WorldWideScience

Sample records for hybridisation assay confirmed

  1. Comparison between fluorescent in-situ hybridisation and array comparative genomic hybridisation in preimplantation genetic diagnosis in translocation carriers.

    Science.gov (United States)

    Lee, Vivian C Y; Chow, Judy F C; Lau, Estella Y L; Yeung, William S B; Ho, P C; Ng, Ernest H Y

    2015-02-01

    To compare the pregnancy outcome of the fluorescent in-situ hybridisation and array comparative genomic hybridisation in preimplantation genetic diagnosis of translocation carriers. Historical cohort. A teaching hospital in Hong Kong. All preimplantation genetic diagnosis treatment cycles performed for translocation carriers from 2001 to 2013. Overall, 101 treatment cycles for preimplantation genetic diagnosis in translocation were included: 77 cycles for reciprocal translocation and 24 cycles for Robertsonian translocation. Fluorescent in-situ hybridisation and array comparative genomic hybridisation were used in 78 and 11 cycles, respectively. The ongoing pregnancy rate per initiated cycle after array comparative genomic hybridisation was significantly higher than that after fluorescent in-situ hybridisation in all translocation carriers (36.4% vs 9.0%; P=0.010). The miscarriage rate was comparable with both techniques. The testing method (array comparative genomic hybridisation or fluorescent in-situ hybridisation) was the only significant factor affecting the ongoing pregnancy rate after controlling for the women's age, type of translocation, and clinical information of the preimplantation genetic diagnosis cycles by logistic regression (odds ratio=1.875; P=0.023; 95% confidence interval, 1.090-3.226). This local retrospective study confirmed that comparative genomic hybridisation is associated with significantly higher pregnancy rates versus fluorescent in-situ hybridisation in translocation carriers. Array comparative genomic hybridisation should be the technique of choice in preimplantation genetic diagnosis cycles in translocation carriers.

  2. Development of a real-time RT-PCR and Reverse Line probe Hybridisation assay for the routine detection and genotyping of Noroviruses in Ireland.

    LENUS (Irish Health Repository)

    Menton, John F

    2007-01-01

    BACKGROUND: Noroviruses are the most common cause of non-bacterial gastroenteritis. Improved detection methods have seen a large increase in the number of human NoV genotypes in the last ten years. The objective of this study was to develop a fast method to detect, quantify and genotype positive NoV samples from Irish hospitals. RESULTS: A real-time RT-PCR assay and a Reverse Line Blot Hybridisation assay were developed based on the ORF1-ORF2 region. The sensitivity and reactivity of the two assays used was validated using a reference stool panel containing 14 NoV genotypes. The assays were then used to investigate two outbreaks of gastroenteritis in two Irish hospitals. 56 samples were screened for NoV using a real-time RT-PCR assay and 26 samples were found to be positive. Genotyping of these positive samples found that all positives belonged to the GII\\/4 variant of NoV. CONCLUSION: The combination of the Real-time assay and the reverse line blot hybridisation assay provided a fast and accurate method to investigate a NoV associated outbreak. It was concluded that the predominant genotype circulating in these Irish hospitals was GII\\/4 which has been associated with the majority of NoV outbreaks worldwide. The assays developed in this study are useful tools for investigating NoV infection.

  3. Genomic confirmation of hybridisation and recent inbreeding in a vector-isolated Leishmania population.

    Science.gov (United States)

    Rogers, Matthew B; Downing, Tim; Smith, Barbara A; Imamura, Hideo; Sanders, Mandy; Svobodova, Milena; Volf, Petr; Berriman, Matthew; Cotton, James A; Smith, Deborah F

    2014-01-01

    Although asexual reproduction via clonal propagation has been proposed as the principal reproductive mechanism across parasitic protozoa of the Leishmania genus, sexual recombination has long been suspected, based on hybrid marker profiles detected in field isolates from different geographical locations. The recent experimental demonstration of a sexual cycle in Leishmania within sand flies has confirmed the occurrence of hybridisation, but knowledge of the parasite life cycle in the wild still remains limited. Here, we use whole genome sequencing to investigate the frequency of sexual reproduction in Leishmania, by sequencing the genomes of 11 Leishmania infantum isolates from sand flies and 1 patient isolate in a focus of cutaneous leishmaniasis in the Çukurova province of southeast Turkey. This is the first genome-wide examination of a vector-isolated population of Leishmania parasites. A genome-wide pattern of patchy heterozygosity and SNP density was observed both within individual strains and across the whole group. Comparisons with other Leishmania donovani complex genome sequences suggest that these isolates are derived from a single cross of two diverse strains with subsequent recombination within the population. This interpretation is supported by a statistical model of the genomic variability for each strain compared to the L. infantum reference genome strain as well as genome-wide scans for recombination within the population. Further analysis of these heterozygous blocks indicates that the two parents were phylogenetically distinct. Patterns of linkage disequilibrium indicate that this population reproduced primarily clonally following the original hybridisation event, but that some recombination also occurred. This observation allowed us to estimate the relative rates of sexual and asexual reproduction within this population, to our knowledge the first quantitative estimate of these events during the Leishmania life cycle.

  4. Localisation and quantification of alkali-labile sites in human spermatozoa by DNA breakage detection-fluorescence in situ hybridisation.

    Science.gov (United States)

    Cortés-Gutiérrez, E I; Dávila-Rodríguez, M I; Cerda-Flores, R M; Fernández, J L; López-Fernández, C; Aragón Tovar, A R; Gosálvez, J

    2015-03-01

    The localisation and quantification of constitutive alkali-labile sites (ALSs) were investigated using a protocol of DNA breakage detection plus fluorescence in situ hybridisation (DBD-FISH) and alkaline single-cell gel electrophoresis (SCGE or comet assay), in spermatozoa of infertile and fertile men. Semen samples from 10 normozoospermic patients undergoing infertility treatment and 10 fertile men were included in this study. ALSs were localised and quantified by DBD-FISH. The region most sensitive to alkali treatment in human spermatozoa was located in the basal region of the head. ALSs were more frequent in spermatozoa of infertile men than in those of fertile men. These results were confirmed by SCGE comet assays. In conclusion, the most intense localisation of hybridisation signals in human spermatozoa, representing the highest density of constitutive ALSs, was not randomly distributed and was predominantly located in the base of the head. Moreover, infertile men presented with an increase in ALS frequency. Further studies are necessary to determine the association between ALS, sperm chromatin organisation and infertility. © 2014 Blackwell Verlag GmbH.

  5. Application of fluorescent in situ hybridisation for demonstration of Coxiella burnetti in placentas from ruminant abortions

    DEFF Research Database (Denmark)

    Jensen, Tim Kåre; Montgomery, Donald L.; Jaeger, Paula T.

    2007-01-01

    A fluorescent in situ hybridisation (FISH) assay targeting 16S ribosomal RNA was developed for detection of the zoonotic bacterium Coxiella burnetii in formalin-fixed, paraffin-embedded tissue, and applied on placentas from ruminant abortions. The applicability of the FISH assay was compared...

  6. Mating, hybridisation and introgression in Lasius ants (Hymenoptera: Formicidae)

    DEFF Research Database (Denmark)

    Van der Have, Tom; Pedersen, Jes Søe; Boomsma, Jacobus Jan

    2011-01-01

    Recent reviews have shown that hybridisation among ant species is likely to be more common than previously appreci-ated, but that documented cases of introgression remain rare. After molecular phylogenetic work had shown that Euro-pean Lasius niger (LINNAEUS, 1758) and L. psammophilus SEIFERT, 1992...... (formerly L. alienus (FOERSTER, 1850)) are unlikely to be very closely related, we decided to analyse an old data set confirming the conclusion by PEARSON (1983) that these two ants can indeed form viable hybrids. We show that signatures of introgression can be detected in a Danish site...... sympatrically. This would imply that multiple accessible field sites are available to study the molecular details of hybridisation and in-trogression between two ant species that have variable degrees of sympatry throughout their distributional ranges...

  7. Climate as possible reproductive barrier in Pinus radiata (D. Don interspecific hybridisation

    Directory of Open Access Journals (Sweden)

    Hannél Ham

    2017-12-01

    Full Text Available Historically, interspecific hybridisation with Pinus radiata D. Don had limited success. The effect of environmental conditions and position of pollination bags in the tree were investigated as possible hybridisation barriers. The study was conducted in a P. radiata seed orchard in the Southern Cape (South Africa. Field data were compared to the climatic conditions at natural and commercial provenances of seven Mesoamerican Pinus species identified as possible hybrid partners. In vitro pollen studies were used to confirm whether interspecific crosses with P. radiata might be feasible within predefined climatic parameters. The temperature ranges for both top and northern side of P. radiata pine trees in the seed orchard was similar to the natural distribution of P. radiata, P. elliottii Engelm. and P. taeda L. in the USA. Results suggested that pollen of P. elliottii and P. taeda might be more suited to result in the successful pollination of P. radiata than the other Mesoamerican pine species tested in this study.  Furthermore, the combination of minimum temperature and precipitation also showed a closer correlation to successful hybridisation with P. radiata for both P. elliotii and P. taeda. However, pollen tube elongation studies did not support these results, suggesting that mean temperature might not be the only determining factor of hybridisation success. Three circadian temperature models that mimic natural conditions were developed for Karatara and Sabie (Tweefontein, Witklip and Spitskop.  These models will be tested in future in vitro studies to further evaluate temperature fluctuations between day and night regimes as a possible reproductive barrier limiting hybridisation success between P. radiata and other Mesoamerican pine species.

  8. High throughput screening of human subtelomeric DNA for copy number changes using multiplex amplifiable probe hybridisation (MAPH).

    Science.gov (United States)

    Hollox, E J; Atia, T; Cross, G; Parkin, T; Armour, J A L

    2002-11-01

    Subtelomeric regions of the human genome are gene rich, with a high level of sequence polymorphism. A number of clinical conditions, including learning disability, have been attributed to subtelomeric deletions or duplications, but screening for deletion in these regions using conventional cytogenetic methods and fluorescence in situ hybridisation (FISH) is laborious. Here we report that a new method, multiplex amplifiable probe hybridisation (MAPH), can be used to screen for copy number at subtelomeric regions. We have constructed a set of MAPH probes with each subtelomeric region represented at least once, so that one gel lane can assay copy number at all chromosome ends in one person. Each probe has been sequenced and, where possible, its position relative to the telomere determined by comparison with mapped clones. The sensitivity of the probes has been characterised on a series of cytogenetically verified positive controls and 83 normal controls were used to assess the frequency of polymorphic copy number with no apparent phenotypic effect. We have also used MAPH to test a cohort of 37 people selected from males referred for fragile X syndrome testing and found six changes that were confirmed by dosage PCR. MAPH can be used to screen subtelomeric regions of chromosomes for deletions and duplications before confirmation by FISH or dosage PCR. The high throughput nature of this technique allows it to be used for large scale screening of subtelomeric copy number, before confirmation by FISH. In practice, the availability of a rapid and efficient screen may allow subtelomeric analysis to be applied to a wider selection of patients than is currently possible using FISH alone.

  9. Radioactive probes for human gene localisation by in situ hybridisation

    International Nuclear Information System (INIS)

    Fennell, S.J.

    1980-07-01

    Radioactive probes of high specific activity have been used for human gene localisation on metaphase chromosome preparations. Human 5S ribosomal RNA was used as a model system, as a probe for the localisation of human 5S ribosomal genes. 125 I-labelled mouse 5S ribosomal RNA was used to study the 5S ribosomal gene content and arrangement in families with translocations on the long arm of chromosome 1 close to or containing the 5S ribosomal RNA locus, by in situ hybridisation to human metaphase chromosomes from peripheral blood cultures. This confirmed the chromosomal assignment of 5S ribosomal genes to 1q 42-43. In situ hybridisation probes were also prepared from recombinant plasmids containing Xenopus laevis oocyte 5S or 28S/18S gene sequences to give [ 3 H]-labelled cRNA and [ 3 H]-labelled nick-translated plasmid DNA. Studies on the kinetics of hybridisation of plasmid probes with and without ribosomal gene sequences questioned the role of plasmid DNA for amplification of signal during gene localisation. Gene localisation was obtained with nick-translated plasmid DNA containing the 28S/18S ribosomal DNA insert after short exposure times, but poor results were obtained using a [ 3 H]-labelled cRNA probe transcribed from the plasmid with the 5S gene insert. (author)

  10. Chromogenic in situ hybridisation (CISH) is a powerful method to detect ALK-positive non-small cell lung carcinomas.

    Science.gov (United States)

    Wagner, F; Streubel, A; Roth, A; Stephan-Falkenau, S; Mairinger, T

    2014-05-01

    We assessed the potential of a chromogenic in situ hybridisation (CISH) assay in comparison with quantitative reverse transcription (RT)-PCR (qPCR) to detect anaplastic lymphoma kinase (ALK) break apart-positive lung carcinomas. Dual-colour CISH using a break apart probe for the ALK gene on 2p23 was performed with 181 formalin-fixed, paraffin-embedded tissue and agar block sections from 175 cases of non-small cell lung carcinomas (NSCLC). Stained slides were analysed with a standard bright-field microscope at 1000× magnification by counting signals from 60 non-overlapping nuclei from three different tumour areas. Samples with ≥15% of positive nuclei were judged as ALK break apart-positive. All samples were simultaneously analysed by qPCR for EML4-ALK to validate CISH results, and positive samples were subject to Sanger sequencing. CISH was successful with 173 of 181 hybridised samples (96%), and seven ALK break apart-positive cases were detected. CISH signals were specific and distinct for both colours. All positive cases were confirmed by qPCR and Sanger sequencing, and concordance between CISH and qPCR was 100%. Nearly all samples (9/10) which failed by qPCR were accessible to CISH analysis. CISH is a very reliable, convenient and inexpensive method to detect ALK-positive NSCLC. CISH success rate is comparably high as with qPCR, and it detects all ALK break apart events in a single assay. It is of special value when RNA quality is poor, or when small biopsies with a very limited amount of tumour cells have to be analysed.

  11. Hybridisation between the Common Buzzard Buteo buteo buteo and ...

    African Journals Online (AJOL)

    Given their close phylogenetic relation and their recently reduced allopatry, an increase in the hybridisation rate, fertile descendants and genetic introgression seem to be viable. We identify the potential contact zones where genetic monitoring is needed to gain insight on the real extent of this hybridisation and its possible ...

  12. In situ hybridisation for identification and differentiation of Mycoplasma hyopneumoniae, Mycoplasma hyosynoviae and Mycoplasma hyorhinis in formalin-fixed porcine tissue sections

    DEFF Research Database (Denmark)

    Boye, Mette; Jensen, Tim Kåre; Ahrens, Peter

    2001-01-01

    Oligonucleotide probes targeting 16S ribosomal RNA were designed for species-specific identification of the porcine mycoplasmas Mycoplasma hyopneumoniae, Mycoplasma hyorhinis and Mycoplasma hyosynoviae using a fluorescent in situ hybridisation assay. The specificity of the probes was evaluated...... using pure cultures as well as porcine tissue sections with artificial presence of mycoplasma, and the probes were found specific for the target organisms. The assay was applied on sections of 28 tissue samples from pigs infected with one or more of the three Mycoplasma species as determined...

  13. Detection of alien genetic introgressions in bread wheat using dot-blot genomic hybridisation.

    Science.gov (United States)

    Rey, María-Dolores; Prieto, Pilar

    2017-01-01

    Simple, reliable methods for the identification of alien genetic introgressions are required in plant breeding programmes. The use of genomic dot-blot hybridisation allows the detection of small Hordeum chilense genomic introgressions in the descendants of genetic crosses between wheat and H. chilense addition or substitution lines in wheat when molecular markers are difficult to use. Based on genomic in situ hybridisation, DNA samples from wheat lines carrying putatively H. chilense introgressions were immobilised on a membrane, blocked with wheat genomic DNA and hybridised with biotin-labelled H. chilense genomic DNA as a probe. This dot-blot screening reduced the number of plants necessary to be analysed by molecular markers or in situ hybridisation, saving time and money. The technique was sensitive enough to detect a minimum of 5 ng of total genomic DNA immobilised on the membrane or about 1/420 dilution of H. chilense genomic DNA in the wheat background. The robustness of the technique was verified by in situ hybridisation. In addition, the detection of other wheat relative species such as Hordeum vulgare , Secale cereale and Agropyron cristatum in the wheat background was also reported .

  14. A description of phases with induced hybridisation at finite temperatures

    Science.gov (United States)

    Golosov, D. I.

    2018-05-01

    In an extended Falicov-Kimball model, an excitonic insulator phase can be stabilised at zero temperature. With increasing temperature, the excitonic order parameter (interaction-induced hybridisation on-site, characterised by the absolute value and phase) eventually becomes disordered, which involves fluctuations of both its phase and (at higher T) its absolute value. In order to build an adequate mean field description, it is important to clarify the nature of degrees of freedom associated with the phase and absolute value of the induced hybridisation, and the corresponding phase space volume. We show that a possible description is provided by the SU(4) parametrisation on-site. In principle, this allows to describe both the lower-temperature regime where phase fluctuations destroy the long-range order, and the higher temperature crossover corresponding to a decrease of absolute value of the hybridisation relative to the fluctuations level. This picture is also expected to be relevant in other contexts, including the Kondo lattice model.

  15. Examination of equine glandular stomach lesions for bacteria, including Helicobacter spp by fluorescence in situ hybridisation

    DEFF Research Database (Denmark)

    husted, Louise; Jensen, Tim Kåre; Olsen, Susanne N.

    2010-01-01

    appearing mucosa were obtained from horses slaughtered for human consumption. All samples were tested for urease activity using the Pyloritek® assay, while mucosal bacterial content was evaluated using Fluorescence In Situ Hybridisation. In selected sub samples, bacteria characterisation was pursued further...... by cloning and sequencing. Mucosal lesions were found in 36/63 stomachs and included hyperplastic rugae, polypoid structures and focal erosions. None of the samples were tested positive for urease activity or for FISH using the Helicobacter genus specific probe. In samples of lesions, as well as normal...

  16. Mating, hybridisation and introgression in Lasius ants

    NARCIS (Netherlands)

    Have, van der T.M.; Pedersen, J.S.; Boomsma, J.J.

    2011-01-01

    Recent reviews have shown that hybridisation among ant species is likely to be more common than previously appreciated. but that documented cases of introgression remain rare. After molecular phylogenetic work had shown that European Lasius niger (LINNAEUS, 1758) and L. psammophilus SEIFERT, 1992

  17. Hybridisation between native Oreochromis species and introduced ...

    African Journals Online (AJOL)

    The Nile tilapia Oreochromis niloticus has been introduced throughout Africa outside its native range for aquaculture purposes. Hybridisation between escaped O. niloticus and native Oreochromis species is of concern due to potential negative effects on wild genetic resources for conservation, aquaculture and capture ...

  18. Hybridisation among groupers (genus Cephalopholis) at the eastern Indian Ocean suture zone: taxonomic and evolutionary implications

    Science.gov (United States)

    Payet, Samuel D.; Hobbs, Jean-Paul A.; DiBattista, Joseph D.; Newman, Stephen J.; Sinclair-Taylor, Tane; Berumen, Michael L.; McIlwain, Jennifer L.

    2016-12-01

    Hybridisation is a significant evolutionary process that until recently was considered rare in the marine environment. A suture zone in the eastern Indian Ocean is home to numerous hybridising sister species, providing an ideal opportunity to determine how hybridisation affects speciation and biodiversity in coral reef fishes. At this location, hybridisation between two grouper (Epinephelidae) species: Cephalopholis urodeta (Pacific Ocean) and C. nigripinnis (Indian Ocean) was investigated to determine the genetic basis of hybridisation and to compare the ecology and life history of hybrids and their parent species. This approach aimed to provide insights into the taxonomic and evolutionary consequences of hybridisation. Despite clear phenotypic differences, multiple molecular markers revealed hybrids, and their parent species were genetically homogenous within and (thousands of kilometres) outside of the hybrid zone. Hybrids were at least as fit as their parent species (in terms of growth, reproduction, and abundance) and were observed in a broad range of intermediate phenotypes. The two species appear to be interbreeding at Christmas Island due to inherent biological and ecological compatibilities, and the lack of genetic structure may be explained by three potential scenarios: (1) hybridisation and introgression; (2) discordance between morphology and genetics; and (3) incomplete lineage sorting. Further molecular analyses are necessary to discriminate these scenarios. Regardless of which applies, C. urodeta and C. nigripinnis are unlikely to evolve in reproductive isolation as they cohabit where they are common (Christmas Island) and will source congeneric mates where they are rare (Cocos Keeling Islands). Our results add to the growing body of evidence that hybridisation among coral reef fishes is a dynamic evolutionary factor.

  19. Hybridisation among groupers (genus Cephalopholis) at the eastern Indian Ocean suture zone: taxonomic and evolutionary implications

    KAUST Repository

    Payet, Samuel D.

    2016-08-05

    Hybridisation is a significant evolutionary process that until recently was considered rare in the marine environment. A suture zone in the eastern Indian Ocean is home to numerous hybridising sister species, providing an ideal opportunity to determine how hybridisation affects speciation and biodiversity in coral reef fishes. At this location, hybridisation between two grouper (Epinephelidae) species: Cephalopholis urodeta (Pacific Ocean) and C. nigripinnis (Indian Ocean) was investigated to determine the genetic basis of hybridisation and to compare the ecology and life history of hybrids and their parent species. This approach aimed to provide insights into the taxonomic and evolutionary consequences of hybridisation. Despite clear phenotypic differences, multiple molecular markers revealed hybrids, and their parent species were genetically homogenous within and (thousands of kilometres) outside of the hybrid zone. Hybrids were at least as fit as their parent species (in terms of growth, reproduction, and abundance) and were observed in a broad range of intermediate phenotypes. The two species appear to be interbreeding at Christmas Island due to inherent biological and ecological compatibilities, and the lack of genetic structure may be explained by three potential scenarios: (1) hybridisation and introgression; (2) discordance between morphology and genetics; and (3) incomplete lineage sorting. Further molecular analyses are necessary to discriminate these scenarios. Regardless of which applies, C. urodeta and C. nigripinnis are unlikely to evolve in reproductive isolation as they cohabit where they are common (Christmas Island) and will source congeneric mates where they are rare (Cocos Keeling Islands). Our results add to the growing body of evidence that hybridisation among coral reef fishes is a dynamic evolutionary factor. © 2016 Springer-Verlag Berlin Heidelberg

  20. Hybridisation among groupers (genus Cephalopholis) at the eastern Indian Ocean suture zone: taxonomic and evolutionary implications

    KAUST Repository

    Payet, Samuel D.; Hobbs, Jean-Paul A.; DiBattista, Joseph; Newman, Stephen J.; Sinclair-Taylor, Tane; Berumen, Michael L.; McIlwain, Jennifer L.

    2016-01-01

    Hybridisation is a significant evolutionary process that until recently was considered rare in the marine environment. A suture zone in the eastern Indian Ocean is home to numerous hybridising sister species, providing an ideal opportunity to determine how hybridisation affects speciation and biodiversity in coral reef fishes. At this location, hybridisation between two grouper (Epinephelidae) species: Cephalopholis urodeta (Pacific Ocean) and C. nigripinnis (Indian Ocean) was investigated to determine the genetic basis of hybridisation and to compare the ecology and life history of hybrids and their parent species. This approach aimed to provide insights into the taxonomic and evolutionary consequences of hybridisation. Despite clear phenotypic differences, multiple molecular markers revealed hybrids, and their parent species were genetically homogenous within and (thousands of kilometres) outside of the hybrid zone. Hybrids were at least as fit as their parent species (in terms of growth, reproduction, and abundance) and were observed in a broad range of intermediate phenotypes. The two species appear to be interbreeding at Christmas Island due to inherent biological and ecological compatibilities, and the lack of genetic structure may be explained by three potential scenarios: (1) hybridisation and introgression; (2) discordance between morphology and genetics; and (3) incomplete lineage sorting. Further molecular analyses are necessary to discriminate these scenarios. Regardless of which applies, C. urodeta and C. nigripinnis are unlikely to evolve in reproductive isolation as they cohabit where they are common (Christmas Island) and will source congeneric mates where they are rare (Cocos Keeling Islands). Our results add to the growing body of evidence that hybridisation among coral reef fishes is a dynamic evolutionary factor. © 2016 Springer-Verlag Berlin Heidelberg

  1. Review of the Application of Modern Cytogenetic Methods (FISH/GISH to the Study of Reticulation (Polyploidy/Hybridisation

    Directory of Open Access Journals (Sweden)

    Michael Chester

    2010-07-01

    Full Text Available The convergence of distinct lineages upon interspecific hybridisation, including when accompanied by increases in ploidy (allopolyploidy, is a driving force in the origin of many plant species. In plant breeding too, both interspecific hybridisation and allopolyploidy are important because they facilitate introgression of alien DNA into breeding lines enabling the introduction of novel characters. Here we review how fluorescence in situ hybridisation (FISH and genomic in situ hybridisation (GISH have been applied to: 1 studies of interspecific hybridisation and polyploidy in nature, 2 analyses of phylogenetic relationships between species, 3 genetic mapping and 4 analysis of plant breeding materials. We also review how FISH is poised to take advantage of nextgeneration sequencing (NGS technologies, helping the rapid characterisation of the repetitive fractions of a genome in natural populations and agricultural plants.

  2. Technological, mediatic and cultural hybridisation: Cultural mediations in the context of globalisation

    Directory of Open Access Journals (Sweden)

    Laan Mendes de Barros

    2009-12-01

    Full Text Available We live in a context of borders that are dissolving in many senses, of the convergence and hybridisation of technologies, mass media and cultures. The context is the resizing of practical time, of movements and links between the local and the global. In these times of interculturality, communication plays a very important role; not so much in its technological media dimension, but particularly in the dynamics of cultural mediations that are dividing off from mediatised relations. This article aims to reflect on the transformations in present-day communication processes, marked by strong movements of hybridisation, as well as examining how to consider interculturality in the context of cultural mediations, based on dialogue between Latin American and French authors. Also, using media material, the article presents illustrations of the Brazilian cultural scene, which is marked by a long history of hybridisation that is filled with intercultural dynamics.

  3. Comparison of Chromogenic In Situ Hybridisation with Fluorescence In Situ Hybridisation and Immunohistochemistry for the Assessment of Her-2/neu Oncogene in Archival Material of Breast Carcinoma

    International Nuclear Information System (INIS)

    Pothos, Alexios; Plastira, Konstantina; Plastiras, Aris; Vlachodimitropoulos, Dimitrios; Goutas, Nikolaos; Angelopoulou, Roxani

    2008-01-01

    The successful treatment of breast cancer is dependent upon a number of complex factors. Her-2/neu gene amplification is known to be one of the most common genetic alterations associated with breast cancer and its accurate determination has become necessary for the selection of patients for trastuzumab therapy. The aim of this study was to prove the consistency of chromogenic in situ hybridisation (CISH) technique after analyzing the overexpression of the Her-2/neu proto-oncogene in 100 invasive breast carcinomas and by comparing CISH results with immunohistochemistry (IHC) and fluorescence in situ hybridisation (FISH). Moreover, it was done to evaluate the possible correlation of estrogen (ERs) and progesterone receptors (PRs), the proliferation marker Ki67 and the tumour suppressor gene p53 with HER-2/neu status of these breast carcinomas. Of the 100 breast carcinomas that were analysed, 22 cases showed HER-2/neu amplification, 66 cases showed no amplification, whereas 12 cases were non-interpretable in both assays (FISH and CISH). Consequently, the overall concordance between FISH and CISH was 100%. Additionally, it was observed that when HER-2/neu gene was overexpressed, there was an association with negative PRs and ERs status, negative p53 protein expression and high Ki67 labelling index. It is concluded that patients with tumours scoring 2+ with the CBE356 antibody (borderline immunohistochemistry-tested cases) would also benefit from CISH as it is shown to be highly accurate, practical and can be easily integrated into routine testing in any histopathology laboratory. Finally, CISH represents an important addition to the HER2 testing algorithm

  4. Interspecific Hybridisation in Campanula

    DEFF Research Database (Denmark)

    Röper, Anna Catharina

    In the present thesis, economically important Campanula species were selected for interspecific hybridisation to increase the genetic viability in plant breeding material. To reach this goal, ovule culture was established as an embryo rescue technique to overcome post-fertilisation barriers...... had an influence on the number of ovules and germination success in some cross combinations. In the second research part interspecific hybrids obtained from ovule culture were genotypically and phenotypically characterised by AFLP analysis, flow cytometry and biometrical parameters. Hybridity...

  5. Design of a multiplex PCR assay for the simultaneous detection and confirmation of Neisseria gonorrhoeae.

    LENUS (Irish Health Repository)

    O'Callaghan, Isabelle

    2010-05-01

    To improve the detection of Neisseria gonorrhoeae by designing a multiplex PCR assay using two N gonorrhoeae-specific genes as targets, thereby providing detection and confirmation of a positive result simultaneously.

  6. Measurement of locus copy number by hybridisation with amplifiable probes

    Science.gov (United States)

    Armour, John A. L.; Sismani, Carolina; Patsalis, Philippos C.; Cross, Gareth

    2000-01-01

    Despite its fundamental importance in genome analysis, it is only recently that systematic approaches have been developed to assess copy number at specific genetic loci, or to examine genomic DNA for submicroscopic deletions of unknown location. In this report we show that short probes can be recovered and amplified quantitatively following hybridisation to genomic DNA. This simple observation forms the basis of a new approach to determining locus copy number in complex genomes. The power and specificity of multiplex amplifiable probe hybridisation is demonstrated by the simultaneous assessment of copy number at a set of 40 human loci, including detection of deletions causing Duchenne muscular dystrophy and Prader–Willi/Angelman syndromes. Assembly of other probe sets will allow novel, technically simple approaches to a wide variety of genetic analyses, including the potential for extension to high resolution genome-wide screens for deletions and amplifications. PMID:10606661

  7. Measurement of locus copy number by hybridisation with amplifiable probes.

    Science.gov (United States)

    Armour, J A; Sismani, C; Patsalis, P C; Cross, G

    2000-01-15

    Despite its fundamental importance in genome analysis, it is only recently that systematic approaches have been developed to assess copy number at specific genetic loci, or to examine genomic DNA for submicro-scopic deletions of unknown location. In this report we show that short probes can be recovered and amplified quantitatively following hybridisation to genomic DNA. This simple observation forms the basis of a new approach to determining locus copy number in complex genomes. The power and specificity of multiplex amplifiable probe hybridisation is demonstrated by the simultaneous assessment of copy number at a set of 40 human loci, including detection of deletions causing Duchenne muscular dystrophy and Prader-Willi/Angelman syndromes. Assembly of other probe sets will allow novel, technically simple approaches to a wide variety of genetic analyses, including the potential for extension to high resolution genome-wide screens for deletions and amplifications.

  8. Morphological and genetic evidence of contemporary intersectional hybridisation in Mediterranean Helichrysum (Asteraceae, Gnaphalieae).

    Science.gov (United States)

    Galbany-Casals, M; Carnicero-Campmany, P; Blanco-Moreno, J M; Smissen, R D

    2012-09-01

    Hybridisation is considered an important evolutionary phenomenon in Gnaphalieae, but contemporary hybridisation has been little explored within the tribe. Here, hybridisation between Helichrysum orientale and Helichrysum stoechas is studied at two different localities in the islands of Crete and Rhodes (Greece). Using three different types of molecular data (AFLP, nrDNA ITS sequences and cpDNA ndhF sequences) and morphological data, the aim is to provide simultaneous and direct comparisons between molecular and morphological variation among the parental species and the studied hybrid populations. AFLP profiles, ITS sequences and morphological data support the existence of hybrids at the two localities studied, shown as morphological and genetic intermediates between the parental species. Chloroplast DNA sequences show that both parental species can act either as pollen donor or as maternal parent. Fertility of hybrids is demonstrated by the viability of seeds produced by hybrids from both localities, and the detection of a backcross specimen to H. orientale. Although there is general congruence of morphological and molecular data, the analysis of morphology and ITS sequences can fail to detect backcross hybrids. © 2012 German Botanical Society and The Royal Botanical Society of the Netherlands.

  9. The hybridising of financial and service expertise in English local authority budget control : a practice perspective.

    OpenAIRE

    Ahrens, T.; Ferry, L.; Khalifa, R.

    2018-01-01

    Purpose This paper aims to trace the hybridising of financial and service expertise in English local authority budget control to provide a more comprehensive understanding of the contexts that gave rise to hybridisation than do previous accountability research frameworks. Design/methodology/approach Using practice theory, this paper interprets the findings from a field study of Newcastle City Council and a review of relevant local authority regulation for England, stretching back to...

  10. Tuberculin purified protein derivative (PPD) immunoassay as an in vitro alternative assay for identity and confirmation of potency.

    Science.gov (United States)

    Ho, Mei M; Kairo, Satnam K; Corbel, Michael J

    2006-01-01

    Tuberculin purified protein derivative (PPD) currently can only be standardised by delayed hypersensitivity skin reactions in sensitised guinea pigs. An in vitro dot blot immunoassay was developed for both identity and confirmation of potency estimation of PPD. Polyclonal antibodies (mainly IgG) were generated and immunoreacted with human, bovine and, to lesser extent, avian PPD preparations. Combining size exclusion chromatography (FPLC-SEC) and dot blot immunoassay, the results showed that PPD preparations were mixtures of very heterogeneous tuberculoproteins ranging in size from very large aggregates to very small degraded molecules. All individual fractions of PPD separated by size were immunoreactive, although those of the largest molecular sizes appeared the most immunoreactive in this in vitro dot blot immunoassay. This method is very sensitive and specific to tuberculoproteins and can be an in vitro alternative for the in vivo intradermal skin assay which uses guinea pigs for identity of PPD preparations. Although the capacity of PPD to elicit cell-mediated immune responses on intradermal testing has to be confirmed by in vivo assay, the dot blot immunoassay offers a rapid, sensitive and animal-free alternative to in vivo testing for confirming the identity of PPD preparations with appropriate potencies. This alternative assay would be particularly useful for national regulatory laboratories for confirming the data of manufacturers and thus reducing the use of animals.

  11. Two-site immunoradiometric assay for the MB isoenzyme of creatine kinase

    Energy Technology Data Exchange (ETDEWEB)

    Willson, V J.C.; Jones, H M; Thompson, R J [Cambridge Univ. (UK). Clinical School

    1981-06-18

    A two-site immunoradiometric assay for myocardial creatine kinase MB isoenzyme is described. The method utilizes immobilized anti-human creatine kinase BB antibodies and /sup 125/I-labelled anti-human creatine kinase MM antibodies and can specifically detect creatine kinase MB in the presence of approximately 1000-fold excess of creatine kinase MM or BB. Native kinase MB prepared from human heart and creatine kinase MB prepared by hybridisation of purified human creatine kinase MM and creatine kinase BB appeared to react identically in the assay. Serum estimations on patients with suspected myocardial infarction correlated with the presence of MB band on electrophoresis but preliminary results suggest that the two-site immunoradiometric assay may be more sensitive.

  12. Human parvovirus B19 infection and hydrops fetalis in Rio de Janeiro, Brazil

    Directory of Open Access Journals (Sweden)

    Rita CN Cubel

    1996-04-01

    Full Text Available Formalin-fixed paraffin embedded lung and liver tissue from 23 cases of non immune hydrops fetalis and five control cases, in which hydrops were due to syphilis (3 and genetic causes (2, were examined for the presence of human parvovirus B19 by DNA hybridisation. Using in situ hybridisation with a biotynilated probe one positive case was detected. Using 32P-labelled probes in a dot blot assay format, five further positives were obtained. These were all confirmed as positive by a nested polymerase chain reaction assay. Electron microscopy revealed virus in all these five positive cases. The six B19 DNA positive cases of hydrops fetalis were from 1974, 1980, 1982, 1987 and 1988, four of which occurred during the second half of the year, confirming the seasonality of the disease.

  13. On hybridising lettuce seedlings with nanoparticles and the resultant effects on the organisms' electrical characteristics.

    Science.gov (United States)

    Gizzie, Nina; Mayne, Richard; Patton, David; Kendrick, Paul; Adamatzky, Andrew

    2016-09-01

    Lettuce seedlings are attracting interest in the computing world due to their capacity to become hybrid circuit components, more specifically, in the creation of living 'wires'. Previous studies have shown that seedlings can be hybridised with gold nanoparticles and withstand mild electrical currents. In this study, lettuce seedlings were hybridised with a variety of metallic and non-metallic nanomaterials: carbon nanotubes, graphene oxide, aluminium oxide and calcium phosphate. Toxic effects and the following electrical properties were monitored: mean potential, resistance and capacitance. Macroscopic observations revealed only slight deleterious health effects after administration with one variety of particle, aluminium oxide. Mean potential in calcium phosphate-hybridised seedlings showed a considerable increase when compared with the control, whereas those administered with graphene oxide showed a small decrease; there were no notable variations across the remaining treatments. Electrical resistance decreased substantially in graphene oxide-treated seedlings whereas slight increases were shown following calcium phosphate and carbon nanotubes applications. Capacitance showed no considerable variation across treated seedlings. These results demonstrate that use of some nanomaterials, specifically graphene oxide and calcium phosphate, may be towards biohybridisation purposes including the generation of living 'wires'. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Fluorescence in situ hybridisation in chromosome aberration detection in subjects occupationally exposed to ionising radiation

    International Nuclear Information System (INIS)

    Zeljezic, D.; Garaj-Vrhovac, V.

    2005-01-01

    For more than two decades, chromosomal aberration analysis has been used to detect structural chromosomal aberrations as sensitive biodosimeters of occupational exposure to ionising radiation. Its use is also recommended by the World Health Organisation. Changes in chromosome structure detected by that method are considered to be early biomarkers of a possible malignant disease. Aberrations detected by the method are unstable and can be found in the lymphocytes of irradiated personnel only within a limited time after exposure. To detect stable chromosomal aberrations, which persist after exposure, multicolour fluorescent in situ hybridisation has to be used. Using DNA probes labelled with different fluorochromes, it dyes each pair of chromosomes with different colour. Due to the dynamic of unstable aberration formation, chromosomal aberration analysis is more suitable in genome damage assessment of recent exposures. On the other hand, fluorescence in situ hybridisation gives the information on chromosome instability caused by long-term occupational exposure to ionising radiation. Considering the high costs of fluorescence in situ hybridisation and the uncertainty of the result, it should be used in biodosimetry only when it is absolutely necessary.(author)

  15. Magnon-Phonon-Hybridisation in FeCl2

    DEFF Research Database (Denmark)

    Ziebeck, K. R. A.; Houmann, Jens Christian Gylden

    1976-01-01

    without an applied magnetic field established the splitting at the nominal point of intersection Kx=0.17 to be 0.32 meV. The application of a 8.9 KG field parallel to the c axis raised the degeneracy of the magnons enabling both polarisations to be identified. From the observed magnon energy gap at Kx=0...... the gyromagnetic ratio g was estimated to be 4.01±0.2 in close agreement with the value 4.14 obtained by resonance experiments. Detailed measurements made in the |100| direction showed that the hybridisation takes place only between the magnons and the low energy TA⊥ (Σ2) phonon in agreement with theory....

  16. Positive Emotional Responses to Hybridised Writing about a Socio-Scientific Issue

    Science.gov (United States)

    Tomas, Louisa; Ritchie, Stephen M.

    2012-01-01

    In order to understand better the role of affect in learning about socio-scientific issues (SSI), this study investigated Year 12 students' emotional arousal as they participated in an online writing-to-learn science project about the socio-scientific issue of biosecurity. Students wrote a series of hybridised scientific narratives, or BioStories,…

  17. Application of conventional chromosomal aberration and fluorescence in-situ hybridisation translocation in the assessment of occupationally derived irradiation

    International Nuclear Information System (INIS)

    Samavat, H.; Seaward, M. R. D.; Gonzales, D. H.; Azizian, Gh.

    2004-01-01

    Background: Most of our current understanding of the biological effects of exposure to ionising radiation is based on conventional cytogenetic techniques, which enable our to determine the relationship between chromosomal aberration and dose received by radiation workers. However, conventional techniques have numerous limitations and chromosomal aberrations can be easily missed. Since fluorescence in situ hybridisation plays an important role in detecting chromosomal changes, this method was used to reassess data derived from previous studies employing conventional techniques. Materials and Methods: Two groups of radiographers were the subject of a study on conventional chromosomal aberration and fluorescence in situ hybridisation for translocation. The first group was chosen following an accidental contamination incident in a nuclear medicine department. The second group was composed of six radiographers working in an x-ray department with a previous record of overdose as recorded by film-badges; these workers had been the subjects of a previous chromosomal study. Coded blood samples from 11 radiographers and 11 controls were analysed for chromosomal aberration and by fluorescence in-situ hybridisation for translocation. 200 metaphases from the peripheral blood lymphocytes per subject were analysed to investigate possible frequencies of chromosome and chromatid type aberration and 2000 metaphases per subject were scored in fluorescence in-situ hybridisation method. Results: There was no significant difference between the radiographers and the control groups in conventional analysis; also there was no significant difference at the 95 % level of confidence in fluorescence in-situ hybridisation analysis. There was no correlation between levels of translocation and total lifetime doses from occupational ( according film-badge and TLD) and/or background irradiation. Conclusion: The overall conclusion is that the frequency of chromosomal damage in both groups of

  18. Chromogenic in situ hybridisation for the assessment of HER2 status in breast cancer: an international validation ring study

    OpenAIRE

    van de Vijver, Marc; Bilous, Michael; Hanna, Wedad; Hofmann, Manfred; Kristel, Petra; Penault-Llorca, Frédérique; Rüschoff, Josef

    2007-01-01

    Introduction Before any new methodology can be introduced into the routine diagnostic setting it must be technically validated against the established standards. To this end, a ring study involving five international pathology laboratories was initiated to validate chromogenic in situ hybridisation (CISH) against fluorescence in situ hybridisation (FISH) and immunohistochemistry (IHC) as a test for assessing human epidermal growth factor receptor 2 (HER2) status in breast cancer. Methods Each...

  19. A two-site immunoradiometric assay for the MB isoenzyme of creatine kinase

    International Nuclear Information System (INIS)

    Willson, V.J.C.; Jones, H.M.; Thompson, R.J.

    1981-01-01

    A two-site immunoradiometric assay for myocardial creatine kinase MB isoenzyme is described. The method utilizes immobilized anti-human creatine kinase BB antibodies and 125 I-labelled anti-human creatine kinase MM antibodies and can specifically detect creatine kinase MB in the presence of approximately 1000-fold excess of creatine kinase MM or BB. Native kinase MB prepared from human heart and creatine kinase MB prepared by hybridisation of purified human creatine kinase MM and creatine kinase BB appeared to react identically in the assay. Serum estimations on patients with suspected myocardial infarction correlated with the presence of MB band on electrophoresis but preliminary results suggest that the two-site immunoradiometric assay may be more sensitive. (Auth.)

  20. Agreement between chromogenic in situ hybridisation (CISH) and FISH in the determination of HER2 status in breast cancer.

    Science.gov (United States)

    Arnould, L; Denoux, Y; MacGrogan, G; Penault-Llorca, F; Fiche, M; Treilleux, I; Mathieu, M C; Vincent-Salomon, A; Vilain, M O; Couturier, J

    2003-05-19

    Determination of the HER2/neu (HER2) status in breast carcinoma has become necessary for the selection of breast cancer patients for trastuzumab therapy. Amplification of the gene analysed by fluorescence in situ hybridisation (FISH) or overexpression of the protein determined by immunohistochemistry (IHC) are the two major methods to establish this status. A strong correlation has been previously demonstrated between these two methods. However, FISH is not always feasible in routine practice and weakly positive IHC tumours (2+) do not always correspond to a gene amplification. Our study was performed in order to evaluate the contribution of chromogenic in situ hybridisation (CISH), which enables detection of the gene copies through an immunoperoxidase reaction. CISH was performed in 79 breast carcinomas for which the HER2 status was previously determined by IHC and FISH. The results of IHC, FISH and CISH were compared for each tumour. CISH procedures were successful in 95% of our cases. Whatever the IHC results, we found a very good concordance (96%) between CISH and FISH. Our study confirms that CISH may be an alternative to FISH for the determination of the gene amplification status in 2+ tumours. Our results allow us to think that, in many laboratories, CISH may also be an excellent method to calibrate the IHC procedures or, as a quality control test, to check regularly that the IHC signal is in agreement with the gene status.

  1. A signal amplification assay for HSV type 1 viral DNA detection using nanoparticles and direct acoustic profiling

    Directory of Open Access Journals (Sweden)

    Hammond Richard

    2010-02-01

    Full Text Available Abstract Background Nucleic acid based recognition of viral sequences can be used together with label-free biosensors to provide rapid, accurate confirmation of viral infection. To enhance detection sensitivity, gold nanoparticles can be employed with mass-sensitive acoustic biosensors (such as a quartz crystal microbalance by either hybridising nanoparticle-oligonucleotide conjugates to complimentary surface-immobilised ssDNA probes on the sensor, or by using biotin-tagged target oligonucleotides bound to avidin-modified nanoparticles on the sensor. We have evaluated and refined these signal amplification assays for the detection from specific DNA sequences of Herpes Simplex Virus (HSV type 1 and defined detection limits with a 16.5 MHz fundamental frequency thickness shear mode acoustic biosensor. Results In the study the performance of semi-homogeneous and homogeneous assay formats (suited to rapid, single step tests were evaluated utilising different diameter gold nanoparticles at varying DNA concentrations. Mathematical models were built to understand the effects of mass transport in the flow cell, the binding kinetics of targets to nanoparticles in solution, the packing geometries of targets on the nanoparticle, the packing of nanoparticles on the sensor surface and the effect of surface shear stiffness on the response of the acoustic sensor. This lead to the selection of optimised 15 nm nanoparticles that could be used with a 6 minute total assay time to achieve a limit of detection sensitivity of 5.2 × 10-12 M. Larger diameter nanoparticles gave poorer limits of detection than smaller particles. The limit of detection was three orders of magnitude lower than that observed using a hybridisation assay without nanoparticle signal amplification. Conclusions An analytical model was developed to determine optimal nanoparticle diameter, concentration and probe density, which allowed efficient and rapid optimisation of assay parameters

  2. Comparison of IgM Capture Enzyme- Linked Immunosorbent Assay (ELISA) using Inhouse method and commercially available MRL kit for serological confirmation of dengue infection

    International Nuclear Information System (INIS)

    Hapugoda, D.M.; De Silva R, Nilanthi; Abeywickreme, W.; Gunasena, Sunethra; Prithimala, L.D.; Jayawardene, S.L.G.J.; Kumari, Thamara

    2003-01-01

    Laboratory diagnosis of dengue infection is important for the management of the patients. In this study igM capture ELISA using an inhouse method and commercially available kit (MRL diagnostics,USA) was compared to detect diagnostic capability of Inhouse IgM ELISA for provision of diagnostic facilities to the public at an affordable cost. Eighty acute and convalescent serum samples were collected from serologically confirmed dengue patients. Serological confirmation of patients were performed by Haemagglutination Inhibition (HI) assay, gold standard assay for dengue on paired serum samples. All collected acute and convalescent sera were tested by IgM ELISA using the inhouse method and MRL kit. Antigen and conjugate for the inhouse IgM method were prepared in the laboratory. A cocktail of four dengue antigens containing 25 Antigen ELISA units of each type was prepared and used as the assay antigen. Conjugate was prepared using a serum sample with high dengue Anti flavi IgG antibody titre conjugated with Horseradish peroxidase. A prospective study of both IgM ELISA assays were performed using 113 acute sera collected from dengue suspected cases. Overall results showed that 46% and 52% acute sera collected from dengue confirmed patients were positive by inhouse ELISA assay and MRL kits respectively. In the prospective study done using acute sera collected from dengue suspected patients showed that 44% and 52% were positive by inhouse ELISA assay and MRL kits. There was no significant difference in positivity between these two assays. (P=0.18). Inhouse IgM ELISA can be used for provision of laboratory diagnosis of dengue virus infection more than 5 days. The assay is 10 times less costly than using MRL kits as assay antigen and conjugate can be prepared easily in the laboratory

  3. Hybridisation or Ousterisation? The Case of Local Accountability Policy in Finnish Early Childhood Education

    Science.gov (United States)

    Paananen, Maiju; Lipponen, Lasse; Kumpulainen, Kristiina

    2015-01-01

    Drawing on the analytic concept of imaginary, this study investigates policy hybridisation in the Finnish early childhood education. Specifically, it illuminates how the interplay between different imaginaries enabled the neoliberal imaginary to oust the social-democratic imaginary through a tripartite process in a case of local productivity…

  4. HER-2 gene amplification by chromogenic in situ hybridisation (CISH) compared with fluorescence in situ hybridisation (FISH) in breast cancer-A study of two hundred cases.

    Science.gov (United States)

    Sáez, A; Andreu, F J; Seguí, M A; Baré, M L; Fernández, S; Dinarés, C; Rey, M

    2006-08-01

    The purpose of the study was to compare two methods used to analyse HER-2 gene amplification (fluorescence in situ hybridisation (FISH) and chromogenic in situ hybridisation (CISH)), and determine the accuracy of the antibodies CB11 and HercepTest for immunohistochemical detection of HER-2 overexpression from archival breast cancer tissue. Additionally, interobserver variability in the interpretation of CISH and immunohistochemical tests was measured. Two hundred cases of invasive breast carcinoma diagnosed between 2000 and 2003 were selected. Immunohistochemistry (IHC) was performed with HercepTest and CB11, and gene amplification was determined by FISH (PathVision, Vysis) and CISH (Zymed) using tissue macroarrays. An excellent concordance (94.8%) was found between CISH and FISH. Considering FISH as gold standard, sensitivity of CISH was 97.5% and specificity 94%. Overall interobserver agreement of CISH was 97.5% and of IHC 84%. Both antibodies showed a sensitivity of 95.2% and a specificity of 70.7% (CB11) and 81.2% (HercepTest). Our results show that CISH is a highly accurate, reproducible and practical technique to determine HER-2 gene amplification. CB11 and HercepTest are good screening methods with a high sensitivity. The performance of tissue macroarrays to test HER-2 status by IHC, FISH and CISH has demonstrated to be an available and effective method to study large series of tumours.

  5. The Hybridisation of Higher Education in Canada

    Directory of Open Access Journals (Sweden)

    Douglas Shale

    2002-01-01

    Full Text Available Canada's postsecondary institutions are becoming increasingly involved with technology enhanced learning, generally under the rubric of distance education. Growth and activity in distance education stems from rapid developments in communication and information technologies such as videoconferencing and the Internet. This case study focuses on the use of new technologies, primarily within the context of higher education institutions operating in Canada's English speaking provinces. Capitalising on the interactive capabilities of "new" learning technologies, some distance education providers are starting to behave more like conventional educational institutions in terms of forming study groups and student cohorts. Conversely, new telecommunications technologies are having a reverse impact on traditional classroom settings, and as a result conventional universities are beginning to establish administrative structures reflective of those used by distance education providers. When viewed in tandem, these trends reflect growing convergence between conventional and distance learning modes, leading to the hybridisation of higher education in Canada.

  6. Analysis of hepatitis B surface antigen (HBsAg) using high-sensitivity HBsAg assays in hepatitis B virus carriers in whom HBsAg seroclearance was confirmed by conventional assays.

    Science.gov (United States)

    Ozeki, Itaru; Nakajima, Tomoaki; Suii, Hirokazu; Tatsumi, Ryoji; Yamaguchi, Masakatsu; Kimura, Mutsuumi; Arakawa, Tomohiro; Kuwata, Yasuaki; Ohmura, Takumi; Hige, Shuhei; Karino, Yoshiyasu; Toyota, Joji

    2018-02-01

    We investigated the utility of high-sensitivity hepatitis B surface antigen (HBsAg) assays compared with conventional HBsAg assays. Using serum samples from 114 hepatitis B virus (HBV) carriers in whom HBsAg seroclearance was confirmed by conventional HBsAg assays (cut-off value, 0.05 IU/mL), the amount of HBsAg was re-examined by high-sensitivity HBsAg assays (cut-off value, 0.005 IU/mL). Cases negative for HBsAg in both assays were defined as consistent cases, and cases positive for HBsAg in the high-sensitivity HBsAg assay only were defined as discrepant cases. There were 55 (48.2%) discrepant cases, and the range of HBsAg titers determined by high-sensitivity HBsAg assays was 0.005-0.056 IU/mL. Multivariate analysis showed that the presence of nucleos(t)ide analog therapy, liver cirrhosis, and negative anti-HBs contributed to the discrepancies between the two assays. Cumulative anti-HBs positivity rates among discrepant cases were 12.7%, 17.2%, 38.8%, and 43.9% at baseline, 1 year, 3 years, and 5 years, respectively, whereas the corresponding rates among consistent cases were 50.8%, 56.0%, 61.7%, and 68.0%, respectively. Hepatitis B virus DNA negativity rates were 56.4% and 81.4% at baseline, 51.3% and 83.3% at 1 year, and 36.8% and 95.7% at 3 years, among discrepant and consistent cases, respectively. Hepatitis B surface antigen reversion was observed only in discrepant cases. Re-examination by high-sensitivity HBsAg assays revealed that HBsAg was positive in approximately 50% of cases. Cumulative anti-HBs seroconversion rates and HBV-DNA seroclearance rates were lower in these cases, suggesting a population at risk for HBsAg reversion. © 2017 The Japan Society of Hepatology.

  7. Karyotype analysis of Lilium longiflorum and Lilium rubellum by chromosome banding and fluorescence in situ hybridisation

    NARCIS (Netherlands)

    Lim, K.B.; Wennekes, J.; Jong, de J.H.S.G.M.; Jacobsen, E.; Tuyl, van J.M.

    2001-01-01

    Detailed karyotypes of Lilium longiflorum and L. rubellum were constructed on the basis of chromosome arm lengths, C-banding, AgNO3 staining, and PI-DAPI banding, together with fluorescence in situ hybridisation (FISH) with the 5S and 45S rDNA sequences as probes. The C-banding patterns that were

  8. Molecular detection and confirmation of Neisseria gonorrhoeae in urogenital and extragenital specimens using the Abbott CT/NG RealTime assay and an in-house assay targeting the porA pseudogene.

    LENUS (Irish Health Repository)

    Walsh, A

    2011-04-01

    Culture for detection of Neisseria gonorrhoeae (NG) is being replaced by molecular assays, but difficulties are observed with false positive and negatives results, especially for extragenital samples. This study evaluates the Abbott CT\\/NG Real-Time assay and a real-time porA pseudogene assay. Samples (n = 600) from a mixed prevalence Irish population include 164 male urines with corresponding urethral swabs, 58 endocervical swabs, 173 male pharyngeal swabs, 205 male rectal swabs, 36 NG clinical isolates and 26 commensal Neisseria species isolates. There was a 100% concordance between the Abbott CT\\/NG Real-Time and the porA assay. The positivity rate was 1.2%, 1.7%, 8.1% and 5.8% for FVU\\/urethral swabs, endocervical, pharyngeal and rectal swabs, respectively. These results were compared to culture and discrepancies were found with nine pharyngeal and three rectal swabs. Seven of the 12 discrepant positive samples were sequenced and were confirmed "true positives". The sensitivity and specificity of the molecular assays was 100%. The sensitivity of the culture-based testing was 100% for urogenital samples but 36% and 75% for pharyngeal and rectal swabs, respectively. The combined Abbott CT\\/NG and porA assays provide a valuable alternative to culture and also generate a significant increase in the diagnosis of pharyngeal and rectal NG infection.

  9. A hybridised variable neighbourhood tabu search heuristic to increase security in a utility network

    International Nuclear Information System (INIS)

    Janssens, Jochen; Talarico, Luca; Sörensen, Kenneth

    2016-01-01

    We propose a decision model aimed at increasing security in a utility network (e.g., electricity, gas, water or communication network). The network is modelled as a graph, the edges of which are unreliable. We assume that all edges (e.g., pipes, cables) have a certain, not necessarily equal, probability of failure, which can be reduced by selecting edge-specific security strategies. We develop a mathematical programming model and a metaheuristic approach that uses a greedy random adaptive search procedure to find an initial solution and uses tabu search hybridised with iterated local search and a variable neighbourhood descend heuristic to improve this solution. The main goal is to reduce the risk of service failure between an origin and a destination node by selecting the right combination of security measures for each network edge given a limited security budget. - Highlights: • A decision model aimed at increasing security in a utility network is proposed. • The goal is to reduce the risk of service failure given a limited security budget. • An exact approach and a variable neighbourhood tabu search heuristic are developed. • A generator for realistic networks is built and used to test the solution methods. • The hybridised heuristic reduces the total risk on average with 32%.

  10. Lab-on-a-chip-based PCR-RFLP assay for the confirmed detection of short-length feline DNA in food.

    Science.gov (United States)

    Ali, Md Eaqub; Al Amin, Md; Hamid, Sharifah Bee Abd; Hossain, M A Motalib; Mustafa, Shuhaimi

    2015-01-01

    Wider availability but lack of legal market trades has given feline meat a high potential for use as an adulterant in common meat and meat products. However, mixing of feline meat or its derivatives in food is a sensitive issue, since it is a taboo in most countries and prohibited in certain religions such as Islam and Judaism. Cat meat also has potential for contamination with of severe acute respiratory syndrome, anthrax and hepatitis, and its consumption might lead to an allergic reaction. We developed a very short-amplicon-length (69 bp) PCR assay, authenticated the amplified PCR products by AluI-restriction digestion followed by its separation and detection on a lab-on-a-chip-based automated electrophoretic system, and proved its superiority over the existing long-amplicon-based assays. Although it has been assumed that longer DNA targets are susceptible to breakdown under compromised states, scientific evidence for this hypothesis has been rarely documented. Strong evidence showed that shorter targets are more stable than the longer ones. We confirmed feline-specificity by cross-challenging the primers against 10 different species of terrestrial, aquatic and plant origins in the presence of a 141-bp site of an 18S rRNA gene as a universal eukaryotic control. RFLP analysis separated 43- and 26-bp fragments of AluI-digest in both the gel-image and electropherograms, confirming the original products. The tested detection limit was 0.01% (w/w) feline meat in binary and ternary admixed as well as meatball matrices. Shorter target, better stability and higher sensitivity mean such an assay would be valid for feline identification even in degraded specimens.

  11. Tomato genome mapping by fluorescence in situ hybridisation = Kartering van het tomatengenoom met behulp van fluorescentie in situ hybridisatie

    NARCIS (Netherlands)

    Zhong, X.B.

    1998-01-01

    The general introduction reviews the progress in tomato genome mapping using classical genetics, cytogenetics, and molecular genetics, emphasising the great potential of fluorescence in situ hybridisation (FISH) techniques.

    Chapter 2 describes how to

  12. Ultrastructural localisation of intramuscular expression of BDNF mRNA by silver-gold intensified non-radioactive in situ hybridisation

    NARCIS (Netherlands)

    Liem, RSB; Brouwer, N; Copray, JCVM

    2001-01-01

    A non-radioactive in situ hybridisation method is described for the detection of low intramuscular levels of brain-derived neurotrophic factor (BDNF) mRNA at the electron microscope level. Application of high-grade silver-gold intensification of the diaminobenzidine end product of in situ

  13. Electronic hybridisation implications for the damage-tolerance of thin film metallic glasses.

    Science.gov (United States)

    Schnabel, Volker; Jaya, B Nagamani; Köhler, Mathias; Music, Denis; Kirchlechner, Christoph; Dehm, Gerhard; Raabe, Dierk; Schneider, Jochen M

    2016-11-07

    A paramount challenge in materials science is to design damage-tolerant glasses. Poisson's ratio is commonly used as a criterion to gauge the brittle-ductile transition in glasses. However, our data, as well as results in the literature, are in conflict with the concept of Poisson's ratio serving as a universal parameter for fracture energy. Here, we identify the electronic structure fingerprint associated with damage tolerance in thin film metallic glasses. Our correlative theoretical and experimental data reveal that the fraction of bonds stemming from hybridised states compared to the overall bonding can be associated with damage tolerance in thin film metallic glasses.

  14. Development and Validation of a Novel LC-MS/MS Opioid Confirmation Assay: Evaluation of β-glucuronidase Enzymes and Sample Cleanup Methods.

    Science.gov (United States)

    Yang, He S; Wu, Alan H B; Lynch, Kara L

    2016-06-01

    With the rise in the use and misuse of prescription opioids, there is an increasing need for the confirmed identification of opioid analgesics in toxicology laboratories. The goals of this study were to (i) systematically evaluate the hydrolysis efficiency of four β-glucuronidase enzymes under optimized condition; (ii) evaluate compound recovery, matrix effects and precision of three protein precipitation plates and (iii) develop and validate a qualitative liquid-chromatography mass spectrometry (LC-MS/MS) assay to identify 13 opioids in urine. A recombinant β-glucuronidase exhibited the best overall hydrolysis efficiency for seven opioid glucuronide conjugates compared with β-glucuronidase from red abalone, Escherichia coli and Patella vulgata One of the protein precipitation plates tested exhibited overall better recovery of the opioids and lower ion suppression compared with the other two plates. An ESI positive mode LC-MS/MS assay for qualitative opioid analysis was developed and validated. Linearity, LOD, precision, matrix effect, recovery, carryover and interference of the method were evaluated. Sixty-two patient samples were analyzed by both a legacy GC-MS opioid method and the LC-MS/MS method, and 22 samples were analyzed by the LC-MS/MS and an LC-MS/MS reference method. The results of the comparisons showed good concordance. Overall, we described an efficient sample preparation procedure for a sensitive qualitative opioid confirmation assay in urine. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Calibration Curves for Biological Dosimetry by Fluorescence In situ Hybridisation

    International Nuclear Information System (INIS)

    Stonati, L.; Durante, M.; Gensabella, G.; Gialanella, G.; Grossi, G.F.; Pugliese, M.; Scampoli, P.; Sgura, A.; Testa, A.; Tanzarella, C.

    2001-01-01

    Dose-response curves were measured for the induction of chromosomal aberrations in peripheral blood lymphocytes after acute exposure in vitro to 60 Co γ rays. Blood was obtained from four different healthy donors, and chromosomes were either observed at metaphase, following colcemid accumulation, or prematurely condensed by calyculin A. Cells were analysed in three different Italian laboratories. Chromosomes 1, 2, and 4 were painted, and simple-type interchanges between painted and non-painted chromosomes were scored in cells exposed in the dose range 0.1-3.0 Gy. The chemical-induced premature chromosome condensation method was also used combined with chromosome painting (chromosome 4 only) to determine calibration curves for high dose exposures (up to 20 Gy X rays). Calibration curves described in this paper will be used in our laboratories for biological dosimetry by fluorescence in situ hybridisation. (author)

  16. Biomonitoring of genotoxic risk in radar facility workers: comparison of the comet assay with micronucleus assay and chromatid breakage assay

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.

    2003-01-01

    Genotoxic risks of occupational exposure in a radar facility were evaluated by using alkaline comet assay, micronucleus assay and chromatid breakage assay on peripheral blood leukocytes in exposed subjects and corresponding controls. Results show that occupational exposure to microwave radiation correlates with an increase of genome damage in somatic cells. The levels of DNA damage in exposed subjects determined by using alkaline comet assay were increased compared to control and showed interindividual variations. Incidence of micronuclei was also significantly increased compared to baseline control values. After short exposure of cultured lymphocytes to bleomycin, cells of occupationally exposed subjects responded with high numbers of chromatid breaks. Although the level of chromosome damage generated by bleomycin varied greatly between individuals, in exposed subjects a significantly elevated number of chromatid breaks was observed. Our results support data reported in literature indicating that microwave radiation represents a potential DNA-damaging hazard. Alkaline comet assay is confirmed as a sensitive and highly reproducible technique for detection of primary DNA damage inflicted in somatic cells. Micronucleus assay was confirmed as reliable bio-markers of effect and chromatid breakage assay as sensitive bio-marker of individual cancer susceptibility. The results obtained also confirm the necessity to improve measures and to perform accurate health surveillance of individuals occupationally exposed to microwave radiation

  17. HER2 testing in the UK: recommendations for breast and gastric in-situ hybridisation methods

    LENUS (Irish Health Repository)

    Bartlett, J. M. S.

    2011-01-01

    These guidelines supplement existing guidelines on HER2 testing by immunohistochemistry and in-situ hybridisation(ISH) methods in the UK. They provide a specific focus on aspects of guidance relevant to HER2 ISH testing methods, both fluorescent and chromogenic. They are formulated to give advice on methodology, interpretation and quality control for ISH-based testing of HER2 status in common tumour types, including both breast and gastric tumours. The aim is to ensure that all ISH-based testing is accurate, reliable and timely.

  18. Niche accumulation and hybridisation strategies in transition processes towards a sustainable energy system: An assessment of differences and pitfalls

    International Nuclear Information System (INIS)

    Raven, Rob

    2007-01-01

    This paper assesses two patterns in transition processes for using them as strategies towards a sustainable energy system, i.e., niche accumulation and hybridisation. Both play important but different roles in transitions. The expected success of these strategies depends on the innovation's history and the innovation context. The different strategies are illustrated with several examples from the energy domain

  19. Assessment of the potential for hybridisation between Laricobius nigrinus (Coleoptera: Derodontidae) and Laricobius osakensis, predators of the hemlock woolly adelgid (Hemiptera: Adelgidae)

    Science.gov (United States)

    Melissa J. Fischer; Carlyle C. Brewster; Nathan P. Havill; Scott M. Salom; Loke T. Kok

    2015-01-01

    In 2003, Laricobius nigrinus Fender was introduced into the eastern United States as a biological control agent of the hemlock woolly adelgid (Adelges tsugae Annand). Following its release, it was discovered that L. nigrinus was hybridising and producing viable progeny with Laricobius rubidus...

  20. Preimplantation genetic diagnosis and screening by array comparative genomic hybridisation: experience of more than 100 cases in a single centre.

    Science.gov (United States)

    Chow, J Fc; Yeung, W Sb; Lee, V Cy; Lau, E Yl; Ho, P C; Ng, E Hy

    2017-04-01

    Preimplantation genetic screening has been proposed to improve the in-vitro fertilisation outcome by screening for aneuploid embryos or blastocysts. This study aimed to report the outcome of 133 cycles of preimplantation genetic diagnosis and screening by array comparative genomic hybridisation. This study of case series was conducted in a tertiary assisted reproductive centre in Hong Kong. Patients who underwent preimplantation genetic diagnosis for chromosomal abnormalities or preimplantation genetic screening between 1 April 2012 and 30 June 2015 were included. They underwent in-vitro fertilisation and intracytoplasmic sperm injection. An embryo biopsy was performed on day-3 embryos and the blastomere was subject to array comparative genomic hybridisation. Embryos with normal copy numbers were replaced. The ongoing pregnancy rate, implantation rate, and miscarriage rate were studied. During the study period, 133 cycles of preimplantation genetic diagnosis for chromosomal abnormalities or preimplantation genetic screening were initiated in 94 patients. Overall, 112 cycles proceeded to embryo biopsy and 65 cycles had embryo transfer. The ongoing pregnancy rate per transfer cycle after preimplantation genetic screening was 50.0% and that after preimplantation genetic diagnosis was 34.9%. The implantation rates after preimplantation genetic screening and diagnosis were 45.7% and 41.1%, respectively and the miscarriage rates were 8.3% and 28.6%, respectively. There were 26 frozen-thawed embryo transfer cycles, in which vitrified and biopsied genetically transferrable embryos were replaced, resulting in an ongoing pregnancy rate of 36.4% in the screening group and 60.0% in the diagnosis group. The clinical outcomes of preimplantation genetic diagnosis and screening using comparative genomic hybridisation in our unit were comparable to those reported internationally. Genetically transferrable embryos replaced in a natural cycle may improve the ongoing pregnancy rate

  1. Splicing analysis for exonic and intronic mismatch repair gene variants associated with Lynch syndrome confirms high concordance between minigene assays and patient RNA analyses

    Science.gov (United States)

    van der Klift, Heleen M; Jansen, Anne M L; van der Steenstraten, Niki; Bik, Elsa C; Tops, Carli M J; Devilee, Peter; Wijnen, Juul T

    2015-01-01

    A subset of DNA variants causes genetic disease through aberrant splicing. Experimental splicing assays, either RT-PCR analyses of patient RNA or functional splicing reporter minigene assays, are required to evaluate the molecular nature of the splice defect. Here, we present minigene assays performed for 17 variants in the consensus splice site regions, 14 exonic variants outside these regions, and two deep intronic variants, all in the DNA mismatch-repair (MMR) genes MLH1, MSH2, MSH6, and PMS2, associated with Lynch syndrome. We also included two deep intronic variants in APC and PKD2. For one variant (MLH1 c.122A>G), our minigene assay and patient RNA analysis could not confirm the previously reported aberrant splicing. The aim of our study was to further investigate the concordance between minigene splicing assays and patient RNA analyses. For 30 variants results from patient RNA analyses were available, either performed by our laboratory or presented in literature. Some variants were deliberately included in this study because they resulted in multiple aberrant transcripts in patient RNA analysis, or caused a splice effect other than the prevalent exon skip. While both methods were completely concordant in the assessment of splice effects, four variants exhibited major differences in aberrant splice patterns. Based on the present and earlier studies, together showing an almost 100% concordance of minigene assays with patient RNA analyses, we discuss the weight given to minigene splicing assays in the current criteria proposed by InSiGHT for clinical classification of MMR variants. PMID:26247049

  2. Fluorescence (FISH) and chromogenic (CISH) in situ hybridisation in prostate carcinoma cell lines: comparison and use of virtual microscopy.

    Science.gov (United States)

    Elliott, K; Hamilton, P W; Maxwell, P

    2008-01-01

    Chromogenic in situ hybridisation (CISH) has become an attractive alternative to fluorescence in situ hybridisation (FISH) due to its permanent stain which is more familiar to pathologists and because it can be viewed using light microscopy. The aim of the present study is to examine reproducibility in the assessment of abnormal chromosome number by CISH in comparison to FISH. Using three prostate cell lines--PNT1A (derived from normal epithelium), LNCAP and DU145 (derived from prostatic carcinoma), chromosomes 7 and 8 were counted in 40 nuclei in FISH preparations (x100 oil immersion) and 100 nuclei in CISH preparations (x40) by two independent observers. The CISH slides were examined using standard light microscopy and virtual microscopy. Reproducibility was examined using paired Student's t-test (PCISH. No significant differences in chromosome count were seen between the techniques. Chromosomes 7 and 8 showed disomic status for each cell line except LNCAP, which proved to be heterogeneous (disomic/aneusomic), particularly for chromosome 8. Virtual microscopy proved to be easy to use and gave no significant differences from standard light microscopy. These results support the hypothesis that there is no significant difference between FISH and CISH techniques.

  3. Genetic Diversity and Hybridisation between Native and Introduced Salmonidae Fishes in a Swedish Alpine Lake.

    Directory of Open Access Journals (Sweden)

    Leanne Faulks

    Full Text Available Understanding the processes underlying diversification can aid in formulating appropriate conservation management plans that help maintain the evolutionary potential of taxa, particularly under human-induced activities and climate change. Here we assessed the microsatellite genetic diversity and structure of three salmonid species, two native (Arctic charr, Salvelinus alpinus and brown trout, Salmo trutta and one introduced (brook charr, Salvelinus fontinalis, from an alpine lake in sub-arctic Sweden, Lake Ånn. The genetic diversity of the three species was similar and sufficiently high from a conservation genetics perspective: corrected total heterozygosity, H'T = 0.54, 0.66, 0.60 and allelic richness, AR = 4.93, 5.53 and 5.26 for Arctic charr, brown trout and brook charr, respectively. There were indications of elevated inbreeding coefficients in brown trout (GIS = 0.144 and brook charr (GIS = 0.129 although sibling relationships were likely a confounding factor, as a high proportion of siblings were observed in all species within and among sampling locations. Overall genetic structure differed between species, Fst = 0.01, 0.02 and 0.04 in Arctic charr, brown trout and brook charr respectively, and there was differentiation at only a few specific locations. There was clear evidence of hybridisation between the native Arctic charr and the introduced brook charr, with 6% of individuals being hybrids, all of which were sampled in tributary streams. The ecological and evolutionary consequences of the observed hybridisation are priorities for further research and the conservation of the evolutionary potential of native salmonid species.

  4. Simultaneous and independent detection of C9ORF72 alleles with low and high number of GGGGCC repeats using an optimised protocol of Southern blot hybridisation.

    Science.gov (United States)

    Buchman, Vladimir L; Cooper-Knock, Johnathan; Connor-Robson, Natalie; Higginbottom, Adrian; Kirby, Janine; Razinskaya, Olga D; Ninkina, Natalia; Shaw, Pamela J

    2013-04-08

    Sizing of GGGGCC hexanucleotide repeat expansions within the C9ORF72 locus, which account for approximately 10% of all amyotrophic lateral sclerosis (ALS) cases, is urgently required to answer fundamental questions about mechanisms of pathogenesis in this important genetic variant. Currently employed PCR protocols are limited to discrimination between the presence and absence of a modified allele with more than 30 copies of the repeat, while Southern hybridisation-based methods are confounded by the somatic heterogeneity commonly present in blood samples, which might cause false-negative or ambiguous results. We describe an optimised Southern hybridisation-based protocol that allows confident detection of the presence of a C9ORF72 repeat expansion alongside independent assessment of its heterogeneity and the number of repeat units. The protocol can be used with either a radiolabeled or non-radiolabeled probe. Using this method we have successfully sized the C9ORF72 repeat expansion in lymphoblastoid cells, peripheral blood, and post-mortem central nervous system (CNS) tissue from ALS patients. It was also possible to confidently demonstrate the presence of repeat expansion, although of different magnitude, in both C9ORF72 alleles of the genome of one patient. The suggested protocol has sufficient advantages to warrant adoption as a standard for Southern blot hybridisation analysis of GGGGCC repeat expansions in the C9ORF72 locus.

  5. Reproductive glycogenetics--a critical factor in pregnancy success and species hybridisation.

    Science.gov (United States)

    Jones, C J P; Aplin, J D

    2009-03-01

    Hybridisation occurs rarely in nature and experiments using interspecific transfer of embryos generally result in implantation failure. Here we show that appropriate glycosylation of the apposing surfaces of endometrium and trophoblast probably is an important factor and may play a critical role in pregnancy success. Examination of closely related species shows that each has its own specific pattern of glycosylation, or glycotype, at the fetomaternal interface and that interacting surfaces appear to show complementarity, suggesting the existence of a glycocode. Studies on a camel/llama hybrid show that for successful implantation to occur, a hybrid must have a placental glycosylation pattern similar to that of the host species, suggesting that the glycocode and appropriate glycosylation may be critical factors in the establishment and maintenance of pregnancy. This new field of reproductive glycogenetics is not only relevant to the development of new species but may also have important implications in the area of human fertility.

  6. The ''Hybrid Effect''. Influence of hybridisation on the durability of automatic transmissions; Der ''Hybrid-Effekt''. Einfluss der Hybridisierung auf die Lebensdauer von Automatikgetrieben

    Energy Technology Data Exchange (ETDEWEB)

    Lavall, Thomas [ZF Getriebe GmbH, Friedrichshafen (Germany)

    2009-07-01

    The series development of hybrid systems in combination with the new ZF 8-speed automatic transmissions contains also for the testing several aspects of challenge the complex overall system with additional loads, components and functions requires new definitions of testing volumes and load collectives with an ideal integration of testing expertise of all parties involved. This paper describes how, already in an early development stage of the fully hybridised 8-speed transmission system, specific load collectives have been developed with the aid of simulation. So the ''hybrid-effect'' as an additional load and its influence on the durability compared to non hybridised applications could be identified. Also it is shown how testing collectives have been adapted in practice to the hybrid specific needs to the point of a specific assembly of a test bench. The ZF testing concept for hybridised automatic transmissions has the ability of an early and efficient verification of the production readiness also securing highest possible series production quality for prospective hybrid projects. (orig.)

  7. A DNA Microarray-Based Assay to Detect Dual Infection with Two Dengue Virus Serotypes

    Directory of Open Access Journals (Sweden)

    Alvaro Díaz-Badillo

    2014-04-01

    Full Text Available Here; we have described and tested a microarray based-method for the screening of dengue virus (DENV serotypes. This DNA microarray assay is specific and sensitive and can detect dual infections with two dengue virus serotypes and single-serotype infections. Other methodologies may underestimate samples containing more than one serotype. This technology can be used to discriminate between the four DENV serotypes. Single-stranded DNA targets were covalently attached to glass slides and hybridised with specific labelled probes. DENV isolates and dengue samples were used to evaluate microarray performance. Our results demonstrate that the probes hybridized specifically to DENV serotypes; with no detection of unspecific signals. This finding provides evidence that specific probes can effectively identify single and double infections in DENV samples.

  8. Identification of lymphogranuloma venereum-associated Chlamydia trachomatis serovars by fluorescence in situ hybridisation--a proof-of-principle analysis.

    Science.gov (United States)

    Frickmann, Hagen; Essig, Andreas; Poppert, Sven

    2014-04-01

    We describe a proof-of-principle evaluation of a fluorescence in situ hybridisation (FISH) procedure to identify Chlamydia trachomatis serovars L1-L3, the causative agents of lymphogranuloma venereum, in cell cultures based on newly designed DNA probes. Rapid and easy-to-perform FISH could facilitate the diagnosis of lymphogranuloma venereum without nucleic acid amplification or serotyping, but requires broader evaluation studies, for example, in tropical high-endemicity regions. © 2014 John Wiley & Sons Ltd.

  9. Characterisation of the nucleolar organising regions during the cell cycle in two varieties of Petunia hybrida as visualised by fluorescence in situ hybridisation and silver staining.

    Science.gov (United States)

    Montijn, M B; ten Hoopen, R; Fransz, P F; Oud, J L; Nanninga, N

    1998-05-01

    The cell cycle-dependent spatial position, morphology and activity of the four nucleolar organising regions (NORs) of the Petunia hybrida cultivar Mitchell and the inbred line V26 have been analysed. Application of the silver staining technique and fluorescence in situ hybridisation on fixed root-tip material revealed that these interspecific hybrids possess four NORs of which only those of chromosome 2 are active during interphase, which implies that the NOR activity is not of parental origin. However, at the end of mitosis, activity of all NOR regions could be detected, suggesting that the high demand for ribosomes at this stage of the cell cycle requires temporal activity of all NORs. Using actin DNA probes as markers in fluorescence in situ hybridisation experiments enabled the identification of the individual petunia chromosomes.

  10. Atypical myopathy in Denmark confirmed with the aTRAQ assay

    DEFF Research Database (Denmark)

    Høffer, Sofie Esbjørn; Votion, Dominique-Marie; Anderberg, Marie

    2016-01-01

    Atypical myopathy is a severe form of rhabdomyolysis that occurs in grazing horses. Over the past decades, the disease has been emerging in Europe. The disease is widespread in Europe and has been suspected in Denmark since 2000, yet no cases have been confirmed. The objective of this study...

  11. Array comparative genomic hybridisation analysis of boys with X linked hypopituitarism identifies a 3.9 Mb duplicated critical region at Xq27 containing SOX3.

    NARCIS (Netherlands)

    Solomon, N.M.; Ross, S.; Morgan, T.; Belsky, J.L.; Hol, F.A.; Karnes, P.; Hopwood, N.J.; Myers, S.E.; Tan, A.; Warne, G.L.; Forrest, S.M.; Thomas, P.Q.

    2004-01-01

    INTRODUCTION: Array comparative genomic hybridisation (array CGH) is a powerful method that detects alteration of gene copy number with greater resolution and efficiency than traditional methods. However, its ability to detect disease causing duplications in constitutional genomic DNA has not been

  12. Coupling of an indicator-free electrochemical DNA biosensor with polymerase chain reaction for the detection of DNA sequences related to the apolipoprotein E

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Fausto; Marrazza, Giovanna; Palchetti, Ilaria; Cesaretti, S.; Mascini, Marco

    2002-09-26

    This paper describes a disposable indicator-free electrochemical DNA biosensor applied to the detection of apolipoprotein E (apoE) sequences in PCR samples. In the indicator-free assays, the duplex formation was detected by measuring the electrochemical signal of the guanine base of nucleic acids. The biosensor format involved the immobilisation of an inosine-modified (guanine-free) probe onto a screen-printed electrode (SPE) transducer and the detection of the duplex formation in connection with the square-wave voltammetric measurement of the oxidation peak of the guanine of the target sequence. The indicator-free scheme has been characterised using 23-mer oligonucleotides as model: parameters affecting the hybridisation assay such as probe immobilisation conditions, hybridisation time, use of hybridisation accelerators were examined and optimised. The analysis of PCR samples (244 bp DNA fragments, obtained by amplification of DNA extracted from human blood) required a further optimisation of the experimental procedure. In particular, a lower steric hyndrance of the probe modified surface was essential to allow an efficient hybridisation of the target DNA fragment. Negative controls have been performed using the PCR blank and amplicons unrelated to the immobilised probe. A 10 min hybridisation time allowed a full characterisation of each sample.

  13. Monitoring of the microbial community composition of the saline aquifers during CO2 storage by fluorescence in situ hybridisation

    OpenAIRE

    Daria Morozova; M. Wandrey; Mashal Alawi; Martin Zimmer; Andrea Vieth-Hillebrand [Vieth; M. Zettlitzer; Hilke Würdemann

    2010-01-01

    This study reveals the first analyses of the composition and activity of the microbial community of a saline CO2 storage aquifer. Microbial monitoring during CO2 injection has been reported. By using fluorescence in situ hybridisation (FISH), we have shown that the microbial community was strongly influenced by the CO2 injection. Before CO2 arrival, up to 6 × 106 cells ml−1 were detected by DAPI staining at a depth of 647 m below the surface. The microbial community was dominated by the dom...

  14. Experimental analysis of Hybridised Energy Storage Systems for automotive applications

    Science.gov (United States)

    Sarwar, Wasim; Engstrom, Timothy; Marinescu, Monica; Green, Nick; Taylor, Nigel; Offer, Gregory J.

    2016-08-01

    The requirements of the Energy Storage System (ESS) for an electrified vehicle portfolio consisting of a range of vehicles from micro Hybrid Electric Vehicle (mHEV) to a Battery Electric Vehicle (BEV) vary considerably. To reduce development cost of an electrified powertrain portfolio, a modular system would ideally be scaled across each vehicle; however, the conflicting requirements of a mHEV and BEV prevent this. This study investigates whether it is possible to combine supercapacitors suitable for an mHEV with high-energy batteries suitable for use in a BEV to create a Hybridised Energy Storage System (HESS) suitable for use in a HEV. A passive HESS is found to be capable of meeting the electrical demands of a HEV drive cycle; the operating principles of HESSs are discussed and factors limiting system performance are explored. The performance of the HESS is found to be significantly less temperature dependent than battery-only systems, however the heat generated suggests a requirement for thermal management. As the HESS degrades (at a similar rate to a specialised high-power-battery), battery resistance rises faster than supercapacitor resistance; as a result, the supercapacitor provides a greater current contribution, therefore the energy throughput, temperature rise and degradation of the batteries is reduced.

  15. Introducing a new breed of wine yeast: interspecific hybridisation between a commercial Saccharomyces cerevisiae wine yeast and Saccharomyces mikatae.

    Science.gov (United States)

    Bellon, Jennifer R; Schmid, Frank; Capone, Dimitra L; Dunn, Barbara L; Chambers, Paul J

    2013-01-01

    Interspecific hybrids are commonplace in agriculture and horticulture; bread wheat and grapefruit are but two examples. The benefits derived from interspecific hybridisation include the potential of generating advantageous transgressive phenotypes. This paper describes the generation of a new breed of wine yeast by interspecific hybridisation between a commercial Saccharomyces cerevisiae wine yeast strain and Saccharomyces mikatae, a species hitherto not associated with industrial fermentation environs. While commercially available wine yeast strains provide consistent and reliable fermentations, wines produced using single inocula are thought to lack the sensory complexity and rounded palate structure obtained from spontaneous fermentations. In contrast, interspecific yeast hybrids have the potential to deliver increased complexity to wine sensory properties and alternative wine styles through the formation of novel, and wider ranging, yeast volatile fermentation metabolite profiles, whilst maintaining the robustness of the wine yeast parent. Screening of newly generated hybrids from a cross between a S. cerevisiae wine yeast and S. mikatae (closely-related but ecologically distant members of the Saccharomyces sensu stricto clade), has identified progeny with robust fermentation properties and winemaking potential. Chemical analysis showed that, relative to the S. cerevisiae wine yeast parent, hybrids produced wines with different concentrations of volatile metabolites that are known to contribute to wine flavour and aroma, including flavour compounds associated with non-Saccharomyces species. The new S. cerevisiae x S. mikatae hybrids have the potential to produce complex wines akin to products of spontaneous fermentation while giving winemakers the safeguard of an inoculated ferment.

  16. Cytokine Release Assays as Tests for Exposure to Leishmania, and for Confirming Cure from Leishmaniasis, in Solid Organ Transplant Recipients.

    Directory of Open Access Journals (Sweden)

    Eugenia Carrillo

    Full Text Available Spain has one of the world's largest pools of organ donors and is a global leader in terms of the number of transplants it performs. The current outbreak of leishmaniasis in Fuenlabrada (in the southwest of the region of Madrid, Spain has involved 600 clinical cases since late 2009 (prevalence 0.2%. It may therefore be wise to monitor the town's transplanted population for Leishmania infantum; its members are immunosuppressed and at greater risk of infection and relapse following treatment. The present work examines the use of cytokine release assays to determine the prevalence of Leishmania infection in this population, and to confirm recovery following treatment for visceral leishmaniasis (VL. The humoral and cellular immune responses to L. infantum were characterized in 63 solid organ transplant (SOT recipients from Fuenlabrada, 57 of whom reported no previous episode of VL (NVL subjects, and six of whom had been cured of VL (CVL subjects. Seventeen subjects (12 NVL and 5 CVL showed a patent lymphoproliferative response to soluble Leishmania antigen (SLA. Stimulation of peripheral blood mononuclear cell cultures and of whole blood with SLA led to the production of different combinations of cytokines that might serve to confirm Leishmania infection or recovery from VL and help prevent cured patients from relapsing into this serious condition.

  17. Introducing a new breed of wine yeast: interspecific hybridisation between a commercial Saccharomyces cerevisiae wine yeast and Saccharomyces mikatae.

    Directory of Open Access Journals (Sweden)

    Jennifer R Bellon

    Full Text Available Interspecific hybrids are commonplace in agriculture and horticulture; bread wheat and grapefruit are but two examples. The benefits derived from interspecific hybridisation include the potential of generating advantageous transgressive phenotypes. This paper describes the generation of a new breed of wine yeast by interspecific hybridisation between a commercial Saccharomyces cerevisiae wine yeast strain and Saccharomyces mikatae, a species hitherto not associated with industrial fermentation environs. While commercially available wine yeast strains provide consistent and reliable fermentations, wines produced using single inocula are thought to lack the sensory complexity and rounded palate structure obtained from spontaneous fermentations. In contrast, interspecific yeast hybrids have the potential to deliver increased complexity to wine sensory properties and alternative wine styles through the formation of novel, and wider ranging, yeast volatile fermentation metabolite profiles, whilst maintaining the robustness of the wine yeast parent. Screening of newly generated hybrids from a cross between a S. cerevisiae wine yeast and S. mikatae (closely-related but ecologically distant members of the Saccharomyces sensu stricto clade, has identified progeny with robust fermentation properties and winemaking potential. Chemical analysis showed that, relative to the S. cerevisiae wine yeast parent, hybrids produced wines with different concentrations of volatile metabolites that are known to contribute to wine flavour and aroma, including flavour compounds associated with non-Saccharomyces species. The new S. cerevisiae x S. mikatae hybrids have the potential to produce complex wines akin to products of spontaneous fermentation while giving winemakers the safeguard of an inoculated ferment.

  18. Introducing a New Breed of Wine Yeast: Interspecific Hybridisation between a Commercial Saccharomyces cerevisiae Wine Yeast and Saccharomyces mikatae

    Science.gov (United States)

    Bellon, Jennifer R.; Schmid, Frank; Capone, Dimitra L.; Dunn, Barbara L.; Chambers, Paul J.

    2013-01-01

    Interspecific hybrids are commonplace in agriculture and horticulture; bread wheat and grapefruit are but two examples. The benefits derived from interspecific hybridisation include the potential of generating advantageous transgressive phenotypes. This paper describes the generation of a new breed of wine yeast by interspecific hybridisation between a commercial Saccharomyces cerevisiae wine yeast strain and Saccharomyces mikatae, a species hitherto not associated with industrial fermentation environs. While commercially available wine yeast strains provide consistent and reliable fermentations, wines produced using single inocula are thought to lack the sensory complexity and rounded palate structure obtained from spontaneous fermentations. In contrast, interspecific yeast hybrids have the potential to deliver increased complexity to wine sensory properties and alternative wine styles through the formation of novel, and wider ranging, yeast volatile fermentation metabolite profiles, whilst maintaining the robustness of the wine yeast parent. Screening of newly generated hybrids from a cross between a S. cerevisiae wine yeast and S. mikatae (closely-related but ecologically distant members of the Saccharomyces sensu stricto clade), has identified progeny with robust fermentation properties and winemaking potential. Chemical analysis showed that, relative to the S. cerevisiae wine yeast parent, hybrids produced wines with different concentrations of volatile metabolites that are known to contribute to wine flavour and aroma, including flavour compounds associated with non-Saccharomyces species. The new S. cerevisiae x S. mikatae hybrids have the potential to produce complex wines akin to products of spontaneous fermentation while giving winemakers the safeguard of an inoculated ferment. PMID:23614011

  19. Comparison of a newly developed automated and quantitative hepatitis C virus (HCV) core antigen test with the HCV RNA assay for clinical usefulness in confirming anti-HCV results.

    Science.gov (United States)

    Kesli, Recep; Polat, Hakki; Terzi, Yuksel; Kurtoglu, Muhammet Guzel; Uyar, Yavuz

    2011-12-01

    Hepatitis C virus (HCV) is a global health care problem. Diagnosis of HCV infection is mainly based on the detection of anti-HCV antibodies as a screening test with serum samples. Recombinant immunoblot assays are used as supplemental tests and for the final detection and quantification of HCV RNA in confirmatory tests. In this study, we aimed to compare the HCV core antigen test with the HCV RNA assay for confirming anti-HCV results to determine whether the HCV core antigen test may be used as an alternative confirmatory test to the HCV RNA test and to assess the diagnostic values of the total HCV core antigen test by determining the diagnostic specificity and sensitivity rates compared with the HCV RNA test. Sera from a total of 212 treatment-naive patients were analyzed for anti-HCV and HCV core antigen both with the Abbott Architect test and with the molecular HCV RNA assay consisting of a reverse transcription-PCR method as a confirmatory test. The diagnostic sensitivity, specificity, and positive and negative predictive values of the HCV core antigen assay compared to the HCV RNA test were 96.3%, 100%, 100%, and 89.7%, respectively. The levels of HCV core antigen showed a good correlation with those from the HCV RNA quantification (r = 0.907). In conclusion, the Architect HCV antigen assay is highly specific, sensitive, reliable, easy to perform, reproducible, cost-effective, and applicable as a screening, supplemental, and preconfirmatory test for anti-HCV assays used in laboratory procedures for the diagnosis of hepatitis C virus infection.

  20. Evaluation of total PSA assay on vitros ECi and correlation with Kryptor-PSA assay.

    Science.gov (United States)

    Cassinat, B; Wacquet, M; Toubert, M E; Rain, J D; Schlageter, M H

    2001-01-01

    An increasing number of multiparametric immuno-analysers for PSA assays are available. As different immuno-assays may vary in their analytical quality and their accuracy for the follow-up of patients, expertise is necessary for each new assay. The PSA assay on the Vitros-ECi analyser has been evaluated and compared with the PSA assay from the Kryptor analyser. Variation coefficients were 0.91 to 1.98% for within-run assays, and 4.2% to 5.4% for interassay (PSA levels = 0.8 microgram/L to 33.6 micrograms/L). Dilution tests showed 93 to 136% recovery until 70 micrograms/L PSA. Functional sensitivity was estimated at 0.03 microgram/L. Equimolarity of the test was confirmed. Correlation of PSA levels measured with Vitros-ECi and Kryptor analysers displayed a correlation coefficient r2 of 0.9716. The half-lives and doubling times of PSA were similar using both methods. Vitros-ECi PSA assay meets the major criteria for the management of prostate cancer patients.

  1. Medium Affect Desire: Hybridising Real Virtual and the Actualised through Affective Medium Ecology

    Directory of Open Access Journals (Sweden)

    Marc Boumeester

    2014-10-01

    Full Text Available Underneath the turbulent surface of the ubiquitous media-scape lies an even more agile and aggressive set of relations. A central figure in this turmoil of desires seems to be the asignifying sign, which has a hybridising liaison with both the realm of the real virtual and the realm of the actualised. The main question is what does it want? This new materialistic, non-anthropocentric liberty of affect is creating an arena of strange attractors and other topological vector fields in which our own unconscious drive is as effective as that of the steel ball in a pinball machine. Could we isolate the intrinsic drive of the medium from its subservient position in the aesthetic, freeing its desire from the anthropocentric dominion? What does it Yen for? Perhaps this gap is not meant to be filled, as it is this yearning what it yearns for. The asignifying sign cannot be isolated, it is neither here nor there, yet it is conditionally omnipresent, it inhibits the gap, its desire is to affect.

  2. Cytogenetic bio-dosimetry of an accidental exposure of a radiological worker using multiple assays

    International Nuclear Information System (INIS)

    Thierens, H.; De Ruyck, K.; Vral, A.; De Gelder, V.; Whitehouse, C. A.; Tawn, E. J.; Boesman, I.

    2005-01-01

    A technician involved in the maintenance of X-ray equipment visited the occupational medicine service with complaints of skin lesions, apparently caused by an accidental exposure three months earlier. To estimate the dose received by the technician in the accident, bio-dosimetry was performed 6 and 18 months post-exposure with the dicentric and micronucleus assays. Part of the latest blood sample was also used for retrospective dosimetry by fluorescence in situ hybridisation (FISH) analysis for translocations. The data obtained 6 and 18 months post-exposure indicate that both dicentrics and micronuclei disappear with a half-time of 1 y. After correction for delayed blood sampling, dose values of 0.75 Gy (95% confidence limits 0.56-1.05 Gy) from dicentrics and 0.96 Gy (95% confidence limits 0.79-1.18 Gy) from micronuclei were obtained. FISH analysis of translocations resulted in a dose estimate of 0.79 Gy (95% confidence limits 0.61-0.99 Gy). The satisfactory agreement between the three cytogenetic endpoints supports the use of the micronucleus assay for triage purposes in the case of large scale radiological accidents and provides further evidence for the valid use of FISH for translocations as a reliable retrospective biological dosimeter. (authors)

  3. Virological confirmation of suspected dengue in a Phase 2 Latin American vaccine trial: Implications for vaccine efficacy evaluation

    Directory of Open Access Journals (Sweden)

    Mark Boaz

    2014-01-01

    Full Text Available The CYD tetravalent dengue vaccine candidate is being evaluated for protective efficacy against symptomatic dengue in Phase 3 efficacy trials. The laboratory test algorithm to confirm dengue cases was evaluated prior to Phase 3 trials. During a Phase 2 trial in Latin America a dengue epidemic occurred in the study countries. A total of 72 suspected dengue cases were reported and assessed: virological confirmation comprised qRT-PCR methods and a commercial ELISA kit for NS1 protein (Bio-Rad. The qRT-PCR included a screening assay targeting a conserved dengue region of the 3′-UTR (dengue screen assay followed by 4 individual serotype assays targeting the conserved dengue NS5 genomic region (WT dengue qRT-PCR assays. The NS1 and WT dengue qRT-PCR were endpoint assays for protocol virological confirmation (PVC. Of the 72 suspected cases, 14 were PVC. However, a unique pattern of dengue qRT-PCR results were observed in 5 suspected cases from Honduras: the dengue screen qRT-PCR assay was positive but WT dengue qRT-PCR and NS1 Ag ELISA were negative. To investigate these observations, additional molecular methods were applied: a SYBR® Green-based RT-PCR assay, sequencing assays directed at the genome regions covered by the WT dengue qRT-PCR, and a modified commercial dengue RT-PCR test (Simplexa™ Dengue, Focus Diagnostics. The exploratory data confirmed these additional cases as dengue and indicated the serotype 2 WT dengue qRT-PCR assay was unable to detect a circulating Latin American strain (DENV-2/NI/BID-V608/2006 due to a sequence variation in the isolate. The Simplexa Dengue RT-PCR test was able to detect and serotype dengue. Based on these findings an updated molecular test algorithm for the virological confirmation of dengue cases was developed and implemented in the Phase 3 efficacy trials.

  4. Application of a Reverse Line Blot hybridisation assay for the species-specific identification of cyathostomins (Nematoda, Strongylida) from benzimidazole-treated horses in the Slovak Republic.

    Science.gov (United States)

    Cernanská, Dana; Paoletti, Barbara; Králová-Hromadová, Ivica; Iorio, Raffaella; Cudeková, Patrícia; Milillo, Piermarino; Traversa, Donato

    2009-03-09

    Five horse farms located in eastern Slovakia were investigated for the presence of benzimidazole-resistant strongyles by faecal egg count reduction test and egg hatch assay. Coprocultures were prepared for each farm from faecal samples taken pre- and post-treatment and harvested larvae were molecularly examined with a Reverse Line Blot assay. Faecal egg count reduction values ranged from 0 to 52.5% and all farms were positive for benzimidazole-resistant cyathostomins. Seven benzimidazole-resistant cyathostomin species were molecularly identified on farms before and also after treatment. These data demonstrate that resistance to benzimidazoles is well established in cyathostomin populations from horse farms in the Slovak Republic and that the molecular assay was able to determine the species-specific distribution of resistant cyathostomins under field conditions.

  5. Real-time PCR based on SYBR-Green I fluorescence: An alternative to the TaqMan assay for a relative quantification of gene rearrangements, gene amplifications and micro gene deletions

    Directory of Open Access Journals (Sweden)

    Puisieux Alain

    2003-10-01

    Full Text Available Abstract Background Real-time PCR is increasingly being adopted for RNA quantification and genetic analysis. At present the most popular real-time PCR assay is based on the hybridisation of a dual-labelled probe to the PCR product, and the development of a signal by loss of fluorescence quenching as PCR degrades the probe. Though this so-called 'TaqMan' approach has proved easy to optimise in practice, the dual-labelled probes are relatively expensive. Results We have designed a new assay based on SYBR-Green I binding that is quick, reliable, easily optimised and compares well with the published assay. Here we demonstrate its general applicability by measuring copy number in three different genetic contexts; the quantification of a gene rearrangement (T-cell receptor excision circles (TREC in peripheral blood mononuclear cells; the detection and quantification of GLI, MYC-C and MYC-N gene amplification in cell lines and cancer biopsies; and detection of deletions in the OPA1 gene in dominant optic atrophy. Conclusion Our assay has important clinical applications, providing accurate diagnostic results in less time, from less biopsy material and at less cost than assays currently employed such as FISH or Southern blotting.

  6. Exogenous DNA internalisation by sperm cells is improved by combining lipofection and restriction enzyme mediated integration.

    Science.gov (United States)

    Churchil, R R; Gupta, J; Singh, A; Sharma, D

    2011-06-01

    1. Three types of exogenous DNA inserts, i.e. complete linearised pVIVO2-GFP/LacZ vector (9620 bp), the LacZ gene (5317 bp) and the GFP gene (2152 bp) were used to transfect chicken spermatozoa through simple incubation of sperm cells with insert. 2. PCR assay, Dot Blot hybridisation and Southern hybridisation showed the successful internalisation of exogenous DNA by chicken sperm cells. 3. Lipofection and Restriction Enzyme Mediated Integration (REMI) were used to improve the rate of internalisation of exogenous DNA by sperm cells. 4. Results from dot blot as well as Southern hybridisation were semi-quantified and improved exogenous DNA uptake by sperm cells through lipofection and REMI. Stronger signals were observed from hybridisation of LacZ as well as GFP specific probe with the DNA from lipofected exogenous DNA transfected sperm DNA in comparison with those transfected with nude exogenous DNA.

  7. Hybridisation of solar and geothermal energy in both subcritical and supercritical Organic Rankine Cycles

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Cheng

    2014-05-01

    Highlights: • Hybrid solar and geothermal energy conversion system was modelled using subcritical and supercritical ORCs. • Solar thermal and geothermal energy can be effectively hybridised. • Greater thermodynamic advantages and economic benefits can be achieved using the supercritical hybrid plant. • Hybrid plants can produce up to 19% more annual electricity than the two stand-alone plants. • Solar-to-electricity cost in the supercritical hybrid plant is about 4–19% less than in the subcritical plant. - Abstract: A supercritical Organic Rankine Cycle (ORC) is renowned for higher conversion efficiency than the conventional ORC due to a better thermal match (i.e. reduced irreversibility) presented in the heat exchanger unit. This improved thermal match is a result of the obscured liquid-to-vapor boundary of the organic working fluid at supercritical states. Stand-alone solar thermal power generation and stand-alone geothermal power generation using a supercritical ORC have been widely investigated. However, the power generation capability of a single supercritical ORC using combined solar and geothermal energy has not been examined. This paper thus investigates the hybridisation of solar and geothermal energy in a supercritical ORC to explore the benefit from the potential synergies of such a hybrid platform. Its performances were also compared with those of a subcritical hybrid plant, stand-alone solar and geothermal plants. All simulations and modelling of the power cycles were carried out using process simulation package Aspen HYSYS. The performances of the hybrid plant were then assessed using technical analysis, economic analysis, and the figure of merit analysis. The results of the technical analysis show that thermodynamically, the hybrid plant using a supercritical ORC outperforms the hybrid plant using a subcritical ORC if at least 66% of its exergy input is met by solar energy (i.e. a solar exergy fraction of >66%), namely producing 4–17

  8. Hybridisation of solar and geothermal energy in both subcritical and supercritical Organic Rankine Cycles

    International Nuclear Information System (INIS)

    Zhou, Cheng

    2014-01-01

    Highlights: • Hybrid solar and geothermal energy conversion system was modelled using subcritical and supercritical ORCs. • Solar thermal and geothermal energy can be effectively hybridised. • Greater thermodynamic advantages and economic benefits can be achieved using the supercritical hybrid plant. • Hybrid plants can produce up to 19% more annual electricity than the two stand-alone plants. • Solar-to-electricity cost in the supercritical hybrid plant is about 4–19% less than in the subcritical plant. - Abstract: A supercritical Organic Rankine Cycle (ORC) is renowned for higher conversion efficiency than the conventional ORC due to a better thermal match (i.e. reduced irreversibility) presented in the heat exchanger unit. This improved thermal match is a result of the obscured liquid-to-vapor boundary of the organic working fluid at supercritical states. Stand-alone solar thermal power generation and stand-alone geothermal power generation using a supercritical ORC have been widely investigated. However, the power generation capability of a single supercritical ORC using combined solar and geothermal energy has not been examined. This paper thus investigates the hybridisation of solar and geothermal energy in a supercritical ORC to explore the benefit from the potential synergies of such a hybrid platform. Its performances were also compared with those of a subcritical hybrid plant, stand-alone solar and geothermal plants. All simulations and modelling of the power cycles were carried out using process simulation package Aspen HYSYS. The performances of the hybrid plant were then assessed using technical analysis, economic analysis, and the figure of merit analysis. The results of the technical analysis show that thermodynamically, the hybrid plant using a supercritical ORC outperforms the hybrid plant using a subcritical ORC if at least 66% of its exergy input is met by solar energy (i.e. a solar exergy fraction of >66%), namely producing 4–17

  9. Discordant human T-lymphotropic virus screening with Western blot confirmation: evaluation of the dual-test algorithm for US blood donations.

    Science.gov (United States)

    Stramer, Susan L; Townsend, Rebecca L; Foster, Gregory A; Johnson, Ramona; Weixlmann, Barbara; Dodd, Roger Y

    2018-03-01

    Human T-lymphotropic virus (HTLV) blood donation screening has used a dual-testing algorithm beginning with either a chemiluminescent immunoassay or enzyme-linked immunosorbent screening assay (ELISA). Before the availability of a licensed HTLV supplemental assay, repeat-reactive (RR) samples on a first assay (Assay 1) were retested with a second screening assay (Assay 2). Donors with RR results by Assay 2 were deferred from blood donation and further tested using an unlicensed supplemental test to confirm reactivity while nonreactive (NR) donors remained eligible for donation until RR on a subsequent donation. This "dual-test" algorithm was replaced in May 2016 with the requirement that all RRs by Assay 1 be further tested by a licensed HTLV supplemental test (Western blot [WB]). In this study, we have requalified the dual-test algorithm using the available licensed HTLV WB. We tested 100 randomly selected HTLV RRs on screening Assay 1 (Abbott PRISM chemiluminescent immunoassay) but NR on screening Assay 2 (Avioq ELISA) by a Food and Drug Administration-licensed WB (MP Biomedicals) to ensure that no confirmed positives were among those that were RR by Assay 1 but NR by Assay 2. Of the 100 samples evaluated, 79 of 100 were WB seronegative, 21 of 100 indeterminate, and 0 of 100 seropositive. Of the 79 of 100 seronegative specimens, 73 of 79 did not express any bands on WB. We demonstrated that none of the 100 samples RR on Assay 1 but NR on Assay 2 were confirmed positive. This algorithm prevents such donors from requiring further testing and from being deferred. © 2018 AABB.

  10. Hybridisations of Variable Neighbourhood Search and Modified Simplex Elements to Harmony Search and Shuffled Frog Leaping Algorithms for Process Optimisations

    Science.gov (United States)

    Aungkulanon, P.; Luangpaiboon, P.

    2010-10-01

    Nowadays, the engineering problem systems are large and complicated. An effective finite sequence of instructions for solving these problems can be categorised into optimisation and meta-heuristic algorithms. Though the best decision variable levels from some sets of available alternatives cannot be done, meta-heuristics is an alternative for experience-based techniques that rapidly help in problem solving, learning and discovery in the hope of obtaining a more efficient or more robust procedure. All meta-heuristics provide auxiliary procedures in terms of their own tooled box functions. It has been shown that the effectiveness of all meta-heuristics depends almost exclusively on these auxiliary functions. In fact, the auxiliary procedure from one can be implemented into other meta-heuristics. Well-known meta-heuristics of harmony search (HSA) and shuffled frog-leaping algorithms (SFLA) are compared with their hybridisations. HSA is used to produce a near optimal solution under a consideration of the perfect state of harmony of the improvisation process of musicians. A meta-heuristic of the SFLA, based on a population, is a cooperative search metaphor inspired by natural memetics. It includes elements of local search and global information exchange. This study presents solution procedures via constrained and unconstrained problems with different natures of single and multi peak surfaces including a curved ridge surface. Both meta-heuristics are modified via variable neighbourhood search method (VNSM) philosophy including a modified simplex method (MSM). The basic idea is the change of neighbourhoods during searching for a better solution. The hybridisations proceed by a descent method to a local minimum exploring then, systematically or at random, increasingly distant neighbourhoods of this local solution. The results show that the variant of HSA with VNSM and MSM seems to be better in terms of the mean and variance of design points and yields.

  11. Quantitative CrAssphage PCR Assays for Human Fecal ...

    Science.gov (United States)

    Environmental waters are monitored for fecal pollution to protect public health and water resources. Traditionally, general fecal indicator bacteria are used; however, they cannot distinguish human fecal waste from pollution from other animals. Recently, a novel bacteriophage, crAssphage, was discovered by metagenomic data mining and reported to be abundant in and closely associated with human fecal waste. To confirm bioinformatic predictions, 384 primer sets were designed along the length of the crAssphage genome. Based upon initial screening, two novel crAssphage qPCR assays (CPQ_056 and CPQ_064) were designed and evaluated in reference fecal samples and water matrices. The assays exhibited high specificities (98.6%) when tested against a large animal fecal reference library and were highly abundant in raw sewage and sewage impacted water samples. In addition, CPQ_056 and CPQ_064 assay performance was compared to HF183/BacR287 and HumM2 methods in paired experiments. Findings confirm viral crAssphage qPCR assays perform at a similar level to well established bacterial human-associated fecal source identification technologies. These new viral based assays could become important water quality management and research tools. To inform the public.

  12. Comprehensive identification of essential Staphylococcus aureus genes using Transposon-Mediated Differential Hybridisation (TMDH

    Directory of Open Access Journals (Sweden)

    Burgis Timothy A

    2009-07-01

    Full Text Available Abstract Background In recent years there has been an increasing problem with Staphylococcus aureus strains that are resistant to treatment with existing antibiotics. An important starting point for the development of new antimicrobial drugs is the identification of "essential" genes that are important for bacterial survival and growth. Results We have developed a robust microarray and PCR-based method, Transposon-Mediated Differential Hybridisation (TMDH, that uses novel bioinformatics to identify transposon inserts in genome-wide libraries. Following a microarray-based screen, genes lacking transposon inserts are re-tested using a PCR and sequencing-based approach. We carried out a TMDH analysis of the S. aureus genome using a large random mariner transposon library of around a million mutants, and identified a total of 351 S. aureus genes important for survival and growth in culture. A comparison with the essential gene list experimentally derived for Bacillus subtilis highlighted interesting differences in both pathways and individual genes. Conclusion We have determined the first comprehensive list of S. aureus essential genes. This should act as a useful starting point for the identification of potential targets for novel antimicrobial compounds. The TMDH methodology we have developed is generic and could be applied to identify essential genes in other bacterial pathogens.

  13. [Comparison of the clinical performance of the ECLusys HBsAg II assay with the Lumipulse f and HISCL 2000-i HBsAg screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-02-01

    We compared the ECLusys HBsAgII (ECL HBsAg) assay to the Lumipulse Forte (LPf HBsAg) and HISCL (HIS HBsAg) assays. Measurement of dilution panels for which the WHO HBsAg international reference panel was the parent specimen revealed that the ECL and HIS assays enabled detection to a theoretical level of 0.04 IU/mL, whereas the LPf assay enabled detection to a level of 0.08 IU/mL. In a specificity test using high RF positive specimens (n = 33), pregnancy specimens (n = 35), cytomegalovirus antibody positive specimens (n = 36), and high M protein positive specimens (n = 21) that were confirmed negative for HBsAg by the LPf assay, negative results were obtained for all specimens on the HIS assay, but the ECL assay yielded a positive result for one of the high RF positive specimens. This individual was suggested on further testing to be an HBV carrier who was strongly positive for HBc antibody. In HBsAg mutants detection test, the detection rate was 92.3% with the ECL assay and 69.2% with the HIS assay. In a correlation test using routinely collected clinical specimens (n = 155), including positive stock specimens, aside from the one case where the LPf assay gave a negative result but both the ECL and HIS assays gave positive results, all of the results were consistent for all specimens. The above results confirmed that the ECL assay is both highly sensitive and specific, and also enables a high rate of HBsAg mutant detection.

  14. Radioimmunoassay screening and GC/MS confirmation of whole blood samples for drugs of abuse

    Energy Technology Data Exchange (ETDEWEB)

    Spiehler, V.R.; Sedgwick, P.

    From 1981 to 1984, an average of 300 radioimmunoassay screens on whole blood were performed each week in the authors laboratory. Most samples were screened for opiates phencyclidine and its analogs, barbiturates, and cocaine or its metabolite benzoylecgonine. A commercially available radioimmunoassay was used with modifications to facilitate screening of whole blood. Increasing sample size increased the sensitivity of the assay. Changing reagent concentration (1:1 dilution), incubation time, sample matrix (water, urine, or blood), or fraction counted (precipitate or supernatant) did not affect the utility of the standard curve or the sensitivity of the assay. All positive results for phencyclidine, opiates, cocaine, and related compounds were confirmed by GC/MA. Barbiturate positives were confirmed by UV spectrophotometry.

  15. Introgression of tomato chromosomes into the potato genome : an analysis through molecular marker and in situ hybridisation techniques = [Introgressie van tomatenchromosomen in het aardappelgenoom : een analyse met behulp van moleculaire merker en in situ hybridisatie technieken

    NARCIS (Netherlands)

    Garriga Caldere, F.

    1998-01-01

    Transfer of alien chromosomes and genes across intergeneric boundaries can be useful not only for the introgression of desirable characters but also for fundamental genetic studies. The successful demonstration of hybridisation of potato ( Solanum tuberosum ) and tomato

  16. [Comparison of the clinical performance of the ECLusys HIV combi assay with the Lumipulse f and HISCL 2000-i HIV-1/2 ab screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-04-01

    We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.

  17. Activity-Based Detection and Bioanalytical Confirmation of a Fatal Carfentanil Intoxication

    Directory of Open Access Journals (Sweden)

    Annelies Cannaert

    2018-05-01

    Full Text Available Carfentanil, one of the most potent opioids known, has recently been reported as a contaminant in street heroin in the United States and Europe, and is associated with an increased number of life-threatening emergency department admissions and deaths. Here, we report on the application of a novel in vitro opioid activity reporter assay and a sensitive bioanalytical assay in the context of a fatal carfentanil intoxication, revealing the highest carfentanil concentrations reported until now. A 21-year-old male was found dead at home with a note stating that he had taken carfentanil with suicidal intentions. A foil bag and plastic bag labeled “C.50” were found at the scene. These bags were similar to a sample obtained by the Belgian Early Warning System on Drugs from a German darknet shop and to those found in the context of a fatality in Norway. Blood, urine and vitreous, obtained during autopsy, were screened with a newly developed in vitro opioid activity reporter assay able to detect compounds based on their μ-opioid receptor activity rather than their chemical structure. All extracts showed strong opioid activity. Results were confirmed by a bioanalytical assay, which revealed extremely high concentrations for carfentanil and norcarfentanil. It should be noted that carfentanil concentrations are typically in pg/mL, but here they were 92 ng/mL in blood, 2.8 ng/mL in urine, and 23 ng/mL in vitreous. The blood and vitreous contained 0.532 and 0.300 ng/mL norcarfentanil, respectively. No norcarfentanil was detected in urine. This is the first report where a novel activity-based opioid screening assay was successfully deployed in a forensic case. Confirmation and quantification using a validated bioanalytical procedure revealed the, to our knowledge, highest carfentanil concentrations reported in humans so far.

  18. Evaluation of environmental genotoxicity by comet assay in Columba livia.

    Science.gov (United States)

    González-Acevedo, Anahi; García-Salas, Juan A; Gosálvez, Jaime; Fernández, José Luis; Dávila-Rodríguez, Martha I; Cerda-Flores, Ricardo M; Méndez-López, Luis F; Cortés-Gutiérrez, Elva I

    2016-01-01

    The concentrations of recognized or suspected genotoxic and carcinogenic agents found in the air of large cities and, in particular, developing countries, have raised concerns about the potential for chronic health effects in the populations exposed to them. The biomonitoring of environmental genotoxicity requires the selection of representative organisms as "sentinels," as well as the development of suitable and sensitive assays, such as those aimed at assessing DNA damage. The aim of this study was to evaluate DNA damage levels in erythrocytes from Columba livia living in the metropolitan area of Monterrey, Mexico, compared with control animals via comet assay, and to confirm the results via Micronuclei test (MN) and DNA breakage detection-fluorescence in situ hybridization (DBD-FISH). Our results showed a significant increase in DNA migration in animals from the area assayed compared with that observed in control animals sampled in non-contaminated areas. These results were confirmed by MN test and DBD-FISH. In conclusion, these observations confirm that the examination of erythrocytes from Columba livia via alkaline comet assay provides a sensitive and reliable end point for the detection of environmental genotoxicants.

  19. Chromogenic in situ hybridisation for the assessment of HER2 status in breast cancer: an international validation ring study

    Science.gov (United States)

    van de Vijver, Marc; Bilous, Michael; Hanna, Wedad; Hofmann, Manfred; Kristel, Petra; Penault-Llorca, Frédérique; Rüschoff, Josef

    2007-01-01

    Introduction Before any new methodology can be introduced into the routine diagnostic setting it must be technically validated against the established standards. To this end, a ring study involving five international pathology laboratories was initiated to validate chromogenic in situ hybridisation (CISH) against fluorescence in situ hybridisation (FISH) and immunohistochemistry (IHC) as a test for assessing human epidermal growth factor receptor 2 (HER2) status in breast cancer. Methods Each laboratory performed CISH, FISH and IHC on its own samples. Unstained sections from each case were also sent to another participating laboratory for blinded retesting by CISH ('outside CISH'). Results A total of 211 invasive breast carcinoma cases were tested. In 76 cases with high amplification (HER2/CEP17 ratio >4.0) by FISH, 73 cases (96%) scored positive (scores ≥ 6) by 'outside CISH'. For FISH-negative cases (HER2/CEP17 ratio CISH scores indicating no amplification (score ≤ 5), and only three cases were positive by CISH; in the three remaining cases, no CISH result could be obtained. For cases with low-level amplification using FISH (HER2/CEP17 ratio 2.0–4.0), 20 of 35 had CISH scores indicating gene amplification. Inter-laboratory concordance was also very high: 95% for normal HER2 copy number (1–5 copies); and 92% for cases with HER2 copy numbers ≥ 6. CISH intra-laboratory concordance with IHC was 92% for IHC-negative cases (IHC 0/1+) and 91% for IHC 3+ cases. Among IHC 2+ cases, CISH was 100% concordant with samples showing high amplification by FISH, and 94% concordant with FISH-negative samples. Conclusion These results show that CISH inter- and intra-laboratory concordance to FISH and IHC is very high, even in equivocal IHC 2+ cases. Therefore, we conclude that CISH is a methodology that is a viable alternative to FISH in the HER2 testing algorithm. PMID:17922920

  20. Quantitative multiplex quantum dot in-situ hybridisation based gene expression profiling in tissue microarrays identifies prognostic genes in acute myeloid leukaemia

    Energy Technology Data Exchange (ETDEWEB)

    Tholouli, Eleni [Department of Haematology, Manchester Royal Infirmary, Oxford Road, Manchester, M13 9WL (United Kingdom); MacDermott, Sarah [The Medical School, The University of Manchester, Oxford Road, M13 9PT Manchester (United Kingdom); Hoyland, Judith [School of Biomedicine, Faculty of Medical and Human Sciences, The University of Manchester, Oxford Road, M13 9PT Manchester (United Kingdom); Yin, John Liu [Department of Haematology, Manchester Royal Infirmary, Oxford Road, Manchester, M13 9WL (United Kingdom); Byers, Richard, E-mail: richard.byers@cmft.nhs.uk [School of Cancer and Enabling Sciences, Faculty of Medical and Human Sciences, The University of Manchester, Stopford Building, Oxford Road, M13 9PT Manchester (United Kingdom)

    2012-08-24

    Highlights: Black-Right-Pointing-Pointer Development of a quantitative high throughput in situ expression profiling method. Black-Right-Pointing-Pointer Application to a tissue microarray of 242 AML bone marrow samples. Black-Right-Pointing-Pointer Identification of HOXA4, HOXA9, Meis1 and DNMT3A as prognostic markers in AML. -- Abstract: Measurement and validation of microarray gene signatures in routine clinical samples is problematic and a rate limiting step in translational research. In order to facilitate measurement of microarray identified gene signatures in routine clinical tissue a novel method combining quantum dot based oligonucleotide in situ hybridisation (QD-ISH) and post-hybridisation spectral image analysis was used for multiplex in-situ transcript detection in archival bone marrow trephine samples from patients with acute myeloid leukaemia (AML). Tissue-microarrays were prepared into which white cell pellets were spiked as a standard. Tissue microarrays were made using routinely processed bone marrow trephines from 242 patients with AML. QD-ISH was performed for six candidate prognostic genes using triplex QD-ISH for DNMT1, DNMT3A, DNMT3B, and for HOXA4, HOXA9, Meis1. Scrambled oligonucleotides were used to correct for background staining followed by normalisation of expression against the expression values for the white cell pellet standard. Survival analysis demonstrated that low expression of HOXA4 was associated with poorer overall survival (p = 0.009), whilst high expression of HOXA9 (p < 0.0001), Meis1 (p = 0.005) and DNMT3A (p = 0.04) were associated with early treatment failure. These results demonstrate application of a standardised, quantitative multiplex QD-ISH method for identification of prognostic markers in formalin-fixed paraffin-embedded clinical samples, facilitating measurement of gene expression signatures in routine clinical samples.

  1. Culture confirmation of tuberculosis cases in Birmingham, UK.

    Science.gov (United States)

    Hayer, Kalbir S; Sitch, Alice J; Dedicoat, Martin; Wood, Annette L

    2013-10-01

    The proportion of culture-confirmed tuberculosis (TB) cases in Birmingham had gradually decreased to less than 65% in 2008. Reasons for this were unclear, therefore this study assessed diagnostic methods used for confirming TB and reviewed factors involved in positive culture. A cross-sectional study was carried out. A list of notified TB cases for Birmingham in those aged 16 y and over in 2009 was collated. Where no positive culture was recorded, further data were collected from hospital databases and case notes. Of 449 TB cases, 419 (93%) had samples taken for culture testing. Of all cases, 309 (69%) were confirmed by culture testing; of those receiving culture testing, 73% were confirmed. Pulmonary TB was identified as a predictor of positive culture in both the unadjusted and adjusted analyses: odds ratio (OR) 2.05, 95% confidence interval (CI) 1.32-3.19, and OR 2.32, 95% CI 1.29-4.17, respectively. Gender, age, ethnicity, UK born, and treatment delay were not significantly associated with positive culture. Of 140 cases not confirmed by culture, 129 (92%) had their diagnosis supported by at least one other test. The vast majority of TB cases had microbiological specimens taken to help confirm the disease. Furthermore, culture confirmation rates in Birmingham were meeting national targets in 2009. However culture confirmation rates were significantly lower in extrapulmonary TB, therefore further work is suggested in this group. The role of other investigations (e.g. interferon-gamma release assay (IGRA), Mantoux) is unclear. Further collaboration between clinicians, histopathologists, and microbiologists is advised to ensure samples are sent appropriately and culture confirmation is optimized.

  2. Molecular Confirmation of Salmonella typhimuriumin Poultry from Kathmandu Valley

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar Adhikari

    2018-05-01

    Full Text Available A prevalence study was carried to isolate Salmonella typhimurium from blood (n= 50 and gut samples (n=100 of poultry in Kathmandu valley during early 2016. Salmonella typhimurium bacteria isolated in the selective media were biochemically confirmed based on Bergey’s Manual. Two sets of oligonucleotide primers-the genus specific 16S rRNA and the organism specific invA were employed for molecular level confirmation by the Polymerase Chain Reaction (PCR assay. The amplified fragments in 1% agarose gel observed at 406bp and 285bp, respectively confirmed the isolates to be Salmonella typhimurium. Of 150 samples tested, Salmonella typhimurium were isolated from 49 samples, among which nine were from blood (18% and forty from the gut (40%. The present result indicated an alarmingly high level of Salmonella typhimurium, which can result inzoonotic infection in humans owing to increased contact with poultry and consumption of poultry products in the Kathmandu valley.

  3. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies; Assay development and evaluation in blood transfusion practice

    Energy Technology Data Exchange (ETDEWEB)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J. (Medical School, Manchester (United Kingdom). Department of Medical microbiology, Virology Unit); Morell, G. (Regional Blood Transfusion Centre, manchester (United Kingdom))

    1990-03-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 (human cytomegalovirus (CMV)) has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab.

  4. The evaluation of a user-friendly lateral flow assay for the serodiagnosis of human brucellosis in Kazakhstan.

    Science.gov (United States)

    Mizanbayeva, Sulushash; Smits, Henk L; Zhalilova, Katya; Abdoel, Theresia H; Kozakov, Stanislaw; Ospanov, Kenes S; Elzer, Philip H; Douglas, James T

    2009-09-01

    Serum samples from all patients with culture-confirmed brucellosis including those with chronic disease from Kazakhstan tested positive in the serum agglutination test for titers > or = 1:25 and reacted in the Brucella immunoglobulin M/immunoglobulin G lateral flow assay (LFA) confirming the high sensitivity of these assays. The strong reactivity in the LFA observed for the majority (92.1%) of the samples from the patients with culture-confirmed brucellosis together with the user-friendliness of the assay procedure makes the LFA ideal for the confirmation of brucellosis in endemic areas in Kazakhstan. The Rose Bengal test lacked sensitivity in particular for patients with chronic brucellosis therefore limiting its value as a quick screening assay. The study emphasizes the importance of the LFA as a useful, rapid, and easy-to-perform tool in the diagnostic testing of brucellosis.

  5. Molecular Confirmation of Trypanosoma evansi and Babesia bigemina in Cattle from Lower Egypt

    Directory of Open Access Journals (Sweden)

    Mahmoud M. Elhaig, Abdelfattah Selim, Mohamed M. Mahmoud and Eman K El-Gayar

    2016-11-01

    Full Text Available Trypanosomosis and babesiosis are economically important vector-borne diseases for animal health and productivity in developing countries. In Egypt, molecular epidemiological surveys on such diseases are scarce. In the present study, we examined 475 healthy and 25 clinically diagnosed cattle from three provinces in Lower Egypt, for Trypanosoma (T. and Babesia (B. infections using an ITS1 PCR assay that confirmed Trypanosoma species presence and an 18S rRNA assay that detected B. bigemina. Results confirmed Trypanosoma spp. and B. bigemina presence in 30.4% and 11% individuals, respectively, with eight animals (1.6% being co-infected with both hemoparasites. Subsequent type-specific PCRs revealed that all Trypanosoma PCR positive samples corresponded to T. evansi and that none of the animals harboured T. brucei gambiense or T. brucei rhodesiense. Nucleotide sequencing of the variable surface glycoprotein revealed the T. evansi cattle strain to be most closely related (99% nucleotide sequence identity to strains previously detected in dromedary camels in Egypt, while the 18S rRNA gene phylogeny confirmed the presence of a unique B. bigemina haplotype closely related to strains from Turkey and Brazil. Statistically significant differences in PCR prevalence were noted with respect to gender, clinical status and locality. These results confirm the presence of high numbers of carrier animals and signal the need for expanded surveillance and control efforts.

  6. St. Eunan's Nursing and Convalescent Home, Rough Park, Ramelton Road, Letterkenny, Donegal.

    LENUS (Irish Health Repository)

    Menton, John F

    2007-01-01

    BACKGROUND: Noroviruses are the most common cause of non-bacterial gastroenteritis. Improved detection methods have seen a large increase in the number of human NoV genotypes in the last ten years. The objective of this study was to develop a fast method to detect, quantify and genotype positive NoV samples from Irish hospitals. RESULTS: A real-time RT-PCR assay and a Reverse Line Blot Hybridisation assay were developed based on the ORF1-ORF2 region. The sensitivity and reactivity of the two assays used was validated using a reference stool panel containing 14 NoV genotypes. The assays were then used to investigate two outbreaks of gastroenteritis in two Irish hospitals. 56 samples were screened for NoV using a real-time RT-PCR assay and 26 samples were found to be positive. Genotyping of these positive samples found that all positives belonged to the GII\\/4 variant of NoV. CONCLUSION: The combination of the Real-time assay and the reverse line blot hybridisation assay provided a fast and accurate method to investigate a NoV associated outbreak. It was concluded that the predominant genotype circulating in these Irish hospitals was GII\\/4 which has been associated with the majority of NoV outbreaks worldwide. The assays developed in this study are useful tools for investigating NoV infection.

  7. Monitoring and characterisation of bacteria in corroding district heating systems using fluorescence in situ hybridisation and microautoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Kjellerup, B.V. [Danish Technological Institute, Teknologiparken (Denmark). Dept. of Environment; Aalborg University (Denmark). Dept. of Environmental Engineering; Olesen, B.H.; Frolund, B. [Danish Technological Institute, Teknologiparken (Denmark). Dept. of Environment; Nielsen, J.L.; Nielsen, P.H. [Aalborg University (Denmark). Dept. of Environmental Engineering; Odum, S. [CTR I/S, Frederiksberg (Denmark)

    2003-07-01

    Presence of biofilm and biocorrosion has been observed in Danish district heating (DH) systems despite very good water quality that was expected to prevent significant microbial growth. The microbiological water quality was investigated in order to identify the dominating bacterial groups on surfaces with corrosion problems. Water samples from 29 DH systems were investigated for the total number of bacteria and presence of sulphate reducing bacteria (SRBs). SRBs were found to be present in more than 80% of the DH systems. The microbial population in samples from 2 DH systems (biofilm from a test coupon and an in situ sample from a heat exchanger) was investigated with fluorescence in situ hybridisation, and the results showed significant differences in population composition. Betaproteobacteria was the dominant population in both samples. SRBs were present in both samples but were most numerous in the biofilm from the test coupon. Examination of functional groups based on uptake of radiolabelled acetate (microautoradiography) showed presence of both aerobic and anaerobic bacteria despite the fact that oxygen is not anticipated in DH systems. (author)

  8. Intra-familial comparison of supragingival dental plaque microflora using the checkerboard DNA-DNA hybridisation technique.

    Science.gov (United States)

    Mannaa, Alaa; Carlén, Anette; Dahlén, Gunnar; Lingström, Peter

    2012-12-01

    The aims of the present study were to correlate the quantified supragingival plaque bacteria between mothers and their children and identify possible microbial associations. A total of 86 mothers and their 4- to 6-year-old and 12- to 16-year-old children participated. Pooled supragingival plaque samples were obtained from interproximal sites between teeth 16/15, 25/26, 35/36 and 46/45 in mothers and older children and teeth 55/54, 64/65, 74/75 and 85/84 in younger children. All the samples were individually analysed for their content of 18 bacterial strains using checkerboard DNA-DNA hybridisation (whole genomic probes). Microbial associations were sought using cluster analysis (dendrogram) for all three age groups together, while community ordination techniques were used for each of the three groups separately. Three complexes were formed from the dendrogram in addition to associations between these complexes and remaining bacterial strains. Principal component analysis results were similar in all three groups. The correlation analyses of bacterial counts between mothers and their children showed a significant association for most of the bacterial strains (pplaque microbiota are correlated between mothers and their children. In addition, similar supragingival plaque microbial associations are present in family members.. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. A Cross-Reactivity of Fenofibric Acid With MDMA DRI Assay.

    Science.gov (United States)

    Bugier, Sarah; Garcia-Hejl, Carine; Vest, Philippe; Plantamura, Julie; Chianea, Denis; Renard, Christophe

    2016-09-01

    Within the framework of routine fitness examinations, French Air Force military crew underwent urine testing for 3,4 methylenedioxymetamphetamine (MDMA [ecstasy]). The cross-reactivity of a dyslipidemic drug, fenofibrate, with an MDMA immunoassay was studied and confirmed on a large population sample. A 3-year retrospective study was performed on the MDMA DRI Ecstasy Assay on the Unicel DXC 600. In the event of positive test result, a confirmatory testing was carried out by gas chromatography/mass spectrometry (GC/MS) to establish the presence of MDMA. When analysis by GC/MS did not confirm the presence of MDMA, a false-positive result was suspected and the samples were analyzed by high-performance liquid chromatography-mass spectrometry to identify a potential interfering substance. A total of 15,169 urine samples, from 7,803 patients, were tested for 3 years. Of the tested samples, 22 (0.15%) were positive by DRI Ecstasy Assay. None of them were positive by GC/MS. A cross-reactivity of fenofibrate's metabolite with MDMA using this assay was systematically found. Fenofibrate's interference with MDMA immunoassay was confirmed. Fenofibrate being widely prescribed, physicians had to be alerted that this treatment could lead to false-positive results. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  10. Multiclass determination and confirmation of antibiotic residues in honey using LC-MS/MS.

    Science.gov (United States)

    Lopez, Mayda I; Pettis, Jeffery S; Smith, I Barton; Chu, Pak-Sin

    2008-03-12

    A multiclass method has been developed for the determination and confirmation in honey of tetracyclines (chlortetracycline, doxycycline, oxytetracycline, and tetracycline), fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, and sarafloxacin), macrolides (tylosin), lincosamides (lincomycin), aminoglycosides (streptomycin), sulfonamides (sulfathiazole), phenicols (chloramphenicol), and fumagillin residues using liquid chromatography tandem mass spectrometry (LC-MS/MS). Erythromycin (a macrolide) and monensin (an ionophore) can be detected and confirmed but not quantitated. Honey samples (approximately 2 g) are dissolved in 10 mL of water and centrifuged. An aliquot of the supernatant is used to determine streptomycin. The remaining supernatant is filtered through a fine-mesh nylon fabric and cleaned up by solid phase extraction. After solvent evaporation and sample reconstitution, 15 antibiotics are assayed by LC-MS/MS using electrospray ionization (ESI) in positive ion mode. Afterward, chloramphenicol is assayed using ESI in negative ion mode. The method has been validated at the low part per billion levels for most of the drugs with accuracies between 65 and 104% and coefficients of variation less than 17%. The evaluation of matrix effects caused by honey of different floral origin is presented.

  11. Comparison of two commercial carbapenemase gene confirmatory assays in multiresistant Enterobacteriaceae and Acinetobacter baumannii-complex.

    Science.gov (United States)

    Rösner, Stephan; Gehlweiler, Kevin; Küsters, Uta; Kolbert, Mathias; Hübner, Kirsten; Pfennigwerth, Niels; Mack, Dietrich

    2018-01-01

    Multidrug-resistant Gram-negative bacilli (MDR-GNB) producing carbapenemases are increasing at an alarming speed. Rapid confirmation of carbapenemase type will be an important diagnostic step in clinical microbiology laboratories not only to reduce the risk of transmissions but also for optimising antibiotic therapy in the future. We compared diagnostic reliability of two commercially available molecular assays (Check-Direct CPE vs. AID line probe assay) for detection and typing of carbapenemase genes in 80 well-characterized isolates of MDR-GNB. Respective strains were isolated in various clinical specimens at our clinical microbiology laboratory. The reference standard included confirmation of carbapenemase-production at the molecular level at the German National Reference Laboratory for Multidrug-resistant Gram-negative bacteria (Ruhr-University Bochum, Germany). 53 Enterobacteriaceae and 27 members of the A. baumannii-complex were used in this study. The tested assays appeared highly reliable to confirm carbapenemase-producing Enterobacteriaceae (CPE) with respective sensitivities of 97.7%, but are currently unsuitable for analysis of members of the A. baumannii-complex. Both assays are easy to perform and rapid tools for confirmation and typing of the most common carbapenemase genes in Enterobacteriaceae. Implementation should be possible for any clinical microbiology laboratory with Check-Direct CPE being easier to handle and having less technological requirements.

  12. Comparison of two commercial carbapenemase gene confirmatory assays in multiresistant Enterobacteriaceae and Acinetobacter baumannii-complex.

    Directory of Open Access Journals (Sweden)

    Stephan Rösner

    Full Text Available Multidrug-resistant Gram-negative bacilli (MDR-GNB producing carbapenemases are increasing at an alarming speed. Rapid confirmation of carbapenemase type will be an important diagnostic step in clinical microbiology laboratories not only to reduce the risk of transmissions but also for optimising antibiotic therapy in the future. We compared diagnostic reliability of two commercially available molecular assays (Check-Direct CPE vs. AID line probe assay for detection and typing of carbapenemase genes in 80 well-characterized isolates of MDR-GNB. Respective strains were isolated in various clinical specimens at our clinical microbiology laboratory. The reference standard included confirmation of carbapenemase-production at the molecular level at the German National Reference Laboratory for Multidrug-resistant Gram-negative bacteria (Ruhr-University Bochum, Germany. 53 Enterobacteriaceae and 27 members of the A. baumannii-complex were used in this study. The tested assays appeared highly reliable to confirm carbapenemase-producing Enterobacteriaceae (CPE with respective sensitivities of 97.7%, but are currently unsuitable for analysis of members of the A. baumannii-complex. Both assays are easy to perform and rapid tools for confirmation and typing of the most common carbapenemase genes in Enterobacteriaceae. Implementation should be possible for any clinical microbiology laboratory with Check-Direct CPE being easier to handle and having less technological requirements.

  13. High resolution array-based comparative genomic hybridisation of medulloblastomas and supra-tentorial primitive neuroectodermal tumours

    Science.gov (United States)

    McCabe, Martin Gerard; Ichimura, Koichi; Liu, Lu; Plant, Karen; Bäcklund, L Magnus; Pearson, Danita M; Collins, Vincent Peter

    2010-01-01

    Medulloblastomas and supratentorial primitive neuroectodermal tumours are aggressive childhood tumours. We report our findings using array comparative genomic hybridisation (CGH) on a whole-genome BAC/PAC/cosmid array with a median clone separation of 0.97Mb to study 34 medulloblastomas and 7 supratentorial primitive neuroectodermal tumours. Array CGH allowed identification and mapping of numerous novel small regions of copy number change to genomic sequence, in addition to the large regions already known from previous studies. Novel amplifications were identified, some encompassing oncogenes, MYCL1, PDGFRA, KIT and MYB, not previously reported to show amplification in these tumours. In addition, one supratentorial primitive neuroectodermal tumour had lost both copies of the tumour suppressor genes CDKN2A & CDKN2B. Ten medulloblastomas had findings suggestive of isochromosome 17q. In contrast to previous reports using conventional CGH, array CGH identified three distinct breakpoints in these cases: Ch 17: 17940393-19251679 (17p11.2, n=6), Ch 17: 20111990-23308272 (17p11.2-17q11.2, n=4) and Ch 17: 38425359-39091575 (17q21.31, n=1). Significant differences were found in the patterns of copy number change between medulloblastomas and supratentorial primitive neuroectodermal tumours, providing further evidence that these tumours are genetically distinct despite their morphological and behavioural similarities. PMID:16783165

  14. Genotoxicity testing: Comparison of the γH2AX focus assay with the alkaline and neutral comet assays.

    Science.gov (United States)

    Nikolova, Teodora; Marini, Federico; Kaina, Bernd

    2017-10-01

    Genotoxicity testing relies on the quantitative measurement of adverse effects, such as chromosome aberrations, micronuclei, and mutations, resulting from primary DNA damage. Ideally, assays will detect DNA damage and cellular responses with high sensitivity, reliability, and throughput. Several novel genotoxicity assays may fulfill these requirements, including the comet assay and the more recently developed γH2AX assay. Although they are thought to be specific for genotoxicants, a systematic comparison of the assays has not yet been undertaken. In the present study, we compare the γH2AX focus assay with the alkaline and neutral versions of the comet assay, as to their sensitivities and limitations for detection of genetic damage. We investigated the dose-response relationships of γH2AX foci and comet tail intensities at various times following treatment with four prototypical genotoxicants, methyl methanesulfonate (MMS), N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), mitomycin C, and hydrogen peroxide (H 2 O 2 ) and we tested whether there is a correlation between the endpoints, i.e., alkali-labile sites and DNA strand breaks on the one hand and the cell's response to DNA double-strand breaks and blocked replication forks on the other. Induction of γH2AX foci gave a linear dose response and all agents tested were positive in the assay. The increase in comet tail intensity was also a function of dose; however, mitomycin C was almost completely ineffective in the comet assay, and the doses needed to achieve a significant effect were somewhat higher for some treatments in the comet assay than in the γH2AX foci assay, which was confirmed by threshold analysis. There was high correlation between tail intensity and γH2AX foci for MMS and H 2 O 2 , less for MNNG, and none for mitomycin C. From this we infer that the γH2AX foci assay is more reliable, sensitive, and robust than the comet assay for detecting genotoxicant-induced DNA damage. Copyright © 2017 Elsevier

  15. Development of a heavy metals enzymatic-based assay using papain

    International Nuclear Information System (INIS)

    Shukor, Yunus; Baharom, Nor Azlan; Rahman, Fadhil Abd.; Abdullah, Mohd. Puad; Shamaan, Nor Aripin; Syed, Mohd. Arif

    2006-01-01

    A heavy metals enzymatic-based assay using papain was developed. Papain was assayed using the Casein-coomassie-dye-binding assay. The assay is sensitive to several heavy metals. The IC 50 (concentration of toxicant giving 50% inhibition) of Hg 2+ , Ag 2+ , Pb 2 , Zn 2+ is 0.39, 0.40, 2.16, 2.11 mg l -1 , respectively. For Cu 2+ and Cd 2+ the LOQ (limits of quantitation) is 0.004 and 0.1 mg l -1 , respectively. The IC 50 and LOQ values were found to be generally comparable to several other enzymatic and bioassays tests such as: immobilized urease, 15-min Microtox TM , 48 h Daphnia magna, and 96 h Rainbow trout. The papain assay is xenobiotics tolerant, has a wide pH for optimum activity, is temperature stable, and has a relatively quick assay time. The papain assay was used to identify polluted water samples from industrial sources in Penang, Malaysia. We found one site where the assay gave a positive toxic response. The toxicity of the site was confirmed using Atomic Emission Spectrometry analysis

  16. Herpes simplex encephalitis: MRI findings in two cases confirmed by polymerase chain reaction assay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.W.; Kim, I.O.; Kim, W.S.; Yeon, K.M. [Dept. of Radiology and the Institute of Radiation Medicine, Seoul National University Hospital, Seoul (Korea); Lee, H.-J.; Hwang, Y.S. [Dept. of Paediatrics, Seoul National University College of Medicine, Seoul (Korea)

    2001-09-01

    Herpes simplex virus (HSV) type I causes a fulminant necrotising meningoencephalitis distinguished from other encephalitides by its focal and often haemorrhagic nature. Specific antiviral therapy with acyclovir can significantly improve the prognosis. We present MRI findings of two cases of herpes simplex encephalitis (HSE) confirmed by PCR analysis, focusing on the serial changes after acyclovir therapy: gyral swelling, high signal intensity on T2-weighted images in the subfrontal region, temporal lobe and insula in the initial stage, then regional extension with enhancement and haemorrhage despite appropriate acyclovir therapy, and finally encephalomalacia and brain atrophy. (orig.)

  17. Herpes simplex encephalitis: MRI findings in two cases confirmed by polymerase chain reaction assay

    International Nuclear Information System (INIS)

    Lee, J.W.; Kim, I.O.; Kim, W.S.; Yeon, K.M.; Lee, H.-J.; Hwang, Y.S.

    2001-01-01

    Herpes simplex virus (HSV) type I causes a fulminant necrotising meningoencephalitis distinguished from other encephalitides by its focal and often haemorrhagic nature. Specific antiviral therapy with acyclovir can significantly improve the prognosis. We present MRI findings of two cases of herpes simplex encephalitis (HSE) confirmed by PCR analysis, focusing on the serial changes after acyclovir therapy: gyral swelling, high signal intensity on T2-weighted images in the subfrontal region, temporal lobe and insula in the initial stage, then regional extension with enhancement and haemorrhage despite appropriate acyclovir therapy, and finally encephalomalacia and brain atrophy. (orig.)

  18. Phenotypic and Genotypic Analysis of Newly Obtained Interspecific Hybrids in the Campanula Genus.

    Directory of Open Access Journals (Sweden)

    Anna-Catharina Röper

    Full Text Available Interspecific hybridisation creates new phenotypes within several ornamental plant species including the Campanula genus. We have employed phenotypic and genotypic methods to analyse and evaluate interspecific hybridisation among cultivars of four Campanula species, i.e. C. cochleariifolia, C. isophylla, C. medium and C. formanekiana. Hybrids were analysed using amplified fragment length polymorphism (AFLP, flow cytometry and biometrical measurements. Results of correlation matrices demonstrated heterogeneous phenotypes for the parental species, which confirmed our basic premise for new phenotypes of interspecific hybrids. AFLP assays confirmed the hybridity and identified self-pollinated plants. Limitation of flow cytometry analysis detection was observed while detecting the hybridity status of two closely related parents, e.g. C. cochleariiafolia × C. isophylla. Phenotypic characteristics such as shoot habitus and flower colour were strongly influenced by one of the parental species in most crosses. Rooting analysis revealed that inferior rooting quality occurred more often in interspecific hybrids than in the parental species. Only interspecific hybrid lines of C. formanekiana 'White' × C. medium 'Pink' showed a high rooting level. Phenotype analyses demonstrated a separation from the interspecific hybrid lines of C. formanekiana 'White' × C. medium 'Pink' to the other clustered hybrids of C. formanekiana and C. medium. In our study we demonstrated that the use of correlation matrices is a suitable tool for identifying suitable cross material. This study presents a comprehensive overview for analysing newly obtained interspecific hybrids. The chosen methods can be used as guidance for analyses for further interspecific hybrids in Campanula, as well as in other ornamental species.

  19. When Anthropogenic River Disturbance Decreases Hybridisation between Non-Native and Endemic Cyprinids and Drives an Ecomorphological Displacement towards Juvenile State in Both Species.

    Directory of Open Access Journals (Sweden)

    Emmanuel Corse

    Full Text Available Understanding the impact of non-native species on native species is a major challenge in molecular ecology, particularly for genetically compatible fish species. Invasions are generally difficult to study because their effects may be confused with those of environmental or human disturbances. Colonized ecosystems are differently impacted by human activities, resulting in diverse responses and interactions between native and non-native species. We studied the dynamics between two Cyprinids species (invasive Chondrostoma nasus and endemic Parachondrostoma toxostoma and their hybrids in 16 populations (from allopatric to sympatric situations and from little to highly fragmented areas corresponding to 2,256 specimens. Each specimen was assigned to a particular species or to a hybrid pool using molecular identification (cytochrome b and 41 microsatellites. We carried out an ecomorphological analysis based on size, age, body shape, and diet (gut vacuity and molecular fecal contents. Our results contradicted our initial assumptions on the pattern of invasion and the rate of introgression. There was no sign of underperformance for the endemic species in areas where hybridisation occurred. In the unfragmented zone, the introduced species was found mostly downstream, with body shapes similar to those in allopatric populations while both species were found to be more insectivorous than the reference populations. However, high level of hybridisation was detected, suggesting interactions between the two species during spawning and/or the existence of hybrid swarm. In the disturbed zone, introgression was less frequent and slender body shape was associated with diatomivorous behaviour, smaller size (juvenile characteristics and greater gut vacuity. Results suggested that habitat degradation induced similar ecomorphological trait changes in the two species and their hybrids (i.e. a transition towards a pedomorphic state where the invasive species is more

  20. Secretin, its discovery, and the introduction of the hormone concept

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik; de Muckadell, O B

    2000-01-01

    . The isolation and subsequent synthesis of secretin in the 1960s prepared the way for immunological techniques. Radioimmuno assays in the 1970s enabled demonstration of a direct endocrine role of secretin. Cloning and molecular hybridisation in the 1990s identified production site structure, precursor...

  1. Enhanced detection levels in a semi-automated sandwich ...

    African Journals Online (AJOL)

    A peptide nucleic acid (PNA) signal probe was tested as a replacement for a typical DNA oligonucleotidebased signal probe in a semi-automated sandwich hybridisation assay designed to detect the harmful phytoplankton species Alexandrium tamarense. The PNA probe yielded consistently higher fluorescent signal ...

  2. Confirmation bias in studies of nestmate recognition: a cautionary note for research into the behaviour of animals.

    Science.gov (United States)

    van Wilgenburg, Ellen; Elgar, Mark A

    2013-01-01

    Confirmation bias is a tendency of people to interpret information in a way that confirms their expectations. A long recognized phenomenon in human psychology, confirmation bias can distort the results of a study and thus reduce its reliability. While confirmation bias can be avoided by conducting studies blind to treatment groups, this practice is not always used. Surprisingly, this is true of research in animal behaviour, and the extent to which confirmation bias influences research outcomes in this field is rarely investigated. Here we conducted a meta-analysis, using studies on nestmate recognition in ants, to compare the outcomes of studies that were conducted blind with those that were not. Nestmate recognition studies typically perform intra- and inter colony aggression assays, with the a priori expectation that there should be little or no aggression among nestmates. Aggressive interactions between ants can include subtle behaviours such as mandible flaring and recoil, which can be hard to quantify, making these types of assays prone to confirmation bias. Our survey revealed that only 29% of our sample of 79 studies were conducted blind. These studies were more likely to report aggression among nestmates if they were conducted blind (73%) than if they were not (21%). Moreover, we found that the effect size between nestmate and non-nestmate treatment means is significantly lower in experiments conducted blind than those in which colony identity is known (1.38 versus 2.76). We discuss the implications of the impact of confirmation bias for research that attempts to obtain quantitative synthesises of data from different studies.

  3. Confirmation bias in studies of nestmate recognition: a cautionary note for research into the behaviour of animals.

    Directory of Open Access Journals (Sweden)

    Ellen van Wilgenburg

    Full Text Available Confirmation bias is a tendency of people to interpret information in a way that confirms their expectations. A long recognized phenomenon in human psychology, confirmation bias can distort the results of a study and thus reduce its reliability. While confirmation bias can be avoided by conducting studies blind to treatment groups, this practice is not always used. Surprisingly, this is true of research in animal behaviour, and the extent to which confirmation bias influences research outcomes in this field is rarely investigated. Here we conducted a meta-analysis, using studies on nestmate recognition in ants, to compare the outcomes of studies that were conducted blind with those that were not. Nestmate recognition studies typically perform intra- and inter colony aggression assays, with the a priori expectation that there should be little or no aggression among nestmates. Aggressive interactions between ants can include subtle behaviours such as mandible flaring and recoil, which can be hard to quantify, making these types of assays prone to confirmation bias. Our survey revealed that only 29% of our sample of 79 studies were conducted blind. These studies were more likely to report aggression among nestmates if they were conducted blind (73% than if they were not (21%. Moreover, we found that the effect size between nestmate and non-nestmate treatment means is significantly lower in experiments conducted blind than those in which colony identity is known (1.38 versus 2.76. We discuss the implications of the impact of confirmation bias for research that attempts to obtain quantitative synthesises of data from different studies.

  4. Evaluation of performance of human immunodeficiency virus antigen/antibody combination assays in Taiwan.

    Science.gov (United States)

    Chang, Chun-Kai; Kao, Cheng-Feng; Lin, Pi-Han; Huang, Hui-Lin; Ho, Shu-Yuan; Wong, Kuo-Chen; Lin, Bo-Chang; Yeh, Chang-Ching; Lee, Chia-Yeh; Kao, Chuan-Liang; Lee, Chun-Nan; Chang, Sui-Yuan; Yang, Jyh-Yuan

    2017-08-01

    The fourth-generation human immunodeficiency virus (HIV) combination assay, which can simultaneously detect the presence of anti-HIV antibody and HIV antigen, has been shown to shorten the window period in HIV diagnosis compared with the third-generation HIV antibody immunoassay. This study was aimed to determine the performance of HIV combination assays in Taiwan, where the HIV-1 seroprevalence is 0.007% and HIV-2 infection has never been reported. Performance of three fourth-generation HIV Ag/Ab combination assays (Dia.Pro, Wantai, and Bio-Rad) and one third-generation HIV Ab immunoassay (AxSYM HIV 1/2 gO) was assessed. A total of 152 specimens, including 86 confirmed HIV-seropositive and 66 HIV-seronegative samples, were used in the study. The sensitivity of four assays varied from 98.8% to 100%, and specificity varied from 98.5% to 100%. Performance of the 75 equivocal samples, the HIV status of which was confirmed later, in terms of negative prediction varied from 81.8% to 87.5%. The Bio-Rad and Dia.Pro assays exhibited higher sensitivity for the detection of p24 antigen among the three fourth-generation HIV combination assays. The three fourth-generation HIV Ag/Ab combination assays exhibited better sensitivity, specificity, and negative prediction than the third-generation HIV Ab immunoassay. Copyright © 2015. Published by Elsevier B.V.

  5. Versatile High-Throughput Fluorescence Assay for Monitoring Cas9 Activity.

    Science.gov (United States)

    Seamon, Kyle J; Light, Yooli K; Saada, Edwin A; Schoeniger, Joseph S; Harmon, Brooke

    2018-06-05

    The RNA-guided DNA nuclease Cas9 is now widely used for the targeted modification of genomes of human cells and various organisms. Despite the extensive use of Clustered Regularly Interspaced Palindromic Repeats (CRISPR) systems for genome engineering and the rapid discovery and engineering of new CRISPR-associated nucleases, there are no high-throughput assays for measuring enzymatic activity. The current laboratory and future therapeutic uses of CRISPR technology have a significant risk of accidental exposure or clinical off-target effects, underscoring the need for therapeutically effective inhibitors of Cas9. Here, we develop a fluorescence assay for monitoring Cas9 nuclease activity and demonstrate its utility with S. pyogenes (Spy), S. aureus (Sau), and C. jejuni (Cje) Cas9. The assay was validated by quantitatively profiling the species specificity of published anti-CRISPR (Acr) proteins, confirming the reported inhibition of Spy Cas9 by AcrIIA4 and Cje Cas9 by AcrIIC1 and no inhibition of Sau Cas9 by either anti-CRISPR. To identify drug-like inhibitors, we performed a screen of 189 606 small molecules for inhibition of Spy Cas9. Of 437 hits (0.2% hit rate), six were confirmed as Cas9 inhibitors in a direct gel electrophoresis secondary assay. The high-throughput nature of this assay makes it broadly applicable for the discovery of additional Cas9 inhibitors or the characterization of Cas9 enzyme variants.

  6. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies

    International Nuclear Information System (INIS)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J.

    1990-01-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 [human cytomegalovirus (CMV)] has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab

  7. Development and evaluation of a rapid dipstick assay for serodiagnosis of acute human brucellosis

    NARCIS (Netherlands)

    Smits, H. L.; Basahi, M. A.; Díaz, R.; Marrodan, T.; Douglas, J. T.; Rocha, A.; Veerman, J.; Zheludkov, M. M.; Witte, O. W.; de Jong, J.; Gussenhoven, G. C.; Goris, M. G.; van der Hoorn, M. A.

    1999-01-01

    A dipstick assay for the detection of brucella-specific immunoglobulin M antibodies was evaluated with 707 sera from 247 laboratory-confirmed brucellosis patients and 342 control sera from brucellosis-free individuals. These sera were collected from six different countries. The assay was found to be

  8. Principles of validation of diagnostic assays for infectious diseases

    International Nuclear Information System (INIS)

    Jacobson, R.H.

    1998-01-01

    Assay validation requires a series of inter-related processes. Assay validation is an experimental process: reagents and protocols are optimized by experimentation to detect the analyte with accuracy and precision. Assay validation is a relative process: its diagnostic sensitivity and diagnostic specificity are calculated relative to test results obtained from reference animal populations of known infection/exposure status. Assay validation is a conditional process: classification of animals in the target population as infected or uninfected is conditional upon how well the reference animal population used to validate the assay represents the target population; accurate predictions of the infection status of animals from test results (PV+ and PV-) are conditional upon the estimated prevalence of disease/infection in the target population. Assay validation is an incremental process: confidence in the validity of an assay increases over time when use confirms that it is robust as demonstrated by accurate and precise results; the assay may also achieve increasing levels of validity as it is upgraded and extended by adding reference populations of known infection status. Assay validation is a continuous process: the assay remains valid only insofar as it continues to provide accurate and precise results as proven through statistical verification. Therefore, the work required for validation of diagnostic assays for infectious diseases does not end with a time-limited series of experiments based on a few reference samples rather, to assure valid test results from an assay requires constant vigilance and maintenance of the assay, along with reassessment of its performance characteristics for each unique population of animals to which it is applied. (author)

  9. Use of laminar flow patterning for miniaturised biochemical assays

    DEFF Research Database (Denmark)

    Regenberg, Birgitte; Krühne, Ulrich; Beyer, M.

    2004-01-01

    Laminar flow in microfluidic chambers was used to construct low (one dimensional) density arrays suitable for miniaturized biochemical assays. By varying the ratio of flows of two guiding streams flanking a sample stream, precise focusing and positioning of the latter was achieved, and reactive s...... species carried in the sample stream were deposited on functionalized chip surfaces as discrete 50 mm wide lanes. Using different model systems we have confirmed the method's suitability for qualitative screening and quantification tasks in receptor-ligand assays, recording biotin...

  10. Emerging Technologies and Generic Assays for the Detection of Anti-Drug Antibodies

    Directory of Open Access Journals (Sweden)

    Michael A. Partridge

    2016-01-01

    Full Text Available Anti-drug antibodies induced by biologic therapeutics often impact drug pharmacokinetics, pharmacodynamics response, clinical efficacy, and patient safety. It is critical to assess the immunogenicity risk of potential biotherapeutics in producing neutralizing and nonneutralizing anti-drug antibodies, especially in clinical phases of drug development. Different assay methodologies have been used to detect all anti-drug antibodies, including ELISA, radioimmunoassay, surface plasmon resonance, and electrochemiluminescence-based technologies. The most commonly used method is a bridging assay, performed in an ELISA or on the Meso Scale Discovery platform. In this report, we aim to review the emerging new assay technologies that can complement or address challenges associated with the bridging assay format in screening and confirmation of ADAs. We also summarize generic anti-drug antibody assays that do not require drug-specific reagents for nonclinical studies. These generic assays significantly reduce assay development efforts and, therefore, shorten the assay readiness timeline.

  11. Implementation of External Quality Assurance Trials for Immunohistochemically Determined Breast Cancer Biomarkers in Germany

    OpenAIRE

    von Wasielewski, Reinhard; Krusche, Claudia A.; Rüschoff, Joseph; Fisseler-Eckhoff, Anette; Kreipe, Hans

    2008-01-01

    Besides typing and grading of breast cancer, Pathologists are involved in the determination of biomarkers, such as steroid hormone receptors and HER2, which are of utmost importance in adjuvant therapy. There have been concerns with regard to security and reproducibility of the biomarker assays done on tissue sections applying either immunohistochemistry or in-situ hybridisation. In order to assure the quality of these biomarker assays, a number of measures are required, among them external p...

  12. Analytical and Clinical Performance Evaluation of the Abbott Architect PIVKA Assay.

    Science.gov (United States)

    Ko, Dae-Hyun; Hyun, Jungwon; Kim, Hyun Soo; Park, Min-Jeong; Kim, Jae-Seok; Park, Ji-Young; Shin, Dong Hoon; Cho, Hyoun Chan

    2018-01-01

    Protein induced by vitamin K absence (PIVKA) is measured using various assays and is used to help diagnose hepatocellular carcinoma. The present study evaluated the analytical and clinical performances of the recently released Abbott Architect PIVKA assay. Precision, linearity, and correlation tests were performed in accordance with the Clinical Laboratory Standardization Institute guidelines. Sample type suitability was assessed using serum and plasma samples from the same patients, and the reference interval was established using sera from 204 healthy individuals. The assay had coefficients of variation of 3.2-3.5% and intra-laboratory variation of 3.6-5.5%. Linearity was confirmed across the entire measurable range. The Architect PIVKA assay was comparable to the Lumipulse PIVKA assay, and the plasma and serum samples provided similar results. The lower reference limit was 13.0 mAU/mL and the upper reference limit was 37.4 mAU/mL. The ability of the Architect PIVKA assay to detect hepatocellular carcinoma was comparable to that of the alpha-fetoprotein test and the Lumipulse PIVKA assay. The Architect PIVKA assay provides excellent analytical and clinical performance, is simple for clinical laboratories to adopt, and has improved sample type suitability that could broaden the assay's utility. © 2018 by the Association of Clinical Scientists, Inc.

  13. A Ploidy Difference Represents an Impassable Barrier for Hybridisation in Animals. Is There an Exception among Botiid Loaches (Teleostei: Botiidae?

    Directory of Open Access Journals (Sweden)

    Jörg Bohlen

    Full Text Available One of the most efficient mechanisms to keep animal lineages separate is a difference in ploidy level (number of whole genome copies, since hybrid offspring from parents with different ploidy level are functionally sterile. In the freshwater fish family Botiidae, ploidy difference has been held responsible for the separation of its two subfamilies, the evolutionary tetraploid Botiinae and the diploid Leptobotiinae. Diploid and tetraploid species coexist in the upper Yangtze, the Pearl River and the Red River basins in China. Interestingly, the species 'Botia' zebra from the Pearl River basin combines a number of morphological characters that otherwise are found in the diploid genus Leptobotia with morphological characters of the tetraploid genus Sinibotia, therefore the aim of the present study is to test weather 'B.' zebra is the result of a hybridisation event between species from different subfamilies with different ploidy level. A closer morphological examination indeed demonstrates a high similarity of 'B.' zebra to two co-occurring species, the diploid Leptobotia guilinensis and the tetraploid Sinibotia pulchra. These two species thus could have been the potential parental species in case of a hybrid origin of 'B.' zebra. The morphologic analysis further reveals that 'B.' zebra bears even the diagnostic characters of the genera Leptobotia (Leptobotiinae and Sinibotia (Botiinae. In contrast, a comparison of six allozyme loci between 'B.' zebra, L. guilinensis and S. pulchra showed only similarities between 'B.' zebra and S. pulchra, not between 'B.' zebra and L. guilinensis. Six specimens of 'B.' zebra that were cytogenetically analysed were tetraploid with 4n = 100. The composition of the karyotype (18% metacentric, 18% submetacentric, 36% subtelocentric and 28% acrocentric chromosomes differs from those of L. guilinensis (12%, 24%, 20% and 44% and S. pulchra (20%, 26%, 28% and 26%, and cannot be obtained by any combination of genomes from

  14. Determination of assay and impurities of gamma irradiated chloramphenicol in eye ointment

    International Nuclear Information System (INIS)

    Hong, L.; Altorfer, H.R.

    2005-01-01

    A sample preparation method was developed to isolate chloramphenicol and its radiolytic products from an oily ointment base. The isolation method suspended the eye ointment in n-hexane at 45 deg C, and isolated the target compounds as residue by centrifugation. It was found that the main element to ensure a satisfactory isolation was keeping the sample solution at 45 deg C during sample preparation. Linearity, precision, accuracy and suitability of the method were confirmed valid for both assay and impurity tests. This isolation method was ideal for assay, unique for extraction of unexpected and complex radiolysis products, and had a number of advantages compared to the pretreatment methods described in the United States Pharmacopoeia and British Pharmacopoeia, in terms of accuracy, precision, and easy handling. The effect of γ-irradiation on chloramphenicol eye ointment was studied by HPLC-DAD, after applying the developed sample preparation method. The present assay and impurity test methods with HPLC-DAD were confirmed to be suitable for irradiated chloramphenicol in eye ointment. (author)

  15. Automated immunoradiometric assay of thyrotrophin (TSH) in dried blood filter paper spots

    Energy Technology Data Exchange (ETDEWEB)

    John, R.; Woodhead, J.S. (Welsh National School of Medicine, Cardiff (UK))

    1982-11-10

    An immunoradiometric two-site assay for thyrotrophin (TSH) in dried blood filter paper spots is described. The assay is automated by means of the Kemtek 3000 automated immunoassay system. The technique uses a 6.0 mm disc punched from the dried blood samples collected as part of the screening programme for phenylketonuria. The method is sensitive and precise, and results correlate well with those obtained in TSH assays of serum samples. The procedure is rapid, results being available within 24 h of receipt of samples. Of 25204 specimens so far screened by this assay, 99.9% have TSH levels less than 15 mU/l. One false positive result has been obtained and six confirmed cases of neonatal hypothyroidism detected, giving a prevalence of 1 in 4200.

  16. WebaCGH: an interactive online tool for the analysis and display of array comparative genomic hybridisation data.

    Science.gov (United States)

    Frankenberger, Casey; Wu, Xiaolin; Harmon, Jerry; Church, Deanna; Gangi, Lisa M; Munroe, David J; Urzúa, Ulises

    2006-01-01

    Gene copy number variations occur both in normal cells and in numerous pathologies including cancer and developmental diseases. Array comparative genomic hybridisation (aCGH) is an emerging technology that allows detection of chromosomal gains and losses in a high-resolution format. When aCGH is performed on cDNA and oligonucleotide microarrays, the impact of DNA copy number on gene transcription profiles may be directly compared. We have created an online software tool, WebaCGH, that functions to (i) upload aCGH and gene transcription results from multiple experiments; (ii) identify significant aberrant regions using a local Z-score threshold in user-selected chromosomal segments subjected to smoothing with moving averages; and (iii) display results in a graphical format with full genome and individual chromosome views. In the individual chromosome display, data can be zoomed in/out in both dimensions (i.e. ratio and physical location) and plotted features can have 'mouse over' linking to outside databases to identify loci of interest. Uploaded data can be stored indefinitely for subsequent retrieval and analysis. WebaCGH was created as a Java-based web application using the open-source database MySQL. WebaCGH is freely accessible at http://129.43.22.27/WebaCGH/welcome.htm Xiaolin Wu (forestwu@mail.nih.gov) or Ulises Urzúa (uurzua@med.uchile.cl).

  17. Electrochemiluminescence assays for insulin and glutamic acid decarboxylase autoantibodies improve prediction of type 1 diabetes risk.

    Science.gov (United States)

    Miao, Dongmei; Steck, Andrea K; Zhang, Li; Guyer, K Michelle; Jiang, Ling; Armstrong, Taylor; Muller, Sarah M; Krischer, Jeffrey; Rewers, Marian; Yu, Liping

    2015-02-01

    We recently developed new electrochemiluminescence (ECL) insulin autoantibody (IAA) and glutamic acid decarboxylase 65 autoantibody (GADA) assays that discriminate high-affinity, high-risk diabetes-specific autoantibodies from low-affinity, low-risk islet autoantibodies (iAbs) detected by radioassay (RAD). Here, we report a further validation of the ECL-IAA and -GADA assays in 3,484 TrialNet study participants. The ECL assay and RAD were congruent in those with prediabetes and in subjects with multiple autoantibodies, but only 24% (P<0.0001) of single RAD-IAA-positive and 46% (P<0.0001) of single RAD-GADA-positive were confirmed by the ECL-IAA and -GADA assays, respectively. During a follow-up (mean, 2.4 years), 51% of RAD-IAA-positive and 63% of RAD-GADA-positive subjects not confirmed by ECL became iAb negative, compared with only 17% of RAD-IAA-positive (P<0.0001) and 15% of RAD-GADA-positive (P<0.0001) subjects confirmed by ECL assays. Among subjects with multiple iAbs, diabetes-free survival was significantly shorter if IAA or GADA was positive by ECL and negative by RAD than if IAA or GADA was negative by ECL and positive by RAD (P<0.019 and P<0.0001, respectively). Both positive and negative predictive values in terms of progression to type 1 diabetes mellitus were superior for ECL-IAA and ECL-GADA, compared with RADs. The prevalence of the high-risk human leukocyte antigen-DR3/4, DQB1*0302 genotype was significantly higher in subjects with RAD-IAA or RAD-GADA confirmed by ECL. In conclusion, both ECL-IAA and -GADA are more disease-specific and better able to predict the risk of progression to type 1 diabetes mellitus than the current standard RADs.

  18. Deciphering the hybridisation history leading to the Lager lineage based on the mosaic genomes of Saccharomyces bayanus strains NBRC1948 and CBS380.

    Directory of Open Access Journals (Sweden)

    Huu-Vang Nguyen

    Full Text Available Saccharomyces bayanus is a yeast species described as one of the two parents of the hybrid brewing yeast S. pastorianus. Strains CBS380(T and NBRC1948 have been retained successively as pure-line representatives of S. bayanus. In the present study, sequence analyses confirmed and upgraded our previous finding: S. bayanus type strain CBS380(T harbours a mosaic genome. The genome of strain NBRC1948 was also revealed to be mosaic. Both genomes were characterized by amplification and sequencing of different markers, including genes involved in maltotriose utilization or genes detected by array-CGH mapping. Sequence comparisons with public Saccharomyces spp. nucleotide sequences revealed that the CBS380(T and NBRC1948 genomes are composed of: a predominant non-cerevisiae genetic background belonging to S. uvarum, a second unidentified species provisionally named S. lagerae, and several introgressed S. cerevisiae fragments. The largest cerevisiae-introgressed DNA common to both genomes totals 70kb in length and is distributed in three contigs, cA, cB and cC. These vary in terms of length and presence of MAL31 or MTY1 (maltotriose-transporter gene. In NBRC1948, two additional cerevisiae-contigs, cD and cE, totaling 12kb in length, as well as several smaller cerevisiae fragments were identified. All of these contigs were partially detected in the genomes of S. pastorianus lager strains CBS1503 (S. monacensis and CBS1513 (S. carlsbergensis explaining the noticeable common ability of S. bayanus and S. pastorianus to metabolize maltotriose. NBRC1948 was shown to be inter-fertile with S. uvarum CBS7001. The cross involving these two strains produced F1 segregants resembling the strains CBS380(T or NRRLY-1551. This demonstrates that these S. bayanus strains were the offspring of a cross between S. uvarum and a strain similar to NBRC1948. Phylogenies established with selected cerevisiae and non-cerevisiae genes allowed us to decipher the complex hybridisation

  19. Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection.

    Science.gov (United States)

    Kremastinou, J; Polymerou, V; Lavranos, D; Aranda Arrufat, A; Harwood, J; Martínez Lorenzo, M J; Ng, K P; Queiros, L; Vereb, I; Cusini, M

    2016-09-01

    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. Copyright © 2016 Kremastinou et al.

  20. Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection

    Science.gov (United States)

    Kremastinou, J.; Polymerou, V.; Lavranos, D.; Aranda Arrufat, A.; Harwood, J.; Martínez Lorenzo, M. J.; Ng, K. P.; Queiros, L.; Vereb, I.

    2016-01-01

    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum. The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. PMID:27358468

  1. A duplex endpoint PCR assay for rapid detection and differentiation of Leptospira strains.

    Science.gov (United States)

    Benacer, Douadi; Zain, Siti Nursheena Mohd; Lewis, John W; Khalid, Mohd Khairul Nizam Mohd; Thong, Kwai Lin

    2017-01-01

    This study aimed to develop a duplex endpoint PCR assay for rapid detection and differentiation of Leptospira strains. Primers were designed to target the rrs (LG1/LG2) and ligB (LP1/LP2) genes to confirm the presence of the Leptospira genus and the pathogenic species, respectively. The assay showed 100% specificity against 17 Leptospira strains with a limit of detection of 23.1pg/µl of leptospiral DNA and sensitivity of 103 leptospires/ml in both spiked urine and water. Our duplex endpoint PCR assay is suitable for rapid early detection of Leptospira with high sensitivity and specificity.

  2. Reverse zymography alone does not confirm presence of a protease inhibitor.

    Science.gov (United States)

    Dutta, Sangita; Bhattacharyya, Debasish

    2013-03-01

    Reverse zymography is applied for identification and semi-quantification of protease inhibitors that are of protein in nature. However, a protein that shows band in reverse zymography against a protease used for digestion of the gel need not be an inhibitor; it might be resistant to degradation by the protease. We demonstrate that in reverse zymography, avidin, streptavidin and the leaf extract of Catharanthus roseus behave like inhibitors of proteases like papain, ficin, bromelain extracts from pineapple leaf, stem and fruit and trypsin. Still, they do not act as inhibitors of those proteases when enzyme assays were done in solution. In reverse zymography, the extract of pineapple crown leaf shows two major inhibitor bands against its own proteases. Identification of these proteins from sequences derived from MALDI TOF MS analysis indicated that they are fruit and stem bromelains. Avidin, streptavidin and bromelains are 'kinetically stable proteins' that are usually resistant to proteolysis. Thus, it is recommended that identification of an inhibitor of a protease by reverse zymography should be supported by independent assay methods for confirmation.

  3. Detection of antibodies to hepatitis B core antigen using the Abbott ARCHITECT anti-HBc assay: analysis of borderline reactive sera.

    Science.gov (United States)

    Ollier, Laurence; Laffont, Catherine; Kechkekian, Aurore; Doglio, Alain; Giordanengo, Valérie

    2008-12-01

    Routine use of the automated chemiluminescent microparticle immunoassay Abbott ARCHITECT anti-HBc for diagnosis of hepatitis B is limited in case of borderline reactive sera with low signal close to the cut-off index. In order to determine the significance of anti-HBc detection when borderline reactivity occurs using the ARCHITECT anti-HBc assay, a comparative study was designed. 3540 serum samples collected over a 2-month period in the hospital of Nice were examined for markers of HBV infection (HBsAg, anti-HBs and anti-HBc). One hundred seven samples with sufficient volume and with borderline reactivity by the ARCHITECT assay were tested by two other anti-HBc assays, a microparticle enzyme immunoassay (MEIA, AxSYM Core, Abbott Laboratories, IL, USA) and an enzyme linked fluorescent assay (ELFA, VIDAS Anti-HBc Total II, bioMérieux, Lyon, France). Only 46 samples were confirmed by the AxSYM and the VIDAS assays. Additional serological information linked to patient history showed that the remaining samples (61) were false positives (11), had low titer of anti-HBc antibodies (13), or were inconclusive (37). This comparative study highlighted the existence of a grey zone around the cut-off index. Confirmative results through a different immunoassay are needed to confirm the diagnosis of HBV on borderline reactive sera using the ARCHITECT anti-HBc assay.

  4. Performance Confirmation Plan

    International Nuclear Information System (INIS)

    Lindner, E.N.

    2000-01-01

    As described, the purpose of the Performance Confirmation Plan is to specify monitoring, testing, and analysis activities for evaluating the accuracy and adequacy of the information used to determine that performance objectives for postclosure will be met. This plan defines a number of specific performance confirmation activities and associated test concepts in support of the MGR that will be implemented to fulfill this purpose. In doing so, the plan defines an approach to identify key factors and processes, predict performance, establish tolerances and test criteria, collect data (through monitoring, testing, and experiments), analyze these data, and recommend appropriate action. The process of defining which factors to address under performance confirmation incorporates input from several areas. In all cases, key performance confirmation factors are those factors which are: (1) important to safety, (2) measurable and predictable, and (3) relevant to the program (i.e., a factor that is affected by construction, emplacement, or is a time-dependent variable). For the present version of the plan, performance confirmation factors important to safety are identified using the principal factors from the RSS (CRWMS M and O 2000a) (which is derived from TSPA analyses) together with other available performance assessment analyses. With this basis, key performance confirmation factors have been identified, and test concepts and test descriptions have been developed in the plan. Other activities are also incorporated into the performance confirmation program outside of these key factors. Additional activities and tests have been incorporated when they are prescribed by requirements and regulations or are necessary to address data needs and model validation requirements relevant to postclosure safety. These other activities have been included with identified factors to construct the overall performance confirmation program

  5. Performance Confirmation Plan

    International Nuclear Information System (INIS)

    Lindner, E.N.

    2000-01-01

    As described, the purpose of the Performance Confirmation Plan is to specify monitoring, testing, and analysis activities for evaluating the accuracy and adequacy of the information used to determine that performance objectives for postclosure will be met. This plan defines a number of specific performance confirmation activities and associated test concepts in support of the MGR that will be implemented to fulfill this purpose. In doing so, the plan defines an approach to identify key factors and processes, predict performance, establish tolerances and test criteria, collect data (through monitoring, testing, and experiments), analyze these data, and recommend appropriate action. The process of defining which factors to address under performance confirmation incorporates input from several areas. In all cases, key performance confirmation factors are those factors which are: (1) important to safety, (2) measurable and predictable, and (3) relevant to the program (i.e., a factor that i s affected by construction, emplacement, or is a time-dependent variable). For the present version of the plan, performance confirmation factors important to safety are identified using the principal factors from the RSS (CRWMS M and O 2000a) (which is derived from TSPA analyses) together with other available performance assessment analyses. With this basis, key performance confirmation factors have been identified, and test concepts and test descriptions have been developed in the plan. Other activities are also incorporated into the performance confirmation program outside of these key factors. Additional activities and tests have been incorporated when they are prescribed by requirements and regulations or are necessary to address data needs and model validation requirements relevant to postclosure safety. These other activities have been included with identified factors to construct the overall performance confirmation program

  6. Field experience with a mobile tomographic nondestructive assay system

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Betts, S.E.; Taggart, D.P.; Estep, R.J.; Nicholas, N.J.; Lucas, M.C.; Harlan, R.A.

    1995-01-01

    A mobile tomographic gamma-ray scanner (TGS) developed by Los Alamos National Laboratory was recently demonstrated at the Rocky Flats Environmental Technology Site and is currently in use at Los Alamos waste storage areas. The scanner was developed to assay radionuclides in low-level, transuranic, and mixed waste in containers ranging in size from 2 ft 3 boxes to 83-gallon overpacks. The tomographic imaging capability provides a complete correction for source distribution and matrix attenuation effects, enabling accurate assays of Pu-239 and other gamma-ray emitting isotopes. In addition, the system can reliably detect self-absorbing material such as plutonium metal shot, and can correct for bias caused by self-absorption. The system can be quickly configured to execute far-field scans, segmented gamma-ray scans, and a host of intermediate scanning protocols, enabling higher throughput (up to 20 drums per 8-hour shift). In this paper, we will report on the results of field trials of the mobile system at Rocky Flats and Los Alamos. Assay accuracy is confirmed for cases in which TGS assays can be compared with assays (e.g. with calorimetry) of individual packages within the drums. The mobile tomographic technology is expected to considerably reduce characterization costs at DOE production and environmental technology sites

  7. Use of immunoblotting assay improves the sensitivity of paracoccidioidomycosis diagnosis

    Directory of Open Access Journals (Sweden)

    D. F. Silva

    2008-01-01

    Full Text Available The purpose of this work was to evaluate two serological assays: double immunodiffusion (DI and immunoblotting (IB in immunodiagnosis of paracoccidioidomycosis (PCM. We evaluated by IB assay 23 sera samples from patients with clinical confirmation of PCM, all of them with negative DI results against culture filtrate from Paracoccidioides brasiliensis isolate 113. For IB, as well as for comparative DI assay, we employed soluble components of the cell wall outer surface (SCCWOS from P. brasiliensis isolate 113 cultivated at 36°C in Fava-Neto's agar medium for 5 and 10 days. Among the 20 sera samples analyzed by DI, 13 (65% were negative and 7 (35% were positive against SCCWOS obtained on the 5th and 10th days. By IB assay, 95.4% and 100% of sera reacted against gp43 and gp70 present in SCCWOS from the 5th day and 95.6% recognized these fractions when evaluated against SCCWOS from the 10th day. Our results demonstrated that the use of an immunoenzymatic assay significantly improves the sensitivity of PCM immunodiagnosis and also suggests that at least two serological tests for antibody detection should be adopted in cases of questionable diagnosis.

  8. A molecular-beacon-based asymmetric PCR assay for easy visualization of amplicons in the diagnosis of trichomoniasis.

    Science.gov (United States)

    Sonkar, Subash C; Sachdev, Divya; Mishra, Prashant K; Kumar, Anita; Mittal, Pratima; Saluja, Daman

    2016-12-15

    The currently available nucleic acid amplification tests (NAATs) for trichomoniasis are accurate, quick and confirmative with superior sensitivity than traditional culture-based microbiology assays. However, these assays are associated with problems of carry over contamination, false positive results, requirement of technical expertise for performance and detection of end product. Hence, a diagnostic assay with easy visualization of the amplified product will be profitable. An in-house, rapid, sensitive, specific molecular-beacon-based PCR assay, using primers against pfoB gene of Trichomonas vaginalis, was developed and evaluated using dry ectocervical swabs (n=392) from symptomatic females with vaginal discharge. Total DNA was isolated and used as template for the PCR assays. The performance and reproducibility of PCR assay was evaluated by composite reference standard (CRS). For easy visualization of the amplified product, molecular-beacon was designed and amplicons were visualized directly using fluorescent handheld dark reader or by Micro-Plate Reader. Molecular-beacons are single-stranded hairpin shaped nucleic acid probes composed of a stem, with fluorophore/quencher pair and a loop region complementary to the desired DNA. The beacon-based PCR assay designed in the present study is highly specific as confirmed by competition experiments and extremely sensitive with detection limit of 20fg of genomic DNA (3-4 pathogens). The minimum infrastructure requirement and ease to perform the assay makes this method highly useful for resource poor countries for better disease management. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Repository performance confirmation

    International Nuclear Information System (INIS)

    Hansen, Francis D.

    2011-01-01

    Repository performance confirmation links the technical bases of repository science and societal acceptance. This paper explores the myriad aspects of what has been labeled performance confirmation in U.S. programs, which involves monitoring as a collection of distinct activities combining technical and social significance in radioactive waste management. This paper is divided into four parts: (1) A distinction is drawn between performance confirmation monitoring and other testing and monitoring objectives; (2) A case study illustrates confirmation activities integrated within a long-term testing and monitoring strategy for Yucca Mountain; (3) A case study reviews compliance monitoring developed and implemented for the Waste Isolation Pilot Plant; and (4) An approach for developing, evaluating and implementing the next generation of performance confirmation monitoring is presented. International interest in repository monitoring is exhibited by the European Commission Seventh Framework Programme 'Monitoring Developments for Safe Repository Operation and Staged Closure' (MoDeRn) Project. The MoDeRn partners are considering the role of monitoring in a phased approach to the geological disposal of radioactive waste. As repository plans advance in different countries, the need to consider monitoring strategies within a controlled framework has become more apparent. The MoDeRn project pulls together technical and societal experts to assimilate a common understanding of a process that could be followed to develop a monitoring program. A fundamental consideration is the differentiation of confirmation monitoring from the many other testing and monitoring activities. Recently, the license application for Yucca Mountain provided a case study including a technical process for meeting regulatory requirements to confirm repository performance as well as considerations related to the preservation of retrievability. The performance confirmation plan developed as part of the

  10. The evaluation of a user-friendly lateral flow assay for the serodiagnosis of human brucellosis in Kazakhstan

    NARCIS (Netherlands)

    Mizanbayeva, Sulushash; Smits, Henk L.; Zhalilova, Katya; Abdoel, Theresia H.; Kozakov, Stanislaw; Ospanov, Kenes S.; Elzer, Philip H.; Douglas, James T.

    2009-01-01

    Serum samples from all patients with culture-confirmed brucellosis including those with chronic disease from Kazakhstan tested positive in the serum agglutination test for titers > or = 1:25 and reacted in the Brucella immunoglobulin M/immunoglobulin G lateral flow assay (LFA) confirming the high

  11. Loop-mediated isothermal amplification (LAMP) assay for the diagnosis of fasciolosis in sheep and its application under field conditions.

    Science.gov (United States)

    Martínez-Valladares, María; Rojo-Vázquez, Francisco Antonio

    2016-02-05

    Loop-mediated isothermal amplification (LAMP) is a very specific, efficient, and rapid gene amplification procedure in which the reaction can run at a constant temperature. In the current study we have developed a LAMP assay to improve the diagnosis of Fasciola spp. in the faeces of sheep. After the optimisation of the LAMP assay we have shown similar results between this technique and the standard PCR using the outer primers of the LAMP reaction. In both cases the limit of detection was 10 pg; also, the diagnosis of fasciolosis was confirmed during the first week post-infection in experimental infected sheep by both techniques. In eight naturally infected sheep, the infection with F. hepatica was confirmed in all animals before a treatment with triclabendazole and on day 30 post treatment in two sheep using the LAMP assay; however, when we carried out the standard PCR with the outer primers, the results before treatment were the same but on day 30 post-treatment the infection was only confirmed in one out of the two sheep. On the other hand, the standard PCR took around 3 h to obtain a result, comparing with 1 h and 10 min for the LAMP assay. The LAMP assay described here could be a good alternative to conventional diagnostic methods to detect F. hepatica in faeces since it solves the drawbacks of the standard PCR.

  12. O-5S quantitative real-time PCR: a new diagnostic tool for laboratory confirmation of human onchocerciasis.

    Science.gov (United States)

    Mekonnen, Solomon A; Beissner, Marcus; Saar, Malkin; Ali, Solomon; Zeynudin, Ahmed; Tesfaye, Kassahun; Adbaru, Mulatu G; Battke, Florian; Poppert, Sven; Hoelscher, Michael; Löscher, Thomas; Bretzel, Gisela; Herbinger, Karl-Heinz

    2017-10-02

    Onchocerciasis is a parasitic disease caused by the filarial nematode Onchocerca volvulus. In endemic areas, the diagnosis is commonly confirmed by microscopic examination of skin snip samples, though this technique is considered to have low sensitivity. The available melting-curve based quantitative real-time PCR (qPCR) using degenerated primers targeting the O-150 repeat of O. volvulus was considered insufficient for confirming the individual diagnosis, especially in elimination studies. This study aimed to improve detection of O. volvulus DNA in clinical samples through the development of a highly sensitive qPCR assay. A novel hydrolysis probe based qPCR assay was designed targeting the specific sequence of the O. volvulus O-5S rRNA gene. A total of 200 clinically suspected onchocerciasis cases were included from Goma district in South-west Ethiopia, from October 2012 through May 2013. Skin snip samples were collected and subjected to microscopy, O-150 qPCR, and the novel O-5S qPCR. Among the 200 individuals, 133 patients tested positive (positivity rate of 66.5%) and 67 negative by O-5S qPCR, 74 tested positive by microscopy (37.0%) and 78 tested positive by O-150 qPCR (39.0%). Among the 133 O-5S qPCR positive individuals, microscopy and O-150 qPCR detected 55.6 and 59.4% patients, respectively, implying a higher sensitivity of O-5S qPCR than microscopy and O-150 qPCR. None of the 67 individuals who tested negative by O-5S qPCR tested positive by microscopy or O-150 qPCR, implying 100% specificity of the newly designed O-5S qPCR assay. The novel O-5S qPCR assay is more sensitive than both microscopic examination and the existing O-150 qPCR for the detection of O. volvulus from skin snip samples. The newly designed assay is an important step towards appropriate individual diagnosis and control of onchocerciasis.

  13. An automated immunoradiometric assay of thyrotrophin (TSH) in dried blood filter paper spots

    International Nuclear Information System (INIS)

    John, R.; Woodhead, J.S.

    1982-01-01

    An immunoradiometric two-site assay for thyrotrophin (TSH) in dried blood filter paper spots is described. The assay is automated by means of the Kemtek 3000 automated immunoassay system. The technique uses a 6.0 mm disc punched from the dried blood samples collected as part of the screening programme for phenylketonuria. The method is sensitive and precise, and results correlate well with those obtained in TSH assays of serum samples. The procedure is rapid, results being available within 24 h of receipt of samples. Of 25204 specimens so far screened by this assay, 99.9% have TSH levels less than 15 mU/l. One false positive result has been obtained and six confirmed cases of neonatal hypothyroidism detected, giving a prevalence of 1 in 4200. (Auth.)

  14. Kyasanur Forest Disease Prevalence in Western Ghats Proven and Confirmed by Recent Outbreak in Maharashtra, India, 2016.

    Science.gov (United States)

    Gurav, Yogesh K; Yadav, Pragya D; Gokhale, Mangesh D; Chiplunkar, Tushar R; Vishwanathan, Rajlakshmi; Patil, Deepak Y; Jain, Rajlaxmi; Shete, Anita M; Patil, Savita L; Sarang, G D; Sapkal, Gajanan N; Andhare, M D; Sale, Y R; Awate, Pradeep S; Mourya, Devendra T

    2018-03-01

    Kyasanur forest disease (KFD) outbreak was confirmed in Dodamarg Taluka, Sindhudurga district (Maharashtra) in India during the year 2016. The rise in suspected KFD cases was reported in January 2016, peaked during March, and then declined gradually from April 2016. The outbreak was thoroughly investigated considering different socio-clinical parameters. Total, 488 suspected KFD cases were investigated using KFD specific real-time RT-PCR and anti-KFDV IgM enzyme-linked immunosorbent assay (ELISA). Sero-epidemiological survey was carried out in the affected area using anti-KFDV IgG ELISA. Among suspected KFD cases, high age-specific attack rate (105.1 per 1000 persons) was observed in adults (aged 40-59 years). Out of 488 suspected KFD cases, 130 were laboratory confirmed. Of these, 54 cases were KFDV real-time RT-PCR positive, 66 cases were anti-KFDV IgM ELISA positive and 10 cases were positive by both the assays. Case fatality ratio among laboratory-confirmed KFD cases were 2.3% (3/130). Majority of laboratory-confirmed KFD cases (93.1%) had visited Western Ghats forest in Dodamarg for activities like working in cashew nut farms (79.8%), cashew nut fruit collection (76.6%), collection of firewood (68.5%) and dry leaves/grass (40.3%), etc., before the start of symptoms. Common clinical features included fever (100%), headache (93.1%), weakness (84.6%), and myalgia (83.1%). Hemorrhagic manifestations were observed in nearly one-third of the laboratory-confirmed KFD cases (28.5%). A seroprevalence of (9.7%, 72/745) was recorded in KFD-affected area and two neighboring villages (9.1%, 15/165). Serosurvey conducted in Ker village showed clinical to subclinical ratio of 6:1 in KFD-affected areas. This study confirms the outbreak of KFD Sindhudurg district with 130 cases. Detection of anti-KFDV IgG antibodies among the healthy population in KFD-affected area during the KFD outbreak suggested the past exposure of KFD infection. This outbreak investigation has helped

  15. Immunoassay screening of lysergic acid diethylamide (LSD) and its confirmation by HPLC and fluorescence detection following LSD ImmunElute extraction.

    Science.gov (United States)

    Grobosch, T; Lemm-Ahlers, U

    2002-04-01

    In all, 3872 urine specimens were screened for lysergic acid diethylamide (LSD) using the CEDIA DAU LSD assay. Forty-eight samples, mainly from psychiatric patients or drug abusers, were found to be LSD positive, but only 13 (27%) of these could be confirmed by high-performance liquid chromatography with fluorescence detection (HPLC-FLD) following immunoaffinity extraction (IAE). Additional analysis for LSD using the DPC Coat-a-Count RIA was performed to compare the two immunoassay screening methods. Complete agreement between the DPC RIA assay and HPLC-FLD results was observed at concentrations below a cutoff concentration of 500 pg/mL. Samples that were LSD positive in the CEDIA DAU assay but not confirmed by HPLC-FLD were also investigated for interfering compounds using REMEDI HS drug-profiling system. REMEDI HS analysis identified 15 compounds (parent drugs and metabolites) that are believed to cross-react in the CEDIA DAU LSD assay: ambroxol, prilocaine, pipamperone, diphenhydramine, metoclopramide, amitriptyline, doxepine, atracurium, bupivacaine, doxylamine, lidocaine, mepivacaine, promethazine, ranitidine, and tramadole. The IAE/HPLC-FLD combination is rapid, easy to perform and reliable. It can reduce costs when standard, rather than more advanced, HPLC equipment is used, especially for labs that perform analyses for LSD infrequently. The chromatographic analysis of LSD, nor-LSD, and iso-LSD is not influenced by any of the tested cross-reacting compounds even at a concentration of 100 ng/mL.

  16. Specific and straightforward molecular investigation of β-thalassemia mutations in the Malaysian Malays and Chinese using direct TaqMan genotyping assays.

    Science.gov (United States)

    Kho, S L; Chua, K H; George, E; Tan, J A M A

    2013-07-15

    Beta-thalassemia is a life-threatening inherited blood disorder. Rapid characterization of β-globin gene mutations is necessary because of the high frequency of Malaysian β-thalassemia carriers. A combination real-time polymerase chain reaction genotyping assay using TaqMan probes was developed to confirm β-globin gene mutations. In this study, primers and probes were designed to specifically identify 8 common β-thalassemia mutations in the Malaysian Malay and Chinese ethnic groups using the Primer Express software. "Blind tests" using DNA samples from healthy individuals and β-thalassemia patients with different genotypes were performed to determine the specificity and sensitivity of this newly designed assay. Our results showed 100% sensitivity and specificity for this novel assay. In conclusion, the TaqMan genotyping assay is a straightforward assay that allows detection of β-globin gene mutations in less than 40 min. The simplicity and reproducibility of the TaqMan genotyping assay permit its use in laboratories as a rapid and cost-effective diagnostic tool for confirmation of common β-thalassemia mutations in Malaysia.

  17. Molecular identification of birds: performance of distance-based DNA barcoding in three genes to delimit parapatric species.

    Directory of Open Access Journals (Sweden)

    Mansour Aliabadian

    Full Text Available DNA barcoding based on the mitochondrial cytochrome oxidase subunit I gene (cox1 or COI has been successful in species identification across a wide array of taxa but in some cases failed to delimit the species boundaries of closely allied allopatric species or of hybridising sister species.In this study we extend the sample size of prior studies in birds for cox1 (2776 sequences, 756 species and target especially species that are known to occur parapatrically, and/or are known to hybridise, on a Holarctic scale. In order to obtain a larger set of taxa (altogether 2719 species, we include also DNA sequences of two other mitochondrial genes: cytochrome b (cob (4614 sequences, 2087 species and 16S (708 sequences, 498 species. Our results confirm the existence of a wide gap between intra- and interspecies divergences for both cox1 and cob, and indicate that distance-based DNA barcoding provides sufficient information to identify and delineate bird species in 98% of all possible pairwise comparisons. This DNA barcoding gap was not statistically influenced by the number of individuals sequenced per species. However, most of the hybridising parapatric species pairs have average divergences intermediate between intraspecific and interspecific distances for both cox1 and cob.DNA barcoding, if used as a tool for species discovery, would thus fail to identify hybridising parapatric species pairs. However, most of them can probably still assigned to known species by character-based approaches, although development of complementary nuclear markers will be necessary to account for mitochondrial introgression in hybridising species.

  18. Demonstrating Interactions of Transcription Factors with DNA by Electrophoretic Mobility Shift Assay.

    Science.gov (United States)

    Yousaf, Nasim; Gould, David

    2017-01-01

    Confirming the binding of a transcription factor with a particular DNA sequence may be important in characterizing interactions with a synthetic promoter. Electrophoretic mobility shift assay is a powerful approach to demonstrate the specific DNA sequence that is bound by a transcription factor and also to confirm the specific transcription factor involved in the interaction. In this chapter we describe a method we have successfully used to demonstrate interactions of endogenous transcription factors with sequences derived from endogenous and synthetic promoters.

  19. Primary ovary choriocarcinoma: individual DNA polymorphic analysis as a strategy to confirm diagnosis and treatment

    Directory of Open Access Journals (Sweden)

    Fernando Nalesso

    2013-04-01

    Full Text Available Primary choriocarcinoma of the ovary is rare. Furthermore, this tumor can arise from gestational tissue or pure germ cells of the ovary, with the latter resulting in non-gestational choriocarcinoma. While the clinical characteristics and histology of both tumor types are identical, differentiation of these tumors is necessary for effective treatment. One strategy for the differentiation of these tumors types is to assay for the presence of paternal DNA. Accordingly, in the present case, a patient with primary choriocarcinoma of the ovary with a non-gestational origin was confirmed by DNA analysis. The patient subsequently exhibited an excellent response to chemotherapy, and following surgery, achieved complete remission. A pathological analysis of surgical specimens further confirmed the absence of tumor.

  20. Development of a novel in vitro assay for the evaluation of integron DNA integrase activity

    Directory of Open Access Journals (Sweden)

    Fatemeh Tohidi

    2016-05-01

    Full Text Available Integrons play an important role in multidrug resistance. The integron platform codes for integrase (intI that is required for gene cassette integration through site-specific recombination. The recombination crossover occurs between the G and TT nucleotides in non-palindromic attI and palindromic attC sites. The aim of this study was to establish an efficient in vitro assay for integrase purification and activity detection. To this end, the intI gene was cloned into the pET-22b plasmid. Then, the resulting recombinant plasmid was transformed into Escherichia coli Origami™ strain. The recombinant protein expression was confirmed by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE and western blot assays. The recombinant intI protein was purified by nickel–nitrilotriacetic acid (Ni–NTA affinity chromatography, and its activity was measured by a newly introduced assay. Briefly, specific primers for each side of attI and attC were used, thereby, a polymerase chain reaction would be performed, if a fused plasmid containing both attI and attC sites was created upon recombination. SDS-PAGE and western blotting confirmed the presence of a 38-kDa recombinant protein. Optimum conditions were established for the measurement of the integrase activity and a new model assay was conducted to analyse the recombination activity in vitro. Although the electrophoretic mobility shift assay is an efficient and reliable method, the newly introduced assay provided new or enhanced capability to determine the integrase activity, suggesting that there is no need for expensive and advanced equipment.

  1. Development of a highly sensitive and specific enzyme-linked immunosorbent assay (ELISA) for the detection of phenylethanolamine A in tissue and feed samples and confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS).

    Science.gov (United States)

    Cao, Biyun; He, Guangzhao; Yang, Hong; Chang, Huafang; Li, Shuqun; Deng, Anping

    2013-10-15

    Phenylethanolamine A (PA) is a new emerged β-adrenergic agonist illegally used as feed additives for growth promotion. In this study, a highly sensitive and specific indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of PA in tissue and feed samples was developed and confirmed by liquid chromatography tandem mass spectrometry (LC-MS/MS). By reduction of nitryl group to amino group, the PA derivative was synthesized and coupled to carrier proteins with diazobenzidine method. The antisera obtained from four immunized rabbits were characterized in terms of sensitivity and specificity. All antisera displayed high sensitivity with IC50 values lower than 0.48 ng mL(-1). The most sensitive ELISA was established with IC50 and limit of detection (LOD) values of 0.049 ng mL(-1) and 0.003 ng mL(-1), respectively. The cross-reactivity (CR) values of the antisera with three frequently used β-adrenergic agonists (clenbuterol, salbutamol and ractopamine) were lesser than 0.39%; there was no CR of the antisera with other six compounds including two structurally related substances (isoproterenol, phenylephrine). To investigate the accuracy and precision of the assay, swine kidney, liver, meat and feed samples were fortified with PA at different content and analyzed by ELISA. Acceptable recovery rates of 92.2-113.7% and intra-assay coefficients of variation of 3.8-10.9% (n=3) were achieved. Seven spiked samples were simultaneously analyzed by ELISA and LC-MS/MS. There was a high correlation coefficient of 0.9956 (n=7) between the two methods. The proposed ELISA proven to be a feasible quantitative/screening method for PA analysis in tissue and feed samples with the properties of high sensitivity and specificity, high sample throughput and low expensive. © 2013 Elsevier B.V. All rights reserved.

  2. Rapid and specific identification of Brucella abortus using the loop-mediated isothermal amplification (LAMP) assay.

    Science.gov (United States)

    Kang, Sung-Il; Her, Moon; Kim, Ji-Yeon; Lee, Jin Ju; Lee, Kichan; Sung, So-Ra; Jung, Suk Chan

    2015-06-01

    A rapid and accurate diagnosis of brucellosis is required to reduce and prevent the spread of disease among animals and the risk of transfer to humans. In this study, a Brucella abortus-specific (Ba) LAMP assay was developed, that had six primers designed from the BruAb2_0168 region of chromosome I. The specificity of this LAMP assay was confirmed with Brucella reference strains, B. abortus vaccine strains, B. abortus isolates and phylogenetically or serologically related strains. The detection limit of target DNA was up to 20 fg/μl within 60 min. The sensitivity of the new LAMP assay was equal to or slightly higher than other PCR based assays. Moreover, this Ba-LAMP assay could specifically amplify all B. abortus biovars compared to previous PCR assays. To our knowledge, this is the first report of specific detection of B. abortus using a LAMP assay. The Ba-LAMP assay can offer a rapid, sensitive and accurate diagnosis of bovine brucellosis in the field. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Evaluation of Chicken IgY Generated Against Canine Parvovirus Viral-Like Particles and Development of Enzyme-Linked Immunosorbent Assay and Immunochromatographic Assay for Canine Parvovirus Detection.

    Science.gov (United States)

    He, Jinxin; Wang, Yuan; Sun, Shiqi; Zhang, Xiaoying

    2015-11-01

    Immunoglobulin Y (IgY) antibodies were generated against canine parvovirus virus-like particles (CPV-VLPs) antigen using chickens. Anti-CPV-VLPs-IgY was extracted from hen egg yolk and used for developing enzyme-linked immunosorbent assay (ELISA) and immunochromatographic assay (ICA) for the detection of CPV in dog feces. The cutoff negative values for anti-CPV-VLPs-IgY were determined using negative fecal samples (already confirmed by polymerase chain reaction [PCR]). In both ELISA and ICA, there was no cross-reaction with other diarrheal pathogens. Thirty-four fecal samples were collected from dogs with diarrhea, of which 26.47% were confirmed as CPV-positive samples by PCR, while 29.41% and 32.35% of the samples were found to be positive by ELISA and ICA, respectively. The developed ELISA and ICA exhibited 97.06% and 94.12% conformity with PCR. Higher sensitivity and specificity were observed for IgY-based ELISA and ICA. Thus, they could be suitable for routine use in the diagnosis of CPV in dogs.

  4. Nested PCR detection of Plasmodium malariae from microscopy confirmed P. falciparum samples in endemic area of NE India.

    Science.gov (United States)

    Dhiman, Sunil; Goswami, Diganta; Kumar, Dinesh; Rabha, Bipul; Sharma, Dhirendra Kumar; Bhola, Rakesh Kumar; Baruah, Indra; Veer, Vijay

    2013-11-01

    The present study evaluates the performance of OptiMAL-IT test and nested PCR assay in detection of malaria parasites. A total of 76 randomly selected blood samples collected from two malaria endemic areas were tested for malaria parasites using microscopy and OptiMAL-IT test in the field. PCR assays were performed in the laboratory using DNA extracted from blood spots of the same samples collected on the FTA classic cards. Of the total of 61 field confirmed malaria positive samples, only 58 (95%) were detected positive using microscopy in the laboratory. Sensitivity, specificity, positive predictive value, negative predictive value and false discovery rate of OptiMal-IT in comparison to the microscopy were 93%, 83%, 95%, 79% and 5%, respectively. On the other hand, the sensitivity and specificity of PCR assay were 97% and 100%, respectively, whereas positive predictive value, negative predictive value and false discovery rate were 100%, 90% and 0%, respectively. The overall performance of OptiMal-IT and PCR assays for malaria diagnosis was 76% and 97%, respectively. PCR assay enabled the identification of infection with Plasmodium malariae Laveran, 1881 in four samples misidentified by microscopy and Plasmodium-specific antigen (PAN) identified by the OptiMAL-IT test. In addition to the standard methods, such PCR assay could be useful to obtain the real incidence of each malaria parasite species for epidemiological perspectives.

  5. Immunochromatographic strip assay for the rapid and sensitive detection of Salmonella Typhimurium in artificially contaminated tomato samples.

    Science.gov (United States)

    Shukla, Shruti; Leem, Hyerim; Lee, Jong-Suk; Kim, Myunghee

    2014-06-01

    This study was designed to confirm the applicability of a liposome-based immunochromatographic assay for the rapid detection of Salmonella enterica subsp. enterica serovar Typhimurium (Salmonella Typhimurium) in artificially contaminated tomato samples. To determine the detection limit and pre-enrichment incubation time (10, 12, and 18 h pre-enrichment in 1% buffered peptone water), the tests were performed with different cell numbers of Salmonella Typhimurium (3 × 10(0), 3 × 10(1), 3 × 10(2), and 3 × 10(3) CFU·mL(-1)) inoculated into 25 g of crushed tomato samples. The assay was able to detect as few as 30 Salmonella Typhimurium cells per 25 g of tomato samples (1.2 cells·g(-1)) after 12 h pre-enrichment incubation. Moreover, when the developed assay was compared with traditional morphological and biochemical culture-based methods as well as colloidal gold nanoparticle-based commercial test strips, the developed assay yielded positive results for the detection of Salmonella Typhimurium within a shorter period time. These findings confirm that the developed assay may have practical application for the sensitive detection of Salmonella Typhimurium in various food samples, including raw vegetables, with a relatively low detection limit and shorter analysis time.

  6. [Comparative genomic hybridisation as a first option in genetic diagnosis: 1,000 cases and a cost-benefit analysis].

    Science.gov (United States)

    Castells-Sarret, Neus; Cueto-González, Anna M; Borregan, Mar; López-Grondona, Fermina; Miró, Rosa; Tizzano, Eduardo; Plaja, Alberto

    2017-09-25

    Conventional cytogenetics diagnoses 3-5% of patients with unexplained developmental delay/intellectual disability and/or multiple congenital anomalies. The Multiplex Ligation-dependent Probe Amplification increases diagnostic rates from between 2.4 to 5.8%. Currently the comparative genomic hybridisation array or aCGH is the highest performing diagnostic tool in patients with developmental delay/intellectual disability, congenital anomalies and autism spectrum disorders. Our aim is to evaluate the efficiency of the use of aCGH as first-line test in these and other indications (epilepsy, short stature). A total of 1000 patients referred due to one or more of the abovementioned disorders were analysed by aCGH. Pathogenic genomic imbalances were detected in 14% of the cases, with a variable distribution of diagnosis according to the phenotypes: 18.9% of patients with developmental delay/intellectual disability; 13.7% of multiple congenital anomalies, 9.76% of psychiatric pathologies, 7.02% of patients with epilepsy, and 13.3% of patients with short stature. Within the multiple congenital anomalies, central nervous system abnormalities and congenital heart diseases accounted for 14.9% and 10.6% of diagnoses, respectively. Among the psychiatric disorders, patients with autism spectrum disorders accounted for 8.9% of the diagnoses. Our results demonstrate the effectiveness and efficiency of the use of aCGH as the first line test in genetic diagnosis of patients suspected of genomic imbalances, supporting its inclusion within the National Health System. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  7. Bioelectrochemical biosensor for water toxicity detection: generation of dual signals for electrochemical assay confirmation.

    Science.gov (United States)

    Yang, Yuan; Wang, Yan-Zhai; Fang, Zhen; Yu, Yang-Yang; Yong, Yang-Chun

    2018-02-01

    Toxicity assessment of water is of great important to the safety of human health and to social security because of more and more toxic compounds that are spilled into the aquatic environment. Therefore, the development of fast and reliable toxicity assessment methods is of great interest and attracts much attention. In this study, by using the electrochemical activity of Shewanella oneidensis MR-1 cells as the toxicity indicator, 3,5-dichlorophenol (DCP) as the model toxic compound, a new biosensor for water toxicity assessment was developed. Strikingly, the presence of DCP in the water significantly inhibited the maximum current output of the S. oneidensis MR-1 in a three-electrode system and also retarded the current evolution by the cells. Under the optimized conditions, the maximum current output of the biosensor was proportional to the concentration of DCP up to 30 mg/L. The half maximal inhibitory concentration of DCP determined by this biosensor is about 14.5 mg/L. Furthermore, simultaneous monitoring of the retarded time (Δt) for current generation allowed the identification of another biosensor signal in response to DCP which could be employed to verify the electrochemical result by dual confirmation. Thus, the present study has provided a reliable and promising approach for water quality assessment and risk warning of water toxicity.

  8. A multiplex, internally controlled real-time PCR assay for detection of toxigenic Clostridium difficile and identification of hypervirulent strain 027/ST-1

    DEFF Research Database (Denmark)

    Hoegh, A M; Nielsen, J B; Lester, A

    2012-01-01

    The purpose of this study was to validate a multiplex real-time PCR assay capable of detecting toxigenic Clostridium difficile and simultaneously identifying C. difficile ribotype 027/ST-1 by targeting the toxin genes tcdA, tcdB and cdtA in one reaction and in a separate reaction identifying the Δ...... to confirm the correct identification of the Δ117 deletion in tcdC and C. difficile ribotype 027/ST-1, respectively. The PCR assay displayed a sensitivity, specificity, PPV and NPV of 99.0%, 97.4%, 87.4% and 99.8%, respectively, compared to toxigenic culture on 665 samples evaluable both by PCR and culture....... Sequencing of tcdC, ribotyping and MLST of cultured isolates validated the genotyping assay and confirmed the ability of the assay to correctly identify C. difficile ribotype 027/ST-1 in our current epidemiological setting. We describe the use of a combination of two separate PCR assays for sensitive...

  9. Target-Specific Assay for Rapid and Quantitative Detection of Mycobacterium chimaera DNA.

    Science.gov (United States)

    Zozaya-Valdés, Enrique; Porter, Jessica L; Coventry, John; Fyfe, Janet A M; Carter, Glen P; Gonçalves da Silva, Anders; Schultz, Mark B; Seemann, Torsten; Johnson, Paul D R; Stewardson, Andrew J; Bastian, Ivan; Roberts, Sally A; Howden, Benjamin P; Williamson, Deborah A; Stinear, Timothy P

    2017-06-01

    Mycobacterium chimaera is an opportunistic environmental mycobacterium belonging to the Mycobacterium avium - M. intracellulare complex. Although most commonly associated with pulmonary disease, there has been growing awareness of invasive M. chimaera infections following cardiac surgery. Investigations suggest worldwide spread of a specific M. chimaera clone, associated with contaminated hospital heater-cooler units used during the surgery. Given the global dissemination of this clone, its potential to cause invasive disease, and the laboriousness of current culture-based diagnostic methods, there is a pressing need to develop rapid and accurate diagnostic assays specific for M. chimaera Here, we assessed 354 mycobacterial genome sequences and confirmed that M. chimaera is a phylogenetically coherent group. In silico comparisons indicated six DNA regions present only in M. chimaera We targeted one of these regions and developed a TaqMan quantitative PCR (qPCR) assay for M. chimaera with a detection limit of 100 CFU/ml in whole blood spiked with bacteria. In vitro screening against DNA extracted from 40 other mycobacterial species and 22 bacterial species from 21 diverse genera confirmed the in silico -predicted specificity for M. chimaera Screening 33 water samples from heater-cooler units with this assay highlighted the increased sensitivity of PCR compared to culture, with 15 of 23 culture-negative samples positive by M. chimaera qPCR. We have thus developed a robust molecular assay that can be readily and rapidly deployed to screen clinical and environmental specimens for M. chimaera . Copyright © 2017 American Society for Microbiology.

  10. Recombinase polymerase and enzyme-linked immunosorbent assay as a DNA amplification-detection strategy for food analysis

    Energy Technology Data Exchange (ETDEWEB)

    Santiago-Felipe, S.; Tortajada-Genaro, L.A.; Puchades, R.; Maquieira, A., E-mail: amaquieira@qim.upv.es

    2014-02-06

    Graphical abstract: -- Highlights: •Recombinase polymerase amplification is a powerful DNA method operating at 40 °C. •The combination RPA–ELISA gives excellent performances for high-throughput analysis. •Screening of food safety threats has been done using standard laboratory equipment. •Allergens, GMOs, bacteria, and fungi have been successfully determined. -- Abstract: Polymerase chain reaction in conjunction with enzyme-linked immunosorbent assay (PCR–ELISA) is a well-established technique that provides a suitable rapid, sensitive, and selective method for a broad range of applications. However, the need for precise rapid temperature cycling of PCR is an important drawback that can be overcome by employing isothermal amplification reactions such as recombinase polymerase amplification (RPA). The RPA–ELISA combination is proposed for amplification at a low, constant temperature (40 °C) in a short time (40 min), for the hybridisation of labelled products to specific 5′-biotinylated probes/streptavidin in coated microtiter plates at room temperature, and for detection by colorimetric immunoassay. RPA–ELISA was applied to screen common safety threats in foodstuffs, such as allergens (hazelnut, peanut, soybean, tomato, and maize), genetically modified organisms (P35S and TNOS), pathogenic bacteria (Salmonella sp. and Cronobacter sp.), and fungi (Fusarium sp.). Satisfactory sensitivity and reproducibility results were achieved for all the targets. The RPA–ELISA technique does away with thermocycling and provides a suitable sensitive, specific, and cost-effective method for routine applications, and proves particularly useful for resource-limited settings.

  11. Recombinase polymerase and enzyme-linked immunosorbent assay as a DNA amplification-detection strategy for food analysis

    International Nuclear Information System (INIS)

    Santiago-Felipe, S.; Tortajada-Genaro, L.A.; Puchades, R.; Maquieira, A.

    2014-01-01

    Graphical abstract: -- Highlights: •Recombinase polymerase amplification is a powerful DNA method operating at 40 °C. •The combination RPA–ELISA gives excellent performances for high-throughput analysis. •Screening of food safety threats has been done using standard laboratory equipment. •Allergens, GMOs, bacteria, and fungi have been successfully determined. -- Abstract: Polymerase chain reaction in conjunction with enzyme-linked immunosorbent assay (PCR–ELISA) is a well-established technique that provides a suitable rapid, sensitive, and selective method for a broad range of applications. However, the need for precise rapid temperature cycling of PCR is an important drawback that can be overcome by employing isothermal amplification reactions such as recombinase polymerase amplification (RPA). The RPA–ELISA combination is proposed for amplification at a low, constant temperature (40 °C) in a short time (40 min), for the hybridisation of labelled products to specific 5′-biotinylated probes/streptavidin in coated microtiter plates at room temperature, and for detection by colorimetric immunoassay. RPA–ELISA was applied to screen common safety threats in foodstuffs, such as allergens (hazelnut, peanut, soybean, tomato, and maize), genetically modified organisms (P35S and TNOS), pathogenic bacteria (Salmonella sp. and Cronobacter sp.), and fungi (Fusarium sp.). Satisfactory sensitivity and reproducibility results were achieved for all the targets. The RPA–ELISA technique does away with thermocycling and provides a suitable sensitive, specific, and cost-effective method for routine applications, and proves particularly useful for resource-limited settings

  12. Microarray MAPH: accurate array-based detection of relative copy number in genomic DNA

    Directory of Open Access Journals (Sweden)

    Chan Alan

    2006-06-01

    Full Text Available Abstract Background Current methods for measurement of copy number do not combine all the desirable qualities of convenience, throughput, economy, accuracy and resolution. In this study, to improve the throughput associated with Multiplex Amplifiable Probe Hybridisation (MAPH we aimed to develop a modification based on the 3-Dimensional, Flow-Through Microarray Platform from PamGene International. In this new method, electrophoretic analysis of amplified products is replaced with photometric analysis of a probed oligonucleotide array. Copy number analysis of hybridised probes is based on a dual-label approach by comparing the intensity of Cy3-labelled MAPH probes amplified from test samples co-hybridised with similarly amplified Cy5-labelled reference MAPH probes. The key feature of using a hybridisation-based end point with MAPH is that discrimination of amplified probes is based on sequence and not fragment length. Results In this study we showed that microarray MAPH measurement of PMP22 gene dosage correlates well with PMP22 gene dosage determined by capillary MAPH and that copy number was accurately reported in analyses of DNA from 38 individuals, 12 of which were known to have Charcot-Marie-Tooth disease type 1A (CMT1A. Conclusion Measurement of microarray-based endpoints for MAPH appears to be of comparable accuracy to electrophoretic methods, and holds the prospect of fully exploiting the potential multiplicity of MAPH. The technology has the potential to simplify copy number assays for genes with a large number of exons, or of expanded sets of probes from dispersed genomic locations.

  13. Microarray MAPH: accurate array-based detection of relative copy number in genomic DNA.

    Science.gov (United States)

    Gibbons, Brian; Datta, Parikkhit; Wu, Ying; Chan, Alan; Al Armour, John

    2006-06-30

    Current methods for measurement of copy number do not combine all the desirable qualities of convenience, throughput, economy, accuracy and resolution. In this study, to improve the throughput associated with Multiplex Amplifiable Probe Hybridisation (MAPH) we aimed to develop a modification based on the 3-Dimensional, Flow-Through Microarray Platform from PamGene International. In this new method, electrophoretic analysis of amplified products is replaced with photometric analysis of a probed oligonucleotide array. Copy number analysis of hybridised probes is based on a dual-label approach by comparing the intensity of Cy3-labelled MAPH probes amplified from test samples co-hybridised with similarly amplified Cy5-labelled reference MAPH probes. The key feature of using a hybridisation-based end point with MAPH is that discrimination of amplified probes is based on sequence and not fragment length. In this study we showed that microarray MAPH measurement of PMP22 gene dosage correlates well with PMP22 gene dosage determined by capillary MAPH and that copy number was accurately reported in analyses of DNA from 38 individuals, 12 of which were known to have Charcot-Marie-Tooth disease type 1A (CMT1A). Measurement of microarray-based endpoints for MAPH appears to be of comparable accuracy to electrophoretic methods, and holds the prospect of fully exploiting the potential multiplicity of MAPH. The technology has the potential to simplify copy number assays for genes with a large number of exons, or of expanded sets of probes from dispersed genomic locations.

  14. Assaying Cellular Viability Using the Neutral Red Uptake Assay.

    Science.gov (United States)

    Ates, Gamze; Vanhaecke, Tamara; Rogiers, Vera; Rodrigues, Robim M

    2017-01-01

    The neutral red uptake assay is a cell viability assay that allows in vitro quantification of xenobiotic-induced cytotoxicity. The assay relies on the ability of living cells to incorporate and bind neutral red, a weak cationic dye, in lysosomes. As such, cytotoxicity is expressed as a concentration-dependent reduction of the uptake of neutral red after exposure to the xenobiotic under investigation. The neutral red uptake assay is mainly used for hazard assessment in in vitro toxicology applications. This method has also been introduced in regulatory recommendations as part of 3T3-NRU-phototoxicity-assay, which was regulatory accepted in all EU member states in 2000 and in the OECD member states in 2004 as a test guideline (TG 432). The present protocol describes the neutral red uptake assay using the human hepatoma cell line HepG2, which is often employed as an alternative in vitro model for human hepatocytes. As an example, the cytotoxicity of acetaminophen and acetyl salicylic acid is assessed.

  15. A novel multiparametric flow cytometry-based cytotoxicity assay simultaneously immunophenotypes effector cells: comparisons to a 4 h 51Cr-release assay.

    Science.gov (United States)

    Kim, G G; Donnenberg, V S; Donnenberg, A D; Gooding, W; Whiteside, T L

    2007-08-31

    Natural killer (NK) cell-or T cell-mediated cytotoxicity traditionally is measured in 4-16 h (51)Cr-release assays (CRA). A new four-color flow cytometry-based cytotoxicity assay (FCC) was developed to simultaneously measure NK cell cytotoxicity and NK cell phenotype (CD3(-)CD16(+)CD56(+)). Target cells, K562 or Daudi, were labeled with Cell Tracker Orange (CTO) prior to the addition of effector cells. Following co-incubation, 7 amino-actinomycin D (7-AAD) was added to measure death of target cells. The phenotype of effectors, viability of targets, the formation of tumor-effector cell conjugates and absolute numbers of all cells were measured based on light scatter (FSC/SSC), double discrimination of the fluorescence peak integral and height, and fluorescence intensity. Kinetic studies (0.5 and 1 to 4 h) at different effector to target (E:T) cell ratios (50, 25, 12, and 6) confirmed that the 3 h incubation was optimal. The FCC assay is more sensitive than the CRA, has a coefficient of variation (CV) 8-13% and reliably measures NK cell-or lymphokine-activated killer (LAK) cell-mediated killing of target cells in normal controls and subjects with cancer. The FCC assay can be used to study a range of phenotypic attributes, in addition to lytic activity of various subsets of effector cells, without radioactive tracers and thus, it is relatively inexpensive. The FCC assay has a potential for providing information about molecular interactions underlying target cell lysis and thus becoming a major tool for studies of disease pathogenesis as well as development of novel immune therapies.

  16. Detection and Characterisation of Anaplasma marginale and A. centrale in South Africa

    Directory of Open Access Journals (Sweden)

    Paidashe Hove

    2018-03-01

    Full Text Available Bovine anaplasmosis is endemic in South Africa and it has a negative economic impact on cattle farming. An improved understanding of Anaplasma marginale and Anaplasma marginale variety centrale (A. centrale transmission, together with improved tools for pathogen detection and characterisation, are required to inform best management practices. Direct detection methods currently in use for A. marginale and A. centrale in South Africa are light microscopic examination of tissue and organ smears, conventional, nested, and quantitative real-time polymerase chain reaction (qPCR assays, and a reverse line blot hybridisation assay. Of these, qPCR is the most sensitive for detection of A. marginale and A. centrale in South Africa. Serological assays also feature in routine diagnostics, but cross-reactions prevent accurate species identification. Recently, genetic characterisation has confirmed that A. marginale and A. centrale are separate species. Diversity studies targeting Msp1a repeats for A. marginale and Msp1aS repeats for A. centrale have revealed high genetic variation and point to correspondingly high levels of variation in A. marginale outer membrane proteins (OMPs, which have been shown to be potential vaccine candidates in North American studies. Information on these OMPs is lacking for South African A. marginale strains and should be considered in future recombinant vaccine development studies, ultimately informing the development of regional or global vaccines.

  17. Detection of hepatitis B surface antigen by solid phase radioimmunoassay and immunometric assay (using enhanced luminescence)

    International Nuclear Information System (INIS)

    Nicholson, S.; Efandis, T.; Gust, I.

    1991-01-01

    A study was performed to assess the sensitivity and specificity of the amerlite monoclonal immunoassay for detection of hepatitis B surface antigen (HBsAG) by comparison with the Abbott Ausria II radioimmunoassay (RI). Serial bleeds from 34 patients with acute or chronic hepatitis B were tested by both assays. The Abbott Ausria II assay detected HBsAG longer than the Amersham Amerlite assay on two occasions and earlier on one occasion. Twelve patients with low HBsAg positive results (confirmed by Ausria II) were tested by the Amerlite assay, four were repeatably positive, five repeatably negative and three gave borderline results (which on repeat testing were negative). A similar trend was seen when a panel of sera containing known concentrations of HBsAG was tested. Replicate testing of 10 specimens eight times showed very good reproducibility by the Amerlite assay. Overall, the specificity of both assays was comparable, however differences in sensitivity were observed. 3 tabs

  18. Sphingosine 1-phosphate lyase enzyme assay using a BODIPY-labeled substrate

    International Nuclear Information System (INIS)

    Bandhuvula, Padmavathi; Li Zaiguo; Bittman, Robert; Saba, Julie D.

    2009-01-01

    Sphingosine 1-phosphate lyase (SPL) is responsible for the irreversible catabolism of sphingosine 1-phosphate, which signals through five membrane receptors to mediate cell stress responses, angiogenesis, and lymphocyte trafficking. The standard assay for SPL activity utilizes a radioactive dihydrosphingosine 1-phosphate substrate and is expensive and cumbersome. In this study, we describe an SPL assay that employs an ω-labeled BODIPY-sphingosine 1-phosphate substrate, allowing fluorescent product detection by HPLC and incorporating advantages of the BODIPY fluorophore. The major aldehyde product is confirmed by reaction with 2,4-dinitrophenylhydrazine. The SPL-catalyzed reaction is linear over a 30 min time period and yields a K m of 35 μM for BODIPY-sphingosine 1-phosphate.

  19. Random assay in radioimmunoassay: Feasibility and application compared with batch assay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Min; Lee, Hwan Hee; Park, Sohyun; Kim, Tae Sung; Kim, Seok Ki [Dept. of Nuclear MedicineNational Cancer Center, Goyang (Korea, Republic of)

    2016-12-15

    The batch assay has been conventionally used for radioimmunoassay (RIA) because of its technical robustness and practical convenience. However, it has limitations in terms of the relative lag of report time due to the necessity of multiple assays in a small number of samples compared with the random assay technique. In this study, we aimed to verify whether the random assay technique can be applied in RIA and is feasible in daily practice. The coefficients of variation (CVs) of eight standard curves within a single kit were calculated in a CA-125 immunoradiometric assay (IRMA) for the reference of the practically ideal CV of the CA-125 kit. Ten standard curves of 10 kits from 2 prospectively collected lots (pLot) and 85 standard curves of 85 kits from 3 retrospectively collected lots (Lot) were obtained. Additionally, the raw measurement data of both 170 control references and 1123 patients' sera were collected retrospectively between December 2015 and January 2016. A standard curve of the first kit of each lot was used as a master standard curve for a random assay. The CVs of inter-kits were analyzed in each lot, respectively. All raw measurements were normalized by decay and radioactivity. The CA-125 values from control samples and patients' sera were compared using the original batch assay and random assay. In standard curve analysis, the CVs of inter-kits in pLots and Lots were comparable to those within a single kit. The CVs from the random assay with normalization were similar to those from the batch assay in the control samples (CVs % of low/high concentration; Lot1 2.71/1.91, Lot2 2.35/1.83, Lot3 2.83/2.08 vs. Lot1 2.05/1.21, Lot2 1.66/1.48, Lot3 2.41/2.14). The ICCs between the batch assay and random assay using patients' sera were satisfactory (Lot1 1.00, Lot2 0.999, Lot3 1.00). The random assay technique could be successfully applied to the conventional CA-125 IRMA kits. The random assay showed strong agreement with the batch assay. The

  20. Validation of the Filovirus Plaque Assay for Use in Preclinical Studies

    Directory of Open Access Journals (Sweden)

    Amy C. Shurtleff

    2016-04-01

    Full Text Available A plaque assay for quantitating filoviruses in virus stocks, prepared viral challenge inocula and samples from research animals has recently been fully characterized and standardized for use across multiple institutions performing Biosafety Level 4 (BSL-4 studies. After standardization studies were completed, Good Laboratory Practices (GLP-compliant plaque assay method validation studies to demonstrate suitability for reliable and reproducible measurement of the Marburg Virus Angola (MARV variant and Ebola Virus Kikwit (EBOV variant commenced at the United States Army Medical Research Institute of Infectious Diseases (USAMRIID. The validation parameters tested included accuracy, precision, linearity, robustness, stability of the virus stocks and system suitability. The MARV and EBOV assays were confirmed to be accurate to ±0.5 log10 PFU/mL. Repeatability precision, intermediate precision and reproducibility precision were sufficient to return viral titers with a coefficient of variation (%CV of ≤30%, deemed acceptable variation for a cell-based bioassay. Intraclass correlation statistical techniques for the evaluation of the assay’s precision when the same plaques were quantitated by two analysts returned values passing the acceptance criteria, indicating high agreement between analysts. The assay was shown to be accurate and specific when run on Nonhuman Primates (NHP serum and plasma samples diluted in plaque assay medium, with negligible matrix effects. Virus stocks demonstrated stability for freeze-thaw cycles typical of normal usage during assay retests. The results demonstrated that the EBOV and MARV plaque assays are accurate, precise and robust for filovirus titration in samples associated with the performance of GLP animal model studies.

  1. Matrix effects of TRU [transuranic] assays using the SWEPP PAN assay system

    International Nuclear Information System (INIS)

    Smith, J.R.

    1990-08-01

    The Drum Assay System (DAS) at the Stored Waste Experimental Pilot Plant (SWEPP) is a second-generation active-passive neutron assay system. It has been used to assay over 5000 208-liter drums of transuranic waste from the Rocky Flats Plant (RFP). Data from these assays have been examined and compared with the assays performed at Rocky Flats, mainly utilize counting of 239 Pu gamma rays. For the most part the passive assays are in very good agreement with the Rocky Flats assays. The active assays are strongly correlated with the results of the other two methods, but require matrix-dependent correction factors beyond those provided by the system itself. A set of matrix-dependent correction factors has been developed from the study of the assay results. 3 refs., 4 figs., 3 tabs

  2. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  3. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  4. Antioxidant properties of species from the Brazilian cerrado by different assays

    Directory of Open Access Journals (Sweden)

    K.S. Farias

    2013-01-01

    Full Text Available The purpose of this study was to screen the antioxidant activity of medicinal plant extracts from the Brazilian cerrado, through other methods than the total phenolic content and its correlation with the antioxidant activity. Ethanolic extracts of ten species were evaluated through three antioxidant assays, in vitro, including 2,2-diphenyl-1-picrylhydrazyl (DPPH, total antioxidant activity and reducing power; and by using the Folin-Ciocalteu method the total phenolic content was determined. Ethanolic extracts of Stryphnodendron obovatum, Cecropia pachystachya and Duguetia furfuraceae showed strong antioxidant activity (IC50<5 µg mL-1 in the DPPH free radical scavenging assay; the species Vernonia phosphorea, Hymenaea stignocarpa and Jacaranda ulei may also be highlighted. These results were confirmed in the assays of total antioxidant capacity and reducing power. The extracts of S. obovatum and V. phosphorea showed an abundant phenolic content; therefore, the phenolic content may play a role in the antioxidant activity. These two species, traditionally used in Brazil, showed great power in these assay systems and may be a promising source for the development of natural antioxidants and future candidates for phytochemical and pharmacological studies in related diseases.

  5. Detection and confirmation of Clostridium botulinum in water used for cooling at a plant producing low-acid canned foods.

    Science.gov (United States)

    Sachdeva, Amita; Defibaugh-Chávez, Stephanie L H; Day, James B; Zink, Donald; Sharma, Shashi K

    2010-11-01

    Our laboratory tested water samples used for cooling low-acid canned foods at a canning facility under investigation by the U.S. Food and Drug Administration. We used an enzyme-linked immunosorbent assay with digoxigenin-labeled antibodies (DIG-ELISA) and real-time PCR as screening methods and confirmed the presence of neurotoxin-producing Clostridium botulinum in the samples by mouse bioassay.

  6. Detection and Confirmation of Clostridium botulinum in Water Used for Cooling at a Plant Producing Low-Acid Canned Foods▿

    OpenAIRE

    Sachdeva, Amita; Defibaugh-Chávez, Stephanie L. H.; Day, James B.; Zink, Donald; Sharma, Shashi K.

    2010-01-01

    Our laboratory tested water samples used for cooling low-acid canned foods at a canning facility under investigation by the U.S. Food and Drug Administration. We used an enzyme-linked immunosorbent assay with digoxigenin-labeled antibodies (DIG-ELISA) and real-time PCR as screening methods and confirmed the presence of neurotoxin-producing Clostridium botulinum in the samples by mouse bioassay.

  7. Radioreceptor opioid assay

    International Nuclear Information System (INIS)

    Miller, R.J.; Chang, K.-J.

    1981-01-01

    A radioreceptor assay is described for assaying opioid drugs in biological fluids. The method enables the assay of total opioid activity, being specific for opioids as a class but lacking specificity within the class. A radio-iodinated opioid and the liquid test sample are incubated with an opiate receptor material. The percentage inhibition of the binding of the radio-iodinated compound to the opiate receptor is calculated and the opioid activity of the test liquid determined from a standard curve. Examples of preparing radio-iodinated opioids and assaying opioid activity are given. A test kit for the assay is described. Compared to other methods, this assay is cheap, easy and rapid. (U.K.)

  8. A post-infection serologic assessment of cattle herd immune status after a vesicular stomatitis outbreak and the agreement of antibody assays.

    Science.gov (United States)

    Berninger, Mary Lou; O'Hearn, Emily; Lomkin, Richanne; Newens, Ken; Havas, Karyn A

    2018-03-01

    Vesicular stomatitis (VS) is a vesicular disease of horses, cattle, and pigs in the Western Hemisphere caused by viruses in the genus Vesiculovirus. Disease manifests as vesicles and erosions on the oral mucosa, teats, prepuce, and coronary band, and is similar in presentation to foot-and-mouth disease. Laboratory confirmation is therefore required. Conventional assays include competitive (c)ELISA and complement fixation (CF). The cELISA provides more accurate herd-level detection of VSV-exposed cattle, but may lack the ability to capture fluctuating antibody levels in individual animals. The CF assay can confirm newly infected animals because of its ability to detect antigen-antibody complexes, thus is considered to be indicative of IgM. We evaluated the immune status of 2 herds affected by VSV in 2014 by testing sera collected in June 2015. Two conventional assays were compared to a novel IgM-IgG ELISA. When sampled in 2015, both herds had detectable VSV-specific antibodies; 18% and 36% of animals tested by cELISA and 2% and 8% of animals tested by CF were positive. The novel IgM-IgG assay exhibited fair agreement (adjusted kappa score of 48) with the conventional assays, and should be evaluated further to assess its ability to replace the 2 separate assays with a single assay system, or for its ability to replace the CF assay as a more sensitive method for defining newly exposed animals.

  9. Development of an opioid self-administration assay to study drug seeking in zebrafish.

    Science.gov (United States)

    Bossé, Gabriel D; Peterson, Randall T

    2017-09-29

    The zebrafish (Danio rerio) has become an excellent tool to study mental health disorders, due to its physiological and genetic similarity to humans, ease of genetic manipulation, and feasibility of small molecule screening. Zebrafish have been shown to exhibit characteristics of addiction to drugs of abuse in non-contingent assays, including conditioned place preference, but contingent assays have been limited to a single assay for alcohol consumption. Using inexpensive electronic, mechanical, and optical components, we developed an automated opioid self-administration assay for zebrafish, enabling us to measure drug seeking and gain insight into the underlying biological pathways. Zebrafish trained in the assay for five days exhibited robust self-administration, which was dependent on the function of the μ-opioid receptor. In addition, a progressive ratio protocol was used to test conditioned animals for motivation. Furthermore, conditioned fish continued to seek the drug despite an adverse consequence and showed signs of stress and anxiety upon withdrawal of the drug. Finally, we validated our assay by confirming that self-administration in zebrafish is dependent on several of the same molecular pathways as in other animal models. Given the ease and throughput of this assay, it will enable identification of important biological pathways regulating drug seeking and could lead to the development of new therapeutic molecules to treat addiction. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Antibody class capture assay (ACCA) for rubella-specific IgM antibody.

    Science.gov (United States)

    Isaac, M; Payne, R A

    1982-01-01

    Enzyme-linked immunosorbent assays for IgM antirubella were carried out on 1,546 sera, using an IgM capture method with a F (ab')2 conjugate (ACCA). Under the conditions described, sera containing IgM antirubella bound up to 15 times as much enzyme activity as negative specimens. Paired serum specimens from 27 patients, serial serum specimens from 6 patients, and single serum specimens from 15 patients who had had recent rubella were examined by the haemagglutination inhibition test (HAI) in the presence and absence of 2-mercaptoethanol following sucrose density gradient centrifugation (SDGC). ACCA confirmed all the results found with HAI following SDGC. Specimens were examined from ten patients with congenital rubella; ACCA confirmed the results found with both immunofluorescence following SDGC and radioimmunoassay. Pre- and post-vaccination specimens from 123 patients who had been vaccinated against rubella were examined. An IgM response could only be demonstrated in the 57 cases when IgG was absent in the first specimen. The specificity of the assay was confirmed by testing 31 serum specimens from rubella immune patients that also contained rheumatoid factor, 163 serum specimens from patients with acute infections other than rubella, and 12 serum specimens from infants with miscellaneous neonatal abnormalities other than congenital rubella. The ACCA proved a simple, sensitive, and specific test for IgM antirubella and the results compared favourably with those obtained by the SDGC technique.

  11. Loop-mediated isothermal amplification assays for screening of bacterial integrons

    Directory of Open Access Journals (Sweden)

    Guangchao Yu

    2014-01-01

    Full Text Available BACKGROUND: The occurrence and prevalence of integrons in clinical microorganisms and their role played in antimicrobial resistance have been well studied recently. As screening and detection of integrons are concerned, current diagnostic methodologies are restricted by significant drawbacks and novel methods are required for integrons detection. RESULTS: In this study, three loop-mediated isothermal amplification (LAMP assays targeting on class 1, 2 and 3 integrons were implemented and evaluated. Optimization of these detection assays were performed, including studing on the reaction temperature, volume, time, sensitivity and specificity (both primers and targets. Application of the established LAMP assays were further verified on a total of 1082 isolates (previously identified to be 397 integron-positive and 685 integron-negative strains. According to the results, the indispensability of each primer had been confirmed and the optimal reaction temperature, volume and time were found to be 65°C, 45 min and 25 µL, respectively. As application was concerned, 361, 28 and 8 isolates carrying intI1, intI2 and intI3 yielded positive amplicons, respectively. Other 685 integron-negative bacteria were negative for the integron-screening LAMP assays, totaling the detection rate and specificity to be 100%. CONCLUSIONS: The intI1-, intI2- and intI3-LAMP assays established in this study were demonstrated to be the valid and rapid detection methodologies for the screening of bacterial integrons.

  12. Reassessing the reliability of the salivary cortisol assay for the diagnosis of Cushing syndrome.

    Science.gov (United States)

    Zhang, Qian; Dou, Jingtao; Gu, Weijun; Yang, Guoqing; Lu, Juming

    2013-10-01

    The cortisol concentration in saliva is 10-fold lower than total serum cortisol and accurately reflects the serum concentration, both levels being lowest around midnight. The salivary cortisol assay measures free cortisol and is unaffected by confounding factors. This study analysed published data on the sensitivity and specificity of salivary cortisol levels in the diagnosis of Cushing syndrome. Data from studies on the use of different salivary cortisol assay techniques in the diagnosis of Cushing syndrome, published between 1998 and 2012 and retrieved using Ovid MEDLINE®, were analysed for variance and correlation. For the 11 studies analysed, mean sensitivity and specificity of the salivary cortisol assay were both >90%. Repeated measurements were easily made with this assay, enabling improved diagnostic accuracy in comparison with total serum cortisol measurements. This analysis confirms the reliability of the saliva cortisol assay as pragmatic tool for the accurate diagnosis of Cushing syndrome. With many countries reporting a rising prevalence of metabolic syndrome, diabetes and obesity--in which there is often a high circulating cortisol level--salivary cortisol measurement will help distinguish these states from Cushing syndrome.

  13. Rapid, actionable diagnosis of urban epidemic leptospirosis using a pathogenic Leptospira lipL32-based real-time PCR assay.

    Science.gov (United States)

    Riediger, Irina N; Stoddard, Robyn A; Ribeiro, Guilherme S; Nakatani, Sueli M; Moreira, Suzana D R; Skraba, Irene; Biondo, Alexander W; Reis, Mitermayer G; Hoffmaster, Alex R; Vinetz, Joseph M; Ko, Albert I; Wunder, Elsio A

    2017-09-01

    With a conservatively estimated 1 million cases of leptospirosis worldwide and a 5-10% fatality rate, the rapid diagnosis of leptospirosis leading to effective clinical and public health decision making is of high importance, and yet remains a challenge. Based on parallel, population-based studies in two leptospirosis-endemic regions in Brazil, a real-time PCR assay which detects lipL32, a gene specifically present in pathogenic Leptospira, was assessed for the diagnostic effectiveness and accuracy. Patients identified by active hospital-based surveillance in Salvador and Curitiba during large urban leptospirosis epidemics were tested. Real-time PCR reactions were performed with DNA-extracted samples obtained from 127 confirmed and 23 unconfirmed cases suspected of leptospirosis, 122 patients with an acute febrile illness other than leptospirosis, and 60 healthy blood donors. The PCR assay had a limit of detection of 280 Leptospira genomic equivalents/mL. Sensitivity for confirmed cases was 61% for whole blood and 29% for serum samples. Sensitivity was higher (86%) for samples collected within the first 6 days after onset of illness compared to those collected after 7 days (34%). The real-time PCR assay was able to detect leptospiral DNA in blood from 56% of serological non-confirmed cases. The overall specificity of the assay was 99%. These findings indicate that real-time PCR may be a reliable tool for early diagnosis of leptospirosis, which is decisive for clinical management of severe and life-threatening cases and for public health decision making.

  14. Multiplex PCR-based assay for detection of Bordetella pertussis in nasopharyngeal swab specimens.

    Science.gov (United States)

    Wadowsky, R M; Michaels, R H; Libert, T; Kingsley, L A; Ehrlich, G D

    1996-11-01

    A multiplex PCR-based assay was developed for the detection of Bordetella pertussis in nasopharyngeal swab specimens. The assay simultaneously amplified two separate DNA targets (153 and 203 bp) within a B. pertussis repetitive element and a 438-bp target within the beta-actin gene of human DNA (PCR amplification control). PCR products were detected by a sensitive and specific liquid hybridization gel retardation assay. A total of 496 paired nasopharyngeal swab specimens were tested by both the PCR-based assay and culture. Although 30 (6%) of the specimens inhibited the amplification of the beta-actin target, in all 29 specimens studied, the inhibition disappeared on repeat testing or was easily overcome with a 1:8 dilution or less of specimen digest. Of the 495 specimen pairs yielding a final evaluable result by the PCR-based assay, 19.0% were positive by the PCR-based assay, whereas 13.9% were positive by culture (P < 0.0001). After resolving the PCR-positive, culture-negative results by testing an additional aliquot from these specimens by the multiplex PCR-based assay, the PCR-based assay had a sensitivity and specificity of 98.9 and 99.7%, respectively, compared with values of 73.4 and 100%, respectively, for culture. In comparison with patients with culture-confirmed pertussis, those with PCR-positive, culture-negative results were older and more likely to have had prolonged cough, immunization with pertussis vaccine, or treatment with erythromycin. This multiplex PCR-based assay is substantially more sensitive than culture and identifies specimens that contain inhibitors of PCR.

  15. A High Sensitivity Micro Format Chemiluminescence Enzyme Inhibition Assay for Determination of Hg(II

    Directory of Open Access Journals (Sweden)

    Kanchanmala Deshpande

    2010-06-01

    Full Text Available A highly sensitive and specific enzyme inhibition assay based on alcohol oxidase (AlOx and horseradish peroxidase (HRP for determination of mercury Hg(II in water samples has been presented. This article describes the optimization and miniaturization of an enzymatic assay using a chemiluminescence reaction. The analytical performance and detection limit for determination of Hg(II was optimized in 96 well plates and further extended to 384 well plates with a 10-fold reduction in assay volume. Inhibition of the enzyme activity by dissolved Hg(II was found to be linear in the range 5–500 pg.mL−1 with 3% CVin inter-batch assay. Due to miniaturization of assay in 384 well plates, Hg(II was measurable as low as 1 pg.mL−1 within15 min. About 10-fold more specificity of the developed assay for Hg(II analysis was confirmed by challenging with interfering divalent metal ions such as cadmium Cd(II and lead Pb(II. Using the proposed assay we could successfully demonstrate that in a composite mixture of Hg(II, Cd(II and Pb(II, inhibition by each metal ion is significantly enhanced in the presence of the others. Applicability of the proposed assay for the determination of the Hg(II in spiked drinking and sea water resulted in recoveries ranging from 100–110.52%.

  16. Diagnostic efficacy of molecular assays for the viral haemorrhagic septicaemia virus isolates from the Czech Republic

    Directory of Open Access Journals (Sweden)

    Ľubomír Pojezdal

    2017-01-01

    Full Text Available The diagnostic properties of the one-step real-time reverse-transcription polymerase chain reaction assay for viral haemorrhagic septicaemia virus detection were compared to methods currently in use in the Czech Republic, namely, virus isolation using the cell culture and conventional reverse-transcription polymerase chain reaction followed by the nested polymerase chain reaction. The assays were tested on a panel of 25 archived viral haemorrhagic septicaemia isolates and 8 archived infectious haematopoietic necrosis isolates obtained from monitoring and/or outbreaks of the diseases among farmed salmonids in the Czech Republic. The ability to detect the presence of the virus in the tissues of fish was tested on additional 32 field samples collected from the rainbow trout (Oncorhynchus mykiss, brown trout (Salmo trutta and brook trout (Salvelinus fontinalis. The real-time assay showed the highest analytic sensitivity by detecting the presence of viral nucleic acid in samples with 10-7 dilution, whereas the sensitivity of the conventional polymerase chain reaction peaked at 10-5. Diagnostic specificity of both molecular assays was confirmed by absence of cross-reactivity with the infectious haematopoietic necrosis virus isolates. This, along with consistent results in the detection of the virus in the fish tissues, confirms that the one-step real-time reverse-transcription polymerase chain reaction is currently an optimal stand-alone diagnostic method for the detection of the viral haemorrhagic septicaemia virus.

  17. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  18. 45,X/46,X dic (Y) mosaicism in a phenotypic male.

    OpenAIRE

    Batstone, P J; Faed, M J; Jung, R T; Gosden, J

    1991-01-01

    Cytogenetic analysis, confirmed by in situ hybridisation studies, showed a mosaic 45,X/46,X dic (Y) (q12) karyotype in a 14 year old boy who was initially diagnosed as having Noonan's syndrome. He made an early response to recombinant growth hormone; this suggests that this treatment may improve final height.

  19. Development and Validation of an Enzyme-Linked Immunosorbent Assay for the Detection of Binding Anti-Drug Antibodies against Interferon Beta

    Directory of Open Access Journals (Sweden)

    Kathleen Ingenhoven

    2017-07-01

    Full Text Available ObjectiveTo develop and validate a method for the detection of binding anti-drug antibodies (ADAs against interferon beta (IFN-β in human serum as part of a European initiative (ABIRISK aimed at the prediction and analysis of clinical relevance of anti-biopharmaceutical immunization to minimize the risk.MethodA two-tiered bridging enzyme-linked immunosorbent assay (ELISA format was selected and validated according to current recommendations. Screening assay: ADA in serum samples form complexes with immobilized IFN-β and biotinylated IFN-β, which are then detected using HRP labeled Streptavidin and TMB substrate. Confirmation assay: Screen “putative positive” samples are tested in the presence of excess drug (preincubation of sera with 0.3 µg/mL of soluble IFN-β and percentage of inhibition is calculated.ResultsThe assay is precise, and the sensitivity of the assay was confirmed to be 26 ng/mL using commercially available polyclonal rabbit antihuman IFN-β in human sera as the positive control.ConclusionAn ultrasensitive ELISA for IFN-β-binding ADA testing has been validated. This will form the basis to assess anti-biopharmaceutical immunization toward IFN-β with regards to its clinical relevance and may allow for the development of predictive tools, key aims within the ABIRISK consortium.

  20. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution

    Directory of Open Access Journals (Sweden)

    Ta-Wei Liu

    2015-01-01

    Full Text Available Hepatitis B virus surface antigen (HBsAg levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay, compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys. A total of 130 sera samples obtained from 87 hepatitis B virus (HBV-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44–9.53% and R2 = 0.996–1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p  0.93 in all cases. In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.

  1. Selection of non-destructive assay methods: Neutron counting or calorimetric assay?

    International Nuclear Information System (INIS)

    Cremers, T.L.; Wachter, J.R.

    1994-01-01

    The transition of DOE facilities from production to D ampersand D has lead to more measurements of product, waste, scrap, and other less attractive materials. Some of these materials are difficult to analyze by either neutron counting or calorimetric assay. To determine the most efficacious analysis method, variety of materials, impure salts and hydrofluorination residues have been assayed by both calorimetric assay and neutron counting. New data will be presented together with a review of published data. The precision and accuracy of these measurements are compared to chemistry values and are reported. The contribution of the gamma ray isotopic determination measurement to the overall error of the calorimetric assay or neutron assay is examined and discussed. Other factors affecting selection of the most appropriate non-destructive assay method are listed and considered

  2. Detection of 12 respiratory viruses by duplex real time PCR assays in respiratory samples.

    Science.gov (United States)

    Arvia, Rosaria; Corcioli, Fabiana; Ciccone, Nunziata; Della Malva, Nunzia; Azzi, Alberta

    2015-12-01

    Different viruses can be responsible for similar clinical manifestations of respiratory infections. Thus, the etiological diagnosis of respiratory viral diseases requires the detection of a large number of viruses. In this study, 6 duplex real-time PCR assays, using EvaGreen intercalating dye, were developed to detect 12 major viruses responsible for respiratory diseases: influenza A and B viruses, enteroviruses (including enterovirus spp, and rhinovirus spp), respiratory syncytial virus, human metapneumovirus, coronaviruses group I (of which CoV 229E and CoV NL63 are part) and II (including CoV OC43 and CoV HKU1), parainfluenza viruses type 1, 2, 3 and 4, human adenoviruses and human bocaviruses. The 2 target viruses of each duplex reaction were distinguishable by the melting temperatures of their amplicons. The 6 duplex real time PCR assays were applied for diagnostic purpose on 202 respiratory samples from 157 patients. One hundred fifty-seven samples were throat swabs and 45 were bronchoalveolar lavages. The results of the duplex PCR assays were confirmed by comparison with a commercial, validated, assay; in addition, the positive results were confirmed by sequencing. The analytical sensitivity of the duplex PCR assays varied from 10(3) copies/ml to 10(4) copies/ml. For parainfluenza virus 2 only it was 10(5) copies/ml. Seventy clinical samples (35%) from 55 patients (30 children and 25 adults) were positive for 1 or more viruses. In adult patients, influenza A virus was the most frequently detected respiratory virus followed by rhinoviruses. In contrast, respiratory syncytial virus was the most common virus in children, followed by enteroviruses, influenza A virus and coronavirus NL63. The small number of samples/patients does not allow us to draw any epidemiological conclusion. Altogether, the results of this study indicate that the 6 duplex PCR assays described in this study are sensitive, specific and cost-effective. Thus, this assay could be

  3. Thermostability of IFN-γ and IP-10 release assays for latent infection with Mycobacterium tuberculosis

    DEFF Research Database (Denmark)

    Blauenfeldt, Thomas; Wagner, Dirk; Aabye, Martine Grosos

    2016-01-01

    accuracy of IP-10 release assay and IGRAs. RESULTS: We included 65 patients with confirmed pulmonary tuberculosis and 160 healthy controls from 6 European centres collaborating in the TBnet. In patients, IP-10 responses increased 1.07 (IQR 0.90-1.36) fold and IFN-γ responses decreased 0.88 (IQR 0......INTRODUCTION: Interferon-γ (IFN-γ) inducible protein 10kD (IP-10) and IFN-γ release assays (IGRAs) are immunodiagnostic tests aiming to identify the presence of specific cellular immune responses, interpreted as markers for latent infection with Mycobacterium tuberculosis. Incubation at higher...

  4. Confirmed detection of Cyclospora cayetanesis, Encephalitozoon intestinalis and Cryptosporidium parvum in water used for drinking.

    Science.gov (United States)

    Dowd, Scot E; John, David; Eliopolus, James; Gerba, Charles P; Naranjo, Jaime; Klein, Robert; López, Beatriz; de Mejía, Maricruz; Mendoza, Carlos E; Pepper, Ian L

    2003-09-01

    Human enteropathogenic microsporidia (HEM), Cryptosporidium parvum, Cyclospora cayetanesis, and Giardia lamblia are associated with gastrointestinal disease in humans. To date, the mode of transmission and environmental occurrence of HEM (Encephalitozoon intestinalis and Enterocytozoon bieneusi) and Cyclospora cayetanesis have not been fully elucidated due to lack of sensitive and specific environmental screening methods. The present study was undertaken with recently developed methods, to screen various water sources used for public consumption in rural areas around the city of Guatemala. Water concentrates collected in these areas were subjected to community DNA extraction followed by PCR amplification, PCR sequencing and computer database homology comparison (CDHC). All water samples screened in this study had been previously confirmed positive for Giardia spp. by immunofluorescent assay (IFA). Of the 12 water concentrates screened, 6 showed amplification of microsporidial SSU-rDNA and were subsequently confirmed to be Encephalitozoon intestinalis. Five of the samples allowed for amplification of Cyclospora 18S-rDNA; three of these were confirmed to be Cyclospora cayetanesis while two could not be identified because of inadequate sequence information. Thus, this study represents the first confirmed identification of Cyclospora cayetanesis and Encephalitozoon intestinalis in source water used for consumption. The fact that the waters tested may be used for human consumption indicates that these emerging protozoa may be transmitted by ingestion of contaminated water.

  5. The Single-Molecule Centroid Localization Algorithm Improves the Accuracy of Fluorescence Binding Assays.

    Science.gov (United States)

    Hua, Boyang; Wang, Yanbo; Park, Seongjin; Han, Kyu Young; Singh, Digvijay; Kim, Jin H; Cheng, Wei; Ha, Taekjip

    2018-03-13

    Here, we demonstrate that the use of the single-molecule centroid localization algorithm can improve the accuracy of fluorescence binding assays. Two major artifacts in this type of assay, i.e., nonspecific binding events and optically overlapping receptors, can be detected and corrected during analysis. The effectiveness of our method was confirmed by measuring two weak biomolecular interactions, the interaction between the B1 domain of streptococcal protein G and immunoglobulin G and the interaction between double-stranded DNA and the Cas9-RNA complex with limited sequence matches. This analysis routine requires little modification to common experimental protocols, making it readily applicable to existing data and future experiments.

  6. D-dimer assay for deep vein thrombosis: its role with colour Doppler sonography

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, M.; Bladon, J.; Barker, H

    2000-07-01

    AIM: To evaluate the role of a negative D-dimer assay in the initial management of patients with clinically suspected deep venous thrombosis (DVT), using colour Doppler ultrasound as the primary diagnostic technique. MATERIALS AND METHODS: A double-blind prospective trial was performed on 143 patients with clinically suspected DVT. All patients underwent a D-dimer assay prior to anticoagulant therapy. DVT was confirmed or excluded by diagnostic colour Doppler ultrasound within 24 h of presentation. RESULTS: In nearly one-third of the cases (31.8%), Doppler ultrasound was positive. The D-dimer assay demonstrated a sensitivity of 97.7% with only one false-negative, but the specificity was low at 48.9% with 45 false-positive results. The positive predictive value for D-dimer assay was 48.8%, whilst the important negative predictive value was 98%. CONCLUSION: If D-dimer was used to screen for DVT, and patients with negative results were not imaged, then the imaging workload could be reduced by 35%. In this study one small calf vein thrombus would have been missed by adopting this practice. Bradley, M. (2000)

  7. Phenotypic assays for the determination of coreceptor tropism in HIV-1 infected individuals.

    Science.gov (United States)

    Braun, Patrick; Wiesmann, Frank

    2007-10-15

    Coreceptor tropism antagonists represent a new class of antiretrovirals for the treatment of HIV infection. The knowledge of patients' viral population tropism before the initiation of and during therapy with such compounds may be critical in order to optimize treatment strategies. In this review we focus on the characteristics of phenotypic assays for the determination of HIV coreceptor tropism. Beside traditional phenotypic assays, there are at least four phenotypic recombinant virus assays (RVA) available to predict coreceptor usage: Trofile (Monogram Biosciences), Phenoscript (VIRalliance), XtrackC/ PhenX-R (inPheno) and a platform developed by Virco. Trofile and Phenoscript represent single-cycle assays and are able to determine coreceptor tropism without cocultivation of HIV particles in cell culture. Trofile offers the most clinically validated data with currently about 25,000 analysed samples. The detection of minority variants is a limitation of all population-based assays and varies between 1 and 10%, depending on the assay used. XtrackC/PhenX-R and Virco's platform combine genotypic and phenotypic assays to analyze a patient's sample for tropism. Although all assays are validated for the assessment of coreceptor tropism in different HIV-1 subtypes, there is still a need for further evaluations. Furthermore, the establishment of cut-offs for X4 minority species will be difficult, and is affected by many factors like patient sample quality, the input volume, viral load, the detection limits and PCR variations. Overall, RVAs confirm efficiency and accuracy thus making them suitable for the clinical management of HIV infected individuals treated with coreceptor antagonists.

  8. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    Directory of Open Access Journals (Sweden)

    Carina Ladeira

    2015-06-01

    The results concerning of positive findings by micronuclei and non significant ones by comet assay, are corroborated by Deng et al. (2005 study performed in workers occupationally exposed to methotrexate, also a cytostatic drug. According to Cavallo et al. (2009, the comet assay seems to be more suitable for the prompt evaluation of the genotoxic effects, for instance, of polycyclic aromatic hydrocarbons mixtures containing volatile substances, whereas the micronucleus test seems more appropriate to evaluate the effects of exposure to antineoplastic agents. However, there are studies that observed an increase in both the comet assay and the micronucleus test in nurses handling antineoplastic drugs, although statistical significance was only seen in the comet assay, quite the opposite of our results (Maluf & Erdtmann, 2000; Laffon et al. 2005.

  9. Use of urinary pregnanediol 3-glucuronide to confirm ovulation.

    Science.gov (United States)

    Ecochard, R; Leiva, R; Bouchard, T; Boehringer, H; Direito, A; Mariani, A; Fehring, R

    2013-10-01

    Urinary hormonal markers may assist in increasing the efficacy of Fertility Awareness Based Methods (FABM). This study uses urinary pregnanediol-3a-glucuronide (PDG) testing to more accurately identify the infertile phase of the menstrual cycle in the setting of FABM. Secondary analysis of an observational and simulation study, multicentre, European study. The study includes 107 women and tracks daily first morning urine (FMU), observed the changes in cervical mucus discharge, and ultrasonography to identify the day of ovulation over 326 menstrual cycles. The following three scenarios were tested: (A) use of the daily pregnandiol-3a-glucuronide (PDG) test alone; (B) use of the PDG test after the first positive urine luteinizing hormone (LH) kit result; (C) use of the PDG test after the disappearance of fertile type mucus. Two models were used: (1) one day of PDG positivity; or (2) waiting for three days of PDG positivity before declaring infertility. After the first positivity of a LH test or the end of fertile mucus, three consecutive days of PDG testing over a threshold of 5μg/mL resulted in a 100% specificity for ovulation confirmation. They were respectively associated an identification of an average of 6.1 and 7.6 recognized infertile days. The results demonstrate a clinical scenario with 100% specificity for ovulation confirmation and provide the theoretical background for a future development of a competitive lateral flow assay for the detection of PDG in the urine. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Monoclonal antibodies against human angiotensinogen, their characterization and use in an angiotensinogen enzyme linked immunosorbent assay.

    Science.gov (United States)

    Rubin, I; Lykkegaard, S; Olsen, A A; Selmer, J; Ballegaard, M

    1988-01-01

    Monoclonal antibodies were produced against human angiotensinogen. An enzyme linked immunosorbent assay (ELISA) was developed using a high affinity monoclonal antibody as catching antibody and a polyclonal rabbit anti human angiotensinogen antibody as detecting antibody in a "sandwich" ELISA. Linear range of the ELISA was 15-450 pmol/l of human angiotensinogen. Intra- and inter- assay variation coefficients were in the range of 2% to 8%. A correlation coefficient, r = 0.97, (n = 20), with values obtained by radioimmunoassay. This correlation coefficient, obtained by using both normal and pregnant sera, confirmed that the ELISA fulfill the requirements for clinical useful assay. Characterization of the antibodies were performed with respect to affinity constant and epitopes.

  11. Use of the local lymph node assay in assessment of immune function

    International Nuclear Information System (INIS)

    Berg, Femke A. van den; Baken, Kirsten A.; Vermeulen, Jolanda P.; Gremmer, Eric R.; Steeg, Harry van; Loveren, Henk van

    2005-01-01

    The murine local lymph node assay (LLNA) was originally developed as a predictive test method for the identification of chemicals with sensitizing potential. In this study we demonstrated that an adapted LLNA can also be used as an immune function assay by studying the effects of orally administered immunomodulating compounds on the T-cell-dependent immune response induced by the contact sensitizer 2,4-dinitrochlorobenzene (DNCB). C57Bl/6 mice were treated with the immunotoxic compounds cyclosporin A (CsA), bis(tri-n-butyltin)oxide (TBTO) or benzo[a]pyrene (B[a]P). Subsequently, cell proliferation and interferon-γ (IFN-γ) and interleukin (IL)-4 release were determined in the auricular lymph nodes (LNs) after DNCB application on both ears. Immunosuppression induced by CsA, TBTO and B[a]P was clearly detectable in this application of the LLNA. Cytokine release measurements proved valuable to confirm the results of the cell proliferation assay and to obtain an indication of the effect on Th1/Th2 balance. We believe to have demonstrated the applicability of an adapted LLNA as an immune function assay in the mouse

  12. Use of the local lymph node assay in assessment of immune function.

    Science.gov (United States)

    van den Berg, Femke A; Baken, Kirsten A; Vermeulen, Jolanda P; Gremmer, Eric R; van Steeg, Harry; van Loveren, Henk

    2005-07-01

    The murine local lymph node assay (LLNA) was originally developed as a predictive test method for the identification of chemicals with sensitizing potential. In this study we demonstrated that an adapted LLNA can also be used as an immune function assay by studying the effects of orally administered immunomodulating compounds on the T-cell-dependent immune response induced by the contact sensitizer 2,4-dinitrochlorobenzene (DNCB). C57Bl/6 mice were treated with the immunotoxic compounds cyclosporin A (CsA), bis(tri-n-butyltin)oxide (TBTO) or benzo[a]pyrene, (B[a]P). Subsequently, cell proliferation and interferon-gamma (IFN-gamma) and interleukin (IL)-4 release were determined in the auricular lymph nodes (LNs) after DNCB application on both ears. Immunosuppression induced by CsA, TBTO and B[a]P was clearly detectable in this application of the LLNA. Cytokine release measurements proved valuable to confirm the results of the cell proliferation assay and to obtain an indication of the effect on Th1/Th2 balance. We believe to have demonstrated the applicability of an adapted LLNA as an immune function assay in the mouse.

  13. Rapid, actionable diagnosis of urban epidemic leptospirosis using a pathogenic Leptospira lipL32-based real-time PCR assay.

    Directory of Open Access Journals (Sweden)

    Irina N Riediger

    2017-09-01

    Full Text Available With a conservatively estimated 1 million cases of leptospirosis worldwide and a 5-10% fatality rate, the rapid diagnosis of leptospirosis leading to effective clinical and public health decision making is of high importance, and yet remains a challenge.Based on parallel, population-based studies in two leptospirosis-endemic regions in Brazil, a real-time PCR assay which detects lipL32, a gene specifically present in pathogenic Leptospira, was assessed for the diagnostic effectiveness and accuracy. Patients identified by active hospital-based surveillance in Salvador and Curitiba during large urban leptospirosis epidemics were tested. Real-time PCR reactions were performed with DNA-extracted samples obtained from 127 confirmed and 23 unconfirmed cases suspected of leptospirosis, 122 patients with an acute febrile illness other than leptospirosis, and 60 healthy blood donors.The PCR assay had a limit of detection of 280 Leptospira genomic equivalents/mL. Sensitivity for confirmed cases was 61% for whole blood and 29% for serum samples. Sensitivity was higher (86% for samples collected within the first 6 days after onset of illness compared to those collected after 7 days (34%. The real-time PCR assay was able to detect leptospiral DNA in blood from 56% of serological non-confirmed cases. The overall specificity of the assay was 99%.These findings indicate that real-time PCR may be a reliable tool for early diagnosis of leptospirosis, which is decisive for clinical management of severe and life-threatening cases and for public health decision making.

  14. Screening of HIV-1 Protease Using a Combination of an Ultra-High-Throughput Fluorescent-Based Assay and RapidFire Mass Spectrometry.

    Science.gov (United States)

    Meng, Juncai; Lai, Ming-Tain; Munshi, Vandna; Grobler, Jay; McCauley, John; Zuck, Paul; Johnson, Eric N; Uebele, Victor N; Hermes, Jeffrey D; Adam, Gregory C

    2015-06-01

    HIV-1 protease (PR) represents one of the primary targets for developing antiviral agents for the treatment of HIV-infected patients. To identify novel PR inhibitors, a label-free, high-throughput mass spectrometry (HTMS) assay was developed using the RapidFire platform and applied as an orthogonal assay to confirm hits identified in a fluorescence resonance energy transfer (FRET)-based primary screen of > 1 million compounds. For substrate selection, a panel of peptide substrates derived from natural processing sites for PR was evaluated on the RapidFire platform. As a result, KVSLNFPIL, a new substrate measured to have a ~ 20- and 60-fold improvement in k cat/K m over the frequently used sequences SQNYPIVQ and SQNYPIV, respectively, was identified for the HTMS screen. About 17% of hits from the FRET-based primary screen were confirmed in the HTMS confirmatory assay including all 304 known PR inhibitors in the set, demonstrating that the HTMS assay is effective at triaging false-positives while capturing true hits. Hence, with a sampling rate of ~7 s per well, the RapidFire HTMS assay enables the high-throughput evaluation of peptide substrates and functions as an efficient tool for hits triage in the discovery of novel PR inhibitors. © 2015 Society for Laboratory Automation and Screening.

  15. Comparison of a conventional and nested PCR for diagnostic confirmation and genotyping of Orientia tsutsugamushi.

    Science.gov (United States)

    Janardhanan, Jeshina; Prakash, John Antony Jude; Abraham, Ooriapadickal C; Varghese, George M

    2014-05-01

    A nested polymerase chain reaction (PCR) targeting the 56-kDa antigen gene is currently the most commonly used molecular technique for confirmation of scrub typhus and genotyping of Orientia tsutsugamushi. In this study, we have compared the commonly used nested PCR (N-PCR) with a single-step conventional PCR (C-PCR) for amplification and genotyping. Eschar samples collected from 24 patients with scrub typhus confirmed by IgM enzyme-linked immunosorbent assay were used for DNA extraction following which amplifications were carried out using nested and C-PCR methods. The amplicons were sequenced and compared to other sequences in the database using BLAST. Conventional PCR showed a high positivity rate of 95.8% compared to the 75% observed using N-PCR. On sequence analysis, the N-PCR amplified region showed more variation among strains than the C-PCR amplified region. The C-PCR, which is more economical, provided faster and better results compared to N-PCR. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Validity of whole slide images for scoring HER2 chromogenic in situ hybridisation in breast cancer.

    Science.gov (United States)

    Al-Janabi, Shaimaa; Horstman, Anja; van Slooten, Henk-Jan; Kuijpers, Chantal; Lai-A-Fat, Clifton; van Diest, Paul J; Jiwa, Mehdi

    2016-05-09

    Whole slide images (WSIs) have stimulated a paradigm shift from conventional to digital pathology in several applications within pathology. Due to the fact that WSIs have not yet been approved for primary diagnostics, validating their use for different diagnostic purposes is still mandatory. The aim of this study was to test the validity of WSI in assessing human epidermal growth factor receptor 2 (HER2) status in breast cancer specimens using chromogenic in situ hybridisation (CISH). Ninety-six HER2 CISH slides were scored by two observers on a light microscope (400× viewing magnification) and on WSI (40× scanning magnification, one focus plane) with a minimum of 6 weeks washout period. The concordance between digital and microscopic HER2 scores was assessed. Digitally, 93/96 cases could be assessed (96.8%). Microscopic and digital evaluation of HER2 amplification status were concordant in 68/93 cases ((73.1%, 95% CI: 0.639 -0.823), κ 0.588). CISH underscoring was most noticeable in the amplified and equivocal categories while the highest level concordance was seen in cases with a normal copy number. Additionally there was a noticeable tendency to underestimate the average HER2 scores on WSI: lower in 59 and higher in 11 cases. There was no major difference in time spent for microscopic scoring (86.9 s) and digital scoring (81.7 s). There was a reasonable concordance between microscopic scoring and WSI-based scoring of HER2 copy number of CISH slides. Nevertheless, WSIs scanned on a single focal plane are insufficient to assess HER2 gene amplification status by scoring CISH due to the noticeable tendency towards digitally underestimating the number of HER2 spots. Scanning at multiple focus planes may offer better resolution for improved digital CISH spot counting. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  18. Quantification of circulating mature endothelial cells using a whole blood four-color flow cytometric assay.

    Science.gov (United States)

    Jacques, Nathalie; Vimond, Nadege; Conforti, Rosa; Griscelli, Franck; Lecluse, Yann; Laplanche, Agnes; Malka, David; Vielh, Philippe; Farace, Françoise

    2008-09-15

    Circulating endothelial cells (CEC) are currently proposed as a potential biomarker for measuring the impact of anti-angiogenic treatments in cancer. However, the lack of consensus on the appropriate method of CEC measurement has led to conflicting data in cancer patients. A validated assay adapted for evaluating the clinical utility of CEC in large cohorts of patients undergoing anti-angiogenic treatments is needed. We developed a four-color flow cytometric assay to measure CEC as CD31(+), CD146(+), CD45(-), 7-amino-actinomycin-D (7AAD)(-) events in whole blood. The distinctive features of the assay are: (1) staining of 1 ml whole blood, (2) use of a whole blood IgPE control to measure accurately background noise, (3) accumulation of a large number of events (almost 5 10(6)) to ensure statistical analysis, and (4) use of 10 microm fluorescent microbeads to evaluate the event size. Assay reproducibility was determined in duplicate aliquots of samples drawn from 20 metastatic cancer patients. Assay linearity was tested by spiking whole blood with low numbers of HUVEC. Five-color flow cytometric experiments with CD144 were performed to confirm the endothelial origin of the cells. CEC were measured in 20 healthy individuals and 125 patients with metastatic cancer. Reproducibility was good between duplicate aliquots (r(2)=0.948, mean difference between duplicates of 0.86 CEC/ml). Detected HUVEC correlated with spiked HUVEC (r(2)=0.916, mean recovery of 100.3%). Co-staining of CD31, CD146 and CD144 confirmed the endothelial nature of cells identified as CEC. Median CEC levels were 6.5/ml (range, 0-15) in healthy individuals and 15.0/ml (range, 0-179) in patients with metastatic carcinoma (p<0.001). The assay proposed here allows reproducible and sensitive measurement of CEC by flow cytometry and could help evaluate CEC as biomarkers of anti-angiogenic therapies in large cohorts of patients.

  19. New concepts of fluorescent probes for specific detection of DNA sequences: bis-modified oligonucleotides in excimer and exciplex detection.

    Science.gov (United States)

    Gbaj, A; Bichenkova, Ev; Walsh, L; Savage, He; Sardarian, Ar; Etchells, Ll; Gulati, A; Hawisa, S; Douglas, Kt

    2009-12-01

    The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5'-bispyrene and 3'-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5'-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5'-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing.

  20. Soil Baiting, Rapid PCR Assay and Quantitative Real Time PCR to Diagnose Late Blight of Potato in Quarantine Programs

    Directory of Open Access Journals (Sweden)

    Touseef Hussain

    2018-05-01

    Full Text Available Phytophthora infestans (mont de Bary is a pathogen of great concern across the globe, and accurate detection is an important component in responding to the outbreaks of potential disease. Although the molecular diagnostic protocol used in regulatory programs has been evaluated but till date methods implying direct comparison has rarely used. In this study, a known area soil samples from potato fields where light blight appear every year (both A1 and A2 mating type was assayed by soil bait method, PCR assay detection and quantification of the inoculums. Suspected disease symptoms appeared on bait tubers were further confirmed by rapid PCR, inoculums were quantified through Real Time PCR, which confirms presence of P. infestans. These diagnostic methods can be highly correlated with one another. Potato tuber baiting increased the sensitivity of the assay compared with direct extraction of DNA from tuber and soil samples. Our study determines diagnostic sensitivity and specificity of the assays to determine the performance of each method. Overall, molecular techniques based on different types of PCR amplification and Real-time PCR can lead to high throughput, faster and more accurate detection method which can be used in quarantine programmes in potato industry and diagnostic laboratory.

  1. Specific immunoassays confirm association of Mycobacterium avium Subsp. paratuberculosis with type-1 but not type-2 diabetes mellitus.

    Directory of Open Access Journals (Sweden)

    Valentina Rosu

    Full Text Available Mycobacterium avium subspecies paratuberculosis (MAP is a versatile pathogen with a broad host range. Its association with type-1 diabetes mellitus (T1DM has been recently proposed. Rapid identification of infectious agents such as MAP in diabetic patients at the level of clinics might be helpful in deciphering the role of chronic bacterial infection in the development of autoimmune diseases such as T1DM.We describe use of an ELISA method to identify live circulating MAP through the detection of a cell envelope protein, MptD by a specific M13 phage--fMptD. We also used another ELISA format to detect immune response to MptD peptide. Both the methods were tested with blood plasma obtained from T1DM, type-2 diabetes (T2DM patients and non-diabetic controls. Our results demonstrate MptD and fMptD ELISA assays to be accurate and sensitive to detect MAP bacilli in a large fraction (47.3% of T1DM patients as compared to non-diabetic controls (12.6% and those with confirmed T2DM (7.7%. Comparative analysis of ELISA assays performed here with 3 other MAP antigen preparations, namely HbHA, Gsd and whole cell MAP lysates confirmed comparable sensitivity of the MptD peptide and the fMptD based ELISA assays. Moreover, we were successful in demonstrating positive bacterial culture in two of the clinical specimen derived from T1DM patients.The MptD peptide/fMptD based ELISA or similar tests could be suggested as rapid and specific field level diagnostic tests for the identification of MAP in diabetic patients and for finding the explanations towards the occurrence of type-1 or type-2 diabetes in the light of an active infectious trigger.

  2. 75 FR 59611 - Microbiology Devices; Reclassification of Herpes Simplex Virus Types 1 and 2 Serological Assays...

    Science.gov (United States)

    2010-09-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2009-N-0344] Microbiology Devices; Reclassification of Herpes Simplex Virus Types 1 and 2 Serological Assays; Confirmation of Effective Date AGENCY: Food and Drug Administration, HHS. ACTION: Direct...

  3. Regulation of gene expression by low levels of ultraviolet-B radiation in Pisum sativum: Isolation of novel genes by suppression subtractive hybridisation

    International Nuclear Information System (INIS)

    Sävenstrand, H.; Brosché, M.; Strid, A.

    2002-01-01

    Suppression subtractive hybridisation was used to isolate genes differentially regulated by low levels (UV-B BE,300 0.13 W m -2 ) of ultraviolet-B radiation (UV-B; 290–320 nm) in Pisum sativum. Six genes were regulated, two of which were novel. The mRNA levels for these two (PsTSDC and PsUOS1) were increased and depressed by UV-B treatment, respectively. Domains in the PsTSDC translation product was similar to TIR (Toll-Interleukin-1 receptor-similar) domains and a NB-ARC domain (nucleotide-binding domain in APAF-1, R gene products and CED-4). The PsUOS1 translation product was similar to an open reading frame in Arabidopsis. Genes encoding embryo-abundant protein (PsEMB) and S-adenosyl-l-methionine synthase (PsSAMS) were induced by UV-B, whereas the transcript levels for genes encoding sucrose transport protein (PsSUT) or ribulose-5-phosphate 3-epimerase (PsR5P3E) were decreased. These regulation patterns are novel, and the PsEMB and PsR5P3E sequences are reported for the first time. The stress-specificity of regulation of these genes were tested by ozone fumigation (100 ppb O 3 ). Qualitatively, the similarity of expression after both UV-B and ozone exposure suggests that, for these genes, similar stress-response pathways are in action. (author)

  4. Analytical and clinical performance of the CDC real time RT-PCR assay for detection and typing of dengue virus.

    Science.gov (United States)

    Santiago, Gilberto A; Vergne, Edgardo; Quiles, Yashira; Cosme, Joan; Vazquez, Jesus; Medina, Juan F; Medina, Freddy; Colón, Candimar; Margolis, Harold; Muñoz-Jordán, Jorge L

    2013-01-01

    Dengue is an acute illness caused by the positive-strand RNA dengue virus (DENV). There are four genetically distinct DENVs (DENV-1-4) that cause disease in tropical and subtropical countries. Most patients are viremic when they present with symptoms; therefore, RT-PCR has been increasingly used in dengue diagnosis. The CDC DENV-1-4 RT-PCR Assay has been developed as an in-vitro diagnostic platform and was recently approved by the US Food and Drug Administration (FDA) for detection of dengue in patients with signs or symptoms of mild or severe dengue. The primers and probes of this test have been designed to detect currently circulating strains of DENV-1-4 from around the world at comparable sensitivity. In a retrospective study with 102 dengue cases confirmed by IgM anti-DENV seroconversion in the convalescent sample, the RT-PCR Assay detected DENV RNA in 98.04% of the paired acute samples. Using sequencing as a positive indicator, the RT-PCR Assay had a 97.92% positive agreement in 86 suspected dengue patients with a single acute serum sample. After extensive validations, the RT-PCR Assay performance was highly reproducible when evaluated across three independent testing sites, did not produce false positive results for etiologic agents of other febrile illnesses, and was not affected by pathological levels of potentially interfering biomolecules. These results indicate that the CDC DENV-1-4 RT-PCR Assay provides a reliable diagnostic platform capable for confirming dengue in suspected cases.

  5. Open innovation for phenotypic drug discovery: The PD2 assay panel.

    Science.gov (United States)

    Lee, Jonathan A; Chu, Shaoyou; Willard, Francis S; Cox, Karen L; Sells Galvin, Rachelle J; Peery, Robert B; Oliver, Sarah E; Oler, Jennifer; Meredith, Tamika D; Heidler, Steven A; Gough, Wendy H; Husain, Saba; Palkowitz, Alan D; Moxham, Christopher M

    2011-07-01

    Phenotypic lead generation strategies seek to identify compounds that modulate complex, physiologically relevant systems, an approach that is complementary to traditional, target-directed strategies. Unlike gene-specific assays, phenotypic assays interrogate multiple molecular targets and signaling pathways in a target "agnostic" fashion, which may reveal novel functions for well-studied proteins and discover new pathways of therapeutic value. Significantly, existing compound libraries may not have sufficient chemical diversity to fully leverage a phenotypic strategy. To address this issue, Eli Lilly and Company launched the Phenotypic Drug Discovery Initiative (PD(2)), a model of open innovation whereby external research groups can submit compounds for testing in a panel of Lilly phenotypic assays. This communication describes the statistical validation, operations, and initial screening results from the first PD(2) assay panel. Analysis of PD(2) submissions indicates that chemical diversity from open source collaborations complements internal sources. Screening results for the first 4691 compounds submitted to PD(2) have confirmed hit rates from 1.6% to 10%, with the majority of active compounds exhibiting acceptable potency and selectivity. Phenotypic lead generation strategies, in conjunction with novel chemical diversity obtained via open-source initiatives such as PD(2), may provide a means to identify compounds that modulate biology by novel mechanisms and expand the innovation potential of drug discovery.

  6. Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

    Science.gov (United States)

    Souberbielle, Jean-Claude; Fayol, Véronique; Sault, Corinne; Lawson-Body, Ethel; Kahan, André; Cormier, Catherine

    2005-02-01

    The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. We studied 228 osteoporotic patients, 927 healthy individuals, 38 patients with primary hyperparathyroidism, and 167 hemodialyzed patients. Serum PTH was measured with the Allegro and the LIAISON assays, and 25OHD was measured with DiaSorin RIA and the LIAISON assay. Regression analysis was used to calculate decision thresholds for the LIAISON assays that were equivalent to those of the Allegro PTH and DiaSorin 25OHD assays. The 25OHD concentrations obtained with the LIAISON assay and the RIA in osteoporotic patients were well correlated (r = 0.83; P 50 nmol/L as eligible for the reference population for the LIAISON PTH assay. In this group, the 3rd-97th percentile interval for LIAISON PTH was 3-51 ng/L. Considering upper reference limits of 46 and 51 ng/L for the Allegro and LIAISON assays, respectively, the frequency of above-normal PTH concentrations in patients with primary hyperparathyroidism was similar in both assays. Regression analysis between serum PTH measured by the Allegro and LIAISON assays in 167 hemodialyzed patients and the corresponding Bland-Altman analysis of these data suggest that the LIAISON PTH assay tends to read higher than the Allegro assay at low concentrations but lower at high concentrations (>300 ng/L). Because clinical decision limits for both PTH and 25OHD should be assay specific, we propose equivalences between these assays and two manual assays used worldwide. These assay-specific decision limits should help potential users of the LIAISON PTH and 25OHD assays.

  7. Multiparametric comparison of chromogenic-based culture methods used to assess the microbiological quality of drinking water and the mFC method combined with a molecular confirmation procedure.

    Science.gov (United States)

    Maheux, Andrée F; Dion-Dupont, Vanessa; Bisson, Marc-Antoine; Bouchard, Sébastien; Jubinville, Éric; Nkuranga, Martine; Rodrigue, Lynda; Bergeron, Michel G; Rodriguez, Manuel J

    2015-03-01

    MI agar and Colilert(®), as well as mFC agar combined with an Escherichia coli-specific molecular assay (mFC + E. coli rtPCR), were compared in terms of their sensitivity, ease of use, time to result and affordability. The three methods yielded a positive E. coli signal for 11.5, 10.8, and 11.5% of the 968 well water samples tested, respectively. One hundred and thirty-six (136) samples gave blue colonies on mFC agar and required confirmation. E. coli-specific rtPCR showed false-positive results in 23.5% (32/136) of cases. In terms of ease of use, Colilert was the simplest method to use while the MI method provided ease of use comparable to all membrane filtration methods. However, the mFC + E. coli rtPCR assay required highly trained employees for confirmation purposes. In terms of affordability, and considering contamination rate of well water samples tested, the Colilert method and the mFC + E. coli rtPCR assay were at least five times more costly than the MI agar method. Overall, compared with the other two methods tested, the MI agar method offers the most advantages to assess drinking water quality.

  8. Development of an integrated assay facility

    International Nuclear Information System (INIS)

    Molesworth, T.V.; Bailey, M.; Findlay, D.J.S.; Sene, M.R.; Swinhoe, M.T.

    1990-01-01

    Initial results of active neutron and active gamma-ray interrogation of a 500 liter cemented simulated CAGR intermediate level radioactive waste drum are described. The basis of the interrogation systems was the Harwell electron linear accelerator HELIOS, which was used to produce the interrogating neutrons and gamma-rays. Several sets of neutron detectors were located around the drum to count signature neutrons. The responses of the system were measured by placing known samples at many different locations within the drum. In general, measured responses confirmed calculated responses. Good agreement was obtained for the azimuthal angle dependences. The absolute responses agreed well for gamma-ray interrogation, but the calculations were apparently over-estimates for neutron interrogation. Those aspects requiring consideration in the practical application of assay techniques are identified. 8 refs., 6 figs

  9. Plutonian Moon confirmed

    Science.gov (United States)

    In late February, two separate observations confirmed the 1978 discovery by U.S. Naval Observatory scientist James W. Christy of a moon orbiting the planet Pluto. According to the U.S. Naval Observatory, these two observations were needed before the International Astronomical Society (IAS) would officially recognize the discovery.Two types of observations of the moon, which was named Charon after the ferryman in Greek mythology who carried the dead to Pluto's realm, were needed for confirmation: a transit, in which the moon passes in front of Pluto, and an occultation, in which the moon passes behind the planet. These two phenomena occur only during an 8-year period every 124 years that had been calculated to take place during 1984-1985. Both events were observed in late February.

  10. Effects of estradiol and progesterone on the variability of the micronucleus assay

    International Nuclear Information System (INIS)

    Baeyens, Ans; Vandersickel, Veerle; Thierens, Hubert; Ridder, Leo De; Vral, Anne

    2005-01-01

    To investigate chromosomal radiosensitivity of lymphocytes the micronucleus (MN) assay has been used for many years. The results of these studies suggest the use of the MN assay as a biomarker for cancer predisposition. However, the MN assay has still some limitations associated with the reproducibility and sensitivity. Especially a high intra-individual variability has been observed. An explanation for this high intra-individual variability is not yet available. In literature it is suggested that the high variability among females is attributable to hormonal status. In this study we investigated if the high intra-individual variability in micronucleus formation in lymphocytes of females after in vitro exposure to ionising radiation is caused by variations in hormone levels of estradiol (E2) and progesterone (PROG). For this, the MN assay was performed on blood samples of 18 healthy women during 7 consecutive weeks while the estradiol and progesterone levels were determined at the same time. The MN assay was also examined in cultures of isolated blood lymphocytes with estradiol or progesterone levels added in vitro. The results demonstrated that estradiol and progesterone levels have no influence on the variations in radiation-induced MN yields observed in blood samples of healthy women. These conclusions were confirmed by the 'in vitro' experiments as no correlation between the MN yields and the concentrations of hormones (estradiol or progesterone) added in vitro to isolated lymphocytes cultures was observed

  11. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.

    Science.gov (United States)

    Worlock, A; Blair, D; Hunsicker, M; Le-Nguyen, T; Motta, C; Nguyen, C; Papachristou, E; Pham, J; Williams, A; Vi, M; Vinluan, B; Hatzakis, A

    2017-04-04

    The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low

  12. Nondestructive Assay Data Integration with the SKB-50 Assemblies - FY16 Update

    International Nuclear Information System (INIS)

    Tobin, Stephen Joseph; Fugate, Michael Lynn; Trellue, Holly Renee; DeBaere, Paul; Sjoland, Anders; Liljenfeldt, Henrik; Hu, Jianwei; Backstrom, Ulrika; Bengtsson, Martin; Burr, Tomas; Eliasson, Annika; Favalli, Andrea; Gauld, Ian; Grogan, Brandon; Jansson, Peter; Junell, Henrik; Schwalbach, Peter; Vaccaro, Stefano; Vo, Duc Ta; Wildestrand, Henrik

    2016-01-01

    A project to research the application of non-destructive assay (NDA) techniques for spent fuel assemblies is underway at the Central Interim Storage Facility for Spent Nuclear Fuel (for which the Swedish acronym is Clab) in Oskarshamn, Sweden. The research goals of this project contain both safeguards and non-safeguards interests. These nondestructive assay (NDA) technologies are designed to strengthen the technical toolkit of safeguard inspectors and others to determine the following technical goals more accurately; Verify initial enrichment, burnup, and cooling time of facility declaration for spent fuel assemblies; Detect replaced or missing pins from a given spent fuel assembly to confirm its integrity; and Estimate plutonium mass and related plutonium and uranium fissile mass parameters in spent fuel assemblies. Estimate heat content, and measure reactivity (multiplication).

  13. Nondestructive Assay Data Integration with the SKB-50 Assemblies - FY16 Update

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, Stephen Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fugate, Michael Lynn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Trellue, Holly Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); DeBaere, Paul [DG Energy, Luxembourg (Germany); Sjoland, Anders [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Liljenfeldt, Henrik [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hu, Jianwei [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Backstrom, Ulrika [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden); Bengtsson, Martin [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden); Burr, Tomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); International Atomic Energy Agency, Vienna (Austria); Eliasson, Annika [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Favalli, Andrea [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gauld, Ian [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Grogan, Brandon [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jansson, Peter [Uppsala Univ. (Sweden); Junell, Henrik [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Schwalbach, Peter [DG Energy, Luxembourg (Germany); Vaccaro, Stefano [DG Energy, Luxembourg (Germany); Vo, Duc Ta [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wildestrand, Henrik [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Vattenfall AB, Stockholm (Sweden)

    2016-10-28

    A project to research the application of non-destructive assay (NDA) techniques for spent fuel assemblies is underway at the Central Interim Storage Facility for Spent Nuclear Fuel (for which the Swedish acronym is Clab) in Oskarshamn, Sweden. The research goals of this project contain both safeguards and non-safeguards interests. These nondestructive assay (NDA) technologies are designed to strengthen the technical toolkit of safeguard inspectors and others to determine the following technical goals more accurately; Verify initial enrichment, burnup, and cooling time of facility declaration for spent fuel assemblies; Detect replaced or missing pins from a given spent fuel assembly to confirm its integrity; and Estimate plutonium mass and related plutonium and uranium fissile mass parameters in spent fuel assemblies. Estimate heat content, and measure reactivity (multiplication).

  14. The identification of carbapenemase types in Enterobacteriaceae by using molecular assay and phenotyping confirmation tests.

    Science.gov (United States)

    Genc, Ozlem; Aksu, Evrim; Gulcan, Aynur

    2016-06-01

    In this study, we aimed to identify the molecular carbapenemase types of the Enterobacteriaceae isolates and to evaluate the performance of manually prepared and commercially available combination disc methods and the modified Hodge test. One hundred and forty carbapenemase producing isolates and 45 isolates as control group were included in our study. The Xpert CARBA-R test was used as the molecular method. Antibiotic susceptibility tests were performed using combined discs, manually prepared with APBA (3-aminophenyl boronic acid), DPA (dipicolinic acid), EDTA (Ethylene diamine tetra acetic acid), cloxacillin supplements and Mastdiscs Combi-D70C that includes four antibiotic discs with specific inhibitors and temocillin discs. The modified Hodge test was performed on all isolates. OXA-48 gene was identified in 129 isolates , the NDM gene was identified in 10 isolates and VIM in one isolate. Thirty inaccurate results (30/185, 16%) were detected by using the manually prepared confirmation test. The sensitivity and specificity of this test were identified respectively 85% and 73%. Also, the sensitivity and specificity of the Mastdiscs Combi-D70C were identified as 100%. Negative results were detected in 3 NDM isolates with the use of a modified Hodge test. Sensitivity and specificity were calculated for the modified Hodge test respectively 97% and 100%. Finally, molecular methods provide results rapidly but they are not always easily accessible. The modified Hodge test can be used only for screening as a first step test and is not one of the tests that can identify the type of the carbapenemase. When carbapenem-resistant Enterobacteriaceae are detected, a commercial kit like Mastdiscs Combi-D70 may be preferred instead of the manually prepared phenotypic verification tests. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Flow cytometric immunobead assay for quantitative detection of platelet autoantibodies in immune thrombocytopenia patients.

    Science.gov (United States)

    Zhai, Juping; Ding, Mengyuan; Yang, Tianjie; Zuo, Bin; Weng, Zhen; Zhao, Yunxiao; He, Jun; Wu, Qingyu; Ruan, Changgeng; He, Yang

    2017-10-23

    Platelet autoantibody detection is critical for immune thrombocytopenia (ITP) diagnosis and prognosis. Therefore, we aimed to establish a quantitative flow cytometric immunobead assay (FCIA) for ITP platelet autoantibodies evaluation. Capture microbeads coupled with anti-GPIX, -GPIb, -GPIIb, -GPIIIa and P-selectin antibodies were used to bind the platelet-bound autoantibodies complex generated from plasma samples of 250 ITP patients, 163 non-ITP patients and 243 healthy controls, a fluorescein isothiocyanate (FITC)-conjugated secondary antibody was the detector reagent and mean fluorescence intensity (MFI) signals were recorded by flow cytometry. Intra- and inter-assay variations of the quantitative FCIA assay were assessed. Comparisons of the specificity, sensitivity and accuracy between quantitative and qualitative FCIA or monoclonal antibody immobilization of platelet antigen (MAIPA) assay were performed. Finally, treatment process was monitored by our quantitative FCIA in 8 newly diagnosed ITPs. The coefficient of variations (CV) of the quantitative FCIA assay were respectively 9.4, 3.8, 5.4, 5.1 and 5.8% for anti-GPIX, -GPIb, -GPIIIa, -GPIIb and -P-selectin autoantibodies. Elevated levels of autoantibodies against platelet glycoproteins GPIX, GPIb, GPIIIa, GPIIb and P-selectin were detected by our quantitative FCIA in ITP patients compared to non-ITP patients or healthy controls. The sensitivity, specificity and accuracy of our quantitative assay were respectively 73.13, 81.98 and 78.65% when combining all 5 autoantibodies, while the sensitivity, specificity and accuracy of MAIPA assay were respectively 41.46, 90.41 and 72.81%. A quantitative FCIA assay was established. Reduced levels of platelet autoantibodies could be confirmed by our quantitative FCIA in ITP patients after corticosteroid treatment. Our quantitative assay is not only good for ITP diagnosis but also for ITP treatment monitoring.

  16. Analytical and clinical performance of the CDC real time RT-PCR assay for detection and typing of dengue virus.

    Directory of Open Access Journals (Sweden)

    Gilberto A Santiago

    Full Text Available Dengue is an acute illness caused by the positive-strand RNA dengue virus (DENV. There are four genetically distinct DENVs (DENV-1-4 that cause disease in tropical and subtropical countries. Most patients are viremic when they present with symptoms; therefore, RT-PCR has been increasingly used in dengue diagnosis. The CDC DENV-1-4 RT-PCR Assay has been developed as an in-vitro diagnostic platform and was recently approved by the US Food and Drug Administration (FDA for detection of dengue in patients with signs or symptoms of mild or severe dengue. The primers and probes of this test have been designed to detect currently circulating strains of DENV-1-4 from around the world at comparable sensitivity. In a retrospective study with 102 dengue cases confirmed by IgM anti-DENV seroconversion in the convalescent sample, the RT-PCR Assay detected DENV RNA in 98.04% of the paired acute samples. Using sequencing as a positive indicator, the RT-PCR Assay had a 97.92% positive agreement in 86 suspected dengue patients with a single acute serum sample. After extensive validations, the RT-PCR Assay performance was highly reproducible when evaluated across three independent testing sites, did not produce false positive results for etiologic agents of other febrile illnesses, and was not affected by pathological levels of potentially interfering biomolecules. These results indicate that the CDC DENV-1-4 RT-PCR Assay provides a reliable diagnostic platform capable for confirming dengue in suspected cases.

  17. A Functional Henipavirus Envelope Glycoprotein Pseudotyped Lentivirus Assay System

    Directory of Open Access Journals (Sweden)

    Broder Christopher C

    2010-11-01

    Full Text Available Abstract Background Hendra virus (HeV and Nipah virus (NiV are newly emerged zoonotic paramyxoviruses discovered during outbreaks in Queensland, Australia in 1994 and peninsular Malaysia in 1998/9 respectively and classified within the new Henipavirus genus. Both viruses can infect a broad range of mammalian species causing severe and often-lethal disease in humans and animals, and repeated outbreaks continue to occur. Extensive laboratory studies on the host cell infection stage of HeV and NiV and the roles of their envelope glycoproteins have been hampered by their highly pathogenic nature and restriction to biosafety level-4 (BSL-4 containment. To circumvent this problem, we have developed a henipavirus envelope glycoprotein pseudotyped lentivirus assay system using either a luciferase gene or green fluorescent protein (GFP gene encoding human immunodeficiency virus type-1 (HIV-1 genome in conjunction with the HeV and NiV fusion (F and attachment (G glycoproteins. Results Functional retrovirus particles pseudotyped with henipavirus F and G glycoproteins displayed proper target cell tropism and entry and infection was dependent on the presence of the HeV and NiV receptors ephrinB2 or B3 on target cells. The functional specificity of the assay was confirmed by the lack of reporter-gene signals when particles bearing either only the F or only G glycoprotein were prepared and assayed. Virus entry could be specifically blocked when infection was carried out in the presence of a fusion inhibiting C-terminal heptad (HR-2 peptide, a well-characterized, cross-reactive, neutralizing human mAb specific for the henipavirus G glycoprotein, and soluble ephrinB2 and B3 receptors. In addition, the utility of the assay was also demonstrated by an examination of the influence of the cytoplasmic tail of F in its fusion activity and incorporation into pseudotyped virus particles by generating and testing a panel of truncation mutants of NiV and HeV F

  18. Assay strategies and methods for phospholipases

    International Nuclear Information System (INIS)

    Reynolds, L.J.; Washburn, W.N.; Deems, R.A.; Dennis, E.A.

    1991-01-01

    Of the general considerations discussed, the two issues which are most important in choosing an assay are (1) what sensitivity is required to assay a particular enzyme and (2) whether the assay must be continuous. One can narrow the options further by considering substrate availability, enzyme specificity, assay convenience, or the presence of incompatible side reactions. In addition, the specific preference of a particular phospholipase for polar head group, micellar versus vesicular substrates, and anionic versus nonionic detergents may further restrict the options. Of the many assays described in this chapter, several have limited applicability or serious drawbacks and are not commonly employed. The most commonly used phospholipase assays are the radioactive TLC assay and the pH-stat assay. The TLC assay is probably the most accurate, sensitive assay available. These aspects often outweigh the disadvantages of being discontinuous, tedious, and expensive. The radioactive E. coli assay has become popular recently as an alternative to the TLC assay for the purification of the mammalian nonpancreatic phospholipases. The assay is less time consuming and less expensive than the TLC assay, but it is not appropriate when careful kinetics are required. Where less sensitivity is needed, or when a continuous assay is necessary, the pH-stat assay is often employed. With purified enzymes, when free thiol groups are not present, a spectrophotometric thiol assay can be used. This assay is ∼ as sensitive as the pH-stat assay but is more convenient and more reproducible, although the substrate is not available commercially. Despite the many assay choices available, the search continues for a convenient, generally applicable assay that is both sensitive and continuous

  19. An Internalin A Probe-Based Genosensor for Listeria monocytogenes Detection and Differentiation

    Directory of Open Access Journals (Sweden)

    Laura Bifulco

    2013-01-01

    Full Text Available Internalin A (InlA, a protein required for Listeria monocytogenes virulence, is encoded by the inlA gene, which is only found in pathogenic strains of this genus. One of the best ways to detect and confirm the pathogenicity of the strain is the detection of one of the virulence factors produced by the microorganism. This paper focuses on the design of an electrochemical genosensor used to detect the inlA gene in Listeria strains without labelling the target DNA. The electrochemical sensor was obtained by immobilising an inlA gene probe (single-stranded oligonucleotide on the surfaces of screen-printed gold electrodes (Au-SPEs by means of a mercaptan-activated self-assembled monolayer (SAM. The hybridisation reaction occurring on the electrode surface was electrochemically transduced by differential pulse voltammetry (DPV using methylene blue (MB as an indicator. The covalently immobilised single-stranded DNA was able to selectively hybridise to its complementary DNA sequences in solution to form double-stranded DNA on the gold surface. A significant decrease of the peak current of the voltammogram (DPV upon hybridisation of immobilised ssDNA was recorded. Whole DNA samples of L. monocytogenes strains could be discriminated from other nonpathogenic Listeria species DNA with the inlA gene DNA probe genosensor.

  20. Validation of an immunodiagnostic assay for detection of 13 Streptococcus pneumoniae serotype-specific polysaccharides in human urine.

    Science.gov (United States)

    Pride, Michael W; Huijts, Susanne M; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C; Bonten, Marc J M; Jansen, Kathrin U

    2012-08-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults.

  1. SYBR green-based one step quantitative real-time polymerase chain reaction assay for the detection of Zika virus in field-caught mosquitoes.

    Science.gov (United States)

    Tien, Wei-Ping; Lim, Gareth; Yeo, Gladys; Chiang, Suzanna Nicole; Chong, Chee-Seng; Ng, Lee-Ching; Hapuarachchi, Hapuarachchige Chanditha

    2017-09-19

    The monitoring of vectors is one of the key surveillance measures to assess the risk of arbovirus transmission and the success of control strategies in endemic regions. The recent re-emergence of Zika virus (ZIKV) in the tropics, including Singapore, emphasizes the need to develop cost-effective, rapid and accurate assays to monitor the virus spread by mosquitoes. As ZIKV infections largely remain asymptomatic, early detection of ZIKV in the field-caught mosquitoes enables timely implementation of appropriate mosquito control measures. We developed a rapid, sensitive and specific real-time reverse transcription polymerase chain reaction (rRT-PCR) assay for the detection of ZIKV in field-caught mosquitoes. The primers and PCR cycling conditions were optimized to minimize non-specific amplification due to cross-reactivity with the genomic material of Aedes aegypti, Aedes albopictus, Culex quinquefasciatus, Culex tritaeniorhynchus, Culex sitiens and Anopheles sinensis, as well as accompanying microbiota. The performance of the assay was further evaluated with a panel of flaviviruses and alphaviruses as well as in field-caught Ae. aegypti mosquitoes confirmed to be positive for ZIKV. As compared to a probe-based assay, the newly developed assay demonstrated 100% specificity and comparable detection sensitivity for ZIKV in mosquitoes. Being a SYBR Green-based method, the newly-developed assay is cost-effective and easy to adapt, thus is applicable to large-scale vector surveillance activities in endemic countries, including those with limited resources and expertise. The amplicon size (119 bp) also allows sequencing to confirm the virus type. The primers flank relatively conserved regions of ZIKV genome, so that, the assay is able to detect genetically diverse ZIKV strains. Our findings, therefore, testify the potential use of the newly-developed assay in vector surveillance programmes for ZIKV in endemic regions.

  2. International network for comparison of HIV neutralization assays: the NeutNet report II.

    Directory of Open Access Journals (Sweden)

    Leo Heyndrickx

    Full Text Available BACKGROUND: Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s can provide measures of protective immunity. An international collaboration (NeutNet involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs and soluble CD4 (Phase I study. METHODS: In the present study (Phase II, polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs (Virus Infectivity Assays, VIA, or Env (gp160-pseudotyped viruses (pseudoviruses, PSV produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP reporter gene expression. FINDINGS: Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014. Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. CONCLUSIONS: Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus

  3. International network for comparison of HIV neutralization assays: the NeutNet report II.

    Science.gov (United States)

    Heyndrickx, Leo; Heath, Alan; Sheik-Khalil, Enas; Alcami, Jose; Bongertz, Vera; Jansson, Marianne; Malnati, Mauro; Montefiori, David; Moog, Christiane; Morris, Lynn; Osmanov, Saladin; Polonis, Victoria; Ramaswamy, Meghna; Sattentau, Quentin; Tolazzi, Monica; Schuitemaker, Hanneke; Willems, Betty; Wrin, Terri; Fenyö, Eva Maria; Scarlatti, Gabriella

    2012-01-01

    Neutralizing antibodies provide markers for vaccine-induced protective immunity in many viral infections. By analogy, HIV-1 neutralizing antibodies induced by immunization may well predict vaccine effectiveness. Assessment of neutralizing antibodies is therefore of primary importance, but is hampered by the fact that we do not know which assay(s) can provide measures of protective immunity. An international collaboration (NeutNet) involving 18 different laboratories previously compared different assays using monoclonal antibodies (mAbs) and soluble CD4 (Phase I study). In the present study (Phase II), polyclonal reagents were evaluated by 13 laboratories. Each laboratory evaluated nine plasmas against an 8 virus panel representing different genetic subtypes and phenotypes. TriMab, a mixture of three mAbs, was used as a positive control allowing comparison of the results with Phase I in a total of nine different assays. The assays used either uncloned virus produced in peripheral blood mononuclear cells (PBMCs) (Virus Infectivity Assays, VIA), or Env (gp160)-pseudotyped viruses (pseudoviruses, PSV) produced in HEK293T cells from molecular clones or from uncloned virus. Target cells included PBMC and genetically engineered cell lines in either single- or multiple-cycle infection format. Infection was quantified by using a range of assay read-outs including extra- or intra-cellular p24 antigen detection, luciferase, beta-galactosidase or green fluorescent protein (GFP) reporter gene expression. Using TriMab, results of Phase I and Phase II were generally in agreement for six of the eight viruses tested and confirmed that the PSV assay is more sensitive than PBMC (p = 0.014). Comparisons with the polyclonal reagents showed that sensitivities were dependent on both virus and plasma. Here we further demonstrate clear differences in assay sensitivities that were dependent on both the neutralizing reagent and the virus. Consistent with the Phase I study, we recommend

  4. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  5. Successful Application of the Gamma-Interferon Assay in a Bovine Tuberculosis Eradication Program: The French Bullfighting Herd Experience.

    Science.gov (United States)

    Keck, Nicolas; Boschiroli, Maria-Laura; Smyej, Florence; Vogler, Valérie; Moyen, Jean-Louis; Desvaux, Stéphanie

    2018-01-01

    In the French Camargue region, where bovine tuberculosis had been enzootic for several years in bullfighting cattle herds, the gamma-interferon (IFN) assay was used since 2003 in parallel with the intradermal test in order to increase overall disease detection sensitivity in infected herds. This study presents the results of a field-evaluation of the assay during a 10-year period (2004-2014) of disease control and surveillance program and explores the particular pattern of IFN assay results in bullfight herds in comparison to cattle from other regions of France. The low sensitivity [59.2% (50.6; 67.3)] of IFN assay using the tuberculin stimulation could be related to the poor gamma-IFN production from bullfight cattle blood cells which is significantly lower than in animals of conventional breeds. The characteristics of the assay were progressively adapted to the epidemiological situation and the desired strategic applications. Data analysis with a receiver operating characteristic curve based on a simple S/P value algorithm allowed for the determination of a new cutoff adapted for a global screening, giving a high specificity of 99.9% results and a high accuracy of the assay. Having regularly risen to above 5% since 2005, with a peak around 10% in 2010, the annual incidence dropped to under 1% in 2014. The positive predictive value relative to the bacteriological confirmation evolved during the years, from 33% in 2009 to 12% during the last screening period, a normal trend in a context of decreasing prevalence. The estimated rate of false-positive reactions during screening campaigns was 0.67%, confirming the high specificity of the test, measured in bTB negative herds, in this epidemiological context. The proportion of false-positive reactions decreased with the age and was higher in males than in females. Although these results indicate that the IFN assay is accurate in the field, it also emphasizes great differences between interferon quantities produced by

  6. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Timothy M. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Lambert, Iain B. [Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Williams, Andrew [Biostatistics and Epidemiology Division, Safe Environments Programme, 6604B, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Douglas, George R. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Yauk, Carole L. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada)]. E-mail: carole_yauk@hc-sc.gc.ca

    2006-06-25

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development.

  7. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    International Nuclear Information System (INIS)

    Singer, Timothy M.; Lambert, Iain B.; Williams, Andrew; Douglas, George R.; Yauk, Carole L.

    2006-01-01

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development

  8. Multiplex PCR assay for simultaneous detection of six major bacterial pathogens of rice.

    Science.gov (United States)

    Cui, Z; Ojaghian, M R; Tao, Z; Kakar, K U; Zeng, J; Zhao, W; Duan, Y; Vera Cruz, C M; Li, B; Zhu, B; Xie, G

    2016-05-01

    The aim of this study was to develop a multiplex PCR (mPCR) assay for rapid, sensitive and simultaneous detection of six important rice pathogens: Xanthomonas oryzae pv. oryzae, X. oryzae pv. oryzicola, Pseudomonas fuscovaginae, Burkholderia glumae, Burkholderia gladioli and Acidovorax avenae subsp. avenae. Specific primers were designed through a bioinformatics pipeline. Sensitivity of detection was established using both traditional PCR and quantitative real-time PCR on isolated DNA and on bacterial cells both in vitro and in simulated diseased seeds and the parameters were optimized for an mPCR assay. A total of 150 bacterial strains were tested for specificity. The mPCR assay accurately predicted the presence of pathogens among 44 symptomatic and asymptomatic rice seed, sheath and leaf samples. This study confirmed that this mPCR assay is a rapid, reliable and simple tool for the simultaneous detection of six important rice bacterial pathogens. This study is the first report of a method allowing simultaneous detection of six major rice pathogens. The ability to use crude extracts from plants without bacterial isolation or DNA extraction enhances the value of this mPCR technology for rapid detection and aetiological/epidemiological studies. © 2016 The Society for Applied Microbiology.

  9. Clinical Evaluation of Fully Automated Elecsys® Syphilis Assay for the Detection of Antibodies of Treponema pallidum.

    Science.gov (United States)

    Li, Dongdong; An, Jingna; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2016-11-01

    The resurgence of syphilis in recent years has become a serious threat to the public health worldwide, and the serological detection of specific antibodies against Treponema pallidum (TP) remains the most reliable method for laboratory diagnosis of syphilis. The performance of the Elecsys ® Syphilis assay, a brand new electrochemiluminescene immunoassay (ECLIA), was assessed by large amounts of samples in this study. In comparison with InTec assay, the Elecsys ® Syphilis assay was evaluated in 146 preselected samples from patients with syphilis, 1803 clinical routine samples, and 175 preselected samples from specific populations with reportedly increased rates of false-positive syphilis test results. Discrepancy samples must be investigated by Mikrogen Syphilis recomline assay. There was an overall agreement of 99.58% between two assays (Kappa = 0.975). The sensitivity and specificity of the Elecsys ® Syphilis assay were 100.0% (95% CI, 96.8-100.0%) and 99.8% (95% CI, 99.5-100.0%), respectively. The Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2124 samples enrolled, compared with the InTec assay. Considering the excellent ease of use and automation, high throughput, and its superior sensitivity, especially in primary syphilis, the Elecsys ® Syphilis assay could represent an outstanding choice for screening of syphilis in high-volume laboratories. However, more attention was still needed, or the results must be confirmed by other treponemal immunoassays. The new Elecsys ® Syphilis assay is applied to patients with malignant neoplasm or HIV infection. © 2016 Wiley Periodicals, Inc.

  10. Calibration and Confirmation in Geophysical Models

    Science.gov (United States)

    Werndl, Charlotte

    2016-04-01

    For policy decisions the best geophysical models are needed. To evaluate geophysical models, it is essential that the best available methods for confirmation are used. A hotly debated issue on confirmation in climate science (as well as in philosophy) is the requirement of use-novelty (i.e. that data can only confirm models if they have not already been used before. This talk investigates the issue of use-novelty and double-counting for geophysical models. We will see that the conclusions depend on the framework of confirmation and that it is not clear that use-novelty is a valid requirement and that double-counting is illegitimate.

  11. Development of a Rapid Real-Time PCR Assay for Quantitation of Pneumocystis carinii f. sp. Carinii

    DEFF Research Database (Denmark)

    Larsen, Hans Henrik; Kovacs, Joseph A; Stock, Frida

    2002-01-01

    6 log values for standards containing > or =5 copies/tube. Application of the assay to a series of 10-fold dilutions of P. carinii organisms isolated from rat lung demonstrated that it was reproducibly quantitative over 5 log values (r = 0.99). The assay was applied to a recently reported in vitro...... axenic cultivation system for P. carinii and confirmed our microscopy findings that no organism multiplication had occurred during culture. For all cultures analyzed, QTD PCR assays showed a decrease in P. carinii DNA that exceeded the expected decrease due to dilution of the inoculum upon transfer......A method for reliable quantification of Pneumocystis carinii in research models of P. carinii pneumonia (PCP) that is more convenient and reproducible than microscopic enumeration of organisms would greatly facilitate investigations of this organism. We developed a rapid quantitative touchdown (QTD...

  12. The comet assay in testing the potential genotoxicity of nanomaterials

    Directory of Open Access Journals (Sweden)

    Amaya Azqueta

    2015-06-01

    validation. The comet assay has not been yet proposed as an appropriate test to check the genotoxic potential of NMs, though at a research level it is the most used in vitro assay and the second most used in vivo assay. Moreover, the combination of the comet assay with enzymes that convert altered bases to breaks allows the identification of DNA damage induced by secondary mechanisms (e.g. oxidative stress induced by inflammation, which is very relevant in the case of NMs. Possible problems with the use of the comet assay have been suggested: NMs have been detected in close association with comets, and might interact with the DNA; or NMs might inhibit the action of enzymes. However, control experiments have not confirmed that these interactions are significant.

  13. An Improved Neutral a-Glucosidase Assay for Assessment of Epididymal Function—Validation and Comparison to the WHO Method

    Directory of Open Access Journals (Sweden)

    Frank Eertmans

    2014-01-01

    Full Text Available Neutral a-glucosidase (NAG activity in human seminal plasma is an important indicator for epididymis functionality. In the present study, the classic World Health Organization (WHO method has been adapted to enhance assay robustness. Changes include modified enzyme reaction buffer composition and usage of an alternative enzyme inhibitor for background correction (glucose instead of castanospermine. Both methods have been tested in parallel on 144 semen samples, obtained from 94 patients/donors and 50 vasectomized men (negative control, respectively. Passing-Bablok regression analysis demonstrated equal assay performance. In terms of assay validation, analytical specificity, detection limit, measuring range, precision, and cut-off values have been calculated. These data confirm that the adapted method is a reliable, improved tool for NAG analysis in human semen.

  14. Hormone assay

    International Nuclear Information System (INIS)

    Eisentraut, A.M.

    1977-01-01

    An improved radioimmunoassay is described for measuring total triiodothyronine or total thyroxine levels in a sample of serum containing free endogenous thyroid hormone and endogenous thyroid hormone bound to thyroid hormone binding protein. The thyroid hormone is released from the protein by adding hydrochloric acid to the serum. The pH of the separated thyroid hormone and thyroid hormone binding protein is raised in the absence of a blocking agent without interference from the endogenous protein. 125 I-labelled thyroid hormone and thyroid hormone antibodies are added to the mixture, allowing the labelled and unlabelled thyroid hormone and the thyroid hormone antibody to bind competitively. This results in free thyroid hormone being separated from antibody bound thyroid hormone and thus the unknown quantity of thyroid hormone may be determined. A thyroid hormone test assay kit is described for this radioimmunoassay. It provides a 'single tube' assay which does not require blocking agents for endogenous protein interference nor an external solid phase sorption step for the separation of bound and free hormone after the competitive binding step; it also requires a minimum number of manipulative steps. Examples of the assay are given to illustrate the reproducibility, linearity and specificity of the assay. (UK)

  15. Interspecific in vitro assay for the chimera-forming ability of human pluripotent stem cells.

    Science.gov (United States)

    Masaki, Hideki; Kato-Itoh, Megumi; Umino, Ayumi; Sato, Hideyuki; Hamanaka, Sanae; Kobayashi, Toshihiro; Yamaguchi, Tomoyuki; Nishimura, Ken; Ohtaka, Manami; Nakanishi, Mahito; Nakauchi, Hiromitsu

    2015-09-15

    Functional assay limitations are an emerging issue in characterizing human pluripotent stem cells (PSCs). With rodent PSCs, chimera formation using pre-implantation embryos is the gold-standard assay of pluripotency (competence of progeny to differentiate into all three germ layers). In human PSCs (hPSCs), however, this can only be monitored via teratoma formation or in vitro differentiation, as ethical concerns preclude generation of human-human or human-animal chimeras. To circumvent this issue, we developed a functional assay utilizing interspecific blastocyst injection and in vitro culture (interspecies in vitro chimera assay) that enables the development and observation of embryos up to headfold stage. The assay uses mouse pre-implantation embryos and rat, monkey and human PSCs to create interspecies chimeras cultured in vitro to the early egg-cylinder stage. Intra- and interspecific chimera assays with rodent PSC lines were performed to confirm the consistency of results in vitro and in vivo. The behavior of chimeras developed in vitro appeared to recapitulate that of chimeras developed in vivo; that is, PSC-derived cells survived and were integrated into the epiblast of egg-cylinder-stage embryos. This indicates that the interspecific in vitro chimera assay is useful in evaluating the chimera-forming ability of rodent PSCs. However, when human induced PSCs (both conventional and naïve-like types) were injected into mouse embryos and cultured, some human cells survived but were segregated; unlike epiblast-stage rodent PSCs, they never integrated into the epiblast of egg-cylinder-stage embryos. These data suggest that the mouse-human interspecies in vitro chimera assay does not accurately reflect the early developmental potential/process of hPSCs. The use of evolutionarily more closely related species as host embryos might be necessary to evaluate the developmental potency of hPSCs. © 2015. Published by The Company of Biologists Ltd.

  16. A two-site immunoradiometric assay for human pregnancy-associated plasma protein A (PAPP-A) using monoclonal antibodies

    International Nuclear Information System (INIS)

    Mowles, E.A.; Pinto-Furtado, L.G.; Bolton, A.E.

    1986-01-01

    A rapid, sensitive immunoradiometric assay has been developed for human pregnancy-associated plasma protein A (PAPP-A) using a purified mouse monoclonal antibody as the tracer and a rabbit polyclonal antibody to this protein in the solid-phase antibody preparation. The assay showed no measurable cross-reaction (< 0.1%) against a range of purified human placental proteins, and a good correlation with a previously described radioimmunoassay procedure when tested on samples taken throughout normal human pregnancies. No PAPP-A-like immunological activity could be detected in sera from non-pregnant women, confirming the absence of this protein from the circulation outside pregnancy. (Auth.)

  17. Lectin binding assays for in-process monitoring of sialylation in protein production.

    Science.gov (United States)

    Xu, Weiduan; Chen, Jianmin; Yamasaki, Glenn; Murphy, John E; Mei, Baisong

    2010-07-01

    Many therapeutic proteins require appropriate glycosylation for their biological activities and plasma half life. Coagulation factor VIII (FVIII) is a glycoprotein which has extensive post-translational modification by N-linked glycosylation. The terminal sialic acid in the N-linked glycans of FVIII is required for maximal circulatory half life. The extent of FVIII sialylation can be determined by high pH anion-exchange chromatography coupled with a pulse electrochemical detector (HPAEC-PED), but this requires a large amount of purified protein. Using FVIII as a model, the objective of the present study was to develop assays that enable detection and prediction of sialylation deficiency at an early stage in the process and thus prevent downstream product quality excursions. Lectin ECA (Erythrina Cristagalli) binds to unsialylated Galbeta1-4 GlcNAc and the ECA-binding level (i.e., terminal Gal(beta1-4) exposure) is inversely proportional to the level of sialylation. By using ECA, a cell-based assay was developed to measure the global sialylation profile in FVIII producing cells. To examine the Galbeta1-4 exposure on the FVIII molecule in bioreactor tissue culture fluid (TCF), an ELISA-based ECA-FVIII binding assay was developed. The ECA-binding specificity in both assays was assessed by ECA-specific sugar inhibitors and neuraminidase digestion. The ECA-binding specificity was also independently confirmed by a ST3GAL4 siRNA knockdown experiment. To establish the correlation between Galbeta1-4 exposure and the HPAEC-PED determined FVIII sialylation value, the FVIII containing bioreactor TCF and the purified FVIII samples were tested with ECA ELISA binding assay. The results indicated an inverse correlation between ECA binding and the corresponding HPAEC-PED sialylation value. The ECA-binding assays are cost effective and can be rapidly performed, thereby making them effective for in-process monitoring of protein sialylation.

  18. New Concepts of Fluorescent Probes for Specific Detection of DNA Sequences: Bis-Modified Oligonucleotides in Excimer and Exciplex Detection

    Directory of Open Access Journals (Sweden)

    Gbaj A

    2009-01-01

    Full Text Available The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5’-bispyrene and 3’-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5’-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5'-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing.

  19. Comet Assay on Daphnia magna in eco-genotoxicity testing.

    Science.gov (United States)

    Pellegri, Valerio; Gorbi, Gessica; Buschini, Annamaria

    2014-10-01

    Detection of potentially hazardous compounds in water bodies is a priority in environmental risk assessment. For the evaluation and monitoring of water quality, a series of methodologies may be applied. Among them, the worldwide used toxicity tests with organisms of the genus Daphnia is one of the most powerful. In recent years, some attempts were made to utilize Daphnia magna in genotoxicity testing as many of the new environmental contaminants are described as DNA-damaging agents in aquatic organisms. The aim of this research was to develop a highly standardized protocol of the Comet Assay adapted for D. magna, especially regarding the isolation of cells derived from the same tissue (haemolymph) from newborn organisms exposed in vivo. Several methods for haemolymph extraction and different Comet Assay parameters were compared. Electrophoretic conditions were adapted in order to obtain minimum DNA migration in cells derived from untreated organisms and, at the same time, maximum sensitivity in specimens treated with known genotoxicants (CdCl2 and H2O2). Additional tests were performed to investigate if life-history traits of the cladoceran (such as the age of adult organisms that provide newborns, the clutch size of origin, the number of generations reared in standard conditions) and the water composition as well, might influence the response of the assay. This study confirms the potential application of the Comet Assay in D. magna for assessing genotoxic loads in aqueous solution. The newly developed protocol could integrate the acute toxicity bioassay, thus expanding the possibility of using this model species in freshwater monitoring (waters, sediment and soil elutriates) and is in line with the spirit of the EU Water Framework Directive in reducing the number of bioassays that involve medium-sized species. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Development and validation of a real-time PCR assay for specific and sensitive detection of canid herpesvirus 1.

    Science.gov (United States)

    Decaro, Nicola; Amorisco, Francesca; Desario, Costantina; Lorusso, Eleonora; Camero, Michele; Bellacicco, Anna Lucia; Sciarretta, Rossana; Lucente, Maria Stella; Martella, Vito; Buonavoglia, Canio

    2010-10-01

    A TaqMan-based real-time PCR assay targeting the glycoprotein B-encoding gene was developed for diagnosis of canid herpesvirus 1 (CHV-1) infection. The established assay was highly specific, since no cross-reactions were observed with other canine DNA viruses, including canine parvovirus type 2, canine minute virus, or canine adenovirus types 1 and 2. The detection limit was 10(1) and 1.20 x 10(1) DNA copies per 10 microl(-1) of template for standard DNA and a CHV-1-positive kidney sample, respectively: about 1-log higher than a gel-based PCR assay targeting the thymidine kinase gene. The assay was also reproducible, as shown by satisfactory low intra-assay and inter-assay coefficients of variation. CHV-1 isolates of different geographical origins were recognised by the TaqMan assay. Tissues and clinical samples collected from three pups which died of CHV-1 neonatal infection were also tested, displaying a wide distribution of CHV-l DNA in their organs. Unlike other CHV-1-specific diagnostic methods, this quantitative assay permits simultaneous detection and quantitation of CHV-1 DNA in a wide range of canine tissues and body fluids, thus providing a useful tool for confirmation of a clinical diagnosis, for the study of viral pathogenesis and for evaluation of the efficacy of vaccines and antiviral drugs. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  1. Phylogenetic analysis of Fusobacterium prausnitzii based upon the 16S rRNA gene sequence and PCR confirmation.

    Science.gov (United States)

    Wang, R F; Cao, W W; Cerniglia, C E

    1996-01-01

    In order to develop a PCR method to detect Fusobacterium prausnitzii in human feces and to clarify the phylogenetic position of this species, its 16S rRNA gene sequence was determined. The sequence described in this paper is different from the 16S rRNA gene sequence is specific for F. prausnitzii, and the results of this assay confirmed that F. prausnitzii is the most common species in human feces. However, a PCR assay based on the original GenBank sequence was negative when it was performed with two strains of F. prausnitzii obtained from the American Type Culture Collection. A phylogenetic tree based on the new 16S rRNA gene sequence was constructed. On this tree F. prausnitzii was not a member of the Fusobacterium group but was closer to some Eubacterium spp. and located between Clostridium "clusters III and IV" (M.D. Collins, P.A. Lawson, A. Willems, J.J. Cordoba, J. Fernandez-Garayzabal, P. Garcia, J. Cai, H. Hippe, and J.A.E. Farrow, Int. J. Syst. Bacteriol. 44:812-826, 1994).

  2. Differentiating Botulinum Neurotoxin-Producing Clostridia with a Simple, Multiplex PCR Assay.

    Science.gov (United States)

    Williamson, Charles H D; Vazquez, Adam J; Hill, Karen; Smith, Theresa J; Nottingham, Roxanne; Stone, Nathan E; Sobek, Colin J; Cocking, Jill H; Fernández, Rafael A; Caballero, Patricia A; Leiser, Owen P; Keim, Paul; Sahl, Jason W

    2017-09-15

    NT-producing and nontoxigenic isolates can be found in each species, a PCR assay to determine the presence of the ntnh gene, which is a universally present component of bont gene clusters, and to provide information about the type ( ha + or orfX + ) of bont gene cluster present in a sample was also developed. The PCR assays provide simple, rapid, and inexpensive tools for screening uncharacterized isolates from clinical or environmental samples. The information provided by these assays can inform epidemiological studies, aid with identifying mixtures of isolates and unknown isolates in culture collections, and confirm the presence of bacteria of interest. Copyright © 2017 Williamson et al.

  3. Sensitive TSH assay in the assessment of thyroid function and its value in the follow-up of hyperthyroidism treated with radioiodine

    International Nuclear Information System (INIS)

    Masjhur, J.S.; Ilyas, R.A.M.

    1989-01-01

    This paper confirms the value of ''sensitive'' TSH assay in thyroid function assessment of untreated subjects and those who have undergone radioiodine treatment for hyperthyroidism from 120 patients. (ELC). 3 tabs.; 1 fig.; 7 refs

  4. Immunolabelling, histochemistry and in situ hybridisation in human skeletal muscle fibres to detect myosin heavy chain expression at the protein and mRNA level

    Science.gov (United States)

    SERRANO, A. L.; PÉREZ, MARGARITA; LUCÍA, A.; CHICHARRO, J. L.; QUIROZ-ROTHE, E.; RIVERO, J. L. L.

    2001-01-01

    The distribution of muscle fibres classified on the basis of their content of different myosin heavy chain (MHC) isoforms was analysed in vastus lateralis muscle biopsies of 15 young men (with an average age of 22 y) by correlating immunohistochemistry with specific anti-MHC monoclonal antibodies, myofibrillar ATPase (mATPase) histochemistry and in situ hybridisation with probes specific for MHC β-slow, MHC-IIA and MHC-IIX. The characterisation of a large number of individual fibres was compared and correlated on a fibre-to-fibre basis. The panel of monoclonal antibodies used in the study allowed classification of human skeletal muscle fibres into 5 categories according to the MHC isoform they express at the protein level, types I, I+IIA, IIA, IIAX and IIX. Hybrid fibres coexpressing two isoforms represented a considerable proportion of the fibre composition (about 14%) and were clearly underestimated by mATPase histochemistry. For a very high percentage of fibres there was a precise correspondence between the MHC protein isoforms and mRNA transcripts. The integrated methods used demonstrate a high degree of precision of the immunohistochemical procedure used for the identification and quantification of human skeletal muscle fibre types. The monoclonal antibody S5-8H2 is particularly useful for identifying hybrid IIAX fibres. This protocol offers new prospects for muscle fibre classification in human experimental studies. PMID:11554510

  5. Development and Assessment of Loop-Mediated Isothermal Amplification (LAMP) Assay for the Diagnosis of Human Visceral Leishmaniasis in Iran.

    Science.gov (United States)

    Ghasemian, Mehrdad; Gharavi, Mohammad Javad; Akhlaghi, Lame; Mohebali, Mehdi; Meamar, Ahmad Reza; Aryan, Ehsan; Oormazdi, Hormozd

    2014-03-01

    Parasitological methods for the diagnosis of Visceral leishmaniasis (VL) require invasive procedures, so serological and molecular approaches have been developed but are not generally applicable in the field. We evaluated a loop mediated isothermal amplification (LAMP) assay using blood from VL patients and compared it to nested PCR. Forty-seven subjects with clinical features (fever, hepatosplenomegaly and anemia) were confirmed positive for VL by the direct agglutination test (DAT) at titers >3200. Forty DAT negative individuals from non-endemic areas with no clinical signs or symptoms of VL served as controls. A LAMP assay was performed using a set of six primers targeting Leishmania infantum kinetoplast DNA (kDNA) minicircle gene under isothermal (64 °C) conditions. For nested PCR we used primers targeting the kDNA minicircle gene. The LAMP assay provided a detection limit of 1 parasite in 1 ml of peripheral blood and detected L. infantum DNA in 44 of 47 DAT-confirmed VL cases, with diagnostic sensitivity of 93.6% (95% CI). No L. infantum DNA was amplified in controls, indicating a specificity of 100%. The nested PCR yielded sensitivity of 96% (95% CI) and a specificity of 100% (95% CI). The LAMP assay gave results similar to those of nested PCR but in a shorter time. The LAMP method is simple; requires no sophisticated equipment; has a short reaction time; and results, indicated by turbidity of the reaction mixture, are observable with the naked eye.

  6. Development and Assessment of Loop-Mediated Isothermal Amplification (LAMP Assay for the Diagnosis of Human Visceral Leishmaniasis in Iran.

    Directory of Open Access Journals (Sweden)

    Mehrdad Ghasemian

    2014-03-01

    Full Text Available Parasitological methods for the diagnosis of Visceral leishmaniasis (VL require invasive procedures, so serological and molecular approaches have been developed but are not generally applicable in the field. We evaluated a loop mediated isothermal amplification (LAMP assay using blood from VL patients and compared it to nested PCR.Forty-seven subjects with clinical features (fever, hepatosplenomegaly and anemia were confirmed positive for VL by the direct agglutination test (DAT at titers >3200. Forty DAT negative individuals from non-endemic areas with no clinical signs or symptoms of VL served as controls. A LAMP assay was performed using a set of six primers targeting Leishmania infantum kinetoplast DNA (kDNA minicircle gene under isothermal (64 °C conditions. For nested PCR we used primers targeting the kDNA minicircle gene.The LAMP assay provided a detection limit of 1 parasite in 1 ml of peripheral blood and detected L. infantum DNA in 44 of 47 DAT-confirmed VL cases, with diagnostic sensitivity of 93.6% (95% CI. No L. infantum DNA was amplified in controls, indicating a specificity of 100%. The nested PCR yielded sensitivity of 96% (95% CI and a specificity of 100% (95% CI.The LAMP assay gave results similar to those of nested PCR but in a shorter time. The LAMP method is simple; requires no sophisticated equipment; has a short reaction time; and results, indicated by turbidity of the reaction mixture, are observable with the naked eye.

  7. Building predictive in vitro pulmonary toxicity assays using high-throughput imaging and artificial intelligence.

    Science.gov (United States)

    Lee, Jia-Ying Joey; Miller, James Alastair; Basu, Sreetama; Kee, Ting-Zhen Vanessa; Loo, Lit-Hsin

    2018-06-01

    Human lungs are susceptible to the toxicity induced by soluble xenobiotics. However, the direct cellular effects of many pulmonotoxic chemicals are not always clear, and thus, a general in vitro assay for testing pulmonotoxicity applicable to a wide variety of chemicals is not currently available. Here, we report a study that uses high-throughput imaging and artificial intelligence to build an in vitro pulmonotoxicity assay by automatically comparing and selecting human lung-cell lines and their associated quantitative phenotypic features most predictive of in vivo pulmonotoxicity. This approach is called "High-throughput In vitro Phenotypic Profiling for Toxicity Prediction" (HIPPTox). We found that the resulting assay based on two phenotypic features of a human bronchial epithelial cell line, BEAS-2B, can accurately classify 33 reference chemicals with human pulmonotoxicity information (88.8% balance accuracy, 84.6% sensitivity, and 93.0% specificity). In comparison, the predictivity of a standard cell-viability assay on the same set of chemicals is much lower (77.1% balanced accuracy, 84.6% sensitivity, and 69.5% specificity). We also used the assay to evaluate 17 additional test chemicals with unknown/unclear human pulmonotoxicity, and experimentally confirmed that many of the pulmonotoxic reference and predicted-positive test chemicals induce DNA strand breaks and/or activation of the DNA-damage response (DDR) pathway. Therefore, HIPPTox helps us to uncover these common modes-of-action of pulmonotoxic chemicals. HIPPTox may also be applied to other cell types or models, and accelerate the development of predictive in vitro assays for other cell-type- or organ-specific toxicities.

  8. The Comet Assay: Tails of the (Unexpected. Use of the comet assay in pharmaceutical development.

    Directory of Open Access Journals (Sweden)

    Bas-jan Van Der Leede

    2015-08-01

    Full Text Available In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by regulatory guidance. In this presentation we want to give insight into the circumstances in vivo comet assay is deployed in a Genetic Toxicology Department of a pharmaceutical company. As the in vivo comet assay is a salvage assay, it means that some events have occurred in an in vitro assay and that the compound (or metabolite responsible for this signal is potentially deselected for further development. More than often the decision to perform an in vivo comet assay is at a very early stage in development and the first time that the compound will be tested in vivo at high/toxic dose levels. As almost no toxicokinetic data and tissue distribution data are available a careful design with maximizes the chances for successful mitigation is necessary. Decisions on acute or repeated dosing need to be made and arrangements for combining the in vivo comet assay with the in vivo micronucleus assay are to be considered. Often synthesis methods need to be scaled up fast to provide the required amount of compound and information on suitable formulations needs to be in place. As exposure data is crucial for interpretation of results, analytical methods need to be brought in place rapidly. An experienced multi skilled and communicative team needs to be available to deploy successfully this kind of assays at an early stage of development. We will present a few scenarios on study conduct and demonstrate how this assay can make a difference for the further development of a new drug.

  9. Anaerobic microplate assay for direct microbial conversion of switchgrass and Avicel using Clostridium thermocellum

    Energy Technology Data Exchange (ETDEWEB)

    Oguntimein, Gbekeloluwa B. [Morgan State Univ., Baltimore, MD (United States); Rodriguez, Jr., Miguel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); National Lab., Oak Ridge, TN (United States). BioEnergy Science Center; Dumitrache, Alexandru [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); National Lab., Oak Ridge, TN (United States). BioEnergy Science Center; Shollenberger, Todd [National Renewable Energy Lab. (NREL), Golden, CO (United States); Decker, Stephen R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Davison, Brian H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); National Lab., Oak Ridge, TN (United States). BioEnergy Science Center; Brown, Steven D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); National Lab., Oak Ridge, TN (United States). BioEnergy Science Center; LanzaTech, Inc., Skokie, IL (United States)

    2017-11-09

    Here, to develop and prototype a high-throughput microplate assay to assess anaerobic microorganisms and lignocellulosic biomasses in a rapid, cost-effective screen for consolidated bioprocessing potential. Clostridium thermocellum parent Δhpt strain deconstructed Avicel to cellobiose, glucose, and generated lactic acid, formic acid, acetic acid and ethanol as fermentation products in titers and ratios similar to larger scale fermentations confirming the suitability of a plate-based method for C. thermocellum growth studies. C. thermocellum strain LL1210, with gene deletions in the key central metabolic pathways, produced higher ethanol titers in the Consolidated Bioprocessing (CBP) plate assay for both Avicel and switchgrass fermentations when compared to the Δhpt strain. A prototype microplate assay system is developed that will facilitate high-throughput bioprospecting for new lignocellulosic biomass types, genetic variants and new microbial strains for bioethanol production.

  10. Development of Rapid Isothermal Amplification Assays for Detection of Phytophthora spp. in Plant Tissue.

    Science.gov (United States)

    Miles, Timothy D; Martin, Frank N; Coffey, Michael D

    2015-02-01

    Several isothermal amplification techniques recently have been developed that are tolerant of inhibitors present in many plant extracts, which can reduce the need for obtaining purified DNA for running diagnostic assays. One such commercially available technique that has similarities with real-time polymerase chain reaction (PCR) for designing primers and a labeled probe is recombinase polymerase amplification (RPA). This technology was used to develop two simple and rapid approaches for detection of Phytophthora spp.: one genus-specific assay multiplexed with a plant internal control and the other species-specific assays for Phytophthora ramorum and P. kernoviae. All assays were tested for sensitivity (ranging from 3 ng to 1 fg of DNA) and specificity using DNA extracted from more than 136 Phytophthora taxa, 21 Pythium spp., 1 Phytopythium sp., and a wide range of plant species. The lower limit of linear detection using purified DNA was 200 to 300 fg of DNA in all pathogen RPA assays. Six different extraction buffers were tested for use during plant tissue maceration and the assays were validated in the field by collecting 222 symptomatic plant samples from over 50 different hosts. Only 56 samples were culture positive for Phytophthora spp. whereas 91 were positive using the Phytophthora genus-specific RPA test and a TaqMan real-time PCR assay. A technique for the generation of sequencing templates from positive RPA amplifications to confirm species identification was also developed. These RPA assays have added benefits over traditional technologies because they are rapid (results can be obtained in as little as 15 min), do not require DNA extraction or extensive training to complete, use less expensive portable equipment than PCR-based assays, and are significantly more specific than current immunologically based methods. This should provide a rapid, field-deployable capability for pathogen detection that will facilitate point-of-sample collection processing

  11. Radioreceptor assays: plasma membrane receptors and assays for polypeptide and glycoprotein hormones

    International Nuclear Information System (INIS)

    Schulster, D.

    1977-01-01

    Receptors for peptide, protein and glycoprotein hormones, and the catecholamines are located on the plasma membranes of their target cells. Preparations of the receptors may be used as specific, high-affinity binding agents for these hormones in assay methodology akin to that for radioimmunoassay. A particular advantage of the radioreceptor assay is that it has a specificity directed towards the biologically active region of the hormone, rather than to some immunologically active region that may have little (or no) involvement in the expression of hormonal activity. Methods for hormone receptor preparation vary greatly, and range from the use of intact cells (as the source of hormone receptor) to the use of purified or solubilized membrane receptors. Receptors isolated from plasma membranes have proved to be of variable stability, and may be damaged during preparation and/or storage. Moreover, since they are present in relatively low concentration in the cell, their preparation in sufficient quantity for use in a radioreceptor assay may present technical problems. In general, there is good correlation between radioreceptor assays and in-vitro bioassays; differences between results from radioreceptor assays and radioimmunoassays are similar to those noted between in-vitro bioassays and radioimmunoassays. The sensitivity of the method is such that normal plasma concentrations of various hormones have been assayed by this technique. (author)

  12. Sulfonylureas and Glinides as New PPARγ Agonists:. Virtual Screening and Biological Assays

    Science.gov (United States)

    Scarsi, Marco; Podvinec, Michael; Roth, Adrian; Hug, Hubert; Kersten, Sander; Albrecht, Hugo; Schwede, Torsten; Meyer, Urs A.; Rücker, Christoph

    2007-12-01

    This work combines the predictive power of computational drug discovery with experimental validation by means of biological assays. In this way, a new mode of action for type 2 diabetes drugs has been unvealed. Most drugs currently employed in the treatment of type 2 diabetes either target the sulfonylurea receptor stimulating insulin release (sulfonylureas, glinides), or target PPARγ improving insulin resistance (thiazolidinediones). Our work shows that sulfonylureas and glinides bind to PPARγ and exhibit PPARγ agonistic activity. This result was predicted in silico by virtual screening and confirmed in vitro by three biological assays. This dual mode of action of sulfonylureas and glinides may open new perspectives for the molecular pharmacology of antidiabetic drugs, since it provides evidence that drugs can be designed which target both the sulfonylurea receptor and PPARγ. Targeting both receptors could in principle allow to increase pancreatic insulin secretion, as well as to improve insulin resistance.

  13. Relationship between the radioisotopic footpad assay and other immunological assays in tumor bearing rats

    International Nuclear Information System (INIS)

    Mizushima, Yutaka; Takeichi, Noritoshi; Minami, Akio; Kasai, Masaharu; Itaya, Toshiyuki

    1981-01-01

    KMT-17, a fibrosarcoma induced by 3-methylcholanthrene in a WKA rat, is a sensitive tumor to various kinds of immunological assays and is a suitable model tumor for the study of the immune status in tumor bearing hosts. The antitumor immune response of KMT-17 bearing rats was studied by a radioisotopic footpad assay (FPA) in comparison with other in vivo and in vitro assays. Delayed hypersensitivity to tumor antigens measured by the FPA was observed from the 8th day after transplantation of KMT-17 cells, reached a peak on the 12 - 15th day, and then declined in the late stage on the 17th day. The kinetics of the FPA correlated well with those of an in vivo Winn assay and of an in vitro lymphocyte cytotoxicity assay ( 51 Cr-release assay). The appearance of an antitumor antibody detected by a complement dependent cytotoxicity test also correlated well with the kinetics of the FPA. A growth inhibition assay (GIA) for non-specific cell-mediated immunity also showed similar kinetics to that of the FPA. The delayed hypersensitivity footpad reaction to tumor cell extracts measured by this FPA was tumor-specific. These results suggest that the FPA is a simple and reliable in vivo assay for evaluating antitumor immunity in tumor bearing hosts. (author)

  14. Performance of a Multiplex Serological Helicobacter pylori Assay on a Novel Microfluidic Assay Platform

    Directory of Open Access Journals (Sweden)

    Angela Filomena

    2017-10-01

    Full Text Available Infection with Helicobacter pylori (H. pylori occurs in 50% of the world population, and is associated with the development of ulcer and gastric cancer. Serological diagnostic tests indicate an H. pylori infection by detecting antibodies directed against H. pylori proteins. In addition to line blots, multiplex assay platforms provide smart solutions for the simultaneous analysis of antibody responses towards several H. pylori proteins. We used seven H. pylori proteins (FliD, gGT, GroEL, HpaA, CagA, VacA, and HP0231 and an H. pylori lysate for the development of a multiplex serological assay on a novel microfluidic platform. The reaction limited binding regime in the microfluidic channels allows for a short incubation time of 35 min. The developed assay showed very high sensitivity (99% and specificity (100%. Besides sensitivity and specificity, the technical validation (intra-assay CV = 3.7 ± 1.2% and inter-assay CV = 5.5 ± 1.2% demonstrates that our assay is also a robust tool for the analysis of the H. pylori-specific antibody response. The integration of the virulence factors CagA and VacA allow for the assessment of the risk for gastric cancer development. The short assay time and the performance of the platform shows the potential for implementation of such assays in a clinical setting.

  15. Liquor oligoclonal bands assay: interpretation, correlation with other laboratory assays and importance for diagnostics of neurological disorders

    OpenAIRE

    Bagdonas, Dovydas

    2017-01-01

    Aim: to analyse the possible relationship between liquor IgG oligoclonal bands assay and other laboratory assays in neurological patients. Objectives: to determine the frequency of oligoclonal bands in neurological patients; to compare the results between serum and liquor laboratory assays in dependence of oligoclonal bands assay results; to evaluate the relationships between oligoclonal bands assay and serological-immunological assays for infectious diseases, gender, age and neurological ...

  16. Evaluation of a real-time PCR assay based on the single-copy SAG1 gene for the detection of Toxoplasma gondii.

    Science.gov (United States)

    Yu, Haijie; Huang, Bin; Zhuo, Xunhui; Chen, Xueqiu; Du, Aifang

    2013-11-08

    Real-time PCR-based detection of Toxoplasma gondii is very sensitive and convenient for diagnosing toxoplasmosis. However, the performance of the PCR assays could be influenced by the target gene chosen. Here we evaluate a real-time PCR assay using double-stranded DNA dyes (SYBR(®) Green I assay) with a new set of primers targeting the SAG1 gene for the fast and specific detection of T. gondii. The assay showed higher sensitivity than conventional PCR protocols using T. gondii DNA as template. The detection limit of the developed real-time PCR assay was in the order of 1 tachyzoite. The assay was also assessed by experimentally infected mice and showed positive results for blood (25%), spleen (50%) and lung (50%) as early as 1 dpi. The specificity of the assay was confirmed by using DNA from Neospora caninum, Escherichia coli, Babesia bovis, Trypanosoma brucei, Cryptosporidium parvum, and Toxocara canis. Assay applicability was successfully tested in blood samples collected from slaughtered pigs. These results indicate that, based on SYBR(®) green I, the quantitative SAG1 assay may also be useful in the study of the pathogenicity, immunoprophylaxis, and treatment of T. gondii. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Endogenous Locus Reporter Assays.

    Science.gov (United States)

    Liu, Yaping; Hermes, Jeffrey; Li, Jing; Tudor, Matthew

    2018-01-01

    Reporter gene assays are widely used in high-throughput screening (HTS) to identify compounds that modulate gene expression. Traditionally a reporter gene assay is built by cloning an endogenous promoter sequence or synthetic response elements in the regulatory region of a reporter gene to monitor transcriptional activity of a specific biological process (exogenous reporter assay). In contrast, an endogenous locus reporter has a reporter gene inserted in the endogenous gene locus that allows the reporter gene to be expressed under the control of the same regulatory elements as the endogenous gene, thus more accurately reflecting the changes seen in the regulation of the actual gene. In this chapter, we introduce some of the considerations behind building a reporter gene assay for high-throughput compound screening and describe the methods we have utilized to establish 1536-well format endogenous locus reporter and exogenous reporter assays for the screening of compounds that modulate Myc pathway activity.

  18. Solid-phase peptide quantitation assay using labeled monoclonal antibody and glutaraldehyde fixation

    International Nuclear Information System (INIS)

    Kasprzyk, P.G.; Cuttitta, F.; Avis, I.; Nakanishi, Y.; Treston, A.; Wong, H.; Walsh, J.H.; Mulshine, J.L.

    1988-01-01

    A solid-phase radioimmunoassay utilizing iodinated peptide-specific monoclonal antibody as a detection system instead of labeled peptide has been developed. Regional specific monoclonal antibodies to either gastrin-releasing peptide or gastrin were used as models to validate the general application of our modified assay. Conditions for radioactive labeling of the monoclonal antibody were determined to minimize oxidant damage, which compromises the sensitivity of other reported peptide quantitation assays. Pretreatment of 96-well polyvinyl chloride test plates with a 5% glutaraldehyde solution resulted in consistent retention of sufficient target peptide on the solid-phase matrix to allow precise quantitation. This quantitative method is completed within 1 h of peptide solid phasing. Pretreatment of assay plates with glutaraldehyde increased binding of target peptide and maximized antibody binding by optimizing antigen presentation. The hypothesis that glutaraldehyde affects both peptide binding to the plate and orientation of the peptide was confirmed by analysis of several peptide analogs. These studies indicate that peptide binding was mediated through a free amino group leaving the carboxy-terminal portion of the target peptide accessible for antibody binding. It was observed that the length of the peptide also affects the amount of monoclonal antibody that will bind. Under the optimal conditions, results from quantitation of gastrin-releasing peptide in relevant samples agree well with those from previously reported techniques. Thus, we report here a modified microplate assay which may be generally applied for the rapid and sensitive quantitation of peptide hormones

  19. Screening for ROS1 gene rearrangements in non-small cell lung cancers using immunohistochemistry with FISH confirmation is an effective method to identify this rare target

    Science.gov (United States)

    Selinger, Christina I; Li, Bob T; Pavlakis, Nick; Links, Matthew; Gill, Anthony J; Lee, Adrian; Clarke, Stephen; Tran, Thang N; Lum, Trina; Yip, Po Yee; Horvath, Lisa; Yu, Bing; Kohonen-Corish, Maija RJ; O’Toole, Sandra A; Cooper, Wendy A

    2016-01-01

    Aims To assess the prevalence of ROS1 rearrangements in a retrospective and prospective diagnostic Australian cohort and evaluate the effectiveness of immunohistochemical screening. Methods A retrospective cohort of 278 early stage lung adenocarcinomas and an additional 104 prospective NSCLC cases referred for routine molecular testing were evaluated. ROS1 immunohistochemistry (IHC) was performed (D4D6 clone, Cell Signaling Technology) on all cases as well as fluorescence in situ hybridisation (FISH) using the ZytoVision and Abbott Molecular ROS1 FISH probes, with ≥15% of cells with split signals considered positive for rearrangement. Results Eighty eight cases (32%) from the retrospective cohort showed staining by ROS1 IHC, and one case (0.4%) showed ROS1 rearrangement by FISH. Nineteen of the prospective diagnostic cases showed ROS1 IHC staining of which 12 (12%) cases were confirmed as ROS1 rearranged by FISH. There were no ROS1 rearranged cases that showed no expression of ROS1 with IHC. The ROS1 rearranged cases in the prospective cohort were all EGFR wildtype and ALK rearrangement negative. The sensitivity of ROS1 IHC in the retrospective cohort was 100% and specificity was 76%. Conclusions ROS1 rearrangements are rare events in lung adenocarcinomas. Selection of cases for ROS1 FISH testing, by excluding EGFR/ALK positive cases and use of IHC to screen for potentially positive cases can be used to enrich for the likelihood of a identifying a ROS1 rearranged lung cancer and prevent the need to undertake expensive and time consuming FISH testing in all cases. PMID:27599111

  20. Real-time reverse transcription-polymerase chain reaction assays for identification of wild poliovirus 1 & 3.

    Science.gov (United States)

    Sharma, Deepa K; Nalavade, Uma P; Deshpande, Jagadish M

    2015-10-01

    The poliovirus serotype identification and intratypic differentiation by real-time reverse transcription-polymerase chain reaction (rRT-PCR) assay is suitable for serotype mixtures but not for intratypic mixtures of wild and vaccine poliovirus strains. This study was undertaken to develop wild poliovirus 1 and 3 (WPV1 and WPV3) specific rRT-PCR assays for use. Specific primers and probes for rRT-PCR were designed based on VP1 sequences of WPV1 and WPV3 isolated in India since 2000. The specificity of the rRT-PCR assays was evaluated using WPV1 and WPV3 of different genetic lineages, non-polio enteroviruses (NPEVs) and mixtures of wild/wild and wild/Sabin vaccine strains. The sensitivity of the assays was determined by testing serial 10-fold dilutions of wild poliovirus 1 and 3 stock suspensions of known titre. No cross-reactivity with Sabin strains, intertypic wild poliovirus isolates or 27 types of NPEVs across all the four Enterovirus species was found for both the wild poliovirus 1 and 3 rRT-PCR assays. All WPV1 and WPV3 strains isolated since 2000 were successfully amplified. The rRT-PCR assays detected 10 4.40 CCID 50 /ml of WPV1 and 10 4.00 CCID 50 /ml of WPV3, respectively either as single isolate or mixture with Sabin vaccine strains or intertypic wild poliovirus. rRT-PCR assays for WPV1 and WPV3 have been validated to detect all the genetic variations of the WPV1 and WPV3 isolated in India for the last decade. When used in combination with the current rRT-PCR assay testing was complete for confirmation of the presence of wild poliovirus in intratypic mixtures.

  1. Identification of the first recurrent PAR1 deletion in Léri-Weill dyschondrosteosis and idiopathic short stature reveals the presence of a novel SHOX enhancer.

    Science.gov (United States)

    Benito-Sanz, Sara; Royo, Jose Luis; Barroso, Eva; Paumard-Hernández, Beatriz; Barreda-Bonis, Ana C; Liu, Pengfei; Gracía, Ricardo; Lupski, James R; Campos-Barros, Ángel; Gómez-Skarmeta, José Luis; Heath, Karen Elise

    2012-07-01

    SHOX, located in the pseudoautosomal region 1 (PAR1) of the sexual chromosomes, encodes a transcription factor implicated in human growth. Defects in SHOX or its enhancers have been observed in ∼60% of Leri-Weill dyschondrosteosis (LWD) patients, a skeletal dysplasia characterised by short stature and/or the characteristic Madelung deformity, and in 2-5% of idiopathic short stature (ISS). To identify the molecular defect in the remaining genetically undiagnosed LWD and ISS patients, this study screened previously unanalysed PAR1 regions in 124 LWD and 576 ISS probands. PAR1 screening was undertaken by multiplex ligation dependent probe amplification (MLPA). Copy number alterations were subsequently confirmed and delimited by locus-specific custom-designed MLPA, array comparative genomic hybridisation (CGH) and breakpoint junction PCR/sequencing. A recurrent PAR1 deletion downstream of SHOX spanning 47543 bp with identical breakpoints was identified in 19 LWD (15.3%) and 11 ISS (1.9%) probands, from 30 unrelated families. Eight evolutionarily conserved regions (ECRs 1-8) identified within the deleted sequence were evaluated for SHOX regulatory activity by means of chromosome conformation capture (3C) in chicken embryo limbs and luciferase reporter assays in human U2OS osteosarcoma cells. The 3C assay indicated potential SHOX regulatory activity by ECR1, which was subsequently confirmed to act as a SHOX enhancer, operating in an orientation and position independent manner, in human U2OS cells. This study has identified the first recurrent PAR1 deletion in LWD and ISS, which results in the loss of a previously uncharacterised SHOX enhancer. The loss of this enhancer may decrease SHOX transcription, resulting in LWD or ISS due to SHOX haploinsufficiency.

  2. Comparison of cobas HCV GT against Versant HCV Genotype 2.0 (LiPA) with confirmation by Sanger sequencing.

    Science.gov (United States)

    Yusrina, Falah; Chua, Cui Wen; Lee, Chun Kiat; Chiu, Lily; Png, Tracy Si-Yu; Khoo, Mui Joo; Yan, Gabriel; Lee, Guan Huei; Yan, Benedict; Lee, Hong Kai

    2018-05-01

    Correct identification of infecting hepatitis C virus (HCV) genotype is helpful for targeted antiviral therapy. Here, we compared the HCV genotyping performance of the cobas HCV GT assay against the Versant HCV Genotype 2.0 (LiPA) assay, using 97 archived serum samples. In the event of discrepant or indeterminate results produced by either assay, the core and NS5B regions were sequenced. Of the 97 samples tested by the cobas, 25 (26%) were deemed indeterminate. Sequencing analyses confirmed 21 (84%) of the 25 samples as genotype 6 viruses with either subtype 6m, 6n, 6v, 6xa, or unknown subtype. Of the 97 samples tested by the LiPA, thirteen (13%) were deemed indeterminate. Seven (7%) were assigned with genotype 1, with unavailable/inconclusive results from the core region of the LiPA. Notably, the 7 samples were later found to be either genotype 3 or 6 by sequencing analyses. Moreover, 1 sample by the LiPA was assigned as genotypes 4 (cobas: indeterminate) but were later found to be genotype 3 by sequencing analyses, highlighting its limitation in assigning the correct genotype. The cobas showed similar or slightly higher accuracy (100%; 95% CI 94-100%) compared to the LiPA (99%; 95% CI 92-100%). Twenty-six percent of the 97 samples tested by the cobas had indeterminate results, mainly due to its limitation in identifying genotype 6 other than subtypes 6a and 6b. This presents a significant assay limitation in Southeast Asia, where genotype 6 infection is highly prevalent. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Clonality analysis of lymphoid proliferations using the BIOMED-2 clonality assays: a single institution experience

    Science.gov (United States)

    Kokovic, Ira; Novakovic, Barbara Jezersek; Cerkovnik, Petra; Novakovic, Srdjan

    2014-01-01

    Background Clonality determination in patients with lymphoproliferative disorders can improve the final diagnosis. The aim of our study was to evaluate the applicative value of standardized BIOMED-2 gene clonality assay protocols for the analysis of clonality of lymphocytes in a group of different lymphoid proliferations. Materials and methods. With this purpose, 121 specimens from 91 patients with suspected lymphoproliferations submitted for routine diagnostics from January to December 2011 were retrospectively analyzed. According to the final diagnosis, our series comprised 32 cases of B-cell lymphomas, 38 cases of non-Hodgkin’s T-cell lymphomas and 51 cases of reactive lymphoid proliferations. Clonality testing was performed using the BIOMED-2 clonality assays. Results The determined sensitivity of the TCR assay was 91.9%, while the sensitivity of the IGH assay was 74.2%. The determined specificity of the IGH assay was 73.3% in the group of lymphomas and 87.2% in the group of reactive lesions. The determined specificity of the TCR assay was 62.5% in the group of lymphomas and 54.3% in the group of reactive lesions. Conclusions In the present study, we confirmed the utility of standardized BIOMED-2 clonality assays for the detection of clonality in a routine diagnostical setting of non-Hodgkin’s lymphomas. Reactions for the detection of the complete IGH rearrangements and reactions for the detection of the TCR rearrangements are a good choice for clonality testing of a wide range of lymphoid proliferations and specimen types while the reactions for the detection of incomplete IGH rearrangements have not shown any additional diagnostic value. PMID:24991205

  4. Kinetic assays for determining in vitro APS reductase activity in plants without the use of radioactive substances.

    Science.gov (United States)

    Brychkova, Galina; Yarmolinsky, Dmitry; Sagi, Moshe

    2012-09-01

    Adenosine 5'-phosphosulfate (APS) reductase (APR; EC 1.8.4.9) catalyzes the two-electron reduction of APS to sulfite and AMP, a key step in the sulfate assimilation pathway in higher plants. In spite of the importance of this enzyme, methods currently available for detection of APR activity rely on radioactive labeling and can only be performed in a very few specially equipped laboratories. Here we present two novel kinetic assays for detecting in vitro APR activity that do not require radioactive labeling. In the first assay, APS is used as substrate and reduced glutathione (GSH) as electron donor, while in the second assay APS is replaced by an APS-regenerating system in which ATP sulfurylase catalyzes APS in the reaction medium, which employs sulfate and ATP as substrates. Both kinetic assays rely on fuchsin colorimetric detection of sulfite, the final product of APR activity. Incubation of the desalted protein extract, prior to assay initiation, with tungstate that inhibits the oxidation of sulfite by sulfite oxidase activity, resulted in enhancement of the actual APR activity. The reliability of the two methods was confirmed by assaying leaf extract from Arabidopsis wild-type and APR mutants with impaired or overexpressed APR2 protein, the former lacking APR activity and the latter exhibiting much higher activity than the wild type. The assays were further tested on tomato leaves, which revealed a higher APR activity than Arabidopsis. The proposed APR assays are highly specific, technically simple and readily performed in any laboratory.

  5. Nested PCR Assay for Eight Pathogens: A Rapid Tool for Diagnosis of Bacterial Meningitis.

    Science.gov (United States)

    Bhagchandani, Sharda P; Kubade, Sushant; Nikhare, Priyanka P; Manke, Sonali; Chandak, Nitin H; Kabra, Dinesh; Baheti, Neeraj N; Agrawal, Vijay S; Sarda, Pankaj; Mahajan, Parikshit; Ganjre, Ashish; Purohit, Hemant J; Singh, Lokendra; Taori, Girdhar M; Daginawala, Hatim F; Kashyap, Rajpal S

    2016-02-01

    Bacterial meningitis is a dreadful infectious disease with a high mortality and morbidity if remained undiagnosed. Traditional diagnostic methods for bacterial meningitis pose a challenge in accurate identification of pathogen, making prognosis difficult. The present study is therefore aimed to design and evaluate a specific and sensitive nested 16S rDNA genus-based polymerase chain reaction (PCR) assay using clinical cerebrospinal fluid (CSF) for rapid diagnosis of eight pathogens causing the disease. The present work was dedicated to development of an in-house genus specific 16S rDNA nested PCR covering pathogens of eight genera responsible for causing bacterial meningitis using newly designed as well as literature based primers for respective genus. A total 150 suspected meningitis CSF obtained from the patients admitted to Central India Institute of Medical Sciences (CIIMS), India during the period from August 2011 to May 2014, were used to evaluate clinical sensitivity and clinical specificity of optimized PCR assays. The analytical sensitivity and specificity of our newly designed genus-specific 16S rDNA PCR were found to be ≥92%. With such a high sensitivity and specificity, our in-house nested PCR was able to give 100% sensitivity in clinically confirmed positive cases and 100% specificity in clinically confirmed negative cases indicating its applicability in clinical diagnosis. Our in-house nested PCR system therefore can diagnose the accurate pathogen causing bacterial meningitis and therefore be useful in selecting a specific treatment line to minimize morbidity. Results are obtained within 24 h and high sensitivity makes this nested PCR assay a rapid and accurate diagnostic tool compared to traditional culture-based methods.

  6. Rapid assay of resveratrol in red wine by paper spray tandem mass spectrometry and isotope dilution.

    Science.gov (United States)

    Di Donna, Leonardo; Taverna, Domenico; Indelicato, Serena; Napoli, Anna; Sindona, Giovanni; Mazzotti, Fabio

    2017-08-15

    A rapid analytical approach for the assay of resveratrol in red wines, based on Paper Spray Mass Spectrometry (PS-MS) and Multiple Reaction Monitoring (MRM) is described. The assay involves the use of the stable isotope dilution method. The analytical parameters calculated analyzing fortified samples confirm the reliability of the proposed approach, with accuracy values about 100%, and LOD and LOQ values calculated at 0.5 and 0.8μg/mL, respectively. Furthermore, both the recovery, which was quantitative for the analyte, and the reproducibility (RSD%), checked on different days on the same wine, always below 7%, highlighted the consistency of the methodology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Slight hypercalcemia is not associated with positive responses in the Comet Assay in male rat liver.

    Science.gov (United States)

    Thiel, Anette; Hamel, Annie; Schaefer, Katrien; Cardoso, Renato; Beilstein, Paul

    2017-08-01

    Maintenance of physiological levels of intracellular and extracellular calcium is essential for life. Increased intracellular calcium levels are involved in cell death (apoptosis and necrosis) and are associated with positive responses in the Comet assay in vitro. In addition, high calcium and vitamin D intakes were reported to induce apoptosis in adipose tissue in obese mice and to increase DNA-migration in the Comet assay. To investigate increased serum concentration of calcium as a potential confounding factor in the regulatory Comet assay in vivo, we induced mild hypercalcemia in male Wistar rats by 3-day continuous intravenous infusion of calcium gluconate and performed the Comet assay in the liver in line with regulatory guidelines. The results of the study showed that mild increases in serum calcium concentration (up to 1.4 times above the concurrent control) and increased urinary calcium concentration (up to 27.8 times above the concurrent control) results in clinical signs like mild tremor, faster respiration rate and decreased activity in a few animals. However, under the conditions of the study, no increase in the %Tail DNA in the Comet assay and no indication of liver damage as determined by histopathological means were observed. Thus, mild increases in plasma calcium did not lead to positive results in a genotoxicity assessment by the Comet assay in the rat liver. This result is important as it confirms the reliability of this assay for regulatory evaluation of safety. Copyright © 2017 DSM Nutritional Products AG. Published by Elsevier B.V. All rights reserved.

  8. [Clinical evaluation of a novel HBsAg quantitative assay].

    Science.gov (United States)

    Takagi, Kazumi; Tanaka, Yasuhito; Naganuma, Hatsue; Hiramatsu, Kumiko; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-07-01

    The clinical implication of the hepatitis B surface antigen (HBsAg) concentrations in HBV-infected individuals remains unclear. The aim of this study was to evaluate a novel fully automated Chemiluminescence Enzyme Immunoassay (Sysmex HBsAg quantitative assay) by comparative measurements of the reference serum samples versus two independent commercial assays (Lumipulse f or Architect HBsAg QT). Furthermore, clinical usefulness was assessed for monitoring of the serum HBsAg levels during antiviral therapy. A dilution test using 5 reference-serum samples showed linear correlation curve in range from 0.03 to 2,360 IU/ml. The HBsAg was measured in total of 400 serum samples and 99.8% had consistent results between Sysmex and Lumipulse f. Additionally, a positive linear correlation was observed between Sysmex and Architect. To compare the Architect and Sysmex, both methods were applied to quantify the HBsAg in serum samples with different HBV genotypes/subgenotypes, as well as in serum contained HBV vaccine escape mutants (126S, 145R). Correlation between the methods was observed in results for escape mutants and common genotypes (A, B, C) in Japan. Observed during lamivudine therapy, an increase in HBsAg and HBV DNA concentrations preceded the aminotransferase (ALT) elevation associated with drug-resistant HBV variant emergence (breakthrough hepatitis). In conclusion, reliability of the Sysmex HBsAg quantitative assay was confirmed for all HBV genetic variants common in Japan. Monitoring of serum HBsAg concentrations in addition to HBV DNA quantification, is helpful in evaluation of the response to lamivudine treatment and diagnosis of the breakthrough hepatitis.

  9. A Rapid Method for Quantifying Viable Mycobacterium avium subsp. paratuberculosis in Cellular Infection Assays

    Science.gov (United States)

    Pooley, Hannah B.; de Silva, Kumudika; Purdie, Auriol C.; Begg, Douglas J.; Whittington, Richard J.

    2016-01-01

    ABSTRACT Determining the viability of bacteria is a key outcome of in vitro cellular infection assays. Currently, this is done by culture, which is problematic for fastidious slow-growing bacteria such as Mycobacterium avium subsp. paratuberculosis, where it can take up to 4 months to confirm growth. This study aimed to identify an assay that can rapidly quantify the number of viable M. avium subsp. paratuberculosis cells in a cellular sample. Three commercially available bacterial viability assays along with a modified liquid culture method coupled with high-throughput quantitative PCR growth detection were assessed. Criteria for assessment included the ability of each assay to differentiate live and dead M. avium subsp. paratuberculosis organisms and their accuracy at low bacterial concentrations. Using the culture-based method, M. avium subsp. paratuberculosis growth was reliably detected and quantified within 2 weeks. There was a strong linear association between the 2-week growth rate and the initial inoculum concentration. The number of viable M. avium subsp. paratuberculosis cells in an unknown sample was quantified based on the growth rate, by using growth standards. In contrast, none of the commercially available viability assays were suitable for use with samples from in vitro cellular infection assays. IMPORTANCE Rapid quantification of the viability of Mycobacterium avium subsp. paratuberculosis in samples from in vitro cellular infection assays is important, as it allows these assays to be carried out on a large scale. In vitro cellular infection assays can function as a preliminary screening tool, for vaccine development or antimicrobial screening, and also to extend findings derived from experimental animal trials. Currently, by using culture, it takes up to 4 months to obtain quantifiable results regarding M. avium subsp. paratuberculosis viability after an in vitro infection assay; however, with the quantitative PCR and liquid culture method

  10. Use of the microculture kinetic assay of apoptosis to determine chemosensitivities of leukemias.

    Science.gov (United States)

    Kravtsov, V D; Greer, J P; Whitlock, J A; Koury, M J

    1998-08-01

    Chemotherapeutic agents exert their antitumor effects by inducing apoptosis. The microculture kinetic (MiCK) assay provides an automated, continuous means of monitoring apoptosis in a cell population. We used the MiCK assay to determine the chemosensitivities of the human promyelocytic HL-60 and lymphoblastic CEM cell lines and leukemia cells freshly isolated from patients with acute nonlymphocytic (ANLL) or acute lymphocytic (ALL) leukemias. Continuous monitoring of apoptosis in the MiCK assay permits determination of the time to the maximum apoptosis (Tm) and its two components which are initiation time (Ti) and development time (Td). Duration of the three timing components of apoptosis varies from hours to days depending on the drug, drug concentration, and type of target cells. In the MiCK assay, the extent of apoptosis is reported in kinetic units of apoptosis. Kinetic units are determined by the slope of the curve created when optical density caused by cell blebbing is plotted as a function of time. Using the leukemia cell lines, we define the relationship between kinetic units determined by the MiCK assay and the percentage of morphologically apoptotic cells in the culture. Flow cytometry analysis of apoptosis in Annexin-V-fluorescein isothiocyanate-labeled preparations of HL-60 and CEM cells was also used to compare with data obtained by the MiCK assay. The feasibility of the MiCK assay of apoptosis as a chemosensitivity test was confirmed by its comparison with a 3H-thymidine incorporation assay. We show that samples from 10 ANLL and ALL patients patients tested for sensitivity to various doses of idarubicin (IDR), daunorubicin (DNR), or mitoxantrone (MTA) gave the same percentages of apoptotic cells when calculated by the MiCK assay as when determined by morphological analysis. The MiCK assay was used for dose-response analyses of the sensitivities to IDR, DNR, and MTA of leukemia cells from 4 other patients (2 ANLL and 2 ALL). The results from both cell

  11. Direct 125I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    International Nuclear Information System (INIS)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.; Macpherson, J.S.

    1982-01-01

    Two direct radioimmunoassays for progesterone in 50 μL of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11α-hemisuccinyl conjugate and the radioligand 125 I-labeled progesterone 11α-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum

  12. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  13. Antibody-based assay discriminates Zika virus infection from other flaviviruses.

    Science.gov (United States)

    Balmaseda, Angel; Stettler, Karin; Medialdea-Carrera, Raquel; Collado, Damaris; Jin, Xia; Zambrana, José Victor; Jaconi, Stefano; Cameroni, Elisabetta; Saborio, Saira; Rovida, Francesca; Percivalle, Elena; Ijaz, Samreen; Dicks, Steve; Ushiro-Lumb, Ines; Barzon, Luisa; Siqueira, Patricia; Brown, David W G; Baldanti, Fausto; Tedder, Richard; Zambon, Maria; de Filippis, A M Bispo; Harris, Eva; Corti, Davide

    2017-08-01

    Zika virus (ZIKV) is a mosquito-borne flavivirus that emerged recently as a global health threat, causing a pandemic in the Americas. ZIKV infection mostly causes mild disease, but is linked to devastating congenital birth defects and Guillain-Barré syndrome in adults. The high level of cross-reactivity among flaviviruses and their cocirculation has complicated serological approaches to differentially detect ZIKV and dengue virus (DENV) infections, accentuating the urgent need for a specific and sensitive serological test. We previously generated a ZIKV nonstructural protein 1 (NS1)-specific human monoclonal antibody, which we used to develop an NS1-based competition ELISA. Well-characterized samples from RT-PCR-confirmed patients with Zika and individuals exposed to other flavivirus infections or vaccination were used in a comprehensive analysis to determine the sensitivity and specificity of the NS1 blockade-of-binding (BOB) assay, which was established in laboratories in five countries (Nicaragua, Brazil, Italy, United Kingdom, and Switzerland). Of 158 sera/plasma from RT-PCR-confirmed ZIKV infections, 145 (91.8%) yielded greater than 50% inhibition. Of 171 patients with primary or secondary DENV infections, 152 (88.9%) scored negative. When the control group was extended to patients infected by other flaviviruses, other viruses, or healthy donors ( n = 540), the specificity was 95.9%. We also analyzed longitudinal samples from DENV-immune and DENV-naive ZIKV infections and found inhibition was achieved within 10 d postonset of illness and maintained over time. Thus, the Zika NS1 BOB assay is sensitive, specific, robust, simple, low-cost, and accessible, and can detect recent and past ZIKV infections for surveillance, seroprevalence studies, and intervention trials.

  14. Assay method and compositions

    International Nuclear Information System (INIS)

    1977-01-01

    Methods are described for measuring catecholamine levels in human and animal body fluids and tissues using the catechol-O-methyl-transferase (COMT) radioassay. The assay involves incubating the biological sample with COMT and the tritiated methyl donor, S-adenosyl-L-methionine( 3 H)-methyl. The O-methylated ( 3 H) epinephrine and/or norepinephrine are extracted and oxidised to vanillin- 3 H which in turn is extracted and its radioactivity counted. When analysing dopamine levels the assay is extended by vanillin- 3 H and raising the pH of the aqueous periodate phase from which O-methylated ( 3 H) dopamine is extracted and counted. The assay may be modified depending on whether measurements of undifferentiated total endogenous catecholamine levels or differential analyses of the catecholamine levels are being performed. The sensitivity of the assay can be as low as 5 picograms for norepinephrine and epinephrine and 12 picograms for dopamine. The assemblance of the essential components of the assay into a kit for use in laboratories is also described. (U.K.)

  15. TaqMan real-time PCR assays for single-nucleotide polymorphisms which identify Francisella tularensis and its subspecies and subpopulations.

    Directory of Open Access Journals (Sweden)

    Dawn N Birdsell

    Full Text Available Francisella tularensis, the etiologic agent of tularemia and a Class A Select Agent, is divided into three subspecies and multiple subpopulations that differ in virulence and geographic distribution. Given these differences, there is a need to rapidly and accurately determine if a strain is F. tularensis and, if it is, assign it to subspecies and subpopulation. We designed TaqMan real-time PCR genotyping assays using eleven single nucleotide polymorphisms (SNPs that were potentially specific to closely related groups within the genus Francisella, including numerous subpopulations within F. tularensis species. We performed extensive validation studies to test the specificity of these SNPs to particular populations by screening the assays across a set of 565 genetically and geographically diverse F. tularensis isolates and an additional 21 genetic near-neighbor (outgroup isolates. All eleven assays correctly determined the genetic groups of all 565 F. tularensis isolates. One assay differentiates F. tularensis, F. novicida, and F. hispaniensis from the more genetically distant F. philomiragia and Francisella-like endosymbionts. Another assay differentiates F. tularensis isolates from near neighbors. The remaining nine assays classify F. tularensis-confirmed isolates into F. tularensis subspecies and subpopulations. The genotyping accuracy of these nine assays diminished when tested on outgroup isolates (i.e. non F. tularensis, therefore a hierarchical approach of assay usage is recommended wherein the F. tularensis-specific assay is used before the nine downstream assays. Among F. tularensis isolates, all eleven assays were highly sensitive, consistently amplifying very low concentrations of DNA. Altogether, these eleven TaqMan real-time PCR assays represent a highly accurate, rapid, and sensitive means of identifying the species, subspecies, and subpopulation of any F. tularensis isolate if used in a step-wise hierarchical scheme. These assays

  16. Development of a Rapid Fluorescence-Based High-Throughput Screening Assay to Identify Novel Kynurenine 3-Monooxygenase Inhibitor Scaffolds.

    Science.gov (United States)

    Jacobs, K R; Guillemin, G J; Lovejoy, D B

    2018-02-01

    Kynurenine 3-monooxygenase (KMO) is a well-validated therapeutic target for the treatment of neurodegenerative diseases, including Alzheimer's disease (AD) and Huntington's disease (HD). This work reports a facile fluorescence-based KMO assay optimized for high-throughput screening (HTS) that achieves a throughput approximately 20-fold higher than the fastest KMO assay currently reported. The screen was run with excellent performance (average Z' value of 0.80) from 110,000 compounds across 341 plates and exceeded all statistical parameters used to describe a robust HTS assay. A subset of molecules was selected for validation by ultra-high-performance liquid chromatography, resulting in the confirmation of a novel hit with an IC 50 comparable to that of the well-described KMO inhibitor Ro-61-8048. A medicinal chemistry program is currently underway to further develop our novel KMO inhibitor scaffolds.

  17. CERN confirms LHC schedule

    CERN Document Server

    2003-01-01

    The CERN Council held its 125th session on 20 June. Highlights of the meeting included confirmation that the LHC is on schedule for a 2007 start-up, and the announcement of a new organizational structure in 2004.

  18. A rapid, accurate and robust particle-based assay for the simultaneous screening of plasma samples for the presence of five different anti-cytokine autoantibodies

    DEFF Research Database (Denmark)

    Guldager, Daniel Kring Rasmussen; von Stemann, Jakob Hjorth; Larsen, Rune

    2015-01-01

    suitable for larger screenings. Based on confirmed antibody binding characteristics and the resultant reactivity in this multiplex assay, a classification of the c-aAb levels was suggested. The screening results of the recipients who received blood transfusions indicate that more studies are needed...... plasma samples and pooled normal immunoglobulin preparations were used to validate the assay. Plasma samples from 98 transfusion recipients, half of whom presented with febrile reactions, were tested by the assay. RESULTS: The assay detected specific and saturable immunoglobulin G (IgG) binding to each...... cytokine autoantibodies quantities in the negative plasma samples ranged between 80% and 125%. The analytical intra- and inter-assay variations were 4% and 11%, respectively. Varying c-aAb levels were detectable in the transfusion recipients. There was no difference in c-aAb frequency between the patients...

  19. "Life-like" assessment of antimicrobial surfaces by a new touch transfer assay displays strong superiority of a copper alloy compared to silver containing surfaces.

    Directory of Open Access Journals (Sweden)

    Johannes Karl-Mark Knobloch

    Full Text Available Transmission of bacteria from inanimate surfaces in healthcare associated environments is an important source of hospital acquired infections. A number of commercially available medical devices promise to fulfill antibacterial activity to reduce environmental contamination. In this study we developed a touch transfer assay modeling fingerprint transmission to investigate the antibacterial activity of surfaces, with confirmed antibacterial activity by a modified ISO 22196 (JIS Z 2801 assay to test such surfaces under more realistic conditions. Bacteria were taken up from a dry standardized primary contaminated surface (PCS with disinfected fingers or fingers covered with sterile and moistened cotton gloves. Subsequently, bacteria were transferred by pressing on secondary contaminated surfaces (SCS with or without potential antibacterial activity and the relative reduction rate was determined after 24 h. A stable transmission rate between PCS and SCS was observed using moistened sterile gloves. A copper containing alloy displayed at least a tenfold reduction of the bacterial load consistently reaching less than 2.5 cfu/cm2. In contrast, no significant reduction of bacterial contamination by silver containing surfaces and matured pure silver was observed in the touch transfer assay. With the touch transfer assay we successfully established a new reproducible method modeling cross contamination. Using the new method we were able to demonstrate that several surfaces with confirmed antimicrobial activity in a modified ISO 22196 (JIS Z 2801 assay lacked effectiveness under defined ambient conditions. This data indicate that liquid based assays like the ISO 22196 should be critically reviewed before claiming antibacterial activity for surfaces in the setting of contamination of dry surfaces by contact to the human skin. We suggest the newly developed touch transfer assay as a new additional tool for the assessment of potential antimicrobial surfaces

  20. Oligonucleotide arrays vs. metaphase-comparative genomic hybridisation and BAC arrays for single-cell analysis: first applications to preimplantation genetic diagnosis for Robertsonian translocation carriers.

    Science.gov (United States)

    Ramos, Laia; del Rey, Javier; Daina, Gemma; García-Aragonés, Manel; Armengol, Lluís; Fernandez-Encinas, Alba; Parriego, Mònica; Boada, Montserrat; Martinez-Passarell, Olga; Martorell, Maria Rosa; Casagran, Oriol; Benet, Jordi; Navarro, Joaquima

    2014-01-01

    Comprehensive chromosome analysis techniques such as metaphase-Comparative Genomic Hybridisation (CGH) and array-CGH are available for single-cell analysis. However, while metaphase-CGH and BAC array-CGH have been widely used for Preimplantation Genetic Diagnosis, oligonucleotide array-CGH has not been used in an extensive way. A comparison between oligonucleotide array-CGH and metaphase-CGH has been performed analysing 15 single fibroblasts from aneuploid cell-lines and 18 single blastomeres from human cleavage-stage embryos. Afterwards, oligonucleotide array-CGH and BAC array-CGH were also compared analysing 16 single blastomeres from human cleavage-stage embryos. All three comprehensive analysis techniques provided broadly similar cytogenetic profiles; however, non-identical profiles appeared when extensive aneuploidies were present in a cell. Both array techniques provided an optimised analysis procedure and a higher resolution than metaphase-CGH. Moreover, oligonucleotide array-CGH was able to define extra segmental imbalances in 14.7% of the blastomeres and it better determined the specific unbalanced chromosome regions due to a higher resolution of the technique (≈ 20 kb). Applicability of oligonucleotide array-CGH for Preimplantation Genetic Diagnosis has been demonstrated in two cases of Robertsonian translocation carriers 45,XY,der(13;14)(q10;q10). Transfer of euploid embryos was performed in both cases and pregnancy was achieved by one of the couples. This is the first time that an oligonucleotide array-CGH approach has been successfully applied to Preimplantation Genetic Diagnosis for balanced chromosome rearrangement carriers.

  1. Oligonucleotide arrays vs. metaphase-comparative genomic hybridisation and BAC arrays for single-cell analysis: first applications to preimplantation genetic diagnosis for Robertsonian translocation carriers.

    Directory of Open Access Journals (Sweden)

    Laia Ramos

    Full Text Available Comprehensive chromosome analysis techniques such as metaphase-Comparative Genomic Hybridisation (CGH and array-CGH are available for single-cell analysis. However, while metaphase-CGH and BAC array-CGH have been widely used for Preimplantation Genetic Diagnosis, oligonucleotide array-CGH has not been used in an extensive way. A comparison between oligonucleotide array-CGH and metaphase-CGH has been performed analysing 15 single fibroblasts from aneuploid cell-lines and 18 single blastomeres from human cleavage-stage embryos. Afterwards, oligonucleotide array-CGH and BAC array-CGH were also compared analysing 16 single blastomeres from human cleavage-stage embryos. All three comprehensive analysis techniques provided broadly similar cytogenetic profiles; however, non-identical profiles appeared when extensive aneuploidies were present in a cell. Both array techniques provided an optimised analysis procedure and a higher resolution than metaphase-CGH. Moreover, oligonucleotide array-CGH was able to define extra segmental imbalances in 14.7% of the blastomeres and it better determined the specific unbalanced chromosome regions due to a higher resolution of the technique (≈ 20 kb. Applicability of oligonucleotide array-CGH for Preimplantation Genetic Diagnosis has been demonstrated in two cases of Robertsonian translocation carriers 45,XY,der(13;14(q10;q10. Transfer of euploid embryos was performed in both cases and pregnancy was achieved by one of the couples. This is the first time that an oligonucleotide array-CGH approach has been successfully applied to Preimplantation Genetic Diagnosis for balanced chromosome rearrangement carriers.

  2. Oligonucleotide Arrays vs. Metaphase-Comparative Genomic Hybridisation and BAC Arrays for Single-Cell Analysis: First Applications to Preimplantation Genetic Diagnosis for Robertsonian Translocation Carriers

    Science.gov (United States)

    Ramos, Laia; del Rey, Javier; Daina, Gemma; García-Aragonés, Manel; Armengol, Lluís; Fernandez-Encinas, Alba; Parriego, Mònica; Boada, Montserrat; Martinez-Passarell, Olga; Martorell, Maria Rosa; Casagran, Oriol; Benet, Jordi; Navarro, Joaquima

    2014-01-01

    Comprehensive chromosome analysis techniques such as metaphase-Comparative Genomic Hybridisation (CGH) and array-CGH are available for single-cell analysis. However, while metaphase-CGH and BAC array-CGH have been widely used for Preimplantation Genetic Diagnosis, oligonucleotide array-CGH has not been used in an extensive way. A comparison between oligonucleotide array-CGH and metaphase-CGH has been performed analysing 15 single fibroblasts from aneuploid cell-lines and 18 single blastomeres from human cleavage-stage embryos. Afterwards, oligonucleotide array-CGH and BAC array-CGH were also compared analysing 16 single blastomeres from human cleavage-stage embryos. All three comprehensive analysis techniques provided broadly similar cytogenetic profiles; however, non-identical profiles appeared when extensive aneuploidies were present in a cell. Both array techniques provided an optimised analysis procedure and a higher resolution than metaphase-CGH. Moreover, oligonucleotide array-CGH was able to define extra segmental imbalances in 14.7% of the blastomeres and it better determined the specific unbalanced chromosome regions due to a higher resolution of the technique (≈20 kb). Applicability of oligonucleotide array-CGH for Preimplantation Genetic Diagnosis has been demonstrated in two cases of Robertsonian translocation carriers 45,XY,der(13;14)(q10;q10). Transfer of euploid embryos was performed in both cases and pregnancy was achieved by one of the couples. This is the first time that an oligonucleotide array-CGH approach has been successfully applied to Preimplantation Genetic Diagnosis for balanced chromosome rearrangement carriers. PMID:25415307

  3. Expert system for transuranic waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs.

  4. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  5. [Improvement of sensitivity in the second generation HCV core antigen assay by a novel concentration method using polyethylene glycol (PEG)].

    Science.gov (United States)

    Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Syundou, Hiromi; Saito, Hidetsugu

    2007-11-01

    A HCV core antigen (Ag) detection assay system, Lumipulse Ortho HCV Ag has been developed and is commercially available in Japan with a lower detection level limit of 50 fmol/l, which is equivalent to 20 KIU/ml in PCR quantitative assay. HCV core Ag assay has an advantage of broader dynamic range compared with PCR assay, however the sensitivity is lower than PCR. We developed a novel HCV core Ag concentration method using polyethylene glycol (PEG), which can improve the sensitivity five times better than the original assay. The reproducibility was examined by consecutive five-time measurement of HCV patients serum, in which the results of HCV core Ag original and concentrated method were 56.8 +/- 8.1 fmol/l (mean +/- SD), CV 14.2% and 322.9 +/- 45.5 fmol/l CV 14.0%, respectively. The assay results of HCV negative samples in original HCV core Ag were all 0.1 fmol/l and the results were same even in the concentration method. The results of concentration method were 5.7 times higher than original assay, which was almost equal to theoretical rate as expected. The assay results of serially diluted samples were also as same as expected data in both original and concentration assay. We confirmed that the sensitivity of HCV core Ag concentration method had almost as same sensitivity as PCR high range assay in the competitive assay study using the serially monitored samples of five HCV patients during interferon therapy. A novel concentration method using PEG in HCV core Ag assay system seems to be useful for assessing and monitoring interferon treatment for HCV.

  6. Evaluation of the larval migration inhibition assay for detecting macrocyclic lactone resistance in Dirofilaria immitis.

    Science.gov (United States)

    Evans, Christopher C; Moorhead, Andrew R; Storey, Bobby E; Blagburn, Byron L; Wolstenholme, Adrian J; Kaplan, Ray M

    2017-11-15

    Anthelmintics of the macrocyclic lactone (ML) drug class are widely used as preventives against the canine heartworm (Dirofilaria immitis). Over the past several years, however, reports of ML lack of efficacy (LOE) have emerged, in which dogs develop mature heartworm infection despite the administration of monthly prophylactics. More recently, isolates from LOE cases have been used to infect laboratory dogs and the resistant phenotype has been confirmed by the establishment of adult worms in the face of ML treatment at normally preventive dosages. Testing for and monitoring resistance in D. immitis requires a validated biological or molecular diagnostic assay. In this study, we assessed a larval migration inhibition assay (LMIA) that we previously optimized for use with D. immitis third-stage larvae (L 3 ). We used this assay to measure the in vitro ML susceptibilities of a known-susceptible laboratory strain of D. immitis and three highly suspected ML-resistant isolates originating from three separate LOE cases; progeny from two of these isolates have been confirmed ML-resistant by treatment of an infected dog in a controlled setting. A nonlinear regression model was fit to the dose-response data, from which IC 50 values were calculated. The D. immitis LMIA yielded consistent and reproducible dose-response data; however, no statistically significant differences in drug susceptibility were observed between control and LOE parasites. Additionally, the drug concentrations needed to paralyze the L 3 were much higher than those third- and fourth-stage larvae would experience in vivo. IC 50 values ranged from 1.57 to 5.56μM (p≥0.19). These data could suggest that ML resistance in this parasite is not mediated through a reduced susceptibility of L 3 to the paralytic effects of ML drugs, and therefore motility-based assays are likely not appropriate for measuring the effects of MLs against D. immitis in this target stage. Published by Elsevier B.V.

  7. Enzymatic assays for the diagnosis of bradykinin-dependent angioedema.

    Directory of Open Access Journals (Sweden)

    Federica Defendi

    Full Text Available BACKGROUND: The kinins (primarily bradykinin, BK represent the mediators responsible for local increase of vascular permeability in hereditary angioedema (HAE, HAE I-II associated with alterations of the SERPING1 gene and HAE with normal C1-Inhibitor function (HAE-nC1INH. Besides C1-Inhibitor function and concentration, no biological assay of kinin metabolism is actually available to help physicians for the diagnosis of angioedema (AE. We describe enzymatic tests on the plasma for diagnosis of BK-dependent AE. METHODS: The plasma amidase assays are performed using the Pro-Phe-Arg-p-nitroanilide peptide substrate to evaluate the spontaneous amidase activity and the proenzyme activation. We analyzed data of 872 patients presenting with BK-dependent AE or BK-unrelated diseases, compared to 303 controls. Anti-high MW kininogen (HK immunoblot was achieved to confirm HK cleavage in exemplary samples. Reproducibility, repeatability, limit of blank, limit of detection, precision, linearity and receiver operating characteristics (ROC were used to calculate the diagnostic performance of the assays. RESULTS: Spontaneous amidase activity was significantly increased in all BK-dependent AE, associated with the acute phase of disease in HAE-nC1INH, but preserved in BK-unrelated disorders. The increase of the amidase activity was associated to HK proteolysis, indicating its relevance to identify kininogenase activity. The oestrogens, known for precipitating AE episodes, were found as triggers of enzymatic activity. Calculations from ROC curves gave the optimum diagnostic cut-off for women (9.3 nmol⋅min(-1⋅mL(-1, area under curve [AUC] 92.1%, sensitivity 80.0%, and specificity 90.1% and for men (6.6 nmol·min(-1⋅mL(-1, AUC 91.0%, sensitivity 87.0% and specificity 81.2%. CONCLUSION: The amidase assay represents a diagnostic tool to help physicians in the decision to distinguish between BK-related and -unrelated AE.

  8. Comparison of single serum progesterone and endometrial biopsy for confirmation of ovulation in infertile Nigerian women.

    Science.gov (United States)

    Ilesanmi, A O; Adeleye, J A; Osotimehin, B O

    1995-03-01

    Infertility remains a medico-social problem in Nigeria and it accounts for a large percentage of outpatient gynecological consultations. The evaluation of the infertile couple remains a continuing challenge to the practising doctor in this part of the world. The need to evaluate the two methods commonly used for determining ovulation in these patients is indicated. Endometrial biopsy specimen and a single sample for serum progesterone estimation were obtained simultaneously in the luteal phase from 50 normally menstruating infertile Nigerian women. Subsequent analysis showed that a serum progesterone value of 6.6 nmol/l (2.2 ng/ml) or above was always associated with a secretory endometrium. Forty-six cycles yielded sufficient information to compare the two methods for confirmation of ovulation. Patients who ovulated with a progesterone value of 6.6 nmol/l (2.2 ng/ml) were 91.3% (42/46) or above, while 89% (41/46) showed secretory endometrium. Forty-six of the cases 86.9% (40/46) were judged to have ovulated by both parameters while 6.5% demonstrated anovulatory cycle using both criteria. From the study, a significant correlation was obtained between endometrial biopsy and progesterone assay methods in confirming ovulation.

  9. A homogeneous, high-throughput assay for phosphatidylinositol 5-phosphate 4-kinase with a novel, rapid substrate preparation.

    Directory of Open Access Journals (Sweden)

    Mindy I Davis

    Full Text Available Phosphoinositide kinases regulate diverse cellular functions and are important targets for therapeutic development for diseases, such as diabetes and cancer. Preparation of the lipid substrate is crucial for the development of a robust and miniaturizable lipid kinase assay. Enzymatic assays for phosphoinositide kinases often use lipid substrates prepared from lyophilized lipid preparations by sonication, which result in variability in the liposome size from preparation to preparation. Herein, we report a homogeneous 1536-well luciferase-coupled bioluminescence assay for PI5P4Kα. The substrate preparation is novel and allows the rapid production of a DMSO-containing substrate solution without the need for lengthy liposome preparation protocols, thus enabling the scale-up of this traditionally difficult type of assay. The Z'-factor value was greater than 0.7 for the PI5P4Kα assay, indicating its suitability for high-throughput screening applications. Tyrphostin AG-82 had been identified as an inhibitor of PI5P4Kα by assessing the degree of phospho transfer of γ-(32P-ATP to PI5P; its inhibitory activity against PI5P4Kα was confirmed in the present miniaturized assay. From a pilot screen of a library of bioactive compounds, another tyrphostin, I-OMe tyrphostin AG-538 (I-OMe-AG-538, was identified as an ATP-competitive inhibitor of PI5P4Kα with an IC(50 of 1 µM, affirming the suitability of the assay for inhibitor discovery campaigns. This homogeneous assay may apply to other lipid kinases and should help in the identification of leads for this class of enzymes by enabling high-throughput screening efforts.

  10. First results with a radioreceptor-assay (TRAK-Assay) for TSH-receptor-autoantibodies

    International Nuclear Information System (INIS)

    Becker, W.; Reiners, C.; Boerner, W.

    1983-01-01

    A new radioreceptor-assay (TRAK-assay) for autoantibodies against TSH-receptors was tested in 48 untreated thyrotoxic patients (26 regional autonomies, 22 toxic diffuse goiters). None of the 26 patients with regional autonomy showed positive autoantibody-titers. 4 patients with toxic diffuse goiter and thyrotoxic exophthalmos were TRAK-positive. Positive titers of microsomal and thyreoglobulin autoantibodies could be seen in 8 of 9 patients with positive TRAK-titers. In accordance with the conventional methods for detecting thyroid-stimulating immunoglobulins the new TRAK-assay seems to be suited for differentiating between immunogenic toxic diffuse goiter (Graves' disease) and goiter with disseminated autonomy as well as for prediction of relapse. (orig.) [de

  11. Evaluation of the performance of the reduced local lymph node assay for skin sensitization testing.

    Science.gov (United States)

    Ezendam, Janine; Muller, Andre; Hakkert, Betty C; van Loveren, Henk

    2013-06-01

    The local lymph node assay (LLNA) is the preferred method for classification of sensitizers within REACH. To reduce the number of mice for the identification of sensitizers the reduced LLNA was proposed, which uses only the high dose group of the LLNA. To evaluate the performance of this method for classification, LLNA data from REACH registrations were used and classification based on all dose groups was compared to classification based on the high dose group. We confirmed previous examinations of the reduced LLNA showing that this method is less sensitive compared to the LLNA. The reduced LLNA misclassified 3.3% of the sensitizers identified in the LLNA and misclassification occurred in all potency classes and that there was no clear association with irritant properties. It is therefore not possible to predict beforehand which substances might be misclassified. Another limitation of the reduced LLNA is that skin sensitizing potency cannot be assessed. For these reasons, it is not recommended to use the reduced LLNA as a stand-alone assay for skin sensitization testing within REACH. In the future, the reduced LLNA might be of added value in a weight of evidence approach to confirm negative results obtained with non-animal approaches. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Immunological assays employed for the elucidation of an histoplasmosis outbreak in São Paulo, SP

    Directory of Open Access Journals (Sweden)

    Angela Noronha Passos

    2014-12-01

    Full Text Available Several reports showed outbreaks of histoplasmosis acquired while bat-inhabited caves were visited by tourists, miners or researchers. We evaluated the performance of double immunodifusion (DI and immunoblotting (IB assays, employed for the histoplasmosis outbreak elucidation occurred in Vale do Paraíba, São Paulo. The existence of epidemiologic link, four patients with clinical signs suggestive of histoplasmosis and mycological confirmation has made that all 35 individuals involved to the cave visit were subjected to serological evaluation. By DI, we observed reactivity against H. capsulatum antigen in a single serum examined nearly 20 days after exposure to fungal propagules. On the other hand, IB showed reactivity against H and M fractions in 50% of samples evaluated. The analysis of the second sample batch, collected two months after the exposure showed that 96.7% were reactive by DI with antibodies titers ranging from 1 to 16 and 100% of reactivity against H and M fractions, by IB, suggesting an acute infection. The analysis of the overall agreement between the methods showed to be reasonable (κ = 0.37. This study confirms the importance and efficacy of more sensitive methodologies, such as IB assay, to early elucidation of disease, especially in cases of patients without mycological information.

  13. Comprehensive analysis of sperm DNA fragmentation by five different assays: TUNEL assay, SCSA, SCD test and alkaline and neutral Comet assay.

    Science.gov (United States)

    Ribas-Maynou, J; García-Peiró, A; Fernández-Encinas, A; Abad, C; Amengual, M J; Prada, E; Navarro, J; Benet, J

    2013-09-01

    Sperm DNA fragmentation (SDF) is becoming an important test to assess male infertility. Several different tests are available, but no consensus has yet been reached as to which tests are most predictive of infertility. Few publications have reported a comprehensive analysis comparing these methods within the same population. The objective of this study was to analyze the differences between the five most common methodologies, to study their correlations and to establish their cut-off values, sensitivity and specificity in predicting male infertility. We found differences in SDF between fertile donors and infertile patients in TUNEL, SCSA, SCD and alkaline Comet assays, but none with the neutral Comet assay. The alkaline COMET assay was the best in predicting male infertility followed by TUNEL, SCD and SCSA, whereas the neutral COMET assay had no predictive power. For our patient population, threshold values for infertility were 20.05% for TUNEL assay, 18.90% for SCSA, 22.75% for the SCD test, 45.37% for alkaline Comet and 34.37% for neutral Comet. This work establishes in a comprehensive study that the all techniques except neutral Comet are useful to distinguish fertile and infertile men. © 2013 American Society of Andrology and European Academy of Andrology.

  14. In vitro effects of piracetam on the radiosensitivity of hypoxic cells (adaptation of MTT assay to hypoxic conditions)

    International Nuclear Information System (INIS)

    Gheuens, E.E.O.; Bruijn, E.A. de; Van der Heyden, S.; Van Oosterom, A.T.; Lagarde, P.; Pooter, C.M.J. de; Chomy, F.

    1995-01-01

    This paper describes the adaptation of the MTT assay to hypoxic conditions in order to test the in vitro effect of piracetam on hypoxic cells and particularly on the radiosensitivity of hypoxic cells since this drug has shown clinical effect on acute and chronic hypoxia. The V79 cell line was selected by reference to preliminary hypoxic experiments using clonogenic assay and euoxic experiments using clonogenic and MTT assays. Cell growth and survival in our hypoxic conditions were assessed using MTT assay with an enclosure and special 48-well plates both made of glass. Growth curves on glass plates after 1-hour exposure to nitrogen versus air were comparable, so there is no bias effect due to gas composition. Survival curves using MTT versus reference clonogenic assay were comparable after radiation exposure in eu- and hypoxic conditions, and confirm the validity of our original technique for creating hypoxia. The Oxygen Enhancement Ratio was of about 3 for 1-hour hypoxic exposure. Piracetam gave no cytotoxic effect up to 10 mM of piracetam. Growth curves after continuous drug exposure and 1-hour euoxic versus hypoxic exposure gave no cytotoxic effect up to 10 mM of piracetam. Survival curves after continuous drug exposure to 10 mM of piracetam gave no significant effect on the radiosensitivity of hypoxic V79 cells using MTT or clonogenic assay. (author). 32 refs., 6 figs

  15. Rapid molecular assays for the detection of yellow fever virus in low-resource settings.

    Science.gov (United States)

    Escadafal, Camille; Faye, Oumar; Sall, Amadou Alpha; Faye, Ousmane; Weidmann, Manfred; Strohmeier, Oliver; von Stetten, Felix; Drexler, Josef; Eberhard, Michael; Niedrig, Matthias; Patel, Pranav

    2014-03-01

    Yellow fever (YF) is an acute viral hemorrhagic disease transmitted by Aedes mosquitoes. The causative agent, the yellow fever virus (YFV), is found in tropical and subtropical areas of South America and Africa. Although a vaccine is available since the 1930s, YF still causes thousands of deaths and several outbreaks have recently occurred in Africa. Therefore, rapid and reliable diagnostic methods easy to perform in low-resources settings could have a major impact on early detection of outbreaks and implementation of appropriate response strategies such as vaccination and/or vector control. The aim of this study was to develop a YFV nucleic acid detection method applicable in outbreak investigations and surveillance studies in low-resource and field settings. The method should be simple, robust, rapid and reliable. Therefore, we adopted an isothermal approach and developed a recombinase polymerase amplification (RPA) assay which can be performed with a small portable instrument and easy-to-use lyophilized reagents. The assay was developed in three different formats (real-time with or without microfluidic semi-automated system and lateral-flow assay) to evaluate their application for different purposes. Analytical specificity and sensitivity were evaluated with a wide panel of viruses and serial dilutions of YFV RNA. Mosquito pools and spiked human plasma samples were also tested for assay validation. Finally, real-time RPA in portable format was tested under field conditions in Senegal. The assay was able to detect 20 different YFV strains and demonstrated no cross-reactions with closely related viruses. The RPA assay proved to be a robust, portable method with a low detection limit (<21 genome equivalent copies per reaction) and rapid processing time (<20 min). Results from real-time RPA field testing were comparable to results obtained in the laboratory, thus confirming our method is suitable for YFV detection in low-resource settings.

  16. Rapid molecular assays for the detection of yellow fever virus in low-resource settings.

    Directory of Open Access Journals (Sweden)

    Camille Escadafal

    2014-03-01

    Full Text Available BACKGROUND: Yellow fever (YF is an acute viral hemorrhagic disease transmitted by Aedes mosquitoes. The causative agent, the yellow fever virus (YFV, is found in tropical and subtropical areas of South America and Africa. Although a vaccine is available since the 1930s, YF still causes thousands of deaths and several outbreaks have recently occurred in Africa. Therefore, rapid and reliable diagnostic methods easy to perform in low-resources settings could have a major impact on early detection of outbreaks and implementation of appropriate response strategies such as vaccination and/or vector control. METHODOLOGY: The aim of this study was to develop a YFV nucleic acid detection method applicable in outbreak investigations and surveillance studies in low-resource and field settings. The method should be simple, robust, rapid and reliable. Therefore, we adopted an isothermal approach and developed a recombinase polymerase amplification (RPA assay which can be performed with a small portable instrument and easy-to-use lyophilized reagents. The assay was developed in three different formats (real-time with or without microfluidic semi-automated system and lateral-flow assay to evaluate their application for different purposes. Analytical specificity and sensitivity were evaluated with a wide panel of viruses and serial dilutions of YFV RNA. Mosquito pools and spiked human plasma samples were also tested for assay validation. Finally, real-time RPA in portable format was tested under field conditions in Senegal. CONCLUSION/SIGNIFICANCE: The assay was able to detect 20 different YFV strains and demonstrated no cross-reactions with closely related viruses. The RPA assay proved to be a robust, portable method with a low detection limit (<21 genome equivalent copies per reaction and rapid processing time (<20 min. Results from real-time RPA field testing were comparable to results obtained in the laboratory, thus confirming our method is suitable for

  17. Serological Assays Based on Recombinant Viral Proteins for the Diagnosis of Arenavirus Hemorrhagic Fevers

    Directory of Open Access Journals (Sweden)

    Masayuki Saijo

    2012-10-01

    Full Text Available The family Arenaviridae, genus Arenavirus, consists of two phylogenetically independent groups: Old World (OW and New World (NW complexes. The Lassa and Lujo viruses in the OW complex and the Guanarito, Junin, Machupo, Sabia, and Chapare viruses in the NW complex cause viral hemorrhagic fever (VHF in humans, leading to serious public health concerns. These viruses are also considered potential bioterrorism agents. Therefore, it is of great importance to detect these pathogens rapidly and specifically in order to minimize the risk and scale of arenavirus outbreaks. However, these arenaviruses are classified as BSL-4 pathogens, thus making it difficult to develop diagnostic techniques for these virus infections in institutes without BSL-4 facilities. To overcome these difficulties, antibody detection systems in the form of an enzyme-linked immunosorbent assay (ELISA and an indirect immunofluorescence assay were developed using recombinant nucleoproteins (rNPs derived from these viruses. Furthermore, several antigen-detection assays were developed. For example, novel monoclonal antibodies (mAbs to the rNPs of Lassa and Junin viruses were generated. Sandwich antigen-capture (Ag-capture ELISAs using these mAbs as capture antibodies were developed and confirmed to be sensitive and specific for detecting the respective arenavirus NPs. These rNP-based assays were proposed to be useful not only for an etiological diagnosis of VHFs, but also for seroepidemiological studies on VHFs. We recently developed arenavirus neutralization assays using vesicular stomatitis virus (VSV-based pseudotypes bearing arenavirus recombinant glycoproteins. The goal of this article is to review the recent advances in developing laboratory diagnostic assays based on recombinant viral proteins for the diagnosis of VHFs and epidemiological studies on the VHFs caused by arenaviruses.

  18. An accurate method for quantifying and analyzing copy number variation in porcine KIT by an oligonucleotide ligation assay

    Directory of Open Access Journals (Sweden)

    Cho In-Cheol

    2007-11-01

    Full Text Available Abstract Background Aside from single nucleotide polymorphisms, copy number variations (CNVs are the most important factors in susceptibility to genetic disorders because they affect expression levels of genes. In previous studies, pyrosequencing, mini-sequencing, real-time PCR, invader assays and other techniques have been used to detect CNVs. However, the higher the copy number in a genome, the more difficult it is to resolve the copies, so a more accurate method for measuring CNVs and assigning genotype is needed. Results PCR followed by a quantitative oligonucleotide ligation assay (qOLA was developed for quantifying CNVs. The accuracy and precision of the assay were evaluated for porcine KIT, which was selected as a model locus. Overall, the root mean squares of bias and standard deviation of qOLA were 2.09 and 0.45, respectively. These values are less than half of those in the published pyrosequencing assay for analyzing CNV in porcine KIT. Using a combined method of qOLA and another pyrosequencing for quantitative analysis of KIT copies with spliced forms, we confirmed the segregation of KIT alleles in 145 F1 animals with pedigree information and verified the correct assignment of genotypes. In a diagnostic test on 100 randomly sampled commercial pigs, there was perfect agreement between the genotypes obtained by grouping observations on a scatter plot and by clustering using the nearest centroid sorting method implemented in PROC FASTCLUS of the SAS package. In a test on 159 Large White pigs, there were only two discrepancies between genotypes assigned by the two clustering methods (98.7% agreement, confirming that the quantitative ligation assay established here makes genotyping possible through the accurate measurement of high KIT copy numbers (>4 per diploid genome. Moreover, the assay is sensitive enough for use on DNA from hair follicles, indicating that DNA from various sources could be used. Conclusion We have established a high

  19. Correlation of liquid chromatographic and biological assay for potency assessment of filgrastim and related impurities.

    Science.gov (United States)

    Skrlin, Ana; Kosor Krnic, Ela; Gosak, Darko; Prester, Berislav; Mrsa, Vladimir; Vuletic, Marko; Runac, Domagoj

    2010-11-02

    In vivo and in vitro potency assays have always been a critical tool for confirmation of protein activity. However, due to their complexity and time consuming procedures, it remains a challenge to find an alternative analytical approach that would enable their replacement with no impact on the quality of provided information. The goal of this research was to determine if a correlation between liquid chromatography assays and in vitro biological assay could be established for filgrastim (recombinant human granulocyte-colony stimulating factor, rhG-CSF) samples containing various amounts of related impurities. For that purpose, relevant filgrastim related impurities were purified to homogeneity and characterized by liquid chromatography and mass spectrometry. A significant correlation (R(2)>0.90) between the two types of assays was revealed. Potency of oxidized filgrastim was determined to be approximately 25% of filgrastim stated potency (1 x 10(8)IU/mg of protein). Formyl-methionine filgrastim had potency of 89% of the filgrastim stated potency, while filgrastim dimer had 67% of filgrastim stated potency. A mathematical model for the estimation of biological activity of filgrastim samples from chromatography data was established and a significant correlation between experimental potency values and potency values estimated by the mathematical model was obtained (R(2)=0.92). Based on these results a conclusion was made that reversed phase high performance liquid chromatography could be used as an alternative for the in vitro biological assay for potency assessment of filgrastim samples. Such an alternative model would enable substitution of a complex and time consuming biological assay with a robust and precise instrumental method in many practical cases. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  20. The development and application of the two real-time RT-PCR assays to detect the pathogen of HFMD.

    Directory of Open Access Journals (Sweden)

    Aili Cui

    Full Text Available Large-scale Hand, Foot, and Mouth Disease (HFMD outbreaks have frequently occurred in China since 2008, affecting more than one million children and causing several hundred children deaths every year. The pathogens of HFMD are mainly human enteroviruses (HEVs. Among them, human enterovirus 71 (HEV71 and coxsackievirus A16 (CVA16 are the most common pathogens of HFMD. However, other HEVs could also cause HFMD. To rapidly detect HEV71 and CVA16, and ensure detection of all HEVs causing HFMD, two real-time hybridization probe-based RT-PCR assays were developed in this study. One is a multiplex real-time RT-PCR assay, which was developed to detect and differentiate HEV71 specifically from CVA16 directly from clinical specimens within 1-2 h, and the other is a broad-spectrum real-time RT-PCR assay, which targeted almost all HEVs. The experiments confirmed that the two assays have high sensitivity and specificity, and the sensitivity was up to 0.1 TCID50/ml for detection of HEVs, HEV71, and CVA16, respectively. A total of 213 clinical specimens were simultaneously detected by three kinds of assays, including the two real-time RT-PCR assays, direct conventional RT-PCR assay, and virus isolation assay on human rhabdomyosarcoma cells (RD cells. The total positive rate of both HEV71 and CVA16 was 69.48% with real-time RT-PCR assay, 47.42% with RT-PCR assay, and 34.58% with virus isolation assay. One HFMD clinical specimen was positive for HEV, but negative for HEV71 or CVA16, which was identified as Echovirus 11 (Echo11 by virus isolation, RT-PCR, and sequencing for the VP1 gene. The two real-time RT-PCR assays had been applied in 31 provincial HFMD labs to detect the pathogens of HFMD, which has contributed to the rapid identification of the pathogens in the early stages of HFMD outbreaks, and helped to clarify the etiologic agents of HFMD in China.

  1. Safeguards and Non-destructive Assay

    International Nuclear Information System (INIS)

    Carchon, R.; Bruggeman, M.

    2001-01-01

    SCK-CEN's programme on safeguards and non-destructive assay includes: (1) various activities to assure nuclear materials accountancy; (2) contributes to the implementation of Integrated Safeguards measures in Belgium and to assist the IAEA through the Belgian Support Programme; (3) renders services to internal and external customers in the field of safeguards; (4) improves passive neutron coincidence counting techniques for waste assay and safeguards verification measurements by R and D on correlation algorithms implemented via software or dedicated hardware; (5) improves gamma assay techniques for waste assay by implementing advanced scanning techniques and different correlation algorithms; and (6) develops numerical calibration techniques. Major achievements in these areas in 2000 are reported

  2. Effective implementation of novel MET pharmacodynamic assays in translational studies.

    Science.gov (United States)

    Srivastava, Apurva K; Navas, Tony; Herrick, William G; Hollingshead, Melinda G; Bottaro, Donald P; Doroshow, James H; Parchment, Ralph E

    2017-01-01

    MET tyrosine kinase (TK) dysregulation is significantly implicated in many types of cancer. Despite over 20 years of drug development to target MET in cancers, a pure anti-MET therapeutic has not yet received market approval. The failure of two recently concluded phase III trials point to a major weakness in biomarker strategies to identify patients who will benefit most from MET therapies. The capability to interrogate oncogenic mutations in MET via circulating tumor DNA (ctDNA) provides an important advancement in identification and stratification of patients for MET therapy. However, a wide range in type and frequency of these mutations suggest there is a need to carefully link these mutations to MET dysregulation, at least in proof-of-concept studies. In this review, we elaborate how we can utilize recently developed and validated pharmacodynamic biomarkers of MET not only to show target engagement, but more importantly to quantitatively measure MET dysregulation in tumor tissues. The MET assay endpoints provide evidence of both canonical and non-canonical MET signaling, can be used as "effect markers" to define biologically effective doses (BEDs) for molecularly targeted drugs, confirm mechanism-of-action in testing combination of drugs, and establish whether a diagnostic test is reporting MET dysregulation. We have established standard operating procedures for tumor biopsy collections to control pre-analytical variables that have produced valid results in proof-of-concept studies. The reagents and procedures are made available to the research community for potential implementation on multiple platforms such as ELISA, quantitative immunofluorescence assay (qIFA), and immuno-MRM assays.

  3. Expression of Hepatitis C Virus Core and E2 antigenic recombinant proteins and their use for development of diagnostic assays.

    Science.gov (United States)

    Ali, Amjad; Nisar, Muhammad; Idrees, Muhammad; Rafique, Shazia; Iqbal, Muhammad

    2015-05-01

    Early diagnosis of HCV infection is based on detection of antibodies against HCV proteins using recombinant viral antigens. The present study was designed to select, clone and express the antigenic regions of Core and E2 genes from local HCV-3a genotype and to utilize the antigenic recombinant proteins (Core & E2) to develop highly sensitive, specific and economical diagnostic assays for detection of HCV infection. The antigenic sites were determined within Core and E2 genes and were then cloned in pET-28a expression vector. The right orientation of the desired inserted fragments of Core and E2 were confirmed via sequencing prior to expression and were then transformed in BL21 (DE3) pLysS strains of E. coli and induced with 0.5mM Isopropyl-b-D-thiogalactopyranoside (IPTG) for the production of antigenic recombinant proteins. The produced truncated antigens were then purified by Nickel affinity chromatography and were confirmed by western blotting, immunoblotting and enzyme-linked immunosorbent assay (ELISA). The expressed Core and E2 recombinant antigens were used to develop immunoblotting assay for the detection of anti-HCV antibodies in sera. With immunoblotting, a total of 93-HCV infected sera and 35-HCV negative individuals were tested for the presence of anti-HCV antibodies to the Core and E2 antigens. Recombinant antigen showed 100% reactivity against HCV infected sera, with no cross reactivity against HCV-negative sera. The immunoblot assay mixture of recombinant antigens (Core+E2) showed a strong reaction intensity in the test area (TA) as compared to the individual truncated Core and E2 recombinant antigens. In the in-house ELISA assay, mixed Core and E2 recombinant antigens showed 100% reactivity against a standardized panel of 150-HCV-positive sera and non reactivity against a standardized panel of 150 HCV-negative sera while also being non reactive to sera positive for other viral infections. The antigenic recombinant antigens also were tested for the

  4. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.

    Science.gov (United States)

    Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J

    2018-04-12

    False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  5. Bacteriologically confirmed tuberculosis in children

    International Nuclear Information System (INIS)

    Ozere, I.; Sele, A.; Ozolina, A.

    2005-01-01

    Tuberculosis in children and adults is a growing problem with important public health implications. In Latvia the incidence of tuberculosis (TB) in children up to age 14 has increased from 7,1 per 100000 in 1992 to 28,8 per 100000 in 2003. The diagnosis of TB is confirmed by isolation and identification of M. tuberculosis (MT) from clinical specimen. Confirmation of the disease, however, is difficult in children due to poor bacilli excretion and even under the best circumstances only about 30-40% of pediatric TB cases are proved bacteriologically. Of the 370 pediatric TB cases diagnosed between January 1, 2001 and December 1, 2003 in Latvia, 53 (14,3%) were confirmed bacteriologically. The clinical, radiological, immunological and anamnestic features of confirmed TB can serve as cornerstones for diagnosing of TB, when culture is not available. Objective To evaluate the sensitivity of diagnostic criteria of TB, clinical and radiological manifestation of TB and drug susceptibility of MT isolated also. Methods All consecutive children (53 in total) up to age 14 diagnosed with bacteriologically confirmed TB during 01.01.2001. -01.12.2003. were prospectively evaluated for reasons mentioned above. Results Of the 53 children identified all but one had respiratory tract TB. 17(32,1 %) children were under 4 years of age, 9 (17%) children were 5-9 years old, but 27 (50,9%) patients were 10-14 years old. During evaluation data on TB source case were found in addition in 13 children and total TB contact history was positive in 37 (69,8%) patients. All clinical and radiographical forms of respiratory tract TB were diagnosed. The most common encountered forms were intrathoracic adenopathy in 10 (18,9%) cases and TB pneumonia in 6 (11,3%) cases in children aged 10-14 years. lnthrathoracic adenopathy associated with segmental parenchymal lesion was the most common form in children under 4 years of age -7 (13,2%) cases respectively. Conclusions 1. The clinical and radiological

  6. Radioactive wastes assay technique and equipment

    International Nuclear Information System (INIS)

    Lee, K. M.; Hong, D. S; Kim, T. K.; Bae, S. M.; Shon, J. S.; Hong, K. P.

    2004-12-01

    The waste inventory records such as the activities and radio- nuclides contained in the waste packages are to be submitted with the radioactive wastes packages for the final disposal. The nearly around 10,000 drums of waste stocked in KAERI now should be assayed for the preparation of the waste inventory records too. For the successive execution of the waste assay, the investigation into the present waste assay techniques and equipment are to be taken first. Also the installation of the waste assay equipment through the comprehensive design, manufacturing and procurement should be proceeded timely. As the characteristics of the KAERI-stocked wastes are very different from that of the nuclear power plant and those have no regular waste streams, the application of the in-direct waste assay method using the scaling factors are not effective for the KAERI-generated wastes. Considering for the versal conveniency including the accuracy over the wide range of waste forms and the combination of assay time and sensitivity, the TGS(Tomographic Gamma Scanner) is appropriate as for the KAERI -generated radioactive waste assay equipment

  7. HPV 11, 16 and 18 DNA sequences in cervical swabs from women with cervical dysplasia: prevalence and associated risk of progression

    DEFF Research Database (Denmark)

    Hørding, U.; Daugaard, S.; Bock, J.E.

    1991-01-01

    Med.mikrobiologi, papillomavirus, cervical intraepithelial neoplasia, filter in situ hybridisation......Med.mikrobiologi, papillomavirus, cervical intraepithelial neoplasia, filter in situ hybridisation...

  8. Prevalence of human papillomavirus types 11, 16 and 18 in cervical swabs. A study of 1362 pregnant women

    DEFF Research Database (Denmark)

    Hørding, U.; Iversen, A.K.N.; Sebbelov, A.

    1990-01-01

    Med. mikrobiologi, papillomavirus, cervical intraepithelial neoplasia, filter in situ hybridisation......Med. mikrobiologi, papillomavirus, cervical intraepithelial neoplasia, filter in situ hybridisation...

  9. Real-Time Detection and Identification of Chlamydophila Species in Veterinary Specimens by Using SYBR Green-Based PCR Assays

    DEFF Research Database (Denmark)

    Nordentoft, Steen; Kabell, Susanne; Pedersen, Karl

    2011-01-01

    of Chlamydiaceae and differentiate the most prevalent veterinary Chlamydophila species: Cp. psittaci, Cp. abortus, Cp. felis, and Cp. caviae. By adding bovine serum albumin to the master mixes, target DNA could be detected directly in crude lysates of enzymatically digested conjunctival or pharyngeal swabs...... or tissue specimens from heart, liver, and spleen without further purification. The assays were evaluated on veterinary specimens where all samples were screened using a family-specific PCR, and positive samples were further tested using species-specific PCRs. Cp. psittaci was detected in 47 birds, Cp...... with a highly sensitive family-specific PCR, we were able to screen for Chlamydiaceae in veterinary specimens and confirm the species in positive samples with additional PCR assays....

  10. PERFORMANCE CONFIRMATION IN-SITU INSTRUMENTATION

    International Nuclear Information System (INIS)

    N.T. Raczka

    2000-01-01

    The purpose of this document is to identify and analyze the types of in-situ instruments and methods that could be used in support of the data acquisition portion of the Performance Confirmation (PC) program at the potential nuclear waste repository at Yucca Mountain. The PC program will require geomechanical , geophysical, thermal, and hydrologic instrumentation of several kinds. This analysis is being prepared to document the technical issues associated with each type of measurement during the PC period. This analysis utilizes the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a) as its starting point. The scope of this analysis is primarily on the period after the start of waste package emplacement and before permanent closure of the repository, a period lasting between 15 and 300 years after last package emplacement (Stroupe 2000, Attachment 1, p. 1). The primary objectives of this analysis are to: (1) Review the design criteria as presented in the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a). The scope of this analysis will be limited to the instrumentation related to parameters that require continuous monitoring of the conditions underground. (2) Preliminary identification and listing of the data requirements and parameters as related to the current repository layout in support of PC monitoring. (3) Preliminary identification of methods and instrumentation for the acquisition of the required data. Although the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a) defines a broad range of data that must be obtained from a variety of methods, the focus of this analysis is on instrumentation related to the performance of the rock mass and the formation of water in the repository environment, that is obtainable from in-situ observation, testing, and monitoring

  11. Radioactive waste package assay facility. Volume 1. Application of assay technology

    International Nuclear Information System (INIS)

    Findlay, D.J.S.; Green, T.H.; Molesworth, T.V.; Staniforth, D.; Strachan, N.R.; Rogers, J.D.; Wise, M.O.; Forrest, K.R.

    1992-01-01

    This report, in three volumes, covers the work carried out by Taylor Woodrow Construction Ltd., and two major sub-contractors: Harwell Laboratory (AEA Technology) and Siemens Plessey Controls Ltd., on the development of a radioactive waste package assay facility, for cemented 500 litre intermediate level waste drums. In volume 1, the reasons for assay are considered together with the various techniques that can be used, and the information that can be obtained. The practical problems associated with the use of the various techniques in an integrated assay facility are identified, and the key parameters defined. Engineering and operational features are examined and provisional designs proposed for facilities at three throughput levels: 15,000, 750 and 30 drums per year respectively. The capital and operating costs for such facilities have been estimated. A number of recommendations are made for further work. 16 refs., 14 figs., 13 tabs

  12. Development and application of a universal Hemoplasma screening assay based on the SYBR green PCR principle.

    Science.gov (United States)

    Willi, Barbara; Meli, Marina L; Lüthy, Ruedi; Honegger, Hanspeter; Wengi, Nicole; Hoelzle, Ludwig E; Reusch, Claudia E; Lutz, Hans; Hofmann-Lehmann, Regina

    2009-12-01

    Hemotropic mycoplasmas (hemoplasmas) are the causative agents of infectious anemia in several mammalian species. Their zoonotic potential has recently been substantiated by the identification of a feline hemoplasma isolate in an immunocompromised human patient. Although species-specific diagnostic molecular methods have been developed, their application as screening tools is limited due to the species diversity of hemoplasmas. The goals of this study were to develop a universal hemoplasma screening assay with broad specificity based on the SYBR green PCR principle, to compare the assay with hemoplasma-specific TaqMan PCR, and to analyze potential tick vectors and human blood samples to address the zoonotic potential. The newly developed PCR assay based on the 16S rRNA gene amplified feline, canine, bovine, porcine, camelid, and murine hemoplasmas, as well as Mycoplasma penetrans and Mycoplasma pneumoniae. The lower detection limit for feline and canine hemoplasmas was 1 to 10 copies/PCR. The assay exhibited 98.2% diagnostic sensitivity and 92.1% diagnostic specificity for feline hemoplasmas. All 1,950 Ixodes ticks were PCR negative, suggesting that Ixodes ticks are not relevant vectors for the above-mentioned hemoplasma species in Switzerland. None of the 414 blood samples derived from anemic or immunocompromised human patients revealed a clear positive result. The SYBR green PCR assay described here is a suitable tool to screen for known and so-far-undiscovered hemoplasma species. Positive results should be confirmed by specific TaqMan PCR or sequencing.

  13. Automation of the dicentric chromosome assay and related assays

    International Nuclear Information System (INIS)

    Balajee, Adayabalam S.; Dainiak, Nicholas

    2016-01-01

    Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed

  14. Recombinant immunoblot assay reaction patterns and hepatitis C virus RNA in blood donors and non-A, non-B hepatitis patients

    NARCIS (Netherlands)

    Bresters, D.; Zaaijer, H. L.; Cuypers, H. T.; Reesink, H. W.; Winkel, I. N.; van Exel-Oehlers, P. J.; van Drimmelen, A. A.; Jansen, P. L.; van der Poel, C. L.; Lelie, P. N.

    1993-01-01

    To establish the value of the second-generation recombinant immunoblot assay (RIBA-2) and cDNA polymerase chain reaction (cDNA PCR) for confirmation of hepatitis C virus (HCV) infection, anti-HCV reaction patterns and the presence of HCV RNA were examined in 610 blood donors and 255 non-A, non-B

  15. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  16. Harmonization of radiobiological assays: why and how?

    International Nuclear Information System (INIS)

    Prasanna, Pataje G.

    2014-01-01

    The International Atomic Energy Agency has made available a technical manual for cytogenetic biodosimetry assays (dicentric chromosome aberration (DCA) and cytokinesis-block micronucleus (CBMN) assays) used for radiation dose assessment in radiation accidents. The International Standardization Organization, which develops standards and guidelines, also provides an avenue for laboratory accreditation, has developed guidelines and recommendations for performing cytogenetic biodosimetry assays. Harmonization of DCA and CBMN assays, has improved their accuracy. Double-blinded inter-laboratory comparison studies involving several networks have further validated DCA and CBMN assays and improved the confidence in their potential use for radiation dose assessment in mass casualties. This kind of international harmonization is lacking for pre-clinical radiobiology assays. The widely used pre-clinical assays that are relatively important to set stage for clinical trials include clonogenic assays, flow-cytometry assays, apoptotic assays, and tumor regression and growth delay assays. However, significant inter-laboratory variations occur with respect to data among laboratories. This raises concerns on the reliability and reproducibility of preclinical data that drives further development and translation. Lack of reproducibility may stem from a variety of factors such as poor scientist training, less than optimal experimental design, inadequate description of methodology, and impulse to publish only the positive data etc. Availability of technical manuals, standard operating procedures, accreditation avenues for laboratories performing such assays, inter-laboratory comparisons, and use of standardized protocols are necessary to enhance reliability and reproducibility. Thus, it is important that radiobiological assays are harmonized for laboratory protocols to ensure successful translation of pre-clinical research on radiation effect modulators to help design clinic trials with

  17. Performance Confirmation Data Acquisition System

    International Nuclear Information System (INIS)

    D.W. Markman

    2000-01-01

    The purpose of this analysis is to identify and analyze concepts for the acquisition of data in support of the Performance Confirmation (PC) program at the potential subsurface nuclear waste repository at Yucca Mountain. The scope and primary objectives of this analysis are to: (1) Review the criteria for design as presented in the Performance Confirmation Data Acquisition/Monitoring System Description Document, by way of the Input Transmittal, Performance Confirmation Input Criteria (CRWMS M and O 1999c). (2) Identify and describe existing and potential new trends in data acquisition system software and hardware that would support the PC plan. The data acquisition software and hardware will support the field instruments and equipment that will be installed for the observation and perimeter drift borehole monitoring, and in-situ monitoring within the emplacement drifts. The exhaust air monitoring requirements will be supported by a data communication network interface with the ventilation monitoring system database. (3) Identify the concepts and features that a data acquisition system should have in order to support the PC process and its activities. (4) Based on PC monitoring needs and available technologies, further develop concepts of a potential data acquisition system network in support of the PC program and the Site Recommendation and License Application

  18. A New Way to Confirm Planet Candidates

    Science.gov (United States)

    Kohler, Susanna

    2016-05-01

    What was the big deal behind the Kepler news conference yesterday? Its not just that the number of confirmed planets found by Kepler has more than doubled (though thats certainly exciting news!). Whats especially interesting is the way in which these new planets were confirmed.Number of planet discoveries by year since 1995, including previous non-Kepler discoveries (blue), previous Kepler discoveries (light blue) and the newly validated Kepler planets (orange). [NASA Ames/W. Stenzel; Princeton University/T. Morton]No Need for Follow-UpBefore Kepler, the way we confirmed planet candidates was with follow-up observations. The candidate could be validated either by directly imaging (which is rare) or obtaining a large number radial-velocity measurements of the wobble of the planets host star due to the planets orbit. But once Kepler started producing planet candidates, these approaches to validation became less feasible. A lot of Kepler candidates are small and orbit faint stars, making follow-up observations difficult or impossible.This problem is what inspired the development of whats known as probabilistic validation, an analysis technique that involves assessing the likelihood that the candidates signal is caused by various false-positive scenarios. Using this technique allows astronomers to estimate the likelihood of a candidate signal being a true planet detection; if that likelihood is high enough, the planet candidate can be confirmed without the need for follow-up observations.A breakdown of the catalog of Kepler Objects of Interest. Just over half had previously been identified as false positives or confirmed as candidates. 1284 are newly validated, and another 455 have FPP of1090%. [Morton et al. 2016]Probabilistic validation has been used in the past to confirm individual planet candidates in Kepler data, but now Timothy Morton (Princeton University) and collaborators have taken this to a new level: they developed the first code thats designed to do fully

  19. MS transport assays for γ-aminobutyric acid transporters--an efficient alternative for radiometric assays.

    Science.gov (United States)

    Schmitt, Sebastian; Höfner, Georg; Wanner, Klaus T

    2014-08-05

    Transport assays for neurotransmitters based on radiolabeled substrates are widely spread and often indispensable in basic research and the drug development process, although the use of radioisotopes is inherently coupled to issues concerning radioactive waste and safety precautions. To overcome these disadvantages, we developed mass spectrometry (MS)-based transport assays for γ-aminobutyric acid (GABA), which is the major inhibitory neurotransmitter in the central nervous system (CNS). These "MS Transport Assays" provide all capabilities of [(3)H]GABA transport assays and therefore represent the first substitute for the latter. The performance of our approach is demonstrated for GAT1, the most important GABA transporter (GAT) subtype. As GABA is endogenously present in COS-7 cells employed as hGAT1 expression system, ((2)H6)GABA was used as a substrate to differentiate transported from endogenous GABA. To record transported ((2)H6)GABA, a highly sensitive, short, robust, and reliable HILIC-ESI-MS/MS quantification method using ((2)H2)GABA as an internal standard was developed and validated according to the Center for Drug Evaluation and Research (CDER) guidelines. Based on this LC-MS quantification, a setup to characterize hGAT1 mediated ((2)H6)GABA transport in a 96-well format was established, that enables automated processing and avoids any sample preparation. The K(m) value for ((2)H6)GABA determined for hGAT1 is in excellent agreement with results obtained from [(3)H]GABA uptake assays. In addition, the established assay format enables efficient determination of the inhibitory potency of GAT1 inhibitors, is capable of identifying those inhibitors transported as substrates, and furthermore allows characterization of efflux. The approach described here combines the strengths of LC-MS/MS with the high efficiency of transport assays based on radiolabeled substrates and is applicable to all GABA transporter subtypes.

  20. A prospective study of the prevalence of tuberculosis and bacteraemia in Bangladeshi children with severe malnutrition and pneumonia including an evaluation of Xpert MTB/RIF assay.

    Directory of Open Access Journals (Sweden)

    Mohammod Jobayer Chisti

    Full Text Available Severe malnutrition is a risk factor for pneumonia due to a wide range of pathogens but aetiological data are limited and the role of Mycobacterium tuberculosis is uncertain.We prospectively investigated severely malnourished young children (<5 years with radiological pneumonia admitted over a 15-month period. Investigations included blood culture, sputa for microscopy and mycobacterial culture. Xpert MTB/RIF assay was introduced during the study. Study children were followed for 12 weeks following their discharge from the hospital.405 eligible children were enrolled, with a median age of 10 months. Bacterial pathogens were isolated from blood culture in 18 (4.4% children, of which 72% were Gram negatives. Tuberculosis was confirmed microbiologically in 7% (27/396 of children that provided sputum - 10 by culture, 21 by Xpert MTB/RIF assay, and 4 by both tests. The diagnostic yield from induced sputum was 6% compared to 3.5% from gastric aspirate. Sixty (16% additional children had tuberculosis diagnosed clinically that was not microbiologically confirmed. Most confirmed tuberculosis cases did not have a positive contact history or positive tuberculin test. The sensitivity and specificity of Xpert MTB/RIF assay compared to culture was 67% (95% CI: 24-94 and 92% (95% CI: 87-95 respectively. Overall case-fatality rate was 17% and half of the deaths occurred in home following discharge from the hospital.TB was common in severely malnourished Bangladeshi children with pneumonia. X-pert MTB/RIF assay provided higher case detection rate compared to sputum microscopy and culture. The high mortality among the study children underscores the need for further research aimed at improved case detection and management for better outcomes.

  1. Clonogenic assay: adherent cells.

    Science.gov (United States)

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C

    2011-03-13

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 1956. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811). Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  2. Evaluation of a single-tube fluorogenic RT-PCR assay for detection of bovine respiratory syncytial virus in clinical samples

    DEFF Research Database (Denmark)

    Hakhverdyan, Mikhayil; Hägglund, Sara; Larsen, Lars Erik

    2005-01-01

    understanding of the virus. In this study, a BRSV fluorogenic reverse transcription PCR (fRT-PCR) assay, based on TaqMan principle, was developed and evaluated on a large number of clinical samples, representing various cases of natural and experimental BRSV infections. By using a single-step closed-tube format......, the turn-around time was shortened drastically and results were obtained with minimal risk for cross-contamination. According to comparative analyses, the detection limit of the fRT-PCR was on the same level as that of a nested PCR and the sensitivity relatively higher than that of a conventional PCR......, antigen ELISA (Ag-ELISA) and virus isolation (VI). Interspersed negative control samples, samples from healthy animals and eight symptomatically or genetically related viruses were all negative, confirming a high specificity of the assay. Taken together, the data indicated that the fRT-PCR assay can...

  3. A versatile method to design stem-loop primer-based quantitative PCR assays for detecting small regulatory RNA molecules.

    Directory of Open Access Journals (Sweden)

    Zsolt Czimmerer

    Full Text Available Short regulatory RNA-s have been identified as key regulators of gene expression in eukaryotes. They have been involved in the regulation of both physiological and pathological processes such as embryonal development, immunoregulation and cancer. One of their relevant characteristics is their high stability, which makes them excellent candidates for use as biomarkers. Their number is constantly increasing as next generation sequencing methods reveal more and more details of their synthesis. These novel findings aim for new detection methods for the individual short regulatory RNA-s in order to be able to confirm the primary data and characterize newly identified subtypes in different biological conditions. We have developed a flexible method to design RT-qPCR assays that are very sensitive and robust. The newly designed assays were tested extensively in samples from plant, mouse and even human formalin fixed paraffin embedded tissues. Moreover, we have shown that these assays are able to quantify endogenously generated shRNA molecules. The assay design method is freely available for anyone who wishes to use a robust and flexible system for the quantitative analysis of matured regulatory RNA-s.

  4. Adaptations in bacterial and fungal communities to termite fungiculture

    DEFF Research Database (Denmark)

    Otani, Saria

    in the bacterial and fungal communities. To do this, we used pyrosequencing, fluorescent in situ hybridisation, light and confocal microscopy, enzymatic assays, chemical extractions, in vitro assays, and feeding experiments in this thesis work to elucidate these predicted changes in fungus-growing termite...... in the proportion of fungal material provided to the cockroaches. However, gut microbiotas remained distinct from those of termites after Termitomyces-feeding, indicating that a fungal diet can play a role in structuring gut community composition, but at the same time exemplifies how original community compositions......, and possibly gut microenvironment constrain the magnitude of change. This thesis also characterises the fungus comb fungal communities (mycobiotas) in fungusgrowing termites, and shows that non-Termitomyces fungi were essentially absent in combs, and that Termitomyces fungal crops are maintained...

  5. Hybridisation of Education

    DEFF Research Database (Denmark)

    Tække, Jesper; Paulsen, Michael Eric

    This paper presents a new systems theoretical model about how we adequately can describe education on the level of the classroom after the introduction of digital media and wireless networks. For centuries school-classes has worked as walled educational interaction-systems, but now under influence...... of the digital revolution, they are populated with – and invaded by - cyborgs who can interrupt, contribute to, or initiate interaction systems that transcends the room’s four walls, making the educational situation more fragile, vulnerable and complex than ever. The paper discusses the phenomena with departure...... in the action research project Socio Media Education. We argue that the new cyborg-reality – i.e. complex of digital technology and human beings - turns education into a social hybrid. The main feature of this hybrid is a new nexus of the community (the social system), social networks (the social environment...

  6. Indeterminate human immunodeficiency virus western blot results in Iranian patients with discordant screening assay results

    International Nuclear Information System (INIS)

    Ravanshad, M.; Sabahi, F.; Mahboudi, F.; Sabahi, F.

    2006-01-01

    The Western blot (WB) assay is the most widely accepted confirmatory assay for the detection and confirmation of antibodies to human immunodeficiency virus type 1 (HIV-1) and 2 (HIV-2). However, indeterminate WB reactivity to HIV-1 and HIV-2 proteins may occur in individuals who do not appear to be infected with HIV. In this study, we describe the results of indeterminate WB reactivity in Iranian patients with discordant screening assays. The samples were obtained from Iranian Blood Transfusion Center, Tehran, Iran and evaluated in the Biotechnology Process Development Center, Pasteur Institute of Iran, Tehran, Iran between 2003 and 2004. A total of 4707 were tested for the presence of HIV-1 antibodies. Six hundred and four (12.8%) patients tested for HIV were positive for HIV-1 antibody. Nine (1.49%) have discordant results among screening assays and indeterminate WB results as interpreted by Centers for Disease Control and Prevention (CDC) criteria. Most (66.7%) of these indeterminate WB results were due to p24 reactivity. However, 2(22.2%) display reactivity to both gp41 and gp120 proteins [Positive by World Health Organization (WHO) criteria]. Of 9 WB assays initially indeterminate by the CDC criteria and with follow-up samples 8(88.8%) became negative when retested subsequently while one (11.1%) remained indeterminate for more than a year and were thus considered negative. In addition all the indeterminate samples were negative when assessed by polymerase chain reaction assay. In general, there were was an 88.8% concordance between the CDC and WHO criteria for an indeterminate WB result. The CDC II criteria for an indeterminate WB result. The CDC II criteria best met the specified objectives for diagnosis in our setting. (author)

  7. Population Differentiation and Hybridisation of Australian Snubfin (Orcaella heinsohni) and Indo-Pacific Humpback (Sousa chinensis) Dolphins in North-Western Australia

    Science.gov (United States)

    Brown, Alexander M.; Kopps, Anna M.; Allen, Simon J.; Bejder, Lars; Littleford-Colquhoun, Bethan; Parra, Guido J.; Cagnazzi, Daniele; Thiele, Deborah; Palmer, Carol; Frère, Celine H.

    2014-01-01

    strong evidence for the first documented case of hybridisation between a female snubfin dolphin and a male humpback dolphin. PMID:24988113

  8. Population differentiation and hybridisation of Australian snubfin (Orcaella heinsohni and Indo-Pacific humpback (Sousa chinensis dolphins in north-western Australia.

    Directory of Open Access Journals (Sweden)

    Alexander M Brown

    the first documented case of hybridisation between a female snubfin dolphin and a male humpback dolphin.

  9. Multicentre comparison of a diagnostic assay

    DEFF Research Database (Denmark)

    Waters, Patrick; Reindl, Markus; Saiz, Albert

    2016-01-01

    ) assays in neuromyelitis optica spectrum disorders (NMOSD). METHODS: Coded samples from patients with neuromyelitis optica (NMO) or NMOSD (101) and controls (92) were tested at 15 European diagnostic centres using 21 assays including live (n=3) or fixed cell-based assays (n=10), flow cytometry (n=4...

  10. An ultrafiltration assay for lysyl oxidase

    International Nuclear Information System (INIS)

    Shackleton, D.R.; Hulmes, D.J.

    1990-01-01

    A modification of the original microdistillation assay for lysyl oxidase is described in which Amicon C-10 microconcentrators are used to separate, by ultrafiltration, the 3H-labeled products released from a [4,5-3H]-lysine-labeled elastin substrate. Enzyme activity is determined by scintillation counting of the ultrafiltrate, after subtraction of radioactivity released in the presence of beta-aminopropionitrile, a specific inhibitor of the enzyme. Conditions are described which optimize both the sensitivity and the efficient use of substrate. The assay shows linear inhibition of activity in up to 1 M urea; hence, as the enzyme is normally diluted in the assay, samples in 6 M urea can be assayed directly, without prior dialysis, and corrected for partial inhibition. Comparable results are obtained when enzyme activity is assayed by ultrafiltration or microdistillation. The assay is simple and convenient and, by using disposable containers throughout, it eliminates the need for time-consuming decontamination of radioactive glassware

  11. Direct enzyme assay evidence confirms aldehyde reductase function of Ydr541cp and Ygl039wp from Saccharomyces cerevisiae.

    Science.gov (United States)

    Moon, Jaewoong; Liu, Z Lewis

    2015-04-01

    The aldehyde reductase gene ARI1 is a recently characterized member of an intermediate subfamily within the short-chain dehydrogenase/reductase (SDR) superfamily that clarified mechanisms of in situ detoxification of 2-furaldehyde and 5-hydroxymethyl-2-furaldehyde by Saccharomyces cerevisiae. Uncharacterized open reading frames (ORFs) are common among tolerant candidate genes identified for lignocellulose-to-advanced biofuels conversion. This study presents partially purified proteins of two ORFs, YDR541C and YGL039W, and direct enzyme assay evidence against aldehyde-inhibitory compounds commonly encountered during lignocellulosic biomass fermentation processes. Each of the partially purified proteins encoded by these ORFs showed a molecular mass of approximately 38 kDa, similar to Ari1p, a protein encoded by aldehyde reductase gene. Both proteins demonstrated strong aldehyde reduction activities toward 14 aldehyde substrates, with high levels of reduction activity for Ydr541cp toward both aromatic and aliphatic aldehydes. While Ydr541cp was observed to have a significantly higher specific enzyme activity at 20 U/mg using co-factor NADPH, Ygl039wp displayed a NADH preference at 25 U/mg in reduction of butylaldehyde. Amino acid sequence analysis identified a characteristic catalytic triad, Ser, Tyr and Lys; a conserved catalytic motif of Tyr-X-X-X-Lys; and a cofactor-binding sequence motif, Gly-X-X-Gly-X-X-Ala, near the N-terminus that are shared by Ydr541cp, Ygl039wp, Yol151wp/GRE2 and Ari1p. Findings of aldehyde reductase genes contribute to the yeast gene annotation and aids development of the next-generation biocatalyst for advanced biofuels production. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Comparison of liquid based cytology and histology for the evaluation of HER-2 status using immunostaining and CISH in breast carcinoma.

    Science.gov (United States)

    Sartelet, H; Lagonotte, E; Lorenzato, M; Duval, I; Lechki, C; Rigaud, C; Cucherousset, J; Durlach, A; Graesslin, O; Abboud, P; Doco-Fenzy, M; Quereux, C; Costa, B; Polette, M; Munck, J-N; Birembaut, P

    2005-08-01

    HER-2 amplification is an important prognostic biomarker and treatment determinant in breast carcinoma. To correlate immunocytochemical (ICC) expression of HER-2 and gene amplification determined by chromogenic in situ hybridisation (CISH) using liquid based cytology (LBC) with immunohistochemistry (IHC) and CISH using histological samples of the same breast carcinomas. Frozen sections and cytobrushings of 103 breast carcinomas were analysed. Four techniques were performed on each tumour: two on LBC samples (ICC, and CISH, both graded as positive, indeterminate, or negative) and two on histological samples (IHC and CISH). Two cell lines (MCF-7, negative; BT 474, positive) were used as controls for cytological analysis. A complementary fluorescence in situ hybridisation technique was carried out in histological samples with low amplification (4-10 dots/nucleus). Interobserver agreement for the four techniques calculated by the kappa coefficient indicated a substantial agreement. Nine cases failed in cytology because of poor cellularity. Among 94 cases, 19 were amplified; 73, 12, and 9 tumours were scored 0 or 1+, 2+, and 3+, respectively by IHC and 75, 13, and 6, respectively, by ICC. CISH found no amplification in 72 tumours. Correlations between the IHC and CISH results in the histological and cytological samples were always significant. Her-2 status could be determined in LBC samples and correlated well with reference histological methods using in situ hybridisation. ICC was less reliable because of the presence of the cytoplasmic membrane. However, these results should be confirmed by a large multicentre study.

  13. False-Positive TDxFLx urine Amphetamine/Metamphetamine II assay from Ofloxacin

    International Nuclear Information System (INIS)

    Nomier, Mahmoud A.; Al-Huseini, Hani K.

    2004-01-01

    Immunoassays are widely used in testing urine for illicit drugs. Ofloaxcin and a number of other quinolones were found to induce false-positive opiates (OP) urine immunoassays. This can result in misleading conclusions in the concept of drug abuse The aim of present study was to evaluate the effects of ofloxacin in theraputic doses on the induction of false-positive urine immunoassays for common drugs of abuse in healthy male volunteers. The study was conducted on 6 healthy male volunteers, aging between 35-45 years. Two doses of 400 mg ofloxacin each, were given orally to each volunteer at 12 hours interval and urine samples were collected before ofloaxcin administration and 5-7.5 hours after the second dose. Urine samples were subjected for OP, amphetamine/methamphetamine II (AM/MA II), cocaine and cannabinoids assays on TDxFLx analyzer. Ofloxacin produced significant increase (P cutoff) for AM/MA II assays, were found in all volunteers after ofloaxcin administration. The study recomends strongly the confirmation of positive urine immunoassay results for drugs of abuseby a more specific methodology e.g. gas chromatography/ mass spectroscopy (GC/MS). (author)

  14. Competitive immunochromatographic assay for the detection of the organophosphorus pesticide chlorpyrifos

    Science.gov (United States)

    Kim, Young Ah; Lee, Eun-Hye; Kim, Kwang-Ok; Lee, Yong Tae; Hammock, Bruce D.; Lee, Hye-Sung

    2014-01-01

    An immunochromatographic assay (ICA) based on competitive antigen-coated format using colloidal gold as the label was developed for the detection of the organophosphorus insecticide chlorpyrifos. The ICA test strip consisted of a membrane with a detection zone, a sample pad and an absorbent pad. The membrane was separately coated with chlorpyrifos hapten-OVA conjugate (test line) and anti-mouse IgG (control line). Based on the fact that the competition is between the migrating analyte in the sample and the analyte hapten immobilized on the test strip for the binding sites of the antibody-colloidal gold (Ab-CG) conjugate migrating on the test strip, this study suggests that the relative migration speed between the two migrating substances is a critically important factor for the sensitive detection by competitive ICA. This criterion was utilized for the confirmation of appropriateness of a nitrocellulose (NC) membrane for chlorpyrifos ICA. The detection limit of the ICA for chlorpyrifos standard and chlorpyrifos spiked into agricultural samples were 10 and 50 ng mL−1, respectively. The assay time for the ICA test was less than 10 min, suitable for rapid on-site testing of chlorpyrifos. PMID:21504817

  15. Application of the DNA comet assay for detection of irradiated meat

    International Nuclear Information System (INIS)

    Kruszewski, M.; Iwanenko, T.; Wojewodzka, M.; Malec-Czechowska, K.; Dancewicz, A. M.; Szot, Z.

    1998-01-01

    Radiation induces damage to the DNA. This damage (fragmentation) can be assessed in the irradiated food using Single Cell Gel Electrophoresis (SCGE), known as DNA comet assay. Fragmentation of DNA may also be caused by improper storage of meat and repeated freezing and thawing. This makes identification of irradiated meat by this assay not reliable enough. In order to know the scale of the processes imitating radiation effects in DNA of the comets, their shape and lengths were examined in both irradiated and unirradiated fresh meat (D = 1.5 or 3.0 kGy) stored at 4 o C or frozen (-21 o ) up to 5 months. Comets formed upon SCGE were stained with DAPI or silver and examined in fluorescent or light microscope. They were divided arbitrarily into 4 classes. Comets of IV class were found quite often in fresh meat stored at 4 o C. In meat samples that were irradiated and stored frozen, comets of class I, II and III were observed. The negative comet test is univocal. Positive comet test, however, needs confirmation. The meat should be subjected to further analysis with other validated methods. (author)

  16. Scrapping of student bursaries confirmed.

    Science.gov (United States)

    Longhurst, Chris

    2016-07-27

    Student bursaries for nurses will be scrapped from next year, the government has confirmed. Undergraduate nursing and midwifery students in England will now face tuition fees and student loans from August 2017.

  17. Radioreceptor assay for insulin

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazuo [Tokyo Univ. (Japan). Faculty of Medicine

    1975-04-01

    Radioreceptor assay of insulin was discussed from the aspects of the measuring method, its merits and problems to be solved, and its clinical application. Rat liver 10 x g pellet was used as receptor site, and enzymatic degradation of insulin by the system contained in this fraction was inhibited by adding 1 mM p-CMB. /sup 125/I-labelled porcine insulin was made by lactoperoxidase method under overnight incubation at 4/sup 0/C and later purification by Sephadex G-25 column and Whatman CF-11 cellulose powder. Dog pancreatic vein serum insulin during and after the glucose load was determined by radioreceptor assay and radioimmunoassay resulting that both measurements accorded considerably. Radioreceptor assay would clarify the pathology of disorders of glucose metabolism including diabetes.

  18. Fluorescent Receptor Binding Assay for Detecting Ciguatoxins in Fish.

    Science.gov (United States)

    Hardison, D Ransom; Holland, William C; McCall, Jennifer R; Bourdelais, Andrea J; Baden, Daniel G; Darius, H Taiana; Chinain, Mireille; Tester, Patricia A; Shea, Damian; Quintana, Harold A Flores; Morris, James A; Litaker, R Wayne

    2016-01-01

    Ciguatera fish poisoning is an illness suffered by > 50,000 people yearly after consumption of fish containing ciguatoxins (CTXs). One of the current methodologies to detect ciguatoxins in fish is a radiolabeled receptor binding assay (RBA(R)). However, the license requirements and regulations pertaining to radioisotope utilization can limit the applicability of the RBA(R) in certain labs. A fluorescence based receptor binding assay (RBA(F)) was developed to provide an alternative method of screening fish samples for CTXs in facilities not certified to use radioisotopes. The new assay is based on competition binding between CTXs and fluorescently labeled brevetoxin-2 (BODIPY®-PbTx-2) for voltage-gated sodium channel receptors at site 5 instead of a radiolabeled brevetoxin. Responses were linear in fish tissues spiked from 0.1 to 1.0 ppb with Pacific ciguatoxin-3C (P-CTX-3C) with a detection limit of 0.075 ppb. Carribean ciguatoxins were confirmed in Caribbean fish by LC-MS/MS analysis of the regional biomarker (C-CTX-1). Fish (N = 61) of six different species were screened using the RBA(F). Results for corresponding samples analyzed using the neuroblastoma cell-based assay (CBA-N2a) correlated well (R2 = 0.71) with those of the RBA(F), given the low levels of CTX present in positive fish. Data analyses also showed the resulting toxicity levels of P-CTX-3C equivalents determined by CBA-N2a were consistently lower than the RBA(F) affinities expressed as % binding equivalents, indicating that a given amount of toxin bound to the site 5 receptors translates into corresponding lower cytotoxicity. Consequently, the RBA(F), which takes approximately two hours to perform, provides a generous estimate relative to the widely used CBA-N2a which requires 2.5 days to complete. Other RBA(F) advantages include the long-term (> 5 years) stability of the BODIPY®-PbTx-2 and having similar results as the commonly used RBA(R). The RBA(F) is cost-effective, allows high sample

  19. Fluorescent Receptor Binding Assay for Detecting Ciguatoxins in Fish.

    Directory of Open Access Journals (Sweden)

    D Ransom Hardison

    Full Text Available Ciguatera fish poisoning is an illness suffered by > 50,000 people yearly after consumption of fish containing ciguatoxins (CTXs. One of the current methodologies to detect ciguatoxins in fish is a radiolabeled receptor binding assay (RBA(R. However, the license requirements and regulations pertaining to radioisotope utilization can limit the applicability of the RBA(R in certain labs. A fluorescence based receptor binding assay (RBA(F was developed to provide an alternative method of screening fish samples for CTXs in facilities not certified to use radioisotopes. The new assay is based on competition binding between CTXs and fluorescently labeled brevetoxin-2 (BODIPY®-PbTx-2 for voltage-gated sodium channel receptors at site 5 instead of a radiolabeled brevetoxin. Responses were linear in fish tissues spiked from 0.1 to 1.0 ppb with Pacific ciguatoxin-3C (P-CTX-3C with a detection limit of 0.075 ppb. Carribean ciguatoxins were confirmed in Caribbean fish by LC-MS/MS analysis of the regional biomarker (C-CTX-1. Fish (N = 61 of six different species were screened using the RBA(F. Results for corresponding samples analyzed using the neuroblastoma cell-based assay (CBA-N2a correlated well (R2 = 0.71 with those of the RBA(F, given the low levels of CTX present in positive fish. Data analyses also showed the resulting toxicity levels of P-CTX-3C equivalents determined by CBA-N2a were consistently lower than the RBA(F affinities expressed as % binding equivalents, indicating that a given amount of toxin bound to the site 5 receptors translates into corresponding lower cytotoxicity. Consequently, the RBA(F, which takes approximately two hours to perform, provides a generous estimate relative to the widely used CBA-N2a which requires 2.5 days to complete. Other RBA(F advantages include the long-term (> 5 years stability of the BODIPY®-PbTx-2 and having similar results as the commonly used RBA(R. The RBA(F is cost-effective, allows high sample

  20. Validation of a norovirus multiplex real-time RT-PCR assay for the detection of norovirus GI and GII from faeces samples.

    LENUS (Irish Health Repository)

    Jones, S

    2011-01-01

    Norovirus is a leading cause of infectious non-bacterial gastroenteritis. The virus is highly contagious and has multiple modes of transmission, presenting a growing challenge to hospital-based healthcare. In this study, a total of 120 stool samples are tested for the presence of norovirus GI and GII by the Roche two-step Lightcycler 2.0 assay incorporating primers and probes produced by TIB Molbiol, and the results are compared with results from the National Virus Reference Laboratory. The Roche\\/TIB Molbiol assay produced 51 positive results and 69 negative results. Discrepancy analysis was performed for six conflicting results using a second real-time polymerase chain reaction (PCR) assay (Roche\\/TIB Molbiol) and this confirmed that four of the five discrepant positive results were true positives. A single discrepant negative result generated by the Roche assay remained negative using the second assay. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated to be 98%, 98.6%, 98.0% and 98.6%, respectively. Melting curve analysis was used to differentiate genogroups I and II and this showed that 92% of strains belonged to genogroup II.

  1. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  2. Nano-immunosafety: issues in assay validation

    International Nuclear Information System (INIS)

    Boraschi, Diana; Italiani, Paola; Oostingh, Gertie J; Duschl, Albert; Casals, Eudald; Puntes, Victor F; Nelissen, Inge

    2011-01-01

    Assessing the safety of engineered nanomaterials for human health must include a thorough evaluation of their effects on the immune system, which is responsible for defending the integrity of our body from damage and disease. An array of robust and representative assays should be set up and validated, which could be predictive of the effects of nanomaterials on immune responses. In a trans-European collaborative work, in vitro assays have been developed to this end. In vitro tests have been preferred for their suitability to standardisation and easier applicability. Adapting classical assays to testing the immunotoxicological effects of nanoparticulate materials has raised a series of issues that needed to be appropriately addressed in order to ensure reliability of results. Besides the exquisitely immunological problem of selecting representative endpoints predictive of the risk of developing disease, assay results turned out to be significantly biased by artefactual interference of the nanomaterials or contaminating agents with the assay protocol. Having addressed such problems, a series of robust and representative assays have been developed that describe the effects of engineered nanoparticles on professional and non-professional human defence cells. Two of such assays are described here, one based on primary human monocytes and the other employing human lung epithelial cells transfected with a reporter gene.

  3. Data transformation methods for multiplexed assays

    Science.gov (United States)

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2013-07-23

    Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.

  4. Immunoradiometric assay for the determination of E. coli proteins in recombinant dna derived human growth hormone produced at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Soares, Carlos R.J.

    1995-01-01

    An immunoradiometric assay (IRMA) for the determination of multiple antigens was set up in order to quantify E. coli (ECP) in lots of purified recombinant human growth hormone (rec-hGH). SDS-PAGE and Western Blotting techniques were carried out, in parallel, to confirm the results obtained by IRMA and to provide more information about the contaminants. Anti-ECP antibodies were obtained by rabbit immunization with ECP, which were submitted to the same purification process utilized for rec-hGH with the exception of the last step. A strain-process-specific assay was thus set up. The antiserum obtained was purified through an affinity column prepared with the same ECP used for immunization, this provided an highly sensitive assay (0,03 ng ECP/mL). This IRMA was shown to be specific, not presenting any cross reaction with hGH and studies carried out on precision, accuracy and linearity of response with dilution confirmed its validity as one of the fundamental purity tests for rec-hGH produced at IPEN-CNEN/SP, whose principles can be easily extended to the analysis of other similar products. These studies have also shown that the utilization of an affinity column, prepared with the described anti-ECP antiserum was very effective, providing rec-hGH lots with less then 10 parts per million (0,001%) of contaminating proteins. (author). 45 refs., 15 figs., 11 tabs

  5. High-throughput screening using pseudotyped lentiviral particles: a strategy for the identification of HIV-1 inhibitors in a cell-based assay.

    Science.gov (United States)

    Garcia, Jean-Michel; Gao, Anhui; He, Pei-Lan; Choi, Joyce; Tang, Wei; Bruzzone, Roberto; Schwartz, Olivier; Naya, Hugo; Nan, Fa-Jun; Li, Jia; Altmeyer, Ralf; Zuo, Jian-Ping

    2009-03-01

    Two decades after its discovery the human immunodeficiency virus (HIV) is still spreading worldwide and killing millions. There are 25 drugs formally approved for HIV currently on the market, but side effects as well as the emergence of HIV strains showing single or multiple resistances to current drug-therapy are causes for concern. Furthermore, these drugs target only 4 steps of the viral cycle, hence the urgent need for new drugs and also new targets. In order to tackle this problem, we have devised a cell-based assay using lentiviral particles to look for post-entry inhibitors of HIV-1. We report here the assay development, validation as well as confirmation of the hits using both wild-type and drug-resistant HIV-1 viruses. The screening was performed on an original library, rich in natural compounds and pure molecules from Traditional Chinese Medicine pharmacopoeia, which had never been screened for anti-HIV activity. The identified hits belong to four chemical sub-families that appear to be all non-nucleoside reverse transcriptase inhibitors (NNRTIs). Secondary tests with live viruses showed that there was good agreement with pseudotyped particles, confirming the validity of this approach for high-throughput drug screens. This assay will be a useful tool that can be easily adapted to screen for inhibitors of viral entry.

  6. Development and validation of cell-based luciferase reporter gene assays for measuring neutralizing anti-drug antibodies against interferon beta.

    Science.gov (United States)

    Hermanrud, Christina; Ryner, Malin; Luft, Thomas; Jensen, Poul Erik; Ingenhoven, Kathleen; Rat, Dorothea; Deisenhammer, Florian; Sørensen, Per Soelberg; Pallardy, Marc; Sikkema, Dan; Bertotti, Elisa; Kramer, Daniel; Creeke, Paul; Fogdell-Hahn, Anna

    2016-03-01

    Neutralizing anti-drug antibodies (NAbs) against therapeutic interferon beta (IFNβ) in people with multiple sclerosis (MS) are measured with cell-based bioassays. The aim of this study was to redevelop and validate two luciferase reporter-gene bioassays, LUC and iLite, using a cut-point approach to identify NAb positive samples. Such an approach is favored by the pharmaceutical industry and governmental regulatory agencies as it has a clear statistical basis and overcomes the limitations of the current assays based on the Kawade principle. The work was conducted following the latest assay guidelines. The assays were re-developed and validated as part of the "Anti-Biopharmaceutical Immunization: Prediction and analysis of clinical relevance to minimize the risk" (ABIRISK) consortium and involved a joint collaboration between four academic laboratories and two pharmaceutical companies. The LUC assay was validated at Innsbruck Medical University (LUCIMU) and at Rigshospitalet (LUCRH) Copenhagen, and the iLite assay at Karolinska Institutet, Stockholm. For both assays, the optimal serum sample concentration in relation to sensitivity and recovery was 2.5% (v/v) in assay media. A Shapiro-Wilk test indicated a normal distribution for the majority of runs, allowing a parametric approach for cut-point calculation to be used, where NAb positive samples could be identified with 95% confidence. An analysis of means and variances indicated that a floating cut-point should be used for all assays. The assays demonstrated acceptable sensitivity for being cell-based assays, with a confirmed limit of detection in neat serum of 1519 ng/mL for LUCIMU, 814 ng/mL for LUCRH, and 320 ng/mL for iLite. Use of the validated cut-point assay, in comparison with the previously used Kawade method, identified 14% more NAb positive samples. In conclusion, implementation of the cut-point design resulted in increased sensitivity to detect NAbs. However, the clinical significance of these low

  7. Spectrophotometric Enzyme Assays for High-Throughput Screening

    Directory of Open Access Journals (Sweden)

    Jean-Louis Reymond

    2004-01-01

    Full Text Available This paper reviews high-throughput screening enzyme assays developed in our laboratory over the last ten years. These enzyme assays were initially developed for the purpose of discovering catalytic antibodies by screening cell culture supernatants, but have proved generally useful for testing enzyme activities. Examples include TLC-based screening using acridone-labeled substrates, fluorogenic assays based on the β-elimination of umbelliferone or nitrophenol, and indirect assays such as the back-titration method with adrenaline and the copper-calcein fluorescence assay for aminoacids.

  8. Radioenzymatic assay of DOPA (3,4-dihydroxyphenylalanine)

    International Nuclear Information System (INIS)

    Johnson, G.A.; Gren, J.M.; Kupiecki, R.

    1978-01-01

    We modified the single-isotope radioenzymatic assay for catecholamines [Life Sci. 21, 625(1977)] to assay 3,4-dihydroxyphenylalanine (DOPA). DOPA decarboxylase is used to convert DOPA to dopamine, which concurrently is converted to [ 3 H]-3-O-methyldopamine in the presence of catechol-O-methyltransferase and [methyl- 3 H]-S-adenosylmethionine and assayed radioenzymatically. For assay of plasma DOPA, 50 μl of untreated plasma is added directly into the incubation mixture. A duplicate mixture containing an internal standard requires a second 50-μl aliquot of plasma. Because the assay measures both DOPA and endogenous dopamine, two additional aliquots of plasma must be assayed for dopamine in the absence of the decarboxylase by the differential assay; DOPA is estimated by difference. The assay is sensitive to 25 pg (500 ng/liter of plasma). Analysis of DOPA (DOPA plus dopamine) and the concurrent differential assay of catecholamines in at least 10 samples can be done in a single working day. Plasma DOPA concentrations for 42 normotensive adults were 1430 +- 19 ng/liter (mean +- SEM). In contrast, dopamine concentrations for these same subjects averaged 23 +- 20 ng/liter. Values for the 24 women subjects (1510 +- 62 ng/liter) significantly (P = 0.04) exceeded those for the men

  9. RAS - Screens & Assays - Drug Discovery

    Science.gov (United States)

    The RAS Drug Discovery group aims to develop assays that will reveal aspects of RAS biology upon which cancer cells depend. Successful assay formats are made available for high-throughput screening programs to yield potentially effective drug compounds.

  10. Field and laboratory evidence that Bungowannah virus, a recently recognised pestivirus, is the causative agent of the porcine myocarditis syndrome (PMC).

    Science.gov (United States)

    Finlaison, Deborah S; King, Katherine R; Frost, Melinda J; Kirkland, Peter D

    2009-05-12

    In 2003 an outbreak of sudden deaths occurred in 2-3-week-old piglets on a piggery in New South Wales, Australia. There was a marked increase in the birth of stillborn piglets and preweaning losses associated with a multifocal non-suppurative myocarditis with myonecrosis. The aim of this study was to review existing data and to undertake further investigations of specimens from naturally infected pigs to provide evidence to support the hypothesis that Bungowannah virus, a recently recognised pestivirus, causes the porcine myocarditis syndrome (PMC). Sera collected from gilts and sows from affected and unaffected units were tested for Bungowannah virus antibody by a peroxidase-linked assay and Bungowannah virus RNA by qRT-PCR in selected cases. Stillborn piglets from affected and an unaffected unit were also tested for Bungowannah virus antibody and RNA. Body fluid IgG levels and the incidence of myocardial lesions in these stillborn piglets are summarised. Tissue sections from stillborn piglets with myocarditis/myonecrosis were examined for Bungowannah virus RNA by in situ hybridisation. A clear temporal association between the occurrence of PMC on a unit or module and exposure to Bungowannah virus was identified by serological tests in both breeding aged animals and stillborn pigs. In addition, at the individual animal level on affected units, Bungowannah virus RNA was detected in stillborn piglets in large amounts by qRT-PCR and in association with myocardial lesions by in situ hybridisation. The examination of field material from cases of PMC by serology, qRT-PCR and in situ hybridisation provides strong indirect evidence that Bungowannah virus is the causative agent for PMC.

  11. The fluorometric microculture cytotoxicity assay.

    Science.gov (United States)

    Lindhagen, Elin; Nygren, Peter; Larsson, Rolf

    2008-01-01

    The fluorometric microculture cytotoxicity assay (FMCA) is a nonclonogenic microplate-based cell viability assay used for measurement of the cytotoxic and/or cytostatic effect of different compounds in vitro. The assay is based on hydrolysis of the probe, fluorescein diacetate (FDA) by esterases in cells with intact plasma membranes. The assay is available as both a semiautomated 96-well plate setup and a 384-well plate version fully adaptable to robotics. Experimental plates are prepared with a small amount of drug solution and can be stored frozen. Cells are seeded on the plates and cell viability is evaluated after 72 h. The protocol described here is applicable both for cell lines and freshly prepared tumor cells from patients and is suitable both for screening in drug development and as a basis for a predictive test for individualization of anticancer drug therapy.

  12. Solution assay instrument operations manual

    International Nuclear Information System (INIS)

    Li, T.K.; Marks, T.; Parker, J.L.

    1983-09-01

    An at-line solution assay instrument (SAI) has been developed and installed in a plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument was designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and americium/plutonium ratios and for routine operation by process technicians who lack instrumentation background. The SAI, based on transmission-corrected, high-resolution gamma-ray spectroscopy, has two measurement stations attached to a single multichannel analyzer/computer system. To ensure the quality of assay results, the SAI has an internal measurement control program, which requires daily and weekly check runs and monitors key aspects of all assay runs. For a 25-ml sample, the assay precision is 5 g/l within a 2000-s count time

  13. Making transuranic assay measurements using modern controllers

    International Nuclear Information System (INIS)

    Kuckertz, T.H.; Caldwell, J.T.; Medvick, P.A.; Kunz, W.E.; Hastings, R.D.

    1987-01-01

    This paper describes methodology and computer-controlled instrumentation developed at the Los Alamos National Laboratory that accurately performs nondestructive assays of large containers bearing transuranic wastes and nonradioactive matrix materials. These assay systems can measure fissile isotopes with 1-mg sensitivity and spontaneous neutron-emitting isotopes at a 10-mg sensitivity. The assays are performed by neutron interrogation, detection, and counting in a custom assay chamber. An International Business Machines Personal Computer (IBM-PC) is used to control the CAMAC-based instrumentation system that acquires the assay data. 6 refs., 7 figs

  14. Time-resolved immunofluorometric assay of serum ferritin

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Yao [China Inst. of Atomic Energy, Beijing (China)

    2007-06-15

    This assay is a solid phase, two-site fluoroimmunometric assay based on the direct sandwish technique. Standards or samples containing ferritin are first reacted with immobilized anti-ferritin antibodies. Then the europium-lablled antibodies are reacted with the bound antigen. The range of this assay is 2-1000 ng/mL. The analytical sentivity is better than 0.05 ng/mL. The intra-assay variation and inter-assay variation are both below 5%; This kit was compared with Wallac DELFIA kit. The correlation is r=0.96. (authors)

  15. Selective enrichment of volatiles confirmed

    Science.gov (United States)

    de Pater, Imke

    2018-05-01

    Hydrogen sulfide gas is detected above Uranus's main cloud deck, confirming the prevalence of H2S ice particles as the main cloud component and a strongly unbalanced nitrogen/sulfur ratio in the planet's deep atmosphere.

  16. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  17. Association tests and software for copy number variant data

    Directory of Open Access Journals (Sweden)

    Plagnol Vincent

    2009-01-01

    Full Text Available Abstract Recent studies have suggested that copy number variation (CNV significantly contributes to genetic predisposition to several common disorders. These findings, combined with the imperfect tagging of CNVs by single nucleotide polymorphisms (SNPs, have motivated the development of association studies directly targeting CNVs. Several assays, including comparative genomic hybridisation arrays, SNP genotyping arrays, or DNA quantification through real-time polymerase chain reaction analysis, allow direct assessment of CNV status in cohorts sufficiently large to provide adequate statistical power for association studies. When analysing data provided by these assays, association tests for CNV data are not fundamentally different from SNP-based association tests. The main difference arises when the quality of the CNV assay is not sufficient to convert unequivocally the raw measurement into discrete calls -- a common issue, given the technological limitations of current CNV assays. When this is the case, association tests are more appropriately based on the raw continuous measurement provided by the CNV assay, instead of potentially inaccurate discrete calls, thus motivating the development of new statistical methods. Here, the programs available for CNV association testing for case control or family data are reviewed, using either discrete calls or raw continuous data.

  18. Analysis and confirmation of synthetic anorexics in adulterated traditional Chinese medicines by high-performance capillary electrophoresis.

    Science.gov (United States)

    Ku, Y R; Chang, Y S; Wen, K C; Ho, L K

    1999-07-02

    Six synthetic anorexics, clobenzorex, diethylpropion, fenfluramine, methamphetamine, phenylpropanolamine and phentermine, which can be found as adulterants in traditional Chinese medicines were assayed simultaneously by high-performance capillary electrophoresis. The electrolyte was a buffer solution containing 120 mM phosphate buffer (NaH2PO4/H3PO4, pH 2.0) and 15% acetonitrile. Applied voltage was 16 kV and temperature was 30 degrees C. Fluoren-2,7-diammonium chloride was used as an internal standard and detector set at 200 nm. The recoveries of the synthetic anorexic adulterants in traditional Chinese medicinal formula using C8-SCX mixed solid-phase extraction were studied. Several traditional Chinese medicinal powders obtained from clinics were also studied by the above HPCE method and confirmed by GC-MS. Clobenzorex, diethylpropion and fenfluramine were found and determine in these samples.

  19. A Prospective Study of the Prevalence of Tuberculosis and Bacteraemia in Bangladeshi Children with Severe Malnutrition and Pneumonia Including an Evaluation of Xpert MTB/RIF Assay

    Science.gov (United States)

    Chisti, Mohammod Jobayer; Graham, Stephen M.; Duke, Trevor; Ahmed, Tahmeed; Ashraf, Hasan; Faruque, Abu Syed Golam; La Vincente, Sophie; Banu, Sayera; Raqib, Rubhana; Salam, Mohammed Abdus

    2014-01-01

    Background Severe malnutrition is a risk factor for pneumonia due to a wide range of pathogens but aetiological data are limited and the role of Mycobacterium tuberculosis is uncertain. Methods We prospectively investigated severely malnourished young children (<5 years) with radiological pneumonia admitted over a 15-month period. Investigations included blood culture, sputa for microscopy and mycobacterial culture. Xpert MTB/RIF assay was introduced during the study. Study children were followed for 12 weeks following their discharge from the hospital. Results 405 eligible children were enrolled, with a median age of 10 months. Bacterial pathogens were isolated from blood culture in 18 (4.4%) children, of which 72% were Gram negatives. Tuberculosis was confirmed microbiologically in 7% (27/396) of children that provided sputum - 10 by culture, 21 by Xpert MTB/RIF assay, and 4 by both tests. The diagnostic yield from induced sputum was 6% compared to 3.5% from gastric aspirate. Sixty (16%) additional children had tuberculosis diagnosed clinically that was not microbiologically confirmed. Most confirmed tuberculosis cases did not have a positive contact history or positive tuberculin test. The sensitivity and specificity of Xpert MTB/RIF assay compared to culture was 67% (95% CI: 24–94) and 92% (95% CI: 87–95) respectively. Overall case-fatality rate was 17% and half of the deaths occurred in home following discharge from the hospital. Conclusion and Significance TB was common in severely malnourished Bangladeshi children with pneumonia. X-pert MTB/RIF assay provided higher case detection rate compared to sputum microscopy and culture. The high mortality among the study children underscores the need for further research aimed at improved case detection and management for better outcomes. PMID:24695758

  20. Microarray multiplex assay for the simultaneous detection and discrimination of hepatitis B, hepatitis C, and human immunodeficiency type-1 viruses in human blood samples

    International Nuclear Information System (INIS)

    Hsia, Chu Chieh; Chizhikov, Vladimir E.; Yang, Amy X.; Selvapandiyan, Angamuthu; Hewlett, Indira; Duncan, Robert; Puri, Raj K.; Nakhasi, Hira L.; Kaplan, Gerardo G.

    2007-01-01

    Hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus type-1 (HIV-1) are transfusion-transmitted human pathogens that have a major impact on blood safety and public health worldwide. We developed a microarray multiplex assay for the simultaneous detection and discrimination of these three viruses. The microarray consists of 16 oligonucleotide probes, immobilized on a silylated glass slide. Amplicons from multiplex PCR were labeled with Cy-5 and hybridized to the microarray. The assay detected 1 International Unit (IU), 10 IU, 20 IU of HBV, HCV, and HIV-1, respectively, in a single multiplex reaction. The assay also detected and discriminated the presence of two or three of these viruses in a single sample. Our data represent a proof-of-concept for the possible use of highly sensitive multiplex microarray assay to screen and confirm the presence of these viruses in blood donors and patients

  1. Assessing sediment contamination using six toxicity assays

    Directory of Open Access Journals (Sweden)

    Allen G. BURTON Jr.

    2001-08-01

    Full Text Available An evaluation of sediment toxicity at Lake Orta, Italy was conducted to compare a toxicity test battery of 6 assays and to evaluate the extent of sediment contamination at various sediment depths. Lake Orta received excessive loadings of copper and ammonia during the 1900’s until a large remediation effort was conducted in 1989-90 using lime addition. Since that time, the lake has shown signs of a steady recovery of biological communities. The study results showed acute toxicity still exists in sediments at a depth of 5 cm and greater. Assays that detected the highest levels of toxicity were two whole sediment exposures (7 d using Hyalella azteca and Ceriodaphnia dubia. The MicrotoxR assay using pore water was the third most sensitive assay. The Thamnotox, Rototox, Microtox solid phase, and Seed Germination-Root Elongation (pore and solid phase assays showed occasional to no toxicity. Based on similarity of responses and assay sensitivity, the two most useful assays were the C. dubia (or H. azteca and Microtox pore water. These assays were effective at describing sediment toxicity in a weight-of-evidence approach.

  2. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    Science.gov (United States)

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  3. Determining the analytical specificity of PCR-based assays for the diagnosis of IA: What is Aspergillus?

    Science.gov (United States)

    Morton, C Oliver; White, P Lewis; Barnes, Rosemary A; Klingspor, Lena; Cuenca-Estrella, Manuel; Lagrou, Katrien; Bretagne, Stéphane; Melchers, Willem; Mengoli, Carlo; Caliendo, Angela M; Cogliati, Massimo; Debets-Ossenkopp, Yvette; Gorton, Rebecca; Hagen, Ferry; Halliday, Catriona; Hamal, Petr; Harvey-Wood, Kathleen; Jaton, Katia; Johnson, Gemma; Kidd, Sarah; Lengerova, Martina; Lass-Florl, Cornelia; Linton, Chris; Millon, Laurence; Morrissey, C Orla; Paholcsek, Melinda; Talento, Alida Fe; Ruhnke, Markus; Willinger, Birgit; Donnelly, J Peter; Loeffler, Juergen

    2017-06-01

    A wide array of PCR tests has been developed to aid the diagnosis of invasive aspergillosis (IA), providing technical diversity but limiting standardisation and acceptance. Methodological recommendations for testing blood samples using PCR exist, based on achieving optimal assay sensitivity to help exclude IA. Conversely, when testing more invasive samples (BAL, biopsy, CSF) emphasis is placed on confirming disease, so analytical specificity is paramount. This multicenter study examined the analytical specificity of PCR methods for detecting IA by blind testing a panel of DNA extracted from a various fungal species to explore the range of Aspergillus species that could be detected, but also potential cross reactivity with other fungal species. Positivity rates were calculated and regression analysis was performed to determine any associations between technical specifications and performance. The accuracy of Aspergillus genus specific assays was 71.8%, significantly greater (P Aspergillus species (47.2%). For genus specific assays the most often missed species were A. lentulus (25.0%), A. versicolor (24.1%), A. terreus (16.1%), A. flavus (15.2%), A. niger (13.4%), and A. fumigatus (6.2%). There was a significant positive association between accuracy and using an Aspergillus genus PCR assay targeting the rRNA genes (P = .0011). Conversely, there was a significant association between rRNA PCR targets and false positivity (P = .0032). To conclude current Aspergillus PCR assays are better suited for detecting A. fumigatus, with inferior detection of most other Aspergillus species. The use of an Aspergillus genus specific PCR assay targeting the rRNA genes is preferential. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Clinical utility of the cryptococcal antigen lateral flow assay in a diagnostic mycology laboratory.

    Directory of Open Access Journals (Sweden)

    Brendan J McMullan

    Full Text Available BACKGROUND: Cryptococcus neoformans causes life-threatening meningitis. A recently introduced lateral flow immunoassay (LFA to detect cryptococcal antigen (CRAG is reportedly more rapid and convenient than standard latex agglutination (LA, but has not yet been evaluated in a diagnostic laboratory setting. METHODS: One hundred and six serum, 42 cerebrospinal fluid (CSF, and 20 urine samples from 92 patients with known or suspected cryptococcosis were tested by LA and LFA, and titres were compared. Results were correlated with laboratory-confirmed cryptococcosis. Serial samples were tested in nine treated patients. RESULTS: Twenty-five of 92 patients had confirmed cryptococcosis; all sera (n = 56 from these patients were positive by LFA (sensitivity 100%, 95% confidence interval (CI 93.6-100% compared with 51/56 positive by LA (sensitivity 91.1%, 95% CI 80.7-96.1%. Fifty sera from 67 patients without cryptococcosis tested negative in both assays. While LA yielded more false negative results (5/56 this did not reach statistical significance (p = 0.063. Nine CSF samples from patients with cryptococcal meningitis yielded positive results using both assays while 17/18 urine samples from patients with cryptococcosis were positive by the LFA. The LFA detected CRAG in C. gattii infection (n = 4 patients. Agreement between titres obtained by both methods (n = 38 samples was imperfect; correlation between log-transformed titres (r was 0.84. Turn-around-time was 20 minutes for the LFA and 2 h for LA. The cost per qualitative sample was 18USD and 91 USD, respectively and per quantitative sample was 38USD and 144USD, respectively. CONCLUSIONS: Qualitative agreement between the LFA and LA assays performed on serum and CSF was good but agreement between titres was imperfect. Ease of performance of the LFA and the capacity for testing urine suggest it has a role in the routine laboratory as a rapid diagnostic test or point-of-care test.

  5. Computational prediction and molecular confirmation of Helitron transposons in the maize genome

    Directory of Open Access Journals (Sweden)

    He Limei

    2008-01-01

    Full Text Available Abstract Background Helitrons represent a new class of transposable elements recently uncovered in plants and animals. One remarkable feature of Helitrons is their ability to capture gene sequences, which makes them of considerable potential evolutionary importance. However, because Helitrons lack the typical structural features of other DNA transposable elements, identifying them is a challenge. Currently, most researchers identify Helitrons manually by comparing sequences. With the maize whole genome sequencing project underway, an automated computational Helitron searching tool is needed. The characterization of Helitron activities in maize needs to be addressed in order to better understand the impact of Helitrons on the organization of the genome. Results We developed and implemented a heuristic searching algorithm in PERL for identifying Helitrons. Our HelitronFinder program will (i take FASTA-formatted DNA sequences as input and identify the hairpin looping patterns, and (ii exploit the consensus 5' and 3' end sequences of known Helitrons to identify putative ends. We randomly selected five predicted Helitrons from the program's high quality output for molecular verification. Four out of the five predicted Helitrons were confirmed by PCR assays and DNA sequencing in different maize inbred lines. The HelitronFinder program identified two head-to-head dissimilar Helitrons in a maize BAC sequence. Conclusion We have identified 140 new Helitron candidates in maize with our computational tool HelitronFinder by searching maize DNA sequences currently available in GenBank. Four out of five candidates were confirmed to be real by empirical methods, thus validating the predictions of HelitronFinder. Additional points to emerge from our study are that Helitrons do not always insert at an AT dinucleotide in the host sequences, that they can insert immediately adjacent to an existing Helitron, and that their movement may cause changes in the flanking

  6. Highly sensitive electrochemical detection of DNA hybridisation by coupling the chemical reduction of a redox label to the electrode reaction of a solution phase mediator.

    Science.gov (United States)

    Ngoensawat, Umphan; Rijiravanich, Patsamon; Somasundrum, Mithran; Surareungchai, Werasak

    2014-11-21

    We have described a highly sensitive method for detecting DNA hybridisation using a redox-labeled stem loop probe. The redox labels were poly(styrene-co-acrylic) (PSA) spheres of 454 nm diameter, modified by methylene blue (MB) deposited alternatively with poly(sodium 4-styrene sulphonate) (PSS) in a layer-by-layer process. Each PSA sphere carried approx. 3.7 × 10(5) molecules of MB, as determined optically. DIG-tagged stem loop probes were immobilised on screen printed electrodes bearing anti-DIG antibodies. Binding with the target enabled straightening of the stem loop, which made attachment to the MB-coated PSA spheres possible. For measuring the current from the direct reduction of MB by differential pulse voltammetry, a 30 mer DNA target common to 70 strains of Escherichia coli was calibrated across the range 1.0 fM to 100 pM (gradient = 3.2 × 10(-8) A (log fM)(-1), r(2) = 0.95, n = 60), with an LOD of ∼58 fM. By using Fe(CN)6(3-/4-) as a solution phase mediator for the MB reduction, we were able to lower the LOD to ∼39 aM (gradient = 5.95 × 10(-8) A (log aM)(-1), r(2) = 0.96, n = 30), which corresponds to the detection of 0.76 ag (∼50 molecules) in the 2 μL analyte sample. We hypothesise that the lowering of the LOD was due to the fact that not all the MB labels were able to contact the electrode surface.

  7. A simple, one-tube assay for the simultaneous detection and diagnosis of ten Australian poultry Eimeria.

    Science.gov (United States)

    Godwin, Rosamond M; Morgan, Jess A T

    2014-02-01

    Coccidiosis is a costly worldwide enteric disease of chickens caused by parasites of the genus Eimeria. At present, there are seven described species that occur globally and a further three undescribed, operational taxonomic units (OTUs X, Y, and Z) that are known to infect chickens from Australia. Species of Eimeria have both overlapping morphology and pathology and frequently occur as mixed-species infections. This makes definitive diagnosis with currently available tests difficult and, to date, there is no test for the detection of the three OTUs. This paper describes the development of a PCR-based assay that is capable of detecting all ten species of Eimeria, including OTUs X, Y, and Z in field samples. The assay is based on a single set of generic primers that amplifies a single diagnostic fragment from the mitochondrial genome of each species. This one-tube assay is simple, low-cost, and has the capacity to be high throughput. It will therefore be of great benefit to the poultry industry for Eimeria detection and control, and the confirmation of identity and purity of vaccine strains. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. ABC Assay: Method Development and Application to Quantify the Role of Three DWV Master Variants in Overwinter Colony Losses of European Honey Bees

    Directory of Open Access Journals (Sweden)

    Jessica L. Kevill

    2017-10-01

    Full Text Available Deformed wing virus (DWV is one of the most prevalent honey bee viral pathogens in the world. Typical of many RNA viruses, DWV is a quasi-species, which is comprised of a large number of different variants, currently consisting of three master variants: Type A, B, and C. Little is known about the impact of each variant or combinations of variants upon the biology of individual hosts. Therefore, we have developed a new set of master variant-specific DWV primers and a set of standards that allow for the quantification of each of the master variants. Competitive reverse transcriptase polymerase chain reaction (RT-PCR experimental design confirms that each new DWV primer set is specific to the retrospective master variant. The sensitivity of the ABC assay is dependent on whether DNA or RNA is used as the template and whether other master variants are present in the sample. Comparison of the overall proportions of each master variant within a sample of known diversity, as confirmed by next-generation sequence (NGS data, validates the efficiency of the ABC assay. The ABC assay was used on archived material from a Devon overwintering colony loss (OCL 2006–2007 study; further implicating DWV type A and, for the first time, possibly C in the untimely collapse of honey bee colonies. Moreover, in this study DWV type B was not associated with OCL. The use of the ABC assay will allow researchers to quickly and cost effectively pre-screen for the presence of DWV master variants in honey bees.

  9. Consumer satisfaction and confirmation of habits of comprehension

    DEFF Research Database (Denmark)

    Sørensen, Bent; Andersen, Christian; Andersen, Morten Purup

    2014-01-01

    the formation of consumer satisfaction; the perspective is that of the confirmation paradigm within advertisement research. Inductive advertisements support cognitive habit formation through confirmation, and the confirmation paradigm explains exactly consumer satisfaction with reference to confirmation. Hence......The purpose of this article is twofold: First, within a Peircean framework it shall be demonstrated how there is a relation between the compositional structure of certain types of print advertisements and their bringing about inductive comprehension, and how the consumer can be understood...... as a bundle of habits. It is the assumption that advertising that supports an inductive effect particularly appeals to the cognitive tendency of habit formation in the consumer. Second, it is asked whether advertisements that predominantly invite inductive processes of comprehension also influence...

  10. Label-Free, LC-MS-Based Assays to Quantitate Small-Molecule Antagonist Binding to the Mammalian BLT1 Receptor.

    Science.gov (United States)

    Chen, Xun; Stout, Steven; Mueller, Uwe; Boykow, George; Visconti, Richard; Siliphaivanh, Phieng; Spencer, Kerrie; Presland, Jeremy; Kavana, Michael; Basso, Andrea D; McLaren, David G; Myers, Robert W

    2017-08-01

    We have developed and validated label-free, liquid chromatography-mass spectrometry (LC-MS)-based equilibrium direct and competition binding assays to quantitate small-molecule antagonist binding to recombinant human and mouse BLT1 receptors expressed in HEK 293 cell membranes. Procedurally, these binding assays involve (1) equilibration of the BLT1 receptor and probe ligand, with or without a competitor; (2) vacuum filtration through cationic glass fiber filters to separate receptor-bound from free probe ligand; and (3) LC-MS analysis in selected reaction monitoring mode for bound probe ligand quantitation. Two novel, optimized probe ligands, compounds 1 and 2, were identified by screening 20 unlabeled BLT1 antagonists for direct binding. Saturation direct binding studies confirmed the high affinity, and dissociation studies established the rapid binding kinetics of probe ligands 1 and 2. Competition binding assays were established using both probe ligands, and the affinities of structurally diverse BLT1 antagonists were measured. Both binding assay formats can be executed with high specificity and sensitivity and moderate throughput (96-well plate format) using these approaches. This highly versatile, label-free method for studying ligand binding to membrane-associated receptors should find broad application as an alternative to traditional methods using labeled ligands.

  11. Genetic Testing Confirmed the Early Diagnosis of X-Linked Hypophosphatemic Rickets in a 7-Month-Old Infant

    Directory of Open Access Journals (Sweden)

    Kok Siong Poon BSc

    2015-08-01

    Full Text Available Loss-of-function mutations in the p hosphate regulating gene with h omologies to e ndopeptidases on the X -chromosome ( PHEX have been causally associated with X-linked hypophosphatemic rickets (XLHR. The early diagnosis of XLHR in infants is challenging when it is based solely on clinical features and biochemical findings. We report a 7-month-old boy with a family history of hypophosphatemic rickets., who demonstrated early clinical evidence of rickets, although serial biochemical findings could not definitively confirm rickets. A sequencing assay targeting the PHEX gene was first performed on the mother’s DNA to screen for mutations in the 5′UTR, 22 coding exons, and the exon-intron junctions. Targeted mutation analysis and mRNA studies were subsequently performed on the boys’ DNA to investigate the pathogenicity of the identified mutation. Genetic screening of the PHEX gene revealed a novel mutation, c.1080-2A>C, at the splice acceptor site in intron 9. The detection of an aberrant mRNA transcript with skipped (loss of exon 10 establishes its pathogenicity and confirms the diagnosis of XLHR in this infant. Genetic testing of the PHEX gene resulted in early diagnosis of XLHR, thus enabling initiation of therapy and prevention of progressive rachitic changes in the infant.

  12. A multiwell format assay for heparanase.

    Science.gov (United States)

    Behzad, Farhad; Brenchley, Paul E C

    2003-09-15

    This assay employs a biotinylated heparan sulfate glycosaminoglycan (HSGAG) substrate that is covalently linked to the surface of 96-well immunoassay plates. The ratio of biotin:HSGAG and the coating concentration of substrate bound to the wells have been optimized and allow removal of biotin HSGAG within 60 min of incubation at 37 degrees C in assay buffer with a standard dilution of bacterial heparitinase or platelet heparanase. Loss of biotin signal from the well surface is detected on incubation with peroxidase-streptavidin followed by color development using 3,3',5,5'-tetramethylbenzidine as the peroxidase substrate. The new assay allows specific detection of heparanase activity in multiple samples in a total time of 3 h including a 1-h substrate digestion step and is a significant improvement with regard to sensitivity, specificity, and ease of handling of multiple samples compared to other described assays. Heparanase specifically degrades the biotinylated HSGAG substrate, when used with an optimized assay buffer. A range of enzymes including collagenase, trypsin, plasmin, pepsin, chondroitinases, hyaluronidase, and neuraminidase show no effect on the substrate under optimized assay conditions. The covalent linkage of the substrate to the well prevents leaching of substrate and allows preparation and long-term storage of substrate-coated plates. The assay can be used to detect heparanase levels in clinical samples and cell culture supernatants and is ideal as a screening method for antagonists of enzyme activity.

  13. A quantitative comet infection assay for influenza virus

    Science.gov (United States)

    Lindsay, Stephen M.; Timm, Andrea; Yin, John

    2011-01-01

    Summary The virus comet assay is a cell-based virulence assay used to evaluate an antiviral drug or antibody against a target virus. The comet assay differs from the plaque assay in allowing spontaneous flows in 6-well plates to spread virus. When implemented quantitatively the comet assay has been shown to have an order-of-magnitude greater sensitivity to antivirals than the plaque assay. In this study, a quantitative comet assay for influenza virus is demonstrated, and is shown to have a 13-fold increase in sensitivity to ribavirin. AX4 cells (MDCK cells with increased surface concentration of α2–6 sialic acid, the influenza virus receptor) have reduced the comet size variability relative to MDCK cells, making them a better host cell for use in this assay. Because of enhanced antiviral sensitivity in flow-based assays, less drug is required, which could lead to lower reagent costs, reduced cytotoxicity, and fewer false-negative drug screen results. The comet assay also serves as a readout of flow conditions in the well. Observations from comets formed at varying humidity levels indicate a role for evaporation in the mechanism of spontaneous fluid flow in wells. PMID:22155578

  14. Assay development status report for total cyanide

    International Nuclear Information System (INIS)

    Simpson, B.C.; Jones, T.E.; Pool, K.H.

    1993-02-01

    A validated cyanide assay that is applicable to a variety of tank waste matrices is necessary to resolve certain waste tank safety issues and for purposes of overall waste characterization. The target for this effort is an assay with an applicable range of greater than 1,000 ppM (0.10 wt%) total cyanide and a confidence level greater than 80%. Figure 1 illustrates the operating regime of the proposed cyanide assay method. The Assay Development Status Report for Total Cyanide will summarize the past experience with cyanide analyses on-tank waste matrices and will rate the status of the analytical methods used to assay total cyanide (CN - ion) in the tank waste matrices as acceptable or unacceptable. This paper will also briefly describe the current efforts for improving analytical resolution of the assays and the attempts at speciation

  15. Confirmation of Essure placement using transvaginal ultrasound.

    Science.gov (United States)

    Veersema, Sebastiaan; Vleugels, Michel; Koks, Caroline; Thurkow, Andreas; van der Vaart, Huub; Brölmann, Hans

    2011-01-01

    To evaluate the protocol for confirmation of satisfactory Essure placement using transvaginal ultrasound. Prospective multicenter cohort study (Canadian Task Force classification II-2). Outpatient departments of 4 teaching hospitals in the Netherlands. Eleven hundred forty-five women who underwent hysteroscopic sterilization using the Essure device between March 2005 and December 2007. Transvaginal ultrasound examination 12 weeks after uncomplicated successful bilateral placement or as indicated according to the transvaginal ultrasound protocol after 4 weeks, and hysterosalpingography (HSG) at 12 weeks to confirm correct placement of the device after 3 months. The rate of successful placement was 88.4% initially. In 164 women (15%), successful placement was confirmed at HSG according the protocol. In 9 patients (0.84%), incorrect position of the device was observed at HSG. The cumulative pregnancy rate after 18 months was 3.85 per thousand women. Transvaginal ultrasound should be the first diagnostic test used to confirm the adequacy of hysteroscopic Essure sterilization because it is minimally invasive, averts ionizing radiation, and does not decrease the effectiveness of the Essure procedure. Copyright © 2011 AAGL. Published by Elsevier Inc. All rights reserved.

  16. Prospects for cellular mutational assays in human populations

    International Nuclear Information System (INIS)

    Mendelsohn, M.L.

    1984-01-01

    Practical, sensitive, and effective human cellular assays for detecting somatic and germinal mutations would have great value in environmental mutagenesis and carcinogenesis studies. Such assays would fill the void between human mutagenicity and the data that exist from short-term tests and from mutagenicity in other species. This paper discusses the following possible human cellular assays: (1) HPRT (hypoxanthine phosphoribosyltransferase) somatic cell mutation based on 6-thioguanine resistance; (2) hemoglobin somatic cell mutation assay; (3) glycophorin somatic cell mutation assay; and (4) LDH-X sperm cell mutation assay. 18 references

  17. Prospects for cellular mutational assays in human populations

    Energy Technology Data Exchange (ETDEWEB)

    Mendelsohn, M.L.

    1984-06-29

    Practical, sensitive, and effective human cellular assays for detecting somatic and germinal mutations would have great value in environmental mutagenesis and carcinogenesis studies. Such assays would fill the void between human mutagenicity and the data that exist from short-term tests and from mutagenicity in other species. This paper discusses the following possible human cellular assays: (1) HPRT (hypoxanthine phosphoribosyltransferase) somatic cell mutation based on 6-thioguanine resistance; (2) hemoglobin somatic cell mutation assay; (3) glycophorin somatic cell mutation assay; and (4) LDH-X sperm cell mutation assay. 18 references.

  18. A radiochemical assay for biotin in biological materials

    International Nuclear Information System (INIS)

    Hood, R.L.

    1975-01-01

    A radiochemical assay for biotin is described. The assay was sensitive to one nanogram and simple enough for routine biotin analyses. The assay yielded results which were comparable to those obtained from a microbiological assay using Lactobacillus plantarum. (author)

  19. Novel Phenotypic Outcomes Identified for a Public Collection of Approved Drugs from a Publicly Accessible Panel of Assays.

    Directory of Open Access Journals (Sweden)

    Jonathan A Lee

    Full Text Available Phenotypic assays have a proven track record for generating leads that become first-in-class therapies. Whole cell assays that inform on a phenotype or mechanism also possess great potential in drug repositioning studies by illuminating new activities for the existing pharmacopeia. The National Center for Advancing Translational Sciences (NCATS pharmaceutical collection (NPC is the largest reported collection of approved small molecule therapeutics that is available for screening in a high-throughput setting. Via a wide-ranging collaborative effort, this library was analyzed in the Open Innovation Drug Discovery (OIDD phenotypic assay modules publicly offered by Lilly. The results of these tests are publically available online at www.ncats.nih.gov/expertise/preclinical/pd2 and via the PubChem Database (https://pubchem.ncbi.nlm.nih.gov/ (AID 1117321. Phenotypic outcomes for numerous drugs were confirmed, including sulfonylureas as insulin secretagogues and the anti-angiogenesis actions of multikinase inhibitors sorafenib, axitinib and pazopanib. Several novel outcomes were also noted including the Wnt potentiating activities of rotenone and the antifolate class of drugs, and the anti-angiogenic activity of cetaben.

  20. Linearization of the Bradford Protein Assay

    OpenAIRE

    Ernst, Orna; Zor, Tsaffrir

    2010-01-01

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, t...

  1. New automated pellet/powder assay system

    International Nuclear Information System (INIS)

    Olsen, R.N.

    1975-01-01

    This paper discusses an automated, high precision, pellet/ powder assay system. The system is an active assay system using a small isotopic neutron source and a coincidence detection system. The handling of the pellet powder samples has been automated and a programmable calculator has been integrated into the system to provide control and data analysis. The versatile system can assay uranium or plutonium in either active or passive modes

  2. Passive nondestructive assay of nuclear materials

    International Nuclear Information System (INIS)

    Reilly, D.; Ensslin, N.; Smith, H. Jr.; Kreiner, S.

    1991-03-01

    The term nondestructive assay (NDA) is applied to a series of measurement techniques for nuclear fuel materials. The techniques measure radiation induced or emitted spontaneously from the nuclear material; the measurements are nondestructive in that they do not alter the physical or chemical state of the nuclear material. NDA techniques are characterized as passive or active depending on whether they measure radiation from the spontaneous decay of the nuclear material or radiation induced by an external source. This book emphasizes passive NDA techniques, although certain active techniques like gamma-ray absorption densitometry and x-ray fluorescence are discussed here because of their intimate relation to passive assay techniques. The principal NDA techniques are classified as gamma-ray assay, neutron assay, and calorimetry. Gamma-ray assay techniques are treated in Chapters 1--10. Neutron assay techniques are the subject of Chapters 11--17. Chapters 11--13 cover the origin of neutrons, neutron interactions, and neutron detectors. Chapters 14--17 cover the theory and applications of total and coincidence neutron counting. Chapter 18 deals with the assay of irradiated nuclear fuel, which uses both gamma-ray and neutron assay techniques. Chapter 19 covers perimeter monitoring, which uses gamma-ray and neutron detectors of high sensitivity to check that no unauthorized nuclear material crosses a facility boundary. The subject of Chapter 20 is attribute and semiquantitative measurements. The goal of these measurements is a rapid verification of the contents of nuclear material containers to assist physical inventory verifications. Waste and holdup measurements are also treated in this chapter. Chapters 21 and 22 cover calorimetry theory and application, and Chapter 23 is a brief application guide to illustrate which techniques can be used to solve certain measurement problems

  3. Opinion dynamics with confirmation bias.

    Directory of Open Access Journals (Sweden)

    Armen E Allahverdyan

    Full Text Available Confirmation bias is the tendency to acquire or evaluate new information in a way that is consistent with one's preexisting beliefs. It is omnipresent in psychology, economics, and even scientific practices. Prior theoretical research of this phenomenon has mainly focused on its economic implications possibly missing its potential connections with broader notions of cognitive science.We formulate a (non-Bayesian model for revising subjective probabilistic opinion of a confirmationally-biased agent in the light of a persuasive opinion. The revision rule ensures that the agent does not react to persuasion that is either far from his current opinion or coincides with it. We demonstrate that the model accounts for the basic phenomenology of the social judgment theory, and allows to study various phenomena such as cognitive dissonance and boomerang effect. The model also displays the order of presentation effect-when consecutively exposed to two opinions, the preference is given to the last opinion (recency or the first opinion (primacy -and relates recency to confirmation bias. Finally, we study the model in the case of repeated persuasion and analyze its convergence properties.The standard Bayesian approach to probabilistic opinion revision is inadequate for describing the observed phenomenology of persuasion process. The simple non-Bayesian model proposed here does agree with this phenomenology and is capable of reproducing a spectrum of effects observed in psychology: primacy-recency phenomenon, boomerang effect and cognitive dissonance. We point out several limitations of the model that should motivate its future development.

  4. Exploring physical and chemical factors influencing the properties of recombinant prion protein and the real-time quaking-induced conversion (RT-QuIC) assay.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; Avery, Kristen M; Coulthart, Michael; Carpenter, Michael; Knox, J David

    2014-01-01

    Real-time quaking-induced conversion (RT-QuIC), a highly specific and sensitive assay able to detect low levels of the disease-inducing isoform of the prion protein (PrP(d)) in brain tissue biopsies and cerebral spinal fluid, has great potential to become a method for diagnosing prion disease ante mortem. In order to standardize the assay method for routine analysis, an understanding of how physical and chemical factors affect the stability of the recombinant prion protein (rPrP) substrate and the RT-QuIC assay's sensitivity, specificity, and reproducibility is required. In this study, using sporadic Creutzfeldt-Jakob Disease brain homogenate to seed the reactions and an in vitro-expressed recombinant prion protein, hamster rPrP, as the substrate, the following factors affecting the RT-QuIC assay were examined: salt and substrate concentrations, substrate storage, and pH. Results demonstrated that both the generation of the quality and quantities of rPrP substrate critical to the reaction, as well as the RT-QuIC reaction itself required strict adherence to specific physical and chemical conditions. Once optimized, the RT-QuIC assay was confirmed to be a very specific and sensitive assay method for sCJD detection. Findings in this study indicate that further optimization and standardization of RT-QuIC assay is required before it can be adopted as a routine diagnostic test.

  5. Evaluation and validation of a real-time PCR assay for detection and quantitation of human adenovirus 14 from clinical samples.

    Directory of Open Access Journals (Sweden)

    David Metzgar

    Full Text Available In 2007, the Centers for Disease Control and Prevention (CDC reported that Human adenovirus type 14 (HAdV-14 infected 106 military personnel and was responsible for the death of one U.S. soldier at Lackland Air Force Base in Texas. Identification of the responsible adenovirus, which had not previously been seen in North America and for which rapid diagnostic tools were unavailable, required retrospective analysis at reference laboratories. Initial quarantine measures were also reliant on relatively slow traditional PCR analysis at other locations. To address this problem, we developed a real-time PCR assay that detects a 225 base pair sequence in the HAdV-14a hexon gene. Fifty-one oropharyngeal swab specimens from the Naval Health Research Center, San Diego, CA and Advanced Diagnostic Laboratory, Lackland AFB, TX were used to validate the new assay. The described assay detected eight of eight and 19 of 19 confirmed HAdV-14a clinical isolates in two separate cohorts from respiratory disease outbreaks. The real-time PCR assay had a wide dynamic range, detecting from 10(2 to 10(7 copies of genomic DNA per reaction. The assay did not cross-react with other adenoviruses, influenza, respiratory syncytial virus, or common respiratory tract bacteria. The described assay is easy to use, sensitive and specific for HAdV-14a in clinical throat swab specimens, and very rapid since turnaround time is less than four hours to obtain an answer.

  6. Rover waste assay system

    International Nuclear Information System (INIS)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J.

    1997-01-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched 235 U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for 137 Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs

  7. Development of a paper-based vertical flow SERS assay for citrulline detection using aptamer-conjugated gold nanoparticles

    Science.gov (United States)

    Locke, Andrea; Deutz, Nicolaas; Coté, Gerard

    2018-02-01

    Research toward development of point-of-care (POC) technologies is emerging as a means for diagnosis and monitoring of patients outside the hospital. These POC devices typically utilize assays capable of detecting low level biomarkers indicative of specific diseases. L-citrulline, an α-amino acid produced in the intestinal mucosa cells, is one such biomarker typically found circulating within the plasma at physiological concentrations of 40 μM. Researchers have found that intestinal enterocyte malfunction causes its level to be significantly lowered, establishing it as a potential diagnostic biomarker for gut function. Our research group has proposed the development of a surface enhanced Raman spectroscopy (SERS) based assay, using vertical flow paper fluidics, for citrulline detection. The assay consists of a fluorescently active, Raman reporter labeled aptamer conjugated on gold nanoparticles. The aptamer changes its confirmation on binding to its target, which in turn changes the distance between the Raman active molecule and the nanoparticle surface. These particles were embedded within a portable chip consisting of cellulose-based paper. After the chips were loaded with different concentrations of free L-citrulline in phosphate buffer, time was given for the assay to interact with the sample. A handheld Raman spectrometer (638 nm; Ocean Optics) was used to measure the SERS intensity. Results showed decrease in intensity with increasing concentration of L-citrulline (0-50μM).

  8. High pressure liquid chromatographic assay of technetium in solutions of sodium pertechnetate produced at the AAEC Research Establishment

    International Nuclear Information System (INIS)

    Farrington, K.J.

    1985-12-01

    High pressure liquid chromatography (HPLC) is used for the assay of nanogram quantities of technetium and to determine technetium in decayed pharmaceutical products, derived from three methods of manufacture. These methods of manufacture give comparably low levels of technetium-99, at the time of collection of the solution. However, when the solutions are used to produce ready-to-inject technetium-99m, high levels of technetium-99 are present at the time of calibration, which is the day after the collection date. Where sensitive reagent kits are to be labelled, freshly collected solutions of technetium-99m should be used. The HPLC assay is a valuable technique for the quality control of technetium-based radiopharmaceuticals, and for investigation of methods of manufacture of technetium-99m. Experimental studies confirmed the findings of previous workers

  9. Comparative evaluation of post-column free radical scavenging and ferric reducing antioxidant power assays for screening of antioxidants in strawberries.

    Science.gov (United States)

    Raudonis, Raimondas; Raudone, Lina; Jakstas, Valdas; Janulis, Valdimaras

    2012-04-13

    ABTS and FRAP post-column techniques evaluate the antioxidant characteristics of HPLC separated compounds with specific reagents. ABTS characterize their ability to scavenge free radicals by electron-donating antioxidants, resulting in the absorbance decrease of the chromophoric radical. FRAP - is based on the reduction of Fe(III)-tripyridyltriazine complex to Fe(II)-tripyridyltriazine at low pH by electron-donating antioxidants, resulting in an absorbance increase. Both post-column assays were evaluated and compared according to the following validation parameters: specificity, precision, limit of detection (LoD), limit of quantitation (LoQ) and linearity. ABTS and FRAP post-column assays were specific, repeatable and sensitive and thus can be used for the evaluation of antioxidant active compounds. Antioxidant active compounds were quantified according to TEAC for each assay and ABTS/FRAP ratio was derived. No previous records of antioxidative activity of leaves and fruits of strawberries (Fragaria viridis, Fragaria moschata) research have been found. The research results confirm the reliability of ABTS and FRAP post-column assays for screening of antioxidants in complex mixtures and the determination of radical scavenging and ferric reducing ability by their TEAC values. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Evaluation of flow cytometric HIT assays in relation to an IgG-Specific immunoassay and clinical outcome.

    Science.gov (United States)

    Kerényi, Adrienne; Beke Debreceni, Ildikó; Oláh, Zsolt; Ilonczai, Péter; Bereczky, Zsuzsanna; Nagy, Béla; Muszbek, László; Kappelmayer, János

    2017-09-01

    Heparin-induced thrombocytopenia (HIT) is a severe side effect of heparin treatment caused by platelet activating IgG antibodies generated against the platelet factor 4 (PF4)-heparin complex. Thrombocytopenia and thrombosis are the leading clinical symptoms of HIT. The clinical pretest probability of HIT was evaluated by the 4T score system. Laboratory testing of HIT was performed by immunological detection of antibodies against PF4-heparin complex (EIA) and two functional assays. Heparin-dependent activation of donor platelets by patient plasma was detected by flow cytometry. Increased binding of Annexin-V to platelets and elevated number of platelet-derived microparticles (PMP) were the indicators of platelet activation. EIA for IgG isotype HIT antibodies was performed in 405 suspected HIT patients. Based on negative EIA results, HIT was excluded in 365 (90%) of cases. In 40 patients with positive EIA test result functional tests were performed. Platelet activating antibodies were detected in 17 cases by Annexin V binding. PMP count analysis provided nearly identical results. The probability of a positive flow cytometric assay result was higher in patients with elevated antibody titer. 71% of patients with positive EIA and functional assay had thrombosis. EIA is an important first line laboratory test in the diagnosis of HIT; however, HIT must be confirmed by a functional test. Annexin V binding and PMP assays using flow cytometry are functional HIT tests convenient in a clinical diagnostic laboratory. The positive results of functional assays may predict the onset of thrombosis. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  11. Radioreceptor assay: theory and applications to pharmacology

    International Nuclear Information System (INIS)

    Perret, G.; Simon, P.

    1984-01-01

    The aim of the first part of this work is to present the theory of the radioreceptor assay and to compare it to the other techniques of radioanalysis (radioimmunoassay, competitive protein binding assays). The technology of the radioreceptor assay is then presented and its components (preparation of the receptors, radioligand, incubation medium) are described. The analytical characteristics of the radioreceptor assay (specificity, sensitivity, reproductibility, accuracy) and the pharmacological significance of the results are discussed. The second part is devoted to the description of the radioreceptor assays of some pharmacological classes (neuroleptics, tricyclic antidepressants, benzodiazepines, β-blockers, anticholinergic drugs) and to their use in therapeutic drug monitoring. In conclusion, by their nature, radioreceptor assays are highly sensitive, reliable, precise, accurate and simple to perform. Their chief disadvantage relates to specificity, since any substance having an appreciable affinity to the receptor site will displace the specifically bound radioligand. Paradoxically in some cases, this lack of specificity may be advantageous in that it allows for the detection of not only the apparent compound but of active metabolites and endogenous receptor agonists as well and in that radioreceptors assays can be devised for a whole pharmacological class and not only for one drug as it is the case for classical physico-chemical techniques. For all these reasons future of radioreceptor assay in pharmacology appears promising [fr

  12. Assay optimization for molecular detection of Zika virus

    NARCIS (Netherlands)

    Corman, Victor M.; Rasche, Andrea; Baronti, Cecile; Aldabbagh, Souhaib; Cadar, Daniel; Reusken, Chantal Bem; Pas, Suzan D.; Goorhuis, Abraham; Schinkel, Janke; Molenkamp, Richard; Kümmerer, Beate M.; Bleicker, Tobias; Brünink, Sebastian; Eschbach-Bludau, Monika; Eis-Hübinger, Anna M.; Koopmans, Marion P.; Schmidt-Chanasit, Jonas; Grobusch, Martin P.; de Lamballerie, Xavier; Drosten, Christian; Drexler, Jan Felix

    2016-01-01

    To examine the diagnostic performance of real-time reverse transcription (RT)-polymerase chain reaction (PCR) assays for Zika virus detection. We compared seven published real-time RT-PCR assays and two new assays that we have developed. To determine the analytical sensitivity of each assay, we

  13. Early postnatal diagnosis of hereditary spherocytosis by combining light microscopy, acidified glycerol lysis test and eosin-5'-maleimide binding assay.

    Science.gov (United States)

    Andres, Oliver; Eber, Stefan; Speer, Christian P

    2015-12-01

    Exact diagnosis of hereditary spherocytosis (HS) is widely considered unreliable around birth. However, early postnatal diagnosis at the beginning of congenital hemolysis may be essential for managing neonatal anemia and hemolytic icterus, identifying those at high risk for severe hyperbilirubinemia, irreversible kernicterus, or sudden need for red cell transfusion. We analyzed 37 blood samples from neonates or infants up to six weeks of life that had been collected in-house or shipped to our laboratory due to suspected red cell membrane disorder. By combining assessment of red cell morphology, acidified glycerol lysis test (AGLT), and eosin-5'-maleimide (EMA) binding assay, we were able to clearly exclude HS in 22 and confirm HS in 10 patients, of which one had undergone red cell transfusion prior to blood sampling. Assessment of red cell morphology and normal test results allowed diagnosis of infantile pyknocytosis or Heinz body anemia in three neonates. Re-evaluation of five patients with inconsistent results of AGLT and EMA binding led to confirmation of HS in two cases. Automated analysis of hematologic parameters revealed elevated proportion of hyperdense cells to be a highly significant indicator for HS in neonatal infants. We showed that assessment of red cell morphology in combination with AGLT and EMA binding assay is a reliable basis for confirming or rejecting suspected diagnosis of HS even in neonates. Our data underline the necessity for blood sampling and laboratory exploration in suspected red cell membrane or enzyme defects at the earliest occasion.

  14. Thyroglobulin (Tg) Testing Revisited: Tg Assays, TgAb Assays, and Correlation of Results With Clinical Outcomes.

    Science.gov (United States)

    Netzel, Brian C; Grebe, Stefan K G; Carranza Leon, B Gisella; Castro, M Regina; Clark, Penelope M; Hoofnagle, Andrew N; Spencer, Carole A; Turcu, Adina F; Algeciras-Schimnich, Alicia

    2015-08-01

    Measurement of thyroglobulin (Tg) by mass spectrometry (Tg-MS) is emerging as a tool for accurate Tg quantification in patients with anti-Tg autoantibodies (TgAbs). The objective of the study was to perform analytical and clinical evaluations of two Tg-MS assays in comparison with immunometric Tg assays (Tg-IAs) and Tg RIAs (Tg-RIAs) in a cohort of thyroid cancer patients. A total of 589 samples from 495 patients, 243 TgAb-/252 TgAb+, were tested by Beckman, Roche, Siemens-Immulite, and Thermo-Brahms Tg and TgAb assays, two Tg-RIAs, and two Tg-MS assays. The frequency of TgAb+ was 58%, 41%, 27%, and 39% for Roche, Beckman, Siemens-Immulite, and Thermo-Brahms, respectively. In TgAb- samples, clinical sensitivities and specificities of 100% and 74%-100%, respectively, were observed across all assays. In TgAb+ samples, all Tg-IAs demonstrated assay-dependent Tg underestimation, ranging from 41% to 86%. In TgAb+ samples, the use of a common cutoff (0.5 ng/mL) for the Tg-MS, three Tg-IAs, and the USC-RIA improved the sensitivity for the Tg-MSs and Tg-RIAs when compared with the Tg-IAs. In up to 20% of TgAb+ cases, Tg-IAs failed to detect Tg that was detectable by Tg-MS. In Tg-RIAs false-high biases were observed in TgAb+ samples containing low Tg concentrations. Tg-IAs remain the method of choice for Tg quantitation in TgAb- patients. In TgAb+ patients with undetectable Tg by immunometric assay, the Tg-MS will detect Tg in up to 20% additional cases. The Tg-RIA will detect Tg in approximately 35% cases, but a significant proportion of these will be clinical false-positive results. The undetectable Tg-MS seen in approximately 40% of TgAb+ cases in patients with disease need further evaluation.

  15. Diagnosis of HEV infection by serological and real-time PCR assays: a study on acute non-A-C hepatitis collected from 2004 to 2010 in Italy

    Directory of Open Access Journals (Sweden)

    Candido Angela

    2012-06-01

    Full Text Available Abstract Background The impact of hepatitis E in developed countries, like Italy, still requires a clear definition. In the present study, we evaluated HEV infection in patients with acute non-A-C hepatitis by an approach comparing data from Real-time PCR and serological assays. Methods In a first analysis, sera from 52 patients hospitalized with a diagnosis of acute viral non-A-C hepatitis in Italy were tested by in-house Real-Time PCR assay for identification of Hepatitis E Virus (HEV RNA and by anti-HEV IgM and IgG assays. In a subsequent analysis, selected samples were evaluated by additional IgM tests to confirm diagnosis. Results Among the 52 samples, 21 showed positive results for all three markers (IgM, IgG and HEV RNA. One patient showed HEV RNA as single marker. Uncertain results were found in 8 samples while the remaining 22 were negative for all markers. Further analysis of the 8 undefined samples by additional IgM tests confirmed HEV infection in 1 patient. Overall, acute HEV infections were reliably identified in 23 (44.2% out of 52 patients. Conclusions In the present paper, we performed a study evaluating HEV infection in 52 sporadic non-A-C acute hepatitis cases. All samples were collected from 2004 to 2010 in Italy. By a diagnostic strategy based on genomic and serological assays we identified HEV infections in 23 out of 52 patients (44.2%, a percentage higher than previous estimates. Thus, the actual impact of HEV infections in Italy needs to be further evaluated on a national scale by a diagnostic strategy based on multiple and last generation assays.

  16. An improved assay for the determination of Huntington`s disease allele size

    Energy Technology Data Exchange (ETDEWEB)

    Reeves, C.; Klinger, K.; Miller, G. [Intergrated Genetics, Framingham, MA (United States)

    1994-09-01

    The hallmark of Huntington`s disease (HD) is the expansion of a polymorphic (CAG)n repeat. Several methods have been published describing PCR amplification of this region. Most of these assays require a complex PCR reaction mixture to amplify this GC-rich region. A consistent problem with trinucleotide repeat PCR amplification is the presence of a number of {open_quotes}stutter bands{close_quotes} which may be caused by primer or amplicon slippage during amplification or insufficient polymerase processivity. Most assays for HD arbitrarily select a particular band for diagnostic purposes. Without a clear choice for band selection such an arbitrary selection may result in inconsistent intra- or inter-laboratory findings. We present an improved protocol for the amplification of the HD trinucleotide repeat region. This method simplifies the PCR reaction buffer and results in a set of easily identifiable bands from which to determine allele size. HD alleles were identified by selecting bands of clearly greater signal intensity. Stutter banding was much reduced thus permitting easy identification of the most relevant PCR product. A second set of primers internal to the CCG polymorphism was used in selected samples to confirm allele size. The mechanism of action of N,N,N trimethylglycine in the PCR reaction is not clear. It may be possible that the minimal isostabilizing effect of N,N,N trimethylglycine at 2.5 M is significant enough to affect primer specificity. The use of N,N,N trimethylglycine in the PCR reaction facilitated identification of HD alleles and may be appropriate for use in other assays of this type.

  17. A reverse transcriptase-PCR assay for detecting filarial infective larvae in mosquitoes.

    Directory of Open Access Journals (Sweden)

    Sandra J Laney

    2008-06-01

    Full Text Available Existing molecular assays for filarial parasite DNA in mosquitoes cannot distinguish between infected mosquitoes that contain any stage of the parasite and infective mosquitoes that harbor third stage larvae (L3 capable of establishing new infections in humans. We now report development of a molecular L3-detection assay for Brugia malayi in vectors based on RT-PCR detection of an L3-activated gene transcript.Candidate genes identified by bioinformatics analysis of EST datasets across the B. malayi life cycle were initially screened by PCR using cDNA libraries as templates. Stage-specificity was confirmed using RNA isolated from infected mosquitoes. Mosquitoes were collected daily for 14 days after feeding on microfilaremic cat blood. RT-PCR was performed with primer sets that were specific for individual candidate genes. Many promising candidates with strong expression in the L3 stage were excluded because of low-level transcription in less mature larvae. One transcript (TC8100, which encodes a particular form of collagen was only detected in mosquitoes that contained L3 larvae. This assay detects a single L3 in a pool of 25 mosquitoes.This L3-activated gene transcript, combined with a control transcript (tph-1, accession # U80971 that is constitutively expressed by all vector-stage filarial larvae, can be used to detect filarial infectivity in pools of mosquito vectors. This general approach (detection of stage-specific gene transcripts from eukaryotic pathogens may also be useful for detecting infective stages of other vector-borne parasites.

  18. Assessment and reduction of comet assay variation in relation to DNA damage: studies from the European Comet Assay Validation Group

    DEFF Research Database (Denmark)

    Møller, Peter; Möller, Lennart; Godschalk, Roger W L

    2010-01-01

    The alkaline single cell gel electrophoresis (comet) assay has become a widely used method for the detection of DNA damage and repair in cells and tissues. Still, it has been difficult to compare results from different investigators because of differences in assay conditions and because the data...... are reported in different units. The European Comet Assay Validation Group (ECVAG) was established for the purpose of validation of the comet assay with respect to measures of DNA damage formation and its repair. The results from this inter-laboratory validation trail showed a large variation in measured level...... reliability for the measurement of DNA damage by the comet assay but there is still a need for further validation to reduce both assay and inter-laboratory variation....

  19. A new scintillation proximity assay-based approach for the detection of KRAS mutations

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So-Young; Lim, Jae-Cheong; Cho, Eun-Ha; Jung, Sung-Hee [Korea Atomic Energy Research Institute (KAERI), Daejeon (Korea, Republic of). Radioisotope Research Div.

    2016-04-01

    KRAS is very commonly mutated resulting in a constitutively activated protein, which is independent of epidermal growth factor receptor (EGFR) ligand binding and resistant to anti-EGFR therapy. Although KRAS is frequently studied, there is still no uniform standard for detecting of KRAS mutations. In this report, a new scintillation proximity assay-based approach is described that determines the relative affinities of wild-type and mutated KRAS to the anti-KRAS antibody. We performed in vitro experiments using normal human colonic cells (CCD18Co), KRAS wild type (Caco-2) and KRAS mutant (HCT 116) cell lines to determine the relative affinities of wild type or mutated KRAS toward an anti-KRAS monoclonal antibody. The process consists of two primary steps: immunoprecipitation from cell lysate to enrich the KRAS protein and the scintillation proximity assay of the immunoprecipitant to determine the relative affinity against the antibody. A fixed concentration of cell lysates was purified by the immunoprecipitation method. The expressions of the KRAS protein in all cell lines was quantitatively confirmed by western blot analysis. For the scintillation proximity assay, the KRAS standard protein was radiolabeled with {sup 125}I by a simple mixing process in the iodogen tube immediately at room temperature immediately before use. The obtained CPM (count per minute) values of were used to calculate the KRAS concentration using purified KRAS as the standard. The calculated relative affinities of 7 μg of Caco-2 and HCT 116 immunoprecipitants for the anti-KRAS antibody were 77 and 0%, respectively. The newly developed scintillation proximity assay-based strategy determines the relative affinities of wild-type or mutated KRAS towards the anti-KRAS monoclonal antibody. This determination can help distinguish mutated KRAS from the wild type protein. The new SPA based approach for detecting KRAS mutations is applicable to many other cancer-related mutations.

  20. A new scintillation proximity assay-based approach for the detection of KRAS mutations

    International Nuclear Information System (INIS)

    Lee, So-Young; Lim, Jae-Cheong; Cho, Eun-Ha; Jung, Sung-Hee

    2016-01-01

    KRAS is very commonly mutated resulting in a constitutively activated protein, which is independent of epidermal growth factor receptor (EGFR) ligand binding and resistant to anti-EGFR therapy. Although KRAS is frequently studied, there is still no uniform standard for detecting of KRAS mutations. In this report, a new scintillation proximity assay-based approach is described that determines the relative affinities of wild-type and mutated KRAS to the anti-KRAS antibody. We performed in vitro experiments using normal human colonic cells (CCD18Co), KRAS wild type (Caco-2) and KRAS mutant (HCT 116) cell lines to determine the relative affinities of wild type or mutated KRAS toward an anti-KRAS monoclonal antibody. The process consists of two primary steps: immunoprecipitation from cell lysate to enrich the KRAS protein and the scintillation proximity assay of the immunoprecipitant to determine the relative affinity against the antibody. A fixed concentration of cell lysates was purified by the immunoprecipitation method. The expressions of the KRAS protein in all cell lines was quantitatively confirmed by western blot analysis. For the scintillation proximity assay, the KRAS standard protein was radiolabeled with 125 I by a simple mixing process in the iodogen tube immediately at room temperature immediately before use. The obtained CPM (count per minute) values of were used to calculate the KRAS concentration using purified KRAS as the standard. The calculated relative affinities of 7 μg of Caco-2 and HCT 116 immunoprecipitants for the anti-KRAS antibody were 77 and 0%, respectively. The newly developed scintillation proximity assay-based strategy determines the relative affinities of wild-type or mutated KRAS towards the anti-KRAS monoclonal antibody. This determination can help distinguish mutated KRAS from the wild type protein. The new SPA based approach for detecting KRAS mutations is applicable to many other cancer-related mutations.

  1. A European multicientre study on the comparison of HIV-1 viral loads between VERIS HIV-1 Assay and Roche COBAS® TAQMAN® HIV-1 test, Abbott RealTime HIV-1 Assay, and Siemens VERSANT HIV-1 Assay.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Hofmann, Jörg; Izopet, Jacques; Kühn, Sebastian; Lombardi, Alessandra; Mancon, Alessandro; Marcos, Mª Angeles; Mileto, Davide; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-07-01

    Viral load monitoring is essential for patients under treatment for HIV. Beckman Coulter has developed the VERIS HIV-1 Assay for use on the novel, automated DxN VERIS Molecular Diagnostics System. ¥ OBJECTIVES: Evaluation of the clinical performance of the new quantitative VERIS HIV-1 Assay at multiple EU laboratories. Method comparison with the VERIS HIV-1 Assay was performed with 415 specimens at 5 sites tested with COBAS ® AmpliPrep/COBAS ® TaqMan ® HIV-1 Test, v2.0, 169 specimens at 3 sites tested with RealTime HIV-1 Assay, and 202 specimens from 2 sites tested with VERSANT HIV-1 Assay. Patient monitoring sample results from 4 sites were also compared. Bland-Altman analysis showed the average bias between VERIS HIV-1 Assay and COBAS HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay to be 0.28, 0.39, and 0.61 log 10 cp/mL, respectively. Bias at low end levels below 1000cp/mL showed predicted bias to be <0.3 log 10 cp/mL for VERIS HIV-1 Assay versus COBAS HIV-1 Test and RealTime HIV-1 Assay, and <0.5 log 10 cp/mL versus VERSANT HIV-1 Assay. Analysis on 174 specimens tested with the 0.175mL volume VERIS HIV-1 Assay and COBAS HIV-1 Test showed average bias of 0.39 log 10 cp/mL. Patient monitoring results using VERIS HIV-1 Assay demonstrated similar viral load trends over time to all comparators. The VERIS HIV-1 Assay for use on the DxN VERIS System demonstrated comparable clinical performance to COBAS ® HIV-1 Test, RealTime HIV-1 Assay, and VERSANT HIV-1 Assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Solid phase radioimmunoassays using labelled antibodies: a conceptual framework for designing assays

    International Nuclear Information System (INIS)

    Kalmakoff, J.; Parkinson, A.J.; Crawford, A.M.; Williams, B.R.G.

    1977-01-01

    A simple theoretical model for the antigen-antibody reaction is presented and used to evaluate the optimum conditions for designing solid phase radioimmunoassays (RIA) using labelled antibodies. Both theoretical and experimental data are presented, using a wide variety of antigens and their corresponding antibodies. The types of RIA described include the direct, the indirect, the direct sandwich assays for detecting either antigen or antibody. The experimental results confirm in a semiquantitative manner that the greatest sensitivity of the RIA is achieved when the smallest amount of labelled antibody is used, that whenever possible the antigen/antibody ratio should be greater than unity(>1), and that the formation of the antigen-antibody complex is dependent on the mass action effect

  3. Model confirmation in climate economics

    Science.gov (United States)

    Millner, Antony; McDermott, Thomas K. J.

    2016-01-01

    Benefit–cost integrated assessment models (BC-IAMs) inform climate policy debates by quantifying the trade-offs between alternative greenhouse gas abatement options. They achieve this by coupling simplified models of the climate system to models of the global economy and the costs and benefits of climate policy. Although these models have provided valuable qualitative insights into the sensitivity of policy trade-offs to different ethical and empirical assumptions, they are increasingly being used to inform the selection of policies in the real world. To the extent that BC-IAMs are used as inputs to policy selection, our confidence in their quantitative outputs must depend on the empirical validity of their modeling assumptions. We have a degree of confidence in climate models both because they have been tested on historical data in hindcasting experiments and because the physical principles they are based on have been empirically confirmed in closely related applications. By contrast, the economic components of BC-IAMs often rely on untestable scenarios, or on structural models that are comparatively untested on relevant time scales. Where possible, an approach to model confirmation similar to that used in climate science could help to build confidence in the economic components of BC-IAMs, or focus attention on which components might need refinement for policy applications. We illustrate the potential benefits of model confirmation exercises by performing a long-run hindcasting experiment with one of the leading BC-IAMs. We show that its model of long-run economic growth—one of its most important economic components—had questionable predictive power over the 20th century. PMID:27432964

  4. Identification of Cyclin-dependent Kinase 1 Specific Phosphorylation Sites by an In Vitro Kinase Assay.

    Science.gov (United States)

    Cui, Heying; Loftus, Kyle M; Noell, Crystal R; Solmaz, Sozanne R

    2018-05-03

    Cyclin-dependent kinase 1 (Cdk1) is a master controller for the cell cycle in all eukaryotes and phosphorylates an estimated 8 - 13% of the proteome; however, the number of identified targets for Cdk1, particularly in human cells is still low. The identification of Cdk1-specific phosphorylation sites is important, as they provide mechanistic insights into how Cdk1 controls the cell cycle. Cell cycle regulation is critical for faithful chromosome segregation, and defects in this complicated process lead to chromosomal aberrations and cancer. Here, we describe an in vitro kinase assay that is used to identify Cdk1-specific phosphorylation sites. In this assay, a purified protein is phosphorylated in vitro by commercially available human Cdk1/cyclin B. Successful phosphorylation is confirmed by SDS-PAGE, and phosphorylation sites are subsequently identified by mass spectrometry. We also describe purification protocols that yield highly pure and homogeneous protein preparations suitable for the kinase assay, and a binding assay for the functional verification of the identified phosphorylation sites, which probes the interaction between a classical nuclear localization signal (cNLS) and its nuclear transport receptor karyopherin α. To aid with experimental design, we review approaches for the prediction of Cdk1-specific phosphorylation sites from protein sequences. Together these protocols present a very powerful approach that yields Cdk1-specific phosphorylation sites and enables mechanistic studies into how Cdk1 controls the cell cycle. Since this method relies on purified proteins, it can be applied to any model organism and yields reliable results, especially when combined with cell functional studies.

  5. Immune chromatography: a quantitative radioimmunological assay

    International Nuclear Information System (INIS)

    Davis, J.W.; Demetriades, M.; Bowen, J.M.

    1984-01-01

    Immune chromatography, a radioimmunological binding assay, employs paper chromatography to separate immune complexes from free antigen and antibodies. During chromatography free antigen and antibodies become distributed throughout the paper, while immune complexes remain near the bottoms of the strips. The chromatographic differences can be made quantitative by using either iodinated antigens or antibodies. Under these conditions nanogram quantities of antigen can be detected or antibodies in sera diluted several 1000-fold. The immune chromatography assay can also be performed as an indirect assay, since the paper strips are cut from nitrocellulose paper. In this case the immune components are absorbed by the paper during chromatography. Antigen is then detected with an iodinated second antibody. The indirect immune chromatography assay is particularly useful for identifying different sera that react with the same antigen. Reaction with the first serum before chromatography reduces the amount of antigen available to the second serum following chromatography. In addition to characterizing the immune chromatography procedure, we discuss the possible applications of chromatography assays for the quantitation of other types of molecular binding interactions. (Auth.)

  6. Introducing MINA--The Molecularly Imprinted Nanoparticle Assay.

    Science.gov (United States)

    Shutov, Roman V; Guerreiro, Antonio; Moczko, Ewa; de Vargas-Sansalvador, Isabel Perez; Chianella, Iva; Whitcombe, Michael J; Piletsky, Sergey A

    2014-03-26

    A new ELISA- (enzyme-linked immunosorbent assay)-like assay is demonstrated in which no elements of biological origin are used for molecular recognition or signaling. Composite imprinted nanoparticles that contain a catalytic core and which are synthesized by using a solid-phase approach can simultaneously act as recognition/signaling elements, and be used with minimal modifications to standard assay protocols. This assay provides a new route towards replacement of unstable biomolecules in immunoassays. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Rover waste assay system

    Energy Technology Data Exchange (ETDEWEB)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched {sup 235}U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for {sup 137}Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs.

  8. Field detection capability of immunochemical assays during criminal investigations involving the use of TNT.

    Science.gov (United States)

    Romolo, Francesco Saverio; Ferri, Elida; Mirasoli, Mara; D'Elia, Marcello; Ripani, Luigi; Peluso, Giuseppe; Risoluti, Roberta; Maiolini, Elisabetta; Girotti, Stefano

    2015-01-01

    immunoassays confirmed that they were suitable to detect post-blast residues in soil and target materials and post transfer residues on hands, allowing further confirmation by more selective techniques. ELISA and LFIAs results obtained from the same solution were consistently in good agreement, and were confirmed by gas chromatography coupled to mass spectrometry (GC-MS). The reported immunoassays data demonstrates the suitability of LFIAs as on-site rapid and effective assays to detect TNT traces. The CL-ELISA proved useful in obtaining very sensitive detection in forensic investigations and testing, while CL-LFIA had performances in between LFIA and CL-ELISA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Assay system

    International Nuclear Information System (INIS)

    Patzke, J.B.; Rosenberg, B.J.

    1984-01-01

    The accuracy of assays for monitoring concentrations of basic drugs in biological fluids containing a 1 -acid glycoproteins, such as blood (serum or plasma), is improved by the addition of certain organic phosphate compounds to minimize the ''protein effect.'' Kits containing the elements of the invention are also disclosed

  10. A simple viability analysis for unicellular cyanobacteria using a new autofluorescence assay, automated microscopy, and ImageJ

    Directory of Open Access Journals (Sweden)

    Schulze Katja

    2011-11-01

    Full Text Available Abstract Background Currently established methods to identify viable and non-viable cells of cyanobacteria are either time-consuming (eg. plating or preparation-intensive (eg. fluorescent staining. In this paper we present a new and fast viability assay for unicellular cyanobacteria, which uses red chlorophyll fluorescence and an unspecific green autofluorescence for the differentiation of viable and non-viable cells without the need of sample preparation. Results The viability assay for unicellular cyanobacteria using red and green autofluorescence was established and validated for the model organism Synechocystis sp. PCC 6803. Both autofluorescence signals could be observed simultaneously allowing a direct classification of viable and non-viable cells. The results were confirmed by plating/colony count, absorption spectra and chlorophyll measurements. The use of an automated fluorescence microscope and a novel ImageJ based image analysis plugin allow a semi-automated analysis. Conclusions The new method simplifies the process of viability analysis and allows a quick and accurate analysis. Furthermore results indicate that a combination of the new assay with absorption spectra or chlorophyll concentration measurements allows the estimation of the vitality of cells.

  11. Molecular confirmation of ovine herpesvirus 2-induced malignant catarrhal fever lesions in cattle from Rio Grande do Norte, Brazil

    Directory of Open Access Journals (Sweden)

    Selwyn A. Headley

    2012-12-01

    Full Text Available Molecular findings that confirmed the participation of ovine herpesvirus 2 (OVH-2 in the lesions that were consistent with those observed in malignant catarrhal fever of cattle are described. Three mixed-breed cattle from Rio Grande do Norte state demonstrated clinical manifestations that included mucopurulent nasal discharge, corneal opacity and motor incoordination. Routine necropsy examination demonstrated ulcerations and hemorrhage of the oral cavity, corneal opacity, and lymph node enlargement. Significant histopathological findings included widespread necrotizing vasculitis, non-suppurative meningoencephalitis, lymphocytic interstitial nephritis and hepatitis, and thrombosis. PCR assay performed on DNA extracted from kidney and mesenteric lymph node of one animal amplified a product of 423 base pairs corresponding to a target sequence within the ovine herpesvirus 2 (OVH-2 tegument protein gene. Direct sequencing of the PCR products, from extracted DNA of the kidney and mesenteric lymph node of one cow, amplified the partial nucleotide sequences (423 base pairs of OVH-2 tegument protein gene. Blast analysis confirmed that these sequences have 98-100% identity with similar OVH-2 sequences deposited in GenBank. Phylogenetic analyses, based on the deduced amino acid sequences, demonstrated that the strain of OVH-2 circulating in ruminants from the Brazilian states of Rio Grande do Norte and Minas Gerais are similar to that identified in other geographical locations. These findings confirmed the active participation of OVH-2 in the classical manifestations of sheep associated malignant catarrhal fever.

  12. Medical Devices; Immunology and Microbiology Devices; Classification of the Assayed Quality Control Material for Clinical Microbiology Assays. Final order.

    Science.gov (United States)

    2017-07-27

    The Food and Drug Administration (FDA, Agency, or we) is classifying the assayed quality control material for clinical microbiology assays into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the assayed quality control material for clinical microbiology assays' classification. The Agency is classifying the device into class II (special controls) to provide a reasonable assurance of safety and effectiveness of the device.

  13. [Comparison of the performance of the ECLusys anti-HCV reagent with the Lumipulse f and HISCL 2000-i HCVAb assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-09-01

    We compared the ECLusys Anti-HCV (ECL) reagent to the Lumipulse f (LPf) and HISCL (HIS) HCV assays. In a correlation test using 210 routine clinical specimens measured using the Lumipulse method (96 positive and 114 negative), most of the results were consistent for all specimens. In a dilution sensitivity test using three different routine positive specimens, the ECL assay enabled detection at higher levels of sensitivity than either the LPf or the HIS assay. Moreover, when the distribution of the cut-off index (C.O.I.) values of the routine LPf negative specimens were compared to those on the ECL and HIS assays, it was found that on the ECL assay, most of the specimens had cut-off index values < 0.1, indicating a more clear-cut distribution. In a specificity test using high RF positive specimens(n = 33), pregnancy specimens (n = 35), cytomegalovirus (CMV) antibody positive specimens (n = 36), and high M protein positive specimens (n = 21), the ECL assay yielded positive results for a CMV antibody positive specimen and three high M protein positive specimens. Further testing using samples from the same patients collected on different days than these four samples resulted in a second positive result for the CMV positive specimen, and single antigen measurement yielded a Core/NS3 positive result, as well, suggesting past infection. However, since negative results were obtained for the three M protein positive specimens, the possibility of this being a ECLusys non-specific reaction could not be ruled out. The above results confirmed that the ECL assay provides superior fundamental performance, and possesses test performance nearly identical to that of the existing measurement methods that are widely used at a large number of facilities, and would therefore be a suitable assay for use in routine HCV antibody screening.

  14. Capillary Electrophoresis Analysis of Conventional Splicing Assays

    DEFF Research Database (Denmark)

    de Garibay, Gorka Ruiz; Acedo, Alberto; García-Casado, Zaida

    2014-01-01

    of these assays is often challenging. Here, we explore this issue by conducting splicing assays in 31 BRCA2 genetic variants. All variants were assessed by RT-PCR followed by capillary electrophoresis and direct sequencing. If assays did not produce clear-cut outputs (Class-2 or Class-5 according to analytical...

  15. Controlling variation in the comet assay

    Directory of Open Access Journals (Sweden)

    Andrew Richard Collins

    2014-10-01

    Full Text Available Variability of the comet assay is a serious issue, whether it occurs from experiment to experiment in the same laboratory, or between different laboratories analysing identical samples. Do we have to live with high variability, just because the comet assay is a biological assay rather than analytical chemistry? Numerous attempts have been made to limit variability by standardising the assay protocol, and the critical steps in the assay have been identified; agarose concentration, duration of alkaline incubation, and electrophoresis conditions (time, temperature and voltage gradient are particularly important. Even when these are controlled, variation seems to be inevitable. It is helpful to include in experiments reference standards, i.e. cells with a known amount of specific damage to the DNA. They can be aliquots frozen from a single large batch of cells, either untreated (negative controls or treated with, for example, H2O2 or X-rays to induce strand breaks (positive control for the basic assay, or photosensitiser plus light to oxidise guanine (positive control for Fpg- or OGG1-sensitive sites. Reference standards are especially valuable when performing a series of experiments over a long period - for example, analysing samples of white blood cells from a large human biomonitoring trial - to check that the assay is performing consistently, and to identify anomalous results necessitating a repeat experiment. The reference values of tail intensity can also be used to iron out small variations occurring from day to day. We present examples of the use of reference standards in human trials, both within one laboratory and between different laboratories, and describe procedures that can be used to control variation.

  16. A feasibility study of adenosine triphosphate-based chemotherapy response assay (ATP-CRA) as a chemosensitivity test for lung cancer.

    Science.gov (United States)

    Kang, Shin Myung; Park, Moo Suk; Chang, Joon; Kim, Se Kyu; Kim, Haeryoung; Shin, Dong-Hwan; Chung, Kyung Young; Kim, Dae Joon; Sohn, Joo Hyuk; Choi, Sung Ho; Kim, Jeongmi; Yoon, Eun Jin; Kim, Joo-Hang

    2005-08-01

    A chemosensitivity test can reflect the differences in responses of individual cancer patients to chemotherapeutic agents. The adenosine triphosphate-based chemotherapy response assay (ATP-CRA) is an accurate method, which does not require a large amount of tissue specimen. So far, no studies have evaluated the utility of the ATP-CRA in Korea. Therefore, we investigated the clinical usefulness of the ATP-CRA in 53 patients with lung cancer. Tumor tissues were obtained from bronchoscopic biopsies or surgical resections. The validity of ATP-CRA was assessed focusing on the success rate, experimental error level (intraassay mean coefficient of variation [CV]) and reproducibility. The overall success rate of ATP-CRA was 90.6% (48/53). Normal cells were effectively eliminated from the tumor tissues with the use of ficoll gradient centrifugation and immunomagnetic separation, which was confirmed using loss of heterozygosity analysis of the 3p deletion. The mean CV of ATP assays was 10.5+/-4.6%. The reproducibility of ATP assays was 94+/-3.8%. The results of the ATP assays were reported to physicians within 7 days of specimen collection. More than 6 anticancer drugs were tested on the tumor specimens obtained from bronchoscopic biopsies. The ATP-CRA is a stable, accurate and potentially practical chemosensitivity test in patients with lung cancer.

  17. Competitive Enzyme-Linked Immunosorbent Assay Based on a Rhoptry-Associated Protein 1 Epitope Specifically Identifies Babesia bovis-Infected Cattle

    Science.gov (United States)

    Goff, Will L.; McElwain, Terry F.; Suarez, Carlos E.; Johnson, Wendell C.; Brown, Wendy C.; Norimine, Junzo; Knowles, Donald P.

    2003-01-01

    The competitive enzyme-linked immunosorbent assay (cELISA) format has proven to be an accurate, reliable, easily standardized, and high-throughput method for detecting hemoparasite infections. In the present study, a species-specific, broadly conserved, and tandemly repeated B-cell epitope within the C terminus of the rhoptry-associated protein 1 of the hemoparasite Babesia bovis was cloned and expressed as a histidine-tagged thioredoxin fusion peptide and used as antigen in a cELISA. The assay was optimized with defined negative and positive bovine sera, where positive sera inhibited the binding of the epitope-specific monoclonal antibody BABB75A4. The cELISA accurately differentiated animals with B. bovis-specific antibodies from uninfected animals and from animals with antibodies against other tick-borne hemoparasites (98.7% specificity). In addition, B. bovis-specific sera from Australia, Argentina, Bolivia, Puerto Rico, and Morocco inhibited the binding of BABB75A4, confirming conservation of the epitope. The assay first detected experimentally infected animals between 13 and 17 days postinfection, and with sera from naturally infected carrier cattle, was comparable to indirect immunofluorescence (98.3% concordance). The assay appears to have the characteristics necessary for an epidemiologic and disease surveillance tool. PMID:12522037

  18. 233U Assay A Neutron NDA System

    International Nuclear Information System (INIS)

    Hensley, D.C.; Lucero, A.J.; Pierce, L.

    1998-01-01

    The assay of highly enriched 233 U material presents some unique challenges. Techniques which apply to the assay of materials of Pu or enriched 235 U do not convert easily over to the assay of 233 U. A specialized neutron assay device is being fabricated to exploit the singles neutron signal, the weak correlated neutron signal, and an active correlated signal. These pieces of information when combined with γ ray isotopics information should give a good overall determination of 233 U material now stored in bldg. 3019 at the Oak Ridge National Laboratory

  19. MCNP efficiency calculations of INEEL passive active neutron assay system for simulated TRU waste assays

    International Nuclear Information System (INIS)

    Yoon, W.Y.; Meachum, T.R.; Blackwood, L.G.; Harker, Y.D.

    2000-01-01

    The Idaho National Engineering and Environmental Laboratory Stored Waste Examination Pilot Plant (SWEPP) passive active neutron (PAN) radioassay system is used to certify transuranic (TRU) waste drums in terms of quantifying plutonium and other TRU element activities. Depending on the waste form involved, significant systematic and random errors need quantification in addition to the counting statistics. To determine the total uncertainty of the radioassay results, a statistical sampling and verification approach has been developed. In this approach, the total performance of the PAN nondestructive assay system is simulated using the computer models of the assay system, and the resultant output is compared with the known input to assess the total uncertainty. The supporting steps in performing the uncertainty analysis for the passive assay measurements in particular are as follows: (1) Create simulated waste drums and associated conditions; (2) Simulate measurements to determine the basic counting data that would be produced by the PAN assay system under the conditions specified; and (3) Apply the PAN assay system analysis algorithm to the set of counting data produced by simulating measurements to determine the measured plutonium mass. The validity of this simulation approach was verified by comparing simulated output against results from actual measurements using known plutonium sources and surrogate waste drums. The computer simulation of the PAN system performance uses the Monte Carlo N-Particle (MCNP) Code System to produce a neutron transport calculation for a simulated waste drum. Specifically, the passive system uses the neutron coincidence counting technique, utilizing the spontaneous fission of 240 Pu. MCNP application to the SWEPP PAN assay system uncertainty analysis has been very useful for a variety of waste types contained in 208-ell drums measured by a passive radioassay system. The application of MCNP to the active radioassay system is also feasible

  20. The impact of HIV infection and CD4 cell count on the performance of an interferon gamma release assay in patients with pulmonary tuberculosis

    DEFF Research Database (Denmark)

    Aabye, Martine G.; Ravn, Pernille; PrayGod, George

    2009-01-01

    pulmonary tuberculosis (PTB) in a TB- and HIV-endemic population and the effect of HIV-infection and CD4 cell count on test performance. METHODOLOGY/PRINCIPAL FINDINGS: 161 patients with sputum culture confirmed PTB were subjected to HIV- and QFT-IT testing and measurement of CD4 cell count. The QFT......BACKGROUND: The performance of the tuberculosis specific Interferon Gamma Release Assays (IGRAs) has not been sufficiently documented in tuberculosis- and HIV-endemic settings. This study evaluated the sensitivity of the QuantiFERON TB-Gold In-Tube (QFT-IT) in patients with culture confirmed...

  1. Computer-determined assay time based on preset precision

    International Nuclear Information System (INIS)

    Foster, L.A.; Hagan, R.; Martin, E.R.; Wachter, J.R.; Bonner, C.A.; Malcom, J.E.

    1994-01-01

    Most current assay systems for special nuclear materials (SNM) operate on the principle of a fixed assay time which provides acceptable measurement precision without sacrificing the required throughput of the instrument. Waste items to be assayed for SNM content can contain a wide range of nuclear material. Counting all items for the same preset assay time results in a wide range of measurement precision and wastes time at the upper end of the calibration range. A short time sample taken at the beginning of the assay could optimize the analysis time on the basis of the required measurement precision. To illustrate the technique of automatically determining the assay time, measurements were made with a segmented gamma scanner at the Plutonium Facility of Los Alamos National Laboratory with the assay time for each segment determined by counting statistics in that segment. Segments with very little SNM were quickly determined to be below the lower limit of the measurement range and the measurement was stopped. Segments with significant SNM were optimally assays to the preset precision. With this method the total assay time for each item is determined by the desired preset precision. This report describes the precision-based algorithm and presents the results of measurements made to test its validity

  2. Serotype determination of Salmonella by xTAG assay.

    Science.gov (United States)

    Zheng, Zhibei; Zheng, Wei; Wang, Haoqiu; Pan, Jincao; Pu, Xiaoying

    2017-10-01

    Currently, no protocols or commercial kits are available to determine the serotypes of Salmonella by using Luminex MAGPIX®. In this study, an xTAG assay for serotype determination of Salmonella suitable for Luminex MAGPIX® is described and 228 Salmonella isolates were serotype determined by this xTAG assay. The xTAG assay consists of two steps: 1) Multiplex PCR to amplify simultaneously O, H and Vi antigen genes of Salmonella, and 2) Magplex-TAG™ microsphere hybridization to identify accurately the specific PCR products of different antigens. Compared with the serotyping results of traditional serum agglutination test, the sensitivity and specificity of the xTAG assay were 95.1% and 100%, respectively. The agreement rate of these two assays was 95.2%. Compared with Luminex xMAP® Salmonella Serotyping Assay (SSA) kit, the advantages of this xTAG assay are: First, the magnetic beads make it applicable to both the Luminex®100/200™ and MAGPIX® systems. Second, only primers rather than both primers and probes are needed in the xTAG assay, and the process of coupling antigen-specific oligonucleotide probes to beads is circumvented, which make the xTAG assay convenient to be utilized by other laboratories. The xTAG assay may serve as a rapid alternative or complementary method for traditional Salmonella serotyping tests, especially for laboratories that utilize the MAGPIX® systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. The comet assay: ready for 30 more years.

    Science.gov (United States)

    Møller, Peter

    2018-02-24

    During the last 30 years, the comet assay has become widely used for the measurement of DNA damage and repair in cells and tissues. A landmark achievement was reached in 2016 when the Organization for Economic Co-operation and Development adopted a comet assay guideline for in vivo testing of DNA strand breaks in animals. However, the comet assay has much more to offer than being an assay for testing DNA strand breaks in animal organs. The use of repair enzymes increases the range of DNA lesions that can be detected with the assay. It can also be modified to measure DNA repair activity. Still, despite the long-term use of the assay, there is a need for studies that assess the impact of variation in specific steps of the procedure. This is particularly important for the on-going efforts to decrease the variation between experiments and laboratories. The articles in this Special Issue of Mutagenesis cover important technical issues of the comet assay procedure, nanogenotoxicity and ionising radiation sensitivity on plant cells. The included biomonitoring studies have assessed seasonal variation and certain predictors for the basal level of DNA damage in white blood cells. Lastly, the comet assay has been used in studies on genotoxicity of environmental and occupational exposures in human biomonitoring studies and animal models. Overall, the articles in this Special Issue demonstrate the versatility of the comet assay and they hold promise that the assay is ready for the next 30 years.

  4. Lack of genotoxicity of potassium iodate in the alkaline comet assay and in the cytokinesis-block micronucleus test. Comparison to potassium bromate.

    Science.gov (United States)

    Poul, J M; Huet, S; Godard, T; Sanders, P

    2004-02-01

    Iodine could be added to the diet of human population in the form of iodide or iodate but iodate had not been adequately tested for genotoxicity and carcinogenicity. In the present study, genotoxic effects of potassium iodate were evaluated in vitro using the alkaline comet assay and the cytokinesis-block micronucleus assay on CHO cells and compared to halogenate salt analogues potassium bromate and chlorate and also to their respective reduced forms (potassium iodide, bromide and chloride). The results showed that the comet assay failed to detect the presence of DNA damage after a treatment of cells by potassium iodate for concentrations up to 10 mM. This absence of primary DNA damage was confirmed in the cytokinesis-block micronucleus assay. In the same way, results showed that potassium chlorate as well as potassium iodide, bromide and chloride did not induced DNA damage in the alkaline comet assay for doses up to 10 mM. By contrast, potassium bromate exposure led to an increase in both DNA damage and frequency of micronucleated cells. The repair of bromate-induced DNA damage was incomplete 24 h after the end of treatment. These results seem to indicate that potassium bromate would induce DNA damage by several mechanisms besides oxidative stress.

  5. Tityus serrulatus Scorpion Venom: In Vitro Tests and Their Correlation with In Vivo Lethal Dose Assay

    Directory of Open Access Journals (Sweden)

    Daniela Cajado-Carvalho

    2017-11-01

    Full Text Available Scorpion stings are the main cause of human envenomation in Brazil and, for the treatment of victims, the World Health Organization (WHO recommends the use of antivenoms. The first step to achieve effective antivenom is to use a good quality venom pool and to evaluate it, with LD50 determination as the most accepted procedure. It is, however, time-consuming and requires advanced technical training. Further, there are significant ethical concerns regarding the number of animals required for testing. Hence, we investigated the correspondence between LD50 results, in vitro assays, and a strong correlation with proteolytic activity levels was observed, showing, remarkably, that proteases are potential toxicity markers for Tityus serrulatus venom. The comparison of reversed-phase chromatographic profiles also has a potential application in venoms’ quality control, as there were fewer neurotoxins detected in the venom with high LD50 value. These results were confirmed by mass spectrometry analysis. Therefore, these methods could precede the LD50 assay to evaluate the venom excellence by discriminating—and discarding—poor-quality batches, and, consequently, with a positive impact on the number of animals used. Notably, proposed assays are fast and inexpensive, being technically and economically feasible in Tityus serrulatus venom quality control to produce effective antivenoms.

  6. Detection and identification of Toscana and other phleboviruses by RT-nested-PCR assays with degenerated primers.

    Science.gov (United States)

    Sánchez-Seco, María-Paz; Echevarría, José-Manuel; Hernández, Lourdes; Estévez, Domingo; Navarro-Marí, José-María; Tenorio, Antonio

    2003-09-01

    Phleboviruses are a large and widespread group of viruses that are transmitted by arthropods. Toscana virus is one of the principal agents that causes meningitis in humans during the summer in Italy and, possibly, in other Mediterranean countries. Rift Valley Fever virus can cause serious illness in both animals and humans, leading to high morbidity and mortality, and is considered to be a potential agent for epizootics and human epidemics. Since information on this group of viruses is still scant, reliable laboratory tools for diagnosis and epidemiological surveillance must be developed, in order to ascertain their real impact on Public Health. Sequence data obtained from Spanish isolates of Toscana virus and other phleboviruses confirmed that natural genome variability may hamper the diagnosis of these agents by molecular methods, so this must be borne in mind when developing reliable assays. In view of the above, a novel and useful protocol has been developed for the detection and specific identification of every member of the phlebovirus genus present in a sample, including Toscana virus, based on a generic RT-nested-PCR, followed by sequencing of the amplified fragment. A change in this method also allowed specific direct detection and identification of wild isolates of Toscana virus of different geographical origin, using newly designed primers. Testing clinical samples with these assays confirmed the role of Toscana virus as an agent that causes acute aseptic meningitis in the central region of Spain. Copyright 2003 Wiley-Liss, Inc.

  7. Assays for calcitonin receptors

    International Nuclear Information System (INIS)

    Teitelbaum, A.P.; Nissenson, R.A.; Arnaud, C.D.

    1985-01-01

    The assays for calcitonin receptors described focus on their use in the study of the well-established target organs for calcitonin, bone and kidney. The radioligand used in virtually all calcitonin binding studies is 125 I-labelled salmon calcitonin. The lack of methionine residues in this peptide permits the use of chloramine-T for the iodination reaction. Binding assays are described for intact bone, skeletal plasma membranes, renal plasma membranes, and primary kidney cell cultures of rats. Studies on calcitonin metabolism in laboratory animals and regulation of calcitonin receptors are reviewed

  8. An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.

    Science.gov (United States)

    Muldrew, Kenneth L; Lovett, Jennie L

    2013-11-01

    BK polyomavirus (BKPyV) quantification is useful for monitoring renal transplant patient response to therapy. The Abbott m2000 RealTime System employed by some clinical laboratories to perform US Food and Drug Administration-approved assays can also be used to develop in-house assays such as the one presented here. This study aimed to validate an in-house quantitative real-time PCR assay targeting the BKPyV major capsid VP1 gene for assessment of viral load using the Abbott m2000 RealTime System. BKPyV load was measured in 95 urine and plasma samples previously tested for BKPyV by one of three laboratories (46 BKPyV-positive samples consisting of 35 plasma and 11 urine samples; 49 samples negative for BKPyV consisting of 47 plasma and two urine samples). Two additional plasma specimens from the College of American Pathologists proficiency testing survey were also analysed. Precision studies were performed by diluting a high-viral-titre patient sample into BKPyV-negative pooled plasma to create high-positive (6.16 log10 copies ml(-1)) and low-positive (3.16 log10 copies ml(-1)) samples. For precision studies of inter-assay variability, a high-positive (7.0 log10 copies ml(-1)) and a low-positive (3.0 log10 copies ml(-1)) sample were measured in 20 separate runs. The assay's limit of quantification and limit of detection were 2.70 and 2.25 log10 copies ml(-1), respectively. The assay was linear from 2.70 to 9.26 log10 copies ml(-1). Of the 48 known positives, 43 were detected as positive, with three reported by the reference laboratory as values lower than the limit of detection. Two known positives at 3.27 and 3.80 log10 copies ml(-1) tested negative by the m2000 BKPyV assay. Of the 49 known negative samples, 48 were negative by the m2000 BKPyV load assay, with one sample confirmed positive by a reference laboratory. Qualitative analysis prior to discrepancy testing demonstrated a sensitivity of 89.58 % and a specificity of 97.96 %. Precision studies

  9. Experience with confirmation measurement at Los Alamos

    International Nuclear Information System (INIS)

    Marshall, R.S.; Wagner, R.P.; Hsue, F.

    1985-01-01

    Confirmation measurements are used at Los Alamos in support of incoming and outgoing shipment accountibility and for support of both at 235 U and Pu inventories. Statistical data are presented to show the consistency of measurements on items of identical composition and on items measured at two facilitis using similar instruments. A description of confirmation measurement techniques used in support of 235 U and Pu inventories and a discussion on the ability of the measurements to identify items with misstated SNM are given

  10. Experience with confirmation measurement at Los Alamos

    International Nuclear Information System (INIS)

    Marshall, R.S.; Wagner, R.P.

    1985-01-01

    Confirmation measurements are used at Los Alamos in support of incoming and outgoing shipment accountability and for support of both 235 U and Pu inventories. Statistical data are presented to show the consistency of measurements on items of identical composition and on items measured at two facilities using similar instruments. A description of confirmation measurement techniques used in support of 235 U and Pu inventories and a discussion on the ability of the measurements to identify items with misstated SNM are given

  11. Troubleshooting Requests e-mail Confirmation

    CERN Multimedia

    TS Department

    2004-01-01

    In an ongoing effort to improve quality of the repair requests, a new e-mail confirmation automatic system will be implemented starting from the 21st October. All repair requests transmitted to the TCR (72201) or the FM Helpdesk (77777) will be confirmed in an e-mail to the requestor, provided that the latter has a valid e-mail address in the HR database. The e-mail will contain a reference number, a brief description of the problem, the location and a contact where more information can be obtained. A second e-mail will be sent when the processing of the repair request is finished. We hope that this initiative will improve the transparency and quality of our service. Helpdesk Troubleshooting Requests (reminder) We remind you that all the repair requests and other communication concerning the CERN machine buildings have to be transmitted to the TCR via 72201, whereas the ones concerning tertiary buildings are handled directly by the FM helpdesk under the phone number 77777, i.e. problems on systems and equ...

  12. Using constitutive activity to define appropriate high-throughput screening assays for orphan g protein-coupled receptors.

    Science.gov (United States)

    Ngo, Tony; Coleman, James L J; Smith, Nicola J

    2015-01-01

    Orphan G protein-coupled receptors represent an underexploited resource for drug discovery but pose a considerable challenge for assay development because their cognate G protein signaling pathways are often unknown. In this methodological chapter, we describe the use of constitutive activity, that is, the inherent ability of receptors to couple to their cognate G proteins in the absence of ligand, to inform the development of high-throughput screening assays for a particular orphan receptor. We specifically focus on a two-step process, whereby constitutive G protein coupling is first determined using yeast Gpa1/human G protein chimeras linked to growth and β-galactosidase generation. Coupling selectivity is then confirmed in mammalian cells expressing endogenous G proteins and driving accumulation of transcription factor-fused luciferase reporters specific to each of the classes of G protein. Based on these findings, high-throughput screening campaigns can be performed on the already miniaturized mammalian reporter system.

  13. Integrated bioassays in microfluidic devices: botulinum toxin assays.

    Science.gov (United States)

    Mangru, Shakuntala; Bentz, Bryan L; Davis, Timothy J; Desai, Nitin; Stabile, Paul J; Schmidt, James J; Millard, Charles B; Bavari, Sina; Kodukula, Krishna

    2005-12-01

    A microfluidic assay was developed for screening botulinum neurotoxin serotype A (BoNT-A) by using a fluorescent resonance energy transfer (FRET) assay. Molded silicone microdevices with integral valves, pumps, and reagent reservoirs were designed and fabricated. Electrical and pneumatic control hardware were constructed, and software was written to automate the assay protocol and data acquisition. Detection was accomplished by fluorescence microscopy. The system was validated with a peptide inhibitor, running 2 parallel assays, as a feasibility demonstration. The small footprint of each bioreactor cell (0.5 cm2) and scalable fluidic architecture enabled many parallel assays on a single chip. The chip is programmable to run a dilution series in each lane, generating concentration-response data for multiple inhibitors. The assay results showed good agreement with the corresponding experiments done at a macroscale level. Although the system has been developed for BoNT-A screening, a wide variety of assays can be performed on the microfluidic chip with little or no modification.

  14. Comet assay on mice testicular cells

    Directory of Open Access Journals (Sweden)

    Anoop Kumar Sharma

    2015-05-01

    Full Text Available Heritable mutations may result in a variety of adverse outcomes including genetic disease in the offspring. In recent years the focus on germ cell mutagenicity has increased and the “Globally Harmonized System of Classification and Labelling of Chemicals (GHS” has published classification criteria for germ cell mutagens (Speit et al., 2009. The in vivo Comet assay is considered a useful tool for investigating germ cell genotoxicity. In the present study DNA strand breaks in testicular cells of mice were investigated. Different classes of chemicals were tested in order to evaluate the sensitivity of the comet assay in testicular cells. The chemicals included environmentally relevant substances such as Bisphenol A, PFOS and Tetrabrombisphenol A. Statistical power calculations will be presented to aid in the design of future Comet assay studies on testicular cells. Power curves were provided with different fold changes in % tail DNA, different number of cells scored and different number of gels (Hansen et al., 2014. An example is shown in Figure 1. A high throughput version of the Comet assay was used. Samples were scored with a fully automatic comet assay scoring system that provided faster scoring of randomly selected cells.

  15. 233U Assay A Neutron NDA System

    Energy Technology Data Exchange (ETDEWEB)

    Hensley, D.C.; Lucero, A.J.; Pierce, L.

    1998-11-17

    The assay of highly enriched {sup 233}U material presents some unique challenges. Techniques which apply to the assay of materials of Pu or enriched {sup 235}U do not convert easily over to the assay of {sup 233}U. A specialized neutron assay device is being fabricated to exploit the singles neutron signal, the weak correlated neutron signal, and an active correlated signal. These pieces of information when combined with {gamma} ray isotopics information should give a good overall determination of {sup 233}U material now stored in bldg. 3019 at the Oak Ridge National Laboratory.

  16. Comparative antioxidant activity of cultivated and wild Vaccinium species investigated by EPR, human neutrophil burst and COMET assay.

    Science.gov (United States)

    Braga, P C; Antonacci, R; Wang, Y Y; Lattuada, N; Dal Sasso, M; Marabini, L; Fibiani, M; Lo Scalzo, R

    2013-01-01

    The Vaccinium (V.) spp. berries are considered a source of antioxidants, mainly belonging to polyphenols, specifically flavonoids and anthocyanins. Wild genotypes generally contain more antioxidants than cultivated counterparts. So, seven different antioxidants assays on extracts from cultivated and wild Vaccinium berries were performed, to evaluate their difference in terms of bioactivity on oxidative protection and minimum dosage to have a significant action. Four cell-free antioxidant assays (ABTS radical scavenging and electronic paramagnetic resonance using Fremy's salt, superoxide anion and hydroxyl radical), and three assays on human cells (two luminol amplified chemiluminescence, LACL, one on DNA damage, COMET) were used to measure the effects of cultivated blueberry (V. corymbosum) and wild bilberry (V. myrtillus) on the differently induced oxidative stress. Concentrations vs activity patterns were obtained by successive dilutions of extracts in order to identify both EC50 and minimum significant activity (MSA). All the assays (except for the hydroxyl radical scavenging) showed a good relationship mainly with anthocyanin and polyphenol content and the significant greater activity of wild Vaccinium extracts. In fact, LACL data gave an EC50 of 11.8 and an MSA of 5.2 g were calculated as fresh weight dosage in cultivated berries, compared with lower doses in wild berries, EC50 of 5.7 g and MSA of 3.4 g. Wild Vaccinium extracts averaged 3.04 and 2.40 fold more activity than cultivated extracts by EC50 and MSA, respectively. COMET assay confirmed the stronger action on DNA protection in wild samples.

  17. Nanoparticle-assay marker interaction: effects on nanotoxicity assessment

    International Nuclear Information System (INIS)

    Zhao, Xinxin; Xiong, Sijing; Huang, Liwen Charlotte; Ng, Kee Woei; Loo, Say Chye Joachim

    2015-01-01

    Protein-based cytotoxicity assays such as lactate dehydrogenase (LDH) and tumor necrosis factor-alpha (TNF-α) are commonly used in cytotoxic evaluation of nanoparticles (NPs) despite numerous reports on possible interactions with protein markers in these assays that can confound the results obtained. In this study, conventional cytotoxicity assays where assay markers may (LDH and TNF- α) or may not (PicoGreen and WST-8) come into contact with NPs were used to evaluate the cytotoxicity of NPs. The findings revealed selective interactions between negatively charged protein assay markers (LDH and TNF- α) and positively charged ZnO NPs under abiotic conditions. The adsorption and interaction with these protein assay markers were strongly influenced by surface charge, concentration, and specific surface area of the NPs, thereby resulting in less than accurate cytotoxic measurements, as observed from actual cell viability measurements. An improved protocol for LDH assay was, therefore, proposed and validated by eliminating any effects associated with protein–particle interactions. In view of this, additional measures and precautions should be taken when evaluating cytotoxicity of NPs with standard protein-based assays, particularly when they are of opposite charges

  18. Nanoparticle-assay marker interaction: effects on nanotoxicity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xinxin; Xiong, Sijing; Huang, Liwen Charlotte; Ng, Kee Woei, E-mail: kwng@ntu.edu.sg; Loo, Say Chye Joachim, E-mail: joachimloo@ntu.edu.sg [Nanyang Technological University, School of Materials Science and Engineering (Singapore)

    2015-01-15

    Protein-based cytotoxicity assays such as lactate dehydrogenase (LDH) and tumor necrosis factor-alpha (TNF-α) are commonly used in cytotoxic evaluation of nanoparticles (NPs) despite numerous reports on possible interactions with protein markers in these assays that can confound the results obtained. In this study, conventional cytotoxicity assays where assay markers may (LDH and TNF- α) or may not (PicoGreen and WST-8) come into contact with NPs were used to evaluate the cytotoxicity of NPs. The findings revealed selective interactions between negatively charged protein assay markers (LDH and TNF- α) and positively charged ZnO NPs under abiotic conditions. The adsorption and interaction with these protein assay markers were strongly influenced by surface charge, concentration, and specific surface area of the NPs, thereby resulting in less than accurate cytotoxic measurements, as observed from actual cell viability measurements. An improved protocol for LDH assay was, therefore, proposed and validated by eliminating any effects associated with protein–particle interactions. In view of this, additional measures and precautions should be taken when evaluating cytotoxicity of NPs with standard protein-based assays, particularly when they are of opposite charges.

  19. Nanoparticle-assay marker interaction: effects on nanotoxicity assessment

    Science.gov (United States)

    Zhao, Xinxin; Xiong, Sijing; Huang, Liwen Charlotte; Ng, Kee Woei; Loo, Say Chye Joachim

    2015-01-01

    Protein-based cytotoxicity assays such as lactate dehydrogenase (LDH) and tumor necrosis factor-alpha (TNF-α) are commonly used in cytotoxic evaluation of nanoparticles (NPs) despite numerous reports on possible interactions with protein markers in these assays that can confound the results obtained. In this study, conventional cytotoxicity assays where assay markers may (LDH and TNF- α) or may not (PicoGreen and WST-8) come into contact with NPs were used to evaluate the cytotoxicity of NPs. The findings revealed selective interactions between negatively charged protein assay markers (LDH and TNF- α) and positively charged ZnO NPs under abiotic conditions. The adsorption and interaction with these protein assay markers were strongly influenced by surface charge, concentration, and specific surface area of the NPs, thereby resulting in less than accurate cytotoxic measurements, as observed from actual cell viability measurements. An improved protocol for LDH assay was, therefore, proposed and validated by eliminating any effects associated with protein-particle interactions. In view of this, additional measures and precautions should be taken when evaluating cytotoxicity of NPs with standard protein-based assays, particularly when they are of opposite charges.

  20. Qualification of standard membrane-feeding assay with Plasmodium falciparum malaria and potential improvements for future assays.

    Directory of Open Access Journals (Sweden)

    Kazutoyo Miura

    Full Text Available Vaccines that interrupt malaria transmission are of increasing interest and a robust functional assay to measure this activity would promote their development by providing a biologically relevant means of evaluating potential vaccine candidates. Therefore, we aimed to qualify the standard membrane-feeding assay (SMFA. The assay measures the transmission-blocking activity of antibodies by feeding cultured P. falciparum gametocytes to Anopheles mosquitoes in the presence of the test antibodies and measuring subsequent mosquito infection. The International Conference on Harmonisation (ICH Harmonised Tripartite Guideline Q2(R1 details characteristics considered in assay validation. Of these characteristics, we decided to qualify the SMFA for Precision, Linearity, Range and Specificity. The transmission-blocking 4B7 monoclonal antibody was tested over 6 feeding experiments at several concentrations to determine four suitable concentrations that were tested in triplicate in the qualification experiments (3 additional feeds to evaluate Precision, Linearity and Range. For Specificity, 4B7 was tested in the presence of normal mouse IgG. We determined intra- and inter-assay variability of % inhibition of mean oocyst intensity at each concentration of 4B7 (lower concentrations showed higher variability. We also showed that % inhibition was dependent on 4B7 concentration and the activity is specific to 4B7. Since obtaining empirical data is time-consuming, we generated a model using data from all 9 feeds and simulated the effects of different parameters on final readouts to improve the assay procedure and analytical methods for future studies. For example, we estimated the effect of number of mosquitoes dissected on variability of % inhibition, and simulated the relationship between % inhibition in oocyst intensity and % inhibition of prevalence of infected mosquitos at different mean oocysts in the control. SMFA is one of the few biological assays used in

  1. Novel gene fusion of PRCC-MITF defines a new member of MiT family translocation renal cell carcinoma: clinicopathological analysis and detection of the gene fusion by RNA sequencing and FISH.

    Science.gov (United States)

    Xia, Qiu-Yuan; Wang, Xiao-Tong; Ye, Sheng-Bing; Wang, Xuan; Li, Rui; Shi, Shan-Shan; Fang, Ru; Zhang, Ru-Song; Ma, Heng-Hui; Lu, Zhen-Feng; Shen, Qin; Bao, Wei; Zhou, Xiao-Jun; Rao, Qiu

    2018-04-01

    MITF, TFE3, TFEB and TFEC belong to the same microphthalmia-associated transcription factor family (MiT). Two transcription factors in this family have been identified in two unusual types of renal cell carcinoma (RCC): Xp11 translocation RCC harbouring TFE3 gene fusions and t(6;11) RCC harbouring a MALAT1-TFEB gene fusion. The 2016 World Health Organisation classification of renal neoplasia grouped these two neoplasms together under the category of MiT family translocation RCC. RCCs associated with the other two MiT family members, MITF and TFEC, have rarely been reported. Herein, we identify a case of MITF translocation RCC with the novel PRCC-MITF gene fusion by RNA sequencing. Histological examination of the present tumour showed typical features of MiT family translocation RCCs, overlapping with Xp11 translocation RCC and t(6;11) RCC. However, this tumour showed negative results in TFE3 and TFEB immunochemistry and split fluorescence in-situ hybridisation (FISH) assays. The other MiT family members, MITF and TFEC, were tested further immunochemically and also showed negative results. RNA sequencing and reverse transcription-polymerase chain reaction confirmed the presence of a PRCC-MITF gene fusion: a fusion of PRCC exon 5 to MITF exon 4. We then developed FISH assays covering MITF break-apart probes and PRCC-MITF fusion probes to detect the MITF gene rearrangement. This study both proves the recurring existence of MITF translocation RCC and expands the genotype spectrum of MiT family translocation RCCs. © 2017 John Wiley & Sons Ltd.

  2. Metal-amplified Density Assays, (MADAs), including a Density-Linked Immunosorbent Assay (DeLISA).

    Science.gov (United States)

    Subramaniam, Anand Bala; Gonidec, Mathieu; Shapiro, Nathan D; Kresse, Kayleigh M; Whitesides, George M

    2015-02-21

    This paper reports the development of Metal-amplified Density Assays, or MADAs - a method of conducting quantitative or multiplexed assays, including immunoassays, by using Magnetic Levitation (MagLev) to measure metal-amplified changes in the density of beads labeled with biomolecules. The binding of target analytes (i.e. proteins, antibodies, antigens) to complementary ligands immobilized on the surface of the beads, followed by a chemical amplification of the binding in a form that results in a change in the density of the beads (achieved by using gold nanoparticle-labeled biomolecules, and electroless deposition of gold or silver), translates analyte binding events into changes in density measureable using MagLev. A minimal model based on diffusion-limited growth of hemispherical nuclei on a surface reproduces the dynamics of the assay. A MADA - when performed with antigens and antibodies - is called a Density-Linked Immunosorbent Assay, or DeLISA. Two immunoassays provided a proof of principle: a competitive quantification of the concentration of neomycin in whole milk, and a multiplexed detection of antibodies against Hepatitis C virus NS3 protein and syphilis T. pallidum p47 protein in serum. MADAs, including DeLISAs, require, besides the requisite biomolecules and amplification reagents, minimal specialized equipment (two permanent magnets, a ruler or a capillary with calibrated length markings) and no electrical power to obtain a quantitative readout of analyte concentration. With further development, the method may be useful in resource-limited or point-of-care settings.

  3. Chromosome aberration assays in Allium

    Energy Technology Data Exchange (ETDEWEB)

    Grant, W.F.

    1982-01-01

    The common onion (Allium cepa) is an excellent plant for the assay of chromosome aberrations after chemical treatment. Other species of Allium (A. cepa var. proliferum, A. carinatum, A. fistulosum and A. sativum) have also been used but to a much lesser extent. Protocols have been given for using root tips from either bulbs or seeds of Allium cepa to study the cytological end-points, such as chromosome breaks and exchanges, which follow the testing of chemicals in somatic cells. It is considered that both mitotic and meiotic end-points should be used to a greater extent in assaying the cytogenetic effects of a chemical. From a literature survey, 148 chemicals are tabulated that have been assayed in 164 Allium tests for their clastogenic effect. Of the 164 assays which have been carried out, 75 are reported as giving a positive reaction, 49 positive and with a dose response, 1 positive and temperature-related, 9 borderline positive, and 30 negative; 76% of the chemicals gave a definite positive response. It is proposed that the Allium test be included among those tests routinely used for assessing chromosomal damage induced by chemicals.

  4. White blood cell-based detection of asymptomatic scrapie infection by ex vivo assays.

    Directory of Open Access Journals (Sweden)

    Sophie Halliez

    Full Text Available Prion transmission can occur by blood transfusion in human variant Creutzfeldt-Jakob disease and in experimental animal models, including sheep. Screening of blood and its derivatives for the presence of prions became therefore a major public health issue. As infectious titer in blood is reportedly low, highly sensitive and robust methods are required to detect prions in blood and blood derived products. The objectives of this study were to compare different methods--in vitro, ex vivo and in vivo assays--to detect prion infectivity in cells prepared from blood samples obtained from scrapie infected sheep at different time points of the disease. Protein misfolding cyclic amplification (PMCA and bioassays in transgenic mice expressing the ovine prion protein were the most efficient methods to identify infected animals at any time of the disease (asymptomatic to terminally-ill stages. However scrapie cell and cerebellar organotypic slice culture assays designed to replicate ovine prions in culture also allowed detection of prion infectivity in blood cells from asymptomatic sheep. These findings confirm that white blood cells are appropriate targets for preclinical detection and introduce ex vivo tools to detect blood infectivity during the asymptomatic stage of the disease.

  5. Identification of adiponectin receptor agonist utilizing a fluorescence polarization based high throughput assay.

    Directory of Open Access Journals (Sweden)

    Yiyi Sun

    Full Text Available Adiponectin, the adipose-derived hormone, plays an important role in the suppression of metabolic disorders that can result in type 2 diabetes, obesity, and atherosclerosis. It has been shown that up-regulation of adiponectin or adiponectin receptor has a number of therapeutic benefits. Given that it is hard to convert the full size adiponectin protein into a viable drug, adiponectin receptor agonists could be designed or identified using high-throughput screening. Here, we report on the development of a two-step screening process to identify adiponectin agonists. First step, we developed a high throughput screening assay based on fluorescence polarization to identify adiponectin ligands. The fluorescence polarization assay reported here could be adapted to screening against larger small molecular compound libraries. A natural product library containing 10,000 compounds was screened and 9 hits were selected for validation. These compounds have been taken for the second-step in vitro tests to confirm their agonistic activity. The most active adiponectin receptor 1 agonists are matairesinol, arctiin, (--arctigenin and gramine. The most active adiponectin receptor 2 agonists are parthenolide, taxifoliol, deoxyschizandrin, and syringin. These compounds may be useful drug candidates for hypoadiponectin related diseases.

  6. Hemizona Assay and Sperm Penetration Assay in the Prediction of IVF Outcome: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Paraskevi Vogiatzi

    2013-01-01

    Full Text Available The limited predictive value of semen analysis in achieving natural conception or in IVF outcome confirms the need for sperm function tests to determine optimal management. We reviewed HZA and SPA predictive power in IVF outcome, with statistical significance of diagnostic power of the assays. HZA was readily efficient in predicting IVF outcome, while evident inconsistency among the studies analysed framed the SPA’s role in male fertility evaluation. Considerable variation was noted in the diagnostic accuracy values of SPA with wide sensitivity (52–100%, specificity (0–100%, and PPV (18–100% and NPV (0–100% together with fluctuation and notable differentiation in methodology and cutoff values employed by each group. HZA methodology was overall consistent with minor variation in cutoff values and oocyte source, while data analysis reported strong correlation between HZA results with IVF outcome, high sensitivity (75–100%, good specificity (57–100%, and high PPV (79–100% and NPV (68–100%. HZA correlated well with IVF outcome and demonstrated better sensitivity/specificity and positive/negative predictive power. Males with normal or slightly abnormal semen profiles could benefit by this intervention and could be evaluated prior to referral to assisted reproduction. HZA should be used in a sequential fashion with semen analysis and potentially other bioassays in an IVF setting.

  7. Optimization and Evaluation of a PCR Assay for Detecting Toxoplasmic Encephalitis in Patients with AIDS

    Science.gov (United States)

    Joseph, Priya; Calderón, Maritza M.; Gilman, Robert H.; Quispe, Monica L.; Cok, Jaime; Ticona, Eduardo; Chavez, Victor; Jimenez, Juan A.; Chang, Maria C.; Lopez, Martín J.; Evans, Carlton A.

    2002-01-01

    Toxoplasma gondii is a common life-threatening opportunistic infection. We used experimental murine T. gondii infection to optimize the PCR for diagnostic use, define its sensitivity, and characterize the time course and tissue distribution of experimental toxoplasmosis. PCR conditions were adjusted until the assay reliably detected quantities of DNA derived from less than a single parasite. Forty-two mice were inoculated intraperitoneally with T. gondii tachyzoites and sacrificed from 6 to 72 h later. Examination of tissues with PCR and histology revealed progression of infection from blood to lung, heart, liver, and brain, with PCR consistently detecting parasites earlier than microscopy and with no false-positive results. We then evaluated the diagnostic value of this PCR assay in human patients. We studied cerebrospinal fluid and serum samples from 12 patients with AIDS and confirmed toxoplasmic encephalitis (defined as positive mouse inoculation and/or all of the Centers for Disease Control clinical diagnostic criteria), 12 human immunodeficiency virus-infected patients with suspected cerebral toxoplasmosis who had neither CDC diagnostic criteria nor positive mouse inoculation, 26 human immunodeficiency virus-infected patients with other opportunistic infections and no signs of cerebral toxoplasmosis, and 18 immunocompetent patients with neurocysticercosis. Eleven of the 12 patients with confirmed toxoplasmosis had positive PCR results in either blood or cerebrospinal fluid samples (6 of 9 blood samples and 8 of 12 cerebrospinal fluid samples). All samples from control patients were negative. This study demonstrates the high sensitivity, specificity, and clinical utility of PCR in the diagnosis of toxoplasmic encephalitis in a resource-poor setting. PMID:12454142

  8. Automation of cell-based drug absorption assays in 96-well format using permeable support systems.

    Science.gov (United States)

    Larson, Brad; Banks, Peter; Sherman, Hilary; Rothenberg, Mark

    2012-06-01

    Cell-based drug absorption assays, such as Caco-2 and MDCK-MDR1, are an essential component of lead compound ADME/Tox testing. The permeability and transport data they provide can determine whether a compound continues in the drug discovery process. Current methods typically incorporate 24-well microplates and are performed manually. Yet the need to generate absorption data earlier in the drug discovery process, on an increasing number of compounds, is driving the use of higher density plates. A simple, more efficient process that incorporates 96-well permeable supports and proper instrumentation in an automated process provides more reproducible data compared to manual methods. Here we demonstrate the ability to perform drug permeability and transport assays using Caco-2 or MDCKII-MDR1 cells. The assay procedure was automated in a 96-well format, including cell seeding, media and buffer exchanges, compound dispense, and sample removal using simple robotic instrumentation. Cell monolayer integrity was confirmed via transepithelial electrical resistance and Lucifer yellow measurements. Proper cell function was validated by analyzing apical-to-basolateral and basolateral-to-apical movement of rhodamine 123, a known P-glycoprotein substrate. Apparent permeability and efflux data demonstrate how the automated procedure provides a less variable method than manual processing, and delivers a more accurate assessment of a compound's absorption characteristics.

  9. Factor IX assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003679.htm Factor IX assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  10. Factor VIII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003678.htm Factor VIII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  11. Factor II assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003674.htm Factor II assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  12. Factor VII assay

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003676.htm Factor VII assay To use the sharing features on ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  13. Multiplexing a high-throughput liability assay to leverage efficiencies.

    Science.gov (United States)

    Herbst, John; Anthony, Monique; Stewart, Jeremy; Connors, David; Chen, Taosheng; Banks, Martyn; Petrillo, Edward W; Agler, Michele

    2009-06-01

    In order to identify potential cytochrome P-450 3A4 (drug-metabolizing enzyme) inducers at an early stage of the drug discovery process, a cell-based transactivation high-throughput luciferase reporter assay for the human pregnane X receptor (PXR) in HepG2 cells has been implemented and multiplexed with a viability end point for data interpretation, as part of a Lead Profiling portfolio of assays. As a routine part of Lead Profiling operations, assays are periodically evaluated for utility as well as for potential improvements in technology or process. We used a recent evaluation of our PXR-transactivation assay as a model for the application of Lean Thinking-based process analysis to lab-bench assay optimization and automation. This resulted in the development of a 384-well multiplexed homogeneous assay simultaneously detecting PXR transactivation and HepG2 cell cytotoxicity. In order to multiplex fluorescent and luminescent read-outs, modifications to each assay were necessary, which included optimization of multiple assay parameters such as cell density, plate type, and reagent concentrations. Subsequently, a set of compounds including known cytotoxic compounds and PXR inducers were used to validate the multiplexed assay. Results from the multiplexed assay correlate well with those from the singleplexed assay formats measuring PXR transactivation and viability separately. Implementation of the multiplexed assay for routine compound profiling provides improved data quality, sample conservation, cost savings, and resource efficiencies.

  14. Evaluation of Presto(plus) assay and LightMix kit Trichomonas vaginalis assay for detection of Trichomonas vaginalis in dry vaginal swabs.

    Science.gov (United States)

    de Waaij, Dewi J; Ouburg, Sander; Dubbink, Jan Henk; Peters, Remco P H; Morré, Servaas A

    2016-08-01

    This is an evaluation study of the Presto(plus) Assay for T. vaginalis by comparing to the TIB MOLBIOL LightMix Kit Trichomonas vaginalis Assay using 615 dry collected vaginal and rectal swabs. Discordant samples were analyzed by the Qiagen® Microbial DNA qPCR for TV Assay. Both assays showed comparable performances (McNemar p>0.05). Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Nondestructive assay methods for irradiated nuclear fuels

    International Nuclear Information System (INIS)

    Hsue, S.T.; Crane, T.W.; Talbert, W.L. Jr.; Lee, J.C.

    1978-01-01

    This report is a review of the status of nondestructive assay (NDA) methods used to determine burnup and fissile content of irradiated nuclear fuels. The gamma-spectroscopy method measures gamma activities of certain fission products that are proportional to the burnup. Problems associated with this method are migration of the fission products and gamma-ray attenuation through the relatively dense fuel material. The attenuation correction is complicated by generally unknown activity distributions within the assemblies. The neutron methods, which usually involve active interrogation and prompt or delayed signal counting, are designed to assay the fissile content of the spent-fuel elements. Systems to assay highly enriched spent-fuel assemblies have been tested extensively. Feasibility studies have been reported of systems to assay light-water reactor spent-fuel assemblies. The slowing-down spectrometer and neutron resonance absorption methods can distinguish between the uranium and plutonium fissile contents, but they are limited to the assay of individual rods. We have summarized the status of NDA techniques for spent-fuel assay and present some subjects in need of further investigation. Accuracy of the burnup calculations for power reactors is also reviewed

  16. Comparison of two high-throughput assays for quantification of adenovirus type 5 neutralizing antibodies in a population of donors in China.

    Directory of Open Access Journals (Sweden)

    Qiang Liu

    Full Text Available BACKGROUND: The presence of various levels of Adenovirus serotype 5 neutralizing antibodies (Ad5NAb is thought to contribute to the inconsistent clinical results obtained from vaccination and gene therapy studies. Currently, two platforms based on high-throughput technology are available for Ad5NAb quantification, chemiluminescence- and fluorescence-based assays. The aim of this study was to compare the results of two assays in the seroepidemiology of Ad5NAb in a local population of donors. METHODOLOGY/PRINCIPAL FINDINGS: The fluorescence-based neutralizing antibody detection test (FRNT using recombinant Ad5-EGFP virus and the chemiluminescence-based neutralizing antibody test (CLNT using Ad5-Fluc were developed and standardized for detecting the presence of Ad5NAb in serum samples from the population of donors in Beijing and Anhui provinces, China. First, the overall percentage of people positive for Ad5NAb performed by CLNT was higher than that obtained by FRNT (85.4 vs 69.9%, p<0.001. There was an 84.5% concordance between the two assays for the 206 samples tested (144 positive in both assays and 30 negative in both assays. All 32 discordant sera were CLNT-positive/FRNT-negative and were confirmed positive by western blot. Secondly, for all 144 sera positive by both assays, the two assays showed high correlation (r = 0.94, p<0.001 and close agreement (mean difference: 0.395 log(10, 95% CI: -0.054 log(10 to 0.845 log(10. Finally, it was found by both assays that there was no significant difference observed for titer or prevalence by gender (p = 0.503 vs 0.818, for two assays; however, age range (p = 0.049 vs 0.010 and geographic origin (p = 0.007 vs 0.011 were correlated with Ad5NAb prevalence in northern regions of China. CONCLUSION: The CLNT assay was relatively more simple and had higher sensitivity than the FRNT assay for determining Ad5NAb titers. It is strongly suggested that the CLNT assay be used for future

  17. The microculture-kinetic (MiCK) assay: the role of a drug-induced apoptosis assay in drug development and clinical care.

    Science.gov (United States)

    Bosserman, Linda; Prendergast, Franklyn; Herbst, Roy; Fleisher, Martin; Salom, Emery; Strickland, Steven; Raptis, Anastasios; Hallquist, Allan; Perree, Mathieu; Rajurkar, Swapnil; Karimi, Misagh; Rogers, Karl; Davidson, Dirk; Willis, Carl; Penalver, Manuel; Homesley, Howard; Burrell, Matthew; Garrett, Audrey; Rutledge, James; Chernick, Michael; Presant, Cary A

    2012-08-15

    A drug-induced apoptosis assay, termed the microculture-kinetic (MiCK) assay, has been developed. Blinded clinical trials have shown higher response rates and longer survival in groups of patients with acute myelocytic leukemia and epithelial ovarian cancer who have been treated with drugs that show high apoptosis in the MiCK assay. Unblinded clinical trials in multiple tumor types have shown that the assay will be used frequently by clinicians to determine treatment, and when used, results in higher response rates, longer times to relapse, and longer survivals. Model economic analyses suggest possible cost savings in clinical use based on increased generic drug use and single-agent substitution for combination therapies. Two initial studies with drugs in development are promising. The assay may help reduce costs and speed time to drug approval. Correlative studies with molecular biomarkers are planned. This assay may have a role both in personalized clinical therapy and in more efficient drug development. ©2012 AACR.

  18. A serum and platelet-rich plasma serotonin assay using liquid chromatography tandem mass spectrometry for monitoring of neuroendocrine tumor patients.

    Science.gov (United States)

    Korse, Catharina M; Buning-Kager, Johanna C G M; Linders, Theodora C; Heijboer, Annemieke C; van den Broek, Daan; Tesselaar, Margot E T; van Tellingen, Olaf; van Rossum, Huub H

    2017-06-01

    Serotonin is used for the diagnosis and follow-up of neuroendocrine tumors (NET). We describe the analytical and clinical validation of a liquid chromatography tandem mass spectrometry (LC-MS/MS) based serotonin assay for serum and platelet-rich plasma (PRP). An LC-MS/MS based method for serum and PRP serotonin was validated by determination of assay imprecision, carry-over, linearity, interference, recovery, sample stability and a matrix/method comparison of serum and PRP serotonin was made with whole blood serotonin. Furthermore, upper limits of normal were determined and serotonin concentrations of healthy individuals, 14 NET patients without evidence of disease and 51 NET patients with evidence of disease were compared. For serum and PRP fractions, total assay imprecision was serotonin upper limit of normal were 5.5nmol/10 9 platelet and 5.1nmol/10 9 platelet, respectively. NET patients with confirmed evidence of disease had significantly higher serum and PRP serotonin levels when compared to NET patients without evidence of disease and healthy volunteers. LC-MS/MS based serum and PRP serotonin assays were developed with suitable analytical characteristics. Furthermore, serum and PRP serotonin was found to be useful for monitoring NET patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. [Diagnostic and therapeutic approach of intraabdominal candidiasis].

    Science.gov (United States)

    Montero, A; Gilsanz, F; Maseda, E

    2016-09-01

    Invasive fungal disease is associated to a high mortality rate on critical ill patients. In the last decades an important epidemiological shift has been described. Early diagnosis and treatment are related with a better prognosis. The key factors lie in a set of predictive scores that allow to identify patients that will benefit of early treatment, as well as using diagnosis techniques that are culture independent. New diagnosis approximations are being developed with promising results: in situ hybridisation using PNA-FISH probes, MALDI-TOF MS and rapid nucleic acids detection assays. The use of echinocandin is recommended as antifungal therapy on critical ill patients with candida peritonitis.

  20. Response to challenging dose of x-rays as a predictive assay for molecular epidemiology

    International Nuclear Information System (INIS)

    Cebulska-Wasilewska, A.

    2003-01-01

    Human biomonitoring, as a tool to identify or quantify the potential risk from genotoxic exposures, has gained increasing interest especially in the areas of cancer risk assessment and diseases treatment. Chromosome aberrations resulting from direct DNA breakage or from inhibition of DNA repair or synthesis, measured in peripheral blood lymphocytes have been used in occupational health surveillance programs in order to assess risks from exposures. Many results in our human monitoring studies have shown influence of the environmental or occupational exposure on the cytogenetic damage detected in lymphocytes, confirming both, the association with adverse health outcome and the influence of life style related confounding factors. Susceptibility to the environmental agent actions was also evaluated in lymphocytes in the studies of variation between responses to the challenging dose of UV or X-rays followed by the evaluation of the repair capacity of the DNA damage induced by a challenging dose. The induced and residual DNA damage was analyzed with the use of SCGE assay. Susceptibility and repair capacities of healthy donors and cancer patients were compared. Studies have shown a good correlation between DNA damage induced in vivo or in vitro and cytogenetic measures. Results from studies on susceptibilities and repair competence performed in occupationally exposed and unexposed 475 healthy donors and patients with diagnosed cancer are discussed. Significantly lower efficiency of repair process was observed in cancer patients. The possible effects on repair competency of various occupational exposures and influence of the diet and other confounding factors is shown. Although in our preliminary studies comet assay failed to detect DNA damage repair disorders in a teratoma immature infant, though, prospective use of a challenging dose of radiation combined with the comet assay as a predictive assay is suggested and limitation discussed

  1. Radioligand assay in reproductive biology

    International Nuclear Information System (INIS)

    Korenman, S.G.; Sherman, B.M.

    1975-01-01

    Radioligand assays have been developed for the principal reproductive steroids and peptide hormones. Specific binding reagents have included antibodies, plasma binders, and intracellular receptors. In each assay, problems of specificity, sensitivity, and nonspecific inhibitors were encountered. Many features of the endocrine physiology in childhood, during puberty, and in adulthood have been characterized. Hormonal evaluations of endocrine disorders of reproduction are characterized on the basis of their characteristic pathophysiologic alterations. (U.S.)

  2. Clinical validation of an epigenetic assay to predict negative histopathological results in repeat prostate biopsies.

    Science.gov (United States)

    Partin, Alan W; Van Neste, Leander; Klein, Eric A; Marks, Leonard S; Gee, Jason R; Troyer, Dean A; Rieger-Christ, Kimberly; Jones, J Stephen; Magi-Galluzzi, Cristina; Mangold, Leslie A; Trock, Bruce J; Lance, Raymond S; Bigley, Joseph W; Van Criekinge, Wim; Epstein, Jonathan I

    2014-10-01

    The DOCUMENT multicenter trial in the United States validated the performance of an epigenetic test as an independent predictor of prostate cancer risk to guide decision making for repeat biopsy. Confirming an increased negative predictive value could help avoid unnecessary repeat biopsies. We evaluated the archived, cancer negative prostate biopsy core tissue samples of 350 subjects from a total of 5 urological centers in the United States. All subjects underwent repeat biopsy within 24 months with a negative (controls) or positive (cases) histopathological result. Centralized blinded pathology evaluation of the 2 biopsy series was performed in all available subjects from each site. Biopsies were epigenetically profiled for GSTP1, APC and RASSF1 relative to the ACTB reference gene using quantitative methylation specific polymerase chain reaction. Predetermined analytical marker cutoffs were used to determine assay performance. Multivariate logistic regression was used to evaluate all risk factors. The epigenetic assay resulted in a negative predictive value of 88% (95% CI 85-91). In multivariate models correcting for age, prostate specific antigen, digital rectal examination, first biopsy histopathological characteristics and race the test proved to be the most significant independent predictor of patient outcome (OR 2.69, 95% CI 1.60-4.51). The DOCUMENT study validated that the epigenetic assay was a significant, independent predictor of prostate cancer detection in a repeat biopsy collected an average of 13 months after an initial negative result. Due to its 88% negative predictive value adding this epigenetic assay to other known risk factors may help decrease unnecessary repeat prostate biopsies. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. A high-throughput screening assay for eukaryotic elongation factor 2 kinase inhibitors

    Directory of Open Access Journals (Sweden)

    Ting Xiao

    2016-10-01

    Full Text Available Eukaryotic elongation factor 2 kinase (eEF2K inhibitors may aid in the development of new therapeutic agents to combat cancer. Purified human eEF2K was obtained from an Escherichia coli expression system and a luminescence-based high-throughput screening (HTS assay was developed using MH-1 peptide as the substrate. The luminescent readouts correlated with the amount of adenosine triphosphate remaining in the kinase reaction. This method was applied to a large-scale screening campaign against a diverse compound library and subsequent confirmation studies. Nine initial hits showing inhibitory activities on eEF2K were identified from 56,000 synthetic compounds during the HTS campaign, of which, five were chosen to test their effects in cancer cell lines.

  4. Thermometric enzyme linked immunosorbent assay: TELISA.

    Science.gov (United States)

    Mattiasson, B; Borrebaeck, C; Sanfridson, B; Mosbach, K

    1977-08-11

    A new method, thermometric enzyme linked immunosorbent assay (TELISA), for the assay of endogenous and exogenous compounds in biological fluids is described. It is based on the previously described enzyme linked immunosorbent assay technique, ELISA, but utilizes enzymic heat formation which is measured in an enzyme thermistor unit. In the model system studied determination of human serum albumin down to a concentration of 10(-10) M (5 ng/ml) was achieved, with both normal and catalase labelled human serum albumin competing for the binding sites on the immunosorbent, which was rabbit antihuman serum albumin immobilized onto Sepharose CL-4B.

  5. Cutaneous and visceral leishmaniasis co-infection in dogs from Rio de Janeiro, Brazil: evaluation by specific PCR and RFLP-PCR assays

    Directory of Open Access Journals (Sweden)

    Marize Quinhones Pires

    2014-04-01

    Full Text Available Introduction During a diagnostic evaluation of canine visceral leishmaniasis (VL, two of seventeen dogs were found to be co-infected by Leishmania (Viannia braziliensis and Leishmania (Leishmania chagasi. Methods Specific polymerase chain reaction (PCR and restriction fragment length polymorphism-PCR (RFLP-PCR assays were performed. Results PCR assays for Leishmania subgenus identification followed by RFLP-PCR analysis in biopsies from cutaneous lesions and the spleen confirmed the presence of Leishmania (Viannia braziliensis and Leishmania (Leishmania chagasi in those fragments. Conclusions This report reinforces the importance of using serological and molecular techniques in the epidemiological surveillance of canine populations in endemic areas in which both diseases are known to co-exist. In such cases, a reassessment of the control measures is required.

  6. Collaborative ring trial of the papaya endogenous reference gene and its polymerase chain reaction assays for genetically modified organism analysis.

    Science.gov (United States)

    Wei, Jiaojun; Li, Feiwu; Guo, Jinchao; Li, Xiang; Xu, Junfeng; Wu, Gang; Zhang, Dabing; Yang, Litao

    2013-11-27

    The papaya (Carica papaya L.) Chymopapain (CHY) gene has been reported as a suitable endogenous reference gene for genetically modified (GM) papaya detection in previous studies. Herein, we further validated the use of the CHY gene and its qualitative and quantitative polymerase chain reaction (PCR) assays through an interlaboratory collaborative ring trial. A total of 12 laboratories working on detection of genetically modified organisms participated in the ring trial and returned test results. Statistical analysis of the returned results confirmed the species specificity, low heterogeneity, and single-copy number of the CHY gene among different papaya varieties. The limit of detection of the CHY qualitative PCR assay was 0.1%, while the limit of quantification of the quantitative PCR assay was ∼25 copies of haploid papaya genome with acceptable PCR efficiency and linearity. The differences between the tested and true values of papaya content in 10 blind samples ranged from 0.84 to 6.58%. These results indicated that the CHY gene was suitable as an endogenous reference gene for the identification and quantification of GM papaya.

  7. Use of enzyme-linked immunosorbent assay and dipstick assay for detection of Strongyloides stercoralis infection in humans

    NARCIS (Netherlands)

    van Doorn, H. Rogier; Koelewijn, Rob; Hofwegen, Henk; Gilis, Henk; Wetsteyn, Jose C. F. M.; Wismans, Pieter J.; Sarfati, Claudine; Vervoort, Tony; van Gool, Tom

    2007-01-01

    A homemade enzyme-linked immunosorbent assay (ELISA) (Academic Medical Center ELISA [AMC-ELISA]) and a dipstick assay for the detection of anti-Strongyloides stercoralis antibodies in serum were developed and evaluated together with two commercially available ELISAs (IVD-ELISA [IVD Research, Inc.

  8. Feasibility Study of Neutron Multiplicity Assay for a Heterogeneous Sludge Sample containing Na, Pu and other Impurities

    International Nuclear Information System (INIS)

    Nakamura, H.; Nakamichi, H.; Mukai, Y.; Yoshimoto, K.; Beddingfield, D.H.

    2010-01-01

    To reduce radioactivity of liquid waste generated at PCDF, a neutralization precipitation processes of radioactive nuclides by sodium hydroxide is used. We call the precipitate a 'sludge' after calcination. Pu mass in the sludge is normally determined by sampling and DA within the required uncertainty on DIQ. Annual yield of the mass is small but it accumulates and reaches to a few kilograms, so it is declared as retained waste and verified at PIV. A HM-5-based verification is applied for sludge verification. The sludge contains many chemical components. For example, Pu (-10wt%), U, Am, SUS components, halogens, NaNO 3 (main component), residual NaOH, and moisture. They are mixed together as an impure heterogeneous sludge sample. As a result, there is a large uncertainty in the sampling and DA that is currently used at PCDF. In order to improve the material accounting, we performed a feasibility study using neutron multiplicity assay for impure sludge samples. We have measured selected sludge samples using a multiplicity counter which is called FCAS (Fast Carton Assay System) which was designed by JAEA and Canberra. The PCDF sludge materials fall into the category of 'difficult to measure' because of the high levels of impurities, high alpha values and somewhat small Pu mass. For the sludge measurements, it was confirmed that good consistency between Pu mass in a pure sludge standard (PuO 2 -Na 2 U 2 O 7 , alpha=7) and the DA could be obtained. For unknown samples, using 14-hour measurements, we could obtain quite low statistical uncertainty on Doubles (-1%) and Triples (-10%) count rate although the alpha value was extremely high (15-25) and FCAS efficiency was relatively low (40%) for typical multiplicity counters. Despite the detector efficiency challenges and the material challenges (high alpha, low Pu mass, heterogeneous matrix), we have been able to obtain assay results that greatly exceed the accountancy requirements for retained waste materials. We have

  9. Accuracy of a dual path platform (DPP assay for the rapid point-of-care diagnosis of human leptospirosis.

    Directory of Open Access Journals (Sweden)

    Scott A Nabity

    Full Text Available Diagnosis of leptospirosis by the gold standard serologic assay, the microscopic agglutination test (MAT, requires paired sera and is not widely available. We developed a rapid assay using immunodominant Leptospira immunoglobulin-like (Lig proteins in a Dual Path Platform (DPP. This study aimed to evaluate the assay's diagnostic performance in the setting of urban transmission.We determined test sensitivity using 446 acute and convalescent sera from MAT-confirmed case-patients with severe or mild leptospirosis in Brazil. We assessed test specificity using 677 sera from the following groups: healthy residents of a Brazilian slum with endemic transmission, febrile outpatients from the same slum, healthy blood donors, and patients with dengue, hepatitis A, and syphilis. Three operators independently interpreted visual results without knowing specimen status.The overall sensitivity for paired sera was 100% and 73% for severe and mild disease, respectively. In the acute phase, the assay achieved a sensitivity of 85% and 64% for severe and mild leptospirosis, respectively. Within seven days of illness onset, the assay achieved a sensitivity of 77% for severe disease and 60% for mild leptospirosis. Sensitivity of the DPP assay was similar to that for IgM-ELISA and increased with both duration of symptoms (chi-square regression P = 0.002 and agglutinating titer (Spearman ρ = 0.24, P<0.001. Specificity was ≥93% for dengue, hepatitis A, syphilis, febrile outpatients, and blood donors, while it was 86% for healthy slum residents. Inter-operator agreement ranged from very good to excellent (kappa: 0.82-0.94 and test-to-test reproducibility was also high (kappa: 0.89.The DPP assay performed acceptably well for diagnosis of severe acute clinical leptospirosis and can be easily implemented in hospitals and health posts where leptospirosis is a major public health problem. However, test accuracy may need improvement for mild disease and early stage

  10. Development of the Performance Confirmation Program at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    G.D. LeCain; D. Barr; D. Weaver; R. Snell; S.W. Goodin; F.D. Hansen

    2006-01-01

    The Yucca Mountain Performance Confirmation program consists of tests, monitoring activities, experiments, and analyses to evaluate the adequacy of assumptions, data, and analyses that form the basis of the conceptual and numerical models of flow and transport associated with a proposed radioactive waste repository at Yucca Mountain, Nevada. The Performance Confirmation program uses an eight-stage risk-informed, performance-based approach. Selection of the Performance Confirmation activities (a parameter and a test method) for inclusion in the Performance Confirmation program was done using a risk-informed performance-based decision analysis. The result of this analysis and review was a Performance Confirmation base portfolio that consists of 20 activities. The 20 Performance Confirmation activities include geologic, hydrologic, and construction/engineering testing. Several of the activities were initiated during site characterization and are ongoing. Others activities will commence during construction and/or post emplacement and will continue until repository closure

  11. Parallel force assay for protein-protein interactions.

    Science.gov (United States)

    Aschenbrenner, Daniela; Pippig, Diana A; Klamecka, Kamila; Limmer, Katja; Leonhardt, Heinrich; Gaub, Hermann E

    2014-01-01

    Quantitative proteome research is greatly promoted by high-resolution parallel format assays. A characterization of protein complexes based on binding forces offers an unparalleled dynamic range and allows for the effective discrimination of non-specific interactions. Here we present a DNA-based Molecular Force Assay to quantify protein-protein interactions, namely the bond between different variants of GFP and GFP-binding nanobodies. We present different strategies to adjust the maximum sensitivity window of the assay by influencing the binding strength of the DNA reference duplexes. The binding of the nanobody Enhancer to the different GFP constructs is compared at high sensitivity of the assay. Whereas the binding strength to wild type and enhanced GFP are equal within experimental error, stronger binding to superfolder GFP is observed. This difference in binding strength is attributed to alterations in the amino acids that form contacts according to the crystal structure of the initial wild type GFP-Enhancer complex. Moreover, we outline the potential for large-scale parallelization of the assay.

  12. Analysis of irregularly distributed points

    DEFF Research Database (Denmark)

    Hartelius, Karsten

    1996-01-01

    conditional modes are applied to this problem. The Kalman filter is described as a powerfull tool for modelling two-dimensional data. Motivated by the development of the reduced update Kalman filter we propose a reduced update Kalman smoother which offers considerable computa- tional savings. Kriging...... on hybridisation analysis, which comprise matching a grid to an arrayed set of DNA- clones spotted onto a hybridisation filter. The line process has proven to perform a satisfactorly modelling of shifted fields (subgrids) in the hybridisation grid, and a two-staged hierarchical grid matching scheme which...

  13. Linearization of the bradford protein assay.

    Science.gov (United States)

    Ernst, Orna; Zor, Tsaffrir

    2010-04-12

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, the ratio of the absorbance measurements at 590 nm and 450 nm is strictly linear with protein concentration. This simple procedure increases the accuracy and improves the sensitivity of the assay about 10-fold, permitting quantification down to 50 ng of bovine serum albumin. Furthermore, the interference commonly introduced by detergents that are used to create the cell lysates is greatly reduced by the new protocol. A linear equation developed on the basis of mass action and Beer's law perfectly fits the experimental data.

  14. Nondestructive assay of HTGR fuel rods

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1974-01-01

    Performance characteristics of three different radioactive source NDA systems are compared for the assay of HTGR fuel rods and stacks of rods. These systems include the fast neutron Sb-Be assay system, the 252 Cf ''Shuffler,'' and the thermal neutron PAPAS assay system. Studies have been made to determinethe perturbation on the measurements from particle size, kernel Th/U ratio, thorium content, and hydrogen content. In addition to the total 235 U determination, the pellet-to-pellet or rod-to-rod uniformity of HTGR fuel rod stacks has been measured by counting the delayed gamma rays with a NaI through-hole in the PAPAS system. These measurements showed that rod substitutions can be detected easily in a fuel stack, and that detailed information is available on the loading variations in a uniform stack. Using a 1.0 mg 252 Cf source, assay rates of 2 to 4 rods/s are possible, thus facilitating measurement of 100 percent of a plant's throughput. (U.S.)

  15. Barcoded microchips for biomolecular assays.

    Science.gov (United States)

    Zhang, Yi; Sun, Jiashu; Zou, Yu; Chen, Wenwen; Zhang, Wei; Xi, Jianzhong Jeff; Jiang, Xingyu

    2015-01-20

    Multiplexed assay of analytes is of great importance for clinical diagnostics and other analytical applications. Barcode-based bioassays with the ability to encode and decode may realize this goal in a straightforward and consistent manner. We present here a microfluidic barcoded chip containing several sets of microchannels with different widths, imitating the commonly used barcode. A single barcoded microchip can carry out tens of individual protein/nucleic acid assays (encode) and immediately yield all assay results by a portable barcode reader or a smartphone (decode). The applicability of a barcoded microchip is demonstrated by human immunodeficiency virus (HIV) immunoassays for simultaneous detection of three targets (anti-gp41 antibody, anti-gp120 antibody, and anti-gp36 antibody) from six human serum samples. We can also determine seven pathogen-specific oligonucleotides by a single chip containing both positive and negative controls.

  16. Performance characteristics of the ARCHITECT anti-HCV assay.

    Science.gov (United States)

    Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter

    2005-10-01

    The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.

  17. Short communication. Microculture syncytia assay for bovine leukemia virus

    Energy Technology Data Exchange (ETDEWEB)

    Paul, P.S.; Castro, A.E.; Pomeroy, K.A.; Johnson, D.W.; Muscoplat, C.C.

    1978-01-01

    A microculture syncytia assay for the detection of bovine leukemia virus (BLV) has been described and compared with the conventional macroculture assay. The microculture assay required fewer indicator cells, was as sensitive as the macroculture assay and provided a reproducible test for the detection and titration of BLV.

  18. In situ hybridisation of a large repertoire of muscle-specific transcripts in fish larvae: the new superficial slow-twitch fibres exhibit characteristics of fast-twitch differentiation.

    Science.gov (United States)

    Chauvigné, F; Ralliere, C; Cauty, C; Rescan, P Y

    2006-01-01

    Much of the present information on muscle differentiation in fish concerns the early embryonic stages. To learn more about the maturation and the diversification of the fish myotomal fibres in later stages of ontogeny, we investigated, by means of in situ hybridisation, the developmental expression of a large repertoire of muscle-specific genes in trout larvae from hatching to yolk resorption. At hatching, transcripts for fast and slow muscle protein isoforms, namely myosins, tropomyosins, troponins and myosin binding protein C were present in the deep fast and the superficial slow areas of the myotome, respectively. During myotome expansion that follows hatching, the expression of fast isoforms became progressively confined to the borders of the fast muscle mass, whereas, in contrast, slow muscle isoform transcripts were uniformly expressed in all the slow fibres. Transcripts for several enzymes involved in oxidative metabolism such as citrate synthase, cytochrome oxidase component IV and succinate dehydrogenase, were present throughout the whole myotome of hatching embryos but in later stages became concentrated in slow fibre as well as in lateral fast fibres. Surprisingly, the slow fibres that are added externally to the single superficial layer of the embryonic (original) slow muscle fibres expressed not only slow twitch muscle isoforms but also, transiently, a subset of fast twitch muscle isoforms including MyLC1, MyLC3, MyHC and myosin binding protein C. Taken together these observations show that the growth of the myotome of the fish larvae is associated with complex patterns of muscular gene expression and demonstrate the unexpected presence of fast muscle isoform-expressing fibres in the most superficial part of the slow muscle.

  19. 21 CFR 864.7525 - Heparin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Heparin assay. 864.7525 Section 864.7525 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7525 Heparin assay. (a) Identification. A...

  20. Suitability of a liquid chromatography assay of neomycin sulfate to replace the microbiological assay for neomycin in USP Monographs.

    Science.gov (United States)

    Hanko, Valoran P; Rohrer, Jeffrey S

    2010-01-05

    The current USP National Formulary contains 65 Monographs for drug formulations containing neomycin. All 65 Monographs prescribe a bioassay for neomycin assay. This bioassay, based on cell culture, is labor intensive, has poor precision, and cannot be adapted for purity or identification. High-performance anion-exchange chromatography with integrated pulsed amperometric detection (HPAE-IPAD), a liquid chromatography technique, has been shown to be suitable for neomycin purity analysis and neomycin assay of an over-the-counter first aid cream (Hanko and Rohrer [17]). Here we propose that an HPAE-IPAD assay can replace the bioassay in the 65 neomycin-containing Monographs. We applied the HPAE-IPAD assay to four neomycin-containing drug products representing the four classes of formulations found in the 65 Monographs, liquid, solid, suspension, and cream. Each drug was analyzed with two chromatography systems, and on 3 separate days. For all products, HPAE-IPAD measurements were precise and accurate with respect to the label concentrations. There was also high accuracy for spike recovery of neomycin from the four drug products throughout 70-150% of the labeled concentration. These results suggest that an HPAE-IPAD assay would be an accurate assay for neomycin, and would be faster and more precise than the current bioassay.