WorldWideScience

Sample records for human eye eye

  1. Preference for human eyes in human infants.

    Science.gov (United States)

    Dupierrix, Eve; de Boisferon, Anne Hillairet; Méary, David; Lee, Kang; Quinn, Paul C; Di Giorgio, Elisa; Simion, Francesca; Tomonaga, Masaki; Pascalis, Olivier

    2014-07-01

    Despite evidence supporting an early attraction to human faces, the nature of the face representation in neonates and its development during the first year after birth remain poorly understood. One suggestion is that an early preference for human faces reflects an attraction toward human eyes because human eyes are distinctive compared with other animals. In accord with this proposal, prior empirical studies have demonstrated the importance of the eye region in face processing in adults and infants. However, an attraction for the human eye has never been shown directly in infants. The current study aimed to investigate whether an attraction for human eyes would be present in newborns and older infants. With the use of a preferential looking time paradigm, newborns and 3-, 6-, 9-, and 12-month-olds were simultaneously presented with a pair of nonhuman primate faces (chimpanzees and Barbary macaques) that differed only by the eyes, thereby pairing a face with original nonhuman primate eyes with the same face in which the eyes were replaced by human eyes. Our results revealed that no preference was observed in newborns, but a preference for nonhuman primate faces with human eyes emerged from 3months of age and remained stable thereafter. The findings are discussed in terms of how a preference for human eyes may emerge during the first few months after birth.

  2. A Model of the Human Eye

    Science.gov (United States)

    Colicchia, G.; Wiesner, H.; Waltner, C.; Zollman, D.

    2008-01-01

    We describe a model of the human eye that incorporates a variable converging lens. The model can be easily constructed by students with low-cost materials. It shows in a comprehensible way the functionality of the eye's optical system. Images of near and far objects can be focused. Also, the defects of near and farsighted eyes can be demonstrated.

  3. Dry Eye

    Science.gov (United States)

    ... Eye > Facts About Dry Eye Facts About Dry Eye This information was developed by the National Eye ... the best person to answer specific questions. Dry Eye Defined What is dry eye? Dry eye occurs ...

  4. Eye Allergies

    Science.gov (United States)

    ... Español Eye Health / Eye Health A-Z Eye Allergies Sections What Are Eye Allergies? Eye Allergy Symptoms ... allergy diagnosis Eye allergy treatment What Are Eye Allergies? Written by: David Turbert Reviewed by: Brenda Pagan- ...

  5. Eye redness

    Science.gov (United States)

    Bloodshot eyes; Red eyes; Scleral injection; Conjunctival injection ... There are many causes of a red eye or eyes. Some are medical emergencies. Others are a cause for concern, but not an emergency. Many are nothing to worry about. Eye ...

  6. Cyclooxygenase-2 expression in the normal human eye and its expression pattern in selected eye tumours

    DEFF Research Database (Denmark)

    Wang, Jinmei; Wu, Yazhen; Heegaard, Steffen;

    2011-01-01

    using antibodies against COX-2 was performed on paraffin sections of normal human eyes and selected eye tumours arising from cells expressing COX-2. Results: Cyclooxygenase-2 expression was found in various structures of the normal eye. Abundant expression was seen in the cornea, iris, ciliary body......Purpose: Cyclooxygenase-2 (COX-2) is an enzyme involved in neoplastic processes. The purpose of the present study is to investigate COX-2 expression in the normal human eye and the expression pattern in selected eye tumours involving COX-2 expressing cells. Methods: Immunohistochemical staining...... and retina. The COX-2 expression was less in tumours deriving from the ciliary epithelium and also in retinoblastoma. Conclusion: Cyclooxygenase-2 is constitutively expressed in normal human eyes. The expression of COX-2 is much lower in selected eye tumours involving COX-2 expressing cells....

  7. Human-eye versus computerized color matching.

    Science.gov (United States)

    Yap, A U; Sim, C P; Loh, W L; Teo, J H

    1999-01-01

    This project compared the difference in color matching between human-eye assessment and computerized colorimetry. Fifty dental personnel were asked to color match Vita Lumin shade tabs to seven different randomly arranged test tabs from the Z100 shade guide. All evaluators were blinded to the shades of the test tabs and were asked to match only body shade of the Vita Lumin tab to the middle third or body of each test tab. The results obtained were subsequently computed into L*a*b* values and compared with results obtained by computerized colorimetry. Results indicate that the difference in color matching between human-eye assessment and computerized colorimetry is shade dependent. Discrepancy was significant for b* coordinates for shades A1 and B2 and L* and b* coordinates for shade C4. For all shades evaluated, color difference between human-eye and computerized color matching is perceivable under clinical settings, as delta E values are greater than 3. There is a need for correction factors in the formal specification of the color-matching software due to the discrepancy between human-eye and computerized colorimetric color matching.

  8. Healthy Eyes

    Science.gov (United States)

    ... los Ojos Cómo hablarle a su oculista Healthy Eyes Having a comprehensive dilated eye exam is one ... or contact lenses. What is a comprehensive dilated eye exam? A comprehensive dilated eye exam is a ...

  9. Zoonotic helminths affecting the human eye

    Directory of Open Access Journals (Sweden)

    Eberhard Mark L

    2011-03-01

    Full Text Available Abstract Nowaday, zoonoses are an important cause of human parasitic diseases worldwide and a major threat to the socio-economic development, mainly in developing countries. Importantly, zoonotic helminths that affect human eyes (HIE may cause blindness with severe socio-economic consequences to human communities. These infections include nematodes, cestodes and trematodes, which may be transmitted by vectors (dirofilariasis, onchocerciasis, thelaziasis, food consumption (sparganosis, trichinellosis and those acquired indirectly from the environment (ascariasis, echinococcosis, fascioliasis. Adult and/or larval stages of HIE may localize into human ocular tissues externally (i.e., lachrymal glands, eyelids, conjunctival sacs or into the ocular globe (i.e., intravitreous retina, anterior and or posterior chamber causing symptoms due to the parasitic localization in the eyes or to the immune reaction they elicit in the host. Unfortunately, data on HIE are scant and mostly limited to case reports from different countries. The biology and epidemiology of the most frequently reported HIE are discussed as well as clinical description of the diseases, diagnostic considerations and video clips on their presentation and surgical treatment. Homines amplius oculis, quam auribus credunt Seneca Ep 6,5 Men believe their eyes more than their ears

  10. Multi-View Algorithm for Face, Eyes and Eye State Detection in Human Image- Study Paper

    Directory of Open Access Journals (Sweden)

    Latesh Kumari

    2014-07-01

    Full Text Available For fatigue detection such as in the application of driver‟s fatigue monitoring system, the eye state analysis is one of the important and deciding steps to determine the fatigue of driver‟s eyes. In this study, algorithms for face detection, eye detection and eye state analysis have been studied and presented as well as an efficient algorithm for detection of face, eyes have been proposed. Firstly the efficient algorithm for face detection method has been presented which find the face area in the human images. Then, novel algorithms for detection of eye region and eye state are introduced. In this paper we propose a multi-view based eye state detection to determine the state of the eye. With the help of skin color model, the algorithm detects the face regions in an YCbCr color model. By applying the skin segmentation which normally separates the skin and non-skin pixels of the images, it detects the face regions of the image under various lighting and noise conditions. Then from these face regions, the eye regions are extracted within those extracted face regions. Our proposed algorithms are fast and robust as there is not pattern match.

  11. Human secretory phospholipase A(2), group IB in normal eyes and in eye diseases

    DEFF Research Database (Denmark)

    Prause, Jan U; Bazan, Nicolas G; Heegaard, Steffen

    2007-01-01

    study was to identify human GIB (hGIB) in the normal human eye and investigate the pattern of expression in patients with eye diseases involving hGIB-rich cells. METHODS: Human GIB mRNA was identified in the human retina by means of in situ hybridization and polymerase chain reaction. Antibodies against...... hGIB were obtained and immunohistochemical staining was performed on paraffin-embedded sections of normal and pathological eyes. Donor eyes from patients with descemetization of the cornea, Fuchs' corneal endothelial dystrophy, age-related macular degeneration, malignant choroidal melanoma......, retinitis pigmentosa and glaucoma were evaluated. RESULTS: Expression of hGIB was found in various cells of the eye. The most abundant expression was found in retinal pigment epithelium (RPE) cells, the inner photoreceptor segments, ganglion cells and the corneal endothelium. We explored diseases involving...

  12. Cyclooxygenase-2 expression in the normal human eye and its expression pattern in selected eye tumours

    DEFF Research Database (Denmark)

    Wang, Jinmei; Wu, Yazhen; Heegaard, Steffen;

    2011-01-01

    and retina. The COX-2 expression was less in tumours deriving from the ciliary epithelium and also in retinoblastoma. Conclusion: Cyclooxygenase-2 is constitutively expressed in normal human eyes. The expression of COX-2 is much lower in selected eye tumours involving COX-2 expressing cells....

  13. People deliver eye care: managing human resources

    Directory of Open Access Journals (Sweden)

    Kayode Odusote

    2005-12-01

    Full Text Available People deliver health. Effective health care needs an efficient and motivated health workforce, which is the totality of individuals who directly or indirectly contribute to the promotion, protection and improvement of the health of the population.Community eye health is about providing eye health care to the people as close as possible to where they live and as much as possible at a price they can afford. It promotes people-centred care rather than the traditional disease-centred eye care services. In order to provide effective and efficient eye care services, we need an adequate number of well-qualified, well-motivated and equitably distributed eye health workers (EHWs.

  14. Eye Injuries

    Science.gov (United States)

    The structure of your face helps protect your eyes from injury. Still, injuries can damage your eye, sometimes severely enough that you could lose your vision. Most eye injuries are preventable. If you play sports or ...

  15. Eye Wear

    Science.gov (United States)

    Eye wear protects or corrects your vision. Examples are Sunglasses Safety goggles Glasses (also called eyeglasses) Contact ... jobs and some sports carry a risk of eye injury. Thousands of children and adults get eye ...

  16. Eye Cancer

    Science.gov (United States)

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... adults are melanoma and lymphoma. The most common eye cancer in children is retinoblastoma, which starts in ...

  17. Eye Diseases

    Science.gov (United States)

    ... the back of the eye Macular degeneration - a disease that destroys sharp, central vision Diabetic eye problems ... defense is to have regular checkups, because eye diseases do not always have symptoms. Early detection and ...

  18. A real-life illusion of assimilation in the human face: eye size illusion caused by eyebrows and eye shadow.

    Science.gov (United States)

    Morikawa, Kazunori; Matsushita, Soyogu; Tomita, Akitoshi; Yamanami, Haruna

    2015-01-01

    Does an assimilative illusion like the Delboeuf illusion occur in the human face? We investigated factors that might influence the perceived size of the eyes in a realistic face. Experiment 1 manipulated the position of the eyebrows (high or low), the presence/absence of eye shadow, and the viewing distance (0.6 m or 5 m), then measured the perceived eye size using a psychophysical method. The results showed that low eyebrows (i.e., closer to the eyes) make the eyes appear larger, suggesting that the assimilation of eyes into the eyebrows is stronger when the eye-eyebrow distance is shorter. The results also demonstrated that the application of eye shadow also makes the eyes look larger. Moreover, the effect of eye shadow is more pronounced when viewed from a distance. In order to investigate the mechanism of the eye size illusion demonstrated in Experiment 1, Experiment 2 measured the magnitude of the Delboeuf illusion at a viewing distance of 0.6 m or 5 m, with or without gray gradation simulating the eye shadow that was used in Experiment 1. The experiment demonstrated that the Delboeuf illusion is modulated by viewing distance and gradation in the same way as the eye size illusion. These results suggest that the eye size illusion induced by the eyebrows and the Delboeuf illusion involve the same mechanism, and that eye shadow causes the assimilation of the eyes into itself and enhances assimilation between the eyes and the eyebrows.

  19. Modeling and simulation of the human eye

    Science.gov (United States)

    Duran, R.; Ventura, L.; Nonato, L.; Bruno, O.

    2007-02-01

    The computational modeling of the human eye has been wide studied for different sectors of the scientific and technological community. One of the main reasons for this increasing interest is the possibility to reproduce eye optic properties by means of computational simulations, becoming possible the development of efficient devices to treat and to correct the problems of the vision. This work explores this aspect still little investigated of the modeling of the visual system, considering a computational sketch that make possible the use of real data in the modeling and simulation of the human visual system. This new approach makes possible the individual inquiry of the optic system, assisting in the construction of new techniques used to infer vital data in medical investigations. Using corneal topography to collect real data from patients, a computational model of cornea is constructed and a set of simulations were build to ensure the correctness of the system and to investigate the effect of corneal abnormalities in retinal image formation, such as Plcido Discs, Point Spread Function, Wave front and the projection of a real image and it's visualization on retina.

  20. A novel algorithm for automatic localization of human eyes

    Institute of Scientific and Technical Information of China (English)

    Liang Tao (陶亮); Juanjuan Gu (顾涓涓); Zhenquan Zhuang (庄镇泉)

    2003-01-01

    Based on geometrical facial features and image segmentation, we present a novel algorithm for automatic localization of human eyes in grayscale or color still images with complex background. Firstly, a determination criterion of eye location is established by the prior knowledge of geometrical facial features. Secondly,a range of threshold values that would separate eye blocks from others in a segmented face image (I.e.,a binary image) are estimated. Thirdly, with the progressive increase of the threshold by an appropriate step in that range, once two eye blocks appear from the segmented image, they will be detected by the determination criterion of eye location. Finally, the 2D correlation coefficient is used as a symmetry similarity measure to check the factuality of the two detected eyes. To avoid the background interference, skin color segmentation can be applied in order to enhance the accuracy of eye detection. The experimental results demonstrate the high efficiency of the algorithm and correct localization rate.

  1. EyeGENE

    Data.gov (United States)

    U.S. Department of Health & Human Services — The eyeGENE® Biorepository and corresponding Database contain family history and clinical eye exam data from subjects enrolled in eyeGENE® Program coupled to...

  2. Eye movement-invariant representations in the human visual system.

    Science.gov (United States)

    Nishimoto, Shinji; Huth, Alexander G; Bilenko, Natalia Y; Gallant, Jack L

    2017-01-01

    During natural vision, humans make frequent eye movements but perceive a stable visual world. It is therefore likely that the human visual system contains representations of the visual world that are invariant to eye movements. Here we present an experiment designed to identify visual areas that might contain eye-movement-invariant representations. We used functional MRI to record brain activity from four human subjects who watched natural movies. In one condition subjects were required to fixate steadily, and in the other they were allowed to freely make voluntary eye movements. The movies used in each condition were identical. We reasoned that the brain activity recorded in a visual area that is invariant to eye movement should be similar under fixation and free viewing conditions. In contrast, activity in a visual area that is sensitive to eye movement should differ between fixation and free viewing. We therefore measured the similarity of brain activity across repeated presentations of the same movie within the fixation condition, and separately between the fixation and free viewing conditions. The ratio of these measures was used to determine which brain areas are most likely to contain eye movement-invariant representations. We found that voxels located in early visual areas are strongly affected by eye movements, while voxels in ventral temporal areas are only weakly affected by eye movements. These results suggest that the ventral temporal visual areas contain a stable representation of the visual world that is invariant to eye movements made during natural vision.

  3. Human eye haptics-based multimedia.

    Science.gov (United States)

    Velandia, David; Uribe-Quevedo, Alvaro; Perez-Gutierrez, Byron

    2014-01-01

    Immersive and interactive multimedia applications offer complementary study tools in anatomy as users can explore 3D models while obtaining information about the organ, tissue or part being explored. Haptics increases the sense of interaction with virtual objects improving user experience in a more realistic manner. Common eye studying tools are books, illustrations, assembly models, and more recently these are being complemented with mobile apps whose 3D capabilities, computing power and customers are increasing. The goal of this project is to develop a complementary eye anatomy and pathology study tool using deformable models within a multimedia application, offering the students the opportunity for exploring the eye from up close and within with relevant information. Validation of the tool provided feedback on the potential of the development, along with suggestions on improving haptic feedback and navigation.

  4. Wide-angle chromatic aberration corrector for the human eye.

    Science.gov (United States)

    Benny, Yael; Manzanera, Silvestre; Prieto, Pedro M; Ribak, Erez N; Artal, Pablo

    2007-06-01

    The human eye is affected by large chromatic aberration. This may limit vision and makes it difficult to see fine retinal details in ophthalmoscopy. We designed and built a two-triplet system for correcting the average longitudinal chromatic aberration of the eye while keeping a reasonably wide field of view. Measurements in real eyes were conducted to examine the level and optical quality of the correction. We also performed some tests to evaluate the effect of the corrector on visual performance.

  5. Aquaporins 6-12 in the human eye

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; Holm, Lars;

    2013-01-01

    Purpose: Aquaporins (AQPs) are widely expressed and have diverse distribution patterns in the eye. AQPs 0-5 have been localized at the cellular level in human eyes. We investigated the presence of the more recently discovered AQPs 6-12 in the human eye. Methods: RT-PCR was performed on fresh tissue...... from two human eyes divided into the cornea, corneal limbus, ciliary body and iris, lens, choroid, optic nerve, retina and sclera. Each structure was examined to detect the mRNA of AQPs 6-12. Twenty-one human eyes were examined using immunohistochemical and immunofluorescence techniques to determine...... in the nonpigmented ciliary epithelium and retinal ganglion cells. AQP11 immunolabelling was detected in the corneo-limbal epithelium, nonpigmented ciliary epithelium and inner limiting membrane of the retina. Conclusion: Selective expression of AQP7, AQP9 and AQP11 was found within various structures of the human...

  6. Longitudinal chromatic aberration of the human infant eye.

    Science.gov (United States)

    Wang, Jingyun; Candy, T Rowan; Teel, Danielle F W; Jacobs, Robert J

    2008-09-01

    Although the longitudinal chromatic aberration (LCA) of the adult eye has been studied, there are no data collected from the human infant eye. A chromatic retinoscope was used to measure cyclopleged infant and adult refractions with four pseudomonochromatic sources (centered at 472, 538, 589, and 652 nm) and with polychromatic light. The LCA of the infant eyes between 472 and 652 nm was a factor of 1.7 greater than the LCA found in the adult group: infant mean=1.62 D, SD+/- 0.14 D; adult mean=0.96 D, SD+/- 0.17 D. The elevated level of LCA in infant eyes is consistent with the greater optical power of the immature eye and indicates similar chromatic dispersion in infant and adult eyes. The implications for visual performance, defocus detection, and measurement of refraction are discussed.

  7. Human eye colour and HERC2, OCA2 and MATP

    DEFF Research Database (Denmark)

    Mengel-From, Jonas; Børsting, Claus; Sanchez, Juan J.

    2010-01-01

    Prediction of human eye colour by forensic genetic methods is of great value in certain crime investigations. Strong associations between blue/brown eye colour and the SNP loci rs1129038 and rs12913832 in the HERC2 gene were recently described. Weaker associations between eye colour and other...... value of typing either the HERC2 SNPs rs1129038 and/or rs12913832 that are in strong linkage disequilibrium was observed when eye colour was divided into two groups, (1) blue, grey and green (light) and (2) brown and hazel (dark). Sequence variations in rs11636232 and rs7170852 in HERC2, rs1800407...... in OCA2 and rs16891982 in MATP showed additional association with eye colours in addition to the effect of HERC2 rs1129038. Diplotype analysis of three sequence variations in HERC2 and one sequence variation in OCA2 showed the best discrimination between light and dark eye colours with a likelihood ratio...

  8. Eye Anatomy

    Science.gov (United States)

    ... News About Us Donate In This Section Eye Anatomy en Español email Send this article to a ... You at Risk For Glaucoma? Childhood Glaucoma Eye Anatomy Five Common Glaucoma Tests Glaucoma Facts and Stats ...

  9. Eye trauma

    African Journals Online (AJOL)

    2011-02-02

    Feb 2, 2011 ... will invariably lead to lid swelling, making the examination far more difficult. ... protect the eye with a pad or shield, give tetanus prophylaxis and refer. ... A study on penetrating eye injuries in South African children found.

  10. Eye contact elicits bodily self-awareness in human adults.

    Science.gov (United States)

    Baltazar, Matias; Hazem, Nesrine; Vilarem, Emma; Beaucousin, Virginie; Picq, Jean-Luc; Conty, Laurence

    2014-10-01

    Eye contact is a typical human behaviour known to impact concurrent or subsequent cognitive processing. In particular, it has been suggested that eye contact induces self-awareness, though this has never been formally proven. Here, we show that the perception of a face with a direct gaze (that establishes eye contact), as compared to either a face with averted gaze or a mere fixation cross, led adult participants to rate more accurately the intensity of their physiological reactions induced by emotional pictures. Our data support the view that bodily self-awareness becomes more acute when one is subjected to another's gaze. Importantly, this effect was not related to a particular arousal state induced by eye contact perception. Rejecting the arousal hypothesis, we suggest that eye contact elicits a self-awareness process by enhancing self-focused attention in humans. We further discuss the implications of this proposal. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Study of Optical Models Regarding the Human Eye

    Directory of Open Access Journals (Sweden)

    Maryam Abolmasoomi

    2011-03-01

    Full Text Available Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They include models with spherical and conic-section surfaces (for cornea and lens, simple models and new models with complex surfaces. Results: Evaluation of the optical models of the eye provides the possibility of enhancing the representation of human vision and also increasing the accuracy of surgery on the anterior section of the eye to enable higher quality vision.

  12. Human eye and the sun hot and cold light

    CERN Document Server

    Vavilov, S I

    1965-01-01

    The Human Eye and the Sun, """"Hot"""" and """"Cold"""" Light is a translation from the Russian language and is a reproduction of texts from Volume IV of S.I. Vavilov, president of the U.S.S.R. Academy of Sciences. The book deals with theoretical and practical developments in lighting techniques. The text gives a brief introduction on the relationship of the human eye and the sun, describing the properties of light, of the sun, and of the human eye. The book describes hot (incandescence) and cold light (luminescence) as coming from different sources. These two types of light are compared. The

  13. Anatomy of the lamina cribrosa in human eyes.

    Science.gov (United States)

    Radius, R L; Gonzales, M

    1981-12-01

    Light microscopy of specimens of human eyes cut in cross section at the level of the lamina cribrosa showed variation in structural anatomy, as demonstrated previously in certain primate eyes. Connective tissue and glial cell structural elements were greater in nasal-temporal as compared with inferior and superior quadrants of the disc. This regional variation suggests a hypothesis for the specificity of early patterns of optic nerve dysfunction characteristic of glaucomatous optic neuropathy. In glaucomatous eyes, nerve head regions with relatively less structural tissue elements may yield early to detrimental effects of persistent pressure elevation.

  14. Diabetes eye exams

    Science.gov (United States)

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... if the doctor who takes care of your diabetes checks your eyes, you need an eye exam ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Written By: Kierstan Boyd Reviewed By: ... your eyes do not produce enough tears, it is called dry eye. Dry eye is also when ...

  16. Facts About Pink Eye

    Science.gov (United States)

    ... Information > Pink Eye (Conjunctivitis) > Facts About Pink Eye Facts About Pink Eye Pink eye is one of ... for preventing eye infections. Last Reviewed: November 2015 Fact Sheet Blurb The National Eye Institute (NEI) is ...

  17. Dilating Eye Drops

    Science.gov (United States)

    ... Corneal Abrasions Dilating Eye Drops Lazy eye (defined) Pink eye (defined) Retinopathy of Prematurity Strabismus Stye (defined) Vision ... Corneal Abrasions Dilating Eye Drops Lazy eye (defined) Pink eye (defined) Retinopathy of Prematurity Strabismus Stye (defined) Vision ...

  18. Your Eyes

    Science.gov (United States)

    ... eyes to see millions of colors. Helping You See It All Rods and cones process the light to give you the total picture. You're ... get cloudy, causing a cataract . A cataract prevents light from reaching the retina and makes it difficult to see. The eyes you have will be yours forever — ...

  19. Eyes - bulging

    Science.gov (United States)

    ... emotional support is important. When to Contact a Medical Professional Call your health care provider if: You have bulging eyes and the cause has not yet been diagnosed. Bulging eyes are accompanied by other symptoms. ... The provider will ask about your medical history and do a physical exam. Some questions ...

  20. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically......-score ranged from −1 to 1 (brown to blue). The software eliminated the need for user based interpretation and qualitative eye colour categories. In 94% (570) of 605 analyzed eye images, the iris region was successfully extracted and a PIE-score was calculated. A very high correlation between the PIE...... identified and extracted from high resolution digital images. DIAT was made user friendly with a graphical user interface. The software counted the number of blue and brown pixels in the iris image and calculated a Pixel Index of the Eye (PIE-score) that described the eye colour quantitatively. The PIE...

  1. Using the human eye to characterize displays

    Science.gov (United States)

    Gille, Jennifer; Larimer, James O.

    2001-06-01

    Monitor characterization has taken on new importance for non-professional users, who are not usually equipped to make photometric measurements. Our purpose was to examine some of the visual judgements used in characterization schemes that have been proposed for web users. We studied adjusting brightness to set the black level, banding effects du to digitization, and gamma estimation in the light an din the dark, and a color-matching tasks in the light, on a desktop CRT and a laptop LCD. Observers demonstrated the sensitivity of the visual system for comparative judgements in black- level adjustment, banding visibility, and gamma estimation. The results of the color-matching task were ambiguous. In the brightness adjustment task, the action of the adjustment was not as presumed; however, perceptual judgements were as expected under the actual conditions. Whenthe gamma estimates of observers were compared to photometric measurements, pro9blems with the definition of gamma were identified. Information about absolute light levels that would be important for characterizing a display, given the shortcomings of gamma in measuring apparent contrast, are not measurable by eye alone. The LCD was not studied as extensively as the CRT because of viewing-angle problems, and its transfer function did not follow a power law, rendering gamma estimation meaningless.

  2. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically ...

  3. Face and eye scanning in gorillas (Gorilla gorilla), orangutans (Pongo abelii), and humans (Homo sapiens): unique eye-viewing patterns in humans among hominids.

    Science.gov (United States)

    Kano, Fumihiro; Call, Josep; Tomonaga, Masaki

    2012-11-01

    Because the faces and eyes of primates convey a rich array of social information, the way in which primates view faces and eyes reflects species-specific strategies for facial communication. How are humans and closely related species such as great apes similar and different in their viewing patterns for faces and eyes? Following previous studies comparing chimpanzees (Pan troglodytes) with humans (Homo sapiens), this study used the eye-tracking method to directly compare the patterns of face and eye scanning by humans, gorillas (Gorilla gorilla), and orangutans (Pongo abelii). Human and ape participants freely viewed pictures of whole bodies and full faces of conspecifics and allospecifics under the same experimental conditions. All species were strikingly similar in that they viewed predominantly faces and eyes. No particular difference was identified between gorillas and orangutans, and they also did not differ from the chimpanzees tested in previous studies. However, humans were somewhat different from apes, especially with respect to prolonged eye viewing. We also examined how species-specific facial morphologies, such as the male flange of orangutans and the black-white contrast of human eyes, affected viewing patterns. Whereas the male flange of orangutans affected viewing patterns, the color contrast of human eyes did not. Humans showed prolonged eye viewing independently of the eye color of presented faces, indicating that this pattern is internally driven rather than stimulus dependent. Overall, the results show general similarities among the species and also identify unique eye-viewing patterns in humans.

  4. Genetic analyses of the human eye colours using a novel objective method for eye colour classification

    DEFF Research Database (Denmark)

    Andersen, Jeppe D.; Johansen, Peter; Harder, Stine;

    2013-01-01

    In this study, we present a new objective method for measuring the eye colour on a continuous scale that allows researchers to associate genetic markers with different shades of eye colour. With the use of the custom designed software Digital Iris Analysis Tool (DIAT), the iris was automatically...... and TYR rs1393350) on the eye colour. We evaluated the two published prediction models for eye colour (IrisPlex [1] and Snipper[2]) and compared the predictions with the PIE-scores. We found good concordance with the prediction from individuals typed as HERC2 rs12913832 G. However, both methods had...... by different studies and to perform large meta-studies that may reveal loci with small effects on the eye colour....

  5. Investigation of ultrasound axially traversing the human eye.

    Science.gov (United States)

    Chivers, R C; Round, W H; Zieniuk, J K

    1984-01-01

    A ray tracing model for ultrasonic propagation through the human eye, including the lens, has been developed on the assumptions of lossless media and non-reflecting interfaces. Measurement of the distribution of an ultrasonic beam before and after traversing specimens of human eyes in vitro, and of the velocity of ultrasound in the various dissected media, has permitted some comparison of the predictions of the model with experiment. The agreement is good although there are significant limitations involved and these are discussed. For imaging systems the effect of the eye arises largely from the lens which acts as a defocussing lens of focal length approx. 13.5 cm. Although the experiments were performed at approx. 4 MHz, the validity of the ray tracing model is largely frequency independent and will be appropriate at the higher frequencies commonly used in ophthalmology.

  6. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Written By: Kierstan Boyd Reviewed By: Brenda Pagan- ...

  7. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Español Eye Health / Eye Health A-Z Dry Eye Sections What Is Dry Eye? Dry Eye Symptoms ... Dry Eye Dry Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué Es el Ojo Seco? ...

  8. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye Symptoms Causes of Dry Eye Dry Eye Treatment What Is Dry Eye? Written By: Kierstan Boyd ... your vision. Privacy Policy Related New Dry Eye Treatment is a Tear-Jerker Jul 21, 2017 Three ...

  9. Diabetic Eye Disease

    Science.gov (United States)

    ... Other Dental Problems Diabetes & Sexual & Urologic Problems Diabetic Eye Disease What is diabetic eye disease? Diabetic eye disease is a group of ... loss can occur. How does diabetes affect my eyes? Diabetes affects your eyes when your blood glucose, ...

  10. Human volunteer study with PGME: Eye irritation during vapour exposure

    NARCIS (Netherlands)

    Emmen, H.H.; Muijser, H.; Arts, J.H.E.; Prinsen, M.K.

    2003-01-01

    The objective of this study was to establish the possible occurrence of eye irritation and subjective symptoms in human volunteers exposed to propylene glycol monomethyl ether (PGME) vapour at concentrations of 0, 100 and 150 ppm. Testing was conducted in 12 healthy male volunteers using a repeated

  11. Human volunteer study with PGME: Eye irritation during vapour exposure

    NARCIS (Netherlands)

    Emmen, H.H.; Muijser, H.; Arts, J.H.E.; Prinsen, M.K.

    2003-01-01

    The objective of this study was to establish the possible occurrence of eye irritation and subjective symptoms in human volunteers exposed to propylene glycol monomethyl ether (PGME) vapour at concentrations of 0, 100 and 150 ppm. Testing was conducted in 12 healthy male volunteers using a repeated

  12. Personal Identification by Eyes

    OpenAIRE

    Marinović, Dunja; Čoklo, Miran; Njirić, Sanja; Mužić, Vedrana

    2011-01-01

    Identification of persons through the eyes is in the field of biometrical science. Many security systems are based on biometric methods of personal identification, to determine whether a person is presenting itself truly. The human eye contains an extremely large number of individual characteristics that make it particularly suitable for the process of identifying a person. Today, the eye is considered to be one of the most reliable body parts for human identification. Systems usi...

  13. Elastic hysteresis in human eyes is age dependent value.

    Science.gov (United States)

    Ishii, Kotaro; Saito, Kei; Kameda, Toshihiro; Oshika, Tetsuro

    2012-06-19

    Background:  The elastic hysteresis phenomenon is observed when cyclic loading is applied to a viscoelastic system. The purpose of this study was to quantitatively evaluate elastic hysteresis in living human eyes against an external force. Design:  Prospective case series. Participants:  Twenty-four eyes of 24 normal human subjects (mean age: 41.5 ± 10.6 years) were recruited. Methods:  A non-contact tonometry process was recorded with a high-speed camera. Central corneal thickness (CCT), corneal thickness at 4 mm from the center, corneal curvature, and anterior chamber depth (ACD) were measured. Intraocular pressure (IOP) was also measured using Goldmann applanation tonometry (GAT) and dynamic contour tonometer (DCT). Main Outcome Measures:  Energy loss due to elastic hysteresis was calculated and graphed. Results:  The mean CCT was 552.5 ± 36.1 µm, corneal curvature was 7.84 ± 0.26 mm, and ACD was 2.83 ± 0.29 mm. The mean GAT-IOP was 14.2 ± 2.7 mmHg and DCT-IOP was 16.3 ± 3.5 mmHg. The mean energy loss due to elastic hysteresis was 3.90 × 10(-6) ± 2.49 × 10(-6) Nm. Energy loss due to elastic hysteresis correlated significantly with age (Pearson correlation coefficient = 0.596, p = 0.0016). There were no significant correlations between energy loss due to elastic hysteresis and other measurements. Conclusion:  Energy loss due to elastic hysteresis in the eyes of subjects was found to positively correlate with age, independent of anterior eye structure or IOP. Therefore, it is believed that the viscosity of the eye increases with age. © 2010 The Authors. Clinical and Experimental Ophthalmology © 2010 Royal Australian and New Zealand College of Ophthalmologists.

  14. Human eye visual hyperacuity: Controlled diffraction for image resolution improvement

    Science.gov (United States)

    Lagunas, A.; Domínguez, O.; Martinez-Conde, S.; Macknik, S. L.; Del-Río, C.

    2017-09-01

    The Human Visual System appears to be using a low number of sensors for image capturing, and furthermore, regarding the physical dimensions of cones—photoreceptors responsible for the sharp central vision—we may realize that these sensors are of a relatively small size and area. Nonetheless, the human eye is capable of resolving fine details thanks to visual hyperacuity and presents an impressive sensitivity and dynamic range when set against conventional digital cameras of similar characteristics. This article is based on the hypothesis that the human eye may be benefiting from diffraction to improve both image resolution and acquisition process. The developed method involves the introduction of a controlled diffraction pattern at an initial stage that enables the use of a limited number of sensors for capturing the image and makes possible a subsequent post-processing to improve the final image resolution.

  15. Your Eyes

    Science.gov (United States)

    ... people you know — like your grandparents — probably wear glasses. To the Brain! Think of the optic nerve as the great messenger in the back of your eye. The rods and cones of the retina change the colors and shapes you see into millions of nerve ...

  16. Eye-Hand-Mouth Coordination in the Human Newborn.

    Science.gov (United States)

    Futagi, Yasuyuki

    2017-10-01

    There have been several studies concerning rudimentary coordination of the eyes, hands, and mouth in the human newborn. The author attempted to clarify the ontogenetic significance of the coordination during the earliest period of human life through a systematic review. The neural mechanism underlying the coordination was also discussed based on the current knowledge of cognitive neuroscience. Searches were conducted on PubMed and Google Scholar from their inception through March 2017. Studies have demonstrated that the coordination is a visually guided goal-directed motor behavior with intension and emotion. Current cognitive research has proved that feeding requires a large-scale neural network extending over several cortices. The eye-hand-mouth coordination in the newborn can be regarded as a precursor of subsequent self-feeding, and the coordination is very likely mediated through the underdeveloped but essentially the same network interconnecting cortices as in the adult. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Teamwork for eye care

    Directory of Open Access Journals (Sweden)

    M Babar Qureshi

    2014-04-01

    Full Text Available Human resource development (HRD – the development of the people who deliver health care – has been identified as one of the key pillars of eye health delivery. HRD is one of the essential building blocks of the World Health Organization (WHO Global Action Plan: ‘Towards universal eye health’. The importance of HRD is also recognised beyond eye care, as can be seen in the WHO Health Systems approach.

  18. Infrared Eye: Prototype 2

    Science.gov (United States)

    2016-06-07

    within the wide field and slaved to the operator’s line of sight by means of an eye- tracking system. The images from both cameras are fused and shown...simultaneously on a high resolution CRT display unit, interfaced with the eye- tracking unit in order to optimize the human-machine interface. The IR Eye...system was flight tested using the Advanced system Research Aircraft (Bell 412 helicopter) from the Flight Research Laboratory of the National Research

  19. Human rights: eye for cultural diversity

    NARCIS (Netherlands)

    Y.M. Donders

    2012-01-01

    The relationship and interaction between international human rights law and cultural diversity is a current topic, as is shown by the recent debates in The Netherlands on, for instance, the proposed ban on wearing facial coverage, or burqas, and the proposed ban on ritual slaughter without anaesthes

  20. Prediction of human eye fixations using symmetry

    NARCIS (Netherlands)

    Kootstra, Gert; Schomaker, Lambert

    2009-01-01

    Humans are very sensitive to symmetry in visual patterns. Reaction time experiments show that symmetry is detected and recognized very rapidly. This suggests that symmetry is a highly salient feature. Existing computational models of saliency, however, have mainly focused on contrast as a measure of

  1. Why Do Eyes Water?

    Science.gov (United States)

    ... Lifesaver Kids Talk About: Coaches Why Do Eyes Water? KidsHealth > For Kids > Why Do Eyes Water? Print ... out of your nose. continue Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  2. Eye muscle repair - discharge

    Science.gov (United States)

    ... Lazy eye repair - discharge; Strabismus repair - discharge; Extraocular muscle surgery - discharge ... You or your child had eye muscle repair surgery to correct eye muscle ... term for crossed eyes is strabismus. Children most often ...

  3. Why Do Eyes Water?

    Science.gov (United States)

    ... Happens in the Operating Room? Why Do Eyes Water? KidsHealth > For Kids > Why Do Eyes Water? A ... out of your nose. continue Why Do Eyes Water? Eyes water for lots of different reasons besides ...

  4. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  5. Recommended Sports Eye Protectors

    Science.gov (United States)

    ... Financial Assistance Information Vision Screening and Eye Exams Zika Virus and Vision Eye Problems Eye Problems Amblyopia ( ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision ...

  6. Eye Safety at Home

    Science.gov (United States)

    ... Financial Assistance Information Vision Screening and Eye Exams Zika Virus and Vision Eye Problems Eye Problems Amblyopia ( ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision ...

  7. Eye Safety at Work

    Science.gov (United States)

    ... Financial Assistance Information Vision Screening and Eye Exams Zika Virus and Vision Eye Problems Eye Problems Amblyopia ( ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision ...

  8. Eye Movement Disorders

    Science.gov (United States)

    ... work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder in ... the eyes, sometimes called "dancing eyes" Some eye movement disorders are present at birth. Others develop over time ...

  9. About the Eye

    Medline Plus

    Full Text Available ... eye behind the iris that helps to focus light on the retina. It allows the eye to ... of the eye. It regulates the amount of light entering the eye through the pupil. Pupil (PYOO- ...

  10. Conjunctivitis (Pink Eye)

    Science.gov (United States)

    ... that can be embedded on web pages. Conjunctivitis (Pink Eye) One-Page Overview Pink, itchy eyes? Conjunctivitis – ... protect yourself from getting and spreading pink eye . Pink Eye: What To Do Discusses causes and treatment, ...

  11. Eye Disease Simulations

    Science.gov (United States)

    ... USAJobs Home > Eye Health Information > Eye Disease Simulations Eye Disease Simulations Age-Related Macular Degeneration Cataract Diabetic ... information page Back to top Diabetic Retinopathy Diabetic Eye Disease information page Back to top Glaucoma Glaucoma ...

  12. Eye Involvement in TSC

    Science.gov (United States)

    ... Privacy Policy Sitemap Learn Engage Donate About TSC Eyes Campbell (1905) first described the eye involvement in ... some form of eye involvement. Nonretinal and Retinal Eye Findings Facial angiofibromas may involve the eyelids of ...

  13. Eye Complications in IBD

    Science.gov (United States)

    ... Home > Resources > Eye Complications in IBD Go Back Eye Complications in IBD Email Print + Share Approximately 10% ... doctor’s attention sooner rather than later. TYPES OF EYE DISORDERS UVEITIS One of the most common eye ...

  14. Multiphoton tomography of the human eye

    Science.gov (United States)

    König, Karsten; Batista, Ana; Hager, Tobias; Seitz, Berthold

    2017-02-01

    Multiphoton tomography (MPT) is a novel label-free clinical imaging method for non-invasive tissue imaging with high spatial (300 nm) and temporal (100 ps) resolutions. In vivo optical histology can be realized due to the nonlinear excitation of endogenous fluorophores and second-harmonic generation (SHG) of collagen. Furthermore, optical metabolic imaging (OMI) is performed by two-photon autofluorescence lifetime imaging (FLIM). So far, applications of the multiphoton tomographs DermaInspect and MPTflex were limited to dermatology. Novel applications include intraoperative brain tumor imaging as well as cornea imaging. In this work we describe two-photon imaging of ex vivo human corneas unsuitable for transplantation. Furthermore, the cross-linking (CXL) process of corneal collagen based on UVA exposure and 0.1 % riboflavin was studied. The pharmacokinetics of the photosensitizer could be detected with high spatial resolution. Interestingly, an increase in the stromal autofluorescence intensity and modifications of the autofluorescence lifetimes were observed in the human corneal samples within a few days following CXL.

  15. Eye Contricks

    Directory of Open Access Journals (Sweden)

    Nicholas J Wade

    2011-06-01

    Full Text Available Pictorial images are icons as well as eye-cons: they provide distillations of objects or ideas into simpler shapes. They create the impression of representing that which cannot be presented. Even at the level of the photograph, the links between icon and object are tenuous. The dimensions of depth and motion are missing from icons, and these alone introduce all manner of potential ambiguities. The history of art can be considered as exploring the missing link between icon and object. Eye-cons can also be illusions—tricks of vision so that what is seen does not necessarily correspond to what is physically presented. Pictorial images can be spatialised or stylised; spatialised images generally share some of the projective characteristics of the object represented. Written words are also icons, but they do not resemble the objects they represent—they are stylised or conventional. Icons as stylised words and spatialised images were set in delightful opposition by René Magritte in a series of pipe paintings, and this theme is here alluded to. Most of visual science is now concerned with icons—two-dimensional displays on computer monitors. Is vision now the science of eye-cons?

  16. Perception of eye positions

    NARCIS (Netherlands)

    Lorteije, J.A.M.; Wezel, R.J.A. van; Lankheet, M.J.M.

    2002-01-01

    In a two-alternative forced-choice psychophysical test human subjects were tested for their ability to perceive their own viewing direction. A small red flash was presented at different horizontal positions left or right from the subjects' eye position on the screen. Eye positions were recorded with

  17. Irreversible electroporation of human primary uveal melanoma in enucleated eyes.

    Directory of Open Access Journals (Sweden)

    Yossi Mandel

    Full Text Available Uveal melanoma (UM is the most common primary intraocular tumor in adults and is characterized by high rates of metastatic disease. Although brachytherapy is the most common globe-sparing treatment option for small- and medium-sized tumors, the treatment is associated with severe adverse reactions and does not lead to increased survival rates as compared to enucleation. The use of irreversible electroporation (IRE for tumor ablation has potential advantages in the treatment of tumors in complex organs such as the eye. Following previous theoretical work, herein we evaluate the use of IRE for uveal tumor ablation in human ex vivo eye model. Enucleated eyes of patients with uveal melanoma were treated with short electric pulses (50-100 µs, 1000-2000 V/cm using a customized electrode design. Tumor bioimpedance was measured before and after treatment and was followed by histopathological evaluation. We found that IRE caused tumor ablation characterized by cell membrane disruption while sparing the non-cellular sclera. Membrane disruption and loss of cellular capacitance were also associated with significant reduction in total tumor impedance and loss of impedance frequency dependence. The effect was more pronounced near the pulsing electrodes and was dependent on time from treatment to fixation. Future studies should further evaluate the potential of IRE as an alternative method of uveal melanoma treatment.

  18. Eye Contricks

    Directory of Open Access Journals (Sweden)

    N Wade

    2011-04-01

    Full Text Available Icons are eye-cons: they provide a distillation of a complex object or idea into a simple pictorial shape. They create the impression of representing that which cannot be presented. Even at the level of the photograph, the links between icon and object are tenuous. The dimension of distance or depth is missing from the icon, and this alone introduces all manner of potential ambiguities. The history of art can be considered as an exploration of the missing link between icon and object. Eye-cons are more honest—they are tricks of vision so that what is seen does not necessarily correspond to what is presented. They are visual allusions rather than visual illusions, although they can display illusory effects. At its broadest, icon can be equated with image. The concept of image has thrived on its vagueness, and so attempts have been made to refine it. An icon corresponds to an optical image: it shares some of the projective characteristics of the object represented. Written words are also icons but they do not resemble the objects they represent—they are stylised or conventional rather than spatialised and projective. Words and images were set in delightful opposition by René Magritte (1898-1967 in a series of pipe paintings, and he also played on the theme of the arbitrariness of the verbal labels assigned to objects. What is surprising is that Magritte did not apply his painterly skills to transforming the word shapes he used. A similar reluctance to transform the typefaces pervades visual poetry. My interests are in the visual rather than the poetic dimension, and I will present a range of my own eye contricks which play with letter and word shapes in a variety of ways.

  19. Eye movements reveal epistemic curiosity in human observers.

    Science.gov (United States)

    Baranes, Adrien; Oudeyer, Pierre-Yves; Gottlieb, Jacqueline

    2015-12-01

    Saccadic (rapid) eye movements are primary means by which humans and non-human primates sample visual information. However, while saccadic decisions are intensively investigated in instrumental contexts where saccades guide subsequent actions, it is largely unknown how they may be influenced by curiosity - the intrinsic desire to learn. While saccades are sensitive to visual novelty and visual surprise, no study has examined their relation to epistemic curiosity - interest in symbolic, semantic information. To investigate this question, we tracked the eye movements of human observers while they read trivia questions and, after a brief delay, were visually given the answer. We show that higher curiosity was associated with earlier anticipatory orienting of gaze toward the answer location without changes in other metrics of saccades or fixations, and that these influences were distinct from those produced by variations in confidence and surprise. Across subjects, the enhancement of anticipatory gaze was correlated with measures of trait curiosity from personality questionnaires. Finally, a machine learning algorithm could predict curiosity in a cross-subject manner, relying primarily on statistical features of the gaze position before the answer onset and independently of covariations in confidence or surprise, suggesting potential practical applications for educational technologies, recommender systems and research in cognitive sciences. With this article, we provide full access to the annotated database allowing readers to reproduce the results. Epistemic curiosity produces specific effects on oculomotor anticipation that can be used to read out curiosity states.

  20. Personal identification by eyes.

    Science.gov (United States)

    Marinović, Dunja; Njirić, Sanja; Coklo, Miran; Muzić, Vedrana

    2011-09-01

    Identification of persons through the eyes is in the field of biometrical science. Many security systems are based on biometric methods of personal identification, to determine whether a person is presenting itself truly. The human eye contains an extremely large number of individual characteristics that make it particularly suitable for the process of identifying a person. Today, the eye is considered to be one of the most reliable body parts for human identification. Systems using iris recognition are among the most secure biometric systems.

  1. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips ... addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | ...

  2. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips ... addressed to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | ...

  3. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... Eye Treatment What Is Dry Eye? Leer en Español: ¿Qué Es el Ojo Seco? Written By: Kierstan ...

  4. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  5. About the Eye

    Medline Plus

    Full Text Available ... Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision Tips Protective Eyewear Sports and Your Eyes Fun Stuff Cool Eye Tricks Links to More Information Optical Illusions Printables About the Eye Your eyes ...

  6. Comparison of in vitro eye irritation potential by bovine corneal opacity and permeability (BCOP) assay to erythema scores in human eye sting test of surfactant-based formulations.

    Science.gov (United States)

    Cater, Kathleen C; Harbell, John W

    2008-01-01

    The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.

  7. Blue eyes in lemurs and humans: same phenotype, different genetic mechanism

    DEFF Research Database (Denmark)

    Bradley, Brenda J; Pedersen, Anja; Mundy, Nicholas I

    2009-01-01

    Almost all mammals have brown or darkly-pigmented eyes (irises), but among primates, there are some prominent blue-eyed exceptions. The blue eyes of some humans and lemurs are a striking example of convergent evolution of a rare phenotype on distant branches of the primate tree. Recent work...... on humans indicates that blue eye color is associated with, and likely caused by, a single nucleotide polymorphism (rs12913832) in an intron of the gene HERC2, which likely regulates expression of the neighboring pigmentation gene OCA2. This raises the immediate question of whether blue eyes in lemurs might...... have a similar genetic basis. We addressed this by sequencing the homologous genetic region in the blue-eyed black lemur (Eulemur macaco flavifrons; N = 4) and the closely-related black lemur (Eulemur macaco macaco; N = 4), which has brown eyes. We then compared a 166-bp segment corresponding...

  8. Temperature distribution simulation of the human eye exposed to laser radiation.

    Science.gov (United States)

    Mirnezami, Seyyed Abbas; Rajaei Jafarabadi, Mahdi; Abrishami, Maryam

    2013-01-01

    Human eye is a sensitive part of human body with no direct protection and due to its lack of protection against the external heat waves, studying the temperature distribution of heat waves on the human eye is of utmost importance. Various lasers are widely used in medical applications such as eye surgeries. The most significant issue in the eye surgeries with laser is estimation of temperature distribution and its increase in eye tissues due to the laser radiation intensity. Experimental and invasive methods to measure the eye temperature usually have high risks. In this paper, human eye has been modeled through studying the temperature distribution of three different laser radiations, using the finite element method. We simulated human eye under 1064 nm Neodymium-Doped Yttrium Aluminium Garnet (Nd: YAG) laser, 193 nm argon fluoride (ArF) excimer laser, and 1340 nm Neodymium doped Yttrium Aluminum Perovskite (Nd: YAP) laser radiation. The results show that these radiations cause temperature rise in retina, lens and cornea region, which will in turn causes serious damages to the eye tissues. This simulation can be a useful tool to study and predict the temperature distribution in laser radiation on the human eye and evaluate the risk involved in using laser to perform surgery.

  9. Efficient Avoidance of the Penalty Zone in Human Eye Movements

    Science.gov (United States)

    Theeuwes, Jan

    2016-01-01

    People use eye movements extremely effectively to find objects of interest in a cluttered visual scene. Distracting, task-irrelevant attention capturing regions in the visual field should be avoided as they jeopardize the efficiency of search. In the current study, we used eye tracking to determine whether people are able to avoid making saccades to a predetermined visual area associated with a financial penalty, while making fast and accurate saccades towards stimuli placed near the penalty area. We found that in comparison to the same task without a penalty area, the introduction of a penalty area immediately affected eye movement behaviour: the proportion of saccades to the penalty area was immediately reduced. Also, saccadic latencies increased, but quite modestly, and mainly for saccades towards stimuli near the penalty area. We conclude that eye movement behaviour is under efficient cognitive control and thus quite flexible: it can immediately be adapted to changing environmental conditions to improve reward outcome. PMID:27930724

  10. Eye Injuries in Sports

    Science.gov (United States)

    ... in Sports Which sports cause the most eye injuries?Sports cause more than 40,000 eye injuries each ... and racquet sports.When it comes to eye injuries, sports can be classified as low risk, high risk ...

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Member Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member ... Center Redmond Ethics Center Global Ophthalmology Guide Eye Health Find an Ophthalmologist Academy Store Eye Health A- ...

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Member Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member ... Center Redmond Ethics Center Global Ophthalmology Guide Eye Health Find an Ophthalmologist Academy Store Eye Health A- ...

  13. Eye muscle repair - slideshow

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/presentations/100062.htm Eye muscle repair - series—Normal anatomy To use the sharing ... the eyeball to the eye socket. The external muscles of the eye are found behind the conjunctiva. ...

  14. Pink Eye (Conjunctivitis)

    Science.gov (United States)

    ... you have allergic conjunctivitis. Preventing the spread of pink eye Practice good hygiene to control the spread ... can return to school or child care. Preventing pink eye in newborns Newborns' eyes are susceptible to ...

  15. About the Eye

    Medline Plus

    Full Text Available ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  16. About the Eye

    Science.gov (United States)

    ... Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid Tips Healthy Vision ... to More Information Optical Illusions Printables About the Eye Your eyes are made up of many different ...

  17. Eye Injuries (For Parents)

    Science.gov (United States)

    ... Habits for TV, Video Games, and the Internet Eye Injuries KidsHealth > For Parents > Eye Injuries Print A ... sand, dirt, and other foreign bodies on the eye surface) Wash your hands thoroughly before touching the ...

  18. Laser photocoagulation - eye

    Science.gov (United States)

    Laser coagulation; Laser eye surgery; Photocoagulation; Laser photocoagulation - diabetic eye disease; Laser photocoagulation - diabetic retinopathy; Focal photocoagulation; Scatter (or pan retinal) photocoagulation; Proliferative ...

  19. Gazing-detection of human eyes based on SVM

    Institute of Scientific and Technical Information of China (English)

    LI Su-mei; ZHANG Yan-xin; CHANG Sheng-jiang; SHEN Jin-yuan

    2005-01-01

    A method for gazing-detection of human eyes using Support Vector Machine (SVM) based on statistic learning theory (SLT) is proposed.According to the criteria of structural risk minimization of SVM,the errors between sample-data and model-data are minimized and the upper bound of predicting error of the model is also reduced.As a result,the generalization ability of the model is much improved.The simulation results show that,when limited training samples are used,the correct recognition rate of the tested samples can be as high as 100%,which is much better than some previous results obtained by other methods.The higher processing speed enables the system to distinguish gazing or not-gazing in real-time.

  20. EyeFrame: Real-time memory aid improves human multitasking via domain-general eye tracking procedures

    Directory of Open Access Journals (Sweden)

    P. eTaylor

    2015-09-01

    Full Text Available OBJECTIVE: We developed an extensively general closed-loop system to improve human interaction in various multitasking scenarios, with semi-autonomous agents, processes, and robots. BACKGROUND: Much technology is converging toward semi-independent processes with intermittent human supervision distributed over multiple computerized agents. Human operators multitask notoriously poorly, in part due to cognitive load and limited working memory. To multitask optimally, users must remember task order, e.g., the most neglected task, since longer times not monitoring an element indicates greater probability of need for user input. The secondary task of monitoring attention history over multiple spatial tasks requires similar cognitive resources as primary tasks themselves. Humans can not reliably make more than ~2 decisions/s. METHODS: Participants managed a range of 4-10 semi-autonomous agents performing rescue tasks. To optimize monitoring and controlling multiple agents, we created an automated short term memory aid, providing visual cues from users' gaze history. Cues indicated when and where to look next, and were derived from an inverse of eye fixation recency. RESULTS: Contingent eye tracking algorithms drastically improved operator performance, increasing multitasking capacity. The gaze aid reduced biases, and reduced cognitive load, measured by smaller pupil dilation. CONCLUSIONS: Our eye aid likely helped by delegating short-term memory to the computer, and by reducing decision making load. Past studies used eye position for gaze-aware control and interactive updating of displays in application-specific scenarios, but ours is the first to successfully implement domain-general algorithms. Procedures should generalize well to: process control, factory operations, robot control, surveillance, aviation, air traffic control, driving, military, mobile search and rescue, and many tasks where probability of utility is predicted by duration since last

  1. To Estimate the Axial Elastic Modulus of Eye and Posterior Wall Thickness in Healthy Human Eye by Ultrasound Images and their Relation with Age and Gender

    Directory of Open Access Journals (Sweden)

    S. Shahbazi

    2007-06-01

    Full Text Available Introduction: Based on the invasive studies it has been shown that factors such as age, the progress of eye disorders, lens fibers compression and the biochemical changes of ocular matrix alter the physical characteristics and elastic properties of eye. In this study, a noninvasive method of estimating human eye elasticityis proposed and its relation with age and gender is evaluated using ultrasound images. Materials and Methods: To estimate eye elasticity, an especial loading system was designed and an external stress of 2614 ± 146 Pa which is less than the intraocular pressure of eye was applied to 20 eyes in an in vivo study. The pressure was measured using digital force gauge. The ultrasound images of B-mode were acquired prior to and post applying the stress. For the offline study throughout the loading process, the ultrasound images were saved as multi-frames into the computer by video grabber board. Monitoring, saving and further study of images were provided for the extraction of eye axial length and posterior wall thickness (PWT. The elasticity was estimated by measuring the relative changes of the axial length of eye, the posterior wall thickness and the applied stress. The statistical correlation of elastic modulus was analyzed based on age and gender. Results: The elastic modulus of the eye and the posterior wall thickness was estimated to be 51,777 ± 27304 and 14603 ± 4636 Pa, respectively. The obtained results indicated that there was no significant difference between the elastic parameters of the eye and the posterior wall thickness based on gender in both male and female group. The correlation analysis of the elastic parameter showed that there was significant difference between the eye and the posterior wall thickness based on age with a 95% confidence interval. Discussion and Conclusion: Based on the results obtained in this study the ultrasonic instruments might be used to estimate the hardness of eye lesions as well as eye

  2. Eating for Your Eyes

    Science.gov (United States)

    Stastny, Sherri Nordstrom; Garden-Robinson, Julie

    2011-01-01

    An educational program targeting older adults was developed to increase knowledge regarding nutrition and eye health. With age, the chance for eye disease increases, so prevention is critical. The Eating for Your Eyes program has promoted behavior changes regarding eye health among the participants. This program is easily replicated and use is…

  3. Eye Injuries (For Parents)

    Science.gov (United States)

    ... the eye nausea or vomiting after an eye injury Think Prevention! Kids who play sports should wear protective goggles or unbreakable glasses as needed. Keep chemicals and other potentially dangerous objects out of the reach of children. Reviewed by: Steven Dowshen, ... (Conjunctivitis) Eyes Corneal Abrasions Styes Activity: Eyes ...

  4. Implicit prosody mining based on the human eye image capture technology

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of

  5. Repeatability and reliability of human eye in visual shade selection.

    Science.gov (United States)

    Özat, P B; Tuncel, İ; Eroğlu, E

    2013-12-01

    Deficiencies in the human visual percep-tion system have challenged the efficiency of the visual shade-matching protocol. The aim of this study was to evaluate the repeatability and reliability of human eye in visual shade selection. Fifty-four volunteering dentists were asked to match the shade of an upper right central incisor tooth of a single subject. The Vita 3D-Master shade guide was used for the protocol. Before each shade-matching procedure, the definitive codes of the shade tabs were hidden by an opaque strip and the shade tabs were placed into the guide randomly. The procedure was repeated 1 month later to ensure that visual memory did not affect the results. The L*, a* and b* values of the shade tabs were measured with a dental spectrophotometer (Vita Easyshade) to produce quantitative values to evaluate the protocol. The paired samples t-test and Pearson correlation test were used to compare the 1st and 2nd selections. The Yates-corrected chi-square test was use to compare qualitative values. Statistical significance was accepted at P shade matching, but they are able to select clinically acceptable shades.

  6. Intraoperative length and tension curves of human eye muscles. Including stiffness in passive horizontal eye movement in awake volunteers

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); G.H. Kolling (Gerold); H. Kaufmann (Herbert); B. van Dijk (Bob)

    1986-01-01

    textabstractIntraoperative continuous-registration length and tension curves of attached and detached eye muscles were made in 18 strabismic patients under general anesthesia. For relaxed eye muscles, we found an exponential relation between length and tension. An increased stiffness was quantified

  7. Digital quantification of human eye color highlights genetic association of three new loci.

    NARCIS (Netherlands)

    F. Liu (Fan); A. Wollstein (Andreas); P.G. Hysi (Pirro); G.A. Ankra-Badu (Georgina); T.D. Spector (Timothy); D.J. Park (Daniel); G. Zhu; M. Larsson (Mats); D.L. Duffy (David); G.W. Montgomery (Grant); D.A. Mackey (David); S. Walsh (Susan); O. Lao Grueso (Oscar); A. Hofman (Albert); F. Rivadeneira Ramirez (Fernando); J.R. Vingerling (Hans); A.G. Uitterlinden (André); N.G. Martin (Nicholas); C.J. Hammond (Christopher); M.H. Kayser (Manfred)

    2010-01-01

    textabstractPrevious studies have successfully identified genetic variants in several genes associated with human iris (eye) color; however, they all used simplified categorical trait information. Here, we quantified continuous eye color variation into hue and saturation values using high-resolution

  8. Measurement of the mechanical stiffness in cyclotorsion of the human eye

    NARCIS (Netherlands)

    H.J. Simonsz (Huib)

    1984-01-01

    textabstractWe have measured the stiffness in cyclotorsion of the human eye using a scleral suction contact ring mounted on a shaft fitted with an eddy current motor to provide the torque to turn the eye and a shaft-position-encoder to register the torsion. The relation proved to be almost linear wi

  9. NMR Spectroscopy of Human Eye Tissues: A New Insight into Ocular Biochemistry

    Directory of Open Access Journals (Sweden)

    Tomasz Kryczka

    2014-01-01

    Full Text Available Background. The human eye is a complex organ whose anatomy and functions has been described very well to date. Unfortunately, the knowledge of the biochemistry and metabolic properties of eye tissues varies. Our objective was to reveal the biochemical differences between main tissue components of human eyes. Methods. Corneas, irises, ciliary bodies, lenses, and retinas were obtained from cadaver globes 0-1/2 hours postmortem of 6 male donors (age: 44–61 years. The metabolic profile of tissues was investigated with HR MAS 1H NMR spectroscopy. Results. A total of 29 metabolites were assigned in the NMR spectra of the eye tissues. Significant differences between tissues were revealed in contents of the most distant eye-tissues, while irises and ciliary bodies showed minimal biochemical differences. ATP, acetate, choline, glutamate, lactate, myoinositol, and taurine were identified as the primary biochemical compounds responsible for differentiation of the eye tissues. Conclusions. In this study we showed for the first time the results of the analysis of the main human eye tissues with NMR spectroscopy. The biochemical contents of the selected tissues seemed to correspond to their primary anatomical and functional attributes, the way of the delivery of the nutrients, and the location of the tissues in the eye.

  10. High-speed adaptive optics line scan confocal retinal imaging for human eye.

    Science.gov (United States)

    Lu, Jing; Gu, Boyu; Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye's optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss.

  11. The Human Eye Position Control System in a Rehabilitation Setting

    Directory of Open Access Journals (Sweden)

    Yvonne Nolan

    2005-01-01

    Full Text Available Our work at Ireland’s National Rehabilitation Hospital involves designing communication systems for people suffering from profound physical disabilities. One such system uses the electro-oculogram, which is an (x,y system of voltages picked up by pairs of electrodes placed, respectively, above and below and on either side of the eyes. The eyeball has a dc polarisation between cornea and back, arising from the photoreceptor rods and cones in the retina. As the eye rotates, the varying voltages projected onto the electrodes drive a cursor over a mimic keyboard on a computer screen. Symbols are selected with a switching action derived, for example, from a blink. Experience in using this mode of communication has given us limited facilities to study the eye position control system. We present here a resulting new feedback model for rotation in either the vertical or the horizontal plane, which involves the eyeball controlled by an agonist-antagonist muscle pair, modelled by a single equivalent bidirectional muscle with torque falling off linearly with angular velocity. We have incorporated muscle spindles and have tuned them by pole assignment associated with an optimum stability criterion.

  12. Imaging shear stress distribution and evaluating the stress concentration factor of the human eye

    Science.gov (United States)

    Joseph Antony, S.

    2015-03-01

    Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.

  13. Eye Drop Tips

    Science.gov (United States)

    ... Involved News About Us Donate In This Section Eye Drop Tips en Español email Send this article ... the reach of children. Steps For Putting In Eye Drops: Start by tilting your head backward while ...

  14. What Is Dry Eye?

    Medline Plus

    Full Text Available ... information about eye health and preserving your vision. Privacy Policy Related New Dry Eye Treatment is a ... the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media ...

  15. What Is Dry Eye?

    Medline Plus

    Full Text Available ... is also when your eyes do not make the right type of tears. How do tears work? ... you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... tissue covering the white of your eye and inside your eyelids. Normally, our eyes constantly make tears ... Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical ...

  17. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Pediatric Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Eye ... What Is Dry Eye? Leer en Español: ¿Qué ...

  18. TUBERCULOSIS AND THE EYE

    African Journals Online (AJOL)

    Key words: Mycobacteria; Tuberculosis; Eye ... of tuberculous eye disease or ocular tuberculosis has also been raised. Ocular ... patients with ocular complaints, compiled in an area ..... tuberculomas are usually solitary and may measure up.

  19. About the Eye

    Medline Plus

    Full Text Available ... you see. Check out the diagrams below to learn about each part of your eye and what ... the optic nerve to the brain. Watch now! Learn how the different parts of your eye work ...

  20. About the Eye

    Medline Plus

    Full Text Available ... The Visual System Your Eyes’ Natural Defenses Eye Health and Safety First Aid ... Your eyes are made up of many different parts that work together to help you see. Check out the ...

  1. What Is Dry Eye?

    Medline Plus

    Full Text Available ... about eye health and preserving your vision. Privacy Policy Related New Dry Eye Treatment is a Tear- ... Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology ...

  2. Preventing eye injuries

    Directory of Open Access Journals (Sweden)

    Daksha Patel

    2016-01-01

    Full Text Available The main challenge in developing a strategy to prevent eye injuries is that there are so many different causes and situations that can lead to eye injuries, each requiring a different approach.

  3. Common Eye Disorders

    Science.gov (United States)

    ... www.cdc.gov/emailupdates/">What's this? Submit Button Common Eye Disorders Recommend on Facebook Tweet Share Compartir ... macular degeneration, cataract, diabetic retinopathy, and glaucoma. Other common eye disorders include amblyopia and strabismus. For a ...

  4. Can human eyes prevent perceptual narrowing for monkey faces in human infants?

    Science.gov (United States)

    Damon, Fabrice; Bayet, Laurie; Quinn, Paul C; Hillairet de Boisferon, Anne; Méary, David; Dupierrix, Eve; Lee, Kang; Pascalis, Olivier

    2015-07-01

    Perceptual narrowing has been observed in human infants for monkey faces: 6-month-olds can discriminate between them, whereas older infants from 9 months of age display difficulty discriminating between them. The difficulty infants from 9 months have processing monkey faces has not been clearly identified. It could be due to the structural characteristics of monkey faces, particularly the key facial features that differ from human faces. The current study aimed to investigate whether the information conveyed by the eyes is of importance. We examined whether the presence of Caucasian human eyes in monkey faces allows recognition to be maintained in 6-month-olds and facilitates recognition in 9- and 12-month-olds. Our results revealed that the presence of human eyes in monkey faces maintains recognition for those faces at 6 months of age and partially facilitates recognition of those faces at 9 months of age, but not at 12 months of age. The findings are interpreted in the context of perceptual narrowing and suggest that the attenuation of processing of other-species faces is not reversed by the presence of human eyes.

  5. Research of the Exploitation of Human Resources in Blind Prevention and Primary Eye Care

    Institute of Scientific and Technical Information of China (English)

    JingxianWei; YonglongZhao

    1995-01-01

    Purpose:This research studied how to establish a relatively advanced blindness prevention and eye care cause in economically underdeveloped countryside.Methods:Ophthalmic vocational schools and professional lectures were held to train“practical type”primary eye care workers for the coumtryside.Further study in high-level(above provincial)hospitals was taken to train blindness preention &eye care backbones and leaders.Results:In 1986,the ratio of the number of the eye care workers of all levels to the number of the whole population in the prefecture was1:26000.In1992,it roseto1:17000.Aneye care network of 222stations had been established in tb countryside.Ten in the 13county hospitals had a seperated ophthalmology ed- partment,in which 3were awarded“National advanced blindness prevention County”.Twenty one hospitals were appointed as the Unit of Surgical Vision-Rehabilitation of Cataract.Blindness prevention and eye care convered1000000population(eye care avaliable within 5kilometers),23.5%of the whol popula-tion.Conclusions:In a demographically large but economically underdexeloped country-side area,the key to wide-range blindness prevention and eye oare is to exploti human resources effectively.We should train“Practical type”primary eye care workers,and have a number of edpartment leaders who are authoritive,influential in this field and ready to sacrifice to this cause.

  6. Effect of tissue and atmosphere's parameters on human eye temperature distribution.

    Science.gov (United States)

    Firoozan, Mohammad Sadegh; Porkhial, Soheil; Nejad, Ali Salmani

    2015-01-01

    A three dimensional finite element method analysis was employed to investigate the effect of tissue and atmosphere parameters namely, ambient temperature, ambient convection coefficient, local blood temperature, and blood convection coefficient upon temperature distribution of human eyes. As a matter of simplification, only eye ball and skull bone are considered as the system of eye modeling. Decreasing the local blood temperature and keeping it cool is one of the most important ways to control bleeding during surgeries. By lower temperature of body organs such as the eye, the need for oxygenated blood is reduced, allowing for an extension in time for surgery. With this in mind, this study is done to see which one of parameters, such as ambient temperature, ambient convection coefficient, local blood temperature, and blood convection coefficient, has an effective role in decreasing the temperature of the eye. To this end, 3 different paths were employed to find out about the temperature distribution through the eye. The analysis of the three paths demonstrates the interaction of ambient and blood temperature in modeling temperature changes in specific locations of the eye. These data will be important in applications such as eye surgery, relaxation, and sleep therapy.

  7. Dating the time of birth: a radiocarbon calibration curve for human eye lens crystallines

    DEFF Research Database (Denmark)

    Kjeldsen, Henrik; Heinemeier, Jan; Heegaard, Steffen

    2010-01-01

    Radiocarbon bomb-pulse dating has been used to measure the formation age of human eye-lens crystallines. Lens crystallines are special proteins in the eye-lens that consist of virtually inert tissue. The experimental data show that the radiocarbon ages to a large extent reflect the time of birth......, in accordance with expectations. Moreover, it has been possible to develop an age model for the formation of the eye-lens crystallines. From this model a radiocarbon calibration curve for lens crystallines has been calculated. As a consequence, the time of birth of humans can be determined with an accuracy...

  8. Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, Casey Robert [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bower, Gordon Ross [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spielman, Zachary Alexander [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hill, Rachael Ann [Idaho National Lab. (INL), Idaho Falls, ID (United States); LeBlanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-11-01

    Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

  9. The all seeing eye?

    NARCIS (Netherlands)

    Koenderink, Jan J.

    2014-01-01

    The All Seeing Eye? Did you know that you are probably a believer in the All Seeing Eye? The odds are that I’m right—why? Well, the bulk of mainstream vision literature blindly relies on the All Seeing Eye. It is written all over papers, albeit between the lines. Understandably so, for scientists re

  10. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Tips & Prevention News Ask an Ophthalmologist Patient Stories Español Eye Health / Eye Health A-Z Dry Eye ... when I sleep? Feb 10, 2016 Leer en Español: ¿Qué Es el Ojo Seco? Find an Ophthalmologist ...

  12. About the Eye

    Medline Plus

    Full Text Available ... other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health ... Eye Ask a Scientist Video Series Glossary The Visual System Your Eyes’ Natural Defenses Eye Health and ...

  13. The all seeing eye?

    NARCIS (Netherlands)

    Koenderink, Jan J.|info:eu-repo/dai/nl/070864543

    2014-01-01

    The All Seeing Eye? Did you know that you are probably a believer in the All Seeing Eye? The odds are that I’m right—why? Well, the bulk of mainstream vision literature blindly relies on the All Seeing Eye. It is written all over papers, albeit between the lines. Understandably so, for scientists

  14. Simple, inexpensive technique for high-quality smartphone fundus photography in human and animal eyes

    National Research Council Canada - National Science Library

    Haddock, Luis J; Kim, David Y; Mukai, Shizuo

    2013-01-01

    Purpose. We describe in detail a relatively simple technique of fundus photography in human and rabbit eyes using a smartphone, an inexpensive app for the smartphone, and instruments that are readily...

  15. Simple, Inexpensive Technique for High-Quality Smartphone Fundus Photography in Human and Animal Eyes

    National Research Council Canada - National Science Library

    Haddock, Luis J; Kim, David Y; Mukai, Shizuo

    2013-01-01

    Purpose. We describe in detail a relatively simple technique of fundus photography in human and rabbit eyes using a smartphone, an inexpensive app for the smartphone, and instruments that are readily...

  16. Pharmacokinetics of bevacizumab after topical and intravitreal administration in human eyes

    OpenAIRE

    Moisseiev, Elad; Waisbourd, Michael; Ben-Artsi, Elad; Levinger, Eliya; Barak, Adiel; Daniels, Tad; Csaky, Karl; Loewenstein, Anat; Barequet, Irina S.

    2013-01-01

    Background Topical bevacizumab is a potential treatment modality for corneal neovascularization, and several recent studies have demonstrated its efficacy. No previous study of the pharmacokinetics of topical bevacizumab has been performed in human eyes. The purpose of this study is to investigate the pharmacokinetics of topical administration of bevacizumab in human eyes, and also to compare the pharmacokinetics of intravitreal bevacizumab injections with previously reported data. Methods Tw...

  17. Medicare Benefits and Your Eyes

    Science.gov (United States)

    ... Subscribe to eNews Close Donate Medicare Benefits & Your Eyes Eye Health is Important! As you age, your risk ... that you need. Ask about eye exams! Routine Eye Exams Medicare does not generally cover the costs ...

  18. Prevent Eye Injuries from Fireworks

    Science.gov (United States)

    ... Financial Assistance Information Vision Screening and Eye Exams Zika Virus and Vision Eye Problems Eye Problems Amblyopia ( ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision ...

  19. High-speed adaptive optics line scan confocal retinal imaging for human eye

    Science.gov (United States)

    Wang, Xiaolin; Zhang, Yuhua

    2017-01-01

    Purpose Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. Methods A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye’s optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. Results The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. Conclusions We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss. PMID:28257458

  20. Early visual evoked potentials are modulated by eye position in humans induced by whole body rotations

    Directory of Open Access Journals (Sweden)

    Petit Laurent

    2004-09-01

    Full Text Available Abstract Background To reach and grasp an object in space on the basis of its image cast on the retina requires different coordinate transformations that take into account gaze and limb positioning. Eye position in the orbit influences the image's conversion from retinotopic (eye-centered coordinates to an egocentric frame necessary for guiding action. Neuroimaging studies have revealed eye position-dependent activity in extrastriate visual, parietal and frontal areas that is along the visuo-motor pathway. At the earliest vision stage, the role of the primary visual area (V1 in this process remains unclear. We used an experimental design based on pattern-onset visual evoked potentials (VEP recordings to study the effect of eye position on V1 activity in humans. Results We showed that the amplitude of the initial C1 component of VEP, acknowledged to originate in V1, was modulated by the eye position. We also established that putative spontaneous small saccades related to eccentric fixation, as well as retinal disparity cannot explain the effects of changing C1 amplitude of VEP in the present study. Conclusions The present modulation of the early component of VEP suggests an eye position-dependent activity of the human primary visual area. Our findings also evidence that cortical processes combine information about the position of the stimulus on the retinae with information about the location of the eyes in their orbit as early as the stage of primary visual area.

  1. Nonlinear solution for radiation boundary condition of heat transfer process in human eye.

    Science.gov (United States)

    Dehghani, A; Moradi, A; Dehghani, M; Ahani, A

    2011-01-01

    In this paper we propose a new method based on finite element method for solving radiation boundary condition of heat equation inside the human eye and other applications. Using this method, we can solve heat equation inside human eye without need to model radiation boundary condition to a robin boundary condition. Using finite element method we can obtain a nonlinear equation, and finally we use nonlinear algorithm to solve it. The human eye is modeled as a composition of several homogeneous regions. The Ritz method in the finite element method is used for solving heat differential equation. Applying the boundary conditions, the heat radiation condition and the robin condition on the cornea surface of the eye and on the outer part of sclera are used, respectively. Simulation results of solving nonlinear boundary condition show the accuracy of the proposed method.

  2. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  3. Concept of a human eye camera to assess laser dazzling interaction

    Science.gov (United States)

    Koerber, Michael; Eberle, Bernd

    2016-10-01

    The increase in availability and application of various laser sources poses an increasing threat to the human eye. Not only the actual damage dealt to the retina or other parts of the eye, but also dazzling during critical tasks has to be faced. However, experiments to verify the actual threat due to dazzling are quite critical, as it is almost never possible or even reasonable, to dazzle human observers. Based on this dilemma, we propose to construct a camera that mimics the perception of laser dazzle by the human eye as close as possible. The human eye camera consists of hardware and a software component, which perform the several tasks of the eye. The hardware controls the eye-movement (saccadic viewing), the adaption of the iris (irradiance control) and the projection of the image onto a sensor. The software receives the image taken by the sensor and includes the density of receptors, the retinal neural operations and a feedback to the hardware. The processed images by the virtual retina are meant to be used to evaluate the degree of dazzling, as it would occur to a human observer.

  4. Curvature sensor for the measurement of the static corneal topography and the dynamic tear film topography in the human eye

    Science.gov (United States)

    Gruppetta, Steve; Koechlin, Laurent; Lacombe, François; Puget, Pascal

    2005-10-01

    A system to measure the topography of the first optical surface of the human eye noninvasively by using a curvature sensor is described. The static corneal topography and the dynamic topography of the tear film can both be measured, and the topographies obtained are presented. The system makes possible the study of the dynamic aberrations introduced by the tear film to determine their contribution to the overall ocular aberrations in healthy eyes, eyes with corneal pathologies, and eyes wearing contact lenses.

  5. Activation of neural progenitor cells in human eyes with proliferative vitreoretinopathy.

    Science.gov (United States)

    Johnsen, Erik O; Frøen, Rebecca C; Albert, Réka; Omdal, Bente K; Sarang, Zsolt; Berta, András; Nicolaissen, Bjørn; Petrovski, Goran; Moe, Morten C

    2012-05-01

    In addition to the ability for self-renewal and functional differentiation, neural stem/progenitor cells (NSCs) can respond to CNS injuries by targeted migration. In lower vertebrates, retinal injury is known to activate NSCs in the ciliary marginal zone (CMZ). Cells expressing markers of NSCs are also present in the ciliary body epithelium (CE) and in Müller glia in the peripheral retina (PR) of the adult human eye. However, these cells seem to be quiescent in the adult human eye and recent reports have shown that CE cells have limited properties of NSCs. In order to further clarify whether NSCs exist in the adult human eye, we tested whether NSC-like cells could be activated in eyes with proliferative vitreoretinopathy (PVR). The PR and CE were studied for NSC-associated markers in human enucleated control eyes and eyes with confirmed PVR, as well as in a mouse model of PVR. Furthermore, cells isolated from vitreous samples obtained during vitrectomies for retinal detachment were directly fixed or cultured in a stem cell-promoting medium and compared to cells cultured from the post-mortem retina and CE. In situ characterization of the normal eyes revealed robust expression of markers present in NSCs (Nestin, Sox2, Pax6) only around peripheral cysts of the proximal pars plana region and the PR, the latter population also staining for the glial marker GFAP. Although there were higher numbers of dividing cells in the CE of PVR eyes than in controls, we did not detect NSC-associated markers in the CE except around the proximal pars plana cysts. In the mice PVR eyes, Nestin activation was also found in the CE. In human PVR eyes, proliferation of both non-glial and glial cells co-staining NSC-associated markers was evident around the ora serrata region. Spheres formed in 7/10 vitreous samples from patients with PVR compared to 2/15 samples from patients with no known PVR, and expressed glial - and NSC-associated markers both after direct fixation and repetitive

  6. Human eye analytical and mesh-geometry models for ophthalmic dosimetry using MCNP6

    Energy Technology Data Exchange (ETDEWEB)

    Angelocci, Lucas V.; Fonseca, Gabriel P.; Yoriyaz, Helio, E-mail: hyoriyaz@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Eye tumors can be treated with brachytherapy using Co-60 plaques, I-125 seeds, among others materials. The human eye has regions particularly vulnerable to ionizing radiation (e.g. crystalline) and dosimetry for this region must be taken carefully. A mathematical model was proposed in the past [1] for the eye anatomy to be used in Monte Carlo simulations to account for dose distribution in ophthalmic brachytherapy. The model includes the description for internal structures of the eye that were not treated in previous works. The aim of this present work was to develop a new eye model based on the Mesh geometries of the MCNP6 code. The methodology utilized the ABAQUS/CAE (Simulia 3DS) software to build the Mesh geometry. For this work, an ophthalmic applicator containing up to 24 model Amersham 6711 I-125 seeds (Oncoseed) was used, positioned in contact with a generic tumor defined analytically inside the eye. The absorbed dose in eye structures like cornea, sclera, choroid, retina, vitreous body, lens, optical nerve and optical nerve wall were calculated using both models: analytical and MESH. (author)

  7. The expression of Mas-receptor of the renin-angiotensin system in the human eye.

    Science.gov (United States)

    Vaajanen, A; Kalesnykas, G; Vapaatalo, H; Uusitalo, H

    2015-07-01

    The local renin-angiotensin system has been held to be expressed in many organs, including the eye. It has an important role in the regulation of local fluid homeostasis, cell proliferation, fibrosis, and vascular tone. Mas-receptor (Mas-R) is a potential receptor acting mainly opposite to the well-known angiotensin II receptor type 1. The aim of this study was to determine if Mas-R is expressed in the human eye. Seven enucleated human eyes were used in immunohistochemical detection of Mas-R and its endogenous ligand angiotensin (1-7) [Ang(1-7)]. Both light microscopy and immunofluorescent detection methods were used. A human kidney preparation sample was used as control. The Mas-R was found to have nuclear localization, and localized in the retinal nuclear layers and in the structures of the anterior segment of the eye. A cytoplasmic immunostaining pattern of Ang(1-7) was found in the inner and outer nuclear and plexiform layers of the retina and in the ciliary body. To the best of our knowledge, this is the first report showing Mas-R expression in the human eye. Its localization suggests that it may have a role in physiological and pathological processes in the anterior part of the eye and in the retina.

  8. Proton Dose Assessment to the Human Eye Using Monte Carlo N-Particle Transport Code (MCNPX)

    Science.gov (United States)

    2006-08-01

    objective of this project was to develop a simple MCNPX model of the human eye to approximate dose delivered from proton therapy. The calculated dose...computer code MCNPX that approximates dose delivered during proton therapy. The calculations considered proton interactions and secondary interactions...Volume Calculation The MCNPX code has limited ability to compute the volumes of defined cells. The dosimetric volumes in the outer wall of the eye are

  9. Basement membrane abnormalities in human eyes with diabetic retinopathy

    DEFF Research Database (Denmark)

    Ljubimov, A V; Burgeson, R E; Butkowski, R J

    1996-01-01

    discontinuously for laminin-1, entactin/nidogen, and alpha3-alpha4 Type IV collagen, in contrast to non-DR corneas. Major BM alterations were found in DR retinas compared to normals and non-DR diabetics. The inner limiting membrane (retinal BM) of DR eyes had accumulations of fibronectin (including cellular......) and Types I, III, IV (alpha1-alpha2), and V collagen. The BM zone of new retinal blood vessels in neovascularized areas accumulated tenascin and Type XII collagen, whereas normal, diabetic, and adjacent DR retinas showed only weak and irregular staining. In preretinal membranes, perlecan, bamacan, and Types...... VI, VIII, XII, and XIV collagen were newly identified. Diabetic BM thickening appears to involve qualitative alterations of specific BM markers at an advanced disease stage, with the appearance of DR....

  10. Robot Arm Control and Having Meal Aid System with Eye Based Human-Computer Interaction (HCI)

    Science.gov (United States)

    Arai, Kohei; Mardiyanto, Ronny

    Robot arm control and having meal aid system with eye based HCI is proposed. The proposed system allows disabled person to select desirable food from the meal tray by their eyes only. Robot arm which is used for retrieving the desirable food is controlled by human eye. At the tip of the robot arm, tiny camera is equipped. Disabled person wear a glass of which a single Head Mount Display: HMD and tiny camera is mounted so that disabled person can take a look at the desired food and retrieve it by looking at the food displayed onto HMD. Experimental results show that disabled person can retrieve the desired food successfully. It also is confirmed that robot arm control by eye based HCI is much faster than that by hands.

  11. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Academy Publications EyeNet Ophthalmology Ophthalmology Retina Information for: International Ophthalmologists Media Medical Students Patients and Public Technicians and Nurses Senior Ophthalmologists ...

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics ... Services Advocacy Foundation About Subspecialties & More Eye ...

  13. Identification of lymphatics in the ciliary body of the human eye: a novel "uveolymphatic" outflow pathway.

    Science.gov (United States)

    Yücel, Yeni H; Johnston, Miles G; Ly, Tina; Patel, Manoj; Drake, Brian; Gümüş, Ersin; Fraenkl, Stephan A; Moore, Sara; Tobbia, Dalia; Armstrong, Dianna; Horvath, Eva; Gupta, Neeru

    2009-11-01

    Impaired aqueous humor flow from the eye may lead to elevated intraocular pressure and glaucoma. Drainage of aqueous fluid from the eye occurs through established routes that include conventional outflow via the trabecular meshwork, and an unconventional or uveoscleral outflow pathway involving the ciliary body. Based on the assumption that the eye lacks a lymphatic circulation, the possible role of lymphatics in the less well defined uveoscleral pathway has been largely ignored. Advances in lymphatic research have identified specific lymphatic markers such as podoplanin, a transmembrane mucin-type glycoprotein, and lymphatic vessel endothelial hyaluronan receptor-1 (LYVE-1). Lymphatic channels were identified in the human ciliary body using immunofluorescence with D2-40 antibody for podoplanin, and LYVE-1 antibody. In keeping with the criteria for lymphatic vessels in conjunctiva used as positive control, D2-40 and LYVE-1-positive lymphatic channels in the ciliary body had a distinct lumen, were negative for blood vessel endothelial cell marker CD34, and were surrounded by either discontinuous or no collagen IV-positive basement membrane. Cryo-immunogold electron microscopy confirmed the presence D2-40-immunoreactivity in lymphatic endothelium in the human ciliary body. Fluorescent nanospheres injected into the anterior chamber of the sheep eye were detected in LYVE-1-positive channels of the ciliary body 15, 30, and 45 min following injection. Four hours following intracameral injection, Iodine-125 radio-labeled human serum albumin injected into the sheep eye (n = 5) was drained preferentially into cervical, retropharyngeal, submandibular and preauricular lymph nodes in the head and neck region compared to reference popliteal lymph nodes (P human ciliary body, and that fluid and solutes flow at least partially through this system. The discovery of a uveolymphatic pathway in the eye is novel and highly relevant to studies of glaucoma and other eye diseases.

  14. Structural and Biochemical Analyses of Choroidal Thickness in Human Donor Eyes

    Science.gov (United States)

    Sohn, Elliott H.; Khanna, Aditi; Tucker, Budd A.; Abràmoff, Michael D.; Stone, Edwin M.; Mullins, Robert F.

    2014-01-01

    Purpose. The choroid plays a vital role in the health of the outer retina. While measurements of choroid using optical coherence tomography show altered thickness in aging and macular disease, detailed histopathologic and proteomic analyses are lacking. In this study we sought to evaluate biochemical differences in human donor eyes between very thin and thick choroids. Methods. One hundred forty-one eyes from 104 donors (mean age ± standard deviation, 81.5 ± 12.2) were studied. Macular sections were collected, and the distance between Bruch's membrane and the inner surface of the sclera was measured in control, early/dry age-related macular degeneration (AMD), neovascular AMD, and geographic atrophy eyes. Proteins from the RPE-choroid of eyes with thick and thin choroids were analyzed using two-dimensional electrophoresis and/or mass spectrometry. Two proteins with altered abundance were confirmed using Western blot analysis. Results. Donor eyes showed a normal distribution of thicknesses. Eyes with geographic atrophy had significantly thinner choroids than age-matched controls or early AMD eyes. Proteomic analysis showed higher levels of the serine protease SERPINA3 in thick choroids and increased levels of tissue inhibitor of metalloproteinases-3 (TIMP3) in thin choroids. Conclusions. Consistent with clinical imaging observations, geographic atrophy was associated with choroidal thinning. Biochemical data suggest an alteration in the balance between proteases and protease inhibitors in eyes that lie at the extremes of choroidal thickness. An improved understanding of the basic mechanisms associated with choroidal thinning may guide the development of new therapies for AMD. PMID:24519422

  15. Mathematical models of the dynamics of the human eye

    CERN Document Server

    Collins, Richard

    1980-01-01

    A rich and abundant literature has developed during the last half century dealing with mechanical aspects of the eye, mainly from clinical and, experimental points of view. For the most part, workers have attempted to shed light on the complex set of conditions known by the general term glaucoma. These conditions are characterised by an increase in intraocular pressure sufficient to cause de­ generation of the optic disc and concomitant defects in the visual field, which, if not controlled, lead to inevitable permanent blindness. In the United States alone, an estimated 50,000 persons are blind as a result of glaucoma, which strikes about 2% of the population over 40 years of age (Vaughan and Asbury, 1974). An understanding of the underlying mechanisms of glaucoma is hindered by the fact that elevated intraocular pressure, like a runny nose, is but a symptom which may have a variety of causes. Only by turning to the initial pathology can one hope to understand this important class of medical problems.

  16. A Proactive Approach of Robotic Framework for Making Eye Contact with Humans

    Directory of Open Access Journals (Sweden)

    Mohammed Moshiul Hoque

    2014-01-01

    Full Text Available Making eye contact is a most important prerequisite function of humans to initiate a conversation with others. However, it is not an easy task for a robot to make eye contact with a human if they are not facing each other initially or the human is intensely engaged his/her task. If the robot would like to start communication with a particular person, it should turn its gaze to that person and make eye contact with him/her. However, such a turning action alone is not enough to set up an eye contact phenomenon in all cases. Therefore, the robot should perform some stronger actions in some situations so that it can attract the target person before meeting his/her gaze. In this paper, we proposed a conceptual model of eye contact for social robots consisting of two phases: capturing attention and ensuring the attention capture. Evaluation experiments with human participants reveal the effectiveness of the proposed model in four viewing situations, namely, central field of view, near peripheral field of view, far peripheral field of view, and out of field of view.

  17. Goat′s eye integrated with a human cataractous lens: A training model for phacoemulsification

    Directory of Open Access Journals (Sweden)

    Sabyasachi Sengupta

    2015-01-01

    Full Text Available A relatively simple and inexpensive technique to train surgeons in phacoemulsification using a goat′s eye integrated with a human cataractous nucleus is described. The goat′s eye is placed on a bed of cotton within the lumen of a cylindrical container. This is then mounted on a rectangular thermocol so that the limbus is presented at the surgical field. After making a clear corneal entry with a keratome, the trainer makes a 5-5.5 mm continuous curvilinear capsulorhexis in the anterior lens capsule, creates a crater of adequate depth in the cortex and inserts the human nucleus within this crater in the goat′s capsular bag. The surgical wound is sutured, and the goat′s eye is ready for training. Creating the capsulorhexis with precision and making the crater of adequate depth to snugly accommodate the human nucleus are the most important steps to prevent excessive wobbling of the nucleus while training.

  18. Eye proprioception may provide real time eye position information.

    Science.gov (United States)

    Wang, Jing; Pan, Yujun

    2013-03-01

    Because of the frequency of eye movements, online knowledge of eye position is crucial for the accurate spatial perception and behavioral navigation. Both the internal monitoring signal (corollary discharge) of eye movements and the eye proprioception signal are thought to contribute to the localization of the eye position in the orbit. However, the functional role of these two eye position signals in spatial cognition has been disputed for more than a century. The predominant view proposes that the online analysis of eye position is exclusively provided by the corollary discharge signal, while the eye proprioception signal only plays a role in the long-term calibration of the oculomotor system. However, increasing evidence from recent behavioral and physiological studies suggests that the eye proprioception signal may play a role in the online monitoring of eye position. The purpose of this review is to discuss the feasibility and possible function of the eye proprioceptive signal for online monitoring of eye position.

  19. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Registry Medicare Physician Payment Meetings and Deadlines Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive ... Registry Medicare Physician Payment Meetings and Deadlines Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive ...

  20. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Deadlines Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive Surgery Museum of Vision Subspecialties Cataract/ ... Deadlines Ophthalmology Job Center Our Sites EyeWiki International Society of Refractive Surgery Museum of Vision Subspecialties Cataract/ ...

  1. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the ...

  2. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Emergency Relief EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Ophthalmology Job Center Our ... Emergency Relief EyeCare America Help IRIS Registry Medicare Physician Payment Meetings and Deadlines Ophthalmology Job Center Our ...

  3. About the Eye

    Medline Plus

    Full Text Available ... Optical Illusions Printables About the Eye Your eyes are made up of many different parts that work ... Media Information in Spanish (Información en español) Website, ... Office of Science Communications, Public Liaison, and Education. Technical questions about ...

  4. Eye-Tracking

    Directory of Open Access Journals (Sweden)

    Gabriela GROSSECK

    2006-01-01

    Full Text Available Eye-tracking: one of the newest and most efficient methods of improving on-line marketing communication is called eye-tracking. Marketers have borrowed this technique, usually used in psychological and medical research, in order to study web users with the help of a video camera incorporated in the monitor.

  5. Understanding pink eye

    Science.gov (United States)

    Pink eye (PE) is a physiological tuber disorder that can result in serious processing complications and storage losses. The earliest external symptoms consist of an ephemeral pinkish discoloration around tuber eyes, predominately at the bud end of the tuber. These pinkish areas can then develop into...

  6. Photorefraction of the Eye

    Science.gov (United States)

    Colicchia, Giuseppe; Wiesner, Hartmut; Zollman, Dean

    2015-01-01

    Photorefraction is a method to easily estimate the refractive state of the eye. The principle of photorefraction involves projecting light into the eye during flash photography and then examining the paths of light that emerge from the pupil after scattering on the back portion of the interior of the eyeball (fundus). We will explain the optical…

  7. Eye tracking social preferences

    NARCIS (Netherlands)

    Jiang, Ting; Potters, Jan; Funaki, Yukihiko

    We hypothesize that if people are motivated by a particular social preference, then choosing in accordance with this preference will lead to an identifiable pattern of eye movements. We track eye movements while subjects make choices in simple three-person distribution experiments. We characterize

  8. BullsEye

    DEFF Research Database (Denmark)

    Klokmose, Clemens Nylandsted; Kristensen, Janus Bager; Bagge, Rolf

    2014-01-01

    implemented primarily in shaders on the GPU. The techniques are realized in the BullsEye computer vision software. We demonstrate experimentally that BullsEye provides sub-pixel accuracy down to a tenth of a pixel, which is a significant improvement compared to the commonly used reacTIVision software....

  9. DISTANCE MEASURING MODELING AND ERROR ANALYSIS OF DUAL CCD VISION SYSTEM SIMULATING HUMAN EYES AND NECK

    Institute of Scientific and Technical Information of China (English)

    Wang Xuanyin; Xiao Baoping; Pan Feng

    2003-01-01

    A dual-CCD simulating human eyes and neck (DSHEN) vision system is put forward. Its structure and principle are introduced. The DSHEN vision system can perform some movements simulating human eyes and neck by means of four rotating joints, and realize precise object recognizing and distance measuring in all orientations. The mathematic model of the DSHEN vision system is built, and its movement equation is solved. The coordinate error and measure precision affected by the movement parameters are analyzed by means of intersection measuring method. So a theoretic foundation for further research on automatic object recognizing and precise target tracking is provided.

  10. APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Kovesdi, C.; Spielman, Z.; LeBlanc, K.; Rice, B.

    2017-05-01

    An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collect and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.

  11. Importance of non-synonymous OCA2 variants in human eye colour prediction

    DEFF Research Database (Denmark)

    Andersen, Jeppe Dyrberg; Pietroni, Carlotta; Johansen, Peter

    2016-01-01

    in the promotor region of OCA2 (OMIM #611409). Nevertheless, many eye colors cannot be explained by only considering rs12913832:A>G. Methods: In this study, we searched for additional variants in OCA2 to explain human eye color by sequencing a 500 kbp region, encompassing OCA2 and its promotor region. Results: We......Background: The color of the eyes is one of the most prominent phenotypes in humans and it is often used to describe the appearance of an individual. The intensity of pigmentation in the iris is strongly associated with one single-nucleotide polymorphism (SNP), rs12913832:A>G that is located...... identified three nonsynonymous OCA2 variants as important for eye color, including rs1800407:G>A (p.Arg419Gln) and two variants, rs74653330:A>T (p.Ala481Thr) and rs121918166:G>A (p.Val443Ile), not previously described as important for eye color variation. It was shown that estimated haplotypes consisting...

  12. Controlled delivery of antiangiogenic drug to human eye tissue using a MEMS device

    KAUST Repository

    Pirmoradi, Fatemeh Nazly

    2013-01-01

    We demonstrate an implantable MEMS drug delivery device to conduct controlled and on-demand, ex vivo drug transport to human eye tissue. Remotely operated drug delivery to human post-mortem eyes was performed via a MEMS device. The developed curved packaging cover conforms to the eyeball thereby preventing the eye tissue from contacting the actuating membrane. By pulsed operation of the device, using an externally applied magnetic field, the drug released from the device accumulates in a cavity adjacent to the tissue. As such, docetaxel (DTX), an antiangiogenic drug, diffuses through the eye tissue, from sclera and choroid to retina. DTX uptake by sclera and choroid were measured to be 1.93±0.66 and 7.24±0.37 μg/g tissue, respectively, after two hours in pulsed operation mode (10s on/off cycles) at 23°C. During this period, a total amount of 192 ng DTX diffused into the exposed tissue. This MEMS device shows great potential for the treatment of ocular posterior segment diseases such as diabetic retinopathy by introducing a novel way of drug administration to the eye. © 2013 IEEE.

  13. Dose conversion coefficients for neutron exposure to the lens of the human eye

    Energy Technology Data Exchange (ETDEWEB)

    Manger, Ryan P [ORNL; Bellamy, Michael B [ORNL; Eckerman, Keith F [ORNL

    2011-01-01

    Dose conversion coefficients for the lens of the human eye have been calculated for neutron exposure at energies from 1 x 10{sup -9} to 20 MeV and several standard orientations: anterior-to-posterior, rotational and right lateral. MCNPX version 2.6.0, a Monte Carlo-based particle transport package, was used to determine the energy deposited in the lens of the eye. The human eyeball model was updated by partitioning the lens into sensitive and insensitive volumes as the anterior portion (sensitive volume) of the lens being more radiosensitive and prone to cataract formation. The updated eye model was used with the adult UF-ORNL mathematical phantom in the MCNPX transport calculations.

  14. Coherent fiber optic sensor for early detection of cataractogenesis in a human eye lens

    Science.gov (United States)

    Dhadwal, Harbans S.; Ansari, Rafat R.; Dellavecchia, Michael A.

    1993-01-01

    A lensless backscatter fiber optic probe is used to measure the size distribution of protein molecules inside an excised, but intact, human eye lens. The fiber optic probe, about 5 mm in diameter, can be positioned arbitrarily close to the anterior surface of the eye; it is a trans-receiver, which delivers a Gaussian laser beam into a small region inside the lens and provides a coherent detection of the laser light scattered by the protein molecules in the backward direction. Protein sizes determined from the fast and slow diffusion coefficients show good correlation with the age of the lens and cataractogenesis.

  15. [THE STRUCTURE OF LYMPHATIC CAPILLARIES OF THE CILIARY BODY OF THE HUMAN EYE].

    Science.gov (United States)

    Borodin, Yu I; Bgatova, N P; Chernykh, V V; Trunov, A N; Pozhidayeva, A A; Konenkov, V I

    2015-01-01

    Using light microscopy, immunohistochemistry and electron microscopy, the structural organization of interstitial spaces and vessels of the ciliary body of the human eye (n = 5) were studied. The ciliary body was found to contain wide interstitial spaces--tissue clefts bound by collagen fibers and fibroblasts. Organ-specific lymphatic capillaries were also demonstrated in the ciliary body. According to the present findings and the lymphatic region concept, the first 2 elements of the lymphatic region of the eye were described: tissue clefts--prelymphatics and lymphatic capillaries of the ciliary body. The third element of the lymphatic region are the lymph nodes of the head and neck.

  16. Human Response to Ductless Personalised Ventilation: Impact of Air Movement, Temperature and Cleanness on Eye Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Fillon, Maelys; Bivolarova, Maria;

    2013-01-01

    The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation (DV) was studied in relation to peoples’ health, comfort and performance. This paper presents results on the impact of room air temperature, using of DPV and local air filtration on eye blink...... rate and tear film quality. In a test room with DV and six workstations 30 human subjects were exposed for four hours to each of the following 5 experimental conditions: 23 °C and DV only, 23 °C and DPV with air filter, 29 °C and DV only, 29 °C and DPV, and 29 °C and DPV with air filter. At warm...... environment facially applied individually controlled air movement of room air, with or without local filtering, did not have significant impact on eye blink frequency and tear film quality. The local air movement and air cleaning resulted in increased eye blinking frequency and improvement of tear film...

  17. A study of artificial eyes for the measurement of precision in eye-trackers.

    Science.gov (United States)

    Wang, Dong; Mulvey, Fiona B; Pelz, Jeff B; Holmqvist, Kenneth

    2016-07-06

    The precision of an eye-tracker is critical to the correct identification of eye movements and their properties. To measure a system's precision, artificial eyes (AEs) are often used, to exclude eye movements influencing the measurements. A possible issue, however, is that it is virtually impossible to construct AEs with sufficient complexity to fully represent the human eye. To examine the consequences of this limitation, we tested currently used AEs from three manufacturers of eye-trackers and compared them to a more complex model, using 12 commercial eye-trackers. Because precision can be measured in various ways, we compared different metrics in the spatial domain and analyzed the power-spectral densities in the frequency domain. To assess how precision measurements compare in artificial and human eyes, we also measured precision using human recordings on the same eye-trackers. Our results show that the modified eye model presented can cope with all eye-trackers tested and acts as a promising candidate for further development of a set of AEs with varying pupil size and pupil-iris contrast. The spectral analysis of both the AE and human data revealed that human eye data have different frequencies that likely reflect the physiological characteristics of human eye movements. We also report the effects of sample selection methods for precision calculations. This study is part of the EMRA/COGAIN Eye Data Quality Standardization Project.

  18. Two eyes, one vision: binocular motion perception in human visual cortex

    NARCIS (Netherlands)

    Barendregt, M.

    2016-01-01

    An important aspect of human vision is the fact that it is binocular, i.e. that we have two eyes. As a result, the brain nearly always receives two slightly different images of the same visual scene. Yet, we only perceive a single image and thus our brain has to actively combine the binocular visual

  19. Two eyes, one vision: binocular motion perception in human visual cortex

    NARCIS (Netherlands)

    Barendregt, M.|info:eu-repo/dai/nl/371576792

    2016-01-01

    An important aspect of human vision is the fact that it is binocular, i.e. that we have two eyes. As a result, the brain nearly always receives two slightly different images of the same visual scene. Yet, we only perceive a single image and thus our brain has to actively combine the binocular visual

  20. Relation between Local Acoustic Parameters and Protein Distribution in Human and Porcine Eye Lenses

    NARCIS (Netherlands)

    Korte, de C.L.; Steen, van der A.F.W.; Thijssen, J.M.; Duindam, J.J.; Otto, Cees; Puppels, G.J.

    1994-01-01

    The purpose of this study is to characterize the eye lens (human, porcine) by acoustic measurements and to investigate whether relations exist with the local protein content. The acoustic measurements were performed with a 'scanning acoustic microscope' (SAM), operating at a frequency of 20 MHz. At

  1. Towards a human eye behavior model by applying Data Mining Techniques on Gaze Information from IEC

    CERN Document Server

    Pallez, Denis; Baccino, Thierry

    2008-01-01

    In this paper, we firstly present what is Interactive Evolutionary Computation (IEC) and rapidly how we have combined this artificial intelligence technique with an eye-tracker for visual optimization. Next, in order to correctly parameterize our application, we present results from applying data mining techniques on gaze information coming from experiments conducted on about 80 human individuals.

  2. Magnetic eye tracking in mice.

    Science.gov (United States)

    Payne, Hannah L; Raymond, Jennifer L

    2017-09-05

    Eye movements provide insights about a wide range of brain functions, from sensorimotor integration to cognition; hence, the measurement of eye movements is an important tool in neuroscience research. We describe a method, based on magnetic sensing, for measuring eye movements in head-fixed and freely moving mice. A small magnet was surgically implanted on the eye, and changes in the magnet angle as the eye rotated were detected by a magnetic field sensor. Systematic testing demonstrated high resolution measurements of eye position of eye tracking offers several advantages over the well-established eye coil and video-oculography methods. Most notably, it provides the first method for reliable, high-resolution measurement of eye movements in freely moving mice, revealing increased eye movements and altered binocular coordination compared to head-fixed mice. Overall, magnetic eye tracking provides a lightweight, inexpensive, easily implemented, and high-resolution method suitable for a wide range of applications.

  3. What Is Dry Eye?

    Medline Plus

    Full Text Available ... vision in the morning? Jun 12, 2017 Can lupus affect my vision? May 27, 2017 Is stopping ... Answers Free Newsletter Get ophthalmologist-reviewed tips and information about eye health and preserving your vision. Privacy ...

  4. Anatomy of the Eye

    Science.gov (United States)

    ... Conditions Frequently Asked Questions Español Condiciones Chinese Conditions Anatomy of the Eye En Español Read in Chinese External (Extraocular) Anatomy Extraocular Muscles: There are six muscles that are ...

  5. Eye Disease and Development

    DEFF Research Database (Denmark)

    Andersen, Thomas Barnebeck; Dalgaard, Carl-Johan Lars; Selaya, Pablo

    This research advances the hypothesis that cross-country variation in the historical incidence of eye disease has influenced the current global distribution of per capita income. The theory is that pervasive eye disease diminished the incentive to accumulate skills, thereby delaying the fertility...... transition and the take-off to sustained economic growth. In order to estimate the influence from eye disease incidence empirically, we draw on an important fact from the field of epidemiology: Exposure to solar ultraviolet B radiation (UVB-R) is an underlying determinant of several forms of eye disease...... are robust to the inclusion of an extensive set of climate and geography controls. Moreover, using a global data set on economic activity for all terrestrial grid cells we show that the link between UVB-R and economic development survives the inclusion of country fixed effect....

  6. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., Scientific Director David ...

  7. About the Eye

    Medline Plus

    Full Text Available ... of visual function, preservation of sight, and the special health problems and requirements of the blind.” News & ... Emily Y. Chew, M.D., Deputy Clinical Director Education Programs National Eye Health Education Program (NEHEP) Diabetic ...

  8. Eyes, Bulging (Proptosis)

    Science.gov (United States)

    ... a disorder causing overactivity of the thyroid gland ( hyperthyroidism ). Bulging eyes are not the same as prominent ... or pain Whether the person has symptoms of hyperthyroidism, such as inability to tolerate heat, increased sweating, ...

  9. What Is Dry Eye?

    Medline Plus

    Full Text Available ... How do tears work? When you blink, a film of tears spreads over the eye. This keeps the eye’s surface smooth and clear. The tear film is important for good vision. The tear film ...

  10. About the Eye

    Medline Plus

    Full Text Available ... about each part of your eye and what it does. Macula (MACK-yoo-luh) is the small, ... area of the retina needed for central vision. It contains the fovea. Lens is the clear part ...

  11. What Is Eye Cancer?

    Science.gov (United States)

    ... melanomas. Melanomas develop from pigment-making cells called melanocytes . When melanoma develops in the eye, it is ... cells make the same kind of pigment as melanocytes in the skin, so it’s not surprising that ...

  12. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Find an Ophthalmologist Advanced ...

  13. About the Eye

    Medline Plus

    Full Text Available ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... Fellowships NEI Summer Intern Program Diversity In Vision Research & Ophthalmology (DIVRO) Student Training Programs To search for ...

  14. Sports and Your Eyes

    Science.gov (United States)

    ... may put you at high risk for eye injuries. Baseball Basketball Water Sports Boxing Hockey Paintball Racquetball Softball Squash Fencing Lacrosse Wrestling Football Golf Badminton Soccer Tennis Fishing Bicycling Gymnastics Track ...

  15. Diabetic Eye Problems

    Science.gov (United States)

    ... damage your eyes. The most common problem is diabetic retinopathy. It is a leading cause of blindness ... You need a healthy retina to see clearly. Diabetic retinopathy damages the tiny blood vessels inside your ...

  16. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Academy Publications EyeNet Ophthalmology Information for: International Ophthalmologists Media Medical Students Patients and Public Technicians and Nurses ...

  17. About the Eye

    Medline Plus

    Full Text Available ... NEI Women Scientists Advisory Committee (WSAC) Board of Scientific Counselors National Advisory Eye Council (NAEC) Donating to ... Grants and Funding Extramural Research Division of Extramural Science Programs Division of Extramural Activities Extramural Contacts NEI ...

  18. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Eye May 03, 2012 Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the Academy Jobs at the Academy Financial Relationships with Industry Medical ...

  19. The ageing eye

    African Journals Online (AJOL)

    2007-10-11

    Oct 11, 2007 ... With an increasing elderly population, age-related eye diseases are becoming the leading causes of ... and social health and overall quality of life. Enormous strides are ..... hip fractures, accidents and depression. Conclusion.

  20. Multimodal eye recognition

    Science.gov (United States)

    Zhou, Zhi; Du, Yingzi; Thomas, N. L.; Delp, Edward J., III

    2010-04-01

    Multimodal biometrics use more than one means of biometric identification to achieve higher recognition accuracy, since sometimes a unimodal biometric is not good enough used to do identification and classification. In this paper, we proposed a multimodal eye recognition system, which can obtain both iris and sclera patterns from one color eye image. Gabor filter and 1-D Log-Gabor filter algorithms have been applied as the iris recognition algorithms. In sclera recognition, we introduced automatic sclera segmentation, sclera pattern enhancement, sclera pattern template generation, and sclera pattern matching. We applied kernelbased matching score fusion to improve the performance of the eye recognition system. The experimental results show that the proposed eye recognition method can achieve better performance compared to unimodal biometric identification, and the accuracy of our proposed kernel-based matching score fusion method is higher than two classic linear matching score fusion methods: Principal Component Analysis (PCA) and Linear Discriminant Analysis (LDA).

  1. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Dry Eye Symptoms Related Ask an Ophthalmologist Answers Can a six-month dissolvable punctal plug be removed ... insert a permanent punctal plug? Sep 12, 2017 Can you explain why I have halos and blurry ...

  2. Eye Injuries in Construction

    Science.gov (United States)

    ... from a power tool (like a drill or wheel) , OR ! If your eye is cut or punctured : • ... CIO: CPWR, Suite 1000, 8484 Georgia Ave., Silver Spring, MD 20910. (Edward C. Sullivan is president of ...

  3. Applied eye tracking research

    NARCIS (Netherlands)

    Jarodzka, Halszka

    2011-01-01

    Jarodzka, H. (2010, 12 November). Applied eye tracking research. Presentation and Labtour for Vereniging Gewone Leden in oprichting (VGL i.o.), Heerlen, The Netherlands: Open University of the Netherlands.

  4. What Is Dry Eye?

    Medline Plus

    Full Text Available ... Pediatric Ophthalmology Education Center Oculofacial Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide ... What Is Dry Eye? Written By: Kierstan Boyd ...

  5. About the Eye

    Medline Plus

    Full Text Available ... about each part of your eye and what it does. Macula (MACK-yoo-luh) is the small, ... area of the retina needed for central vision. It contains the fovea. Lens is the clear part ...

  6. Toxoplasmosis (and the Eye)

    Science.gov (United States)

    ... cat litter boxes, cat feces, sandboxes, and any insects exposed to cat feces (cockroaches, flies, etc.). Immunocompromised ... rash. Eye symptoms vary, but may include blurred vision or floaters during active disease. The diagnosis can ...

  7. About the Eye

    Medline Plus

    Full Text Available ... programs with respect to blinding eye diseases, visual disorders, mechanisms of visual function, preservation of sight, and the special health problems and ... Health Information Frequently asked questions ...

  8. Applied eye tracking research

    NARCIS (Netherlands)

    Jarodzka, Halszka

    2011-01-01

    Jarodzka, H. (2010, 12 November). Applied eye tracking research. Presentation and Labtour for Vereniging Gewone Leden in oprichting (VGL i.o.), Heerlen, The Netherlands: Open University of the Netherlands.

  9. Eye Dominance Predicts fMRI Signals in Human Retinotopic Cortex

    OpenAIRE

    Mendola, Janine D; Conner, Ian P.

    2006-01-01

    There have been many attempts to define eye dominance in normal subjects, but limited consensus exists, and relevant physiological data is scarce. In this study, we consider two different behavioral methods for assignment of eye dominance, and how well they predict fMRI signals evoked by monocular stimulation. Sighting eye dominance was assessed with two standard tests, the Porta Test, and a ‘hole in hand’ variation of the Miles Test. Acuity dominance was tested with a standard eye chart and ...

  10. An eye model for uncalibrated eye gaze estimation under variable head pose

    Science.gov (United States)

    Hnatow, Justin; Savakis, Andreas

    2007-04-01

    Gaze estimation is an important component of computer vision systems that monitor human activity for surveillance, human-computer interaction, and various other applications including iris recognition. Gaze estimation methods are particularly valuable when they are non-intrusive, do not require calibration, and generalize well across users. This paper presents a novel eye model that is employed for efficiently performing uncalibrated eye gaze estimation. The proposed eye model was constructed from a geometric simplification of the eye and anthropometric data about eye feature sizes in order to circumvent the requirement of calibration procedures for each individual user. The positions of the two eye corners and the midpupil, the distance between the two eye corners, and the radius of the eye sphere are required for gaze angle calculation. The locations of the eye corners and midpupil are estimated via processing following eye detection, and the remaining parameters are obtained from anthropometric data. This eye model is easily extended to estimating eye gaze under variable head pose. The eye model was tested on still images of subjects at frontal pose (0 °) and side pose (34 °). An upper bound of the model's performance was obtained by manually selecting the eye feature locations. The resulting average absolute error was 2.98 ° for frontal pose and 2.87 ° for side pose. The error was consistent across subjects, which indicates that good generalization was obtained. This level of performance compares well with other gaze estimation systems that utilize a calibration procedure to measure eye features.

  11. Modern sports eye injuries.

    Science.gov (United States)

    Capão Filipe, J A; Rocha-Sousa, A; Falcão-Reis, F; Castro-Correia, J

    2003-11-01

    To determine the severity and long term sequelae of eye injuries caused by modern sports that could be responsible for significant ocular trauma in the future. Prospective observational study of 24 (25 eyes) athletes with sports related ocular injuries from health clubs, war games, adventure, radical and new types of soccer, presenting to an eye emergency department between 1992 and 2002 (10 years). Modern sports were responsible for 8.3% of the 288 total sports eye injuries reported. Squash (29.2%) was the most common cause, followed by paintball (20.8%) and motocross (16.6%). The most common diagnosis during the follow up period was retinal breaks (20%). 18 (75%) patients sustained a severe injury. The final visual acuity remained <20/100 in two paintball players. Ocular injuries resulting from modern sports are often severe. Adequate instruction of the participants in the games, proper use of eye protectors, and a routine complete ophthalmological examination after an eye trauma should be mandatory.

  12. Thermal behavior of human eye in relation with change in blood perfusion, porosity, evaporation and ambient temperature.

    Science.gov (United States)

    Rafiq, Aasma; Khanday, M A

    2016-12-01

    Extreme environmental and physiological conditions present challenges for thermal processes in body tissues including multi-layered human eye. A mathematical model has been formulated in this direction to study the thermal behavior of the human eye in relation with the change in blood perfusion, porosity, evaporation and environmental temperatures. In this study, a comprehensive thermal analysis has been performed on the multi-layered eye using Pennes' bio-heat equation with appropriate boundary and interface conditions. The variational finite element method and MATLAB software were used for the solution purpose and simulation of the results. The thermoregulatory effect due to blood perfusion rate, porosity, ambient temperature and evaporation at various regions of human eye was illustrated mathematically and graphically. The main applications of this model are associated with the medical sciences while performing laser therapy and other thermoregulatory investigation on human eye.

  13. The effect of human image in B2C website design: an eye-tracking study

    Science.gov (United States)

    Wang, Qiuzhen; Yang, Yi; Wang, Qi; Ma, Qingguo

    2014-09-01

    On B2C shopping websites, effective visual designs can bring about consumers' positive emotional experience. From this perspective, this article developed a research model to explore the impact of human image as a visual element on consumers' online shopping emotions and subsequent attitudes towards websites. This study conducted an eye-tracking experiment to collect both eye movement data and questionnaire data to test the research model. Questionnaire data analysis showed that product pictures combined with human image induced positive emotions among participants, thus promoting their attitudes towards online shopping websites. Specifically, product pictures with human image first produced higher levels of image appeal and perceived social presence, thus stimulating higher levels of enjoyment and subsequent positive attitudes towards the websites. Moreover, a moderating effect of product type was demonstrated on the relationship between the presence of human image and the level of image appeal. Specifically, human image significantly increased the level of image appeal when integrated in entertainment product pictures while this relationship was not significant in terms of utilitarian products. Eye-tracking data analysis further supported these results and provided plausible explanations. The presence of human image significantly increased the pupil size of participants regardless of product types. For entertainment products, participants paid more attention to product pictures integrated with human image whereas for utilitarian products more attention was paid to functional information of products than to product pictures no matter whether or not integrated with human image.

  14. Transverse chromatic aberration across the visual field of the human eye.

    Science.gov (United States)

    Winter, Simon; Sabesan, Ramkumar; Tiruveedhula, Pavan; Privitera, Claudio; Unsbo, Peter; Lundström, Linda; Roorda, Austin

    2016-11-01

    The purpose of this study was to measure the transverse chromatic aberration (TCA) across the visual field of the human eye objectively. TCA was measured at horizontal and vertical field angles out to ±15° from foveal fixation in the right eye of four subjects. Interleaved retinal images were taken at wavelengths 543 nm and 842 nm in an adaptive optics scanning laser ophthalmoscope (AOSLO). To obtain true measures of the human eye's TCA, the contributions of the AOSLO system's TCA were measured using an on-axis aligned model eye and subtracted from the ocular data. The increase in TCA was found to be linear with eccentricity, with an average slope of 0.21 arcmin/degree of visual field angle (corresponding to 0.41 arcmin/degree for 430 nm to 770 nm). The absolute magnitude of ocular TCA varied between subjects, but was similar to the resolution acuity at 10° in the nasal visual field, encompassing three to four cones. Therefore, TCA can be visually significant. Furthermore, for high-resolution imaging applications, whether visualizing or stimulating cellular features in the retina, it is important to consider the lateral displacements between wavelengths and the variation in blur over the visual field.

  15. From time series analysis to a biomechanical multibody model of the human eye

    Energy Technology Data Exchange (ETDEWEB)

    Pascolo, P. [Dipartimento di Ingegneria Civile, Universita di Udine, Udine (Italy); Dipartimento di Bioingegneria, CISM, Udine (Italy)], E-mail: paolo.pascolo@uniud.it; Carniel, R. [Dipartimento di Georisorse e Territorio, Universita di Udine, Udine (Italy)], E-mail: roberto.carniel@uniud.it

    2009-04-30

    A mechanical model of the human eye is presented aimed at estimating the level of muscular activation. The applicability of the model in the biomedical field is discussed. Human eye movements studied in the laboratory are compared with the ones produced by a virtual eye described in kinematical terms and subject to the dynamics of six actuators, as many as the muscular systems devoted to the eye motion control. The definition of an error function between the experimental and the numerical response and the application of a suitable law that links activation and muscular force are at the base of the proposed methodology. The aim is the definition of a simple conceptual tool that could help the specialist in the diagnosis of potential physiological disturbances of saccadic and nystagmic movements but can also be extended in a second phase when more sophisticated data become available. The work is part of a collaboration between the Functional Mechanics Laboratory of the University and the Neurophysiopatology Laboratory of the 'S. Maria della Misericordia' Hospital in Udine, Italy.

  16. Effects of aqueous humor hydrodynamics on human eye heat transfer under external heat sources.

    Science.gov (United States)

    Tiang, Kor L; Ooi, Ean H

    2016-08-01

    The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-dimensional model of the human eye is developed to investigate the effects AH hydrodynamics have on the human eye temperature under exposure to external heat sources. If the effects of AH flow are negligible, then future models can be developed without taking them into account, thus simplifying the modeling process. Two types of external thermal loads are considered; volumetric and surface irradiation. Results showed that heat convection due to AH flow contributes to nearly 95% of the total heat flow inside the anterior chamber. Moreover, the circulation inside the anterior chamber can cause an upward shift of the location of hotspot. This can have significant consequences to our understanding of heat-induced cataractogenesis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Simulated human eye retina adaptive optics imaging system based on a liquid crystal on silicon device

    Institute of Scientific and Technical Information of China (English)

    Jiang Bao-Guang; Cao Zhao-Liang; Mu Quan-Quan; Hu Li-Fa; Li Chao; Xuan Li

    2008-01-01

    In order to obtain a clear image of the retina of model eye, an adaptive optics system used to correct the wave-front error is introduced in this paper. The spatial light modulator that we use here is a liquid crystal on a silicon device instead of a conversional deformable mirror. A paper with carbon granule is used to simulate the retina of human eye. The pupil size of the model eye is adjustable (3-7 mm). A Shack-Hartman wave-front sensor is used to detect the wave-front aberration. With this construction, a value of peak-to-valley is achieved to be 0.086 λ, where A is wavelength.The modulation transfer functions before and after corrections are compared. And the resolution of this system after correction (691p/m) is very close to the diffraction limit resolution. The carbon granule on the white paper which has a size of 4.7μm is seen clearly. The size of the retina cell is between 4 and 10 μm. So this system has an ability to image the human eye's retina.

  18. Elastic modulus of orbicularis oculi muscle in normal humans, humans with Graves' eye disease, and cynomolgus monkeys.

    Science.gov (United States)

    Oestreicher, J H; Frueh, B R

    1995-06-01

    We built an experimental apparatus to investigate the passive elastic characteristics of orbicularis oculi muscle and examined specimens from normal humans, humans with stable Graves' eye disease, and cynomolgus monkeys. Stress-strain curves were determined and found to be exponential. The elastic modulus (Young's modulus), analogous to the stiffness of the material, was calculated as a function of strain. Elastic modulus as a function of instantaneous stress was linear. Monkey elastic modulus values were determined, but did not allow meaningful interspecies comparison because of the small sample size. No significant difference was found between normal humans and humans with Graves' eye disease with respect to elastic modulus values.

  19. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study

    NARCIS (Netherlands)

    Barsingerhorn, A.D.; Boonstra, F.N.; Goossens, H.H.L.M.

    2017-01-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different

  20. [Detection of carotenoids in the vitreous body of the human eye during prenatal development].

    Science.gov (United States)

    Iakovleva, M A; Panova, I G; Fel'dman, T B; Zak, P P; Tatikolov, A S; Sukhikh, G T; Ostrovskiĭ, M A

    2007-01-01

    Carotenoids were found for the first time in the vitreous body of human eye during the fetal period from week 15 until week 28. Their maximum content was timed to week 16-22. No carotenoids were found the vitreous body of 31-week fetuses, as well as adult humans, which corresponds to the published data. It was shown using HPLC that chromatographic characteristics of these carotenoids correspond to those of lutein and zeaxanthin, characteristic pigments of the retinal yellow macula.

  1. Edge detection of iris of the eye for human biometric identification system

    Directory of Open Access Journals (Sweden)

    Kateryna O. Tryfonova

    2015-03-01

    Full Text Available Method of human biometric identification by iris of the eye is considered as one of the most accurate and reliable methods of identification. Aim of the research is to solve the problem of edge detection of digital image of the human eye iris to be able to implement human biometric identification system by means of mobile device. To achieve this aim the algorithm of edge detection by Canny is considered in work. It consists of the following steps: smoothing, finding gradients, non-maximum suppression, double thresholding with hysteresis. The software implementation of the Canny algorithm is carried out for the Android mobile platform with the use of high level programming language Java.

  2. Effect of human milk as a treatment for dry eye syndrome in a mouse model

    Science.gov (United States)

    Diego, Jose L.; Bidikov, Luke; Pedler, Michelle G.; Kennedy, Jeffrey B.; Quiroz-Mercado, Hugo; Gregory, Darren G.; Petrash, J. Mark

    2016-01-01

    Purpose Dry eye syndrome (DES) affects millions of people worldwide. Homeopathic remedies to treat a wide variety of ocular diseases have previously been documented in the literature, but little systematic work has been performed to validate the remedies’ efficacy using accepted laboratory models of disease. The purpose of this study was to evaluate the efficacy of human milk and nopal cactus (prickly pear), two widely used homeopathic remedies, as agents to reduce pathological markers of DES. Methods The previously described benzalkonium chloride (BAK) dry eye mouse model was used to study the efficacy of human milk and nopal cactus (prickly pear). BAK (0.2%) was applied to the mouse ocular surface twice daily to induce dry eye pathology. Fluorescein staining was used to verify that the animals had characteristic signs of DES. After induction of DES, the animals were treated with human milk (whole and fat-reduced), nopal, nopal extract derivatives, or cyclosporine four times daily for 7 days. Punctate staining and preservation of corneal epithelial thickness, measured histologically at the end of treatment, were used as indices of therapeutic efficacy. Results Treatment with BAK reduced the mean corneal epithelial thickness from 36.77±0.64 μm in the control mice to 21.29±3.2 μm. Reduction in corneal epithelial thickness was largely prevented by administration of whole milk (33.2±2.5 μm) or fat-reduced milk (36.1±1.58 μm), outcomes that were similar to treatment with cyclosporine (38.52±2.47 μm), a standard in current dry eye therapy. In contrast, crude or filtered nopal extracts were ineffective at preventing BAK-induced loss of corneal epithelial thickness (24.76±1.78 μm and 27.99±2.75 μm, respectively), as were solvents used in the extraction of nopal materials (26.53±1.46 μm for ethyl acetate, 21.59±5.87 μm for methanol). Epithelial damage, as reflected in the punctate scores, decreased over 4 days of treatment with whole and fat

  3. Category processing and the human likeness dimension of the Uncanny Valley Hypothesis: Eye-tracking data

    Directory of Open Access Journals (Sweden)

    Marcus eCheetham

    2013-03-01

    Full Text Available The Uncanny Valley Hypothesis (Mori, 1970 predicts that perceptual difficulty distinguishing between a humanlike object (e.g., lifelike prosthetic hand, mannequin and its human counterpart evokes negative affect. Research has focussed on affect, with inconsistent results, but little is known about how objects along the hypothesis’ dimension of human likeness (DHL are actually perceived. This study used morph continua based on human and highly realistic computer-generated (avatar faces to represent the DHL. Total number and dwell time of fixations to facial features were recorded while participants (N=60 judged avatar vs. human category membership of the faces in a forced choice categorisation task. Fixation and dwell data confirmed the face feature hierarchy (eyes, nose and mouth in this order of importance across the DHL. There were no further findings for fixation. A change in the relative importance of these features was found for dwell time, with greater preferential processing of eyes and mouth of categorically ambiguous faces compared with unambiguous avatar faces. There were no significant differences between ambiguous and human faces. These findings applied for men and women, though women generally dwelled more on the eyes to the disadvantage of the nose. The mouth was unaffected by gender. In summary, the relative importance of facial features changed on the DHL’s nonhuman side as a function of categorisation ambiguity. This change was indicated by dwell time only, suggesting greater depth of perceptual processing of the eyes and mouth of ambiguous faces compared with these features in unambiguous avatar faces.

  4. Distribution of the neuro-regulatory peptide galanin in the human eye.

    Science.gov (United States)

    Kaser-Eichberger, Alexandra; Trost, Andrea; Strohmaier, Clemens; Bogner, Barbara; Runge, Christian; Bruckner, Daniela; Hohberger, Bettina; Jünemann, Anselm; Kofler, Barbara; Reitsamer, Herbert A; Schrödl, Falk

    2016-11-25

    Galanin (GAL) is a neuro-regulatory peptide involved in many physiological and pathophysiological processes. While data of GAL origin/distribution in the human eye are rather fragmentary and since recently the presence of GAL-receptors in the normal human eye has been reported, we here systematically search for sources of ocular GAL in the human eye. Human eyes (n=14) were prepared for single- and double-immunohistochemistry of GAL and neurofilaments (NF). Cross- and flat-mount sections were achieved; confocal laser-scanning microscopy was used for documentation. In the anterior eye, GAL-immunoreactivity (GAL-IR) was detected in basal layers of corneal epithelium, endothelium, and in nerve fibers and keratinocytes of the corneal stroma. In the conjunctiva, GAL-IR was seen throughout all epithelial cell layers. In the iris, sphincter and dilator muscle and endothelium of iris vessels displayed GAL-IR. It was also detected in stromal cells containing melanin granules, while these were absent in others. In the ciliary body, ciliary muscle and pigmented as well as non-pigmented ciliary epithelium displayed GAL-IR. In the retina, GAL-IR was detected in cells associated with the ganglion cell layer, and in endothelial cells of retinal blood vessels. In the choroid, nerve fibers of the choroidal stroma as well as fibers forming boutons and surrounding choroidal blood vessels displayed GAL-IR. Further, the majority of intrinsic choroidal neurons were GAL-positive, as revealed by co-localization-experiments with NF, while a minority displayed NF- or GAL-IR only. GAL-IR was also detected in choroidal melanocytes, as identified by the presence of intracellular melanin-granules, as well as in cells lacking melanin-granules, most likely representing macrophages. GAL-IR was detected in numerous cells and tissues throughout the anterior and posterior eye and might therefore be an important regulatory peptide for many aspects of ocular control. Upcoming studies in diseased tissue

  5. Calibration of an eye oximeter with a dynamic eye phantom

    Science.gov (United States)

    Nabili, A.; Bardakci, D.; Helling, K.; Matyas, C.; Muro, S.; Ramella-Roman, J. C.

    2008-02-01

    Measurements of oxygen saturation and flow in the retina can yield information about the eye health and the onset of eye pathologies such as Diabetic Retinopathy. Recently we have realized an instrument capable of measuring oxygenation in the retina using six different wavelengths and capable of measuring blood flow using speckle-based techniques. The calibration of such instrument is particularly difficult due to the layered structure of the eye and the lack of alternative measurement techniques. For this purpose we have realized an in vitro model of the human eye. The artificial eye is composed of four layers: the retina vessels, the choroids, the retinal pigmented epithelium (RPE), and the sclera. The retina vessels are modeled with 150 μm tube connected to a micro-pump delivering 34 μl/min. The micro-tube, the pump, and a blood reservoir were connected in a closed circulatory system; blood oxygenation in the vessel could be modified using an external oxygen reservoir. The optical properties of all other layers were mimicked using titanium dioxide as a scatterer and ink as an absorber. The absorption coefficient μa and the scattering coefficient µs of these layers were independently measured using an integrating sphere. Absorption and scattering coefficient of all layers were modified before experimental measurements and a Monte Carlo program was finally used to model the experimental results.

  6. The effects of metamaterial on electromagnetic fields absorption characteristics of human eye tissues.

    Science.gov (United States)

    Gasmelseed, Akram; Yunus, Jasmy

    2014-01-01

    The interaction of a dipole antenna with a human eye model in the presence of a metamaterial is investigated in this paper. The finite difference time domain (FDTD) method with convolutional perfectly matched layer (CPML) formulation have been used. A three-dimensional anatomical model of the human eye with resolution of 1.25 mm × 1.25 mm × 1.25 mm was used in this study. The dipole antenna was driven by modulated Gaussian pulse and the numerical study is performed with dipole operating at 900 MHz. The analysis has been done by varying the size and value of electric permittivity of the metamaterial. By normalizing the peak SAR (1 g and 10 g) to 1 W for all examined cases, we observed how the SAR values are not affected by the different permittivity values with the size of the metamaterial kept fixed.

  7. Eye-hand Hybrid Gesture Recognition System for Human Machine Interface

    Directory of Open Access Journals (Sweden)

    N. R. Raajan

    2013-04-01

    Full Text Available Gesture Recognition has become a way for computers to recognise and understand human body language. They bridge the gap between machines and human beings and make the primitive interfaces like keyboards and mice redundant. This paper suggests a hybrid gesture recognition system for computer interface and wireless robot control. The real-time eye-hand gesture recognition system can be used for computer drawing, navigating cursors and simulating mouse clicks, playing games, controlling a wireless robot with commands and more. The robot illustrated in this paper is controlled by RF module. Playing a PING-PONG game has also been demonstrated using the gestures. The Haar cascade classifiers and template matching are used to detect eye gestures and convex hull for finding the defects and counting the number of fingers in the given region.

  8. Social interactions through the eyes of macaques and humans.

    Directory of Open Access Journals (Sweden)

    Richard McFarland

    Full Text Available Group-living primates frequently interact with each other to maintain social bonds as well as to compete for valuable resources. Observing such social interactions between group members provides individuals with essential information (e.g. on the fighting ability or altruistic attitude of group companions to guide their social tactics and choice of social partners. This process requires individuals to selectively attend to the most informative content within a social scene. It is unclear how non-human primates allocate attention to social interactions in different contexts, and whether they share similar patterns of social attention to humans. Here we compared the gaze behaviour of rhesus macaques and humans when free-viewing the same set of naturalistic images. The images contained positive or negative social interactions between two conspecifics of different phylogenetic distance from the observer; i.e. affiliation or aggression exchanged by two humans, rhesus macaques, Barbary macaques, baboons or lions. Monkeys directed a variable amount of gaze at the two conspecific individuals in the images according to their roles in the interaction (i.e. giver or receiver of affiliation/aggression. Their gaze distribution to non-conspecific individuals was systematically varied according to the viewed species and the nature of interactions, suggesting a contribution of both prior experience and innate bias in guiding social attention. Furthermore, the monkeys' gaze behavior was qualitatively similar to that of humans, especially when viewing negative interactions. Detailed analysis revealed that both species directed more gaze at the face than the body region when inspecting individuals, and attended more to the body region in negative than in positive social interactions. Our study suggests that monkeys and humans share a similar pattern of role-sensitive, species- and context-dependent social attention, implying a homologous cognitive mechanism of

  9. Comparing the accuracy of video-oculography and the scleral search coil system in human eye movement analysis.

    Science.gov (United States)

    Imai, Takao; Sekine, Kazunori; Hattori, Kousuke; Takeda, Noriaki; Koizuka, Izumi; Nakamae, Koji; Miura, Katsuyoshi; Fujioka, Hiromu; Kubo, Takeshi

    2005-03-01

    The measurement of eye movements in three dimensions is an important tool to investigate the human vestibular and oculomotor system. The primary methods for three dimensional eye movement measurement are the scleral search coil system (SSCS) and video-oculography (VOG). In the present study, we compare the accuracy of VOG with that of SSCS using an artificial eye. We then analyzed the Y (pitch) and Z (yaw) component of human eye movements during saccades, smooth pursuit and optokinetic nystagmus, and the X (roll) component of human eye movement during the torsional vestibulo-ocular reflex induced by rotation in normal subjects, using simultaneous VOG and SSCS measures. The coefficients of the linear relationship between the angle of a simulated eyeball and the angle measured by both VOG and SSCS was almost unity with y-intercepts close to zero for torsional (X), vertical (Y) and horizontal (Z) movements, indicating that the in vitro accuracy of VOG was similar to that of SSCS. The average difference between VOG and SSCS was 0.56 degrees , 0.78 degrees and 0.18 degrees for the X, Y and Z components of human eye movements, respectively. Both the in vitro and in vivo comparisons demonstrate that VOG has accuracy comparable to SSCS, and is a reliable method for measurement of three dimensions (3D) human eye movements.

  10. On the plausible association between environmental conditions and human eye damage.

    Science.gov (United States)

    Feretis, Elias; Theodorakopoulos, Panagiotis; Varotsos, Costas; Efstathiou, Maria; Tzanis, Christos; Xirou, Tzina; Alexandridou, Nancy; Aggelou, Michael

    2002-01-01

    The increase in solar ultraviolet radiation can have various direct and indirect effects on human health, like the incidence of ocular damage. Data of eye damage in residents of three suburban regions in Greece and in two groups of monks/nuns and fishermen are examined here. The statistics performed on these data provides new information about the plausible association between increased levels of solar ultraviolet radiation, air-pollution at ground level, and the development of ocular defects.

  11. Sensory eye irritation in humans exposed to mixtures of volatile organic compounds

    DEFF Research Database (Denmark)

    Hempel-Jørgensen, Anne Hempel; Kjærgaard, Søren K.; Mølhave, Lars;

    1999-01-01

    Eight subjects participated in a controlled eyes-only exposure study of human sensory irritation in ocular mucosal tissue. The authors investigated dose-response properties and the additive effects of three mixtures of volatile organic compounds. The dose-response relationships for these mixtures...... to as simple agonism. Finally, the authors addressed the comparability of two methods to measure sensory irritation intensity (visual analogue scale and a comparative scale). The results indicated that the two rating methods produced highly comparable results....

  12. Simple, Inexpensive Technique for High-Quality Smartphone Fundus Photography in Human and Animal Eyes

    OpenAIRE

    Haddock, Luis J.; Kim, David Y.; Shizuo Mukai

    2013-01-01

    Purpose. We describe in detail a relatively simple technique of fundus photography in human and rabbit eyes using a smartphone, an inexpensive app for the smartphone, and instruments that are readily available in an ophthalmic practice. Methods:. Fundus images were captured with a smartphone and a 20D lens with or without a Koeppe lens. By using the coaxial light source of the phone, this system works as an indirect ophthalmoscope that creates a digital image of the fundus. The application wh...

  13. Apnea-Induced Rapid Eye Movement Sleep Disruption Impairs Human Spatial Navigational Memory

    OpenAIRE

    Varga, Andrew W.; Kishi, Akifumi; Mantua, Janna; Lim, Jason; Koushyk, Viachaslau; Leibert, David P.; Osorio, Ricardo S.; David M. Rapoport; Ayappa, Indu

    2014-01-01

    Hippocampal electrophysiology and behavioral evidence support a role for sleep in spatial navigational memory, but the role of particular sleep stages is less clear. Although rodent models suggest the importance of rapid eye movement (REM) sleep in spatial navigational memory, a similar role for REM sleep has never been examined in humans. We recruited subjects with severe obstructive sleep apnea (OSA) who were well treated and adherent with continuous positive airway pressure (CPAP). Restric...

  14. Assessment of Thermal Dehydration Using the Human Eye: What is the Potential?

    Science.gov (United States)

    2012-01-01

    multifunctional neuroendocrine gland. Prog. Retin. Eye Res. 26, 239–262. Connors, B.W., 2009. Sensory transduction. In: Boron , W.F., Boulpaep, E.L. (Eds.), Medical ...relevant physiological basis for testing the merit of ocular measures for human hydration assessment and recent data indicate that Tosm and IOP may have...Rudolf Foundation Clinic, Vienna, Austria d Centre of Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria a r t

  15. What interests them in the pictures?--differences in eye-tracking between rhesus monkeys and humans.

    Science.gov (United States)

    Hu, Ying-Zhou; Jiang, Hui-Hui; Liu, Ci-Rong; Wang, Jian-Hong; Yu, Cheng-Yang; Carlson, Synnöve; Yang, Shang-Chuan; Saarinen, Veli-Matti; Rizak, Joshua D; Tian, Xiao-Guang; Tan, Hen; Chen, Zhu-Yue; Ma, Yuan-Ye; Hu, Xin-Tian

    2013-10-01

    Studies estimating eye movements have demonstrated that non-human primates have fixation patterns similar to humans at the first sight of a picture. In the current study, three sets of pictures containing monkeys, humans or both were presented to rhesus monkeys and humans. The eye movements on these pictures by the two species were recorded using a Tobii eye-tracking system. We found that monkeys paid more attention to the head and body in pictures containing monkeys, whereas both monkeys and humans paid more attention to the head in pictures containing humans. The humans always concentrated on the eyes and head in all the pictures, indicating the social role of facial cues in society. Although humans paid more attention to the hands than monkeys, both monkeys and humans were interested in the hands and what was being done with them in the pictures. This may suggest the importance and necessity of hands for survival. Finally, monkeys scored lower in eye-tracking when fixating on the pictures, as if they were less interested in looking at the screen than humans. The locations of fixation in monkeys may provide insight into the role of eye movements in an evolutionary context.

  16. Visual exploration patterns of human figures in action: an eye tracker study with art paintings.

    Science.gov (United States)

    Villani, Daniela; Morganti, Francesca; Cipresso, Pietro; Ruggi, Simona; Riva, Giuseppe; Gilli, Gabriella

    2015-01-01

    Art exploration is a complex process conditioned by factors at different levels and includes both basic visual principles and complex cognitive factors. The human figure is considered a critical factor attracting the attention in art painting. Using an eye-tracking methodology, the goal of this study was to explore different elements of the human figure performing an action (face and body parts in action) in complex social scenes characterized by different levels of social interaction between agents depicted in scenes (individual vs. social). The sample included 44 laypersons, and the stimuli consisted of 10 fine art paintings representing the figurative style of classical art. The results revealed different scanning patterns of the human figure elements related to the level of social interaction of agents depicted in the scene. The agents' face attracted eye movements in social interaction scenes while the agents' body parts attracted eye movements only when the agents were involved in individual actions. These processes were confirmed specifically in participants with high empathic abilities who became immediately fixated on faces to develop a mimetic engagement with other agents. Future studies integrating other measures would help confirm the results obtained and strengthen their implication for embodiment processes.

  17. Homology of the eyeless gene of Drosophila to the Small eye gene in mice and Aniridia in humans.

    Science.gov (United States)

    Quiring, R; Walldorf, U; Kloter, U; Gehring, W J

    1994-08-05

    A Drosophila gene that contains both a paired box and a homeobox and has extensive sequence homology to the mouse Pax-6 (Small eye) gene was isolated and mapped to chromosome IV in a region close to the eyeless locus. Two spontaneous mutations, ey2 and eyR, contain transposable element insertions into the cloned gene and affect gene expression, particularly in the eye primordia. This indicates that the cloned gene encodes ey. The finding that ey of Drosophila, Small eye of the mouse, and human Aniridia are encoded by homologous genes suggests that eye morphogenesis is under similar genetic control in both vertebrates and insects, in spite of the large differences in eye morphology and mode of development.

  18. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    Science.gov (United States)

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  19. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    Science.gov (United States)

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  20. Nutrients for the aging eye

    Directory of Open Access Journals (Sweden)

    Rasmussen HM

    2013-06-01

    Full Text Available Helen M Rasmussen,1 Elizabeth J Johnson2 1Educational Studies, Lesley University, Cambridge, MA, USA; 2Carotenoid and Health Laboratory, Jean Mayer US Department of Agriculture Human Nutrition Research Center on Aging at Tufts University, Boston, MA, USA Abstract: The incidence of age-related eye diseases is expected to rise with the aging of the population. Oxidation and inflammation are implicated in the etiology of these diseases. There is evidence that dietary antioxidants and anti-inflammatories may provide benefit in decreasing the risk of age-related eye disease. Nutrients of interest are vitamins C and E, β-carotene, zinc, lutein, zeaxanthin, and the omega-3 fatty acids eicosapentaenoic acid and docosahexaenoic acid. While a recent survey finds that among the baby boomers (45–65 years old, vision is the most important of the five senses, well over half of those surveyed were not aware of the important nutrients that play a key role in eye health. This is evident from a national survey that finds that intake of these key nutrients from dietary sources is below the recommendations or guidelines. Therefore, it is important to educate this population and to create an awareness of the nutrients and foods of particular interest in the prevention of age-related eye disease. Keywords: nutrition, aging, eye health

  1. A bird’s eye view of human language evolution

    Directory of Open Access Journals (Sweden)

    Robert eBerwick

    2012-04-01

    Full Text Available Comparative studies of linguistic faculties in animals pose an evolutionary paradox: language involves certain perceptual and motor abilities, but it is not clear that this serves as more than an input-output channel for the externalization of language proper. Strikingly, the capability for auditory-vocal learning is not shared with our closest relatives, the apes, but is present in such remotely related groups as songbirds and marine mammals. There is increasing evidence for behavioural, neural and genetic similarities between speech acquisition and birdsong learning. At the same time, researchers have applied formal linguistic analysis to the vocalizations of both primates and songbirds. What have all these studies taught us about the evolution of language? Is the comparative study of an apparently species-specific trait like language feasible? We argue that comparative analysis remains an important method for the evolutionary reconstruction and causal analysis of the mechanisms underlying language. On the one hand, common descent has been important in the evolution of the brain, such that avian and mammalian brains may be largely homologous, particularly in the case of brain regions involved in auditory perception, vocalization and auditory memory. On the other hand, there has been convergent evolution of the capacity for auditory-vocal learning, and possibly for structuring of external vocalizations, such that apes lack the abilities that are shared between songbirds and humans. However, significant limitations to this comparative analysis remain. While all birdsong may be classified in terms of a particularly simple kind of concatenation system, the regular languages, there is no compelling evidence to date that birdsong matches the characteristic syntactic complexity of human language, arising from the composition of smaller forms like words and phrases into larger ones.

  2. Through the creator's eyes

    DEFF Research Database (Denmark)

    Glaveanu, Vlad Petre; Lahlou, Saadi

    2012-01-01

    of an adapted Subjective Evidence-Based Ethnography (SEBE). This methodology combines (a) obtaining first person audio-visual recordings of creative action with a miniature video-camera worn at eye-level, (b) accessing the subjective experience of the participant through a confrontation interview based...

  3. The Aging Eye

    Science.gov (United States)

    ... and Tips Watch, Listen, and Learn Social Media ¡Ojo con su visión! ¡Ojo con su visión! Learn About Eye Disease Among Hispanics/Latinos ¡Ojo con su visión! Toolkits Resources Outreach Tools and ...

  4. An eye for inspiration

    Science.gov (United States)

    2009-11-01

    The discovery that the eye of a particular mantis shrimp has an achromatic quarter-waveplate that is superior to modern-day devices could be a source of inspiration to those designing optical components. Nature Photonics spoke to Nicholas Roberts, one of the researchers involved in the study.

  5. About the Eye

    Medline Plus

    Full Text Available ... of Health (NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information ... and what it does. Macula (MACK-yoo-luh) is the small, sensitive area of the retina needed ...

  6. King and Eye

    DEFF Research Database (Denmark)

    Suwannakij, Sing

    devices, most significantly the photographic and the cine cameras, but also encompassing other ocular apparatuses. The images produced through the contraptions were brought together under the royal eye at the apex, which in turn claimed its supremacy over space, time, and the vast and diverse population...

  7. [Eye and the pregnacy].

    Science.gov (United States)

    Dima, Anne Marie

    2012-01-01

    Pregnancy is associated with changes in many organs and systems including the eyes. Sometimes in pregnancy may appear physiological and pathological ocular changes that may be associated with pre-existing problems. In such cases it is very important interdisciplinary collaboration gynecologist, ophthalmologist.

  8. Eyes for Learning

    Science.gov (United States)

    Orfield, Antonia

    2008-01-01

    Vision is the dominant sense, and the eyes are connected with almost every other part of the brain. If the vision system is poorly developed, children trying to learn suffer. Without good up close vision, students are handicapped even if no one knows or suspects it--they may not even know it themselves. Students do not know that the way they see…

  9. About the Eye

    Medline Plus

    Full Text Available ... NIH), the National Eye Institute’s mission is to “conduct and support research, training, health information dissemination, and ... carry visual messages from the retina to the brain. Retina (REH-tin-uh) is the light-sensitive ...

  10. About the Eye

    Medline Plus

    Full Text Available ... of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. Miller, Ph.D., ... David M. Schneeweis, Ph.D., Deputy Scientific Director Office of the Clinical Director Brian P. Brooks, M. ...

  11. Chromatic aberration correction of the human eye for retinal imaging in the near infrared.

    Science.gov (United States)

    Fernández, Enrique J; Unterhuber, Angelika; Povazay, Boris; Hermann, Boris; Artal, Pablo; Drexler, Woflgang

    2006-06-26

    An achromatizing lens has been designed for the human eye in the near infrared range, from 700 to 900 nm, for retinal imaging purposes. Analysis of the performance of the lens, including tolerance to misalignments, has been mathematically accomplished by using an existing eye model. The calculations have shown a virtually perfect correction of the ocular longitudinal chromatic aberration, while still keeping a high optical quality. Ocular aberrations in five subjects have been measured with and without the achromatizing lens by using a Hartmann-Shack wavefront sensor and a broad bandwidth femtosecond Ti:sapphire laser in the spectral range of interest with a set of interference filters, studying the benefits and limits in the use of the achromatizing lens. Ocular longitudinal chromatic aberration has been experimentally demonstrated to be fully corrected by the proposed lens, with no induction of any other parasitic aberration. The practical implementation of the achromatizing lens for Ophthalmoscopy, specifically for optical coherence tomography where the use of polychromatic light sources in the near infrared portion of the spectrum is mandatory, has been considered. The potential benefits of using this lens in combination with adaptive optics to achieve a full aberration correction of the human eye for retinal imaging have also been discussed.

  12. Learning robotic eye-arm-hand coordination from human demonstration: a coupled dynamical systems approach.

    Science.gov (United States)

    Lukic, Luka; Santos-Victor, José; Billard, Aude

    2014-04-01

    We investigate the role of obstacle avoidance in visually guided reaching and grasping movements. We report on a human study in which subjects performed prehensile motion with obstacle avoidance where the position of the obstacle was systematically varied across trials. These experiments suggest that reaching with obstacle avoidance is organized in a sequential manner, where the obstacle acts as an intermediary target. Furthermore, we demonstrate that the notion of workspace travelled by the hand is embedded explicitly in a forward planning scheme, which is actively involved in detecting obstacles on the way when performing reaching. We find that the gaze proactively coordinates the pattern of eye-arm motion during obstacle avoidance. This study provides also a quantitative assessment of the coupling between the eye-arm-hand motion. We show that the coupling follows regular phase dependencies and is unaltered during obstacle avoidance. These observations provide a basis for the design of a computational model. Our controller extends the coupled dynamical systems framework and provides fast and synchronous control of the eyes, the arm and the hand within a single and compact framework, mimicking similar control system found in humans. We validate our model for visuomotor control of a humanoid robot.

  13. Three-dimensional ray tracing for refractive correction of human eye ametropies

    Science.gov (United States)

    Jimenez-Hernandez, J. A.; Diaz-Gonzalez, G.; Trujillo-Romero, F.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.; Santiago-Alvarado, A.

    2016-09-01

    Ametropies of the human eye, are refractive defects hampering the correct imaging on the retina. The most common ways to correct them is by means of spectacles, contact lenses, and modern methods as laser surgery. However, in any case it is very important to identify the ametropia grade for designing the optimum correction action. In the case of laser surgery, it is necessary to define a new shape of the cornea in order to obtain the wanted refractive correction. Therefore, a computational tool to calculate the focal length of the optical system of the eye versus variations on its geometrical parameters is required. Additionally, a clear and understandable visualization of the evaluation process is desirable. In this work, a model of the human eye based on geometrical optics principles is presented. Simulations of light rays coming from a punctual source at six meter from the cornea are shown. We perform a ray-tracing in three dimensions in order to visualize the focusing regions and estimate the power of the optical system. The common parameters of ametropies can be easily modified and analyzed in the simulation by an intuitive graphic user interface.

  14. Machine vision based on the concept of contrast sensitivity of the human eye

    Science.gov (United States)

    Bezzubik, Vitali; Belashenkov, Nikolai; Vdovin, Gleb

    2014-09-01

    The model of contrast sensitivity function (CSF) of machine vision system, based on the CSF of the human visual system is proposed. By analogy with the human eye, we employ the concept of ganglion cell receptive field to the artificial light-sensitive elements. By further following this concept, we introduced quantative metrics of local and global contrast of digital image. We suggested that the contrast sensitivity threshold forms an iso-line in the parameter space contrast - spatial frequency. The model, implemented in a computer vision system, has been compared to the results of contrast sensitivity research, conducted directly with the human visual system, and demonstrated a good match.

  15. Novel automatic eye detection and tracking algorithm

    Science.gov (United States)

    Ghazali, Kamarul Hawari; Jadin, Mohd Shawal; Jie, Ma; Xiao, Rui

    2015-04-01

    The eye is not only one of the most complex but also the most important sensory organ of the human body. Eye detection and eye tracking are basement and hot issue in image processing. A non-invasive eye location and eye tracking is promising for hands-off gaze-based human-computer interface, fatigue detection, instrument control by paraplegic patients and so on. For this purpose, an innovation work frame is proposed to detect and tracking eye in video sequence in this paper. The contributions of this work can be divided into two parts. The first contribution is that eye filters were trained which can detect eye location efficiently and accurately without constraints on the background and skin colour. The second contribution is that a framework of tracker based on sparse representation and LK optic tracker were built which can track eye without constraint on eye status. The experimental results demonstrate the accuracy aspects and the real-time applicability of the proposed approach.

  16. Disability: recommendations for eye programmes

    Directory of Open Access Journals (Sweden)

    2013-05-01

    Full Text Available In 2012, CBM’s Medical Eye Care Advisory Working Group met in Hyderabad, India to discuss the inclusion of people with disabilities in eye care.As a result of these discussions, recommendations were made.

  17. Analysis of Schwalbe′s Line (Limbal Smooth Zone by Scanning Electron Microscopy and Optical Coherence Tomography in Human Eye Bank Eyes

    Directory of Open Access Journals (Sweden)

    Mark P Breazzano

    2013-01-01

    Full Text Available Purpose: Implantation of intraocular devices may become critical as they decrease in size in the future. Therefore, it is desirable to evaluate the relationship between radial location and Schwalbe′s line (smooth zone by examining its width with scanning electron microscopy (SEM and to correlate this with observations by optical coherence tomography (OCT. Methods: Full corneoscleral rings were obtained from twenty-six formalin-fixed human phakic donor eyes. SEM of each eye yielded a complete montage of the smooth zone, from which the area was measured, and width was determined in each quadrant. In three different eyes, time domain anterior segment OCT (Visante, Carl Zeiss Meditec Inc., Dublin, CA, USA and spectral domain OCT (Cirrus 4.0, Carl Zeiss Meditec Inc., Dublin, CA, USA were used to further characterize Schwalbe′s line. Results: The overall smooth zone width was 79±22 μm, (n=15 ranging from 43 to 115 μm. The superior quadrant (103±8 μm, n=19, demonstrated significantly wider smooth zone than both the nasal (71±5 μm, n=19, P0.05. SEM findings of the smooth zone were correlated with visualization of Schwalbe′s line by Cirrus and Visante OCT imaging. Conclusion: The smooth zone appears widest superiorly and thinnest inferonasally, suggesting that as glaucoma surgical devices become smaller, their placement could be targeted clinically by using OCT with preference to the superior quadrant, to minimize damage to the corneal endothelium.

  18. Unilateral Amblyopia Affects Two Eyes: Fellow Eye Deficits in Amblyopia.

    Science.gov (United States)

    Meier, Kimberly; Giaschi, Deborah

    2017-03-01

    Unilateral amblyopia is a visual disorder that arises after selective disruption of visual input to one eye during critical periods of development. In the clinic, amblyopia is understood as poor visual acuity in an eye that was deprived of pattern vision early in life. By its nature, however, amblyopia has an adverse effect on the development of a binocular visual system and the interactions between signals from two eyes. Visual functions aside from visual acuity are impacted, and many studies have indicated compromised sensitivity in the fellow eye even though it demonstrates normal visual acuity. While these fellow eye deficits have been noted, no overarching theory has been proposed to describe why and under what conditions the fellow eye is impacted by amblyopia. Here, we consider four explanations that may account for decreased fellow eye sensitivity: the fellow eye is adversely impacted by treatment for amblyopia; the maturation of the fellow eye is delayed by amblyopia; fellow eye sensitivity is impacted for visual functions that rely on binocular cortex; and fellow eye deficits reflect an adaptive mechanism that works to equalize the sensitivity of the two eyes. To evaluate these ideas, we describe five visual functions that are commonly reported to be deficient in the amblyopic eye (hyperacuity, contrast sensitivity, spatial integration, global motion, and motion-defined form), and unify the current evidence for fellow eye deficits. Further research targeted at exploring fellow eye deficits in amblyopia will provide us with a broader understanding of normal visual development and how amblyopia impacts the developing visual system.

  19. Pink Eye: What To Do

    Centers for Disease Control (CDC) Podcasts

    2010-10-12

    In this podcast, CDC's Adam Cohen, MD, a pediatrician and parent, discusses conjunctivitis (pink eye), a common eye condition in children and adults. He reviews pink eye causes and treatment, suggestions on when to call or visit a doctor, and practical tips to prevent pink eye from spreading.  Created: 10/12/2010 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 10/13/2010.

  20. Postural And Eye-Positional Effects On Human Biting Force: An Experimental Study

    Directory of Open Access Journals (Sweden)

    Altay Tabancacı

    2012-06-01

    Full Text Available Muscle groups affected on biting force are called temporal muscle as a major and masseter muscle as a minor. According to the human posture stability, forces of these muscles vary with the force directions. In this case, experimental investigation is strictly important such that biting force under different postural and eye- positional situations is changed. In this study, seven-male and seven-female within the age-range of 17-24 are considered corresponding to having with restorated molar tooth and without that type of tooth. With the help of specially designed biting fork, different posture- and eye-positions are investigated for experimental biting force analysis. Changes in eye-positions are not indicated significant difference for all postural positions. On one hand, it is obtained that biting force of no-filling tooth in men becomes maximum if facial muscles give full effort to biting. On the other hand, effect of facial muscles for women is not clearly noticed depending on the postural differences.

  1. Model propagation of a femtosecond laser radiation in the vitreous of the human eye

    Science.gov (United States)

    Rogov, P. Y.; Bespalov, V. G.

    2016-04-01

    The paper presents a mathematical model of linear and nonlinear processes occurring due to propagation of femtosecond laser pulses in vitreous of the human eye. By methods of numerical simulation, we have solved a nonlinear spectral equation describing dynamics of two-dimensional TE-polarized radiation. The solution was performed in a homogeneous isotropic medium with instantaneous cubic nonlinearity without using slowly varying envelope approximation. For simulation we used medium with parameters close to the optical media of the eye. The model of femtosecond radiation takes into account the dynamics of the process of dispersion pulse broadening in time and occurrence of self-focusing of the retina when passing through vitreous body of the eye. The dependence between pulse duration on the retina and duration of the input pulse was found, as well as the values of power density at which self-focusing occurs. It was shown that the main mechanism of radiation damage caused while using Ti-sapphire laser is photoionization. The results coincide with the results obtained by other scientists. They can be used to create Russian laser safety standards for femtosecond laser systems.

  2. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...

  3. Quick-Eye: Examination of Human Performance Characteristics Using Eye Tracking and Manual-Based Control Systems for Monitoring Multiple Displays

    Science.gov (United States)

    2013-03-01

    integration effort to combine eye - tracking technology into a multiple display information system, validation of the resulting system, and results of...studies conducted to determine the performance impact to response time, accuracy, and user workload by using eye - tracking input instead of manual controls to switch control among multiple displays.

  4. Tips for Buying Sports Eye Protectors

    Science.gov (United States)

    ... Financial Assistance Information Vision Screening and Eye Exams Zika Virus and Vision Eye Problems Eye Problems Amblyopia ( ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision ...

  5. Checklist for Your Eye Doctor Appointment

    Science.gov (United States)

    ... Financial Assistance Information Vision Screening and Eye Exams Zika Virus and Vision Eye Problems Eye Problems Amblyopia ( ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision ...

  6. Eye Symptom Questionnaire to Evaluate Anterior Eye Health.

    Science.gov (United States)

    Woodward, Maria A; Valikodath, Nita G; Newman-Casey, Paula Anne; Niziol, Leslie M; Musch, David C; Lee, Paul P

    2017-06-14

    Ophthalmologists assess eye complaints with a careful history and eye examination; however, other types of physicians have limited tools to evaluate anterior segment (AS) eye diseases. We identified the eye symptom questions that providers should ask to help determine the presence and urgency of AS eye diseases. Persons with and without AS disease completed a self-report eye symptom questionnaire (ESQ) based on the National Institutes of Health Toolbox symptom items in an academic center's corneal and comprehensive eye clinics. Gold standard ophthalmic examination determined the presence and urgency of AS disease. The association between reported symptom severity and the probability of AS disease, or urgent AS disease, was evaluated using logistic regression models, and sensitivity and specificity of the ESQ were also calculated. A total of 324 eyes of 162 subjects were included in the study. Of these, AS disease was present in 255 eyes (79%); of which, 111 eyes showed urgent disease. Increasing symptom severity for eye pain (odds ratio [OR]=2.58; P<0.001), glare (OR=2.61; P=0.001), and blurry vision (OR=1.98; P<0.001) were associated with increased odds of AS disease. Increasing symptom severity for eye pain (OR=2.02; P<0.001), eye redness (OR=1.69; P=0.02), and blurry vision (OR=1.41, P=0.01) were associated with increased odds of urgent AS disease. For the primary analysis with mild symptoms considered relevant, the sensitivity of the ESQ to detect AS disease was 83% and to detect urgent AS disease was 92%. Symptoms of eye pain, glare, redness, and blurry vision indicate the presence and urgency of AS disease.

  7. Questions Students Ask: The Red-Eye Effect.

    Science.gov (United States)

    Physics Teacher, 1985

    1985-01-01

    Addresses the question of why a dog's eyes appear red and glow when a flash photograph is taken. Conditions for the red-eye effect, light paths involved, structure of the eye, and typical cameras and lenses are discussed. Also notes differences between the eyes of nocturnal animals and humans. (JN)

  8. "Eye Science" in 2011

    Institute of Scientific and Technical Information of China (English)

    Jian Ge

    2011-01-01

    @@ 2011 is an opportune time for Yanke Xuebao (Eye Science) to launch its bilingual edition as a platform for cooperation between Chinese and international vision researchers.The yearly research output of Chinese investigators in all fields of science, but particularly biomedicine, has been growing recently by leaps and bounds.As an example, the American Journal of Ophthalmology (AJO), one of the most prestigious clinical journals in our field,received more submissions from East Asian authors (Japan, China and Korea alone)than they did from the United States in 2010.Chinese investigators ranked third on the list, climbing rapidly, only after the US and Japan.Top vision research centers in China, such as Zhongshan Ophthalmic Center, where Eye Science is published, now rank alongside Moorfields and Johns Hopkins as among the most prolific institutions in the world, measured by articles appearing annually in peer-reviewed SCI journals.

  9. Dry Eye Syndrome

    Directory of Open Access Journals (Sweden)

    Mohammad-Ali Javadi

    2011-01-01

    Full Text Available Our understanding of keratoconjunctivitis sicca (KCS, also known as dry eye syndrome, has been changed over recent years. Until lately, the condition was thought to be merely due to aqueous tear insufficiency. Today, it is understood that KCS is a multifactorial disorder due to inflammation of the ocular surface and lacrimal gland, neurotrophic deficiency and meibomian gland dysfunction. This change in paradigm has led to the development of new and more effective medications.

  10. Comprehensive eye evaluation algorithm

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Zamora, G.; Vahtel, M.; Soliz, P.; Barriga, S.

    2016-03-01

    In recent years, several research groups have developed automatic algorithms to detect diabetic retinopathy (DR) in individuals with diabetes (DM), using digital retinal images. Studies have indicated that diabetics have 1.5 times the annual risk of developing primary open angle glaucoma (POAG) as do people without DM. Moreover, DM patients have 1.8 times the risk for age-related macular degeneration (AMD). Although numerous investigators are developing automatic DR detection algorithms, there have been few successful efforts to create an automatic algorithm that can detect other ocular diseases, such as POAG and AMD. Consequently, our aim in the current study was to develop a comprehensive eye evaluation algorithm that not only detects DR in retinal images, but also automatically identifies glaucoma suspects and AMD by integrating other personal medical information with the retinal features. The proposed system is fully automatic and provides the likelihood of each of the three eye disease. The system was evaluated in two datasets of 104 and 88 diabetic cases. For each eye, we used two non-mydriatic digital color fundus photographs (macula and optic disc centered) and, when available, information about age, duration of diabetes, cataracts, hypertension, gender, and laboratory data. Our results show that the combination of multimodal features can increase the AUC by up to 5%, 7%, and 8% in the detection of AMD, DR, and glaucoma respectively. Marked improvement was achieved when laboratory results were combined with retinal image features.

  11. Lagophthalmos in enophthalmic eyes.

    Science.gov (United States)

    Yip, C-C; Gonzalez-Candial, M; Jain, A; Goldberg, R A; McCann, J D

    2005-06-01

    To report a case series of enophthalmic patients with lagophthalmos. A retrospective review of the electronic medical records at a tertiary health care centre of all patients with the diagnoses of "enophthalmos" and "lagophthalmos". Patients who had a history of diseases (such as Graves' orbitopathy), trauma or surgery of the orbit and eyelid were excluded. Enophthalmos was defined as exophthalmometric reading of 14 mm or less in both eyes. Seven patients (14 eyes) with bilateral enophthalmos were found to have concomitant lagophthalmos. All patients had deep superior sulci bilaterally. The upper eyelids were seen to be severely retro-placed behind the superior orbital rim. The extraocular motilities were full with no focal neurological deficit. The orbicularis oculi function was normal with no facial paralysis. The orbits were soft on retropulsion and no facial asymmetry was noted. The mean exophthalmolmetry reading measured 12.6 (SD 1.1) mm. The lagophthalmos varied from 1-5 mm. One patient (one eye) with 3 mm lagophthalmos developed a corneal ulcer and was treated with topical antibiotics and gold weight placement in the upper eyelid. Enophthalmic patients with deep superior sulci and retro-placed upper eyelids may present with lagophthalmos and exposure keratopathy.

  12. Speed and Vibration Performance as well as Obstacle Avoidance Performance of Electric Wheel Chair Controlled by Human Eyes Only

    Directory of Open Access Journals (Sweden)

    Kohei Arai

    2014-01-01

    Full Text Available Speed and vibration performance as well as obstacle avoidance performance of the previously proposed Electric Wheel Chair: EWC controlled by human eyes only is conducted. Experimental results show acceptable performances of speed vibration performance as well as obstacle avoidance performance for disabled persons. More importantly, disabled persons are satisfied with the proposed EWC because it works by their eyes only. Without hands and finger, they can control EWC freely.

  13. Expression of transforming growth factor-β2in vitreous body and adjacent tissues during prenatal development of human eye.

    Science.gov (United States)

    Sukhikh, G T; Panova, I G; Smirnova, Yu A; Milyushina, L A; Firsova, N V; Markitantova, Yu V; Poltavtseva, R A; Zinov'eva, R D

    2010-12-01

    Expression of transforming growth factor-β2 was detected by PCR in the vitreous body, lens, retina, and ciliary-iris complex of human eye at early stages of fetal development. Immunochemical assay of the corresponding protein in eye tissues revealed a correlation between the localization of transforming growth factor-β2 and the development of intraocular hyaloid vascular network, its regression, formation of the vitreous body, and development of definite retinal vessels.

  14. Spatiotemporal Filter for Visual Motion Integration from Pursuit Eye Movements in Humans and Monkeys.

    Science.gov (United States)

    Mukherjee, Trishna; Liu, Bing; Simoncini, Claudio; Osborne, Leslie C

    2017-02-08

    Despite the enduring interest in motion integration, a direct measure of the space-time filter that the brain imposes on a visual scene has been elusive. This is perhaps because of the challenge of estimating a 3D function from perceptual reports in psychophysical tasks. We take a different approach. We exploit the close connection between visual motion estimates and smooth pursuit eye movements to measure stimulus-response correlations across space and time, computing the linear space-time filter for global motion direction in humans and monkeys. Although derived from eye movements, we find that the filter predicts perceptual motion estimates quite well. To distinguish visual from motor contributions to the temporal duration of the pursuit motion filter, we recorded single-unit responses in the monkey middle temporal cortical area (MT). We find that pursuit response delays are consistent with the distribution of cortical neuron latencies and that temporal motion integration for pursuit is consistent with a short integration MT subpopulation. Remarkably, the visual system appears to preferentially weight motion signals across a narrow range of foveal eccentricities rather than uniformly over the whole visual field, with a transiently enhanced contribution from locations along the direction of motion. We find that the visual system is most sensitive to motion falling at approximately one-third the radius of the stimulus aperture. Hypothesizing that the visual drive for pursuit is related to the filtered motion energy in a motion stimulus, we compare measured and predicted eye acceleration across several other target forms.SIGNIFICANCE STATEMENT A compact model of the spatial and temporal processing underlying global motion perception has been elusive. We used visually driven smooth eye movements to find the 3D space-time function that best predicts both eye movements and perception of translating dot patterns. We found that the visual system does not appear to use

  15. Altered aquaporin expression in glaucoma eyes.

    Science.gov (United States)

    Tran, Thuy Linh; Bek, Toke; la Cour, Morten; Nielsen, Søren; Prause, Jan Ulrik; Hamann, Steffen; Heegaard, Steffen

    2014-09-01

    Aquaporins (AQP) are channels in the cell membrane that mainly facilitate a passive transport of water. In the eye, AQPs are expressed in the ciliary body and retina and may contribute to the pathogenesis of glaucoma and optic neuropathy. We investigated the expression of AQP1, AQP3, AQP4, AQP5, AQP7 and AQP9 in human glaucoma eyes compared with normal eyes. Nine glaucoma eyes were examined. Of these, three eyes were diagnosed with primary open angle glaucoma; three eyes had neovascular glaucoma; and three eyes had chronic angle-closure glaucoma. Six eyes with normal intraocular pressure and without glaucoma were used as control. Immunohistochemistry was performed using antibodies against AQP1, AQP3, AQP4, AQP5, AQP7 and AQP9. For each specimen, optical densities of immunoprecipitates were measured using Photoshop and the staining intensities were calculated. Immunostaining showed labelling of AQP7 and AQP9 in the nonpigmented ciliary epithelium and the staining intensities were significantly decreased in glaucoma eyes (p = 0.003; p = 0.018). AQP7 expression in the Müller cell endfeet was increased (p = 0.046), and AQP9 labelling of the retinal ganglion cells (RGC) showed decreased intensity (p = 0.037). No difference in AQP1, AQP4 and AQP9 expression was found in the optic nerve fibres. This study is the first investigating AQPs in human glaucoma eyes. We found a reduced expression of AQP9 in the retinal ganglion cells of glaucoma eyes. Glaucoma also induced increased AQP7 expression in the Müller cell endfeet. In the ciliary body of glaucoma eyes, the expression of AQP7 and AQP9 was reduced. Therefore, the expression of AQPs seems to play a role in glaucoma.

  16. Eye surgery in the elderly

    Directory of Open Access Journals (Sweden)

    Raczyńska D

    2016-04-01

    Full Text Available Dorota Raczyńska, Leopold Glasner, Ewelina Serkies-Minuth, Magdalena A Wujtewicz, Kamila Mitrosz Department of Ophthalmology, Medical University of Gdansk, Gdansk, Poland Abstract: Extending life expectancy is a human achievement. It does however entail problems. Ophthalmic treatments are widely recognized as having a low risk of general complications. A classic example is cataract surgery, considered to be one of the safest and most frequently performed surgical procedures in the world. However, advanced age brings with it risks that should be considered before surgery. Eye operations, as with procedures on other organs, are largely dependent on the quality of surgical tissues. Therefore, the elderly are at increased risk of complications. Improved general health and postoperative follow-up with the use of noninvasive technologies such as optical coherence tomography translate into lower intraoperative risk and better postoperative prognosis. In this review, we discuss the impact of general health on operational prognosis, therapeutic problems, and technical difficulties which a surgeon and anesthesiologist may encounter in the process. We also consider new technology and strategies specifically aimed at treating eye conditions in the elderly. Keywords: eye surgery, eye aging, anesthesiology in ophthalmology, cataract, glaucoma, vitrectomy, age-related macular degeneration

  17. 'An eye, for eyes - mission' - From dream to reality

    Directory of Open Access Journals (Sweden)

    Parikumar P

    2013-10-01

    Full Text Available Corneal transplantation has been in routine practice to treat corneal endothelial diseases like Bullous Keratopathy, in which either the whole cornea or the partial cornea (the endothelium alone is transplanted from the cadaver donor to the recipient with the endothelial disease [1]. In whole corneal or partial corneal transplant one cadaver donor's cornea can be used to treat one recipient cornea only, which leads to a huge global shortage of donor corneas [2]. At this juncture Yokoo et al isolated and expanded corneal endothelial precursors using the sphere forming assay in vitro [3] and demonstrated the in vivo transplantation of these corneal endothelial precursors in a rabbit model of bullous keratopathy [4]. Following this, we studied the transportation of cadaver donor derived corneal endothelial tissue (CET from human cadaver donors in a thermoreversible gelation polymer (TGP (4 based transportation cocktail without cool preservation and demonstrated the viability of human corneal endothelial precursor (HCEP cells isolated from these CETs even after 72 hours of transportation without cool preservation [5]. This was done to suit the conditions existing in developing nations like India where hospitals might be located far from eye banks and maintaining cold chain preservation is relatively difficult. Further, these HCEPs were expanded in vitro using a polymer based expansion protocol [5]. This was the first step in the realisation of the dream of 'Eye for eyes' in a manner suitable for Indian conditions. Corneal transplantation has been in routine practice to treat corneal endothelial diseases like Bullous Keratopathy, in which either the whole cornea or the partial cornea (the endothelium alone is transplanted from the cadaver donor to the recipient with the endothelial disease [1]. In whole corneal or partial corneal transplant one cadaver donor's cornea can be used to treat one recipient cornea only, which leads to a huge global

  18. Reconstituted human corneal epithelium: a new alternative to the Draize eye test for the assessment of the eye irritation potential of chemicals and cosmetic products.

    Science.gov (United States)

    Doucet, O; Lanvin, M; Thillou, C; Linossier, C; Pupat, C; Merlin, B; Zastrow, L

    2006-06-01

    The aim of this study was to evaluate the interest of a new three-dimensional epithelial model cultivated from human corneal cells to replace animal testing in the assessment of eye tolerance. To this end, 65 formulated cosmetic products and 36 chemicals were tested by means of this in vitro model using a simplified toxicokinetic approach. The chemicals were selected from the ECETOC data bank and the EC/HO International validation study list. Very satisfactory results were obtained in terms of concordance with the Draize test data for the formulated cosmetic products. Moreover, the response of the corneal model appeared predictive of human ocular response clinically observed by ophthalmologists. The in vitro scores for the chemicals tested strongly correlated with their respective scores in vivo. For all the compounds tested, the response of the corneal model to irritants was similar regardless of their chemical structure, suggesting a good robustness of the prediction model proposed. We concluded that this new three-dimensional epithelial model, developed from human corneal cells, could be promising for the prediction of eye irritation induced by chemicals and complex formulated products, and that these two types of materials should be tested using a similar protocol. A simple shortening of the exposure period was required for the chemicals assumed to be more aggressively irritant to the epithelial tissues than the cosmetic formulae.

  19. Eye Movements in Reading as Rational Behavior

    Science.gov (United States)

    Bicknell, Klinton

    2011-01-01

    Moving one's eyes while reading is one of the most complex everyday tasks humans face. To perform efficiently, readers must make decisions about when and where to move their eyes every 200-300ms. Over the past decades, it has been demonstrated that these fine-grained decisions are influenced by a range of linguistic properties of the text, and…

  20. Altered aquaporin expression in glaucoma eyes

    DEFF Research Database (Denmark)

    Tran, Thuy Linh; Bek, Toke; la Cour, Morten

    2014-01-01

    Aquaporins (AQP) are channels in the cell membrane that mainly facilitate a passive transport of water. In the eye, AQPs are expressed in the ciliary body and retina and may contribute to the pathogenesis of glaucoma and optic neuropathy. We investigated the expression of AQP1, AQP3, AQP4, AQP5......, AQP7 and AQP9 in human glaucoma eyes compared with normal eyes. Nine glaucoma eyes were examined. Of these, three eyes were diagnosed with primary open angle glaucoma; three eyes had neovascular glaucoma; and three eyes had chronic angle-closure glaucoma. Six eyes with normal intraocular pressure...... of AQP7 and AQP9 in the nonpigmented ciliary epithelium and the staining intensities were significantly decreased in glaucoma eyes (p = 0.003; p = 0.018). AQP7 expression in the Müller cell endfeet was increased (p = 0.046), and AQP9 labelling of the retinal ganglion cells (RGC) showed decreased...

  1. Dependences between kinetics of the human eye pupil and blood pulsation

    Science.gov (United States)

    Szmigiel, Marta A.; Kasprzak, Henryk; Klysik, Anna

    2016-09-01

    The study presents measurement and numerical analysis of time variability of the eye pupil geometry and its position, as well as their correlations with blood pulsation. The image of the eye pupil was recorded by use of the fast CCD camera with 200 fps rates. Blood pulsation was synchronously recorded by use of pulse transducer with the sampling frequency of 200 Hz. Each single image from a sequence was numerically processed. Contour of the eye pupil was approximated, and its selected geometrical parameters as well as center positions were calculated. Spectral and coherence analysis of time variability of calculated pupil parameters and blood pulsation were determined.

  2. Application of Fourier Domain OCT Imaging Technology to the Anterior Segment of the Human Eye

    Science.gov (United States)

    Wojtkowski, Maciej; Marcos, Susana; Ortiz, Sergio; Grulkowski, Ireneusz

    The anterior segment is the front part of the human eye, which forms the optical system and hence directly impacts vision. Traumatic or pathological changes in the anterior segment may lead to vision loss and, in some cases, even blindness. Since the eighteenth century, optical instrumentation for measuring and imaging the anterior segment of the human eye has been developing along with modern ophthalmology. The application of OCT to the anterior segment imaging is particularly of interest, since this could potentially provide substantial complementary information regarding the large-scale architecture of the cornea and the crystalline lens, or on small portions of tissue imaged with high spatial resolutions comparable to regular microscopy. Especially an introduction of Fourier domain detection in OCT has opened new frontiers in OCT ophthalmic applications. The resultant substantial speed improvement enables rapid image acquisition, helping to reduce artifacts due to patient motion. Thus, it is currently possible to perform high-speed, in vivo, three-dimensional volumetric imaging over large scales within a reasonable time limit and without reducing system sensitivity. This chapter describes the state-of the art OCT technology dedicated to anterior segment imaging and indicates all important parameters which are required for optimization of the performance of OCT instrument.

  3. Objective straylight assessment of the human eye with a novel device

    Science.gov (United States)

    Schramm, Stefan; Schikowski, Patrick; Lerm, Elena; Kaeding, André; Klemm, Matthias; Haueisen, Jens; Baumgarten, Daniel

    2016-03-01

    Forward scattered light from the anterior segment of the human eye can be measured by Shack-Hartmann (SH) wavefront aberrometers with limited visual angle. We propose a novel Point Spread Function (PSF) reconstruction algorithm based on SH measurements with a novel measurement devise to overcome these limitations. In our optical setup, we use a Digital Mirror Device as variable field stop, which is conventionally a pinhole suppressing scatter and reflections. Images with 21 different stop diameters were captured and from each image the average subaperture image intensity and the average intensity of the pupil were computed. The 21 intensities represent integral values of the PSF which is consequently reconstructed by derivation with respect to the visual angle. A generalized form of the Stiles-Holladay-approximation is fitted to the PSF resulting in a stray light parameter Log(IS). Additionaly the transmission loss of eye is computed. For the proof of principle, a study on 13 healthy young volunteers was carried out. Scatter filters were positioned in front of the volunteer's eye during C-Quant and scatter measurements to generate straylight emulating scatter in the lens. The straylight parameter is compared to the C-Quant measurement parameter Log(ISC) and scatter density of the filters SDF with a partial correlation. Log(IS) shows significant correlation with the SDF and Log(ISC). The correlation is more prominent between Log(IS) combined with the transmission loss and the SDF and Log(ISC). Our novel measurement and reconstruction technique allow for objective stray light analysis of visual angles up to 4 degrees.

  4. Measuring higher order optical aberrations of the human eye: techniques and applications

    Directory of Open Access Journals (Sweden)

    L. Alberto V. Carvalho

    2002-11-01

    Full Text Available In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia and higher order aberrations (coma, spherical aberration, etc.. We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.

  5. Through Einstein's Eyes

    CERN Document Server

    Searle, A C; Altin, P A; Bennet, F H; Hush, M R; Searle, Antony C.; Savage, Craig M.; Altin, Paul A.; Bennet, Francis H.; Hush, Michael R.

    2005-01-01

    We have developed a relativistically-accurate computer graphics code and have used it to produce photo-realistic images and videos of scenes where special relativistic effects dominate, either in astrophysical contexts or in imaginary worlds where the speed of light is only a few metres per second. The videos have been integrated into our under-graduate teaching programme for several years. Recently we took the next step, encouraging undergraduate students to use the code to explore relativity, develop their own videos, and eventually package them together into Through Einstein's Eyes, a multimedia CD.

  6. Eye trauma in boxing.

    Science.gov (United States)

    Corrales, Gustavo; Curreri, Anthony

    2009-10-01

    In boxing, along with a few other sports, trauma is inherent to the nature of the sport; therefore it is considered a high-risk sport for ocular injuries. The long-term morbidity of ocular injuries suffered by boxers is difficult to estimate due to the lack of structured long-term follow-up of these athletes. Complications of blunt ocular trauma may develop years after the athlete has retired from the ring and is no longer considered to be at risk for boxing-related injuries. This article describes the wide range of eye injuries a boxer can sustain, and their immediate and long-term clinical management.

  7. Towards free 3D end-point control for robotic-assisted human reaching using binocular eye tracking.

    Science.gov (United States)

    Maimon-Dror, Roni O; Fernandez-Quesada, Jorge; Zito, Giuseppe A; Konnaris, Charalambos; Dziemian, Sabine; Faisal, A Aldo

    2017-07-01

    Eye-movements are the only directly observable behavioural signals that are highly correlated with actions at the task level, and proactive of body movements and thus reflect action intentions. Moreover, eye movements are preserved in many movement disorders leading to paralysis (or amputees) from stroke, spinal cord injury, Parkinson's disease, multiple sclerosis, and muscular dystrophy among others. Despite this benefit, eye tracking is not widely used as control interface for robotic interfaces in movement impaired patients due to poor human-robot interfaces. We demonstrate here how combining 3D gaze tracking using our GT3D binocular eye tracker with custom designed 3D head tracking system and calibration method enables continuous 3D end-point control of a robotic arm support system. The users can move their own hand to any location of the workspace by simple looking at the target and winking once. This purely eye tracking based system enables the end-user to retain free head movement and yet achieves high spatial end point accuracy in the order of 6 cm RMSE error in each dimension and standard deviation of 4 cm. 3D calibration is achieved by moving the robot along a 3 dimensional space filling Peano curve while the user is tracking it with their eyes. This results in a fully automated calibration procedure that yields several thousand calibration points versus standard approaches using a dozen points, resulting in beyond state-of-the-art 3D accuracy and precision.

  8. Human head orientation and eye visibility as indicators of attention for goats (Capra hircus).

    Science.gov (United States)

    Nawroth, Christian; McElligott, Alan G

    2017-01-01

    Animals domesticated for working closely with humans (e.g. dogs) have been shown to be remarkable in adjusting their behaviour to human attentional stance. However, there is little evidence for this form of information perception in species domesticated for production rather than companionship. We tested domestic ungulates (goats) for their ability to differentiate attentional states of humans. In the first experiment, we investigated the effect of body and head orientation of one human experimenter on approach behaviour by goats. Test subjects (N = 24) significantly changed their behaviour when the experimenter turned its back to the subjects, but did not take into account head orientation alone. In the second experiment, goats (N = 24) could choose to approach one of two experimenters, while only one was paying attention to them. Goats preferred to approach humans that oriented their body and head towards the subject, whereas head orientation alone had no effect on choice behaviour. In the third experiment, goats (N = 32) were transferred to a separate test arena and were rewarded for approaching two experimenters providing a food reward during training trials. In subsequent probe test trials, goats had to choose between the two experimenters differing in their attentional states. Like in Experiments 1 and 2, goats did not show a preference for the attentive person when the inattentive person turned her head away from the subject. In this last experiment, goats preferred to approach the attentive person compared to a person who closed their eyes or covered the whole face with a blind. However, goats showed no preference when one person covered only the eyes. Our results show that animals bred for production rather than companionship show differences in their approach and choice behaviour depending on human attentive state. However, our results contrast with previous findings regarding the use of the head orientation to attribute attention and show the importance

  9. EyePhy: Detecting Dependencies in Cyber-Physical System Apps due to Human-in-the-Loop

    Directory of Open Access Journals (Sweden)

    Sirajum Munir

    2015-07-01

    Full Text Available As app based paradigms are becoming popular, millions of apps are developed from many domains including energy, health, security, and entertainment. The US FDA expects that there will be 500 million smart phone users downloading healthcare related apps by 2015. Many of these apps are Cyber-Physical System (CPS apps. In addition to sensing, communication, and computation, they perform interventions to control human physiological parameters, which can cause dependency problems as multiple interventions of multiple apps can increase or decrease each others effects, some of which can be harmful to the user. Such dependency problems occur mainly because each app is unaware about how other apps work and when an app performs an intervention to control its target parameters, it may affect other physiological parameters without even knowing it. We present EyePhy, a system that detects dependencies across interventions by having a closer eye on the physiological parameters of the human in the loop. To do that, EyePhy uses a physiological simulator HumMod that can model the complex interactions of the human physiology using over 7800 variables. EyePhy reduces app developers’ efforts in specifying dependency metadata compared to state of the art solutions and offers personalized dependency analysis for the user. We demonstrate the magnitude of dependencies that arise during multiple interventions in a human body and the significant ability of detecting these dependencies using EyePhy.

  10. A Seeing-eye Dog

    Institute of Scientific and Technical Information of China (English)

    范图雨

    2000-01-01

    A seeing-eye dog is a special(特殊的) dog. It helps blind people walk along the streets and do many other things. We call these dogs ""seeing-eye"" dogs because the dogs are the ""eyes"" of the blind man and they help him to ""see"". These dogs go to special schools for several years to learn to help blind people.

  11. The Eyes as Windows Into Other Minds.

    Science.gov (United States)

    Grossmann, Tobias

    2017-01-01

    Eyes have been shown to play a key role during human social interactions. However, to date, no comprehensive cross-discipline model has provided a framework that can account for uniquely human responses to eye cues. In this review, I present a framework that brings together work on the phylogenetic, ontogenetic, and neural bases of perceiving and responding to eyes. Specifically, I argue for a two-process model: a first process that ensures privileged attention to information encoded in the eyes and is important for the detection of other minds and a second process that permits the decoding of information contained in the eyes concerning another person's emotional and mental states. To some degree, these processes are unique to humans, emerge during different times in infant development, can be mapped onto distinct but interconnected brain regions, and likely serve critical functions in facilitating cooperative interactions in humans. I also present evidence to show that oxytocin is a key modulator of sensitive responding to eye cues. Viewing eyes as windows into other minds can therefore be considered a hallmark feature of human social functioning deeply rooted in our biology.

  12. Bona fide colour: DNA prediction of human eye and hair colour from ancient and contemporary skeletal remains.

    Science.gov (United States)

    Draus-Barini, Jolanta; Walsh, Susan; Pośpiech, Ewelina; Kupiec, Tomasz; Głąb, Henryk; Branicki, Wojciech; Kayser, Manfred

    2013-01-14

    DNA analysis of ancient skeletal remains is invaluable in evolutionary biology for exploring the history of species, including humans. Contemporary human bones and teeth, however, are relevant in forensic DNA analyses that deal with the identification of perpetrators, missing persons, disaster victims or family relationships. They may also provide useful information towards unravelling controversies that surround famous historical individuals. Retrieving information about a deceased person's externally visible characteristics can be informative in both types of DNA analyses. Recently, we demonstrated that human eye and hair colour can be reliably predicted from DNA using the HIrisPlex system. Here we test the feasibility of the novel HIrisPlex system at establishing eye and hair colour of deceased individuals from skeletal remains of various post-mortem time ranges and storage conditions. Twenty-one teeth between 1 and approximately 800 years of age and 5 contemporary bones were subjected to DNA extraction using standard organic protocol followed by analysis using the HIrisPlex system. Twenty-three out of 26 bone DNA extracts yielded the full 24 SNP HIrisPlex profile, therefore successfully allowing model-based eye and hair colour prediction. HIrisPlex analysis of a tooth from the Polish general Władysław Sikorski (1881 to 1943) revealed blue eye colour and blond hair colour, which was positively verified from reliable documentation. The partial profiles collected in the remaining three cases (two contemporary samples and a 14th century sample) were sufficient for eye colour prediction. Overall, we demonstrate that the HIrisPlex system is suitable, sufficiently sensitive and robust to successfully predict eye and hair colour from ancient and contemporary skeletal remains. Our findings, therefore, highlight the HIrisPlex system as a promising tool in future routine forensic casework involving skeletal remains, including ancient DNA studies, for the prediction of

  13. Reading between eye saccades.

    Directory of Open Access Journals (Sweden)

    Caroline Blais

    Full Text Available BACKGROUND: Skilled adult readers, in contrast to beginners, show no or little increase in reading latencies as a function of the number of letters in words up to seven letters. The information extraction strategy underlying such efficiency in word identification is still largely unknown, and methods that allow tracking of the letter information extraction through time between eye saccades are needed to fully address this question. METHODOLOGY/PRINCIPAL FINDINGS: The present study examined the use of letter information during reading, by means of the Bubbles technique. Ten participants each read 5,000 five-letter French words sampled in space-time within a 200 ms window. On the temporal dimension, our results show that two moments are especially important during the information extraction process. On the spatial dimension, we found a bias for the upper half of words. We also show for the first time that letter positions four, one, and three are particularly important for the identification of five-letter words. CONCLUSIONS/SIGNIFICANCE: Our findings are consistent with either a partially parallel reading strategy or an optimal serial reading strategy. We show using computer simulations that this serial reading strategy predicts an absence of a word-length effect for words from four- to seven letters in length. We believe that the Bubbles technique will play an important role in further examining the nature of reading between eye saccades.

  14. Eye in pregnancy

    Directory of Open Access Journals (Sweden)

    Achyut N. Pandey

    2014-02-01

    Full Text Available Hormonal, metabolic, hemodynamic, vascular and immunological changes that occur during pregnancy can affect the function of the eye. These changes are commonly transient, but in some cases they may be permanent and have consequences even after childbirth. The ocular effects of pregnancy may be physiological or pathological and can be associated with the development of new ocular pathology or may be modifications of pre-existing conditions. The most common physiological changes are alterations of corneal sensitivity and thickness, decreased tolerance to contact lenses, decreased intraocular pressure, hemeralopia and refractive errors. Possible posterior segment changes include worsening of diabetic retinopathy, central serous chorioretinopathy, increased risk of peripheral vitreochorioretinal dystrophies and retinal detachment. Thus, it should be kept in mind that the presence of any ocular symptoms in a pregnant woman requires ophthalmologic examination and further management. Knowledge of these ocular changes can help to differentiate the physiological changes from ocular manifestation of systemic disease and diseases pertaining to the eye in a pregnant woman. This article explains the effects of ocular changes in pregnancy. [Int J Res Med Sci 2014; 2(1.000: 16-20

  15. Real Time Eye Template Detection and Tracking

    Directory of Open Access Journals (Sweden)

    Richa Mehta

    2012-06-01

    Full Text Available There has been a growing interest in the field of facial expression recognition especially in the last two decades. An example of such a system is the improvement of driver carefulness and accident reduction. The driver’s face is tracked while he is driving and he is warned if there seems to be an alerting fact that can result in an accident such as sleepy eyes, or looking out of the road. Furthermore, with a facial feature tracker, it becomes possible to play a synthesized avatar so that it imitates the expressions of the performer. Human-Computer Interaction (HCI systems may also be enriched by a facial feature tracker. For a user who is incapable of using her hands, a facial expression controller may be a solution to send limited commands to a computer. Eye blinking is one of the prominent areas to solve many real world problems. The process of blink detection consists of two phases. These are eye tracking followed by detection of blink. The work that has been carried out for eye tracking only is not suitable for eye blink detection. Therefore some approaches had been proposed for eye tracking along with eyes blink detection. In this thesis, real time implementation is done to count number of eye blinks in an image sequence. At last after analyzing all these approaches some of the parameters we obtained on which better performance of eye blink detection algorithm depend. This project focuses on automatic eye blink detection in real time. The aim of this thesis is to count the number of eye blinks in a video. This project will be performed on a video database of the facial expressions.

  16. Fetal eye movements on magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Ramona Woitek

    Full Text Available OBJECTIVES: Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. METHODS: Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]. Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981: Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. RESULTS: In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%. Significant differences between the age groups were found for Type I (p = 0.03, Type Ia (p = 0.031, and Type IV eye movements (p = 0.033. Consistently parallel bulbs were found in 27.3-45%. CONCLUSIONS: In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.

  17. Fetal eye movements on magnetic resonance imaging.

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3-45%. In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.

  18. Fetal Eye Movements on Magnetic Resonance Imaging

    Science.gov (United States)

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C.; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Objectives Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Methods Dynamic SSFP sequences were acquired in 72 singleton fetuses (17–40 GW, three age groups [17–23 GW, 24–32 GW, 33–40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. Results In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3–45%. Conclusions In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations. PMID:24194885

  19. FDTD Computation of Human Eye Exposure to Ultra-wideband Electromagnetic Pulses

    CERN Document Server

    Simicevic, Neven

    2007-01-01

    With an increase in the application of ultra-wideband (UWB) electromagnetic pulses in the communications industry, radar, biotechnology and medicine, comes an interest in UWB exposure safety standards. Despite an increase of the scientific research on bioeffects of exposure to non-ionizing UWB pulses, characterization of those effects is far from complete. A numerical computational approach, such as a finite-difference time domain (FDTD) method, is required to visualize and understand the complexity of broadband electromagnetic interactions. The FDTD method has almost no limits in the description of the geometrical and dispersive properties of the simulated material, it is numerically robust and appropriate for current computer technology. In this paper, a complete calculation of exposure of the human eye to UWB electromagnetic pulses in the frequency range of 3.1-10.6, 22-29, and 57-64 GHz is performed. Computation in this frequency range required a geometrical resolution of the eye of $\\rm 0.1 \\: mm$ and an...

  20. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

    Energy Technology Data Exchange (ETDEWEB)

    Mahdipour, Seyed Ali [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); Mowlavi, Ali Asghar, E-mail: amowlavi@hsu.ac.ir [Physics Department, Hakim Sabzevari University, Sabzevar (Iran, Islamic Republic of); ICTP, Associate Federation Scheme, Medical Physics Field, Trieste (Italy)

    2016-07-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  1. Use of Eye Tracking as an Innovative Instructional Method in Surgical Human Anatomy.

    Science.gov (United States)

    Sánchez-Ferrer, María Luísa; Grima-Murcia, María Dolores; Sánchez-Ferrer, Francisco; Hernández-Peñalver, Ana Isabel; Fernández-Jover, Eduardo; Sánchez Del Campo, Francisco

    Tobii glasses can record corneal infrared light reflection to track pupil position and to map gaze focusing in the video recording. Eye tracking has been proposed for use in training and coaching as a visually guided control interface. The aim of our study was to test the potential use of these glasses in various situations: explanations of anatomical structures on tablet-type electronic devices, explanations of anatomical models and dissected cadavers, and during the prosection thereof. An additional aim of the study was to test the use of the glasses during laparoscopies performed on Thiel-embalmed cadavers (that allows pneumoinsufflation and exact reproduction of the laparoscopic surgical technique). The device was also tried out in actual surgery (both laparoscopy and open surgery). We performed a pilot study using the Tobii glasses. Dissection room at our School of Medicine and in the operating room at our Hospital. To evaluate usefulness, a survey was designed for use among students, instructors, and practicing physicians. The results were satisfactory, with the usefulness of this tool supported by more than 80% positive responses to most questions. There was no inconvenience for surgeons and that patient safety was ensured in the real laparoscopy. To our knowledge, this is the first publication to demonstrate the usefulness of eye tracking in practical instruction of human anatomy, as well as in teaching clinical anatomy and surgical techniques in the dissection and operating rooms. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  2. Tissue Distribution of trans-Resveratrol and Its Metabolites after Oral Administration in Human Eyes

    Directory of Open Access Journals (Sweden)

    Shuaishuai Wang

    2017-01-01

    Full Text Available Purpose. This study was performed to measure the concentration of trans-resveratrol and its three metabolites in human eyes. Methods. The patients who underwent pars plana vitrectomy for rhegmatogenous retinal detachment were included. The participants were orally given trans-resveratrol-based supplement (Longevinex®. A suitable amount of conjunctiva, aqueous humor, and vitreous humor were obtained during the operation. High-performance liquid chromatography (HPLC with mass spectrometry (LC/MS/MS was used to detect the concentration of trans-resveratrol and its three metabolites in the various samples. Results. The average concentration of resveratrol in the conjunctiva was 17.19 ± 15.32 nmol/g (mean ± SD. The concentration of resveratrol in the aqueous humor was close to the limit of detection, but its metabolites could be quantified. The concentrations of resveratrol metabolites in the aqueous humor can be detected. In the vitreous humor, the average concentration of resveratrol-3-O-sulfate was 62.95 ± 41.97 nmol/L. The sulfate conjugations of resveratrol were recovered in the conjunctiva, aqueous humor, and vitreous humor. Conclusions. Resveratrol and its three metabolites can be detected in the ocular tissues after oral administration. Although the concentration of parent resveratrol was low in the eyes, its metabolites could be detected and may have a role in the treatment of ocular diseases.

  3. Simple, inexpensive technique for high-quality smartphone fundus photography in human and animal eyes.

    Science.gov (United States)

    Haddock, Luis J; Kim, David Y; Mukai, Shizuo

    2013-01-01

    Purpose. We describe in detail a relatively simple technique of fundus photography in human and rabbit eyes using a smartphone, an inexpensive app for the smartphone, and instruments that are readily available in an ophthalmic practice. Methods. Fundus images were captured with a smartphone and a 20D lens with or without a Koeppe lens. By using the coaxial light source of the phone, this system works as an indirect ophthalmoscope that creates a digital image of the fundus. The application whose software allows for independent control of focus, exposure, and light intensity during video filming was used. With this app, we recorded high-definition videos of the fundus and subsequently extracted high-quality, still images from the video clip. Results. The described technique of smartphone fundus photography was able to capture excellent high-quality fundus images in both children under anesthesia and in awake adults. Excellent images were acquired with the 20D lens alone in the clinic, and the addition of the Koeppe lens in the operating room resulted in the best quality images. Successful photodocumentation of rabbit fundus was achieved in control and experimental eyes. Conclusion. The currently described system was able to take consistently high-quality fundus photographs in patients and in animals using readily available instruments that are portable with simple power sources. It is relatively simple to master, is relatively inexpensive, and can take advantage of the expanding mobile-telephone networks for telemedicine.

  4. Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit.

    Science.gov (United States)

    Mahdipour, Seyed Ali; Mowlavi, Ali Asghar

    2016-01-01

    Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth-dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8MeV proton, 190.1MeV alpha, and 1060MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam׳s Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

  5. Fast ray-tracing of human eye optics on Graphics Processing Units.

    Science.gov (United States)

    Wei, Qi; Patkar, Saket; Pai, Dinesh K

    2014-05-01

    We present a new technique for simulating retinal image formation by tracing a large number of rays from objects in three dimensions as they pass through the optic apparatus of the eye to objects. Simulating human optics is useful for understanding basic questions of vision science and for studying vision defects and their corrections. Because of the complexity of computing such simulations accurately, most previous efforts used simplified analytical models of the normal eye. This makes them less effective in modeling vision disorders associated with abnormal shapes of the ocular structures which are hard to be precisely represented by analytical surfaces. We have developed a computer simulator that can simulate ocular structures of arbitrary shapes, for instance represented by polygon meshes. Topographic and geometric measurements of the cornea, lens, and retina from keratometer or medical imaging data can be integrated for individualized examination. We utilize parallel processing using modern Graphics Processing Units (GPUs) to efficiently compute retinal images by tracing millions of rays. A stable retinal image can be generated within minutes. We simulated depth-of-field, accommodation, chromatic aberrations, as well as astigmatism and correction. We also show application of the technique in patient specific vision correction by incorporating geometric models of the orbit reconstructed from clinical medical images. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Simple, Inexpensive Technique for High-Quality Smartphone Fundus Photography in Human and Animal Eyes

    Directory of Open Access Journals (Sweden)

    Luis J. Haddock

    2013-01-01

    Full Text Available Purpose. We describe in detail a relatively simple technique of fundus photography in human and rabbit eyes using a smartphone, an inexpensive app for the smartphone, and instruments that are readily available in an ophthalmic practice. Methods. Fundus images were captured with a smartphone and a 20D lens with or without a Koeppe lens. By using the coaxial light source of the phone, this system works as an indirect ophthalmoscope that creates a digital image of the fundus. The application whose software allows for independent control of focus, exposure, and light intensity during video filming was used. With this app, we recorded high-definition videos of the fundus and subsequently extracted high-quality, still images from the video clip. Results. The described technique of smartphone fundus photography was able to capture excellent high-quality fundus images in both children under anesthesia and in awake adults. Excellent images were acquired with the 20D lens alone in the clinic, and the addition of the Koeppe lens in the operating room resulted in the best quality images. Successful photodocumentation of rabbit fundus was achieved in control and experimental eyes. Conclusion. The currently described system was able to take consistently high-quality fundus photographs in patients and in animals using readily available instruments that are portable with simple power sources. It is relatively simple to master, is relatively inexpensive, and can take advantage of the expanding mobile-telephone networks for telemedicine.

  7. An exploratory study on the driving method of speech synthesis based on the human eye reading imaging data

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2016-10-01

    With the development of information technology and artificial intelligence, speech synthesis plays a significant role in the fields of Human-Computer Interaction Techniques. However, the main problem of current speech synthesis techniques is lacking of naturalness and expressiveness so that it is not yet close to the standard of natural language. Another problem is that the human-computer interaction based on the speech synthesis is too monotonous to realize mechanism of user subjective drive. This thesis introduces the historical development of speech synthesis and summarizes the general process of this technique. It is pointed out that prosody generation module is an important part in the process of speech synthesis. On the basis of further research, using eye activity rules when reading to control and drive prosody generation was introduced as a new human-computer interaction method to enrich the synthetic form. In this article, the present situation of speech synthesis technology is reviewed in detail. Based on the premise of eye gaze data extraction, using eye movement signal in real-time driving, a speech synthesis method which can express the real speech rhythm of the speaker is proposed. That is, when reader is watching corpora with its eyes in silent reading, capture the reading information such as the eye gaze duration per prosodic unit, and establish a hierarchical prosodic pattern of duration model to determine the duration parameters of synthesized speech. At last, after the analysis, the feasibility of the above method is verified.

  8. Multiscale systems integration in the eye.

    Science.gov (United States)

    Jacobs, Marc D

    2009-01-01

    A series of research topics on the eye is reviewed with the aim of illustrating how integrative and systems-biological approaches can be used to understand complex properties and functions of ocular tissues. Emphasis is placed on the diversity of physiological systems represented in the eye, and the variety of approaches required to analyze those systems, both empirically and theoretically. Modeling and empirical studies reviewed focus mainly on problems that the eye presents, in the broad areas of biomechanics and fluid dynamics from the molecular to the whole-organ scale. Attention is given to the relevance of these studies in human disease and the current potential for development of medical therapies based upon a biophysical, integrative modeling approach. The creation of a multiscale hierarchy of numerical models of the eye is proposed as an important and unifying aim of integrative eye research.

  9. Individual eye model based on wavefront aberration

    Science.gov (United States)

    Guo, Huanqing; Wang, Zhaoqi; Zhao, Qiuling; Quan, Wei; Wang, Yan

    2005-03-01

    Based on the widely used Gullstrand-Le Grand eye model, the individual human eye model has been established here, which has individual corneal data, anterior chamber depth and the eyeball depth. Furthermore, the foremost thing is that the wavefront aberration calculated from the individual eye model is equal to the eye's wavefront aberration measured with the Hartmann-shack wavefront sensor. There are four main steps to build the model. Firstly, the corneal topography instrument was used to measure the corneal surfaces and depth. And in order to input cornea into the optical model, high-order aspheric surface-Zernike Fringe Sag surface was chosen to fit the corneal surfaces. Secondly, the Hartmann-shack wavefront sensor, which can offer the Zernike polynomials to describe the wavefront aberration, was built to measure the wavefront aberration of the eye. Thirdly, the eye's axial lengths among every part were measured with A-ultrasonic technology. Then the data were input into the optical design software-ZEMAX and the crystalline lens's shapes were optimized with the aberration as the merit function. The individual eye model, which has the same wavefront aberrations with the real eye, is established.

  10. Amblyopia: What Is the Cause of Lazy Eye?

    Science.gov (United States)

    ... Stories Español Eye Health / Eye Health A-Z Amblyopia Sections Amblyopia: What Is Lazy Eye? Amblyopia: What ... Amblyopia: Lazy Eye Diagnosis Amblyopia: Lazy Eye Treatment Amblyopia: What Is the Cause of Lazy Eye? Leer ...

  11. The Toxicity of Nonsteroidal Anti-inflammatory Eye Drops against Human Corneal Epithelial Cells in Vitro.

    Science.gov (United States)

    Lee, Jong Soo; Kim, Young Hi; Park, Young Min

    2015-12-01

    This study investigated the toxicity of commercial non-steroid anti-inflammatory drug (NSAID) eye solutions against corneal epithelial cells in vitro. The biologic effects of 1/100-, 1/50-, and 1/10-diluted bromfenac sodium, pranoprofen, diclofenac sodium, and the fluorometholone on corneal epithelial cells were evaluated after 1-, 4-, 12-, and 24-hr of exposure compared to corneal epithelial cell treated with balanced salt solution as control. Cellular metabolic activity, cellular damage, and morphology were assessed. Corneal epithelial cell migration was quantified by the scratch-wound assay. Compared to bromfenac and pranoprofen, the cellular metabolic activity of diclofenac and fluorometholone significantly decreased after 12-hr exposure, which was maintained for 24-hr compared to control. Especially, at 1/10-diluted eye solution for 24-hr exposure, the LDH titers of fluorometholone and diclofenac sodium markedly increased more than those of bromfenac and pranoprofen. In diclofenac sodium, the Na(+) concentration was lower and amount of preservatives was higher than other NSAIDs eye solutions tested. However, the K(+) and Cl(-) concentration, pH, and osmolarity were similar for all NSAIDs eye solutions. Bromfenac and pranoprofen significantly promoted cell migration, and restored wound gap after 48-hr exposure, compared with that of diclofenac or fluorometholone. At 1/50-diluted eye solution for 48-hr exposure, the corneal epithelial cellular morphology of diclofenac and fluorometholone induced more damage than that of bromfenac or pranoprofen. Overall, the corneal epithelial cells in bromfenac and pranoprofen NSAID eye solutions are less damaged compared to those in diclofenac, included fluorometholone as steroid eye solution.

  12. Eye dominance predicts fMRI signals in human retinotopic cortex.

    Science.gov (United States)

    Mendola, Janine D; Conner, Ian P

    2007-02-27

    There have been many attempts to define eye dominance in normal subjects, but limited consensus exists, and relevant physiological data is scarce. In this study, we consider two different behavioral methods for assignment of eye dominance, and how well they predict fMRI signals evoked by monocular stimulation. Sighting eye dominance was assessed with two standard tests, the Porta Test, and a 'hole in hand' variation of the Miles Test. Acuity dominance was tested with a standard eye chart and with a computerized test of grating acuity. We found limited agreement between the sighting and acuity methods for assigning dominance in our individual subjects. We then compared the fMRI response generated by dominant eye stimulation to that generated by non-dominant eye, according to both methods, in 7 normal subjects. The stimulus consisted of a high contrast hemifield stimulus alternating with no stimulus in a blocked paradigm. In separate scans, we used standard techniques to label the borders of visual areas V1, V2, V3, VP, V4v, V3A, and MT. These regions of interest (ROIs) were used to analyze each visual area separately. We found that percent change in fMRI BOLD signal was stronger for the dominant eye as defined by the acuity method, and this effect was significant for areas located in the ventral occipital territory (V1v, V2v, VP, V4v). In contrast, assigning dominance based on sighting produced no significant interocular BOLD differences. We conclude that interocular BOLD differences in normal subjects exist, and may be predicted by acuity measures.

  13. Eye movements and information geometry.

    Science.gov (United States)

    Lenz, Reiner

    2016-08-01

    The human visual system uses eye movements to gather visual information. They act as visual scanning processes and can roughly be divided into two different types: small movements around fixation points and larger movements between fixation points. The processes are often modeled as random walks, and recent models based on heavy tail distributions, also known as Levý flights, have been used in these investigations. In contrast to these approaches we do not model the stochastic processes, but we will show that the step lengths of the movements between fixation points follow generalized Pareto distributions (GPDs). We will use general arguments from the theory of extreme value statistics to motivate the usage of the GPD and show empirically that the GPDs provide good fits for measured eye tracking data. In the framework of information geometry the GPDs with a common threshold form a two-dimensional Riemann manifold with the Fisher information matrix as a metric. We compute the Fisher information matrix for the GPDs and introduce a feature vector describing a GPD by its parameters and different geometrical properties of its Fisher information matrix. In our statistical analysis we use eye tracker measurements in a database with 15 observers viewing 1003 images under free-viewing conditions. We use Matlab functions with their standard parameter settings and show that a naive Bayes classifier using the eigenvalues of the Fisher information matrix provides a high classification rate identifying the 15 observers in the database.

  14. Choosing Wisely When It Comes to Eye Care: Antibiotics for Eye Injections

    Science.gov (United States)

    ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an ... healthy lifestyle choices can help you protect your vision by reducing your risk for eye diseases , eye infections and eye injuries . Partnering with your ...

  15. Choosing Wisely When It Comes to Eye Care: Antibiotics for Pink Eye

    Science.gov (United States)

    ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an ... healthy lifestyle choices can help you protect your vision by reducing your risk for eye diseases , eye infections and eye injuries . Partnering with your ...

  16. Choosing Wisely When It Comes to Eye Care: Punctal Plugs for Dry Eye

    Science.gov (United States)

    ... Eye Health A-Z Symptoms Glasses & Contacts Tips & Prevention News Ask an ... healthy lifestyle choices can help you protect your vision by reducing your risk for eye diseases, eye infections and eye injuries . Partnering with your ...

  17. Danish Rural Eye Study

    DEFF Research Database (Denmark)

    Høeg, Tracy B; Moldow, Birgitte; Ellervik, Christina

    2015-01-01

    PURPOSE: To determine the prevalence of amblyopia in Denmark before and after the initiation of the Danish national preschool vision screening programme. METHODS: In a population-based cross-sectional study, 3826 participants of the Danish General Suburban Population Study (GESUS) aged 20 years...... 45-degree retinal fundus photographs of each eye. A complete ophthalmologic examination was performed when indicated. RESULTS: The prevalence of monocular visual impairment (MVI) was 4.26% (95% CI, 3.66-4.95, n = 163). Amblyopia was the most common cause, accounting for 33%. The prevalence...... of amblyopia was 1.44% (95% CI, 1.01-1.81, n = 55), being higher among non-preschool vision screened persons compared to those who were offered (estimated 95% attendance) preschool vision screening (1.78%, n = 41, 95% CI 1.24-2.33 versus 0.44%, n = 2, 95% CI, 0.12-1.60, p = 0.024). The leading cause...

  18. Genetic defects of GDF6 in the zebrafish out of sight mutant and in human eye developmental anomalies

    Directory of Open Access Journals (Sweden)

    den Hollander Anneke I

    2010-11-01

    Full Text Available Abstract Background The size of the vertebrate eye and the retina is likely to be controlled at several stages of embryogenesis by mechanisms that affect cell cycle length as well as cell survival. A mutation in the zebrafish out of sight (out locus results in a particularly severe reduction of eye size. The goal of this study is to characterize the outm233 mutant, and to determine whether mutations in the out gene cause microphthalmia in humans. Results In this study, we show that the severe reduction of eye size in the outm233 mutant is caused by a mutation in the zebrafish gdf6a gene. Despite the small eye size, the overall retinal architecture appears largely intact, and immunohistochemical studies confirm that all major cell types are present in outm233 retinae. Subtle cell fate and patterning changes are present predominantly in amacrine interneurons. Acridine orange and TUNEL staining reveal that the levels of apoptosis are abnormally high in outm233 mutant eyes during early neurogenesis. Mutation analysis of the GDF6 gene in 200 patients with microphthalmia revealed amino acid substitutions in four of them. In two patients additional skeletal defects were observed. Conclusions This study confirms the essential role of GDF6 in the regulation of vertebrate eye size. The reduced eye size in the zebrafish outm233 mutant is likely to be caused by a transient wave of apoptosis at the onset of neurogenesis. Amino acid substitutions in GDF6 were detected in 4 (2% of 200 patients with microphthalmia. In two patients different skeletal defects were also observed, suggesting pleitrophic effects of GDF6 variants. Parents carrying these variants are asymptomatic, suggesting that GDF6 sequence alterations are likely to contribute to the phenotype, but are not the sole cause of the disease. Variable expressivity and penetrance suggest a complex non-Mendelian inheritance pattern where other genetic factors may influence the outcome of the phenotype.

  19. The Colossal Cosmic Eye

    Science.gov (United States)

    2005-09-01

    Eighty-five million years ago on small planet Earth, dinosaurs ruled, ignorant of their soon-to-come demise in the great Jurassic extinction, while mammals were still small and shy creatures. The southern Andes of Bolivia, Chile, and Argentina were not yet formed and South America was still an island continent. Eighty-five million years ago, our Sun and its solar system was 60,000 light years away from where it now stands [1]. Eighty-five million years ago, in another corner of the Universe, light left the beautiful spiral galaxy NGC 1350, for a journey across the universe. Part of this light was recorded at the beginning of the year 2000 AD by ESO's Very Large Telescope, located on the 2,600m high Cerro Paranal in the Chilean Andes on planet Earth. Astronomers classify NGC 1350 as an Sa(r) type galaxy, meaning it is a spiral with large central regions. In fact, NGC 1350 lies at the border between the broken-ring spiral type and a grand design spiral with two major outer arms. It is about 130,000 light-years across and, hence, is slightly larger than our Milky Way. The rather faint and graceful outer arms originate at the inner main ring and can be traced for almost half a circle when they each meet the opposite arm, giving the impression of completing a second outer ring, the "eye". The arms are given a blue tint as a result of the presence of very young and massive stars. The amount of dust, seen as small fragmented dust spirals in the central part of the galaxy and producing a fine tapestry that bear resemblance with blood vessels in the eye, is also a signature of the formation of stars.

  20. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life.

    Directory of Open Access Journals (Sweden)

    Niels Lynnerup

    Full Text Available BACKGROUND: Lens crystallines are special proteins in the eye lens. Because the epithelial basement membrane (lens capsule completely encloses the lens, desquamation of aging cells is impossible, and due to the complete absence of blood vessels or transport of metabolites in this area, there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14C content from the atmospheric carbon dioxide. The (14C content of the lens proteins thus reflects the atmospheric content of (14C when the lens crystallines were formed. Precise radiocarbon dating is made possible by comparing the (14C content of the lens crystallines to the so-called bomb pulse, i.e. a plot of the atmospheric (14C content since the Second World War, when there was a significant increase due to nuclear-bomb testing. Since the change in concentration is significant even on a yearly basis this allows very accurate dating. METHODOLOGY/PRINCIPAL FINDINGS: Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close relationship may be further expressed as a mathematical model, which takes into account the timing of the crystalline formation. CONCLUSIONS/SIGNIFICANCE: Such a life-long permanence of human tissue has hitherto only been described for dental enamel. In confront to dental enamel it must be held in mind that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the (14C content of various tissues may be used to assess turnover rates and degree of substitution (for example for brain cell DNA. Potential targets may be nervous tissues in terms of senile or pre

  1. OCT Study of Mechanical Properties Associated with Trabecular Meshwork and Collector Channel Motion in Human Eyes

    Science.gov (United States)

    Xin, Chen; Johnstone, Murray; Wang, Ningli; Wang, Ruikang K.

    2016-01-01

    We report the use of a high-resolution optical coherence tomography (OCT) imaging platform to identify and quantify pressure-dependent aqueous outflow system (AOS) tissue relationships and to infer mechanical stiffness through examination of tissue properties in ex vivo human eyes. Five enucleated human eyes are included in this study, with each eye prepared with four equal-sized quadrants, each encompassing 90 degrees of the limbal circumference. In radial limbal segments perfusion pressure within Schlemm’s canal (SC) is controlled by means of a perfusion cannula inserted into the canal lumen, while the other end of the cannula leads to a reservoir at a height that can control the pressure in the cannula. The OCT system images the sample with a spatial resolution of about 5 μm from the trabecular meshwork (TM) surface. Geometric parameters are quantified from the 2D OCT images acquired from the sample subjected to controlled changes in perfusion pressures; parameters include area and height of the lumen of SC, collector channel entrances (CCE) and intrascleral collector channels (ISCC). We show that 3D OCT imaging permits the identification of 3-D relationships of the SC, CCE and ISCC lumen dimensions. Collagen flaps or leaflets are found at CCE that are attached or hinged at only one end, whilst the flaps are connected to the TM by cylindrical structures spanning SC. Increasing static SC pressures resulted in SC lumen enlargement with corresponding enlargement of the CCE and ISCC lumen. Pressure-dependent SC lumen area and height changes are significant at the 0.01 levels for ANOVA, and at the 0.05 for both polynomial curves and Tukey paired comparisons. Dynamic measurements demonstrate a synchronous increase in SC, CCE and ISCC lumen height in response to pressure changes from 0 to 10, 30 or 50 mm Hg, respectively, and the response time is within the 50-millisecond range. From the measured SC volume and corresponding IOP values, we demonstrate that an

  2. Eye Movements in Gaze Interaction

    DEFF Research Database (Denmark)

    Møllenbach, Emilie; Hansen, John Paulin; Lillholm, Martin

    2013-01-01

    Gaze as a sole input modality must support complex navigation and selection tasks. Gaze interaction combines specific eye movements and graphic display objects (GDOs). This paper suggests a unifying taxonomy of gaze interaction principles. The taxonomy deals with three types of eye movements: fix...

  3. Childhood Eye Diseases and Conditions

    Science.gov (United States)

    ... have a fever. More serious preseptal or orbital cellulitis infections can cause decreased vision, an inability to move the eye, and the appearance of the eye being pushed forward. What to do: Both forms of cellulitis are serious conditions that require urgent medical attention. ...

  4. Compensatory eye movements in mice

    NARCIS (Netherlands)

    A.M. van Alphen (Adriaan)

    2002-01-01

    textabstractThis thesis will address the generation of compensatory eye movements in naturally mutated or genetically modified mice. The reason for generating compensatory eye movements is solely related to the requirements for good vision. In a subject moving through its environment the projection

  5. Eye tracking for visual marketing

    NARCIS (Netherlands)

    Wedel, M.; Pieters, R.

    2008-01-01

    We provide the theory of visual attention and eye-movements that serves as a basis for evaluating eye-tracking research and for discussing salient and emerging issues in visual marketing. Motivated from its rising importance in marketing practice and its potential for theoretical contribution, we

  6. Miniature curved artificial compound eyes.

    Science.gov (United States)

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L'Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A; Franceschini, Nicolas

    2013-06-04

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories.

  7. Conjunctivitis (Pink Eye) in Newborns

    Science.gov (United States)

    ... Work Adenovirus Non-Polio Enterovirus Parent Portal Conjunctivitis (Pink Eye) in Newborns Language: English Español (Spanish) Recommend ... recién nacidos Newborns with symptoms of conjunctivitis (pink eye) should see a doctor right away. Neonatal ...

  8. Eye Movements in Gaze Interaction

    DEFF Research Database (Denmark)

    Møllenbach, Emilie; Hansen, John Paulin; Lillholm, Martin

    2013-01-01

    Gaze as a sole input modality must support complex navigation and selection tasks. Gaze interaction combines specific eye movements and graphic display objects (GDOs). This paper suggests a unifying taxonomy of gaze interaction principles. The taxonomy deals with three types of eye movements...

  9. Adaptive correction of human-eye aberrations in a subjective feedback loop.

    Science.gov (United States)

    Vdovin, G; Loktev, M; Simonov, A; Kijko, V; Volkov, S

    2005-04-01

    An adaptive optical system with a subjective feedback loop is used to improve the visual acuity and to determine the aberrations of the human eye. Corrections of as many as 12 low-order aberration modes were made, based on the perceived sharpness of the test object observed through the adaptive optical system. The acuity of vision was improved by adjustment of the weights of the orthogonal modes produced by a deformable mirror. Objective measurements of the correcting aspherical figures, obtained in independent subjective correction cycles for one person, demonstrated good repeatability. Participants in the study with strong ocular aberrations reported moderate to significant improvement of their visual acuity, estimated with the U.S. Air Force 1951 acuity chart.

  10. Particulate matter contamination in the corneal stroma of severe eye burns in humans

    Energy Technology Data Exchange (ETDEWEB)

    Schrage, N.F.; Reim, M.; Burchard, W.G. (Department of Ophthalmology, RWTH-Aachen (Germany))

    1990-01-01

    Corneal buttons obtained from keratoplasty were examined by energy dispersive x-ray analysis (EDXA) combined with scanning electron microscopy (SEM). This method enables to assay the mineral composition of minute parts of tissue samples identified in SEM images. Samples were cut from paraffin embedded corneae, deparaffinized in xylol, dried in aceton, critical-point desiccated, covered by evaporating with a thin layer of carbon and examined by SEM. In healthy human donor eyes, only some iron particles had been found. In the 22 patients samples high amounts of different particles were identified, materials from rubber stoppers, chromesteel, titanium pigments, talcum, barium and glass. Furthermore a lot of different metal particles containing varying amounts of Na, Mg, Al, Si, P, S, Cl, K, Ca, Fe, Cu, Cr, Zn, La and Ce were detected. Some particles may be caused by the initial trauma, others by therapy. Such contaminations might have supported leucocyte and fibrocyte invasion increasing the inflammatory reaction in the burnt cornea.

  11. Radiocarbon dating of the human eye lens crystallines reveal proteins without carbon turnover throughout life

    DEFF Research Database (Denmark)

    Lynnerup, Niels; Kjeldsen, Henrik; Heegaard, Steffen

    2008-01-01

    , there is no subsequent remodelling of these fibers, nor removal of degraded lens fibers. Human tissue ultimately derives its (14)C content from the atmospheric carbon dioxide. The (14)C content of the lens proteins thus reflects the atmospheric content of (14)C when the lens crystallines were formed. Precise radiocarbon...... on a yearly basis this allows very accurate dating. METHODOLOGY/PRINCIPAL FINDINGS: Our results allow us to conclude that the crystalline formation in the lens nucleus almost entirely takes place around the time of birth, with a very small, and decreasing, continuous formation throughout life. The close...... that the eye lens is a soft structure, subjected to almost continuous deformation, due to lens accommodation, yet its most important constituent, the lens crystalline, is never subject to turnover or remodelling once formed. The determination of the (14)C content of various tissues may be used to assess...

  12. Human exposure to acrolein: Time-dependence and individual variation in eye irritation.

    Science.gov (United States)

    Claeson, Anna-Sara; Lind, Nina

    2016-07-01

    The aim of the study was to examine the time dependence on sensory irritation detection following exposure to threshold levels of acrolein, in humans. The exposures occurred in an exposure chamber and the subjects were breathing fresh air through a mask that covered the nose and mouth. All participants participated in four exposure conditions, of which three consisted of a mixture of acrolein and heptane and one of only heptane. Exposure to acrolein at a concentration half of the TLV-C lead to sensory irritation. The perceived sensory irritation resulted in both increased detectability and sensory irritation after about 6.8min of exposure in 58% of the participants. The study confirm the previously suggested LOAEL of about 0.34mg/m(3) for eye irritation due to acrolein exposure. The sensory irritation was still significant 10min after exposure. These results have implications for risk assessment and limit setting in occupational hygiene.

  13. Computer-aided geometric modeling of the human eye and orbit.

    Science.gov (United States)

    Parshall, R F

    1991-01-01

    The author advocates, as a long-term development agenda for the profession, a shift in the working methods of medical illustrators from a two-dimensional image processing mode to a computer-aided design and drafting (CADD) mode. Existing CADD technology, which can make short work of the complex graphic construction problems of anatomical visualization, performs virtually all of its manipulations through systematic exercise of graphic geometry which illustrators tend to reduce to an intuitive, almost vestigial supplement to 2D image processing methods. The primary barrier to the immediate use of CADD is a lack of geometric database materials on anatomical component systems of the body. An on-going experimental project in modeling the human eye and orbit, utilizing a Silicon Graphics Iris workstation and Control Data Corporation's Integrated Computerized Engineering and Manufacturing (ICEM) software, exemplifies the preparatory work needed to create such database materials.

  14. Effects of Different Zernike Terms on Optical Quality and Vision of Human Eyes

    Institute of Scientific and Technical Information of China (English)

    ZHAO Hao-Xin; XU Bing; LI Jing; DAI Yun; YU Xiang; ZHANG Yu-Dong; JIANG Wen-Han

    2009-01-01

    The visual quality of human eyes is much restricted by high-order aberrations as well as low-order aberrations (defocus and astigmatism), but each term of high-order aberrations contributes differently. The visual acuity and contrast of the image on the retina can be gained by inducing aberrations to each term of high orders. Based on an adaptive optics system, the visual acuity of four subjects is tested by inducing aberrations to each Zernike term after correcting all the aberrations of the subjects. Zernike terms near the center of the Zernike tree affect visual quality more than those near the edge both theoretically and experimentally, and 0.1-μm aberration of these terms can clearly degrade the optical quality and vision. The results suggest that correcting the terms near the center of Zernike tree can improve the visual quality effectively in practice.

  15. Human regional cerebral glucose metabolism during non-rapid eye movement sleep in relation to waking.

    Science.gov (United States)

    Nofzinger, Eric A; Buysse, Daniel J; Miewald, Jean M; Meltzer, Carolyn C; Price, Julie C; Sembrat, Robert C; Ombao, Hernando; Reynolds, Charles F; Monk, Timothy H; Hall, Martica; Kupfer, David J; Moore, Robert Y

    2002-05-01

    Sleep is an essential human function. Although the function of sleep has generally been regarded to be restorative, recent data indicate that it also plays an important role in cognition. The neurobiology of human sleep is most effectively analysed with functional imaging, and PET studies have contributed substantially to our understanding of both rapid eye movement (REM) and non-rapid eye movement (NREM) sleep. In this study, PET was used to determine patterns of regional glucose metabolism in NREM sleep compared with waking. We hypothesized that brain structures related to waking cognitive function would show a persistence of function into the NREM sleep state. Fourteen healthy subjects (age range 21-49 years; 10 women, 4 men) underwent concurrent EEG sleep studies and [(18)F]fluoro-2-deoxy-D-glucose PET scans during waking and NREM sleep. Whole-brain glucose metabolism declined significantly from waking to NREM sleep. Relative decreases in regional metabolism from waking to NREM sleep occurred in wide areas of frontal, parietal, temporal and occipital association cortex, primary visual cortex, and in anterior/dorsomedial thalamus. After controlling for the whole-brain declines in absolute metabolism, relative increases in regional metabolism from waking to NREM were found bilaterally in the dorsal pontine tegmentum, hypothalamus, basal forebrain, ventral striatum, anterior cingulate cortex and extensive regions of the mesial temporal lobe, including the amygdala and hippocampus, and in the right dorsal parietal association cortex and primary somatosensory and motor cortices. The reductions in relative metabolism in NREM sleep compared with waking are consistent with prior findings from blood flow studies. The relative increases in glucose utilization in the basal forebrain, hypothalamus, ventral striatum, amygdala, hippocampus and pontine reticular formation are new observations that are in accordance with the view that NREM sleep is important to brain

  16. A new measurement method for color discrimination thresholds of human eyes based on PWM light-mixing technology

    Science.gov (United States)

    Zhang, Jiyan; Dong, Jinxin

    2016-09-01

    The color discrimination is a powerful tool for detection of eye diseases, and it is is necessary to produce different kinds of color rapidly and precisely for testing color discrimination thresholds of human eyes. Three channels' pulse-width modulation (PWM) and light-mixing technology is a new way to mixing color, and a new measurement method for color discrimination thresholds of human eyes based on PWM light-mix technology can generate kinds of color stimuli. In this study, 5 youth volunteers were measured via this equipment after the test for the stability of the device's illumination and chrominance. Though the theory of Macadam ellipses and the interleaved staircase method, a psychophysical experiment was made to study the color discrimination threshold of the human eyes around a basic color center. By analyzing the data of the chromatic ellipse and the color discrimination threshold, the result shows that each color is not uniform in a single color region and the color difference threshold of normal human is around the third Macadam ellipses. The experimental results show that the repeatability and accuracy of the observer can meet the accuracy requirements of the relevant experiments, and the data is reliable and effective, which means the measurement method is an effective way to measure the color discrimination thresholds of human visual system.

  17. Sun, UV Radiation and Your Eyes

    Science.gov (United States)

    ... Patient Stories Español Eye Health / Tips & Prevention Your Eyes and the Sun Sections The Sun, UV Radiation ... Safety Infographic The Sun, UV Radiation and Your Eyes Written by: David Turbert Aug. 28, 2014 Keep ...

  18. Dry Eyes and Glaucoma: Double Trouble

    Science.gov (United States)

    ... News About Us Donate In This Section Dry Eyes and Glaucoma: Double Trouble email Send this article ... disease bothers the patient more. What Causes Dry Eye Syndrome? Dry eye can be caused by many ...

  19. 21 CFR 886.3200 - Artificial eye.

    Science.gov (United States)

    2010-04-01

    ... OPHTHALMIC DEVICES Prosthetic Devices § 886.3200 Artificial eye. (a) Identification. An artificial eye is a... inserted in a patient's eye socket anterior to an orbital implant, or the eviscerated eyeball, for...

  20. Chance and necessity in eye evolution

    National Research Council Canada - National Science Library

    Gehring, Walter J

    2011-01-01

    ...." Recent discoveries in eye evolution are in agreement with both of these theses. They confirm Darwin's assumption of a simple eye prototype and lend strong support for the notion of a monophyletic origin of the various eye types...

  1. Eye movement monitoring of memory.

    Science.gov (United States)

    Ryan, Jennifer D; Riggs, Lily; McQuiggan, Douglas A; McQuiggan, Doug

    2010-08-15

    Explicit (often verbal) reports are typically used to investigate memory (e.g. "Tell me what you remember about the person you saw at the bank yesterday."), however such reports can often be unreliable or sensitive to response bias, and may be unobtainable in some participant populations. Furthermore, explicit reports only reveal when information has reached consciousness and cannot comment on when memories were accessed during processing, regardless of whether the information is subsequently accessed in a conscious manner. Eye movement monitoring (eye tracking) provides a tool by which memory can be probed without asking participants to comment on the contents of their memories, and access of such memories can be revealed on-line. Video-based eye trackers (either head-mounted or remote) use a system of cameras and infrared markers to examine the pupil and corneal reflection in each eye as the participant views a display monitor. For head-mounted eye trackers, infrared markers are also used to determine head position to allow for head movement and more precise localization of eye position. Here, we demonstrate the use of a head-mounted eye tracking system to investigate memory performance in neurologically-intact and neurologically-impaired adults. Eye movement monitoring procedures begin with the placement of the eye tracker on the participant, and setup of the head and eye cameras. Calibration and validation procedures are conducted to ensure accuracy of eye position recording. Real-time recordings of X,Y-coordinate positions on the display monitor are then converted and used to describe periods of time in which the eye is static (i.e. fixations) versus in motion (i.e., saccades). Fixations and saccades are time-locked with respect to the onset/offset of a visual display or another external event (e.g. button press). Experimental manipulations are constructed to examine how and when patterns of fixations and saccades are altered through different types of prior

  2. Age- and fatigue-related markers of human faces: an eye-tracking study.

    Science.gov (United States)

    Nguyen, Huy Tu; Isaacowitz, Derek M; Rubin, Peter A D

    2009-02-01

    To investigate the facial cues that are used when making judgments about how old or tired a face appears. Experimental study. Forty-seven subjects: 15 male and 32 female participants, ranging from age 18 to 30 years. Forty-eight full-face digital images of "normal-appearing" patients were collected and uploaded to an eye-tracking system. We used an Applied Science Laboratories (Bedford, MA) Eye Tracker device associated with gaze-tracking software to record and calculate the gaze and fixation of the participants' left eye as they viewed images on a computer screen. After seeing each picture, participants were asked to assess the age of the face in the picture by making a selection on a rating scale divided into 5-year intervals; for fatigue judgments we used a rating scale from 1 (not tired) to 7 (most tired). The main outcome measure was gaze fixation, as assessed by tracking the eye movements of participants as they viewed full-face digital pictures. For fatigue judgments, participants spent the most time looking at the eye region (31.81%), then the forehead and the nose regions (14.99% and 14.12%, respectively); in the eye region, participants looked most at the brows (13.1%) and lower lids (9.4%). Participants spent more time looking at the cheeks on faces they rated as least tired than they did on those they rated as most tired (t = 2.079, Peye region (27.22%) and then the forehead (15.71%) and the nose (14.30%) had the highest frequencies of interest; in the eye region, the brows and lower lids also had the highest frequencies of interest (11.40% and 8.90%, respectively). Participants looked more at the brows (t = -2.63, Peye region. Consequently, these results suggest that aesthetic or functional surgery to the eye region may be one of the most effective interventions in enhancing the appearance of an individual. The author(s) have no proprietary or commercial interest in any materials discussed in this article.

  3. A Bio-Inspired Polymeric Gradient Refractive Index (GRIN) Human Eye Lens

    Science.gov (United States)

    2012-11-19

    optical model of the crystalline lens and eye of the octopus ,” Vision Res. 39(17), 2841–2852 (1999). 5. D. E. Nilsson, L. Gislén, M. M. Coates, C...aberrations [1]. Biological examples of GRIN lenses include spherical eye lenses found in aquatic creatures such as fish, octopus , squid, and jellyfish [2–5...µATR-FTIR examination by exhuming cross sections of adjacent sheet material. The µATR-FTIR technique can map the relative composition across the cross

  4. The effect on human eye blink frequency of exposure to limonene oxidation products and methacrolein

    DEFF Research Database (Denmark)

    Nøjgaard, Jacob Klenø; Christensen, Karl Bang; Wolkoff, Peder

    2005-01-01

    to LOPs and methacrolein compared to the baseline of clean air, and the findings coincided with weak eye irritation symptoms. Lowest observed effect levels were 286 ppb methacrolein and a 10-min-old LOPs mixture of initially 92 ppb limonene and 101 ppb ozone (O3), which increased the BF comparably by 18......% (p=0.001) and 17% (p=0.003), respectively. The increase in BF was smaller, although not significantly different, during exposure to LOPs at 50% RH to 20% RH in mixtures prepared from ca. 350 ppb limonene and 300 ppb O3. LOPs may cause trigeminal stimulation and possibly eye irritation at O3...

  5. Dermal, Eye, and Oral Toxicological Evaluations.

    Science.gov (United States)

    1985-06-01

    produced no corneal opacity, iritis , hyperemia, chemosis, or discharge throughout the 72 hour observation period. This sample is non-irritating to...resolved in one eye by day 7 and in the other eye by day 14. Iritis was observed in all three eyes at 24 hours which resolved in one eye by 48 hours...other eye by day 7. Only one eye displayed iritis at 24 hours which resolved by the 72 hour observation period. Hyperemia, chemosis and discharge were

  6. Simultaneous recordings of human microsaccades and drifts with a contemporary video eye tracker and the search coil technique.

    Directory of Open Access Journals (Sweden)

    Michael B McCamy

    Full Text Available Human eyes move continuously, even during visual fixation. These "fixational eye movements" (FEMs include microsaccades, intersaccadic drift and oculomotor tremor. Research in human FEMs has grown considerably in the last decade, facilitated by the manufacture of noninvasive, high-resolution/speed video-oculography eye trackers. Due to the small magnitude of FEMs, obtaining reliable data can be challenging, however, and depends critically on the sensitivity and precision of the eye tracking system. Yet, no study has conducted an in-depth comparison of human FEM recordings obtained with the search coil (considered the gold standard for measuring microsaccades and drift and with contemporary, state-of-the art video trackers. Here we measured human microsaccades and drift simultaneously with the search coil and a popular state-of-the-art video tracker. We found that 95% of microsaccades detected with the search coil were also detected with the video tracker, and 95% of microsaccades detected with video tracking were also detected with the search coil, indicating substantial agreement between the two systems. Peak/mean velocities and main sequence slopes of microsaccades detected with video tracking were significantly higher than those of the same microsaccades detected with the search coil, however. Ocular drift was significantly correlated between the two systems, but drift speeds were higher with video tracking than with the search coil. Overall, our combined results suggest that contemporary video tracking now approaches the search coil for measuring FEMs.

  7. Simultaneous recordings of human microsaccades and drifts with a contemporary video eye tracker and the search coil technique.

    Science.gov (United States)

    McCamy, Michael B; Otero-Millan, Jorge; Leigh, R John; King, Susan A; Schneider, Rosalyn M; Macknik, Stephen L; Martinez-Conde, Susana

    2015-01-01

    Human eyes move continuously, even during visual fixation. These "fixational eye movements" (FEMs) include microsaccades, intersaccadic drift and oculomotor tremor. Research in human FEMs has grown considerably in the last decade, facilitated by the manufacture of noninvasive, high-resolution/speed video-oculography eye trackers. Due to the small magnitude of FEMs, obtaining reliable data can be challenging, however, and depends critically on the sensitivity and precision of the eye tracking system. Yet, no study has conducted an in-depth comparison of human FEM recordings obtained with the search coil (considered the gold standard for measuring microsaccades and drift) and with contemporary, state-of-the art video trackers. Here we measured human microsaccades and drift simultaneously with the search coil and a popular state-of-the-art video tracker. We found that 95% of microsaccades detected with the search coil were also detected with the video tracker, and 95% of microsaccades detected with video tracking were also detected with the search coil, indicating substantial agreement between the two systems. Peak/mean velocities and main sequence slopes of microsaccades detected with video tracking were significantly higher than those of the same microsaccades detected with the search coil, however. Ocular drift was significantly correlated between the two systems, but drift speeds were higher with video tracking than with the search coil. Overall, our combined results suggest that contemporary video tracking now approaches the search coil for measuring FEMs.

  8. An Interactive Method for Teaching Anatomy of the Human Eye for Medical Students in Ophthalmology Clinical Rotations

    Science.gov (United States)

    Kivell, Tracy L.; Doyle, Sara K.; Madden, Richard H.; Mitchell, Terry L.; Sims, Ershela L.

    2009-01-01

    Much research has shown the benefits of additional anatomical learning and dissection beyond the first year of medical school human gross anatomy, all the way through postgraduate medical training. We have developed an interactive method for teaching eye and orbit anatomy to medical students in their ophthalmology rotation at Duke University…

  9. Oxygen Tension in the Aqueous Humor of Human Eyes under Different Oxygenation Conditions

    Directory of Open Access Journals (Sweden)

    Farideh Sharifipour

    2013-01-01

    Full Text Available Purpose: To measure oxygen tension in the aqueous humor of human eyes under different oxygenation conditions. Methods: This prospective comparative interventional case series consisted of two parts. In the first part, 120 consecutive patients scheduled for cataract surgery were randomized into group I (control group in which surgery was performed under local anesthesia inhaling 21% oxygen; group II in whom general anesthesia using 50% oxygen was employed; and group III receiving general anesthesia with 100% oxygen. After aspirating 0.2 ml aqueous humor under sterile conditions, the aqueous sample and a simultaneously drawn arterial blood sample were immediately analyzed using a blood gas analyzer. In part II the same procedures were performed in 10 patients after fitting a contact lens and patching the eye for 20 minutes (group IV and in 10 patients after transcorneal delivery of oxygen at a flow rate of 5 L/min (group V. Results: Mean aqueous PO2 in groups I, II and III was 112.3±6.2, 141.1±20.4, and 170.1±27 mmHg, respectively (P values <0.001 and mean arterial PO2 was 85.7±7.9, 184.6±46, and 379.1±75.9 mmHg, respectively (P values <0.001. Aqueous PO2 was 77.2±9.2 mmHg in group IV and 152.3±10.9 mmHg in group V (P values <0.001. There was a significant correlation between aqueous and blood PO2 (r=0.537, P<0.001. The contribution of atmospheric oxygen to aqueous PO2 was 23.7%. Conclusion: Aqueous oxygen tension is mostly dependent on the systemic circulation and in part on the atmosphere. Increasing inspiratory oxygen and transcorneal oxygen delivery both increase aqueous PO2 levels.

  10. Optical imaging of the chorioretinal vasculature in the living human eye.

    Science.gov (United States)

    Kim, Dae Yu; Fingler, Jeff; Zawadzki, Robert J; Park, Susanna S; Morse, Lawrence S; Schwartz, Daniel M; Fraser, Scott E; Werner, John S

    2013-08-27

    Detailed visualization of microvascular changes in the human retina is clinically limited by the capabilities of angiography imaging, a 2D fundus photograph that requires an intravenous injection of fluorescent dye. Whereas current angiography methods enable visualization of some retinal capillary detail, they do not adequately reveal the choriocapillaris or other microvascular features beneath the retina. We have developed a noninvasive microvascular imaging technique called phase-variance optical coherence tomography (pvOCT), which identifies vasculature three dimensionally through analysis of data acquired with OCT systems. The pvOCT imaging method is not only capable of generating capillary perfusion maps for the retina, but it can also use the 3D capabilities to segment the data in depth to isolate vasculature in different layers of the retina and choroid. This paper demonstrates some of the capabilities of pvOCT imaging of the anterior layers of choroidal vasculature of a healthy normal eye as well as of eyes with geographic atrophy (GA) secondary to age-related macular degeneration. The pvOCT data presented permit digital segmentation to produce 2D depth-resolved images of the retinal vasculature, the choriocapillaris, and the vessels in Sattler's and Haller's layers. Comparisons are presented between en face projections of pvOCT data within the superficial choroid and clinical angiography images for regions of GA. Abnormalities and vascular dropout observed within the choriocapillaris for pvOCT are compared with regional GA progression. The capability of pvOCT imaging of the microvasculature of the choriocapillaris and the anterior choroidal vasculature has the potential to become a unique tool to evaluate therapies and understand the underlying mechanisms of age-related macular degeneration progression.

  11. Computer Assisted Diagnoses for Red Eye (CADRE

    Directory of Open Access Journals (Sweden)

    Muhammad Zubair Asghar

    2009-11-01

    Full Text Available This paper introduces an expert System (ES named as “CADRE-Computer Assisted Diagnoses for Red Eye. Mostly the remote areas of the population are deprived of the facilities of having experts in eye disease. So it is the need of the day to store the expertise of Eye specialists in computers through using ES technology. This ES is a rule-based Expert System that assists in red-eye diagnosis and treatment. The knowledge acquired from literature review and human experts of the specific domain was used as a base for analysis, diagnosis and recommendations. CADRE evaluates the risk factors of 20 eye diseases and works just like an ophthalmologist, which will be useful for students, doctors and researchers as well as to patients. This expert system (ES was developed through using ESTA, VISUAL BASIC, MS-EXCEL, Seagate Crystal Reports and Image Styler. This ES is not limited to the Red-eye diseases but can be extended to all types of eye-diseases.

  12. Characterization of human retinal vessel arborisation in normal and amblyopic eyes using multifractal analysis

    Directory of Open Access Journals (Sweden)

    Stefan Tălu

    2015-10-01

    Full Text Available AIM:To characterize the human retinal vessel arborisation in normal and amblyopic eyes using multifractal geometry and lacunarity parameters.METHODS:Multifractal analysis using a box counting algorithm was carried out for a set of 12 segmented and skeletonized human retinal images, corresponding to both normal (6 images and amblyopia states of the retina (6 images.RESULTS:It was found that the microvascular geometry of the human retina network represents geometrical multifractals, characterized through subsets of regions having different scaling properties that are not evident in the fractal analysis. Multifractal analysis of the amblyopia images (segmented and skeletonized versions show a higher average of the generalized dimensions (Dq for q=0, 1, 2 indicating a higher degree of the tree-dimensional complexity associated with the human retinal microvasculature network whereas images of healthy subjects show a lower value of generalized dimensions indicating normal complexity of biostructure. On the other hand, the lacunarity analysis of the amblyopia images (segmented and skeletonized versions show a lower average of the lacunarity parameter Λ than the corresponding values for normal images (segmented and skeletonized versions.CONCLUSION:The multifractal and lacunarity analysis may be used as a non-invasive predictive complementary tool to distinguish amblyopic subjects from healthy subjects and hence this technique could be used for an early diagnosis of patients with amblyopia.

  13. Characterization of human retinal vessel arborisation in normal and amblyopic eyes using multifractal analysis.

    Science.gov (United States)

    Tălu, Stefan; Vlăduţiu, Cristina; Lupaşcu, Carmen A

    2015-01-01

    To characterize the human retinal vessel arborisation in normal and amblyopic eyes using multifractal geometry and lacunarity parameters. Multifractal analysis using a box counting algorithm was carried out for a set of 12 segmented and skeletonized human retinal images, corresponding to both normal (6 images) and amblyopia states of the retina (6 images). It was found that the microvascular geometry of the human retina network represents geometrical multifractals, characterized through subsets of regions having different scaling properties that are not evident in the fractal analysis. Multifractal analysis of the amblyopia images (segmented and skeletonized versions) show a higher average of the generalized dimensions (Dq ) for q=0, 1, 2 indicating a higher degree of the tree-dimensional complexity associated with the human retinal microvasculature network whereas images of healthy subjects show a lower value of generalized dimensions indicating normal complexity of biostructure. On the other hand, the lacunarity analysis of the amblyopia images (segmented and skeletonized versions) show a lower average of the lacunarity parameter Λ than the corresponding values for normal images (segmented and skeletonized versions). The multifractal and lacunarity analysis may be used as a non-invasive predictive complementary tool to distinguish amblyopic subjects from healthy subjects and hence this technique could be used for an early diagnosis of patients with amblyopia.

  14. An eye for the I: Preferential attention to the eyes of ingroup members.

    Science.gov (United States)

    Kawakami, Kerry; Williams, Amanda; Sidhu, David; Choma, Becky L; Rodriguez-Bailón, Rosa; Cañadas, Elena; Chung, Derek; Hugenberg, Kurt

    2014-07-01

    Human faces, and more specifically the eyes, play a crucial role in social and nonverbal communication because they signal valuable information about others. It is therefore surprising that few studies have investigated the impact of intergroup contexts and motivations on attention to the eyes of ingroup and outgroup members. Four experiments investigated differences in eye gaze to racial and novel ingroups using eye tracker technology. Whereas Studies 1 and 3 demonstrated that White participants attended more to the eyes of White compared to Black targets, Study 2 showed a similar pattern of attention to the eyes of novel ingroup and outgroup faces. Studies 3 and 4 also provided new evidence that eye gaze is flexible and can be meaningfully influenced by current motivations. Specifically, instructions to individuate specific social categories increased attention to the eyes of target group members. Furthermore, the latter experiments demonstrated that preferential attention to the eyes of ingroup members predicted important intergroup biases such as recognition of ingroup over outgroup faces (i.e., the own-race bias; Study 3) and willingness to interact with outgroup members (Study 4). The implication of these findings for general theorizing on face perception, individuation processes, and intergroup relations are discussed.

  15. Diabetes mellitus and the eye: axial length

    OpenAIRE

    Huntjens, B.; O’Donnell, C.

    2006-01-01

    Background and aims: The refractive error of the eye is dependent on its axial length. Refractive error is known to fluctuate significantly in poorly controlled diabetic patients. Recently it has been reported that human eyes fluctuate in axial length during the day. However, this change is not detectable in all subjects, suggesting physiological influences such as diet. The purpose of this study was to investigate fluctuations in axial length and blood glucose levels (BGLs) in diabetic patie...

  16. Eye and Iris Detection Using Projection and Radial Symmetry Transform

    Institute of Scientific and Technical Information of China (English)

    XIANG Shu-lan; CAO Cheng; Aishy Amer

    2010-01-01

    This paper presents an eye and iris detection algorithm for human facial images. The authors combine three features of the eye to develop the algorithm: 1) the pixels surrounding the eyes are more variable than other parts of the face; 2) eye pixels are darker than their neighbors; 3) eyes often exhibit radial symmetric properties. Through the first feature, two rough regions of both eyes are detected on the face. Eye masks are then formed based on the second feature, and a fast radial symmetry transform is applied to the two rough regions of both eyes. Finally, accurate iris centers are located by searching the maximum value of the radial symmetry transform results. Using 450 human facial images from the Caltech face database, experiments show that the success rate of the proposed method is 91.7%. The effectiveness of the method was also verified through detection of video frames.

  17. Keeping our eyes on the eyes: the case of Arcimboldo.

    Science.gov (United States)

    Bubic, Andreja; Susac, Ana; Palmovic, Marijan

    2014-01-01

    While contemporaries often viewed his reversible composite heads as scherzi (jokes) and modem art connoisseurs as creative masterpieces, Giuseppe Arcimboldo's ingenious paintings served as inspiring stimuli for the present eye-tracking experiment. One group of participants viewed three chosen paintings in an upright, and another in an upside-down, orientation. We compared how participants viewed three selected areas of interest (AOIs) within the painting when these could, and could not, be identified as a face or distinct facial element (eyes and mouth). The obtained results indicate that the participants fixated the parts of the painting which represent faces more in the upright than in the inverted orientation. Furthermore, in the upright orientation the participants focused more on the upper AOls (eyes) than the lower AOIs (mouth). This was not the case for the inverted orientation of two paintings. In conclusion, the face inversion effect occurs even in this artistic context, and the gaze often goes where the eyes are.

  18. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    Science.gov (United States)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  19. Wartime open globe eye injuries.

    Science.gov (United States)

    Plestina-Borjan, Ivna; Medvidovic-Grubisic, Maria; Zuljan, Igor; Lakos, Venera; Miljak, Snjezana; Markovic, Irena; Ivanisevic, Milan

    2010-03-01

    Open globe injuries are the most serious eye injuries in war as in peace time. The purpose of this study is to analyze wartime open globe eye injuries in 72 patients treated at the Department of Ophthalmology, Clinical Hospital of Split from July 1991 to April 1993, during the intensive war in Croatia and Bosnia and Herzegovina, and to evaluate crucial factors responsible for the functional success of the treatment. Wartime open globe eye injuries were retrospectively analyzed in 72 patients (80 eyes) hospitalized at Clinical Hospital of Split, Department of Ophthalmology, between July 1991 and April 1993. The causes and ways of wounding, localization of wounds and presence, nature and localization of the foreign body, as well as admission time, microsurgical management and other factors contributing to poor visual outcome were studied. Standard international classification of ocular traumas (the Birmingham Eye Trauma Terminology and the International Ocular Trauma Classification) was used for the classified and graded injuries. Open globe eye injuries amounted to 52.65% of all war injuries to the eyes. Bilateral injuries were found in eight patients (11.11%). The most frequent cause of the injures were fragments of explosive devices (more than two-thirds). Most of the patients were admitted to the hospital within 24 hours of the injury. Using current microsurgical techniques, the attempt was made to achieve not only anatomical but also functional recovery already in the primary treatment. In 30 eyes (37.50%) final visual acuity amounted to more than 0.1, and in 22 eyes (27.50%) it reached 0.5. There was a statistically significant correlation between admission within the first 12 hours and postoperative improved visual acuity (chi(2) = 4.53; p = 0.033). Statistically significantly better visual acuity was found in patients with lesions limited to the anterior segment of the eye. Primary enucleation or evisceration was performed only exceptionally: one enucleation

  20. The eyes of LITENING

    Science.gov (United States)

    Moser, Eric K.

    2016-05-01

    LITENING is an airborne system-of-systems providing long-range imaging, targeting, situational awareness, target tracking, weapon guidance, and damage assessment, incorporating a laser designator and laser range finders, as well as non-thermal and thermal imaging systems, with multi-sensor boresight. Robust operation is at a premium, and subsystems are partitioned to modular, swappable line-replaceable-units (LRUs) and shop-replaceable-units (SRUs). This presentation will explore design concepts for sensing, data storage, and presentation of imagery associated with the LITENING targeting pod. The "eyes" of LITENING are the electro-optic sensors. Since the initial LITENING II introduction to the US market in the late 90s, as the program has evolved and matured, a series of spiral functional improvements and sensor upgrades have been incorporated. These include laser-illuminated imaging, and more recently, color sensing. While aircraft displays are outside of the LITENING system, updates to the available viewing modules have also driven change, and resulted in increasingly effective ways of utilizing the targeting system. One of the latest LITENING spiral upgrades adds a new capability to display and capture visible-band color imagery, using new sensors. This is an augmentation to the system's existing capabilities, which operate over a growing set of visible and invisible colors, infrared bands, and laser line wavelengths. A COTS visible-band camera solution using a CMOS sensor has been adapted to meet the particular needs associated with the airborne targeting use case.

  1. Eyes of Things

    Directory of Open Access Journals (Sweden)

    Oscar Deniz

    2017-05-01

    Full Text Available Embedded systems control and monitor a great deal of our reality. While some “classic” features are intrinsically necessary, such as low power consumption, rugged operating ranges, fast response and low cost, these systems have evolved in the last few years to emphasize connectivity functions, thus contributing to the Internet of Things paradigm. A myriad of sensing/computing devices are being attached to everyday objects, each able to send and receive data and to act as a unique node in the Internet. Apart from the obvious necessity to process at least some data at the edge (to increase security and reduce power consumption and latency, a major breakthrough will arguably come when such devices are endowed with some level of autonomous “intelligence”. Intelligent computing aims to solve problems for which no efficient exact algorithm can exist or for which we cannot conceive an exact algorithm. Central to such intelligence is Computer Vision (CV, i.e., extracting meaning from images and video. While not everything needs CV, visual information is the richest source of information about the real world: people, places and things. The possibilities of embedded CV are endless if we consider new applications and technologies, such as deep learning, drones, home robotics, intelligent surveillance, intelligent toys, wearable cameras, etc. This paper describes the Eyes of Things (EoT platform, a versatile computer vision platform tackling those challenges and opportunities.

  2. Visuomotor transformations for eye-hand coordination.

    Science.gov (United States)

    Henriques, D Y P; Medendorp, W P; Khan, A Z; Crawford, J D

    2002-01-01

    In recent years the scientific community has come to appreciate that the early cortical representations for visually guided arm movements are probably coded in a visual frame, i.e. relative to retinal landmarks. While this scheme accounts for many behavioral and neurophysiological observations, it also poses certain problems for manual control. For example, how are these oculocentric representations updated across eye movements, and how are they then transformed into useful commands for accurate movements of the arm relative to the body? Also, since we have two eyes, which is used as the reference point in eye-hand alignment tasks like pointing? We show that patterns of errors in human pointing suggest that early oculocentric representations for arm movement are remapped relative to the gaze direction during each saccade. To then transform these oculocentric representations into useful commands for accurate movements of the arm relative to the body, the brain correctly incorporates the three-dimensional, rotary geometry of the eyes when interpreting retinal images. We also explore the possibility that the eye-hand coordination system uses a strategy like ocular dominance, but switches alignment between the left and right eye in order to maximize eye-hand coordination in the best field of view. Finally, we describe the influence of eye position on eye-hand alignment, and then consider how head orientation influences the linkage between oculocentric visual frames and bodycentric motor frames. These findings are framed in terms of our 'conversion-on-demand' model, which suggests a virtual representation of egocentric space, i.e. one in which only those representations selected for action are put through the complex visuomotor transformations required for interaction with actual objects in personal space.

  3. 21 CFR 880.5270 - Neonatal eye pad.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neonatal eye pad. 880.5270 Section 880.5270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... § 880.5270 Neonatal eye pad. (a) Identification. A neonatal eye pad is an opaque device used to...

  4. The eyes of man as a photic bisensor system

    NARCIS (Netherlands)

    Verheijen, F.J.; Fingal, J.A.

    1982-01-01

    Non-patterned photic stimulation of the eyes of human subjects was obtained by homogeneous illumination of the closed eyes. The subjects perceived a difference between the stimulation intensity of the left and of the right eye as a field of view consisting of a bright and a dark half, adjoined acros

  5. The eyes of man as a photic bisensor system

    NARCIS (Netherlands)

    Verheijen, F.J.; Fingal, J.A.

    1982-01-01

    Non-patterned photic stimulation of the eyes of human subjects was obtained by homogeneous illumination of the closed eyes. The subjects perceived a difference between the stimulation intensity of the left and of the right eye as a field of view consisting of a bright and a dark half, adjoined acros

  6. Visual attention to plain and ornamented human bodies: an eye-tracking study.

    Science.gov (United States)

    Wohlrab, Silke; Fink, Bernhard; Pyritz, Lennart W; Rahlfs, Moritz; Kappeler, Peter M

    2007-06-01

    Signaling mate quality through visual adornments is a common phenomenon in animals and humans. However, humans are probably the only species who applies artificial ornaments. Such deliberate alterations of the skin, e.g., tattoos and scarring patterns, have been discussed by researchers as potential handicap signals, but there is still very little information about a potential biological signaling value of body modification. In this study eye-tracking was employed to investigate the signaling value of tattoos and other body modification. Measurement of gaze duration of 50 individuals while watching plain, scarred, accessorized, and tattooed bodies of artificial human images indicated that participants looked significantly longer at tattooed than at scarred, accessorized, and plain bodies. Generally, male participants paid more attention to tattooed stimuli of both sexes. More detailed analyses showed that particularly female tattooed stimuli were looked at longer. These findings are discussed within an evolutionary framework by suggesting that tattoos might have some signaling value which influences the perception of both male and female conspecifics and may hence also affect mating decisions.

  7. Eye-head stabilization mechanism for a humanoid robot tested on human inertial data

    DEFF Research Database (Denmark)

    Vannucci, Lorenzo; Falotico, Egidio; Tolu, Silvia;

    2016-01-01

    they keep the image stationary on the retina. In this work we present the first complete model of eye-head stabilization based on the coordination of VCR and VOR. The model is provided with learning and adaptation capabilities based on internal models. Tests on a simulated humanoid platform replicating...

  8. Investigation of High Power, Pulsed, Neodymium-YAG Lasers for Correcting Opacities of the Human Eye.

    Science.gov (United States)

    1982-06-01

    system to breaking vitreous strands, a condition consisting of cellular strands in the vitreous humor, generally caused by disease or trauma to the eye...input beam and the output plane is at a distance -z2 from the waist of the output beam. From the ABCD law of Gaussian optics, A (-Z1 + jZR1) +B[-5

  9. Remote control of mobile robots through human eye gaze: the design and evaluation of an interface

    Science.gov (United States)

    Latif, Hemin Omer; Sherkat, Nasser; Lotfi, Ahmad

    2008-10-01

    Controlling mobile robots remotely requires the operator to monitor the status of the robot through some sort of feedback. Assuming a vision based feedback system is used the operator is required to closely monitor the images while navigating the robot in real time. This will engage the eyes and the hands of the operator. Since the eyes are engaged in the monitoring task anyway, their gaze can be used to navigate the robot in order to free the hands of the operator. However, the challenge here lies in developing an interaction interface that enables an intuitive distinction to be made between monitoring and commanding. This paper presents a novel means of constructing a user interface to meet this challenge. A range of solutions are constructed by augmenting the visual feedback with command regions to investigate the extent to which a user can intuitively control the robot. An experimental platform comprising a mobile robot together with cameras and eye-gaze system is constructed. The design of the system allows control of the robot, control of onboard cameras and control of the interface through eye-gaze. A number of tasks are designed to evaluate the proposed solutions. This paper presents the design considerations and the results of the evaluation. Overall it is found that the proposed solutions provide effective means of successfully navigating the robot for a range of tasks.

  10. Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

    Science.gov (United States)

    Zhai, Yi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; He, Yuanqing; Chang, Shengjiang

    2014-01-01

    An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced into the eye model along visual axis. Moreover, three kinds of individual eye models are established to investigate the impacts of higher-order aberrations, chromatic aberration (LCA+TCA), LCA and TCA on vision under the photopic condition, respectively. Results show that for most human eyes, the impact of chromatic aberration on vision is much stronger than that of higher-order aberrations, and the impact of LCA in chromatic aberration dominates. The impact of TCA is approximately equal to that of normal level higher-order aberrations and it can be ignored when LCA exists.

  11. What the human eye tells the brain: a new approach toward a hardware-based modeling of mental functions

    Science.gov (United States)

    Lauinger, N.

    2007-09-01

    A better understanding of intelligent information processing in human vision can be reached through a closer look at the macro- and micro-hardware available in the hierarchy of cortical processors along the main visual pathway connecting the retina, the CGL (corpus geniculatum laterale) and area V1 (cortical visual area 17). The building of the eye is driven by the brain and the engineering of the main visual pathway back to V1 seems to be driven by the eyes. The human eye offers to the brain much more intelligent information about the outer visible world than a camera producing flat 2D images on a CCD. Intelligent processing of visual information in human vision - a strong cooperation between eyes and brain - relays on axes related symmetry operations relevant for navigation in 4D spectral space-times, on a hierarchy of dynamically balanced equilibrium states, on diffractive-optical transformation of the Visible into RGB space, on range mapping based on RGB data (monocular and binocular 3D vision), on illuminant-adaptive optical correlations of local onto global RGB data (color constancy performances) and on invariant fourier-optical log-polar processing of image data (generic object classification; identification of objects). These performances are more compatible with optical processing of modern diffractive-optical sensors and interference-optical correlators than with cameras. The R+D project NAMIROS (Nano- and Micro-3D gratings for Optical Sensors) [8], coordinated by an interdisciplinary team of specialists at Corrsys 3D Sensors AG, describes the roadmap towards a technical realization of outstanding high-tech performances corresponding to human eye-brain co-processing.

  12. Dose conversion coefficients for electron exposure of the human eye lens

    Energy Technology Data Exchange (ETDEWEB)

    Behrens, R [Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig (Germany); Dietze, G [Paracelsusstrasse 7, D-38116 Braunschweig (Germany); Zankl, M [Helmholtz Zentrum Muenchen, Ingolstaedter Landstrasse 1, D-85764 Neuherberg (Germany)], E-mail: rolf.behrens@ptb.de

    2009-07-07

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity H{sub p}(0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity H{sub p}(3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0 deg. and 45 deg. are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  13. Dose conversion coefficients for electron exposure of the human eye lens

    Science.gov (United States)

    Behrens, R.; Dietze, G.; Zankl, M.

    2009-07-01

    Recent epidemiological studies suggest a rather low dose threshold (below 0.5 Gy) for the induction of a cataract of the eye lens. Some other studies even assume that there is no threshold at all. Therefore, protection measures have to be optimized and current dose limits for the eye lens may be reduced in the future. Two questions arise from this situation: first, which dose quantity is related to the risk of developing a cataract, and second, which personal dose equivalent quantity is appropriate for monitoring this dose quantity. While the dose equivalent quantity Hp(0.07) has often been seen as being sufficiently accurate for monitoring the dose to the lens of the eye, this would be questionable in the case when the dose limits were reduced and, thus, it may be necessary to generally use the dose equivalent quantity Hp(3) for this purpose. The basis for a decision, however, must be the knowledge of accurate conversion coefficients from fluence to equivalent dose to the lens. This is especially important for low-penetrating radiation, for example, electrons. Formerly published values of conversion coefficients are based on quite simple models of the eye. In this paper, quite a sophisticated model of the eye including the inner structure of the lens was used for the calculations and precise conversion coefficients for electrons with energies between 0.2 MeV and 12 MeV, and for angles of radiation incidence between 0° and 45° are presented. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are up to 1000 times smaller for electron energies below 1 MeV, nearly equal at 1 MeV and above 4 MeV, and by a factor of 1.5 larger at about 1.5 MeV electron energy.

  14. Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.

    Science.gov (United States)

    LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W

    2017-02-27

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Control and Functions of Fixational Eye Movements

    Science.gov (United States)

    Rucci, Michele; Poletti, Martina

    2016-01-01

    Humans and other species explore a visual scene by rapidly shifting their gaze 2-3 times every second. Although the eyes may appear immobile in the brief intervals in between saccades, microscopic (fixational) eye movements are always present, even when attending to a single point. These movements occur during the very periods in which visual information is acquired and processed and their functions have long been debated. Recent technical advances in controlling retinal stimulation during normal oculomotor activity have shed new light on the visual contributions of fixational eye movements and their degree of control. The emerging body of evidence, reviewed in this article, indicates that fixational eye movements are important components of the strategy by which the visual system processes fine spatial details, enabling both precise positioning of the stimulus on the retina and encoding of spatial information into the joint space-time domain.

  16. Eye Movements When Viewing Advertisements

    Directory of Open Access Journals (Sweden)

    Emily eHiggins

    2014-03-01

    Full Text Available In this selective review, we examine key findings on eye movements when viewing advertisements. We begin with a brief, general introduction to the properties and neural underpinnings of saccadic eye movements. Next, we provide an overview of eye movement behavior during reading, scene perception, and visual search, since each of these activities is, at various times, involved in viewing ads. We then review the literature on eye movements when viewing print ads and warning labels (of the kind that appear on alcohol and tobacco ads, before turning to a consideration of advertisements in dynamic media (television and the Internet. Finally, we propose topics and methodological approaches that may prove to be useful in future research.

  17. Applications of lobster eye optics

    Science.gov (United States)

    Hudec, R.; Pina, L.; Inneman, A.; Tichy, V.

    2015-05-01

    Applications of wide field Lobster Eye X ray telescopes are presented and discussed. The wide field X ray optics was originally proposed for use in X-ray astronomy, but there are numerous other application areas as well.

  18. Juvenile eye growth, when completed?

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Christensen, Anders S; Fledelius, Christian

    2014-01-01

    PURPOSE: To test Sorsby's classical statement of axial eye growth as completed at the age of 13 years, with a view also to differentiating between basic eye growth and juvenile elongation associated with eventual refractive change towards myopia. METHODS: (i) A total of 160 healthy eyes close...... was preferred for conventional ultrasound oculometry due to its extreme repeatability of measuring values, thus making it well fitted for evaluating very small differences. In particular, this had bearing for the decelerating end phase of growth in the longitudinal investigation. RESULTS: Sorby's statement...... about age 13 as general limit found support from the cross-sectional data, which suggested stable emmetropic eye size from about 11-12 years, with an average apparently outgrown male emmetropic value of 23.5 mm versus females' 22.9 mm. The longitudinal data, however, showed emmetropic growth also beyond...

  19. Eye movements when viewing advertisements

    Science.gov (United States)

    Higgins, Emily; Leinenger, Mallorie; Rayner, Keith

    2013-01-01

    In this selective review, we examine key findings on eye movements when viewing advertisements. We begin with a brief, general introduction to the properties and neural underpinnings of saccadic eye movements. Next, we provide an overview of eye movement behavior during reading, scene perception, and visual search, since each of these activities is, at various times, involved in viewing ads. We then review the literature on eye movements when viewing print ads and warning labels (of the kind that appear on alcohol and tobacco ads), before turning to a consideration of advertisements in dynamic media (television and the Internet). Finally, we propose topics and methodological approaches that may prove to be useful in future research. PMID:24672500

  20. Eyes on the Solar System

    Data.gov (United States)

    National Aeronautics and Space Administration — Eyes on the Solar System is a software package developed by NASA Jet Propulsion Laboratory and the California Institute of Technology using data provided by NASA's...

  1. Head and eye Echoencephalogram (image)

    Science.gov (United States)

    ... to test for abnormalities in the eye. The ultrasound helps evaluate the farthest part of the eyeball when there are cataracts. The test may help diagnose retinal detachment or other disorders and evaluate orbital lesions and intraocular lesions.

  2. A Note on Eye Movement

    CERN Document Server

    Bolina, O; Bolina, Oscar

    1998-01-01

    In a simplified fashion, the motion of the eyeball in its orbit consists of rotations around a fixed point. Therefore, this motion can be described in terms of the Euler's angles of rigid body dynamics. However, there is a physiological constraint in the motion of the eye which reduces to two its degrees of freedom. This paper reviews the basic features of the kinematics of the eye and the laws governing its motion.

  3. Talking with eye injury patients

    Directory of Open Access Journals (Sweden)

    Helen Roberts

    2016-01-01

    Full Text Available Patients with an eye injury are usually in pain and very frightened. They need a gentle, reassuring approach. Your first task is to assess the general state of your patient. If they are alert and orientated and their general health is good, you can continue to examine them in the eye department. If their immediate general health is at risk, you will have to address this first.

  4. 1st Workshop on Eye Tracking and Visualization

    CERN Document Server

    Chuang, Lewis; Fisher, Brian; Schmidt, Albrecht; Weiskopf, Daniel

    2017-01-01

    This book discusses research, methods, and recent developments in the interdisciplinary field that spans research in visualization, eye tracking, human-computer interaction, and psychology. It presents extended versions of papers from the First Workshop on Eye Tracking and Visualization (ETVIS), which was organized as a workshop of the IEEE VIS Conference 2015. Topics include visualization and visual analytics of eye-tracking data, metrics and cognitive models, eye-tracking experiments in the context of visualization interfaces, and eye tracking in 3D and immersive environments. The extended ETVIS papers are complemented by a chapter offering an overview of visualization approaches for analyzing eye-tracking data and a chapter that discusses electrooculography (EOG) as an alternative of acquiring information about eye movements. Covering scientific visualization, information visualization, and visual analytics, this book is a valuable resource for eye-tracking researchers within the visualization community.

  5. Eye-movement study and human performance using telepathology virtual slides: implications for medical education and differences with experience.

    Science.gov (United States)

    Krupinski, Elizabeth A; Tillack, Allison A; Richter, Lynne; Henderson, Jeffrey T; Bhattacharyya, Achyut K; Scott, Katherine M; Graham, Anna R; Descour, Michael R; Davis, John R; Weinstein, Ronald S

    2006-12-01

    A core skill in diagnostic pathology is light microscopy. Remarkably little is known about human factors that affect the proficiency of pathologists as light microscopists. The cognitive skills of pathologists have received relatively little attention in comparison with the large literature on human performance studies in radiology. One reason for this lack of formal visual search studies in pathology has been the physical restrictions imposed by the close positioning of a microscope operator's head to the microscope's eyepieces. This blocks access to the operator's eyes and precludes assessment of the microscopist's eye movements. Virtual slide microscopy now removes this barrier and opens the door for studies on human factors and visual search strategies in light microscopy. The aim of this study was to assess eye movements of medical students, pathology residents, and practicing pathologists examining virtual slides on a digital display monitor. Whole histopathology glass slide digital images, so-called virtual slides, of 20 consecutive breast core biopsy cases were used in a retrospective study. These high-quality virtual slides were produced with an array-microscope equipped DMetrix DX-40 ultrarapid virtual slide processor (DMetrix, Tucson, Ariz). Using an eye-tracking device, we demonstrated for the first time that when a virtual slide reader initially looks at a virtual slide his or her eyes are very quickly attracted to regions of interest (ROIs) within the slide and that these ROIs are likely to contain diagnostic information. In a matter of seconds, critical decisions are made on the selection of ROIs for further examination at higher magnification. We recorded: (1) the time virtual slide readers spent fixating on self-selected locations on the video monitor; (2) the characteristics of the ways the eyes jumped between fixation locations; and (3) x and y coordinates for each virtual slide marking the sites the virtual slide readers manually selected for

  6. Eye casualty services in London

    Science.gov (United States)

    Smith, H B; Daniel, C S; Verma, S

    2013-01-01

    The combined pressures of the European Working Time Directive, 4 h waiting time target, and growing rates of unplanned hospital attendances have forced a major consolidation of eye casualty departments across the country, with the remaining units seeing a rapid increase in demand. We examine the effect of these changes on the provision of emergency eye care in Central London, and see what wider lessons can be learned. We surveyed the managers responsible for each of London's 8 out-of-hours eye casualty services, analysed data on attendance numbers, and conducted detailed interviews with lead clinicians. At London's two largest units, Moorfields Eye Hospital and the Western Eye Hospital, annual attendance numbers have been rising at 7.9% per year (to 76 034 patients in 2010/11) and 9.6% per year (to 31 128 patients in 2010/11), respectively. Using Moorfields as a case study, we discuss methods to increase capacity and efficiency in response to this demand, and also examine some of the unintended consequences of service consolidation including patients travelling long distances to geographically inappropriate units, and confusion over responsibility for out-of-hours inpatient cover. We describe a novel ‘referral pathway' developed to minimise unnecessary travelling and delay for patients, and propose a forum for the strategic planning of London's eye casualty services in the future. PMID:23370420

  7. Eye lrritation caused by Formaldehyde as an Indoor AIr Pollution—A Controlled Human Exposure Experiment

    Institute of Scientific and Technical Information of China (English)

    YANGXU; ZHANGYUN-PING; 等

    2001-01-01

    The present study focuses on health assessment of wood based panels which are widely used in interior decoration practices over the recent years in China.Formaldehyde has been i-dentified as chemical indicator of (IAO) and an indoor air pollutant.To test its health effects experiment was undertaken.Method: A small environmental test chamber(60/L) was used as the genertor of emission gas from new panels,and was operating at a temperature of 22.7±0.6℃ and a humidity of 44.4±2.5% with an air exchange rate of 1.0±0.15h-1.On the three experimental days the values of product lodaing in chamber were 4,2 and 6m2/m3,respectively,Eight people were selected randomly from the students and employees of Wuhan Health and Anti-epidemic Station as subjects,with an average age of 21.9±5.9 years,and a gender ratio of 1:1,and two of them were smokders(one male and one female).The subjects' eyes were exposed to formaldehyde through a pair of googles.Each goggle had its flow inlet and outlet,and connected to chamber exhaust of emission gas and to an exhaust from the room.The exposure time was very short,just 5 minutes and the formaldehyde doses were at 1.65±0.01,2.99±0.07and 4.31±0.02ppm,A6-mm linear visual analogue rating scales was used to measure the intensity of sensory eye irritation and a video tape racorder was used to record eye blinking frequency.Results:the results demonstrated that tests of sensory eye irritation and eye blinking can be used for materials testing,and that a dose-effect as well as a time-variance of the effect can be measured.Conclusion:The tests showed that eye irritation was perceived at all of the three levels.±

  8. Eye Health in Sports and Recreation

    Science.gov (United States)

    ... Recreation Eye Injuries at Work Fireworks Eye Safety Sports Eye Injuries by the Numbers — Infographic Five Steps to Safer ... protection. High-Risk Sports For all age groups, sports-related eye injuries occur most frequently in baseball, basketball and racquet ...

  9. A New Method to Assess Eye Dominance

    Science.gov (United States)

    Valle-Inclan, Fernando; Blanco, Manuel J.; Soto, David; Leiros, Luz

    2008-01-01

    People usually show a stable preference for one of their eyes when monocular viewing is required ("sighting dominance") or under dichoptic stimulation conditions ("sensory eye-dominance"). Current procedures to assess this "eye dominance" are prone to error. Here we present a new method that provides a continuous measure of eye dominance and…

  10. Eye Movement Disorders in Dyslexia. Final Report.

    Science.gov (United States)

    Festinger, Leon; And Others

    Eye movements of 18 male and seven female dyslexic children and 10 normal children were evaluated to determine if eye movement disorders may be the cause of some of the symptoms associated with dyslexia. Data on eye movements were collected while Ss moved their eyes from one fixation point to another in a nonreading situation. Errors in vertical…

  11. A novel EOG/EEG hybrid human-machine interface adopting eye movements and ERPs: application to robot control.

    Science.gov (United States)

    Ma, Jiaxin; Zhang, Yu; Cichocki, Andrzej; Matsuno, Fumitoshi

    2015-03-01

    This study presents a novel human-machine interface (HMI) based on both electrooculography (EOG) and electroencephalography (EEG). This hybrid interface works in two modes: an EOG mode recognizes eye movements such as blinks, and an EEG mode detects event related potentials (ERPs) like P300. While both eye movements and ERPs have been separately used for implementing assistive interfaces, which help patients with motor disabilities in performing daily tasks, the proposed hybrid interface integrates them together. In this way, both the eye movements and ERPs complement each other. Therefore, it can provide a better efficiency and a wider scope of application. In this study, we design a threshold algorithm that can recognize four kinds of eye movements including blink, wink, gaze, and frown. In addition, an oddball paradigm with stimuli of inverted faces is used to evoke multiple ERP components including P300, N170, and VPP. To verify the effectiveness of the proposed system, two different online experiments are carried out. One is to control a multifunctional humanoid robot, and the other is to control four mobile robots. In both experiments, the subjects can complete tasks effectively by using the proposed interface, whereas the best completion time is relatively short and very close to the one operated by hand.

  12. Perceptual and not physical eye contact elicits pupillary dilation.

    Science.gov (United States)

    Honma, Motoyasu; Tanaka, Yasuto; Osada, Yoshihisa; Kuriyama, Kenichi

    2012-01-01

    Eye contact is important to share communication during social interactions. However, how accurately humans can perceive the gaze direction of others toward themselves and whether pupils dilate when humans consciously or unconsciously perceive own eyes are looked by others remain unclear. In this study, we examined the relationship between the explicit perception of looking into each other's eyes and the implicit physiological response of pupillary dilation by using an original face-to-face method. We found that humans do not correctly detect the gaze direction of others. Furthermore, one's pupils dilated when one gazed at others' eyes. Awareness of others' gaze on one's eyes, rather than the actual focusing of other's gaze on one's eyes, enhanced pupillary dilation. Therefore, physiological responses are caused not when people actually look into each other's gaze, but when the consciousness of other's gaze is activated, which suggests that eye contact often involves one-way communication.

  13. The construction of individual eye model based on eye's wavefront aberration measurement

    Science.gov (United States)

    Wang, Zhao-Qi; Guo, Huan-Qing

    2005-08-01

    Based on the widely used Gullstrand-Le Grand eye model, the individual human eye model has been established here, which has individual corneal data, anterior chamber depth and the eyeball depth. Furthermore the foremost thing is that the wavefront aberration calculated from the individual eye model is equal to the eye's wavefront aberration measured with the Hartmann-shack wavefront sensor. There were four main steps to build the model. Firstly, the corneal topography instrument was used to measure the corneal surfaces and depth. And in order to input cornea into the optical model, high order aspheric surface-Zernike Fringe Sag surface was chosen to fit the corneal surfaces. Secondly, the Hartmann-shack wavefront sensor, which can offer the Zernike polynomials to describe the wavefront aberration, was built to measure the wavefront aberration of the eye. Thirdly, the eye's axial lengths among every part were measured with A-ultrasonic technology. Then the data were input into the optical design software -ZEMAX and the crystalline lens's shapes were optimized with the aberration as the merit function. The individual eye model, which has the same wavefront aberrations with the real eye, is established.

  14. Dynamic eye phantom for retinal oximetry measurements

    Science.gov (United States)

    Lemaillet, Paul; Ramella-Roman, Jessica C.

    2009-11-01

    Measurements of oxygen saturation and flow in the retina can yield information about eye health and the onset of eye pathologies such as diabetic retinopathy. Recently, we developed a multiaperture camera that uses the division of the retinal image into several wavelength-sensitive subimages to compute retinal oxygen saturation. The calibration of such instruments is particularly difficult due to the layered structure of the eye and the lack of alternative measurement techniques. For this purpose, we realize an in vitro model of the human eye composed of a lens, the retina vessel, and three layers: the choroid, the retinal pigmented epithelium, and the sclera. The retinal vessel is modeled with a microtube connected to a micropump and a hemoglobin reservoir in a closed circulatory system. Hemoglobin oxygenation in the vessel could be altered using a reversible fuel cell. The sclera is represented by a Spectralon slab. The optical properties of the other layers are mimicked using titanium dioxide as a scatterer, ink as an absorber, and epoxy as a supporting structure. The optical thickness of each layer of the eye phantom is matched to each respective eye layer.

  15. Visual Analytics for Mobile Eye Tracking.

    Science.gov (United States)

    Kurzhals, Kuno; Hlawatsch, Marcel; Seeger, Christof; Weiskopf, Daniel

    2017-01-01

    The analysis of eye tracking data often requires the annotation of areas of interest (AOIs) to derive semantic interpretations of human viewing behavior during experiments. This annotation is typically the most time-consuming step of the analysis process. Especially for data from wearable eye tracking glasses, every independently recorded video has to be annotated individually and corresponding AOIs between videos have to be identified. We provide a novel visual analytics approach to ease this annotation process by image-based, automatic clustering of eye tracking data integrated in an interactive labeling and analysis system. The annotation and analysis are tightly coupled by multiple linked views that allow for a direct interpretation of the labeled data in the context of the recorded video stimuli. The components of our analytics environment were developed with a user-centered design approach in close cooperation with an eye tracking expert. We demonstrate our approach with eye tracking data from a real experiment and compare it to an analysis of the data by manual annotation of dynamic AOIs. Furthermore, we conducted an expert user study with 6 external eye tracking researchers to collect feedback and identify analysis strategies they used while working with our application.

  16. Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

    Institute of Scientific and Technical Information of China (English)

    ZHAO Hao-Xin; XU Bing; XUE Li-Xia; DAI Yun; LIU Qian; RAO Xue-Jun

    2008-01-01

    @@ Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We caJculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are diffcult to accomplish in practice, and gives confdence to correct high-order aberrations out of the laboratory.

  17. Femtosecond laser-induced cavitations in the lens of the human eye

    DEFF Research Database (Denmark)

    Kessel, Line; Nymand, Jose; Harbst, Michael;

    2007-01-01

    Ultrafast femtosecond lasers are used increasingly for a wide range of medicai purposes. The immediate tissue response to pulses above a certain threshold is optically or laser induced breakdown, which is often visible as gas-filled cavities that persist for some time. In the present study, we at...... laser effects in the len s that have a potential for therapeutic application and treatment of eye dis ease though further studies are needed to shed light on the nature of the formation of delayed cavitations.......Ultrafast femtosecond lasers are used increasingly for a wide range of medicai purposes. The immediate tissue response to pulses above a certain threshold is optically or laser induced breakdown, which is often visible as gas-filled cavities that persist for some time. In the present study, we...... attempted to define the cavitation threshold in the human lens in vitro using multiphoton effects base d on radiation from a femtosecond 800 nm Ti:Sapphire laser. Cavitations were observed from pulse energy densities exceeding 16 mJ/cm2, but only after several minutes of exposure and not as a result...

  18. Femtosecond laser-induced cavitations in the lens of the human eye

    DEFF Research Database (Denmark)

    Kessel, Line; Nymand, Jose; Harbst, Michael;

    Ultrafast femtosecond lasers are used increasingly for a wide range of medicai purposes. The immediate tissue response to pulses above a certain threshold is optically or laser induced breakdown, which is often visible as gas-filled cavities that persist for some time. In the present study, we at...... laser effects in the len s that have a potential for therapeutic application and treatment of eye dis ease though further studies are needed to shed light on the nature of the formation of delayed cavitations.......Ultrafast femtosecond lasers are used increasingly for a wide range of medicai purposes. The immediate tissue response to pulses above a certain threshold is optically or laser induced breakdown, which is often visible as gas-filled cavities that persist for some time. In the present study, we...... attempted to define the cavitation threshold in the human lens in vitro using multiphoton effects base d on radiation from a femtosecond 800 nm Ti:Sapphire laser. Cavitations were observed from pulse energy densities exceeding 16 mJ/cm2, but only after several minutes of exposure and not as a result...

  19. Ab interno trabeculectomy: ultrastructural evidence and early tissue response in a human eye.

    Science.gov (United States)

    Ferrari, Ettore; Ortolani, Fulvia; Petrelli, Lucia; Contin, Magali; Pognuz, Derri Roman; Marchini, Maurizio; Bandello, Francesco

    2007-10-01

    To report the results of ultrastructural analysis of the postoperative effects of ab interno trabeculectomy in a human eye. Department of Ophthalmology, Palmanova Hospital, Palmanova, Udine, Italy. A 60-year-old woman with cataract and glaucoma had enucleation for a choroidal melanoma 10 days after ab interno trabeculectomy combined with phacoemulsification. A second ab interno trabeculectomy was performed after enucleation to evaluate the outcomes of the previous trabeculectomy. Light and transmission electron microscopy analyses were performed on samples excised from areas (1) not subjected to a procedure (control samples), (2) that had ab interno trabeculectomy before enucleation, and (3) that had ab interno trabeculectomy immediately after enucleation. Control samples showed normal trabecular features. Semithin sections of all ab interno trabeculectomy samples showed full-thickness removal of trabeculum segments, with Schlemm's canal lumen opening into the anterior chamber and apparent preservation of the adjacent structures. On ultrathin sections of samples that had ab interno trabeculectomy before enucleation, the endothelium lining the outer wall of Schlemm's canal and other angle components showed intact ultrastructural features. In trabecular beams that were not removed, the extracellular matrix appeared to have maintained its fine texture and was free of activated fibroblasts or leucocyte infiltrates. Observations confirm that ab interno trabeculectomy causes direct communication between Schlemm's canal lumen and the anterior chamber in vivo and immediately after enucleation during the early postoperative period. The absence of an evident inflammatory reaction in the examined case should be considered with caution because of possible tumor-induced immune suppression.

  20. Anterior corneal and internal contributions to peripheral aberrations of human eyes

    Science.gov (United States)

    Atchison, David A.

    2004-03-01

    Anterior corneal and internal component contributions to overall peripheral aberrations of five human eyes were determined, based on corneal topography and overall aberration measurements. Anterior corneal position and orientation (tilt) were referenced to the line of sight. Ray tracing was performed through the anterior cornea for 6-mm-diameter pupils at angles out to 40° in both the temporal and the nasal visual fields. In general, both component and overall Zernike aberrations were greater for the nasal than for the temporal visual field. In general, the anterior corneal aberration components were considerably higher than the overall aberrations across the visual field and were balanced to a considerable degree by the internal ocular aberration components. The component and overall levels of Zernike third-order aberrations showed linear trends away from the fixation axis, and the component levels of Zernike fourth-order aberrations showed quadratic trends away from the fixation axis. The second-order, but not higher-order, aberration components were susceptible to the choice of image radius of curvature, while disregarding corneal position and orientation affected second- and higher-order aberration components.

  1. Wide field OCT based microangiography in living human eye (Conference Presentation)

    Science.gov (United States)

    Zhang, Qinqin; Chen, Chieh-Li; Chu, Zhongdi; Zhang, Anqi; An, Lin; Durbin, Mary; Sharma, Utkarsh; Rosenfeld, Philip J.; Wang, Ruikang K.

    2016-03-01

    To investigate the application of optical microangiography (OMAG) in living human eye. Patients with different macular diseases were recruited, including diabetic retinopathy (DR), geographic atrophy (GA), retinitis pigmentosa (RP), and venous occlusion, et al. Wide field OCT angiography images can be generated by montage scanning protocol based on the tracking system. OMAG algorithm based on complex differentiation was used to extract the blood flow and removed the bulk motion by 2D cross-correlation method. The 3D angiography was segmented into 3 layers in the retina and 2 layers in the choroid. The en-face maximum projection was used to obtain 2-dimensional angiograms of different layers coded with different colors. Flow and structure images were combined for cross-sectional view. En face OMAG images of different macular diseases showed a great agreement with FA. Meanwhile, OMAG gave more distinct vascular network visions that were less affected by hemorrhage and leakage. The MAs were observed in both superficial and middle retinal layers based on OMAG angiograms in different layers of DR patients. The contour line of FAZ was extracted as well, which can be quantitative the retinal diseases. For GA patient, the damage of RPE layer enhanced the penetration of light and enabled the acquisition of choriocapillaries and choroidal vessels. The wide field OMAG angiogram enabled the capability of capturing the entire geographic atrophy. OMAG provides depth-resolved information and detailed vascular images of DR and GA patients, providing a better visualization of vascular network compared to FA.

  2. Drugs affecting the eye.

    Science.gov (United States)

    Taylor, F

    1985-08-01

    This discussion reviews drugs that affect the eye, including antihyperglycemic agents; corticosteroids; antirheumatic drugs (quinolines, indomethacin, and allopurinol); psychiatric drugs (phenothiazine, thioridazine, and chlorpromazine); drugs used in cardiology (practolol, amiodarone, and digitalis gylcosides); drugs implicated in optic neuritis and atrophy, drugs with an anticholinergic action; oral contraceptives (OCs); and topical drugs and systemic effects. Refractive changes, either myopic or hypermetropic, can occur as a result of hyperglycemia, and variation in vision is sometimes a presenting symptom in diabetes mellitus. If it causes a change in the refraction, treatment of hyperglycemia almost always produces a temporary hypermetropia. A return to the original refractive state often takes weeks, sometimes months. There is some evidence that patients adequately treated with insulin improve more rapidly than those taking oral medication. Such patients always should be referred for opthalmological evaluation as other factors might be responsible, but it might not be possible to order the appropriate spectacle correction for some time. The most important ocular side effect of the systemic adiministration of corticosteroids is the formation of a posterior subcapsular cataract. Glaucoma also can result from corticosteroids, most often when they are applied topically. Corticosteroids have been implicated in the production of benign intracranial hypertension, which is paradoxical because they also are used in its treatment. The most important side effect of drugs such as chloroquine and hydroxychloroquine is an almost always irreversible maculopathy with resultant loss of central vision. Corneal and retinal changes similar to those caused by the quinolines have been reported with indomethacin, but there is some question about a cause and effect relationship. The National Registry of Drug Induced Ocular Side Effects in the US published 30 case histories of

  3. Blue eye color in humans may be caused by a perfectly associated founder mutation in a regulatory element located within the HERC2 gene inhibiting OCA2 expression

    DEFF Research Database (Denmark)

    Eiberg, Hans; Troelsen, Jesper; Boyd, Mette

    2008-01-01

    The human eye color is a quantitative trait displaying multifactorial inheritance. Several studies have shown that the OCA2 locus is the major contributor to the human eye color variation. By linkage analysis of a large Danish family, we finemapped the blue eye color locus to a 166 Kbp region...... within the HERC2 gene. By association analyses, we identified two SNPs within this region that were perfectly associated with the blue and brown eye colors: rs12913832 and rs1129038. Of these, rs12913832 is located 21.152 bp upstream from the OCA2 promoter in a highly conserved sequence in intron 86...... of HERC2. The brown eye color allele of rs12913832 is highly conserved throughout a number of species. As shown by a Luciferase assays in cell cultures, the element significantly reduces the activity of the OCA2 promoter and electrophoretic mobility shift assays demonstrate that the two alleles bind...

  4. [Eye contact effects: A therapeutic issue?

    Science.gov (United States)

    Baltazar, M; Conty, L

    2016-12-01

    The perception of a direct gaze - that is, of another individual's gaze directed at the observer that leads to eye contact - is known to influence a wide range of cognitive processes and behaviors. We stress that these effects mainly reflect positive impacts on human cognition and may thus be used as relevant tools for therapeutic purposes. In this review, we aim (1) to provide an exhaustive review of eye contact effects while discussing the limits of the dominant models used to explain these effects, (2) to illustrate the therapeutic potential of eye contact by targeting those pathologies that show both preserved gaze processing and deficits in one or several functions that are targeted by the eye contact effects, and (3) to propose concrete ways in which eye contact could be employed as a therapeutic tool. (1) We regroup the variety of eye contact effects into four categories, including memory effects, activation of prosocial behavior, positive appraisals of self and others and the enhancement of self-awareness. We emphasize that the models proposed to account for these effects have a poor predictive value and that further descriptions of these effects is needed. (2) We then emphasize that people with pathologies that affect memory, social behavior, and self and/or other appraisal, and self-awareness could benefit from eye contact effects. We focus on depression, autism and Alzheimer's disease to illustrate our proposal. To our knowledge, no anomaly of eye contact has been reported in depression. Patients suffering from Alzheimer disease, at the early and moderate stage, have been shown to maintain a normal amount of eye contact with their interlocutor. We take into account that autism is controversial regarding whether gaze processing is preserved or altered. In the first view, individuals are thought to elude or omit gazing at another's eyes while in the second, individuals are considered to not be able to process the gaze of others. We adopt the first stance

  5. Lipid-protein interactions in plasma membranes of fiber cells isolated from the human eye lens.

    Science.gov (United States)

    Raguz, Marija; Mainali, Laxman; O'Brien, William J; Subczynski, Witold K

    2014-03-01

    The protein content in human lens membranes is extremely high, increases with age, and is higher in the nucleus as compared with the cortex, which should strongly affect the organization and properties of the lipid bilayer portion of intact membranes. To assess these effects, the intact cortical and nuclear fiber cell plasma membranes isolated from human lenses from 41- to 60-year-old donors were studied using electron paramagnetic resonance spin-labeling methods. Results were compared with those obtained for lens lipid membranes prepared from total lipid extracts from human eyes of the same age group [Mainali, L., Raguz, M., O'Brien, W. J., and Subczynski, W. K. (2013) Biochim. Biophys. Acta]. Differences were considered to be mainly due to the effect of membrane proteins. The lipid-bilayer portions of intact membranes were significantly less fluid than lipid bilayers of lens lipid membranes, prepared without proteins. The intact membranes were found to contain three distinct lipid environments termed the bulk lipid domain, boundary lipid domain, and trapped lipid domain. However, the cholesterol bilayer domain, which was detected in cortical and nuclear lens lipid membranes, was not detected in intact membranes. The relative amounts of bulk and trapped lipids were evaluated. The amount of lipids in domains uniquely formed due to the presence of membrane proteins was greater in nuclear membranes than in cortical membranes. Thus, it is evident that the rigidity of nuclear membranes is greater than that of cortical membranes. Also the permeability coefficients for oxygen measured in domains of nuclear membranes were significantly lower than appropriate coefficients measured in cortical membranes. Relationships between the organization of lipids into lipid domains in fiber cells plasma membranes and the organization of membrane proteins are discussed.

  6. Trustworthy-Looking Face Meets Brown Eyes

    OpenAIRE

    Karel Kleisner; Lenka Priplatova; Peter Frost; Jaroslav Flegr

    2013-01-01

    We tested whether eye color influences perception of trustworthiness. Facial photographs of 40 female and 40 male students were rated for perceived trustworthiness. Eye color had a significant effect, the brown-eyed faces being perceived as more trustworthy than the blue-eyed ones. Geometric morphometrics, however, revealed significant correlations between eye color and face shape. Thus, face shape likewise had a significant effect on perceived trustworthiness but only for male faces, the eff...

  7. Experimental investigation of vitreous humour motion within a human eye model

    Energy Technology Data Exchange (ETDEWEB)

    Repetto, Rodolfo [Dipartimento di Ingegneria delle Strutture, delle Acque e del Terreno, University of L' Aquila (Italy); Stocchino, Alessandro [Dipartimento di Ingegneria Ambientale, University of Genova (Italy); Cafferata, Chiara [Dipartimento di Ingegneria Ambientale, University of Genova (Italy)

    2005-10-07

    We present an experimental study of the vitreous motion induced by saccadic eye movements. A magnified model of the vitreous chamber has been employed, consisting of a spherical cavity carved in a perspex cylindrical container, which is able to rotate with a prescribed time law. Care has been taken to correctly reproduce real saccadic eye movements. The spherical cavity is filled with glycerol and the flow field is measured on the equatorial plane orthogonal to the axis of rotation, through the PIV technique. Visualizations of the fully three-dimensional flow suggest that it essentially occurs on planes perpendicular to the axis of rotation, the motion orthogonal to such planes being smaller by three to four orders of magnitude. Theoretical results, based on a simplified solution, are in very good agreement with the experimental findings. The maximum value of the shear stress at the wall, which is thought to play a possibly important role in the pathogenesis of retinal detachment, does not significantly depend on the amplitude of saccadic movements. This suggests that relatively small eye rotations, being much more frequent than large movements, are mainly responsible for vitreous stresses on the retina. Results also illustrate the dependence of the maximum shear stress at the wall from the vitreous viscosity.

  8. In Vivo Non-Invasive Measurement of Young's Modulus of Elasticity in Human Eyes: A Feasibility Study.

    Science.gov (United States)

    Sit, Arthur J; Lin, Shuai-Chun; Kazemi, Arash; McLaren, Jay W; Pruet, Christopher M; Zhang, Xiaoming

    2017-08-28

    Abnormal ocular biomechanical properties may be important for understanding the risk of glaucoma. However, there are no clinical methods for measuring standard material properties in patients. In this feasibility study we demonstrated proof-of-principle for a novel method, ultrasound surface wave elastography (USWE), to determine the in vivo Young's modulus of elasticity of corneas in normal human eyes. Twenty eyes of 10 healthy subjects (mean age 51.4±7.2;±SD, range 43-64 y) were studied. A spherical-tipped probe (3-mm diameter) was placed on closed eyelids and generated a gentle harmonic vibration at 100 Hz for 0.1 second. Wave speed propagation in the cornea was measured by USWE, and Young's modulus was calculated from the wave speed. Associations between Young's modulus and intraocular pressure (IOP), age, central corneal thickness, and axial length were explored by Pearson correlation. Statistical significance was determined by using generalized estimating equation models to account for possible correlation between fellow eyes. Mean IOP was 12.8±2.7 mm Hg. Mean wave speed in the cornea was 1.82±0.10 m/s. Young's modulus of elasticity was 696±113 kPa and was correlated with IOP (r=0.57; P=0.004), but none of the other variables (P>0.1). USWE is a novel non-invasive technique for measuring ocular biomechanical properties. Corneal Young's modulus in normal eyes is associated with IOP, consistent with measurements in cadaver eyes. Further work is needed to determine elasticity in other ocular tissues, particularly the sclera, and if elasticity is altered in glaucoma patients.

  9. Characterization of the vitreous body of the human eye using a cyanine dye as a spectral and fluorescent probe

    Science.gov (United States)

    Panova, Ina G.; Tatikolov, Alexander S.

    2009-02-01

    We used one of cyanine dyes as a spectral and fluorescent probe in the study of the composition of the extracellular matrix of the human eye (its vitreous body). Owing to the unique ability of the dye to bind to collagens and human serum albumin, we revealed the simultaneous presence of both types of biomacromolecules in the vitreous body. The formation of the dye complex with human serum albumin leads to appearance of a long-wavelength absorption band (~612 nm) and a steep rise of fluorescence, whereas in the presence of collagens the dye forms J-aggregates with a longer-wavelength absorption band (640-660 nm) and moderate fluorescence. In this work we studied the composition of the human fetus vitreous body and its dynamics from 9 to 31 gestation weeks. On the basis of the data obtained by this method, we may assume that albumin, being a carrier protein, probably provides the vitreous body and surrounding tissues with necessary growth factors, hormones, lipids, vitamins, and some other biomolecules. The data show that the dye is promising not only for study of albumin functions in eye development, but also for characterization of some eye diseases and for analysis of other extracellular media.

  10. Apnea-induced rapid eye movement sleep disruption impairs human spatial navigational memory.

    Science.gov (United States)

    Varga, Andrew W; Kishi, Akifumi; Mantua, Janna; Lim, Jason; Koushyk, Viachaslau; Leibert, David P; Osorio, Ricardo S; Rapoport, David M; Ayappa, Indu

    2014-10-29

    Hippocampal electrophysiology and behavioral evidence support a role for sleep in spatial navigational memory, but the role of particular sleep stages is less clear. Although rodent models suggest the importance of rapid eye movement (REM) sleep in spatial navigational memory, a similar role for REM sleep has never been examined in humans. We recruited subjects with severe obstructive sleep apnea (OSA) who were well treated and adherent with continuous positive airway pressure (CPAP). Restricting CPAP withdrawal to REM through real-time monitoring of the polysomnogram provides a novel way of addressing the role of REM sleep in spatial navigational memory with a physiologically relevant stimulus. Individuals spent two different nights in the laboratory, during which subjects performed timed trials before and after sleep on one of two unique 3D spatial mazes. One night of sleep was normally consolidated with use of therapeutic CPAP throughout, whereas on the other night, CPAP was reduced only in REM sleep, allowing REM OSA to recur. REM disruption via this method caused REM sleep reduction and significantly fragmented any remaining REM sleep without affecting total sleep time, sleep efficiency, or slow-wave sleep. We observed improvements in maze performance after a night of normal sleep that were significantly attenuated after a night of REM disruption without changes in psychomotor vigilance. Furthermore, the improvement in maze completion time significantly positively correlated with the mean REM run duration across both sleep conditions. In conclusion, we demonstrate a novel role for REM sleep in human memory formation and highlight a significant cognitive consequence of OSA. Copyright © 2014 the authors 0270-6474/14/3414571-07$15.00/0.

  11. Dorsal eye selector pannier (pnr) suppresses the eye fate to define dorsal margin of the Drosophila eye

    Science.gov (United States)

    Oros, Sarah M.; Tare, Meghana; Kango-Singh, Madhuri; Singh, Amit

    2010-01-01

    Axial patterning is crucial for organogenesis. During Drosophila eye development, dorso-ventral (DV) axis determination is the first lineage restriction event. The eye primordium begins with a default ventral fate, on which the dorsal eye fate is established by expression of the GATA-1 transcription factor pannier (pnr). Earlier, it was suggested that loss of pnr function induces enlargement in the dorsal eye due to ectopic equator formation. Interestingly, we found that in addition to regulating DV patterning, pnr suppresses the eye fate by downregulating the core retinal determination genes eyes absent (eya), sine oculis (so) and dacshund (dac) to define the dorsal eye margin. We found that pnr acts downstream of Ey and affect the retinal determination pathway by suppressing eya. Further analysis of the “eye suppression” function of pnr revealed that this function is likely mediated through suppression of the homeotic gene teashirt (tsh) and is independent of homothorax (hth), a negative regulator of eye. Pnr expression is restricted to the peripodial membrane on the dorsal eye margin, which gives rise to head structures around the eye, and pnr is not expressed in the eye disc proper that forms the retina. Thus, pnr has dual function, during early developmental stages pnr is involved in axial patterning whereas later it promotes the head specific fate. These studies will help in understanding the developmental regulation of boundary formation of the eye field on the dorsal eye margin. PMID:20691679

  12. Method for 3D Image Representation with Reducing the Number of Frames based on Characteristics of Human Eyes

    Directory of Open Access Journals (Sweden)

    Kohei Arai

    2016-10-01

    Full Text Available Method for 3D image representation with reducing the number of frames based on characteristics of human eyes is proposed together with representation of 3D depth by changing the pixel transparency. Through experiments, it is found that the proposed method allows reduction of the number of frames by the factor of 1/6. Also, it can represent the 3D depth through visual perceptions. Thus, real time volume rendering can be done with the proposed method.

  13. Eye formation in rotating convection

    Science.gov (United States)

    Oruba, L.; Davidson, P. A.; Dormy, E.

    2017-02-01

    We consider rotating convection in a shallow, cylindrical domain. We examine the conditions under which the resulting vortex develops an eye at its core; that is, a region where the poloidal flow reverses and the angular momentum is low. For simplicity, we restrict ourselves to steady, axisymmetric flows in a Boussinesq fluid. Our numerical experiments show that, in such systems, an eye forms as a passive response to the development of a so-called eyewall, a conical annulus of intense, negative azimuthal vorticity that can form near the axis and separates the eye from the primary vortex. We also observe that the vorticity in the eyewall comes from the lower boundary layer, and relies on the fact the poloidal flow strips negative vorticity out of the boundary layer and carries it up into the fluid above as it turns upward near the axis. This process is effective only if the Reynolds number is sufficiently high for the advection of vorticity to dominate over diffusion. Finally we observe that, in the vicinity of the eye and the eyewall, the buoyancy and Coriolis forces are negligible, and so although these forces are crucial to driving and shaping the primary vortex, they play no direct role in eye formation in a Boussinesq fluid.

  14. Best practice eye care models

    Science.gov (United States)

    Qureshi, Babar M; Mansur, Rabiu; Al-Rajhi, Abdulaziz; Lansingh, Van; Eckert, Kristen; Hassan, Kunle; Ravilla, Thulasiraj; Muhit, Mohammad; Khanna, Rohit C; Ismat, Chaudhry

    2012-01-01

    Since the launching of Global Initiative, VISION 2020 “the Right to Sight” many innovative, practical and unique comprehensive eye care services provision models have evolved targeting the underserved populations in different parts of the World. At places the rapid assessment of the burden of eye diseases in confined areas or utilizing the key informants for identification of eye diseases in the communities are promoted for better planning and evidence based advocacy for getting / allocation of resources for eye care. Similarly for detection and management of diabetes related blindness, retinopathy of prematurity and avoidable blindness at primary level, the major obstacles are confronted in reaching to them in a cost effective manner and then management of the identified patients accordingly. In this regard, the concept of tele-ophthalmology model sounds to be the best solution. Whereas other models on comprehensive eye care services provision have been emphasizing on surgical output through innovative scales of economy that generate income for the program and ensure its sustainability, while guaranteeing treatment of the poorest of the poor. PMID:22944741

  15. THE EFFECT OF GAZE ANGLE ON THE EVALUATIONS OF SAR AND TEMPERATURE RISE IN HUMAN EYE UNDER PLANE-WAVE EXPOSURES FROM 0.9 TO 10 GHZ.

    Science.gov (United States)

    Diao, Yinliang; Leung, Sai-Wing; Chan, Kwok Hung; Sun, Weinong; Siu, Yun-Ming; Kong, Richard

    2016-12-01

    This article investigates the effect of gaze angle on the specific absorption rate (SAR) and temperature rise in human eye under electromagnetic exposures from 0.9 to 10 GHz. Eye models in different gaze angles are developed based on biometric data. The spatial-average SARs in eyes are investigated using the finite-difference time-domain method, and the corresponding maximum temperature rises in lens are calculated by the finite-difference method. It is found that the changes in the gaze angle produce a maximum variation of 35, 12 and 20 % in the eye-averaged SAR, peak 10 g average SAR and temperature rise, respectively. Results also reveal that the eye-averaged SAR is more sensitive to the changes in the gaze angle than peak 10 g average SAR, especially at higher frequencies. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Physiology and pathology of eye-head coordination.

    Science.gov (United States)

    Proudlock, Frank Antony; Gottlob, Irene

    2007-09-01

    Human head movement control can be considered as part of the oculomotor system since the control of gaze involves coordination of the eyes and head. Humans show a remarkable degree of flexibility in eye-head coordination strategies, nonetheless an individual will often demonstrate stereotypical patterns of eye-head behaviour for a given visual task. This review examines eye-head coordination in laboratory-based visual tasks, such as saccadic gaze shifts and combined eye-head pursuit, and in common tasks in daily life, such as reading. The effect of the aging process on eye-head coordination is then reviewed from infancy through to senescence. Consideration is also given to how pathology can affect eye-head coordination from the lowest through to the highest levels of oculomotor control, comparing conditions as diverse as eye movement restrictions and schizophrenia. Given the adaptability of the eye-head system we postulate that this flexible system is under the control of the frontal cortical regions, which assist in planning, coordinating and executing behaviour. We provide evidence for this based on changes in eye-head coordination dependant on the context and expectation of presented visual stimuli, as well as from changes in eye-head coordination caused by frontal lobe dysfunction.

  17. Expression profile of the matricellular protein osteopontin in primary open-angle glaucoma and the normal human eye.

    Science.gov (United States)

    Chowdhury, Uttio Roy; Jea, Seung-Youn; Oh, Dong-Jin; Rhee, Douglas J; Fautsch, Michael P

    2011-08-16

    PURPOSE. To characterize the role of osteopontin (OPN) in primary open-angle glaucoma (POAG) and normal eyes. METHODS. OPN quantification was performed by enzyme-linked immunosorbent assay in aqueous humor (AH) obtained from human donor eyes (POAG and normal) and surgical samples (POAG and elective cataract removal). OPN expression and localization in whole eye tissue sections and primary normal human trabecular meshwork (NTM) cells were studied by Western blot and immunohistochemistry. Latanoprost-free acid (LFA)-treated NTM cells were analyzed for OPN gene and protein expression. Intraocular pressure was measured by tonometry, and central corneal thickness was measured by optical coherence tomography in young OPN(-/-) and wild-type mice. RESULTS. OPN levels were significantly reduced in donor POAG AH compared with normal AH (0.54 ± 0.18 ng/μg [n = 8] vs. 0.77 ± 0.23 ng/μg [n = 9]; P = 0.039). A similar trend was observed in surgical AH (1.05 ± 0.31 ng/μg [n = 20] vs. 1.43 ± 0.88 ng/μg [n = 20]; P = 0.083). OPN was present in the trabecular meshwork, corneal epithelium and endothelium, iris, ciliary body, retina, vitreous humor, and optic nerve. LFA increased OPN gene expression, but minimal change in OPN protein expression was observed. No difference in intraocular pressure (17.5 ± 2.0 mm Hg [n = 56] vs. 17.3 ± 1.9 mm Hg [n = 68]) but thinner central corneal thickness (91.7 ± 3.6 μm [n = 50] vs. 99.2 ± 5.5 μm [n = 70]) was noted between OPN(-/-) and wild-type mice. CONCLUSIONS. OPN is widely distributed in the human eye and was found in lower concentrations in POAG AH. Reduction of OPN in young mice does not affect IOP.

  18. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    Science.gov (United States)

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test.

  19. Is there any difference in the photobiological properties of melanins isolated from human blue and brown eyes?

    Science.gov (United States)

    Menon, I A; Basu, P K; Persad, S; Avaria, M; Felix, C C; Kalyanaraman, B

    1987-01-01

    Investigations were carried out to determine whether the melanin present in the blue and brown eyes were eumelanin, the melanin present in black hair and dark skin, or pheomelanin, the melanin present in red hair and the skin of people with red hair. Our results showed that UV-visible irradiation of blue or brown eye melanin did not produce any superoxide. Irradiation of 51Cr-labelled Ehrlich ascites carcinoma cells in the presence of blue or brown eye melanin did not produce significant cell lysis. The electron spin resonance (ESR) signals of blue and brown eye melanins were very similar to those of eumelanin. Comparison of these findings with our previous results indicated that the blue and brown eye melanins are essentially eumelanin. The ESR signals further suggested that in the case of both blue and brown eye melanins the iris, ciliary body, choroid, and retinal pigment epithelium did not differ. PMID:2820463

  20. Yarbus, Eye Movements, and Vision

    Directory of Open Access Journals (Sweden)

    Benjamin W Tatler

    2010-04-01

    Full Text Available The impact of Yarbus's research on eye movements was enormous following the translation of his book Eye Movements and Vision into English in 1967. In stark contrast, the published material in English concerning his life is scant. We provide a brief biography of Yarbus and assess his impact on contemporary approaches to research on eye movements. While early interest in his work focused on his study of stabilised retinal images, more recently this has been replaced with interest in his work on the cognitive influences on scanning patterns. We extended his experiment on the effect of instructions on viewing a picture using a portrait of Yarbus rather than a painting. The results obtained broadly supported those found by Yarbus.

  1. Phantom pain after eye amputation

    DEFF Research Database (Denmark)

    Rasmussen, Marie L R; Prause, Jan U; Toft, Peter B

    2011-01-01

    Purpose: To characterize the quality of phantom pain, its intensity and frequency following eye amputation. Possible triggers and relievers of phantom pain are investigated. Methods: The hospital database was searched using surgery codes for patients who received ocular evisceration, enucleation,...... appears to be similar to the phantom pain suffered by limb amputees. Patients should be informed about this potential complication before surgery.......Purpose: To characterize the quality of phantom pain, its intensity and frequency following eye amputation. Possible triggers and relievers of phantom pain are investigated. Methods: The hospital database was searched using surgery codes for patients who received ocular evisceration, enucleation...... was conducted by a trained interviewer. Results: Of the 173 patients in the study, 39 experienced phantom pain. The median age of patients who had experienced phantom pain was 45 years (range: 19–88). Follow-up time from eye amputation to participation in the investigation was 4 years (range: 2–46). Phantom...

  2. Structural neural substrates of reading the mind in the eyes

    Directory of Open Access Journals (Sweden)

    Wataru eSato

    2016-04-01

    Full Text Available The ability to read the minds of others in their eyes plays an important role in human adaptation to social environments. Behavioral studies have resulted in the development of a test to measure this ability (Reading the Mind in the Eyes Test, revised version; Eyes Test, and have demonstrated that this ability is consistent over time. Although functional neuroimaging studies revealed brain activation while performing the Eyes Test, the structural neural substrates supporting consistent performance on the Eyes Test remain unclear. In this study we assessed the Eyes Test and analyzed structural magnetic resonance images using voxel-based morphometry in healthy participants. Test performance was positively associated with the gray matter volumes of the dorsomedial prefrontal cortex, inferior parietal lobule (temporoparietal junction, and precuneus in the left hemisphere. These results suggest that the fronto-temporoparietal network structures support the consistent ability to read the mind in the eyes.

  3. Comparative spectral analysis between the functionality of the human eye and of the optical part of a digital camera

    Science.gov (United States)

    Toadere, Florin

    2015-02-01

    A software that comparatively analysis the spectral functionality of the optical part of the human eye and of the optical image acquisition system of the digital camera, is presented. Comparisons are done using demonstrative images which present the spectral color transformations of an image that is considered the test object. To perform the simulations are presented the spectral models and are computed their effects on the colors of the spectral image, during the propagation of the D48 sun light through the eye and the optics of the digital camera. The simulations are made using a spectral image processing algorithm which converts the spectral image into XYZ color space, CIE CAM02 color appearance model and then into RGB color space.

  4. Attention to irrelevant contexts decreases as training increases: Evidence from eye-fixations in a human predictive learning task.

    Science.gov (United States)

    Aristizabal, José A; Ramos-Álvarez, Manuel M; Callejas-Aguilera, José E; Rosas, Juan M

    2016-03-01

    Participants were trained in a human predictive learning task in which they had to predict whether the ingestion of a given food (cue) by the imaginary customer of an imaginary restaurant (context) was followed by gastric malaise (outcome). One food was always followed by gastric malaise in one of the contexts, while other foods were not followed by gastric malaise in the same, or in an alternative context. Predictive responses and eye-fixations were recorded throughout the 48 training trials with each cue involved in the task. In agreement with the predictions of the Attentional Theory of Context Processing, attention to the contexts measured through eye-fixations decreased while attention to the cues increased as training progressed. The results of this study give support to the idea that contexts are actively processed at the beginning of acquisition, and that this processing decreases as training increases.

  5. The sightless eyes of reason

    DEFF Research Database (Denmark)

    Andrade-Molina, Melissa; Valero, Paola

    2015-01-01

    There is a gap between the aims of school geometry in terms of the teaching of spatial abilities to young children, and the dominance of a school geometry rooted in Euclid’s axioms and abstractions. Such gap is not to be explained in terms of a “misimplementation” of the curricular intentions. Ra...... geometry curriculum. We argue that school geometry fabricates the scientific minds of the future by training students to see not with the eyes of their bodies, but with the eyes of reason and logic...

  6. Eye Redness Image Processing Techniques

    Science.gov (United States)

    Adnan, M. R. H. Mohd; Zain, Azlan Mohd; Haron, Habibollah; Alwee, Razana; Zulfaezal Che Azemin, Mohd; Osman Ibrahim, Ashraf

    2017-09-01

    The use of photographs for the assessment of ocular conditions has been suggested to further standardize clinical procedures. The selection of the photographs to be used as scale reference images was subjective. Numerous methods have been proposed to assign eye redness scores by computational methods. Image analysis techniques have been investigated over the last 20 years in an attempt to forgo subjective grading scales. Image segmentation is one of the most important and challenging problems in image processing. This paper briefly outlines the comprehensive of image processing and the implementation of image segmentation in eye redness.

  7. Trehalose-Based Eye Drops Preserve Viability and Functionality of Cultured Human Corneal Epithelial Cells during Desiccation

    Directory of Open Access Journals (Sweden)

    Aneta Hill-Bator

    2014-01-01

    Full Text Available This paper presents the evaluation of cytoprotective ability of trehalose-based eye drops in comparison with commercially available preparations during the experimental desiccation of cultured human corneal epithelial cells. Cultured human corneal epithelial cells (hCEC underwent incubation with 7 different, commercially available medicaments used commonly in dry eye syndrome treatment, followed by desiccation trial performed on air under the flow hood for 5, 15, 30, and 45 minutes. Cell viability was quantified by live/dead fluorescent assay, while the presence of apoptotic cells was estimated by immunofluorescent staining for active caspase 3 protein. The preservation of membrane functions was evaluated using neutral red staining, while the preservation of proper morphology and phenotype was determined by fluorescent staining for actin filaments, nuclei, and p63 protein. The trehalose-based eye drops showed the highest efficiency in prevention of cell death from desiccation; moreover, this preparation preserved the normal cellular morphology, functions of cell membrane, and proliferative activity more effectively than other tested medicaments.

  8. Optical study on the vision correction and supernormal vision based on the wave-front aberrations of human eye

    Institute of Scientific and Technical Information of China (English)

    MU GuoGuang; WANG ZhaoQi; LIU YongJi; QUAN Wei; WANG Yang; WANG Wei

    2007-01-01

    In this paper we present the recent research results in the field of vision correction and supernormal vision according to the actual measurements of the wave-front aberrations and the corneal surface topography, the clinical detection of the visual function and the laser corneal refractive surgery, and the optimization of the optical system. These include the features of the aberrations of human eye with different pupil sizes, different fields of view and temporal accommodation, the influence of the polychromatic illumination of the visible wavelength on the supernormal vision,and the effect of the existing laser corneal refractive surgery on the wave-front aberrations of the eye. It is shown that the wave-front aberration of human eye is of temporal variation and of synthesis with multi impact factors. To achieve supernormal vision, an optimum engineering data for the customized laser corneal surgery should be firstly acquired, which may involve the dynamic free-form optical surface. Although the myopia can be corrected by the laser in situ keratomileusis (LASlK) in a certain degree, it brings about negative effects under scotopic conditions.

  9. Optical study on the vision correction and supernormal vision based on the wave-front aberrations of human eye

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    In this paper we present the recent research results in the field of vision correction and supernormal vision according to the actual measurements of the wave-front aberrations and the corneal surface topography,the clinical detection of the visual function and the laser corneal refractive surgery,and the optimization of the optical system. These include the features of the aberrations of human eye with different pupil sizes,different fields of view and temporal accommodation,the influence of the polychromatic illumination of the visible wavelength on the supernormal vision,and the effect of the existing laser corneal refractive surgery on the wave-front ab-errations of the eye. It is shown that the wave-front aberration of human eye is of temporal variation and of synthesis with multi impact factors. To achieve super-normal vision,an optimum engineering data for the customized laser corneal sur-gery should be firstly acquired,which may involve the dynamic free-form optical surface. Although the myopia can be corrected by the laser in situ keratomileusis(LASIK) in a certain degree,it brings about negative effects under scotopic condi-tions.

  10. Eye mechanics and their implications for eye movement control

    NARCIS (Netherlands)

    Koene, Ansgar Roald

    2002-01-01

    The topic of this thesis is the investigation of the mechanical properties of the oculomotor system and the implications of these properties for eye movement control. The investigation was conducted by means of computer models and simulations. This allowed us to combine data from anatomy, physiology

  11. Holographic interferometry of intact and radially incised human eye-bank corneas.

    Science.gov (United States)

    Smolek, M K

    1994-05-01

    Many methods to measure corneal elasticity destroy the tissue and thereby produce erroneous results. Holographic interferometry, a highly precise nondestructive optical comparison technique, was used to evaluate corneal elasticity of intact eye-bank eyes. A double-pulse holographic interferometer operating at 632.8 nm was used to measure corneal deformation in 20 whole-globe eyes from donors 45 to 83 years of age for intraocular pressures from 16 mm Hg to 21 mm Hg. Stress was computed from LaPlace's law, and arc length strain was derived from z-axis distention of the central cornea. The stress-strain relationship in the normal physiological range of intraocular pressure was linear with a Young's elastic modulus of 1.03 gigapascals for the central cornea (r = 0.999). During interferometry of radial keratotomy of the cornea, interference fringe patterns developed in association with each incision as it was made. When four incisions were placed deep along each of the primary semimeridians, the fringe pattern developed as expected, based on current keratotomy models. When incisions were shallow (approximately 50% depth) and placed asymmetrically along the nasal, temporal, and superior semimeridians, the resulting surface strain was symmetrical about the central cornea, forming an annular pattern of interference fringes. These results indicate that when the cornea was stressed at physiological pressures as part of the intact whole globe, it was less elastic than excised corneal tissue tested by strip extensiometry. Radially incised corneas demonstrated strain patterns suggestive of inherent structural anisotropy with a possible inferior quadrant weakness.

  12. Eye-movements and ongoing task processing.

    Science.gov (United States)

    Burke, David T; Meleger, Alec; Schneider, Jeffrey C; Snyder, Jim; Dorvlo, Atsu S S; Al-Adawi, Samir

    2003-06-01

    This study tests the relation between eye-movements and thought processing. Subjects were given specific modality tasks (visual, gustatory, kinesthetic) and assessed on whether they responded with distinct eye-movements. Some subjects' eye-movements reflected ongoing thought processing. Instead of a universal pattern, as suggested by the neurolinguistic programming hypothesis, this study yielded subject-specific idiosyncratic eye-movements across all modalities. Included is a discussion of the neurolinguistic programming hypothesis regarding eye-movements and its implications for the eye-movement desensitization and reprocessing theory.

  13. Human eye cataract microstructure modeling and its effect on simulated retinal imaging

    Science.gov (United States)

    Fan, Wen-Shuang; Chang, Chung-Hao; Horng, Chi-Ting; Yao, Hsin-Yu; Sun, Han-Ying; Huang, Shu-Fang; Wang, Hsiang-Chen

    2017-02-01

    We designed a crystalline microstructure during cataract lesions and calculated the aberration value of the eye by using ray trace modeling to identify the corresponding spherical aberration, coma aberration, and trefoil aberration value under different pathological-change degrees. The mutual relationship between microstructure and aberration was then discussed using these values. Calculation results showed that with increased layer number of microstructure, the influence of aberration value on spherical aberration was the greatest. In addition, the influence of a relatively compact microstructure on spherical aberration and coma aberration was small, but that on trefoil aberration was great.

  14. Human regional cerebral blood flow during rapid-eye-movement sleep

    DEFF Research Database (Denmark)

    Madsen, P L; Holm, S; Vorstrup, S;

    1991-01-01

    Owing to the coupling between CBF and neuronal activity, regional CBF is a reflection of neural activity in different brain regions. In this study we measured regional CBF during polysomnographically well-defined rapid-eye-movement (REM) sleep by the use of single photon emission computerized...... tomography and the new tracer 99mTc-dl-hexamethylpropyleneamine. Eleven healthy volunteers aged between 22 and 27 years were studied. CBF was measured on separate nights during REM sleep and during EEG-verified wakefulness. On awakening from REM sleep, all subjects reported visual dreams. During REM sleep...

  15. Ocular surface area and human eye blink frequency during VDU work

    DEFF Research Database (Denmark)

    Nielsen, Pernille Kofoed; Søgaard, Karen; Skotte, Jørgen

    2008-01-01

    The purpose of this study was to investigate how the ocular surface area (OSA) and the eye blink frequency (BF) are affected by a high versus a low-monitor position during visual display unit (VDU) work with varying cognitive demands. In a balanced randomized (2 x 2) design ten healthy subjects....... The low BF during the active task was succeded by a burst with high BF after cessation of the active task, indicating a compensatory blinking process. This stresses that interchange of work tasks with different cognitive load is as important as the monitor position in the prevention of visual...

  16. The Dkk1 dose is critical for eye development.

    Science.gov (United States)

    Lieven, Oliver; Rüther, Ulrich

    2011-07-01

    During mammalian ocular development, several signaling pathways control the spatiotemporal highly defined realization of the three-dimensional eye architecture. Given the complexity of these inductive signals, the developing eye is a sensitive organ for several diseases. In this study, we investigated a Dkk1+/- haploinsufficiency during eye development, resulting in coloboma and anterior eye defects, two common developmental eye disorders. Dkk1 impacts eye development from a defined developmental time point on, and is critical for lens separation from the surface ectoderm via β-catenin mediated Pdgfrα and E-cadherin expression. Dkk1 does not impact the dorso ventral retina patterning in general but is critical for Shh dependent Pax2 extension into the midline region. The described results also indicate that the retinal Dkk1 dose is critical for important steps during eye development, such as optic fissure closure and cornea formation. Further analysis of the relationship between Dkk1 and Shh signaling revealed that Dkk1 and Shh coordinatively control anterior head formation and eye induction. During eye development itself, retinal Dkk1 activation is depending on cilia mediated Gli3 regulation. Therefore, our data essentially improve the knowledge of coloboma and anterior eye defects, which are common human eye developmental defects.

  17. Optical eye simulator for laser dazzle events.

    Science.gov (United States)

    Coelho, João M P; Freitas, José; Williamson, Craig A

    2016-03-20

    An optical simulator of the human eye and its application to laser dazzle events are presented. The simulator combines optical design software (ZEMAX) with a scientific programming language (MATLAB) and allows the user to implement and analyze a dazzle scenario using practical, real-world parameters. Contrary to conventional analytical glare analysis, this work uses ray tracing and the scattering model and parameters for each optical element of the eye. The theoretical background of each such element is presented in relation to the model. The overall simulator's calibration, validation, and performance analysis are achieved by comparison with a simpler model based uponCIE disability glare data. Results demonstrate that this kind of advanced optical eye simulation can be used to represent laser dazzle and has the potential to extend the range of applicability of analytical models.

  18. NotifEye

    DEFF Research Database (Denmark)

    Lucero, Andrés; Vetek, Akos

    2014-01-01

    In this paper we explore the use of interactive eyewear in public. We introduce NotifEye, an application that allows a person to receive social network notifications on interactive glasses while walking on a busy street. The prototype uses a minimalistic user interface (UI) for interactive glasses...

  19. Deformable Models for Eye Tracking

    DEFF Research Database (Denmark)

    Vester-Christensen, Martin; Leimberg, Denis; Ersbøll, Bjarne Kjær;

    2005-01-01

    A deformable template method for eye tracking on full face images is presented. The strengths of the method are that it is fast and retains accuracy independently of the resolution. We compare the me\\$\\backslash\\$-thod with a state of the art active contour approach, showing that the heuristic...

  20. Preventing eye injuries in quarries

    Directory of Open Access Journals (Sweden)

    Richard Wormald

    2016-01-01

    Full Text Available Eye injuries often occur in the workplace in low and middle-income countries, particularly in the construction, agricultural, mining, and manufacturing industries. Even if there are safety regulations in these industries, their enforcement is often unsatisfactory, and owners are not required to provide safety equipment.

  1. Silence, an Eye of Knowledge

    Directory of Open Access Journals (Sweden)

    Mehdi Aghamohammadi

    2017-04-01

    Full Text Available One of the conspicuous features of the twentieth-century West was silence. This idea could be supported by examining reflections of Ludwig Wittgenstein, Fritz Mauthner, John Cage, Samuel Beckett, Ihab Hassan, Franz Kafka, Wassily Kandinsky, Jean-Paul Sartre, Virginia Woolf, Wolfgang Iser, Jacques Derrida, and Pierre Macherey. To me, silence is not a mere theory, but rather a phenomenon from which we can get practical benefits. I believe silence is an eye, eye of knowledge. We can broaden our knowledge of the world through silence. To convey the idea that silence is an eye, I have concocted the word slence, where  has replaced the letter i and stands for the eye. This means knowledge can enable us to see, thereby acquiring knowledge of, what used to be invisible, and accordingly unknowable. In other words, through silence, we can achieve a certain type of literacy. I substantiate this claim by exploring the Horus myth, Ojo de Dios, John Cage’s 4' 33", the nature of Expressionist paintings, Hinduism, thoughts of Hermes Trismegistus and Ibn al-Arabi, and practices of Mohammad, the prophet of Islam.

  2. Autostereoscopic display with eye tracking

    Science.gov (United States)

    Tomono, Takao; Hoon, Kyung; Ha, Yong Soo; Kim, Sung-Sik; Son, Jung-Young

    2002-05-01

    Auto-stereoscopic 21-inch display with eye tracking having wide viewing zone and bright image was fabricated. The image of display is projected to retinal through several optical components. We calculated optical system for wider viewing zone by using Inverse-Ray Trace Method. The viewing zone of first model is 155mm (theoretical value: 161mm). We could widen viewing zone by controlling paraxial radius of curvature of spherical mirror, the distance between lenses and so on. The viewing zone of second model is 208mm. We used two spherical mirrors to obtain twice brightness. We applied eye-tracking system to the display system. Eye recognition is based on neural network card based on ZICS technology. We fabricated Auto-stereoscopic 21-inch display with eye tracking. We measured viewing zone based on illumination area. The viewing zone was 206mm, which was close to theoretical value. We could get twice brightness also. We could see 3D image according to position without headgear.

  3. Improving eye care in Rwanda.

    Science.gov (United States)

    Binagwaho, Agnes; Scott, Kirstin; Rosewall, Thomas; Mackenzie, Graeme; Rehnborg, Gweneth; Hannema, Sjoerd; Presente, Max; Noe, Piet; Mathenge, Wanjiku; Nkurikiye, John; Habiyaremye, Francois; Dushime, Theophile

    2015-06-01

    Visual impairment affects nearly 285 million people worldwide. Although there has been much progress in combating the burden of visual impairment through initiatives such as VISION 2020, barriers to progress, especially in African countries, remain high. The Rwandan Ministry of Health has formed partnerships with several nongovernmental organizations and has worked to integrate their efforts to prevent and treat visual impairment, including presbyopia. Rwanda, an eastern African country of approximately 11 million people. The Rwandan Ministry of Health developed a single national plan that allows key partners in vision care to coordinate more effectively in measuring eye disease, developing eye care infrastructure, building capacity, controlling disease, and delivering and evaluating services. Collaboration between stakeholders under a single national plan has ensured that resources and efforts are complementary, optimizing the ability to provide eye care. Improved access to primary eye care and insurance coverage has increased demand for services at secondary and tertiary levels. A comprehensive strategy that includes prevention as well as a supply chain for glasses and lenses is needed.

  4. Building the eye care team

    Directory of Open Access Journals (Sweden)

    Thulasiraj Ravilla

    2014-07-01

    Full Text Available Eye care services are people intensive. They require the right people (competence, in the right numbers (capacity, in the right mix (team with the right resources and processes (enabling conditions to ensure effective and sustainable delivery of patient care.

  5. Anticipatory Eye Movements in Congkak

    Directory of Open Access Journals (Sweden)

    Sheryl Chong

    2011-05-01

    Full Text Available Congkak is a traditional Malaysian board game involving two players taking turns to pick up marbles from a series of holes on the board. We used this game as a model to explore the role of anticipatory eye movements during natural actions (in this case serially picking up/putting marbles as novices learnt the game. Prior work on eye and hand movements in natural behaviour shows that much of the demand on the visual system is computed at the moment it is needed and doesn't depend on information acquired from previous fixations. Vision is driven by the task demands. However, anticipatory fixations to upcoming targets of manipulation have recently been shown to confer spatial accuracy and influence the eye-hand latency. We find that experience with the game also influences the deployment of these anticipatory “look-ahead” fixations, and that their influence on eye-hand latency varies with experience. Results suggest that as our experience in Congkak grows, so does our knowledge of the space relationships necessary for task success.

  6. RESEARCH OF LINEAR AND NONLINEAR PROCESSES AT FEMTOSECOND LASER RADIATION PROPAGATION IN THE MEDIUM SIMULATING THE HUMAN EYE VITREOUS

    Directory of Open Access Journals (Sweden)

    P. Y. Rogov

    2015-09-01

    Full Text Available The paper deals with mathematical model of linear and nonlinear processes occurring at the propagation of femtosecond laser pulses in the vitreous of the human eye. Methods of computing modeling are applied for the nonlinear spectral equation solution describing the dynamics of a two-dimensional TE-polarized radiation in a homogeneous isotropic medium with cubic fast-response nonlinearity without the usage of slowly varying envelope approximation. Environments close to the optical media parameters of the eye were used for the simulation. The model of femtosecond radiation propagation takes into account the process dynamics for dispersion broadening of pulses in time and the occurence of the self-focusing near the retina when passing through the vitreous body of the eye. Dependence between the pulse duration on the retina has been revealed and the duration of the input pulse and the values of power density at which there is self-focusing have been found. It is shown that the main mechanism of radiation damage with the use of titanium-sapphire laser is photoionization. The results coincide with those obtained by the other scientists, and are usable for creation Russian laser safety standards for femtosecond laser systems.

  7. The modelling of the influence of a corneal geometry on the pupil image of the human eye

    Science.gov (United States)

    Szczesna, D. H.; Kasprzak, H. T.

    2006-07-01

    In normal conditions, a pupil of the eye is observed through the optical system of the cornea. The cornea is the anterior surface of the eye and is the major refractive element of the human eye. The influence of the corneal shape should not be neglected in measurements of the pupil size. The purpose of this study was to estimate the influence of the corneal geometry, the diameter of the pupil and its position in the anterior chamber on the magnification and position of the image of the pupil. The numerical calculations presented in the paper assume infinitely thin cornea, and the corneal topography was approximated by the elongated ellipsoid. The ray tracing procedure was used in our numerical modelling. The magnification of the pupil image amounted to about 10% and increases with decrease of radius of curvature and eccentricity of the corneal profile and decreases for the largest pupil. The results show also that the pupil image is placed nearer the corneal apex than the real pupil. The image of the pupil is always blurred, which limits the sharp observation of the pupil.

  8. Design and analysis of an adaptive lens that mimics the performance of the crystalline lens in the human eye

    Science.gov (United States)

    Santiago-Alvarado, Agustin; Cruz-Félix, Angel S.; Iturbide-Jiménez, F.; Martínez-López, M.; Ramírez-Como, M.; Armengol-Cruz, V.; Vásquez-Báez, I.

    2014-09-01

    Tunable lenses are optical systems that have attracted much attention due to their potential applications in such areas like ophthalmology, machine vision, microscopy and laser processing. In recent years we have been working in the analysis and performance of a liquid-filled variable focal length lens, this is a lens that can modify its focal length by changing the amount of water within it. Nowadays we extend our study to a particular adaptive lens known as solid elastic lens (SEL) that it is formed by an elastic main body made of Polydimethylsiloxane (PDMS Sylgard 184). In this work, we present the design, simulation and analysis of an adaptive solid elastic lens that in principle imitates the accommodation process of the crystalline lens in the human eye. For this work, we have adopted the parameters of the schematic eye model developed in 1985 by Navarro et al.; this model represents the anatomy of the eye as close as possible to reality by predicting an acceptable and accurate quantity of spherical and chromatic aberrations without any shape fitting. An opto-mechanical analysis of the accommodation process of the adaptive lens is presented, by simulating a certain amount of radial force applied onto the SEL using the finite element method with the commercial software SolidWorks®. We also present ray-trace diagrams of the simulated compression process of the adaptive lens using the commercial software OSLO®.

  9. Setting targets for human resources for eye health in sub-Saharan Africa: what evidence should be used?

    Science.gov (United States)

    Courtright, Paul; Mathenge, Wanjiku; Kello, Amir Bedri; Cook, Colin; Kalua, Khumbo; Lewallen, Susan

    2016-03-16

    With a global target set at reducing vision loss by 25% by the year 2019, sub-Saharan Africa with an estimated 4.8 million blind persons will require human resources for eye health (HReH) that need to be available, appropriately skilled, supported, and productive. Targets for HReH are useful for planning, monitoring, and resource mobilization, but they need to be updated and informed by evidence of effectiveness and efficiency. Supporting evidence should take into consideration (1) ever-changing disease-specific issues including the epidemiology, the complexity of diagnosis and treatment, and the technology needed for diagnosis and treatment of each condition; (2) the changing demands for vision-related services of an increasingly urbanized population; and (3) interconnected health system issues that affect productivity and quality. The existing targets for HReH and some of the existing strategies such as task shifting of cataract surgery and trichiasis surgery, as well as the scope of eye care interventions for primary eye care workers, will need to be re-evaluated and re-defined against such evidence or supported by new evidence.

  10. Did Language Evolve Like the Vertebrate Eye?

    Science.gov (United States)

    Botha, Rudolf P.

    2002-01-01

    Offers a critical appraisal of the way in which the idea that human language or some of its features evolved like the vertebrate eye by natural selection is articulated in Pinker and Bloom's (1990) selectionist account of language evolution. Argues that this account is less than insightful because it fails to draw some of the conceptual…

  11. Rotational symmetric HMD with eye-tracking capability

    Science.gov (United States)

    Liu, Fangfang; Cheng, Dewen; Wang, Qiwei; Wang, Yongtian

    2016-10-01

    As an important auxiliary function of head-mounted displays (HMDs), eye tracking has an important role in the field of intelligent human-machine interaction. In this paper, an eye-tracking HMD system (ET-HMD) is designed based on the rotational symmetric system. The tracking principle in this paper is based on pupil-corneal reflection. The ET-HMD system comprises three optical paths for virtual display, infrared illumination, and eye tracking. The display optics is shared by three optical paths and consists of four spherical lenses. For the eye-tracking path, an extra imaging lens is added to match the image sensor and achieve eye tracking. The display optics provides users a 40° diagonal FOV with a ״ 0.61 OLED, the 19 mm eye clearance, and 10 mm exit pupil diameter. The eye-tracking path can capture 15 mm × 15 mm of the users' eyes. The average MTF is above 0.1 at 26 lp/mm for the display path, and exceeds 0.2 at 46 lp/mm for the eye-tracking path. Eye illumination is simulated using LightTools with an eye model and an 850 nm near-infrared LED (NIR-LED). The results of the simulation show that the illumination of the NIR-LED can cover the area of the eye model with the display optics that is sufficient for eye tracking. The integrated optical system HMDs with eye-tracking feature can help improve the HMD experience of users.

  12. Rheumatoid Arthritis: Can It Affect the Eyes?

    Science.gov (United States)

    ... arthritis: Can it affect the eyes? Can rheumatoid arthritis affect the eyes? Answers from April Chang-Miller, M.D. Rheumatoid arthritis is a chronic inflammatory disease that primarily affects ...

  13. Eye Care: MedlinePlus Health Topic

    Science.gov (United States)

    ... of you for 20 seconds. Eye Tests and Exams Everyone needs to have their eyesight tested to ... an eye examination before entering nursing homes. Article: Caffeine metabolites not caffeine protect against riboflavin photosensitized oxidative ...

  14. Transpalpebral eye enucleation in the standing horse

    DEFF Research Database (Denmark)

    Christophersen, Mogens Teken

    Transpalpebral eye enucleation in the standing horse. The Nordic Equine Veterinary Conference, Proceedings, Copenhagen. Denmark. Nov. 2011.......Transpalpebral eye enucleation in the standing horse. The Nordic Equine Veterinary Conference, Proceedings, Copenhagen. Denmark. Nov. 2011....

  15. Genetic defects of GDF6 in the zebrafish out of sight mutant and in human eye developmental anomalies

    NARCIS (Netherlands)

    Hollander, A.I. den; Biyanwila, J.; Kovach, P.; Bardakjian, T.; Traboulsi, E.I.; Ragge, N.K.; Schneider, A.; Malicki, J.

    2010-01-01

    BACKGROUND: The size of the vertebrate eye and the retina is likely to be controlled at several stages of embryogenesis by mechanisms that affect cell cycle length as well as cell survival. A mutation in the zebrafish out of sight (out) locus results in a particularly severe reduction of eye size.

  16. Genetic defects of GDF6 in the zebrafish out of sight mutant and in human eye developmental anomalies

    NARCIS (Netherlands)

    Hollander, A.I. den; Biyanwila, J.; Kovach, P.; Bardakjian, T.; Traboulsi, E.I.; Ragge, N.K.; Schneider, A.; Malicki, J.

    2010-01-01

    BACKGROUND: The size of the vertebrate eye and the retina is likely to be controlled at several stages of embryogenesis by mechanisms that affect cell cycle length as well as cell survival. A mutation in the zebrafish out of sight (out) locus results in a particularly severe reduction of eye size. T

  17. Transcriptome analysis of Nautilus and pygmy squid developing eye provides insights in lens and eye evolution.

    Science.gov (United States)

    Sousounis, Konstantinos; Ogura, Atsushi; Tsonis, Panagiotis A

    2013-01-01

    Coleoid cephalopods like squids have a camera-type eye similar to vertebrates. On the other hand, Nautilus (Nautiloids) has a pinhole eye that lacks lens and cornea. Since pygmy squid and Nautilus are closely related species they are excellent model organisms to study eye evolution. Having being able to collect Nautilus embryos, we employed next-generation RNA sequencing using Nautilus and pygmy squid developing eyes. Their transcriptomes were compared and analyzed. Enrichment analysis of Gene Ontology revealed that contigs related to nucleic acid binding were largely up-regulated in squid, while the ones related to metabolic processes and extracellular matrix-related genes were up-regulated in Nautilus. These differences are most likely correlated with the complexity of tissue organization in these species. Moreover, when the analysis focused on the eye-related contigs several interesting patterns emerged. First, contigs from both species related to eye tissue differentiation and morphogenesis as well as to cilia showed best hits with their Human counterparts, while contigs related to rabdomeric photoreceptors showed the best hit with their Drosophila counterparts. This bolsters the idea that eye morphogenesis genes have been generally conserved in evolution, and compliments other studies showing that genes involved in photoreceptor differentiation clearly follow the diversification of invertebrate (rabdomeric) and vertebrate (ciliated) photoreceptors. Interestingly some contigs showed as good a hit with Drosophila and Human homologues in Nautilus and squid samples. One of them, capt/CAP1, is known to be preferentially expressed in Drosophila developing eye and in vertebrate lens. Importantly our analysis also provided evidence of gene duplication and diversification of their function in both species. One of these genes is the Neurofibromatosis 1 (NF1/Nf1), which in mice has been implicated in lens formation, suggesting a hitherto unsuspected role in the evolution

  18. Prevention of sports-related eye injury.

    Science.gov (United States)

    Stock, J G; Cornell, F M

    1991-08-01

    Sports-related eye injury is an important cause of vision loss. Many eye injuries can be prevented through the supervision of play, the enforcement of game rules and the use of eye protective devices. State-of-the-art eye protective devices incorporate highly impact-resistant optical material, usually polycarbonate lenses, in a sturdy frame. Protective devices are available for use in racquet sports, baseball, basketball, football, ice hockey and other sports.

  19. Infant Eyes: A Window on Cognitive Development

    Science.gov (United States)

    Aslin, Richard N.

    2012-01-01

    Eye-trackers suitable for use with infants are now marketed by several commercial vendors. As eye-trackers become more prevalent in infancy research, there is the potential for users to be unaware of dangers lurking "under the hood" if they assume the eye-tracker introduces no errors in measuring infants' gaze. Moreover, the influx of voluminous…

  20. Trustworthy-looking face meets brown eyes.

    Directory of Open Access Journals (Sweden)

    Karel Kleisner

    Full Text Available We tested whether eye color influences perception of trustworthiness. Facial photographs of 40 female and 40 male students were rated for perceived trustworthiness. Eye color had a significant effect, the brown-eyed faces being perceived as more trustworthy than the blue-eyed ones. Geometric morphometrics, however, revealed significant correlations between eye color and face shape. Thus, face shape likewise had a significant effect on perceived trustworthiness but only for male faces, the effect for female faces not being significant. To determine whether perception of trustworthiness was being influenced primarily by eye color or by face shape, we recolored the eyes on the same male facial photos and repeated the test procedure. Eye color now had no effect on perceived trustworthiness. We concluded that although the brown-eyed faces were perceived as more trustworthy than the blue-eyed ones, it was not brown eye color per se that caused the stronger perception of trustworthiness but rather the facial features associated with brown eyes.

  1. Clinical light damage to the eye

    Energy Technology Data Exchange (ETDEWEB)

    Miller, D.

    1987-01-01

    This book contains four sections: The Nature of Light and of Light Damage to Biological Tissues; Light Damage to the Eye; Protecting the Eye from Light Damage; and Overview of Light Damage to the Eye. Some of the paper titles are: Ultraviolet-Absorbing Intraocular Lens Implants; Phototoxic Changes in the Retina; Light Damage to the Lens; and Radiation, Light, and Sight.

  2. Eye Gaze in Creative Sign Language

    Science.gov (United States)

    Kaneko, Michiko; Mesch, Johanna

    2013-01-01

    This article discusses the role of eye gaze in creative sign language. Because eye gaze conveys various types of linguistic and poetic information, it is an intrinsic part of sign language linguistics in general and of creative signing in particular. We discuss various functions of eye gaze in poetic signing and propose a classification of gaze…

  3. Trustworthy-looking face meets brown eyes.

    Science.gov (United States)

    Kleisner, Karel; Priplatova, Lenka; Frost, Peter; Flegr, Jaroslav

    2013-01-01

    We tested whether eye color influences perception of trustworthiness. Facial photographs of 40 female and 40 male students were rated for perceived trustworthiness. Eye color had a significant effect, the brown-eyed faces being perceived as more trustworthy than the blue-eyed ones. Geometric morphometrics, however, revealed significant correlations between eye color and face shape. Thus, face shape likewise had a significant effect on perceived trustworthiness but only for male faces, the effect for female faces not being significant. To determine whether perception of trustworthiness was being influenced primarily by eye color or by face shape, we recolored the eyes on the same male facial photos and repeated the test procedure. Eye color now had no effect on perceived trustworthiness. We concluded that although the brown-eyed faces were perceived as more trustworthy than the blue-eyed ones, it was not brown eye color per se that caused the stronger perception of trustworthiness but rather the facial features associated with brown eyes.

  4. Experiencing Light's Properties within Your Own Eye

    Science.gov (United States)

    Mauser, Michael

    2011-01-01

    Seeing the reflection, refraction, dispersion, absorption, polarization, and scattering or diffraction of light within your own eye makes these properties of light truly personal. There are practical aspects of these within the eye phenomena, such as eye tracking for computer interfaces. They also offer some intriguing diversions, for example,…

  5. Eye Gaze in Creative Sign Language

    Science.gov (United States)

    Kaneko, Michiko; Mesch, Johanna

    2013-01-01

    This article discusses the role of eye gaze in creative sign language. Because eye gaze conveys various types of linguistic and poetic information, it is an intrinsic part of sign language linguistics in general and of creative signing in particular. We discuss various functions of eye gaze in poetic signing and propose a classification of gaze…

  6. Advances in Eye Tracking in Infancy Research

    Science.gov (United States)

    Oakes, Lisa M.

    2012-01-01

    In 2004, McMurray and Aslin edited for "Infancy" a special section on eye tracking. The articles in that special issue revealed the enormous promise of automatic eye tracking with young infants and demonstrated that eye-tracking procedures can provide significant insight into the emergence of cognitive, social, and emotional processing in infancy.…

  7. Cytological examination of pink eye afflicted tubers

    Science.gov (United States)

    Pink eye is a tuber disorder of undetermined cause that can result in serious processing complications and storage losses throughout North America. Pink eye symptoms progress from ephemeral light pink colorations around bud-end eyes to water-soaked or dried and cracked “corky-patch” periderm. Late s...

  8. Advances in Eye Tracking in Infancy Research

    Science.gov (United States)

    Oakes, Lisa M.

    2012-01-01

    In 2004, McMurray and Aslin edited for "Infancy" a special section on eye tracking. The articles in that special issue revealed the enormous promise of automatic eye tracking with young infants and demonstrated that eye-tracking procedures can provide significant insight into the emergence of cognitive, social, and emotional processing in infancy.…

  9. The Tehran Eye Study: research design and eye examination protocol

    Directory of Open Access Journals (Sweden)

    Fotouhi Akbar

    2003-07-01

    Full Text Available Abstract Background Visual impairment has a profound impact on society. The majority of visually impaired people live in developing countries, and since most disorders leading to visual impairment are preventable or curable, their control is a priority in these countries. Considering the complicated epidemiology of visual impairment and the wide variety of factors involved, region specific intervention strategies are required for every community. Therefore, providing appropriate data is one of the first steps in these communities, as it is in Iran. The objectives of this study are to describe the prevalence and causes of visual impairment in the population of Tehran city; the prevalence of refractive errors, lens opacity, ocular hypertension, and color blindness in this population, and also the familial aggregation of refractive errors, lens opacity, ocular hypertension, and color blindness within the study sample. Methods Design Through a population-based, cross-sectional study, a total of 5300 Tehran citizens will be selected from 160 clusters using a stratified cluster random sampling strategy. The eligible people will be enumerated through a door-to-door household survey in the selected clusters and will be invited. All participants will be transferred to a clinic for measurements of uncorrected, best corrected and presenting visual acuity; manifest, subjective and cycloplegic refraction; color vision test; Goldmann applanation tonometry; examination of the external eye, anterior segment, media, and fundus; and an interview about demographic characteristics and history of eye diseases, eye trauma, diabetes mellitus, high blood pressure, and ophthalmologic cares. The study design and eye examination protocol are described. Conclusion We expect that findings from the TES will show the status of visual problems and their causes in the community. This study can highlight the people who should be targeted by visual impairment prevention programs.

  10. In the Eye of the Beholder-  A Survey of Models for Eyes and Gaze

    DEFF Research Database (Denmark)

    Witzner Hansen, Dan; Ji, Qiang

    2010-01-01

    Despite active research and significant progress in the last 30 years, eye detection and tracking remains challenging due to the individuality of eyes, occlusion, variability in scale, location, and light conditions. Data on eye location and details of eye movements have numerous applications...

  11. Relative size of the eye and orbit: an evolutionary and craniofacial constraint model for examining the etiology and disparate incidence of juvenile-onset myopia in humans.

    Science.gov (United States)

    Masters, Michael P

    2012-05-01

    The principal aim of this research is to provide a new model for investigating myopia in humans, and contribute to an understanding of the degree to which modern variation and evolutionary change in orbital and overall craniofacial morphology may help explain the common eye form association with this condition. Recent research into long and short-term evolution of the human orbit reveals a number of changes in this feature, and particularly since the Upper Paleolithic. These include a reduction in orbital depth, a decrease in anterior projection of the upper and lower orbital margins, and most notably, a reduction in orbital volume since the Holocene in East Asia. Reduced orbital volume in this geographic region could exacerbate an existing trend in recent hominin evolution toward larger eyes in smaller orbits, and may help explain the unusually high frequency of myopia in East Asian populations. The objective of the current study is to test a null hypothesis of no relationship between a ratio of orbit to eye volume and spherical equivalent refractive error (SER) in a sample of Chinese adults, and examine how relative size of the eye within the orbit relates to SER between the sexes and across the sample population. Analysis of the orbit, eye, and SER reveals a strong relationship between relative size of the eye within the orbit and the severity of myopic refractive error. An orbit/eye ratio of 3 for females and 3.5 for males (or an eye that occupies approximately 34% and 29% of the orbit, respectively), designates a clear threshold at which myopia develops, and becomes progressively worse as the eye continues to occupy a greater proportion of the orbital cavity. These results indicate that relative size of the eye within the orbit is an important factor in the development of myopia, and suggests that individuals with large eyes in small orbits lack space for adequate development of ocular tissues, leading to compression and distortion of the lithesome globe

  12. Quantum dots trace lymphatic drainage from the mouse eye

    Energy Technology Data Exchange (ETDEWEB)

    Tam, Alex L C; Gupta, Neeru; Zhang Zhexue; Yuecel, Yeni H, E-mail: yucely@smh.ca [Department of Ophthalmology and Vision Sciences, University of Toronto, M5T 2S8 (Canada)

    2011-10-21

    Glaucoma is a leading cause of blindness in the world, often associated with elevated eye pressure. Currently, all glaucoma treatments aim to lower eye pressure by improving fluid exit from the eye. We recently reported the presence of lymphatics in the human eye. The lymphatic circulation is known to drain fluid from organ tissues and, as such, lymphatics may also play a role in draining fluid from the eye. We investigated whether lymphatic drainage from the eye is present in mice by visualizing the trajectory of quantum dots once injected into the eye. Whole-body hyperspectral fluorescence imaging was performed in 17 live mice. In vivo imaging was conducted prior to injection, and 5, 20, 40 and 70 min, and 2, 6 and 24 h after injection. A quantum dot signal was observed in the left neck region at 6 h after tracer injection into the eye. Examination of immunofluorescence-labelled sections using confocal microscopy showed the presence of a quantum dot signal in the left submandibular lymph node. This is the first direct evidence of lymphatic drainage from the mouse eye. The use of quantum dots to image this lymphatic pathway in vivo is a novel tool to stimulate new treatments to reduce eye pressure and prevent blindness from glaucoma.

  13. Eye dominance in the small-eared bushbaby, Otolemur garnettii.

    Science.gov (United States)

    Rogers, L J; Ward, J P; Stafford, D

    1994-02-01

    Eye-preference has been measured in the small-eared bushbaby, Otolemur garnettii, using two testing conditions, one requiring the subject to look through a grid and the other involving trained looking through a small hole. Monocular eye use was scored for viewing a variety of stimuli. The six subjects (four adult females and two babies) tested using the grid showed left-eye dominance for viewing the tester. Five subjects were tested for viewing food and all were similarly left-eye preferent. That is, there was indication of an eye preference at the group level. The eye preference did not correlate with handedness for food reaching or holding in the same individuals. When three of the subjects were tested viewing the more arousing stimulus of their babies held in the tester's hand, the eye-preference changed; there was either no preference or a weaker left-eye preference. One subject was tested with novel stimuli (a toy monkey, the tester wearing a mask and a rubber snake) and showed a significant shift to a right-eye preference for viewing two of these stimuli. Increased arousal, or fear, was apparent in the latter tests. Comparison is made to eye dominance data for humans.

  14. About the Eye

    Medline Plus

    Full Text Available ... from NEI Grantees Spokesperson bios Statistics and Data ... to the NEI Website Manager . Department of Health and Human Services | The National Institutes of Health | USA.gov ...

  15. [Importance of asferic treatment of intraocular lenses in contrast sensitivity of the human eye].

    Science.gov (United States)

    Calţaru, Dana Cristina; Pop, Mihai

    2014-01-01

    Clinical study which follows the influence of asphericity of intraocular lenses on an important parameter of quality of vision in operated cataract patients - contrast sensibility. This is a pilot, prospective study with 131 eyes of 124 patients, which had cataract surgery by phacoemulsification between 2011-2012. All operations were done by the same surgeon. EXCLUSION CRITERIAS WERE: VA ( 0.7; postop refraction >0.75 D sf. or 0.75 D cyl, corneal diseases, optic nerv or retinal pathologies, atypical surgery, pupil diameter 3 mm. Postoperative control was done at six weeks and included : AV, optical correction, contrast sensibility testing, intraocular pressure, posterior pol exam. Contrast sensibility testing was done using a LCD device, in fotopic condition, CC-100 TOPCON. Contrast sensibility graphics were compared between spheric and aspheric lenses for Zeiss, AMO, Bausch&Lomb, Alcon. There were no statistically significant differences between aspherical lenses. Also, there were no differences for the same manufacturer between spherical and aspherical lenses.

  16. The eye and its diseases in Ancient Egypt

    DEFF Research Database (Denmark)

    Andersen, S. Ry

    1997-01-01

    Ophthalmology, History of ophthalmology, eyes in the Ancient Egypt, eye disease in Ancient Egypt, porotic hyperostosis, mummification......Ophthalmology, History of ophthalmology, eyes in the Ancient Egypt, eye disease in Ancient Egypt, porotic hyperostosis, mummification...

  17. Ten Ways to Prevent Eye Injuries at Work

    Science.gov (United States)

    ... Financial Assistance Information Vision Screening and Eye Exams Zika Virus and Vision Eye Problems Eye Problems Amblyopia ( ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision ...

  18. How Often Should I Have an Eye Exam?

    Science.gov (United States)

    ... Financial Assistance Information Vision Screening and Eye Exams Zika Virus and Vision Eye Problems Eye Problems Amblyopia ( ... Eye Health Report Reports and External Resources The Cost of Vision Problems The Future of Vision Vision ...

  19. Effectiveness of eye armor during blast loading.

    Science.gov (United States)

    Bailoor, Shantanu; Bhardwaj, Rajneesh; Nguyen, Thao D

    2015-11-01

    Ocular trauma is one of the most common types of combat injuries resulting from the interaction of military personnel with improvised explosive devices. Ocular blast injury mechanisms are complex, and trauma may occur through various injury mechanisms. However, primary blast injuries (PBI) are an important cause of ocular trauma that may go unnoticed and result in significant damage to internal ocular tissues and visual impairment. Further, the effectiveness of commonly employed eye armor, designed for ballistic and laser protection, in lessening the severity of adverse blast overpressures (BOP) is unknown. In this paper, we employed a three-dimensional (3D) fluid-structure interaction computational model for assessing effectiveness of the eye armor during blast loading on human eyes and validated results against free field blast measurements by Bentz and Grimm (2013). Numerical simulations show that the blast waves focused on the ocular region because of reflections from surrounding facial features and resulted in considerable increase in BOP. We evaluated the effectiveness of spectacles and goggles in mitigating the pressure loading using the computational model. Our results corroborate experimental measurements showing that the goggles were more effective than spectacles in mitigating BOP loading on the eye. Numerical results confirmed that the goggles significantly reduced blast wave penetration in the space between the armor and the eyes and provided larger clearance space for blast wave expansion after penetration than the spectacles. The spectacles as well as the goggles were more effective in reducing reflected BOP at higher charge mass because of the larger decrease in dynamic pressures after the impact. The goggles provided greater benefit of reducing the peak pressure than the spectacles for lower charge mass. However, the goggles resulted in moderate, sustained elevated pressure loading on the eye, that became 50-100% larger than the pressure loading

  20. Deploying the mental eye

    NARCIS (Netherlands)

    Koenderink, Jan; van Doorn, A.J.; Wagemans, Johan

    2015-01-01

    Three observers performed a task designed to quantify their "pictorial relief" in visual awareness for a photograph of a piece of sculpture. In separate sessions, they were instructed to assume one of two "mental viewpoints." The main objective was to investigate whether human observers have such

  1. Eye-catching Anaphora

    NARCIS (Netherlands)

    Koornneef, A.W.

    2008-01-01

    Anaphoric elements (e.g. reflexives such as himself, and pronouns such as she and his) are among the most frequently encountered words in virtually all human languages. The most important feature of these linguistic elements is that they cannot be fully interpreted in isolation, but depend on other

  2. Tromsø eye study

    DEFF Research Database (Denmark)

    Bertelsen, Geir; Peto, Tunde; Lindekleiv, Haakon;

    2013-01-01

    Purpose:  To determine the prevalence of visual impairment, retinopathy and macular oedema, and assess risk factors for retinopathy in persons with diabetes. Methods:  The present study included 514 participants with diabetes aged 46-87 years from the Tromsø Eye Study, a sub-study of the population......-based Tromsø Study in Norway. Visual acuity was measured using an auto-refractor. Retinal images from both eyes were graded for retinopathy and macular oedema. We collected data on risk factor exposure from self-report questionnaires, clinical examinations, laboratory measurements and case note reviews....... Regression models assessed the cross-sectional relationship between potential risk factors and diabetic retinopathy. Results:  The prevalence of visual impairment (corrected Snellen visual acuity...

  3. Management of thyroid eye disease

    Energy Technology Data Exchange (ETDEWEB)

    Bartalena, Luigi; Tanda, Maria Laura [Department of Endocrinology, University of Insubria, Ospedale di Circolo, Viale Borri, 57, 21100 Varese (Italy); Marcocci, Claudio; Pinchera, Aldo [Department of Endocrinology and Metabolism, University of Pisa, Pisa (Italy)

    2002-08-01

    Thyroid eye disease (TED) is the most frequent extrathyroidal manifestation of Graves' disease. In most instances it is mild and non-progressive, but in 3%-5% of cases it is severe. Non-severe TED requires only supportive measures, such as eye ointments, sunglasses and prisms. By contrast, severe TED requires aggressive treatment, either medical (high-dose glucocorticoids, orbital radiotherapy) or surgical (orbital decompression). The choice of treatment relies on the assessment of both TED severity and activity. Removal of controllable risk factors, especially cigarette smoking, is important to improve the course and the therapeutic outcome. A coordinated approach to the treatment of hyperthyroidism and TED is also required. Novel promising treatments, to be verified in large series of patients, include somatostatin analogues and cytokine antagonists. (orig.)

  4. Flavonoid intake and eye health.

    Science.gov (United States)

    Milbury, Paul E

    2012-01-01

    In the modern era of evidence-based scientific medicine, there is little recognition of centuries of shaman observational evidence. Yet it is extremely difficult to conduct long duration controlled studies of large populations. The controversy surrounding the issue of flavonoid bioactivity and alleged benefits for eye health is also plagued by natural product industry marketing efforts that rely on small, often poorly designed studies. Ample laboratory evidence exists from in vitro and in vivo studies that provide plausible mechanistic evidence for flavonoid interactions relevant to visual function. Lacking are large randomized double-blind placebo-controlled studies in older subjects who have early signs of vision impairment. These studies could link flavonoid intake and bioavailability to efficacy in prevention of age related vision disorders that develop over decades. Support for clinical trials remains to be found before a full "recommendation" can be made regarding the value of diets high in flavonoids for eye health.

  5. Interaction between the premotor processes of eye and hand movements: possible mechanism underlying eye-hand coordination.

    Science.gov (United States)

    Hiraoka, Koichi; Kurata, Naoatsu; Sakaguchi, Masato; Nonaka, Kengo; Matsumoto, Naoto

    2014-03-01

    Interaction between the execution process of eye movement and that of hand movement must be indispensable for eye-hand coordination. The present study investigated corticospinal excitability in the hand muscles during the premotor processes of eye and/or hand movement to elucidate interaction between these processes. Healthy humans performed a precued reaction task of eye and/or finger movement and motor-evoked potentials in the hand muscles were evoked in the reaction time. Leftward eye movement suppressed corticospinal excitability in the right abductor digiti minimi muscle only when little finger abduction was simultaneously executed. Corticospinal excitability in the first dorsal interosseous muscle was not suppressed by eye movement regardless of whether or not it was accompanied by finger movement. Suppression of corticospinal excitability in the hand muscles induced by eye movement in the premotor period depends on the direction of eye movement, the muscle tested, and the premotor process of the tested muscle. The suppression may reflect interaction between the motor process of eye movement and that of hand movement particularly active during eye-hand coordination tasks during which both processes proceed.

  6. Rabbits' eye globe sonographic biometry.

    Science.gov (United States)

    Toni, Maria Carolina; Meirelles, Adriana Érica Wilkes Burton; Gava, Fábio Nelson; Camacho, Aparecido Antônio; Laus, José Luiz; Canola, Júlio Carlos

    2010-11-01

    To measure intraocular structures in New Zealand White breed rabbits (Oryctolagus cuniculus Linnaeus, 1758) using A-mode and B-mode ultrasound with a 20 MHz transducer. In this study, the eyes of 15 rabbits were evaluated for determination of intraocular measurements using an ophthalmic ultrasound unit able to operate in both A and B-modes. The distances from the cornea to the anterior capsule of the lens (D1), from the anterior capsule of the lens to the posterior capsule of the lens (D2), from the posterior capsule of the lens to the retina (D3) and the complete length of the eye, which corresponds to the distance from the cornea to the retina (D4) were taken. The mean values obtained were 2.70 mm (± 0.22 mm) for D1, 7.32 mm (± 0.40 mm) for D2, 7.10 mm (± 0.45 mm) for D3 and 17.12 mm (± 0.41 mm) for D4. Statistical analyses using the Student's t-test showed that there were no differences between the eyes. The study was feasible without the need of pharmacological restraint and yielded normal mean values for ocular sonographic biometry in rabbits. © 2010 American College of Veterinary Ophthalmologists.

  7. Eye Formation in Rotating Convection

    CERN Document Server

    Oruba, L; Dormy, E

    2016-01-01

    We consider rotating convection in a shallow, cylindrical domain. We examine the conditions under which the resulting vortex develops an eye at its core; that is, a region where the poloidal flow reverses and the angular momentum is low. For simplicity, we restrict ourselves to steady, axisymmetric flows in a Boussinesq fluid. Our numerical experiments show that, in such systems, an eye forms as a passive response to the development of a so-called eyewall, a conical annulus of intense, negative azimuthal vorticity that can form near the axis and separates the eye from the primary vortex. We also observe that the vorticity in the eyewall comes from the lower boundary layer, and relies on the fact the poloidal flow strips negative vorticity out of the boundary layer and carries it up into the fluid above as it turns upward near the axis. This process is effective only if the Reynolds number is sufficiently high for the advection of vorticity to dominate over diffusion. Finally we observe that, in the vicinity o...

  8. Metabolic syndrome and eye diseases.

    Science.gov (United States)

    Poh, Stanley; Mohamed Abdul, Riswana Banu Binte; Lamoureux, Ecosse L; Wong, Tien Y; Sabanayagam, Charumathi

    2016-03-01

    Metabolic syndrome is becoming a worldwide medical and public health challenge as it has been seen increasing in prevalence over the years. Age-related eye diseases, the leading cause of blindness globally and visual impairment in developed countries, are also on the rise due to aging of the population. Many of the individual components of the metabolic syndrome have been shown to be associated with these eye diseases. However, the association of metabolic syndrome with eye diseases is not clear. In this review, we reviewed the evidence for associations between metabolic syndrome and certain ocular diseases in populations. We also reviewed the association of individual metabolic syndrome components with ocular diseases due to a paucity of research in this area. Besides, we also summarised the current understanding of etiological mechanisms of how metabolic syndrome or the individual components lead to these ocular diseases. With increasing evidence of such associations, it may be important to identify patients who are at risk of developing metabolic syndrome as prompt treatment and intervention may potentially decrease the risk of developing certain ocular diseases.

  9. Eye tracking disturbances in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Sharma Pradeep

    2000-01-01

    Full Text Available Purpose: To study the frequency of different types of eye tracking disturbances in schizophrenia. Materials and Methods: Smooth pursuit eye movements were studied by electro-oculography (EOG in 22 schizophrenic patients (ICD-10 criteria and 15 age and sex-matched controls. The studied parameters included average pursuit gain, number of saccades, the frequency of different types of saccades (catch-up, back-up, anticipatory saccades, and disturbances during fixation. The results were analysed statistically. Results: The average pursuit gain was significantly affected in patients for target velocity of 30°/sec (p=0.007. The catch-up and back-up saccades were more common in cases than controls but the difference was not significant (p=0.39 and 0.36 respectively. The anticipatory saccades were significantly more frequent in cases than controls (p<0.0001 for both 15°/sec and 30°/sec target velocities. This was also correlated with the duration of illness. Conclusion: Anticipatory saccades are significantly more frequent during eye tracking in schizophrenia and appear to be an objective marker for the disease.

  10. Materials for occupational eye protectors.

    Science.gov (United States)

    Dain, Stephen J

    2012-03-01

    The selection of lens materials for non-prescription personal protective equipment has been a relatively simple process and has its origins in many studies around the 1970s. The viable materials available at that time were tempered glass, hard resin (n = 1.50) and polycarbonate. The modern spectacle non-prescription eye protector of choice is inevitably hard coated polycarbonate, which has exemplary impact resistant properties. In the prescription lens area, there is a bewildering array of materials of various refractive indices with a variety of coatings. The selection of an ophthalmic lens has optical and cosmetic considerations ahead of impact resistance. In complying with the Australian/New Zealand standard on prescription eye protection, adequate impact resistance must rate as the foremost requirement, with optical and cosmetic considerations as important but lesser considerations. In this review, the evidence on impact resistance of the available materials is presented, the standards set for testing impact resistance are detailed and some guidance is provided for the selection of prescription eye protection materials.

  11. Mitochondrial disorders and the eye

    Directory of Open Access Journals (Sweden)

    O’Neill EC

    2011-09-01

    Full Text Available Nicole J Van Bergen, Rahul Chakrabarti, Evelyn C O'Neill, Jonathan G Crowston, Ian A TrounceCentre for Eye Research Australia, Department of Ophthalmology, University of Melbourne, Victoria, AustraliaAbstract: The clinical significance of disturbed mitochondrial function in the eye has emerged since mitochondrial DNA (mtDNA mutation was described in Leber's hereditary optic neuropathy. The spectrum of mitochondrial dysfunction has become apparent through increased understanding of the contribution of nuclear and somatic mtDNA mutations to mitochondrial dynamics and function. Common ophthalmic manifestations of mitochondrial dysfunction include optic atrophy, pigmentary retinopathy, and ophthalmoplegia. The majority of patients with ocular manifestations of mitochondrial disease also have variable central and peripheral nervous system involvement. Mitochondrial dysfunction has recently been associated with age-related retinal disease including macular degeneration and glaucoma. Therefore, therapeutic targets directed at promoting mitochondrial biogenesis and function offer a potential to both preserve retinal function and attenuate neurodegenerative processes.Keywords: mitochondria, disease, retina, eye, aging, neuroprotection

  12. Dietary Supplementation with a Combination of Lactoferrin, Fish Oil, and Enterococcus faecium WB2000 for Treating Dry Eye: A Rat Model and Human Clinical Study.

    Science.gov (United States)

    Kawashima, Motoko; Nakamura, Shigeru; Izuta, Yusuke; Inoue, Sachiko; Tsubota, Kazuo

    2016-04-01

    To examine the effect of a combined dietary supplement containing fish oil, lactoferrin, zinc, vitamin C, lutein, vitamin E, γ-aminobutanoic acid, and Enterococcus faecium WB2000 on dry eye. A preliminary study in a rat model and a prospective, randomized, double-blind, placebo-controlled study in humans were conducted. Forty Japanese volunteers aged 22 to 59 years were randomized into combined dietary supplement (2 capsules/day; 20 participants) and placebo (vehicle; 19 participants) groups and treated once daily for 8 weeks. Rats received the combined dietary supplement components (10 or 50 mg/kg orally) or vehicle (2% DMSO), and dry eye was mechanically induced for 2 days. Tear production was measured in rats after dry eye was induced. Humans were assessed at baseline and weeks 4 and 8 post-supplementation based on keratoconjunctival epithelial damage; fluorescein tear film breakup time; tear production; biochemical data; information regarding subjective dry eye symptoms by answering a questionnaire; and information regarding adverse events via medical interviews. Supplementation dose-dependently mitigated the decrease in tear production in rats. Among subjects with confirmed dry eye, clinical symptoms improved at weeks 4 and 8 more significantly in the supplementation group than in the placebo group (P<.05). The rate of increase in the Schirmer value was greater in the supplementation group. No adverse events occurred. Supplementation improved objective and subjective dry eye symptoms. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Abnormal Fixational Eye Movements in Amblyopia.

    Science.gov (United States)

    Shaikh, Aasef G; Otero-Millan, Jorge; Kumar, Priyanka; Ghasia, Fatema F

    2016-01-01

    Fixational saccades shift the foveal image to counteract visual fading related to neural adaptation. Drifts are slow eye movements between two adjacent fixational saccades. We quantified fixational saccades and asked whether their changes could be attributed to pathologic drifts seen in amblyopia, one of the most common causes of blindness in childhood. Thirty-six pediatric subjects with varying severity of amblyopia and eleven healthy age-matched controls held their gaze on a visual target. Eye movements were measured with high-resolution video-oculography during fellow eye-viewing and amblyopic eye-viewing conditions. Fixational saccades and drifts were analyzed in the amblyopic and fellow eye and compared with controls. We found an increase in the amplitude with decreased frequency of fixational saccades in children with amblyopia. These alterations in fixational eye movements correlated with the severity of their amblyopia. There was also an increase in eye position variance during drifts in amblyopes. There was no correlation between the eye position variance or the eye velocity during ocular drifts and the amplitude of subsequent fixational saccade. Our findings suggest that abnormalities in fixational saccades in amblyopia are independent of the ocular drift. This investigation of amblyopia in pediatric age group quantitatively characterizes the fixation instability. Impaired properties of fixational saccades could be the consequence of abnormal processing and reorganization of the visual system in amblyopia. Paucity in the visual feedback during amblyopic eye-viewing condition can attribute to the increased eye position variance and drift velocity.

  14. Occupational eye dose in interventional cardiology procedures.

    Science.gov (United States)

    Haga, Yoshihiro; Chida, Koichi; Kaga, Yuji; Sota, Masahiro; Meguro, Taiichiro; Zuguchi, Masayuki

    2017-04-03

    It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRIS(TM). We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R(2) = 0.93 and R(2) = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.

  15. Eye Vision Testing System and Eyewear Using Micromachines

    Directory of Open Access Journals (Sweden)

    Nabeel A. Riza

    2015-11-01

    Full Text Available Proposed is a novel eye vision testing system based on micromachines that uses micro-optic, micromechanic, and microelectronic technologies. The micromachines include a programmable micro-optic lens and aperture control devices, pico-projectors, Radio Frequency (RF, optical wireless communication and control links, and energy harvesting and storage devices with remote wireless energy transfer capabilities. The portable lightweight system can measure eye refractive powers, optimize light conditions for the eye under testing, conduct color-blindness tests, and implement eye strain relief and eye muscle exercises via time sequenced imaging. A basic eye vision test system is built in the laboratory for near-sighted (myopic vision spherical lens refractive error correction. Refractive error corrections from zero up to −5.0 Diopters and −2.0 Diopters are experimentally demonstrated using the Electronic-Lens (E-Lens and aperture control methods, respectively. The proposed portable eye vision test system is suited for children’s eye tests and developing world eye centers where technical expertise may be limited. Design of a novel low-cost human vision corrective eyewear is also presented based on the proposed aperture control concept. Given its simplistic and economical design, significant impact can be created for humans with vision problems in the under-developed world.

  16. Gaze and eye-tracking solutions for psychological research.

    Science.gov (United States)

    Mele, Maria Laura; Federici, Stefano

    2012-08-01

    Eye-tracking technology is a growing field used to detect eye movements and analyze human processing of visual information for interactive and diagnostic applications. Different domains in scientific research such as neuroscience, experimental psychology, computer science and human factors can benefit from eye-tracking methods and techniques to unobtrusively investigate the quantitative evidence underlying visual processes. In order to meet the experimental requirements concerning the variety of application fields, different gaze- and eye-tracking solutions using high-speed cameras are being developed (e.g., eye-tracking glasses, head-mounted or desk-mounted systems), which are also compatible with other analysis devices such as magnetic resonance imaging. This work presents an overview of the main application fields of eye-tracking methodology in psychological research. In particular, two innovative solutions will be shown: (1) the SMI RED-M eye-tracker, a high performance portable remote eye-tracker suitable for different settings, that requires maximum mobility and flexibility; (2) a wearable mobile gaze-tracking device--the SMI eye-tracking glasses--which is suitable for real-world and virtual environment research. For each kind of technology, the functions and different possibilities of application in experimental psychology will be described by focusing on some examples of experimental tasks (i.e., visual search, reading, natural tasks, scene viewing and other information processing) and theoretical approaches (e.g., embodied cognition).

  17. Eye tracking and the translation process

    DEFF Research Database (Denmark)

    Hvelplund, Kristian Tangsgaard

    2014-01-01

    Eye tracking has become increasingly popular as a quantitative research method in translation research. This paper discusses some of the major methodological issues involved in the use of eye tracking in translation research. It focuses specifically on challenges in the analysis and interpretation...... of eye-tracking data as reflections of cognitive processes during translation. Four types of methodological issues are discussed in the paper. The first part discusses the preparatory steps that precede the actual recording of eye-tracking data. The second part examines critically the general assumptions...... linking eye movements to cognitive processing in the context of translation research. The third part of the paper discusses two popular eye-tracking measures often used in translation research, fixations and pupil size, while the fourth part proposes a method to evaluate the quality of eye-tracking data....

  18. Reconstruction of eye movements during blinks

    CERN Document Server

    Baptista, M S; Kliegl, R; Engbert, R; Kurths, J

    2008-01-01

    In eye movement research in reading, the amount of data plays a crucial role for the validation of results. A methodological problem for the analysis of the eye movement in reading are blinks, when readers close their eyes. Blinking rate increases with increasing reading time, resulting in high data losses, especially for older adults or reading impaired subjects. We present a method, based on the symbolic sequence dynamics of the eye movements, that reconstructs the horizontal position of the eyes while the reader blinks. The method makes use of an observed fact that the movements of the eyes before closing or after opening contain information about the eyes movements during blinks. Test results indicate that our reconstruction method is superior to methods that use simpler interpolation approaches. In addition, analyses of the reconstructed data show no significant deviation from the usual behavior observed in readers.

  19. Eye tracking and the translation process

    DEFF Research Database (Denmark)

    Hvelplund, Kristian Tangsgaard

    2014-01-01

    Eye tracking has become increasingly popular as a quantitative research method in translation research. This paper discusses some of the major methodological issues involved in the use of eye tracking in translation research. It focuses specifically on challenges in the analysis and interpretation...... of eye-tracking data as reflections of cognitive processes during translation. Four types of methodological issues are discussed in the paper. The first part discusses the preparatory steps that precede the actual recording of eye-tracking data. The second part examines critically the general assumptions...... linking eye movements to cognitive processing in the context of translation research. The third part of the paper discusses two popular eye-tracking measures often used in translation research, fixations and pupil size, while the fourth part proposes a method to evaluate the quality of eye-tracking data....

  20. Ethical Issues in Transnational Eye Banking.

    Science.gov (United States)

    Martin, Dominique E; Kelly, Richard; Jones, Gary L A; Machin, Heather; Pollock, Graeme A

    2017-02-01

    To review ethical issues that may arise in the setting of transnational eye banking activities, such as when exporting or importing corneal tissue for transplantation. A principle-based normative analysis of potential common dilemmas in transnational eye banking activities was performed. Transnational activities in eye banking, like those in other fields involving procurement and use of medical products of human origin, may present a number of ethical issues for policy makers and professionals. Key ethical concerns include the potential impact of export or import activities on self-sufficiency of corneal tissue supply within exporting and importing countries; potential disclosure requirements when obtaining consent or authorization for ocular tissue donation when donations may be exported; and difficulties inherent in assuring equity in the allocation of tissues available for export and in establishing and respecting standards of safety and quality across different jurisdictions. Further analysis of specific ethical issues in eye banking is necessary to inform development of guidelines and other governance tools that will assist policy makers and professionals to support ethical practice.