and two accidents on the CO 2 cooled and heavy water moderated NPP-A1 unit in 1976 and 1977. In total, more than 67.000 m 2 of bank surfaces (the lower and middle parts of their slopes) have been found to be contaminated with 137 Cs at levels exceeding 1 kBq/kg of soil. This paper describes the planning for restoration of these river banks with emphasis on site characterization techniques used for these purposes. The general strategy and application of monitoring techniques for the purposes of characterisation of contaminated river banks is the main topic of the work performed in the context of the IAEA CRP on 'Site Characterisation Techniques for Environmental Restoration'. First results in developing new and more sophisticated measuring techniques, needed for the characterization of discontinuous and spot-contamination found on parts of the banks are given. The technique described is based on a dose rate measurement approach, using ratio of two detector readings at two different distances above ground and Monte-Carlo simulations of the plastic scintillation detector responses. The method will also be useful, for the final, post-remediation survey of residual spots of 137 Cs contamination. (author)

  10. A safeguards verification technique for solution homogeneity and volume measurements in process tanks

    International Nuclear Information System (INIS)

    Suda, S.; Franssen, F.

    1987-01-01

    A safeguards verification technique is being developed for determining whether process-liquid homogeneity has been achieved in process tanks and for authenticating volume-measurement algorithms involving temperature corrections. It is proposed that, in new designs for bulk-handling plants employing automated process lines, bubbler probes and thermocouples be installed at several heights in key accountability tanks. High-accuracy measurements of density using an electromanometer can now be made which match or even exceed analytical-laboratory accuracies. Together with regional determination of tank temperatures, these measurements provide density, liquid-column weight and temperature gradients over the fill range of the tank that can be used to ascertain when the tank solution has reached equilibrium. Temperature-correction algorithms can be authenticated by comparing the volumes obtained from the several bubbler-probe liquid-height measurements, each based on different amounts of liquid above and below the probe. The verification technique is based on the automated electromanometer system developed by Brookhaven National Laboratory (BNL). The IAEA has recently approved the purchase of a stainless-steel tank equipped with multiple bubbler and thermocouple probes for installation in its Bulk Calibration Laboratory at IAEA Headquarters, Vienna. The verification technique is scheduled for preliminary trials in late 1987

  11. Towards convective heat transfer enhancement: surface modification, characterization and measurement techniques

    NARCIS (Netherlands)

    Taha, T.J.; Thakur, D.B.; van der Meer, Theodorus H.

    2012-01-01

    In this work, heat transfer surface modification and heat transfer measurement technique is developed. Heat transfer investigation was aimed to study the effect of carbon nano fibers (extremely high thermal conductive material) on the enhancement level in heat transfer. Synthesis of these carbon

  12. Adjustments of microwave-based measurements on coal moisture using natural radioactivity techniques

    Energy Technology Data Exchange (ETDEWEB)

    Prieto-Fernandez, I.; Luengo-Garcia, J.C.; Alonso-Hidalgo, M.; Folgueras-Diaz, B. [University of Oviedo, Gijon (Spain)

    2006-01-07

    The use of nonconventional on-line measurements of moisture and ash content in coal is presented. The background research is briefly reviewed. The possibilities of adjusting microwave-based moisture measurements using natural radioactive techniques, and vice versa, are proposed. The results obtained from the simultaneous analysis of moisture and ash content as well as the correlation improvements are shown.

  13. Gamma-rays attenuation of zircons from Cambodia and South Africa at different energies: A new technique for identifying the origin of gemstone

    International Nuclear Information System (INIS)

    Limkitjaroenporn, P.; Kaewkhao, J.

    2014-01-01

    In this work, the gamma-rays interaction properties of zircons from Cambodia and South Africa have been studied. The densities of Cambodian and South African’s zircons are 4.6716±0.0040 g/cm 3 and 4.5505±0.0018 g/cm 3 , respectively. The mass attenuation coefficient and the effective atomic number of gemstones were measured with the gamma-ray in energies range 223–662 keV using the Compton scattering technique. The mass attenuation coefficients of both zircons decreased with the increasing of gamma-rays energies. The different mass attenuation coefficients between the two zircons observed at gamma-ray energies below 400 keV are attributed to the differences in the photoelectric interaction. The effective atomic number of zircons was decreased with the increasing of gamma-ray energies and showed totally different values between the Cambodia and South Africa sources. The origins of the two zircons could be successfully identified by the method based on gamma-rays interaction with matter with advantage of being a non-destructive testing. - Highlights: • Gamma-rays interaction of zircons from Cambodia and South Africa studied. • Measured energy is during 223–662 keV. • Different μ m between the two zircons observed at gamma-ray energies below 400 keV. • The origins the two zircons could be successfully identified

  14. INSTRUMENTS MEASURING PERCEIVED RACISM/RACIAL DISCRIMINATION: REVIEW AND CRITIQUE OF FACTOR ANALYTIC TECHNIQUES

    Science.gov (United States)

    Atkins, Rahshida

    2015-01-01

    Several compendiums of instruments that measure perceived racism and/or discrimination are present in the literature. Other works have reviewed the psychometric properties of these instruments in terms of validity and reliability and have indicated if the instrument was factor analyzed. However, little attention has been given to the quality of the factor analysis performed. The aim of this study was to evaluate the exploratory factor analyses done on instruments measuring perceived racism/racial discrimination using guidelines from experts in psychometric theory. The techniques used for factor analysis were reviewed and critiqued and the adequacy of reporting was evaluated. Internet search engines and four electronic abstract databases were used to identify 16 relevant instruments that met the inclusion/exclusion criteria. Principal component analysis was the most frequent method of extraction (81%). Sample sizes were adequate for factor analysis in 81 percent of studies. The majority of studies reported appropriate criteria for the acceptance of un-rotated factors (81%) and justified the rotation method (75%). Exactly 94 percent of studies reported partially acceptable criteria for the acceptance of rotated factors. The majority of articles (69%) reported adequate coefficient alphas for the resultant subscales. In 81 percent of the studies, the conceptualized dimensions were supported by factor analysis. PMID:25626225

  15. Objective Assessment of Sunburn and Minimal Erythema Doses: Comparison of Noninvasive In Vivo Measuring Techniques after UVB Irradiation

    Directory of Open Access Journals (Sweden)

    Lo Pei-Yu

    2010-01-01

    Full Text Available Military personnel movement is exposed to solar radiation and sunburn is a major problem which can cause lost workdays and lead to disciplinary action. This study was designed to identify correlation parameters in evaluating in vivo doses and epidermis changes following sunburn inflammation. Several noninvasive bioengineering techniques have made objective evaluations possible. The volar forearms of healthy volunteers ( , 2 areas, 20 mm in diameter, were irradiated with UVB 100 mj/ and 200 mj/ , respectively. The skin changes were recorded by several monitored techniques before and 24 hours after UV exposures. Our results showed that chromameter value provides more reliable information and can be adopted with mathematical model in predicting the minimal erythema dose (MED which showed lower than visual assessment by 10 mj/ (Pearson correlation coefficient . A more objective measure for evaluation of MED was established for photosensitive subjects' prediction and sunburn risks prevention.

  16. Decoupling pipeline influences in soil resistivity measurements with finite element techniques

    Science.gov (United States)

    Deo, R. N.; Azoor, R. M.; Zhang, C.; Kodikara, J. K.

    2018-03-01

    Periodic inspection of pipeline conditions is an important asset management strategy conducted by water and sewer utilities for efficient and economical operations of their assets in field. The Level 1 pipeline condition assessment involving resistivity profiling along the pipeline right-of-way is a common technique for delineating pipe sections that might be installed in highly corrosive soil environment. However, the technique can suffer from significant perturbations arising from the buried pipe itself, resulting in errors in native soil characterisation. To address this problem, a finite element model was developed to investigate the degree to which pipes of different a) diameters, b) burial depths, and c) surface conditions (bare or coated) can influence in-situ soil resistivity measurements using Wenner methods. It was found that the greatest errors can arise when conducting measurements over a bare pipe with the array aligned parallel to the pipe. Depending upon the pipe surface conditions, in-situ resistivity measurements can either be underestimated or overestimated from true soil resistivities. Following results based on simulations and decoupling equations, a guiding framework for removing pipe influences in soil resistivity measurements were developed that can be easily used to perform corrections on measurements. The equations require simple a-prior information on the pipe diameter, burial depth, surface condition, and the array length and orientation used. Findings from this study have immediate application and is envisaged to be useful for critical civil infrastructure monitoring and assessment.

  17. Comparison of safety measures with a multicriteria decision aiding technique

    International Nuclear Information System (INIS)

    Lombard, J.

    1985-01-01

    Attributes such as political, social and psychological factors have to be taken into account for the decision-making process. Multiattribute decision-aiding techniques are used to cope with this multidimensionality of the risk management process. A simple example will be given to illustrate how such method can be helpful for the selection of proper safety measures in a rational way. (orig./HP) [de

  18. Accuracy of MRI technique in measuring tendon cross-sectional area

    DEFF Research Database (Denmark)

    Couppé, Christian; Svensson, R. B.; Elbrønd (Bibs), Vibeke Sødring

    2014-01-01

    , but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the patellar...... tendon CSA. Thereafter, the patellar tendon of the horse was completely dissected and embedded in an alginate cast. The CSA of the embedded tendon was measured directly by optical imaging of the cast impression. 1.5 tesla grey tendon CSA and 3 tesla grey tendon CSA were 16.5% and 13.2% lower than...... the mould tendon CSA, respectively. Also, 3 tesla tendon CSA, based on the red-green border on the National Institute of Health (NIH) colour scale, was lower than the mould tendon CSA by 2.8%. The typical error between examiners was below 2% for all the measured CSA. The typical error between examiners...

  19. Intelligent Technique for Signal Processing to Identify the Brain Disorder for Epilepsy Captures Using Fuzzy Systems

    Directory of Open Access Journals (Sweden)

    Gurumurthy Sasikumar

    2016-01-01

    Full Text Available The new direction of understand the signal that is created from the brain organization is one of the main chores in the brain signal processing. Amid all the neurological disorders the human brain epilepsy is measured as one of the extreme prevalent and then programmed artificial intelligence detection technique is an essential due to the crooked and unpredictable nature of happening of epileptic seizures. We proposed an Improved Fuzzy firefly algorithm, which would enhance the classification of the brain signal efficiently with minimum iteration. An important bunching technique created on fuzzy logic is the Fuzzy C means. Together in the feature domain with the spatial domain the features gained after multichannel EEG signals remained combined by means of fuzzy algorithms. And for better precision segmentation process the firefly algorithm is applied to optimize the Fuzzy C-means membership function. Simultaneously for the efficient clustering method the convergence criteria are set. On the whole the proposed technique yields more accurate results and that gives an edge over other techniques. This proposed algorithm result compared with other algorithms like fuzzy c means algorithm and PSO algorithm.

  20. An improved approach to identify irradiated dog feed by electron paramagnetic resonance study and thermoluminescence measurements

    International Nuclear Information System (INIS)

    Sanyal, Bhaskar; Chawla, S.P.; Sharma, Arun

    2011-01-01

    In the present study, probably for the first time, a detailed analysis of the radiation induced radical species and thermoluminescence measurements of irradiated dog feed are reported. The EPR spectrum of non-irradiated ready-to-eat dog feed was characterized by singlet g=2.0047±0.0003. Irradiated samples exhibited a complex EPR spectrum. During high power (50.0 mW) EPR spectroscopy, a visible change in the shape of the EPR spectrum was observed and characterized by EPR spectrum simulation technique. An axially symmetric anisotropic signal with g || =2.0028 and g perpendicular =1.9976 was identified. However, a negligible change in the matrix of irradiated edible dog chew was observed using EPR spectroscopy. Therefore, thermoluminescence study of the isolated minerals from dog chew was carried out. The composition of the poly-minerals was studied using SEM and EDX analysis and a complete verdict on identification of irradiation is proposed.

  1. An improved approach to identify irradiated dog feed by electron paramagnetic resonance study and thermoluminescence measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sanyal, Bhaskar, E-mail: bhaskar_sanyal@rediffmail.co [Food Technology Division, Bhabha Atomic Research Centre, Mumbai-400 085 (India); Chawla, S.P.; Sharma, Arun [Food Technology Division, Bhabha Atomic Research Centre, Mumbai-400 085 (India)

    2011-05-15

    In the present study, probably for the first time, a detailed analysis of the radiation induced radical species and thermoluminescence measurements of irradiated dog feed are reported. The EPR spectrum of non-irradiated ready-to-eat dog feed was characterized by singlet g=2.0047{+-}0.0003. Irradiated samples exhibited a complex EPR spectrum. During high power (50.0 mW) EPR spectroscopy, a visible change in the shape of the EPR spectrum was observed and characterized by EPR spectrum simulation technique. An axially symmetric anisotropic signal with g{sub ||}=2.0028 and g{sub perpendicular}=1.9976 was identified. However, a negligible change in the matrix of irradiated edible dog chew was observed using EPR spectroscopy. Therefore, thermoluminescence study of the isolated minerals from dog chew was carried out. The composition of the poly-minerals was studied using SEM and EDX analysis and a complete verdict on identification of irradiation is proposed.

  2. Hyperfine interactions measured by nuclear orientation technique

    International Nuclear Information System (INIS)

    Brenier, R.

    1982-01-01

    This report concerns the use of hyperfine interaction to magnetism measurements and to the determination of the nuclear structure of Terbium isotopes by the low temperature nuclear orientation technique. In the first part we show that the rhodium atom does not support any localized moment in the chromium matrix. The hyperfine magnetic field at the rhodium nuclear site follows the Overhauser distribution, and the external applied magnetic field supports a negative Knight shift of 16%. In the second part we consider the structure of neutron deficient Terbium isotopes. We introduce a coherent way of evaluation and elaborate a new nuclear thermometer. The magnetic moments allows to strike on the studied states configuration. The analysis of our results shows a decrease of the nuclear deformation for the lighter isotopes [fr

  3. Measurement of morphing wing deflection by a cross-coherence fiber optic interferometric technique

    Science.gov (United States)

    Tomić, Miloš C.; Djinović, Zoran V.; Scheerer, Michael; Petricevic, Slobodan J.

    2018-01-01

    A fiber-optic interferometric technique aimed at measuring the deflection of aircrafts’ morphing wings is presented. The wing deflection induces a strain in the sensing fiber optic coils that are firmly fixed onto the wing. A change of the phase angle of the light propagating through the fiber is measured by an ‘all-in-fiber’ Michelson interferometer based on a 3 × 3 fiber-optic coupler. Two light sources of different coherence lengths and wavelengths are simultaneously used to ensure a wide measurement range and high accuracy. A new technique for determination of the zero deflection point using the cross-correlation of the two interferograms is proposed. The experiments performed on a specimen made of a carbon-fiber-reinforced plastic honeycomb structure demonstrated a relative uncertainty morphing wing deflection.

  4. Techniques for measuring customers’ satisfaction in Banks

    Directory of Open Access Journals (Sweden)

    Elena Lidia MELNIC

    2016-07-01

    Full Text Available The major concern of banks today is to recover and maintain customer trust. Customers need to feel that banks are considering their best interests. Customers are seeking for easy and personalized information. They want to better understand their financial situation and to control it. They want to know both the benefits, as well as the risks. Clients want to work with banks that are concerned about them and about their personal goals. However, only an attractive offer of banks is not the key to success today if is not supported by a superior service culture, that can make notable differentiation in the market. Many banks all over the world are systematically measuring how well they treat customers, identifying the factors shaping satisfaction, and changing operations and marketing as a result. Wise banks measure customer satisfaction regularly because it is one key to customer retention.

  5. Comparison of 210Pb level in Kuala Muda tsunami affected marine sediment core measured using two different techniques

    International Nuclear Information System (INIS)

    Yii Mei Wo; Zal Uyun Wan Mahmood; Jalal Sharib; Zaharudin Ahmad

    2010-01-01

    The most commonly used techniques of alpha and gamma spectrometry were compared to measure 210 Pb activity in marine sediment core. Alpha analytical technique measured the activity of 210 Pb from its in-grow grand-daughter 210 Po after a chemical separation by assuming that there is radioactive equilibrium between the two radionuclides. Meanwhile, gamma analysis technique allows direct measurement, non-destructive and no preliminary chemical separation. Through the comparison, it was found that both alpha and gamma analysis techniques were slightly different. Overall, the results from gamma analytical technique were higher than those from the alpha analytical techniques. Some logical argument had been discussed to explain this situation. In routine analysis, the analytical technique used should be chosen carefully based on advantages and disadvantages of the each technique and analysis requirements. Therefore, it is recommended to determine the exact needs and purpose of analysis and to know the sample history before deciding the appropriate analytical technique. (author)

  6. Inverse kinetics technique for reactor shutdown measurement: an experimental assessment. [AGR

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, T. A.; McDonald, D.

    1975-09-15

    It is proposed to use the Inverse Kinetics Technique to measure the subcritical reactivity as a function of time during the testing of the nitrogen injection systems on AGRs. A description is given of an experimental assessment of the technique by investigating known transients created by control rod movements on a small experimental reactor, (2m high, 1m radius). Spatial effects were observed close to the moving rods but otherwise derived reactivities were independent of detector position and agreed well with the existing calibrations. This prompted the suggestion that data from installed reactor instrumentation could be used to calibrate CAGR control rods.

  7. Assessing energy techniques and measures in residential buildings: a multidisciplinary perspective

    NARCIS (Netherlands)

    Entrop, Alexis Gerardus

    2013-01-01

    Many Energy Techniques and Measures (ETMs) are available to reduce the fossil energy use of residential buildings. However, the rate at which these ETMs are implemented is relatively low. Bram Entrop (1980) addresses, in this design-oriented research, the influence that ETMs have on the energy

  8. Minimal interference beam size/profile measurement techniques applicable to the Collider

    International Nuclear Information System (INIS)

    Nexsen, W.; Dutt, S.; Kauffmann, S.; Lebedev, V.; Maschke, A.; Mokhov, N.; Richardson, R.; Tsyganov, E.; Zinchenko, A.

    1993-05-01

    The imaging of synchrotron radiation (SR) has been suggested as a technique for providing a continuous, non-interfering monitor of the beam profile in the Collider rings at the Superconducting Super Collider. A closer examination has raised questions concerning the applicability of SR imaging in this case because of the diffraction broadening of the image, the requirements for axial space and location in the lattice, and the complexity of the system. We have surveyed the known, alternative, minimal interference techniques for measuring beam size and have evaluated them for possible Collider usage. We conclude that of the approaches that appear feasible, all require at least some development for our usage and that the development of an electron beam probe offers the best promise. We recommend that flying wires be used for cross-checking and calibrating the electron beam probe diagnostic and for luminosity measurements when the highest accuracy is required, but flying wires should not be used as the primary diagnostic because of their limited lifetime

  9. Continuous Measurements and Quantitative Constraints: Challenge Problems for Discrete Modeling Techniques

    Science.gov (United States)

    Goodrich, Charles H.; Kurien, James; Clancy, Daniel (Technical Monitor)

    2001-01-01

    We present some diagnosis and control problems that are difficult to solve with discrete or purely qualitative techniques. We analyze the nature of the problems, classify them and explain why they are frequently encountered in systems with closed loop control. This paper illustrates the problem with several examples drawn from industrial and aerospace applications and presents detailed information on one important application: In-Situ Resource Utilization (ISRU) on Mars. The model for an ISRU plant is analyzed showing where qualitative techniques are inadequate to identify certain failure modes and to maintain control of the system in degraded environments. We show why the solution to the problem will result in significantly more robust and reliable control systems. Finally, we illustrate requirements for a solution to the problem by means of examples.

  10. Correlation techniques for the improvement of signal-to-noise ratio in measurements with stochastic processes

    CERN Document Server

    Reddy, V R; Reddy, T G; Reddy, P Y; Reddy, K R

    2003-01-01

    An AC modulation technique is described to convert stochastic signal variations into an amplitude variation and its retrieval through Fourier analysis. It is shown that this AC detection of signals of stochastic processes when processed through auto- and cross-correlation techniques improve the signal-to-noise ratio; the correlation techniques serve a similar purpose of frequency and phase filtering as that of phase-sensitive detection. A few model calculations applied to nuclear spectroscopy measurements such as Angular Correlations, Mossbauer spectroscopy and Pulse Height Analysis reveal considerable improvement in the sensitivity of signal detection. Experimental implementation of the technique is presented in terms of amplitude variations of harmonics representing the derivatives of normal spectra. Improved detection sensitivity to spectral variations is shown to be significant. These correlation techniques are general and can be made applicable to all the fields of particle counting where measurements ar...

  11. A New Technique for SET Pulse Width Measurement in Chains of Inverters Using Pulsed Laser Irradiation

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Fel, N.; Gaillardin, M.; Baggio, J.; Girard, S.; Flament, O.; Paillet, P.; McMorrow, D.; Melinger, J. S.; Kobayashi, D.; Hirose, K.; Saito, H.; Pouget, V.; Essely, F.; Schwank, J. R.; Flores, R. S.; Dodd, P. E.; Shaneyfelt, M. R.

    2009-01-01

    A new technique is developed to measure precisely and accurately the width of propagating voltage transients induced by irradiation of inverter chains. The technique is based on measurement of the supply current in a detection inverter, and permits a direct determination of the transient width with a 50 GHz bandwidth. (authors)

  12. A technique for measuring oxygen saturation in biological tissues based on diffuse optical spectroscopy

    Science.gov (United States)

    Kleshnin, Mikhail; Orlova, Anna; Kirillin, Mikhail; Golubiatnikov, German; Turchin, Ilya

    2017-07-01

    A new approach to optical measuring blood oxygen saturation was developed and implemented. This technique is based on an original three-stage algorithm for reconstructing the relative concentration of biological chromophores (hemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the probing radiation source. The numerical experiments and approbation of the proposed technique on a biological phantom have shown the high reconstruction accuracy and the possibility of correct calculation of hemoglobin oxygenation in the presence of additive noise and calibration errors. The obtained results of animal studies have agreed with the previously published results of other research groups and demonstrated the possibility to apply the developed technique to monitor oxygen saturation in tumor tissue.

  13. Airflow measurement techniques applied to radon mitigation problems

    International Nuclear Information System (INIS)

    Harrje, D.T.; Gadsby, K.J.

    1989-01-01

    During the past decade a multitude of diagnostic procedures associated with the evaluation of air infiltration and air leakage sites have been developed. The spirit of international cooperation and exchange of ideas within the AIC-AIVC conferences has greatly facilitated the adoption and use of these measurement techniques in the countries participating in Annex V. But wide application of such diagnostic methods are not limited to air infiltration alone. The subject of this paper concerns the ways to evaluate and improve radon reduction in buildings using diagnostic methods directly related to developments familiar to the AIVC. Radon problems are certainly not unique to the United States, and the methods described here have to a degree been applied by researchers of other countries faced with similar problems. The radon problem involves more than a harmful pollutant of the living spaces of our buildings -- it also involves energy to operate radon removal equipment and the loss of interior conditioned air as a direct result. The techniques used for air infiltration evaluation will be shown to be very useful in dealing with the radon mitigation challenge. 10 refs., 7 figs., 1 tab

  14. Three-dimensional trace measurements for fast-moving objects using binary-encoded fringe projection techniques.

    Science.gov (United States)

    Su, Wei-Hung; Kuo, Cho-Yo; Kao, Fu-Jen

    2014-08-20

    A fringe projection technique to trace the shape of a fast-moving object is proposed. A binary-encoded fringe pattern is illuminated by a strobe lamp and then projected onto the moving object at a sequence of time. Phases of the projected fringes obtained from the sequent measurements are extracted by the Fourier transform method. Unwrapping is then performed with reference to the binary-encoded fringe pattern. Even though the inspected object is colorful, fringe orders can be identified. A stream of profiles is therefore retrieved from the sequent unwrapped phases. This makes it possible to analyze physical properties of the dynamic objects. Advantages of the binary-encoded fringe pattern for phase unwrapping also include (1) reliable performance for colorful objects, spatially isolated objects, and surfaces with large depth discontinuities; (2) unwrapped errors only confined in a local area; and (3) low computation cost.

  15. New test structures and techniques for measurement of mechanical properties of MEMS materials

    Science.gov (United States)

    Sharpe, William N., Jr.; Yuan, Bin; Vaidyanathan, Ranji; Edwards, Richard L.

    1996-09-01

    This paper presents techniques and procedures for addressing the three major problems of mechanical testing of the thin films used in surface micromachined microelectromechanical systems--specimen handling, friction, and strain measurement. The polysilicon tensile specimens are fabricated with two supporting side strips on silicon wafers at the Microelectronic Center of North Carolina. The tensile specimen is released by etching away the wafer, and the two support strips are cut after the specimen is glued in the test machine. Friction is reduced by a linear air bearing in the load train, and strain is measured with a noncontacting technique based on laser interferometry between two gold lines on the tensile specimen. The Young's modulus of polysilicon is 170 +/- 7 GPa and the strength is 1.21 +/- 0.16 GPa from a series of 29 tests. preliminary measurements have been made of Poisson's ratio and the fatigue behavior, and an attempt is underway to measure the fracture toughness.

  16. Reliable cost effective technique for in situ ground stress measurements in deep gold mines.

    CSIR Research Space (South Africa)

    Stacey, TR

    1995-07-01

    Full Text Available on these requirements, an in situ stress measurement technique which will be practically applicable in the deep gold mines, has been developed conceptually. Referring to the figure on the following page, this method involves: • a borehole-based system, using... level mines have not been developed. 2 This is some of the background to the present SIMRAC research project, the title ofwhich is “Reliable cost effective technique for in-situ ground stress measurements in deep gold mines”. A copy of the research...

  17. Experimental technique to measure thoron generation rate of building material samples using RAD7 detector

    International Nuclear Information System (INIS)

    Csige, I.; Szabó, Zs.; Szabó, Cs.

    2013-01-01

    Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in building material samples using RAD7 radon-thoron detector. The mathematical model of the measurement technique provides the thoron concentration response of RAD7 as a function of the sample thickness. For experimental validation of the technique an adobe building material sample was selected for measuring the thoron concentration at nineteen different sample thicknesses. Fitting the parameters of the model to the measurement results, both the generation rate and the diffusion length of thoron was estimated. We have also determined the optimal sample thickness for estimating the thoron generation rate from a single measurement. -- Highlights: • RAD7 is used for the determination of thoron generation rate (emanation). • The described model takes into account the thoron decay and attenuation. • The model describes well the experimental results. • A single point measurement method is offered at a determined sample thickness

  18. Static telescope aberration measurement using lucky imaging techniques

    Science.gov (United States)

    López-Marrero, Marcos; Rodríguez-Ramos, Luis Fernando; Marichal-Hernández, José Gil; Rodríguez-Ramos, José Manuel

    2012-07-01

    A procedure has been developed to compute static aberrations once the telescope PSF has been measured with the lucky imaging technique, using a nearby star close to the object of interest as the point source to probe the optical system. This PSF is iteratively turned into a phase map at the pupil using the Gerchberg-Saxton algorithm and then converted to the appropriate actuation information for a deformable mirror having low actuator number but large stroke capability. The main advantage of this procedure is related with the capability of correcting static aberration at the specific pointing direction and without the need of a wavefront sensor.

  19. The low-frequency sound power measuring technique for an underwater source in a non-anechoic tank

    Science.gov (United States)

    Zhang, Yi-Ming; Tang, Rui; Li, Qi; Shang, Da-Jing

    2018-03-01

    In order to determine the radiated sound power of an underwater source below the Schroeder cut-off frequency in a non-anechoic tank, a low-frequency extension measuring technique is proposed. This technique is based on a unique relationship between the transmission characteristics of the enclosed field and those of the free field, which can be obtained as a correction term based on previous measurements of a known simple source. The radiated sound power of an unknown underwater source in the free field can thereby be obtained accurately from measurements in a non-anechoic tank. To verify the validity of the proposed technique, a mathematical model of the enclosed field is established using normal-mode theory, and the relationship between the transmission characteristics of the enclosed and free fields is obtained. The radiated sound power of an underwater transducer source is tested in a glass tank using the proposed low-frequency extension measuring technique. Compared with the free field, the radiated sound power level of the narrowband spectrum deviation is found to be less than 3 dB, and the 1/3 octave spectrum deviation is found to be less than 1 dB. The proposed testing technique can be used not only to extend the low-frequency applications of non-anechoic tanks, but also for measurement of radiated sound power from complicated sources in non-anechoic tanks.

  20. Measurement of scintillation decay curves by a single photon counting technique

    International Nuclear Information System (INIS)

    Noguchi, Tsutomu

    1978-01-01

    An improved apparatus suitable for the measurement of spectroscopic scintillation decay curves has been developed by combination of a single photon counting technique and a delayed coincidence method. The time resolution of the apparatus is improved up to 1.16 nsec (FWHM), which is obtained from the resolution function of the system for very weak Cherenkov light flashes. Systematic measurement of scintillation decay curves is made for liquid and crystal scintillators including PPO-toluene, PBD-xylene, PPO-POPOP-toluene, anthracene and stilbene. (auth.)

  1. Flash fluorescence with indocyanine green videoangiography to identify the recipient artery for bypass with distal middle cerebral artery aneurysms: operative technique.

    Science.gov (United States)

    Rodríguez-Hernández, Ana; Lawton, Michael T

    2012-06-01

    Distal middle cerebral artery (MCA) aneurysms frequently have nonsaccular morphology that necessitates trapping and bypass. Bypasses can be difficult because efferent arteries lie deep in the opercular cleft and may not be easily identifiable. We introduce the "flash fluorescence" technique, which uses videoangiography with indocyanine green (ICG) dye to identify an appropriate recipient artery on the cortical surface for the bypass, enabling a more superficial and easier anastomosis. Flash fluorescence requires 3 steps: (1) temporary clip occlusion of the involved afferent artery; (2) videoangiography demonstrating fluorescence in uninvolved arteries on the cortical surface; and (3) removal of the temporary clip with flash fluorescence in the involved efferent arteries on the cortical surface, thereby identifying a recipient. Alternatively, temporary clips can occlude uninvolved arteries, and videoangiography will demonstrate initial fluorescence in efferent arteries during temporary occlusion and flash fluorescence in uninvolved arteries during reperfusion. From a consecutive series of 604 MCA aneurysms treated microsurgically, 22 (3.6%) were distal aneurysms and 11 required a bypass. The flash fluorescence technique was used in 3 patients to select the recipient artery for 2 superficial temporal artery-to-MCA bypasses and 1 MCA-MCA bypass. The correct recipient was selected in all cases. The flash fluorescence technique provides quick, reliable localization of an appropriate recipient artery for bypass when revascularization is needed for a distal MCA aneurysm. This technique eliminates the need for extensive dissection of the efferent artery and enables a superficial recipient site that makes the anastomosis safer, faster, and less demanding.

  2. Optical Measurement Techniques Innovations for Industry and the Life Sciences

    CERN Document Server

    Peiponen, Kai-Erik; Priezzhev, Alexander V

    2009-01-01

    Devoted to novel optical measurement techniques that are applied both in industry and life sciences, this book contributes a fresh perspective on the development of modern optical sensors. These sensors are often essential in detecting and controlling parameters that are important for both industrial and biomedical applications. The book provides easy access for beginners wishing to gain familiarity with the innovations of modern optics.

  3. Nondestructive hall coefficient measurements using ACPD techniques

    Science.gov (United States)

    Velicheti, Dheeraj; Nagy, Peter B.; Hassan, Waled

    2018-04-01

    Hall coefficient measurements offer great opportunities as well as major challenges for nondestructive materials characterization. The Hall effect is produced by the magnetic Lorentz force acting on moving charge carriers in the presence of an applied magnetic field. The magnetic perturbation gives rise to a Hall current that is normal to the conduction current but does not directly perturb the electric potential distribution. Therefore, Hall coefficient measurements usually exploit the so-called transverse galvanomagnetic potential drop effect that arises when the Hall current is intercepted by the boundaries of the specimen and thereby produce a measurable potential drop. In contrast, no Hall potential is produced in a large plate in the presence of a uniform normal field at quasi-static low frequencies. In other words, conventional Hall coefficient measurements are inherently destructive since they require cutting the material under tests. This study investigated the feasibility of using alternating current potential drop (ACPD) techniques for nondestructive Hall coefficient measurements in plates. Specifically, the directional four-point square-electrode configuration is investigated with superimposed external magnetic field. Two methods are suggested to make Hall coefficient measurements in large plates without destructive machining. At low frequencies, constraining the bias magnetic field can replace constraining the dimensions of the specimen, which is inherently destructive. For example, when a cylindrical permanent magnet is used to provide the bias magnetic field, the peak Hall voltage is produced when the diameter of the magnet is equal to the diagonal of the square ACPD probe. Although this method is less effective than cutting the specimen to a finite size, the loss of sensitivity is less than one order of magnitude even at very low frequencies. In contrast, at sufficiently high inspection frequencies the magnetic field of the Hall current induces a

  4. A simple technique for measuring buoyant weight increment of entire, transplanted coral colonies in the field.

    Science.gov (United States)

    Herler, Jürgen; Dirnwöber, Markus

    2011-10-31

    Estimating the impacts of global and local threats on coral reefs requires monitoring reef health and measuring coral growth and calcification rates at different time scales. This has traditionally been mostly performed in short-term experimental studies in which coral fragments were grown in the laboratory or in the field but measured ex situ. Practical techniques in which growth and measurements are performed over the long term in situ are rare. Apart from photographic approaches, weight increment measurements have also been applied. Past buoyant weight measurements under water involved a complicated and little-used apparatus. We introduce a new method that combines previous field and laboratory techniques to measure the buoyant weight of entire, transplanted corals under water. This method uses an electronic balance fitted into an acrylic glass underwater housing and placed atop of an acrylic glass cube. Within this cube, corals transplanted onto artificial bases can be attached to the balance and weighed at predetermined intervals while they continue growth in the field. We also provide a set of simple equations for the volume and weight determinations required to calculate net growth rates. The new technique is highly accurate: low error of weight determinations due to variation of coral density (corals. We outline a transplantation technique for properly preparing corals for such long-term in situ experiments and measurements.

  5. Calibration technique for radiation measurements in vacuum ultraviolet - soft x-ray region

    International Nuclear Information System (INIS)

    Mizui, Jun-ichi

    1986-05-01

    This is a collection of the papers presented at the workshop on ''Calibration Technique for Radiation Measurements in Vacuum Ultraviolet - Soft X-ray Region'' held at the Institute of Plasma Physics, Nagoya University, on December 19 - 20, 1985, under the Collaborating Research Program at the Institute. The following topics were discussed at the workshop: the needs for the calibration of plasma diagnostic devices, present status of the calibration technique, use of the Synchrotron Orbit Radiations for radiometry, and others. (author)

  6. Measurement of histamine release from human lung tissue ex vivo by microdialysis technique

    DEFF Research Database (Denmark)

    Nissen, Dan; Petersen, Lars Jelstrup; Nolte, H

    1998-01-01

    OBJECTIVE AND DESIGN: Currently no method is available for measurement of mediator release from intact human lung. In this study, a microdialysis technique was used to measure histamine release from mast cells in human lung tissue ex vivo. MATERIAL: Microdialysis fibers of 216 microm were inserted...... responses were observed but data could be reproduced within individual donors. Monocyte chemoattractant protein-1, a potent basophil secretagogue, did not induce histamine release in lung tissue which indicated mast cells to be the histamine source. Substance P did not release histamine in the lung tissue....... CONCLUSIONS: The microdialysis technique allowed measurements of histamine release from mast cells in intact lung ex vivo. The method may prove useful since a number of experiments can be performed in a few hours in intact lung tissue without any dispersion or enzymatic treatment....

  7. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    Science.gov (United States)

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  8. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  9. Application of PNA-technique for the measurement of multi-phase flow

    International Nuclear Information System (INIS)

    Loevhoeiden, G.; Andersen, E.; Garder, K.; Rambaek, J.P.

    1986-09-01

    The pulsed neutron activation (PNA) technique is proposed for multi-phase flow monitoring of hydrocarbons. The reactions 12 C(n,p) 12 B and 12 C(n,n') 12 C both yeld 4.4 MeV in the form of gamma radiation as a measure of carbon content. Intensity measurement of the 4.4 MeV gamma line gives a measure of the carbon content in the irradiation zone. By use of a pulsed neutron source, an estimation of the carbon content time variation is possible. In the presence of sulphur in petroleum, the reaction 34 S(n,p) 34 P offers a better possibility for flow rate determination

  10. Tracer technique for measuring specific activity of 63 Ni, using 4πβ-γ

    International Nuclear Information System (INIS)

    Iwahara, A.

    1979-01-01

    The specific activity of a 6 3 Ni solution has been measured by an efficiency tracer technique using a 4 π β - γ coincidence system. 6 3 Ni was chosen. Because it's a very low energy pure beta emitter. Due to chemical compatibility and beta spectral shapes, 6 0 Co has been chosen as tracer. In the determination of 6 3 Ni, the specific activity. As the efficiency tracer techniques requires a previous knowledge of tracer activity, this has been measured by a conventional 4 π β -γ coincidence method. (author)

  11. UF6 Density and Mass Flow Measurements for Enrichment Plants using Acoustic Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Good, Morris S.; Smith, Leon E.; Warren, Glen A.; Jones, Anthony M.; Ramuhalli, Pradeep; Roy, Surajit; Moran, Traci L.; Denslow, Kayte M.; Longoni, Gianluca

    2017-09-01

    A key enabling capability for enrichment plant safeguards being considered by the International Atomic Energy Agency (IAEA) is high-accuracy, noninvasive, unattended measurement of UF6 gas density and mass flow rate. Acoustic techniques are currently used to noninvasively monitor gas flow in industrial applications; however, the operating pressures at gaseous centrifuge enrichment plants (GCEPs) are roughly two orders magnitude below the capabilities of commercial instrumentation. Pacific Northwest National Laboratory is refining acoustic techniques for estimating density and mass flow rate of UF6 gas in scenarios typical of GCEPs, with the goal of achieving 1% measurement accuracy. Proof-of-concept laboratory measurements using a surrogate gas for UF6 have demonstrated signatures sensitive to gas density at low operating pressures such as 10–50 Torr, which were observed over the background acoustic interference. Current efforts involve developing a test bed for conducting acoustic measurements on flowing SF6 gas at representative flow rates and pressures to ascertain the viability of conducting gas flow measurements under these conditions. Density and flow measurements will be conducted to support the evaluation. If successful, the approach could enable an unattended, noninvasive approach to measure mass flow in unit header pipes of GCEPs.

  12. Measurement of void fractions by nuclear techniques; Medicion de fracciones de vacio por tecnicas nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez G, A.; Vazquez G, J.; Diaz H, C.; Salinas R, G.A. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    In this work it is done a general analysis of those techniques used to determine void fractions and it is chosen a nuclear technique to be used in the heat transfer circuit of the Physics Department of the Basic Sciences Management. The used methods for the determination of void fractions are: radioactive absorption, acoustic techniques, average velocity measurement, electromagnetic flow measurement, optical methods, oscillating absorption, nuclear magnetic resonance, relation between pressure and flow oscillation, infrared absorption methods, sound neutron analysis. For the case of this work it will be treated about the radioactive absorption method which is based in the gamma rays absorption. (Author)

  13. Objective Assessment of Sunburn and Minimal Erythema Doses: Comparison of Noninvasive In Vivo Measuring Techniques after UVB Irradiation

    Directory of Open Access Journals (Sweden)

    Kuo-Sheng Cheng

    2010-01-01

    Full Text Available Military personnel movement is exposed to solar radiation and sunburn is a major problem which can cause lost workdays and lead to disciplinary action. This study was designed to identify correlation parameters in evaluating in vivo doses and epidermis changes following sunburn inflammation. Several noninvasive bioengineering techniques have made objective evaluations possible. The volar forearms of healthy volunteers (n=20, 2 areas, 20 mm in diameter, were irradiated with UVB 100 mj/cm2 and 200 mj/cm2, respectively. The skin changes were recorded by several monitored techniques before and 24 hours after UV exposures. Our results showed that chromameter a∗ value provides more reliable information and can be adopted with mathematical model in predicting the minimal erythema dose (MED which showed lower than visual assessment by 10 mj/cm2 (Pearson correlation coefficient ℑ=0.758. A more objective measure for evaluation of MED was established for photosensitive subjects' prediction and sunburn risks prevention.

  14. Measurement of viscosity as a means to identify irradiated food

    International Nuclear Information System (INIS)

    Nuernberger, E.; Heide, L.; Boegl, K.W.

    1990-01-01

    The measurement of viscosity is a simple method to identify previous irradiation of some kinds of spices and foods, at least in combination with other methods. A possible change of the soaking capacity was examined up to a storage period of 18 months after irradiation of black pepper, white pepper, cinnamon, ginger and onion powder with a radiation dose of 10 kGy each. After irradiation, either increased or decreased viscosity values were measured; the results showed, also after the 18-months-storage period, considerable differences of the viscosity behaviour in non-irradiated and irradiated samples. The time of storage had no effect to the individual viscosity values, so that this method could also be applied to the examined spices after a longer storage period. (orig.) With 51 figs., 25 tabs [de

  15. New autocorrelation technique for the IR FEL optical pulse width measurements

    Energy Technology Data Exchange (ETDEWEB)

    Amirmadhi, F.; Brau, K.A.; Becker, C. [Vanderbilt Univ., Nashville, TN (United States)] [and others

    1995-12-31

    We have developed a new technique for the autocorrelation measurement of optical pulse width at the Vanderbilt University FEL center. This method is based on nonlinear absorption and transmission characteristics of semiconductors such as Ge, Te and InAs suitable for the wavelength range from 2 to over 6 microns. This approach, aside being simple and low cost, removes the phase matching condition that is generally required for the standard frequency doubling technique and covers a greater wavelength range per nonlinear material. In this paper we will describe the apparatus, explain the principal mechanism involved and compare data which have been acquired with both frequency doubling and two-photon absorption.

  16. Development of technique for quantifying gamma emitters in metal waste. New technique of precise and automatic measurements for confirmation of clearance level of metal waste

    International Nuclear Information System (INIS)

    Hattori, Takatoshi

    2002-01-01

    A New technique of precise and automatic measurements of gamma emitters in metal waste has been developed using 3D non-contact shape measurement and monte-carlo calculation techniques in order to confirm that specific radioactivity level of metal waste satisfies the clearance level and furthermore the surface contamination level of the metal waste is below the legal standard level. The technique can give a calibration factor every measurement target automatically and realize an automatic correction for reduction of background count rate in gamma measurements due to self-shield effect of the measurement target. The accuracy of the present method has been made clear using mock-metal wastes with various types of shape, number and size. Assuming the goal of the detection limit for practical use is 25OBq in radioactivity, a concept of the practical gamma monitor has been designed so as to be able to confirm both the clearance level and surface contamination level simultaneously and to cope with the metal waste at a speed of 2-10 ton a day. (author)

  17. Comparative study of elemental mercury flux measurement techniques over a Fennoscandian boreal peatland

    Science.gov (United States)

    Osterwalder, S.; Sommar, J.; Åkerblom, S.; Jocher, G.; Fritsche, J.; Nilsson, M. B.; Bishop, K.; Alewell, C.

    2018-01-01

    Quantitative estimates of the land-atmosphere exchange of gaseous elemental mercury (GEM) are biased by the measurement technique employed, because no standard method or scale in space and time are agreed upon. Here we present concurrent GEM exchange measurements over a boreal peatland using a novel relaxed eddy accumulation (REA) system, a rectangular Teflon® dynamic flux chamber (DFC) and a DFC designed according to aerodynamic considerations (Aero-DFC). During four consecutive days the DFCs were placed alternately on two measurement plots in every cardinal direction around the REA sampling mast. Spatial heterogeneity in peat surface characteristics (0-34 cm) was identified by measuring total mercury in eight peat cores (57 ± 8 ng g-1, average ± SE), vascular plant coverage (32-52%), water table level (4.5-14.1 cm) and dissolved gaseous elemental mercury concentrations (28-51 pg L-1) in the peat water. The GEM fluxes measured by the DFCs showed a distinct diel pattern, but no spatial difference in the average fluxes was detected (ANOVA, α = 0.05). Even though the correlation between the Teflon® DFC and Aero-DFC was significant (r = 0.76, p design is in agreement for cumulative flux estimates with the Aero-DFC, which incorporates the effect of atmospheric turbulence. The comparison was performed over a fetch with spatially rather homogenous GEM flux dynamics under fairly consistent weather conditions, minimizing the effect of weather influence on the data from the three measurement systems. However, in complex biomes with heterogeneous surface characteristics where there can be large spatial variability in GEM gas exchange, the small footprint of chambers (<0.2 m2) makes for large coefficients of variation. Thus many chamber measurement replications are needed to establish a credible biome GEM flux estimate, even for a single point in time. Dynamic flux chambers will, however, be able to resolve systematic differences between small scale features, such as

  18. Atmospheric measurements of hydroperoxides and aldehydes during field campaigns : new results due to improvement of measurements techniques

    Science.gov (United States)

    François, S.; Sowka, I.; Poulain, L.; Monod, A.; Wortham, H.

    2003-04-01

    Hydroperoxides and aldehydes are considered as atmospheric reservoirs of OH, HO_2 and RO_2 radicals and can reflect the oxidizing levels of the atmosphere. They are considered as important gas phase photo-oxidants present in the atmosphere. However, the atmospheric role of these compounds can vary from one species to another, therefore it is essential to investigate their measurement and speciation in the atmosphere. Atmospheric measurements were realized during two different field campaigns in the Marseilles area (France). Hydroperoxides were trapped in aqueous phase, with a glass coil and analyzed by HPLC/fluorescence detector with post column derivatization. Aldehydes were trapped in a liquid phase containing 2-4 DNPH, with a mist chamber and analyzed by HPLC/UV. The analytical techniques provided individual separation and quantification of seven hydroperoxides (hydrogen peroxide, hydroxymethyl hydroperoxide, bis(hydroxymethyl) peroxide, 1-hydroxyethyl hydroperoxide, methyl hydroperoxide, ethyl hydroperoxide and peroxyacetic acid) and eleven volatile aldehydes (formaldehyde, acetaldehyde, acrolein, acetone, propionaldehyde, crotonaldehyde, butyraldehyde, benzaldehyde, glyoxal, valeraldehyde and methylglyoxal). The first field campaign was part of the ESCOMPTE project (June 4th to July 16th 2001). During this campaign five different sampling sites, at low altitudes (<= 285 m), were investigated (maritime, urban, sub-industrial, biogenic and rural sites) and atmospheric measurements were realized during photochemical air pollution events. The second field campaign was part of the BOND project (July 2nd to July 14th 2002). Atmospheric measurements of hydroperoxides were carried out on one biogenic site, at altitude 690 m. The measurement system was improved allowing online sampling and analysis. During these field campaigns collection efficiencies were better than 96% for hydroperoxides, and from 78% to 96% for aldehydes. Detection limits were between 7,3× 10-3

  19. New Active Optical Technique Developed for Measuring Low-Earth-Orbit Atomic Oxygen Erosion of Polymers

    Science.gov (United States)

    Banks, Bruce A.; deGroh, Kim K.; Demko, Rikako

    2003-01-01

    Polymers such as polyimide Kapton (DuPont) and Teflon FEP (DuPont, fluorinated ethylene propylene) are commonly used spacecraft materials because of desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low-Earth-orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft performance and durability. It is, therefore, important to understand the atomic oxygen erosion yield E (the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is a passive technique based on mass-loss measurements of samples exposed to LEO atomic oxygen during a space flight experiment. There are certain disadvantages to this technique. First, because it is passive, data are not obtained until after the flight is completed. Also, obtaining the preflight and postflight mass measurements is complicated by the fact that many polymers absorb water and, therefore, the mass change due to water absorption can affect the E data. This is particularly true for experiments that receive low atomic oxygen exposures or for samples that have a very low E. An active atomic oxygen erosion technique based on optical measurements has been developed that has certain advantages over the mass-loss technique. This in situ technique can simultaneously provide the erosion yield data on orbit and the atomic oxygen exposure fluence, which is needed for erosion yield determination. In the optical technique, either sunlight or artificial light can be used to measure the erosion of semitransparent or opaque polymers as a result of atomic oxygen attack. The technique is simple and adaptable to a rather wide range of polymers, providing that they have a sufficiently high optical absorption coefficient. If one covers a photodiode with a

  20. Review of RDC Soft Computing Techniques for Accurate Measurement of Resolver Rotor Angle

    Directory of Open Access Journals (Sweden)

    Chandra Mohan Reddy Sivappagari

    2013-03-01

    Full Text Available A resolver is a position sensor or transducer that measures the instantaneous angular position of the rotating shaft to which it is attached. Resolver produces two amplitude modulated signals; SIN and COS as output signals. These two signals need to be demodulated and converted to digital signals before they can be used for control. There are several techniques available in the literature to measure the rotor shaft angle. This paper focuses on the design of both hardware and software based resolver to digital converter (RDC techniques available in the literature. This literature review helps the researchers to know about all these methods and plan future work on RDCs to improve the angle tracking performance.

  1. Development of self-calibration techniques for on-wafer and fixtured measurements: a novel approach

    OpenAIRE

    Pradell i Cara, Lluís; Purroy Martín, Francesc; Cáceres, M.

    1992-01-01

    Network Analyzer self-calibration techniques - TRL, LMR, TAR- are developed, implemented and compared in several transmission media. A novel LMR (Line-Match-Reflect) technique based on known LINE and REFLECT Standards, is proposed and compared to conventional LMR (based on known LINE and MATCH Standards) and other techniques (TRL, TAR). They are applied to on-wafer S-parameter measurement as well as to coaxial, waveguide and microstrip media. Experimental results up to 40 GHz are presented. ...

  2. Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings.

    Science.gov (United States)

    Berk, Thomas A; Yang, Patrick T; Chan, Clara C

    2016-10-01

    To compare intraocular pressure (IOP) measurement using the Goldmann applanation tonometry (GAT) without fluorescein, with fluorescein strips, with fluorescein droplets, and IOP measurement with Tono-Pen Avia (TPA). This was a prospective comparative clinical analysis. It was performed in clinical practice. The study population consisted of 40 volunteer patients, 1 eye per patient. All patients who were 18 years and older having routine ophthalmological examination were eligible to participate. Active corneal abrasions and/or ulcers, previous glaucoma surgery, or prostheses interfering with GAT measurement were excluded. GAT IOP was measured first without fluorescein, then with fluorescein strip, then with fluorescein droplet, and finally with the TPA device. The main outcome measure was central corneal IOP. Mean±SD IOP measurements for GAT without fluorescein, with fluorescein strip, with fluorescein droplet, and for TPA groups were 12.65±3.01, 14.70±2.82, 15.78±2.64, and 16.33±3.08 mm Hg, respectively. Repeated-measures analysis of variance corrected with the Greenhouse-Geisser estimate ([Latin Small Letter Open E]=0.732) showed that measuring technique had a significant effect on IOP measurements (F2.20,85.59=34.66, P<0.001). The pairwise post hoc testing showed statistically significant mean differences (P≤0.001) between all techniques except when GAT with fluorescein droplet was compared with TPA (P=0.222). The Bland-Altman analyses showed 95% limits of agreement maximum potential discrepancies in measurement ranging from 5.89 mm Hg in the GAT with fluorescein strip versus droplet compared with 11.83 mm Hg in the GAT with fluorescein strip versus TPA comparison. IOP measurement technique significantly impacted the values obtained. The ophthalmologist should ensure consistent measurement technique to minimize variability when following patients.

  3. Measurement of velocity field in pipe with classic twisted tape using matching refractive index technique

    Energy Technology Data Exchange (ETDEWEB)

    Song, Min Seop; Park, So Hyun; Kim, Eung Soo [Seoul National Univ., Seoul (Korea, Republic of)

    2014-10-15

    Many researchers conducted experiments and numerical simulations to measure or predict a Nusselt number or a friction factor in a pipe with a twisted tape while some other studies focused on the heat transfer performance enhancement using various twisted tape configurations. However, since the optical access to the inner space of a pipe with a twisted tape was limited, the detailed flow field data were not obtainable so far. Thus, researchers mainly relied on the numerical simulations to obtain the data of the flow field. In this study, a 3D printing technique was used to manufacture a transparent test section for optical access. And also, a noble refractive index matching technique was used to eliminate optical distortion. This two combined techniques enabled to measure the velocity profile with Particle Image Velocimetry (PIV). The measured velocity field data can be used either to understand the fundamental flow characteristics around a twisted tape or to validate turbulence models in Computational Fluid Dynamics (CFD). In this study, the flow field in the test-section was measured for various flow conditions and it was finally compared with numerically calculated data. Velocity fields in a pipe with a classic twisted tape was measured using a particle image velocimetry (PIV) system. To obtain undistorted particle images, a noble optical technique, refractive index matching, was used and it was proved that high-quality image can be obtained from this experimental equipment. The velocity data from the PIV was compared with the CFD simulations.

  4. Measurement of velocity field in pipe with classic twisted tape using matching refractive index technique

    International Nuclear Information System (INIS)

    Song, Min Seop; Park, So Hyun; Kim, Eung Soo

    2014-01-01

    Many researchers conducted experiments and numerical simulations to measure or predict a Nusselt number or a friction factor in a pipe with a twisted tape while some other studies focused on the heat transfer performance enhancement using various twisted tape configurations. However, since the optical access to the inner space of a pipe with a twisted tape was limited, the detailed flow field data were not obtainable so far. Thus, researchers mainly relied on the numerical simulations to obtain the data of the flow field. In this study, a 3D printing technique was used to manufacture a transparent test section for optical access. And also, a noble refractive index matching technique was used to eliminate optical distortion. This two combined techniques enabled to measure the velocity profile with Particle Image Velocimetry (PIV). The measured velocity field data can be used either to understand the fundamental flow characteristics around a twisted tape or to validate turbulence models in Computational Fluid Dynamics (CFD). In this study, the flow field in the test-section was measured for various flow conditions and it was finally compared with numerically calculated data. Velocity fields in a pipe with a classic twisted tape was measured using a particle image velocimetry (PIV) system. To obtain undistorted particle images, a noble optical technique, refractive index matching, was used and it was proved that high-quality image can be obtained from this experimental equipment. The velocity data from the PIV was compared with the CFD simulations

  5. Physical and measuring principles of nuclear well logging techniques

    International Nuclear Information System (INIS)

    Loetzsch, U.; Winkler, R.

    1981-01-01

    Proceeding from the general task of nuclear geophysics as a special discipline of applied geophyscis, the essential physical problems of nuclear well logging techniques are considered. Particularly, the quantitative relationship between measured values and interesting geologic parameters to be determined are discussed taking into account internal and external perturbation parameters. Resulting from this study, the technological requirements for radiation sources and their shielding, for detectors, electronic circuits in logging tools, signal transmission by cable and recording equipment are derived, and explained on the basis of examples of gamma-gamma and neutron-neutron logging. (author)

  6. Efficient Isothermal Titration Calorimetry Technique Identifies Direct Interaction of Small Molecule Inhibitors with the Target Protein.

    Science.gov (United States)

    Gal, Maayan; Bloch, Itai; Shechter, Nelia; Romanenko, Olga; Shir, Ofer M

    2016-01-01

    Protein-protein interactions (PPI) play a critical role in regulating many cellular processes. Finding novel PPI inhibitors that interfere with specific binding of two proteins is considered a great challenge, mainly due to the complexity involved in characterizing multi-molecular systems and limited understanding of the physical principles governing PPIs. Here we show that the combination of virtual screening techniques, which are capable of filtering a large library of potential small molecule inhibitors, and a unique secondary screening by isothermal titration calorimetry, a label-free method capable of observing direct interactions, is an efficient tool for finding such an inhibitor. In this study we applied this strategy in a search for a small molecule capable of interfering with the interaction of the tumor-suppressor p53 and the E3-ligase MDM2. We virtually screened a library of 15 million small molecules that were filtered to a final set of 80 virtual hits. Our in vitro experimental assay, designed to validate the activity of mixtures of compounds by isothermal titration calorimetry, was used to identify an active molecule against MDM2. At the end of the process the small molecule (4S,7R)-4-(4-chlorophenyl)-5-hydroxy-2,7-dimethyl-N-(6-methylpyridin-2-yl)-4,6,7,8 tetrahydrIoquinoline-3-carboxamide was found to bind MDM2 with a dissociation constant of ~2 µM. Following the identification of this single bioactive compound, spectroscopic measurements were used to further characterize the interaction of the small molecule with the target protein. 2D NMR spectroscopy was used to map the binding region of the small molecule, and fluorescence polarization measurement confirmed that it indeed competes with p53.

  7. Super-ASSET: A technique for measuring and correcting accelerator structure misalignments at the SLC

    International Nuclear Information System (INIS)

    Decker, F.J.; Assmann, R.; Minty, M.G.; Raimondi, P.; Stupakov, G.

    1998-07-01

    Transverse wakefield kicks from misaligned accelerating structures in the SLC linac contribute significantly to emittance growth. If these kicks could be measured directly, it would be possible to align and/or steer the beam to a kick-free trajectory. In the Accelerator Structure Test Facility at SLAC, ASSET, the kicks due to a drive bunch are measured with a witness bunch at varying bunch separations. In ASSET, the first bunch is discarded and only the second bunch is measured. Super-ASSET is an extension of this technique where both bunches are accelerated down the entire linac together and a sum trajectory of both bunches is measured with beam position monitors (BPMs). The trajectory of the second, kicked bunch can be calculated by subtracting the orbit of the first bunch, measured alone, from the sum trajectory. This paper discusses BPM response issues and the expected resolution of this technique together with alignment and steering strategies

  8. Highlights in radiation measuring technique's - Serial Micro Channel SMC 2100

    International Nuclear Information System (INIS)

    Kandler, M.; Hoffmann, Ch.

    2002-01-01

    The Serial Micro Channel SMC 2100 offers an ''intelligent stand alone'' electronics for the radiation measuring technique's. First it is designed of being connected to a serial interface RS232 of a PC. With a RS485 serial interface on a PC, a network structure can be generated. It has all functional modules which are necessary for the measurement of detector signals. Hence it is possible to directly connect any detector for radiation measurement to a PC, laptop, or notebook. All variations can be operated without PC support too. It has a modular structure and consists of two blocks, the functional modules and the basic modules. The Serial Micro Channel SMC 2100 may be directly coupled to a detector, which therefore makes the realisation of an ''intelligent radiation detector'' with serial link RS232 or RS485. (orig.)

  9. Implant Monitoring Measurements On Ultra Shallow Implants Before And After Anneal Using Photomodulated Reflection And Junction Photovoltage Measurement Techniques

    Science.gov (United States)

    Tallian, M.; Pap, A.; Mocsar, K.; Somogyi, A.; Nadudvari, Gy.; Kosztka, D.; Pavelka, T.

    2011-01-01

    Ultra shallow junctions are becoming widely used in the micro- and nanoelectronic devices, and novel measurement methods are needed to monitor the manufacturing processes. Photomodulated Reflection measurements before anneal and Junction Photovoltage-based sheet resistance measurements after anneal are non-contact, nondestructive techniques suitable for characterizing both the implantation and the annealing process. Tests verify that these methods are consistent with each other and by using them together, defects originating in the implantation and anneal steps can be separated.

  10. Book Review: Placing the Suspect behind the Keyboard: Using Digital Forensics and Investigative Techniques to Identify Cybercrime Suspects

    Directory of Open Access Journals (Sweden)

    Thomas Nash

    2013-06-01

    Full Text Available Shavers, B. (2013. Placing the Suspect behind the Keyboard: Using Digital Forensics and Investigative Techniques to Identify Cybercrime Suspects. Waltham, MA: Elsevier, 290 pages, ISBN-978-1-59749-985-9, US$51.56. Includes bibliographical references and index.Reviewed by Detective Corporal Thomas Nash (tnash@bpdvt.org, Burlington Vermont Police Department, Internet Crime against Children Task Force. Adjunct Instructor, Champlain College, Burlington VT.In this must read for any aspiring novice cybercrime investigator as well as the seasoned professional computer guru alike, Brett Shaver takes the reader into the ever changing and dynamic world of Cybercrime investigation.  Shaver, an experienced criminal investigator, lays out the details and intricacies of a computer related crime investigation in a clear and concise manner in his new easy to read publication, Placing the Suspect behind the Keyboard. Using Digital Forensics and Investigative techniques to Identify Cybercrime Suspects. Shaver takes the reader from start to finish through each step of the investigative process in well organized and easy to follow sections, with real case file examples to reach the ultimate goal of any investigation: identifying the suspect and proving their guilt in the crime. Do not be fooled by the title. This excellent, easily accessible reference is beneficial to both criminal as well as civil investigations and should be in every investigator’s library regardless of their respective criminal or civil investigative responsibilities.(see PDF for full review

  11. Proton current measurements using the prompt gamma ray diagnostic technique

    International Nuclear Information System (INIS)

    Leeper, R.J.; Burns, E.J.T.; Johnson, D.J.; McMurtry, W.M.

    1981-01-01

    Prompt gamma ray signals from the nuclear reaction 7 Li(p,γ) 8 Be have been used to make time resolved proton current measurements. In these measurements, the proton beam was allowed to strike cylindrical thick lithium metal targets. The time integrated proton current was measured using gamma activation of copper via the reaction 63 Cu(γ,n) 62 Cu(β+). The positron activity of the copper sample was easily measured using coincidence counting techniques. The number of 62 Cu atoms produced per proton incident on a thick Li metal target was determined with separate calibration runs performed on the Sandia 2.5 MeV Van de Graaff accelerator. The time history of the prompt gamma production was measured using six EGG NPM-54 scintillator photomultiplier combinations shielded by 96.5 cm of concrete and 5.1 cm of Pb. The use of six scintillator photomultiplier combinations was necessary to increase the statistical precision of the data. The normalization of the prompt gamma time history data with the total time integrated proton-current measurement yielded the absolute time resolved proton current on target. Data from runs performed on the Sandia Proto I accelerator will be presented

  12. A computational technique to measure fracture callus in radiographs.

    Science.gov (United States)

    Lujan, Trevor J; Madey, Steven M; Fitzpatrick, Dan C; Byrd, Gregory D; Sanderson, Jason M; Bottlang, Michael

    2010-03-03

    Callus formation occurs in the presence of secondary bone healing and has relevance to the fracture's mechanical environment. An objective image processing algorithm was developed to standardize the quantitative measurement of periosteal callus area in plain radiographs of long bone fractures. Algorithm accuracy and sensitivity were evaluated using surrogate models. For algorithm validation, callus formation on clinical radiographs was measured manually by orthopaedic surgeons and compared to non-clinicians using the algorithm. The algorithm measured the projected area of surrogate calluses with less than 5% error. However, error will increase when analyzing very small areas of callus and when using radiographs with low image resolution (i.e. 100 pixels per inch). The callus size extracted by the algorithm correlated well to the callus size outlined by the surgeons (R2=0.94, p<0.001). Furthermore, compared to clinician results, the algorithm yielded results with five times less inter-observer variance. This computational technique provides a reliable and efficient method to quantify secondary bone healing response. Copyright 2009 Elsevier Ltd. All rights reserved.

  13. Investigations of some rock stress measuring techniques and the stress field in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Hanssen, Tor Harald

    1998-12-31

    Rock stresses are important to the safe construction and operation of all man-made structures in rock, whether In mining, civil or petroleum engineering. The crucial issue is their relative magnitude and orientation. This thesis develops equipment and methods for further rock stress assessment and reevaluates existing overcoring rock stress measurements, and relates this information to the present geological setting. Both laboratory work and field work are involved. In the field, rock stresses are measured by the overcoring and the hydraulic fracturing technique. An observation technique for assessing likely high stresses is developed. The field data refer to several hydropower projects and to some offshore hydrocarbon fields. The principal sections are: (1) Tectonic setting in the western Fennoscandia, (2) Triaxial rock stress measurements by overcoring using the NTH cell (a strain gauge cell developed at the Norwegian technical university in Trondheim and based on the CSIR cell of the South African Council for Scientific and Industrial Research), (3) Laboratory testing of the NTH cell, (4) Quality ranking of stresses measured by the NTH cell, (4) Recalculated rock stresses and implications to the regional stress field, (5) Hydraulic fracturing stress measurements. 113 refs., 98 figs., 62 tabs.

  14. Investigations of some rock stress measuring techniques and the stress field in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Hanssen, Tor Harald

    1997-12-31

    Rock stresses are important to the safe construction and operation of all man-made structures in rock, whether In mining, civil or petroleum engineering. The crucial issue is their relative magnitude and orientation. This thesis develops equipment and methods for further rock stress assessment and reevaluates existing overcoring rock stress measurements, and relates this information to the present geological setting. Both laboratory work and field work are involved. In the field, rock stresses are measured by the overcoring and the hydraulic fracturing technique. An observation technique for assessing likely high stresses is developed. The field data refer to several hydropower projects and to some offshore hydrocarbon fields. The principal sections are: (1) Tectonic setting in the western Fennoscandia, (2) Triaxial rock stress measurements by overcoring using the NTH cell (a strain gauge cell developed at the Norwegian technical university in Trondheim and based on the CSIR cell of the South African Council for Scientific and Industrial Research), (3) Laboratory testing of the NTH cell, (4) Quality ranking of stresses measured by the NTH cell, (4) Recalculated rock stresses and implications to the regional stress field, (5) Hydraulic fracturing stress measurements. 113 refs., 98 figs., 62 tabs.

  15. Measurement of interfacial tension by use of pendant drop video techniques

    Science.gov (United States)

    Herd, Melvin D.; Thomas, Charles P.; Bala, Gregory A.; Lassahn, Gordon D.

    1993-09-01

    This report describes an instrument to measure the interfacial tension (IFT) of aqueous surfactant solutions and crude oil. The method involves injection of a drop of fluid (such as crude oil) into a second immiscible phase to determine the IFT between the two phases. The instrument is composed of an AT-class computer, optical cell, illumination, video camera and lens, video frame digitizer board, monitor, and software. The camera displays an image of the pendant drop on the monitor, which is then processed by the frame digitizer board and non-proprietary software to determine the IFT. Several binary and ternary phase systems were taken from the literature and used to measure the precision and accuracy of the instrument in determining IFT's. A copy of the software program is included in the report. A copy of the program on diskette can be obtained from the Energy Science and Technology Software Center, P.O. Box 1020, Oak Ridge, TN 37831-1020. The accuracy and precision of the technique and apparatus presented is very good for measurement of IFT's in the range from 72 to 10(exp -2) mN/m, which is adequate for many EOR applications. With modifications to the equipment and the numerical techniques, measurements of ultralow IFT's (less than 10(exp -3) mN/m) should be possible as well as measurements at reservoir temperature and pressure conditions. The instrument has been used at the Idaho National Engineering Laboratory to support the research program on microbial enhanced oil recovery. Measurements of IFT's for several bacterial supernatants and unfractionated acid precipitates of microbial cultures containing biosurfactants against medium to heavy crude oils are reported. These experiments demonstrate that the use of automated video imaging of pendant drops is a simple and fast method to reliably determine interfacial tension between two immiscible liquid phases, or between a gas and a liquid phase.

  16. Design and Development of Emittance Measurement Device by Using the Pepper-pot Technique

    Science.gov (United States)

    Pakluea, S.; Rimjaem, S.

    2017-09-01

    Transverse emittance of a charged particle beam is one of the most important properties that reveals the quality of the beam. It is related to charge density, transvers size and angular displacement of the beam in transverse phase space. There are several techniques to measure the transverse emittance value. One of practical methods is the pepper-pot technique, which can measure both horizontal and vertical emittance value in a single measurement. This research concentrates on development of a pepper-pot device to measure the transverse emittance of electron beam produced from an accelerator injector system, which consists of a thermionic cathode RF electron gun and an alpha magnet, at the Plasma and Beam Physics Research Facility, Chiang Mai University. Simulation of beam dynamics was conducted with programs PARMELA, ELEGANT and self-developed codes using C and MATLAB. The geometry, dimensions and location of the pepper-pot as well as its corresponding screen station position were included in the simulation. The result from this study will be used to design and develop a practical pepper-pot experimental station.

  17. Electric field measurement in the ionosphere using the time-of-flight technique

    International Nuclear Information System (INIS)

    Nakamura, Masato; Hayakawa, Hajime; Tsuruda, Koichiro

    1989-01-01

    The first successful electric field measurement in the ionosphere using the time-of-flight technique with a lithium ion beam was carried out on a S-520 sounding rocket launched from Kagoshima Space Center, Japan on January 15, 1987. The purpose of this experiment was to prove the validity of the time-of-flight technique when it is applied to the measurement of the dc electric field in the ionosphere. A time-coded ion beam was ejected from the rocket in the direction perpendicular to the Earth's magnetic field. The beam returned to the rocket twice per rocket spin when the initial beam direction was nearly perpendicular to the electric field. The electric field and the magnetic field were derived from the travel time of these return lithium ions. The accuracy of the electric field determination was ± 0.3 mV/m. The direction of the electric field was obtained from the direction of the returning ion beam after about one ion gyration. The main constituent of the measured electric field was a V x B field due to the rocket motion across the geomagnetic field. The ambient field was less than 1 mV/m. The magnetic field was measured with an accuracy of ± 2.7 nT in this experiment

  18. Beam profile measurements on the advanced test accelerator using optical techniques

    International Nuclear Information System (INIS)

    Chong, Y.P.; Kalibjian, R.; Cornish, J.P.; Kallman, J.S.; Donnelly, D.

    1986-01-01

    Beam current density profiles of ATA have been measured both spatially and temporally using a number of diagnostics. An extremely important technique involves measuring optical emissions from either a target foil inserted into the beam path or gas atoms and molecules excited by beam electrons. This paper describes the detection of the optical emission. A 2-D gated television camera with a single or dual micro-channel-plate (MCP) detector for high gain provides excellent spatial and temporal resolution. Measurements are routinely made with resolutions of 1 mm and 5 ns respectively. The optical line of sight allows splitting part of the signal to a streak camera or photometer for even higher time resolution

  19. Ultrasonic techniques for measuring physical properties of fluids in harsh environments

    Science.gov (United States)

    Pantea, Cristian

    Ultrasonic-based measurement techniques, either in the time domain or in the frequency domain, include a wide range of experimental methods for investigating physical properties of materials. This discussion is specifically focused on ultrasonic methods and instrumentation development for the determination of liquid properties at conditions typically found in subsurface environments (in the U.S., more than 80% of total energy needs are provided by subsurface energy sources). Such sensors require materials that can withstand harsh conditions of high pressure, high temperature and corrosiveness. These include the piezoelectric material, electrically conductive adhesives, sensor housings/enclosures, and the signal carrying cables, to name a few. A complete sensor package was developed for operation at high temperatures and pressures characteristic to geothermal/oil-industry reservoirs. This package is designed to provide real-time, simultaneous measurements of multiple physical parameters, such as temperature, pressure, salinity and sound speed. The basic principle for this sensor's operation is an ultrasonic frequency domain technique, combined with transducer resonance tracking. This multipurpose acoustic sensor can be used at depths of several thousand meters, temperatures up to 250 °C, and in a very corrosive environment. In the context of high precision measurement of sound speed, the determination of acoustic nonlinearity of liquids will also be discussed, using two different approaches: (i) the thermodynamic method, in which precise and accurate frequency domain sound speed measurements are performed at high pressure and high temperature, and (ii) a modified finite amplitude method, requiring time domain measurements of the second harmonic at room temperature. Efforts toward the development of an acoustic source of collimated low-frequency (10-150 kHz) beam, with applications in imaging, will also be presented.

  20. Measurement of liquid level in a natural circulation circuit using an ultrasonic technique

    International Nuclear Information System (INIS)

    Barbosa, Amanda Cardozo; Su, Jian

    2017-01-01

    The measurement by an ultrasonic technique of the water level in the expansion tank of the Natural Circulation Circuit (NCC) of the Experimental Thermo-Hydraulic Laboratory of the Institute of Nuclear Engineering is presented. In the single-phase NCC operation the water level in the expansion tank is stable. However, during the two-phase operation, oscillations occur in the water level due to temperature and vacuum fraction variations. Thus, the development of a technique that allows the measurement of these oscillations, will allow an estimation of the variation of the vacuum fraction of the circuit over time. The experimental set - up was performed on a test bench, using an ultrasonic transducer. The ultrasonic technique used is pulse-echo, in which the same transducer is the transmitter and receiver of the signal. The transducer-shoe assembly is part of an ultrasonic system consisting of an ultrasonic signal generating plate, transducers and a computer (PC) with a program in LabView to control the system. The program is able to calculate the transit time that the ultrasonic signals take to cross the tank base wall, the layer (level) of liquid and return to the transducer. Knowing the speed of the ultrasound in the wall and in the liquid it is possible to calculate the thickness of the wall and the height of the liquid. Measurements were made by filling the tank with a known volume of water and under varying temperature conditions, from room temperature to 90 deg C. The liquid heights are determined and the volume of water calculated by measuring the temperature with a digital thermometer. The volumes measured were highly accurate when compared to the known volumes

  1. Measurement techniques in dry-powdered processing of spent nuclear fuels

    International Nuclear Information System (INIS)

    Bowers, D. L.; Hong, J.-S.; Kim, H.-D.; Persiani, P. J.; Wolf, S. F.

    1999-01-01

    High-performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICPMS) detection, α-spectrometry (α-S), and γ-spectrometry (γ-S) were used for the determination of nuclide content in five samples excised from a high-burnup fuel rod taken from a pressurized water reactor (PWR). The samples were prepared for analysis by dissolution of dry-powdered samples. The measurement techniques required no separation of the plutonium, uranium, and fission products. The sample preparation and analysis techniques showed promise for in-line analysis of highly-irradiated spent fuels in a dry-powdered process. The analytical results allowed the determination of fuel burnup based on 148 Nd, Pu, and U content. A goal of this effort is to develop the HPLC-ICPMS method for direct fissile material accountancy in the dry-powdered processing of spent nuclear fuel

  2. Progress in nuclear measuring and experimental techniques by application of microelectronics. 1

    International Nuclear Information System (INIS)

    Meiling, W.

    1984-01-01

    In the past decade considerable progress has been made in nuclear measuring and experimental techniques by developing position-sensitive detector systems and widely using integrated circuits and microcomputers for data acquisition and processing as well as for automation of measuring processes. In this report which will be published in three parts those developments are reviewed and demonstrated on selected examples. After briefly characterizing microelectronics, the use of microelectronic elements for radiation detectors is reviewed. (author)

  3. Experimental program for development and evaluation of nondestructive assay techniques for plutonium holdup

    International Nuclear Information System (INIS)

    Brumbach, S.B.

    1977-05-01

    An outline is presented for an experimental program to develop and evaluate nondestructive assay techniques applicable to holdup measurement in plutonium-containing fuel fabrication facilities. The current state-of-the-art in holdup measurements is reviewed. Various aspects of the fuel fabrication process and the fabrication facility are considered for their potential impact on holdup measurements. The measurement techniques considered are those using gamma-ray counting, neutron counting, and temperature measurement. The advantages and disadvantages of each technique are discussed. Potential difficulties in applying the techniques to holdup measurement are identified. Experiments are proposed to determine the effects of such problems as variation in sample thickness, in sample distribution, and in background radiation. These experiments are also directed toward identification of techniques most appropriate to various applications. Also proposed are experiments to quantify the uncertainties expected for each measurement

  4. Development of a three-dimensional PIV measurement technique for the experimental study of air bubble collapse phenomena

    International Nuclear Information System (INIS)

    Yang, Y.H.; Hassan, Y.A.; Schmidl, W.D.

    1995-01-01

    Particle image velocimetry (PIV) is a quantitative flow measurement technique. The objective of this study is to develop a new three-dimensional PIV technique for the experimental study of air bubble collapse phenomena. A three-dimensional measurement technique is necessary since bubble collapse is a three-dimensional phenomenon. The investigation of the velocity flow field around a collapsing air bubble can provide detailed three-dimensional quantitative information to help improve the understanding of the related heat transfer processes

  5. Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles.

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Seo, Seung-Jun; Lim, Jae-Hong; Lee, Sang-Joon

    2015-03-06

    Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO2 microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO2 microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases.

  6. Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Seo, Seung-Jun; Lim, Jae-Hong; Lee, Sang-Joon

    2015-01-01

    Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO2 microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO2 microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases. PMID:25744850

  7. Measurement of spatial correlation functions using image processing techniques

    International Nuclear Information System (INIS)

    Berryman, J.G.

    1985-01-01

    A procedure for using digital image processing techniques to measure the spatial correlation functions of composite heterogeneous materials is presented. Methods for eliminating undesirable biases and warping in digitized photographs are discussed. Fourier transform methods and array processor techniques for calculating the spatial correlation functions are treated. By introducing a minimal set of lattice-commensurate triangles, a method of sorting and storing the values of three-point correlation functions in a compact one-dimensional array is developed. Examples are presented at each stage of the analysis using synthetic photographs of cross sections of a model random material (the penetrable sphere model) for which the analytical form of the spatial correlations functions is known. Although results depend somewhat on magnification and on relative volume fraction, it is found that photographs digitized with 512 x 512 pixels generally have sufficiently good statistics for most practical purposes. To illustrate the use of the correlation functions, bounds on conductivity for the penetrable sphere model are calculated with a general numerical scheme developed for treating the singular three-dimensional integrals which must be evaluated

  8. Technique charts for EC film: direct optical measurements to account for the effects of X-ray scatter

    International Nuclear Information System (INIS)

    Munro, Peter; Jordan, Kevin; Lewis, Craig; Heerema, Tim

    2001-01-01

    Purpose: To develop a method of measuring technique charts for enhanced contrast (EC) film, to demonstrate how X-ray scatter changes the response of EC film, and to generate technique charts for general use. Methods and Materials: We have developed a 'digital cassette' - consisting of a metal plate/phosphor screen, a light guide, a photodiode sensor, and an electrometer - that can be used to measure the light generated in the phosphor screen of the film cassette. In turn, these measurements can be used to generate technique charts for EC film. The digital cassette has been used to measure technique charts for 4-MV and 6-MV X-ray beams for a variety of different phantom thicknesses, field sizes, and phantom-to-cassette air gaps. Results and Discussion: We have observed that the signals generated in an ionization chamber located 9.4 cm behind a 30-cm-thick water-equivalent phantom increase by a factor of 1.9 when the field size is increased from 4x4 cm 2 to 40x40 cm 2 when irradiated by a 6-MV X-ray beam. However, the change in EC film response is a factor of 3.5 under the same conditions. Irradiations to optimally expose the EC film predicted by the digital cassette differ by up to 82% compared to those predicted by ion chamber measurements. Nevertheless, the technique charts measured using the digital cassette predict the response of the EC film to ±0.2 optical density. The overresponse of the EC film is most likely due to low-energy scattered photons, which interact with the high atomic number (Z=64) phosphor screen of the enhanced contrast localization cassette. Therefore, simple solutions, such as placing a high atomic number material above the enhanced contrast localization cassette, can reduce this contribution by scattered photons to the signal generated in the cassettes. Conclusions: We have developed a digital cassette that can make more accurate measurements of the technique charts for EC films. Our measurements show that under some conditions, X

  9. Comparison of activation cross section measurements and experimental techniques for fusion reactor technology. Summary report of the IAEA specialists' meeting held in St. Petersburg, Russia, 7 to 9 September 1994

    International Nuclear Information System (INIS)

    Pashchenko, A.B.

    1995-02-01

    The report contains the Summary of the IAEA Specialists' Meeting on ''Comparison of Activation Cross Section Measurements and Experimental Techniques for Fusion Reactor Technology''. The meeting was organized by the IAEA Nuclear Data Section (NDS) with co-operation and assistance of local organizers from the V.G. Khlopin Radium Institute, KRI, and held in St. Petersburg, Russia, from 7 to 9 September 1994. The aim of the meeting was to discuss and evaluate the preliminary results of the researches carried out in the framework of the international programme on Comparison of Activation Cross Section Measurements and Experimental Techniques for Fusion Reactor Technology coordinated by the IAEA Nuclear Data Section and to identify further measurements and actions of participating laboratories. The detailed conclusions and recommendations of the meeting are presented in Attachment 1 of the summary report. It was confirmed that for further comparison of experimental techniques the experimental groups at JAERI (Tokai, Japan), KRI (St. Petersburg, Russia), IPPE (Obninsk, Russia) and IEP (Debrecen, Hungary) will join in a collaborative program on comparing their measurement techniques and do measurements for reactions where discrepancies between their previous measurements exist. In cases where the JAERI results are the only existing data or deviate strongly from previous measurements, collaboration between KRI, IEP, IPPE and other institutions can consider measurements of these cross sections in order to clarify the situation. (author)

  10. Application of Electromagnetic Induction Technique to Measure the Void Fraction in Oil/Gas Two Phase Flow

    Science.gov (United States)

    Wahhab, H. A. Abdul; Aziz, A. R. A.; Al-Kayiem, H. H.; Nasif, M. S.; Reda, M. N.

    2018-03-01

    In this work, electromagnetic induction technique of measuring void fraction in liquid/gas fuel flow was utilized. In order to improve the electric properties of liquid fuel, an iron oxide Fe3O4 nanoparticles at 3% was blended to enhance the liquid fuel magnetization. Experiments have been conducted for a wide range of liquid and gas superficial velocities. From the experimental results, it was realized that there is an existing linear relationship between the void fraction and the measured electromotive force, when induction coils were connected in series for excitation coils, regardless of increase or decrease CNG bubbles distribution in liquid fuel flow. Therefore, it was revealed that the utilized method yielded quite reasonable account for measuring the void fraction, showing good agreement with the other available measurement techniques in the two-phase flow, and also with the published literature of the bubbly flow pattern. From the results of the present investigation, it has been proven that the electromagnetic induction is a feasible technique for the actual measurement of void fraction in a Diesel/CNG fuel flow.

  11. Relationship between alveolar bone measured by 125I absorptiometry with analysis of standardized radiographs: 2. Bjorn technique

    International Nuclear Information System (INIS)

    Ortman, L.F.; McHenry, K.; Hausmann, E.

    1982-01-01

    The Bjorn technique is widely used in periodontal studies as a standardized measure of alveolar bone. Recent studies have demonstrated the feasibility of using 125 I absorptiometry to measure bone mass. The purpose of this study was to compare 125 I absorptiometry with the Bjorn technique in detecting small sequential losses of alveolary bone. Four periodontal-like defects of incrementally increasing size were produced in alveolar bone in the posterior segment of the maxilla of a human skull. An attempt was made to sequentially reduce the amount of bone in 10% increments until no bone remained, a through and through defect. The bone remaining at each step was measured using 125 I absorptiometry. At each site the 125 I absorptiometry measurements were made at the same location by fixing the photon source to a prefabricated precision-made occlusal splint. This site was just beneath the crest and midway between the borders of two adjacent teeth. Bone loss was also determined by the Bjorn technique. Standardized intraoral films were taken using a custom-fitted acrylic clutch, and bone measurements were made from the root apex to coronal height of the lamina dura. A comparison of the data indicates that: (1) in early bone loss, less than 30%, the Bjorn technique underestimates the amount of loss, and (2) in advanced bone loss, more than 60% the Bjorn technique overestimates it

  12. An Integrated Approach to Change the Outcome Part II: Targeted Neuromuscular Training Techniques to Reduce Identified ACL Injury Risk Factors

    Science.gov (United States)

    Myer, Gregory D.; Ford, Kevin R.; Brent, Jensen L.; Hewett, Timothy E.

    2014-01-01

    Prior reports indicate that female athletes who demonstrate high knee abduction moments (KAMs) during landing are more responsive to neuromuscular training designed to reduce KAM. Identification of female athletes who demonstrate high KAM, which accurately identifies those at risk for noncontact anterior cruciate ligament (ACL) injury, may be ideal for targeted neuromuscular training. Specific neuromuscular training targeted to the underlying biomechanical components that increase KAM may provide the most efficient and effective training strategy to reduce noncontact ACL injury risk. The purpose of the current commentary is to provide an integrative approach to identify and target mechanistic underpinnings to increased ACL injury in female athletes. Specific neuromuscular training techniques will be presented that address individual algorithm components related to high knee load landing patterns. If these integrated techniques are employed on a widespread basis, prevention strategies for noncontact ACL injury among young female athletes may prove both more effective and efficient. PMID:22580980

  13. Comparison of global sensitivity analysis techniques and importance measures in PSA

    International Nuclear Information System (INIS)

    Borgonovo, E.; Apostolakis, G.E.; Tarantola, S.; Saltelli, A.

    2003-01-01

    This paper discusses application and results of global sensitivity analysis techniques to probabilistic safety assessment (PSA) models, and their comparison to importance measures. This comparison allows one to understand whether PSA elements that are important to the risk, as revealed by importance measures, are also important contributors to the model uncertainty, as revealed by global sensitivity analysis. We show that, due to epistemic dependence, uncertainty and global sensitivity analysis of PSA models must be performed at the parameter level. A difficulty arises, since standard codes produce the calculations at the basic event level. We discuss both the indirect comparison through importance measures computed for basic events, and the direct comparison performed using the differential importance measure and the Fussell-Vesely importance at the parameter level. Results are discussed for the large LLOCA sequence of the advanced test reactor PSA

  14. Validation of the actuator line/Navier Stokes technique using mexico measurements

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zhu, Wei Jun; Sørensen, Jens Nørkær

    2010-01-01

    This paper concerns the contribution of DTU MEK in the international research collaboration project (MexNext) within the framework of IEA Annex 29 to validate aerodynamic models or CFD codes using the existing measurements made in the previous EU funded projectMEXICO (Model Experiments in Control......This paper concerns the contribution of DTU MEK in the international research collaboration project (MexNext) within the framework of IEA Annex 29 to validate aerodynamic models or CFD codes using the existing measurements made in the previous EU funded projectMEXICO (Model Experiments...... in Controlled Conditions). The Actuator Line/Navier Stokes (AL/NS) technique developed at DTU is validated against the detailed MEXICO measurements. The AL/NS computations without the DNW wind tunnel with speeds of 10m/s, 15m/s and 24m/s. Comparisons of blade loading between computations and measurements show...

  15. An X-band waveguide measurement technique for the accurate characterization of materials with low dielectric loss permittivity

    Energy Technology Data Exchange (ETDEWEB)

    Allen, Kenneth W., E-mail: kenneth.allen@gtri.gatech.edu; Scott, Mark M.; Reid, David R.; Bean, Jeffrey A.; Ellis, Jeremy D.; Morris, Andrew P.; Marsh, Jeramy M. [Advanced Concepts Laboratory, Georgia Tech Research Institute, Atlanta, Georgia 30318 (United States)

    2016-05-15

    In this work, we present a new X-band waveguide (WR90) measurement method that permits the broadband characterization of the complex permittivity for low dielectric loss tangent material specimens with improved accuracy. An electrically long polypropylene specimen that partially fills the cross-section is inserted into the waveguide and the transmitted scattering parameter (S{sub 21}) is measured. The extraction method relies on computational electromagnetic simulations, coupled with a genetic algorithm, to match the experimental S{sub 21} measurement. The sensitivity of the technique to sample length was explored by simulating specimen lengths from 2.54 to 15.24 cm, in 2.54 cm increments. Analysis of our simulated data predicts the technique will have the sensitivity to measure loss tangent values on the order of 10{sup −3} for materials such as polymers with relatively low real permittivity values. The ability to accurately characterize low-loss dielectric material specimens of polypropylene is demonstrated experimentally. The method was validated by excellent agreement with a free-space focused-beam system measurement of a polypropylene sheet. This technique provides the material measurement community with the ability to accurately extract material properties of low-loss material specimen over the entire X-band range. This technique could easily be extended to other frequency bands.

  16. Measurements of low density, high velocity flow by electron beam fluorescence technique

    International Nuclear Information System (INIS)

    Soga, Takeo; Takanishi, Masaya; Yasuhara, Michiru

    1981-01-01

    A low density chamber with an electron gun system was made for the measurements of low density, high velocity (high Mach number) flow. This apparatus is a continuous running facility. The number density and the rotational temperature in the underexpanding free jet of nitrogen were measured along the axis of the jet by the electron beam fluorescence technique. The measurements were carried out from the vicinity of the exit of the jet to far downstream of the first Mach disk. Rotational nonequilibrium phenomena were observed in the hypersonic flow field as well as in the shock wave (Mach disk). (author)

  17. The transverse technique; a complementary approach to the measurement of first-trimester uterine artery Doppler.

    Science.gov (United States)

    Drouin, Olivier; Johnson, Jo-Ann; Chaemsaithong, Piya; Metcalfe, Amy; Huber, Janie; Schwarzenberger, Jill; Winters, Erin; Stavness, Lesley; Tse, Ada W T; Lu, Jing; Lim, Wan Teng; Leung, Tak Yeung; Bujold, Emmanuel; Sahota, Daljit; Poon, Liona C

    2017-10-04

    The objectives of this study were to 1) define the protocol for the first-trimester assessment of the uterine artery pulsatility index (UtA-PI) using the new transverse technique, 2) evaluate UtA-PI measured by the transverse approach versus that obtained by the conventional sagittal approach, and 3) determine if accelerated onsite training (both methods) of inexperienced sonographers can achieve reproducible UtA-PI measurements compared to that measured by an experienced sonographer. The study consists of 2 parts conducted in 2 centers (Part 1, Calgary, Canada and Part 2, Hong Kong). Part 1 Prospective observational study of women with singleton pregnancies between 11-13+6 weeks' gestation. UtA-PI measurements were performed using the 2 techniques (4 sonographers trained in both methods, 10 cases each) and measurement indices (PI), time required and subjective difficulty to obtain satisfactory measurements were compared. One sample t-test and Wilcoxon rank sign test was used when appropriate. Bland-Altman difference plots were used to assess measurement agreement, and intra-class correlation (ICC) was used to evaluate measurement reliability. A target plot was used to assess measures of central tendency and dispersion. Part 2 One experienced and three inexperienced sonographers prospectively measured the UtA-PI at 11-13+6 weeks' gestation in two groups of women (42 and 35, respectively), with singleton pregnancies using both approaches. Inexperienced sonographers underwent accelerated on-site training by the experienced sonographer. Measurement approach and sonographer order were on a random basis. ICC, Bland-Altman and Passing-Bablok analyses were performed to assess measurement agreement, reliability and effect of accelerated training. Part 1 We observed no difference in the mean time to acquire the measurements (Sagittal: 118 seconds vs Transverse: 106 seconds, p=0.38). The 4 sonographers reported the transverse technique was subjectively easier to perform (p=0

  18. Measurement of β/Λ ratio in IEA-R1 reactor using noise technique

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Kassar, E.

    1986-01-01

    The ratio β/Λ for the IEA-R1 reactor is obtained experimentally through the noise analysis technique. This technique is based on the determination of the power spectral density of the reactor neutron population, with the reactor in a subcritical state driven by a 'white' neutron source. A ratio β/Λ of 43,5 s -1 is estimated from the break frequency of the measured transfer function of the IEA-R1 reactor. (Author) [pt

  19. Measurement of Mixing Rate between Fuel Subchannels: Development of a new Experimental Technique

    International Nuclear Information System (INIS)

    Silin, Nicolas; Barbero, Jose; Bubach, Ernesto; Juanico, Luis

    2000-01-01

    A superficial heater of nickel applied over a ceramic substrate was designed and constructed, together with a system of high sensitivity to measure temperature differentials. The use of both techniques was evaluated and it might allow for the wider use of the method of differential thermal analysis to quantify the turbulent mixing between coupled hydraulic subchannels in fuel elements. Even more, the method presents important advantages as compared to the more complicated techniques known (laser Doppler anemometry)

  20. Measuring thermal conductivity of polystyrene nanowires using the dual-cantilever technique.

    Science.gov (United States)

    Canetta, Carlo; Guo, Samuel; Narayanaswamy, Arvind

    2014-10-01

    Thermal conductance measurements are performed on individual polystyrene nanowires using a novel measurement technique in which the wires are suspended between two bi-material microcantilever sensors. The nanowires are fabricated via electrospinning process. Thermal conductivity of the nanowire samples is found to be between 6.6 and 14.4 W m(-1) K(-1) depending on sample, a significant increase above typical bulk conductivity values for polystyrene. The high strain rates characteristic of electrospinning are believed to lead to alignment of molecular polymer chains, and hence the increase in thermal conductivity, along the axis of the nanowire.

  1. Two-phase flow void fraction measurement using gamma ray attenuation technique

    International Nuclear Information System (INIS)

    Silva, R.D. da.

    1985-01-01

    The present work deals with experimental void fraction measurements in two-phase water-nitrogen flow, by using a gamma ray attenuation technique. Several upward two-phase flow regimes in a vertical tube were simulated. The water flow was varied from 0.13 to 0.44 m 3 /h while the nitrogen flow was varied between 0.01 and 0.1 m 3 /h. The mean volumetric void fraction was determined based on the measured linear void fraction for each flow condition. The results were compared with other authors data and showed a good agreement. (author) [pt

  2. An attenuation measurement technique for rotating planar detector positron tomographs

    International Nuclear Information System (INIS)

    McNeil, P.A.; Julyan, P.J.; Parker, D.J.

    1997-01-01

    This paper presents a new attenuation measurement technique suitable for rotating planar detector positron tomographs. Transmission measurements are made using two unshielded positron-emitting line sources, one attached to the front face of each detector. Many of the scattered and accidental coincidences are rejected by including only those coincidences that form a vector passing within a predetermined distance of either line source. Some scattered and accidental coincidences are still included, which reduces the measured linear attenuation; in principle their contribution can be accurately estimated and subtracted, but in practice, when limited statistics are available (as is the case with the multi-wire Birmingham positron camera), this background subtraction unacceptably increases the noise. Instead an attenuation image having the correct features can be reconstructed from the measured projections. For objects containing only a few discrete linear attenuation coefficients, segmentation of this attenuation image reduces noise and allows the correct linear attenuation coefficients to be restored by renormalization. Reprojection through the segmented image may then provide quantitatively correct attenuation correction factors of sufficient statistical quality to correct for attenuation in PET emission images. (author)

  3. A simple technique for the measurement of 222Rn in soil gas using LLRDS

    International Nuclear Information System (INIS)

    Karunakara, N.

    2010-01-01

    The details of the technique of soil gas measurement using LLRDS and results obtained for field measurements at different locations of Mangalore and the results of comparative study with the AlphaGuard along with the possible scope for the improvisation are presented and discussed in this paper

  4. Comparison of current tonometry techniques in measurement of intraocular pressure.

    Science.gov (United States)

    Kouchaki, Behrooz; Hashemi, Hassan; Yekta, Abbasali; Khabazkhoob, Mehdi

    2017-06-01

    To compare four tonometry techniques: Goldmann applanation tonometer (GAT), Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response Analyzer (ORA) in the measurement of intraocular pressure (IOP) and the impact of some corneal biomechanical factors on their performance. In this cross-sectional study, volunteers with normal ophthalmic examination and no history of eye surgery (except for uncomplicated cataract surgery) or trauma were selected. Twenty-five subjects were male, and 21 were female. The mean age was 48 ± 19.2 years. Anterior segment parameters were measured with Scheimpflug imaging. IOP was measured with GAT, DCT, NCT, and ORA in random order. A 95% limit of agreement of IOPs was analyzed. The impact of different parameters on the measured IOP with each device was evaluated by regression analysis. The average IOP measured with GAT, DCT, NCT, and ORA was 16.4 ± 3.5, 18.1 ± 3.4, 16.2 ± 3.9, and 17.3 ± 3.4 mmHg, respectively. The difference of IOP measured with NCT and GAT was not significant ( P  = 0.382). Intraocular pressure was significantly different between GAT with DCT and IOP CC ( P  tonometers.

  5. Self-consistent photothermal techniques: Application for measuring thermal diffusivity in vegetable oils

    Science.gov (United States)

    Balderas-López, J. A.; Mandelis, Andreas

    2003-01-01

    The thermal wave resonator cavity (TWRC) was used to measure the thermal properties of vegetable oils. The thermal diffusivity of six commercial vegetable oils (olive, corn, soybean, canola, peanut, and sunflower) was measured by means of this device. A linear relation between both the amplitude and phase as functions of the cavity length for the TWRC was observed and used for the measurements. Three significant figure precisions were obtained. A clear distinction between extra virgin olive oil and other oils in terms of thermal diffusivity was shown. The high measurement precision of the TWRC highlights the potential of this relatively new technique for assessing the quality of this kind of fluids in terms of their thermophysical properties.

  6. Real-time measurements of suspended sediment concentration and particle size using five techniques

    Science.gov (United States)

    Felix, D.; Albayrak, I.; Abgottspon, A.; Boes, R. M.

    2016-11-01

    Fine sediments are important in the design and operation of hydropower plants (HPPs), in particular with respect to sediment management and hydro-abrasive erosion in hydraulic machines. Therefore, there is a need for reliable real-time measurements of suspended sediment mass concentration (SSC) and particle size distribution (PSD). The following instruments for SSC measurements were investigated in a field study during several years at the HPP Fieschertal in the Swiss Alps: (1) turbidimeters, (2) a Laser In-Situ Scattering and Trans- missometry instrument (LISST), (3) a Coriolis Flow and Density Meter (CFDM), (4) acoustic transducers, and (5) pressure sensors. LISST provided PSDs in addition to concentrations. Reference SSCs were obtained by gravimetrical analysis of automatically taken water samples. In contrast to widely used turbidimeters and the single-frequency acoustic method, SSCs obtained from LISST, the CFDM or the pressure sensors were less or not affected by particle size variations. The CFDM and the pressure sensors allowed measuring higher SSC than the optical or the acoustic techniques (without dilution). The CFDM and the pressure sensors were found to be suitable to measure SSC ≥ 2 g/l. In this paper, the measuring techniques, instruments, setup, methods for data treatment, and selected results are presented and discussed.

  7. Study on coal dust wettability measurement using cold briquetting technique

    Energy Technology Data Exchange (ETDEWEB)

    Li, M.; Xu, H.; Shu, X. [North China Institute of Science and Technology, Beijing (China). Department of Resource and Environmental Engineering

    2008-12-15

    Quantitative measuring of coal dust wettability is essential for the research and development of chemical coal dust suppressants in the field of dust control with wetting-agent-added water. The causes of low repeat rate and poor consistency in present lab testing of coal dust wettability are discussed. The influence of different briquetting pressure (from 0 to 6.5108 Pa) on the wet behavior of coal dust is investigated as a new way to quantitatively evaluate coal dust wettability. The study shows that there is a fairly high coincidence between the coal dust wettability data measured by the briquetting technique and the results gained from the lab dust suppression tests using an MCYZ apparatus designed by the authors. 9 refs., 8 figs., 2 tabs.

  8. Vibration measurement-based simple technique for damage detection of truss bridges: A case study

    Directory of Open Access Journals (Sweden)

    Sudath C. Siriwardane

    2015-10-01

    Full Text Available The bridges experience increasing traffic volume and weight, deteriorating of components and large number of stress cycles. Therefore, assessment of the current condition of steel railway bridges becomes necessary. Most of the commonly available approaches for structural health monitoring are based on visual inspection and non-destructive testing methods. The visual inspection is unreliable as those depend on uncertainty behind inspectors and their experience. Also, the non-destructive testing methods are found to be expensive. Therefore, recent researches have noticed that dynamic modal parameters or vibration measurement-based structural health monitoring methods are economical and may also provide more realistic predictions to damage state of civil infrastructure. Therefore this paper proposes a simple technique to locate the damage region of railway truss bridges based on measured modal parameters. The technique is discussed with a case study. Initially paper describes the details of considered railway bridge. Then observations of visual inspection, material testing and in situ load testing are discussed under separate sections. Development of validated finite element model of the considered bridge is comprehensively discussed. Hence, variations of modal parameters versus position of the damage are plotted. These plots are considered as the main reference for locating the damage of the railway bridge in future periodical inspection by comparing the measured corresponding modal parameters. Finally the procedure of periodical vibration measurement and damage locating technique are clearly illustrated.

  9. Material accountancy measurement techniques in dry-powdered processing of nuclear spent fuels

    International Nuclear Information System (INIS)

    Wolf, S. F.

    1999-01-01

    The paper addresses the development of inductively coupled plasma-mass spectrometry (ICPMS), thermal ionization-mass spectrometry (TIMS), alpha-spectrometry, and gamma spectrometry techniques for in-line analysis of highly irradiated (18 to 64 GWD/T) PWR spent fuels in a dry-powdered processing cycle. The dry-powdered technique for direct elemental and isotopic accountancy assay measurements was implemented without the need for separation of the plutonium, uranium and fission product elements in the bulk powdered process. The analyses allow the determination of fuel burn-up based on the isotopic composition of neodymium and/or cesium. An objective of the program is to develop the ICPMS method for direct fissile nuclear materials accountancy in the dry-powdered processing of spent fuel. The ICPMS measurement system may be applied to the KAERI DUPIC (direct use of spent PWR fuel in CANDU reactors) experiment, and in a near-real-time mode for international safeguards verification and non-proliferation policy concerns

  10. CW gain measurements in small-bore argon-ion laser discharges using a novel modulation technique

    International Nuclear Information System (INIS)

    Bennett, W.R. Jr.; Sze, R.C.

    1974-01-01

    A technique for small-signal gain measurements for cw laser systems is described. The method is applied to the measurement of multimode small-signal gain coefficients of small-bone argon-ion laser transitions. (U.S.)

  11. Computed Tomography Fractional Flow Reserve Can Identify Culprit Lesions in Aortoiliac Occlusive Disease Using Minimally Invasive Techniques.

    Science.gov (United States)

    Ward, Erin P; Shiavazzi, Daniele; Sood, Divya; Marsden, Allison; Lane, John; Owens, Erik; Barleben, Andrew

    2017-01-01

    Currently, the gold standard diagnostic examination for significant aortoiliac lesions is angiography. Fractional flow reserve (FFR) has a growing body of literature in coronary artery disease as a minimally invasive diagnostic procedure. Improvements in numerical hemodynamics have allowed for an accurate and minimally invasive approach to estimating FFR, utilizing cross-sectional imaging. We aim to demonstrate a similar approach to aortoiliac occlusive disease (AIOD). A retrospective review evaluated 7 patients with claudication and cross-sectional imaging showing AIOD. FFR was subsequently measured during conventional angiogram with pull-back pressures in a retrograde fashion. To estimate computed tomography (CT) FFR, CT angiography (CTA) image data were analyzed using the SimVascular software suite to create a computational fluid dynamics model of the aortoiliac system. Inlet flow conditions were derived based on cardiac output, while 3-element Windkessel outlet boundary conditions were optimized to match the expected systolic and diastolic pressures, with outlet resistance distributed based on Murray's law. The data were evaluated with a Student's t-test and receiver operating characteristic curve. All patients had evidence of AIOD on CT and FFR was successfully measured during angiography. The modeled data were found to have high sensitivity and specificity between the measured and CT FFR (P = 0.986, area under the curve = 1). The average difference between the measured and calculated FFRs was 0.136, with a range from 0.03 to 0.30. CT FFR successfully identified aortoiliac lesions with significant pressure drops that were identified with angiographically measured FFR. CT FFR has the potential to provide a minimally invasive approach to identify flow-limiting stenosis for AIOD. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Hospitals Productivity Measurement Using Data Envelopment Analysis Technique.

    Science.gov (United States)

    Torabipour, Amin; Najarzadeh, Maryam; Arab, Mohammad; Farzianpour, Freshteh; Ghasemzadeh, Roya

    2014-11-01

    This study aimed to measure the hospital productivity using data envelopment analysis (DEA) technique and Malmquist indices. This is a cross sectional study in which the panel data were used in a 4 year period from 2007 to 2010. The research was implemented in 12 teaching and non-teaching hospitals of Ahvaz County. Data envelopment analysis technique and the Malmquist indices with an input-orientation approach, was used to analyze the data and estimation of productivity. Data were analyzed using the SPSS.18 and DEAP.2 software. Six hospitals (50%) had a value lower than 1, which represents an increase in total productivity and other hospitals were non-productive. the average of total productivity factor (TPF) was 1.024 for all hospitals, which represents a decrease in efficiency by 2.4% from 2007 to 2010. The average technical, technologic, scale and managerial efficiency change was 0.989, 1.008, 1.028, and 0.996 respectively. There was not a significant difference in mean productivity changes among teaching and non-teaching hospitals (P>0.05) (except in 2009 years). Productivity rate of hospitals had an increasing trend generally. However, the total average of productivity was decreased in hospitals. Besides, between the several components of total productivity, variation of technological efficiency had the highest impact on reduce of total average of productivity.

  13. Measuring the diameter of rising gas bubbles by means of the ultrasound transit time technique

    Energy Technology Data Exchange (ETDEWEB)

    Richter, T., E-mail: Thomas.Richter6@tu-dresden.de; Eckert, K., E-mail: Kerstin.Eckert@tu-dresden.de; Yang, X.; Odenbach, S.

    2015-09-15

    Highlights: • Ultrasound transit time technique (UTTT) is applied to the zig-zag raise of gas bubble. • Comparison of bubble diameter and tilt, measured by UTTT, with high-speed imaging. • Uncertainty in the determination of the bubble diameter by UTTT is less than 7%. • UTTT is able to measure dynamic changes in bubble size in opaque liquids and vessels. • UTTT can be applied to liquid metal loops. - Abstract: This study presents ultrasound transit time technique (UTTT) measurements of the diameter variations of single argon bubbles rising in a zig-zag trajectory in water. Simultaneous size measurements with a high-speed camera show that UTTT resolves both the apparent diameter and the tilt of the bubble axis with an accuracy of better than 7%. This qualifies UTTT for the measurement of bubble sizes in opaque liquids, such as liquid metals, or vessels.

  14. Technique of Critical Current Density Measurement of Bulk Superconductor with Linear Extrapolation Method

    International Nuclear Information System (INIS)

    Adi, Wisnu Ari; Sukirman, Engkir; Winatapura, Didin S.

    2000-01-01

    Technique of critical current density measurement (Jc) of HTc bulk ceramic superconductor has been performed by using linear extrapolation with four-point probes method. The measurement of critical current density HTc bulk ceramic superconductor usually causes damage in contact resistance. In order to decrease this damage factor, we introduce extrapolation method. The extrapolating data show that the critical current density Jc for YBCO (123) and BSCCO (2212) at 77 K are 10,85(6) Amp.cm - 2 and 14,46(6) Amp.cm - 2, respectively. This technique is easier, simpler, and the use of the current flow is low, so it will not damage the contact resistance of the sample. We expect that the method can give a better solution for bulk superconductor application. Key words. : superconductor, critical temperature, and critical current density

  15. Spatiotemporal evolution of a laser-induced shock wave measured by the background-oriented schlieren technique

    Science.gov (United States)

    Tagawa, Yoshiyuki; Yamamoto, Shota; Kameda, Masaharu

    2014-11-01

    We investigate the spatiotemporal evolution of a laser-induced shock wave in a liquid filled thin tube. In order to measure pressure distribution at shock front, we adopt the background-oriented schlieren (BOS) technique. This technique provides two- or three-dimensional pressure field in a small region with a simple setup. With an ultra high-speed video camera and a laser stroboscope, we successfully capture the spatial evolution of the shock every 0.2 μs. We find an angular variation of the pressure at the shock front. The maximum pressure is in the direction of the laser shot while the minimum value is in the perpendicular direction. We compare the temporal evolution of the pressure measured by BOS technique with those obtained by another method, i.e. pressure estimation from the shock front position. Overall trend from both methods show a good agreement. The pressure from the shock front position exists between the maximum and minimum values from BOS technique. It indicates that our quantification method can measure more detailed pressure field in two- or three-dimensions. Our results might be used for the efficient generation systems for the microjet, which can be applicable for needle free injection devices.

  16. The stream flow rate measurement using tracer techniques at the Kemubu Agricultural Development Authority (KADA), Kelantan

    International Nuclear Information System (INIS)

    Daud Mohammad; Abd Razak Hamzah; Wan Abd Aziz Wan Mohamad; Juhari Yusoff; Wan Zakaria Wan Mohd Tahir

    1985-01-01

    Measuring the flow rate of a water course is one of the basic operations in hydrology, being of general relevance to water problems and of particular importance in the planning of water control schemes. The techniques commonly used in streamflow gauging are either by a current meter of tracer dilution method. This paper describes the latter technique in which radioisotope Tc-99m was used as a tracer in streamflow measurements performed in 1983 in a few selected irrigation canals and pump house under the Kemubu Agriculture Development Authority (KADA), Kelantan. Total count technique and peak-to-peak method were adopted in this study. (author)

  17. A Technique for Measuring Petal Gloss, with Examples from the Namaqualand Flora

    OpenAIRE

    Whitney, Heather M.; Rands, Sean A.; Elton, Nick J.; Ellis, Allan G.

    2012-01-01

    The degree of floral gloss varies between species. However, little is known about this distinctive floral trait, even though it could be a key feature of floral biotic and abiotic interactions. One reason for the absence of knowledge is the lack of a simple, repeatable method of gloss measurement that can be used in the field to study floral gloss. A protocol is described for measuring gloss in petal samples collected in the field, using a glossmeter. Repeatability of the technique is assesse...

  18. Incremental first pass technique to measure left ventricular ejection fraction

    International Nuclear Information System (INIS)

    Kocak, R.; Gulliford, P.; Hoggard, C.; Critchley, M.

    1980-01-01

    An incremental first pass technique was devised to assess the acute effects of any drug on left ventricular ejection fraction (LVEF) with or without a physiological stress. In particular, the effects of the vasodilater isosorbide dinitrate on LVEF before and after exercise were studied in 11 patients who had suffered cardiac failure. This was achieved by recording the passage of sup(99m)Tc pertechnetate through the heart at each stage of the study using a gamma camera computer system. Consistent values for four consecutive first pass values without exercise or drug in normal subjects illustrated the reproducibility of the technique. There was no significant difference between LVEF values obtained at rest and exercise before or after oral isosorbide dinitrate with the exception of one patient with gross mitral regurgitation. The advantages of the incremental first pass technique are that the patient need not be in sinus rhythm, the effects of physiological intervention may be studied and tests may also be repeated at various intervals during long term follow-up of patients. A disadvantage of the method is the limitation in the number of sequential measurements which can be carried out due to the amount of radioactivity injected. (U.K.)

  19. Development of nonintrusive, scatter-independent techniques for measurement of liquid density inside dense sprays

    Science.gov (United States)

    Hartfield, Roy

    1994-01-01

    A nonintrusive optical technique for measuring the liquid density in sprays used to simulate LOX injector flows is under development. This manuscript is a report on work toward that development which is currently in progress. The technique is a scatter-independent, absorption-based approach which depends on the numerical inversion of a collection of absorption profiles. For the case in which visible radiation passes through liquid-gas interfaces so numerous in sprays, substantial reductions and alterations in the signal result from scattering even in the absence of absorption. To avoid these problems, X-Rays will be used as the absorbed radiation. The experimental process is simulated by integrating the absorption spectrum for a known distribution, adding instrument noise to this 'measurement', creating a projection from the 'measurement', filtering the projection, inverting the projection, and comparing the results with the original prescribed distribution.

  20. Measuring technique of super high temperature thermal properties of reactor core materials

    International Nuclear Information System (INIS)

    Ono, Akira; Baba, Tetsuya; Watanabe, Hideo; Matsumoto, Tsuyoshi

    1998-01-01

    In this study, thermal properties of reactor core materials used for water cooled reactors and FBR were tried to develop a technique to measure their melt states at less than 3,000degC in order to contribute more correct evaluation of the reactor core behavior at severe accident. Then, a thermal property measuring method of high temperature melt by using floating method was investigated and its fundamental design was begun to investigate under a base of optimum judgement on the air flow floating throw-down method. And, in order to measure emissivity of melt specimen surface essential for correct temperature measurement using the throw down method, a spectroscopic emissivity measuring unit using an ellipsometer was prepared and induced. On the thermal properties measurement using the holding method, a specimen container to measure thermal diffusiveness of the high temperature melts by using laser flashing method was tried to prepare. (G.K.)

  1. Measurement of g factors of excited states in radioactive beams by the transient field technique: 132Te

    International Nuclear Information System (INIS)

    Benczer-Koller, N.; Kumbartzki, G.; Gurdal, G; Gross, Carl J; Krieger, B; Hatarik, Robert; O'Malley, Patrick; Pain, S. D.; Segen, L.; Baktash, Cyrus; Bingham, C. R.; Danchev, M.; Grzywacz, R.; Mazzocchi, C.

    2008-01-01

    The g factor of the 2 1 + state in 52 132 Te, E(2 1 + ) = 0.9739 MeV, r = 2.6 ps, was measured by the transient field technique applied to a radioactive beam. The development of an experimental approach necessary for work in radioactive beam environments is described. The result g = 0.28(15) agrees with the previous measurement by the recoil-in-vacuum technique, but here the sign of the g factor is measured as well

  2. Measuring outcomes in adult spinal deformity surgery: a systematic review to identify current strengths, weaknesses and gaps in patient-reported outcome measures.

    Science.gov (United States)

    Faraj, Sayf S A; van Hooff, Miranda L; Holewijn, Roderick M; Polly, David W; Haanstra, Tsjitske M; de Kleuver, Marinus

    2017-08-01

    Adult spinal deformity (ASD) causes severe disability, reduces overall quality of life, and results in a substantial societal burden of disease. As healthcare is becoming more value based, and to facilitate global benchmarking, it is critical to identify and standardize patient-reported outcome measures (PROMs). This study aims to identify the current strengths, weaknesses, and gaps in PROMs used for ASD. Studies were included following a systematic search in multiple bibliographic databases between 2000 and 2015. PROMs were extracted and linked to the outcome domains of WHO's International Classification of Functioning and Health (ICF) framework. Subsequently, the clinimetric quality of identified PROMs was evaluated. The literature search identified 144 papers that met the inclusion criteria, and nine frequently used PROMs were identified. These covered 29 ICF outcome domains, which could be grouped into three of the four main ICF chapters: body function (n = 7), activity and participation (n = 19), environmental factors (n = 3), and body structure (n = 0). A low quantity (n = 3) of papers was identified that studied the clinimetric quality of PROMs. The Scoliosis Research Society (SRS)-22 has the highest level of clinimetric quality for ASD. Outcome domains related to mobility and pain were well represented. We identified a gap in current outcome measures regarding neurological and pulmonary function. In addition, no outcome domains were measured in the ICF chapter body structure. These results will serve as a foundation for the process of seeking international consensus on a standard set of outcome domains, accompanied PROMs and contributing factors to be used in future clinical trials and spine registries.

  3. An inkjet vision measurement technique for high-frequency jetting

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kye-Si, E-mail: kskwon@sch.ac.kr; Jang, Min-Hyuck; Park, Ha Yeong [Department of Mechanical Engineering, Soonchunhyang University 22, Soonchunhyang-Ro, Shinchang, Asan Chungnam 336-745 (Korea, Republic of); Ko, Hyun-Seok [Department of Electrical and Robot Engineering, Soonchunhyang University, 22, Soonchunhyang-Ro, Shinchang, Asan Chungnam 336-745 (Korea, Republic of)

    2014-06-15

    Inkjet technology has been used as manufacturing a tool for printed electronics. To increase the productivity, the jetting frequency needs to be increased. When using high-frequency jetting, the printed pattern quality could be non-uniform since the jetting performance characteristics including the jetting speed and droplet volume could vary significantly with increases in jet frequency. Therefore, high-frequency jetting behavior must be evaluated properly for improvement. However, it is difficult to measure high-frequency jetting behavior using previous vision analysis methods, because subsequent droplets are close or even merged. In this paper, we present vision measurement techniques to evaluate the drop formation of high-frequency jetting. The proposed method is based on tracking target droplets such that subsequent droplets can be excluded in the image analysis by focusing on the target droplet. Finally, a frequency sweeping method for jetting speed and droplet volume is presented to understand the overall jetting frequency effects on jetting performance.

  4. An inkjet vision measurement technique for high-frequency jetting

    International Nuclear Information System (INIS)

    Kwon, Kye-Si; Jang, Min-Hyuck; Park, Ha Yeong; Ko, Hyun-Seok

    2014-01-01

    Inkjet technology has been used as manufacturing a tool for printed electronics. To increase the productivity, the jetting frequency needs to be increased. When using high-frequency jetting, the printed pattern quality could be non-uniform since the jetting performance characteristics including the jetting speed and droplet volume could vary significantly with increases in jet frequency. Therefore, high-frequency jetting behavior must be evaluated properly for improvement. However, it is difficult to measure high-frequency jetting behavior using previous vision analysis methods, because subsequent droplets are close or even merged. In this paper, we present vision measurement techniques to evaluate the drop formation of high-frequency jetting. The proposed method is based on tracking target droplets such that subsequent droplets can be excluded in the image analysis by focusing on the target droplet. Finally, a frequency sweeping method for jetting speed and droplet volume is presented to understand the overall jetting frequency effects on jetting performance

  5. A phase-imaging ion-cyclotron-resonance technique for mass measurements of short-lived nuclides

    Energy Technology Data Exchange (ETDEWEB)

    Eliseev, Sergey; Blaum, Klaus; Doerr, Andreas; Eronen, Tommi; Goncharov, Mikhail; Hoecker, Martin; Ketter, Jochen; Ramirez, Enrique Minaya; Simon, Vanessa [Max-Planck Institute for Nuclear Physics (Germany); Block, Michael [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH (Germany); Chenmarev, Stanislav; Filjanin, Pavel; Nesterenko, Dmitriy; Novikov, Yuri [Petersburg Nuclear Physics Institute (Russian Federation); Droese, Christian; Schweikhard, Lutz [Institute for Physics, Ernst-Moritz-Arndt-University (Germany)

    2014-07-01

    A novel approach to mass measurements on the sub-ppb level even for short-lived nuclides with half-lives well below one second is presented. It is based on the projection of the radial ion motion in a Penning trap onto a position sensitive detector. Compared to the presently employed time-of-flight ion-cyclotron-resonance technique, the novel approach is 25-times faster and provides a 40-fold gain in resolving power. With the new technique low-lying isomeric states with excitation energy on the 10-keV level can be separated from the ground state. Moreover, the new technique possesses a substantially higher sensitivity since just two ions are sufficient to determine the ion cyclotron frequency. A measurement of the mass difference of singly charged ions of {sup 132}Xe and {sup 131}Xe with an uncertainty of 25 eV has demonstrated the great potential of the new approach.

  6. In-situ measurement of mechanical properties of structural components using cyclic ball indentation technique

    International Nuclear Information System (INIS)

    Chatterjee, S.; Madhusoodanan, K.; Panwar, Sanjay; Rupani, B.B.

    2007-01-01

    Material properties of components change during service due to environmental conditions. Measurement of mechanical properties of the components is important for assessing their fitness for service. In many instances, it is not possible to remove sizable samples from the component for doing the measurement in laboratory. In-situ technique for measurement of mechanical properties has great significance in such cases. One of the nondestructive methods that can be adopted for in-situ application is based on cyclic ball indentation technique. It involves multiple indentation cycles (at the same penetration location) on a metallic surface by a spherical indenter. Each cycle consists of indentation, partial unload and reload sequences. Presently, commercial systems are available for doing indentation test on structural component for limited applications. But, there is a genuine need of remotely operable compact in-situ property measurement system. Considering the importance of such applications Reactor Engineering Division of BARC has developed an In-situ Property Measurement System (IProMS), which can be used for in-situ measurement of mechanical properties of a flat or tubular component. This paper highlights the basic theory of measurement, qualification tests on IProMS and results from tests done on flat specimens and tubular component. (author)

  7. Study of a new technique for measuring the travel time of ultrasonic waves using the frequency spectrum

    International Nuclear Information System (INIS)

    Santos, Allan Xavier dos

    2010-01-01

    During the operation of a nuclear plant and other industrial plants, the operational time and the exposition to severe working conditions may cause the wear of its components, consequently, compromising the safety and the performance of the installation. The implementation of periodical inspections helps to ensure the safe operation and the best performance of the plant. In this way, the use of ultrasonic techniques for inspection and materials characterization becomes more and more attractive, since they offer quick, precise results and are technically ease to implement. The usual ultrasonic techniques, need to the measure the travelling time of the ultrasonic wave in the material examined in order to extract information useful to characterize it. Thus, the measurement of the travelling time of the ultrasonic wave is the overriding factor in most of the applications made with ultrasound. In this work a new technique was developed for measuring the travelling time of the ultrasonic wave using a Fourier's Fast Transformer (FFT). It will be shown mathematically and experimentally that it is possible to use the ultrasonic signal in the frequency domain to determine the travelling time of the ultrasonic wave. Five experiments were carried out for the experimental validation of this new technique. The materials used were 20 ceramic pastilles with different porosities and 3 aluminum plates of different thicknesses. The obtained results have shown that the new technique proposed in this work was able to determine the travelling time of the ultrasonic wave with the same precision as the conventional technique. It was shown, furthermore, that this new technique is able to measure the travelling time of the ultrasonic wave in situations where the conventional technique cannot be applied greatly expanding the range of application of ultrasonic testing and inspections. (author)

  8. An angiographic technique for coronary fractional flow reserve measurement: in vivo validation.

    Science.gov (United States)

    Takarada, Shigeho; Zhang, Zhang; Molloi, Sabee

    2013-03-01

    Fractional flow reserve (FFR) is an important prognostic determinant in a clinical setting. However, its measurement currently requires the use of invasive pressure wire, while an angiographic technique based on first-pass distribution analysis and scaling laws can be used to measure FFR using only image data. Eight anesthetized swine were instrumented with flow probe on the proximal segment of the left anterior descending (LAD) coronary arteries. Volumetric blood flow from the flow probe (Qp), coronary pressure (Pa) and right atrium pressure (Pv) were continuously recorded. Flow probe-based FFR (FFRq) was measured from the ratio of flow with and without stenosis. To determine the angiography-based FFR (FFRa), the ratio of blood flow in the presence of a stenosis (QS) to theoretically normal blood flow (QN) was calculated. A region of interest in the LAD arterial bed was drawn to generate time-density curves using angiographic images. QS was measured using a time-density curve and the assumption that blood was momentarily replaced with contrast agent during the injection. QN was estimated from the total coronary arterial volume using scaling laws. Pressure-wire measurements of FFR (FFRp), which was calculated from the ratio of distal coronary pressure (Pd) divided by proximal pressure (Pa), were continuously obtained during the study. A total of 54 measurements of FFRa, FFRp, and FFRq were taken. FFRa showed a good correlation with FFRq (FFRa = 0.97 FFRq +0.06, r(2) = 0.80, p < 0.001), although FFRp overestimated the FFRq (FFRp = 0.657 FFRq + 0.313, r(2) = 0.710, p < 0.0001). Additionally, the Bland-Altman analysis showed a close agreement between FFRa and FFRq. This angiographic technique to measure FFR can potentially be used to evaluate both anatomical and physiological assessments of a coronary stenosis during routine diagnostic cardiac catheterization that requires no pressure wires.

  9. Objective Assessment of Sunburn and Minimal Erythema Doses: Comparison of Noninvasive In Vivo Measuring Techniques after UVB Irradiation

    Science.gov (United States)

    Huang, Min-Wei; Lo, Pei-Yu; Cheng, Kuo-Sheng

    2010-12-01

    Military personnel movement is exposed to solar radiation and sunburn is a major problem which can cause lost workdays and lead to disciplinary action. This study was designed to identify correlation parameters in evaluating in vivo doses and epidermis changes following sunburn inflammation. Several noninvasive bioengineering techniques have made objective evaluations possible. The volar forearms of healthy volunteers ([InlineEquation not available: see fulltext.]), 2 areas, 20 mm in diameter, were irradiated with UVB 100 mj/[InlineEquation not available: see fulltext.] and 200 mj/[InlineEquation not available: see fulltext.], respectively. The skin changes were recorded by several monitored techniques before and 24 hours after UV exposures. Our results showed that chromameter [InlineEquation not available: see fulltext.] value provides more reliable information and can be adopted with mathematical model in predicting the minimal erythema dose (MED) which showed lower than visual assessment by 10 mj/[InlineEquation not available: see fulltext.] (Pearson correlation coefficient [InlineEquation not available: see fulltext.]). A more objective measure for evaluation of MED was established for photosensitive subjects' prediction and sunburn risks prevention.

  10. Measurement of Thermal Properties of Triticale Starch Films Using Photothermal Techniques

    Science.gov (United States)

    Correa-Pacheco, Z. N.; Cruz-Orea, A.; Jiménez-Pérez, J. L.; Solorzano-Ojeda, S. C.; Tramón-Pregnan, C. L.

    2015-06-01

    Nowadays, several commercially biodegradable materials have been developed with mechanical properties similar to those of conventional petrochemical-based polymers. These materials are made from renewable sources such as starch, cellulose, corn, and molasses, being very attractive for numerous applications in the plastics, food, and paper industries, among others. Starches from maize, rice, wheat, and potato are used in the food industry. However, other types of starches are not used due to their low protein content, such as triticale. In this study, starch films, processed using a single screw extruder with different compositions, were thermally and structurally characterized. The thermal diffusivity, thermal effusivity, and thermal conductivity of the biodegradable films were determined using photothermal techniques. The thermal diffusivity was measured using the open photoacoustic cell technique, and the thermal effusivity was obtained by the photopyroelectric technique in an inverse configuration. The results showed differences in thermal properties for the films. Also, the films microstructures were observed by scanning electron microscopy, transmission electron microscopy, and the crystalline structure determined by X-ray diffraction.

  11. Evaluation of bubbler/diaphragm techniques to measure surface level in the waste storage tanks

    International Nuclear Information System (INIS)

    Peters, T.J.; Hickman, B.J.; Colson, J.B.

    1993-10-01

    This report describes the results of tests conducted at the Pacific Northwest Laboratory (PNL) to determine if a bubbler technique can be used to determine the surface level in the waste tanks. Two techniques were evaluated. The first technique is a standard bubbler system in which a tube is placed below the surface of the liquid to be measured and air pressure inside a tube is increased until bubbles begin to become emitted from the tube. The air pressure then is a function of the pressure at the bottom of the tube. The second technique involves a system similar to the standard bubbler technique, but instead of bubbles being released into the material to be gauged, air pressure is increased against a diaphragm until enough pressure is applied to overcome the pressure of the liquid at the given depth, at which time the air then flows in a return loop back to a vent. The advantage of the diaphragm system is that it is a sealed system; thus no air is released into the waste tank materials, and it is not possible for the waste tank materials to get into the air flow. Based on the results of the tests conducted in this program, it appears that the bubbler and diaphragm systems that were tested could not be used for accurate measurements of the level in the waste tanks. Both exhibited deposits of simulated waste tank material at the end of the devices which affected the ability of the gauge to accurately determine changes in the surface level even though the measured value of the level was inaccurate. Further investigations into the cause of this inaccuracy may be warranted. Alternate diaphragm materials may improve the performance of this gauge

  12. A new technique for precise measurement of thermal conductivity of metals at normal and high temperatures

    International Nuclear Information System (INIS)

    Binkele, L.

    1990-09-01

    Theoretical and experimental investigations on a new measuring technique are described; a technique similar to the well known Kohlrausch measuring technique, which is characterized by direct electrical sample heating. Subject of the investigations is a cylindrical metallic sample, 5 mm thick and 200 mm in length, which is positioned vertically between water-cooled clamps in a vacuum container. The sample can be heated using two simultaneously operating current sources, a 50 Hz-source for axial flow (main heating) as well as a 200 kHz-induction source for generating eddy currents in two short regions above and below the sample centre (additional heating). By using two heating sources different symmetrical temperature profiles in a central eddy-current-free area of about ± 10mm can be produced for any given central sample temperature. The last chapter contains thermal conductivity and electrical resistivity measuring curves for Pt, W, Fe, Ni, Ag, Al, Mg, Ir, Ru, Re, Ho and Y in the temperature range 273 to 1500 K representative of all the metals and alloys investigated. In cases where comparisons with published precise conductivity data, established by other measuring techniques in restricted temperature ranges, were posible, the new measuring method is greatly supported (in the case of Pt, W, Ni, Ag, Al). For the Metals Ir, Ru, Re, Ho and Y high temperature thermal conductivity data are given for the first time. (orig./MM) [de

  13. Measurement of elasticity of normal placenta using the Virtual Touch quantification technique

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Size; Nan, Ruixia; Cui, Xiao Jing; Liang, Xian; Zhao, Yanan [Dept. of Ultrasound, Affiliated Hospital of Hainan Medical College, Haikou (China); Li, Yueping [Dept. of Obstetrics and Gynecology, Affiliated Hospital of Hainan Medical College, Haikou (China)

    2016-07-15

    The aim of this study was to measure the elasticity of normal placentas using the Virtual Touch quantification (VTQ) technique. This study was approved by the Institutional Ethics Committee. Fifty randomly selected, healthy pregnant women in their second trimester and 50 randomly selected, healthy pregnant women in their third trimester with a single fetus were included, and their placentas underwent VTQ through shear wave velocity (SWV) measurements. The measurements were performed at different locations to sample different areas of the placenta. Measurements were performed 3-4 times in each location, the mean shear wave velocities were calculated without the highest and lowest values of measurements in each region, and the results were compared. The SWV of the placenta was 0.983±0.260 m/sec, and the minimal and maximal speed was 0.63 m/sec and 1.84 m/sec, respectively. There was no significant difference between the second and third trimester of VTQ of the placenta in terms of SWV (0.978±0.255 m/sec vs. 0.987±0.266 m/sec, P=0.711). The maternal age between second and third trimester was 27.9±4.3 years and 29.2±4.4 years, respectively; there was no significant difference between them (P=0.159). The results of this study show that the SWV of normal placenta tissue is 0.983±0.260 m/sec, it has little variation between the second and third trimesters, and the VTQ technique may potentially play an additional role in placenta evaluation.

  14. Measurement of elasticity of normal placenta using the Virtual Touch quantification technique

    International Nuclear Information System (INIS)

    Wu, Size; Nan, Ruixia; Cui, Xiao Jing; Liang, Xian; Zhao, Yanan; Li, Yueping

    2016-01-01

    The aim of this study was to measure the elasticity of normal placentas using the Virtual Touch quantification (VTQ) technique. This study was approved by the Institutional Ethics Committee. Fifty randomly selected, healthy pregnant women in their second trimester and 50 randomly selected, healthy pregnant women in their third trimester with a single fetus were included, and their placentas underwent VTQ through shear wave velocity (SWV) measurements. The measurements were performed at different locations to sample different areas of the placenta. Measurements were performed 3-4 times in each location, the mean shear wave velocities were calculated without the highest and lowest values of measurements in each region, and the results were compared. The SWV of the placenta was 0.983±0.260 m/sec, and the minimal and maximal speed was 0.63 m/sec and 1.84 m/sec, respectively. There was no significant difference between the second and third trimester of VTQ of the placenta in terms of SWV (0.978±0.255 m/sec vs. 0.987±0.266 m/sec, P=0.711). The maternal age between second and third trimester was 27.9±4.3 years and 29.2±4.4 years, respectively; there was no significant difference between them (P=0.159). The results of this study show that the SWV of normal placenta tissue is 0.983±0.260 m/sec, it has little variation between the second and third trimesters, and the VTQ technique may potentially play an additional role in placenta evaluation

  15. Pre-Analytical Parameters Affecting Vascular Endothelial Growth Factor Measurement in Plasma: Identifying Confounders.

    Science.gov (United States)

    Walz, Johanna M; Boehringer, Daniel; Deissler, Heidrun L; Faerber, Lothar; Goepfert, Jens C; Heiduschka, Peter; Kleeberger, Susannah M; Klettner, Alexa; Krohne, Tim U; Schneiderhan-Marra, Nicole; Ziemssen, Focke; Stahl, Andreas

    2016-01-01

    Vascular endothelial growth factor-A (VEGF-A) is intensively investigated in various medical fields. However, comparing VEGF-A measurements is difficult because sample acquisition and pre-analytic procedures differ between studies. We therefore investigated which variables act as confounders of VEGF-A measurements. Following a standardized protocol, blood was taken at three clinical sites from six healthy participants (one male and one female participant at each center) twice one week apart. The following pre-analytical parameters were varied in order to analyze their impact on VEGF-A measurements: analyzing center, anticoagulant (EDTA vs. PECT / CTAD), cannula (butterfly vs. neonatal), type of centrifuge (swing-out vs. fixed-angle), time before and after centrifugation, filling level (completely filled vs. half-filled tubes) and analyzing method (ELISA vs. multiplex bead array). Additionally, intrapersonal variations over time and sex differences were explored. Statistical analysis was performed using a linear regression model. The following parameters were identified as statistically significant independent confounders of VEGF-A measurements: analyzing center, anticoagulant, centrifuge, analyzing method and sex of the proband. The following parameters were no significant confounders in our data set: intrapersonal variation over one week, cannula, time before and after centrifugation and filling level of collection tubes. VEGF-A measurement results can be affected significantly by the identified pre-analytical parameters. We recommend the use of CTAD anticoagulant, a standardized type of centrifuge and one central laboratory using the same analyzing method for all samples.

  16. Pre-Analytical Parameters Affecting Vascular Endothelial Growth Factor Measurement in Plasma: Identifying Confounders.

    Directory of Open Access Journals (Sweden)

    Johanna M Walz

    Full Text Available Vascular endothelial growth factor-A (VEGF-A is intensively investigated in various medical fields. However, comparing VEGF-A measurements is difficult because sample acquisition and pre-analytic procedures differ between studies. We therefore investigated which variables act as confounders of VEGF-A measurements.Following a standardized protocol, blood was taken at three clinical sites from six healthy participants (one male and one female participant at each center twice one week apart. The following pre-analytical parameters were varied in order to analyze their impact on VEGF-A measurements: analyzing center, anticoagulant (EDTA vs. PECT / CTAD, cannula (butterfly vs. neonatal, type of centrifuge (swing-out vs. fixed-angle, time before and after centrifugation, filling level (completely filled vs. half-filled tubes and analyzing method (ELISA vs. multiplex bead array. Additionally, intrapersonal variations over time and sex differences were explored. Statistical analysis was performed using a linear regression model.The following parameters were identified as statistically significant independent confounders of VEGF-A measurements: analyzing center, anticoagulant, centrifuge, analyzing method and sex of the proband. The following parameters were no significant confounders in our data set: intrapersonal variation over one week, cannula, time before and after centrifugation and filling level of collection tubes.VEGF-A measurement results can be affected significantly by the identified pre-analytical parameters. We recommend the use of CTAD anticoagulant, a standardized type of centrifuge and one central laboratory using the same analyzing method for all samples.

  17. Non-invasive measurement of calcium and phosphorus in human body by NAA technique

    International Nuclear Information System (INIS)

    Wang Haiying; Luo Xianqing; Huang Hanqiao

    1995-01-01

    A system of measuring calcium and phosphorus in human legs has been developed by the use of partial-body neutron activation analysis and partial-body counting technique. The results are compared for the normals and osteoporotic patients

  18. A Comparison of Potential IM-CW Lidar Modulation Techniques for ASCENDS CO2 Column Measurements From Space

    Science.gov (United States)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. Wallace; Obland, Michael D.; Ismail, Syed

    2014-01-01

    Global atmospheric carbon dioxide (CO2) measurements through the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) Decadal Survey recommended space mission are critical for improving our understanding of CO2 sources and sinks. IM-CW (Intensity Modulated Continuous Wave) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS science requirements. In previous laboratory and flight experiments we have successfully used linear swept frequency modulation to discriminate surface lidar returns from intermediate aerosol and cloud contamination. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate clouds, which is a requirement for the inversion of the CO2 column-mixing ratio from the instrument optical depth measurements, has been demonstrated with the linear swept frequency modulation technique. We are concurrently investigating advanced techniques to help improve the auto-correlation properties of the transmitted waveform implemented through physical hardware to make cloud rejection more robust in special restricted scenarios. Several different carrier based modulation techniques are compared including orthogonal linear swept, orthogonal non-linear swept, and Binary Phase Shift Keying (BPSK). Techniques are investigated that reduce or eliminate sidelobes. These techniques have excellent auto-correlation properties while possessing a finite bandwidth (by way of a new cyclic digital filter), which will reduce bias error in the presence of multiple scatterers. Our analyses show that the studied modulation techniques can increase the accuracy of CO2 column measurements from space. A comparison of various properties such as signal to noise ratio (SNR) and time-bandwidth product are discussed.

  19. Application of the Delphi technique in healthcare maintenance.

    Science.gov (United States)

    Njuangang, Stanley; Liyanage, Champika; Akintoye, Akintola

    2017-10-09

    Purpose The purpose of this paper is to examine the research design, issues and considerations in the application of the Delphi technique to identify, refine and rate the critical success factors and performance measures in maintenance-associated infections. Design/methodology/approach In-depth literature review through the application of open and axial coding were applied to formulate the interview and research questions. These were used to conduct an exploratory case study of two healthcare maintenance managers, randomly selected from two National Health Service Foundation Trusts in England. The results of exploratory case study provided the rationale for the application of the Delphi technique in this research. The different processes in the application of the Delphi technique in healthcare research are examined thoroughly. Findings This research demonstrates the need to apply and integrate different research methods to enhance the validity of the Delphi technique. The rationale for the application of the Delphi technique in this research is because some healthcare maintenance managers lack knowledge about basic infection control (IC) principles to make hospitals safe for patient care. The result of first round of the Delphi exercise is a useful contribution in its own rights. It identified a number of salient issues and differences in the opinions of the Delphi participants, noticeably between healthcare maintenance managers and members of the infection control team. It also resulted in useful suggestions and comments to improve the quality and presentation of the second- and third-round Delphi instruments. Practical implications This research provides a research methodology that can be adopted by researchers investigating new and emerging issues in the healthcare sector. As this research demonstrates, the Delphi technique is relevant in soliciting expert knowledge and opinion to identify performance measures to control maintenance-associated infections in

  20. Radioisotope labeling technique for vapor density measurements of volatile inorganic species

    International Nuclear Information System (INIS)

    Peterson, E.J.; Caird, J.A.; Hessler, J.P.; Hoekstra, H.R.; Williams, C.W.

    1979-01-01

    A new method for complexed metal ion vapor density measurement involving labeling the metal ions of interest with a radioactive isotope is described. The isotope chosen in the present work is unstable and leads to emission of a characteristic γ ray. Thus the γ-counting rate was related to the number density of complexed metal ions in the vapor phase. This technique is applicable to the study of any volatile inorganic species, but in the present study has been used to measure vapor densities of complex species in the TbCl 3 -AlCl 3 system by using tracer 160 Tb. 4 figures, 2 tables