WorldWideScience

Sample records for hplc method validated

  1. Validated RP-HPLC Method for Quantification of Phenolic ...

    African Journals Online (AJOL)

    Purpose: To evaluate the total phenolic content and antioxidant potential of the methanol extracts of aerial parts and roots of Thymus sipyleus Boiss and also to determine some phenolic compounds using a newly developed and validated reversed phase high performance liquid chromatography (RP-HPLC) method.

  2. Development and Validation of a RP-HPLC Method for the ...

    African Journals Online (AJOL)

    Development and Validation of a RP-HPLC Method for the Simultaneous Determination of Rifampicin and a Flavonoid Glycoside - A Novel ... range, accuracy, precision, limit of detection, limit of quantification, robustness and specificity.

  3. Validated Reverse Phase HPLC Method for the Determination of Impurities in Etoricoxib

    Directory of Open Access Journals (Sweden)

    S. Venugopal

    2011-01-01

    Full Text Available This paper describes the development of reverse phase HPLC method for etoricoxib in the presence of impurities and degradation products generated from the forced degradation studies. The drug substance was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The degradation of etoricoxib was observed under base and oxidation environment. The drug was found stable in other stress conditions studied. Successful separation of the drug from the process related impurities and degradation products were achieved on zorbax SB CN (250 x 4.6 mm 5 μm particle size column using reverse phase HPLC method. The isocratic method employed with a mixture of buffer and acetonitrile in a ratio of 60:40 respectively. Disodium hydrogen orthophosphate (0.02 M is used as buffer and pH adjusted to 7.20 with 1 N sodium hydroxide solution. The HPLC method was developed and validated with respect to linearity, accuracy, precision, specificity and ruggedness.

  4. A Validated Stability-Indicating HPLC Method for Simultaneous Determination of Amoxicillin and Enrofloxacin Combination in an Injectable Suspension

    Directory of Open Access Journals (Sweden)

    Nidal Batrawi

    2017-02-01

    Full Text Available The combination of amoxicillin and enrofloxacin is a well-known mixture of veterinary drugs; it is used for the treatment of Gram-positive and Gram-negative bacteria. In the scientific literature, there is no high-performance liquid chromatography (HPLC-UV method for the simultaneous determination of this combination. The objective of this work is to develop and validate an HPLC method for the determination of this combination. In this regard, a new, simple and efficient reversed-phase HPLC method for simultaneous qualitative and quantitative determination of amoxicillin and enrofloxacin, in an injectable preparation with a mixture of inactive excipients, has been developed and validated. The HPLC separation method was performed using a reversed-phase (RP-C18e (250 mm × 4.0 mm, 5 μm column at room temperature, with a gradient mobile phase of acetonitrile and phosphate buffer containing methanol at pH 5.0, a flow rate of 0.8 mL/min and ultraviolet detection at 267 nm. This method was validated in accordance with the Food and Drug Administration (FDA and the International Conference on Harmonisation (ICH guidelines and showed excellent linearity, accuracy, precision, specificity, robustness, ruggedness, and system suitability results within the acceptance criteria. A stability-indicating study was also carried out and indicated that this method can also be used for purity and degradation evaluation of these formulations.

  5. Development and Validation of HPLC-PDA Assay method of Frangula emodin

    Directory of Open Access Journals (Sweden)

    Deborah Duca

    2016-03-01

    Full Text Available Frangula emodin, (1,3,8-trihydroxy-6-methyl-anthraquinone, is one of the anthraquinone derivatives found abundantly in the roots and bark of a number of plant families traditionally used to treat constipation and haemorrhoids. The present study describes the development and subsequent validation of a specific Assay HPLC method for emodin. The separation was achieved on a Waters Symmetry C18, 4.6 × 250 mm, 5 μm particle size, column at a temperature of 35 °C, with UV detection at 287 and 436 nm. An isocratic elution mode consisting of 0.1% formic acid and 0.01% trifluoroacetic acid as the aqueous mobile phase, and methanol was used. The method was successfully and statistically validated for linearity, range, precision, accuracy, specificity and solution stability.

  6. Validation of a dissolution method with RP-HPLC analysis for Perindopril erbumine and Indapamide combination tablet

    Directory of Open Access Journals (Sweden)

    Jain P.S.

    2012-01-01

    Full Text Available A Dissolution method with high performance liquid chromatography (HPLC analysis was validated for perindopril erbumine and indapamide in combination tablet formulation. The method was validated to meet requirements for a global regulatory filing and this validation included specificity, linearity, accuracy, precision, range, robustness and solution stability studies. The dissolution method, which uses USP apparatus 1 with basket rotating at 100 rpm, 1000 ml of phosphate buffer pH 6.8 as the dissolution medium, and reversed-phased HPLC was carried out at 50⁰C on a 4.6mm×250mm 5μm cyano column that contained USP packing L1 with acetonitrile: buffer pH 2.8::40:60 (v/v, as mobile phase. UV detector was set at 225 nm. A method was found to be selective, linear, accurate and precise in the specified ranges. Intra-day and inter-day variability for method was <2% RSD. This method was successfully used for quantification of perindopril erbumine and indapamide combination tablet formulations.

  7. Two Validated HPLC Methods for the Quantification of Alizarin and other Anthraquinones in Rubia tinctorum Cultivars

    NARCIS (Netherlands)

    Derksen, G.C.H.; Lelyveld, G.P.; Beek, van T.A.; Capelle, A.; Groot, de Æ.

    2004-01-01

    Direct and indirect HPLC-UV methods for the quantitative determination of anthraquinones in dried madder root have been developed, validated and compared. In the direct method, madder root was extracted twice with refluxing ethanol-water. This method allowed the determination of the two major native

  8. Validation of an HPLC method for determination of chemical purity of [18F]fluoromisonidazole ([18F]FMISO)

    International Nuclear Information System (INIS)

    Nascimento, Natalia C.E.S.; Oliveira, Mércia L.; Lima, Fernando R.A.; Silveira, Marina B.; Ferreira, Soraya Z.; Silva, Juliana B.

    2017-01-01

    [ 18 F]Fluoromisonidazole ([ 18 F]FMISO) is a nitroimidazole derivative labelled with fluorine-18 that selectively binds to hypoxic cells. It has been shown to be a suitable PET tracer for imaging hypoxia in tumors as well as in noncancerous tissues. [ 18 F]FMISO was prepared using a TRACERlabMX FDG ® module (GE) with cassettes, software sequence and reagents kits from ABX. In this work, we aimed to develop and to validate a new high performance liquid chromatography (HPLC) method for determination of chemical purity of [ 18 F]FMISO. Analyses were performed with an Agilent chromatograph equipped with radioactivity and UV detectors. [ 18 F]FMISO and impurities were separated on a C18 column by gradient elution with water and acetonitrile. Selectivity, linearity, detection limit (DL), quantification limit (LQ), precision, accuracy and robustness were assessed to demonstrate that the HPLC method is adequate for its intended purpose. The HPLC method showed a good precision, as all RSD values were lower than 5%. Robustness was evaluated considering a variation on parameters such mobile phase gradient and flow rate. Results evidenced that the HPLC method is validated and is suitable for radiochemical purity evaluation of [ 18 F]FMISO, considering operational conditions of our laboratory. As an extension of this work, other analytical methods used for [ 18 F]FMISO quality control should be evaluated, in compliance with good manufacture practice. (author)

  9. Development of a validated HPLC method for the determination of sennoside A and B, two major constituents of Cassia obovata Coll.

    Directory of Open Access Journals (Sweden)

    Ghassemi-Dehkordi Nasrollah

    2014-04-01

    Full Text Available Introduction: Cassia obovata Coll is the only Senna species which grows wild in Iran. In the present study, an optimised reverse High Performance Liquid Chromatography (HPLC validated method was established for quantification of sennosides A and B, the major constituents of C. obovata with a simple and accurate method. Methods: HPLC analysis was done using Waters 515 pump on a Nova-Pak C18 (3.9 × 150 mm. Millennium software was used for the determination of the sennoside A and B in Cassia species and processing the information. The method was validated according to USP 32 requirements. Results: The solvent impact on the selectivity factor and partition coefficient parameters evaluated. Using a conventional RP-18 L1 column, 3.9 × 150 mm, the mobile phase was selected after several trials with different mixtures of water and acetonitrile. Sennosides A and B were determined using the external standard calibration method. Using USP 35-NF 30, the LOD and LOQ were calculated. The reliability of the HPLC-method for analysis of sennoside A + B was validated through its linearity, reproducibility, repeatability, and recovery. Fina1ly ethanol:water (1:1 extracts of Cassia obovata and Cassia angustifolia were standardized by assay of sennoside A and B through above HPLC validated method. Conclusion: Through the above method, determination of sennosides in Cassia species are completely possible. Moreover, through comparing the results, even though sennosides are rich in Cassia angustifolia but, the results shows that C. obovata could be considered as an alternative source for sennosides A and B.

  10. DETERMINATION AND VALIDATION OF MEBHYDROLINE NAPADISYLATE IN TABLETS BY HPLC

    Directory of Open Access Journals (Sweden)

    Lestyo Wulandari

    2010-06-01

    Full Text Available An accurate and sensitive HPLC method has been developed for the determination of mebhydroline napadisylate in the tablet. The Chromatography was performed on a reversed phase C-18 column, using a mobile phase of acetonitrile : ammonia 25% (80 : 20 v/v at ambient temperature 25±5 °C and UV detection operates at 320 nm in an overall analysis time of about 15 min, based on peak area. This HPLC method is selective, precise, and accurate and can be used for routine analysis of pharmaceutical preparation in industrial quality-control laboratories.   Keywords : HPLC, mebhydroline napadisylate, validation

  11. Online identification of chlorogenic acids, sesquiterpene lactones, and flavonoids in the Brazilian arnica Lychnophora ericoides Mart. (Asteraceae) leaves by HPLC-DAD-MS and HPLC-DAD-MS/MS and a validated HPLC-DAD method for their simultaneous analysis.

    Science.gov (United States)

    Gobbo-Neto, Leonardo; Lopes, Norberto P

    2008-02-27

    Lychnophora ericoides Mart. (Asteraceae, Vernonieae) is a plant, endemic to Brazil, with occurrence restricted to the "cerrado" biome. Traditional medicine employs alcoholic and aqueous-alcoholic preparations of leaves from this species for the treatment of wounds, inflammation, and pain. Furthermore, leaves of L. ericoides are also widely used as flavorings for the Brazilian traditional spirit "cachaça". A method has been developed for the extraction and HPLC-DAD analysis of the secondary metabolites of L. ericoides leaves. This analytical method was validated with 11 secondary metabolites chosen to represent the different classes and polarities of secondary metabolites occurring in L. ericoides leaves, and good responses were obtained for each validation parameter analyzed. The same HPLC analytical method was also employed for online secondary metabolite identification by HPLC-DAD-MS and HPLC-DAD-MS/MS, leading to the identification of di- C-glucosylflavones, coumaroylglucosylflavonols, flavone, flavanones, flavonols, chalcones, goyazensolide, and eremantholide-type sesquiterpene lactones and positional isomeric series of chlorogenic acids possessing caffeic and/or ferulic moieties. Among the 52 chromatographic peaks observed, 36 were fully identified and 8 were attributed to compounds belonging to series of caffeoylferuloylquinic and diferuloylquinic acids that could not be individualized from each other.

  12. Development and validation of a stability-indicating RP–HPLC method for estimation of atazanavir sulfate in bulk

    Directory of Open Access Journals (Sweden)

    S. Dey

    2017-04-01

    Full Text Available A stability-indicating reverse phase–high performance liquid chromatography (RP–HPLC method was developed and validated for the determination of atazanavir sulfate in tablet dosage forms using C18 column Phenomenix (250 mm×4.6 mm, 5 μm with a mobile phase consisting of 900 mL of HPLC grade methanol and 100 mL of water of HPLC grade. The pH was adjusted to 3.55 with acetic acid. The mobile phase was sonicated for 10 min and filtered through a 0.45 μm membrane filter at a flow rate of 0.5 mL/min. The detection was carried out at 249 nm and retention time of atazanavir sulfate was found to be 8.323 min. Linearity was observed from 10 to 90 μg/mL (coefficient of determination R2 was 0.999 with equation, y=23.427x+37.732. Atazanavir sulfate was subjected to stress conditions including acidic, alkaline, oxidation, photolysis and thermal degradation, and the results showed that it was more sensitive towards acidic degradation. The method was validated as per ICH guidelines.

  13. Development and validation of a dissolution method using HPLC for diclofenac potassium in oral suspension

    Directory of Open Access Journals (Sweden)

    Alexandre Machado Rubim

    2014-04-01

    Full Text Available The present study describes the development and validation of an in vitro dissolution method for evaluation to release diclofenac potassium in oral suspension. The dissolution test was developed and validated according to international guidelines. Parameters like linearity, specificity, precision and accuracy were evaluated, as well as the influence of rotation speed and surfactant concentration on the medium. After selecting the best conditions, the method was validated using apparatus 2 (paddle, 50-rpm rotation speed, 900 mL of water with 0.3% sodium lauryl sulfate (SLS as dissolution medium at 37.0 ± 0.5°C. Samples were analyzed using the HPLC-UV (PDA method. The results obtained were satisfactory for the parameters evaluated. The method developed may be useful in routine quality control for pharmaceutical industries that produce oral suspensions containing diclofenac potassium.

  14. Development and validation of a RP–HPLC method for the quantization studies of metronidazole in tablets and powders dosage forms

    Directory of Open Access Journals (Sweden)

    Elena Gabriela Oltean,

    2011-12-01

    Full Text Available An isocratic high-performance liquid chromatography (HPLC procedure was developed for the quantitative determination of metronidazole in tablets and powders. HPLC separation was carried out by reversed phasechromatography on Kromasil C18 (250 mm x 4.6 mm i.e.; 5 ìm particle size, held in thermostat at 25°C. The mobile phase consisted of methanol/ 0.1% phosphoric acid aq. (20/80v/v, with a flow rate of 1 ml/min and with UV detection at 317 nm. In order to validate the method, the following parameters have been investigated: linearity (r2=0.9999, range, precision, accuracy, specificity, limit of detection and limit of quantification. The described method can be successfully applied for the analysis of the active pharmaceuticalcompound in tablets and powders. This paper aimed to develop and validate an HPLC sensitive applicable method to determine the quantity of metronidazole in tablets and powders, contributing to the quality and safety control of these types of pharmaceutical preparations.

  15. A Validated, Rapid HPLC-ESI-MS/MS Method for the Determination of Lycopsamine.

    Science.gov (United States)

    Jedlinszki, Nikoletta; Csupor, Dezső

    2015-07-01

    The aim of the present work was to develop and validate an HPLC-MS/MS method for the determination of a major pyrrolizidine alkaloid of comfrey (lycopsamine) in aqueous samples as a basis for the development of a method for the determination of absorption of lycopsamine by human skin. A linear calibration curve was established in the range of 1.32-440 ng. The intraday precision during the 3-day validation period ranged between 0.57 and 2.48% while the interday precision was 1.70% and 1.95% for quality control samples. LOD was 0.014 ng and recovery was above 97%. The lycopsamine content of the samples stored for 9 and 25 days at 22 degrees C, 10 degrees C and -25 degrees C did not vary. These results underline the good repeatability and accuracy of our method and allow the analysis of samples with very low lycopsamine content.

  16. A Validated RP-HPLC Method for the Determination of Atazanavir in Pharmaceutical Dosage Form

    Directory of Open Access Journals (Sweden)

    K. Srinivasu

    2011-01-01

    Full Text Available A validated RP HPLC method for the estimation of atazanavir in capsule dosage form on YMC ODS 150 × 4.6 mm, 5 μ column using mobile phase composition of ammonium dihydrogen phosphate buffer (pH 2.5 with acetonitrile (55:45 v/v. Flow rate was maintained at 1.5 mL/min with 288 nm UV detection. The retention time obtained for atazanavir was at 4.7 min. The detector response was linear in the concentration range of 30 - 600 μg/mL. This method has been validated and shown to be specific, sensitive, precise, linear, accurate, rugged, robust and fast. Hence, this method can be applied for routine quality control of atazanavir in capsule dosage forms as well as in bulk drug.

  17. Vitamin D status assessed by a validated HPLC method: within and between variation in subjects supplemented with vitamin D3

    DEFF Research Database (Denmark)

    Jakobsen, Jette; Bysted, Anette; Andersen, Rikke

    2009-01-01

    Objective. The aim of this study was to develop and validate a high-pressure liquid chromatography (HPLC) method for assessing vitamin D status as 25-hydroxyvitamin D2 (S-25OHD2) and 25-hydroxyvitamin D3 (S-25OHD3) in serum. Material and methods. We assessed the within- and between-subject variat......Objective. The aim of this study was to develop and validate a high-pressure liquid chromatography (HPLC) method for assessing vitamin D status as 25-hydroxyvitamin D2 (S-25OHD2) and 25-hydroxyvitamin D3 (S-25OHD3) in serum. Material and methods. We assessed the within- and between......-subject variation of vitamin D status in serum samples from four different dietary intervention studies in which subjects (n=92) were supplemented with different doses of vitamin D3 (5-12 g/day) and for different durations (4-20 months). Results. The HPLC method was applicable for 4.0-200 nmol S-25OHD/L, while...... the within-day and between-days variations were 3.8 % and 5.7 %, respectively. There was a concentration-dependent difference between results obtained by a commercial radioimmunoassay and results from the HPLC method of -5 to 20 nmol 25OHD/L in the range 10-100 nmol 25OHD/L. The between-subject variation...

  18. Validation of an HPLC method for determination of chemical purity of [{sup 18}F]fluoromisonidazole ([{sup 18}F]FMISO)

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento, Natalia C.E.S.; Oliveira, Mércia L.; Lima, Fernando R.A., E-mail: nataliafleming@hotmail.com, E-mail: mercial@cnen.gov.br, E-mail: falima@cnen.gov.br [Centro Regional de Ciências Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Silveira, Marina B.; Ferreira, Soraya Z.; Silva, Juliana B., E-mail: mbs@cdtn.br, E-mail: zandims@cdtn.br, E-mail: silvajb@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    [{sup 18}F]Fluoromisonidazole ([{sup 18}F]FMISO) is a nitroimidazole derivative labelled with fluorine-18 that selectively binds to hypoxic cells. It has been shown to be a suitable PET tracer for imaging hypoxia in tumors as well as in noncancerous tissues. [{sup 18}F]FMISO was prepared using a TRACERlabMX{sub FDG}® module (GE) with cassettes, software sequence and reagents kits from ABX. In this work, we aimed to develop and to validate a new high performance liquid chromatography (HPLC) method for determination of chemical purity of [{sup 18}F]FMISO. Analyses were performed with an Agilent chromatograph equipped with radioactivity and UV detectors. [{sup 18}F]FMISO and impurities were separated on a C18 column by gradient elution with water and acetonitrile. Selectivity, linearity, detection limit (DL), quantification limit (LQ), precision, accuracy and robustness were assessed to demonstrate that the HPLC method is adequate for its intended purpose. The HPLC method showed a good precision, as all RSD values were lower than 5%. Robustness was evaluated considering a variation on parameters such mobile phase gradient and flow rate. Results evidenced that the HPLC method is validated and is suitable for radiochemical purity evaluation of [{sup 18}F]FMISO, considering operational conditions of our laboratory. As an extension of this work, other analytical methods used for [{sup 18}F]FMISO quality control should be evaluated, in compliance with good manufacture practice. (author)

  19. Development and Validation of a Stability-Indicating RP-HPLC ...

    African Journals Online (AJOL)

    Development and Validation of a Stability-Indicating RP-HPLC Method for ... of Paracetamol, Tramadol HCl and Domperidone in a Combined Dosage Form. ... testing, as well as for quality control of the combined drugs in pharmaceutical ...

  20. Development and validation of an HPLC method for tetracycline-related USP monographs.

    Science.gov (United States)

    Hussien, Emad M

    2014-09-01

    A novel reversed-phase HPLC method was developed and validated for the assay of tetracycline hydrochloride and the limit of 4-epianhydrotetracycline hydrochloride impurity in tetracycline hydrochloride commercial bulk and pharmaceutical products. The method employed L1 (3 µm, 150 × 4.6 mm) columns, a mobile phase of 0.1% phosphoric acid and acetonitrile at a flow rate of 1.0 mL/min, and detection at 280 nm. The separation was performed in HPLC gradient mode. Forced degradation studies showed that tetracycline eluted as a spectrally pure peak and was well resolved from its degradation products. The fast degradation of tetracycline hydrochloride and 4-epianhydrotetracycline hydrochloride in solution was retarded by controlling the autosampler temperature at 4 °C and using 0.1% H3 PO4 as diluent. The robustness of the method was tested starting with the maximum variations allowed in the US Pharmacopeia (USP) general chapter Chromatography . The method was linear over the range 80-120% of the assay concentration (0.1 mg/mL) for tetracycline hydrochloride and 50-150% of the acceptance criteria specified in the individual USP monographs for 4-epianhydrotetracycline hydrochloride. The limit of quantification for 4-epianhydrotetracycline hydrochloride was 0.1 µg/mL, 20 times lower than the acceptance criteria. The method was specific, precise, accurate and robust. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Development and validation of a HPLC method for standardization of herbal and commercial extracts of Myrcia uniflora

    Directory of Open Access Journals (Sweden)

    Andrea N. de L. Batista

    2011-06-01

    Full Text Available Myrcia uniflora Barb. Rodr., Myrtaceae, popularly known as "pedra-hume-caá" in Brazil, is sold as dry extracts in capsules or as tinctures for the treatment of diabetes mellitus. Previous phytochemical studies on this species described the occurrence of the flavonoids mearnsitrin and myricitrin. In the present study, the chromatographic profiles of M. uniflora leaves and commercial extracts were determined using HPLC-PAD. Myricitrin was used as an external standard in the development and validation of the HPLC method. The proposed method is simple, rapid and reliable and can be successfully applied in industry for standardization of herbs and phytomedicines commercialised in Brazil as "pedra-hume-caá".

  2. Development and validation of a HPLC method for standardization of herbal and commercial extracts of Myrcia uniflora

    Directory of Open Access Journals (Sweden)

    Andrea N. de L. Batista

    2011-04-01

    Full Text Available Myrcia uniflora Barb. Rodr., Myrtaceae, popularly known as "pedra-hume-caá" in Brazil, is sold as dry extracts in capsules or as tinctures for the treatment of diabetes mellitus. Previous phytochemical studies on this species described the occurrence of the flavonoids mearnsitrin and myricitrin. In the present study, the chromatographic profiles of M. uniflora leaves and commercial extracts were determined using HPLC-PAD. Myricitrin was used as an external standard in the development and validation of the HPLC method. The proposed method is simple, rapid and reliable and can be successfully applied in industry for standardization of herbs and phytomedicines commercialised in Brazil as "pedra-hume-caá".

  3. Development and Validation of HPLC-DAD and UHPLC-DAD Methods for the Simultaneous Determination of Guanylhydrazone Derivatives Employing a Factorial Design.

    Science.gov (United States)

    Azevedo de Brito, Wanessa; Gomes Dantas, Monique; Andrade Nogueira, Fernando Henrique; Ferreira da Silva-Júnior, Edeildo; Xavier de Araújo-Júnior, João; Aquino, Thiago Mendonça de; Adélia Nogueira Ribeiro, Êurica; da Silva Solon, Lilian Grace; Soares Aragão, Cícero Flávio; Barreto Gomes, Ana Paula

    2017-08-30

    Guanylhydrazones are molecules with great pharmacological potential in various therapeutic areas, including antitumoral activity. Factorial design is an excellent tool in the optimization of a chromatographic method, because it is possible quickly change factors such as temperature, mobile phase composition, mobile phase pH, column length, among others to establish the optimal conditions of analysis. The aim of the present work was to develop and validate a HPLC and UHPLC methods for the simultaneous determination of guanylhydrazones with anticancer activity employing experimental design. Precise, exact, linear and robust HPLC and UHPLC methods were developed and validated for the simultaneous quantification of the guanylhydrazones LQM10, LQM14, and LQM17. The UHPLC method was more economic, with a four times less solvent consumption, and 20 times less injection volume, what allowed better column performance. Comparing the empirical approach employed in the HPLC method development to the DoE approach employed in the UHPLC method development, we can conclude that the factorial design made the method development faster, more practical and rational. This resulted in methods that can be employed in the analysis, evaluation and quality control of these new synthetic guanylhydrazones.

  4. Development of a validated HPLC method for the determination of sennoside A and B, two major constituents of Cassia obovata Coll.

    OpenAIRE

    Ghassemi-Dehkordi Nasrollah; Ghanadian Mustafa; Arabha Sajjad

    2014-01-01

    Introduction: Cassia obovata Coll is the only Senna species which grows wild in Iran. In the present study, an optimised reverse High Performance Liquid Chromatography (HPLC) validated method was established for quantification of sennosides A and B, the major constituents of C. obovata with a simple and accurate method. Methods: HPLC analysis was done using Waters 515 pump on a Nova-Pak C18 (3.9 × 150 mm). Millennium software was used for the determination of the sennoside A and B in Cassia s...

  5. HPLC method validated for the simultaneous analysis of cichoric acid and alkamides in Echinacea purpurea plants and products

    DEFF Research Database (Denmark)

    Mølgaard, Per; Johnsen, Søren; Christensen, Peter

    2003-01-01

    phenolics as well as the lipophilic alkamides are released from the samples, followed by the analytical HPLC procedure for quantitative determination of these compounds. The method is the first one validated for the determination of these two groups of compounds in the same procedure. Naringenin has been...

  6. Analytical Method Development and Validation of Solifenacin in Pharmaceutical Dosage Forms by RP-HPLC

    OpenAIRE

    Shaik, Rihana Parveen; Puttagunta, Srinivasa Babu; Kothapalli Bannoth, Chandrasekar; Challa, Bala Sekhara Reddy

    2014-01-01

    A new, accurate, precise, and robust HPLC method was developed and validated for the determination of solifenacin in tablet dosage form. The chromatographic separation was achieved on an Inertsil ODS 3V C18 (150 mm × 4.6 mm, 5 μm) stationary phase maintained at ambient temperature with a mobile phase combination of monobasic potassium phosphate (pH 3.5) containing 0.1% triethylamine and methanol (gradient mode) at a flow rate of 1.5 mL/min, and the detection was carried out by using UV detect...

  7. Development and validation of a RP- HPLC method for the quantitation studies of bromadiolone in Ratitox F

    Directory of Open Access Journals (Sweden)

    Elena Gabriela Oltean

    2011-12-01

    Full Text Available An isocratic high-performance liquid chromatography (HPLC procedure was developed for the quantitative determination of bromadiolone (hydroxycoumarins in Ratitox F product – rodenticide. HPLC separation was carried out by reversed phase chromatography ODS 2 Hypersil C18 (250 mm x 4.6 mm i.e.; 5 ìm particle size, held in thermostat at 25°C. The mobile phase consisted of methanol/0.1% aqueous solution phosphoric acid (90/10v/v, with a flow rate of 1 ml/min and with UV detection at 265 nm. In order to validate the method, the following parameters have been investigated- linearity (r2 = 0.9999, range, precision, accuracy, specificity, limit of detection and limit of quantification. The described method can be successfully applied for the analysis of Ratitox F – rodenticide.

  8. Validation of an HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface of pharmaceutical manufacturing equipments.

    Science.gov (United States)

    Akl, Magda A; Ahmed, Mona A; Ramadan, Ahmed

    2011-05-15

    In pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with extraction solution (50% water and 50% mobile phase), were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 91.12, 93.8 and 98.7% for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD), were below 1.5%. The method was validated over a concentration range of 1.15-6.92 μg ml(-1). Low quantities of drug residues were determined by HPLC-UV using a Hypersil ODS 5 μm (250×4.6 mm) at 50 °C with an acetonitrile:water:pH 7:pH 5 (39-55-5.5-0.5) mobile phase at flow rate of 1.5 ml min(-1), an injection volume of 20 μl and were detected at 254 nm. A simple, selective and sensitive HPLC-UV assay for the determination of ceftriaxone sodium residues on stainless steel surfaces was developed, validated and applied. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Establishment of inherent stability on piracetam by UPLC/HPLC and development of a validated stability-indicating method

    Directory of Open Access Journals (Sweden)

    Kapendra Sahu

    2017-02-01

    Full Text Available A novel comparative force degradation UPLC assay method was developed and validated for Piracetam and its degradation products. Piracetam was subjected to acid (5 M HCl, neutral (water and alkaline (0.5 M NaOH hydrolytic conditions at 80 °C, as well as to oxidative decomposition (H2O2 at room temperature. Photolytic studies were carried out by exposing this drug into sunlight (60,000–70,000 lux for 2 d. Additionally, the solid drug was subjected to 50 °C for 60 days in a hot air oven for thermal degradation. The UPLC chromatographic separation was performed on Acquity UPLC BEH C18 column (1.7 μm, 2.1 mm × 150 mm using isocratic mode (ACN:water, 25:75 v/v at a flow rate of 0.15 mL min−1 and HPLC chromatographic separation was achieved on phenomenex C18 using isocratic mode (ACN:10 mM ammonium acetate, pH 5.0, 20:80 v/v at a flow rate of 0.9 mL/min. Piracetam was found to degrade only in the base and shows stable behavior under all stress conditions. The UPLC and HPLC linearity of the proposed method was investigated in the range of 10–50 μg mL−1. The r2 value of UPLC and HPLC was found to be 0.999 and 0.999, respectively. Method detection limit (MDL and Method quantification limit (MQL were found to be 0.180 μg mL−1and 1.10 μg mL−1 for UPLC and 0.500 μg mL−1and 1.700 μg mL−1 for HPLC respectively. The %RSD values for intra-day and inter-day precision were <1.2%, confirming that the method was sufficiently precise. The validation studies were carried out fulfilling ICH requirements. The developed method was simple, fast, accurate and precise and hence could be applied for routine quality control analysis of Piracetam in solid dosage forms.

  10. Development and Validation of a HPLC-UV Method for Extraction Optimization and Biological Evaluation of Hot-Water and Ethanolic Extracts of Dendropanax morbifera Leaves

    Directory of Open Access Journals (Sweden)

    Hyung-Jae Choi

    2018-03-01

    Full Text Available Dendropanax morbifera Leveille (Araliaceae has been used in traditional oriental remedies for cancer, inflammation, diabetes, and thrombosis. However, a validated analytical method, standardization, and optimization of extraction conditions with respect to biological activity have not been reported. In this study, a simple and validated HPLC method for identifying and quantifying active substances in D. morbifera was developed. Hot water and ethanolic D. morbifera leaf extracts from different production regions were prepared and evaluated with regard to their chemical compositions and biological activities. The contents of active compounds such as rutin and chlorogenic acid were determined in four samples collected from different regions. The 80% ethanolic extract showed the best antioxidant activity, phenolic content, reducing power, and xanthine oxidase (XO inhibitory activity. The validated HPLC method confirmed the presence of chlorogenic acid and rutin in D. morbifera leaf extracts. The antioxidant and XO inhibitory activity of D. morbifera extract could be attributed to the marker compounds. Collectively, these results suggest that D. morbifera leaves could be beneficial for the treatment or prevention of hyperuricemia-related disease, and the validated HPLC method could be a useful tool for the quality control of food or drug formulations containing D. morbifera.

  11. A validated RP-HPLC method for the determination of Irinotecan hydrochloride residues for cleaning validation in production area

    Directory of Open Access Journals (Sweden)

    Sunil Reddy

    2013-03-01

    Full Text Available Introduction: cleaning validation is an integral part of current good manufacturing practices in pharmaceutical industry. The main purpose of cleaning validation is to prove the effectiveness and consistency of cleaning in a given pharmaceutical production equipment to prevent cross contamination and adulteration of drug product with other active ingredient. Objective: a rapid, sensitive and specific reverse phase HPLC method was developed and validated for the quantitative determination of irinotecan hydrochloride in cleaning validation swab samples. Method: the method was validated using waters symmetry shield RP-18 (250mm x 4.6mm 5 µm column with isocratic mobile phase containing a mixture of 0.02 M potassium di-hydrogen ortho-phosphate, pH adjusted to 3.5 with ortho-phosphoric acid, methanol and acetonitrile (60:20:20 v/v/v. The flow rate of mobile phase was 1.0 mL/min with column temperature of 25°C and detection wavelength at 220nm. The sample injection volume was 100 µl. Results: the calibration curve was linear over a concentration range from 0.024 to 0.143 µg/mL with a correlation coefficient of 0.997. The intra-day and inter-day precision expressed as relative standard deviation were below 3.2%. The recoveries obtained from stainless steel, PCGI, epoxy, glass and decron cloth surfaces were more than 85% and there was no interference from the cotton swab. The detection limit (DL and quantitation limit (QL were 0.008 and 0.023 µg ml-1, respectively. Conclusion: the developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision and solution stability. The overall procedure can be used as part of a cleaning validation program in pharmaceutical manufacture of irinotecan hydrochloride.

  12. Development and Validation of a UV Spectrophotometric and a RP-HPLC Methods for Moexipril Hydrochloride in Pure Form and Pharmaceutical Dosage Form

    International Nuclear Information System (INIS)

    Mastiholimath, V.S.; Gupte, P.P.; Mannur, V.S.

    2012-01-01

    A simple and reliable UV spectrophotometric and high-performance liquid chromatography (HPLC) methods were developed and validated for Moexipril hydrochloride in pure form and pharmaceutical dosage form. The RP-HPLC method was developed on agilant eclipse C 18 , (150 mm x 4.6 mm, 5 μm) with a mobile phase gradient system of 60 % (methanol:acetonitrile (70:30 % v/v)) : 40 % 20 mM ammonium acetate buffer pH 4.5 (v/v) and UV spectrophotometric method was developed in phosphate buffer pH 6.8. The effluent was monitored by SPD-M20A, prominence PDA detector at 210 nm. Calibration curve was linear over the concentration range of 10-35 μg/ml and 1-9 μg/ml for RP-HPLC and UV with a regression coefficient of 0.999. For RP-HPLC method Inter-day and intra-day precision % RSD values were found to be 1.00078 % and 1.49408 % respectively. For UV method 0.73386 % to 1.44111 % for inter day 0.453864 to 1.15542 intra-day precision. Recovery of Moexipril hydrochloride was found to be in the range of 99.8538 % to 101.5614 % and 100.5297586 % to 100.6431587 % for UV and RP-HPLC respectively. The limits of detection (LOD) and quantification (LOQ) for HPLC were 0.98969 and 2.99907 μg/ml, respectively. The developed RP-HPLC and UV spectrophotometric method was successfully applied for the quantitative determination of Moexipril hydrochloride in pharmaceutical dosage. (author)

  13. Gradient HPLC method development and validation for Simultaneous estimation of Rosiglitazone and Gliclazide.

    Directory of Open Access Journals (Sweden)

    Uttam Singh Baghel

    2012-10-01

    Full Text Available Objective: The aim of present work was to develop a gradient RP-HPLC method for simultaneous analysis of rosiglitazone and gliclazide, in a tablet dosage form. Method: Chromatographic system was optimized using a hypersil C18 (250mm x 4.6mm, 5毺 m column with potassium dihydrogen phosphate (pH-7.0 and acetonitrile in the ratio of 60:40, as mobile phase, at a flow rate of 1.0 ml/min. Detection was carried out at 225 nm by a SPD-20A prominence UV/Vis detector. Result: Rosiglitazone and gliclazide were eluted with retention times of 17.36 and 7.06 min, respectively. Beer’s Lambert ’s Law was obeyed over the concentration ranges of 5 to 70 毺 g/ml and 2 to 12 毺 g/ml for rosiglitazone and gliclazide, respectively. Conclusion: The high recovery and low coefficients of variation confirm the suitability of the method for simultaneous analysis of both drugs in a tablets dosage form. Statistical analysis proves that the method is sensitive and significant for the analysis of rosiglitazone and gliclazide in pure and in pharmaceutical dosage form without any interference from the excipients. The method was validated in accordance with ICH guidelines. Validation revealed the method is specific, rapid, accurate, precise, reliable, and reproducible.

  14. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

    OpenAIRE

    Jahan, Md. Sarowar; Islam, Md. Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and...

  15. Development and validation of polar RP-HPLC method for screening for ectoine high-yield strains in marine bacteria with green chemistry.

    Science.gov (United States)

    Chen, Jun; Chen, Jianwei; Wang, Sijia; Zhou, Guangmin; Chen, Danqing; Zhang, Huawei; Wang, Hong

    2018-04-02

    A novel, green, rapid, and precise polar RP-HPLC method has been successfully developed and screened for ectoine high-yield strain in marine bacteria. Ectoine is a polar and extremely useful solute which allows microorganisms to survive in extreme environmental salinity. This paper describes a polar-HPLC method employed polar RP-C18 (5 μm, 250 × 4.6 mm) using pure water as the mobile phase and a column temperature of 30 °C, coupled with a flow rate at 1.0 mL/min and detected under a UV detector at wavelength of 210 nm. Our method validation demonstrates excellent linearity (R 2  = 0.9993), accuracy (100.55%), and a limit of detection LOQ and LOD of 0.372 and 0.123 μgmL -1 , respectively. These results clearly indicate that the developed polar RP-HPLC method for the separation and determination of ectoine is superior to earlier protocols.

  16. Development and validation of an rp-hplc method for simultaneous determination of Ramipril and Amlodipine in tablets

    Directory of Open Access Journals (Sweden)

    Shi-Ying Dai

    2013-12-01

    Full Text Available An rp-hplc method for the simultaneous determination of Ramipril (RP and Amlodipine (AL in tablets was developed and validated by Chinese Pharmacopoeia 2010. The linearity of the proposed method was investigated in the range of 0.01–0.25 mg/mL (r2=0.9998 for RP and 0.014–0.36 mg/mL (r2=0.9997 for AL. The limits of detection (LOD were 0.06 μg/mL and 0.02 μg/mL for RP and AL, and the limits of quantitation (LOQ were 0.2 μg/mL and 0.07 μg/mL, respectively. Some major impurities and degradation products did not disturb the detection of RP and AL and the assay can thus be considered stability-indicating. Keywords: Ramipril, Amlodipine, RP-HPLC, Stability-indicating

  17. A validated bioanalytical HPLC method for pharmacokinetic evaluation of 2-deoxyglucose in human plasma.

    Science.gov (United States)

    Gounder, Murugesan K; Lin, Hongxia; Stein, Mark; Goodin, Susan; Bertino, Joseph R; Kong, Ah-Ng Tony; DiPaola, Robert S

    2012-05-01

    2-Deoxyglucose (2-DG), an analog of glucose, is widely used to interfere with glycolysis in tumor cells and studied as a therapeutic approach in clinical trials. To evaluate the pharmacokinetics of 2-DG, we describe the development and validation of a sensitive HPLC fluorescent method for the quantitation of 2-DG in plasma. Plasma samples were deproteinized with methanol and the supernatant was dried at 45°C. The residues were dissolved in methanolic sodium acetate-boric acid solution. 2-DG and other monosaccharides were derivatized to 2-aminobenzoic acid derivatives in a single step in the presence of sodium cyanoborohydride at 80°C for 45 min. The analytes were separated on a YMC ODS C₁₈ reversed-phase column using gradient elution. The excitation and emission wavelengths were set at 360 and 425 nm. The 2-DG calibration curves were linear over the range of 0.63-300 µg/mL with a limit of detection of 0.5 µg/mL. The assay provided satisfactory intra-day and inter-day precision with RSD less than 9.8%, and the accuracy ranged from 86.8 to 110.0%. The HPLC method is reproducible and suitable for the quantitation of 2-DG in plasma. The method was successfully applied to characterize the pharmacokinetics profile of 2-DG in patients with advanced solid tumors. Copyright © 2011 John Wiley & Sons, Ltd.

  18. New validated method for piracetam HPLC determination in human plasma.

    Science.gov (United States)

    Curticapean, Augustin; Imre, Silvia

    2007-01-10

    The new method for HPLC determination of piracetam in human plasma was developed and validated by a new approach. The simple determination by UV detection was performed on supernatant, obtained from plasma, after proteins precipitation with perchloric acid. The chromatographic separation of piracetam under a gradient elution was achieved at room temperature with a RP-18 LiChroSpher 100 column and aqueous mobile phase containing acetonitrile and methanol. The quantitative determination of piracetam was performed at 200 nm with a lower limit of quantification LLQ=2 microg/ml. For this limit, the calculated values of the coefficient of variation and difference between mean and the nominal concentration are CV%=9.7 and bias%=0.9 for the intra-day assay, and CV%=19.1 and bias%=-7.45 for the between-days assay. For precision, the range was CV%=1.8/11.6 in the intra-day and between-days assay, and for accuracy, the range was bias%=2.3/14.9 in the intra-day and between-days assay. In addition, the stability of piracetam in different conditions was verified. Piracetam proved to be stable in plasma during 4 weeks at -20 degrees C and for 36 h at 20 degrees C in the supernatant after protein precipitation. The new proposed method was used for a bioequivalence study of two medicines containing 800 mg piracetam.

  19. Development and validation of Ketorolac Tromethamine in eye drop formulation by RP-HPLC method

    Directory of Open Access Journals (Sweden)

    G. Sunil

    2017-02-01

    Full Text Available A simple, precise and accurate method was developed and validated for analysis of Ketorolac Tromethamine in eye drop formulation. An isocratic HPLC analysis was performed on Kromosil C18 column (150 cm × 4.6 mm × 5 μm. The compound was separated with the mixture of methanol and ammonium dihydrogen phosphate buffer in the ratio of 55:45 V/V, pH 3.0 was adjusted with O-phosphoric acid as the mobile phase at flow of 1.5 mL min−1. UV detection was performed at 314 nm using photo diode array detection. The retention time was found to be 6.01 min. The system suitability parameters such as theoretical plate count, tailing and percentage RSD between six standard injections were within the limit. The method was validated according to ICH guidelines. Calibrations were linear over the concentration range of 50–150 μg mL−1 as indicated by correlation coefficient (r of 0.999. The robustness of the method was evaluated by deliberately altering the chromatographic conditions. The developed method can be applicable for routine quantitative analysis.

  20. Validated HPLC method for identification and quantification of p-hydroxy benzoic acid and agnuside in Vitex negundo and Vitex trifolia

    Directory of Open Access Journals (Sweden)

    Sonal Shah

    2013-12-01

    Full Text Available A high performance liquid chromatography coupled with photodiode array detection method was developed for the identification and quantification of p-hydroxy benzoic acid and agnuside in the extracts of Vitex negundo and Vitex trifolia. The separation was achieved using acetonitrile and O-phosphoric acid–water (0.5%, v/v as the mobile phase in an isocratic elution mode. Mean retention times of standard p-hydroxy benzoic acid and agnuside were 6.14 and 11.90 min respectively. The developed method was validated as per the ICH guidelines for limit of detection, limit of quantification, linearity, accuracy and precision. Good linearity (r2≥0.999 was observed for both the compounds in wide concentration range. Relative standard deviation values for intra-day and inter-day precision studies were less than 2%. The analytical recoveries of p-hydroxy benzoic acid and agnuside by the developed HPLC method were 93.07% and 106.11% respectively. Two compounds were identified and quantified in leaves and bar extracts of V. negundo and V. trifolia using the developed HPLC method. Keywords: Vitex negundo, Vitex trifolia, HPLC-PDA, p-Hydroxy benzoic acid, Agnuside

  1. Validation of an HPLC method for the simultaneous determination of eletriptan and UK 120.413

    Directory of Open Access Journals (Sweden)

    LJILJANA ZIVANOVIC

    2006-11-01

    Full Text Available Arapid and sensitive RPHPLCmethod was developed for the routine control analysis of eletriptan hydrobromide and its organic impurity UK 120.413 in Relpax® tablets. The chromatography was performed at 20 °Cusing a C18 XTerraTM (5 m, 150 × 4,6 mm column at a flow rate 1.0 ml/min. The drug and its impurity were detected at 225 nm. The mobile phase consisted of TEA (1 % – methanol (67.2:32.8 v/v, the pH of which was adjusted to 6.8 with 85 % orthophosphoric acid. Quantification was accomplished by the internal standard method. The developed RP HPLC method was validated by testing: accuracy, precision, repeatibility, specificity, detection limit, quantification limit, linearity, robustness and sensitivity. High linearity of the analytical procedure was confirmed over the concentration range of 0.05 – 1.00 mg/ml for eletriptan hydrobromide and from 0.10 – 1.50 µg/ml for UK 120.413, with correlation coefficients greater than r = 0.995. The low value of the RSD expressed the good repeatability and precision of the method. Experimental design and a response surface method were used to test robustness of the analytical procedure and to evaluate the effect of variation of the method parameters, namely the mobile phase composition, pH and temperature. They showed small deviations from the method setting. The good recovery and low RSD confirm the suitability of the proposed RP HPLC method for the routine determination of eletriptan hydrobromide and its impurity UK 120.413 in Relpax® tables.

  2. OPTIMIZATION AND VALIDATION OF HPLC METHOD FOR TETRAMETHRIN DETERMINATION IN HUMAN SHAMPOO FORMULATION.

    Science.gov (United States)

    Zeric Stosic, Marina Z; Jaksic, Sandra M; Stojanov, Igor M; Apic, Jelena B; Ratajac, Radomir D

    2016-11-01

    High-performance liquid chromatography (HPLC) method with diode array detection (DAD) were optimized and validated for separation and determination of tetramethrin in an antiparasitic human shampoo. In order to optimize separation conditions, two different columns, different column oven temperatures, as well as mobile phase composition and ratio, were tested. Best separation was achieved on the Supelcosil TM LC-18- DB column (4.6 x 250 mm), particle size 5 jim, with mobile phase methanol : water (78 : 22, v/v) at a flow rate of 0.8 mL/min and at temperature of 30⁰C. The detection wavelength of the detector was set at 220 nm. Under the optimum chromatographic conditions, standard calibration curve was measured with good linearity [r2 = 0.9997]. Accuracy of the method defined as a mean recovery of tetramethrin from shampoo matrix was 100.09%. The advantages of this method are that it can easily be used for the routine analysis of drug tetramethrin in pharmaceutical formulas and in all pharmaceutical researches involving tetramethrin.

  3. Isolation and HPLC method development of azafrin from Alectra parasitica var. chitrakutensis.

    Science.gov (United States)

    Agrawal, Poonam; Laddha, Kirti; Tiwari, Ashok

    2014-01-01

    This study was undertaken to isolate and quantify azafrin in Alectra parasitica (Scrophulariaceae) rhizomes. A simple method for the isolation of carotenoid, azafrin, involves solvent extraction of the dried rhizome powder using a single solvent and further purification by recrystallisation. The structure of the compound was elucidated and confirmed by thin-layer chromatography, infrared spectroscopy, mass spectroscopy and nuclear magnetic resonance spectral analysis. A specific and rapid reversed-phase high-performance liquid chromatography (HPLC) method was developed for the analysis of azafrin. The method was validated for accuracy, precision, linearity and specificity. Validation revealed that the method is specific, accurate, precise, reliable and reproducible. The proposed HPLC method can be used for the identification and quantitative analysis of azafrin in A. parasitica rhizomes.

  4. Development and validation of HPLC analytical method for quantitative determination of metronidazole in human plasma

    International Nuclear Information System (INIS)

    Safdar, K.A.; Shyum, S.B.; Usman, S.

    2016-01-01

    The objective of the present study was to develop a simple, rapid and sensitive reversed-phase high performance liquid chromatographic (RP-HPLC) analytical method with UV detection system for the quantitative determination of metronidazole in human plasma. The chromatographic separation was performed by using C18 RP column (250mm X 4.6mm, 5 meu m) as stationary phase and 0.01M potassium dihydrogen phosphate buffered at pH 3.0 and acetonitrile (83:17, v/v) as mobile phase at flow rate of 1.0 ml/min. The UV detection was carried out at 320nm. The method was validated as per the US FDA guideline for bioanalytical method validation and was found to be selective without interferences from mobile phase components, impurities and biological matrix. The method found to be linear over the concentration range of 0.2812 meu g/ml to 18.0 meu g/ml (r2 = 0.9987) with adequate level of accuracy and precision. The samples were found to be stable under various recommended laboratory and storage conditions. Therefore, the method can be used with adequate level of confidence and assurance for bioavailability, bioequivalence and other pharmacokinetic studies of metronidazole in human. (author)

  5. Stability-Indicating Validated HPLC Method for Analysis of Berberine Hydrochloride and Trimethoprim in Pharmaceutical Dosage Form

    Directory of Open Access Journals (Sweden)

    Jing-Chun Wang

    2013-01-01

    Full Text Available A stability-indicating HPLC method was developed and validated for the determination of berberine hydrochloride and trimethoprim in pharmaceutical dosage form in the presence of degradation products. The proposed RP-HPLC method utilizes an Agilent TC-C18, 4.6 mm × 250 mm, 5 μm, column using a mobile phase consisting of acetonitrile-50 mM potassium dihydrogen phosphate (30 : 70, v/v, pH adjusted to 3 with orthophosphoric acid at a flow rate of 1.0 mL/min and UV detection at 271 nm. The linearity of berberine hydrochloride and trimethoprim was in the range of 2 to 60 μg/mL (r=0.9996 and 1 to 30 μg/mL (r=0.9995, respectively. Repeatability and intermediate precisions were also determined with percentage relative standard deviation (% RSD less than 2.0%. The limits of detection were found to be 9.8 ng/mL for berberine hydrochloride and 2.5 ng/mL for trimethoprim. The mean recoveries for berberine hydrochloride and trimethoprim were 99.8 and 98.8%, respectively. The stability of the two drugs was determined under different conditions and the proposed method has shown effective separation for their degradation products. And the proposed assays method can thus be considered stability-indicating.

  6. A Validated RP-HPLC Method for Simultaneous Estimation of Atenolol and Indapamide in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    G. Tulja Rani

    2011-01-01

    Full Text Available A simple, fast, precise, selective and accurate RP-HPLC method was developed and validated for the simultaneous determination of atenolol and indapamide from bulk and formulations. Chromatographic separation was achieved isocratically on a Waters C18 column (250×4.6 mm, 5 µ particle size using a mobile phase, methanol and water (adjusted to pH 2.7 with 1% orthophosphoric acid in the ratio of 80:20. The flow rate was 1 mL/min and effluent was detected at 230 nm. The retention time of atenolol and indapamide were 1.766 min and 3.407 min. respectively. Linearity was observed in the concentration range of 12.5-150 µg/mL for atenolol and 0.625-7.5 µg/mL for indapamide. Percent recoveries obtained for both the drugs were 99.74-100.06% and 98.65-99.98% respectively. The method was validated according to the ICH guidelines with respect to specificity, linearity, accuracy, precision and robustness. The method developed can be used for the routine analysis of atenolol and indapamide from their combined dosage form.

  7. Development and Validation of a HPLC Method for the Determination of Lacidipine in Pure Form and in Pharmaceutical Dosage Form

    International Nuclear Information System (INIS)

    Vinodh, M.; Vinayak, M.; Rahul, K.; Pankaj, P.

    2012-01-01

    A simple and reliable high-performance liquid chromatography (HPLC) method was developed and validated for Lacidipine in pure form and pharmaceutical dosage form. The method was developed on X bridge C-18 column (150 mm x 4.6 mm, 5 μm) with a mobile phase gradient system of ammonium acetate and acetonitrile. The effluent was monitored by PDA detector at 240 nm. Calibration curve was linear over the concentration range of 50-250 μg/ml. For Intra-day and inter-day precision % RSD values were found to be 0.83 % and 0.41 % respectively. Recovery of Lacidipine was found to be in the range of 99.78-101.76 %. The limits of detection (LOD) and quantification (LOQ) were 1.0 and 7.3 μg/ml respectively. The developed RP-HPLC method was successfully applied for the quantitative determination of lacidipine in pharmaceutical dosage. (author)

  8. A validated solid-liquid extraction method for the HPLC determination of polyphenols in apple tissues Comparison with pressurised liquid extraction.

    Science.gov (United States)

    Alonso-Salces, Rosa M; Barranco, Alejandro; Corta, Edurne; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca

    2005-02-15

    A solid-liquid extraction procedure followed by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a photodiode array detector (DAD) for the determination of polyphenols in freeze-dried apple peel and pulp is reported. The extraction step consists in sonicating 0.5g of freeze-dried apple tissue with 30mL of methanol-water-acetic acid (30:69:1, v/v/v) containing 2g of ascorbic acid/L, for 10min in an ultrasonic bath. The whole method was validated, concluding that it is a robust method that presents high extraction efficiencies (peel: >91%, pulp: >95%) and appropriate precisions (within day: R.S.D. (n = 5) <5%, and between days: R.S.D. (n = 5) <7%) at the different concentration levels of polyphenols that can be found in apple samples. The method was compared with one previously published, consisting in a pressurized liquid extraction (PLE) followed by RP-HPLC-DAD determination. The advantages and disadvantages of both methods are discussed.

  9. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  10. Rapid and Reliable HPLC Method for the Determination of Vitamin ...

    African Journals Online (AJOL)

    Purpose: To develop and validate an accurate, sensitive and reproducible high performance liquid chromatographic (HPLC) method for the quantitation of vitamin C in pharmaceutical samples. Method: The drug and the standard were eluted from Superspher RP-18 (250 mm x 4.6 mm, 10ìm particle size) at 20 0C.

  11. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    Science.gov (United States)

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  12. HPLC method validation for modernization of the tetracycline hydrochloride capsule USP monograph

    Directory of Open Access Journals (Sweden)

    Emad M. Hussien

    2014-12-01

    Full Text Available This paper is a continuation to our previous work aiming at development and validation of a reversed-phase HPLC for modernization of tetracycline-related USP monographs and the USP general chapter . Previous results showed that the method is accurate and precise for the assay of tetracycline hydrochloride and the limit of 4-epianhydrotetracycline impurity in the drug substance and oral suspension monographs. The aim of the current paper is to examine the feasibility of the method for modernization of USP tetracycline hydrochloride capsule monograph. Specificity, linearity, accuracy and precision were examined for tetracycline hydrochloride assay and 4-epianhydrotetracycline limit. The method was linear in the concentration range from 80% to 160% (r>0.9998 of the assay concentration (0.1 mg/mL for tetracycline hydrochloride and from 50% to 150% (r>0.997 of the acceptance criteria specified in tetracycline hydrochloride capsule monograph for 4-epianhydrotetracycline (NMT 3.0%. The recovery at three concentration levels for tetracycline hydrochloride assay was between 99% and 101% and the RSD from six preparations at the concentration 0.1 mg/mL is less than 0.6%. The recovery for 4-epianhydrotetracycline limit procedure over the concentration range from 50% to 150% is between 96% and 102% with RSD less than 5%. The results met the specified acceptance criteria.

  13. A Validated HPLC-DAD Method for Simultaneous Determination of Etodolac and Pantoprazole in Rat Plasma

    Directory of Open Access Journals (Sweden)

    Ali S. Abdelhameed

    2014-01-01

    Full Text Available A simple, sensitive, and accurate HPLC-DAD method has been developed and validated for the simultaneous determination of pantoprazole and etodolac in rat plasma as a tool for therapeutic drug monitoring. Optimal chromatographic separation of the analytes was achieved on a Waters Symmetry C18 column using a mobile phase that consisted of phosphate buffer pH~4.0 as eluent A and acetonitrile as eluent B in a ratio of A : B, 55 : 45 v/v for 6 min, pumped isocratically at a flow rate of 0.8 mL min−1. The eluted analytes were monitored using photodiode array detector set to quantify samples at 254 nm. The method was linear with r2=0.9999 for PTZ and r2=0.9995 for ETD at a concentration range of 0.1–15 and 5–50 μgmL−1 for PTZ and ETD, respectively. The limits of detection were found to be 0.033 and 0.918 μgmL−1 for PTZ and ETD, respectively. The method was statistically validated for linearity, accuracy, precision, and selectivity following the International Conference for Harmonization (ICH guidelines. The reproducibility of the method was reliable with the intra- and interday precision (% RSD <7.76% for PTZ and <7.58 % for ETD.

  14. Development and Validation of Stability Indicating HPTLC and HPLC Methods for Simultaneous Determination of Telmisartan and Atorvastatin in Their Formulations

    Directory of Open Access Journals (Sweden)

    Kaliappan Ilango

    2013-01-01

    Full Text Available The present study describes development and subsequent validation of stability indicating HPLC and HPTLC methods for simultaneous estimation of Telmisartan (TLM and Atorvastatin (ATV in their combined formulation. The proposed RP-HPLC method utilizes a Phenomenex Luna C18 column using acetonitrile: 0.025 M ammonium acetate (38 : 52%, v/v as mobile phase (pH 3.8, flow rate of 1.0 mL/min. Quantification was achieved with UV detection at 281 nm over concentration range of 12 to 72 μg/mL for TLM and 3 to 18 μg/mL for ATV respectively. In HPTLC, separations were performed on silica gel 60 F254 using toluene-methanol-ethyl acetate-acetic acid (5 : 1 : 1 : 0.3, v/v as mobile phase. The compact bands of TLM and ATV at 0.37 ± 0.02 and 0.63 ± 0.01 respectively were scanned at 279 nm. Linear regression analysis revealed linearity in the range of 40 to 240 ng/band for TLM and 10 to 60 ng/band for ATV respectively. For both the methods, dosage form was exposed to thermal, photolytic, acid, alkali and oxidative stress. The methods distinctly separated the drugs and degradation products even in actual samples. In conclusion, the proposed HPLC and HPTLC methods were appropriate for routine quantification of TLM and ATV in tablet formulation.

  15. HPLC determination of plasma dimethylarginines: method validation and preliminary clinical application.

    Science.gov (United States)

    Ivanova, Mariela; Artusi, Carlo; Boffa, Giovanni Maria; Zaninotto, Martina; Plebani, Mario

    2010-11-11

    Asymmetric dimethylarginine (ADMA) has been suggested as a possible marker of endothelial dysfunction, and interest in its use in clinical practice is increasing. However, the potential role of symmetric dimethylarginine (SDMA) as an endogenous marker of renal function, has been less widely investigated. The aims of the present study were therefore to determine reference values for dimethylarginines in plasma after method validation, and to ascertain ADMA plasma concentrations in patients with disorders characterized by endothelial dysfunction; a further end-point was to investigate the relationship between SDMA plasma concentrations and estimated GFR (eGFR) as well as plasmatic creatinine in patients with chronic kidney disease (CKD). HPLC with fluorescence detection was used for the determination of plasma dimethylarginines. To verify the clinical usefulness of ADMA and SDMA, values from 4 groups of patients at a high risk of cardiovascular complications as well renal dysfunction (chronic heart failure n=126; type II diabetes n=43; pulmonary arterial hypertension n=17; chronic kidney disease n=42) were evaluated, and compared with the reference values, obtained from 225 blood donors. The intra- and inter-assay CVs (peadiatric populations, for which the use of eGFR is not recommended. 2010 Elsevier B.V. All rights reserved.

  16. Development and Validation of a Stability-Indicating RP-HPLC Method for Rapid Determination of Doxycycline in Pharmaceutical Bulk and Dosage Forms

    OpenAIRE

    Shabnam Pourmoslemi, Soroush Mirfakhraee, Saeid Yaripour, Ali Mohammadi

    2016-01-01

    Background: A rapid stability-indicating RP-HPLC method for analysis of doxycycline in the presence of its degradation products was developed and validated. Methods: Forced degradation studies were carried out on bulk samples and capsule dosage forms of doxycycline using acid, base, H2O2, heat, and UV light as described by ICH for stress conditions to demonstrate the stability-indicating power of the method. Separations were performed on a Perfectsil® Target ODS column (3-5µm, 125 mm×4 mm), u...

  17. Development and Validation of RP-HPLC Method for the Determination of Adefovir Dipivoxil in Bulk and in Pharmaceutical Formulation

    Directory of Open Access Journals (Sweden)

    Zaheer Ahmed

    2009-01-01

    Full Text Available A rapid and sensitive RP-HPLC method with UV detection (262 nm for routine analysis of adefovir dipivoxil in bulk and in pharmaceutical formulation was developed. Chromatography was performed with mobile phase containing a mixture of acetonitrile and phosphate buffer (50:50, v/v with flow rate 1.0 mL min-l. In the range of 5.0-100 µg/mL, the linearity of adefovir dipivoxil shows a correlation co-efficient of 0.9999. The proposed method was validated by determining sensitivity accuracy, precision, robustness stability, specificity, selectivity and system suitability parameters.

  18. Validation of HPLC method for the simultaneous and quantitative determination of 12 UV-filters in cosmetics.

    Science.gov (United States)

    Nyeborg, M; Pissavini, M; Lemasson, Y; Doucet, O

    2010-02-01

    The aim of the study was the validation of a high-performance liquid chromatography (HPLC) method for the simultaneous and quantitative determination of twelve commonly used organic UV-filters (phenylbenzimidazole sulfonic acid, benzophenone-3, isoamyl p-methoxycinnamate, diethylamino hydroxybenzoyl hexyl benzoate, octocrylene, ethylhexyl methoxycinnamate, ethylhexyl salicylate, butyl methoxydibenzoylmethane, diethylhexyl butamido triazone, ethylhexyl triazone, methylene bis-benzotriazolyl tetramethylbutylphenol and bis-ethylhexyloxyphenol methoxyphenyl triazine) contained in suncare products. The separation and quantitative determination was performed in <30 min, using a Symmetry Shield(R) C18 (5 microm) column from Waters and a mobile phase (gradient mode) consisting of ethanol and acidified water. UV measurements were carried out at multi-wavelengths, according to the absorption of the analytes.

  19. Development and Validation of a Stability-Indicating HPLC Method for the Simultaneous Determination of Florfenicol and Flunixin Meglumine Combination in an Injectable Solution

    Directory of Open Access Journals (Sweden)

    Nidal Batrawi

    2017-01-01

    Full Text Available The combination of the powerful antimicrobial agent florfenicol and the nonsteroidal anti-inflammatory flunixin meglumine is used for the treatment of bovine respiratory disease (BRD and control of BRD-associated pyrexia, in beef and nonlactating dairy cattle. This study describes the development and validation of an HPLC-UV method for the simultaneous determination of florfenicol and flunixin, in an injectable preparation with a mixture of excipients. The proposed RP-HPLC method was developed by a reversed phase- (RP- C18e (250 mm × 4.6 mm, 5 μm column at room temperature, with an isocratic mobile phase of acetonitrile and water mixture, and pH was adjusted to 2.8 using diluted phosphoric acid, a flow rate of 1.0 mL/min, and ultraviolet detection at 268 nm. The stability-indicating method was developed by exposing the drugs to stress conditions of acid and base hydrolysis, oxidation, photodegradation, and thermal degradation; the obtained degraded products were successfully separated from the APIs. This method was validated in accordance with FDA and ICH guidelines and showed excellent linearity, accuracy, precision, specificity, robustness, LOD, LOQ, and system suitability results within the acceptance criteria.

  20. Development and Validation of an HPLC Method for the Analysis of Sirolimus in Drug Products

    Directory of Open Access Journals (Sweden)

    Hadi Valizadeh

    2012-05-01

    Full Text Available Purpose: The aim of this study was to develop a simple, rapid and sensitive reverse phase high performance liquid chromatography (RP-HPLC method for quantification of sirolimus (SRL in pharmaceutical dosage forms. Methods: The chromatographic system employs isocratic elution using a Knauer- C18, 5 mm, 4.6 × 150 mm. Mobile phase consisting of acetonitril and ammonium acetate buffer set at flow rate 1.5 ml/min. The analyte was detected and quantified at 278nm using ultraviolet detector. The method was validated as per ICH guidelines. Results: The standard curve was found to have a linear relationship (r2 > 0.99 over the analytical range of 125–2000ng/ml. For all quality control (QC standards in intraday and interday assay, accuracy and precision range were -0.96 to 6.30 and 0.86 to 13.74 respectively, demonstrating the precision and accuracy over the analytical range. Samples were stable during preparation and analysis procedure. Conclusion: Therefore the rapid and sensitive developed method can be used for the routine analysis of sirolimus such as dissolution and stability assays of pre- and post-marketed dosage forms.

  1. HPLC ‘Multi-Analyte’ Detection Method

    Energy Technology Data Exchange (ETDEWEB)

    Dudar, E. [Plant Protection & Soil Conservation Service of Budapest, Budapest (Hungary)

    2009-07-15

    The application of multi-analyte methods for pesticides carrying chromophoric structures by HPLC is described. Details are given on the materials and methods used. Recorded UV spectra of active substances are presented for allowing the verification of purity and the confirmation of substances eluting from the HPLC column. (author)

  2. Simultaneous determination of naphthalene and anthraquinone derivatives in Rumex nepalensis Spreng. roots by HPLC: comparison of different extraction methods and validation.

    Science.gov (United States)

    Gautam, Raju; Srivastava, Amit; Jachak, Sanjay M

    2011-01-01

    Rumex nepalensis contains mainly anthraquinone and naphthalene derivatives. Although HPLC methods have been reported for the analysis of anthraquinones, neither a phytochemical analysis of Rumex species nor the simultaneous determination of anthraquinone and naphthalene derivatives in other samples has been reported so far. To develop and validate a HPLC method for the simultaneous determination of anthraquinone and naphthalene derivatives in R. nepalensis roots. Anthraquinones and naphthalenes were extracted from R. nepalensis roots by three methods (reflux, ultrasonication and pressurized liquid extraction) using methanol. Separation was achieved on an RP C₁₈ column with a gradient mobile phase consisting of 0.05% orthophosphoric acid in water (solvent A) and methanol (solvent B) using a UV detector (254 nm). Small differences were observed in the contents of anthraquinone and naphthalene derivatives extracted by the three methods. Chrysophanol-8-O-β-D-glucopyranoside and nepodin were detected as major constituents. The method showed a good linearity (r² > 0.9992), high precision (RSD anthraquinones and naphthalenes in R. nepalensis and other Rumex species for both quality control as well as routine analytical purposes. Copyright © 2010 John Wiley & Sons, Ltd.

  3. The establishment of tocopherol reference intervals for Hungarian adult population using a validated HPLC method.

    Science.gov (United States)

    Veres, Gábor; Szpisjak, László; Bajtai, Attila; Siska, Andrea; Klivényi, Péter; Ilisz, István; Földesi, Imre; Vécsei, László; Zádori, Dénes

    2017-09-01

    Evidence suggests that decreased α-tocopherol (the most biologically active substance in the vitamin E group) level can cause neurological symptoms, most likely ataxia. The aim of the current study was to first provide reference intervals for serum tocopherols in the adult Hungarian population with appropriate sample size, recruiting healthy control subjects and neurological patients suffering from conditions without symptoms of ataxia, myopathy or cognitive deficiency. A validated HPLC method applying a diode array detector and rac-tocol as internal standard was utilized for that purpose. Furthermore, serum cholesterol levels were determined as well for data normalization. The calculated 2.5-97.5% reference intervals for α-, β/γ- and δ-tocopherols were 24.62-54.67, 0.81-3.69 and 0.29-1.07 μm, respectively, whereas the tocopherol/cholesterol ratios were 5.11-11.27, 0.14-0.72 and 0.06-0.22 μmol/mmol, respectively. The establishment of these reference intervals may improve the diagnostic accuracy of tocopherol measurements in certain neurological conditions with decreased tocopherol levels. Moreover, the current study draws special attention to the possible pitfalls in the complex process of the determination of reference intervals as well, including the selection of study population, the application of internal standard and method validation and the calculation of tocopherol/cholesterol ratios. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Development and validation of RP-HPLC and UV-spectrophotometric methods for rapid simultaneous estimation of amlodipine and benazepril in pure and fixed dose combination

    Directory of Open Access Journals (Sweden)

    Abhi Kavathia

    2017-05-01

    Full Text Available High-performance liquid chromatographic (HPLC and UV spectrophotometric methods were developed and validated for the quantitative determination of amlodipine besylate (AM and benazepril hydrochloride (BZ. Different analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD and limit of quantification (LOQ were determined according to International Conference on Harmonization ICH Q2B guidelines. The RP-HPLC method was developed by the isocratic technique on a reversed-phase Shodex C-18 5e column. The retention time for AM and BZ was 4.43 min and 5.70 min respectively. The UV spectrophotometric determinations were performed at 237 nm and 366 nm for AM and at 237 nm for BZ. Correlation between absorbance of AM at 237 nm and 366 nm was established and based on developed correlation equation estimation of BZ at 237 nm was carried out. The linearity of the calibration curves for each analyte in the desired concentration range was good (r2 > 0.999 by both the HPLC and UV methods. The method showed good reproducibility and recovery with percent relative standard deviation less than 5%. Moreover, the accuracy and precision obtained with HPLC co-related well with the UV method which implied that UV spectroscopy can be a cheap, reliable and less time consuming alternative for chromatographic analysis. The proposed methods are highly sensitive, precise and accurate and hence successfully applied for determining the assay and in vitro dissolution of a marketed formulation.

  5. Development and validation of RP-HPLC method for estimation of eplerenone in spiked human plasma

    Directory of Open Access Journals (Sweden)

    Paraag Gide

    2012-10-01

    Full Text Available A rapid and simple high performance liquid chromatography (HPLC method with a UV detection (241 nm was developed and validated for estimation of eplerenone from spiked human plasma. The analyte and the internal standard (valdecoxib were extracted with a mixture of dichloromethane and diethyl ether. The chromatographic separation was performed on a HiQSil C-18HS column (250 mm×4.6 mm, 5 μm with a mobile phase consisting of acetonitrile:water (50:50, v/v at flow rate of 1 mL/min. The calibration curve was linear in the range 100–3200 ng/mL and the heteroscedasticity was minimized by using weighted least squares regression with weighting factor 1/X. Keywords: Eplerenone, Liquid–liquid extraction, Weighted regression, HPLC–UV

  6. Development and validation of reversed-phase HPLC gradient method for the estimation of efavirenz in plasma.

    Directory of Open Access Journals (Sweden)

    Shweta Gupta

    Full Text Available Efavirenz is an anti-viral agent of non-nucleoside reverse transcriptase inhibitor category used as a part of highly active retroviral therapy for the treatment of infections of human immune deficiency virus type-1. A simple, sensitive and rapid reversed-phase high performance liquid chromatographic gradient method was developed and validated for the determination of efavirenz in plasma. The method was developed with high performance liquid chromatography using Waters X-Terra Shield, RP18 50 x 4.6 mm, 3.5 μm column and a mobile phase consisting of phosphate buffer pH 3.5 and Acetonitrile. The elute was monitored with the UV-Visible detector at 260 nm with a flow rate of 1.5 mL/min. Tenofovir disoproxil fumarate was used as internal standard. The method was validated for linearity, precision, accuracy, specificity, robustness and data obtained were statistically analyzed. Calibration curve was found to be linear over the concentration range of 1-300 μg/mL. The retention times of efavirenz and tenofovir disoproxil fumarate (internal standard were 5.941 min and 4.356 min respectively. The regression coefficient value was found to be 0.999. The limit of detection and the limit of quantification obtained were 0.03 and 0.1 μg/mL respectively. The developed HPLC method can be useful for quantitative pharmacokinetic parameters determination of efavirenz in plasma.

  7. Development and validation of an RP-HPLC method for quantification of trans-resveratrol in the plant extracts

    Directory of Open Access Journals (Sweden)

    Cvetković Žika S.

    2015-01-01

    Full Text Available New, simple, cost effective, accurate and reproducible RP-HPLC method was developed and validated for the quantification of trans-resveratrol in the extracts of grape exocarp and seeds. The method has proved to be simpler and faster than available methods. Methanol was used as a mobile phase with a flow rate of 1.0 cm3 min-1, while the quantification was effected at 306 nm. The separation was performed at 35°C using a C18 column. The results showed that the peak area response was linear in the concentration range of 1-40 μg cm-3. The values of LOD and LOQ were found to be 0.125 and 0.413 μg cm-3, respectively. The antioxidant activity of the extracts was determined using DPPH assay. The ability of DPPH radicals inhibition decreases in the following order: the extract of grape exocarp > trans-resveratrol standard > the extract of grape seeds. [Projekat Ministarstva nauke Republike Srbije, br. TRp-34012

  8. Development and Validation of a Rapid RP-HPLC Method for the Determination of Venlafaxine Hydrochloride in Pharmaceutical Dosage forms using Experimental Design

    Directory of Open Access Journals (Sweden)

    Vanita Somasekhar

    2009-01-01

    Full Text Available The objective of the current study was to develop a simple, accurate, precise and rapid reversed-phase HPLC method and subsequent validation as per ICH guidelines for the determination of venlafaxine hydrochloride in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a 5 μm Varian® Microsorb-MV 100 C18 column (250 mmx4.6 mm at ambient temperature. A 23 factorial design consisting of 3 factors at 2 levels was set up to standardize the chromatographic conditions. A numerical optimization technique employing the desirability approach was used to locate the optimum chromatographic conditions. The optimum mobile phase consisted of acetonitrile, 0.04 M potassium dihydrogen phosphate buffer and methanol (45:25:30, v/v, with pH adjusted to 5.5 using 10% phosphoric acid solution. The mobile phase was delivered isocratically at a flow rate of 1 mL/min with UV detection at 224 nm. The calibration plots constructed using the optimized chromatographic conditions displayed good linear relationship in the concentration range of 1-50 μg/mL with r=0.9992. The method was validated for precision, accuracy, robustness and recovery. The minimum detectable and minimum quantifiable amounts were found to be 0.568 and 1.72 μg/mL, respectively and the method was found to be reproducible from the statistical data generated. Venlafaxine hydrochloride was eluted at 3.43 min

  9. Resveratrol-Loaded Polymeric Nanoparticles: Validation of an HPLC-PDA Method to Determine the Drug Entrapment and Evaluation of Its Antioxidant Activity

    OpenAIRE

    da Rocha Lindner, Gabriela; Khalil, Najeh Maissar; Mainardes, Rubiana Mara

    2013-01-01

    Poly(lactic acid) (PLA) and PLA-poly(ethylene glycol) (PLA-PEG) nanoparticles containing resveratrol (RVT) were developed, and their antioxidant activity was evaluated. An analytical method using high performance liquid chromatography (HPLC)/photodiode array (PDA) detection was also developed and validated for RVT determination in nanoparticles. The mobile phase consisted of methanol : water (51 : 49, v/v) flowed at 0.9 mL/min, and the PDA detector was set at wavelength of 306 nm. The mean di...

  10. Multiresidue confirmatory method for determination of quinolones in milk by HPLC: method development and validation according to the criteria of Commission Decision 2002/657/EC

    Directory of Open Access Journals (Sweden)

    Federica Ostorero

    2013-04-01

    Full Text Available Veterinary drugs have become an integral part of the livestock production and play an important role in maintaining animal welfare. The use of veterinary medicines may be cause of the presence of drug residues in animal food products if appropriate withdrawal periods are not respected or if contaminated feeds are used. This work presents the development of an high performance liquid chromatography with postcolumn fluorescence derivatization (HPLC-FLD method for the quantitative detection of eight quinolones – norfloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, oxolinic acid, nalidixic acid, and flumequine – in bovine milk. After deproteination and extraction with a metaphosphoric acid 1% w/v/methanol/acetonitrile (60/20/20 v/v/v solution, the sample is partially evaporated and cleaned up on a reversed phase solid phase extraction (SPE cartridge. The extract is analyzed using an HPLC-FLD. Mean recovery ranged between 65-88%. The method is validated as a confirmatory method according to Decision 2002/657/EC. All the verified parameters (linearity, selectivity/specificity, trueness, precision, CC, ruggedness and stability were satisfactory and the method is able to quantify all the analytes in milk in the concentration range 15-60 μg/Kg for danofloxacin and 25-150 μg/Kg for the other quinolones.

  11. An improved HPLC method for determination of colocynthin in colocynth

    Directory of Open Access Journals (Sweden)

    M. Shekarchi

    2015-10-01

    Full Text Available Background and objectives: Colocynthin is the major active secondary metabolite of colocynth, Citrullus colocynthis (L. Schrad, which has been used in traditional and ethno medicine of many countries.  It could be considered as an active marker for quality control of colocynth and its herbal products. Analysis and standardization of colocynth and its herbal preparations are a critical issue for their safe applications in phytotherapy and traditional medicine. In the present work, a simple and efficient sample preparation was developed and optimized through combination of matrix solid phase dispersion and ultrasonic assisted extraction. In addition, analytical reversed-phase HPLC method was optimized for analyzing the concentration of colocynthin in colocynth pulp. Methods: Powdered colocynth pulp was grinded with diatomaceous earth to obtain a homogenous mixture. The blend was mixed with methanol and extracted by sonication, followed by centrifugation and filtration. The analytical chromatographic separation was carried out using Luna C18 in isocratic elution with methanol: isopropanol: water: triflouroacetic acid (30:10:60:0.1 v/v. The method was validated as well.  Results: The validation parameters were determines as follows, linear range (r2 = 0.999, 75-500 μg/mL, precision (intra-day < 2.7%, inter-day = 4.4% and accuracy measured via determination of recovery (90-107%. The limit of detection and quantization were calculated 8.5 and 25.7 μg/mL, respectively. Conclusion: Regarding the relatively high content of colocynthin in colocynth pulp, the validated HPLC method could be applied for quality control of colocynth pulp used in Traditional Persian Medicine.

  12. Ultrasound-assisted extraction of azadirachtin from dried entire fruits of Azadirachta indica A. Juss. (Meliaceae) and its determination by a validated HPLC-PDA method.

    Science.gov (United States)

    de Paula, Joelma Abadia Marciano; Brito, Lucas Ferreira; Caetano, Karen Lorena Ferreira Neves; de Morais Rodrigues, Mariana Cristina; Borges, Leonardo Luiz; da Conceição, Edemilson Cardoso

    2016-01-01

    Azadirachta indica A. Juss., also known as neem, is a Meliaceae family tree from India. It is globally known for the insecticidal properties of its limonoid tetranortriterpenoid derivatives, such as azadirachtin. This work aimed to optimize the azadirachtin ultrasound-assisted extraction (UAE) and validate the HPLC-PDA analytical method for the measurement of this marker in neem dried fruit extracts. Box-Behnken design and response surface methodology (RSM) were used to investigate the effect of process variables on the UAE. Three independent variables, including ethanol concentration (%, w/w), temperature (°C), and material-to-solvent ratio (gmL(-1)), were studied. The azadirachtin content (µgmL(-1)), i.e., dependent variable, was quantified by the HPLC-PDA analytical method. Isocratic reversed-phase chromatography was performed using acetonitrile/water (40:60), a flow of 1.0mLmin(-1), detection at 214nm, and C18 column (250×4.6mm(2), 5µm). The primary validation parameters were determined according to ICH guidelines and Brazilian legislation. The results demonstrated that the optimal UAE condition was obtained with ethanol concentration range of 75-80% (w/w), temperature of 30°C, and material-to-solvent ratio of 0.55gmL(-1). The HPLC-PDA analytical method proved to be simple, selective, linear, precise, accurate and robust. The experimental values of azadirachtin content under optimal UAE conditions were in good agreement with the RSM predicted values and were superior to the azadirachtin content of percolated extract. Such findings suggest that UAE is a more efficient extractive process in addition to being simple, fast, and inexpensive. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Validation for chromatographic and electrophoretic methods

    OpenAIRE

    Ribani, Marcelo; Bottoli, Carla Beatriz Grespan; Collins, Carol H.; Jardim, Isabel Cristina Sales Fontes; Melo, Lúcio Flávio Costa

    2004-01-01

    The validation of an analytical method is fundamental to implementing a quality control system in any analytical laboratory. As the separation techniques, GC, HPLC and CE, are often the principal tools used in such determinations, procedure validation is a necessity. The objective of this review is to describe the main aspects of validation in chromatographic and electrophoretic analysis, showing, in a general way, the similarities and differences between the guidelines established by the dif...

  14. A validated method using RP-HPLC for quantification of reserpine in the Brazilian tree Rauvolfia sellowii Müll. Arg. (Apocynaceae

    Directory of Open Access Journals (Sweden)

    Leopoldo C. Baratto

    2012-01-01

    Full Text Available This study describes a simple, fast and reproducible method using RP-HPLC-UV, in a gradient system, for quantification of reserpine in Rauvolfia sellowii stem bark. The analysis were carried out on a C18 column; mobile phase was water and acetonitrile, and separations were carried out in 10 min, flow rate of 1.0 mL min-1, 25 ºC and 268 nm. The validation data showed that the method was specific, accurate, precise and robust. Results were linear over a range of 0.625-40.0 μg mL-1, and the mean recovery was 95.1%. The amount of reserpine found in the dried stem bark was 0.01% (m/m.

  15. Validation of an HPLC method for quantification of total quercetin in Calendula officinalis extracts

    International Nuclear Information System (INIS)

    Muñoz Muñoz, John Alexander; Morgan Machado, Jorge Enrique; Trujillo González, Mary

    2015-01-01

    Introduction: calendula officinalis extracts are used as natural raw material in a wide range of pharmaceutical and cosmetic preparations; however, there are no official methods for quality control of these extracts. Objective: to validate an HPLC-based analytical method for quantification total quercetin in glycolic and hydroalcoholic extracts of Calendula officinalis. Methods: to quantify total quercetin content in the matrices, it was necessary to hydrolyze flavonoid glycosides under optimal conditions. The chromatographic separation was performed on a C-18 SiliaChrom 4.6x150 mm 5 µm column, adapted to a SiliaChrom 5 um C-18 4.6x10 mm precolumn, with UV detection at 370 nm. The gradient elution was performed with a mobile phase consisting of methanol (MeOH) and phosphoric acid (H 3 PO 4 ) (0.08 % w/v). The quantification was performed through the external standard method and comparison with quercetin reference standard. Results: the studied method selectivity against extract components and degradation products under acid/basic hydrolysis, oxidation and light exposure conditions showed no signals that interfere with the quercetin quantification. It was statistically proved that the method is linear from 1.0 to 5.0 mg/mL. Intermediate precision expressed as a variation coefficient was 1.8 and 1.74 % and the recovery percentage was 102.15 and 101.32 %, for glycolic and hydroalcoholic extracts, respectively. Conclusions: the suggested methodology meets the quality parameters required for quantifying total quercetin, which makes it a useful tool for quality control of C. officinalis extracts. (author)

  16. A validated RP-HPLC method for simultaneous determination of propranolol and valsartan in bulk drug and gel formulation

    Science.gov (United States)

    Imam, Syed Sarim; Ahad, Abdul; Aqil, Mohammed; Sultana, Yasmin; Ali, Asgar

    2013-01-01

    Objective: A simple, precise, and stability indicating high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of propranolol hydrochloride and valsartan in pharmaceutical dosage form. Materials and Methods: The method involves the use of easily available inexpensive laboratory reagents. The separation was achieved on Hypersil ODS C-18 column (250*4.6 mm, i.d., 5 μm particle size) with isocratic flow with UV detector. The mobile phase at a flow rate of 1.0 mL/min consisted of acetonitrile, methanol, and 0.01 M disodium hydrogen phosphate (pH 3.5) in the ratio of 50:35:15 v/v. Results: A linear response was observed over the concentration range 5-50 μg/mL of propranolol and the concentration range 4-32 μg/mL of valsartan. Limit of detection and limit of quantitation for propranolol were 0.27 μg/mL and 0.85 μg/mL, and for valsartan were 0.45 μg/mL and 1.39 μg/mL, respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for linearity, accuracy, precision, specificity, robustness. Conclusion: The analysis concluded that the method was selective for simultaneous estimation of propranolol and valsartan can be potentially used for the estimation of these drugs in combined dosage form. PMID:23559826

  17. Development, Validation and Application of RP-HPLC Method: Simultaneous Determination of Antihistamine and Preservatives with Paracetamol in Liquid Formulations and Human Serum

    OpenAIRE

    Hasan, Najmul; Chaiharn, Mathurot; Toor, Umair Ali; Mirani, Zulfiqar Ali; Sajjad, Ghulam; Sher, Nawab; Aziz, Mubashir; Siddiqui, Farhan Ahmed

    2016-01-01

    In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the mobile phase at flow rate 1.0 mL min-1 using a Hibar? Lichrosorb? C18 column and monitored at wavel...

  18. Development and Validation of an HPLC Method for Simultaneous Determination of Rifampicin, Isoniazid, Pyrazinamide, and Ethambutol Hydrochloride in Pharmaceutical Formulations.

    Science.gov (United States)

    Chellini, Paula R; Lages, Eduardo B; Franco, Pedro H C; Nogueira, Fernando H A; César, Isabela C; Pianetti, Gerson A

    2015-01-01

    Tuberculosis treatment consists of a fixed dose combination of rifampicin (RIF), isoniazid (INH), pyrazinamide (PYZ), and ethambutol hydrochloride (EMB). The combined treatment using various drugs is necessary for patient curing, without recrudescence, and for prevention of drug-resistant mutants, which may occur during treatment. An HPLC-diode array detector (DAD) method for the simultaneous determination of RIF, INH, PYZ, and EMB in fixed dose combination tablets was developed and validated. Chromatographic experiments were performed on an Agilent 1200 HPLC system, and the separation was carried out on a Purospher STAR RP18e (250×4.6 mm id, 5 μm, Merck) analytical column. Gradient elution was carried out with a mobile phase of 20 mM monobasic sodium phosphate buffer with 0.2% triethylamine (pH 7.0) and acetonitrile at a flow rate of 1.5 mL/min. The total run time was 12 min, and the re-equilibration time was 5 min. EMB detection was performed at 210 nm, and RIF, INH, and PYZ were detected at 238 nm, using a DAD. The method proved to be specific, linear (r2>0.99), precise (RSD<2%), accurate, and robust and may be applied to the QC analysis of pharmaceutical formulations.

  19. Quantification of Andrographolide Isolated from Andrographis paniculata Nees Obtained from Traditional Market in Yogyakarta Using Validated HPLC

    Directory of Open Access Journals (Sweden)

    Yandi Syukri

    2016-08-01

    Full Text Available This research was aimed to quantification of andrographolide isolated from A. paniculata Ness found in traditional market in Yogyakarta using validated HPLC to obtain high level content of andrographolide. The extraction of andrographolide from A. paniculata was carried out using ethanol as the solvent. Fractionation and isolation were continued using a non-polar solvent. Next, the extracts were re-crystallized to obtain isolated andrographolide. The identity of the compound was confirmed through an analysis of the melting point, IR spectra, and TLC. The purity of the compound was confirmed by the validated HPLC. The data obtained were then compared using an analytical grade of andrographolide as the standard. The isolated andrographolide confirmed melting point, IR spectra and TLC analysis were similar to the standard andrographolide. The method to determine the content of isolated andrographolide showed an adequate precision, with a relative standard deviation (RSD smaller than 1%. The accuracy showed good recovery values were obtained for all concentrations used. The HPLC method in this study showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for the quantification of andrographolide isolated in A. paniculata. When compared to the standard, the purity of the isolated andrographolide was 95.74 ± 0.29%.

  20. RP-HPLC Method Development and Validation for the Determination and Stability Indicative Studies of Montelukast in Bulk and its Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    A. Patnaik

    2012-01-01

    Full Text Available A simple, precise, accurate, economical and reproducible HPLC method for estimation of montelukast in tablet dosage form has been developed. Quantitative HPLC was performed with Shimadzu LC2010c HT with Winchrom Software with UV-Visible detector (SPD-IOA, PUMP (LC-IOAT and (LC-IOATvp. Phenomenex C8, 5 μm, 25 cm × 4.6 mm i.d. column was used in the study. The mobile phase of ACN: Acetate buffer= 6.5:3.5 of pH 3 were used in this study. The conditions optimized were: flow rate (1 mL/minute, wavelength (222 nm and run time was 20 min. Retention time was found to be 3.08 min. The linearity was found to be in the concentration range of 10-100 μg/mL. The developed method was evaluated in the assay of commercially available tablet moni containing 10 mg of montelukast. The amount of drug in tablet was found to be 10.34 mg/tab for the brand. Results of analysis were validated statistically and by recovery studies. The recovery studies 99.67% was indicative of the accuracy of proposed method. The precision was calculated as repeatability, inter and intraday variation (%RSD for the drug. By using the method, stability of the drug has been studied.

  1. Development and validation of a novel RP-HPLC method for simultaneous determination of paracetamol, phenylephrine hydrochloride, caffeine, cetirizine and nimesulide in tablet formulation

    Directory of Open Access Journals (Sweden)

    A.P. Dewani

    2015-07-01

    Full Text Available The present work describes development and validation of a high-performance liquid chromatography–diode array detection (HPLC–DAD procedure for the analysis of phenylephrine hydrochloride (PHE, paracetamol (PAR, caffeine anhydrous (CAF, cetirizine Dihydrochloride (CET, nimesulide (NIM in pharmaceutical mixture. Effective chromatographic separation of PHE, PAR, CAF, CET and NIM was achieved using a Kinetex-C18 (4.6 mm, 150 mm, 5 mm column with gradient elution of the mobile phase composed of 10 mM phosphate buffer (pH 3.3 and acetonitrile. The elution was a three step gradient elution program step-1 started initially with 2% (by volume acetonitrile and 98% phosphate buffer (pH 3.3 for first 2 min. In step-2 acetonitrile concentration changed linearly to 20% up to 12 min the analysis was concluded by step-3 changing acetonitrile to 2% up to 20 min. The proposed HPLC method was statistically validated with respect to linearity, ranges, precision, accuracy, selectivity and robustness. Calibration curves were linear in the ranges of 5–100, 100–1000 and 10–200 mg/mL for PHE, PAR, CAF, CET and NIM respectively, with correlation coefficients >0.9996. The HPLC method was applied to tablet dosage form in which the analytes were successfully quantified with good recovery values with no interfering peaks from the excipients.

  2. DETERMINATION OF RELATED IMPURITIES IN THE ANILOCAINE SUBSTANCE BY HPLC METHOD

    Directory of Open Access Journals (Sweden)

    D. R. Sabirzyanov

    2017-01-01

    Full Text Available Anilocaine is a local anesthetic from the group of substituted amides, synthesized in the Perm State Pharmaceutical Academy. Anilocaine shows high surface anesthetic, infiltration and conduction anesthesia and shows the high efficiency in the various fields of medical practice. The quality of produced medicines depends on the quality of pharmaceutical substances. The purity is one of the most important parameters of the quality of pharmaceutical substances. The aim of this work was the development and validation of methods for identification of specific impurities in the substance of anilocaine by high-performance liquid chromatography (HPLC. Materials and methods. Studies were performed on liquid chromatography LC-20 Prominence (Shimadzu, Japan equipped with a diode-array detector (SPD-M20A. Chromatographic column was Zorbax SB-C18 (4.6 mm × 250 mm, 5 μm. Validation assessment of the developed method conducted in accordance with the requirements of FP XIII and international requirementsICH (International Conference on Harmonization. Results and discussion. An experiment on the selection of the conditions of chromatographically showed that optimal separation of anilocaine and possible impurities (identified and unidentified by the method of reversed-phase HPLC is observed in isocratic mode, using an eluent based on phosphate buffer pH 3 and acetonitrile. The flow rate of mobile phase is 1 ml/min; wavelength detection is 210 nm. Time check chromatogram is 20 minutes. Conclusion. The method for the quantitative determination of impurities in the substance of anilocaine by high-performance liquid chromatography was developed as the result of the research. The validation procedure of the analytical methods established its specificity, linearity, precision and accuracy. This method is included in the project monograph on substance of anilocaine.

  3. Pyrrolizidine alkaloids in the food chain: development, validation, and application of a new HPLC-ESI-MS/MS sum parameter method.

    Science.gov (United States)

    Cramer, Luise; Schiebel, Hans-Martin; Ernst, Ludger; Beuerle, Till

    2013-11-27

    Contamination of food and feed with pyrrolizidine alkaloids is currently discussed as a potential health risk. Here, we report the development of a new HPLC-ESI-MS/MS sum parameter method to quantitate the pyrrolizidine alkaloid content in complex food matrices. The procedure was validated for honey and culinary herbs. Isotopically labeled 7-O-9-O-dibutyroyl-[9,9-(2)H2]-retronecine was synthesized and utilized as an internal standard for validation and quantitation. The total pyrrolizidine alkaloid content of a sample is expressed as a single sum parameter: retronecine equivalents (RE). Ld/Lq for honey was 0.1 μg RE/kg/0.3 μg RE/kg. For culinary herbs, 1.0 μg RE/kg/3.0 μg RE/kg (dry weight, dw) and 0.1 μg RE/kg/0.3 μg RE/kg (fresh weight, fw) were determined, respectively. The new method was applied to analyze 21 herbal convenience products. Fifteen products (71%) were pyrrolizidine alkaloid positive showing pyrrolizidine alkaloid concentrations ranging from 0.9 to 74 μg RE/kg fw.

  4. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Keywords: Ketotifen, Cetirizine, Stability indicating method, Stressed conditions, Validation. Tropical ... in biological fluids [13] are also reported. Stability indicating HPLC method is reported for ketotifen where drug is ..... paracetamol, cetirizine.

  5. Validation of an HPLC-UV method for the identification and quantification of bioactive amines in chicken meat

    Directory of Open Access Journals (Sweden)

    D.C.S. Assis

    2016-06-01

    Full Text Available ABSTRACT A high-performance liquid chromatography with ultraviolet detection (HPLC-UV method was validated for the study of bioactive amines in chicken meat. A gradient elution system with an ultraviolet detector was used after extraction with trichloroacetic acid and pre-column derivatization with dansyl chloride. Putrescine, cadaverine, histamine, tyramine, spermidine, and spermine standards were used for the evaluation of the following performance parameters: selectivity, linearity, precision, recovery, limits of detection, limits of quantification and ruggedness. The results indicated excellent selectivity, separation of all amines, a coefficient of determination greater than 0.99 and recovery from 92.25 to 102.25% at the concentration of 47.2mg.kg-1, with a limit of detection at 0.3mg.kg-1 and a limit of quantification at 0.9mg.kg-1 for all amines, with the exception of histamine, which exhibited the limit of quantification, of 1mg.kg-1. In conclusion, the performance parameters demonstrated adequacy of the method for the detection and quantification of bioactive amines in chicken meat.

  6. Development and validation of an HPLC-FLD method for milbemectin quantification in dog plasma.

    Science.gov (United States)

    Xu, Qianqian; Xiang, Wensheng; Li, Jichang; Liu, Yong; Yu, Xiaolei; Zhang, Yaoteng; Qu, Mingli

    2010-07-15

    Milbemectin is a widely used veterinary antiparasitic agent. A high-performance liquid chromatography with fluorescent detection (HPLC-FLD) method is described for the determination of milbemectin in dog plasma. The derivative procedure included mixing 1-methylimizole [MI, MI-ACN (1:1, v/v), 100 microL], trifluoroacetic anhydride [TFAA, TFAA-ACN (1:2, v/v), 150 microL] with a subsequent incubation for 3s at the room temperature to obtain a fluorescent derivative, which is reproducible in different blood samples and the derivatives proved to be stable for at least 80 h at room temperature. HPLC method was developed on C18 column with FLD detection at an excitation wavelength of 365 nm and emission wavelength of 475 nm, with the mobile phase consisting of methanol and water in the ratio of 98:2 (v/v). The assay lower limit of quantification was 1 ng/mL. The calibration curve was linear over concentration range of 1-200 ng/mL. The intra- and inter-day accuracy was >94% and precision expressed as % coefficient of variation was <5%. This method is specific, simple, accurate, precise and easily adaptable to measure milbemycin in blood of other animals. Crown Copyright 2010. Published by Elsevier B.V. All rights reserved.

  7. Validated RP-HPLC/DAD Method for the Quantification of Insect Repellent Ethyl 2-Aminobenzoate in Membrane-Moderated Matrix Type Monolithic Polymeric Device.

    Science.gov (United States)

    Islam, Johirul; Zaman, Kamaruz; Chakrabarti, Srijita; Sharma Bora, Nilutpal; Mandal, Santa; Pratim Pathak, Manash; Srinivas Raju, Pakalapati; Chattopadhyay, Pronobesh

    2017-07-01

    A simple, accurate and sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the estimation of ethyl 2-aminobenzoate (EAB) in a matrix type monolithic polymeric device and validated as per the International Conference on Harmonization guidelines. The analysis was performed isocratically on a ZORBAX Eclipse plus C18 analytical column (250 × 4.4 mm, 5 μm) and a diode array detector (DAD) using acetonitrile and water (75:25 v/v) as the mobile phase by keeping the flow-rate constant at 1.0 mL/min. Determination of EAB was not interfered in the presence of excipients. Inter- and intra-day relative standard deviations were not higher than 2%. Mean recovery was between 98.7 and 101.3%. Calibration curve was linear in the concentration range of 0.5-10 µg/mL. Limits of detection and quantification were 0.19 and 0.60 µg/mL, respectively. Thus, the present report put forward a novel method for the estimation of EAB, an emerging insect repellent, by using RP-HPLC technique. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Determination of Dyclonine Hydrochloride by a HPLC Method and Camphor and Menthol by a GC Method in Compound Lotion

    Directory of Open Access Journals (Sweden)

    Suying Ma

    2013-01-01

    Full Text Available A high performance liquid chromatographic (HPLC method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC method with flame ionization detector (FID for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18 reversed-phase column (5 μm, 4.6 mm × 200 mm and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm. The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.

  9. Development and Validation of a Precise, Single HPLC Method for the Determination of Tolperisone Impurities in API and Pharmaceutical Dosage Forms.

    Science.gov (United States)

    Raju, Thummala Veera Raghava; Seshadri, Raja Kumar; Arutla, Srinivas; Mohan, Tharlapu Satya Sankarsana Jagan; Rao, Ivaturi Mrutyunjaya; Nittala, Someswara Rao

    2013-01-01

    A novel, sensitive, stability-indicating HPLC method has been developed for the quantitative estimation of Tolperisone-related impurities in both bulk drugs and pharmaceutical dosage forms. Effective chromatographic separation was achieved on a C18 stationary phase with a simple mobile phase combination delivered in a simple gradient programme, and quantitation was by ultraviolet detection at 254 nm. The mobile phase consisted of a buffer and acetonitrile delivered at a flow rate 1.0 ml/min. The buffer consisted of 0.01 M potassium dihydrogen phosphate with the pH adjusted to 8.0 by using diethylamine. In the developed HPLC method, the resolution between Tolperisone and its four potential impurities was found to be greater than 2.0. Regression analysis showed an R value (correlation coefficient) of greater than 0.999 for the Tolperisone impurities. This method was capable of detecting all four impurities of Tolperisone at a level of 0.19 μg/mL with respect to the test concentration of 1000 μg/mL for a 10 µl injection volume. The tablets were subjected to the stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation. Considerable degradation was found to occur in base hydrolysis, water hydrolysis, and oxidation. The stress samples were assayed against a qualified reference standard and the mass balance was found to be close to 100%. The established method was validated and found to be linear, accurate, precise, specific, robust, and rugged.

  10. Development and validation of an HPLC method for the determination of epicatechin in Maytenus ilicifolia (Schrad. Planch., Celastraceae

    Directory of Open Access Journals (Sweden)

    Gisely Cristiny Lopes

    2010-09-01

    Full Text Available A simple, reproducible and efficient high-performance liquid chromatography (HPLC method was developed. Water (0.05% TFA:acetonitrile (0.05% TFA was used as the mobile phase in a gradient system for the determination of epicatechin (EP in leaves of Maytenus ilicifolia (Schrad. Planch. The analysis was performed using an RP C-18 column (5 µm as the stationary phase, with a flow rate of 0.8 mL/min, at a wavelength of 210 nm for detection and determination. The main validation parameters of the method were also determined. The calibration curve was found to be linear, with a range of 10-120 µg/mL (EP. The correlation coefficient of the linear regression analysis was within 0.9988, and the detection and quantification limits were 28.61 and 86.77 µg/mL, respectively. The content of EP was successfully determined, with satisfactory reproducibility and recovery. Recovery of the EP was 99.32%. The method was successfully applied to the determination of epicatechin in leaves of M. ilicifolia. The interlaboratorial evaluation showed the reproducibility of the method with a relative standard deviation of 14.62%.

  11. Pharmacokinetic study of arctigenin in rat plasma and organ tissue by RP-HPLC method.

    Science.gov (United States)

    He, Fan; Dou, De-Qiang; Hou, Qiang; Sun, Yu; Kang, Ting-Guo

    2013-01-01

    A high-performance liquid chromatography (HPLC) technique was developed for the determination of arctigenin in plasma and various organs of rats after the oral administration of 30, 50 and 70 mgkg(-1) of arctigenin to the Sprague-Dawley rats. Results showed that the validated HPLC method was simple, fast, reproducible and suitable to the determination of arctigenin in rat plasma and organ tissue and one-compartmental model with zero-order absorption process can well describe the changes of arctigenin concentration in the plasma. The concentration of compound was highest in the spleen, less in the liver and the least in the lung.

  12. Method validation in pharmaceutical analysis: from theory to practical optimization

    Directory of Open Access Journals (Sweden)

    Jaqueline Kaleian Eserian

    2015-01-01

    Full Text Available The validation of analytical methods is required to obtain high-quality data. For the pharmaceutical industry, method validation is crucial to ensure the product quality as regards both therapeutic efficacy and patient safety. The most critical step in validating a method is to establish a protocol containing well-defined procedures and criteria. A well planned and organized protocol, such as the one proposed in this paper, results in a rapid and concise method validation procedure for quantitative high performance liquid chromatography (HPLC analysis.   Type: Commentary

  13. A Validated Reverse Phase HPLC Analytical Method for Quantitation of Glycoalkaloids in Solanum lycocarpum and Its Extracts

    Directory of Open Access Journals (Sweden)

    Renata Fabiane Jorge Tiossi

    2012-01-01

    Full Text Available Solanum lycocarpum (Solanaceae is native to the Brazilian Cerrado. Fruits of this species contain the glycoalkaloids solasonine (SN and solamargine (SM, which display antiparasitic and anticancer properties. A method has been developed for the extraction and HPLC-UV analysis of the SN and SM in different parts of S. lycocarpum, mainly comprising ripe and unripe fruits, leaf, and stem. This analytical method was validated and gave good detection response with linearity over a dynamic range of 0.77–1000.00 μg mL−1 and recovery in the range of 80.92–91.71%, allowing a reliable quantitation of the target compounds. Unripe fruits displayed higher concentrations of glycoalkaloids (1.04% ± 0.01 of SN and 0.69% ± 0.00 of SM than the ripe fruits (0.83% ± 0.02 of SN and 0.60% ± 0.01 of SM. Quantitation of glycoalkaloids in the alkaloidic extract gave 45.09% ± 1.14 of SN and 44.37% ± 0.60 of SM, respectively.

  14. Analytical method (HPLC, validation used for identification and assay of the pharmaceutical active ingredient, Tylosin tartrate for veterinary use and its finite product Tilodem 50, hydrosoluble powder

    Directory of Open Access Journals (Sweden)

    Maria Neagu

    2010-12-01

    Full Text Available In SC DELOS IMPEX ’96 SRL the quality of the active pharmaceutical ingredient (API for the finite product Tilodem 50 - hydrosoluble powder was acomkplished in the respect of last European Pharmacopoeia.The method for analysis used in this purpose was the compendial method „Tylosin tartrate for veterinary use” in EurPh. in vigour edition and represent a variant developed and validation „in house”.The parameters which was included in the methodology validation for chromatographic method are the followings: Selectivity, Linearity, Linearity range, Detection and Quantification limits, Precision, Repeatability (intra day, Inter-Day Reproductibility, Accuracy, Robustness, Solutions’ stability and System suitability. According to the European Pharmacopoeia, the active pharmaceutical ingredient is consistent, in terms of quality, if it contains Tylosin A - minimum 80% and the amount of Tylosin A, B, C, D, at minimum 95%. Identification and determination of each component separately (Tylosin A, B, C, D is possible by chromatographic separation-HPLC. Validation of analytical methods is presented below.

  15. Simultaneous Chloramphenicol and Florfenicol Determination by A Validated DLLME-HPLC-UV Method in Pasteurized Milk

    OpenAIRE

    Karami-Osboo, Rouhollah; Miri, Ramin; Javidnia, Katayoun; Kobarfard, Farzad

    2016-01-01

    The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 ?g/L with correlation coefficients > 0.999. The proposed method has been found to have a good limit of detection (signal to noise ratio = 3...

  16. New Stability Indicating RP-HPLC Method for the Estimation of Cefpirome Sulphate in Bulk and Pharmaceutical Dosage Forms

    OpenAIRE

    Rao, Kareti Srinivasa; Kumar, Keshar Nargesh; Joydeep, Datta

    2011-01-01

    A simple stability indicating reversed-phase HPLC method was developed and subsequently validated for estimation of Cefpirome sulphate (CPS) present in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a LiChroCART-Lichrosphere100, C18 RP column (250 mm ? 4mm ? 5 ?m) in an isocratic separation mode with mobile phase consisting of methanol and water in the proportion of 50:50 % (v/v), at a flow rate 1ml/min, and the effluent was monitored at 270 nm. The retention time of CPS wa...

  17. Development and validation of an HPLC method for simultaneous determination of trimethoprim and sulfamethoxazole in human plasma.

    Science.gov (United States)

    Sayar, Esin; Sahin, Selma; Cevheroglu, Semsettin; Hincal, A Atilla

    2010-09-01

    The combination of trimethoprim (TMP) and sulfamethoxazole (SMX) is used in the treatment of many common infections such as urinary, respiratory and gastrointestinal tract infections. The aim of this study was to determine TMP and SMX simultaneously in human plasma samples by high performance liquid chromatography (HPLC) using antipyrine as the internal standard. Separation of the compounds was achieved on a reverse-phase C8 column packed with 5 microm dimethyl octadecylsilyl bonded amorphous silica (4.6 mm x 250 mm) column using a mobile phase consisted of potassium hydrogen phosphate, acetonitrile, methanol and water adjusted to pH 6.2. The mobile phase was delivered at a flow rate of 1 mL min- and the effluent was monitored using Max plot technique at 25 derees C. Retention times were 5 min for TMP, 7 min for antipyrine and 9 min for SMX. Quantitation limits were 10 ng mL(-1) for TMP and 50 ng mL(-1) for SMX. Our findings indicated that the developed HPLC method was precise, accurate, specific and sensitive for simultaneous determination of TMP and SMX. Proposed HPLC method was successfully applied for the analysis of TMP and SMX in human plasma after oral administration of a co-trimoxazole tablet to human volunteers.

  18. A Stability-Indicating HPLC-DAD Method for Determination of Ferulic Acid into Microparticles: Development, Validation, Forced Degradation, and Encapsulation Efficiency

    Directory of Open Access Journals (Sweden)

    Jessica Mendes Nadal

    2015-01-01

    Full Text Available A simple stability-indicating HPLC-DAD method was validated for the determination of ferulic acid (FA in polymeric microparticles. Chromatographic conditions consisted of a RP C18 column (250 mm × 4.60 mm, 5 μm, 110 Å using a mixture of methanol and water pH 3.0 (48 : 52 v/v as mobile phase at a flow rate of 1.0 mL/min with UV detection at 320 nm. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of quantification, limit of detection, accuracy, precision, and robustness provided suitable results regarding all parameters investigated. The calibration curve was linear in the concentration range of 10.0–70.0 μg/mL with a correlation coefficient >0.999. Precision (intraday and interday was demonstrated by a relative standard deviation lower than 2.0%. Accuracy was assessed by the recovery test of FA from polymeric microparticles (99.02% to 100.73%. Specificity showed no interference from the components of polymeric microparticles or from the degradation products derived from acidic, basic, and photolytic conditions. In conclusion, the method is suitable to be applied to assay FA as bulk drug and into polymeric microparticles and can be used for studying its stability and degradation kinetics.

  19. Development and Validation of RP-HPLC Method for Simultaneous Estimation of Aspirin and Esomeprazole Magnesium in Tablet Dosage Form

    Directory of Open Access Journals (Sweden)

    Dipali Patel

    2013-01-01

    Full Text Available A simple, specific, precise, and accurate reversed-phase HPLC method was developed and validated for simultaneous estimation of aspirin and esomeprazole magnesium in tablet dosage forms. The separation was achieved by HyperChrom ODS-BP C18 column (200 mm × 4.6 mm; 5.0 μm using acetonitrile: methanol: 0.05 M phosphate buffer at pH 3 adjusted with orthophosphoric acid (25 : 25 : 50, v/v as eluent, at a flow rate of 1 mL/min. Detection was carried out at wavelength 230 nm. The retention times of aspirin and esomeprazole magnesium were 4.29 min and 6.09 min, respectively. The linearity was established over the concentration ranges of 10–70 μg/mL and 10–30 μg/mL with correlation coefficients (r2 0.9986 and 0.9973 for aspirin and esomeprazole magnesium, respectively. The mean recoveries were found to be in the ranges of 99.80–100.57% and 99.70–100.83% for aspirin and esomeprazole magnesium, respectively. The proposed method has been validated as per ICH guidelines and successfully applied to the estimation of aspirin and esomeprazole magnesium in their combined tablet dosage form.

  20. Stability-Indicating RP-HPLC Method for Assay of Silver Lactate

    Directory of Open Access Journals (Sweden)

    V. Srinivasan

    2011-01-01

    Full Text Available A simple, economic and time-efficient stability-indicating, reverse-phase high-performance liquid chromatographic (RP-HPLC method has been developed for analysis of silver lactate in the presence of degradation products generated by decomposition. When silver lactate was subjected to acid hydrolysis, base hydrolysis, oxidative, photolytic, humidity and thermal stress, degradation was observed during base hydrolysis, oxidation, humidity and thermal stress. The drug was found to be stable to other stress conditions. Successful chromatographic condition of the drug from the degradation products formed under stress conditions was achieved on a phenomenex Gemini column with potassium dihydrogen phosphate buffer, pH adjusted to 2.2 with orthophosphoric acid, as mobile phase. The method was validated for linearity, precision, specificity and robustness and can be used for quality-control during manufacture and assessment of the stability of samples of silver lactate. To the best of our knowledge, a validated stability-indicating LC assay method for silver lactate based on lactic acid is reported for the first time.

  1. Development and validation of RP-HPLC method for determination of famotidine and its application in quality control of different pharmaceutical dosage forms

    International Nuclear Information System (INIS)

    Hassan, S.S.; Ayub, M.; Ishtiaq, S.; Ahmad; I; Khalid, N.

    2013-01-01

    A precise and fast novel high-performance liquid chromatography method was developed and validated for the quantitative determination of Famotidine (FMT) in commercially available pharmaceutical dosage forms. An Agilent 1200 Series High Performance Liquid Chromatography (HPLC) system having the column C 1 8 (5 micro m particle size, 150*4.6 mm) was used in this study and detection (diode array detector) was made at 280 nm. The mobile phase was acetonitrile, distilled water, triethylamine and phosphoric acid (49.9:49.9:0.1:0.1, v/v), isocratic elution under ambient temperature at flow rate of 1.5 mL min/sup -1/ with injection volume 5 micro L. In this method, the retention times for FMT pure, tablets and suspension were 0.787 min, 0.789 min and 0.839 minutes respectively. The new method was validated by different validation parameters. The procedure provided a linear response over the concentration range of 0.1-1.0 mg mL/sup -1/ (r/sup 2/ =0.998) and equation was y=3902.6+18.651. The mean % recovery for inter-day (96.56%) and intra-day (97.36%) assuring a good precision and accuracy was 96-98%. The method was found to be very rapid and the overall assay time was less than 2 minutes and the results obtained were accurate, precise and selective enough to allow the determination of FMT in the presence of certain excipients. (author)

  2. Validation and Application of a New Reversed Phase HPLC Method for In Vitro Dissolution Studies of Rabeprazole Sodium in Delayed-Release Tablets

    Directory of Open Access Journals (Sweden)

    Md. Saddam Nawaz

    2013-01-01

    Full Text Available The purpose of this study was to develop and validate a new reversed phase high performance liquid chromatographic (RP-HPLC method to quantify in vitro dissolution assay of rabeprazole sodium in pharmaceutical tablet dosage form. Method development was performed on C 18, 100×4.6 mm ID, and 10 μm particle size column, and injection volume was 20 μL using a diode array detector (DAD to monitor the detection at 280 nm. The mobile phase consisted of buffer: acetonitrile at a ratio of 60 : 40 (v/v, and the flow rate was maintained at 1.0 mL/min. The method was validated in terms of suitability, linearity, specificity, accuracy, precision, stability, and sensitivity. Linearity was observed over the range of concentration 0.05–12.0 μg/mL, and the correlation coefficient was found excellent >0.999. The method was specific with respect to rabeprazole sodium, and the peak purity was found 99.99%. The method was precise and had relative standard deviations (RSD less than 2%. Accuracy was found in the range of 99.9 to 101.9%. The method was robust in different variable conditions and reproducible. This proposed fast, reliable, cost-effective method can be used as quality control tool for the estimation of rabeprazole sodium in routine dissolution test analysis.

  3. Method Development and Validation for the Determination of Caffeine: An Alkaloid from Coffea arabica by High-performance Liquid Chromatography Method.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Deepak, M; Medhini, B; Prasad, K Shyam

    2018-01-01

    The present study was investigated to develop and validate a reversed phase high performance liquid chromatography method for the determination of caffeine from bean material of Coffee arabica. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of water: methanol (50:50) at a flow rate of 1.0 mlmin-1. The detection was carried out on a UV detector at 272 nm. The developed method was validated according to the requirements for International Conference on Harmonisation (ICH) guidelines, which includes specificity, linearity, precision, accuracy, limit of detection and limit of quantitation. The developed method validates good linearity with excellent correlation coefficient (R2 > 0.999). In repeatability and intermediate precision, the percentage relative standard deviation (% RSD) of peak area was less than 1% shows high precision of the method. The recovery rate for caffeine was within 98.78% - 101.28% indicates high accuracy of the method. The low limit of detection and limit of quantitation of caffeine enable the detection and quantitation of caffeine from C. arabica at low concentrations. The developed HPLC method is a simple, rapid, precisely, accurately and widely accepted and it is recommended for efficient assays in routine work. A simple, accurate, and sensitive high-performance liquid chromatography (HPLC) method for caffeine from Coffea arabica has been developed and validated. The developed HPLC method was validated for linearity, specificity, precision, recovery, limits of detection, and limits of quantification by the International Conference on Harmonization guidelines. The results revealed that the proposed method is highly reliable. This method could be successfully applied for routine quality work analysis. Abbreviation Used: C. arabica : Coffee arabica, ICH: International Conference on Harmonisation, % RSD: Percentage Relative Standard Deviation, R2: Correlation Coefficient, ppm: Parts per million, LOD: Limits

  4. Stability-Indicating TLC-Densitometric and HPLC Methods for the Simultaneous Determination of Piracetam and Vincamine in the Presence of Their Degradation Products.

    Science.gov (United States)

    Ahmed, Amal B; Abdelrahman, Maha M; Abdelwahab, Nada S; Salama, Fathy M

    2016-11-01

    Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform-methanol-glacial acetic acid-triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)-methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.

  5. Development and validation of a simple and robust method for arsenic speciation in human urine using HPLC/ICP-MS.

    Science.gov (United States)

    Sen, Indranil; Zou, Wei; Alvaran, Josephine; Nguyen, Linda; Gajek, Ryszard; She, Jianwen

    2015-01-01

    In order to better distinguish the different toxic inorganic and organic forms of arsenic (As) exposure in individuals, we have developed and validated a simple and robust analytical method for determining the following six As species in human urine: arsenous (III) acid (As-III), As (V) acid, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine (AsB), and arsenocholine. In this method, human urine is diluted using a pH 5.8 buffer, separation is performed using an anion exchange column with isocratic HPLC, and detection is achieved using inductively coupled plasma-MS. The method uses a single mobile phase consisting of low concentrations of both phosphate buffer (5 mM) and ammonium nitrate salt (5 mM) at pH 9.0; this minimizes the column equilibration time and overcomes challenges with separation between AsB and As-III. In addition, As-III oxidation is prevented by degassing the sample preparation buffer at pH 5.8, degassing the mobile phase online at pH 9.0, and by the use of low temperature (-70 °C) and flip-cap airtight tubes for long term storage of samples. The method was validated using externally provided reference samples. Results were in agreement with target values at varying concentrations and successfully passed external performance test criteria. Internal QC samples were prepared and repeatedly analyzed to assess the method's long-term precision, and further analyses were completed on anonymous donor urine to assess the quality of the method's baseline separation. Results from analyses of external reference samples agreed with target values at varying concentrations, and results from precision studies yielded absolute CV values of 3-14% and recovery from 82 to 115% for the six As species. Analysis of anonymous donor urine confirmed the well-resolved baseline separation capabilities of the method for real participant samples.

  6. Methods and applications of HPLC-AMS

    International Nuclear Information System (INIS)

    Buchholz, Bruce A.; Dueker, Stephen R.; Lin, Yumei; Clifford, Andrew J.; Vogel, John S.

    2000-01-01

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a 14 C-labeled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the 14 C content above the control predose tissue and converting to equivalents of the parent compound. High performance liquid chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement. Unknowns are tentatively identified by co-elution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the 14 C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of 14 C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected 14 C activity <0.17 Bq (4.5 pCi) on the HPLC column

  7. Determination and validation of six sunscreen agents in suncare products by UPLC and HPLC.

    Science.gov (United States)

    Lee, So-Mi; Jeong, Hye-Jin; Chang, Ih Seop

    2008-01-01

    Methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine are sunscreen agents that have hydrophobic behaviors in common. They were not normally assayed with the following four sunscreen agents that have hydrophilic behaviors in a single chromatographic run: ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. For that reason, methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine require much time in order to assay products with those materials. A rapid, selective, and reproducible determination method needs to be developed for the simultaneous examination of methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine with the sunscreen agents, ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. This new technique could reduce time in examining the sunscreen agents and be effective for quality control of suncare products. In this paper, the HPLC and UPLC system is used for developing the determination of the sunscreen agents. Several evaluations of some mixtures of eluents and columns were obtained for the optimal condition of separation. In HPLC, the optimal peak resolution was obtained through ethanol-water gradient elution and a 75-mm C18 column with a 3.5-microm-sized particle on a flow rate of 1.0 ml/min. In UPLC, the most distinctive peak resolution was obtained through methanol-water gradient elution and a 50-mm C18 column with a 1.7-microm-sized particle on a flow rate 0.4 ml/min. Both of those chromatographic determination methods could be used in the examination of six types of sunscreen agents without any interference from other product excipients in the agents. The proposed determination methods were validated for specificity, linearity, repeatability, system stability, intermediate precision, and accuracy

  8. A Validated Reverse Phase HPLC Method for the Determination of Disodium EDTA in Meropenem Drug Substance with UV-Detection using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2011-01-01

    Full Text Available This paper deals with development and validation of a high performance liquid chromatographic method for the quantitative determination of disodium EDTA (Ethylenediaminetetraacetic acid in Meropenem active pharmaceutical ingredient (API. EDTA was derivatized with Ferric chloride solution by heating at 70 ° C in water bath for about 20 minutes and the chromatographic separation achieved by injecting 100 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a Phenomenex Luna C18(2 column (250 × 4.6 mm, 5 μ, The mobile phase consisting of 5% methanol and 95% of 0.7 g/L solution of Tetra butyl ammonium bromide and 4.6 g/L solution of sodium acetate trihydrate in water (pH adjusted to 4.0 with the help of acetic acid glacial and a flow rate of 1 milliliter/minute. EDTA eluted at approximately 6 minutes. The method was suitably validated with respect to specificity, linearity of response, precision, accuracy, ruggedness, stability in analytical solution, limit of quantitation and detection and robustness for its intended use.

  9. HPLC-Based Method to Evaluate Kinetics of Glucosinolate Hydrolysis by Sinapis alba Myrosinase1

    Science.gov (United States)

    Vastenhout, Kayla J.; Tornberg, Ruthellen H.; Johnson, Amanda L.; Amolins, Michael W.; Mays, Jared R.

    2014-01-01

    Isothiocyanates (ITCs) are one of several hydrolysis products of glucosinolates, plant secondary metabolites which are substrates for the thioglucohydrolase myrosinase. Recent pursuits toward the development of synthetic, non-natural ITCs have consequently led to an exploration of generating these compounds from non-natural glucosinolate precursors. Evaluation of the myrosinase-dependent conversion of select non-natural glucosinolates to non-natural ITCs cannot be accomplished using established UV-Vis spectroscopic methods. To overcome this limitation, an alternative HPLC-based analytical approach was developed where initial reaction velocities were generated from non-linear reaction progress curves. Validation of this HPLC method was accomplished through parallel evaluation of three glucosinolates with UV-Vis methodology. The results of this study demonstrate that kinetic data is consistent between both analytical methods and that the tested glucosinolates respond similarly to both Michaelis–Menten and specific activity analyses. Consequently, this work resulted in the complete kinetic characterization of three glucosinolates with Sinapis alba myrosinase, with results that were consistent with previous reports. PMID:25068719

  10. [Comparative data regarding two HPLC methods for determination of isoniazid].

    Science.gov (United States)

    Gârbuleţ, Daniela; Spac, A F; Dorneanu, V

    2009-01-01

    For the determination of isoniazide (isonicotinic acid hydrazide - HIN) two different HPLC methods were developed and validated. Both experiments were performed using a Waters 2695 liquid chromatograph and a UV - Waters 2489 detector. The first method (I) used a Nucleosil 100-10 C18 column (250 x 4.6 mm), a mobile phase formed by a mixture of acetonitrile/10(-2) M oxalic acid (80/20) and a flow of 1.5 mL/ min; detection was done at 230 nm. The second method (II) used a Luna 100-5 C18 column (250 x 4.6 mm), a mobile phase formed by a mixture of methanol/acetate buffer, pH = 5.0 (20/ 80), a flow of 1 mL/min; detection was done at 270 nm. Both methods were validated, the correlation coefficients were 0.9998 (I) and 0.9999 (II), the detection limits were 0.6 microg/mL (I) and 0.055 microg/mL (II), the quantitation limits were 1.9 microg/mL (I) and 0.2 microg/ mL (II). There were also studied: the system precision (RSD = 0.1692% (I) and 0.2000% (II)), the method precision (RSD = 1.1844% (I) and 0.6170% (II)) and the intermediate precision (RSD = 1.8058% (I) and 0.5970% (II)). The accuracy was good, the calculated recoveries were 102.66% (I) and 101.36 (II). Both validated methods were applied for HIN determination from tablets with good and comparable results.

  11. Development of a validated HPLC method for the quantitative determination of trelagliptin succinate and its related substances in pharmaceutical dosage forms.

    Science.gov (United States)

    Luo, Zhiqiang; Chen, Xinjing; Wang, Guopeng; Du, Zhibo; Ma, Xiaoyun; Wang, Hao; Yu, Guohua; Liu, Aoxue; Li, Mengwei; Peng, Wei; Liu, Yang

    2018-01-01

    Trelagliptin succinate is a dipeptidyl peptidase IV (DPP-4) inhibitor which is used as a new long-acting drug for once-weekly treatment of type 2 diabetes mellitus (DM). In the present study, a rapid, sensitive and accurate high-performance liquid chromatography (HPLC) method was developed and validated for separation and determination of trelagliptin succinate and its eight potential process-related impurities. The chromatographic separation was achieved on a Waters Xselect CSH™ C 18 (250mm×4.6mm, 5.0μm) column. The mobile phases comprised of 0.05% trifluoroacetic acid in water as well as acetonitrile containing 0.05% trifluoroacetic acid. The compounds of interest were monitored at 224nm and 275nm. The stability-indicating capability of this method was evaluated by performing stress test studies. Trelagliptin succinate was found to degrade significantly in acid, base, oxidative and thermal stress conditions and only stable in photolytic degradation condition. The degradation products were well resolved from the main peak and its impurities. In addition, the major degradation impurities formed under acid, base, oxidative and thermal stress conditions were characterized by ultra-high-performance liquid chromatography coupled with linear ion trap-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap). The method was validated to fulfill International Conference on Harmonisation (ICH) requirements and this validation included specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision and robustness. The developed method in this study could be applied for routine quality control analysis of trelagliptin succinate tablets, since there is no official monograph. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Development and validation of RP-HPLC method for analysis of multicomponent cough-cold syrup formulation

    OpenAIRE

    Ivković, Branka; Marković, Bojan; Vladimirov, Sote

    2014-01-01

    In this study a reversed phase HPLC method for rapid and simultaneous identification and quantification of doxylamine succinate, ephedrine sulfate, dextrometorphane hydrobromide, paracetamole and sodium benzoate in cough-cold syrup formulation was described. Separation was carried out on XTerraTM RP 18, Waters (150 mm x 4.6 mm column, 5 μm particle size). For the analysis of investigated substances gradient elution was used employing water, pH adjusted at 2.5 with 85 % ortophosphoric acid as ...

  13. Chemometrics-Assisted UV Spectrophotometric and RP-HPLC Methods for the Simultaneous Determination of Tolperisone Hydrochloride and Diclofenac Sodium in their Combined Pharmaceutical Formulation.

    Science.gov (United States)

    Gohel, Nikunj Rameshbhai; Patel, Bhavin Kiritbhai; Parmar, Vijaykumar Kunvarji

    2013-01-01

    Chemometrics-assisted UV spectrophotometric and RP-HPLC methods are presented for the simultaneous determination of tolperisone hydrochloride (TOL) and diclofenac sodium (DIC) from their combined pharmaceutical dosage form. Chemometric methods are based on principal component regression and partial least-square regression models. Two sets of standard mixtures, calibration sets, and validation sets were prepared. Both models were optimized to quantify each drug in the mixture using the information included in the UV absorption spectra of the appropriate solution in the range 241-290 nm with the intervals λ = 1 nm at 50 wavelengths. The optimized models were successfully applied to the simultaneous determination of these drugs in synthetic mixture and pharmaceutical formulation. In addition, an HPLC method was developed using a reversed-phase C18 column at ambient temperature with a mobile phase consisting of methanol:acetonitrile:water (60:30:10 v/v/v), pH-adjusted to 3.0, with UV detection at 275 nm. The methods were validated in terms of linearity, accuracy, precision, sensitivity, specificity, and robustness in the range of 3-30 μg/mL for TOL and 1-10 μg/mL for DIC. The robustness of the HPLC method was tested using an experimental design approach. The developed HPLC method, and the PCR and PLS models were used to determine the amount of TOL and DIC in tablets. The data obtained from the PCR and PLS models were not significantly different from those obtained from the HPLC method at 95% confidence limit.

  14. Development and validation of a sensitive HPLC method for the quantification of HI-6 in guinea pig plasma and evaluated in domestic swine.

    Science.gov (United States)

    Bohnert, Sara; Vair, Cory; Mikler, John

    2010-05-15

    A rapid and small volume assay to quantify HI-6 in plasma was developed to further the development and licensing of an intravenous formulation of HI-6. The objective of this method was to develop a sensitive and rapid assay that clearly resolved HI-6 and an internal standard in saline and plasma matrices. A fully validated method using ion-pair HPLC and 2-PAM as the internal standard fulfilled these requirements. Small plasma samples of 35 microL were extracted using acidification, filtration and neutralization. Linearity was shown for over 4 microg/mL to 1mg/mL with accuracy and precision within 6% relative error at the lower limit of detection. This method was utilized in the pharmacokinetic analysis HI-6 dichloride (2Cl) and HI-6 dimethane sulfonate (DMS) in anaesthetized guinea pigs and domestic swine following an intravenous bolus administration. From the resultant pharmacokinetic parameters a target plasma concentration of 100 microM was established and maintained in guinea pigs receiving an intravenous infusion. This validated method allows for the analysis of low volume samples, increased sample numbers and is applicable to the determination of pharmacokinetic profiles and parameters. Copyright (c) 2010. Published by Elsevier B.V.

  15. Development and Validation of a HPLC Method for Determination of Pefloxacin in Tablet and Human Plasma

    Directory of Open Access Journals (Sweden)

    Shahnaz Gauhar

    2009-03-01

    Full Text Available Objective(sDeveloping and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (RP-HPLC method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. Materials and MethodsA shim-pack CLC-ODS column and a mobile phase constituting acetonitrile: 0.025 M phosphoric acid solution (13:87 v/v, pH 2.9 adjusted with KOH were used. The flow rate was 1 ml/min and the analyses performed using ultraviolet (UV detector at a wavelength of 275 nm using acetaminophen as an internal standard.ResultsThe developed method showed good resolution between pefloxacin and acetaminophen. It was selective to pefloxacin and able to resolve the drug peak from internal standard and from formulation excipients. The percentage of coefficient variation (CV of the retention times and peak areas of pefloxacin from the six consecutive injections were 0.566% and 0.989%, respectively. The results showed that the peak area responses are linear within the concentration range of 0.125 µg/ml-12 µg/ml (R2= 0.9987. The limits of detection (LOD and limits of quantitation (LOQ for pefloxacin were 0.03125 µg/ml and 0.125 µg/ml. The intra-day and inter-day variation, RSD were 0.376-0.9056 and 0.739-0.853 respectively; also, inter-day variation with relative standard deviation (RSD were 0.1465-0.821 in plasma. The accuracy results of 70%, 100%, and 130% drugs were 100.72%, 100.34%, and 100.09%, respectively.ConclusionThe method is linear, quantitative, reproducible and could be used as a more convenient, efficient and economical method for the trace analysis of drug in biological fluids, in raw material and tablets.

  16. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

    Directory of Open Access Journals (Sweden)

    Md. Sarowar Jahan

    2014-01-01

    Full Text Available A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH. For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8 and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS, 150 × 4.6 mm, 5 μm, Phenomenex Inc. column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient ( R 2 values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient ( R 2 > 0.995. The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%. Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH, while paracetamol showed <20% degradation in oxidation and basic condition.

  17. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method.

    Science.gov (United States)

    Jahan, Md Sarowar; Islam, Md Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R (2)) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R (2) > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH), while paracetamol showed degradation in oxidation and basic condition.

  18. Development and validation of a stability-indicating RP-HPLC method for determination of atomoxetine hydrochloride in tablets.

    Science.gov (United States)

    Patel, Sejal K; Patel, Natvarlal J

    2010-01-01

    This paper describes the development of a stability-indicating RP-HPLC method for the determination of atomoxetine hydrochloride (ATX) in the presence of its degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of acid, base, oxidation, wet heat, dry heat, and photodegradation. In stability tests, the drug was susceptible to acid, base, oxidation, and dry and wet heat degradation. It was found to be stable under the photolytic conditions tested. The drug was successfully separated from the degradation products formed under stress conditions on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) by using acetonitrile-methanol-0.032 M ammonium acetate (55 + 05 + 40, v/v/v) as the mobile phase at 1.0 mL/min and 40 degrees C. Photodiode array detection at 275 nm was used for quantitation after RP-HPLC over the concentration range of 0.5-5 microg/mL with a mean recovery of 100.8 +/- 0.4% for ATX. Statistical analysis demonstrated that the method is repeatable, specific, and accurate for the estimation of ATX. Because the method effectively separates the drug from its degradation products, it can be used as a stability-indicating method.

  19. A rapid and validated HPLC method to quantify sphingosine 1-phosphate in human plasma using solid-phase extraction followed by derivatization with fluorescence detection

    NARCIS (Netherlands)

    Butter, Jan J.; Koopmans, Richard P.; Michel, Martin C.

    2005-01-01

    We describe the development and validation of analytical methodology for the determination of sphingosine 1-phosphate (S1P) in plasma. It uses solid-phase extraction (SPE) followed by an automated reversed-phase gradient HPLC column-switching system with a pre-column derivatization with

  20. A validated stability-indicating RP-HPLC method for paracetamol and lornoxicam: Application to pharmaceutical dosage forms

    Directory of Open Access Journals (Sweden)

    Karunakaran Kulandaivelu

    2014-01-01

    Full Text Available A new method for the simultaneous determination of paracetamol (PR and lornoxicam (LR has been developed by reversed phase HPLC from the combination drug product. The separation achieved on C18 column using acetonitrile and 0.02 M potassium dihydrogen phosphate was in the ratio of 35:65 (v/v as mobile phase at a flow rate of 1.0 mL/min. Both the components were monitored at a single wavelength at 260 nm and the column temperature was maintained at 30°C throughout the analysis. A linear response was found in the concentration range of 125-375 μg/mL for PR and 2-6 μg/mL for LR, with the correlation coefficient of more than 0.999. Although the tablet contained a high dose of PR (500 mg and a low dose of LR (8 mg, the single HPLC method was developed and the intra as well as inter day precision was obtained at less than 2% of RSD. The accuracy results obtained were between 98% and 102%. The drug was intentionally degraded under acidic, basic, peroxide, thermal, and photolytic conditions. The major degradation observed for both PR and LR under peroxide condition indicated that the drug product is susceptible to oxidation. The degraded peaks were properly resolved from PR and LR. Hence, the method is stability indicating.

  1. Development of a new rapid HPLC method for the fractionation of histones

    International Nuclear Information System (INIS)

    Gurley, L.R.; Valdez, J.G.; Prentice, D.A.; Spall, W.D.

    1983-01-01

    To study histone functions, it is necessary to fractionate the histones into their five classes (H1, H2A, H2B, H3 and H4) and then to subfractionate these classes into variants having slightly different primary structures and into different phosphorylated and acetylated forms. With the advent of high-performance liquid chromatography (HPLC), it was hoped that laborious and time-consuming conventional methods could be replaced by a simple, rapid, high-resolving HPLC method for fractionating histones. However, problems of irreversible adsorption of the histones to HPLC column packings discouraged this development. Our laboratory has now determined that the strong adsorption of histones to HPLC columns results from two different forces: (1) polar interactions between the histones and the silanol groups of silica-based HPLC column packing, and (2) hydrophobic interactions between the histones and the bound organic phase of the column packings. By minimizing these forces, we have succeeded in developing an HPLC method suitable for histone studies

  2. Validation of histamine determination Method in yoghurt using High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    M Jahedinia

    2014-02-01

    Full Text Available Biogenic amines are organic, basic nitrogenous compounds of low molecular weight that are mainly generated by the enzymatic decarboxylation of amino acids by microorganisms. Dairy products are among the foods with the highest amine content. A wide variety of methods and procedures for determination of histamine and biogenic amines have been established. Amongst, HPLC method is considered as reference method. The aim of this study was to validate Reversed Phase HPLC method determination of histamine in yoghurt. The mobile phase consisted of acetonitrile/water (18:88 v/v and the flow rate was set at 0.5 ml/min using isocratic HPLC. Detection was carried out at 254 nm using UV-detector. Calibration curve that was constructed using peak area of standards was linear and value of correlation coefficient (r2 was estimated at 0.998. Good recoveries were observed for histamine under investigation at all spiking levels and average of recoveries was 84%. The RSD% value from repeatability test was found to be %4.4. Limit of detection and limit of quantitation were 0.14 and 0.42 µ/ml, respectively. The results of validation tests showed that the method is reliable and rapid for quantification of histamine in yoghurt.

  3. Stability Indicating Reverse Phase HPLC Method for Estimation of Rifampicin and Piperine in Pharmaceutical Dosage Form.

    Science.gov (United States)

    Shah, Umang; Patel, Shraddha; Raval, Manan

    2018-01-01

    High performance liquid chromatography is an integral analytical tool in assessing drug product stability. HPLC methods should be able to separate, detect, and quantify the various drug-related degradants that can form on storage or manufacturing, plus detect any drug-related impurities that may be introduced during synthesis. A simple, economic, selective, precise, and stability-indicating HPLC method has been developed and validated for analysis of Rifampicin (RIFA) and Piperine (PIPE) in bulk drug and in the formulation. Reversed-phase chromatography was performed on a C18 column with Buffer (Potassium Dihydrogen Orthophosphate) pH 6.5 and Acetonitrile, 30:70), (%, v/v), as mobile phase at a flow rate of 1 mL min-1. The detection was performed at 341 nm and sharp peaks were obtained for RIFA and PIPE at retention time of 3.3 ± 0.01 min and 5.9 ± 0.01 min, respectively. The detection limits were found to be 2.385 ng/ml and 0.107 ng/ml and quantification limits were found to be 7.228ng/ml and 0.325ng/ml for RIFA and PIPE, respectively. The method was validated for accuracy, precision, reproducibility, specificity, robustness, and detection and quantification limits, in accordance with ICH guidelines. Stress study was performed on RIFA and PIPE and it was found that these degraded sufficiently in all applied chemical and physical conditions. Thus, the developed RP-HPLC method was found to be suitable for the determination of both the drugs in bulk as well as stability samples of capsule containing various excipients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  4. Stability-Indicating HPLC Method for Simultaneous Determination of Chloramphenicol, Dexamethasone Sodium Phosphate and Tetrahydrozoline Hydrochloride in Ophthalmic Solution.

    Science.gov (United States)

    AlAani, Hashem; Alnukkary, Yasmin

    2016-03-01

    A simple stability-indicating RP-HPLC assay method was developed and validated for quantitative determination of Chloramphenicol, Dexamethasone Sodium Phosphate and Tetrahydrozoline Hydrochloride in ophthalmic solution in the presence of 2-amino-1-(4-nitrophenyl)propane-1,3-diol, a degradation product of Chloramphenicol, and Dexamethasone, a degradation product of Dexamethasone Sodium Phosphate. Effective chromatographic separation was achieved using C18 column (250 mm, 4.6 mm i.d., 5 μm) with isocratic mobile phase consisting of acetonitrile - phosphate buffer (pH 4.0; 0.05 M) (30:70, v/v) at a flow rate of 1 mL/minute. The column temperature was maintained at 40°C and the detection wavelength was 230 nm. The proposed HPLC procedure was statistically validated according to the ICH guideline, and was proved to be stability-indicating by resolution of the APIs from their forced degradation products. The developed method is suitable for the routine analysis as well as stability studies.

  5. Application of Hplc-Pda Method Using Two Different Extraction Procedures for the Determination of Alkylresorcinols in Cereals

    Directory of Open Access Journals (Sweden)

    Gailāne Natālija

    2015-09-01

    Full Text Available Cereals, especially barley, are an important source of vitamins, minerals, dietary fibre and various phytochemicals, such as alkylresorcinols (ARs. Cereal ARs are a group of phenolic lipids located in the outer parts of grain, particularly in rye and wheat, but not found in refined flour or in refined products from cereals. This study focuses on the comparison of different extraction procedures applied for the determination of the content of ARs (C15:0 - C23:0 in grain of Latvian barley genotypes. The content of ARs in 1 rye and 16 barley samples grown with different amounts of fertilier was determined by High Performance Liquid Chromatography method with Photodiode Array detection (HPLC-PDA developed by us. Two different extraction methods were compared: accelerated Soxhlet extraction and 24-hour extraction. Aside from validation of the extraction procedures, validation parameters for the HPLC-PDA based quantitation method were provided. The coefficients of variation for repeatability and intermediate precision were < 9% and < 3%, respectively. The content of ARs determined with the HPLC-PDA method in conjunction with accelerated Soxhlet extraction was up to 1.5 times higher than using 24-hour extraction. AR content varied from 2.11 ± 0.04 to 3.80 ± 0.10 mg·100 g-1 for 24-hour extraction and from 2.66 ± 0.06 to 5.70 ± 0.20 mg·100 g-1 for accelerated Soxhlet extraction, indicating the increased efficiency of this procedure in analysis of ARs.

  6. An Investigation Into HPLC Data Quality Problems

    Science.gov (United States)

    Hooker, Stanford B.; VanHeukelem, Laurie

    2011-01-01

    This report summarizes the analyses and results produced by a five-member investigative team of Government, university, and industry experts, established by NASA HQ. The team examined data quality problems associated with high performance liquid chromatography (HPLC) analyses of pigment concentrations in seawater samples produced by the San Diego State University (SDSU) Center for Hydro-Optics and Remote Sensing (CHORS). This report shows CHORS did not validate the methods used before placing them into service to analyze field samples for NASA principal investigators (PIs), even though the HPLC literature contained easily accessible method validation procedures, and the importance of implementing them, more than a decade ago. In addition, there were so many sources of significant variance in the CHORS methodologies, that the HPLC system rarely operated within performance criteria capable of producing the requisite data quality. It is the recommendation of the investigative team to a) not correct the data, b) make all the data that was temporarily sequestered available for scientific use, and c) label the affected data with an appropriate warning, e.g., "These data are not validated and should not be used as the sole basis for a scientific result, conclusion, or hypothesis--independent corroborating evidence is required."

  7. Development of Reverse-Phase HPLC Method for Simultaneous ...

    African Journals Online (AJOL)

    Erah

    Purpose: To develop a simple, sensitive and rapid reverse phase HPLC method for the simultaneous analysis of metoprolol succinate and hydrochlorothiazide in a solid dosage form. Methods: The .... Extraction was carried out three times with.

  8. A validated RP-HPLC method for the determination of Irinotecan hydrochloride residues for cleaning validation in production area Método RP- HPLC validado para la determinación de residuos de Irinotecan Hidrocloruro para la validación de la limpieza en el área de producción

    Directory of Open Access Journals (Sweden)

    Sunil Reddy

    2013-03-01

    Full Text Available Introduction: cleaning validation is an integral part of current good manufacturing practices in pharmaceutical industry. The main purpose of cleaning validation is to prove the effectiveness and consistency of cleaning in a given pharmaceutical production equipment to prevent cross contamination and adulteration of drug product with other active ingredient. Objective: a rapid, sensitive and specific reverse phase HPLC method was developed and validated for the quantitative determination of irinotecan hydrochloride in cleaning validation swab samples. Method: the method was validated using waters symmetry shield RP-18 (250mm x 4.6mm 5 µm column with isocratic mobile phase containing a mixture of 0.02 M potassium di-hydrogen ortho-phosphate, pH adjusted to 3.5 with ortho-phosphoric acid, methanol and acetonitrile (60:20:20 v/v/v. The flow rate of mobile phase was 1.0 mL/min with column temperature of 25°C and detection wavelength at 220nm. The sample injection volume was 100 µl. Results: the calibration curve was linear over a concentration range from 0.024 to 0.143 µg/mL with a correlation coefficient of 0.997. The intra-day and inter-day precision expressed as relative standard deviation were below 3.2%. The recoveries obtained from stainless steel, PCGI, epoxy, glass and decron cloth surfaces were more than 85% and there was no interference from the cotton swab. The detection limit (DL and quantitation limit (QL were 0.008 and 0.023 µg ml-1, respectively. Conclusion: the developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision and solution stability. The overall procedure can be used as part of a cleaning validation program in pharmaceutical manufacture of irinotecan hydrochloride.

  9. Development and validation of an HPLC method for the simultaneous determination of artesunate and mefloquine hydrochloride in fixed-dose combination tablets

    Directory of Open Access Journals (Sweden)

    Fernando Henrique Andrade Nogueira

    2013-12-01

    Full Text Available The present study developed and validated an HPLC method for the simultaneous determination of artesunate (AS and mefloquine hydrochloride (MQ in fixed-dose combination tablets, according to ICH guidelines. The chromatographic separation was carried out on an XBridge C18 (250 x 4.6 mm i.d., 5 µm particle size, Waters analytical column. The mobile phase included a 0.05 M monobasic potassium phosphate buffer (pH adjusted to 3.0 with phosphoric acid and acetonitrile (50 + 50, v/v. The flow rate was 1.0 mL/min, and the run time was 13 minutes. A dual-wavelength approach was employed: AS detection was performed at 210 nm and MQ was detected at 283 nm, using a diode array detector. Stability of sample solutions was evaluated for 8 hours after preparation, during which time the solutions remained stable. Youden's test was employed to evaluate robustness. The method proved to be linear (r²>0.99, precise (RSD<2.0%, accurate, selective, and robust, proving to be appropriate for routine drug quality control analysis.

  10. Pharmacognostic evaluation, and development and validation of a HPLC-DAD technique for gallocatechin and epigallocatechin in rhizomes from Limonium brasiliense

    Directory of Open Access Journals (Sweden)

    Andressa Blainski

    Full Text Available ABSTRACT Limonium brasiliense (Boiss. Kuntze, Plumbaginaceae, is a plant from the southern coast of Brazilian that is used for the treatment of premenstrual syndrome, menstrual disorders and genito-urinary infections. The aim of the present study was to determine the quality control parameters for rhizomes collected during different periods by pharmacopoeial and non-pharmacopoeial methods, and to develop and validate a HPLC-DAD method for quantitative control of marker substances. The measured parameters were: granulometric analysis (d50 = 0.21–0.48 mm, loss on drying (11.1–12.4%, total ash (4.9–5.7%, dry residue by extraction with acetone:water (7:3, v/v (30.6–39.5%, total polyphenol content (8.5–15.8%, and chromatographic fingerprint by HPLC and TLC. Besides, the acetone:water (7:3, v/v extraction solvent in combination with a turbo-extractor, yielded the crude extract with a significant increase in tannins (F4,20 = 37.0, p < 0.001. The antioxidant potential of the crude acetone:water (7:3, v/v extract, as well as the ethyl acetate and water fractions obtained after the partition process was evaluated by DPPH and the results were, respectively: IC50 6.87, 5.91, and 6.92 µg/ml. The validation parameters for the HPLC-DAD method showed adequate specificity, precision and accuracy. The gallo- and epigallocatechin contents were, respectively, 0.8–2.7% and 1.2–2.2%. These data contribute to analysis of the pharmacognostic quality control of the commonly used part from this species.

  11. Stability-indicating HPLC-DAD methods for determination of two binary mixtures: Rabeprazole sodium-mosapride citrate and rabeprazole sodium-itopride hydrochloride.

    Science.gov (United States)

    El-Fatatry, Hamed M; Mabrouk, Mokhtar M; Hewala, Ismail I; Emam, Ehab H

    2014-08-01

    Two selective stability-indicating HPLC methods are described for determination of rabeprazole sodium (RZ)-mosapride citrate (MR) and RZ-itopride hydrochloride (IO) mixtures in the presence of their ICH-stress formed degradation products. Separations were achieved on X-Bridge C18 column using two mobile phases: the first for RZ-MR mixture consisted of acetonitrile: 0.025 M KH 2 PO 4 solution: TEA (30:69:1 v/v; pH 7.0); the second for RZ-IO mixture was at ratio of 25:74:1 (v/v; pH 9.25). The detection wavelength was 283 nm. The two methods were validated and validation acceptance criteria were met in all cases. Peak purity testing using contrast angle theory, relative absorbance and log  A versus the wavelengths plots were presented. The % recoveries of the intact drugs were between 99.1% and 102.2% with RSD% values less than 1.6%. Application of the proposed HPLC methods indicated that the methods could be adopted to follow the stability of their formulations.

  12. Method validation and stability study of quercetin in topical emulsions

    Directory of Open Access Journals (Sweden)

    Rúbia Casagrande

    2009-01-01

    Full Text Available This study validated a high performance liquid chromatography (HPLC method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation limits were 18 and 29 ng/mL, respectively. The intra- and inter-assay precisions presented R.S.D. values lower than 2%. An average of 93% and 94% of quercetin was recovered for non-ionic and anionic emulsions, respectively. The raw material and anionic emulsion, but not non-ionic emulsion, were stable in all storage conditions for one year. The method reported is a fast and reliable HPLC technique useful for quercetin determination in topical emulsions.

  13. Development, Validation and Application of RP-HPLC Method: Simultaneous Determination of Antihistamine and Preservatives with Paracetamol in Liquid Formulations and Human Serum.

    Science.gov (United States)

    Hasan, Najmul; Chaiharn, Mathurot; Toor, Umair Ali; Mirani, Zulfiqar Ali; Sajjad, Ghulam; Sher, Nawab; Aziz, Mubashir; Siddiqui, Farhan Ahmed

    2016-01-01

    In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the mobile phase at flow rate 1.0 mL min(-1) using a Hibar(®) Lichrosorb(®) C18 column and monitored at wavelength of 230nm. The averages of absolute and relative recoveries were found to be 99.3%, 99.5%, 99.8% and 98.7% with correlation coefficient of 0.9977, 0.9998, 0.9984, and 0.9997 for cetirizine HCl, paracetamol, methylparaben and Propylparaben respectively. The limit of quantification and limit of detection were in range of 0.3 to 2.7 ng mL(-1) and 0.1 to 0.8 ng mL(-1) respectively. Under stress conditions of acidic, basic, oxidative, and thermal degradation, maximum degradation was observed in basic and oxidative stress where a significant impact was observed while all drugs were found almost stable in the other conditions. The developed method was validated in accordance with ICH and AOAC guidelines. The proposed method was successfully applied to quantify amount of paracetamol, cetirizine HCl and two most common microbial preservatives in bulk, dosage form and physiological fluid.

  14. Comparison of a specific HPLC determination of toxic aconite alkaloids in processed Radix aconiti with a titration method of total alkaloids.

    Science.gov (United States)

    Csupor, Dezso; Borcsa, Botond; Heydel, Barbara; Hohmann, Judit; Zupkó, István; Ma, Yan; Widowitz, Ute; Bauer, Rudolf

    2011-10-01

    In traditional Chinese medicine, Aconitum (Ranunculaceae) roots are only applied after processing. Nevertheless, several cases of poisoning by improperly processed aconite roots have been reported. The aim of this study was to develop a reliable analytical method to assess the amount of toxic aconite alkaloids in commercial aconite roots, and to compare this method with the commonly used total alkaloid content determination by titration. The content of mesaconitine, aconitine, and hypaconitine in 16 commercial samples of processed aconite roots was determined by an HPLC method and the total alkaloid content by indirect titration. Five samples were selected for in vivo toxicological investigation. In most of the commercial samples, toxic alkaloids were not detectable, or only traces were found. In four samples, we could detect >0.04% toxic aconite alkaloids, the highest with a content of 0.16%. The results of HPLC analysis were compared with the results obtained by titration, and no correlation was found between the two methods. The in vivo results reassured the validity of the HPLC determination. Samples with mesaconitine, aconitine, and hypaconitine content below the HPLC detection limit still contained up to 0.2% alkaloids determined by titration. Since titration of alkaloids gives no information selectively on the aconitine-type alkaloid content and toxicity of aconite roots this method is not appropriate for safety assessment. The HPLC method developed by us provides a quick and reliable assessment of toxicity and should be considered as a purity test in pharmacopoeia monographs.

  15. A simple micro-batch ion-exchange resin extraction method coupled with reverse-phase HPLC (MBRE-HPLC) to quantify lactoferrin in raw and heat-treated bovine milk.

    Science.gov (United States)

    Pochet, Sylvie; Arnould, Céline; Debournoux, Perrine; Flament, Jocelyne; Rolet-Répécaud, Odile; Beuvier, Eric

    2018-09-01

    Lactoferrin is an iron-binding cationic glycoprotein (pI = 8.7) beneficial for mammal health, especially udder and milk preservation. A new simple two-step method of quantification was developed. Lactoferrin in 1 mL of bovine skim milk was first adsorbed onto 100 mg of macroporous sulfonated-resin at pH 6.8 by rotary stirring for 90 min at 20-25 °C. After washing the resin, lactoferrin was desorbed using 1 mL of 2 M NaCl containing phenylalanine as a dilution marker, then fully resolved and quantified by RP-HPLC at 220 nm using a wide-bore C4 silica column. This robust, inexpensive and flexible method improves selectivity (no protein interference) and sensitivity compared to previous HPLC methods. In-laboratory validation demonstrated its linearity (25 to 514 µg Lf mL -1 ), accuracy (110 to 98% recovery), and precision (<4%), which were comparable to immuno-based methods. The results for individual raw cow's milk were strongly correlated with results using an ELISA test. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. A chromatographic method validation to quantify tablets Mephenesine of national production

    International Nuclear Information System (INIS)

    Suarez Perez, Yania; Izquierdo Castro, Adalberto; Milian Sanchez, Jana Daria

    2009-01-01

    Authors made validation of an analytical method by high performance liquid chromatography (HPLC) for quantification of Mephenesine in recently reformulated 500 mg tablets. With regard to its application to quality control, validation included the following parameters: linearity, accuracy, precision, and selectivity. Results were satisfactory within 50-150 % rank. In the case of its use in subsequent studies of chemical stability, the selectivity for stability and sensitivity was assessed. Estimated detection and quantification limits were appropriate, and the method was selective versus the possible degradation products. (Author)

  17. Optimization of extraction method and HPLC analysis of six caffeoylquinic acids in Pluchea indica leaves from different provenances in Thailand

    Directory of Open Access Journals (Sweden)

    Sumet Kongkiatpaiboon

    Full Text Available ABSTRACT Pluchea indica (L. Less., Asteraceae, is a medicinal plant which contains a high amount of phenolic compounds such as caffeoylquinic acid derivatives. The leaves have been traditionally used as a nerve tonic and extensively as herbal tea. This study aimed to develop and validate an HPLC method to quantitatively analyze six caffeoylquinic acid derivatives, viz. 3-O-caffeoylquinic acid, 4-O-caffeoylquinic acid, 5-O caffeoylquinic acid, 3,4-O-dicaffeoylquinic acid, 3,5-O-dicaffeoylquinic acid, and 4,5-O-dicaffeoylquinic acid in P. indica leaf extract. HPLC was carried out in a Hypersil BDS C18-column eluted with 0.5% acetic acid in water and methanol using gradient elution with a flow rate of 1 ml/min and detection at 326 nm. The method validation was performed to assure its linearity, precision, accuracy and limits of detection and quantitation. Several extraction techniques including maceration, decoction, digestion, Soxhlet extraction, and ultrasound extraction, were used to extract active constituents. The ultrasound extraction with 50% ethanol yielded the highest concentration of these caffeoylquinic acid derivatives in the P. indica leaf extract. Our developed HPLC method is simple and reliable for a routine analysis of the six caffeoylquinic acids in P. indica leaves and could potentially be applied to be used in commercial herbal products.

  18. A Simple and Validated Reverse Phase HPLC Methodfor the Determination of Rabeprazole inPharmaceutical Dosage Forms

    Directory of Open Access Journals (Sweden)

    Uma Mahesh Karra

    2010-01-01

    Full Text Available A simple and rapid reverse phase high performance liquid chromatography (RP-HPLC method was developed and validated for quantitative determination of rabeprazole in bulk drug samples and formulations. Rabeprazole was analyzed by using reverse phase LC-GC column (Inertsil ODS, 4.6 mm x 25 cm, 5 microns, with mobile phase consisting of methanol: water (78:22 v/v. The flow rate was set 1.0 mL/min and analysis was performed at wavelength 288 nm using Photo Diode Array (PDA detector at ambient temperature. The method was validated and stability studies were conducted under different conditions. The retention time for rabeprazole was around 4.12 minutes. The calibration curves were linear (r≥0.9998 over a concentration range from 20.0 to 80.0 μg/mL. Limit of detection (LOD and Limit of quantitation (LOQ were 8 ng/mL and 24 ng/mL respectively. The developed method was successfully applied to estimate the amount of rabeprazole in tablet formulations.

  19. Comparative study of fourteen alkaloids from Uncaria rhynchophylla hooks and leaves using HPLC-diode array detection-atmospheric pressure chemical ionization/MS method.

    Science.gov (United States)

    Qu, Jialin; Gong, Tianxing; Ma, Bin; Zhang, Lin; Kano, Yoshihiro; Yuan, Dan

    2012-01-01

    The purpose of the study is to compare alkaloid profile of Uncaria rhynchophylla hooks and leaves. Ten oxindole alkaloids and four glycosidic indole alkaloids were identified using HPLC-diode array detection (DAD) or LC-atmospheric pressure chemical ionization (APCI)-MS method, and a HPLC-UV method for simultaneous quantification of major alkaloids was validated. The hooks are characterized by high levels of four oxindole alkaloids rhynchophylline (R), isorhynchophylline (IR), corynoxeine (C) and isocorynoxeine (IC), while the leaves contained high level of two glycosidic indole alkaloids vincoside lactam (VL) and strictosidine (S). The presented methods have proven its usefulness in chemical characterization of U. rhynchophylla hooks and leaves.

  20. HPTLC Method Development and Validation of Zolpidem Tartrate in Bulk and Marketed Formulation

    OpenAIRE

    Abhay R. Shirode; Bharti G. Jadhav; Vilasrao J. Kadam

    2015-01-01

    High performance thin layer chromatography (HPTLC) offers many advantages over HPLC. It reduces the cost of analysis as compare to HPLC. The mobile phase consumption per sample is extremely low in HPTLC, hence reducing the acquisition and disposal cost. Considering the cost and suitability of analysis for estimation of zolpidem tartrate in bulk and its marketed formulation, HPTLC method was developed and validated. The Camag HPTLC system, employed with software winCATS (ver.1.4.1.8) was used ...

  1. Development and Validation of High Performance Liquid Chromatography Method for Determination Atorvastatin in Tablet

    Science.gov (United States)

    Yugatama, A.; Rohmani, S.; Dewangga, A.

    2018-03-01

    Atorvastatin is the primary choice for dyslipidemia treatment. Due to patent expiration of atorvastatin, the pharmaceutical industry makes copy of the drug. Therefore, the development methods for tablet quality tests involving atorvastatin concentration on tablets needs to be performed. The purpose of this research was to develop and validate the simple atorvastatin tablet analytical method by HPLC. HPLC system used in this experiment consisted of column Cosmosil C18 (150 x 4,6 mm, 5 µm) as the stationary reverse phase chomatography, a mixture of methanol-water at pH 3 (80:20 v/v) as the mobile phase, flow rate of 1 mL/min, and UV detector at wavelength of 245 nm. Validation methods were including: selectivity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The results of this study indicate that the developed method had good validation including selectivity, linearity, accuracy, precision, LOD, and LOQ for analysis of atorvastatin tablet content. LOD and LOQ were 0.2 and 0.7 ng/mL, and the linearity range were 20 - 120 ng/mL.

  2. A PLS-based extractive spectrophotometric method for simultaneous determination of carbamazepine and carbamazepine-10,11-epoxide in plasma and comparison with HPLC

    Science.gov (United States)

    Hemmateenejad, Bahram; Rezaei, Zahra; Khabnadideh, Soghra; Saffari, Maryam

    2007-11-01

    Carbamazepine (CBZ) undergoes enzyme biotransformation through epoxidation with the formation of its metabolite, carbamazepine-10,11-epoxide (CBZE). A simple chemometrics-assisted spectrophotometric method has been proposed for simultaneous determination of CBZ and CBZE in plasma. A liquid extraction procedure was operated to separate the analytes from plasma, and the UV absorbance spectra of the resultant solutions were subjected to partial least squares (PLS) regression. The optimum number of PLS latent variables was selected according to the PRESS values of leave-one-out cross-validation. A HPLC method was also employed for comparison. The respective mean recoveries for analysis of CBZ and CBZE in synthetic mixtures were 102.57 (±0.25)% and 103.00 (±0.09)% for PLS and 99.40 (±0.15)% and 102.20 (±0.02)%. The concentrations of CBZ and CBZE were also determined in five patients using the PLS and HPLC methods. The results showed that the data obtained by PLS were comparable with those obtained by HPLC method.

  3. Simultaneous Chloramphenicol and Florfenicol Determination by A Validated DLLME-HPLC-UV Method in Pasteurized Milk.

    Science.gov (United States)

    Karami-Osboo, Rouhollah; Miri, Ramin; Javidnia, Katayoun; Kobarfard, Farzad

    2016-01-01

    The antibiotic residues in milk are a well-known serious problem and pose several health hazards to consumers. We have described a simple, rapid, and inexpensive DLLME-HPLC/UV technique for the extraction of chloramphenicol and florfenicol residues in milk samples. Under the optimum conditions, linearity of the method was observed over the range 0.02-0.85 µg/L with correlation coefficients > 0.999. The proposed method has been found to have a good limit of detection (signal to noise ratio = 3) for chloramphenicol (12.5 µg/Kg) and florfenicol (12.2 µg/Kg), and precision with relative standard deviation values under 15% (RSD, n = 3). Good recoveries (69.1-79.4%) were obtained for the extraction of the target analytes in milk samples. This simple and economic method has been applied for analyses of 15 real milk samples. Among all samples only one of them was contaminated to florfenicol; 62.4 µg/Kg and contamination to chloramphenicol was not detected.

  4. Development and validation of an HPLC/UV/MS method for simultaneous determination of 18 preservatives in grapefruit seed extract.

    Science.gov (United States)

    Ganzera, Markus; Aberham, Anita; Stuppner, Hermann

    2006-05-31

    Grapefruit seed extracts are used in cosmetics, food supplements, and pesticides because of their antimicrobial properties, but suspicions about the true nature of the active compounds arose when synthetic disinfectants such as benzethonium or benzalkonium chloride were found in commercial products. The HPLC method presented herein allows the quality assessment (qualitative and quantitative) of these products for the first time. On the basis of a standard mixture of 18 preservatives most relevant for food and grapefruit products, a method was developed allowing the baseline separation of all compounds within 40 min. Optimum results were obtained with a C-8 stationary phase and a solvent system comprising aqueous trifluoroacetic acid, acetonitrile, and 2-propanol. The assay was fully validated and shown to be sensitive (LOD or = 96.1%), repeatable (sigma(rel) < or = 3.5%), precise (intra-day variation < or = 4.5%, interday variation < or = 4.1%), and rugged. Without any modifications the method could be adopted for LC-MS experiments, where the compounds of interest were directly assignable in positive ESI mode. The quantitative results of several products for ecofarming confirmed previous studies, as seven out of nine specimens were adulterated with preservatives in varying composition. The samples either contained benzethonium chloride (2.5-176.9 mg/mL) or benzalkonium chloride (138.2-236.3 mg/mL), together with smaller amounts of 4-hydroxybenzoic acid esters, benzoic acid, and salicylic acid.

  5. [Application of HPLC-UV method for aripiprazole determination in serum].

    Science.gov (United States)

    Synowiec, Anna; Gomółka, Ewa; Zyss, Tomasz; Zieba, Andrzej; Florek, Ewa; Piekoszewski, Wojciech

    2012-01-01

    Aripiprazole is a new drug applied in schizophrenia treatment. There are not strict indications for aripiprazole therapeutic drug monitoring. Despite, serum aripiprazole measuring would help control the drug doses effectiveness. The drug monitoring can eliminate overdosing, adverse effects and let control proper drug ingestion. The aim of the paper was to develop a simple method for aripiprazole determination in serum for therapeutic drug monitoring. High performance liquid chromatography with spectrophotometric detection (HPLC-UV) was used. Resolution was performed on LC-8 column; moving phase was solution 0,025M trimethylammonium buffer: acetonitrile (62:38). Isocratic flow was 1,2 ml/min; internal standard (IS) was promazine; monitored wavelength was lambda=214 nm. The validation parameters were: limits of linearity (LOL) 100-800 ng/ml, limit of detection (LOD) 10 ng/ml, limit of quantity (LOQ) 100 ng/ml. Coefficient of variation (CV) describing accuracy and precision didn't cross 10%. The method was useful for therapeutic drug monitoring in serum of patients treated with aripiprazole.

  6. Methods and applications of HPLC-AMS (WBio 5)

    International Nuclear Information System (INIS)

    Bucholz, B A; Clifford, A J; Duecker, S R; Lin, Y; Vogel, J S

    1999-01-01

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a(sup 14)C-labelled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the(sup 14)C content above the control predose tissue and converting to equivalents of the parent compound. High Performance Liquid Chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement. Unknowns are identified by coelution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the(sup 14)C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of(sup 14)C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected(sup 14)C activity and lt;0.17 Bq (4.5 pCi) on the HPLC column

  7. Dissolution profiles of perindopril and indapamide in their fixed-dose formulations by a new HPLC method and different mathematical approaches

    Directory of Open Access Journals (Sweden)

    Gumieniczek Anna

    2015-09-01

    Full Text Available A new HPLC method was introduced and validated for simultaneous determination of perindopril and indapamide. Validation procedure included specificity, sensitivity, robustness, stability, linearity, precision and accuracy. The method was used for the dissolution test of perindopril and indapamide in three fixed-dose formulations. The dissolution procedure was optimized using different media, different pH of the buffer, surfactants, paddle speed and temperature. Similarity of dissolution profiles was estimated using different model-independent and model-dependent methods and, additionally, by principal component analysis (PCA. Also, some kinetic models were checked for dissolved amounts of drugs as a function of time.

  8. Simplified RP-HPLC method for multi-residue analysis of abamectin, emamectin benzoate and ivermectin in rice.

    Science.gov (United States)

    Xie, Xianchuan; Gong, Shu; Wang, Xiaorong; Wu, Yinxing; Zhao, Li

    2011-01-01

    A rapid, reliable and sensitive reverse-phase high-performance liquid chromatography method with fluorescence detection (RP-FLD-HPLC) was developed and validated for simultaneous analysis of the abamectin (ABA), emamectin (EMA) benzoate and ivermectin (IVM) residues in rice. After extraction with acetonitrile/water (2 : 1) with sonication, the avermectin (AVMs) residues were directly derivatised by N-methylimidazole (N-NMIM) and trifluoroacetic anhydride (TFAA) and then analysed on RP-FLD-HPLC. A good linear relationship (r(2 )> 0.99) was obtained for three AVMs ranging from 0.01 to 5 microg ml(-1), i.e. 0.01-5.0 microg g(-1) in rice matrix. The limit of detection (LOD) and the limit of quantification (LOQ) were between 0.001 and 0.002 microg g(-1) and between 0.004 and 0.006 microg g(-1), respectively. Recoveries were from 81.9% to 105.4% and precision less than 12.4%. The proposed method was successfully applied to routine analysis of the AVMs residues in rice.

  9. Development and Validation of HPLC Method for the Simultaneous Determination of Five Food Additives and Caffeine in Soft Drinks

    Directory of Open Access Journals (Sweden)

    Bürge Aşçı

    2016-01-01

    Full Text Available Box-Behnken design was applied to optimize high performance liquid chromatography (HPLC conditions for the simultaneous determination of potassium sorbate, sodium benzoate, carmoisine, allura red, ponceau 4R, and caffeine in commercial soft drinks. The experimental variables chosen were pH (6.0–7.0, flow rate (1.0–1.4 mL/min, and mobile phase ratio (85–95% acetate buffer. Resolution values of all peak pairs were used as a response. Stationary phase was Inertsil OctaDecylSilane- (ODS- 3V reverse phase column (250 × 4.6 mm, 5 μm dimensions. The detection was performed at 230 nm. Optimal values were found 6.0 pH, 1.0 mL/min flow rate, and 95% mobile phase ratio for the method which was validated by calculating the linearity (r2>0.9962, accuracy (recoveries ≥ 95.75%, precision (intraday variation ≤ 1.923%, interday variation ≤ 1.950%, limits of detection (LODs, and limits of quantification (LOQs parameters. LODs and LOQs for analytes were in the range of 0.10–0.19 μg/mL and 0.33–0.63 μg/mL, respectively. The proposed method was applied successfully for the simultaneous determination of the mixtures of five food additives and caffeine in soft drinks.

  10. Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies

    Directory of Open Access Journals (Sweden)

    Bo Wei

    2008-01-01

    Full Text Available A simple, specific, sensitive, and rapid high performance liquid chromatography (HPLC method for the determination of griseofulvin in small volumes of rat plasma was developed and validated using warfarin as an internal standard. Biological sample preparation involved simple extraction with acetonitrile, followed by dilution with aqueous mobile phase buffer (20 mM sodium dihydrogen phosphate, pH 3.5 to eliminate any chromatographic solvent effects. Griseofulvin and warfarin were baseline separated and quantitated on a C 18 reversed phase column (4.6 x 150 mm, 3.5 µm, using a mobile phase composed of a 20 mM aqueous solution of sodium dihydrogen phosphate-acetonitrile (55:45, v/v, pH 3.5 delivered at a flow rate of 1.0 mL/min, and with fluorescence detection (λ excitation = 300 nm, λ emission = 418 nm. The method was proven to be linear over a plasma griseofulvin concentration range of 10 to 2500 ng/mL with a mean correlation coefficient of 0.9996. The intra-day and inter-day accuracy (relative error were in the range of 0.89% to 9.26% and 0.71% to 7.68%, respectively. The within-day precision (coefficient of variation was less than 3.0% and the between-day precision was less than 7.5%. The mean recovery of griseofulvin from rat plasma was found to be 99.2%. The limit of detection (LOD and the limit of quantification (LOQ of griseofulvin were determined to be 1 ng/mL and 10 ng/mL, respectively. The developed method was successfully applied to quantitatively assess the pharmacokinetics of griseofulvin in rats following a single 50 mg/kg oral dose of the drug.

  11. Computer-aided method for identification of major flavone/flavonol glycosides by high-performance liquid chromatography-diode array detection-tandem mass spectrometry (HPLC-DAD-MS/MS).

    Science.gov (United States)

    Wang, Zhengfang; Lin, Longze; Harnly, James M; Harrington, Peter de B; Chen, Pei

    2014-11-01

    A new computational tool is proposed here for tentatively identifying major (UV quantifiable) flavone/flavonol glycoside peaks of high performance liquid chromatogram (HPLC)-diode array detection (DAD)-tandem mass spectrometry (MS/MS) profiles based on a MATLAB-based script implementing an in-house algorithm. The HPLC-DAD-MS/MS profiles of red onion, Chinese lettuce, carrot leaf, and celery seed extracts were analyzed by the proposed computer-aided screening method for identifying possible flavone/flavonol glycoside peaks from the HPLC-UV and MS total ion current (TIC) chromatograms. The number of identified flavone/flavonol glycoside peaks of the HPLC-UV chromatograms is four, four, six, and nine for red onion, Chinese lettuce, carrot leaf, and celery seed, respectively. These results have been validated by human(s) experts. For the batch processing of nine HPLC-DAD-MS/MS profiles of celery seed extract, the entire script execution time was within 15 s while manual calculation of only one HPLC-DAD-MS/MS profile by a flavonoid expert could take hours. Therefore, this MATLAB-based screening method is able to facilitate the HPLC-DAD-MS/MS analysis of flavone/flavonol glycosides in plants to a large extent.

  12. A Simple, Fast, Low Cost, HPLC/UV Validated Method for Determination of Flutamide: Application to Protein Binding Studies.

    Science.gov (United States)

    Esmaeilzadeh, Sara; Valizadeh, Hadi; Zakeri-Milani, Parvin

    2016-06-01

    The main goal of this study was development of a reverse phase high performance liquid chromatography (RP-HPLC) method for flutamide quantitation which is applicable to protein binding studies. Ultrafilteration method was used for protein binding study of flutamide. For sample analysis, flutamide was extracted by a simple and low cost extraction method using diethyl ether and then was determined by HPLC/UV. Acetanilide was used as an internal standard. The chromatographic system consisted of a reversed-phase C8 column with C8 pre-column, and the mobile phase of a mixture of 29% (v/v) methanol, 38% (v/v) acetonitrile and 33% (v/v) potassium dihydrogen phosphate buffer (50 mM) with pH adjusted to 3.2. Acetanilide and flutamide were eluted at 1.8 and 2.9 min, respectively. The linearity of method was confirmed in the range of 62.5-16000 ng/ml (r(2) > 0.99). The limit of quantification was shown to be 62.5 ng/ml. Precision and accuracy ranges found to be (0.2-1.4%, 90-105%) and (0.2-5.3 %, 86.7-98.5 %) respectively. Acetanilide and flutamide capacity factor values of 1.35 and 2.87, tailing factor values of 1.24 and 1.07 and resolution values of 1.8 and 3.22 were obtained in accordance with ICH guidelines. Based on the obtained results a rapid, precise, accurate, sensitive and cost-effective analysis procedure was proposed for quantitative determination of flutamide.

  13. Principles of Developing Multi-Pesticide Methods Based on HPLC Determination

    Energy Technology Data Exchange (ETDEWEB)

    Dudar, E. [Plant Protection & Soil Conservation Service of Budapest, Budapest (Hungary)

    2009-07-15

    Principles for the development of multi-pesticide methods based on HPLC determination are outlined. Flow charts and block diagrams give guidance on how to proceed stepwise in the set-up of respective analytical methods. Detailed information is provided on what to take into consideration for setting up a pesticide formulation analysis method. HPLC variables like the types of column, solvents and their strength, pH value, eluent modifiers, column temperature, etc, and the influence on the separation and resolution of chromatographic peaks are discussed as well as the necessity and benefits of internal standardization. Examples of system suitability testing experiments are given for illustration. (author)

  14. Determination of flutamide and two major metabolites using HPLC-DAD and HPTLC methods.

    Science.gov (United States)

    Abdelwahab, Nada S; Elshemy, Heba A H; Farid, Nehal F

    2018-01-25

    Flutamide is a potential antineoplastic drug classified as an anti-androgen. It is a therapy for men with advanced prostate cancer, administered orally after which it undergoes extensively first pass metabolism in the liver with the production of several metabolites. These metabolites are predominantly excreted in urine. One of the important metabolites in plasma is 4-nitro-3-(trifluoromethyl)phenylamine (Flu-1), while the main metabolite in urine is 2-amino-5-nitro-4-(trifluoromethyl)phenol (Flu-3). In this work the two metabolites, Flu-1 and Flu-3, have been synthesized, and then structural confirmation has been carried out by HNMR analysis. Efforts were exerted to develop chromatographic methods for resolving Flutamide and its metabolites with the use of acceptable solvents without affecting the efficiency of the methods. The drug along with its metabolites were quantitatively analyzed in pure form, human urine, and plasma samples using two chromatographic methods, HPTLC and HPLC-DAD methods. FDA guidelines for bio-analytical method validation were followed and USP recommendations were used for analytical method validation. Interference from excipients has been tested by application of the methods to pharmaceutical tablets. No significant difference was found between the proposed methods and the official one when they were statistically compared at p value of 0.05%.

  15. A Simple HPLC Bioanalytical Method for the Determination of ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, accurate, and precise high performance chromatography (HPLC) method with spectrophotometric detection for the determination of doxorubicin hydrochloride in rat plasma. Methods: Doxorubicin hydrochloride and daunorubicin hydrochloride (internal standard, IS) were separated on a C18 ...

  16. Development and Validation of a Stability-Indicating RP-HPLC Method for Rapid Determination of Doxycycline in Pharmaceutical Bulk and Dosage Forms

    Directory of Open Access Journals (Sweden)

    Shabnam Pourmoslemi, Soroush Mirfakhraee, Saeid Yaripour, Ali Mohammadi

    2016-06-01

    Full Text Available Background: A rapid stability-indicating RP-HPLC method for analysis of doxycycline in the presence of its degradation products was developed and validated. Methods: Forced degradation studies were carried out on bulk samples and capsule dosage forms of doxycycline using acid, base, H2O2, heat, and UV light as described by ICH for stress conditions to demonstrate the stability-indicating power of the method. Separations were performed on a Perfectsil® Target ODS column (3-5µm, 125 mm×4 mm, using a mobile phase consisting of methanol-50 mM ammonium acetate buffer (containing 0.1% v/v trifluoroacetic acid and 0.1% v/v triethylamine, pH 2.5 (50:50 v/v at room temperature. The flow rate was 0.8 mL/min. Results: The method linearity was investigated in the range of 25–500 µg/mL (r > 0.9999. The LOD and LOQ were 5 and 25 µg/mL, respectively. The method selectivity was evaluated by peak purity test using a diode array detector. There was no interference among detection of doxycycline and its stressed degradation products. Total peak purity numbers were in the range of 0.94-0.99, indicating the homogeneity of DOX peaks. Conclusion: These data show the stability-indicating nature of the method for quality control of doxycycline in bulk samples and capsule dosage forms.

  17. Validation of quantitative method for azoxystrobin residues in green beans and peas.

    Science.gov (United States)

    Abdelraheem, Ehab M H; Hassan, Sayed M; Arief, Mohamed M H; Mohammad, Somaia G

    2015-09-01

    This study presents a method validation for extraction and quantitative analysis of azoxystrobin residues in green beans and peas using HPLC-UV and the results confirmed by GC-MS. The employed method involved initial extraction with acetonitrile after the addition of salts (magnesium sulfate and sodium chloride), followed by a cleanup step by activated neutral carbon. Validation parameters; linearity, matrix effect, LOQ, specificity, trueness and repeatability precision were attained. The spiking levels for the trueness and the precision experiments were (0.1, 0.5, 3 mg/kg). For HPLC-UV analysis, mean recoveries ranged between 83.69% to 91.58% and 81.99% to 107.85% for green beans and peas, respectively. For GC-MS analysis, mean recoveries ranged from 76.29% to 94.56% and 80.77% to 100.91% for green beans and peas, respectively. According to these results, the method has been proven to be efficient for extraction and determination of azoxystrobin residues in green beans and peas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Environmentally evaluated HPLC-ELSD method to monitor enzymatic synthesis of a non-ionic surfactant.

    Science.gov (United States)

    Gaber, Yasser; Akerman, Cecilia Orellana; Hatti-Kaul, Rajni

    2014-01-01

    N-Lauroyl-N-methylglucamide is a biodegradable surfactant derived from renewable resources. In an earlier study, we presented an enzymatic solvent-free method for synthesis of this compound. In the present report, the HPLC method developed to follow the reaction between lauric acid/methyl laurate and N-methyl glucamine (MEG) and its environmental assessment are described. Use of ultraviolet (UV) absorption or refractive index (RI) detectors did not allow the detection of N-methyl glucamine (MEG). With Evaporative light scattering detector ELSD, it was possible to apply a gradient elution, and detect MEG with a limit of detection, LOD = 0.12 μg. A good separation of the peaks: MEG, lauric acid, product (amide) and by-product (amide-ester) was achieved with the gradient program with a run time of 40 min. The setting of ELSD detector was optimized using methyl laurate as the analyte. LC-MS/MS was used to confirm the amide and amide-ester peaks. We evaluated the greenness of the developed method using the freely available software HPLC-Environmental Assessment Tool (HPLC-EAT) and the method got a scoring of 73 HPLC-EAT units, implying that the analytical procedure was more environmentally benign compared to some other methods reported in literature whose HPLC-EAT values scored up to 182. Use of ELSD detector allowed the detection and quantification of the substrates and the reaction products of enzymatic synthesis of the surfactant, N-lauroyl-N-methylglucamide. The developed HPLC method has acceptable environmental profile based on HPLC-EAT evaluation.

  19. Rapid HPLC-MS method for the simultaneous determination of tea catechins and folates.

    Science.gov (United States)

    Araya-Farias, Monica; Gaudreau, Alain; Rozoy, Elodie; Bazinet, Laurent

    2014-05-14

    An effective and rapid HPLC-MS method for the simultaneous separation of the eight most abundant tea catechins, gallic acid, and caffeine was developed. These compounds were rapidly separated within 9 min by a linear gradient elution using a Zorbax SB-C18 packed with sub 2 μm particles. This methodology did not require preparative and semipreparative HPLC steps. In fact, diluted tea samples can be easily analyzed using HPLC-MS as described in this study. The use of mass spectrometry detection for quantification of catechins ensured a higher specificity of the method. The percent relative standard deviation was generally lower than 4 and 7% for most of the compounds tested in tea drinks and tea extracts, respectively. Furthermore, the method provided excellent resolution for folate determination alone or in combination with catechins. To date, no HPLC method able to discriminate catechins and folates in a quick analysis has been reported in the literature.

  20. Determination of Anthracycline Drug Residual in Cleaning Validation Swabs of Stainless-Steel Equipment after Production of Cytostatic Injections Using HPLC Analytical Method

    Directory of Open Access Journals (Sweden)

    Zuzana Slivová

    2015-01-01

    Full Text Available Standard cleaning procedures of production line equipment were verified after manufacture of cytostatic injections containing Anthracycline derivate substance. Residual content of Anthracycline drug substance on stainless-steel equipment surface was determined using swab sampling with a specific HPLC-DAD analysis. The acceptance limit was decided as 200.0 μg/100 cm2. Recovery from the stainless-steel surface was 90.1%. Linearity of the method was observed in the concentration range of 0.155–194 μg/mL when estimated using Zorbax TMS (5 μm, 0.25 m × 4.6 mm ID column at 1.3 mL/min flow rate and 254 nm (DAD 190–600 nm. The mobile phase consisted of lauryl hydrogen sulphate solution (3.7 g/L : methanol : acetonitrile (54 : 16 : 30, v/v/v with pH adjusted to 2.5 using phosphoric acid (85%. The LOD and LOQ for Anthracycline derivate were found to be 0.047 and 0.155 μg/mL, respectively. The method validation confirmed the method provides acceptable degree of selectivity, linearity, accuracy, and precision for the intended purposes.

  1. Validated method for the analysis of goji berry, a rich source of zeaxanthin dipalmitate.

    Science.gov (United States)

    Karioti, Anastasia; Bergonzi, Maria Camilla; Vincieri, Franco F; Bilia, Anna Rita

    2014-12-31

    In the present study an HPLC-DAD method was developed for the determination of the main carotenoid, zeaxanthin dipalmitate, in the fruits of Lycium barbarum. The aim was to develop and optimize an extraction protocol to allow fast, exhaustive, and repeatable extraction, suitable for labile carotenoid content. Use of liquid N2 allowed the grinding of the fruit. A step of ultrasonication with water removed efficiently the polysaccharides and enabled the exhaustive extraction of carotenoids by hexane/acetone 50:50. The assay was fast and simple and permitted the quality control of a large number of commercial samples including fruits, juices, and a jam. The HPLC method was validated according to ICH guidelines and satisfied the requirements. Finally, the overall method was validated for precision (% RSD ranging between 3.81 and 4.13) and accuracy at three concentration levels. The recovery was between 94 and 107% with RSD values <2%, within the acceptable limits, especially if the difficulty of the matrix is taken into consideration.

  2. Development and validation of RP-HPLC-UV/ Vis method for determination of phenolic compounds in several personal care products

    International Nuclear Information System (INIS)

    Mohammed Akkbik; Zaini Asim; Fasihuddin Ahmad

    2011-01-01

    A HPLC method with ultraviolet-visible spectrophotometry detection has been optimized and validated for the simultaneous determination of phenolic compounds, such as butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) as antioxidants, and octyl methyl cinnamate (OMC) as UVB-filter in several personal care products. The dynamic range was between 1 to 250 mg/ L with relative standard deviation less than 0.25 %, (n=4). Limit of detection for BHA, BHT and OMC were 0.196, 0.170 and 0.478 mg/ L, respectively. While limit of quantification for BHA, BHT and OMC were 0.593, 0.515 and 1.448 mg/ L, respectively. The recovery for BHA, BHT and OMC ranged from 92.1-105.9 %, 83.2-108.9 % and 87.3-103.7 %, respectively. The concentration ranges of BHA, BHT and OMC in 12 commercial personal care samples were 0.13-4.85, 0.16-2.30 and 0.12-65.5 mg/ g, respectively. The concentrations of phenolic compounds in these personal care samples were below than maximum allowable concentration in personal care formulation for example 0.0004 - 10 mg/ g, 0.002 - 5 mg/ g and up to 100 mg/ g for BHA, BHT and OMC, respectively. (author)

  3. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    Science.gov (United States)

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  4. A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2010-01-01

    Full Text Available This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 μL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm, 5 μ, The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N hydrochloric acid, base (1.0 N sodium hydroxide, oxidation (30% hydrogen peroxide, thermal (105 ° C, photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%, linearity (linearity of range about 70-130 μg/mL, ruggedness (Overall % RSD about 0.35%, stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min. and robustness.

  5. A Validated Stability-indicating Reverse Phase HPLC Assay Method for the Determination of Memantine Hydrochloride Drug Substance with UV-Detection Using Precolumn Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Bhavil Narola

    2010-07-01

    Full Text Available This present paper deals with the development and validation of a stability indicating high performance liquid chromatographic method for the quantitative determination of Memantine hydrochloride. Memantine hydrochloride was derivatized with 0.015 M 9-fluorenylmethyl chloroformate (FMOC and 0.5 M borate buffer solution by keeping it at room temperature for about 20 minutes and the chromatographic separation achieved by injecting 10 µL of the derivatized mixture into a Waters HPLC system with photodiode array detector using a kromasil C18 column (150 × 4.6 mm, 5 µ. The mobile phase consisting of 80% acetonitrile and 20% phosphate buffer solution and a flow rate of 2 milliliter/minute. The Memantine was eluted at approximately 7.5 minutes. The volume of FMOC used in derivatization, concentration of FMOC and derivatization time was optimized and used. Forced degradation studies were performed on bulk sample of Memantine hydrochloride using acid (5.0 Normal (N hydrochloric acid, base (1.0 N sodium hydroxide, oxidation (30% hydrogen peroxide, thermal (105°C, photolytic and humidity conditions. The developed LC method was validated with respect to specificity, precision (% RSD about 0.70%, linearity (linearity of range about 70–130 µg/mL, ruggedness (Overall % RSD about 0.35%, stability in analytical solution (Cumulative % RSD about 0.11% after 1450 min. and robustness.

  6. New Stability Indicating RP-HPLC Method for the Estimation of Cefpirome Sulphate in Bulk and Pharmaceutical Dosage Forms.

    Science.gov (United States)

    Rao, Kareti Srinivasa; Kumar, Keshar Nargesh; Joydeep, Datta

    2011-01-01

    A simple stability indicating reversed-phase HPLC method was developed and subsequently validated for estimation of Cefpirome sulphate (CPS) present in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a LiChroCART-Lichrosphere100, C18 RP column (250 mm × 4mm × 5 μm) in an isocratic separation mode with mobile phase consisting of methanol and water in the proportion of 50:50 % (v/v), at a flow rate 1ml/min, and the effluent was monitored at 270 nm. The retention time of CPS was 2.733 min and its formulation was exposed to acidic, alkaline, photolytic, thermal and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. The described method was linear over a range of 0.5-200μg/ml. The percentage recovery was 99.46. F-test and t-test at 95% confidence level were used to check the intermediate precision data obtained under different experimental setups; the calculated value was found to be less than the critical value.

  7. Qualitative and quantitative determination of yohimbine in authentic yohimbe bark and in commercial aphrodisiacs by HPLC-UV-API/ MS methods.

    Science.gov (United States)

    Zanolari, Boris; Ndjoko, Karine; Ioset, Jean-Robert; Marston, Andrew; Hostettmann, Kurt

    2003-01-01

    The development and validation of a rapid qualitative and quantitative method based on an HPLC-UV-MS technique with atmospheric pressure chemical ionisation and electrospray ionisation for the analysis of yohimbine in a number of commercial aphrodisiac products is reported. HPLC with multiple-stage mass spectrometry experiments allowed the identification of the target compound and increased the selectivity of complex analyses such as those involved with multi-botanical preparations. The precision and the robustness of the method were improved by the use of two internal standards: codeine for UV detection and deuterium-labelled yohimbine for MS detection. Twenty commercial aphrodisiac preparations were analysed and the amount of yohimbine measured and expressed as the maximal dose per day suggested on product labels ranged from 1.32 to 23.16 mg.

  8. RP-HPLC Method for the Estimation of Nebivolol in Tablet Dosage Form

    Directory of Open Access Journals (Sweden)

    M. K. Sahoo

    2009-01-01

    Full Text Available A reverse phase HPLC method is described for the determination of nebivolol in tablet dosage form. Chromatography was carried on a Hypersil ODS C18 column using a mixture of methanol and water (80:20 v/v as the mobile phase at a flow rate of 1.0 mL/min with detection at 282 nm. Chlorzoxazone was used as the internal standard. The retention times were 3.175 min and 4.158 min for nebivolol and chlorzoxazone respectively. The detector response was linear in the concentration of 1-400 μg/mL. The limit of detection and limit of quantification was 0.0779 and 0.2361 μg/mL respectively. The percentage assay of nebivolol was 99.974%. The method was validated by determining its sensitivity, accuracy and precision. The proposed method is simple, fast, accurate and precise and hence can be applied for routine quality control of nebivolol in bulk and tablet dosage form.

  9. Development and validation of a HPLC-MS/MS method for the determination of phytolaccagenin in rat plasma and application to a pharmacokinetic study.

    Science.gov (United States)

    Wei, Fenghuan; Singh, Ravi Shankar Prasad; Fueth, Matthias; Swarts, Steven; Okunieff, Paul; Derendorf, Hartmut

    2015-03-25

    Radix Phytolaccae (the dried root of Phytolacca acinosa Roxb. or Phytolacca americana L.) is widely used in East Asian countries for the treatment of inflammation-related diseases. The active component of Radix Phtolaccae is Phytolcaccagenin a triterpenoid saponin. Phytolcaccagenin has anti-inflammatory activities that exceed those of Esculentoside A and its derivatives regarding suppression of LPS-induced inflammation, and has a lower toxicity profile with less hemolysis. To date, no information is available about analytical method and pharmacokinetic studies of phytolaccagenin. To explore PK profile of this compound, a HPLC-MS/MS assay of phytolaccagenin in rat plasma was developed and validated. The method was fully validated according to FDA Guidance for industry. The detection was performed by a triple-quadrupole tandem mass spectrometer with multiple reactions monitoring (MRM) in positive ion mode via electrospray ionization. The monitored transitions were m/z 533.2>515.3 for Phytolcaccagenin, and 491.2>473.2 for I.S. The analysis was performed on a Symmetry C18 column (4.6 mm × 50 mm, 3.5 μm) using gradient elution with the mobile phase consisting of acetonitrile and 0.1% formic acid water at a flow rate of 1 ml/min with a 1:1 splitter ratio. The method was validated with a LLOQ of 20 ng/ml and an ULOQ of 1000 ng/ml. The response versus concentration data were fitted with 1/x weighting and the correlation coefficient (r) were greater than 0.999. The average matrix effect and the average extraction recovery were acceptable. This validation in rat plasma demonstrated that phytolaccagenin was stable for 30 days when stored below -20°C, for 6h at room temperature (RT, 22°C), for 12 h at RT for prepared control samples in auto-sampler vials, and during three successive freeze/thaw cycles results at -20°C. The validated method has been successfully applied to an intravenous bolus pharmacokinetic study of phytolaccagenin in male Sprague-Dawley rats (10 mg

  10. Development and validation of methodology for technetium-99m radiopharmaceuticals using high performance liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Almeida, Erika Vieira de

    2009-01-01

    Radiopharmaceuticals are compounds, with no pharmacological action, which have a radioisotope in their composition and are used in Nuclear Medicine for diagnosis and therapy of several diseases. In this work, the development and validation of an analytical method for 99 mTc-HSA, 99 mTc-EC, 99 mTc-ECD and 99 mTc-Sestamibi radiopharmaceuticals and for some raw materials were carried out by high performance liquid chromatography (HPLC). The analyses were performed in a Shimadzu HPLC equipment, LC-20AT Prominence model. Some impurities were identified by the addition of a reference standard substance. Validation of the method was carried out according to the criteria defined in RE n. 899/2003 of the National Sanitary Agency (ANVISA). The results for robustness of the method showed that it is necessary to control flow rate conditions, sample volume, pH of the mobile phase and temperature of the oven. The analytical curves were linear in the concentration ranges, with linear correlation coefficients (r 2 ) above 0.9995. The results for precision, accuracy and recovery showed values in the range of 0.07-4.78%, 95.38-106.50% and 94.40-100.95%, respectively. The detection limits and quantification limits varied from 0.27 to 5.77 μg mL -1 and 0.90 to 19.23 μg mL -1 , respectively. The values for HAS, EC, ECD and MIBI in the lyophilized reagents were 8.95; 0.485; 0.986 and 0.974 mg L-1, respectively. The mean radiochemical purity for 99 mTc-HSA, 99 mTc-EC, 99 mTc-ECD and 99 mTc-Sestamibi was (97.28 ± 0.09)%, (98.96 ± 0.03)%, (98.96 ± 0.03)% and (98.07 ± 0.01)%, respectively. All the parameters recommended by ANVISA were evaluated and the results are below the established limits. (author)

  11. Determination of Trace Elements in Uranium by HPLC-ID-ICP-MS: NTNFC Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Manard, Benjamin Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wylie, Ernest Miller II [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Xu, Ning [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tandon, Lav [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-10-19

    This report covers the FY 16 effort for the HPLC-ID-ICP-MS methodology 1) sub-method validation for the group I&II elements, 2) sub-method stood-up and validation for REE, 3) sub-method development for the transition element, and 4) completion of a comprehensive SOP for three families of elements.

  12. Stability-Indicating RP-HPLC Method for Determination of Guanfacine Hydrochloride in Bulk Drugs and in Pharmaceutical Dosage Form

    Directory of Open Access Journals (Sweden)

    Vinod K. Ahirrao

    2011-04-01

    Full Text Available A novel stability-indicating RP-HPLC method was developed and validated for quantitative determination of guanfacine hydrochloride in bulk drug and in pharmaceutical dosage form. An isocratic, reversed phase HPLC method was developed to separate the drug from the degradation products, using Apollo, C18 (250mm x 4.6mm, 5µm column with mobile phase of 50mM Ammonium acetate (volatile buffer and acetonitrile (65:35, v/v. UV detection has been done at wavelength 220 nm. The guanfacine hydrochloride was subjected to the stress conditions of hydrolysis (acid, base, oxidation, photolysis and thermal degradation. The stressed samples were analyzed by the proposed method. The analyte peak shape was excellent. The described method shows excellent linearity over a range of 30 – 450 µg/mL. The correlation coefficient for guanfacine hydrochloride was 0.999. The limit of detection for Guanfacine hydrochloride is 0.011 µg/mL and the limit of quantification is 0.038 µg/mL respectively.Degradation was observed for guanfacine hydrochloride in base, thermal and in 30% H2O2 conditions. The drug was found to be stable in the other stress conditions attempted. The degradation products were well resolved from main peak. The percentage recovery of guanfacine hydrochloride was ranged from (99.2% to 100.5% in pharmaceutical dosage form. The developed method was validated with respect to the linearity, accuracy (recovery, precision, specificity and robustness. The forced degradation studies prove the stability indicating power of the method.

  13. Development and validation of a rapid reversed-phase HPLC method for the determination of the non-nucleoside reverse transcriptase inhibitor dapivirine from polymeric nanoparticles.

    Science.gov (United States)

    das Neves, José; Sarmento, Bruno; Amiji, Mansoor M; Bahia, Maria Fernanda

    2010-06-05

    The objective of this work was to develop and validate a rapid reversed-phase (RP) high-performance liquid chromatography (HPLC) method for the in vitro pharmaceutical characterization of dapivirine-loaded polymeric nanoparticles. Chromatographic runs were performed on a RP C18 column with a mobile phase comprising acetonitrile-0.5% (w/v) triethanolamine solution in isocratic mode (80:20, v/v) at a flow rate of 1 ml/min. Dapivirine was detected at a wavelength of 290 nm. The method was shown to be specific, linear in the range of 1-50 microg/ml (R(2)=0.9998), precise at the intra-day and inter-day levels as reflected by the relative standard deviation values (less than 0.85%), accurate (recovery rate of 100.17+/-0.35%), and robust to changes in the mobile phase and column brand. The detection and quantitation limits were 0.08 and 0.24 microg/ml, respectively. The method was successfully used to determine the loading capacity and association efficiency of dapivirine in poly(lactic-co-glycolic acid)-based nanoparticles and its in vitro release. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  14. Multi-Analyte Separation Methods for HPLC Determination of the Active Ingredients of Pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Virtics, I.; Korsós, I.; Homoki, E.; Lantos, J. [Plant Protection and Soil Conservation Service of Szabolcs-Szatmár-Bereg County, Nyíregyháza (Hungary)

    2009-07-15

    The practical quality control of selected pesticides, such as carbamates, organophosphorous compounds, phthalimides, pyrethroids, with HPLC is described. Detailed descriptions are given of materials and methods used, including sample preparation and HPLC operating conditions. The relationship between pH value of the HPLC eluent and the logP{sub ow} is discussed, illustrated by chromatograms, graphics and tables. The results are also compared with those elaborated by. E. Dudar and presented above. (author)

  15. Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

    Directory of Open Access Journals (Sweden)

    S. K. Patro

    2010-01-01

    Full Text Available A simple, rapid and accurate and stability indicating RP-HPLC method was developed for the determination of valsartan in pure and tablet forms. The method showed a linear response for concentrations in the range of 50-175 µg/mL using 0.01 M NH4H2PO4 (pH 3.5 buffer: methanol [50:50] as the mobile phase with detection at 210 nm and a flow rate of 1 mL/min and retention time 11.041 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, forced degradation, solution stability and selectivity. Quantitative and recovery studies of the dosage form were also carried out and analyzed; the % RSD from recovery studies was found to be less than 1. Due to simplicity, rapidity and accuracy of the method, we believe that the method will be useful for routine quality control analysis.

  16. A novel HPLC method for the concurrent analysis and quantitation of seven water-soluble vitamins in biological fluids (plasma and urine): a validation study and application.

    Science.gov (United States)

    Giorgi, Margherita Grotzkyj; Howland, Kevin; Martin, Colin; Bonner, Adrian B

    2012-01-01

    An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B(1), B(2), B(5), B(6), B(9), B(12)) in biological matrices (plasma and urine). Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males). Interday and intraday precision were vitamins. Recovery percentages ranged from 93% to 100%.

  17. Development and validation of a HPLC method for the assay of dapivirine in cell-based and tissue permeability experiments.

    Science.gov (United States)

    das Neves, José; Sarmento, Bruno; Amiji, Mansoor; Bahia, Maria Fernanda

    2012-12-12

    Dapivirine, a non-nucleoside reverse transcriptase inhibitor, is being currently used for the development of potential anti-HIV microbicide formulations and delivery systems. A new high-performance liquid chromatography (HPLC) method with UV detection was developed for the assay of this drug in different biological matrices, namely cell lysates, receptor media from permeability experiments and homogenates of mucosal tissues. The method used a reversed-phase C18 column with a mobile phase composed of trifluoroacetic acid solution (0.1%, v/v) and acetonitrile in a gradient mode. Injection volume was 50μL and the flow rate 1mL/min. The total run time was 12min and UV detection was performed at 290nm for dapivirine and the internal standard (IS) diphenylamine. A Box-Behnken experimental design was used to study different experimental variables of the method, namely the ratio of the mobile phase components and the gradient time, and their influence in responses such as the retention factor, tailing factor, and theoretical plates for dapivirine and the IS, as well as the peak resolution between both compounds. The optimized method was further validated and its usefulness assessed for in vitro and ex vivo experiments using dapivirine or dapivirine-loaded nanoparticles. The method showed to be selective, linear, accurate and precise in the range of 0.02-1.5μg/mL. Other chromatographic parameters, namely carry-over, lower limit of quantification (0.02μg/mL), limit of detection (0.006μg/mL), recovery (equal or higher than 90.7%), and sample stability at different storage conditions, were also determined and found adequate for the intended purposes. The method was successfully used for cell uptake assays and permeability studies across cell monolayers and pig genital mucosal tissues. Overall, the proposed method provides a simple, versatile and reliable way for studying the behavior of dapivirine in different biological matrices and assessing its potential as an anti

  18. Screening natural antioxidants in peanut shell using DPPH-HPLC-DAD-TOF/MS methods.

    Science.gov (United States)

    Qiu, Jiying; Chen, Leilei; Zhu, Qingjun; Wang, Daijie; Wang, Wenliang; Sun, Xin; Liu, Xiaoyong; Du, Fangling

    2012-12-15

    Peanut shell, a byproduct in oil production, is rich in natural antioxidants. Here, a rapid and efficient method using DPPH-HPLC-DAD-TOF/MS was used for the first time to screen antioxidants in peanut shell. The method is based on the hypothesis that upon reaction with 1, 1-diphenyl-2-picrylhydrazyl (DPPH), the peak areas of compounds with potential antioxidant activities in the HPLC chromatogram will be significantly reduced or disappeared, and the identity confirmation could be achieved by HPLC-DAD-TOF/MS technique. With this method, three compounds possessing potential antioxidant activities were found abundantly in the methanolic extract of peanut shell. They were identified as 5,7-dihydroxychromone, eriodictyol, and luteolin. The contents of these compounds were 0.59, 0.92, and 2.36 mg/g, respectively, and luteolin possessed the strongest radical scavenging capacity. DPPH-HPLC-DAD-TOF/MS assay facilitated rapid identification and determination of natural antioxidants in peanut shell, which may be helpful for value-added utilization of peanut processing byproducts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Performances of CN-columns for the analysis of γ-oryzanol and its p-coumarate and caffeate derivatives by normal phase HPLC and a validated method of quantitation.

    Science.gov (United States)

    D'Ambrosio, Michele

    2013-06-15

    γ-Oryzanol is an important phytochemical used in pharmaceutical, alimentary and cosmetic preparations. The present article, for the first time, discloses the performances of NP-HPLC in separating γ-oryzanol components and develops a validated method for its routine quantification. The analysis is performed on a cyanopropyl bonded column using the hexane/MTBE gradient elution and UV detection at 325 nm. The method allows: the separation of steryl ferulate, p-coumarate and caffeate esters, the separation of cis- from trans-ferulate isomers, the splitting of steroid moieties into saturated and unsaturated at the side chain. The optimised method provides excellent linear response (R(2)=0.99997), high precision (RSD<1.0%) and satisfactory accuracy (R(∗)=70-86%). In conclusion, the established method presents the details of the procedure and the experimental conditions in order to achieve the required precision and instrumental accuracy. The method is fast and sensitive and it could be a suitable tool for quality assurance and determination of origin. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Resveratrol-loaded polymeric nanoparticles: validation of an HPLC-PDA method to determine the drug entrapment and evaluation of its antioxidant activity.

    Science.gov (United States)

    da Rocha Lindner, Gabriela; Khalil, Najeh Maissar; Mainardes, Rubiana Mara

    2013-01-01

    Poly(lactic acid) (PLA) and PLA-poly(ethylene glycol) (PLA-PEG) nanoparticles containing resveratrol (RVT) were developed, and their antioxidant activity was evaluated. An analytical method using high performance liquid chromatography (HPLC)/photodiode array (PDA) detection was also developed and validated for RVT determination in nanoparticles. The mobile phase consisted of methanol : water (51 : 49, v/v) flowed at 0.9 mL/min, and the PDA detector was set at wavelength of 306 nm. The mean diameter of the nanoparticles varied between 180 and 220 nm, and the encapsulation efficiency of RVT ranged from 60% to 88%. The nanoparticles containing RVT were evaluated for their ability to scavenge the radical (2,2-azinobis (3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt) (ABTS•⁺). The profile obtained from the PLA nanoparticles containing RVT demonstrated that after 24 h, there was almost no increase in antioxidant activity, which was lower than that of the free RVT and RVT-loaded PLA-PEG nanoparticles. For PLA-PEG nanoparticles, the radical-scavenging activity of RVT was shown to increase with time, and after 48 h, it was similar to that observed with free RVT.

  1. Resveratrol-Loaded Polymeric Nanoparticles: Validation of an HPLC-PDA Method to Determine the Drug Entrapment and Evaluation of Its Antioxidant Activity

    Directory of Open Access Journals (Sweden)

    Gabriela da Rocha Lindner

    2013-01-01

    Full Text Available Poly(lactic acid (PLA and PLA-poly(ethylene glycol (PLA-PEG nanoparticles containing resveratrol (RVT were developed, and their antioxidant activity was evaluated. An analytical method using high performance liquid chromatography (HPLC/photodiode array (PDA detection was also developed and validated for RVT determination in nanoparticles. The mobile phase consisted of methanol : water (51 : 49, v/v flowed at 0.9 mL/min, and the PDA detector was set at wavelength of 306 nm. The mean diameter of the nanoparticles varied between 180 and 220 nm, and the encapsulation efficiency of RVT ranged from 60% to 88%. The nanoparticles containing RVT were evaluated for their ability to scavenge the radical (2,2-azinobis (3-ethylbenzothiazoline-6-sulfonic acid diammonium salt (ABTS•+. The profile obtained from the PLA nanoparticles containing RVT demonstrated that after 24 h, there was almost no increase in antioxidant activity, which was lower than that of the free RVT and RVT-loaded PLA-PEG nanoparticles. For PLA-PEG nanoparticles, the radical-scavenging activity of RVT was shown to increase with time, and after 48 h, it was similar to that observed with free RVT.

  2. Development and validation of simple RP-HPLC-PDA analytical protocol for zileuton assisted with Design of Experiments for robustness determination

    OpenAIRE

    Saurabh B. Ganorkar; Dinesh M. Dhumal; Atul A. Shirkhedkar

    2017-01-01

    A simple, rapid, sensitive, robust, stability-indicating RP-HPLC-PDA analytical protocol was developed and validated for the analysis of zileuton racemate in bulk and in tablet formulation. Development of method and resolution of degradation products from forced; hydrolytic (acidic, basic, neutral), oxidative, photolytic (acidic, basic, neutral, solid state) and thermal (dry heat) degradation was achieved on a LC – GC Qualisil BDS C18 column (250 mm × 4.6 mm × 5 μm) by isocratic mode at ambie...

  3. DEVELOPMENT AND VALIDATION OF AN HPLC-DAD ANALYTICAL METHOD TO QUANTIFY 5-METHOXYFLAVONES IN METHANOLIC EXTRACTS OF Vochysia divergens POHL CULTURED UNDER STRESS CONDITIONS

    Directory of Open Access Journals (Sweden)

    Letícia Pereira Pimenta

    Full Text Available Vochysia divergens Pohl, known as "Cambara" in Brazil, is an invasive species that is expanding throughout Pantanal in Brazil, to form mono-dominant communities. This expansion is affecting the agricultural areas that support the typical seasonal flood and drought conditions of this biome. This article describes the development and validation of an HPLC-DAD analytical method to quantify 5-methoxyflavones in methanolic extracts of greenhouse-grown V. divergens associated with one of two endophytic fungal species Zopfiella tetraspora (Zt or Melanconiella elegans (Me and later subjected to water stress. The developed method gave good validation parameters and was successfully applied to quantify the flavones 3',5-dimethoxy luteolin-7-O-β-glucopyranoside (1, 5-methoxy luteolin (2, and 3',5-dimethoxy luteolin (3 in the target extracts. Inoculation of the plant with Zt decreased the concentration of flavone 1 in the extract by 2.69-fold as compared to the control. Inoculation of the plant with Zt or Me did not significantly alter the contents of flavones 2 and 3 in the extracts as compared to the control. Therefore, the aerial parts of germinated V. divergens plants inoculated with either Zt or Me responded differently in terms of the production of flavones. These results can cast light on the symbiosis between fungal microorganisms and V. divergens, which most likely influences the response of V. divergens to changes in the availability of water in Pantanal.

  4. Determination of some psychotropic drugs in serum and saliva samples by HPLC-DAD and HPLC MS.

    Science.gov (United States)

    Petruczynik, A; Wróblewski, K; Szultka-Młyńska, M; Buszewski, B; Karakuła-Juchnowicz, H; Gajewski, J; Morylowska-Topolska, J; Waksmundzka-Hajnos, M

    2016-08-05

    A simple, rapid and sensitive HPLC-DAD method has been developed and validated for the simultaneous determination of seven psychotropic drugs (risperidone, citalopram, clozapine,quetiapine, levomepromazine, perazine and aripiprazole) in human serum or saliva samples. The chromatographic analyses were performed on a XSELECT CSH Phenyl-Hexyl column with a mobile phase containing methanol, acetate buffer at pH 3.5 and 0.025mL(-1) diethylamine. The influence of concentration of methanol in injection samples and injection volume on peak symmetry and system efficiency was examined.The full separation of all investigated drugs, good peaks' symmetry and simultaneously high systems efficiency were obtained in applied chromatographic system. The method is suitable for the analysis of investigated drugs in human plasma or saliva for psychiatric patients for control of pharmacotherapy, particularly in combination therapy. HPLC-MS was applied for verification of the presence of drugs and their metabolites in serum and saliva samples from patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. A Novel HPLC Method for the Concurrent Analysis and Quantitation of Seven Water-Soluble Vitamins in Biological Fluids (Plasma and Urine: A Validation Study and Application

    Directory of Open Access Journals (Sweden)

    Margherita Grotzkyj Giorgi

    2012-01-01

    Full Text Available An HPLC method was developed and validated for the concurrent detection and quantitation of seven water-soluble vitamins (C, B1, B2, B5, B6, B9, B12 in biological matrices (plasma and urine. Separation was achieved at 30°C on a reversed-phase C18-A column using combined isocratic and linear gradient elution with a mobile phase consisting of 0.01% TFA aqueous and 100% methanol. Total run time was 35 minutes. Detection was performed with diode array set at 280 nm. Each vitamin was quantitatively determined at its maximum wavelength. Spectral comparison was used for peak identification in real samples (24 plasma and urine samples from abstinent alcohol-dependent males. Interday and intraday precision were <4% and <7%, respectively, for all vitamins. Recovery percentages ranged from 93% to 100%.

  6. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  7. Stability indicating RP-HPLC method for simultaneous determination of pantoprazole sodium and itopride hydrochloride in bulk and capsule

    Directory of Open Access Journals (Sweden)

    Krishna R. Gupta

    2011-03-01

    Full Text Available A stability indicating reversed-phase HPLC method has been developed and subsequently validated for simultaneous estimation of pantoprazole present as pantoprazole sodium sesquihydrate (PSS, and itopride hydrochloride from their combination product. The proposed RP-HPLC method utilizes a Phenomenex® C18, 5 µm, 250 mm X 4.6 mm i.d. column, mobile phase consisting of phosphate buffer and acetonitrile in the proportion of 55:45 (v/v with apparent pH adjusted to 5.0, and UV detection at 289.0 nm using a UV detector. PAN, ITH and their combination drug product were exposed to thermal, photolytic, hydrolytic and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. The described method was linear over a range of 4-20 µg/mL for PAN and 15-75 µg/mL for ITH. The mean recoveries were 100.02 and 99.88 for PAN and ITH, respectively. Chromatographic peak purity data of PAN and ITH indicated no co-eluting peaks with the main peaks of drugs which demonstrated the specificity of assay method for their estimation in presence of degradation products. The proposed method can be useful in the quality control of combination drug products.

  8. VERIFICATION HPLC METHOD OF QUANTITATIVE DETERMINATION OF AMLODIPINE IN TABLETS

    Directory of Open Access Journals (Sweden)

    Khanin V. A

    2014-10-01

    a volume of 100.0 ml. Preparation of the working standard solution sample amlodipine besylate. 50.0 mg of amlodipine RCC dissolved in methanol and dilute with the same solvent to 50.0 ml. 5.0 ml of this solution argue with methanol to volume 100.0 ml. Before the major controlled trials validated the existence of documents certifying the suitability vykorystovanoho equipment, raw materials and chemicals. Validation of the methodology was carried out in accordance with the requirements of SPhU. Results & discussion. Linearity methods defined within 80-120% of nominal concentrations. The linearity of the methods supported by the entire range of concentrations studied (b=0.9845, Sb=0,01473, a=1.5282, Sa=1.4956, S0=0.5486, r=0.9992. It is proved that the validated method characterized by sufficient convergence and accuracy over the entire range of concentrations (ΔZ=1.03, δ%=0.09. Conclusion. During verification methods of quantitative determination of amlodipine besylate tablets were studied characteristics validated HPLC method: accuracy, linearity, precision, specificity, and internal laboratory precision. Validation technique characteristics do not exceed the critical value of error (1.6% and characterized by qualitative analytical indicators. This technique can be correctly reproduced in the laboratory conditions, and is independent of the excipients.

  9. A validated HPLC-UV method for the analysis of galloylquinic acid derivatives and flavonoids in Copaifera langsdorffii leaves.

    Science.gov (United States)

    Motta, Erick Vicente da Silva; da Costa, Juliana de Carvalho; Bastos, Jairo Kenupp

    2017-09-01

    Copaifera langsdorffii Desf. (Fabaceae, Caesalpinioideae), popularly known as "copaiba" or "pau d'óleo", is a species of tree that is found throughout Brazil. The leaves of this tree are used in folk medicine to treat kidney stones. Galloylquinic acid derivatives and flavonoids are the main secondary metabolites found in C. langsdorffii leaves and are likely to be responsible for the effectiveness of this treatment. As an attempt to produce a phytotherapic, we have developed a reliable HPLC-UV method for the quality control of C. langsdorffii leaves. Phenolic compounds were extracted from C. langsdorffii leaves using 70% aqueous ethanol as the extraction solvent. HPLC-UV analyses were carried out on a Synergi Polar-RP column (100×3.0mm, 2.5μm), and the mobile phase was made up of formic acid-water (0.1:99.9, solvent A), and isopropanol-methanol-acetonitrile (5:40:60, solvent B). The elution gradient was A:B (90:10 to 85:15) in 8.0min, followed by A:B (85:15 to 64:36) up to 30.0min, using a flow rate of 0.7mL/min, and UV detection at 280nm. This method was used to quantify nine galloylquinic acid derivatives and two flavonoids, which gave a good detection response and linearity in the range of 1.88-110.0μg/mL. Furthermore, the detection and quantification limits ranged from 0.070 to 0.752μg/mL, and 0.211-2.278μg/mL respectively, with a maximum RSD of 4.18%. The method is reliable for the quality control of C. langsdorffii raw material, its hydroethanolic extract, and could potentially be used to quantify these compounds in other Copaifera species. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Prasad, K Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed

  11. A validated HPLC-PDA method for identification and quantification of two bioactive alkaloids, ephedrine and cryptolepine, in different Sida species.

    Science.gov (United States)

    Chatterjee, Arnab; Kumar, Satyanshu; Chattopadhyay, Sunil K

    2013-12-01

    A simple, rapid, accurate and reproducible reverse-phase HPLC method has been developed for the identification and quantification of two alkaloids ephedrine and cryptolepine in different extracts of Sida species using photodiode array detection. Baseline separation of the two alkaloids was achieved on a Waters RP-18 X-terra column (250 × 4.6 mm, 5 µm) using a solvent system consisting of a mixture of water containing 0.1% Trifluoroacetic acid (TFA) and acetonitrile in a gradient elution mode with detection at 210 and 280 nm for ephedrine and cryptolepine, respectively. The calibration curves were linear in a concentration range of 10-250 µg/mL for both the alkaloids with correlation coefficient values >0.99. The limits of detection and quantification for ephedrine and cryptolepine were 5 and 10 µg/mL and 2.5 and 5 µg/mL, respectively. Relative standard deviation values for intra-day and inter-day precision were 1.22 and 1.04% for ephedrine and 1.71 and 2.06% for cryptolepine, respectively. Analytical recovery ranged from 92.46 to 103.95%. The developed HPLC method was applied to identify and quantify ephedrine and cryptolepine in different extracts of Sida species. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    Science.gov (United States)

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  13. Improved method for HPLC analysis of polyamines, agmatine and aromatic monoamines in plant tissue

    Science.gov (United States)

    Slocum, R. D.; Flores, H. E.; Galston, A. W.; Weinstein, L. H.

    1989-01-01

    The high performance liquid chromatographic (HPLC) method of Flores and Galston (1982 Plant Physiol 69: 701) for the separation and quantitation of benzoylated polyamines in plant tissues has been widely adopted by other workers. However, due to previously unrecognized problems associated with the derivatization of agmatine, this important intermediate in plant polyamine metabolism cannot be quantitated using this method. Also, two polyamines, putrescine and diaminopropane, also are not well resolved using this method. A simple modification of the original HPLC procedure greatly improves the separation and quantitation of these amines, and further allows the simulation analysis of phenethylamine and tyramine, which are major monoamine constituents of tobacco and other plant tissues. We have used this modified HPLC method to characterize amine titers in suspension cultured carrot (Daucas carota L.) cells and tobacco (Nicotiana tabacum L.) leaf tissues.

  14. HPTLC and reverse phase HPLC methods for the simultaneous quantification and in vitro screening of antioxidant potential of isolated sesquiterpenoids from the rhizomes of Cyperus rotundus.

    Science.gov (United States)

    Priya Rani, M; Padmakumari, K P

    2012-09-01

    Three sesquiterpenoids solavetivone, aristolone and nootkatone were isolated from the acetone extract of Cyperus rotundus by silica gel column chromatography and identified by spectral studies. Solavetivone has been isolated for the first time from the species. Simple, sensitive and selective HPTLC and HPLC methods with ultraviolet detection (245 nm) were developed and validated for the simultaneous quantification. HPTLC method was validated in terms of their linearity, LOD, LOQ, precision, accuracy and compared with RP-HPLC-UV method. Among the three sesquiterpenoids isolated, nootkatone possessed the highest radical scavenging potential (IC(50) 4.81 μg/ml) followed by aristolone (IC(50) 5.28 μg/ml) and solavetivone (IC(50) 6.82 μg/ml) by DPPH radical scavenging assay. Total antioxidant activity against phosphomolybdenum reagent was also studied. The methods described in this paper were able to identify and quantify sesquiterpenoids from the complex mixtures of phytochemicals and could be extended to the marker based standardization of polyherbal formulations containing C. rotundus. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. A validated HPLC determination of the flavone aglycone diosmetin in human plasma.

    Science.gov (United States)

    Kanaze, Feras Imad; Bounartzi, Melpomeni I; Niopas, Ioannis

    2004-12-01

    Diosmetin, 3',5,7-trihydroxy-4'-methoxy flavone, is the aglycone of the flavonoid glycoside diosmin that occurs naturally in foods of plant origin. Diosmin exhibits antioxidant and anti-inflammatory activities, improves venous tone and it is used for the treatment of chronic venous insufficiency. Diosmin is hydrolyzed by enzymes of intestinal micro flora before absorption of its aglycone diosmetin. A specific, sensitive, precise, accurate and robust HPLC assay for the determination of diosmetin in human plasma was developed and validated. Diosmetin and the internal standard 7-ethoxycoumarin were isolated from plasma by liquid-liquid extraction and separated on a C8 reversed-phase column with methanol-water-acetic acid (55:43:2, v/v/v) as the mobile phase at 43 degrees C. Peaks were monitored at 344 nm. The method was linear in the 10-300 ng/mL concentration range (r > 0.999). Recovery for diosmetin and internal standard was greater than 89.7 and 86.8%, respectively. Intra-day and inter-day precision for diosmetin ranged from 1.6 to 4.6 and from 2.2 to 5.3%, respectively, and accuracy was better than 97.9%. Copyright 2004 John Wiley & Sons, Ltd.

  16. Development and validation of a stability-indicating RP-HPLC method for assay of betamethasone and estimation of its related compounds.

    Science.gov (United States)

    Fu, Qiang; Shou, Minshan; Chien, Dwight; Markovich, Robert; Rustum, Abu M

    2010-02-05

    Betamethasone (9alpha-fluoro-16beta-methylprednisolone) is one of the members of the corticosteriod family of active pharmaceutical ingredient (API), which is widely used as an anti-inflammatory agent and also as a starting material to manufacture various esters of betamethasone. A stability-indicating reverse-phase high performance liquid chromatography (RP-HPLC) method has been developed and validated which can separate and accurately quantitate low levels of 26 betamethasone related compounds. The stability-indicating capability of the method was demonstrated through adequate separation of all potential betamethasone related compounds from betamethasone and also from each other that are present in aged and stress degraded betamethasone stability samples. Chromatographic separation of betamethasone and its related compounds was achieved by using a gradient elution at a flow rate of 1.0mL/min on a ACE 3 C18 column (150mmx4.6mm, 3microm particle size, 100A pore size) at 40 degrees C. Mobile phase A of the gradient was 0.1% methanesulfonic acid in aqueous solution and mobile phase B was a mixture of tert-butanol and 1,4-dioxane (7:93, v/v). UV detection at 254nm was employed to monitor the analytes. For betamethasone 21-aldehyde, the QL and DL were 0.02% and 0.01% respectively. For betamethasone and the rest of the betamethasone related compounds, the QL and DL were 0.05% and 0.02%. The precision of betamethasone assay is 0.6% and the accuracy of betamethasone assay ranged from 98.1% to 99.9%.

  17. Determination and Quantification of the Vinblastine Content in Purple, Red, and White Catharanthus Roseus Leaves Using RP-HPLC Method

    Directory of Open Access Journals (Sweden)

    Rohanizah Abdul Rahim

    2018-03-01

    Full Text Available Purpose: To determine and quantify vinblastine in different varieties of Catharanthus roseus using reversed-phase HPLC method. Methods: The liquid chromatographic separation was performed using a reversed phase C18, Microsorb - MV column (250 mm x 4.6 mm, 5 µm at room temperature and eluted with a mobile phase containing methanol – phosphate buffer (5 mM, pH 6.0 – acetonitrile with different proportion gradient elution at a flow rate of 2.0 mL min-1 and detection at 254 nm. Results: The HPLC method was utilized for the quantification of vinblastine in purple, red and white varieties of Catharanthus roseus leaves. The separation was achieved in less than 8 min. The peak confirmation was done based on the retention times and UV spectra of the reference substance. The method was validated with respect to linearity, precision, recovery, limit of detection and quantification. Results showed that the purple variety gives 1.2 and 1.5 times more vinblastine concentration compared to the white and pink varieties, respectively. Conclusion: The obtained results from different varieties are thus useful for the purpose of vinblastine production from Catharanthus roseus plant.

  18. Determination of Bortezomib in API Samples Using HPLC: Assessment of Enantiomeric and Diastereomeric Impurities.

    Science.gov (United States)

    Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein

    2017-08-01

    A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. A Stability Indicating HPLC Method for the Determination of ...

    African Journals Online (AJOL)

    Erah

    stability indicating reverse phase HPLC method for estimating meloxicam (MLX) in bulk ... acetonitrile-water-glacial acetic acid [55:40:5 (% v/v)] at a flow rate of 1ml/min and detection wavelength .... pore and degassed before use. ... determined to assess the effect of small but ... deviation, the standard error of slope, and the.

  20. [Determination method of polysorbates in powdered soup by HPLC].

    Science.gov (United States)

    Takeda, Y; Abe, Y; Ishiwata, H; Yamada, T

    2001-04-01

    A method for qualitative and quantitative analyses of polysorbates in powdered soup by HPLC was studied. Polysorbates in samples were extracted with acetonitrile after rinsing with n-hexane to remove fats and oils. The extract was cleaned up using a Bond Elut silica gel cartridge (500 mg). The cartridge was washed with ethyl acetate and polysorbates were eluted with a small amount of acetonitrile-methanol (1:2) mixture. The eluate was treated with cobalt thiocyanate solution to form a blue complex with polysorbate. In order to determine polysorbate, the complex was subjected to HPLC with a GPC column, using a mixture of acetonitrile-water (95:5) as a mobile phase, with a detection wavelength of 620 nm. The recoveries of polysorbate 80 added to powdered soups were more than 75% and the determination limit was 0.04 mg/g. When the proposed method was applied to the determination of polysorbates in 16 commercial samples of powdered soup for instant noodles and seasoning consomme, no polysorbates were detected in any sample.

  1. Comparison on extraction yield of sennoside A and sennoside B from senna (Cassia angustifolia) using conventional and non conventional extraction techniques and their quantification using a validated HPLC-PDA detection method.

    Science.gov (United States)

    Dhanani, Tushar; Singh, Raghuraj; Reddy, Nagaraja; Trivedi, A; Kumar, Satyanshu

    2017-05-01

    Senna is an important medicinal plant and is used in many Ayurvedic formulations. Dianthraquinone glucosides are the main bioactive phytochemicals present in leaves and pods of senna. The extraction efficiency in terms of yield and composition of the extract of senna prepared using both conventional (cold percolation at room temperature and refluxing) and non conventional (ultrasound and microwave assisted solvent extraction as well as supercritical fluid extraction) techniques were compared in the present study. Also a rapid reverse phase HPLC-PDA detection method was developed and validated for the simultaneous determination of sennoside A and sennoside B in the different extracts of senna leaves. Ultrasound and microwave assisted solvent extraction techniques were more effective in terms of yield and composition of the extracts compared to cold percolation at room temperature and refluxing methods of extraction.

  2. An HPLC method to determine sennoside A and sennoside B in Sennae fructus and Sennae folium.

    Science.gov (United States)

    Rosenthal, Immanuel; Wolfram, Evelyn; Meier, Beat

    2014-01-01

    The current Ph. Eur. monographs for senna pods, senna leaf and senna leaf dry extract standardised describe a photometric assay based on the Bornträger reaction to determine hydroxyanthracene glycosides, calculated as sennoside B. The method is timeconsuming, unspecific for sennosides and the precision is not adequate for a modern assay. The photometric method shall therefore be replaced by a modern HPLC method. About 70 % of the total anthrachinone content in herbal drugs of senna species is due to sennoside A and sennoside B. These substances are therefore suitable for the standardisation of Senna products. The Japanese Pharmacopoeia (JP) already describes an HPLC method to determine sennoside A and sennoside B in the monograph for senna leaf. It uses ion-pair chromatography with tetraheptylammoniumbromide. The procedure described in the monograph has a runtime of 70 min. The adapted and validated method described here uses solid-phase extraction (SPE) which allows a selective sample preparation by using an anion exchange phase. A conventional RP C18 column Tosh TSKgel ODS-80TS (4.6 mm × 150 mm), 5 μm, was used as stationary phase and acetonitrile for chromatography R, water R, phosphoric acid R (200:800:1 V/V/V) as mobile phase. The flow rate was 1.2 mL/min, the column temperature 40 °C, the detection wavelength 380 nm, and the injection volume 20 μL. The runtime is 10 min, the chromatogram shows 2 peaks due to sennoside A/B and 2 additional smaller compounds. One of them is rhein-8-O-glucoside. The procedure has been successfully validated according to ICH guidelines. We analysed 6 batches of Senna. The pods (Senna angustifolia) showed a total content of sennoside A and B of 1.74-2.76 % m/m and the content of senna leaves was clearly lower with 1.07-1.19 % m/m, respectively. The suggested method is considered to be suitable to determine sennoside A and sennoside B in senna leaves and senna pods. The consideration is based on the performed validation and on

  3. Development and validation of analytical method for the estimation of nateglinide in rabbit plasma

    Directory of Open Access Journals (Sweden)

    Nihar Ranjan Pani

    2012-12-01

    Full Text Available Nateglinide has been widely used in the treatment of type-2 diabetics as an insulin secretogoga. A reliable, rapid, simple and sensitive reversed-phase high performance liquid chromatography (RP-HPLC method was developed and validated for determination of nateglinide in rabbit plasma. The method was developed on Hypersil BDSC-18 column (250 mm×4.6 mm, 5 mm using a mobile phase of 10 mM phosphate buffer (pH 2.5 and acetonitrile (35:65, v/v. The elute was monitored with the UV–vis detector at 210 nm with a flow rate of 1 mL/min. Calibration curve was linear over the concentration range of 25–2000 ng/mL. The retention times of nateglinide and internal standard (gliclazide were 9.608 min and 11.821 min respectively. The developed RP-HPLC method can be successfully applied to the quantitative pharmacokinetic parameters determination of nateglinide in rabbit model. Keywords: HPLC, Nateglinide, Rabbit plasma, Pharmacokinetics

  4. The Second SeaWiFS HPLC Analysis Round-Robin Experiment (SeaHARRE-2)

    Science.gov (United States)

    2005-01-01

    Eight international laboratories specializing in the determination of marine pigment concentrations using high performance liquid chromatography (HPLC) were intercompared using in situ samples and a variety of laboratory standards. The field samples were collected primarily from eutrophic waters, although mesotrophic waters were also sampled to create a dynamic range in chlorophyll concentration spanning approximately two orders of magnitude (0.3 25.8 mg m-3). The intercomparisons were used to establish the following: a) the uncertainties in quantitating individual pigments and higher-order variables (sums, ratios, and indices); b) an evaluation of spectrophotometric versus HPLC uncertainties in the determination of total chlorophyll a; and c) the reduction in uncertainties as a result of applying quality assurance (QA) procedures associated with extraction, separation, injection, degradation, detection, calibration, and reporting (particularly limits of detection and quantitation). In addition, the remote sensing requirements for the in situ determination of total chlorophyll a were investigated to determine whether or not the average uncertainty for this measurement is being satisfied. The culmination of the activity was a validation of the round-robin methodology plus the development of the requirements for validating an individual HPLC method. The validation process includes the measurements required to initially demonstrate a pigment is validated, and the measurements that must be made during sample analysis to confirm a method remains validated. The so-called performance-based metrics developed here describe a set of thresholds for a variety of easily-measured parameters with a corresponding set of performance categories. The aggregate set of performance parameters and categories establish a) the overall performance capability of the method, and b) whether or not the capability is consistent with the required accuracy objectives.

  5. Collaborative study for the validation of an improved HPLC assay for recombinant IFN-alfa-2.

    Science.gov (United States)

    Jönsson, K H; Daas, A; Buchheit, K H; Terao, E

    2016-01-01

    The current European Pharmacopoeia (Ph. Eur.) texts for Interferon (IFN)-alfa-2 include a nonspecific photometric protein assay using albumin as calibrator and a highly variable cell-based assay for the potency determination of the protective effects. A request was expressed by the Official Medicines Control Laboratories (OMCLs) for improved methods for the batch control of recombinant interferon alfa-2 bulk and market surveillance testing of finished products, including those formulated with Human Serum Albumin (HSA). A HPLC method was developed at the Medical Products Agency (MPA, Sweden) for the testing of IFN-alfa-2 products. An initial collaborative study run under the Biological Standardisation Programme (BSP; study code BSP039) revealed the need for minor changes to improve linearity of the calibration curves, assay reproducibility and robustness. The goal of the collaborative study, coded BSP071, was to transfer and further validate this improved HPLC method. Ten laboratories participated in the study. Four marketed IFN-alfa-2 preparations (one containing HSA) together with the Ph. Eur. Chemical Reference Substance (CRS) for IFN-alfa-2a and IFN-alfa-2b, and in-house reference standards from two manufacturers were used for the quantitative assay. The modified method was successfully transferred to all laboratories despite local variation in equipment. The resolution between the main and the oxidised forms of IFN-alfa-2 was improved compared to the results from the BSP039 study. The improved method even allowed partial resolution of an extra peak after the principal peak. Symmetry of the main IFN peak was acceptable for all samples in all laboratories. Calibration curves established with the Ph. Eur. IFN-alfa-2a and IFN-alfa-2b CRSs showed excellent linearity with intercepts close to the origin and coefficients of determination greater than 0.9995. Assay repeatability, intermediate precision and reproducibility varied with the tested sample within acceptable

  6. A Validated Method for the Quality Control of Andrographis paniculata Preparations.

    Science.gov (United States)

    Karioti, Anastasia; Timoteo, Patricia; Bergonzi, Maria Camilla; Bilia, Anna Rita

    2017-10-01

    Andrographis paniculata is a herbal drug of Asian traditional medicine largely employed for the treatment of several diseases. Recently, it has been introduced in Europe for the prophylactic and symptomatic treatment of common cold and as an ingredient of dietary supplements. The active principles are diterpenes with andrographolide as the main representative. In the present study, an analytical protocol was developed for the determination of the main constituents in the herb and preparations of A. paniculata . Three different extraction protocols (methanol extraction using a modified Soxhlet procedure, maceration under ultrasonication, and decoction) were tested. Ultrasonication achieved the highest content of analytes. HPLC conditions were optimized in terms of solvent mixtures, time course, and temperature. A reversed phase C18 column eluted with a gradient system consisting of acetonitrile and acidified water and including an isocratic step at 30 °C was used. The HPLC method was validated for linearity, limits of quantitation and detection, repeatability, precision, and accuracy. The overall method was validated for precision and accuracy over at least three different concentration levels. Relative standard deviation was less than 1.13%, whereas recovery was between 95.50% and 97.19%. The method also proved to be suitable for the determination of a large number of commercial samples and was proposed to the European Pharmacopoeia for the quality control of Andrographidis herba. Georg Thieme Verlag KG Stuttgart · New York.

  7. A simple and sensitive HPLC method for analysis of imipramine in human plasma with UV detection and liquid-liquid extraction: Application in bioequivalence studies.

    Science.gov (United States)

    Rezazadeh, Mahboubeh; Emami, Jaber

    2016-01-01

    High-performance liquid chromatography (HPLC) methods employing ultraviolet (UV) detector are not sufficiently sensitive to measure the low plasma concentrations following single oral dose of imipramine. Therefore, in the present study a simple, rapid and yet sensitive HPLC method with UV detection was developed and validated for quantitation of imipramine in human plasma samples. An efficient liquid-liquid extraction (LLE) of imipramine from plasma with the mixture of hexane/isoamyl alcohol (98:2) and back extraction of the drug in acidic medium concomitant with evaporation of organic phase allowed the use of UV detector to conveniently measure plasma levels of this compound as low level as 3 ng/ml. Separation was achieved on a μ-Bondapak C18 HPLC column using sodium hydrogen phosphate solution (0.01 M)/acetonitrile (60/40 v/v) at pH 3.5 ± 0.1 at 1.5 ml/min. Trimipramine was used as the internal standard for analysis of plasma samples. The retention times for imipramine and trimipramine were 4.3 and 5.2 min, respectively. Calibration curve was linear in the range of 3-40 ng/ml using human plasma with the average extraction recovery of 85 ± 5%. Imipramine was found to be stable in plasma samples with no evidence of degradation during three freeze-thaw cycles and three months storage at -70°C. The current validated method was finally applied in bioequivalence studies of two different imipramine products according to a standard two-way crossover design with a two weeks washout period.

  8. Rapid determination of flavonoids and phenolic acids in grape juices and wines by RP-HPLC/DAD: Method validation and characterization of commercial products of the new Brazilian varieties of grape.

    Science.gov (United States)

    Padilha, Carla Valéria da Silva; Miskinis, Gabriela Aquino; de Souza, Marcelo Eduardo Alves Olinda; Pereira, Giuliano Elias; de Oliveira, Débora; Bordignon-Luiz, Marilde Terezinha; Lima, Marcos Dos Santos

    2017-08-01

    A method for rapid determination of phenolic compounds by reversed-phase high-performance liquid chromatography (RP-HPLC), using a new column of faster resolution was validated and used to characterize commercial products produced with new grape Brazilian varieties of Northeast of Brazil. The in vitro antioxidant activity was also measured. The method showed linearity (R>0.9995), good precision (CV%<2.78), recovery (91.8-105.1%) and limits of detection (0.04-0.85mgL -1 ) and quantification (0.04-1.41mgL -1 ) according to other methods previously published with the difference of a run time of only 25min. The results obtained in the characterization of the samples differed for juices and wines from other world regions, mainly because of the high values of (-)-epigallocatechin and trans-caftaric acid. The products analyzed showed high antioxidant activity, especially the wine samples with values higher than those from wines of different regions of the world. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Ionisation constants of radiopharmaceuticals by HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Stylli, C.G.; Theobald, A.E.

    It has long been recognised that the pKsub(a) of drugs and radiopharmaceuticals is an important determinant of their biological distribution. In this study an HPLC method for pKa measurement has been developed for radiotracers. It has been validated with several amines and used to estimate the pKsub(a) values of some Tc-99m PnAO complexes by observing the change in chromatographic retention with change in mobile phase pH. The pKsub(a) values were estimated from the data by three methods: derivative analysis, quadratic regression, and the Henderson - Hasselbalch equation.

  10. Ionisation constants of radiopharmaceuticals by HPLC

    International Nuclear Information System (INIS)

    Stylli, C.G.; Theobald, A.E.

    1986-01-01

    It has long been recognised that the pKsub(a) of drugs and radiopharmaceuticals is an important determinant of their biological distribution. In this study an HPLC method for pKa measurement has been developed for radiotracers. It has been validated with several amines and used to estimate the pKsub(a) values of some Tc-99m PnAO complexes by observing the change in chromatographic retention with change in mobile phase pH. The pKsub(a) values were estimated from the data by three methods: derivative analysis, quadratic regression, and the Henderson - Hasselbalch equation. (author)

  11. Sample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat

    Science.gov (United States)

    Burckhardt, Bjoern B.; Laeer, Stephanie

    2015-01-01

    In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible to matrix effects. The latter restrains the precise drug quantification through, for example, causing signal suppression. Sophisticated sample preparation and purification utilizing solid-phase extraction was applied to reduce and control matrix effects. A scale-up from vacuum manifold to positive pressure manifold was conducted to meet the demands of high-throughput within a clinical setting. Faced challenges, advances, and experiences in solid-phase extraction are exemplarily presented on the basis of the bioanalytical method development and validation of low-volume samples (50 μL serum). Enalapril, enalaprilat, and benazepril served as sample drugs. The applied sample preparation and extraction successfully reduced the absolute and relative matrix effect to comply with international guidelines. Recoveries ranged from 77 to 104% for enalapril and from 93 to 118% for enalaprilat. The bioanalytical method comprising sample extraction by solid-phase extraction was fully validated according to FDA and EMA bioanalytical guidelines and was used in a Phase I study in 24 volunteers. PMID:25873972

  12. Sample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat

    Directory of Open Access Journals (Sweden)

    Bjoern B. Burckhardt

    2015-01-01

    Full Text Available In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible to matrix effects. The latter restrains the precise drug quantification through, for example, causing signal suppression. Sophisticated sample preparation and purification utilizing solid-phase extraction was applied to reduce and control matrix effects. A scale-up from vacuum manifold to positive pressure manifold was conducted to meet the demands of high-throughput within a clinical setting. Faced challenges, advances, and experiences in solid-phase extraction are exemplarily presented on the basis of the bioanalytical method development and validation of low-volume samples (50 μL serum. Enalapril, enalaprilat, and benazepril served as sample drugs. The applied sample preparation and extraction successfully reduced the absolute and relative matrix effect to comply with international guidelines. Recoveries ranged from 77 to 104% for enalapril and from 93 to 118% for enalaprilat. The bioanalytical method comprising sample extraction by solid-phase extraction was fully validated according to FDA and EMA bioanalytical guidelines and was used in a Phase I study in 24 volunteers.

  13. An HPLC method for determination of azadirachtin residues in bovine muscle.

    Science.gov (United States)

    Gai, María Nella; Álvarez, Christian; Venegas, Raúl; Morales, Javier

    2011-04-01

    A high-performance liquid chromatography (HPLC) method for the determination of azadirachtin (A and B) residues in bovine muscle has been developed. Azadirachtin is a neutral triterpene and chemotherapeutic agent effective in controlling some pest flies in horses, stables, horns and fruit. The actual HPLC method uses an isocratic elution and UV detection. Liquid-liquid extraction and solid-phase purification was used for the clean-up of the biological matrix. The chromatographic determination of these components is achieved using a C18 analytical column with water-acetonitrile mixture (27.5:72.5, v/v) as mobile phase, 1 mL/min as flow rate, 45 °C column temperature and UV detector at 215 nm. The azadirachtin peaks are well resolved and free of interference from matrix components. The extraction and analytical method developed in this work allows the quantitation of azadirachtin with precision and accuracy, establishing a lower limit of quantitation of azadirachtin, extracted from the biological matrix.

  14. An HPLC-UV method for the measurement of permeability of marker drugs in the Caco-2 cell assay

    Directory of Open Access Journals (Sweden)

    J.M. Kratz

    2011-06-01

    Full Text Available The Caco-2 cell line has been used as a model to predict the in vitro permeability of the human intestinal barrier. The predictive potential of the assay relies on an appropriate in-house validation of the method. The objective of the present study was to develop a single HPLC-UV method for the identification and quantitation of marker drugs and to determine the suitability of the Caco-2 cell permeability assay. A simple chromatographic method was developed for the simultaneous determination of both passively (propranolol, carbamazepine, acyclovir, and hydrochlorothiazide and actively transported drugs (vinblastine and verapamil. Separation was achieved on a C18 column with step-gradient elution (acetonitrile and aqueous solution of ammonium acetate, pH 3.0 at a flow rate of 1.0 mL/min and UV detection at 275 nm during the total run time of 35 min. The method was validated and found to be specific, linear, precise, and accurate. This chromatographic system can be readily used on a routine basis and its utilization can be extended to other permeability models. The results obtained in the Caco-2 bi-directional transport experiments confirmed the validity of the assay, given that high and low permeability profiles were identified, and P-glycoprotein functionality was established.

  15. A Rapid, Simple, and Validated RP-HPLC Method for Quantitative Analysis of Levofloxacin in Human Plasma

    Directory of Open Access Journals (Sweden)

    Dion Notario

    2017-04-01

    Full Text Available To conduct a bioequivalence study for a copy product of levofloxacin (LEV, a simple and validated analytical method was needed, but the previous developed methods were still too complicated. For this reason, a simple and rapid high performance liquid chromatography method was developed and validated for LEV quantification in human plasma. Chromatographic separation was performed under isocratic elution on a Luna Phenomenex® C18 (150 × 4.6 mm, 5 µm column. The mobile phase was comprised of acetonitrile, methanol, and phosphate buffer 25 mM that adjusted at pH 3.0 (13:7:80 v/v/v and pumped at a flow rate of 1.5 mL/min. Detection was performed under UV detector at wavelength of 280 nm. Samples were prepared by adding acetonitrile and followed by centrifugation to precipitate plasma protein. Then followed successively by evaporation and reconstitution step. The optimized method meets the requirements of validation parameters which included linearity (r = 0.995, sensitivity (LLOQ and LOD was 1.77 and 0.57 µg/mL respectively, accuracy (%error above LLOQ ≤ 12% and LLOQ ≤ 20%, precision (RSD ≤ 9%, and robustness in the ranges of 1.77-28.83 µg/mL. Therefore, the method can be used as a routine analysis of LEV in human plasma as well as in bioequivalence study of LEV.

  16. HPLC and LC-MS/MS methods for determination of sodium benzoate and potassium sorbate in food and beverages: performances of local accredited laboratories via proficiency tests in Turkey.

    Science.gov (United States)

    Gören, Ahmet C; Bilsel, Gökhan; Şimşek, Adnan; Bilsel, Mine; Akçadağ, Fatma; Topal, Kevser; Ozgen, Hasan

    2015-05-15

    High Performance Liquid Chromatography LC-UV and LC-MS/MS methods were developed and validated for quantitative analyses of sodium benzoate and potassium sorbate in foods and beverages. HPLC-UV and LC-MS/MS methods were compared for quantitative analyses of sodium benzoate and potassium sorbate in a representative ketchup sample. Optimisation of the methods enabled the chromatographic separation of the analytes in less than 4 min. A correlation coefficient of 0.999 was achieved over the measured calibration range for both compounds and methods (HPLC and LC-MS/MS). The uncertainty values of sodium benzoate and potassium sorbate were found as 0.199 and 0.150 mg/L by HPLC and 0.072 and 0.044 mg/L by LC-MS/MS, respectively. Proficiency testing performance of Turkish accredited laboratories between the years 2005 and 2013 was evaluated and reported herein. The aim of the proficiency testing scheme was to evaluate the performance of the laboratories, analysing benzoate and sorbate in tomato ketchup. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. An HPLC method for the determination of digoxin in dissolution samples

    Directory of Open Access Journals (Sweden)

    Milenković Miroslav Ž.

    2010-01-01

    Full Text Available An HPLC method for digoxin quantification in dissolution samples obtained as per the official British Pharmacopeia (BP method is presented in this paper. The chromatography was performed at 20 °C on a Symmetry C18; 3.5 ìm, 75 x 4.6 mm column with water - acetonitrile (72 : 28, v/v, as the mobile phase and UV detection at 220 nm. The method was found to be selective, linear, accurate and precise in the specified ranges. The LOD and LOQ were 0.015 μg mL-1 and 0.050 μg mL-1, respectively. Robustness testing was conducted to evaluate the impact of minor changes in the chromatographic parameters (i.e., acetonitrile fraction, flow rate of the mobile phase, column temperature and column length on the characteristics of the digoxin peak. A. full factorial design (24 was used to investigate the influence of the four variables The presented HPLC method was applied in quality and stability testing of Digoxin tablets 0.25 mg.

  18. Development and Validation of a Precise, Single HPLC Method for the Determination of Tolperisone Impurities in API and Pharmaceutical Dosage Forms

    OpenAIRE

    Raju, Thummala Veera Raghava; Seshadri, Raja Kumar; Arutla, Srinivas; Mohan, Tharlapu Satya Sankarsana Jagan; Rao, Ivaturi Mrutyunjaya; Nittala, Someswara Rao

    2012-01-01

    A novel, sensitive, stability-indicating HPLC method has been developed for the quantitative estimation of Tolperisone-related impurities in both bulk drugs and pharmaceutical dosage forms. Effective chromatographic separation was achieved on a C18 stationary phase with a simple mobile phase combination delivered in a simple gradient programme, and quantitation was by ultraviolet detection at 254 nm. The mobile phase consisted of a buffer and acetonitrile delivered at a flow rate 1.0 ml/min. ...

  19. Development of a HPLC method for determination of four UV filters in sunscreen and its application to skin penetration studies.

    Science.gov (United States)

    Souza, Carla; Maia Campos, Patrícia M B G

    2017-12-01

    This study describes the development, validation and application of a high-performance liquid chromatography (HPLC) method for the simultaneous determination of the in vitro skin penetration profile of four UV filters on porcine skin. Experiments were carried out on a gel-cream formulation containing the following UV filters: diethylamino hydroxybenzoyl hexyl benzoate (DHHB), bis-ethylhexyloxyphenol methoxyphenyl triazine (BEMT), methylene bis-benzotriazolyl tetramethylbutylphenol (MBBT) and ethylhexyl triazone (EHT). The HPLC method demonstrated suitable selectivity, linearity (10.0-50.0 μg/mL), precision, accuracy and recovery from porcine skin and sunscreen formulation. The in vitro skin penetration profile was evaluated using Franz vertical diffusion cells for 24 h after application on porcine ear skin. None of the UV filters penetrated the porcine skin. Most of them stayed on the skin surface (>90%) and only BEMT, EHT and DHHB reached the dermis plus epidermis layer. These results are in agreement with previous results in the literature. Therefore, the analytical method was useful to evaluate the in vitro skin penetration of the UV filters and may help the development of safer and effective sunscreen products. Copyright © 2017 John Wiley & Sons, Ltd.

  20. Comparison of calorimetric and HPLC methods in measuring nitrate content of meat products: An economic evaluation

    Directory of Open Access Journals (Sweden)

    M moradi

    2014-02-01

    Full Text Available Nitrate is a flavors compound, color stabilizer and growth inhibitor of anaerobic microorganisms in meat products. High concentration of nitrate in food can cause methaemoglobinaemia and is recognized as carcinogenic. Therefore, accurate determination of nitrate is crucial to ensure consumers’ health. Regularly, nitrate is estimated by colorimetric and HPLC methods. In measurement of nitrate, the efficiency, accuracy, speed and amount of material are important from economical point of view. In this study, the cost of initial investment, staff, consumable material and equipments used by the two methods were calculated and finally Net Present Value (NPV was estimated for each of them. The rate of interest was considered from 4 until 30%. According to the results the amount of initial investment, annual cost of staff and consumable materials for colorimetric method were determined as 274000000, 379080000 and 214289130 Rials, respectively. These costs for HPLC method were 342000000, 252720000 and 7633080 Rials, respectively. NPV in minimum and maximum rates of interest (4 and 30% for colorimetric method were 8368344000 and 2242330000 Rials and for HPLC method were estimated at 4035848000 and 1207544000 Rials. As a consequence, HPLC is more economical and could be recommended for the routine measurement of nitrate in of food safety laboratories.

  1. Quantification of Andrographolide Isolated from Andrographis paniculata Nees Obtained from Traditional Market in Yogyakarta Using Validated HPLC

    OpenAIRE

    Syukri, Yandi; Martien, Ronny; Lukitaningsih, Endang; Nugroho, Agung Endro

    2018-01-01

    This research was aimed to quantification of andrographolide isolated from A. paniculata Ness found in traditional market in Yogyakarta using validated HPLC to obtain high level content of andrographolide. The extraction of andrographolide from A. paniculata was carried out using ethanol as the solvent. Fractionation and isolation were continued using a non-polar solvent. Next, the extracts were re-crystallized to obtain isolated andrographolide. The identity of the compound was confirmed thr...

  2. Stability Indicating HPLC Method for Simultaneous Quantification of Trihexyphenidyl Hydrochloride, Trifluoperazine Hydrochloride and Chlorpromazine Hydrochloride from Tablet Formulation

    Directory of Open Access Journals (Sweden)

    P. Shetti

    2010-01-01

    Full Text Available A new, simple, precise, rapid, selective and stability indicating reversed-phase high performance liquid chromatographic (HPLC method has been developed and validated for simultaneous quantification of trihexyphenidyl hydrochloride, trifluoperazine hydrochloride and chlorpromazine hydrochloride from combined tablet formulation. The method is based on reverse-phase using C-18 (250×4.6 mm, 5 μm particle size column. The separation is achieved using isocratic elution by methanol and ammonium acetate buffer (1% w/v, pH 6.5 in the ratio of 85:15 v/v, pumped at flow rate 1.0 mL/min and UV detection at 215 nm. The column is maintained at 30 °C through out the analysis. This method gives baseline resolution. The total run time is 15 min. Stability indicating capability is established buy forced degradation experiment. The method is validated for specificity, accuracy, precision and linearity as per International conference of harmonisation (ICH. The method is accurate and linear for quantification of trihexyphenidyl hydrochloride, trifluoperazine hydrochloride and Chlorpromazine hydrochloride between 5 - 15 μg/mL, 12.5- 37.5 μg/mL and 62.5 - 187.5 μg/mL respectively.

  3. A simple RP-HPLC method for related substances of zoledronic acid in pharmaceutical products

    Directory of Open Access Journals (Sweden)

    L. Maheswara Reddy

    2017-02-01

    Full Text Available A novel, selective and sensitive reverse phase-high performance liquid chromatography (RP-HPLC method has been developed for the validated estimation of imidazol-1-yl-acetic acid in zoledronic acid formulations. The separation was achieved on a 5 μ C18 column (250 × 4.6 mm using a mobile phase that consists of the buffer (4.5 g of di-potassium hydrogen phosphate anhydrous and 2.0 g of tetra butyl ammonium hydrogen sulphate (TBAHS in 1000 mL of water and methanol in the ratio of 900:100 v/v. The flow rate was maintained at 1.0 mL min−1. The detection of the constituents was done at 215 nm using a UV detector. The retention times of imidazol-1-yl-acetic acid and zoledronic acid were 7.2 and 10.2 min respectively. Recovery studies were satisfactory and the correlation coefficient, 0.999 indicates linearity of the method within the limits. The developed method can be applicable for regular qualitative analysis.

  4. A Simple and Sensitive HPLC Method for Simultaneous Analysis of Nabumetone and Paracetamol in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Prafulla Kumar Sahu

    2011-01-01

    Full Text Available This paper describes a high-performance liquid chromatographic method for simultaneous estimation of nabumetone and paracetamol in binary mixture. The method was based on RP-HPLC separation and quantitation of the two drugs on hypersil C-18 column (250 mm × 4.6 mm using a mobile phase consisting of acetonitrile and 0.05% aqueous acetic acid (70:30v/v at flow rate of 1 mL min-1. Quantitation was achieved with PDA detector at 238 nm based on peak area with linear calibration curves at concentration ranges 5-25 µg mL-1 for both the drugs. Naproxen sodium was used as internal standard. The method has been successively applied to pharmaceutical formulation. No chromatographic interference from the tablet excipients was found. The method was validated in terms of precision, robustness, recovery and limits of detection and quantitation. The intra and inter-day precision and accuracy values were in the acceptance range as per ICH guidelines.

  5. Pressurised liquid extraction of flavonoids in onions. Method development and validation

    DEFF Research Database (Denmark)

    Søltoft, Malene; Christensen, J.H.; Nielsen, J.

    2009-01-01

    A rapid and reliable analytical method for quantification of flavonoids in onions was developed and validated. Five extraction methods were tested on freeze-dried onions and subsequently high performance liquid chromatography (HPLC) with UV detection was used for quantification of seven flavonoids...... extraction methods. However. PLE was the preferred extraction method because the method can be highly automated, use only small amounts of solvents, provide the cleanest extracts, and allow the extraction of light and oxygen-sensitive flavonoids to be carried out in an inert atmosphere protected from light......-step PLE method showed good selectivity, precision (RSDs = 3.1-11%) and recovery of the extractable flavonoids (98-99%). The method also appeared to be a multi-method, i.e. generally applicable to, e.g. phenolic acids in potatoes and carrots....

  6. Determination of impurities and degradation products from veterinary medicinal products by HPLC method

    Directory of Open Access Journals (Sweden)

    Elena Gabriela Oltean

    2014-06-01

    Full Text Available The organic or inorganic impurities in the veterinary medicinal product can derive from starting materials, manufacturing process, incomplete purification, inappropriate storage. The acceptable levels of impurities in pharmaceuticals are estimated by comparison with standard solutions, according to the appropriate monographs. Forced degradation studies determine the stability of the method of dosage for the active compounds and for the entire finished product under excessive accelerated degradation conditions. They also provide information on degradation pathways and selectivity of analytical methods applied. The information provided by the degradation studies on the active compound and finished pharmaceutical product should demonstrate the specificity of the analytical method regarding impurities. Forced degradation studies should demonstrate that the impurities and degradation products generated do not interfere with the active compound. The current forced degradation methods consist of acid hydrolysis, basic hydrolysis, oxidation, exposure of the medicinal product to temperature and light. HPLC methods are an integral analytical instrument for the analysis of the medicinal product. The HPLC method should be able to separate, detect and quantify various specific degradation products that can appear after manufacture or storage of the medicinal product, as well as new elements appearing after synthesis. FDA and ICH guidelines recommend the enclosure of the results, including the chromatograms specific to the forced degradation-subjected medicinal product, in the documentation for marketing authorization. Using HPLC methods in forced degradation studies on medicinal products provides relevant information on the method of determination for the formulation of the medicinal product, synthesis product, packaging methods and storage.

  7. Development and Validation of a HPLC-UV Method for the Evaluation of Ellagic Acid in Liquid Extracts of Eugenia uniflora L. (Myrtaceae Leaves and Its Ultrasound-Assisted Extraction Optimization

    Directory of Open Access Journals (Sweden)

    Paulo Isaac Dias Assunção

    2017-01-01

    Full Text Available A simple HPLC-UV method has been developed and validated for the quantification of ellagic acid (EA in ethanol extracts of Eugenia uniflora L. (Myrtaceae leaves. The ultrasound-assisted extraction (UAE optimization was performed using a Box Behnken design (33 combined with response surface methodology to study the effects of the ethanol concentration (%, w/w, extraction time (minutes, and temperature (°C on the EA concentration. The optimized results showed that the highest extraction yield of EA by UAE was 26.0 μg mL−1 when using 44% (w/w ethanol as the solvent, 22 minutes as the extraction time, and 59°C as the extraction temperature. The concentration of EA in relation to the predicted value was 93.7%  ±  0.4. UAE showed a strong potential for EA extraction.

  8. Development and Validation of a HPLC-UV Method for the Evaluation of Ellagic Acid in Liquid Extracts of Eugenia uniflora L. (Myrtaceae) Leaves and Its Ultrasound-Assisted Extraction Optimization.

    Science.gov (United States)

    Assunção, Paulo Isaac Dias; da Conceição, Edemilson Cardoso; Borges, Leonardo Luiz; de Paula, Joelma Abadia Marciano

    2017-01-01

    A simple HPLC-UV method has been developed and validated for the quantification of ellagic acid (EA) in ethanol extracts of Eugenia uniflora L. (Myrtaceae) leaves. The ultrasound-assisted extraction (UAE) optimization was performed using a Box Behnken design (3 3 ) combined with response surface methodology to study the effects of the ethanol concentration (%, w/w), extraction time (minutes), and temperature (°C) on the EA concentration. The optimized results showed that the highest extraction yield of EA by UAE was 26.0  μ g mL -1 when using 44% (w/w) ethanol as the solvent, 22 minutes as the extraction time, and 59°C as the extraction temperature. The concentration of EA in relation to the predicted value was 93.7%  ±  0.4. UAE showed a strong potential for EA extraction.

  9. RP-HPLC method for simultaneous estimation of vigabatrin, gamma-aminobutyric acid and taurine in biological samples.

    Science.gov (United States)

    Police, Anitha; Shankar, Vijay Kumar; Narasimha Murthy, S

    2018-02-15

    Vigabatrin is used as first line drug in treatment of infantile spasms for its potential benefit overweighing risk of causing permanent peripheral visual field defects and retinal damage. Chronic administration of vigabatrin in rats has demonstrated these ocular events are result of GABA accumulation and depletion of taurine levels in retinal tissues. In vigabatrin clinical studies taurine plasma level is considered as biomarker for studying structure and function of retina. The analytical method is essential to monitor taurine levels along with vigabatrin and GABA. A RP-HPLC method has been developed and validated for simultaneous estimation of vigabatrin, GABA and taurine using surrogate matrix. Analytes were extracted from human plasma, rat plasma, retina and brain by simple protein precipitation method and derivatized by naphthalene 2, 3‑dicarboxaldehyde to produce stable fluorescent active isoindole derivatives. The chromatographic analysis was performed on Zorbax Eclipse AAA column using gradient elution profile and eluent was monitored using fluorescence detector. A linear plot of calibration curve was observed in concentration range of 64.6 to 6458, 51.5 to 5150 and 62.5 to 6258 ng/mL for vigabatrin, GABA and taurine, respectively with r 2  ≥ 0.997 for all analytes. The method was successfully applied for estimating levels of vigabatrin and its modulator effect on GABA and taurine levels in rat plasma, brain and retinal tissue. This RP-HPLC method can be applied in clinical and preclinical studies to explore the effect of taurine deficiency and to investigate novel approaches for alleviating vigabatrin induced ocular toxicity. Copyright © 2018. Published by Elsevier B.V.

  10. A NEW HPLC METHOD FOR SEPARATION OF PHYTOPLANKTON PIGMENTS IN NATURAL SAMPLES

    Science.gov (United States)

    A new high-performance liquid chromatographic (HPLC) method was developed to analyze, in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a reverse-phase amide C16 (RP-amide C16) column and an elution gradient o...

  11. Development and validation of a new HPLC-UV method for the simultaneous determination of triclabendazole and ivermectin B1a in a pharmaceutical formulation.

    Science.gov (United States)

    Shurbaji, Maher; Abu Al Rub, Mohamad H; Saket, Munib M; Qaisi, Ali M; Salim, Maher L; Abu-Nameh, Eyad S M

    2010-01-01

    A rapid, simple, and sensitive RP-HPLC analytical method was developed for the simultaneous determination of triclabendazole and ivermectin in combination using a C18 RP column. The mobile phase was acetonitrile-methanol-water-acetic acid (56 + 36 + 7.5 + 0.5, v/v/v/v) at a pH of 4.35 and flow rate of 1.0 mL/min. A 245 nm UV detection wavelength was used. Complete validation, including linearity, accuracy, recovery, LOD, LOQ, precision, robustness, stability, and peak purity, was performed. The calibration curve was linear over the range 50.09-150.26 microg/mL for triclabendazole with r = 0.9999 and 27.01-81.02 microg/mL for ivermectin with r = 0.9999. Calculated LOD and LOQ for triclabendazole were 0.03 and 0.08 microg/mL, respectively, and for ivermectin 0.07 and 0.20 microg/mL, respectively. The intraday precision obtained was 98.71% with RSD of 0.87% for triclabendazole and 100.79% with RSD 0.73% for ivermectin. The interday precision obtained was 99.51% with RSD of 0.35% for triclabendazole and 100.55% with RSD of 0.59% for ivermectin. Robustness was also studied, and there was no significant variation of the system suitability of the analytical method with small changes in experimental parameters.

  12. Validation of high-performance liquid chromatography (HPLC method for quantitative analysis of histamine in fish and fishery products

    Directory of Open Access Journals (Sweden)

    B.K.K.K. Jinadasa

    2016-12-01

    Full Text Available A high-performance liquid chromatography method is described for quantitative determination and validation of histamine in fish and fishery product samples. Histamine is extracted from fish/fishery products by homogenizing with tri-chloro acetic acid, separated with Amberlite CG-50 resin and C18-ODS Hypersil reversed phase column at ambient temperature (25°C. Linear standard curves with high correlation coefficients were obtained. An isocratic elution program was used; the total elution time was 10 min. The method was validated by assessing the following aspects; specificity, repeatability, reproducibility, linearity, recovery, limits of detection, limit of quantification and uncertainty. The validated parameters are in good agreement with method and it is a useful tool for determining histamine in fish and fishery products.

  13. Validated high performance liquid chromatographic (HPLC) method ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-22

    Feb 22, 2010 ... specific and accurate high performance liquid chromatographic method for determination of ZER in micro-volumes ... tional medicine as a cure for swelling, sores, loss of appetite and ... Receptor Activator for Nuclear Factor κ B Ligand .... The effect of ... be suitable for preclinical pharmacokinetic studies. The.

  14. Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method

    Directory of Open Access Journals (Sweden)

    Semahat Kucukkolbasi

    2013-01-01

    Full Text Available In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid and four fat-soluble vitamins (retinol acetate, cholecalciferol, α-tocopherol, and phytonadione in multivitamin tablets. The linearity of the method was excellent (R² > 0.999 over the concentration range of 10 - 500 ng mL-1. The statistical evaluation of the method was carried out by performing the intra- and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims.

  15. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    Science.gov (United States)

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  16. HPLC method for urinary theobromine determination: Effect of consumption of cocoa products on theobromine urinary excretion in children.

    Science.gov (United States)

    Rodriguez, Adrian; Costa-Bauza, Antonia; Saez-Torres, Concepcion; Rodrigo, Dolores; Grases, Felix

    2015-11-01

    To validate a simple method of urinary theobromine determination, to assess urinary theobromine levels in 80 healthy children and to relate these levels to consumption of cocoa products. Urine samples were diluted, directly injected into an HPLC system, separated by gradient elution on a C18 column, and detected by UV spectrometry. The method was validated for linearity, limits of detection and quantification, imprecision, accuracy, recovery and interferences. The proposed method was used to assess 12-h day and 12-h night urinary theobromine excretion by 80 healthy children, divided into four groups based on consumption of cocoa products. In addition, urinary excretion of magnesium and oxalate, also present in cocoa, was measured in these four groups. The method was linear to a theobromine concentration of 278μmol/L (50mg/L). LOD and LOQ for urine samples, diluted 1:5 (vol/vol) with water, were 1.1 and 3.6μmol/L respectively. Within-run and between-run imprecisions (CV) were each cocoa products (pcocoa products. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. HPLC Method for Simultaneous Quantitative Detection of Quercetin and Curcuminoids in Traditional Chinese Medicines

    Directory of Open Access Journals (Sweden)

    Lee Fung Ang

    2014-12-01

    Full Text Available Objectives: Quercetin and curcuminoids are important bioactive compounds found in many herbs. Previously reported high performance liquid chromatography ultraviolet (HPLC-UV methods for the detection of quercetin and curcuminoids have several disadvantages, including unsatisfactory separation times and lack of validation according the standard guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. Methods: A rapid, specific, reversed phase, HPLC-UV method with an isocratic elution of acetonitrile and 2% v/v acetic acid (40% : 60% v/v (pH 2.6 at a flow rate of 1.3 mL/minutes, a column temperature of 35°C, and ultraviolet (UV detection at 370 nm was developed. The method was validated and applied to the quantification of different types of market available Chinese medicine extracts, pills and tablets. Results: The method allowed simultaneous determination of quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin in the concentration ranges of 0.00488 ─ 200 μg/mL, 0.625 ─ 320 μg/mL, 0.07813 ─ 320 μg/mL and 0.03906 ─ 320 μg/mL, respectively. The limits of detection and quantification, respectively, were 0.00488 and 0.03906 μg/mL for quercetin, 0.62500 and 2.50000 μg/mL for bisdemethoxycurcumin, 0.07813 and 0.31250 μg/mL for demethoxycurcumin, and 0.03906 and 0.07813 μg/mL for curcumin. The percent relative intra day standard deviation (% RSD values were 0.432 ─ 0.806 μg/mL, 0.576 ─ 0.723 μg/ mL, 0.635 ─ 0.752 μg/mL and 0.655 ─ 0.732 μg/mL for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and those for intra day precision were 0.323 ─ 0.968 μg/mL, 0.805 ─ 0.854 μg/mL, 0.078 ─ 0.844 μg/mL and 0.275 ─ 0.829 μg/mL, respectively. The intra day accuracies were 99.589% ─ 100.821%, 98.588% ─ 101.084%, 9.289% ─ 100.88%, and 98.292% ─ 101.022% for quercetin, bisdemethoxycurcumin

  18. Implementación, validación y aplicación de un nuevo método para la determinación de oxitetraciclina por HPLC en tejido muscular de salmonídeos Implementation, validation, and application of a new HPLC method to determine oxytetracycline in salmonid muscle tissue

    Directory of Open Access Journals (Sweden)

    Cristian Aguilera

    2010-01-01

    Full Text Available Se implementa y valida un método para identificar y cuantificar la oxitetraciclina en músculo de salmón, cuantificar los niveles de recuperación de oxitetraciclina y estudiar su fármaco cinética en diferentes órganos de salmones. La implementación correspondió a la detección y cuantificación de residuos del antibiótico en el tejido muscular de salmonídeos. El principio de la metodología HPLC incluyó la determinación de una serie de soluciones representativas de los estándares utilizados en la fortificación de las muestras. El tiempo de retención fue de 5,7 min. La validación del método, busca confirmar y documentar que los resultados entregados por el método implementado sean confiables. Para esto se llevaron a cabo análisis de parámetros tales como: selectividad, precisión, exactitud, sensibilidad e incertidumbre. Los resultados obtenidos señalan que el porcentaje de recuperación, es de un 96%. El coeficiente de correlación (R de la curva de calibrado es 0,9946 y el coeficiente de variación 1,86%.A method for identifying and quantifying oxytetracycline in salmon muscle, for quantifying oxytetracycline recovery levels, and for studying its pharmacokinetic in different organs of salmonids was implemented and validated. During implementation, antibiotic residues were detected and quantified in salmon muscle tissue. The principle of the HPLC methodology included determining a series of representative solutions of the standards, used to fortify the samples. The retention time was 5.7 min. The validation of the method sought to confirm and document the reliability of the results obtained with this method. For this, several parameters (selectivity, precision, accuracy, sensitivity, uncertainty were analyzed. The results obtained indicated 96% recovery. The coefficient of correlation (R of the calibration curve was 0.9946 and the coefficient of variation was 1.86%.

  19. An optimized high-performance liquid chromatography (HPLC method for benzoylmesaconine determination in Radix Aconiti Lateralis Preparata (Fuzi, aconite roots and its products

    Directory of Open Access Journals (Sweden)

    Xu Hongxi

    2008-05-01

    Full Text Available Abstract Background Benzoylmesaconine (BMA is the main Aconitum alkaloid in Radix Aconiti Lateralis Preparata (Fuzi, aconite roots with potent pharmacological activities, such as analgesia and anti-inflammation. The present study developed a simple and reliable method using BMA as a marker compound for the quality control of processed aconite roots and their products. Methods After extraction, a high-performance liquid chromatography (HPLC determination of BMA was conducted on a RP-C18 column by gradient elution with acetonitrile and aqueous phase, containing 0.1% phosphoric acid adjusted with triethylamine to pH 3.0. Results A distinct peak profile was obtained and separation of BMA was achieved. Method validation showed that the relative standard deviations (RSDs of the precision of BMA in all intra-day and inter-day assays were less than 1.36%, and that the average recovery rate was 96.95%. Quantitative analysis of BMA showed that the content of BMA varied significantly in processed aconite roots and their products. Conclusion This HPLC method using BMA as a marker compound is applicable to the quality control of processed aconite roots and their products.

  20. TOXICOLOGICAL DRUG SCREENING BY GC-MS VERSUS HPLC-DAD USING A COMMON EFFICIENT EXTRACTION PROCEDURE SCREENING TOXICOLOGIQUE DES MEDICAMENTS PAR HPLC-DAD ET GC-MS: PROTOCOLE D’EXTRACTION UNIQUE

    Directory of Open Access Journals (Sweden)

    SELOUA ELMRABEH

    2015-05-01

    Full Text Available This paper presents a common extraction method for toxicological drug screening by gas chromatography-mass spectrometry (GC-MS and high-performance liquid chromatography with diode-array detection (HPLC-DAD. Liquid-liquid extraction was performed using plasma of 104 samples at the Laboratory of Moroccan Poison Control and Pharmacovigilance Center during a period of 12 months. The results obtained by HPLC-DAD are compared with those determined with GC-MS. 76 cases (73.08 % were found positive for at least by one of these two techniques. HPLC-DAD identified 59.87 % of all positive results, and 10 molecules were identified only by HPLC-DAD. GC/MS identified 40.13 % of all positives, and 4 molecules were identified only by GC/MS. In order to evaluate the performance of this extraction method, an extraction yield was calculated for three classes of drugs. All the analyzed molecules were obtained in satisfactory yields (higher than 50 % except for carbamazepine, amitriptyline and nortriptyline. Overall, the results indicate that the extraction method is well adapted for toxicological drug screening. The use of common extraction simultaneously for the two techniques can reduce workload and costs of screening, while increasing the validity and reliability of the results.

  1. Kinetic Study of the Alkaline Degradation of Oseltamivir Phosphate and Valacyclovir Hydrochloride using Validated Stability Indicating HPLC

    Directory of Open Access Journals (Sweden)

    Ramzia I. Al-Bagary

    2014-01-01

    Full Text Available Aqueous alkaline degradation was performed for oseltamivir phosphate (OP and valacyclovir hydrochloride (VA. Isocratic stability indicating the use of high-performance liquid chromatography (HPLC was presented for each drug in the presence of its degradation product. The separations were performed using the Nucleosil ODS column and a mobile phase consisting of phosphate buffer (pH = 7, acetonitrile, and methanol 50:25:25 (v/v/v for OP. For VA separation, a Nucleosil CN column using phosphate buffer (pH = 7 and methanol 85:15 (v/v was used as a mobile phase. Ultraviolet detection at 210 nm and 254 nm was used for OP and VA, respectively. The method showed high sensitivity concerning linearity, accuracy, and precision over the range 1-250 μg mL −1 for both drugs. The proposed method was used to determine the drug in its pharmaceutical formulation and to investigate the degradation kinetics of each drug's alkaline-stressed samples. The reactions were found to follow a first-order reaction. The activation energy could also be estimated. International Conference on Harmonisation guidelines were adopted for method validation.

  2. Validated HPLC method for the quantitative determination of CoQ(10) in dog plasma and its application to a pharmacokinetic study.

    Science.gov (United States)

    Yuan, Bo; Liu, Chunling; Xu, Pingwei; Lin, Lin; Pan, Cheng; Wang, Linglan; Xu, Haiyan

    2011-09-01

    Coenzyme Q(10) (CoQ(10) ) is a naturally occurring compound located in all membranes throughout the cell. A rapid and sensitive HPLC method was developed to determine the concentration of CoQ(10) in dog plasma using a surrogate matrix. Chromatographic separation was carried out on a Diamonsil C(18) column with the UV detector set at 275 nm. Methanol-2-propanol (40:60, v/v) was used as a mobile phase delivered at a flow rate of 1.0 mL/min. Calibrators were prepared using blank plasma-K(2) HPO(4) buffer (50 mm, pH 8.0)-saline (1:3:6, v/v/v) as surrogate matrix. It was shown that the surrogate matrix had similar properties to dog plasma for CoQ(10) in extraction, freeze-thaw and stability. The assay was linear over the concentration range of 0.10-100 µg/mL. The intra- and inter-day precisions were within 13.3% in terms of relative standard deviation (RSD%) and the accuracy was within ±7.5% in terms of relative error. This simple and reproducible HPLC method with less plasma volume (0.4 mL) and adequate sensitivity was successfully applied to pharmacokinetic studies of CoQ(10) in dogs and an investigation of the effect of CoQ(10) formulation on CoQ(10) baseline levels. Copyright © 2010 John Wiley & Sons, Ltd.

  3. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays.

    Science.gov (United States)

    Leung, Elvis M K; Chan, Wan

    2014-02-01

    Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.

  4. Dual-mode gradient HPLC procedure for the simultaneous determination of chloroquine and proguanil.

    Science.gov (United States)

    Paci, A; Caire-Maurisier, A-M; Rieutord, A; Brion, F; Clair, P

    2002-01-01

    In order to assay the antipaludic capsule of the Service de Santé des Armées (SSA), that contains two antimalarial drugs, i.e. chloroquine sulfate (CQS, cp1) and proguanil hydrochloride (PGH, cp5), a HPLC procedure was developed. A reversed-phase ion-pair high-performance liquid chromatography (HPLC) method with an ultraviolet detection at 254 nm was set up and validated. Elution system includes programming of both organic concentration and flow-rate known as 'dual-mode gradient'. This method allows the simultaneous determination of both active compounds and separation of four process related substances. The method is simple, rapid, selective and accurate, and the precision is good with an inter- and intra-assay of <2%. The sensitivity is particularly suitable for pharmaceutical quality control.

  5. A novel HPLC-MS/MS method for the simultaneous determination of astemizole and its major metabolite in dog or monkey plasma and application to pharmacokinetics.

    Science.gov (United States)

    Back, Hyun-moon; Lee, Jong-Hwa; Chae, Jung-woo; Song, Byungjeong; Seo, Joung-Wook; Yun, Hwi-yeol; Kwon, Kwang-il

    2015-10-10

    Astemizole (AST), a second-generation antihistamine, is metabolized to desmethyl astemizole (DEA), and although it has been removed from the market for inducing QT interval prolongation, it has reemerged as a potential anticancer and antimalarial agent. This report describes a novel high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for simultaneously determining the concentrations of AST and DEA in beagle dog and cynomolgus monkey plasma with simple preparation method and short retention time. Prior to HPLC analyses, the plasma samples were extracted with simple liquid-liquid extraction method. The isocratic mobile phase was 0.025% trifluoroacetic acid (TFA dissolved in acetonitrile) and 20 mM ammonium acetate (94:6) at a flow rate of 0.25 mL/min and diphenhydramine used as internal standard. In MS/MS analyses, precursor ions of the analytes were optimized as protonated molecular ions: [M+H](+). The lower limit of quantification of astemizole was 2.5 ng/mL in both species and desmethyl astemizole were 7.5 ng/mL and 10 ng/mL in dog and monkey plasma, respectively. The accuracy, precision, and stability of the method were in accordance with FDA guidelines for the validation of bioanalytical methods. Finally this validated method was successfully applied to a pharmacokinetic study in dogs and monkeys after oral administration of 10 mg/kg AST. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. HPLC method for simultaneous quantitative detection of quercetin and curcuminoids in traditional chinese medicines.

    Science.gov (United States)

    Ang, Lee Fung; Yam, Mun Fei; Fung, Yvonne Tan Tze; Kiang, Peh Kok; Darwin, Yusrida

    2014-12-01

    Quercetin and curcuminoids are important bioactive compounds found in many herbs. Previously reported high performance liquid chromatography ultraviolet (HPLC-UV) methods for the detection of quercetin and curcuminoids have several disadvantages, including unsatisfactory separation times and lack of validation according the standard guidelines of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. A rapid, specific, reversed phase, HPLC-UV method with an isocratic elution of acetonitrile and 2% v/v acetic acid (40% : 60% v/v) (pH 2.6) at a flow rate of 1.3 mL/minutes, a column temperature of 35°C, and ultraviolet (UV) detection at 370 nm was developed. The method was validated and applied to the quantification of different types of market available Chinese medicine extracts, pills and tablets. The method allowed simultaneous determination of quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin in the concentration ranges of 0.00488 ─ 200 μg/mL, 0.625 ─ 320 μg/mL, 0.07813 ─ 320 μg/mL and 0.03906 ─ 320 μg/mL, respectively. The limits of detection and quantification, respectively, were 0.00488 and 0.03906 μg/mL for quercetin, 0.62500 and 2.50000 μg/mL for bisdemethoxycurcumin, 0.07813 and 0.31250 μg/mL for demethoxycurcumin, and 0.03906 and 0.07813 μg/mL for curcumin. The percent relative intra day standard deviation (% RSD) values were 0.432 ─ 0.806 μg/mL, 0.576 ─ 0.723 μg/mL, 0.635 ─ 0.752 μg/mL and 0.655 ─ 0.732 μg/mL for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and those for intra day precision were 0.323 ─ 0.968 μg/mL, 0.805 ─ 0.854 μg/mL, 0.078 ─ 0.844 μg/mL and 0.275 ─ 0.829 μg/mL, respectively. The intra day accuracies were 99.589% ─ 100.821%, 98.588% ─ 101.084%, 9.289% ─ 100.88%, and 98.292% ─ 101.022% for quercetin, bisdemethoxycurcumin, demethoxycurcumin and curcumin, respectively, and the

  7. Comparative determination of sibutramine as an adulterant in natural slimming products by HPLC and HPTLC densitometry.

    Science.gov (United States)

    Ariburnu, Etil; Uludag, Mehmet Fazli; Yalcinkaya, Huseyin; Yesilada, Erdem

    2012-05-01

    A new validated method for the identification and quantification of the sibutramine was developed by HPTLC-densitometry at 225 nm and advantages and disadvantages compared with HPLC-FLD at 225 nm emission and 316 nm excitation. Both methods were applied to the analysis of three natural slimming products in the market for the quantitative analysis of illegally added sibutramine. HPTLC separations were performed on (20 cm × 10 cm) glass HPTLC plates coated with silica gel 60 F(254) using a mobile phase, n-hexane-acetone-ammonia (10:1:0.1, v/v/v). For HPLC analysis, a phenyl column (5.0 μm, 150 mm × 4.6 mm, i.d.) and an isocratic mobile phase of acetonitrile-water-formic acid (pH 3.0; 0.19M) (45:55:0.78, v/v/v) was used. The calibration curve area versus concentration was found to be linear in the range of 250-2000 ng/spot(-1) and 5-200 μg/ml for HPTLC and HPLC, respectively. Both methods were validated for accuracy, precision, linearity, selectivity, recovery and short term stability. As a conclusion, these methods were found to be useful for the routine analysis of illegally added sibutramine in the marketed products. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. A New Validated RP- HPLC Method for the Determination of Nevirapine in Human Plasma

    Directory of Open Access Journals (Sweden)

    C. H. Venkata Kumar

    2010-01-01

    Full Text Available A rapid, selective and sensitive high performance liquid chromatographic method for the estimation of nevirapine in human plasma has been developed. Chromatography was carried out on a Hypersil BDS C18 column using a mixture of ammonium acetate buffer (pH 4.0 ± 0.05 and acetonitrile (85:15 v/v as the mobile phase. The eluents were monitored for the drug by UV detection at 254 nm. Oxcarbazepine was used as an internal standard for this study. The retention times for nevirapine and oxcarbazepine were found to be 7.2 and 14.7 min respectively. The method was found to be linear in the concentration range of 50 ng/mL to 5003.7 ng/mL. The method was validated as per FDA guidelines and was found to be suitable for bioequivalence and pharmacokinetic studies.

  9. Theoretische en practische aspecten van het gebruik van micro-HPLC

    NARCIS (Netherlands)

    de Fluiter P; Jansen EHJM

    1992-01-01

    A practical and theoretical approach for the implementation of micro high performance liquid chromatography (HPLC) is described. A new simple and rapid test procedure was developed in wich a HPLC system can be validated for its suitability for micro-bore columns. It appeared that the detector

  10. Validação de métodos cromatográficos de análise: um experimento de fácil aplicação utilizando cromatografia líquida de alta eficiência (CLAE e os princípios da "Química Verde" na determinação de metilxantinas em bebidas Validation of chromatographic methods: an experiment using HPLC and Green Chemistry in methylxanthines determination

    Directory of Open Access Journals (Sweden)

    Nádia Machado de Aragão

    2009-01-01

    Full Text Available The validation of analytical methods is an important step in quality control. The main objective of this study is to propose an HPLC experiment to verify the parameters of validation of chromatographic methods, based on green chemistry principles, which can be used in experimental courses of chemistry and related areas.

  11. Validation of the Analytical Method for the Determination of Flavonoids in Broccoli

    Directory of Open Access Journals (Sweden)

    Tuszyńska Magdalena

    2014-09-01

    Full Text Available A simple, accurate and selective HPLC method was developed and validated for determination of quercetin and kaempferol, which are the main flavonols in broccoli. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of methanol/water (60/40 and phosphoric acid 0.2% at a flow rate of 1.0 ml min-1. The detection was carried out on a DAD detector at 370 nm. This method was validated according to the requirements for new methods, which include selectivity, linearity, precision, accuracy, limit of detection and limit of quantitation. The current method demonstrates good linearity, with R2 > 0.99. The recovery is within 98.07-102.15% and 97.92-101.83% for quercetin and kaempferol, respectively. The method is selective, in that quercetin and kaempferol are well separated from other compounds of broccoli with good resolution. The low limit of detection and limit of quantitation of quercetin and kaempferol enable the detection and quantitation of these flavonoids in broccoli at low con–centrations.

  12. Establishment of analytical methods for analysis of pesticides and organic chlorides by hplc

    International Nuclear Information System (INIS)

    Ghaffar, A.; Mashiatullah, A.; Javed, T.

    2012-01-01

    Methods for the analysis of organic chlorides and pesticides like dichlorophenol (DCP), DDT, Chlorpyrifos, Cypermethrin, Melathion, Diazinon and Pendimathalin by HPLC equipped with UV detector were established. The methods were optimized by applying different wavelengths and by changing the composition of mobile phase and flow rates. A series of analysis were performed to optimize the solvent composition, flow rate and wave length for analysis. The standard solutions with different concentration were prepared and run on HPLC. The calibration curves constructed from the peak area versus concentrations were linear (r = 0. 99). Efficiency of the developed methods was tested by taking known quantities of compounds in sample media by spiking separate portions of samples and repeating the analysis. The accuracy of the established methods was checked by interference and spiking the samples with the standard solution. The sample was analyzed and spiked with equal volume of standard solution. The calculated and actual analyzed concentrations were compared for the accuracy of method. The recoveries of samples ranged between 96-98 %, which prove the accuracy of the established methods. (orig./A.B.)

  13. Development and validation of an HPLC method for stability evaluation of nystatin

    Directory of Open Access Journals (Sweden)

    Ana Paola Prata Cione

    2010-06-01

    Full Text Available A liquid chromatography method for evaluating the stability of Nystatin (Nys in an ointment was developed and validated, since the traditional pharmacopeial microbiological methods are unable to indicate stability. The stress experiments showed that Nys was found to significantly degrade in alkaline and acidic conditions and also under oxidative stress. Lower levels of degradation were detected under heat and with the sample exposed to Xenon light. Resolutions higher than 2 for Nys and degradation products (DP chromatographic peaks were achieved by using an Inerstil ODS-3 column, isocratic elution with methanol:water and UV detection at 305 nm. The system was found to be linear over a range of 102 to 310 IU mL-1 and proved precise, since the RSD(% was 0.24% for the six replicates tested. The method also exhibited good levels of recovery (from 98.24% to 100.74%. Therefore, the validation fulfilled pharmacopeial requirements and the procedure was found to be reliable, precise, accurate and selective for determination of Nys and its degradation products.Um método indicador de estabilidade por cromatografia líquida foi desenvolvido e validado para a análise de Nistatina (Nys em uma pomada, uma vez que os métodos microbiológicos tradicionais não têm a habilidade de serem indicadores de estabilidade. A nistatina degradou significativamente em condições alcalinas e ácidas e também em meio oxidante. Quando a amostra foi exposta a luz de xenônio, foram observados menores níveis de degradação. A resolução entre os picos cromatográficos de Nys e seus produtos de degradação (PD foi maior que 2, utilizando-se uma coluna Inerstil ODS-3, eluição isocrática com metanol: água e detecção no UV em 305 nm. O sistema foi linear entre a faixa de 102 a 310 UI mL-1 e preciso uma vez que o DPR(% foi de 0,24% entre as seis replicatas testadas. Além disso, o método exibiu bons níveis de recuperação (de 98,24% a 100,74%. Consequentemente

  14. Chiral chromatography studies of chemical behavior of cinacalcet on polysaccharide chiral reversed-phase HPLC stationary phases.

    Science.gov (United States)

    Dousa, Michal; Brichác, Jirí

    2012-01-01

    A rapid HPLC method for the analytical resolution of cinacalcet enantiomers was developed. Four chiral columns (two amylose and two cellulose type) were evaluated in RP systems. Excellent enantioseparation with a resolution of more than 6 was achieved on Chiralpak AY (amylose 5-chloro-2-methylphenylcarbamate chiral stationary phase) using 10 mM triethylamine (pH 8.0)-acetonitrile (40 + 60, v/v) mobile phase. Validation of the HPLC method, including linearity, LOD, LOQ, precision, accuracy, and selectivity, was performed according to the International Conference on Harmonization guidelines. The method was successfully applied for the determination of (S)-cinacalcet in enantiopure active pharmaceutical ingredient (R)-cinacalcet.

  15. A validated specific stability-indicating RP-HPLC assay method for Ambrisentan and its related substances.

    Science.gov (United States)

    Narayana, M B V; Chandrasekhar, K B; Rao, B M

    2014-09-01

    A validated specific stability-indicating reverse-phase liquid chromatographic method was developed for the quantitative determination of Ambrisentan as well as its related substances in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its related impurities. Forced degradation studies were performed on bulk samples of Ambrisentan as per the ICH-prescribed stress conditions using acid, base, oxidative, thermal stress and photolytic degradation to show the stability-indicating power of the LC method. Significant degradation in acidic, basic stress conditions was observed and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from the forced degradation studies and the impurity-spiked solution. Good resolution between the peaks corresponds to Ambrisentan-related impurities and degradation products from the analyte were achieved on a SunFire C18 column using a mobile phase consisting of a mixture of potassium dihydrogen orthophosphate at a pH adjusted to 2.5 with ortho-phosphoric acid in water and a mixture of acetonitrile:methanol using a simple linear gradient. The detection was carried out at 225 nm. The limit of detection and the limit of quantification for the Ambrisentan and its related impurities were established. The stressed test solutions were assayed against the qualified working standard of Ambrisentan and the mass balance in each case was between 98.9 and 100.3%, indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per the ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Ambrisentan at the time of batch release and also during its storage (long-term and accelerated stability). © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    Science.gov (United States)

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Optimization and validation of bioanalytical SPE – HPLC method for the simultaneous determination of carbamazepine and its main metabolite, carbamazepine-10, 11-epoxide, in plasma

    Directory of Open Access Journals (Sweden)

    Jasmina Tonic – Ribarska

    2012-03-01

    Full Text Available Carbamazepine is widely used as an antiepileptic drug in the treatment of partial and generalized tonic-clonic seizures. Carbamazepine 10,11-epoxide is the most important metabolite of carbamazepine, because it is a pharmacologically active compound with anticonvulsant properties. According to that, the routine analysis of carbamazepine 10,11-epoxide along with carbamazepine may provide optimal therapeutic monitoring of carbamazepine treatment. The aim of this study was to optimize and validate a simple and reliable solid - phase extraction method followed by RP-HPLC for the simultaneous determination of plasma levels of carbamazepine and carbamazepine-10,11-epoxide, in order to assure the implementation of the method for therapeutic monitoring. The extraction of the analytes from the plasma samples was performed by means of a solid-phase extraction procedure. The separation was carried out on a reversed-phase column using isocratic elution with acetonitrile and water (35:65, v/v as a mobile phase. The temperature was 30°C and UV detection was set at 220 nm. The extraction yield values were more than 98% for all analytes, measured at four concentration levels of the linear concentration range. The method displayed excellent selectivity, sensitivity, linearity, precision and accuracy. Stability studies indicate that stock solutions and plasma samples were stabile under different storage conditions at least during the observed period. The method was successfully applied to determine the carbamazepine and carbamazepine-10,11-epoxide in plasma of epileptic patients treated with carbamazepine as monotherapy and in polytherapy. In conclusion, the proposed method is suitable for application in therapeutic drug monitoring of epileptic patients undergoing treatment with carbamazepine.

  18. A thin film degradation study of a fluorinated polyether liquid lubricant using an HPLC method

    Science.gov (United States)

    Morales, W.

    1986-01-01

    A High Pressure Liquid Chromatography (HPLC) separation method was developed to study and analyze a fluorinated polyether fluid which is promising liquid lubricant for future applications. This HPLC separation method was used in a preliminary study investigating the catalytic effect of various metal, metal alloy, and ceramic engineering materials on the degradation of this fluid in a dry air atmosphere at 345 C. Using a 440 C stainless steel as a reference catalytic material it was found that a titanium alloy and a chromium plated material degraded the fluorinated polyether fluid substantially more than the reference material.

  19. Development of an HPLC post-column antioxidant assay for Solidago canadensis radical scavengers.

    Science.gov (United States)

    Marksa, Mindaugas; Radušienė, Jolita; Jakštas, Valdas; Ivanauskas, Liudas; Marksienė, Rūta

    2016-01-01

    The aim of this work was to modify and validate the post-column high-performance liquid chromatography (HPLC)-ABTS and DPPH methods for evaluating the antioxidant activity of the methanolic extracts of Solidago canadensis (Canadian goldenrod) leaves and flowers. Separation of the analytes was performed via the HPLC-PDA method on a YMC analytical column using a gradient elution program. Three compounds with antioxidant properties - chlorogenic acid, rutin and isoquercitrin - and two unidentified antioxidants were established. The research showed that the coil temperature regimes and loop length combinations influence the optimised post-column assay method for detecting the antioxidant activity of goldenrod radical scavengers. Investigations established that the temperature in the reaction coil was a substantial factor contributing to the signal strength of the analytes after reacting with the DPPH and ABTS radicals.

  20. Development and validation of a high-performance liquid chromatography method with post-column derivatization for the detection of aflatoxins in cereals and grains.

    Science.gov (United States)

    Asghar, Muhammad Asif; Iqbal, Javed; Ahmed, Aftab; Khan, Mobeen Ahmed; Shamsuddin, Zuzzer Ali; Jamil, Khalid

    2016-06-01

    A novel, reliable and rapid high-performance liquid chromatography (HPLC) method with post-column derivatization was developed and validated. The HPLC method was used for the simultaneous determination of aflatoxin B1 (AFB1), B2 (AFB2), G1 (AFG1) and G2 (AFG2) in various cereals and grains. Samples were extracted with 80:20 (v/v) methanol:water and purified using C18 (40-63 μm) solid-phase extraction cartridges. AFs were separated using a LiChroCART-RP-18 (5 μm, 250 × 4.0 mm(2)) column. The mobile phase consisted of methanol:acetonitrile:buffer (17.5:17.5:65 v/v) (pH 7.4) delivered at the flow rate of 1.0 mL min(-1) The fluorescence of each AF was detected at λex = 365 nm and λem = 435 nm. All four AFs were properly resolved within the total run time of 20 min. The established method was extensively validated as a final verification of the method development by the evaluation of selectivity (AFB1, AFB2, AFG1 and AFG2), linearity (R(2) ≥ 0.9994), precision (average SD ≤ 2.79), accuracy (relative mean error ≤ -5.51), robustness (p HPLC method could be effectively applied for the routine analysis of the AFs in different cereals and grains. © The Author(s) 2014.

  1. Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method.

    Science.gov (United States)

    Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, Mahmoudreza; Karami-Osboo, Rouhollah

    2013-01-01

    Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL(-1) and low detection limit (13.1 ng mL(-1)). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%.

  2. Comparison of HPLC, UV spectrophotometry and potentiometric titration methods for the determination of lumefantrine in pharmaceutical products.

    Science.gov (United States)

    da Costa César, Isabela; Nogueira, Fernando Henrique Andrade; Pianetti, Gérson Antônio

    2008-09-10

    This paper describes the development and evaluation of a HPLC, UV spectrophotometry and potentiometric titration methods to quantify lumefantrine in raw materials and tablets. HPLC analyses were carried out using a Symmetry C(18) column and a mobile phase composed of methanol and 0.05% trifluoroacetic acid (80:20), with a flow rate of 1.0ml/min and UV detection at 335nm. For the spectrophotometric analyses, methanol was used as solvent and the wavelength of 335nm was selected for the detection. Non-aqueous titration of lumefantrine was carried out using perchloric acid as titrant and glacial acetic acid/acetic anhydride as solvent. The end point was potentiometrically determined. The three evaluated methods showed to be adequate to quantify lumefantrine in raw materials, while HPLC and UV methods presented the most reliable results for the analyses of tablets.

  3. Quantification of whey proteins by reversed phase-HPLC and effectiveness of mid-infrared spectroscopy for their rapid prediction in sweet whey.

    Science.gov (United States)

    Sturaro, Alba; De Marchi, Massimo; Masi, Antonio; Cassandro, Martino

    2016-01-01

    In the dairy industry, membrane filtration is used to reduce the amount of whey waste and, simultaneously, to recover whey proteins (WP). The composition of WP can strongly affect the filtration treatment of whey, and rapid determination of WP fractions would be of interest for dairy producers to monitor WP recovery. This study aimed to develop mid-infrared spectroscopy (MIRS) prediction models for the rapid quantification of protein in sweet whey, using a validated rapid reversed phase (RP)-HPLC as a reference method. Quantified WP included α-lactalbumin (α-LA), β-lactoglobulin (β-LG) A and B, bovine serum albumin, caseinomacropeptides, and proteose peptone. Validation of RP-HPLC was performed by calculating the relative standard deviation (RSD) in repeatability and reproducibility tests for WP retention time and peak areas. Samples of liquid whey (n=187) were analyzed by RP-HPLC and scanned through MIRS to collect spectral information (900 to 4,000 cm(-1)); statistical analysis was carried out through partial least squares regression and random cross-validation procedure. Retention times in RP-HPLC method were stable (RSD between 0.03 and 0.80%), whereas the RSD of peak area (from 0.25 to 8.48%) was affected by WP relative abundance. Higher coefficients of determination in validation for MIRS model were obtained for protein fractions present in whey in large amounts, such as β-LG (0.58), total identified WP (0.58), and α-LA (0.56). Results of this study suggest that MIRS is an easy method for rapid quantification of detail protein in sweet whey, even if better resolution was achieved with the method based on RP-HPLC. The prediction of WP in sweet whey by MIRS might be used for screening and for classifying sweet whey according to its total and individual WP contents. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Development and validation of simple RP-HPLC-PDA analytical protocol for zileuton assisted with Design of Experiments for robustness determination

    Directory of Open Access Journals (Sweden)

    Saurabh B. Ganorkar

    2017-02-01

    Full Text Available A simple, rapid, sensitive, robust, stability-indicating RP-HPLC-PDA analytical protocol was developed and validated for the analysis of zileuton racemate in bulk and in tablet formulation. Development of method and resolution of degradation products from forced; hydrolytic (acidic, basic, neutral, oxidative, photolytic (acidic, basic, neutral, solid state and thermal (dry heat degradation was achieved on a LC – GC Qualisil BDS C18 column (250 mm × 4.6 mm × 5 μm by isocratic mode at ambient temperature, employing a mobile phase methanol and (0.2%, v/v orthophosphoric acid in ratio of (80:20, v/v at a flow rate of 1.0 mL min−1 and detection at 260 nm. ‘Design of Experiments’ (DOE employing ‘Central Composite Design’ (CCD and ‘Response Surface Methodology’ (RSM were applied as an advancement to traditional ‘One Variable at Time’ (OVAT approach to evaluate the effects of variations in selected factors (methanol content, flow rate, concentration of orthophosphoric acid as graphical interpretation for robustness and statistical interpretation was achieved with Multiple Linear Regression (MLR and ANOVA. The method succeeded over the validation parameters: linearity, precision, accuracy, limit of detection and limit of quantitation, and robustness. The method was applied effectively for analysis of in-house zileuton tablets.

  5. Simultaneous Determination of Florfenicol and Diclazuril in Compound Powder by RP-HPLC-UV Method

    Directory of Open Access Journals (Sweden)

    Leilei Guo

    2014-01-01

    Full Text Available A RP-HPLC-UV method was developed and validated for simultaneous determination of florfenicol and diclazuril in compound powder. The separation involved using a SinoChoom ODS-BP C18 (5 μm, 4.6 mm × 250 mm analytical column. The mobile phase was a mixture of acetonitrile-0.2% phosphoric acid (pH was adjusted to 3.0 with triethylamine. The ratio of acetonitrile and 0.2% phosphoric acid in the mobile phase was 60 : 40 (v/v from 0 minutes to 6 minutes and 70 : 30 (v/v from 6.1 minutes to 15 minutes. The flow rate was 1 mL/min. The temperature of the analytical column was maintained at 30°C. The detection was monitored at 225 nm and 277 nm for florfenicol and diclazuril, respectively. The excipients in the compound powder did not interfere with the drug peaks. The calibration curves of florfenicol and diclazuril were fairly linear over the concentration ranges between 50.0–500.0 μg/mL (r=0.9995 and 10.0–100.0 μg/mL (r=0.9992, respectively. The RSD of both the intraday and interday variations was below 2.1% for florfenicol and diclazuril. The method was successfully validated according to International Conference on Harmonisation and proved to be suitable for the simultaneous determination of florfenicol and diclazuril in compound powder.

  6. Development of a new extraction technique and HPLC method for the analysis of non-psychoactive cannabinoids in fibre-type Cannabis sativa L. (hemp).

    Science.gov (United States)

    Brighenti, Virginia; Pellati, Federica; Steinbach, Marleen; Maran, Davide; Benvenuti, Stefania

    2017-09-05

    The present work was aimed at the development and validation of a new, efficient and reliable technique for the analysis of the main non-psychoactive cannabinoids in fibre-type Cannabis sativa L. (hemp) inflorescences belonging to different varieties. This study was designed to identify samples with a high content of bioactive compounds, with a view to underscoring the importance of quality control in derived products as well. Different extraction methods, including dynamic maceration (DM), ultrasound-assisted extraction (UAE), microwave-assisted extraction (MAE) and supercritical-fluid extraction (SFE) were applied and compared in order to obtain a high yield of the target analytes from hemp. Dynamic maceration for 45min with ethanol (EtOH) at room temperature proved to be the most suitable technique for the extraction of cannabinoids in hemp samples. The analysis of the target analytes in hemp extracts was carried out by developing a new reversed-phase high-performance liquid chromatography (HPLC) method coupled with diode array (UV/DAD) and electrospray ionization-mass spectrometry (ESI-MS) detection, by using an ion trap mass analyser. An Ascentis Express C 18 column (150mm×3.0mm I.D., 2.7μm) was selected for the HPLC analysis, with a mobile phase composed of 0.1% formic acid in both water and acetonitrile, under gradient elution. The application of the fused-core technology allowed us to obtain a significant improvement of the HPLC performance compared with that of conventional particulate stationary phases, with a shorter analysis time and a remarkable reduction of solvent usage. The analytical method optimized in this study was fully validated to show compliance with international requirements. Furthermore, it was applied to the characterization of nine hemp samples and six hemp-based pharmaceutical products. As such, it was demonstrated to be a very useful tool for the analysis of cannabinoids in both the plant material and its derivatives for

  7. Validação em métodos cromatográficos e eletroforéticos Validation for chromatographic and electrophoretic methods

    Directory of Open Access Journals (Sweden)

    Marcelo Ribani

    2004-10-01

    Full Text Available The validation of an analytical method is fundamental to implementing a quality control system in any analytical laboratory. As the separation techniques, GC, HPLC and CE, are often the principal tools used in such determinations, procedure validation is a necessity. The objective of this review is to describe the main aspects of validation in chromatographic and electrophoretic analysis, showing, in a general way, the similarities and differences between the guidelines established by the different Brazilian and international regulatory agencies.

  8. A Modified Method for Determination of Lumefantrine in Human Plasma by HPLC-UV and Combination of Protein Precipitation and Solid-Phase Extraction: Application to a Pharmacokinetic Study

    Directory of Open Access Journals (Sweden)

    Liusheng Huang

    2010-03-01

    Full Text Available An HPLC-UV method was developed and validated for the determination of lumefantrine in human plasma. Lumefantrine and its internal standard halofantrine were extracted from plasma samples using protein precipitation with acetonitrile (0.2% perchloric acid followed by solid-phase extraction with Hypersep C8 cartridges. Chromatographic separation was performed on a Zorbax SB-CN HPLC column (3.0 × 150 mm, 3.5 μm with water/methanol (0.1% TFA as the mobile phases in a gradient elution mode. Detection was performed using UV/vis detector at λ = 335 nm. The method showed to be linear over a range of 50–10,000 ng/mL with acceptable intra- and inter-day precision and accuracy. The mean recoveries were 88.2% for lumefatrine and 84.5% for the I.S. The internal standard halofantrine is readily available from commercial sources. This method was successfully applied to a pharmacokinetic interaction study between a first-line antimalarial combination (artemether—lumefantrine and antiretroviral therapy.

  9. A single extraction and HPLC procedure for simultaneous analysis of phytosterols, tocopherols and lutein in soybeans.

    Science.gov (United States)

    Slavin, Margaret; Yu, Liangli Lucy

    2012-12-15

    A saponification/extraction procedure and high performance liquid chromatography (HPLC) analysis method were developed and validated for simultaneous analysis of phytosterols, tocopherols and lutein (a carotenoid) in soybeans. Separation was achieved on a phenyl column with a ternary, isocratic solvent system of acetonitrile, methanol and water (48:22.5:29.5, v/v/v). Evaporative light scattering detection (ELSD) was used to quantify β-sitosterol, stigmasterol, campesterol, and α-, δ- and γ-tocopherols, while lutein was quantified with visible light absorption at 450 nm. Peak identification was verified by retention times and spikes with external standards. Standard curves were constructed (R(2)>0.99) to allow for sample quantification. Recovery of the saponification and extraction was demonstrated via analysis of spiked samples. Also, the accuracy of results of four soybeans using the described saponification and HPLC analytical method was validated against existing methods. This method offers a more efficient alternative to individual methods for quantifying lutein, tocopherols and sterols in soybeans. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Application of Pattern Recognition Method for Color Assessment of Oriental Tobacco based on HPLC of Polyphenols

    Directory of Open Access Journals (Sweden)

    Dagnon S

    2014-12-01

    Full Text Available The color of Oriental tobaccos was organoleptically assayed, and high performance liquid chromatography (HPLC of polyphenols was performed. The major tobacco polyphenols (chlorogenic acid, its isomers, and rutin, as well as scopoletin and kaempferol-3-rutinoside were quantified. HPLC polyphenol profiles were processed by pattern recognition method (PRM, and the values of indexes of similarity (Is,% between the cultivars studied were determined. It was shown that data from organoleptic color assessment and from PRM based on HPLC profiles of polyphenols of the cultivars studied are largely compatible. Hence, PRM can be suggested as an additional tool for objective color evaluation and classification of Oriental tobacco.

  11. HPLC-DAD stability indicating determination of nizatidine in bulk and capsules dosage form

    Directory of Open Access Journals (Sweden)

    Tarek S. Belal

    2013-12-01

    Full Text Available This work describes the stability-indicating determination of the H2-receptor antagonist nizatidine in its bulk and capsules dosage form using high performance liquid chromatography coupled with diode array detector (HPLC-DAD. The developed method involved the use of Thermo Hypersil BDS-C8 (4.6 × 250 mm, 5 μm particle size column and a mobile phase composed of 0.05 M phosphoric acid and acetonitrile (50:50, v/v. The mobile phase was pumped at a flow rate of 1 mL/min. Quantification of nizatidine was based on measuring its peak area at 320 nm. The retention time for nizatidine was about 3.61 min. The reliability and analytical performance of the proposed HPLC procedure were statistically validated with respect to linearity, range, precision, accuracy, specificity, robustness, detection and quantification limits. Calibration curve of nizatidine was linear in the range of 5–50 μg/mL with correlation coefficient >0.9999. The drug was subjected to forced-degradation conditions of acidic and basic hydrolysis, oxidation, dry heat and UV photolysis where it showed considerable degradation in basic and oxidative conditions. The proposed method proved to be specific and stability-indicating by resolution of the drug from its forced-degradation products. The validated HPLC method was applied to the analysis of nizatidine in capsules dosage form where it was quantified with recoveries not less than 98.2%. Assay results were statistically compared to USP 2011 pharmacopeial method where no significant difference was observed between the proposed and reference methods.

  12. Development of a rapid, simple and sensitive HPLC-FLD method for determination of rhodamine B in chili-containing products.

    Science.gov (United States)

    Qi, Ping; Lin, Zhihao; Li, Jiaxu; Wang, ChengLong; Meng, WeiWei; Hong, Hong; Zhang, Xuewu

    2014-12-01

    In this work, a simple, rapid and sensitive analytical method for the determination of rhodamine B in chili-containing foodstuffs is described. The dye is extracted from samples with methanol and analysed without further cleanup procedure by high-performance liquid chromatography (HPLC) coupled to fluorescence detection (FLD). The influence of matrix fluorescent compounds (capsaicin and dihydrocapsaicin) on the analysis was overcome by the optimisation of mobile-phase composition. The limit of determination (LOD) and limit of quantification (LOQ) were 3.7 and 10 μg/kg, respectively. Validation data show a good repeatability and within-lab reproducibility with relative standard deviations rhodamine B in foodstuffs. This method is suitable for the routine analysis of rhodamine B due to its sensitivity, simplicity, reasonable time and cost. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. An HPLC-DAD method to quantification of main phenolic compounds from leaves of Cecropia species

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Geison M.; Ortmann, Caroline F.; Schenkel, Eloir P.; Reginatto, Flavio H., E-mail: freginatto@hotmail.co [Universidade Federal de Santa Catarina (UFSC), Florianopolis (Brazil). Centro de Ciencias da Saude. Dept. de Ciencias Farmaceuticas

    2011-07-01

    An efficient and reproducible HPLC-DAD method was developed and validated for the simultaneous quantification of major compounds (chlorogenic acid, isoorientin, orientin and isovitexin) present in the leaves of two Cecropia species, C. glaziovii and C. pachystachya. From the leaves of C. glaziovii and C. pachystachya were isolated the C-glycosylflavones isoorientin and isovitexin and identified on both species chlorogenic acid (3-O-caffeoylquinic acid) and the O-glycosylflavonol isoquercitrin. The C-glycosylflavone orientin was isolated only from C. pachystachya. Chlorogenic acid was the major compound in both species (11.1 mg g{sup -1} of extract of C. glaziovii and 27.2 mg g{sup -1} of extract of C. pachystachya) and for the flavonoids quantified, isovitexin was the main C-glycosylflavonoid for C. glaziovii (4.6 mg g{sup -1} of extract) and isoorientin the main one for C. pachystachya (17.3 mg g{sup -1} of extract). (author)

  14. An HPLC-DAD method to quantification of main phenolic compounds from leaves of Cecropia species

    International Nuclear Information System (INIS)

    Costa, Geison M.; Ortmann, Caroline F.; Schenkel, Eloir P.; Reginatto, Flavio H.

    2011-01-01

    An efficient and reproducible HPLC-DAD method was developed and validated for the simultaneous quantification of major compounds (chlorogenic acid, isoorientin, orientin and isovitexin) present in the leaves of two Cecropia species, C. glaziovii and C. pachystachya. From the leaves of C. glaziovii and C. pachystachya were isolated the C-glycosylflavones isoorientin and isovitexin and identified on both species chlorogenic acid (3-O-caffeoylquinic acid) and the O-glycosylflavonol isoquercitrin. The C-glycosylflavone orientin was isolated only from C. pachystachya. Chlorogenic acid was the major compound in both species (11.1 mg g -1 of extract of C. glaziovii and 27.2 mg g -1 of extract of C. pachystachya) and for the flavonoids quantified, isovitexin was the main C-glycosylflavonoid for C. glaziovii (4.6 mg g -1 of extract) and isoorientin the main one for C. pachystachya (17.3 mg g -1 of extract). (author)

  15. Optimization and validation of high-performance liquid chromatography method for analyzing 25-desacetyl rifampicin in human urine

    Science.gov (United States)

    Lily; Laila, L.; Prasetyo, B. E.

    2018-03-01

    A selective, reproducibility, effective, sensitive, simple and fast High-Performance Liquid Chromatography (HPLC) was developed, optimized and validated to analyze 25-Desacetyl Rifampicin (25-DR) in human urine which is from tuberculosis patient. The separation was performed by HPLC Agilent Technologies with column Agilent Eclipse XDB- Ci8 and amobile phase of 65:35 v/v methanol: 0.01 M sodium phosphate buffer pH 5.2, at 254 nm and flow rate of 0.8ml/min. The mean retention time was 3.016minutes. The method was linear from 2–10μg/ml 25-DR with a correlation coefficient of 0.9978. Standard deviation, relative standard deviation and coefficient variation of 2, 6, 10μg/ml 25-DR were 0-0.0829, 03.1752, 0-0.0317%, respectively. The recovery of 5, 7, 9μg/ml25-DR was 80.8661, 91.3480 and 111.1457%, respectively. Limits of detection (LoD) and quantification (LoQ) were 0.51 and 1.7μg/ml, respectively. The method has fulfilled the validity guidelines of the International Conference on Harmonization (ICH) bioanalytical method which includes parameters of specificity, linearity, precision, accuracy, LoD, and LoQ. The developed method is suitable for pharmacokinetic analysis of various concentrations of 25-DR in human urine.

  16. Quantitation of polycyclic aromatic hydrocarbons (PAH4) in cocoa and chocolate samples by an HPLC-FD method.

    Science.gov (United States)

    Raters, Marion; Matissek, Reinhard

    2014-11-05

    As a consequence of the PAH4 (sum of four different polycyclic aromatic hydrocarbons, named benzo[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[a]pyrene) maximum levels permitted in cocoa beans and derived products as of 2013, an high-performance liquid chromatography with fluorescence detection method (HPLC-FD) was developed and adapted to the complex cocoa butter matrix to enable a simultaneous determination of PAH4. The resulting analysis method was subsequently successfully validated. This method meets the requirements of Regulation (EU) No. 836/2011 regarding analysis methods criteria for determining PAH4 and is hence most suitable for monitoring the observance of the maximum levels applicable under Regulation (EU) No. 835/2011. Within the scope of this work, a total of 218 samples of raw cocoa, cocoa masses, and cocoa butter from several sample years (1999-2012), of various origins and treatments, as well as cocoa and chocolate products were analyzed for the occurrence of PAH4. In summary, it is noted that the current PAH contamination level of cocoa products can be deemed very slight overall.

  17. Validation for The Quantification of Andrographolide Isolated from Andrographis paniculata Nees Plant Using HPLC

    Directory of Open Access Journals (Sweden)

    Yandi Syukri

    2015-12-01

    Full Text Available The aim of study was to develop quantitative analysis of isolated andrographolide from Andrographis paniculata and different solvent for prelimenary studies to preperation Self Nano Emulsifying Drug Delivery System (SNEDDS using HPLC. The separation was acquired on Sunfire C18 column with an isocratic mixture of methanol and water at a ratio of 6:4, v/v as a mobile phase. The method to determine the content of isolated andrographolide showed an adequate precision, with a RSD smaller than 1%. The accuracy was analyzed by adding the standard andrographolide, and good recovery values were obtained for all concentrations used. The HPLC method developed in this study showed specificity and selectivity with linearity in the working range and good precision and accuracy, making it very suitable for the quantification of isolated andrographolide. Compared to the standard, the purity of the isolated andrographolide was 95.74 ± 0.29 %. Prelimenary study to determined the highest solubility of isolated andrographolide in oil, surfactant and co-surfactant phases for preperation of SNEDDS were obtained 1.226 ± 0.009 of Capryol-90, 2.965 ± 0.014 of tween 20, and  6.074 ± 0.101 mg mL-1 of PEG 400, respectively. Conclusion, this method suitable used to determination solublity of isolated andrographolide for preperation SNEDDS.

  18. Analysis of the extracts of Isatis tinctoria by new analytical approaches of HPLC, MS and NMR.

    Science.gov (United States)

    Zhou, Jue; Qu, Fan

    2011-01-01

    The methods of extraction, separation and analysis of alkaloids and indole glucosinolates (GLs) ofIsatis tinctoria were reviewed. Different analytical approaches such as High-pressure Liquid Chromatography (HPLC), Liquid Chromatography with Electrospray Ionization Mass Spectrometry (LC/ESI/MS), Electrospray Ionization Time-Of-Flight Mass Spectrometry (ESI-TOF-MS), and Nuclear Magnetic Resonance (NMR) were used to validate and identity of these constituents. These methods provide rapid separation, identification and quantitative measurements of alkaloids and GLs of Isatis tinctoria. By connection with different detectors to HPLC such as PDA, ELSD, ESI- and APCI-MS in positive and negative ion modes, complicated compounds could be detected with at least two independent detection modes. The molecular formula can be derived in a second step of ESI-TOF-MS data. But for some constituents, UV and MS cannot provide sufficient structure identification. After peak purification, NMR by semi-preparative HPLC can be used as a complementary method.

  19. Validated HPLC method for determination of sennosides A and B in senna tablets.

    Science.gov (United States)

    Sun, Shao Wen; Su, Hsiu Ting

    2002-07-31

    This study developed an efficient and reliable ion-pair liquid chromatographic method for quantitation of sennosides A and B in commercial senna tablets. Separation was conducted on a Hypersil C 18 column (250 x 4.6 mm, 5 microm) at a temperature of 40 degrees C, using a mixture of 0.1 M acetate buffer (pH 6.0) and acetonitrile (70:30, v/v) containing 5 mM tetrahexylammonium bromide as mobile phase. Sennosides A and B were completely separated from other constituents within 14 min. The developed method was validated. Both run-to-run repeatability (n=10) and day-to-day reproducibility (n=3) of peak area were below 0.4% RSD. Linearity of peak area was tested in the range 30-70 microg/ml (r>0.9997). Accuracy was assessed with recovery and the recoveries for sennosides A and B were 101.73+/-1.30% and 101.81+/-2.18% (n=3 x 6), respectively. Robustness of the analytical method was tested using a three-leveled Plackett-Burman design in which 11 factors were assessed with 23 experiments. Eight factors (column, concentration of ion pair reagent, % of organic modifier (acetonitrile), buffer pH, column temperature, flow rate, time constant and detection wavelength) were investigated in a specified range above and below the nominal method conditions. It was found that: (1) column and % acetonitrile affected significantly resolution and retention time, (2) column, % acetonitrile, column temperature, flow rate and time constant affected significantly the plate number of sennoside A, and (3) column and time constant affected significantly the tailing factor.

  20. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma

    Directory of Open Access Journals (Sweden)

    Ana Paula Barbosa do Carmo

    Full Text Available Abstract INTRODUCTION: Primaquine (PQ diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV analysis of PQ in the blood plasma was developed and validated. METHODS: After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80 (45:55 as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD and quantification (LOQ limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral PQ diphosphate. RESULTS: By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. CONCLUSIONS: The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  1. Development and application of a HPLC method for eight sunscreen agents in suncare products.

    Science.gov (United States)

    Peruchi, L M; Rath, S

    2012-06-01

    This work describes the development, validation and application of a simple and fast high-performance liquid chromatography-with diode array dectection (HPLC-DAD) method for the determination of eight sunscreen agents: benzophenone-3, octocrylene, ethylhexyl methoxycinnamate, ethylhexyl salicylate, homosalate (used in two isomeric forms), butyl methoxydibenzoylmethane, 4-methylbenzylidene camphor and ethylhexyl dimethyl PABA in sunscreen formulations. The separation of the eight sunscreen compounds was achieved using an ACE C18 column (250 × 4.6 mm, 5 μm), with a column temperature 20°C, and a mobile phase of 88 : 12 (v/v) methanol-water with isocratic elution. Column temperature strongly influences the retention time and resolution of the compounds. The flow rate was 1.0 mL min(-1) and quantitation was performed by external calibration at the maximum wavelength of each compound. The sample preparation was simple and consisted basically of sample dilution with methanol, centrifugation and filtration in syringe filters before quantitation. Total run time was 18 min. The method was validated according to the parameters: linear range, linearity, selectivity, intra-day and inter-day precision and accuracy. Ten samples of sunscreen emulsions commercially available in Brazil (SPF 30) from different manufacturers were analysed using the proposed method. The number of the sunscreen agents varied between one and five in a single sample. The concentrations of all compounds were in the range of 0.9-10% (w/w) and were in accordance with the current Brazilian legislation. © 2012 The Authors. ICS © 2012 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  2. Chemometric approach for development, optimization, and validation of different chromatographic methods for separation of opium alkaloids.

    Science.gov (United States)

    Acevska, J; Stefkov, G; Petkovska, R; Kulevanova, S; Dimitrovska, A

    2012-05-01

    The excessive and continuously growing interest in the simultaneous determination of poppy alkaloids imposes the development and optimization of convenient high-throughput methods for the assessment of the qualitative and quantitative profile of alkaloids in poppy straw. Systematic optimization of two chromatographic methods (gas chromatography (GC)/flame ionization detector (FID)/mass spectrometry (MS) and reversed-phase (RP)-high-performance liquid chromatography (HPLC)/diode array detector (DAD)) for the separation of alkaloids from Papaver somniferum L. (Papaveraceae) was carried out. The effects of various conditions on the predefined chromatographic descriptors were investigated using chemometrics. A full factorial linear design of experiments for determining the relationship between chromatographic conditions and the retention behavior of the analytes was used. Central composite circumscribed design was utilized for the final method optimization. By conducting the optimization of the methods in very rational manner, a great deal of excessive and unproductive laboratory research work was avoided. The developed chromatographic methods were validated and compared in line with the resolving power, sensitivity, accuracy, speed, cost, ecological aspects, and compatibility with the poppy straw extraction procedure. The separation of the opium alkaloids using the GC/FID/MS method was achieved within 10 min, avoiding any derivatization step. This method has a stronger resolving power, shorter analysis time, better cost/effectiveness factor than the RP-HPLC/DAD method and is in line with the "green trend" of the analysis. The RP-HPLC/DAD method on the other hand displayed better sensitivity for all tested alkaloids. The proposed methods provide both fast screening and an accurate content assessment of the six alkaloids in the poppy samples obtained from the selection program of Papaver strains.

  3. A novel HPLC method for separation of uranium from thorium using BEHSA modified semi preparative support

    International Nuclear Information System (INIS)

    Raju, Ch.Siva Kesava; Subramanian, M.S.; Sivaraman, N.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2006-01-01

    The determination of uranium and thorium is of great importance with respect to nuclear industry and environmental samples. High performance liquid chromatography (HPLC) has revolutionized as a powerful separation and analytical tool in the field of chemistry, biology, medicine, pharmacy, chemical technology, food science and many more. The major advantages of HPLC are its ability to provide rapid, high performance separations and extending the separations range from laboratory scale to preparative scale purification. HPLC became powerful technique for the separation of uranium and thorium. These methods were widely employed in applications such as separation of uranium from fission products and for the measurement of number of fissions as in the case of burn-up measurements on nuclear reactor fuels

  4. Simultaneous determination of domperidone and Itopride in pharmaceuticals and human plasma using RP-HPLC/UV detection: Method development, validation and application of the method in in-vivo evaluation of fast dispersible tablets.

    Science.gov (United States)

    Khan, Amjad; Iqbal, Zafar; Khadra, Ibrahim; Ahmad, Lateef; Khan, Abad; Khan, Muhammad Imran; Ullah, Zia; Ismail

    2016-03-20

    Domperidone and Itopride are pro-kinetic agents, regulating the gastric motility and are commonly prescribed as anti emetic drugs. In the present study a simple, rapid and sensitive RP-HPLC/UV method was developed for simultaneous determination of Domperidone and Itopride in pharmaceutical samples and human plasma, using Tenofavir as internal standard. Experimental conditions were optimized and method was validated according to the standard guidelines. Combination of water (pH 3.0) and acetonitrile (65:35 v/v) was used as mobile phase, pumped at the flow rate of 1.5 ml/min. Detector wavelength was set at 210 nm and column oven temperature was 40oC. Unlike conventional liquid-liquid extraction, simple precipitation technique was applied for drug extraction from human plasma using acetonitrile for deprotienation. The method showed adequate separation of both the analytes and best resolution was achieved using Hypersil BDS C8 column (150 mm × 4.6 mm, 5 μm). The method was quite linear in the range of 20-600 ng/ml. Recovery of the method was 92.31% and 89.82% for Domperidone and Itopride, respectively. Retention time of both the analytes and internal standard was below 15 min. The lower limit of detection (LLOD) and lower limit of quantification (LLOQ) for Domperidone were 5 and 10 ng/ml while for Itopride was 12 and 15 ng/ml, respectively. The developed method was successfully applied for in-vivo analysis of fast dispersible tablets of Domperidone in healthy human volunteer. The proposed method was a part of formulation development study and was efficiently applied for determination of the two drugs in various pharmaceutical products and human plasma. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Validation of an HPLC method for the determination of fleroxacin and its photo-degradation products in pharmaceutical forms.

    Science.gov (United States)

    Djurdjevic, Predrag; Laban, Aleksandra; Jelikic-Stankov, Milena

    2004-01-01

    HPLC determination of fleroxacin in dosage forms was carried out using either reversed-phase column YMC pack ODS-AQ or Supelco LC Hisep shielded hydrophobic phase column, with UV detection at 280 nm. The mobile phase for ODS column consisted of 50:50:0.5 v/v/v and for Hisep column 15:85:0.5 v/v/v acetonitrile-water-triethylamine. The pH of the mobile phase was adjusted to 6.30 for ODS column and to 6.85 for Hisep column, with H3PO4. Linear response was obtained in the concentration range of fleroxacin between 0.01 and 1.30 micrograms/mL. Detection limit was 4.8 ng/mL. Recovery test in the determination of fleroxacin in "Quinodis" tablets (Hoffmann La Roche, nominal mass 400 or 200 mg) was 98-101% for both columns. The effect of the composition and pH of the mobile phase on spectra, retention time and dissociation constants of fleroxacin was discussed. The proposed method could be also used for separation of the photo-degradation products of fleroxacin. Ten degradation products were separated on the ODS-AQ column, thus confirming the suitability of the proposed method for stability study of fleroxacin in pharmaceuticals.

  6. Improved HPLC method for the determination of curcumin, demethoxycurcumin, and bisdemethoxycurcumin.

    Science.gov (United States)

    Jayaprakasha, Guddadarangavvanahally K; Jagan Mohan Rao, Lingamullu; Sakariah, Kunnumpurath K

    2002-06-19

    Commercially available curcumin, a bright orange-yellow color pigment of turmeric, consists of a mixture of three curcuminoids, namely, curcumin, demethoxycurcumin, and bisdemethoxycurcumin. These were isolated by column chromatography and identified by spectroscopic studies. The purity of the curcuminoids was analyzed by an improved HPLC method. HPLC separation was performed on a C(18) column using three solvents, methanol, 2% AcOH, and acetonitrile, with detection at 425 nm. Four different commercially available varieties of turmeric, namely, Salem, Erode, Balasore, and local market samples, were analyzed to detect the percentage of these three curcuminoids. The percentages of curcumin, demethoxycurcumin, and bisdemethoxycurcumin as estimated using their calibration curves were found to be 1.06 +/- 0.061 to 5.65 +/- 0.040, 0.83 +/- 0.047 to 3.36 +/- 0.040, and 0.42 +/- 0.036 to 2.16 +/- 0.06, respectively, in four different samples. The total percentages of curcuminoids are 2.34 +/- 0.171 to 9.18 +/- 0.232%.

  7. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma.

    Science.gov (United States)

    Carmo, Ana Paula Barbosa do; Borborema, Manoella; Ribeiro, Stephan; De-Oliveira, Ana Cecilia Xavier; Paumgartten, Francisco Jose Roma; Moreira, Davyson de Lima

    2017-01-01

    Primaquine (PQ) diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV ) analysis of PQ in the blood plasma was developed and validated. After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm) as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80) (45:55) as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD) and quantification (LOQ) limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral) PQ diphosphate. By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  8. A VALIDATED STABILITY INDICATED RP-HPLC METHOD FOR DUTASTERIDE

    OpenAIRE

    D. Pavan Kumar a, b *, Naga Jhansi a, G. Srinivasa Rao b, Kirti Kumar Jain a

    2018-01-01

    ABSTRACT A Simple, Stability indicating, Isocratic, reverse phase High Performance Liquid Chromatographic (RPLC) related substance method was developed for Dutasteride in API. This method separates the impurities which are co-eluting in the pharmacopeia method. Successful separation of degradation impurities and synthetic impurities was achieved by YMC Triat phenyl column. Chromatographic was carried out on YMC Triat phenyl (150 X 4.6 mm, 3.0µm) column using 0.01M Potassium Dihydrogen Pho...

  9. Inter-laboratory validation of an inexpensive streamlined method to measure inorganic arsenic in rice grain.

    Science.gov (United States)

    Chaney, Rufus L; Green, Carrie E; Lehotay, Steven J

    2018-05-04

    With the establishment by CODEX of a 200 ng/g limit of inorganic arsenic (iAs) in polished rice grain, more analyses of iAs will be necessary to ensure compliance in regulatory and trade applications, to assess quality control in commercial rice production, and to conduct research involving iAs in rice crops. Although analytical methods using high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) have been demonstrated for full speciation of As, this expensive and time-consuming approach is excessive when regulations are based only on iAs. We report a streamlined sample preparation and analysis of iAs in powdered rice based on heated extraction with 0.28 M HNO 3 followed by hydride generation (HG) under control of acidity and other simple conditions. Analysis of iAs is then conducted using flow-injection HG and inexpensive ICP-atomic emission spectroscopy (AES) or other detection means. A key innovation compared with previous methods was to increase the acidity of the reagent solution with 4 M HCl (prior to reduction of As 5+ to As 3+ ), which minimized interferences from dimethylarsinic acid. An inter-laboratory method validation was conducted among 12 laboratories worldwide in the analysis of six shared blind duplicates and a NIST Standard Reference Material involving different types of rice and iAs levels. Also, four laboratories used the standard HPLC-ICP-MS method to analyze the samples. The results between the methods were not significantly different, and the Horwitz ratio averaged 0.52 for the new method, which meets official method validation criteria. Thus, the simpler, more versatile, and less expensive method may be used by laboratories for several purposes to accurately determine iAs in rice grain. Graphical abstract Comparison of iAs results from new and FDA methods.

  10. Simultaneous Determination of 5 Flavonoids and 7 Saponins for Quality Control of Traditional Chinese Medicine Preparation Xinnaoshutong Capsule Using HPLC-VWD-ELSD

    Directory of Open Access Journals (Sweden)

    Jin Li

    2017-01-01

    Full Text Available Xinnaoshutong capsule (XC is a traditional Chinese prescription derived from the ripe fruit of Tribulus terrestris L. (TT. Although XC has long been considered as an important herbal medicine, no analytical method of marker compounds for quality assessment is registered in the Chinese Pharmacopoeia. A simple analytical method of twelve marker components was developed and validated by HPLC-VWD-ELSD method. Chromatographic separation by HPLC was carried out on a Hedera ODS 2 column (4.6 × 250 mm, 5 μm by gradient elution with acetonitrile-water (0.1% formic acid as the mobile phase. Various extraction conditions were optimized to achieve twelve marker compounds with faster extraction and higher recovery. The analytical condition was then validated in terms of the linearity, accuracy and precision, repeatability, and stability. The twelve markers were successfully quantified in 30 batches of commercial samples. The developed HPLC-VWD-ELSD could be used as a rapid and reliable way in the assessment and quality control of XC and TT.

  11. Validation of a high performance liquid chromatography method for the stabilization of epigallocatechin gallate.

    Science.gov (United States)

    Fangueiro, Joana F; Parra, Alexander; Silva, Amélia M; Egea, Maria A; Souto, Eliana B; Garcia, Maria L; Calpena, Ana C

    2014-11-20

    Epigallocatechin gallate (EGCG) is a green tea catechin with potential health benefits, such as anti-oxidant, anti-carcinogenic and anti-inflammatory effects. In general, EGCG is highly susceptible to degradation, therefore presenting stability problems. The present paper was focused on the study of EGCG stability in HEPES (N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid) medium regarding the pH dependency, storage temperature and in the presence of ascorbic acid a reducing agent. The evaluation of EGCG in HEPES buffer has demonstrated that this molecule is not able of maintaining its physicochemical properties and potential beneficial effects, since it is partially or completely degraded, depending on the EGCG concentration. The storage temperature of EGCG most suitable to maintain its structure was shown to be the lower values (4 or -20 °C). The pH 3.5 was able to provide greater stability than pH 7.4. However, the presence of a reducing agent (i.e., ascorbic acid) was shown to provide greater protection against degradation of EGCG. A validation method based on RP-HPLC with UV-vis detection was carried out for two media: water and a biocompatible physiological medium composed of Transcutol®P, ethanol and ascorbic acid. The quantification of EGCG for purposes, using pure EGCG, requires a validated HPLC method which could be possible to apply in pharmacokinetic and pharmacodynamics studies. Copyright © 2014. Published by Elsevier B.V.

  12. A simple HPLC method for the determination of halcinonide in lipid nanoparticles: development, validation, encapsulation efficiency, and in vitro drug permeation

    Directory of Open Access Journals (Sweden)

    Clarissa Elize Lopes

    2017-06-01

    Full Text Available ABSTRACT Halcinonide is a high-potency topical glucocorticoid used for skin inflammation treatments that presents toxic systemic effects. A simple and quick analytical method to quantify the amount of halcinonide encapsulated into lipid nanoparticles, such as polymeric lipid-core nanoparticles and solid lipid nanoparticles, was developed and validated regarding the drug's encapsulation efficiency and in vitro permeation. The development and validation of the analytical method were carried out using the high performance liquid chromatography with the UV detection at 239 nm. The validation parameters were specificity, linearity, precision and accuracy, limits of detection and quantitation, and robustness. The method presented an isocratic flow rate of 1.0 mL.min-1, a mobile phase methanol:water (85:15 v/v, and a retention time of 4.21 min. The method was validated according to international and national regulations. The halcinonide encapsulation efficiency in nanoparticles was greater than 99% and the in vitro drug permeation study showed that less than 9% of the drug permeated through the membrane, indicating a nanoparticle reservoir effect, which can reduce the halcinonide's toxic systemic effects. These studies demonstrated the applicability of the developed and validated analytical method to quantify halcinonide in lipid nanoparticles.

  13. Preparation and determination of desethylamiodarone in dog lung by HPLC-MS.

    Science.gov (United States)

    Hong, Liu Xue; Ying, Yang Chuan; Lei, Zheng; Chen, Guo Rui

    2011-11-01

    A novel method was developed for the preparation and determination of desethylamiodarone in dog lung by high-performance liquid chromatography (HPLC) with amiodarone as a standard. The selected dog was orally given amiodarone, then executed and the active metabolite desethylamiodirone in lung tissue was isolated, concentrated and purified by Waters C18 column (25 mm x 250 mm, 10 microm) with mobile phase of acetonitrile-100 mmol/L acetic acid containing 15 mmol/L diethylamine (55:45 v/v) at a flow rate of 10.0 mL/min. Hypersil ODS2 column (4.6 mm x 250 mm 5 microm) was used to analyze amiodarone and desethylamiodarone, with the same mobile phase at a flow rate of 1.0 mL/min, the detection wavelength was 237.5 nm. Atmosperic pressure electronic spray ionization (AP-ESI) and ion mass spectral (m/z) of 618.1(M + H) were selected to validate desethylamiodarone. The f(i) of desethylamiodarone and amiodarone were 1.04 +/- 0.02 and 1.020 +/- 0.01, respectively. It indicated that desethylamiodarone can be separated and purified by preparational HPLC after Mass Spectrometry (MS) validation and quantified according to f(i) of amiodarone indirectly. The proposed method enables the preparation and determination of desethylamiodarone in dog lung successfully.

  14. Fingerprint analysis of polysaccharides from different Ganoderma by HPLC combined with chemometrics methods.

    Science.gov (United States)

    Sun, Xiaomei; Wang, Haohao; Han, Xiaofeng; Chen, Shangwei; Zhu, Song; Dai, Jun

    2014-12-19

    A fingerprint analysis method has been developed for characterization and discrimination of polysaccharides from different Ganoderma by high performance liquid chromatography (HPLC) coupled with chemometrics means. The polysaccharides were extracted under ultrasonic-assisted condition, and then partly hydrolyzed with trifluoroacetic acid. Monosaccharides and oligosaccharides in the hydrolyzates were subjected to pre-column derivatization with 1-phenyl-3-methyl-5-pyrazolone and HPLC analysis, which will generate unique fingerprint information related to chemical composition and structure of polysaccharides. The peak data were imported to professional software in order to obtain standard fingerprint profiles and evaluate similarity of different samples. Meanwhile, the data were further processed by hierarchical cluster analysis and principal component analysis. Polysaccharides from different parts or species of Ganoderma or polysaccharides from the same parts of Ganoderma but from different geographical regions or different strains could be differentiated clearly. This fingerprint analysis method can be applied to identification and quality control of different Ganoderma and their products. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. HPLC: Early and Recent Perspectives.

    Science.gov (United States)

    Karger, Barry L.

    1997-01-01

    Provides a perspective on what it was like in the early days of high-performance liquid chromatography (HPLC) and several of the key developments. Focuses on the advances in HPLC generally, and more specifically for the biological sciences, that were necessary for the method to reach the preeminent stage of today. Contains 20 references. (JRH)

  16. A simple method for the quantitative analysis of tyrosol by hplc in liquid Czapek Cultures from endophytic fungi

    International Nuclear Information System (INIS)

    Guimaraes, Denise O.; Pupo, Monica T.; Borges, Keyller B.; Bonato, Pierina S.

    2009-01-01

    Tyrosol is a possible quorum sensing molecule in endophytic fungi. High-performance liquid chromatography (HPLC) coupled with diode array detector (DAD) was used for the analysis of tyrosol in liquid Czapek fungal cultures. The optimized conditions were gradient mobile phase, in linear mode, consisting initially of acetonitrile/water (1:9 v/v) and increasing up to acetonitrile (100%) in 30 minutes at a flow rate of 1 mL min -1 . The column used was a Zorbax ODS (250 x 4.6 mm, 5 μm) at 25 deg C. Liquid-liquid extraction of 0.5 mL medium (pH 7.0) with ethyl acetate and injection of 20 μL after solvent evaporation under air flow gave good results. Some validation parameters obtained were: linearity 0.0125-5.0 μg mL -1 medium (r = 0.9967), quantification limit of 0.0125 μg mL -1 medium, %CV (precision) and %E (accuracy) bellow 15% and recovery around 80%. Therefore, the developed method presented satisfactory validation parameters and it was efficient for the analysis of tyrosol in Czapek medium. (author)

  17. Chromatographic Analysis of a Multicomponent Mixture of B1, B6, B12, Benfotiamine, and Diclofenac; Part I: HPLC and UPLC Methods for the Simultaneous Quantification of These Five Components in Tablets and Capsules.

    Science.gov (United States)

    Fayed, Ahmed Salah; Hegazy, Maha Abdel-Monem; Wahab, Nada Sayed Abdel

    2016-11-01

    New, simple, highly sensitive, precise, and accurate gradient reversed-phase chromatographic methods were developed using HPLC and ultra-HPLC (UPLC) systems for the determination of five components, namely thiamine, pyridoxine, cyanocobalamin, benfotiamine, and diclofenac in tablets and capsules. The methods were compared for their efficiency in the separation and determination of these five compounds using two different C18 columns (250 × 4.6 mm, 5 μm; and 100 × 4.6 mm, 2.6 μm) for HPLC and UPLC, respectively. Chromatographic separation was performed with a mobile phase containing acetonitrile and 0.025 M phosphate buffer (pH 3.5), with a gradient program and a flow rate of 1.5 and 1.0 mL/min for both methods, respectively. The methods were validated according to International Conference on Harmonization guidelines. Linearity was achieved in the range of 5.00 to 150.00 μg/mL for each of the five compounds. Ruggedness and intermediate precision were confirmed by different analysts on different columns on different days. Moreover, the components were subjected to an accelerated stability study under acidic, alkaline, and oxidative stress conditions and no interfering peaks were observed. The five compounds were efficiently separated in <20 min by HPLC, whereas for UPLC, separation was achieved in <8 min, which dramatically decreased the consumption of organic solvents.

  18. Development of Isocratic RP-HPLC Method for Separation and Quantification of L-Citrulline and L-Arginine in Watermelons

    Directory of Open Access Journals (Sweden)

    Rasdin Ridwan

    2018-01-01

    Full Text Available Watermelons (Citrullus lanatus are known to have sufficient amino acid content. In this study, watermelons grown and consumed in Malaysia were investigated for their amino acid content, L-citrulline and L-arginine, by the isocratic RP-HPLC method. Flesh and rind watermelons were juiced, and freeze-dried samples were used for separation and quantification of L-citrulline and L-arginine. Three different mobile phases, 0.7% H3P04, 0.1% H3P04, and 0.7% H3P04 : ACN (90 : 10, were tested on two different columns using Zorbax Eclipse XDB-C18 and Gemini C18 with a flow rate of 0.5 mL/min and a detection wavelength at 195 nm. Efficient separation with reproducible resolution of L-citrulline and L-arginine was achieved using 0.1% H3P04 on the Gemini C18 column. The method was validated and good linearity of L-citrulline and L-arginine was obtained with R2 = 0.9956, y=0.1664x+2.4142 and R2=0.9912, y=0.4100x+3.4850, respectively. L-citrulline content showed the highest concentration in red watermelon of flesh and rind juice extract (43.81 mg/g and 45.02 mg/g, whereas L-arginine concentration was lower than L-citrulline, ranging from 3.39 to 11.14 mg/g. The isocratic RP-HPLC method with 0.1% H3P04 on the Gemini C18 column proved to be efficient for separation and quantification of L-citrulline and L-arginine in watermelons.

  19. A systematic approach to the accurate quantification of selenium in serum selenoalbumin by HPLC-ICP-MS

    International Nuclear Information System (INIS)

    Jitaru, Petru; Goenaga-Infante, Heidi; Vaslin-Reimann, Sophie; Fisicaro, Paola

    2010-01-01

    In this paper, two different methods are for the first time systematically compared for the determination of selenium in human serum selenoalbumin (SeAlb). Firstly, SeAlb was enzymatically hydrolyzed and the resulting selenomethionine (SeMet) was quantified using species-specific isotope dilution (SSID) with reversed phase-HPLC (RP-HPLC) hyphenated to (collision/reaction cell) inductively coupled plasma-quadrupole mass spectrometry (CRC ICP-QMS). In order to assess the enzymatic hydrolysis yield, SeAlb was determined as an intact protein by affinity-HPLC (AF-HPLC) coupled to CRC ICP-QMS. Using this approach, glutathione peroxidase (GPx) and selenoprotein P (SelP) (the two selenoproteins present in serum) were also determined within the same chromatographic run. The levels of selenium associated with SeAlb in three serum materials, namely BCR-637, Seronorm level 1 and Seronorm level 2, obtained using both methods were in a good agreement. Verification of the absence of free SeMet, which interferes with the SeAlb determination (down to the amino acid level), in such materials was addressed by analyzing the fraction of GPx, partially purified by AF-HPLC, using RP-HPLC (GPx only) and size exclusion-HPLC (SE-HPLC) coupled to CRC ICP-QMS. The latter methodology was also used for the investigation of the presence of selenium species other than the selenoproteins in the (AF-HPLC) SelP and SeAlb fractions; the same selenium peaks were detected in both control and BCR-637 serum with a difference in age of ca. 12 years. It is also for the first time that the concentrations of selenium associated with SeAlb, GPx and SelP species in such commercially available serums (only certified or having indicative levels of total selenium content) are reported. Such indicative values can be used for reference purposes in future validation of speciation methods for selenium in human serum and/or inter-laboratory comparisons.

  20. A systematic approach to the accurate quantification of selenium in serum selenoalbumin by HPLC-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Jitaru, Petru, E-mail: Petru.Jitaru@lne.fr [Laboratoire National de Metrologie et d' Essais (LNE), Department of Biomedical and Inorganic Chemistry, 1 rue Gaston Boissier, 75015 Paris (France); Goenaga-Infante, Heidi [LGC Limited, Queens Road, Teddington, TW11 OLY, Middlesex (United Kingdom); Vaslin-Reimann, Sophie; Fisicaro, Paola [Laboratoire National de Metrologie et d' Essais (LNE), Department of Biomedical and Inorganic Chemistry, 1 rue Gaston Boissier, 75015 Paris (France)

    2010-01-11

    In this paper, two different methods are for the first time systematically compared for the determination of selenium in human serum selenoalbumin (SeAlb). Firstly, SeAlb was enzymatically hydrolyzed and the resulting selenomethionine (SeMet) was quantified using species-specific isotope dilution (SSID) with reversed phase-HPLC (RP-HPLC) hyphenated to (collision/reaction cell) inductively coupled plasma-quadrupole mass spectrometry (CRC ICP-QMS). In order to assess the enzymatic hydrolysis yield, SeAlb was determined as an intact protein by affinity-HPLC (AF-HPLC) coupled to CRC ICP-QMS. Using this approach, glutathione peroxidase (GPx) and selenoprotein P (SelP) (the two selenoproteins present in serum) were also determined within the same chromatographic run. The levels of selenium associated with SeAlb in three serum materials, namely BCR-637, Seronorm level 1 and Seronorm level 2, obtained using both methods were in a good agreement. Verification of the absence of free SeMet, which interferes with the SeAlb determination (down to the amino acid level), in such materials was addressed by analyzing the fraction of GPx, partially purified by AF-HPLC, using RP-HPLC (GPx only) and size exclusion-HPLC (SE-HPLC) coupled to CRC ICP-QMS. The latter methodology was also used for the investigation of the presence of selenium species other than the selenoproteins in the (AF-HPLC) SelP and SeAlb fractions; the same selenium peaks were detected in both control and BCR-637 serum with a difference in age of ca. 12 years. It is also for the first time that the concentrations of selenium associated with SeAlb, GPx and SelP species in such commercially available serums (only certified or having indicative levels of total selenium content) are reported. Such indicative values can be used for reference purposes in future validation of speciation methods for selenium in human serum and/or inter-laboratory comparisons.

  1. Validation of a high performance liquid chromatography method for quantitation of L-proline in 20 % tincture from Murraya paniculata L. Jack

    International Nuclear Information System (INIS)

    Varona Torres, Noel; Gutierrez Gaiten, Yamilet Irene; Casado Martin, Celia Magaly

    2014-01-01

    The search for analytical methods that may monitor the quality of drugs is an issue of great interest in the pharmaceutical field, even more if they are directed to studying chemical markers of medicinal plants, their extracts and phytomedicines. To validate a high-resolution liquid chromatography (HPLC) method for the quantitative determination of the L-proline amino acid as a marker substance in Murraya paniculata L. Jack tincture

  2. Further Validation of a Rapid Screening Semiquantitative Thin-Layer Chromatographic Method for Marketed Antimalarial Medicines for Adoption in Malawi

    Directory of Open Access Journals (Sweden)

    Dorcas Osei-Safo

    2018-01-01

    Full Text Available A recently developed semiquantitative thin-layer chromatographic (SQ-TLC assay has been employed in postmarketing surveillance of antimalarial medicines used in Malawi prior to HPLC assay. Both methods gave analogous results in a significant majority of the samples, with a good correlation (r = 0.9012 for the active pharmaceutical ingredients of the dosage forms assayed. Artemether-containing medicines had the highest percentage (92.67% of samples with comparable results for both assays. The lowest percentage (66.67% was observed in artesunate-containing medicines. The SQ-TLC method was validated for specificity, accuracy, precision, linearity, and stability according to the International Conference on Harmonisation guidelines, with the results falling within acceptable limits. For specificity, retention factor values of the test samples and reference standards were comparable, while accuracy and precision of 91.1 ± 5.7% were obtained for all samples. The method was linear in the range 1.0–2.0 µg/spot with a correlation coefficient of r = 0.9783. Stability tests also fell within acceptable limits. In this study, we present the validation of the SQ-TLC method and propose its adoption as a rapid screening tool for field estimation of the quality of antimalarial and other essential medicines in Malawi and other parts of the developing world prior to a more accurate HPLC assay.

  3. Development and validation of carbofuran and 3-hydroxycarbofuran analysis by high-pressure liquid chromatography with diode array detector (HPLC-DAD) for forensic Veterinary Medicine.

    Science.gov (United States)

    Gonçalves, Vagner; Hazarbassanov, Nicolle Queiroz; de Siqueira, Adriana; Florio, Jorge Camilo; Ciscato, Claudia Helena Pastor; Maiorka, Paulo Cesar; Fukushima, André Rinaldi; de Souza Spinosa, Helenice

    2017-10-15

    Agricultural pesticides used with the criminal intent to intoxicate domestic and wild animals are a serious concern in Veterinary Medicine. In order to identify the pesticide carbofuran and its metabolite 3- hydroxycarbofuran in animals suspected of exogenous intoxication a high pressure liquid chromatography with diode array detector (HPLC-DAD) method was developed and validated in stomach contents, liver, vitreous humor and blood. The method was evaluated using biological samples from seven different animal species. The following parameters of analytical validation were evaluated: linearity, precision, accuracy, selectivity, recovery and matrix effect. The method was linear at the range of 6.25-100μg/mL and the correlation coefficient (r 2 ) values were >0.9811 for all matrices. The precision and accuracy of the method was determined by coefficient of variation (CV) and the relative standard deviation error (RSE), and both were less than 15%. Recovery ranged from 74.29 to 100.1% for carbofuran and from 64.72 to 100.61% for 3-hydroxycarbofuran. There were no significant interfering peaks or matrix effects. This method was suitable for detecting 25 positive cases for carbofuran amongst a total of 64 animal samples suspected of poisoning brought to the Toxicology Diagnostic Laboratory, School of Veterinary Medicine and Animal Sciences, University of Sao Paulo. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Validation for The Quantification of Andrographolide Isolated from Andrographis paniculata Nees Plant Using HPLC

    OpenAIRE

    Yandi Syukri; Agung Endro Nugroho; Ronny Martien; Endang Lukitaningsih

    2015-01-01

    The aim of study was to develop quantitative analysis of isolated andrographolide from Andrographis paniculata and different solvent for prelimenary studies to preperation Self Nano Emulsifying Drug Delivery System (SNEDDS) using HPLC. The separation was acquired on Sunfire C18 column with an isocratic mixture of methanol and water at a ratio of 6:4, v/v as a mobile phase. The method to determine the content of isolated andrographolide showed an adequate precision, with a RSD smaller than 1%....

  5. Validation of a High-Performance Liquid Chromatography method for the determination of vitamin A, vitamin D3, vitamin E and benzyl alcohol in a veterinary oily injectable solution

    OpenAIRE

    Maria Neagu; Georgiana Soceanu; Ana Caterina Bucur

    2015-01-01

    A new simple, rapid, accurate and precise high – performance liquid chromatography (HPLC) method for determination of vitamin A, vitamin D3, vitamin E and benzyl alcohol in oily injectable solution was developed and validated. The method can be used for the detection and quantification of known and unknown impurities and degradants in the drug substance during routine analysis and also for stability studies in view of its capability to separate degradation products. The method was validate...

  6. Isolation and identification of arctiin and arctigenin in leaves of burdock (Arctium lappa L.) by polyamide column chromatography in combination with HPLC-ESI/MS.

    Science.gov (United States)

    Liu, Shiming; Chen, Kaoshan; Schliemann, Willibald; Strack, Dieter

    2005-01-01

    A simple method involving polyamide column chromatography in combination with HPLC-PAD and HPLC-ESI/MS for isolating and identifying two kinds of lignans, arctiin and arctigenin, in the leaves of burdock (Arctium lappa L.) has been established. After extraction of burdock leaves with 80% methanol, the aqueous phase of crude extracts was partitioned between water and chloroform and the aqueous phase was fractionated on a polyamide glass column. The fraction, eluting with 100% methanol, was concentrated and gave a white precipitate at 4 degrees C from which two main compounds were purified by semi-preparative HPLC. In comparison with the UV and ESI-MS spectra and the HPLC retention time of authentic standards, the compounds were determined to be arctiin and arctigenin. The extraction/separation technique was validated using an internal standard method.

  7. Development and Validation of RP-HPLC Method for Simultaneous Estimation of Ramipril, Aspirin and Atorvastatin in Pharmaceutical Preparations

    Directory of Open Access Journals (Sweden)

    Rajesh Sharma

    2012-01-01

    Full Text Available A simple, sensitive, accurate and rapid reverse phase high performance liquid chromatographic method is developed for the simultaneous estimation of ramipril, aspirin and atorvastatin in pharmaceutical preparations. Chromatography was performed on a 25cm×4.6 mm i.d, 5µm particle, C18 column with Mixture of (A acetonitrile methanol (65:35 and (B 10 mM sodium dihydrogen phosphate monohydrate (NaH2PO4.H2O buffer and mixture of A:B (60:40 v/v adjusted to pH 3.0 with o-phosphoric acid (5%v/v was used as a mobile phase at a flow rate of 1.5 ml min-1. UV detection was performed at 230 nm. Total run time was less then 12 min; retention time for Ramipril, aspirin and Atorvastatin were 3.620, 4.920 min and 11.710 min respectively. The method was validated for accuracy, precision, linearity, specificity and sensitivity in accordance with ICH guidelines. Validation revealed that the method is specific, rapid, accurate, precise, reliable, and reproducible. Calibration plots were linear over the concentration ranges 05-50 µg mL-1 for Ramipril, 05-100 µgmL-1 for aspirin and 02-20 µg mL-1 for atorvastatin. Limits of detection were 0.014, 0.10 and 0.0095 ng mL-1 limits of quantification were 0.043, 0.329 and 0.029 ng mL-1 for ramipril aspirin and atorvastatin respectively. The high recovery and low coefficients of variation confirm the suitability of the method for simultaneous analysis of the all three drugs in the dosage forms. The validated method was successfully used for quantitative analysis of marketed pharmaceutical preparations.

  8. Re-purification of labelled ferritin antigen with HPLC

    International Nuclear Information System (INIS)

    Zhang Haoyi; Jin Lichun

    2002-01-01

    Objective: To improve the quality of long-term stored labelled ferritin antigen with HPLC. Methods: The antigen was analyzed and purified with HPLC and again analyzed with RIA afterwards. Results: Ferritin antigen underwent significant polymerization after long-term (aggregation) storage. After re-purification with HPLC, its immuno-activity and labelled specific radioactivity were both significantly improved. Conclusion: Quality of stored ferritin RIA kit could be greatly improved after re-purification with HPLC

  9. Quantification of [18F]FDOPA and [18F]-3-OMFD in pig serum - a new TLC method in comparison with HPLC

    International Nuclear Information System (INIS)

    Pawelke, B.; Fuechtner, F.; Bergmann, R.; Brust, P.

    2002-01-01

    A novel TLC method for convenient quantification of [ 18 F]FDOPA and [ 18 F]-3-OMFD in routine operation was developed and the results assessed in comparison with an HPLC analysis. The two methods were found to correlate well. [ 18 F]fluoride which resisted determination on HPLC RP-18 columns was also quantified by TLC. (orig.)

  10. Determination of prodrug treosulfan and its biologically active monoepoxide in rat plasma, liver, lungs, kidneys, muscle, and brain by HPLC-ESI-MS/MS method.

    Science.gov (United States)

    Romański, Michał; Kasprzyk, Anna; Teżyk, Artur; Widerowska, Agnieszka; Żaba, Czesław; Główka, Franciszek

    2017-06-05

    A prodrug treosulfan (TREO) is currently investigated in clinical trials for conditioning prior to hematopoietic stem cell transplantation. Bioanalysis of TREO and its active derivatives, monoepoxide (S,S-EBDM) and diepoxide, in plasma and urine underlay the pharmacokinetic studies of these compounds but cannot explain an organ pharmacological action or toxicity. Recently, distribution of TREO and S,S-EBDM into brain, cerebrospinal fluid, and aqueous humor of the eye has been investigated in animal models and the obtained results presented clinical relevance. In this paper, a selective and rapid HPLC-ESI-MS/MS method was elaborated and validated for the studies of disposition of TREO and S,S-EBDM in rat plasma, liver, lungs, kidneys, muscle, and brain. The two analytes and codeine, internal standard (IS), were isolated from 50μL of plasma and 100μL of supernatants of the tissues homogenates using ultrafiltration Amicon vials. Chromatographic resolution was accomplished on C18 column with isocratic elution. The limits of quantitation of TREO and S,S-EBDM in the studied matrices ranged from 0.11 to 0.93μM. The HPLC-MS/MS method was adequately precise and accurate within and between runs. The IS-normalized matrix effect differed among the tissues and was the most pronounced in a liver homogenate supernatant (approximately 0.55 for TREO and 0.35 for S,S-EBDM). Stability of the analytes in experimental samples was also established. The validated method for the first time enabled determination of TREO and S,S-EBDM in the six life-important tissues in rats following administration of the prodrug. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. [Studies on HPLC-FPS of the saponins from Semen Ziziphi Spinosae].

    Science.gov (United States)

    Wu, He-zhen; Chen, Jing; Liu, Yan-wen

    2006-09-01

    To establish a method of HPLC-fingerprint spectrum (HPLC-FPS) for the active part in Semen Ziziphi Spinosae (SZS) in order to control the quality of SZS from different places. The gradient elution mode was applied in chromatographic separation, and data were analysed by" Similarity Evaluation software" to compare the HPLC-FPS of SZS from different places. The conditions for HPLC analysis of SZS were established and the FPS of samples from different habitats showed some differences. All components in the spectrum were separated well and the HPLC fingerprint method is repeatable. The method can be used in quality assessment of SZS.

  12. HPLC method development and validation for the estimation of axitinibe in rabbit plasma

    Directory of Open Access Journals (Sweden)

    Achanta Suneetha

    2017-10-01

    Full Text Available ABSTRACT A rapid, sensitive, and accurate high performance liquid chromatography for the determination of axitinibe (AN in rabbit plasma is developed using crizotinibe as an internal standard (IS. Axitinibe is a tyrosine kinase inhibitor, used in the treatment of advanced kidney cancer, which works by slowing or stopping the growth of cancer cells. The chromatographic separation was performed on a Waters 2695, Kromosil (150 mm × 4.6 mm, 5 µm column using a mobile phase containing buffer (pH 4.6 and acetonitrile in the ratio of 65:35 v/v with a flow rate of1 mL/min. The analyte and internal standard were extracted using liquid-liquid extraction with acetonitrile. The elution was detected by photo diode array detector at 320 nm.The total chromatographic runtime is 10.0 min with a retention time for axitinibe and IS of 5.685, and 3.606 min, respectively. The method was validated over a dynamic linear range of 0.002-0.2µg/mL for axitinibe with a correlation coefficient of r2 0.999.

  13. A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form.

    Science.gov (United States)

    Darsazan, Bahar; Shafaati, Alireza; Mortazavi, Seyed Alireza; Zarghi, Afshin

    2017-01-01

    A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C 18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 mL/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a retention time of 5.8 ± 0.01 min. No interferences were observed from its stress degradation products. The method was validated according to the international guidelines. Linear regression analysis of data for the calibration plot showed a linear relationship between peak area and concentration over the range of 0.5-16 μg/mL; the regression coefficient was 0.9999and the linear regression equation was y = 24844x-2941.3. The detection (LOD) and quantification (LOQ) limits were 0.12 and 0.35 μg/mL, respectively. The results proved the method was fast (analysis time less than 7 min), precise, reproducible, and accurate for analysis of ADV over a wide range of concentration. The proposed specific method was used for routine quantification of ADV in pharmaceutical bulk and a tablet dosage form.

  14. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations

    OpenAIRE

    Adi-Dako, Ofosua; Oppong Bekoe, Samuel; Ofori-Kwakye, Kwabena; Appiah, Enoch; Peprah, Paul

    2017-01-01

    An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections) pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18), 5??m, 4.6 ? 150?mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol?:?water?:?acetic acid (60?:?30?:?10, v/v/v) at ...

  15. Quantitative Determination of Catechin as Chemical Marker in Pediatric Polyherbal Syrup by HPLC/DAD.

    Science.gov (United States)

    Sheikh, Zeeshan A; Siddiqui, Zafar A; Naveed, Safila; Usmanghani, Khan

    2016-09-01

    Vivabon syrup is a balanced composition of dietary ingredients of phytopharmaceutical nature for maintaining the physique, vigor, vitality and balanced growth of children. The herbal ingredients of pediatric syrup are rich in bioflavonoid, proteins, vitamins, glycosides and trace elements. Vivabon is formulated with herbal drugs such as Phoenix sylvestris, Emblica officinalis, Withania somnifera, Centella asiatica, Amomum subulatum, Zingiber officinalis, Trigonella foenum-graecum, Centaurea behen and Piper longum Catechins are flavan-3-ols that are found widely in the medicinal herbs and are utilized for anti-inflammatory, cardio protective, hepato-protective, neural protection and other biological activities. In general, the dietary intake of flavonoids has been regarded traditionally as beneficial for body growth. Standardization of Vivabon syrup dosage form using HPLC/DAD has been developed for quantitative estimation of Catechin as a chemical marker. The method was validated as per ICH guidelines. Validation studies demonstrated that the developed HPLC method is quite distinct, reproducible as well as quick and fast. The relatively high recovery and low comparable standard deviation confirm the suitability of the developed method for the determination of Catechin in syrup. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Stability-indicating HPLC determination of pramipexole dihydrochloride in bulk drug and pharmaceutical dosage form

    OpenAIRE

    Panditrao, Vedavati M; Sarkate, Aniket P; Sangshetti, Jaiprakash N; Wakte, Pravin S; Shinde, Devanand B

    2011-01-01

    A novel stability-indicating high-performance liquid chromatographic assay method was developed and validated for quantitative determination of pramipexole dihydrochloride in bulk drugs and in pharmaceutical dosage form in the presence of degradation products. An isocratic, reversed phase HPLC method was developed to separate the drug from the degradation products, using an Ace5-C18 (250×4.6 mm, 5 µm) advance chromatography column, and 10 mmol L-1 ammonium acetate and acetonitrile (75:25 v/v)...

  17. Stability Indicating RP-HPLC Method for Simultaneous Determination of Aspirin and Clopidrogel in Dosage Form

    International Nuclear Information System (INIS)

    Mohd Gousuddin; Sengupta, P.; Tripathi, V.D.; Das, A.

    2016-01-01

    Stability-indicating High Performance Liquid Chromatographic (HPLC) method was developed for simultaneous Aspirin and Clopidogrel, A Phenomenex Gemini C-18, 5 μm column having 250 mm x 4.6 mm i.d. in isocratic mode, with mobile phase containing buffer solution 0.3 % orthophosphoric acid : acetonitrile (65:35, v/v). The flow rate was 1 ml/ min and effluents were monitored at 266 nm. For linearity seven points calibration curve were obtained in a concentration range from 0.030-0.120 mg/ ml for aspirin and 0.015-0.060 mg/ ml for clopidogrel with correlation coefficient 0.9999. In the present study stability indicating HPLC method for the combination was tested by degrading the drugs together under various stress conditions like acid hydrolysis, base hydrolysis, oxidation, thermal and photolytic stress which is recommended by ICH guideline. (author)

  18. Development and validation of reversed-phase high performance liquid chromatographic method for analysis of cephradine in human plasma samples

    International Nuclear Information System (INIS)

    Ahmad, M.; Usman, M.; Madni, A.; Akhtar, N.; Khalid, N.; Asghar, W.

    2010-01-01

    An HPLC method with high precision, accuracy and selectivity was developed and validated for the assessment of cephradine in human plasma samples. The extraction procedure was simple and accurate with single step followed by direct injection of sample into HPLC system. The extracted cephradine in spiked human plasma was separated and quantitated using reversed phase C/sub 18/ column and UV detection wavelength of 254 nm. The optimized mobile phase of new composition of 0.05 M potassium dihydrogen phosphate (pH 3.4)-acetonitrile (88: 12) was pumped at an optimum flow rate of 1 mL.min/sup 1/. The method resulted linearity in the concentration range 0.15- 20 micro g mL/sup -1/. The limit of detection (LOD) and limit of quantification (LOQ) were 0.05 and 0.150 Microg.mL/sup -1/, respectively. The accuracy of method was 98.68 %. This method can 1>e applied for bioequivalence studies and therapeutic drug monitoring as well as for the routine analysis of cephradine. (author)

  19. Simultaneous Estimation of Gemcitabine Hydrochloride and Capecitabine Hydrochloride in Combined Tablet Dosage Form by RP-HPLC Method

    Directory of Open Access Journals (Sweden)

    V. Rajesh

    2011-01-01

    Full Text Available A new reverse phase high performance liquid chromatography (RP-HPLC method has been developed for the simultaneous estimation of gemcitabine hydrochloride and capecitabine hydrochloride in combined tablet dosage form. An inertsil ODS-3 C-18 column having dimensions of 250×4.6 mm and particle size of 5 µm, with mobile phase containing a mixture of acetonitrile : water : triethyelamine in the ratio of (70 : 28 : 2v/v was used. The pH of mobile phase was adjusted to 4.0 with ortho-phosphoric acid. The flow rate was 1 mL/min and the column effluents were monitored at 260 nm. The retention time for gemcitabine hydrochloride and capecitabine hydrochloride was found to be 2.76 and 2.3 min respectively. The proposed method was validated in terms of linearity, accuracy, precision, limit of detection, limit of quantitation and robustness. The method was found to be linear in the range of 10-50 µg/mL and 4-24 µg/mL for gemcitabine hydrochloride and capecitabine hydrochloride, with regression coefficient r = 0.999 and r = 0.999, respectively.

  20. Dual Wavelength RP-HPLC Method for Simultaneous Determination of Two Antispasmodic Drugs: An Application in Pharmaceutical and Human Serum

    Directory of Open Access Journals (Sweden)

    Najmul Hasan

    2013-01-01

    Full Text Available A reverse phase stability indicating HPLC method for simultaneous determination of two antispasmodic drugs in pharmaceutical parenteral dosage forms (injectable and in serum has been developed and validated. Mobile phase ingredients consist of Acetonitrile : buffer : sulfuric acid 0.1 M (50 : 50 : 0.3 v/v/v, at flow rate 1.0 mL/min using a Hibar μBondapak ODS C18 column monitored at dual wavelength of 266 nm and 205 nm for phloroglucinol and trimethylphloroglucinol, respectively. The drugs were subjected to stress conditions of hydrolysis (oxidation, base, acid, and thermal degradation. Oxidation degraded the molecule drastically while there was not so much significant effect of other stress conditions. The calibration curve was linear with a correlation coefficient of 0.9999 and 0.9992 for PG and TMP, respectively. The drug recoveries fall in the range of 98.56% and 101.24% with 10 pg/mL and 33 pg/mL limit of detection and limit of quantification for both phloroglucinol and trimethylphloroglucinol. The method was validated in accordance with ICH guidelines and was applied successfully to quantify the amount of trimethylphloroglucinol and phloroglucinol in bulk, injectable form and physiological fluid. Forced degradation studies proved the stability indicating abilities of the method.

  1. Stability-Indicating RP-HPLC Methods for the Determination of Fluorometholone in Its Mixtures with Sodium Cromoglycate and Tetrahydrozoline Hydrochloride.

    Science.gov (United States)

    El-Bagary, Ramzia I; Fouad, Marwa A; El-Shal, Manal A; Tolba, Enas H

    2016-07-01

    Two stability-indicating reversed-phase liquid chromatographic methods were developed and validated for the determination of fluorometholone (FLU) in its mixtures with sodium cromoglycate (SCG) and tetrahydrozoline hydrochloride (THZ). The first HPLC method (Method 1) was based on isocratic elution of FLU and SCG along with their alkaline degradation products on a reversed phase C18 column (250 × 4.6 mm id)-ACE Generix 5, using a mobile phase consisting of methanol-water (70 : 30, v/v), pH adjusted to 2.5 using orthophosphoric acid at a flow rate of 1.2 mL min(-1) Quantitation was achieved with UV detection at 240 nm. The second HPLC method (Method 2) was based on isocratic elution of FLU, its alkaline degradation product and THZ on a reversed phase C8 column (250 × 4.6 mm)-ACE Generix 5, using a mobile phase consisting of acetonitrile-50 mM potassium dihydrogen orthophosphate (40 : 60, v/v) at a flow rate of 2 mL min(-1) Quantitation was achieved by applying dual-wavelength detection, where FLU and its alkaline degradation product were detected at 240 nm and THZ was detected at 215 nm at ambient temperatures. Linearity, accuracy and precision were found to be acceptable over the concentration range of 5-50 and 10-500 μg mL(-1) for FLU and SCG (Method 1) and over the concentration range of 5-80 and 5-60 μg mL(-1) for FLU and THZ (Method 2), respectively. Besides, the FLU alkaline degradation product was verified using IR, NMR and LC-MS spectroscopy. The two proposed methods could be successfully applied for the routine analysis of the studied drugs either in their pure bulk powders or in their pharmaceutical preparations without any preliminary separation step. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Development of HPLC and UV spectrophotometric methods for the determination of ascorbic acid using hydroxypropyl-β-cyclodextrin and triethanolamine as photostabilizing agents

    International Nuclear Information System (INIS)

    Garnero, Claudia; Longhi, Marcela

    2010-01-01

    In this study, the effect of complex formation with triethanolamine (TEA) alone and in combination with hydroxypropyl-β-cyclodextrin (HP-β-CD) on the photostability of ascorbic acid was evaluated for exposure to artificial and diffuse daylight. The first-order rate constants for the photodegradation reactions were determined. The data obtained showed that these complexes strongly reduced the photodegradation process with an 11- and 35-fold increase in the photostability of ascorbic acid, depending of the ligand concentration and the irradiation source. The multicomponent complex gave a significantly better stabilization for exposure to light than TEA alone. Due to the fact that the complexation extended the exposure of ascorbic acid to light (without molecular changes), UV spectrophotometric and reversed phase high performance liquid chromatographic (HPLC) methods were developed for the quantitative determination of the vitamin in pure form and in pharmaceutical preparations. These methods were statistically validated, all the validation parameters were found to be within the acceptance range. These results demonstrate that the proposed methods are suitable for the quality control of ascorbic acid, providing simple, rapid, precise, accurate and convenient approaches for routine analysis of bulk drug and pharmaceutical formulations.

  3. Development of an HPLC Method with an ODS Column to Determine Low Levels of Aspartame Diastereomers in Aspartame.

    Science.gov (United States)

    Ohtsuki, Takashi; Nakamura, Ryoichiro; Kubo, Satoru; Otabe, Akira; Oobayashi, Yoko; Suzuki, Shoko; Yoshida, Mika; Yoshida, Mitsuya; Tatebe, Chiye; Sato, Kyoko; Akiyama, Hiroshi

    2016-01-01

    α-L-Aspartyl-D-phenylalanine methyl ester (L, D-APM) and α-D-aspartyl-L-phenylalanine methyl ester (D, L-APM) are diastereomers of aspartame (N-L-α-Aspartyl-L-phenylalanine-1-methyl ester, L, L-APM). The Joint FAO/WHO Expert Committee on Food Additives has set 0.04 wt% as the maximum permitted level of the sum of L, D-APM and D, L-APM in commercially available L, L-APM. In this study, we developed and validated a simple high-performance liquid chromatography (HPLC) method using an ODS column to determine L, D-APM and D, L-APM in L, L-APM. The limits of detection and quantification, respectively, of L, D-APM and D, L-APM were found to be 0.0012 wt% and 0.004 wt%. This method gave excellent accuracy, repeatability, and reproducibility in a recovery test performed on five different days. Moreover, the method was successfully applied to the determination of these diastereomers in commercial L, L-APM samples. Thus, the developed method is a simple, useful, and practical tool for determining L, D-APM and D, L-APM levels in L, L-APM.

  4. Development of an HPLC Method with an ODS Column to Determine Low Levels of Aspartame Diastereomers in Aspartame.

    Directory of Open Access Journals (Sweden)

    Takashi Ohtsuki

    Full Text Available α-L-Aspartyl-D-phenylalanine methyl ester (L, D-APM and α-D-aspartyl-L-phenylalanine methyl ester (D, L-APM are diastereomers of aspartame (N-L-α-Aspartyl-L-phenylalanine-1-methyl ester, L, L-APM. The Joint FAO/WHO Expert Committee on Food Additives has set 0.04 wt% as the maximum permitted level of the sum of L, D-APM and D, L-APM in commercially available L, L-APM. In this study, we developed and validated a simple high-performance liquid chromatography (HPLC method using an ODS column to determine L, D-APM and D, L-APM in L, L-APM. The limits of detection and quantification, respectively, of L, D-APM and D, L-APM were found to be 0.0012 wt% and 0.004 wt%. This method gave excellent accuracy, repeatability, and reproducibility in a recovery test performed on five different days. Moreover, the method was successfully applied to the determination of these diastereomers in commercial L, L-APM samples. Thus, the developed method is a simple, useful, and practical tool for determining L, D-APM and D, L-APM levels in L, L-APM.

  5. Simultaneous determination of glucose, fructose, sucrose and sorbitol in the leaf and fruit peel of different apple cultivars by the HPLC-RI optimized method.

    Science.gov (United States)

    Filip, Miuţa; Vlassa, Mihaela; Coman, Virginia; Halmagyi, Adela

    2016-05-15

    A high performance liquid chromatography method with refractive index detection (HPLC-RI), for simultaneous determination of glucose, fructose, sucrose and sorbitol in leaf and/or apple peel samples from nine apple (Malus domestica Borkh.) cultivars and rootstocks, originating from a germplasm collection, has been developed and validated. Box-Behnken design of response surface methodology was applied for the method optimization. The Carbosep Coregel 87H3 column was used under the optimum conditions predicted: mobile phase of H2SO4 0.005 mol L(-1) solution, flow rate of 0.3 mL min(-1) and column temperature of 35°C. The method was validated for linearity (R(2)>0.99), limits of detection (2.67-4.83 μg mL(-1)) and quantification (8.9-16.1 μg mL(-1)), precision (%RSD<5.05) and recovery (93.94-103.06%) and satisfactory results obtained. The sugars content varied across micropropagated plants in vitro, plants regenerated after cryostorage, growing trees in vivo, and fruit peel. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. A comparative study for PSP toxins quantification by using MBA and HPLC official methods in shellfish.

    Science.gov (United States)

    Ben-Gigirey, B; Rodríguez-Velasco, M L; Otero, A; Vieites, J M; Cabado, A G

    2012-10-01

    Commission Regulation (EC) N° 2074/2005 recognises the biological method as the reference method for Paralytic Shellfish Poisoning (PSP) toxins detection in molluscs. It was amended by Commission Regulation (EC) N° 1664/2006 that accepted the so-called Lawrence method as an alternative to the reference method. The goal of this study was to compare AOAC Official Methods of Analysis 959.08 (Biological method) and 2005.06 (Prechromatographic Oxidation and Liquid Chromatography with fluorescence detection) in samples with different toxin profiles. The influence of extraction solvent in the total samples toxicity was also evaluated. A total of 40 samples including mussels, clams, scallops, razor-clams, cockles, oysters and barnacles were analysed by both official methods. Samples were selected with Alexandrium and Gymnodinium toxic profiles, from different origin and including several presentations: fresh, frozen, canned and boiled. Acetic and hydrochloric acid extractions were performed in all samples and the extracts were simultaneously analysed by both methods. Most samples were naturally contaminated and two samples were spiked. Comparison of both official methods, mouse bioassay (MBA) with HCl extraction and Liquid Chromatography with fluorescence detection (HPLC-FLD) with acetic acid extraction, led to an 85% of consistent results regarding compliance with legal limit, including samples below and above it. The linear correlation coefficient was r² = 0.69 and the paired t test (two tails, α = 0.05) indicated that there were not significant differences among both sets of data. Nevertheless, toxicity differences were found in several samples. In 15 out of 18 shellfish with a Gymnodinium toxic profile, higher toxicity levels were obtained by MBA. This fact was more evident in 7 samples, partially related to the lack of standards and the impossibility of analysing dc-NEO, C1, 2 and GTX6 at the beginning of the study. However, other factors concerning the extraction

  7. Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method

    OpenAIRE

    Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, MahmoudReza; Karami-Osboo, Rouhollah

    2013-01-01

    Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 ?L of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase con...

  8. Chemical fingerprinting and quantitative analysis of a Panax notoginseng preparation using HPLC-UV and HPLC-MS

    Directory of Open Access Journals (Sweden)

    Shao Qing

    2011-02-01

    Full Text Available Abstract Background Xuesaitong (XST injection, consisting of total saponins from Panax notoginseng, was widely used for the treatment of cardio- and cerebro-vascular diseases in China. This study develops a simple and global quality evaluation method for the quality control of XST. Methods High performance liquid chromatography-ultraviolet detection (HPLC-UV was used to identify and quantify the chromatographic fingerprints of the XST injection. Characteristic common peaks were identified using HPLC with photo diode array detection/electrospray ionization tandem mass spectrometry (HPLC-PDA/ESI-MSn. Results Representative fingerprints from ten batches of samples showed 27 'common saponins' all of which were identified and quantified using ten reference saponins. Conclusion Chemical fingerprinting and quantitative analysis identified most of the common saponins for the quality control of P. notoginseng products such as the XST injection.

  9. HPLC fingerprint analysis combined with chemometrics for pattern recognition of ginger.

    Science.gov (United States)

    Feng, Xu; Kong, Weijun; Wei, Jianhe; Ou-Yang, Zhen; Yang, Meihua

    2014-03-01

    Ginger, the fresh rhizome of Zingiber officinale Rosc. (Zingiberaceae), has been used worldwide; however, for a long time, there has been no standard approbated internationally for its quality control. To establish an efficacious and combinational method and pattern recognition technique for quality control of ginger. A simple, accurate and reliable method based on high-performance liquid chromatography with photodiode array (HPLC-PDA) detection was developed for establishing the chemical fingerprints of 10 batches of ginger from different markets in China. The method was validated in terms of precision, reproducibility and stability; and the relative standard deviations were all less than 1.57%. On the basis of this method, the fingerprints of 10 batches of ginger samples were obtained, which showed 16 common peaks. Coupled with similarity evaluation software, the similarities between each fingerprint of the sample and the simulative mean chromatogram were in the range of 0.998-1.000. Then, the chemometric techniques, including similarity analysis, hierarchical clustering analysis and principal component analysis were applied to classify the ginger samples. Consistent results were obtained to show that ginger samples could be successfully classified into two groups. This study revealed that HPLC-PDA method was simple, sensitive and reliable for fingerprint analysis, and moreover, for pattern recognition and quality control of ginger.

  10. Development and Validation of Improved Method for Fingerprint ...

    African Journals Online (AJOL)

    Methods: The optimum high performance capillary electrophoresis (HPCE) ... organic solvent, and were analyzed using HPLC ... quantified to 200 ml with water and centrifuged at ..... for the analysis of flavonoids in selected Thai plants by.

  11. Development and validation of an HPLC method to quantify camptothecin in polymeric nanocapsule suspensions.

    Science.gov (United States)

    Granada, Andréa; Murakami, Fabio S; Sartori, Tatiane; Lemos-Senna, Elenara; Silva, Marcos A S

    2008-01-01

    A simple, rapid, and sensitive reversed-phase column high-performance liquid chromatographic method was developed and validated to quantify camptothecin (CPT) in polymeric nanocapsule suspensions. The chromatographic separation was performed on a Supelcosil LC-18 column (15 cm x 4.6 mm id, 5 microm) using a mobile phase consisting of methanol-10 mM KH2PO4 (60 + 40, v/v; pH 2.8) at a flow rate of 1.0 mL/min and ultraviolet detection at 254 nm. The calibration graph was linear from 0.5 to 3.0 microg/mL with a correlation coefficient of 0.9979, and the limit of quantitation was 0.35 microg/mL. The assay recovery ranged from 97.3 to 105.0%. The intraday and interday relative standard deviation values were entrapment efficiency and drug content in polymeric nanocapsule suspensions during the early stage of formulation development.

  12. Multiresidue screening method for detection of benzimidazoles and their metabolites in liver and muscle by high-performance liquid chromatography: method development and validation according to Commission Decision 2002/657/EC

    Directory of Open Access Journals (Sweden)

    Marilena Gili

    2014-02-01

    Full Text Available The use of veterinary drugs may cause the presence of residues in food of animal origin if appropriate withdrawal periods are not respected. A high-performance liquid chromatography (HPLC method has been developed for the simultaneous detection of 11 benzimidazole residues, including metabolites – albendazole, albendazole sulphoxide, albendazole sulphone, fenbendazole, fenbendazole sulphoxide (oxfendazole, fenbendazole sulphone, flubendazole, mebendazole, oxibendazole, thiabendazole, 5-hydroxythiabendazole – in bovine, ovine, equine, swine, rabbit and poultry liver and in bovine, swine and fish muscle. After extraction with a dicloromethane/acetonitrile solution (35/65 v/v containing 5% ammonium hydroxide, the solvent was evaporated to dryness, the residue was dissolved in HCl 0.1 M, defatted with hexane, purified on a strong cation exchange solid-phase extraction cartridge and analysed in HPLC with diode array and fluorescence detectors. The method was validated as screening qualitative method evaluating, according to Commission Decision 2002/657/EC criteria, specificity, CCb and b error at cut off level of 25 mg/kg and ruggedness.

  13. Development and validation of stability indicating studies of ...

    African Journals Online (AJOL)

    Development and validation of stability indicating studies of paliperidone ... A simple and sensitive stability indicating HPLC method is developed for the ... The developed method was proved adequate for quantitative determination of ... Browse By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  14. "INTRODUCING A FULL VALIDATED ANALYTICAL PROCEDURE AS AN OFFICIAL COMPENDIAL METHOD FOR FENTANYL TRANSDERMAL PATCHES"

    Directory of Open Access Journals (Sweden)

    Amir Mehdizadeh

    2005-04-01

    Full Text Available A simple, sensitive and specific HPLC method and also a simple and fast extraction procedure were developed for quantitative analysis of fentanyl transdermal patches. Chloroform, methanol and ethanol were used as extracting solvents with recovery percent of 92.1, 94.3 and 99.4% respectively. Fentanyl was extracted with ethanol and the eluted fentanyl through the C18 column was monitored by UV detection at 230 nm. The linearity was at the range of 0.5-10 µg/mL with correlation coefficient (r2 of 0.9992. Both intra and inter-day accuracy and precision were within acceptable limits. The detection limit (DL and quantitation limit (QL were 0.15 and 0.5 µg/mL, respectively. Other validation characteristics such as selectivity, robustness and ruggedness were evaluated. Following method validation, a system suitability test (SST including capacity factor (k´, plate number (N, tailing factor (T, and RSD was defined for routine test.

  15. Simultaneous HPLC method for determination of sodium trimethoprim phenylpropanol disulphonate and sodium sulfaquinoxaline in veterinary drugs

    Directory of Open Access Journals (Sweden)

    Puangkaew Lakkanatinaporn

    2004-11-01

    Full Text Available A simple HPLC method has been developed for the separation and determination of sodium trimethoprim phenylpropanol disulphonate and sodium sulfaquinoxaline in veterinary preparations. Both drugs were separated well on a Kromasil C18 column (5 µm, 150 × 4.6 mm using a mixture of acetonitrile and 0.5% triethylamine in 1% acetic acid, pH 3 (18:82, v/v as the mobile phase at the flow rate of 1.5 ml/ min. The presence of both substances was monitored by UV absorption detection at 271 nm. The retention times of sodium trimethoprim phenylpropanol disulphonate and sodium sulfaquinoxaline were 3.2 and 16.0 min, respectively. The performance of the developed method was tested. Linear responses of both drugs were achieved between 48-145% of labeled amount over the concentration ranges of 35-101 µg/ml and 102-306 µg/ ml for sodium trimethoprim phenylpropanol disulphonate and sodium sulfaquinoxaline with correlation coefficients (R2 of 0.9980 and 0.9998, respectively. Accuracy expressed in term of recoveries were 101.4± 1.21% (n=6 for sodium trimethoprim phenylpropanol disulphonate and 99.7±0.92% (n=6 for sodium sulfaquinoxaline. Precision of the method in terms of the relative standard deviation is not more than 2% in all cases. These figures of merit indicated the validity of the developed method.

  16. Development and Validation of a Reversed-Phase Liquid Chromatography Method for the Simultaneous Determination of Indole-3-Acetic Acid, Indole-3-Pyruvic Acid, and Abscisic Acid in Barley (Hordeum vulgare L.).

    Science.gov (United States)

    Nakurte, Ilva; Keisa, Anete; Rostoks, Nils

    2012-01-01

    A simple, sensitive, precise, and specific reverse HPLC method was developed and validated for the determination of plant hormones in barley (Hordeum vulgare L.). The method includes extraction in aqueous organic solvent followed by solid-phase extraction, sample evaporation, and reversed-phase HPLC analysis in a general purpose UV-visible (abscisic acid (ABA)) and fluorescence detection (indole-3-acetic acid (IAA) and indole-3-pyruvic acid (IPA)), high-performance liquid chromatography system. The separation was carried out on Zorbax Eclipse XDB C8 column (150  ×  4.6  mm I.D) with a mobile phase composed of methanol and 1% acetic acid (60 : 40 v/v) in isocratic mode at a flow rate of 1 ml min(-1). The detection was monitored at 270 nm (ABA) and at 282 nm (Ex) and 360 nm (Em) (IAA, IPA). The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantification, and robustness. The determined validation parameters are in the commonly acceptable ranges for that kind of analysis.

  17. Bioavailability of wilforlide A in mice and its concentration determination using an HPLC-APCI-MS/MS method.

    Science.gov (United States)

    Wang, Zhijun; Yeung, Steven; Chen, Shang; Moatazedi, Yasmin; Chow, Moses S S

    2018-07-15

    Wilforlide A (WA), an active compound in Tripterygium wilfordii Hook F (TW) which is a traditional Chinese medicine for treatment of autoimmune diseases, is a quality control marker for TW product. At present, the bioavailability/pharmacokinetics of WA is not known. Such information is not only essential to evaluate the relevance of WA as a quality control maker, but also important for future clinical efficacy studies. Therefore, a high-performance liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometric method (HPLC-APCI-MS/MS) was developed and applied to a bioavailability/pharmacokinetic study of WA. WA and celastrol (the internal standard, IS) were extracted by a liquid-liquid extraction method using methyl tert-butyl ether. Multiple reaction monitoring (MRM) scanning in positive ionization mode was used to monitor the transition of m/z 455.1 to 191.3 for WA and 451.3 to 201.2 for IS. This method was validated and applied to a pharmacokinetic study of WA in mice following intravenous administration (IV, 1.2 mg/kg), intraperitoneal injection (IP, 6 mg/kg) and oral administration (PO, 30 mg/kg). The lower limit of quantification (LLOQ) for WA was 10 ng/ml. The intra- and inter-day precision was found to be within 15.4% while the accuracy within 94.1-115.7% for all the quality control and LLOQ samples. The samples were stable under all the usual storage and experimental conditions. The terminal elimination half-lives were 14.7, 9.1 and 22.7 min following IV, IP and PO dosing, while the absolute bioavailability for IP and PO WA were 9.39% and 0.58% respectively. These results indicated that the HPLC-APCI-MS/MS assay was suitable for the pharmacokinetic study of WA. WA was found poorly absorbed when given orally and therefore it may not be a relevant marker for the oral TW products in the market. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Development and validation of stability indicating method for the quantitative determination of venlafaxine hydrochloride in extended release formulation using high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Jaspreet Kaur

    2010-01-01

    Full Text Available Objective : Venlafaxine,hydrochloride is a structurally novel phenethyl bicyclic antidepressant, and is usually categorized as a serotonin-norepinephrine reuptake inhibitor (SNRI but it has been referred to as a serotonin-norepinephrine-dopamine reuptake inhibitor. It inhibits the reuptake of dopamine. Venlafaxine HCL is widely prescribed in the form of sustained release formulations. In the current article we are reporting the development and validation of a fast and simple stability indicating, isocratic high performance liquid chromatographic (HPLC method for the determination of venlafaxine hydrochloride in sustained release formulations. Materials and Methods : The quantitative determination of venlafaxine hydrochloride was performed on a Kromasil C18 analytical column (250 x 4.6 mm i.d., 5 μm particle size with 0.01 M phosphate buffer (pH 4.5: methanol (40: 60 as a mobile phase, at a flow rate of 1.0 ml/min. For HPLC methods, UV detection was made at 225 nm. Results : During method validation, parameters such as precision, linearity, accuracy, stability, limit of quantification and detection and specificity were evaluated, which remained within acceptable limits. Conclusions : The method has been successfully applied for the quantification and dissolution profiling of Venlafaxine HCL in sustained release formulation. The method presents a simple and reliable solution for the routine quantitative analysis of Venlafaxine HCL.

  19. Determination of organic acids evolution during apple cider fermentation using an improved HPLC analysis method

    NARCIS (Netherlands)

    Zhang, H.; Zhou, F.; Ji, B.; Nout, M.J.R.; Fang, Q.; Zhang, Z.

    2008-01-01

    An efficient method for analyzing ten organic acids in food, namely citric, pyruvic, malic, lactic, succinic, formic, acetic, adipic, propionic and butyric acids, using HPLC was developed. Boric acid was added into the mobile phase to separate lactic and succinic acids, and a post-column buffer

  20. QuEChERS-HPLC-DAD method for sulphonamides in chicken breast

    Directory of Open Access Journals (Sweden)

    Simone Caetani Machado

    2013-03-01

    Full Text Available The development of a QuEChERS-HPLC-DAD method using a Lichrospher 60 RP-Select B column (250 x 4.6 mm x 5 µm at 40ºC, mobile phase constituted by phosphate buffer:acetonitrile (75:25, v/v at a initial flow rate of 0.5 mL min-1, increased by 1.2 mL min-1 and at 265 nm is presented for simultaneous determination of sulphadiazine, sulphametoxipiridazine and sulphamethoxazole in chicken breast samples. QuEchERS is inexpensive, fast and easy, and the extraction of the analytes of the matrix was successfully employed. In addition, the method presented linearity, in the range of 25, 50, 100, 150, 175, and 200 µg kg-1, precision, selectivity and sensitivity. The intraday precision (RSD % for QuEChERS method was between 3.6-10.8 (SDZ, 6.9-14.1 (SPZ and 1.9-10.9 (SMX and interday precision (RSD% was between 1.5-9.7, 1.7-4.1 and 2.1-10.2, respectively. Results of accuracy (bias were in the range of -8.6 to +11.9 %. Therefore, the validated method is clearly useful for the practical residue monitoring of the drugs evaluated in chicken samples, as all the values were within the acceptable criteria used for food safety. Of 6 samples analyzed, none of them showed contamination of the sulphonamides studied at detectable levels.O desenvolvimento de um método QuEChERS-HPLC-DAD usando uma coluna Lichrospher RP-60 Select B (250 x 4,6 mm x 5 µm a 40 ºC, fase móvel constituída por tampão de fosfato: acetonitrila (75:25, v/v a uma vazão inicial de 0,5 mL min-1, aumentando 1,2 mL min-1 e a 265 nm é apresentado para a determinação simultânea de sulfadiazina, sulfametoxipiridazina e sulfametoxazol em amostras de peito de frango. O QuEChERS é barato, rápido e fácil, e a extração dos analitos da matriz foi empregada com sucesso. Além disso, o método apresentou linearidade, na faixa de 25, 50, 100, 150, 175 e 200 µg kg-1, precisão, seletividade e sensibilidade. A precisão intradia (RSD % para o método QuEChERS foi entre 3,6-10,8 (SDZ, 6,9-14,1 (SPZ

  1. RP-HPLC-DAD method for the determination of phenylepherine, paracetamol, caffeine and chlorpheniramine in bulk and marketed formulation

    Directory of Open Access Journals (Sweden)

    A.P. Dewani

    2014-11-01

    Full Text Available A simple, specific and accurate isocratic RP-HPLC-DAD method was developed for the simultaneous determination of phenylephrine, paracetamol, caffeine and chlorpheniramine in bulk and tablet dosage form. The four contents are present in variable concentrations and have variable chromatographic behavior making the process of analysis very difficult. For present studies a reversed-phase C-18 column (150 mm × 4.5 mm i.d., particle size 5 μm with mobile phase consisting of acetonitrile, methanol and 10 Mm phosphate buffer 16:22:62 (v/v (pH of buffer 2.5 ± 0.02, adjusted with ortho phosphoric acid was used. The flow rate was 1.0 ml/min and eluents were monitored at 280 nm. The mean retention times of phenylephrine, paracetamol, caffeine and chlorpheniramine were found to be 1.8, 3.1, 5.2 and 10.9 min, respectively. The method was validated in terms of linearity, range, specificity, accuracy, precision and robustness. The proposed method was successfully applied to the estimation of phenylephrine, paracetamol, caffeine and chlorpheniramine in combined tablet dosage form.

  2. Development and Validation of a RP-HPLC Method for the ...

    African Journals Online (AJOL)

    Erah

    Methods: Reverse phase (RP) chromatographic separation and estimation was achieved ... Recently, the use of natural products in ... one of the major consequences of herb-drug ... assurance and routine analysis of the blend. .... The robustness of the method was evaluated .... compliance with regulatory requirements) of.

  3. Validated high-performance liquid chromatographic method for the standardisation of Ptychopetalum olacoides Benth., Olacaceae, commercial extracts

    Directory of Open Access Journals (Sweden)

    Renata Colombo

    2010-10-01

    Full Text Available Ptychopetalum olacoides Benth., Olacaceae, popularly known as marapuama or muirapuama or miriantã, is a species native to the Amazonian region of Brazil. Extracts of the bark of the plant have been used traditionally for its stimulating and aphrodisiac properties and currently commercialised by the herbal industry as constituents in a wide range of phytomedicines. Fractionation by open column chromatography followed by preparative HPLC-UV/PAD of the stem bark and of three commercial extracts of P. olacoides allowed the isolation of three components that were common to all extracts analysed, and these were identified by NMR to be vanillic acid, protocatechuic acid and theobromine. Vanillic acid, which has been proposed as a phytochemical marker for P. olacoides, was employed as an external standard in the development and validation of a rapid qualitative and quantitative HPLC assay for the analyte. The recoveries values of the developed method were 99.02% and the LOD and LOQ values were 0.033 and 0.11 mg.L-1, respectively. The described method may be applied to the standardisation of herbs, extracts or phytomedicines commercialised as marapuama.

  4. Development and Validation of LC Method for the Determination of Famciclovir in Pharmaceutical Formulation Using an Experimental Design

    Directory of Open Access Journals (Sweden)

    Srinivas Vishnumulaka

    2008-01-01

    Full Text Available A rapid and sensitive RP-HPLC method with UV detection (242 nm for routine analysis of famciclovir in pharmaceutical formulations was developed. Chromatography was performed with mobile phase containing a mixture of methanol and phosphate buffer (50:50, v/v with flow rate 1.0 mL min−1. Quantitation was accomplished with internal standard method. The procedure was validated for linearity (correlation coefficient =0.9999, accuracy, robustness and intermediate precision. Experimental design was used for validation of robustness and intermediate precision. To test robustness, three factors were considered; percentage v/v of methanol in mobile phase, flow rate and pH; flow rate, the percentage of organic modifier and pH have considerable important effect on the response. For intermediate precision measure the variables considered were: analyst, equipment and number of days. The RSD value (0.86%, n=24 indicated an acceptable precision of the analytical method. The proposed method was simple, sensitive, precise, accurate and quick and useful for routine quality control.

  5. Validasi Metode HPLC untuk Penetapan Aspirin dan Asam Salisilat dalam Plasma Kelinci (Lepus curpaeums secara Simultan

    Directory of Open Access Journals (Sweden)

    Agus Siswanto

    2017-02-01

    Full Text Available Aspirin is a nonsteroidal anti-inflammatory drug which also has the effect of antiplatelet for stroke prevention. Aspirin inside human body is very easy to break down into salicylic acid as the main metabolite. The aim of this study is to develop and validate the method for determinating aspirin and salicylic acid concentration in plasma by HPLC. Method validation including system suitability test, linearity test, determination of LOD and LOQ, recovery, accuracy and precision. Concentration of analytes in blood is measured by HPLC using benzoic acid as internal standard, with condition Purospher column Endcapped Star RP-18 (250 x 4.6 mm id, 5 m, acetonitrile : buffer phosphate 20 mM pH 2.5 (30:70 v/v as mobile phase, injection volume 20 mL, flow rate 1.5 mL/minute, and UV-Vis detector λ 230 nm. The results showed that the proposed method meets the requirements of system suitability and good linearity (r > 0,990 with LOQ (aspirin = 0.024 mg/mL, salicylic acid = 0.336 mg/mL and LOD (aspirin = 0.007 mg/mL, salicylic acid = 0.101 mg/mL. The method of analysis provides recovery of 85-115 %, accuracy and precision in accordance with the requirements for bioanalytical with CV < 5 %. Therefore, the proposed method is applicable to determine of aspirin and salicylic acid concentration in plasma.

  6. Quantification of urea in serum by isotope dilution HPLC/MS

    International Nuclear Information System (INIS)

    Lee, Hwa Shim; Park, Sang Ryoul

    2005-01-01

    Urea in blood has been measured as an effective marker for diagnosis of renal function. Urea which is the end-product of nitrogen containing metabolites such as proteins is filtered through glomeruli of kidneys and then excreted as urine. If the renal function is deteriorated, the urea concentration in blood will be increased, from which the healthiness of renal function is judged. In order to improve the confidence of diagnosis results, the results must keep traceability chain to certified reference materials, which was certified by primary reference method. In this study, we proposed Isotope Dilution-Liquid Chromatography/Mass Spectrometry (ID-LC/MS) as a candidate primary method, in which 15 N 2 -urea is used as an internal reference material. The developed method is highly accurate in principle and is convenient as it does not require cumbersome derivatization 0.1 mmol/L ammonium chloride was selected as a mobile phase for HPLC because it provide low interference in MS analysis of relatively low molecular weighted urea. HPLC and MS were connected with an ElectroSpry Ionization(ESI) interface of positive mode, which provided high sensitivity and reproducibility. The developed method was validated with internationally recognized reference materials, and we have obtained satisfactory results in an international ring trial. The expanded uncertainty calculated according to ISO guide was 1.8% at 95% confidence interval. The developed method is being used as a primary reference measurement method such as for certification of serum Certified Reference Materials (CRMs)

  7. Optimisation of the determination of thiamin, 2-(1-hydroxyethyl)thiamin, and riboflavin in food samples by use of HPLC

    DEFF Research Database (Denmark)

    Jakobsen, Jette

    2008-01-01

    The aim of this study was first to optimise and validate a method using an enzyme-mixture to liberate protein- and phosphate-bound thiamin and riboflavin in food by the use of ultrasonication and HPLC, and second to include the quantitation of the vitamin B-1 active compound 2-(1-hydroxyethyl...

  8. Comparative HPLC/ESI-MS and HPLC/DAD study of different populations of cultivated, wild and commercial Gentiana lutea L.

    Science.gov (United States)

    Mustafa, Ahmed M; Caprioli, Giovanni; Ricciutelli, Massimo; Maggi, Filippo; Marín, Rosa; Vittori, Sauro; Sagratini, Gianni

    2015-05-01

    The root of Gentiana lutea L., famous for its bitter properties, is often used in alcoholic bitter beverages, food products and traditional medicine to stimulate the appetite and improve digestion. This study presents a new, fast, and accurate HPLC method using HPLC/ESI-MS and HPLC/DAD for simultaneous analysis of iridoids (loganic acid), secoiridoids (gentiopicroside, sweroside, swertiamarin, amarogentin) and xanthones (isogentisin) in different populations of G.lutea L., cultivated in the Monti Sibillini National Park, obtained wild there, or purchased commercially. Comparison of HPLC/ESI-MS and HPLC/DAD indicated that HPLC/ESI-MS is more sensitive, reliable and selective. Analysis of twenty samples showed that gentiopicroside is the most dominant compound (1.85-3.97%), followed by loganic acid (0.11-1.30%), isogentisin (0.03-0.48%), sweroside (0.05-0.35%), swertiamarin (0.08-0.30%), and amarogentin (0.01-0.07%). The results confirmed the high quality of the G.lutea cultivated in the Monti Sibillini National Park. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Expermental Studies of quantitative evaluation using HPLC

    Directory of Open Access Journals (Sweden)

    Ki Rok Kwon

    2005-06-01

    Full Text Available Methods : This study was conducted to carry out quantitative evaluation using HPLC Content analysis was done using HPLC Results : According to HPLC analysis, each BVA-1 contained approximately 0.36㎍ melittin, and BVA-2 contained approximately 0.54㎍ melittin. But the volume of coating was so minute, slight difference exists between each needle. Conclusion : Above results indicate that the bee venom acupuncture can complement shortcomings of syringe usage as a part of Oriental medicine treatment, but extensive researches should be done for further verification.

  10. A validated HPLC-MS/MS assay for quantifying unstable pharmacologically active metabolites of clopidogrel in human plasma: application to a clinical pharmacokinetic study.

    Science.gov (United States)

    Furlong, Michael T; Savant, Ishani; Yuan, Moucun; Scott, Laura; Mylott, William; Mariannino, Thomas; Kadiyala, Pathanjali; Roongta, Vikram; Arnold, Mark E

    2013-05-01

    Clopidogrel is prescribed for the treatment of Acute Coronary Syndrome and recent myocardial infarction, recent stroke, or established peripheral arterial disease. A sensitive and reliable high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay was developed and validated to enable reliable quantification of four diastereomeric and chemically reactive thiol metabolites, two of which are pharmacologically active, in human plasma. The metabolites were stabilized by alkylation of their reactive thiol moieties with 2-bromo-3'-methoxyacetophenone (MPB). Following organic solvent mediated-protein precipitation in a 96-well plate format, chromatographic separation was achieved by gradient elution on an Ascentis Express RP-amide column. Chromatographic conditions were optimized to ensure separation of the four derivatized active metabolites. Derivatized metabolites and stable isotope-labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The HPLC-MS/MS assay was validated over concentration ranges of 0.125-125 ng/mL for metabolites H1-H3 and 0.101-101 ng/mL for H4. Intra- and inter-assay precision values for replicate quality control samples were within 14.3% for all analytes during the assay validation. Mean quality control accuracy values were within ±6.3% of nominal values for all analytes. Assay recoveries were high (>79%). The four derivatized analytes were stable in human blood for at least 2 h at room temperature and on ice. The analytes were also stable in human plasma for at least 25 h at room temperature, 372 days at -20 °C and -70 °C, and following at least five freeze-thaw cycles. The validated assay was successfully applied to the quantification of all four thiol metabolites in human plasma in support of a human pharmacokinetic study. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Simultaneous HPLC quantitative analysis of mangostin derivatives in Tetragonula pagdeni propolis extracts

    Directory of Open Access Journals (Sweden)

    Sumet Kongkiatpaiboon

    2016-04-01

    Full Text Available Propolis has been used as indigenous medicine for curing numerous maladies. The one that is of ethnopharmacological use is stingless bee propolis from Tetragonula pagdeni. A simultaneous high-performance liquid chromatography (HPLC investigation was developed and validated to determine the contents of bioactive compounds: 3-isomangostin, gamma-mangostin, beta-mangostin, and alpha-mangostin. HPLC analysis was effectively performed using a Hypersil BDS C18 column, with the gradient elution of methanol–0.2% formic acid and a flow rate of 1 ml/min, at 25 °C and detected at 245 nm. Parameters for the validation included accuracy, precision, linearity, and limits of quantitation and detection. The developed HPLC technique was precise, with lower than 2% relative standard deviation. The recovery values of 3-isomangostin, gamma-mangostin, beta-mangostin, and alpha-mangostin in the extracts were 99.98%, 99.97%, 98.98% and 99.19%, respectively. The average contents of these mixtures in the propolis extracts collected from different seasons were 0.127%, 1.008%, 0.323% and 2.703% (w/w, respectively. The developed HPLC technique was suitable and practical for the simultaneous analysis of these mangostin derivatives in T. pagdeni propolis and would be a valuable guidance for the standardization of its pharmaceutical products.

  12. The integrated quality assessment of Chinese commercial dry red wine based on a method of online HPLC-DAD-CL combined with HPLC-ESI-MS.

    Science.gov (United States)

    Yu, Hai-Xiang; Sun, Li-Qiong; Qi, Jin

    2014-07-01

    To apply an integrated quality assessment strategy to investigate the quality of multiple Chinese commercial dry red wine samples. A comprehensive method was developed by combining a high performance liquid chromatography-diode array detector-chemiluminescence (HPLC-DAD-CL) online hyphenated system with an HPLC-ESI-MS technique. Chromatographic and H2O2-scavenging active fingerprints of thirteen batches of different, commercially available Chinese dry red wine samples were obtained and analyzed. Twenty-five compounds, including eighteen antioxidants were identified and evaluated. The dominant and characteristic antioxidants in the samples were identified. The relationships between antioxidant potency and the cultivated variety of grape, producing area, cellaring period, and trade mark are also discussed. The results provide the feasibility for an integrated quality assessment strategy to be efficiently and objectively used in quality (especially antioxidant activity) assessment and identification of dry red wine. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  13. Determination of Arctiin and Arctigenin Contents in Arctium Tomentosum Mill. by HPLC Method

    Directory of Open Access Journals (Sweden)

    Xiaoying Zhou

    2011-01-01

    Full Text Available A simple, precise, rapid and accurate, binary-phase high performance liquid chromatographic method has been developed for the determination of arctiin and arctigenin contents in the Arctium tomentosumMill. with short run time. Chromatographic separation was achieved by using HPLC system, consisting of a Shimadzu LC-6AD and Kromasil C18 column (250×4.6 mm, 5 μm, with pre-column, the mobile phase consists of methanol and water (55: 45. Detection wavelength was 280 nm. The speed of flow was 1.0 mL/min. The specimen handing quantity was 10 μL. The arctiin’s linearity range was 1.575∼4.725 μg (r=0.9995. The arctigenin’s linearity range was 0.613, 3.063 μg (r = 0.9998 and the linear relationship was accurate. The average recovery (n=5 of arctiin and arctigenin were 101.55% (RSD=2.23% 101.63% (RSD =1.49 % respectively. The contents of arctiin and arctigenin in Arctium tomentosum Mill. were 10.69 mg/g and 0.15 mg/g, respectively. Therefore, the developed HPLC method can be applied to both in vitro studies of arctiin and arctigenin formulations as well as drug estimation in biological samples.

  14. Methodology for determination of benzimidazolic fungicides residues in strawberry and lettuce by HPLC-DAD

    International Nuclear Information System (INIS)

    Dangond Araujo, Jose Jairo; Guerrero dallos, Jairo Arturo

    2006-01-01

    systemic fungicides like benzimidazolic compounds are used to protect several crops of fruits and vegetables. in this work a new method for analysis of Benomyl, carbendazim and thiabendazol in strawberry and lettuce by high performance liquid chromatography with diode array detector (HPLC-DAD) was validated. benomyl residues were determined after its conversion to carbendazim. pesticide residues were extracted from strawberry and lettuce samples with ethyl acetate and these extracts were cleaned up by gel permeation chromatography (GPC). final determination was carried out by HPLC-DAD in reverse phase column. the method is selective, specific, precise and accurate. the calibration curves show linearity over concentration range of 1.24 to 6.19 mg/kg, with detection limits of 0.40 and 0.27 mg/kg and quantification limits of 1.35 and 0.81 mg/kg for carbendazim and thiabendazole respectively. the recovery experiments yielding averages of 90 %. n o residues of these compounds were found in collected samples from specific areas of Cundinamarca, Colombia

  15. Application of Multi-Analyte Methods for Pesticide Formulations

    Energy Technology Data Exchange (ETDEWEB)

    Lantos, J.; Virtics, I. [Plant Protection & Soil Conservation Service of Szabolcs-Szatmár-Bereg County, Nyíregyháza (Hungary)

    2009-07-15

    The application of multi-analyte methods for pesticide formulations by GC analysis is discussed. HPLC was used to determine active ingredients. HPLC elution sequences were related to individual n-octanol/water partition coefficients. Real laboratory data are presented and evaluated with regard to validation requirements. The retention time data of pesticides on different HPLC columns under gradient and isocratic conditions are compared to illustrate the applicability of the methodologies. (author)

  16. Comparison of high-pressure liquid chromatography (HPLC) and Griess reagent-spectroscopic methods for the measurement of nitrate in serum from healthy individuals in the Nordic countries.

    Science.gov (United States)

    Larsen, Tine Lise; Nilsen, Valentina; Andersen, Dag Olav; Francis, George; Rustad, Pål; Mansoor, Mohammad Azam

    2008-12-01

    Bioavailability of NO can be estimated by measuring the concentration of nitrate (NO(3)) in serum. However, the methods used for the measurement NO(3) in plasma or serum show a great degree of variation. Therefore, we compared two analytical methods for the measurement of NO(3) in serum. The concentration of NO(3) in 600 serum samples collected from healthy individuals was determined by the HPLC and by the Griess reagent-spectroscopic method. The concentration of NO(3) in the samples was 29.4+/-16.1 micromol/L and 26.2+/-14.0 micromol/L (mean+/-SD) measured by HPLC and Griess reagent-spectroscopic method respectively (pHPLC method.

  17. Simultaneous determination of bioactive constituents in Danggui Buxue Tang for quality control by HPLC coupled with a diode array detector, an evaporative light scattering detector and mass spectrometry.

    Science.gov (United States)

    Yi, Ling; Qi, Lian-Wen; Li, Ping; Ma, Yi-Han; Luo, Yong-Jing; Li, Hai-Yun

    2007-09-01

    Danggui Buxue Tang (DBT), a classical traditional Chinese formula comprising Radix Angelicae Sinensis (RAS) and Radix Astragali (RA), has been widely used to treat menopausal irregularity in Chinese women for nearly 800 years. In this study, a comprehensive analytical method of simultaneously determining the main types of bioactive constituents, eighteen in all from the formula, involving flavonoids, saponins, organic acid and some volatile compounds, was developed. This method was based on HPLC coupled to a diode array and evaporative light scattering detectors (HPLC-DAD-ELSD) on a common reverse-phase C(18) column. Liquid chromatography coupled with on-line electrospray ionization mass spectrometry (LC-ESI-MS) was also used to further validate and analyze the constituents. It was found that 0.3% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution. This method, which showed good precision and accuracy, was successfully used to quantify the bioactive constituents in six products. As a result, the validated HPLC method, together with the LC-ESI-MS analysis, provided a new basis for assessing the quality of traditional Chinese medicinal compound preparations (TCMCPs) consisting of many bioactive components.

  18. RP-HPLC determination of water-soluble vitamins in honey.

    Science.gov (United States)

    Ciulu, Marco; Solinas, Silvia; Floris, Ignazio; Panzanelli, Angelo; Pilo, Maria I; Piu, Paola C; Spano, Nadia; Sanna, Gavino

    2011-01-15

    The assessment and validation of reliable analytical methods for the determination of vitamins in sugar-based matrices (e.g. honey) are still scarcely explored fields of research. This study proposes and fully validates a simple and fast RP-HPLC method for the simultaneous determination of five water-soluble vitamins (vitamin B(2), riboflavin; vitamin B(3), nicotinic acid; vitamin B(5), pantothenic acid; vitamin B(9), folic acid; and vitamin C, ascorbic acid) in honey. The method provides low detection and quantification limits, very good linearity in a large concentration interval, very good precision, and the absence of any bias. It has been successfully applied to 28 honey samples (mainly from Sardinia, Italy) of 12 different botanical origins. While the overall amount of the analytes in the samples is quite low (always below 40 mg kg(-1)), we have observed a marked dependence of some of their concentrations (i.e. vitamin B(3) and vitamin B(5)) and the botanical origin of the honey. This insight might lead to important characterization features for this food item. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Fast gradient HPLC method to determine compounds binding to human serum albumin. Relationships with octanol/water and immobilized artificial membrane lipophilicity.

    Science.gov (United States)

    Valko, Klara; Nunhuck, Shenaz; Bevan, Chris; Abraham, Michael H; Reynolds, Derek P

    2003-11-01

    A fast gradient HPLC method (cycle time 15 min) has been developed to determine Human Serum Albumin (HSA) binding of discovery compounds using chemically bonded protein stationary phases. The HSA binding values were derived from the gradient retention times that were converted to the logarithm of the equilibrium constants (logK HSA) using data from a calibration set of molecules. The method has been validated using literature plasma protein binding data of 68 known drug molecules. The method is fully automated, and has been used for lead optimization in more than 20 company projects. The HSA binding data obtained for more than 4000 compounds were suitable to set up global and project specific quantitative structure binding relationships that helped compound design in early drug discovery. The obtained HSA binding of known drug molecules were compared to the Immobilized Artificial Membrane binding data (CHI IAM) obtained by our previously described HPLC-based method. The solvation equation approach has been used to characterize the normal binding ability of HSA, and this relationship shows that compound lipophilicity is a significant factor. It was found that the selectivity of the "baseline" lipophilicity governing HSA binding, membrane interaction, and octanol/water partition are very similar. However, the effect of the presence of positive or negative charges have very different effects. It was found that negatively charged compounds bind more strongly to HSA than it would be expected from the lipophilicity of the ionized species at pH 7.4. Several compounds showed stronger HSA binding than can be expected from their lipophilicity alone, and comparison between predicted and experimental binding affinity allows the identification of compounds that have good complementarities with any of the known binding sites. Copyright 2003 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 92:2236-2248, 2003

  20. Comparative in vitro assessment of tolterodine tartrate tablets by high performance liquid chromatographic (HPLC

    Directory of Open Access Journals (Sweden)

    Hossein Danafar

    2016-06-01

    Full Text Available Tolterodine tartrate, is a new, potent and competitive muscarinic receptor antagonist in clinical development for the treatment of urge incontinence and other symptoms of unstable bladder. The purpose of this study is to establish a reliable and quick method for the assignment of tolterodine tartrate by high performance liquid chromatography with ultraviolet detection (HPLC-UV. A rapid  and  sensitive  high  performance  liquid  chromatographic  (HPLC  method  has  been developed  for  determination  of  tolterodine tartrate.  Mobile phase was composed of phosphate acetate 0.1 M (pH 2.5-acetonitrile (50:50 v/v with a flow rate of 1.2 ml/min. The eluted peaks were detected by a UV detector was set at wavelength of 285 nm. The method was validated in the range of tolterodine tartrate concentrations from 10 to 100 µg/ml. The limits of detection (LOD and quantitation (LOQ of the method were 5 and 10 µg/ml, respectively. The average drug recovery was 98.20 % throughout the linear concentration range. The average within-run and between-run accuracy values of 98.56 % and 99.11 % respectively. Statistical  assessment  of  various  in  vitro  dissolution  parameters  and  assay  results was  also  conducted  to  establish  if  there were  any significant difference among them. The validated HPLC method has been used successfully to study tolterodine tartrate.

  1. Determination of tocopheryl acetate and ascorbyl tetraisopalmitate in cosmetic formulations by HPLC.

    Science.gov (United States)

    Almeida, M M; Alves, J M P; Patto, D C S; Lima, C R R C; Quenca-Guillen, J S; Santoro, M I R M; Kedor-Hackmann, E R M

    2009-12-01

    A rapid HPLC method was developed for the assay of tocopheryl acetate and ascorbyl tetraisopalmitate in cosmetic formulations. The validated method was applied for quantitative determination of these vitamins in simulated emulsion formulation. Samples were analysed directly on a RP-18 reverse phase column with UV detection at 222 nm. A mixture of methanol and isopropanol (25 : 75 v/v) was used as mobile phase. The retention time of tocopheryl acetate and ascorbyl tetraisopalmitate were 3.0 min and 5.9 min, respectively. Recovery was between 95% and 104%. In addition, the excipients did not interfere in the analysis. The method is simple, reproducible, selective and is suitable for routine analyses of commercial products.

  2. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    Science.gov (United States)

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  3. Brief on -Hyphenated Methods of HPLC for Determining the Presence of Solutes.

    Directory of Open Access Journals (Sweden)

    Mohamad Taleuzzaman

    2017-02-01

    Full Text Available HPLC is the tool in liquid chromatography is unique because of particle size, smaller particle in the stationary phase, increase efficiency of a separation. However, if the particles are made smaller, capillary action increases and it becomes more difficult to drain the column under gravity. For quantitative analysis different types of detector is used in conjunction with HPLC which give precise and accurate result and it is apply according to the nature of the substance. Various types of detectors used in HPLC are mass spectrometry, infrared spectroscopy, visible spectroscopy, ultraviolet spectroscopy, fluorescence spectroscopy, nuclear magnetic resonance, conductivity measurement, and refractive index measurement. Each detector has its assets, limitations and sample types for which it is most effective. The recent development of the so-called hyphenated techniques has improved the ability to separate and identify multiple entities within a mixture.

  4. A new HPLC method for the detection of iodine applied to natural samples of edible seaweeds and commercial seaweed food products.

    Science.gov (United States)

    Nitschke, Udo; Stengel, Dagmar B

    2015-04-01

    Rich in micronutrients and considered to contain high iodine levels, seaweeds have multiple applications as food/supplements and nutraceuticals with potential health implications. Here, we describe the development and validation of a new analytical method to quantify iodine as iodide (I(-)) using an isocratic HPLC system with UV detection; algal iodine was converted to I(-) via dry alkaline incineration. The method was successfully applied to 19 macroalgal species from three taxonomic groups and five commercially available seaweed food products. Fesh kelps contained highest levels, reaching >1.0% per dry weight (DW), but concentrations differed amongst thallus parts. In addition to kelps, other brown (Fucales: ∼ 0.05% DW) and some red species (∼ 0.05% DW) can also serve as a rich source of iodine; lowest iodine concentrations were detected in green macroalgae (∼ 0.005% DW), implying that quantities recommended for seaweed consumption may require species-specific re-evaluation to reach adequate daily intake levels. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    Science.gov (United States)

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  6. Development and validation of a rapid HPLC- fluorescence method for simultaneous determination of venlafaxine and its major metabolites in human plasma

    Directory of Open Access Journals (Sweden)

    Y.H Ardakani

    2010-06-01

    Full Text Available "n Background and the purpose of the study:To develop a simple, rapid and accurate HPLC method for the measurement of the venlafaxine and its main metabolites, O-desmethylvenlafaxine and O,N-didesmethylvenlafaxine in pharmacokinetic studies and therapeutic drug monitoring.Method: Chromatographic separation was achieved with a ChromolithTM Performance RP-18e 100 mm×4.6 mm column equipped with a Fluorescence detectore (λex 200 nm/λem 300 nm The mobile phase of methanol:water (35:65, v/v adjusted to pH 2.5 by phosphoric acid was passed through the column in an isocratic mode at flow rate of 2 ml/min. The sample preparation involved a simple, one-step, extraction with ethyl acetate. "nResults:The calibration curves were linear in the concentration range of 1-300 ng/ml for all analytes (r2 > 0.998. The lower limit of quantification was 1 ng/ml for all analytes. Within and between day precisions in the measurement of quality control (QC of samples were in the range of 1.8-14.1% for all analytes. Conclusion:The developed procedure was used to assess the pharmacokinetics of venlafaxine and its main metabolites following oral administration of 75 mg venlafaxine to a healthy subject.

  7. UPLC and HPLC of caffeoyl esters in wild and cultivated Arctium lappa L.

    Science.gov (United States)

    Haghi, Ghasem; Hatami, Alireza; Mehran, Mehdi

    2013-05-01

    Analytical methods including ultra-performance liquid chromatography (UPLC) and high-performance liquid chromatography (HPLC) with photodiode array (PDA) detector were developed for the analysis of caffeoylquinic acid derivatives in seeds, leaves and roots of Arctium lappa L. Separation was performed on C(18) column utilising 5% (v/v) acetic acid in water and acetonitrile at 330 nm. Both methodologies were validated in terms of linearity, precision, and recovery. The results showed that the major advantages of UPLC, over HPLC were the fast analysis, narrow peaks, high sensitivity, and reduction of solvent consumption. Subsequently the methods were applied for the identification and quantification of chlorogenic acid (5-CQA) and 1,5-dicaffeoylquinic acid (1,5-DCQA) as main compounds in samples. The total phenolic content of samples ranged from 3.93 to 14.13 g of 5-CQA equivalent/100g dry weight (DW). There was a significant variability from 89 to 571 mg/100g for 5-CQA and 48 to 486 mg/100g for 1,5-DCQA in dry material. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. A validated stability-indicating high performance liquid chromatographic method for moxifloxacin hydrochloride and ketorolac tromethamine eye drops and its application in pH dependent degradation kinetics

    Directory of Open Access Journals (Sweden)

    Jayant B Dave

    2013-01-01

    Full Text Available Background and Aim: A fixed dose combination of moxifloxacin hydrochloride and ketorolac tromethamine is used in ratio of 1:1 as eye drops for the treatment of the reduction of post operative inflammatory conditions of the eye. A simple, precise, and accurate High Performance Liquid Chromatographic (HPLC method was developed and validated for determination of moxifloxacin hydrochloride and ketorolac tromethamine in eye drops. Materials and Methods: Isocratic HPLC separation was achieved on a ACE C 18 column (C 18 (5 μm, 150 mm×4.6 mm, i.d. using the mobile phase 10 mM potassium di-hydrogen phosphate buffer pH 4.6-Acetonitrile (75:25 v/v at a flow rate of 1.0 mL/min. The detection was performed at 307 nm. Drugs were subjected to acid, alkali and neutral hydrolysis, oxidation and photo degradation. Moreover, the proposed HPLC method was utilized to investigate the pH dependent degradation kinetics of moxifloxacin hydrochloride and ketorolac tromethamine in buffer solutions at different pH values like 2.0, 6.8 and 9.0. Results and Conclusion: The retention time (t R of moxifloxacin hydrochloride and ketorolac tromethamine were 3.81±0.01 and 8.82±0.02 min, respectively. The method was linear in the concentration range of 2-20 μ/mL each for moxifloxacin hydrochloride and ketorolac tromethamine with a correlation coefficient of 0.9996 and 0.9999, respectively. The method was validated for linearity, precision, accuracy, robustness, specificity, limit of detection and limit of quantitation. The drugs could be effectively separated from different degradation products and hence the method can be used for stability analysis. Different kinetics parameters like apparent first-order rate constant, half-life and t 90 (time for 90% potency left were calculated.

  9. A Simple and Improved HPLC-PDA Method for Simultaneous Estimation of Fexofenadine and Pseudoephedrine in Extended Release Tablets by Response Surface Methodology

    Directory of Open Access Journals (Sweden)

    Ruhul Kayesh

    2017-01-01

    Full Text Available A simple RP-HPLC method has been developed for simultaneous estimation of fexofenadine and pseudoephedrine in their extended release tablet. The method was developed based on statistical design of experiments (DoE and Response Surface Methodology. Separation was achieved on double end-capped C18 column (250 mm × 4 mm, 5 μm. In this experiment, two components of mobile phase, namely, acetonitrile (% v/v and methanol (% v/v, were the factors whereas retention and resolution of the chromatographic peaks were the responses. The effects of different composition of factors on the corresponding responses were investigated. The optimum chromatographic condition for the current case was found as an isocratic mobile phase consisting of 20 mM phosphate buffer (pH 6.8 and acetonitrile and methanol in a ratio of 50 : 36 : 14 (% v/v at a flow rate of 1 mL/min for 7 minutes. The retention of pseudoephedrine and fexofenadine was found to be 2.6 min and 4.7 min, respectively. The method was validated according to the ICH and FDA guidelines and various validation parameters were determined. Also, forced degradation studies in acid, base, oxidation, and reduction media and in thermal condition were performed to establish specificity and stability-indicating property of this method. Practical applicability of this method was checked in extended release tablets available in Bangladeshi market.

  10. 72 - 80_Aminu_HPLC1

    African Journals Online (AJOL)

    pc

    HPLC, Gymnema sylvestre, carbohydrate hydrolyzing enzymes, lipid a chronic .... Method. Test for Tannins and Flavonoids was by. Trease and Evans (2002). Soluble Starch ... Fenton reaction was quantified using 2- deoxyribose oxidative ...

  11. Heterozygote Hemoglobin G-Coushatta as the Cause of a Falsely Decreased Hemoglobin A1C in an Ion-Exchange HPLC Method

    Directory of Open Access Journals (Sweden)

    Kurtoğlu Ayşegül Uğur

    2017-09-01

    Full Text Available Glycated hemoglobin (HbA1c is used for the assessment of glycemic control in patients with diabetes. The presence of genetic variants of hemoglobin can profoundly affect the accuracy of HbA1c measurement. Here, we report two cases of Hemoglobin G-Coushatta (HBB:c.68A>C variant that interferes in the measurement of HbA1c by a cation-exchange HPLC (CE-HPLC method. HbA1c was measured by a CE-HPLC method in a Tosoh HLC-723 G7 instrument. The HbA1c levels were 2.9% and 4%. These results alerted us to a possible presence of hemoglobinopathy. In the hemoglobin variant analysis, HbA2 levels were detected as 78.3% and 40.7% by HPLC using the short program for the Biorad Variant II. HbA1c levels were measured by an immunoturbidimetric assay in a Siemens Dimension instrument. HbA1c levels were reported as 5.5% and 5.3%. DNA mutation analysis was performed to detect the abnormal hemoglobin variant. Presence of Hemoglobin G-Coushatta variant was detected in the patients. The Hb G-Coushatta variants have an impact on the determination of glycated hemoglobin levels using CEHPLC resulting in a false low value. Therefore, it is necessary to use another measurement method.

  12. RP-HPLC Determination of Atomoxetine Hydrochloride in Bulk and Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    H. R. Prajapati

    2011-01-01

    Full Text Available A reversed phase high performance liquid chromatographic (RP–HPLC method was developed and subsequently validated for the determination of atomoxetine hydrochloride in bulk and pharmaceutical formulation. The separation was done by a PerkinElmer Brownlee analytical C8 column (260 mm x 4.6 mm, 5 µm using methanol: 50 mM KH2PO2 buffer (PH adjusted to 6.8 with 0.1 M NaOH, 80:20 v/v as an eluent. UV detection was performed at 270 nm at a flow rate 1.0 mL/min. The validation of the method was performed, and specificity, reproducibility, precision accuracy and ruggedness were confirmed. The correlation coefficient was found to be 0.997 for atomoxetine hydrochloride. The recovery was in the range of 99.94 to 100.98% and limit of quantification was found to be 5.707 µg/mL. The method is simple, rapid, selective and economical too and can be used for the routine analysis of drug in pharmaceutical formulations.

  13. Analytical capabilities of high performance liquid chromatography - Atmospheric pressure photoionization - Orbitrap mass spectrometry (HPLC-APPI-Orbitrap-MS) for the trace determination of novel and emerging flame retardants in fish.

    Science.gov (United States)

    Zacs, D; Bartkevics, V

    2015-10-22

    A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called "emerging" and "novel" BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and where possible, trueness was verified by analysis of certified reference materials (CRMs). Recoveries of analytes were between 80 and 119%, while the repeatability in terms of relative standard deviations (RSDs) was in the range from 1.2 to 15.5%. The measured values for both analyzed CRMs agreed with the provided consensus values, revealing the recovery of reference concentrations in 72-119% range. The elaborated method met the sensitivity criterion according to Commission Recommendation 2014/118/EU on monitoring of BFRs in food products for majority of the compounds. The concentrations of polybrominated diphenyl ethers (PBDEs) in real samples determined by HPLC-APPI-Orbitrap-MS method and validated gas chromatography-high-resolution mass spectrometry (GC-HRMS) method were found to be in a good agreement. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Method Development for the Analysis of Pharmaceuticals with Acethylcholinesterase Activity in Water Using HPLC-DAD and Solid Phase Extraction

    Directory of Open Access Journals (Sweden)

    Samuel Budi Wardhana

    2014-03-01

    Full Text Available An SPE followed by HPLC-DAD method with ion pair chromatography technique to analyze pharmaceuticals with acethylcholinesterase activity including pyridostigmine (PYR, galathamine (GAL, neostigmine (NEO, eserine (ESE, and donepezil (DON in water samples was developed. Acetylcholinesterase (AChE inhibitors have been used to treat less severe dementias such as Alzheimer’s disease. Chromatographic separation was achieved using reversed-phase SymmetryShield column using gradient system with mobile phase consisting of H2O/ACN (99:1, v/v as mobile phase A with 10 mM sodium 1-hexanesulfonate and 0.1% acetic acid (HAc. The HPLC/DAD method was linear between concentrations of 5 to 100 ng/μL. The IDL and IQL ranged from 0.50 to 1.25 ng/μL and 1.5 to 3.0 ng/μL, respectively. SPE was used to extract and clean up the target substances in spiked pure water, tap water, and wastewater samples. The application of extraction method of 5 target substances in wastewater sample was divided into 2 parts: Oasis WCX (6 mL, 500 mg for PYR and Oasis HLB (6 mL, 200 mg for GAL, NEO, ESE and DON. The developed SPE and HPLC/DAD method is applicable for quantification of the 5 target substances in water samples in a concentration range > 50 µg/L and assumable lower for DON (> 25 µg/L.

  15. Determination of the design space of the HPLC analysis of water-soluble vitamins.

    Science.gov (United States)

    Wagdy, Hebatallah A; Hanafi, Rasha S; El-Nashar, Rasha M; Aboul-Enein, Hassan Y

    2013-06-01

    analysis of water-soluble vitamins by HPLC, which would help the regulatory authorities to judge the validity of presented analytical methods for approval. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Development and optimization of the determination of pharmaceuticals in water samples by SPE and HPLC with diode-array detection.

    Science.gov (United States)

    Pavlović, Dragana Mutavdžić; Ašperger, Danijela; Tolić, Dijana; Babić, Sandra

    2013-09-01

    This paper describes the development, optimization, and validation of a method for the determination of five pharmaceuticals from different therapeutic classes (antibiotics, anthelmintics, glucocorticoides) in water samples. Water samples were prepared using SPE and extracts were analyzed by HPLC with diode-array detection. The efficiency of 11 different SPE cartridges to extract the investigated compounds from water was tested in preliminary experiments. Then, the pH of the water sample, elution solvent, and sorbent mass were optimized. Except for optimization of the SPE procedure, selection of the optimal HPLC column with different stationary phases from different manufacturers has been performed. The developed method was validated using spring water samples spiked with appropriate concentrations of pharmaceuticals. Good linearity was obtained in the range of 2.4-200 μg/L, depending on the pharmaceutical with the correlation coefficients >0.9930 in all cases, except for ciprofloxacin (0.9866). Also, the method has revealed that low LODs (0.7-3.9 μg/L), good precision (intra- and interday) with RSD below 17% and recoveries above 98% for all pharmaceuticals. The method has been successfully applied to the analysis of production wastewater samples from the pharmaceutical industry. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    Science.gov (United States)

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  18. RP-HPLC Determination of vitamins B1, B3, B6, folic acid and B12 in multivitamin tablets

    Directory of Open Access Journals (Sweden)

    SOTE VLADIMIROV

    2005-10-01

    Full Text Available Abstract:Asimple and sensitive reversed-phase, ion-pair HPLC method was developed and validated for the simultaneous determination of B-group vitamins, thiamine chloride hydrochloride (B1, nicotinamide (B3, pyridoxine hydrochloride (B6 and folic acid in Pentovit® coated tablets. The cyanocobalamine (B12 was determined separately, because of its low concentration in the investigated multivitamin preparation. RP-HPLC analysis was performed with a LKB 2150 HPLC system, equipped with a UV/VIS Waters M484 detector. The procedures for the determination of B1, B2, B6 and folic acid were carried out on a Supelcosil ABZ+ (15 cm 4.6 mm; 5 µm column with methanol-5mM heptanesulphonic acid sodium salt 0.1%triethylamine TEA(25:75 V/V; pH 2.8 as themobile phase. For the determination of B12 a Suplex pKb-100 (15 cm 4.6 mm; 5 µm column andmethanol–water (22:78 V/V as themobile phase were used. The column effluentsweremonitored at 290 nm for B 1, B3, B6 and folic acid, and at 550 nm for B12. The obtained results and statistical parameters for all the investigated vitamins of the B-group in Pentovit® coated tablets were satisfactory and ranged from 90.4 % to 108.5 % (RSD. from 0.5% to 4.1 %. The parameters for the validation of the methods are given.

  19. Development and Validation of Liquid Chromatographic Method for Estimation of Naringin in Nanoformulation

    Directory of Open Access Journals (Sweden)

    Kranti P. Musmade

    2014-01-01

    Full Text Available A simple, precise, accurate, rapid, and sensitive reverse phase high performance liquid chromatography (RP-HPLC method with UV detection has been developed and validated for quantification of naringin (NAR in novel pharmaceutical formulation. NAR is a polyphenolic flavonoid present in most of the citrus plants having variety of pharmacological activities. Method optimization was carried out by considering the various parameters such as effect of pH and column. The analyte was separated by employing a C18 (250.0 × 4.6 mm, 5 μm column at ambient temperature in isocratic conditions using phosphate buffer pH 3.5: acetonitrile (75 : 25% v/v as mobile phase pumped at a flow rate of 1.0 mL/min. UV detection was carried out at 282 nm. The developed method was validated according to ICH guidelines Q2(R1. The method was found to be precise and accurate on statistical evaluation with a linearity range of 0.1 to 20.0 μg/mL for NAR. The intra- and interday precision studies showed good reproducibility with coefficients of variation (CV less than 1.0%. The mean recovery of NAR was found to be 99.33 ± 0.16%. The proposed method was found to be highly accurate, sensitive, and robust. The proposed liquid chromatographic method was successfully employed for the routine analysis of said compound in developed novel nanopharmaceuticals. The presence of excipients did not show any interference on the determination of NAR, indicating method specificity.

  20. Single-laboratory validation of a saponification method for the determination of four polycyclic aromatic hydrocarbons in edible oils by HPLC-fluorescence detection.

    Science.gov (United States)

    Akdoğan, Abdullah; Buttinger, Gerhard; Wenzl, Thomas

    2016-01-01

    An analytical method is reported for the determination of four polycyclic aromatic hydrocarbons (benzo[a]pyrene (BaP), benz[a]anthracene (BaA), benzo[b]fluoranthene (BbF) and chrysene (CHR)) in edible oils (sesame, maize, sunflower and olive oil) by high-performance liquid chromatography. Sample preparation is based on three steps including saponification, liquid-liquid partitioning and, finally, clean-up by solid phase extraction on 2 g of silica. Guidance on single-laboratory validation of the proposed analysis method was taken from the second edition of the Eurachem guide on method validation. The lower level of the working range of the method was determined by the limits of quantification of the individual analytes, and the upper level was equal to 5.0 µg kg(-1). The limits of detection and quantification of the four PAHs ranged from 0.06 to 0.12 µg kg(-1) and from 0.13 to 0.24 µg kg(-1). Recoveries of more than 84.8% were achieved for all four PAHs at two concentration levels (2.5 and 5.0 µg kg(-1)), and expanded relative measurement uncertainties were below 20%. The performance of the validated method was in all aspects compliant with provisions set in European Union legislation for the performance of analytical methods employed in the official control of food. The applicability of the method to routine samples was evaluated based on a limited number of commercial edible oil samples.

  1. Alternative method to determine Specific Activity of (177)Lu by HPLC.

    Science.gov (United States)

    Breeman, Wouter A P; de Zanger, Rory M S; Chan, Ho Sze; de Blois, Erik

    2015-01-01

    Peptide Receptor Radionuclide Therapy (PRRT) with (177)Lu-DOTA-peptides requires (177)Lu with high specific activity (SA) and values >740 GBq (177)Lu per mg Lu to maximise the atom% of (177)Lu over total Lu. Vendors provide SA values which are based on activity and mass of the target, whereas due to "burn-up" of target, these SA values are not accurate. For a radiochemist the SA of (177)Lu is of interest prior to radiolabeling. An alternative method to determine SA was developed by HPLC, which includes a metal titration of a known amount of DOTA-peptide with a known amount of activity ((177)Lu), and a unknown amount of metal ((177+nat)Lu). Based on an HPLC separation of radiometal-DOTA-peptide and DOTA-peptide, and the concordant ratio of these components the metal content ((177+nat)Lu) can be calculated, and eventually the SA of (177)Lu can be accurately determined. These experimentally determined SA values exceeded the estimated values provided by vendors by 27 ± 16%, (range 6-73 %). The deviation of SA values for samples from the same Lu batch was <2% (n ≥ 10). the SA of (177)Lu is apparently often higher as stated by vendors in comparison to the experimentally determined actual values. For this reason, the SA of (177)Lu-DOTA-TATE and other Lu-DOTA-peptides could be increased accordingly.

  2. HPLC determination of betamethasone and prednisolone in urine samples using monolithic column

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.

    2011-01-01

    A fast and reliable HPLC method is reported for the separation and quantification of betamethasone and prednisolone in urine samples using Chromolith at the rate of Performance RP-l8e (100 mm x 4.6 mm) column. The separation and detection was achieved using an isocratic mobile phase composed of methanol:water (44:56 v/v) at 2.0 mL/min and wavelength of 254 nm. After successful optimisation of method parameters, it was applied to the urine samples. Solid phase extraction technique was used to clean the sample before analysis. The developed method was validated for the system suitability, precision and accuracy. The limits of defection for the prednisolone and betamethasone are 0.11 ng and 0.075 ng/10 macro L injection, respectively allowing their determination in human urine samples. Recovery for spiked urine samples was in the range of 97-103 %. The method offers a valuable alternative to the methodologies currently employed for separation and quantification of prednisolone and betamethasone in urine samples. A fast and reliable HPLC method is reported for the separation and quantification of betamethasone and prednisolone in urine samples using Chromolith at the rate of Performance RP-l8e (100 mm x 4.6 mm) column. The separation and detection was achieved using an isocratic mobile phase composed of methanol:water (44:56 v/v) at 2.0 mL/min and wavelength of 254 nm. After successful optimisation of method parameters, it was applied to the urine samples. Solid phase extraction technique was used to clean the sample before analysis. The developed method was validated for the system suitability, precision and accuracy. The limits of defection for the prednisolone and betamethasone are 0.11 ng and 0.075 ng/10 macro L injection, respectively allowing their determination in human urine samples. Recovery for spiked urine samples was in the range of 97-103 %. The method offers a valuable alternative to the methodologies currently employed for separation and quantification

  3. Determination of Arctiin and Arctigenin Contents in Arctium Tomentosum Mill. by HPLC Method

    OpenAIRE

    Xiaoying Zhou; Haoke Zhang; Liang Ge; Haiyan Gong; Shuge Tian

    2011-01-01

    A simple, precise, rapid and accurate, binary-phase high performance liquid chromatographic method has been developed for the determination of arctiin and arctigenin contents in the Arctium tomentosumMill. with short run time. Chromatographic separation was achieved by using HPLC system, consisting of a Shimadzu LC-6AD and Kromasil C18 column (250×4.6 mm, 5 μm, with pre-column), the mobile phase consists of methanol and water (55: 45). Detection wavelength was 280 nm. The speed of flow was 1....

  4. Simultaneous determination of sesquiterpenes and pyrrolizidine alkaloids from the rhizomes of Petasites hybridus (L.) G.M. et Sch. and dietary supplements using UPLC-UV and HPLC-TOF-MS methods.

    Science.gov (United States)

    Avula, Bharathi; Wang, Yan-Hong; Wang, Mei; Smillie, Troy J; Khan, Ikhlas A

    2012-11-01

    UPLC-UV and HPLC-TOF-MS methods have been developed for the analysis of major sesquiterpenes and pyrrolizidine alkaloids from rhizomes of Petasites hybridus (L.) G.M. et Sch. (Family, Asteracea) and dietary supplements claiming to contain P. hybridus. The best results were obtained with Acquity UPLC™ HSS T3 (100 mm × 2.1 mm, I.D., 1.8 μm) column system using a gradient elution with a mobile phase consisting of ammonium formate (50mM) and acetonitrile (0.05% formic acid) at a constant flow rate of 0.25 mL/min via UPLC-UV. The newly developed method was validated according to the ICH guidelines with respect to specificity, linearity, accuracy and precision. The limits of detection were found to be 5 μg/mL and 0.1 μg/mL for pyrrolizidine alkaloids and sesquiterpenes, respectively by UPLC-UV and 0.001 and 0.01 μg/mL, respectively using HPLC-TOF-MS. The methods were successfully used to analyze different P. hybridus market products, as well as to distinguish between two other Petasites species. The total content of petasins was found to be in the range of 0.02-11.6 mg/dosage form for 15 dietary supplements and no petasins were detected in an additional six dietary supplements. Additionally, pyrrolizidine alkaloids, which are considered to be toxic for the liver, were detected in seven dietary supplements. The amount of petasin in seven dietary supplements was found to be within limits of label claim and no pyrrolizidine alkaloids were detected. HPLC-mass spectrometry coupled with electrospray ionization (ESI) interface method is described for the identification and confirmation of sesquiterpenes and pyrrolizidine alkaloids from plant extracts and dietary supplements that claim to contain P. hybridus as well as different species of Petasites. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Improved method for reliable HMW-GS identification by RP-HPLC and SDS-PAGE in common wheat cultivars

    Science.gov (United States)

    The accurate identification of alleles for high-molecular weight glutenins (HMW-GS) is critical for wheat breeding programs targeting end-use quality. RP-HPLC methods were optimized for separation of HMW-GS, resulting in enhanced resolution of 1By and 1Dx subunits. Statistically significant differe...

  6. On-line radioactivity detector for HPLC

    International Nuclear Information System (INIS)

    Kessler, M.J.

    1986-01-01

    Over the last ten years the technique of high performance liquid chromotography (HPLC) has become extensively employed for the separation and quantitation of various biological, organic, and inorganic substances. The use of HPLC for the separation of various metabolic compounds has become routine. The major problem of analyzing the metabolism process is that the quantitation is accomplished by the use of radioactive substrates. Until recently the only method to quantitate these radioactive compounds eluting from the HPLC was by collecting fractions at preset times, removing aliquots and quantitating in a liquid scintillation counter. Once the radioactivity present in each fraction was determined, the results were plotted on a graph and the area of each of the radioactive peaks was determined. This entire process required from 3-20 hours. The introduction of the flow through radioactivity detector enable the investigator to directly quantitate the radioactive peaks as they elute from the HPLC in real time and at about one-tenth the original cost of the previous methods. The detection limits of this technique are dependent on the residence time of the sample in the flow cell and the type of flow cell used for the analysis. Using a 2.5 ml liquid flow cell, (mixing with liquid scintillation solution), base line resolution can be obtained for peaks 1.5 minutes apart, and a sensitivity of 70 dpm for tritium and 30 dpm for carbon-14 can be achieved

  7. Development and Application of Multidimensional HPLC Mapping Method for O-linked Oligosaccharides

    Directory of Open Access Journals (Sweden)

    Koichi Kato

    2011-12-01

    Full Text Available Glycosylation improves the solubility and stability of proteins, contributes to the structural integrity of protein functional sites, and mediates biomolecular recognition events involved in cell-cell communications and viral infections. The first step toward understanding the molecular mechanisms underlying these carbohydrate functionalities is a detailed characterization of glycan structures. Recently developed glycomic approaches have enabled comprehensive analyses of N-glycosylation profiles in a quantitative manner. However, there are only a few reports describing detailed O-glycosylation profiles primarily because of the lack of a widespread standard method to identify O-glycan structures. Here, we developed an HPLC mapping method for detailed identification of O-glycans including neutral, sialylated, and sulfated oligosaccharides. Furthermore, using this method, we were able to quantitatively identify isomeric products from an in vitro reaction catalyzed by N-acetylglucosamine-6O-sulfotransferases and obtain O-glycosylation profiles of serum IgA as a model glycoprotein.

  8. HPLC method for determination of SN-38 content and SN-38 entrapment efficiency in a novel liposome-based formulation, LE-SN38.

    Science.gov (United States)

    Xuan, Tong; Zhang, J Allen; Ahmad, Imran

    2006-05-03

    A simple HPLC method was developed for quantification of SN-38, 7-ethyl-10-hydroxycamptothecin, in a novel liposome-based formulation (LE-SN38). The chromatographic separation was achieved on an Agilent Zorbax SB-C18 (4.6 mmx250 mm, 5 microm) analytical column using a mobile phase consisting of a mixture of NaH2PO4 (pH 3.1, 25 mM) and acetonitrile (50:50, v/v). SN-38 was detected at UV wavelength of 265 nm and quantitatively determined using an external calibration method. The limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.05 and 0.25 microg/mL, respectively. The individual spike recovery of SN-38 ranged from 100 to 101%. The percent of relative standard deviation (%R.S.D.) of intra-day and inter-day analyses were less than 1.6%. The method validation results confirmed that the method is specific, linear, accurate, precise, robust and sensitive for its intended use. The current method was successfully applied to the determination of SN-38 content and drug entrapment efficiency in liposome-based formulation, LE-SN38 during early stage formulation development.

  9. Determination of ursolic acid and ursolic acid lactone in the leaves of Eucalyptus tereticornis by HPLC

    International Nuclear Information System (INIS)

    Maurya, Anupam; Srivastava, Santosh Kumar

    2012-01-01

    A simple isocratic HPLC method has been developed for the simultaneous quantification of two bioactive triterpenes, ursolic acid and ursolic acid lactone in E. tereticornis leaves. Samples were analyzed on RP-18 (4.6 x 250 mm, 5 m u m ) column with methanol and water acidified to pH 3.5 with TFA (88:12) at 210 nm. The method was validated and applied for the simultaneous quantification of the individual triterpenes in E. tereticornis extract. The calibration curves were linear over a concentration range of 0.05-0.3 mg mL -1 (r = 0.999 and 0.998, respectively). The limits of detection and quantification were 0.190 and 0.644 μg for ursolic acid, and 0.176 and 0.587 μg for ursolic acid lactone, while the percentage recoveries were 97.32 and 96.23% for ursolic acid and ursolic acid lactone, respectively. This is the first report on the HPLC method of ursolic acid lactone with high precision and accuracy. (author)

  10. Determination of ursolic acid and ursolic acid lactone in the leaves of Eucalyptus tereticornis by HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Maurya, Anupam; Srivastava, Santosh Kumar [Analytical Chemistry Division, Central Institute of Medicinal and Aromatic Plants, Lucknow (India)

    2012-03-15

    A simple isocratic HPLC method has been developed for the simultaneous quantification of two bioactive triterpenes, ursolic acid and ursolic acid lactone in E. tereticornis leaves. Samples were analyzed on RP-18 (4.6 x 250 mm, 5 {sup m}u{sup m}) column with methanol and water acidified to pH 3.5 with TFA (88:12) at 210 nm. The method was validated and applied for the simultaneous quantification of the individual triterpenes in E. tereticornis extract. The calibration curves were linear over a concentration range of 0.05-0.3 mg mL{sup -1} (r = 0.999 and 0.998, respectively). The limits of detection and quantification were 0.190 and 0.644 {mu}g for ursolic acid, and 0.176 and 0.587 {mu}g for ursolic acid lactone, while the percentage recoveries were 97.32 and 96.23% for ursolic acid and ursolic acid lactone, respectively. This is the first report on the HPLC method of ursolic acid lactone with high precision and accuracy. (author)

  11. Chemical Differentiation of Dendrobium officinale and Dendrobium devonianum by Using HPLC Fingerprints, HPLC-ESI-MS, and HPTLC Analyses

    Science.gov (United States)

    Ye, Zi; Dai, Jia-Rong; Zhang, Cheng-Gang; Lu, Ye; Wu, Lei-Lei; Gong, Amy G. W.; Wang, Zheng-Tao

    2017-01-01

    The stems of Dendrobium officinale Kimura et Migo (Dendrobii Officinalis Caulis) have a high medicinal value as a traditional Chinese medicine (TCM). Because of the limited supply, D. officinale is a high priced TCM, and therefore adulterants are commonly found in the herbal market. The dried stems of a closely related Dendrobium species, Dendrobium devonianum Paxt., are commonly used as the substitute; however, there is no effective method to distinguish the two Dendrobium species. Here, a high performance liquid chromatography (HPLC) method was successfully developed and applied to differentiate D. officinale and D. devonianum by comparing the chromatograms according to the characteristic peaks. A HPLC coupled with electrospray ionization multistage mass spectrometry (HPLC-ESI-MS) method was further applied for structural elucidation of 15 flavonoids, 5 phenolic acids, and 1 lignan in D. officinale. Among these flavonoids, 4 flavonoid C-glycosides were firstly reported in D. officinale, and violanthin and isoviolanthin were identified to be specific for D. officinale compared with D. devonianum. Then, two representative components were used as chemical markers. A rapid and reliable high performance thin layer chromatography (HPTLC) method was applied in distinguishing D. officinale from D. devonianum. The results of this work have demonstrated that these developed analytical methods can be used to discriminate D. officinale and D. devonianum effectively and conveniently. PMID:28769988

  12. Semi-preparative HPLC preparation and HPTLC quantification of tetrahydroamentoflavone as marker in Semecarpus anacardium and its polyherbal formulations.

    Science.gov (United States)

    Aravind, S G; Arimboor, Ranjith; Rangan, Meena; Madhavan, Soumya N; Arumughan, C

    2008-11-04

    Application of modern scientific knowledge coupled with sensitive analytical technique is important for the quality evaluation and standardization of polyherbal formulations. Semecarpus anacardium, an important medicinal plant with wide medicinal properties, is frequently used in a large number of traditional herbal preparations. Tetrahydroamentoflavone (THA), a major bioactive biflavonoid was selected as a chemical marker of S. anacardium and RP-semi-preparative HPLC conditions were optimized for the isolation of tetrahydroamentoflavone. HPTLC analytical method was developed for the fingerprinting of S. anacardium flavonoids and quantification of tetrahydroamentoflavone. The method was validated in terms of their linearity, LOD, LOQ, precision and accuracy and compared with RP-HPLC-DAD method. The methods were demonstrated for the chemical fingerprinting of S. anacardium plant parts and some commercial polyherbal formulations and the amount of tetrahydroamentoflavone was quantified. HPTLC analysis showed that S. anacardium seed contained approximately 10 g kg(-1) of tetrahydroamentoflavone. The methods were able to identify and quantify tetrahydroamentoflavone from complex mixtures of phytochemicals and could be extended to the marker-based standardization of polyherbal formulations, containing S. anacardium.

  13. OPTIMIZATION OF A HPLC ANALYSIS METHOD FOR TAURINE AND CAFFEINE IN ENERGY DRINKS

    Directory of Open Access Journals (Sweden)

    RALUCA-IOANA [CHIRITA] TAMPU

    2018-03-01

    Full Text Available This paper presents the optimization of a rapid, inexpensive, reliable and selective isocratic high performance liquid chromatographic (HPLC method for the simultaneous determination of caffeine and taurine in energy drinks with two common detectors in series: evaporating light scattering detector (ELSD and an ultraviolet (UV detector. Satisfactory analysis results were obtained on an Astec apHera NH2 column using methanol/water (30:70 v/v as mobile phase. The optimized method was used for the analysis of commercial energy drinks containing large amounts of carbohydrates (100 g·L-1 and considerably lower amounts of taurine and caffeine (4 and 0.6 g·L-1, respectively. The advantages of this method consist of its lack of preliminary samples treatment and also the fact that basic LC instrumentation was employed.

  14. Development of a high performance liquid chromatography method ...

    African Journals Online (AJOL)

    Development of a high performance liquid chromatography method for simultaneous ... Purpose: To develop and validate a new low-cost high performance liquid chromatography (HPLC) method for ..... Several papers have reported the use of ...

  15. Stability indicating HPLC-DAD method for analysis of Ketorolac binary and ternary mixtures in eye drops: Quantitative analysis in rabbit aqueous humor.

    Science.gov (United States)

    El Yazbi, Fawzy A; Hassan, Ekram M; Khamis, Essam F; Ragab, Marwa A A; Hamdy, Mohamed M A

    2017-11-15

    Ketorolac tromethamine (KTC) with phenylephrine hydrochloride (PHE) binary mixture (mixture 1) and their ternary mixture with chlorpheniramine maleate (CPM) (mixture 2) were analyzed using a validated HPLC-DAD method. The developed method was suitable for the in vitro as well as quantitative analysis of the targeted mixtures in rabbit aqueous humor. The analysis in dosage form (eye drops) was a stability indicating one at which drugs were separated from possible degradation products arising from different stress conditions (in vitro analysis). For analysis in aqueous humor, Guaifenesin (GUF) was used as internal standard and the method was validated according to FDA regulation for analysis in biological fluids. Agilent 5 HC-C18(2) 150×4.6mm was used as stationary phase with a gradient eluting solvent of 20mM phosphate buffer pH 4.6 containing 0.2% triethylamine and acetonitrile. The drugs were resolved with retention times of 2.41, 5.26, 7.92 and 9.64min for PHE, GUF, KTC and CPM, respectively. The method was sensitive and selective to analyze simultaneously the three drugs in presence of possible forced degradation products and dosage form excipients (in vitro analysis) and also with the internal standard, in presence of aqueous humor interferences (analysis in biological fluid), at a single wavelength (261nm). No extraction procedure was required for analysis in aqueous humor. The simplicity of the method emphasizes its capability to analyze the drugs in vivo (in rabbit aqueous humor) and in vitro (in pharmaceutical formulations). Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Carotenoids from Foods of Plant, Animal and Marine Origin: An Efficient HPLC-DAD Separation Method

    Directory of Open Access Journals (Sweden)

    Irini F. Strati

    2012-12-01

    Full Text Available Carotenoids are important antioxidant compounds, present in many foods of plant, animal and marine origin. The aim of the present study was to describe the carotenoid composition of tomato waste, prawn muscle and cephalothorax and avian (duck and goose egg yolks through the use of a modified gradient elution HPLC method with a C30 reversed-phase column for the efficient separation and analysis of carotenoids and their cis-isomers. Elution time was reduced from 60 to 45 min without affecting the separation efficiency. All-trans lycopene predominated in tomato waste, followed by all-trans-β-carotene, 13-cis-lutein and all-trans lutein, while minor amounts of 9-cis-lutein, 13-cis-β-carotene and 9-cis-β-carotene were also detected. Considering the above findings, tomato waste is confirmed to be an excellent source of recovering carotenoids, especially all-trans lycopene, for commercial use. Xanthophylls were the major carotenoids of avian egg yolks, all-trans lutein and all-trans zeaxanthin in duck and goose egg yolk, respectively. In the Penaeus kerathurus prawn, several carotenoids (zeaxanthin, all-trans-lutein, canthaxanthin, cryptoxanthin, optical and geometrical astaxanthin isomers were identified in considerable amounts by the same method. A major advantage of this HPLC method was the efficient separation of carotenoids and their cis-isomers, originating from a wide range of matrices.

  17. A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC).

    Science.gov (United States)

    Grosser, Katharina; van Dam, Nicole M

    2017-03-15

    Glucosinolates are a well-studied and highly diverse class of natural plant compounds. They play important roles in plant resistance, rapeseed oil quality, food flavoring, and human health. The biological activity of glucosinolates is released upon tissue damage, when they are mixed with the enzyme myrosinase. This results in the formation of pungent and toxic breakdown products, such as isothiocyanates and nitriles. Currently, more than 130 structurally different glucosinolates have been identified. The chemical structure of the glucosinolate is an important determinant of the product that is formed, which in turn determines its biological activity. The latter may range from detrimental (e.g., progoitrin) to beneficial (e.g., glucoraphanin). Each glucosinolate-containing plant species has its own specific glucosinolate profile. For this reason, it is important to correctly identify and reliably quantify the different glucosinolates present in brassicaceous leaf, seed, and root crops or, for ecological studies, in their wild relatives. Here, we present a well-validated, targeted, and robust method to analyze glucosinolate profiles in a wide range of plant species and plant organs. Intact glucosinolates are extracted from ground plant materials with a methanol-water mixture at high temperatures to disable myrosinase activity. Thereafter, the resulting extract is brought onto an ion-exchange column for purification. After sulfatase treatment, the desulfoglucosinolates are eluted with water and the eluate is freeze-dried. The residue is taken up in an exact volume of water, which is analyzed by high-pressure liquid chromatography (HPLC) with a photodiode array (PDA) or ultraviolet (UV) detector. Detection and quantification are achieved by conducting comparisons of the retention times and UV spectra of commercial reference standards. The concentrations are calculated based on a sinigrin reference curve and well-established response factors. The advantages and

  18. A validated stability-indicating HPLC method for the simultaneous determination of pheniramine maleate and naphazoline hydrochloride in pharmaceutical formulations.

    Science.gov (United States)

    Huang, Taomin; Chen, Nianzu; Wang, Donglei; Lai, Yonghua; Cao, Zhijuan

    2014-02-01

    A simple, rapid, and accurate stability-indicating reverse phase liquid chromatographic method was developed and validated for the simultaneous determination of pheniramine maleate and naphazoline hydrochloride in bulk drugs and pharmaceutical formulations. Optimum chromatographic separations among pheniramine maleate, naphazoline hydrochloride and stress-induced degradation products have been achieved within 10 minutes by using an Agilent zorbax eclipse XDB C18 column (150 mm × 4.6 mm, 5 μm) as the stationary phase with a mobile phase consisted of 10 mM phosphate buffer pH 2.8 containing 0.5% triethlamine and methanol (68:32, v/v) at a flow rate of 1 mL min-1. Detection was performed at 280 nm using a diode array detector. Theoretical plates for pheniramine maleate and naphazoline hydrochloride were calculated to be 6762 and 6475, respectively. The method was validated in accordance with ICH guidelines with respect to linearity, accuracy, precision, robustness, specificity, limit of detection and quantitation. Regression analysis showed good correlations (R2 > 0.999) for pheniramine maleate in the concentration range of 150-1200 μg mL-1 and naphazoline hydrochloride in 12.5-100 μg mL-1. The method results in excellent separation of both the analytes and degradation products. The peak purity factor is ≥980 for both analytes after all types of stress, indicating complete separation of both analyte peaks from the stress induced degradation products. Overall, the proposed stability-indicating method was suitable for routine quality control and drug analysis of pheniramine maleate and naphazoline hydrochloride in pharmaceutical formulations.

  19. Determination of hydroxyurea in human plasma by HPLC-UV using derivatization with xanthydrol.

    Science.gov (United States)

    Legrand, Tiphaine; Rakotoson, Marie-Georgine; Galactéros, Frédéric; Bartolucci, Pablo; Hulin, Anne

    2017-10-01

    A simple and rapid high performance liquid chromatography (HPLC) method using ultraviolet (UV) detection was developed to determine hydroxyurea (HU) concentration in plasma sample after derivatization with xanthydrol. Two hundred microliters samples were spiked with methylurea (MeU) as internal standard and proteins were precipitated by adding methanol. Derivatization of HU and MeU was immediately performed by adding 0.02M xanthydrol and 1.5M HCl in order to obtain xanthyl-derivatives of HU and MeU that can be further separated using HPLC and quantified using UV detection at 240nm. Separation was achieved using a C18 column with a mobile phase composed of 20mM ammonium acetate and acetonitrile in gradient elution mode at a flow rate of 1mL/min. The total analysis time did not exceed 18min. The method was found linear from 5 to 400μM and all validation parameters fulfilled the international requirements. Between- and within-run accuracy error ranged from -4.7% to 3.2% and precision was lower than 12.8%. This simple method requires small volume samples and can be easily implemented in most clinical laboratories to develop pharmacokinetics studies of HU and to promote its therapeutic monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A high-throughput method for the simultaneous determination of multiple mycotoxins in human and laboratory animal biological fluids and tissues by PLE and HPLC-MS/MS.

    Science.gov (United States)

    Cao, Xiaoqin; Wu, Shuangchan; Yue, Yuan; Wang, Shi; Wang, Yuting; Tao, Li; Tian, Hui; Xie, Jianmei; Ding, Hong

    2013-12-30

    A high-throughput method for the determination of 28 mycotoxins involving pressurised liquid extraction (PLE) coupled with liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been optimised and validated for determination in various biological fluids and tissues of human and laboratory animals. High-throughput analysis was achieved using PLE pre-treatment and without the need for any cleanup. The extraction solvent was acetonitrile/water/acetic acid (80/19/1, v/v/v). The static extraction time was 5min. The extraction pressure and temperature were 1500psi and 140°C, respectively. The flush volume was 60%. The limits of detection, which were defined as CCα, varied from 0.01μg/kg (μg/L) to 0.69μg/kg (μg/L). The recoveries of spiked samples from 0.20μg/kg (μg/L) to 2μg/kg (μg/L) ranged from 71% to 100.5% with relative standard deviations of less than 17.5%, except FB1 and FB2 recoveries, which were lower than 60%. The method was successfully applied in real samples, and the data indicate that this technique is a useful analytical method for the determination of mycotoxins from humans and animals. To the best of our knowledge, this method is the first for the large-scale testing of multi-class mycotoxins in all types of biological fluids and tissues that uses PLE and HPLC-MS/MS. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Simultaneous determination of 15 phenolic constituents of Chinese black rice wine by HPLC-MS/MS with SPE.

    Science.gov (United States)

    Wang, Yutang; Liu, Yuanyuan; Xiao, Chunxia; Liu, Laping; Hao, Miao; Wang, Jianguo; Liu, Xuebo

    2014-06-01

    This study established a new method for quantitative and qualitative determination of certain components in black rice wine, a traditional Chinese brewed wine. Specifically, we combined solid-phase extraction and high-performance liquid chromatography (HPLC) with triple quadrupole mass spectrometry (MS/MS) to determine 8 phenolic acids, 3 flavonols, and 4 anthocyanins in black rice wine. First, we clean samples with OASIS HLB cartridges and optimized extraction parameters. Next, we performed separation on a SHIM-PACK XR-ODS column (I.D. 3.0 mm × 75 mm, 2.2 μm particle size) with a gradient elution of 50% aqueous acetonitrile (V/V) and water, both containing 0.2% formic acid. We used multiple-reaction monitoring scanning for quantification, with switching electrospray ion source polarity between positive and negative modes in a single chromatographic run. We detected 15 phenolic compounds properly within 38 min under optimized conditions. Limits of detection ranged from 0.008 to 0.030 mg/L, and average recoveries ranged from 60.8 to 103.1% with relative standard deviation ≤8.6%. We validated the method and found it to be sensitive and reliable for quantifying phenolic compounds in rice wine matrices. This study developed a new, reliable HPLC-MS/MS method for simultaneous determination of 15 bioactive components in black rice wine. This method was validated and found to be sensitive and reliable for quantifying phenolic compounds in rice wine. © 2014 Institute of Food Technologists®

  2. HPLC-RID-DAD-MS analysis of 18F-Fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Macasek, F.; Buriova, E.; Bruder, P.

    2001-01-01

    Objective of new method of FDG analysis development is to replace existing tests by more complex assay. In this work, a liquid chromatography/refractive index detector/diode array detector/mass spectrometric detector combination (HPLC/RID/DAD/MSD) was used for development of a complex routine technique. Optimization of the HPLC/MS analysis was performed investigating MSD analytical signal as a function of various eluent composition. HPLC-RID-DAD-MSD analysis has potentiality of a complex quality control of radiopharmaceuticals, FDG in particular, providing information about: isotope composition; chemical composition; biochemical composition; radiation stability; pharmacodynamics. (author)

  3. Validation of HPLC-ESI-MS/MS Protocol to Analyze EtG in Hair for Assessment of Chronic Excessive Alcohol Use in Thailand in Conjunction with AUDIT.

    Science.gov (United States)

    Thananchai, Thiwaphorn; Junkuy, Anongphan; Kittirattanapaiboon, Phunnapa; Sribanditmongkol, Pongruk

    2016-06-01

    Hair analysis for chronic excessive alcohol (ethanol) use has focused on ethyl glucuronide (EtG), a minor metabolite of ethanol. Preferred methods have involved high-performance liquid chromatography (HPLC) combined with tandem mass spectrometry (MS/MS) in line with an electrospray ionization (ESI) source. EtG analysis in hair has not yet been introduced to Thailand To validate an in-house HPLC-ESI-MS/MS hair analysis protocol for EtG and to apply it to a field sample of alcohol drinkers to assess different risk levels of alcohol consumption as measured by the Alcohol Use Disorders Identification Test (AUDIT). Validation procedures followed guidelines of the US Food and Drug Administration, the European Medicines Agency, and the Scientific Working Group for Forensic Toxicology. One hundred twenty subjects reported consuming alcohol during a 3-month period prior to enrollment. After taking the Thai-language version of AUDIT, subjects were divided on the basis of test scores into low, medium, and high-risk groups for chronic excessive alcohol use. The protocol satisfied the international standards for selectivity, specificity, accuracy, precision, and calibration curve. There was no significant matrix effect. Limits of detection and quantification (LOD/LOQ) were set at 15 pg of EtG per mg of hair. The protocol was not able to detect EtG in low-risk subjects (n = 38). Detection rates for medium-risk (n = 42) and high-risk subjects (n = 40) were 14.3% and 85%, respectively. The median of EtG concentration between these two groups were significantly different. Sensitivity and specificity were both more than 90% when EtG concentrations of high-risk subjects were compared with the 30 pg/mg cutoff recommended by the Society of Hair Testing (SoHT) for diagnosing chronic excessive alcohol consumption, based on an average ethanol daily intake greater than 60 g. The in-house protocol for EtG analysis in hair was validated according to international standards. The protocol is a

  4. First characterisation of flavonoid- and diarylheptanoid-type antioxidant phenolics in Corylus maxima by HPLC-DAD-ESI-MS.

    Science.gov (United States)

    Riethmüller, Eszter; Tóth, Gergő; Alberti, Ágnes; Végh, Krisztina; Burlini, Ilaria; Könczöl, Árpád; Balogh, György Tibor; Kéry, Ágnes

    2015-03-25

    Corylus maxima Mill. (Betulaceae) leaves have been used in traditional medicine both internally and externally, nevertheless phytochemical exploration of the plant remains incomplete. In this study, the in vitro antioxidant activity and polyphenolic composition of the ethyl acetate and methanolic extracts of C. maxima leaves and bark are reported for the first time. The radical scavenging activities of the extracts were investigated by the ABTS and DPPH assays. All the extracts of C. maxima possessed notable antioxidant activity. By mean of a HPLC-DAD-ESI-TOF and a HPLC-DAD-ESI-MS/MS method, altogether twenty-two phenolics were tentatively characterised: one flavan derivative (1), seven flavonol derivatives (4, 6, 12, 13, 16, 20 and 21) and fourteen diarylheptanoids (2, 3, 5, 7-11, 14, 15, 17-19 and 22). The amount of the two main flavonoids - myricetin-3-O-rhamnoside (6) and quercetin-3-O-rhamnoside (13) - and two diarylheptanoids - oregonin (3) and hirsutenone (15) - in the extracts were determined by a validated HPLC-ESI-MS/MS method in multiple reaction monitoring (MRM) mode. Our results showed that C. maxima could be considered as a valuable source of pharmacologically important natural products that might contribute to the revaluation of the phytotherapeutical potential of the plant. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Determination of levodopa in human plasma by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS: application to a bioequivalence study

    Directory of Open Access Journals (Sweden)

    Heliana F. Martins

    2013-01-01

    Full Text Available A sensitive, accurate and simple method using HPLC-MS/MS was developed and validated for levodopa quantitation in human plasma. Analysis was achieved on a pursuit® C18 analytical column (5 µm; 150 x 4.6 mm i.d. using a mobile phase (methanol and water , 90:10, v/v containing formic acid 0.5% v/v, after extracting the samples using a simple protein plasma precipitation with perchloric acid. The developed method was validated in accordance with ANVISA guidelines and was successfully applied to a bioequivalence study in 60 healthy volunteers demonstrating the feasibility and reliability of the proposed method.

  6. Qualitative and Quantitative Analysis of Lignan Constituents in Caulis Trachelospermi by HPLC-QTOF-MS and HPLC-UV

    Directory of Open Access Journals (Sweden)

    Xiao-Ting Liu

    2015-05-01

    Full Text Available A high-performance liquid chromatography coupled with quadrupole tandem time-of-flight mass (HPLC-QTOF-MS and ultraviolet spectrometry (HPLC-UV was established for simultaneous qualitative and quantitative analysis of the major chemical constituents in Caulis Trachelospermi, respectively. The analysis was performed on an Agilent Zorbax Eclipse Plus C18 column (4.6 mm × 150 mm, 5 μm using a binary gradient system of water and methanol, with ultraviolet absorption at 230 nm. Based on high-resolution ESI-MS/MS fragmentation behaviors of the reference standards, the characteristic cleavage patterns of lignano-9, 9'-lactones and lignano-8'-hydroxy-9, 9'-lactones were obtained. The results demonstrated that the characteristic fragmentation patterns are valuable for identifying and differentiating lignano-9,9'-lactones and lignano-8'-hydroxy-9,9'-lactones. As such, a total of 25 compounds in Caulis Trachelospermi were unambiguously or tentatively identified via comparisons with reference standards or literature. In addition, 14 dibenzylbutyrolatone lignans were simultaneously quantified in Caulis Trachelospermi by HPLC-UV method. The method is suitable for the qualitative and quantitative analyses of dibenzylbutyrolatone lignans in Caulis Trachelospermi.

  7. An industry consensus study on an HPLC fluorescence method for the determination of (±)-catechin and (±)-epicatechin in cocoa and chocolate products.

    Science.gov (United States)

    Shumow, Laura; Bodor, Alison

    2011-07-05

    This manuscript describes the results of an HPLC study for the determination of the flavan-3-ol monomers, (±)-catechin and (±)-epicatechin, in cocoa and plain dark and milk chocolate products. The study was performed under the auspices of the National Confectioners Association (NCA) and involved the analysis of a series of samples by laboratories of five member companies using a common method. The method reported in this paper uses reversed phase HPLC with fluorescence detection to analyze (±)-epicatechin and (±)-catechin extracted with an acidic solvent from defatted cocoa and chocolate. In addition to a variety of cocoa and chocolate products, the sample set included a blind duplicate used to assess method reproducibility. All data were subjected to statistical analysis with outliers eliminated from the data set. The percent coefficient of variation (%CV) of the sample set ranged from approximately 7 to 15%. Further experimental details are described in the body of the manuscript and the results indicate the method is suitable for the determination of (±)-catechin and (±)-epicatechin in cocoa and chocolate products and represents the first collaborative study of this HPLC method for these compounds in these matrices.

  8. Simple and Selective HPLC-UV/Vis Bioanalytical Method to Determine Aluminum Phthalocyanine Chloride in Skin Permeation Studies

    Directory of Open Access Journals (Sweden)

    Thaiene Avila Reis

    2018-01-01

    Full Text Available Considering the feasibility of the aluminum phthalocyanine chloride (AlPcCl application in the topical photodynamic therapy of cutaneous tumors and the lack of HPLC methods capable of supporting skin permeation experiments using this compound, the aim of this study was to obtain a simple and selective chromatographic method for AlPcCl determination in skin matrices. A HPLC-UV/Vis method was developed using a normal-phase column operating at 30°C, an isocratic mobile phase of methanol : phosphoric acid (0.01 M at 1.5 mL/min, and detection at 670 nm. The method exhibited (i selectivity against various contaminants found in the different skin layers, (ii high drug extraction capacity from the hair follicle (>70% and remaining skin (>80%, and (iii low limits of detection and of quantification (0.03 and 0.09 μg/mL, resp.. The method was also linear in the range from 0.1 to 5.0 µg/mL (r = 0.9994 and demonstrated robustness with regard to experimental chromatographic parameters according to a factorial design. Lastly, the developed method was successfully tested in in vitro skin permeation studies of AlPcCl, proving its effectiveness in the development of pharmaceutical delivery systems containing this drug for topical photodynamic therapy of skin cancers.

  9. Validation of blood vitamin A concentrations in cattle: comparison of a new cow-side test (iCheck™ FLUORO) with high-performance liquid chromatography (HPLC).

    Science.gov (United States)

    Raila, Jens; Kawashima, Chiho; Sauerwein, Helga; Hülsmann, Nadine; Knorr, Christoph; Myamoto, Akio; Schweigert, Florian J

    2017-05-10

    Plasma concentration of retinol is an accepted indicator to assess the vitamin A (retinol) status in cattle. However, the determination of vitamin A requires a time consuming multi-step procedure, which needs specific equipment to perform extraction, centrifugation or saponification prior to high-performance liquid chromatography (HPLC). The concentrations of retinol in whole blood (n = 10), plasma (n = 132) and serum (n = 61) were measured by a new rapid cow-side test (iCheck™ FLUORO) and compared with those by HPLC in two independent laboratories in Germany (DE) and Japan (JP). Retinol concentrations in plasma ranged from 0.033 to 0.532 mg/L, and in serum from 0.043 to 0.360 mg/L (HPLC method). No significant differences in retinol levels were observed between the new rapid cow-side test and HPLC performed in different laboratories (HPLC vs. iCheck™ FLUORO: 0.320 ± 0.047 mg/L vs. 0.333 ± 0.044 mg/L, and 0.240 ± 0.096 mg/L vs. 0.241 ± 0.069 mg/L, lab DE and lab JP, respectively). A similar comparability was observed when whole blood was used (HPLC vs. iCheck™ FLUORO: 0.353 ± 0.084 mg/L vs. 0.341 ± 0.064 mg/L). Results showed a good agreement between both methods based on correlation coefficients of r 2  = 0.87 (P < 0.001) and Bland-Altman blots revealed no significant bias for all comparison. With the new rapid cow-side test (iCheck™ FLUORO) retinol concentrations in cattle can be reliably assessed within a few minutes and directly in the barn using even whole blood without the necessity of prior centrifugation. The ease of the application of the new rapid cow-side test and its portability can improve the diagnostic of vitamin A status and will help to control vitamin A supplementation in specific vitamin A feeding regimes such as used to optimize health status in calves or meat marbling in Japanese Black cattle.

  10. A validated stability indicating high-performance liquid chromatographic method for simultaneous estimation of cefuroxime sodium and sulbactam sodium in injection dosage form

    Directory of Open Access Journals (Sweden)

    Falguni M Patel

    2012-01-01

    Full Text Available Background: A fixed dose combination of cefuroxime sodium (β lactam antibiotic and sulbactam sodium (β Lactamase inhibitor is used in ratio of 2:1 as powder for injection for the treatment of resistant lower respiratory tract and other infections. Aims: A simple, precise, and accurate ion-pair reverse-phase high-performance liquid chromatography (RP-HPLC method was developed and validated for determination of cefuroxime Na(CEF and sulbactam Na(SUL in injection. Materials and Methods: Isocratic RP-HPLC separation was achieved on an ACE C 18 column (150×4.6 mm id, 5 μm particle size using the mobile phase 0.002 M tetrabutylammonium hydroxide sulfate (TBAH in 10 mm potassium di-hydrogen phosphate buffer-acetonitrile (86:14 v/v, pH 3.7 at a flow rate of 1.0 ml/min. Results and Conclusion: The retention time of sulbactam Na and cefuroxime Na were 3.2 min and 10.2 min, respectively. The ion-pairing reagent improved the retention of highly polar sulbactam Na on reverse-phase column. The detection was performed at 210 nm. The method was validated for linearity, precision, accuracy, robustness, solution stability, and specificity. The method was validated for linearity, precision, accuracy, robustness, solution stability, and specificity. The method was linear in the concentration range of 10-100 μg/ml for cefuroxime Na and 5-50 μg/ml for sulbactam Na, with a correlation coefficient of 0.9999 and 0.9998 for the respective drugs. The intraday precision was 0.13-0.21% and 0.48-0.65%, and the interday precision was 0.32-0.81% and 0.60-0.83% for cefuroxime Na and sulbactam Na, respectively. The accuracy (recovery was found to be in the range of 98.76-100.61% and 98.99-100.30% for cefuroxime Na and sulbactam Na, respectively. The drugs were found to degrade under hydrolytic and oxidative conditions. The drugs could be effectively separated from different degradation products, and hence the method can be used for stability analysis.

  11. Validation of high performance liquid chromatographic and spectrophotometric methods for the determination of the antiparkinson agent pramipexole dihydrochloride monohydrate in pharmaceutical products

    Directory of Open Access Journals (Sweden)

    Serpil Sevim

    2015-12-01

    Full Text Available abstract The antiparkinson agent pramipexole dihydrochloride monohydrate was quantified in pharmaceutical products by high performance liquid chromatography (HPLC and derivative spectrophotometry. The first method was based on HPLC using tamsulosin HCl as an internal standard. In this method, chromatographic separation was achieved using a LiChrospher 60 RP column at 25°C, with a flow rate of 1.0 mL/min at 263 nm. The eluent comprised 0.01 mol/L ammonium acetate (pH 4.4 and acetonitrile (35:65 by volume. The linearity range was found to be 10.0-30.0 µg/mL with a mean recovery of 100.5 ± 1.10. The limit of detection (8 ng/mL and limit of quantification (50 ng/mL were calculated. In the second method, the first derivative spectrophotometric technique for the determination of pramipexole dihydrochloride monohydrate was performed by measuring the amplitude at 249 and 280 nm. In the first derivative technique, the absorbance and concentration plot was rectilinear over the 5.0-35.0 µg/mL range with a lower detection limit of 1.5 ng/mL and quantification limit of 4.5 ng/mL. The typical excipients included in the pharmaceutical product do not interfere with the selectivity of either method. The developed methods were validated for robustness, selectivity, specificity, linearity, precision, and accuracy as per the ICH and FDA guidelines (ICH Q2B, 1996; FDA,2000. In conclusion, the developed methods were successful in determining the quantity of the antiparkinson agent pramipexole dihydrochloride monohydrate in pharmaceutical products. The RSD values for the pharmaceutical product used in this study were found to be 0.97% for the HPLC method and 0.00% for the first derivative spectrophotometric method.

  12. [HPLC fingerprint analysis of flavonoids of phyllanthi fructus from different habitats].

    Science.gov (United States)

    Wang, Fei; Wang, Shuai; Meng, Xian-sheng; Bao, Yong-rui; Zhu, Ying-huan

    2014-11-01

    To establish the HPLC fingerprint of flavonoids of Phyllanthi Fructus from different habitats. HPLC method was adopted. The flavonoids composition of Phyllanthi Fructus from 10 different habitats was determined on an Agilent C, chromatographic column with 0. 5% formic acid water (A)-acetonitrile (B) as the mobile phase in gradient elution under the wavelength of 254 nm. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus were established to evaluate the qualitiy of them. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus from 10 different habitats were established. 18 common peaks were found and the similarities of them were more than 0. 90 except the ones from Guangxi and Guangdong. The method is simple, accurate and repeatable. It can be used for research and quality control of the effective components in Phyllanthi Fructus.

  13. Development of an Ion-Pairing Reagent and HPLC-UV Method for the Detection and Quantification of Six Water-Soluble Vitamins in Animal Feed.

    Science.gov (United States)

    Kim, Ho Jin

    2016-01-01

    A novel and simple method for detecting six water-soluble vitamins in animal feed using high performance liquid chromatography equipped with a photodiode array detector (HPLC/PDA) and ion-pairing reagent was developed. The chromatographic peaks of the six water-soluble vitamins were successfully identified by comparing their retention times and UV spectra with reference standards. The mobile phase was composed of buffers A (5 mM PICB-6 in 0.1% CH3COOH) and B (5 mM PICB-6 in 65% methanol). All peaks were detected using a wavelength of 270 nm. Method validation was performed in terms of linearity, sensitivity, selectivity, accuracy, and precision. The limits of detection (LODs) for the instrument employed in these experiments ranged from 25 to 197 μg/kg, and the limits of quantification (LOQs) ranged from 84 to 658 μg/kg. Average recoveries of the six water-soluble vitamins ranged from 82.3% to 98.9%. Method replication resulted in intraday and interday peak area variation of water-soluble vitamins in animal feed.

  14. A validated high-performance liquid chromatography method with diode array detection for simultaneous determination of nine flavonoids in Senecio cannabifolius Less.

    Science.gov (United States)

    Niu, Tian-Zeng; Zhang, Yu-Wei; Bao, Yong-Li; Wu, Yin; Yu, Chun-Lei; Sun, Lu-Guo; Yi, Jing-Wen; Huang, Yan-Xin; Li, Yu-Xin

    2013-03-25

    A reversed phase high performance liquid chromatography method coupled with a diode array detector (HPLC-DAD) was developed for the first time for the simultaneous determination of 9 flavonoids in Senecio cannabifolius, a traditional Chinese medicinal herb. Agilent Zorbax SB-C18 column was used at room temperature and the mobile phase was a mixture of acetonitrile and 0.5% formic acid (v/v) in water in the gradient elution mode at a flow-rate of 1.0mlmin(-1), detected at 360nm. Validation of this method was performed to verify the linearity, precision, limits of detection and quantification, intra- and inter-day variabilities, reproducibility and recovery. The calibration curves showed good linearities (R(2)>0.9995) within the test ranges. The relative standard deviation (RSD) of the method was less than 3.0% for intra- and inter-day assays. The samples were stable for at least 96h, and the average recoveries were between 90.6% and 102.5%. High sensitivity was demonstrated with detection limits of 0.028-0.085μg/ml for flavonoids. The newly established HPLC method represents a powerful technique for the quality assurance of S. cannabifolius. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Simultaneous qualification and quantification of baccharane glycosides in Impatientis Semen by HPLC-ESI-MSD and HPLC-ELSD.

    Science.gov (United States)

    Li, Hui-Jun; Yu, Jun-Jie; Li, Ping

    2011-03-25

    This study presents a high performance liquid chromatography (HPLC) with electrospray ionization mass spectrometric detection (ESI-MSD) and evaporative light scattering detection (ELSD) method for the simultaneous qualification and quantification of eight major baccharane glycosides, namely hosenlosides A, B, C, F, G, K, L, and M in Impatientis Semen, a Chinese herbal medicine derived from the seeds of Impatiens balsamina L. In order to achieve optimum performance, several extraction parameters (including extraction solvent, extraction mode, extraction time) were optimized. The baccharane glycosides were separated on a Shim-pack CLC-ODS column with gradient elution of water and methanol. Temperature for the ELSD drift tube was set at 98°C and the nitrogen flow rate was 2.7l/min. The unambiguous identities of the analytes were realized by comparing retention times and mass data with those of reference compounds. The developed method was fully validated in terms of linearity, sensitivity, precision, repeatability, recovery as well as robustness, and subsequently applied to evaluate the quality of 14 batches of Impatientis Semen commercial samples from different collections. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Validation of a multi-analyte HPLC-DAD method for determination of uric acid, creatinine, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid and 2-methylhippuric acid in human urine.

    Science.gov (United States)

    Remane, Daniela; Grunwald, Soeren; Hoeke, Henrike; Mueller, Andrea; Roeder, Stefan; von Bergen, Martin; Wissenbach, Dirk K

    2015-08-15

    During the last decades exposure sciences and epidemiological studies attracts more attention to unravel the mechanisms for the development of chronic diseases. According to this an existing HPLC-DAD method for determination of creatinine in urine samples was expended for seven analytes and validated. Creatinine, uric acid, homovanillic acid, niacinamide, hippuric acid, indole-3-acetic acid, and 2-methylhippuric acid were separated by gradient elution (formate buffer/methanol) using an Eclipse Plus C18 Rapid Resolution column (4.6mm×100mm). No interfering signals were detected in mobile phase. After injection of blank urine samples signals for the endogenous compounds but no interferences were detected. All analytes were linear in the selected calibration range and a non weighted calibration model was chosen. Bias, intra-day and inter-day precision for all analytes were below 20% for quality control (QC) low and below 10% for QC medium and high. The limits of quantification in mobile phase were in line with reported reference values but had to be adjusted in urine for homovanillic acid (45mg/L), niacinamide 58.5(mg/L), and indole-3-acetic acid (63mg/L). Comparison of creatinine data obtained by the existing method with those of the developed method showing differences from -120mg/L to +110mg/L with a mean of differences of 29.0mg/L for 50 authentic urine samples. Analyzing 50 authentic urine samples, uric acid, creatinine, hippuric acid, and 2-methylhippuric acid were detected in (nearly) all samples. However, homovanillic acid was detected in 40%, niacinamide in 4% and indole-3-acetic acid was never detected within the selected samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Fingerprinting and validation of a LC-DAD method for the analysis of biflavanones in Garcinia kola-based antimalarial improved traditional medicines.

    Science.gov (United States)

    Tshibangu, P Tshisekedi; Kapepula, P Mutwale; Kapinga, M J Kabongo; Lupona, H Kabika; Ngombe, N Kabamba; Kalenda, Dibungi T; Jansen, O; Wauters, J N; Tits, M; Angenot, L; Rozet, E; Hubert, Ph; Marini, R D; Frédérich, M

    2016-09-05

    African populations use traditional medicines in their initial attempt to treat a range of diseases. Nevertheless, accurate knowledge of the composition of these drugs remains a challenge in terms of ensuring the health of population and in order to advance towards improved traditional medicines (ITMs). In this paper chromatographic methods were developed for qualitative and quantitative analyses of a per os antimalarial ITM containing Garcinia kola. The identified analytical markers were used to establish TLC and HPLC fingerprints. G. kola seeds were analysed by HPLC to confirm the identity of the extract used by the Congolese manufacturer in the ITM. The main compounds (GB1, GB2, GB-1a and Kolaflavanone) were isolated by preparative TLC and identified by UPLC-MS and NMR. For the quantification of the major compound GB1, a simple and rapid experimental design was applied to develop an LC method, and then its validation was demonstrated using the total error strategy with the accuracy profile as a decision tool. The accurate results were observed within 0.14-0.45mg/mL range of GB1 expressed as naringenin. The extracts used in several batches of the analysed oral solutions contained GB1 (expressed as naringenin) within 2.04-2.43%. Both the fingerprints and the validated LC-DAD were found suitable for the quality control of G. kola-based raw material and finished products, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Determination of very low levels of 5-(hydroxymethyl)-2-furaldehyde (HMF) in natural honey: comparison between the HPLC technique and the spectrophotometric white method.

    Science.gov (United States)

    Truzzi, Cristina; Annibaldi, Anna; Illuminati, Silvia; Finale, Carolina; Rossetti, Monica; Scarponi, Giuseppe

    2012-07-01

    In this work we compared 2 official methods for the determination of HMF in honey, the spectrophotometric White method and the HPLC method (International Honey Commission) for the determination of HMF in unifloral honey and honeydew samples with a very low HMF content (5 mg/kg, the molar extinction coefficient is 15369, lower than the literature value of 16830, and should be used for HMF determination. For samples with HMF content in the range 1-4 mg/kg the accuracy of the 2 methods is comparable both for unifloral and honeydew samples, whereas as regards precision, the HPLC method gives better results (3.5% compared with 6.4% for the White method). So, in general, the HPLC method seems to be more appropriate for the determination of HMF in honey in the range 1-4 mg/kg thanks to its greater precision, but for samples with a HMF content of less than 1 mg/kg the analyses are inaccurate for both methods. This work can help governmental and private laboratories that perform food analyses to choose the best method for the determination of HMF at very low levels in unifloral honey and honeydew samples. © 2012 Institute of Food Technologists®

  19. Simultaneous HPLC Determination of Chlordiazepoxide and Mebeverine HCl in the Presence of Their Degradation Products and Impurities

    Directory of Open Access Journals (Sweden)

    Rania N. El-Shaheny

    2015-01-01

    Full Text Available A simple, rapid, and sensitive RP-HPLC method was developed and validated for the simultaneous determination of chlordiazepoxide (CDO and mebeverine HCl (MBV in the presence of CDO impurity (2-amino-5-chlorobenzophenone, ACB and MBV degradation product (veratric acid, VER. Separation was achieved within 9 min on a BDS Hypersil phenyl column (4.5 mm × 250 mm, 5 µm particle size using a mobile phase consisting of acetonitrile: 0.1 M potassium dihydrogen phosphate: triethylamine (35 : 65 : 0.2, v/v/v in an isocratic mode at a flow rate of 1 mL/min. The pH of the mobile phase was adjusted to 4.5 with orthophosphoric acid and UV detection was set at 260 nm. A complete validation procedure was conducted. The proposed method exhibited excellent linearity over the concentration ranges of 1.0–100.0, 10.0–200.0, 2.0–40.0, and 2.0–40.0 µg/mL for CDO, MBV, VER, and ACB, respectively. The proposed method was applied for the simultaneous determination of CDO and MBV in their coformulated tablets with mean percentage recoveries of 99.75 ± 0.62 and 98.61 ± 0.38, respectively. The results of the proposed method were favorably compared with those of a comparison HPLC method using Student t-test and the variance ratio F-test. The chemical structure of MBV degradation product was ascertained by mass spectrometry and IR studies.

  20. Optimized Analytical Method to Determine Gallic and Picric Acids in Pyrotechnic Samples by Using HPLC/UV (Reverse Phase)

    International Nuclear Information System (INIS)

    Garcia Alonso, S.; Perez Pastor, R. M.

    2013-01-01

    A study on the optimization and development of a chromatographic method for the determination of gallic and picric acids in pyrotechnic samples is presented. In order to achieve this, both analytical conditions by HPLC with diode detection and extraction step of a selected sample were studied. (Author)

  1. [HPLC characteristic fingerprints of sedi linearis herba and sedi herba].

    Science.gov (United States)

    Lu, Lan-Qing; Mei, Qing; Wan, Ding-Rong; Yang, Xin-Zhou; Qiao, Shu; Zhao, Yu-Dan

    2014-04-01

    To study HPLC characteristic fingerprint of Sedum lineare from different harvest periods, and to compare with its related species Sedum sarmentosum. The HPLC fingerprints of Sedum lineare from different collecting periods were established and compared with Sedum sarmentosum by the same detection method. Hyperin, isoquercitrin and astragaloside were identified from the HPLC fingerprint of Sedum lineare. The fingerprint of Sedum lineare growing in the same area but different environment were basically identical; while there were remarkable differences of Sedum lineare growing in the same place but from different harvest periods, with the area of most common peaks changing from little to great, and slightly different peak number. The HPLC fingerprint of the two Sedum species had four common peaks, but could be distinguished from each other. The optimal harvest period of these two species should be full-bloom stage. The established method can provide reference for identification and quality analysis of Sedum lineare.

  2. A clinical assay for the measurement of milrinone in plasma by HPLC mass spectrometry.

    Science.gov (United States)

    Chihoho, B; Sage, A B; Smolenski, R T; Vazir, A; Rose, M L; Banner, N R; Leaver, N V

    2012-05-01

    Milrinone is a bipyridine phosphodiesterase inhibitor with positive inotropic and vasodilatory effects. As interest in longer term use of intravenous therapy increases, it becomes essential to monitor its plasma concentration owing to a narrow therapeutic range, an increased half-life in renal failure and toxicity associated with high levels. A high-performance liquid chromatography (HPLC) method with mass (MS) detection using a triple quadrupole mass spectrometer is presented. The method was compared with the UV/HPLC method and validated according to current international guidelines. Coefficients of variation of less than 7.5% were obtained across the therapeutic range and 18.3% at 2.4 ng/mL, the lower limit of quantitation. Plasma from 13 cardiac surgery patients receiving standard intravenous doses of milrinone were measured. Eight patients achieved therapeutic milrinone levels within 3-4 h post start of infusion, one was borderline sub-therapeutic and four patients achieved levels that were above the upper limit of the therapeutic range and potentially toxic. This method offers high sensitivity, is rapid, easy to use and requires minimal amount of sample. We believe this method could become the reference procedure for clinical monitoring of milrinone and help to improve the safety of the use of this drug in patients with cardiac failure. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Development and Validation of High Performance Liquid Chromatographic Method for Determination of Lamivudine from Pharmaceutical Preparation

    Directory of Open Access Journals (Sweden)

    S. K. Patro

    2010-01-01

    Full Text Available A new, simple, specific, accurate and precise RP-HPLC method was developed for determination of lamivudine in pure and tablet formulations. A Thermo BDS C18 column in isocratic mode, with a mobile phase consisting of 0.01 M ammonium dihydrogen orthophosphate buffer adjusted to pH 2.48 by using formic acid and methanol in the ratio of 50:50 was used. The flow rate was set at 0.6 mL/min and UV detection was carried out at 264 nm. The retention time of lamivudine and nevirapine were 2.825 min and 4.958 min respectively. The method was validated for linearity, precision, robustness and recovery. Linearity for lamivudine was found in the range of 50-175 μg/mL. Hence, it can be applied for routine quality control of lamivudine in bulk and pharmaceutical formulations.

  4. Determination of Amphetamine, Amfepramone and Fenproporex in Urine Samples by HPLC-DAD: Application to a Population of Brazilian Truck Drivers

    OpenAIRE

    Takitane, Juliana; Almeida, Rafael M.; Oliveira, Tiago F.; Prado, Natanael V.; Muñoz, Daniel R.; Leyton, Vilma; Yonamine, Mauricio

    2016-01-01

    Commercially available immunoassay tests are designed to detect the presence of amphetamine/methamphetamine or methylenodioxyamphetamines. However, it is known that Brazilian truck drivers also report the use of other illicit amphetamines, such as amfepramone and fenproporex. Thus, a method was developed and validated in order to quantify amphetamine-type stimulants (amphetamine, fenproporex and amfepramone) in urine by high performance liquid chromatography with diode array detection (HPLC-D...

  5. Simultaneous Estimation and Validation of Atorvastatin Calcium and Aspirin in Combined Capsule Dosage Form by RP HPLC Method

    Directory of Open Access Journals (Sweden)

    B. V. Suma

    2012-01-01

    Full Text Available A new simple, specific, precise and accurate revere phase liquid chromatography method has been developed for estimation of atorvastatin calcium (AST and ASPIRIN (ASP simultaneously in a combined capsule dosage forms. The chromatographic separation was achieved on a 5 – micron C 18 column (250x 4.6mm using a mobile phase consisting of a mixture of Acetonitrile: Ammonium Acetate buffer 0.02M (68:32 pH 4.5. The flow rate was maintained at 0.8 ml/min. The detection of the constituents was done using UV detector at 245 nm for AST and ASP. The retention time of AST and ASP were found be 4.5915 ± 0.0031 min and 3.282 ±0.0024 min respectively. The developed method was validated for accuracy, linearity, precision, limit of detection (LOD and limit of quantification (LOQ and robustness as per the ICH guidelines.

  6. Selenium speciation analysis of Misgurnus anguillicaudatus selenoprotein by HPLC-ICP-MS and HPLC-ESI-MS/MS

    Science.gov (United States)

    Analytical methods for selenium (Se) speciation were developed using high performance liquid chromatography (HPLC) coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionization tandem mass spectrometry (ESI-MS/MS). Separations of selenomethionine (Se-Met) and sel...

  7. Reverse-phase HPLC analysis of human alpha crystallin.

    Science.gov (United States)

    Swamy, M S; Abraham, E C

    1991-03-01

    A rapid and highly sensitive reverse-phase HPLC (RP-HPLC) method was used to separate crystallin subunits from human alpha crystallin. Three distinct peaks were separated; by electrophoretic and immunological analyses the first and second peaks were identified as alpha B and alpha A respectively. On the other hand, peak 3 appeared to be a modified form of alpha crystallin. The ratio of alpha A and alpha B proteins was 3:1 in 1 day old lenses which gradually changed to 2:1 in 17 year old lenses and to 1:1 in the 50 and 82 year old whole lenses and 82 year old lens cortex, with a concomitant increase in the modified alpha, suggesting that alpha A subunits are relatively more involved in aggregation. Analysis of the 82 year old lens nucleus also supported this conclusion. The RP-HPLC analysis of the HMW aggregate fraction showed substantial enrichment of the modified alpha. The alpha A and alpha B subunits independently reassociated to form polymeric alpha crystallin whereas the modified alpha reassociated to form HMW aggregates as shown by molecular sieve HPLC. Hence it appears that the HMW aggregate peak was constituted by modified alpha crystallin. Only in the peak 3 material the 280 nm absorbance was about 2-fold higher than what was expected from the actual protein content. The data suggest that the changes induced by post-translational modifications may have some role in the formation of modified alpha. The present RP-HPLC method is useful in separating these modified alpha from the unmodified alpha A and alpha B subunits.

  8. HPLC method for rapidly following biodiesel fuel transesterification reaction progress using a core-shell column.

    Science.gov (United States)

    Allen, Samuel J; Ott, Lisa S

    2012-07-01

    There are a wide and growing variety of feedstocks for biodiesel fuel. Most commonly, these feedstocks contain triglycerides which are transesterified into the fatty acid alkyl esters (FAAEs) which comprise biodiesel fuel. While the tranesterification reaction itself is simple, monitoring the reaction progress and reaction products is not. Gas chromatography-mass spectrometry is useful for assessing the FAAE products, but does not directly address either the tri-, di-, or monoglycerides present from incomplete transesterification or the free fatty acids which may also be present. Analysis of the biodiesel reaction mixture is complicated by the solubility and physical property differences among the components of the tranesterification reaction mixture. In this contribution, we present a simple, rapid HPLC method which allows for monitoring all of the main components in a biodiesel fuel transesterification reaction, with specific emphasis on the ability to monitor the reaction as a function of time. The utilization of a relatively new, core-shell stationary phase for the HPLC column allows for efficient separation of peaks with short elution times, saving both time and solvent.

  9. A modified HPLC method improves the simultaneous determination of plasma kynurenine and tryptophan concentrations in patients following maintenance hemodialysis

    Science.gov (United States)

    XIAO, CHENGGEN; CHEN, YUANHAN; LIANG, XINLING; XIE, ZHEN; ZHANG, MIN; LI, RUIZHAO; LI, ZHILIAN; FU, XIA; YU, XIYONG; SHI, WEI

    2014-01-01

    The ratio between plasma kynurenine (Kyn) and tryptophan (Trp) serves as a marker of indoleamine 2,3-dioxygenase, a critical immunomodulatory molecule. Simultaneous detection of the two markers may be performed using high-pressure liquid chromatography (HPLC). However, for uremic patients, the conventional detection method may be affected by a range of accumulated toxins. The current study aimed to establish a method for the simultaneous measurement of Kyn and Trp in patients following maintenance hemodialysis via HPLC-ultraviolet detection. The procedure involved the use of a SinoChrom ODS-BP C18 column (4.6×150 mm; inner diameter, 4.5 μm) and a mobile phase of 15 mmol/l sodium acetate acetic acid solution (containing 5% acetonitrile, pH 4.8). The modified method was verified using plasma samples from 10 healthy controls and 91 maintenance hemodialysis patients. The results demonstrated that the modified method was successful in simultaneously detecting the concentrations of Trp and Kyn in the healthy controls and maintenance hemodialysis patients. The method is simple, fast, accurate and suitable for clinical and research purposes in maintenance hemodialysis patients. PMID:24669249

  10. Comparison of a point-of-care analyser for the determination of HbA1c with HPLC method

    OpenAIRE

    Grant, D.A.; Dunseath, G.J.; Churm, R.; Luzio, S.D.

    2017-01-01

    Aims: As the use of Point of Care Testing (POCT) devices for measurement of glycated haemoglobin (HbA1c) increases, it is imperative to determine how their performance compares to laboratory methods. This study compared the performance of the automated Quo-Test POCT device (EKF Diagnostics), which uses boronate fluorescence quenching technology, with a laboratory based High Performance Liquid Chromatography (HPLC) method (Biorad D10) for measurement of HbA1c. Methods: Whole blood EDTA samples...

  11. SIMULTANEOUS ESTIMATION OF MOXIFLOXACIN HYDROCHLORIDE AND DEXAMETHASONE SODIUM PHOSPHATE IN BULK AND IN OPHTHALMIC SOLUTION BY RP- HPLC

    OpenAIRE

    DHUMAL, D. M; SHIRKHEDKAR, A. A; NERKAR, P. P; SURANA, S. J

    2012-01-01

    A new simple, precise, accurate and selective RP-HPLC method has been developed and validated for simultaneous estimation of Moxifloxacin Hydrochloride (MOX) and Dexamethasone Sodium Phosphate (DSP) in Ophthalmic Solution. The method was carried out on a Qualisil RP C-8 (250 mm x 4.6 mm, 5 µm) column with a mobile phase consisting of Methanol: Water (75:25 v/v) pH adjusted to 3.0 with ortho-phosphoric acid of aqueous phase and flow rate of 1.0 mL min¹. Detection was carried out at 240 nm. The...

  12. Development and validation of a high-performance liquid chromatography method for the quantification of talazoparib in rat plasma: Application to plasma protein binding studies.

    Science.gov (United States)

    Hidau, Mahendra Kumar; Kolluru, Srikanth; Palakurthi, Srinath

    2018-02-01

    A sensitive and selective RP-HPLC method has been developed and validated for the quantification of a highly potent poly ADP ribose polymerase inhibitor talazoparib (TZP) in rat plasma. Chromatographic separation was performed with isocratic elution method. Absorbance for TZP was measured with a UV detector (SPD-20A UV-vis) at a λ max of 227 nm. Protein precipitation was used to extract the drug from plasma samples using methanol-acetonitrile (65:35) as the precipitating solvent. The method proved to be sensitive and reproducible over a 100-2000 ng/mL linearity range with a lower limit of quantification (LLQC) of 100 ng/mL. TZP recovery was found to be >85%. Following analytical method development and validation, it was successfully employed to determine the plasma protein binding of TZP. TZP has a high level of protein binding in rat plasma (95.76 ± 0.38%) as determined by dialysis method. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Validação de metodologia analítica por cromatografia líquida para doseamento e estudo da estabilidade de pantoprazol sódico Validation of analytical methodology by hplc for quantification and stability evaluation of sodium pantoprazole

    Directory of Open Access Journals (Sweden)

    Renata Platcheck Raffin

    2007-08-01

    Full Text Available Pantoprazole is a proton pump inhibitor used in the treatment of digestive ulcers, gastro-esophageal reflux disease and in the eradication of Helicobacter pylori. In this work, an analytical method was developed and validated for the quantification of sodium pantoprazole by HPLC. The method was specific, linear, precise and exact. In order to verify the stability of pantoprazole during dissolution assays, pantoprazole solution in phosphate buffer pH 7.4 was kept at room temperature and protected from light for 22 days. Pantoprazole presented less than 5% of degradation in 6 hours and the half live of the degradation was 124 h.

  14. Identification and quantification of flavonoids and chromes in Baeckea frutescens by using HPLC coupled with diode-array detection and quadruple time-of-flight mass spectrometry.

    Science.gov (United States)

    Jia, Bei-Xi; Huangfu, Qian-Qian; Ren, Feng-Xiao; Jia, Lu; Zhang, Yan-Bing; Liu, Hong-Min; Yang, Jie; Wang, Qiang

    2015-01-01

    This article marks the first report on high-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD) and quadruple time-of-flight mass spectrometry (Q-TOF/MS) for the identification and quantification of main bioactive constituents in Baeckea frutescens. In total, 24 compounds were identified or tentatively characterised based on their retention behaviours, UV profiles and MS fragment information. Furthermore, a validated method with good linearity, sensitivity, precision, stability, repeatability and accuracy was successfully applied for simultaneous determination of five flavonoids and one chromone in different plant parts of B. frutescens collected at different harvest times, and their dynamic contents revealed the appropriate harvest times. The established HPLC-DAD-Q-TOF/MS using multi-bioactive markers was proved to be a validated strategy for the quality evaluation on both raw materials and related products of B. frutescens.

  15. The use of experimental design in the development of an HPLC-ECD method for the analysis of captopril.

    Science.gov (United States)

    Khamanga, Sandile M; Walker, Roderick B

    2011-01-15

    An accurate, sensitive and specific high performance liquid chromatography-electrochemical detection (HPLC-ECD) method that was developed and validated for captopril (CPT) is presented. Separation was achieved using a Phenomenex(®) Luna 5 μm (C(18)) column and a mobile phase comprised of phosphate buffer (adjusted to pH 3.0): acetonitrile in a ratio of 70:30 (v/v). Detection was accomplished using a full scan multi channel ESA Coulometric detector in the "oxidative-screen" mode with the upstream electrode (E(1)) set at +600 mV and the downstream (analytical) electrode (E(2)) set at +950 mV, while the potential of the guard cell was maintained at +1050 mV. The detector gain was set at 300. Experimental design using central composite design (CCD) was used to facilitate method development. Mobile phase pH, molarity and concentration of acetonitrile (ACN) were considered the critical factors to be studied to establish the retention time of CPT and cyclizine (CYC) that was used as the internal standard. Twenty experiments including centre points were undertaken and a quadratic model was derived for the retention time for CPT using the experimental data. The method was validated for linearity, accuracy, precision, limits of quantitation and detection, as per the ICH guidelines. The system was found to produce sharp and well-resolved peaks for CPT and CYC with retention times of 3.08 and 7.56 min, respectively. Linear regression analysis for the calibration curve showed a good linear relationship with a regression coefficient of 0.978 in the concentration range of 2-70 μg/mL. The linear regression equation was y=0.0131x+0.0275. The limits of detection (LOQ) and quantitation (LOD) were found to be 2.27 and 0.6 μg/mL, respectively. The method was used to analyze CPT in tablets. The wide range for linearity, accuracy, sensitivity, short retention time and composition of the mobile phase indicated that this method is better for the quantification of CPT than the

  16. Micellar HPLC and derivative spectrophotometric methods for the simultaneous determination of fluconazole and tinidazole in pharmaceuticals and biological fluids.

    Science.gov (United States)

    Belal, F; Sharaf El-Din, M K; Eid, M I; El-Gamal, R M

    2014-04-01

    Micellar high-performance liquid chromatography (HPLC) and first-derivative ultraviolet spectrophotometry were used to simultaneously determine fluconazole (FLZ) and tinidazole (TNZ) in combined pharmaceutical dosage forms. The derivative procedure is based on the linear relationship between the drug concentration and the first derivative amplitudes at 220 and 288 nm for FLZ and TNZ, respectively. The calibration graphs were linear in the range of 1.5-9.0 µg/mL for FLZ and 10.0-60.0 µg/mL for TNZ. Furthermore, an HPLC procedure with ultraviolet detection at 210 nm was developed. For the HPLC procedure, good chromatographic separation was achieved using an ODS C18 column (250 × 4.6 mm i.d.). The mobile phase containing 0.15M sodium dodecyl sulphate, 0.3% triethylamine and 12% n-propanol in 0.02M orthophosphoric acid at pH 5.5 was pumped at a flow rate of 1 mL/min. Indapamide was used as an internal standard. The method showed good linearity over the concentration ranges of 1.5-30.0 and 10.0-200.0 µg/mL, with limits of detection of 0.36 and 2.70 µg/mL and limits of quantification of 1.1 and 8.2 µg/mL for FLZ and TNZ, respectively. The suggested methods were successfully applied for the simultaneous analysis of the drugs in their laboratory prepared mixture, co-formulated tablet and single dosage forms. Moreover the second method was also extended to the determination of the drugs in biological fluids.

  17. Validating a High Performance Liquid Chromatography-Ion Chromatography (HPLC-IC) Method with Conductivity Detection After Chemical Suppression for Water Fluoride Estimation.

    Science.gov (United States)

    Bondu, Joseph Dian; Selvakumar, R; Fleming, Jude Joseph

    2018-01-01

    A variety of methods, including the Ion Selective Electrode (ISE), have been used for estimation of fluoride levels in drinking water. But as these methods suffer many drawbacks, the newer method of IC has replaced many of these methods. The study aimed at (1) validating IC for estimation of fluoride levels in drinking water and (2) to assess drinking water fluoride levels of villages in and around Vellore district using IC. Forty nine paired drinking water samples were measured using ISE and IC method (Metrohm). Water samples from 165 randomly selected villages in and around Vellore district were collected for fluoride estimation over 1 year. Standardization of IC method showed good within run precision, linearity and coefficient of variance with correlation coefficient R 2  = 0.998. The limit of detection was 0.027 ppm and limit of quantification was 0.083 ppm. Among 165 villages, 46.1% of the villages recorded water fluoride levels >1.00 ppm from which 19.4% had levels ranging from 1 to 1.5 ppm, 10.9% had recorded levels 1.5-2 ppm and about 12.7% had levels of 2.0-3.0 ppm. Three percent of villages had more than 3.0 ppm fluoride in the water tested. Most (44.42%) of these villages belonged to Jolarpet taluk with moderate to high (0.86-3.56 ppm) water fluoride levels. Ion Chromatography method has been validated and is therefore a reliable method in assessment of fluoride levels in the drinking water. While the residents of Jolarpet taluk (Vellore distict) are found to be at a high risk of developing dental and skeletal fluorosis.

  18. Measurements of urinary kinins by HPLC-radioimmunoassay

    International Nuclear Information System (INIS)

    Fejes-Toth, G.; Naray-Fejes-Toth, A.; Froelich, J.C.

    1984-01-01

    In this paper the authors describe a method for the individual determination of urinary kinins. Extraction from the urine is performed on an Amberlite CG-50 column and kinins are eluted with formic acid. The samples are further purified and kinins are separated by reversed phase HPLC. Bradykinin and lysylbradykinin are quantified by a sensitive radioimmunoassay capable of detecting 0.1 fmol of either peptide. Procedural losses are monitored by measuring the recovery of [ 3 H]bradykinin and [ 3 H]lysylbradykinin. Simple methods for labeling of bradykinin and lysylbradykinin with tritium are also presented. Recoveries of [ 3 H]bradykinin and [ 3 H]lysylbradykinin from biological material ranged between 77 and 91%. The combination of HPLC with radioimmunoassay makes it possible to determine kinin concentrations of biological samples with a higher sensitivity and greater specificity than previous methods. (Auth.)

  19. A Stability-Indicating HPLC-DAD Method for Determination of Stiripentol: Development, Validation, Kinetics, Structure Elucidation and Application to Commercial Dosage Form

    Directory of Open Access Journals (Sweden)

    Hany W. Darwish

    2014-01-01

    Full Text Available A rapid, simple, sensitive, and accurate isocratic reversed-phase stability-indicating high performance liquid chromatography method has been developed and validated for the determination of stiripentol and its degradation product in its bulk form and pharmaceutical dosage form. Chromatographic separation was achieved on a Symmetry C18 column and quantification was achieved using photodiode array detector (DAD. The method was validated in accordance with the ICH requirements showing specificity, linearity (r2=0.9996, range of 1–25 μg/mL, precision (relative standard deviation lower than 2%, accuracy (mean recovery 100.08±1.73, limits of detection and quantitation (LOD = 0.024 and LOQ = 0.081 μg/mL, and robustness. Stiripentol was subjected to various stress conditions and it has shown marked stability under alkaline hydrolytic stress conditions, thermal, oxidative, and photolytic conditions. Stiripentol degraded only under acidic conditions, forming a single degradation product which was well resolved from the pure drug with significantly different retention time values. This degradation product was characterized by 1H-NMR and 13C-NMR spectroscopy as well as ion trap mass spectrometry. The results demonstrated that the method would have a great value when applied in quality control and stability studies for stiripentol.

  20. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  1. Separation and Simultaneous Determination of 14 Fungicides with the Combination of Multi-Analyte Methods and HPLC Detection

    Energy Technology Data Exchange (ETDEWEB)

    Canping, Pan [Department of Applied Chemistry, China Agricultural University, Beijing (China)

    2009-07-15

    The separation and simultaneous HPLC-MS determination for a series of fungicide products is reported. Multi-analyte methods were applied on a Chromolith RP-18e monolithic column having low resistance and enabling high flow rates and short analysis time at very good separation power. Details and analytical conditions are described with chromatograms illustrating the results and work done. (author)

  2. Relative bioavailability studies on a locally manufactured aspirin tablets using UV spectrophotometry and HPLC

    International Nuclear Information System (INIS)

    Kwadzo, Ameko David

    2005-11-01

    Modern trends in drug analysis require use of less time consuming, efficient, cost effective, fast, reproducible, simple and convenient methods. Two analytical methods were employed for the determination, the UV spectrophotometry and the HPLC. Aspirin, which is rapidly deacetylated to salicylic acid after absorption into the plasma, is excreted in the urine. In determining the salicylic acid concentration in the urine, the absorbance was quantitated by a spectrometer at a wavelength of 540nm. Aspirin formed an amber coloured complex with ferric ions (Trinder’s reagent). The complex, which formed instantaneously at room temperature, was stable. The solution of the complex obeyed Beer’s law at 540nm, the wavelength of maximum absorption of radiation (λmax). Phenol—induced absorbance is quenched by acidifying the reaction mixture with phosphoric acid. An HPLC analytical method was used in determining the free salicylate excreted in the urine. The mobile phase employed is a validated method from the USP- XXII (1990) which consists of water, methanol and glacial acetic acid in the ratio 69: 28: 3 respectively. The chromatographic conditions involved a flow rate of 1.0ml/rnin, wavelength of maximum absorption of 236nrn, stationary phase Spherisorb S5 ODS 1 phase sep column with standard dimensions of 25.0 cm length and 4.6cm diameter and chart recorder speed of 5mm/min. The quality of the reference and the test tablets were assessed by a number of standard tests, which include uniformity of weight, friability, hardness and dissolution that fall within the BP 2000 specification. The observation from the study reveals that the relative bioavailability of aspirin (w.r.t. salicylic acid) were 103.39% and 94.93% for HPLC and UV respectively. The mean cumulative percentage of the drug excreted in both cases were ii .05% and 10.69% for test and reference respectively for HPLC and 76.45% and 80.53% for test and reference respectively for UV analysis. The cumulative amount

  3. Curcuminoid content of Curcuma longa L. and Curcuma xanthorrhiza rhizome based on drying method with NMR and HPLC-UVD

    Science.gov (United States)

    Hadi, S.; Artanti, A. N.; Rinanto, Y.; Wahyuni, D. S. C.

    2018-04-01

    Curcuminoid, consisting of curcumin, demethoxycurcumin and bis demethoxycurcumin, is the major compound in Curcuma longa L. and Curcuma xanthorrhiza rhizome. It has been known to have a potent antioxidants, anticancer, antibacteria activity. Those rhizomes needs to be dried beforehand which influenced the active compounds concentration. The present work was conducted to assess the curcuminoid content of C. longa L. and C. xanthorrhiza based on drying method with Nuclear Magnetic Resonance (NMR) and High Pressure Liquid Chromatography (HPLC)-UVD. Samples were collected and dried using freeze-drying and oven method. The latter is the common method applied in most drying method at herbal medicine preparation procedure. All samples were extracted using 96% ethanol and analyzed using NMR and HPLC-UVD. Curcuminoid as a bioactive compound in the sample exhibited no significant difference and weak significant difference in C. xanthorrhiza and C. longa L., respectively. HLPC-UVD as a reliable analytical method for the quantification is subsequently used to confirm of the data obtained by NMR. It resulted that curcuminoid content showed no significant difference in both samples. This replied that curcuminoids content in both samples were stable into heating process. These results are useful information for simplicia standardization method in pharmaceutical products regarding to preparation procedure.

  4. An optimized method for automated analysis of algal pigments by HPLC

    NARCIS (Netherlands)

    van Leeuwe, M. A.; Villerius, L. A.; Roggeveld, J.; Visser, R. J. W.; Stefels, J.

    2006-01-01

    A recent development in algal pigment analysis by high-performance liquid chromatography (HPLC) is the application of automation. An optimization of a complete sampling and analysis protocol applied specifically in automation has not yet been performed. In this paper we show that automation can only

  5. High-performance liquid chromatography method for the determination of hydrogen peroxide present or released in teeth bleaching kits and hair cosmetic products.

    Science.gov (United States)

    Gimeno, Pascal; Bousquet, Claudine; Lassu, Nelly; Maggio, Annie-Françoise; Civade, Corinne; Brenier, Charlotte; Lempereur, Laurent

    2015-03-25

    This manuscript presents an HPLC/UV method for the determination of hydrogen peroxide present or released in teeth bleaching products and hair products. The method is based on an oxidation of triphenylphosphine into triphenylphosphine oxide by hydrogen peroxide. Triphenylphosphine oxide formed is quantified by HPLC/UV. Validation data were obtained using the ISO 12787 standard approach, particularly adapted when it is not possible to make reconstituted sample matrices. For comparative purpose, hydrogen peroxide was also determined using ceric sulfate titrimetry for both types of products. For hair products, a cross validation of both ceric titrimetric method and HPLC/UV method using the cosmetic 82/434/EEC directive (official iodometric titration method) was performed. Results obtained for 6 commercialized teeth whitening products and 5 hair products point out similar hydrogen peroxide contain using either the HPLC/UV method or ceric sulfate titrimetric method. For hair products, results were similar to the hydrogen peroxide content using the cosmetic 82/434/EEC directive method and for the HPLC/UV method, mean recoveries obtained on spiked samples, using the ISO 12787 standard, ranges from 100% to 110% with a RSDhydrogen peroxide contents higher than the regulated limit. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Validation of an analytical method applicable to study of 1 mg/mL oral Risperidone solution stability

    International Nuclear Information System (INIS)

    Abreu Alvarez, Maikel; Garcia Penna, Caridad Margarita; Martinez Miranda, Lissette

    2010-01-01

    A validated analytical method by high-performance liquid chromatography (HPLC) was applicable to study of 1 mg/mL Risperidone oral solution stability. The above method was linear, accurate, specific and exact. A stability study of the 1 mg/mL Risperidone oral solution was developed determining its expiry date. The shelf life study was conducted for 24 months at room temperature; whereas the accelerated stability study was conducted with product under influence of humidity and temperature; analysis was made during 3 months. Formula fulfilled the quality specifications described in Pharmacopeia. The results of stability according to shelf life after 24 months showed that the product maintains the parameters determining its quality during this time and in accelerated studies there was not significant degradation (p> 0.05) in the product. Under mentioned conditions expiry date was of 2 years

  7. Comparative studies of HPLC-fluorometry and LC/MS method for the determination of N-acetylneuraminic acid as a marker of deteriorated ophthalmic solutions.

    Science.gov (United States)

    Iwatsuka, Kinya; Yasueda, Shin-ichi; Bando, Eiji; Fujii, Hiroyuki; Terada, Takashi; Okubo, Hiroya; Iwamoto, Hiroki; Kinoshita, Mitsuhiro; Kakehi, Kazuaki

    2011-10-01

    Methods for determining the deterioration of ophthalmic solutions using both high-performance liquid chromatography (HPLC) with fluorescence detection and liquid chromatography coupled with selected ion monitoring mass spectrometry (LC/MS) are described. The methods are based on the determination of N-acetylneuraminic acid (NeuAc) released by the hydrolysis of foreign bodies that contaminate eye drops during use. The released NeuAc was either labeled with 1,2-diamino-4,5-methylenedioxybenzene (DMB) for fluorometric detection or detected without derivatization by mass spectrometry. The calibration curves for NeuAc showed good linearity between 1.2 ng/mL and 39 ng/mL for fluorometric HPLC and 5.0 ng/mL and 100 ng/mL for LC/MS, respectively. Detection limits for fluorometric HPLC and LC/MS were 0.20 ng/mL and 0.88 ng/mL, respectively. The NeuAc content of some model glycoproteins determined by LC/MS method were 62-78% of those determined by fluorometry. The differences are attributed to matrix effects but the LC/MS method afforded sufficiently high sensitivity that NeuAc in the foreign bodies could be determined in eight of nine test samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation by HPLC.

    Science.gov (United States)

    Patel, Archita; Macwana, Chhaya; Parmar, Vishal; Patel, Samir

    2012-01-01

    An accurate, simple, reproducible, and sensitive HPLC method was developed and validated for the simultaneous determination of atorvastatin calcium, ezetimibe, and fenofibrate in a tablet formulation. The analyses were performed on an RP C18 column, 150 x 4.60 mm id, 5 pm particle size. The mobile phase methanol-acetonitrile-water (76 + 13 + 11, v/v/v), was pumped at a constant flow rate of 1 mL/min. UV detection was performed at 253 nm. Retention times of atorvastatin calcium, ezetimibe, and fenofibrate were found to be 2.25, 3.68, and 6.41 min, respectively. The method was validated in terms of linearity, precision, accuracy, LOD, LOQ, and robustness. The response was linear in the range 2-10 microg/mL (r2 = 0.998) for atorvastatin calcium, 2-10 microg/mL (r2 = 0.998) for ezetimibe, and 40-120 microg/mL (r2 = 0.998) for fenofibrate. The developed method can be used for routine quality analysis of the drugs in the tablet formulation.

  9. Determination of two capsaicinoids in analgesic transdermal patches using RP-HPLC and UV spectroscopy

    Directory of Open Access Journals (Sweden)

    F. Kobarfard

    2017-11-01

    Full Text Available Background and objectives: At the present time, a considerable frontier in the administration of therapeutic medications is transdermal drug delivery. Methods: In this study, a rapid, precise, sensitive and selective reversed-phasehigh performance liquid chromatography (RP-HPLC method has been evaluated, developed and validated to separate and quantitate capsaicin and dihydrocapsaicin (main active agents in analgesic dermal patches produced in Iran. Results: After isolation from laminated adhesive patches, capsaicinoids were analyzed on Lichrospher C18 analytical columns with reversed phase, using a mobile phase composition of methanol and distilled water (70:30 v/v and without any buffer (pH=6.5. The flow rate was 1 mL/min and the UV detector was operating at 281 nm. The assay was found to be linear over the range of 0.1-1.0 mg/mL. All validation parameters were within the acceptable range. Conclusion: It seems that the developed method was fairly sensitive and reliable in measuring capsaicinoids in commercially available analgesic transdermal patches in Iran.

  10. A Simple and Effective Isocratic HPLC Method for Fast Identification and Quantification of Surfactin

    International Nuclear Information System (INIS)

    Muhammad Qadri Effendy Mubarak; Abdul Rahman Hassan; Aidil Abdul Hamid; Sahaid Khalil; Mohd Hafez Mohd Isa

    2015-01-01

    The aim of this study was to establish a simple, accurate and reproducible method for the identification and quantification of surfactin using high-performance liquid chromatography (HPLC). Previously reported method of identification and quantification of surfactin were time consuming and requires a large quantity of mobile phase. The new method was achieved by application of Chromolith® high performance RP-18 (100 x 4.6 mm, 5 μm) as the stationary phase and optimization of mobile phase ratio and flow rate. Mobile phase consisted of acetonitrile (ACN) and 3.8 mM trifluroacetic acid (TFA) solution of 80:20 ratio at flow rate of 2.2 mL/ min was obtained as the optimal conditions. Total elution time of the obtained surfactin peaks was four times quicker than various methods previously reported in the literature. The method described here allowed for fine separation of surfactin in standard sample (98 % purity) and surfactin in fermentation broth. (author)

  11. HPLC-HG-AFS determination of arsenic species in acute promyelocytic leukemia (APL) plasma and blood cells.

    Science.gov (United States)

    Guo, Meihua; Wang, Wenjing; Hai, Xin; Zhou, Jin

    2017-10-25

    Arsenic trioxide (ATO) has been successfully used in the treatment of acute promyelocytic leukemia (APL). To clarify the arsenic species in APL patients, high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry (HPLC-HG-AFS) and HG-AFS methods were developed and validated to quantify the plasma concentrations of inorganic arsenic (As(III) and As(V)) and methylated metabolites (MMA and DMA), and the total amounts of arsenic in blood cells and plasma. Blood cells and plasma were digested with mixtures of HNO 3 H 2 O 2 and analyzed by HG-AFS. For arsenic speciation, plasma samples were prepared with perchloric acid to precipitate protein. The supernatant was separated on an anion-exchange column within 6min with isocratic elution using 13mM CH 3 COONa, 3mM NaH 2 PO 4 , 4mM KNO 3 and 0.2mM EDTA-2Na. The methods provided linearity range of 0.2-20ng/mL for total arsenic and 2.0-50ng/mL for four arsenic species. The developed methods for total arsenic and arsenic species determination were precise and accurate. The spiked recoveries ranged from 81.2%-108.6% and the coefficients of variation for intra- and inter-batch precision were less than 9.3% and 12.5%, respectively. The developed methods were applied successfully for the assay of total arsenic and arsenic species in 5 APL patients. The HPLC-HG-AFS may be a good alternative for arsenic species determination in APL patients with its simplicity and low-cost in comparison with HPLC-ICP-MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A convenient method for the quantitative determination of elemental sulfur in coal by HPLC analysis of perchloroethylene extracts

    Science.gov (United States)

    Buchanan, D.H.; Coombs, K.J.; Murphy, P.M.; Chaven, C.

    1993-01-01

    A convenient method for the quantitative determination of elemental sulfur in coal is described. Elemental sulfur is extracted from the coal with hot perchloroethylene (PCE) (tetrachloroethene, C2Cl4) and quantitatively determined by HPLC analysis on a C18 reverse-phase column using UV detection. Calibration solutions were prepared from sublimed sulfur. Results of quantitative HPLC analyses agreed with those of a chemical/spectroscopic analysis. The HPLC method was found to be linear over the concentration range of 6 ?? 10-4 to 2 ?? 10-2 g/L. The lower detection limit was 4 ?? 10-4 g/L, which for a coal sample of 20 g is equivalent to 0.0006% by weight of coal. Since elemental sulfur is known to react slowly with hydrocarbons at the temperature of boiling PCE, standard solutions of sulfur in PCE were heated with coals from the Argonne Premium Coal Sample program. Pseudo-first-order uptake of sulfur by the coals was observed over several weeks of heating. For the Illinois No. 6 premium coal, the rate constant for sulfur uptake was 9.7 ?? 10-7 s-1, too small for retrograde reactions between solubilized sulfur and coal to cause a significant loss in elemental sulfur isolated during the analytical extraction. No elemental sulfur was produced when the following pure compounds were heated to reflux in PCE for up to 1 week: benzyl sulfide, octyl sulfide, thiane, thiophene, benzothiophene, dibenzothiophene, sulfuric acid, or ferrous sulfate. A sluury of mineral pyrite in PCE contained elemental sulfur which increased in concentration with heating time. ?? 1993 American Chemical Society.

  13. New rapid methods for determination of total LAS in sewage sludge by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE)

    International Nuclear Information System (INIS)

    Villar, M.; Callejon, M.; Jimenez, J.C.; Alonso, E.; Guiraum, A.

    2009-01-01

    Linear alkylbenzene sulfonates (LAS) are the most common synthetic anionic surfactant used in domestic and industrial detergents, with a global production of 2.4 x 10 6 t year -1 . After use and disposal, LAS may enter the environment by one of the several routes, including by direct discharge to surface water or discharge to water from sewage treatment plants. Sewage treatment plants break down LAS only partly: some of them remain in effluent and other fraction is adsorbed in sewage solid. New and rapid methods for determination of total LAS from sewage sludge based on microwave assisted extraction and HPLC-FL and CE-DAD determination are proposed. The extraction of total LAS is carried out by using microwaves energy, an extraction time of 10 min and 5 mL of methanol. For HPLC-FL determination, mobile phase acetonitrile-water was used, comprising 60% (v/v) from 0 to 1 min and a flow rate of 1 mL min -1 programmed to 100% acetonitrile between 1 and 2 min and a flow rate of 2 mL min -1 . The final composition was maintained for a further 5 min. The determination of total LAS by CE-DAD was performed in a phosphate buffer (10 mM, pH 9). The separation voltage was 25 kV and the temperature of the capillary was 30 deg. C. Injections were performed in the pressure mode and the injection time was set at 12 s. The determination of total LAS is carried out in less than 5 min. The methods did not require clean-up or preconcentration steps. Detection limit for total LAS in the sludge was 3.03 mg kg -1 using HPLC-FL and 21.0 mg kg -1 using CE-DAD, and recoveries were >85% using both determination methods. Concentrations of total LAS obtained using both methods were compared with the sum of concentrations of homologues LAS C-10, LAS C-11, LAS C-12 and LAS C-13 obtained using microwaves assisted extraction and HPLC-FL and CE-DAD determination

  14. New rapid methods for determination of total LAS in sewage sludge by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE).

    Science.gov (United States)

    Villar, M; Callejón, M; Jiménez, J C; Alonso, E; Guiraúm, A

    2009-02-23

    Linear alkylbenzene sulfonates (LAS) are the most common synthetic anionic surfactant used in domestic and industrial detergents, with a global production of 2.4x10(6) t year(-1). After use and disposal, LAS may enter the environment by one of the several routes, including by direct discharge to surface water or discharge to water from sewage treatment plants. Sewage treatment plants break down LAS only partly: some of them remain in effluent and other fraction is adsorbed in sewage solid. New and rapid methods for determination of total LAS from sewage sludge based on microwave assisted extraction and HPLC-FL and CE-DAD determination are proposed. The extraction of total LAS is carried out by using microwaves energy, an extraction time of 10 min and 5 mL of methanol. For HPLC-FL determination, mobile phase acetonitrile-water was used, comprising 60% (v/v) from 0 to 1 min and a flow rate of 1 mL min(-1) programmed to 100% acetonitrile between 1 and 2 min and a flow rate of 2 mL min(-1). The final composition was maintained for a further 5 min. The determination of total LAS by CE-DAD was performed in a phosphate buffer (10 mM, pH 9). The separation voltage was 25 kV and the temperature of the capillary was 30 degrees C. Injections were performed in the pressure mode and the injection time was set at 12 s. The determination of total LAS is carried out in less than 5 min. The methods did not require clean-up or preconcentration steps. Detection limit for total LAS in the sludge was 3.03 mg kg(-1) using HPLC-FL and 21.0 mg kg(-1) using CE-DAD, and recoveries were >85% using both determination methods. Concentrations of total LAS obtained using both methods were compared with the sum of concentrations of homologues LAS C-10, LAS C-11, LAS C-12 and LAS C-13 obtained using microwaves assisted extraction and HPLC-FL and CE-DAD determination.

  15. Determination of amphotericin B in PLA-PEG blend nanoparticles by HPLC-PDA

    Directory of Open Access Journals (Sweden)

    Caroline Danziato Rodrigues

    2014-12-01

    Full Text Available In this work, we developed and validated an effective reversed-phase HPLC method with photodiode array (PDA detection for the quantitative analysis of amphotericin B (AmB in poly(lactide-poly(ethylene glycol (PLA-PEG blend nanoparticles. Chromatographic runs were performed on a reverse phase C18 column using a mobile phase comprising a 9% acetic acid and acetonitrile mixture (40:60, v/v under isocratic elution with a flow rate of 1 mL/min. AmB was detected at a wavelength of 408 nm. The validation process was performed considering the selectivity, linearity, precision, accuracy, robustness, limit of detection (LOD and limit of quantitation (LOQ of the method. A concentration range of 1-20 µg/mL was used to construct a linear calibration curve. The LOQ and LOD were 55 and 18 ng/mL, respectively. The mean recovery of AmB from the samples was 99.92% (relative standard deviation (RSD = 0.34%, n=9, and the method was robust for changes in the flow rate of the mobile phase (maximum RSD=4.82%. The intra- and inter-assay coefficients of variation were less than 0.59%. The method was successfully used to determine the entrapment efficiency of AmB in PLA-PEG blend nanoparticles.

  16. Determination of Diacetyl in Beer by a Precolumn Derivatization-HPLC-UV Method Using 4-(2,3-Dimethyl-6-quinoxalinyl)-1,2-benzenediamine as a Derivatizing Reagent.

    Science.gov (United States)

    Wang, Ji-Yu; Wang, Xin-Jie; Hui, Xian; Hua, Shui-Hong; Li, Heng; Gao, Wen-Yun

    2017-03-29

    Diacetyl is an important flavoring compound in many foods, especially in beer. In the present study, we developed and validated a new precolumn derivatization HPLC-UV method for the determination of diacetyl using 4-(2,3-dimethyl-6-quinoxalinyl)-1,2-benzenediamine as a novel derivatizing reagent. After derivatization with the reagent at a pH value 4.0 at ambient temperature for 10 min, diacetyl was analyzed on an ODS column and detected at 254 nm. The results show that the correlation coefficient of the method is 0.9991 in the range of 0.10 to 100.0 μM diacetyl, and the limit of detection is 0.02 μM. The method was further evaluated in the analysis of beer samples with the recoveries ranging from 94.4 to 102.6% and RSDs from 1.36 to 3.33%. The concentrations of diacetyl in 8 beer samples were determined in the range of 0.19 to 0.42 μM. The method established in this study may be well suitable for the determination of diacetyl in beer.

  17. [Determination of rhynchophylline and isorhynchophylline in Uncaria rhynchophylla by HPLC].

    Science.gov (United States)

    Yang, Xiu-Juan; Hong, Yan-Long; Wu, Fei; Ruan, Ke-Feng; Feng, Yi

    2013-03-01

    To explore an HPLC method for determination of rhnchophylline and isorhnchophylline in Uncaria rhnchophylla. An HPLC method has been developed for determination of rhnchophylline and isorhnchophylline. The transformation of rhnchophylline and isorhnchophylline after heating was also studied by HPLC-ESI-MS. Good linearities of rhynchophylline and isorhynchophylline were 0.064-5.100, 0.064-5.110 mg, respectively. The average recoveries were from 87.51% to 88.83% for rhynchophylline and from 107.9% to 113.9% for isorhynchophylline. The recoveries of rhynchophylline and isorhnchophylline reference solutions after extraction were 12.60% and 40.00% in the reflux extraction procedure, respectively. While in the ultrasonic extraction procedure, the average recoveries of rhynchophylline and isorhynchophylline was from 99.48% to 103.2% and from 97.00% to 99.59%, resepectively. The recoveries of rhynchophylline and isorhnchophylline reference solutions after extraction were 47.08% and 51.03%, respectively. The unqualified recovery could be elucidated by HPLC-ESI-MS analysis, indicating that trhynchophylline could be transformed mostly into isorhynchophylline and a little amount of unkown composition, while isorhynchophylline could be transformed into rhynchophylline isocorynoxeine, corynoxeine and 22-O-beta-D-glucopyranosyl isocorynoxeinic acid during the extraction procedure. Ultrasonic extraction procedure was more sutble for HPLC determination of the content of rhynchophylline and isorhynchophylline in U. rhnchophylla, however, the recovery problems should be paid attention to when it comes to the determination.

  18. Assessment of cosmetic ingredients in the in vitro reconstructed human epidermis test method EpiSkin™ using HPLC/UPLC-spectrophotometry in the MTT-reduction assay.

    Science.gov (United States)

    Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P

    2016-06-01

    Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. 2D-HPLC-MS phosphoproteomics analysis of lung and breast carcinomas

    International Nuclear Information System (INIS)

    Rocco, M.; Rubartelli, A.

    2009-01-01

    The project was conceived as two phases. In the first phase, we planned to validate markers, or expression patterns, previously described in the literature as being characteristic of specific tumors. In a second phase, a search for new markers associated with different tumors was to be carried on, developing new 2D-HPLC methods coupled with API-ESI mass spectrometry, with the ultimate goal of their rapid identification in biological specimens. For what concerns the first phase, the most relevant data are described in (Ceccarelli et al., 2008) and further analyzed in (Rubartelli et al., 2007). In these studies, we have compared the synthesis and intracellular accumulation levels of two oxido-reductases having also an extracellular cytokine function, the macrophage inhibitory factor (MIF) and thioredoxin (Trx)

  20. A rapid hydrolysis method and DABS-Cl derivatization for complete amino acid analysis of octreotide acetate by reversed phase HPLC.

    Science.gov (United States)

    Akhlaghi, Yousef; Ghaffari, Solmaz; Attar, Hossein; Alamir Hoor, Amir

    2015-11-01

    Octreotide as a synthetic cyclic octapeptide is a somatostatin analog with longer half-life and more selectivity for inhibition of the growth hormone. The acetate salt of octreotide is currently used for medical treatment of somatostatin-related disorders such as endocrine and carcinoid tumors, acromegaly, and gigantism. Octreotide contains both cysteine and tryptophan residues which make the hydrolysis part of its amino acid analysis procedure very challenging. The current paper introduces a fast and additive-free method which preserves tryptophan and cysteine residues during the hydrolysis. Using only 6 M HCl, this hydrolysis process is completed in 30 min at 150 °C. This fast hydrolysis method followed by pre-column derivatization of the released amino acids with 4-N,N-dimethylaminoazobenzene-4'-sulfonyl chloride (DABS-Cl) which takes only 20 min, makes it possible to do the complete amino acid analysis of an octreotide sample in a few hours. The highly stable-colored DABS-Cl derivatives can be detected in 436 nm in a reversed phase chromatographic system, which eliminates spectral interferences to a great extent. The amino acid analysis of octreotide acetate including hydrolysis, derivatization, and reversed phase HPLC determination was validated according to International Conference of Harmonization (ICH) guidelines.

  1. Determination of 5-fluorouracil in plasma with HPLC-tandem mass spectrometry

    NARCIS (Netherlands)

    van Kuilenburg, A. B. P.; van Lenthe, H.; Maring, J. G.; van Gennip, A. H.

    2006-01-01

    In this article, we describe a fast and specific method to measure 5FU with HPLC tandem-mass spectrometry. Reversed-phase HPLC was combined with electrospray ionization tandem mass spectrometry and detection was performed by multiple-reaction monitoring. Stable-isotope-labeled 5FU (1,3-15N2-5FU) was

  2. The Use of Titrimetric, Nelson Somogyi and Hplc Methods for the Analysis of Cashew Apple Juice Fermentation Broths

    OpenAIRE

    Kantasubrata, Julia; T. Karossi, A; S. Pramudi, A

    1993-01-01

    In cashew apple juice fermentation to produce wine and vinegar, analysis of organic acids and sugars in fermentation broths is very important, due to the fact that optimum conditions of fermentation could only be established from results obtained on monitoring the concentrations of those components during the fermentation process. Analysis of organic acids by tiirimetric method and analysis of sugars by Nelson-Somogyi method only give a total amount of acids and sugars. HPLC is one of the pro...

  3. HPLC/MS analysis of glucose and fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Bruder, P.; Macasek, F.; Patakyova, A.; Buriova, E.

    2001-01-01

    Objective of a new method of FDG analysis development is to replace existing tests by a more complex assay. In this work, a liquid chromatography/refractive index detector/ radiometric detector/mass spectrometric detector combination (HPLC/RID/RAD/MSD) was used for development of a complex routine technique. Optimization of HPLC/MS analysis was performed investigating the MSD analytical signal as a function of various eluent composition. Solutions of glucose in methanol/water and acetonitrile/water solutions of various semi-volatile electrolytes (ammonium chloride, formic acid, ammonium formate) were analyzed on the Agilent 1100 HPLC/RID/DAD/MSD system either in the flow injection (FIA) mode of analysis, and after passing the samples through Zorbax C-18 column. The most intensive signals of the ions were obtained in the acetonitrile : 0.25% ammonium formate = 80:20 solutions. This eluent would be also used for the radioactive FDG analysis on the Asahipak NH2P columns. (authors)

  4. HPLC/MS analysis of glucose and fluorodeoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Bruder, P; Macasek, F; Patakyova, A; Buriova, E [Department of Nuclear Chemistry, Faculty of Natural Sciences, Comenius University, 84215 Bratislava (Slovakia)

    2001-05-31

    Objective of a new method of FDG analysis development is to replace existing tests by a more complex assay. In this work, a liquid chromatography/refractive index detector/ radiometric detector/mass spectrometric detector combination (HPLC/RID/RAD/MSD) was used for development of a complex routine technique. Optimization of HPLC/MS analysis was performed investigating the MSD analytical signal as a function of various eluent composition. Solutions of glucose in methanol/water and acetonitrile/water solutions of various semi-volatile electrolytes (ammonium chloride, formic acid, ammonium formate) were analyzed on the Agilent 1100 HPLC/RID/DAD/MSD system either in the flow injection (FIA) mode of analysis, and after passing the samples through Zorbax C-18 column. The most intensive signals of the ions were obtained in the acetonitrile : 0.25% ammonium formate = 80:20 solutions. This eluent would be also used for the radioactive FDG analysis on the Asahipak NH2P columns. (authors)

  5. Buffer-Free High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a simple, economical and reproducible high performance liquid chromatographic (HPLC) method for the determination of theophylline in pharmaceutical dosage forms. Method: Caffeine was used as the internal standard and reversed phase C-18 column was used to elute the drug and ...

  6. A New HPLC-ELSD Method for Simultaneous Determination of N-Acetylglucosamine and N-Acetylgalactosamine in Dairy Foods

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2015-01-01

    Full Text Available A rapid high performance liquid chromatographic method with evaporative light scattering detection (HPLC-ELSD, using a carbohydrate column, was developed for simultaneous determination of N-acetylglucosamine (GlcNAc and N-acetylgalactosamine (GalNAc in dairy foods. Sample preparation was performed by precipitation using acetonitrile. The limits of detection were 2.097 mg/L for GlcNAc and 3.247 mg/L for GalNAc. The limits of quantification were 6.043 mg/L for GlcNAc and 9.125 mg/L for GalNAc. Accuracy ranged from 96.4 to 105.7% for GlcNAc and from 97.1 to 104.1% for GalNAc. The precision of the method was <1.7% for GlcNAc and <2.2% for GalNAc. The mean recovery of the method was measured by spiking samples with 30.0–120.0 mg/L GlcNAc or 12.5–50.0 mg/L GalNAc and was found to be 95.1–105.5% for GlcNAc and 99.5–105.9% for GalNAc. The stability test results of standard solutions stored at 4, 20, and 40°C were 96.2–104.7% for GlcNAc and 98.0–106.5% for GalNAc. This study determined GlcNAc and GalNAc in dairy foods using HPLC-ELSD method. This rapid, simultaneous quantitation method might be useful as a mean of convenient quality control of dairy foods.

  7. Analytical methods for determination of alkaloids and saponins from roots of Caulophyllum thalictroids (L) Michx using UPLC HPLC and HPTLC

    Science.gov (United States)

    A comparison study of analytical methods including HPLC, UPLC and HPTLC are presented in this paper for the determination of major alkaloid and triterpene saponins from the roots of Caulophyllum thalictroides (L.) Michx. (blue cohosh) and dietary supplements claiming to contain blue cohosh. The meth...

  8. Analysis of anti-neoplastic drug in bacterial ghost matrix, w/o/w double nanoemulsion and w/o nanoemulsion by a validated 'green' liquid chromatographic method.

    Science.gov (United States)

    Youssof, Abdullah M E; Salem-Bekhit, Mounir M; Shakeel, Faiyaz; Alanazi, Fars K; Haq, Nazrul

    2016-07-01

    The objective of the present investigation was to develop and validate a 'green' reversed phase high-performance liquid chromatography (RP-HPLC) method for rapid analysis of a cytotoxic drug 5-fluorouracil (5-FU) in bulk drug, marketed injection, water-in-oil (w/o) nanoemulsion, double water-in-oil-in-water (w/o/w) nanoemulsion and bacterial ghost (BG) matrix. The chromatography study was carried out at room temperature (25±1°C) using an HPLC system with the help of ultraviolet (UV)-visible detector. The chromatographic performance was achieved with a Nucleodur 150mm×4.6mm RP C8 column filled with 5µm filler as a static phase. The mobile phase consisted of ethyl acetate: methanol (7:3% v/v) which was delivered at a flow rate of 1.0mLmin(-1) and the drug was detected in UV mode at 254nm. The developed method was validated in terms of linearity (r(2)=0.998), accuracy (98.19-102.09%), precision (% RSD=0.58-1.17), robustness (% RSD=0.12-0.53) and sensitivity with satisfactory results. The efficiency of the method was demonstrated by the assay of the drug in marketed injection, w/o nanoemulsion, w/o/w nanoemulsion and BG with satisfactory results. The successful resolution of the drug along with its degradation products clearly established the stability-indicating nature of the proposed method. Overall, these results suggested that the proposed analytical method could be effectively applied to the routine analysis of 5-FU in bulk drug, various pharmaceutical dosage forms and BG. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Laboratory Detection and Analysis of Organic Compounds in Rocks Using HPLC and XRD Methods

    Science.gov (United States)

    Dragoi, D.; Kanik, I.; Bar-Cohen, Y.; Sherrit, S.; Tsapin, A.; Kulleck, J.

    2004-01-01

    In this work we describe an analytical method for determining the presence of organic compounds in rocks, limestone, and other composite materials. Our preliminary laboratory experiments on different rocks/limestone show that the organic component in mineralogical matrices is a minor phase on order of hundreds of ppm and can be better detected using high precision liquid chromatography (HPLC). The matrix, which is the major phase, plays an important role in embedding and protecting the organic molecules from the harsh Martian environment. Some rocks bear significant amounts of amino acids therefore, it is possible to identify these phases using powder x-ray diffraction (XRD) by crystallizing the organic. The method of detection/analysis of organics, in particular amino acids, that have been associated with life will be shown in the next section.

  10. Measurement of menadione in urine by HPLC.

    Science.gov (United States)

    Al Rajabi, Ala; Peterson, James; Choi, Sang-Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-09-15

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C(30) column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H(2)O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R(2)) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  11. Simultaneous Determination of Dexamethasone, Ondansetron, Granisetron, Tropisetron, and Azasetron in Infusion Samples by HPLC with DAD Detection

    Directory of Open Access Journals (Sweden)

    Fu-chao Chen

    2017-01-01

    Full Text Available A simple and rapid high-performance liquid chromatography with diode array detector (HPLC-DAD method has been developed and validated for simultaneous quantification of five antiemetic agents in infusion samples: dexamethasone, ondansetron, granisetron, tropisetron, and azasetron. The chromatographic separation was achieved on a Phenomenex C18 column (4.6 mm × 150 mm, 5 μm using acetonitrile-50 mM KH2PO4 buffer-triethylamine (25 : 74 : 1; v/v; pH 4.0. Flow rate was 1.0 mL/min with a column temperature of 30°C. Validation of the method was made in terms of specificity, linearity, accuracy, and intra- and interday precision, as well as quantification and detection limits. The developed method can be used in the laboratory to routinely quantify dexamethasone, ondansetron, granisetron, tropisetron, and azasetron simultaneously and to evaluate the physicochemical stability of referred drugs in mixtures for endovenous use.

  12. Development of an Ion-Pairing Reagent and HPLC-UV Method for the Detection and Quantification of Six Water-Soluble Vitamins in Animal Feed

    Directory of Open Access Journals (Sweden)

    Ho Jin Kim

    2016-01-01

    Full Text Available A novel and simple method for detecting six water-soluble vitamins in animal feed using high performance liquid chromatography equipped with a photodiode array detector (HPLC/PDA and ion-pairing reagent was developed. The chromatographic peaks of the six water-soluble vitamins were successfully identified by comparing their retention times and UV spectra with reference standards. The mobile phase was composed of buffers A (5 mM PICB-6 in 0.1% CH3COOH and B (5 mM PICB-6 in 65% methanol. All peaks were detected using a wavelength of 270 nm. Method validation was performed in terms of linearity, sensitivity, selectivity, accuracy, and precision. The limits of detection (LODs for the instrument employed in these experiments ranged from 25 to 197 μg/kg, and the limits of quantification (LOQs ranged from 84 to 658 μg/kg. Average recoveries of the six water-soluble vitamins ranged from 82.3% to 98.9%. Method replication resulted in intraday and interday peak area variation of <5.6%. The developed method was specific and reliable and is therefore suitable for the routine analysis of water-soluble vitamins in animal feed.

  13. Development of On-Line High Performance Liquid Chromatography (HPLC)-Biochemical Detection Methods as Tools in the Identification of Bioactives

    Science.gov (United States)

    Malherbe, Christiaan J.; de Beer, Dalene; Joubert, Elizabeth

    2012-01-01

    Biochemical detection (BCD) methods are commonly used to screen plant extracts for specific biological activities in batch assays. Traditionally, bioactives in the most active extracts were identified through time-consuming bio-assay guided fractionation until single active compounds could be isolated. Not only are isolation procedures often tedious, but they could also lead to artifact formation. On-line coupling of BCD assays to high performance liquid chromatography (HPLC) is gaining ground as a high resolution screening technique to overcome problems associated with pre-isolation by measuring the effects of compounds post-column directly after separation. To date, several on-line HPLC-BCD assays, applied to whole plant extracts and mixtures, have been published. In this review the focus will fall on enzyme-based, receptor-based and antioxidant assays. PMID:22489144

  14. Determination of soluble dietary fibre content of Okara treated with high hydrostatic pressure and enzymes: a comparative evaluation of two methods (AOAC and HPLC-ELSD).

    Science.gov (United States)

    Pérez-López, E; Mateos-Aparicio, I; Rupérez, P

    2017-04-01

    Okara is a promising by-product from soybean and a rich source of dietary fibre, chiefly insoluble (IDF). To increase its solubility and functionality, a treatment with high hydrostatic pressure (HHP) assisted by food grade enzymes - Ultraflo ® L or Viscozyme ® L- has been performed. To monitor the effectiveness, an analysis of dietary fibre, mainly the soluble fraction (SDF), was accomplished by the AOAC enzymatic-gravimetric method with dialysis followed by both, spectrophotometric methods and High Performance Liquid Chromatography with Evaporative Light Scattering Detector (HPLC-ELSD) analysis of the soluble fraction. A significant increase in SDF (≈1.5-times) to the expense of a decrease in IDF was shown and chromatograms revealed two peaks of 95 and 22 kDa. Thus, treated Okara possessed a more balanced and convenient ratio of soluble to insoluble dietary fibre, which could have health benefits as prebiotic. Inbuilt interferences of the official AOAC's method for dietary fibre were confirmed and the direct HPLC-ELSD approach was about twice more sensitive than spectrophotometric methods. Consequently, the direct HPLC-ELSD analysis of the supernatant is proposed as a cheaper, faster and reliable method. Combined HHP-treatments plus specific enzymes represent a promising alternative for the valorisation and preservation of agrofood by-products.

  15. Development and validation of a high-performance liquid chromatographic method for the determination of cyproterone acetate in human skin.

    Science.gov (United States)

    Henry de Hassonville, Sandrine; Chiap, Patrice; Liégeois, Jean-François; Evrard, Brigitte; Delattre, Luc; Crommen, Jacques; Piel, Géraldine; Hubert, Philippe

    2004-09-21

    In the framework of a preliminary study on the transdermal penetration of cyproterone acetate (CPA), a simple and rapid procedure involving an extraction step coupled to a HPLC-UV determination has been developed for the separation and quantification of CPA in the two main skin layers-epidermis and dermis-after local application. The separation of epidermis and dermis layers was carefully carried out by means of a sharp spatula after skin immersion in heated water at 65 degrees C. The two skin layers were then treated separately according to the same process: (1) sample homogenization by vibration after freezing with liquid nitrogen in a Mikro-Dismembrator; (2) CPA extraction with methanol after addition of the internal standard (betamethasone dipropionate); (3) centrifugation; (4) evaporation of a supernatant aliquot; (5) dissolution of the dry residue in methanol and addition of water; (6) centrifugation; (7) injection of a supernatant aliquot into the HPLC system. The separation was achieved on octadecylsilica stationary phase using a mobile phase consisting in a mixture of acetonitrile and water (40:60 (v/v)). The method was then validated using a new approach based on accuracy profiles over a CPA concentration range from 33 to 667 ng/ml for each skin layer. Finally, the method was successfully applied to the determination of CPA to several skin samples after topical application of different gel formulations containing CPA.

  16. Mitoxantrone Loaded Superparamagnetic Nanoparticles for Drug Targeting: A Versatile and Sensitive Method for Quantification of Drug Enrichment in Rabbit Tissues Using HPLC-UV

    Directory of Open Access Journals (Sweden)

    Rainer Tietze

    2010-01-01

    Full Text Available In medicine, superparamagnetic nanoparticles bound to chemotherapeutics are currently investigated for their feasibility in local tumor therapy. After intraarterial application, these particles can be accumulated in the targeted area by an external magnetic field to increase the drug concentration in the region of interest (Magnetic-Drug-Targeting. We here present an analytical method (HPLC-UV, to detect pure or ferrofluid-bound mitoxantrone in a complex matrix even in trace amounts in order to perform biodistribution studies. Mitoxantrone could be extracted in high yields from different tissues. Recovery of mitoxantrone in liver tissue (5000 ng/g was 76±2%. The limit of quantification of mitoxantrone standard was 10 ng/mL ±12%. Validation criteria such as linearity, precision, and stability were evaluated in ranges achieving the FDA requirements. As shown for pilot samples, biodistribution studies can easily be performed after application of pure or ferrofluid-bound mitoxantrone.

  17. Development and Validation of a Simultaneous RP-HPLCUV/DAD Method for Determination of Polyphenols in Gels Containing S. terebinthifolius Raddi (Anacardiaceae)

    Science.gov (United States)

    Carvalho, Melina G.; Aragão, Cícero F. S; Raffin, Fernanda N.; de L. Moura, Túlio F. A.

    2017-01-01

    Topical gels containing extracts of Schinus terebinthifolius have been used to treat bacterial vaginosis. It has been reported that this species has antimicrobial, anti-inflammatory and anti-ulcerogenic properties, which can be attributed to the presence of phenolic compounds. In this work, a sensitive and selective reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols that could be present in S. terebinthifolius was developed. The method was shown to be accurate and precise. Peak purity and similarity index both exceeded 0.99. Calibration curves were linear over the concentration range studied, with correlation coefficients between 0.9931 and 0.9974. This method was used to determine the polyphenol content of a hydroalcoholic extract and pharmacy-compounded vaginal gel. Although the method is useful to assess the 6 phenolic compounds, some compounds could not be detected in the products. SUMMARY A sensitive, selective, accurate and precise reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols in S. terebinthifolius Raddi Abbreviations used: RP-HPLC-UV/DAD: Reverse Phase High Performance Liquid Chromatograph with Ultraviolet and Diode Array Detector, HPLC: High Performance Liquid Chromatograph, HPLC-UV: High Performance Liquid Chromatograph with Ultraviolet Detector, ANVISA: Brazilian National Health Surveillance Agency, LOD: Limit of detection, LOQ: Limit of quantitation PMID:28539726

  18. Development and optimization of a HPLC-RI method for the determination of major sugars in apple juice and evaluation of the effect of the ripening stage

    Directory of Open Access Journals (Sweden)

    Acácio Antonio Ferreira Zielinski

    2014-03-01

    Full Text Available The sugars in apple juice prove its authenticity and its sensory and nutritional properties. The aim of this study was to develop and validate a simple analytical method using high performance liquid chromatography with refractive index detection (HPLC-RI to determinate and quantify the sugars sucrose, D-glucose, D-fructose, and D-sorbitol polyol in apple juices, as well as to analyze the juices from the Fuji suprema and Lis Gala cultivars at three ripening stages. The analytical performance parameters evaluated indicated that the method was specific for the compounds analyzed, and the linearity of the calibration curves of sugars showed high correlation coefficients (close to 1.0. The limits of detection and quantification are consistent with recommendations available in the literature for this type of matrix. Sample preparation is simple and generates small amount of residues. Over 70% of the sugars were determined in the juices of apples at the pre-ripe stage, with an increase during senescence. This method is applicable for the determination of sugars in juices and evaluation of apple ripening.

  19. Development and validation of a fast RP-HPLC method for determination of methotrexate entrapment efficiency in polymeric nanocapsules.

    Science.gov (United States)

    Sartori, Tatiane; Seigi Murakami, Fabio; Pinheiro Cruz, Ariane; Machado de Campos, Angela

    2008-07-01

    A rapid and effective isocratic chromatographic procedure is successfully developed to determinate methotrexate (MTX) entrapment efficiency (EE) in polymeric nanocapsules using reversed-phase high-performance liquid chromatography. The method employed a RP-C(18) Shimadzu Shim-pack CLC-ODS (150 mm x 4.6 mm, 5 microm) column with mobile phase constituted by a mixture of water-acetonitrile-tetrahydrofuran (65:30:5 v/v/v; pH 3.0) at a flow rate of 0.8 mL/min. The eluate is monitored with a UV detector set at 313 nm. The parameters used in the validation process are: linearity, specificity, precision, accuracy, and limit of quantitation (LOQ). The linearity is evaluated by a calibration curve in the concentration range of 10-50 microg/mL and presented a correlation coefficient of 0.9998. The polymers (PLA or PLA-PEG), oil, and surfactants used in the nanocapsule formulation did not interfere with analysis and the recovery was quantitative. The intra and inter-day assay relative standard deviation were less than 0.72%. Results are satisfactory, and the method proved to be adequate for the determination of methotrexate in nanocapsules formulations.

  20. HPLC determination of flavonoid glycosides in Mongolian Dianthus versicolor Fisch. (Caryophyllaceae) compared with quantification by UV spectrophotometry.

    Science.gov (United States)

    Obmann, Astrid; Purevsuren, Sodnomtseren; Zehl, Martin; Kletter, Christa; Reznicek, Gottfried; Narantuya, Samdan; Glasl, Sabine

    2012-01-01

    Dianthus versicolor is used in traditional Mongolian medicine against liver impairment. Fractions enriched in flavone-di- and triglycosides were shown to enhance bile secretion. Therefore, reliable and accurate analytical methods are needed for the determination of these flavonoids in the crude drug and extracts thereof. To provide a validated HPLC-DAD (diode array detector) method especially developed for the separation of polar flavonoids and to compare the data obtained with those evaluated by UV spectrophotometry. Separations were carried out on an Aquasil® C₁₈-column (4.6 mm × 250.0 mm, 5 µm) with a linear gradient of acetonitrile and water (adjusted to pH 2.8 with trifluoroacetic acid) as mobile phase. Rutoside was employed as internal standard with linear behavior in a concentration range of 0.007-3.5 mg/mL. Accuracy was determined by spiking the crude drug with saponarin resulting in recoveries between 92% and 102%. The method allows the quantification of highly polar flavonoid glycosides and the determination of their total content. For saponarin a linear response was evaluated within the range 0.007-3.5 mg/mL (R²  > 0.9999). It was proven that threefold sonication represents a time-saving, effective and cheap method for the extraction of the polar flavonoid glycosides. The contents determined by HPLC were shown to be in agreement with those obtained employing UV spectrophotometry. The study has indicated that the newly developed HPLC method represents a powerful technique for the quality control of D. versicolor. Ultraviolet spectrophotometry may be used alternatively provided that the less polar flavonoids are removed by purification. Copyright © 2011 John Wiley & Sons, Ltd.

  1. [Spectrophotometric and HPLC evaluation of ceftazidime stability].

    Science.gov (United States)

    Palade, B; Cioroiu, B; Lazăr, Doina; Corciovă, Andreia; Lazăr, M I

    2010-01-01

    In this paper we followed up the stability of ceftazidime, raw material used in drug industry. Matherials and methods: We used three spectrophotometric methods based on ceftazidime property to form complexes with p-chloranilic acid (ac. p-CA), 3-methylbenzothiazolin-2-on hydrazone (MBTH) and N-(1-naphtil) etilendiamine (NEDA) and a chromatographic method (HPLC). Our results revealed that the substances analyzed maintained minimum content allowable.

  2. An HPLC tandem mass spectrometry for quantification of ET-26-HCl and its major metabolite in plasma and application to a pharmacokinetic study in rats.

    Science.gov (United States)

    Chen, Xu; Zhang, Wensheng; Rios, Sandy; Morkos, Miriam B; Ye, Xiaoli; Li, Gen; Jiang, Xuehua; Wang, Zhijun; Wang, Ling

    2018-02-05

    ET-26-HCl is a new analog of etomidate, a short-acting anesthetic drug, with less adrenal cortex inhibition. The pharmacokinetics of ET-26-HCl in rats needs to be determined for future clinical trials in human subjects. In order to facilitate the pharmacokinetic study, a liquid chromatography based tandem mass spectrometric (HPLC-MS/MS) method was developed and validated for quantification of ET-26-HCl and its major metabolite, ET-26-acid. These two compounds and gabapentin (internal standard) were extracted using a protein precipitation method with methanol and detected by Multiple Reaction Monitoring of m/z transition of 275.6-170.9, 217.7-113.1, and 172.5-154.3 for ET-26-HCl, ET-26-acid, and gabapentin respectively. This method was validated in terms of sensitivity, linearity, reproducibility, and stability. The HPLC-MS/MS method was found linear over the concentration ranges of 21.76-4352ng/mL, and 18.62-3724ng/mL with LLOQ of 21.76 and 18.62ng/mL for ET-26-HCl and ET-26-acid respectively. The mean intra-day and inter-day accuracy was between 94.11-107.78%, while the precision was within the limit of 15.0% for all the quality control samples. A pharmacokinetic study was then conducted in rats following intravenous injection of 2.1, 4.2, and 8.4mg/kg. The linear pharmacokinetics of ET-26-HCl was observed over the dose range of 2.1-8.4mg/kg. The average terminal phase elimination half-lives were 0.87 and 1.03h for ET-26-HCl and ET-26-acid respectively. In summary, an HPLC-MS/MS method for quantification of ET-26-HCl in rat plasma has been developed and successfully applied to a pharmacokinetic study. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Effect of fungal mycelia on the HPLC-UV and UV-vis spectrophotometric assessment of mycelium-bound epoxide hydrolase using glycidyl phenyl ether.

    Science.gov (United States)

    Dolcet, Marta M; Torres, Mercè; Canela, Ramon

    2016-06-25

    The use of mycelia as biocatalysts has technical and economic advantages. However, there are several difficulties in obtaining accurate results in mycelium-catalysed reactions. Firstly, sample extraction, indispensable because of the presence of mycelia, can bring into the extract components with a similar structure to that of the analyte of interest; secondly, mycelia can influence the recovery of the analyte. We prepared calibration standards of 3-phenoxy-1,2-propanediol (PPD) in the pure solvent and in the presence of mycelia (spiked before or after extraction) from five fungi (Aspergillus niger, Aspergillus tubingensis, Penicillium aurantiogriseum, Penicillium sp. and Aspergillus terreus). The quantification of PPD was carried out by HPLC-UV and UV-vis spectrophotometry. The manuscript shows that the last method is as accurate as the HPLC method. However, the colorimetric method led to a higher data throughput, which allowed the study of more samples in a shorter time. Matrix effects were evaluated visually from the plotted calibration data and statistically by simultaneously comparing the intercept and slope of calibration curves performed with solvent, post-extraction spiked standards and pre-extraction spiked standards. Significant differences were found between the post- and pre-extraction spiked matrix-matched functions. Pre-extraction spiked matrix-matched functions based on A. tubingensis mycelia, selected as the reference, were validated and used to compensate for low recoveries. These validated functions were successfully applied to the quantification of PPD achieved during the hydrolysis of glycidyl phenyl ether by mycelium-bound epoxide hydrolases and equivalent hydrolysis yields were determined by HPLC-UV and UV-vis spectrophotometry. This study may serve as starting point to implement matrix effects evaluation when mycelium-bound epoxide hydrolases are studied. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Validation and evaluation of an HPLC methodology for the quantification of the potent antimitotic compound (+)-discodermolide in the Caribbean marine sponge Discodermia dissoluta.

    Science.gov (United States)

    Valderrama, Katherine; Castellanos, Leonardo; Zea, Sven

    2010-08-01

    The sponge Discodermia dissoluta is the source of the potent antimitotic compound (+)-discodermolide. The relatively abundant and shallow populations of this sponge in Santa Marta, Colombia, allow for studies to evaluate the natural and biotechnological supply options of (+)-discodermolide. In this work, an RP-HPLC-UV methodology for the quantification of (+)-discodermolide from sponge samples was tested and validated. Our protocol for extracting this compound from the sponge included lyophilization, exhaustive methanol extraction, partitioning using water and dichloromethane, purification of the organic fraction in RP-18 cartridges and then finally retrieving the (+)-discodermolide in the methanol-water (80:20 v/v) fraction. This fraction was injected into an HPLC system with an Xterra RP-18 column and a detection wavelength of 235 nm. The calibration curve was linear, making it possible to calculate the LODs and quantification in these experiments. The intra-day and inter-day precision showed relative standard deviations lower than 5%. The accuracy, determined as the percentage recovery, was 99.4%. Nine samples of the sponge from the Bahamas, Bonaire, Curaçao and Santa Marta had concentrations of (+)-discodermolide ranging from 5.3 to 29.3 microg/g(-1) of wet sponge. This methodology is quick and simple, allowing for the quantification in sponges from natural environments, in situ cultures or dissociated cells.

  5. Development and validation of a rapid chromatographic method for the analysis of flunarizine and its main production impurities

    Directory of Open Access Journals (Sweden)

    Niamh O’Connor

    2013-06-01

    Full Text Available A rapid selective method for the analysis of flunarizine and its associated impurities was developed and validated according to ICH guidelines. The separation was carried out using a Thermo Scientific Hypersil Gold C18 column (50mm×4.6mm i.d., 1.9μm particle size with a gradient mobile phase of acetonitrile–ammonium acetate–tetrabutylammoniumhydrogen sulfate buffer, at a flow rate of 1.8mL/min and UV detection at 230nm. Naturally aged samples were also tested to determine sample stability. A profile of sample and impurity breakdown was also presented. Keywords: Flunarizine, Sub 2μm column, Active pharmaceutical ingredient, HPLC

  6. [Study on HPLC-FPS of raw and processed fructus polygoni orientalis].

    Science.gov (United States)

    Zhai, Yanjun; Zhao, Min; Zhang, Hui; Chu, Zhengyun; Kang, Tingguo

    2010-03-01

    To establish the HPLC fingerprint method of Fructus Polygoni Orientalis before and after processed by choosing taxifolin as reference to compare the changes of chemical composition. HPLC method was emplyed with a gradient elution phase in a flow rate of 1 mL x min(-1) and the detection wavelength of 270 nm. Twenty marker peaks were marked out in the raw samples and 33 marker peaks in the processed product. Methodology met was consistent with the requirement, similarity was exceeded 0.9. This method is stationary, precise and feasible, which provide references of quality control for Fructus Polygoni Orientalis.

  7. Stability-indicating RP-HPLC method for simultaneous determination of gatifloxacin and flurbiprofen in binary combination

    Directory of Open Access Journals (Sweden)

    Islam Ullah Khan

    2014-04-01

    Full Text Available A stability-indicating RP-HPLC method is presented for determination of gatifloxacin and flurbiprofen in binary combination. Gatifloxacin, flurbiprofen and their degradation products were detected at 254 nm using a BDS Hypersil C8 (250 X 4.6 mm, 5 µm column and mixture of 20 mM phosphate buffer (pH 3.0 and methanol 30:70 v/v as mobile phase. Response was linear over the range of 15-105 mg mL-1 for gatifloxacin (r² > 0.998 and of 1.5-10.5 mg mL-1 for flurbiprofen (r² > 0.999. The developed method efficiently separated the analytical peaks from degradation products (peak purity index > 0.9999. The method developed can be applied successfully for determination of gatifloxacin and flurbiprofen in human serum, urine, pharmaceutical formulations, and their stability studies.

  8. High-Performance Liquid Chromatography (HPLC) Quantification of Liposome-Delivered Doxorubicin in Arthritic Joints of Collagen-Induced Arthritis Rats.

    Science.gov (United States)

    Niu, Hongqing; Xu, Menghua; Li, Shuangtian; Chen, Junwei; Luo, Jing; Zhao, Xiangcong; Gao, Chong; Li, Xiaofeng

    2017-04-14

    BACKGROUND Neoangiogenesis occurring in inflamed articular synovium in early rheumatoid arthritis (RA) is characterized by enhanced vascular permeability that allows nanoparticle agents, including liposomes, to deliver encapsulated drugs to arthritic joints and subsequently improve therapeutic efficacy and reduce adverse effects. However, the targeting distribution of liposomes in arthritic joints during RA has not been quantitatively demonstrated. We performed this study to evaluate the targeting distribution of PEGylated doxorubicin liposomes in the arthritic joints of collagen-induced arthritis (CIA) rats by high-performance liquid chromatography (HPLC). MATERIAL AND METHODS Two doxorubicin formulations were administered to CIA rats via tail intravenous injection at a single dose (50 mg/m²). CIA rats were sacrificed and the tissues of the inflamed ankle joints were collected. The content of doxorubicin in the arthritic joints was analyzed by a validated and reproducible HPLC method. A two-way ANOVA for 2×5 factorial design was used for statistical analysis. RESULTS The developed HPLC method was sensitive, precise, and reproducible. The method was successfully applied to quantify doxorubicin content in arthritic tissues. At each time point (6, 12, 24, 48, and 72 h), doxorubicin content in the arthritic joints of the doxorubicin liposome group (DOX-LIP group) was higher than in the free doxorubicin group (DOX group) (P<0.05). In the DOX-LIP group, doxorubicin levels in the arthritic joints increased gradually and significantly in the interval of 6-72 h post-administration. CONCLUSIONS PEGylated doxorubicin liposomes were targeted to, accumulated, and retained in the arthritic joints of CIA rats. The present study indicates that liposome encapsulation increases the therapeutic efficacy of antirheumatic drugs, presenting a promising therapeutic strategy for RA.

  9. Validation of a liquid chromatography-electrospray ionization tandem mass spectrometric method to determine six polyether ionophores in raw, UHT, pasteurized and powdered milk.

    Science.gov (United States)

    Pereira, Mararlene Ulberg; Spisso, Bernardete Ferraz; Jacob, Silvana do Couto; Monteiro, Mychelle Alves; Ferreira, Rosana Gomes; Carlos, Betânia de Souza; da Nóbrega, Armi Wanderley

    2016-04-01

    This study aimed to validate a method developed for the determination of six antibiotics from the polyether ionophore class (lasalocid, maduramicin, monensin, narasin, salinomycin and semduramicin) at residue levels in raw, UHT, pasteurized and powdered milk using QuEChERS extraction and high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS). The validation was conducted under an in-house laboratory protocol that is primarily based on 2002/657/EC Decision, but takes in account the variability of matrix sources. Overall recoveries between 93% and 113% with relative standard deviations up to 16% were obtained under intermediate precision conditions. CCα calculated values did not exceed 20% the Maximum Residue Limit for monensin and 25% the Maximum Levels for all other substances. The method showed to be simple, fast and suitable for verifying the compliance of raw and processed milk samples regarding the limits recommended by Codex Alimentarius and those adopted in European Community for polyether ionophores. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Quantitative estimation of (--hinokinin, a trypanosomicidal marker in Piper cubeba, and some of its commercial formulations using HPLC-PDA

    Directory of Open Access Journals (Sweden)

    Kothapalli Haribabu

    2015-04-01

    Full Text Available The fruits of Piper cubeba have been used in Ayurvedic system of medicine for pain, tastelessness, painful urination and mouth diseases. Among its various chemical constituents, (--hinokinin, a trypanosomicidal dibenzylbutyrolactone lignan, is found in significant quantities. For quality evaluation of P. cubeba fruit and its commercial formulations, there is an urgent need to develop an analytical method based on (--hinokinin. For this purpose, an HPLC method was developed using photo diode array detector and Waters HR C18 column with gradient elution consisting of water and acetonitrile. The developed method was validated as per ICH-Q2B guidelines and found to be accurate, precise and linear over a wide range of concentrations (5–300 µg/mL. (--Hinokinin contents were found to be in the range of 0.005–0.109% (m/m in various P. cubeba samples. The developed method was extended to LC–MS for further identification and characterization of (--hinokinin in samples. The developed method is simple, rapid and specific, and can be used as a tool for quality control of P. cubeba fruits and its commercial formulations. Keywords: Piper cubeba, (--Hinokinin, HPLC, Quality control, Herbal formulations

  11. Metabolic profiling using HPLC allows classification of drugs according to their mechanisms of action in HL-1 cardiomyocytes

    International Nuclear Information System (INIS)

    Strigun, Alexander; Wahrheit, Judith; Beckers, Simone; Heinzle, Elmar; Noor, Fozia

    2011-01-01

    Along with hepatotoxicity, cardiotoxic side effects remain one of the major reasons for drug withdrawals and boxed warnings. Prediction methods for cardiotoxicity are insufficient. High content screening comprising of not only electrophysiological characterization but also cellular molecular alterations are expected to improve the cardiotoxicity prediction potential. Metabolomic approaches recently have become an important focus of research in pharmacological testing and prediction. In this study, the culture medium supernatants from HL-1 cardiomyocytes after exposure to drugs from different classes (analgesics, antimetabolites, anthracyclines, antihistamines, channel blockers) were analyzed to determine specific metabolic footprints in response to the tested drugs. Since most drugs influence energy metabolism in cardiac cells, the metabolite 'sub-profile' consisting of glucose, lactate, pyruvate and amino acids was considered. These metabolites were quantified using HPLC in samples after exposure of cells to test compounds of the respective drug groups. The studied drug concentrations were selected from concentration response curves for each drug. The metabolite profiles were randomly split into training/validation and test set; and then analysed using multivariate statistics (principal component analysis and discriminant analysis). Discriminant analysis resulted in clustering of drugs according to their modes of action. After cross validation and cross model validation, the underlying training data were able to predict 50%-80% of conditions to the correct classification group. We show that HPLC based characterisation of known cell culture medium components is sufficient to predict a drug's potential classification according to its mode of action.

  12. Quantitative determination and sampling of azathioprine residues for cleaning validation in production area.

    Science.gov (United States)

    Fazio, Tatiana Tatit; Singh, Anil Kumar; Kedor-Hackmann, Erika Rosa Maria; Santoro, Maria Inês Rocha Miritello

    2007-03-12

    Cleaning validation is an integral part of current good manufacturing practices in any pharmaceutical industry. Nowadays, azathioprine and several other pharmacologically potent pharmaceuticals are manufactured in same production area. Carefully designed cleaning validation and its evaluation can ensure that residues of azathioprine will not carry over and cross contaminate the subsequent product. The aim of this study was to validate simple analytical method for verification of residual azathioprine in equipments used in the production area and to confirm efficiency of cleaning procedure. The HPLC method was validated on a LC system using Nova-Pak C18 (3.9 mm x 150 mm, 4 microm) and methanol-water-acetic acid (20:80:1, v/v/v) as mobile phase at a flow rate of 1.0 mL min(-1). UV detection was made at 280 nm. The calibration curve was linear over a concentration range from 2.0 to 22.0 microg mL(-1) with a correlation coefficient of 0.9998. The detection limit (DL) and quantitation limit (QL) were 0.09 and 0.29 microg mL(-1), respectively. The intra-day and inter-day precision expressed as relative standard deviation (R.S.D.) were below 2.0%. The mean recovery of method was 99.19%. The mean extraction-recovery from manufacturing equipments was 83.5%. The developed UV spectrophotometric method could only be used as limit method to qualify or reject cleaning procedure in production area. Nevertheless, the simplicity of spectrophotometric method makes it useful for routine analysis of azathioprine residues on cleaned surface and as an alternative to proposed HPLC method.

  13. Simultaneous qualitative and quantitative analysis of phenolic acids and flavonoids for the quality control of Apocynum venetum L. leaves by HPLC-DAD-ESI-IT-TOF-MS and HPLC-DAD.

    Science.gov (United States)

    An, Haijuan; Wang, Hong; Lan, Yuexiang; Hashi, Yuki; Chen, Shizhong

    2013-11-01

    A reliable method based on high performance liquid chromatography-diode array detector-electrospray ionization-ion trap-time of flight-mass spectrometry (HPLC-DAD-ESI-IT-TOF-MS) was developed for the identification of phenolic acids and flavonoids in Apocynum venetum L. leaves and its adulterant, Pocynum hendersonii (Hook. f.) Woodson leaves. A total of 21 compounds were identified or tentatively identified, including 4 phenolic acids and 17 flavonoids. 3-O-caffeoylquinic acid (3-CQA) and caffeic acid were detected for the first time in A. venetum leaves; 4-O-caffeoylquinic acid (4-CQA), 3-CQA, caffeic acid, quercetin-3-O-(6"-O-malonyl)-galactoside, quercetin-3-O-(6"-O-malonyl)-glucoside, kaempferol-3-O-(6"-O-malonyl)-glucoside, kaempferol-3-O-(6"-O-acetyl)-glucoside, and kaempferol-3-O-dihexoside were detected for the first time in P. hendersonii leaves. Cluster analysis was employed to analyze 24 batches of A. venetum leaves and 5 batches of P. hendersonii leaves collected from various regions in China. The analysis, which was based on the 21 compounds, indicated that profiles of these compounds were distinct between the two species, and among A. venetum leaf samples from different origins. 18 of these 21 compounds were selected as the markers and simultaneously analyzed by HPLC-DAD for the first time. The quantitative analytical method was validated and subsequently applied to the comprehensive quality evaluation of 24 batches of A. venetum leaves. © 2013 Elsevier B.V. All rights reserved.

  14. Simultaneous RP-HPLC determination of sparfloxacin and dexamethasone in pharmaceutical formulations

    Directory of Open Access Journals (Sweden)

    Syed Naeem Razzaq

    2013-06-01

    Full Text Available The present study describes the development and subsequent validation of simple and accurate stability indicating RP-HPLC method for the determination of sparfloxacin and dexamethasone in pharmaceutical formulations in the presence of their stress-induced degradation products. Both the drugs and their stress-induced degradation products were separated within 10 minutes using C8 column and mixture of methanol and 0.02 M phosphate buffer pH 3.0 (60:40 v/v, respectively as mobile phase at 270 nm using diode array detector. Regression analysis showed linearity in the range of 15-105 µg/mL for sparfloxacin and 5-35 µg/mL for dexamethasone. All the analytes were adequately resolved with acceptable tailing. Peak purity of the two drugs was also greater than 0.9999, showing no co-elution peaks. The developed method was applied for simultaneous determination of sparfloxacin and dexamethasone in pharmaceutical formulations for stability studies.

  15. Validace HPLC metody stanovení piroxikamu v plasmě s využitím SPME a deproteinace

    OpenAIRE

    Kuželová, Kristýna

    2015-01-01

    Validation of HPLC evaluatoin of piroxicam in plasma using SPME and precipitation Rigorous Thesis Mgr. Kristýna Kuželová Charles University in Prague, Faculty of Pharmacy in Hradec Kralove, Department of Pharmaceutical Chemistry and Drug Control, Heyrovského 1203, Hradec Králové The purpose of this thesis was bioanalytical evalution of piroxicam using High Performance Liquid Chromatagraphy (HPLC). Piroxicam was isolated from plasma using SPME and protein precipitacion. Plasma was adjusted to ...

  16. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    Science.gov (United States)

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  17. Effective method for the detection of piroxicam in human plasma using HPLC

    Directory of Open Access Journals (Sweden)

    Adriana Maria CALVO

    2016-01-01

    Full Text Available Abstract Non-steroidal anti-inflammatory drugs (NSAIDs are widely used by the general population to alleviate inflammation and pain after oral surgeries. Piroxicam is among the most commonly used NSAIDs and excels in controlling pain, swelling, trismus and other common symptoms of inflammation. This study aimed to evaluate different concentrations of piroxicam and its major metabolite, 5’-hydroxypiroxicam, in human plasma samples over time using high performance liquid chromatography (HPLC after liquid-liquid extraction. Briefly, 10 volunteers participated in this study after approval by the Ethics Committee of Bauru School of Dentistry, Universidade de São Paulo – USP, Brazil. Volunteers received a single dose oral of piroxicam (20 mg and had blood collected at various times following an established protocol. The methodology of liquid-liquid extraction was effective for determining concentrations of piroxicam in plasma using HPLC in 10 out of 10 volunteers while 5’-hydroxypiroxicam was only detected in 2 out of 10 volunteers.

  18. Effective method for the detection of piroxicam in human plasma using HPLC.

    Science.gov (United States)

    Calvo, Adriana Maria; Prado, Mariel Tavares de Oliveira; Dionísio, Thiago José; Marques, Maria Paula; Brozoski, Daniel Thomas; Lanchote, Vera Lúcia; Faria, Flávio Augusto Cardoso; Santos, Carlos Ferreira

    2016-05-20

    Non-steroidal anti-inflammatory drugs (NSAIDs) are widely used by the general population to alleviate inflammation and pain after oral surgeries. Piroxicam is among the most commonly used NSAIDs and excels in controlling pain, swelling, trismus and other common symptoms of inflammation. This study aimed to evaluate different concentrations of piroxicam and its major metabolite, 5'-hydroxypiroxicam, in human plasma samples over time using high performance liquid chromatography (HPLC) after liquid-liquid extraction. Briefly, 10 volunteers participated in this study after approval by the Ethics Committee of Bauru School of Dentistry, Universidade de São Paulo - USP, Brazil. Volunteers received a single dose oral of piroxicam (20 mg) and had blood collected at various times following an established protocol. The methodology of liquid-liquid extraction was effective for determining concentrations of piroxicam in plasma using HPLC in 10 out of 10 volunteers while 5'-hydroxypiroxicam was only detected in 2 out of 10 volunteers.

  19. A Validated Stability Indicating RP-HPLC Method for the Determination of Emtricitabine, Tenofovir Disoproxil Fumarate, Elvitegravir and Cobicistat in Pharmaceutical Dosage Form

    Science.gov (United States)

    Runja, Chinnalalaiah; Ravi Kumar, Pigili; Avanapu, Srinivasa Rao

    2016-01-01

    A new simple, rapid stability indicating assay method has been developed and validated for the determination of emtricitabine, tenofovir disoproxil fumarate, elvitegravir and cobicistat using reverse-phase high-performance liquid chromatography in their pharmaceutical dosage form. The chromatographic separation was performed on an ODS column (250 × 4.6 mm, 5 µm) using mobile phase A (potassium dihydrogen orthophosphate, pH adjusted to 2.5) and mobile phase B (acetonitrile) in the ratio of 55:45% v/v at a flow rate of 1 mL/min. The analytes were detected at 250 nm. The method was found to be linear in the concentration range of 2–12 µg/mL for EMT, 3–18 µg/mL for TNDF, 1.5–9 µg/mL for ELV and COB, with the coefficient value (R2) of >0.9990. The accuracy was measured via recovery studies and found to be acceptable, and the percentage recoveries were found in the range of 99.93–100.08 ± 0.5%. Forced degradation studies were also conducted, and the drugs were subjected to various stress conditions such as acid hydrolysis, base hydrolysis, oxidative, photolytic and thermal degradation. The proposed method was successfully validated and applied for the quantitative estimation of these drugs in both bulk and tablet dosage forms. PMID:26865655

  20. Simultaneous quantification of flavonoids and triterpenoids in licorice using HPLC.

    Science.gov (United States)

    Wang, Yuan-Chuen; Yang, Yi-Shan

    2007-05-01

    Numerous bioactive compounds are present in licorice (Glycyrrhizae Radix), including flavonoids and triterpenoids. In this study, a reversed-phase high-performance liquid chromatography (HPLC) method for simultaneous quantification of three flavonoids (liquiritin, liquiritigenin and isoliquiritigenin) and four triterpenoids (glycyrrhizin, 18alpha-glycyrrhetinic acid, 18beta-glycyrrhetinic acid and 18beta-glycyrrhetinic acid methyl ester) from licorice was developed, and further, to quantify these 7 compounds from 20 different licorice samples. Specifically, the reverse-phase HPLC was performed with a gradient mobile phase composed of 25 mM phosphate buffer (pH 2.5)-acetonitrile featuring gradient elution steps as follows: 0 min, 100:0; 10 min, 80:20; 50 min, 70:30; 73 min, 50:50; 110 min, 50:50; 125 min, 20:80; 140 min, 20:80, and peaks were detected at 254 nm. By using our technique, a rather good specificity was obtained regarding to the separation of these seven compounds. The regression coefficient for the linear equations for the seven compounds lay between 0.9978 and 0.9992. The limits of detection and quantification lay in the range of 0.044-0.084 and 0.13-0.25 microg/ml, respectively. The relative recovery rates for the seven compounds lay between 96.63+/-2.43 and 103.55+/-2.77%. Coefficient variation for intra-day and inter-day precisions lay in the range of 0.20-1.84 and 0.28-1.86%, respectively. Based upon our validation results, this analytical technique is a convenient method to simultaneous quantify numerous bioactive compounds derived from licorice, featuring good quantification parameters, accuracy and precision.