WorldWideScience

Sample records for human hand kinetics

  1. The Kinetics Human Action Video Dataset

    OpenAIRE

    Kay, Will; Carreira, Joao; Simonyan, Karen; Zhang, Brian; Hillier, Chloe; Vijayanarasimhan, Sudheendra; Viola, Fabio; Green, Tim; Back, Trevor; Natsev, Paul; Suleyman, Mustafa; Zisserman, Andrew

    2017-01-01

    We describe the DeepMind Kinetics human action video dataset. The dataset contains 400 human action classes, with at least 400 video clips for each action. Each clip lasts around 10s and is taken from a different YouTube video. The actions are human focussed and cover a broad range of classes including human-object interactions such as playing instruments, as well as human-human interactions such as shaking hands. We describe the statistics of the dataset, how it was collected, and give some ...

  2. Kinematic and kinetic differences between left-and right-handed professional baseball pitchers.

    Science.gov (United States)

    Diffendaffer, Alek Z; Fleisig, Glenn S; Ivey, Brett; Aune, Kyle T

    2018-03-21

    While 10% of the general population is left-handed, 27% of professional baseball pitchers are left-handed. Biomechanical differences between left- and right-handed college pitchers have been previously reported, but these differences have yet to be examined at the professional level. Therefore, the purpose of this study was to compare pitching biomechanics between left- and right-handed professional pitchers. It was hypothesised that there would be significant kinematic and kinetic differences between these two groups. Pitching biomechanics were collected on 96 left-handed pitchers and a group of 96 right-handed pitchers matched for age, height, mass and ball velocity. Student t-tests were used to identify kinematic and kinetic differences (p different between the groups. Landing position of the stride foot, trunk separation at foot contact, maximum shoulder external rotation and trunk forward tilt at ball release were all significantly greater in right-handed pitchers. The magnitude of the statistical differences found were small and not consistent with differences in the two previous, smaller studies. Thus, the differences found may be of minimal practical significance and mechanics can be taught the same to all pitchers, regardless of throwing hand.

  3. The human hand as an inspiration for robot hand development

    CERN Document Server

    Santos, Veronica

    2014-01-01

    “The Human Hand as an Inspiration for Robot Hand Development” presents an edited collection of authoritative contributions in the area of robot hands. The results described in the volume are expected to lead to more robust, dependable, and inexpensive distributed systems such as those endowed with complex and advanced sensing, actuation, computation, and communication capabilities. The twenty-four chapters discuss the field of robotic grasping and manipulation viewed in light of the human hand’s capabilities and push the state-of-the-art in robot hand design and control. Topics discussed include human hand biomechanics, neural control, sensory feedback and perception, and robotic grasp and manipulation. This book will be useful for researchers from diverse areas such as robotics, biomechanics, neuroscience, and anthropologists.

  4. Constraint Study for a Hand Exoskeleton: Human Hand Kinematics and Dynamics

    Directory of Open Access Journals (Sweden)

    Fai Chen Chen

    2013-01-01

    Full Text Available In the last few years, the number of projects studying the human hand from the robotic point of view has increased rapidly, due to the growing interest in academic and industrial applications. Nevertheless, the complexity of the human hand given its large number of degrees of freedom (DoF within a significantly reduced space requires an exhaustive analysis, before proposing any applications. The aim of this paper is to provide a complete summary of the kinematic and dynamic characteristics of the human hand as a preliminary step towards the development of hand devices such as prosthetic/robotic hands and exoskeletons imitating the human hand shape and functionality. A collection of data and constraints relevant to hand movements is presented, and the direct and inverse kinematics are solved for all the fingers as well as the dynamics; anthropometric data and dynamics equations allow performing simulations to understand the behavior of the finger.

  5. Kinetic study of human hand sodium using local in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Cohen Boulakia, Francine.

    1978-01-01

    Using local 'in vivo' activation analysis, turnover of human hand sodium is studied in 14 subjects, 7 controls and 7 decalcified osteoporotics patients. The hand of each subject is irradiated with neutrons emitted by 52 Cf sources; the equivalent dose delivered is 8 cGy. The 24 Na activity variation is plotted as function of time and the experimental curve so obtained is fitted to two exponentials. Two compartements are identified: a rapidly exchangeable one, with a half life of 1 h; an other, with a very slow turnover, the half lifes varying from 79 h to 35 h as the calcium concentration becomes sub-normal. The ratios calcium to slowly exchangeable sodium and rapidly to slowly exchangeable sodium appear to be promising for the evaluation of bone disease [fr

  6. Sensing human hand motions for controlling dexterous robots

    Science.gov (United States)

    Marcus, Beth A.; Churchill, Philip J.; Little, Arthur D.

    1988-01-01

    The Dexterous Hand Master (DHM) system is designed to control dexterous robot hands such as the UTAH/MIT and Stanford/JPL hands. It is the first commercially available device which makes it possible to accurately and confortably track the complex motion of the human finger joints. The DHM is adaptable to a wide variety of human hand sizes and shapes, throughout their full range of motion.

  7. HUMAN HAND STUDY FOR ROBOTIC EXOSKELETON DELVELOPMENT

    OpenAIRE

    BIROUAS Flaviu Ionut; NILGESZ Arnold

    2016-01-01

    This paper will be presenting research with application in the rehabilitation of hand motor functions by the aid of robotics. The focus will be on the dimensional parameters of the biological human hand from which the robotic system will be developed. The term used for such measurements is known as anthropometrics. The anthropometric parameters studied and presented in this paper are mainly related to the angular limitations of the finger joints of the human hand.

  8. HUMAN HAND STUDY FOR ROBOTIC EXOSKELETON DELVELOPMENT

    Directory of Open Access Journals (Sweden)

    BIROUAS Flaviu Ionut

    2016-11-01

    Full Text Available This paper will be presenting research with application in the rehabilitation of hand motor functions by the aid of robotics. The focus will be on the dimensional parameters of the biological human hand from which the robotic system will be developed. The term used for such measurements is known as anthropometrics. The anthropometric parameters studied and presented in this paper are mainly related to the angular limitations of the finger joints of the human hand.

  9. Human Hand Motion Analysis and Synthesis of Optimal Power Grasps for a Robotic Hand

    Directory of Open Access Journals (Sweden)

    Francesca Cordella

    2014-03-01

    Full Text Available Biologically inspired robotic systems can find important applications in biomedical robotics, since studying and replicating human behaviour can provide new insights into motor recovery, functional substitution and human-robot interaction. The analysis of human hand motion is essential for collecting information about human hand movements useful for generalizing reaching and grasping actions on a robotic system. This paper focuses on the definition and extraction of quantitative indicators for describing optimal hand grasping postures and replicating them on an anthropomorphic robotic hand. A motion analysis has been carried out on six healthy human subjects performing a transverse volar grasp. The extracted indicators point to invariant grasping behaviours between the involved subjects, thus providing some constraints for identifying the optimal grasping configuration. Hence, an optimization algorithm based on the Nelder-Mead simplex method has been developed for determining the optimal grasp configuration of a robotic hand, grounded on the aforementioned constraints. It is characterized by a reduced computational cost. The grasp stability has been tested by introducing a quality index that satisfies the form-closure property. The grasping strategy has been validated by means of simulation tests and experimental trials on an arm-hand robotic system. The obtained results have shown the effectiveness of the extracted indicators to reduce the non-linear optimization problem complexity and lead to the synthesis of a grasping posture able to replicate the human behaviour while ensuring grasp stability. The experimental results have also highlighted the limitations of the adopted robotic platform (mainly due to the mechanical structure to achieve the optimal grasp configuration.

  10. Epinephrine kinetics in humans: Radiotracer methodology

    International Nuclear Information System (INIS)

    Rosen, S.G.; Linares, O.A.; Sanfield, J.A.; Zech, L.A.; Lizzio, V.P.; Halter, J.B.

    1989-01-01

    The use of the plasma epinephrine (EPI) level as an index of adrenomedullary activity in humans is complicated by the rapid removal of EPI from plasma by many tissues. To determine whether the kinetics of distribution and metabolism of EPI could be best quantified using the isotope dilution method or a mathematical modeling technique, eight human subjects received a [ 3 H]EPI infusion for 50-60 min. Analysis of the steady state arterialized plasma levels of EPI and [ 3 H]EPI using the isotope dilution technique showed that the basal plasma EPI appearance rate is 0.87 ± 0.11 nmol/m2.min, and the basal plasma EPI clearance rate is 1.63 ± 0.14 L/min.m2. Mathematical modeling of the [ 3 H]EPI levels revealed that a biexponential curve fit was superior to monoexponential and triexponential curve fits. A two-compartment model was the minimal compartment model that accurately described EPI kinetics. The basal plasma EPI appearance (0.82 ± 0.16 nmol/m2.min) and EPI clearance (1.67 ± 0.15 L/min.m2) rates that were estimated from this two-compartment model are similar to the results derived from the isotope dilution method. Mathematical modeling revealed a large extravascular mass of EPI. We conclude that the isotope dilution and mathematical modeling techniques similarly describe plasma EPI kinetics in humans. Kinetic analysis using mathematical modeling provides new insights into adrenomedullary function in humans

  11. Approaching human performance the functionality-driven Awiwi robot hand

    CERN Document Server

    Grebenstein, Markus

    2014-01-01

    Humanoid robotics have made remarkable progress since the dawn of robotics. So why don't we have humanoid robot assistants in day-to-day life yet? This book analyzes the keys to building a successful humanoid robot for field robotics, where collisions become an unavoidable part of the game. The author argues that the design goal should be real anthropomorphism, as opposed to mere human-like appearance. He deduces three major characteristics to aim for when designing a humanoid robot, particularly robot hands: _ Robustness against impacts _ Fast dynamics _ Human-like grasping and manipulation performance   Instead of blindly copying human anatomy, this book opts for a holistic design me-tho-do-lo-gy. It analyzes human hands and existing robot hands to elucidate the important functionalities that are the building blocks toward these necessary characteristics.They are the keys to designing an anthropomorphic robot hand, as illustrated in the high performance anthropomorphic Awiwi Hand presented in this book.  ...

  12. User Interface Aspects of a Human-Hand Simulation System

    Directory of Open Access Journals (Sweden)

    Beifang Yi

    2005-10-01

    Full Text Available This paper describes the user interface design for a human-hand simulation system, a virtual environment that produces ground truth data (life-like human hand gestures and animations and provides visualization support for experiments on computer vision-based hand pose estimation and tracking. The system allows users to save time in data generation and easily create any hand gestures. We have designed and implemented this user interface with the consideration of usability goals and software engineering issues.

  13. 3D Visual Sensing of the Human Hand for the Remote Operation of a Robotic Hand

    Directory of Open Access Journals (Sweden)

    Pablo Gil

    2014-02-01

    Full Text Available New low cost sensors and open free libraries for 3D image processing are making important advances in robot vision applications possible, such as three-dimensional object recognition, semantic mapping, navigation and localization of robots, human detection and/or gesture recognition for human-machine interaction. In this paper, a novel method for recognizing and tracking the fingers of a human hand is presented. This method is based on point clouds from range images captured by a RGBD sensor. It works in real time and it does not require visual marks, camera calibration or previous knowledge of the environment. Moreover, it works successfully even when multiple objects appear in the scene or when the ambient light is changed. Furthermore, this method was designed to develop a human interface to control domestic or industrial devices, remotely. In this paper, the method was tested by operating a robotic hand. Firstly, the human hand was recognized and the fingers were detected. Secondly, the movement of the fingers was analysed and mapped to be imitated by a robotic hand.

  14. Human-inspired feedback synergies for environmental interaction with a dexterous robotic hand.

    Science.gov (United States)

    Kent, Benjamin A; Engeberg, Erik D

    2014-11-07

    Effortless control of the human hand is mediated by the physical and neural couplings inherent in the structure of the hand. This concept was explored for environmental interaction tasks with the human hand, and a novel human-inspired feedback synergy (HFS) controller was developed for a robotic hand which synchronized position and force feedback signals to mimic observed human hand motions. This was achieved by first recording the finger joint motion profiles of human test subjects, where it was observed that the subjects would extend their fingers to maintain a natural hand posture when interacting with different surfaces. The resulting human joint angle data were used as inspiration to develop the HFS controller for the anthropomorphic robotic hand, which incorporated finger abduction and force feedback in the control laws for finger extension. Experimental results showed that by projecting a broader view of the tasks at hand to each specific joint, the HFS controller produced hand motion profiles that closely mimic the observed human responses and allowed the robotic manipulator to interact with the surfaces while maintaining a natural hand posture. Additionally, the HFS controller enabled the robotic hand to autonomously traverse vertical step discontinuities without prior knowledge of the environment, visual feedback, or traditional trajectory planning techniques.

  15. Human-inspired feedback synergies for environmental interaction with a dexterous robotic hand

    International Nuclear Information System (INIS)

    Kent, Benjamin A; Engeberg, Erik D

    2014-01-01

    Effortless control of the human hand is mediated by the physical and neural couplings inherent in the structure of the hand. This concept was explored for environmental interaction tasks with the human hand, and a novel human-inspired feedback synergy (HFS) controller was developed for a robotic hand which synchronized position and force feedback signals to mimic observed human hand motions. This was achieved by first recording the finger joint motion profiles of human test subjects, where it was observed that the subjects would extend their fingers to maintain a natural hand posture when interacting with different surfaces. The resulting human joint angle data were used as inspiration to develop the HFS controller for the anthropomorphic robotic hand, which incorporated finger abduction and force feedback in the control laws for finger extension. Experimental results showed that by projecting a broader view of the tasks at hand to each specific joint, the HFS controller produced hand motion profiles that closely mimic the observed human responses and allowed the robotic manipulator to interact with the surfaces while maintaining a natural hand posture. Additionally, the HFS controller enabled the robotic hand to autonomously traverse vertical step discontinuities without prior knowledge of the environment, visual feedback, or traditional trajectory planning techniques. (paper)

  16. Right-handed fossil humans.

    Science.gov (United States)

    Lozano, Marina; Estalrrich, Almudena; Bondioli, Luca; Fiore, Ivana; Bermúdez de Castro, José-Maria; Arsuaga, Juan Luis; Carbonell, Eudald; Rosas, Antonio; Frayer, David W

    2017-11-01

    Fossil hominids often processed material held between their upper and lower teeth. Pulling with one hand and cutting with the other, they occasionally left impact cut marks on the lip (labial) surface of their incisors and canines. From these actions, it possible to determine the dominant hand used. The frequency of these oblique striations in an array of fossil hominins documents the typically modern pattern of 9 right- to 1 left-hander. This ratio among living Homo sapiens differs from that among chimpanzees and bonobos and more distant primate relatives. Together, all studies of living people affirm that dominant right-handedness is a uniquely modern human trait. The same pattern extends deep into our past. Thus far, the majority of inferred right-handed fossils come from Europe, but a single maxilla from a Homo habilis, OH-65, shows a predominance of right oblique scratches, thus extending right-handedness into the early Pleistocene of Africa. Other studies show right-handedness in more recent African, Chinese, and Levantine fossils, but the sample compiled for non-European fossil specimens remains small. Fossil specimens from Sima del los Huesos and a variety of European Neandertal sites are predominately right-handed. We argue the 9:1 handedness ratio in Neandertals and the earlier inhabitants of Europe constitutes evidence for a modern pattern of handedness well before the appearance of modern Homo sapiens. © 2017 Wiley Periodicals, Inc.

  17. A natural human hand model

    NARCIS (Netherlands)

    Van Nierop, O.A.; Van der Helm, A.; Overbeeke, K.J.; Djajadiningrat, T.J.P.

    2007-01-01

    We present a skeletal linked model of the human hand that has natural motion. We show how this can be achieved by introducing a new biology-based joint axis that simulates natural joint motion and a set of constraints that reduce an estimated 150 possible motions to twelve. The model is based on

  18. Centre-surround organization of fast sensorimotor integration in human motor hand area

    DEFF Research Database (Denmark)

    Dubbioso, Raffaele; Raffin, Estelle; Karabanov, Anke

    2017-01-01

    Using the short-latency afferent inhibition (SAI) paradigm, transcranial magnetic stimulation (TMS) of the primary motor hand area (M1HAND) can probe how sensory input from limbs modulates corticomotor output in humans. Here we applied a novel TMS mapping approach to chart the spatial representat......Using the short-latency afferent inhibition (SAI) paradigm, transcranial magnetic stimulation (TMS) of the primary motor hand area (M1HAND) can probe how sensory input from limbs modulates corticomotor output in humans. Here we applied a novel TMS mapping approach to chart the spatial...... in M1HAND. Like homotopic SAI, heterotopic SAF was somatotopically expressed in M1HAND. Together, the results provide first-time evidence that fast sensorimotor integration involves centre-inhibition and surround-facilitation in human M1HAND....

  19. Durable Tactile Glove for Human or Robot Hand

    Science.gov (United States)

    Butzer, Melissa; Diftler, Myron A.; Huber, Eric

    2010-01-01

    A glove containing force sensors has been built as a prototype of tactile sensor arrays to be worn on human hands and anthropomorphic robot hands. The force sensors of this glove are mounted inside, in protective pockets; as a result of this and other design features, the present glove is more durable than earlier models.

  20. Human computer interaction using hand gestures

    CERN Document Server

    Premaratne, Prashan

    2014-01-01

    Human computer interaction (HCI) plays a vital role in bridging the 'Digital Divide', bringing people closer to consumer electronics control in the 'lounge'. Keyboards and mouse or remotes do alienate old and new generations alike from control interfaces. Hand Gesture Recognition systems bring hope of connecting people with machines in a natural way. This will lead to consumers being able to use their hands naturally to communicate with any electronic equipment in their 'lounge.' This monograph will include the state of the art hand gesture recognition approaches and how they evolved from their inception. The author would also detail his research in this area for the past 8 years and how the future might turn out to be using HCI. This monograph will serve as a valuable guide for researchers (who would endeavour into) in the world of HCI.

  1. Dosimetry of hands and human factor

    International Nuclear Information System (INIS)

    Harr, R.

    2008-12-01

    The human factor in facilities where open radioactive sources are managed it can be controlled through the use of the ring dosimetry, however, that these devices only provide qualitative information that is not extrapolated to legislative limits. lt is present the case analysis of hands dosimetry of female person with responsibility for professional standards and a very high profile with ratings that allow her to have a high level of knowledge of the basic standards, and because with an attitude and a culture rooted of radiation protection, among other qualities. Their records reveal a trend in which monthly doses are below the 7 mSv, and only occasionally are between 7 and 12 mSv per month and hand. The other case correspond to a technician, trained in radiological techniques, also with a high profile, with two courses for occupationally exposed personnel more than 10 annual retraining, and work experience of over 10 years as occupationally exposed personnel, in which knowledge of standards and because of the entrenched culture of radiation protection and their interest degree in the care of their exposure is still in a phase half, in this case also shows a trend in the monthly dose where found registers between 7 and 11 mSv per month and hand. The third case is of a second technician with less experience and most basic knowledge, his dose register not show a real trend, sometimes be found reads of irregular values as if the dosimeter is not used and some other times as if misused by exposing to purpose (was observed at least one reading above the monthly 30 mSv). By way of conclusion, it is noted that the hands dosimetry is a useful tool to monitor transactions through the data compilation susceptible to analysis with variations which can be placed in the context of the human factor. (Author)

  2. Color-Removal by Microorganisms Isolated from Human Hands

    Directory of Open Access Journals (Sweden)

    Tsukasa Ito

    2013-08-01

    Full Text Available Microorganisms are essential for human life. Microorganisms decompose the carbon compounds in dead animals and plants and convert them into carbon dioxide. Intestinal bacteria assist in food digestion. Some vitamins are produced by bacteria that live in the intestines. Sewage and industrial wastewater are treated by activated sludge composed of microbial communities. All of these are due to the ability of microbes to produce many enzymes that can degrade chemicals. How do teachers make students understand that microorganisms are always associated with humans, and that microorganisms have the ability to degrade chemicals? The presence of microorganisms on humans can be shown by incubating agar plates after they are touched by the hands of students. The ability of microorganisms to degrade chemicals can be shown by an analytical measurement of the degradation of chemicals. When the chemicals are dyes (colorants in water, microbial activity on degradation of dyes can be demonstrated by observing a decreasing degree of color as a result of the enzymatic activity (e.g., azoreductase. Dyes are widely used in the textile, food, and cosmetic industries. They are generally resistant to conventional biological wastewater treatment systems such as the activated sludge process (4. The discharge of wastewater containing dye pollutes surface water. The ability of microorganisms to decolorize and degrade dyes has been widely investigated to use for bioremediation purposes (5. The goal of this tip is to understand the presence of bacteria on human skin and the ability of bacteria to degrade colorant chemicals (decolorization. In this tip, students first cultivate and isolate bacteria on their hands, and then examine potential decolorization activity of each bacterium by observing the degree of color of the liquid in tubes in which bacteria isolated from students’ hands were inoculated. Decolorization activity of bacterial isolates from human skin has been

  3. Simulation of irradiation X in human hand

    International Nuclear Information System (INIS)

    Amaya Falcon, F.

    2001-01-01

    Use of the Monte Carlo code MCNP to simulate a human hand irradiation with radiation X of radio diagnosis energy, in order to find the best range of energy to obtain a radiography with the smallest dose and the biggest contrast [es

  4. Real-Time Hand Position Sensing Technology Based on Human Body Electrostatics

    Directory of Open Access Journals (Sweden)

    Kai Tang

    2018-05-01

    Full Text Available Non-contact human-computer interactions (HCI based on hand gestures have been widely investigated. Here, we present a novel method to locate the real-time position of the hand using the electrostatics of the human body. This method has many advantages, including a delay of less than one millisecond, low cost, and does not require a camera or wearable devices. A formula is first created to sense array signals with five spherical electrodes. Next, a solving algorithm for the real-time measured hand position is introduced and solving equations for three-dimensional coordinates of hand position are obtained. A non-contact real-time hand position sensing system was established to perform verification experiments, and the principle error of the algorithm and the systematic noise were also analyzed. The results show that this novel technology can determine the dynamic parameters of hand movements with good robustness to meet the requirements of complicated HCI.

  5. Measuring empathy for human and robot hand pain using electroencephalography.

    Science.gov (United States)

    Suzuki, Yutaka; Galli, Lisa; Ikeda, Ayaka; Itakura, Shoji; Kitazaki, Michiteru

    2015-11-03

    This study provides the first physiological evidence of humans' ability to empathize with robot pain and highlights the difference in empathy for humans and robots. We performed electroencephalography in 15 healthy adults who observed either human- or robot-hand pictures in painful or non-painful situations such as a finger cut by a knife. We found that the descending phase of the P3 component was larger for the painful stimuli than the non-painful stimuli, regardless of whether the hand belonged to a human or robot. In contrast, the ascending phase of the P3 component at the frontal-central electrodes was increased by painful human stimuli but not painful robot stimuli, though the interaction of ANOVA was not significant, but marginal. These results suggest that we empathize with humanoid robots in late top-down processing similarly to human others. However, the beginning of the top-down process of empathy is weaker for robots than for humans.

  6. Quantity of ethanol absorption after excessive hand disinfection using three commercially available hand rubs is minimal and below toxic levels for humans

    Directory of Open Access Journals (Sweden)

    Toma Cyril D

    2007-10-01

    Full Text Available Abstract Background Despite the increasing promotion of alcohol-based hand rubs and the worldwide use of ethanol-based hand rubs in hospitals only few studies have specifically addressed the issue of ethanol absorption when repeatedly applied to human skin. The aim of this study was to assess if ethanol absorption occurs during hygienic and surgical hand disinfection using three different alcohol-based hand-rubs, and to quantify absorption levels in humans. Methods Twelve volunteers applied three hand-rubs containing 95% (hand-rub A, 85% (hand-rub B and 55% ethanol (hand-rub C; all w/w. For hygienic hand disinfection, 4 mL were applied 20 times for 30 s, with 1 minute break between applications. For surgical hand disinfection, 20 mL of each hand rub was applied to hands and arms up to the level of the elbow 10 times for 3 minutes, with a break of 5 minutes between applications. Blood concentrations of ethanol and acetaldehyde were determined immediately prior and up to 90 minutes after application using head space gas chromatography. Results The median of absorbed ethanol after hygienic hand disinfection was 1365 mg (A, 630 mg (B, and 358 mg (C. The proportion of absorbed ethanol was 2.3% (A, 1.1% (B, and 0.9% (C. After surgical hand disinfection, the median of absorbed ethanol was 1067 mg (A, 1542 mg (B, and 477 mg (C. The proportion of absorbed ethanol was 0.7% (A, 1.1% (B, and 0.5% (C. The highest median acetaldehyde concentration after 20 hygienic hand disinfections was 0.57 mg/L (hand-rub C, after 30 min, after 10 surgical hand disinfections 3.99 mg/L (hand-rub A, after 20 minutes. Conclusion The overall dermal and pulmonary absorption of ethanol was below toxic levels in humans and allows the conclusion that the use of the evaluated ethanol-based hand-rubs is safe.

  7. EthoHand: A dexterous robotic hand with ball-joint thumb enables complex in-hand object manipulation

    OpenAIRE

    Konnaris, C; Gavriel, C; Thomik, AAC; Aldo Faisal, A

    2016-01-01

    Our dexterous hand is a fundmanetal human feature that distinguishes us from other animals by enabling us to go beyond grasping to support sophisticated in-hand object manipulation. Our aim was the design of a dexterous anthropomorphic robotic hand that matches the human hand's 24 degrees of freedom, under-actuated by seven motors. With the ability to replicate human hand movements in a naturalistic manner including in-hand object manipulation. Therefore, we focused on the development of a no...

  8. The Human Octopus: controlling supernumerary hands with the help of virtual reality

    OpenAIRE

    Aru, Jaan; Vasser, Madis; Zafra, Raul; Kulu, Sander

    2016-01-01

    We investigated the "human octopus" phenomenon where subjects controlled virtual supernumerary hands through hand tracking technology and virtual reality. Four experiments were developed to study how subjects (n=10) operate with different number and behaviour of supernumerary hands. The behaviours involved inserting movement delays to the virtual hands and adjusting their movement scale or position. It was found that having more hands to operate with does not necessarily mean higher success r...

  9. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    Science.gov (United States)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  10. Human-like Compliance for Dexterous Robot Hands

    Science.gov (United States)

    Jau, Bruno M.

    1995-01-01

    This paper describes the Active Electromechanical Compliance (AEC) system that was developed for the Jau-JPL anthropomorphic robot. The AEC system imitates the functionality of the human muscle's secondary function, which is to control the joint's stiffness: AEC is implemented through servo controlling the joint drive train's stiffness. The control strategy, controlling compliant joints in teleoperation, is described. It enables automatic hybrid position and force control through utilizing sensory feedback from joint and compliance sensors. This compliant control strategy is adaptable for autonomous robot control as well. Active compliance enables dual arm manipulations, human-like soft grasping by the robot hand, and opens the way to many new robotics applications.

  11. Variable Thumb Moment Arm Modeling and Thumb-Tip Force Production of a Human-Like Robotic Hand.

    Science.gov (United States)

    Niehues, Taylor D; Deshpande, Ashish D

    2017-10-01

    The anatomically correct testbed (ACT) hand mechanically simulates the musculoskeletal structure of the fingers and thumb of the human hand. In this work, we analyze the muscle moment arms (MAs) and thumb-tip force vectors in the ACT thumb in order to compare the ACT thumb's mechanical structure to the human thumb. Motion data are used to determine joint angle-dependent MA models, and thumb-tip three-dimensional (3D) force vectors are experimentally analyzed when forces are applied to individual muscles. Results are presented for both a nominal ACT thumb model designed to match human MAs and an adjusted model that more closely replicates human-like thumb-tip forces. The results confirm that the ACT thumb is capable of faithfully representing human musculoskeletal structure and muscle functionality. Using the ACT hand as a physical simulation platform allows us to gain a better understanding of the underlying biomechanical and neuromuscular properties of the human hand to ultimately inform the design and control of robotic and prosthetic hands.

  12. Simulation of X-ray irradiation on human hand

    International Nuclear Information System (INIS)

    Amaya, Fabiola; Montoya, Modesto

    2001-01-01

    Using the Monte Carlo code MCNP we simulate a human hand X-rays irradiation with radiodiagnostic energies to find the better range energy to make radiographs with the lowest dose and an optimal contrast. We calculate bone doses by considering a soft tissue - water - and calcium bone hand, which is irradiated with a million of X-rays photons from a punctual source. These photons are directed inside a conic angle on the hand. Afterwards, we simulate elements which normally compose bones (C, H, O, N, Mg, P, Ca, and S). We estimate bone dose considering: a) bone material (water, calcium and bone tissue); b) bone thickness (0.01; 0.1; 0.5; 1.0; 1.5 and 3.0 cm); and c) source-hand distance (30, 50, 70 and 90 cm). We calculate photon transmission percent through soft tissue and bone tissue and the statistics from the number of photons that reach the radiographic film after passing through soft tissue or bone tissue for our geometric configuration. We found that we can obtain a good image contrast by using X-rays with energies in the range of 20 to 40 keV. (author)

  13. Human left ventral premotor cortex mediates matching of hand posture to object use.

    Directory of Open Access Journals (Sweden)

    Guy Vingerhoets

    Full Text Available Visuomotor transformations for grasping have been associated with a fronto-parietal network in the monkey brain. The human homologue of the parietal monkey region (AIP has been identified as the anterior part of the intraparietal sulcus (aIPS, whereas the putative human equivalent of the monkey frontal region (F5 is located in the ventral part of the premotor cortex (vPMC. Results from animal studies suggest that monkey F5 is involved in the selection of appropriate hand postures relative to the constraints of the task. In humans, the functional roles of aIPS and vPMC appear to be more complex and the relative contribution of each region to grasp selection remains uncertain. The present study aimed to identify modulation in brain areas sensitive to the difficulty level of tool object - hand posture matching. Seventeen healthy right handed participants underwent fMRI while observing pictures of familiar tool objects followed by pictures of hand postures. The task was to decide whether the hand posture matched the functional use of the previously shown object. Conditions were manipulated for level of difficulty. Compared to a picture matching control task, the tool object - hand posture matching conditions conjointly showed increased modulation in several left hemispheric regions of the superior and inferior parietal lobules (including aIPS, the middle occipital gyrus, and the inferior temporal gyrus. Comparison of hard versus easy conditions selectively modulated the left inferior frontal gyrus with peak activity located in its opercular part (Brodmann area (BA 44. We suggest that in the human brain, vPMC/BA44 is involved in the matching of hand posture configurations in accordance with visual and functional demands.

  14. Robotic hand project

    OpenAIRE

    Karaçizmeli, Cengiz; Çakır, Gökçe; Tükel, Dilek

    2014-01-01

    In this work, the mechatronic based robotic hand is controlled by the position data taken from the glove which has flex sensors mounted to capture finger bending of the human hand. The angular movement of human hand’s fingers are perceived and processed by a microcontroller, and the robotic hand is controlled by actuating servo motors. It has seen that robotic hand can simulate the movement of the human hand that put on the glove, during tests have done. This robotic hand can be used not only...

  15. Kinetics of adenylate metabolism in human and rat myocardium

    OpenAIRE

    Tavenier, M.; Skladanowski, A.C.; Abreu, R.A. de; Jong, J.W. de

    1995-01-01

    textabstractPathways producing and converting adenosine have hardly been investigated in human heart, contrasting work in other species. We compared the kinetics of enzymes associated with purine degradation and salvage in human and rat heart cytoplasm assaying for adenosine deaminase, nucleoside phosphorylase, xanthine oxidoreductase, AMP deaminase, AMP- and IMP-specific 5′-nucleotidases, adenosine kinase and hypoxanthine guanine phosphoribosyltransferase (HGPRT). Xanthine oxidoreductase was...

  16. Kinetic constrained optimization of the golf swing hub path.

    Science.gov (United States)

    Nesbit, Steven M; McGinnis, Ryan S

    2014-12-01

    This study details an optimization of the golf swing, where the hand path and club angular trajectories are manipulated. The optimization goal was to maximize club head velocity at impact within the interaction kinetic limitations (force, torque, work, and power) of the golfer as determined through the analysis of a typical swing using a two-dimensional dynamic model. The study was applied to four subjects with diverse swing capabilities and styles. It was determined that it is possible for all subjects to increase their club head velocity at impact within their respective kinetic limitations through combined modifications to their respective hand path and club angular trajectories. The manner of the modifications, the degree of velocity improvement, the amount of kinetic reduction, and the associated kinetic limitation quantities were subject dependent. By artificially minimizing selected kinetic inputs within the optimization algorithm, it was possible to identify swing trajectory characteristics that indicated relative kinetic weaknesses of a subject. Practical implications are offered based upon the findings of the study. Key PointsThe hand path trajectory is an important characteristic of the golf swing and greatly affects club head velocity and golfer/club energy transfer.It is possible to increase the energy transfer from the golfer to the club by modifying the hand path and swing trajectories without increasing the kinetic output demands on the golfer.It is possible to identify relative kinetic output strengths and weakness of a golfer through assessment of the hand path and swing trajectories.Increasing any one of the kinetic outputs of the golfer can potentially increase the club head velocity at impact.The hand path trajectory has important influences over the club swing trajectory.

  17. Single treatment with ethanol hand rub is ineffective against human rhinovirus--hand washing with soap and water removes the virus efficiently.

    Science.gov (United States)

    Savolainen-Kopra, Carita; Korpela, Terttu; Simonen-Tikka, Marja-Leena; Amiryousefi, Ali; Ziegler, Thedi; Roivainen, Merja; Hovi, Tapani

    2012-03-01

    Ethanol-containing hand rubs are used frequently as a substitute for hand washing with water and soap. However, not all viruses are inactivated by a short term rubbing with alcohol. The capacity of a single round of instructed and controlled hand cleaning with water and soap or ethanol-containing hand rub, respectively, was tested for removal of human rhinovirus administered onto the skin of healthy volunteers on the back of the hands. Hand washing with soap and water appeared to be much more efficient for removing rhinoviruses from skin than rubbing hands with an ethanol-containing disinfectant. After washing with soap and water the virus was detected in 3/9 (33.3%) test persons from the left hand and 1/9 (11.1%) cases from the right hand, whereas the virus was detected invariably by real-time RT-PCR from both hands after cleaning with alcohol hand rub (P-value soap can clean efficiently hands contaminated with the virus responsible for an extensive share of common cold episodes. Copyright © 2012 Wiley Periodicals, Inc.

  18. Understanding Human Hand Gestures for Learning Robot Pick-and-Place Tasks

    Directory of Open Access Journals (Sweden)

    Hsien-I Lin

    2015-05-01

    Full Text Available Programming robots by human demonstration is an intuitive approach, especially by gestures. Because robot pick-and-place tasks are widely used in industrial factories, this paper proposes a framework to learn robot pick-and-place tasks by understanding human hand gestures. The proposed framework is composed of the module of gesture recognition and the module of robot behaviour control. For the module of gesture recognition, transport empty (TE, transport loaded (TL, grasp (G, and release (RL from Gilbreth's therbligs are the hand gestures to be recognized. A convolution neural network (CNN is adopted to recognize these gestures from a camera image. To achieve the robust performance, the skin model by a Gaussian mixture model (GMM is used to filter out non-skin colours of an image, and the calibration of position and orientation is applied to obtain the neutral hand pose before the training and testing of the CNN. For the module of robot behaviour control, the corresponding robot motion primitives to TE, TL, G, and RL, respectively, are implemented in the robot. To manage the primitives in the robot system, a behaviour-based programming platform based on the Extensible Agent Behavior Specification Language (XABSL is adopted. Because the XABSL provides the flexibility and re-usability of the robot primitives, the hand motion sequence from the module of gesture recognition can be easily used in the XABSL programming platform to implement the robot pick-and-place tasks. The experimental evaluation of seven subjects performing seven hand gestures showed that the average recognition rate was 95.96%. Moreover, by the XABSL programming platform, the experiment showed the cube-stacking task was easily programmed by human demonstration.

  19. Growth kinetics of four human breast carcinomas grown in nude mice

    DEFF Research Database (Denmark)

    Spang-Thomsen, M; Rygaard, K; Hansen, L

    1989-01-01

    with cell generation times of 42 to 60 hours. The three receptor-positive tumors had slower growth rate, larger tumor volume doubling time, and smaller growth fraction and labelling index than the receptor-negative tumor. However, no single proliferation parameter was sufficient to characterize the growth......The immune-deficient nude mouse with human tumor xenografts is an appropriate model system for performing detailed growth kinetic examinations. In the present study one estrogen and progesterone receptor-negative (T60) and three receptor-positive (Br-10, MCF-7, T61) human breast cancer xenografts...... in nude mice were investigated. The proliferative tumor characteristics were examined by growth curves, thymidine labelling technique, and flow cytometric DNA analysis performed on fine-needle aspirations. The results showed that the tumors had growth kinetics comparable to other human tumor types...

  20. Human-Human Interaction Forces and Interlimb Coordination During Side-by-Side Walking With Hand Contact.

    Science.gov (United States)

    Sylos-Labini, Francesca; d'Avella, Andrea; Lacquaniti, Francesco; Ivanenko, Yury

    2018-01-01

    Handholding can naturally occur between two walkers. When people walk side-by-side, either with or without hand contact, they often synchronize their steps. However, despite the importance of haptic interaction in general and the natural use of hand contact between humans during walking, few studies have investigated forces arising from physical interactions. Eight pairs of adult subjects participated in this study. They walked on side-by-side treadmills at 4 km/h independently and with hand contact. Only hand contact-related sensory information was available for unintentional synchronization, while visual and auditory communication was obstructed. Subjects walked at their natural cadences or following a metronome. Limb kinematics, hand contact 3D interaction forces and EMG activity of 12 upper limb muscles were recorded. Overall, unintentional step frequency locking was observed during about 40% of time in 88% of pairs walking with hand contact. On average, the amplitude of contact arm oscillations decreased while the contralateral (free) arm oscillated in the same way as during normal walking. Interestingly, EMG activity of the shoulder muscles of the contact arm did not decrease, and their synergistic pattern remained similar. The amplitude of interaction forces and of trunk oscillations was similar for synchronized and non-synchronized steps, though the synchronized steps were characterized by significantly more regular orientations of interaction forces. Our results further support the notion that gait synchronization during natural walking is common, and that it may occur through interaction forces. Conservation of the proximal muscle activity of the contact (not oscillating) arm is consistent with neural coupling between cervical and lumbosacral pattern generation circuitries ("quadrupedal" arm-leg coordination) during human gait. Overall, the findings suggest that individuals might integrate force interaction cues to communicate and coordinate steps during

  1. Human-Human Interaction Forces and Interlimb Coordination During Side-by-Side Walking With Hand Contact

    Directory of Open Access Journals (Sweden)

    Francesca Sylos-Labini

    2018-03-01

    Full Text Available Handholding can naturally occur between two walkers. When people walk side-by-side, either with or without hand contact, they often synchronize their steps. However, despite the importance of haptic interaction in general and the natural use of hand contact between humans during walking, few studies have investigated forces arising from physical interactions. Eight pairs of adult subjects participated in this study. They walked on side-by-side treadmills at 4 km/h independently and with hand contact. Only hand contact-related sensory information was available for unintentional synchronization, while visual and auditory communication was obstructed. Subjects walked at their natural cadences or following a metronome. Limb kinematics, hand contact 3D interaction forces and EMG activity of 12 upper limb muscles were recorded. Overall, unintentional step frequency locking was observed during about 40% of time in 88% of pairs walking with hand contact. On average, the amplitude of contact arm oscillations decreased while the contralateral (free arm oscillated in the same way as during normal walking. Interestingly, EMG activity of the shoulder muscles of the contact arm did not decrease, and their synergistic pattern remained similar. The amplitude of interaction forces and of trunk oscillations was similar for synchronized and non-synchronized steps, though the synchronized steps were characterized by significantly more regular orientations of interaction forces. Our results further support the notion that gait synchronization during natural walking is common, and that it may occur through interaction forces. Conservation of the proximal muscle activity of the contact (not oscillating arm is consistent with neural coupling between cervical and lumbosacral pattern generation circuitries (“quadrupedal” arm-leg coordination during human gait. Overall, the findings suggest that individuals might integrate force interaction cues to communicate and

  2. Effect of gender and hand laterality on pain processing in human neonates.

    Science.gov (United States)

    Ozawa, Mio; Kanda, Katsuya; Hirata, Michio; Kusakawa, Isao; Suzuki, Chieko

    2011-01-01

    Previous studies in adults have reported that handedness and gender can affect pain perception. However, it is currently unclear when these differences emerge in human development. Therefore, we examined prefrontal responses to pain stimulation among newborns during their first acute pain experience after birth. Forty newborns at 4-6 days postnatal age were observed during clinically required blood sampling while prefrontal activation was measured with near infrared spectroscopy. Blood sampling in this study was the first experience of a procedure involving skin breaking for these infants. We divided subjects into a right-hand stimulation group (n=21) and a left-hand stimulation group (n=19), depending on whether blood was sampled from the right or the left hand. A three-way analysis of variance (ANOVA) was conducted to examine the effects of several variables on the magnitude of the oxy-Hb value in response to pain stimulus, including stimulus side (right hand or left hand), gender (male or female), recording side (right prefrontal area or left prefrontal area) and interactions between these variables. The data revealed a significant effect of stimulus side (F (1, 72)=9.892, P=0.002), showing that the right-hand stimulation induced a greater prefrontal activation than the left-hand stimulation. No significant gender difference or interactions were found. Our findings suggest that hand laterality affects pain perception even in neonates. However, gender differences in pain perception did not appear to occur during the neonatal period. Further investigations using brain-imaging techniques are required to identify laterality- or gender-related differences in pain processing in humans. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Selection of suitable hand gestures for reliable myoelectric human computer interface.

    Science.gov (United States)

    Castro, Maria Claudia F; Arjunan, Sridhar P; Kumar, Dinesh K

    2015-04-09

    Myoelectric controlled prosthetic hand requires machine based identification of hand gestures using surface electromyogram (sEMG) recorded from the forearm muscles. This study has observed that a sub-set of the hand gestures have to be selected for an accurate automated hand gesture recognition, and reports a method to select these gestures to maximize the sensitivity and specificity. Experiments were conducted where sEMG was recorded from the muscles of the forearm while subjects performed hand gestures and then was classified off-line. The performances of ten gestures were ranked using the proposed Positive-Negative Performance Measurement Index (PNM), generated by a series of confusion matrices. When using all the ten gestures, the sensitivity and specificity was 80.0% and 97.8%. After ranking the gestures using the PNM, six gestures were selected and these gave sensitivity and specificity greater than 95% (96.5% and 99.3%); Hand open, Hand close, Little finger flexion, Ring finger flexion, Middle finger flexion and Thumb flexion. This work has shown that reliable myoelectric based human computer interface systems require careful selection of the gestures that have to be recognized and without such selection, the reliability is poor.

  4. A synergy-based hand control is encoded in human motor cortical areas

    Science.gov (United States)

    Leo, Andrea; Handjaras, Giacomo; Bianchi, Matteo; Marino, Hamal; Gabiccini, Marco; Guidi, Andrea; Scilingo, Enzo Pasquale; Pietrini, Pietro; Bicchi, Antonio; Santello, Marco; Ricciardi, Emiliano

    2016-01-01

    How the human brain controls hand movements to carry out different tasks is still debated. The concept of synergy has been proposed to indicate functional modules that may simplify the control of hand postures by simultaneously recruiting sets of muscles and joints. However, whether and to what extent synergic hand postures are encoded as such at a cortical level remains unknown. Here, we combined kinematic, electromyography, and brain activity measures obtained by functional magnetic resonance imaging while subjects performed a variety of movements towards virtual objects. Hand postural information, encoded through kinematic synergies, were represented in cortical areas devoted to hand motor control and successfully discriminated individual grasping movements, significantly outperforming alternative somatotopic or muscle-based models. Importantly, hand postural synergies were predicted by neural activation patterns within primary motor cortex. These findings support a novel cortical organization for hand movement control and open potential applications for brain-computer interfaces and neuroprostheses. DOI: http://dx.doi.org/10.7554/eLife.13420.001 PMID:26880543

  5. Comparison of human and electronic observation for the measurement of compliance with hand hygiene.

    Science.gov (United States)

    Filho, Miguel Almeida O; Marra, Alexandre R; Magnus, Thyago Pereira; Rodrigues, Rodrigo Dias; Prado, Marcelo; de Souza Santini, Tales Roberto; da Silva Victor, Elivane; Ishibe, Eder Issao; Pavão Dos Santos, Oscar Fernando; Edmond, Michael B

    2014-11-01

    Monitoring of hand hygiene is an important part of the improvement of hospital quality indicators. This study was prospectively performed over a 14-week (electronic observer) period from December 3, 2013-March 9, 2014, to evaluate hand hygiene compliance in an adult step-down unit. We compared electronic handwash counters with the application of radiofrequency identification (RFID - ZigBee; i-Healthsys, São Carlos, Brazil) (electronic observer), which counts each activation of the alcohol gel dispenser to direct observation (human observer) using the iScrub application. For the overall time period of simultaneous electronic and human observation, we found that the electronic observer identified 414 hand hygiene episodes, whereas the human observers identified 448 episodes. Therefore, we found 92% (95% confidence interval [CI], 90%-95%) overall concordance (414/448), with an intraclass correlation coefficient of .87 (95% CI, 0.77-0.92). Our RFID (ZigBee) system showed good accuracy (92%) and is a useful method to monitor hand hygiene compliance. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Classification of Hand Grasp Kinetics and Types Using Movement-Related Cortical Potentials and EEG Rhythms

    Directory of Open Access Journals (Sweden)

    Mads Jochumsen

    2017-01-01

    Full Text Available Detection of single-trial movement intentions from EEG is paramount for brain-computer interfacing in neurorehabilitation. These movement intentions contain task-related information and if this is decoded, the neurorehabilitation could potentially be optimized. The aim of this study was to classify single-trial movement intentions associated with two levels of force and speed and three different grasp types using EEG rhythms and components of the movement-related cortical potential (MRCP as features. The feature importance was used to estimate encoding of discriminative information. Two data sets were used. 29 healthy subjects executed and imagined different hand movements, while EEG was recorded over the contralateral sensorimotor cortex. The following features were extracted: delta, theta, mu/alpha, beta, and gamma rhythms, readiness potential, negative slope, and motor potential of the MRCP. Sequential forward selection was performed, and classification was performed using linear discriminant analysis and support vector machines. Limited classification accuracies were obtained from the EEG rhythms and MRCP-components: 0.48±0.05 (grasp types, 0.41±0.07 (kinetic profiles, motor execution, and 0.39±0.08 (kinetic profiles, motor imagination. Delta activity contributed the most but all features provided discriminative information. These findings suggest that information from the entire EEG spectrum is needed to discriminate between task-related parameters from single-trial movement intentions.

  7. Norepinephrine metabolism in humans. Kinetic analysis and model

    International Nuclear Information System (INIS)

    Linares, O.A.; Jacquez, J.A.; Zech, L.A.; Smith, M.J.; Sanfield, J.A.; Morrow, L.A.; Rosen, S.G.; Halter, J.B.

    1987-01-01

    The present study was undertaken to quantify more precisely and to begin to address the problem of heterogeneity of the kinetics of distribution and metabolism of norepinephrine (NE) in humans, by using compartmental analysis. Steady-state NE specific activity in arterialized plasma during [ 3 H]NE infusion and postinfusion plasma disappearance of [ 3 H]NE were measured in eight healthy subjects in the supine and upright positions. Two exponentials were clearly identified in the plasma [ 3 H]NE disappearance curves of each subject studied in the supine (r = 0.94-1.00, all P less than 0.01) and upright (r = 0.90-0.98, all P less than 0.01) positions. A two-compartment model was the minimal model necessary to simultaneously describe the kinetics of NE in the supine and upright positions. The NE input rate into the extravascular compartment 2, estimated with the minimal model, increased with upright posture (1.87 +/- 0.08 vs. 3.25 +/- 0.2 micrograms/min per m2, P less than 0.001). Upright posture was associated with a fall in the volume of distribution of NE in compartment 1 (7.5 +/- 0.6 vs. 4.7 +/- 0.3 liters, P less than 0.001), and as a result of that, there was a fall in the metabolic clearance rate of NE from compartment 1 (1.80 +/- 0.11 vs. 1.21 +/- 0.08 liters/min per m2, P less than 0.001). We conclude that a two-compartment model is the minimal model that can accurately describe the kinetics of distribution and metabolism of NE in humans

  8. Quantifying human vitamin kinetics using AMS

    Energy Technology Data Exchange (ETDEWEB)

    Hillegonds, D; Dueker, S; Ognibene, T; Buchholz, B; Lin, Y; Vogel, J; Clifford, A

    2004-02-19

    Tracing vitamin kinetics at physiologic concentrations has been hampered by a lack of quantitative sensitivity for chemically equivalent tracers that could be used safely in healthy people. Instead, elderly or ill volunteers were sought for studies involving pharmacologic doses with radioisotopic labels. These studies fail to be relevant in two ways: vitamins are inherently micronutrients, whose biochemical paths are saturated and distorted by pharmacological doses; and while vitamins remain important for health in the elderly or ill, their greatest effects may be in preventing slow and cumulative diseases by proper consumption throughout youth and adulthood. Neither the target dose nor the target population are available for nutrient metabolic studies through decay counting of radioisotopes at high levels. Stable isotopic labels are quantified by isotope ratio mass spectrometry at levels that trace physiologic vitamin doses, but the natural background of stable isotopes severely limits the time span over which the tracer is distinguishable. Indeed, study periods seldom ranged over a single biological mean life of the labeled nutrients, failing to provide data on the important final elimination phase of the compound. Kinetic data for the absorption phase is similarly rare in micronutrient research because the phase is rapid, requiring many consecutive plasma samples for accurate representation. However, repeated blood samples of sufficient volume for precise stable or radio-isotope quantitations consume an indefensible amount of the volunteer's blood over a short period. Thus, vitamin pharmacokinetics in humans has often relied on compartmental modeling based upon assumptions and tested only for the short period of maximal blood circulation, a period that poorly reflects absorption or final elimination kinetics except for the most simple models.

  9. Hand Gesture Modeling and Recognition for Human and Robot Interactive Assembly Using Hidden Markov Models

    Directory of Open Access Journals (Sweden)

    Fei Chen

    2015-04-01

    Full Text Available Gesture recognition is essential for human and robot collaboration. Within an industrial hybrid assembly cell, the performance of such a system significantly affects the safety of human workers. This work presents an approach to recognizing hand gestures accurately during an assembly task while in collaboration with a robot co-worker. We have designed and developed a sensor system for measuring natural human-robot interactions. The position and rotation information of a human worker's hands and fingertips are tracked in 3D space while completing a task. A modified chain-code method is proposed to describe the motion trajectory of the measured hands and fingertips. The Hidden Markov Model (HMM method is adopted to recognize patterns via data streams and identify workers' gesture patterns and assembly intentions. The effectiveness of the proposed system is verified by experimental results. The outcome demonstrates that the proposed system is able to automatically segment the data streams and recognize the gesture patterns thus represented with a reasonable accuracy ratio.

  10. RGBD Video Based Human Hand Trajectory Tracking and Gesture Recognition System

    Directory of Open Access Journals (Sweden)

    Weihua Liu

    2015-01-01

    Full Text Available The task of human hand trajectory tracking and gesture trajectory recognition based on synchronized color and depth video is considered. Toward this end, in the facet of hand tracking, a joint observation model with the hand cues of skin saliency, motion and depth is integrated into particle filter in order to move particles to local peak in the likelihood. The proposed hand tracking method, namely, salient skin, motion, and depth based particle filter (SSMD-PF, is capable of improving the tracking accuracy considerably, in the context of the signer performing the gesture toward the camera device and in front of moving, cluttered backgrounds. In the facet of gesture recognition, a shape-order context descriptor on the basis of shape context is introduced, which can describe the gesture in spatiotemporal domain. The efficient shape-order context descriptor can reveal the shape relationship and embed gesture sequence order information into descriptor. Moreover, the shape-order context leads to a robust score for gesture invariant. Our approach is complemented with experimental results on the settings of the challenging hand-signed digits datasets and American sign language dataset, which corroborate the performance of the novel techniques.

  11. Optical coherence tomography, In vivo human hand explorer, optical coherence microscope

    CSIR Research Space (South Africa)

    Jonathan, E

    2008-07-01

    Full Text Available The hand palm is an important human body part primarily for physical manipulation of the environment. For example, palmar hyperhidriotics report a low quality of life due to excessive palmar sweating disrupting normal palm use. As a body part...

  12. Tactile mouse generating velvet hand illusion on human palm

    Directory of Open Access Journals (Sweden)

    Nadar Rajaei

    2016-09-01

    Full Text Available To enhance virtual reality (VR generated by tactile displays, we have focused on a novel tactile illusion, called the Velvet Hand Illusion (VHI. In VHI, moving two parallel wires back and forth between the two hands leads humans to perceive a velvet-like surface between their hands. In earlier studies, we revealed that the intensity of VHI could be controlled by a ratio (r/D, where r and D are the wire stroke and wire distance, respectively. According to these findings, we investigate in this study whether a common tactile display is able to produce VHI, and whether the ratio can also control VHI intensity. We prepare a dot-matrix display as a tactile display in which moving one line of the display’s pins is considered as a wire pattern. We investigate the VHI intensity with regard to changing the stroke r and the line distance D using paired comparison. Experimental results show that the VHI intensity is increased or decreased by changing r and D. We conclude that VHI can be created by the tactile display, and the intensity of VHI is controlled by changing the ratio of r/D.

  13. Human kinetics of orally and intravenously administered low-dose 1,2-(13)C-dichloroacetate.

    Science.gov (United States)

    Jia, Minghong; Coats, Bonnie; Chadha, Monisha; Frentzen, Barbara; Perez-Rodriguez, Javier; Chadik, Paul A; Yost, Richard A; Henderson, George N; Stacpoole, Peter W

    2006-12-01

    Dichloroacetate (DCA) is a putative environmental hazard, owing to its ubiquitous presence in the biosphere and its association with animal and human toxicity. We sought to determine the kinetics of environmentally relevant concentrations of 1,2-(13)C-DCA administered to healthy adults. Subjects received an oral or intravenous dose of 2.5 microg/kg of 1,2-(13)C-DCA. Plasma and urine concentrations of 1,2-(13)C-DCA were measured by a modified gas chromatography-tandem mass spectrometry method. 1,2-(13)C-DCA kinetics was determined by modeling using WinNonlin 4.1 software. Plasma concentrations of 1,2-(13)C-DCA peaked 10 minutes and 30 minutes after intravenous or oral administration, respectively. Plasma kinetic parameters varied as a function of dose and duration. Very little unchanged 1,2-(13)C-DCA was excreted in urine. Trace amounts of DCA alter its own kinetics after short-term exposure. These findings have important implications for interpreting the impact of this xenobiotic on human health.

  14. Efficacy of soap and water and alcohol-based hand-rub preparations against live H1N1 influenza virus on the hands of human volunteers.

    Science.gov (United States)

    Grayson, M Lindsay; Melvani, Sharmila; Druce, Julian; Barr, Ian G; Ballard, Susan A; Johnson, Paul D R; Mastorakos, Tasoula; Birch, Christopher

    2009-02-01

    Although pandemic and avian influenza are known to be transmitted via human hands, there are minimal data regarding the effectiveness of routine hand hygiene (HH) protocols against pandemic and avian influenza. Twenty vaccinated, antibody-positive health care workers had their hands contaminated with 1 mL of 10(7) tissue culture infectious dose (TCID)(50)/0.1 mL live human influenza A virus (H1N1; A/New Caledonia/20/99) before undertaking 1 of 5 HH protocols (no HH [control], soap and water hand washing [SW], or use of 1 of 3 alcohol-based hand rubs [61.5% ethanol gel, 70% ethanol plus 0.5% chlorhexidine solution, or 70% isopropanol plus 0.5% chlorhexidine solution]). H1N1 concentrations were assessed before and after each intervention by viral culture and real-time reverse-transcriptase polymerase chain reaction (PCR). The natural viability of H1N1 on hands for >60 min without HH was also assessed. There was an immediate reduction in culture-detectable and PCR-detectable H1N1 after brief cutaneous air drying--14 of 20 health care workers had H1N1 detected by means of culture (mean reduction, 10(3-4) TCID(50)/0.1 mL), whereas 6 of 20 had no viable H1N1 recovered; all 20 health care workers had similar changes in PCR test results. Marked antiviral efficacy was noted for all 4 HH protocols, on the basis of culture results (14 of 14 had no culturable H1N1; (P< .002) and PCR results (P< .001; cycle threshold value range, 33.3-39.4), with SW statistically superior (P< .001) to all 3 alcohol-based hand rubs, although the actual difference was only 1-100 virus copies/microL. There was minimal reduction in H1N1 after 60 min without HH. HH with SW or alcohol-based hand rub is highly effective in reducing influenza A virus on human hands, although SW is the most effective intervention. Appropriate HH may be an important public health initiative to reduce pandemic and avian influenza transmission.

  15. Recent advances in biodynamics of human hand-arm system.

    Science.gov (United States)

    Dong, Ren G; Wu, John Z; Welcome, Daniel E

    2005-07-01

    The biodynamics of human hand-arm system is one of the most important foundations for the measurement, evaluation, and risk assessment of hand-transmitted vibration (HTV) exposure. This paper presents a new conceptual model relating factors influencing cause-effect relationships for HTV exposure, a new study strategy, and a comprehensive review of the recent advances in the biodynamics closely associated with HTV exposure. The review covers the following five aspects: theoretical modeling of biodynamic responses, vibration transmissibility, driving-point biodynamic responses, evaluation of anti-vibration gloves, and applied forces. This review finds that some significant advances in each of these aspects have been achieved in the recent years. Several important issues and problems in the biodynamic measurement have been identified and resolved, which has significantly helped improve the reliability and accuracy of the experimental data. The results reported in recent years suggest that, from the point of view of biodynamics, the frequency weighting specified in ISO 5349-1 (2001) overestimates the low frequency effect but underestimates the high frequency effect on the fingers and hand. The major problems, issues, and topics for further studies are also outlined in this paper. It is anticipated that the further studies of the biodynamics of the system will eventually lead to establishment of a robust vibration exposure theory. Although this review focuses on the biodynamics of the hand-arm system, the fundamental concepts and some methodologies reviewed in this paper may also be applicable for the study of whole-body vibration exposure.

  16. Systems biology from micro-organisms to human metabolic diseases: the role of detailed kinetic models.

    Science.gov (United States)

    Bakker, Barbara M; van Eunen, Karen; Jeneson, Jeroen A L; van Riel, Natal A W; Bruggeman, Frank J; Teusink, Bas

    2010-10-01

    Human metabolic diseases are typically network diseases. This holds not only for multifactorial diseases, such as metabolic syndrome or Type 2 diabetes, but even when a single gene defect is the primary cause, where the adaptive response of the entire network determines the severity of disease. The latter may differ between individuals carrying the same mutation. Understanding the adaptive responses of human metabolism naturally requires a systems biology approach. Modelling of metabolic pathways in micro-organisms and some mammalian tissues has yielded many insights, qualitative as well as quantitative, into their control and regulation. Yet, even for a well-known pathway such as glycolysis, precise predictions of metabolite dynamics from experimentally determined enzyme kinetics have been only moderately successful. In the present review, we compare kinetic models of glycolysis in three cell types (African trypanosomes, yeast and skeletal muscle), evaluate their predictive power and identify limitations in our understanding. Although each of these models has its own merits and shortcomings, they also share common features. For example, in each case independently measured enzyme kinetic parameters were used as input. Based on these 'lessons from glycolysis', we will discuss how to make best use of kinetic computer models to advance our understanding of human metabolic diseases.

  17. Assessing the impact of the regular use (4 weeks of an alcohol-based hand sanitizer on TEWL and epidermal hydration

    Directory of Open Access Journals (Sweden)

    Henrique Silva

    2015-12-01

    Full Text Available The Stratum corneum is a principal protector against physical, chemical, biological aggression and water loss in human skin. The repeated use of alcohol-based hand sanitizers might result in dryness and aggression. This study aims to evaluate the impact of a four week-long regular use of an alcohol-based gel hand sanitizer on skin hydration on the epidermal ‘barrier’ function using a kinetic model to quantify TEWL desorption curves following a POST test. A group of 13 female (19.7 ± 1.0 years old washed one of their hands for 29 consecutive days with a commercially available ethanol-based gel sanitizer. TEWL, superficial hydration (SH and deep hydration (DH were measured on days 1, 8, 15, 22 and 29, while a continuous TEWL recording following a 24 hour POST was made on days 1, 15 and 29 on a second skin area. No differences were found for the control hand throughout the study. For the test hand an increase of TEWL was found between days 1 and 8, as well as an increase of SH and DH between days 1 and 22. No significant differences were found for the kinetic parameters. These results suggest that the frequent use of the sanitizer gel might alter the skin barrier function.

  18. iHand: an interactive bare-hand-based augmented reality interface on commercial mobile phones

    Science.gov (United States)

    Choi, Junyeong; Park, Jungsik; Park, Hanhoon; Park, Jong-Il

    2013-02-01

    The performance of mobile phones has rapidly improved, and they are emerging as a powerful platform. In many vision-based applications, human hands play a key role in natural interaction. However, relatively little attention has been paid to the interaction between human hands and the mobile phone. Thus, we propose a vision- and hand gesture-based interface in which the user holds a mobile phone in one hand but sees the other hand's palm through a built-in camera. The virtual contents are faithfully rendered on the user's palm through palm pose estimation, and reaction with hand and finger movements is achieved that is recognized by hand shape recognition. Since the proposed interface is based on hand gestures familiar to humans and does not require any additional sensors or markers, the user can freely interact with virtual contents anytime and anywhere without any training. We demonstrate that the proposed interface works at over 15 fps on a commercial mobile phone with a 1.2-GHz dual core processor and 1 GB RAM.

  19. Kinetic Tremor: Differences Between Smokers and Non-smokers

    OpenAIRE

    Louis, Elan D.

    2006-01-01

    Tremor is among the acute effects of nicotine exposure. Published studies have focused on smoking-related postural (static) hand tremor rather than kinetic tremor (tremor during hand use), and gender differences in smoking-related tremor have not been examined. In a group of adults who were sampled from a population (mean ± SD = 65.7 ± 11.5 years, range = 18 - 92 years), the investigator assessed whether the severity of postural and kinetic tremors differed in smokers versus non-smokers, and ...

  20. The importance of inclusion of kinetic information in the extrapolation of high-to-low concentrations for human limit setting.

    Science.gov (United States)

    Geraets, Liesbeth; Zeilmaker, Marco J; Bos, Peter M J

    2018-01-05

    Human health risk assessment of inhalation exposures generally includes a high-to-low concentration extrapolation. Although this is a common step in human risk assessment, it introduces various uncertainties. One of these uncertainties is related to the toxicokinetics. Many kinetic processes such as absorption, metabolism or excretion can be subject to saturation at high concentration levels. In the presence of saturable kinetic processes of the parent compound or metabolites, disproportionate increases in internal blood or tissue concentration relative to the external concentration administered may occur resulting in nonlinear kinetics. The present paper critically reviews human health risk assessment of inhalation exposure. More specific, it emphasizes the importance of kinetic information for the determination of a safe exposure in human risk assessment of inhalation exposures assessed by conversion from a high animal exposure to a low exposure in humans. For two selected chemicals, i.e. methyl tert-butyl ether and 1,2-dichloroethane, PBTK-modelling was used, for illustrative purposes, to follow the extrapolation and conversion steps as performed in existing risk assessments for these chemicals. Human health-based limit values based on an external dose metric without sufficient knowledge on kinetics might be too high to be sufficiently protective. Insight in the actual internal exposure, the toxic agent, the appropriate dose metric, and whether an effect is related to internal concentration or dose is important. Without this, application of assessment factors on an external dose metric and the conversion to continuous exposure results in an uncertain human health risk assessment of inhalation exposures. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. In a demanding task, three-handed manipulation is preferred to two-handed manipulation.

    Science.gov (United States)

    Abdi, Elahe; Burdet, Etienne; Bouri, Mohamed; Himidan, Sharifa; Bleuler, Hannes

    2016-02-25

    Equipped with a third hand under their direct control, surgeons may be able to perform certain surgical interventions alone; this would reduce the need for a human assistant and related coordination difficulties. However, does human performance improve with three hands compared to two hands? To evaluate this possibility, we carried out a behavioural study on the performance of naive adults catching objects with three virtual hands controlled by their two hands and right foot. The subjects could successfully control the virtual hands in a few trials. With this control strategy, the workspace of the hands was inversely correlated with the task velocity. The comparison of performance between the three and two hands control revealed no significant difference of success in catching falling objects and in average effort during the tasks. Subjects preferred the three handed control strategy, found it easier, with less physical and mental burden. Although the coordination of the foot with the natural hands increased trial after trial, about two minutes of practice was not sufficient to develop a sense of ownership towards the third arm.

  2. Kinetic analysis of interactions of paraoxon and oximes with human, Rhesus monkey, swine, rabbit, rat and guinea pig acetylcholinesterase.

    Science.gov (United States)

    Worek, Franz; Aurbek, Nadine; Wille, Timo; Eyer, Peter; Thiermann, Horst

    2011-01-15

    Previous in vitro studies showed marked species differences in the reactivating efficiency of oximes between human and animal acetylcholinesterase (AChE) inhibited by organophosphorus (OP) nerve agents. These findings provoked the present in vitro study which was designed to determine the inhibition, aging, spontaneous and oxime-induced reactivation kinetics of the pesticide paraoxon, serving as a model compound for diethyl-OP, and the oximes obidoxime, pralidoxime, HI 6 and MMB-4 with human, Rhesus monkey, swine, rabbit, rat and guinea pig erythrocyte AChE. Comparable results were obtained with human and monkey AChE. Differences between human, swine, rabbit, rat and guinea pig AChE were determined for the inhibition and reactivation kinetics. A six-fold difference of the inhibitory potency of paraoxon with human and guinea pig AChE was recorded while only moderate differences of the reactivation constants between human and animal AChE were determined. Obidoxime was by far the most effective reactivator with all tested species. Only minor species differences were found for the aging and spontaneous reactivation kinetics. The results of the present study underline the necessity to determine the inhibition, aging and reactivation kinetics in vitro as a basis for the development of meaningful therapeutic animal models, for the proper assessment of in vivo animal data and for the extrapolation of animal data to humans. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Kinetic Constrained Optimization of the Golf Swing Hub Path

    Directory of Open Access Journals (Sweden)

    Steven M. Nesbit

    2014-12-01

    Full Text Available This study details an optimization of the golf swing, where the hand path and club angular trajectories are manipulated. The optimization goal was to maximize club head velocity at impact within the interaction kinetic limitations (force, torque, work, and power of the golfer as determined through the analysis of a typical swing using a two-dimensional dynamic model. The study was applied to four subjects with diverse swing capabilities and styles. It was determined that it is possible for all subjects to increase their club head velocity at impact within their respective kinetic limitations through combined modifications to their respective hand path and club angular trajectories. The manner of the modifications, the degree of velocity improvement, the amount of kinetic reduction, and the associated kinetic limitation quantities were subject dependent. By artificially minimizing selected kinetic inputs within the optimization algorithm, it was possible to identify swing trajectory characteristics that indicated relative kinetic weaknesses of a subject. Practical implications are offered based upon the findings of the study.

  4. Evaluation of the interindividual human variation in bioactivation of methyleugenol using physiologically based kinetic modeling and Monte Carlo simulations

    International Nuclear Information System (INIS)

    Al-Subeihi, Ala' A.A.; Alhusainy, Wasma; Kiwamoto, Reiko; Spenkelink, Bert; Bladeren, Peter J. van; Rietjens, Ivonne M.C.M.; Punt, Ans

    2015-01-01

    The present study aims at predicting the level of formation of the ultimate carcinogenic metabolite of methyleugenol, 1′-sulfooxymethyleugenol, in the human population by taking variability in key bioactivation and detoxification reactions into account using Monte Carlo simulations. Depending on the metabolic route, variation was simulated based on kinetic constants obtained from incubations with a range of individual human liver fractions or by combining kinetic constants obtained for specific isoenzymes with literature reported human variation in the activity of these enzymes. The results of the study indicate that formation of 1′-sulfooxymethyleugenol is predominantly affected by variation in i) P450 1A2-catalyzed bioactivation of methyleugenol to 1′-hydroxymethyleugenol, ii) P450 2B6-catalyzed epoxidation of methyleugenol, iii) the apparent kinetic constants for oxidation of 1′-hydroxymethyleugenol, and iv) the apparent kinetic constants for sulfation of 1′-hydroxymethyleugenol. Based on the Monte Carlo simulations a so-called chemical-specific adjustment factor (CSAF) for intraspecies variation could be derived by dividing different percentiles by the 50th percentile of the predicted population distribution for 1′-sulfooxymethyleugenol formation. The obtained CSAF value at the 90th percentile was 3.2, indicating that the default uncertainty factor of 3.16 for human variability in kinetics may adequately cover the variation within 90% of the population. Covering 99% of the population requires a larger uncertainty factor of 6.4. In conclusion, the results showed that adequate predictions on interindividual human variation can be made with Monte Carlo-based PBK modeling. For methyleugenol this variation was observed to be in line with the default variation generally assumed in risk assessment. - Highlights: • Interindividual human differences in methyleugenol bioactivation were simulated. • This was done using in vitro incubations, PBK modeling

  5. Evaluation of the interindividual human variation in bioactivation of methyleugenol using physiologically based kinetic modeling and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Al-Subeihi, Ala' A.A., E-mail: subeihi@yahoo.com [Division of Toxicology, Wageningen University, Tuinlaan 5, 6703 HE Wageningen (Netherlands); BEN-HAYYAN-Aqaba International Laboratories, Aqaba Special Economic Zone Authority (ASEZA), P. O. Box 2565, Aqaba 77110 (Jordan); Alhusainy, Wasma; Kiwamoto, Reiko; Spenkelink, Bert [Division of Toxicology, Wageningen University, Tuinlaan 5, 6703 HE Wageningen (Netherlands); Bladeren, Peter J. van [Division of Toxicology, Wageningen University, Tuinlaan 5, 6703 HE Wageningen (Netherlands); Nestec S.A., Avenue Nestlé 55, 1800 Vevey (Switzerland); Rietjens, Ivonne M.C.M.; Punt, Ans [Division of Toxicology, Wageningen University, Tuinlaan 5, 6703 HE Wageningen (Netherlands)

    2015-03-01

    The present study aims at predicting the level of formation of the ultimate carcinogenic metabolite of methyleugenol, 1′-sulfooxymethyleugenol, in the human population by taking variability in key bioactivation and detoxification reactions into account using Monte Carlo simulations. Depending on the metabolic route, variation was simulated based on kinetic constants obtained from incubations with a range of individual human liver fractions or by combining kinetic constants obtained for specific isoenzymes with literature reported human variation in the activity of these enzymes. The results of the study indicate that formation of 1′-sulfooxymethyleugenol is predominantly affected by variation in i) P450 1A2-catalyzed bioactivation of methyleugenol to 1′-hydroxymethyleugenol, ii) P450 2B6-catalyzed epoxidation of methyleugenol, iii) the apparent kinetic constants for oxidation of 1′-hydroxymethyleugenol, and iv) the apparent kinetic constants for sulfation of 1′-hydroxymethyleugenol. Based on the Monte Carlo simulations a so-called chemical-specific adjustment factor (CSAF) for intraspecies variation could be derived by dividing different percentiles by the 50th percentile of the predicted population distribution for 1′-sulfooxymethyleugenol formation. The obtained CSAF value at the 90th percentile was 3.2, indicating that the default uncertainty factor of 3.16 for human variability in kinetics may adequately cover the variation within 90% of the population. Covering 99% of the population requires a larger uncertainty factor of 6.4. In conclusion, the results showed that adequate predictions on interindividual human variation can be made with Monte Carlo-based PBK modeling. For methyleugenol this variation was observed to be in line with the default variation generally assumed in risk assessment. - Highlights: • Interindividual human differences in methyleugenol bioactivation were simulated. • This was done using in vitro incubations, PBK modeling

  6. Chloroform and trichloroethylene uptake from water into human skin in vitro: Kinetics and risk implications

    International Nuclear Information System (INIS)

    Bogen, K.T.; Keating, G.A.; Vogel, J.S.

    1995-03-01

    A model recently proposed by the US Environmental Protection Agency (EPA) predicts that short-term dermal uptakes of organic environmental water contaminants are proportional to the square root of exposure time. The model appears to underestimate dermal uptake, based on very limited in vivo uptake data obtained primarily using human subjects. To further assess this model, we examined in vitro dermal uptake kinetics for aqueous organic chemicals using accelerator mass spectrometry (AMS). Specifically, we examined the kinetics of in vitro dermal uptake of 14 C-labeled chloroform and trichloroethylene from dilute (5-ppb) aqueous solutions using full-thickness human cadaver skin exposed for (≤1 hr)

  7. Involuntary human hand movements due to FM radio waves in a moving van.

    Science.gov (United States)

    Huttunen, P; Savinainen, A; Hänninen, Osmo; Myllylä, R

    2011-06-01

    Finland TRACT Involuntary movements of hands in a moving van on a public road were studied to clarify the possible role of frequency modulated radio waves on driving. The signals were measured in a direct 2 km test segment of an international road during repeated drives to both directions. Test subjects (n=4) had an ability to sense radio frequency field intensity variations of the environment. They were sitting in a minivan with arm movement detectors in their hands. A potentiometer was used to register the hand movements to a computer which simultaneously collected data on the amplitude of the RF signal of the local FM tower 30 km distance at a frequency of about 100 MHz. Involuntary hand movements of the test subjects correlated with electromagnetic field, i.e. FM radio wave intensity measured. They reacted also on the place of a geomagnetic anomaly crossing the road, which was found on the basis of these recordings and confirmed by the public geological maps of the area.In conclusion, RF irradiation seems to affect the human hand reflexes of sensitive persons in a moving van along a normal public road which may have significance in traffic safety.

  8. Human erythrocyte electrofusion kinetics monitored by aqueous contents mixing.

    OpenAIRE

    Stenger, D A; Hui, S W

    1988-01-01

    The kinetics of electrically induced fusion of human erythrocyte ghosts were monitored by the Tb/DPA and ANTS/DPX fluorescence fusion assays. Ghosts were aligned by dielectrophoresis using a 3-MHz 350-V/cm alternating field and were fused by single 15- or 50-microseconds electric field pulses of amplitude 2.5-5.0 kV/cm. Fusion was detected immediately after the pulse. The peak fluorescence change due to fusion was always obtained within 7 s of pulse application, and was highest for a 5.0 kV/c...

  9. Bringing transcranial mapping into shape: Sulcus-aligned mapping captures motor somatotopy in human primary motor hand area

    DEFF Research Database (Denmark)

    Raffin, Estelle; Pellegrino, Giovanni; Di Lazzaro, Vincenzo

    2015-01-01

    Motor representations express some degree of somatotopy in human primary motor hand area (M1HAND), but within-M1HAND corticomotor somatotopy has been difficult to study with transcranial magnetic stimulation (TMS). Here we introduce a “linear” TMS mapping approach based on the individual shape...... of the central sulcus to obtain mediolateral corticomotor excitability profiles of the abductor digiti minimi (ADM) and first dorsal interosseus (FDI) muscles. In thirteen young volunteers, we used stereotactic neuronavigation to stimulate the right M1HAND with a small eight-shaped coil at 120% of FDI resting...

  10. Systems biology of coagulation initiation: kinetics of thrombin generation in resting and activated human blood.

    Directory of Open Access Journals (Sweden)

    Manash S Chatterjee

    2010-09-01

    Full Text Available Blood function defines bleeding and clotting risks and dictates approaches for clinical intervention. Independent of adding exogenous tissue factor (TF, human blood treated in vitro with corn trypsin inhibitor (CTI, to block Factor XIIa will generate thrombin after an initiation time (T(i of 1 to 2 hours (depending on donor, while activation of platelets with the GPVI-activator convulxin reduces T(i to ∼20 minutes. Since current kinetic models fail to generate thrombin in the absence of added TF, we implemented a Platelet-Plasma ODE model accounting for: the Hockin-Mann protease reaction network, thrombin-dependent display of platelet phosphatidylserine, VIIa function on activated platelets, XIIa and XIa generation and function, competitive thrombin substrates (fluorogenic detector and fibrinogen, and thrombin consumption during fibrin polymerization. The kinetic model consisting of 76 ordinary differential equations (76 species, 57 reactions, 105 kinetic parameters predicted the clotting of resting and convulxin-activated human blood as well as predicted T(i of human blood under 50 different initial conditions that titrated increasing levels of TF, Xa, Va, XIa, IXa, and VIIa. Experiments with combined anti-XI and anti-XII antibodies prevented thrombin production, demonstrating that a leak of XIIa past saturating amounts of CTI (and not "blood-borne TF" alone was responsible for in vitro initiation without added TF. Clotting was not blocked by antibodies used individually against TF, VII/VIIa, P-selectin, GPIb, protein disulfide isomerase, cathepsin G, nor blocked by the ribosome inhibitor puromycin, the Clk1 kinase inhibitor Tg003, or inhibited VIIa (VIIai. This is the first model to predict the observed behavior of CTI-treated human blood, either resting or stimulated with platelet activators. CTI-treated human blood will clot in vitro due to the combined activity of XIIa and XIa, a process enhanced by platelet activators and which proceeds

  11. Physiological and subjective evaluation of a human-robot object hand-over task.

    Science.gov (United States)

    Dehais, Frédéric; Sisbot, Emrah Akin; Alami, Rachid; Causse, Mickaël

    2011-11-01

    In the context of task sharing between a robot companion and its human partners, the notions of safe and compliant hardware are not enough. It is necessary to guarantee ergonomic robot motions. Therefore, we have developed Human Aware Manipulation Planner (Sisbot et al., 2010), a motion planner specifically designed for human-robot object transfer by explicitly taking into account the legibility, the safety and the physical comfort of robot motions. The main objective of this research was to define precise subjective metrics to assess our planner when a human interacts with a robot in an object hand-over task. A second objective was to obtain quantitative data to evaluate the effect of this interaction. Given the short duration, the "relative ease" of the object hand-over task and its qualitative component, classical behavioral measures based on accuracy or reaction time were unsuitable to compare our gestures. In this perspective, we selected three measurements based on the galvanic skin conductance response, the deltoid muscle activity and the ocular activity. To test our assumptions and validate our planner, an experimental set-up involving Jido, a mobile manipulator robot, and a seated human was proposed. For the purpose of the experiment, we have defined three motions that combine different levels of legibility, safety and physical comfort values. After each robot gesture the participants were asked to rate them on a three dimensional subjective scale. It has appeared that the subjective data were in favor of our reference motion. Eventually the three motions elicited different physiological and ocular responses that could be used to partially discriminate them. Copyright © 2011 Elsevier Ltd and the Ergonomics Society. All rights reserved.

  12. Radiosensitivity and cell kinetics of the human solid cancer transplanted to nude mouse

    International Nuclear Information System (INIS)

    Ikeuchi, Shunji

    1983-01-01

    This study was undertaken to analyse the relationship between radiosensitivity and cell kinetics of human solid cancer in experimental nude mouse system. Four strains of tumors used for the experiment were poorly differentiated squamous cell carcinoma of the lung (Lu-9), oat cell carcinoma of the lung (Lu-24), well differentiated squamous cell carcinoma of the tongue (To-1) and moderately differentiated squamous cell carcinoma of the esophagus (Es-4) which were serially transplantable to BALB/c nude mice. Radiosensitivity was evaluated by tumor growth in terms of inhibition rate, histological change and host reaction after irradiation. Cell kinetics were studied by autoradiography with pulse administration of 3 H-thymidine to mice. Although Lu-24 was most radiosensitive, followed by To-1, Es-4 and Lu-9 in the order of sensitivity, it was suggested that they might be more radioresistant in nude mice without T-cell function than in human. Regarding squamous cell carcinomas, well differentiated type was more radiosensitive than poorly differentiated one. All of these tumors in nude mouse revealed distinct percent labeled mitosis curves with two clear peaks which were quite different from those in human body. Lu-24 showed a characteristic pattern with a long time lag before visible growth, short G 1 , and low growth fraction, compared to other three tumors. Three strains of squamous cell carcinoma demonstrated similar cell kinetic factors which were almost the same as those in human body reported previously. The differences in volume doubling time of tumor, growth fraction and cell loss factor were partially related to those of radiosensitivities among tumors except for Lu-24. The theoretical volume doubling time was proved to be most reliable for estimation of effectiveness of irradiation, but the labeling index was not a valuable indicator for it. (author)

  13. Perseveration Found in a Human Drawing Task: Six-Fingered Hands Drawn by Patients with Right Anterior Insula and Operculum Damage

    Directory of Open Access Journals (Sweden)

    Chiharu Niki

    2014-01-01

    Full Text Available Background. Perseveration has been observed in a number of behavioural contexts, including speaking, writing, and drawing. However, no previous report describes patients who show perseveration only for drawing a human figure. Objective. The present report describes a group of patients who show body awareness-related cognitive impairment during a human figure drawing task, a different presentation from previously described neuropsychological cases. Methods. Participants were 15 patients who had a frontal lobe brain tumour around the insula cortex of the right hemisphere and had subsequently undergone a neurosurgical resective operation. Participants were asked to draw a human figure in both “hands-down” and “hands-up” configurations. Results. Eight of the 15 patients drew a human figure with six fingers during the “hands-up” and the “hands-down” human figure drawing tasks (one patient drew eight fingers. A statistical analysis of potential lesion areas revealed damage to the right anterior frontal insula and operculum in this group of patients relative to the five-finger drawing group. Conclusions. Our findings reveal a newly described neuropsychological phenomenon that could reflect impairment in attention directed towards body representations.

  14. Perseveration Found in a Human Drawing Task: Six-Fingered Hands Drawn by Patients with Right Anterior Insula and Operculum Damage

    Science.gov (United States)

    Niki, Chiharu; Maruyama, Takashi; Muragaki, Yoshihiro; Kumada, Takatsune

    2014-01-01

    Background. Perseveration has been observed in a number of behavioural contexts, including speaking, writing, and drawing. However, no previous report describes patients who show perseveration only for drawing a human figure. Objective. The present report describes a group of patients who show body awareness-related cognitive impairment during a human figure drawing task, a different presentation from previously described neuropsychological cases. Methods. Participants were 15 patients who had a frontal lobe brain tumour around the insula cortex of the right hemisphere and had subsequently undergone a neurosurgical resective operation. Participants were asked to draw a human figure in both “hands-down” and “hands-up” configurations. Results. Eight of the 15 patients drew a human figure with six fingers during the “hands-up” and the “hands-down” human figure drawing tasks (one patient drew eight fingers). A statistical analysis of potential lesion areas revealed damage to the right anterior frontal insula and operculum in this group of patients relative to the five-finger drawing group. Conclusions. Our findings reveal a newly described neuropsychological phenomenon that could reflect impairment in attention directed towards body representations. PMID:24876665

  15. Mathematical modeling provides kinetic details of the human immune response to vaccination

    Directory of Open Access Journals (Sweden)

    Dustin eLe

    2015-01-01

    Full Text Available With major advances in experimental techniques to track antigen-specific immune responses many basic questions on the kinetics of virus-specific immunity in humans remain unanswered. To gain insights into kinetics of T and B cell responses in human volunteers we combine mathematical models and experimental data from recent studies employing vaccines against yellow fever and smallpox. Yellow fever virus-specific CD8 T cell population expanded slowly with the average doubling time of 2 days peaking 2.5 weeks post immunization. Interestingly, we found that the peak of the yellow fever-specific CD8 T cell response is determined by the rate of T cell proliferation and not by the precursor frequency of antigen-specific cells as has been suggested in several studies in mice. We also found that while the frequency of virus-specific T cells increases slowly, the slow increase can still accurately explain clearance of yellow fever virus in the blood. Our additional mathematical model describes well the kinetics of virus-specific antibody-secreting cell and antibody response to vaccinia virus in vaccinated individuals suggesting that most of antibodies in 3 months post immunization are derived from the population of circulating antibody-secreting cells. Taken together, our analysis provides novel insights into mechanisms by which live vaccines induce immunity to viral infections and highlight challenges of applying methods of mathematical modeling to the current, state-of-the-art yet limited immunological data.

  16. Mathematical modeling provides kinetic details of the human immune response to vaccination.

    Science.gov (United States)

    Le, Dustin; Miller, Joseph D; Ganusov, Vitaly V

    2014-01-01

    With major advances in experimental techniques to track antigen-specific immune responses many basic questions on the kinetics of virus-specific immunity in humans remain unanswered. To gain insights into kinetics of T and B cell responses in human volunteers we combined mathematical models and experimental data from recent studies employing vaccines against yellow fever and smallpox. Yellow fever virus-specific CD8 T cell population expanded slowly with the average doubling time of 2 days peaking 2.5 weeks post immunization. Interestingly, we found that the peak of the yellow fever-specific CD8 T cell response was determined by the rate of T cell proliferation and not by the precursor frequency of antigen-specific cells as has been suggested in several studies in mice. We also found that while the frequency of virus-specific T cells increased slowly, the slow increase could still accurately explain clearance of yellow fever virus in the blood. Our additional mathematical model described well the kinetics of virus-specific antibody-secreting cell and antibody response to vaccinia virus in vaccinated individuals suggesting that most of antibodies in 3 months post immunization were derived from the population of circulating antibody-secreting cells. Taken together, our analysis provided novel insights into mechanisms by which live vaccines induce immunity to viral infections and highlighted challenges of applying methods of mathematical modeling to the current, state-of-the-art yet limited immunological data.

  17. A word in the hand: action, gesture and mental representation in humans and non-human primates

    Science.gov (United States)

    Cartmill, Erica A.; Beilock, Sian; Goldin-Meadow, Susan

    2012-01-01

    The movements we make with our hands both reflect our mental processes and help to shape them. Our actions and gestures can affect our mental representations of actions and objects. In this paper, we explore the relationship between action, gesture and thought in both humans and non-human primates and discuss its role in the evolution of language. Human gesture (specifically representational gesture) may provide a unique link between action and mental representation. It is kinaesthetically close to action and is, at the same time, symbolic. Non-human primates use gesture frequently to communicate, and do so flexibly. However, their gestures mainly resemble incomplete actions and lack the representational elements that characterize much of human gesture. Differences in the mirror neuron system provide a potential explanation for non-human primates' lack of representational gestures; the monkey mirror system does not respond to representational gestures, while the human system does. In humans, gesture grounds mental representation in action, but there is no evidence for this link in other primates. We argue that gesture played an important role in the transition to symbolic thought and language in human evolution, following a cognitive leap that allowed gesture to incorporate representational elements. PMID:22106432

  18. Kinetics of thymine dimer excision in ultraviolet-irradiated human cells

    International Nuclear Information System (INIS)

    Ehmann, U.K.; Cook, K.H.; Friedberg, E.C.

    1978-01-01

    We have investigated the kinetics of the loss of thymine dimers from the acid-insoluble fraction of several ultraviolet (uv)-irradiated cultured human cell lines. Our results show that uv fluences between 10 and 40 J/m 2 produce an average of 21 to 85 x 10 5 thymine dimers per cell and an eventual maximal loss per cell of 12 to 20 x 10 5 thymine dimers. The time for half-maximal loss of dimers ranged from 12 to 22 h after uv irradiation. In contrast, the time for half-maximal repair synthesis of DNA measured by autoradiography was 4.5 h. This figure agrees well with reported half-maximal repair synthesis times, which range from 0.5 to 3.6 h based on our analysis. The discrepancy in the kinetics of the loss of thymine dimers from DNA and repair synthesis is discussed in terms of possible molecular mechanisms of thymine dimer excision in vivo and in terms of possible experimental artifacts

  19. Lithium hydride hydrolysis: experimental and kinetic study

    International Nuclear Information System (INIS)

    Charton, S.; Maupoix, C.; Brevet, A.; Delaunay, F.; Heintz, O.; Saviot, L.

    2006-01-01

    In this work has been studied the contribution of various analyses techniques in the framework, on the one hand of revealing the mechanisms implied in lithium hydride hydrolysis, and on the other hand of studying the kinetics of hydrogen production. Among the methods recently investigated, Raman spectroscopy, XPS and SIMS seem to be particularly attractive. (O.M.)

  20. An automated hand hygiene compliance system is associated with improved monitoring of hand hygiene.

    Science.gov (United States)

    McCalla, Saungi; Reilly, Maggie; Thomas, Rowena; McSpedon-Rai, Dawn

    2017-05-01

    Consistent hand hygiene is key to reducing health care-associated infections (HAIs) and assessing compliance with hand hygiene protocols is vital for hospital infection control staff. A new automated hand hygiene compliance system (HHCS) was trialed as an alternative to human observers in an intensive care unit and an intensive care stepdown unit at a hospital facility in the northeastern United States. Using a retrospective cohort design, researchers investigated whether implementation of the HHCS resulted in improved hand hygiene compliance and a reduction in common HAI rates. Pearson χ 2 tests were used to assess changes in compliance, and incidence rate ratios were used to test for significant differences in infection rates. During the study period, the HHCS collected many more hand hygiene events compared with human observers (632,404 vs 480) and ensured that the hospital met its compliance goals (95%+). Although decreases in multidrug-resistant organisms, central line-associated bloodstream infections, and catheter-associated urinary tract infection rates were observed, they represented nonsignificant differences. Human hand hygiene observers may not report accurate measures of compliance. The HHCS is a promising new tool for fine-grained assessment of hand hygiene compliance. Further study is needed to examine the association between the HHCS and HAI rate reduction. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. Anthropomorphic Robot Hand And Teaching Glove

    Science.gov (United States)

    Engler, Charles D., Jr.

    1991-01-01

    Robotic forearm-and-hand assembly manipulates objects by performing wrist and hand motions with nearly human grasping ability and dexterity. Imitates hand motions of human operator who controls robot in real time by programming via exoskeletal "teaching glove". Telemanipulator systems based on this robotic-hand concept useful where humanlike dexterity required. Underwater, high-radiation, vacuum, hot, cold, toxic, or inhospitable environments potential application sites. Particularly suited to assisting astronauts on space station in safely executing unexpected tasks requiring greater dexterity than standard gripper.

  2. Study of kinetics of 2,3-diphosphoglycerate degradation by 31P-NMR technique in depleted human erythrocytes

    International Nuclear Information System (INIS)

    Ataullakhanov, F.I.; Vitvitskii, V.M.; Dubinskaya, E.I.; Dubinskii, V.Z.

    1986-01-01

    The kinetics of 2,3-diphosphoglycerate degradation in depleted human erythrocytes was studied by the high-resolution 31 P-NMR technique. A plateau was found on the kinetic curve in the first 1.5-2 h after the beginning of depletion. The mechanisms that may be responsible for the existence of such a plateau are discussed

  3. Learning robotic eye-arm-hand coordination from human demonstration: a coupled dynamical systems approach.

    Science.gov (United States)

    Lukic, Luka; Santos-Victor, José; Billard, Aude

    2014-04-01

    We investigate the role of obstacle avoidance in visually guided reaching and grasping movements. We report on a human study in which subjects performed prehensile motion with obstacle avoidance where the position of the obstacle was systematically varied across trials. These experiments suggest that reaching with obstacle avoidance is organized in a sequential manner, where the obstacle acts as an intermediary target. Furthermore, we demonstrate that the notion of workspace travelled by the hand is embedded explicitly in a forward planning scheme, which is actively involved in detecting obstacles on the way when performing reaching. We find that the gaze proactively coordinates the pattern of eye-arm motion during obstacle avoidance. This study provides also a quantitative assessment of the coupling between the eye-arm-hand motion. We show that the coupling follows regular phase dependencies and is unaltered during obstacle avoidance. These observations provide a basis for the design of a computational model. Our controller extends the coupled dynamical systems framework and provides fast and synchronous control of the eyes, the arm and the hand within a single and compact framework, mimicking similar control system found in humans. We validate our model for visuomotor control of a humanoid robot.

  4. Shape-estimation of human hand using polymer flex sensor and study of its application to control robot arm

    International Nuclear Information System (INIS)

    Lee, Jin Hyuck; Kim, Dae Hyun

    2015-01-01

    Ultrasonic inspection robot systems have been widely researched and developed for the real-time monitoring of structures such as power plants. However, an inspection robot that is operated in a simple pattern has limitations in its application to various structures in a plant facility because of the diverse and complicated shapes of the inspection objects. Therefore, accurate control of the robot is required to inspect complicated objects with high-precision results. This paper presents the idea that the shape and movement information of an ultrasonic inspector's hand could be profitably utilized for the accurate control of robot. In this study, a polymer flex sensor was applied to monitor the shape of a human hand. This application was designed to intuitively control an ultrasonic inspection robot. The movement and shape of the hand were estimated by applying multiple sensors. Moreover, it was successfully shown that a test robot could be intuitively controlled based on the shape of a human hand estimated using polymer flex sensors.

  5. Shape-estimation of human hand using polymer flex sensor and study of its application to control robot arm

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hyuck; Kim, Dae Hyun [Seoul National University of Technology, Seoul (Korea, Republic of)

    2015-02-15

    Ultrasonic inspection robot systems have been widely researched and developed for the real-time monitoring of structures such as power plants. However, an inspection robot that is operated in a simple pattern has limitations in its application to various structures in a plant facility because of the diverse and complicated shapes of the inspection objects. Therefore, accurate control of the robot is required to inspect complicated objects with high-precision results. This paper presents the idea that the shape and movement information of an ultrasonic inspector's hand could be profitably utilized for the accurate control of robot. In this study, a polymer flex sensor was applied to monitor the shape of a human hand. This application was designed to intuitively control an ultrasonic inspection robot. The movement and shape of the hand were estimated by applying multiple sensors. Moreover, it was successfully shown that a test robot could be intuitively controlled based on the shape of a human hand estimated using polymer flex sensors.

  6. The hand of Homo naledi

    Science.gov (United States)

    Kivell, Tracy L.; Deane, Andrew S.; Tocheri, Matthew W.; Orr, Caley M.; Schmid, Peter; Hawks, John; Berger, Lee R.; Churchill, Steven E.

    2015-01-01

    A nearly complete right hand of an adult hominin was recovered from the Rising Star cave system, South Africa. Based on associated hominin material, the bones of this hand are attributed to Homo naledi. This hand reveals a long, robust thumb and derived wrist morphology that is shared with Neandertals and modern humans, and considered adaptive for intensified manual manipulation. However, the finger bones are longer and more curved than in most australopiths, indicating frequent use of the hand during life for strong grasping during locomotor climbing and suspension. These markedly curved digits in combination with an otherwise human-like wrist and palm indicate a significant degree of climbing, despite the derived nature of many aspects of the hand and other regions of the postcranial skeleton in H. naledi. PMID:26441219

  7. The basal kinetic parameters of glycogen synthase in human myotube cultures are not affected by chronic high insulin exposure

    DEFF Research Database (Denmark)

    Gaster, M; Schrøder, H D; Handberg, A

    2001-01-01

    results show that chronic exposure of human myotubes to high insulin with or without high glucose did not affect the basal kinetic parameters but abolished the reactivity of GS to acute insulin stimulation. We suggest that insulin induced insulin resistance of GS is caused by a failure of acute insulin......There is no consensus regarding the results from in vivo and in vitro studies on the impact of chronic high insulin and/or high glucose exposure on acute insulin stimulation of glycogen synthase (GS) kinetic parameters in human skeletal muscle. The aim of this study was to evaluate the kinetic...... parameters of glycogen synthase activity in human myotube cultures at conditions of chronic high insulin combined or not with high glucose exposure, before and after a subsequent acute insulin stimulation. Acute insulin stimulation significantly increased the fractional activity (FV(0.1)) of GS, increased...

  8. Analysis of the kinetic mechanism of recombinant human isoprenylcysteine carboxylmethyltransferase (Icmt

    Directory of Open Access Journals (Sweden)

    Baron Rudi A

    2004-12-01

    Full Text Available Abstract Background Isoprenylcysteine carboxyl methyltransferase (Icmt is the third of three enzymes that posttranslationally modify proteins that contain C-terminal CaaX motifs. The processing of CaaX proteins through this so-called prenylation pathway via a route initiated by addition of an isoprenoid lipid is required for both membrane targeting and function of the proteins. The involvement of many CaaX proteins such as Ras GTPases in oncogenesis and other aberrant proliferative disorders has led to the targeting of the enzymes involved in their processing for therapeutic development, necessitating a detailed understanding of the mechanisms of the enzymes. Results In this study, we have investigated the kinetic mechanism of recombinant human Icmt. In the reaction catalyzed by Icmt, S-adenosyl-L-methionine (AdoMet provides the methyl group that is transferred to the second substrate, the C-terminal isoprenylated cysteine residue of a CaaX protein, thereby generating a C-terminal prenylcysteine methyl ester on the protein. To facilitate the kinetic analysis of Icmt, we synthesized a new small molecule substrate of the enzyme, biotin-S-farnesyl-L-cysteine (BFC. Initial kinetic analysis of Icmt suggested a sequential mechanism for the enzyme that was further analyzed using a dead end competitive inhibitor, S-farnesylthioacetic acid (FTA. Inhibition by FTA was competitive with respect to BFC and uncompetitive with respect to AdoMet, indicating an ordered mechanism with SAM binding first. To investigate the order of product dissociation, product inhibition studies were undertaken with S-adenosyl-L-homocysteine (AdoHcy and the N-acetyl-S-farnesyl-L-cysteine methylester (AFCME. This analysis indicated that AdoHcy is a competitive inhibitor with respect to AdoMet, while AFCME shows a noncompetitive inhibition with respect to BFC and a mixed-type inhibition with respect to AdoMet. These studies established that AdoHcy is the final product released, and

  9. Dynamic PET of human liver inflammation: impact of kinetic modeling with optimization-derived dual-blood input function.

    Science.gov (United States)

    Wang, Guobao; Corwin, Michael T; Olson, Kristin A; Badawi, Ramsey D; Sarkar, Souvik

    2018-05-30

    The hallmark of nonalcoholic steatohepatitis is hepatocellular inflammation and injury in the setting of hepatic steatosis. Recent work has indicated that dynamic 18F-FDG PET with kinetic modeling has the potential to assess hepatic inflammation noninvasively, while static FDG-PET did not show a promise. Because the liver has dual blood supplies, kinetic modeling of dynamic liver PET data is challenging in human studies. The objective of this study is to evaluate and identify a dual-input kinetic modeling approach for dynamic FDG-PET of human liver inflammation. Fourteen human patients with nonalcoholic fatty liver disease were included in the study. Each patient underwent one-hour dynamic FDG-PET/CT scan and had liver biopsy within six weeks. Three models were tested for kinetic analysis: traditional two-tissue compartmental model with an image-derived single-blood input function (SBIF), model with population-based dual-blood input function (DBIF), and modified model with optimization-derived DBIF through a joint estimation framework. The three models were compared using Akaike information criterion (AIC), F test and histopathologic inflammation reference. The results showed that the optimization-derived DBIF model improved the fitting of liver time activity curves and achieved lower AIC values and higher F values than the SBIF and population-based DBIF models in all patients. The optimization-derived model significantly increased FDG K1 estimates by 101% and 27% as compared with traditional SBIF and population-based DBIF. K1 by the optimization-derived model was significantly associated with histopathologic grades of liver inflammation while the other two models did not provide a statistical significance. In conclusion, modeling of DBIF is critical for kinetic analysis of dynamic liver FDG-PET data in human studies. The optimization-derived DBIF model is more appropriate than SBIF and population-based DBIF for dynamic FDG-PET of liver inflammation. © 2018

  10. Kinetics of the Factor XIa catalyzed activation of human blood coagulation Factor IX

    International Nuclear Information System (INIS)

    Walsh, P.N.; Bradford, H.; Sinha, D.; Piperno, J.R.; Tuszynski, G.P.

    1984-01-01

    The kinetics of activation of human Factor IX by human Factor XIa was studied by measuring the release of a trichloroacetic acid-soluble tritium-labeled activation peptide from Factor IX. Initial rates of trichloroacetic acid-soluble 3 H-release were linear over 10-30 min of incubation of Factor IX (88 nM) with CaCl 2 (5 mM) and with pure (greater than 98%) Factor XIa (0.06-1.3 nM), which was prepared by incubating human Factor XI with bovine Factor XIIa. Release of 3 H preceded the appearance of Factor IXa activity, and the percentage of 3 H released remained constant when the mole fraction of 3 H-labeled and unlabeled Factor IX was varied and the total Factor IX concentration remained constant. A linear correlation (r greater than 0.98, P less than 0.001) was observed between initial rates of 3 H-release and the concentration of Factor XIa, measured by chromogenic assay and by radioimmunoassay and added at a Factor IX:Factor XIa molar ratio of 70-5,600. Kinetic parameters, determined by Lineweaver-Burk analysis, include K/sub m/ (0.49 microM) of about five- to sixfold higher than the plasma Factor IX concentration, which could therefore regulate the reaction. The catalytic constant (k/sub cat/) (7.7/s) is approximately 20-50 times higher than that reported by Zur and Nemerson for Factor IX activation by Factor VIIa plus tissue factor. Therefore, depending on the relative amounts of Factor XIa and Factor VIIa generated in vivo and other factors which may influence reaction rates, these kinetic parameters provide part of the information required for assessing the relative contributions of the intrinsic and extrinsic pathways to Factor IX activation, and suggest that the Factor XIa catalyzed reaction is physiologically significant

  11. Early Pleistocene human hand phalanx from the Sima del Elefante (TE) cave site in Sierra de Atapuerca (Spain).

    Science.gov (United States)

    Lorenzo, Carlos; Pablos, Adrián; Carretero, José Miguel; Huguet, Rosa; Valverdú, Josep; Martinón-Torres, María; Arsuaga, Juan Luis; Carbonell, Eudald; Bermúdez de Castro, José María

    2015-01-01

    In this study, a new Early Pleistocene proximal hand phalanx (ATE9-2) from the Sima del Elefante cave site (TE - Sierra de Atapuerca, Spain), ascribed to Homo sp., is presented and comparatively described in the context of the evolution of the genus Homo. The ATE9-2 specimen is especially important because of the paucity of hand bones in the human fossil record during the Early Pleistocene. The morphological and metrical analyses of the phalanx ATE9-2 indicate that there are no essential differences between it and comparator fossil specimens for the genus Homo after 1.3 Ma (millions of years ago). Similar to Sima de los Huesos and Neandertal specimens, ATE9-2 is a robust proximal hand phalanx, probably reflecting greater overall body robusticity in these populations or a higher gracility in modern humans. The age of level TE9 from Sima del Elefante and morphological and metrical studies of ATE9-2 suggest that the morphology of the proximal hand phalanges and, thus, the morphology of the hand could have remained stable over the last 1.2-1.3 Ma. Taking into account the evidence recently provided by a metacarpal from Kaitio (Kenya) from around 1.42 Ma, we argue that modern hand morphology is present in the genus Homo subsequent to Homo habilis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Development of five-finger robotic hand using master-slave control for hand-assisted laparoscopic surgery.

    Science.gov (United States)

    Yoshida, Koki; Yamada, Hiroshi; Kato, Ryu; Seki, Tatsuya; Yokoi, Hiroshi; Mukai, Masaya

    2016-08-01

    This study aims to develop a robotic hand as a substitute for a surgeon's hand in hand-assisted laparoscopic surgery (HALS). We determined the requirements for the proposed hand from a surgeon's motions in HALS. We identified four basic behaviors: "power grasp," "precision grasp," "open hand for exclusion," and "peace sign for extending peritoneum." The proposed hand had the minimum necessary DOFs for performing these behaviors, five fingers as in a human's hand, a palm that can be folded when a surgeon inserts the hand into the abdomen, and an arm for adjusting the hand's position. We evaluated the proposed hand based on a performance test and a physician's opinions, and we confirmed that it can grasp organs.

  13. 3D Printed Robotic Hand

    Science.gov (United States)

    Pizarro, Yaritzmar Rosario; Schuler, Jason M.; Lippitt, Thomas C.

    2013-01-01

    Dexterous robotic hands are changing the way robots and humans interact and use common tools. Unfortunately, the complexity of the joints and actuations drive up the manufacturing cost. Some cutting edge and commercially available rapid prototyping machines now have the ability to print multiple materials and even combine these materials in the same job. A 3D model of a robotic hand was designed using Creo Parametric 2.0. Combining "hard" and "soft" materials, the model was printed on the Object Connex350 3D printer with the purpose of resembling as much as possible the human appearance and mobility of a real hand while needing no assembly. After printing the prototype, strings where installed as actuators to test mobility. Based on printing materials, the manufacturing cost of the hand was $167, significantly lower than other robotic hands without the actuators since they have more complex assembly processes.

  14. In vivo assessment of magnesium status in human body using accelerator-based neutron activation measurement of hands: A pilot study

    International Nuclear Information System (INIS)

    Aslam; Pejovic-Milic, A.; McNeill, F. E.; Byun, S. H.; Prestwich, W. V.; Chettle, D. R.

    2008-01-01

    Magnesium (Mg) is an element essential for many enzymatic reactions in the human body. Various human and animal studies suggest that changes in Mg status are linked to diseases such as cardiac arrhythmia, coronary heart disease, hypertension, premenstrual syndrome, and diabetes mellitus. Thus, knowledge of Mg levels in the human body is needed. A direct measurement of human blood serum, which contains only 0.3% of the total body Mg, is generally used to infer information about the status of Mg in the body. However, in many clinical situations, Mg stored in large levels, for example in bones, muscles, and soft tissues, needs to be monitored either to evaluate the efficacy of a treatment or to study the progression of diseases associated with the deficiency of total body Mg. This work presents a feasibility study of a noninvasive, in vivo neutron activation analysis (IVNAA) technique using the 26 Mg(n,γ) 27 Mg reaction to measure Mg levels in human hands. The technique employs the McMaster University high beam current Tandetron accelerator hand irradiation facility and an array of eight NaI (T1) detectors arranged in a 4π geometry for delayed counting of the 0.844 and 1.014 MeV gamma rays emitted when 27 Mg decays in the irradiated hand. Mg determination in humans using IVNAA of hands has been demonstrated to be feasible, with effective doses as low as one-quarter of those delivered in chest x rays. The overall experimental uncertainty in the measurements is estimated to be approximately 5% (1σ). The results are found to be in the range of the in vitro measurements reported for other cortical bones collected from different sites of the human skeleton, which confirms that this technique mainly provides a measure of the amount of Mg in hand bones. The average concentration of Mg determined in human hands is 10.96±1.25 (±1 SD) mg Mg/g Ca. The coefficient of variation (11%) observed in this study is comparable with or lower than several studies using in vitro

  15. Are human hands and feet affected by climate? A test of Allen's rule.

    Science.gov (United States)

    Betti, Lia; Lycett, Stephen J; von Cramon-Taubadel, Noreen; Pearson, Osbjorn M

    2015-09-01

    In recent years, several studies have shown that populations from cold, high-latitude regions tend to have relatively shorter limbs than populations from tropical regions, with most of the difference due to the relative length of the zeugopods (i.e., radius, ulna, tibia, fibula). This pattern has been explained either as the consequence of long-term climatic selection or of phenotypic plasticity, with temperature having a direct effect on bone growth during development. The aims of this study were to test whether this pattern of intra-limb proportions extended to the bones of the hands and feet, and to determine whether the pattern remained significant after taking into account the effects of neutral evolutionary processes related to population history. Measurements of the limb bones, including the first metatarsal and metacarpal, were collected for 393 individuals from 10 globally distributed human populations. The relationship between intra-limb indices and minimum temperature was tested using generalized least squares regression, correcting for spatial autocorrelation. The results confirmed previous observations of a temperature-related gradient in intra-limb proportions, even accounting for population history. This pattern extends to the hands, with populations from cold regions displaying a relatively shorter and stockier first metacarpal; however, the first metatarsal appears to be wider but not shorter in cold-adapted populations. The results suggest that climatic adaptation played a role in shaping variation in limb proportions between human populations. The different patterns shown by the hands and feet might be due to the presence of evolutionary constraints on the foot to maintain efficient bipedal locomotion. © 2015 Wiley Periodicals, Inc.

  16. Mental rotation of anthropoid hands: a chronometric study

    Directory of Open Access Journals (Sweden)

    L.G. Gawryszewski

    2007-03-01

    Full Text Available It has been shown that mental rotation of objects and human body parts is processed differently in the human brain. But what about body parts belonging to other primates? Does our brain process this information like any other object or does it instead maximize the structural similarities with our homologous body parts? We tried to answer this question by measuring the manual reaction time (MRT of human participants discriminating the handedness of drawings representing the hands of four anthropoid primates (orangutan, chimpanzee, gorilla, and human. Twenty-four right-handed volunteers (13 males and 11 females were instructed to judge the handedness of a hand drawing in palm view by pressing a left/right key. The orientation of hand drawings varied from 0º (fingers upwards to 90º lateral (fingers pointing away from the midline, 180º (fingers downwards and 90º medial (finger towards the midline. The results showed an effect of rotation angle (F(3, 69 = 19.57, P < 0.001, but not of hand identity, on MRTs. Moreover, for all hand drawings, a medial rotation elicited shorter MRTs than a lateral rotation (960 and 1169 ms, respectively, P < 0.05. This result has been previously observed for drawings of the human hand and related to biomechanical constraints of movement performance. Our findings indicate that anthropoid hands are essentially equivalent stimuli for handedness recognition. Since the task involves mentally simulating the posture and rotation of the hands, we wondered if "mirror neurons" could be involved in establishing the motor equivalence between the stimuli and the participants' own hands.

  17. The application of force-sensing resistor sensors for measuring forces developed by the human hand.

    Science.gov (United States)

    Nikonovas, A; Harrison, A J L; Hoult, S; Sammut, D

    2004-01-01

    Most attempts to measure forces developed by the human hand have been implemented by placing force sensors on the object of interaction. Other researchers have placed sensors just on the subject's fingertips. In this paper, a system is described that measures forces over the entire hand using thin-film sensors and associated electronics. This system was developed by the authors and is able to obtain force readings from up to 60 thin-film sensors at rates of up to 400 samples/s per sensor. The sensors can be placed anywhere on the palm and/or fingers of the hand. The sensor readings, together with a video stream containing information about hand posture, are logged into a portable computer using a multiplexer, analogue-to-digital converter and software developed for the purpose. The system has been successfully used to measure forces involved in a range of everyday tasks such as driving a vehicle, lifting saucepans and hitting a golf ball. In the latter case, results are compared with those from an instrumented golf club. Future applications include the assessment of hand strength following disease, trauma or surgery, and to enable quantitative ergonomic investigations.

  18. Monte Carlo simulation of neutron irradiation facility developed for accelerator based in vivo neutron activation measurements in human hand bones

    International Nuclear Information System (INIS)

    Aslam; Prestwich, W.V.; McNeill, F.E.; Waker, A.J.

    2006-01-01

    The neutron irradiation facility developed at the McMaster University 3 MV Van de Graaff accelerator was employed to assess in vivo elemental content of aluminum and manganese in human hands. These measurements were carried out to monitor the long-term exposure of these potentially toxic trace elements through hand bone levels. The dose equivalent delivered to a patient during irradiation procedure is the limiting factor for IVNAA measurements. This article describes a method to estimate the average radiation dose equivalent delivered to the patient's hand during irradiation. The computational method described in this work augments the dose measurements carried out earlier [Arnold et al., 2002. Med. Phys. 29(11), 2718-2724]. This method employs the Monte Carlo simulation of hand irradiation facility using MCNP4B. Based on the estimated dose equivalents received by the patient hand, the proposed irradiation procedure for the IVNAA measurement of manganese in human hands [Arnold et al., 2002. Med. Phys. 29(11), 2718-2724] with normal (1 ppm) and elevated manganese content can be carried out with a reasonably low dose of 31 mSv to the hand. Sixty-three percent of the total dose equivalent is delivered by non-useful fast group (>10 keV); the filtration of this neutron group from the beam will further decrease the dose equivalent to the patient's hand

  19. Quantification of manganese in human hand bones: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Aslam; Pejovic-Milic, A; Chettle, D R; McNeill, F E [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, ON, L8S 4K1 (Canada)], E-mail: aslamib@mcmaster.ca

    2008-08-07

    Manganese is both an essential element to human health and also toxic when humans are exposed to excessive levels, particularly by means of inhalation. Biological monitoring of manganese exposure is problematic. It is subject to homeostasis; levels in blood (or serum/plasma) reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive technique for measurement of manganese stored in bone, using in vivo neutron activation analysis. Following preliminary feasibility studies, the technique has been enhanced by two significant infrastructure advances. A specially designed irradiation facility serves to maximize the activation of manganese with respect to the dose of ionizing radiation. Secondly, an array of eight NaI(Tl) crystals provides a detection system with very close to 4{pi} geometry. This feasibility study, using neutron activation analysis to measure manganese in the bones of the hand, takes two features into account. Firstly, there is considerable magnesium present in the bone and this produces a spectral interference with the manganese. The {sup 26}Mg(n,{gamma}){sup 27}Mg reaction produces {gamma}-rays of 0.843 MeV from the decay of {sup 27}Mg, which interfere with the 0.847 MeV {gamma}-rays from the decay of {sup 56}Mn, produced by the {sup 55}Mn(n,{gamma}){sup 56}Mn reaction. Secondly, this work provides estimates of the levels of manganese to be expected in referent subjects. A revised estimate has been made from the most recent literature to explore the potential of the technique as a suitable means of screening patients and people exposed to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. This report presents the enhancements to the neutron activation system, by which manganese can be measured, which resulted in a detection

  20. Quantification of manganese in human hand bones: a feasibility study

    International Nuclear Information System (INIS)

    Aslam; Pejovic-Milic, A; Chettle, D R; McNeill, F E

    2008-01-01

    Manganese is both an essential element to human health and also toxic when humans are exposed to excessive levels, particularly by means of inhalation. Biological monitoring of manganese exposure is problematic. It is subject to homeostasis; levels in blood (or serum/plasma) reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive technique for measurement of manganese stored in bone, using in vivo neutron activation analysis. Following preliminary feasibility studies, the technique has been enhanced by two significant infrastructure advances. A specially designed irradiation facility serves to maximize the activation of manganese with respect to the dose of ionizing radiation. Secondly, an array of eight NaI(Tl) crystals provides a detection system with very close to 4π geometry. This feasibility study, using neutron activation analysis to measure manganese in the bones of the hand, takes two features into account. Firstly, there is considerable magnesium present in the bone and this produces a spectral interference with the manganese. The 26 Mg(n,γ) 27 Mg reaction produces γ-rays of 0.843 MeV from the decay of 27 Mg, which interfere with the 0.847 MeV γ-rays from the decay of 56 Mn, produced by the 55 Mn(n,γ) 56 Mn reaction. Secondly, this work provides estimates of the levels of manganese to be expected in referent subjects. A revised estimate has been made from the most recent literature to explore the potential of the technique as a suitable means of screening patients and people exposed to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. This report presents the enhancements to the neutron activation system, by which manganese can be measured, which resulted in a detection limit in the hand of human subjects of 1.6

  1. A Hands-On Classroom Simulation to Demonstrate Concepts in Enzyme Kinetics

    Science.gov (United States)

    Junker, Matthew

    2010-01-01

    A classroom exercise is described to introduce enzyme kinetics in an undergraduate biochemistry or chemistry course. The exercise is a simulation in which a student acts as an enzyme that "catalyzes" the unscrewing of a nut from a bolt. With other students assisting, the student enzyme carries out reactions with bolt-nut substrates under different…

  2. Modeling of scale-dependent bacterial growth by chemical kinetics approach.

    Science.gov (United States)

    Martínez, Haydee; Sánchez, Joaquín; Cruz, José-Manuel; Ayala, Guadalupe; Rivera, Marco; Buhse, Thomas

    2014-01-01

    We applied the so-called chemical kinetics approach to complex bacterial growth patterns that were dependent on the liquid-surface-area-to-volume ratio (SA/V) of the bacterial cultures. The kinetic modeling was based on current experimental knowledge in terms of autocatalytic bacterial growth, its inhibition by the metabolite CO2, and the relief of inhibition through the physical escape of the inhibitor. The model quantitatively reproduces kinetic data of SA/V-dependent bacterial growth and can discriminate between differences in the growth dynamics of enteropathogenic E. coli, E. coli JM83, and Salmonella typhimurium on one hand and Vibrio cholerae on the other hand. Furthermore, the data fitting procedures allowed predictions about the velocities of the involved key processes and the potential behavior in an open-flow bacterial chemostat, revealing an oscillatory approach to the stationary states.

  3. Modeling of Scale-Dependent Bacterial Growth by Chemical Kinetics Approach

    Directory of Open Access Journals (Sweden)

    Haydee Martínez

    2014-01-01

    Full Text Available We applied the so-called chemical kinetics approach to complex bacterial growth patterns that were dependent on the liquid-surface-area-to-volume ratio (SA/V of the bacterial cultures. The kinetic modeling was based on current experimental knowledge in terms of autocatalytic bacterial growth, its inhibition by the metabolite CO2, and the relief of inhibition through the physical escape of the inhibitor. The model quantitatively reproduces kinetic data of SA/V-dependent bacterial growth and can discriminate between differences in the growth dynamics of enteropathogenic E. coli, E. coli  JM83, and Salmonella typhimurium on one hand and Vibrio cholerae on the other hand. Furthermore, the data fitting procedures allowed predictions about the velocities of the involved key processes and the potential behavior in an open-flow bacterial chemostat, revealing an oscillatory approach to the stationary states.

  4. Heparin kinetics

    International Nuclear Information System (INIS)

    Swart, C.A.M. de.

    1983-01-01

    The author has studied the kinetics of heparin and heparin fractions after intravenous administration in humans and in this thesis the results of this study are reported. Basic knowledge about the physico-chemical properties of heparin and its interactions with proteins resulting in anticoagulant and lipolytic effects are discussed in a review (chapter II), which also comprises some clinical aspects of heparin therapy. In chapter III the kinetics of the anticoagulant effect are described after intravenous administration of five commercial heparin preparations. A mathematical model is presented that fits best to these kinetics. The kinetics of the anticoagulant and lipolytic effects after intravenous injection of various 35 S-radiolabelled heparin fractions and their relationship with the disappearance of the radiolabel are described in chapter IV. Chapter V gives a description of the kinetics of two radiolabels after injection of in vitro formed complexes consisting of purified, 125 I-radiolabelled antithrombin III and various 35 S-radiolabelled heparin fractions. (Auth.)

  5. Domestic dogs' (Canis familiaris) choices in reference to information provided by human and artificial hands.

    Science.gov (United States)

    Kundey, Shannon M A; Delise, Justin; De Los Reyes, Andres; Ford, Kathy; Starnes, Blair; Dennen, Weston

    2014-03-01

    Even young humans show sensitivity to the accuracy and reliability of informants' reports. Children are selective in soliciting information and in accepting claims. Recent research has also investigated domestic dogs' (Canis familiaris) sensitivity to agreement among human informants. Such research utilizing a common human pointing gesture to which dogs are sensitive in a food retrieval paradigm suggests that dogs might choose among informants according to the number of points exhibited, rather than the number of individuals indicating a particular location. Here, we further investigated dogs' use of information from human informants using a stationary pointing gesture, as well as the conditions under which dogs would utilize a stationary point. First, we explored whether the number of points or the number of individuals more strongly influenced dogs' choices. To this end, dogs encountered a choice situation in which the number of points exhibited toward a particular location and the number of individuals exhibiting those points conflicted. Results indicated that dogs chose in accordance with the number of points exhibited toward a particular location. In a second experiment, we explored the possibility that previously learned associations drove dogs' responses to the stationary pointing gesture. In this experiment, dogs encountered a choice situation in which artificial hands exhibited a stationary pointing gesture toward or away from choice locations in the absence of humans. Dogs chose the location to which the artificial hand pointed. These results are consistent with the notion that dogs may respond to a human pointing gesture due to their past-learning history.

  6. Acute HBV infection in humanized chimeric mice has multiphasic viral kinetics.

    Science.gov (United States)

    Ishida, Yuji; Chung, Tje Lin; Imamura, Michio; Hiraga, Nobuhiko; Sen, Suranjana; Yokomichi, Hiroshi; Tateno, Chise; Canini, Laetitia; Perelson, Alan S; Uprichard, Susan L; Dahari, Harel; Chayama, Kazuaki

    2018-03-23

    Chimeric uPA/SCID mice reconstituted with humanized livers are useful for studying HBV infection in the absence of an adaptive immune response. However, the detailed characterization of HBV infection kinetics necessary to enable in-depth mechanistic studies in this novel in vivo HBV infection model is lacking. To characterize HBV kinetics post-inoculation (p.i.) to steady state, 42 mice were inoculated with HBV. Serum HBV DNA was frequently measured from 1 minute to 63 days p.i. Total intrahepatic HBV DNA, HBV cccDNA, and HBV RNA was measured in a subset of mice at 2, 4, 6, 10, and 13 weeks p.i. HBV half-life (t 1/2 ) was estimated using a linear mixed-effects model. During the first 6 h p.i. serum HBV declined in repopulated uPA/SCID mice with a t 1/2 =62 min [95%CI=59-67min]. Thereafter, viral decline slowed followed by a 2 day lower plateau. Subsequent viral amplification was multiphasic with an initial mean doubling time of t 2 =8±3 h followed by an interim plateau before prolonged amplification (t 2 =2±0.5 days) to a final HBV steady state of 9.3±0.3 log copies/ml. Serum HBV and intrahepatic HBV DNA were positively correlated (R 2 =0.98). HBV infection in uPA/SCID chimeric mice is highly dynamic despite the absence of an adaptive immune response. The serum HBV t 1/2 in humanized uPA/SCID mice was estimated to be ∼1 h regardless of inoculum size. The HBV acute infection kinetics presented here is an important step in characterizing this experimental model system so that it can be effectively used to elucidate the dynamics of the HBV lifecycle and thus possibly reveal effective antiviral drug targets. This article is protected by copyright. All rights reserved. © 2018 by the American Association for the Study of Liver Diseases.

  7. Chain length distribution and kinetic characteristics of an enzymatically produced polymer

    NARCIS (Netherlands)

    Mulders, K.J.M.; Beeftink, H.H.

    2013-01-01

    Non-processive enzymatic polymerization leads to a distribution of polymer chain lengths. A polymerization model was developed to investigate the relation between the extent of this distribution on one hand, and the polymerization start conditions and reaction kinetics on the other hand. The model

  8. SPONGE ROBOTIC HAND DESIGN FOR PROSTHESES

    OpenAIRE

    Mine Seçkin

    2016-01-01

    In this study robotic hands and fingers’ materials are investigated from past to present and a sponge robotic hand is designed for biomedical applications. Emergence and necessity of soft robotic technology are explained and description of soft robot is made. Because of the importance of hand in a person’s body, researchers have dealt with robotic hand prostheses for many centuries and developed many hand types. To mimic the best for the human limbs, softness of the hand is one of the importa...

  9. Impact of human milk pasteurization on the kinetics of peptide release during in vitro dynamic term newborn digestion.

    Science.gov (United States)

    Deglaire, Amélie; De Oliveira, Samira C; Jardin, Julien; Briard-Bion, Valérie; Emily, Mathieu; Ménard, Olivia; Bourlieu, Claire; Dupont, Didier

    2016-07-01

    Holder pasteurization (62.5°C, 30 min) ensures sanitary quality of donor's human milk but also denatures beneficial proteins. Understanding whether this further impacts the kinetics of peptide release during gastrointestinal digestion of human milk was the aim of the present paper. Mature raw (RHM) or pasteurized (PHM) human milk were digested (RHM, n = 2; PHM, n = 3) by an in vitro dynamic system (term stage). Label-free quantitative peptidomics was performed on milk and digesta (ten time points). Ascending hierarchical clustering was conducted on "Pasteurization × Digestion time" interaction coefficients. Preproteolysis occurred in human milk (159 unique peptides; RHM: 91, PHM: 151), mostly on β-casein (88% of the endogenous peptides). The predicted cleavage number increased with pasteurization, potentially through plasmin activation (plasmin cleavages: RHM, 53; PHM, 76). During digestion, eight clusters resumed 1054 peptides from RHM and PHM, originating for 49% of them from β-casein. For seven clusters (57% of peptides), the kinetics of peptide release differed between RHM and PHM. The parent protein was significantly linked to the clustering (p-value = 1.4 E-09), with β-casein and lactoferrin associated to clusters in an opposite manner. Pasteurization impacted selectively gastric and intestinal kinetics of peptide release in term newborns, which may have further nutritional consequences. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. FUSION OF SENDAI VIRUS WITH HUMAN HL-60 AND CEM CELLS - DIFFERENT KINETICS OF FUSION FOR 2 ISOLATES

    NARCIS (Netherlands)

    DELIMA, MCP; NIR, S; FLASHER, D; KLAPPE, K; HOEKSTRA, D; DUZGUNES, N

    1991-01-01

    The kinetics of fusion of Sendai virus (Z strain) with the human promyelocytic leukemia cell line HL-60, and the human T lymphocytic leukemia cell line CEM was investigated. Fusion was monitored by fluorescence dequenching of octadecylrhodamine (R-18) incorporated in the viral membrane. For one

  11. Multiscale Convolutional Neural Networks for Hand Detection

    Directory of Open Access Journals (Sweden)

    Shiyang Yan

    2017-01-01

    Full Text Available Unconstrained hand detection in still images plays an important role in many hand-related vision problems, for example, hand tracking, gesture analysis, human action recognition and human-machine interaction, and sign language recognition. Although hand detection has been extensively studied for decades, it is still a challenging task with many problems to be tackled. The contributing factors for this complexity include heavy occlusion, low resolution, varying illumination conditions, different hand gestures, and the complex interactions between hands and objects or other hands. In this paper, we propose a multiscale deep learning model for unconstrained hand detection in still images. Deep learning models, and deep convolutional neural networks (CNNs in particular, have achieved state-of-the-art performances in many vision benchmarks. Developed from the region-based CNN (R-CNN model, we propose a hand detection scheme based on candidate regions generated by a generic region proposal algorithm, followed by multiscale information fusion from the popular VGG16 model. Two benchmark datasets were applied to validate the proposed method, namely, the Oxford Hand Detection Dataset and the VIVA Hand Detection Challenge. We achieved state-of-the-art results on the Oxford Hand Detection Dataset and had satisfactory performance in the VIVA Hand Detection Challenge.

  12. Morphology of muscle attachment sites in the modern human hand does not reflect muscle architecture.

    Science.gov (United States)

    Williams-Hatala, E M; Hatala, K G; Hiles, S; Rabey, K N

    2016-06-23

    Muscle attachment sites (entheses) on dry bones are regularly used by paleontologists to infer soft tissue anatomy and to reconstruct behaviors of extinct organisms. This method is commonly applied to fossil hominin hand bones to assess their abilities to participate in Paleolithic stone tool behaviors. Little is known, however, about how or even whether muscle anatomy and activity regimes influence the morphologies of their entheses, especially in the hand. Using the opponens muscles from a sample of modern humans, we tested the hypothesis that aspects of hand muscle architecture that are known to be influenced by behavior correlate with the size and shape of their associated entheses. Results show no consistent relationships between these behaviorally-influenced aspects of muscle architecture and entheseal morphology. Consequently, it is likely premature to infer patterns of behavior, such as stone tool making in fossil hominins, from these same entheses.

  13. The importance of inclusion of kinetic information in the extrapolation of high-to-low concentrations for human limit setting.

    NARCIS (Netherlands)

    Geraets, Liesbeth; Zeilmaker, Marco J; Bos, Peter M J

    2018-01-01

    Human health risk assessment of inhalation exposures generally includes a high-to-low concentration extrapolation. Although this is a common step in human risk assessment, it introduces various uncertainties. One of these uncertainties is related to the toxicokinetics. Many kinetic processes such as

  14. Monosynaptic Ia projections from intrinsic hand muscles to forearm motoneurones in humans.

    Science.gov (United States)

    Marchand-Pauvert, V; Nicolas, G; Pierrot-Deseilligny, E

    2000-05-15

    Heteronymous Ia excitatory projections from intrinsic hand muscles to human forearm motoneurones (MNs) were investigated. Changes in firing probability of single motor units (MUs) in the flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), flexor digitorum superficialis (FDS), extensor carpi radialis (ECR), extensor carpi ulnaris (ECU) and extensor digitorum communis (EDC) were studied after electrical stimuli were applied to the median and ulnar nerve at wrist level and to the corresponding homonymous nerve at elbow level. Homonymous facilitation, occurring at the same latency as the H reflex, and therefore attributed to monosynaptic Ia EPSPs, was found in all the sampled units. In many MUs an early facilitation was also evoked by heteronymous low-threshold afferents from intrinsic hand muscles. The low threshold (between 0.5 and 0.6 times motor threshold (MT)) and the inability of a pure cutaneous stimulation to reproduce this effect indicate that it is due to stimulation of group I muscle afferents. Evidence for a similar central delay (monosynaptic) in heteronymous as in homonymous pathways was accepted when the difference in latencies of the homonymous and heteronymous peaks did not differ from the estimated supplementary afferent conduction time from wrist to elbow level by more than 0.5 ms (conduction velocity in the fastest Ia afferents between wrist and elbow levels being equal to 69 m s-1). A statistically significant heteronymous monosynaptic Ia excitation from intrinsic hand muscles supplied by both median and ulnar nerves was found in MUs belonging to all forearm motor nuclei tested (although not in ECU MUs after ulnar stimulation). It was, however, more often found in flexors than in extensors, in wrist than in finger muscles and in muscles operating in the radial than in the ulnar side. It is argued that the connections of Ia afferents from intrinsic hand muscles to forearm MNs, which are stronger and more widely distributed than in the cat

  15. Establishment of one-axis vibration test system for measurement of biodynamic response of human hand-arm system.

    Science.gov (United States)

    Shibata, Nobuyuki; Hosoya, Naoki; Maeda, Setsuo

    2008-12-01

    Prolonged exposure to hand-arm vibration (HAV) due to use of hand-held power tools leads to an increased occurrence of symptoms of disorders in the vascular, neurological, and osteo-articular systems of the upper limbs called hand-arm vibration syndrome (HAVS). Biodynamic responses of the hand-arm system to vibration can be suggestive parameters that give us better assessment of exposure to HAV and fundamental data for design of low-vibration-exposure power tools. Recently, a single axis hand-arm vibration system has been installed in the Japan National Institute of Occupational Safety and Health (NIOSH). The aims of this study were to obtain the fundamental dynamic characteristics of an instrumented handle and to validate the performance and measurement accuracy of the system applied to dynamic response measurement. A pseudo-random vibration signal with a frequency range of 5-1,250 Hz and a power spectrum density of 1.0 (m/s2)2/Hz was used in this study. First the dynamic response of the instrumented handle without any weight was measured. After this measurement, the dynamic response measurement of the handle with weights mounted on the handle was performed. The apparent mass of a weight itself was obtained by using the mass cancellation method. The mass of the measuring cap on the instrumented handle was well compensated by using the mass cancellation method. Based on the 10% error tolerance, this handle can reliably measure the dynamic response represented by an apparent mass with a minimum weight of 2.0 g in a frequency range of 10.0 to 1,000 Hz. A marked increase in the AM magnitude of the weights of 15 g and 20 g in frequency ranges greater than 800 Hz is attributed not to the fundamental resonance frequency of the handle with weights, but to the fixation of the weight to the measuring cap. In this aspect, the peak of the AM magnitude can be reduced and hence should not be an obstacle to the biodynamic response measurement of the human hand-arm system. On the

  16. Development of a parametric kinematic model of the human hand and a novel robotic exoskeleton.

    Science.gov (United States)

    Burton, T M W; Vaidyanathan, R; Burgess, S C; Turton, A J; Melhuish, C

    2011-01-01

    This paper reports the integration of a kinematic model of the human hand during cylindrical grasping, with specific focus on the accurate mapping of thumb movement during grasping motions, and a novel, multi-degree-of-freedom assistive exoskeleton mechanism based on this model. The model includes thumb maximum hyper-extension for grasping large objects (~> 50 mm). The exoskeleton includes a novel four-bar mechanism designed to reproduce natural thumb opposition and a novel synchro-motion pulley mechanism for coordinated finger motion. A computer aided design environment is used to allow the exoskeleton to be rapidly customized to the hand dimensions of a specific patient. Trials comparing the kinematic model to observed data of hand movement show the model to be capable of mapping thumb and finger joint flexion angles during grasping motions. Simulations show the exoskeleton to be capable of reproducing the complex motion of the thumb to oppose the fingers during cylindrical and pinch grip motions. © 2011 IEEE

  17. The SmartHand transradial prosthesis

    Directory of Open Access Journals (Sweden)

    Carrozza Maria Chiara

    2011-05-01

    Full Text Available Abstract Background Prosthetic components and control interfaces for upper limb amputees have barely changed in the past 40 years. Many transradial prostheses have been developed in the past, nonetheless most of them would be inappropriate if/when a large bandwidth human-machine interface for control and perception would be available, due to either their limited (or inexistent sensorization or limited dexterity. SmartHand tackles this issue as is meant to be clinically experimented in amputees employing different neuro-interfaces, in order to investigate their effectiveness. This paper presents the design and on bench evaluation of the SmartHand. Methods SmartHand design was bio-inspired in terms of its physical appearance, kinematics, sensorization, and its multilevel control system. Underactuated fingers and differential mechanisms were designed and exploited in order to fit all mechatronic components in the size and weight of a natural human hand. Its sensory system was designed with the aim of delivering significant afferent information to the user through adequate interfaces. Results SmartHand is a five fingered self-contained robotic hand, with 16 degrees of freedom, actuated by 4 motors. It integrates a bio-inspired sensory system composed of 40 proprioceptive and exteroceptive sensors and a customized embedded controller both employed for implementing automatic grasp control and for potentially delivering sensory feedback to the amputee. It is able to perform everyday grasps, count and independently point the index. The weight (530 g and speed (closing time: 1.5 seconds are comparable to actual commercial prostheses. It is able to lift a 10 kg suitcase; slippage tests showed that within particular friction and geometric conditions the hand is able to stably grasp up to 3.6 kg cylindrical objects. Conclusions Due to its unique embedded features and human-size, the SmartHand holds the promise to be experimentally fitted on transradial

  18. Mechanism-based Inhibitors of the Human Sirtuin 5 Deacylase: Structure-Activity Relationship, Biostructural, and Kinetic Insight

    DEFF Research Database (Denmark)

    Rajabi, Nima; Auth, Marina; Troelsen, Kathrin Rentzius

    2017-01-01

    to date. We provide rationalization of the mode of binding by solving co-crystal structures of selected inhibitors in complex with both human and zebrafish SIRT5, which provide insight for future optimization of inhibitors with more "drug-like" properties. Importantly, enzyme kinetic evaluation revealed...

  19. Development of a Combined In Vitro Physiologically Based Kinetic (PBK) and Monte Carlo Modelling Approach to Predict Interindividual Human Variation in Phenol-Induced Developmental Toxicity.

    Science.gov (United States)

    Strikwold, Marije; Spenkelink, Bert; Woutersen, Ruud A; Rietjens, Ivonne M C M; Punt, Ans

    2017-06-01

    With our recently developed in vitro physiologically based kinetic (PBK) modelling approach, we could extrapolate in vitro toxicity data to human toxicity values applying PBK-based reverse dosimetry. Ideally information on kinetic differences among human individuals within a population should be considered. In the present study, we demonstrated a modelling approach that integrated in vitro toxicity data, PBK modelling and Monte Carlo simulations to obtain insight in interindividual human kinetic variation and derive chemical specific adjustment factors (CSAFs) for phenol-induced developmental toxicity. The present study revealed that UGT1A6 is the primary enzyme responsible for the glucuronidation of phenol in humans followed by UGT1A9. Monte Carlo simulations were performed taking into account interindividual variation in glucuronidation by these specific UGTs and in the oral absorption coefficient. Linking Monte Carlo simulations with PBK modelling, population variability in the maximum plasma concentration of phenol for the human population could be predicted. This approach provided a CSAF for interindividual variation of 2.0 which covers the 99th percentile of the population, which is lower than the default safety factor of 3.16 for interindividual human kinetic differences. Dividing the dose-response curve data obtained with in vitro PBK-based reverse dosimetry, with the CSAF provided a dose-response curve that reflects the consequences of the interindividual variability in phenol kinetics for the developmental toxicity of phenol. The strength of the presented approach is that it provides insight in the effect of interindividual variation in kinetics for phenol-induced developmental toxicity, based on only in vitro and in silico testing. © The Author 2017. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Design and validation of a morphing myoelectric hand posture controller based on principal component analysis of human grasping.

    Science.gov (United States)

    Segil, Jacob L; Weir, Richard F ff

    2014-03-01

    An ideal myoelectric prosthetic hand should have the ability to continuously morph between any posture like an anatomical hand. This paper describes the design and validation of a morphing myoelectric hand controller based on principal component analysis of human grasping. The controller commands continuously morphing hand postures including functional grasps using between two and four surface electromyography (EMG) electrodes pairs. Four unique maps were developed to transform the EMG control signals in the principal component domain. A preliminary validation experiment was performed by 10 nonamputee subjects to determine the map with highest performance. The subjects used the myoelectric controller to morph a virtual hand between functional grasps in a series of randomized trials. The number of joints controlled accurately was evaluated to characterize the performance of each map. Additional metrics were studied including completion rate, time to completion, and path efficiency. The highest performing map controlled over 13 out of 15 joints accurately.

  1. Measuring hand hygiene compliance rates at hospital entrances.

    Science.gov (United States)

    Vaidotas, Marina; Yokota, Paula Kiyomi Onaga; Marra, Alexandre R; Camargo, Thiago Zinsly Sampaio; Victor, Elivane da Silva; Gysi, Deisy Morselli; Leal, Flavio; Santos, Oscar Fernando Pavão dos; Edmond, Michael B

    2015-07-01

    Despite the importance of hand hygiene in the health care setting, there are no studies evaluating hand hygiene compliance at hospital entrances. The study was prospectively performed over a 33-week period from March 30, 2014-November 15, 2014, to evaluate hand hygiene compliance in 2 hospital reception areas. We compared electronic handwash counters with the application of radiofrequency identification (GOJO SMARTLINK) (electronic observer) that counts each activation of alcohol gel dispensers to direct observation (human observer) via remote review of video surveillance. We found low hand hygiene compliance rates of 2.2% (99/4,412) and 1.7% (140/8,277), respectively, at reception areas A and D, detected by direct observation. Using the electronic observer, we measured rates of 17% (15,624/91,724) and 7.1% (51,605/730,357) at reception areas A and D, respectively. For the overall time period of simultaneous electronic and human observation, the human observer captured 1% of the hand hygiene episodes detected by the electronic observer. Our study showed very low hand hygiene compliance in hospital reception areas, and we found an electronic hand hygiene system to be a useful method to monitor hand hygiene compliance. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  2. Cytomegalovirus survival and transferability and the effectiveness of common hand-washing agents against cytomegalovirus on live human hands.

    Science.gov (United States)

    Stowell, Jennifer D; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L; Dollard, Sheila C; Bialek, Stephanie R; Cannon, Michael J; Schmid, D Scott

    2014-01-01

    Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 10(5) infectious particles/ml. Samples from hands or surfaces (points between 0 and 15 min) were placed in culture and observed for at least 2 weeks. Samples were also tested using CMV real-time PCR. After application of bacteria to the hands, viable CMV was recovered from 17/20 swabs at 0 min, 18/20 swabs at 1 min, 5/20 swabs at 5 min, and 4/20 swabs at 15 min. After transfer, duration of survival was at least 15 min on plastic (1/2 swabs), 5 min on crackers and glass (3/4 swabs), and 1 min or less on metal and cloth (3/4 swabs); no viable virus was collected from wood, rubber, or hands. After cleansing, no viable virus was recovered using water (0/22), plain soap (0/20), antibacterial soap (0/20), or sanitizer (0/22). Viable CMV was recovered from 4/20 hands 10 min after diaper wipe cleansing. CMV remains viable on hands for sufficient times to allow transmission. CMV may be transferred to surfaces with reduced viability. Hand-cleansing methods were effective at eliminating viable CMV from hands.

  3. [The hands--means of expression for relationship, creativity and coping].

    Science.gov (United States)

    Kinzl, J F

    2008-02-01

    The hand is an important active sense organ. Hands help human beings to organise and change the environment, and most developments of mankind would not have been possible without hands. The hands also made a great contribution to the high degree of brain development. The hands are an important characteristic feature of identity and identification and sign of individuality as well. Human hands have a long history as an instrument of social interaction and as an object of social attention. The language of hands offers many kinds of expression and gestures help to underline the words.

  4. The impact of whole human blood on the kinetic inertness of platinum(iv) prodrugs - an HPLC-ICP-MS study.

    Science.gov (United States)

    Theiner, Sarah; Grabarics, Márkó; Galvez, Luis; Varbanov, Hristo P; Sommerfeld, Nadine S; Galanski, Markus; Keppler, Bernhard K; Koellensperger, Gunda

    2018-04-17

    The potential advantage of platinum(iv) complexes as alternatives to classical platinum(ii)-based drugs relies on their kinetic stability in the body before reaching the tumor site and on their activation by reduction inside cancer cells. In this study, an analytical workflow has been developed to investigate the reductive biotransformation and kinetic inertness of platinum(iv) prodrugs comprising different ligand coordination spheres (respectively, lipophilicity and redox behavior) in whole human blood. The distribution of platinum(iv) complexes in blood pellets and plasma was determined by inductively coupled plasma-mass spectrometry (ICP-MS) after microwave digestion. An analytical approach based on reversed-phase (RP)-ICP-MS was used to monitor the parent compound and the formation of metabolites using two different extraction procedures. The ligand coordination sphere of the platinum(iv) complexes had a significant impact on their accumulation in red blood cells and on their degree of kinetic inertness in whole human blood. The most lipophilic platinum(iv) compound featuring equatorial chlorido ligands showed a pronounced penetration into blood cells and a rapid reductive biotransformation. In contrast, the more hydrophilic platinum(iv) complexes with a carboplatin- and oxaliplatin-core exerted kinetic inertness on a pharmacologically relevant time scale with notable amounts of the compound accumulated in the plasma fraction.

  5. Humans can integrate feedback of discrete events in their sensorimotor control of a robotic hand.

    Science.gov (United States)

    Cipriani, Christian; Segil, Jacob L; Clemente, Francesco; ff Weir, Richard F; Edin, Benoni

    2014-11-01

    Providing functionally effective sensory feedback to users of prosthetics is a largely unsolved challenge. Traditional solutions require high band-widths for providing feedback for the control of manipulation and yet have been largely unsuccessful. In this study, we have explored a strategy that relies on temporally discrete sensory feedback that is technically simple to provide. According to the Discrete Event-driven Sensory feedback Control (DESC) policy, motor tasks in humans are organized in phases delimited by means of sensory encoded discrete mechanical events. To explore the applicability of DESC for control, we designed a paradigm in which healthy humans operated an artificial robot hand to lift and replace an instrumented object, a task that can readily be learned and mastered under visual control. Assuming that the central nervous system of humans naturally organizes motor tasks based on a strategy akin to DESC, we delivered short-lasting vibrotactile feedback related to events that are known to forcefully affect progression of the grasp-lift-and-hold task. After training, we determined whether the artificial feedback had been integrated with the sensorimotor control by introducing short delays and we indeed observed that the participants significantly delayed subsequent phases of the task. This study thus gives support to the DESC policy hypothesis. Moreover, it demonstrates that humans can integrate temporally discrete sensory feedback while controlling an artificial hand and invites further studies in which inexpensive, noninvasive technology could be used in clever ways to provide physiologically appropriate sensory feedback in upper limb prosthetics with much lower band-width requirements than with traditional solutions.

  6. Kinetic analysis of the cannabinoid-1 receptor PET tracer [18F]MK-9470 in human brain

    International Nuclear Information System (INIS)

    Sanabria-Bohorquez, Sandra Marina; Hamill, Terence G.; Burns, H.D.; Goffin, Karolien; Laere, Koen van; Lepeleire, Inge de; Bormans, Guy

    2010-01-01

    Quantitative imaging of the type 1 cannabinoid receptor (CB1R) opens perspectives for many neurological and psychiatric disorders. We characterized the kinetics and reproducibility of the CB1R tracer [ 18 F]MK-9470 in human brain. [ 18 F]MK-9470 data were analysed using reversible models and the distribution volume V T and V ND k 3 (V ND k 3 = K 1 k 2 ) were estimated. Tracer binding was also evaluated using irreversible kinetics and the irreversible uptake constant K i and fractional uptake rate (FUR) were estimated. The effect of blood flow on these parameters was evaluated. Additionally, the possibility of determining the tracer plasma kinetics using a reduced number of blood samples was also examined. A reversible two-tissue compartment model using a global k 4 value was necessary to describe brain kinetics. Both V T and V ND k 3 were estimated satisfactorily and their test-retest variability was between 10% and 30%. Irreversible methods adequately described brain kinetics and FUR values were equivalent to K i . The linear relationship between K i and V ND k 3 demonstrated that K i or FUR and thus the simple measure of tracer brain uptake provide CB1R availability information. The test-retest variability of K i and FUR was 18 F]MK-9470 specific binding can be accurately determined using FUR values requiring a short scan 90 to 120 min after tracer administration. Our results suggest that [ 18 F]MK-9470 plasma kinetics can be assessed using a few venous samples. (orig.)

  7. Predictability of hand skill and cognitive abilities from craniofacial width in right- and left-handed men and women: relation of skeletal structure to cerebral function

    OpenAIRE

    Dayi, Ertunc; Okuyan, Mukadder; Tan, Uner

    2002-01-01

    Recently, a family of homeobox genes involved in brain and craniofacial development was identified. In light of this genetic background, we hypothesized that some functional characteristics of human brain (hand skill, cognition) may be linked to some structural characteristics of human skull (e.g. craniofacial width) in humans. Hand preference was assessed by the Oldfield`s Handedness Questionaire. Hand skill was measured by Peg Moving Task. Face width was measured from the anteroposterior ce...

  8. Augmented robotic device for EVA hand manoeuvres

    Science.gov (United States)

    Matheson, Eloise; Brooker, Graham

    2012-12-01

    During extravehicular activities (EVAs), pressurised space suits can lead to difficulties in performing hand manoeuvres and fatigue. This is often the cause of EVAs being terminated early, or taking longer to complete. Assistive robotic gloves can be used to augment the natural motion of a human hand, meaning work can be carried out more efficiently with less stress to the astronaut. Lightweight and low profile solutions must be found in order for the assistive robotic glove to be easily integrated with a space suit pressure garment. Pneumatic muscle actuators combined with force sensors are one such solution. These actuators are extremely light, yet can output high forces using pressurised gases as the actuation drive. Their movement is omnidirectional, so when combined with a flexible exoskeleton that itself provides a degree of freedom of movement, individual fingers can be controlled during flexion and extension. This setup allows actuators and other hardware to be stored remotely on the user's body, resulting in the least possible mass being supported by the hand. Two prototype gloves have been developed at the University of Sydney; prototype I using a fibreglass exoskeleton to provide flexion force, and prototype II using torsion springs to achieve the same result. The gloves have been designed to increase the ease of human movements, rather than to add unnatural ability to the hand. A state space control algorithm has been developed to ensure that human initiated movements are recognised, and calibration methods have been implemented to accommodate the different characteristics of each wearer's hands. For this calibration technique, it was necessary to take into account the natural tremors of the human hand which may have otherwise initiated unexpected control signals. Prototype I was able to actuate the user's hand in 1 degree of freedom (DOF) from full flexion to partial extension, and prototype II actuated a user's finger in 2 DOF with forces achieved

  9. Is Hand Selection Modulated by Cognitive-perceptual Load?

    Science.gov (United States)

    Liang, Jiali; Wilkinson, Krista; Sainburg, Robert L

    2018-01-15

    Previous studies proposed that selecting which hand to use for a reaching task appears to be modulated by a factor described as "task difficulty". However, what features of a task might contribute to greater or lesser "difficulty" in the context of hand selection decisions has yet to be determined. There has been evidence that biomechanical and kinematic factors such as movement smoothness and work can predict patterns of selection across the workspace, suggesting a role of predictive cost analysis in hand-selection. We hypothesize that this type of prediction for hand-selection should recruit substantial cognitive resources and thus should be influenced by cognitive-perceptual loading. We test this hypothesis by assessing the role of cognitive-perceptual loading on hand selection decisions, using a visual search task that presents different levels of difficulty (cognitive-perceptual load), as established in previous studies on overall response time and efficiency of visual search. Although the data are necessarily preliminary due to small sample size, our data suggested an influence of cognitive-perceptual load on hand selection, such that the dominant hand was selected more frequently as cognitive load increased. Interestingly, cognitive-perceptual loading also increased cross-midline reaches with both hands. Because crossing midline is more costly in terms of kinematic and kinetic factors, our findings suggest that cognitive processes are normally engaged to avoid costly actions, and that the choice not-to-cross midline requires cognitive resources. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  10. Low-cost design and fabrication of an anthropomorphic robotic hand.

    Science.gov (United States)

    Junaid, Ali Bin; Tahir, Sanan; Rasheed, Tahir; Ahmed, Sharjeel; Sohail, Mehreen; Afzal, Muhammad Raheel; Ali, Muzaffar; Kim, Yoonsoo

    2014-10-01

    Human hand signifies a magnificent and challenging example for scientists and engineers trying to replicate its complex structure and functionality. This paper proposes a bio-mechatronic approach for the design of an anthropomorphic artificial hand capable of performing basic human hand motions with fundamental gripping functionality. The dexterity of the artificial hand is exhibited by imitating the natural motion of the human fingers. Imitation is produced according to the data acquired from the flex sensors attached to the human fingers. In order to have proper gripping, closed-loop control is implemented using the tactile sensors. Feedback for the closed-loop control is provided by force sensing resistors (FSRs), attached on the fingertips of the robotic hand. These sensors also enable handling of fragile objects. The mathematical model is derived using forward kinematics and also simulated on MATLAB to ascertain the position of robotic fingers in 3D space.

  11. Learning the Fundamentals of Kinetics and Reaction Engineering with the Catalytic Oxidation of Methane

    Science.gov (United States)

    Cybulskis, Viktor J.; Smeltz, Andrew D.; Zvinevich, Yury; Gounder, Rajamani; Delgass, W. Nicholas; Ribeiro, Fabio H.

    2016-01-01

    Understanding catalytic chemistry, collecting and interpreting kinetic data, and operating chemical reactors are critical skills for chemical engineers. This laboratory experiment provides students with a hands-on supplement to a course in chemical kinetics and reaction engineering. The oxidation of methane with a palladium catalyst supported on…

  12. Kinetic chain abnormalities in the athletic shoulder.

    Science.gov (United States)

    Sciascia, Aaron; Thigpen, Charles; Namdari, Surena; Baldwin, Keith

    2012-03-01

    Overhead activities require the shoulder to be exposed to and sustain repetitive loads. The segmental activation of the body's links, known as the kinetic chain, allows this to occur effectively. Proper muscle activation is achieved through generation of energy from the central segment or core, which then transfers the energy to the terminal links of the shoulder, elbow, and hand. The kinetic chain is best characterized by 3 components: optimized anatomy, reproducible efficient motor patterns, and the sequential generation of forces. However, tissue injury and anatomic deficits such as weakness and/or tightness in the leg, pelvic core, or scapular musculature can lead to overuse shoulder injuries. These injuries can be prevented and maladaptations can be detected with a thorough understanding of biomechanics of the kinetic chain as it relates to overhead activity.

  13. A novel cortical target to enhance hand motor output in humans with spinal cord injury.

    Science.gov (United States)

    Long, Jinyi; Federico, Paolo; Perez, Monica A

    2017-06-01

    A main goal of rehabilitation strategies in humans with spinal cord injury is to strengthen transmission in spared neural networks. Although neuromodulatory strategies have targeted different sites within the central nervous system to restore motor function following spinal cord injury, the role of cortical targets remain poorly understood. Here, we use 180 pairs of transcranial magnetic stimulation for ∼30 min over the hand representation of the motor cortex at an interstimulus interval mimicking the rhythmicity of descending late indirect (I) waves in corticospinal neurons (4.3 ms; I-wave protocol) or at an interstimulus interval in-between I-waves (3.5 ms; control protocol) on separate days in a randomized order. Late I-waves are thought to arise from trans-synaptic cortical inputs and have a crucial role in the recruitment of spinal motor neurons following spinal cord injury. Motor evoked potentials elicited by transcranial magnetic stimulation, paired-pulse intracortical inhibition, spinal motor neuron excitability (F-waves), index finger abduction force and electromyographic activity as well as a hand dexterity task were measured before and after both protocols in 15 individuals with chronic incomplete cervical spinal cord injury and 17 uninjured participants. We found that motor evoked potentials size increased in spinal cord injury and uninjured participants after the I-wave but not the control protocol for ∼30 to 60 min after the stimulation. Intracortical inhibition decreased and F-wave amplitude and persistence increased after the I-wave but not the control protocol, suggesting that cortical and subcortical networks contributed to changes in corticospinal excitability. Importantly, hand motor output and hand dexterity increased in individuals with spinal cord injury after the I-wave protocol. These results provide the first evidence that late synaptic input to corticospinal neurons may represent a novel therapeutic target for improving motor function

  14. Robot hand tackles jobs in hazardous areas

    International Nuclear Information System (INIS)

    Simms, Mark; Crowder, Richard.

    1989-01-01

    A robot hand and arm designed to mimic the operation of its human counterpart, developed at the University of Southampton for use in a standard industrial glovebox, is described. It was specifically designed for use in a radioactive environment moving high dosage components around. As dosage limits go down, there is a legal requirement to remove people from that environment. The nine-axis arm is for use in a glove designed for a human hand. Drive for the motors used to power the hand is from three-phase MOSFET inventor cards, the switching pattern controlled by the Hall effect communication sensors integral to each motor. The computer software for the arm allows the hand to be positioned using a joystick on a control box, with three levels of command for grip, pinch and touch. (author)

  15. Integrated Analysis of Contractile Kinetics, Force Generation, and Electrical Activity in Single Human Stem Cell-Derived Cardiomyocytes

    Directory of Open Access Journals (Sweden)

    Jan David Kijlstra

    2015-12-01

    Full Text Available The quantitative analysis of cardiomyocyte function is essential for stem cell-based approaches for the in vitro study of human cardiac physiology and pathophysiology. We present a method to comprehensively assess the function of single human pluripotent stem cell-derived cardiomyocyte (hPSC-CMs through simultaneous quantitative analysis of contraction kinetics, force generation, and electrical activity. We demonstrate that statistical analysis of movies of contracting hPSC-CMs can be used to quantify changes in cellular morphology over time and compute contractile kinetics. Using a biomechanical model that incorporates substrate stiffness, we calculate cardiomyocyte force generation at single-cell resolution and validate this approach with conventional traction force microscopy. The addition of fluorescent calcium indicators or membrane potential dyes allows the simultaneous analysis of contractility and calcium handling or action potential morphology. Accordingly, our approach has the potential for broad application in the study of cardiac disease, drug discovery, and cardiotoxicity screening.

  16. Viral kinetics of Enterovirus 71 in human abdomyosarcoma cells

    Science.gov (United States)

    Lu, Jing; He, Ya-Qing; Yi, Li-Na; Zan, Hong; Kung, Hsiang-Fu; He, Ming-Liang

    2011-01-01

    AIM: To characterise the viral kinetics of enterovirus 71 (EV71). METHODS: In this study, human rhabdomyosarcoma (RD) cells were infected with EV71 at different multiplicity of infection (MOI). After infection, the cytopathic effect (CPE) was monitored and recorded using a phase contrast microscope associated with a CCD camera at different time points post viral infection (0, 6, 12, 24 h post infection). Cell growth and viability were measured by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay in both EV71 infected and mock infected cells at each time point. EV71 replication kinetics in RD cells was determined by measuring the total intracellular viral RNA with real-time reverse-transcription polymerase chain reaction (qRT-PCR). Also, the intracellular and extracellular virion RNA was isolated and quantified at different time points to analyze the viral package and secretion. The expression of viral protein was determined by analyze the levels of viral structure protein VP1 with Western blotting. RESULTS: EV71 infection induced a significant CPE as early as 6 h post infection (p.i.) in both RD cells infected with high ratio of virus (MOI 10) and low ratio of virus (MOI 1). In EV71 infected cells, the cell growth was inhibited and the number of viable cells was rapidly decreased in the later phase of infection. EV71 virions were uncoated immediately after entry. The intracellular viral RNA began to increase at as early as 3 h p.i. and the exponential increase was found between 3 h to 6 h p.i. in both infected groups. For viral structure protein synthesis, results from western-blot showed that intracellular viral protein VP1 could not be detected until 6 h p.i. in the cells infected at either MOI 1 or MOI 10; and reached the peak at 9 h p.i. in the cells infected with EV71 at both MOI 1 and MOI 10. Simultaneously, the viral package and secretion were also actively processed as the virus underwent rapid replication. The viral package kinetics

  17. Position calibration of a 3-DOF hand-controller with hybrid structure

    Science.gov (United States)

    Zhu, Chengcheng; Song, Aiguo

    2017-09-01

    A hand-controller is a human-robot interactive device, which measures the 3-DOF (Degree of Freedom) position of the human hand and sends it as a command to control robot movement. The device also receives 3-DOF force feedback from the robot and applies it to the human hand. Thus, the precision of 3-DOF position measurements is a key performance factor for hand-controllers. However, when using a hybrid type 3-DOF hand controller, various errors occur and are considered originating from machining and assembly variations within the device. This paper presents a calibration method to improve the position tracking accuracy of hybrid type hand-controllers by determining the actual size of the hand-controller parts. By re-measuring and re-calibrating this kind of hand-controller, the actual size of the key parts that cause errors is determined. Modifying the formula parameters with the actual sizes, which are obtained in the calibrating process, improves the end position tracking accuracy of the device.

  18. Unconstrained and contactless hand geometry biometrics.

    Science.gov (United States)

    de-Santos-Sierra, Alberto; Sánchez-Ávila, Carmen; Del Pozo, Gonzalo Bailador; Guerra-Casanova, Javier

    2011-01-01

    This paper presents a hand biometric system for contact-less, platform-free scenarios, proposing innovative methods in feature extraction, template creation and template matching. The evaluation of the proposed method considers both the use of three contact-less publicly available hand databases, and the comparison of the performance to two competitive pattern recognition techniques existing in literature: namely support vector machines (SVM) and k-nearest neighbour (k-NN). Results highlight the fact that the proposed method outcomes existing approaches in literature in terms of computational cost, accuracy in human identification, number of extracted features and number of samples for template creation. The proposed method is a suitable solution for human identification in contact-less scenarios based on hand biometrics, providing a feasible solution to devices with limited hardware requirements like mobile devices.

  19. Unconstrained and Contactless Hand Geometry Biometrics

    Directory of Open Access Journals (Sweden)

    Carmen Sánchez-Ávila

    2011-10-01

    Full Text Available This paper presents a hand biometric system for contact-less, platform-free scenarios, proposing innovative methods in feature extraction, template creation and template matching. The evaluation of the proposed method considers both the use of three contact-less publicly available hand databases, and the comparison of the performance to two competitive pattern recognition techniques existing in literature: namely Support Vector Machines (SVM and k-Nearest Neighbour (k-NN. Results highlight the fact that the proposed method outcomes existing approaches in literature in terms of computational cost, accuracy in human identification, number of extracted features and number of samples for template creation. The proposed method is a suitable solution for human identification in contact-less scenarios based on hand biometrics, providing a feasible solution to devices with limited hardware requirements like mobile devices.

  20. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands

    Science.gov (United States)

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M. L.; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2016-07-01

    The term 'synergy' - from the Greek synergia - means 'working together'. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project ;The Hand Embodied; (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies.

  1. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands

    Science.gov (United States)

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M.L.; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2017-01-01

    The term ‘synergy’ – from the Greek synergia – means ‘working together’. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project “The Hand Embodied” (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies. PMID:26923030

  2. Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands.

    Science.gov (United States)

    Santello, Marco; Bianchi, Matteo; Gabiccini, Marco; Ricciardi, Emiliano; Salvietti, Gionata; Prattichizzo, Domenico; Ernst, Marc; Moscatelli, Alessandro; Jörntell, Henrik; Kappers, Astrid M L; Kyriakopoulos, Kostas; Albu-Schäffer, Alin; Castellini, Claudio; Bicchi, Antonio

    2016-07-01

    The term 'synergy' - from the Greek synergia - means 'working together'. The concept of multiple elements working together towards a common goal has been extensively used in neuroscience to develop theoretical frameworks, experimental approaches, and analytical techniques to understand neural control of movement, and for applications for neuro-rehabilitation. In the past decade, roboticists have successfully applied the framework of synergies to create novel design and control concepts for artificial hands, i.e., robotic hands and prostheses. At the same time, robotic research on the sensorimotor integration underlying the control and sensing of artificial hands has inspired new research approaches in neuroscience, and has provided useful instruments for novel experiments. The ambitious goal of integrating expertise and research approaches in robotics and neuroscience to study the properties and applications of the concept of synergies is generating a number of multidisciplinary cooperative projects, among which the recently finished 4-year European project "The Hand Embodied" (THE). This paper reviews the main insights provided by this framework. Specifically, we provide an overview of neuroscientific bases of hand synergies and introduce how robotics has leveraged the insights from neuroscience for innovative design in hardware and controllers for biomedical engineering applications, including myoelectric hand prostheses, devices for haptics research, and wearable sensing of human hand kinematics. The review also emphasizes how this multidisciplinary collaboration has generated new ways to conceptualize a synergy-based approach for robotics, and provides guidelines and principles for analyzing human behavior and synthesizing artificial robotic systems based on a theory of synergies. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Photoacoustic Analysis of the Penetration Kinetics of Cordia verbenacea DC in Human Skin

    Science.gov (United States)

    Carvalho, S. S.; Barja, P. R.

    2012-11-01

    Phonophoresis consists of the utilization of ultrasound radiation associated to pharmacological agents in order to enhance transdermal penetration of applied drugs. It is a widely employed resource in physiotherapy practice, normally associated with anti-inflammatory drugs, such as Acheflan. This drug was developed in Brazil from the essential oil of Cordia verbenacea DC, a native plant of the Brazilian southern coast. In previous studies, the photoacoustic (PA) technique proved effective in the study of the penetration kinetics of topically applied products and in the evaluation of drug delivery after phonophoresis application. The present work aimed to evaluate the penetration kinetics of Acheflan in human skin, employing in vivo PA measurements after massage application or phonophoresis application. Ten volunteers (aged between 18 and 30 years) took part in the study. Time evolution of the PA signal was fitted to a Boltzmann curve, S-shaped. After statistical analysis, PA measurements have shown drug penetration for both application forms, but drug delivery was more evident after phonophoresis application, with a characteristic penetration time of less than 15 min for the stratum corneum.

  4. Effects of vehicle on the uptake and elimination kinetics of capsaicinoids in human skin in vivo

    International Nuclear Information System (INIS)

    Pershing, Lynn K.; Reilly, Christopher A.; Corlett, Judy L.; Crouch, Dennis J.

    2004-01-01

    While the physiologic and molecular effects of capsaicinoids have been extensively studied in various model systems by a variety of administration routes, little is known about the uptake and elimination kinetic profiles in human skin following topical exposure. The present study evaluated the uptake and elimination kinetics of capsaicinoids in human stratum corneum following a single topical exposure to 3% solutions containing 55% capsaicin, 35% dihydrocapsaicin, and 10% other analogues prepared in three vehicles: mineral oil (MO), propylene glycol (PG), and isopropyl alcohol (IPA). Capsaicinoid solutions were evaluated simultaneously in a random application pattern on the volar forearms of 12 subjects using a small, single 150-μg dose. Capsaicin and dihydrocapsaicin were recovered from human skin using commercial adhesive discs to harvest stratum corneum from treated sites. Capsaicinoids were extracted from the stratum corneum-adhesive discs and quantified by liquid chromatography/mass spectroscopy (LC/MS). Both capsaicinoids were detected in stratum corneum 1 min after application with all vehicles and achieved a pseudo-steady state shortly thereafter. IPA delivered three times greater capsaicin and dihydrocapsaicin into the human stratum corneum than PG or MO at all time points investigated. The C max of capsaicin in IPA, PG, and MO was 16.1, 6.2, and 6.5 μg, respectively. The dihydrocapsaicin content was 60% of capsaicin with all vehicles. The estimated T half of capsaicin and dihydrocapsaicin in the three vehicles was similar (24 h). Thus, maximal cutaneous capsaicinoid concentrations were achieved quickly in the human stratum corneum and were concentration and vehicle dependent. In contrast, capsaicinoid half-life was long and vehicle independent

  5. RELATIVE EFFICACY OF HUMAN SOCIAL INTERACTION AND FOOD AS REINFORCERS FOR DOMESTIC DOGS AND HAND-REARED WOLVES

    Science.gov (United States)

    Feuerbacher, Erica N; Wynne, Clive D. L

    2012-01-01

    Despite the intimate relationship dogs share with humans in Western society, we know relatively little about the variables that produce and maintain dog social behavior towards humans. One possibility is that human social interaction is itself a reinforcer for dog behavior. As an initial assessment of the variables that might maintain dog social behavior, we compared the relative efficacy of brief human social interaction to a small piece of food as a reinforcer for an arbitrary response (nose touch). We investigated this in three populations of canids: shelter dogs, owned dogs, and hand-reared wolves. Across all three canid populations, brief social interaction was a relatively ineffective reinforcer compared to food for most canids, producing lower responding and longer latencies than food. PMID:22851794

  6. Frontoparietal Tracts Linked to Lateralized Hand Preference and Manual Specialization.

    Science.gov (United States)

    Howells, Henrietta; Thiebaut de Schotten, Michel; Dell'Acqua, Flavio; Beyh, Ahmad; Zappalà, Giuseppe; Leslie, Anoushka; Simmons, Andrew; Murphy, Declan G; Catani, Marco

    2018-04-21

    Humans show a preference for using the right hand over the left for tasks and activities of everyday life. While experimental work in non-human primates has identified the neural systems responsible for reaching and grasping, the neural basis of lateralized motor behavior in humans remains elusive. The advent of diffusion imaging tractography for studying connectional anatomy in the living human brain provides the possibility of understanding the relationship between hemispheric asymmetry, hand preference, and manual specialization. In this study, diffusion tractography was used to demonstrate an interaction between hand preference and the asymmetry of frontoparietal tracts, specifically the dorsal branch of the superior longitudinal fasciculus, responsible for visuospatial integration and motor planning. This is in contrast to the corticospinal tract and the superior cerebellar peduncle, for which asymmetry was not related to hand preference. Asymmetry of the dorsal frontoparietal tract was also highly correlated with the degree of lateralization in tasks requiring visuospatial integration and fine motor control. These results suggest a common anatomical substrate for hand preference and lateralized manual specialization in frontoparietal tracts important for visuomotor processing.

  7. Reactivation of organophosphate-inhibited human, Cynomolgus monkey, swine and guinea pig acetylcholinesterase by MMB-4: A modified kinetic approach

    International Nuclear Information System (INIS)

    Worek, Franz; Wille, Timo; Aurbek, Nadine; Eyer, Peter; Thiermann, Horst

    2010-01-01

    Treatment of poisoning by highly toxic organophosphorus compounds (OP, nerve agents) is a continuous challenge. Standard treatment with atropine and a clinically used oxime, obidoxime or pralidoxime is inadequate against various nerve agents. For ethical reasons testing of oxime efficacy has to be performed in animals. Now, it was tempting to investigate the reactivation kinetics of MMB-4, a candidate oxime to replace pralidoxime, with nerve agent-inhibited acetylcholinesterase (AChE) from human and animal origin in order to provide a kinetic basis for the proper assessment of in vivo data. By applying a modified kinetic approach, allowing the use of necessary high MMB-4 concentrations, it was possible to determine the reactivation constants with sarin-, cyclosarin-, VX-, VR- and tabun-inhibited AChE. MMB-4 exhibited a high reactivity and low affinity towards OP-inhibited AChE, except of tabun-inhibited enzyme where MMB-4 had an extremely low reactivity. Species differences between human and animal AChE were low (Cynomolgus) to moderate (swine, guinea pig). Due to the high reactivity of MMB-4 a rapid reactivation of inhibited AChE can be anticipated at adequate oxime concentrations which are substantially higher compared to HI-6. Additional studies are necessary to determine the in vivo toxicity, tolerability and pharmacokinetics of MMB-4 in humans in order to enable a proper assessment of the value of this oxime as an antidote against nerve agent poisoning.

  8. Reactivation of organophosphate-inhibited human, Cynomolgus monkey, swine and guinea pig acetylcholinesterase by MMB-4: a modified kinetic approach.

    Science.gov (United States)

    Worek, Franz; Wille, Timo; Aurbek, Nadine; Eyer, Peter; Thiermann, Horst

    2010-12-15

    Treatment of poisoning by highly toxic organophosphorus compounds (OP, nerve agents) is a continuous challenge. Standard treatment with atropine and a clinically used oxime, obidoxime or pralidoxime is inadequate against various nerve agents. For ethical reasons testing of oxime efficacy has to be performed in animals. Now, it was tempting to investigate the reactivation kinetics of MMB-4, a candidate oxime to replace pralidoxime, with nerve agent-inhibited acetylcholinesterase (AChE) from human and animal origin in order to provide a kinetic basis for the proper assessment of in vivo data. By applying a modified kinetic approach, allowing the use of necessary high MMB-4 concentrations, it was possible to determine the reactivation constants with sarin-, cyclosarin-, VX-, VR- and tabun-inhibited AChE. MMB-4 exhibited a high reactivity and low affinity towards OP-inhibited AChE, except of tabun-inhibited enzyme where MMB-4 had an extremely low reactivity. Species differences between human and animal AChE were low (Cynomolgus) to moderate (swine, guinea pig). Due to the high reactivity of MMB-4 a rapid reactivation of inhibited AChE can be anticipated at adequate oxime concentrations which are substantially higher compared to HI-6. Additional studies are necessary to determine the in vivo toxicity, tolerability and pharmacokinetics of MMB-4 in humans in order to enable a proper assessment of the value of this oxime as an antidote against nerve agent poisoning. Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Reorganization of the Human Somatosensory Cortex in Hand Dystonia

    Directory of Open Access Journals (Sweden)

    Maria Jose Catalan

    2012-05-01

    Full Text Available Background and Purpose: Abnormalities of finger representations in the somatosensory cortex have been identified in patients with focal hand dystonia. Measuring blood flow with positron emission tomography (PET can be use to demonstrate functional localization of receptive fields. Methods: A vibratory stimulus was applied to the right thumb and little finger of six healthy volunteers and six patients with focal hand dystonia to map their receptive fields using H215O PET. Results: The cortical finger representations in the primary somatosensory cortex were closer to each other in patients than in normal subjects. No abnormalities were found in secondary somatosensory cortex, but the somatotopy there is less well distinguished. Conclusions: These data confirm prior electrophysiological and functional neuroimaging observations showing abnormalities of finger representations in somatosensory cortex of patients with focal hand dystonia.

  10. Coordination of hand shape.

    Science.gov (United States)

    Pesyna, Colin; Pundi, Krishna; Flanders, Martha

    2011-03-09

    The neural control of hand movement involves coordination of the sensory, motor, and memory systems. Recent studies have documented the motor coordinates for hand shape, but less is known about the corresponding patterns of somatosensory activity. To initiate this line of investigation, the present study characterized the sense of hand shape by evaluating the influence of differences in the amount of grasping or twisting force, and differences in forearm orientation. Human subjects were asked to use the left hand to report the perceived shape of the right hand. In the first experiment, six commonly grasped items were arranged on the table in front of the subject: bottle, doorknob, egg, notebook, carton, and pan. With eyes closed, subjects used the right hand to lightly touch, forcefully support, or imagine holding each object, while 15 joint angles were measured in each hand with a pair of wired gloves. The forces introduced by supporting or twisting did not influence the perceptual report of hand shape, but for most objects, the report was distorted in a consistent manner by differences in forearm orientation. Subjects appeared to adjust the intrinsic joint angles of the left hand, as well as the left wrist posture, so as to maintain the imagined object in its proper spatial orientation. In a second experiment, this result was largely replicated with unfamiliar objects. Thus, somatosensory and motor information appear to be coordinated in an object-based, spatial-coordinate system, sensitive to orientation relative to gravitational forces, but invariant to grasp forcefulness.

  11. Double nerve intraneural interface implant on a human amputee for robotic hand control.

    Science.gov (United States)

    Rossini, Paolo M; Micera, Silvestro; Benvenuto, Antonella; Carpaneto, Jacopo; Cavallo, Giuseppe; Citi, Luca; Cipriani, Christian; Denaro, Luca; Denaro, Vincenzo; Di Pino, Giovanni; Ferreri, Florinda; Guglielmelli, Eugenio; Hoffmann, Klaus-Peter; Raspopovic, Stanisa; Rigosa, Jacopo; Rossini, Luca; Tombini, Mario; Dario, Paolo

    2010-05-01

    The principle underlying this project is that, despite nervous reorganization following upper limb amputation, original pathways and CNS relays partially maintain their function and can be exploited for interfacing prostheses. Aim of this study is to evaluate a novel peripheral intraneural multielectrode for multi-movement prosthesis control and for sensory feed-back, while assessing cortical reorganization following the re-acquired stream of data. Four intrafascicular longitudinal flexible multielectrodes (tf-LIFE4) were implanted in the median and ulnar nerves of an amputee; they reliably recorded output signals for 4 weeks. Artificial intelligence classifiers were used off-line to analyse LIFE signals recorded during three distinct hand movements under voluntary order. Real-time control of motor output was achieved for the three actions. When applied off-line artificial intelligence reached >85% real-time correct classification of trials. Moreover, different types of current stimulation were determined to allow reproducible and localized hand/fingers sensations. Cortical organization was observed via TMS in parallel with partial resolution of symptoms due to the phantom-limb syndrome (PLS). tf-LIFE4s recorded output signals in human nerves for 4 weeks, though the efficacy of sensory stimulation decayed after 10 days. Recording from a number of fibres permitted a high percentage of distinct actions to be classified correctly. Reversal of plastic changes and alleviation of PLS represent corollary findings of potential therapeutic benefit. This study represents a breakthrough in robotic hand use in amputees. Copyright 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Growth and production kinetics of human x mouse and mouse hybridoma cells at reduced temperature and serum content.

    Science.gov (United States)

    Borth, N; Heider, R; Assadian, A; Katinger, H

    1992-09-01

    The growth and production kinetics of a mouse hybridoma cell line and a human-mouse heterohybridoma were analyzed under conditions of reduced temperature and serum content. The mouse hybridoma P24 had a constant cell specific production rate and RNA content, while the heterohybridoma 3D6-LC4 showed growth associated production kinetics and an increased RNA content at higher growth rates. This behaviour of 3D6-LC4 cells can be explained by the unusual cell cycle kinetics of this line, which can be arrested in any phase under growth limiting conditions, so that a low growth rate does not result in a greater portion of high producing G1-phase cells. Substrate limitation changes the cell cycle distribution of this cell line to a greater extent than low temperature or serum content, which indicates that this stress factor exerts a greater physiological control than assumed.

  13. Acute alcohol intoxication in a child following ingestion of an ethyl-alcohol-based hand sanitizer.

    Science.gov (United States)

    Hertzog, James H; Radwick, Allison

    2015-07-01

    While uncommon, ingestion of ethanol-based hand sanitizers by children may be associated with significant intoxication. We report the case of a 7-year-old with acute alcohol intoxication following hand sanitizer ingestion. Alcohol elimination in this patient followed zero-order kinetics with a clearance rate of 22.5 mg/kg/h, consistent with the limited pharmacokinetic information available for children who experience alcohol intoxication from more traditional sources.

  14. 2D Hand Tracking Based on Flocking with Obstacle Avoidance

    Directory of Open Access Journals (Sweden)

    Zihong Chen

    2014-02-01

    Full Text Available Hand gesture-based interaction provides a natural and powerful means for human-computer interaction. It is also a good interface for human-robot interaction. However, most of the existing proposals are likely to fail when they meet some skin-coloured objects, especially the face region. In this paper, we present a novel hand tracking method which can track the features of the hand based on the obstacle avoidance flocking behaviour model to overcome skin-coloured distractions. It allows features to be split into two groups under severe distractions and merge later. The experiment results show that our method can track the hand in a cluttered background or when passing the face, while the Flocking of Features (FoF and the Mean Shift Embedded Particle Filter (MSEPF methods may fail. These results suggest that our method has better performance in comparison with the previous methods. It may therefore be helpful to promote the use of the hand gesture-based human-robot interaction method.

  15. Convergence of human brain mapping tools: neuronavigated TMS parameters and fMRI activity in the hand motor area.

    Science.gov (United States)

    Sarfeld, Anna-Sophia; Diekhoff, Svenja; Wang, Ling E; Liuzzi, Gianpiero; Uludağ, Kamil; Eickhoff, Simon B; Fink, Gereon R; Grefkes, Christian

    2012-05-01

    Functional magnetic resonance imaging (fMRI) and transcranial magnetic stimulation (TMS) are well-established tools for investigating the human motor system in-vivo. We here studied the relationship between movement-related fMRI signal changes in the primary motor cortex (M1) and electrophysiological properties of the hand motor area assessed with neuronavigated TMS in 17 healthy subjects. The voxel showing the highest task-related BOLD response in the left hand motor area during right hand movements was identified for each individual subject. This fMRI peak voxel in M1 served as spatial target for coil positioning during neuronavigated TMS. We performed correlation analyses between TMS parameters, BOLD signal estimates and effective connectivity parameters of M1 assessed with dynamic causal modeling (DCM). The results showed a negative correlation between the movement-related BOLD signal in left M1 and resting as well as active motor threshold (MT) obtained for left M1. The DCM analysis revealed that higher excitability of left M1 was associated with a stronger coupling between left supplementary motor area (SMA) and M1. Furthermore, BOLD activity in left M1 correlated with ipsilateral silent period (ISP), i.e. the stronger the task-related BOLD response in left M1, the higher interhemispheric inhibition effects targeting right M1. DCM analyses revealed a positive correlation between the coupling of left SMA with left M1 and the duration of ISP. The data show that TMS parameters assessed for the hand area of M1 do not only reflect the intrinsic properties at the stimulation site but also interactions with remote areas in the human motor system. Copyright © 2011 Wiley-Liss, Inc.

  16. Robotic hand with locking mechanism using TCP muscles for applications in prosthetic hand and humanoids

    Science.gov (United States)

    Saharan, Lokesh; Tadesse, Yonas

    2016-04-01

    This paper presents a biomimetic, lightweight, 3D printed and customizable robotic hand with locking mechanism consisting of Twisted and Coiled Polymer (TCP) muscles based on nylon precursor fibers as artificial muscles. Previously, we have presented a small-sized biomimetic hand using nylon based artificial muscles and fishing line muscles as actuators. The current study focuses on an adult-sized prosthetic hand with improved design and a position/force locking system. Energy efficiency is always a matter of concern to make compact, lightweight, durable and cost effective devices. In natural human hand, if we keep holding objects for long time, we get tired because of continuous use of energy for keeping the fingers in certain positions. Similarly, in prosthetic hands we also need to provide energy continuously to artificial muscles to hold the object for a certain period of time, which is certainly not energy efficient. In this work we, describe the design of the robotic hand and locking mechanism along with the experimental results on the performance of the locking mechanism.

  17. The role of human parietal area 7A as a link between sequencing in hand actions and in overt speech production

    Directory of Open Access Journals (Sweden)

    Stefan eHeim

    2012-12-01

    Full Text Available Research on the evolutionary basis of the human language faculty has proposed the mirror neuron system as a link between motor processing and speech development. Consequently, most work has focussed on the left inferior frontal cortex, in particular Broca's region, and the left inferior parietal cortex. However, the direct link between planning of hand motor and speech actions remains to be elucidated. Thus, the present study investigated whether sequencing of hand motor actions vs. speech motor actions has a common neural denominator. For the hand motor task, 25 subjects performed single, repeated, or sequenced button presses with either the left or right hand. The speech task was in analogy; the same subjects produced the syllable "po" once or repeatedly, or a sequence of different syllables (po-pi-po. Speech motor vs. hand motor effectors resulted in increased perisylvian activation including Broca's region (left area 44 and areas medially adjacent to left area 45. In contrast, common activation for sequenced vs. repeated production of button presses and syllables revealed the effector-independent involvement of left area 7A in the superior parietal lobule (SPL in sequencing. These data demonstrate that sequencing of vocal gestures, an important precondition for ordered utterances and ultimately human speech, shares area 7A, rather than inferior parietal regions, as a common cortical module with hand motor sequencing. Interestingly, area 7A has previously also been shown to be involved in the observation of hand and non-hand actions. In combination with the literature, the present data thus suggest a distinction between area 44, which is specifically recruited for (cognitive aspects of speech, and SPL area 7A for general aspects of motor sequencing. In sum, the study demonstrates a yet little considered role of the superior parietal lobule in the origins of speech, and may be discussed in the light of embodiment of speech and language in the

  18. The influence of speed and grade on wheelchair propulsion hand pattern.

    Science.gov (United States)

    Slowik, Jonathan S; Requejo, Philip S; Mulroy, Sara J; Neptune, Richard R

    2015-11-01

    The hand pattern used during manual wheelchair propulsion (i.e., full-cycle hand path) can provide insight into an individual's propulsion technique. However, previous analyses of hand patterns have been limited by their focus on a single propulsion condition and reliance on subjective qualitative characterization methods. The purpose of this study was to develop a set of objective quantitative parameters to characterize hand patterns and determine the influence of propulsion speed and grade of incline on the patterns preferred by manual wheelchair users. Kinematic and kinetic data were collected from 170 experienced manual wheelchair users on an ergometer during three conditions: level propulsion at their self-selected speed, level propulsion at their fastest comfortable speed and graded propulsion (8%) at their level self-selected speed. Hand patterns were quantified using a set of objective parameters, and differences across conditions were identified. Increased propulsion speed resulted in a shift away from under-rim hand patterns. Increased grade of incline resulted in the hand remaining near the handrim throughout the cycle. Manual wheelchair users change their hand pattern based on task-specific constraints and goals. Further work is needed to investigate how differences between hand patterns influence upper extremity demand and potentially lead to the development of overuse injuries and pain. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Finger tips detection for two handed gesture recognition

    Science.gov (United States)

    Bhuyan, M. K.; Kar, Mithun Kumar; Neog, Debanga Raj

    2011-10-01

    In this paper, a novel algorithm is proposed for fingertips detection in view of two-handed static hand pose recognition. In our method, finger tips of both hands are detected after detecting hand regions by skin color-based segmentation. At first, the face is removed in the image by using Haar classifier and subsequently, the regions corresponding to the gesturing hands are isolated by a region labeling technique. Next, the key geometric features characterizing gesturing hands are extracted for two hands. Finally, for all possible/allowable finger movements, a probabilistic model is developed for pose recognition. Proposed method can be employed in a variety of applications like sign language recognition and human-robot-interactions etc.

  20. Underactuated hands : Fundamentals, performance analysis and design

    NARCIS (Netherlands)

    Kragten, G.A.

    2011-01-01

    There is an emerging need to apply adaptive robotic hands to substitute humans in dangerous, laborious, or monotonous work. The state-of-the-art robotic hands cannot fulfill this need, because they are expensive, hard to control and they consist of many vulnerable motors and sensors. It is aimed to

  1. A Kinetic Study Using Evaporation of Different Types of Hand-Rub Sanitizers

    Science.gov (United States)

    Pinhas, Allan R.

    2010-01-01

    Alcohol-based hand-rub sanitizers are the types of products that hospital professionals use very often. These sanitizers can be classified into two major groups: those that contain a large quantity of thickener, and thus are a gel, and those that contain a small quantity of thickener, and thus remain a liquid. In an effort to create a laboratory…

  2. Development of a prototype over-actuated biomimetic prosthetic hand.

    Directory of Open Access Journals (Sweden)

    Matthew R Williams

    Full Text Available The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  3. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2008-11-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  4. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2006-06-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  5. Non-primary motor areas in the human frontal lobe are connected directly to hand muscles.

    Science.gov (United States)

    Teitti, S; Määttä, S; Säisänen, L; Könönen, M; Vanninen, R; Hannula, H; Mervaala, E; Karhu, J

    2008-04-15

    Structural studies in primates have shown that, in addition to the primary motor cortex (M1), premotor areas are a source of corticospinal tracts. The function of these putative corticospinal neuronal tracts in humans is still unclear. We found frontal non-primary motor areas (NPMAs), which react to targeted non-invasive magnetic pulses and activate peripheral muscles as fast as or even faster than those in M1. Hand muscle movements were observed in all our subjects about 20 ms after transcranial stimulation of the superior frontal gyrus (Brodmann areas 6 and 8). Stimulation of NPMA could activate both proximal and distal upper limb muscles with the same delay as a stimulation of the M1, indicating converging motor representations with direct functional connections to the hand. We suggest that these non-primary cortical motor representations provide additional capacity for the fast execution of movements. Such a capacity may play a role in motor learning and in recovery from motor deficits.

  6. Do right-handed monkeys use the right cheek pouch before the left?

    Directory of Open Access Journals (Sweden)

    Madhur Mangalam

    Full Text Available There can be several factors that are likely to have played a role in the evolution of hand preference in humans and non-human primates, which the existing theories do not consider. There exists a possibility that hand preference in non-human primates evolved from the pre-existing lateralities in more elementary brain functions and behavior, or alternatively, the two coevolved. A basic example can be a hand-mouth command system that could have evolved in the context of ingestion. In the present study, we examined the relationship between lateralities in prehension and mastication processes, that is, hand and cheek pouch usage, in free-ranging bonnet macaques, Macaca radiata. The macaques preferentially used one hand-the 'preferred' hand, to pick up the bananas lying on the ground. Lateralities in hand and cheek pouch usage (for both filling and emptying were positively related with each other, that is, the macaques used the cheek pouch corresponding to the preferred hand predominantly and before the other. Moreover, when the macaques used the non-preferred hand to pick up the bananas, the frequency of contralateral cheek pouch usage was higher than the frequency of ipsilateral cheek pouch usage, that is, the combined structure of hand, mouth, and food did not influence the relationship between laterality in hand usage and laterality in cheek pouch usage. These findings demonstrate laterality in a relatively more involuntary function than those explored previously in any non-human primate species (e.g., facial expressions and manual gestures.

  7. The visual development of hand-centered receptive fields in a neural network model of the primate visual system trained with experimentally recorded human gaze changes.

    Science.gov (United States)

    Galeazzi, Juan M; Navajas, Joaquín; Mender, Bedeho M W; Quian Quiroga, Rodrigo; Minini, Loredana; Stringer, Simon M

    2016-01-01

    Neurons have been found in the primate brain that respond to objects in specific locations in hand-centered coordinates. A key theoretical challenge is to explain how such hand-centered neuronal responses may develop through visual experience. In this paper we show how hand-centered visual receptive fields can develop using an artificial neural network model, VisNet, of the primate visual system when driven by gaze changes recorded from human test subjects as they completed a jigsaw. A camera mounted on the head captured images of the hand and jigsaw, while eye movements were recorded using an eye-tracking device. This combination of data allowed us to reconstruct the retinal images seen as humans undertook the jigsaw task. These retinal images were then fed into the neural network model during self-organization of its synaptic connectivity using a biologically plausible trace learning rule. A trace learning mechanism encourages neurons in the model to learn to respond to input images that tend to occur in close temporal proximity. In the data recorded from human subjects, we found that the participant's gaze often shifted through a sequence of locations around a fixed spatial configuration of the hand and one of the jigsaw pieces. In this case, trace learning should bind these retinal images together onto the same subset of output neurons. The simulation results consequently confirmed that some cells learned to respond selectively to the hand and a jigsaw piece in a fixed spatial configuration across different retinal views.

  8. Kinetics and spectroscopy of low temperature plasmas

    CERN Document Server

    Loureiro, Jorge

    2016-01-01

    This is a comprehensive textbook designed for graduate and advanced undergraduate students. Both authors rely on more than 20 years of teaching experience in renowned Physics Engineering courses to write this book addressing the students’ needs. Kinetics and Spectroscopy of Low Temperature Plasmas derives in a full self-consistent way the electron kinetic theory used to describe low temperature plasmas created in the laboratory with an electrical discharge, and presents the main optical spectroscopic diagnostics used to characterize such plasmas. The chapters with the theoretical contents make use of a deductive approach in which the electron kinetic theory applied to plasmas with basis on the electron Boltzmann equation is derived from the basic concepts of Statistical and Plasma Physics. On the other hand, the main optical spectroscopy diagnostics used to characterize experimentally such plasmas are presented and justified from the point of view of the Atomic and Molecular Physics. Low temperature plasmas...

  9. Kinetic analysis of the cannabinoid-1 receptor PET tracer [{sup 18}F]MK-9470 in human brain

    Energy Technology Data Exchange (ETDEWEB)

    Sanabria-Bohorquez, Sandra Marina; Hamill, Terence G.; Burns, H.D. [Merck Research Laboratories, Imaging, West Point, PA (United States); Goffin, Karolien; Laere, Koen van [University Hospital and K.U. Leuven, Division of Nuclear Medicine, Leuven (Belgium); Lepeleire, Inge de [Merck Research Laboratories, Brussels (Belgium); Bormans, Guy [K.U. Leuven, Laboratory of Radiopharmacy, Leuven (Belgium)

    2010-05-15

    Quantitative imaging of the type 1 cannabinoid receptor (CB1R) opens perspectives for many neurological and psychiatric disorders. We characterized the kinetics and reproducibility of the CB1R tracer [{sup 18}F]MK-9470 in human brain. [{sup 18}F]MK-9470 data were analysed using reversible models and the distribution volume V{sub T} and V{sub ND} k{sub 3} (V{sub ND} k{sub 3} = K{sub 1} k{sub 2}) were estimated. Tracer binding was also evaluated using irreversible kinetics and the irreversible uptake constant K{sub i} and fractional uptake rate (FUR) were estimated. The effect of blood flow on these parameters was evaluated. Additionally, the possibility of determining the tracer plasma kinetics using a reduced number of blood samples was also examined. A reversible two-tissue compartment model using a global k{sub 4} value was necessary to describe brain kinetics. Both V{sub T} and V{sub ND} k{sub 3} were estimated satisfactorily and their test-retest variability was between 10% and 30%. Irreversible methods adequately described brain kinetics and FUR values were equivalent to K{sub i}. The linear relationship between K{sub i} and V{sub ND} k{sub 3} demonstrated that K{sub i} or FUR and thus the simple measure of tracer brain uptake provide CB1R availability information. The test-retest variability of K{sub i} and FUR was <10% and estimates were independent of blood flow. Brain uptake can be used as a receptor availability index, albeit at the expense of potential bias due to between-subject differences in tracer plasma kinetics. [{sup 18}F]MK-9470 specific binding can be accurately determined using FUR values requiring a short scan 90 to 120 min after tracer administration. Our results suggest that [{sup 18}F]MK-9470 plasma kinetics can be assessed using a few venous samples. (orig.)

  10. Hand Grasping Synergies As Biometrics.

    Science.gov (United States)

    Patel, Vrajeshri; Thukral, Poojita; Burns, Martin K; Florescu, Ionut; Chandramouli, Rajarathnam; Vinjamuri, Ramana

    2017-01-01

    Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements). Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic). Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies) from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies-postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  11. Hand Grasping Synergies As Biometrics

    Directory of Open Access Journals (Sweden)

    Ramana Vinjamuri

    2017-05-01

    Full Text Available Recently, the need for more secure identity verification systems has driven researchers to explore other sources of biometrics. This includes iris patterns, palm print, hand geometry, facial recognition, and movement patterns (hand motion, gait, and eye movements. Identity verification systems may benefit from the complexity of human movement that integrates multiple levels of control (neural, muscular, and kinematic. Using principal component analysis, we extracted spatiotemporal hand synergies (movement synergies from an object grasping dataset to explore their use as a potential biometric. These movement synergies are in the form of joint angular velocity profiles of 10 joints. We explored the effect of joint type, digit, number of objects, and grasp type. In its best configuration, movement synergies achieved an equal error rate of 8.19%. While movement synergies can be integrated into an identity verification system with motion capture ability, we also explored a camera-ready version of hand synergies—postural synergies. In this proof of concept system, postural synergies performed well, but only when specific postures were chosen. Based on these results, hand synergies show promise as a potential biometric that can be combined with other hand-based biometrics for improved security.

  12. Kinetics of the urea-induced dissociation of human plasma alpha-2-macroglobulin as measured by small-angle neutron scattering

    DEFF Research Database (Denmark)

    Sjöberg, B.; Pap, S.; Järnberg, S.-E.

    1991-01-01

    The kinetics of the urea-induced dissociation of human plasma alpha-2-macroglobulin into two half-molecular fragments was investigated at 21.0-degrees-C by using small-angle neutron scattering. The relative change in molecular mass that occurs upon dissociation was monitored by recording the forw...

  13. Design and implementation of a dexterous anthropomorphic robotic typing (DART) hand

    International Nuclear Information System (INIS)

    Thayer, Nicholas; Priya, Shashank

    2011-01-01

    This paper focuses on design and implementation of a biomimetic dexterous humanoid hand. Several design rules are proposed to retain human form and functionality in a robotic hand while overcoming the difficultly of actuation within a confined geometry. Size and weight have been optimized in order to achieve human-like performance with the prime objective of typing on a computer keyboard. Each finger has four joints and three degrees of freedom (DOF) while the thumb has an additional degree of freedom necessary for manipulating small objects. The hand consists of 16 servo motors dedicated to finger motion and three motors for wrist motion. A closed-loop kinematic control scheme utilizing the Denavit–Hartenberg convention for spatial joint positioning was implemented. Servo motors housed in the forearm act as an origin for wires to travel to their insertion points in the hand. The dexterity of the DART hand was measured by quantifying functionality and typing speed on a standard keyboard. The typing speed of a single DART hand was found to be 20 words min −1 . In comparison, the average human has a typing speed of 33 words min −1 with two hands

  14. Glutathione reductase: solvent equilibrium and kinetic isotope effects

    International Nuclear Information System (INIS)

    Wong, K.K.; Vanoni, M.A.; Blanchard, J.S.

    1988-01-01

    Glutathione reductase catalyzes the NADPH-dependent reduction of oxidized glutathione (GSSG). The kinetic mechanism is ping-pong, and we have investigated the rate-limiting nature of proton-transfer steps in the reactions catalyzed by the spinach, yeast, and human erythrocyte glutathione reductases using a combination of alternate substrate and solvent kinetic isotope effects. With NADPH or GSSG as the variable substrate, at a fixed, saturating concentration of the other substrate, solvent kinetic isotope effects were observed on V but not V/K. Plots of Vm vs mole fraction of D 2 O (proton inventories) were linear in both cases for the yeast, spinach, and human erythrocyte enzymes. When solvent kinetic isotope effect studies were performed with DTNB instead of GSSG as an alternate substrate, a solvent kinetic isotope effect of 1.0 was observed. Solvent kinetic isotope effect measurements were also performed on the asymmetric disulfides GSSNB and GSSNP by using human erythrocyte glutathione reductase. The Km values for GSSNB and GSSNP were 70 microM and 13 microM, respectively, and V values were 62 and 57% of the one calculated for GSSG, respectively. Both of these substrates yield solvent kinetic isotope effects greater than 1.0 on both V and V/K and linear proton inventories, indicating that a single proton-transfer step is still rate limiting. These data are discussed in relationship to the chemical mechanism of GSSG reduction and the identity of the proton-transfer step whose rate is sensitive to solvent isotopic composition. Finally, the solvent equilibrium isotope effect measured with yeast glutathione reductase is 4.98, which allows us to calculate a fractionation factor for the thiol moiety of GSH of 0.456

  15. Kinetic model for hydroxyapatite precipitation on human enamel surface by electrolytic deposition

    International Nuclear Information System (INIS)

    Lei Caixia; Liao Yingmin; Feng Zude

    2009-01-01

    The electrolytic deposition (ELD) of hydroxyapatite (HAP) coating on human enamel surface for different loading times at varied temperatures (ranging from 37 deg. C to 85 deg. C) and varied current densities (ranging from 0.05 mA cm -2 to 10 mA cm -2 ) was investigated in this study. Thin film x-ray diffraction, Fourier transform infrared and micro-Raman spectra analysis, as well as an environmental scanning electron microscope, were used to characterize the coating. The results showed that only the HAP phase occurred on the enamel surface after ELD experiments. The contents of HAP deposits on the enamel surface linearly changed proportional to the square root of the loading time, which was in good agreement with the kinetic model of ELD of HAP coating based on one-dimensional diffusion. The induction periods were observed on all the regression lines, and the rate of the HAP coating formation on enamel showed a linear relationship with the current density. It was implied that the diffusion process was the rate-determining step in the ELD of the HAP coating on human enamel.

  16. Phenylalanine kinetics in human adipose tissue.

    OpenAIRE

    Coppack, S W; Persson, M; Miles, J M

    1996-01-01

    Very little is known about the regulation of protein metabolism in adipose tissue. In this study systemic, adipose tissue, and forearm phenylalanine kinetics were determined in healthy postabsorptive volunteers before and during a 2-h glucose infusion (7 mg.kg-1.min-1). [3H]Phenylalanine was infused and blood was sampled from a radial artery, a subcutaneous abdominal vein, and a deep forearm vein. Adipose tissue and forearm blood flow were measured with 133Xe and plethysmography, respectively...

  17. The hand: MR imaging with a 4.7-T magnet

    International Nuclear Information System (INIS)

    Wang, P.C.; Archer, A.; Rajan, S.; Carvlin, M.J.; Mun, S.K.; Nelson, M.C.

    1987-01-01

    MR images of normal and pathologic human hands were obtained using a 4.7-T magnet Varian system. Standard spin-echo techniques and inversion-recovery sequences were used to produce both T1- and T2-weighted images. The higher gradient (2 gauss/cm) of the 4.7-T system allows submillimeter resolution. A specially designed surface coil is used to improve the signal-to-noise ratio. The coil is elliptical and measures 3 inches by 4.5 inches. Axial, coronal, and sagittal images were obtained, revealing fine, detailed structures of the human hand. The joint capsule, ligaments and tendons, and vascular structures were clearly visible. The authors will show images of the normal anatomy of the hand, as well as pathologic lesions of inflammatory and crystalline arthropathy. Techniques and special problems of imaging the human hand with a 4.7-T system are discussed

  18. The Marble-Hand Illusion.

    Science.gov (United States)

    Senna, Irene; Maravita, Angelo; Bolognini, Nadia; Parise, Cesare V

    2014-01-01

    Our body is made of flesh and bones. We know it, and in our daily lives all the senses constantly provide converging information about this simple, factual truth. But is this always the case? Here we report a surprising bodily illusion demonstrating that humans rapidly update their assumptions about the material qualities of their body, based on their recent multisensory perceptual experience. To induce a misperception of the material properties of the hand, we repeatedly gently hit participants' hand with a small hammer, while progressively replacing the natural sound of the hammer against the skin with the sound of a hammer hitting a piece of marble. After five minutes, the hand started feeling stiffer, heavier, harder, less sensitive, unnatural, and showed enhanced Galvanic skin response (GSR) to threatening stimuli. Notably, such a change in skin conductivity positively correlated with changes in perceived hand stiffness. Conversely, when hammer hits and impact sounds were temporally uncorrelated, participants did not spontaneously report any changes in the perceived properties of the hand, nor did they show any modulation in GSR. In two further experiments, we ruled out that mere audio-tactile synchrony is the causal factor triggering the illusion, further demonstrating the key role of material information conveyed by impact sounds in modulating the perceived material properties of the hand. This novel bodily illusion, the 'Marble-Hand Illusion', demonstrates that the perceived material of our body, surely the most stable attribute of our bodily self, can be quickly updated through multisensory integration.

  19. Prosthetic hand sensor placement: Analysis of touch perception during the grasp

    Directory of Open Access Journals (Sweden)

    Mirković Bojana

    2014-01-01

    Full Text Available Humans rely on their hands to perform everyday tasks. The hand is used as a tool, but also as the interface to “sense” the world. Current prosthetic hands are based on sophisticated multi-fingered structures, and include many sensors which counterpart natural proprioceptors and exteroceptors. The sensory information is used for control, but not sent to the user of the hand (amputee. Grasping without sensing is not good enough. This research is part of the development of the sensing interface for amputees, specifically addressing the analysis of human perception while grasping. The goal is to determine the small number of preferred positions of sensors on the prosthetic hand. This task has previously been approached by trying to replicate a natural sensory system characteristic for healthy humans, resulting in a multitude of redundant sensors and basic inability to make the patient aware of the sensor readings on the subconscious level. We based our artificial perception system on the reported sensations of humans when grasping various objects without seeing the objects (obstructed visual feedback. Subjects, with no known sensory deficits, were asked to report on the touch sensation while grasping. The analysis included objects of various sizes, weights, textures and temperatures. Based on this data we formed a map of the preferred positions for the sensors that is appropriate for five finger human-like robotic hand. The final map was intentionally minimized in size (number of sensors.

  20. Natural-pose hand detection in low-resolution images

    Directory of Open Access Journals (Sweden)

    Nyan Bo Bo1

    2009-07-01

    Full Text Available Robust real-time hand detection and tracking in video sequences would enable many applications in areas as diverse ashuman-computer interaction, robotics, security and surveillance, and sign language-based systems. In this paper, we introducea new approach for detecting human hands that works on single, cluttered, low-resolution images. Our prototype system, whichis primarily intended for security applications in which the images are noisy and low-resolution, is able to detect hands as smallas 2424 pixels in cluttered scenes. The system uses grayscale appearance information to classify image sub-windows as eithercontaining or not containing a human hand very rapidly at the cost of a high false positive rate. To improve on the false positiverate of the main classifier without affecting its detection rate, we introduce a post-processor system that utilizes the geometricproperties of skin color blobs. When we test our detector on a test image set containing 106 hands, 92 of those hands aredetected (86.8% detection rate, with an average false positive rate of 1.19 false positive detections per image. The rapiddetection speed, the high detection rate of 86.8%, and the low false positive rate together ensure that our system is useable asthe main detector in a diverse variety of applications requiring robust hand detection and tracking in low-resolution, clutteredscenes.

  1. Detectable states, cycle fluxes, and motility scaling of molecular motor kinesin: An integrative kinetic graph theory analysis

    Science.gov (United States)

    Ren, Jie

    2017-12-01

    The process by which a kinesin motor couples its ATPase activity with concerted mechanical hand-over-hand steps is a foremost topic of molecular motor physics. Two major routes toward elucidating kinesin mechanisms are the motility performance characterization of velocity and run length, and single-molecular state detection experiments. However, these two sets of experimental approaches are largely uncoupled to date. Here, we introduce an integrative motility state analysis based on a theorized kinetic graph theory for kinesin, which, on one hand, is validated by a wealth of accumulated motility data, and, on the other hand, allows for rigorous quantification of state occurrences and chemomechanical cycling probabilities. An interesting linear scaling for kinesin motility performance across species is discussed as well. An integrative kinetic graph theory analysis provides a powerful tool to bridge motility and state characterization experiments, so as to forge a unified effort for the elucidation of the working mechanisms of molecular motors.

  2. Combining heterogenous features for 3D hand-held object recognition

    Science.gov (United States)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  3. Kinetics of Reactive Fronts in Porous Media: quantification through a laboratory experiment

    Science.gov (United States)

    De Anna, P.; Jimenez-Martinez, J.; Turuban, R.; Tabuteau, H.; Derrien, M.; Le Borgne, T.; Meheust, Y.

    2013-12-01

    The kinetics of reaction fronts in heterogeneous flows is tightly linked to the mixing dynamics governed by the combined action of stretching, diffusion and dispersion. Focusing on porous media flows, with a new experimental setup we show that the invading solute is organized into stretched lamellae, whose deformation and coalescence control the effective reaction kinetics of the mixing limited bimolecular reaction A + B --> C. While the classic advection-dispersion theory predicts a scaling of the cumulative product mass of C as t^(0.5), we observe two distinct kinetics regimes, one characterized by the stretching and the other by the coalescence of the invading lamellae, in which the mass of C scales faster than t^(0.5). The proposed experimental set up allows for direct quantification of mixing and reactive transport in porous media with a high spatial resolution, at the pore scale. The analogous two dimensional porous medium consists in a Hele-Shaw cell containing a single layer of cylindrical solid grains built by soft lithography. On the one hand, the measurement of the local, intra-pore, conservative concentration field is done using a fluorescent tracer. On the other hand, considering a fast bimolecular advection-dispersion reaction A + B --> C occurring as A displaces B, we quantify the reaction kinetics from the spatially-resolved measurement of the pore scale reaction rate, using a chemiluminescent reaction.

  4. Expression and kinetic properties of a recombinant 3 alpha-hydroxysteroid/dihydrodiol dehydrogenase isoenzyme of human liver.

    Science.gov (United States)

    Deyashiki, Y; Tamada, Y; Miyabe, Y; Nakanishi, M; Matsuura, K; Hara, A

    1995-08-01

    Human liver cytosol contains multiple forms of 3 alpha-hydroxysteroid dehydrogenase and dihydrodiol dehydrogenase with hydroxysteroid dehydrogenase activity, and multiple cDNAs for the enzymes have been cloned from human liver cDNA libraries. To understand the relationship of the multiple enzyme froms to the genes, a cDNA, which has been reported to code for an isoenzyme of human liver 3 alpha-hydroxysteroid/dihydrodiol dehydrogenase, was expressed in Escherichia coli. The recombinant enzyme showed structural and functional properties almost identical to those of the isoenzyme purified from human liver. In addition, the recombinant isoenzyme efficiently reduced 5 alpha-dihydrotestosterone and 5 beta-dihydrocortisone, the known substrates of human liver 3 alpha-hydroxysteroid dehydrogenase and chlordecone reductase previously purified, which suggests that these human liver enzymes are identical. Furthermore, the steady-state kinetic data for NADP(+)-linked (S)-1-indanol oxidation by the recombinant isoenzyme were consistent with a sequential ordered mechanism in which NADP+ binds first. Phenolphthalein inhibited this isoenzyme much more potently than it did the other human liver dihydrodiol dehydrogenases, and was a competitive inhibitor (Ki = 20 nM) that bound to the enzyme-NADP+ complex.

  5. Human motion retrieval from hand-drawn sketch.

    Science.gov (United States)

    Chao, Min-Wen; Lin, Chao-Hung; Assa, Jackie; Lee, Tong-Yee

    2012-05-01

    The rapid growth of motion capture data increases the importance of motion retrieval. The majority of the existing motion retrieval approaches are based on a labor-intensive step in which the user browses and selects a desired query motion clip from the large motion clip database. In this work, a novel sketching interface for defining the query is presented. This simple approach allows users to define the required motion by sketching several motion strokes over a drawn character, which requires less effort and extends the users’ expressiveness. To support the real-time interface, a specialized encoding of the motions and the hand-drawn query is required. Here, we introduce a novel hierarchical encoding scheme based on a set of orthonormal spherical harmonic (SH) basis functions, which provides a compact representation, and avoids the CPU/processing intensive stage of temporal alignment used by previous solutions. Experimental results show that the proposed approach can well retrieve the motions, and is capable of retrieve logically and numerically similar motions, which is superior to previous approaches. The user study shows that the proposed system can be a useful tool to input motion query if the users are familiar with it. Finally, an application of generating a 3D animation from a hand-drawn comics strip is demonstrated.

  6. Where one hand meets the other: limb-specific and action-dependent movement plans decoded from preparatory signals in single human frontoparietal brain areas.

    Science.gov (United States)

    Gallivan, Jason P; McLean, D Adam; Flanagan, J Randall; Culham, Jody C

    2013-01-30

    Planning object-directed hand actions requires successful integration of the movement goal with the acting limb. Exactly where and how this sensorimotor integration occurs in the brain has been studied extensively with neurophysiological recordings in nonhuman primates, yet to date, because of limitations of non-invasive methodologies, the ability to examine the same types of planning-related signals in humans has been challenging. Here we show, using a multivoxel pattern analysis of functional MRI (fMRI) data, that the preparatory activity patterns in several frontoparietal brain regions can be used to predict both the limb used and hand action performed in an upcoming movement. Participants performed an event-related delayed movement task whereby they planned and executed grasp or reach actions with either their left or right hand toward a single target object. We found that, although the majority of frontoparietal areas represented hand actions (grasping vs reaching) for the contralateral limb, several areas additionally coded hand actions for the ipsilateral limb. Notable among these were subregions within the posterior parietal cortex (PPC), dorsal premotor cortex (PMd), ventral premotor cortex, dorsolateral prefrontal cortex, presupplementary motor area, and motor cortex, a region more traditionally implicated in contralateral movement generation. Additional analyses suggest that hand actions are represented independently of the intended limb in PPC and PMd. In addition to providing a unique mapping of limb-specific and action-dependent intention-related signals across the human cortical motor system, these findings uncover a much stronger representation of the ipsilateral limb than expected from previous fMRI findings.

  7. Ultra-weak photon emission as a non-invasive tool for monitoring of oxidative processes in the epidermal cells of human skin: comparative study on the dorsal and the palm side of the hand.

    Science.gov (United States)

    Rastogi, Anshu; Pospísil, Pavel

    2010-08-01

    All living organisms emit spontaneous ultra-weak photon emission as a result of cellular metabolic processes. Exposure of living organisms to exogenous factors results in oxidative processes and enhancement in ultra-weak photon emission. Here, hydrogen peroxide (H(2)O(2)), as a strongly oxidizing molecule, was used to induce oxidative processes and enhance ultra-weak photon emission in human hand skin. The presented work intends to compare both spontaneous and peroxide-induced ultra-weak photon emission from the epidermal cells on the dorsal and the palm side of the hand. A highly sensitive photomultiplier tube and a charge-coupled device camera were used to detect ultra-weak photon emission from human hand skin. Spontaneous ultra-weak photon emission from the epidermal cells on the dorsal side of the hand was 4 counts/s. Topical application of 500 mM H(2)O(2) to the dorsal side of the hand caused enhancement in ultra-weak photon emission to 40 counts/s. Interestingly, both spontaneous and peroxide-induced ultra-weak photon emission from the epidermal cells on the palm side of the hand were observed to increase twice their values, i.e. 8 and 80 counts/s, respectively. Similarly, the two-dimensional image of ultra-weak photon emission observed after topical application of H(2)O(2) to human skin reveals that photon emission from the palm side exceeds the photon emission from the dorsal side of the hand. The results presented indicate that the ultra-weak photon emission originating from the epidermal cells on the dorsal and the palm side of the hand is related to the histological structure of the human hand skin. Ultra-weak photon emission is shown as a non-destructive technique for monitoring of oxidative processes in the epidermal cells of the human hand skin and as a diagnostic tool for skin diseases.

  8. Surface EMG in advanced hand prosthetics.

    Science.gov (United States)

    Castellini, Claudio; van der Smagt, Patrick

    2009-01-01

    One of the major problems when dealing with highly dexterous, active hand prostheses is their control by the patient wearing them. With the advances in mechatronics, building prosthetic hands with multiple active degrees of freedom is realisable, but actively controlling the position and especially the exerted force of each finger cannot yet be done naturally. This paper deals with advanced robotic hand control via surface electromyography. Building upon recent results, we show that machine learning, together with a simple downsampling algorithm, can be effectively used to control on-line, in real time, finger position as well as finger force of a highly dexterous robotic hand. The system determines the type of grasp a human subject is willing to use, and the required amount of force involved, with a high degree of accuracy. This represents a remarkable improvement with respect to the state-of-the-art of feed-forward control of dexterous mechanical hands, and opens up a scenario in which amputees will be able to control hand prostheses in a much finer way than it has so far been possible.

  9. Release of Virus from Lymphoid Tissue Affects Human Immunodeficiency Virus Type 1 and Hepatitis C Virus Kinetics in the Blood

    NARCIS (Netherlands)

    Müller, Viktor; Marée, Athanasius F.M.; Boer, R.J. de

    2000-01-01

    Kinetic parameters of human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) infections have been estimated from plasma virus levels following perturbation of the chronically infected (quasi-) steady state. We extend previous models by also considering the large pool of virus

  10. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    International Nuclear Information System (INIS)

    Ismail, S S; Mohamad, M; Syazarina, S O; Nafisah, W Y

    2014-01-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain

  11. Hand grips strength effect on motor function in human brain using fMRI: a pilot study

    Science.gov (United States)

    Ismail, S. S.; Mohamad, M.; Syazarina, S. O.; Nafisah, W. Y.

    2014-11-01

    Several methods of motor tasks for fMRI scanning have been evolving from simple to more complex tasks. Motor tasks on upper extremity were applied in order to excite the increscent of motor activation on contralesional and ipsilateral hemispheres in brain. The main objective of this study is to study the different conditions for motor tasks on upper extremity that affected the brain activation. Ten healthy right handed with normal vision (3 male and 7 female, age range=20-30 years, mean=24.6 years, SD=2.21) participated in this study. Prior to the scanning, participants were trained on hand grip tasks using rubber ball and pressure gauge tool outside the scanner. During fMRI session, a block design with 30-s task blocks and alternating 30-s rest periods was employed while participants viewed a computer screen via a back projection-mirror system and instructed to follow the instruction by gripping their hand with normal and strong grips using a rubber ball. Statistical Parametric mapping (SPM8) software was used to determine the brain activation. Both tasks activated the primary motor (M1), supplementary motor area (SMA), dorsal and ventral of premotor cortex area (PMA) in left hemisphere while in right hemisphere the area of primary motor (M1) somatosensory was activated. However, the comparison between both tasks revealed that the strong hand grip showed the higher activation at M1, PMA and SMA on left hemisphere and also the area of SMA on right hemisphere. Both conditions of motor tasks could provide insights the functional organization on human brain.

  12. Kinetic and allometric models for dosimetry using radiopharmaceuticals labeled with lanthanides

    International Nuclear Information System (INIS)

    Lima, Marina Ferreira

    2012-01-01

    This work proposes two models based in compartmental analyses: Animal model and Human model, using images from gamma camera measurements to determinate the kinetic constants of the 177 Lu-DOTATATE to three animal species (rat Wistar, Armenian hamster and Syrian hamster) and to the human in biodistribution studies split in two phases: Phase 1 governed by uptake from the blood and Phase 2 governed by the real excretion. The kinetic constants obtained from the animals' data ere used to build allometric scaling to predict radiopharmaceutical biodistribution in the human employing relations by mass, metabolism, by life span and by physiological parameters. These extrapolation results were compared with the PRRT (Peptide receptor radiotherapy) patients kinetic data calculated using the Human model. The kinetic constants obtained from humans were used in dose assessment to PRRT patients considering MIRD 26 organs and tissues. Dosimetry results were in agreement with available results from literature. For the Phase 1 allometric scaling from kinetic data from the blood to the organs straight responsible for the 177 Lu-DOTATATE metabolism and excretion - liver, kidneys and urinary bladder -show good correlation in the scaling by mass, metabolism and physiological and parameters. For the Phase 2, only the kinetic data from blood to the liver and to the kidneys show good correlation. Based in the anaesthetics inhibitory action over the renal excretion, there is not empirical basis to allow measurement times over 40 minutes in in vivo studies with small animals. Consequently, the Phase 1 results seem enough to make allometric scaling to assessment dose in PRRT. (author)

  13. Cytomegalovirus Survival and Transferability and the Effectiveness of Common Hand-Washing Agents against Cytomegalovirus on Live Human Hands

    OpenAIRE

    Stowell, Jennifer D.; Forlin-Passoni, Daniela; Radford, Kay; Bate, Sheri L.; Dollard, Sheila C.; Bialek, Stephanie R.; Cannon, Michael J.; Schmid, D. Scott

    2014-01-01

    Congenital cytomegalovirus (CMV) transmission can occur when women acquire CMV while pregnant. Infection control guidelines may reduce risk for transmission. We studied the duration of CMV survival after application of bacteria to the hands and after transfer from the hands to surfaces and the effectiveness of cleansing with water, regular and antibacterial soaps, sanitizer, and diaper wipes. Experiments used CMV AD169 in saliva at initial titers of 1 × 105 infectious particles/ml. Samples fr...

  14. Age-related changes in cutaneous sensation in the healthy human hand.

    Science.gov (United States)

    Bowden, Jocelyn L; McNulty, Penelope A

    2013-08-01

    Cutaneous sensation deteriorates with age. It is not known if this change is consistent over the entire hand or if sensation is affected by changes in skin mechanics. Cutaneous perceptual thresholds were tested at eight sites in the glabrous skin and two in the hairy skin of both hands in 70 subjects (20-88 years), five male and five female per decade, using calibrated von Frey filaments, two-point discrimination, and texture discrimination. Venous occlusion at the wrist (40 ± 10 mmHg) and moisturizer were used to alter skin mechanics. Cutaneous thresholds increased significantly with age (p sensation varied according to the site tested with smaller changes on the fingers compared to the palm. Two-point discrimination deteriorated with age (p = 0.046), but with no interaction between sex, handedness, or changes in skin mechanics. There were no significant differences for texture discrimination. Changes in skin mechanics improved cutaneous thresholds in the oldest males after moisturizing (p = 0.001) but not otherwise. These results emphasize the complex pattern of age-related deterioration in cutaneous sensation with differences between sexes, the hands, sites on the hand, and the mode of testing. As the index fingertip is not a sensitive indicator of sensory decline, the minimum assessment of age-related changes in cutaneous sensation should include both hands, and sites on the palm.

  15. [Study on an Exoskeleton Hand Function Training Device].

    Science.gov (United States)

    Hu, Xin; Zhang, Ying; Li, Jicai; Yi, Jinhua; Yu, Hongliu; He, Rongrong

    2016-02-01

    Based on the structure and motion bionic principle of the normal adult fingers, biological characteristics of human hands were analyzed, and a wearable exoskeleton hand function training device for the rehabilitation of stroke patients or patients with hand trauma was designed. This device includes the exoskeleton mechanical structure and the electromyography (EMG) control system. With adjustable mechanism, the device was capable to fit different finger lengths, and by capturing the EMG of the users' contralateral limb, the motion state of the exoskeleton hand was controlled. Then driven by the device, the user's fingers conducting adduction/abduction rehabilitation training was carried out. Finally, the mechanical properties and training effect of the exoskeleton hand were verified through mechanism simulation and the experiments on the experimental prototype of the wearable exoskeleton hand function training device.

  16. Complex tasks force hand laterality and technological behaviour in naturalistically housed chimpanzees: inferences in hominin evolution.

    Science.gov (United States)

    Mosquera, M; Geribàs, N; Bargalló, A; Llorente, M; Riba, D

    2012-01-01

    Clear hand laterality patterns in humans are widely accepted. However, humans only elicit a significant hand laterality pattern when performing complementary role differentiation (CRD) tasks. Meanwhile, hand laterality in chimpanzees is weaker and controversial. Here we have reevaluated our results on hand laterality in chimpanzees housed in naturalistic environments at Fundació Mona (Spain) and Chimfunshi Wild Orphanage (Zambia). Our results show that the difference between hand laterality in humans and chimpanzees is not as great as once thought. Furthermore, we found a link between hand laterality and task complexity and also an even more interesting connection: CRD tasks elicited not only the hand laterality but also the use of tools. This paper aims to turn attention to the importance of this threefold connection in human evolution: the link between CRD tasks, hand laterality, and tool use, which has important evolutionary implications that may explain the development of complex behaviour in early hominins.

  17. Decoding Individual Finger Movements from One Hand Using Human EEG Signals

    Science.gov (United States)

    Gonzalez, Jania; Ding, Lei

    2014-01-01

    Brain computer interface (BCI) is an assistive technology, which decodes neurophysiological signals generated by the human brain and translates them into control signals to control external devices, e.g., wheelchairs. One problem challenging noninvasive BCI technologies is the limited control dimensions from decoding movements of, mainly, large body parts, e.g., upper and lower limbs. It has been reported that complicated dexterous functions, i.e., finger movements, can be decoded in electrocorticography (ECoG) signals, while it remains unclear whether noninvasive electroencephalography (EEG) signals also have sufficient information to decode the same type of movements. Phenomena of broadband power increase and low-frequency-band power decrease were observed in EEG in the present study, when EEG power spectra were decomposed by a principal component analysis (PCA). These movement-related spectral structures and their changes caused by finger movements in EEG are consistent with observations in previous ECoG study, as well as the results from ECoG data in the present study. The average decoding accuracy of 77.11% over all subjects was obtained in classifying each pair of fingers from one hand using movement-related spectral changes as features to be decoded using a support vector machine (SVM) classifier. The average decoding accuracy in three epilepsy patients using ECoG data was 91.28% with the similarly obtained features and same classifier. Both decoding accuracies of EEG and ECoG are significantly higher than the empirical guessing level (51.26%) in all subjects (pEEG as in ECoG, and demonstrates the feasibility of discriminating finger movements from one hand using EEG. These findings are promising to facilitate the development of BCIs with rich control signals using noninvasive technologies. PMID:24416360

  18. Order-disorder transitions govern kinetic cooperativity and allostery of monomeric human glucokinase.

    Directory of Open Access Journals (Sweden)

    Mioara Larion

    Full Text Available Glucokinase (GCK catalyzes the rate-limiting step of glucose catabolism in the pancreas, where it functions as the body's principal glucose sensor. GCK dysfunction leads to several potentially fatal diseases including maturity-onset diabetes of the young type II (MODY-II and persistent hypoglycemic hyperinsulinemia of infancy (PHHI. GCK maintains glucose homeostasis by displaying a sigmoidal kinetic response to increasing blood glucose levels. This positive cooperativity is unique because the enzyme functions exclusively as a monomer and possesses only a single glucose binding site. Despite nearly a half century of research, the mechanistic basis for GCK's homotropic allostery remains unresolved. Here we explain GCK cooperativity in terms of large-scale, glucose-mediated disorder-order transitions using 17 isotopically labeled isoleucine methyl groups and three tryptophan side chains as sensitive nuclear magnetic resonance (NMR probes. We find that the small domain of unliganded GCK is intrinsically disordered and samples a broad conformational ensemble. We also demonstrate that small-molecule diabetes therapeutic agents and hyperinsulinemia-associated GCK mutations share a strikingly similar activation mechanism, characterized by a population shift toward a more narrow, well-ordered ensemble resembling the glucose-bound conformation. Our results support a model in which GCK generates its cooperative kinetic response at low glucose concentrations by using a millisecond disorder-order cycle of the small domain as a "time-delay loop," which is bypassed at high glucose concentrations, providing a unique mechanism to allosterically regulate the activity of human GCK under physiological conditions.

  19. Kinetic model for hydroxyapatite precipitation on human enamel surface by electrolytic deposition

    Energy Technology Data Exchange (ETDEWEB)

    Lei Caixia; Liao Yingmin; Feng Zude, E-mail: zdfeng@xmu.edu.c [College of Materials, Xiamen University, Xiamen 361005 (China)

    2009-06-15

    The electrolytic deposition (ELD) of hydroxyapatite (HAP) coating on human enamel surface for different loading times at varied temperatures (ranging from 37 deg. C to 85 deg. C) and varied current densities (ranging from 0.05 mA cm{sup -2} to 10 mA cm{sup -2}) was investigated in this study. Thin film x-ray diffraction, Fourier transform infrared and micro-Raman spectra analysis, as well as an environmental scanning electron microscope, were used to characterize the coating. The results showed that only the HAP phase occurred on the enamel surface after ELD experiments. The contents of HAP deposits on the enamel surface linearly changed proportional to the square root of the loading time, which was in good agreement with the kinetic model of ELD of HAP coating based on one-dimensional diffusion. The induction periods were observed on all the regression lines, and the rate of the HAP coating formation on enamel showed a linear relationship with the current density. It was implied that the diffusion process was the rate-determining step in the ELD of the HAP coating on human enamel.

  20. Novel Approach to Control of Robotic Hand Using Flex Sensors

    Directory of Open Access Journals (Sweden)

    Sandesh R.S

    2014-05-01

    Full Text Available This paper discuss about novel design approach to control of a robotic hand using flex sensors which indicates a biomechatronic multi fingered robotic hand. This robotic hand consists of base unit, upper arm, lower arm, palm and five fingers. The aim is to develop an anthropomorphic five fingered robotic hand. The proposed design illustrates the use of 5 micro DC motors with 9 Degrees of Freedom (DOF.Each finger is controlled independently. Further three extra motors were used for the control of wrist elbow and base movement. The study of the DC motor is being carried out using the transfer function model for constant excitation. The micro DC motor performance was analyzed using MATLAB simulation environment. The whole system is implemented using flex sensors. The flex sensors placed on the human hand gloves appear as if they look like real human hand.  89v51 microcontroller was used for all the controlling actions along with RF transmitter/receiver .The performance of the system has been conducted experimentally and studied.

  1. The Kinetic Chain Revisited: New Concepts on Throwing Mechanics and Injury.

    Science.gov (United States)

    Chu, Samuel K; Jayabalan, Prakash; Kibler, W Ben; Press, Joel

    2016-03-01

    The overhead throwing motion is a complex activity that is achieved through activation of the kinetic chain. The kinetic chain refers to the linkage of multiple segments of the body that allows for transfer of forces and motion. The lower extremities and core provide a base of support, generating energy that is transferred eventually through the throwing arm and hand, resulting in release of the ball. The kinetic chain requires optimal anatomy, physiology, and mechanics and is involved in all 6 phases of overhead throwing: windup, stride, arm cocking, acceleration, deceleration, and follow-through. Breaks or deficits in the kinetic chain can lead to injury or decreased performance. Through an understanding of the mechanics and pathomechanics seen in each phase of throwing, the clinician can better evaluate and screen for potential kinetic chain deficits in the overhead throwing athlete. The purpose of this article is to review the biomechanics of the overhead throwing motion, the role of the kinetic chain in throwing, and the clinical evaluation and management of abnormal throwing mechanics and related injuries. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  2. The Making of a 3D-Printed, Cable-Driven, Single-Model, Lightweight Humanoid Robotic Hand

    Directory of Open Access Journals (Sweden)

    Li Tian

    2017-12-01

    Full Text Available Dexterity robotic hands can (Cummings, 1996 greatly enhance the functionality of humanoid robots, but the making of such hands with not only human-like appearance but also the capability of performing the natural movement of social robots is a challenging problem. The first challenge is to create the hand’s articulated structure and the second challenge is to actuate it to move like a human hand. A robotic hand for humanoid robot should look and behave human like. At the same time, it also needs to be light and cheap for widely used purposes. We start with studying the biomechanical features of a human hand and propose a simplified mechanical model of robotic hands, which can achieve the important local motions of the hand. Then, we use 3D modeling techniques to create a single interlocked hand model that integrates pin and ball joints to our hand model. Compared to other robotic hands, our design saves the time required for assembling and adjusting, which makes our robotic hand ready-to-use right after the 3D printing is completed. Finally, the actuation of the hand is realized by cables and motors. Based on this approach, we have designed a cost-effective, 3D printable, compact, and lightweight robotic hand. Our robotic hand weighs 150 g, has 15 joints, which are similar to a real human hand, and 6 Degree of Freedom (DOFs. It is actuated by only six small size actuators. The wrist connecting part is also integrated into the hand model and could be customized for different robots such as Nadine robot (Magnenat Thalmann et al., 2017. The compact servo bed can be hidden inside the Nadine robot’s sleeve and the whole robotic hand platform will not cause extra load to her arm as the total weight (150 g robotic hand and 162 g artificial skin is almost the same as her previous unarticulated robotic hand which is 348 g. The paper also shows our test results with and without silicon artificial hand skin, and on Nadine robot.

  3. Design of a 3-DOF Parallel Hand-Controller

    Directory of Open Access Journals (Sweden)

    Chengcheng Zhu

    2017-01-01

    Full Text Available Hand-controllers, as human-machine-interface (HMI devices, can transfer the position information of the operator’s hands into the virtual environment to control the target objects or a real robot directly. At the same time, the haptic information from the virtual environment or the sensors on the real robot can be displayed to the operator. It helps human perceive haptic information more truly with feedback force. A parallel hand-controller is designed in this paper. It is simplified from the traditional delta haptic device. The swing arms in conventional delta devices are replaced with the slider rail modules. The base consists of two hexagons and several links. For the use of the linear sliding modules instead of swing arms, the arc movement is replaced by linear movement. So that, the calculating amount of the position positive solution and the force inverse solution is reduced for the simplification of the motion. The kinematics, static mechanics, and dynamic mechanics are analyzed in this paper. What is more, two demonstration applications are developed to verify the performance of the designed hand-controller.

  4. Diagnostic Appraisal of Grade 12 Students' Understanding of Reaction Kinetics

    Science.gov (United States)

    Yan, Yaw Kai; Subramaniam, R.

    2016-01-01

    The study explored grade 12 students' understanding of reaction kinetics, a topic which has not been extensively explored in the chemistry education literature at this level. A 3-tier diagnostic instrument with 11 questions was developed--this format is of very recent origin and has been the subject of only a handful of studies. The findings…

  5. No Effect of TETRA Hand Portable Transmission Signals on Human Cognitive Function and Symptoms

    DEFF Research Database (Denmark)

    Riddervold, Ingunn Skogstad; Kjærgaard, Søren K.; Pedersen, Gert F.

    2010-01-01

    Current radio frequency radiation exposure guidelines rest on well-established thermal effects. However, recent research into analogue and digital transmission fields at levels covered by the exposure guidelines has indicated possible detrimental effects on human cognitive performance. To investi......Current radio frequency radiation exposure guidelines rest on well-established thermal effects. However, recent research into analogue and digital transmission fields at levels covered by the exposure guidelines has indicated possible detrimental effects on human cognitive performance....... To investigate this, we conducted a controlled climate chamber study of possible changes in cognitive performance in healthy volunteers exposed to transmission signals from TETRA hand portables (TETRA handsets). The trial deployed a balanced, randomized, double-blinded cross-over design. Performance on different...... paper-and-pencil, auditory and computer-based cognitive tasks was monitored in 53 male volunteers (mean age 36.41 years, SD 8.35) during 45-min exposure to a TETRA handset and sham control signals remotely controlled from a laboratory more than 100 km away. The main cognitive outcome was the Trail...

  6. [Bertha Röntgen or the transparency of the hand].

    Science.gov (United States)

    Picard, J D

    1996-01-01

    It is to Wilhelm Conrad Röntgen, the first elected "radiologist" of our Academy and the first Nobel Prize winner in physics, that we owe the transparency of the hand. We celebrate today the centenary of the great scientific discovery which was to revolutionize the diagnosis, and thereby the treatment, of a large number of illnesses the discovery of X-rays. It would be unjust not to link the name of this scientist with that of his wife, Bertha, who, ignorant of the dangers of all "novel medical inventions" volunteered her own hand for his research experiments: the hand which was to bring to the world tangible proof of this remarkable discovery. To a lesser degree, but nonetheless essential, we acknowledge, albeit not in exhaustive detail, all the progress made by the work of pioneers using this new investigative technique. So let us now return to the hand:--a body part which it was easy to immobilize, remembering that in those days a single radiographic exposure took up to an hour to obtain,--we will consider the immortalised hand of Bertha Röntgen,---to whom this address is dedicated,---and its radiographic exposures which allow us to appreciate the advances and to perceive the limitations of this technique. They also enable us better to envisage future investigative approaches whereby a deeper knowledge of the human body may be acquired. We note that compared with the histopathological sciences, imaging is not specific. Numerous microscopic structures, in particular neurological and vascular ones, are still insufficiently well visualised and the transmission pathways between the hand and the central nervous system deserve better characterisation. Current, research programmes are attempting to overcome these limitation of modern imaging. All the experience gained in studying the transparency of the hand, as we have discussed, is applicable to every part of the human anatomy. To credit: Röntgen's discovery with all its originality, we could say that the hand was

  7. Beyond mean-field approximations for accurate and computationally efficient models of on-lattice chemical kinetics

    Science.gov (United States)

    Pineda, M.; Stamatakis, M.

    2017-07-01

    Modeling the kinetics of surface catalyzed reactions is essential for the design of reactors and chemical processes. The majority of microkinetic models employ mean-field approximations, which lead to an approximate description of catalytic kinetics by assuming spatially uncorrelated adsorbates. On the other hand, kinetic Monte Carlo (KMC) methods provide a discrete-space continuous-time stochastic formulation that enables an accurate treatment of spatial correlations in the adlayer, but at a significant computation cost. In this work, we use the so-called cluster mean-field approach to develop higher order approximations that systematically increase the accuracy of kinetic models by treating spatial correlations at a progressively higher level of detail. We further demonstrate our approach on a reduced model for NO oxidation incorporating first nearest-neighbor lateral interactions and construct a sequence of approximations of increasingly higher accuracy, which we compare with KMC and mean-field. The latter is found to perform rather poorly, overestimating the turnover frequency by several orders of magnitude for this system. On the other hand, our approximations, while more computationally intense than the traditional mean-field treatment, still achieve tremendous computational savings compared to KMC simulations, thereby opening the way for employing them in multiscale modeling frameworks.

  8. Real-Time Hand Posture Recognition Using a Range Camera

    Science.gov (United States)

    Lahamy, Herve

    The basic goal of human computer interaction is to improve the interaction between users and computers by making computers more usable and receptive to the user's needs. Within this context, the use of hand postures in replacement of traditional devices such as keyboards, mice and joysticks is being explored by many researchers. The goal is to interpret human postures via mathematical algorithms. Hand posture recognition has gained popularity in recent years, and could become the future tool for humans to interact with computers or virtual environments. An exhaustive description of the frequently used methods available in literature for hand posture recognition is provided. It focuses on the different types of sensors and data used, the segmentation and tracking methods, the features used to represent the hand postures as well as the classifiers considered in the recognition process. Those methods are usually presented as highly robust with a recognition rate close to 100%. However, a couple of critical points necessary for a successful real-time hand posture recognition system require major improvement. Those points include the features used to represent the hand segment, the number of postures simultaneously recognizable, the invariance of the features with respect to rotation, translation and scale and also the behavior of the classifiers against non-perfect hand segments for example segments including part of the arm or missing part of the palm. A 3D time-of-flight camera named SR4000 has been chosen to develop a new methodology because of its capability to provide in real-time and at high frame rate 3D information on the scene imaged. This sensor has been described and evaluated for its capability for capturing in real-time a moving hand. A new recognition method that uses the 3D information provided by the range camera to recognize hand postures has been proposed. The different steps of this methodology including the segmentation, the tracking, the hand

  9. Kinetics of human serum amyloid A

    International Nuclear Information System (INIS)

    Rosenthal, C.J.; Martin, M.E.; Solomon, N.

    1986-01-01

    In order to better understand the pathogenetic role of serum amyloid A (SAA) we studied the kinetics of 131 I radiolabelled pure SAA, extracted from 400 ml serum of a human volunteer. 50 microCi of 131 I SAA and 15 microCi 125 I labelled sodium iodide were administered i.v. on two occasions at 6 month intervals. Serum and plasma samples were collected at 10-20 min intervals x 10, then once daily x 10; lymphocytes were separated from monocytes and granulocytes. Counts per minute of 131 I and 125 I were measured in each sample in the serum, in serum precipitates resulting after addition of a rabbit anti-SAA antibody and of TCA and in various cell subpopulations as well as in the whole urine and TCA precipitated urine from each micturition. The 131 I disappearance curves from the plasma and serum precipitates were semilogarithmically plotted; cumulative 131 I cpm in plasma, cells and urine at various intervals were determined. Body scanning was performed at 2, 16, and 48 h. The results of the two experiments were very similar. The curve of 131 I SAA in plasma TCA precipitates indicated the existence of 4 compartments likely due to uptake of 131 I SAA by some plasma proteins, circulating cells and other tissues; later release from tissues started at 6 h. The 131 I SAA half-life time in these compartments was found to be 35, 170, 255, and 550 min, respectively. Tissue binding of 131 I was also suggested by a rising of the 125 I: 131 I ratio with time and by a 26% release of 131 I in the urine at 15 h which could not account for its plasma disappearance. Scanning, except for 131 I uptake in the spleen at 2 h likely due to blood activity, showed no organ concentration. 92% of the injected 131 I was found in the urine but only 6.2% of 131 I SAA was accounted for in urine precicipitates

  10. fMRI-compatible rehabilitation hand device

    Directory of Open Access Journals (Sweden)

    Tzika Aria

    2006-10-01

    Full Text Available Abstract Background Functional magnetic resonance imaging (fMRI has been widely used in studying human brain functions and neurorehabilitation. In order to develop complex and well-controlled fMRI paradigms, interfaces that can precisely control and measure output force and kinematics of the movements in human subjects are needed. Optimized state-of-the-art fMRI methods, combined with magnetic resonance (MR compatible robotic devices for rehabilitation, can assist therapists to quantify, monitor, and improve physical rehabilitation. To achieve this goal, robotic or mechatronic devices with actuators and sensors need to be introduced into an MR environment. The common standard mechanical parts can not be used in MR environment and MR compatibility has been a tough hurdle for device developers. Methods This paper presents the design, fabrication and preliminary testing of a novel, one degree of freedom, MR compatible, computer controlled, variable resistance hand device that may be used in brain MR imaging during hand grip rehabilitation. We named the device MR_CHIROD (Magnetic Resonance Compatible Smart Hand Interfaced Rehabilitation Device. A novel feature of the device is the use of Electro-Rheological Fluids (ERFs to achieve tunable and controllable resistive force generation. ERFs are fluids that experience dramatic changes in rheological properties, such as viscosity or yield stress, in the presence of an electric field. The device consists of four major subsystems: a an ERF based resistive element; b a gearbox; c two handles and d two sensors, one optical encoder and one force sensor, to measure the patient induced motion and force. The smart hand device is designed to resist up to 50% of the maximum level of gripping force of a human hand and be controlled in real time. Results Laboratory tests of the device indicate that it was able to meet its design objective to resist up to approximately 50% of the maximum handgrip force. The detailed

  11. In vitro studies of ante-mortem proliferation kinetics

    International Nuclear Information System (INIS)

    McBride, W.H.; Withers, H.R.

    1986-01-01

    Using K562 human erythroblastoid cells, it was concluded that dose fractionation has no discrepant effect on the ante-mortem proliferation kinetics of doomed cells as opposed to clonogenic cell survival and that effects on ante-mortem proliferation kinetics cannot be solely responsible for the differences in fractionation response between early and late responding tissues. (UK)

  12. Presteady-state and steady-state kinetic properties of human cytochrome c oxidase. Identification of rate-limiting steps in mammalian cytochrome c oxidase

    NARCIS (Netherlands)

    van Kuilenburg, A. B.; Gorren, A. C.; Dekker, H. L.; Nieboer, P.; van Gelder, B. F.; Muijsers, A. O.

    1992-01-01

    Human cytochrome c oxidase was purified in a fully active form from heart and skeletal muscle. The enzyme was selectively solubilised with octylglucoside and KCl from submitochondrial particles followed by ammonium sulphate fractionation. The presteady-state and steady-state kinetic properties of

  13. Controller design for Robotic hand through Electroencephalogram

    OpenAIRE

    Pandelidis P.; Kiriazis N.; Orgianelis K.; Koulios N.

    2016-01-01

    - This paper deals with the designing, the construction and the control of a robotic hand via an electroencephalogram sensor. First a robotic device that is able to mimic a real human hand is constructed. A PID controller is designed in order to improve the performance of the robotic arm for grabbing objects. Furthermore, a novel design approach is presented for controlling the motion of the robotic arm using signals produced from an innovative electroencephalogram sensor that detects the con...

  14. A new kinetic model for human iodine metabolism

    International Nuclear Information System (INIS)

    Ficken, V.J.; Allen, E.W.; Adams, G.D.

    1985-01-01

    A new kinetic model of iodine metabolism incorporating preferential organification of tyrosil (TYR) residues of thyroglobulin is developed and evaluated for euthyroid (n=5) and hyperthyroid (n=11) subjects. Iodine and peripheral T4 metabolims were measured with oral /sup 131/I-NaI and intravenous /sup 125/I-74 respectively. Data (obtained over 10 days) and kinetic model are analyzed using the SAAM27 program developed by Berman (1978). Compartment rate constants (mean rate per hour +- ISD) are tabulated in this paper. Thyroid and renal iodide clearance compare favorably with values reported in the literature. TYR rate constants were not unique; however, values obtained are within the range of rate constants determined from the invitro data reported by others. Intraluminal iodine as coupled TYR is predicted to be 21% for euthyroid and 59% for hyperthyroid subjects compared to analytical chemical methods of 30% and 51% respectively determined elsewhere. The authors plan to evaluate this model as a method of predicting the thyroid radiation dose from orally administered I/sup 131/

  15. A single Markov-type kinetic model accounting for the macroscopic currents of all human voltage-gated sodium channel isoforms.

    Science.gov (United States)

    Balbi, Pietro; Massobrio, Paolo; Hellgren Kotaleski, Jeanette

    2017-09-01

    Modelling ionic channels represents a fundamental step towards developing biologically detailed neuron models. Until recently, the voltage-gated ion channels have been mainly modelled according to the formalism introduced by the seminal works of Hodgkin and Huxley (HH). However, following the continuing achievements in the biophysical and molecular comprehension of these pore-forming transmembrane proteins, the HH formalism turned out to carry limitations and inconsistencies in reproducing the ion-channels electrophysiological behaviour. At the same time, Markov-type kinetic models have been increasingly proven to successfully replicate both the electrophysiological and biophysical features of different ion channels. However, in order to model even the finest non-conducting molecular conformational change, they are often equipped with a considerable number of states and related transitions, which make them computationally heavy and less suitable for implementation in conductance-based neurons and large networks of those. In this purely modelling study we develop a Markov-type kinetic model for all human voltage-gated sodium channels (VGSCs). The model framework is detailed, unifying (i.e., it accounts for all ion-channel isoforms) and computationally efficient (i.e. with a minimal set of states and transitions). The electrophysiological data to be modelled are gathered from previously published studies on whole-cell patch-clamp experiments in mammalian cell lines heterologously expressing the human VGSC subtypes (from NaV1.1 to NaV1.9). By adopting a minimum sequence of states, and using the same state diagram for all the distinct isoforms, the model ensures the lightest computational load when used in neuron models and neural networks of increasing complexity. The transitions between the states are described by original ordinary differential equations, which represent the rate of the state transitions as a function of voltage (i.e., membrane potential). The

  16. Development of Pneumatic Robot Hand and Construction of Master-Slave System

    Science.gov (United States)

    Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori

    Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.

  17. Complementary Hand Responses Occur in Both Peri- and Extrapersonal Space.

    Directory of Open Access Journals (Sweden)

    Tim W Faber

    Full Text Available Human beings have a strong tendency to imitate. Evidence from motor priming paradigms suggests that people automatically tend to imitate observed actions such as hand gestures by performing mirror-congruent movements (e.g., lifting one's right finger upon observing a left finger movement; from a mirror perspective. Many observed actions however, do not require mirror-congruent responses but afford complementary (fitting responses instead (e.g., handing over a cup; shaking hands. Crucially, whereas mirror-congruent responses don't require physical interaction with another person, complementary actions often do. Given that most experiments studying motor priming have used stimuli devoid of contextual information, this space or interaction-dependency of complementary responses has not yet been assessed. To address this issue, we let participants perform a task in which they had to mirror or complement a hand gesture (fist or open hand performed by an actor depicted either within or outside of reach. In three studies, we observed faster reaction times and less response errors for complementary relative to mirrored hand movements in response to open hand gestures (i.e., 'hand-shaking' irrespective of the perceived interpersonal distance of the actor. This complementary effect could not be accounted for by a low-level spatial cueing effect. These results demonstrate that humans have a strong and automatic tendency to respond by performing complementary actions. In addition, our findings underline the limitations of manipulations of space in modulating effects of motor priming and the perception of affordances.

  18. Complementary Hand Responses Occur in Both Peri- and Extrapersonal Space.

    Science.gov (United States)

    Faber, Tim W; van Elk, Michiel; Jonas, Kai J

    2016-01-01

    Human beings have a strong tendency to imitate. Evidence from motor priming paradigms suggests that people automatically tend to imitate observed actions such as hand gestures by performing mirror-congruent movements (e.g., lifting one's right finger upon observing a left finger movement; from a mirror perspective). Many observed actions however, do not require mirror-congruent responses but afford complementary (fitting) responses instead (e.g., handing over a cup; shaking hands). Crucially, whereas mirror-congruent responses don't require physical interaction with another person, complementary actions often do. Given that most experiments studying motor priming have used stimuli devoid of contextual information, this space or interaction-dependency of complementary responses has not yet been assessed. To address this issue, we let participants perform a task in which they had to mirror or complement a hand gesture (fist or open hand) performed by an actor depicted either within or outside of reach. In three studies, we observed faster reaction times and less response errors for complementary relative to mirrored hand movements in response to open hand gestures (i.e., 'hand-shaking') irrespective of the perceived interpersonal distance of the actor. This complementary effect could not be accounted for by a low-level spatial cueing effect. These results demonstrate that humans have a strong and automatic tendency to respond by performing complementary actions. In addition, our findings underline the limitations of manipulations of space in modulating effects of motor priming and the perception of affordances.

  19. Saturation mechanism of decaying ion temperature gradient driven turbulence with kinetic electrons

    International Nuclear Information System (INIS)

    Idomura, Yasuhiro

    2016-01-01

    We present full-f gyrokinetic simulations of the ion temperature gradient driven (ITG) turbulence including kinetic electrons. By comparing decaying ITG turbulence simulations with adiabatic and kinetic electron models, an impact of kinetic electrons on the ITG turbulence is investigated. It is found that significant electron transport occurs even in the ITG turbulence, and both ion and electron temperature profiles are relaxed. In steady states, both cases show upshifts of nonlinear critical ion temperature gradients from linear ones, while their saturation mechanisms are qualitatively different. In the adiabatic electron case, the ITG mode is stabilized by turbulence driven zonal flows. On the other hand, in the kinetic electron case, passing electrons transport shows fine resonant structures at mode rational surfaces, which generate corrugated density profiles. Such corrugated density profiles lead to fine radial electric fields following the neoclassical force balance relation. The resulting E × B shearing rate greatly exceeds the linear growth rate of the ITG mode. (author)

  20. Hand dominance in orthopaedic surgeons.

    LENUS (Irish Health Repository)

    Lui, Darren F

    2012-08-01

    Handedness is perhaps the most studied human asymmetry. Laterality is the preference shown for one side and it has been studied in many aspects of medicine. Studies have shown that some orthopaedic procedures had poorer outcomes and identified laterality as a contributing factor. We developed a questionnaire to assess laterality in orthopaedic surgery and compared this to an established scoring system. Sixty-two orthopaedic surgeons surveyed with the validated Waterloo Handedness Questionnaire (WHQ) were compared with the self developed Orthopaedic Handedness Questionnaire (OHQ). Fifty-eight were found to be right hand dominant (RHD) and 4 left hand dominant (LHD). In RHD surgeons, the average WHQ score was 44.9% and OHQ 15%. For LHD surgeons the WHQ score was 30.2% and OHQ 9.4%. This represents a significant amount of time using the non dominant hand but does not necessarily determine satisfactory or successful dexterity transferable to the operating room. Training may be required for the non dominant side.

  1. Diagnostic imaging of the hand

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Rainer [Hospital for Cardiovascular Diseases, Bad Neustadt an der Saale (Germany). Dept. of Radiology; Lanz, Ulrich [Perlach Hospital, Munich (Germany). Dept. of Hand Surgery

    2008-07-01

    With its complex anatomy and specialized biomechanics, the human hand has always presented physicians with a unique challenge when it comes to diagnosing and treating the diseases that afflict it. And while recent decades have seen a rapid increase in the number of therapeutic options, many diseases and injuries of the hand are still commonly misinterpreted. In diagnostic imaging of the hand, an interdisciplinary team, comprisingspecialists in radiology, surgery, and rheumatology, presents a comprehensive,reliable guide to this topographically intricate area. Highlights include: - More than 1000 high-quality illustrations - All state-of-the-art imaging modalities-including multidetector CT, with 2D displays and 3D reconstructions, and contrast-enhanced MRI with multi-channel, phased-array coils - An overview of all currently used methods of examination - A detailed presentation of the anatomic and functional foundations necessary for diagnosis - Full coverage of all disorders of the hand - Systematic treatment of each disease's definition, pathogenesis, and clinical symptoms, according to a graduated diagnostic plan - Easy-to-use format, featuring crisp images and line drawings seamlessly integrated with concise text, summary tables, and handy checklists - A heavily cross-referenced appendix of differential diagnosis tables - Emphasis on interdisciplinary consultation throughout designed to help both radiologists and clinicians develop the most efficient and effective strategies for evaluating and treating patients, Diagnostic imaging of the hand will leave specialists of all levels with a fresh appreciation for - and a richer understanding of - the expanding array of cutting-edge alternatives for diagnosing and treating disorders of the hand. (orig.)

  2. Diagnostic imaging of the hand

    International Nuclear Information System (INIS)

    Schmitt, Rainer; Lanz, Ulrich

    2008-01-01

    With its complex anatomy and specialized biomechanics, the human hand has always presented physicians with a unique challenge when it comes to diagnosing and treating the diseases that afflict it. And while recent decades have seen a rapid increase in the number of therapeutic options, many diseases and injuries of the hand are still commonly misinterpreted. In diagnostic imaging of the hand, an interdisciplinary team, comprisingspecialists in radiology, surgery, and rheumatology, presents a comprehensive,reliable guide to this topographically intricate area. Highlights include: - More than 1000 high-quality illustrations - All state-of-the-art imaging modalities-including multidetector CT, with 2D displays and 3D reconstructions, and contrast-enhanced MRI with multi-channel, phased-array coils - An overview of all currently used methods of examination - A detailed presentation of the anatomic and functional foundations necessary for diagnosis - Full coverage of all disorders of the hand - Systematic treatment of each disease's definition, pathogenesis, and clinical symptoms, according to a graduated diagnostic plan - Easy-to-use format, featuring crisp images and line drawings seamlessly integrated with concise text, summary tables, and handy checklists - A heavily cross-referenced appendix of differential diagnosis tables - Emphasis on interdisciplinary consultation throughout designed to help both radiologists and clinicians develop the most efficient and effective strategies for evaluating and treating patients, Diagnostic imaging of the hand will leave specialists of all levels with a fresh appreciation for - and a richer understanding of - the expanding array of cutting-edge alternatives for diagnosing and treating disorders of the hand. (orig.)

  3. Performance Comparison Between FEDERICA Hand and LARM Hand

    OpenAIRE

    Carbone, Giuseppe; Rossi, Cesare; Savino, Sergio

    2015-01-01

    This paper describes two robotic hands that have been\\ud developed at University Federico II of Naples and at the\\ud University of Cassino. FEDERICA Hand and LARM Hand\\ud are described in terms of design and operational features.\\ud In particular, careful attention is paid to the differences\\ud between the above-mentioned hands in terms of transmission\\ud systems. FEDERICA Hand uses tendons and pulleys\\ud to drive phalanxes, while LARM Hand uses cross four-bar\\ud linkages. Results of experime...

  4. Vision-Based Pose Estimation for Robot-Mediated Hand Telerehabilitation

    Directory of Open Access Journals (Sweden)

    Giuseppe Airò Farulla

    2016-02-01

    Full Text Available Vision-based Pose Estimation (VPE represents a non-invasive solution to allow a smooth and natural interaction between a human user and a robotic system, without requiring complex calibration procedures. Moreover, VPE interfaces are gaining momentum as they are highly intuitive, such that they can be used from untrained personnel (e.g., a generic caregiver even in delicate tasks as rehabilitation exercises. In this paper, we present a novel master–slave setup for hand telerehabilitation with an intuitive and simple interface for remote control of a wearable hand exoskeleton, named HX. While performing rehabilitative exercises, the master unit evaluates the 3D position of a human operator’s hand joints in real-time using only a RGB-D camera, and commands remotely the slave exoskeleton. Within the slave unit, the exoskeleton replicates hand movements and an external grip sensor records interaction forces, that are fed back to the operator-therapist, allowing a direct real-time assessment of the rehabilitative task. Experimental data collected with an operator and six volunteers are provided to show the feasibility of the proposed system and its performances. The results demonstrate that, leveraging on our system, the operator was able to directly control volunteers’ hands movements.

  5. Back to basics: hand hygiene and surgical hand antisepsis.

    Science.gov (United States)

    Spruce, Lisa

    2013-11-01

    Health care-associated infections (HAIs) are a significant issue in the United States and throughout the world, but following proper hand hygiene practices is the most effective and least expensive way to prevent HAIs. Hand hygiene is inexpensive and protects patients and health care personnel alike. The four general types of hand hygiene that should be performed in the perioperative environment are washing hands that are visibly soiled, hand hygiene using alcohol-based products, surgical hand scrubs, and surgical hand scrubs using an alcohol-based surgical hand rub product. Barriers to proper hand hygiene may include not thinking about it, forgetting, skin irritation, a lack of role models, or a lack of a safety culture. One strategy for improving hand hygiene practices is monitoring hand hygiene as part of a quality improvement project, but the most important aspect for perioperative team members is to set an example for other team members by following proper hand hygiene practices and reminding each other to perform hand hygiene. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. Kinetic compartmental analysis of carnitine metabolism in the human carnitine deficiency syndromes. Evidence for alterations in tissue carnitine transport.

    OpenAIRE

    Rebouche, C J; Engel, A G

    1984-01-01

    The human primary carnitine deficiency syndromes are potentially fatal disorders affecting children and adults. The molecular etiologies of these syndromes have not been determined. In this investigation, we considered the hypothesis that these syndromes result from defective transport of carnitine into tissues, particularly skeletal muscle. The problem was approached by mathematical modeling, by using the technique of kinetic compartmental analysis. A tracer dose of L-[methyl-3H]carnitine wa...

  7. Kinetic and Thermodynamic Rationale for SAHA Being a Preferential Human HDAC8 Inhibitor as Compared to the Structurally Similar Ligand, TSA

    Science.gov (United States)

    Singh, Raushan K.; Lall, Naveena; Leedahl, Travis S.; McGillivray, Abigail; Mandal, Tanmay; Haldar, Manas; Mallik, Sanku; Cook, Gregory; Srivastava, D.K.

    2013-01-01

    Of the different hydroxamate-based histone deacetylase (HDAC) inhibitors, Suberoylanilide hydroxamic acid (SAHA) has been approved by the FDA for treatment of T-cell lymphoma. Interestingly, a structurally similar inhibitor, Trichostatin A (TSA), which has a higher in vitro inhibitory-potency against HDAC8, reportedly shows a poor efficacy in clinical settings. In order to gain the molecular insight into the above discriminatory feature, we performed transient kinetic and isothermal titration calorimetric studies for the interaction of SAHA and TSA to the recombinant form of human HDAC8. The transient kinetic data revealed that the binding of both the inhibitors to the enzyme showed the biphasic profiles, which represented an initial encounter of enzyme with the inhibitor followed by the isomerization of the transient enzyme-inhibitor complexes. The temperature-dependent transient kinetic studies with the above inhibitors revealed that the bimolecular process is primarily dominated by favorable enthalpic changes, as opposed to the isomerization step; which is solely contributed by entropic changes. The standard binding-enthalpy (ΔH0) of SAHA, deduced from the transient kinetic as well as the isothermal titration calorimetric experiments, was 2–3 kcal/mol higher as compared to TSA. The experimental data presented herein suggests that SAHA serves as a preferential (target-specific/selective) HDAC8 inhibitor as compared to TSA. Arguments are presented that the detailed kinetic and thermodynamic studies may guide in the rational design of HDAC inhibitors as therapeutic agents. PMID:24079912

  8. Hand1 overexpression inhibits medulloblastoma metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Asuthkar, Swapna; Guda, Maheedhara R. [Department of Cancer Biology and Pharmacology, University of Illinois College of Medicine at Peoria, Peoria, IL 61656 (United States); Martin, Sarah E. [Department of Pathology, University of Illinois College of Medicine at Peoria, Peoria, IL 61656 (United States); Antony, Reuben; Fernandez, Karen [Department of Pediatrics, University of Illinois College of Medicine at Peoria, Peoria, IL 61656 (United States); Lin, Julian [Department of Neurosurgery, University of Illinois College of Medicine at Peoria, Peoria, IL 61656 (United States); Tsung, Andrew J. [Department of Cancer Biology and Pharmacology, University of Illinois College of Medicine at Peoria, Peoria, IL 61656 (United States); Department of Neurosurgery, University of Illinois College of Medicine at Peoria, Peoria, IL 61656 (United States); Illinois Neurological Institute, Peoria, IL 61656 (United States); Velpula, Kiran K., E-mail: velpula@uic.edu [Department of Cancer Biology and Pharmacology, University of Illinois College of Medicine at Peoria, Peoria, IL 61656 (United States); Department of Neurosurgery, University of Illinois College of Medicine at Peoria, Peoria, IL 61656 (United States)

    2016-08-19

    Medulloblastoma (MB) is the most frequent malignant pediatric brain tumor. Current treatment includes surgery, radiation and chemotherapy. However, ongoing treatment in patients is further classified according to the presence or absence of metastasis. Since metastatic medulloblastoma are refractory to current treatments, there is need to identify novel biomarkers that could be used to reduce metastatic potential, and more importantly be targeted therapeutically. Previously, we showed that ionizing radiation-induced uPAR overexpression is associated with increased accumulation of β-catenin in the nucleus. We further demonstrated that uPAR protein act as cytoplasmic sequestration factor for a novel basic helix-loop-helix transcription factor, Hand1. Among the histological subtypes classical and desmoplastic subtypes account for the majority while large cell/anaplastic variant is most commonly associated with metastatic disease. In this present study using immunohistochemical approach and patient data mining for the first time, we demonstrated that Hand1 expression is observed to be downregulated in all the subtypes of medulloblastoma. Previously we showed that Hand1 overexpression regulated medulloblastoma angiogenesis and here we investigated the role of Hand1 in the context of Epithelial-Mesenchymal Transition (EMT). Moreover, UW228 and D283 cells overexpressing Hand1 demonstrated decreased-expression of mesenchymal markers (N-cadherin, β-catenin and SOX2); metastatic marker (SMA); and increased expression of epithelial marker (E-cadherin). Strikingly, human pluripotent stem cell antibody array showed that Hand1 overexpression resulted in substantial decrease in pluripotency markers (Nanog, Oct3/4, Otx2, Flk1) suggesting that Hand1 expression may be essential to attenuate the EMT and our findings underscore a novel role for Hand1 in medulloblastoma metastasis. - Highlights: • Hand1 expression is downregulated in Medulloblastoma. • Hand1 over expression reduce

  9. Hand1 overexpression inhibits medulloblastoma metastasis

    International Nuclear Information System (INIS)

    Asuthkar, Swapna; Guda, Maheedhara R.; Martin, Sarah E.; Antony, Reuben; Fernandez, Karen; Lin, Julian; Tsung, Andrew J.; Velpula, Kiran K.

    2016-01-01

    Medulloblastoma (MB) is the most frequent malignant pediatric brain tumor. Current treatment includes surgery, radiation and chemotherapy. However, ongoing treatment in patients is further classified according to the presence or absence of metastasis. Since metastatic medulloblastoma are refractory to current treatments, there is need to identify novel biomarkers that could be used to reduce metastatic potential, and more importantly be targeted therapeutically. Previously, we showed that ionizing radiation-induced uPAR overexpression is associated with increased accumulation of β-catenin in the nucleus. We further demonstrated that uPAR protein act as cytoplasmic sequestration factor for a novel basic helix-loop-helix transcription factor, Hand1. Among the histological subtypes classical and desmoplastic subtypes account for the majority while large cell/anaplastic variant is most commonly associated with metastatic disease. In this present study using immunohistochemical approach and patient data mining for the first time, we demonstrated that Hand1 expression is observed to be downregulated in all the subtypes of medulloblastoma. Previously we showed that Hand1 overexpression regulated medulloblastoma angiogenesis and here we investigated the role of Hand1 in the context of Epithelial-Mesenchymal Transition (EMT). Moreover, UW228 and D283 cells overexpressing Hand1 demonstrated decreased-expression of mesenchymal markers (N-cadherin, β-catenin and SOX2); metastatic marker (SMA); and increased expression of epithelial marker (E-cadherin). Strikingly, human pluripotent stem cell antibody array showed that Hand1 overexpression resulted in substantial decrease in pluripotency markers (Nanog, Oct3/4, Otx2, Flk1) suggesting that Hand1 expression may be essential to attenuate the EMT and our findings underscore a novel role for Hand1 in medulloblastoma metastasis. - Highlights: • Hand1 expression is downregulated in Medulloblastoma. • Hand1 over expression reduce

  10. Stiff Hands

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Stiff Hands Email to a friend * required fields ...

  11. Hand Infections

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Hand Infections Email to a friend * required fields ...

  12. Hand hygiene compliance rates: Fact or fiction?

    Science.gov (United States)

    McLaws, Mary-Louise; Kwok, Yen Lee Angela

    2018-05-16

    The mandatory national hand hygiene program requires Australian public hospitals to use direct human auditing to establish compliance rates. To establish the magnitude of the Hawthorne effect, we compared direct human audit rates with concurrent automated surveillance rates. A large tertiary Australian teaching hospital previously trialed automated surveillance while simultaneously performing mandatory human audits for 20 minutes daily on a medical and a surgical ward. Subtracting automated surveillance rates from human audit rates provided differences in percentage points (PPs) for each of the 3 quarterly reporting periods for 2014 and 2015. Direct human audit rates for the medical ward were inflated by an average of 55 PPs in 2014 and 64 PPs in 2015, 2.8-3.1 times higher than automated surveillance rates. The rates for the surgical ward were inflated by an average of 32 PPs in 2014 and 31 PPs in 2015, 1.6 times higher than automated surveillance rates. Over the 6 mandatory reporting quarters, human audits collected an average of 255 opportunities, whereas automation collected 578 times more data, averaging 147,308 opportunities per quarter. The magnitude of the Hawthorne effect on direct human auditing was not trivial and produced highly inflated compliance rates. Mandatory compliance necessitates accuracy that only automated surveillance can achieve, whereas daily hand hygiene ambassadors or reminder technology could harness clinicians' ability to hyperrespond to produce habitual compliance. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  13. Earlier and greater hand pre-shaping in the elderly: a study based on kinematic analysis of reaching movements to grasp objects.

    Science.gov (United States)

    Tamaru, Yoshiki; Naito, Yasuo; Nishikawa, Takashi

    2017-11-01

    Elderly people are less able to manipulate objects skilfully than young adults. Although previous studies have examined age-related deterioration of hand movements with a focus on the phase after grasping objects, the changes in the reaching phase have not been studied thus far. We aimed to examine whether changes in hand shape patterns during the reaching phase of grasping movements differ between young adults and the elderly. Ten healthy elderly adults and 10 healthy young adults were examined using the Simple Test for Evaluating Hand Functions and kinetic analysis of hand pre-shaping reach-to-grasp tasks. The results were then compared between the two groups. For kinetic analysis, we measured the time of peak tangential velocity of the wrist and the inter-fingertip distance (the distance between the tips of the thumb and index finger) at different time points. The results showed that the elderly group's performance on the Simple Test for Evaluating Hand Functions was significantly lower than that of the young adult group, irrespective of whether the dominant or non-dominant hand was used, indicating deterioration of hand movement in the elderly. The peak tangential velocity of the wrist in either hand appeared significantly earlier in the elderly group than in the young adult group. The elderly group also showed larger inter-fingertip distances with arch-like fingertip trajectories compared to the young adult group for all object sizes. To perform accurate prehension, elderly people have an earlier peak tangential velocity point than young adults. This allows for a longer adjustment time for reaching and grasping movements and for reducing errors in object prehension by opening the hand and fingers wider. Elderly individuals gradually modify their strategy based on previous successes and failures during daily living to compensate for their decline in dexterity and operational capabilities. © 2017 Japanese Psychogeriatric Society.

  14. A new model of 18F-fluoride kinetics in humans. Simulation by analogue computer

    International Nuclear Information System (INIS)

    Charkes, N.D.; Philips, C.M.

    1977-01-01

    The authors have developed a 5-compartment model of short-term fluoride bone kinetics in adult humans which fits published observations made on plasma concentration, bone uptake and urinary excretion. The compartments are physiologically meaningful. When changes were simulated in systemic blood flow, a logarithmic relationship was found between early bone uptake and flow over a limited range of flows, but no simple relationship 1-2 hours after injection, when scans are usually made. Bone appears to behave as if it were almost saturated with fluoride at that time. The authors' observations are at variance with certain of the theoretical requirements for measuring skeletal blood flow by the extraction method and suggest that measurements made in the past may have been erroneous. (author)

  15. Controller design for Robotic hand through Electroencephalogram

    Directory of Open Access Journals (Sweden)

    Pandelidis P.

    2016-01-01

    Full Text Available - This paper deals with the designing, the construction and the control of a robotic hand via an electroencephalogram sensor. First a robotic device that is able to mimic a real human hand is constructed. A PID controller is designed in order to improve the performance of the robotic arm for grabbing objects. Furthermore, a novel design approach is presented for controlling the motion of the robotic arm using signals produced from an innovative electroencephalogram sensor that detects the concentration of the brain

  16. Kinetics, Reaction Orders, Rate Laws, and Their Relation to Mechanisms: A Hands-On Introduction for High School Students Using Portable Spectrophotometry

    Science.gov (United States)

    Carraher, Jack M.; Curry, Sarah M.; Tessonnier, Jean-Philippe

    2016-01-01

    Teaching complex chemistry concepts such as kinetics using inquiry-based learning techniques can be challenging in a high school classroom setting. Access to expensive laboratory equipment such as spectrometers is typically limited and most reaction kinetics experiments have been designed for advanced placement (AP) or first-year undergraduate…

  17. Pilot evaluation of a ward-based automated hand hygiene training system.

    Science.gov (United States)

    Ghosh, Anarta; Ameling, Stefan; Zhou, Jiang; Lacey, Gerard; Creamer, Eilish; Dolan, Anthony; Sherlock, Orla; Humphreys, Hilary

    2013-04-01

    A novel artificial intelligence (AI) system (SureWash; GLANTA, Dublin, Ireland) was placed on a ward with 45 staff members for two 6-day periods to automatically assess hand hygiene technique and the potential effectiveness of the automated training system. Two human reviewers assessed videos from 50 hand hygiene events with an interrater reliability (IIR) of 88% (44/50). The IIR was 88% (44/50) for the human reviewers and 80% (40/50) for the software. This study also investigated the poses missed and the impact of feedback on participation (+113%), duration (+11%), and technique (+2.23%). Our findings showed significant correlation between the human raters and the computer, demonstrating for the first time in a clinical setting the potential use of this type of AI technology in hand hygiene training. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Kinetic Analysis of the Bypass of a Bulky DNA Lesion Catalyzed by Human Y-family DNA Polymerases

    Science.gov (United States)

    Sherrer, Shanen M.; Sanman, Laura E.; Xia, Cynthia X.; Bolin, Eric R.; Malik, Chanchal K.; Efthimiopoulos, Georgia; Basu, Ashis K.; Suo, Zucai

    2012-01-01

    1-Nitropyrene (1-NP), a mutagen and potential carcinogen, is the most abundant nitro polyaromatic hydrocarbon in diesel exhaust, which reacts with DNA to form predominantly N-(deoxyguanosin-8-yl)-1-aminopyrene (dGAP). If not repaired, this DNA lesion is presumably bypassed in vivo by any of human Y-family DNA polymerases kappa (hPolκ), iota (hPolτ), eta (hPolη), and Rev1 (hRev1). Our running start assays demonstrated that each of these enzymes was indeed capable of traversing a site-specifically placed dGAP on a synthetic DNA template but hRev1 was stopped after lesion bypass. The time required to bypass 50% of the dGAP sites (t50bypass ) encountered by hPolη, hPolκ and hPolτ was determined to be 2.5 s, 4.1 s, and 106.5 s, respectively. The efficiency order of catalyzing translesion synthesis of dGAP (hPolη > hPolκ > hPolτ >> hRev1) is the same as the order for these human Y-family enzymes to elongate undamaged DNA. Although hPolη bypassed dGAP efficiently, replication by both hPolκ and hPolτ was strongly stalled at the lesion site and at a site immediately downstream from dGAP. By employing pre-steady state kinetic methods, a kinetic basis was established for polymerase pausing at these DNA template sites. Besides efficiency of bypass, the fidelity of those low-fidelity polymerases at these pause sites was also significantly decreased. Thus, if the translesion DNA synthesis of dGAP in vivo is catalyzed by a human Y-family DNA polymerase, e.g. hPolη, the process is certainly mutagenic. PMID:22324639

  19. Biomimetic actuator and sensor for robot hand

    International Nuclear Information System (INIS)

    Kim, Baekchul; Chung, Jinah; Cho, Hanjoung; Shin, Seunghoon; Lee, Hyoungsuk; Moon, Hyungpil; Choi, Hyouk Ryeol; Koo, Jachoon

    2012-01-01

    To manufacture a robot hand that essentially mimics the functions of a human hand, it is necessary to develop flexible actuators and sensors. In this study, we propose the design, manufacture, and performance verification of flexible actuators and sensors based on Electro Active Polymer (EAP). EAP is fabricated as a type of film, and it moves with changes in the voltage because of contraction and expansion in the polymer film. Furthermore, if a force is applied to an EAP film, its thickness and effective area change, and therefore, the capacitance also changes. By using this mechanism, we produce capacitive actuators and sensors. In this study, we propose an EAP based capacitive sensor and evaluate its use as a robot hand sensor

  20. Biomimetic actuator and sensor for robot hand

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Baekchul; Chung, Jinah; Cho, Hanjoung; Shin, Seunghoon; Lee, Hyoungsuk; Moon, Hyungpil; Choi, Hyouk Ryeol; Koo, Jachoon [Sungkyunkwan Univ., Seoul (Korea, Republic of)

    2012-12-15

    To manufacture a robot hand that essentially mimics the functions of a human hand, it is necessary to develop flexible actuators and sensors. In this study, we propose the design, manufacture, and performance verification of flexible actuators and sensors based on Electro Active Polymer (EAP). EAP is fabricated as a type of film, and it moves with changes in the voltage because of contraction and expansion in the polymer film. Furthermore, if a force is applied to an EAP film, its thickness and effective area change, and therefore, the capacitance also changes. By using this mechanism, we produce capacitive actuators and sensors. In this study, we propose an EAP based capacitive sensor and evaluate its use as a robot hand sensor.

  1. A preliminary study for non-invasive quantification of manganese in human hand bones

    International Nuclear Information System (INIS)

    Aslam; Pejovic-Milic, A; Chettle, D R; McNeill, F E; Pysklywec, M W; Oudyk, J

    2008-01-01

    Manganese (Mn) is a nutrient essential for regulating neurological and skeletal functions in the human body, but it is also toxic when humans are excessively exposed to Mn. Blood (or serum/plasma) and other body fluids reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive measurement of Mn stored in bone, using in vivo neutron activation analysis. Following feasibility studies, a first pilot study, using neutron activation analysis to measure Mn in the bones of the hand of ten healthy male human subjects, was conducted with the approval of the concerned research ethics boards. The participants of this study had no known history of exposure to Mn. Two volunteers were excluded from this study due to technical problems with their measurements. The inverse variance weighted mean value of Mn/Ca for the participants of this study is 0.12 ± 0.68 μg Mn/g Ca which is comparable within uncertainties with the estimated range of 0.16-0.78 μg Mn/g Ca and mean value of 0.63 ± 0.30 μg Mn/g Ca derived from cadaver data. It is recommended to investigate the use of the diagnostic technique for in vivo measurements of workers exposed occupationally to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. The technique needs further development to improve the precision of in vivo measurements in the non-exposed population. (note)

  2. Enrichment of tumor cells for cell kinetic analysis in human tumor biopsies using cytokeratin gating

    International Nuclear Information System (INIS)

    Haustermans, K.; Hofland, I.; Ramaekers, M.; Ivanyi, D.; Balm, A.J.M.; Geboes, K.; Lerut, T.; Schueren, E. van der; Begg, A.C.

    1996-01-01

    Purpose: To determine the feasibility of using cytokeratin antibodies to distinguish normal and malignant cells in human tumors using flow cytometry. The goal was ultimately to increase the accuracy of cell kinetic measurements on human tumor biopsies. Material and methods: A panel of four antibodies was screened on a series of 48 tumors from two centres; 22 head and neck tumors (Amsterdam) and 26 esophagus carcinomas (Leuven). First, screening was carried out by immunohistochemistry on frozen sections to test intensity of staining and the fraction of cytokeratin-positive tumor cells. The antibody showing the most positive staining was then used for flow cytometry on the same tumor. Results: The two broadest spectrum antibodies (AE1/AE3, E3/C4) showed overall the best results with immunohistochemical staining, being positive in over 95% of tumors. Good cell suspensions for DNA flow cytometry could be made from frozen material by a mechanical method, whereas enzymatic methods with trypsin or collagenase were judged failures in almost all cases. >From fresh material, both collagenase and trypsin produced good suspensions for flow cytometry, although the fraction of tumor cells, judged by proportion aneuploid cells, was markedly higher for trypsin. Using the best cytokeratin antibody for each tumor, two parameter flow cytometry was done (cytokeratin versus DNA content). Enrichment of tumor cells was then tested by measuring the fraction of aneuploid cells (the presumed malignant population) of cytokeratin-positive cells versus all cells. An enrichment factor ranging between 0 (no enrichment) and 1 (perfect enrichment, tumor cells only) was then calculated. The average enrichment was 0.60 for head and neck tumors and 0.59 for esophagus tumors. Conclusions: We conclude that this method can substantially enrich the proportion of tumor cells in biopsies from carcinomas. Application of this method could significantly enhance accuracy of tumor cell kinetic measurements

  3. Hand gesture recognition in confined spaces with partial observability and occultation constraints

    Science.gov (United States)

    Shirkhodaie, Amir; Chan, Alex; Hu, Shuowen

    2016-05-01

    Human activity detection and recognition capabilities have broad applications for military and homeland security. These tasks are very complicated, however, especially when multiple persons are performing concurrent activities in confined spaces that impose significant obstruction, occultation, and observability uncertainty. In this paper, our primary contribution is to present a dedicated taxonomy and kinematic ontology that are developed for in-vehicle group human activities (IVGA). Secondly, we describe a set of hand-observable patterns that represents certain IVGA examples. Thirdly, we propose two classifiers for hand gesture recognition and compare their performance individually and jointly. Finally, we present a variant of Hidden Markov Model for Bayesian tracking, recognition, and annotation of hand motions, which enables spatiotemporal inference to human group activity perception and understanding. To validate our approach, synthetic (graphical data from virtual environment) and real physical environment video imagery are employed to verify the performance of these hand gesture classifiers, while measuring their efficiency and effectiveness based on the proposed Hidden Markov Model for tracking and interpreting dynamic spatiotemporal IVGA scenarios.

  4. Hand Motion Classification Using a Multi-Channel Surface Electromyography Sensor

    Directory of Open Access Journals (Sweden)

    Dong Sun

    2012-01-01

    Full Text Available The human hand has multiple degrees of freedom (DOF for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  5. Hand motion classification using a multi-channel surface electromyography sensor.

    Science.gov (United States)

    Tang, Xueyan; Liu, Yunhui; Lv, Congyi; Sun, Dong

    2012-01-01

    The human hand has multiple degrees of freedom (DOF) for achieving high-dexterity motions. Identifying and replicating human hand motions are necessary to perform precise and delicate operations in many applications, such as haptic applications. Surface electromyography (sEMG) sensors are a low-cost method for identifying hand motions, in addition to the conventional methods that use data gloves and vision detection. The identification of multiple hand motions is challenging because the error rate typically increases significantly with the addition of more hand motions. Thus, the current study proposes two new methods for feature extraction to solve the problem above. The first method is the extraction of the energy ratio features in the time-domain, which are robust and invariant to motion forces and speeds for the same gesture. The second method is the extraction of the concordance correlation features that describe the relationship between every two channels of the multi-channel sEMG sensor system. The concordance correlation features of a multi-channel sEMG sensor system were shown to provide a vast amount of useful information for identification. Furthermore, a new cascaded-structure classifier is also proposed, in which 11 types of hand gestures can be identified accurately using the newly defined features. Experimental results show that the success rate for the identification of the 11 gestures is significantly high.

  6. Transient Kinetic Analysis of Hydrogen Sulfide Oxidation Catalyzed by Human Sulfide Quinone Oxidoreductase*

    Science.gov (United States)

    Mishanina, Tatiana V.; Yadav, Pramod K.; Ballou, David P.; Banerjee, Ruma

    2015-01-01

    The first step in the mitochondrial sulfide oxidation pathway is catalyzed by sulfide quinone oxidoreductase (SQR), which belongs to the family of flavoprotein disulfide oxidoreductases. During the catalytic cycle, the flavin cofactor is intermittently reduced by sulfide and oxidized by ubiquinone, linking H2S oxidation to the electron transfer chain and to energy metabolism. Human SQR can use multiple thiophilic acceptors, including sulfide, sulfite, and glutathione, to form as products, hydrodisulfide, thiosulfate, and glutathione persulfide, respectively. In this study, we have used transient kinetics to examine the mechanism of the flavin reductive half-reaction and have determined the redox potential of the bound flavin to be −123 ± 7 mV. We observe formation of an unusually intense charge-transfer (CT) complex when the enzyme is exposed to sulfide and unexpectedly, when it is exposed to sulfite. In the canonical reaction, sulfide serves as the sulfur donor and sulfite serves as the acceptor, forming thiosulfate. We show that thiosulfate is also formed when sulfide is added to the sulfite-induced CT intermediate, representing a new mechanism for thiosulfate formation. The CT complex is formed at a kinetically competent rate by reaction with sulfide but not with sulfite. Our study indicates that sulfide addition to the active site disulfide is preferred under normal turnover conditions. However, under pathological conditions when sulfite concentrations are high, sulfite could compete with sulfide for addition to the active site disulfide, leading to attenuation of SQR activity and to an alternate route for thiosulfate formation. PMID:26318450

  7. Transient Kinetic Analysis of Hydrogen Sulfide Oxidation Catalyzed by Human Sulfide Quinone Oxidoreductase.

    Science.gov (United States)

    Mishanina, Tatiana V; Yadav, Pramod K; Ballou, David P; Banerjee, Ruma

    2015-10-09

    The first step in the mitochondrial sulfide oxidation pathway is catalyzed by sulfide quinone oxidoreductase (SQR), which belongs to the family of flavoprotein disulfide oxidoreductases. During the catalytic cycle, the flavin cofactor is intermittently reduced by sulfide and oxidized by ubiquinone, linking H2S oxidation to the electron transfer chain and to energy metabolism. Human SQR can use multiple thiophilic acceptors, including sulfide, sulfite, and glutathione, to form as products, hydrodisulfide, thiosulfate, and glutathione persulfide, respectively. In this study, we have used transient kinetics to examine the mechanism of the flavin reductive half-reaction and have determined the redox potential of the bound flavin to be -123 ± 7 mV. We observe formation of an unusually intense charge-transfer (CT) complex when the enzyme is exposed to sulfide and unexpectedly, when it is exposed to sulfite. In the canonical reaction, sulfide serves as the sulfur donor and sulfite serves as the acceptor, forming thiosulfate. We show that thiosulfate is also formed when sulfide is added to the sulfite-induced CT intermediate, representing a new mechanism for thiosulfate formation. The CT complex is formed at a kinetically competent rate by reaction with sulfide but not with sulfite. Our study indicates that sulfide addition to the active site disulfide is preferred under normal turnover conditions. However, under pathological conditions when sulfite concentrations are high, sulfite could compete with sulfide for addition to the active site disulfide, leading to attenuation of SQR activity and to an alternate route for thiosulfate formation. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  8. Bipedal tool use strengthens chimpanzee hand preferences

    DEFF Research Database (Denmark)

    Braccini, Stephanie; Lambeth, Susan; Schapiro, Steve

    2010-01-01

    The degree to which non-human primate behavior is lateralized, at either individual or population levels, remains controversial. We investigated the relationship between hand preference and posture during tool use in chimpanzees (Pan troglodytes) during bipedal tool use. We experimentally induced...

  9. Electromyogram synergy control of a dexterous artificial hand to unscrew and screw objects.

    Science.gov (United States)

    Kent, Benjamin A; Karnati, Nareen; Engeberg, Erik D

    2014-03-21

    Due to their limited dexterity, it is currently not possible to use a commercially available prosthetic hand to unscrew or screw objects without using elbow and shoulder movements. For these tasks, prosthetic hands function like a wrench, which is unnatural and limits their use in tight working environments. Results from timed rotational tasks with human subjects demonstrate the clinical need for increased dexterity of prosthetic hands, and a clinically viable solution to this problem is presented for an anthropomorphic artificial hand. Initially, a human hand motion analysis was performed during a rotational task. From these data, human hand synergies were derived and mapped to an anthropomorphic artificial hand. The synergy for the artificial hand is controlled using conventional dual site electromyogram (EMG) signals. These EMG signals were mapped to the developed synergy to control four joints of the dexterous artificial hand simultaneously.Five limb absent and ten able-bodied test subjects participated in a comparison study to complete a timed rotational task as quickly as possible with their natural hands (except for one subject with a bilateral hand absence), eight commercially available prosthetic hands, and the proposed synergy controller. Each test subject used two to four different artificial hands. With the able-bodied subjects, the developed synergy controller reduced task completion time by 177% on average. The limb absent subjects completed the task faster on average than with their own prostheses by 46%. There was a statistically significant improvement in task completion time with the synergy controller for three of the four limb absent participants with integrated prostheses, and was not statistically different for the fourth. The proposed synergy controller reduced average task completion time compared to commercially available prostheses. Additionally, the synergy controller is able to function in a small workspace and requires less physical

  10. Kinetic modeling in pre-clinical positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuntner, Claudia [AIT Austrian Institute of Technology GmbH, Seibersdorf (Austria). Biomedical Systems, Health and Environment Dept.

    2014-07-01

    Pre-clinical positron emission tomography (PET) has evolved in the last few years from pure visualization of radiotracer uptake and distribution towards quantification of the physiological parameters. For reliable and reproducible quantification the kinetic modeling methods used to obtain relevant parameters of radiotracer tissue interaction are important. Here we present different kinetic modeling techniques with a focus on compartmental models including plasma input models and reference tissue input models. The experimental challenges of deriving the plasma input function in rodents and the effect of anesthesia are discussed. Finally, in vivo application of kinetic modeling in various areas of pre-clinical research is presented and compared to human data.

  11. Hand-related physical function in rheumatic hand conditions

    DEFF Research Database (Denmark)

    Klokker, Louise; Terwee, Caroline B; Wæhrens, Eva Ejlersen

    2016-01-01

    as well as those items from the Patient Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) item bank that are relevant to patients with rheumatic hand conditions. Selection will be based on consensus among reviewers. Content validity of selected items will be established......INTRODUCTION: There is no consensus about what constitutes the most appropriate patient-reported outcome measurement (PROM) instrument for measuring physical function in patients with rheumatic hand conditions. Existing instruments lack psychometric testing and vary in feasibility...... and their psychometric qualities. We aim to develop a PROM instrument to assess hand-related physical function in rheumatic hand conditions. METHODS AND ANALYSIS: We will perform a systematic search to identify existing PROMs to rheumatic hand conditions, and select items relevant for hand-related physical function...

  12. Hand-related physical function in rheumatic hand conditions

    DEFF Research Database (Denmark)

    Klokker, Louise; Terwee, Caroline; Wæhrens, Eva Elisabet Ejlersen

    2016-01-01

    INTRODUCTION: There is no consensus about what constitutes the most appropriate patient-reported outcome measurement (PROM) instrument for measuring physical function in patients with rheumatic hand conditions. Existing instruments lack psychometric testing and vary in feasibility...... and their psychometric qualities. We aim to develop a PROM instrument to assess hand-related physical function in rheumatic hand conditions. METHODS AND ANALYSIS: We will perform a systematic search to identify existing PROMs to rheumatic hand conditions, and select items relevant for hand-related physical function...... as well as those items from the Patient Reported Outcomes Measurement Information System (PROMIS) Physical Function (PF) item bank that are relevant to patients with rheumatic hand conditions. Selection will be based on consensus among reviewers. Content validity of selected items will be established...

  13. Hand Gesture Recognition Using Modified 1$ and Background Subtraction Algorithms

    Directory of Open Access Journals (Sweden)

    Hazem Khaled

    2015-01-01

    Full Text Available Computers and computerized machines have tremendously penetrated all aspects of our lives. This raises the importance of Human-Computer Interface (HCI. The common HCI techniques still rely on simple devices such as keyboard, mice, and joysticks, which are not enough to convoy the latest technology. Hand gesture has become one of the most important attractive alternatives to existing traditional HCI techniques. This paper proposes a new hand gesture detection system for Human-Computer Interaction using real-time video streaming. This is achieved by removing the background using average background algorithm and the 1$ algorithm for hand’s template matching. Then every hand gesture is translated to commands that can be used to control robot movements. The simulation results show that the proposed algorithm can achieve high detection rate and small recognition time under different light changes, scales, rotation, and background.

  14. The deep lymphatic anatomy of the hand.

    Science.gov (United States)

    Ma, Chuan-Xiang; Pan, Wei-Ren; Liu, Zhi-An; Zeng, Fan-Qiang; Qiu, Zhi-Qiang

    2018-04-03

    The deep lymphatic anatomy of the hand still remains the least described in medical literature. Eight hands were harvested from four nonembalmed human cadavers amputated above the wrist. A small amount of 6% hydrogen peroxide was employed to detect the lymphatic vessels around the superficial and deep palmar vascular arches, in webs from the index to little fingers, the thenar and hypothenar areas. A 30-gauge needle was inserted into the vessels and injected with a barium sulphate compound. Each specimen was dissected, photographed and radiographed to demonstrate deep lymphatic distribution of the hand. Five groups of deep collecting lymph vessels were found in the hand: superficial palmar arch lymph vessel (SPALV); deep palmar arch lymph vessel (DPALV); thenar lymph vessel (TLV); hypothenar lymph vessel (HTLV); deep finger web lymph vessel (DFWLV). Each group of vessels drained in different directions first, then all turned and ran towards the wrist in different layers. The deep lymphatic drainage of the hand has been presented. The results will provide an anatomical basis for clinical management, educational reference and scientific research. Copyright © 2018 Elsevier GmbH. All rights reserved.

  15. Rubber hand illusion induced by touching the face ipsilaterally to a deprived hand: evidence for plastic ‘somatotopic’ remapping in tetraplegics

    Directory of Open Access Journals (Sweden)

    Michele eScandola

    2014-06-01

    Full Text Available Background: Studies in animals and humans indicate that the interruption of body-brain connections following spinal cord injury (SCI leads to plastic cerebral reorganization.Objective: To explore whether inducing the Rubber Hand Illusion (RHI via synchronous multisensory visuo-tactile bodily stimulation may reveal any perceptual correlates of plastic remapping in SCI.Methods: In 16 paraplegic, 16 tetraplegic and 16 healthy participants we explored whether RHI may be induced by tactile stimuli involving not only the left hand but also the left hemi-face. Touching the participant’s actual hand or face was either synchronous or asynchronous with tactile stimuli seen on a rubber hand. We assessed two components of the illusion, namely perceived changes in the real hand in space (indexed by proprioceptive drift and ownership of the rubber hand (indexed by subjective responses to an ad-hoc questionnaire.Results: Proprioceptive drift and ownership were found in the healthy group only in the condition where the left real and fake hand were touched simultaneously. In contrast, no drift was found in the SCI patients who, however, showed ownership after both synchronous and asynchronous hand stroking. Importantly, only tetraplegics showed the effect also after synchronous face stroking. Conclusions: RHI may reveal plastic phenomena in SCI. In hand representation-deprived tetraplegics, stimuli on the face (represented contiguously in the somatic and motor systems, drive the sense of hand ownership. This hand-face remapping phenomenon may be useful for restoring a sense of self in massively deprived individuals.

  16. Design and control of five fingered under-actuated robotic hand

    Science.gov (United States)

    Sahoo, Biswojit; Parida, Pramod Kumar

    2018-04-01

    Now a day's research regarding humanoid robots and its application in different fields (industry, household, rehabilitation and exploratory) is going on entire the globe. Among which a challenging topic is to design a dexterous robotic hand which not only can perform as a hand of a robot but also can be used in re habilitation. The basic key concern is a dexterous robot hand which can be able to mimic the function of biological hand to perform different operations. This thesis work is regarding design and control of a under-actuated robotic hand consisting of four under actuated fingers (index finger, middle finger, little finger and ring finger ) , a thumb and a dexterous palm which can copy the motions and grasp type of human hand which having 21degrees of freedom instead of 25Degree Of Freedom.

  17. Compact Dexterous Robotic Hand

    Science.gov (United States)

    Lovchik, Christopher Scott (Inventor); Diftler, Myron A. (Inventor)

    2001-01-01

    A compact robotic hand includes a palm housing, a wrist section, and a forearm section. The palm housing supports a plurality of fingers and one or more movable palm members that cooperate with the fingers to grasp and/or release an object. Each flexible finger comprises a plurality of hingedly connected segments, including a proximal segment pivotally connected to the palm housing. The proximal finger segment includes at least one groove defining first and second cam surfaces for engagement with a cable. A plurality of lead screw assemblies each carried by the palm housing are supplied with power from a flexible shaft rotated by an actuator and output linear motion to a cable move a finger. The cable is secured within a respective groove and enables each finger to move between an opened and closed position. A decoupling assembly pivotally connected to a proximal finger segment enables a cable connected thereto to control movement of an intermediate and distal finger segment independent of movement of the proximal finger segment. The dexterous robotic hand closely resembles the function of a human hand yet is light weight and capable of grasping both heavy and light objects with a high degree of precision.

  18. Growth Kinetics of Rhodococcus Erythropolis IGTS8 on Thiophene and Dimethylsulphoxide

    International Nuclear Information System (INIS)

    El-Temtamy, S.A.; Farahat, L.A.; Al-Shatnawi, D.F.; AI-Sayed, S.

    2004-01-01

    Sulfur oxides emissions through fossil fuel combustion posse environmental problems because these oxides are major cause of acid rain, which dissolve buildings, kills forests and poisons lakes. That is why world environmental regulations are becoming harder with respect to sulfur content in fossil fuels. The demand for new low-cost desulfurization technologies has led to renewed interest in bio desulfurization. In this work the growth kinetics of Rhodococcus Erythopolis IGTS8 have been studied on two model sulfur compounds that are found among other sulfur compounds in petroleum fractions. These are namely thiophene and dimethyl sulfoxide, DEMSO. Batch reactor and different substrate concentrations ranging between 1 and 8 gl -1 were used to study the growth kinetics. Growth on thiophene was shown to follow Monode kinetics with μ m ax =0.064 h -1 and K s = 2.8 gl -1 , on the other hand, growth on DEMSO was found to be substrate inhibited

  19. Human health risk assessment of chloroxylenol in liquid hand soap and dishwashing soap used by consumers and health-care professionals.

    Science.gov (United States)

    Yost, Lisa J; Rodricks, Joseph D; Turnbull, Duncan; DeLeo, Paul C; Nash, J Frank; Quiñones-Rivera, Antonio; Carlson, Pete A

    2016-10-01

    A quantitative human risk assessment of chloroxylenol was conducted for liquid hand and dishwashing soap products used by consumers and health-care workers. The toxicological data for chloroxylenol indicate lack of genotoxicity, no evidence of carcinogenicity, and minimal systemic toxicity. No observed adverse effect levels (NOAEL) were established from chronic toxicity studies, specifically a carcinogenicity study that found no cancer excess (18 mg/kg-day) and studies of developmental and reproductive toxicity (100 mg/kg-day). Exposure to chloroxylenol for adults and children was estimated for two types of rinse-off cleaning products, one liquid hand soap, and two dishwashing products. The identified NOAELs were used together with exposure estimates to derive margin of exposure (MOE) estimates for chloroxylenol (i.e., estimates of exposure over NOAELs). These estimates were designed with conservative assumptions and likely overestimate exposure and risk (i.e., highest frequency, 100% dermal penetration). The resulting MOEs ranged from 178 to over 100, 000, 000 indicating negligibly small potential for harm related to consumer or health-care worker exposure to chloroxylenol in liquid soaps used in dish washing and hand washing. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. [Bacteriological study of oral cavity of people of Mexican origin to determine etiology agents of human infections in hand bite].

    Science.gov (United States)

    Cañedo-Guzmán, Cristhyan Baruch; Espinosa-Gutiérrez, Alejandro; Guzmán-Murillo, María Antonia

    2013-01-01

    Hand infections secondary to human bites often leave serious consequences on the functioning of the hand. Such infections are caused by different bacteria. Most bacteriological studies have been made to people of Anglo-Saxon origin or descent, and based on these findings; provide treatment to patients of different origins which may not always be as effective. Descriptive, internal stratified 17 patients were isolated samples of oral cavity and dental plaque bacterial species to identify and define the possible treatment according to the species identified. Microorganisms were isolated Gram (+) and Gram (-) belonging to the normal flora of the oral cavity and dental plaque in all the cases studied, presenting a variable number of microorganisms according to age but not by sex. The group of Gram-positive bacteria isolated showed sensitivity to: erythromycin, chloramphenicol and ciprofloxacin. In the group of Gram negative: kanamycin, amoxicillin + clavulanic acid, ciprofloxacin and norfloxacin, E. Corrodens sensitive to the group of quinolones as ciprofloxacin, norfloxacin as well as ceftriaxone and cefoperazone sulbactam. The bacterial species that are commonly found in normal flora of the oral cavity and dental plaque may be potential pathogens in a hand injury where to find the appropriate conditions for their development.

  1. Specification of jaw identity by the Hand2 transcription factor

    Science.gov (United States)

    Funato, Noriko; Kokubo, Hiroki; Nakamura, Masataka; Yanagisawa, Hiromi; Saga, Yumiko

    2016-01-01

    Acquisition of the lower jaw (mandible) was evolutionarily important for jawed vertebrates. In humans, syndromic craniofacial malformations often accompany jaw anomalies. The basic helix-loop-helix transcription factor Hand2, which is conserved among jawed vertebrates, is expressed in the neural crest in the mandibular process but not in the maxillary process of the first branchial arch. Here, we provide evidence that Hand2 is sufficient for upper jaw (maxilla)-to-mandible transformation by regulating the expression of homeobox transcription factors in mice. Altered Hand2 expression in the neural crest transformed the maxillae into mandibles with duplicated Meckel’s cartilage, which resulted in an absence of the secondary palate. In Hand2-overexpressing mutants, non-Hox homeobox transcription factors were dysregulated. These results suggest that Hand2 regulates mandibular development through downstream genes of Hand2 and is therefore a major determinant of jaw identity. Hand2 may have influenced the evolutionary acquisition of the mandible and secondary palate. PMID:27329940

  2. Substance P and Calcitonin gene-related peptide expression in human periodontal ligament after root canal preparation with Reciproc Blue, WaveOne Gold, XP EndoShaper and hand files.

    Science.gov (United States)

    Caviedes-Bucheli, J; Rios-Osorio, N; Rey-Rojas, M; Laguna-Rivero, F; Azuero-Holguin, M M; Diaz, L E; Curtidor, H; Castaneda-Ramirez, J J; Munoz, H R

    2018-05-17

    To quantify the Substance P (SP) and Calcitonin gene-related peptide (CGRP) expression in healthy human periodontal ligament from premolars after root canal preparation with Reciproc Blue, WaveOne Gold, XP EndoShaper and hand files. Fifty human periodontal ligament samples were obtained from healthy mandibular premolars where extraction was indicated for orthodontic reasons. Prior to extraction, 40 of these premolars were equally divided into four groups, and root canals were prepared using four different systems: Reciproc Blue, WaveOne Gold, XP EndoShaper, and a hand instrumentation technique. The remaining 10 healthy premolars were extracted without treatment and served as a negative control group. All periodontal ligament samples were processed, and SP and CGRP were measured by radioimmunoassay. The Kruskal-Wallis test was used to establish significant differences between groups and LSD post hoc comparisons were also performed. Greater SP and CGRP values were found in the hand instrumentation group, followed by the XP EndoShaper, WaveOne Gold and the Reciproc groups. The lower SP and CGRP values were for the healthy periodontal ligament group. The Kruskal-Wallis test revealed significant differences between groups (p 0.05). All the root canal preparation techniques tested increased SP and CGRP expression in human periodontal ligament, with hand files and XP EndoShaper instruments being associated with greater neuropeptide release compared to Reciproc Blue and WaveOne Gold files. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. Work fluctuation theorems and free energy from kinetic theory

    Science.gov (United States)

    Brey, J. Javier; Ruiz-Montero, M. J.; Domínguez, Álvaro

    2018-01-01

    The formulation of the first and second principles of thermodynamics for a particle in contact with a heat bath and submitted to an external force is analyzed, by means of the Boltzmann-Lorentz kinetic equation. The possible definitions of the thermodynamic quantities are discussed in the light of the H theorem verified by the distribution of the particle. The work fluctuation relations formulated by Bochkov and Kuzovlev, and by Jarzynski, respectively, are derived from the kinetic equation. In addition, particle simulations using both the direct simulation Monte Carlo method and molecular dynamics, are used to investigate the practical accuracy of the results. Work distributions are also measured, and they turn out to be rather complex. On the other hand, they seem to depend very little, if any, on the interaction potential between the intruder and the bath.

  4. The Treatment of Smith's Invisible Hand

    Science.gov (United States)

    Wight, Jonathan B.

    2007-01-01

    Adam Smith used the metaphor of an invisible hand to represent the instincts of human nature that direct behavior. Moderated by self-control and guided by proper institutional incentives, actions grounded in instincts can be shown to generate a beneficial social order even if not intended. Smith's concept, however, has been diluted and distorted…

  5. Hand Fractures

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... DESCRIPTION The bones of the hand serve as a framework. This framework supports the muscles that make the wrist and fingers move. When ...

  6. Development of anthropomorphic robotic hand driven by Pneumatic Artificial Muscles for robotic applications

    Science.gov (United States)

    Farag, Mohannad; Zainul Azlan, Norsinnira; Hayyan Alsibai, Mohammed

    2018-04-01

    This paper presents the design and fabrication of a three-fingered anthropomorphic robotic hand. The fingers are driven by tendons and actuated by human muscle-like actuators known as Pneumatic Artificial Muscle (PAM). The proposed design allows the actuators to be mounted outside the hand where each finger can be driven by one PAM actuator and six indirectly interlinked tendons. With this design, the three-fingered hand has a compact size and a lightweight with a mass of 150.25 grams imitating the human being hand in terms of size and weight. The hand also successfully grasped objects with different shapes and weights up to 500 g. Even though the number of PAM actuators equals the number of Degrees of Freedom (DOF), the design guarantees driving of three joints by only one actuator reducing the number of required actuators from 3 to 1. Therefore, this hand is suitable for researches of robotic applications in terms of design, cost and ability to be equipped with several types of sensors.

  7. Principal components analysis based control of a multi-dof underactuated prosthetic hand

    Directory of Open Access Journals (Sweden)

    Magenes Giovanni

    2010-04-01

    Full Text Available Abstract Background Functionality, controllability and cosmetics are the key issues to be addressed in order to accomplish a successful functional substitution of the human hand by means of a prosthesis. Not only the prosthesis should duplicate the human hand in shape, functionality, sensorization, perception and sense of body-belonging, but it should also be controlled as the natural one, in the most intuitive and undemanding way. At present, prosthetic hands are controlled by means of non-invasive interfaces based on electromyography (EMG. Driving a multi degrees of freedom (DoF hand for achieving hand dexterity implies to selectively modulate many different EMG signals in order to make each joint move independently, and this could require significant cognitive effort to the user. Methods A Principal Components Analysis (PCA based algorithm is used to drive a 16 DoFs underactuated prosthetic hand prototype (called CyberHand with a two dimensional control input, in order to perform the three prehensile forms mostly used in Activities of Daily Living (ADLs. Such Principal Components set has been derived directly from the artificial hand by collecting its sensory data while performing 50 different grasps, and subsequently used for control. Results Trials have shown that two independent input signals can be successfully used to control the posture of a real robotic hand and that correct grasps (in terms of involved fingers, stability and posture may be achieved. Conclusions This work demonstrates the effectiveness of a bio-inspired system successfully conjugating the advantages of an underactuated, anthropomorphic hand with a PCA-based control strategy, and opens up promising possibilities for the development of an intuitively controllable hand prosthesis.

  8. Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot

    Directory of Open Access Journals (Sweden)

    Godfrey Sasha B

    2010-07-01

    Full Text Available Abstract Background Following acute therapeutic interventions, the majority of stroke survivors are left with a poorly functioning hemiparetic hand. Rehabilitation robotics has shown promise in providing patients with intensive therapy leading to functional gains. Because of the hand's crucial role in performing activities of daily living, attention to hand therapy has recently increased. Methods This paper introduces a newly developed Hand Exoskeleton Rehabilitation Robot (HEXORR. This device has been designed to provide full range of motion (ROM for all of the hand's digits. The thumb actuator allows for variable thumb plane of motion to incorporate different degrees of extension/flexion and abduction/adduction. Compensation algorithms have been developed to improve the exoskeleton's backdrivability by counteracting gravity, stiction and kinetic friction. We have also designed a force assistance mode that provides extension assistance based on each individual's needs. A pilot study was conducted on 9 unimpaired and 5 chronic stroke subjects to investigate the device's ability to allow physiologically accurate hand movements throughout the full ROM. The study also tested the efficacy of the force assistance mode with the goal of increasing stroke subjects' active ROM while still requiring active extension torque on the part of the subject. Results For 12 of the hand digits'15 joints in neurologically normal subjects, there were no significant ROM differences (P > 0.05 between active movements performed inside and outside of HEXORR. Interjoint coordination was examined in the 1st and 3rd digits, and no differences were found between inside and outside of the device (P > 0.05. Stroke subjects were capable of performing free hand movements inside of the exoskeleton and the force assistance mode was successful in increasing active ROM by 43 ± 5% (P Conclusions Our pilot study shows that this device is capable of moving the hand's digits through

  9. Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot

    Science.gov (United States)

    2010-01-01

    Background Following acute therapeutic interventions, the majority of stroke survivors are left with a poorly functioning hemiparetic hand. Rehabilitation robotics has shown promise in providing patients with intensive therapy leading to functional gains. Because of the hand's crucial role in performing activities of daily living, attention to hand therapy has recently increased. Methods This paper introduces a newly developed Hand Exoskeleton Rehabilitation Robot (HEXORR). This device has been designed to provide full range of motion (ROM) for all of the hand's digits. The thumb actuator allows for variable thumb plane of motion to incorporate different degrees of extension/flexion and abduction/adduction. Compensation algorithms have been developed to improve the exoskeleton's backdrivability by counteracting gravity, stiction and kinetic friction. We have also designed a force assistance mode that provides extension assistance based on each individual's needs. A pilot study was conducted on 9 unimpaired and 5 chronic stroke subjects to investigate the device's ability to allow physiologically accurate hand movements throughout the full ROM. The study also tested the efficacy of the force assistance mode with the goal of increasing stroke subjects' active ROM while still requiring active extension torque on the part of the subject. Results For 12 of the hand digits'15 joints in neurologically normal subjects, there were no significant ROM differences (P > 0.05) between active movements performed inside and outside of HEXORR. Interjoint coordination was examined in the 1st and 3rd digits, and no differences were found between inside and outside of the device (P > 0.05). Stroke subjects were capable of performing free hand movements inside of the exoskeleton and the force assistance mode was successful in increasing active ROM by 43 ± 5% (P < 0.001) and 24 ± 6% (P = 0.041) for the fingers and thumb, respectively. Conclusions Our pilot study shows that this device

  10. From robot to human grasping simulation

    CERN Document Server

    León, Beatriz; Sancho-Bru, Joaquin

    2013-01-01

    The human hand and its dexterity in grasping and manipulating objects are some of the hallmarks of the human species. For years, anatomic and biomechanical studies have deepened the understanding of the human hand’s functioning and, in parallel, the robotics community has been working on the design of robotic hands capable of manipulating objects with a performance similar to that of the human hand. However, although many researchers have partially studied various aspects, to date there has been no comprehensive characterization of the human hand’s function for grasping and manipulation of

  11. Monoamine Oxidase Inhibitory Constituents of Propolis: Kinetics and Mechanism of Inhibition of Recombinant Human MAO-A and MAO-B

    Directory of Open Access Journals (Sweden)

    Narayan D. Chaurasiya

    2014-11-01

    Full Text Available Propolis is the resinous material that bees gather from leaf buds, flowers and vegetables. Propolis extracts contain constituents with a broad spectra of pharmacological properties and are important ingredients of popular dietary supplements. Propolis extracts were evaluated in vitro for inhibition of recombinant human monoamine oxidase (MAO-A and MAO-B. The dichloromethane extract of propolis showed potent inhibition of human MAO-A and MAO-B. Further fractionation identified the most active fractions as rich in flavonoids. Galangin and apigenin were identified as the principal MAO-inhibitory constituents. Inhibition of MAO-A by galangin was about 36 times more selective than MAO-B, while apigenin selectivity for MAO-A vs. MAO-B was about 1.7 fold. Apigenin inhibited MAO-B significantly more potently than galangin. Galangin and apigenin were further evaluated for kinetic characteristics and the mechanism for the enzymes’ inhibition. Binding of galangin and apigenin with MAO-A and -B was not time-dependent and was reversible, as suggested by enzyme-inhibitor binding and dissociation-dialysis assay. The inhibition kinetics studies suggested that galangin and apigenin inhibited MAO-A and -B by a competitive mechanism. Presence of prominent MAO inhibitory constituents in propolis products suggests their potential for eliciting pharmacological effects that might be useful in depression or other neurological disorders. The results may also have important implications in drug-dietary supplement interactions.

  12. Human disease mortality kinetics are explored through a chain model embodying principles of extreme value theory and competing risks.

    Science.gov (United States)

    Juckett, D A; Rosenberg, B

    1992-04-21

    The distributions for human disease-specific mortality exhibit two striking characteristics: survivorship curves that intersect near the longevity limit; and, the clustering of best-fitting Weibull shape parameter values into groups centered on integers. Correspondingly, we have hypothesized that the distribution intersections result from either competitive processes or population partitioning and the integral clustering in the shape parameter results from the occurrence of a small number of rare, rate-limiting events in disease progression. In this report we initiate a theoretical examination of these questions by exploring serial chain model dynamics and parameteric competing risks theory. The links in our chain models are composed of more than one bond, where the number of bonds in a link are denoted the link size and are the number of events necessary to break the link and, hence, the chain. We explored chains with all links of the same size or with segments of the chain composed of different size links (competition). Simulations showed that chain breakage dynamics depended on the weakest-link principle and followed kinetics of extreme-values which were very similar to human mortality kinetics. In particular, failure distributions for simple chains were Weibull-type extreme-value distributions with shape parameter values that were identifiable with the integral link size in the limit of infinite chain length. Furthermore, for chains composed of several segments of differing link size, the survival distributions for the various segments converged at a point in the S(t) tails indistinguishable from human data. This was also predicted by parameteric competing risks theory using Weibull underlying distributions. In both the competitive chain simulations and the parametric competing risks theory, however, the shape values for the intersecting distributions deviated from the integer values typical of human data. We conclude that rare events can be the source of

  13. Study of recognizing multiple persons' complicated hand gestures from the video sequence acquired by a moving camera

    Science.gov (United States)

    Dan, Luo; Ohya, Jun

    2010-02-01

    Recognizing hand gestures from the video sequence acquired by a dynamic camera could be a useful interface between humans and mobile robots. We develop a state based approach to extract and recognize hand gestures from moving camera images. We improved Human-Following Local Coordinate (HFLC) System, a very simple and stable method for extracting hand motion trajectories, which is obtained from the located human face, body part and hand blob changing factor. Condensation algorithm and PCA-based algorithm was performed to recognize extracted hand trajectories. In last research, this Condensation Algorithm based method only applied for one person's hand gestures. In this paper, we propose a principal component analysis (PCA) based approach to improve the recognition accuracy. For further improvement, temporal changes in the observed hand area changing factor are utilized as new image features to be stored in the database after being analyzed by PCA. Every hand gesture trajectory in the database is classified into either one hand gesture categories, two hand gesture categories, or temporal changes in hand blob changes. We demonstrate the effectiveness of the proposed method by conducting experiments on 45 kinds of sign language based Japanese and American Sign Language gestures obtained from 5 people. Our experimental recognition results show better performance is obtained by PCA based approach than the Condensation algorithm based method.

  14. Non-kinetic capabilities: complementing the kinetic prevalence to targeting

    OpenAIRE

    Ducheine, P.

    2014-01-01

    Targeting is used in military doctrine to describe a military operational way, using (military) means to influence a target (or addressee) in order to achieve designated political and/or military goals. The four factors italicized are used to analyse non-kinetic targeting, complementing our knowledge and understanding of the kinetic prevalence. Paradoxically, non-kinetic targeting is not recognized as a separate concept: kinetic and non-kinetic are intertwined facets of targeting. Kinetic tar...

  15. Kinetics of EGFR expression during fractionated irradiation varies between different human squamous cell carcinoma lines in nude mice

    International Nuclear Information System (INIS)

    Eicheler, Wolfgang; Krause, Mechthild; Hessel, Franziska; Zips, Daniel; Baumann, Michael

    2005-01-01

    Background and purpose: Preclinical and clinical data indicate that high pretherapeutic EGFR expression is associated with poor local tumour control, possibly caused by a high repopulation rate of clonogenic cells during radiotherapy in these tumours. Previous data reported from our laboratory showed a correlation between EGFR expression and acceleration of repopulation in poorly differentiated FaDu human squamous cell carcinoma (SCC) during fractionated irradiation. To test whether this is a general phenomenon, two further SCC were investigated in the present study. Patients and methods: GL and UT-SCC-14, two moderately well differentiated and keratinising hSCC, were grown as xenografts in nude mice. Functional data on the repopulation kinetics during fractionated irradiation for these tumour models have been previously determined. The expression of EGFR during fractionation was analysed by immunohistochemistry. Endpoints were the membrane-staining score and the proportion of EGFR-positive cells (EGFR labelling index). Results: Different kinetics of EGFR expression during fractionated RT were found. In UT-SCC-14, EGFR staining score and labelling index increased significantly during radiotherapy. In GL SCC, the EGFR expression was unchanged. Both tumours are characterized by a small but significant repopulation rate during radiotherapy. Conclusions: The expression of EGFR may change significantly during fractionated irradiation. No clear correlation between EGFR expression and the repopulation kinetics of clonogenic tumour cells during fractionated irradiation was found. The changes in EGFR expression during irradiation warrant further investigation on their prognostic implications and on their importance for therapeutic interventions

  16. Hand Matters: Left-Hand Gestures Enhance Metaphor Explanation

    Science.gov (United States)

    Argyriou, Paraskevi; Mohr, Christine; Kita, Sotaro

    2017-01-01

    Research suggests that speech-accompanying gestures influence cognitive processes, but it is not clear whether the gestural benefit is specific to the gesturing hand. Two experiments tested the "(right/left) hand-specificity" hypothesis for self-oriented functions of gestures: gestures with a particular hand enhance cognitive processes…

  17. Sub-minute kinetics of human red cell fumarase: 1 H spin-echo NMR spectroscopy and 13 C rapid-dissolution dynamic nuclear polarization.

    Science.gov (United States)

    Shishmarev, Dmitry; Wright, Alan J; Rodrigues, Tiago B; Pileio, Giuseppe; Stevanato, Gabriele; Brindle, Kevin M; Kuchel, Philip W

    2018-03-01

    Fumarate is an important probe of metabolism in hyperpolarized magnetic resonance imaging and spectroscopy. It is used to detect the release of fumarase in cancer tissues, which is associated with necrosis and drug treatment. Nevertheless, there are limited reports describing the detailed kinetic studies of this enzyme in various cells and tissues. Thus, we aimed to evaluate the sub-minute kinetics of human red blood cell fumarase using nuclear magnetic resonance (NMR) spectroscopy, and to provide a quantitative description of the enzyme that is relevant to the use of fumarate as a probe of cell rupture. The fumarase reaction was studied using time courses of 1 H spin-echo and 13 C-NMR spectra. 1 H-NMR experiments showed that the fumarase reaction in hemolysates is sufficiently rapid to make its kinetics amenable to study in a period of approximately 3 min, a timescale characteristic of hyperpolarized 13 C-NMR spectroscopy. The rapid-dissolution dynamic nuclear polarization (RD-DNP) technique was used to hyperpolarize [1,4- 13 C]fumarate, which was injected into concentrated hemolysates. The kinetic data were analyzed using recently developed FmR α analysis and modeling of the enzymatic reaction using Michaelis-Menten equations. In RD-DNP experiments, the decline in the 13 C-NMR signal from fumarate, and the concurrent rise and fall of that from malate, were captured with high spectral resolution and signal-to-noise ratio, which allowed the robust quantification of fumarase kinetics. The kinetic parameters obtained indicate the potential contribution of hemolysis to the overall rate of the fumarase reaction when 13 C-NMR RD-DNP is used to detect necrosis in animal models of implanted tumors. The analytical procedures developed will be applicable to studies of other rapid enzymatic reactions using conventional and hyperpolarized substrate NMR spectroscopy. Copyright © 2018 John Wiley & Sons, Ltd.

  18. A Biomechanical Model for the Development of Myoelectric Hand Prosthesis Control Systems

    NARCIS (Netherlands)

    Peerdeman, B.; van Baal, D.W.; Boere, Daphne; Kallenberg, L.A.C.; Stramigioli, Stefano; Misra, Sarthak

    2010-01-01

    Advanced myoelectric hand prostheses aim to reproduce as much of the human hand's functionality as possible. Development of the control system of such a prosthesis is strongly connected to its mechanical design; the control system requires accurate information on the prosthesis' structure and the

  19. [Hand osteoarthritis].

    Science.gov (United States)

    Šenolt, Ladislav

    Hand osteoarthritis (OA) is a common chronic disorder causing pain and limitation of mobility of affected joints. The prevalence of hand OA increases with age and more often affects females. Clinical signs obviously do not correlate with radiographic findings - symptomatic hand OA affects approximately 26 % of adult subjects, but radiographic changes can be found in up to two thirds of females and half of males older than 55 years.Disease course differ among individual patients. Hand OA is a heterogeneous disease. Nodal hand OA is the most common subtype affecting interphalangeal joints, thumb base OA affects first carpometacarpal joint. Erosive OA represents a specific subtype of hand OA, which is associated with joint inflammation, more pain, functional limitation and erosive findings on radiographs.Treatment of OA is limited. Analgesics and nonsteroidal anti-inflammatory drugs are the only agents reducing symptoms. New insights into the pathogenesis of disease should contribute to the development of novel effective treatment of hand OA.

  20. Specialization of the left supramarginal gyrus for hand-independent praxis representation is not related to hand dominance

    Science.gov (United States)

    Króliczak, Gregory; Piper, Brian J.; Frey, Scott H.

    2016-01-01

    Data from focal brain injury and functional neuroimaging studies implicate a distributed network of parieto-fronto-temporal areas in the human left cerebral hemisphere as playing distinct roles in the representation of meaningful actions (praxis). Because these data come primarily from right-handed individuals, the relationship between left cerebral specialization for praxis representation and hand dominance remains unclear. We used functional magnetic resonance imaging (fMRI) to evaluate the hypothesis that strongly left-handed (right hemisphere motor dominant) adults also exhibit this left cerebral specialization. Participants planned familiar actions for subsequent performance with the left or right hand in response to transitive (e.g., “pounding”) or intransitive (e.g. “waving”) action words. In linguistic control trials, cues denoted non-physical actions (e.g., “believing”). Action planning was associated with significant, exclusively left-lateralized and extensive increases of activity in the supramarginal gyrus (SMg), and more focal modulations in the left caudal middle temporal gyrus (cMTg). This activity was hand- and gesture-independent, i.e., unaffected by the hand involved in subsequent action performance, and the type of gesture (i.e., transitive or intransitive). Compared directly with right-handers, left-handers exhibited greater involvement of the right angular gyrus (ANg) and dorsal premotor cortex (dPMC), which is indicative of a less asymmetric functional architecture for praxis representation. We therefore conclude that the organization of mechanisms involved in planning familiar actions is influenced by one’s motor dominance. However, independent of hand dominance, the left SMg and cMTg are specialized for ideomotor transformations—the integration of conceptual knowledge and motor representations into meaningful actions. These findings support the view that higher-order praxis representation and lower-level motor dominance rely

  1. An Approach for Pattern Recognition of EEG Applied in Prosthetic Hand Drive

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Zhang

    2011-12-01

    Full Text Available For controlling the prosthetic hand by only electroencephalogram (EEG, it has become the hot spot in robotics research to set up a direct communication and control channel between human brain and prosthetic hand. In this paper, the EEG signal is analyzed based on multi-complicated hand activities. And then, two methods of EEG pattern recognition are investigated, a neural prosthesis hand system driven by BCI is set up, which can complete four kinds of actions (arm’s free state, arm movement, hand crawl, hand open. Through several times of off-line and on-line experiments, the result shows that the neural prosthesis hand system driven by BCI is reasonable and feasible, the C-support vector classifiers-based method is better than BP neural network on the EEG pattern recognition for multi-complicated hand activities.

  2. Integration of robotics and neuroscience beyond the hand: What kind of synergies?. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by Marco Santello et al.

    Science.gov (United States)

    d'Avella, Andrea

    2016-07-01

    Santello et al. [1] review an impressive amount of work on the control of biological and artificial hands that demonstrates how the concept of synergies can lead to a successful integration of robotics and neuroscience. Is it possible to generalize the same approach to the control of biological and artificial limbs and bodies beyond the hand? The human hand synergies that appear most relevant for robotic hands are those defined at the kinematic level, i.e. postural synergies [2]. Postural synergies capture the geometric relations among the many joints of the hand and allow for a low dimensional characterization and synthesis of the static hand postures involved in grasping and manipulating a large set of objects. However, many other complex motor skills such as walking, reaching, throwing, and catching require controlling multi-articular time-varying trajectories rather than static postures. Dynamic control of biological and artificial limbs and bodies, especially when geometric and inertial parameters are uncertain and the joints are compliant, poses great challenges. What kind of synergies might simplify the dynamic control of motor skills involving upper and lower limbs as well as the whole body?

  3. Development of a PBPK model of thiocyanate in rats with an extrapolation to humans: A computational study to quantify the mechanism of action of thiocyanate kinetics in thyroid

    International Nuclear Information System (INIS)

    Willemin, Marie-Emilie; Lumen, Annie

    2016-01-01

    Thyroid homeostasis can be disturbed due to thiocyanate exposure from the diet or tobacco smoke. Thiocyanate inhibits both thyroidal uptake of iodide, via the sodium-iodide symporter (NIS), and thyroid hormone (TH) synthesis in the thyroid, via thyroid peroxidase (TPO), but the mode of action of thiocyanate is poorly quantified in the literature. The characterization of the link between intra-thyroidal thiocyanate concentrations and dose of exposure is crucial for assessing the risk of thyroid perturbations due to thiocyanate exposure. We developed a PBPK model for thiocyanate that describes its kinetics in the whole-body up to daily doses of 0.15 mmol/kg, with a mechanistic description of the thyroidal kinetics including NIS, passive diffusion, and TPO. The model was calibrated in a Bayesian framework using published studies in rats. Goodness-of-fit was satisfactory, especially for intra-thyroidal thiocyanate concentrations. Thiocyanate kinetic processes were quantified in vivo, including the metabolic clearance by TPO. The passive diffusion rate was found to be greater than NIS-mediated uptake rate. The model captured the dose-dependent kinetics of thiocyanate after acute and chronic exposures. Model behavior was evaluated using a Morris screening test. The distribution of thiocyanate into the thyroid was found to be determined primarily by the partition coefficient, followed by NIS and passive diffusion; the impact of the latter two mechanisms appears to increase at very low doses. Extrapolation to humans resulted in good predictions of thiocyanate kinetics during chronic exposure. The developed PBPK model can be used in risk assessment to quantify dose-response effects of thiocyanate on TH. - Highlights: • A PBPK model of thiocyanate (SCN − ) was calibrated in rats in a Bayesian framework. • The intra-thyroidal kinetics of thiocyanate including NIS and TPO was modeled. • Passive diffusion rate for SCN − seemed to be greater than the NIS

  4. Development of a PBPK model of thiocyanate in rats with an extrapolation to humans: A computational study to quantify the mechanism of action of thiocyanate kinetics in thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Willemin, Marie-Emilie; Lumen, Annie, E-mail: Annie.Lumen@fda.hhs.gov

    2016-09-15

    Thyroid homeostasis can be disturbed due to thiocyanate exposure from the diet or tobacco smoke. Thiocyanate inhibits both thyroidal uptake of iodide, via the sodium-iodide symporter (NIS), and thyroid hormone (TH) synthesis in the thyroid, via thyroid peroxidase (TPO), but the mode of action of thiocyanate is poorly quantified in the literature. The characterization of the link between intra-thyroidal thiocyanate concentrations and dose of exposure is crucial for assessing the risk of thyroid perturbations due to thiocyanate exposure. We developed a PBPK model for thiocyanate that describes its kinetics in the whole-body up to daily doses of 0.15 mmol/kg, with a mechanistic description of the thyroidal kinetics including NIS, passive diffusion, and TPO. The model was calibrated in a Bayesian framework using published studies in rats. Goodness-of-fit was satisfactory, especially for intra-thyroidal thiocyanate concentrations. Thiocyanate kinetic processes were quantified in vivo, including the metabolic clearance by TPO. The passive diffusion rate was found to be greater than NIS-mediated uptake rate. The model captured the dose-dependent kinetics of thiocyanate after acute and chronic exposures. Model behavior was evaluated using a Morris screening test. The distribution of thiocyanate into the thyroid was found to be determined primarily by the partition coefficient, followed by NIS and passive diffusion; the impact of the latter two mechanisms appears to increase at very low doses. Extrapolation to humans resulted in good predictions of thiocyanate kinetics during chronic exposure. The developed PBPK model can be used in risk assessment to quantify dose-response effects of thiocyanate on TH. - Highlights: • A PBPK model of thiocyanate (SCN{sup −}) was calibrated in rats in a Bayesian framework. • The intra-thyroidal kinetics of thiocyanate including NIS and TPO was modeled. • Passive diffusion rate for SCN{sup −} seemed to be greater than the NIS

  5. NOTE: A preliminary study for non-invasive quantification of manganese in human hand bones

    Science.gov (United States)

    Aslam; Pejović-Milić, A.; Chettle, D. R.; McNeill, F. E.; Pysklywec, M. W.; Oudyk, J.

    2008-10-01

    Manganese (Mn) is a nutrient essential for regulating neurological and skeletal functions in the human body, but it is also toxic when humans are excessively exposed to Mn. Blood (or serum/plasma) and other body fluids reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive measurement of Mn stored in bone, using in vivo neutron activation analysis. Following feasibility studies, a first pilot study, using neutron activation analysis to measure Mn in the bones of the hand of ten healthy male human subjects, was conducted with the approval of the concerned research ethics boards. The participants of this study had no known history of exposure to Mn. Two volunteers were excluded from this study due to technical problems with their measurements. The inverse variance weighted mean value of Mn/Ca for the participants of this study is 0.12 ± 0.68 µg Mn/g Ca which is comparable within uncertainties with the estimated range of 0.16 0.78 µg Mn/g Ca and mean value of 0.63 ± 0.30 µg Mn/g Ca derived from cadaver data. It is recommended to investigate the use of the diagnostic technique for in vivo measurements of workers exposed occupationally to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. The technique needs further development to improve the precision of in vivo measurements in the non-exposed population.

  6. Denmark: HAND in HAND Policy Questionnaire

    DEFF Research Database (Denmark)

    Laursen, Hilmar Dyrborg; Nielsen, Birgitte Lund

    2018-01-01

    Som del af det internationale EU finansierede projekt Hand in Hand, der fokuserer på de såkaldte SEI-kompetencer (Social, Emotional, Intercultural), er dansk policy i relation til elevernes sociale, emotionelle og interkulturelle læring kortlagt i denne rapport. Der refereres bl.a. til "elevernes...

  7. A motion-planning method for dexterous hand operating a tool based on bionic analysis

    Directory of Open Access Journals (Sweden)

    Wei Bo

    2017-01-01

    Full Text Available In order to meet the needs of robot’s operating tools for different types and sizes, the dexterous hand is studied by many scientific research institutions. However, the large number of joints in a dexterous hand leads to the difficulty of motion planning. Aiming at this problem, this paper proposes a planning method abased on BPNN inspired by human hands. Firstly, this paper analyses the structure and function of the human hand and summarizes its typical strategy of operation. Secondly, based on the manual operation strategy, the tools are classified according to the shape and the operation mode of the dexterous hand is presented. Thirdly, the BPNN is used to train the humanoid operation, and then output the operation plan. Finally, the simulating experiments of grasping simple tools and operating complex tools are made by MATLAB and ADAMS. The simulation verifies the effectiveness of this method.

  8. Study of human body: Kinematics and kinetics of a martial arts (Silat) performers using 3D-motion capture

    Science.gov (United States)

    Soh, Ahmad Afiq Sabqi Awang; Jafri, Mohd Zubir Mat; Azraai, Nur Zaidi

    2015-04-01

    The Interest in this studies of human kinematics goes back very far in human history drove by curiosity or need for the understanding the complexity of human body motion. To find new and accurate information about the human movement as the advance computing technology became available for human movement that can perform. Martial arts (silat) were chose and multiple type of movement was studied. This project has done by using cutting-edge technology which is 3D motion capture to characterize and to measure the motion done by the performers of martial arts (silat). The camera will detect the markers (infrared reflection by the marker) around the performer body (total of 24 markers) and will show as dot in the computer software. The markers detected were analyzing using kinematic kinetic approach and time as reference. A graph of velocity, acceleration and position at time,t (seconds) of each marker was plot. Then from the information obtain, more parameters were determined such as work done, momentum, center of mass of a body using mathematical approach. This data can be used for development of the effectiveness movement in martial arts which is contributed to the people in arts. More future works can be implemented from this project such as analysis of a martial arts competition.

  9. The Kinetics of Swinging a Baseball Bat.

    Science.gov (United States)

    Crisco, Joseph J; Osvalds, Nikolas J; Rainbow, Michael J

    2018-04-13

    The purpose of this study was to compute the three-dimensional kinetics required to swing three youth baseball bats of varying moments of inertia (MOI). 306 swings by 22 male players (13-18 yrs.) were analyzed. Inverse dynamics with respect to the batter's hands were computed given the known kinematics and physical properties of the bats. We found that peak force increased with larger bat MOI and was strongly correlated with bat tip speed. In contrast, peak moments were weakly correlated with bat MOI and bat tip speed. Throughout the swing, the force applied to the bat was dominated by a component aligned with the long axis of the bat and directed away from the bat knob, while the moment applied to the bat was minimal until just prior to ball impact. These results indicate that players act to mostly "pull" the bat during their swing until just prior to ball impact, at which point they rapidly increase the moment on the bat. This kinetic analysis provides novel insight into the forces and moments used to swing baseball bats.

  10. Monitoring the initiation and kinetics of human dendritic cell-induced polarization of autologous naive CD4+ T cells.

    Directory of Open Access Journals (Sweden)

    Tammy Oth

    Full Text Available A crucial step in generating de novo immune responses is the polarization of naive cognate CD4+ T cells by pathogen-triggered dendritic cells (DC. In the human setting, standardized DC-dependent systems are lacking to study molecular events during the initiation of a naive CD4+ T cell response. We developed a TCR-restricted assay to compare different pathogen-triggered human DC for their capacities to instruct functional differentiation of autologous, naive CD4+ T cells. We demonstrated that this methodology can be applied to compare differently matured DC in terms of kinetics, direction, and magnitude of the naive CD4+ T cell response. Furthermore, we showed the applicability of this assay to study the T cell polarizing capacity of low-frequency blood-derived DC populations directly isolated ex vivo. This methodology for addressing APC-dependent instruction of naive CD4+ T cells in a human autologous setting will provide researchers with a valuable tool to gain more insight into molecular mechanisms occurring in the early phase of T cell polarization. In addition, it may also allow the study of pharmacological agents on DC-dependent T cell polarization in the human system.

  11. The human touch: skin temperature during the rubber hand illusion in manual and automated stroking procedures.

    Directory of Open Access Journals (Sweden)

    Marieke Rohde

    Full Text Available A difference in skin temperature between the hands has been identified as a physiological correlate of the rubber hand illusion (RHI. The RHI is an illusion of body ownership, where participants perceive body ownership over a rubber hand if they see it being stroked in synchrony with their own occluded hand. The current study set out to replicate this result, i.e., psychologically induced cooling of the stimulated hand using an automated stroking paradigm, where stimulation was delivered by a robot arm (PHANToM(TM force-feedback device. After we found no evidence for hand cooling in two experiments using this automated procedure, we reverted to a manual stroking paradigm, which is closer to the one employed in the study that first produced this effect. With this procedure, we observed a relative cooling of the stimulated hand in both the experimental and the control condition. The subjective experience of ownership, as rated by the participants, by contrast, was strictly linked to synchronous stroking in all three experiments. This implies that hand-cooling is not a strict correlate of the subjective feeling of hand ownership in the RHI. Factors associated with the differences between the two designs (differences in pressure of tactile stimulation, presence of another person that were thus far considered irrelevant to the RHI appear to play a role in bringing about this temperature effect.

  12. Kinetics, bioavailability, and metabolism of RRR-alpha-tocopherol in humans supports lower requirement for vitamin E

    Science.gov (United States)

    Kinetic models enable nutrient needs and kinetic behaviors to be quantified and provide mechanistic insights into metabolism. Therefore, we modeled and quantified the kinetics, bioavailability and metabolism of RRR-alpha-tocopherol in 12 healthy adults. Six men and six women, aged 27 ± 6 y, each i...

  13. Hand Surgery: Anesthesia

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Hand Surgery Anesthesia Email to a friend * required ...

  14. The hot hand belief and framing effects.

    Science.gov (United States)

    MacMahon, Clare; Köppen, Jörn; Raab, Markus

    2014-09-01

    Recent evidence of the hot hand in sport-where success breeds success in a positive recency of successful shots, for instance-indicates that this pattern does not actually exist. Yet the belief persists. We used 2 studies to explore the effects of framing on the hot hand belief in sport. We looked at the effect of sport experience and task on the perception of baseball pitch behavior as well as the hot hand belief and free-throw behavior in basketball. Study 1 asked participants to designate outcomes with different alternation rates as the result of baseball pitches or coin tosses. Study 2 examined basketball free-throw behavior and measured predicted success before each shot as well as general belief in the hot hand pattern. The results of Study 1 illustrate that experience and stimulus alternation rates influence the perception of chance in human performance tasks. Study 2 shows that physically performing an act and making judgments are related. Specifically, beliefs were related to overall performance, with more successful shooters showing greater belief in the hot hand and greater predicted success for upcoming shots. Both of these studies highlight that the hot hand belief is influenced by framing, which leads to instability and situational contingencies. We show the specific effects of framing using accumulated experience of the individual with the sport and knowledge of its structure and specific experience with sport actions (basketball shots) prior to judgments.

  15. Smart Prosthetic Hand Technology - Phase 2

    Science.gov (United States)

    2011-05-01

    functional magnetic resonance imaging (f- MRI ) was used to analyze the reciprocal adaptation between the human brain and the prosthetic hand by the...Schmidt PC. Influence of compacted hydrophobic and hydrophilic colloidal silicon dioxide on tableting properties of pharmaceutical excipients. Drug Dev...nanoparticles, and manganese nanoparticles) in magnetic resonance imaging ( MRI ) in the detection and staging of cancer [2]. 2.1 Iron Oxide

  16. Hand Anatomy

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy Bones Joints Muscles Nerves Vessels Tendons Anatomy The upper extremity is ...

  17. Warm hands, cold heart: progressive whole-body cooling increases warm thermosensitivity of human hands and feet in a dose-dependent fashion.

    Science.gov (United States)

    Filingeri, Davide; Morris, Nathan B; Jay, Ollie

    2017-01-01

    What is the central question of this study? Investigations on inhibitory/facilitatory modulation of vision, touch and pain show that conditioning stimuli outside the receptive field of testing stimuli modulate the central processing of visual, touch and painful stimuli. We asked whether contextual modulation also exists in human temperature integration. What is the main finding and its importance? Progressive decreases in whole-body mean skin temperature (the conditioning stimulus) significantly increased local thermosensitivity to skin warming but not cooling (the testing stimuli) in a dose-dependent fashion. In resembling the central mechanisms underlying endogenous analgesia, our findings point to the existence of an endogenous thermosensory system in humans that could modulate local skin thermal sensitivity to facilitate thermal behaviour. Although inhibitory/facilitatory central modulation of vision and pain has been investigated, contextual modulation of skin temperature integration has not been explored. Hence, we tested whether progressive decreases in whole-body mean skin temperature (T sk ; a large conditioning stimulus) alter the magnitude estimation of local warming and cooling stimuli applied to hairy and glabrous skin. On four separate occasions, eight men (27 ± 5 years old) underwent a 30 min whole-body cooling protocol (water-perfused suit; temperature, 5°C), during which a quantitative thermosensory test, consisting of reporting the perceived magnitude of warming and cooling stimuli (±8°C from 30°C baseline) applied to the hand (palm/dorsum) and foot (sole/dorsum), was performed before cooling and every 10 min thereafter. The cooling protocol resulted in large progressive reductions in T sk [10 min, -3.36°C (95% confidence interval -2.62 to -4.10); 20 min, -5.21°C (-4.47 to -5.95); and 30 min, -6.32°C (-5.58 to -7.05); P fashion. In highlighting a novel feature of human temperature integration, these findings point to the existence

  18. Web-based interactive drone control using hand gesture

    Science.gov (United States)

    Zhao, Zhenfei; Luo, Hao; Song, Guang-Hua; Chen, Zhou; Lu, Zhe-Ming; Wu, Xiaofeng

    2018-01-01

    This paper develops a drone control prototype based on web technology with the aid of hand gesture. The uplink control command and downlink data (e.g., video) are transmitted by WiFi communication, and all the information exchange is realized on web. The control command is translated from various predetermined hand gestures. Specifically, the hardware of this friendly interactive control system is composed by a quadrotor drone, a computer vision-based hand gesture sensor, and a cost-effective computer. The software is simplified as a web-based user interface program. Aided by natural hand gestures, this system significantly reduces the complexity of traditional human-computer interaction, making remote drone operation more intuitive. Meanwhile, a web-based automatic control mode is provided in addition to the hand gesture control mode. For both operation modes, no extra application program is needed to be installed on the computer. Experimental results demonstrate the effectiveness and efficiency of the proposed system, including control accuracy, operation latency, etc. This system can be used in many applications such as controlling a drone in global positioning system denied environment or by handlers without professional drone control knowledge since it is easy to get started.

  19. Web-based interactive drone control using hand gesture.

    Science.gov (United States)

    Zhao, Zhenfei; Luo, Hao; Song, Guang-Hua; Chen, Zhou; Lu, Zhe-Ming; Wu, Xiaofeng

    2018-01-01

    This paper develops a drone control prototype based on web technology with the aid of hand gesture. The uplink control command and downlink data (e.g., video) are transmitted by WiFi communication, and all the information exchange is realized on web. The control command is translated from various predetermined hand gestures. Specifically, the hardware of this friendly interactive control system is composed by a quadrotor drone, a computer vision-based hand gesture sensor, and a cost-effective computer. The software is simplified as a web-based user interface program. Aided by natural hand gestures, this system significantly reduces the complexity of traditional human-computer interaction, making remote drone operation more intuitive. Meanwhile, a web-based automatic control mode is provided in addition to the hand gesture control mode. For both operation modes, no extra application program is needed to be installed on the computer. Experimental results demonstrate the effectiveness and efficiency of the proposed system, including control accuracy, operation latency, etc. This system can be used in many applications such as controlling a drone in global positioning system denied environment or by handlers without professional drone control knowledge since it is easy to get started.

  20. Reactivation of organophosphate-inhibited human acetylcholinesterase by isonitrosoacetone (MINA): a kinetic analysis.

    Science.gov (United States)

    Worek, Franz; Thiermann, Horst

    2011-11-15

    Treatment of poisoning by highly toxic organophosphorus compounds (OP) with atropine and an acetylcholinesterase (AChE) reactivator (oxime) is of limited effectiveness in case of different nerve agents and pesticides. One challenge is the reactivation of OP-inhibited brain AChE which shows inadequate success with charged pyridinium oximes. Recent studies with high doses of the tertiary oxime isonitrosoacetone (MINA) indicated a beneficial effect on central and peripheral AChE and on survival in nerve agent poisoned guinea pigs. Now, an in vitro study was performed to determine the reactivation kinetics of MINA with tabun-, sarin-, cyclosarin-, VX- and paraoxon-inhibited human AChE. MINA showed an exceptionally low affinity to inhibited AChE but, with the exception of tabun-inhibited AChE, a moderate to high reactivity. In comparison to the pyridinium oximes obidoxime, 2-PAM and HI-6 the affinity and reactivity of MINA was in most cases lower and in relation to the most effective reactivators, the second order reactivation constant of MINA was 500 to 3400-fold lower. Hence, high in vivo MINA concentrations would be necessary to achieve at least partial reactivation. This assumption corresponds to in vivo data showing a dose-dependent effect on reactivation and survival in animals. In view, of the toxic potential of MINA in animals human studies would be necessary to determine the tolerability and pharmacokinetics of MINA in order to enable a proper assessment of the value of this oxime as an antidote in OP poisoning. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. Culture of normal human blood cells in a diffusion chamber system II. Lymphocyte and plasma cell kinetics

    International Nuclear Information System (INIS)

    Chikkappa, G.; Carsten, A.L.; Chanana, A.D.; Cronkite, E.P.

    1979-01-01

    Normal human blood leukocytes were cultured in Millipore diffusion chambers implanted into the peritoneal cavities of irradiated mice. The evaluation of survival and proliferation kinetics of cells in lymphyocytic series suggested that the lymphoid cells are formed from transition of small and/or large lymphocytes, and the lymphoblasts from the lymphoid cells. There was also evidence indicating that some of the cells in these two compartments are formed by proliferation. The evaluation of plasmacytic series suggested that the plasma cells are formed from plasmacytoid-lymphocytes by transition, and the latter from the transition of lymphocytes. In addition, relatively a small fraction of cells in these two compartments are formed by proliferation. mature plasma cells do not and immature plasma cells do proliferate. Estimation of magnitude of plasma cells formed in the cultures at day 18 indicated that at least one plasma cell is formed for every 6 normal human blood lymphocytes introduced into the culture

  2. Iterative Addition of Kinetic Effects to Cold Plasma RF Wave Solvers

    Science.gov (United States)

    Green, David; Berry, Lee; RF-SciDAC Collaboration

    2017-10-01

    The hot nature of fusion plasmas requires a wave vector dependent conductivity tensor for accurate calculation of wave heating and current drive. Traditional methods for calculating the linear, kinetic full-wave plasma response rely on a spectral method such that the wave vector dependent conductivity fits naturally within the numerical method. These methods have seen much success for application to the well-confined core plasma of tokamaks. However, quantitative prediction of high power RF antenna designs for fusion applications has meant a requirement of resolving the geometric details of the antenna and other plasma facing surfaces for which the Fourier spectral method is ill-suited. An approach to enabling the addition of kinetic effects to the more versatile finite-difference and finite-element cold-plasma full-wave solvers was presented by where an operator-split iterative method was outlined. Here we expand on this approach, examine convergence and present a simplified kinetic current estimator for rapidly updating the right-hand side of the wave equation with kinetic corrections. This research used resources of the Oak Ridge Leadership Computing Facility at the Oak Ridge National Laboratory, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725.

  3. Theoretical and experimental assessment of the kinetic properties of N-isopropyl-p-[{sup 123}I]iodoamphetamine in the human brain

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kentaro; Nakajima, Keiji; Maeda, Minoru [Juntendo Univ., Shizuoka (Japan). Izunagaoka Hospital

    1993-12-01

    The effect of the loss of radioactivity from the human brain on the measurement of regional cerebral blood flow (rCBF) using N-isopropyl-p-[{sup 123}I]iodoamphetamine (IMP) was evaluated by measuring rCBF in 10 normal male volunteers from 0.5 to 30 minutes after intravenous administration. rCBF was calculated by the operational equation, which assumes no product loss. Brain tissue and arterial blood concentration data were plotted according to a multiple-time/graphic evaluation technique. Data were fitted to the kinetic three-compartment model to estimate four kinetic rate constants to evaluate activity loss from the brain. These studies showed that loss of activity from the brain is negligible during the first 5 minutes, but after 7.5 minutes the loss becomes significantly higher with time. The present study corroborates the necessity for using single photon emission computed tomographic images measured within 5 minutes of IMP injection to quantify rCBF. (author).

  4. Hand posture classification using electrocorticography signals in the gamma band over human sensorimotor brain areas

    Science.gov (United States)

    Chestek, Cynthia A.; Gilja, Vikash; Blabe, Christine H.; Foster, Brett L.; Shenoy, Krishna V.; Parvizi, Josef; Henderson, Jaimie M.

    2013-04-01

    Objective. Brain-machine interface systems translate recorded neural signals into command signals for assistive technology. In individuals with upper limb amputation or cervical spinal cord injury, the restoration of a useful hand grasp could significantly improve daily function. We sought to determine if electrocorticographic (ECoG) signals contain sufficient information to select among multiple hand postures for a prosthetic hand, orthotic, or functional electrical stimulation system.Approach. We recorded ECoG signals from subdural macro- and microelectrodes implanted in motor areas of three participants who were undergoing inpatient monitoring for diagnosis and treatment of intractable epilepsy. Participants performed five distinct isometric hand postures, as well as four distinct finger movements. Several control experiments were attempted in order to remove sensory information from the classification results. Online experiments were performed with two participants. Main results. Classification rates were 68%, 84% and 81% for correct identification of 5 isometric hand postures offline. Using 3 potential controls for removing sensory signals, error rates were approximately doubled on average (2.1×). A similar increase in errors (2.6×) was noted when the participant was asked to make simultaneous wrist movements along with the hand postures. In online experiments, fist versus rest was successfully classified on 97% of trials; the classification output drove a prosthetic hand. Online classification performance for a larger number of hand postures remained above chance, but substantially below offline performance. In addition, the long integration windows used would preclude the use of decoded signals for control of a BCI system. Significance. These results suggest that ECoG is a plausible source of command signals for prosthetic grasp selection. Overall, avenues remain for improvement through better electrode designs and placement, better participant training

  5. Hand hygiene regimens for the reduction of risk in food service environments.

    Science.gov (United States)

    Edmonds, Sarah L; McCormack, Robert R; Zhou, Sifang Steve; Macinga, David R; Fricker, Christopher M

    2012-07-01

    Pathogenic strains of Escherichia coli and human norovirus are the main etiologic agents of foodborne illness resulting from inadequate hand hygiene practices by food service workers. This study was conducted to evaluate the antibacterial and antiviral efficacy of various hand hygiene product regimens under different soil conditions representative of those in food service settings and assess the impact of product formulation on this efficacy. On hands contaminated with chicken broth containing E. coli, representing a moderate soil load, a regimen combining an antimicrobial hand washing product with a 70% ethanol advanced formula (EtOH AF) gel achieved a 5.22-log reduction, whereas a nonantimicrobial hand washing product alone achieved a 3.10log reduction. When hands were heavily soiled from handling ground beef containing E. coli, a wash-sanitize regimen with a 0.5% chloroxylenol antimicrobial hand washing product and the 70% EtOH AF gel achieved a 4.60-log reduction, whereas a wash-sanitize regimen with a 62% EtOH foam achieved a 4.11-log reduction. Sanitizing with the 70% EtOH AF gel alone was more effective than hand washing with a nonantimicrobial product for reducing murine norovirus (MNV), a surrogate for human norovirus, with 2.60- and 1.79-log reductions, respectively. When combined with hand washing, the 70% EtOH AF gel produced a 3.19-log reduction against MNV. A regimen using the SaniTwice protocol with the 70% EtOH AF gel produced a 4.04-log reduction against MNV. These data suggest that although the process of hand washing helped to remove pathogens from the hands, use of a wash-sanitize regimen was even more effective for reducing organisms. Use of a high-efficacy sanitizer as part of a wash-sanitize regimen further increased the efficacy of the regimen. The use of a well-formulated alcohol-based hand rub as part of a wash-sanitize regimen should be considered as a means to reduce risk of infection transmission in food service facilities.

  6. Kinetic model building using advanced nuclear medicine techniques: the kinetics of chromium(III) in the human body

    International Nuclear Information System (INIS)

    Lim, T.H.

    1978-06-01

    The purpose of this study is to investigate whether a valid index of chromium (III) nutritional status can be determined with satisfaction through in vivo kinetic analysis. Three normal subjects and three patients suffering from hemochromatosis were periodically scanned with the Donner Laboratory computerized whole body scanners, starting seconds after radiochromium(III) was administered intravenously, up to a period of 84 days. The activity in the liver, adipose and muscle tissues, spleen and bone was quantitated and corrected, by subtraction of the blood circulation activity in that organ; the major concentration was found in the liver and spleen. From the series of scan images, a kinetic model for the radiochromium(III) metabolic pathway was constructed. Computer analysis showed a significant difference between the two classes of subjects in organs as well as whole body radiochromium(III) transfer. Interpretation of these results showed that in patients with excessive iron stores, a smaller amount of chromium bound to plasma protein was found and a corresponding decrease in transfer of chromium into stores in the liver and other tissues was also found

  7. Laterality and grip strength influence hand bone micro-architecture in modern humans, an HRpQCT study.

    Science.gov (United States)

    Reina, Nicolas; Cavaignac, Etienne; Trousdale, William H; Laffosse, Jean-Michel; Braga, José

    2017-06-01

    It is widely hypothesized that mechanical loading, specifically repetitive low-intensity tasks, influences the inner structure of cancellous bone. As such, there is likely a relationship between handedness and bone morphology. The aim of this study is to determine patterns in trabecular bone between dominant and non-dominant hands in modern humans. Seventeen healthy patients between 22 and 32 years old were included in the study. Radial carpal bones (lunate, capitate, scaphoid, trapezium, trapezoid, 1st, 2nd and 3rd metacarpals) were analyzed with high-resolution micro-computed tomography. Additionally, crush and pinch grip were recorded. Factorial analysis indicated that bone volume ratio, trabeculae number (Tb.N), bone surface to volume ratio (BS.BV), body weight, stature and crush grip were all positively correlated with principal components 1 and 2 explaining 78.7% of the variance. Volumetric and trabecular endostructural parameters (BV/TV, BS/BV or Tb.Th, Tb.N) explain the observed inter-individual variability better than anthropometric or clinical parameters. Factors analysis regressions showed correlations between these parameters and the dominant side for crush strength for the lunate (r 2 = 0.640, P modern human wrist. © 2017 Anatomical Society.

  8. Hand Gesture Recognition Using Ultrasonic Waves

    KAUST Repository

    AlSharif, Mohammed Hussain

    2016-04-01

    Gesturing is a natural way of communication between people and is used in our everyday conversations. Hand gesture recognition systems are used in many applications in a wide variety of fields, such as mobile phone applications, smart TVs, video gaming, etc. With the advances in human-computer interaction technology, gesture recognition is becoming an active research area. There are two types of devices to detect gestures; contact based devices and contactless devices. Using ultrasonic waves for determining gestures is one of the ways that is employed in contactless devices. Hand gesture recognition utilizing ultrasonic waves will be the focus of this thesis work. This thesis presents a new method for detecting and classifying a predefined set of hand gestures using a single ultrasonic transmitter and a single ultrasonic receiver. This method uses a linear frequency modulated ultrasonic signal. The ultrasonic signal is designed to meet the project requirements such as the update rate, the range of detection, etc. Also, it needs to overcome hardware limitations such as the limited output power, transmitter, and receiver bandwidth, etc. The method can be adapted to other hardware setups. Gestures are identified based on two main features; range estimation of the moving hand and received signal strength (RSS). These two factors are estimated using two simple methods; channel impulse response (CIR) and cross correlation (CC) of the reflected ultrasonic signal from the gesturing hand. A customized simple hardware setup was used to classify a set of hand gestures with high accuracy. The detection and classification were done using methods of low computational cost. This makes the proposed method to have a great potential for the implementation in many devices including laptops and mobile phones. The predefined set of gestures can be used for many control applications.

  9. A second dihydroorotate dehydrogenase (Type A) of the human pathogen Enterococcus faecalis: expression, purification, and steady-state kinetic mechanism.

    Science.gov (United States)

    Marcinkeviciene, J; Jiang, W; Locke, G; Kopcho, L M; Rogers, M J; Copeland, R A

    2000-05-01

    We report the identification, expression, and characterization of a second Dihydroorotate dehydrogenase (DHODase A) from the human pathogen Enterococcus faecalis. The enzyme consists of a polypeptide chain of 322 amino acids that shares 68% identity with the cognate type A enzyme from the bacterium Lactococcus lactis. E. faecalis DHODase A catalyzed the oxidation of l-dihydroorotate while reducing a number of substrates, including fumarate, coenzyme Q(0), and menadione. The steady-state kinetic mechanism has been determined with menadione as an oxidizing substrate at pH 7.5. Initial velocity and product inhibition data suggest that the enzyme follows a two-site nonclassical ping-pong kinetic mechanism. The absorbance of the active site FMN cofactor is quenched in a concentration-dependent manner by titration with orotate and barbituric acid, two competitive inhibitors with respect to dihydroorotate. In contrast, titration of the enzyme with menadione had no effect on FMN absorbance, consistent with nonoverlapping binding sites for dihyroorotate and menadione, as suggested from the kinetic mechanism. The reductive half-reaction has been shown to be only partially rate limiting, and an attempt to evaluate the slow step in the overall reaction has been made by simulating orotate production under steady-state conditions. Our data indicate that the oxidative half-reaction is a rate-limiting segment, while orotate, most likely, retains significant affinity for the reduced enzyme, as suggested by the product inhibition pattern. Copyright 2000 Academic Press.

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... has been rented. This feature is not available right now. Please try again later. Published on May ... 34 How The Clean Hands - Safe Hands System Works - Duration: 3:38. Clean Hands-Safe Hands 5, ...

  11. Modeling Photo-Bleaching Kinetics to Create High Resolution Maps of Rod Rhodopsin in the Human Retina.

    Directory of Open Access Journals (Sweden)

    Martin Ehler

    Full Text Available We introduce and describe a novel non-invasive in-vivo method for mapping local rod rhodopsin distribution in the human retina over a 30-degree field. Our approach is based on analyzing the brightening of detected lipofuscin autofluorescence within small pixel clusters in registered imaging sequences taken with a commercial 488nm confocal scanning laser ophthalmoscope (cSLO over a 1 minute period. We modeled the kinetics of rhodopsin bleaching by applying variational optimization techniques from applied mathematics. The physical model and the numerical analysis with its implementation are outlined in detail. This new technique enables the creation of spatial maps of the retinal rhodopsin and retinal pigment epithelium (RPE bisretinoid distribution with an ≈ 50μm resolution.

  12. Modeling Photo-Bleaching Kinetics to Create High Resolution Maps of Rod Rhodopsin in the Human Retina

    Science.gov (United States)

    Ehler, Martin; Dobrosotskaya, Julia; Cunningham, Denise; Wong, Wai T.; Chew, Emily Y.; Czaja, Wojtek; Bonner, Robert F.

    2015-01-01

    We introduce and describe a novel non-invasive in-vivo method for mapping local rod rhodopsin distribution in the human retina over a 30-degree field. Our approach is based on analyzing the brightening of detected lipofuscin autofluorescence within small pixel clusters in registered imaging sequences taken with a commercial 488nm confocal scanning laser ophthalmoscope (cSLO) over a 1 minute period. We modeled the kinetics of rhodopsin bleaching by applying variational optimization techniques from applied mathematics. The physical model and the numerical analysis with its implementation are outlined in detail. This new technique enables the creation of spatial maps of the retinal rhodopsin and retinal pigment epithelium (RPE) bisretinoid distribution with an ≈ 50μm resolution. PMID:26196397

  13. Hands in space: gesture interaction with augmented-reality interfaces.

    Science.gov (United States)

    Billinghurst, Mark; Piumsomboon, Tham; Huidong Bai

    2014-01-01

    Researchers at the Human Interface Technology Laboratory New Zealand (HIT Lab NZ) are investigating free-hand gestures for natural interaction with augmented-reality interfaces. They've applied the results to systems for desktop computers and mobile devices.

  14. Mechanical design of a shape memory alloy actuated prosthetic hand.

    Science.gov (United States)

    De Laurentis, Kathryn J; Mavroidis, Constantinos

    2002-01-01

    This paper presents the mechanical design for a new five fingered, twenty degree-of-freedom dexterous hand patterned after human anatomy and actuated by Shape Memory Alloy artificial muscles. Two experimental prototypes of a finger, one fabricated by traditional means and another fabricated by rapid prototyping techniques, are described and used to evaluate the design. An important aspect of the Rapid Prototype technique used here is that this multi-articulated hand will be fabricated in one step, without requiring assembly, while maintaining its desired mobility. The use of Shape Memory Alloy actuators combined with the rapid fabrication of the non-assembly type hand, reduce considerably its weight and fabrication time. Therefore, the focus of this paper is the mechanical design of a dexterous hand that combines Rapid Prototype techniques and smart actuators. The type of robotic hand described in this paper can be utilized for applications requiring low weight, compactness, and dexterity such as prosthetic devices, space and planetary exploration.

  15. The effects of second-hand smoke on biological processes important in atherogenesis

    Directory of Open Access Journals (Sweden)

    Schneider Matthias

    2007-01-01

    Full Text Available Abstract Background Atherosclerosis is the leading cause of death in western societies and cigarette smoke is among the factors that strongly contribute to the development of this disease. The early events in atherogenesis are stimulated on the one hand by cytokines that chemoattract leukocytes and on the other hand by decrease in circulating molecules that protect endothelial cells (ECs from injury. Here we focus our studies on the effects of "second-hand" smoke on atherogenesis. Methods To perform these studies, a smoking system that closely simulates exposure of humans to second-hand smoke was developed and a mouse model system transgenic for human apoB100 was used. These mice have moderate lipid levels that closely mimic human conditions that lead to atherosclerotic plaque formation. Results "Second-hand" cigarette smoke decreases plasma high density lipoprotein levels in the blood and also decreases the ratios between high density lipoprotein and low density lipoprotein, high density lipoprotein and triglyceride, and high density lipoprotein and total cholesterol. This change in lipid profiles causes not only more lipid accumulation in the aorta but also lipid deposition in many of the smaller vessels of the heart and in hepatocytes. In addition, mice exposed to smoke have increased levels of Monocyte Chemoattractant Protein–1 in circulation and in the heart/aorta tissue, have increased macrophages in the arterial walls, and have decreased levels of adiponectin, an EC-protective protein. Also, cytokine arrays revealed that mice exposed to smoke do not undergo the switch from the pro-inflammatory cytokine profile (that develops when the mice are initially exposed to second-hand smoke to the adaptive response. Furthermore, triglyceride levels increase significantly in the liver of smoke-exposed mice. Conclusion Long-term exposure to "second-hand" smoke creates a state of permanent inflammation and an imbalance in the lipid profile that

  16. Whole-brain functional magnetic resonance imaging of human brain during voluntary movements of dominant and subdominant hands

    International Nuclear Information System (INIS)

    Yu Wei; Yan Zixu; Ma Xiaohai; Zhang Zhaoqi; Lin Chongyu; Zang Yufeng; Weng Xuchu

    2003-01-01

    Objective: To identify the neural substrates of voluntary movements of dominant and subdominant hands by using the whole-brain functional magnetic resonance imaging. Methods: Seven right-handed healthy volunteers were scanned at a Sonata 1.5 Tesla magnetic resonance imaging scanner (Siemens) while they were performing the visually instructive movement tasks with their right and left index fingers. Image data were co-registered to correct head motion, spatially normalized according to the standard coordinates, and spatially smoothed with isotopic Guassian Kernel. Statistical parametric maps (activation maps) for right and left hands were generated respectively by cross-correlation analysis. Results: Voluntary movements of the right/dominant hand mainly activated contralateral primary motor cortex (MI), bilateral supplementary motor area (SMA), bilateral second motor area (MII), and ipsilateral cerebellum, whereas movements of the left/subdominant hand additionally elicited activation in contralateral premotor area (PMC). Moreover, activation volumes in SMA and MII during movements of the subdominant hand were significantly larger than those during movements of the dominant hand. Conclusion: A large set of structures in the cerebral cortex and cerebellum is involved in voluntary movements, as revealed by whole brain-based fMRI. Movements of the subdominant hand are more dependent on higher control areas, such as SMA and PMC, comparing to movements of the dominant hand

  17. Neuro-prosthetic interplay. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by M. Santello et al.

    Science.gov (United States)

    Schieber, Marc H.

    2016-07-01

    Control of the human hand has been both difficult to understand scientifically and difficult to emulate technologically. The article by Santello and colleagues in the current issue of Physics of Life Reviews[1] highlights the accelerating pace of interaction between the neuroscience of controlling body movement and the engineering of robotic hands that can be used either autonomously or as part of a motor neuroprosthesis, an artificial body part that moves under control from a human subject's own nervous system. Motor neuroprostheses typically involve a brain-computer interface (BCI) that takes signals from the subject's nervous system or muscles, interprets those signals through a decoding algorithm, and then applies the resulting output to control the artificial device.

  18. Working hard to make a simple definition of synergies. Comment on: "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by Marco Santello et al.

    Science.gov (United States)

    Alessandro, Cristiano; Oliveira Barroso, Filipe; Tresch, Matthew

    2016-07-01

    The paper ;Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands; [1] presents a comprehensive review of the work carried out as part of the EU funded project ;The Hand Embodied;. The work uses the concept of ;synergy; to study the neuromuscular control of the human hand and to design novel robotics systems. The project has been very productive and has made important contributions. We are therefore confident that it will lead to further advancements and experiments in the future.

  19. Video observation of hand hygiene practices during routine companion animal appointments and the effect of a poster intervention on hand hygiene compliance

    Science.gov (United States)

    2014-01-01

    Background Hand hygiene is considered one of the most important infection control measures in human healthcare settings, but there is little information available regarding hand hygiene frequency and technique used in veterinary clinics. The objectives of this study were to describe hand hygiene practices associated with routine appointments in companion animal clinics in Ontario, and the effectiveness of a poster campaign to improve hand hygiene compliance. Results Observation of hand hygiene practices was performed in 51 clinics for approximately 3 weeks each using 2 small wireless surveillance cameras: one in an exam room, and one in the most likely location for hand hygiene to be performed outside the exam room following an appointment. Data from 38 clinics were included in the final analysis, including 449 individuals, 1139 appointments before and after the poster intervention, and 10894 hand hygiene opportunities. Overall hand hygiene compliance was 14% (1473/10894), while before and after patient contact compliance was 3% (123/4377) and 26% (1145/4377), respectively. Soap and water was used for 87% (1182/1353) of observed hand hygiene attempts with a mean contact time of 4 s (median 2 s, range 1-49 s), while alcohol-based hand rub (ABHR) was used for 7% (98/1353) of attempts with a mean contact time of 8 s (median 7 s, range 1-30 s). The presence of the posters had no significant effect on compliance, although some staff reported that they felt the posters did increase their personal awareness of the need to perform hand hygiene, and the posters had some effect on product contact times. Conclusions Overall hand hygiene compliance in veterinary clinics in this study was low, and contact time with hand hygiene products was frequently below current recommendations. Use of ABHR was low despite its advantages over hand washing and availability in the majority of clinics. The poster campaign had a limited effect on its own, but could still be used as a

  20. Experiments and kinematics analysis of a hand rehabilitation exoskeleton with circuitous joints.

    Science.gov (United States)

    Zhang, Fuhai; Fu, Yili; Zhang, Qinchao; Wang, Shuguo

    2015-01-01

    Aiming at the hand rehabilitation of stroke patients, a wearable hand exoskeleton with circuitous joint is proposed. The circuitous joint adopts the symmetric pinion and rack mechanism (SPRM) with the parallel mechanism. The exoskeleton finger is a serial mechanism composed of three closed-chain SPRM joints in series. The kinematic equations of the open chain of the finger and the closed chains of the SPRM joints were built to analyze the kinematics of the hand rehabilitation exoskeleton. The experimental setup of the hand rehabilitation exoskeleton was built and the continuous passive motion (CPM) rehabilitation experiment and the test of human-robot interaction force measurement were conducted. Experiment results show that the mechanical design of the hand rehabilitation robot is reasonable and that the kinematic analysis is correct, thus the exoskeleton can be used for the hand rehabilitation of stroke patients.

  1. Leakage and scattered radiation from hand-held dental x-ray unit

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2007-01-01

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR ΙΙΙ was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR ΙΙΙ was exposed with portable X-ray unit 6.39 μGy, and the mean dose with fixed X-ray unit 3.03 μGy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 μGy and with fixed X-ray unit the mean dose was 0.68 μGy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography

  2. Leakage and scattered radiation from hand-held dental x-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2007-06-15

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR {iota}{iota}{iota} was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR {iota}{iota}{iota} was exposed with portable X-ray unit 6.39 {mu}Gy, and the mean dose with fixed X-ray unit 3.03 {mu}Gy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 {mu}Gy and with fixed X-ray unit the mean dose was 0.68 {mu}Gy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  3. Cold-induced vasoconstriction at forearm and hand skin sites: the effect of age

    NARCIS (Netherlands)

    Kingma, B.R.M.; Frijns, A.J.H.; Saris, W.H.M.; Steenhoven, van A.A.; Marken Lichtenbelt, van W.D.

    2010-01-01

    During mild cold exposure, elderly are at risk of hypothermia. In humans, glabrous skin at the hands is well adapted as a heat exchanger. Evidence exists that elderly show equal vasoconstriction due to local cooling at the ventral forearm, yet no age effects on vasoconstriction at hand skin have

  4. Hand biometric recognition based on fused hand geometry and vascular patterns.

    Science.gov (United States)

    Park, GiTae; Kim, Soowon

    2013-02-28

    A hand biometric authentication method based on measurements of the user's hand geometry and vascular pattern is proposed. To acquire the hand geometry, the thickness of the side view of the hand, the K-curvature with a hand-shaped chain code, the lengths and angles of the finger valleys, and the lengths and profiles of the fingers were used, and for the vascular pattern, the direction-based vascular-pattern extraction method was used, and thus, a new multimodal biometric approach is proposed. The proposed multimodal biometric system uses only one image to extract the feature points. This system can be configured for low-cost devices. Our multimodal biometric-approach hand-geometry (the side view of the hand and the back of hand) and vascular-pattern recognition method performs at the score level. The results of our study showed that the equal error rate of the proposed system was 0.06%.

  5. Estradiol stimulation of inositolphospholipid metabolism in human endometrial fibroblasts

    International Nuclear Information System (INIS)

    Iida, K.; Imai, A.; Tamaya, T.

    1989-01-01

    Stimulated inositolphospholipid turnover has been proposed to constitute a signal-transducing mechanism in many cell types. To determine the inositolphospholipid turnover during stimulation by 17 beta-estradiol, the turnover kinetics of phospholipids was investigated in human endometrial fibroblasts. In cells incubated with [ 32 P] phosphate for 1 h, estradiol rapidly and persisitently (for at least 30 min) enhanced the rate of 32 P-labeling of phosphatidic acid (PA). On the other hand, after a lag time of 5 min, 32 P-labeling of phosphatidylinositol (PI) was also increased also. These sequential 32 P-labeling of PA and PI demonstrated that inositolphospholipid turnover was stimulated in fibroblasts exposed to estradiol. The rapid estrogen-stimulated inositolphospholipid turnover may not be through the mechanism associated with classical action of estrogen

  6. The Hand: Shall We Ever Understand How it Works?

    Science.gov (United States)

    Latash, Mark L

    2015-04-01

    The target article presents a review of the neural control of the human hand. The review emphasizes the physical approach to motor control. It focuses on such concepts as equilibrium-point control, control with referent body configurations, uncontrolled manifold hypothesis, principle of abundance, hierarchical control, multidigit synergies, and anticipatory synergy adjustments. Changes in aspects of the hand neural control with age and neurological disorder are discussed. The target article is followed by six commentaries written by Alexander Aruin, Kelly Cole, Monica Perez, Robert Sainburg, Marco Sanello, and Wei Zhang.

  7. Gaucher disease: Physical, kinetic and immunologic investigations of human and canine acid β-glucosidase

    International Nuclear Information System (INIS)

    Fabbro, D.E.

    1988-01-01

    Kinetic and immunologic techniques were developed to investigate the nature of the acid β-glucosidase (β-Glc) defects which results in human and canine Gaucher disease (GD). Two new affinity columns, using the potent inhibitors of β-Glc (N-alkyl-deoxynojirimycins) as affinity ligands, were synthesized and methods were developed to obtain homogeneous β-Glc from normal human placenta. Polyclonal and monoclonal (representing 14 different epitopes from 18 clones) antibodies were produced to the pure normal β-Glc. Monospecific polyclonal IgG and tritiated-bromo-conduritol B epoxide ([ 3 H]Br-CBE), a specific covalent active site directed inhibitor of β-Glc, were used to quantitate the functional catalytic sites in normal and Type 1 Ashkenazi Jewish GD (AJGD) enzyme preparations: The k cat values for several new substrates with the mutant enzymes from spleen were about 1.5-fold less than the respective normal enzyme, indicating a nearly normal catalytic capacity of the mutant enzymes. Immunoblotting studies with polyclonal or several monoclonal antibodies indicated three molecular forms of β-Glc (M r = 67,000, 62,000 to 65,000 and 58,000) in fibroblast extracts from normals and Type 1 AJGD patients. In comparison, only one form of cross-reacting immunologic material (CRIM) was detected in fibroblast extracts from Types 2 and 3 or several non-Jewish Type 1 GD patients

  8. Kinetic chains: a review of the concept and its clinical applications.

    Science.gov (United States)

    Karandikar, Ninad; Vargas, Oscar O Ortiz

    2011-08-01

    During the past decade, our understanding of biomechanics and its importance in rehabilitation has advanced significantly. The kinetic chain, a concept borrowed from engineering, has helped us better understand the underlying physiology of human movement. This understanding, in turn, has facilitated the development of new and more rational rehabilitation strategies. The kinetic chain concept has application in a wide spectrum of clinical conditions, including musculoskeletal medicine, sports medicine, and neurorehabilitation, as well as prosthetics and orthotics. The purpose of this review is to provide insights into the biomechanics related to the concept of kinetic chains, with a specific focus on closed kinetic chains and its clinical applications in rehabilitation. Copyright © 2011 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  9. Hand Hygiene With Alcohol-Based Hand Rub: How Long Is Long Enough?

    Science.gov (United States)

    Pires, Daniela; Soule, Hervé; Bellissimo-Rodrigues, Fernando; Gayet-Ageron, Angèle; Pittet, Didier

    2017-05-01

    BACKGROUND Hand hygiene is the core element of infection prevention and control. The optimal hand-hygiene gesture, however, remains poorly defined. OBJECTIVE We aimed to evaluate the influence of hand-rubbing duration on the reduction of bacterial counts on the hands of healthcare personnel (HCP). METHODS We performed an experimental study based on the European Norm 1500. Hand rubbing was performed for 10, 15, 20, 30, 45, or 60 seconds, according to the WHO technique using 3 mL alcohol-based hand rub. Hand contamination with E. coli ATCC 10536 was followed by hand rubbing and sampling. A generalized linear mixed model with a random effect on the subject adjusted for hand size and gender was used to analyze the reduction in bacterial counts after each hand-rubbing action. In addition, hand-rubbing durations of 15 and 30 seconds were compared to assert non-inferiority (0.6 log10). RESULTS In total, 32 HCP performed 123 trials. All durations of hand rubbing led to significant reductions in bacterial counts (Phand rubbing were not significantly different from those obtained after 30 seconds. The mean bacterial reduction after 15 seconds of hand rubbing was 0.11 log10 lower (95% CI, -0.46 to 0.24) than after 30 seconds, demonstrating non-inferiority. CONCLUSIONS Hand rubbing for 15 seconds was not inferior to 30 seconds in reducing bacterial counts on hands under the described experimental conditions. There was no gain in reducing bacterial counts from hand rubbing longer than 30 seconds. Further studies are needed to assess the clinical significance of our findings. Infect Control Hosp Epidemiol 2017;38:547-552.

  10. Exploring the Invisible Renormalon Renormalization of the Heavy-Quark Kinetic Energy

    CERN Document Server

    Neubert, M

    1997-01-01

    Using the virial theorem of the heavy-quark effective theory, we show that the mixing of the operator for the heavy-quark kinetic energy with the identity operator is forbidden at the one-loop order by Lorentz invariance. This explains why such a mixing was not observed in several one-loop calculations using regularization schemes with a Lorentz-invariant UV regulator, and why no UV renormalon singularity was found in the matrix elements of the kinetic operator in the bubble approximation (the ``invisible renormalon''). On the other hand, we show that the mixing is not protected in general by any symmetry, and it indeed occurs at the two-loop order. This implies that the parameter $\\lambda_1^H$ of the heavy-quark effective theory is not directly a physical quantity, but requires a non-perturbative subtraction.

  11. Hand in Hand - SEI Programmes for School Staff

    DEFF Research Database (Denmark)

    Nielsen, Birgitte Lund; Réol, Lise Andersen; Laursen, Hilmar Dyrborg

    2017-01-01

    This catalogue of research in the field of SEI programmes for the school staff’s and teachers’ SEI competencies is based on a review performed by the main researchers Birgitte Lund Nielsen, Lise Andersen Réol and Hilmar Dyrborg Laursen, VIA University College, Denmark, but discussed by the entire...... team of Hand in Hand partner countries and researchers. The aim was to identify the central aspects and elements concerning successful implementation, and school staff’s development of professional competencies in the specific field of supporting students’ social, emotional and intercultural (SEI......) competencies. Abstract: Framed by the EU-project Hand in Hand focusing on Social, Emotional and Intercultural (SEI) competencies among students and school staff, the paper discusses implementation and professional competencies based on a research review. The following five topics were identified: 1...

  12. Mechanisms responsible for the acceleration of pulmonary V̇O2 on-kinetics in humans after prolonged endurance training.

    Science.gov (United States)

    Zoladz, Jerzy A; Grassi, Bruno; Majerczak, Joanna; Szkutnik, Zbigniew; Korostyński, Michal; Grandys, Marcin; Jarmuszkiewicz, Wieslawa; Korzeniewski, Bernard

    2014-11-01

    The effect of prolonged endurance training on the pulmonary V̇O2 on- and off-kinetics in humans, in relation to muscle mitochondria biogenesis, is investigated. Eleven untrained physically active men (means±SD: age 22.4±1.5 years, V̇O2peak 3,187±479 ml/min) performed endurance cycling training (4 sessions per week) lasting 20 wk. Training shortened τp of the pulmonary V̇O2 on-kinetics during moderate-intensity cycling by ∼19% from 28.3±5.2 to 23.0±4.0 s (P=0.005). τp of the pulmonary V̇O2 off-kinetics decreased by ∼11% from 33.7±7.2 to 30.0±6.6 (P=0.02). Training increased (in vastus lateralis muscle) mitochondrial DNA copy number in relation to nuclear DNA (mtDNA/nDNA) (+53%) (P=0.014), maximal citrate synthase (CS) activity (+38%), and CS protein content (+38%) (P=0.004), whereas maximal cytochrome c oxidase (COX) activity after training tended to be only slightly (+5%) elevated (P=0.08). By applying to the experimental data, our computer model of oxidative phosphorylation (OXPHOS) and using metabolic control analysis, we argue that COX activity is a much better measure of OXPHOS intensity than CS activity. According to the model, in the present study a training-induced increase in OXPHOS activity accounted for about 0-10% of the decrease in τp of muscle and pulmonary V̇O2 for the on-transient, whereas the remaining 90-100% is caused by an increase in each-step parallel activation of OXPHOS. Copyright © 2014 the American Physiological Society.

  13. VARIABLE STIFFNESS HAND PROSTHESIS: A SYSTEMATIC REVIEW

    Directory of Open Access Journals (Sweden)

    S. Cecilia Tapia-Siles

    2017-06-01

    Full Text Available Prosthetics is an important field in engineering due to the large number of amputees worldwide and the associated problems such as limited functionality of the state of the art. An important functionality of the human hand is its capability of adjusting the stiffness of the joints depending on the currently performed task. For the development of new technology it is important to understand the limitations of existing resources. As part of our efforts to develop a variable stiffness grasper for developing countries a systematic review was performed covering technology of body powered and myoelectric hand prosthesis. Focus of the review is readiness of prosthetic hands regarding their capability of controlling the stiffness of the end effector. Publications sourced through three different digital libraries were systematically reviewed on the basis of the PRISMA standard. We present a search strategy as well as the PRISMA assessment of the resulting records which covered 321 publications. The records were assessed and the results are presented for the ability of devices to control their joint stiffness. The review indicates that body powered prosthesis are preferred to myoelectric hands due to the reduced cost, the simplicity of use and because of their inherent ability to provide feedback to the user. Stiffness control was identified but has not been fully covered in the current state of the art. In addition we summarise the identified requirements on prosthetic hands as well as related information which can support the development of new prosthetics.

  14. Hand Biometric Recognition Based on Fused Hand Geometry and Vascular Patterns

    Science.gov (United States)

    Park, GiTae; Kim, Soowon

    2013-01-01

    A hand biometric authentication method based on measurements of the user's hand geometry and vascular pattern is proposed. To acquire the hand geometry, the thickness of the side view of the hand, the K-curvature with a hand-shaped chain code, the lengths and angles of the finger valleys, and the lengths and profiles of the fingers were used, and for the vascular pattern, the direction-based vascular-pattern extraction method was used, and thus, a new multimodal biometric approach is proposed. The proposed multimodal biometric system uses only one image to extract the feature points. This system can be configured for low-cost devices. Our multimodal biometric-approach hand-geometry (the side view of the hand and the back of hand) and vascular-pattern recognition method performs at the score level. The results of our study showed that the equal error rate of the proposed system was 0.06%. PMID:23449119

  15. Formalization of the kinetics for autocatalytic dissolutions. Focus on the dissolution of uranium dioxide in nitric medium

    International Nuclear Information System (INIS)

    Charlier, F.; Canion, D.; Gravinese, A.; Magnaldo, A.; Lalleman, S.; Borda, G.; Schaer, E.

    2017-01-01

    Uranium dioxide dissolution in nitric acid is a complex reaction. On the one hand, the dissolution produces nitrous oxides (NOX), which makes it a triphasic reaction. On the other hand, one of the products accelerates the kinetic rate; the reaction is hence called autocatalytic.The kinetics for these kinds of reactions need to be formalized in order to optimize and design innovative dissolution reactors. In this work, the kinetics rates have been measured by optical microscopy using a single particle approach. The advantages of this analytical technique are an easier management of species transport in solution and a precise following of the dissolution rate. The global rate is well described by a mechanism considering two steps: a non-catalyzed reaction, where the catalyst concentration has no influence on the dissolution rate, and a catalyzed reaction. The mass transfer rate of the catalyst was quantified in order to discriminate when the reaction was influenced by catalyst accumulated in the boundary layer or uncatalyzed. This first approximation described well the sigmoid dissolution curve profile. Moreover, experiments showed that solutions filled with catalyst proved to lose reactivity over time. Results pointed out that the higher the liquid-gas exchanges, the faster the kinetic rate decreases with time. Thus, it was demonstrated, for the first time, that there is a link between catalyst and nitrous oxides. The outcome of this study leads to new ways for improving the design of dissolvers. Gas-liquid exchanges are indeed a lever to impact dissolution rates. Temperature and catalyst concentration can be optimized to reduce residence times in dissolvers. (authors)

  16. Kinetic Typography

    DEFF Research Database (Denmark)

    van Leeuwen, Theo; Djonov, Emilia

    2014-01-01

    After discussing broad cultural drivers behind the development of kinetic typography, the chapter outlines an approach to analysing kinetic typography which is based on Halliday's theory of transitivity, as applied by Kress and Van Leeuwen to visual images.......After discussing broad cultural drivers behind the development of kinetic typography, the chapter outlines an approach to analysing kinetic typography which is based on Halliday's theory of transitivity, as applied by Kress and Van Leeuwen to visual images....

  17. A New Profile Shape Matching Stereovision Algorithm for Real-time Human Pose and Hand Gesture Recognition

    Directory of Open Access Journals (Sweden)

    Dong Zhang

    2014-02-01

    Full Text Available This paper presents a new profile shape matching stereovision algorithm that is designed to extract 3D information in real time. This algorithm obtains 3D information by matching profile intensity shapes of each corresponding row of the stereo image pair. It detects the corresponding matching patterns of the intensity profile rather than the intensity values of individual pixels or pixels in a small neighbourhood. This approach reduces the effect of the intensity and colour variations caused by lighting differences. As with all real-time vision algorithms, there is always a trade-off between accuracy and processing speed. This algorithm achieves a balance between the two to produce accurate results for real-time applications. To demonstrate its performance, the proposed algorithm is tested for human pose and hand gesture recognition to control a smart phone and an entertainment system.

  18. Guideline Implementation: Hand Hygiene.

    Science.gov (United States)

    Goldberg, Judith L

    2017-02-01

    Performing proper hand hygiene and surgical hand antisepsis is essential to reducing the rates of health care-associated infections, including surgical site infections. The updated AORN "Guideline for hand hygiene" provides guidance on hand hygiene and surgical hand antisepsis, the wearing of fingernail polish and artificial nails, proper skin care to prevent dermatitis, the wearing of jewelry, hand hygiene product selection, and quality assurance and performance improvement considerations. This article focuses on key points of the guideline to help perioperative personnel make informed decisions about hand hygiene and surgical hand antisepsis. The key points address the necessity of keeping fingernails and skin healthy, not wearing jewelry on the hands or wrists in the perioperative area, properly performing hand hygiene and surgical hand antisepsis, and involving patients and visitors in hand hygiene initiatives. Perioperative RNs should review the complete guideline for additional information and for guidance when writing and updating policies and procedures. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  19. FOCUS ON HAND WASHING Yakubu Tahir Maigari Departm

    African Journals Online (AJOL)

    HP

    2014-10-24

    Oct 24, 2014 ... Management and Social Sciences, Federal University Kashere,. Gombe State ... Peace can also be maintained with fellow human beings through ... talent and skill to build a mighty ship with which he and his people took .... One important aspect of Islamic rituals where washing of hands is prominent is ...

  20. IMPORTANCE OF KINETIC MEASURES IN TRAJECTORY PREDICTION WITH OPTIMAL CONTROL

    Directory of Open Access Journals (Sweden)

    Ömer GÜNDOĞDU

    2001-02-01

    Full Text Available A two-dimensional sagittally symmetric human-body model was established to simulate an optimal trajectory for manual material handling tasks. Nonlinear control techniques and genetic algorithms were utilized in the optimizations to explore optimal lifting patterns. The simulation results were then compared with the experimental data. Since the kinetic measures such as joint reactions and moments are vital parameters in injury determination, the importance of comparing kinetic measures rather than kinematical ones was emphasized.

  1. Kinetic study and thermal decomposition behavior of viscoelastic memory foam

    International Nuclear Information System (INIS)

    Garrido, María A.; Font, Rafael; Conesa, Juan A.

    2016-01-01

    Highlights: • The thermal degradation has been studied under three different atmospheres. • Pyrolysis and combustion kinetic models have been proposed. • Evolved products under different atmospheres have been analyzed by TG-FTIR and TG-MS. - Abstract: A systematic investigation of the thermal decomposition of viscoelastic memory foam (VMF) was performed using thermogravimetric analysis (TGA) to obtain the kinetic parameters, and thermogravimetric analysis coupled to Fourier Transformed Infrared Spectrometry (TGA-FTIR) and thermogravimetric analysis coupled to Mass Spectrometry (TGA-MS) to obtain detailed information of evolved products on pyrolysis and oxidative degradations. Two consecutive nth-order reactions were employed to correlate the experimental data from dynamic and isothermal runs performed at three different heating rates (5, 10 and 20 K/min) under an inert atmosphere. On the other hand, for the kinetic study of the oxidative decomposition, the data from combustion (synthetic air) and poor oxygen combustion (N_2:O_2 = 9:1) runs, at three heating rates and under dynamic and isothermal conditions, were correlated simultaneously. A kinetic model consisting of three consecutive reactions presented a really good correlation in all runs. TGA-FTIR analysis showed that the main gases released during the pyrolysis of VMF were determined as ether and aliphatic hydrocarbons, whereas in combustion apart from the previous gases, aldehydes, amines and CO_2 have also been detected as the main gases. These results were confirmed by the TGA-MS.

  2. Inspections of Hand Washing Supplies and Hand Sanitizer in Public Schools

    Science.gov (United States)

    Ramos, Mary M.; Blea, Mary; Trujillo, Rebecca; Greenberg, Cynthia

    2010-01-01

    Hand washing and hand antisepsis are proven infection control measures in the school setting, yet barriers such as lack of soap, paper towels, and hand sanitizer can hinder compliance. This pilot study measured the prevalence of hand cleaning supplies in public schools. Ten school districts (93 schools) participated in school nurse inspections. In…

  3. Kinetic studies of the inhibition of a human liver 3 alpha-hydroxysteroid/dihydrodiol dehydrogenase isozyme by bile acids and anti-inflammatory drugs.

    Science.gov (United States)

    Miyabe, Y; Amano, T; Deyashiki, Y; Hara, A; Tsukada, F

    1995-01-01

    We have investigated the steady-state kinetics for a cytosolic 3 alpha-hydroxysteroid/dihydrodiol dehydrogenase isozyme of human liver and its inhibition by several bile acids and anti-inflammatory drugs such as indomethacin, flufemanic acid and naproxen. Initial velocity and product inhibition studies performed in the NADP(+)-linked (S)-1-indanol oxidation at pH 7.4 were consistent with a sequential ordered mechanism in which NADP+ binds first and leaves last. The bile acids and drugs, competitive inhibitors with respect to the alcohol substrate, exhibited uncompetitive inhibition with respect to the coenzyme, with Ki values less than 1 microM, whereas indomethacin exhibited noncompetitive inhibition (Ki < 24 microM). The kinetics of the inhibition by a mixture of the two inhibitors suggests that bile acids and drugs, except indomethacin, bind to overlapping sites at the active center of the enzyme-coenzyme binary complex.

  4. Effect of hand sanitizer location on hand hygiene compliance.

    Science.gov (United States)

    Cure, Laila; Van Enk, Richard

    2015-09-01

    Hand hygiene is the most important intervention to prevent infection in hospitals. Health care workers should clean their hands at least before and after contact with patients. Hand sanitizer dispensers are important to support hand hygiene because they can be made available throughout hospital units. The aim of this study was to determine whether the usability of sanitizer dispensers correlates with compliance of staff in using the sanitizer in a hospital. This study took place in a Midwest, 404-bed, private, nonprofit community hospital with 15 inpatient care units in addition to several ambulatory units. The usability and standardization of sanitizers in 12 participating inpatient units were evaluated. The hospital measured compliance of staff with hand hygiene as part of their quality improvement program. Data from 2010-2012 were analyzed to measure the relationship between compliance and usability using mixed-effects logistic regression models. The total usability score (P = .0046), visibility (P = .003), and accessibility of the sanitizer on entrance to the patient room (P = .00055) were statistically associated with higher observed compliance rates. Standardization alone showed no significant impact on observed compliance (P = .37). Hand hygiene compliance can be influenced by visibility and accessibility of dispensers. The sanitizer location should be part of multifaceted interventions to improve hand hygiene. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Quantification of Hand Motor Symptoms in Parkinson's Disease: A Proof-of-Principle Study Using Inertial and Force Sensors.

    Science.gov (United States)

    van den Noort, Josien C; Verhagen, Rens; van Dijk, Kees J; Veltink, Peter H; Vos, Michelle C P M; de Bie, Rob M A; Bour, Lo J; Heida, Ciska T

    2017-10-01

    This proof-of-principle study describes the methodology and explores and demonstrates the applicability of a system, existing of miniature inertial sensors on the hand and a separate force sensor, to objectively quantify hand motor symptoms in patients with Parkinson's disease (PD) in a clinical setting (off- and on-medication condition). Four PD patients were measured in off- and on- dopaminergic medication condition. Finger tapping, rapid hand opening/closing, hand pro/supination, tremor during rest, mental task and kinetic task, and wrist rigidity movements were measured with the system (called the PowerGlove). To demonstrate applicability, various outcome parameters of measured hand motor symptoms of the patients in off- vs. on-medication condition are presented. The methodology described and results presented show applicability of the PowerGlove in a clinical research setting, to objectively quantify hand bradykinesia, tremor and rigidity in PD patients, using a single system. The PowerGlove measured a difference in off- vs. on-medication condition in all tasks in the presented patients with most of its outcome parameters. Further study into the validity and reliability of the outcome parameters is required in a larger cohort of patients, to arrive at an optimal set of parameters that can assist in clinical evaluation and decision-making.

  6. Die Sprache der Hande zu den Handen sprechen (Talking the Language of the Hands to the Hands). DB-LINK.

    Science.gov (United States)

    Miles, Barbara

    This paper examines the importance of hands for the person who is deafblind, reviews hand development, and identifies specific teaching skills that facilitate hand development and expressiveness in persons who are deafblind. It notes that the hands of a deafblind individual serve not only as tools but also as sense organs (to compensate for their…

  7. Human machine interaction: The special role for human unconscious emotional information processing

    NARCIS (Netherlands)

    Noort, M.W.M.L. van den; Hugdahl, K.; Bosch, M.P.C.

    2005-01-01

    The nature of (un)conscious human emotional information processing remains a great mystery. On the one hand, classical models view human conscious emotional information processing as computation among the brain’s neurons but fail to address its enigmatic features. On the other hand, quantum

  8. Hand hygiene strategies

    OpenAIRE

    Yazaji, Eskandar Alex

    2011-01-01

    Hand hygiene is one of the major players in preventing healthcare associated infections. However, healthcare workers compliance with hand hygiene continues to be a challenge. This article will address strategies to help improving hand hygiene compliance. Keywords: hand hygiene; healthcare associated infections; multidisciplinary program; system change; accountability; education; feedback(Published: 18 July 2011)Citation: Journal of Community Hospital Internal Medicine Perspectives 2011, 1: 72...

  9. An Efficient Solution for Hand Gesture Recognition from Video Sequence

    Directory of Open Access Journals (Sweden)

    PRODAN, R.-C.

    2012-08-01

    Full Text Available The paper describes a system of hand gesture recognition by image processing for human robot interaction. The recognition and interpretation of the hand postures acquired through a video camera allow the control of the robotic arm activity: motion - translation and rotation in 3D - and tightening/releasing the clamp. A gesture dictionary was defined and heuristic algorithms for recognition were developed and tested. The system can be used for academic and industrial purposes, especially for those activities where the movements of the robotic arm were not previously scheduled, for training the robot easier than using a remote control. Besides the gesture dictionary, the novelty of the paper consists in a new technique for detecting the relative positions of the fingers in order to recognize the various hand postures, and in the achievement of a robust system for controlling robots by postures of the hands.

  10. Cold-induced vasoconstriction at forearm and hand skin sites: the effect of age

    OpenAIRE

    Kingma, B.R.M.; Frijns, A.J.H.; Saris, W.H.M.; Steenhoven, van, A.A.; Marken Lichtenbelt, van, W.D.

    2010-01-01

    During mild cold exposure, elderly are at risk of hypothermia. In humans, glabrous skin at the hands is well adapted as a heat exchanger. Evidence exists that elderly show equal vasoconstriction due to local cooling at the ventral forearm, yet no age effects on vasoconstriction at hand skin have been studied. Here, we tested the hypotheses that at hand sites (a) elderly show equal vasoconstriction due to local cooling and (b) elderly show reduced response to noradrenergic stimuli. Skin perfus...

  11. Comparative antibacterial effectiveness of alcohol and herbal based commercially available hand antiseptics

    Directory of Open Access Journals (Sweden)

    K Vipin Jain

    2013-01-01

    Full Text Available Background: Human skin is a reservoir of numerous microorganisms. Even though hand washing with soap and water alone reduces the microbial load, the complementary uses of hand antiseptics enhance the antimicrobial effect. Aim: To compare the antimicrobial effectiveness of two commercially available hand antiseptics, routinely used in dental practice, after hand washing with antiseptic soap. Method: A clinical trial with cross over design was carried out on 12 health care workers (HCWs. The antibacterial effectiveness of two hand antiseptics (Alcohol based -Sterillium and Herbal Based-Himalaya′s ′Pure Hands′ compared using fingerprint contact sampling on blood agar. Bacterial samples were obtained before and after hand washing (with antiseptic soap and after hand disinfection. The data was tabulated and analyzed using one way ANOVA and Tukey′s post hoc test for pair-wise comparison. Result: There was a slight decrease in the Colony forming units (CFUs count following use of antiseptic soap when compared to the baseline values. A statistically significant reduction (p<0.000 in the CFUs count was seen following use of both hand antiseptics but the mean number of CFUs reduction was more in case of alcohol based hand antiseptic(sterillium than herbal based hand antiseptic(Himalaya′s ′PureHands". Conclusion: Using alcohol based antiseptic soap before hygienic hand disinfection will provide maximum benefit in reducing the microbial count.

  12. The uptake kinetics and immunotoxic effects of microcystin-LR in human and chicken peripheral blood lymphocytes in vitro

    International Nuclear Information System (INIS)

    Lankoff, Anna; Carmichael, Wayne W.; Grasman, Keith A.; Yuan, Moucun

    2004-01-01

    Microcystin-LR is a cyanobacterial heptapeptide that presents acute and chronic hazards to animal and human health. We investigated the influence of this toxin on human and chicken immune system modulation in vitro. Peripheral blood lymphocytes were treated with microcystin-LR at environmentally relevant doses of 1, 10 and 25 μg/ml for 12, 24, 48, 72 h (for proliferation assay cells were treated for 72 h). T-cell and B-cell proliferation as well as apoptosis and necrosis were determined in human and chicken samples. IL-2 and IL-6 production by human lymphocytes also was measured. In addition, uptake kinetics of microcystin-LR into human and chicken peripheral blood lymphocytes were calculated by Liquid Chromatography (LS) /Mass Spectrometry (MS) analysis. At the highest dose microcystin-LR decreased T-cell proliferation and all doses of microcystin-LR inhibited B-cell proliferation. The frequency of apoptotic and necrotic cells increased in a dose and time-dependent manner. Human lymphocytes responded to stimulation with microcystin-LR by increased production of IL-6 and decreased production of IL-2. Human lymphocytes were able to uptake from 0.014 to 1.663 μg/ml and chicken lymphocytes from 0.035 to 1.733 μg/ml of the microcystin-LR added to the cultures, depending on the treatment time and dose. In conclusion, microcystin-LR acted as an immunomodulator in cytokine production and down-regulated lymphocyte functions by induction of apoptosis and necrosis. However, further studies dealing with the influence of microcystin-LR on expression cytokine genes and transcription factors are necessary to confirm these hypotheses

  13. A bio-inspired design of a hand robotic exoskeleton for rehabilitation

    Science.gov (United States)

    Ong, Aira Patrice R.; Bugtai, Nilo T.

    2018-02-01

    This paper presents the methodology for the design of a five-degree of freedom wearable robotic exoskeleton for hand rehabilitation. The design is inspired by the biological structure and mechanism of the human hand. One of the distinct features of the device is the cable-driven actuation, which provides the flexion and extension motion. A prototype of the orthotic device has been developed to prove the model of the system and has been tested in a 3D printed mechanical hand. The result showed that the proposed device was consistent with the requirements of bionics and was able to demonstrate the flexion and extension of the system.

  14. R-Limonene metabolism in humans and metabolite kinetics after oral administration.

    Science.gov (United States)

    Schmidt, Lukas; Göen, Thomas

    2017-03-01

    We studied the R-limonene (LMN) metabolism and elimination kinetics in a human in vivo study. Four volunteers were orally exposed to a single LMN dose of 100-130 µg kg -1 bw. In each case, one pre-exposure and subsequently all 24 h post-exposure urine samples were collected. From two subjects, blood samples were drawn up to 5 h after exposure. The parent compound was analysed in blood using headspace GC-MS. The metabolites cis- and trans-carveol (cCAR), perillyl alcohol (POH), perillic acid (PA), limonene-1,2-diol (LMN-1,2-OH), and limonene-8,9-diol (LMN-8,9-OH) were quantified in both blood and urine using GC-PCI-MS/MS. Moreover, GC-PCI-MS full-scan experiments were applied for identification of unknown metabolites in urine. In both matrices, metabolites reached maximum concentrations 1-2 h post-exposure followed by rapid elimination with half-lives of 0.7-2.5 h. In relation to the other metabolites, LMN-1,2-OH was eliminated slowest. Nonetheless, overall renal metabolite elimination was completed within the 24-h observation period. The metabolite amounts excreted via urine corresponded to 0.2 % (cCAR), 0.2 % (tCAR), <0.1 % (POH), 2.0 % (PA), 4.3 % (LMN-1,2-OH), and 32 % (LMN-8,9-OH) of the orally administered dose. GC-PCI-MS full-scan analyses revealed dihydroperillic acid (DHPA) as an additional LMN metabolite. DHPA was estimated to account for 5 % of the orally administered dose. The study revealed that human LMN metabolism proceeds fast and is characterised by oxidation mainly of the exo-cyclic double bond but also of the endo-cyclic double bond and of the methyl side chain. The study results may support the prediction of the metabolism of other terpenes or comparable chemical structures.

  15. HandTutor™ enhanced hand rehabilitation after stroke--a pilot study.

    Science.gov (United States)

    Carmeli, Eli; Peleg, Sara; Bartur, Gadi; Elbo, Enbal; Vatine, Jean-Jacques

    2011-12-01

    This study assessed the potential therapeutic benefi t of using HandTutor™ in combination with traditional rehabilitation in a post-stroke sub-acute population. The study compares an experimental group receiving traditional therapy combined with HandTutorTM treatment, against a control group receiving only traditional therapy. An assessor-blinded, randomized controlled pilot trial, was conducted in the Reuth rehabilitation unit in Israel. Thirty-one stroke patients in the sub-acute phase, were randomly assigned to one of the two groups (experimental or control) in sets of three. The experimental group (n = 16) underwent a hand rehabilitation programme using the HandTutorTM combined with traditional therapy. The control group (n = 15) received only traditional therapy. The treatment schedules for both groups were of similar duration and frequency. Improvements were evaluated using three indicators: 1) The Brunnström-Fugl-Meyer (FM) test, 2) the Box and Blocks (B&B) test and 3) improvement parameters as determined by the HandTutorTM software. Following 15 consecutive treatment sessions, a signifi cant improvement was observed within the experimental group (95% confi dence intervals) compared with the control group: B&B p = 0.015; FM p = 0.041, HandTutor™ performance accuracy on x axis and performance accuracy on y axis p stroke hand function rehabilitation.

  16. 99Tcm-N(NOEt2 Uptake Kinetics Difference among KMB17 Human Embryonic Lung Diploid Fibroblast and Different Human Lung Cancer Cells

    Directory of Open Access Journals (Sweden)

    Wei JIA

    2010-04-01

    Full Text Available Background and objective PET/CT imaging is expensive, so searching the tumor imaging agent for SPECT/CT is necessary. 99Tcm-N(NOEt2 [bis (N-ethoxy-N-ethyl dithiocarbamato nitrido99Tcm (V] can be uptaken by lung cancer cells and other cells alike. The aim of this study is to evaluate the distinctive value in lung tumor with 99Tcm-N(NOEt2, the difference in its uptake kinetics in human embryonic lung diploid fibroblasts KMB17 and several kinds of lung cancer cells lines. Methods Firstly, six different cell culture medium which contained YTMLC Gejiu human lung squamous carcinoma cell, SPC-A1 human lung adenocarcinoma cell, AGZY low metastatic human lung adenocarcinoma, 973 high metastatic human lung adenocarcinoma cell, GLC-82 Gejiu human lung adenocarcinoma cell, and KMB17 human embryonic lung diploid fibroblast, respectively with equal cell density of 1×106/mL and the same volume were prepared; secondly, the same radioactive dose of 99Tcm-N(NOEt2 was added into each sample and then 300 μL mixed sample was taken out respectively and cultured in 37 oC culture box; Finally, 5 min, 15 min, 30 min, 45 min, 60 min, 75 min, 90 min after cultivation, centrifuged each cultured sample and determined the intracellular radiocounts of each sample, calculated each cell sample’s uptake rate of 99Tcm-N(NOEt2 at different time. Results Statistical difference was found among six cell samples, and the uptake rate sequence from high to low is 973 and SPC-A1>YTMLC>GLC-82>AGZY>KMB17 respectively; furthermore, 30 min-45 min after culture, the uptake rate reached stability, and the 45 min uptake rate of each sample was higher than its 96.7% uptake peak. Conclusion Based on the results above mentioned, it is supposed that there are discriminative clinical value when using 99Tcm-N(NOEt2 as a tumor targeting imaging agent, and 30 min or so after injection may be the best imaging time in the early imaging stage.

  17. Multicompartmental analysis of the kinetics of monoclonal antibody in cancer patients

    International Nuclear Information System (INIS)

    Koizumi, K.; De Nardo, G.L.; De Nardo, S.J.; Peng, J.S.; Macey, D.J.; Hisada, K.; Tonami, N.

    1985-01-01

    Multicompartmental models were applied for analysis of kinetics of iodide labeled monoclonal antibody in cancer patients. About 14 compartments such as intravascular antibody pool, interstitial antibody pool, antibody processors, tumor antigen site, intravascular immune complex pool, intravascular iodide pool, and urine iodide pool were assumed. This model accounts for three molecular species, the antibody, and antibody complex, and free iodide or iodinated peptides. Patients were injected with I-123-Lym-1 IgG2a (anti B cell lymphoma antibody). After injection, blood and urine samples were sequentially collected. Plasma and urine were separated by HPLC into fractions of intact antibody, immune complex, and free iodide. This information was used for input data in the theoretical model. SAAM computer program was used to solve these compartmental models. Published linear rate constants for human serum albumin and human non-immune IgG were initially used. However, data calculated from the model differed from observed curves in several respects. The kinetics of mouse monoclonal antibody, a foreign protein in a patient, were significantly different from those reported for human IgG. When a nonlinear, saturable hepatic processor was incorporated in the model, calculated data fit the observed data better. This kinetic model provides a basis for calculating radiation doses for radioiodinated antibodies

  18. The Avocado Hand

    LENUS (Irish Health Repository)

    Rahmani, G

    2017-11-01

    Accidental self-inflicted knife injuries to digits are a common cause of tendon and nerve injury requiring hand surgery. There has been an apparent increase in avocado related hand injuries. Classically, the patients hold the avocado in their non-dominant hand while using a knife to cut\\/peel the fruit with their dominant hand. The mechanism of injury is usually a stabbing injury to the non-dominant hand as the knife slips past the stone, through the soft avocado fruit. Despite their apparent increased incidence, we could not find any cases in the literature which describe the “avocado hand”. We present a case of a 32-year-old woman who sustained a significant hand injury while preparing an avocado. She required exploration and repair of a digital nerve under regional anaesthesia and has since made a full recovery.

  19. Bimanual proprioception: are two hands better than one?

    NARCIS (Netherlands)

    Wong, J.D.; Wilson, E.T.; Kistemaker, D.A.; Gribble, P.L.

    2014-01-01

    Information about the position of an object that is held in both hands, such as a golf club or a tennis racquet, is transmitted to the human central nervous system from peripheral sensors in both left and right arms. How does the brain combine these two sources of information? Using a robot to move

  20. Determination of calcium in foot, hand and vertebrae of man by neutron activation

    International Nuclear Information System (INIS)

    Zajchik, V.E.; Kondrashev, A.E.; Dubrovin, A.P.; Korelo, A.M.; Morukov, B.V.; Orlov, O.I.

    1990-01-01

    Methods and devices for in vivo neutron activation determination of calcium content in human foot, hand and vertebrae were developed. It is ascertained that calcium content in skeleton is subjected to seasonal cyclicity. Bones of foot have the minimum content of the element in winter-spring period and the maximum one in summer-autumn period. For vertebrae and hand the inverse dependence is characteristic. Average level of seasonal variations in calcium content in the bones of hand and vertebrae is 10-11%, that of foot - 18-19%. Amplitudes of seasonal variations in the content of calcium in vertebrae, hand and foot are interrelated. 5 refs.; 1 tab

  1. Souk: Spatial Observation of hUman Kinetics

    OpenAIRE

    Killijian , Marc-Olivier; Pasqua , Roberto; Roy , Matthieu; Trédan , Gilles; Zanon , Christophe

    2016-01-01

    International audience; Simulating human-centered pervasive systems requires accurate assumptions on the behavior of human groups. Recent models consider this behavior as a combination of both social and spatial factors. Yet, establishing accurate traces of human groups is difficult: current techniques capture either positions, or contacts, with a limited accuracy. In this paper, we introduce a new technique to capture such behaviors. The interest of this approach lies in the unprecedented ac...

  2. SOUK: Social Observation of hUman Kinetics

    OpenAIRE

    Killijian , Marc-Olivier; Roy , Matthieu; Trédan , Gilles; Zanon , Christophe

    2013-01-01

    International audience; Simulating human-centered pervasive systems requires accurate assumptions on the behavior of human groups. Recent models consider this behavior as a combination of both social and spatial factors. Yet, establishing accurate traces of human groups is difficult: current techniques capture either positions, or contacts, with a limited accuracy. In this paper we introduce a new technique to capture such behaviors. The interest of this approach lies in the unprecedented acc...

  3. The association of hand preference and sensation seeking behavior.

    Science.gov (United States)

    Kuderer, Sonja; Kirchengast, Sylvia

    Although the human body shows a superficial symmetry, the disparate functions and skills of both body halves lead to an asymmetrical use. As a result, lateral preferences are detectable, which also include the favoured use of one hand ('handedness'). The collection of questionnaire data on sensation seeking and the conduction of behavioral handedness tasks by 55 research participants enabled the investigation of the interaction of handedness and sensation seeking. For this procedure the age-homogeneous study population is divided according to the Handedness-Index (HI) - a calculated value, indicating the practical hand preference. The results reveal a stronger lateralization in right-handed participants as well as a difference in the mean value of hand use in the three handedness groups. Sensation seeking behavior shows significant negative correlations with age as well as with the HI. Higher scores of left-handers in Experience Seeking (ES), Sensation Seeking (SS) as well as in Thrill and Adventure Seeking (TAS) indicate a larger risk investment in this handedness group. Hence, the results of this study suggest that handedness is a strong indicator of risk behavior.

  4. Analysis of National Institutes of Health Funding in Hand Surgery.

    Science.gov (United States)

    Silvestre, Jason; Ruan, Qing Z; Chang, Benjamin

    2018-01-01

    Federal research dollars help investigators develop biomedical therapies for human diseases. Currently, the state of funding in hand surgery is poorly understood. This study defines the portfolio of National Institutes of Health (NIH) grants awarded in hand surgery. This was a cross-sectional study of hand surgeons in the US. Faculty members of accredited hand surgery fellowships and/or members of the American Society for Surgery of the Hand were queried in the NIH RePORT database for awards obtained during 2005-2015. Of 2317 hand surgeons queried, only 18 obtained an NIH grant (0.8%). Thirty-eight unique grants were identified totaling $42 197 375. R01 awards comprised the majority of funding (78.0%) while K08 awards accounted for 1.1%. The K-to-R transition rate was zero. The National Institute of Arthritis and Musculoskeletal and Skin Disease supported the most funding (65.2%), followed by the National Institute of Neurological Disorders and Stroke (30.8%). There was no statistically significant difference in NIH funding totals with hand surgeon characteristics. Funding supported translational (46.0%), basic science (29.6%), clinical (21.0%), and education-based (3.4%) research. Peripheral nerve (33.3%) and bone and joint disease (30.1%) received the most research funding. Less than 1% of hand surgeons obtain NIH research grants. Of the 2 identified K08 awards, none led to a subsequent R award. Future research should identify barriers to grant procurement to design effective policies to increase NIH funding in hand surgery.

  5. Brain Regions Associated to a Kinesthetic Illusion Evoked by Watching a Video of One's Own Moving Hand.

    Science.gov (United States)

    Kaneko, Fuminari; Blanchard, Caroline; Lebar, Nicolas; Nazarian, Bruno; Kavounoudias, Anne; Romaiguère, Patricia

    2015-01-01

    It is well known that kinesthetic illusions can be induced by stimulation of several sensory systems (proprioception, touch, vision…). In this study we investigated the cerebral network underlying a kinesthetic illusion induced by visual stimulation by using functional magnetic resonance imaging (fMRI) in humans. Participants were instructed to keep their hand still while watching the video of their own moving hand (Self Hand) or that of someone else's moving hand (Other Hand). In the Self Hand condition they experienced an illusory sensation that their hand was moving whereas the Other Hand condition did not induce any kinesthetic illusion. The contrast between the Self Hand and Other Hand conditions showed significant activation in the left dorsal and ventral premotor cortices, in the left Superior and Inferior Parietal lobules, at the right Occipito-Temporal junction as well as in bilateral Insula and Putamen. Most strikingly, there was no activation in the primary motor and somatosensory cortices, whilst previous studies have reported significant activation in these regions for vibration-induced kinesthetic illusions. To our knowledge, this is the first study that indicates that humans can experience kinesthetic perception without activation in the primary motor and somatosensory areas. We conclude that under some conditions watching a video of one's own moving hand could lead to activation of a network that is usually involved in processing copies of efference, thus leading to the illusory perception that the real hand is indeed moving.

  6. Brain Regions Associated to a Kinesthetic Illusion Evoked by Watching a Video of One's Own Moving Hand.

    Directory of Open Access Journals (Sweden)

    Fuminari Kaneko

    Full Text Available It is well known that kinesthetic illusions can be induced by stimulation of several sensory systems (proprioception, touch, vision…. In this study we investigated the cerebral network underlying a kinesthetic illusion induced by visual stimulation by using functional magnetic resonance imaging (fMRI in humans. Participants were instructed to keep their hand still while watching the video of their own moving hand (Self Hand or that of someone else's moving hand (Other Hand. In the Self Hand condition they experienced an illusory sensation that their hand was moving whereas the Other Hand condition did not induce any kinesthetic illusion. The contrast between the Self Hand and Other Hand conditions showed significant activation in the left dorsal and ventral premotor cortices, in the left Superior and Inferior Parietal lobules, at the right Occipito-Temporal junction as well as in bilateral Insula and Putamen. Most strikingly, there was no activation in the primary motor and somatosensory cortices, whilst previous studies have reported significant activation in these regions for vibration-induced kinesthetic illusions. To our knowledge, this is the first study that indicates that humans can experience kinesthetic perception without activation in the primary motor and somatosensory areas. We conclude that under some conditions watching a video of one's own moving hand could lead to activation of a network that is usually involved in processing copies of efference, thus leading to the illusory perception that the real hand is indeed moving.

  7. Preference for orientations commonly viewed for one's own hand in the anterior intraparietal cortex.

    Directory of Open Access Journals (Sweden)

    Regine Zopf

    Full Text Available Brain regions in the intraparietal and the premotor cortices selectively process visual and multisensory events near the hands (peri-hand space. Visual information from the hand itself modulates this processing potentially because it is used to estimate the location of one's own body and the surrounding space. In humans specific occipitotemporal areas process visual information of specific body parts such as hands. Here we used an fMRI block-design to investigate if anterior intraparietal and ventral premotor 'peri-hand areas' exhibit selective responses to viewing images of hands and viewing specific hand orientations. Furthermore, we investigated if the occipitotemporal 'hand area' is sensitive to viewed hand orientation. Our findings demonstrate increased BOLD responses in the left anterior intraparietal area when participants viewed hands and feet as compared to faces and objects. Anterior intraparietal and also occipitotemporal areas in the left hemisphere exhibited response preferences for viewing right hands with orientations commonly viewed for one's own hand as compared to uncommon own hand orientations. Our results indicate that both anterior intraparietal and occipitotemporal areas encode visual limb-specific shape and orientation information.

  8. Ability of Hand Hygiene Interventions Using Alcohol-Based Hand Sanitizers and Soap To Reduce Microbial Load on Farmworker Hands Soiled during Harvest.

    Science.gov (United States)

    de Aceituno, Anna Fabiszewski; Bartz, Faith E; Hodge, Domonique Watson; Shumaker, David J; Grubb, James E; Arbogast, James W; Dávila-Aviña, Jorgé; Venegas, Fabiola; Heredia, Norma; García, Santos; Leon, Juan S

    2015-11-01

    Effective hand hygiene is essential to prevent the spread of pathogens on produce farms and reduce foodborne illness. The U.S. Food and Drug Administration Food Safety Modernization Act Proposed Rule for Produce Safety recommends the use of soap and running water for hand hygiene of produce handlers. The use of alcohol-based hand sanitizer (ABHS) may be an effective alternative hygiene intervention where access to water is limited. There are no published data on the efficacy of either soap or ABHS-based interventions to reduce microbial contamination in agricultural settings. The goal of this study was to assess the ability of two soap-based (traditional or pumice) and two ABHS-based (label-use or two-step) hygiene interventions to reduce microbes (coliforms, Escherichia coli, and Enterococcus spp.) and soil (absorbance of hand rinsate at 600 nm [A600]) on farmworker hands after harvesting produce, compared with the results for a no-hand-hygiene control. With no hand hygiene, farmworker hands were soiled (median A600, 0.48) and had high concentrations of coliforms (geometric mean, 3.4 log CFU per hand) and Enterococcus spp. (geometric mean, 5.3 log CFU per hand) after 1 to 2 h of harvesting tomatoes. Differences in microbial loads in comparison to the loads in the control group varied by indicator organism and hygiene intervention (0 to 2.3 log CFU per hand). All interventions yielded lower concentrations of Enterococcus spp. and E. coli (P hands (P hand washing with soap at reducing indicator organisms on farmworker hands. Based on these results, ABHS is an efficacious hand hygiene solution for produce handlers, even on soiled hands.

  9. Hand based visual intent recognition algorithm for wheelchair motion

    CSIR Research Space (South Africa)

    Luhandjula, T

    2010-05-01

    Full Text Available This paper describes an algorithm for a visual human-machine interface that infers a person’s intention from the motion of the hand. Work in progress shows a proof of concept tested on static images. The context for which this solution is intended...

  10. Hand Therapy

    Science.gov (United States)

    ... from conditions such as carpal tunnel syndrome and tennis elbow , as well as from chronic problems such as ... Tools Advice from a Certified Hand Therapist on Tennis Elbow Advice from a Certified Hand Therapist: Living with( ...

  11. Stationary Hand Gesture Authentication Using Edit Distance on Finger Pointing Direction Interval

    Directory of Open Access Journals (Sweden)

    Alex Ming Hui Wong

    2016-01-01

    Full Text Available One of the latest authentication methods is by discerning human gestures. Previous research has shown that different people can develop distinct gesture behaviours even when executing the same gesture. Hand gesture is one of the most commonly used gestures in both communication and authentication research since it requires less room to perform as compared to other bodily gestures. There are different types of hand gesture and they have been researched by many researchers, but stationary hand gesture has yet to be thoroughly explored. There are a number of disadvantages and flaws in general hand gesture authentication such as reliability, usability, and computational cost. Although stationary hand gesture is not able to solve all these problems, it still provides more benefits and advantages over other hand gesture authentication methods, such as making gesture into a motion flow instead of trivial image capturing, and requires less room to perform, less vision cue needed during performance, and so forth. In this paper, we introduce stationary hand gesture authentication by implementing edit distance on finger pointing direction interval (ED-FPDI from hand gesture to model behaviour-based authentication system. The accuracy rate of the proposed ED-FPDI shows promising results.

  12. Defensive peripersonal space: the blink reflex evoked by hand stimulation is increased when the hand is near the face.

    Science.gov (United States)

    Sambo, C F; Liang, M; Cruccu, G; Iannetti, G D

    2012-02-01

    Electrical stimulation of the median nerve at the wrist may elicit a blink reflex [hand blink reflex (HBR)] mediated by a neural circuit at brain stem level. As, in a Sherringtonian sense, the blink reflex is a defensive response, in a series of experiments we tested, in healthy volunteers, whether and how the HBR is modulated by the proximity of the stimulated hand to the face. Electromyographic activity was recorded from the orbicularis oculi, bilaterally. We observed that the HBR is enhanced when the stimulated hand is inside the peripersonal space of the face, compared with when it is outside, irrespective of whether the proximity of the hand to the face is manipulated by changing the position of the arm (experiment 1) or by rotating the head while keeping the arm position constant (experiment 3). Experiment 2 showed that such HBR enhancement has similar magnitude when the participants have their eyes closed. Experiments 4 and 5 showed, respectively, that the blink reflex elicited by the electrical stimulation of the supraorbital nerve, as well as the N20 wave of the somatosensory evoked potentials elicited by the median nerve stimulation, are entirely unaffected by hand position. Taken together, our results provide compelling evidence that the brain stem circuits mediating the HBR in humans undergo tonic and selective top-down modulation from higher order cortical areas responsible for encoding the location of somatosensory stimuli in external space coordinates. These findings support the existence of a "defensive" peripersonal space, representing a safety margin advantageous for survival.

  13. Kinetics of the Dynamical Information Shannon Entropy for Complex Systems

    International Nuclear Information System (INIS)

    Yulmetyev, R.M.; Yulmetyeva, D.G.

    1999-01-01

    Kinetic behaviour of dynamical information Shannon entropy is discussed for complex systems: physical systems with non-Markovian property and memory in correlation approximation, and biological and physiological systems with sequences of the Markovian and non-Markovian random noises. For the stochastic processes, a description of the information entropy in terms of normalized time correlation functions is given. The influence and important role of two mutually dependent channels of the entropy change, correlation (creation or generation of correlations) and anti-correlation (decay or annihilation of correlation) is discussed. The method developed here is also used in analysis of the density fluctuations in liquid cesium obtained from slow neutron scattering data, fractal kinetics of the long-range fluctuation in the short-time human memory and chaotic dynamics of R-R intervals of human ECG. (author)

  14. Cesium removal and kinetics equilibrium: Precipitation kinetics

    International Nuclear Information System (INIS)

    Barnes, M.J.

    1999-01-01

    This task consisted of both non-radioactive and radioactive (tracer) tests examining the influence of potentially significant variables on cesium tetraphenylborate precipitation kinetics. The work investigated the time required to reach cesium decontamination and the conditions that affect the cesium precipitation kinetics

  15. Perfusion kinetics in human brain tumor with DCE-MRI derived model and CFD analysis.

    Science.gov (United States)

    Bhandari, A; Bansal, A; Singh, A; Sinha, N

    2017-07-05

    Cancer is one of the leading causes of death all over the world. Among the strategies that are used for cancer treatment, the effectiveness of chemotherapy is often hindered by factors such as irregular and non-uniform uptake of drugs inside tumor. Thus, accurate prediction of drug transport and deposition inside tumor is crucial for increasing the effectiveness of chemotherapeutic treatment. In this study, a computational model of human brain tumor is developed that incorporates dynamic contrast enhanced-magnetic resonance imaging (DCE-MRI) data into a voxelized porous media model. The model takes into account realistic transport and perfusion kinetics parameters together with realistic heterogeneous tumor vasculature and accurate arterial input function (AIF), which makes it patient specific. The computational results for interstitial fluid pressure (IFP), interstitial fluid velocity (IFV) and tracer concentration show good agreement with the experimental results. The computational model can be extended further for predicting the deposition of chemotherapeutic drugs in tumor environment as well as selection of the best chemotherapeutic drug for a specific patient. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Hand hygiene--evaluation of three disinfectant hand sanitizers in a community setting.

    Directory of Open Access Journals (Sweden)

    Rita Babeluk

    Full Text Available Hand hygiene is acknowledged as the single most important measure to prevent nosocomial infections in the healthcare setting. Similarly, in non-clinical settings, hand hygiene is recognised as a key element in helping prevent the spread of infectious diseases. The aim of this study was to evaluate the efficacy of three different disinfectant hand sanitizers in reducing the burden of bacterial hand contamination in 60 healthy volunteers in a community setting, both before and after education about the correct use of hand sanitizers. The study is the first to evaluate the efficacy and ease of use of different formulations of hand rubs used by the general population. The products tested were: Sterillium (perfumed, liquid, desderman pure gel (odorless, gel and Lavit (perfumed, spray. Sterillium and desderman are EN1500 (hygienic hand rub certified products (available in pharmacy and Lavit is non EN1500 certified and available in supermarkets. The two EN1500 certified products were found to be significantly superior in terms of reducing bacterial load. desderman pure gel, Sterillium and Lavit reduced the bacterial count to 6.4%, 8.2% and 28.0% respectively. After education in the correct use of each hand rub, the bacterial load was reduced even further, demonstrating the value of education in improving hand hygiene. Information about the testers' perceptions of the three sanitizers, together with their expectations of a hand sanitizer was obtained through a questionnaire. Efficacy, followed by skin compatibility were found to be the two most important attributes of a hand disinfectant in our target group.

  17. Postural Hand Synergies during Environmental Constraint Exploitation

    Directory of Open Access Journals (Sweden)

    Cosimo Della Santina

    2017-08-01

    Full Text Available Humans are able to intuitively exploit the shape of an object and environmental constraints to achieve stable grasps and perform dexterous manipulations. In doing that, a vast range of kinematic strategies can be observed. However, in this work we formulate the hypothesis that such ability can be described in terms of a synergistic behavior in the generation of hand postures, i.e., using a reduced set of commonly used kinematic patterns. This is in analogy with previous studies showing the presence of such behavior in different tasks, such as grasping. We investigated this hypothesis in experiments performed by six subjects, who were asked to grasp objects from a flat surface. We quantitatively characterized hand posture behavior from a kinematic perspective, i.e., the hand joint angles, in both pre-shaping and during the interaction with the environment. To determine the role of tactile feedback, we repeated the same experiments but with subjects wearing a rigid shell on the fingertips to reduce cutaneous afferent inputs. Results show the persistence of at least two postural synergies in all the considered experimental conditions and phases. Tactile impairment does not alter significantly the first two synergies, and contact with the environment generates a change only for higher order Principal Components. A good match also arises between the first synergy found in our analysis and the first synergy of grasping as quantified by previous work. The present study is motivated by the interest of learning from the human example, extracting lessons that can be applied in robot design and control. Thus, we conclude with a discussion on implications for robotics of our findings.

  18. A Methodology for the Design of Robotic Hands with Multiple Fingers

    Directory of Open Access Journals (Sweden)

    Jorge Eduardo Parada Puig

    2008-11-01

    Full Text Available This paper presents a methodology that has been applied for a design process of anthropomorphic hands with multiple fingers. Biomechanical characteristics of human hand have been analysed so that ergonomic and anthropometric aspects have been used as fundamental references for obtaining grasping mechanisms. A kinematic analysis has been proposed to define the requirements for designing grasping functions. Selection of materials and actuators has been discussed too. This topic has been based on previous experiences with prototypes that have been developed at the Laboratory of Robotics and Mechatronics (LARM of the University of Cassino. An example of the application of the proposed method has been presented for the design of a first prototype of LARM Hand.

  19. Kinetics of Intracellular, Extracellular and Production of Pro ...

    African Journals Online (AJOL)

    Keywords: Pro-inflammatory cytokine, Tumor necrosis factor-α, Interleukin-1α, Interleukin-1β,. Interleukin-6, Interleukin-8. Tropical Journal of ... retains neutrophils at sites of inflammation [6]. Many studies on the kinetics of cytokine ..... Lijnen P, Saavedra A, Petrov P. In vitro proliferative response of human peripheral blood ...

  20. Kinetic compartmental analysis of carnitine metabolism in the dog

    International Nuclear Information System (INIS)

    Rebouche, C.J.; Engel, A.G.

    1983-01-01

    This study was undertaken to quantitate the dynamic parameters of carnitine metabolism in the dog. Six mongrel dogs were given intravenous injections of L-[methyl-3H]carnitine and the specific radioactivity of carnitine was followed in plasma and urine for 19-28 days. The data were analyzed by kinetic compartmental analysis. A three-compartment, open-system model [(a) extracellular fluid, (b) cardiac and skeletal muscle, (c) other tissues, particularly liver and kidney] was adopted and kinetic parameters (carnitine flux, pool sizes, kinetic constants) were derived. In four of six dogs the size of the muscle carnitine pool obtained by kinetic compartmental analysis agreed (+/- 5%) with estimates based on measurement of carnitine concentrations in different muscles. In three of six dogs carnitine excretion rates derived from kinetic compartmental analysis agreed (+/- 9%) with experimentally measured values, but in three dogs the rates by kinetic compartmental analysis were significantly higher than the corresponding rates measured directly. Appropriate chromatographic analyses revealed no radioactive metabolites in muscle or urine of any of the dogs. Turnover times for carnitine were (mean +/- SEM): 0.44 +/- 0.05 h for extracellular fluid, 232 +/- 22 h for muscle, and 7.9 +/- 1.1 h for other tissues. The estimated flux of carnitine in muscle was 210 pmol/min/g of tissue. Whole-body turnover time for carnitine was 62.9 +/- 5.6 days (mean +/- SEM). Estimated carnitine biosynthesis ranged from 2.9 to 28 mumol/kg body wt/day. Results of this study indicate that kinetic compartmental analysis may be applicable to study of human carnitine metabolism

  1. 3D pose estimation and motion analysis of the articulated human hand-forearm limb in an industrial production environment

    Science.gov (United States)

    Hahn, Markus; Barrois, Björn; Krüger, Lars; Wöhler, Christian; Sagerer, Gerhard; Kummert, Franz

    2010-09-01

    This study introduces an approach to model-based 3D pose estimation and instantaneous motion analysis of the human hand-forearm limb in the application context of safe human-robot interaction. 3D pose estimation is performed using two approaches: The Multiocular Contracting Curve Density (MOCCD) algorithm is a top-down technique based on pixel statistics around a contour model projected into the images from several cameras. The Iterative Closest Point (ICP) algorithm is a bottom-up approach which uses a motion-attributed 3D point cloud to estimate the object pose. Due to their orthogonal properties, a fusion of these algorithms is shown to be favorable. The fusion is performed by a weighted combination of the extracted pose parameters in an iterative manner. The analysis of object motion is based on the pose estimation result and the motion-attributed 3D points belonging to the hand-forearm limb using an extended constraint-line approach which does not rely on any temporal filtering. A further refinement is obtained using the Shape Flow algorithm, a temporal extension of the MOCCD approach, which estimates the temporal pose derivative based on the current and the two preceding images, corresponding to temporal filtering with a short response time of two or at most three frames. Combining the results of the two motion estimation stages provides information about the instantaneous motion properties of the object. Experimental investigations are performed on real-world image sequences displaying several test persons performing different working actions typically occurring in an industrial production scenario. In all example scenes, the background is cluttered, and the test persons wear various kinds of clothes. For evaluation, independently obtained ground truth data are used. [Figure not available: see fulltext.

  2. Determination of Model Kinetics for Forced Unsteady State Operation of Catalytic CH4 Oxidation

    Directory of Open Access Journals (Sweden)

    Effendy Mohammad

    2016-01-01

    . On the other hand, the kinetic rate expression obtained in the unsteady state operation fitted quite well. It was proven that in one cycle period the kinetic rate would always shift according to the ratio of CH4/O2.

  3. Finger impedance evaluation by means of hand exoskeleton.

    Science.gov (United States)

    Fiorilla, Angelo Emanuele; Nori, Francesco; Masia, Lorenzo; Sandini, Giulio

    2011-12-01

    Modulation of arm mechanical impedance is a fundamental aspect for interaction with the external environment and its regulation is essential for stability preservation during manipulation. Even though past research on human arm movements has suggested that models of human finger impedance would benefit the study of neural control mechanisms and the design of novel hand prostheses, relatively few studies have focused on finger and hand impedance. This article touches on the two main aspects of this research topic: first it introduces a mechanical refinement of a device that can be used to effectively measure finger impedance during manipulation tasks; then, it describes a pilot study aimed at identifying the inertia of the finger and the viscous and elastic properties of finger muscles. The proposed wearable exoskeleton, which has been designed to measure finger posture and impedance modulation while leaving the palm free, is capable of applying fast displacements while monitoring the interaction forces between the human finger and the robotic links. Moreover, due to the relatively small inertia of the fingers, it allows us to meet some stringent specifications, performing relatively large displacements (~45°) before the stretch reflex intervenes (~25 ms). The results of measurements on five subjects show that inertia, damping, and stiffness can be effectively identified and that the parameters obtained are comparable with values from previous studies.

  4. A Cell Kinetic Model of Granulocytopoiesis Under Radiation Exposure: Extension from Murines to Canines and Humans

    Science.gov (United States)

    Hu, Shaowen; Cucinotta, Francis A.

    2009-01-01

    Space radiation poses significant challenges to space travel, and it is essential to understand the possible adverse effects from space radiation exposure to the radiosensitive organ systems that are important for immediate survival of human, e.g., the hematopoietic system. In this presentation a biomathematical model of granulocytopoiesis is described and used to analyze the blood granulocyte changes seen in the blood of mammalians under continuous and acute radiation exposure. This is one of a set of hematopoietic models that have been successfully utilized to simulate and interpret the experimental data of acute and chronic radiation on rodents. We discuss the underlying implicit regulation mechanism and the biological relevance of the kinetic parameters estimation method. Extension of the model to predictions in dogs and humans systems indicates that the modeling results are consistent with the cumulative experimental and empirical data from various sources. This implies the potential to integrate the models into one united system for monitoring the hematopoietic response of various species under irradiation. Based on the evidence of threshold responses of dogs to extended periods of low daily dose exposures, we discuss the potential health risks of the space traveler under chronic stress of low-dose irradiation and the possibly encountered Solar Particle Events.

  5. About Hand Surgery

    Science.gov (United States)

    ... Find a hand surgeon near you. © 2009 American Society for Surgery of the Hand. Definition developed by ASSH Council. Other Links CME Mission Statement and Disclaimer Policies and Technical Requirements Exhibits and Partners ASSH 822 W. Washington Blvd. ... 2018 by American Society for Surgery of the Hand × Search Tips Tip ...

  6. Perfection of technical and tactical preparation of sportsmen of hand-to-hand fight

    Directory of Open Access Journals (Sweden)

    Serebryak V.V.

    2010-06-01

    Full Text Available Essence of innovative hike is considered to upgrading preparation of sportsmen of hand-to-hand fight. 58 sportsmen of section of hand-to-hand fight took part in research. Age of sportsmen are from 17 to 22 years. Developed and approved the most effective technical and tactical charts of construction of duel with the opponents of different styles of single combats. It is well-proven that offered approach instrumental in development of operative thought and adaptation to sparring of hand-to-hand fight.

  7. Osteoarthritis of the Hand

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Osteoarthritis Email to a friend * required fields From * ...

  8. Human-Manipulator Interface Using Particle Filter

    Directory of Open Access Journals (Sweden)

    Guanglong Du

    2014-01-01

    Full Text Available This paper utilizes a human-robot interface system which incorporates particle filter (PF and adaptive multispace transformation (AMT to track the pose of the human hand for controlling the robot manipulator. This system employs a 3D camera (Kinect to determine the orientation and the translation of the human hand. We use Camshift algorithm to track the hand. PF is used to estimate the translation of the human hand. Although a PF is used for estimating the translation, the translation error increases in a short period of time when the sensors fail to detect the hand motion. Therefore, a methodology to correct the translation error is required. What is more, to be subject to the perceptive limitations and the motor limitations, human operator is hard to carry out the high precision operation. This paper proposes an adaptive multispace transformation (AMT method to assist the operator to improve the accuracy and reliability in determining the pose of the robot. The human-robot interface system was experimentally tested in a lab environment, and the results indicate that such a system can successfully control a robot manipulator.

  9. Flow chemistry and polymer-supported pseudoenantiomeric acylating agents enable parallel kinetic resolution of chiral saturated N-heterocycles

    Science.gov (United States)

    Kreituss, Imants; Bode, Jeffrey W.

    2017-05-01

    Kinetic resolution is a common method to obtain enantioenriched material from a racemic mixture. This process will deliver enantiopure unreacted material when the selectivity factor of the process, s, is greater than 1; however, the scalemic reaction product is often discarded. Parallel kinetic resolution, on the other hand, provides access to two enantioenriched products from a single racemic starting material, but suffers from a variety of practical challenges regarding experimental design that limit its applications. Here, we describe the development of a flow-based system that enables practical parallel kinetic resolution of saturated N-heterocycles. This process provides access to both enantiomers of the starting material in good yield and high enantiopurity; similar results with classical kinetic resolution would require selectivity factors in the range of s = 100. To achieve this, two immobilized quasienantiomeric acylating agents were designed for the asymmetric acylation of racemic saturated N-heterocycles. Using the flow-based system we could efficiently separate, recover and reuse the polymer-supported reagents. The amide products could be readily separated and hydrolysed to the corresponding amines without detectable epimerization.

  10. Effectiveness of liquid soap and hand sanitizer against Norwalk virus on contaminated hands.

    Science.gov (United States)

    Liu, Pengbo; Yuen, Yvonne; Hsiao, Hui-Mien; Jaykus, Lee-Ann; Moe, Christine

    2010-01-01

    Disinfection is an essential measure for interrupting human norovirus (HuNoV) transmission, but it is difficult to evaluate the efficacy of disinfectants due to the absence of a practicable cell culture system for these viruses. The purpose of this study was to screen sodium hypochlorite and ethanol for efficacy against Norwalk virus (NV) and expand the studies to evaluate the efficacy of antibacterial liquid soap and alcohol-based hand sanitizer for the inactivation of NV on human finger pads. Samples were tested by real-time reverse transcription-quantitative PCR (RT-qPCR) both with and without a prior RNase treatment. In suspension assay, sodium hypochlorite concentrations of >or=160 ppm effectively eliminated RT-qPCR detection signal, while ethanol, regardless of concentration, was relatively ineffective, giving at most a 0.5 log(10) reduction in genomic copies of NV cDNA. Using the American Society for Testing and Materials (ASTM) standard finger pad method and a modification thereof (with rubbing), we observed the greatest reduction in genomic copies of NV cDNA with the antibacterial liquid soap treatment (0.67 to 1.20 log(10) reduction) and water rinse only (0.58 to 1.58 log(10) reduction). The alcohol-based hand sanitizer was relatively ineffective, reducing the genomic copies of NV cDNA by only 0.14 to 0.34 log(10) compared to baseline. Although the concentrations of genomic copies of NV cDNA were consistently lower on finger pad eluates pretreated with RNase compared to those without prior RNase treatment, these differences were not statistically significant. Despite the promise of alcohol-based sanitizers for the control of pathogen transmission, they may be relatively ineffective against the HuNoV, reinforcing the need to develop and evaluate new products against this important group of viruses.

  11. Tracking and Classification of In-Air Hand Gesture Based on Thermal Guided Joint Filter.

    Science.gov (United States)

    Kim, Seongwan; Ban, Yuseok; Lee, Sangyoun

    2017-01-17

    The research on hand gestures has attracted many image processing-related studies, as it intuitively conveys the intention of a human as it pertains to motional meaning. Various sensors have been used to exploit the advantages of different modalities for the extraction of important information conveyed by the hand gesture of a user. Although many works have focused on learning the benefits of thermal information from thermal cameras, most have focused on face recognition or human body detection, rather than hand gesture recognition. Additionally, the majority of the works that take advantage of multiple modalities (e.g., the combination of a thermal sensor and a visual sensor), usually adopting simple fusion approaches between the two modalities. As both thermal sensors and visual sensors have their own shortcomings and strengths, we propose a novel joint filter-based hand gesture recognition method to simultaneously exploit the strengths and compensate the shortcomings of each. Our study is motivated by the investigation of the mutual supplementation between thermal and visual information in low feature level for the consistent representation of a hand in the presence of varying lighting conditions. Accordingly, our proposed method leverages the thermal sensor's stability against luminance and the visual sensors textural detail, while complementing the low resolution and halo effect of thermal sensors and the weakness against illumination of visual sensors. A conventional region tracking method and a deep convolutional neural network have been leveraged to track the trajectory of a hand gesture and to recognize the hand gesture, respectively. Our experimental results show stability in recognizing a hand gesture against varying lighting conditions based on the contribution of the joint kernels of spatial adjacency and thermal range similarity.

  12. Quantitative fluorescence kinetic analysis of NADH and FAD in human plasma using three- and four-way calibration methods capable of providing the second-order advantage

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chao [School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550025 (China); Wu, Hai-Long, E-mail: hlwu@hnu.edu.cn [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Zhou, Chang; Xiang, Shou-Xia; Zhang, Xiao-Hua; Yu, Yong-Jie; Yu, Ru-Qin [State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China)

    2016-03-03

    The metabolic coenzymes reduced nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) are the primary electron donor and acceptor respectively, participate in almost all biological metabolic pathways. This study develops a novel method for the quantitative kinetic analysis of the degradation reaction of NADH and the formation reaction of FAD in human plasma containing an uncalibrated interferent, by using three-way calibration based on multi-way fluorescence technique. In the three-way analysis, by using the calibration set in a static manner, we directly predicted the concentrations of both analytes in the mixture at any time after the start of their reactions, even in the presence of an uncalibrated spectral interferent and a varying background interferent. The satisfactory quantitative results indicate that the proposed method allows one to directly monitor the concentration of each analyte in the mixture as the function of time in real-time and nondestructively, instead of determining the concentration after the analytical separation. Thereafter, we fitted the first-order rate law to their concentration data throughout their reactions. Additionally, a four-way calibration procedure is developed as an alternative for highly collinear systems. The results of the four-way analysis confirmed the results of the three-way analysis and revealed that both the degradation reaction of NADH and the formation reaction of FAD in human plasma fit the first-order rate law. The proposed methods could be expected to provide promising tools for simultaneous kinetic analysis of multiple reactions in complex systems in real-time and nondestructively. - Highlights: • A novel three-way calibration method for the quantitative kinetic analysis of NADH and FAD in human plasma is proposed. • The method can directly monitor the concentration of each analyte in the reaction in real-time and nondestructively. • The method has the second-order advantage. • A

  13. Quantitative fluorescence kinetic analysis of NADH and FAD in human plasma using three- and four-way calibration methods capable of providing the second-order advantage

    International Nuclear Information System (INIS)

    Kang, Chao; Wu, Hai-Long; Zhou, Chang; Xiang, Shou-Xia; Zhang, Xiao-Hua; Yu, Yong-Jie; Yu, Ru-Qin

    2016-01-01

    The metabolic coenzymes reduced nicotinamide adenine dinucleotide (NADH) and flavin adenine dinucleotide (FAD) are the primary electron donor and acceptor respectively, participate in almost all biological metabolic pathways. This study develops a novel method for the quantitative kinetic analysis of the degradation reaction of NADH and the formation reaction of FAD in human plasma containing an uncalibrated interferent, by using three-way calibration based on multi-way fluorescence technique. In the three-way analysis, by using the calibration set in a static manner, we directly predicted the concentrations of both analytes in the mixture at any time after the start of their reactions, even in the presence of an uncalibrated spectral interferent and a varying background interferent. The satisfactory quantitative results indicate that the proposed method allows one to directly monitor the concentration of each analyte in the mixture as the function of time in real-time and nondestructively, instead of determining the concentration after the analytical separation. Thereafter, we fitted the first-order rate law to their concentration data throughout their reactions. Additionally, a four-way calibration procedure is developed as an alternative for highly collinear systems. The results of the four-way analysis confirmed the results of the three-way analysis and revealed that both the degradation reaction of NADH and the formation reaction of FAD in human plasma fit the first-order rate law. The proposed methods could be expected to provide promising tools for simultaneous kinetic analysis of multiple reactions in complex systems in real-time and nondestructively. - Highlights: • A novel three-way calibration method for the quantitative kinetic analysis of NADH and FAD in human plasma is proposed. • The method can directly monitor the concentration of each analyte in the reaction in real-time and nondestructively. • The method has the second-order advantage. • A

  14. Hand eczema

    DEFF Research Database (Denmark)

    Ibler, K.S.; Jemec, G.B.E.; Flyvholm, M.-A.

    2012-01-01

    Background. Healthcare workers are at increased risk of developing hand eczema. Objectives. To investigate the prevalence and severity of self-reported hand eczema, and to relate the findings to demographic data, occupation, medical speciality, wards, shifts, and working hours. Patients/materials......Background. Healthcare workers are at increased risk of developing hand eczema. Objectives. To investigate the prevalence and severity of self-reported hand eczema, and to relate the findings to demographic data, occupation, medical speciality, wards, shifts, and working hours. Patients...... dermatitis, younger age, male sex (male doctors), and working hours. Eighty nine per cent of subjects reported mild/moderate lesions. Atopic dermatitis was the only factor significantly related to severity. Sick leave was reported by 8% of subjects, and notification to the authorities by 12%. Conclusions...... or severity, but cultural differences between professions with respect to coping with the eczema were significant. Atopic dermatitis was related to increased prevalence and severity, and preventive efforts should be made for healthcare workers with atopic dermatitis....

  15. Development of a humanoid robot hand with coupling four-bar linkage

    Directory of Open Access Journals (Sweden)

    Xinhua Liu

    2017-01-01

    Full Text Available To improve the operating performance of robots’ end-effector, a humanoid robot hand based on coupling four-bar linkage was designed. An improved transmission system was proposed for the base joint of the thumb. Thus, a far greater motion range and more reasonable layout of the palm were obtained. Moreover, the mathematical model for kinematics simulation was presented based on the Assur linkage group theory to verify and optimize the proposed structure. To research the motion relationships between the fingers and the object in the process of grasping object, the grasping analysis of multi-finger manipulation was presented based on contact kinematics. Finally, a prototype of the humanoid robot hand was produced by a three-dimensional printer, and a kinematics simulation example and the workspace solving of the humanoid robot hand were carried out. The results showed that the velocities of finger joints approximately met the proportion relationship 1:1:1, which accorded with the grasping law of the human hand. In addition, the large workspace, reasonable layout, and good manipulability of the humanoid robot hand were verified.

  16. Influence of exercise intensity on skeletal muscle blood flow, O2 extraction and O2 uptake on-kinetics

    DEFF Research Database (Denmark)

    Jones, Andrew M; Krustrup, Peter; Wilkerson, Daryl P

    2012-01-01

    Key points Following the start of low-intensity exercise in healthy humans, it has been established that the kinetics of muscle O(2) delivery is faster than, and does not limit, the kinetics of muscle O(2) uptake. Direct data are lacking, however, on the question of whether O(2) delivery might...... limit O(2) uptake kinetics during high-intensity exercise. In this study, we made frequent measurements of muscle blood flow, arterial-to-venous O(2) difference (a- difference) and O(2) uptake following the onset of multiple transitions of both low-intensity and high-intensity knee-extension exercise...... in the same subjects. We show that although blood flow kinetics is slower for high-intensity compared with low-intensity exercise, this does not result in slower O(2) uptake kinetics. These results indicate that muscle O(2) delivery does not limit O(2) uptake during knee-extension exercise in healthy humans....

  17. Use of smartphones and portable media devices for quantifying human movement characteristics of gait, tendon reflex response, and Parkinson's disease hand tremor.

    Science.gov (United States)

    LeMoyne, Robert; Mastroianni, Timothy

    2015-01-01

    Smartphones and portable media devices are both equipped with sensor components, such as accelerometers. A software application enables these devices to function as a robust wireless accelerometer platform. The recorded accelerometer waveform can be transmitted wireless as an e-mail attachment through connectivity to the Internet. The implication of such devices as a wireless accelerometer platform is the experimental and post-processing locations can be placed anywhere in the world. Gait was quantified by mounting a smartphone or portable media device proximal to the lateral malleolus of the ankle joint. Attributes of the gait cycle were quantified with a considerable accuracy and reliability. The patellar tendon reflex response was quantified by using the device in tandem with a potential energy impact pendulum to evoke the patellar tendon reflex. The acceleration waveform maximum acceleration feature of the reflex response displayed considerable accuracy and reliability. By mounting the smartphone or portable media device to the dorsum of the hand through a glove, Parkinson's disease hand tremor was quantified and contrasted with significance to a non-Parkinson's disease steady hand control. With the methods advocated in this chapter, any aspect of human movement may be quantified through smartphones or portable media devices and post-processed anywhere in the world. These wearable devices are anticipated to substantially impact the biomedical and healthcare industry.

  18. The prevalence of the extensor digiti minimi tendon of the hand and its variants in humans: a systematic review and meta-analysis.

    Science.gov (United States)

    Yammine, Kaissar

    2015-01-01

    The extensor digiti minimi (EDM) is frequently used in the case of an abduction deformity of the little finger. It is also considered as a main resource for tendon transfer. However, it shows many variations in the human hand, which include splitting into two or more slips and sending a slip to the fourth finger, named the extensor digiti minimi et quarti (EDMQ). The aim of this systematic review is to perform an evidence synthesis on the prevalence of the EDM and its variants. Twenty-six cadaveric studies met the inclusion criteria with a total of 2247 hands. Meta-analysis results yielded an overall pooled prevalence estimate (PPE) of the EDM of 99.7% and PPEs of 11.5, 77.6, 7 and 0.6% for the single-, double-, triple- and quadruple-slip EDM, respectively. For the single-slip EDM, the frequencies were such that Indians > Middle Eastern > Europeans > Japanese > North Americans. For the double-slip EDM, the frequencies were such that Japanese > North Americans = Europeans > Middle Eastern > Indians. No significance was found with regard to hand side. The true EDMQ prevalence was found to be at 7.3%, whereas its crude prevalence was 8%. This artilce offers reference values on the prevalence of the EDM and its variants, which are thought to be highly relevant to both anatomists and clinicians.

  19. Manual activity shapes structure and function in contralateral human motor hand area

    DEFF Research Database (Denmark)

    Granert, Oliver; Peller, Martin; Gaser, Christian

    2011-01-01

    which was designed to improve handwriting-associated dystonia. Initially the dystonic hand was immobilized for 4 weeks with the intention to reverse faulty plasticity. After immobilization, patients accomplished a motor re-training for 8 weeks. T1-weighted MRIs of the whole brain and single-pulse TMS...

  20. The Effect of Antibacterial Formula Hand Cleaners on the Elimination of Microbes on Hands

    Science.gov (United States)

    Coleman, J. R.

    2002-05-01

    : The purpose of this project is to find out which one of the antibacterial hand cleanser (antibacterial bar soap, antibacterial liquid hand soap, and liquid hand sanitizer) is more effective in eliminating microbes. If antibacterial- formula liquid hand soap is used on soiled hands, then it will be more effective in eliminating microbes. Germs are microorganisms that cause disease and can spread from person-to-person. Bacteria are a kind of microbe, an example of which is Transient Flora that is often found on hands. Hand washing prevents germs from spreading to others. During the procedure, swabs were used to take samples before and after the soiled hands had been washed with one of the antibacterial hand cleansers. Nutrient Easygel was poured into petri dishes to harden for 1 day, and then samples were swabbed on the gel. The Petri dishes were placed in an incubator for 24 hours, and then data was recorded accordingly. The antibacterial liquid hand soap was sufficient in eliminating the majority of bacteria. The hands had 65% of the bacteria on them, and after the liquid hand soap was used only 37% of the bacteria remained.

  1. Determination of urea kinetics by isotope dilution with [C-13]urea and gas chromatography isotope ratio mass spectrometry (GC-IRMS) analysis

    NARCIS (Netherlands)

    Kloppenburg, Wybe; Wolthers, BG; Stellaard, F; Elzinga, H; Tepper, T; deJong, PE; Huisman, RM

    1. Stable urea isotopes can be used to study urea kinetics in humans, The use of stable urea isotopes far studying urea kinetic parameters in humans on a large scale is hampered by the high costs of the labelled material, We devised a urea dilution for measurement of the distribution volume,

  2. Movement coordination in applied human-human and human-robot interaction

    DEFF Research Database (Denmark)

    Schubö, Anna; Vesper, Cordula; Wiesbeck, Mathey

    2007-01-01

    and describing human-human interaction in terms of goal-oriented movement coordination is considered an important and necessary step for designing and describing human-robot interaction. In the present scenario, trajectories of hand and finger movements were recorded while two human participants performed......The present paper describes a scenario for examining mechanisms of movement coordination in humans and robots. It is assumed that coordination can best be achieved when behavioral rules that shape movement execution in humans are also considered for human-robot interaction. Investigating...... coordination were affected. Implications for human-robot interaction are discussed....

  3. A Three-Dimensional Kinematic and Kinetic Study of the College-Level Female Softball Swing

    Directory of Open Access Journals (Sweden)

    Monica Milanovich, Steven M. Nesbit

    2014-03-01

    Full Text Available This paper quantifies and discusses the three-dimensional kinematic and kinetic characteristics of the female softball swing as performed by fourteen female collegiate amateur subjects. The analyses were performed using a three-dimensional computer model. The model was driven kinematically from subject swings data that were recorded with a multi-camera motion analysis system. Each subject used two distinct bats with significantly different inertial properties. Model output included bat trajectories, subject/bat interaction forces and torques, work, and power. These data formed the basis for a detailed analysis and description of fundamental swing kinematic and kinetic quantities. The analyses revealed that the softball swing is a highly coordinated and individual three-dimensional motion and subject-to-subject variations were significant in all kinematic and kinetic quantities. In addition, the potential effects of bat properties on swing mechanics are discussed. The paths of the hands and the centre-of-curvature of the bat relative to the horizontal plane appear to be important trajectory characteristics of the swing. Descriptions of the swing mechanics and practical implications are offered based upon these findings.

  4. Robotic Hand Controlling Based on Flexible Sensor

    OpenAIRE

    Bilgin, Süleyman; Üser, Yavuz; Mercan, Muhammet

    2016-01-01

    Today's technology has increased the interest in robotic systems andincrease the number of studies realized in this area.  There are many studies on robotic systems inseveral fields to facilitate human life in the literature. In this study, arobot hand is designed to repeat finger movements depending upon flexiblesensors mounted on any wearable glove. In the literature, various sensors thatdetect the finger movement are used. The sensor that detects the angle of thefingers has b...

  5. Robotic Hand

    Science.gov (United States)

    1993-01-01

    The Omni-Hand was developed by Ross-Hime Designs, Inc. for Marshall Space Flight Center (MSFC) under a Small Business Innovation Research (SBIR) contract. The multiple digit hand has an opposable thumb and a flexible wrist. Electric muscles called Minnacs power wrist joints and the interchangeable digits. Two hands have been delivered to NASA for evaluation for potential use on space missions and the unit is commercially available for applications like hazardous materials handling and manufacturing automation. Previous SBIR contracts resulted in the Omni-Wrist and Omni-Wrist II robotic systems, which are commercially available for spray painting, sealing, ultrasonic testing, as well as other uses.

  6. Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography

    Directory of Open Access Journals (Sweden)

    Hannes Höppner

    2017-05-01

    Full Text Available We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands.

  7. Kinetics of Human Haematopoiesis

    Energy Technology Data Exchange (ETDEWEB)

    Cronkite, E. P. [Forschungsgruppe Freiburg, Institut fuer Haematologie der Gesellschaft fuer Strahlenforschung Assoziation mit EURATOM, Freiburg/Breisgau, Federal Republic of Germany (Germany); Medical Research Center, Brookhaven National Laboratory, Upton, Long Island, NY (United States)

    1967-07-15

    An understanding of the parameters of normal cell proliferation is a prerequisite for the understanding of the disturbances induced by radiation. The disturbances induced by radiation on cell renewal systems has been presented in detail by Bond, Fliedner and Archambeau. In this paper a method of studying the concepts and actual observations on human haemopoiesis will be summarized. Details of the procedures, methods and concepts are published. The method employed is the serial.autoradiographic study of haemopoietic tissues after labelling the DNA of proliferating compartments by intravenous injection of tritiated thymidine (3HTDR) a specific DNA precursor. One can then observe the flow of labelled cells through mitosis, the transit of labelled cells from a proliferating compartment to a non proliferating compartment and the migration of cells from tissues to blood.

  8. Using postural synergies to animate a low-dimensional hand avatar in haptic simulation.

    Science.gov (United States)

    Mulatto, Sara; Formaglio, Alessandro; Malvezzi, Monica; Prattichizzo, Domenico

    2013-01-01

    A technique to animate a realistic hand avatar with 20 DoFs based on the biomechanics of the human hand is presented. The animation does not use any sensor glove or advanced tracker with markers. The proposed approach is based on the knowledge of a set of kinematic constraints on the model of the hand, referred to as postural synergies, which allows to represent the hand posture using a number of variables lower than the number of joints of the hand model. This low-dimensional set of parameters is estimated from direct measurement of the motion of thumb and index finger tracked using two haptic devices. A kinematic inversion algorithm has been developed, which takes synergies into account and estimates the kinematic configuration of the whole hand, i.e., also of the fingers whose end tips are not directly tracked by the two haptic devices. The hand skin is deformable and its deformation is computed using a linear vertex blending technique. The proposed synergy-based animation of the hand avatar involves only algebraic computations and is suitable for real-time implementation as required in haptics.

  9. Robotic approaches for rehabilitation of hand function after stroke.

    Science.gov (United States)

    Lum, Peter S; Godfrey, Sasha B; Brokaw, Elizabeth B; Holley, Rahsaan J; Nichols, Diane

    2012-11-01

    The goal of this review was to discuss the impairments in hand function after stroke and present previous work on robot-assisted approaches to movement neurorehabilitation. Robotic devices offer a unique training environment that may enhance outcomes beyond what is possible with conventional means. Robots apply forces to the hand, allowing completion of movements while preventing inappropriate movement patterns. Evidence from the literature is emerging that certain characteristics of the human-robot interaction are preferable. In light of this evidence, the robotic hand devices that have undergone clinical testing are reviewed, highlighting the authors' work in this area. Finally, suggestions for future work are offered. The ability to deliver therapy doses far higher than what has been previously tested is a potentially key advantage of robotic devices that needs further exploration. In particular, more efforts are needed to develop highly motivating home-based devices, which can increase access to high doses of assisted movement therapy.

  10. In pursuit of our ancestors' hand laterality.

    Science.gov (United States)

    Bargalló, Amèlia; Mosquera, Marina; Lozano, Sergi

    2017-10-01

    The aim of this paper is to apply a previously published method (Bargalló and Mosquera, 2014) to the archaeological record, allowing us to identify the hand laterality of our ancestors and determine when and how this feature, which is exhibited most strongly in humans, appeared in our evolutionary history. The method focuses on identifying handedness by looking at the technical features of the flakes produced by a single knapper, and discovering how many flakes are required to ascertain their hand preference. This method can potentially be applied to the majority of archaeological sites, since flakes are the most abundant stone tools, and stone tools are the most widespread and widely-preserved remains from prehistory. For our study, we selected two Spanish sites: Gran Dolina-TD10.1 (Atapuerca) and Abric Romaní (Barcelona), which were occupied by pre-Neanderthal and Neanderthal populations, respectively. Our analyses indicate that a minimum number of eight flakes produced by the same knapper is required to ascertain their hand preference. Even though this figure is relatively low, it is quite difficult to obtain from many archaeological sites. In addition, there is no single technical feature that provides information about handedness, instead there is a combination of eight technical features, localised on the striking platforms and ventral surfaces. The raw material is not relevant where good quality rocks are used, in this case quartzite and flint, since most of them retain the technical features required for the analysis. Expertise is not an issue either, since the technical features analysed here only correlate with handedness (Bargalló and Mosquera, 2014). Our results allow us to tentatively identify one right-handed knapper among the pre-Neanderthals of level TD10.1 at Gran Dolina (Atapuerca), while four of the five Neanderthals analysed from Abric Romaní were right-handed. The hand preference of the fifth knapper from that location (AR5) remains unclear

  11. Hands in Systemic Disease

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is ... Hand Therapist? Media Find a Hand Surgeon Home Anatomy ... hands, being composed of many types of tissue, including blood vessels, nerves, skin and skin-related tissues, bones, and muscles/tendons/ligaments, may show changes that reflect a ...

  12. The biomechanics of upper extremity kinematic and kinetic modeling: applications to rehabilitation engineering.

    Science.gov (United States)

    Slavens, Brooke A; Harris, Gerald F

    2008-01-01

    Human motion analysis has evolved from the lower extremity to the upper extremity. Rehabilitation engineering is reliant upon three-dimensional biome-chanical models for a thorough understanding of upper body motions and forces in order to improve treatment methods, rehabilitation strategies and to prevent injury. Due to the complex nature of upper body movements, a standard biomechanical model does not exist. This paper reviews several kinematic and kinetic rehabilitation engineering models from the literature. These models may capture a single joint; multijoints such as the shoulder, elbow and wrist; or a combination of joints and an ambulatory aid, which serves as the extension of the upper arm. With advances in software and hardware, new models continuously arise due to the clinical questions at hand. When designing a biomechanical upper extremity model, several key components must be determined. These include deciding on the anatomic segments of the model, the number of markers and placement on bony landmarks, the definition of joint coordinate systems, and the description of the joint motions. It is critical to apply the proper model to further our understanding of pathologic populations.

  13. Evaluation of rate law approximations in bottom-up kinetic models of metabolism

    DEFF Research Database (Denmark)

    Du, Bin; Zielinski, Daniel C.; Kavvas, Erol S.

    2016-01-01

    mass action rate law that removes the role of the enzyme from the reaction kinetics. We utilized in vivo data for the human red blood cell to compare the effect of rate law choices against the backdrop of physiological flux and concentration differences. We found that the Michaelis-Menten rate law......Background: The mechanistic description of enzyme kinetics in a dynamic model of metabolism requires specifying the numerical values of a large number of kinetic parameters. The parameterization challenge is often addressed through the use of simplifying approximations to form reaction rate laws....... These approximate rate laws were: 1) a Michaelis-Menten rate law with measured enzyme parameters, 2) a Michaelis-Menten rate law with approximated parameters, using the convenience kinetics convention, 3) a thermodynamic rate law resulting from a metabolite saturation assumption, and 4) a pure chemical reaction...

  14. Tumor cell proliferation kinetics and tumor growth rate

    Energy Technology Data Exchange (ETDEWEB)

    Tubiana, M

    1989-01-01

    The present knowledge on the growth rate and the proliferation kinetics of human tumor is based on the measurement of the tumor doubling times (DT) in several hundred patients and on the determination of the proportion of proliferating cells with radioactive thymidine or by flow cytometry in large numbers of patients. The results show that the DT of human tumor varies widely, from less than one week to over one year with a median value of approximately 2 months. The DTs are significantly correlated with the histological type. They depend upon (1) the duration of the cell cycle whose mean duration is 2 days with small variations from tumor to tumor, (2) the proportion of proliferating cells and consequently the cell birth rate which varies widely among tumors and which is significantly correlated to the DT, (3) the cell loss factors which also vary widely and which are the greatest when proliferation is most intensive. These studies have several clinical implications: (a) they have further increased our understanding of the natural history of human tumor, (b) they have therapeutic implications since tumor responsiveness and curability by radiation and drugs are strongly influenced by the cell kinetic parameters of the tumor, (c) the proportion of proliferating cells is of great prognostic value in several types of human cancers. The investigation of the molecular defects, which are correlated with the perturbation of control of cell proliferation, should lead to significant fundamental and therapeutic advances. (orig.).

  15. Complementary hand responses occur in both peri- and extrapersonal space

    NARCIS (Netherlands)

    Faber, T.W.; van Elk, M.; Jonas, K.J.

    2016-01-01

    Human beings have a strong tendency to imitate. Evidence from motor priming paradigms suggests that people automatically tend to imitate observed actions such as hand gestures by performing mirror-congruent movements (e.g., lifting one’s right finger upon observing a left finger movement; from a

  16. Hand Hygiene – Evaluation of Three Disinfectant Hand Sanitizers in a Community Setting

    Science.gov (United States)

    Babeluk, Rita; Jutz, Sabrina; Mertlitz, Sarah; Matiasek, Johannes; Klaus, Christoph

    2014-01-01

    Hand hygiene is acknowledged as the single most important measure to prevent nosocomial infections in the healthcare setting. Similarly, in non-clinical settings, hand hygiene is recognised as a key element in helping prevent the spread of infectious diseases. The aim of this study was to evaluate the efficacy of three different disinfectant hand sanitizers in reducing the burden of bacterial hand contamination in 60 healthy volunteers in a community setting, both before and after education about the correct use of hand sanitizers. The study is the first to evaluate the efficacy and ease of use of different formulations of hand rubs used by the general population. The products tested were: Sterillium (perfumed, liquid), desderman pure gel (odorless, gel) and Lavit (perfumed, spray). Sterillium and desderman are EN1500 (hygienic hand rub) certified products (available in pharmacy) and Lavit is non EN1500 certified and available in supermarkets. The two EN1500 certified products were found to be significantly superior in terms of reducing bacterial load. desderman pure gel, Sterillium and Lavit reduced the bacterial count to 6.4%, 8.2% and 28.0% respectively. After education in the correct use of each hand rub, the bacterial load was reduced even further, demonstrating the value of education in improving hand hygiene. Information about the testers' perceptions of the three sanitizers, together with their expectations of a hand sanitizer was obtained through a questionnaire. Efficacy, followed by skin compatibility were found to be the two most important attributes of a hand disinfectant in our target group. PMID:25379773

  17. Efficacy of alcohol-based hand sanitizer on hands soiled with dirt and cooking oil.

    Science.gov (United States)

    Pickering, Amy J; Davis, Jennifer; Boehm, Alexandria B

    2011-09-01

    Handwashing education and promotion are well established as effective strategies to reduce diarrhea and respiratory illness in countries around the world. However, access to reliable water supplies has been identified as an important barrier to regular handwashing in low-income countries. Alcohol-based hand sanitizer (ABHS) is an effective hand hygiene method that does not require water, but its use is not currently recommended when hands are visibly soiled. This study evaluated the efficacy of ABHS on volunteers' hands artificially contaminated with Escherichia coli in the presence of dirt (soil from Tanzania) and cooking oil. ABHS reduced levels of E. coli by a mean of 2.33 log colony forming units (CFU) per clean hand, 2.32 log CFU per dirt-covered hand, and 2.13 log CFU per oil-coated hand. No significant difference in efficacy was detected between hands that were clean versus dirty or oily. ABHS may be an appropriate hand hygiene method for hands that are moderately soiled, and an attractive option for field settings in which access to water and soap is limited.

  18. "Puffy hand syndrome".

    Science.gov (United States)

    Chouk, Mickaël; Vidon, Claire; Deveza, Elise; Verhoeven, Frank; Pelletier, Fabien; Prati, Clément; Wendling, Daniel

    2017-01-01

    Intravenous drug addiction is responsible for many complications, especially cutaneous and infectious. There is a syndrome, rarely observed in rheumatology, resulting in "puffy hands": the puffy hand syndrome. We report two cases of this condition from our rheumatologic consultation. Our two patients had intravenous drug addiction. They presented with an edema of the hands, bilateral, painless, no pitting, occurring in one of our patient during heroin intoxication, and in the other 2 years after stopping injections. In our two patients, additional investigations (biological, radiological, ultrasound) were unremarkable, which helped us, in the context, to put the diagnosis of puffy hand syndrome. The pathophysiology, still unclear, is based in part on a lymphatic toxicity of drugs and their excipients. There is no etiological treatment but elastic compression by night has improved edema of the hands in one of our patients. Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  19. Tracking and Classification of In-Air Hand Gesture Based on Thermal Guided Joint Filter

    Directory of Open Access Journals (Sweden)

    Seongwan Kim

    2017-01-01

    Full Text Available The research on hand gestures has attracted many image processing-related studies, as it intuitively conveys the intention of a human as it pertains to motional meaning. Various sensors have been used to exploit the advantages of different modalities for the extraction of important information conveyed by the hand gesture of a user. Although many works have focused on learning the benefits of thermal information from thermal cameras, most have focused on face recognition or human body detection, rather than hand gesture recognition. Additionally, the majority of the works that take advantage of multiple modalities (e.g., the combination of a thermal sensor and a visual sensor, usually adopting simple fusion approaches between the two modalities. As both thermal sensors and visual sensors have their own shortcomings and strengths, we propose a novel joint filter-based hand gesture recognition method to simultaneously exploit the strengths and compensate the shortcomings of each. Our study is motivated by the investigation of the mutual supplementation between thermal and visual information in low feature level for the consistent representation of a hand in the presence of varying lighting conditions. Accordingly, our proposed method leverages the thermal sensor’s stability against luminance and the visual sensors textural detail, while complementing the low resolution and halo effect of thermal sensors and the weakness against illumination of visual sensors. A conventional region tracking method and a deep convolutional neural network have been leveraged to track the trajectory of a hand gesture and to recognize the hand gesture, respectively. Our experimental results show stability in recognizing a hand gesture against varying lighting conditions based on the contribution of the joint kernels of spatial adjacency and thermal range similarity.

  20. Peak Muscle Activation, Joint Kinematics, and Kinetics during Elliptical and Stepping Movement Pattern on a Precor Adaptive Motion Trainer

    Science.gov (United States)

    Rogatzki, Matthew J.; Kernozek, Thomas W.; Willson, John D.; Greany, John F.; Hong, Di-An; Porcari, John P.

    2012-01-01

    Kinematic, kinetic, and electromyography data were collected from the biceps femoris, rectus femoris (RF), gluteus maximus, and erector spinae (ES) during a step and elliptical exercise at a standardized workload with no hand use. Findings depicted 95% greater ankle plantar flexion (p = 0.01), 29% more knee extension (p = 0.003), 101% higher peak…

  1. Brain kinetics of L-[β-11C]DOPA in humans studied by positron emission tomography

    International Nuclear Information System (INIS)

    Hartvig, P.; Agren, H.; Reibring, L.; Tedroff, J.; Bjurling, P.; Kihlberg, T.; Langstroem, B.

    1991-01-01

    The in vivo dopamine precursor L-3,4-dihydroxyphenylalanine (L-DOPA) labelled with 11 C in the β position has been used for positron emission tomography studies of L-DOPA utilization in the brain. The brain uptake and kinetics of L-[ 11 C]DOPA-derived radioactivity were studied in healthy male volunteers, and the specific utilization, i.e. decarboxylation rate of L-[ 11 C]DOPA in different brain areas, was quantified using a brain region devoid of specific L-[ 11 C]DOPA utilization as reference. Total uptake of L-[ 11 C]DOPA-derived radioactivity measured in the brain varied two- to three-fold between subjects, with highest radioactivity in the striatal region. Specific utilization of L-[ 11 C]DOPA radioactivity in the striatal region and in the prefrontal cortex varied twofold between subjects. No specific utilization was observed in other regions of the brain. The uptake of radioactivity in the brain increased dose-dependently with the simultaneous administration of unlabelled L-DOPA up to 10 mg. On the other hand, a decrease in brain radioactivity uptake was measured after pretreatment with 1 mg/kg oral L-DOPA, indicating competition for transport across the blood-brain barrier. Benserazide 0.5mg/kg orally increased somewhat the radioactivity uptake to the brain. None of these pharmacological perturbations demonstrated any clearcut effect on specific utilization of L-[ 11 C]DOPA. Thus, 11 C-labelled L-DOPA is introduced as an alternative to the well-established L-6-[ 18 F]fluoro-DOPA methodology in clinical studies on brain L-DOPA uptake and dopamine synthesis. (authors)

  2. Hand eczema classification

    DEFF Research Database (Denmark)

    Diepgen, T L; Andersen, Klaus Ejner; Brandao, F M

    2008-01-01

    of the disease is rarely evidence based, and a classification system for different subdiagnoses of hand eczema is not agreed upon. Randomized controlled trials investigating the treatment of hand eczema are called for. For this, as well as for clinical purposes, a generally accepted classification system...... A classification system for hand eczema is proposed. Conclusions It is suggested that this classification be used in clinical work and in clinical trials....

  3. KINETICS OF THE OXIDATION OF VITAMIN C

    Directory of Open Access Journals (Sweden)

    Sitti Rahmawati

    2012-12-01

    Full Text Available Vitamin C or ascorbic acid is needed by the human body but it is already damaged by the rise in temperature due to be oxidized to L-dehydroascorbic acid. This research aims to determine the kinetics of oxidation of ascorbic acid due to an increase if temperature (40-80 °C and to design an ascorbic acid oxidation reaction laboratory module to be applied in the senior high school reaction kinetics curriculum. The determination of the kinetics of the oxidation of ascorbic acid applies the integral and half-change time methods, while the concentration of the remained ascorbic acid in sixty minute intervals is determined by iodimetric titration method. Decomposition of ascorbic acid was measured at 40, 50, 60, 70 and 80 °C. The results of this research indicate that at 40, 50, 60, 70 and 80 °C the kinetics of the oxidation of ascorbic acid is a first-order reaction with rate constants of 4.55 x 10-4, 5.85 x 10-4, 8.4 x 10-4, 1.1 x 10-3 and 1.015 x 10-3 min-1, respectively. Pre-exponential factor or the frequency of collisions is a factor which is a measure of the collision rate. The activation energy and the pre-exponential factor for the oxidation of ascorbic acid were found to be 20.73 kJ.mol-1 and 1.372 min-1. The procedure used in this study was modified into a laboratory module will be applied in the teaching of reaction kinetics at the senior high school level.

  4. Advanced dexterous manipulation for IED defeat : report on the feasibility of using the ShadowHand for remote operations.

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Robert J.

    2011-01-01

    Improvised Explosive Device (IED) defeat (IEDD) operations can involve intricate operations that exceed the current capabilities of the grippers on board current bombsquad robots. The Shadow Dexterous Hand from the Shadow Robot Company or 'ShadowHand' for short (www.shadowrobot.com) is the first commercially available robot hand that realistically replicates the motion, degrees-of-freedom and dimensions of a human hand (Figure 1). In this study we evaluate the potential for the ShadowHand to perform potential IED defeat tasks on a mobile platform.

  5. The sound of one-hand clapping: handedness and perisylvian neural correlates of a communicative gesture in chimpanzees.

    Science.gov (United States)

    Meguerditchian, Adrien; Gardner, Molly J; Schapiro, Steven J; Hopkins, William D

    2012-05-22

    Whether lateralization of communicative signalling in non-human primates might constitute prerequisites of hemispheric specialization for language is unclear. In the present study, we examined (i) hand preference for a communicative gesture (clapping in 94 captive chimpanzees from two research facilities) and (ii) the in vivo magnetic resonance imaging brain scans of 40 of these individuals. The preferred hand for clapping was defined as the one in the upper position when the two hands came together. Using computer manual tracing of regions of interest, we measured the neuroanatomical asymmetries for the homologues of key language areas, including the inferior frontal gyrus (IFG) and planum temporale (PT). When considering the entire sample, there was a predominance of right-handedness for clapping and the distribution of right- and left-handed individuals did not differ between the two facilities. The direction of hand preference (right- versus left-handed subjects) for clapping explained a significant portion of variability in asymmetries of the PT and IFG. The results are consistent with the view that gestural communication in the common ancestor may have been a precursor of language and its cerebral substrates in modern humans.

  6. A kinetic model for impact/sliding wear of pressurized water reactor internal components. Application to rod cluster control assemblies

    International Nuclear Information System (INIS)

    Zbinden, M.; Durbec, V.

    1996-12-01

    A new concept of industrial wear model adapted to components of nuclear plants is proposed. Its originality is to be supported, on one hand, by experimental results obtained via wear machines of relatively short operational times, and, on the other hand, by the information obtained from the operating feedback over real wear kinetics of the reactors components. The proposed model is illustrated by an example which corresponds to a specific real situation. The determination of the coefficients permitting to cover all assembly of configurations and the validation of the model in these configurations have been the object of the most recent work. (author)

  7. New hand at the helm of CERN Human Resources

    CERN Document Server

    2004-01-01

    Human resources is more than just an administrative function, said CERN's new HR Department head, Carla Bryois, in an interview with the Bulletin. Human resources management is about getting the best out of an organization's staff. That's good for the organisation as a whole, and it's good for the individual. A suitable task for a psychologist, you might think? And that's exactly the kind of person who has just taken over as head of CERN's Human Resources Department. Carla Bryois, who has Dutch and Swiss nationality, took up her duties on 1 April, and brings with her a wealth of experience from the private sector. Her career began with a degree in psychology and social sciences from the Geneva school made famous by Jean Piaget. From there, she went on to specialise in clinical psychology before taking a career break to raise a family. Carla Bryois, CERN's new HR Department head Returning to work, she moved from academic to occupational psychology, taking up a position in human resources with Elsevier scien...

  8. New frontiers in the rubber hand experiment: when a robotic hand becomes one's own.

    Science.gov (United States)

    Caspar, Emilie A; De Beir, Albert; Magalhaes De Saldanha Da Gama, Pedro A; Yernaux, Florence; Cleeremans, Axel; Vanderborght, Bram

    2015-09-01

    The rubber hand illusion is an experimental paradigm in which participants consider a fake hand to be part of their body. This paradigm has been used in many domains of psychology (i.e., research on pain, body ownership, agency) and is of clinical importance. The classic rubber hand paradigm nevertheless suffers from limitations, such as the absence of active motion or the reliance on approximate measurements, which makes strict experimental conditions difficult to obtain. Here, we report on the development of a novel technology-a robotic, user- and computer-controllable hand-that addresses many of the limitations associated with the classic rubber hand paradigm. Because participants can actively control the robotic hand, the device affords higher realism and authenticity. Our robotic hand has a comparatively low cost and opens up novel and innovative methods. In order to validate the robotic hand, we have carried out three experiments. The first two studies were based on previous research using the rubber hand, while the third was specific to the robotic hand. We measured both sense of agency and ownership. Overall, results show that participants experienced a "robotic hand illusion" in the baseline conditions. Furthermore, we also replicated previous results about agency and ownership.

  9. The Case for Hand Stencils and Prints as Proprio-Performative

    Directory of Open Access Journals (Sweden)

    Patricia Dobrez

    2013-12-01

    Full Text Available Hand stencils and prints are found globally in rock art, reflecting the sine qua non role of the hand in human evolution. The body itself is the tool, and it affords the registering, in the form of a trace, of what perceptual psychology terms an “ecological self”. More than a “signature”, a hand mark is uniquely “proprio-performative”, combining inscription of individuality with direct address. The first part of this paper looks at what might get in the way of a universally readable primary meaning by methodically addressing issues of technique and cultural specificity. Having cleared the ground, it proceeds to make its argument for hand stencils and prints as constituting a special category of rock art imagery. It does this by having recourse to ideas currently under discussion in cognitive psychology: awareness of self-agency and body-ownership, as well as the notion of perceived looming in pictures. Finally, an appeal is made to the claim for a key mirror neuron role in communication. Because they are traces of actions eliciting mirror-neuronal responses, hand marks are seen as affording a readily accessible external term in an exchange of meaning on which a system of graphic communication might be built.

  10. Training-induced acceleration of O(2) uptake on-kinetics precedes muscle mitochondrial biogenesis in humans.

    Science.gov (United States)

    Zoladz, Jerzy A; Grassi, Bruno; Majerczak, Joanna; Szkutnik, Zbigniew; Korostyński, Michał; Karasiński, Janusz; Kilarski, Wincenty; Korzeniewski, Bernard

    2013-04-01

    The effects of 5 weeks of moderate-intensity endurance training on pulmonary oxygen uptake kinetics (V(O(2)) on-kinetics) were studied in 15 healthy men (mean ± SD: age 22.7 ± 1.8 years, body weight 76.4 ± 8.9 kg and maximal V(O(2)) 46.0 ± 3.7 ml kg(-1) min(-1)). Training caused a significant acceleration (P = 0.003) of V(O(2)) on-kinetics during moderate-intensity cycling (time constant of the 'primary' component 30.0 ± 6.6 versus 22.8 ± 5.6 s before and after training, respectively) and a significant decrease (P = 0.04) in the amplitude of the primary component (837 ± 351 versus 801 ± 330 ml min(-1)). No changes in myosin heavy chain distribution, muscle fibre capillarization, level of peroxisome proliferator-activated receptor γ coactivator 1α and other markers of mitochondrial biogenesis (mitochondrial DNA copy number, cytochrome c and cytochrome oxidase subunit I contents) in the vastus lateralis were found after training. A significant downregulation in the content of the sarcoplasmic reticulum ATPase 2 (SERCA2; P = 0.03) and a tendency towards a decrease in SERCA1 (P = 0.055) was found after training. The decrease in SERCA1 was positively correlated (P = 0.05) with the training-induced decrease in the gain of the V(O(2)) on-kinetics (ΔV(O(2)) at steady state/Δpower output). In the early stage of training, the acceleration in V(O(2)) on-kinetics during moderate-intensity cycling can occur without enhanced mitochondrial biogenesis or changes in muscle myosin heavy chain distribution and in muscle fibre capillarization. The training-induced decrease of the O(2) cost of cycling could be caused by the downregulation of SERCA pumps.

  11. BrailleEasy: One-handed Braille Keyboard for Smartphones.

    Science.gov (United States)

    Šepić, Barbara; Ghanem, Abdurrahman; Vogel, Stephan

    2015-01-01

    The evolution of mobile technology is moving at a very fast pace. Smartphones are currently considered a primary communication platform where people exchange voice calls, text messages and emails. The human-smartphone interaction, however, is generally optimized for sighted people through the use of visual cues on the touchscreen, e.g., typing text by tapping on a visual keyboard. Unfortunately, this interaction scheme renders smartphone technology largely inaccessible to visually impaired people as it results in slow typing and higher error rates. Apple and some third party applications provide solutions specific to blind people which enables them to use Braille on smartphones. These applications usually require both hands for typing. However, Brailling with both hands while holding the phone is not very comfortable. Furthermore, two-handed Brailling is not possible on smartwatches, which will be used more pervasively in the future. Therefore, we develop a platform for one-handed Brailing consisting of a custom keyboard called BrailleEasy to input Arabic or English Braille codes within any application, and a BrailleTutor application for practicing. Our platform currently supports Braille grade 1, and will be extended to support contractions, spelling correction, and more languages. Preliminary analysis of user studies for blind participants showed that after less than two hours of practice, participants were able to type significantly faster with the BrailleEasy keyboard than with the standard QWERTY keyboard.

  12. Comparison of shoulder load during power-assisted and purely hand-rim wheelchair propulsion.

    Science.gov (United States)

    Kloosterman, Marieke G M; Eising, Hilde; Schaake, Leendert; Buurke, Jaap H; Rietman, Johan S

    2012-06-01

    Repetitive forces and moments are among the work requirements of hand-rim wheelchair propulsion that are related to shoulder injuries. No previous research has been published about the influence of power-assisted wheelchair propulsion on these work requirements. The purpose of our study was therefore to determine the influence of power-assisted propulsion on shoulder biomechanics and muscle activation patterns. We also explored the theoretical framework for the effectiveness of power-assisted propulsion in preventing shoulder injuries by decreasing the work requirements of hand-rim wheelchair propulsion. Nine non-wheelchair users propelled a hand-rim wheelchair on a treadmill at 0.9 m/s. Shoulder biomechanics, and muscle activation patterns, were compared between propulsion with and without power-assist. Propulsion frequency did not differ significantly between the two conditions (Wilcoxon Signed Rank test/significance level/effect size:4/.314/-.34). During power-assisted propulsion we found significantly decreased maximum shoulder flexion and internal rotation angles (1/.015/-.81 and 0/.008/-.89) and decreased peak force on the rim (0/.008/-.89). This resulted in decreased shoulder flexion, adduction and internal rotation moments (2/.021/-.77; 0/.008/-.89 and 1/.011/-.85) and decreased forces at the shoulder in the posterior, superior and lateral directions (2/.021/-.77; 2/.008/-.89 and 2/.024/-.75). Muscle activation in the pectoralis major, posterior deltoid and triceps brachii was also decreased (2/.038/-.69; 1/.015/-.81 and 1/.021/-.77). Power-assist influenced the work requirements of hand-rim wheelchair propulsion by healthy subjects. It was primarily the kinetics at rim and shoulder which were influenced by power-assisted propulsion. Additional research with actual hand-rim wheelchair users is required before extrapolation to routine clinical practice. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Hand Hygiene: When and How

    Science.gov (United States)

    Hand Hygiene When and How August 2009 How to handrub? How to handwash? RUB HANDS FOR HAND HYGIENE! WASH HANDS WHEN VISIBLY SOILED Duration of the ... its use. When? YOUR 5 MOMENTS FOR HAND HYGIENE 1 BEFORETOUCHINGA PATIENT 2 B P ECFLOER R ...

  14. Pre-Steady State Kinetic Investigation of the Incorporation of Anti-Hepatitis B Nucleotide Analogs Catalyzed by Non-Canonical Human DNA Polymerases

    Science.gov (United States)

    Brown, Jessica A.; Pack, Lindsey R.; Fowler, Jason D.; Suo, Zucai

    2011-01-01

    Antiviral nucleoside analogs have been developed to inhibit the enzymatic activities of the hepatitis B virus (HBV) polymerase, thereby preventing the replication and production of HBV. However, the usage of these analogs can be limited by drug toxicity because the 5′-triphosphates of these nucleoside analogs (nucleotide analogs) are potential substrates for human DNA polymerases to incorporate into host DNA. Although they are poor substrates for human replicative DNA polymerases, it remains to be established whether these nucleotide analogs are substrates for the recently discovered human X- and Y-family DNA polymerases. Using pre-steady state kinetic techniques, we have measured the substrate specificity values for human DNA polymerases β, λ, η, ι, κ, and Rev1 incorporating the active forms of the following anti-HBV nucleoside analogs approved for clinical use: adefovir, tenofovir, lamivudine, telbivudine, and entecavir. Compared to the incorporation of a natural nucleotide, most of the nucleotide analogs were incorporated less efficiently (2 to >122,000) by the six human DNA polymerases. In addition, the potential for entecavir and telbivudine, two drugs which possess a 3′-hydroxyl, to become embedded into human DNA was examined by primer extension and DNA ligation assays. These results suggested that telbivudine functions as a chain terminator while entecavir was efficiently extended by the six enzymes and was a substrate for human DNA ligase I. Our findings suggested that incorporation of anti-HBV nucleotide analogs catalyzed by human X- and Y-family polymerases may contribute to clinical toxicity. PMID:22132702

  15. Is the hand to speech what speech is to the hand?

    Science.gov (United States)

    Mildner, V

    2000-01-01

    Interference between the manual and the verbal performance on two types of concurrent verbal-manual tasks was studied on a sample of 48 female right-handers. The more complex verbal task (storytelling) affected both hands significantly, the less complex (essentially phonemic) task affected only the right hand, with insignificant negative influence on the left-hand performance. No significant reciprocal effects of the motor task on verbalization were found.

  16. Effect of Human and Bovine Serum Albumin on kinetic Chemiluminescence of Mn (III-Tetrakis (4-Sulfonatophenyl Porphyrin-Luminol-Hydrogen Peroxide System

    Directory of Open Access Journals (Sweden)

    Sayed Yahya Kazemi

    2012-01-01

    Full Text Available The present work deals with an attempt to study the effect of human and bovine serum albumin on kinetic parameters of chemiluminescence of luminol-hydrogen peroxide system catalyzed by manganese tetrasulfonatophenyl porphyrin (MnTSPP. The investigated parameters involved pseudo-first-order rise and fall rate constant for the chemiluminescence burst, maximum level intensity, time to reach maximum intensity, total light yield, and values of the intensity at maximum CL which were evaluated by nonlinear least square program KINFIT. Because of interaction of metalloporphyrin with proteins, the CL parameters are drastically affected. The systems resulted in Stern-Volmer plots with values of 3.17×105 and 3.7×105M−1 in the quencher concentration range of 1.5×10−6 to 1.5×10−5 M for human serum albumin (HSA and bovine serum albumin (BSA, respectively.

  17. Hand hygiene in reducing transient flora on the hands of healthcare workers: an educational intervention.

    Science.gov (United States)

    Kapil, R; Bhavsar, H K; Madan, M

    2015-01-01

    Hand hygiene has now been recognised as one of the most effective intervention to control the transmission of infections in a hospital and education is an important tool to ensure its implementation. In order to convince the users and as a part of education, it is important to generate evidence on the role of hand hygiene in reducing the bacterial flora on their hands. The present study was undertaken in a tertiary care hospital to demonstrate the presence of bacterial flora on the hands of healthcare workers (HCW) in different categories, to teach them proper hand hygiene technique using alcohol-based hand rub and determine the outcome for reduction of bacteria. A total sample size of 60 subjects including resident doctors, medical students, nurses and hospital attendants were included in the study after obtaining informed consent. Each person was educated on the technique of hand hygiene with alcohol-based hand rub and hand impressions were cultured before and after hand hygiene. All the subjects were also given a questionnaire to assess their perception on hand hygiene. The WHO posters on proper hand hygiene were displayed in the appropriate areas of the hospital in addition, as an educational tool. Majority (42 out of 60) of the HCWs had bacterial count up to 100 colonies or more on both hands before the application of hand rub while working in the hospital. After use of alcohol hand rub with a proper hand hygiene technique, it was found that the percentage reduction was 95-99% among doctors and nurses, 70% among hospital attendants and 50% among sanitary attendants. Staphylococcus aureus was present on the hands of eight persons of which three were methicillin-resistant Staphylococcus aureus. The study demonstrates that transient bacteria are present on the hands of HCWs but majority could be removed by proper hand hygiene, which needs continuous education to be effective. It also shows that active education by demonstrating the proper hand hygiene technique

  18. Is cancer a pure growth curve or does it follow a kinetics of dynamical structural transformation?

    Science.gov (United States)

    González, Maraelys Morales; Joa, Javier Antonio González; Cabrales, Luis Enrique Bergues; Pupo, Ana Elisa Bergues; Schneider, Baruch; Kondakci, Suleyman; Ciria, Héctor Manuel Camué; Reyes, Juan Bory; Jarque, Manuel Verdecia; Mateus, Miguel Angel O'Farril; González, Tamara Rubio; Brooks, Soraida Candida Acosta; Cáceres, José Luis Hernández; González, Gustavo Victoriano Sierra

    2017-03-07

    Unperturbed tumor growth kinetics is one of the more studied cancer topics; however, it is poorly understood. Mathematical modeling is a useful tool to elucidate new mechanisms involved in tumor growth kinetics, which can be relevant to understand cancer genesis and select the most suitable treatment. The classical Kolmogorov-Johnson-Mehl-Avrami as well as the modified Kolmogorov-Johnson-Mehl-Avrami models to describe unperturbed fibrosarcoma Sa-37 tumor growth are used and compared with the Gompertz modified and Logistic models. Viable tumor cells (1×10 5 ) are inoculated to 28 BALB/c male mice. Modified Gompertz, Logistic, Kolmogorov-Johnson-Mehl-Avrami classical and modified Kolmogorov-Johnson-Mehl-Avrami models fit well to the experimental data and agree with one another. A jump in the time behaviors of the instantaneous slopes of classical and modified Kolmogorov-Johnson-Mehl-Avrami models and high values of these instantaneous slopes at very early stages of tumor growth kinetics are observed. The modified Kolmogorov-Johnson-Mehl-Avrami equation can be used to describe unperturbed fibrosarcoma Sa-37 tumor growth. It reveals that diffusion-controlled nucleation/growth and impingement mechanisms are involved in tumor growth kinetics. On the other hand, tumor development kinetics reveals dynamical structural transformations rather than a pure growth curve. Tumor fractal property prevails during entire TGK.

  19. Hand aperture patterns in prehension.

    Science.gov (United States)

    Bongers, Raoul M; Zaal, Frank T J M; Jeannerod, Marc

    2012-06-01

    Although variations in the standard prehensile pattern can be found in the literature, these alternative patterns have never been studied systematically. This was the goal of the current paper. Ten participants picked up objects with a pincer grip. Objects (3, 5, or 7cm in diameter) were placed at 30, 60, 90, or 120cm from the hands' starting location. Usually the hand was opened gradually to a maximum immediately followed by hand closing, called the standard hand opening pattern. In the alternative opening patterns the hand opening was bumpy, or the hand aperture stayed at a plateau before closing started. Two participants in particular delayed the start of grasping with respect to start of reaching, with the delay time increasing with object distance. For larger object distances and smaller object sizes, the bumpy and plateau hand opening patterns were used more often. We tentatively concluded that the alternative hand opening patterns extended the hand opening phase, to arrive at the appropriate hand aperture at the appropriate time to close the hand for grasping the object. Variations in hand opening patterns deserve attention because this might lead to new insights into the coordination of reaching and grasping. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Stochastic theory of interfacial enzyme kinetics: A kinetic Monte Carlo study

    International Nuclear Information System (INIS)

    Das, Biswajit; Gangopadhyay, Gautam

    2012-01-01

    Graphical abstract: Stochastic theory of interfacial enzyme kinetics is formulated. Numerical results of macroscopic phenomenon of lag-burst kinetics is obtained by using a kinetic Monte Carlo approach to single enzyme activity. Highlights: ► An enzyme is attached with the fluid state phospholipid molecules on the Langmuir monolayer. ► Through the diffusion, the enzyme molecule reaches the gel–fluid interface. ► After hydrolysing a phospholipid molecule it predominantly leaves the surface in the lag phase. ► The enzyme is strictly attached to the surface with scooting mode of motion and the burst phase appears. - Abstract: In the spirit of Gillespie’s stochastic approach we have formulated a theory to explore the advancement of the interfacial enzyme kinetics at the single enzyme level which is ultimately utilized to obtain the ensemble average macroscopic feature, lag-burst kinetics. We have provided a theory of the transition from the lag phase to the burst phase kinetics by considering the gradual development of electrostatic interaction among the positively charged enzyme and negatively charged product molecules deposited on the phospholipid surface. It is shown that the different diffusion time scales of the enzyme over the fluid and product regions are responsible for the memory effect in the correlation of successive turnover events of the hopping mode in the single trajectory analysis which again is reflected on the non-Gaussian distribution of turnover times on the macroscopic kinetics in the lag phase unlike the burst phase kinetics.

  1. Separation of oily materials in radioactive waste waters by flotation. Flotation kinetics

    International Nuclear Information System (INIS)

    Flores E, R.M.; Ortiz O, H.B.

    2003-01-01

    The rate of separation of oil and total cobalt in the oleaginous residual water previously treated by coagulation/flocculation with a quaternary ammonium amine (25 mgL -1 ) and with modified anionic polyacrylamide (1.5 mgL -1 ) (pH = 7, G 1 = 300 s -1 and G 2 = 30 s -1 ) was determined. The experimental essays to determine the flotation kinetics, its were carried out using as operation and control parameters the air/solids relationship (G/S 0.35), pressure (P =620 kPa) and volume of air-water mixture (V = 37% of V f ), obtained in previous essays, at two different pressure levels and volume of discharged mixture. The kinetic studies of flotation obtained for the flotation system with conventional air dissolved (DAF) its suggest a first order kinetics that it can be represented by the SCC model. At the same time its show that the separation of the present pollutants in the residual water is governed by the removal velocity of the oil. Meanwhile, the concentration of total Co below 1 mgL -1 , on the other hand, the concentration of the 60 Co at the end of the flotation process resulted smaller than 0.008 Bq/ml, as long as the one 54 Mn were not detectable. (Author)

  2. Short Term Motor-Skill Acquisition Improves with Size of Self-Controlled Virtual Hands.

    Science.gov (United States)

    Ossmy, Ori; Mukamel, Roy

    2017-01-01

    Visual feedback in general, and from the body in particular, is known to influence the performance of motor skills in humans. However, it is unclear how the acquisition of motor skills depends on specific visual feedback parameters such as the size of performing effector. Here, 21 healthy subjects physically trained to perform sequences of finger movements with their right hand. Through the use of 3D Virtual Reality devices, visual feedback during training consisted of virtual hands presented on the screen, tracking subject's hand movements in real time. Importantly, the setup allowed us to manipulate the size of the displayed virtual hands across experimental conditions. We found that performance gains increase with the size of virtual hands. In contrast, when subjects trained by mere observation (i.e., in the absence of physical movement), manipulating the size of the virtual hand did not significantly affect subsequent performance gains. These results demonstrate that when it comes to short-term motor skill learning, the size of visual feedback matters. Furthermore, these results suggest that highest performance gains in individual subjects are achieved when the size of the virtual hand matches their real hand size. These results may have implications for optimizing motor training schemes.

  3. Short Term Motor-Skill Acquisition Improves with Size of Self-Controlled Virtual Hands.

    Directory of Open Access Journals (Sweden)

    Ori Ossmy

    Full Text Available Visual feedback in general, and from the body in particular, is known to influence the performance of motor skills in humans. However, it is unclear how the acquisition of motor skills depends on specific visual feedback parameters such as the size of performing effector. Here, 21 healthy subjects physically trained to perform sequences of finger movements with their right hand. Through the use of 3D Virtual Reality devices, visual feedback during training consisted of virtual hands presented on the screen, tracking subject's hand movements in real time. Importantly, the setup allowed us to manipulate the size of the displayed virtual hands across experimental conditions. We found that performance gains increase with the size of virtual hands. In contrast, when subjects trained by mere observation (i.e., in the absence of physical movement, manipulating the size of the virtual hand did not significantly affect subsequent performance gains. These results demonstrate that when it comes to short-term motor skill learning, the size of visual feedback matters. Furthermore, these results suggest that highest performance gains in individual subjects are achieved when the size of the virtual hand matches their real hand size. These results may have implications for optimizing motor training schemes.

  4. Equilibrium amide hydrogen exchange and protein folding kinetics

    International Nuclear Information System (INIS)

    Bai Yawen

    1999-01-01

    The classical Linderstrom-Lang hydrogen exchange (HX) model is extended to describe the relationship between the HX behaviors (EX1 and EX2) and protein folding kinetics for the amide protons that can only exchange by global unfolding in a three-state system including native (N), intermediate (I), and unfolded (U) states. For these slowly exchanging amide protons, it is shown that the existence of an intermediate (I) has no effect on the HX behavior in an off-pathway three-state system (I↔U↔N). On the other hand, in an on-pathway three-state system (U↔I↔N), the existence of a stable folding intermediate has profound effect on the HX behavior. It is shown that fast refolding from the unfolded state to the stable intermediate state alone does not guarantee EX2 behavior. The rate of refolding from the intermediate state to the native state also plays a crucial role in determining whether EX1 or EX2 behavior should occur. This is mainly due to the fact that only amide protons in the native state are observed in the hydrogen exchange experiment. These new concepts suggest that caution needs to be taken if one tries to derive the kinetic events of protein folding from equilibrium hydrogen exchange experiments

  5. Ground Robotic Hand Applications for the Space Program study (GRASP)

    Science.gov (United States)

    Grissom, William A.; Rafla, Nader I. (Editor)

    1992-01-01

    This document reports on a NASA-STDP effort to address research interests of the NASA Kennedy Space Center (KSC) through a study entitled, Ground Robotic-Hand Applications for the Space Program (GRASP). The primary objective of the GRASP study was to identify beneficial applications of specialized end-effectors and robotic hand devices for automating any ground operations which are performed at the Kennedy Space Center. Thus, operations for expendable vehicles, the Space Shuttle and its components, and all payloads were included in the study. Typical benefits of automating operations, or augmenting human operators performing physical tasks, include: reduced costs; enhanced safety and reliability; and reduced processing turnaround time.

  6. Unimanual SNARC Effect: Hand Matters

    Directory of Open Access Journals (Sweden)

    Marianna eRiello

    2011-12-01

    Full Text Available A structural representation of the hand embedding information about the identity and relative position of fingers is necessary to counting routines. It may also support associations between numbers and allocentric spatial codes that predictably interact with other known numerical spatial representations, such as the mental number line. In this study, 48 Western participants whose typical counting routine proceeded from thumb-to-little on both hands performed magnitude and parity binary judgments. Response keys were pressed either with the right index and middle fingers or with the left index and middle fingers in separate blocks. 24 participants responded with either hands in prone posture (i.e. palm down and 24 participants responded with either hands in supine (i.e. palm up posture. When hands were in prone posture, the counting direction of the left hand conflicted with the direction of the left-right mental number line, whereas the counting direction of the right hand was consistent with it. When hands were in supine posture, the opposite was true. If systematic associations existed between relative number magnitude and an allocentric spatial representation of the finger series within each hand, as predicted on the basis of counting habits, interactions would be expected between hand posture and a unimanual version of the Spatial-Numerical Association of Response Codes (SNARC effect. Data revealed that with hands in prone posture a unimanual SNARC effect was present for the right hand, and with hands in supine posture a unimanual SNARC effect was present for the left hand. We propose that a posture-invariant body structural representation of the finger series provides a relevant frame of reference, a within-hand directional vector, that is associated to simple number processing. Such frame of reference can significantly interact with stimulus-response correspondence effects that have been attributed to the mapping of numbers on a mental

  7. Comparative study of presurgical hand hygiene with hydroalcoholic solution versus traditional presurgical hand hygiene.

    Science.gov (United States)

    López Martín, M Beatriz; Erice Calvo-Sotelo, Alejo

    To compare presurgical hand hygiene with hydroalcoholic solution following the WHO protocol with traditional presurgical hand hygiene. Cultures of the hands of surgeons and surgical nurses were performed before and after presurgical hand hygiene and after removing gloves at the end of surgery. Cultures were done in 2different days: the first day after traditional presurgical hand hygiene, and the second day after presurgical hand hygiene with hydroalcoholic solution following the WHO protocol. The duration of the traditional hand hygiene was measured and compared with the duration (3min) of the WHO protocol. The cost of the products used in the traditional technique was compared with the cost of the hydroalcoholic solution used. The variability of the traditional technique was determined by observation. Following presurgical hand hygiene with hydroalcoholic solution, colony-forming units (CFU) were detected in 5 (7.3%) subjects, whereas after traditional presurgical hand hygiene CFU were detected in 14 subjects (20.5%) (p < 0.05). After glove removal, the numbers of CFU were similar. The time employed in hand hygiene with hydroalcoholic solution (3min) was inferior to the time employed in the traditional technique (p < 0.05), its cost was less than half, and there was no variability. Compared with other techniques, presurgical hand hygiene with hydroalcoholic solution significantly decreases CFU, has similar latency time, a lower cost, and saves time. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  8. Physical kinetics

    International Nuclear Information System (INIS)

    Lifschitz, E.M.; Pitajewski, L.P.

    1983-01-01

    The textbook covers the subject under the following headings: kinetic gas theory, diffusion approximation, collisionless plasma, collisions within the plasma, plasma in the magnetic field, theory of instabilities, dielectrics, quantum fluids, metals, diagram technique for nonequilibrium systems, superconductors, and kinetics of phase transformations

  9. Muscular and pulmonary O2 uptake kinetics during moderate- and high-intensity sub-maximal knee-extensor exercise in humans

    DEFF Research Database (Denmark)

    Krustrup, Peter; Jones, Andrew M.; Wilkerson, Daryl P.

    2009-01-01

    artery to vein and vein to artery). The kinetics of m O2 and p O2 were modelled using non-linear regression. The time constant (tau) describing the phase II p O2 kinetics following the onset of exercise was not significantly different from the mean response time (initial time delay + &tgr) for m O2...... kinetics for LI (30 +/- 3 vs. 30 +/- 3 s) but was slightly higher (P....05; r = -0.01) and HI (33 +/- 3 vs. 27 +/- 3, P>0.05; r = -0.04). MTT was ~17 s just before exercise and decreased to 10 s and 12 s after 5 s of exercise for LI and HI, respectively. These data indicate that the phase II p O2 kinetics reflect m O2 kinetics during exercise but not during recovery where...

  10. Wash Your Hands

    Science.gov (United States)

    ... hand sanitizers might not remove harmful chemicals like pesticides and heavy metals from hands. Be cautious when ... Health Promotion Materials Fact Sheets Podcasts Posters Stickers Videos Web Features Training & Education Our Partners Publications, Data & ...

  11. Robotically enhanced rubber hand illusion.

    Science.gov (United States)

    Arata, Jumpei; Hattori, Masashi; Ichikawa, Shohei; Sakaguchi, Masamichi

    2014-01-01

    The rubber hand illusion is a well-known multisensory illusion. In brief, watching a rubber hand being stroked by a paintbrush while one's own unseen hand is synchronously stroked causes the rubber hand to be attributed to one's own body and to "feel like it's my hand." The rubber hand illusion is thought to be triggered by the synchronized tactile stimulation of both the subject's hand and the fake hand. To extend the conventional rubber hand illusion, we introduce robotic technology in the form of a master-slave telemanipulator. The developed one degree-of-freedom master-slave system consists of an exoskeleton master equipped with an optical encoder that is worn on the subject's index finger and a motor-actuated index finger on the rubber hand, which allows the subject to perform unilateral telemanipulation. The moving rubber hand illusion has been studied by several researchers in the past with mechanically connected rigs between the subject's body and the fake limb. The robotic instruments let us investigate the moving rubber hand illusion with less constraints, thus behaving closer to the classic rubber hand illusion. In addition, the temporal delay between the body and the fake limb can be precisely manipulated. The experimental results revealed that the robotic instruments significantly enhance the rubber hand illusion. The time delay is significantly correlated with the effect of the multisensory illusion, and the effect significantly decreased at time delays over 100 ms. These findings can potentially contribute to the investigations of neural mechanisms in the field of neuroscience and of master-slave systems in the field of robotics.

  12. Inexpensive and Time-Efficient Hand Hygiene Interventions Increase Elementary School Children's Hand Hygiene Rates

    Science.gov (United States)

    Snow, Michelle; White, George L.; Kim, Han S.

    2008-01-01

    Routine hand hygiene has been cited by the World Health Organization and the Centers for Disease Control and Prevention as a cost-effective and important hygiene measure in preventing the spread of infectious diseases. Several studies have explored children's hand hygiene habits, effects of scheduled hand hygiene, hand hygiene environmental…

  13. Neural estimation of kinetic rate constants from dynamic PET-scans

    DEFF Research Database (Denmark)

    Fog, Torben L.; Nielsen, Lars Hupfeldt; Hansen, Lars Kai

    1994-01-01

    A feedforward neural net is trained to invert a simple three compartment model describing the tracer kinetics involved in the metabolism of [18F]fluorodeoxyglucose in the human brain. The network can estimate rate constants from positron emission tomography sequences and is about 50 times faster ...

  14. Evaluation of Human Prehension Using Grasp Quality Measures

    Directory of Open Access Journals (Sweden)

    Beatriz León

    2012-10-01

    Full Text Available One of the main features of the human hand is its grasping ability. Robot grasping has been studied for years and different quality measures have been proposed to evaluate the stability and manipulability of grasps. Although the human hand is obviously more complex than robot hands, the methods used in robotics might be adopted to study the human grasp. The purpose of this work is to propose a set of measures that allow the evaluation of different aspects of the human grasp. The most common robotic grasp quality measures have been adapted to the evaluation of the human hand and a new quality measure – the fatigue index – is proposed in order to incorporate the biomechanical aspect into the evaluation. The minimum set of indices that allows the evaluation of the different aspects of the grasp is obtained from the analysis of a human prehension experiment.

  15. Clean Hands Count

    Science.gov (United States)

    ... intended to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... also aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  16. Programming of left hand exploits task set but that of right hand depends on recent history.

    Science.gov (United States)

    Tang, Rixin; Zhu, Hong

    2017-07-01

    There are many differences between the left hand and the right hand. But it is not clear if there is a difference in programming between left hand and right hand when the hands perform the same movement. In current study, we carried out two experiments to investigate whether the programming of two hands was equivalent or they exploited different strategies. In the first experiment, participants were required to use one hand to grasp an object with visual feedback or to point to the center of one object without visual feedback on alternate trials, or to grasp an object without visual feedback and to point the center of one object with visual feedback on alternating trials. They then performed the tasks with the other hand. The result was that previous pointing task affected current grasping when it was performed by the left hand, but not the right hand. In experiment 2, we studied if the programming of the left (or right) hand would be affected by the pointing task performed on the previous trial not only by the same hand, but also by the right (or left) hand. Participants pointed and grasped the objects alternately with two hands. The result was similar with Experiment 1, i.e., left-hand grasping was affected by right-hand pointing, whereas right-hand grasping was immune from the interference from left hand. Taken together, the results suggest that when open- and closed-loop trials are interleaved, motor programming of grasping with the right hand was affected by the nature of the online feedback on the previous trial only if it was a grasping trial, suggesting that the trial-to-trial transfer depends on sensorimotor memory and not on task set. In contrast, motor programming of grasping with the left hand can use information about the nature of the online feedback on the previous trial to specify the parameters of the movement, even when the type of movement that occurred was quite different (i.e., pointing) and was performed with the right hand. This suggests that

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... today; no cure tomorrow - Duration: 3:10. World Health Organization 75,362 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,404 views 5:46 Hand Washing Technique - ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... today; no cure tomorrow - Duration: 3:10. World Health Organization 74,478 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 views 5:46 Hand Washing Technique - ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... 5 Moments of Hand Hygiene - Duration: 1:53. Salem Health 13,972 views 1:53 Hand Hygiene ... Mode: Off History Help Loading... Loading... Loading... About Press Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & ...

  1. Unimanual SNARC Effect: Hand Matters.

    Science.gov (United States)

    Riello, Marianna; Rusconi, Elena

    2011-01-01

    A structural representation of the hand embedding information about the identity and relative position of fingers is necessary to counting routines. It may also support associations between numbers and allocentric spatial codes that predictably interact with other known numerical spatial representations, such as the mental number line (MNL). In this study, 48 Western participants whose typical counting routine proceeded from thumb-to-little on both hands performed magnitude and parity binary judgments. Response keys were pressed either with the right index and middle fingers or with the left index and middle fingers in separate blocks. 24 participants responded with either hands in prone posture (i.e., palm down) and 24 participants responded with either hands in supine (i.e., palm up) posture. When hands were in prone posture, the counting direction of the left hand conflicted with the direction of the left-right MNL, whereas the counting direction of the right hand was consistent with it. When hands were in supine posture, the opposite was true. If systematic associations existed between relative number magnitude and an allocentric spatial representation of the finger series within each hand, as predicted on the basis of counting habits, interactions would be expected between hand posture and a unimanual version of the spatial-numerical association of response codes (SNARC) effect. Data revealed that with hands in prone posture a unimanual SNARC effect was present for the right hand, and with hands in supine posture a unimanual SNARC effect was present for the left hand. We propose that a posture-invariant body structural representation of the finger series provides a relevant frame of reference, a within-hand directional vector, that is associated to simple number processing. Such frame of reference can significantly interact with stimulus-response correspondence effects, like the SNARC, that have been typically attributed to the mapping of numbers on a left

  2. A person-oriented approach to hand hygiene behaviour: Emotional empathy fosters hand hygiene practice.

    Science.gov (United States)

    Sassenrath, Claudia; Diefenbacher, Svenja; Siegel, André; Keller, Johannes

    2016-01-01

    Adopting a social-psychological approach, this research examines whether emotional empathy, an affective reaction regarding another's well-being, fosters hand hygiene as this affects other's health-related well-being extensively. Three studies tested this notion: (a) a cross-sectional study involving a sample of health care workers at a German hospital, (b) an experiment testing the causal effect of empathy on hand hygiene behaviour and (c) an 11-week prospective study testing whether an empathy induction affected disinfectant usage frequency in two different wards of a hospital. Self-reported hand hygiene behaviour based on day reconstruction method was measured in Study 1, actual hand sanitation behaviour was observed in Study 2 and disinfectant usage frequency in two different hospital wards was assessed in Study 3. Study 1 reveals an association of empathy with hand hygiene cross-sectionally, Study 2 documents the causal effect of empathy on increased hand sanitation. Study 3 shows an empathy induction increases hand sanitiser usage in the hospital. Increasing emotional empathy promotes hand hygiene behaviour, also in hospitals. Besides providing new impulses for the design of effective interventions, these findings bear theoretical significance as they document the explanatory power of empathy regarding a distal explanandum (hand hygiene).

  3. Improved Hand Hygiene Compliance is Associated with the Change of Perception toward Hand Hygiene among Medical Personnel

    Science.gov (United States)

    Park, Se Jeong; Chung, Moon Joo; Lee, Ju Hee; Kang, Hyun Joo; Lee, Jeong-a; Kim, Yong Kyun

    2014-01-01

    Background Hand hygiene compliance has improved significantly through hand hygiene promotion programs that have included poster campaign, monitoring and performance feedback, and education with special attentions to perceived subjective norms. We investigated factors associated with improved hand hygiene compliance, focusing on whether the improvement of hand hygiene compliance is associated with changed perception toward hand hygiene among medical personnel. Materials and Methods Hand hygiene compliance and perceptions toward hand hygiene among medical personnel were compared between the second quarter of 2009 (before the start of a hand hygiene promotion program) and the second quarter of 2012. We assessed adherence to hand hygiene among medical personnel quarterly according to the WHO recommended method for direct observation. Also, we used a modified self-report questionnaire to collect perception data. Results Hand hygiene compliance among physicians and nurses improved significantly from 19.0% in 2009 to 74.5% in 2012 (P Hand hygiene compliance among the medical personnel continued to improve, with a slight decline in 2013. Perceptions toward hand hygiene improved significantly between 2009 and 2012. Specifically, improvements were evident in intention to adhere to hand hygiene, knowledge about hand hygiene methods, knowledge about hand hygiene indications including care of a dirty and a clean body site on the same patient, perceived behavioral and subjective norms, positive attitude toward hand hygiene promotion campaign, perception of difficulty in adhering to hand hygiene, and motivation to improve adherence to hand hygiene. Conclusions The examined hand hygiene promotion program resulted in improved hand hygiene compliance and perception toward hand hygiene among medical personnel. The improved perception increased hand hygiene compliance. Especially, the perception of being a role model for other colleagues is very important to improve hand hygiene

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... intended to promote or encourage adherence to CDC hand hygiene recommendations. It is a component of the Clean ... also aims to address myths and misperceptions about hand hygiene and empower patients to play a role in ...

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,760 ... 536,963 views 1:46 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,574 views ...

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ... 089,212 views 4:50 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 26,032 views ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,404 ... 081,511 views 4:50 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,194 views ...

  8. Clean Hands Count

    Medline Plus

    Full Text Available ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ... 086,746 views 4:50 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,802 views ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... 453 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ... 28,656 views 3:40 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 26,480 views ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... 024 views 2:58 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,404 ... 2,805 views 3:13 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,574 views ...

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... 362 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 412,404 ... 219,427 views 1:27 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 25,194 views ...

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ... 28,656 views 3:40 Hand hygiene FULL music video - Duration: 2:33. AlfredHealthTV 26,032 views ...

  13. Identification of Object Dynamics Using Hand Worn Motion and Force Sensors

    Directory of Open Access Journals (Sweden)

    Henk G. Kortier

    2016-11-01

    Full Text Available Emerging microelectromechanical system (MEMS-based sensors become much more applicable for on-body measurement purposes lately. Especially, the development of a finger tip-sized tri-axial force sensor gives the opportunity to measure interaction forces between the human hand and environmental objects. We have developed a new prototype device that allows simultaneous 3D force and movement measurements at the finger and thumb tips. The combination of interaction forces and movements makes it possible to identify the dynamical characteristics of the object being handled by the hand. With this device attached to the hand, a subject manipulated mass and spring objects under varying conditions. We were able to identify and estimate the weight of two physical mass objects (0.44 kg: 29 . 3 % ± 18 . 9 % and 0.28 kg: 19 . 7 % ± 10 . 6 % and the spring constant of a physical spring object ( 16 . 3 % ± 12 . 6 % . The system is a first attempt to quantify the interactions of the hand with the environment and has many potential applications in rehabilitation, ergonomics and sports.

  14. The oxygen-conserving potential of the diving response: A kinetic-based analysis.

    Science.gov (United States)

    Costalat, Guillaume; Coquart, Jeremy; Castres, Ingrid; Joulia, Fabrice; Sirost, Olivier; Clua, Eric; Lemaître, Frédéric

    2017-04-01

    We investigated the oxygen-conserving potential of the human diving response by comparing trained breath-hold divers (BHDs) to non-divers (NDs) during simulated dynamic breath-holding (BH). Changes in haemodynamics [heart rate (HR), stroke volume (SV), cardiac output (CO)] and peripheral muscle oxygenation [oxyhaemoglobin ([HbO 2 ]), deoxyhaemoglobin ([HHb]), total haemoglobin ([tHb]), tissue saturation index (TSI)] and peripheral oxygen saturation (SpO 2 ) were continuously recorded during simulated dynamic BH. BHDs showed a breaking point in HR kinetics at mid-BH immediately preceding a more pronounced drop in HR (-0.86 bpm.% -1 ) while HR kinetics in NDs steadily decreased throughout BH (-0.47 bpm.% -1 ). By contrast, SV remained unchanged during BH in both groups (all P > 0.05). Near-infrared spectroscopy (NIRS) results (mean ± SD) expressed as percentage changes from the initial values showed a lower [HHb] increase for BHDs than for NDs at the cessation of BH (+24.0 ± 10.1 vs. +39.2 ± 9.6%, respectively; P kinetic-based approach we used provides further credence to the concept of an "oxygen-conserving breaking point" in the human diving response.

  15. Quantitative analysis of ibuprofen in pharmaceuticals and human control serum using kinetic spectrophotometry

    Directory of Open Access Journals (Sweden)

    SNEZANA S. MITIC

    2008-08-01

    Full Text Available The aim of this work was to develop a new kinetic spectrophoto-metric method for the determination of ibuprofen in pharmaceutical for-mulations. Ibuprofen was determined in an acidic ethanolic medium by monitoring the rate of appearance of 1-nitroso-2-naphthol, resulting from the displacement by ibuprofen of Co(III from the tris(1-nitroso-2-naptholatocobalt(III complex. The optimum operating conditions regarding reagent concentrations and temperature were established. The tangent method was adopted for constructing the calibration curve, which was found to be linear over the concentration range 0.21–1.44 and 1.44–2.06 µg ml-1. The optimized conditions yielded a theoretical detection limit of 0.03 µg ml-1 based on the 3.3 S0 criterion. The interference effects of the usual excipients of powdery drugs, foreign ions and amino acids on the reaction rate were studied in order to assess the selectivity of the method. The developed procedure was successfully applied for the rapid determination of ibuprofen in commercial pharmaceutical formulations and human control serum. The unique features of this procedure are that the determination can be performed at room temperature and the analysis time is short. The newly developed method is simple, inexpensive and efficient for use in the analysis of a large number of samples.

  16. Arthritis of the hand - Rheumatoid

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Rheumatoid Arthritis Email to a friend * required fields ...

  17. Kinetic Basis of Nucleotide Selection Employed by a Protein Template-Dependent DNA Polymerase†

    Science.gov (United States)

    Brown, Jessica A.; Fowler, Jason D.; Suo, Zucai

    2010-01-01

    Rev1, a Y-family DNA polymerase, contributes to spontaneous and DNA damage-induced mutagenic events. In this paper, we have employed pre-steady state kinetic methodology to establish a kinetic basis for nucleotide selection by human Rev1, a unique nucleotidyl transferase that uses a protein template-directed mechanism to preferentially instruct dCTP incorporation. This work demonstrated that the high incorporation efficiency of dCTP is dependent on both substrates: an incoming dCTP and a templating base dG. The extremely low base substitution fidelity of human Rev1 (100 to 10-5) was due to the preferred misincorporation of dCTP with templating bases dA, dT, and dC over correct dNTPs. Using non-natural nucleotide analogs, we showed that hydrogen bonding interactions between residue R357 of human Rev1 and an incoming dNTP are not essential for DNA synthesis. Lastly, human Rev1 discriminates between ribonucleotides and deoxyribonucleotides mainly by reducing the rate of incorporation, and the sugar selectivity of human Rev1 is sensitive to both the size and orientation of the 2′-substituent of a ribonucleotide. PMID:20518555

  18. Single DoF Hand Orthosis for Rehabilitation of Stroke and SCI Patients

    Science.gov (United States)

    Kannan Megalingam, Rajesh; Apuroop, K. G. S.; Boddupalli, Sricharan

    2017-08-01

    Many stroke and spinal cord injury patients suffer from paralysis which range from severe to nominal. Some of them, after therapy, could regain most of the motor control, particularly in hands if the severity level is not so high. In this paper we propose a hand orthosis for such patients whose stroke and spinal cord injury severity is nominal and the motor control in hands can be regained by therapy as part of their rehabilitation process. The patients can wear this orthosis and the therapy can be done with simple Human Computer Interface. The physicians, the physiotherapists and the patients themselves can carry out the therapy with the help of this device. The tests conducted in the lab and the results obtained are very promising that this can be an effective mechanism for stroke and spinal cord injury patients in their rehabilitation process. The hand orthosis is designed and fabricated locally so that it can be made available to such patients at an affordable cost.

  19. Handling the Theme of Hands in Early Modern Cross-over Contexts

    DEFF Research Database (Denmark)

    Refskou, Anne Sophie Haahr; Thomasen, Laura Søvsø

    2014-01-01

    and significances. In this article, we examine the role of the hand and two of its familiar functions –pointing and touching – against diverse and diverging understandings of human perception and cognition in the period focussing particularly on relations between bodies and minds. Through comparative analyses...

  20. P1-20: The Relation of Eye and Hand Movement during Multimodal Recall Memory

    Directory of Open Access Journals (Sweden)

    Eun-Sol Kim

    2012-10-01

    Full Text Available Eye and hand movement tracking has been proven to be a successful tool and is widely used to figure out characteristics of human cognition in language or visual processing (Just & Carpenter, 1976 Cognitive Psychology 8441–480. Eye movement has proven to be a successful measure to figure out characteristics of human language and visual processing (Rayner, 1998 Psychological Bulletin 124(3 372–422. Recently, mouse tracking was used for social-cognition-like categorization of sex-atypical faces and studying spoken-language processes (Magnuson, 2005 PNAS 102(28 9995–9996; Spivey et al., 2005 PNAS 102 10393–10398. Here, we present a framework that uses both eye gaze and hand movement simultaneously for analyzing the relation of them during memory retrieval. We tracked eye and mouse movements when the subject was watching a drama and playing a multimodal memory game (MMG, a cognitive task designed to investigate the recall memory mechanisms in watching video dramas (Zhang, 2009 AAAI 2009 Spring Symposium: Agents that Learn from Human Teachers 144–149. Experimental results show that eye tracking and mouse tracking provide complementary information about underlying cognitive processes. Also, we found some interesting patterns in eye-hand movement during multimodal memory recall.

  1. Space Suit Glove Pressure Garment Metacarpal Joint and Robotic Hand Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Spacesuit glove pressure garments have been a design challenge for NASA since the inception of spacesuits. The human hand demands a complex range of motions, a close...

  2. A kinetic model for impact/sliding wear of pressurized water reactor internal components. Application to rod cluster control assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Zbinden, M; Durbec, V

    1996-12-01

    A new concept of industrial wear model adapted to components of nuclear plants is proposed. Its originality is to be supported, on one hand, by experimental results obtained via wear machines of relatively short operational times, and, on the other hand, by the information obtained from the operating feedback over real wear kinetics of the reactors components. The proposed model is illustrated by an example which corresponds to a specific real situation. The determination of the coefficients permitting to cover all assembly of configurations and the validation of the model in these configurations have been the object of the most recent work. (author). 34 refs.

  3. Thermodynamic and kinetic studies of As2O3 toxicological effects on human insulin in generation diabetes mellitus

    Science.gov (United States)

    Mohsennia, Mohsen; Motaharinejad, Atieh; Rafiee-Pour, Hossain-Ali; Torabbeigi, Marzieh

    2017-12-01

    The interaction of arsenic trioxide with human insulin was investigated by circular dichroism (CD), cyclic voltammetry and electrophoresis techniques. The interfacial behavior of insulin in presence of As2O3 onto the Ag electrode surface was studied at 310 K in phosphate buffer solution (PBS). According to Far-UV CD spectroscopy results, As2O3 caused to decrease in structural compactness and variety of alpha helix into beta structures. Near-UV CD indicated that As2O3 dissociates disulfide linkage in insulin structure. The kinetic parameters, including charge-transfer coefficient and apparent heterogeneous electron transfer rate constant were also determined. The thermodynamic parameters of insulin denaturation in presence of arsenic trioxide were calculated and reported. The obtained results indicated strong adsorption of insulin in presence of arsenic trioxide onto the Ag surface via chemisorptions.

  4. Computerized measures of finger tapping: effects of hand dominance, age, and sex.

    Science.gov (United States)

    Hubel, Kerry A; Reed, Bruce; Yund, E William; Herron, Timothy J; Woods, David L

    2013-06-01

    Computerized measures of digit tapping rate were obtained over 3 successive, 10-sec. periods in the right and left index fingers, from a community sample of 1,519 participants (ages 18 to 65 years; 607 men, 912 women). Differences between the dominant and non-dominant hands were found for tapping rate, movement initiation, and button down times, and the decline in tapping rate over the successive, 10-sec. periods. Declines were found in tapping rate in older participants in association with increased intertap variability. Men had higher tapping rates than women in all age ranges. The computerized finger tapping test is an efficient and precise measure of tapping speed and kinetics of potential utility in research and clinical studies of motor performance.

  5. A new method to characterize the kinetics of cholinesterases inhibited by carbamates.

    Science.gov (United States)

    Xiao, Qiaoling; Zhou, Huimin; Wei, Hong; Du, Huaqiao; Tan, Wen; Zhan, Yiyi; Pistolozzi, Marco

    2017-09-10

    The inhibition of cholinesterases (ChEs) by carbamates includes a carbamylation (inhibition) step, in which the drug transfers its carbamate moiety to the active site of the enzyme and a decarbamylation (activity recovery) step, in which the carbamyl group is hydrolyzed from the enzyme. The carbamylation and decarbamylation kinetics decide the extent and the duration of the inhibition, thus the full characterization of candidate carbamate inhibitors requires the measurement of the kinetic constants describing both steps. Carbamylation and decarbamylation rate constants are traditionally measured by two separate set of experiments, thus making the full characterization of candidate inhibitors time-consuming. In this communication we show that by the analysis of the area under the inhibition-time curve of cholinesterases inhibited by carbamates it is possible to calculate the decarbamylation rate constant from the same data traditionally used to characterize only the carbamylation kinetics, therefore it is possible to obtain a full characterization of the inhibition with a single set of experiments. The characterization of the inhibition kinetics of human and dog plasma butyrylcholinesterase and of human acetylcholinesterase by bambuterol and bambuterol monocarbamate enantiomers was used to demonstrate the validity of the approach. The results showed that the proposed method provides reliable estimations of carbamylation and decarbamylation rate constants thus representing a simple and useful approach to reduce the time required for the characterization of carbamate inhibitors. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. The Automatic Annotation of the Semiotic Type of Hand Gestures in Obama’s Humorous Speeches

    DEFF Research Database (Denmark)

    Navarretta, Costanza

    2018-01-01

    is expressed by speech or by adding new information to what is uttered. The automatic classification of the semiotic type of gestures from their shape description can contribute to their interpretation in human-human communication and in advanced multimodal interactive systems. We annotated and analysed hand...

  7. Kinetics of phase transformations

    International Nuclear Information System (INIS)

    Thompson, M.O.; Aziz, M.J.; Stephenson, G.B.

    1992-01-01

    This volume contains papers presented at the Materials Research Society symposium on Kinetics of Phase Transformations held in Boston, Massachusetts from November 26-29, 1990. The symposium provided a forum for research results in an exceptionally broad and interdisciplinary field. Presentations covered nearly every major class of transformations including solid-solid, liquid-solid, transport phenomena and kinetics modeling. Papers involving amorphous Si, a dominant topic at the symposium, are collected in the first section followed by sections on four major areas of transformation kinetics. The symposium opened with joint sessions on ion and electron beam induced transformations in conjunction with the Surface Chemistry and Beam-Solid Interactions: symposium. Subsequent sessions focused on the areas of ordering and nonlinear diffusion kinetics, solid state reactions and amorphization, kinetics and defects of amorphous silicon, and kinetics of melting and solidification. Seven internationally recognized invited speakers reviewed many of the important problems and recent results in these areas, including defects in amorphous Si, crystal to glass transformations, ordering kinetics, solid-state amorphization, computer modeling, and liquid/solid transformations

  8. Positron kinetics in an idealized PET environment

    Science.gov (United States)

    Robson, R. E.; Brunger, M. J.; Buckman, S. J.; Garcia, G.; Petrović, Z. Lj.; White, R. D.

    2015-08-01

    The kinetic theory of non-relativistic positrons in an idealized positron emission tomography PET environment is developed by solving the Boltzmann equation, allowing for coherent and incoherent elastic, inelastic, ionizing and annihilating collisions through positronium formation. An analytic expression is obtained for the positronium formation rate, as a function of distance from a spherical source, in terms of the solutions of the general kinetic eigenvalue problem. Numerical estimates of the positron range - a fundamental limitation on the accuracy of PET, are given for positrons in a model of liquid water, a surrogate for human tissue. Comparisons are made with the ‘gas-phase’ assumption used in current models in which coherent scattering is suppressed. Our results show that this assumption leads to an error of the order of a factor of approximately 2, emphasizing the need to accurately account for the structure of the medium in PET simulations.

  9. Hand Pose Estimation by Fusion of Inertial and Magnetic Sensing Aided by a Permanent Magnet.

    Science.gov (United States)

    Kortier, Henk G; Antonsson, Jacob; Schepers, H Martin; Gustafsson, Fredrik; Veltink, Peter H

    2015-09-01

    Tracking human body motions using inertial sensors has become a well-accepted method in ambulatory applications since the subject is not confined to a lab-bounded volume. However, a major drawback is the inability to estimate relative body positions over time because inertial sensor information only allows position tracking through strapdown integration, but does not provide any information about relative positions. In addition, strapdown integration inherently results in drift of the estimated position over time. We propose a novel method in which a permanent magnet combined with 3-D magnetometers and 3-D inertial sensors are used to estimate the global trunk orientation and relative pose of the hand with respect to the trunk. An Extended Kalman Filter is presented to fuse estimates obtained from inertial sensors with magnetic updates such that the position and orientation between the human hand and trunk as well as the global trunk orientation can be estimated robustly. This has been demonstrated in multiple experiments in which various hand tasks were performed. The most complex task in which simultaneous movements of both trunk and hand were performed resulted in an average rms position difference with an optical reference system of 19.7±2.2 mm whereas the relative trunk-hand and global trunk orientation error was 2.3±0.9 and 8.6±8.7 deg respectively.

  10. Modelling and determination of the kinetic parameters of the pyrolysis of Dichrostachys cinerea

    International Nuclear Information System (INIS)

    Abreu Naranjo, Reinier; Romero Romero, Osvaldo

    2011-01-01

    In the present study were analyzed biomass samples of Dichrostachys cinerea, commonly known in Cuba as marabou, by thermogravimetric method at various heating rates of devolatilization in nitrogen atmosphere at 5, 10 and 20 C min-1. On the kinetic analysis was used a mechanism of three independent reactions of order 1, generally attributed to three chief components of this kind of lignocellulose materials, hemicelluloses, cellulose and lignin. The values of activation energy, pre-exponential factor and contribution factor were similar to those reported in previous research for this type of biomass. The proposed model predicts with acceptable correlation the experimental and calculated curves of the decomposition of D. cinerea, with a deviation factor less than 5% for the temperature range studied. On the other hand, the kinetic parameters of the thermal decomposition coupled at equations of transport phenomena are essential to optimize the design and use of biomass thermochemical conversion processes, hence the importance of the research. (author)

  11. Radiation Induced G2 Chromatic Break and Repairs Kinetics in Human Lymphoblastoid Cells

    International Nuclear Information System (INIS)

    Seong, Jin Sil

    1993-01-01

    In understanding radiosensitivity a new concept of inherent radiosensitivity based on individuality and heterogeneity within a population has recently beer explored. There has been some discussion of possible mechanism underlying differences in radiosensitivity between cells. Ataxia telangiectasia(AT), a rare autosomal recessive genetic disorder, is characterized by hypersensitivity to lonizing radiation and other DNA damaging agents at the cellular level. There have been a lot of efforts to describe the cause of this hypersensitivity to radiation. At the cellular level, chromosome repair kinetics study would be an appropriate approach. The purpose of this study was to better understand radiosensitivity in an approach to investigate kinetics of induction and repair of G2 chromatic breaks using normal, AT heterozygous(ATH), and AT homozygous lymphoblastoid cell lines. In an attempt to estimate initial damage, 9-β-D-arabinosyl-2-fluoroadenine, an inhibitor of DNA synthesis and repair, was used in this study. It was found from this study that radiation induces higher chromatid breaks in AT than in normal and ATH cells. There was no significant differences of initial chromatid breaks between normal and ATH cells. Repair kinetics was the same for all. So the higher level of breaks in AT G2 cells is thought to be a reflection of the increased initial damage. The amount of initial damage correlated well with survival fraction at 2 Gy of cell survival curve following radiation. Therefore, the difference of radiosensitivity in terms of G2 chromosomal sensitivity is thought to result from the difference of initial damage

  12. Effect on growth and cell cycle kinetics of estradiol and tamoxifen on MCF-7 human breast cancer cells grown in vitro and in nude mice

    DEFF Research Database (Denmark)

    Brünner, N; Bronzert, D; Vindeløv, L L

    1989-01-01

    The effects of estradiol and tamoxifen (TAM) on the estrogen-dependent human breast cancer cell line MCF-7 grown in vitro and in nude mice were compared. The effect on growth was determined by cell number in vitro and by tumor growth curves in nude mice. The effects on the cell cycle kinetics were...... determined by repeated flow cytometric DNA analyses in vitro and in vivo and by the technique of labeled mitosis in nude mouse-grown tumors. Under in vitro conditions, estradiol induced a pronounced increase in S-phase fraction and cell number. TAM inhibited growth of MCF-7 cells with a concomitant increase...... in the G1 phase from 60% to 75%. In nude mice, MCF-7 only formed tumors in estradiol-supplemented mice. No differences were observed in growth and cell kinetics between 0.1 and 1.0 mg of estradiol. Daily i.p. injections of TAM resulted in tumor growth inhibition with shrinkage of tumors. The flow...

  13. The ability of AIF-1 to activate human vascular smooth muscle cells is lost by mutations in the EF-hand calcium-binding region

    International Nuclear Information System (INIS)

    Autieri, Michael V.; Chen Xing

    2005-01-01

    Allograft Inflammatory Factor-1 (AIF-1) is a cytoplasmic calcium-binding protein expressed in vascular smooth muscle cells (VSMC) in response to injury or cytokine stimulation. AIF-1 contains a partially conserved EF-hand calcium-binding domain, and participates in VSMC activation by activation of Rac1 and induction of Granulocyte-Colony Stimulating Factor (G-CSF) expression; however, the mechanism whereby AIF-1 mediates these effects is presently uncharacterized. To determine if calcium binding plays a functional role in AIF-1 activity, a single site-specific mutation was made in the EF-hand calcium-binding domain to abrogate binding of calcium (AIF-1ΔA), which was confirmed by calcium overlay. Functionally, similar to wild-type AIF-1, AIF-1ΔA was able to polymerize F-actin in vitro. However, in contrast to wild-type AIF-1, over-expression of AIF-1ΔA was unable to increase migration or proliferation of primary human VSMC. Further, it was unable to activate Rac1, or induce G-CSF expression to the degree as wild-type AIF-1. Taken together, modification of the wild-type EF-hand domain and native calcium-binding activity results in a loss of AIF-1 function. We conclude that appropriate calcium-binding potential is critical in AIF-1-mediated effects on VSMC pathophysiology, and that AIF-1 activity is mediated by Rac1 activation and G-CSF expression

  14. A resource facility for kinetic analysis: modeling using the SAAM computer programs.

    Science.gov (United States)

    Foster, D M; Boston, R C; Jacquez, J A; Zech, L

    1989-01-01

    Kinetic analysis and integrated system modeling have contributed significantly to understanding the physiology and pathophysiology of metabolic systems in humans and animals. Many experimental biologists are aware of the usefulness of these techniques and recognize that kinetic modeling requires special expertise. The Resource Facility for Kinetic Analysis (RFKA) provides this expertise through: (1) development and application of modeling technology for biomedical problems, and (2) development of computer-based kinetic modeling methodologies concentrating on the computer program Simulation, Analysis, and Modeling (SAAM) and its conversational version, CONversational SAAM (CONSAM). The RFKA offers consultation to the biomedical community in the use of modeling to analyze kinetic data and trains individuals in using this technology for biomedical research. Early versions of SAAM were widely applied in solving dosimetry problems; many users, however, are not familiar with recent improvements to the software. The purpose of this paper is to acquaint biomedical researchers in the dosimetry field with RFKA, which, together with the joint National Cancer Institute-National Heart, Lung and Blood Institute project, is overseeing SAAM development and applications. In addition, RFKA provides many service activities to the SAAM user community that are relevant to solving dosimetry problems.

  15. Human engineering

    International Nuclear Information System (INIS)

    Yang, Seong Hwan; Park, Bum; Gang, Yeong Sik; Gal, Won Mo; Baek, Seung Ryeol; Choe, Jeong Hwa; Kim, Dae Sung

    2006-07-01

    This book mentions human engineering, which deals with introduction of human engineering, Man-Machine system like system design, and analysis and evaluation of Man-Machine system, data processing and data input, display, system control of man, human mistake and reliability, human measurement and design of working place, human working, hand tool and manual material handling, condition of working circumstance, working management, working analysis, motion analysis working measurement, and working improvement and design in human engineering.

  16. Relationship Between Hand Contact Angle and Shoulder Loading During Manual Wheelchair Propulsion by Individuals with Paraplegia.

    Science.gov (United States)

    Requejo, Philip Santos; Mulroy, Sara J; Ruparel, Puja; Hatchett, Patricia E; Haubert, Lisa Lighthall; Eberly, Valerie J; Gronley, JoAnne K

    2015-01-01

    Shoulder loading during manual wheelchair propulsion (WCP) contributes to the development of shoulder pain in individuals with spinal cord injury (SCI). To use regression analysis to investigate the relationships between the hand contact angle (location of the hand on the pushrim at initial contact and release during the push phase of the WCP cycle) with propulsion characteristics, pushrim forces, and shoulder kinetics during WCP in individuals with paraplegia. Biomechanical data were collected from 222 individuals (198 men and 24 women) with paraplegia from SCI during WCP on a stationary ergometer at a self-selected speed. The average age of participants was 34.7 years (±9.3), mean time since SCI was 9.3 years (±6.1), and average body weight was 74.4 kg (±15.9). The majority (n = 127; 56%) of participants had lower level paraplegia (T8 to L5) and 95 (42%) had high paraplegia (T2 to T7). Increased push arc (mean = 75.3°) was associated with greater velocity (R = 0.384, P contact angle and hand release angles were equally associated with cycle distance and cadence, whereas a more anterior release angle was associated with greater velocity (R = 0.372, P contact angle was associated with greater posterior shoulder net joint force (R = 0.229, P = .001) and greater flexor net joint moment (R = 0.204, P = .002), whereas a more anterior hand release angle was significantly associated with increased vertical (R = 0.270, P contact and hand release must be considered in WCP training. It is recommended that participants should reach back to initiate contact with the pushrim to maximize push arc but avoid a more anterior hand position at release, because this could increase shoulder load during the push phase of WCP.

  17. Ambulatory assessment of human body kinematics and kinetics

    NARCIS (Netherlands)

    Schepers, H. Martin

    2009-01-01

    Traditional human movement analysis systems consist of an optical position measurement system with one or more 6D force plates mounted in a laboratory. Although clinically accepted as `the golden standard' for the assessment of human movement, the restriction to a laboratory environment with its

  18. Mind the hand

    DEFF Research Database (Denmark)

    Davidsen, Jacob; Christiansen, Ellen Tove

    2014-01-01

    Apart from touching the screen, what is the role of the hands for children collaborating around touchscreens? Based on embodied and multimodal interaction analysis of 8- and 9-year old pairs collaborating around touchscreens, we conclude that children use their hands to constrain and control acce...

  19. Verbal Prompting, Hand-over-Hand Instruction, and Passive Observation in Teaching Children with Developmental Disabilities.

    Science.gov (United States)

    Biederman, G. B.; Fairhall, J. L.; Raven, K. A.; Davey, V. A.

    1998-01-01

    A study involving six children (ages 5-13) with mental retardation found that overall passive modeling was significantly more effective than hand-over-hand modeling in teaching skills, and that passive modeling was significantly more effective than hand-over-hand modeling with response-contingent verbal prompting. (Author/CR)

  20. Kinetics in radiation chemistry

    International Nuclear Information System (INIS)

    Hummel, A.

    1987-01-01

    In this chapter the authors first briefly review the kinetics of first- and second-order processes for continuous and pulsed irradiation, without taking the effects of nonhomogeneous formation of the species into consideration. They also discuss diffusion controlled reactions under conditions where interactions of more than two particles can be neglected, first the kinetics of the diffusion-controlled reaction of randomly generated species (homogeneous reaction) and then that of isolated pairs of reactants. The latter is often called geminate kinetics when dealing with pairs of oppositely charged species; they shall use this term for the kinetics of isolated pairs in general. In the last section they discuss briefly the kinetics of groups of more than two reactants