WorldWideScience

Sample records for hybrid infusion method

  1. Vacuum infusion method for woven carbon/Kevlar reinforced hybrid composite

    Science.gov (United States)

    Hashim, N.; Majid, D. L.; Uda, N.; Zahari, R.; Yidris, N.

    2017-12-01

    The vacuum assisted resin transfer moulding (VaRTM) or Vacuum Infusion (VI) is one of the fabrication methods used for composite materials. Compared to other methods, this process costs lower than using prepregs because it does not need to use the autoclave to cure. Moreover, composites fabricated using this VI method exhibit superior mechanical properties than those made through hand layup process. In this study, the VI method is used in fabricating woven carbon/Kevlar fibre cloth with epoxy matrix. This paper reports the detailed methods on fabricating the hybrid composite using VI process and several precautions that need to be taken to avoid any damage to the properties of the composite material. The result highlights that the successfully fabricated composite has approximately 60% of fibres weight fraction. Since the composites produced by the VI process have a higher fibre percentage, this process should be considered for composites used in applications that are susceptible to the conditions where the fibres need to be the dominant element such as in tension loading.

  2. Mechanical properties and production quality of hand-layup and vacuum infusion processed hybrid composite materials for GFRP marine structures

    Science.gov (United States)

    Kim, Sang-Young; Shim, Chun Sik; Sturtevant, Caleb; Kim, Dave (Dae-Wook); Song, Ha Cheol

    2014-09-01

    Glass Fiber Reinforced Plastic (GFRP) structures are primarily manufactured using hand lay-up or vacuum infusion techniques, which are cost-effective for the construction of marine vessels. This paper aims to investigate the mechanical properties and failure mechanisms of the hybrid GFRP composites, formed by applying the hand lay-up processed exterior and the vacuum infusion processed interior layups, providing benefits for structural performance and ease of manufacturing. The hybrid GFRP composites contain one, two, and three vacuum infusion processed layer sets with consistent sets of hand lay-up processed layers. Mechanical properties assessed in this study include tensile, compressive and in-plane shear properties. Hybrid composites with three sets of vacuum infusion layers showed the highest tensile mechanical properties while those with two sets had the highest mechanical properties in compression. The batch homogeneity, for the GFRP fabrication processes, is evaluated using the experimentally obtained mechanical properties

  3. Mechanical properties and production quality of hand-layup and vacuum infusion processed hybrid composite materials for GFRP marine structures

    Directory of Open Access Journals (Sweden)

    Kim Sang-Young

    2014-09-01

    Full Text Available Glass Fiber Reinforced Plastic (GFRP structures are primarily manufactured using hand lay-up or vacuum infusion techniques, which are cost-effective for the construction of marine vessels. This paper aims to investigate the mechanical properties and failure mechanisms of the hybrid GFRP composites, formed by applying the hand lay-up processed exterior and the vacuum infusion processed interior layups, providing benefits for structural performance and ease of manufacturing. The hybrid GFRP composites contain one, two, and three vacuum infusion processed layer sets with consistent sets of hand lay-up processed layers. Mechanical properties assessed in this study include tensile, compressive and in-plane shear properties. Hybrid composites with three sets of vacuum infusion layers showed the highest tensile mechanical properties while those with two sets had the highest mechanical properties in compression. The batch homogeneity, for the GFRP fabrication processes, is evaluated using the experimentally obtained mechanical properties

  4. Mechanical properties and production quality of hand-layup and vacuum infusion processed hybrid composite materials for GFRP marine structures

    Directory of Open Access Journals (Sweden)

    Sang-Young Kim

    2014-09-01

    Full Text Available Glass Fiber Reinforced Plastic (GFRP structures are primarily manufactured using hand lay-up or vacuum infusion techniques, which are cost-effective for the construction of marine vessels. This paper aims to investigate the mechanical properties and failure mechanisms of the hybrid GFRP composites, formed by applying the hand lay-up processed exterior and the vacuum infusion processed interior layups, providing benefits for structural performance and ease of manufacturing. The hybrid GFRP composites contain one, two, and three vacuum infusion processed layer sets with consistent sets of hand lay-up processed layers. Mechanical properties assessed in this study include tensile, compressive and in-plane shear properties. Hybrid composites with three sets of vacuum infusion layers showed the highest tensile mechanical properties while those with two sets had the highest mechanical properties in compression. The batch homogeneity, for the GFRP fabrication processes, is evaluated using the experimentally obtained mechanical properties.

  5. Comparison of infusion pumps calibration methods

    Science.gov (United States)

    Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia

    2017-12-01

    Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.

  6. Comparison of the intracoronary continuous infusion method using a microcatheter and the intravenous continuous adenosine infusion method for inducing maximal hyperemia for fractional flow reserve measurement.

    Science.gov (United States)

    Yoon, Myeong-Ho; Tahk, Seung-Jea; Yang, Hyoung-Mo; Park, Jin-Sun; Zheng, Mingri; Lim, Hong-Seok; Choi, Byoung-Joo; Choi, So-Yeon; Choi, Un-Jung; Hwang, Joung-Won; Kang, Soo-Jin; Hwang, Gyo-Seung; Shin, Joon-Han

    2009-06-01

    Inducing stable maximal coronary hyperemia is essential for measurement of fractional flow reserve (FFR). We evaluated the efficacy of the intracoronary (IC) continuous adenosine infusion method via a microcatheter for inducing maximal coronary hyperemia. In 43 patients with 44 intermediate coronary lesions, FFR was measured consecutively by IC bolus adenosine injection (48-80 microg in left coronary artery, 36-60 microg in the right coronary artery) and a standard intravenous (IV) adenosine infusion (140 microg x min(-1) x kg(-1)). After completion of the IV infusion method, the tip of an IC microcatheter (Progreat Microcatheter System, Terumo, Japan) was positioned at the coronary ostium, and FFR was measured with increasing IC continuous adenosine infusion rates from 60 to 360 microg/min via the microcatheter. Fractional flow reserve decreased with increasing IC adenosine infusion rates, and no further decrease was observed after 300 microg/min. All patients were well tolerated during the procedures. Fractional flow reserves measured by IC adenosine infusion with 180, 240, 300, and 360 microg/min were significantly lower than those by IV infusion (P < .05). Intracoronary infusion at 180, 240, 300, and 360 microg/min was able to shorten the times to induction of optimal and steady-stable hyperemia compared to IV infusion (P < .05). Functional significances were changed in 5 lesions by IC infusion at 240 to 360 microg/min but not by IV infusion. The results of this study suggest that an IC adenosine continuous infusion method via a microcatheter is safe and effective in inducing steady-state hyperemia and more potent and quicker in inducing optimal hyperemia than the standard IV infusion method.

  7. Use of a variable tracer infusion method to determine glucose turnover in humans

    International Nuclear Information System (INIS)

    Molina, J.M.; Baron, A.D.; Edelman, S.V.; Brechtel, G.; Wallace, P.; Olefsky, J.M.

    1990-01-01

    The single-compartment pool fraction model, when used with the hyperinsulinemic glucose clamp technique to measure rates of glucose turnover, sometimes underestimates true rates of glucose appearance (Ra) resulting in negative values for hepatic glucose output (HGO). We focused our attention on isotope discrimination and model error as possible explanations for this underestimation. We found no difference in [3-3H] glucose specific activity in samples obtained simultaneously from the femoral artery and vein (2,400 +/- 455 vs. 2,454 +/- 522 dpm/mg) in 6 men during a hyperinsulinemic euglycemic clamp study where insulin was infused at 40 mU.m-2.min-1 for 3 h; therefore, isotope discrimination did not occur. We compared the ability of a constant (0.6 microCi/min) vs. variable tracer infusion method (tracer added to the glucose infusate) to measure non-steady-state Ra during hyperinsulinemic clamp studies. Plasma specific activity fell during the constant tracer infusion studies but did not change from base line during the variable tracer infusion studies. By maintaining a constant plasma specific activity the variable tracer infusion method eliminates uncertainty about changes in glucose pool size. This overcame modeling error and more accurately measures non-steady-state Ra (P less than 0.001 by analysis of variance vs. constant infusion method). In conclusion, underestimation of Ra determined isotopically during hyperinsulinemic clamp studies is largely due to modeling error that can be overcome by use of the variable tracer infusion method. This method allows more accurate determination of Ra and HGO under non-steady-state conditions

  8. Assessment of right liver graft perfusion effectiveness between one and two-catheter infusion methods.

    Science.gov (United States)

    Jung, Bo-Hyun; Hwang, Shin; Ha, Tae-Yong; Song, Gi-Won; Jung, Dong-Hwan; Kim, Ki-Hun; Ahn, Chul-Soo; Moon, Deok-Bog; Park, Gil-Chun; Kang, Sung-Hwa; Yoon, Young-In; Lee, Sung-Gyu

    2014-05-01

    Conventional graft perfusion method using one small-caliber catheter takes a relatively long time for right liver graft perfusion, thus some modification is needed. In this study, we intended to assess the effectiveness of right liver graft perfusion methods through comparison of different infusion catheters. The study consisted of two parts including one bench experiment to obtain data of hydraulic infusion and one clinical trial of 40 cases on graft perfusion with one- versus two-catheter infusion methods. These two graft infusion methods were compared in terms of the perfusion time and washing-out efficiency. At bench experiment, the infusion flow rate and infusion pressure were 3.3 ml/sec and 1.9 cmH20 in one blood transfusion catheter group, and 11.7 ml/sec and 3.1 cmH20 in single transurethral resection of prostate irrigation catheter group, and 6.6 ml/sec and 2.0 cmH20 in two blood transfusion catheters group, respectively. In clinical trial with 40 right liver grafts, two-catheter group had a shorter graft portal perfusion time for the first 2 L of histidine-tryptophan-ketoglutarate (HTK) solution than the conventional one-catheter group (375±25 seconds vs. 662±34 seconds; p=0.001) and a lower rate of incomplete blood washing-out after the initial 2 L portal perfusion (40% vs. 85%; p=0.03). The two-catheter infusion method appears to be more effective than the conventional one-catheter infusion method for right liver graft perfusion at the back table. Large size of right liver grafts seems to be its good indication.

  9. Infusion Extractor

    Science.gov (United States)

    Chang-Diaz, Franklin R.

    1988-01-01

    Apparatus and method of removing desirable constituents from an infusible material by infusion extraction, where a piston operating in a first chamber draws a solvent into the first chamber where it may be heated, and then moves the heated solvent into a second chamber containing the infusible material, and where infusion extraction takes place. The piston then moves the solvent containing the extract through a filter into the first chamber, leaving the extraction residue in the second chamber.

  10. Resin infusion of layered metal/composite hybrid and resulting metal/composite hybrid laminate

    Science.gov (United States)

    Cano, Roberto J. (Inventor); Grimsley, Brian W. (Inventor); Weiser, Erik S. (Inventor); Jensen, Brian J. (Inventor)

    2009-01-01

    A method of fabricating a metal/composite hybrid laminate is provided. One or more layered arrangements are stacked on a solid base to form a layered structure. Each layered arrangement is defined by a fibrous material and a perforated metal sheet. A resin in its liquid state is introduced along a portion of the layered structure while a differential pressure is applied across the laminate structure until the resin permeates the fibrous material of each layered arrangement and fills perforations in each perforated metal sheet. The resin is cured thereby yielding a metal/composite hybrid laminate.

  11. Low flow measurement for infusion pumps: implementation and uncertainty determination of the normalized method

    International Nuclear Information System (INIS)

    Cebeiro, J; Musacchio, A; Sardá, E Fernández

    2011-01-01

    Intravenous drug delivery is a standard practice in hospitalized patients. As the blood concentration reached depends directly on infusion rate, it is important to use safe devices that guarantee output accuracy. In pediatric intensive care units, low infusion rates (i.e. lower than 10.0 ml/h) are frequently used. Thus, it would be necessary to use control programs to search for deviations at this flow range. We describe the implementation of a gravimetric method to test infusion pumps in low flow delivery. The procedure recommended by the ISO/IEC 60601-2-24 standard was used being a reasonable option among the methods frequently used in hospitals, such as infusion pumps analyzers and volumetric cylinders. The main uncertainty sources affecting this method are revised and a numeric and graphic uncertainty analysis is presented in order to show its dependence on flow. Additionally, the obtained uncertainties are compared to those presented by an automatic flow analyzer. Finally, the results of a series of tests performed on a syringe infusion pump operating at low rates are shown.

  12. Measuring Protein Synthesis Rate In Living Object Using Flooding Dose And Constant Infusion Methods

    OpenAIRE

    Ulyarti, Ulyarti

    2018-01-01

    Constant infusion is a method used for measuring protein synthesis rate in living object which uses low concentration of amino acid tracers. Flooding dose method is another technique used to measure the rate of protein synthesis which uses labelled amino acid together with large amount of unlabelled amino acid.  The latter method was firstly developed to solve the problem in determination of precursor pool arise from constant infusion method.  The objective of this writing is to com...

  13. Infusion volume control and calculation using metronome and drop counter based intravenous infusion therapy helper.

    Science.gov (United States)

    Park, Kyungnam; Lee, Jangyoung; Kim, Soo-Young; Kim, Jinwoo; Kim, Insoo; Choi, Seung Pill; Jeong, Sikyung; Hong, Sungyoup

    2013-06-01

    This study assessed the method of fluid infusion control using an IntraVenous Infusion Controller (IVIC). Four methods of infusion control (dial flow controller, IV set without correction, IV set with correction and IVIC correction) were used to measure the volume of each technique at two infusion rates. The infused fluid volume with a dial flow controller was significantly larger than other methods. The infused fluid volume was significantly smaller with an IV set without correction over time. Regarding the concordance correlation coefficient (CCC) of infused fluid volume in relation to a target volume, IVIC correction was shown to have the highest level of agreement. The flow rate measured in check mode showed a good agreement with the volume of collected fluid after passing through the IV system. Thus, an IVIC could assist in providing an accurate infusion control. © 2013 Wiley Publishing Asia Pty Ltd.

  14. Mechanical characterisation of hybrid composite laminates based on basalt fibres in combination with flax, hemp and glass fibres manufactured by vacuum infusion

    International Nuclear Information System (INIS)

    Petrucci, R.; Santulli, C.; Puglia, D.; Sarasini, F.; Torre, L.; Kenny, J.M.

    2013-01-01

    Highlights: ► For the first time, hybrid laminates with three different fibres were produced. ► Concerns are confirmed on the brittleness of hybrid laminates with basalt fibre core. ► An optimal configuration (FHB) for flexural properties was singled out. ► Differences between tensile and flexural properties of hybrids were identified. ► In general, the specific mechanical properties of the hybrids are quite high. - Abstract: This work concerns the production by vacuum infusion and the comparison of the properties of different hybrid composite laminates, based on basalt fibre composites as the inner core, and using also glass, flax and hemp fibre laminates to produce symmetrical configurations, all of them with a 21–23% fibre volume, in an epoxy resin. The laminates have been subjected to tensile, three-point flexural and interlaminar shear strength tests and their fracture surfaces have been characterised by scanning electron microscopy. The mechanical performance of all the hybrid laminates appears superior to pure hemp and flax fibre reinforced laminates and inferior to basalt fibre laminates. Among the hybrids, the best properties are offered by those obtained by adding glass and flax to basalt fibre reinforced laminates. Scanning electron microscopy (SEM) observation of hybrid laminates showed the diffuse presence of fibre pull-out in hemp and flax fibre reinforced layers and a general trend of brittle failure

  15. Doing Business with China: Curriculum Internationalisation through an Infusion Method

    Science.gov (United States)

    Jin, Byoungho; Swinney, Jane; Cao, Huantian; Muske, Glenn; Nam, Jinhee; Kang, Ji Hye

    2011-01-01

    The US apparel and textiles industry operates within an interdependent global system, necessitating workforces competent for day-to-day operations. The US workforce lacks preparedness in working globally; this study tests an infusion method of curriculum internationalisation to enhance students' global understanding. Four cognitive and…

  16. Infusion MR arteriography during hepatic arterial infusion chemotherapy. Evaluation of clinical usefulness

    International Nuclear Information System (INIS)

    Uchino, Minako; Takizawa, Kenji

    2003-01-01

    We developed a new method of infusion MR arteriography (IMRA) via an implantable port system using an infusion pump for the evaluation of drug distribution during hepatic arterial infusion chemotherapy. The purposes of this study were to optimize the method and evaluate its clinical usefulness. We used 3D-T1 turbo field echo (TFE) as the most suitable sequence for IMRA according to the results of a phantom model experiment. We examined 33 cases of liver cancer that had been treated by arterial infusion chemotherapy via the port system. The following investigations were performed: degree of tumor enhancement, intra- and extra- hepatic perfusion abnormality, and related toxicity. The evaluation of images was performed separately by two radiologists. IMRA provided good images of contrast enhancement, to reveal the perfusion patterns. The treatment response rate in the tumor group with well enhancement was higher than that of the group with poor enhancement (p<0.0001). Extrahepatic perfusion was well visualized and was correlated with toxicity (p<0.0001). IMRA is a useful method to evaluate drug perfusion for the optimization of arterial infusion chemotherapy. (author)

  17. A magnetic-based dispersive micro-solid-phase extraction method using the metal-organic framework HKUST-1 and ultra-high-performance liquid chromatography with fluorescence detection for determining polycyclic aromatic hydrocarbons in waters and fruit tea infusions.

    Science.gov (United States)

    Rocío-Bautista, Priscilla; Pino, Verónica; Ayala, Juan H; Pasán, Jorge; Ruiz-Pérez, Catalina; Afonso, Ana M

    2016-03-04

    A hybrid material composed by the metal-organic framework (MOF) HKUST-1 and Fe3O4 magnetic nanoparticles (MNPs) has been synthetized in a quite simple manner, characterized, and used in a magnetic-assisted dispersive micro-solid-phase extraction (M-d-μSPE) method in combination with ultra-high-performance liquid chromatography (UHPLC) and fluorescence detection (FD). The application was devoted to the determination of 8 heavy polycyclic aromatic hydrocarbons (PAHs) in different aqueous samples, specifically tap water, wastewaters, and fruit tea infusion samples. The overall M-d-μSPE-UHPLC-FD method was optimized and validated. The method is characterized by: its simplicity in both the preparation of the hybrid material (simple mixing) and the magnetic-assisted approach (∼10min extraction time), the use of low sorbent amounts (20mg of HKUST-1 and 5mg of Fe3O4 MNPs), and the low organic solvent consumption in the overall M-d-μSPE-UHPLC-FD method (1.5mL of acetonitrile in the M-d-μSPE method and 2.8mL of acetonitrile in the UHPLC-FD run). The resulting method has high sensitivity, with LODs down to 0.8ngL(-1); adequate intermediate precision, with relative standard deviation values (RSD) always lower than 6.3% (being the range 5.9-9.0% in tap water for a spiked level of 45ngL(-1), 6.1-14% in wastewaters for a spiked level of 45ngL(-1), and 7.2-17% in fruit tea infusion samples for a spiked level of 45ngL(-1)); and adequate relative recoveries, with average values of 82% in tap water, and 94% and 75% in wastewater and fruit tea infusion samples, respectively, if using the proper matrix-matched calibration. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Direct infusion-SIM as fast and robust method for absolute protein quantification in complex samples

    Directory of Open Access Journals (Sweden)

    Christina Looße

    2015-06-01

    Full Text Available Relative and absolute quantification of proteins in biological and clinical samples are common approaches in proteomics. Until now, targeted protein quantification is mainly performed using a combination of HPLC-based peptide separation and selected reaction monitoring on triple quadrupole mass spectrometers. Here, we show for the first time the potential of absolute quantification using a direct infusion strategy combined with single ion monitoring (SIM on a Q Exactive mass spectrometer. By using complex membrane fractions of Escherichia coli, we absolutely quantified the recombinant expressed heterologous human cytochrome P450 monooxygenase 3A4 (CYP3A4 comparing direct infusion-SIM with conventional HPLC-SIM. Direct-infusion SIM revealed only 14.7% (±4.1 (s.e.m. deviation on average, compared to HPLC-SIM and a decreased processing and analysis time of 4.5 min (that could be further decreased to 30 s for a single sample in contrast to 65 min by the LC–MS method. Summarized, our simplified workflow using direct infusion-SIM provides a fast and robust method for quantification of proteins in complex protein mixtures.

  19. Hybrid Methods in Designing Sierpinski Gasket Antennas

    Directory of Open Access Journals (Sweden)

    Mudrik Alaydrus

    2010-12-01

    Full Text Available Sierpinki gasket antennas as example of fractal antennas show multiband characteristics. The computer simulation of Sierpinksi gasket monopole with finite ground needs prohibitively large computer memory and more computational time. Hybrid methods consist of surface integral equation method and physical optics or uniform geometrical theory of diffraction should alleviate this computational burdens. The so-called full hybridization of the different methods with modifying the incoming electromagnetic waves in case of hybrid method surface integral equation method and physical optics and modification of the Greens function for hybrid method surface integral equation method and uniform geometrical theory of diffraction plays the central role in the observation. Comparison between results of different methods are given and also measurements of three Sierpinksi gasket antennas. The multiband characteristics of the antennas still can be seen with some reduction and enhancement of resonances.

  20. Hybrid Lanczos-type product methods

    Energy Technology Data Exchange (ETDEWEB)

    Ressel, K.J. [Swiss Center for Scientific Computing, Zuerich (Switzerland)

    1996-12-31

    A general framework is proposed to construct hybrid iterative methods for the solution of large nonsymmetric systems of linear equations. This framework is based on Lanczos-type product methods, whose iteration polynomial consists of the Lanczos polynomial multiplied by some other arbitrary, {open_quotes}shadow{close_quotes} polynomial. By using for the shadow polynomial Chebyshev (more general Faber) polynomials or L{sup 2}-optimal polynomials, hybrid (Chebyshev-like) methods are incorporated into Lanczos-type product methods. In addition, to acquire spectral information on the system matrix, which is required for such a choice of shadow polynomials, the Lanczos-process can be employed either directly or in an QMR-like approach. The QMR like approach allows the cheap computation of the roots of the B-orthogonal polynomials and the residual polynomials associated with the QMR iteration. These roots can be used as a good approximation for the spectrum of the system matrix. Different choices for the shadow polynomials and their construction are analyzed. The resulting hybrid methods are compared with standard Lanczos-type product methods, like BiOStab, BiOStab({ell}) and BiOS.

  1. [Methods of preventing phlebitis induced by infusion of fosaprepitant].

    Science.gov (United States)

    Kohno, Emiko; Kanematsu, Sayaka; Okazaki, Satoshi; Ogata, Makoto; Kanemitsu, Meiko; Yamashita, Hiromi; Syuntou, Kaori; Sekita, Masako; Nishioka, Ryoko; Yoshida, Hideyuki

    2015-03-01

    At our hospital, we use aprepitant for nausea and vomiting when administering highly emetic anticancer agents, according to "Guidelines for the Appropriate Use of Antiemetic Agents" given by the Japan Society of Clinical Oncology. We initiated the intravenous administration of fosaprepitant for better compliance compared with aprepitant; however, we observed phlebitis after the infusion of fosaprepitant. Therefore, we investigated measures to reduce phlebitis associated with the infusion of fosaprepitant. For the first premedication, fosaprepitant (150 mg) was dissolved in 100 mL of saline and administered for 30 minutes; 1 of 2 patients showed grade 4 phlebitis. For the modified premedication, fosaprepitant, dexamethasone, and 5- HT(3) antagonist were dissolved in 100 mL of saline and administered for 30 minutes. The modified premedication was administered to a total of 27 patients; 5 patients developed mild phlebitis (grade 1), but infusion could be continued by treating their phlebitis with a hot pack. We used a combination of dexamethasone and 5-HT(3) antagonist with fosaprepitant as a modified premedication in order to avoid drug-induced vascular damage, which resulted in the pH decreasing to 6.20-7.55 (close to neutral) and a shorter infusion time.

  2. Methods for studying medical device technology and practitioner cognition: the case of user-interface issues with infusion pumps.

    Science.gov (United States)

    Schraagen, Jan Maarten; Verhoeven, Fenne

    2013-02-01

    The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Starting from a Cognitive Systems Engineering perspective, we developed an Impact Flow Diagram showing the relationship of computer technology, cognition, practitioner behavior, and system failure in the area of medical infusion devices. We subsequently conducted a systematic literature review on user-interface issues with infusion pumps, categorized the studies in terms of methods employed, and noted the usability problems found with particular methods. Next, we assigned usability problems and related methods to the levels in the Impact Flow Diagram. Most study methods used to find user interface issues with infusion pumps focused on observable behavior rather than on how artifacts shape cognition and collaboration. A concerted and theory-driven application of these methods when testing infusion pumps is lacking in the literature. Detailed analysis of one case study provided an illustration of how to apply the Impact Flow Diagram, as well as how the scope of analysis may be broadened to include organizational and regulatory factors. Research methods to uncover use problems with technology may be used in many ways, with many different foci. We advocate the adoption of an Impact Flow Diagram perspective rather than merely focusing on usability issues in isolation. Truly advancing patient safety requires the systematic adoption of a systems perspective viewing people and technology as an ensemble, also in the design of medical device technology. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Multiscale Hybrid Micro-Nanocomposites Based on Carbon Nanotubes and Carbon Fibers

    Directory of Open Access Journals (Sweden)

    Fawad Inam

    2010-01-01

    Full Text Available Amino-modified double wall carbon nanotube (DWCNT-NH2/carbon fiber (CF/epoxy hybrid micro-nanocomposite laminates were prepared by a resin infusion technique. DWCNT-NH2/epoxy nanocomposites and carbon fiber/epoxy microcomposites were made for comparison. Morphological analysis of the hybrid composites was performed using field emission scanning electron microscope. A good dispersion at low loadings of carbon nanotubes (CNTs in epoxy matrix was achieved by a bath ultrasonication method. Mechanical characterization of the hybrid micro-nanocomposites manufactured by a resin infusion process included three-point bending, mode I interlaminar toughness, dynamic mechanical analysis, and drop-weight impact testing. The addition of small amounts of CNTs (0.025, 0.05, and 0.1 wt% to epoxy resins for the fabrication of multiscale carbon fiber composites resulted in a maximum enhancement in flexural modulus by 35%, a 5% improvement in flexural strength, a 6% improvement in absorbed impact energy, and 23% decrease in the mode I interlaminar toughness. Hybridization of carbon fiber-reinforced epoxy using CNTs resulted in a reduction in and dampening characteristics, presumably as a result of the presence of micron-sized agglomerates.

  4. Leadership in Dental Hygiene Degree Completion Programs: A Pilot Study Comparing Stand-Alone Leadership Courses and Leadership-Infused Curricula.

    Science.gov (United States)

    Smith, Michelle L; Gurenlian, JoAnn R; Freudenthal, Jacqueline J; Farnsworth, Tracy J

    2016-05-01

    The aim of this study was to define the extent to which leadership and leadership skills are taught in dental hygiene degree completion programs by comparing stand-alone leadership courses/hybrid programs with programs that infuse leadership skills throughout the curricula. The study involved a mixed-methods approach using qualitative and quantitative data. Semi-structured interviews were conducted with program directors and faculty members who teach a stand-alone leadership course, a hybrid program, or leadership-infused courses in these programs. A quantitative comparison of course syllabi determined differences in the extent of leadership content and experiences between stand-alone leadership courses and leadership-infused curricula. Of the 53 U.S. dental hygiene programs that offer degree completion programs, 49 met the inclusion criteria, and 19 programs provided course syllabi. Of the program directors and faculty members who teach a stand-alone leadership course or leadership-infused curriculum, 16 participated in the interview portion of the study. The results suggested that competencies related to leadership were not clearly defined or measurable in current teaching. Reported barriers to incorporating a stand-alone leadership course included overcrowded curricula, limited qualified faculty, and lack of resources. The findings of this study provide a synopsis of leadership content and gaps in leadership education for degree completion programs. Suggested changes included defining a need for leadership competencies and providing additional resources to educators such as courses provided by the American Dental Education Association and the American Dental Hygienists' Association.

  5. Instructors' Growth in TPACK: Teaching Technology-Infused Methods Courses to Preservice Teachers

    Science.gov (United States)

    Foulger, Teresa S.; Buss, Ray R.; Wetzel, Keith; Lindsey, LeeAnn

    2015-01-01

    We were concerned about teaching a stand-alone technology integration course while advocating that teachers employ full integration. Our college moved to a tech-infusion model whereby our educational technology curriculum would be incorporated in methods courses. Using a qualitative approach, we documented experiences of teacher educators who were…

  6. Bronchial arterial infusion versus bronchial combined pulmonary arterial infusion for pulmonary metastatic tumors

    International Nuclear Information System (INIS)

    Dong Sheng; Dong Weihua; Jia Ningyang; Zhang Dianbo; Xiao Xiangsheng

    2008-01-01

    Objective: To evaluate the pulmonary metastatic tumor response to different ways of transcatheter arterial infusion. Methods: Thirty-five patients with pulmonary metastatic tumors were randomized divided into two groups: 15 patients with 49 lesions treated with bronchial arterial infusion (BAI) and 20 patients with 65 lesions treated with bronchial arterial infusion (BM)combined with pulmonary arterial infusion (PAI). The therapeutic response was assessed by the WHO evaluation criteria. Results: The total effective rate(CR + PR) of BAI was 65.3% (32/49), PAI + BAI was 61.5%(40/65) showing no statistical difference. The median survival time of BAI was 9 mo, BAI + PAI was 11.5 mo, demonstrating no statistical significance. Conclusions: BAI should be the primary treatment for pulmonary metastatic tumor. (authors)

  7. Reassessment of primed constant-infusion tracer method to measure urea kinetics

    International Nuclear Information System (INIS)

    Jahoor, F.; Wolfe, R.R.

    1987-01-01

    The validity of the primed constant-infusion tracer technique to make short-term measurements of urea production rates (R/sub a/) in humans in a physiological steady state and during disruption of steady state was evaluated. Four subjects received a primed constant infusion (P/I = 560 min) of [ 13 C]urea for 8 h. A plateau in urea enrichment was reached after 2 h and maintained throughout. When [ 13 C]- and [ 18 O]urea were simultaneously infused into four subjects at P/I ratios of 560:1 and 360:1, respectively, both tracers reached plateau enrichment at the same time (2-4 h). The enrichment at plateau was a function of the infusion rate rather than the priming dose, and calculated urea R/sub a/ was the same with either prime. In five additional experiments the technique responded acutely to a physiological perturbation (alanine infusion) in a dose-dependent manner. The results confirm that this technique is appropriate for short-term measurements of urea R/sub a/, and the requirement for accuracy in estimating the priming dose is not impractically stringent

  8. An audit of hospital based outpatient infusions and a pilot program of community-based monoclonal antibody infusions.

    LENUS (Irish Health Repository)

    Doran, J-P

    2012-02-01

    INTRODUCTION: Infliximab, a chimeric monoclonal antibody to tumour necrosis factor alpha, is administered as an intravenous infusion requiring a costly hospital day case or inpatient admission. METHODS: An audit of all current therapies given by intravenous infusions in an outpatient setting in St Vincent\\'s University Hospital (SVUH) was undertaken. Furthermore, in conjunction with TCP homecare, we established in a general practise health clinic, the first Irish community infusion centre for the administration of infliximab in August 2006. RESULTS: All outpatient departments indicated that they would favour a centralized hospital infusion unit. There were no adverse events and the mean global satisfaction improved in the community infliximab infusion pilot programme of seven patients. CONCLUSION: This study suggests efficiencies in providing centralized infusion facilities, while the community based infusion of infliximab is feasible and safe in this small cohort and identifies the community infusion unit as a viable and cost efficient alternative for administration of infliximab.

  9. Effect of steel and teflon infusion catheters on subcutaneous adipose tissue blood flow and infusion counter pressure in humans

    DEFF Research Database (Denmark)

    Højbjerre, Lise; Skov-Jensen, Camilla; Kaastrup, Peter

    2009-01-01

    BACKGROUND: Subcutaneous tissue is an important target for drug deposition or infusion. A local trauma may induce alterations in local microcirculation and diffusion barriers with consequences for drug bioavailability. We examined the influence of infusion catheters' wear time on local...... microcirculation and infusion counter pressure. METHODS: One steel catheter and one Teflon (Dupont, Wilmington, DE) catheter were inserted in subcutaneous, abdominal adipose tissue (SCAAT) in 10 healthy, lean men. The catheters were infused with isotonic saline at a rate of 10 microL/h for 48 h. Another steel...... catheter and a Teflon catheter were inserted contralateral to the previous catheters after 48 h. The infusion counter pressure was measured during a basal infusion rate followed by a bolus infusion. The measurements during a basal rate infusion were repeated after the bolus infusion. Adipose tissue blood...

  10. The optimal analgesic method in saline infusion sonogram: A comparison of two effective techniques with placebo

    Directory of Open Access Journals (Sweden)

    Sadullah Özkan

    2016-09-01

    Full Text Available Objective: Operations performed with local anesthesia can sometimes be extremely painful and uncomfortable for patients. Our aim was to investigate the optimal analgesic method in saline infusion sonograms.\tMaterials and Methods: This study was performed in our Clinic of Obstetrics and Gynecology between March and August 2011. Ninety-six patients were included. Patients were randomly divided into groups that received saline (controls, group 1, paracervical block (group 2, or paracervical block + intrauterine lidocaine (group 3. In all groups, a visual analogue scale score was performed during the tenaculum placement, while saline was administered, and 30 minutes after the procedure.\tResults: When all the patients were evaluated, the difference in the visual analogue scale scores in premenopausal patients during tenaculum placement, during the saline infusion into the cavity, and 30 minutes following the saline infusion sonography were statistically different between the saline and paracervical block groups, and between the saline and paracervical block + intrauterine lidocaine group. However, there was no statistically significant difference between paracervical block and paracervical block + intrauterine lidocaine groups.\tConclusion: As a result of our study, paracervical block is a safe method to use in premenopausal patients to prevent pain during saline infusion sonography. The addition of intrauterine lidocaine to the paracervical block does not increase the analgesic effect; moreover, it increases the cost and time that the patient stays in the dorsolithotomy position by 3 minutes.

  11. Real-time hybrid simulation using the convolution integral method

    International Nuclear Information System (INIS)

    Kim, Sung Jig; Christenson, Richard E; Wojtkiewicz, Steven F; Johnson, Erik A

    2011-01-01

    This paper proposes a real-time hybrid simulation method that will allow complex systems to be tested within the hybrid test framework by employing the convolution integral (CI) method. The proposed CI method is potentially transformative for real-time hybrid simulation. The CI method can allow real-time hybrid simulation to be conducted regardless of the size and complexity of the numerical model and for numerical stability to be ensured in the presence of high frequency responses in the simulation. This paper presents the general theory behind the proposed CI method and provides experimental verification of the proposed method by comparing the CI method to the current integration time-stepping (ITS) method. Real-time hybrid simulation is conducted in the Advanced Hazard Mitigation Laboratory at the University of Connecticut. A seismically excited two-story shear frame building with a magneto-rheological (MR) fluid damper is selected as the test structure to experimentally validate the proposed method. The building structure is numerically modeled and simulated, while the MR damper is physically tested. Real-time hybrid simulation using the proposed CI method is shown to provide accurate results

  12. Hybrid particles and associated methods

    Science.gov (United States)

    Fox, Robert V; Rodriguez, Rene; Pak, Joshua J; Sun, Chivin

    2015-02-10

    Hybrid particles that comprise a coating surrounding a chalcopyrite material, the coating comprising a metal, a semiconductive material, or a polymer; a core comprising a chalcopyrite material and a shell comprising a functionalized chalcopyrite material, the shell enveloping the core; or a reaction product of a chalcopyrite material and at least one of a reagent, heat, and radiation. Methods of forming the hybrid particles are also disclosed.

  13. Hybrid systems, optimal control and hybrid vehicles theory, methods and applications

    CERN Document Server

    Böhme, Thomas J

    2017-01-01

    This book assembles new methods showing the automotive engineer for the first time how hybrid vehicle configurations can be modeled as systems with discrete and continuous controls. These hybrid systems describe naturally and compactly the networks of embedded systems which use elements such as integrators, hysteresis, state-machines and logical rules to describe the evolution of continuous and discrete dynamics and arise inevitably when modeling hybrid electric vehicles. They can throw light on systems which may otherwise be too complex or recondite. Hybrid Systems, Optimal Control and Hybrid Vehicles shows the reader how to formulate and solve control problems which satisfy multiple objectives which may be arbitrary and complex with contradictory influences on fuel consumption, emissions and drivability. The text introduces industrial engineers, postgraduates and researchers to the theory of hybrid optimal control problems. A series of novel algorithmic developments provides tools for solving engineering pr...

  14. 5th Symposium on Hybrid RANS-LES Methods

    CERN Document Server

    Haase, Werner; Peng, Shia-Hui; Schwamborn, Dieter

    2015-01-01

    This book gathers the proceedings of the Fifth Symposium on Hybrid RANS-LES Methods, which was held on March 19-21 in College Station, Texas, USA. The different chapters, written by leading experts, reports on the most recent developments in flow physics modelling, and gives a special emphasis to industrially relevant applications of hybrid RANS-LES methods and other turbulence-resolving modelling approaches. The book addresses academic researchers, graduate students, industrial engineers, as well as industrial R&D managers and consultants dealing with turbulence modelling, simulation and measurement, and with multidisciplinary applications of computational fluid dynamics (CFD), such as flow control, aero-acoustics, aero-elasticity and CFD-based multidisciplinary optimization. It discusses in particular advanced hybrid RANS-LES methods. Further topics include wall-modelled Large Eddy Simulation (WMLES) methods, embedded LES, and a comparison of the LES methods with both hybrid RANS-LES and URANS methods. ...

  15. Stem infusion of nitrogen-15 to quantify nitrogen remobilization in maize

    International Nuclear Information System (INIS)

    Ma, B.L.; Dwyer, L.M.; Tollenaar, M.; Smith, D.L.

    1998-01-01

    Nitrogen (N) use efficiency (NUE) of fertilizer N can be accurately estimated by tracing the fate of soil applied labelled fertilizer, but the quantity of N remobilization from non-kernel components into kernels in maize (Zea mays L.) plants is difficult to determine. A field experiment involving stem infusion with labelled 15N solution was conducted at Ottawa, Ontario (45 degrees 22'N, 75 degrees 43'W) for two years to determine whether stem infused 15N could be used to quantify N remobilization and the contribution of remobilized N to the grain. A current stay-green commercial hybrid was grown at three fertilizer N rates and infused with 30 mL 15N solution [35.7 mmol N as 15NH(4)15NO(3) at 99.2 15N% atom enrichment (a.e.)] into the internode below the primary cob at anthesis. The control plants were infused with distilled water. Sampling occurred at 3 d, 2 wk and 5 wk after anthesis and at physiological maturity

  16. Application of the photoelastic experimental hybrid method with new numerical method to the high stress distribution

    International Nuclear Information System (INIS)

    Hawong, Jai Sug; Lee, Dong Hun; Lee, Dong Ha; Tche, Konstantin

    2004-01-01

    In this research, the photoelastic experimental hybrid method with Hook-Jeeves numerical method has been developed: This method is more precise and stable than the photoelastic experimental hybrid method with Newton-Rapson numerical method with Gaussian elimination method. Using the photoelastic experimental hybrid method with Hook-Jeeves numerical method, we can separate stress components from isochromatics only and stress intensity factors and stress concentration factors can be determined. The photoelastic experimental hybrid method with Hook-Jeeves had better be used in the full field experiment than the photoelastic experimental hybrid method with Newton-Rapson with Gaussian elimination method

  17. New hybrid conjugate gradient methods with the generalized Wolfe line search.

    Science.gov (United States)

    Xu, Xiao; Kong, Fan-Yu

    2016-01-01

    The conjugate gradient method was an efficient technique for solving the unconstrained optimization problem. In this paper, we made a linear combination with parameters β k of the DY method and the HS method, and putted forward the hybrid method of DY and HS. We also proposed the hybrid of FR and PRP by the same mean. Additionally, to present the two hybrid methods, we promoted the Wolfe line search respectively to compute the step size α k of the two hybrid methods. With the new Wolfe line search, the two hybrid methods had descent property and global convergence property of the two hybrid methods that can also be proved.

  18. Infusion cisternography

    International Nuclear Information System (INIS)

    Magnaes, B.; Rootwelt, K.; Sjaastad, O.

    1976-01-01

    A source of error in cerebrospinal fluid (CSF) infusion tests is leakage at the dural puncture site. The addition of a bolus of radionuclide to the infusion fluid was helpful in detecting the existence of leakage as shown by increased infusion pressure in six of eight patients studied with and without scintigraphic evidence of leakage. Comparison of CSF dynamics in 26 patients studied by infusion cisternography and conventional cisternography showed similar patterns, suggesting no alteration of CSF dynamics by the artificial CSF infusion. Combining the two tests, therefore, resulted in simple identification of the leakage and saved the patient time and discomfort

  19. Development of nondestructive hybrid measuring method for three-dimensional residual stress distribution of thick welded joint. Hybrid measuring method of inherent strain method and neutron diffraction method

    International Nuclear Information System (INIS)

    Nakacho, Keiji; Kasahara, Norifumi; Tamura, Ryota

    2012-01-01

    The measuring methods of the residual stress are classified into destructive one and nondestructive one. The inherent strain method (ISM) is destructive one. The neutron diffraction method (NDM) is nondestructive one. But the measurable depth is limited within about 20 mm and the method cannot measure the weld zone, without destruction of the object. So, in this study, the hybrid measuring method has been developed, by combining the ISM and the NDM. The theory of the hybrid method is the same as the ISM. In the analysis, the strains measured by the NDM without destruction are used. This hybrid measuring method is a true nondestructive measuring method for a thick welded joint. The applicability of the hybrid method has been verified by simulation, using a butt welded joint of thick pipes. In the simulation, the reliable order of the strains measured by the present NDM is very important, and was considered as 10 micro. The measurable regions by the present NDM were assumed. Under the above conditions, the data (the residual elastic strains assumed to be measured by the NDM) were made, and used in the ISM. As a result of such simulation, it has been cleared that the estimated residual stress has very high accuracy, if enough data are used. The required number of data is less than the ISM. (author)

  20. Multiple-time-stepping generalized hybrid Monte Carlo methods

    Energy Technology Data Exchange (ETDEWEB)

    Escribano, Bruno, E-mail: bescribano@bcamath.org [BCAM—Basque Center for Applied Mathematics, E-48009 Bilbao (Spain); Akhmatskaya, Elena [BCAM—Basque Center for Applied Mathematics, E-48009 Bilbao (Spain); IKERBASQUE, Basque Foundation for Science, E-48013 Bilbao (Spain); Reich, Sebastian [Universität Potsdam, Institut für Mathematik, D-14469 Potsdam (Germany); Azpiroz, Jon M. [Kimika Fakultatea, Euskal Herriko Unibertsitatea (UPV/EHU) and Donostia International Physics Center (DIPC), P.K. 1072, Donostia (Spain)

    2015-01-01

    Performance of the generalized shadow hybrid Monte Carlo (GSHMC) method [1], which proved to be superior in sampling efficiency over its predecessors [2–4], molecular dynamics and hybrid Monte Carlo, can be further improved by combining it with multi-time-stepping (MTS) and mollification of slow forces. We demonstrate that the comparatively simple modifications of the method not only lead to better performance of GSHMC itself but also allow for beating the best performed methods, which use the similar force splitting schemes. In addition we show that the same ideas can be successfully applied to the conventional generalized hybrid Monte Carlo method (GHMC). The resulting methods, MTS-GHMC and MTS-GSHMC, provide accurate reproduction of thermodynamic and dynamical properties, exact temperature control during simulation and computational robustness and efficiency. MTS-GHMC uses a generalized momentum update to achieve weak stochastic stabilization to the molecular dynamics (MD) integrator. MTS-GSHMC adds the use of a shadow (modified) Hamiltonian to filter the MD trajectories in the HMC scheme. We introduce a new shadow Hamiltonian formulation adapted to force-splitting methods. The use of such Hamiltonians improves the acceptance rate of trajectories and has a strong impact on the sampling efficiency of the method. Both methods were implemented in the open-source MD package ProtoMol and were tested on a water and a protein systems. Results were compared to those obtained using a Langevin Molly (LM) method [5] on the same systems. The test results demonstrate the superiority of the new methods over LM in terms of stability, accuracy and sampling efficiency. This suggests that putting the MTS approach in the framework of hybrid Monte Carlo and using the natural stochasticity offered by the generalized hybrid Monte Carlo lead to improving stability of MTS and allow for achieving larger step sizes in the simulation of complex systems.

  1. Poly(ethyleneimine) infused and functionalized Torlon®-silica hollow fiber sorbents for post-combustion CO2 capture

    KAUST Repository

    Li, Fuyue Stephanie

    2014-03-01

    Organic-inorganic hybrid materials functionalized with amine-containing reagents are emerging as an important class of materials for capturing carbon dioxide from flue gas. Polymeric silica hollow fiber sorbents are fabricated through the proven dry-jet/wet-quench spinning process. In our study, a new technique for functionalizing polymeric silica hollow fiber sorbents with poly(ethyleneimine), followed by a post-spinning infusion step was studied. This two step process introduces a sufficient amount of poly(ethyleneimine) to the polymeric silica hybrid material support to improve the CO2 sorption capacity due to the added amine groups. The poly(ethyleneimine) infused and functionalized hollow fiber sorbents are also characterized by a thermal gravimetric analyzer (TGA) to assess their CO2 sorption capacities. © 2014 Elsevier Ltd. All rights reserved.

  2. Using higher doses to compensate for tubing residuals in extended-infusion piperacillin-tazobactam.

    Science.gov (United States)

    Lam, Wendy J; Bhowmick, Tanaya; Gross, Alan; Vanschooneveld, Trevor C; Weinstein, Melvin P

    2013-06-01

    To mathematically assess drug losses due to infusion line residuals and evaluate methods to compensate for drug loss due to residual volumes in intravenous pump tubing. Literature was accessed through Ovid MEDLINE (1996-February 2013), using combinations of the search terms tubing residuals, residual volume, residual medication, intravenous infusions, intravenous injections, piperacillin, piperacillin-tazobactam, β-lactams, equipment design, infusion pumps, extended infusion, extended administration, and prolonged infusion. In addition, select reference citations from publications identified were reviewed. All articles that involved extended-infusion piperacillin-tazobactam implementation strategies were included in the review. Infusion pump characteristics and tubing residuals can affect extended-infusion piperacillin-tazobactam dosing strategies. Two studies addressing tubing residuals were identified. Both studies recommended increasing infusion volumes to compensate for tubing residuals. One study also recommended decreasing infusion-line dead space by using alternative infusion pump systems. Study calculations suggest that higher doses of piperacillin-tazobactam may be used to account for medication left in tubing residuals if alternative infusion pump systems cannot be obtained, and increased infusion volumes are not an option. Extended-infusion piperacillin-tazobactam has been used as a method of maximizing pharmacodynamic target attainment. Use of higher doses of piperacillin-tazobactam may be a reasonable method to compensate for drug loss due to residual volumes in large-bore intravenous pump tubing.

  3. Intraarterial infusion chemotherapy for the treatment of metastatic liver cancer

    International Nuclear Information System (INIS)

    Arai, Yasuaki; Kido, Choichiro

    1987-01-01

    Some techniques of the most recent interventional radiology are very useful for the treatment of metastatic liver cancer and changing the style of hepatic infusion chemotherapy. This report shows our latest results and methods of hepatic infusion chemotherapy for metastatic liver cancer. 1. For the catheter placement, a new catheterization route via the left subclavian artery into the hepatic artery was developed and performed in 132 cases. Superselective catheterization succeeded in 123 cases (93.2 %). This procedure is less invasive than laparotomy and less troublesome than other percutaneous routes. 2. For useful infusion system, an implantable injection port ''Reservoir'' was developed and it was used in 87 cases. This method makes arterial infusion chemotherapy easy, and imploves their quality of life. 3. To acquire adequate drug delivery, arterial redistribution by steel coils was done, and 109 arteries in 80 cases were occluded. This method is very useful to make multiple hepatic artery single and it is important to avoid gasroduodenal complications. 4. Now, using these techniques, the phase II study of 5FU, ADM, MMC combined hepatic infusion in patients with non-resectable metastatic liver cancer is done. Up to this time, such a phase study on arterial infusion chemotherapy was difficult because of technical problems, but these new techniques make it possible. In conclusion, these new methods change the style and conception of hepatic infusion, and these make much progress on the treatment of patients with metastatic liver cancer. (author)

  4. Radiation resistance of microorganisms on unsterilized infusion sets

    DEFF Research Database (Denmark)

    Christensen, E. Ahrensburg; Kristensen, H.; Hoborn, J.

    1991-01-01

    Three different methods were used for detecting and isolating microorganisms with high radiation resistance from the microbial contamination on infusion sets prior to sterilization. By all three methods, microorganisms with a radiation resistance high enough to be a critical factor in a steriliza......Three different methods were used for detecting and isolating microorganisms with high radiation resistance from the microbial contamination on infusion sets prior to sterilization. By all three methods, microorganisms with a radiation resistance high enough to be a critical factor...

  5. [Continuous subcutaneous infusion in palliative care, an undervalued method].

    Science.gov (United States)

    van Marum, R J; de Vogel, E M; Zylicz, Z

    2002-11-23

    Three patients, 2 men aged 55 and 54 years and a woman aged 86 years, were admitted to hospital for treatment of symptoms resulting from terminal disease (pain, agitation, nausea etc.). In all three patients, continuous subcutaneous infusion (CSI) of medication was successfully used to control the symptoms. Compared with intravenous infusion, the technique of CSI is easy to learn and is associated with fewer complications. Its reliability and ease-of-use make it a technique that can be used not only in a hospital setting, but also in general practice and nursing homes. Medication used in palliative care (e.g. morphine, haloperidol, metoclopramide, levomepromazine, midazolam) can often be administered safely by CSI. In palliative care, where goals should be accomplished with minimal burden to the patient, CSI must be considered the technique of choice in patients who are unable to swallow their medication.

  6. Synthesis and assessment methods for an edge-alignment-free hybrid image

    Science.gov (United States)

    Sripian, Peeraya; Yamaguchi, Yasushi

    2017-07-01

    A hybrid image allows multiple image interpretations to be modulated by the viewing distance. It can be constructed on the basis of the multiscale perceptual mechanisms of the human visual system by combining the low and high spatial frequencies of two different images. The hybrid image was introduced as an experimental tool for visual recognition study in terms of spatial frequency perception. To produce a compelling hybrid image, the original hybrid image synthesis method could only use similar shapes of source images that were aligned in the edges. If any two different images can be hybrid, it would be beneficial as a new experimental tool. In addition, there is no measure for the actual perception of spatial frequency, whether a single spatial frequency or both spatial frequencies are perceived from the hybrid stimulus. This paper describes two methods for synthesizing a hybrid image from dissimilar shape images or unaligned images; this hybrid image is known as an "edge-alignment-free hybrid image." A noise-inserted method can be done by intentionally inserting and enhancing noises into the high-frequency image. With this method, the low-frequency blobs are covered with high-frequency noises when viewed up close. A color-inserted method uses complementary color gratings in the background of the high-frequency image to emphasize the high-frequency image when viewed up close, whereas the gratings disappear when viewed from far away. To ascertain that our approach successfully separates the spatial frequency at each viewing distance, we measured this property using our proposed assessment method. Our proposed method allows the experimenter to quantify the probability of perceiving both spatial frequencies and a single spatial frequency in a hybrid image. The experimental results confirmed that our proposed synthesis methods successfully hid the low-frequency image and emphasized the high-frequency image at a close viewing distance. At the same time, the

  7. Methods for studying medical device technology and practitioner cognition : The case of user-interface issues with infusion pumps

    NARCIS (Netherlands)

    Schraagen, J.M.C.; Verhoeven, F.

    2013-01-01

    Purpose : The aims of this study were to investigate how a variety of research methods is commonly employed to study technology and practitioner cognition. User-interface issues with infusion pumps were selected as a case because of its relevance to patient safety. Methods : Starting from a

  8. Hybrid diffusion–transport spatial homogenization method

    International Nuclear Information System (INIS)

    Kooreman, Gabriel; Rahnema, Farzad

    2014-01-01

    Highlights: • A new hybrid diffusion–transport homogenization method. • An extension of the consistent spatial homogenization (CSH) transport method. • Auxiliary cross section makes homogenized diffusion consistent with heterogeneous diffusion. • An on-the-fly re-homogenization in transport. • The method is faster than fine-mesh transport by 6–8 times. - Abstract: A new hybrid diffusion–transport homogenization method has been developed by extending the consistent spatial homogenization (CSH) transport method to include diffusion theory. As in the CSH method, an “auxiliary cross section” term is introduced into the source term, making the resulting homogenized diffusion equation consistent with its heterogeneous counterpart. The method then utilizes an on-the-fly re-homogenization in transport theory at the assembly level in order to correct for core environment effects on the homogenized cross sections and the auxiliary cross section. The method has been derived in general geometry and tested in a 1-D boiling water reactor (BWR) core benchmark problem for both controlled and uncontrolled configurations. The method has been shown to converge to the reference solution with less than 1.7% average flux error in less than one third the computational time as the CSH method – 6 to 8 times faster than fine-mesh transport

  9. Hybrid Method Simulation of Slender Marine Structures

    DEFF Research Database (Denmark)

    Christiansen, Niels Hørbye

    This present thesis consists of an extended summary and five appended papers concerning various aspects of the implementation of a hybrid method which combines classical simulation methods and artificial neural networks. The thesis covers three main topics. Common for all these topics...... only recognize patterns similar to those comprised in the data used to train the network. Fatigue life evaluation of marine structures often considers simulations of more than a hundred different sea states. Hence, in order for this method to be useful, the training data must be arranged so...... that a single neural network can cover all relevant sea states. The applicability and performance of the present hybrid method is demonstrated on a numerical model of a mooring line attached to a floating offshore platform. The second part of the thesis demonstrates how sequential neural networks can be used...

  10. Infusion Antihypoxants in Children with Critical Conditions

    Directory of Open Access Journals (Sweden)

    Yu. S. Aleksandrovich

    2014-01-01

    Full Text Available Hypoxia and mitochondrial damage are a key component of the pathogenesis and tanatogenesis of a critical condition, suggesting the need for its prevention and maximally rapid elimination. Objective: to analyze the efficacy and safety of infusion antihypoxants used in critically ill children from the results of researches. Materials and methods. Available investigations dealing with infusion therapy in children and papers on the use of infusion antihypoxants in adults in 2005 to 2013 were sought in the medical databases PubMed and Cochrane Library with their free availability and analyzed. Results. The analysis included 70 trials. The pathophysiology and pathobiochemistry of hypoxia in critically ill children are given; the current principles of its correction by infusion therapy are considered in detail. Particular emphasis is placed on trials evaluating the efficacy and safety of succinic acid solutions in children. Main indications for and contraindications to their use are demonstrated. Conclusion. The use of Krebs cycle substrate-based infusion antihypoxants (malate, succinate is an effective and promising procedure for the intensive therapy and correction of hypoxia in both adults and children with critical conditions. Considering the fact that papers on the use of infusion antihypoxants in children are scanty, there is a need for further investigations. 

  11. Design of Infusion Schemes for Neuroreceptor Imaging

    DEFF Research Database (Denmark)

    Feng, Ling; Svarer, Claus; Madsen, Karine

    2016-01-01

    for bolus infusion (BI) or programmed infusion (PI) experiments. Steady-state quantitative measurements can be made with one short scan and venous blood samples. The GABAA receptor ligand [(11)C]Flumazenil (FMZ) was chosen for this purpose, as it lacks a suitable reference region. Methods. Five bolus [(11)C...... state was attained within 40 min, which was 8 min earlier than the optimal BI (B/I ratio = 55 min). Conclusions. The system can design both BI and PI schemes to attain steady state rapidly. For example, subjects can be [(11)C]FMZ-PET scanned after 40 min of tracer infusion for 40 min with venous...

  12. Battery control system for hybrid vehicle and method for controlling a hybrid vehicle battery

    Science.gov (United States)

    Bockelmann, Thomas R [Battle Creek, MI; Hope, Mark E [Marshall, MI; Zou, Zhanjiang [Battle Creek, MI; Kang, Xiaosong [Battle Creek, MI

    2009-02-10

    A battery control system for hybrid vehicle includes a hybrid powertrain battery, a vehicle accessory battery, and a prime mover driven generator adapted to charge the vehicle accessory battery. A detecting arrangement is configured to monitor the vehicle accessory battery's state of charge. A controller is configured to activate the prime mover to drive the generator and recharge the vehicle accessory battery in response to the vehicle accessory battery's state of charge falling below a first predetermined level, or transfer electrical power from the hybrid powertrain battery to the vehicle accessory battery in response to the vehicle accessory battery's state of charge falling below a second predetermined level. The invention further includes a method for controlling a hybrid vehicle powertrain system.

  13. Effect of Insulin Infusion on Liver Protein Synthesis during Hemodialysis

    DEFF Research Database (Denmark)

    Reinhard, Mark; Frystyk, Jan; Jespersen, Bente

    2011-01-01

    Background Hemodialysis (HD) is a catabolic procedure that may contribute to the high frequency of protein-energy wasting among patients receiving maintenance HD. The present study investigated the additional effect of glucose and glucose-insulin infusion on liver protein synthesis during HD...... compared with a meal alone. Methods In a randomized cross-over study with three arms, 11 non-diabetic HD patients were assigned to receive a conventional HD session with either: • no treatment (NT) • IV infusion of glucose (G) • IV infusion of glucose-insulin (GI) During infusions blood glucose levels were...... maintained at 8.0-10.0 mmol/L by additional glucose infusion. Glucose and glucose-insulin infusions were commenced 2 h prior to HD and continued throughout the HD session. Fasting blood samples were collected at baseline before infusion and followed by the only meal allowed during the study. Results Blood...

  14. A study on the development of photoelastic experimental hybrid method for colour isochromatics (I)

    International Nuclear Information System (INIS)

    Hawong, Jai Sug; Nam, Jeong Hwan; Kim, Kyo Hyoung; Kwon, O Sung; Kwon, Gun; Park, Sung Han

    2010-01-01

    Isochromatics obtained from photoelastic experiment shows the stress distributions of the full field of a structure under load. Therefore, stress distributions of the structure can be read at a glance through isochromatics. Many experimental data can be obtained from isochromatics which are then used in various photoelastic experimental hybrid methods for stress analysis. Monochromatic light has however, until now been used in the photoelastic experimental hybrid method to produce black and white isochromatics. The use of black and white isochromatics in photoelastic experimental hybrid method for black and white isochromatics requires high fringe orders in order to obtain sufficient experimental data for photoelastic hybrid techniques. Accordingly, this paper develops the photoelastic experimental hybrid method for color isochromatics in which a fringe order of 1 is enough to gather the experimental data of the photoelastic experimental hybrid method. The method was applied to validate stress concentration problems. Experimental results from this study indicated that the photoelastic experimental hybrid method for color isochromatics is more precise than the photoelastic experimental hybrid method for black and white isochromatics. The use of few fringe orders in photoelastic experimental hybrid method for color isochromatics can offer significant advantages in stress analysis of real components using reflective-type photoelastic experimental method

  15. Use of propofol infusion in alcohol withdrawal-induced refractory delirium tremens

    DEFF Research Database (Denmark)

    Lorentzen, Kristian; Lauritsen, Anne Øberg; Bendtsen, Asger Ole

    2014-01-01

    in case reports. We aimed to evaluate the treatment of delirium tremens with propofol infusion for 48 h. MATERIAL AND METHODS: This study was a single-centre retrospective cohort analysis of 15 patient journals covering the period from May 2012 to September 2013. RESULTS: Five women and ten men were...... and mechanically ventilated in the intensive care unit. The mean propofol infusion rate was 4.22 mg/kg/h. Thirteen patients received supplemental infusion of opioids, whereas seven required concomitant vasopressor infusion. Once propofol infusion was discontinued after 48 h, 12 patients had a long awakening...

  16. Hybrid SN Laplace Transform Method For Slab Lattice Calculations

    International Nuclear Information System (INIS)

    Segatto, Cynthia F.; Vilhena, Marco T.; Zani, Jose H.; Barros, Ricardo C.

    2008-01-01

    In typical lattice cells where a highly absorbing, small fuel element is embedded in the moderator, a large weakly absorbing medium, high-order transport methods become unnecessary. In this paper we describe a hybrid discrete ordinates (S N ) method for slab lattice calculations. This hybrid S N method combines the convenience of a low-order S N method in the moderator with a high-order S N method in the fuel. We use special fuel-moderator interface conditions based on an approximate angular flux interpolation analytical method and the Laplace transform (LTS N ) numerical method to calculate the neutron flux distribution and the thermal disadvantage factor. We present numerical results for a range of typical model problems. (authors)

  17. Forearm metabolism during infusion of adrenaline

    DEFF Research Database (Denmark)

    Simonsen, L; Stefl, B; Bülow, J

    2000-01-01

    Human skeletal muscle metabolism is often investigated by measurements of substrate fluxes across the forearm. To evaluate whether the two forearms give the same metabolic information, nine healthy subjects were studied in the fasted state and during infusion of adrenaline. Both arms were...... catheterized in a cubital vein in the retrograde direction. A femoral artery was catheterized for blood sampling, and a femoral vein for infusion of adrenaline. Forearm blood flow was measured by venous occlusion strain-gauge plethysmography. Forearm subcutaneous adipose tissue blood flow was measured...... by the local 133Xe washout method. Metabolic fluxes were calculated as the product of forearm blood flow and a-v differences of metabolite concentrations. After baseline measurements, adrenaline was infused at a rate of 0.3 nmol kg-1 min-1. No difference in the metabolic information obtained in the fasting...

  18. Design Method and Cost-Benefit Analysis of Hybrid Fiber Used in Asphalt Concrete

    Directory of Open Access Journals (Sweden)

    Haiwei Zhang

    2016-01-01

    Full Text Available Fiber, as an additive, can improve the performance of asphalt concrete and be widely studied, but only a few works have been done for hybrid fiber. This paper presents a new and convenient method to design hybrid fiber and verifies hybrid fiber’s superiority in asphalt pavement engineering. Firstly, this paper expounds the design method used as its applied example with the hybrid fiber composed of lignin, polyester, and polypropylene fibers. In this method, a direct shear device (DSD is used to measure the shear damage energy density (SDED of hybrid fiber modified asphalts, and range and variance statistical analysis are applied to determine the composition proportion of hybrid fiber. Then, the engineering property of hybrid fiber reinforced asphalt concrete (AC-13 is investigated. Finally, a cost-benefit model is developed to analyze the advantage of hybrid fiber compared to single fibers. The results show that the design method employed in this paper can offer a beneficial reference. A combination of 1.8% of lignin fiber and 2.4% of polyester fiber plus 3.0% polypropylene fiber presented the best reinforcement of the hybrid fiber. The cost-benefit model verifies that the hybrid fiber can bring about comprehensive pavement performance and good economy.

  19. Combining situated Cognitive Engineering with a novel testing method in a case study comparing two infusion pump interfaces

    NARCIS (Netherlands)

    Schnittker, R.; Schmettow, M.; Verhoeven, F.; Schraagen, J.M.C.

    2016-01-01

    We validated the usability of a new infusion pump interface designed with a situated Cognitive Engineering approach by comparing it to a reference interface using a novel testing method employing repeated measurements and process measures, in addition to traditional outcome measures. The sample

  20. Levels of Antioxidant Activity and Fluoride Content in Coffee Infusions of Arabica, Robusta and Green Coffee Beans in According to their Brewing Methods.

    Science.gov (United States)

    Wolska, J; Janda, Katarzyna; Jakubczyk, K; Szymkowiak, M; Chlubek, D; Gutowska, I

    2017-10-01

    Coffee is a rich source of dietary antioxidants, and this property links with the fact that coffee is one of the world's most popular beverages. Moreover, it is a source of macro- and microelements, including fluoride. The aim of this work was to determine antioxidant activity of coffee beverages and fluoride content depending on different coffee species and conditions of brewing. Three species of coffee, arabica, robusta and green coffee beans obtained from retail stores in Szczecin (Poland) were analyzed. Five different techniques of preparing drink were used: simple infusion, french press, espresso maker, overflow espresso and Turkish coffee. Antioxidant potential of coffee beverages was investigated spectrophotometrically by DPPH method. Fluoride concentrations were measured by potentiometric method with a fluoride ion-selective electrode. Statistical analysis was performed using Stat Soft Statistica 12.5. Antioxidant activity of infusions was high (71.97-83.21% inhibition of DPPH) depending on coffee species and beverage preparing method. It has been shown that the method of brewing arabica coffee and green coffee significantly affects the antioxidant potential of infusions. The fluoride concentration in the coffee infusions changed depending, both, on the species and conditions of brewing, too (0.013-0.502 mg/L). Methods of brewing didn't make a difference to the antioxidant potential of robusta coffee, which had also the lowest level of fluoride among studied species. Except overflow espresso, the fluoride content was the highest in beverages from green coffee. The highest fluoride content was found in Turkish coffee from green coffee beans.

  1. Reduction Methods for Real-time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian

    2016-01-01

    Hybrid testing constitutes a cost-effective experimental full scale testing method. The method was introduced in the 1960's by Japanese researchers, as an alternative to conventional full scale testing and small scale material testing, such as shake table tests. The principle of the method...... is performed on a glass fibre reinforced polymer composite box girder. The test serves as a pilot test for prospective real-time tests on a wind turbine blade. The Taylor basis is implemented in the test, used to perform the numerical simulations. Despite of a number of introduced errors in the real...... is to divide a structure into a physical substructure and a numerical substructure, and couple these in a test. If the test is conducted in real-time it is referred to as real time hybrid testing. The hybrid testing concept has developed significantly since its introduction in the 1960', both with respect...

  2. Probabilistic Analysis Methods for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Brohus, Henrik; Frier, Christian; Heiselberg, Per

    This paper discusses a general approach for the application of probabilistic analysis methods in the design of ventilation systems. The aims and scope of probabilistic versus deterministic methods are addressed with special emphasis on hybrid ventilation systems. A preliminary application...... of stochastic differential equations is presented comprising a general heat balance for an arbitrary number of loads and zones in a building to determine the thermal behaviour under random conditions....

  3. A hybrid measure-correlate-predict method for long-term wind condition assessment

    International Nuclear Information System (INIS)

    Zhang, Jie; Chowdhury, Souma; Messac, Achille; Hodge, Bri-Mathias

    2014-01-01

    Highlights: • A hybrid measure-correlate-predict (MCP) methodology with greater accuracy is developed. • Three sets of performance metrics are proposed to evaluate the hybrid MCP method. • Both wind speed and direction are considered in the hybrid MCP method. • The best combination of MCP algorithms is determined. • The developed hybrid MCP method is uniquely helpful for long-term wind resource assessment. - Abstract: This paper develops a hybrid measure-correlate-predict (MCP) strategy to assess long-term wind resource variations at a farm site. The hybrid MCP method uses recorded data from multiple reference stations to estimate long-term wind conditions at a target wind plant site with greater accuracy than is possible with data from a single reference station. The weight of each reference station in the hybrid strategy is determined by the (i) distance and (ii) elevation differences between the target farm site and each reference station. In this case, the wind data is divided into sectors according to the wind direction, and the MCP strategy is implemented for each wind direction sector separately. The applicability of the proposed hybrid strategy is investigated using five MCP methods: (i) the linear regression; (ii) the variance ratio; (iii) the Weibull scale; (iv) the artificial neural networks; and (v) the support vector regression. To implement the hybrid MCP methodology, we use hourly averaged wind data recorded at five stations in the state of Minnesota between 07-01-1996 and 06-30-2004. Three sets of performance metrics are used to evaluate the hybrid MCP method. The first set of metrics analyze the statistical performance, including the mean wind speed, wind speed variance, root mean square error, and mean absolute error. The second set of metrics evaluate the distribution of long-term wind speed; to this end, the Weibull distribution and the Multivariate and Multimodal Wind Distribution models are adopted. The third set of metrics analyze

  4. System for cooling hybrid vehicle electronics, method for cooling hybrid vehicle electronics

    Science.gov (United States)

    France, David M.; Yu, Wenhua; Singh, Dileep; Zhao, Weihuan

    2017-11-21

    The invention provides a single radiator cooling system for use in hybrid electric vehicles, the system comprising a surface in thermal communication with electronics, and subcooled boiling fluid contacting the surface. The invention also provides a single radiator method for simultaneously cooling electronics and an internal combustion engine in a hybrid electric vehicle, the method comprising separating a coolant fluid into a first portion and a second portion; directing the first portion to the electronics and the second portion to the internal combustion engine for a time sufficient to maintain the temperature of the electronics at or below 175.degree. C.; combining the first and second portion to reestablish the coolant fluid; and treating the reestablished coolant fluid to the single radiator for a time sufficient to decrease the temperature of the reestablished coolant fluid to the temperature it had before separation.

  5. Hybrid RANS-LES using high order numerical methods

    Science.gov (United States)

    Henry de Frahan, Marc; Yellapantula, Shashank; Vijayakumar, Ganesh; Knaus, Robert; Sprague, Michael

    2017-11-01

    Understanding the impact of wind turbine wake dynamics on downstream turbines is particularly important for the design of efficient wind farms. Due to their tractable computational cost, hybrid RANS/LES models are an attractive framework for simulating separation flows such as the wake dynamics behind a wind turbine. High-order numerical methods can be computationally efficient and provide increased accuracy in simulating complex flows. In the context of LES, high-order numerical methods have shown some success in predictions of turbulent flows. However, the specifics of hybrid RANS-LES models, including the transition region between both modeling frameworks, pose unique challenges for high-order numerical methods. In this work, we study the effect of increasing the order of accuracy of the numerical scheme in simulations of canonical turbulent flows using RANS, LES, and hybrid RANS-LES models. We describe the interactions between filtering, model transition, and order of accuracy and their effect on turbulence quantities such as kinetic energy spectra, boundary layer evolution, and dissipation rate. This work was funded by the U.S. Department of Energy, Exascale Computing Project, under Contract No. DE-AC36-08-GO28308 with the National Renewable Energy Laboratory.

  6. Superselective intraarterial infusion therapy for head and neck carcinomas

    International Nuclear Information System (INIS)

    Nakatani, Hiroaki; Sawada, Shoichi; Takeda, Taizo

    2004-01-01

    We report the results of superselective intraarterial cisplatin (CDDP) infusion therapy combined with irradiation for 23 patients, mainly advanced head and neck carcinoma. All patients received intraarterial CDDP infusions with intravenous sodium thiosulfate (STS) neutralization. CDDP infusion was performed by the Seldinger's technique in 16 patients and by the implanted intraarterial reservoir system in 7 patients. STS was also infused by the reservoir system implanted at the forearm in most patients. An overall response was observed in 21 of the 23 (91.3%) patients. Complete and partial responses were achieved in 16 (69.6%) and 5 (21.7%) patients, respectively. There were no patients with worse than grade III complications. We concluded that superselective intraarterial infusion therapy with a high dose of CDDP and STS was very effective for the management of advanced head and neck carcinomas and we recommend the implantable reservoir system for both CDDP and STS administration as an easy and low-invasive method. (author)

  7. Tranexamic Acid in Bolus Alone Vs Bolus and Continuous Infusion in Hip Arthroscopy

    OpenAIRE

    Fatih Karaaslan; Roberto Seijas; Andrea Sallent; Oscar Ares; Wenceslao Espinosa; Pedro Alvarez; Ramón Cugat; Patricia Lopez

    2017-01-01

    AIM: the present study examines the effects of tranexamic acid (TXA) on reducing blood loss during hip arthroscopy, comparing two different methods of administration (bolus vs infusion). METHODS: a prospective study with 70 patients undergoing hip arthroscopy was carried out. The patients within the TXA infusion group (group A) received TXA an 2-g intravenous bolus 30 min before skin incision intravenously followed by 10 mg/kg/h infusion (continued during the entire surgery)...

  8. Hybrid immersed interface-immersed boundary methods for AC dielectrophoresis

    International Nuclear Information System (INIS)

    Hossan, Mohammad Robiul; Dillon, Robert; Dutta, Prashanta

    2014-01-01

    Dielectrophoresis, a nonlinear electrokinetic transport mechanism, has become popular in many engineering applications including manipulation, characterization and actuation of biomaterials, particles and biological cells. In this paper, we present a hybrid immersed interface–immersed boundary method to study AC dielectrophoresis where an algorithm is developed to solve the complex Poisson equation using a real variable formulation. An immersed interface method is employed to obtain the AC electric field in a fluid media with suspended particles and an immersed boundary method is used for the fluid equations and particle transport. The convergence of the proposed algorithm as well as validation of the hybrid scheme with experimental results is presented. In this paper, the Maxwell stress tensor is used to calculate the dielectrophoretic force acting on particles by considering the physical effect of particles in the computational domain. Thus, this study eliminates the approximations used in point dipole methods for calculating dielectrophoretic force. A comparative study between Maxwell stress tensor and point dipole methods for computing dielectrophoretic forces are presented. The hybrid method is used to investigate the physics of dielectrophoresis in microfluidic devices using an AC electric field. The numerical results show that with proper design and appropriate selection of applied potential and frequency, global electric field minima can be obtained to facilitate multiple particle trapping by exploiting the mechanism of negative dielectrophoresis. Our numerical results also show that electrically neutral particles form a chain parallel to the applied electric field irrespective of their initial orientation when an AC electric field is applied. This proposed hybrid numerical scheme will help to better understand dielectrophoresis and to design and optimize microfluidic devices

  9. Continuous-infusion adriamycin

    International Nuclear Information System (INIS)

    Benjamin, R.S.; Chawla, S.P.; Ewer, M.S.; Hortobagyi, G.N.

    1986-01-01

    This chapter discusses the diminished cardiotoxicity as well as diminished nausea and vomiting with continuous infusions of adriamycin to patients undergoing radiation therapy, particularly with infusions of 48 hours or longer, and best with 96-hour infusions, the longest duration that has been studied systematically. In breast cancer, data show that more adriamycin is better, but only for a selected subgroup of patients: those with complete remission. The diminished cardiotoxicity makes the use of adriamycin more attractive in the adjuvant situation, where increased safety will decrease the chances of long-term complications and make retreatment easy for cured patients who develop second malignancies

  10. Infusion of radionuclides throughout pregnancy

    International Nuclear Information System (INIS)

    Mountford-Lister, P.G.; Lambert, B.E.; Milner, A.C.; Kang, X.Z.

    1992-01-01

    This work is part of a long-term study to examine the cancer incidence in the offspring of mice exposed to 239 Pu or 147 Pm throughout pregnancy. The need to model the human intake scenario and the possibility of a critical period during uterine development necessitates constant availability of radionuclides throughout pregnancy. Various methods (multiple daily injections, infusion by external cannula and infusion by indwelling osmotic pump) have been examined and osmotic infusion pumps chosen. These pumps result in a near-constant blood concentration for up to 21 days. Part of the study is the estimation of dose to the critical haemopoietic tissues of the pup from a knowledge of the radionuclide distribution and kinetics. At present the distribution has been followed from birth to 180 days. Activity in the suckling pups at 7 days old is around 1 percent of the infused activity, though most of this is accounted for by the contents of the stomach and gastrointestinal tract. The liver and femur account for around 0.025 percent and 0.012 percent respectively per pup. Activity increases in both liver and femur during lactation after which both concentration and activity fall with time. Long-term studies with the pups of dams exposed to a range of 239 Pu concentrations between 0-70 kBq/kg are underway. Correlation of average organ dose with tumour incidence will be determined at completion of the life-span study. (Author) 39 refs., 5 tabs., 6 figs

  11. Thrombolytic treatment for acute ischemic cerebral stroke: intraarterial urokinase infusion vs. intravenous heparin and urokinase infusion

    International Nuclear Information System (INIS)

    Ko, Gi Young; Suh, Dae Chul; Lee, Jae Hong; Kim, Jun Hyoung; Choi, Choong Gon; Lee, Ho Kyu; Lee, Myoung Chong

    1996-01-01

    To evaluate the efficacy and limitation of intra-arterial urokinase (IAUK) infusion for treatment of acute cerebral stroke. Twenty-seven acute cerebral stroke patients treated with IAUK infusion within six hours of stroke onset were reviewed. All patients showed normal initial brain findings on CT. In 21 patients, urokinase(5-15 x 10 5 IU) was administered through a microcatheter placed into or proximal to occluded segment. Mechanical disruption of thrombus by guidewire was performed in 17 patients. Angiographic and clinical responses and complications after IAUK infusion, were evaluated and the results were compared with those of intravenous heparin(N=19) and urokinase infusion(N=19). Complete or partial angiographic recanalization of occluded segment was found in 18 patients (67%), and neurologic improvement was followed in 14 patients(52%). The degree of improvement on the stroke scale score after IAUK infusion was statistically more significant(p<0.05) than that shown after intravenous heparin and urokinase infusion. Complications after IAUK infusion were large(15%) and small amount intracerebral hemorrhage(15%), contrast leakage into brain parenchyma(11%), and gastrointestinal bleeding(4%). Between the IAVK and the intravenous urokinase infusion group, differences in extent and types of complications were statistically insignificant, but were significantly higher in those two groups than in the intravenous heparin infusion group. IAUK infusion may be effective for the treatment of acute cerebral stroke

  12. Subcutaneous insulin infusion: change in basal infusion rate has no immediate effect on insulin absorption rate

    International Nuclear Information System (INIS)

    Hildebrandt, P.; Birch, K.; Jensen, B.M.; Kuehl, C.

    1986-01-01

    Eight insulin-dependent diabetic patients were simultaneously given subcutaneous infusions (1.12 IU/h each) of 125 I-labeled Actrapid insulin in each side of the abdominal wall. After 24 h of infusion, the size of the infused insulin depots was measured by external counting for 5 h. The basal infusion rate was then doubled in one side and halved in the other for the next 4 h. Finally, 1.12 IU/h of insulin was given in both sides of the abdominal wall for an additional 3 h. The changes in the size of the depots were measured, and the absorption rates for each hour were calculated. During the first 5 h of infusion, the depot size was almost constant (approximately 5 IU) with an absorption rate that equaled the infusion rate. Doubling the infusion rate led to a significant increase in depot size, but the absorption rate remained unchanged for the first 3 h, and only thereafter was a significant increase seen. When the infusion rate was reduced to the initial 1.12 IU/h, the absorption rate remained elevated during the next 3 h. Correspondingly, when the infusion rate was decreased, the depot size also decreased, but the absorption rate remained unchanged for the first 3 h. The results show that a change in the basal insulin infusion rate does not lead to any immediate change in the insulin absorption rate. This should be considered when planning an insulin-infusion program that includes alteration(s) in the basal-rate setting

  13. Solution of the radiative enclosure with a hybrid inverse method

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rogerio Brittes da; Franca, Francis Henrique Ramos [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Dept. de Engenharia Mecanica], E-mail: frfranca@mecanica.ufrgs.br

    2010-07-01

    This work applies the inverse analysis to solve a three-dimensional radiative enclosure - which the surfaces are diffuse-grays - filled with transparent medium. The aim is determine the powers and locations of the heaters to attain both uniform heat flux and temperature on the design surface. A hybrid solution that couples two methods, the generalized extremal optimization (GEO) and the truncated singular value decomposition (TSVD) is proposed. The determination of the heat sources distribution is treated as an optimization problem, by GEO algorithm , whereas the solution of the system of equation, that embodies the Fredholm equation of first kind and therefore is expected to be ill conditioned, is build up through TSVD regularization method. The results show that the hybrid method can lead to a heat flux on the design surface that satisfies the imposed conditions with maximum error of less than 1,10%. The results illustrated the relevance of a hybrid method as a prediction tool. (author)

  14. Antioxidant and Acetylcholinesterase Inhibiting Activity of Several Aqueous Tea Infusions in vitro

    Directory of Open Access Journals (Sweden)

    Višnja Katalinić

    2008-01-01

    Full Text Available A study of antioxidant activity and acetylcholineste ase (AChE inhibitory activity of aqueous tea infusions prepared from walnut (Juglans regia L., peppermint (Mentha×piperita L., strawberry (Fragaria×ananassa L., lemon balm (Melissa officinalis L., sage (Salvia officinalis L., and immortelle (Helichrysum arenarium (L. Moench. is presented here. Chemical composition of selected aqueous tea infusions was determined by high-performance liquid chromatography with photodiode-array method (HPLC-PDA, and the following phenolic compounds were identified as dominant: rosmarinic acid, gallic acid (not identified in walnut and sage, caffeic acid (in sage and peppermint, neochlorogenic acid, 3-p-coumaroylquinic acid and quercetin 3-galactoside (in walnut and luteolin 7-O-glucoside (in sage. Antioxidant activity of the selected aqueous tea infusions was measured using low-density lipoprotein (LDL oxidation method, 2,2'-diphenyl-1-picrylhydrazyl (DPPH radical scavenging test, β-carotene bleaching method, and Rancimat method (induction period of lard oxidation. Strawberry and lemon balm aqueous infusions completely inhibited LDL oxidation at the concentration of 0.005 g/L in the reacting system. Very long prolongation of the lag phase was achieved with peppermint and sage aqueous infusions. All tested infusions in the concentration range of 0.05–2.85 g/L showed very pronounced effect of DPPH scavenging activity (90–100 % as well as the inhibition of β-carotene bleaching (89–100 %. In pure lipid medium, used in Rancimat method, sage and immortelle at the concentration of 0.16 % (by mass had the highest ability to inhibit lipid peroxidation process. Screening of the AChE inhibitory activity by Ellman´s method showed that the strongest inhibition was obtained with walnut and strawberry aqueous infusions at the concentration of 1.36 g/L in the reacting system. The presented results suggest that natural antioxidants could be useful and merit further

  15. Does prolonged β-lactam infusions improve clinical outcomes compared to intermittent infusions? A meta-analysis and systematic review of randomized, controlled trials

    Directory of Open Access Journals (Sweden)

    Van Arendonk Kyle J

    2011-06-01

    Full Text Available Abstract Background The emergence of multi-drug resistant Gram-negatives (MDRGNs coupled with an alarming scarcity of new antibiotics has forced the optimization of the therapeutic potential of available antibiotics. To exploit the time above the minimum inhibitory concentration mechanism of β-lactams, prolonging their infusion may improve outcomes. The primary objective of this meta-analysis was to determine if prolonged β-lactam infusion resulted in decreased mortality and improved clinical cure compared to intermittent β-lactam infusion. Methods Relevant studies were identified from searches of MEDLINE, EMBASE, and CENTRAL. Heterogeneity was assessed qualitatively, in addition to I2 and Chi-square statistics. Pooled relative risks (RR and 95% confidence intervals (CI were calculated using Mantel-Haenszel random-effects models. Results Fourteen randomized controlled trials (RCTs were included. Prolonged infusion β-lactams were not associated with decreased mortality (n= 982; RR 0.92; 95% CI:0.61-1.37 or clinical cure (n = 1380; RR 1.00 95% CI:0.94-1.06 compared to intermittent infusions. Subgroup analysis for β-lactam subclasses and equivalent total daily β-lactam doses yielded similar results. Most studies had notable methodological flaws. Conclusions No clinical advantage was observed for prolonged infusion β-lactams. The limited number of studies with MDRGNs precluded evaluation of prolonged infusion of β-lactams for this subgroup. A large, multicenter RCT with critically ill patients infected with MDRGNs is needed.

  16. Natriuretic peptide infusion reduces myocardial injury during acute ischemia/reperfusion

    DEFF Research Database (Denmark)

    Kousholt, Birgitte S.; Larsen, Jens Kjærgaard Rolighed; Bisgaard, Line Stattau

    2012-01-01

    Aim: The aim of this study was to determine whether a natriuretic peptide infusion during reperfusion can reduce cardiomyocyte ischemia–reperfusion damage. Materials and methods: The effect of B-type natriuretic peptide (BNP) activity was assessed in vitro and in vivo: the cellular effect...... in apoptotic changes in the BNP-stimulated cells. Pigs tolerated the BNP and CD-NP (a CNP analogue) infusion well, with a decrease in systemic blood pressure (~15 mmHg) and increased diuresis compared with the controls. Left ventricular pressure decreased in the pigs that received BNP infusion compared...... with controls (P=0.02). A similar trend was observed in the pigs that received CD-NP infusion, although this was not significant (P=0.3). BNP and CD-NP infusion in pigs reduced total cardiac troponin T release by 46 and 40%, respectively (P=0.0015 and 0.0019), and were associated with improved RNA integrity...

  17. Natriuretic peptide infusion reduces myocardial injury during acute ischemia/reperfusion

    DEFF Research Database (Denmark)

    Kousholt, Birgitte S.; Larsen, Jens Kjærgaard Rolighed; Bisgaard, Line Stattau

    2012-01-01

    Aim: The aim of this study was to determine whether a natriuretic peptide infusion during reperfusion can reduce cardiomyocyte ischemia–reperfusion damage. Materials and methods: The effect of B-type natriuretic peptide (BNP) activity was assessed in vitro and in vivo: the cellular effect...... in apoptotic changes in the BNP-stimulated cells. Pigs tolerated the BNP and CD-NP (a CNP analogue) infusion well, with a decrease in systemic blood pressure (∼15 mmHg) and increased diuresis compared with the controls. Left ventricular pressure decreased in the pigs that received BNP infusion compared...... with controls (P=0.02). A similar trend was observed in the pigs that received CD-NP infusion, although this was not significant (P=0.3). BNP and CD-NP infusion in pigs reduced total cardiac troponin T release by 46 and 40%, respectively (P=0.0015 and 0.0019), and were associated with improved RNA integrity...

  18. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  19. Hybrid Prediction Method for Aircraft Interior Noise, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the project is research and development of methods for application of the Hybrid FE-SEA method to aircraft vibro-acoustic problems. This proposal...

  20. A modeling method for hybrid energy behaviors in flexible machining systems

    International Nuclear Information System (INIS)

    Li, Yufeng; He, Yan; Wang, Yan; Wang, Yulin; Yan, Ping; Lin, Shenlong

    2015-01-01

    Increasingly environmental and economic pressures have led to great concerns regarding the energy consumption of machining systems. Understanding energy behaviors of flexible machining systems is a prerequisite for improving energy efficiency of these systems. This paper proposes a modeling method to predict energy behaviors in flexible machining systems. The hybrid energy behaviors not only depend on the technical specification related of machine tools and workpieces, but are significantly affected by individual production scenarios. In the method, hybrid energy behaviors are decomposed into Structure-related energy behaviors, State-related energy behaviors, Process-related energy behaviors and Assignment-related energy behaviors. The modeling method for the hybrid energy behaviors is proposed based on Colored Timed Object-oriented Petri Net (CTOPN). The former two types of energy behaviors are modeled by constructing the structure of CTOPN, whist the latter two types of behaviors are simulated by applying colored tokens and associated attributes. Machining on two workpieces in the experimental workshop were undertaken to verify the proposed modeling method. The results showed that the method can provide multi-perspective transparency on energy consumption related to machine tools, workpieces as well as production management, and is particularly suitable for flexible manufacturing system when frequent changes in machining systems are often encountered. - Highlights: • Energy behaviors in flexible machining systems are modeled in this paper. • Hybrid characteristics of energy behaviors are examined from multiple viewpoints. • Flexible modeling method CTOPN is used to predict the hybrid energy behaviors. • This work offers a multi-perspective transparency on energy consumption

  1. Brain SPECT by intraarterial infusion of 99mTc-HMPAO for assessing the cerebral distribution of carotid artery infusions in patient with brain tumor

    International Nuclear Information System (INIS)

    Kosuda, Shigeru; Kusano, Shoichi; Aoki, Shigeki

    1993-01-01

    In order to assess the cerebral distribution of intracarotid chemotherapy, 17 postoperative patients with brain tumor underwent brain SPECT obtrained by intraarterial infusion of 18.5 MBq of 99m Tc-d,l,-hexamethylpropyleneamine oxime ( 99m Tc-HMPAO). Injection methods were continuous (5.0 ml/min) or pulsatile infusion with supra- or infraophthalmic catheterization. The findings obtained by brain SPECT were frequently different from those of angiography and/or DSA. In supraophthalmic catheterization with continuous infusion, only 2 of 10 studies (20%) had homogeneous distribution and 5 of them (50%) had maldistribution of 99m Tc-HMPAO which appears in association with laminar flow effect. The remaining 3 studies showed localized distribution (two: tumor localization, one: healthy brain localization). On the other hand, all of 5 studies with pulsatile infusion had homogeneous distribution of 99m Tc-HMPAO. In infraophthalmic catheterization, all but one of 5 studies had homogeneous distribution with continuous infusion. These results suggest that pulsatile infusion may be effective in eliminating maldistribution of 99m Tc-HMPAO in supraophthalmic catheterization. In conclusion, we are convinced that 99m Tc-HMPAO is a useful intraarterial agent for assessing cerebral distribution of intracarotid chemotherpay. (author)

  2. Hybrid numerical calculation method for bend waveguides

    OpenAIRE

    Garnier , Lucas; Saavedra , C.; Castro-Beltran , Rigoberto; Lucio , José Luis; Bêche , Bruno

    2017-01-01

    National audience; The knowledge of how the light will behave in a waveguide with a radius of curvature becomes more and more important because of the development of integrated photonics, which include ring micro-resonators, phasars, and other devices with a radius of curvature. This work presents a numerical calculation method to determine the eigenvalues and eigenvectors of curved waveguides. This method is a hybrid method which uses at first conform transformation of the complex plane gene...

  3. Infusion pressure and pain during microneedle injection into skin of human subjects

    Science.gov (United States)

    Gupta, Jyoti; Park, Sohyun; Bondy, Brian; Felner, Eric I.; Prausnitz, Mark R.

    2011-01-01

    Infusion into skin using hollow microneedles offers an attractive alternative to hypodermic needle injections. However, the fluid mechanics and pain associated with injection into skin using a microneedle have not been studied in detail before. Here, we report on the effect of microneedle insertion depth into skin, partial needle retraction, fluid infusion flow rate and the co-administration of hyaluronidase on infusion pressure during microneedle-based saline infusion, as well as on associated pain in human subjects. Infusion of up to a few hundred microliters of fluid required pressures of a few hundred mmHg, caused little to no pain, and showed weak dependence on infusion parameters. Infusion of larger volumes up to 1 mL required pressures up to a few thousand mmHg, but still usually caused little pain. In general, injection of larger volumes of fluid required larger pressures and application of larger pressures cause more pain, although other experimental parameters also played a significant role. Among the intradermal microneedle groups, microneedle length had little effect; microneedle retraction lowered infusion pressure but increased pain; lower flow rate reduced infusion pressure and kept pain low; and use of hyaluronidase also lowered infusion pressure and kept pain low. We conclude that microneedles offer a simple method to infuse fluid into the skin that can be carried out with little to no pain. PMID:21684001

  4. Safe and tolerable one-hour pamidronate infusion for multiple myeloma patients

    Directory of Open Access Journals (Sweden)

    Dimitrios Chantzichristos

    2008-09-01

    Full Text Available Dimitrios Chantzichristos, Andréasson Björn, Johansson PeterDepartment of Internal Medicine, Uddevalla Hospital, Uddevalla, SwedenBackground: Once a month, patients with multiple myeloma received an infusion of bisphosphonates, principally to reduce osteoclastic bone resorption. Recommended infusion time for pamidronate is 2 hours in the US and 4 hours in Europe because of its potential nephrotoxicity. From 2003, a 90 mg infusion of pamidronate was provided over 1 hour to patients with no pre-existing renal impairment, in the Daily Care Unit at Uddevalla Hospital.Method: Retrospective analysis of the renal deterioration, serum calcium, and adverse effects in patients with multiple myeloma treated with 1-hour pamidronate 90 mg infusion from January 2003 to April 2007.Results: Seventy-nine patients provided valuable data. A total number of 846 infusions were given and the median number of infusion to each patient was 11. Significant creatinine elevation was seen in 7 patients (8.9%, after 19 infusions (2.2%. Renal deterioration occurred in 5 of these 7 patients, which was related to progress of the myeloma or opportunistic infections. Prevalence of infusion-related events was 0.8% and the mean total S-Ca was 0.05 mmol/L lower than the baseline.Conclusion: Few events of renal deterioration, hypocalcemia, or other adverse effects resulted from a 1-hour pamidronate 90 mg infusion for multiple myeloma patients with no pre-existing renal impairment.Keywords: bisphosphonates, pamidronate, multiple myeloma, infusion time

  5. Hybrid variational principles and synthesis method for finite element neutron transport calculations

    International Nuclear Information System (INIS)

    Ackroyd, R.T.; Nanneh, M.M.

    1990-01-01

    A family of hybrid variational principles is derived using a generalised least squares method. Neutron conservation is automatically satisfied for the hybrid principles employing two trial functions. No interfaces or reflection conditions need to be imposed on the independent even-parity trial function. For some hybrid principles a single trial function can be employed by relating one parity trial function to the other, using one of the parity transport equation in relaxed form. For other hybrid principles the trial functions can be employed sequentially. Synthesis of transport solutions, starting with the diffusion theory approximation, has been used as a way of reducing the scale of the computation that arises with established finite element methods for neutron transport. (author)

  6. A direct hybrid SN method for slab-geometry lattice calculations

    International Nuclear Information System (INIS)

    Silva, Davi J.M.; Barros, Ricardo C.; Zani, Jose H.

    2011-01-01

    In this work we describe a hybrid direct method for calculating the thermal disadvantage factor and the neutron flux distribution in fuel-moderator lattices. For the mathematical model, we use the one-speed slab-geometry discrete ordinates (S N ) transport equation with linearly anisotropic scattering. The basic idea is to use higher order angular quadrature set in the highly absorbing fuel region (S NF ) and lower order angular quadrature set in the diffusive moderator region (S NM ) , i.e., N F > N M . We apply special continuity conditions based on the equivalence of the S N and P N-1 equations, which characterize the hybrid model. Numerical results to a typical model problem are given to illustrate the accuracy and the efficiency of the offered hybrid method. (author)

  7. A hybrid method for evaluating enterprise architecture implementation.

    Science.gov (United States)

    Nikpay, Fatemeh; Ahmad, Rodina; Yin Kia, Chiam

    2017-02-01

    Enterprise Architecture (EA) implementation evaluation provides a set of methods and practices for evaluating the EA implementation artefacts within an EA implementation project. There are insufficient practices in existing EA evaluation models in terms of considering all EA functions and processes, using structured methods in developing EA implementation, employing matured practices, and using appropriate metrics to achieve proper evaluation. The aim of this research is to develop a hybrid evaluation method that supports achieving the objectives of EA implementation. To attain this aim, the first step is to identify EA implementation evaluation practices. To this end, a Systematic Literature Review (SLR) was conducted. Second, the proposed hybrid method was developed based on the foundation and information extracted from the SLR, semi-structured interviews with EA practitioners, program theory evaluation and Information Systems (ISs) evaluation. Finally, the proposed method was validated by means of a case study and expert reviews. This research provides a suitable foundation for researchers who wish to extend and continue this research topic with further analysis and exploration, and for practitioners who would like to employ an effective and lightweight evaluation method for EA projects. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Delivery interaction between co-infused medications: an in vitro modeling study of microinfusion.

    Science.gov (United States)

    Tsao, Amy C; Lovich, Mark A; Parker, Michael J; Zheng, Hui; Peterfreund, Robert A

    2013-01-01

    To test the hypothesis that steady-state drug delivery by continuous infusion is predictably affected by a second drug infusion in the same lumen. Clinicians commonly administer two drugs by continuous infusion through one central venous catheter lumen (co-infusion). To limit fluid delivery, low flow rate carriers transport concentrated drug solutions; a method called microinfusion. How microinfusion delivery of one drug is affected by a second drug infusion has not been explored. Two water-soluble dyes, tartrazine and erioglaucine, infused at 3 ml · h(-1), modeled drug delivery through a four stopcock linear manifold and catheter lumen. A pump drove a carrier fluid (10 ml · h(-1)). After tartrazine reached steady-state delivery, erioglaucine entered downstream or upstream of the tartrazine infusion. Quantitative spectrophotometry measured dye delivery. Starting erioglaucine's infusion upstream of tartrazine's entry caused a transient tartrazine bolus (duration 10 min, peak drug delivery 20% higher than target levels). Starting erioglaucine's infusion downstream produced a similar amplitude, briefer, bolus. Stopping the erioglaucine infusion caused a transient reduction in tartrazine delivery. Measured delivery profiles were comparable to prediction models. We confirmed the hypothesis that delivery of one infused drug is transiently affected by starting or stopping a second drug infusion in the same line. The magnitude of the changes can be estimated quantitatively. The clinical impact depends on the drugs being co-infused and patient sensitivity, but could be clinically important; the findings have safety implications for infused medication delivery to critically ill or anesthetized children. We recommend minimizing infusion system dead volumes, connecting the most essential infusion(s) to the main fluid pathway as close as possible to the patient, and recognizing the potential for unintended alterations in delivery when multiple drugs co-infuse. © 2012

  9. Effect of mesh-peel ply variation on mechanical properties of E-glas composite by infusion vacuum method

    Science.gov (United States)

    Abdurohman, K.; Siahaan, Mabe

    2018-04-01

    Composite materials made of glass fiber EW-135 with epoxy lycal resin with vacuum infusion method have been performed. The dried glass fiber is arranged in a mold then connected to a vacuum machine and a resin tube. Then, the vacuum machine is turned on and at the same time the resin is sucked and flowed into the mold. This paper reports on the effect of using mesh- peel ply singles on upper-side laminates called A and the effect of using double mesh-peel ply on upper and lower-side laminates call B with glass fiber arrangement is normal and ± 450 in vacuum infusion process. Followed by the manufacture of tensile test specimen and tested its tensile strength with universal test machine 100kN Tensilon RTF 2410, at room temperature with constant crosshead speed. From tensile test results using single and double layers showed that double mesh-peel ply can increase tensile strength 14% and Young modulus 17%.

  10. PERAMALAN PERSEDIAAN INFUS MENGGUNAKAN METODE AUTOREGRESSIVE INTEGRATED MOVING AVERAGE (ARIMA) PADA RUMAH SAKIT UMUM PUSAT SANGLAH

    OpenAIRE

    I PUTU YUDI PRABHADIKA; NI KETUT TARI TASTRAWATI; LUH PUTU IDA HARINI

    2018-01-01

    Infusion supplies are an important thing that must be considered by the hospital in meeting the needs of patients. This study aims to predict the need for infusion of 0.9% 500 ml of NaCl and 5% 500 ml glucose infusion at Sanglah General Hospital (RSUP) Sanglah so that the hospital can estimate the many infusions needed for the next six months. The forecasting method used in this research is the autoregressive integrated moving average (ARIMA) time series method. The results of this study indi...

  11. Hybrid statistics-simulations based method for atom-counting from ADF STEM images

    Energy Technology Data Exchange (ETDEWEB)

    De wael, Annelies, E-mail: annelies.dewael@uantwerpen.be [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); De Backer, Annick [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium); Jones, Lewys; Nellist, Peter D. [Department of Materials, University of Oxford, Parks Road, OX1 3PH Oxford (United Kingdom); Van Aert, Sandra, E-mail: sandra.vanaert@uantwerpen.be [Electron Microscopy for Materials Science (EMAT), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp (Belgium)

    2017-06-15

    A hybrid statistics-simulations based method for atom-counting from annular dark field scanning transmission electron microscopy (ADF STEM) images of monotype crystalline nanostructures is presented. Different atom-counting methods already exist for model-like systems. However, the increasing relevance of radiation damage in the study of nanostructures demands a method that allows atom-counting from low dose images with a low signal-to-noise ratio. Therefore, the hybrid method directly includes prior knowledge from image simulations into the existing statistics-based method for atom-counting, and accounts in this manner for possible discrepancies between actual and simulated experimental conditions. It is shown by means of simulations and experiments that this hybrid method outperforms the statistics-based method, especially for low electron doses and small nanoparticles. The analysis of a simulated low dose image of a small nanoparticle suggests that this method allows for far more reliable quantitative analysis of beam-sensitive materials. - Highlights: • A hybrid method for atom-counting from ADF STEM images is introduced. • Image simulations are incorporated into a statistical framework in a reliable manner. • Limits of the existing methods for atom-counting are far exceeded. • Reliable counting results from an experimental low dose image are obtained. • Progress towards reliable quantitative analysis of beam-sensitive materials is made.

  12. Errors and discrepancies in the administration of intravenous infusions: a mixed methods multihospital observational study

    OpenAIRE

    Lyons, I.; Furniss, D.; Blandford, A.; Chumbley, G.; Iacovides, I.; Wei, L.; Cox, A.; Mayer, A.; Vos, J.; Galal-Edeen, G. H.; Schnock, K. O.; Dykes, P. C.; Bates, D. W.; Franklin, B. D.

    2018-01-01

    INTRODUCTION: Intravenous medication administration has traditionally been regarded as error prone, with high potential for harm. A recent US multisite study revealed few potentially harmful errors despite a high overall error rate. However, there is limited evidence about infusion practices in England and how they relate to prevalence and types of error. OBJECTIVES: To determine the prevalence, types and severity of errors and discrepancies in infusion administration in English hospitals, an...

  13. Hippocampal infusions of glucose reverse memory deficits produced by co-infusions of a GABA receptor agonist.

    Science.gov (United States)

    Krebs-Kraft, Desiree L; Parent, Marise B

    2008-02-01

    Although septal infusions of glucose typically have positive effects on memory, we have shown repeatedly that this treatment exacerbates memory deficits produced by co-infusions of gamma-aminobutyric acid (GABA) receptor agonists. The present experiments tested whether this negative interaction between glucose and GABA in the medial septum would be observed in the hippocampus, a brain region where glucose typically has positive effects on memory. Specifically, we determined whether hippocampal infusions of glucose would reverse or exacerbate memory deficits produced by hippocampal co-infusions of the GABA receptor agonist muscimol. Fifteen minutes prior to either assessing spontaneous alternation (SA) or continuous multiple trial inhibitory avoidance (CMIA) training, male Sprague-Dawley-derived rats were given bilateral hippocampal infusions of vehicle (phosphate-buffered saline [PBS], 1 microl/2 min), glucose (33 or 50 nmol), muscimol (0.3 or 0.4 microg, SA or 3 microg, CMIA) or muscimol and glucose combined in one solution. The results indicated that hippocampal infusions of muscimol alone decreased SA scores and CMIA retention latencies. More importantly, hippocampal infusions of glucose, at doses that had no effect when infused alone, attenuated (33 nmol) or reversed (50 nmol) the muscimol-induced memory deficits. Thus, although co-infusions of glucose with muscimol into the medial septum impair memory, the present findings show that an opposite effect is observed in the hippocampus. Collectively, these findings suggest that the memory-impairing interaction between glucose and GABA in the medial septum is not a general property of the brain, but rather is brain region-dependent.

  14. Subcutaneous infusion in palliative care: a focus on the neria soft 90 infusion set.

    Science.gov (United States)

    Gabriel, Janice

    2014-11-01

    Subcutaneous administration of medications and/or fluids can play a crucial part in supporting patients at home and thereby avoiding the need for hospitalisation. It is an area of patient care that has received little attention compared with other types of parenteral therapies. However, it is an effective and safe route for continuous administration for individuals requiring palliative care. Technological advancements have led to improved subcutaneous infusion devices, such as fine-gauge cannulae with integral sharps protection, as well as integral hypoallergenic dressings. These design features not only help to increase patient comfort but also minimise the potential for needlestick injuries, as well as providing the health professional with one sterile package containing all of the components needed to establish subcutaneous infusion. However, technological developments alone are insufficient to improve patient outcomes. Knowledge of the individual patient, together with their diagnosis and intended treatment, will influence the choice of subcutaneous infusion device, with the overall aim of minimising the potential for complications and improving comfort. This paper provides an overview of subcutaneous infusion, including the importance of patient assessment and the education and training needs of health professionals, and then focuses on one specific subcutaneous infusion device: the neria soft 90 infusion set.

  15. Hybrid statistics-simulations based method for atom-counting from ADF STEM images.

    Science.gov (United States)

    De Wael, Annelies; De Backer, Annick; Jones, Lewys; Nellist, Peter D; Van Aert, Sandra

    2017-06-01

    A hybrid statistics-simulations based method for atom-counting from annular dark field scanning transmission electron microscopy (ADF STEM) images of monotype crystalline nanostructures is presented. Different atom-counting methods already exist for model-like systems. However, the increasing relevance of radiation damage in the study of nanostructures demands a method that allows atom-counting from low dose images with a low signal-to-noise ratio. Therefore, the hybrid method directly includes prior knowledge from image simulations into the existing statistics-based method for atom-counting, and accounts in this manner for possible discrepancies between actual and simulated experimental conditions. It is shown by means of simulations and experiments that this hybrid method outperforms the statistics-based method, especially for low electron doses and small nanoparticles. The analysis of a simulated low dose image of a small nanoparticle suggests that this method allows for far more reliable quantitative analysis of beam-sensitive materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Incidence and severity of phlebitis in patients receiving peripherally infused amiodarone.

    Science.gov (United States)

    Boyce, Brenda A Brady; Yee, Barbara Homer

    2012-08-01

    Nurses noted that the rate of phlebitis was high when intravenous amiodarone was infused via a peripheral site. Hospital policy recommends a central vascular catheter, but this method is often not feasible because the drug is administered in emergent situations for short periods. To determine the rate and severity of phlebitis in patients given peripherally infused amiodarone. The literature, policy, and procedures for administration of amiodarone were reviewed; the pharmacy was consulted; and a data collection tool was developed. The tool was pilot tested and revised, and face validation was established. Data were collected during a 6-month period. A convenience sample was used. The study included a total of 12 patients. Each new infusion of intravenous amiodarone was considered a separate occurrence, for a total of 24 infusions. Various grades of phlebitis developed in 8 patients (67%). Phlebitis developed at 12 of the 24 infusion sites (50%). Patients receiving peripherally infused amiodarone are at high risk for phlebitis. This complication may lead to infection, additional medical intervention, delay in treatment, and prolonged hospitalization.

  17. A hybrid numerical method for orbit correction

    International Nuclear Information System (INIS)

    White, G.; Himel, T.; Shoaee, H.

    1997-09-01

    The authors describe a simple hybrid numerical method for beam orbit correction in particle accelerators. The method overcomes both degeneracy in the linear system being solved and respects boundaries on the solution. It uses the Singular Value Decomposition (SVD) to find and remove the null-space in the system, followed by a bounded Linear Least Squares analysis of the remaining recast problem. It was developed for correcting orbit and dispersion in the B-factory rings

  18. Insulin compatibility with polymer materials used in external pump infusion systems.

    Science.gov (United States)

    Melberg, S G; Havelund, S; Villumsen, J; Brange, J

    1988-04-01

    In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.

  19. A general method for identifying major hybrid male sterility genes in Drosophila.

    Science.gov (United States)

    Zeng, L W; Singh, R S

    1995-10-01

    The genes responsible for hybrid male sterility in species crosses are usually identified by introgressing chromosome segments, monitored by visible markers, between closely related species by continuous backcrosses. This commonly used method, however, suffers from two problems. First, it relies on the availability of markers to monitor the introgressed regions and so the portion of the genome examined is limited to the marked regions. Secondly, the introgressed regions are usually large and it is impossible to tell if the effects of the introgressed regions are the result of single (or few) major genes or many minor genes (polygenes). Here we introduce a simple and general method for identifying putative major hybrid male sterility genes which is free of these problems. In this method, the actual hybrid male sterility genes (rather than markers), or tightly linked gene complexes with large effects, are selectively introgressed from one species into the background of another species by repeated backcrosses. This is performed by selectively backcrossing heterozygous (for hybrid male sterility gene or genes) females producing fertile and sterile sons in roughly equal proportions to males of either parental species. As no marker gene is required for this procedure, this method can be used with any species pairs that produce unisexual sterility. With the application of this method, a small X chromosome region of Drosophila mauritiana which produces complete hybrid male sterility (aspermic testes) in the background of D. simulans was identified. Recombination analysis reveals that this region contains a second major hybrid male sterility gene linked to the forked locus located at either 62.7 +/- 0.66 map units or at the centromere region of the X chromosome of D. mauritiana.

  20. A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals

    Directory of Open Access Journals (Sweden)

    Suyi Li

    2017-01-01

    Full Text Available The noninvasive peripheral oxygen saturation (SpO2 and the pulse rate can be extracted from photoplethysmography (PPG signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects’ PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO2 and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis.

  1. A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals.

    Science.gov (United States)

    Li, Suyi; Jiang, Shanqing; Jiang, Shan; Wu, Jiang; Xiong, Wenji; Diao, Shu

    2017-01-01

    The noninvasive peripheral oxygen saturation (SpO 2 ) and the pulse rate can be extracted from photoplethysmography (PPG) signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects' PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO 2 and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis.

  2. A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals

    Science.gov (United States)

    Jiang, Shanqing; Jiang, Shan; Wu, Jiang; Xiong, Wenji

    2017-01-01

    The noninvasive peripheral oxygen saturation (SpO2) and the pulse rate can be extracted from photoplethysmography (PPG) signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects' PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO2 and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis. PMID:29250135

  3. Local Intraarterial Thrombolysis: In Vitro Comparison Between Automatic and Manual Pulse-Spray Infusion

    International Nuclear Information System (INIS)

    Froelich, Jens J.; Freymann, Christina; Hoppe, Martin; Thiel, Thomas; Wagner, H. Joachim; Barth, Klemens H.; Klose, Klaus J.

    1996-01-01

    Purpose: Manual and automatic pulse-spray infusion techniques are compared in vitro to evaluate the efficacy of thrombolysis and the distribution of urokinase and saline solution within thrombus using a pulse-spray catheter. Methods: A pulse-spray catheter was introduced into a human thrombus within a stenotic flow model. Automatic and manual pulsed infusion of urokinase and automatic pulsed infusion of saline solution were compared. To quantify the efficacy of thrombolysis, pressure gradients were recorded proximal and distal to the thrombus and during the course of infusion. Distribution of infused urokinase was assessed radiographically. Results: The fastest and most homogeneous dissolution of the thrombus was achieved with automatic pulsed infusion of urokinase, shown by decreasing transthrombotic pressure gradients (p < 0.001, Wilcoxon, matched pairs). Manual pulsed infusion of urokinase or saline solution resulted in inhomogeneous thrombus dissolution and delayed thrombolysis. Conclusion: Application of automatic pulse-spray injectors seems beneficial for more effective and homogeneous intraarterial pulse-spray thrombolysis when compared with conventional manual pulsed technique

  4. An efficient method for hybrid density functional calculation with spin-orbit coupling

    Science.gov (United States)

    Wang, Maoyuan; Liu, Gui-Bin; Guo, Hong; Yao, Yugui

    2018-03-01

    In first-principles calculations, hybrid functional is often used to improve accuracy from local exchange correlation functionals. A drawback is that evaluating the hybrid functional needs significantly more computing effort. When spin-orbit coupling (SOC) is taken into account, the non-collinear spin structure increases computing effort by at least eight times. As a result, hybrid functional calculations with SOC are intractable in most cases. In this paper, we present an approximate solution to this problem by developing an efficient method based on a mixed linear combination of atomic orbital (LCAO) scheme. We demonstrate the power of this method using several examples and we show that the results compare very well with those of direct hybrid functional calculations with SOC, yet the method only requires a computing effort similar to that without SOC. The presented technique provides a good balance between computing efficiency and accuracy, and it can be extended to magnetic materials.

  5. Infusion tomography and ultrasonography of the gallbladder in the diagnosis of acute cholecystitis

    International Nuclear Information System (INIS)

    Karp, W.; Owman, T.; Herlin, P.; Holmin, T.

    1979-01-01

    Sixty-three patients with the clinical suspicion of acute cholecystitis were examined with infusion tomography of the gallbladder. Ultrasonography was performed in 51 of these cases. The technique and diagnostic principles of both methods are discussed. The diagnostic value of the two methods when used in combination is stressed. Thus in a case of gangrenous cholecystitis when opacification of the gallbladder wall may not appear at infusion tomography, ultrasonography may demonstrate signs of gallbladder disease. Infusion tomography, on the other hand, may be of great value if ultrasonography is not informative. (orig.) 891 AJ/orig. 892 BRE [de

  6. Hybrid design method for air-core solenoid with axial homogeneity

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Li; Lee, Sang Jin [Uiduk University, Gyeongju (Korea, Republic of); Choi, Suk Jin [Institute for Basic Science, Daejeon (Korea, Republic of)

    2016-03-15

    In this paper, a hybrid method is proposed to design an air-core superconducting solenoid system for 6 T axial uniform magnetic field using Niobium Titanium (NbTi) superconducting wire. In order to minimize the volume of conductor, the hybrid optimization method including a linear programming and a nonlinear programming was adopted. The feasible space of solenoid is divided by several grids and the magnetic field at target point is approximated by the sum of magnetic field generated by an ideal current loop at the center of each grid. Using the linear programming, a global optimal current distribution in the feasible space can be indicated by non-zero current grids. Furthermore the clusters of the non-zero current grids also give the information of probable solenoids in the feasible space, such as the number, the shape, and so on. Applying these probable solenoids as the initial model, the final practical configuration of solenoids with integer layers can be obtained by the nonlinear programming. The design result illustrates the efficiency and the flexibility of the hybrid method. And this method can also be used for the magnet design which is required the high homogeneity within several ppm (parts per million)

  7. Hybrid subgroup decomposition method for solving fine-group eigenvalue transport problems

    International Nuclear Information System (INIS)

    Yasseri, Saam; Rahnema, Farzad

    2014-01-01

    Highlights: • An acceleration technique for solving fine-group eigenvalue transport problems. • Coarse-group quasi transport theory to solve coarse-group eigenvalue transport problems. • Consistent and inconsistent formulations for coarse-group quasi transport theory. • Computational efficiency amplified by a factor of 2 using hybrid SGD for 1D BWR problem. - Abstract: In this paper, a new hybrid method for solving fine-group eigenvalue transport problems is developed. This method extends the subgroup decomposition method to efficiently couple a new coarse-group quasi transport theory with a set of fixed-source transport decomposition sweeps to obtain the fine-group transport solution. The advantages of the quasi transport theory are its high accuracy, straight-forward implementation and numerical stability. The hybrid method is analyzed for a 1D benchmark problem characteristic of boiling water reactors (BWR). It is shown that the method reproduces the fine-group transport solution with high accuracy while increasing the computational efficiency up to 12 times compared to direct fine-group transport calculations

  8. Assessment of implantable infusion pumps for continuous infusion of human insulin in rats: potential for group housing

    DEFF Research Database (Denmark)

    Jensen, Vivi Flou Hjorth; Molck, Anne-Marie; Martensson, Martin

    2017-01-01

    compound in these studies, and a comparator model of persistent exposure by HI infusion from external pumps has recently been developed to support toxicological evaluation of long-acting insulin analogues. However, this model requires single housing of the animals. Developing an insulin-infusion model...... which allows group housing would therefore greatly improve animal welfare. The aim of the present study was to investigate the suitability of implantable infusion pumps for HI infusion in group-housed rats. Group housing of rats implanted with a battery-driven pump proved to be possible. Intravenous...... infusion of HI lowered blood glucose levels persistently for two weeks, providing a comparator model for use in two-week repeated-dose toxicity studies with new long-acting insulin analogues, which allows group housing, and thereby increasing animal welfare compared with an external infusion model....

  9. A multigrid solution method for mixed hybrid finite elements

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, W. [Universitaet Augsburg (Germany)

    1996-12-31

    We consider the multigrid solution of linear equations arising within the discretization of elliptic second order boundary value problems of the form by mixed hybrid finite elements. Using the equivalence of mixed hybrid finite elements and non-conforming nodal finite elements, we construct a multigrid scheme for the corresponding non-conforming finite elements, and, by this equivalence, for the mixed hybrid finite elements, following guidelines from Arbogast/Chen. For a rectangular triangulation of the computational domain, this non-conforming schemes are the so-called nodal finite elements. We explicitly construct prolongation and restriction operators for this type of non-conforming finite elements. We discuss the use of plain multigrid and the multilevel-preconditioned cg-method and compare their efficiency in numerical tests.

  10. Software Engineering Technology Infusion Within NASA

    Science.gov (United States)

    Zelkowitz, Marvin V.

    1996-01-01

    Abstract technology transfer is of crucial concern to both government and industry today. In this paper, several software engineering technologies used within NASA are studied, and the mechanisms, schedules, and efforts at transferring these technologies are investigated. The goals of this study are: 1) to understand the difference between technology transfer (the adoption of a new method by large segments of an industry) as an industry-wide phenomenon and the adoption of a new technology by an individual organization (called technology infusion); and 2) to see if software engineering technology transfer differs from other engineering disciplines. While there is great interest today in developing technology transfer models for industry, it is the technology infusion process that actually causes changes in the current state of the practice.

  11. A Laplace transform method for energy multigroup hybrid discrete ordinates

    International Nuclear Information System (INIS)

    Segatto, C.F.; Vilhena, M.T.; Barros, R.C.

    2010-01-01

    In typical lattice cells where a highly absorbing, small fuel element is embedded in the moderator, a large weakly absorbing medium, high-order transport methods become unnecessary. In this work we describe a hybrid discrete ordinates (S N) method for energy multigroup slab lattice calculations. This hybrid S N method combines the convenience of a low-order S N method in the moderator with a high-order S N method in the fuel. The idea is based on the fact that in weakly absorbing media whose physical size is several neutron mean free paths in extent, even the S 2 method (P 1 approximation), leads to an accurate result. We use special fuel-moderator interface conditions and the Laplace transform (LTS N ) analytical numerical method to calculate the two-energy group neutron flux distributions and the thermal disadvantage factor. We present numerical results for a range of typical model problems.

  12. A hybrid method for accurate star tracking using star sensor and gyros.

    Science.gov (United States)

    Lu, Jiazhen; Yang, Lie; Zhang, Hao

    2017-10-01

    Star tracking is the primary operating mode of star sensors. To improve tracking accuracy and efficiency, a hybrid method using a star sensor and gyroscopes is proposed in this study. In this method, the dynamic conditions of an aircraft are determined first by the estimated angular acceleration. Under low dynamic conditions, the star sensor is used to measure the star vector and the vector difference method is adopted to estimate the current angular velocity. Under high dynamic conditions, the angular velocity is obtained by the calibrated gyros. The star position is predicted based on the estimated angular velocity and calibrated gyros using the star vector measurements. The results of the semi-physical experiment show that this hybrid method is accurate and feasible. In contrast with the star vector difference and gyro-assisted methods, the star position prediction result of the hybrid method is verified to be more accurate in two different cases under the given random noise of the star centroid.

  13. An accelerated hybrid TLM-IE method for the investigation of shielding effectiveness

    Directory of Open Access Journals (Sweden)

    N. Fichtner

    2010-09-01

    Full Text Available A hybrid numerical technique combining time-domain integral equations (TD-IE with the transmission line matrix (TLM method is presented for the efficient modeling of transient wave phenomena. This hybrid method allows the full-wave modeling of circuits in the time-domain as well as the electromagnetic coupling of remote TLM subdomains using integral equations (IE. By using the integral equations the space between the TLM subdomains is not discretized and consequently doesn't contribute to the computational effort. The cost for the evaluation of the time-domain integral equations (TD-IE is further reduced using a suitable plane-wave representation of the source terms. The hybrid TD-IE/TLM method is applied in the computation of the shielding effectiveness (SE of metallic enclosures.

  14. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  15. Microsurgical training on an in vitro chicken wing infusion model.

    Science.gov (United States)

    Olabe, Jon; Olabe, Javier

    2009-12-01

    Microneurovascular anastomosis and aneurysm clipping require extensive training before mastering the technique and are a surgical challenge. We developed the "infused chicken wing method" to provide a simple but realistic training method minimizing animal use and need for special facilities for animal care and anesthesia. Fresh chicken wings were used in this model. The main brachial artery was cannulated, and water was infused at 140 mm Hg followed by anatomical neurovascular dissection. Multiple microsurgical training exercises were performed under microscope vision including terminoterminal, lateroterminal, laterolateral vascular anastomosis, and nerve anastomosis. Different complexity aneurysms were created using venous patches, clipping, rupture, and vascular reconstruction techniques were performed. This novel training model is inexpensive, easily obtainable, and no live animals are required. The diameter and characteristics of arteries and veins used are similar to those of the human brain. Great microsurgical technique progress may be obtained. The infused chicken wing artery model presents a realistic microvascular training method. It is inexpensive and easy to set up. Such simplicity provides the adequate environment for developing microsurgical technique. Copyright 2009 Elsevier Inc. All rights reserved.

  16. Hybrid methods for airframe noise numerical prediction

    Energy Technology Data Exchange (ETDEWEB)

    Terracol, M.; Manoha, E.; Herrero, C.; Labourasse, E.; Redonnet, S. [ONERA, Department of CFD and Aeroacoustics, BP 72, Chatillon (France); Sagaut, P. [Laboratoire de Modelisation en Mecanique - UPMC/CNRS, Paris (France)

    2005-07-01

    This paper describes some significant steps made towards the numerical simulation of the noise radiated by the high-lift devices of a plane. Since the full numerical simulation of such configuration is still out of reach for present supercomputers, some hybrid strategies have been developed to reduce the overall cost of such simulations. The proposed strategy relies on the coupling of an unsteady nearfield CFD with an acoustic propagation solver based on the resolution of the Euler equations for midfield propagation in an inhomogeneous field, and the use of an integral solver for farfield acoustic predictions. In the first part of this paper, this CFD/CAA coupling strategy is presented. In particular, the numerical method used in the propagation solver is detailed, and two applications of this coupling method to the numerical prediction of the aerodynamic noise of an airfoil are presented. Then, a hybrid RANS/LES method is proposed in order to perform some unsteady simulations of complex noise sources. This method allows for significant reduction of the cost of such a simulation by considerably reducing the extent of the LES zone. This method is described and some results of the numerical simulation of the three-dimensional unsteady flow in the slat cove of a high-lift profile are presented. While these results remain very difficult to validate with experiments on similar configurations, they represent up to now the first 3D computations of this kind of flow. (orig.)

  17. Hybrid Cryogenic Tank Construction and Method of Manufacture Therefor

    Science.gov (United States)

    DeLay, Thomas K. (Inventor)

    2011-01-01

    A lightweight, high-pressure cryogenic tank construction includes an inner layer comprising a matrix of fiber and resin suitable for cryogenic use. An outer layer in intimate contact with the inner layer provides support of the inner layer, and is made of resin composite. The tank is made by placing a fiber preform on a mandrel and infusing the preform with the resin. The infused preform is then encapsulated within the outer layer.

  18. Infusion of iloprost without a peristaltic pump: Safety and tolerability

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2013-04-01

    Full Text Available Introduction: Iloprost is a potent prostacyclin (PGI2 analogue that is effective in the treatment of peripheral arterial disease, vasculitis, pulmonary hypertension, and secondary Raynaud’s phenomenon. Intravenous infusions are generally administered with the aid of a peristaltic pump to reduce the risk of adverse reactions caused by unintentional increases in the infusion rate. This increases the cost of care in terms of equipment and personnel and may limit the use of this drug. Materials and methods: We retrospectively analyzed 18,432 iloprost infusions administered between 1999 and 2009 to 272 patients with systemic sclerosis (n = 253 and 19 with peripheral arterial disease (n = 19. All infusions were administered in the day hospital over 6 h with a normal IV set-up with a roller flow regulator. Flow rates were set to deliver iloprost at 1-2 ng/kg/min. Rates were verified by direct drop counts during the first 15-20 minutes of the infusion and at each subsequent check. Results: There were no adverse events that were fatal, life-threatening, or associated with prolongation of hospitalization and very few events requiring intensive care or continuous monitoring. The latter included 4 cases of tachycardia/arrhythmia (extrasystoles in most cases, 3 cases of hypotension (systolic pressure < 80 mmHg, and 2 cases of hypertension (BP > 170/100 mmHg. All other adverse reactions were mild, reversible, and similar to those seen with iloprost infusion with peristaltic pump. Only one patient had to be switched to another prostanoid (due to intolerance. Discussion: Iloprost infusion administered with a normal IV flow regulator appears to be as safe, well tolerated, and effective as traditional infusion with a peristaltic pump.

  19. Optimization methods applied to hybrid vehicle design

    Science.gov (United States)

    Donoghue, J. F.; Burghart, J. H.

    1983-01-01

    The use of optimization methods as an effective design tool in the design of hybrid vehicle propulsion systems is demonstrated. Optimization techniques were used to select values for three design parameters (battery weight, heat engine power rating and power split between the two on-board energy sources) such that various measures of vehicle performance (acquisition cost, life cycle cost and petroleum consumption) were optimized. The apporach produced designs which were often significant improvements over hybrid designs already reported on in the literature. The principal conclusions are as follows. First, it was found that the strategy used to split the required power between the two on-board energy sources can have a significant effect on life cycle cost and petroleum consumption. Second, the optimization program should be constructed so that performance measures and design variables can be easily changed. Third, the vehicle simulation program has a significant effect on the computer run time of the overall optimization program; run time can be significantly reduced by proper design of the types of trips the vehicle takes in a one year period. Fourth, care must be taken in designing the cost and constraint expressions which are used in the optimization so that they are relatively smooth functions of the design variables. Fifth, proper handling of constraints on battery weight and heat engine rating, variables which must be large enough to meet power demands, is particularly important for the success of an optimization study. Finally, the principal conclusion is that optimization methods provide a practical tool for carrying out the design of a hybrid vehicle propulsion system.

  20. Strontium-rubidium infusion pump with in-line dosimetry

    International Nuclear Information System (INIS)

    Barker, S.L.; Loberg, M.D.

    1986-01-01

    A strontium-rubidium infusion system is described which consists of: (a) means for generating rubidium 82 in a solution which can be infused into a patient; (b) means for infusing the solution into a patient; (c) means for measuring the radioactivity present in the solution as it is infused into the patient; and (d) means for controlling the means for infusing in response to the amount of radioactivity which has been infused into the patient

  1. The U.S. home infusion market.

    Science.gov (United States)

    Monk-Tutor, M R

    1998-10-01

    Medicare legislation stimulated the development of home care services but also resulted in fragmentation of service components. In the 1980s, prospective pricing and diagnosis-related groups, and resulting pressures to reduce inpatient length of stay, prompted additional growth of the industry. Even so, in 1995 home care represented only 3% of total national expenditures on health care. The annual growth rate of the home infusion industry dropped from 64% in 1982-86 to 24% in 1986-93. While revenue per patient for home infusion is expected to decrease under managed care, an increasing number of patients will support continued market growth. The home infusion market is highly competitive, with only a few large national providers and many small local providers. In 1996, 29% of acute care hospitals provided or were developing a home care program. Community pharmacists' options in the home infusion area include independent services, partnerships, joint ventures, contracts with hospitals, and franchises. The home infusion market is being integrated into alternative sites, such as ambulatory infusion centers (AICs), as providers attempt to diversify to maintain managed care contracts. AICs provide infusion therapy and nursing to noninstitutionalized, nonhome-bound patients. Untapped sources for future growth of the infusion market include long-term-care facilities. More consistent studies of the home care market are needed. Despite slowed growth in recent years, home care has a strong market in the United States.

  2. The regulatory system for diabetes mellitus: Modeling rates of glucose infusions and insulin injections

    Science.gov (United States)

    Yang, Jin; Tang, Sanyi; Cheke, Robert A.

    2016-08-01

    Novel mathematical models with open and closed-loop control for type 1 or type 2 diabetes mellitus were developed to improve understanding of the glucose-insulin regulatory system. A hybrid impulsive glucose-insulin model with different frequencies of glucose infusions and insulin injections was analyzed, and the existence and uniqueness of the positive periodic solution for type 1 diabetes, which is globally asymptotically stable, was studied analytically. Moreover, permanence of the system for type 2 diabetes was demonstrated which showed that the glucose concentration level is uniformly bounded above and below. To investigate how to prevent hyperinsulinemia and hyperglycemia being caused by this system, we developed a model involving periodic intakes of glucose with insulin injections applied only when the blood glucose level reached a given critical glucose threshold. In addition, our numerical analysis revealed that the period, the frequency and the dose of glucose infusions and insulin injections are crucial for insulin therapies, and the results provide clinical strategies for insulin-administration practices.

  3. Diamond difference method with hybrid angular quadrature applied to neutron transport problems

    International Nuclear Information System (INIS)

    Zani, Jose H.; Barros, Ricardo C.; Alves Filho, Hermes

    2005-01-01

    In this work we presents the results for the calculations of the disadvantage factor in thermal nuclear reactor physics. We use the one-group discrete ordinates (S N ) equations to mathematically model the flux distributions in slab lattices. We apply the diamond difference method with source iteration iterative scheme to numerically solve the discretized systems equations. We used special interface conditions to describe the method with hybrid angular quadrature. We show numerical results to illustrate the accuracy of the hybrid method. (author)

  4. The usefulness of levin tube inserted drip infusion spiral CT: comparison with conventional method in subtotal gastrectomy patients

    International Nuclear Information System (INIS)

    Park, Young Jin; Kim, Young Hwan; Yoon, Jung Hee; Cha, Soon Joo; Kim, Jeong Sook; Kim, Sung Rok; Hur, Gham; Rhim, Hyun Chul

    1998-01-01

    The purpose of this study is to access the usefulness of newly designed Levin tube inserted drip infusion spiral CT for the evaluation of remnant stomach and anastomosis site in patients who have undergone subtotal gastrectomy for stomach cancer. A new technique named Levin tube inserted drip infusion spiral CT was used to prospectively study 23 patients. A 16Fr Levin tube was inserted into the remnant stomach; 500 ml of tap water was drip infused just before CT scanning and an additional 500 ml of water was infused during IV contrast injection. Water was infused by gravity, using a water bottle suspended at a height of 90 cm (Group A). The 31 patients who underwent conventional spiral CT scanning immediately after the divided ingestion of 900 ml diluted gastrografin were selected as a control group (Group B). The anatomic delineation of the anastomosis site was graded by two radiologists as excellent (3), good(2), fair (1) or poor (0). To evaluate the degree of distension, the maximal diameters of remnant stomach and the anastomosis site, and the thickness of the stomach wall, were also measured. In patients who had undergone subtobal gastrectomy, Levin tube inserted drip infusion spiral CT showed excellent anatomic delineation of the site of anastomosis and remnant stomach. We found that because it increases the distension of remnant stomach and the anastomosis site, this technique is effective for the evaluation of postoperative stomach. (author). 10 refs., 2 tabs., 3 figs

  5. Fuzzy Shannon Entropy: A Hybrid GIS-Based Landslide Susceptibility Mapping Method

    Directory of Open Access Journals (Sweden)

    Majid Shadman Roodposhti

    2016-09-01

    Full Text Available Assessing Landslide Susceptibility Mapping (LSM contributes to reducing the risk of living with landslides. Handling the vagueness associated with LSM is a challenging task. Here we show the application of hybrid GIS-based LSM. The hybrid approach embraces fuzzy membership functions (FMFs in combination with Shannon entropy, a well-known information theory-based method. Nine landslide-related criteria, along with an inventory of landslides containing 108 recent and historic landslide points, are used to prepare a susceptibility map. A random split into training (≈70% and testing (≈30% samples are used for training and validation of the LSM model. The study area—Izeh—is located in the Khuzestan province of Iran, a highly susceptible landslide zone. The performance of the hybrid method is evaluated using receiver operating characteristics (ROC curves in combination with area under the curve (AUC. The performance of the proposed hybrid method with AUC of 0.934 is superior to multi-criteria evaluation approaches using a subjective scheme in this research in comparison with a previous study using the same dataset through extended fuzzy multi-criteria evaluation with AUC value of 0.894, and was built on the basis of decision makers’ evaluation in the same study area.

  6. Effect of corticosteroids on phlebitis induced by intravenous infusion of antineoplastic agents in rabbits.

    Science.gov (United States)

    Kohno, Emiko; Murase, Saori; Matsuyama, Kenji; Okamura, Noboru

    2009-08-06

    Phlebitis caused by intravenous infusion of antineoplastic agents is one of the critical problems when anticancer therapy is prolonged. We have already reported that both rapid infusion and dilution of the injection solution were effective methods for reducing phlebitis caused by vinorelbine (VNR) in rabbits. The aim of this study was to explore other practical methods for preventing phlebitis caused by VNR and doxorubicin (DXR) in a rabbit model. VNR is often used with cisplatin, and dexamethasone (DEX) has been co-administered for prevention of cisplatin-induced nausea. DXR is used with prednisolone (PSL) in the CHOP regimen for the treatment of non-Hodgkin's lymphoma. Therefore, the present study investigated the prevention of phlebitis due to VNR with DEX and that due to DXR with PSL. VNR and DXR were diluted with normal saline to prepare test solutions at concentrations of 0.6 mg/mL and 1.4 mg/mL, respectively. Each test solution was infused into the auricular veins of rabbits. Two days after VNR infusion and three days after DXR infusion, the veins were evaluated histopathologically. The effect of DEX on VNR-induced phlebitis was evaluated by infusion of DEX before or after VNR. The effect of PSL on DXR-induced phlebitis was similarly evaluated by co-infusion of PSL. The histopathological features of phlebitis caused by the antineoplastic agents differed between VNR and DXR: VNR did not cause the loss of venous endothelial cells, but caused inflammatory cell infiltration, edema, and epidermal degeneration. In contrast, DXR caused the loss of venous endothelial cells and chrondrocyte necrosis. Pre-treatment and post-treatment with DEX significantly decreased VNR-induced phlebitis compared with the control group and pre-treatment was particularly effective. Co-infusion of PSL also significantly decreased phlebitis caused by DXR, but its effect was less marked. The present findings suggested that pre-treatment with DEX may be a useful method for preventing

  7. Accuracy improvement of a hybrid robot for ITER application using POE modeling method

    International Nuclear Information System (INIS)

    Wang, Yongbo; Wu, Huapeng; Handroos, Heikki

    2013-01-01

    Highlights: ► The product of exponential (POE) formula for error modeling of hybrid robot. ► Differential Evolution (DE) algorithm for parameter identification. ► Simulation results are given to verify the effectiveness of the method. -- Abstract: This paper focuses on the kinematic calibration of a 10 degree-of-freedom (DOF) redundant serial–parallel hybrid robot to improve its accuracy. The robot was designed to perform the assembling and repairing tasks of the vacuum vessel (VV) of the international thermonuclear experimental reactor (ITER). By employing the product of exponentials (POEs) formula, we extended the POE-based calibration method from serial robot to redundant serial–parallel hybrid robot. The proposed method combines the forward and inverse kinematics together to formulate a hybrid calibration method for serial–parallel hybrid robot. Because of the high nonlinear characteristics of the error model and too many error parameters need to be identified, the traditional iterative linear least-square algorithms cannot be used to identify the parameter errors. This paper employs a global optimization algorithm, Differential Evolution (DE), to identify parameter errors by solving the inverse kinematics of the hybrid robot. Furthermore, after the parameter errors were identified, the DE algorithm was adopted to numerically solve the forward kinematics of the hybrid robot to demonstrate the accuracy improvement of the end-effector. Numerical simulations were carried out by generating random parameter errors at the allowed tolerance limit and generating a number of configuration poses in the robot workspace. Simulation of the real experimental conditions shows that the accuracy of the end-effector can be improved to the same precision level of the given external measurement device

  8. Accuracy improvement of a hybrid robot for ITER application using POE modeling method

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yongbo, E-mail: yongbo.wang@hotmail.com [Laboratory of Intelligent Machines, Lappeenranta University of Technology, FIN-53851 Lappeenranta (Finland); Wu, Huapeng; Handroos, Heikki [Laboratory of Intelligent Machines, Lappeenranta University of Technology, FIN-53851 Lappeenranta (Finland)

    2013-10-15

    Highlights: ► The product of exponential (POE) formula for error modeling of hybrid robot. ► Differential Evolution (DE) algorithm for parameter identification. ► Simulation results are given to verify the effectiveness of the method. -- Abstract: This paper focuses on the kinematic calibration of a 10 degree-of-freedom (DOF) redundant serial–parallel hybrid robot to improve its accuracy. The robot was designed to perform the assembling and repairing tasks of the vacuum vessel (VV) of the international thermonuclear experimental reactor (ITER). By employing the product of exponentials (POEs) formula, we extended the POE-based calibration method from serial robot to redundant serial–parallel hybrid robot. The proposed method combines the forward and inverse kinematics together to formulate a hybrid calibration method for serial–parallel hybrid robot. Because of the high nonlinear characteristics of the error model and too many error parameters need to be identified, the traditional iterative linear least-square algorithms cannot be used to identify the parameter errors. This paper employs a global optimization algorithm, Differential Evolution (DE), to identify parameter errors by solving the inverse kinematics of the hybrid robot. Furthermore, after the parameter errors were identified, the DE algorithm was adopted to numerically solve the forward kinematics of the hybrid robot to demonstrate the accuracy improvement of the end-effector. Numerical simulations were carried out by generating random parameter errors at the allowed tolerance limit and generating a number of configuration poses in the robot workspace. Simulation of the real experimental conditions shows that the accuracy of the end-effector can be improved to the same precision level of the given external measurement device.

  9. Early mechanism of action of arterially infused ethanol: an experimental study on the influence of infusion speed

    International Nuclear Information System (INIS)

    Han, Joon Koo

    1988-01-01

    Abdominal aortography and histopathologic examination after absolute ethanol infusion at fast (0.4cc/sec) and slow speed (0.04cc/sec) were performed on 16 rats (2 controls. 7 fast infusion group. 7 slow infusion group). Angiographic and histopathologic findings were correlated and the findings of slow and fast infusion groups were studied. The results are as follows: 1. Histopathologic findings of the fast infusion group revealed wide area of glomerular and tubular collapses, obliteration of the free space between the Bowmann's capsule and glomerulus, sloughing and loss of the endothelium, fresh thrombi attached to the wall, and cleavage of the muscle layer of the arteries. 2. Angiographic findings of the fast infusion group revealed luminal irregularity, early obstruction of the aorta and the renal arteries, and delayed circulation time. 3. Histopathologic findings of the slow infusion group revealed degenerated, coalesced red blood cell packed in the glomeruli, focal areas of severe glomerular and tubular damage on relatively normal background, endothelial and muscular damage of the arteries. 4. Angiographic findings of the slow infusion group revealed focal perfusion defect of the kidney, delayed circulation time, and mild luminal irregularity, but there was no obstruction of the major arteries. 5. In conclusion, author believes that endothelial damage and thrombus formation from the damaged vessel wall, as well as direct cytotoxicity and in situ emboli formation play a significant role in the embolic effect of absolute ethanol.

  10. some generalized two-step block hybrid numerov method for solving ...

    African Journals Online (AJOL)

    Nwokem et al.

    ABSTRACT. This paper proposes a class of generalized two-step Numerov methods, a block hybrid type for the direct solution of general second order ordinary differential equations. Both the main method and additional methods were derived via interpolation and collocation procedures. The basic properties of zero ...

  11. The efficacy of intraperitoneal saline infusion for percutaneous radiofrequency ablation for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Park, Soo Young; Tak, Won Young; Jeon, Seong Woo; Cho, Chang Min; Kweon, Young Oh; Kim, Sung Kook; Choi, Yong Hwan

    2010-01-01

    Objective: To evaluated the efficacy and safety of radiofrequency ablation (RFA) with intraperitoneal saline infusion. Background: Ultrasound-guided RFA is not always feasible due to the tumor location, possible adjacent tissue damage or poor sonographic identification. Patients and methods: Ultrasound-guided RFA with intraperitoneal saline infusion was performed in 116 patients between June 2001 and March 2008. Results: The overall technical feasibility of the intraperitoneal saline infusions was 90.5% (105 patients). The purposes of the intraperitoneal saline infusion were achieved in 100 patients (86.2%) by visualizing the tumor located in hepatic dome (47 patients), prevent adjacent organ damage (42 patients) and withdrawing overlying omentum (10 patients). Complete ablation of tumor was accomplished in 102 patients (87.9%). Complications associated with the treatment occurred in seven patients (6.0%). There was no case of adverse event directly related to intraperitoneal saline infusion. Conclusions: Intraperitoneal saline infusion is an effective and safe procedure that can be used to overcome the current limitations of ultrasound-guided RFA.

  12. Price forecasting of day-ahead electricity markets using a hybrid forecast method

    International Nuclear Information System (INIS)

    Shafie-khah, M.; Moghaddam, M. Parsa; Sheikh-El-Eslami, M.K.

    2011-01-01

    Research highlights: → A hybrid method is proposed to forecast the day-ahead prices in electricity market. → The method combines Wavelet-ARIMA and RBFN network models. → PSO method is applied to obtain optimum RBFN structure for avoiding over fitting. → One of the merits of the proposed method is lower need to the input data. → The proposed method has more accurate behavior in compare with previous methods. -- Abstract: Energy price forecasting in a competitive electricity market is crucial for the market participants in planning their operations and managing their risk, and it is also the key information in the economic optimization of the electric power industry. However, price series usually have a complex behavior due to their nonlinearity, nonstationarity, and time variancy. In this paper, a novel hybrid method to forecast day-ahead electricity price is proposed. This hybrid method is based on wavelet transform, Auto-Regressive Integrated Moving Average (ARIMA) models and Radial Basis Function Neural Networks (RBFN). The wavelet transform provides a set of better-behaved constitutive series than price series for prediction. ARIMA model is used to generate a linear forecast, and then RBFN is developed as a tool for nonlinear pattern recognition to correct the estimation error in wavelet-ARIMA forecast. Particle Swarm Optimization (PSO) is used to optimize the network structure which makes the RBFN be adapted to the specified training set, reducing computation complexity and avoiding overfitting. The proposed method is examined on the electricity market of mainland Spain and the results are compared with some of the most recent price forecast methods. The results show that the proposed hybrid method could provide a considerable improvement for the forecasting accuracy.

  13. Price forecasting of day-ahead electricity markets using a hybrid forecast method

    Energy Technology Data Exchange (ETDEWEB)

    Shafie-khah, M., E-mail: miadreza@gmail.co [Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Moghaddam, M. Parsa, E-mail: parsa@modares.ac.i [Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Sheikh-El-Eslami, M.K., E-mail: aleslam@modares.ac.i [Tarbiat Modares University, Tehran (Iran, Islamic Republic of)

    2011-05-15

    Research highlights: {yields} A hybrid method is proposed to forecast the day-ahead prices in electricity market. {yields} The method combines Wavelet-ARIMA and RBFN network models. {yields} PSO method is applied to obtain optimum RBFN structure for avoiding over fitting. {yields} One of the merits of the proposed method is lower need to the input data. {yields} The proposed method has more accurate behavior in compare with previous methods. -- Abstract: Energy price forecasting in a competitive electricity market is crucial for the market participants in planning their operations and managing their risk, and it is also the key information in the economic optimization of the electric power industry. However, price series usually have a complex behavior due to their nonlinearity, nonstationarity, and time variancy. In this paper, a novel hybrid method to forecast day-ahead electricity price is proposed. This hybrid method is based on wavelet transform, Auto-Regressive Integrated Moving Average (ARIMA) models and Radial Basis Function Neural Networks (RBFN). The wavelet transform provides a set of better-behaved constitutive series than price series for prediction. ARIMA model is used to generate a linear forecast, and then RBFN is developed as a tool for nonlinear pattern recognition to correct the estimation error in wavelet-ARIMA forecast. Particle Swarm Optimization (PSO) is used to optimize the network structure which makes the RBFN be adapted to the specified training set, reducing computation complexity and avoiding overfitting. The proposed method is examined on the electricity market of mainland Spain and the results are compared with some of the most recent price forecast methods. The results show that the proposed hybrid method could provide a considerable improvement for the forecasting accuracy.

  14. Hourly forecasting of global solar radiation based on multiscale decomposition methods: A hybrid approach

    International Nuclear Information System (INIS)

    Monjoly, Stéphanie; André, Maïna; Calif, Rudy; Soubdhan, Ted

    2017-01-01

    This paper introduces a new approach for the forecasting of solar radiation series at 1 h ahead. We investigated on several techniques of multiscale decomposition of clear sky index K_c data such as Empirical Mode Decomposition (EMD), Ensemble Empirical Mode Decomposition (EEMD) and Wavelet Decomposition. From these differents methods, we built 11 decomposition components and 1 residu signal presenting different time scales. We performed classic forecasting models based on linear method (Autoregressive process AR) and a non linear method (Neural Network model). The choice of forecasting method is adaptative on the characteristic of each component. Hence, we proposed a modeling process which is built from a hybrid structure according to the defined flowchart. An analysis of predictive performances for solar forecasting from the different multiscale decompositions and forecast models is presented. From multiscale decomposition, the solar forecast accuracy is significantly improved, particularly using the wavelet decomposition method. Moreover, multistep forecasting with the proposed hybrid method resulted in additional improvement. For example, in terms of RMSE error, the obtained forecasting with the classical NN model is about 25.86%, this error decrease to 16.91% with the EMD-Hybrid Model, 14.06% with the EEMD-Hybid model and to 7.86% with the WD-Hybrid Model. - Highlights: • Hourly forecasting of GHI in tropical climate with many cloud formation processes. • Clear sky Index decomposition using three multiscale decomposition methods. • Combination of multiscale decomposition methods with AR-NN models to predict GHI. • Comparison of the proposed hybrid model with the classical models (AR, NN). • Best results using Wavelet-Hybrid model in comparison with classical models.

  15. 21 CFR 880.5725 - Infusion pump.

    Science.gov (United States)

    2010-04-01

    ... Infusion pump. (a) Identification. An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Infusion pump. 880.5725 Section 880.5725 Food and...

  16. Hybrid Fourier pseudospectral/discontinuous Galerkin time-domain method for wave propagation

    Science.gov (United States)

    Pagán Muñoz, Raúl; Hornikx, Maarten

    2017-11-01

    The Fourier Pseudospectral time-domain (Fourier PSTD) method was shown to be an efficient way of modelling acoustic propagation problems as described by the linearized Euler equations (LEE), but is limited to real-valued frequency independent boundary conditions and predominantly staircase-like boundary shapes. This paper presents a hybrid approach to solve the LEE, coupling Fourier PSTD with a nodal Discontinuous Galerkin (DG) method. DG exhibits almost no restrictions with respect to geometrical complexity or boundary conditions. The aim of this novel method is to allow the computation of complex geometries and to be a step towards the implementation of frequency dependent boundary conditions by using the benefits of DG at the boundaries, while keeping the efficient Fourier PSTD in the bulk of the domain. The hybridization approach is based on conformal meshes to avoid spatial interpolation of the DG solutions when transferring values from DG to Fourier PSTD, while the data transfer from Fourier PSTD to DG is done utilizing spectral interpolation of the Fourier PSTD solutions. The accuracy of the hybrid approach is presented for one- and two-dimensional acoustic problems and the main sources of error are investigated. It is concluded that the hybrid methodology does not introduce significant errors compared to the Fourier PSTD stand-alone solver. An example of a cylinder scattering problem is presented and accurate results have been obtained when using the proposed approach. Finally, no instabilities were found during long-time calculation using the current hybrid methodology on a two-dimensional domain.

  17. Groundwater flow analysis using mixed hybrid finite element method for radioactive waste disposal facilities

    International Nuclear Information System (INIS)

    Aoki, Hiroomi; Shimomura, Masanori; Kawakami, Hiroto; Suzuki, Shunichi

    2011-01-01

    In safety assessments of radioactive waste disposal facilities, ground water flow analysis are used for calculating the radionuclide transport pathway and the infiltration flow rate of groundwater into the disposal facilities. For this type of calculations, the mixed hybrid finite element method has been used and discussed about the accuracy of ones in Europe. This paper puts great emphasis on the infiltration flow rate of groundwater into the disposal facilities, and describes the accuracy of results obtained from mixed hybrid finite element method by comparing of local water mass conservation and the reliability of the element breakdown numbers among the mixed hybrid finite element method, finite volume method and nondegenerated finite element method. (author)

  18. Animal model of rapid crystalloid infusion in rats

    Directory of Open Access Journals (Sweden)

    Flavio Stillitano Orgaes

    2013-04-01

    Full Text Available PURPOSE: To describe an animal model of rapid intravenous infusion with different volumes of crystalloid and discuss the clinical findings. METHODS: Fifty six male Wistar rats were used, divided randomly in seven groups (n = 8. The rats of groups 1 to 6 received lactated Ringer´s solution intravenously, in the rate of 25 ml/min, with different volumes proportional to blood volume (BV. The rats of group 0 were submitted to the same procedure, but did not receive the fluid (control group. The data included respiratory rate, heart rate, saturation of peripheral oxygen (SpO2 in two times (before and after the infusion, and upshots (respiratory arrest and death. Dunnett´s test and ANOVA were used. RESULTS: The clinical signs significantly changed in the 2, 2.5 and 3 fold BV groups. The respiratory arrest was observed in the 1.5, 2, 2.5 and 3 fold BV groups, but death was present only in 2.5 and 3 fold BV groups. CONCLUSIONS: The infusion of crystalloid in the same volume of blood volume did not cause significant variation in respiratory and heart rate, saturation of peripheral oxygen and did not induce respiratory arrest. The infusion of a volume of 3 fold blood volume was lethal to all animals.

  19. Rapid-Infusion Rituximab in Lymphoma Treatment: 2-Year Experience in a Single Institution

    Science.gov (United States)

    Atay, Sevcan; Barista, Ibrahim; Gundogdu, Fatma; Akgedik, Kiymet; Arpaci, Afey

    2012-01-01

    Purpose: Rituximab is a chimeric anti-CD20 monoclonal antibody. We aimed to explore the safety and tolerability of rapid infusion rituximab, (over 90 minutes) in patients with non-Hodgkin's lymphoma at Hacettepe University Department of Medical Oncology. Patients and Methods: Adult patients diagnosed with non-Hodgkin's lymphoma who were to receive rituximab were included in the study. The schedule of administration for cycle 1 was unaltered and delivered according to the product monograph. All subsequent cycles were administered over a total infusion time of 90 minutes (20% of the dose in the first 30 minutes, then the remaining 80% over 60 minutes, total dose delivered in 500 mL). All patients were observed for infusion-related reactions during the rituximab infusion, and vital signs were recorded every 15 minutes. Results: From July 2006 to December 2008, 75 patients with non-Hodgkin's lymphoma were treated with rituximab-based chemotherapy. A total of 372 infusions were administered. The majority of patients were treated with rituximab plus cyclophosphamide, doxorubicin, vincristine, and prednisone, or rituximab only. The 90-minute rituximab infusion schedule was well tolerated, with no grade 3 or 4 infusion-related adverse events observed. Conclusion: A rapid infusion rituximab over 90 minutes is well tolerated and safe when administered as the second and subsequent infusions in the course of therapy. PMID:22942806

  20. Continuous Intravenous Sub-Dissociative Dose Ketamine Infusion for Managing Pain in the Emergency Department

    OpenAIRE

    Motov, Sergey; Drapkin, Jefferson; Likourezos, Antonios; Beals, Tyler; Monfort, Ralph; Fromm, Christian; Marshall, John

    2018-01-01

    Introduction: Our objective was to describe dosing, duration, and pre- and post-infusion analgesic administration of continuous intravenous sub-dissociative dose ketamine (SDK) infusion for managing a variety of painful conditions in the emergency department (ED).  Methods: We conducted a retrospective chart review of patients aged 18 and older presenting to the ED with acute and chronic painful conditions who received continuous SDK infusion in the ED for a pe...

  1. [A Case of HPN, In Which QOL Improvement Was Achieved by Combining Continuous Infusion with Once-Weekly Intermittent Infusion - Contribution of Pharmacists to Health Promotion among Home Patients Receiving Infusion Therapy].

    Science.gov (United States)

    Takeda, Namihiro; Hamana, Tomoko; Oka, Toyoka; Hirohara, Masayoshi; Kushida, Kazuki

    2016-12-01

    Patients receiving parenteral nutrition at home have the following two options: 24-h continuous or intermittent infusion. To date, for patients with impaired glucose tolerance and/or other metabolic disorders or for those with decreased cardiac/ pulmonary/renal function, it is desirable to opt for continuous infusion to minimize the variance in the body's metabolic rate as much as possible. Furthermore, it should be noted that continuous infusion evokes a stronger feeling among patients of being constrained because it restricts their everyday activities. This case witnesses collaborations among the patient's doctor, dispensary's pharmacy, and patient's family. Because ofthe use ofintermittent infusion more or less once per week in addition to continuous infusion, significant improvement in quality of life was achieved, and the patient was able to enjoy taking a short trip. To assist a home patient receiving infusion therapy, it is essential that the pharmacist be equipped with skills to manage risks associated with infusion therapy and have knowledge about insurance to cover incidents concerning infusion fluids or medical materials. It will certainly depend on the degree ofindependence ofpatients and the level ofcare their families can provide; however, should we manage to use a similar medical procedure in at least a few cases in the future, we may be able to contribute to "joie de vivre" in home patients receiving infusion therapy.

  2. A Hybrid 3D Path Planning Method for UAVs

    DEFF Research Database (Denmark)

    Ortiz-Arroyo, Daniel

    2015-01-01

    This paper presents a hybrid method for path planning in 3D spaces. We propose an improvement to a near-optimal 2D off-line algorithm and a flexible normalized on-line fuzzy controller to find shortest paths. Our method, targeted to low altitude domains, is simple and efficient. Our preliminary resu...

  3. Iloprost infusion by a new device as a portable syringe pump: safety, tolerability and agreement

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2012-12-01

    Full Text Available Background Iloprost, prostacyclin (PGI2 analogue, effective in treatment of peripheral arterial disease, secondary Raynaud's phenomenon (RP to connective tissue disease (CTD, vasculitis, pulmonary hypertension, is usually infused through peristaltic pump, or recently through a flow regulator.Materials and methods We tested a new portable syringe pump (Pompa Infonde®, Italfarmaco S.p.A., Cinisello Balsamo, Milano on 120 patients affected by RP to CTD and cryoglobulinaemia, in iloprost therapy with a flow regulator.Results Iloprost infused through portable syringe pump is better tolerated, better appreciated by the patients and nurses and no difference was observed on therapeutic effects, with a lower incidence of side effects statistically significant. Only 3 patients were unable to tolerate the device (2 for changes in pressure and 1 for fear and shifted to traditional method of iloprost infusion.Conclusions Iloprost infusion through the portable syringe Pompa Infonde® appears to be safe, better tolerated, more acceptable and equally effective compared to infusion through a flow regulator.

  4. A Nodal and Finite Difference Hybrid Method for Pin-by-Pin Heterogeneous Three-Dimensional Light Water Reactor Diffusion Calculations

    International Nuclear Information System (INIS)

    Lee, Deokjung; Downar, Thomas J.; Kim, Yonghee

    2004-01-01

    An innovative hybrid spatial discretization method is proposed to improve the computational efficiency of pin-wise heterogeneous three-dimensional light water reactor (LWR) core neutronics analysis. The newly developed method employs the standard finite difference method in the x and y directions and the well-known nodal methods [nodal expansion method (NEM) and analytic nodal method (ANM) as needed] in the z direction. Four variants of the hybrid method are investigated depending on the axial nodal methodologies: HYBRID A, NEM with the conventional quadratic transverse leakage; HYBRID B, the conventional NEM method except that the transverse-leakage shapes are obtained from a fine-mesh local problem (FMLP) around the control rod tip; HYBRID C, the same as HYBRID B except that ANM with a high-order transverse leakage obtained from the FMLP is used in the vicinity of the control rod tip; and HYBRID D, the same as HYBRID C except that the transverse leakage is determined using the buckling approximation instead of the FMLP around the control rod tip. Benchmark calculations demonstrate that all the hybrid algorithms are consistent and stable and that the HYBRID C method provides the best numerical performance in the case of rodded LWR problems with pin-wise homogenized cross sections

  5. Modeling, control, and simulation of grid connected intelligent hybrid battery/photovoltaic system using new hybrid fuzzy-neural method.

    Science.gov (United States)

    Rezvani, Alireza; Khalili, Abbas; Mazareie, Alireza; Gandomkar, Majid

    2016-07-01

    Nowadays, photovoltaic (PV) generation is growing increasingly fast as a renewable energy source. Nevertheless, the drawback of the PV system is its dependence on weather conditions. Therefore, battery energy storage (BES) can be considered to assist for a stable and reliable output from PV generation system for loads and improve the dynamic performance of the whole generation system in grid connected mode. In this paper, a novel topology of intelligent hybrid generation systems with PV and BES in a DC-coupled structure is presented. Each photovoltaic cell has a specific point named maximum power point on its operational curve (i.e. current-voltage or power-voltage curve) in which it can generate maximum power. Irradiance and temperature changes affect these operational curves. Therefore, the nonlinear characteristic of maximum power point to environment has caused to development of different maximum power point tracking techniques. In order to capture the maximum power point (MPP), a hybrid fuzzy-neural maximum power point tracking (MPPT) method is applied in the PV system. Obtained results represent the effectiveness and superiority of the proposed method, and the average tracking efficiency of the hybrid fuzzy-neural is incremented by approximately two percentage points in comparison to the conventional methods. It has the advantages of robustness, fast response and good performance. A detailed mathematical model and a control approach of a three-phase grid-connected intelligent hybrid system have been proposed using Matlab/Simulink. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Infusion-related reactions to infliximab in patients with rheumatoid arthritis in a clinical practice setting: relationship to dose, antihistamine pretreatment, and infusion number.

    Science.gov (United States)

    Wasserman, Michael J; Weber, Deborah A; Guthrie, Judith A; Bykerk, Vivian P; Lee, Peter; Keystone, Edward C

    2004-10-01

    We describe infusion-related reactions to infliximab (during infusion or within 1 hour postinfusion) in patients with active rheumatoid arthritis (RA) treated in a quaternary care center. We followed 113 patients for a mean of 60.6 +/- 28.9 weeks, obtaining 10.5 +/- 4.9 infusions per patient. We observed 1183 infusions resulting in 104 infusion reactions (8.8%). All reactions resolved within several hours following cessation of the infusion and none was serious enough to warrant hospitalization. Reactions included allergic reactions (pruritus, urticaria) in 4.2% of infusions, cardiopulmonary (hypotension, hypertension, tachycardia) in 3.0%, and miscellaneous reactions (headache, nausea, vomiting) in 2.0%. Reactions occurred in 8.0% of 3 mg/kg infusions and in 10.3% of 5 mg/kg infusions. Reactions occurred in 13.2% of infusions that involved antihistamine pretreatment compared to only 7.5% of infusions that involved no pretreatment. At both infliximab doses, there was a similar frequency of infusion reactions in patients pretreated due to a previous infusion (12.6%) compared to those pretreated strictly based on infusion number (14.7%). A number of the reactions involving antihistamine pretreatment may be explained by known side effects of diphenhydramine, including headache, dizziness, nausea, and palpitations. Infusion-related reactions to infliximab were infrequent, rarely severe, and easily manageable. The frequency of reactions was equivalent in patients treated with 3 mg/kg compared to 5 mg/kg. Reactions were significantly more frequent in infusions where patients were pretreated with the antihistamine diphenhydramine, compared to those not involving pretreatment.

  7. Hybrid RANS/LES method for wind flow over complex terrain

    DEFF Research Database (Denmark)

    Bechmann, Andreas; Sørensen, Niels N.

    2010-01-01

    for flows at high Reynolds numbers. To reduce the computational cost of traditional LES, a hybrid method is proposed in which the near-wall eddies are modelled in a Reynolds-averaged sense. Close to walls, the flow is treated with the Reynolds-averaged Navier-Stokes (RANS) equations (unsteady RANS...... rough walls. Previous attempts of combining RANS and LES has resulted in unphysical transition regions between the two layers, but the present work improves this region by using a stochastic backscatter model. To demonstrate the ability of the proposed hybrid method, simulations are presented for wind...... the turbulent kinetic energy, whereas the new method captures the high turbulence levels well but underestimates the mean velocity. The presented results are for a relative mild configuration of complex terrain, but the proposed method can also be used for highly complex terrain where the benefits of the new...

  8. Extended infusion versus intermittent infusion of imipenem in the treatment of ventilator-associated pneumonia.

    Science.gov (United States)

    Ibrahim, Mohamed M; Tammam, Tarek Fouad; Ebaed, Mohy El Deen; Sarhan, Hatem A; Gad, Gamal F; Hussein, Amal K

    2017-01-01

    Mechanical ventilation support can be the main source of ventilator-associated pneumonia (VAP). VAP is a serious infection that may be associated with dangerous gram-negative bacteria mainly, and it leads to an increase in the mortality in the intensive care unit (ICU). Imipenem is one of the strongest antibiotics now available for treating VAP which is associated with gram-negative and gram-positive bacteria, and it belongs to beta-lactam antibiotic group (carbapenem). This study tried to investigate the efficacy of imipenem against VAP when it was infused within 180 min versus the efficacy when it was infused within 30-60 min. This study was conducted in main ICU in general hospital which consists of surgical and medical beds within 2 years. One hundred and eighty-seven patients were enrolled on it. This study is a retrospective cohort which was conducted within 2 years. The efficacy of imipenem which was administered by intermittent infusion (30-60 min) within first year was compared with the efficacy of imipenem which was administered by extended infusion (180 min) within second year in the field of VAP curing and cost reduction. All data were collected retrospectively from patient medical files and were statistically analyzed by SPSS version 20. The study was designed to measure clinical and cost reduction outcomes, mortality and hospital stay. The results indicated that there is a significant decrease in mortality, number of recurrent infection, and ICU stay length, and the number of mechanical ventilator days was associated with extended imipenem infusion during the second year of the study. The use of imipenem with extended infusion over 3 hours enhances its clinical outcomes in the treatment of VAP.

  9. Method and apparatus for controlling hybrid powertrain system in response to engine temperature

    Science.gov (United States)

    Martini, Ryan D; Spohn, Brian L; Lehmen, Allen J; Cerbolles, Teresa L

    2014-10-07

    A method for controlling a hybrid powertrain system including an internal combustion engine includes controlling operation of the hybrid powertrain system in response to a preferred minimum coolant temperature trajectory for the internal combustion engine.

  10. Understanding Infusion Pumps.

    Science.gov (United States)

    Mandel, Jeff E

    2018-04-01

    Infusion systems are complicated electromechanical systems that are used to deliver anesthetic drugs with moderate precision. Four types of systems are described-gravity feed, in-line piston, peristaltic, and syringe. These systems are subject to a number of failure modes-occlusion, disconnection, siphoning, infiltration, and air bubbles. The relative advantages of the various systems and some of the monitoring capabilities are discussed. A brief example of the use of an infusion system during anesthetic induction is presented. With understanding of the functioning of these systems, users may develop greater comfort.

  11. Battery control system for hybrid vehicle and method for controlling a hybrid vehicle battery

    Science.gov (United States)

    Bockelmann, Thomas R [Battle Creek, MI; Beaty, Kevin D [Kalamazoo, MI; Zou, Zhanijang [Battle Creek, MI; Kang, Xiaosong [Battle Creek, MI

    2009-07-21

    A battery control system for controlling a state of charge of a hybrid vehicle battery includes a detecting arrangement for determining a vehicle operating state or an intended vehicle operating state and a controller for setting a target state of charge level of the battery based on the vehicle operating state or the intended vehicle operating state. The controller is operable to set a target state of charge level at a first level during a mobile vehicle operating state and at a second level during a stationary vehicle operating state or in anticipation of the vehicle operating in the stationary vehicle operating state. The invention further includes a method for controlling a state of charge of a hybrid vehicle battery.

  12. Tensile properties of interwoven hemp/PET (Polyethylene Terephthalate) epoxy hybrid composites

    Science.gov (United States)

    Ahmad, M. A. A.; Majid, M. S. A.; Ridzuan, M. J. M.; Firdaus, A. Z. A.; Amin, N. A. M.

    2017-10-01

    This paper describes the experimental investigation of the tensile properties of interwoven Hemp/PET hybrid composites. The effect of hybridization of hemp (warp) with PET fibres (weft) on tensile properties was of interest. Hemp and PET fibres were selected as the reinforcing material while epoxy resin was chosen as the matrix. The interwoven Hemp/PET fabric was used to produce hybrid composite using a vacuum infusion process. The tensile test was conducted using Universal Testing Machine in accordance to the ASTM D638. The tensile properties of the interwoven Hemp/PET hybrid composite were then compared with the neat woven hemp/epoxy composite. The results show that the strength of hemp/PET with the warp direction was increased by 8% compared to the neat woven hemp composite. This enhancement of tensile strength was due to the improved interlocking structure of interwoven Hemp/PET hybrid fabric.

  13. Swelling and infusion of tea in tea bags.

    Science.gov (United States)

    Yadav, Geeta U; Joshi, Bhushan S; Patwardhan, Ashwin W; Singh, Gurmeet

    2017-07-01

    The present study deals with swelling and infusion kinetics of tea granules in tea bags. The swelling and infusion kinetics of tea bags differing in tea loading and tea bag shapes were compared with loose tea. Increment in temperature and dipping frequency of tea bag in hot water increased the infusion kinetics of tea bags. Reduction in particle size enhanced the swelling and infusion kinetics of tea in a tea bag. The effects of tea particle size, tea bag dipping rate, loading of tea granules in tea bag and tea bag shapes on infusion kinetics were investigated. Increase in tea loading in tea bags resulted in reduced infusion kinetics. Double chambered tea bag showed the highest swelling (30%) and infusion kinetics (8.30% Gallic acid equivalence) while single chambered tea bags showed the lowest kinetics, amongst the various bags studied. The swelling and infusion kinetics of loose tea was always faster and higher than that of tea bags. It was found that overall effect of percentage filling of tea granules and height of tea bed in a tea bag affects tea infusion kinetics the most. Weibull model was found to be in good agreement with the swelling data.

  14. Apomorphine subcutaneous infusion, duodenal infusion of levodopa and deep brain stimulation – three advanced treatment options for the advanced Parkinson’s disease

    Directory of Open Access Journals (Sweden)

    Dušan Flisar

    2016-10-01

    Full Text Available Advanced stage of Parkinson's disease is associated with motor complications: motor fluctuations and dyskinesias. The disease can no longer be satisfactorily treated with oral therapy that is based on treatment with levodopa. Dying of dopamine neurons, a short half-life of levodopa and pulsatile stimulation of dopamine receptors are the main reasons for these complications. Currently, there are three options available to treat the advanced stage of Parkinson's disease: subcutaneous infusion of apomorphine, intrajejunal infusion of levodopa and deep brain stimulation. It is necessary to choose the optimal method of treatment that is most suitable for the individual patient.

  15. Continuous infusion thermodilution for assessment of coronary flow: Theoretical background and in vitro validation

    NARCIS (Netherlands)

    Veer, van 't M.; Geven, M.C.F.; Rutten, M.C.M.; Horst, van der A.; Aarnoudse, W.H.; Pijls, N.H.J.; Vosse, van de F.N.

    2009-01-01

    Direct volumetric assessment of coronary flow during cardiac catheterization has not been available so far. In the current study continuous infusion thermodilution, a method based on continuous infusion of saline into a selective coronary artery is evaluated. Theoretically, volumetric flow can be

  16. Power coordinated control method with frequency support capability for hybrid single/three-phase microgrid

    DEFF Research Database (Denmark)

    Zhou, Xiaoping; Chen, Yandong; Zhou, Leming

    2018-01-01

    storage unit (ESU) are added into hybrid single/three-phase microgrid, and a power coordinated control method with frequency support capability is proposed for hybrid single/three-phase microgrid in this study. PEU is connected with three single-phase microgrids to coordinate power exchange among three...... phases and provide frequency support for hybrid microgrid. Meanwhile, a power coordinated control method based on the droop control is proposed for PEU to alleviate three-phase power imbalance and reduce voltage fluctuation of hybrid microgrid. Besides, ESU is injected into the DC-link to buffer......Due to the intermittent output power of distributed generations (DGs) and the variability of loads, voltage fluctuation and three-phase power imbalance easily occur when hybrid single/three-phase microgrid operates in islanded mode. To address these issues, the power exchange unit (PEU) and energy...

  17. Clinical evaluation of preoperative arterial infusion chemotherapy and surgical operation for colorectal carcinoma

    International Nuclear Information System (INIS)

    Yuan Jianhua; Zhao Zhongsheng; Deng Gaoli; Hu Tingyang; Yu Wenqiang; Chen Fanghong; Luo Zuyan; Ru Guoqing; Dong Quanjin; Tu Shiliang

    2003-01-01

    Objective: To investigate the clinical values of preoperative arterial infusion chemotherapy and surgical operation for colorectal carcinoma. Methods: 66 patients with colorectal carcinoma were subjected to percutaneous femoral artery catheterization by Seldinger's technique with infusion of anti-cancer drugs. The resection was performed 5-30 days after the arterial infusion (mean 12 days). In 50 surgical specimens of the 66 cases, histological findings were evaluated including the density and distribution of the apoptosis cells under the observation by DNA nick end labelling technique. Of which 22 specimens before arterial infusion chemotherapy (got from biopsy of preoperation) and 25 normal mucosa (got from normal surgical specimens) were used as controls. Results: The total histological response rate was 100% with grade I in 20 cases, grade II in 21 cases, grade III in 9 cases. The densities of the apoptosis cells were 31.47 ± 5.58 before arterial infusion chemotherapy, 76.69 ± 17.12 after arterial infusion chemotherapy and 8.01 ± 3.39 in normal mucosa. The density of the apoptosis cells after arterial infusion chemotherapy was significantly higher than that before arterial infusion chemotherapy (P 2 =4.696, P>0.30). There were no significant differences in the apoptosis of adenocarcinoma during different pathological stages (F=0.001376, P>0.05). Conclusions: Peroperative transcatheter arterial infusion chemotherapy resulting in apoptosis of adenocarcinoma, can raise the radical operation rate, and prolong survival rate for colorectal carcinoma patients

  18. Intra-arterial and intraportal infusion liver scintigraphy using 99mTc-labeled colloid

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Ohtake, Tohru; Momose, Toshimitsu; Watanabe, Toshiaki; Kosaka, Noboru; Nishikawa, Jun-ichi; Sasaki, Yasuhito; Sawada, Toshio; Muto, Tetsuichiro

    1991-01-01

    Intra-arterial infusion liver scintigraphy was performed in 11 patients with primary or metastatic liver tumor. and intraportal infusion liver scintigraphy was performed in 6 patients for prophylaxis of liver metastasis from colorectal cancer. 99m Tc-Sn colloid or 99m Tc-phytate was administered through the catheter of which tip was placed in the portal vein or the hepatic artery, and then liver image was obtained. When 99m Tc-phytate was infused intra-arterially, significant amount of the infused tracer passed through the liver and we could not get sufficient information to assess the distribution of drug administered through the catheter. On the other hand, intraportal infusion liver scintigraphy using 99m Tc-Sn colloid or 99m Tc-phytate and intra-arterial infusion liver scintigraphy using 99m Tc-Sn colloid revealed heterogenity of liver uptake, tracer uptake in spleen, low uptake area corresponding to the liver tumor and high uptake area around it. The findings will be clinically useful, and these methods are thought to be helpful to confirm the satisfactory drug distribution. (author)

  19. Comparison between implicit and hybrid solvation methods for the ...

    Indian Academy of Sciences (India)

    Administrator

    Both implicit solvation method (dielectric polarizable continuum model, DPCM) and hybrid ... the free energy change (ΔGsol) as per the PCM ... Here the gas phase change is written as ΔGg = ΔEelec + ..... bution to the field of electrochemistry.

  20. Infusion's greenfield subsidiary in Poland

    NARCIS (Netherlands)

    Williams, C.; van Eerde, W.; The, D.

    2012-01-01

    The president of Infusion Development Corporation was reviewing the progress of the new subsidiary the company had set up 15 months earlier in Krakow, Poland. The purpose of the subsidiary was to work with other Infusion offices around the world to provide innovative software development services to

  1. Solution of the generalized Emden-Fowler equations by the hybrid functions method

    International Nuclear Information System (INIS)

    Tabrizidooz, H R; Marzban, H R; Razzaghi, M

    2009-01-01

    In this paper, we present a numerical algorithm for solving the generalized Emden-Fowler equations, which have many applications in mathematical physics and astrophysics. The method is based on hybrid functions approximations. The properties of hybrid functions, which consist of block-pulse functions and Lagrange interpolating polynomials, are presented. These properties are then utilized to reduce the computation of the generalized Emden-Fowler equations to a system of nonlinear equations. The method is easy to implement and yields very accurate results.

  2. Continuous Intravenous Sub-Dissociative Dose Ketamine Infusion for Managing Pain in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Jefferson Drapkin

    2018-03-01

    Full Text Available Introduction: Our objective was to describe dosing, duration, and pre- and post-infusion analgesic administration of continuous intravenous sub-dissociative dose ketamine (SDK infusion for managing a variety of painful conditions in the emergency department (ED. Methods: We conducted a retrospective chart review of patients aged 18 and older presenting to the ED with acute and chronic painful conditions who received continuous SDK infusion in the ED for a period over six years (2010–2016. Primary data analyses included dosing and duration of infusion, rates of pre- and post-infusion analgesic administration, and final diagnoses. Secondary data included pre- and post-infusion pain scores and rates of side effects. Results: A total of 104 patients were enrolled in the study. Average dosing of SDK infusion was 11.26 mg/hr, and the mean duration of infusion was 135.87 minutes. There was a 38% increase in patients not requiring post-infusion analgesia. The average decrease in pain score was 5.04. There were 12 reported adverse effects, with nausea being the most prevalent. Conclusion: Continuous intravenous SDK infusion has a role in controlling pain of various etiologies in the ED with a potential to reduce the need for co-analgesics or rescue analgesic administration. There is a need for more robust, prospective, randomized trials that will further evaluate the analgesic efficacy and safety of this modality across a wide range of pain syndromes and different age groups in the ED.

  3. Retrospective analysis of detomidine infusion for standing chemical restraint in 51 horses.

    Science.gov (United States)

    Wilson, D V; Bohart, G V; Evans, A T; Robertson, S; Rondenay, Y

    2002-01-01

    To assess the effectiveness of a detomidine infusion technique to provide standing chemical restraint in the horse. Retrospective study. Fifty-one adult horses aged 9.5 ± 6.9 years (range 1-23 years) and weighing 575 ± 290.3 kg. Records of horses presented to our clinic over a 3-year period in which a detomidine infusion was used to provide standing chemical restraint were reviewed. Information relating to the types of procedure performed, duration of infusion, drug dosages and adjunct drugs administered was retrieved. Detomidine was administered as an initial bolus loading dose (mean ± SD) of 7.5 ± 1.87 μg kg -1 . The initial infusion rate was 0.6 μg kg -1 minute -1 , and this was halved every 15 minutes. The duration of the infusion ranged from 20 to 135 minutes. Twenty horses received additional detomidine or butorphanol during the procedure. All horses undergoing surgery received local anesthesia or epidural analgesia in addition to the detomidine infusion. A wide variety of procedures were performed in these horses. Detomidine administered by infusion provides prolonged periods of chemical restraint in standing horses. Supplemental sedatives or analgesics may be needed in horses undergoing surgery. An effective method that provides prolonged periods of chemical restraint in standing horses is described. The infusion alone did not provide sufficient analgesia for surgery and a significant proportion of animals required supplemental sedatives and analgesics. Copyright © 2002 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  4. A direct hybrid S{sub N} method for slab-geometry lattice calculations

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Davi J.M.; Barros, Ricardo C., E-mail: rcbarros@pq.cnpq.b [Universidade do Estado do Rio de Janeiro (IPRJ/UERJ), Nova Friburgo, RJ (Brazil). Programa de Pos-graduacao em Modelagem Computacional; Zani, Jose H. [Fundacao Educacional Serra dos Orgaos, Teresopolis, RJ (Brazil). Ciencia da Computacao

    2011-07-01

    In this work we describe a hybrid direct method for calculating the thermal disadvantage factor and the neutron flux distribution in fuel-moderator lattices. For the mathematical model, we use the one-speed slab-geometry discrete ordinates (S{sub N}) transport equation with linearly anisotropic scattering. The basic idea is to use higher order angular quadrature set in the highly absorbing fuel region (S{sub NF}) and lower order angular quadrature set in the diffusive moderator region (S{sub NM}) , i.e., N{sub F} > N{sub M}. We apply special continuity conditions based on the equivalence of the S{sub N} and P{sub N-1} equations, which characterize the hybrid model. Numerical results to a typical model problem are given to illustrate the accuracy and the efficiency of the offered hybrid method. (author)

  5. Pharmacokinetics and toxicology of continuously infused nitroimidazoles

    International Nuclear Information System (INIS)

    Eifel, P.J.; Brown, J.M.

    1984-01-01

    The pharmacokinetics and toxicology of misonidazole (MISO) and SR-2508 given by continuous intraperitoneal infusion were studied in female C 3 H mice. The survival (time to death) of animals receiving continuous infusions of SR-2508 and MISO was compared and related to plasma concentration, rate of infusion and total amount of drug delivered. Brain and plasma concentrations were determined by HPLC. For SR-2508, plasma concentration was directly proportional to the infusion rate. However, as the infusion rate of MISO was doubled, the plasma concentration of MISO increased approximately 6-fold, reflecting a substantial increase in the apparent half-life. The brain/plasma concentration ratio in animals infused for up to 6 days with SR-2508 remained constant, at approximately 0.09. At plasma concentrations of 0.08-1.5 mM, animals receiving SR-2508 survived approximately 3 times as long as animals exposed to a comparable plasma concentration of MISO. Even at the lowest infusion rates employed in this study, the survival of mice receiving SR-2508 was much shorter than would have been predicted if the toxicity of these two drugs were solely related to the integral brain exposure. The low brain/plasma concentration ratio of SR-2508 was maintained throughout long continuous exposures

  6. MONITORING TETESAN INFUS BERBASIS MIKROKONTROLER ATMEGA16

    Directory of Open Access Journals (Sweden)

    Ardiyanto Iqbal Nugroho

    2015-09-01

    Penelitian ini menghasilkan suatu alat monitoring tetesan infus yang dapat memberikan informasi mengenai laju kecepatan tetesan dan kondisi cairan pada infus. Sistem yang secara realtime dimonitoring oleh perawat ini dapat mengurangi permasalahan yang timbul karena kelalaian petugas. Sehingga perawat tidak secara manual dalam mengatur kecepatan tetesan infus dan meningkatkan pelayanan kepada pasien.

  7. Propofol Infusion Syndrome: A Retrospective Analysis at a Level 1 Trauma Center

    Directory of Open Access Journals (Sweden)

    James H. Diaz

    2014-01-01

    Full Text Available Objectives. The propofol infusion syndrome (PRIS, a rare, often fatal, condition of unknown etiology, is defined by development of lipemic serum, metabolic acidosis, rhabdomyolysis, hepatomegaly, cardiac arrhythmias, and acute renal failure. Methods. To identify risk factors for and biomarkers of PRIS, a retrospective chart review of all possible PRIS cases during a 1-year period was conducted at a level 1 trauma hospital in ICU patients over 18 years of age receiving continuous propofol infusions for ≥3 days. Additional study inclusion criteria included vasopressor support and monitoring of serum triglycerides and creatinine. Results. Seventy-two patients, 61 males (84.7% and 11 females (15.3%, satisfied study inclusion criteria; and of these, 3 males met the study definition for PRIS, with 1 case fatality. PRIS incidence was 4.1% with a case-fatality rate of 33%. The mean duration of propofol infusion was 6.96 days. A positive linear correlation was observed between increasing triglyceride levels and infusion duration, but no correlation was observed between increasing creatinine levels and infusion duration. Conclusions. Risk factors for PRIS were confirmed as high dose infusions over prolonged periods. Increasing triglyceride levels may serve as reliable biomarkers of impending PRIS, if confirmed in future investigations with larger sample sizes.

  8. Determination of 24-hour insulin infusion pattern by an artificial endocrine pancreas for intravenous insulin infusion with a miniature pump

    DEFF Research Database (Denmark)

    Kølendorf, K; Christiansen, J S; Bojsen, J

    1981-01-01

    UNLABELLED: Intravenous insulin infusion with a glucose controlled insulin infusion system (GCIIS) is known to restore glucose homeostasis. A simpler approach to improve blood glucose regulation is preprogrammed intravenous insulin infusion with portable pumps without sensor-mediated feedback. We...... report a study designed to evaluate whether the preprogrammed insulin infusion pattern to be used in the miniature insulin infusion pump (MIIP) could be optimized by concomitant employment of the GCIIS for blood glucose control. Six juvenile-onset insulin-dependent diabetics (mean age 31 yrs) were...... studied. Mean blood glucose (MBG) was 6.2 mmol/l +/- 0.5 (SD) during glucose controlled infusion and 5.3 +/- 0.6 during the combined MIIP + GCIIS-day. The insulin requirements calculated from the s.c. regimen (56 U +/- 10 SD) were identical to the GCIIS-measured (51 U +/- 14) and to the amounts delivered...

  9. A Fifth Order Hybrid Linear Multistep method For the Direct Solution ...

    African Journals Online (AJOL)

    A linear multistep hybrid method (LMHM)with continuous coefficients isconsidered and directly applied to solve third order initial and boundary value problems (IBVPs). The continuous method is used to obtain Multiple Finite Difference Methods (MFDMs) (each of order 5) which are combined as simultaneous numerical ...

  10. Infusion of hypertonic saline before elective hysterectomy: effects on cytokines and stress hormones

    DEFF Research Database (Denmark)

    Kølsen-Petersen, Jens Aage; Bendtzen, Klaus; Tønnesen, Else Kirstine

    2008-01-01

    with the other groups (Peffect on the postoperative concentration of selected plasma cytokines and the hormonal stress......BACKGROUND: Infusion of hypertonic saline provides early haemodynamic benefits and may affect the immune system. It is unknown if infusion of hypertonic saline affects plasma cytokines and stress hormones after surgery. METHODS: Sixty-two women undergoing abdominal hysterectomy were randomized...

  11. Hybrid radical energy storage device and method of making

    Science.gov (United States)

    Gennett, Thomas; Ginley, David S; Braunecker, Wade; Ban, Chunmei; Owczarczyk, Zbyslaw

    2015-01-27

    Hybrid radical energy storage devices, such as batteries or electrochemical devices, and methods of use and making are disclosed. Also described herein are electrodes and electrolytes useful in energy storage devices, for example, radical polymer cathode materials and electrolytes for use in organic radical batteries.

  12. A theoretical alternative intraosseous infusion site in severely hypovolemic children

    Directory of Open Access Journals (Sweden)

    Nkhensani Mogale

    2015-07-01

    Full Text Available Background: Studies have shown that the venous system tends to collapse during hypovolemic shock. The use of the bone marrow space for infusions is an effective alternative, with the tibial insertion site being the norm. Objectives: This study was conducted to determine a quick intraosseous infusion method that could be an alternative to the tibial route in neonates during emergency situations. Method: A sample of 30 neonatal cadavers was dissected to explore a possible alternative to the tibial insertion site. The needle was inserted in the superolateral aspect of the humerus. The needle infusion site was then dissected to determine possible muscular and neurovascular damage that might occur during the administration of this procedure, with the greatest concern being the posterior circumflex humeral artery and axillary nerve exiting the quadrangular space. The distance of the needle insertion site was measured in relation to the soft tissue aswell as to bony landmarks. Results: The calculated 95% confidence interval shows that the needle can be safely inserted into the intraosseous tissue at the greater tubercle of the humerus 9.5 mm – 11.1 mm from the acromion. This is about a little finger’s width from the acromioclavicular joint. Conclusion: Anatomically, the described site is suggested to offer a safe alternative access point for emergency infusion in severely hypovolemic newborns and infants, without the risk of damage to any anatomical structures.

  13. Targeting chemotherapy via arterial infusion for advanced gastric cancer

    Directory of Open Access Journals (Sweden)

    Zhi-yu CAO

    2011-10-01

    Full Text Available Objective To evaluate the clinical effects of chemotherapy via arterial infusion in treatment of advanced gastric cancer.Methods Forty-seven patients with advanced gastric cancer were given chemotherapy via arterial infusion.Chemotherapy plan was as follows: 5-Fluorouracil(Fu 500mg/m2,cyclophosphamide(MMX 10mg/m2,Hydroxycamptothecin(HPT 20mg/m2,once per week,2 weeks as a course,a total of 2-3 courses.Results After chemotherapy via arterial infusion,complete remission(CR was achieved in 1 case,partial remission(PR in 28 cases,stabilization of disease(SD in 16 cases,progression of disease(PD was found in 2 cases,and rate with response(CR+PR was 61.7%.Four of 28 PR patients underwent tumorectomy,the pathology revealed the presence of cancer cells around the vascular vessels,manifesting karyopyknosis,karyorrhexis,coagulation and necrosis of cytoplasm,intercellular edema,hyperplasia of fibroblasts,inflammatory cell infiltration,thickening of endothelium,and thrombosis.One,two and three-year survival rates were 70.2%,14.9% and 2.1%,respectively.The average survival period was 17.2 months.Conclusion Targeting chemotherapy via arterial infusion,as a part of the combined treatment,is beneficial to the patients with unresectable advanced gastric cancer.

  14. Overview of hybrid subspace methods for uncertainty quantification, sensitivity analysis

    International Nuclear Information System (INIS)

    Abdel-Khalik, Hany S.; Bang, Youngsuk; Wang, Congjian

    2013-01-01

    Highlights: ► We overview the state-of-the-art in uncertainty quantification and sensitivity analysis. ► We overview new developments in above areas using hybrid methods. ► We give a tutorial introduction to above areas and the new developments. ► Hybrid methods address the explosion in dimensionality in nonlinear models. ► Representative numerical experiments are given. -- Abstract: The role of modeling and simulation has been heavily promoted in recent years to improve understanding of complex engineering systems. To realize the benefits of modeling and simulation, concerted efforts in the areas of uncertainty quantification and sensitivity analysis are required. The manuscript intends to serve as a pedagogical presentation of the material to young researchers and practitioners with little background on the subjects. We believe this is important as the role of these subjects is expected to be integral to the design, safety, and operation of existing as well as next generation reactors. In addition to covering the basics, an overview of the current state-of-the-art will be given with particular emphasis on the challenges pertaining to nuclear reactor modeling. The second objective will focus on presenting our own development of hybrid subspace methods intended to address the explosion in the computational overhead required when handling real-world complex engineering systems.

  15. Continuous infusion in haemophilia: current practice in Europe

    NARCIS (Netherlands)

    Batorova, A.; Holme, P.; Gringeri, A.; Richards, M.; Hermans, C.; Altisent, C.; Lopez-Fernández, M.; Fijnvandraat, K.

    2012-01-01

    . Continuous infusion (CI) of factor VIII (FVIII) is an effective method for replacement therapy in haemophilia. Recently, concerns have been raised regarding association of CI with the development of inhibitors. The aim of this study was to gain information on the current practices in Europe

  16. Infusing PDA technology into nursing education.

    Science.gov (United States)

    White, Ann; Allen, Patricia; Goodwin, Linda; Breckinridge, Daya; Dowell, Jeffery; Garvy, Ryan

    2005-01-01

    Use of the personal digital assistant (PDA) has been infused into the accelerated baccalaureate program at Duke University to help prepare nursing students for professional practice. The authors provide an overview of the use of PDAs in the classroom, laboratory, and clinical setting. Technical aspects of PDA infusion and steps to ensure regulatory compliance are explored. Benefits of PDA use by both faculty and students in the program and challenges met with the infusion of this technology are also described.

  17. Comparative Study of Continuous Pralidoxime Infusion versus Intermittent Dosing: Application of High-Performance Liquid Chromatography Method on Serum of Organophosphate Poisoned Patients

    Directory of Open Access Journals (Sweden)

    Girish Thunga

    2013-09-01

    How to cite this article: Thunga G, Pandey S, Nair S, Mylapuri R, Vidyasagar S, Kunhikatta V, et al. Comparative Study of Continuous Pralidoxime Infusion versus Intermittent Dosing: Application of High-Performance Liquid Chromatography Method on Serum of Organophosphate Poisoned Patients. Asia Pac J Med Toxicol 2013;2:105-10.

  18. Hybrid methods for cybersecurity analysis :

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Warren Leon,; Dunlavy, Daniel M.

    2014-01-01

    Early 2010 saw a signi cant change in adversarial techniques aimed at network intrusion: a shift from malware delivered via email attachments toward the use of hidden, embedded hyperlinks to initiate sequences of downloads and interactions with web sites and network servers containing malicious software. Enterprise security groups were well poised and experienced in defending the former attacks, but the new types of attacks were larger in number, more challenging to detect, dynamic in nature, and required the development of new technologies and analytic capabilities. The Hybrid LDRD project was aimed at delivering new capabilities in large-scale data modeling and analysis to enterprise security operators and analysts and understanding the challenges of detection and prevention of emerging cybersecurity threats. Leveraging previous LDRD research e orts and capabilities in large-scale relational data analysis, large-scale discrete data analysis and visualization, and streaming data analysis, new modeling and analysis capabilities were quickly brought to bear on the problems in email phishing and spear phishing attacks in the Sandia enterprise security operational groups at the onset of the Hybrid project. As part of this project, a software development and deployment framework was created within the security analyst work ow tool sets to facilitate the delivery and testing of new capabilities as they became available, and machine learning algorithms were developed to address the challenge of dynamic threats. Furthermore, researchers from the Hybrid project were embedded in the security analyst groups for almost a full year, engaged in daily operational activities and routines, creating an atmosphere of trust and collaboration between the researchers and security personnel. The Hybrid project has altered the way that research ideas can be incorporated into the production environments of Sandias enterprise security groups, reducing time to deployment from months and

  19. A Numerical Method for Lane-Emden Equations Using Hybrid Functions and the Collocation Method

    Directory of Open Access Journals (Sweden)

    Changqing Yang

    2012-01-01

    Full Text Available A numerical method to solve Lane-Emden equations as singular initial value problems is presented in this work. This method is based on the replacement of unknown functions through a truncated series of hybrid of block-pulse functions and Chebyshev polynomials. The collocation method transforms the differential equation into a system of algebraic equations. It also has application in a wide area of differential equations. Corresponding numerical examples are presented to demonstrate the accuracy of the proposed method.

  20. Short-Term Wind Power Forecasting Using the Enhanced Particle Swarm Optimization Based Hybrid Method

    Directory of Open Access Journals (Sweden)

    Wen-Yeau Chang

    2013-09-01

    Full Text Available High penetration of wind power in the electricity system provides many challenges to power system operators, mainly due to the unpredictability and variability of wind power generation. Although wind energy may not be dispatched, an accurate forecasting method of wind speed and power generation can help power system operators reduce the risk of an unreliable electricity supply. This paper proposes an enhanced particle swarm optimization (EPSO based hybrid forecasting method for short-term wind power forecasting. The hybrid forecasting method combines the persistence method, the back propagation neural network, and the radial basis function (RBF neural network. The EPSO algorithm is employed to optimize the weight coefficients in the hybrid forecasting method. To demonstrate the effectiveness of the proposed method, the method is tested on the practical information of wind power generation of a wind energy conversion system (WECS installed on the Taichung coast of Taiwan. Comparisons of forecasting performance are made with the individual forecasting methods. Good agreements between the realistic values and forecasting values are obtained; the test results show the proposed forecasting method is accurate and reliable.

  1. Selective cephalic upregulation of p-ERK, CamKII and p-CREB in response to glyceryl trinitrate infusion

    DEFF Research Database (Denmark)

    Ramachandran, Roshni; Pedersen, Sara Hougaard; Amrutkar, Dipak Vasantrao

    2018-01-01

    in the trigeminal and spinothalamic system after infusion of the migraine-provoking substance glyceryltrinitrate. Method A catheter was placed in the femoral vein of rats and one week later glyceryltrinitrate 4 µg/kg/min was infused for 20 min. Protein expression in the dura mater, trigeminal ganglion, nucleus...... glycerytrinitrate infusion ( P ... after glycerytrinitrate infusion with long-lasting expression of phosphorylated extracellular signal-regulated kinases observed in the nucleus caudalis. These activations were not observed at the spinal level....

  2. Hybrid vortex simulations of wind turbines using a three-dimensional viscous-inviscid panel method

    DEFF Research Database (Denmark)

    Ramos García, Néstor; Hejlesen, Mads Mølholm; Sørensen, Jens Nørkær

    2017-01-01

    adirect calculation, whereas the contribution from the large downstream wake is calculated using a mesh-based method. Thehybrid method is first validated in detail against the well-known MEXICO experiment, using the direct filament method asa comparison. The second part of the validation includes a study......A hybrid filament-mesh vortex method is proposed and validated to predict the aerodynamic performance of wind turbinerotors and to simulate the resulting wake. Its novelty consists of using a hybrid method to accurately simulate the wakedownstream of the wind turbine while reducing...

  3. Analysis of subgrid scale mixing using a hybrid LES-Monte-Carlo PDF method

    International Nuclear Information System (INIS)

    Olbricht, C.; Hahn, F.; Sadiki, A.; Janicka, J.

    2007-01-01

    This contribution introduces a hybrid LES-Monte-Carlo method for a coupled solution of the flow and the multi-dimensional scalar joint pdf in two complex mixing devices. For this purpose an Eulerian Monte-Carlo method is used. First, a complex mixing device (jet-in-crossflow, JIC) is presented in which the stochastic convergence and the coherency between the scalar field solution obtained via finite-volume methods and that from the stochastic solution of the pdf for the hybrid method are evaluated. Results are compared to experimental data. Secondly, an extensive investigation of the micromixing on the basis of assumed shape and transported SGS-pdfs in a configuration with practical relevance is carried out. This consists of a mixing chamber with two opposite rows of jets penetrating a crossflow (multi-jet-in-crossflow, MJIC). Some numerical results are compared to available experimental data and to RANS based results. It turns out that the hybrid LES-Monte-Carlo method could achieve a detailed analysis of the mixing at the subgrid level

  4. The effect of glucagon on infusion cholangiography

    International Nuclear Information System (INIS)

    Evans, A.F.; Whitehouse, G.H.

    1979-01-01

    An assessment has been made of the effects of glucagon on biliary tract opacification during intravenous cholangiography. Two series of infusion cholangiograms were obtained at two investigating centres designated A and B. In series A, 41 patients had ioglycamide infusions at a rate of 0.2833 g min -1 over 1 h. In series B, 31 patients had ioglycamide infusions at a rate of 0.3886 g min -1 over 30 min. Radiographs were taken in both series immediately at the end of the infusion, 10 min later and 30 min after the infusion. Two mg of intravenous glucagon was injected into alternate cases in both series A and B immediately after the first radiograph was taken at the completion of the ioglycamide infusion. Two observers in each series then assessed the radiographic opacification of the biliary system without prior knowledge of which patients had received the glucagon. Delineation of the biliary system was considered better in both series in those patients who received glucagon when compared with the controls. Gallbladder opacification was definitely increased in series A in those receiving glucagon, and a similar tendency was shown in series B. The amount of contrast in the upper intestine was increased in series A in the glucagon group, but not in series B. It is concluded that glucagon improves visualisation of the biliary tract, especially the gallbladder at infusion cholangiography. (author)

  5. Fabrication of Hybrid Organic Photovoltaic Devices Using Electrostatic Spray Method

    Directory of Open Access Journals (Sweden)

    Zhe-Wei Chiu

    2014-01-01

    Full Text Available Hybrid organic photovoltaic devices (OPVDs are fabricated using the electrostatic spray (e-spray method and their optical and electrical properties are investigated. E-spray is used to deposit a hybrid film (P3HT: PCBM/nanodiamond with morphology and optical characteristics onto OPVDs. The root-mean-square roughness and optical absorption increase with increasing nanodiamond content. The performance of e-spray is comparable to that of the spin-coating method under uniform conditions. The device takes advantage of the high current density, power conversion efficiency, and low cost. Nanodiamond improves the short-circuit current density and power conversion efficiency. The best performance was obtained with 1.5 wt% nanodiamond content, with a current density of 7.28 mA/cm2 and a power conversion efficiency of 2.25%.

  6. Comparison of Two Methods of Bolus and Infusion of Tranexamic Acid in Reduction of Blood Loss in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Mohammadreza Moshari

    2018-01-01

    Full Text Available AbstractBackground: So far, many studies have been performed to determine the optimal dose and regimen of tranexamic acid to reduce preoperative and postoperative blood loss in primary total knee arthroplasty. In the present study, two different methods of administration (bolus and infusion, were compared.Materials and Methods: Forty patients were randomized in the two groups (A and B of 20 patients each. All patients received 500 mg tranexamic acid before inflation of tourniquet. Group A (mean age, 64± 6.1 years received 500 mg tranexamic acid 10 minutes before loosening of tourniquet and group B (mean age, 63.5 ± 7.7 years received 500 mg tranexamic acid through IV infusion during 6 hours from the time of tourniquet loosening (total dose of TA, 1 g in both groups. Intraoperative blood loss,postoperative drainage (in 6 and 12 hours, blood transfusion (in 48 hours, and decrease in hematocrit and hemoglobin (6 and 12 hours later, were compared between the two groups.Results: The patients in group B had lower intra- and postoperative blood loss in 6 and 12 hours and also had lower decrease in hemoglobin, and their packed cell transfusion rate was significantly lower compared to the group A.Conclusion: The findings of this study indicated that infusion administration of tranexamic acid in primary total knee arthroplasty, was more effective in the reduction of perioperative blood loss as well as need for blood transfusion in 48 hours.

  7. Pulsatile versus steady infusions for hepatic artery chemotherapy

    International Nuclear Information System (INIS)

    Kim, E.E.; Haynie, T.P.; Wright, K.C.; Chaynsangavej, C.; Gianturco, C.; Lamki, L.; Wallace, S.

    1984-01-01

    Hepatic artery chemotherapy for unresectable liver tumors requires an even distribution of the drugs in the tumor or vascular bed. This cannot be determined angiographically because the drugs are infused at a much lower rate than the contrast media. It is easy, however, to determine the quality of the perfusion by injecting a small volume of Tc-99m MAA in one of the side ports while chemotherapeutic agent is being infused at the same rate. Usually this shows a uniform, satisfactory distribution of isotope. Occasionally, however, some areas fail to receive Tc-99m in spite of what appears to be a good position of the catheter tip. Since ''streaming'' of the infused drugs has been blamed for their uneven distribution, the authors decided to compare the usual steady flow infusions with infusions made pulsatile by the addition of a pulsing device (Gianturco Pump) attached to the infusion tubing. Eighty-three patients were studied with steady as well as pulsatile infusions. In 16 of these patients the perfusion pattern was definitely changed by the pulsatile infusion. In one patient the pulsatile mode resulted in an unwanted gastric perfusion. In 5 patients the distribution was improved in one hepatic lobe and in 10 patients it was improved in both lobes. These results show that hepatic artery perfusions can occasionally be improved by pulsing the infusate. However, pulsing can produce the unwanted perfusion of extra-hepatic areas

  8. Pharmacokinetics and analgesic effect of ropivacaine during continuous epidural infusion for postoperative pain relief

    DEFF Research Database (Denmark)

    Erichsen, C J; Sjövall, J; Kehlet, H

    1996-01-01

    BACKGROUND: The pharmacokinetics and clinical efficacy of ropivacaine (2.5 mg/ml) during a 24-h continuous epidural infusion for postoperative pain relief in 20 patients scheduled for abdominal hysterectomy were characterized using an open-label, increasing-dose design. METHODS: Through an epidural...... catheter inserted at T10-T12, a test dose of 7.5 mg ropivacaine was given 3 min before a bolus dose of 42.5 mg and immediately followed by a 24-h continuous epidural infusion with either 10 or 20 mg/h. Peripheral venous plasma samples were collected up to 48 h after infusion, and urinary excretion...... plasma concentrations of ropivacaine increased markedly and consistently during the 24-h epidural infusion, in contrast to stable unbound concentrations. Both total and unbound plasma concentrations at the end of infusion were proportional to the total dose, although only the latter was proportional...

  9. Complications Following Balloon-Occluded Arterial Infusion Chemotherapy for Pelvic Malignancies

    International Nuclear Information System (INIS)

    Sugimoto, Koji; Hirota, Shozo; Imanaka, Kazufumi; Kawabe, Tetsuya; Nakayama, Yoshiharu; Takeuchi, Yasuhito

    1999-01-01

    Purpose: To evaluate the incidence and causes of complications associated with balloon-occluded arterial infusion chemotherapy (BOAI) for pelvic malignancies. Methods: In 34 courses of BOAI in 22 patients with pelvic malignancies, we analyzed the incidence of complications as well as the effect of the dose of the anticancer drugs, the infusion site, and the number of BOAI administrations on these complications. Complications were divided into two categories: cystitis-like symptoms and neurological complications such as pain, numbness, and paresthesia of the lower extremities and the hip. Results: Eleven patients (50%) suffered from complications, seven (31.8%) from neurological complications and four (18.2%) from cystitis-like symptoms. The complications appeared in 14 courses (42.4%) of BOAI, neurological complications in 10 (30.3%) and cystitis-like symptoms in four (12.1%). A high dose of anti-cancer drugs and infusion from the anterior division tended to induce neurological complications more frequently; however, the cystitis-like symptoms were not related to any factors. Conclusion: Our results indicate that a smaller dose of anti-cancer drugs should be infused from the bilateral internal iliac arteries for safer pelvic BOAI

  10. Liquid-liquid displacement in slippery liquid-infused membranes (SLIMs)

    OpenAIRE

    Bazyar, Hanieh; Lv, Pengyu; Wood, Jeffery A.; Porada, Slawomir; Lohse, Detlef; Lammertink, Rob G. H.

    2018-01-01

    Liquid-infused membranes inspired by slippery liquid-infused porous surfaces (SLIPS) have been recently introduced to membrane technology. The gating mechanism of these membranes is expected to give rise to anti-fouling properties and multi-phase transport capabilities. However, the long-term retention of the infusion liquid has not yet been explored. To address this issue, we investigate the retention of the infusion liquid in slippery liquid-infused membranes (SLIMs) via liquid-liquid displ...

  11. Constant infusion transpulmonary thermodilution for the assessment of cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Calbet, J A L; Mortensen, Stefan; Munch, G D W

    2016-01-01

    To determine the accuracy and precision of constant infusion transpulmonary thermodilution cardiac output (CITT-Q) assessment during exercise in humans, using indocyanine green (ICG) dilution and bolus transpulmonary thermodilution (BTD) as reference methods, cardiac output (Q) was determined......: 6.1-11.1%). In conclusion, cardiac output can be precisely and accurately determined with constant infusion transpulmonary thermodilution in exercising humans....

  12. A scalable hybrid multi-robot SLAM method for highly detailed maps

    NARCIS (Netherlands)

    Pfingsthorn, M.; Slamet, B.; Visser, A.

    2008-01-01

    Recent successful SLAM methods employ hybrid map representations combining the strengths of topological maps and occupancy grids. Such representations often facilitate multi-agent mapping. In this paper, a successful SLAM method is presented, which is inspired by the manifold data structure by

  13. Comparison of Two Methods of Bolus and Infusion of Tranexamic Acid in Reduction of Blood Loss in Total Knee Arthroplasty

    OpenAIRE

    Mohammadreza Moshari; Bahman Malek; Mohammadreza Minator-Sajjadi; Maryam Vosoghian; Mastaneh Dahi; Mahshid Ghasemi; Razieh Shekari

    2018-01-01

    AbstractBackground: So far, many studies have been performed to determine the optimal dose and regimen of tranexamic acid to reduce preoperative and postoperative blood loss in primary total knee arthroplasty. In the present study, two different methods of administration (bolus and infusion), were compared.Materials and Methods: Forty patients were randomized in the two groups (A and B) of 20 patients each. All patients received 500 mg tranexamic acid before inflation of tourniquet. Group A (...

  14. Financial analysis for the infusion alliance.

    Science.gov (United States)

    Perucca, Roxanne

    2010-01-01

    Providing high-quality, cost-efficient care is a major strategic initiative of every health care organization. Today's health care environment is transparent; very competitive; and focused upon providing exceptional service, safety, and quality. Establishing an infusion alliance facilitates the achievement of organizational strategic initiatives, that is, increases patient throughput, decreases length of stay, prevents the occurrence of infusion-related complications, enhances customer satisfaction, and provides greater cost-efficiency. This article will discuss how to develop a financial analysis that promotes value and enhances the financial outcomes of an infusion alliance.

  15. Summary curves for patients transplanted for chronic myeloid leukaemia salvaged by a donor lymphocyte infusion: the current leukaemia-free survival curve

    DEFF Research Database (Denmark)

    Klein, John P.; Keiding, Niels; Shu, Youyi

    2000-01-01

    CML, donor lymphocyte infusion, leukaemia-free survival, current leukaemia-free survival, statistical methods......CML, donor lymphocyte infusion, leukaemia-free survival, current leukaemia-free survival, statistical methods...

  16. A Four-Step Block Hybrid Adams-Moulton Methods For The Solution ...

    African Journals Online (AJOL)

    This paper examines application of the Adam-Moulton's Method and proposes a modified self-starting continuous formula Called hybrid Adams-Moulton methods for the case k=4. It allows evaluation at both grid and off grid points to obtain the discrete schemes used in the block methods. The order, error constant and ...

  17. 3D magnetospheric parallel hybrid multi-grid method applied to planet–plasma interactions

    Energy Technology Data Exchange (ETDEWEB)

    Leclercq, L., E-mail: ludivine.leclercq@latmos.ipsl.fr [LATMOS/IPSL, UVSQ Université Paris-Saclay, UPMC Univ. Paris 06, CNRS, Guyancourt (France); Modolo, R., E-mail: ronan.modolo@latmos.ipsl.fr [LATMOS/IPSL, UVSQ Université Paris-Saclay, UPMC Univ. Paris 06, CNRS, Guyancourt (France); Leblanc, F. [LATMOS/IPSL, UPMC Univ. Paris 06 Sorbonne Universités, UVSQ, CNRS, Paris (France); Hess, S. [ONERA, Toulouse (France); Mancini, M. [LUTH, Observatoire Paris-Meudon (France)

    2016-03-15

    We present a new method to exploit multiple refinement levels within a 3D parallel hybrid model, developed to study planet–plasma interactions. This model is based on the hybrid formalism: ions are kinetically treated whereas electrons are considered as a inertia-less fluid. Generally, ions are represented by numerical particles whose size equals the volume of the cells. Particles that leave a coarse grid subsequently entering a refined region are split into particles whose volume corresponds to the volume of the refined cells. The number of refined particles created from a coarse particle depends on the grid refinement rate. In order to conserve velocity distribution functions and to avoid calculations of average velocities, particles are not coalesced. Moreover, to ensure the constancy of particles' shape function sizes, the hybrid method is adapted to allow refined particles to move within a coarse region. Another innovation of this approach is the method developed to compute grid moments at interfaces between two refinement levels. Indeed, the hybrid method is adapted to accurately account for the special grid structure at the interfaces, avoiding any overlapping grid considerations. Some fundamental test runs were performed to validate our approach (e.g. quiet plasma flow, Alfven wave propagation). Lastly, we also show a planetary application of the model, simulating the interaction between Jupiter's moon Ganymede and the Jovian plasma.

  18. Is cerebral oxygenation negatively affected by infusion of norepinephrine in healthy subjects?

    DEFF Research Database (Denmark)

    Brassard, P.; Seifert, T.; Secher, Niels H.

    2009-01-01

    BACKGROUND: Vasopressor agents are commonly used to increase mean arterial pressure (MAP) in order to secure a pressure gradient to perfuse vital organs. The influence of norepinephrine on cerebral oxygenation is not clear. The aim of this study was to evaluate the impact of the infusion of norep......BACKGROUND: Vasopressor agents are commonly used to increase mean arterial pressure (MAP) in order to secure a pressure gradient to perfuse vital organs. The influence of norepinephrine on cerebral oxygenation is not clear. The aim of this study was to evaluate the impact of the infusion...... of norepinephrine on cerebral oxygenation in healthy subjects. METHODS: Three doses of norepinephrine (0.05, 0.1, and 0.15 microg kg(-1) min(-1) for 20 min each) were infused in nine healthy subjects [six males; 26 (6) yr, mean (SD)]. MAP, cerebral oxygenation characterized by frontal lobe oxygenation (Sc(O2...... infused at 0.1 microg kg(-1) min(-1) [Sc(O2): 78 (75-94) to 69 (61-83)%; P

  19. Resin infusion of large composite structures modeling and manufacturing process

    Energy Technology Data Exchange (ETDEWEB)

    Loos, A.C. [Michigan State Univ., Dept. of Mechanical Engineering, East Lansing, MI (United States)

    2006-07-01

    The resin infusion processes resin transfer molding (RTM), resin film infusion (RFI) and vacuum assisted resin transfer molding (VARTM) are cost effective techniques for the fabrication of complex shaped composite structures. The dry fibrous preform is placed in the mold, consolidated, resin impregnated and cured in a single step process. The fibrous performs are often constructed near net shape using highly automated textile processes such as knitting, weaving and braiding. In this paper, the infusion processes RTM, RFI and VARTM are discussed along with the advantages of each technique compared with traditional composite fabrication methods such as prepreg tape lay up and autoclave cure. The large number of processing variables and the complex material behavior during infiltration and cure make experimental optimization of the infusion processes costly and inefficient. Numerical models have been developed which can be used to simulate the resin infusion processes. The model formulation and solution procedures for the VARTM process are presented. A VARTM process simulation of a carbon fiber preform was presented to demonstrate the type of information that can be generated by the model and to compare the model predictions with experimental measurements. Overall, the predicted flow front positions, resin pressures and preform thicknesses agree well with the measured values. The results of the simulation show the potential cost and performance benefits that can be realized by using a simulation model as part of the development process. (au)

  20. Convergence of hybrid methods for solving non-linear partial ...

    African Journals Online (AJOL)

    This paper is concerned with the numerical solution and convergence analysis of non-linear partial differential equations using a hybrid method. The solution technique involves discretizing the non-linear system of PDE to obtain a corresponding non-linear system of algebraic difference equations to be solved at each time ...

  1. Simultaneous infusion of glutamine and branched-chain amino acids (BCAA) to septic rats does not have more favorable effect on protein synthesis in muscle, liver, and small intestine than separate infusions.

    Science.gov (United States)

    Holecek, Milan; Muthny, Tomas; Kovarik, Miroslav; Sispera, Ludek

    2006-01-01

    Glutamine and branched-chain amino acids (BCAA; valine, leucine, and isoleucine) are used as nutrition supplements in the treatment of proteocatabolic illness. We hypothesized that simultaneous administration of BCAA and glutamine affects protein metabolism more significantly than separate administration. In the present study, we evaluated their effect on protein synthesis in skeletal muscle, liver, and jejunum of septic rats. Twenty-four hours after induction of sepsis by subcutaneous injection of turpentine, the rats were infused for 6 hours with 5 mL of 1.75% glutamine, 1.75% BCAA, 1.75% glutamine+BCAA, or saline solution. The control group consisted of intact rats infused with saline. Protein synthesis was measured at the end of infusion by a "flooding method" with [3,4,5-(3)H]phenylalanine. In turpentine-treated animals, we observed a decrease in glutamine concentration in blood plasma and skeletal muscle, a decrease in BCAA concentration in liver and jejunum, and a decrease in protein synthesis in all tissues. Glutamine or glutamine+BCAA infusion increased glutamine concentration in plasma and muscle and stimulated protein synthesis in the liver. The BCAA infusion enhanced concentrations of BCAA in plasma and tissues, but the effect of BCAA on protein synthesis was insignificant. Synergistic effect of simultaneous infusion of glutamine and BCAA on protein synthesis was not observed. We conclude that glutamine infusion to rats with septic injury may significantly improve impaired protein synthesis in the liver and that there is no synergistic effect of glutamine and BCAA infusion on protein synthesis in skeletal muscle, liver, and jejunum.

  2. Does overnight normalization of plasma glucose by insulin infusion affect assessment of glucose metabolism in Type 2 diabetes?

    DEFF Research Database (Denmark)

    Staehr, P; Højlund, Kurt; Hother-Nielsen, O

    2003-01-01

    AIMS: In order to perform euglycaemic clamp studies in Type 2 diabetic patients, plasma glucose must be reduced to normal levels. This can be done either (i) acutely during the clamp study using high-dose insulin infusion, or (ii) slowly overnight preceding the clamp study using a low-dose insulin...... infusion. We assessed whether the choice of either of these methods to obtain euglycaemia biases subsequent assessment of glucose metabolism and insulin action. METHODS: We studied seven obese Type 2 diabetic patients twice: once with (+ ON) and once without (- ON) prior overnight insulin infusion. Glucose...... turnover rates were quantified by adjusted primed-constant 3-3H-glucose infusions, and insulin action was assessed in 4-h euglycaemic, hyperinsulinaemic (40 mU m-2 min-1) clamp studies using labelled glucose infusates (Hot-GINF). RESULTS: Basal plasma glucose levels (mean +/- sd) were 5.5 +/- 0.5 and 10...

  3. Irrigation method does not affect wild bee pollinators of hybrid sunflower

    Directory of Open Access Journals (Sweden)

    Hillary Sardiñas

    2016-09-01

    Full Text Available Irrigation method has the potential to directly or indirectly influence populations of wild bee crop pollinators nesting and foraging in irrigated crop fields. The majority of wild bee species nest in the ground, and their nests may be susceptible to flooding. In addition, their pollination of crops can be influenced by nectar quality and quantity, which are related to water availability. To determine whether different irrigation methods affect crop pollinators, we compared the number of ground-nesting bees nesting and foraging in drip- and furrow-irrigated hybrid sunflower fields in the Sacramento Valley. We found that irrigation method did not impact wild bee nesting rates or foraging bee abundance or bee species richness. These findings suggest that changing from furrow irrigation to drip irrigation to conserve water likely will not alter hybrid sunflower crop pollination.

  4. Hybrid immersed boundary method for airfoils with a trailing-edge flap

    DEFF Research Database (Denmark)

    Zhu, Wei Jun; Behrens, Tim; Shen, Wen Zhong

    2013-01-01

    In this paper, a hybrid immersed boundary technique has been developed for simulating turbulent flows past airfoils with moving trailing-edge flaps. Over the main fixed part of the airfoil, the equations are solved using a standard body-fitted finite volume technique, whereas the moving trailing......-edge flap is simulated using the immersed boundary method on a curvilinear mesh. An existing in-house-developed flow solver is employed to solve the incompressible Reynolds-Averaged Navier-Stokes equations together with the k-ω turbulence model. To achieve consistent wall boundary conditions at the immersed...... boundaries the k-ωturbulence model is modified and adapted to the local conditions associated with the immersed boundary method. The obtained results show that the hybrid approach is an efficient and accurate method for solving turbulent flows past airfoils with a trailing-edge flap and that flow control...

  5. Weekly ascorbic acid infusion in castration-resistant prostate cancer patients

    DEFF Research Database (Denmark)

    Nielsen, Torben K.; Højgaard, Martin; Andersen, Jon T.

    2017-01-01

    of this treatment.  Methods: This non-comparative, single-center, phase II trial included patients with chemotherapy-naïve, metastatic castration-resistant prostate cancer (mCRPC) from an outpatient clinic to evaluate the efficacy and safety of IV AA therapy. Patients received weekly infusions of AA (week 1, 5 g...... μg/L was recorded at week 12. Among the secondary endpoints, no signs of disease remission were observed. In total, 53 adverse events (AEs) were recorded. Eleven were graded as "serious". Three AEs were directly related to AA, and all of which were related to fluid load.  Conclusions: Infusion...

  6. Decentralized Method for Load Sharing and Power Management in a Hybrid Single/Three-Phase-Islanded Microgrid Consisting of Hybrid Source PV/Battery Units

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Guerrero, Josep M.

    2017-01-01

    This paper proposes a new decentralized power management and load sharing method for a photovoltaic based, hybrid single/three-phase islanded microgrid consisting of various PV units, battery units and hybrid PV/battery units. The proposed method is not limited to the systems with separate PV...... in different load, PV generation and battery conditions is validated experimentally in a microgrid lab prototype consisted of one three-phase unit and two single-phase units....

  7. Hybrid transfer-matrix FDTD method for layered periodic structures.

    Science.gov (United States)

    Deinega, Alexei; Belousov, Sergei; Valuev, Ilya

    2009-03-15

    A hybrid transfer-matrix finite-difference time-domain (FDTD) method is proposed for modeling the optical properties of finite-width planar periodic structures. This method can also be applied for calculation of the photonic bands in infinite photonic crystals. We describe the procedure of evaluating the transfer-matrix elements by a special numerical FDTD simulation. The accuracy of the new method is tested by comparing computed transmission spectra of a 32-layered photonic crystal composed of spherical or ellipsoidal scatterers with the results of direct FDTD and layer-multiple-scattering calculations.

  8. In vivo tracking of 111In-oxine labeled mesenchymal stem cells following infusion in patients with advanced cirrhosis

    International Nuclear Information System (INIS)

    Gholamrezanezhad, Ali; Mirpour, Sahar; Bagheri, Mohammad; Mohamadnejad, Mehdi; Alimoghaddam, Kamran; Abdolahzadeh, Leila; Saghari, Mohsen; Malekzadeh, Reza

    2011-01-01

    Background: Several animal and few human studies suggest the beneficial role of bone marrow mesenchymal stem cells (MSCs) in liver cirrhosis. However, little is known about the fate of MSCs after infusion in cirrhotic patients. We evaluated stem cell biodistribution after peripheral infusion of MSCs in four cirrhotic patients. Methods: After three passages of MSCs, the patients received a total of 250-400x10 6 cells, of which only 50% of the cells were labeled. Specific activities of 0.21-0.67 MBq/10 6 cells were maintained for the injected labeled MSCs. Planar whole-body acquisitions (anterior/posterior projections) were acquired immediately following infusion as well as at 2 h, 4 h, 6 h, 24 h, 48 h, 7th and 10th days after cell infusion. Results: After intravenous infusion, the radioactivity was first observed to accumulate in the lungs. During the following hours to days, the radioactivity gradually increased in the liver and spleen, with spleen uptake exceeding that in the liver in all patients. Region-of-interest analysis showed that the percentage of cells homing to the liver (following decay and background corrections and geometric mean calculation) increased from 0.0%-2.8% at immediately post-infusion images to 13.0-17.4% in 10th-day post-infusion. Similarly, the residual activities in the spleen increased from 2.0%-10.2% at immediately post-infusion images to 30.1%-42.2% in 10th-day post-infusion. During the same period, the residual activities in the lungs decreased from 27.0-33.5% to 2.0-5.4%. Conclusion: The infusion of MSCs labeled with 111 In-oxine through a peripheral vein is safe in cirrhosis. Cell labeling with 111 In-oxine is a suitable method for tracking MSC distribution after infusion.

  9. Thermal Properties of Hybrid Carbon Nanotube/Carbon Fiber Polymer

    Science.gov (United States)

    Kang, Jin Ho; Cano, Roberto J.; Luong, Hoa; Ratcliffe, James G.; Grimsley, Brian W.; Siochi, Emilie J.

    2016-01-01

    Carbon fiber reinforced polymer (CFRP) composites possess many advantages for aircraft structures over conventional aluminum alloys: light weight, higher strength- and stiffness-to-weight ratio, and low life-cycle maintenance costs. However, the relatively low thermal and electrical conductivities of CFRP composites are deficient in providing structural safety under certain operational conditions such as lightning strikes. One possible solution to these issues is to interleave carbon nanotube (CNT) sheets between conventional carbon fiber (CF) composite layers. However, the thermal and electrical properties of the orthotropic hybrid CNT/CF composites have not been fully understood. In this study, hybrid CNT/CF polymer composites were fabricated by interleaving layers of CNT sheets with Hexcel (Registered Trademark) IM7/8852 prepreg. The CNT sheets were infused with a 5% solution of a compatible epoxy resin prior to composite fabrication. Orthotropic thermal and electrical conductivities of the hybrid polymer composites were evaluated. The interleaved CNT sheets improved the in-plane thermal conductivity of the hybrid composite laminates by about 400% and the electrical conductivity by about 3 orders of magnitude.

  10. Current use of intraosseous infusion in Danish emergency departments

    DEFF Research Database (Denmark)

    Molin, Rune; Hallas, Peter; Brabrand, Mikkel

    2010-01-01

    BACKGROUND: Intraosseous infusion (IOI) is recommended when intravenous access cannot be readily established in both pediatric and adult resuscitation. We evaluated the current use of IOI in Danish emergency departments (EDs). METHODS: An online questionnaire was e-mailed to the Heads of Department...

  11. Continuous intraperitoneal insulin infusion in patients with 'brittle' diabetes

    DEFF Research Database (Denmark)

    DeVries, J H; Eskes, S A; Snoek, Frank J

    2002-01-01

    AIMS: To evaluate the effects of continuous intraperitoneal insulin infusion (CIPII) using implantable pumps on glycaemic control and duration of hospital stay in poorly controlled 'brittle' Dutch diabetes patients, and to assess their current quality of life. METHODS: Thirty-three patients were...

  12. Effect of elevated temperature on the tensile strength of Napier/glass-epoxy hybrid reinforced composites

    Science.gov (United States)

    Ridzuan, M. J. M.; Majid, M. S. Abdul; Afendi, M.; Firdaus, A. Z. Ahmad; Azduwin, K.

    2017-11-01

    The effects of elevated temperature on the tensile strength of Napier/glass-epoxy hybrid reinforced composites and its morphology of fractured surfaces are discussed. Napier/glass-epoxy hybrid reinforced composites were fabricated by using vacuum infusion method by arranging Napier fibres in between sheets of woven glass fibres. Napier and glass fibres were laminated with estimated volume ratios were 24 and 6 vol. %, respectively. The epoxy resin was used as matrix estimated to 70 vol. %. Specimens were tested to failure under tension at a cross-head speed of 1 mm/min using Universal Testing Machine (Instron) with a load cell 100 kN at four different temperatures of RT, 40°C, 60°C and 80°C. The morphology of fractured surface of hybrid composites was investigated by field emission scanning electron microscopy. The result shows reduction in tensile strength at elevated temperatures. The increase in the temperature activates the process of diffusion, and generates critical stresses which cause the damage at first-ply or at the centre of the hybrid plate, as a result lower the tensile strength. The observation of FESEM images indicates that the fracture mode is of evolution of localized damage, from fibre/matrix debonding, matric cracking, delamination and fibre breakage.

  13. A hybrid method combining the Time-Domain Method of Moments, the Time-Domain Uniform Theory of Diffraction and the FDTD

    Directory of Open Access Journals (Sweden)

    A. Becker

    2007-06-01

    Full Text Available In this paper a hybrid method combining the Time-Domain Method of Moments (TD-MoM, the Time-Domain Uniform Theory of Diffraction (TD-UTD and the Finite-Difference Time-Domain Method (FDTD is presented. When applying this new hybrid method, thin-wire antennas are modeled with the TD-MoM, inhomogeneous bodies are modelled with the FDTD and large perfectly conducting plates are modelled with the TD-UTD. All inhomogeneous bodies are enclosed in a so-called FDTD-volume and the thin-wire antennas can be embedded into this volume or can lie outside. The latter avoids the simulation of white space between antennas and inhomogeneous bodies. If the antennas are positioned into the FDTD-volume, their discretization does not need to agree with the grid of the FDTD. By using the TD-UTD large perfectly conducting plates can be considered efficiently in the solution-procedure. Thus this hybrid method allows time-domain simulations of problems including very different classes of objects, applying the respective most appropriate numerical techniques to every object.

  14. Development and validation of a UPLC-MS/MS method to monitor cephapirin excretion in dairy cows following intramammary infusion.

    Directory of Open Access Journals (Sweden)

    Partha Ray

    Full Text Available Cephapirin, a cephalosporin antibiotic, is used by the majority of dairy farms in the US. Fecal and urinary excretion of cephapirin could introduce this compound into the environment when manure is land applied as fertilizer, and may cause development of bacterial resistance to antibiotics critical for human health. The environmental loading of cephapirin by the livestock industry remains un-assessed, largely due to a lack of appropriate analytical methods. Therefore, this study aimed to develop and validate a cephapirin quantification method to capture the temporal pattern of cephapirin excretion in dairy cows following intramammary infusion. The method includes an extraction with phosphate buffer and methanol, solid-phase extraction (SPE clean-up, and quantification using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS. The LOQ values of the developed method were 4.02 µg kg(-1 and 0.96 µg L(-1 for feces and urine, respectively. This robust method recovered >60% and >80% cephapirin from spiked blank fecal and urine samples, respectively, with acceptable intra- and inter-day variation (<10%. Using this method, we detected trace amounts (µg kg(-1 of cephapirin in dairy cow feces, and cephapirin in urine was detected at very high concentrations (133 to 480 µg L(-1. Cephapirin was primarily excreted via urine and its urinary excretion was influenced by day (P = 0.03. Peak excretion (2.69 mg was on day 1 following intramammary infusion and decreased sharply thereafter (0.19, 0.19, 0.08, and 0.17 mg on day 2, 3, 4, and 5, respectively reflecting a quadratic pattern of excretion (Quadratic: P = 0.03. The described method for quantification of cephapirin in bovine feces and urine is sensitive, accurate, and robust and allowed to monitor the pattern of cephapirin excretion in dairy cows. This data will help develop manure segregation and treatment methods to minimize the risk of antibiotic loading to the environment from

  15. A modeling method of semiconductor fabrication flows with extended knowledge hybrid Petri nets

    Institute of Scientific and Technical Information of China (English)

    Zhou Binghai; Jiang Shuyu; Wang Shijin; Wu bin

    2008-01-01

    A modeling method of extended knowledge hybrid Petri nets (EKHPNs), incorporating object-oriented methods into hybrid Petri nets (HPNs), was presented and used for the representation and modeling of semiconductor wafer fabrication flows. To model the discrete and continuous parts of a complex semiconductor wafer fabrication flow, the HPNs were introduced into the EKHPNs. Object-oriented methods were combined into the EKHPNs for coping with the complexity of the fabrication flow. Knowledge annotations were introduced to solve input and output conflicts of the EKHPNs.Finally, to demonstrate the validity of the EKHPN method, a real semiconductor wafer fabrication case was used to illustrate the modeling procedure. The modeling results indicate that the proposed method can be used to model a complex semiconductor wafer fabrication flow expediently.

  16. Red tea leaves infusion as a reducing and stabilizing agent in silver nanoparticles synthesis

    Science.gov (United States)

    Pluta, K.; Tryba, A. M.; Malina, D.; Sobczak-Kupiec, A.

    2017-12-01

    Due to the unique properties of silver nanoparticles there is growing interest in their applications. Current trends in nanotechnology are focused on developing a new technique to synthesize nanoparticles using biological methods associated with the use of plant extracts, fungi, bacteria or essential oils. These methods are a promising alternative to conventional approaches which can minimize the use of hazardous substances. The silver nanoparticles synthesis using red tea infusion as a reducing and stabilizing agent and their characteristics have been described. Total antioxidant capacity using DPPH radical and total content of phenolic compounds by Folin-Ciocalteau method were measured in tea infusion. Synthesis of silver nanoparticles was carried out using chemical reduction at various temperatures. Furthermore, the effect of tea infusion volume added to reaction mixture on nanoparticles’ properties was investigated. Finally, nanosilver suspensions were characterized by UV-vis spectrophotometer, dynamic light scattering (DLS) scanning electron microscope (SEM) and transmission electron microscope (TEM). Moreover, phytotoxicity of silver nanoparticles was determined using Phytotestkit microbiotest.

  17. The History of Target-Controlled Infusion

    NARCIS (Netherlands)

    Struys, Michel M. R. F.; De Smet, Tom; Glen, John (Iain) B.; Vereecke, Hugo E. M.; Absalom, Anthony R.; Schnider, Thomas W.

    Target-controlled infusion (TCI) is a technique of infusing IV drugs to achieve a user-defined predicted (target) drug concentration in a specific body compartment or tissue of interest. In this review, we describe the pharmacokinetic principles of TCI, the development of TCI systems, and technical

  18. Extension of a hybrid particle-continuum method for a mixture of chemical species

    Science.gov (United States)

    Verhoff, Ashley M.; Boyd, Iain D.

    2012-11-01

    Due to the physical accuracy and numerical efficiency achieved by analyzing transitional, hypersonic flow fields with hybrid particle-continuum methods, this paper describes a Modular Particle-Continuum (MPC) method and its extension to include multiple chemical species. Considerations that are specific to a hybrid approach for simulating gas mixtures are addressed, including a discussion of the Chapman-Enskog velocity distribution function (VDF) for near-equilibrium flows, and consistent viscosity models for the individual CFD and DSMC modules of the MPC method. Representative results for a hypersonic blunt-body flow are then presented, where the flow field properties, surface properties, and computational performance are compared for simulations employing full CFD, full DSMC, and the MPC method.

  19. A DNA microarray-based methylation-sensitive (MS)-AFLP hybridization method for genetic and epigenetic analyses.

    Science.gov (United States)

    Yamamoto, F; Yamamoto, M

    2004-07-01

    We previously developed a PCR-based DNA fingerprinting technique named the Methylation Sensitive (MS)-AFLP method, which permits comparative genome-wide scanning of methylation status with a manageable number of fingerprinting experiments. The technique uses the methylation sensitive restriction enzyme NotI in the context of the existing Amplified Fragment Length Polymorphism (AFLP) method. Here we report the successful conversion of this gel electrophoresis-based DNA fingerprinting technique into a DNA microarray hybridization technique (DNA Microarray MS-AFLP). By performing a total of 30 (15 x 2 reciprocal labeling) DNA Microarray MS-AFLP hybridization experiments on genomic DNA from two breast and three prostate cancer cell lines in all pairwise combinations, and Southern hybridization experiments using more than 100 different probes, we have demonstrated that the DNA Microarray MS-AFLP is a reliable method for genetic and epigenetic analyses. No statistically significant differences were observed in the number of differences between the breast-prostate hybridization experiments and the breast-breast or prostate-prostate comparisons.

  20. The structure and control method of hybrid power source for electric vehicle

    International Nuclear Information System (INIS)

    Li, Maobing; Xu, Hui; Li, Weimin; Liu, Yin; Li, Fade; Hu, Yue; Liu, Li

    2016-01-01

    In this paper, an electric vehicle powertrain configuration is presented, which the lithium-ion battery integrated with ultracapacitors is developed as the hybrid power system to improve the transient performance of an electric vehicle, and to decrease the damage to the battery pack. In the proposed system, a bidirectional direct current/direct current converter is used to couple the ultracapacitors bank to the main battery pack. The energy management strategy based on fuzzy logic for hybrid power system has been proposed to promote the performance of energy flow in the electric vehicle. The experiment results in urban driving cycles show remarkable advantages of the proposed hybrid system configuration and energy management strategy. About 30% of the battery capacity energy is saved while using the hybrid power source. Besides, the voltage and current curves of battery become smoother than that with the single power. - Highlights: • A hybrid power source electric vehicle powertrain configuration is presented. • The energy management strategy based on fuzzy logic is proposed. • The experiment results show remarkable advantages of the configuration and method.

  1. 99Tcm-MIBI imaging with liposomal prostaglandin E1 infusion to detect viable myocardium in post-myocardial infarction patients

    International Nuclear Information System (INIS)

    Zheng Yong; Cai Hongbin; Miao Weibing; Lin Jun; Pan Runyang; Lin Haoxue

    2007-01-01

    Objective: The pharmacological efficiencies of liposomal prostaglandin E 1 (Lipo-PGE 1 ) infusion and nitrate infusion on 99 Tc m -methoxyisobutylisonitrile (MIBI) imaging detection of viable myocardium in post-myocardial infarction (MI) patients were compared in the current study. Methods: Thirty-two patients with MI underwent 99 Tc m -MIBI imaging at rest, nitrate infusion and Lipo-PGE 1 infusion respectively. The semi-quantitative analysis of 99 Tc m -MIBI imaging was carried out in 16 segments over each left ventricle. Results: Abnormal 99 Tc m -MIBI distribution in 216 segments (42.2%) at rest, 178 segments (34.8%) at nitrate infusion, and 184 segments (35.9%) at Lipo-PGE 1 infusion were identified. Among the 216 abnormal segments at rest, 89 (41.2%) and 81 (37.5%) were found improved after nitrate infusion and Lipo-PGE 1 infusion respectively. Detecting viable myocardium with Lipo-PGE 1 infusion imaging was accordant with that of nitrate infusion imaging in 89.8% of the cases. The mean uptake scores of abnormal segments at rest, nitrate infusion, and Lipo-PGE 1 infusion were 15.3 ± 3.3, 10.5 ± 1.4 (P 1 infusion imaging can be used for detection of viable myocardium in patients with MI. (authors)

  2. Low-dose factor VIII infusion in Chinese adult haemophilia A patients: pharmacokinetics evidence that daily infusion results in higher trough level than with every-other-day infusion with similar factor VIII consumption.

    Science.gov (United States)

    Hua, B; Lee, A; Fan, L; Li, K; Zhang, Y; Poon, M-C; Zhao, Y

    2017-05-01

    Pharmacokinetics (PK) modelling suggests improvement of trough levels are achieved by using more frequent infusion strategy. However, no clinical study data exists to confirm or quantify improvement in trough level, particularly for low-dose prophylaxis in patients with haemophilia A. To provide evidence that low dose daily (ED) prophylaxis can increase trough levels without increasing FVIII consumption compared to every-other-day (EOD) infusion. A cross-over study on 5 IU kg -1 FVIII daily vs. 10 IU kg -1 EOD infusions, each for 14 days was conducted at the PUMCH-HTC. On the ED schedule, trough (immediate prior to infusion), and peak FVIII:C levels (30 min after infusion) were measured on days 1-5; and trough levels alone on days 7, 9, 11 and 13. For the EOD schedule, troughs, peaks and 4-h postinfusion were measured on day 1; troughs and peaks on days 3, 5, and 7; troughs alone on days 9, 11 and 13 and 24-h postinfusion on days 2, 4 and 6. FVIII inhibitors were assessed on days 0 and 14 during both infusion schedules. Six patients were enrolled. PK evidence showed that daily prophylaxis achieved higher (~2 times) steady-state FVIII trough levels compared to EOD with the same total factor consumption. The daily prophylaxis had good acceptability among patients and reduced chronic pain in the joints in some patients. Our PK study shows low-dose factor VIII daily infusion results in higher trough level than with EOD infusion with similar factor VIII consumption in Chinese adult haemophilia A patients. © 2017 John Wiley & Sons Ltd.

  3. Comparison of kDNA PCR-hybridization assay with three PCR methods for canines visceral Leishmaniasis diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Pilatti, Marcia M.; Andrade, Antero S.R. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)], e-mail: marciapilatti@yahoo.com.br, e-mail: antero@cdtn.br; Ferreira, Sidney A. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Parasitologia], e-mail: saninoalmeida@gmail.com

    2009-07-01

    The sensitivity of the kDNA PCR-Hybridization assay, which uses radioactive DNA probes (labeled with {sup 32}P), was compared with three conventional PCR methods used for canine visceral leishmaniasis diagnosis. All PCR methods had two steps: a first amplification followed by hybridization or by a new amplification (nested or semi nested). Two methods (kDNA PCR-Hybridization and kDNA snPCR) used primers addressed to kinetoplast minicircles and the other two methods to the coding (LnPCR) and intergenic noncoding regions (ITS-1 nPCR) of the ribosomal rRNA genes. The comparison was accomplished in two groups of 23 infected dogs using samples collected by the conjunctival swab procedure. In the Group 1 the DNA was extracted from cotton swabs by phenol-chloroform and in Group 2 by boiling. The most efficient PCR methods in the Group 1 were those based on kDNA targets. The kDNA PCR-Hybridization was able to detect parasites in 22/23 dogs (95.6%) and in 40/46 samples (86.9%). The kDNA snPCR was positive for 21/23 dogs (91.3%) and for 40/46 samples (86.9%). The positivities of the kDNA based methods were significantly higher than the positivities verified for the methods based on ribosomal rRNA genes (p<0.05). In the Group 2 the kDNA PCR- Hybridization showed a better performance detecting parasites in 18/23 dogs (78.3%) and in 31/46 samples (67.4%), significantly higher than the other three methods (p<0.05). The higher sensitivity of the minicircle kDNA based assays reported by others was confirmed in this study and kDNA PCR-Hybridization showed the best sensitivity among the assays evaluated. (author)

  4. Comparison of kDNA PCR-hybridization assay with three PCR methods for canines visceral Leishmaniasis diagnosis

    International Nuclear Information System (INIS)

    Pilatti, Marcia M.; Andrade, Antero S.R.; Ferreira, Sidney A.

    2009-01-01

    The sensitivity of the kDNA PCR-Hybridization assay, which uses radioactive DNA probes (labeled with 32 P), was compared with three conventional PCR methods used for canine visceral leishmaniasis diagnosis. All PCR methods had two steps: a first amplification followed by hybridization or by a new amplification (nested or semi nested). Two methods (kDNA PCR-Hybridization and kDNA snPCR) used primers addressed to kinetoplast minicircles and the other two methods to the coding (LnPCR) and intergenic noncoding regions (ITS-1 nPCR) of the ribosomal rRNA genes. The comparison was accomplished in two groups of 23 infected dogs using samples collected by the conjunctival swab procedure. In the Group 1 the DNA was extracted from cotton swabs by phenol-chloroform and in Group 2 by boiling. The most efficient PCR methods in the Group 1 were those based on kDNA targets. The kDNA PCR-Hybridization was able to detect parasites in 22/23 dogs (95.6%) and in 40/46 samples (86.9%). The kDNA snPCR was positive for 21/23 dogs (91.3%) and for 40/46 samples (86.9%). The positivities of the kDNA based methods were significantly higher than the positivities verified for the methods based on ribosomal rRNA genes (p<0.05). In the Group 2 the kDNA PCR- Hybridization showed a better performance detecting parasites in 18/23 dogs (78.3%) and in 31/46 samples (67.4%), significantly higher than the other three methods (p<0.05). The higher sensitivity of the minicircle kDNA based assays reported by others was confirmed in this study and kDNA PCR-Hybridization showed the best sensitivity among the assays evaluated. (author)

  5. An experimental study on the influence of infusion speed on the early mechanism of embolic effect of arterially infused absolute Ethanol in the rat

    International Nuclear Information System (INIS)

    Han, Joon Koo; Kim, Woo Ho; Lee, Byung Hee; Park, Kil Sun; Park, Jae Hyung; Kim, Chu Wan; Han, Man Chung

    1990-01-01

    In order to clarify the early mechanism of action of the tissue necrosis induced by intraarterially infused absolute ethanol, abdominal aortography and histopathologic examination after absolute ethanol infusion into aorta at fast (0.4ml/sec) and slow speed (0.04ml/sec) were performed on 22 rats (2 controls, 7 in fast infusion group, 7 in slow infusion group, 3 in fast and 3 in slow infusion groups during aorta compression, respectively). Histopathologic features under the light and scanning electron microscope were correlated with the angiographic findings within 30 minutes after ethanol infusion. The results are as follows : 1. In fast infusion group, histopathologic examination of the kidney showed severe glomerular and tubular damage. Extensive damage on endothelial and medial layer was noted in arteries, and fresh thrombi originated from the damaged arterial wall were seen. 2. Angiographic findings in the fast infusion group were luminal irregularity and early obstruction of large arteries. And circulation time was prolonged. 3. In slow infusion group, histopathologic examination of the kidney showed focal area of severe glomerular and tubular damage on relatively normal background. Endothelial and muscular damage was noted in arteries, but the degree of the damage was less severe than that of the fast infusion group. 4. Angiographic findings in the slow infusion group were focal perfusion defect of the kidney, delayed circulation time, and mild luminal irregularity, but obstruction of the major arteries was not seen

  6. The effects of incisional bupivacaine infusions on postoperative ...

    African Journals Online (AJOL)

    Abstract. Background: The aim of this study was to determine opioid requirements and pain intensity scores in patients after a total abdominal hysterectomy (TAH) administered with a bupivacaine infusion for a 30-hour period, and then to compare the data with that of a control group. Method: This was a prospective, parallel, ...

  7. Infusing Systems Thinking into Career Counseling

    Science.gov (United States)

    Ryan, Charles W.; Tomlin, James H.

    2010-01-01

    This study examined the role of career counselors in infusing systems thinking into occupational advising. The authors conducted a qualitative review and analysis of selected literature on systems thinking and analyzed trends for adaptation to career counseling practice. This analysis suggests that career counselors need to infuse systems…

  8. Solving Optimal Control Problem of Monodomain Model Using Hybrid Conjugate Gradient Methods

    Directory of Open Access Journals (Sweden)

    Kin Wei Ng

    2012-01-01

    Full Text Available We present the numerical solutions for the PDE-constrained optimization problem arising in cardiac electrophysiology, that is, the optimal control problem of monodomain model. The optimal control problem of monodomain model is a nonlinear optimization problem that is constrained by the monodomain model. The monodomain model consists of a parabolic partial differential equation coupled to a system of nonlinear ordinary differential equations, which has been widely used for simulating cardiac electrical activity. Our control objective is to dampen the excitation wavefront using optimal applied extracellular current. Two hybrid conjugate gradient methods are employed for computing the optimal applied extracellular current, namely, the Hestenes-Stiefel-Dai-Yuan (HS-DY method and the Liu-Storey-Conjugate-Descent (LS-CD method. Our experiment results show that the excitation wavefronts are successfully dampened out when these methods are used. Our experiment results also show that the hybrid conjugate gradient methods are superior to the classical conjugate gradient methods when Armijo line search is used.

  9. Hybrid modelling framework by using mathematics-based and information-based methods

    International Nuclear Information System (INIS)

    Ghaboussi, J; Kim, J; Elnashai, A

    2010-01-01

    Mathematics-based computational mechanics involves idealization in going from the observed behaviour of a system into mathematical equations representing the underlying mechanics of that behaviour. Idealization may lead mathematical models that exclude certain aspects of the complex behaviour that may be significant. An alternative approach is data-centric modelling that constitutes a fundamental shift from mathematical equations to data that contain the required information about the underlying mechanics. However, purely data-centric methods often fail for infrequent events and large state changes. In this article, a new hybrid modelling framework is proposed to improve accuracy in simulation of real-world systems. In the hybrid framework, a mathematical model is complemented by information-based components. The role of informational components is to model aspects which the mathematical model leaves out. The missing aspects are extracted and identified through Autoprogressive Algorithms. The proposed hybrid modelling framework has a wide range of potential applications for natural and engineered systems. The potential of the hybrid methodology is illustrated through modelling highly pinched hysteretic behaviour of beam-to-column connections in steel frames.

  10. Is continuous infusion of imipenem always the best choice?

    Science.gov (United States)

    Suchánková, Hana; Lipš, Michal; Urbánek, Karel; Neely, Michael N; Strojil, Jan

    2017-03-01

    Monte Carlo simulations allow prediction and comparison of concentration-time profiles arising from different dosing regimens in a defined population, provided a population pharmacokinetic model has been established. The aims of this study were to evaluate the population pharmacokinetics of imipenem in critically ill patients with hospital-acquired pneumonia (HAP) and to assess the probability of target attainment (PTA) and cumulative fraction of response (CFR) using EUCAST data. A two-compartment model based on a data set of 19 subjects was employed. Various dosage regimens at 0.5-h and 3-h infusion rates and as continuous infusion were evaluated against the pharmacodynamic targets of 20%fT >MIC , 40%fT >MIC and 100%fT >MIC . For the target of 40%fT >MIC , all 0.5-h infusion regimens achieved optimal exposures (CFR ≥ 90%) against Escherichia coli and Staphylococcus aureus, with nearly optimal exposure against Klebsiella pneumoniae (CFR ≥ 89.4%). The 3-h infusions and continuous infusion exceeded 97% CFR against all pathogens with the exception of Pseudomonas aeruginosa and Acinetobacter spp., where the maximum CFRs were 85.5% and 88.4%, respectively. For the 100%fT >MIC target, only continuous infusion was associated with nearly optimal exposures. Higher PTAs for the targets of 40%fT >MIC and 100%fT >MIC were achieved with 3-h infusions and continuous infusion in comparison with 0.5-h infusions; however, continuous infusion carries a risk of not reaching the MIC of less susceptible pathogens in a higher proportion of patients. In critically ill patients with HAP with risk factors for Gram-negative non-fermenting bacteria, maximum doses administered as extended infusions may be necessary. Copyright © 2017 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.

  11. A Novel Method for Rapid Hybridization of DNA to a Solid Support

    Science.gov (United States)

    Pettersson, Erik; Ahmadian, Afshin; Ståhl, Patrik L.

    2013-01-01

    Here we present a novel approach entitled Magnetic Forced Hybridization (MFH) that provides the means for efficient and direct hybridization of target nucleic acids to complementary probes immobilized on a glass surface in less than 15 seconds at ambient temperature. In addition, detection is carried out instantly since the beads become visible on the surface. The concept of MFH was tested for quality control of array manufacturing, and was combined with a multiplex competitive hybridization (MUCH) approach for typing of Human Papilloma Virus (HPV). Magnetic Forced Hybridization of bead-DNA constructs to a surface achieves a significant reduction in diagnostic testing time. In addition, readout of results by visual inspection of the unassisted eye eliminates the need for additional expensive instrumentation. The method uses the same set of beads throughout the whole process of manipulating and washing DNA constructs prior to detection, as in the actual detection step itself. PMID:23950946

  12. Hybrid ICA-Seed-Based Methods for fMRI Functional Connectivity Assessment: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Robert E. Kelly

    2010-01-01

    Full Text Available Brain functional connectivity (FC is often assessed from fMRI data using seed-based methods, such as those of detecting temporal correlation between a predefined region (seed and all other regions in the brain; or using multivariate methods, such as independent component analysis (ICA. ICA is a useful data-driven tool, but reproducibility issues complicate group inferences based on FC maps derived with ICA. These reproducibility issues can be circumvented with hybrid methods that use information from ICA-derived spatial maps as seeds to produce seed-based FC maps. We report results from five experiments to demonstrate the potential advantages of hybrid ICA-seed-based FC methods, comparing results from regressing fMRI data against task-related a priori time courses, with “back-reconstruction” from a group ICA, and with five hybrid ICA-seed-based FC methods: ROI-based with (1 single-voxel, (2 few-voxel, and (3 many-voxel seed; and dual-regression-based with (4 single ICA map and (5 multiple ICA map seed.

  13. Infusion phlebitis assessment measures: a systematic review

    OpenAIRE

    Ray-Barruel, Gillian; Polit, Denise F; Murfield, Jenny E; Rickard, Claire M

    2014-01-01

    Rationale, aims and objectives Phlebitis is a common and painful complication of peripheral intravenous cannulation. The aim of this review was to identify the measures used in infusion phlebitis assessment and evaluate evidence regarding their reliability, validity, responsiveness and feasibility. Method We conducted a systematic literature review of the Cochrane library, Ovid MEDLINE and EBSCO CINAHL until September 2013. All English-language studies (randomized controlled trials, prospecti...

  14. EIT image reconstruction based on a hybrid FE-EFG forward method and the complete-electrode model.

    Science.gov (United States)

    Hadinia, M; Jafari, R; Soleimani, M

    2016-06-01

    This paper presents the application of the hybrid finite element-element free Galerkin (FE-EFG) method for the forward and inverse problems of electrical impedance tomography (EIT). The proposed method is based on the complete electrode model. Finite element (FE) and element-free Galerkin (EFG) methods are accurate numerical techniques. However, the FE technique has meshing task problems and the EFG method is computationally expensive. In this paper, the hybrid FE-EFG method is applied to take both advantages of FE and EFG methods, the complete electrode model of the forward problem is solved, and an iterative regularized Gauss-Newton method is adopted to solve the inverse problem. The proposed method is applied to compute Jacobian in the inverse problem. Utilizing 2D circular homogenous models, the numerical results are validated with analytical and experimental results and the performance of the hybrid FE-EFG method compared with the FE method is illustrated. Results of image reconstruction are presented for a human chest experimental phantom.

  15. New hybrid frequency reuse method for packet loss minimization in LTE network.

    Science.gov (United States)

    Ali, Nora A; El-Dakroury, Mohamed A; El-Soudani, Magdi; ElSayed, Hany M; Daoud, Ramez M; Amer, Hassanein H

    2015-11-01

    This paper investigates the problem of inter-cell interference (ICI) in Long Term Evolution (LTE) mobile systems, which is one of the main problems that causes loss of packets between the base station and the mobile station. Recently, different frequency reuse methods, such as soft and fractional frequency reuse, have been introduced in order to mitigate this type of interference. In this paper, minimizing the packet loss between the base station and the mobile station is the main concern. Soft Frequency Reuse (SFR), which is the most popular frequency reuse method, is examined and the amount of packet loss is measured. In order to reduce packet loss, a new hybrid frequency reuse method is implemented. In this method, each cell occupies the same bandwidth of the SFR, but the total system bandwidth is greater than in SFR. This will provide the new method with a lot of new sub-carriers from the neighboring cells to reduce the ICI which represents a big problem in many applications and causes a lot of packets loss. It is found that the new hybrid frequency reuse method has noticeable improvement in the amount of packet loss compared to SFR method in the different frequency bands. Traffic congestion management in Intelligent Transportation system (ITS) is one of the important applications that is affected by the packet loss due to the large amount of traffic that is exchanged between the base station and the mobile node. Therefore, it is used as a studied application for the proposed frequency reuse method and the improvement in the amount of packet loss reached 49.4% in some frequency bands using the new hybrid frequency reuse method.

  16. Krypton 81m infusion studies. Chapter 18

    International Nuclear Information System (INIS)

    Kaplan, E.; Mayron, L.W.; Friedman, A.M.; Gindler, J.E.

    1978-01-01

    A technique is described to give a continuous, constant-rate, intravascular infusion of 81 Krsup(m). Modifications of earlier generators included production of sodium-free 81 Rb, the use of a solution of commercial sterile isotonic non-ionic 5% dextrose-in-water as an eluant, the incorporation of a constant-rate infusion pump, and the miniaturization of the generator column and catheter system. Results are presented of studies of 81 Krsup(m) distribution in dogs, using both intravenous and intra-arterial infusion. (author)

  17. Chronic intrastriatal dopamine infusions in rats with unilateral lesions of the substantia nigra

    International Nuclear Information System (INIS)

    Hargraves, R.; Freed, W.J.

    1987-01-01

    This study examined the effects of continuously supplied dopamine delivered directly into the dopamine-deficient striatum. Rats received unilateral lesions of the substantia nigra by stereotaxic administration of 6-hydroxydopamine and were tested for apomorphine-induced rotational behavior and general activity. Osmotic mini-pumps were filled with dopamine in various concentrations, implanted subcutaneously and connected to a cannula implanted directly into the striatum. The system delivered solution at a rate of .5 μl/hr for two weeks. Dopamine in a dosage of 0.5 μg/per hour reduced apomorphine-induced rotational behavior by a mean of 52 +/- 5.8% (mean +/- SEM n=20) with a maximal individual decrease of 99%. There was no change in general activity or increase in stereotype behavior. Infusions of vehicle solutions did not decrease rotational behavior. Spread of the infused dopamine and its metabolites was estimated by adding 3 H-dopamine to the pumps in tracer quantities. Radioactivity was highly concentrated at the infusion site and decreased rapidly within a few mm from the infusion site. Continuous infusion methods may eventually prove to be effective in the treatment of nigro-striatal degenerative disease. 12 references, 4 figures

  18. Weekly ascorbic acid infusion in castration-resistant prostate cancer patients

    DEFF Research Database (Denmark)

    Nielsen, Torben K.; Højgaard, Martin; Andersen, Jon T.

    2017-01-01

    of this treatment. Methods: This non-comparative, single-center, phase II trial included patients with chemotherapy-naïve, metastatic castration-resistant prostate cancer (mCRPC) from an outpatient clinic to evaluate the efficacy and safety of IV AA therapy. Patients received weekly infusions of AA (week 1, 5 g....../L was recorded at week 12. Among the secondary endpoints, no signs of disease remission were observed. In total, 53 adverse events (AEs) were recorded. Eleven were graded as "serious". Three AEs were directly related to AA, and all of which were related to fluid load. Conclusions: Infusion with 60 g of AA did...

  19. Seed oil triglyceride profiling of thirty-two hybrid grape varieties.

    Science.gov (United States)

    De Marchi, Fabiola; Seraglia, Roberta; Molin, Laura; Traldi, Pietro; De Rosso, Mirko; Panighel, Annarita; Dalla Vedova, Antonio; Gardiman, Massimo; Giust, Mirella; Flamini, Riccardo

    2012-09-01

    Triglyceride profile of seed oil samples from 32 hybrid grape varieties not studied before was investigated. A new method for the analysis of triacylglycerols (TAGs) has been developed based on the direct infusion in the electrospray ionization (ESI) source and employing tetrahydrofuran/methanol/water (85:10:5 v|v|v) as solvent; the formation of [M + Na](+) ions in high yield has been observed. TAGs were identified by ESI-tandem mass spectrometry analysis, and the matrix-assisted-laser-desorption-ionization and time-of-flight profile of samples was determined. Six were the principal TAGs identified in seed oil: trilinolein (LLL) was the most abundant (43%), followed by dilinoleoyl-oleoylglycerol (LOL, 23%), and dilinoleoyl-palmitoylglycerol (LPL, 15%). Compounds present in lower concentration were LSL and LOO (11%), LOP (6%), and LSP (2%). Compared with seed oils produced from V. Vinifera grapes, some significant differences in the relative abundances of TAGs were found, in particular hybrid grape seed oils showed higher LOL and lower LPL content, respectively. Among the samples studied, a particularly high content of LLL (rich in unsaturated fatty acids) was found in seed oils from two red varieties. Copyright © 2012 John Wiley & Sons, Ltd.

  20. In vivo tracking of {sup 111}In-oxine labeled mesenchymal stem cells following infusion in patients with advanced cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Gholamrezanezhad, Ali, E-mail: agholam1@jhmi.edu [Research Institute for Nuclear Medicine. Shariati Hospital. Tehran University of Medical Sciences, Tehran, 14114 (Iran, Islamic Republic of); Mirpour, Sahar [Research Institute for Nuclear Medicine. Shariati Hospital. Tehran University of Medical Sciences, Tehran, 14114 (Iran, Islamic Republic of); Bagheri, Mohammad; Mohamadnejad, Mehdi [Digestive Disease Research Center. Shariati Hospital. Tehran University of Medical Sciences, Tehran, 14114 (Iran, Islamic Republic of); Alimoghaddam, Kamran [Hematology and BMT Research Center. Shariati Hospital. Tehran University of Medical Sciences, Tehran, 14114 (Iran, Islamic Republic of); Abdolahzadeh, Leila [Digestive Disease Research Center. Shariati Hospital. Tehran University of Medical Sciences, Tehran, 14114 (Iran, Islamic Republic of); Saghari, Mohsen [Research Institute for Nuclear Medicine. Shariati Hospital. Tehran University of Medical Sciences, Tehran, 14114 (Iran, Islamic Republic of); Malekzadeh, Reza [Digestive Disease Research Center. Shariati Hospital. Tehran University of Medical Sciences, Tehran, 14114 (Iran, Islamic Republic of)

    2011-10-15

    Background: Several animal and few human studies suggest the beneficial role of bone marrow mesenchymal stem cells (MSCs) in liver cirrhosis. However, little is known about the fate of MSCs after infusion in cirrhotic patients. We evaluated stem cell biodistribution after peripheral infusion of MSCs in four cirrhotic patients. Methods: After three passages of MSCs, the patients received a total of 250-400x10{sup 6} cells, of which only 50% of the cells were labeled. Specific activities of 0.21-0.67 MBq/10{sup 6} cells were maintained for the injected labeled MSCs. Planar whole-body acquisitions (anterior/posterior projections) were acquired immediately following infusion as well as at 2 h, 4 h, 6 h, 24 h, 48 h, 7th and 10th days after cell infusion. Results: After intravenous infusion, the radioactivity was first observed to accumulate in the lungs. During the following hours to days, the radioactivity gradually increased in the liver and spleen, with spleen uptake exceeding that in the liver in all patients. Region-of-interest analysis showed that the percentage of cells homing to the liver (following decay and background corrections and geometric mean calculation) increased from 0.0%-2.8% at immediately post-infusion images to 13.0-17.4% in 10th-day post-infusion. Similarly, the residual activities in the spleen increased from 2.0%-10.2% at immediately post-infusion images to 30.1%-42.2% in 10th-day post-infusion. During the same period, the residual activities in the lungs decreased from 27.0-33.5% to 2.0-5.4%. Conclusion: The infusion of MSCs labeled with {sup 111}In-oxine through a peripheral vein is safe in cirrhosis. Cell labeling with {sup 111}In-oxine is a suitable method for tracking MSC distribution after infusion.

  1. Extending the subspace hybrid method for eigenvalue problems in reactor physics calculation

    International Nuclear Information System (INIS)

    Zhang, Q.; Abdel-Khalik, H. S.

    2013-01-01

    This paper presents an innovative hybrid Monte-Carlo-Deterministic method denoted by the SUBSPACE method designed for improving the efficiency of hybrid methods for reactor analysis applications. The SUBSPACE method achieves its high computational efficiency by taking advantage of the existing correlations between desired responses. Recently, significant gains in computational efficiency have been demonstrated using this method for source driven problems. Within this work the mathematical theory behind the SUBSPACE method is introduced and extended to address core wide level k-eigenvalue problems. The method's efficiency is demonstrated based on a three-dimensional quarter-core problem, where responses are sought on the pin cell level. The SUBSPACE method is compared to the FW-CADIS method and is found to be more efficient for the utilized test problem because of the reason that the FW-CADIS method solves a forward eigenvalue problem and an adjoint fixed-source problem while the SUBSPACE method only solves an adjoint fixed-source problem. Based on the favorable results obtained here, we are confident that the applicability of Monte Carlo for large scale reactor analysis could be realized in the near future. (authors)

  2. A hybrid source-driven method to compute fast neutron fluence in reactor pressure vessel - 017

    International Nuclear Information System (INIS)

    Ren-Tai, Chiang

    2010-01-01

    A hybrid source-driven method is developed to compute fast neutron fluence with neutron energy greater than 1 MeV in nuclear reactor pressure vessel (RPV). The method determines neutron flux by solving a steady-state neutron transport equation with hybrid neutron sources composed of peripheral fixed fission neutron sources and interior chain-reacted fission neutron sources. The relative rod-by-rod power distribution of the peripheral assemblies in a nuclear reactor obtained from reactor core depletion calculations and subsequent rod-by-rod power reconstruction is employed as the relative rod-by-rod fixed fission neutron source distribution. All fissionable nuclides other than U-238 (such as U-234, U-235, U-236, Pu-239 etc) are replaced with U-238 to avoid counting the fission contribution twice and to preserve fast neutron attenuation for heavy nuclides in the peripheral assemblies. An example is provided to show the feasibility of the method. Since the interior fuels only have a marginal impact on RPV fluence results due to rapid attenuation of interior fast fission neutrons, a generic set or one of several generic sets of interior fuels can be used as the driver and only the neutron sources in the peripheral assemblies will be changed in subsequent hybrid source-driven fluence calculations. Consequently, this hybrid source-driven method can simplify and reduce cost for fast neutron fluence computations. This newly developed hybrid source-driven method should be a useful and simplified tool for computing fast neutron fluence at selected locations of interest in RPV of contemporary nuclear power reactors. (authors)

  3. Clinical applications of continuous infusion chemotherapy ahd concomitant radiation therapy

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Rotman, M.

    1986-01-01

    This book presents information on the following topics: theoretical basis and clinical applications of 5-FU as a radiosensitizer; treatment of hepatic metastases from gastro intestingal primaries with split course radiation therapy; combined modality therapy with 5-FU, Mitomycin-C and radiation therapy for sqamous cell cancers; treatment of bladder carcinoma with concomitant infusion chemotherapy and irradiation; a treatment of invasiv bladder cancer by the XRT/5FU protocol; concomitant radiation therapy and doxorubicin by continuous infusion in advanced malignancies; cis platin by continuous infusion with concurrent radiation therapy in malignant tumors; combination of radiation with concomitant continuous adriamycin infusion in a patient with partially excised pleomorphic soft tissue sarcoma of the lower extremeity; treatment of recurrent carcinoma of the paranasal sinuses using concomitant infusion cis-platinum and radiation therapy; hepatic artery infusion for hepatic metastases in combination with hepatic resection and hepatic radiation; study of simultaneous radiation therapy, continuous infusion, 5FU and bolus mitomycin-C; cancer of the esophagus; continuous infusion VP-16, bolus cis-platinum and simultaneous radiation therapy as salvage therapy in small cell bronchogenic carcinoma; and concomitant radiation, mitomycin-C and 5-FU infusion in gastro intestinal cancer

  4. A Hybrid Maximum Power Point Tracking Method for Automobile Exhaust Thermoelectric Generator

    Science.gov (United States)

    Quan, Rui; Zhou, Wei; Yang, Guangyou; Quan, Shuhai

    2017-05-01

    To make full use of the maximum output power of automobile exhaust thermoelectric generator (AETEG) based on Bi2Te3 thermoelectric modules (TEMs), taking into account the advantages and disadvantages of existing maximum power point tracking methods, and according to the output characteristics of TEMs, a hybrid maximum power point tracking method combining perturb and observe (P&O) algorithm, quadratic interpolation and constant voltage tracking method was put forward in this paper. Firstly, it searched the maximum power point with P&O algorithms and a quadratic interpolation method, then, it forced the AETEG to work at its maximum power point with constant voltage tracking. A synchronous buck converter and controller were implemented in the electric bus of the AETEG applied in a military sports utility vehicle, and the whole system was modeled and simulated with a MATLAB/Simulink environment. Simulation results demonstrate that the maximum output power of the AETEG based on the proposed hybrid method is increased by about 3.0% and 3.7% compared with that using only the P&O algorithm and the quadratic interpolation method, respectively. The shorter tracking time is only 1.4 s, which is reduced by half compared with that of the P&O algorithm and quadratic interpolation method, respectively. The experimental results demonstrate that the tracked maximum power is approximately equal to the real value using the proposed hybrid method,and it can preferentially deal with the voltage fluctuation of the AETEG with only P&O algorithm, and resolve the issue that its working point can barely be adjusted only with constant voltage tracking when the operation conditions change.

  5. Hybrid Monte Carlo-Diffusion Method For Light Propagation in Tissue With a Low-Scattering Region

    Science.gov (United States)

    Hayashi, Toshiyuki; Kashio, Yoshihiko; Okada, Eiji

    2003-06-01

    The heterogeneity of the tissues in a head, especially the low-scattering cerebrospinal fluid (CSF) layer surrounding the brain has previously been shown to strongly affect light propagation in the brain. The radiosity-diffusion method, in which the light propagation in the CSF layer is assumed to obey the radiosity theory, has been employed to predict the light propagation in head models. Although the CSF layer is assumed to be a nonscattering region in the radiosity-diffusion method, fine arachnoid trabeculae cause faint scattering in the CSF layer in real heads. A novel approach, the hybrid Monte Carlo-diffusion method, is proposed to calculate the head models, including the low-scattering region in which the light propagation does not obey neither the diffusion approximation nor the radiosity theory. The light propagation in the high-scattering region is calculated by means of the diffusion approximation solved by the finite-element method and that in the low-scattering region is predicted by the Monte Carlo method. The intensity and mean time of flight of the detected light for the head model with a low-scattering CSF layer calculated by the hybrid method agreed well with those by the Monte Carlo method, whereas the results calculated by means of the diffusion approximation included considerable error caused by the effect of the CSF layer. In the hybrid method, the time-consuming Monte Carlo calculation is employed only for the thin CSF layer, and hence, the computation time of the hybrid method is dramatically shorter than that of the Monte Carlo method.

  6. Effect of intra-hepatic arterial infusion chemotherapy for patients with liver metastasis from breast cancer

    International Nuclear Information System (INIS)

    Liu Dezhong; Li Huai; Zeng Huiying; Yang Ling

    2001-01-01

    Objective: To evaluate the efficacy of intra-hepatic arterial infusion chemotherapy for patients with liver metastasis from breast cancer. Methods: 1993-1998 years, Thirty four patients with liver metastasis from breast cancer had received epi-adriamycin, cisplatin, mitomycin and 5-fluorouracil by intrahepatic arterial infusion chemotherapy. Twelve patients had received embolization. Results: Six patients (17.65%) had a complete response, 12 patients (35.29%) had a partial response. The overall response rate was 52.94%. Cumulative survival rates at 1, 2, 3 and 4 years were 56.90%, 25.00%, 5.00% and 5.00% respectively (Kaplan-Meier method). The median overall survival time was 11.5 months. Conclusion: Intra-hepatic arterial infusion chemotherapy is safe and effective for liver metastasis from breast cancer and should be the first choice of treatment for these patients

  7. Replacement of oxytocin bolus administration by infusion: influences on postpartum outcome.

    Science.gov (United States)

    Löytved-Hardegg, Julia J; Brunner, Mirjam; Ries, Jean-Jacques; von Felten, Stefanie; Heugel, Christina; Lapaire, Olav; Voekt, Cora; Hösli, Irene

    2016-06-01

    Postpartum haemorrhage (PPH) represents a leading cause of maternal morbidity and mortality. Giving oxytocin after birth reduces the risk for PPH. It has never been tested whether different methods of oxytocin administration affect the maternal outcome. This study aims to compare the infusion versus the bolus application of oxytocin after singleton vaginal delivery. This retrospective monocentre study compares the incidence of clinically relevant postpartum complications in women receiving 5 IE of oxytocin as a bolus or as a 100 ml-infusion over 5 min, given immediately after birth. Included were women delivering singletons vaginally at term. We used propensity score weighting to compare outcomes between women receiving bolus and infusion and to minimize the selection bias in this retrospective cohort. 1765 patients were included. Patient characteristics were balanced. We found no significant differences for the combined overall postpartum adverse outcome (the incidence of PPH, manual removal of the placenta and/or curettage). For the single outcomes, we observed a significantly higher frequency of manual removal of the placenta (Odds ratio 1.47, 95 % CI 1.02-2.13) and a slightly higher but clinically not relevant estimated blood loss (Relative effect 1.05, 95 % CI 1.01-1.10) in the infusion group. The data show a tendency towards more complications in the infusion group. It is related to a more frequent need for manual removal of the placenta.

  8. Single-dose intravenous iron infusion or oral iron for treatment of fatigue after postpartum haemorrhage

    DEFF Research Database (Denmark)

    Holm, C; Thomsen, L L; Norgaard, A

    2017-01-01

    BACKGROUND AND OBJECTIVES: To evaluate the clinical efficacy of a single-dose intravenous infusion of iron isomaltoside compared with current treatment practice with oral iron measured by physical fatigue in women after postpartum haemorrhage. MATERIALS AND METHODS: Single-centre, open-label, ran......BACKGROUND AND OBJECTIVES: To evaluate the clinical efficacy of a single-dose intravenous infusion of iron isomaltoside compared with current treatment practice with oral iron measured by physical fatigue in women after postpartum haemorrhage. MATERIALS AND METHODS: Single-centre, open...

  9. A hybrid method for flood simulation in small catchments combining hydrodynamic and hydrological techniques

    Science.gov (United States)

    Bellos, Vasilis; Tsakiris, George

    2016-09-01

    The study presents a new hybrid method for the simulation of flood events in small catchments. It combines a physically-based two-dimensional hydrodynamic model and the hydrological unit hydrograph theory. Unit hydrographs are derived using the FLOW-R2D model which is based on the full form of two-dimensional Shallow Water Equations, solved by a modified McCormack numerical scheme. The method is tested at a small catchment in a suburb of Athens-Greece for a storm event which occurred in February 2013. The catchment is divided into three friction zones and unit hydrographs of 15 and 30 min are produced. The infiltration process is simulated by the empirical Kostiakov equation and the Green-Ampt model. The results from the implementation of the proposed hybrid method are compared with recorded data at the hydrometric station at the outlet of the catchment and the results derived from the fully hydrodynamic model FLOW-R2D. It is concluded that for the case studied, the proposed hybrid method produces results close to those of the fully hydrodynamic simulation at substantially shorter computational time. This finding, if further verified in a variety of case studies, can be useful in devising effective hybrid tools for the two-dimensional flood simulations, which are lead to accurate and considerably faster results than those achieved by the fully hydrodynamic simulations.

  10. Effect of nitrous oxide on cisatracurium infusion demands: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Illman Hanna L

    2010-08-01

    Full Text Available Abstract Background Recent studies have questioned our previous understanding on the effect of nitrous oxide on muscle relaxants, since nitrous oxide has been shown to potentiate the action of bolus doses of mivacurium, rocuronium and vecuronium. This study was aimed to investigate the possible effect of nitrous oxide on the infusion requirements of cisatracurium. Methods 70 ASA physical status I-III patients aged 18-75 years were enrolled in this randomized trial. The patients were undergoing elective surgery requiring general anesthesia with a duration of at least 90 minutes. Patients were randomized to receive propofol and remifentanil by target controlled infusion in combination with either a mixture of oxygen and nitrous oxide (Nitrous oxide/TIVA group or oxygen in air (Air/TIVA group. A 0.1 mg/kg initial bolus of cisatracurium was administered before tracheal intubation, followed by a closed-loop computer controlled infusion of cisatracurium to produce and maintain a 90% neuromuscular block. Cumulative dose requirements of cisatracurium during the 90-min study period after bolus administration were measured and the asymptotic steady state rate of infusion to produce a constant 90% block was determined by applying nonlinear curve fitting to the data on the cumulative dose requirement during the study period. Results Controller performance, i.e. the ability of the controller to maintain neuromuscular block constant at the setpoint and patient characteristics were similar in both groups. The administration of nitrous oxide did not affect cisatracurium infusion requirements. The mean steady-state rates of infusion were 0.072 +/- 0.018 and 0.066 +/- 0.017 mg * kg-1 * h-1 in Air/TIVA and Nitrous oxide/TIVA groups, respectively. Conclusions Nitrous oxide does not affect the infusion requirements of cisatracurium. Trial registration ClinicalTrials.gov NCT01152905; European Clinical Trials Database at http://eudract.emea.eu.int/2006-006037-41.

  11. The Ion Cyclotron, Lower Hybrid, and Alfven Wave Heating Methods

    International Nuclear Information System (INIS)

    Koch, R.

    2004-01-01

    This lecture covers the practical features and experimental results of the three heating methods. The emphasis is on ion cyclotron heating. First, we briefly come back to the main non-collisional heating mechanisms and to the particular features of the quasilinear coefficient in the ion cyclotron range of frequencies (ICRF). The specific case of the ion-ion hybrid resonance is treated, as well as the polarisation issue and minority heating scheme. The various ICRF scenarios are reviewed. The experimental applications of ion cyclotron resonance heating (ICRH) systems are outlined. Then, the lower hybrid and Alfven wave heating and current drive experimental results are covered more briefly. Where applicable, the prospects for ITER are commented

  12. Canadian Palliative Community Milrinone Infusions: A Case Series.

    Science.gov (United States)

    Reimche, Ruthanne; Salcedo, Daniel

    2016-01-01

    Abstract Symptom managementfor end-of-life heartfailure (HF) patients is a significant concern. Currently, Canadian practice does not support community milrinone therapy in end-of-life HF patients. Two patients had severe HF that was unresponsive to optimal medications. Further optimization and furosemide infusions were ineffective for symptom management. Both patients' symptoms were better controlled with optimal medication, furosemide, and milrinone infusions. A tailored discharge plan was developed to assist with community milrinone infusions. We discuss the challenges and successes of transitioning two patients to the community. By providing symptom management and meaningful patient and family experience, both patients were able to die in a setting of their choosing. Milrinone infusions as a bridge to end of life may improve symptoms and quality of life. Select patients may benefit from milrinone infusions with resources put in place; these end-of-life HF patients can be supported in the community.

  13. A randomised controlled trial of two infusion rates to decrease reactions to antivenom.

    Directory of Open Access Journals (Sweden)

    Geoffrey K Isbister

    Full Text Available BACKGROUND: Snake envenoming is a major clinical problem in Sri Lanka, with an estimated 40,000 bites annually. Antivenom is only available from India and there is a high rate of systemic hypersensitivity reactions. This study aimed to investigate whether the rate of infusion of antivenom reduced the frequency of severe systemic hypersensitivity reactions. METHODS AND FINDINGS: This was a randomized comparison trial of two infusion rates of antivenom for treatment of non-pregnant adult patients (>14 y with snake envenoming in Sri Lanka. Snake identification was by patient or hospital examination of dead snakes when available and confirmed by enzyme-immunoassay for Russell's viper envenoming. Patients were blindly allocated in a 11 randomisation schedule to receive antivenom either as a 20 minute infusion (rapid or a two hour infusion (slow. The primary outcome was the proportion with severe systemic hypersensitivity reactions (grade 3 by Brown grading system within 4 hours of commencement of antivenom. Secondary outcomes included the proportion with mild/moderate hypersensitivity reactions and repeat antivenom doses. Of 1004 patients with suspected snakebites, 247 patients received antivenom. 49 patients were excluded or not recruited leaving 104 patients allocated to the rapid antivenom infusion and 94 to the slow antivenom infusion. The median actual duration of antivenom infusion in the rapid group was 20 min (Interquartile range[IQR]:20-25 min versus 120 min (IQR:75-120 min in the slow group. There was no difference in severe systemic hypersensitivity reactions between those given rapid and slow infusions (32% vs. 35%; difference 3%; 95%CI:-10% to +17%;p = 0.65. The frequency of mild/moderate reactions was also similar. Similar numbers of patients in each arm received further doses of antivenom (30/104 vs. 23/94. CONCLUSIONS: A slower infusion rate would not reduce the rate of severe systemic hypersensitivity reactions from current high

  14. A new infusion pathway intactness monitoring system.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2006-01-01

    A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).

  15. Plasma Calcium, Inorganic Phosphate and Magnesium During Hypocalcaemia Induced by a Standardized EDTA Infusion in Cows

    Directory of Open Access Journals (Sweden)

    Enemark JMD

    2001-06-01

    Full Text Available The intravenous Na2EDTA infusion technique allows effective specific chelation of circulating Ca2+ leading to a progressive hypocalcaemia. Methods previously used were not described in detail and results obtained by monitoring total and free ionic calcium were not comparable due to differences in sampling and analysis. This paper describes a standardized EDTA infusion technique that allowed comparison of the response of calcium, phosphorus and magnesium between 2 groups of experimental cows. The concentration of the Na2EDTA solution was 0.134 mol/l and the flow rate was standardized at 1.2 ml/kg per hour. Involuntary recumbency occurred when ionised calcium dropped to 0.39 – 0.52 mmol/l due to chelation. An initial fast drop of ionized calcium was observed during the first 20 min of infusion followed by a fluctuation leading to a further drop until recumbency. Pre-infusion [Ca2+] between tests does not correlate with the amount of EDTA required to induce involuntary recumbence. Total calcium concentration measured by atomic absorption remained almost constant during the first 100 min of infusion but declined gradually when the infusion was prolonged. The concentration of inorganic phosphate declined gradually in a fluctuating manner until recumbency. Magnesium concentration remained constant during infusion. Such electrolyte responses during infusion were comparable to those in spontaneous milk fever. The standardized infusion technique might be useful in future experimental studies.

  16. Adaptive mixed-hybrid and penalty discontinuous Galerkin method for two-phase flow in heterogeneous media

    KAUST Repository

    Hou, Jiangyong

    2016-02-05

    In this paper, we present a hybrid method, which consists of a mixed-hybrid finite element method and a penalty discontinuous Galerkin method, for the approximation of a fractional flow formulation of a two-phase flow problem in heterogeneous media with discontinuous capillary pressure. The fractional flow formulation is comprised of a wetting phase pressure equation and a wetting phase saturation equation which are coupled through a total velocity and the saturation affected coefficients. For the wetting phase pressure equation, the continuous mixed-hybrid finite element method space can be utilized due to a fundamental property that the wetting phase pressure is continuous. While it can reduce the computational cost by using less degrees of freedom and avoiding the post-processing of velocity reconstruction, this method can also keep several good properties of the discontinuous Galerkin method, which are important to the fractional flow formulation, such as the local mass balance, continuous normal flux and capability of handling the discontinuous capillary pressure. For the wetting phase saturation equation, the penalty discontinuous Galerkin method is utilized due to its capability of handling the discontinuous jump of the wetting phase saturation. Furthermore, an adaptive algorithm for the hybrid method together with the centroidal Voronoi Delaunay triangulation technique is proposed. Five numerical examples are presented to illustrate the features of proposed numerical method, such as the optimal convergence order, the accurate and efficient velocity approximation, and the applicability to the simulation of water flooding in oil field and the oil-trapping or barrier effect phenomena.

  17. Adaptive mixed-hybrid and penalty discontinuous Galerkin method for two-phase flow in heterogeneous media

    KAUST Repository

    Hou, Jiangyong; Chen, Jie; Sun, Shuyu; Chen, Zhangxin

    2016-01-01

    In this paper, we present a hybrid method, which consists of a mixed-hybrid finite element method and a penalty discontinuous Galerkin method, for the approximation of a fractional flow formulation of a two-phase flow problem in heterogeneous media with discontinuous capillary pressure. The fractional flow formulation is comprised of a wetting phase pressure equation and a wetting phase saturation equation which are coupled through a total velocity and the saturation affected coefficients. For the wetting phase pressure equation, the continuous mixed-hybrid finite element method space can be utilized due to a fundamental property that the wetting phase pressure is continuous. While it can reduce the computational cost by using less degrees of freedom and avoiding the post-processing of velocity reconstruction, this method can also keep several good properties of the discontinuous Galerkin method, which are important to the fractional flow formulation, such as the local mass balance, continuous normal flux and capability of handling the discontinuous capillary pressure. For the wetting phase saturation equation, the penalty discontinuous Galerkin method is utilized due to its capability of handling the discontinuous jump of the wetting phase saturation. Furthermore, an adaptive algorithm for the hybrid method together with the centroidal Voronoi Delaunay triangulation technique is proposed. Five numerical examples are presented to illustrate the features of proposed numerical method, such as the optimal convergence order, the accurate and efficient velocity approximation, and the applicability to the simulation of water flooding in oil field and the oil-trapping or barrier effect phenomena.

  18. Observation of the medium-long term efficacy of infusion chemotherapy in middle-terminal stage esophageal carcinomas

    International Nuclear Information System (INIS)

    Song Taimin; Han Xinwei; Wu Gang

    2005-01-01

    Objective: To explore the infusion chemotherapeutic efficacy and clinical application value for patients with middle-terminal stage esophageal carcinomas. Methods: Eighty patients with esophageal squamous carcinoma confirmed with barium meal examination and histopathology were undergone angiography and infusion chemotherapy through catheter in the target artery of the esophageal tumor. Results: Complete relief were acquired in 26 of 80 patients after the infusion, partial relief in 42, no-change in 11 and progress in 1; the overall effective rate was 85%(68/80). The survival rates was 87.5%(70/80), 38.8%(31/80), 21.3%(17/80), 15%(12/80) at 1, 2, 3 and 5 year intervals respectively. The patients of more than 3 years survival were complete symptomlessness after infusion. The survival rate could be improved significantly with infusion as long as necessary. Conclusions: The short-term efficacy with infusion is remarkable and should be the preferable choice, but the medium-long term survival rate is still low. Accomplishment with other therapies is further to be recommended. (authors)

  19. Development of a Hybrid RANS/LES Method for Turbulent Mixing Layers

    Science.gov (United States)

    Georgiadis, Nicholas J.; Alexander, J. Iwan D.; Reshotko, Eli

    2001-01-01

    Significant research has been underway for several years in NASA Glenn Research Center's nozzle branch to develop advanced computational methods for simulating turbulent flows in exhaust nozzles. The primary efforts of this research have concentrated on improving our ability to calculate the turbulent mixing layers that dominate flows both in the exhaust systems of modern-day aircraft and in those of hypersonic vehicles under development. As part of these efforts, a hybrid numerical method was recently developed to simulate such turbulent mixing layers. The method developed here is intended for configurations in which a dominant structural feature provides an unsteady mechanism to drive the turbulent development in the mixing layer. Interest in Large Eddy Simulation (LES) methods have increased in recent years, but applying an LES method to calculate the wide range of turbulent scales from small eddies in the wall-bounded regions to large eddies in the mixing region is not yet possible with current computers. As a result, the hybrid method developed here uses a Reynolds-averaged Navier-Stokes (RANS) procedure to calculate wall-bounded regions entering a mixing section and uses a LES procedure to calculate the mixing-dominated regions. A numerical technique was developed to enable the use of the hybrid RANS-LES method on stretched, non-Cartesian grids. With this technique, closure for the RANS equations is obtained by using the Cebeci-Smith algebraic turbulence model in conjunction with the wall-function approach of Ota and Goldberg. The LES equations are closed using the Smagorinsky subgrid scale model. Although the function of the Cebeci-Smith model to replace all of the turbulent stresses is quite different from that of the Smagorinsky subgrid model, which only replaces the small subgrid turbulent stresses, both are eddy viscosity models and both are derived at least in part from mixing-length theory. The similar formulation of these two models enables the RANS

  20. Inhibition of endogenous lactate turnover with lactate infusion in humans

    International Nuclear Information System (INIS)

    Searle, G.L.; Feingold, K.R.; Hsu, F.S.; Clark, O.H.; Gertz, E.W.; Stanley, W.C.

    1989-01-01

    The extent to which lactate infusion may inhibit endogenous lactate production, though previously considered, has never been critically assessed. To examine this proposition, single injection tracer methodology (U- 14 C Lactate) has been used for the estimation of lactate kinetics in 12 human subjects under basal conditions and with the infusion of sodium lactate. The basal rate of lactate turnover was measured on a day before the study with lactate infusion, and averaged 63.7 + 5.5 mg/kg/h. Six of these individuals received a stable lactate infusion at an approximate rate of 160 mg/kg/h, while the remaining six individuals were infused at the approximate rate of 100 mg/kg/h. It has been found that stable lactate infused at rates approximating 160 mg/kg/h consistently produced a complete inhibition of endogenous lactate production. Infusion of lactate at 100 mg/kg/h caused a lesser and more variable inhibition of endogenous lactate production (12% to 64%). In conclusion, lactate infusion significantly inhibits endogenous lactate production

  1. Changes in circulating blood volume after infusion of hydroxyethyl starch 6% in critically ill patients

    DEFF Research Database (Denmark)

    Christensen, P; Andersson, J; Rasmussen, S E

    2001-01-01

    The cardiovascular response to a volume challenge with hydroxyethyl starch (HES) (200/0.5) 6% depends on the relation between the volume of HES 6% infused and the expansion of the blood volume in critically ill patients. However, only relatively limited data exist on the plasma expanding effect...... of infusion of HES 6% in critically ill patients. The purpose of the study was to evaluate the variation in the expansion of the circulating blood volume (CBV) in critically ill patients after infusion of 500 ml of colloid (HES (200/0.5) 6%) using the carbon monoxide method....

  2. Síndrome da infusão do propofol Síndrome de la infusión del propofol Propofol infusion syndrome

    Directory of Open Access Journals (Sweden)

    Fabiano Timbó Barbosa

    2007-10-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A síndrome da infusão do propofol tem sido descrita como uma síndrome rara e quase sempre fatal que ocorre após infusão prolongada desse fármaco. Ela pode resultar em acidose metabólica grave, rabdomiólise, colapso cardiovascular e morte. O objetivo deste artigo foi mostrar aspectos relacionados com a síndrome da infusão do propofol por meio da revisão de literatura. CONTEÚDO: Estão definidas as características da síndrome da infusão do propofol quanto à fisiopatologia, características clínicas, tratamento e recomendações de dose para pacientes gravemente enfermos. CONCLUSÕES: O propofol deve ser usado com cautela quando se planeja seu uso sob regime de infusão contínua por períodos prolongados. O surgimento de sinais sugestivos da síndrome da infusão do propofol indica a suspensão imediata do fármaco e início de medidas de suporte.JUSIFICATIVA Y OBJETIVOS: El síndrome de la infusión del propofol ha sido descrito como un síndrome raro y frecuentemente fatal que ocurre después de la infusión prolongada de ese fármaco. Puede resultar en acidez metabólica grave, rabdomiólisis, colapso cardiovascular y deceso. El objetivo de este artículo fue mostrar aspectos relacionados al síndrome de la infusión del propofol a través de la revisión de la literatura. CONTENIDO: Están definidas las características del síndrome de la infusión del propofol en cuanto a la fisiopatología, características clínicas, tratamiento y recomendaciones de dosis para pacientes gravemente enfermos. CONCLUSIONES: El propofol debe ser usado con cautela cuando se planea su uso bajo el régimen de infusión continua por períodos prolongados. El aparecimiento de señales sugestivas del síndrome de la infusión del propofol indica la suspensión inmediata del fármaco y el inicio de medidas de soporte.BACKGROUND AND OBJECTIVES: Propofol infusion syndrome has been described as a rare, and frequently fatal

  3. Block Hybrid Collocation Method with Application to Fourth Order Differential Equations

    Directory of Open Access Journals (Sweden)

    Lee Ken Yap

    2015-01-01

    Full Text Available The block hybrid collocation method with three off-step points is proposed for the direct solution of fourth order ordinary differential equations. The interpolation and collocation techniques are applied on basic polynomial to generate the main and additional methods. These methods are implemented in block form to obtain the approximation at seven points simultaneously. Numerical experiments are conducted to illustrate the efficiency of the method. The method is also applied to solve the fourth order problem from ship dynamics.

  4. A new method of hybrid frequency hopping signals selection and blind parameter estimation

    Science.gov (United States)

    Zeng, Xiaoyu; Jiao, Wencheng; Sun, Huixian

    2018-04-01

    Frequency hopping communication is widely used in military communications at home and abroad. In the case of single-channel reception, it is scarce to process multiple frequency hopping signals both effectively and simultaneously. A method of hybrid FH signals selection and blind parameter estimation is proposed. The method makes use of spectral transformation, spectral entropy calculation and PRI transformation basic theory to realize the sorting and parameter estimation of the components in the hybrid frequency hopping signal. The simulation results show that this method can correctly classify the frequency hopping component signal, and the estimated error of the frequency hopping period is about 5% and the estimated error of the frequency hopping frequency is less than 1% when the SNR is 10dB. However, the performance of this method deteriorates seriously at low SNR.

  5. An Efficient Hybrid Conjugate Gradient Method with the Strong Wolfe-Powell Line Search

    Directory of Open Access Journals (Sweden)

    Ahmad Alhawarat

    2015-01-01

    Full Text Available Conjugate gradient (CG method is an interesting tool to solve optimization problems in many fields, such as design, economics, physics, and engineering. In this paper, we depict a new hybrid of CG method which relates to the famous Polak-Ribière-Polyak (PRP formula. It reveals a solution for the PRP case which is not globally convergent with the strong Wolfe-Powell (SWP line search. The new formula possesses the sufficient descent condition and the global convergent properties. In addition, we further explained about the cases where PRP method failed with SWP line search. Furthermore, we provide numerical computations for the new hybrid CG method which is almost better than other related PRP formulas in both the number of iterations and the CPU time under some standard test functions.

  6. The effect of barium infusion rate on the diagnostic value of small bowel enteroclysis

    International Nuclear Information System (INIS)

    Oudkerk, M.; Rijke, A.M.

    1988-01-01

    Although enteroclysis may have many advantages over the conventional methods of small bowel examination, the contrast material is not always infused at a rate appropriate to gain maximum diagnostic information. In this study, 190 patients were examined by small bowell enteroclysis at five contrast infusion rates ranging from 50 to 150 ml/min using a newly designed infusion pump system. The results show that at rates above 75 ml/min, motility disturbances are masked by small bowel dilatation and paralysis, transit times are extended and morphological detail is obscured. At rates below 75 ml/min, incomplete filling of the loops renders optimal diagnostic evaluation impossible. An infusion rate of 75 ml/min was found to be optimal for initiating small bowel studies. This rate can be adjusted for individual cases when pathology or drugs affect the motility of the small bowel. 13 refs.; 5 figs.; 1 table

  7. Apoptosis and histological response of preoperative intraarterial chemotherapy infusion for colorectal carcinoma

    International Nuclear Information System (INIS)

    Yuan Jianhua; Hu Tingyang; Yu Wenqiang; Chen Fanghong; Luo Zuyan; Mao Yinmin; Zhao Zhongsheng; Ru Guoqing; Deng Gaoli; Dong Quanjin; Tu Shiliang

    2003-01-01

    Objective: To investigate apoptosis and histological response of preoperative intraarterial chemotherapy infusion for colorectal carcinoma. Methods: Fifty patients with colorectal carcinoma were treated by intraarterial infusion of anti-cancer drugs. Surgical resection of the tumor was performed 5-30 days after the intraarterial infusion (mean 12 days). The histological response was evaluated. The density and distribution of the apoptosis cells were observed by DNA nick end labelling technique. 22 biopsy specimens before the intraarterial chemotherapy and 25 normal mucosa (obtained from surgery specimen) were used as controls. Results: The total histological response rate was 100% with grade I in 20 cases, grade II in 21 cases, and grade III in 9 cases. The density of the apoptosis cells was 31.47±5.58 before and 76.69±17.12 after the intraarterial chemotherapy infusion, and 8.01±3.39 in normal mucosa, respectively. The density of the apoptosis cells after the intraarterial chemotherapy was significantly higher than that before the intraarterial chemotherapy (t=13.701, P 2 =4.696, P>0.30). The apoptosis of adenocarcinoma was significantly different with different histological response (F=7.73, P 0.05) and for adenocarcinoma with different pathological stages (F=0.001376, P>0.05). Conclusion: As an effective and safe procedure, preoperative transcatheter intraarterial chemotherapy infusion achieves a significant histological response and apoptosis in colorectal adenocarcinoma

  8. DEVELOPMENT OF DOMESTIC INFUSION DRUGS BASED ON PARACETAMOL

    Directory of Open Access Journals (Sweden)

    Almakaeva L.G.

    2016-06-01

    Full Text Available The intravenous form of paracetamol compared with oral more reliably supports effective drug concentration in blood plasma that promotes a higher therapeutic effect. Recent studies have confirmed that the use of the intravenous form of paracetamol to deal with postoperative pain multimodal analgesia modes results in reducing the frequency and quantity of opioids administered , and, as a consequence, its associated side effects. The drug Paracetamol , infusion solution 10 mg / ml to 100 ml glass bottles is a drug - generic . His qualitative and quantitative composition is developed from the study of literature data about the drug - similar to " Perfalhan , 10 mg / ml solution for infusion in 100 mL " company Bristol - Myers Squibb, France and experimental work. The aim of our study is development and support of the national composition of the infusion of the drug on the basis of paracetamol, selection of excipients that provide stability of the active substances. Materials and methods. The object of the study was the substance of paracetamol manufactured by Zhejiang Kangle Pharmaceutical Co. , Ltd, China. During the work conducted qualitative and quantitative monitoring sample preparation for indicators of stability: pH content of the active ingredient , transparency, color, impurities , contamination by the methods described in the SFU [and nor- ral documentation to the drug . One potential factor of instability is the effect of paracetamol oxygen, due to the presence in the molecule of paracetamol and -NH possibility of oxidation. Results and Discussion. Paracetamol is derived atsetamina . Substance acetylation are p - aminophenol with acetic anhydride . Saturated aqueous solution has a pH of paracetamol - ment about 6 . Paracetamol is a crystalline white powder , sparingly soluble in water, soluble in 96% alcohol, very slightly soluble in metilenhloride . . Active substance enters in comparison drug in the concentration of 10 mg/ml. Stable

  9. Crural Amputation of a Newborn as a Consequence of Intraosseous Needle Insertion and Calcium Infusion

    DEFF Research Database (Denmark)

    Oesterlie, Gorm Erlend; Petersen, Klaus Kjaer; Knudsen, Lars

    2014-01-01

    Intraosseous needle insertion and infusion is considered an easy and reliable method of achieving a vascular access in acute circulatory collapse where other methods have not been successful within reasonable time. Complications are considered few but may be serious. We present a case of a newborn...... girl, where intraosseous cannulation of the tibia was lifesaving. Despite following most standard recommendations, the treatment resulted in transtibial amputation due to necrosis. We suspect that the necrosis was a consequence of extravasation of tissue-toxic calcium infusion....

  10. Clinical nursing of pelvic neoplasm treated with infusion chemotherapy by using an anti-reflux arterial port-catheter system

    International Nuclear Information System (INIS)

    Xing Li; Yuan Chanjuan

    2011-01-01

    Objective: To discuss the clinical nursing care for patients with pelvic neoplasm who were treated with infusion chemotherapy by using an anti-reflux arterial port-catheter system. Methods: After the implantation of an anti-reflux arterial port-catheter system was successfully completed, intra-arterial infusion chemotherapy was carried out in 17 patients with pelvic neoplasm and the infusion chemotherapy was repeated for several times. The pre-procedural clinical nursing care was well done and the technique of proper placement was well grasped. The side effects of chemotherapy drugs and complications were dealt with in time. Medical orientation at discharge time included the protection methods for port-catheter system. Results: Seventeen patients received infusion chemotherapy successfully several times (ranged from 3 to 8 times) with a scheduled regular interval time. No severe complications occurred. No catheter leakage nor obvious irritation and compression symptoms of local skin developed during infusion period. Of the 17 patients, 6 had a complete response, 9 achieved a partial response, while the remaining 2 failed to respond. Conclusion: In accordance with characteristics of infusion chemotherapy by using an anti-reflux arterial port-catheter system, the reasonable and effective nursing care is important to guarantee the achievement of a successful performance and a satisfactory therapeutic result. (authors)

  11. Hybrid Vortex Method for the Aerodynamic Analysis of Wind Turbine

    Directory of Open Access Journals (Sweden)

    Hao Hu

    2015-01-01

    Full Text Available The hybrid vortex method, in which vortex panel method is combined with the viscous-vortex particle method (HPVP, was established to model the wind turbine aerodynamic and relevant numerical procedure program was developed to solve flow equations. The panel method was used to calculate the blade surface vortex sheets and the vortex particle method was employed to simulate the blade wake vortices. As a result of numerical calculations on the flow over a wind turbine, the HPVP method shows significant advantages in accuracy and less computation resource consuming. The validation of the aerodynamic parameters against Phase VI wind turbine experimental data is performed, which shows reasonable agreement.

  12. Comparative Evaluation of Biofunctional Compounds Content from Different Herbal Infusions

    Directory of Open Access Journals (Sweden)

    Anca C. Fărcaş

    2015-11-01

    Full Text Available Tea is the most important non-alcoholic beverage in the world being appreciated for its stimulant properties and health benefits. The aim of the present study was to evaluate the content in caffeine, phenolic compounds, flavonoids, as well as the antioxidant activity of five different herbal infusion samples in oder to compare the amount of these bioactive compounds from traditional Romanian medicinal plants and Chinese tea plants. Green tea, black tea, linden (lime tea, mint, and St. John's wort were chosen as materials for the preparation of infusion and laboratory analyses. The caffeine was extracted with dichloromethane and then was quantified by measuring the absorbance of the extract at 260 nm. The quantification of total phenolic compounds was achieved by Folin-Ciocalteu method, while the flavonoid content was determined using a chromogenic system of NaNO2-(Al(NO33-NaOH based on spectrophotometric method. The antioxidant capacity of each tea sample was assessed by evaluating their radical scavenging  activity on DPPH radical. The largest content in antioxidant compounds was found in green, but also in the mint infusion sample, while black tea has registered the highest caffeine content. Following the results obtained it can be stated that all the analysed samples contain remarkable amounts of biologically active compounds essential for the human body healt.

  13. Assessment of cerebrospinal fluid system dynamics : novel infusion protocol, mathematical modelling and parameter estimation for hydrocephalus investigations

    OpenAIRE

    Andersson, Kennet

    2011-01-01

    Patients with idiopathic normal pressure hydrocephalus (INPH) have a disturbance in the cerebrospinal fluid (CSF) system. The treatment is neurosurgical – a shunt is placed in the CSF system. The infusion test is used to assess CSF system dynamics and to aid in the selection of patients that will benefit from shunt surgery. The infusion test can be divided into three parts: a mathematical model, an infusion protocol and a parameter estimation method. A non-linear differential equation is used...

  14. Iodine-infused aeration for hull fouling prevention: a vessel-scale study.

    Science.gov (United States)

    Dickenson, Natasha C; Krumholz, Jason S; Hunsucker, Kelli Z; Radicone, Michael

    2017-11-01

    Biofouling is a significant economic and ecological problem, causing reduced vessel performance and increases in fuel consumption and emissions. Previous research has shown iodine vapor (I 2 )-infused aeration to be an environmentally friendly method for deterring the settlement of fouling organisms. An aeration system was deployed on a vessel with hull sections coated with two types of antifoulant coatings, Intersleek ® 1100 (fouling-release) and Interspeed ® BRA-640 (ablative copper biocide), as well as an inert epoxy barrier coating, to assess the effectiveness of aeration in conjunction with common marine coatings. I 2 -infused aeration resulted in consistent reductions of 80-90% in hard fouling across all three coatings. Additionally, aeration reduced the soft fouling rate by 45-70% when used in conjunction with both Intersleek ® and Interspeed ® BRA versus those coatings alone. The results of this study highlight the contribution of I 2 -infused aeration as a standalone mechanism for fouling prevention or as a complement to traditional antifouling coatings.

  15. Guide to intra-arterial infusion chemotherapy for pancreatic cancers (draft text)

    International Nuclear Information System (INIS)

    2012-01-01

    Pancreatic cancer is one of most malignant solid tumors. Trans-arterial infusion chemotherapy has been used for the inoperable pancreatic cancers. The local drug concentration in intra-arterial infusion chemotherapy is much higher than that in intravenous chemotherapy. Thus, a better therapeutic effect can be surely achieved, the disease-related symptoms can be well improved, the patient's survival time can be markedly prolonged, and the liver metastases can be effectively reduced. This paper aims to suggest a more detailed and standardized therapeutic scheme to perform intra-arterial infusion chemotherapy for inoperable pancreatic cancers, focusing on the relevant concept, contraindications, indications, preoperative preparation, methods of operation, postoperative treatment, the prevention and treatment of complications, etc. The scheme will help domestic interventional physicians to make reasonable decisions in their clinical practice. Of course, the scheme proposed here is not a mandatory standard, and it can not resolve all the problems which might be encountered in employing intra-arterial infusion chemotherapy for patients with inoperable pancreatic cancer. Therefore, the interventional physicians should fully understand the most useful medical evidence of a given patient and sincerely take the patient's own will into consideration before an individualized and reasonable therapeutic plan is able to be worked out. (authors)

  16. Impact of Computerized Order Entry to Pharmacy Interface on Order-Infusion Pump Discrepancies

    Directory of Open Access Journals (Sweden)

    Rebecca A. Russell

    2015-01-01

    Full Text Available Background. The ability of safety technologies to decrease errors, harm, and risk to patients has yet to be demonstrated consistently. Objective. To compare discrepancies between medication and intravenous fluid (IVF orders and bedside infusion pump settings within a pediatric intensive care unit (PICU before and after implementation of an interface between computerized physician order entry (CPOE and pharmacy systems. Methods. Within a 72-bed PICU, medication and IVF orders in the CPOE system and bedside infusion pump settings were collected. Rates of discrepancy were calculated and categorized by type. Results were compared to a study conducted prior to interface implementation. Expansion of PICU also occurred between study periods. Results. Of 455 observations, discrepancy rate decreased for IVF (p=0.01 compared to previous study. Overall discrepancy rate for medications was unchanged; however, medications infusing without an order decreased (p<0.01, and orders without corresponding infusion increased (p<0.05. Conclusions. Following implementation of an interface between CPOE and pharmacy systems, fewer discrepancies between IVF orders and infusion pump settings were observed. Discrepancies for medications did not change, and some types of discrepancies increased. In addition to interface implementation, changes in healthcare delivery and workflow related to ICU expansion contributed to observed changes.

  17. General remarks on advance remote infusion of water in a Campine colliery

    Energy Technology Data Exchange (ETDEWEB)

    Neels, P V [Institut d' Hygiene des Mines, Hasselt, Belgium; Degueldre, G

    1973-06-01

    This paper describes the application of the process of advance remote infusion of water into about ten panels at the Zolder, Holland coal mine to control dust. Tests show that the method, where applicable, will ensure a real and economical prevention of dust in the face, which is completely independent of the mining cycle and of the rate of advance of the workings, and which at the same time needs less water. Advance remote infusion is also found to increase the safety of working conditions by slowing down the emission of mine gas. 10 references.

  18. Functional efficiency comparison between split- and parallel-hybrid using advanced energy flow analysis methods

    Energy Technology Data Exchange (ETDEWEB)

    Guttenberg, Philipp; Lin, Mengyan [Romax Technology, Nottingham (United Kingdom)

    2009-07-01

    The following paper presents a comparative efficiency analysis of the Toyota Prius versus the Honda Insight using advanced Energy Flow Analysis methods. The sample study shows that even very different hybrid concepts like a split- and a parallel-hybrid can be compared in a high level of detail and demonstrates the benefit showing exemplary results. (orig.)

  19. Sequencing of megabase plus DNA by hybridization: Method development ENT. Final technical progress report

    Energy Technology Data Exchange (ETDEWEB)

    Crkvenjakov, R.; Drmanac, R.

    1991-01-31

    Sequencing by hybridization (SBH) is the only sequencing method based on the experimental determination of the content of oligonucleotide sequences. The data acquisition relies on the natural process of base pairing. It is possible to determine the content of complementary oligosequences in the target DNA by the process of hybridization with oligonucleotide probes of known sequences.

  20. Lipolytic response to glucose infusion in human subjects

    International Nuclear Information System (INIS)

    Wolfe, R.R.; Peters, E.J.

    1987-01-01

    The authors have determined the effect of various rates of glucose infusion on the rates of release of glycerol (R/sub a/ glycerol), free fatty acids (R/sub a/ FFA), and on energy metabolism in normal human volunteers. Plasma kinetics were determined with use of the stable isotopic tracers D-5-glycerol and [1- 13 C]palmitate, and energy metabolism was determined by indirect calorimetry. The effect of glucose infusion on R/sub a/ glycerol and R/sub a/ FFA was dose-dependent. At 4 mg x kg -1 x min -1 , both R/sub a/ glycerol and R/sub a/ FFA were suppressed; at 8 mg x kg -1 x min -1 , R/sub a/ FFA was even more depressed, but R/sub a/ glycerol was similar to the value during the 4 mg x kg -1 x min -1 infusion. At all infusion rates tested, the amount of potential energy available from the sum of the glucose infusion and endogenously mobilized fat was always greater than when no glucose was infused. Glucose decreased fat mobilization by both inhibiting lipolysis and stimulating reesterification, thus causing a significant increase in triglyceride-fatty acid substrate cycling within the adipose tissue. Plasma insulin was determined by radioimmunoassay

  1. Evaluation of free radical scavenging activity of tea infusion of commercial tea products available in uae

    International Nuclear Information System (INIS)

    Nessa, F.; Khan, S.A.

    2014-01-01

    In the present study, twenty four commercial tea samples were assayed to determine their free radical scavenging activity and polyphenolic contents based on the brewing/infusing period. Tea samples were infused/brewed in 200 mL boiled water at 120 degree C for 1, 2 and 5 min, respectively. The radical scavenging activities of tea infusion/brewing were measured using 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) assay method. The results were ranged from 67.81-90.51% for black tea bags, 90.37-94.51% for green tea bags, 24.66-92.25% for black tea powder, 16.08-93.06% for green tea powder and 32.90- 45.54% for Camomile herbal infusion. The results showed that 1 or 2 min black tea bags infusion exhibited highest radical scavenging activity than 5 min infusion. Antioxidant activities of tea powders were variable with the amount of tea powder. It was observed that antioxidant activity increased with increasing boiling time for smaller amount of sample. In contrary, shorter boiling time was better for larger amount of sample. The polyphenol contents of tea infusion were determined and the results were expressed as milligram quercetin equivalent/200 mL of tea infusion. The polyphenol content was increased with increased brewing period. In contrary, brewing for longer time rendered extract less antiradical activity. This study suggests that infusing tea bag for 1 or 2 min is sufficient for getting infusion with maximum radical scavenging activity and in case of tea powder, shorter boiling time is better for larger amount of powder or small amount of powder should be boiled for minimum 5 min for rendering extract with maximum radical scavenging activity. (author)

  2. Effects of Psidium guajava Leaf Infusion on Streptococci viridans

    Directory of Open Access Journals (Sweden)

    Hing Yi Chen

    2016-09-01

    Full Text Available Background: Dental caries is recognized as the most important oral burden. It is caused by the formation of lactate acid formed through reaction of bacteria and carbohydrates. Streptococci viridans has been proven as the primary etiologic agents for dental caries. Low accessibility in oral care services leads the Indonesian community to use plants in order to prevent dental caries. One of those plants is Psidium guajava (pink guava. The leaves were suggested to have antimicrobial effects on some gram-positive bacteria. When the organism is resistant to specific substance tested on media, a circular/inhibition zone around a disc containing antimicrobial substance was formed. The purpose of this study was to identify the presence of inhibition zones by infusion of Psidium guajava leaf on Streptococci viridians in vitro. Methods: This laboratory experiment was carried out in September to October 2014 at the Microbiology Laboratory, Faculty of Medicine, Universitas Padjadjaran. Infusions of Psidium guajava leaf were made into four different concentrations (10%, 25%, 50% and 100%, respectively and the identification of inhibition zones on Streptococci viridans obtained from the laboratory was tested using modified disk diffusion test. Distilled water acted as negative control. The results were then interpreted after 24 hours of incubation. Every procedure was repeated three times. Results: All four concentrations of Psidium guajava leaf infusions have formed inhibition zones on the media, with the highest concentration (100% producing largest average diameter. Conclusions: The infusion of Psidium guajava leaf produces inhibition zones on Streptococci virdans in vitro.

  3. Continuous indomethacin infusion may be less effective than bolus infusions for ductal closure in very low birth weight infants

    NARCIS (Netherlands)

    de Vries, NKS; Jagroep, FK; Jaarsma, AS; Elzenga, NJ; Bos, AF

    The effectiveness of continuous indomethacin (INDO) infusion versus bolus infusions for closure of patent ductus arteriosus (PDA) was investigated. The study design was an open-label case series (continuous INDO) with historic controls matched for gestational age (bolus INDO). Ductal closure rates

  4. Vocal fold submucosal infusion technique in phonomicrosurgery.

    Science.gov (United States)

    Kass, E S; Hillman, R E; Zeitels, S M

    1996-05-01

    Phonomicrosurgery is optimized by maximally preserving the vocal fold's layered microstructure (laminae propriae). The technique of submucosal infusion of saline and epinephrine into the superficial lamina propria (SLP) was examined to delineate how, when, and why it was helpful toward this surgical goal. A retrospective review revealed that the submucosal infusion technique was used to enhance the surgery in 75 of 152 vocal fold procedures that were performed over the last 2 years. The vocal fold epithelium was noted to be adherent to the vocal ligament in 29 of the 75 cases: 19 from previous surgical scarring, 4 from cancer, 3 from sulcus vocalis, 2 from chronic hemorrhage, and 1 from radiotherapy. The submucosal infusion technique was most helpful when the vocal fold epithelium required resection and/or when extensive dissection in the SLP was necessary. The infusion enhanced the surgery by vasoconstriction of the microvasculature in the SLP, which improved visualization during cold-instrument tangential dissection. Improved visualization facilitated maximal preservation of the SLP, which is necessary for optimal pliability of the overlying epithelium. The infusion also improved the placement of incisions at the perimeter of benign, premalignant, and malignant lesions, and thereby helped preserve epithelium uninvolved by the disorder.

  5. Effect of natural fibers and bio-resins on mechanical properties in hybrid and non-hybrid composites

    Science.gov (United States)

    Fragassa, Cristiano

    2016-05-01

    The aim of the present experimental investigation was to perform a comparative analysis concerning the influence on mechanical properties of natural fibers and/or bio-resins in reinforced thermoset composites. Flax and basalt fibers were selected as natural reinforcements, as single constituents or in hybrid combination. Glass synthetic fibers were used for comparison. Eco-friendly matrixes, both epoxy or vinylester, were considered and compared with composites based on traditional resins. Samples were fabricated by hand lay-up and resin infusion techniques. Cures were accelerated and controlled by applying heat and pressure in autoclave. Tensile, flexural and impact tests were carried out according to ASTM standards.

  6. Supervised segmentation of phenotype descriptions for the human skeletal phenome using hybrid methods.

    Science.gov (United States)

    Groza, Tudor; Hunter, Jane; Zankl, Andreas

    2012-10-15

    Over the course of the last few years there has been a significant amount of research performed on ontology-based formalization of phenotype descriptions. In order to fully capture the intrinsic value and knowledge expressed within them, we need to take advantage of their inner structure, which implicitly combines qualities and anatomical entities. The first step in this process is the segmentation of the phenotype descriptions into their atomic elements. We present a two-phase hybrid segmentation method that combines a series individual classifiers using different aggregation schemes (set operations and simple majority voting). The approach is tested on a corpus comprised of skeletal phenotype descriptions emerged from the Human Phenotype Ontology. Experimental results show that the best hybrid method achieves an F-Score of 97.05% in the first phase and F-Scores of 97.16% / 94.50% in the second phase. The performance of the initial segmentation of anatomical entities and qualities (phase I) is not affected by the presence / absence of external resources, such as domain dictionaries. From a generic perspective, hybrid methods may not always improve the segmentation accuracy as they are heavily dependent on the goal and data characteristics.

  7. SFC Optimization for Aero Engine Based on Hybrid GA-SQP Method

    Science.gov (United States)

    Li, Jie; Fan, Ding; Sreeram, Victor

    2013-12-01

    This study focuses on on-line specific fuel consumption (SFC) optimization of aero engines. For solving this optimization problem, a nonlinear pneumatic and thermodynamics model of the aero engine is built and a hybrid optimization technique which is formed by combining the genetic algorithm (GA) and the sequential quadratic programming (SQP) is presented. The ability of standard GA and standard SQP in solving this type of problem is investigated. It has been found that, although the SQP is fast, very little SFC reductions can be obtained. The GA is able to solve the problem well but a lot of computational time is needed. The presented hybrid GA-SQP gives a good SFC optimization effect and saves 76.6% computational time when compared to the standard GA. It has been shown that the hybrid GA-SQP is a more effective and higher real-time method for SFC on-line optimization of the aero engine.

  8. Application of the X-in-the-Loop Testing Method in the FCV Hybrid Degree Test

    Directory of Open Access Journals (Sweden)

    Haiyu Gao

    2018-02-01

    Full Text Available With the development of fuel cell vehicle technology, an effective testing method that can be applied to develop and verify the fuel cell vehicle powertrain system is urgently required. This paper presents the X-in-the-Loop (XiL testing method in the fuel cell vehicle (FCV hybrid degree test to resolve the first and key issues for the powertrain system design, and the test process and scenarios were designed. The hybrid degree is redefined into the static hybrid degree for system architecture design and the dynamic hybrid degree for vehicle control strategy design, and an integrated testing platform was introduced and a testing application was implemented by following the designed testing flowchart with two loops. Experimental validations show that the sizing of the FCE (Fuel Cell Engine, battery pack, and traction motor with the powertrain architecture can be determined, the control strategy can be evaluated seamlessly, and a systematic powertrain testing solution can be achieved through the whole development process. This research has developed a new testing platform and proposed a novel testing method on the fuel cell vehicle powertrain system, which will be a contribution to fuel cell vehicle technology and its industrialization.

  9. Web-enhanced Curricular Infusion of ESOL Competencies in Initial Teacher Certification Programs

    Directory of Open Access Journals (Sweden)

    Karen Wolz Verkler

    2003-09-01

    Full Text Available As the cultural and linguistic diversity continues to increase in Florida s K-12 public school population, the demand for teachers trained to address their unique needs becomes paramount. Previously a responsibility of Florida s school districts, ESOL(English for Speakers of Other Languages training has been delegated to colleges of education per state mandate. This mandate requires that graduates of initial teacher certification programs in the state s universities demonstrate competency in all of the 25 Florida Performance Standards for Teachers of English for Speakers of Other Languages. In order to satisfy this charge, colleges of education in Florida are following a variety of training models: stand-alone courses, curricular infusion, or a combination of the two. A large, metropolitan university in Central Florida has developed an integrated model consisting of two stand-alone courses, field experience integration of the standards, and curricular infusion of ESOL standards via on-lone modules in methods courses. The authors, who teach methods courses in which such infusion has been recently effected, surveyed their students to obtain feedback regarding the modules, the results of which are discussed in this paper.

  10. The Investigation for Antifungal Effect of Medicinal Plants, Combination Infusion of Piper Bettle Leaves, Punica Granatum Fructus Cortec, Curcuma Domestica Rhizome

    Directory of Open Access Journals (Sweden)

    Berna Elya

    2002-12-01

    Full Text Available The tested demartophyta used Candida albicans. This research using dilution method to determine of minimum inhibitory concentration (MIC and difusion method to determine zone inhibition around of disc. The results of determination of MIC showed that combination infusion Piper bettle leaves with Punica granatum Fructus Cortex against C. albicans respectively, 31,2 mg/ml : 7,8 mg/ml; 15,6 mg/ml : 15,6 mg/ml and 7,8 mg/ml : 31,2 mg/ml. The determination for zone inhibition from 3 concentration of infusion of Piper bettle leaves with 3 concentration of Punica granatum Fructus Cortex with 9 combination against C. albicans showed that combination of two infusion is the larger than the single infusion.

  11. Improving the technique of water infusion to control dust in the mines of the central district of the Donetz coalfield

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, S N

    1974-03-01

    A study of the results obtained with different methods of water infusion is followed by an account of a new ''pinpoint'' infusion technique utilizing rising infusion holes of limited depth (20-25 m). This new technique enhances safety of work at the coal face, since it avoids deterioraon of the face due to erosion of surrounding walls and accumulation of gas in the infusion holes; it also renders the arduous job of guided drilling and sealing of the holes unnecessary, and facilitates coal-getting and development work.

  12. Topology optimization of bounded acoustic problems using the hybrid finite element-wave based method

    DEFF Research Database (Denmark)

    Goo, Seongyeol; Wang, Semyung; Kook, Junghwan

    2017-01-01

    This paper presents an alternative topology optimization method for bounded acoustic problems that uses the hybrid finite element-wave based method (FE-WBM). The conventional method for the topology optimization of bounded acoustic problems is based on the finite element method (FEM), which...

  13. GeoNeoLogical novel and other hybrimedia experiments: or how to use hybrid methods such as Hybrid Discourse Analysis (HDA within a knowledge base

    Directory of Open Access Journals (Sweden)

    Andrade, Pedro

    2016-07-01

    Full Text Available In this essay I will present some results of the project Public Communication of Art, which developed a seminal theory and methodology intended to cope with hybridity and new media literacy in our globalized and inter/transcultural world. Some of the methods used blend vision with touch and are called ‘hybrid methods’ or ‘hybrimethods’. Examples of these are, for instance, a Multitouch Interactive Table, a Multitouch Questionnaire, Trichotomies Game and GeoNeoLogic Novel, this last one being a hybrid novel activated by fusion of vision, touch and GPS coordinates. Another hybrimethod is a sort of discursive analysis, named Hybrid Discourse Analysis (HDA, which uses ‘semantic-logical networks’ organized by concepts and ‘relation-concepts’. HDA is here articulated with Critical Sociology and applied to the analysis of a text on Magic Realism, which is also a hybrid genre within the social field of literature.

  14. A naturalistic glyceryl trinitrate infusion migraine model in the rat

    DEFF Research Database (Denmark)

    Ramachandran, Roshni; Bhatt, Deepak Kumar; Ploug, Kenneth Beri

    2012-01-01

    Glyceryl trinitrate (GTN) infusion is a reliable method to provoke migraine-like headaches in humans. Previous studies have simulated this human model in anaesthetized or in awake rodents using GTN doses 10,000 times higher than used in humans. The relevance of such toxicological doses to migraine...

  15. Is cerebral oxygenation negatively affected by infusion of norepinephrine in healthy subjects?

    DEFF Research Database (Denmark)

    Brassard, P.; Seifert, T.; Secher, Niels H.

    2009-01-01

    BACKGROUND: Vasopressor agents are commonly used to increase mean arterial pressure (MAP) in order to secure a pressure gradient to perfuse vital organs. The influence of norepinephrine on cerebral oxygenation is not clear. The aim of this study was to evaluate the impact of the infusion of norep......BACKGROUND: Vasopressor agents are commonly used to increase mean arterial pressure (MAP) in order to secure a pressure gradient to perfuse vital organs. The influence of norepinephrine on cerebral oxygenation is not clear. The aim of this study was to evaluate the impact of the infusion...... of norepinephrine on cerebral oxygenation in healthy subjects. METHODS: Three doses of norepinephrine (0.05, 0.1, and 0.15 microg kg(-1) min(-1) for 20 min each) were infused in nine healthy subjects [six males; 26 (6) yr, mean (SD)]. MAP, cerebral oxygenation characterized by frontal lobe oxygenation (Sc(O2...

  16. Hybrid finite element and Brownian dynamics method for charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Gary A., E-mail: ghuber@ucsd.edu; Miao, Yinglong [Howard Hughes Medical Institute, University of California San Diego, La Jolla, California 92093-0365 (United States); Zhou, Shenggao [Department of Mathematics and Mathematical Center for Interdiscipline Research, Soochow University, 1 Shizi Street, Suzhou, 215006 Jiangsu (China); Li, Bo [Department of Mathematics and Quantitative Biology Graduate Program, University of California, San Diego, 9500 Gilman Drive, La Jolla, California 92093-0112 (United States); McCammon, J. Andrew [Howard Hughes Medical Institute, University of California San Diego, La Jolla, California 92093 (United States); Department of Chemistry and Biochemistry, University of California San Diego, La Jolla, California 92093-0365 (United States); Department of Pharmacology, University of California San Diego, La Jolla, California 92093-0636 (United States)

    2016-04-28

    Diffusion is often the rate-determining step in many biological processes. Currently, the two main computational methods for studying diffusion are stochastic methods, such as Brownian dynamics, and continuum methods, such as the finite element method. A previous study introduced a new hybrid diffusion method that couples the strengths of each of these two methods, but was limited by the lack of interactions among the particles; the force on each particle had to be from an external field. This study further develops the method to allow charged particles. The method is derived for a general multidimensional system and is presented using a basic test case for a one-dimensional linear system with one charged species and a radially symmetric system with three charged species.

  17. THE INFLUENCE OF HELICHRYSUM ARENARIUM FLOWERS INFUSION ON MAST CELLS DEGRANULATION IN VITRO

    Directory of Open Access Journals (Sweden)

    N. V. Karazhan

    2018-01-01

    Full Text Available Helichrysum arenarium flowers are medical plant raw materials with a high concentration of flavonoids (2.5– 5.0%. As compounds of this group of biologically active substances often possess antiallergic activity, Helichrysum arenarium flowers are a potential antiallergic medicine. The aim is to study an antiallergic activity of Helichrysum arenarium flowers infusion on the model of mast cells degranulation in vitro. Materials and methods. Helichrysum arenarium flowers infusion was made in accordance with the requirements of the State Pharmacopoeia of the Republic of Belarus. Mast cells were obtained from the abdominal cavity of inbred mice weighing 20–25 g. Experimental animals were divided into three groups of 5 individuals in each. The intact group was not subjected to any manipulation for 14 days. The test group was sensitized with the epidermal allergen from the cat’s fur. The placebo group was subjected to the same manipulations as the test group, by phosphate buffered saline pH 7.4 for sensitization instead of the allergen. Results and discussion. The addition of Helichrysum arenarium flowers infusion to the mast cells of the intact group and the placebo group did not affect the percentage of the mast cells degranulation (p>0.05, indicating that the animals of the intact group and the placebo group did not have a hypersensitivity to the components of the medicine under investigation. In the presence of Helichrysum arenarium flowers the percentage of the mast cells degranulation of the test group decreased in comparison with the percentage of the mast cells degranulation in the presence of the allergen from 23.6±2.1% to 8.1–16.2% (p<0.05. Semi-effective concentration of Helichrysum arenarium flowers infusion was 1.33±0.04 mg / ml. The stabilizing effect on the mast cells degranulation of the Helichrysum arenarium flowers infusion was statistically significantly lower than the stabilizing effect of the Bidens tripartita herb

  18. Rotator cuff healing after continuous subacromial bupivacaine infusion: an in vivo rabbit study

    Science.gov (United States)

    FRIEL, NICOLE A.; WANG, VINCENT M.; SLABAUGH, MARK A.; WANG, FANCHIA; CHUBINSKAYA, SUSAN; COLE, BRIAN J.

    2013-01-01

    Background The objective of this study was to evaluate the effects of continuous subacromial bupivacaine infusion on supraspinatus muscle and rotator cuff tendon healing via gross, biomechanical, and histologic analyses. Methods Thirty-three New Zealand White rabbits underwent unilateral supraspinatus transection and rotator cuff repair (RCR). Rabbits were assigned to 1 of 3 groups: (1)RCR only, (2)RCR with continuous saline infusion for 48 hours, or (3)RCR with continuous 0.25% bupivacaine with epinephrine (1:200,000) infusion for 48 hours. Rabbits were sacrificed at either 2 (for histologic assessment) or 8 weeks post-operatively (for biomechanical and histologic assessment). Results Tensile testing showed significantly higher load to failure in intact tendons compared to repaired tendons (pBupivacaine groups. Histologically, the enthesis of repaired tendons showed increased cellularity and disorganized collagen fibers compared to intact tendons, with no differences between treatment groups. Muscle histology demonstrated scattered degenerative muscle fibers at 2 weeks in both RCR Saline and RCR Bupivacaine, but no degeneration was noted at 8 weeks. Conclusions The healing supraspinatus tendons exposed to bupivacaine infusion showed similar histologic and biomechanical characteristics compared to untreated and saline infused RCR groups. Muscle histology showed fiber damage at 2 weeks for both the saline and bupivacaine treated groups, with no apparent disruption at 8 weeks, suggesting a recovery process. Therefore, subacromial bupivacaine infusion in this rabbit rotator cuff model does not appear to impair muscle or tendon following acute injury and repair. Level Of Evidence Basic science study PMID:22818894

  19. Coarse-graining and hybrid methods for efficient simulation of stochastic multi-scale models of tumour growth

    International Nuclear Information System (INIS)

    Cruz, Roberto de la; Guerrero, Pilar; Calvo, Juan; Alarcón, Tomás

    2017-01-01

    The development of hybrid methodologies is of current interest in both multi-scale modelling and stochastic reaction–diffusion systems regarding their applications to biology. We formulate a hybrid method for stochastic multi-scale models of cells populations that extends the remit of existing hybrid methods for reaction–diffusion systems. Such method is developed for a stochastic multi-scale model of tumour growth, i.e. population-dynamical models which account for the effects of intrinsic noise affecting both the number of cells and the intracellular dynamics. In order to formulate this method, we develop a coarse-grained approximation for both the full stochastic model and its mean-field limit. Such approximation involves averaging out the age-structure (which accounts for the multi-scale nature of the model) by assuming that the age distribution of the population settles onto equilibrium very fast. We then couple the coarse-grained mean-field model to the full stochastic multi-scale model. By doing so, within the mean-field region, we are neglecting noise in both cell numbers (population) and their birth rates (structure). This implies that, in addition to the issues that arise in stochastic-reaction diffusion systems, we need to account for the age-structure of the population when attempting to couple both descriptions. We exploit our coarse-graining model so that, within the mean-field region, the age-distribution is in equilibrium and we know its explicit form. This allows us to couple both domains consistently, as upon transference of cells from the mean-field to the stochastic region, we sample the equilibrium age distribution. Furthermore, our method allows us to investigate the effects of intracellular noise, i.e. fluctuations of the birth rate, on collective properties such as travelling wave velocity. We show that the combination of population and birth-rate noise gives rise to large fluctuations of the birth rate in the region at the leading edge

  20. Intravenous lidocaine infusion--a new treatment of chronic painful diabetic neuropathy?

    DEFF Research Database (Denmark)

    Kastrup, J; Petersen, P; Dejgård, A

    1987-01-01

    after lidocaine infusion compared to after saline infusion (P less than 0.05 and P less than 0.02, respectively). The duration of the individual effect ranged from 3 to 21 days. Lidocaine infusion had no effect on the objective measurements of neuropathy. Intravenous lidocaine infusion seems to be a new...

  1. A Hybrid Method for Modeling and Solving Supply Chain Optimization Problems with Soft and Logical Constraints

    Directory of Open Access Journals (Sweden)

    Paweł Sitek

    2016-01-01

    Full Text Available This paper presents a hybrid method for modeling and solving supply chain optimization problems with soft, hard, and logical constraints. Ability to implement soft and logical constraints is a very important functionality for supply chain optimization models. Such constraints are particularly useful for modeling problems resulting from commercial agreements, contracts, competition, technology, safety, and environmental conditions. Two programming and solving environments, mathematical programming (MP and constraint logic programming (CLP, were combined in the hybrid method. This integration, hybridization, and the adequate multidimensional transformation of the problem (as a presolving method helped to substantially reduce the search space of combinatorial models for supply chain optimization problems. The operation research MP and declarative CLP, where constraints are modeled in different ways and different solving procedures are implemented, were linked together to use the strengths of both. This approach is particularly important for the decision and combinatorial optimization models with the objective function and constraints, there are many decision variables, and these are summed (common in manufacturing, supply chain management, project management, and logistic problems. The ECLiPSe system with Eplex library was proposed to implement a hybrid method. Additionally, the proposed hybrid transformed model is compared with the MILP-Mixed Integer Linear Programming model on the same data instances. For illustrative models, its use allowed finding optimal solutions eight to one hundred times faster and reducing the size of the combinatorial problem to a significant extent.

  2. A modified hybrid uncertain analysis method for dynamic response field of the LSOAAC with random and interval parameters

    Science.gov (United States)

    Zi, Bin; Zhou, Bin

    2016-07-01

    For the prediction of dynamic response field of the luffing system of an automobile crane (LSOAAC) with random and interval parameters, a hybrid uncertain model is introduced. In the hybrid uncertain model, the parameters with certain probability distribution are modeled as random variables, whereas, the parameters with lower and upper bounds are modeled as interval variables instead of given precise values. Based on the hybrid uncertain model, the hybrid uncertain dynamic response equilibrium equation, in which different random and interval parameters are simultaneously included in input and output terms, is constructed. Then a modified hybrid uncertain analysis method (MHUAM) is proposed. In the MHUAM, based on random interval perturbation method, the first-order Taylor series expansion and the first-order Neumann series, the dynamic response expression of the LSOAAC is developed. Moreover, the mathematical characteristics of extrema of bounds of dynamic response are determined by random interval moment method and monotonic analysis technique. Compared with the hybrid Monte Carlo method (HMCM) and interval perturbation method (IPM), numerical results show the feasibility and efficiency of the MHUAM for solving the hybrid LSOAAC problems. The effects of different uncertain models and parameters on the LSOAAC response field are also investigated deeply, and numerical results indicate that the impact made by the randomness in the thrust of the luffing cylinder F is larger than that made by the gravity of the weight in suspension Q . In addition, the impact made by the uncertainty in the displacement between the lower end of the lifting arm and the luffing cylinder a is larger than that made by the length of the lifting arm L .

  3. Evaluation of antioxidant capacity of Aidia borneensis leaf infusion, an endemic plant in Brunei Darussalam

    Directory of Open Access Journals (Sweden)

    Metussin, N.,

    2017-08-01

    Full Text Available We investigated the total antioxidant capacity of Aidia borneensis leaf infusion, a Bornean endemic plant, which is traditionally consumed as a home-remedy beverage in Brunei Darussalam. The antioxidant capacity of the infusion of A. borneensis leaves was evaluated by 2,2-diphenyl-1-picryhydrazyl (DPPH radical-scavenging ability. We found that the infusion shows a relatively high antioxidant capacity, and it was attributed to its high phenolic, flavonoid, and flavanol contents which were evaluated by Folin–Ciocalteu reagent, colorimetric assay, and aluminum chloride colorimetric method, respectively. By comparing its total antioxidant capacity, we estimated that the infusion of A. borneensis leaves is in the middle rank among twelve different commercially available Camellia sinensis teas. Our findings would have significant implications on A. borneensis products from Brunei Darussalam and on the feasibility of establishing this new beverage among the commercially available conventional C. sinensis and herbal teas.

  4. Hybrid electrokinetic method applied to mix contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Mansour, H.; Maria, E. [Dept. of Building Civil and Environmental Engineering, Concordia Univ., Montreal (Canada)

    2001-07-01

    Several industrials and municipal areas in North America are contaminated with heavy metals and petroleum products. This mix contamination presents a particularly difficult task for remediation when is exposed in clayey soil. The objective of this research was to find a method to cleanup mix contaminated clayey soils. Finally, a multifunctional hybrid electrokinetic method was investigated. Clayey soil was contaminated with lead and nickel (heavy metals) at the level of 1000 ppm and phenanthrene (PAH) of 600 ppm. Electrokinetic surfactant supply system was applied to mobilize, transport and removal of phenanthrene. A chelation agent (EDTA) was also electrokinetically supplied to mobilize heavy metals. The studies were performed on 8 lab scale electrokinetic cells. The mix contaminated clayey soil was subjected to DC total voltage gradient of 0.3 V/cm. Supplied liquids (surfactant and EDTA) were introduced in different periods of time (22 days, 42 days) in order to optimize the most excessive removal of contaminants. The ph, electrical parameters, volume supplied, and volume discharged was monitored continuously during each experiment. At the end of these tests soil and cathalyte were subjected to physico-chemical analysis. The paper discusses results of experiments including the optimal energy use, removal efficiency of phenanthrene, as well, transport and removal of heavy metals. The results of this study can be applied for in-situ hybrid electrokinetic technology to remediate clayey sites contaminated with petroleum product mixed with heavy metals (e.g. manufacture Gas Plant Sites). (orig.)

  5. Disinfection of Escherichia coli bacteria using hybrid method of ozonation and hydrodynamic cavitation with orifice plate

    Science.gov (United States)

    Karamah, Eva F.; Ghaudenson, Rioneli; Amalia, Fitri; Bismo, Setijo

    2017-11-01

    This research aims to evaluate the performance of hybrid method of ozonation and hydrodynamic cavitation with orifice plate on E.coli bacteria disinfection. In this research, ozone dose, circulation flowrate, and disinfection method were varied. Ozone was produced by commercial ozonator with ozone dose of 64.83 mg/hour, 108.18 mg/hour, and 135.04 mg/hour. Meanwhile, hydrodynamic cavitation was generated by an orifice plate. The disinfection method compared in this research were: hydrodynamic cavitation, ozonation, and the combination of both. The best result on each method was achieved on the 60th minutes and with a circulation flowrate of 7 L/min. The hybrid method attained final concentration of 0 CFU/mL from the initial concentration of 2.10 × 105 CFU/mL. The ozonation method attained final concentration of 0 CFU/mL from the initial concentration of 1.32 × 105 CFU/mL. Cavitation method gives the least disinfection with final concentration of 5.20 × 104 CFU/mL from the initial concentration of 2.17 × 105 CFU/mL. In conclusion, hybrid method gives a faster and better disinfection of E.coli than each method on its own.

  6. Incidence and management of infusion reactions to infliximab in 186 italian patient’s with rheumatoid arthritis: the Padua experience

    Directory of Open Access Journals (Sweden)

    S. Todesco

    2011-09-01

    Full Text Available Objective: We report the incidence and treatment of infusion reactions to infliximab, a chimeric monoclonal IgG1 antibody against tumor necrosis factor a, in a large cohort of patients with rheumatoid arthritis. Patients and methods: One hundred eighty six patients with rheumatoid arthritis treated with infliximab for a total of 216.6 patient years were retrospectively evaluated. Patients received 2160 infliximab infusions at the Division of Rheumatology at the University Hospital of Padua from May, 2000 to April, 2004. Specific treatment protocols for initial and subsequent acute infusion reactions were followed and the outcomes documented. Results: The overall incidence of infusion reactions to infliximab was 0.8% (19 out of 2160 of infusions, affecting 10.2% of patients (19 out of 186. Mild, moderate, or severe acute reactions occurred in 0.1% (3 of 2160, 0.6% (13 of 2160, and 0.04% (1 of 2160 of infliximab infusions, respectively. Delayed infusion reactions occurred in 0.09% (2 of 2160 of infusions. Use of specific treatment protocols resulted in rapid resolution of all acute reactions to infliximab. With a prophylaxis protocol, all patients who experienced an initial mild acute reaction were able to receive additional infusions. Conclusions: Using appropriate treatment protocols, infliximab infusion reactions were effectively treated and prevented in patients with mild acute reactions upon retreatment. In the case of moderate to severe infusion reactions, the risks and the benefits of the continuation of infliximab therapy need to be carefully considered.

  7. Hybrid perturbation methods based on statistical time series models

    Science.gov (United States)

    San-Juan, Juan Félix; San-Martín, Montserrat; Pérez, Iván; López, Rosario

    2016-04-01

    In this work we present a new methodology for orbit propagation, the hybrid perturbation theory, based on the combination of an integration method and a prediction technique. The former, which can be a numerical, analytical or semianalytical theory, generates an initial approximation that contains some inaccuracies derived from the fact that, in order to simplify the expressions and subsequent computations, not all the involved forces are taken into account and only low-order terms are considered, not to mention the fact that mathematical models of perturbations not always reproduce physical phenomena with absolute precision. The prediction technique, which can be based on either statistical time series models or computational intelligence methods, is aimed at modelling and reproducing missing dynamics in the previously integrated approximation. This combination results in the precision improvement of conventional numerical, analytical and semianalytical theories for determining the position and velocity of any artificial satellite or space debris object. In order to validate this methodology, we present a family of three hybrid orbit propagators formed by the combination of three different orders of approximation of an analytical theory and a statistical time series model, and analyse their capability to process the effect produced by the flattening of the Earth. The three considered analytical components are the integration of the Kepler problem, a first-order and a second-order analytical theories, whereas the prediction technique is the same in the three cases, namely an additive Holt-Winters method.

  8. Evaluation of integration methods for hybrid simulation of complex structural systems through collapse

    Science.gov (United States)

    Del Carpio R., Maikol; Hashemi, M. Javad; Mosqueda, Gilberto

    2017-10-01

    This study examines the performance of integration methods for hybrid simulation of large and complex structural systems in the context of structural collapse due to seismic excitations. The target application is not necessarily for real-time testing, but rather for models that involve large-scale physical sub-structures and highly nonlinear numerical models. Four case studies are presented and discussed. In the first case study, the accuracy of integration schemes including two widely used methods, namely, modified version of the implicit Newmark with fixed-number of iteration (iterative) and the operator-splitting (non-iterative) is examined through pure numerical simulations. The second case study presents the results of 10 hybrid simulations repeated with the two aforementioned integration methods considering various time steps and fixed-number of iterations for the iterative integration method. The physical sub-structure in these tests consists of a single-degree-of-freedom (SDOF) cantilever column with replaceable steel coupons that provides repeatable highlynonlinear behavior including fracture-type strength and stiffness degradations. In case study three, the implicit Newmark with fixed-number of iterations is applied for hybrid simulations of a 1:2 scale steel moment frame that includes a relatively complex nonlinear numerical substructure. Lastly, a more complex numerical substructure is considered by constructing a nonlinear computational model of a moment frame coupled to a hybrid model of a 1:2 scale steel gravity frame. The last two case studies are conducted on the same porotype structure and the selection of time steps and fixed number of iterations are closely examined in pre-test simulations. The generated unbalance forces is used as an index to track the equilibrium error and predict the accuracy and stability of the simulations.

  9. Study on the simultaneous determination of seven benzoylurea pesticides in Oolong tea and their leaching characteristics during infusing process by HPLC-MS/MS.

    Science.gov (United States)

    Chen, Lei; Chen, JinFa; Guo, Ying; Li, JianRong; Yang, YiQiang; Xu, LiangJun; Fu, FengFu

    2014-01-15

    A method for the simultaneous determination of 7 benzoylurea pesticides (chlorfluazuron, diflubenzuron, fluazuron, flufenoxuron, hexaflumuron, teflubenzuron and triflumuron) in the manufactured Oolong tea leaves and its infusion was described. The method has a LOD of 0.03-1.00ng/mL, a recovery of 90.4-103% for made tea and 90.3-102% for tea-infused liquid, respectively. By using the proposed method, the leaching characteristics of above 7 pesticides during infusing process were investigated. The experimental results revealed that: (1) diflubenzuron can be most easily extracted out during infusing process, followed by triflumuron, teflubenzuron, hexaflumuron, chlorfluazuron, flufenoxuron and fluazuron. (2) The leaching of flufenoxuron and chlorfluazuron during infusing process seems to be controlled by only their solubility, whereas, the leaching of other 5 benzoylurea insecticides was primarily controlled by their partitioning coefficient between made tea and hot water. The results of this study are helpful for the accurate evaluation of the safety of Oolong tea. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. ArtsIN: Arts Integration and Infusion Framework

    Science.gov (United States)

    Hartle, Lynn C.; Pinciotti, Patricia; Gorton, Rebecca L.

    2015-01-01

    Teaching to meet the diverse learning needs of twenty-first century, global learners can be challenging, yet a growing body of research points to the proved successes of arts-infused and integrated curricula, especially for building capacity for learning and motivation. This article presents the ArtsIN: Arts Integration and Infusion framework, a…

  11. Bupivacaine constant continuous surgical wound infusion versus continuous epidural infusion for post cesarean section pain, randomized placebo-controlled study

    Directory of Open Access Journals (Sweden)

    Hossam A. ELShamaa

    2016-10-01

    Conclusion: The current study demonstrated that bupivacaine administered by continuous epidural infusion provided a significantly lower pain scores with mobilization, and hence better analgesia for post cesarean section pain in the first postoperative day compared to continuous bupivacaine wound infusion through fenestrated catheter using the constant flow PainFusor system.

  12. Infusion of water into a coal mass, carried out at the mines of Houilleres du Bassin du Nord et du Pas-de-Calais

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    This paper reports on research work concerning water infusion in order to reduce dust danger at working face. It also describes development of the process since 1950; improvements to various low flow methods; and factors governing the choice of a process. Infusion can be carried out from working face, or from levels. The paper also describes hole drilling (equipment and methods used); fitting out holes (equipment, cementing); inspection; and non-stop infusion.

  13. Research on a Novel Exciting Method for a Sandwich Transducer Operating in Longitudinal-Bending Hybrid Modes

    Directory of Open Access Journals (Sweden)

    Yingxiang Liu

    2017-06-01

    Full Text Available A novel exciting method for a sandwich type piezoelectric transducer operating in longitudinal-bending hybrid vibration modes is proposed and discussed, in which the piezoelectric elements for the excitations of the longitudinal and bending vibrations share the same axial location, but correspond to different partitions. Whole-piece type piezoelectric plates with three separated partitions are used, in which the center partitions generate the first longitudinal vibration, while the upper and lower partitions produce the second bending vibration. Detailed comparisons between the proposed exciting method and the traditional one were accomplished by finite element method (FEM calculations, which were further verified by experiments. Compared with the traditional exciting method using independent longitudinal ceramics and bending ceramics, the proposed method achieves higher electromechanical coupling factors and larger vibration amplitudes, especially for the bending vibration mode. This novel exciting method for longitudinal-bending hybrid vibrations has not changed the structural dimensions of the sandwich transducer, but markedly improves the mechanical output ability, which makes it very helpful and meaningful in designing new piezoelectric actuators operated in longitudinal-bending hybrid vibration modes.

  14. Interior Noise Prediction of the Automobile Based on Hybrid FE-SEA Method

    Directory of Open Access Journals (Sweden)

    S. M. Chen

    2011-01-01

    created using hybrid FE-SEA method. The modal density was calculated using analytical method and finite element method; the damping loss factors of the structural and acoustic cavity subsystems were also calculated with analytical method; the coupling loss factors between structure and structure, structure and acoustic cavity were both calculated. Four different kinds of excitations including road excitations, engine mount excitations, sound radiation excitations of the engine, and wind excitations are exerted on the body of automobile when the automobile is running on the road. All the excitations were calculated using virtual prototype technology, computational fluid dynamics (CFD, and experiments realized in the design and development stage. The interior noise of the automobile was predicted and verified at speed of 120 km/h. The predicted and tested overall SPLs of the interior noise were 73.79 and 74.44 dB(A respectively. The comparison results also show that the prediction precision is satisfied, and the effectiveness and reliability of the hybrid FE-SEA model of the automobile is verified.

  15. Phytoconstituents and diuretic activity of Cymbopogon citratus leaf infusions in humans

    Directory of Open Access Journals (Sweden)

    Christopher Ekpenyong

    2014-09-01

    Full Text Available Objective: To assess the diuretic activity of infusions prepared from Cymbopogon citratus (C. citratus leaves in healthy volunteers. Methods: One hundred and five subjects (55 men and 50 women aged 18 to 35 years were randomly assigned to groups set to orally receive infusions prepared from 2, 4, or 8 g of C. citratus leaf powder, once daily for 30 d. Urine volume, frequency of urination, urine specific gravity, and plasma and urinary levels of electrolytes were assessed 1 day before (baseline, and at 10 and 30 d after initiation of treatment. Computed diuretic indices were compared between experimental and baseline values. Results: Subjects treated with infusions prepared from C. citratus leaf powder which tested positive for saponins, tannins, flavaniods, phenols, anthraquinones, alkaloids, and deoxy-sugar exhibited a significant increase in indices of diuresis including urine volume, urination frequency, diuretic action, natriuretic and saliuretic indices and renal fractional excretion of electrolytes and metabolic acidosis. A non-significant change in urine specific gravity was observed in all groups. eGFR showed a non-significant increase at Day 10, but decreased significantly (P<0.05 at Day 30. Thiazide and aldosterone secretion indices decreased at Day 10, whereas carbonic anhydrase index increased significantly (P<0.05 at both Days 10 and 30. Conclusions: These results indicate a loop active diuretic action of C. citratus infusion.

  16. Experimental intraperitoneal infusion of OK-432 in rats: Evaluation of peritoneal complications and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Wook [Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan (Korea, Republic of); Kim, Hak Jin, E-mail: hakjink@pusan.ac.k [Department of Radiology, Pusan National University Hospital, Pusan National University College of Medicine, Medical Research Institute, Busan (Korea, Republic of); Lee, Jun Woo [Department of Radiology, Pusan National University Hospital, Pusan National University College of Medicine, Medical Research Institute, Busan (Korea, Republic of)

    2010-06-15

    Purpose: OK-432 is known to be a potent sclerosant of cystic lesions. The purpose of this study was to evaluate both its safety and pathologic effects after the infusion of OK-432 into the peritoneal cavity of rats. Materials and methods: Twenty male rats were used in this study. Twelve rats were infused intraperitoneally with 0.2 Klinishe Einheit of OK-432 melted in 2 mL of normal saline (group 1: the treated group); four rats each were infused intraperitoneally with 0.5 mL of 99% ethanol (group 2) and normal saline (group 3), and served as the control groups. An abdominal ultrasonographic examination was performed both before and after the infusions in all rats. Three rats in group 1 and one rat in each of groups 2 and 3 were sacrificed each week following the infusion. Gross and microscopic evaluations of the peritoneum and abdominal cavity were performed on each rat. Results: In group 1, the abdomen was clear on gross inspection and the peritoneum was unremarkable on microscopic examination. In group 2, mild-to-moderate peritoneal adhesions were revealed grossly, and inflammation and fibrosis of the peritoneum were demonstrated microscopically. In group 3, no specific abnormalities were noted on gross or microscopic examinations. Conclusion: Leakage or abnormal infusion of OK-432 solution into the peritoneal cavity during sclerotherapy of intra-abdominal or retroperitoneal cystic lesions does not result in any significant complications.

  17. Experimental intraperitoneal infusion of OK-432 in rats: Evaluation of peritoneal complications and pathology

    International Nuclear Information System (INIS)

    Kim, Dong Wook; Kim, Hak Jin; Lee, Jun Woo

    2010-01-01

    Purpose: OK-432 is known to be a potent sclerosant of cystic lesions. The purpose of this study was to evaluate both its safety and pathologic effects after the infusion of OK-432 into the peritoneal cavity of rats. Materials and methods: Twenty male rats were used in this study. Twelve rats were infused intraperitoneally with 0.2 Klinishe Einheit of OK-432 melted in 2 mL of normal saline (group 1: the treated group); four rats each were infused intraperitoneally with 0.5 mL of 99% ethanol (group 2) and normal saline (group 3), and served as the control groups. An abdominal ultrasonographic examination was performed both before and after the infusions in all rats. Three rats in group 1 and one rat in each of groups 2 and 3 were sacrificed each week following the infusion. Gross and microscopic evaluations of the peritoneum and abdominal cavity were performed on each rat. Results: In group 1, the abdomen was clear on gross inspection and the peritoneum was unremarkable on microscopic examination. In group 2, mild-to-moderate peritoneal adhesions were revealed grossly, and inflammation and fibrosis of the peritoneum were demonstrated microscopically. In group 3, no specific abnormalities were noted on gross or microscopic examinations. Conclusion: Leakage or abnormal infusion of OK-432 solution into the peritoneal cavity during sclerotherapy of intra-abdominal or retroperitoneal cystic lesions does not result in any significant complications.

  18. Continuous infusion of chemotherapy: focus on 5-fluorouracil and fluorodeoxyuridine

    NARCIS (Netherlands)

    Poorter, R. L.; Bakker, P. J.; Veenhof, C. H.

    1998-01-01

    Continuous infusion of chemotherapy is one of the developments to try to improve the treatment of metastatic cancer. There is a sound theoretical rationale to deliver cytotoxic drugs as a continuous infusion. Furthermore, the development of reliable venous access devices and portable infusion pumps

  19. Effects of intra-arterial infusion therapy or systemic chemotherapy with docetaxel for VX2 tumor in rabbit hind limb

    International Nuclear Information System (INIS)

    Qian Yuanxin; Wu Xiaomei; He Miao; Liu Tao; Deng Duo

    2010-01-01

    Objective: To discuss the efficacy and safety of intra-arterial infusion therapy with docetaxel. Methods: Animal model of VX2 tumor in rabbit hind limb was set up. Intra-arterial infusion therapy or systemic chemotherapy with docetaxel was performed. Concentrations of docetaxel in VX2 tumor, wall of stomach, liver, kidney and plasma of rabbits with VX2 tumors in hind limbs were determined. Difference of drug concentrations between intra-arterial infusion therapy and systemic chemotherapy was compared using Student t-test. Results: Concentrations of docetaxel in VX2 tumor and wall of stomach of rabbits with intra-arterial infusion therapy were significantly higher than those with systemic chemotherapy (p<0.05). The drug concentration in VX2 tumor of rabbits with intra-arterial infusion was 14 times higher than that with systemic chemotherapy. Concentration of docetaxel in plasma of rabbits with intra-arterial infusion therapy was not significantly lower than that with systemic chemotherapy (P<0.05). Conclusion: Intra-arterial infusion therapy with docetaxel for tumor is effective. However, there is increased risk of toxicity and the dose should adjusted accordingly. (authors)

  20. Supervised segmentation of phenotype descriptions for the human skeletal phenome using hybrid methods

    Directory of Open Access Journals (Sweden)

    Groza Tudor

    2012-10-01

    Full Text Available Abstract Background Over the course of the last few years there has been a significant amount of research performed on ontology-based formalization of phenotype descriptions. In order to fully capture the intrinsic value and knowledge expressed within them, we need to take advantage of their inner structure, which implicitly combines qualities and anatomical entities. The first step in this process is the segmentation of the phenotype descriptions into their atomic elements. Results We present a two-phase hybrid segmentation method that combines a series individual classifiers using different aggregation schemes (set operations and simple majority voting. The approach is tested on a corpus comprised of skeletal phenotype descriptions emerged from the Human Phenotype Ontology. Experimental results show that the best hybrid method achieves an F-Score of 97.05% in the first phase and F-Scores of 97.16% / 94.50% in the second phase. Conclusions The performance of the initial segmentation of anatomical entities and qualities (phase I is not affected by the presence / absence of external resources, such as domain dictionaries. From a generic perspective, hybrid methods may not always improve the segmentation accuracy as they are heavily dependent on the goal and data characteristics.

  1. Septal co-infusions of glucose with the benzodiazepine agonist chlordiazepoxide impair memory, but co-infusions of glucose with the opiate morphine do not.

    Science.gov (United States)

    Krebs-Kraft, Desiree L; Parent, Marise B

    2010-03-30

    We have found repeatedly that medial septal (MS) infusions of glucose impair memory when co-infused with the gamma-amino butyric acid (GABA) agonist muscimol. The present experiments sought to determine whether the memory-impairing effects of this concentration of glucose would generalize to another GABA(A) receptor agonist and to an agonist from another neurotransmitter system that is known to impair memory. Specifically, we determined whether the dose of glucose that produces memory deficits when combined with muscimol in the MS would also impair memory when co-infused with the GABA(A) receptor modulator chlordiazepoxide (CDP) or the opiate morphine. Male Sprague-Dawley rats were given MS co-infusions and then 15 min later tested for spontaneous alternation or given shock avoidance training (retention tested 48 h later). The results showed that MS infusions of the higher dose of glucose with morphine did not produce memory deficits, whereas, the performance of rats given MS co-infusions of CDP with glucose was impaired. These findings suggest that the memory-impairing effects of brain glucose administration may involve an interaction with the GABA(A) receptor. (c) 2009 Elsevier Inc. All rights reserved.

  2. Revised Evaluation of Hemodilution Response in the Semi-Closed Loop Infusion System

    OpenAIRE

    Markevicius, Vytautas; Cincikas, Darius; Porvaneckas, Narunas; Stankevicius, Edgaras; Navikas, Dangirutis; Andriukaitis, Darius; Sipylaite, Jurate; Svediene, Saule; Uvarovas, Valentinas; Satkauskas, Igoris; Kvederas, Giedrius; Valinevicius, Algimantas; Zilys, Mindaugas; Andrijauskas, Audrius

    2017-01-01

    A mini volume loading test (mVLT) method is used for decision making in our prototype semi-closed loop infusion system (SCLIS). The mVLT fluid protocol consists of hemodilution response-guided mini fluid challenges. Each mini fluid challenge (MFC) consists of a 2.5 ml kg-1–5 ml kg-1 crystalloid bolus infused over 2 min–5 min and followed by a 5 min period with no fluids. Arterial plasma dilution efficacy (aPDE) of a MFC is calculated from invasively measured hemoglobin (aHb) before and after ...

  3. 75 FR 21641 - Infusion Pumps; Public Meeting; Request for Comments

    Science.gov (United States)

    2010-04-26

    ...] Infusion Pumps; Public Meeting; Request for Comments AGENCY: Food and Drug Administration, HHS. ACTION... announcing a public meeting regarding external infusion pumps. The purpose of the meeting is to inform the public about current problems associated with external infusion pump use, to help the agency identify...

  4. Antioxidant Properties of Pecan Nut [Carya illinoinensis (Wangenh.) C. Koch] Shell Infusion

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro do Prado, A. C.; Monalise Aragao, A.; Fett, R.; Block, J. M.

    2009-07-01

    The nutritional composition of Pecan nut [Ca rya illinoinensis (Wangenh.) C. Koch] shells and the total phenolic and condensed tannin contents of Pecan nut shell infusion were determined and the antioxidant activity of the infusion was evaluated through ABTS, DPPH and {beta}-carotene/linoleic acid systems. The shell presented high fiber content (48% {+-} 0.06), the total phenolic content ranged from 116 to 167 mg GAE/g and the condensed tannin content was between 35 and 48 mg CE/g. The antioxidant activity varied from 1112 and 1763 {mu}mol TEAC/g in the ABTS system. In the DPPH method, the antioxidant activity was from 305 to 488 mg TEAC/g (30 minutes reaction) and from 482 to 683 mg TEAC/g (24 h reaction). The oxidation inhibition percentage obtained in the {beta}-carotene/linoleic acid system varied from 70 to 96%. The results indicated the high phenolic content and antioxidant activity of Pecan nut shell infusion. (Author) 28 refs.

  5. Thermo-optic characteristics of hybrid polymer/silica microstructured optical fiber: An analytical approach

    Science.gov (United States)

    Sharma, Dinesh Kumar; Sharma, Anurag; Tripathi, Saurabh Mani

    2018-04-01

    Microstructured optical fibers (MOFs) allow a variety of advanced materials to be infiltrated in their air-voids for obtaining the increased fiber functionality, and offering a new versatile platform for developing the compact sensors devices. We aim to investigate the thermal characteristics of high-index core triangular hybrid polymer/silica MOFs with circular air-voids infused with polymer by using the analytical field model [1]. We demonstrate that infiltration of air-voids with polymer, e.g., polydimethylsiloxane (PDMS) can facilitate to tune the fundamental modal properties of MOF such as effective index of the mode, near and the far-field profiles, effective mode area and the numerical aperture over the temperature ranging from 0 °C to 100 °C, for different values of relative air-void ratios. The evolution of the mode shape for a given temperature has been investigated in transition from near-field to far-field regime. We have studied the thermal dependence of splice losses between hybrid MOF and the standard step-index single-mode optical fiber in combination with Fresnel losses. For enhancing the evanescent field interactions, we have evaluated fraction of power associated with fundamental mode of hybrid MOF. We have compared the accuracy of our results with those based on full-vector finite-difference (FD) method, as available in the literature.

  6. SVC Planning in Large–scale Power Systems via a Hybrid Optimization Method

    DEFF Research Database (Denmark)

    Yang, Guang ya; Majumder, Rajat; Xu, Zhao

    2009-01-01

    The research on allocation of FACTS devices has attracted quite a lot interests from various aspects. In this paper, a hybrid model is proposed to optimise the number, location as well as the parameter settings of static Var compensator (SVC) deployed in large–scale power systems. The model...... utilises the result of vulnerability assessment for determining the candidate locations. A hybrid optimisation method including two stages is proposed to find out the optimal solution of SVC in large– scale planning problem. In the first stage, a conventional genetic algorithm (GA) is exploited to generate...... a candidate solution pool. Then in the second stage, the candidates are presented to a linear planning model to investigate the system optimal loadability, hence the optimal solution for SVC planning can be achieved. The method is presented to IEEE 300–bus system....

  7. Modulation of salivation and heartburn in response to the site of acid infusion in the human oesophagus.

    Science.gov (United States)

    Dutta, S K; Agrawal, K; Mahmoud, M A

    2010-09-01

    The pathogenesis of gastro-oesophageal reflux disease includes increased acid reflux, reduced salivation and impaired peristalsis. This may depend upon the height of acid wave and magnitude of oesophageal mucosal exposure. Interestingly, the effect of site of acid infusion upon salivary secretion and heartburn has not been examined in any detail. To examine whether acid infusion in the upper oesophagus may cause increased salivation and heartburn as compared with acid infusion in the lower oesophagus. Twelve healthy male subjects (mean age 30) received infusions of HCl, citric acid and acetic acid at 10 and 20 cm above the lower oesophageal sphincter (LES) for fixed time periods. Parotid saliva collected periodically and heartburn severity scored using standardized scale. Standard statistical methods (paired t-tests, analysis of variance) were used to determine the significance of results. Acid infusion in the upper oesophagus increased parotid flow rate as compared with that in the lower oesophagus (P heartburn score at 20 cm as well as 10 cm above LES (P heartburn in response to acid infusion in the upper vs. lower part of the oesophagus. 2010 Blackwell Publishing Ltd.

  8. Digital Model-Based Engineering: Expectations, Prerequisites, and Challenges of Infusion

    Science.gov (United States)

    Hale, J. P.; Zimmerman, P.; Kukkala, G.; Guerrero, J.; Kobryn, P.; Puchek, B.; Bisconti, M.; Baldwin, C.; Mulpuri, M.

    2017-01-01

    Digital model-based engineering (DMbE) is the use of digital artifacts, digital environments, and digital tools in the performance of engineering functions. DMbE is intended to allow an organization to progress from documentation-based engineering methods to digital methods that may provide greater flexibility, agility, and efficiency. The term 'DMbE' was developed as part of an effort by the Model-Based Systems Engineering (MBSE) Infusion Task team to identify what government organizations might expect in the course of moving to or infusing MBSE into their organizations. The Task team was established by the Interagency Working Group on Engineering Complex Systems, an informal collaboration among government systems engineering organizations. This Technical Memorandum (TM) discusses the work of the MBSE Infusion Task team to date. The Task team identified prerequisites, expectations, initial challenges, and recommendations for areas of study to pursue, as well as examples of efforts already in progress. The team identified the following five expectations associated with DMbE infusion, discussed further in this TM: (1) Informed decision making through increased transparency, and greater insight. (2) Enhanced communication. (3) Increased understanding for greater flexibility/adaptability in design. (4) Increased confidence that the capability will perform as expected. (5) Increased efficiency. The team identified the following seven challenges an organization might encounter when looking to infuse DMbE: (1) Assessing value added to the organization. Not all DMbE practices will be applicable to every situation in every organization, and not all implementations will have positive results. (2) Overcoming organizational and cultural hurdles. (3) Adopting contractual practices and technical data management. (4) Redefining configuration management. The DMbE environment changes the range of configuration information to be managed to include performance and design models

  9. Prostaglandin synthesis can be inhibited locally by infusion of NSAIDS through microdialysis catheters in human skeletal muscle

    DEFF Research Database (Denmark)

    Mikkelsen, Ulla Ramer; Helmark, Ida Carøe; Kjaer, Michael

    2008-01-01

    of nonsteroidal anti-inflammatory drugs (NSAIDs). However, to study the local role of prostaglandins, the formation of prostaglandins within the tissue must be controlled. Microdialysis enables determination of local concentrations of water-soluble substances within the tissue. In the present study......, the microdialysis method was used to infuse NSAIDs locally into human skeletal muscles producing a local block of prostaglandin formation. In addition, the graded blockade at various distances from the infusion site within the muscle during rest, exercise and recovery was determined. Microdialysis was performed...... in thigh muscles (vastus lateralis muscle) in six healthy men. One of the microdialysis catheters was used to block prostaglandin synthesis by infusion of the NSAID indomethacin. Additional catheters were placed 1 and 4 cm away from the infusion and in the contralateral leg (working control). Following 2 h...

  10. Hybrid B-Spline Collocation Method for Solving the Generalized Burgers-Fisher and Burgers-Huxley Equations

    Directory of Open Access Journals (Sweden)

    Imtiaz Wasim

    2018-01-01

    Full Text Available In this study, we introduce a new numerical technique for solving nonlinear generalized Burgers-Fisher and Burgers-Huxley equations using hybrid B-spline collocation method. This technique is based on usual finite difference scheme and Crank-Nicolson method which are used to discretize the time derivative and spatial derivatives, respectively. Furthermore, hybrid B-spline function is utilized as interpolating functions in spatial dimension. The scheme is verified unconditionally stable using the Von Neumann (Fourier method. Several test problems are considered to check the accuracy of the proposed scheme. The numerical results are in good agreement with known exact solutions and the existing schemes in literature.

  11. Associations between bolus infusion of hydrocortisone, glycemic variability and insulin infusion rate variability in critically Ill patients under moderate glycemic control

    NARCIS (Netherlands)

    van Hooijdonk, Roosmarijn T. M.; Binnekade, Jan M.; Bos, Lieuwe D. J.; Horn, Janneke; Juffermans, Nicole P.; Abu-Hanna, Ameen; Schultz, Marcus J.

    2015-01-01

    We retrospectively studied associations between bolus infusion of hydrocortisone and variability of the blood glucose level and changes in insulin rates in intensive care unit (ICU) patients. 'Glycemic variability' and 'insulin infusion rate variability' were calculated from and expressed as the

  12. Prepreg and infusion processes for modern wind turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Shennan, C. [Hexcel, Cambridge (United Kingdom)

    2013-09-01

    The different elements of wind turbine blades have been analyzed for their main function, performance requirements and drivers. Key drivers can be simplified to either performance or cost. The use of prepreg and infusion to make these blade elements has then been compared and shows, from a comparison of test laminates, that prepreg typically delivers higher mechanical performance on both glass and carbon. One of the main process differences, cure temperature, has been overcome with the introduction of M79 which cures at 70 deg. - 80 deg. C. M79 combines this low cure temperature with a much lower reaction enthalpy allowing shorter cure cycles. This means that prepregs can now be cured in the same molds, at the same temperatures and with the same foam as used in a conventional infusion process. Although prepreg and infusion are usually used separately for making blade elements, they may also be used in combination: co-infused and co-cured using prepregs for the hard to infuse unidirectional load-carrying elements and infusion for the other elements. This can thus simplify the production process. The conclusion is that unidirectional prepregs are ideally suited for the performance driven parts of the blade such as in load carrying elements. (Author)

  13. Transcriptome analysis in non-model species: a new method for the analysis of heterologous hybridization on microarrays

    Directory of Open Access Journals (Sweden)

    Jouventin Pierre

    2010-05-01

    Full Text Available Abstract Background Recent developments in high-throughput methods of analyzing transcriptomic profiles are promising for many areas of biology, including ecophysiology. However, although commercial microarrays are available for most common laboratory models, transcriptome analysis in non-traditional model species still remains a challenge. Indeed, the signal resulting from heterologous hybridization is low and difficult to interpret because of the weak complementarity between probe and target sequences, especially when no microarray dedicated to a genetically close species is available. Results We show here that transcriptome analysis in a species genetically distant from laboratory models is made possible by using MAXRS, a new method of analyzing heterologous hybridization on microarrays. This method takes advantage of the design of several commercial microarrays, with different probes targeting the same transcript. To illustrate and test this method, we analyzed the transcriptome of king penguin pectoralis muscle hybridized to Affymetrix chicken microarrays, two organisms separated by an evolutionary distance of approximately 100 million years. The differential gene expression observed between different physiological situations computed by MAXRS was confirmed by real-time PCR on 10 genes out of 11 tested. Conclusions MAXRS appears to be an appropriate method for gene expression analysis under heterologous hybridization conditions.

  14. Applications of hybrid time-frequency methods in nonlinear structural dynamics

    International Nuclear Information System (INIS)

    Politopoulos, I.; Piteau, Ph.; Borsoi, L.; Antunes, J.

    2014-01-01

    This paper presents a study on methods which may be used to compute the nonlinear response of systems whose linear properties are determined in the frequency or Laplace domain. Typically, this kind of situation may arise in soil-structure and fluid-structure interaction problems. In particular three methods are investigated: (a) the hybrid time-frequency method, (b) the computation of the convolution integral which requires an inverse Fourier or Laplace transform of the system's transfer function, and (c) the identification of an equivalent system defined in the time domain which may be solved with classical time integration methods. These methods are illustrated by their application to some simple, one degree of freedom, non-linear systems and their advantages and drawbacks are highlighted. (authors)

  15. Diffusion and dispersion characteristics of hybridized discontinuous Galerkin methods for under-resolved turbulence simulations

    Science.gov (United States)

    Moura, Rodrigo; Fernandez, Pablo; Mengaldo, Gianmarco

    2017-11-01

    We investigate the dispersion and diffusion characteristics of hybridized discontinuous Galerkin (DG) methods. This provides us with insights to develop robust and accurate high-order DG discretizations for under-resolved flow simulations. Using the eigenanalysis technique introduced in (Moura et al., JCP, 2015 and Mengaldo et al., Computers & Fluids, 2017), we present a dispersion-diffusion analysis for the linear advection-diffusion equation. The effect of the accuracy order, the Riemann flux and the viscous stabilization are investigated. Next, we examine the diffusion characteristics of hybridized DG methods for under-resolved turbulent flows. The implicit large-eddy simulation (iLES) of the inviscid and viscous Taylor-Green vortex (TGV) problems are considered to this end. The inviscid case is relevant in the limit of high Reynolds numbers Re , i.e. negligible molecular viscosity, while the viscous case explores the effect of Re on the accuracy and robustness of the simulations. The TGV cases considered here are particularly crucial to under-resolved turbulent free flows away from walls. We conclude the talk with a discussion on the connections between hybridized and standard DG methods for under-resolved flow simulations.

  16. Advancing medication infusion safety through the clinical integration of technology.

    Science.gov (United States)

    Gerhart, Donald; O'Shea, Kristen; Muller, Sharon

    2013-01-01

    Adverse drug events resulting from errors in prescribing or administering medications are preventable. Within a hospital system, numerous technologies are employed to address the common sources of medication error, including the use of electronic medical records, physician order entry, smart infusion pumps, and barcode medication administration systems. Infusion safety is inherently risky because of the high-risk medications administered and the lack of integration among the stand-alone systems in most institutions. Intravenous clinical integration (IVCI) is a technology that connects electronic medical records, physician order entry, smart infusion pumps, and barcode medication administration systems. It combines the safety features of an automatically programmed infusion pump (drug, concentration, infusion rate, and patient weight, all auto-programmed into the device) with software that provides visibility to real-time clinical infusion data. Our article describes the characteristics of IVCI at WellSpan Health and its impact on patient safety. The integrated infusion system has the capability of reducing medication errors, improving patient care, reducing in-facility costs, and supporting asset management. It can enhance continuous quality improvement efforts and efficiency of clinical work flow. After implementing IVCI, the institution realized a safer patient environment and a more streamlined work flow for pharmacy and nursing.

  17. Decentralized method for load sharing and power management in a hybrid single/three-phase islanded microgrid consisting of hybrid source PV/battery units

    DEFF Research Database (Denmark)

    Karimi, Yaser; Guerrero, Josep M.; Oraee, Hashem

    2016-01-01

    This paper proposes a new decentralized power management and load sharing method for a photovoltaic based, hybrid single/three-phase islanded microgrid consisting of various PV units, battery units and hybrid PV/battery units. The proposed method takes into account the available PV power...... and battery conditions of the units to share the load among them and power flow among different phases is performed automatically through three-phase units. Modified active power-frequency droop functions are used according to operating states of each unit and the frequency level is used as trigger...... for switching between the states. Efficacy of the proposed method in different load, PV generation and battery conditions is validated experimentally in a microgrid lab prototype consisted of one three-phase unit and two single-phase units....

  18. A Hybrid Optimization Method for Solving Bayesian Inverse Problems under Uncertainty.

    Directory of Open Access Journals (Sweden)

    Kai Zhang

    Full Text Available In this paper, we investigate the application of a new method, the Finite Difference and Stochastic Gradient (Hybrid method, for history matching in reservoir models. History matching is one of the processes of solving an inverse problem by calibrating reservoir models to dynamic behaviour of the reservoir in which an objective function is formulated based on a Bayesian approach for optimization. The goal of history matching is to identify the minimum value of an objective function that expresses the misfit between the predicted and measured data of a reservoir. To address the optimization problem, we present a novel application using a combination of the stochastic gradient and finite difference methods for solving inverse problems. The optimization is constrained by a linear equation that contains the reservoir parameters. We reformulate the reservoir model's parameters and dynamic data by operating the objective function, the approximate gradient of which can guarantee convergence. At each iteration step, we obtain the relatively 'important' elements of the gradient, which are subsequently substituted by the values from the Finite Difference method through comparing the magnitude of the components of the stochastic gradient, which forms a new gradient, and we subsequently iterate with the new gradient. Through the application of the Hybrid method, we efficiently and accurately optimize the objective function. We present a number numerical simulations in this paper that show that the method is accurate and computationally efficient.

  19. #JeSuisCharlie: Towards a Multi-Method Study of Hybrid Media Events

    Directory of Open Access Journals (Sweden)

    Johanna Sumiala

    2016-10-01

    Full Text Available This article suggests a new methodological model for the study of hybrid media events with global appeal. This model, developed in the project on the 2015 Charlie Hebdo attacks in Paris, was created specifically for researching digital media—and in particular, Twitter. The article is structured as follows. Firstly, the methodological scope is discussed against the theoretical context, e.g. the theory of media events. In the theoretical discussion, special emphasis is given to i disruptive, upsetting, or disintegrative media events and hybrid media events and ii the conditions of today’s heterogeneous and globalised media communication landscape. Secondly, the article introduces a multi-method approach developed for the analysis of hybrid media events. In this model, computational social science—namely, automated content analysis (ACA and social network analytics (SNA—are combined with a qualitative approach—specifically, digital ethnography. The article outlines three key phases for research in which the interplay between quantitative and qualitative approaches is played out. In the first phase, preliminary digital ethnography is applied to provide the outline of the event. In the second phase, quantitative social network analytics are applied to construct the digital field for research. In this phase, it is necessary to map a what is circulating on the websites and b where this circulation takes place. The third and final phase applies a qualitative approach and digital ethnography to provide a more nuanced, in-depth interpretation of what (substance/content is circulating and how this material connects with the ‘where’ in the digital landscape, hence constituting links and connections in the hybrid media landscape. In conclusion, the article reflects on how this multi-method approach contributes to understanding the workings of today’s hybrid media events: how they create and maintain symbolic battles over certain imagined

  20. Continuous intravenous morphine infusion for postoperative analgesia following posterior spinal fusion for idiopathic scoliosis.

    Science.gov (United States)

    Poe-Kochert, Connie; Tripi, Paul A; Potzman, Jennifer; Son-Hing, Jochen P; Thompson, George H

    2010-04-01

    demonstrate that a continuous postoperative morphine infusion is a safe and effective method of pain management in patients with IS following PSF and SSI.

  1. Present and future of the hybrid imaging method SPECT/CT

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2013-01-01

    Full text: Introduction: Based on the data in the literature and on our 4 year clinical experience applied for the first time in our country hybrid imaging - single photon emission tomography combined with computed tomography (SPECT / CT) it is clear that to obtain comprehensive information about the function and structure of the studied organ; the time for the diagnosis and thus the start of adequate treatment become shorter. The resulting scintigraphic image is with better quality due to CT correction of ‘diffusion’ gamma radiation, which leads to greater diagnostic accuracy. What you will learn: complex imaging method is used mainly in the field of endocrinology, cardiology, oncology, orthopedics, pulmology, neurology, and neurosurgery. It can be prove a given disease by visualization and localization of the organ lesions and determine the stage of the tumor process, to plan the type of subsequent treatment, to follow the effects of the therapy, and to predict the effect of an interventional or miniinvasive surgical procedure. Discussion: The result of the application of the hybrid imaging method is a change in the interpretation of more than half of the studied patients and in the treatment in more than a quarter of them. Conclusion: The clinical indications for SPECT/CT, and evidence of increased diagnostic accuracy compared with self- administered scintigraphic or CT methods are continuous expanded

  2. Continuous Drug Infusion for Diabetes Therapy: A Closed-Loop Control System Design

    Directory of Open Access Journals (Sweden)

    Jiming Chen

    2008-03-01

    Full Text Available While a typical way for diabetes therapy is discrete insulin infusion based on long-time interval measurement, in this paper, we design a closed-loop control system for continuous drug infusion to improve the traditional discrete methods and make diabetes therapy automatic in practice. By exploring the accumulative function of drug to insulin, a continuous injection model is proposed. Based on this model, proportional-integral-derivative (PID and fuzzy logic controllers are designed to tackle a control problem of the resulting highly nonlinear plant. Even with serious disturbance of glucose, such as nutrition absorption at meal time, the proposed scheme can perform well in simulation experiments.

  3. Mixing in the human carotid artery during carotid drug infusion studied with PET

    International Nuclear Information System (INIS)

    Junck, L.; Koeppe, R.A.; Greenberg, H.S.

    1989-01-01

    The safety and efficacy of drug infusion into the carotid artery require adequate mixing of the infused solution with carotid blood. Using positron emission tomography (PET), we studied the mixing of solutions infused into the human carotid artery in seven patients by analyzing the distribution of [15O]H2O infused into the carotid artery and by vein. At four infusion rates ranging from 0.5 to 10 ml/min, the variability in distribution averaged 16.5-17.8% among the pixels in a large volume of interest, without dependence on the infusion rate. The overall correlation between [15O]H2O influx with arterial infusion and [15O]H2O influx with venous injection was 0.78-0.82 at the four infusion rates, with no trend toward higher correlations at the faster infusion rates. The distribution into the anterior, middle, and posterior cerebral artery territories differed from distribution throughout the entire carotid territory by an average of 6.2-9.6% at the four infusion rates, with no trend toward smaller differences at the faster infusion rates. Infusions performed into a vinyl tube simulating the carotid artery indicated that at 0.5 ml/min, the velocity of fluid exiting the catheter makes no apparent contribution to mixing. We conclude that with infusions at the carotid bifurcation, mixing in the human carotid artery is complete or nearly complete over a wide range of infusion rates. The mixing appears to result from the patterns of blood flow within the artery, and not from jet effects at the catheter tip

  4. CT detection of daughter nodules in hepatocellular carcinoma after lipiodol infusion via the hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Ohishi, Hajime; Ohgami, Syoichi; Katsuragi, Masami

    1985-02-01

    The detectability of daughter nodules in 80 hepatocellular carcinomas was compared between CT assisted by Lipiodol Ultra Fluid (Lipiodol) infused via the hepatic artery and IHA (Infusion hepatic angiography). Lipiodol infused via the hepatic artery was selectively accumulated in the tumor vessels and the tumors and small daughter nodules appeared as markedly high density areas by CT. 18 cases in which the daughter nodules were detected were identified only by CT. Furthermore, in 38 cases CT demonstrated superior detectability of the daughthr nodules than IHA. In 15 cases the daughter nodules were newly detected in areas other than the invaded area where the primary tumor existed. This method is very effective in the diagnosis of daughter nodules of hepatocellular carcinoma. (author).

  5. Transarterial infusion chemotherapy with a combination of gemcitabine and 5-fluorouracil in advanced pancreatic carcinoma

    International Nuclear Information System (INIS)

    Shi Haifeng; Jin Zhengyu; Yang Ning; Liu Wei; Pan Jie; Cai Lixing; Zhao Yupei; Zhou Zhiqiang

    2002-01-01

    Objective: To retrospectively analyze the effectiveness of transarterial infusion chemotherapy of gemcitabine and 5-fluorouracil in advanced pancreatic carcinoma. Methods: Twenty-two patients with advanced pancreatic carcinoma were treated with transarterial infusion chemotherapy. Gemcitabine and 5-fluorouracil was administered to the patients via an interarterial catheter. Then the tumor response rate and clinical benefit were observed. Results: A clinical benefit was obtained in 8 patients (36.4%). The tumor response rate was 13.6%. Median survival for all the patients was 6.1 months. Median time to tumor progression was 2.9 months. Conclusion: Transarterial infusion chemotherapy with a combination of gemcitabine and 5-fluorouracil appears to have good clinical benefit and may prolong the survival time of patients with advanced pancreatic carcinoma

  6. Hybrid MCDA Methods to Integrate Multiple Ecosystem Services in Forest Management Planning: A Critical Review.

    Science.gov (United States)

    Uhde, Britta; Hahn, W Andreas; Griess, Verena C; Knoke, Thomas

    2015-08-01

    Multi-criteria decision analysis (MCDA) is a decision aid frequently used in the field of forest management planning. It includes the evaluation of multiple criteria such as the production of timber and non-timber forest products and tangible as well as intangible values of ecosystem services (ES). Hence, it is beneficial compared to those methods that take a purely financial perspective. Accordingly, MCDA methods are increasingly popular in the wide field of sustainability assessment. Hybrid approaches allow aggregating MCDA and, potentially, other decision-making techniques to make use of their individual benefits and leading to a more holistic view of the actual consequences that come with certain decisions. This review is providing a comprehensive overview of hybrid approaches that are used in forest management planning. Today, the scientific world is facing increasing challenges regarding the evaluation of ES and the trade-offs between them, for example between provisioning and regulating services. As the preferences of multiple stakeholders are essential to improve the decision process in multi-purpose forestry, participatory and hybrid approaches turn out to be of particular importance. Accordingly, hybrid methods show great potential for becoming most relevant in future decision making. Based on the review presented here, the development of models for the use in planning processes should focus on participatory modeling and the consideration of uncertainty regarding available information.

  7. Hybrid MCDA Methods to Integrate Multiple Ecosystem Services in Forest Management Planning: A Critical Review

    Science.gov (United States)

    Uhde, Britta; Andreas Hahn, W.; Griess, Verena C.; Knoke, Thomas

    2015-08-01

    Multi-criteria decision analysis (MCDA) is a decision aid frequently used in the field of forest management planning. It includes the evaluation of multiple criteria such as the production of timber and non-timber forest products and tangible as well as intangible values of ecosystem services (ES). Hence, it is beneficial compared to those methods that take a purely financial perspective. Accordingly, MCDA methods are increasingly popular in the wide field of sustainability assessment. Hybrid approaches allow aggregating MCDA and, potentially, other decision-making techniques to make use of their individual benefits and leading to a more holistic view of the actual consequences that come with certain decisions. This review is providing a comprehensive overview of hybrid approaches that are used in forest management planning. Today, the scientific world is facing increasing challenges regarding the evaluation of ES and the trade-offs between them, for example between provisioning and regulating services. As the preferences of multiple stakeholders are essential to improve the decision process in multi-purpose forestry, participatory and hybrid approaches turn out to be of particular importance. Accordingly, hybrid methods show great potential for becoming most relevant in future decision making. Based on the review presented here, the development of models for the use in planning processes should focus on participatory modeling and the consideration of uncertainty regarding available information.

  8. Mentoring and Argumentation in a Game-Infused Science Curriculum

    Science.gov (United States)

    Gould, Deena L.; Parekh, Priyanka

    2018-04-01

    Engaging in argumentation from evidence is challenging for most middle school students. We report the design of a media-based mentoring system to support middle school students in engaging in argumentation in the context of a game-infused science curriculum. Our design emphasizes learners apprenticing with college student mentors around the socio-scientific inquiry of a designed video game. We report the results of a mixed-methods study examining the use of this media-based mentoring system with students ages 11 through 14. We observed that the discourse of groups of students that engaged with the game-infused science curriculum while interacting with college student mentors via a social media platform demonstrated statistically significant higher ratings of cognitive, epistemic, and social aspects of argumentation than groups of students that engaged with the social media platform and game-infused science curriculum without mentors. We further explored the differences between the Discourses of the mentored and non-mentored groups. This analysis showed that students in the mentored groups were invited, guided, and socialized into roles of greater agency than students in the non-mentored groups. This increased agency might explain why mentored groups demonstrated higher levels of scientific argumentation than non-mentored groups. Based on our analyses, we argue that media-based mentoring may be designed around a video game to support middle school students in engaging in argumentation from evidence.

  9. Time-domain hybrid method for simulating large amplitude motions of ships advancing in waves

    Directory of Open Access Journals (Sweden)

    Shukui Liu

    2011-03-01

    Full Text Available Typical results obtained by a newly developed, nonlinear time domain hybrid method for simulating large amplitude motions of ships advancing with constant forward speed in waves are presented. The method is hybrid in the way of combining a time-domain transient Green function method and a Rankine source method. The present approach employs a simple double integration algorithm with respect to time to simulate the free-surface boundary condition. During the simulation, the diffraction and radiation forces are computed by pressure integration over the mean wetted surface, whereas the incident wave and hydrostatic restoring forces/moments are calculated on the instantaneously wetted surface of the hull. Typical numerical results of application of the method to the seakeeping performance of a standard containership, namely the ITTC S175, are herein presented. Comparisons have been made between the results from the present method, the frequency domain 3D panel method (NEWDRIFT of NTUA-SDL and available experimental data and good agreement has been observed for all studied cases between the results of the present method and comparable other data.

  10. Refractory hyperglycaemia induced by glucose-insulin-potassium infusion in acute myocardial infarction

    NARCIS (Netherlands)

    Svilaas, Tone; van der Horst, I.C.C.; Nijsten, M.W.N.; Zijlstra, F.

    2006-01-01

    Background. Recent randomised clinical trials have not confirmed the beneficial effects of glucose-insulin-potassium (GIK) infusion observed in experimental models of myocardial ischaemia and infarction. Methods. We investigated glucose levels and insulin dose in 107 patients treated with

  11. Multifunctional Hybrid Carbon Nanotube/Carbon Fiber Polymer Composites

    Science.gov (United States)

    Kang, Jin Ho; Cano, Roberto J.; Ratcliffe, James G.; Luong, Hoa; Grimsley, Brian W.; Siochi, Emilie J.

    2016-01-01

    For aircraft primary structures, carbon fiber reinforced polymer (CFRP) composites possess many advantages over conventional aluminum alloys due to their light weight, higher strengthand stiffness-to-weight ratio, and low life-cycle maintenance costs. However, the relatively low electrical and thermal conductivities of CFRP composites fail to provide structural safety in certain operational conditions such as lightning strikes. Despite several attempts to solve these issues with the addition of carbon nanotubes (CNT) into polymer matrices, and/or by interleaving CNT sheets between conventional carbon fiber (CF) composite layers, there are still interfacial problems that exist between CNTs (or CF) and the resin. In this study, hybrid CNT/CF polymer composites were fabricated by interleaving layers of CNT sheets with Hexcel® IM7/8852 prepreg. Resin concentrations from 1 wt% to 50 wt% were used to infuse the CNT sheets prior to composite fabrication. The interlaminar properties of the resulting hybrid composites were characterized by mode I and II fracture toughness testing (double cantilever beam and end-notched flexure test). Fractographical analysis was performed to study the effect of resin concentration. In addition, multi-directional physical properties like thermal conductivity of the orthotropic hybrid polymer composite were evaluated. Interleaving CNT sheets significantly improved the in-plane (axial and perpendicular direction of CF alignment) thermal conductivity of the hybrid composite laminates by 50 - 400%.

  12. The Tolerability and Efficacy of Rapid Infliximab Infusions in Patients with Inflammatory Bowel Disease.

    Science.gov (United States)

    Qazi, Taha; Shah, Bhavesh; El-Dib, Mohammed; Farraye, Francis A

    2016-02-01

    Few studies have assessed the loss of efficacy or patient and caregiver satisfaction with rapid infliximab infusions. The aim of this study is to assess the tolerability, loss of efficacy and to describe the impact on resource utilization and patient satisfaction in rapid infliximab infusions. Subjects with inflammatory bowel disease receiving rapid infliximab infusions were included in the study. Subjects received maintenance infusions from June 2011 to June 2013. Incidence of adverse reactions and the total number of rapid infliximab infusions were recorded. Efficacy was compared to published studies evaluating the long-term efficacy of infliximab infusions. Patient satisfaction was addressed through a survey following the implementation of the rapid infusion protocol. Seventy-five subjects with IBD were included in the study. Five hundred and twenty-two rapid infliximab infusions were provided to patients. There were no acute or delayed infusion reactions. Ten subjects (13 %) required either a dose escalation or interval adjustment between infliximab infusions. A majority of patients reported increased satisfaction with 1-h infliximab infusions, and 97 % of surveyed patients opted to continue rapid infusions. The rapid infliximab infusion protocol increased infusion unit efficiency by increasing capacity by 15 %. Cost savings in the elimination of nursing time translated to approximately $108,150 savings at our institution. Rapid infliximab infusions do not appear to increase the risk of loss of response compared to historical studies of long-term infliximab efficiency. A rapid infliximab infusion protocol improved efficiency in our infusion unit and increased patient and nursing satisfaction.

  13. Gradual withdrawal of remifentanil infusion may prevent opioid-induced hyperalgesia.

    Science.gov (United States)

    Comelon, M; Raeder, J; Stubhaug, A; Nielsen, C S; Draegni, T; Lenz, H

    2016-04-01

    The aim of this study was to examine if gradual withdrawal of remifentanil infusion prevented opioid-induced hyperalgesia (OIH) as opposed to abrupt withdrawal. OIH duration was also evaluated. Nineteen volunteers were enrolled in this randomized, double-blinded, placebo-controlled, crossover study. All went through three sessions: abrupt or gradual withdrawal of remifentanil infusion and placebo. Remifentanil was administered at 2.5 ng ml(-1) for 30 min before abrupt withdrawal or gradual withdrawal by 0.6 ng ml(-1) every five min. Pain was assessed at baseline, during infusion, 45-50 min and 105-110 min after end of infusions using the heat pain test (HPT) and the cold pressor test (CPT). The HPT 45 min after infusion indicated OIH development in the abrupt withdrawal session with higher pain scores compared with the gradual withdrawal and placebo sessions (both Pwithdrawal compared with placebo (P=0.93). In the CPT 50 min after end of infusion there was OIH in both remifentanil sessions compared with placebo (gradual P=0.01, abrupt Pwithdrawal of remifentanil infusion in the HPT. After abrupt withdrawal OIH was present in the HPT. In the CPT there was OIH after both gradual and abrupt withdrawal of infusion. The duration of OIH was less than 105 min for both pain modalities. NCT 01702389. EudraCT number 2011-002734-39. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Gravity Search Algorithm hybridized Recursive Least Square method for power system harmonic estimation

    Directory of Open Access Journals (Sweden)

    Santosh Kumar Singh

    2017-06-01

    Full Text Available This paper presents a new hybrid method based on Gravity Search Algorithm (GSA and Recursive Least Square (RLS, known as GSA-RLS, to solve the harmonic estimation problems in the case of time varying power signals in presence of different noises. GSA is based on the Newton’s law of gravity and mass interactions. In the proposed method, the searcher agents are a collection of masses that interact with each other using Newton’s laws of gravity and motion. The basic GSA algorithm strategy is combined with RLS algorithm sequentially in an adaptive way to update the unknown parameters (weights of the harmonic signal. Simulation and practical validation are made with the experimentation of the proposed algorithm with real time data obtained from a heavy paper industry. A comparative performance of the proposed algorithm is evaluated with other recently reported algorithms like, Differential Evolution (DE, Particle Swarm Optimization (PSO, Bacteria Foraging Optimization (BFO, Fuzzy-BFO (F-BFO hybridized with Least Square (LS and BFO hybridized with RLS algorithm, which reveals that the proposed GSA-RLS algorithm is the best in terms of accuracy, convergence and computational time.

  15. Symptomatic Tarlov Cysts: Surgical Treatment by Subcutaneous Infusion Port.

    Science.gov (United States)

    Huang, Ying; Zhu, Tong; Lin, Hongyi; Li, Jing; Zeng, Tao; Lin, Jian

    2018-05-01

    The treatment of Tarlov cysts is challenging and difficult. The objective of our study was to describe the security and efficacy of the subcutaneous infusion port for drainage of symptomatic Tarlov cysts. The authors executed a retrospective review of data from 5 symptomatic Tarlov cysts patients who were treated using a subcutaneous infusion port from June 2014 to July 2017. Numerical Rating Scale scores and the Japanese Orthopedic Association scores of back pain were analyzed. Complications and adverse effects on postoperative days 1, 7, 14, and 28 were also analyzed. The mean follow-up was 12.6 months. Five adults (3 females and 2 males) who had been symptomatic received a subcutaneous infusion port. After treatment, all patients experienced pain relief and pain alleviation lasted from 1 day to 3 years without complications and adverse effects. A subcutaneous infusion port is a useful treatment option for symptomatic Tarlov cysts. When the patients' symptoms returned and the cysts repressurized, we quickly and simply drained the cysts by using the infusion port. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Vacuum infusion manufacturing and experimental characterization of Kevlar/epoxy composites

    International Nuclear Information System (INIS)

    Ricciardi, M. R.; Giordano, M.; Antonucci, V.; Langella, A.; Nele, L.

    2014-01-01

    Epoxy/Kevlar composites have been manufactured by conventional Vacuum Infusion process and the Pulse Infusion technique. Pulse Infusion allows to control the pressure of the vacuum bag on the dry fiber reinforcement by using a proper designed pressure distributor that induces a pulsed transverse action and promotes the through thickness resin flow. The realized composite panel have been mechanically characterized by performing tensile and short beam shear tests according with the ASTM D3039 and ASTM D2344/D 2344M standard respectively in order to investigate the effect of Pulse Infusion on the tensile strength and ILSS

  17. Vacuum infusion manufacturing and experimental characterization of Kevlar/epoxy composites

    Science.gov (United States)

    Ricciardi, M. R.; Giordano, M.; Langella, A.; Nele, L.; Antonucci, V.

    2014-05-01

    Epoxy/Kevlar composites have been manufactured by conventional Vacuum Infusion process and the Pulse Infusion technique. Pulse Infusion allows to control the pressure of the vacuum bag on the dry fiber reinforcement by using a proper designed pressure distributor that induces a pulsed transverse action and promotes the through thickness resin flow. The realized composite panel have been mechanically characterized by performing tensile and short beam shear tests according with the ASTM D3039 and ASTM D2344/D 2344M standard respectively in order to investigate the effect of Pulse Infusion on the tensile strength and ILSS.

  18. The analysis and countermeasures of intravenous infusion operation assessment results analysis in nursing students at different levels

    Directory of Open Access Journals (Sweden)

    Jiao-rong ZHAO

    2013-11-01

    Full Text Available Objective:To analyze the problems existed in nursing students at different levels in the process of intravenous infusion, to make judgmental guide towards common problems in clinical teaching, to standardize nursing students’ operations at intravenous infusion, and to avoid errors and disputes. Methods: The authors analyzed the problems in secondary, tertiary, undergraduate nursing students in three levels at a provincial hospital from 2010 to 2012 during intravenous infusion therapy; and the clinical teaching administration means were also discussed. Results: the difference of the problems existed in nursing students at different levels is not significant. P values were greater than 0.05. The top five projects that lost scores are consistent. Conclusion: The key problems that can easily cause errors and disputes are those that mostly occurred in nursing students at intravenous infusion operations. In clinical teaching, judgmental guide on common problems should be emphasized, nursing students’ operations at intravenous infusion should be standardized, the critical awareness towards clinical operations should be developed, errors and disputes should be avoided, and nursing students’ sense of professionalism should be enhanced.

  19. A hybrid multiscale kinetic Monte Carlo method for simulation of copper electrodeposition

    International Nuclear Information System (INIS)

    Zheng Zheming; Stephens, Ryan M.; Braatz, Richard D.; Alkire, Richard C.; Petzold, Linda R.

    2008-01-01

    A hybrid multiscale kinetic Monte Carlo (HMKMC) method for speeding up the simulation of copper electrodeposition is presented. The fast diffusion events are simulated deterministically with a heterogeneous diffusion model which considers site-blocking effects of additives. Chemical reactions are simulated by an accelerated (tau-leaping) method for discrete stochastic simulation which adaptively selects exact discrete stochastic simulation for the appropriate reaction whenever that is necessary. The HMKMC method is seen to be accurate and highly efficient

  20. Clinical study on external carotid artery infusion (trans-femoral) treatment of recurrent nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zhou Zejian; Li Chong; Luo Pengfei; Shao Peijian; Zhang Liangming; Li Weike; Li Yong; Xu Rongde; Zhuang Wenxing; Zhang Hua

    2002-01-01

    Objective: To evaluate the effect and safety of external carotid artery infusion treatment of recurrent nasopharyngeal carcinoma (NPC). Methods: 20 cases of recurrent NPC (13 male and 7 female, age 36-65 years, mean 50 years) diagnosed by clinical examination (including nasopharyngoscope), serology (VCA-IgA) and imaging (CT, MR) and treated by external carotid artery infusion (trans-femoral) with adriamycin (or epi-adriamycin), cisplatin (or carboplatin), Pingyangmycin and 5-Fluorouracil. Results: Of all the patients, 8 cases (40%) had a complete response (CR), 7 cases (35%) had a partial response (PR). The overall response rate (CR + PR) was 75%. Cumulative survival rates at 1, 3 years were 90% (18/20), 50%(10/20) respectively. No severe side-effects and complications found. Conclusion: External carotid artery infusion (trans-femoral) should be effective and safe in the treatment of recurrent NPC

  1. Rapid infusion with rituximab: short term safety in systemic autoimmune diseases

    DEFF Research Database (Denmark)

    Larsen, Janni Lisander; Jacobsen, Soren

    2013-01-01

    To describe the incidence, types and severity of adverse events, related to an accelerated regime of rituximab infusion in patients with various autoimmune diseases. Fifty-four patients with systemic autoimmune disease, to be treated with 1,000 mg of rituximab twice 2 weeks apart, participated. Pre......-medication (oral prednisolone, anti-histamine and paracetamol) was administered 1-4 h before infusion start. The first infusion was administered over a period of 195 min. The second infusion over a period of 90 min. Any adverse events were classified using the Clinical Trials Classification of Adverse Events...... (CTCAE) v. 3.0. Ten patients (18.5%) experienced at least one infusion-related reaction (IRR) ever. The first infusion was associated with reactions in 4 CTCAE categories of which rhinitis were the most frequent. The CTCAE severity grading showed six patients (11.1%) had a grade 1 reaction. One patient...

  2. A hybrid time-domain discontinuous galerkin-boundary integral method for electromagnetic scattering analysis

    KAUST Repository

    Li, Ping; Shi, Yifei; Jiang, Lijun; Bagci, Hakan

    2014-01-01

    A scheme hybridizing discontinuous Galerkin time-domain (DGTD) and time-domain boundary integral (TDBI) methods for accurately analyzing transient electromagnetic scattering is proposed. Radiation condition is enforced using the numerical flux on the truncation boundary. The fields required by the flux are computed using the TDBI from equivalent currents introduced on a Huygens' surface enclosing the scatterer. The hybrid DGTDBI ensures that the radiation condition is mathematically exact and the resulting computation domain is as small as possible since the truncation boundary conforms to scatterer's shape and is located very close to its surface. Locally truncated domains can also be defined around each disconnected scatterer additionally reducing the size of the overall computation domain. Numerical examples demonstrating the accuracy and versatility of the proposed method are presented. © 2014 IEEE.

  3. A hybrid time-domain discontinuous galerkin-boundary integral method for electromagnetic scattering analysis

    KAUST Repository

    Li, Ping

    2014-05-01

    A scheme hybridizing discontinuous Galerkin time-domain (DGTD) and time-domain boundary integral (TDBI) methods for accurately analyzing transient electromagnetic scattering is proposed. Radiation condition is enforced using the numerical flux on the truncation boundary. The fields required by the flux are computed using the TDBI from equivalent currents introduced on a Huygens\\' surface enclosing the scatterer. The hybrid DGTDBI ensures that the radiation condition is mathematically exact and the resulting computation domain is as small as possible since the truncation boundary conforms to scatterer\\'s shape and is located very close to its surface. Locally truncated domains can also be defined around each disconnected scatterer additionally reducing the size of the overall computation domain. Numerical examples demonstrating the accuracy and versatility of the proposed method are presented. © 2014 IEEE.

  4. Rapid infusion of esketamine for unipolar and bipolar depression: a retrospective chart review

    Directory of Open Access Journals (Sweden)

    Correia-Melo FS

    2017-06-01

    Full Text Available Fernanda S Correia-Melo,1 Felipe C Argolo,1 Lucas Araújo-de-Freitas,1,2 Gustavo Carneiro Leal,1 Flávio Kapczinski,3 Acioly Luiz Lacerda,4 Lucas C Quarantini1,2 1Psychiatry Service, University Hospital, Federal University of Bahia, Salvador, Brazil; 2Postgraduate Program in Medicine and Health, Federal University of Bahia, Salvador, Brazil; 3Department of Psychiatry, Federal University of Rio Grande do Sul, Porto Alegre, Brazil; 4Department of Psychiatry, Federal University of São Paulo, São Paulo, Brazil Background: This study evaluated efficacy and safety of intravenous subanesthetic doses of esketamine using an administration time of 10 minutes in patients with treatment-resistant depression and bipolar depression.Methods: A retrospective chart review was conducted to identify patients who met the inclusion criteria for treatment-resistant depression and bipolar depression according to Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision criteria, and these patients received rapid infusion of esketamine between June 2012 and December 2015. The Montgomery–Åsberg Depression Rating Scale (MADRS was administered to measure and score depressive symptom severity before infusion and at 24 hours, 72 hours, and 7 days after infusion. In addition, Clinical Global Impression scale was administered before and 7 days after esketamine infusion.Results: Esketamine was administered to 30 patients. A total of 27 patients met the inclusion criteria and had MADRS evaluation data, which showed that 23 had unipolar and 4 had bipolar depression. Thirteen patients (48.1% showed therapeutic response (MADRS reduction ≥50% within 1 week (7 days of intervention. Remission (MADRS <7 was observed in 10 patients (37.0% in the same period. Therapeutic response and remission frequencies were seen in 16 (59.3% and 11 (40.7% patients, respectively, within 24 hours following drug infusion. The most relevant side effect observed during

  5. A method for minimum risk portfolio optimization under hybrid uncertainty

    Science.gov (United States)

    Egorova, Yu E.; Yazenin, A. V.

    2018-03-01

    In this paper, we investigate a minimum risk portfolio model under hybrid uncertainty when the profitability of financial assets is described by fuzzy random variables. According to Feng, the variance of a portfolio is defined as a crisp value. To aggregate fuzzy information the weakest (drastic) t-norm is used. We construct an equivalent stochastic problem of the minimum risk portfolio model and specify the stochastic penalty method for solving it.

  6. Dopamine plasma clearance is increased in piglets compared to neonates during continuous dopamine infusion

    DEFF Research Database (Denmark)

    Rasmussen, Martin B; Gramsbergen, Jan Bert; Eriksen, Vibeke Ramsgaard

    2018-01-01

    pharmacokinetics. METHODS: Arterial blood samples were drawn from six neonates admitted to the neonatal intensive care unit of Copenhagen University Hospital and 20 newborn piglets during continuous dopamine infusion. Furthermore, to estimate the piglet plasma dopamine half-life, blood samples were drawn at 2.......5-minute intervals after the dopamine infusion was discontinued. The plasma dopamine content was analysed by high-performance liquid chromatography with electrochemical detection. RESULTS: The dopamine displayed first-order kinetics in piglets and had a half-life of 2.5 minutes, while the median plasma...

  7. Factors Affecting Transfer of Pyrethroid Residues from Herbal Teas to Infusion and Influence of Physicochemical Properties of Pesticides

    Directory of Open Access Journals (Sweden)

    Jin-Jing Xiao

    2017-09-01

    Full Text Available The transfer of pesticide residues from herbal teas to their infusion is a subject of particular interest. In this study, a multi-residue analytical method for the determination of pyrethroids (fenpropathrin, beta-cypermethrin, lambda-cyhalothrin, and fenvalerate in honeysuckle, chrysanthemum, wolfberry, and licorice and their infusion samples was validated. The transfer of pyrethroid residues from tea to infusion was investigated at different water temperatures, tea/water ratios, and infusion intervals/times. The results show that low amounts (0–6.70% of pyrethroids were transferred under the different tea brewing conditions examined, indicating that the infusion process reduced the pyrethroid content in the extracted liquid by over 90%. Similar results were obtained for the different tea varieties, and pesticides with high water solubility and low octanol–water partition coefficients (log Kow exhibited high transfer rates. Moreover, the estimated values of the exposure risk to the pyrethroids were in the range of 0.0022–0.33, indicating that the daily intake of the four pyrethroid residues from herbal tea can be regarded as safe. The present results can support the identification of suitable tea brewing conditions for significantly reducing the pesticide residue levels in the infusion.

  8. A hybrid method of prediction of the void fraction during depressurization of diabatic systems

    International Nuclear Information System (INIS)

    Inayatullah, G.; Nicoll, W.B.; Hancox, W.T.

    1977-01-01

    The variation in vapour volumetric fraction during transient pressure, flow and power is of considerable importance in water-cooled nuclear power-reactor safety analysis. The commonly adopted procedure to predict the transient void is to solve the conservation equations using finite differences. This present method is intermediate between numerical and analytic, hence 'hybrid'. Space and time are divided into discrete intervals. Their size, however, is dictated by the imposed heat flux and pressure variations, and not by truncation error, stability or convergence, because within an interval, the solutions applied are analytic. The relatively simple hybrid method presented here can predict the void distribution in a variety of transient, diabatic, two-phase flows with simplicity, accuracy and speed. (Auth.)

  9. Dynamic response evaluation of sensorless MPPT method for hybrid PV-DFIG wind turbine system

    Directory of Open Access Journals (Sweden)

    Danvu Nguyen

    2016-01-01

    Full Text Available This research proposes a sensorless Maximum Power Point Tracking (MPPT method for a hybrid Photovoltaic-Wind system, which consists of Photovoltaic (PV system and Doubly-Fed Induction Generator (DFIG Wind Turbine. In the hybrid system, the DC/DC converter output of the PV system is directly connected to the DC-link of DFIG’s back-to-back converter. Therefore, the PV inverter and its associated circuit can be removed in this structure. Typically, the PV power is monitored by using PV current sensor and PV voltage sensor for MPPT. In this paper, the powers of converters on grid side and rotor side of DFIG are used to estimate the PV power without the PV current sensor. That can efficiently reduce the cost of the hybrid system. The detailed analysis of the sensorless MPPT method, which includes derived equations and operation response, is also presented in this paper. In addition, an overview of PV-DFIG research in literature is stated to supply comprehensive knowledge of related research.

  10. Teor de fluoretos em infusões de chá verde (Camellia sinensis Fluoride content in green tea infusions (Camellia sinensis

    Directory of Open Access Journals (Sweden)

    Márcia Reto

    2008-01-01

    Full Text Available The aim of this work was to study the influence of green tea consumption on fluoride ingestion. The extraction conditions of fluorides from green tea infusions were defined and nine brands of green tea available in Portugal were analyzed. The quantification of fluorides in the green tea was preceded by the implementation and validation of the potentiometric method (commercial fluoride selective electrode. The concentration of fluorides in the samples ranged from 0. 8 to 2. 0 mg L-1.

  11. Regional myocardial blood flow distribution during intracoronary infusion of parathyroid hormone

    International Nuclear Information System (INIS)

    Crass, M.F. III; Lust, R.M.

    1986-01-01

    Although low doses of the biologically-active fragment of parathyroid hormone PTH-(1-34), have been shown to produce potent dilation of the coronary circulation specific regional and transmural (endo/epi) myocardial blood flow (MBF) responses to the hormone have not been described. Anesthetized open-chest mongrel dogs were instrumented to quantitate coronary blood flow and other cardiodynamic parameters. PTH-(1-34) was infused into the left circumflex artery (.008 nmol kg -1 min -1 ). Using the reference withdrawal method, radionuclide-labeled microspheres were injected before (basal flow), during (8 min after new steady-state flow), and after (restoration of basal flow) a 20 min infusion of PTH-(1-34). MFB increased from 76 +- 1.9 to 152 +- 3.5 ml min -1 100 g -1 (P < .001) during PTH-(1-34) infusion. No differences in endo/epi flow ratio or regional coronary blood flow within the left ventricle were detected. Thus, in anesthetized dogs, the increase in MBF observed secondary to the PTH-(1-34)-induced decrease in coronary resistance appeared to be uniform transmurally and regionally, and is probably not the result of a shunting or steal phenomenon

  12. A hybrid method for provincial scale energy-related carbon emission allocation in China.

    Science.gov (United States)

    Bai, Hongtao; Zhang, Yingxuan; Wang, Huizhi; Huang, Yanying; Xu, He

    2014-01-01

    Achievement of carbon emission reduction targets proposed by national governments relies on provincial/state allocations. In this study, a hybrid method for provincial energy-related carbon emissions allocation in China was developed to provide a good balance between production- and consumption-based approaches. In this method, provincial energy-related carbon emissions are decomposed into direct emissions of local activities other than thermal power generation and indirect emissions as a result of electricity consumption. Based on the carbon reduction efficiency principle, the responsibility for embodied emissions of provincial product transactions is assigned entirely to the production area. The responsibility for carbon generation during the production of thermal power is borne by the electricity consumption area, which ensures that different regions with resource endowments have rational development space. Empirical studies were conducted to examine the hybrid method and three indices, per capita GDP, resource endowment index and the proportion of energy-intensive industries, were screened to preliminarily interpret the differences among China's regional carbon emissions. Uncertainty analysis and a discussion of this method are also provided herein.

  13. Is pomegranate peels infusion effective for disinfection of toothbrushes?

    Directory of Open Access Journals (Sweden)

    Priscila Lima de Luna FREIRE

    Full Text Available Abstract Introduction Methods of decontamination or sanitization of toothbrushes have been questioned. Objective This study assessed the effectiveness of pomegranate peels infusion as a disinfectant of toothbrushes against Streptococcus mutans. Material and method A sample of 16 schoolchildren aged between 7 and 9 years performed brushing 5 days/week, with a careful brushing once a day. After each day of brushing, the toothbrushes were washed and sprayed with one disinfectant solution. This procedure was repeated for 4 weeks using one of the different solutions per week: distilled water (G1; negative control, pomegranate (Punica granatum Linn peels infusion (G2, 1% sodium hypochlorite (G3 and 0.12% chlorhexidine digluconate (G4. After the fifth day, toothbrushes were collected for laboratory analysis. Toothbrushes heads were subjected to agitation in saline dilution of 10–1, 10–2,10–3, and 25 μL of each dilution were seeded in mitis salivarius agar culture medium for S. mutans colony-forming unit (CFU counting. One calibrated examiner (Kappa = 0.91 performed the CFU (mL–1 × 104 counts. Kruskal-Wallis and Dunn Multiple Comparison tests were used at a significance level of 5%. Result G1 presented the highest number of CFU (3.9 ± 8.4, followed by G2 (3.2 ± 4.0. No S. mutans growth was observed in G3 and G4. There was no statistically significant difference between G1 and G2 and between G3 and G4 (p>0.05. Conclusion Pomegranate infusion was completely ineffective for the disinfection of toothbrushes against S. mutans when compared with 1% sodium hypochlorite and 0.12% chlorhexidine digluconate solutions.

  14. Patterns in the Parathyroid Response to Sodium Bicarbonate Infusion Test in Healthy Volunteers

    Directory of Open Access Journals (Sweden)

    Theodossis S. Papavramidis

    2014-01-01

    Full Text Available Background. The sodium bicarbonate infusion test evaluates the function of the parathyroid glands. The present study aims to evaluate the range of parathyroid response in healthy individuals and the potential influence of various factors. Methods. Fifty healthy volunteers were subjected to the test. Levels of vitamin D, calcium, albumin, and PTH were measured before infusion. PTH was measured at 3, 5, 10, 30, and 60 minutes after infusion. Results. A curve describing the response of parathyroids to the test was drawn. Twenty percent of the subjects had blunted PTH response. No significant difference was observed between normal and blunted responders concerning age, BMI, baseline PTH, or calcium levels. Nonetheless, there was a significant difference in vitamin D levels (P=0.024. Interpretation. The test is easy to perform and may be used for everyday screening. It has to be clarified whether our observations are, at least partly, produced due to the presence of individuals with a constitutively blunted response or if low levels of vitamin D decrease the ability of the parathyroids to respond. Whichever the case, PTH response of normal individuals to sodium bicarbonate infusion test is more varied than previously thought and vitamin D levels influence it.

  15. Aluminum bioavailability from tea infusion.

    Science.gov (United States)

    Yokel, Robert A; Florence, Rebecca L

    2008-12-01

    The objective was to estimate oral Al bioavailability from tea infusion in the rat, using the tracer (26)Al. (26)Al citrate was injected into tea leaves. An infusion was prepared from the dried leaves and given intra-gastrically to rats which received concurrent intravenous (27)Al infusion. Oral Al bioavailability (F) was calculated from the area under the (26)Al, compared to (27)Al, serum concentration x time curves. Bioavailability from tea averaged 0.37%; not significantly different from water (F=0.3%), or basic sodium aluminum phosphate (SALP) in cheese (F=0.1-0.3%), but greater than acidic SALP in a biscuit (F=0.1%). Time to maximum serum (26)Al concentration was 1.25, 1.5, 8 and 4.8h, respectively. These results of oral Al bioavailability x daily consumption by the human suggest tea can provide a significant amount of the Al that reaches systemic circulation. This can allow distribution to its target organs of toxicity, the central nervous, skeletal and hematopoietic systems. Further testing of the hypothesis that Al contributes to Alzheimer's disease may be more warranted with studies focusing on total average daily food intake, including tea and other foods containing appreciable Al, than drinking water.

  16. Uterine arterial methotrexate infusion and embolization in the treatment of uterine adenomyosis

    International Nuclear Information System (INIS)

    Xie Jingyan; Wang Suzheng; Chen Jingfang; Xuan Yinghua; Lou Wensheng; Gu Jianping

    2008-01-01

    Objective: To study the efficacy of treating different types of uterine adenomyosis with transcatheter local infusion of methotrexate (MTX) combined with uterine arterial embolization under guidance of digital subtraction angiography (DSA). Methods: 33 cases were primarily screened out according to clinical symptoms and color Doppler and then further diagnosis as diffuse or local adenomyosis were undertaken with super selective uterine arterial angiography. The patients were then treated with uterine arterial local infusion (50 mg MTX)and embolization with PVA microsphere (diameter 450-650 μm), individually. Finally, the comparison between the preoperative and postoperative menstruation volumes, the degrees of dysmenorrheal, uterine sizes and the levels of sexual hormones of diffuse and local adenomyosis was carried out. Results: The uterine arterial local infusion of MTX combined with embolization showed no chemotherapeutic side effects. In all cases, there were decrease of menstruation amount, alleviated dysmenorrhea, reduction of uterine size, and the efficacy was more evident in diffuse adenomyosis (P<0.05). Conclusions: Micro-invasive interventional technique combined with drug therapy is promising for diffuse and local adenomyosis especially for the former. (authors)

  17. Uncertainty characterization of particle depth measurement using digital in-line holography and the hybrid method.

    Science.gov (United States)

    Gao, Jian; Guildenbecher, Daniel R; Reu, Phillip L; Chen, Jun

    2013-11-04

    In the detection of particles using digital in-line holography, measurement accuracy is substantially influenced by the hologram processing method. In particular, a number of methods have been proposed to determine the out-of-plane particle depth (z location). However, due to the lack of consistent uncertainty characterization, it has been unclear which method is best suited to a given measurement problem. In this work, depth determination accuracies of seven particle detection methods, including a recently proposed hybrid method, are systematically investigated in terms of relative depth measurement errors and uncertainties. Both synthetic and experimental holograms of particle fields are considered at conditions relevant to particle sizing and tracking. While all methods display a range of particle conditions where they are most accurate, in general the hybrid method is shown to be the most robust with depth uncertainty less than twice the particle diameter over a wide range of particle field conditions.

  18. Tolerance to continuous intrathecal baclofen infusion can be reversed by pulsatile bolus infusion

    NARCIS (Netherlands)

    Heetla, H. W.; Staal, M. J.; van Laar, T.

    Study design: Pilot study. Objective: To study the effect of pulsatile bolus infusion of intrathecal baclofen (ITB) on daily ITB dose, in patients showing dose increases, probably due to tolerance. Setting: Department of neurology and neurosurgery, University Medical Center Groningen, the

  19. Hybrid PSO-ASVR-based method for data fitting in the calibration of infrared radiometer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Sen; Li, Chengwei, E-mail: heikuanghit@163.com [School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin 150001 (China)

    2016-06-15

    The present paper describes a hybrid particle swarm optimization-adaptive support vector regression (PSO-ASVR)-based method for data fitting in the calibration of infrared radiometer. The proposed hybrid PSO-ASVR-based method is based on PSO in combination with Adaptive Processing and Support Vector Regression (SVR). The optimization technique involves setting parameters in the ASVR fitting procedure, which significantly improves the fitting accuracy. However, its use in the calibration of infrared radiometer has not yet been widely explored. Bearing this in mind, the PSO-ASVR-based method, which is based on the statistical learning theory, is successfully used here to get the relationship between the radiation of a standard source and the response of an infrared radiometer. Main advantages of this method are the flexible adjustment mechanism in data processing and the optimization mechanism in a kernel parameter setting of SVR. Numerical examples and applications to the calibration of infrared radiometer are performed to verify the performance of PSO-ASVR-based method compared to conventional data fitting methods.

  20. A Hybrid Method for the Modelling and Optimisation of Constrained Search Problems

    Directory of Open Access Journals (Sweden)

    Sitek Pawel

    2014-08-01

    Full Text Available The paper presents a concept and the outline of the implementation of a hybrid approach to modelling and solving constrained problems. Two environments of mathematical programming (in particular, integer programming and declarative programming (in particular, constraint logic programming were integrated. The strengths of integer programming and constraint logic programming, in which constraints are treated in a different way and different methods are implemented, were combined to use the strengths of both. The hybrid method is not worse than either of its components used independently. The proposed approach is particularly important for the decision models with an objective function and many discrete decision variables added up in multiple constraints. To validate the proposed approach, two illustrative examples are presented and solved. The first example is the authors’ original model of cost optimisation in the supply chain with multimodal transportation. The second one is the two-echelon variant of the well-known capacitated vehicle routing problem.

  1. Planetary Science Technology Infusion Study: Findings and Recommendations Status

    Science.gov (United States)

    Anderson, David J.; Sandifer, Carl E., II; Sarver-Verhey, Timothy R.; Vento, Daniel M.; Zakrajsek, June F.

    2014-01-01

    The Planetary Science Division (PSD) within the National Aeronautics and Space Administrations (NASA) Science Mission Directorate (SMD) at NASA Headquarters sought to understand how to better realize a scientific return on spacecraft system technology investments currently being funded. In order to achieve this objective, a team at NASA Glenn Research Center was tasked with surveying the science and mission communities to collect their insight on technology infusion and additionally sought inputs from industry, universities, and other organizations involved with proposing for future PSD missions. This survey was undertaken by issuing a Request for Information (RFI) activity that requested input from the proposing community on present technology infusion efforts. The Technology Infusion Study was initiated in March 2013 with the release of the RFI request. The evaluation team compiled and assessed this input in order to provide PSD with recommendations on how to effectively infuse new spacecraft systems technologies that it develops into future competed missions enabling increased scientific discoveries, lower mission cost, or both. This team is comprised of personnel from the Radioisotope Power Systems (RPS) Program and the In-Space Propulsion Technology (ISPT) Program staff.The RFI survey covered two aspects of technology infusion: 1) General Insight, including: their assessment of barriers to technology infusion as related to infusion approach; technology readiness; information and documentation products; communication; integration considerations; interaction with technology development areas; cost-capped mission areas; risk considerations; system level impacts and implementation; and mission pull. 2) Specific technologies from the most recent PSD Announcements of Opportunities (AOs): The Advanced Stirling Radioisotope Generator (ASRG), aerocapture and aeroshell hardware technologies, the NASA Evolutionary Xenon Thruster (NEXT) ion propulsion system, and the

  2. Continuous intravenous infusions of bromodeoxyuridine as a clinical radiosensitizer

    International Nuclear Information System (INIS)

    Kinsella, T.J.; Mitchell, J.B.; Russo, A.; Aiken, M.; Morstyn, G.; Hsu, S.M.; Rowland, J.; Glatstein, E.

    1984-01-01

    Twelve patients were treated with continuous intravenous (24-hour) infusions of bromodeoxyuridine (BUdR) at 650 or 1000 mg/m2/d for up to two weeks. Myelosuppression, especially thrombocytopenia, was the major systemic toxicity and limited the infusion period to nine to 14 days. However, bone marrow recovery occurred within seven to ten days, allowing for a second infusion in most patients. Local toxicity (within the radiation field) was minimal, with the exception of one of four patients, who underwent abdominal irradiation. Pharmacology studies revealed a steady-state arterial plasma level of 6 x 10(-7) mol/L and 1 x 10(-6) mol/L during infusion of 650 and 1000 mg/m2/d, respectively. In vivo BUdR uptake into normal bone marrow was evaluated in two patients by comparison of preinfusion and postinfusion in vitro radiation survival curves of marrow CFUc with enhancement ratios (D0-pre/D0-post) of 1.8 (with 650 mg/m2/d) and 2.5 (with 1000 mg/m2/d). In vivo BUdR incorporation into normal skin and tumor cells using an anti-BUdR monoclonal antibody and immunohistochemistry was demonstrated in biopsies from three patients revealing substantially less cellular incorporation into normal skin (less than 10%) compared with tumor (up to 50% to 70%). The authors conclude that local and systemic toxicity of continuous infusion of BUdR at 1000 mg/m2/d for approximately two weeks is tolerable. The observed normal tissue toxicity is comparable with previous clinical experience with intermittent (12 hours every day for two weeks) infusions of BUdR. Theoretically, a constant infusion should allow for greater incorporation of BUdR into cycling tumor cells and thus, for further enhancement of radiosensitization

  3. A comparison of generalized hybrid Monte Carlo methods with and without momentum flip

    International Nuclear Information System (INIS)

    Akhmatskaya, Elena; Bou-Rabee, Nawaf; Reich, Sebastian

    2009-01-01

    The generalized hybrid Monte Carlo (GHMC) method combines Metropolis corrected constant energy simulations with a partial random refreshment step in the particle momenta. The standard detailed balance condition requires that momenta are negated upon rejection of a molecular dynamics proposal step. The implication is a trajectory reversal upon rejection, which is undesirable when interpreting GHMC as thermostated molecular dynamics. We show that a modified detailed balance condition can be used to implement GHMC without momentum flips. The same modification can be applied to the generalized shadow hybrid Monte Carlo (GSHMC) method. Numerical results indicate that GHMC/GSHMC implementations with momentum flip display a favorable behavior in terms of sampling efficiency, i.e., the traditional GHMC/GSHMC implementations with momentum flip got the advantage of a higher acceptance rate and faster decorrelation of Monte Carlo samples. The difference is more pronounced for GHMC. We also numerically investigate the behavior of the GHMC method as a Langevin-type thermostat. We find that the GHMC method without momentum flip interferes less with the underlying stochastic molecular dynamics in terms of autocorrelation functions and it to be preferred over the GHMC method with momentum flip. The same finding applies to GSHMC

  4. Hybrid methods to represent incomplete and uncertain information

    Energy Technology Data Exchange (ETDEWEB)

    Joslyn, C. [NASA Goddard Space Flight Center, Greenbelt, MD (United States)

    1996-12-31

    Decision making is cast in the semiotic context of perception, decision, and action loops. Towards the goal of properly grounding hybrid representations of information and uncertainty from this semiotic perspective, we consider the roles of and relations among the mathematical components of General Information Theory (GIT), particularly among fuzzy sets, possibility theory, probability theory, and random sets. We do so by using a clear distinction between the syntactic, mathematical formalism and the semantic domains of application of each of these fields, placing the emphasis on available measurement and action methods appropriate for each formalism, to which and from which the decision-making process flows.

  5. 21 CFR 880.2420 - Electronic monitor for gravity flow infusion systems.

    Science.gov (United States)

    2010-04-01

    ... and Personal Use Monitoring Devices § 880.2420 Electronic monitor for gravity flow infusion systems. (a) Identification. An electronic monitor for gravity flow infusion systems is a device used to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic monitor for gravity flow infusion...

  6. Flux-weakening control methods for hybrid excitation synchronous motor

    Directory of Open Access Journals (Sweden)

    Mingming Huang

    2015-09-01

    Full Text Available The hybrid excitation synchronous motor (HESM, which aim at combining the advantages of permanent magnet motor and wound excitation motor, have the characteristics of low-speed high-torque hill climbing and wide speed range. Firstly, a new kind of HESM is presented in the paper, and its structure and mathematical model are illustrated. Then, based on a space voltage vector control, a novel flux-weakening method for speed adjustment in the high speed region is presented. The unique feature of the proposed control method is that the HESM driving system keeps the q-axis back-EMF components invariable during the flux-weakening operation process. Moreover, a copper loss minimization algorithm is adopted to reduce the copper loss of the HESM in the high speed region. Lastly, the proposed method is validated by the simulation and the experimental results.

  7. Analysis of infusion-site reactions in renal transplant recipients receiving peripherally administered rabbit antithymocyte globulin as compared with basiliximab.

    Science.gov (United States)

    Erickson, Abbie L; Roberts, Keri; Malek, Sayeed K; Chandraker, Anil K; Tullius, Stefan G; Gabardi, Steven

    2010-06-01

    Antithymocyte globulin rabbit (r-ATG) has been used for the treatment and prevention of acute rejection in renal transplant recipients (RTR). Current manufacturer recommendations for r-ATG dictate the need for administration through a high-flow vein (central line). Previous studies have shown peripheral administration of r-ATG to be safe; however, these studies suggest the co-administration of heparin and hydrocortisone and did not compare the infusion-site reaction rates to a control group. A retrospective analysis was conducted of adult RTR receiving r-ATG or basiliximab between January 2004 and October 2006. Each agent was administered through a dedicated peripheral line. The primary endpoint was the incidence of infusion-site reactions. Other endpoints included the need to replace the intravenous catheter and the incidence of systemic thrombosis within 1 month of transplantation. During the study period, 152 peripheral infusions of r-ATG and 92 peripheral infusions of basiliximab were administered. No difference in infusion-site reactions was noted between the groups. There was also no difference either in the need for peripheral line replacement or the rates of systemic thrombosis. Peripheral administration of r-ATG is safe and can be infused without concomitant heparin and hydrocortisone. This method of r-ATG infusion was shown to be as safe as peripherally administered basiliximab.

  8. Structural hybrid reliability index and its convergent solving method based on random–fuzzy–interval reliability model

    Directory of Open Access Journals (Sweden)

    Hai An

    2016-08-01

    Full Text Available Aiming to resolve the problems of a variety of uncertainty variables that coexist in the engineering structure reliability analysis, a new hybrid reliability index to evaluate structural hybrid reliability, based on the random–fuzzy–interval model, is proposed in this article. The convergent solving method is also presented. First, the truncated probability reliability model, the fuzzy random reliability model, and the non-probabilistic interval reliability model are introduced. Then, the new hybrid reliability index definition is presented based on the random–fuzzy–interval model. Furthermore, the calculation flowchart of the hybrid reliability index is presented and it is solved using the modified limit-step length iterative algorithm, which ensures convergence. And the validity of convergent algorithm for the hybrid reliability model is verified through the calculation examples in literature. In the end, a numerical example is demonstrated to show that the hybrid reliability index is applicable for the wear reliability assessment of mechanisms, where truncated random variables, fuzzy random variables, and interval variables coexist. The demonstration also shows the good convergence of the iterative algorithm proposed in this article.

  9. Selection of hybrid vehicle for green environment using multi-attributive border approximation area comparison method

    Directory of Open Access Journals (Sweden)

    Tapas Kumar Biswas

    2018-02-01

    Full Text Available The mobility sector including all kinds of transportation systems are facing global challenges in re-spect of green environmental issues. There has been a paradigm shift in the concept of design and manufacturing of automotive vehicles keeping in mind the scarcity of fossil fuel and the impact of emission on environment due to burning of it. The addition of hybrid and electric vehicles in pas-senger car segment has got significant momentum to address the global challenges. This research investigates the performance of a group of hybrid vehicles from customers’ perspective. Among the different brands that are available in the hybrid vehicle market, smart customers have given pri-ority to vehicle cost, mileage, tail pipe emission, comfortness and high tank size volume for long drive. Considering these attributes, selection strategy for hybrid vehicles has been developed using entropy based multi-attributive border approximation area comparison (MABAC method. This research highlights the best hybrid vehicle which reduces air pollution in cities with other significant environmental benefits, reduces dependence on foreign energy imports and minimizes the annual fuel cost.

  10. Hybrid method based on embedded coupled simulation of vortex particles in grid based solution

    Science.gov (United States)

    Kornev, Nikolai

    2017-09-01

    The paper presents a novel hybrid approach developed to improve the resolution of concentrated vortices in computational fluid mechanics. The method is based on combination of a grid based and the grid free computational vortex (CVM) methods. The large scale flow structures are simulated on the grid whereas the concentrated structures are modeled using CVM. Due to this combination the advantages of both methods are strengthened whereas the disadvantages are diminished. The procedure of the separation of small concentrated vortices from the large scale ones is based on LES filtering idea. The flow dynamics is governed by two coupled transport equations taking two-way interaction between large and fine structures into account. The fine structures are mapped back to the grid if their size grows due to diffusion. Algorithmic aspects of the hybrid method are discussed. Advantages of the new approach are illustrated on some simple two dimensional canonical flows containing concentrated vortices.

  11. Systemic and regional hemodynamic effects of enalaprilat infusion in experimental normotensive sepsis

    Directory of Open Access Journals (Sweden)

    L. Rahal

    Full Text Available Angiotensin-converting enzyme inhibitors have been shown to improve splanchnic perfusion in distinct shock states. We hypothesized that enalaprilat potentiates the benefits of early fluid resuscitation in severe experimental sepsis, particularly in the splanchnic region. Anesthetized and mechanically ventilated mongrel dogs received an intravenous infusion of live Escherichia coli over a period of 30 min. Thereafter, two interventions were performed: fluid infusion (normal saline, 32 mL/kg over 30 min and enalaprilat infusion (0.02 mg kg-1 min-1 for 60 min in randomized groups. The following groups were studied: controls (fluid infusion, N = 4, E1 (enalaprilat infusion followed by fluid infusion, N = 5 and E2 (fluid infusion followed by enalaprilat infusion, N = 5. All animals were observed for a 120 min after bacterial infusion. Mean arterial pressure, cardiac output (CO, portal vein blood flow (PVBF, systemic and regional oxygen-derived variables, and lactate levels were measured. Rapid and progressive reductions in CO and PVBF were induced by the infusion of live bacteria, while minor changes were observed in mean arterial pressure. Systemic and regional territories showed a significant increase in oxygen extraction and lactate levels. Widening venous-arterial and portal-arterial pCO2 gradients were also detected. Fluid replacement promoted transient benefits in CO and PVBF. Enalaprilat after fluid resuscitation did not affect systemic or regional hemodynamic variables. We conclude that in this model of normotensive sepsis inhibition of angiotensin-converting enzyme did not interfere with the course of systemic or regional hemodynamic and oxygen-derived variables.

  12. Hybrid Geometric Calibration Method for Multi-Platform Spaceborne SAR Image with Sparse Gcps

    Science.gov (United States)

    Lv, G.; Tang, X.; Ai, B.; Li, T.; Chen, Q.

    2018-04-01

    Geometric calibration is able to provide high-accuracy geometric coordinates of spaceborne SAR image through accurate geometric parameters in the Range-Doppler model by ground control points (GCPs). However, it is very difficult to obtain GCPs that covering large-scale areas, especially in the mountainous regions. In addition, the traditional calibration method is only used for single platform SAR images and can't support the hybrid geometric calibration for multi-platform images. To solve the above problems, a hybrid geometric calibration method for multi-platform spaceborne SAR images with sparse GCPs is proposed in this paper. First, we calibrate the master image that contains GCPs. Secondly, the point tracking algorithm is used to obtain the tie points (TPs) between the master and slave images. Finally, we calibrate the slave images using TPs as the GCPs. We take the Beijing-Tianjin- Hebei region as an example to study SAR image hybrid geometric calibration method using 3 TerraSAR-X images, 3 TanDEM-X images and 5 GF-3 images covering more than 235 kilometers in the north-south direction. Geometric calibration of all images is completed using only 5 GCPs. The GPS data extracted from GNSS receiver are used to assess the plane accuracy after calibration. The results after geometric calibration with sparse GCPs show that the geometric positioning accuracy is 3 m for TSX/TDX images and 7.5 m for GF-3 images.

  13. Fluctuating functions related to quality of life in advanced Parkinson disease: effects of duodenal levodopa infusion

    DEFF Research Database (Denmark)

    Isacson, D; Bingefors, K; Sønbø Kristiansen, Ivar

    2008-01-01

    OBJECTIVE: To assess fluctuations in quality of life (QoL) and motor performance in patients with advanced Parkinson disease (PD) treated with continuous daytime duodenal levodopa/carbidopa infusion or conventional therapy. METHODS: Of 18 patients completing a 6-week trial (DIREQT), 12 were...... followed for up to 6 months and assessed using electronic diaries and the PD Questionnaire-39 (PDQ-39). RESULTS: During the trial and follow-up, major diurnal fluctuations were observed, especially for hyperkinesia, 'off' time, ability to walk and depression. Duodenal infusion was associated...... with significantly more favourable outcomes compared with conventional treatment for satisfaction with overall functioning, 'off' time and ability to walk, with improved outcomes with PDQ-39. CONCLUSIONS: Relative to conventional treatment, infusion therapy may stabilize and significantly improve motor function...

  14. Severe infusion reactions to infliximab: aetiology, immunogenicity and risk factors in patients with inflammatory bowel disease

    DEFF Research Database (Denmark)

    Steenholdt, Casper; Svenson, M; Bendtzen, K

    2011-01-01

    BACKGROUND: Infliximab (IFX) elicits acute severe infusion reactions in about 5% of patients with inflammatory bowel disease (IBD). AIM: To investigate the role of anti-IFX antibodies (Ab) and other risk factors. METHODS: The study included all IBD patients treated with IFX at a Danish university...... hospital until 2010 either continuously (IFX every 4-12 weeks) or episodically (reinitiation after >12 weeks). Anti-IFX Ab were measured using radioimmunoassay. RESULTS: Twenty-five (8%) of 315 patients experienced acute severe infusion reactions. Univariate analysis showed that patients who reacted were...... younger at the time of diagnosis (19 vs. 26 years, P=0.013) and at first IFX infusion (28 vs. 35 years, P=0.012). Furthermore, they more often received episodic therapy (72% vs. 31%, P

  15. Compass: A hybrid method for clinical and biobank data mining

    DEFF Research Database (Denmark)

    Krysiak-Baltyn, Konrad; Petersen, Thomas Nordahl; Audouze, Karine Marie Laure

    2014-01-01

    We describe a new method for identification of confident associations within large clinical data sets. The method is a hybrid of two existing methods; Self-Organizing Maps and Association Mining. We utilize Self-Organizing Maps as the initial step to reduce the search space, and then apply...... Association Mining in order to find association rules. We demonstrate that this procedure has a number of advantages compared to traditional Association Mining; it allows for handling numerical variables without a priori binning and is able to generate variable groups which act as “hotspots” for statistically...... significant associations. We showcase the method on infertility-related data from Danish military conscripts. The clinical data we analyzed contained both categorical type questionnaire data and continuous variables generated from biological measurements, including missing values. From this data set, we...

  16. PACAP-38 infusion causes sustained vasodilation of the middle meningeal artery in the rat

    DEFF Research Database (Denmark)

    Bhatt, Deepak K; Gupta, Saurabh; Olesen, Jes

    2014-01-01

    BACKGROUND: In healthy human volunteers and in migraineurs, pituitary adenylate cyclase-activating polypeptide-38 (PACAP-38) infusion caused sustained vasodilation of the middle meningeal artery (MMA) and an immediate as well as a delayed headache. All the study subjects experienced facial flushing....... Mast cells (MCs) might have a role in the long-lasting effect of PACAP-38 infusion. We hypothesized that in mast cell-depleted (MCD) rats the vascular responses to PACAP-38 would be lesser than in control rats because of a lack of vasodilatory products released during MC degranulation. METHODS: MCs...... were depleted by chronic treatment with compound 48/80. The effect of 20 minutes' intravenous (i.v.) infusion of calcitonin gene-related peptide (CGRP), PACAP-38, PACAP(6-38) (PAC-1 receptor antagonist) and PACAP-27 on the diameter of the MMA and on mean arterial blood pressure (MABP) in control...

  17. Control system and method for a hybrid electric vehicle

    Science.gov (United States)

    Tamor, Michael Alan

    2001-03-06

    Several control methods are presented for application in a hybrid electric vehicle powertrain including in various embodiments an engine, a motor/generator, a transmission coupled at an input thereof to receive torque from the engine and the motor generator coupled to augment torque provided by the engine, an energy storage device coupled to receive energy from and provide energy to the motor/generator, an engine controller (EEC) coupled to control the engine, a transmission controller (TCM) coupled to control the transmission and a vehicle system controller (VSC) adapted to control the powertrain.

  18. Numerical Study on Couette Flow in Nanostructured Channel using Molecular-continuum Hybrid Method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Youngjin; Jeong, Myunggeun; Ha, Man Yeong [Pusan Nat’l Univ., Busan (Korea, Republic of)

    2017-06-15

    A molecular-continuum hybrid method was developed to simulate microscale and nanoscale fluids where continuum fluidic cannot be used to predict Couette flow. Molecular dynamics simulation is used near the solid surface where the flow cannot be predicted by continuum fluidic, and Navier-Stokes equations are used in the other regions. Numerical simulation of Couette flow was performed using the hybrid method to investigate the effect of solid-liquid interaction and surface roughness in a nanochannel. It was found that the solid-liquid interaction and surface roughness influence the boundary condition. When the surface energy is low, slippage occurs near the solid surface, and the magnitude of slippage decreases with increase in surface energy. When the surface energy is high, a locking boundary condition is formed. The roughness disturbs slippage near the solid surface and promotes the locking boundary condition.

  19. Hybrid classifiers methods of data, knowledge, and classifier combination

    CERN Document Server

    Wozniak, Michal

    2014-01-01

    This book delivers a definite and compact knowledge on how hybridization can help improving the quality of computer classification systems. In order to make readers clearly realize the knowledge of hybridization, this book primarily focuses on introducing the different levels of hybridization and illuminating what problems we will face with as dealing with such projects. In the first instance the data and knowledge incorporated in hybridization were the action points, and then a still growing up area of classifier systems known as combined classifiers was considered. This book comprises the aforementioned state-of-the-art topics and the latest research results of the author and his team from Department of Systems and Computer Networks, Wroclaw University of Technology, including as classifier based on feature space splitting, one-class classification, imbalance data, and data stream classification.

  20. Detecting Android Malwares with High-Efficient Hybrid Analyzing Methods

    Directory of Open Access Journals (Sweden)

    Yu Liu

    2018-01-01

    Full Text Available In order to tackle the security issues caused by malwares of Android OS, we proposed a high-efficient hybrid-detecting scheme for Android malwares. Our scheme employed different analyzing methods (static and dynamic methods to construct a flexible detecting scheme. In this paper, we proposed some detecting techniques such as Com+ feature based on traditional Permission and API call features to improve the performance of static detection. The collapsing issue of traditional function call graph-based malware detection was also avoided, as we adopted feature selection and clustering method to unify function call graph features of various dimensions into same dimension. In order to verify the performance of our scheme, we built an open-access malware dataset in our experiments. The experimental results showed that the suggested scheme achieved high malware-detecting accuracy, and the scheme could be used to establish Android malware-detecting cloud services, which can automatically adopt high-efficiency analyzing methods according to the properties of the Android applications.

  1. Multistep Hybrid Extragradient Method for Triple Hierarchical Variational Inequalities

    Directory of Open Access Journals (Sweden)

    Zhao-Rong Kong

    2013-01-01

    Full Text Available We consider a triple hierarchical variational inequality problem (THVIP, that is, a variational inequality problem defined over the set of solutions of another variational inequality problem which is defined over the intersection of the fixed point set of a strict pseudocontractive mapping and the solution set of the classical variational inequality problem. Moreover, we propose a multistep hybrid extragradient method to compute the approximate solutions of the THVIP and present the convergence analysis of the sequence generated by the proposed method. We also derive a solution method for solving a system of hierarchical variational inequalities (SHVI, that is, a system of variational inequalities defined over the intersection of the fixed point set of a strict pseudocontractive mapping and the solution set of the classical variational inequality problem. Under very mild conditions, it is proven that the sequence generated by the proposed method converges strongly to a unique solution of the SHVI.

  2. Coupling Strategies Investigation of Hybrid Atomistic-Continuum Method Based on State Variable Coupling

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2017-01-01

    Full Text Available Different configurations of coupling strategies influence greatly the accuracy and convergence of the simulation results in the hybrid atomistic-continuum method. This study aims to quantitatively investigate this effect and offer the guidance on how to choose the proper configuration of coupling strategies in the hybrid atomistic-continuum method. We first propose a hybrid molecular dynamics- (MD- continuum solver in LAMMPS and OpenFOAM that exchanges state variables between the atomistic region and the continuum region and evaluate different configurations of coupling strategies using the sudden start Couette flow, aiming to find the preferable configuration that delivers better accuracy and efficiency. The major findings are as follows: (1 the C→A region plays the most important role in the overlap region and the “4-layer-1” combination achieves the best precision with a fixed width of the overlap region; (2 the data exchanging operation only needs a few sampling points closer to the occasions of interactions and decreasing the coupling exchange operations can reduce the computational load with acceptable errors; (3 the nonperiodic boundary force model with a smoothing parameter of 0.1 and a finer parameter of 20 can not only achieve the minimum disturbance near the MD-continuum interface but also keep the simulation precision.

  3. Endoplasmic Reticulum Chaperon Tauroursodeoxycholic Acid Attenuates Aldosterone-Infused Renal Injury

    Directory of Open Access Journals (Sweden)

    Honglei Guo

    2016-01-01

    Full Text Available Aldosterone (Aldo is critically involved in the development of renal injury via the production of reactive oxygen species and inflammation. Endoplasmic reticulum (ER stress is also evoked in Aldo-induced renal injury. In the present study, we investigated the role of ER stress in inflammation-mediated renal injury in Aldo-infused mice. C57BL/6J mice were randomized to receive treatment for 4 weeks as follows: vehicle infusion, Aldo infusion, vehicle infusion plus tauroursodeoxycholic acid (TUDCA, and Aldo infusion plus TUDCA. The effect of TUDCA on the Aldo-infused inflammatory response and renal injury was investigated using periodic acid-Schiff staining, real-time PCR, Western blot, and ELISA. We demonstrate that Aldo leads to impaired renal function and inhibition of ER stress via TUDCA attenuates renal fibrosis. This was indicated by decreased collagen I, collagen IV, fibronectin, and TGF-β expression, as well as the downregulation of the expression of Nlrp3 inflammasome markers, Nlrp3, ASC, IL-1β, and IL-18. This paper presents an important role for ER stress on the renal inflammatory response to Aldo. Additionally, the inhibition of ER stress by TUDCA negatively regulates the levels of these inflammatory molecules in the context of Aldo.

  4. Ubiquitous Sensor Networks: Efisiensi Sistem Kontrol Cairan Infus Pasien Rawat Inap

    Directory of Open Access Journals (Sweden)

    BUDI RAHMADYA

    2017-07-01

    Full Text Available ABSTRAKPenelitian ini membahas tentang sistem kontrol cairan infus pada pasien dengan memanfaatkan teknologi sensor networks dan mikrokontroler arduino uno.  Sensor yang digunakan adalah sensor Ultrasonik HC-SR04 yang difungsikan untuk mendeteksi sisa cairan infus. Data yang terbaca oleh sensor dikirimkan menggunakan jaringan nirkabel/wireless dari Transmitter (Tx di ruang pasien ke Receiver (Rx di ruang perawat dengan menggunakan modul wireless Xbee S2. Efisiensi dari sistem kontrol yang dibuat yaitu ketika sensor mendeteksi cairan infus mendekati batas habis cairan yang telah ditentukan maka motor yang berada pada selang infus akan berfungsi untuk menutup aliran cairan infus pada selang. Dari simulasi yang dilakukan, didapatkan hasil presentasi error ketinggian cairan infus sebesar 1.96% dan presentasi error volume cairan sebesar 2.16%. Performa dari modul wireless Xbee S2 juga di ujicoba dengan mengirimkan data dari Xbee end device ke Xbee coordinator dalam penelitian ini. Kata kunci: Infus, Sensor Networks, Sensor Ultrasonik HC-SR04, Xbee S2 dan Mikrokontroler Arduino Uno.ABSTRACTThis research discusses about intravenous fluids Control System on Patients, utilizing sensor network technology and Arduino Uno microcontroller. We used  HC-SR04 Ultrasonic sensors to detect the review time intravenous fluids. The sensors data is readable by transmitted using wireless network/wireless from Transmitter (Tx in Patients Into Space Receiver (Rx at nurse room with using XBee wireless device S2. The efficiency of the control system were made, namely when the sensor detects the approaching limits of intravenous fluids discharged liquid that has been determined then the motor that was on the infus line will serve to close the infusion fluid flow in the line. In our simulations we found, the findings obtained Presentation intravenous fluids altitude error is 1.96% and presentations volume Liquid error is 2.16%. The performance of network devices XBee S2

  5. Hybrid teaching method for undergraduate student in Marine Geology class in Indonesia

    Science.gov (United States)

    Yusuf Awaluddin, M.; Yuliadi, Lintang

    2016-04-01

    Bridging Geosciences to the future generations in interesting and interactive ways are challenging for lecturers and teachers. In the past, one-way 'classic' face-to-face teaching method has been used as the only alternative for undergraduate's Marine Geology class in Padjadjaran University, Indonesia. Currently, internet users in Indonesia have been increased significantly, among of them are young generations and students. The advantage of the internet as a teaching method in Geosciences topic in Indonesia is still limited. Here we have combined between the classic and the online method for undergraduate teaching. The case study was in Marine Geology class, Padjadjaran University, with 70 students as participants and 2 instructors. We used Edmodo platform as a primary tool in our teaching and Dropbox as cloud storage. All online teaching activities such as assignment, quiz, discussion and examination were done in concert with the classic one with proportion 60% and 40% respectively. We found that the students had the different experience in this hybrid teaching method as shown in their feedback through this platform. This hybrid method offers interactive ways not only between the lecturers and the students but also among students. Classroom meeting is still needed to expose their work and for general discussion.Nevertheless, the only problem was the lack of internet access in the campus when all our students accessing the platform at the same time.

  6. Efeitos adversos durante a infusão de infliximabe em crianças e adolescentes: estudo multicêntrico Adverse reactions during infliximab infusion in children and adolescents: multicenter study

    Directory of Open Access Journals (Sweden)

    Cássia Maria Passarelli Lupoli Barbosa

    2008-10-01

    Full Text Available OBJETIVO: Avaliar a freqüência e a gravidade dos efeitos adversos durante a infusão de infliximabe. MATERIAL E MÉTODOS: Avaliação retrospectiva de prontuários de 58 pacientes acompanhados em cinco serviços de reumatologia pediátrica. Todos apresentavam doença refratária ou eram intolerantes ao uso de uma ou mais drogas modificadoras de doença e receberam uma ou mais infusões de infliximabe. A análise estatística foi descritiva, levando-se em conta a freqüência e o tipo dos efeitos adversos, assim como sua relação com o número de infusões, a dose de infliximabe e a indicação. RESULTADOS: A média da idade na época da introdução do infliximabe foi de 12 anos e 9 meses e a média do tempo de evolução da doença foi de 7 anos e 7 meses. A principal indicação da medicação foi artrite idiopática juvenil (43. Dos 58 pacientes avaliados, 25 (43,1% apresentaram efeitos adversos durante a infusão e em 17 (29,3%, a medicação teve de ser suspensa. As reações que ocorreram foram: dispnéia (dez, náuseas e vômitos (oito, rash cutâneo (sete, choque anafilático (seis, rubor facial (cinco, angioedema (quatro, dor torácica (quatro, urticária e hipertensão, entre outras. A reação anafilática foi mais freqüente entre a quarta e a sexta infusão. CONCLUSÃO: A freqüência e a gravidade dos efeitos adversos ao infliximabe devem ser levadas em conta, não apenas por ocasião da sua indicação, mas principalmente por ocasião da escolha do local para a sua aplicação, que deve contar com estrutura para atendimento de urgência.OBJECTIVE: To evaluate the frequency and the severity of the adverse reactions during the infusion of infliximab. METHODS: We performed a retrospective chart review of 58 patients, followed up at 5 paediatric rheumatology centers. All patients presented refractory disease or were intolerant to one or more disease modifying drugs and received one or more infliximab infusions. The data analysis

  7. The satiety effects of intragastric macronutrient infusions in fatty and lean Zucker rats.

    Science.gov (United States)

    Maggio, C A; Greenwood, M R; Vasselli, J R

    1983-09-01

    To evaluate satiety in the hyperphagic, genetically obese Zucker "fatty" (fafa) rat, food-deprived fatty and lean (FaFa) control rats were given equicaloric intragastric infusions consisting largely of fat, carbohydrate, or protein. Relative to distilled water infusion, these infusions resulted in immediate reductions of food intake in both fatty and lean rats allowed to feed 20 min post-infusion. Cumulative food intakes remained reduced throughout the 2 hr period of observation. Thus, despite its hyperphagia, the fatty rat is responsive to the satiating effect of infused nutrients. However, the relative satiating effectiveness of the macronutrient infusions differed for the two genotypes. In lean rats, the different macronutrient infusions resulted in equivalent reductions of feeding. In contrast, in fatty rats, fat was the least satiating and protein was the most satiating macronutrient. Moreover, compared to lean rats, fatty rats displayed less initial suppression of feeding after fat infusion and greater overall suppression after protein infusion. These effects are consistent with the long-term feeding behavior of the fatty rat for the different macronutrients and may be related to pre- and postabsorptive metabolic alterations that have been documented in this animal.

  8. Continuous infusion of antibiotics in critically ill patients.

    Science.gov (United States)

    Smuszkiewicz, Piotr; Szałek, Edyta; Tomczak, Hanna; Grześkowiak, Edmund

    2013-02-01

    Antibiotics are the most commonly used drugs in intensive care unit patients and their supply should be based on pharmacokinetic/pharmacodynamic rules. The changes that occur in septic patients who are critically ill may be responsible for subtherapeutic antibiotic concentrations leading to poorer clinical outcomes. Evolving in time the disturbed pathophysiology in severe sepsis (high cardiac output, glomerular hyperfiltration) and therapeutic interventions (e.g. haemodynamically active drugs, mechanical ventilation, renal replacement therapy) alters antibiotic pharmacokinetics mainly through an increase in the volume of distribution and altered drug clearance. The lack of new and efficacious drugs and increased bacterial resistance are current problems of contemporary antibiotic therapy. Although intermittent administration is a standard clinical practice, alternative methods of antibiotic administration are sought, which may potentialise effects and reduce toxicity as well as contribute to inhibition of bacterial resistance. A wide range of studies prove that the application of continuous infusion of time-dependent antibiotics (beta-lactams, glycopeptides) is more rational than standard intermittent administration. However, there are also studies which do not confirm the advantage of one method over the other. In spite of controversy the continuous administration of this group of antibiotics is common practice, because the results of both studies point to the higher efficacy of this method in critically ill patients. Authors reviewed the literature to determine whether any clinical benefits exist for administration of time-dependent antibiotics by continuous infusion. Definite specification of the clinical advantage of administration this way over standard dosage requires a large-scale multi-centre randomised controlled trial.

  9. Physical and Chemical Stability of Urapidil in 0.9% Sodium Chloride in Elastomeric Infusion Pump.

    Science.gov (United States)

    Tomasello, Cristina; Leggieri, Anna; Rabbia, Franco; Veglio, Franco; Baietto, Lorena; Fulcheri, Chiara; De Nicolò, Amedeo; De Perri, Giovanni; D'Avolio, Antonio

    2016-01-01

    Urapidil is an antihypertensive agent, usually administered through intravenous bolus injection, slow-intravenous infusion, or continuous-drug infusion by perfusor. Since to date no evidences are available on drug stability in elastomeric pumps, patients have to be hospitalized. The purpose of this study was to validate an ultra-performance liquid chromatographic method to evaluate urapidil stability in an elastomeric infusion pump, in order to allow continuous infusion as home-care treatment. Analyses were conducted by diluting urapidil in an elastomeric pump. Two concentrations were evaluated: 1.6 mg/mL and 3.3 mg/mL. For the analyses, a reverse-phase ultra-performance liquid chromatographic- photodiode array detection instrument was used. Stressed degradation, pH changes, and visual clarity were used as stability indicators up to 10 days after urapidil solution preparation. The drug showed no more than 5% degradation during the test period at room temperature. No pH changes and no evidences of incompatibility were observed. Stress tests resulted in appreciable observation of degradation products. Considering the observed mean values, urapidil hydrochloride in sodium chloride 0.9% in elastomeric infusion pumps is stable for at least 10 days. These results indicate that this treatment could be administered at home for a prolonged duration (at least 7 days) with a satisfactory response. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  10. A hybrid filtering method based on a novel empirical mode decomposition for friction signals

    International Nuclear Information System (INIS)

    Li, Chengwei; Zhan, Liwei

    2015-01-01

    During a measurement, the measured signal usually contains noise. To remove the noise and preserve the important feature of the signal, we introduce a hybrid filtering method that uses a new intrinsic mode function (NIMF) and a modified Hausdorff distance. The NIMF is defined as the difference between the noisy signal and each intrinsic mode function (IMF), which is obtained by empirical mode decomposition (EMD), ensemble EMD, complementary ensemble EMD, or complete ensemble EMD with adaptive noise (CEEMDAN). The relevant mode selecting is based on the similarity between the first NIMF and the rest of the NIMFs. With this filtering method, the EMD and improved versions are used to filter the simulation and friction signals. The friction signal between an airplane tire and the runaway is recorded during a simulated airplane touchdown and features spikes of various amplitudes and noise. The filtering effectiveness of the four hybrid filtering methods are compared and discussed. The results show that the filtering method based on CEEMDAN outperforms other signal filtering methods. (paper)

  11. Clinical experience with contrast infusion sonography as an Essure confirmation test.

    Science.gov (United States)

    Connor, Viviane F

    2011-06-01

    The purpose of this study was to assess the clinical experience, including the feasibility, safety, compliance, and efficacy, of contrast infusion sonography as an Essure (Conceptus Inc, Mountain View, CA) confirmation test. A retrospective chart review and telephone survey were conducted at an academic multispecialty group. The study participants were women with Essure intervention who underwent contrast infusion sonography, transvaginal sonography, and hysterosalpingography as Essure confirmation tests. The main outcome measures included the feasibility, safety, compliance, and efficacy of contrast infusion sonography as a first-line Essure confirmation test. A total of 118 women had successful bilateral Essure placement. Of the 63 who consented to contrast infusion sonography, 53 (84.1%) had proper bilateral placement and tubal occlusion and were encouraged to rely on Essure. Four were suspected of having unilateral tubal patency; hysterosalpingography in 2 confirmed bilateral tubal occlusion, and 2 were noncompliant with second-line hysterosalpingography. Three patients suspected of having unsatisfactory or uncertain placement on initial transvaginal sonography were encouraged to undergo hysterosalpingography in lieu of contrast infusion sonography, which confirmed unsatisfactory placement in 2 and proper placement and occlusion in 1. Three contrast infusion sonographic procedures could not be completed because of technical issues; therefore, contrast infusion sonography was feasible in 95.2% of the patients (60 of 63). No notable adverse events occurred. Only 17 patients were noncompliant with any confirmation test, yielding an overall compliance rate of 86% (101 of 118). No pregnancies occurred during 669 woman-months of follow-up. The average reimbursement for contrast infusion sonography was US$251.78. Preliminary clinical data suggest that contrast infusion sonography is a feasible, safe, and accurate Essure confirmation test, which is well accepted by

  12. Thallium-201 infusion imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Kralios, A.; Wooten, W.W.

    1988-01-01

    To test the accuracy of Thallium-201 coronary artery infusion imaging of the earth during rapid changes in blood flow through a major coronary artery, the author performed a study in dogs correlating electromagnetic flow probe recordings with 201 Tl scintillation camera acquisitions. Hyperemic vascular response was produced experimentally in a major coronary artery by occlusion and release interventions which altered flow from baseline to zero during occlusion (20 seconds), followed by rapid flow increases approaching three times baseline immediately upon release of the occlusion. Flow returned to the baseline level within 60 seconds following release. Flow was also altered in a controlled fashion by other interventions. Recordings of Thallium uptake in the myocardium were displayed as a time histogram (counts per second squared vs time) which correlated very closely with electromagnetic flow probe recordings of flow (R=o.82-0.97). These experiments demonstrate a high degree of accuracy in Thallium infusion imaging to detect rapid changes in flow through a major coronary artery

  13. Detection of biomarkers for Hepatocellular Carcinoma using a hybrid univariate gene selection methods

    Directory of Open Access Journals (Sweden)

    Abdel Samee Nagwan M

    2012-08-01

    Full Text Available Abstract Background Discovering new biomarkers has a great role in improving early diagnosis of Hepatocellular carcinoma (HCC. The experimental determination of biomarkers needs a lot of time and money. This motivates this work to use in-silico prediction of biomarkers to reduce the number of experiments required for detecting new ones. This is achieved by extracting the most representative genes in microarrays of HCC. Results In this work, we provide a method for extracting the differential expressed genes, up regulated ones, that can be considered candidate biomarkers in high throughput microarrays of HCC. We examine the power of several gene selection methods (such as Pearson’s correlation coefficient, Cosine coefficient, Euclidean distance, Mutual information and Entropy with different estimators in selecting informative genes. A biological interpretation of the highly ranked genes is done using KEGG (Kyoto Encyclopedia of Genes and Genomes pathways, ENTREZ and DAVID (Database for Annotation, Visualization, and Integrated Discovery databases. The top ten genes selected using Pearson’s correlation coefficient and Cosine coefficient contained six genes that have been implicated in cancer (often multiple cancers genesis in previous studies. A fewer number of genes were obtained by the other methods (4 genes using Mutual information, 3genes using Euclidean distance and only one gene using Entropy. A better result was obtained by the utilization of a hybrid approach based on intersecting the highly ranked genes in the output of all investigated methods. This hybrid combination yielded seven genes (2 genes for HCC and 5 genes in different types of cancer in the top ten genes of the list of intersected genes. Conclusions To strengthen the effectiveness of the univariate selection methods, we propose a hybrid approach by intersecting several of these methods in a cascaded manner. This approach surpasses all of univariate selection methods when

  14. Effects of radiolabelled monoclonal antibody infusion on blood leukocytes in cancer patients

    International Nuclear Information System (INIS)

    Gridley, D.S.; Slater, J.M.; Stickney, D.R.

    1990-01-01

    This study was undertaken to investigate the effects of a single infusion of radiolabelled murine monoclonal antibody (MAb) on peripheral blood leukocytes in cancer patients. Eleven patients with disseminated colon cancer, malignant melanoma, or lung adenocarcinoma were infused with 111In-labelled anti-ZCE 025, anti-p97 type 96.5c, or LA 20207 MAb, respectively. Blood samples were obtained before infusion, immediately after infusion (1 hr), and at 4 and 7 days postinfusion. Flow cytometry analysis of CD3+, CD4+, CD8+, CD16+, and CD19+ lymphocytes showed increasing CD4:CD8 ratios in seven patients after infusion. This phenomenon was not restricted to antibody subclass or to type of cancer. Two of the remaining patients exhibited a marked post-infusion increase in CD8+ cells. In all three patients with malignant melanoma, decreasing levels of CD16+ lymphocytes were noted after infusion and natural killer cell cytotoxicity showed fluctuations which paralleled the changes in the CD16+ subpopulation. Oxygen radical production by phagocytic cells was markedly affected in three subjects. These results suggest that a single infusion of radiolabelled murine MAb may alter the balance of critical lymphocyte subpopulations and modulate other leukocyte responses in cancer patients

  15. Amino acid infusion during anesthesia attenuates the surgery induced decline in IGF-1 and diminishes the "diabetes of injury"

    Directory of Open Access Journals (Sweden)

    Eksborg Staffan

    2007-01-01

    Full Text Available Abstract Background Surgery, commonly performed after an overnight fast, causes a postoperative decline in the anabolic and glucose lowering insulin-like growth factor-1 (IGF-1. Clinical fasting studies have exhibited a positive correlation between IGF-1 and nitrogen balance during different conditions. A perioperative amino acid infusion changes nitrogen balance and might thereby influence serum IGF-1. We hypothesized that amino acid infusion would enhance IGF-1 and thereby might influence glucose homeostasis after surgery. In this study we examined two different regimes of perioperative amino acids infusion. Methods 24 females scheduled for abdominal hysterectomy were randomized into three groups; Ringer's solution infusion throughout anesthesia (Group B, amino acid infusion throughout anesthesia (Group C and amino acid infusion 1 hour before anesthesia and during 1.5 hrs of surgery (Group D. Six female volunteers, who were not operated, but received the same amino acids infusion after fasting, served as controls (Group A. Fasting levels of IGF-1, Insulin-like growth factor binding protein-1 (IGFBP-1, insulin and P-glucose were studied prior to, and four days following, operation. Homeostasis model assessment (HOMA was used as an index of insulin resistance. Non-parametric statistical methods were used. Results During the study the Ringer-group exhibited a decrease in IGF-1 and an increase in insulin and plasma glucose after surgery. Within the other groups there were no significant alterations over time after surgery, with the exception of a postoperative decrease in IGF-1 in group D. Group C had higher IGF-1 levels compared to group B on all days. Also, group D had higher IGF-1 levels than group B on day 2 – 4. From baseline to the first postoperative day there was a significant increase in HOMA and IGFBP-1 in groups B and C. These changes were not found in group D, in which insulin, glucose, HOMA and IGFBP-1 did not change. Amino acid

  16. Infusion pumps and red blood cell damage in transfusion therapy: an integrative revision of the academic literature

    Directory of Open Access Journals (Sweden)

    Ana Maria Miranda Martins Wilson

    Full Text Available ABSTRACT Objectives: to obtain information from scientific literature concerning infusion pumps used in administering erythrocyte (red blood cells and to evaluate the implications in the practical use of this equipment by nurses when conducting transfusions. Method: an integrative revision of the following scientific databases: Pubmed/Medline, Scopus, the Virtual Library for Health, SciELO, Web of Science and Cochrane. The following descriptors were used: "infusion pumps", "blood transfusion", "transfused erythrocyte" and "hemolyis". There were no restrictions on the scope of the initial data and it was finalized in December 2014. 17 articles were identified in accordance with the inclusion and exclusion criteria. Results: all of the publications included in the studies were experimental in vitro and covered the use of infusion pumps in transfusion therapy. A summary of the data was presented in a synoptic chart and an analysis of it generated the following categories: cellular damage and the infusion mechanism. Conclusion: infusion pumps can be harmful to erythrocytes based on the infusion mechanism that is used, as the linear peristaltic pump is more likely to cause hemolysis. Cellular damage is related to the plasmatic liberation of markers that largely dominate free hemoglobin and potassium. We reiterate the need for further research and technological investments to guide the development of protocols that promote safe practices and that can contribute to future clinical studies.

  17. Hybrid and Parallel Domain-Decomposition Methods Development to Enable Monte Carlo for Reactor Analyses

    International Nuclear Information System (INIS)

    Wagner, John C.; Mosher, Scott W.; Evans, Thomas M.; Peplow, Douglas E.; Turner, John A.

    2010-01-01

    This paper describes code and methods development at the Oak Ridge National Laboratory focused on enabling high-fidelity, large-scale reactor analyses with Monte Carlo (MC). Current state-of-the-art tools and methods used to perform real commercial reactor analyses have several undesirable features, the most significant of which is the non-rigorous spatial decomposition scheme. Monte Carlo methods, which allow detailed and accurate modeling of the full geometry and are considered the gold standard for radiation transport solutions, are playing an ever-increasing role in correcting and/or verifying the deterministic, multi-level spatial decomposition methodology in current practice. However, the prohibitive computational requirements associated with obtaining fully converged, system-wide solutions restrict the role of MC to benchmarking deterministic results at a limited number of state-points for a limited number of relevant quantities. The goal of this research is to change this paradigm by enabling direct use of MC for full-core reactor analyses. The most significant of the many technical challenges that must be overcome are the slow, non-uniform convergence of system-wide MC estimates and the memory requirements associated with detailed solutions throughout a reactor (problems involving hundreds of millions of different material and tally regions due to fuel irradiation, temperature distributions, and the needs associated with multi-physics code coupling). To address these challenges, our research has focused on the development and implementation of (1) a novel hybrid deterministic/MC method for determining high-precision fluxes throughout the problem space in k-eigenvalue problems and (2) an efficient MC domain-decomposition (DD) algorithm that partitions the problem phase space onto multiple processors for massively parallel systems, with statistical uncertainty estimation. The hybrid method development is based on an extension of the FW-CADIS method, which

  18. Hybrid and parallel domain-decomposition methods development to enable Monte Carlo for reactor analyses

    International Nuclear Information System (INIS)

    Wagner, J.C.; Mosher, S.W.; Evans, T.M.; Peplow, D.E.; Turner, J.A.

    2010-01-01

    This paper describes code and methods development at the Oak Ridge National Laboratory focused on enabling high-fidelity, large-scale reactor analyses with Monte Carlo (MC). Current state-of-the-art tools and methods used to perform 'real' commercial reactor analyses have several undesirable features, the most significant of which is the non-rigorous spatial decomposition scheme. Monte Carlo methods, which allow detailed and accurate modeling of the full geometry and are considered the 'gold standard' for radiation transport solutions, are playing an ever-increasing role in correcting and/or verifying the deterministic, multi-level spatial decomposition methodology in current practice. However, the prohibitive computational requirements associated with obtaining fully converged, system-wide solutions restrict the role of MC to benchmarking deterministic results at a limited number of state-points for a limited number of relevant quantities. The goal of this research is to change this paradigm by enabling direct use of MC for full-core reactor analyses. The most significant of the many technical challenges that must be overcome are the slow, non-uniform convergence of system-wide MC estimates and the memory requirements associated with detailed solutions throughout a reactor (problems involving hundreds of millions of different material and tally regions due to fuel irradiation, temperature distributions, and the needs associated with multi-physics code coupling). To address these challenges, our research has focused on the development and implementation of (1) a novel hybrid deterministic/MC method for determining high-precision fluxes throughout the problem space in k-eigenvalue problems and (2) an efficient MC domain-decomposition (DD) algorithm that partitions the problem phase space onto multiple processors for massively parallel systems, with statistical uncertainty estimation. The hybrid method development is based on an extension of the FW-CADIS method

  19. Absorption of subcutaneously infused insulin: influence of the basal rate pulse interval.

    Science.gov (United States)

    Hildebrandt, P; Birch, K; Jensen, B M; Kühl, C; Brange, J

    1985-01-01

    Eight insulin-dependent diabetic patients were given two constant infusions (each 1 IU/h) of 125I-labeled insulin into the abdominal subcutaneous tissue for about 12 h. Insulin was infused in pulses into one side of the abdomen in 6-min intervals (by means of an Auto-Syringe pump) and in the other side of the abdomen, insulin was infused in 1-h intervals (by means of a Medix pump). The size of the subcutaneous depots was continuously measured by counting the radioactivity at the infusion sites. After starting the infusions, the two depots were built up to steady-state levels at the same time and of the same size (approximately 3 IU) and with similar absorption rates. Thus, during basal rate insulin infusion, identical insulin absorption kinetics was achieved, irrespective of a 10-fold difference in the pulse rate.

  20. Diuretic Agent and Normal Saline Infusion Technique for Ultrasound-Guided Percutaneous Nephrostomies in Nondilated Pelvicaliceal Systems

    International Nuclear Information System (INIS)

    Yagci, Cemil; Ustuner, Evren; Atman, Ebru Dusunceli; Baltaci, Sumer; Uzun, Caglar; Akyar, Serdar

    2013-01-01

    Percutaneous nephrostomy (PCN) in a nondilated pelvicaliceal system is technically challenging. We describe an effective method to achieve transient dilatation of the pelvicaliceal system via induction of diuresis using infusion of a diuretic agent in normal saline, therefore allowing easier access to the pelvicaliceal system. Under real-time ultrasound guidance, the technique had been tested in 22 nephrostomies with nondilated system (a total of 20 patients with 2 patients having bilateral nephrostomies) during a 5-year period. Patients were given 40 mg of furosemide in 250 ml of normal saline solution intravenously by rapid infusion. As soon as maximum calyceal dilatation of more than 5 mm was observed, which is usually 15 min later after the end of rapid infusion, patients were positioned obliquely, and PCN procedure under ultrasound guidance was performed. The procedure was successful in 19 of the nephrostomies in 17 patients with a success rate of 86.36 % per procedure and 85 % per patient in nondilated pelvicaliceal systems. No major nephrostomy-, drug-, or technique-related complications were encountered. The technique failed to work in three patients due to the presence of double J catheters and preexisting calyceal perforation which avoided transient dilation of the pelvicaliceal system with diuresis. Diuretic infusion in saline is a feasible and effective method for PCN in nondilated pelvicaliceal systems.

  1. Diuretic Agent and Normal Saline Infusion Technique for Ultrasound-Guided Percutaneous Nephrostomies in Nondilated Pelvicaliceal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yagci, Cemil, E-mail: cemil.yagci@medicine.ankara.edu.tr; Ustuner, Evren, E-mail: evrenustuner@hotmail.com; Atman, Ebru Dusunceli, E-mail: ebrumd2001@yahoo.com [Ankara University, Department of Radiology, School of Medicine (Turkey); Baltaci, Sumer, E-mail: sbaltaci@hotmail.com [Ankara University, Department of Urology, School of Medicine (Turkey); Uzun, Caglar, E-mail: cuzun77@yahoo.com; Akyar, Serdar, E-mail: yusuf.s.akyar@medicine.ankara.edu.tr [Ankara University, Department of Radiology, School of Medicine (Turkey)

    2013-04-15

    Percutaneous nephrostomy (PCN) in a nondilated pelvicaliceal system is technically challenging. We describe an effective method to achieve transient dilatation of the pelvicaliceal system via induction of diuresis using infusion of a diuretic agent in normal saline, therefore allowing easier access to the pelvicaliceal system. Under real-time ultrasound guidance, the technique had been tested in 22 nephrostomies with nondilated system (a total of 20 patients with 2 patients having bilateral nephrostomies) during a 5-year period. Patients were given 40 mg of furosemide in 250 ml of normal saline solution intravenously by rapid infusion. As soon as maximum calyceal dilatation of more than 5 mm was observed, which is usually 15 min later after the end of rapid infusion, patients were positioned obliquely, and PCN procedure under ultrasound guidance was performed. The procedure was successful in 19 of the nephrostomies in 17 patients with a success rate of 86.36 % per procedure and 85 % per patient in nondilated pelvicaliceal systems. No major nephrostomy-, drug-, or technique-related complications were encountered. The technique failed to work in three patients due to the presence of double J catheters and preexisting calyceal perforation which avoided transient dilation of the pelvicaliceal system with diuresis. Diuretic infusion in saline is a feasible and effective method for PCN in nondilated pelvicaliceal systems.

  2. Effects of water infusions on mechanical properties of carboniferous rocks

    Energy Technology Data Exchange (ETDEWEB)

    Vavro, M; Chlebik, J

    1977-01-01

    Method of water infusion is used in the Ostrava-Karvina coal region in Czechoslovakia, where the roof of the extracted coal seam consists of thick rock layers (sandstone, Namurian B series) characterized by high resistance to compression, high coefficient of linear elasticity and high capacity of accumulating energy. When the resistance boundary is crossed and the rocks are disturbed this energy is suddenly released and transferred to the surrounding rock masses, coal seam and support system. On the basis of laboratory experiments the physico-mechanical and energy properties of carboniferous rocks together with calculation of their energy coefficient and other parameters are described and calculated. The results of research and theoretical solutions are presented. Practical use of water infusions to influence mechanical properties of sandstone in the roof of coal seams is described with the example of the Dukla coal mine. (5 refs.) (In Polish)

  3. A new infusion pathway monitoring system utilizing electrostatic induced potential.

    Science.gov (United States)

    Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Alien W; Caldwell, W Morton

    2006-01-01

    We have developed a new infusion pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer. The system is available for hospital and home use and it constantly monitors the intactness of the pathway. The sensor is an electro-conductive polymer electrode wrapped around the infusion polyvinyl chloride infusion tube. This records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltage and alerts the nursing station, via the nurse call system or PHS (personal handy phone System).

  4. Effect of Intravenous Infusion Solutions on Bioelectrical Impedance Spectroscopy.

    Science.gov (United States)

    Yap, Jason; Rafii, Mahroukh; Azcue, Maria; Pencharz, Paul

    2017-05-01

    Bioelectrical impedance (BIA) is often used to measure body fluid spaces and thereby body composition. However, in acute animal studies, we found that impedance was driven by the saline content of intravenous (IV) fluids and not by the volume. The aim of the study was to investigate the effect of 3 different fluids acutely administered on the change in impedance, specifically resistance (R). Nine healthy adults participated in 3 treatment (0.9% saline, 5% dextrose, and a mixture of 0.3% saline + 3.3% dextrose) experiments on nonconsecutive days. They all received 1 L of one of the treatments intravenously over a 1-hour period. Repeated BIA measurements were performed prior to IV infusion and then every 5 minutes for the 1-hour infusion period, plus 3 more measurements up to 15 minutes after the completion of the infusion. The change in R in the 0.9% saline infusion experiment was significantly lower than that of the glucose and mixture treatment ( P < .001). Bioelectrical impedance spectroscopy and BIA measure salt rather than the volume changes over the infusion period. Hence, in patients receiving IV fluids, BIA of any kind (single frequency or multifrequency) cannot be used to measure body fluid spaces or body composition.

  5. Hybrid Steepest-Descent Methods for Triple Hierarchical Variational Inequalities

    Directory of Open Access Journals (Sweden)

    L. C. Ceng

    2015-01-01

    Full Text Available We introduce and analyze a relaxed iterative algorithm by combining Korpelevich’s extragradient method, hybrid steepest-descent method, and Mann’s iteration method. We prove that, under appropriate assumptions, the proposed algorithm converges strongly to a common element of the fixed point set of infinitely many nonexpansive mappings, the solution set of finitely many generalized mixed equilibrium problems (GMEPs, the solution set of finitely many variational inclusions, and the solution set of general system of variational inequalities (GSVI, which is just a unique solution of a triple hierarchical variational inequality (THVI in a real Hilbert space. In addition, we also consider the application of the proposed algorithm for solving a hierarchical variational inequality problem with constraints of finitely many GMEPs, finitely many variational inclusions, and the GSVI. The results obtained in this paper improve and extend the corresponding results announced by many others.

  6. Intravenous Ketamine Infusions for Neuropathic Pain Management: A Promising Therapy in Need of Optimization.

    Science.gov (United States)

    Maher, Dermot P; Chen, Lucy; Mao, Jianren

    2017-02-01

    Intravenous ketamine infusions have been used extensively to treat often-intractable neuropathic pain conditions. Because there are many widely divergent ketamine infusion protocols described in the literature, the variation in these protocols presents a challenge for direct comparison of one protocol with another and in discerning an optimal protocol. Careful examination of the published literature suggests that ketamine infusions can be useful to treat neuropathic pain and that certain characteristics of ketamine infusions may be associated with better clinical outcomes. Increased duration of relief from neuropathic pain is associated with (1) higher total infused doses of ketamine; (2) prolonged infusion durations, although the rate of infusion does not appear to be a factor; and (3) coadministration of adjunct medications such as midazolam and/or clonidine that mitigate some of the unpleasant psychomimetic side effects. However, there are few studies designed to optimize ketamine infusion protocols by defining what an effective infusion protocol entails with regard to a respective neuropathic pain condition. Therefore, despite common clinical practice, the current state of the literature leaves the use of ketamine infusions without meaningful guidance from high-quality comparative evidence. The objectives of this topical review are to (1) analyze the available clinical evidence related to ketamine infusion protocols and (2) call for clinical studies to identify optimal ketamine infusion protocols tailored for individual neuropathic pain conditions. The Oxford Center for Evidence-Based Medicine classification for levels of evidence was used to stratify the grades of clinical recommendation for each infusion variable studied.

  7. Prospect of drug distribution to hepatic cancer in intra-arterial infusion chemotherapy. Examination by infusion of sup(81m)Kr and /sup 133/Xe via catheter into hepatic artery

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Y; Imaoka, S; Matsui, Y; Ishikawa, O; Taniguchi, K [Osaka Prefectural Center for Adult Diseases (Japan)

    1982-04-01

    Cannulation into the hepatic artery under laparotomy was performed to nine patients of non-resectable hepatic cancer (eight of hepatocellular carcinoma, and one of cholangiocellular carcinoma), and injected sup(81m)Kr (Tsub(1/2) = 13 sec.) continuously via catheter into hepatic artery as the model of continuous intra-arterial infusion chemotherapy, and /sup 133/Xe (Tsub(1/2) = 5.3 days) by bolus injection as the model of one-shot ones. During and immediately after injection, sequential scintigrams were carried out and simultaneously images were acquired on a medical computer. Higher radioactivities of both sup(81m)Kr and /sup 133/Xe were observed in tumor than non-tumor region in seven of eight patients of hepatocellular carcinoma. The radioactive ratio of tumor to non-tumor (T/C ratio) was over 1.0 in these cases. This result indicated that there was more arterial blood flow in tumor than non-tumor region, and it could be expected to obtain higher distribution of drugs in tumor on both continuous and one-shot infusion chemotherapy. The pattern of distribution of sup(81m)Kr changed according to positions of patients, and in some cases T/C ratio was higher in other positions than supine position. The most effective position of the intra-arterial infusion chemotherapy could be selected by this method. This technique seems to make it possible to prospect the arrival of drugs to the tumor and presume the effectiveness of intra-arterial infusion chemotherapy.

  8. Plasma concentrations of fentanyl with subcutaneous infusion in palliative care patients.

    Science.gov (United States)

    Miller, R S; Peterson, G M; Abbott, F; Maddocks, I; Parker, D; McLean, S

    1995-12-01

    1. Plasma concentrations of fentanyl were measured by g.c. in 20 patients (median age: 75 years and range: 54-86 years; eight females) in palliative care receiving the drug by continuous s.c. infusion (median rate: 1200 micrograms day-1 and range: 100-5000 micrograms day-1). 2. The infusion rate was significantly related to the duration of therapy (Spearman rho = 0.56, P Infusion rates and both total and unbound plasma concentrations of fentanyl were correlated (Spearman rho = 0.92, P infusion in the palliative care setting, which necessitates careful titration of dosage according to individual clinical response.

  9. Hybrid finite volume/ finite element method for radiative heat transfer in graded index media

    Science.gov (United States)

    Zhang, L.; Zhao, J. M.; Liu, L. H.; Wang, S. Y.

    2012-09-01

    The rays propagate along curved path determined by the Fermat principle in the graded index medium. The radiative transfer equation in graded index medium (GRTE) contains two specific redistribution terms (with partial derivatives to the angular coordinates) accounting for the effect of the curved ray path. In this paper, the hybrid finite volume with finite element method (hybrid FVM/FEM) (P.J. Coelho, J. Quant. Spectrosc. Radiat. Transf., vol. 93, pp. 89-101, 2005) is extended to solve the radiative heat transfer in two-dimensional absorbing-emitting-scattering graded index media, in which the spatial discretization is carried out using a FVM, while the angular discretization is by a FEM. The FEM angular discretization is demonstrated to be preferable in dealing with the redistribution terms in the GRTE. Two stiff matrix assembly schemes of the angular FEM discretization, namely, the traditional assembly approach and a new spherical assembly approach (assembly on the unit sphere of the solid angular space), are discussed. The spherical assembly scheme is demonstrated to give better results than the traditional assembly approach. The predicted heat flux distributions and temperature distributions in radiative equilibrium are determined by the proposed method and compared with the results available in other references. The proposed hybrid FVM/FEM method can predict the radiative heat transfer in absorbing-emitting-scattering graded index medium with good accuracy.

  10. Hybrid finite volume/ finite element method for radiative heat transfer in graded index media

    International Nuclear Information System (INIS)

    Zhang, L.; Zhao, J.M.; Liu, L.H.; Wang, S.Y.

    2012-01-01

    The rays propagate along curved path determined by the Fermat principle in the graded index medium. The radiative transfer equation in graded index medium (GRTE) contains two specific redistribution terms (with partial derivatives to the angular coordinates) accounting for the effect of the curved ray path. In this paper, the hybrid finite volume with finite element method (hybrid FVM/FEM) (P.J. Coelho, J. Quant. Spectrosc. Radiat. Transf., vol. 93, pp. 89-101, 2005) is extended to solve the radiative heat transfer in two-dimensional absorbing-emitting-scattering graded index media, in which the spatial discretization is carried out using a FVM, while the angular discretization is by a FEM. The FEM angular discretization is demonstrated to be preferable in dealing with the redistribution terms in the GRTE. Two stiff matrix assembly schemes of the angular FEM discretization, namely, the traditional assembly approach and a new spherical assembly approach (assembly on the unit sphere of the solid angular space), are discussed. The spherical assembly scheme is demonstrated to give better results than the traditional assembly approach. The predicted heat flux distributions and temperature distributions in radiative equilibrium are determined by the proposed method and compared with the results available in other references. The proposed hybrid FVM/FEM method can predict the radiative heat transfer in absorbing-emitting-scattering graded index medium with good accuracy.

  11. LPS infusion suppresses serum FGF21 levels in healthy adult volunteers

    DEFF Research Database (Denmark)

    Lauritzen, Esben Stistrup; Rittig, Nikolaj; Bach, Ermina

    2017-01-01

    circulating levels of FGF21 after lipopolysaccharide (LPS) infusion. DESIGN: Two randomized, single blinded, placebo-controlled crossover trials were used. SETTING: The studies were performed at a university hospital clinical research center. PATIENTS AND INTERVENTIONS: Study 1 (LPS bolus): Eight young......, healthy, lean males were investigated two times: 1) after isotonic saline injection, and 2) after LPS injection (bolus of 1 ng/kg). Each study day lasted 4 hours. Study 2 (continuous LPS infusion): Eight, healthy males were investigated two times: 1) during continuously isotonic saline infusion, and 2......) during continuously LPS infusion (0.06 ng/kg/h). Each study day lasted 4 hours. Circulating FGF21 levels were quantified every second hour by an immunoassay. RESULTS: A LPS bolus resulted in a late suppression (t = 240 minutes) of serum FGF21 (P=0.035). Continuous LPS infusion revealed no significant...

  12. Paradoxical hypotension during dobutamine infusion for myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Erguen, E.L.; Caner, B.; Atalar, E.; Karanfil, A.; Tokgoezoglu, L.

    1998-01-01

    Dobutamine as a predominant beta-1 agonist increases heart rate and myocardial contractility and at sufficient high doses, it also increases systolic blood pressure. This study was undertaken to describe instances of paradoxical hypotension during dobutamine infusion for Tl-201 myocardial perfusion SPECT study and the relationship between scintigraphic findings and hypotension occurred during dobutamine infusion. Methods: In 201 consecutive patients unable to perform adequate exercise, dobutamine Tl-201 myocardial SPECT was performed. Dobutamine was infused starting from 10 μg/kg/min increasing to 40 μ/kg/min. Paradoxical hypotension was defined as a decrease in systolic blood pressure ≥ 20 mmHg compared with baseline study. Paradoxical hypotension was observed in 40 patients (Group A) out of 201 (19.9%) while no significant change in systolic blood pressure was detected in the remaining 161 patients (Group B). Mean maximum fall in systolic blood pressure was 39±18 mmHg (range: 20-90). In 33 of 40 patients (83%) with paradoxical hypotension, scintigraphy was normal compared to 131 (81%) of the remaining 161 patients. In patients of Group A, angiography, echocardiography and tilt table tests were performed in 13, 11 and 6 patients respectively. Nine of 13 angiographic evaluations (69%), 10 of 11 echocardiographic evaluations (91%), all of the tilt table tests were normal. Additionally, all of the patients of Group A were clinically followed up at least 6 months after the myocardial perfusion scintigraphy. None of the patients had a cardiac event except one patient during the follow-up period. Conclusion: Paradoxical hypotension during dobutamine infusion for myocardial scintigraphy is not an uncommon finding and up to 19.9% patients may develop such hypotension. To maximize test safety, precautions should be taken during dobutamine myocardial stress test, since remarkable decrease in systolic blood pressure may occur. Unlike hypotension occurring with exercise

  13. Intra-arterial cis-diamminedichloroplatinum infusion treatment for widespread hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Park, Sung Il; Yang, Hee Chul; Lee, Do Yon; Shim, Yong Woon; Kim, Sang Heum; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1997-01-01

    The purpose of this study is to evaluate the therapeutic efficacy of intra-arterial infusion of Cis-diamminedichloroplatinum (C-DDP) for the treatment of hepatocellular carcinomas with widespread involvement. We retrospectively analyzed 22 patients who between July 1994 and June 1996 had undergone intra-arterial c-DDP infusion therapy for the treatment of hepatocellular carcinomas with widespread involvement. The hepatomas involved both lobes in ten, portal venous obstructions in fourteen, arterio-portal shunts in nine, and arterio-venous shunts in two. Proper hepatic artery was selected for infusion of 100 mg/BSA of C-DDP. The same procedure was repeated every 3 to 4 weeks, and the total number of infusions was 65. On the basis of WHO criteria, response was classified as complete remission, partial remission, stable, or progression of the disease. Six-month and one-year survival rates were estimated, and adverse reactions were evaluated. Although the response rate is not high, intra-arterial C-DDP infusion therapy can be used as an alternative treatment for hepatocellular carcinomas with widespread involvement; adverse reactions are tolerable. (author). 16 refs., 3 figs

  14. Vascular effects of intravenous intralipid and dextrose infusions in obese subjects.

    Science.gov (United States)

    Gosmanov, Aidar R; Smiley, Dawn D; Peng, Limin; Siquiera, Joselita; Robalino, Gonzalo; Newton, Christopher; Umpierrez, Guillermo E

    2012-10-01

    Hyperglycemia and elevated free fatty acids (FFA) are implicated in the development of endothelial dysfunction. Infusion of soy-bean oil-based lipid emulsion (Intralipid®) increases FFA levels and results in elevation of blood pressure (BP) and endothelial dysfunction in obese healthy subjects. The effects of combined hyperglycemia and high FFA on BP, endothelial function and carbohydrate metabolism are not known. Twelve obese healthy subjects received four random, 8-h IV infusions of saline, Intralipid 40 mL/h, Dextrose 10% 40 mL/h, or combined Intralipid and dextrose. Plasma levels of FFA increased by 1.03±0.34 mmol/L (p=0.009) after Intralipid, but FFAs remained unchanged during saline, dextrose, and combined Intralipid and dextrose infusion. Plasma glucose and insulin concentrations significantly increased after dextrose and combined Intralipid and dextrose (all, pdextrose infusion had neutral effects on BP and FMD. The co-administration of lipid and dextrose decreased FMD by 2.4%±2.1% (p=0.002) from baseline, but did not significantly increase systolic or diastolic BP. Short-term Intralipid infusion significantly increased FFA and BP; in contrast, FFA and BP were unchanged during combined infusion of Intralipid and dextrose. Combined Intralipid and dextrose infusion resulted in endothelial dysfunction similar to Intralipid alone. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Influence of temperature and brewing time of nettle (Urtica dioica L.) infusions on vitamin C content

    Science.gov (United States)

    Wolska, Jolanta; Czop, Michał; Jakubczyk, Karolina; Janda, Katarzyna

    Stinging nettle (Urtica dioica L.) can be found in temperate climate zones of Europe, Africa and America Nettle may be a source of nutritional ingredients, mineral salts, vitamins and antioxidants. The aim of the study was to determine the effect of temperature and brewing time Urtica dioica L. infusions from different parts of this plant on vitamin C (ascorbic acid) content. Infusions of nettle leaf, stem and root were prepared at room temperature, 50°C, 60°C, 70°C and 80°C for 10 minutes. Leaf infusions were also brewed for 5, 10, 15 and 20 minutes at initial water temperature of 60°C. The amount of vitamin C was determined by the spectrophotometric method. The best temperature of brewing nettle infusions, in terms of vitamin C concentration, is between 50 °C and 60 °C as it is sufficient to extract the substance, yet not high enough to destroy it. The optimal time of brewing appeared to be 10 minutes as the prolonged exposure to high temperature appeared to be detrimental for ascorbic acid as well.

  16. Technology Infusion Challenges from a Decision Support Perspective

    Science.gov (United States)

    Adumitroaie, V.; Weisbin, C. R.

    2009-01-01

    In a restricted science budget environment and increasingly numerous required technology developments, the technology investment decisions within NASA are objectively more and more difficult to make such that the end results are satisfying the technical objectives and all the organizational constraints. Under these conditions it is rationally desirable to build an investment portfolio, which has the highest possible technology infusion rate. Arguably the path to infusion is subject to many influencing factors, but here only the challenges associated with the very initial stages are addressed: defining the needs and the subsequent investment decision-support process. It is conceivable that decision consistency and possibly its quality suffer when the decision-making process has limited or no traceability. This paper presents a structured decision-support framework aiming to provide traceable, auditable, infusion- driven recommendations towards a selection process in which these recommendations are used as reference points in further discussions among stakeholders. In this framework addressing well-defined requirements, different measures of success can be defined based on traceability to specific selection criteria. As a direct result, even by using simplified decision models the likelihood of infusion can be probed and consequently improved.

  17. New Method of Selecting Efficient Project Portfolios in the Presence of Hybrid Uncertainty

    Directory of Open Access Journals (Sweden)

    Bogdan Rębiasz

    2016-01-01

    Full Text Available A new methods of selecting efficient project portfolios in the presence of hybrid uncertainty has been presented. Pareto optimal solutions have been defined by an algorithm for generating project portfolios. The method presented allows us to select efficient project portfolios taking into account statistical and economic dependencies between projects when some of the parameters used in the calculation of effectiveness can be expressed in the form of an interactive possibility distribution and some in the form of a probability distribution. The procedure for processing such hybrid data combines stochastic simulation with nonlinear programming. The interaction between data are modeled by correlation matrices and the interval regression. Economic dependences are taken into account by the equations balancing the production capacity of the company. The practical example presented indicates that an interaction between projects has a significant impact on the results of calculations. (original abstract

  18. Antioxidant and Astroprotective Effects of a Pulicaria incisa Infusion

    Directory of Open Access Journals (Sweden)

    Anat Elmann

    2012-01-01

    Full Text Available Oxidative stress is involved in the pathogenesis of neurodegenerative diseases such as Parkinson's and Alzheimer's diseases. Astrocytes, the most abundant glial cells in the brain, protect neurons from reactive oxygen species (ROS and provide them with trophic support, such as glial-derived neurotrophic factor (GDNF. Thus, any damage to astrocytes will affect neuronal survival. In the present study, an infusion prepared from the desert plant Pulicaria incisa (Pi was tested for its protective and antioxidant effects on astrocytes subjected to oxidative stress. The Pi infusion attenuated the intracellular accumulation of ROS following treatment with hydrogen peroxide and zinc and prevented the H2O2-induced death of astrocytes. The Pi infusion also exhibited an antioxidant effect in vitro and induced GDNF transcription in astrocytes. It is proposed that this Pi infusion be further evaluated for use as a functional beverage for the prevention and/or treatment of brain injuries and neurodegenerative diseases in which oxidative stress plays a role.

  19. Rapid-infusion rituximab in lymphoma treatment: 2-year experience in a single institution.

    Science.gov (United States)

    Atay, Sevcan; Barista, Ibrahim; Gundogdu, Fatma; Akgedik, Kiymet; Arpaci, Afey

    2012-05-01

    Rituximab is a chimeric anti-CD20 monoclonal antibody. We aimed to explore the safety and tolerability of rapid infusion rituximab, (over 90 minutes) in patients with non-Hodgkin's lymphoma at Hacettepe University Department of Medical Oncology. Adult patients diagnosed with non-Hodgkin's lymphoma who were to receive rituximab were included in the study. The schedule of administration for cycle 1 was unaltered and delivered according to the product monograph. All subsequent cycles were administered over a total infusion time of 90 minutes (20% of the dose in the first 30 minutes, then the remaining 80% over 60 minutes, total dose delivered in 500 mL). All patients were observed for infusion-related reactions during the rituximab infusion, and vital signs were recorded every 15 minutes. From July 2006 to December 2008, 75 patients with non-Hodgkin's lymphoma were treated with rituximab-based chemotherapy. A total of 372 infusions were administered. The majority of patients were treated with rituximab plus cyclophosphamide, doxorubicin, vincristine, and prednisone, or rituximab only. The 90-minute rituximab infusion schedule was well tolerated, with no grade 3 or 4 infusion-related adverse events observed. A rapid infusion rituximab over 90 minutes is well tolerated and safe when administered as the second and subsequent infusions in the course of therapy.

  20. Tracer studies with aortic infusion result in improper tracer distribution

    International Nuclear Information System (INIS)

    Wisneski, J.A.; Brooks, G.A.; Neese, R.A.; Stanley, W.C.; Morris, D.L.; Gertz, E.W.

    1986-01-01

    It has been suggested that lactate turnover can be accurately assessed by infusing radioactive lactate tracer into the aorta and sampling blood in the vena cava. However, there may be streaming of newly infused tracer in the aorta, resulting in a nonuniform arterial specific activity (SA). Furthermore vena caval blood may not be representative of mixed venous blood. The authors examined this problem in 7 anesthetized dogs with sampling catheters in the pulmonary (PA), carotid (CA), and femoral (FA) arteries, and the superior (SVC) and inferior (IVC) vena cavi. [1- 14 C]lactate was continuously infused into the left ventricle through a catheter introduced through the femoral artery. The same SA (dpm/μmol) was found in the CA and FA, indicating adequate mixing of newly infused tracer with trace. Three dogs showed differences between SVC, IVC and PA, suggesting a mixed venous sample can not be obtained from the VC. When the catheter was moved into the aorta, wide differences in SA appeared between the CA and FA, clearly reflecting streaming of tracer. These differences also appeared in the SVC and IVC. In conclusion, adequate mixing does not occur between tracer and trace in arterial blood with aortic infusion. Further, VC sampling will not give a consistent mixed venous SA. Therefore, for practical reasons, aortic tracer infusion with vena caval sampling will lead to erroneous turnover values

  1. Transfer matrix method for dynamics modeling and independent modal space vibration control design of linear hybrid multibody system

    Science.gov (United States)

    Rong, Bao; Rui, Xiaoting; Lu, Kun; Tao, Ling; Wang, Guoping; Ni, Xiaojun

    2018-05-01

    In this paper, an efficient method of dynamics modeling and vibration control design of a linear hybrid multibody system (MS) is studied based on the transfer matrix method. The natural vibration characteristics of a linear hybrid MS are solved by using low-order transfer equations. Then, by constructing the brand-new body dynamics equation, augmented operator and augmented eigenvector, the orthogonality of augmented eigenvector of a linear hybrid MS is satisfied, and its state space model expressed in each independent model space is obtained easily. According to this dynamics model, a robust independent modal space-fuzzy controller is designed for vibration control of a general MS, and the genetic optimization of some critical control parameters of fuzzy tuners is also presented. Two illustrative examples are performed, which results show that this method is computationally efficient and with perfect control performance.

  2. Scavenged body heat powered infusion pump

    International Nuclear Information System (INIS)

    Bell, Alexander; Ehringer, William D; McNamara, Shamus

    2013-01-01

    An infusion pump powered by body heat is investigated in this paper, with the goal of addressing the needs of dermal wound healing. The infusion pump incorporates a Knudsen gas pump, a type of thermally driven pump, to pneumatic push the pharmaceutical agent from a reservoir. Two designs are considered: an integrated pump and reservoir, and a design with cascaded pump and reservoir. Thermal models are developed for both pumps, and the simulations agree well with the experimental results. The integrated pump and reservoir design uses hydrophobic materials to prevent a flow from occurring unless the infusion pump is placed on a human body. Flow rates in the µL min −1 range for the integrated pump and reservoir, and approximately 70 µL min −1 for the cascaded pump were obtained. The dynamic behavior of the cascaded pump is described based on the thermal models. Multiple copies of the cascaded pump are easily made in series or parallel, to increase either the pressure or the flow rate. The flow rate of multiple pumps in series does not change, and the pressure of multiple pumps in parallel does not change. (paper)

  3. Direct numerical simulation of turbulent channel flow over a liquid-infused micro-grooved surface

    Science.gov (United States)

    Chang, Jaehee; Jung, Taeyong; Choi, Haecheon; Kim, John

    2016-11-01

    Recently a superhydrophobic surface has drawn much attention as a passive device to achieve high drag reduction. Despite the high performance promised at ideal conditions, maintaining the interface in real flow conditions is an intractable problem. A non-wetting surface, known as the slippery liquid-infused porous surface (SLIPS) or the lubricant-impregnated surface (LIS), has shown a potential for drag reduction, as the working fluid slips at the interface but cannot penetrate into the lubricant layer. In the present study, we perform direct numerical simulation of turbulent channel flow over a liquid-infused micro-grooved surface to investigate the effects of this surface on the interfacial slip and drag reduction. The flow rate of water is maintained constant corresponding to Reτ 180 in a fully developed turbulent channel flow, and the lubricant layer is shear-driven by the turbulent water flow. The lubricant layer is also simulated with the assumption that the interface is flat (i.e. the surface tension effect is neglected). The solid substrate in which the lubricant is infused is modelled as straight ridges using an immersed boundary method. DNS results show that drag reduction by the liquid-infused surface is highly dependent on the viscosity of the lubricant.

  4. A new venous infusion pathway monitoring system.

    Science.gov (United States)

    Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2007-01-01

    A new infusion catheter pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer has been developed for hospital and home use. The sensor consists of coaxial three-layer conductive tapes wrapped around the polyvinyl chloride infusion tube. The inner tape is the main electrode, which records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The outside tape layer is a reference electrode to monitor the AC voltage around the main electrode. The center tape layer is connected to system ground and functions as a shield. The microcomputer calculates the ratio of the induced AC voltages recorded by the main and reference electrodes and if the ratio indicates a detached infusion, alerts the nursing station, via the nurse call system or low transmitting power mobile phone.

  5. Design of time interval generator based on hybrid counting method

    International Nuclear Information System (INIS)

    Yao, Yuan; Wang, Zhaoqi; Lu, Houbing; Chen, Lian; Jin, Ge

    2016-01-01

    Time Interval Generators (TIGs) are frequently used for the characterizations or timing operations of instruments in particle physics experiments. Though some “off-the-shelf” TIGs can be employed, the necessity of a custom test system or control system makes the TIGs, being implemented in a programmable device desirable. Nowadays, the feasibility of using Field Programmable Gate Arrays (FPGAs) to implement particle physics instrumentation has been validated in the design of Time-to-Digital Converters (TDCs) for precise time measurement. The FPGA-TDC technique is based on the architectures of Tapped Delay Line (TDL), whose delay cells are down to few tens of picosecond. In this case, FPGA-based TIGs with high delay step are preferable allowing the implementation of customized particle physics instrumentations and other utilities on the same FPGA device. A hybrid counting method for designing TIGs with both high resolution and wide range is presented in this paper. The combination of two different counting methods realizing an integratable TIG is described in detail. A specially designed multiplexer for tap selection is emphatically introduced. The special structure of the multiplexer is devised for minimizing the different additional delays caused by the unpredictable routings from different taps to the output. A Kintex-7 FPGA is used for the hybrid counting-based implementation of a TIG, providing a resolution up to 11 ps and an interval range up to 8 s.

  6. Design of time interval generator based on hybrid counting method

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Yuan [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Wang, Zhaoqi [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Lu, Houbing [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Hefei Electronic Engineering Institute, Hefei 230037 (China); Chen, Lian [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China); Jin, Ge, E-mail: goldjin@ustc.edu.cn [State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2016-10-01

    Time Interval Generators (TIGs) are frequently used for the characterizations or timing operations of instruments in particle physics experiments. Though some “off-the-shelf” TIGs can be employed, the necessity of a custom test system or control system makes the TIGs, being implemented in a programmable device desirable. Nowadays, the feasibility of using Field Programmable Gate Arrays (FPGAs) to implement particle physics instrumentation has been validated in the design of Time-to-Digital Converters (TDCs) for precise time measurement. The FPGA-TDC technique is based on the architectures of Tapped Delay Line (TDL), whose delay cells are down to few tens of picosecond. In this case, FPGA-based TIGs with high delay step are preferable allowing the implementation of customized particle physics instrumentations and other utilities on the same FPGA device. A hybrid counting method for designing TIGs with both high resolution and wide range is presented in this paper. The combination of two different counting methods realizing an integratable TIG is described in detail. A specially designed multiplexer for tap selection is emphatically introduced. The special structure of the multiplexer is devised for minimizing the different additional delays caused by the unpredictable routings from different taps to the output. A Kintex-7 FPGA is used for the hybrid counting-based implementation of a TIG, providing a resolution up to 11 ps and an interval range up to 8 s.

  7. Type of homogenization and fat loss during continuous infusion of human milk.

    Science.gov (United States)

    García-Lara, Nadia Raquel; Escuder-Vieco, Diana; Alonso Díaz, Clara; Vázquez Román, Sara; De la Cruz-Bértolo, Javier; Pallás-Alonso, Carmen Rosa

    2014-11-01

    Substantial fat loss may occur during continuous feeding of human milk (HM). A decrease of fat loss has been described following homogenization. Well-established methods of homogenization of HM for routine use in the neonatal intensive care unit (NICU) would be desirable. We compared the loss of fat based on the use of 3 different methods for homogenizing thawed HM during continuous feeding. Sixteen frozen donor HM samples were thawed, homogenized with ultrasound and separated into 3 aliquots ("baseline agitation," "hourly agitation," and "ultrasound"), and then frozen for 48 hours. Aliquots were thawed again and a baseline agitation was applied. Subsequently, aliquots baseline agitation and hourly agitation were drawn into a syringe, while ultrasound was applied to aliquot ultrasound before it was drawn into a syringe. The syringes were loaded into a pump (2 mL/h; 4 hours). At hourly intervals the hourly agitation infusion was stopped, the syringe was disconnected and gently shaken. During infusion, samples from the 3 groups were collected hourly for analysis of fat and caloric content. The 3 groups of homogenization showed similar fat content at the beginning of the infusion. For fat, mean (SD) hourly changes of -0.03 (0.01), -0.09 (0.01), and -0.09 (0.01) g/dL were observed for the hourly agitation, baseline agitation, and ultrasound groups, respectively. The decrease was smaller for the hourly agitation group (P homogenization is used. © The Author(s) 2014.

  8. Effect of glucose-insulin-potassium infusion on thallium myocardial clearance

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Factors influencing the rate of 201 Tl clearance from the myocardium have not been clearly defined. This study determined the effect of an intravenous infusion of glucose-insulin-potassium (GIK) on the net 201 Tl clearance rates from myocardium with and without initial 201 Tl loading. Anesthetized open-chest dogs underwent 5 min of left anterior descending coronary artery occlusion and intravenous 201 Tl was injected and the occlusion released 5 min later. Thirty minutes after 201 Tl injection, 30 ml of either GIK (nine dogs) or saline (five dogs) was infused intravenously. The clearance rates of 201 Tl from the anterior wall (without initial 201 Tl loading) and from the posterior wall (with initial 201 Tl loading) were monitored with miniaturized cadmium telluride detectors placed on the myocardium. Calculation of net myocardial clearance rates was performed by linear regression analysis from serial 1 min counts. Compared with saline infusion, GIK increased the net clearance of 201 Tl from both myocardial regions with and without initial loading. The most marked change induced by GIK infusion was in the myocardial region without initial 201 Tl loading; a net increase in 201 Tl activity (72 +/- 42 cpm/30 min) was converted into a net loss (-594 +/- 228 cpm/30 min). There was no significant change in 201 Tl clearance after the saline infusion. Heart rate, aortic and left atrial pressure, sonomicrometer-measured transmural myocardial wall thickness, microsphere-determined myocardial blood flow, and blood glucose and potassium concentrations did not change significantly during GIK or saline infusions. Thus, GIK infusion appears to increase net 201 Tl clearance from myocardial zones with and without initial 201 Tl loading

  9. Intractable Polyuria Mimicking Diabetes Insipidus-Source Traced to Vecuronium Infusion.

    Science.gov (United States)

    Haldar, Rudrashish; Samanta, Sukhen; Singla, Ankush

    2016-01-01

    Continuous infusion of vecuronium is a commonly used technique for patients requiring prolonged neuromuscular blockade for mechanical ventilation. As compared with older neuromuscular blocking agents, it confers the advantages of rapid excretion and intermediate duration of action. Prolongation of neuromuscular blockade and muscle weakness are the known complications of continuous vecuronium infusion. This report attempts to describe polyuria, as a hitherto unknown complication of vecuronium infusion, which can occur due to the mannitol present in commercially available preparation of vecuronium bromide.

  10. Anestesi Infus Gravimetrik Ketamin dan Propofol pada Anjing (THE GRAVIMETRIC INFUSION ANAESTHESIA WITH KETAMINE AND PROPOFOL IN DOGS

    Directory of Open Access Journals (Sweden)

    I Gusti Ngurah Sudisma

    2014-08-01

    Full Text Available This study aim was to evaluate quality of anaesthesia by using gravimetric infusion anaesthesia withketamine and propofol in dogs. The quality of anaesthesia, duration of actions, and the physiological responsseof anaesthesia were evaluated in twenty domestic dogs. Anaesthesia was induced intramuscularly withatropine (0.03 mg/kg-xylazine (2 mg/kg (AX, intravenously ketamine-propofol (KP (4 mg/kg, andmaintained with continuous intravenous infusion with pre-mixed propofol (P and normal saline containing2 mg/ml of propofol and 2 mg/ml of ketamine (K. Domestic stray dogs were randomly divided into fivegroups. Groups AXKP-K2P2, AXKP-K4P4, and AXKP-K6P6 were treated with ketamine-propofol the dose0.2 mg/kg/minute, 0.4 and 0.6 mg/kg/minute respectively, while group AXKP-P4 was given propofol 0.4 mg/kg/minute and group AXKP-I was given isoflurane 1-2%. Heart rate (HR, respiratory rate (RR,electrocardiogram (ECG, blood oxygen saturation (SpO2, end tidal CO2 (ET CO2, and capillary refill time(CRT were measured. No significant difference (P>0.05 found between the groups in anaesthetion times.All groups showed rapid and smooth inductions, prolonged surgical stage, and rapid recovery. Groups AXKPK2P2and AXKP-K4P4 showed minimal physiological effect on the dogs. The HR, RR, ET CO2, SpO2, CRT,and ECG wave were stabl. Combination of AXKP-K6P6 induced SpO2 depression, increased and instabilityof HR, RR and ET CO2. Groups AXKP-P4 showed decreased of HR and respiratory depression. All anaestheticcombinations showed no significant influence (P>0.05 on the electricity of the dog’s heart. The combinationof ketamine-propofol at dose 0.2 and 0.4 mg/kg/minute were found to be better as an application formaintaining anaesthesia by gravimetric continuous intravenous infusion. The method is a suitablealternative for inhalation anaesthesia in dogs.

  11. Simplified Model for the Hybrid Method to Design Stabilising Piles Placed at the Toe of Slopes

    Directory of Open Access Journals (Sweden)

    Dib M.

    2018-01-01

    Full Text Available Stabilizing precarious slopes by installing piles has become a widespread technique for landslides prevention. The design of slope-stabilizing piles by the finite element method is more accurate comparing to the conventional methods. This accuracy is because of the ability of this method to simulate complex configurations, and to analyze the soil-pile interaction effect. However, engineers prefer to use the simplified analytical techniques to design slope stabilizing piles, this is due to the high computational resources required by the finite element method. Aiming to combine the accuracy of the finite element method with simplicity of the analytical approaches, a hybrid methodology to design slope stabilizing piles was proposed in 2012. It consists of two steps; (1: an analytical estimation of the resisting force needed to stabilize the precarious slope, and (2: a numerical analysis to define the adequate pile configuration that offers the required resisting force. The hybrid method is applicable only for the analysis and the design of stabilizing piles placed in the middle of the slope, however, in certain cases like road constructions, piles are needed to be placed at the toe of the slope. Therefore, in this paper a simplified model for the hybrid method is dimensioned to analyze and design stabilizing piles placed at the toe of a precarious slope. The validation of the simplified model is presented by a comparative analysis with the full coupled finite element model.

  12. Attribute based selection of thermoplastic resin for vacuum infusion process

    DEFF Research Database (Denmark)

    Prabhakaran, R.T. Durai; Lystrup, Aage; Løgstrup Andersen, Tom

    2011-01-01

    The composite industry looks toward a new material system (resins) based on thermoplastic polymers for the vacuum infusion process, similar to the infusion process using thermosetting polymers. A large number of thermoplastics are available in the market with a variety of properties suitable...... for different engineering applications, and few of those are available in a not yet polymerised form suitable for resin infusion. The proper selection of a new resin system among these thermoplastic polymers is a concern for manufactures in the current scenario and a special mathematical tool would...... be beneficial. In this paper, the authors introduce a new decision making tool for resin selection based on significant attributes. This article provides a broad overview of suitable thermoplastic material systems for vacuum infusion process available in today’s market. An illustrative example—resin selection...

  13. In-use Stability of Ceftaroline Fosamil in Elastomeric Home Infusion Systems and MINI-BAG Plus Containers.

    Science.gov (United States)

    Bhattacharya, Sisir; Parekh, Satish; Dedhiya, Mahendra

    2015-01-01

    The objective of this study was to determine in-use stability of ceftaroline fosamil infusion solution of concentrations up to 12 mg/mL in elastomeric home infusion system prefilled with 0.9% Sodium Chloride Injection USP or 5% Dextrose Injection USP and MINI-BAG Plus Container delivery devices prefilled with 0.9% sodium chloride injection. In-use ceftaroline fosamil infusion solution (12 mg/mL) was prepared for elastomeric home infusion systems (Homepump Eclipse, Baxter Intermate, and AccuRx Elastomeric Pump) pre-filled with either 0.9% sodium chloride injection or 5% dextrose; or Baxter MINI-BAG Plus Containers pre-filled with 0.9% Sodium Chloride Injection USP (4 mg/mL to 12 mg/mL ceftaroline fosamil in final solution). The systems were stored refrigerated for 24 hours followed by up to 6 hours of storage at room temperature. Samples were analyzed at various time points for assay and degradation product by a validated stability-indicating high-performance liquid chromatography method. In-use ceftaroline fosamil infusion solution, ranging from 4-mg/mL to a maximum of 12-mg/mL concentration, in elastomeric home infusion systems prefilled with 0.9% sodium chloride injection or 5% dextrose, and MINI-BAG Plus Containers prefilled with 0.9% sodium chloride injection were chemically stable for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours at room temperature and had acceptable compatibility with material used. Ceftaroline fosamil (4 mg/mL to 12 mg/mL) maintains its potency for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours of storage at room temperature upon reconstitution in infusion solution with 0.9% sodium chloride or 5% dextrose when used in elastomeric home infusion system and MINI-BAG Plus Containers delivery devices prefilled with 0.9% sodium chloride injection.

  14. Infusion of hypertonic saline before elective hysterectomy: effects on cytokines and stress hormones

    DEFF Research Database (Denmark)

    Kolsen-Petersen, J A; Bendtzen, K; Tonnesen, E

    2008-01-01

    Infusion of hypertonic saline provides early haemodynamic benefits and may affect the immune system. It is unknown if infusion of hypertonic saline affects plasma cytokines and stress hormones after surgery.......Infusion of hypertonic saline provides early haemodynamic benefits and may affect the immune system. It is unknown if infusion of hypertonic saline affects plasma cytokines and stress hormones after surgery....

  15. Hybrid Instruments and the Indirect Credit Method - Does it work?

    OpenAIRE

    Wiedermann-Ondrej, Nadine

    2007-01-01

    This paper analyses the possibility of double non-taxation of hybrid instruments in cross border transactions where the country of the investor has implemented the indirect credit method for mitigation or elimination of double taxation. From an isolated perspective a double non-taxation cannot be obtained because typically no taxes are paid in the foreign country due to the classification as debt and therefore even in the case of a classification as a dividend in the country of the investor n...

  16. Value of infusion-DSA (Digital Subtraction Angiography) in diagnosis of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kwon, Jeong Mi; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duk

    1991-01-01

    In order to evaluate diagnostic effectiveness of the infusion-study, the authors prospectively evaluated hepatic digital subtraction angiography of bolus and infusion studies in 71 patients with hepatocellular carcinoma. In contrast to Bolus-DSA, which involves a 2 second injection of 10cc of contrast medium, the Infusion-DSA uses a protracted (10sec) injection, a lower injection rate, and larger total dose of contrast medium (20cc). The information yield of arterial and capillary phases of Infusion-DSA was compared with that of Bolus-DSA and graded as 'improved(+)', 'equivalent( ± )', or 'poor(-)'. Also, the contribution of Infusion-DSA to the diagnosis was classified into one of five in a graded system. In 29 hepatocellular patients, the Infusion-DSA was helpful in detecting daughter nodules, fibrous capsule and arteriovenous shunt. Infusion-DSA is a useful complementary technique in the diagnosis of hepatocellular carcinoma and was also helpful in determining the selection of the therapeutic modality of hepatocellular carcinoma

  17. Mathematical model of 5-[125I]iodo-2'-deoxyuridine treatment: continuous infusion regimens for hepatic metastases

    International Nuclear Information System (INIS)

    Sgouros, George; O'Donoghue, Joseph A.; Larson, Steven M.; Macapinlac, Homer; Larson, Justine J.; Kemeny, Nancy

    1998-01-01

    Purpose: Due to the cytotoxicity of DNA-bound iodine-125, 5-[ 125 I]Iodo-2'-deoxyuridine ([ 125 I]IUdR), an analog of thymidine, has long been recognized as possessing therapeutic potential. In this work, the feasibility and potential effectiveness of hepatic artery infusion of [ 125 I]IUdR is examined. Methods: A mathematical model has been developed that simulates tumor growth and response to [ 125 I]IUdR treatment. The model is used to examine the efficacy and potential toxicity of prolonged infusion therapy. Treatment of kinetically homogeneous tumors with potential doubling times of either 4, 5, or 6 days is simulated. Assuming uniformly distributed activity, absorbed dose estimates to the red marrow, liver and whole-body are calculated to assess the potential toxicity of treatment. Results: Nine to 10 logs of tumor-cell kill over a 7- to 20-day period are predicted by the various simulations examined. The most slowly proliferating tumor was also the most difficult to eradicate. During the infusion time, tumor-cell loss consisted of two components: A plateau phase, beginning at the start of infusion and ending once the infusion time exceeded the potential doubling time of the tumor; and a rapid cell-reduction phase that was close to log-linear. Beyond the plateau phase, treatment efficacy was highly sensitive to tumor activity concentration. Conclusions: Model predictions suggest that [ 125 I]IUdR will be highly dependent upon the potential doubling time of the tumor. Significant tumor cell kill will require infusion durations that exceed the longest potential doubling time in the tumor-cell population

  18. Structural hybrid reliability index and its convergent solving method based on random–fuzzy–interval reliability model

    OpenAIRE

    Hai An; Ling Zhou; Hui Sun

    2016-01-01

    Aiming to resolve the problems of a variety of uncertainty variables that coexist in the engineering structure reliability analysis, a new hybrid reliability index to evaluate structural hybrid reliability, based on the random–fuzzy–interval model, is proposed in this article. The convergent solving method is also presented. First, the truncated probability reliability model, the fuzzy random reliability model, and the non-probabilistic interval reliability model are introduced. Then, the new...

  19. Course on hybrid calculation

    International Nuclear Information System (INIS)

    Weill, J.; Tellier; Bonnemay; Craigne; Chareton; Di Falco

    1969-02-01

    After a definition of hybrid calculation (combination of analogue and digital calculation) with a distinction between series and parallel hybrid computing, and a description of a hybrid computer structure and of task sharing between computers, this course proposes a description of hybrid hardware used in Saclay and Cadarache computing centres, and of operations performed by these systems. The next part addresses issues related to programming languages and software. The fourth part describes how a problem is organised for its processing on these computers. Methods of hybrid analysis are then addressed: resolution of optimisation problems, of partial differential equations, and of integral equations by means of different methods (gradient, maximum principle, characteristics, functional approximation, time slicing, Monte Carlo, Neumann iteration, Fischer iteration)

  20. A study on radiation therapy combined with superselective intraarterial infusion therapy for maxillary sinus carcinoma

    International Nuclear Information System (INIS)

    Okamoto, Isaku; Ito, Hiroyuki; Shimizu, Akira; Shimizu, Shigetaka; Suzuki, Mamoru; Yoshida, Tomoyuki; Nakamura, Kazuhiro; Tsukahara, Kiyoaki

    2010-01-01

    The data of 14 patients with squamous cell carcinoma of the maxillary sinus who were admitted to our hospital and received radiation therapy and concurrent superselective intraarterial infusion therapy between 1998 and 2008 were analyzed to determine the effect of the primary treatment and the adverse events. The subjects were between 43 and 79 years old (median, 61 years old), and there were 10 male and 4 female patients. Superselective intraarterial infusion therapy was administered using the Seldinger method, and cisplatin (CDDP) was administered by intraarterial infusion at a total of 200 mg/m 2 . 5-fluorouracil (FU) was systemically administered by intravenous infusion at the dose of 800 mg/m 2 from day 2 to day 5. In addition, radiation therapy was given concurrently, beginning on day 2. At 4 weeks after completion of the scheduled radiation therapy combined with superselective intraarterial infusion therapy, the treatment effect was judged based on macroscopic, radiological and histopathological findings. The response rates to the primary treatment were as follows: 57.1%, complete response (CR) (8 patients) and 42.9%, partial response (PR) (6 patients). Thus, the overall response rate was 100%. As for the adverse events, while grade 4 cerebral infarction occurred in one patient, all of the other adverse events were reversible and not serious. The safety of the treatment was therefore considered to be acceptable. We are planning to investigate the long-term outcomes in a future study. (author)

  1. A hybrid method based on a new clustering technique and multilayer perceptron neural networks for hourly solar radiation forecasting

    International Nuclear Information System (INIS)

    Azimi, R.; Ghayekhloo, M.; Ghofrani, M.

    2016-01-01

    Highlights: • A novel clustering approach is proposed based on the data transformation approach. • A novel cluster selection method based on correlation analysis is presented. • The proposed hybrid clustering approach leads to deep learning for MLPNN. • A hybrid forecasting method is developed to predict solar radiations. • The evaluation results show superior performance of the proposed forecasting model. - Abstract: Accurate forecasting of renewable energy sources plays a key role in their integration into the grid. This paper proposes a hybrid solar irradiance forecasting framework using a Transformation based K-means algorithm, named TB K-means, to increase the forecast accuracy. The proposed clustering method is a combination of a new initialization technique, K-means algorithm and a new gradual data transformation approach. Unlike the other K-means based clustering methods which are not capable of providing a fixed and definitive answer due to the selection of different cluster centroids for each run, the proposed clustering provides constant results for different runs of the algorithm. The proposed clustering is combined with a time-series analysis, a novel cluster selection algorithm and a multilayer perceptron neural network (MLPNN) to develop the hybrid solar radiation forecasting method for different time horizons (1 h ahead, 2 h ahead, …, 48 h ahead). The performance of the proposed TB K-means clustering is evaluated using several different datasets and compared with different variants of K-means algorithm. Solar datasets with different solar radiation characteristics are also used to determine the accuracy and processing speed of the developed forecasting method with the proposed TB K-means and other clustering techniques. The results of direct comparison with other well-established forecasting models demonstrate the superior performance of the proposed hybrid forecasting method. Furthermore, a comparative analysis with the benchmark solar

  2. Hybrid Finite Element and Volume Integral Methods for Scattering Using Parametric Geometry

    DEFF Research Database (Denmark)

    Volakis, John L.; Sertel, Kubilay; Jørgensen, Erik

    2004-01-01

    n this paper we address several topics relating to the development and implementation of volume integral and hybrid finite element methods for electromagnetic modeling. Comparisons of volume integral equation formulations with the finite element-boundary integral method are given in terms of accu...... of vanishing divergence within the element but non-zero curl. In addition, a new domain decomposition is introduced for solving array problems involving several million degrees of freedom. Three orders of magnitude CPU reduction is demonstrated for such applications....

  3. Dexmedetomidine infusion during middle ear surgery under general anaesthesia to provide oligaemic surgical field: A prospective study

    Directory of Open Access Journals (Sweden)

    Kumkum Gupta

    2015-01-01

    Full Text Available Background and Aims: Middle ear surgery requires bloodless surgical field for better operating conditions, deep level of anaesthesia and rapid emergence. Recent studies suggest that α2 agonists could provide desired surgical field, sedation and analgesia. The present study was aimed to evaluate the clinical effects of dexmedetomidine infusion as anaesthetic adjuvant during middle ear surgery using operating microscope. Methods: Sixty four adult patients aged 18-58 years, American Society of Anaesthesiologists Grades I and II, of both gender were randomised into two comparable equal groups of 32 patients each for middle ear surgery under general anaesthesia with standard anaesthetic technique. After induction of general anaesthesia, patients of Group I were given dexmedetomidine infusion of 0.5 μg/kg/h and patients of Group II were given placebo infusion of normal saline. Isoflurane concentration was titrated to achieve a systolic blood pressure 30% below the baseline value. All patients were assessed intra-operatively for bleeding at surgical field, haemodynamic changes, awakening time and post-operative recovery. Results: Statistically significant reduction was observed in the required percentage of isoflurane (0.8 ± 0.6% to maintain the systolic blood pressure 30% below the baseline values in patients receiving dexmedetomidine infusion when compared to those receiving placebo infusion (1.6 ± 0.7%. Patients receiving dexmedetomidine infusion had statistically significant lesser bleeding at surgical field (P < 0.05. The mean awakening time and recovery from anaesthesia did not show any significant difference between the groups. Conclusion: Dexmedetomidine infusion can be safely used to provide oligaemic surgical field for better visualization using operating microscope for middle ear surgery.

  4. Dextrose boluses versus burette dextrose infusions in prevention of ...

    African Journals Online (AJOL)

    Background: Hypoglycemia is a major cause of morbidity and mortality among preterm infants and its management remains a challenge in resource limited settings. Use of dextrose infusion by the recommended infusion pumps is not feasible in our environment due to their high costs and yet the current use of mini dextrose ...

  5. Use of the Streaming Matrix Hybrid Method for discrete-ordinates fusion reactor calculations

    International Nuclear Information System (INIS)

    Battat, M.E.; Davidson, J.W.; Dudziak, D.J.; Thayer, G.R.

    1984-01-01

    The use of the discrete-ordinates method for solving two-dimensional, neutral-particle transport in fusion reactor blankets and shields is often limited by inherent inaccuracies due to the ray-effect. This effect presents a particular problem in the case of neutron streaming in the large internal void regions of a fusion reactor. A deterministic streaming technique called the Streaming Matrix Hybrid Method (SMHM) has been incorporated in the two-dimensional discrete-ordinates code TRIDENT-CTR. Calculations have been performed for an actual inertial-confinement fusion (ICF) reactor design using TRIDENT-CTR both with and without the SMHM. Comparisons of the calculated fluxes indicate that substantial mitigation of the ray effect can be achieved with the SMHM. Calculations were performed for the Los Alamos FIRST STEP hybrid ICF reactor designed for tritium production. Conventional 238 U fuel rod assemblies surround the spherical steel target chamber to form an annular cylindrical blanket. An axial fuel region is included to complete the blanket

  6. Measuring the influence of blood component infusion rate on recipient vital signs.

    Science.gov (United States)

    Gehrie, E A; Hendrickson, J E; Tormey, C A

    2015-11-01

    One of the challenges surrounding blood component administration is the determination of an appropriate rate of infusion. There are very few evidence-based guidelines available to guide healthcare providers looking for a 'standard' infusion rate for red blood cells (RBCs), plasma or platelets (PLTs). Our objective was to determine the extent to which blood component infusion rates were associated with changes in transfusion recipient vital signs. We retrospectively examined records of 3496 component infusions (RBCs, n = 2359; PLTs, n = 478; plasma, n = 659) over a 1-year period at a 362-bed multispecialty hospital. The following data were collected for each transfusion: blood product volume and infusion time, recipient pre- and post-transfusion temperature, blood pressure and pulse rate, and hospital ward where transfusion occurred. Plasma (median 10.4 ml/min) was infused faster than PLTs (median 7.2 ml/min, P 20 ml/min) and clinically significant reported changes in vital signs. There does not appear to be a strong correlation between infusion rate and significant changes in recipient temperature, blood pressure or pulse rate. Based on these data, a reasonable rate for routine transfusion is 2-3 ml/min for RBCs and 7-10 ml/min for plasma and PLTs. Faster infusion rates (>20 ml/min) likely can be applied with close patient monitoring if there is a more urgent need for transfusion. © 2015 International Society of Blood Transfusion.

  7. Decentralized Method for Load Sharing and Power Management in a PV/Battery Hybrid Source Islanded Microgrid

    DEFF Research Database (Denmark)

    Karimi, Yaser; Oraee, Hashem; Golsorkhi, Mohammad

    2017-01-01

    This paper proposes a new decentralized power management and load sharing method for a photovoltaic based islanded microgrid consisting of various PV units, battery units and hybrid PV/battery units. Unlike the previous methods in the literature, there is no need to communication among the units......, the operation of each unit is divided into five states and modified active power-frequency droop functions are used according to operating states. The frequency level is used as trigger for switching between the states. Efficacy of the proposed method in different load, PV generation and battery conditions...... and the proposed method is not limited to the systems with separate PV and battery units or systems with only one hybrid unit. The proposed method takes into account the available PV power and battery conditions of the units to share the load among them. To cover all possible conditions of the microgrid...

  8. Hybrid massively parallel fast sweeping method for static Hamilton–Jacobi equations

    Energy Technology Data Exchange (ETDEWEB)

    Detrixhe, Miles, E-mail: mdetrixhe@engineering.ucsb.edu [Department of Mechanical Engineering (United States); University of California Santa Barbara, Santa Barbara, CA, 93106 (United States); Gibou, Frédéric, E-mail: fgibou@engineering.ucsb.edu [Department of Mechanical Engineering (United States); University of California Santa Barbara, Santa Barbara, CA, 93106 (United States); Department of Computer Science (United States); Department of Mathematics (United States)

    2016-10-01

    The fast sweeping method is a popular algorithm for solving a variety of static Hamilton–Jacobi equations. Fast sweeping algorithms for parallel computing have been developed, but are severely limited. In this work, we present a multilevel, hybrid parallel algorithm that combines the desirable traits of two distinct parallel methods. The fine and coarse grained components of the algorithm take advantage of heterogeneous computer architecture common in high performance computing facilities. We present the algorithm and demonstrate its effectiveness on a set of example problems including optimal control, dynamic games, and seismic wave propagation. We give results for convergence, parallel scaling, and show state-of-the-art speedup values for the fast sweeping method.

  9. Hybrid massively parallel fast sweeping method for static Hamilton–Jacobi equations

    International Nuclear Information System (INIS)

    Detrixhe, Miles; Gibou, Frédéric

    2016-01-01

    The fast sweeping method is a popular algorithm for solving a variety of static Hamilton–Jacobi equations. Fast sweeping algorithms for parallel computing have been developed, but are severely limited. In this work, we present a multilevel, hybrid parallel algorithm that combines the desirable traits of two distinct parallel methods. The fine and coarse grained components of the algorithm take advantage of heterogeneous computer architecture common in high performance computing facilities. We present the algorithm and demonstrate its effectiveness on a set of example problems including optimal control, dynamic games, and seismic wave propagation. We give results for convergence, parallel scaling, and show state-of-the-art speedup values for the fast sweeping method.

  10. In situ hybridization at the electron microscope level: hybrid detection by autoradiography and colloidal gold.

    Science.gov (United States)

    Hutchison, N J; Langer-Safer, P R; Ward, D C; Hamkalo, B A

    1982-11-01

    In situ hybridization has become a standard method for localizing DNA or RNA sequences in cytological preparations. We developed two methods to extend this technique to the transmission electron microscope level using mouse satellite DNA hybridization to whole mount metaphase chromosomes as the test system. The first method devised is a direct extension of standard light microscope level using mouse satellite DNA hybridization to whole mount metaphase chromosomes as the test system. The first method devised is a direct extension of standard light microscope in situ hybridization. Radioactively labeled complementary RNA (cRNA) is hybridized to metaphase chromosomes deposited on electron microscope grids and fixed in 70 percent ethanol vapor; hybridixation site are detected by autoradiography. Specific and intense labeling of chromosomal centromeric regions is observed even after relatively short exposure times. Inerphase nuclei present in some of the metaphase chromosome preparations also show defined paatterms of satellite DNA labeling which suggests that satellite-containing regions are associate with each other during interphase. The sensitivity of this method is estimated to at least as good as that at the light microscope level while the resolution is improved at least threefold. The second method, which circumvents the use of autoradiogrphic detection, uses biotin-labeled polynucleotide probes. After hybridization of these probes, either DNA or RNA, to fixed chromosomes on grids, hybrids are detected via reaction is improved at least threefold. The second method, which circumvents the use of autoradiographic detection, uses biotin-labeled polynucleotide probes. After hybridization of these probes, either DNA or RNA, to fixed chromosomes on grids, hybrids are detected via reaction with an antibody against biotin and secondary antibody adsorbed to the surface of over centromeric heterochromatin and along the associated peripheral fibers. Labeling is on average

  11. Subanesthetic, Subcutaneous Ketamine Infusion Therapy in the Treatment of Chronic Nonmalignant Pain.

    Science.gov (United States)

    Zekry, Olfat; Gibson, Stephen B; Aggarwal, Arun

    2016-06-01

    This study was designed to describe the efficacy and toxicity of subcutaneous ketamine infusions and sublingual ketamine lozenges for the treatment of chronic nonmalignant pain. Data were collected prospectively on 70 subjects managed in an academic, tertiary care hospital between 2007 and 2012 who received between 3 and 7 days of subanesthetic, subcutaneous ketamine infusion. Data were analyzed for efficacy, adverse effects, and reduction in use of opioid medication. We also analyzed whether subsequent treatment with sublingual ketamine lozenges resulted in longer-term efficacy of the beneficial effects of the initial ketamine infusion. There was a significant reduction in pain intensity measured by numerical rating scale (NRS) from mean of 6.38 before ketamine to 4.60 after ketamine (P ketamine infusion from a mean morphine equivalent dose (MMED) of 216 mg/day before ketamine to 89 mg/day after ketamine (P ketamine infusion was 59%. No subjects increased their use of opioids during their hospitalization for the ketamine infusion. A small proportion of subjects who responded to the infusion were continued on ketamine lozenges. This group was followed for between 3 months and 2 years. The use of ketamine lozenges after the infusion resulted in 31% of these subjects being able to cease their use of opioids compared with only 6% who did not receive ketamine lozenges. Eleven percent of subjects who received lozenges subsequently increased their opioid usage. Adverse effects were fairly common, but only mild, with 46% of patients experiencing light-headedness and dizziness, 25% tiredness and sedation, 12% headaches, 12% hallucinations, and 8% vivid dreams. Adverse effects were easily managed by reducing the rate of the ketamine infusion. The administration of subanesthetic, subcutaneous ketamine infusion was well tolerated, with mostly mild adverse effects and no serious adverse effects. The infusion provided significant pain relief in subjects who had failed a wide

  12. Day ahead price forecasting of electricity markets by a mixed data model and hybrid forecast method

    International Nuclear Information System (INIS)

    Amjady, Nima; Keynia, Farshid

    2008-01-01

    In a competitive electricity market, forecast of energy prices is a key information for the market participants. However, price signal usually has a complex behavior due to its nonlinearity, nonstationarity, and time variancy. In spite of all performed researches on this area in the recent years, there is still an essential need for more accurate and robust price forecast methods. In this paper, a combination of wavelet transform (WT) and a hybrid forecast method is proposed for this purpose. The hybrid method is composed of cascaded forecasters where each forecaster consists of a neural network (NN) and an evolutionary algorithms (EA). Both time domain and wavelet domain features are considered in a mixed data model for price forecast, in which the candidate input variables are refined by a feature selection technique. The adjustable parameters of the whole method are fine-tuned by a cross-validation technique. The proposed method is examined on PJM electricity market and compared with some of the most recent price forecast methods. (author)

  13. [How to promote the respect of good infusion practices by meeting health care professionals?].

    Science.gov (United States)

    Le Reste, C; Fiedler, A; Dubois, S; Dewailly, A; Le Du, I; Cogulet, V

    2016-05-01

    Health care professionals often forget that there are risks associated with infusion therapy even if it is a common care. In order to assess this practice and to draw potential improvement actions, an audit of local gravity-flow intravenous infusion practices was conducted. The audit, based on a grid including 66 items from the medical prescription to the end of the infusion therapy administration, was conducted in the 6 units which use the most gravity-flow intravenous infusion devices. A multidisciplinary working group was created to decide and organize priority corrective measures in order to improve infusion practices and quality of healthcare. The audit enabled to observe 90hours of nurse's practices (96 infusions) and highlighted heterogeneity in infusion, in some cases inappropriate infusion practices and misuse of infusion devices. We found 4 main issues: labelling infusion therapy, training of health care professionals on good practices, support the purchase of infusion pumps and standardize perfusion line. An interactive educational program for nurses (workshops) was organized to enhance the respect of good practices: infusion identification at any time, respect of hygiene rules, flow rate regulation by counting drops, appropriate use of pumps and flow rate regulators. The audit drew up work priorities. The workshops made easier exchanges between professionals and had a warm welcome that's why it is essential to carry on such training. This collaborative approach between pharmacists, nurses, hygienists and biomedical technicians contribute to drug management improvement and promote optimal patient care. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  14. Impact of infusion speed on the safety and effectiveness of prothrombin complex concentrate

    OpenAIRE

    Pabinger , Ingrid; Tiede , Andreas; Kalina , Uwe; Knaub , Sigurd; Germann , Reinhard; Ostermann , Helmut

    2009-01-01

    Abstract Prothrombin complex concentrate (PCC) infusion is preferred for emergency reversal of coumarin therapy. Rapid infusion can potentially save crucial time; however, the possible impact of high infusion speed on PCC safety and effectiveness has not been delineated. In a prospective multinational clinical trial with 43 patients receiving PCC (Beriplex? P/N) for emergency reversal of coumarin therapy, infusion speeds were selected by the investigators. In a two-phase statistica...

  15. Infusion Nursing: An Evidence-Based Approach - Third edition Alexander Mary Infusion Nursing: An Evidence-Based Approach - Third edition 625pp Elsevier 9781416064107 1416064109 [Formula: see text].

    Science.gov (United States)

    2010-11-03

    This book considers all aspects of infusion therapy and provides a solid evidence base. Its 30 chapters are well organised into six sections covering physiological considerations, infusion therapies and nursing practice.

  16. A new venous infusion path monitoring system utilizing electrostatic induced potential.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Caldwell, W Morton

    2008-01-01

    A new venous infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear and digital integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. A 330 kHz AC voltage, which is induced on the patient's body by electrostatic coupling from a 330 kHz pulse oscillator, can be recorded by main and reference electrodes wrapped around the infusion polyvinyl chloride tube. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).

  17. Haemolytic anaemia as a complication to intravenous immunoglobulin infusion

    DEFF Research Database (Denmark)

    Markvardsen, Lars Høj; Harbo, Thomas; Christiansen, Ingelise

    performed before and two weeks after infusion of IVIg. Following treatment blood haemoglobin declined from 8.6±0.8 to 8.1±1.3mmol/l, p... naive patients are susceptible to develop haemolysis. Haemolytic anaemia is a severe side effect that seems to be more frequent after immunoglobulin infusions than previously recognized....

  18. Facile method to synthesize magnetic iron oxides/TiO2 hybrid nanoparticles and their photodegradation application of methylene blue

    Directory of Open Access Journals (Sweden)

    Wu Wei

    2011-01-01

    Full Text Available Abstract Many methods have been reported to improving the photocatalytic efficiency of organic pollutant and their reliable applications. In this work, we propose a facile pathway to prepare three different types of magnetic iron oxides/TiO2 hybrid nanoparticles (NPs by seed-mediated method. The hybrid NPs are composed of spindle, hollow, and ultrafine iron oxide NPs as seeds and 3-aminopropyltriethyloxysilane as linker between the magnetic cores and TiO2 layers, respectively. The composite structure and the presence of the iron oxide and titania phase have been confirmed by transmission electron microscopy, X-ray diffraction, and X-ray photoelectron spectra. The hybrid NPs show good magnetic response, which can get together under an external applied magnetic field and hence they should become promising magnetic recovery catalysts (MRCs. Photocatalytic ability examination of the magnetic hybrid NPs was carried out in methylene blue (MB solutions illuminated under Hg light in a photochemical reactor. About 50% to 60% of MB was decomposed in 90 min in the presence of magnetic hybrid NPs. The synthesized magnetic hybrid NPs display high photocatalytic efficiency and will find recoverable potential applications in cleaning polluted water with the help of magnetic separation.

  19. Effect of intravenous N-acetylcysteine infusion on haemostatic parameters in healthy subjects

    DEFF Research Database (Denmark)

    Knudsen, TT; Thorsen, S; Jensen, SA

    2005-01-01

    BACKGROUND AND AIMS: N-acetylcysteine is used to treat paracetamol overdose but depresses the activity of plasma coagulation factors II, VII, and X, which are often used to assess liver injury. The aim of this study was to investigate the effect of N-acetylcysteine on haemostasis in normal...... volunteers. METHODS: Haemostatic parameters in 10 healthy subjects were analysed before and following intravenous infusion of therapeutic doses of N-acetylcysteine, as well as in vitro. RESULTS: N-acetylcysteine induced significant decreases in plasma levels of vitamin K dependent haemostatic proteins...... activity, and free protein S reactivity, respectively. These data suggest that N-acetylcysteine induces protein modifications affecting activity. Five subjects developed an adverse reaction to infusion of N-acetylcysteine and these were associated with a rapid increase in levels of factor VIII and its...

  20. Hybrid-DFT  +  V w method for band structure calculation of semiconducting transition metal compounds: the case of cerium dioxide.

    Science.gov (United States)

    Ivády, Viktor; Gali, Adam; Abrikosov, Igor A

    2017-11-15

    Hybrid functionals' non-local exchange-correlation potential contains a derivative discontinuity that improves on standard semi-local density functional theory (DFT) band gaps. Moreover, by careful parameterization, hybrid functionals can provide self-interaction reduced description of selected states. On the other hand, the uniform description of all the electronic states of a given system is a known drawback of these functionals that causes varying accuracy in the description of states with different degrees of localization. This limitation can be remedied by the orbital dependent exact exchange extension of hybrid functionals; the hybrid-DFT  +  V w method (Ivády et al 2014 Phys. Rev. B 90 035146). Based on the analogy of quasi-particle equations and hybrid-DFT single particle equations, here we demonstrate that parameters of hybrid-DFT  +  V w functional can be determined from approximate theoretical quasi-particle spectra without any fitting to experiment. The proposed method is illustrated on the charge self-consistent electronic structure calculation for cerium dioxide where itinerant valence states interact with well-localized 4f atomic like states, making this system challenging for conventional methods, either hybrid-DFT or LDA  +  U, and therefore allowing for a demonstration of the advantages of the proposed scheme.

  1. Role of hybrid ratio in microstructural, mechanical and sliding wear properties of the Al5083/Graphitep/Al2O3p a surface hybrid nanocomposite fabricated via friction stir processing method

    International Nuclear Information System (INIS)

    Mostafapour Asl, A.; Khandani, S.T.

    2013-01-01

    Hybrid ratio of each reinforcement phase in hybrid composite can be defined as proportion of its volume to total reinforcement volume of the composite. The hybrid ratio is an important factor which controls the participation extent of each reinforcement phase in overall properties of hybrid composites. Hence, in the present work, surface hybrid nanocomposites of Al5083/Graphite p /Al 2 O 3p with different hybrid ratios were fabricated by friction stir processing method. Subsequently, effect of hybrid ratio on microstructural, mechanical and tribological properties of the nanocomposite was investigated. Optical microscopy and scanning electron microscopy were utilized to perform microstructural observation on the samples. Hardness value measurements, tensile and pin on disk dry sliding wear tests were carried out to investigate effect of hybrid ratio on mechanical and tribological properties of the nanocomposites. Microstructural investigations displayed better distribution with less agglomeration of reinforcement for lower volume fraction of reinforcement for both alumina and graphite particles. Hardness value, yield strength, ultimate tensile strength and wear rate of the nanocomposites revealed a two stage form along with hybrid ratio variation. The results are discussed based on microstructural observations of the nanocomposites and worn surface analyses.

  2. Dopamine/TiO{sub 2} hybrid thin films prepared by the liquid phase deposition method

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez-Tauste, David [Departament de Quimica, Universitat Autonoma de Barcelona, Campus UAB, Edifici Cn, 08290 Cerdanyola del Valles, Barcelona (Spain)], E-mail: davidg@qf.uab.es; Domenech, Xavier [Departament de Quimica, Universitat Autonoma de Barcelona, Campus UAB, Edifici Cn, 08290 Cerdanyola del Valles, Barcelona (Spain); Domingo, Concepcion [Instituto de Ciencia de Materiales (CSIC), Campus UAB, 08290 Cerdanyola del Valles, Barcelona (Spain); Ayllon, Jose A. [Departament de Quimica, Universitat Autonoma de Barcelona, Campus UAB, Edifici Cn, 08290 Cerdanyola del Valles, Barcelona (Spain)

    2008-04-30

    Liquid phase deposition method is applied to one-step production of a hybrid material composed by dopamine(DA) and TiO{sub 2} anatase. An optimized amount of the enediol derivative is added to a fluoride titania precursor aqueous solution in order to entrap this modifier within the growing TiO{sub 2}, yielding a DA/TiO{sub 2} nanocomposite material. Uniform, well-adhered and brown-colored thin films are deposited on indium tin oxide covered glass substrate. The DA/TiO{sub 2} hybrid material has been characterized by infrared spectroscopy, electronic microscopy, X-ray diffraction and UV-vis spectroscopy. The formation of the hybrid material seems to be reasonably explained by linkage of different TiO{sub 2} nanocrystallites taking advantage of both enediol and amine groups of DA.

  3. Radiographic and Histologic Study After Infusion of Contrast Media into Rabbit Submandibular Gland

    International Nuclear Information System (INIS)

    Nah, Kyung Soo; Park, Tae Won

    1990-01-01

    50 submandibular glands of rabbits were examined historadiologically after infusion with normal and over volumes of physiologic saline and 5 radiographic contrast media. The results were as follows: 1. All water soluble contrast media showed similar radiographic contrasts and absorbed about 5 minutes after infusion except Telebrix 30 which took 30 minutes in both normal and overfilled glands. 2. Lipid soluble medium, Lipiodol UF had excellent radiographic contrast and could be seen on the radiograms even after 24 hours after infusion. 3. Salivary glands infused with physiologic saline didn't show any histologic changes except slight duct dilation right after infusion. 4. Telebrix 30 caused mild to moderate duct dilation and inflammation at immediate and 24 hours after infusion which was more severe in overfilled glands. At 7 days after infusion, there were mild to moderate fibrosis of the gland and areas of necrosis was seen in overfilled glands. 5. Hypaque 60% showed similar histologic reactions to Telebrix 30 except more severe tissue destruction at 7 days after infusion. 6. Urografin 60% showed mildest histologic changes among the media used in the study. 7. Biliscopin had mild duct dilation which returned to normal after 7 days but there were moderate inflammation and tissue necrosis at that time. 8. Lipiodol UF showed severe duct dilation with numerous vacuoles and there were tissue fibrosis at 7 days after infusion but no tissue necrosis was seen.

  4. Effect of sample storage time on detection of hybridization signals in Checkerboard DNA-DNA hybridization.

    Science.gov (United States)

    do Nascimento, Cássio; Muller, Katia; Sato, Sandra; Albuquerque Junior, Rubens Ferreira

    2012-04-01

    Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 °C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p  0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.

  5. In vitro viability effects on apheresis and buffy-coat derived platelets administered through infusion pumps

    Directory of Open Access Journals (Sweden)

    Sandgren P

    2014-12-01

    Full Text Available Per Sandgren,1,2 Veronica Berggren,3 Carl Westling,1,2 Viveka Stiller1 1Department of Clinical Immunology and Transfusion Medicine, Karolinska University Hospital, 2Department of Laboratory Medicine, Karolinska Institutet, 3Department of Neonatology, Karolinska University Hospital, Stockholm, SwedenBackground: Different infusion pump systems as well as gravity infusion have been widely used in neonatal transfusion. However, the limited number of published studies describing the use of infusion pumps on platelets illustrates the necessity for more robust data.Methods: To evaluate the potential in vitro effects on the cellular, metabolic, functional and phenotypic properties of platelets, we set up a four-arm paired study simultaneously comparing the use of different infusion pumps (Alaris® CC/GP with unexposed platelets. The platelet units (n=8 were either produced by the apheresis technique and suspended in 100% plasma or derived from buffy coats to yield platelet units stored in approximately 30% plasma and 70% SSP+. Fresh and 5-day old platelets were tested.Results: Regardless of the production system or storage time used, no significant differences were observed in glucose and lactate concentration, pH, adenosine triphosphate levels, response to extent of shape change, hypotonic shock response reactivity, and CD62P expression. Similarly, no differences were observed in expression of the conformational epitope on glycoprotein IIb/IIIa, determined using procaspase-activating compound 1, or in the expression of CD42b and platelet-endothelial cell adhesion molecule-1 in a comparison between platelets administered through infusion pumps versus unexposed platelets.Conclusion: Using Alaris CC/GP infusion pumps had no influence on the cellular, functional, and phenotypic in vitro properties of platelets. This fact seems not to be affected by different production systems or storage time.Keywords: platelets, neonatal platelet transfusion

  6. The effect of tubing dwell time on insulin adsorption during intravenous insulin infusions.

    Science.gov (United States)

    Thompson, Cecilia D; Vital-Carona, Jessica; Faustino, E Vincent S

    2012-10-01

    Insulin adsorbs to plastic tubing, which decreases the concentration of an insulin solution delivered from an intravenous infusion set. Dwelling insulin within tubing before starting the infusion decreases adsorption but delays treatment initiation and wastes time in infusion preparation. The lack of data on dwell time effects results in wide variability in practice. We aim to determine the effect of dwell time on insulin concentration from intravenous infusion tubing. In this in vitro study, we used insulin solutions with concentrations of 0.1 unit/mL, 1 unit/mL, and 10 units/mL. Each solution dwelled in intravenous infusion sets for 0, 15, 30, or 60 min. After the dwell, we measured insulin concentrations from the solution bags and tubing. We repeated each insulin concentration-dwell time combination five times. Comparisons were performed using analyses of variance. For each of the three insulin concentrations, the mean insulin concentrations from the tubing were not significantly different between dwell times. Duration of dwell time did not affect insulin adsorption in polypropylene intravenous infusion sets. We recommend that following a 20-mL flush, insulin infusions can be started without any dwell time. Removal of dwell times may improve clinical practice by minimizing preparation time and will allow faster initiation of insulin infusion therapy.

  7. Antioxidant and Antibacterial Activity of Kombucha Beverages Prepared using Banana Peel, Common Nettles and Black Tea Infusions

    Directory of Open Access Journals (Sweden)

    Ali Ebrahimi Pure

    2016-03-01

    Full Text Available Backgrounds and Objective: Kombucha is a several thousand years old traditional fermented beverage originated from East. While black tea infusion is the common substrate for preparing kombucha, other herbal infusions can be applied for this reason too. Common medicinal herbs or even waste herbal materials, like banana peel, could be suitable substrates for preparing kombucha analogues. In this study, kombuchas were fermented using nettles leaf and banana peel infusions. Materials and Methods: Herbal infusions were fermented by kombucha fungi. Folin-Ciocalteu assay was performed to evaluate total phenolic contents; Free radical scavenging activity was evaluated using 2,2-diphenyl-1-picrylhydrazyl. Disk diffusion method was performed to measure inhibitory activity against testing bacteria. All data were statistically analyzed by ANOVA test at significant level of p≤0.05. Results and Conclusion: Black tea contained highest amount of phenolics (530.5 ppm gallic acid equivalent and fermentation decomposed approximately 50% of phenolic contents to 265.5 ppm while phenolic content of nettles infusion and fermented beverage were 173 gAE and 188 gAE respectively and for banana peel, 136.5 gAE and 155 gAE; it indicated increase of phenolic contents due to fermentation that may be cause of protein contents of nettles and banana peel gone under fermentation by lactic acid bacteria. Fermented beverage of three herbs had higher antioxidant potent than infusions. Kombucha from banana peel showed the highest antioxidant activity by inhibiting 94.62% of DPPH. While antioxidant activity of fermented beverages of black tea and nettles leaf were more related to their acetic acid content, it was found that a considerable part of antioxidant activity of banana peel kombucha was due to other acids and phenolics. No antibacterial activity was observed from either of samples. Banana peel, as a waste herbal material, and nettles leaf are good ingredients for being

  8. Choice of infusion-sampling mode for tracer studies of free fatty acid metabolism

    International Nuclear Information System (INIS)

    Jensen, M.D.; Rogers, P.J.; Ellman, M.G.; Miles, J.M.

    1988-01-01

    To determine the preferred infusion-sampling mode for isotopic studies of free fatty acid (FFA) metabolism, tracer [( 14 C]palmitate) was infused into the left ventricle of five anesthetized dogs, and tracee ([ 3 H]palmitate) was infused into three separate peripheral veins of each dog. The [ 14 C]palmitate specific activity (SA) was lower in mixed venous than arterial blood, and [ 3 H]palmitate SA was equal in both sites. The actual infusion rate of [ 3 H]palmitate [2.15 +/- 0.31 X 10(5) disintegrations/min (dpm).kg-1.min-1] could be accurately predicted (2.14 +/- 0.32 X 10(5) dpm.kg-1.min-1) using the known [ 14 C]palmitate infusion rate and the arterial plasma [ 14 C]-to-[ 3 H]palmitate ratio. In contrast, the mixed venous [ 14 C]-to-[ 3 H]palmitate ratio resulted in overestimates (P less than 0.05) of the actual [ 3 H]palmitate infusion rate. In summary, venous tracer infusion with arterial blood sampling for FFA tracer studies provides the most accurate estimates of tracee rate of appearance

  9. Infusion and sampling site effects on two-pool model estimates of leucine metabolism

    International Nuclear Information System (INIS)

    Helland, S.J.; Grisdale-Helland, B.; Nissen, S.

    1988-01-01

    To assess the effect of site of isotope infusion on estimates of leucine metabolism infusions of alpha-[4,5-3H]ketoisocaproate (KIC) and [U- 14 C]leucine were made into the left or right ventricles of sheep and pigs. Blood was sampled from the opposite ventricle. In both species, left ventricular infusions resulted in significantly lower specific radioactivities (SA) of [ 14 C]leucine and [ 3 H]KIC. [ 14 C]KIC SA was found to be insensitive to infusion and sampling sites. [ 14 C]KIC was in addition found to be equal to the SA of [ 14 C]leucine only during the left heart infusions. Therefore, [ 14 C]KIC SA was used as the only estimate for [ 14 C]SA in the equations for the two-pool model. This model eliminated the influence of site of infusion and blood sampling on the estimates for leucine entry and reduced the impact on the estimates for proteolysis and oxidation. This two-pool model could not compensate for the underestimation of transamination reactions occurring during the traditional venous isotope infusion and arterial blood sampling

  10. Improved arterial blood oxygenation following intravenous infusion of cold supersaturated dissolved oxygen solution.

    Science.gov (United States)

    Grady, Daniel J; Gentile, Michael A; Riggs, John H; Cheifetz, Ira M

    2014-01-01

    One of the primary goals of critical care medicine is to support adequate gas exchange without iatrogenic sequelae. An emerging method of delivering supplemental oxygen is intravenously rather than via the traditional inhalation route. The objective of this study was to evaluate the gas-exchange effects of infusing cold intravenous (IV) fluids containing very high partial pressures of dissolved oxygen (>760 mm Hg) in a porcine model. Juvenile swines were anesthetized and mechanically ventilated. Each animal received an infusion of cold (13 °C) Ringer's lactate solution (30 mL/kg/hour), which had been supersaturated with dissolved oxygen gas (39.7 mg/L dissolved oxygen, 992 mm Hg, 30.5 mL/L). Arterial blood gases and physiologic measurements were repeated at 15-minute intervals during a 60-minute IV infusion of the supersaturated dissolved oxygen solution. Each animal served as its own control. Five swines (12.9 ± 0.9 kg) were studied. Following the 60-minute infusion, there were significant increases in PaO2 and SaO2 (P < 0.05) and a significant decrease in PaCO2 (P < 0.05), with a corresponding normalization in arterial blood pH. Additionally, there was a significant decrease in core body temperature (P < 0.05) when compared to the baseline preinfusion state. A cold, supersaturated dissolved oxygen solution may be intravenously administered to improve arterial blood oxygenation and ventilation parameters and induce a mild therapeutic hypothermia in a porcine model.

  11. Behaviour of homologous 125I fibrinogen after thrombin and ancrod infusion in rabbits

    International Nuclear Information System (INIS)

    Setter, R.

    1977-01-01

    The behaviour of radioactively labelled fibrinogen after infusion of thrombin or ancrod is investigated. Common factors and differences in the behaviour of fibrinogen after infusion of these two enzymes, which act proteolytically on the fibrinogen, are dealt with. Rabbits received an i.v. injection of homologous 125 I-fibrinogen 3 days before ancrod or thrombin infusion. On the day of the experiments, one group of animals received an ancrod infusion (1.5 U/kg body weight for 30 minutes), the other a thrombin infusion (600 U/kg body weight for 60 minutes). Intravenous ancrod and thrombin infusions lowered the fibrinogen level to 30% or 50% of the initial value due to intravascular coagulation. About 50% of the 125 I fibrinogen was transformed after ancrod exposure into a non-coagulating fraction of fibrinogen derivatives which produces no fibrinolytic decomposition products. (orig./AJ) [de

  12. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    Science.gov (United States)

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements

  13. The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling.

    Science.gov (United States)

    Mohseni, Masood; Ebneshahidi, Amin

    2014-05-01

    One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an elastomeric pump available in our market. We examined 10 elastomeric infusion pumps (BOT-802, Nanchang Biotek Medical Device Company, China) with 100 mL capacity and nominal flow of 5 mL/h. Each pump was filled for three times, accounting for 30 series of experiments. A microset scaled in mL was used to measure the pump deliveries. Flow profile and reliability of infusion rate were analyzed after repeated use. The mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not statistically significant (5.01 ± 0.07 vs. 5.03 ± 0.06 vs. 5.06 ± 0.08 mL/h; P = 0.81). The percentage of the flow rate error (deviation from 5 mL/h ± 15%) was 100% in the first and second hours of infusion, 96% in the third hour, 60% in the 20th hour and zero percent in the rest of the infusion time. This study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. These laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia.

  14. Physics-based hybrid method for multiscale transport in porous media

    Science.gov (United States)

    Yousefzadeh, Mehrdad; Battiato, Ilenia

    2017-09-01

    Despite advancements in the development of multiscale models for flow and reactive transport in porous media, the accurate, efficient and physics-based coupling of multiple scales in hybrid models remains a major theoretical and computational challenge. Improving the predictivity of macroscale predictions by means of multiscale algorithms relative to classical at-scale models is the primary motivation for the development of multiscale simulators. Yet, very few are the quantitative studies that explicitly address the predictive capability of multiscale coupling algorithms as it is still generally not possible to have a priori estimates of the errors that are present when complex flow processes are modeled. We develop a nonintrusive pore-/continuum-scale hybrid model whose coupling error is bounded by the upscaling error, i.e. we build a predictive tightly coupled multiscale scheme. This is accomplished by slightly enlarging the subdomain where continuum-scale equations are locally invalid and analytically defining physics-based coupling conditions at the interfaces separating the two computational sub-domains, while enforcing state variable and flux continuity. The proposed multiscale coupling approach retains the advantages of domain decomposition approaches, including the use of existing solvers for each subdomain, while it gains flexibility in the choice of the numerical discretization method and maintains the coupling errors bounded by the upscaling error. We implement the coupling in finite volumes and test the proposed method by modeling flow and transport through a reactive channel and past an array of heterogeneously reactive cylinders.

  15. Effect of intravenous infusion of glyceryl trinitrate on gastric and small intestinal motor function in healthy humans

    DEFF Research Database (Denmark)

    Madsen, Jan Lysgård; Fuglsang, Stefan; Graff, J

    2006-01-01

    : To examine the effect of intravenous infusion of glyceryl trinitrate on gastric and small intestinal motor function after a meal in healthy humans. METHODS: Nine healthy volunteers participated in a placebo-controlled, double-blind, crossover study. Each volunteer was examined during intravenous infusion...... of glyceryl trinitrate 1 microg/kg x min or saline. A gamma camera technique was used to measure gastric emptying and small intestinal transit after a 1600-kJ mixed liquid and solid meal. Furthermore, duodenal motility was assessed by manometry. RESULTS: Glyceryl trinitrate did not change gastric mean...... emptying time, gastric half emptying time, gastric retention at 15 min or small intestinal mean transit time. Glyceryl trinitrate did not influence the frequency of duodenal contractions, the amplitude of duodenal contractions or the duodenal motility index. CONCLUSIONS: Intravenous infusion of glyceryl...

  16. Safety and efficacy of gas-forced infusion (air pump) in coaxial phacoemulsification.

    Science.gov (United States)

    Chaudhry, Prashaant; Prakash, Gaurav; Jacob, Soosan; Narasimhan, Smita; Agarwal, Sunita; Agarwal, Amar

    2010-12-01

    To evaluate the safety and efficacy of gas-forced infusion (air pump) in uncomplicated coaxial phacoemulsification. Dr. Agarwal's Eye Hospital, Chennai, India. Comparative case series. Specular microscopy and optical coherence tomography were used to analyze the endothelium, central macular thickness (CMT), and peripapillary retinal nerve fiber layer (RNFL) thickness before and approximately 1, 7, 30, and 90 days after coaxial phacoemulsification with (infusion group) or without (control group) gas-forced infusion. Surgical time, surge, phaco energy, irrigation fluid volume, surgical ease, complications, and visual gain in the 2 groups were compared. The mean endothelial cell loss was lower in the infusion group than in the control group (6.98% ± 8.46% [SD] versus 10.54% ± 11.24%; P = .045) and the irrigation/aspiration time significantly shorter (54 ± 39 seconds versus 105 ± 84 seconds; P = .0001). The surgery was rated as easier with gas-forced infusion (scale 1 to 10: mean 8.3 ± 2.1 versus 6.6 ± 1.6; P = .00002). However, the amount of irrigating fluid volume was higher in the infusion group (117 ± 37 mL versus 94 ± 41 mL; P = .003). No surge occurred in the infusion group; it occurred a mean of 3.00 ± 4.16 times in the control group (PGas-forced infusion was safe and effective in controlling surge and increased the safety, ease, and speed of coaxial phacoemulsification. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Inheritance of spike length in F3, F4 and F5 wheat hybrids obtained by different selection methods

    Directory of Open Access Journals (Sweden)

    Janković Snežana

    2012-01-01

    Full Text Available This study analyses the mode of inheritance of spike length in F3, F4 and F5 wheat hybrids obtained by pedigree, bulk and modified pedigree method of selection. Wheat hybrids were produced after crossing five varieties by M x N method. Three varieties were used as a female parent (Briscard, Carifen 12 and Rescler and two as a male component (Francuska and PKB-Prelivka. Descendents in F2 generation were produced from 6 F1 hybrids (3 x 2. Selection after F2 generation were undertaken from 1996 to 1999, while in 2000 the field experiments with complete breeding material were set up at the Institute 'PKB INI Agroekonomik' in Padinska Skela near Belgrade. Spike length was measured in progeny generations, from F3 to F5. It was observed that progenies had higher values for spike length than better parent (BP, with longer spikes in 5 out of 6 analyzed hybrids: Briscard x PKB-Prelivka, Carifen 12 x Francuska, Carifen 12 x PKB-Prelivka, Rescler x Francuska, and Rescler x PKB-Prelivka. From the above mentioned hybrid combinations, only Rescler x Francuska descendents in F5 generation obtained by pedigree and bulk selection inherited the spike length from the parent with lower value. High significant interaction was observed for spike length between genotype and generation of progenies in each of the applied selection methods.

  18. Efficacy and Safety of Pertuzumab and Trastuzumab Administered in a Single Infusion Bag, Followed by Vinorelbine

    DEFF Research Database (Denmark)

    Andersson, Michael; López-Vega, José M; Petit, Thierry

    2017-01-01

    BACKGROUND: VELVET Cohort 1 demonstrated the applicability of pertuzumab, trastuzumab, and vinorelbine as an alternative first-line treatment regimen for patients with HER2-positive locally advanced or metastatic breast cancer (MBC) who cannot receive docetaxel. Co-infusion of pertuzumab and tras......BACKGROUND: VELVET Cohort 1 demonstrated the applicability of pertuzumab, trastuzumab, and vinorelbine as an alternative first-line treatment regimen for patients with HER2-positive locally advanced or metastatic breast cancer (MBC) who cannot receive docetaxel. Co-infusion of pertuzumab...... and trastuzumab may reduce clinic time and medical resource utilization. We report results from Cohort 2, in which pertuzumab and trastuzumab were co-infused, followed by vinorelbine. PATIENTS AND METHODS: During cycle 1, patients with HER2-positive locally advanced or MBC received loading doses of pertuzumab...... (840 mg) and trastuzumab (8 mg/kg) on consecutive days, followed by vinorelbine (25 mg/m(2)) on days two and nine. From cycle 2 onwards, patients received a co-infusion of pertuzumab (420 mg) and trastuzumab (6 mg/kg) on day one, followed by vinorelbine (30-35 mg/m(2)) on days one and eight (or days...

  19. The suitability of the simplified method of the analysis of coffee infusions on the content of Ca, Cu, Fe, Mg, Mn and Zn and the study of the effect of preparation conditions on the leachability of elements into the coffee brew.

    Science.gov (United States)

    Stelmach, Ewelina; Pohl, Pawel; Szymczycha-Madeja, Anna

    2013-12-01

    A fast and straightforward method of the analysis of coffee infusions was developed for measurements of total concentrations of Ca, Cu, Fe, Mg, Mn and Zn by flame atomic absorption spectrometry. Its validity was proved by the analysis of spiked samples; recoveries of added metals were found to be within 98-104% while the precision was better than 4%. The method devised was used for the analysis of re-distilled water infusions of six popular ground coffees available in the Polish market. Using the mud coffee preparation it was established that percentages of metals leached in these conditions varied a lot among analysed coffees, especially for Ca (14-42%), Mg (6-25%) and Zn (1-24%). For remaining metals, the highest extractabilities were assessed for Mn (30-52%) while the lowest for Fe (4-16%) and Cu (2-12%). In addition, it was found that the water type and the coffee brewing preparation method influence the concentration of studied metals in coffee infusions the most. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Hybrid Control Method for a Single Phase PFC using a Low Cost Microcontroller

    DEFF Research Database (Denmark)

    Jakobsen, Lars Tønnes; Nielsen, Nils; Wolf, Christian

    2005-01-01

    This paper presents a hybrid control method for single phase boost PFCs. The high bandwidth current loop is analog while the voltage loop is implemented in an 8-bit microcontroller. The design focuses on minimizing the number of calculations done in the microcontroller. A 1kW prototype has been...