WorldWideScience

Sample records for hit calibration dawn

  1. Red Dawn: Characterizing Iron Oxide Minerals in Atmospheric Dust

    Science.gov (United States)

    Yauk, K.; Ottenfeld, C. F.; Reynolds, R. L.; Goldstein, H.; Cattle, S.; Berquo, T. S.; Moskowitz, B. M.

    2012-12-01

    Atmospheric dust is comprised of many components including small amounts of iron oxide minerals. Although the iron oxides make up a small weight percent of the bulk dust, they are important because of their roles in ocean fertilization, controls on climate, and as a potential health hazard to humans. Here we report on the iron oxide mineralogy in dust from a large dust storm, dubbed Red Dawn, which engulfed eastern Australia along a 3000 km front on 23 September 2009. Red Dawn originated from the lower Lake Eyre Basin of South Australia, western New South Wales (NSW) and southwestern Queensland and was the worst dust storm to have hit the city of Sydney in more than 60 years. Dust samples were collected from various locations across eastern Australia (Lake Cowal, Orange, Hornsby, Sydney) following the Red Dawn event. Our dust collection provides a good opportunity to study the physical and mineralogical properties of iron oxides from Red Dawn using a combination of reflectance spectroscopy, Mössbauer spectroscopy (MB), and magnetic measurements. Magnetization measurements from 20-400 K reveal that magnetite/maghemite, hematite and goethite are present in all samples with magnetite occurring in trace amounts (effects (d< 100 nm). Finally, we compared reflectance with a magnetic parameter (hard isothermal remanent magnetization, HIRM) for ferric oxide abundance to assess the degree to which ferric oxide in these samples might absorb solar radiation. In samples for which both parameters were obtained, HIRM and average reflectance over the visible wavelengths are correlated as a group (r2=0.24). These results indicate that the ferric oxide minerals in Red Dawn dust absorb solar radiation. Much of this ferric oxide occurs likely as grain coatings of nanohematite and nanogoethite, thereby providing high surface area to enhance absorption of solar radiation.

  2. Cosmic Dawn with WFIRST

    Science.gov (United States)

    Rhoads, James

    Central objectives: WFIRST-AFTA has tremendous potential for studying the epoch of "Cosmic Dawn" the period encompassing the formation of the first galaxies and quasars, and their impact on the surrounding universe through cosmological reionization. Our goal is to ensure that this potential is realized through the middle stages of mission planning, culminating in designs for both WFIRST and its core surveys that meet the core objectives in dark energy and exoplanet science, while maximizing the complementary Cosmic Dawn science. Methods: We will consider a combined approach to studying Cosmic Dawn using a judicious mixture of guest investigator data analysis of the primary WFIRST surveys, and a specifically designed Guest Observer program to complement those surveys. The Guest Observer program will serve primarily to obtain deep field observations, with particular attention to the capabilities of WFIRST for spectroscopic deep fields using the WFI grism. We will bring to bear our years of experience with slitless spectroscopy on the Hubble Space Telescope, along with an expectation of JWST slitless grism spectroscopy. We will use this experience to examine the implications of WFIRST’s grism resolution and wavelength coverage for deep field observations, and if appropriate, to suggest potential modifications of these parameters to optimize the science return on WFIRST. We have assembled a team of experts specializing in (1) Lyman Break Galaxies at redshifts higher than 7 (2) Quasars at high redshifts (3) Lyman-alpha galaxies as probes of reionization (4) Theoretical simulations of high-redshift galaxies (5) Simulations of grism observations (6) post-processing analysis to find emission line galaxies and high redshift galaxies (7) JWST observations and calibrations. With this team we intend to do end-to-end simulations starting with halo populations and expected spectra of high redshift galaxies and finally extracting what we can learn about (a) reionization

  3. Surface Mineralogy Mapping of Ceres from the Dawn Mission

    Science.gov (United States)

    McCord, T. B.; Zambon, F.

    2017-12-01

    Ceres' surface composition is of special interest because it is a window into the interior state and the past evolution of this dwarf planet. Disk-integrated telescopic spectral observations indicated that Ceres' surface is hydroxylated, similar to but not exactly the same as some of the carbonaceous chondrite classes of meteorites. Furthermore, Ceres' bulk density is low, indicating significant water content. The Dawn mission in orbit around Ceres, provided a new and larger set of observations on the mineralogy, molecular and elemental composition, and their distributions in association with surface features and geology. A set of articles was prepared, from which this presentation is derived, that is the first treatment of the entire surface composition of Ceres using the complete High Altitude Mapping Orbit (HAMO) Dawn Ceres data set and the calibrations from all the Dawn instruments. This report provides a current and comprehensive view of Ceres' surface composition and integrates them into general conclusions. Ceres' surface composition shows a fairly uniform distribution of NH4- and Mg-phyllosilicates, carbonates, mixed with a dark component. The widespread presence of phyllosilicates, and salts on Ceres' surface is indicative of the presence of aqueous alteration processes, which involved the whole dwarf planet. There is also likely some contamination by low velocity infall, as seen on Vesta, but it is more difficult to distinguish this infall from native Ceres material, unlike for the Vesta case.

  4. Reconciling the dawn-dusk asymmetry in Mercury's exosphere with the micrometeoroid impact directionality

    OpenAIRE

    Pokorný, Petr; Sarantos, Menelaos; Janches, Diego

    2017-01-01

    Combining dynamical models of dust from Jupiter Family Comets and Halley-type Comets, we demonstrate that the seasonal variation of the dust/meteoroid environment at Mercury is responsible for producing the dawn-dusk asymmetry in Mercury's exosphere observed by the MESSENGER spacecraft. Our latest models, calibrated recently from ground-based and space-borne measurements, provide unprecedented statistics that enable us to study the longitudinal and latitudinal distribution of meteoroids impac...

  5. Offline calibration procedure of the CMS Drift Tube detectors

    International Nuclear Information System (INIS)

    Abbiendi, G; Battilana, C; Cavallo, F R; Giunta, M; Guiducci, L; Amapane, N; Bolognesi, S; Cerminara, G; Bellan, R; Biallass, P; Frangenheim, J; Biasotto, M; Tazon, A Calderon; Cepeda, M; Cruz, B De La; Pardos, C Diez; Bedoya, C Fernandez; Iglesias, M C Fouz; Menendez, J Fernandez; Gresele, A

    2009-01-01

    The barrel region of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider is instrumented with Drift Tube (DT) detectors. This paper describes in full details the calibration of the DT hit reconstruction algorithm. After inter-channel synchronization has been verified through the appropriate hardware procedure, the time pedestals are extracted directly from the distribution of the recorded times. Further corrections for time-of-flight and time of signal propagation are applied as soon as the three-dimensional hit position within the DT chamber is known. The different effects of the time pedestal miscalibration on the two main hit reconstruction algorithms are shown. The drift velocity calibration algorithm is based on the meantimer technique. Different meantimer relations for different track angles and patterns of hit cells are used. This algorithm can also be used to determine the uncertainty on the reconstructed hit position.

  6. Calibration pipeline for VIR data

    Science.gov (United States)

    Carraro, F.; Fonte, S.; Coradini, A.; Filacchione, G.; de Sanctis, M. C.; Ammannito, E.; Capria, M. T.; Cartacci, M.; Noschese, R.; Tosi, F.; Capaccioni, F.

    2011-10-01

    During the second quarter of 2011 VIR-MS (VIS and IR Mapping Spectrometer) [1] aboard Dawn mission [2] has approached Vesta in order to start a long period of acquisitions that will end at the beginning of 2012. Data acquired by each instrument always require a calibration process in order to remove all the instrument effects that could affect the scientific evaluations and analysis. VIR-MS instrument team has realized a calibration pipeline which has the goal of producing calibrated (1b level) data starting from the raw (1a level) ones. The other goal of the tool has been the check of the goodness of acquired data by means of the evaluation of a series of minimum requisites of each data file, such as the percentage of the saturated pixels, the presence of spikes or the mean S/N ratio of each qube.

  7. Dawn: Testing Paradigms by Exploring Dichotomies

    Science.gov (United States)

    Russell, C. T.; Schmidt, B. E.; Wise, J.; Ristvey, J.; Raymond, C. A.

    2010-12-01

    NASA’s Dawn mission represents a series of “firsts” for major NASA missions. Dawn is the first major NASA science mission to use ion propulsion engines, allowing Dawn to be the first mission to orbit one target and then leave its gravity well to explore a second destination. Dawn is the first science mission to the main asteroid belt, reaching protoplanet Vesta in summer 2011, and will be the first mission to reach a “dwarf planet” when it arrives at Ceres in 2015. By targeting both Vesta and Ceres, Dawn explores two intriguing dichotomies in the solar system, that of the dry rocky planets and the wet icy bodies (Fire and Ice) and the dichotomy between planets and asteroids. Is there a clear dividing line here? Vesta, the second most massive asteroid, is a protoplanet: a round, mostly intact asteroid that bears more resemblance to a planet than to smaller asteroids. Vesta is also the likely parent body of the HED meteorites that richly populate Earth’s meteorite collections. It is possible to hold a piece of Vesta in your hands. From the HED meteorites, scientists have learned the Vesta is one of few differentiated asteroids. And from its spectrum, rich in basaltic minerals, it is known to be much like a mini-version of Earth’s Moon and Mercury. Vesta’s surface once was home to floods of lava not unlike those found still today on the Earth. Vesta is very similar to a terrestrial planet. Ceres is the giant of the asteroid belt with a hydrostatic shape that earns it a dwarf planet classification. Like its larger cousins, Ceres’ round shape suggests that the body may be differentiated, but due to its low density, Ceres’ interior is more like an icy moon of Jupiter. Beneath a relatively thin clay veneer probably lies an ice-rich mantle and rocky core, and even possibly a liquid ocean. With such enticing questions posed for Vesta and Ceres, Dawn will enable scientists and the public alike to explore how planets were born, how fire and ice have shaped

  8. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  9. The Dawn Topography Investigation

    Science.gov (United States)

    Raymond, C. A.; Jaumann, R.; Nathues, A.; Sierks, H.; Roatsch, T.; Preusker, E; Scholten, F.; Gaskell, R. W.; Jorda, L.; Keller, H.-U.; hide

    2011-01-01

    The objective of the Dawn topography investigation is to derive the detailed shapes of 4 Vesta and 1 Ceres in order to create orthorectified image mosaics for geologic interpretation, as well as to study the asteroids' landforms, interior structure, and the processes that have modified their surfaces over geologic time. In this paper we describe our approaches for producing shape models, plans for acquiring the needed image data for Vesta, and the results of a numerical simulation of the Vesta mapping campaign that quantify the expected accuracy of our results. Multi-angle images obtained by Dawn's framing camera will be used to create topographic models with 100 m/pixel horizontal resolution and 10 m height accuracy at Vesta, and 200 m/pixel horizontal resolution and 20 m height accuracy at Ceres. Two different techniques, stereophotogrammetry and stereophotoclinometry, are employed to model the shape; these models will be merged with the asteroidal gravity fields obtained by Dawn to produce geodetically controlled topographic models for each body. The resulting digital topography models, together with the gravity data, will reveal the tectonic, volcanic and impact history of Vesta, and enable co-registration of data sets to determine Vesta's geologic history. At Ceres, the topography will likely reveal much about processes of surface modification as well as the internal structure and evolution of this dwarf planet.

  10. 42 CFR 495.344 - Approval of the State Medicaid HIT plan, the HIT PAPD and update, the HIT IAPD and update, and...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Approval of the State Medicaid HIT plan, the HIT PAPD and update, the HIT IAPD and update, and the annual HIT IAPD. 495.344 Section 495.344 Public... Requirements Specific to the Medicaid Program § 495.344 Approval of the State Medicaid HIT plan, the HIT PAPD...

  11. Dawn of Science

    Indian Academy of Sciences (India)

    Dawn of Science - The Healing Art. T Padmanabhan. Series Article Volume 15 Issue 10 October 2010 pp 870-874. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/015/10/0870-0874. Keywords. Surgery; Charaka Samhita; Hippocrates; acupuncture; Galen. Author Affiliations.

  12. Dawn of Science

    Indian Academy of Sciences (India)

    identification has made several historians doubt whether Imhotep really existed; probably he is no more real than Viswakarma of. Indian epics. But the man who designed the pyramids does deserve a mention while describing the dawn of science. Moving lightly over a thousand years, we come across the next milestone ...

  13. Dignity and Dawn: Libya’s Escalating Civil War

    Directory of Open Access Journals (Sweden)

    Daveed Gartenstein-Ross

    2015-02-01

    Full Text Available In this Research Paper, ICCT Associate Fellow Dr. Daveed Gartenstein-Ross and Nathaniel Barr provides a detailed examination of the armed conflict in Libya between the Operation Dignity and Libya Dawn military coalitions. The conflict erupted in May 2014, when Dignity leader Khalifa Hifter announced the launch of his campaign, which was aimed at ridding eastern Libya of Islamist militias, beginning with Benghazi. This offensive shattered a fragile status quo. Revolutionary forces concentrated in the city of Misrata and Islamist politicians perceived Hifter’s offensive as a direct affront and, following parliamentary elections that these factions lost, the Misrata-Islamist bloc announced the launch of the Libya Dawn offensive, aimed at driving pro-Dignity forces out of Tripoli. More broadly, the Dawn offensive was an effort to change facts on the ground in order to ensure that the Misrata-Islamist bloc retained political influence. The Dignity and Dawn offensives have contributed to the continuing political and geographic fragmentation of Libya. Libya now has two separate parliaments and governments, while much of the country has been carved into spheres of influence by warring factions. The Dignity-Dawn conflict has also caused a deterioration of security, which has played into the hands of a variety of violent non-state actors, including al-Qaeda and Islamic State affiliates that have capitalized on Libya’s security vacuum to establish bases of operation. This report provides a blow-by-blow account of the military conflict between Dignity and Dawn forces, then assesses the implications of the Libyan civil war on regional security and potential policy options for Western states.

  14. Dawn at Vesta: testing the protoplanetary paradigm

    Science.gov (United States)

    Russell, C.T.; Raymond, C.A.; Coradini, A.; McSween, H.Y.; Zuber, M.T.; Nathues, A.; DeSanctis, Maria-Cristina; Jaumann, R.; Konopliv, A.S.; Preusker, F.; Asmar, S.W.; Park, R.S.; Gaskell, R.; Keller, H.U.; Mottola, S.; Roatsch, T.; Scully, J.E.C.; Smith, D.E.; Tricarico, P.; Toplis, M.J.; Christensen, U.R.; Feldman, W.C.; Lawrence, D.J.; McCoy, T.J.; Prettyman, T.H.; Reedy, R.C.; Sykes, M.E.; Titus, T.N.

    2012-01-01

    The Dawn spacecraft targeted 4 Vesta, believed to be a remnant intact protoplanet from the earliest epoch of solar system formation, based on analyses of howardite-eucrite-diogenite (HED) meteorites that indicate a differentiated parent body. Dawn observations reveal a giant basin at Vesta's south pole, whose excavation was sufficient to produce Vesta-family asteroids (Vestoids) and HED meteorites. The spatially resolved mineralogy of the surface reflects the composition of the HED meteorites, confirming the formation of Vesta's crust by melting of a chondritic parent body. Vesta's mass, volume, and gravitational field are consistent with a core having an average radius of 107 to 113 kilometers, indicating sufficient internal melting to segregate iron. Dawn's results confirm predictions that Vesta differentiated and support its identification as the parent body of the HEDs.

  15. Dawn of Science

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 16; Issue 7. Dawn of Science-The Galilean World. T Padmanabhan. Series Article Volume 16 Issue 7 July 2011 pp 663-669. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/016/07/0663-0669. Keywords.

  16. Dawn of Science

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 4. Dawn of Science - All was Light - 11. T Padmanabhan. Series Article Volume 17 Issue 4 April 2012 pp 324-329. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/017/04/0324-0329. Keywords.

  17. 77 FR 32639 - HIT Standards Committee and HIT Policy Committee; Call for Nominations

    Science.gov (United States)

    2012-06-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee and HIT Policy Committee; Call for... Health Information Technology Policy Committee (HITPC). Name of Committees: HIT Standards Committee and HIT Policy Committee. General Function of the Committees: The HITSC is charged to provide...

  18. Hit Parade

    DEFF Research Database (Denmark)

    Backe, Hans-Joachim

    2017-01-01

    Daniel Cermak-Sassenrath, Max Alexander Wrighton, Hans-Joachim Backe. Hit Parade. Installation. Kulturnatten 2017, ITU, Copenhagen, DK, Oct 13, 2017.......Daniel Cermak-Sassenrath, Max Alexander Wrighton, Hans-Joachim Backe. Hit Parade. Installation. Kulturnatten 2017, ITU, Copenhagen, DK, Oct 13, 2017....

  19. Hit Parade

    DEFF Research Database (Denmark)

    Cermak, Daniel; Wrighton, Max Alexander; Backe, Hans-Joachim

    2016-01-01

    Daniel Cermak-Sassenrath, Max Alexander Wrighton, Hans-Joachim Backe. Hit Parade. Installation. Demo Night, ITU, Copenhagen, DK, Oct 5, 2016.......Daniel Cermak-Sassenrath, Max Alexander Wrighton, Hans-Joachim Backe. Hit Parade. Installation. Demo Night, ITU, Copenhagen, DK, Oct 5, 2016....

  20. NIMROD Simulations of the HIT-SI and HIT-SI3 Devices

    Science.gov (United States)

    Morgan, Kyle; Jarboe, Tom; Hossack, Aaron; Chandra, Rian; Everson, Chris

    2017-10-01

    The Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI) experiment uses a set of inductively driven helicity injectors to apply non-axisymmetric current drive on the edge of the plasma, driving an axisymmetric spheromak equilibrium in a central confinement volume. Significant improvements have been made to extended MHD modeling of HIT-SI, with both the resolution of disagreement at high injector frequencies in HIT-SI in addition to successes with the new upgraded HIT-SI3 device. Previous numerical studies of HIT-SI, using a zero-beta eMHD model, focused on operations with a drive frequency of 14.5 kHz, and found reduced agreement with both the magnetic profile and current amplification at higher frequencies (30-70 kHz). HIT-SI3 has three helicity injectors which are able to operate with different mode structures of perturbations through the different relative temporal phasing of the injectors. Simulations that allow for pressure gradients have been performed in the parameter regimes of both devices using the NIMROD code and show improved agreement with experimental results, most notably capturing the observed Shafranov-shift due to increased beta observed at higher finj in HIT-SI and the variety of toroidal perturbation spectra available in HIT-SI3. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences under Award Number DE-FG02- 96ER54361.

  1. Hit Parade

    DEFF Research Database (Denmark)

    Cermak, Daniel; Wrighton, Max Alexander; Backe, Hans-Joachim

    2016-01-01

    Daniel Cermak-Sassenrath, Max Alexander Wrighton, Hans-Joachim Backe. Hit Parade. Installation. Kulturnatten 2016, Danish Science Ministry, Copenhagen, DK, Oct 14, 2016.......Daniel Cermak-Sassenrath, Max Alexander Wrighton, Hans-Joachim Backe. Hit Parade. Installation. Kulturnatten 2016, Danish Science Ministry, Copenhagen, DK, Oct 14, 2016....

  2. The Enabling Use of Ion Propulsion on Dawn

    Science.gov (United States)

    Rayman, M.; Russell, C. T.; Raymond, C. A.; Mase, R. M.

    2011-12-01

    Dawn's mission to orbit both Vesta and Ceres is enabled by its use of ion propulsion. Even orbiting Vesta alone with conventional propulsion would have been unaffordable within the constraints of the Discovery Program, and orbiting both would have been impossible. In fact, no other spacecraft has been targeted to orbit two solar system destinations, which is only one of the many firsts that Dawn will achieve. The successful testing of ion propulsion on Deep Space 1 paved the way for Dawn not only to use the hardware with confidence but also to learn how to design the flight system and design the mission to take advantage of its capabilities. In addition to allowing Dawn to reach these two important targets, ion propulsion allows the spacecraft to accomplish significant changes in its orbit. Therefore, science observations of Vesta are planned from four different orbits, at varying altitudes and solar geometry. The use of ion propulsion results in a significant mission design effort since the trajectory is constantly being refined. This also creates a flexible mission architecture, which allows for optimization of the mission as conditions change. Solar electric ion propulsion is especially well suited to missions to the Main Asteroid Belt since solar energy is still a viable power source, whereas the size of the solar array needed beyond 3.5 AU is a potential limitation. Dawn has already surpassed the record for greatest propulsive velocity, but its greatest achievements will no doubt be the incredible bounty of science data enabled by this innovative flight system.

  3. Meet EPA researcher Dawn King

    Science.gov (United States)

    Research microbiologist Dawn King works in EPA’s National Exposure Research Laboratory where she identifies and assesses the health risk of microbial pathogens in water. This is her researchers at work profile.

  4. Effect of simulated dawn on quality of sleep – a community-based trial

    Directory of Open Access Journals (Sweden)

    Haukka Jari

    2003-10-01

    Full Text Available Abstract Background Morning light exposure administered as simulated dawn looks a promising method to treat Seasonal Affective Disorder, but it may moreover help with resetting the inaccurate organisation of body clock functions relative to sleep occurring in winter among people in general. Disturbances in sleep patterns are common and may compromise wellbeing even in the short term. Our hypothesis was that simulated dawn could improve the subjective quality of sleep during winter. Methods A community-based trial with 100 volunteer subjects provided with dawn simulators. Study period lasted for eight weeks, and subjects used the dawn simulators for two weeks at a time, each subject acting as his own control (ABAB-design. Main outcome measure was subjective quality of sleep recorded each morning with Groningen Sleep Quality Scale. Results 77 subjects completed the trial. Quality of sleep improved while subjects were using dawn simulator-devices (p = 0.001. The treatment became beneficial after six days' use of dawn simulator, but the effect did not last after the use was ceased. Conclusion Dawn simulation may help to improve the subjective quality of sleep, but the benefits are modest. Further research is needed to verify these findings and to elucidate the mechanism by which dawn simulation acts on the sleep-wake pattern.

  5. Post-hit dynamics of price limit hits in the Chinese stock markets

    Science.gov (United States)

    Wu, Ting; Wang, Yue; Li, Ming-Xia

    2017-01-01

    Price limit trading rules are useful to cool off traders short-term trading mania on individual stocks. The price dynamics approaching the limit boards are known as the magnet effect. However, the price dynamics after opening price limit hits are not well investigated. Here, we provide a detailed analysis on the price dynamics after the hits of up-limit or down-limit is open based on all A-share stocks traded in the Chinese stock markets. A "W" shape is found in the expected return, which reveals high probability of a continuous price limit hit on the following day. We also find that price dynamics after opening limit hits are dependent on the market trends. The time span of continuously hitting the price limit is found to an influence factor of the expected profit after the limit hit is open. Our analysis provides a better understanding of the price dynamics around the limit boards and contributes potential practical values for investors.

  6. Dawn Mission Education and Public Outreach: Science as Human Endeavor

    Science.gov (United States)

    Cobb, W. H.; Wise, J.; Schmidt, B. E.; Ristvey, J.

    2012-12-01

    Dawn Education and Public Outreach strives to reach diverse learners using multi-disciplinary approaches. In-depth professional development workshops in collaboration with NASA's Discovery Program, MESSENGER and Stardust-NExT missions focusing on STEM initiatives that integrate the arts have met the needs of diverse audiences and received excellent evaluations. Another collaboration on NASA ROSES grant, Small Bodies, Big Concepts, has helped bridge the learning sequence between the upper elementary and middle school, and the middle and high school Dawn curriculum modules. Leveraging the Small Bodies, Big Concepts model, educators experience diverse and developmentally appropriate NASA activities that tell the Dawn story, with teachers' pedagogical skills enriched by strategies drawn from NSTA's Designing Effective Science Instruction. Dawn mission members enrich workshops by offering science presentations to highlight events and emerging data. Teachers' awareness of the process of learning new content is heightened, and they use that experience to deepen their science teaching practice. Activities are sequenced to enhance conceptual understanding of big ideas in space science and Vesta and Ceres and the Dawn Mission 's place within that body of knowledge Other media add depth to Dawn's resources for reaching students. Instrument and ion engine interactives developed with the respective science team leads help audiences engage with the mission payload and the data each instrument collects. The Dawn Dictionary, an offering in both audio as well as written formats, makes key vocabulary accessible to a broader range of students and the interested public. Further, as Dawn E/PO has invited the public to learn about mission objectives as the mission explored asteroid Vesta, new inroads into public presentations such as the Dawn MissionCast tell the story of this extraordinary mission. Asteroid Mapper is the latest, exciting citizen science endeavor designed to invite the

  7. Eyewitness Identification Reforms: Are Suggestiveness-Induced Hits and Guesses True Hits?

    Science.gov (United States)

    Wells, Gary L; Steblay, Nancy K; Dysart, Jennifer E

    2012-05-01

    Research-based reforms for collecting eyewitness identification evidence (e.g., unbiased pre-lineup instructions, double-blind administration) have been proposed by psychologists and adopted in increasing numbers of jurisdictions across the United States. It is well known that reducing rates of mistaken identifications can also reduce accurate identification rates (hits). But the reforms are largely designed to reduce the suggestiveness of the procedures they are meant to replace. Accordingly, we argue that it is misleading to label any hits obtained because of suggestive procedures as "hits" and then saddle reforms with the charge that they reduce the rate of these illegitimate hits. Eyewitness identification evidence should be based solely on the independent memory of the witness, not aided by biased instructions, cues from lineup administrators, or the use of lineup fillers who make the suspect stand out. Failure to call out these hits as being illegitimate can give solace to those who are motivated to preserve the status quo. © The Author(s) 2012.

  8. [Correlation study between obesity and dawn phenomenon in patients with type 2 diabetes].

    Science.gov (United States)

    Guo, Zhenhong; Xu, Jie; Wang, Jingyu; Han, Fei; Zhang, Yi; Yang, X iaoyun; Yang, Shaohua; Chang, Bai; Yang, Juhong; Shan, Chunyan; Chen, Liming; Chang, Baocheng; Xu, Yanguang

    2016-01-01

    To investigate the correlation between the frequency of dawn phenomenon and obesity in patients with type 2 diabetes. This study was conducted in 98 patients with type 2 diabetes admitted to the Metabolic Disease Hospital of Tianjin Medical University from 2011 to 2014. The subjects were divided into 3 groups according to BMI: the normal weight (BMI 18.5-23.9 kg/m(2), n = 30), the overweight(BMI 24-27.9 kg/m(2), n = 33)and the obesity (BMI ≥ 28.0 kg/m(2), n = 35). All participants underwent continuous glucose monitoring for 72 h. Fasting plasma glucose(FPG), insulin and C-peptide were tested. Frequency of dawn phenomenon among the 3 groups was calculated, and the correlations between dawn phenomenon and its related factors were analyzed. The frequency of dawn phenomenon in type 2 diabetes increased with the increase of BMI in the 3 groups (P obesity groups, respectively. The dawn phenomenon was positively correlated with BMI (r = 0.424, P fasting C-peptide (r = 0.254, P 0.05). The dawn phenomenon is closely associated with obesity and insulin resistance. The frequency of dawn phenomenon increases with BMI.

  9. Using Dawn to Observe SEP Events Past 2 AU

    Science.gov (United States)

    Villarreal, M. N.; Russell, C. T.; Prettyman, T. H.

    2017-12-01

    The launch of the STEREO spacecraft provided much insight into the longitudinal and radial distribution of solar energetic particles (SEPs) relative to their origin site. However, almost all of the observations of SEP events have been made exclusively near 1 AU. The Dawn mission, which orbited around Vesta before arriving at Ceres, provides an opportunity to analyze these events at much further distances. Although Dawn's Gamma Ray and Neutron Detector (GRaND) is not optimized for SEP characterization, it is sensitive to protons greater than 4 MeV, making it capable of detecting a solar energetic particle event in its vicinity. Solar energetic particles in this area of the solar system are important as they are believed to cause sputtering at bodies such as Ceres and comets (Villarreal et al., 2017; Wurz et al., 2015). In this study, we use Dawn's GRaND data from 2011-2015 when Dawn was at distances between 2-3 AU. We compare the SEP events seen by Dawn with particle measurements at 1 AU using STEREO, Wind, and ACE to understand how the SEP events evolved past 1 AU.References: Villarreal, M. N., et al. (2017), The dependence of the Cerean exosphere on solar energetic particle events, Astrophys. J. Lett., 838, L8.Wurz, P. et al. (2015), Solar wind sputtering of dust on the surface of 67P/Churyumov-Gerasimenko, A&A, 583, A22.

  10. Dawn Mission Update

    Science.gov (United States)

    Sykes, M. V.; Russell, C. T.; Coradini, A.; Christensen, U.; de Sanctis, M. C.; Feldman, W. C.; Jaumann, R.; Keller, U.; Konopliv, A. S.; McCord, T. B.; McFadden, L. A.; McSween, H. Y.; Mottola, S.; Neukum, G.; Pieters, C. M.; Prettyman, T. H.; Raymond, C. A.; Smith, D. E.; Williams, B. G.; Wise, J.; Zuber, M. T.

    2004-11-01

    Dawn, the ninth Discovery mission, will be the first spacecraft to rendezvous with two solar system bodies, the main belt asteroids Vesta and Ceres. This is made possible by utilizing ion propulsion to reach its targets and to maneuver into (and depart) orbits about these bodies. Vesta and Ceres are two terrestrial protoplanets that have survived since the earliest epoch of the solar system and will provide important insights into planet building processes and their evolution under very different circumstances, with and without water. Dawn carries a double framing camera, a visible and infrared mapping spectrometer, and a gamma ray and neutron detector. At Vesta our studies will include the volcanic emplacement of basalts, its differentiation, the possible exposure of its interior near the south pole. At Ceres our studies will include the role of water in its evolution, hydration processes on its surface, and the possible existence of a subsurface ocean. The mission has passed its critical design review and is scheduled to be launched in June 2006 with arrival at Vesta in 2011 and Ceres in 2015. Operation strategies will be presented. Groundbased observations of Vesta, Ceres, and Vesta family members over broad wavelengths, periods and phases will play an important role in detailed mission planning.

  11. Drug Abuse Warning Network (DAWN-2006)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) is a nationally representative public health surveillance system that has monitored drug related emergency department (ED)...

  12. Drug Abuse Warning Network (DAWN-2005)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) is a nationally representative public health surveillance system that has monitored drug related emergency department (ED)...

  13. Drug Abuse Warning Network (DAWN-2007)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) is a nationally representative public health surveillance system that has monitored drug related emergency department (ED)...

  14. Drug Abuse Warning Network (DAWN-2004)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) is a nationally representative public health surveillance system that has monitored drug related emergency department (ED)...

  15. Drug Abuse Warning Network (DAWN-2009)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) is a nationally representative public health surveillance system that has monitored drug related emergency department (ED)...

  16. Drug Abuse Warning Network (DAWN-2010)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) is a nationally representative public health surveillance system that has monitored drug related emergency department (ED)...

  17. Drug Abuse Warning Network (DAWN-2008)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) is a nationally representative public health surveillance system that has monitored drug related emergency department (ED)...

  18. Drug Abuse Warning Network (DAWN-2011)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) is a nationally representative public health surveillance system that has monitored drug related emergency department (ED)...

  19. A fast online hit verification method for the single ion hit system at GSI

    International Nuclear Information System (INIS)

    Du, G.; Fischer, B.; Barberet, P.; Heiss, M.

    2006-01-01

    For a single ion hit facility built to irradiate specific targets inside biological cells, it is necessary to prove that the ions hit the selected targets reliably because the ion hits usually cannot be seen. That ability is traditionally tested either indirectly by aiming at pre-etched tracks in a nuclear track detector or directly by making the ion tracks inside cells visible using a stain coupled to special proteins produced in response to ion hits. However, both methods are time consuming and hits can be verified only after the experiment. This means that targeting errors in the experiment cannot be corrected during the experiment. Therefore, we have developed a fast online hit verification method that measures the targeting accuracy electronically with a spatial resolution of ±1 μm before cell irradiation takes place. (authors)

  20. A biomechanical comparison in the lower limb and lumbar spine between a hit and drag flick in field hockey.

    Science.gov (United States)

    Ng, Leo; Rosalie, Simon M; Sherry, Dorianne; Loh, Wei Bing; Sjurseth, Andreas M; Iyengar, Shrikant; Wild, Catherine Y

    2018-03-01

    Research has revealed that field hockey drag flickers have greater odds of hip and lumbar injuries compared to non-drag flickers (DF). This study aimed to compare the biomechanics of a field hockey hit and a specialised field hockey drag flick. Eighteen male and seven female specialised hockey DF performed a hit and a drag flick in a motion analysis laboratory with an 18-camera three-dimensional motion analysis system and a calibrated multichannel force platform to examine differences in lower limb and lumbar kinematics and kinetics. Results revealed that drag flicks were performed with more of a forward lunge on the left lower limb resulting in significantly greater left ankle dorsiflexion, knee, hip and lumbar flexion (Pshit. Drag flicks were also performed with significantly greater lateral flexion (P hit. Differences in kinematics lead to greater shear, compression and tensile forces in multiple left lower limb and lumbar joints in the drag flick compared to the hit (P hit may have ramifications with respect to injury in field hockey drag flickers.

  1. Health Information Technology (HIT) Adaptation: Refocusing on the Journey to Successful HIT Implementation.

    Science.gov (United States)

    Yen, Po-Yin; McAlearney, Ann Scheck; Sieck, Cynthia J; Hefner, Jennifer L; Huerta, Timothy R

    2017-09-07

    In past years, policies and regulations required hospitals to implement advanced capabilities of certified electronic health records (EHRs) in order to receive financial incentives. This has led to accelerated implementation of health information technologies (HIT) in health care settings. However, measures commonly used to evaluate the success of HIT implementation, such as HIT adoption, technology acceptance, and clinical quality, fail to account for complex sociotechnical variability across contexts and the different trajectories within organizations because of different implementation plans and timelines. We propose a new focus, HIT adaptation, to illuminate factors that facilitate or hinder the connection between use of the EHR and improved quality of care as well as to explore the trajectory of changes in the HIT implementation journey as it is impacted by frequent system upgrades and optimizations. Future research should develop instruments to evaluate the progress of HIT adaptation in both its longitudinal design and its focus on adaptation progress rather than on one cross-sectional outcome, allowing for more generalizability and knowledge transfer. ©Po-Yin Yen, Ann Scheck McAlearney, Cynthia J Sieck, Jennifer L Hefner, Timothy R Huerta. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 07.09.2017.

  2. The Dawn of Vesta Science

    Science.gov (United States)

    Garner, Charles E.; Rayman, Marc D.; Brophy, John R.; Mikes, Steven C.

    2011-01-01

    The Dawn mission is part of NASA's Discovery Program and has as its goal the scientific exploration of the two most massive main-belt asteroids, Vesta and Ceres. The Dawn spacecraft was launched from the Cape Canaveral Air Force Station on September 27, 2007 on a Delta-II 7925H-9.5 (Delta-II Heavy) rocket that placed the 1218-kg spacecraft onto an Earth-escape trajectory. On-board the spacecraft is an ion propulsion system (IPS) developed at the Jet Propulsion Laboratory which will provide a total ?V of 11.3 km/s for the heliocentric transfer to Vesta, orbit capture at Vesta, transfer between Vesta science orbits, departure and escape from Vesta, heliocentric transfer to Ceres, orbit capture at Ceres, and transfer between Ceres science orbits. Fullpower thrusting from December 2007 through October 2008 was used to successfully target a Mars gravity assist flyby in February 2009 that provided an additional ?V of 2.6 km/s. Deterministic thrusting for the heliocentric transfer to Vesta resumed in June 2009 and concluded with orbit capture at Vesta on July 16, 2011. An additional 210 hours of IPS thrusting was used to enter the first Vesta science orbit, called Survey orbit, on August 3, 2011 at an altitude of approximately 2,735 km. To date the IPS has been operated for 23,621 hours, consumed approximately 252 kg of xenon, and provided a delta-V of approximately 6.7 km/s. The IPS performance characteristics are very close to the expected performance based on analysis and testing performed pre-launch. The only significant issue in over the almost four years of IPS operations in flight was the temporary failure of a valve driver board in the Digital Control and Interface Unit-1 (DCIU-1), resulting in a loss of thrust of approximately 29 hours. Thrusting operations resumed after switching to DCIU-2, and power cycling conducted after orbit capture restored DCIU-1 to full functionality. After about three weeks of Survey orbit operations the IPS will be used to transfer the

  3. Dirty Hits

    OpenAIRE

    Clarke, Louise

    2010-01-01

    Issue 9 of the Saatchi Gallery Magazine: Art&Music is dedicated to Sex. The article Dirty Hits invited a cross-section of contemporary artists and musicians to answer: What makes a dirty hit? As one of the artists invited, I wrote an autobiographical piece to reveal how these fumbling, feral sexual experiences of my childhood landscape, along with irrational superstition and folk law inform my life and underpin my work. The article also included an artwork: Louise Clarke, Sip (2009)

  4. Quantum walks with infinite hitting times

    International Nuclear Information System (INIS)

    Krovi, Hari; Brun, Todd A.

    2006-01-01

    Hitting times are the average time it takes a walk to reach a given final vertex from a given starting vertex. The hitting time for a classical random walk on a connected graph will always be finite. We show that, by contrast, quantum walks can have infinite hitting times for some initial states. We seek criteria to determine if a given walk on a graph will have infinite hitting times, and find a sufficient condition, which for discrete time quantum walks is that the degeneracy of the evolution operator be greater than the degree of the graph. The set of initial states which give an infinite hitting time form a subspace. The phenomenon of infinite hitting times is in general a consequence of the symmetry of the graph and its automorphism group. Using the irreducible representations of the automorphism group, we derive conditions such that quantum walks defined on this graph must have infinite hitting times for some initial states. In the case of the discrete walk, if this condition is satisfied the walk will have infinite hitting times for any choice of a coin operator, and we give a class of graphs with infinite hitting times for any choice of coin. Hitting times are not very well defined for continuous time quantum walks, but we show that the idea of infinite hitting-time walks naturally extends to the continuous time case as well

  5. Improved beam-energy calibration technique for heavy ion accelerators

    International Nuclear Information System (INIS)

    Ferrero, A.M.J.; Garcia, A.; Gil, Salvador

    1989-01-01

    A simple technique for beam energy calibration of heavy-ion accelerators is presented. A thin hydrogenous target was bombarded with 12 C and 19 F, and the energies of the protons knocked out, elastically were measured at several angles using two detectors placed at equal angles on opposite sides of the beam. The use of these two detectors cancels the largest errors due to uncertainties in the angle and position at which the beam hits the target. An application of this energy calibration method to an electrostatic accelerator is described and the calibration constant of the analyzing magnet was obtained with an estimated error of 0.4 (Author) [es

  6. 77 FR 23250 - HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations

    Science.gov (United States)

    2012-04-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations AGENCY: Office of the National Coordinator for Health Information... 2009 mandates that the HIT Standards Committee develop a schedule for the assessment of policy...

  7. 76 FR 25355 - HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations

    Science.gov (United States)

    2011-05-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations AGENCY: Office of the National Coordinator for Health Information... 2009 mandates that the HIT Standards Committee develop a schedule for the assessment of policy...

  8. 78 FR 29134 - HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations

    Science.gov (United States)

    2013-05-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee; Schedule for the Assessment of HIT Policy Committee Recommendations AGENCY: Office of the National Coordinator for Health Information... 2009 mandates that the HIT Standards Committee develop a schedule for the assessment of policy...

  9. Statistical properties and pre-hit dynamics of price limit hits in the Chinese stock markets.

    Science.gov (United States)

    Wan, Yu-Lei; Xie, Wen-Jie; Gu, Gao-Feng; Jiang, Zhi-Qiang; Chen, Wei; Xiong, Xiong; Zhang, Wei; Zhou, Wei-Xing

    2015-01-01

    Price limit trading rules are adopted in some stock markets (especially emerging markets) trying to cool off traders' short-term trading mania on individual stocks and increase market efficiency. Under such a microstructure, stocks may hit their up-limits and down-limits from time to time. However, the behaviors of price limit hits are not well studied partially due to the fact that main stock markets such as the US markets and most European markets do not set price limits. Here, we perform detailed analyses of the high-frequency data of all A-share common stocks traded on the Shanghai Stock Exchange and the Shenzhen Stock Exchange from 2000 to 2011 to investigate the statistical properties of price limit hits and the dynamical evolution of several important financial variables before stock price hits its limits. We compare the properties of up-limit hits and down-limit hits. We also divide the whole period into three bullish periods and three bearish periods to unveil possible differences during bullish and bearish market states. To uncover the impacts of stock capitalization on price limit hits, we partition all stocks into six portfolios according to their capitalizations on different trading days. We find that the price limit trading rule has a cooling-off effect (object to the magnet effect), indicating that the rule takes effect in the Chinese stock markets. We find that price continuation is much more likely to occur than price reversal on the next trading day after a limit-hitting day, especially for down-limit hits, which has potential practical values for market practitioners.

  10. Tracing Cosmic Dawn

    Science.gov (United States)

    Fialkov, Anastasia

    2018-05-01

    Observational effort is on the way to probe the 21-cm of neutral hydrogen from the epochs of Reionization and Cosmic Dawn. Our current poor knowledge of high redshift astrophysics results in a large uncertainty in the theoretically predicted 21-cm signal. A recent parameter study that is highlighted here explores the variety of 21-cm signals resulting from viable astrophysical scenarios. Model-independent relations between the shape of the signal and the underlying astrophysics are discussed. Finally, I briefly note on possible alternative probes of the high redshift Universe, specifically Fast Radio Bursts.

  11. Polarized Redundant-Baseline Calibration for 21 cm Cosmology Without Adding Spectral Structure

    Science.gov (United States)

    Dillon, Joshua S.; Kohn, Saul A.; Parsons, Aaron R.; Aguirre, James E.; Ali, Zaki S.; Bernardi, Gianni; Kern, Nicholas S.; Li, Wenyang; Liu, Adrian; Nunhokee, Chuneeta D.; Pober, Jonathan C.

    2018-04-01

    21 cm cosmology is a promising new probe of the evolution of visible matter in our universe, especially during the poorly-constrained Cosmic Dawn and Epoch of Reionization. However, in order to separate the 21 cm signal from bright astrophysical foregrounds, we need an exquisite understanding of our telescopes so as to avoid adding spectral structure to spectrally-smooth foregrounds. One powerful calibration method relies on repeated simultaneous measurements of the same interferometric baseline to solve for the sky signal and for instrumental parameters simultaneously. However, certain degrees of freedom are not constrained by asserting internal consistency between redundant measurements. In this paper, we review the origin of these degeneracies of redundant-baseline calibration and demonstrate how they can source unwanted spectral structure in our measurement and show how to eliminate that additional, artificial structure. We also generalize redundant calibration to dual-polarization instruments, derive the degeneracy structure, and explore the unique challenges to calibration and preserving spectral smoothness presented by a polarized measurement.

  12. Statistical Properties and Pre-Hit Dynamics of Price Limit Hits in the Chinese Stock Markets

    Science.gov (United States)

    Wan, Yu-Lei; Xie, Wen-Jie; Gu, Gao-Feng; Jiang, Zhi-Qiang; Chen, Wei; Xiong, Xiong; Zhang, Wei; Zhou, Wei-Xing

    2015-01-01

    Price limit trading rules are adopted in some stock markets (especially emerging markets) trying to cool off traders’ short-term trading mania on individual stocks and increase market efficiency. Under such a microstructure, stocks may hit their up-limits and down-limits from time to time. However, the behaviors of price limit hits are not well studied partially due to the fact that main stock markets such as the US markets and most European markets do not set price limits. Here, we perform detailed analyses of the high-frequency data of all A-share common stocks traded on the Shanghai Stock Exchange and the Shenzhen Stock Exchange from 2000 to 2011 to investigate the statistical properties of price limit hits and the dynamical evolution of several important financial variables before stock price hits its limits. We compare the properties of up-limit hits and down-limit hits. We also divide the whole period into three bullish periods and three bearish periods to unveil possible differences during bullish and bearish market states. To uncover the impacts of stock capitalization on price limit hits, we partition all stocks into six portfolios according to their capitalizations on different trading days. We find that the price limit trading rule has a cooling-off effect (object to the magnet effect), indicating that the rule takes effect in the Chinese stock markets. We find that price continuation is much more likely to occur than price reversal on the next trading day after a limit-hitting day, especially for down-limit hits, which has potential practical values for market practitioners. PMID:25874716

  13. Developing Health Information Technology (HIT) Programs and HIT Curriculum: The Southern Polytechnic State University Experience

    Science.gov (United States)

    Zhang, Chi; Reichgelt, Han; Rutherfoord, Rebecca H.; Wang, Andy Ju An

    2014-01-01

    Health Information Technology (HIT) professionals are in increasing demand as healthcare providers need help in the adoption and meaningful use of Electronic Health Record (EHR) systems while the HIT industry needs workforce skilled in HIT and EHR development. To respond to this increasing demand, the School of Computing and Software Engineering…

  14. Moon Search Algorithms for NASA's Dawn Mission to Asteroid Vesta

    Science.gov (United States)

    Memarsadeghi, Nargess; Mcfadden, Lucy A.; Skillman, David R.; McLean, Brian; Mutchler, Max; Carsenty, Uri; Palmer, Eric E.

    2012-01-01

    A moon or natural satellite is a celestial body that orbits a planetary body such as a planet, dwarf planet, or an asteroid. Scientists seek understanding the origin and evolution of our solar system by studying moons of these bodies. Additionally, searches for satellites of planetary bodies can be important to protect the safety of a spacecraft as it approaches or orbits a planetary body. If a satellite of a celestial body is found, the mass of that body can also be calculated once its orbit is determined. Ensuring the Dawn spacecraft's safety on its mission to the asteroid Vesta primarily motivated the work of Dawn's Satellite Working Group (SWG) in summer of 2011. Dawn mission scientists and engineers utilized various computational tools and techniques for Vesta's satellite search. The objectives of this paper are to 1) introduce the natural satellite search problem, 2) present the computational challenges, approaches, and tools used when addressing this problem, and 3) describe applications of various image processing and computational algorithms for performing satellite searches to the electronic imaging and computer science community. Furthermore, we hope that this communication would enable Dawn mission scientists to improve their satellite search algorithms and tools and be better prepared for performing the same investigation in 2015, when the spacecraft is scheduled to approach and orbit the dwarf planet Ceres.

  15. Multiple-hit parameter estimation in monolithic detectors.

    Science.gov (United States)

    Hunter, William C J; Barrett, Harrison H; Lewellen, Tom K; Miyaoka, Robert S

    2013-02-01

    We examine a maximum-a-posteriori method for estimating the primary interaction position of gamma rays with multiple interaction sites (hits) in a monolithic detector. In assessing the performance of a multiple-hit estimator over that of a conventional one-hit estimator, we consider a few different detector and readout configurations of a 50-mm-wide square cerium-doped lutetium oxyorthosilicate block. For this study, we use simulated data from SCOUT, a Monte-Carlo tool for photon tracking and modeling scintillation- camera output. With this tool, we determine estimate bias and variance for a multiple-hit estimator and compare these with similar metrics for a one-hit maximum-likelihood estimator, which assumes full energy deposition in one hit. We also examine the effect of event filtering on these metrics; for this purpose, we use a likelihood threshold to reject signals that are not likely to have been produced under the assumed likelihood model. Depending on detector design, we observe a 1%-12% improvement of intrinsic resolution for a 1-or-2-hit estimator as compared with a 1-hit estimator. We also observe improved differentiation of photopeak events using a 1-or-2-hit estimator as compared with the 1-hit estimator; more than 6% of photopeak events that were rejected by likelihood filtering for the 1-hit estimator were accurately identified as photopeak events and positioned without loss of resolution by a 1-or-2-hit estimator; for PET, this equates to at least a 12% improvement in coincidence-detection efficiency with likelihood filtering applied.

  16. Dawn song in natural and artificial continuous day: Light pollution affects songbirds at high latitudes.

    Science.gov (United States)

    Derryberry, Elizabeth P

    2017-10-01

    In Focus: Da Silva, A., & Kempenaers, B. (2017). Singing from North to South: Latitudinal variation in timing of dawn singing under natural and artificial light conditions. Journal of Animal Ecology, 86, 1286-1297. doi: 10.1111/1365-2656.12739 Satellite images of the world at night show bright dots connected by glowing lines crisscrossing the globe. As these connect-the-dots become brighter and expand into more and more remote regions, much of the flora and fauna of the world are experiencing evolutionarily unprecedented levels of light at night. Light cues are essential to most physiological and behavioural processes, and so the need to measure the effects of light pollution on these processes is critical. In this issue, Da Silva and Kempenaers take on this task using an important reproductive behaviour in songbirds-dawn song. The geographic, temporal and taxonomic breadth of sampling in this study allows for a close examination of a potentially complex interaction between light pollution and natural variation in the behaviour of dawn singing across latitude, season and species. Their extensive dataset highlights complexity in how songbirds respond to light pollution. Although light pollution has a strong effect on the timing of dawn song, not all songbirds respond the same way to light pollution, and the effects of light pollution vary with changes in natural light levels. Early dawn singers show more flexibility in the timing of dawn song across the season and across latitudes than late dawn singers, and also appear less affected by light pollution at high latitudes than are late dawn singers. These findings suggest that not all songbirds are responding to artificial continuous daylight as they do to natural continuous daylight, highlighting the general need to measure the fitness effects of light pollution. © 2017 The Author. Journal of Animal Ecology © 2017 British Ecological Society.

  17. Ceres' Geophysical Evolution Inferred from Dawn Data

    Science.gov (United States)

    Castillo-Rogez, Julie; Bowling, Timothy; Ermakov, Anton I.; Fu, Roger; Park, Ryan; Raymond, Carol; De Sanctis, Maria Cristina; Ammannito, Eleonora; Ruesch, Ottaviano; Prettyman, Thomas H.; Y McSween, Harry; Toplis, Michael J.; Russell, Christopher T.; Dawn Team

    2016-10-01

    If Ceres formed as an ice-rich body, as suggested by its low density and the detection of ammoniated phyllosilicates [1], then it should have differentiated an ice-dominated shell, analogous to large icy satellites [2]. Instead, Dawn observations revealed an enrichment of Ceres' shell in strong materials, either a rocky component and/or salts and gas hydrates [3, 4, 5, 6]. We have explored several scenarios for the emplacement of Ceres' surface. Endogenic processes cannot account for its overall homogeneity. Instead we suggest that Ceres differentiated an icy shell upon freezing of its early ocean that was removed as a consequence of frequent exposure by impacting after the dwarf planet migrated from a cold accretional environment to the warmer outer main belt (or when the solar nebula dissipated, if Ceres formed in situ). This scenario implies that Ceres' current surface represents the interface between the original ice shell and the top of the frozen ocean, a region that is extremely rich chemistry-wise, as illustrated by the mineralogical observations returned by Dawn [7]. Thermal modeling shows that the shell could remain warm over the long term and offer a setting for the generation of brines that may be responsible for the emplacement of Ahuna Mons [8] and Occator's bright spots [7] on an otherwise homogeneous surface [9]. An important implication is that Ceres' surface offers an analog for better understanding the deep interior and chemical evolution of large ice-rich bodies.References: [1] De Sanctis et al., Nature, 2015; [2] McCord and Sotin, Journal of Geophysical Research, 2005; [3] Park et al., Nature, 2016 (in press); [4] Hiesinger et al., Science (submitted); [5] Bland et al., Nature Geoscience, 2016 (in press); [6] Fu et al., AGU Fall Meeting, 2015 [7] De Sanctis et al., Nature, 2016 (in press); [8] Ruesch et al., Science, in revision; [9] Ammannito et al., Science, 2016 (accepted).Acknowledgements: Part of this work is being carried out at the Jet

  18. The SVT Hit Buffer

    International Nuclear Information System (INIS)

    Belforte, S.; Dell'Orso, M.; Donati, S.

    1996-01-01

    The Hit Buffer is part of the Silicon Vertex Tracker, a trigger processor dedicated to the reconstruction of particle trajectories in the Silicon Vertex Detector and the Central Tracking Chamber of the Collider Detector at Fermilab. The Hit Buffer is a high speed data-traffic node, where thousands of words are received in arbitrary order and simultaneously organized in an internal structured data base, to be later promptly retrieved and delivered in response to specific requests. The Hit Buffer is capable of processing data at a rate of 25 MHz, thanks to the use of special fast devices like Cache-Tag RAMs and high performance Erasable Programmable Logic Devices from the XILINX XC7300 family

  19. Heparin-independent, PF4-dependent binding of HIT antibodies to platelets: implications for HIT pathogenesis.

    Science.gov (United States)

    Padmanabhan, Anand; Jones, Curtis G; Bougie, Daniel W; Curtis, Brian R; McFarland, Janice G; Wang, Demin; Aster, Richard H

    2015-01-01

    Antibodies specific for platelet factor 4 (PF4)/heparin complexes are the hallmark of heparin-induced thrombocytopenia and thrombosis (HIT), but many antibody-positive patients have normal platelet counts. The basis for this is not fully understood, but it is believed that antibodies testing positive in the serotonin release assay (SRA) are the most likely to cause disease. We addressed this issue by characterizing PF4-dependent binding of HIT antibodies to intact platelets and found that most antibodies testing positive in the SRA, but none of those testing negative, bind to and activate platelets when PF4 is present without any requirement for heparin (P HIT antibodies recognize PF4 in a complex with heparin, only a subset of these antibodies recognize more subtle epitopes induced in PF4 when it binds to CS, the major platelet glycosaminoglycan. Antibodies having this property could explain "delayed HIT" seen in some individuals after discontinuation of heparin and the high risk for thrombosis that persists for weeks in patients recovered from HIT. © 2015 by The American Society of Hematology.

  20. Drug Abuse Warning Network US (DAWN-NS-1994)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) survey is designed to capture data on emergency department (ED) episodes that are induced by or related to the use of an...

  1. Drug Abuse Warning Network US (DAWN-NS-1997)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Abuse Warning Network (DAWN) survey is designed to capture data on emergency department (ED) episodes that are induced by or related to the use of an...

  2. How I treat double-hit lymphoma.

    Science.gov (United States)

    Friedberg, Jonathan W

    2017-08-03

    The 2016 revision of the World Health Organization (WHO) classification for lymphoma has included a new category of lymphoma, separate from diffuse large B-cell lymphoma, termed high-grade B-cell lymphoma with translocations involving myc and bcl-2 or bcl-6 . These lymphomas, which occur in hit lymphomas (or triple-hit lymphomas if all 3 rearrangements are present). It is important to differentiate these lymphomas from the larger group of double-expressor lymphomas, which have increased expression of MYC and BCL-2 and/or BCL-6 by immunohistochemistry, by using variable cutoff percentages to define positivity. Patients with double-hit lymphomas have a poor prognosis when treated with standard chemoimmunotherapy and have increased risk of central nervous system involvement and progression. Double-hit lymphomas may arise as a consequence of the transformation of the underlying indolent lymphoma. There are no published prospective trials in double-hit lymphoma, however retrospective studies strongly suggest that aggressive induction regimens may confer a superior outcome. In this article, I review my approach to the evaluation and treatment of double-hit lymphoma, with an eye toward future clinical trials incorporating rational targeted agents into the therapeutic armamentarium. © 2017 by The American Society of Hematology.

  3. Statistics of hits to bone cell nuclei

    International Nuclear Information System (INIS)

    Kruglikov, I.L.; Polig, E.; Jee, W.S.S.

    1993-01-01

    The statistics of hits to the nuclei of bone cells irradiated from alpha sources labeling bone tissue is described. It is shown that the law of remodeling of a bone structural unit (BSU), which describes the distribution of quiescence periodes of this unit, affects the statistics of hits. It the irradiation of bone cells occurs during the whole cell cycle, the mean number of hits is independent of the law of remodeling. In this case the variance of hits has the minimum value for constant quiescence periods of BSUs (deterministic remodeling) and the maximum value for exponentially distributed quiescence periods (random remodeling). For the first generation of bone cells, i.e. for the cells which existed at the moment of the uptake of the nuclide, the mean number of hits depends on the law of remodeling. For random remodeling the mean number is equal to the mean value for the complete remodeling cycle. For deterministic remodeling the mean is only half this value. For the first generation of bone cells, changing the law of remodeling from random to deterministic increases the probability of no hits to the nuclei of bone cells. For the same mean value of hits, the difference does not exceed 13.3% of the total number of cells. For the subsequent generations of bone cells, such a change of the law of remodeling decreases the probability of no hits up to 20.4% of the total number of cells. (orig.)

  4. Recent Improvements in the SHIELD-HIT Code

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Lühr, Armin Christian; Herrmann, Rochus

    2012-01-01

    Purpose: The SHIELD-HIT Monte Carlo particle transport code has previously been used to study a wide range of problems for heavy-ion treatment and has been benchmarked extensively against other Monte Carlo codes and experimental data. Here, an improved version of SHIELD-HIT is developed concentra......Purpose: The SHIELD-HIT Monte Carlo particle transport code has previously been used to study a wide range of problems for heavy-ion treatment and has been benchmarked extensively against other Monte Carlo codes and experimental data. Here, an improved version of SHIELD-HIT is developed...

  5. STAR barrel electromagnetic calorimeter absolute calibration using 'minimum ionizing particles' from collisions at RHIC

    International Nuclear Information System (INIS)

    Cormier, T.M.; Pavlinov, A.I.; Rykov, M.V.; Rykov, V.L.; Shestermanov, K.E.

    2002-01-01

    The procedure for the STAR Barrel Electromagnetic Calorimeter (BEMC) absolute calibrations, using penetrating charged particle hits (MIP-hits) from physics events at RHIC, is presented. Its systematic and statistical errors are evaluated. It is shown that, using this technique, the equalization and transfer of the absolute scale from the test beam can be done to a percent level accuracy in a reasonable amount of time for the entire STAR BEMC. MIP-hits would also be an effective tool for continuously monitoring the variations of the BEMC tower's gains, virtually without interference to STAR's main physics program. The method does not rely on simulations for anything other than geometric and some other small corrections, and also for estimations of the systematic errors. It directly transfers measured test beam responses to operations at RHIC

  6. Nedley Depression Hit Hypothesis

    OpenAIRE

    Nedley, Neil; Ramirez, Francisco E.

    2014-01-01

    Depression is often diagnosed using the Diagnostic and Statistical Manual of Mental Disorders Fifth Edition (DSM-5) criteria. We propose how certain lifestyle choices and non-modifiable factors can predict the development of depression. We identified 10 cause categories (hits or ?blows? to the brain) and theorize that four or more active hits could trigger a depression episode. Methods. A sample of 4271 participants from our community-based program (70% female; ages 17-94 years) was assessed ...

  7. Current insights into the laboratory diagnosis of HIT.

    Science.gov (United States)

    Bakchoul, T; Zöllner, H; Greinacher, A

    2014-06-01

    Heparin-induced thrombocytopenia (HIT) is an adverse drug reaction and prothrombotic disorder caused by immunization against platelet factor 4 (PF4) after complex formation with heparin or other polyanions. After antibody binding to PF4/heparin complexes, HIT antibodies are capable of intravascular platelet activation by cross-linking Fc gamma receptor IIa (FcγRIIa) on the platelet surface leading to a platelet count decrease and/or thrombosis. In contrast to most other immune-mediated disorders, the currently available laboratory tests for anti-PF4/heparin antibodies show a high sensitivity also for clinically irrelevant antibodies. This makes the diagnosis of HIT challenging and bears the risk to substantially overdiagnose HIT. The strength of the antigen assays for HIT is in ruling out HIT when the test is negative. Functional assays have a higher specificity for clinically relevant antibodies, but they are restricted to specialized laboratories. Currently, a Bayesian approach combining the clinical likelihood estimation for HIT with laboratory tests is the most appropriate approach to diagnose HIT. In this review, we give an overview on currently available diagnostic procedures and discuss their limitations. © 2014 John Wiley & Sons Ltd.

  8. Cosmological Structure Formation: From Dawn till Dusk

    DEFF Research Database (Denmark)

    Heneka, Caroline Samantha

    Cosmology has entered an era where a plethora data is available on structure formation to constrain astrophysics and underlying cosmology. This thesis strives to both investigate new observables and modeling of the Epoch of Reionization, as well as to constrain dark energy phenomenology with mass......Cosmology has entered an era where a plethora data is available on structure formation to constrain astrophysics and underlying cosmology. This thesis strives to both investigate new observables and modeling of the Epoch of Reionization, as well as to constrain dark energy phenomenology...... with massive galaxy clusters, traveling from the dawn of structure formation, when the first galaxies appear, to its dusk, when a representative part of the mass in the Universe is settled in massive structures. This hunt for accurate constraints on cosmology is complemented with the demonstration of novel...... Bayesian statistical tools and kinematical constraints on dark energy. Starting at the dawn of structure formation, we study emission line fluctuations, employing semi-numerical simulations of cosmological volumes of their line emission, in order to cross-correlate fluctuations in brightness. This cross...

  9. The highest-ranking rooster has priority to announce the break of dawn

    OpenAIRE

    Shimmura, Tsuyoshi; Ohashi, Shosei; Yoshimura, Takashi

    2015-01-01

    The ?cock-a-doodle-doo? crowing of roosters, which symbolizes the break of dawn in many cultures, is controlled by the circadian clock. When one rooster announces the break of dawn, others in the vicinity immediately follow. Chickens are highly social animals, and they develop a linear and fixed hierarchy in small groups. We found that when chickens were housed in small groups, the top-ranking rooster determined the timing of predawn crowing. Specifically, the top-ranking rooster always start...

  10. Constructive Technology Assessment for HIT development

    DEFF Research Database (Denmark)

    Høstgaard, Anna Marie Balling; Bertelsen, Pernille; Petersen, Lone Stub

    2013-01-01

    Experience and time has shown a need for new evaluation methods for evaluating Health Information Technology (HIT), as summative evaluation methods fail to accommodate the rapid and constant changes in HIT over time and to involve end-users, which has been recognized as an important success facto...... during all the phases in the process. Thereby anumber of problems were prevented to occur later on.Thus, the CTA method and its framework are useful for evaluators and project-management in order to facilitate and support successful HIT development....

  11. Natural entrainment without dawn and dusk : The case of the European ground squirrel (Spermophilus citellus)

    NARCIS (Netherlands)

    Hut, RA; van Oort, BEH; Daan, S; Oort, Bob E.H. van

    Observational data collected in the field and in enclosures show that diurnal, burrow-dwelling European ground squirrels (Spermophilus citellus) never were above ground during twilight at dawn or at dusk. The animals emerged on average 4.02 h (SD = 0.45) after civil twilight at dawn and retreated in

  12. Simplified validation of borderline hits of database searches

    OpenAIRE

    Thomas, Henrik; Shevchenko, Andrej

    2008-01-01

    Along with unequivocal hits produced by matching multiple MS/MS spectra to database sequences, LC-MS/MS analysis often yields a large number of hits of borderline statistical confidence. To simplify their validation, we propose to use rapid de novo interpretation of all acquired MS/MS spectra and, with the help of a simple software tool, display the candidate sequences together with each database search hit. We demonstrate that comparing hit database sequences and independent de novo interpre...

  13. 4 Vesta in Color: High Resolution Mapping from Dawn Framing Camera Images

    Science.gov (United States)

    Reddy, V.; LeCorre, L.; Nathues, A.; Sierks, H.; Christensen, U.; Hoffmann, M.; Schroeder, S. E.; Vincent, J. B.; McSween, H. Y.; Denevi, B. W.; hide

    2011-01-01

    Rotational surface variations on asteroid 4 Vesta have been known from ground-based and HST observations, and they have been interpreted as evidence of compositional diversity. NASA s Dawn mission entered orbit around Vesta on July 16, 2011 for a year-long global characterization. The framing cameras (FC) onboard the Dawn spacecraft will image the asteroid in one clear (broad) and seven narrow band filters covering the wavelength range between 0.4-1.0 microns. We present color mapping results from the Dawn FC observations of Vesta obtained during Survey orbit (approx.3000 km) and High-Altitude Mapping Orbit (HAMO) (approx.950 km). Our aim is to create global color maps of Vesta using multi spectral FC images to identify the spatial extent of compositional units and link them with other available data sets to extract the basic mineralogy. While the VIR spectrometer onboard Dawn has higher spectral resolution (864 channels) allowing precise mineralogical assessment of Vesta s surface, the FC has three times higher spatial resolution in any given orbital phase. In an effort to extract maximum information from FC data we have developed algorithms using laboratory spectra of pyroxenes and HED meteorites to derive parameters associated with the 1-micron absorption band wing. These parameters will help map the global distribution of compositionally related units on Vesta s surface. Interpretation of these units will involve the integration of FC and VIR data.

  14. 78 FR 29135 - HIT Standards Committee Advisory Meeting

    Science.gov (United States)

    2013-05-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting AGENCY: Office of...: HIT Standards Committee. General Function of the Committee: To provide recommendations to the National... Federal Health IT Strategic Plan, and in accordance with policies developed by the HIT Policy Committee...

  15. Reduction of multiple hits in atom probe tomography

    International Nuclear Information System (INIS)

    Thuvander, Mattias; Kvist, Anders; Johnson, Lars J.S.; Weidow, Jonathan; Andrén, Hans-Olof

    2013-01-01

    The accuracy of compositional measurements using atom probe tomography is often reduced because some ions are not recorded when several ions hit the detector in close proximity to each other and within a very short time span. In some cases, for example in analysis of carbides, the multiple hits result in a preferential loss of certain elements, namely those elements that frequently field evaporate in bursts or as dissociating molecules. In this paper a method of reducing the effect of multiple hits is explored. A fine metal grid was mounted a few millimeters behind the local electrode, effectively functioning as a filter. This resulted in a decrease in the overall detection efficiency, from 37% to about 5%, but also in a decrease in the fraction of multiple hits. In an analysis of tungsten carbide the fraction of ions originating from multiple hits decreased from 46% to 10%. As a result, the measured carbon concentration increased from 48.2 at%to 49.8 at%, very close to the expected 50.0 at%. The characteristics of the multiple hits were compared for analyses with and without the grid filter. - Highlights: ► APT experiments have been performed with a reduced amount of multiple hits. ► The multiple hits were reduced by placing a grid behind the electrode. ► This resulted in improved carbon measurement of WC

  16. 42 CFR 495.340 - As-needed HIT PAPD update and as-needed HIT IAPD update requirements.

    Science.gov (United States)

    2010-10-01

    ... limited to any of the following: (a) A projected cost increase of $100,000 or more. (b) A schedule... implementation approach, or scope of activities beyond that approved in the HIT planning advance planning document or the HIT implementation advance planning document. (d) A change in implementation concept or a...

  17. On the Hitting Probability of Max-Stable Processes

    OpenAIRE

    Hofmann, Martin

    2012-01-01

    The probability that a max-stable process {\\eta} in C[0, 1] with identical marginal distribution function F hits x \\in R with 0 < F (x) < 1 is the hitting probability of x. We show that the hitting probability is always positive, unless the components of {\\eta} are completely dependent. Moreover, we consider the event that the paths of standard MSP hit some x \\in R twice and we give a sufficient condition for a positive probability of this event.

  18. Implementation of a rapid HIT immunoassay at a university hospital - Retrospective analysis of HIT laboratory orders in patients with thrombocytopenia.

    Science.gov (United States)

    Black, Anne; Heimerl, Susanne; Oertli, Linnéa; Wilczek, Wolf; Greinacher, Andreas; Spannagl, Michael; Herr, Wolfgang; Hart, Christina

    2017-10-01

    Heparin-induced thrombocytopenia (HIT) is a rare cause of thrombocytopenia and a potentially life-threatening adverse drug reaction. Clinical overdiagnosis of HIT results in costly laboratory tests and anticoagulation. Criteria and algorithms for diagnosis are established, but their translation into clinical practice is still challenging. In a retrospective approach we studied all HIT related laboratory test requests within four years and evaluated data before (1st period, 24month) and after (2nd period, 24month) replacing particle gel immunoassay (PaGIA) and enzyme-linked immunosorbent assay (ELISA) by a chemiluminescent immunoassay (CLIA). HIT was confirmed by heparin-induced platelet activation (HIPA) test. Clinical pretest probability for HIT using an implemented simplified 4Ts score and platelet count were evaluated. Costs for laboratory tests and alternative anticoagulation were calculated. In 1850 patients with suspected HIT, 2327 laboratory orders were performed. In 87.2% of these orders an intermediate/high simplified 4Ts score was found. Thrombocytopenia was present in 87.1%. After replacing PaGIA and ELISA by CLIA the number of immunological and functional laboratory tests was reduced by 38.2%. The number of positive HIT immunoassays declined from 22.6% to 6.0%, while the number of positive HIPA tests among positive immunological tests increased by 19%. Altogether, acute HIT was confirmed in 59 patients. A decline in the use of alternative anticoagulants was observed in the 2nd period. Our study shows that in a university hospital setting HIT is well-known, but diagnosis requires a precise laboratory confirmation. Replacing PaGIA and ELISA by CLIA did not influence laboratory order behavior but results in reduced overall costs for laboratory diagnostics and alternative anticoagulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Dawn chorus variation in East-Asian tropical montane forest birds and its ecological and morphological correlates

    NARCIS (Netherlands)

    Chen, W.-M.; Lee, Y.-F.; Tsai, C.-F.; Yao, C.-T.; Chen, Y.-H.; Li, S.-H.; Kuo, Y.-M.

    2015-01-01

    Many birds in breeding seasons engage in vigorous dawn singing that often turns to a prominent chorus. We examined dawn chorus variation of avian assemblages in a tropical montane forest in Taiwan and tested the hypothesis that onset sequence is affected by eye sizes, foraging heights, and diet of

  20. Paradigms and Paradoxes: Dawn at Vesta

    Science.gov (United States)

    Raymond, Carol; Russell, Christopher; Mittlefehldt, David

    2014-05-01

    While confirming the paradigm of Vesta as the parent body of the HED meteorites, measurements by Dawn have discovered many unexpected aspects of the vestan surface. First, an olivine layer was not found in the bottom of the large basin near the south pole of Vesta where excavation of the mantle was thought to have occurred. In fact, while patches of olivine have been found in the north, it is rare on the surface. Secondly, while Vesta has little gravity and appears to have completely differentiated, it is not completely dry. Morphological evidence from the walls and floors of some craters suggest transient fluid flows and pits formed by devolatization, implying a substantial amount of accessible water. The question is, did this water derive from internal or external sources? Thirdly, transport of material to the surface of Vesta from elsewhere in the asteroid belt appears as dark material buried near the top of the regolith of Vesta. This may have arrived in a single large impact and been spread around the surface and buried, later to be re-excavated. However, this is not the only scenario possible for the source of this material. Meteoritical evidence from howardites shows that debris from multiple types of impactors are present in the vestan regolith. In short, Dawn's observations of Vesta have been both reassuring but unsettling at the same time.

  1. [Role of growth hormone in the pathogenesis of dawn phenomenon in IDDM].

    Science.gov (United States)

    Mimura, A; Kageyama, S; Itoh, K; Miura, J; Kurata, H; Yokoyama, J; Ikeda, Y

    1992-06-20

    The early morning hyperglycemia of diabetic patients has been commonly referred to as the "dawn phenomenon". Recently the nocturnal surges of growth hormone (GH) have been suggested as an important factor in the pathogenesis of the dawn phenomenon. In order to reassess the role of the nocturnal GH secretion in the dawn phenomenon, seven C-peptide negative diabetic patients were studied during 48hr-feedback control using a closed-loop insulin infusion device (Biostator). They received oral sleeping medication only on the first night (control) and sleeping medication with anticholinergic agent (pirenzepine 75mg) on the second night, and blood glucose, insulin requirements, GH and cortisol concentrations during 0000hr and 0700hr were measured. The peak of sleep-induced GH secretions was markedly suppressed by pirenzepine in comparison with the control night (19.8 +/- 3.7 vs. 3.0 +/- 1.2ng/ml; p less than 0.05). Insulin requirements during 0500hr and 0700hr were suppressed significantly by pirenzepine (3.0 +/- 0.2 vs. 2.0 +/- 0.2U/2hr; p less than 0.05). Insulin infusion ratio, i.e. insulin requirements during 0500hr and 0700hr divided by those during 0000hr and 0200hr, was decreased by pirenzepine (2.2 +/- 0.3 vs. 1.5 +/- 0.2; p less than 0.05). There were no significant differences in blood glucose and cortisol concentrations whether or not the anticholinergic agent was given. In conclusion, these results have shown that an anticholinergic agent may be useful in the management of insulin-treated patients with marked dawn phenomenon.

  2. Novel HIT antibody detection method using Sonoclot® coagulation analyzer.

    Science.gov (United States)

    Wanaka, Keiko; Asada, Reiko; Miyashita, Kumiko; Kaneko, Makoto; Endo, Hirokazu; Yatomi, Yutaka

    2015-01-01

    Since heparin-induced thrombocytopenia (HIT), caused by the generation of antibodies against platelet factor 4 (PF4)/heparin complexes (HIT antibodies), may induce serious complications due to thrombosis, a prompt diagnosis is desirable. Functional tests with platelet activation to detect HIT antibodies are useful for diagnosis of HIT, in particular (14)C-selotonin release assay (SRA). However, they are complicated and so can be performed only in limited laboratories. We tested if a blood coagulation test using Sonoclot® analyzer can serve for the detection of HIT antibodies. A murine monoclonal antibody (HIT-MoAb) against PF4/heparin complexes was used as an alternative to human HIT antibodies. To the mixture of HIT-MoAb and heparin (0.5 U/mL, final), whole blood obtained from a healthy volunteer was added, and then the activated clotting time (ACT), clot rate (CR), and area under the curve (AUC) were measured with Sonoclot® analyzer for 30minutes. The HIT-MoAb (30 to 100μg/mL, final) concentration dependently suppressed the anticoagulation activity (prolongation of ACT and decrease of CR and AUC) of heparin. The suppression of anticoagulation effect of heparin by HIT-MoAb was demonstrated by measurements using Sonoclot® analyzer. This method may provide a new tool for screening of HIT antibodies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. A quasi-online distributed data processing on WAN: the ATLAS muon calibration system

    CERN Document Server

    De Salvo, A; The ATLAS collaboration

    2013-01-01

    In the Atlas experiment, the calibration of the precision tracking chambers of the muon detector is very demanding, since the rate of muon tracks required to get a complete calibration in homogeneous conditions and to feed prompt reconstruction with fresh constants is very high (several hundreds Hz for 8-10 hours runs). The calculation of calibration constants is highly CPU consuming. In order to fulfill the requirement of completing the cycle and having the final constants available within 24 hours, distributed resources at Tier-2 centers have been allocated. The best place to get muon tracks suitable for detector calibration is the second level trigger, where the pre-selection of data sitting in a limited region by the first level trigger via the Region of Interest mechanism allows selecting all the hits from a single track in a limited region of the detector. Online data extraction allows calibration data collection without performing special runs. Small event pseudo-fragments (about 0.5 kB) built at the m...

  4. The validation of Huffaz Intelligence Test (HIT)

    Science.gov (United States)

    Rahim, Mohd Azrin Mohammad; Ahmad, Tahir; Awang, Siti Rahmah; Safar, Ajmain

    2017-08-01

    In general, a hafiz who can memorize the Quran has many specialties especially in respect to their academic performances. In this study, the theory of multiple intelligences introduced by Howard Gardner is embedded in a developed psychometric instrument, namely Huffaz Intelligence Test (HIT). This paper presents the validation and the reliability of HIT of some tahfiz students in Malaysia Islamic schools. A pilot study was conducted involving 87 huffaz who were randomly selected to answer the items in HIT. The analysis method used includes Partial Least Square (PLS) on reliability, convergence and discriminant validation. The study has validated nine intelligences. The findings also indicated that the composite reliabilities for the nine types of intelligences are greater than 0.8. Thus, the HIT is a valid and reliable instrument to measure the multiple intelligences among huffaz.

  5. MYC/BCL2/BCL6 triple hit lymphoma: a study of 40 patients with a comparison to MYC/BCL2 and MYC/BCL6 double hit lymphomas.

    Science.gov (United States)

    Huang, Wenting; Medeiros, L Jeffrey; Lin, Pei; Wang, Wei; Tang, Guilin; Khoury, Joseph; Konoplev, Sergej; Yin, C Cameron; Xu, Jie; Oki, Yasuhiro; Li, Shaoying

    2018-05-21

    High-grade B-cell lymphomas with MYC, BCL2, and BCL6 rearrangements (triple hit lymphoma) are uncommon. We studied the clinicopathologic features of 40 patients with triple hit lymphoma and compared them to 157 patients with MYC/BCL2 double hit lymphoma and 13 patients with MYC/BCL6 double hit lymphoma. The triple hit lymphoma group included 25 men and 15 women with a median age of 61 years (range, 34-85). Nine patients had a history of B-cell lymphoma. Histologically, 23 (58%) cases were diffuse large B-cell lymphoma and 17 cases had features of B-cell lymphoma, unclassifiable, with features intermediate between diffuse large B-cell lymphoma and Burkitt lymphoma. Most cases of triple hit lymphoma were positive for CD10 (100%), BCL2 (95%), BCL6 (82%), MYC (74%), and 71% with MYC and BCL2 coexpression. P53 was overexpressed in 29% of triple hit lymphoma cases. The clinicopathological features of triple hit lymphoma patients were similar to patients with MYC/BCL2 and MYC/BCL6 double hit lymphoma, except that triple hit lymphoma cases were more often CD10 positive compared with MYC/BCL6 double hit lymphoma (p hit lymphoma and double hit lymphoma and overall survival in triple hit lymphoma patients was 17.6 months, similar to the overall survival of patients with double hit lymphoma (p = 0.67). Patients with triple hit lymphoma showing P53 overexpression had significantly worse overall survival compared with those without P53 overexpression (p = 0.04). On the other hand, double expressor status and prior history of B-cell lymphoma did not correlate with overall survival. In conclusion, most patients with triple hit lymphoma have an aggressive clinical course and poor prognosis and these tumors have a germinal center B-cell immunophenotype, similar to patients with double hit lymphomas. P53 expression is a poor prognostic factor in patients with triple hit lymphoma.

  6. High-resolution Ceres Low Altitude Mapping Orbit Atlas derived from Dawn Framing Camera images

    Science.gov (United States)

    Roatsch, Th.; Kersten, E.; Matz, K.-D.; Preusker, F.; Scholten, F.; Jaumann, R.; Raymond, C. A.; Russell, C. T.

    2017-06-01

    The Dawn spacecraft Framing Camera (FC) acquired over 31,300 clear filter images of Ceres with a resolution of about 35 m/pxl during the eleven cycles in the Low Altitude Mapping Orbit (LAMO) phase between December 16 2015 and August 8 2016. We ortho-rectified the images from the first four cycles and produced a global, high-resolution, uncontrolled photomosaic of Ceres. This global mosaic is the basis for a high-resolution Ceres atlas that consists of 62 tiles mapped at a scale of 1:250,000. The nomenclature used in this atlas was proposed by the Dawn team and was approved by the International Astronomical Union (IAU). The full atlas is available to the public through the Dawn Geographical Information System (GIS) web page [http://dawngis.dlr.de/atlas] and will become available through the NASA Planetary Data System (PDS) (http://pdssbn.astro.umd.edu/).

  7. Early birds are sexy: male age, dawn song and extrapair paternity in blue tits, Cyanistes (formerly Parus) caeruleus

    DEFF Research Database (Denmark)

    Poesel, Angelika; Kunc, H.P.; Foerster, K.

    2006-01-01

    Sexual selection theory predicts that signals reflecting the relative quality of individuals should be used in mate choice. Females could base their choice of copulation partners on male secondary sexual traits that honestly signal male age, as predicted by the age-based indicator mechanism....... Studies have shown that female blue tits prefer older males and that aspects of dawn song reflect male quality, but it remains unknown whether dawn song characteristics correlate with male age. We compared dawn song characteristics of second-year (SY) and older (ASY) male blue tits (cross......-sectional analysis), and tested for age-related changes within individuals (longitudinal analysis) and differential overwinter survival of SY males. We further investigated the relation between dawn song and paternity gain and loss. We found that ASY male blue tits began to sing earlier relative to sunrise than did...

  8. Evidence for ground-ice occurrence on asteroid Vesta using Dawn bistatic radar observations

    Science.gov (United States)

    Palmer, E. M.; Heggy, E.; Kofman, W. W.

    2017-12-01

    From 2011 to 2012, the Dawn spacecraft orbited asteroid Vesta, the first of its two targets in the asteroid belt, and conducted the first bistatic radar (BSR) experiment at a small-body, during which Dawn's high-gain communications antenna is used to transmit radar waves that scatter from Vesta's surface toward Earth at high incidence angles just before and after occultation of the spacecraft behind the asteroid. Among the 14 observed mid-latitude forward-scatter reflections, the radar cross section ranges from 84 ± 8 km2 (near Saturnalia Fossae) to 3,588 ± 200 km2 (northwest of Caparronia crater), implying substantial spatial variation in centimeter- to decimeter-scale surface roughness. The compared distributions of surface roughness and subsurface hydrogen concentration [H]—measured using data from Dawn's BSR experiment and Gamma Ray and Neutron Spectrometer (GRaND), respectively—reveal the occurrence of heightened subsurface [H] with smoother terrains that cover tens of square kilometers. Furthermore, unlike on the Moon, we observe no correlation between surface roughness and surface ages on Vesta—whether the latter is derived from lunar or asteroid-flux chronology [Williams et al., 2014]—suggesting that cratering processes alone are insufficient to explain Vesta's surface texture at centimeter-to-decimeter scales. Dawn's BSR observations support the hypothesis of transient melting, runoff and recrystallization of potential ground-ice deposits, which are postulated to flow along fractures after an impact, and provide a mechanism for the smoothing of otherwise rough, fragmented impact ejecta. Potential ground-ice presence within Vesta's subsurface was first proposed by Scully et al. [2014], who identified geomorphological evidence for transient water flow along several of Vesta's crater walls using Dawn Framing Camera images. While airless, differentiated bodies such as Vesta and the Moon are thought to have depleted their initial volatile content

  9. Preparing for Dawn's Mission at Ceres: Challenges and Opportunities in the Exploration of a Dwarf Planet

    Science.gov (United States)

    Rayman, Marc D.; Mase, Robert A.

    2014-01-01

    After escaping from Vesta in 2012, Dawn is continuing its 2.5-year flight to dwarf planet Ceres. Investigating this second destination promises to provide a view of an intriguing world of ice and rock, likely displaying fascinating geology entirely unlike any body yet orbited by a spacecraft. Dawn spends the significant majority of the time thrusting with its ion propulsion system to deliver the 3.6 km/s required to rendezvous with Ceres. Meanwhile, the operations team has developed the sequences that will be used there. Following orbit capture in March 2015, Dawn will fly to a series of four circular polar science orbits. The orbits, ranging from about 13,500 km to 375 km in altitude, are designed to optimize the scientific observations. The overall strategy for exploring Ceres is based strongly on the extremely successful 16 months of Vesta operations, during which Dawn met or exceeded all of its objectives. Nevertheless, the loss of two of the spacecraft's four reaction wheels has necessitated some important changes. Based on a very productive hydrazine conservation campaign in the interplanetary cruise and the development of new hydrazine-efficient methods of operating at Ceres, there is good reason to expect that Dawn will be able to accomplish all of its objectives regardless of the health of the reaction wheels. This paper describes the progress in traveling to Ceres as well as the plans for exploring this giant, icy world.

  10. Wide-field LOFAR-LBA power-spectra analyses: Impact of calibration, polarization leakage and ionosphere

    Science.gov (United States)

    Gehlot, Bharat K.; Koopmans, Léon V. E.

    2018-05-01

    Contamination due to foregrounds, calibration errors and ionospheric effects pose major challenges in detection of the cosmic 21 cm signal in various Epoch of Reionization (EoR) experiments. We present the results of a study of a field centered on 3C196 using LOFAR Low Band observations, where we quantify various wide field and calibration effects such as gain errors, polarized foregrounds, and ionospheric effects. We observe a `pitchfork' structure in the power spectrum of the polarized intensity in delay-baseline space, which leaks into the modes beyond the instrumental horizon. We show that this structure arises due to strong instrumental polarization leakage (~30%) towards Cas A which is far away from primary field of view. We measure a small ionospheric diffractive scale towards CasA resembling pure Kolmogorov turbulence. Our work provides insights in understanding the nature of aforementioned effects and mitigating them in future Cosmic Dawn observations.

  11. The Data Acquisition and Calibration System for the ATLAS Semiconductor Tracker

    CERN Document Server

    Abdesselam, A; Barr, A J; Bell, P; Bernabeu, J; Butterworth, J M; Carter, J R; Carter, A A; Charles, E; Clark, A; Colijn, A P; Costa, M J; Dalmau, J M; Demirkoz, B; Dervan, P J; Donega, M; D'Onifrio, M; Escobar, C; Fasching, D; Ferguson, D P S; Ferrari, P; Ferrère, D; Fuster, J; Gallop, B; García, C; González, S; González-Sevilla, S; Goodrick, M J; Gorisek, A; Greenall, A; Grillo, A A; Hessey, N P; Hill, J C; Jackson, J N; Jared, R C; Johannson, P D C; de Jong, P; Joseph, J; Lacasta, C; Lane, J B; Lester, C G; Limper, M; Lindsay, S W; McKay, R L; Magrath, C A; Mangin-Brinet, M; Martí i García, S; Mellado, B; Meyer, W T; Mikulec, B; Minano, M; Mitsou, V A; Moorhead, G; Morrissey, M; Paganis, E; Palmer, M J; Parker, M A; Pernegger, H; Phillips, A; Phillips, P W; Postranecky, M; Robichaud-Véronneau, A; Robinson, D; Roe, S; Sandaker, H; Sciacca, F; Sfyrla, A; Stanecka, E; Stapnes, S; Stradling, A; Tyndel, M; Tricoli, A; Vickey, T; Vossebeld, J H; Warren, M R M; Weidberg, A R; Wells, P S; Wu, S L

    2008-01-01

    The SemiConductor Tracker (SCT) data acquisition (DAQ) system will calibrate, configure, and control the approximately six million front-end channels of the ATLAS silicon strip detector. It will provide a synchronized bunch-crossing clock to the front-end modules, communicate first-level triggers to the front-end chips, and transfer information about hit strips to the ATLAS high-level trigger system. The system has been used extensively for calibration and quality assurance during SCT barrel and endcap assembly and for performance confirmation tests after transport of the barrels and endcaps to CERN. Operating in data-taking mode, the DAQ has recorded nearly twenty million synchronously-triggered events during commissioning tests including almost a million cosmic ray triggered events. In this paper we describe the components of the data acquisition system, discuss its operation in calibration and data-taking modes and present some detector performance results from these tests.

  12. The data acquisition and calibration system for the ATLAS Semiconductor Tracker

    International Nuclear Information System (INIS)

    Abdesselam, A; Barr, A J; Demirkoez, B; Barber, T; Carter, J R; Bell, P; Bernabeu, J; Costa, M J; Escobar, C; Butterworth, J M; Carter, A A; Dalmau, J M; Charles, E; Fasching, D; Ferguson, D P S; Clark, A; Donega, M; D'Onifrio, M; Colijn, A-P; Dervan, P J

    2008-01-01

    The SemiConductor Tracker (SCT) data acquisition (DAQ) system will calibrate, configure, and control the approximately six million front-end channels of the ATLAS silicon strip detector. It will provide a synchronized bunch-crossing clock to the front-end modules, communicate first-level triggers to the front-end chips, and transfer information about hit strips to the ATLAS high-level trigger system. The system has been used extensively for calibration and quality assurance during SCT barrel and endcap assembly and for performance confirmation tests after transport of the barrels and endcaps to CERN. Operating in data-taking mode, the DAQ has recorded nearly twenty million synchronously-triggered events during commissioning tests including almost a million cosmic ray triggered events. In this paper we describe the components of the data acquisition system, discuss its operation in calibration and data-taking modes and present some detector performance results from these tests

  13. Health information technology knowledge and skills needed by HIT employers.

    Science.gov (United States)

    Fenton, S H; Gongora-Ferraez, M J; Joost, E

    2012-01-01

    To evaluate the health information technology (HIT) workforce knowledge and skills needed by HIT employers. Statewide face-to-face and online focus groups of identified HIT employer groups in Austin, Brownsville, College Station, Dallas, El Paso, Houston, Lubbock, San Antonio, and webinars for rural health and nursing informatics. HIT employers reported needing an HIT workforce with diverse knowledge and skills ranging from basic to advanced, while covering information technology, privacy and security, clinical practice, needs assessment, contract negotiation, and many other areas. Consistent themes were that employees needed to be able to learn on the job and must possess the ability to think critically and problem solve. Many employers wanted persons with technical skills, yet also the knowledge and understanding of healthcare operations. The HIT employer focus groups provided valuable insight into employee skills needed in this fast-growing field. Additionally, this information will be utilized to develop a statewide HIT workforce needs assessment survey.

  14. The ATLAS Inner Detector commissioning and calibration

    CERN Document Server

    Aad, G.; Abdallah, J.; Abdelalim, A.A.; Abdesselam, A.; Abdinov, O.; Abi, B.; Abolins, M.; Abramowicz, H.; Abreu, H.; Acharya, B.S.; Adams, D.L.; Addy, T.N.; Adelman, J.; Adorisio, C.; Adragna, P.; Adye, T.; Aefsky, S.; Aguilar-Saavedra, J.A.; Aharrouche, M.; Ahlen, S.P.; Ahles, F.; Ahmad, A.; Ahsan, M.; Aielli, G.; Akdogan, T.; Akesson, T.P.A.; Akimoto, G.; Akimov, A.V.; Aktas, A.; Alam, M.S.; Alam, M.A.; Albert, J.; Albrand, S.; Aleksa, M.; Aleksandrov, I.N.; Alexa, C.; Alexander, G.; Alexandre, G.; Alexopoulos, T.; Alhroob, M.; Aliev, M.; Alimonti, G.; Alison, J.; Aliyev, M.; Allport, P.P.; Allwood-Spiers, S.E.; Almond, J.; Aloisio, A.; Alon, R.; Alonso, A.; Alviggi, M.G.; Amako, K.; Amelung, C.; Amorim, A.; Amoros, G.; Amram, N.; Anastopoulos, C.; Andeen, T.; Anders, C.F.; Anderson, K.J.; Andreazza, A.; Andrei, V.; Anduaga, X.S.; Angerami, A.; Anghinolfi, F.; Anjos, N.; Annovi, A.; Antonaki, A.; Antonelli, M.; Antonelli, S.; Antos, J.; Antunovic, B.; Anulli, F.; Aoun, S.; Arabidze, G.; Aracena, I.; Arai, Y.; Arce, A.T.H.; Archambault, J.P.; Arfaoui, S.; Arguin, J-F.; Argyropoulos, T.; Arik, M.; Armbruster, A.J.; Arnaez, O.; Arnault, C.; Artamonov, A.; Arutinov, D.; Asai, M.; Asai, S.; Asfandiyarov, R.; Ask, S.; Asman, B.; Asner, D.; Asquith, L.; Assamagan, K.; Astbury, A.; Astvatsatourov, A.; Atoian, G.; Auerbach, B.; Augsten, K.; Aurousseau, M.; Austin, N.; Avolio, G.; Avramidou, R.; Axen, D.; Ay, C.; Azuelos, G.; Azuma, Y.; Baak, M.A.; Bach, A.M.; Bachacou, H.; Bachas, K.; Backes, M.; Badescu, E.; Bagnaia, P.; Bai, Y.; Bain, T.; Baines, J.T.; Baker, O.K.; Baker, M.D.; Baker, S.; Baltasar Dos, F.Santos Pedrosa; Banas, E.; Banerjee, P.; Banerjee, S.; Banfi, D.; Bangert, A.; Bansal, V.; Baranov, S.P.; Baranov, S.; Barashkou, A.; Barber, T.; Barberio, E.L.; Barberis, D.; Barbero, M.; Bardin, D.Y.; Barillari, T.; Barisonzi, M.; Barklow, T.; Barlow, N.; Barnett, B.M.; Barnett, R.M.; Baroncelli, A.; Barr, A.J.; Barreiro, F.; Guimara, J.Barreiro; Barrillon, P.; Bartoldus, R.; Bartsch, D.; Bates, R.L.; Batkova, L.; Batley, J.R.; Battaglia, A.; Battistin, M.; Bauer, F.; Bawa, H.S.; Bazalova, M.; Beare, B.; Beau, T.; Beauchemin, P.H.; Beccherle, R.; Bechtle, P.; Beck, G.A.; Beck, H.P.; Beckingham, M.; Becks, K.H.; Beddall, A.J.; Beddall, A.; Bednyakov, V.A.; Bee, C.; Begel, M.; Behar Harpaz, S.; Behera, P.K.; Beimforde, M.; Belanger-Champagne, C.; Bell, P.J.; Bell, W.H.; Bella, G.; Bellagamba, L.; Bellina, F.; Bellomo, M.; Belloni, A.; Belotskiy, K.; Beltramello, O.; Ben Ami, S.; Benary, O.; Benchekroun, D.; Bendel, M.; Benedict, B.H.; Benekos, N.; Benhammou, Y.; Benincasa, G.P.; Benjamin, D.P.; Benoit, M.; Bensinger, J.R.; Benslama, K.; Bentvelsen, S.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Berghaus, F.; Berglund, E.; Beringer, J.; Bernat, P.; Bernhard, R.; Bernius, C.; Berry, T.; Bertin, A.; Besana, M.I.; Besson, N.; Bethke, S.; Bianchi, R.M.; Bianco, M.; Biebel, O.; Biesiada, J.; Biglietti, M.; Bilokon, H.; Bindi, M.; Binet, S.; Bingul, A.; Bini, C.; Biscarat, C.; Bitenc, U.; Black, K.M.; Blair, R.E.; Blanchard, J-B.; Blanchot, G.; Blocker, C.; Blondel, A.; Blum, W.; Blumenschein, U.; Bobbink, G.J.; Bocci, A.; Boehler, M.; Boek, J.; Boelaert, N.; Boser, S.; Bogaerts, J.A.; Bohm, C.; Bohm, J.; Boisvert, V.; Bold, T.; Boldea, V.; Bondarenko, V.G.; Bondioli, M.; Boonekamp, M.; Bordoni, S.; Borer, C.; Borisov, A.; Borissov, G.; Borjanovic, I.; Borroni, S.; Bos, K.; Boscherini, D.; Bosman, M.; Boterenbrood, H.; Bouchami, J.; Boudreau, J.; Bouhova-Thacker, E.V.; Boulahouache, C.; Bourdarios, C.; Boveia, A.; Boyd, J.; Boyko, I.R.; Bozovic-Jelisavcic, I.; Bracinik, J.; Braem, A.; Branchini, P.; Brandenburg, G.W.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J.E.; Braun, H.M.; Brelier, B.; Bremer, J.; Brenner, R.; Bressler, S.; Britton, D.; Brochu, F.M.; Brock, I.; Brock, R.; Brodet, E.; Bromberg, C.; Brooijmans, G.; Brooks, W.K.; Brown, G.; Bruckman de Renstrom, P.A.; Bruncko, D.; Bruneliere, R.; Brunet, S.; Bruni, A.; Bruni, G.; Bruschi, M.; Bucci, F.; Buchanan, J.; Buchholz, P.; Buckley, A.G.; Budagov, I.A.; Budick, B.; Buscher, V.; Bugge, L.; Bulekov, O.; Bunse, M.; Buran, T.; Burckhart, H.; Burdin, S.; Burgess, T.; Burke, S.; Busato, E.; Bussey, P.; Buszello, C.P.; Butin, F.; Butler, B.; Butler, J.M.; Buttar, C.M.; Butterworth, J.M.; Byatt, T.; Caballero, J.; Urban, S.Cabrera; Caforio, D.; Cakir, O.; Calafiura, P.; Calderini, G.; Calfayan, P.; Calkins, R.; Caloba, L.P.; Calvet, D.; Camarri, P.; Cameron, D.; Campana, S.; Campanelli, M.; Canale, V.; Canelli, F.; Canepa, A.; Cantero, J.; Capasso, L.; Capeans Garrido, M.D.M.; Caprini, I.; Caprini, M.; Capua, M.; Caputo, R.; Caramarcu, C.; Cardarelli, R.; Carli, T.; Carlino, G.; Carminati, L.; Caron, B.; Caron, S.; Carrillo Montoya, G.D.; Carron Montero, S.; Carter, A.A.; Carter, J.R.; Carvalho, J.; Casadei, D.; Casado, M.P.; Cascella, M.; Castaneda Hernadez, A.M.; Castaneda-Miranda, E.; Castillo Gimenez, V.; Castro, N.F.; Cataldi, G.; Catinaccio, A.; Catmore, J.R.; Cattai, A.; Cattani, G.; Caughron, S.; Cauz, D.; Cavalleri, P.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Ceradini, F.; Cerqueira, A.S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cetin, S.A.; Chafaq, A.; Chakraborty, D.; Chan, K.; Chapman, J.D.; Chapman, J.W.; Chareyre, E.; Charlton, D.G.; Chavda, V.; Cheatham, S.; Chekanov, S.; Chekulaev, S.V.; Chelkov, G.A.; Chen, H.; Chen, S.; Chen, X.; Cheplakov, A.; Chepurnov, V.F.; Cherkaoui El, R.Moursli; Tcherniatine, V.; Chesneanu, D.; Cheu, E.; Cheung, S.L.; Chevalier, L.; Chevallier, F.; Chiarella, V.; Chiefari, G.; Chikovani, L.; Childers, J.T.; Chilingarov, A.; Chiodini, G.; Chizhov, V.; Choudalakis, G.; Chouridou, S.; Christidi, I.A.; Christov, A.; Chromek-Burckhart, D.; Chu, M.L.; Chudoba, J.; Ciapetti, G.; Ciftci, A.K.; Ciftci, R.; Cinca, D.; Cindro, V.; Ciobotaru, M.D.; Ciocca, C.; Ciocio, A.; Cirilli, M.; Citterio, M.; Clark, A.; Clark, P.J.; Cleland, W.; Clemens, J.C.; Clement, B.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Coggeshall, J.; Cogneras, E.; Colijn, A.P.; Collard, C.; Collins, N.J.; Collins-Tooth, C.; Collot, J.; Colon, G.; Muino, P.Conde; Coniavitis, E.; Conidi, M.C.; Consonni, M.; Constantinescu, S.; Conta, C.; Conventi, F.; Cooke, M.; Cooper, B.D.; Cooper-Sarkar, A.M.; Cooper-Smith, N.J.; Copic, K.; Cornelissen, T.; Corradi, M.; Corriveau, F.; Corso-Radu, A.; Cortes-Gonzalez, A.; Cortiana, G.; Costa, G.; Costa, M.J.; Costanzo, D.; Costin, T.; Cote, D.; Coura Torres, R.; Courneyea, L.; Cowan, G.; Cowden, C.; Cox, B.E.; Cranmer, K.; Cranshaw, J.; Cristinziani, M.; Crosetti, G.; Crupi, R.; Crepe-Renaudin, S.; Cuenca Almenar, C.; Cuhadar Donszelmann, T.; Curatolo, M.; Curtis, C.J.; Cwetanski, P.; Czyczula, Z.; D'Auria, S.; D'Onofrio, M.; D'Orazio, A.; Da Via, C.; Dabrowski, W.; Dai, T.; Dallapiccola, C.; Dam, M.; Danielsson, H.O.; Dannheim, D.; Dao, V.; Darbo, G.; Darlea, G.L.; Davey, W.; Davidek, T.; Davidson, N.; Davidson, R.; Davies, M.; Davison, A.R.; Dawson, I.; Daya, R.K.; De, K.; de Asmundis, R.; De Castro, S.; De Castro, P.E.Faria Salgado; De Cecco, S.; de Graat, J.; De Groot, N.; de Jong, P.; De Mora, L.; De Oliveira, M.Branco; De Pedis, D.; De Salvo, A.; De Sanctis, U.; De Santo, A.; De Vivie De Regie, J.B.; De Zorzi, G.; Dean, S.; Dedovich, D.V.; Degenhardt, J.; Dehchar, M.; Del Papa, C.; Del Peso, J.; Del Prete, T.; Dell'Acqua, A.; Dell'Asta, L.; Della Pietra, M.; della Volpe, D.; Delmastro, M.; Delsart, P.A.; Deluca, C.; Demers, S.; Demichev, M.; Demirkoz, B.; Deng, J.; Deng, W.; Denisov, S.P.; Derkaoui, J.E.; Derue, F.; Dervan, P.; Desch, K.; Deviveiros, P.O.; Dewhurst, A.; DeWilde, B.; Dhaliwal, S.; Dhullipudi, R.; Di Ciaccio, A.; Di Ciaccio, L.; Di Domenico, A.; Di Girolamo, A.; Di Girolamo, B.; Di Luise, S.; Di Mattia, A.; Di Nardo, R.; Di Simone, A.; Di Sipio, R.; Diaz, M.A.; Diblen, F.; Diehl, E.B.; Dietrich, J.; Dietzsch, T.A.; Diglio, S.; Dindar Yagci, K.; Dingfelder, D.J.; Dionisi, C.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djilkibaev, R.; Djobava, T.; Vale, M.A.B.do; Do Valle, A.Wemans; Doan, T.K.O.; Dobos, D.; Dobson, E.; Dobson, M.; Doglioni, C.; Doherty, T.; Dolejsi, J.; Dolenc, I.; Dolezal, Z.; Dolgoshein, B.A.; Dohmae, T.; Donega, M.; Donini, J.; Dopke, J.; Doria, A.; Dos Anjos, A.; Dotti, A.; Dova, M.T.; Doxiadis, A.; Doyle, A.T.; Drasal, Z.; Dris, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Dudarev, A.; Dudziak, F.; Duhrssen, M.; Duflot, L.; Dufour, M-A.; Dunford, M.; Duran Yildiz, H.; Dushkin, A.; Duxfield, R.; Dwuznik, M.; Duren, M.; Ebenstein, W.L.; Ebke, J.; Eckweiler, S.; Edmonds, K.; Edwards, C.A.; Egorov, K.; Ehrenfeld, W.; Ehrich, T.; Eifert, T.; Eigen, G.; Einsweiler, K.; Eisenhandler, E.; Ekelof, T.; El Kacimi, M.; Ellert, M.; Elles, S.; Ellinghaus, F.; Ellis, K.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Engelmann, R.; Engl, A.; Epp, B.; Eppig, A.; Erdmann, J.; Ereditato, A.; Eriksson, D.; Ermoline, I.; Ernst, J.; Ernst, M.; Ernwein, J.; Errede, D.; Errede, S.; Ertel, E.; Escalier, M.; Escobar, C.; Espinal Curull, X.; Esposito, B.; Etienvre, A.I.; Etzion, E.; Evans, H.; Fabbri, L.; Fabre, C.; Facius, K.; Fakhrutdinov, R.M.; Falciano, S.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farley, J.; Farooque, T.; Farrington, S.M.; Farthouat, P.; Fassnacht, P.; Fassouliotis, D.; Fatholahzadeh, B.; Fayard, L.; Fayette, F.; Febbraro, R.; Federic, P.; Fedin, O.L.; Fedorko, W.; Feligioni, L.; Felzmann, C.U.; Feng, C.; Feng, E.J.; Fenyuk, A.B.; Ferencei, J.; Ferland, J.; Fernandes, B.; Fernando, W.; Ferrag, S.; Ferrando, J.; Ferrara, V.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferrer, A.; Ferrer, M.L.; Ferrere, D.; Ferretti, C.; Fiascaris, M.; Fiedler, F.; Filipcic, A.; Filippas, A.; Filthaut, F.; Fincke-Keeler, M.; Fiolhais, M.C.N.; Fiorini, L.; Firan, A.; Fischer, G.; Fisher, M.J.; Flechl, M.; Fleck, I.; Fleckner, J.; Fleischmann, P.; Fleischmann, S.; Flick, T.; Flores Castillo, L.R.; Flowerdew, M.J.; Fonseca Martin, T.; Formica, A.; Forti, A.; Fortin, D.; Fournier, D.; Fowler, A.J.; Fowler, K.; Fox, H.; Francavilla, P.; Franchino, S.; Francis, D.; Franklin, M.; Franz, S.; Fraternali, M.; Fratina, S.; Freestone, J.; French, S.T.; Froeschl, R.; Froidevaux, D.; Frost, J.A.; Fukunaga, C.; Fullana Torregrosa, E.; Fuster, J.; Gabaldon, C.; Gabizon, O.; Gadfort, T.; Gadomski, S.; Gagliardi, G.; Gagnon, P.; Galea, C.; Gallas, E.J.; Gallo, V.; Gallop, B.J.; Gallus, P.; Galyaev, E.; Gan, K.K.; Gao, Y.S.; Gaponenko, A.; Garcia-Sciveres, M.; Garcia, C.; Navarro, J.E.Garcia; Gardner, R.W.; Garelli, N.; Garitaonandia, H.; Garonne, V.; Gatti, C.; Gaudio, G.; Gauzzi, P.; Gavrilenko, I.L.; Gay, C.; Gaycken, G.; Gazis, E.N.; Ge, P.; Gee, C.N.P.; Geich-Gimbel, Ch.; Gellerstedt, K.; Gemme, C.; Genest, M.H.; Gentile, S.; Georgatos, F.; George, S.; Gershon, A.; Ghazlane, H.; Ghodbane, N.; Giacobbe, B.; Giagu, S.; Giakoumopoulou, V.; Giangiobbe, V.; Gianotti, F.; Gibbard, B.; Gibson, A.; Gibson, S.M.; Gilbert, L.M.; Gilchriese, M.; Gilewsky, V.; Gingrich, D.M.; Ginzburg, J.; Giokaris, N.; Giordani, M.P.; Giordano, R.; Giorgi, F.M.; Giovannini, P.; Giraud, P.F.; Girtler, P.; Giugni, D.; Giusti, P.; Gjelsten, B.K.; Gladilin, L.K.; Glasman, C.; Glazov, A.; Glitza, K.W.; Glonti, G.L.; Godfrey, J.; Godlewski, J.; Goebel, M.; Gopfert, T.; Goeringer, C.; Gossling, C.; Gottfert, T.; Goggi, V.; Goldfarb, S.; Goldin, D.; Golling, T.; Gomes, A.; Gomez Fajardo, L.S.; Goncalo, R.; Gonella, L.; Gong, C.; Gonzalez de la Hoz, S.; Gonzalez Silva, M.L.; Gonzalez-Sevilla, S.; Goodson, J.J.; Goossens, L.; Gordon, H.A.; Gorelov, I.; Gorfine, G.; Gorini, B.; Gorini, E.; Gorisek, A.; Gornicki, E.; Gosdzik, B.; Gosselink, M.; Gostkin, M.I.; Gough Eschrich, I.; Gouighri, M.; Goujdami, D.; Goulette, M.P.; Goussiou, A.G.; Goy, C.; Grabowska-Bold, I.; Grafstrom, P.; Grahn, K-J.; Grancagnolo, S.; Grassi, V.; Gratchev, V.; Grau, N.; Gray, H.M.; Gray, J.A.; Graziani, E.; Green, B.; Greenshaw, T.; Greenwood, Z.D.; Gregor, I.M.; Grenier, P.; Griesmayer, E.; Griffiths, J.; Grigalashvili, N.; Grillo, A.A.; Grimm, K.; Grinstein, S.; Grishkevich, Y.V.; Groh, M.; Groll, M.; Gross, E.; Grosse-Knetter, J.; Groth-Jensen, J.; Grybel, K.; Guicheney, C.; Guida, A.; Guillemin, T.; Guler, H.; Gunther, J.; Guo, B.; Gusakov, Y.; Gutierrez, A.; Gutierrez, P.; Guttman, N.; Gutzwiller, O.; Guyot, C.; Gwenlan, C.; Gwilliam, C.B.; Haas, A.; Haas, S.; Haber, C.; Hadavand, H.K.; Hadley, D.R.; Haefner, P.; Hartel, R.; Hajduk, Z.; Hakobyan, H.; Haller, J.; Hamacher, K.; Hamilton, A.; Hamilton, S.; Han, L.; Hanagaki, K.; Hance, M.; Handel, C.; Hanke, P.; Hansen, J.R.; Hansen, J.B.; Hansen, J.D.; Hansen, P.H.; Hansl-Kozanecka, T.; Hansson, P.; Hara, K.; Hare, G.A.; Harenberg, T.; Harrington, R.D.; Harris, O.M.; Harrison, K.; Hartert, J.; Hartjes, F.; Harvey, A.; Hasegawa, S.; Hasegawa, Y.; Hashemi, K.; Hassani, S.; Haug, S.; Hauschild, M.; Hauser, R.; Havranek, M.; Hawkes, C.M.; Hawkings, R.J.; Hayakawa, T.; Hayward, H.S.; Haywood, S.J.; Head, S.J.; Hedberg, V.; Heelan, L.; Heim, S.; Heinemann, B.; Heisterkamp, S.; Helary, L.; Heller, M.; Hellman, S.; Helsens, C.; Hemperek, T.; Henderson, R.C.W.; Henke, M.; Henrichs, A.; Henriques Correia, A.M.; Henrot-Versille, S.; Hensel, C.; Henss, T.; Hernandez Jimenez, Y.; Hershenhorn, A.D.; Herten, G.; Hertenberger, R.; Hervas, L.; Hessey, N.P.; Higon-Rodriguez, E.; Hill, J.C.; Hiller, K.H.; Hillert, S.; Hillier, S.J.; Hinchliffe, I.; Hines, E.; Hirose, M.; Hirsch, F.; Hirschbuehl, D.; Hobbs, J.; Hod, N.; Hodgkinson, M.C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M.R.; Hoffman, J.; Hoffmann, D.; Hohlfeld, M.; Holy, T.; Holzbauer, J.L.; Homma, Y.; Horazdovsky, T.; Hori, T.; Horn, C.; Horner, S.; Horvat, S.; Hostachy, J-Y.; Hou, S.; Hoummada, A.; Howe, T.; Hrivnac, J.; Hryn'ova, T.; Hsu, P.J.; Hsu, S.C.; Huang, G.S.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T.B.; Hughes, E.W.; Hughes, G.; Hurwitz, M.; Husemann, U.; Huseynov, N.; Huston, J.; Huth, J.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idarraga, J.; Iengo, P.; Igonkina, O.; Ikegami, Y.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ince, T.; Ioannou, P.; Iodice, M.; Irles Quiles, A.; Ishikawa, A.; Ishino, M.; Ishmukhametov, R.; Isobe, T.; Issever, C.; Istin, S.; Itoh, Y.; Ivashin, A.V.; Iwasaki, H.; Izen, J.M.; Izzo, V.; Jackson, B.; Jackson, J.N.; Jackson, P.; Jaekel, M.R.; Jain, V.; Jakobs, K.; Jakobsen, S.; Jakubek, J.; Jana, D.; Jankowski, E.; Jansen, E.; Jantsch, A.; Janus, M.; Jared, R.C.; Jarlskog, G.; Jeanty, L.; Plante, I.Jen-La; Jenni, P.; Jez, P.; Jezequel, S.; Ji, W.; Jia, J.; Jiang, Y.; Jimenez Belenguer, M.; Jin, S.; Jinnouchi, O.; Joffe, D.; Johansen, M.; Johansson, K.E.; Johansson, P.; Johnert, S.; Johns, K.A.; Jon-And, K.; Jones, G.; Jones, R.W.L.; Jones, T.J.; Jorge, P.M.; Joseph, J.; Juranek, V.; Jussel, P.; Kabachenko, V.V.; Kaci, M.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kaiser, S.; Kajomovitz, E.; Kalinin, S.; Kalinovskaya, L.V.; Kama, S.; Kanaya, N.; Kaneda, M.; Kantserov, V.A.; Kanzaki, J.; Kaplan, B.; Kapliy, A.; Kaplon, J.; Kar, D.; Karagounis, M.; Karagoz Unel, M.; Karnevskiy, M.; Kartvelishvili, V.; Karyukhin, A.N.; Kashif, L.; Kasmi, A.; Kass, R.D.; Kastanas, A.; Kastoryano, M.; Kataoka, M.; Kataoka, Y.; Katsoufis, E.; Katzy, J.; Kaushik, V.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kayl, M.S.; Kayumov, F.; Kazanin, V.A.; Kazarinov, M.Y.; Keates, J.R.; Keeler, R.; Keener, P.T.; Kehoe, R.; Keil, M.; Kekelidze, G.D.; Kelly, M.; Kenyon, M.; Kepka, O.; Kerschen, N.; Kersevan, B.P.; Kersten, S.; Kessoku, K.; Khakzad, M.; Khalil-zada, F.; Khandanyan, H.; Khanov, A.; Kharchenko, D.; Khodinov, A.; Khomich, A.; Khoriauli, G.; Khovanskiy, N.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kim, H.; Kim, M.S.; Kim, P.C.; Kim, S.H.; Kind, O.; Kind, P.; King, B.T.; Kirk, J.; Kirsch, G.P.; Kirsch, L.E.; Kiryunin, A.E.; Kisielewska, D.; Kittelmann, T.; Kiyamura, H.; Kladiva, E.; Klein, M.; Klein, U.; Kleinknecht, K.; Klemetti, M.; Klier, A.; Klimentov, A.; Klingenberg, R.; Klinkby, E.B.; Klioutchnikova, T.; Klok, P.F.; Klous, S.; Kluge, E.E.; Kluge, T.; Kluit, P.; Klute, M.; Kluth, S.; Knecht, N.S.; Kneringer, E.; Ko, B.R.; Kobayashi, T.; Kobel, M.; Koblitz, B.; Kocian, M.; Kocnar, A.; Kodys, P.; Koneke, K.; Konig, A.C.; Koenig, S.; Kopke, L.; Koetsveld, F.; Koevesarki, P.; Koffas, T.; Koffeman, E.; Kohn, F.; Kohout, Z.; Kohriki, T.; Kolanoski, H.; Kolesnikov, V.; Koletsou, I.; Koll, J.; Kollar, D.; Kolos, S.; Kolya, S.D.; Komar, A.A.; Komaragiri, J.R.; Kondo, T.; Kono, T.; Konoplich, R.; Konovalov, S.P.; Konstantinidis, N.; Koperny, S.; Korcyl, K.; Kordas, K.; Korn, A.; Korolkov, I.; Korolkova, E.V.; Korotkov, V.A.; Kortner, O.; Kostka, P.; Kostyukhin, V.V.; Kotov, S.; Kotov, V.M.; Kotov, K.Y.; Kourkoumelis, C.; Koutsman, A.; Kowalewski, R.; Kowalski, H.; Kowalski, T.Z.; Kozanecki, W.; Kozhin, A.S.; Kral, V.; Kramarenko, V.A.; Kramberger, G.; Krasny, M.W.; Krasznahorkay, A.; Kraus, J.; Kreisel, A.; Krejci, F.; Kretzschmar, J.; Krieger, N.; Krieger, P.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Kruger, H.; Krumshteyn, Z.V.; Kubota, T.; Kuehn, S.; Kugel, A.; Kuhl, T.; Kuhn, D.; Kukhtin, V.; Kulchitsky, Y.; Kuleshov, S.; Kummer, C.; Kuna, M.; Kunkle, J.; Kupco, A.; Kurashige, H.; Kurata, M.; Kurchaninov, L.L.; Kurochkin, Y.A.; Kus, V.; Kwee, R.; La Rosa, A.; La Rotonda, L.; Labbe, J.; Lacasta, C.; Lacava, F.; Lacker, H.; Lacour, D.; Lacuesta, V.R.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Lamanna, M.; Lampen, C.L.; Lampl, W.; Lancon, E.; Landgraf, U.; Landon, M.P.J.; Lane, J.L.; Lankford, A.J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Laplace, S.; Lapoire, C.; Laporte, J.F.; Lari, T.; Larner, A.; Lassnig, M.; Laurelli, P.; Lavrijsen, W.; Laycock, P.; Lazarev, A.B.; Lazzaro, A.; Le Dortz, O.; Le Guirriec, E.; Le Menedeu, E.; Le Vine, M.; Lebedev, A.; Lebel, C.; LeCompte, T.; Ledroit-Guillon, F.; Lee, H.; Lee, J.S.H.; Lee, S.C.; Lefebvre, M.; Legendre, M.; LeGeyt, B.C.; Legger, F.; Leggett, C.; Lehmacher, M.; Lehmann Miotto, G.; Lei, X.; Leitner, R.; Lellouch, D.; Lellouch, J.; Lendermann, V.; Leney, K.J.C.; Lenz, T.; Lenzen, G.; Lenzi, B.; Leonhardt, K.; Leroy, C.; Lessard, J-R.; Lester, C.G.; Leung Fook, A.Cheong; Leveque, J.; Levin, D.; Levinson, L.J.; Leyton, M.; Li, H.; Li, X.; Liang, Z.; Liang, Z.; Liberti, B.; Lichard, P.; Lichtnecker, M.; Lie, K.; Liebig, W.; Lilley, J.N.; Limosani, A.; Limper, M.; Lin, S.C.; Linnemann, J.T.; Lipeles, E.; Lipinsky, L.; Lipniacka, A.; Liss, T.M.; Lissauer, D.; Lister, A.; Litke, A.M.; Liu, C.; Liu, D.; Liu, H.; Liu, J.B.; Liu, M.; Liu, T.; Liu, Y.; Livan, M.; Lleres, A.; Lloyd, S.L.; Lobodzinska, E.; Loch, P.; Lockman, W.S.; Lockwitz, S.; Loddenkoetter, T.; Loebinger, F.K.; Loginov, A.; Loh, C.W.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, R.E.; Lopes, L.; Lopez Mateos, D.; Losada, M.; Loscutoff, P.; Lou, X.; Lounis, A.; Loureiro, K.F.; Lovas, L.; Love, J.; Love, P.A.; Lowe, A.J.; Lu, F.; Lubatti, H.J.; Luci, C.; Lucotte, A.; Ludwig, A.; Ludwig, D.; Ludwig, I.; Luehring, F.; Luisa, L.; Lumb, D.; Luminari, L.; Lund, E.; Lund-Jensen, B.; Lundberg, B.; Lundberg, J.; Lundquist, J.; Lynn, D.; Lys, J.; Lytken, E.; Ma, H.; Ma, L.L.; Macana Goia, J.A.; Maccarrone, G.; Macchiolo, A.; Macek, B.; Machado Miguens, J.; Mackeprang, R.; Madaras, R.J.; Mader, W.F.; Maenner, R.; Maeno, T.; Mattig, P.; Mattig, S.; Magalhaes Martins, P.J.; Magradze, E.; Mahalalel, Y.; Mahboubi, K.; Mahmood, A.; Maiani, C.; Maidantchik, C.; Maio, A.; Majewski, S.; Makida, Y.; Makouski, M.; Makovec, N.; Malecki, Pa.; Malecki, P.; Maleev, V.P.; Malek, F.; Mallik, U.; Malon, D.; Maltezos, S.; Malyshev, V.; Malyukov, S.; Mambelli, M.; Mameghani, R.; Mamuzic, J.; Mandelli, L.; Mandic, I.; Mandrysch, R.; Maneira, J.; Mangeard, P.S.; Manjavidze, I.D.; Manning, P.M.; Manousakis-Katsikakis, A.; Mansoulie, B.; Mapelli, A.; Mapelli, L.; March, L.; Marchand, J.F.; Marchese, F.; Marchiori, G.; Marcisovsky, M.; Marino, C.P.; Marroquim, F.; Marshall, Z.; Marti-Garcia, S.; Martin, A.J.; Martin, A.J.; Martin, B.; Martin, B.; Martin, F.F.; Martin, J.P.; Martin, T.A.; Dit Latour, B.Martin; Martinez, M.; Martinez Outschoorn, V.; Martini, A.; Martyniuk, A.C.; Marzano, F.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A.L.; Massa, I.; Massol, N.; Mastroberardino, A.; Masubuchi, T.; Matsunaga, H.; Matsushita, T.; Mattravers, C.; Maxfield, S.J.; Mayne, A.; Mazini, R.; Mazur, M.; Mazzanti, M.; Mc Donald, J.; Mc Kee, S.P.; McCarn, A.; McCarthy, R.L.; McCubbin, N.A.; McFarlane, K.W.; McGlone, H.; Mchedlidze, G.; McMahon, S.J.; McPherson, R.A.; Meade, A.; Mechnich, J.; Mechtel, M.; Medinnis, M.; Meera-Lebbai, R.; Meguro, T.M.; Mehlhase, S.; Mehta, A.; Meier, K.; Meirose, B.; Melachrinos, C.; Mellado Garcia, B.R.; Mendoza Navas, L.; Meng, Z.; Menke, S.; Meoni, E.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F.S.; Messina, A.M.; Metcalfe, J.; Mete, A.S.; Meyer, J-P.; Meyer, J.; Meyer, J.; Meyer, T.C.; Meyer, W.T.; Miao, J.; Michal, S.; Micu, L.; Middleton, R.P.; Migas, S.; Mijovic, L.; Mikenberg, G.; Mikestikova, M.; Mikuz, M.; Miller, D.W.; Mills, W.J.; Mills, C.M.; Milov, A.; Milstead, D.A.; Milstein, D.; Minaenko, A.A.; Minano, M.; Minashvili, I.A.; Mincer, A.I.; Mindur, B.; Mineev, M.; Ming, Y.; Mir, L.M.; Mirabelli, G.; Misawa, S.; Miscetti, S.; Misiejuk, A.; Mitrevski, J.; Mitsou, V.A.; Miyagawa, P.S.; Mjornmark, J.U.; Mladenov, D.; Moa, T.; Moed, S.; Moeller, V.; Monig, K.; Moser, N.; Mohr, W.; Mohrdieck-Mock, S.; Moles-Valls, R.; Molina-Perez, J.; Monk, J.; Monnier, E.; Montesano, S.; Monticelli, F.; Moore, R.W.; Mora Herrera, C.; Moraes, A.; Morais, A.; Morel, J.; Morello, G.; Moreno, D.; Llacer, M.Moreno; Morettini, P.; Morii, M.; Morley, A.K.; Mornacchi, G.; Morozov, S.V.; Morris, J.D.; Moser, H.G.; Mosidze, M.; Moss, J.; Mount, R.; Mountricha, E.; Mouraviev, S.V.; Moyse, E.J.W.; Mudrinic, M.; Mueller, F.; Mueller, J.; Mueller, K.; Muller, T.A.; Muenstermann, D.; Muir, A.; Munwes, Y.; Murillo Garcia, R.; Murray, W.J.; Mussche, I.; Musto, E.; Myagkov, A.G.; Myska, M.; Nadal, J.; Nagai, K.; Nagano, K.; Nagasaka, Y.; Nairz, A.M.; Nakamura, K.; Nakano, I.; Nakatsuka, H.; Nanava, G.; Napier, A.; Nash, M.; Nation, N.R.; Nattermann, T.; Naumann, T.; Navarro, G.; Nderitu, S.K.; Neal, H.A.; Nebot, E.; Nechaeva, P.; Negri, A.; Negri, G.; Nelson, A.; Nelson, T.K.; Nemecek, S.; Nemethy, P.; Nepomuceno, A.A.; Nessi, M.; Neubauer, M.S.; Neusiedl, A.; Neves, R.N.; Nevski, P.; Newcomer, F.M.; Nickerson, R.B.; Nicolaidou, R.; Nicolas, L.; Nicoletti, G.; Nicquevert, B.; Niedercorn, F.; Nielsen, J.; Nikiforov, A.; Nikolaev, K.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsen, H.; Nilsson, P.; Nisati, A.; Nishiyama, T.; Nisius, R.; Nodulman, L.; Nomachi, M.; Nomidis, I.; Nordberg, M.; Nordkvist, B.; Notz, D.; Novakova, J.; Nozaki, M.; Nozicka, M.; Nugent, I.M.; Nuncio-Quiroz, A.E.; Nunes Hanninger, G.; Nunnemann, T.; Nurse, E.; O'Neil, D.C.; O'Shea, V.; Oakham, F.G.; Oberlack, H.; Ochi, A.; Oda, S.; Odaka, S.; Odier, J.; Ogren, H.; Oh, A.; Oh, S.H.; Ohm, C.C.; Ohshima, T.; Ohshita, H.; Ohsugi, T.; Okada, S.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olchevski, A.G.; Oliveira, M.; Oliveira Damazio, D.; Oliver, J.; Oliver Garcia, E.; Olivito, D.; Olszewski, A.; Olszowska, J.; Omachi, C.; Onofre, A.; Onyisi, P.U.E.; Oram, C.J.; Oreglia, M.J.; Oren, Y.; Orestano, D.; Orlov, I.; Oropeza Barrera, C.; Orr, R.S.; Ortega, E.O.; Osculati, B.; Ospanov, R.; Osuna, C.; Ottersbach, J.P.; Ould-Saada, F.; Ouraou, A.; Ouyang, Q.; Owen, M.; Owen, S.; Oyarzun, A.; Ozcan, V.E.; Ozone, K.; Ozturk, N.; Pacheco Pages, A.; Padilla Aranda, C.; Paganis, E.; Pahl, C.; Paige, F.; Pajchel, K.; Palestini, S.; Pallin, D.; Palma, A.; Palmer, J.D.; Pan, Y.B.; Panagiotopoulou, E.; Panes, B.; Panikashvili, N.; Panitkin, S.; Pantea, D.; Panuskova, M.; Paolone, V.; Papadopoulou, Th.D.; Park, S.J.; Park, W.; Parker, M.A.; Parker, S.I.; Parodi, F.; Parsons, J.A.; Parzefall, U.; Pasqualucci, E.; Passeri, A.; Pastore, F.; Pastore, Fr.; Pasztor, G.; Pataraia, S.; Pater, J.R.; Patricelli, S.; Patwa, A.; Pauly, T.; Peak, L.S.; Pecsy, M.; Pedraza Morales, M.I.; Peleganchuk, S.V.; Peng, H.; Penson, A.; Penwell, J.; Perantoni, M.; Perez, K.; Perez Codina, E.; Perez Garcia-Estan, M.T.; Perez Reale, V.; Perini, L.; Pernegger, H.; Perrino, R.; Persembe, S.; Perus, P.; Peshekhonov, V.D.; Petersen, B.A.; Petersen, T.C.; Petit, E.; Petridou, C.; Petrolo, E.; Petrucci, F.; Petschull, D.; Petteni, M.; Pezoa, R.; Phan, A.; Phillips, A.W.; Piacquadio, G.; Piccinini, M.; Piegaia, R.; Pilcher, J.E.; Pilkington, A.D.; Pina, J.; Pinamonti, M.; Pinfold, J.L.; Pinto, B.; Pizio, C.; Placakyte, R.; Plamondon, M.; Pleier, M.A.; Poblaguev, A.; Poddar, S.; Podlyski, F.; Poffenberger, P.; Poggioli, L.; Pohl, M.; Polci, F.; Polesello, G.; Policicchio, A.; Polini, A.; Poll, J.; Polychronakos, V.; Pomeroy, D.; Pommes, K.; Pontecorvo, L.; Pope, B.G.; Popovic, D.S.; Poppleton, A.; Popule, J.; Portell Bueso, X.; Porter, R.; Pospelov, G.E.; Pospisil, S.; Potekhin, M.; Potrap, I.N.; Potter, C.J.; Potter, C.T.; Potter, K.P.; Poulard, G.; Poveda, J.; Prabhu, R.; Pralavorio, P.; Prasad, S.; Pravahan, R.; Pribyl, L.; Price, D.; Price, L.E.; Prichard, P.M.; Prieur, D.; Primavera, M.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Prudent, X.; Przysiezniak, H.; Psoroulas, S.; Ptacek, E.; Puigdengoles, C.; Purdham, J.; Purohit, M.; Puzo, P.; Pylypchenko, Y.; Qi, M.; Qian, J.; Qian, W.; Qin, Z.; Quadt, A.; Quarrie, D.R.; Quayle, W.B.; Quinonez, F.; Raas, M.; Radeka, V.; Radescu, V.; Radics, B.; Rador, T.; Ragusa, F.; Rahal, G.; Rahimi, A.M.; Rajagopalan, S.; Rammensee, M.; Rammes, M.; Rauscher, F.; Rauter, E.; Raymond, M.; Read, A.L.; Rebuzzi, D.M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reeves, K.; Reinherz-Aronis, E.; Reinsch, A.; Reisinger, I.; Reljic, D.; Rembser, C.; Ren, Z.L.; Renkel, P.; Rescia, S.; Rescigno, M.; Resconi, S.; Resende, B.; Reznicek, P.; Rezvani, R.; Richards, A.; Richards, R.A.; Richter, R.; Richter-Was, E.; Ridel, M.; Rijpstra, M.; Rijssenbeek, M.; Rimoldi, A.; Rinaldi, L.; Rios, R.R.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Roa Romero, D.A.; Robertson, S.H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J.E.M.; Robinson, M.; Robson, A.; Rocha de Lima, J.G.; Roda, C.; Roda Dos, D.Santos; Rodriguez, D.; Rodriguez Garcia, Y.; Roe, S.; Rohne, O.; Rojo, V.; Rolli, S.; Romaniouk, A.; Romanov, V.M.; Romeo, G.; Romero Maltrana, D.; Roos, L.; Ros, E.; Rosati, S.; Rosenbaum, G.A.; Rosselet, L.; Rossetti, V.; Rossi, L.P.; Rotaru, M.; Rothberg, J.; Rousseau, D.; Royon, C.R.; Rozanov, A.; Rozen, Y.; Ruan, X.; Ruckert, B.; Ruckstuhl, N.; Rud, V.I.; Rudolph, G.; Ruhr, F.; Ruggieri, F.; Ruiz-Martinez, A.; Rumyantsev, L.; Rurikova, Z.; Rusakovich, N.A.; Rutherfoord, J.P.; Ruwiedel, C.; Ruzicka, P.; Ryabov, Y.F.; Ryan, P.; Rybkin, G.; Rzaeva, S.; Saavedra, A.F.; Sadrozinski, H.F-W.; Sadykov, R.; Safai Tehrani, F.; Sakamoto, H.; Salamanna, G.; Salamon, A.; Saleem, M.S.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvachua Ferrando, B.M.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sampsonidis, D.; Samset, B.H.; Sanchis Lozano, M.A.; Sandaker, H.; Sander, H.G.; Sanders, M.P.; Sandhoff, M.; Sandhu, P.; Sandstroem, R.; Sandvoss, S.; Sankey, D.P.C.; Sanny, B.; Sansoni, A.; Santamarina Rios, C.; Santoni, C.; Santonico, R.; Saraiva, J.G.; Sarangi, T.; Sarkisyan-Grinbaum, E.; Sarri, F.; Sasaki, O.; Sasao, N.; Satsounkevitch, I.; Sauvage, G.; Savard, P.; Savine, A.Y.; Savinov, V.; Sawyer, L.; Saxon, D.H.; Says, L.P.; Sbarra, C.; Sbrizzi, A.; Scannicchio, D.A.; Schaarschmidt, J.; Schacht, P.; Schafer, U.; Schaetzel, S.; Schaffer, A.C.; Schaile, D.; Schamberger, R.D.; Schamov, A.G.; Scharf, V.; Schegelsky, V.A.; Scheirich, D.; Schernau, M.; Scherzer, M.I.; Schiavi, C.; Schieck, J.; Schioppa, M.; Schlenker, S.; Schmidt, E.S.; Schmieden, K.; Schmitt, C.; Schmitz, M.; Schonig, A.; Schott, M.; Schouten, D.; Schovancova, J.; Schram, M.; Schreiner, A.; Schroeder, C.; Schroer, N.; Schroers, M.; Schultes, J.; Schultz-Coulon, H.C.; Schumacher, J.W.; Schumacher, M.; Schumm, B.A.; Schune, Ph.; Schwanenberger, C.; Schwartzman, A.; Schwemling, Ph.; Schwienhorst, R.; Schwierz, R.; Schwindling, J.; Scott, W.G.; Searcy, J.; Sedykh, E.; Segura, E.; Seidel, S.C.; Seiden, A.; Seifert, F.; Seixas, J.M.; Sekhniaidze, G.; Seliverstov, D.M.; Sellden, B.; Semprini-Cesari, N.; Serfon, C.; Serin, L.; Seuster, R.; Severini, H.; Sevior, M.E.; Sfyrla, A.; Shabalina, E.; Shamim, M.; Shan, L.Y.; Shank, J.T.; Shao, Q.T.; Shapiro, M.; Shatalov, P.B.; Shaw, K.; Sherman, D.; Sherwood, P.; Shibata, A.; Shimojima, M.; Shin, T.; Shmeleva, A.; Shochet, M.J.; Shupe, M.A.; Sicho, P.; Sidoti, A.; Siegert, F.; Siegrist, J.; Sijacki, Dj.; Silbert, O.; Silva, J.; Silver, Y.; Silverstein, D.; Silverstein, S.B.; Simak, V.; Simic, Lj.; Simion, S.; Simmons, B.; Simonyan, M.; Sinervo, P.; Sinev, N.B.; Sipica, V.; Siragusa, G.; Sisakyan, A.N.; Sivoklokov, S.Yu.; Sjoelin, J.; Sjursen, T.B.; Skovpen, K.; Skubic, P.; Slater, M.; Slavicek, T.; Sliwa, K.; Sloper, J.; Sluka, T.; Smakhtin, V.; Smirnov, S.Yu.; Smirnov, Y.; Smirnova, L.N.; Smirnova, O.; Smith, B.C.; Smith, D.; Smith, K.M.; Smizanska, M.; Smolek, K.; Snesarev, A.A.; Snow, S.W.; Snow, J.; Snuverink, J.; Snyder, S.; Soares, M.; Sobie, R.; Sodomka, J.; Soffer, A.; Solans, C.A.; Solar, M.; Solc, J.; Solfaroli Camillocci, E.; Solodkov, A.A.; Solovyanov, O.V.; Soluk, R.; Sondericker, J.; Sopko, V.; Sopko, B.; Sosebee, M.; Soukharev, A.; Spagnolo, S.; Spano, F.; Spencer, E.; Spighi, R.; Spigo, G.; Spila, F.; Spiwoks, R.; Spousta, M.; Spreitzer, T.; Spurlock, B.; Denis, R.D.St.; Stahl, T.; Stahlman, J.; Stamen, R.; Stancu, S.N.; Stanecka, E.; Stanek, R.W.; Stanescu, C.; Stapnes, S.; Starchenko, E.A.; Stark, J.; Staroba, P.; Starovoitov, P.; Stastny, J.; Stavina, P.; Steele, G.; Steinbach, P.; Steinberg, P.; Stekl, I.; Stelzer, B.; Stelzer, H.J.; Stelzer-Chilton, O.; Stenzel, H.; Stevenson, K.; Stewart, G.; Stockton, M.C.; Stoerig, K.; Stoicea, G.; Stonjek, S.; Strachota, P.; Stradling, A.R.; Straessner, A.; Strandberg, J.; Strandberg, S.; Strandlie, A.; Strauss, M.; Strizenec, P.; Strohmer, R.; Strom, D.M.; Stroynowski, R.; Strube, J.; Stugu, B.; Sturm, P.; Soh, D.A.; Su, D.; Sugaya, Y.; Sugimoto, T.; Suhr, C.; Suk, M.; Sulin, V.V.; Sultansoy, S.; Sumida, T.; Sun, X.H.; Sundermann, J.E.; Suruliz, K.; Sushkov, S.; Susinno, G.; Sutton, M.R.; Suzuki, T.; Suzuki, Y.; Sykora, I.; Sykora, T.; Szymocha, T.; Sanchez, J.; Ta, D.; Tackmann, K.; Taffard, A.; Tafirout, R.; Taga, A.; Takahashi, Y.; Takai, H.; Takashima, R.; Takeda, H.; Takeshita, T.; Talby, M.; Talyshev, A.; Tamsett, M.C.; Tanaka, J.; Tanaka, R.; Tanaka, S.; Tanaka, S.; Tapprogge, S.; Tardif, D.; Tarem, S.; Tarrade, F.; Tartarelli, G.F.; Tas, P.; Tasevsky, M.; Tassi, E.; Tatarkhanov, M.; Taylor, C.; Taylor, F.E.; Taylor, G.N.; Taylor, R.P.; Taylor, W.; Teixeira-Dias, P.; Ten Kate, H.; Teng, P.K.; Tennenbaum-Katan, Y.D.; Terada, S.; Terashi, K.; Terron, J.; Terwort, M.; Testa, M.; Teuscher, R.J.; Therhaag, J.; Thioye, M.; Thoma, S.; Thomas, J.P.; Thompson, E.N.; Thompson, P.D.; Thompson, P.D.; Thompson, R.J.; Thompson, A.S.; Thomson, E.; Thun, R.P.; Tic, T.; Tikhomirov, V.O.; Tikhonov, Y.A.; Tipton, P.; Tique Aires, F.J.Viegas; Tisserant, S.; Toczek, B.; Todorov, T.; Todorova-Nova, S.; Toggerson, B.; Tojo, J.; Tokar, S.; Tokushuku, K.; Tollefson, K.; Tomasek, L.; Tomasek, M.; Tomoto, M.; Tompkins, L.; Toms, K.; Tonoyan, A.; Topfel, C.; Topilin, N.D.; Torchiani, I.; Torrence, E.; Pastor, E.Torro; Toth, J.; Touchard, F.; Tovey, D.R.; Trefzger, T.; Tremblet, L.; Tricoli, A.; Trigger, I.M.; Trincaz-Duvoid, S.; Trinh, T.N.; Tripiana, M.F.; Triplett, N.; Trischuk, W.; Trivedi, A.; Trocme, B.; Troncon, C.; Trzupek, A.; Tsarouchas, C.; Tseng, J.C-L.; Tsiakiris, M.; Tsiareshka, P.V.; Tsionou, D.; Tsipolitis, G.; Tsiskaridze, V.; Tskhadadze, E.G.; Tsukerman, I.I.; Tsulaia, V.; Tsung, J.W.; Tsuno, S.; Tsybychev, D.; Tuggle, J.M.; Turecek, D.; Turk Cakir, I.; Turlay, E.; Tuts, P.M.; Twomey, M.S.; Tylmad, M.; Tyndel, M.; Uchida, K.; Ueda, I.; Ueno, R.; Ugland, M.; Uhlenbrock, M.; Uhrmacher, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Unno, Y.; Urbaniec, D.; Urkovsky, E.; Urquijo, P.; Urrejola, P.; Usai, G.; Uslenghi, M.; Vacavant, L.; Vacek, V.; Vachon, B.; Vahsen, S.; Valente, P.; Valentinetti, S.; Valkar, S.; Valladolid Gallego, E.; Vallecorsa, S.; Valls Ferrer, J.A.; Van Berg, R.; van der Graaf, H.; van der Kraaij, E.; van der Poel, E.; van der Ster, D.; van Eldik, N.; van Gemmeren, P.; van Kesteren, Z.; van Vulpen, I.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vannucci, F.; Vari, R.; Varnes, E.W.; Varouchas, D.; Vartapetian, A.; Varvell, K.E.; Vasilyeva, L.; Vassilakopoulos, V.I.; Vazeille, F.; Vellidis, C.; Veloso, F.; Veneziano, S.; Ventura, A.; Ventura, D.; Venturi, M.; Venturi, N.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, J.C.; Vetterli, M.C.; Vichou, I.; Vickey, T.; Viehhauser, G.H.A.; Villa, M.; Villani, E.G.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M.G.; Vinek, E.; Vinogradov, V.B.; Viret, S.; Virzi, J.; Vitale, A.; Vitells, O.; Vivarelli, I.; Vives Vaque, F.; Vlachos, S.; Vlasak, M.; Vlasov, N.; Vogel, A.; Vokac, P.; Volpi, M.; von der Schmitt, H.; von Loeben, J.; von Radziewski, H.; von Toerne, E.; Vorobel, V.; Vorwerk, V.; Vos, M.; Voss, R.; Voss, T.T.; Vossebeld, J.H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vu Anh, T.; Vudragovic, D.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Walbersloh, J.; Walder, J.; Walker, R.; Walkowiak, W.; Wall, R.; Wang, C.; Wang, H.; Wang, J.; Wang, S.M.; Warburton, A.; Ward, C.P.; Warsinsky, M.; Wastie, R.; Watkins, P.M.; Watson, A.T.; Watson, M.F.; Watts, G.; Watts, S.; Waugh, A.T.; Waugh, B.M.; Weber, M.D.; Weber, M.; Weber, M.S.; Weber, P.; Weidberg, A.R.; Weingarten, J.; Weiser, C.; Wellenstein, H.; Wells, P.S.; Wen, M.; Wenaus, T.; Wendler, S.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M.; Werner, P.; Werth, M.; Werthenbach, U.; Wessels, M.; Whalen, K.; White, A.; White, M.J.; White, S.; Whitehead, S.R.; Whiteson, D.; Whittington, D.; Wicek, F.; Wicke, D.; Wickens, F.J.; Wiedenmann, W.; Wielers, M.; Wienemann, P.; Wiglesworth, C.; Wiik, L.A.M.; Wildauer, A.; Wildt, M.A.; Wilkens, H.G.; Williams, E.; Williams, H.H.; Willocq, S.; Wilson, J.A.; Wilson, M.G.; Wilson, A.; Wingerter-Seez, I.; Winklmeier, F.; Wittgen, M.; Wolter, M.W.; Wolters, H.; Wosiek, B.K.; Wotschack, J.; Woudstra, M.J.; Wraight, K.; Wright, C.; Wright, D.; Wrona, B.; Wu, S.L.; Wu, X.; Wulf, E.; Wynne, B.M.; Xaplanteris, L.; Xella, S.; Xie, S.; Xu, D.; Xu, N.; Yamada, M.; Yamamoto, A.; Yamamoto, K.; Yamamoto, S.; Yamamura, T.; Yamaoka, J.; Yamazaki, T.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, U.K.; Yang, Z.; Yao, W-M.; Yao, Y.; Yasu, Y.; Ye, J.; Ye, S.; Yilmaz, M.; Yoosoofmiya, R.; Yorita, K.; Yoshida, R.; Young, C.; Youssef, S.P.; Yu, D.; Yu, J.; Yuan, L.; Yurkewicz, A.; Zaidan, R.; Zaitsev, A.M.; Zajacova, Z.; Zambrano, V.; Zanello, L.; Zaytsev, A.; Zeitnitz, C.; Zeller, M.; Zemla, A.; Zendler, C.; Zenin, O.; Zenis, T.; Zenonos, Z.; Zenz, S.; Zerwas, D.; della Porta, G.Zevi; Zhan, Z.; Zhang, H.; Zhang, J.; Zhang, Q.; Zhang, X.; Zhao, L.; Zhao, T.; Zhao, Z.; Zhemchugov, A.; Zhong, J.; Zhou, B.; Zhou, N.; Zhou, Y.; Zhu, C.G.; Zhu, H.; Zhu, Y.; Zhuang, X.; Zhuravlov, V.; Zimmermann, R.; Zimmermann, S.; Zimmermann, S.; Ziolkowski, M.; Zivkovic, L.; Zobernig, G.; Zoccoli, A.; zur Nedden, M.

    2010-01-01

    The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data- taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1+/-0.9 {\\mu}m and a relative momentum resolution {\\sigma}p/p = (4.83+/-0.16)...

  15. A Two-Hit Model of Autism: Adolescence as the Second Hit

    Science.gov (United States)

    Picci, Giorgia; Scherf, K. Suzanne

    2015-01-01

    Adolescence brings dramatic changes in behavior and neural organization. Unfortunately, for some 30% of individuals with autism, there is marked decline in adaptive functioning during adolescence. We propose a two-hit model of autism. First, early perturbations in neural development function as a “first hit” that sets up a neural system that is “built to fail” in the face of a second hit. Second, the confluence of pubertal hormones, neural reorganization, and increasing social demands during adolescence provides the “second hit” that interferes with the ability to transition into adult social roles and levels of adaptive functioning. In support of this model, we review evidence about adolescent-specific neural and behavioral development in autism. We conclude with predictions and recommendations for empirical investigation about several domains in which developmental trajectories for individuals with autism may be uniquely deterred in adolescence. PMID:26609500

  16. 75 FR 21629 - HIT Standards Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2010-04-26

    ... Technology; HIT Standards Committee's Workgroup Meetings; Notice of Meetings AGENCY: Office of the National... only. Name of Committees: HIT Standards Committee's Workgroups: Clinical Operations Vocabulary... developed by the HIT Policy Committee. Date and Time: The HIT Standards Committee Workgroups will hold the...

  17. 77 FR 66617 - HIT Policy and Standards Committees; Workgroup Application Database

    Science.gov (United States)

    2012-11-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy and Standards Committees; Workgroup Application... of New ONC HIT FACA Workgroup Application Database. The Office of the National Coordinator (ONC) has.... Name of Committees: HIT Standards Committee and HIT Policy Committee. General Function of the...

  18. First detection of global dawn-dusk ionospheric current intensities using Ampere's integral law on Orsted orbits

    DEFF Research Database (Denmark)

    Stauning, P.; Primdahl, Fritz

    2000-01-01

    -to-dusk ionospheric current is found to be proportional to the gee-effective solar wind electric field and is around 1 million ampere for a typical solar wind electric field of 2 mV/m. Dividing the Ampere integral into semi-orbit parts has enabled us to show that the hemispherical total current intensities depend......The magnetic measurements by the Orsted satellite in noon-midnight orbits have enabled the derivation of the global dawn-dusk oriented ionospheric currents from an Ampere's law closed loop line integral of the geomagnetic vector field along the satellite track. The globally integrated dawn...... on the respective polar cap conductivities, which relate to the daily and seasonally varying solar illumination. The more illuminated hemisphere conveys up to three times more current from dawn to dusk than does the less illuminated....

  19. 76 FR 46297 - HIT Standards Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-08-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Standards Committee's... developed by the HIT Policy Committee. Date and Time: The HIT Standards Committee Workgroups will hold the...

  20. Parallel computing of a climate model on the dawn 1000 by domain decomposition method

    Science.gov (United States)

    Bi, Xunqiang

    1997-12-01

    In this paper the parallel computing of a grid-point nine-level atmospheric general circulation model on the Dawn 1000 is introduced. The model was developed by the Institute of Atmospheric Physics (IAP), Chinese Academy of Sciences (CAS). The Dawn 1000 is a MIMD massive parallel computer made by National Research Center for Intelligent Computer (NCIC), CAS. A two-dimensional domain decomposition method is adopted to perform the parallel computing. The potential ways to increase the speed-up ratio and exploit more resources of future massively parallel supercomputation are also discussed.

  1. Hit-and-run, hit-and-stay, and commensal bacteria present different peptide content when viewed from the perspective of the T cell.

    Science.gov (United States)

    He, Lu; De Groot, Anne S; Bailey-Kellogg, Chris

    2015-11-27

    Different types of bacteria face different pressures from the immune system, with those that persist ("hit-and-stay") potentially having to adapt more in order to escape than those prone to short-lived infection ("hit-and-run"), and with commensal bacteria potentially different from both due to additional physical mechanisms for avoiding immune detection. The Janus Immunogenicity Score (JIS) was recently developed to assess the likelihood of T cell recognition of an antigen, using an analysis that considers both binding of a peptide within the antigen by major histocompatability complex (MHC) and recognition of the peptide:MHC complex by cognate T cell receptor (TCR). This score was shown to be predictive of T effector vs. T regulatory or null responses in experimental data, as well as to distinguish viruses representative of the hit-and-stay vs. hit-and-run phenotypes. Here, JIS-based analyses were conducted in order to characterize the extent to which the pressure to avoid T cell recognition is manifested in genomic differences among representative hit-and-run, hit-and-stay, and commensal bacteria. Overall, extracellular proteins were found to have different JIS profiles from cytoplasmic ones. Contrasting the bacterial groups, extracellular proteins were shown to be quite different across the groups, much more so than intracellular proteins. The differences were evident even at the level of corresponding peptides in homologous protein pairs from hit-and-run and hit-and-stay bacteria. The multi-level analysis of patterns of immunogenicity across different groups of bacteria provides a new way to approach questions of bacterial immune camouflage or escape, as well as to approach the selection and optimization of candidates for vaccine design. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Is There an Association Between Heparin-Induced Thrombocytopenia (HIT) and Autoimmune Disease?

    Science.gov (United States)

    Klinkhammer, Brent; Gruchalla, Michael

    2018-03-01

    Heparin-induced thrombocytopenia (HIT) is a drug-induced, immunoglobulin G medicated autoimmune disorder associated with several negative clinical outcomes including increased morbidity, mortality, and increased medical costs. Previous studies have shown associations between comorbid autoimmune diseases, but there is little known about associations between HIT and autoimmunity. To provide clinical data to suggest an association between HIT and autoimmunity. Retrospective chart review of 59 cases with a diagnosis of HIT and 251 matched controls without a HIT diagnosis, comparing the prevalence of autoimmunity in each group. A single, large upper Midwest health care system. Patients with a diagnosis of HIT were significantly more likely to have a comorbid autoimmune disease than those without a HIT diagnosis (55.9% vs 10.8%, P HIT were significantly more likely to have a diagnosis of antiphospholipid syndrome (15.3% vs 0.0%, P HIT were significantly older than controls ( P HIT and autoimmune disease and suggests a need for more research into the relationship between HIT and autoimmunity. These results could alter the anticoagulation management of venous thromboembolism and acute coronary syndrome in patients with a previously identified autoimmune disease. Copyright© Wisconsin Medical Society.

  3. Updates in the IR responsivity of VIR, the spectrometer of the Dawn mission.

    Science.gov (United States)

    Ammannito, Eleonora; Mc Cord, Thomas B.; De Sanctis, Maria Cristina.; Combe, Jean-Philippe

    VIR-MS (Visual and Infrared Mapping Spectrometer) is the imaging spectrometer of the Dawn mission (1,2). Here, first we describe the computation of a new instrument responsivity based on the internal calibration data acquired during the operations at Vesta, and then we describe its effect on the dataset and on the results published so far. VIR-MS was built in Italy by a scientific-industrial (IAPS/INAF in Rome (Italy) and Selex ES in Campi Bisenzio (Fi, Italy)) consortium financially supported by the Italian Space Agency. VIR-MS is an high spatial resolution spectrometer (FOV of 64mrad, IFOV of 250 µrad) in the 0.25-5 µm range with an IFOV of 250 µrad and a spectral sampling of about 2 nm in the visible range and 10 nm in the IR range. The results of the on-ground calibration held in the Selex calibration facility in September 2005 were already presented and discussed in a paper (2). This version has been used to calibrate the data available on the Planetary Data System (PDS) Small Bodies Node, dataset used in all the papers published so far. However, after the operations at the asteroid Vesta, we have identified some artifacts in the instrument responsivity in the 2.5-3.5 µm region, which is where several absorption bands of OH and H2O occur. Those artifacts were systematic, and therefore they did not prevent the detection of relative spectral variations associated to OH and H2O. Actually, the only paper published in which are discussed spectra in this range (3) used a different calibration method described in the paper itself. This method used a simple correction of the response function based on an empirical calibration correction that is appropriate to recover the signal in that specific range. However, the absolute absorption band depth of OH and H2O could not be calculated. To compute a new instrument responsivity we used the internal lamp of the spectrometer. This lamp, made of a tungsten filament, is characterized by a blackbody-like emission at about

  4. ORIGIN: metal creation and evolution from the cosmic dawn

    NARCIS (Netherlands)

    den Herder, J.W.; Piro, L.; Ohashi, T.; Kouveliotou, C.; Hartmann, D.H.; Kaastra, J.S.; Amati, L.; Andersen, M.I.; Arnaud, M.; Atteia, J.-L.; Bandler, S.; Barbera, M.; Barcons, X.; Barthelmy, S.; Basa, S.; Basso, S.; de Boer, M.; Branchini, E.; Branduardi-Raymont, G.; Borgani, S.; Boyarsky, A.; Brunetti, G.; Budtz-Jorgensen, C.; Burrows, D.; Butler, N.; Campana, S.; Caroli, E.; Ceballos, M.; Christensen, F.; Churazov, E.; Comastri, A.; Colasanti, L.; Cole, R.; Content, R.; Corsi, A.; Costantini, E.; Conconi, P.; Cusumano, G.; de Plaa, J.; De Rosa, A.; Del Santo, M.; Di Cosimo, S.; De Pasquale, M.; Doriese, R.; Ettori, S.; Evans, P.; Ezoe, Y.; Ferrari, L.; Finger, H.; Figueroa-Feliciano, T.; Friedrich, P.; Fujimoto, R.; Furuzawa, A.; Fynbo, J.; Gatti, F.; Galeazzi, M.; Gehrels, N.; Gendre, B.; Ghirlanda, G.; Ghisellini, G.; Gilfanov, M.; Giommi, P.; Girardi, M.; Grindlay, J.; Cocchi, M.; Godet, O.; Guedel, M.; Haardt, F.; Hartog, R.; Hepburn, I.; Hermsen, W.; Hjorth, J.; Hoekstra, H.; Holland, A.; Hornstrup, A.; van der Horst, A.; Hoshino, A.; in 't Zand, J.; Irwin, K.; Ishisaki, Y.; Jonker, P.; Kitayama, T.; Kawahara, H.; Kawai, N.; Kelley, R.; Kilbourne, C.; de Korte, P.; Kusenko, A.; Kuvvetli, I.; Labanti, M.; Macculi, C.; Maiolino, R.; Mas Hesse, M.; Matsushita, K.; Mazzotta, P.; McCammon, D.; Méndez, M.; Mignani, R.; Mineo, T.; Mitsuda, K.; Mushotzky, R.; Molendi, S.; Moscardini, L.; Natalucci, L.; Nicastro, F.; O'Brien, P.; Osborne, J.; Paerels, F.; Page, M.; Paltani, S.; Pedersen, K.; Perinati, E.; Ponman, T.; Pointecouteau, E.; Predehl, P.; Porter, S.; Rasmussen, A.; Rauw, G.; Röttgering, H.; Roncarelli, M.; Rosati, P.; Quadrini, E.; Ruchayskiy, O.; Salvaterra, R.; Sasaki, S.; Sato, K.; Savaglio, S.; Schaye, J.; Sciortino, S.; Shaposhnikov, M.; Sharples, R.; Shinozaki, K.; Spiga, D.; Sunyaev, R.; Suto, Y.; Takei, Y.; Tanvir, N.; Tashiro, M.; Tamura, T.; Tawara, Y.; Troja, E.; Tsujimoto, M.; Tsuru, T.; Ubertini, P.; Ullom, J.; Ursino, E.; Verbunt, F.; van de Voort, F.; Viel, M.; Wachter, S.; Watson, D.; Weisskopf, M.; Werner, N.; White, N.; Willingale, R.; Wijers, R.; Yamasaki, N.; Yoshikawa, K.; Zane, S.

    2012-01-01

    ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z = 10,

  5. ORIGIN : Metal creation and evolution from the cosmic dawn

    NARCIS (Netherlands)

    den Herder, Jan-Willem; Piro, Luigi; Ohashi, Takaya; Kouveliotou, Chryssa; Hartmann, Dieter H.; Kaastra, Jelle S.; Amati, L.; Andersen, M. I.; Arnaud, M.; Attéia, J.-L.; Bandler, S.; Barbera, M.; Barcons, X.; Barthelmy, S.; Basa, S.; Basso, S.; Boer, M.; Branchini, E.; Branduardi-Raymont, G.; Borgani, S.; Boyarsky, A.; Brunetti, G.; Budtz-Jorgensen, C.; Burrows, D.; Butler, N.; Campana, S.; Caroli, E.; Ceballos, M.; Christensen, F.; Churazov, E.; Comastri, A.; Colasanti, L.; Cole, R.; Content, R.; Corsi, A.; Costantini, E.; Conconi, P.; Cusumano, G.; de Plaa, J.; De Rosa, A.; Del Santo, M.; Di Cosimo, S.; De Pasquale, M.; Doriese, R.; Ettori, S.; Evans, P.; Ezoe, Y.; Ferrari, L.; Finger, H.; Figueroa-Feliciano, T.; Friedrich, P.; Fujimoto, R.; Furuzawa, A.; Fynbo, J.; Gatti, F.; Galeazzi, M.; Gehrels, N.; Gendre, B.; Ghirlanda, G.; Ghisellini, G.; Gilfanov, M.; Giommi, P.; Girardi, M.; Grindlay, J.; Cocchi, M.; Godet, O.; Guedel, M.; Haardt, F.; den Hartog, R.; Hepburn, I.; Hermsen, W.; Hjorth, J.; Hoekstra, H.; Holland, A.; Hornstrup, A.; van der Horst, A.; Hoshino, A.; in't Zand, J.; Irwin, K.; Ishisaki, Y.; Jonker, P.; Kitayama, T.; Kawahara, H.; Kawai, N.; Kelley, R.; Kilbourne, C.; de Korte, P.; Kusenko, A.; Kuvvetli, I.; Labanti, M.; Macculi, C.; Maiolino, R.; Hesse, M. Mas; Matsushita, K.; Mazzotta, P.; McCammon, D.; Méndez, M.; Mignani, R.; Mineo, T.; Mitsuda, K.; Mushotzky, R.; Molendi, S.; Moscardini, L.; Natalucci, L.; Nicastro, F.; O'Brien, P.; Osborne, J.; Paerels, F.; Page, M.; Paltani, S.; Pedersen, K.; Perinati, E.; Ponman, T.; Pointecouteau, E.; Predehl, P.; Porter, S.; Rasmussen, A.; Rauw, G.; Röttgering, H.; Roncarelli, M.; Rosati, P.; Quadrini, E.; Ruchayskiy, O.; Salvaterra, R.; Sasaki, S.; Sato, K.; Savaglio, S.; Schaye, J.; Sciortino, S.; Shaposhnikov, M.; Sharples, R.; Shinozaki, K.; Spiga, D.; Sunyaev, R.; Suto, Y.; Takei, Y.; Tanvir, N.; Tashiro, M.; Tamura, T.; Tawara, Y.; Troja, E.; Tsujimoto, M.; Tsuru, T.; Ubertini, P.; Ullom, J.; Ursino, E.; Verbunt, F.; van de Voort, F.; Viel, M.; Wachter, S.; Watson, D.; Weisskopf, M.; Werner, N.; White, N.; Willingale, R.; Wijers, R.; Yamasaki, N.; Yoshikawa, K.; Zane, S.

    2012-01-01

    ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z = 10,

  6. Do pigeons prefer alternatives that include near-hit outcomes?

    Science.gov (United States)

    Stagner, Jessica P; Case, Jacob P; Sticklen, Mary F; Duncan, Amanda K; Zentall, Thomas R

    2015-07-01

    Pigeons show suboptimal choice on a gambling-like task similar to that shown by humans. Humans also show a preference for gambles in which there are near hits (losses that come close to winning). In the present research, we asked if pigeons would show a preference for alternatives with near-hit-like trials. In Experiment 1, we included an alternative that presented a near hit, in which a stimulus associated with reinforcement (a presumed conditioned reinforcer) changed to a stimulus associated with the absence of reinforcement (a presumed conditioned inhibitor). The pigeons tended to avoid this alternative. In Experiment 2, we varied the duration of the presumed conditioned reinforcer (2 vs. 8 s) that changed to a presumed conditioned inhibitor (8 vs. 2 s) and found that the longer the conditioned reinforcer was presented, the more the pigeons avoided it. In Experiment 3, the near-hit alternative involved an ambiguous stimulus for 8 s that changed to a presumed conditioned reinforcer (or a presumed conditioned inhibitor) for 2 s, but the pigeons still avoided it. In Experiment 4, we controlled for the duration of the conditioned reinforcer by presenting it first for 2 s followed by the ambiguous stimulus for 8 s. Once again, the pigeons avoided the alternative with the near-hit trials. In all 4 experiments, the pigeons tended to avoid alternatives that provided near-hit-like trials. We concluded that humans may be attracted to near-hit trials because near-hit trials give them the illusion of control, whereas this does not appear to be a factor for pigeons. (c) 2015 APA, all rights reserved).

  7. Combined hit theory-microdosimetric explanation of cellular radiobiological action

    International Nuclear Information System (INIS)

    Bond, V.P.; Varma, M.N.

    1983-01-01

    Hit theory is combined with microdosimetry in a stochastic approach that explains the observed responses of cell populations exposed in radiation fields of different qualities. The central thesis is that to expose a population of cells in a low-level radiation field is to subject the cells to the potential for interaction with charged particles in the vicinity of the cells, quantifiable in terms of the charged particle fluence theta. When such an interaction occurs there is a resulting stochastic transfer of energy to a critical volume (CV) of cross section sigma, within the cell(s). The severity of cell injury is dependent on the amount of energy thus imparted, or the hit size. If the severity is above some minimal level, there is a non-zero probability that the injury will result in a quantal effect (e.g., a mutational or carcinogenic initial event, cell transformation). A microdosimetric proportional counter, viewed here as a phantom cell CV that permits measurements not possible in the living cell, is used to determine the incidence of hit cells and the spectrum of hit sizes. Each hit is then weighted on the basis of an empirically-determined function that provides the fraction of cells responding quantally, as a function of hit size. The sum of the hits so weighted provides the incidence of quantally-responding cells, for any amount of exposure theta in a radiation field of any quality or mixture qualities. The hit size weighting function for pink mutations in Tradescantia is discussed, as are its implications in terms of a replacement for RBE and dose equivalent. 14 references, 9 figures

  8. Lead generation and examples opinion regarding how to follow up hits.

    Science.gov (United States)

    Orita, Masaya; Ohno, Kazuki; Warizaya, Masaichi; Amano, Yasushi; Niimi, Tatsuya

    2011-01-01

    In fragment-based drug discovery (FBDD), not only identifying the starting fragment hit to be developed but also generating a drug lead from that starting fragment hit is important. Converting fragment hits to leads is generally similar to a high-throughput screening (HTS) hits-to-leads approach in that properties associated with activity for a target protein, such as selectivity against other targets and absorption, distribution, metabolism, excretion, and toxicity (ADME/Tox), and physicochemical properties should be taken into account. However, enhancing the potency of the fragment hit is a key requirement in FBDD, unlike HTS, because initial fragment hits are generally weak. This enhancement is presently achieved by adding additional chemical groups which bind to additional parts of the target protein or by joining or combining two or more hit fragments; however, strategies for effecting greater improvements in effective activity are needed. X-ray analysis is a key technology attractive for converting fragments to drug leads. This method makes it clear whether a fragment hit can act as an anchor and provides insight regarding introduction of functional groups to improve fragment activity. Data on follow-up chemical synthesis of fragment hits has allowed for the differentiation of four different strategies: fragment optimization, fragment linking, fragment self-assembly, and fragment evolution. Here, we discuss our opinion regarding how to follow up on fragment hits, with a focus on the importance of fragment hits as an anchor moiety to so-called hot spots in the target protein using crystallographic data. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Rare transformation to double hit lymphoma in Waldenstrom's macroglobulinemia.

    Science.gov (United States)

    Okolo, Onyemaechi N; Johnson, Ariel C; Yun, Seongseok; Arnold, Stacy J; Anwer, Faiz

    2017-08-01

    Waldenström macroglobulinemia (WM) is a lymphoproliferative lymphoma that is characterized by monoclonal immunoglobulin M (IgM) protein and bone marrow infiltration. Its incidence is rare and rarer still is its ability to transform to a B-cell lymphoma, particularly the aggressive diffuse large B-cell lymphoma, which bodes a poor prognosis. When transformation includes mutations of MYC, BCL-2 and/or BCL-6, it is known as a 'double hit' or 'triple hit' lymphoma respectively. This paper presents a rare case of WM with mutations positive for MYC and BCL2, making it a case of double hit B-cell lymphoplasmacytic lymphoma with plasmatic differentiation without morphological transformation to aggressive histology like DLBCL. The paper also broadens to include discussions on current topics in the classification, diagnosis, possible causes of transformation, and treatment of WM, including transformation to double hit lymphoma. The significance of this case lies in that the presence of double hit lymphoma-like genetic mutations in WM have not been previously described in the literature and potentially such changes are harbinger of extra-nodal presentation, aggressive growth, and possibly poor prognosis, if data from other double-hit lymphoma are extrapolated.

  10. Chemical Mixing Model and K-Th-Ti Systematics and HED Meteorites for the Dawn Mission

    Science.gov (United States)

    Usui, T.; McSween, H. Y., Jr.; Mittlefehldt, D. W.; Prettyman, T. H.

    2009-01-01

    The Dawn mission will explore 4 Vesta, a large differentiated asteroid believed to be the parent body of the howardite, eucrite and diogenite (HED) meteorite suite. The Dawn spacecraft carries a gamma-ray and neutron detector (GRaND), which will measure the abundances of selected elements on the surface of Vesta. This study provides ways to leverage the large geochemical database on HED meteorites as a tool for interpreting chemical analyses by GRaND of mapped units on the surface of Vesta.

  11. Overview of the HIT-SI3 spheromak experiment

    Science.gov (United States)

    Hossack, A. C.; Jarboe, T. R.; Chandra, R. N.; Morgan, K. D.; Sutherland, D. A.; Everson, C. J.; Penna, J. M.; Nelson, B. A.

    2017-10-01

    The HIT-SI and HIT-SI3 spheromak experiments (a = 23 cm) study efficient, steady-state current drive for magnetic confinement plasmas using a novel method which is ideal for low aspect ratio, toroidal geometries. Sustained spheromaks show coherent, imposed plasma motion and low plasma-generated mode activity, indicating stability. Analysis of surface magnetic fields in HIT-SI indicates large n = 0 and 1 mode amplitudes and little energy in higher modes. Within measurement uncertainties all the n = 1 energy is imposed by the injectors, rather than being plasma-generated. The fluctuating field imposed by the injectors is sufficient to sustain the toroidal current through dynamo action whereas the plasma-generated field is not (Hossack et al., Phys. Plasmas, 2017). Ion Doppler spectroscopy shows coherent, imposed plasma motion inside r 10 cm in HIT-SI and a smaller volume of coherent motion in HIT-SI3. Coherent motion indicates the spheromak is stable and a lack of plasma-generated n = 1 energy indicates the maximum q is maintained below 1 for stability during sustainment. In HIT-SI3, the imposed mode structure is varied to test the plasma response (Hossack et al., Nucl. Fusion, 2017). Imposing n = 2, n = 3, or large, rotating n = 1 perturbations is correlated with transient plasma-generated activity. Work supported by the U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences, under Award Number DE-FG02-96ER54361.

  12. Summary of KOMPSAT-5 Calibration and Validation

    Science.gov (United States)

    Yang, D.; Jeong, H.; Lee, S.; Kim, B.

    2013-12-01

    Korean Multi-Purpose Satellite 5 (KOMPSAT-5), equipped with high resolution X-band (9.66 GHz) Synthetic Aperture Radar (SAR), is planning to be launched on August 22, 2013. With the satellite's primary mission objective being providing Geographical Information System (GIS), Ocean monitoring and Land management, and Disaster and ENvironment monitoring (GOLDEN), it is expected that its applications for scientific research on geographical processes will be extensive. In order to meet its mission objective, the KOMPSAT-5 will provide three different kinds of SAR imaging modes; High Resolution Mode (1 m resolution, 5 km swath), Standard Mode (3 m resolution, 30 km swath), and Wide Swath Mode (20 m resolution, 100 km swath). The KOMPSAT-5 will be operated in a 550 km sun-synchronous, dawn- dusk orbit with a 28-day ground repeat cycle providing valuable image information on Earth surface day-or-night and even in bad weather condition. After successful launch of the satellite, it will go through Launch and Early Operation (LEOP) and In-Orbit Testing (IOT) period about for 6 months to carry out various tests on satellite bus and payload systems. The satellite bus system will be tested during the first 3 weeks after the launch focusing on the Attitude and Orbit Control Subsystem (AOCS) and Integrated GPS Occultation Receiver (IGOR) calibration. With the completion of bus system test, the SAR payload system will be calibrated during initial In-Flight check period (11 weeks) by the joint effort of Thales Alenia Space Italy (TAS-I) and Korea Aerospace Research Institute (KARI). The pointing and relative calibration will be carried out during this period by analyzing the doppler frequency and antenna beam pattern of reflected microwave signal from selected regions with uniform backscattering coefficients (e.g. Amazon rainforest). A dedicated SAR calibration, called primary calibration, will be allocated at the end of LEOP for 12 weeks to perform thorough calibration activities

  13. Exploring Vesta's Surface Roughness and Dielectric Properties Using VIR Spectrometer and Bistatic Radar Observations by the Dawn Mission

    Science.gov (United States)

    Palmer, E. M.; Heggy, E.; Capria, M. T.; Tosi, F.; Kofman, W. W.; Russell, C. T.

    2014-12-01

    Multiple lines of evidence from NASA's Dawn mission suggest transient volatile presence at the surface of asteroid Vesta. Radar remote sensing is a useful technique for the investigation of volatile content at the surface and shallow subsurface, but requires the use of accurate dielectric and topographic models in order to deconvolve the effect of surface roughness from the total observed radar backscatter. Toward this end, we construct a dielectric model for the dry, volatile-poor case of Vesta's surface to represent average surface conditions, and to assess the expected average range of dielectric properties due to known variations in mineralogy, temperature, and density as inferred from Dawn VIR data. We employ dielectric studies of lunar samples to serve as a suitable analog to the Vestan regolith, and in the case of 10-wavelength penetration depth of X-band frequency radar observations, our model yields ɛ' from 2.5 to 2.6 from the night to dayside of Vesta, and tan δ from 0.011 to 0.014. Our estimation of ɛ' corresponds to specular surface reflectivity of ~0.05. In addition to modeling, we have also conducted an opportunistic bistatic radar (BSR) experiment at Vesta using the communications antennas aboard Dawn and on Earth. In this configuration, Dawn transmits a continuous radar signal toward the Earth while orbiting Vesta. As the Dawn spacecraft passes behind Vesta (entering an occultation), the line of sight between Dawn and Earth intersects Vesta's surface, resulting in a reflection of radar waves from the surface and shallow subsurface, which are then received on Earth for analysis. The geometry of the Dawn BSR experiment results in high incidence angles on Vesta's surface, and leads to a differential Doppler shift of only a few 10s of Hz between the direct signal and the surface echo. As a consequence, this introduces ambiguity in the measurement of bandwidth and peak power of each surface echo. We report our interpretations of each surface echo in

  14. A new dawn for plant mitochondrial NAD(P)H dehydrogenases

    DEFF Research Database (Denmark)

    Møller, I.M.

    2002-01-01

    The expression of complex I and two homologues of bacterial and yeast NADH dehydrogenases, NDA and NDB, have been studied in potato leaf mitochondria. The mRNA level of NDA is completely light dependent and shows a diurnal rhythm with a sharp maximum just after dawn. NDA protein quantity and inte...

  15. Iron oxide minerals in dust of the Red Dawn event in eastern Australia, September 2009

    Science.gov (United States)

    Reynolds, Richard L.; Cattle, Stephen R.; Moskowitz, Bruce M.; Goldstein, Harland L.; Yauk, Kimberly; Flagg, Cody B.; Berquó, Thelma S.; Kokaly, Raymond F.; Morman, Suzette A.; Breit, George N.

    2014-01-01

    Iron oxide minerals typically compose only a few weight percent of bulk atmospheric dust but are important for potential roles in forcing climate, affecting cloud properties, influencing rates of snow and ice melt, and fertilizing marine phytoplankton. Dust samples collected from locations across eastern Australia (Lake Cowal, Orange, Hornsby, and Sydney) following the spectacular “Red Dawn” dust storm on 23 September 2009 enabled study of the dust iron oxide assemblage using a combination of magnetic measurements, Mössbauer spectroscopy, reflectance spectroscopy, and scanning electron microscopy. Red Dawn was the worst dust storm to have hit the city of Sydney in more than 60 years, and it also deposited dust into the Tasman Sea and onto snow cover in New Zealand. Magnetization measurements from 20 to 400 K reveal that hematite, goethite, and trace amounts of magnetite are present in all samples. Magnetite concentrations (as much as 0.29 wt%) were much higher in eastern, urban sites than in western, agricultural sites in central New South Wales (0.01 wt%), strongly suggesting addition of magnetite from local urban sources. Variable temperature Mössbauer spectroscopy (300 and 4.2 K) indicates that goethite and hematite compose approximately 25–45% of the Fe-bearing phases in samples from the inland sites of Orange and Lake Cowal. Hematite was observed at both temperatures but goethite only at 4.2 K, thereby revealing the presence of nanogoethite (less than about 20 nm). Similarly, hematite particulate matter is very small (some of it d < 100 nm) on the basis of magnetic results and Mössbauer spectra. The degree to which ferric oxide in these samples might absorb solar radiation is estimated by comparing reflectance values with a magnetic parameter (hard isothermal remanent magnetization, HIRM) for ferric oxide abundance. Average visible reflectance and HIRM are correlated as a group (r2 = 0.24), indicating that Red Dawn ferric oxides have

  16. Creating a safe place for pediatric care: A no hit zone.

    Science.gov (United States)

    Frazier, Erin R; Liu, Gilbert C; Dauk, Kelly L

    2014-07-01

    Our goal was to create and implement a program, Kosair Children's Hospital's No Hit Zone, which trains health care workers in de-escalation techniques to address parental disruptive behaviors and physical discipline of children commonly encountered in the hospital environment. The Child Abuse Task Force, a multidisciplinary group, along with key hospital administrators developed specific content for the policy, as well as marketing and educational materials. The No Hit Zone policy designates Kosair Children's Hospital as "an environment in which no adult shall hit a child, no adult shall hit another adult, no child shall hit an adult, and no child shall hit another child. When hitting is observed, it is everyone's responsibility to interrupt the behavior as well as communicate system policy to those present." Via a multidisciplinary, collaborative approach, the No Hit Zone was successfully implemented at Kosair Children's Hospital in 2012. Cost was nominal, and the support of key hospital administrators was critical to the program's success. Education of health professionals on de-escalation techniques and intervention with families at the early signs of parental stress occurred via live sessions and online training via case-based scenarios. The No Hit Zone is an important program used to provide a safe and caring environment for all families and staff of Kosair Children's Hospital. Demand for the program continues, demonstrated by the establishment of No Hit Zones at other local hospitals and multiple outpatient clinics. This article offers information for other organizations planning to conduct similar initiatives. Copyright © 2014 by the American Academy of Pediatrics.

  17. HIT and brain reward function: A case of mistaken identity (theory).

    Science.gov (United States)

    Wright, Cory; Colombo, Matteo; Beard, Alexander

    2017-08-01

    This paper employs a case study from the history of neuroscience-brain reward function-to scrutinize the inductive argument for the so-called 'Heuristic Identity Theory' (HIT). The case fails to support HIT, illustrating why other case studies previously thought to provide empirical support for HIT also fold under scrutiny. After distinguishing two different ways of understanding the types of identity claims presupposed by HIT and considering other conceptual problems, we conclude that HIT is not an alternative to the traditional identity theory so much as a relabeling of previously discussed strategies for mechanistic discovery. Copyright © 2017. Published by Elsevier Ltd.

  18. Calibration of the RPC charge readout in the ARGO-YBJ experiment

    Energy Technology Data Exchange (ETDEWEB)

    Aielli, G. [Dipartimento di Fisica dell& #x27; Universita & #x27; Tor Vergata& #x27; , via della Ricerca Scientifica 1, 00133 Roma (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Tor Vergata, via della Ricerca Scientifica 1, 00133 Roma (Italy); Bacci, C. [Dipartimento di Fisica dell& #x27; Universita & #x27; Roma Tre& #x27; , via della Vasca Navale 84, 00146 Roma (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Roma3, via della Vasca Navale 84, 00146 Roma (Italy); Bartoli, B. [Dipartimento di Fisica dell& #x27; Universita di Napoli, Complesso Universitario di Monte Sant& #x27; Angelo, via Cintia, 80126 Napoli (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Napoli, Complesso Universitario di Monte Sant& #x27; Angelo, via Cintia, 80126 Napoli (Italy); Bernardini, P. [Dipartimento di Fisica dell& #x27; Universita del Salento, via per Arnesano, 73100 Lecce (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Bi, X.J. [Key Laboratory of Particle Astrophyics, Institute of High Energy Physics, Chinese Academy of Science, P.O. Box 918, 100049 Beijing (China); Bleve, C. [Dipartimento di Fisica dell& #x27; Universita del Salento, via per Arnesano, 73100 Lecce (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Branchini, P.; Budano, A. [Istituto Nazionale di Fisica Nucleare, Sezione di Roma3, via della Vasca Navale 84, 00146 Roma (Italy); and others

    2012-01-01

    The charge readout of Resistive Plate Chambers (RPCs) is implemented in the ARGO-YBJ experiment to measure the charged particle density of the shower front up to 10{sup 4}/m{sup 2}, enabling the study of the primary cosmic rays with energies in the 'knee' region. As the first time for RPCs being used this way, a telescope with RPCs and scintillation detectors is setup to calibrate the number of charged particles hitting a RPC versus its charge readout. Air shower particles are taken as the calibration beam. The telescope was tested at sea level and then moved to the ARGO-YBJ site for coincident operation with the ARGO-YBJ experiment. The charge readout shows good linearity with the particle density in the dynamic range (up to 200/m{sup 2}).

  19. A combined hit theory-microdosimetric explanation of cellular radiobiological action

    International Nuclear Information System (INIS)

    Bond, V.P.; Varma, M.N.

    1983-01-01

    Hit theory is combined with microdosimetry in a stochastic approach that explains the observed responses of cell populations exposed in radiation fields of different qualities. The central thesis is that to expose a population of cells in a low-level radiation field is to subject the cells to the potential for interaction with charged particles, quantifiable in terms of the charged particle fluence PHI. When such an interaction occurs there is resulting stochastic transfer of energy to a critical volume (CV) of cross-section σ within the cell(s). The severity of cell injury is dependent on the amount of energy thus imparted, or the hit size. If the severity is above some minimal level, there is a non-zero probability that the injury will result in a quantal effect (e.g., a mutational or carcinogenic initial event, cell transformation). A microdosimetric proportional counter, viewed here as a phantom cell CV that permits measurements not possible in the living cell, is used to determine the incidence of hit cells and the spectrum of hit sizes. Each hit is then weighted on the basis of an empirically determined function that provides the fraction of cells responding quantally, as a function of hit size. The sum of the hits so weighted provides the incidence of quantally responding cells, for any amount of exposure PHI in a radiation field of any quality or mixture of qualities. The hit size weighting function for pink mutations in Tradescantia is discussed, as are its implications in terms of a replacement for relative biological effectiveness and dose equivalent. (author)

  20. PageRank, HITS and a unified framework for link analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Chris; He, Xiaofeng; Husbands, Parry; Zha, Hongyuan; Simon, Horst

    2001-10-01

    Two popular webpage ranking algorithms are HITS and PageRank. HITS emphasizes mutual reinforcement between authority and hub webpages, while PageRank emphasizes hyperlink weight normalization and web surfing based on random walk models. We systematically generalize/combine these concepts into a unified framework. The ranking framework contains a large algorithm space; HITS and PageRank are two extreme ends in this space. We study several normalized ranking algorithms which are intermediate between HITS and PageRank, and obtain closed-form solutions. We show that, to first order approximation, all ranking algorithms in this framework, including PageRank and HITS, lead to same ranking which is highly correlated with ranking by indegree. These results support the notion that in web resource ranking indegree and outdegree are of fundamental importance. Rankings of webgraphs of different sizes and queries are presented to illustrate our analysis.

  1. The dawn of freudism

    Directory of Open Access Journals (Sweden)

    Renato Barilli

    2013-02-01

    Full Text Available The author is a follower of the so called cultural materialism, which invites us to put the incoming of a new technology at the origin of each cultural age. A big rupture  arrived at the end of the 18th century, when scientists (as Galvani and Volta realized the first discoveries concerning electromagnetism. Such discoveries led to establish that matter is mainly energy, so opening a path which had to reach  the audacious conclusions due to Einstein’s relativism. But at the same time some writers and visual artists (Blake, Goethe, Alfieri, Foscolo, Leopardi discovered that a corresponding energy exists also into each of us. By this way they anticipated on a psychological level the intuitions  which should come from  Freud and his psychoanalisis. So we may conclude that at the end of i8th century there was a kind  of dawn both of technetronic era  and  of psychoanalysis.

  2. 76 FR 55914 - HIT Policy Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-09-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Policy Committee's Workgroups... standards, implementation specifications, and certification criteria are needed. Date and Time: The HIT...

  3. 76 FR 46297 - HIT Policy Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-08-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Policy Committee's Workgroups... standards, implementation specifications, and certification criteria are needed. Date and Time: The HIT...

  4. 76 FR 22399 - HIT Policy Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Policy Committee's Workgroups... standards, implementation specifications, and certification criteria are needed. Date and Time: The HIT...

  5. 76 FR 28784 - HIT Policy Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-05-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Policy Committee's Workgroups... standards, implementation specifications, and certification criteria are needed. Date and Time: The HIT...

  6. 75 FR 29762 - HIT Policy Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2010-05-27

    ... Technology HIT Policy Committee's Workgroup Meetings; Notice of Meetings AGENCY: Office of the National... only. Name of Committees: HIT Policy Committee's Workgroups: Meaningful Use, Privacy & Security Policy... specifications, and certification criteria are needed. Date and Time: The HIT Policy Committee Workgroups will...

  7. 76 FR 14974 - HIT Policy Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Policy Committee's Workgroups... standards, implementation specifications, and certification criteria are needed. Date and Time: The HIT...

  8. 76 FR 50735 - HIT Policy Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Policy Committee's Workgroups... standards, implementation specifications, and certification criteria are needed. Date and Time: The HIT...

  9. Verbs in the lexicon: Why is hitting easier than breaking?

    Science.gov (United States)

    McKoon, Gail; Love, Jessica

    2011-11-01

    Adult speakers use verbs in syntactically appropriate ways. For example, they know implicitly that the boy hit at the fence is acceptable but the boy broke at the fence is not. We suggest that this knowledge is lexically encoded in semantic decompositions. The decomposition for break verbs (e.g. crack, smash) is hypothesized to be more complex than that for hit verbs (e.g. kick, kiss). Specifically, the decomposition of a break verb denotes that "an entity changes state as the result of some external force" whereas the decomposition for a hit verb denotes only that "an entity potentially comes in contact with another entity." In this article, verbs of the two types were compared in a lexical decision experiment - Experiment 1 - and they were compared in sentence comprehension experiments with transitive sentences (e.g. the car hit the bicycle and the car broke the bicycle) - Experiments 2 and 3. In Experiment 1, processing times were shorter for the hit than the break verbs and in Experiments 2 and 3, processing times were shorter for the hit sentences than the break sentences, results that are in accord with the complexities of the postulated semantic decompositions.

  10. The highest-ranking rooster has priority to announce the break of dawn.

    Science.gov (United States)

    Shimmura, Tsuyoshi; Ohashi, Shosei; Yoshimura, Takashi

    2015-07-23

    The "cock-a-doodle-doo" crowing of roosters, which symbolizes the break of dawn in many cultures, is controlled by the circadian clock. When one rooster announces the break of dawn, others in the vicinity immediately follow. Chickens are highly social animals, and they develop a linear and fixed hierarchy in small groups. We found that when chickens were housed in small groups, the top-ranking rooster determined the timing of predawn crowing. Specifically, the top-ranking rooster always started to crow first, followed by its subordinates, in descending order of social rank. When the top-ranking rooster was physically removed from a group, the second-ranking rooster initiated crowing. The presence of a dominant rooster significantly reduced the number of predawn crows in subordinates. However, the number of crows induced by external stimuli was independent of social rank, confirming that subordinates have the ability to crow. Although the timing of subordinates' predawn crowing was strongly dependent on that of the top-ranking rooster, free-running periods of body temperature rhythms differed among individuals, and crowing rhythm did not entrain to a crowing sound stimulus. These results indicate that in a group situation, the top-ranking rooster has priority to announce the break of dawn, and that subordinate roosters are patient enough to wait for the top-ranking rooster's first crow every morning and thus compromise their circadian clock for social reasons.

  11. Mixed Hitting-Time Models

    NARCIS (Netherlands)

    Abbring, J.H.

    2009-01-01

    We study mixed hitting-time models, which specify durations as the first time a Levy process (a continuous-time process with stationary and independent increments) crosses a heterogeneous threshold. Such models of substantial interest because they can be reduced from optimal-stopping models with

  12. 76 FR 46298 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-08-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held virtually on August 17, 2011...

  13. 76 FR 50734 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on September 28, 2011, from 9...

  14. 77 FR 2727 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-01-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on February 29, 2012, from 9...

  15. 76 FR 70455 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-11-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on December 14, 2011, from 9...

  16. 75 FR 5595 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2010-02-03

    ... Technology HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National... Health Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT... Federal Health IT Strategic Plan, and in accordance with policies developed by the HIT Policy Committee...

  17. 77 FR 73661 - HIT Standards Committee Advisory Meetings; Notice of Meetings

    Science.gov (United States)

    2012-12-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meetings; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: These meetings will be held on the following dates and...

  18. 76 FR 70454 - HIT Policy Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-11-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Policy Committee's Workgroups... certification criteria are needed. Date and Time: The HIT Policy Committee Workgroups will hold the following...

  19. 76 FR 28784 - HIT Standards Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-05-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Standards Committee's... implementation of the Federal Health IT Strategic Plan, and in accordance with policies developed by the HIT...

  20. 76 FR 50736 - HIT Standards Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Standards Committee's... implementation of the Federal Health IT Strategic Plan, and in accordance with policies developed by the HIT...

  1. 76 FR 14975 - HIT Standards Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee's Workgroup Meetings; Notice of... be open to the public via dial-in access only. Name of Committees: HIT Standards Committee's... implementation of the Federal Health IT Strategic Plan, and in accordance with policies developed by the HIT...

  2. 77 FR 65691 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-10-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on November 13, 2012, from 9...

  3. 77 FR 50690 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-08-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on September 19, 2012, from 9...

  4. 75 FR 21628 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2010-04-26

    ... Technology HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards... Strategic Plan, and in accordance with policies developed by the HIT Policy Committee. Date and Time: The...

  5. 76 FR 55913 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-09-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held virtually on October 21, 2011...

  6. 77 FR 65690 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-10-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on December 19, 2012, from 9...

  7. Single-hit mechanism of tumour cell killing by radiation.

    Science.gov (United States)

    Chapman, J D

    2003-02-01

    To review the relative importance of the single-hit mechanism of radiation killing for tumour response to 1.8-2.0 Gy day(-1) fractions and to low dose-rate brachytherapy. Tumour cell killing by ionizing radiation is well described by the linear-quadratic equation that contains two independent components distinguished by dose kinetics. Analyses of tumour cell survival curves that contain six or more dose points usually provide good estimates of the alpha- and beta-inactivation coefficients. Superior estimates of tumour cell intrinsic radiosensitivity are obtained when synchronized populations are employed. The characteristics of single-hit inactivation of tumour cells are reviewed and compared with the characteristics of beta-inactivation. Potential molecular targets associated with single-hit inactivation are discussed along with strategies for potentiating cell killing by this mechanism. The single-hit mechanism of tumour cell killing shows no dependence on dose-rate and, consequently, no evidence of sublethal damage repair. It is uniquely potentiated by high linear-energy-transfer radiation, exhibits a smaller oxygen enhancement ratio and exhibits a larger indirect effect by hydroxyl radicals than the beta-mechanism. alpha-inactivation coefficients vary slightly throughout interphase but mitotic cells exhibit extremely high alpha-coefficients in the range of those observed for lymphocytes and some repair-deficient cells. Evidence is accumulating to suggest that chromatin in compacted form could be a radiation-hypersensitive target associated with single-hit radiation killing. Analyses of tumour cell survival curves demonstrate that it is the single-hit mechanism (alpha) that determines the majority of cell killing after doses of 2Gy and that this mechanism is highly variable between tumour cell lines. The characteristics of single-hit inactivation are qualitatively and quantitatively distinct from those of beta-inactivation. Compacted chromatin in tumour cells

  8. Assessing the lipophilicity of fragments and early hits

    Science.gov (United States)

    Mortenson, Paul N.; Murray, Christopher W.

    2011-07-01

    A key challenge in many drug discovery programs is to accurately assess the potential value of screening hits. This is particularly true in fragment-based drug design (FBDD), where the hits often bind relatively weakly, but are correspondingly small. Ligand efficiency (LE) considers both the potency and the size of the molecule, and enables us to estimate whether or not an initial hit is likely to be optimisable to a potent, druglike lead. While size is a key property that needs to be controlled in a small molecule drug, there are a number of additional properties that should also be considered. Lipophilicity is amongst the most important of these additional properties, and here we present a new efficiency index (LLEAT) that combines lipophilicity, size and potency. The index is intuitively defined, and has been designed to have the same target value and dynamic range as LE, making it easily interpretable by medicinal chemists. Monitoring both LE and LLEAT should help both in the selection of more promising fragment hits, and controlling molecular weight and lipophilicity during optimisation.

  9. 77 FR 16035 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-03-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on March 27, 2012, from 9 a.m...

  10. 76 FR 79684 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-12-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on January 25, 2012, from 9 a...

  11. 77 FR 15760 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on April 18, 2012, from 9 a.m...

  12. 76 FR 14976 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on April 20, 2011, from 9 a.m...

  13. 76 FR 39109 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-07-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on July 20, 2011, from 9 a.m...

  14. 76 FR 28782 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-05-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on June 22, 2011, from 9 a.m...

  15. 77 FR 27459 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-05-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on June 20, 2012, from 9 a.m...

  16. 77 FR 37408 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-06-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... be open to the public. Name of Committee: HIT Standards Committee. General Function of the Committee... with policies developed by the HIT Policy Committee. Date and Time: The meeting will be held on July 19...

  17. 77 FR 22787 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-04-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on May 24, 2012, from 9 a.m...

  18. 76 FR 22396 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: to provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on May 18, 2011, from 9 a.m...

  19. 77 FR 60438 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-10-03

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on October 17, 2012, from 9 a...

  20. 76 FR 9783 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-02-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on March 29, 2011, from 9 a.m...

  1. 77 FR 45353 - HIT Standards Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-07-31

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee Advisory Meeting; Notice of... public. Name of Committee: HIT Standards Committee. General Function of the Committee: To provide... developed by the HIT Policy Committee. Date and Time: The meeting will be held on August 15, 2012, from 9:00...

  2. MD#2183: Calibration of the IR6 B2 diamond BLMs

    CERN Document Server

    Valette, Matthieu; Lindstrom, Bjorn Hans Filip

    2018-01-01

    In case of an asynchronous beam dump with a fully filled LHC machine, causing ~40 bunches to impact on the movable dump protection absorber (TCDQ), it is expected that all standard ionisation chamber Beam Loss Monitors (IC BLM) around the LHC dumping region in IR6 will be saturated. Diamond Beam Loss Monitors (dBLM) were therefore installed next to the TCDQ downstream of the extraction kickers. These detectors allow resolving losses at a nanosecond timescale and with a dynamic range of several orders of magnitude; thus, allowing to derive the number of nominal bunches impacting the TCDQ. After a first series of calibrations using asynchronous beam dump tests, an experiment was conducted during MD#1182 to demonstrate the possibility of resolving a nominal bunch hitting the TCDQ. During this first MD only the Beam 1 dBLM was calibrated appropriately, a second calibration MD was therefore performed in 2017 for the B2 system. Results from this MD and conclusions regarding dBLM saturation with a top energy nominal...

  3. A C++ object-oriented toolkit for track finding with k-dimensional hits

    International Nuclear Information System (INIS)

    Uiterwijk, J.W.E.; Panman, J.; Vyver, B. van de

    2006-01-01

    A library is described for the recognition of tracks in a set of hits. The hits are assumed to be k-dimensional points (k-d), with k>=1, of which a subset can be grouped into tracks by using short-range correlations. A connection graph between the hits is created by sorting the hits first in k-d space using one of the developed, fast, k-space containers. The track-finding algorithm considers any connection between two hits as a possible track seed and grows these seeds into longer track segments using a modified depth-first search of the connection graph. All hit-acceptance decisions are called via abstract methods of an acceptance criterion class which isolates the library from the application's hit and track model. An application is tuned for a particular tracking environment by creating a concrete implementation for the hit and track acceptance calculations. The implementer is free to trade tracking time for acceptance complexity (influencing efficiency) depending on the requirements of the particular application. Results for simulated data show that the track finding is both efficient and fast even for high noise environments

  4. Nature of the "Orange" Material on Vesta From Dawn

    Science.gov (United States)

    LeCorre, L.; Reddy, V.; Schmedemann, N.; Becker, K. J.; OBrien, D. P.; Yamashita, N.; Peplowski, P. N.; Prettyman, T. H.; Li, J.-Y.; Coultis, E. A.; hide

    2014-01-01

    From ground-based observations of Vesta, it is well-known that the vestan surface has a large variation in albedo. Analysis of images acquired by the Hubble Space Telescope allowed production of the first color maps of Vesta and showed a diverse surface in terms of reflectance. Thanks to images collected by the Dawn spacecraft at Vesta, it became obvious that these specific units observed previously can be linked to geological features. The presence of the darkest material mostly around impact craters and scattered in the Western hemisphere has been associated with carbonaceous chondrite contamination [4]; whereas the brightest materials are believed to result from exposure of unaltered material from the subsurface of Vesta (in fresh looking impact crater rims and in Rheasilvia's ejecta and rim remants). Here we focus on a distinct material characterized by a steep slope in the near-IR relative to all other kinds of materials found on Vesta. It was first detected when combining Dawn Framing Camera (FC) color images in Clementine false-color composites [5] during the Approach phase of the mission (100000 to 5200 km from Vesta). We investigate the mineralogical and elemental composition of this material and its relationship with the HEDs (Howardite-Eucrite- Diogenite group of meteorites).

  5. Zero to Integration in Eight Months, the Dawn Ground Data System Engineering Challange

    Science.gov (United States)

    Dubon, Lydia P.

    2006-01-01

    The Dawn Project has presented the Ground Data System (GDS) with technical challenges driven by cost and schedule constraints commonly associated with National Aeronautics and Space Administration (NASA) Discovery Projects. The Dawn mission consists of a new and exciting Deep Space partnership among: the Jet Propulsion Laboratory (JPL), responsible for project management and flight operations; Orbital Sciences Corporation (OSC), spacecraft builder and responsible for flight system test and integration; and the University of California, at Los Angeles (UCLA), responsible for science planning and operations. As a cost-capped mission, one of Dawn s implementation strategies is to leverage from both flight and ground heritage. OSC's ground data system is used for flight system test and integration as part of the flight heritage strategy. Mission operations, however, are to be conducted with JPL s ground system. The system engineering challenge of dealing with two heterogeneous ground systems emerged immediately. During the first technical interchange meeting between the JPL s GDS Team and OSC's Flight Software Team, August 2003, the need to integrate the ground system with the flight software was brought to the table. This need was driven by the project s commitment to enable instrument engineering model integration in a spacecraft simulator environment, for both demonstration and risk mitigation purposes, by April 2004. This paper will describe the system engineering approach that was undertaken by JPL's GDS Team in order to meet the technical challenge within a non-negotiable eight-month schedule. Key to the success was adherence to an overall systems engineering process and fundamental systems engineering practices: decomposition of the project request into manageable requirements; definition of a structured yet flexible development process; integration of multiple ground disciplines and experts into a focused team effort; in-process risk management; and aggregation

  6. Throat hit in users of the electronic cigarette: An exploratory study.

    Science.gov (United States)

    Etter, Jean-François

    2016-02-01

    A cross-sectional survey on the Internet in 2012-2014 was used to study the "throat hit," the specific sensation in the throat felt by users of e-cigarettes. Participants were 1672 current users of e-cigarettes, visitors of Websites dedicated to e-cigarettes and to smoking cessation. It was assessed whether the strength of the throat hit was associated with the characteristics of e-cigarettes and e-liquids, modifications of the devices, patterns of use, reasons for use, satisfaction with e-cigarettes, dependence on e-cigarettes, smoking behavior, and perceived effects on smoking. The strongest throat hit was obtained by using better-quality models and liquids with high nicotine content. Those who reported a "very strong" throat hit used liquids with 17.3 mg/mL nicotine, versus 7.1 mg/mL for those reporting a "very weak" hit (p e-cigarette models that provide high levels of nicotine, a strong throat hit, high satisfaction, and more effects on smoking, but may also be addictive, and models than contain less nicotine and are less addictive, but produce a weaker throat hit, are less satisfactory, and are possibly less efficient at helping people quit smoking. This trade-off must be kept in mind when regulating e-cigarettes. (c) 2016 APA, all rights reserved).

  7. Identifying and Synchronizing Health Information Technology (HIT) Events from FDA Medical Device Reports.

    Science.gov (United States)

    Kang, Hong; Wang, Frank; Zhou, Sicheng; Miao, Qi; Gong, Yang

    2017-01-01

    Health information technology (HIT) events, a subtype of patient safety events, pose a major threat and barrier toward a safer healthcare system. It is crucial to gain a better understanding of the nature of the errors and adverse events caused by current HIT systems. The scarcity of HIT event-exclusive databases and event reporting systems indicates the challenge of identifying the HIT events from existing resources. FDA Manufacturer and User Facility Device Experience (MAUDE) database is a potential resource for HIT events. However, the low proportion and the rapid evolvement of HIT-related events present challenges for distinguishing them from other equipment failures and hazards. We proposed a strategy to identify and synchronize HIT events from MAUDE by using a filter based on structured features and classifiers based on unstructured features. The strategy will help us develop and grow an HIT event-exclusive database, keeping pace with updates to MAUDE toward shared learning.

  8. Light pollution alters the phenology of dawn and dusk singing in common European songbirds.

    Science.gov (United States)

    Da Silva, Arnaud; Valcu, Mihai; Kempenaers, Bart

    2015-05-05

    Artificial night lighting is expanding globally, but its ecological consequences remain little understood. Animals often use changes in day length as a cue to time seasonal behaviour. Artificial night lighting may influence the perception of day length, and may thus affect both circadian and circannual rhythms. Over a 3.5 month period, from winter to breeding, we recorded daily singing activity of six common songbird species in 12 woodland sites, half of which were affected by street lighting. We previously reported on analyses suggesting that artificial night lighting affects the daily timing of singing in five species. The main aim of this study was to investigate whether the presence of artificial night lighting is also associated with the seasonal occurrence of dawn and dusk singing. We found that in four species dawn and dusk singing developed earlier in the year at sites exposed to light pollution. We also examined the effects of weather conditions and found that rain and low temperatures negatively affected the occurrence of dawn and dusk singing. Our results support the hypothesis that artificial night lighting alters natural seasonal rhythms, independently of other effects of urbanization. The fitness consequences of the observed changes in seasonal timing of behaviour remain unknown.

  9. High energy ion hit technique to local area using microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Ryuichi; Kamiya, Tomihiro; Suda, Tamotsu; Sakai, Takuro; Hirao, Toshio; Kobayashi, Yasuhiko; Watanabe, Hiroshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    Single energetic ion hit technique has been developed as an application of ion microbeam technique, in order to study the effect of local damage or injury to materials and living organisms. The overall performance is basically defined by those of separate techniques: microbeam formation, microbeam positioning, single ion detection, detection signal processing, hit timing control, and hit verification. Recent progress on the developments of these techniques at JAERI-TIARA facility are reviewed. (author)

  10. Database for High Throughput Screening Hits (dHITS): a simple tool to retrieve gene specific phenotypes from systematic screens done in yeast.

    Science.gov (United States)

    Chuartzman, Silvia G; Schuldiner, Maya

    2018-03-25

    In the last decade several collections of Saccharomyces cerevisiae yeast strains have been created. In these collections every gene is modified in a similar manner such as by a deletion or the addition of a protein tag. Such libraries have enabled a diversity of systematic screens, giving rise to large amounts of information regarding gene functions. However, often papers describing such screens focus on a single gene or a small set of genes and all other loci affecting the phenotype of choice ('hits') are only mentioned in tables that are provided as supplementary material and are often hard to retrieve or search. To help unify and make such data accessible, we have created a Database of High Throughput Screening Hits (dHITS). The dHITS database enables information to be obtained about screens in which genes of interest were found as well as the other genes that came up in that screen - all in a readily accessible and downloadable format. The ability to query large lists of genes at the same time provides a platform to easily analyse hits obtained from transcriptional analyses or other screens. We hope that this platform will serve as a tool to facilitate investigation of protein functions to the yeast community. © 2018 The Authors Yeast Published by John Wiley & Sons Ltd.

  11. All hypertopologies are hit-and-miss

    Directory of Open Access Journals (Sweden)

    Somshekhar Naimpally

    2002-04-01

    Full Text Available We solve a long standing problem by showing that all known hypertopologies are hit-and-miss. Our solution is not merely of theoretical importance. This representation is useful in the study of comparison of the Hausdorff-Bourbaki or H-B uniform topologies and the Wijsman topologies among themselves and with others. Up to now some of these comparisons needed intricate manipulations. The H-B uniform topologies were the subject of intense activity in the 1960's in connection with the Isbell-Smith problem. We show that they are proximally locally finite topologies from which the solution to the above problem follows easily. It is known that the Wijsman topology on the hyperspace is the proximal ball (hit-and-miss topology in”nice” metric spaces including the normed linear spaces. With the introduction of a new far-miss topology we show that the Wijsman topology is hit-and-miss for all metric spaces. From this follows a natural generalization of the Wijsman topology to the hyperspace of any T1 space. Several existing results in the literature are easy consequences of our work.

  12. Cosmic Ray Hit Detection with Homogenous Structures

    Science.gov (United States)

    Smirnov, O. M.

    Cosmic ray (CR) hits can affect a significant number of pixels both on long-exposure ground-based CCD observations and on the Space Telescope frames. Thus, methods of identifying the damaged pixels are an important part of the data preprocessing for practically any application. The paper presents an implementation of a CR hit detection algorithm based on a homogenous structure (also called cellular automata ), a concept originating in artificial intelligence and dicrete mathematics. Each pixel of the image is represented by a small automaton, which interacts with its neighbors and assumes a distinct state if it ``decides'' that a CR hit is present. On test data, the algorithm has shown a high detection rate (~0.7 ) and a low false alarm rate (frame. A homogenous structure is extremely trainable, which can be very important for processing large batches of data obtained under similar conditions. Training and optimizing issues are discussed, as well as possible other applications of this concept to image processing.

  13. Use of Cumulative Degradation Factor Prediction and Life Test Result of the Thruster Gimbal Assembly Actuator for the Dawn Flight Project

    Science.gov (United States)

    Lo, C. John; Brophy, John R.; Etters, M. Andy; Ramesham, Rajeshuni; Jones, William R., Jr.; Jansen, Mark J.

    2009-01-01

    The Dawn Ion Propulsion System is the ninth project in NASA s Discovery Program. The Dawn spacecraft is being developed to enable the scientific investigation of the two heaviest main-belt asteroids, Vesta and Ceres. Dawn is the first mission to orbit two extraterrestrial bodies, and the first to orbit a main-belt asteroid. The mission is enabled by the onboard Ion Propulsion System (IPS) to provide the post-launch delta-V. The three Ion Engines of the IPS are mounted on Thruster Gimbal Assembly (TGA), with only one engine operating at a time for this 10-year mission. The three TGAs weigh 14.6 kg.

  14. The dawn of gravitational wave astronomy

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    On Sep 14 2015, gravitational waves were for the first time detected directly. This observation by the LIGO interferometric detectors marks the dawn of a new era in our observational study of the cosmos as a qualitatively new window to its exploration has been opened. This talk reviews some of the fundamental concepts of gravitational waves and the methodology employed for their observation. The first event, dubbed GW150914, and the properties of its source, as inferred from the observation, will be discussed. The talk concludes with a selected set of the most important topics where we expect gravitational-wave observations to deepen and either challenge or confirm our present understanding of the laws and the history of our universe.

  15. SARAS 2: a spectral radiometer for probing cosmic dawn and the epoch of reionization through detection of the global 21-cm signal

    Science.gov (United States)

    Singh, Saurabh; Subrahmanyan, Ravi; Shankar, N. Udaya; Rao, Mayuri Sathyanarayana; Girish, B. S.; Raghunathan, A.; Somashekar, R.; Srivani, K. S.

    2018-04-01

    The global 21-cm signal from Cosmic Dawn (CD) and the Epoch of Reionization (EoR), at redshifts z ˜ 6-30, probes the nature of first sources of radiation as well as physics of the Inter-Galactic Medium (IGM). Given that the signal is predicted to be extremely weak, of wide fractional bandwidth, and lies in a frequency range that is dominated by Galactic and Extragalactic foregrounds as well as Radio Frequency Interference, detection of the signal is a daunting task. Critical to the experiment is the manner in which the sky signal is represented through the instrument. It is of utmost importance to design a system whose spectral bandpass and additive spurious signals can be well calibrated and any calibration residual does not mimic the signal. Shaped Antenna measurement of the background RAdio Spectrum (SARAS) is an ongoing experiment that aims to detect the global 21-cm signal. Here we present the design philosophy of the SARAS 2 system and discuss its performance and limitations based on laboratory and field measurements. Laboratory tests with the antenna replaced with a variety of terminations, including a network model for the antenna impedance, show that the gain calibration and modeling of internal additive signals leave no residuals with Fourier amplitudes exceeding 2 mK, or residual Gaussians of 25 MHz width with amplitudes exceeding 2 mK. Thus, even accounting for reflection and radiation efficiency losses in the antenna, the SARAS 2 system is capable of detection of complex 21-cm profiles at the level predicted by currently favoured models for thermal baryon evolution.

  16. The prehistory of potyviruses: their initial radiation was during the dawn of agriculture.

    Science.gov (United States)

    Gibbs, Adrian J; Ohshima, Kazusato; Phillips, Matthew J; Gibbs, Mark J

    2008-06-25

    Potyviruses are found world wide, are spread by probing aphids and cause considerable crop damage. Potyvirus is one of the two largest plant virus genera and contains about 15% of all named plant virus species. When and why did the potyviruses become so numerous? Here we answer the first question and discuss the other. We have inferred the phylogenies of the partial coat protein gene sequences of about 50 potyviruses, and studied in detail the phylogenies of some using various methods and evolutionary models. Their phylogenies have been calibrated using historical isolation and outbreak events: the plum pox virus epidemic which swept through Europe in the 20th century, incursions of potyviruses into Australia after agriculture was established by European colonists, the likely transport of cowpea aphid-borne mosaic virus in cowpea seed from Africa to the Americas with the 16th century slave trade and the similar transport of papaya ringspot virus from India to the Americas. Our studies indicate that the partial coat protein genes of potyviruses have an evolutionary rate of about 1.15x10(-4) nucleotide substitutions/site/year, and the initial radiation of the potyviruses occurred only about 6,600 years ago, and hence coincided with the dawn of agriculture. We discuss the ways in which agriculture may have triggered the prehistoric emergence of potyviruses and fostered their speciation.

  17. A fast DSP-based calorimeter hit scanning system

    International Nuclear Information System (INIS)

    Sekikawa, S.; Arai, I.; Suzuki, A.; Watanabe, A.; Marlow, D.R.; Mindas, C.R.; Wixted, R.L.

    1997-01-01

    A custom made digital signal processor (DSP) based system has been developed to scan calorimeter hits read by a 32-channel FASTBUS waveform recorder board. The scanner system identifies hit calorimeter elements by surveying their discriminated outputs. This information is used to generate a list of addresses, which guides the read-out process. The system is described and measurements of the scan times are given. (orig.)

  18. Dawn- Dusk Auroral Oval Oscillations Associated with High- Speed Solar Wind

    Science.gov (United States)

    Liou, Kan; Sibeck, David G.

    2018-01-01

    We report evidence of global-scale auroral oval oscillations in the millihertz range, using global auroral images acquired from the Ultraviolet Imager on board the decommissioned Polar satellite and concurrent solar wind measurements. On the basis of two events (15 January 1999 and 6 January 2000) studied, it is found that (1) quasi-periodic auroral oval oscillations (approximately 3 megahertz) can occur when solar wind speeds are high at northward or southward interplanetary magnetic field turning, (2) the oscillation amplitudes range from a few to more than 10 degrees in latitudes, (3) the oscillation frequency is the same for each event irrespective of local time and without any azimuthal phase shift (i.e., propagation), (4) the auroral oscillations occur in phase within both the dawn and dusk sectors but 180 degrees out of phase between the dawn and dusk sectors, and (5) no micropulsations on the ground match the auroral oscillation periods. While solar wind conditions favor the growth of the Kelvin-Helmholtz (K-H) instability on the magnetopause as often suggested, the observed wave characteristics are not consistent with predictions for K-H waves. The in-phase and out-of-phase features found in the dawn-dusk auroral oval oscillations suggest that wiggling motions of the magnetotail associated with fast solar winds might be the direct cause of the global-scale millihertz auroral oval oscillations. Plain Language Summary: We utilize global auroral image data to infer the motion of the magnetosphere and show, for the first time, the entire magnetospheric tail can move east-west in harmony like a windsock flapping in wind. The characteristic period of the flapping motion may be a major source of global long-period ULF (Ultra Low Frequency) waves, adding an extra source of the global mode ULF waves.

  19. Simultaneous alignment and Lorentz angle calibration in the CMS silicon tracker using Millepede II

    CERN Document Server

    Bartosik, Nazar

    2013-01-01

    The CMS silicon tracker consists of 25 684 sensors that provide measurements of trajectories of charged particles that are used by almost every physics analysis at CMS. In order to achieve high measurement precision, the positions and orientations of all sensors have to be determined very accurately. This is achieved by track-based alignment using the global fit approach of the Millepede II program. This approach is capable of determining about 200 000 parameters simultaneously.The alignment precision reached such a high level that even small calibration inaccuracies are noticeable. Therefore the alignment framework has been extended to treat position sensitive calibration parameters. Of special interest is the Lorentz angle which affects the hit positions due to the drift of the signal electrons in the magnetic field. We present the results from measurements of the Lorentz angle and its time dependence during full 2012 data taking period as well as general description of the alignment and calibration procedu...

  20. In-flight calibration system for the INTEGRAL x-ray monitor

    DEFF Research Database (Denmark)

    Costa, E.; Feroci, M.; Barbanera, L.

    1996-01-01

    of Amptek Cool-X15 X-ray generators. The latter is a novel product, based on a pyroelectric crystal used to generate energetic electrons that produce fluorescence lines by hitting a metallic target. We plan to use the four low intensity radioactive sources for monitoring the four independent anode chains......JEM-X is the x-ray monitor serving the two gamma-ray experiments imager and spectrometer onboard the ESA's INTEGRAL satellite. Due to the intrinsic weakness of the celestial sources in the gamma energy range they will need very long integration times. During these long pointings JEM-X will be able...... to detect very small variations on most x-ray sources, but only if accurately calibrated. The in- flight calibration system of the JEM-X experiment is devoted to measure the response of the detection chain (detector plus electronics) in a small set of positions and energies. The data from this system...

  1. In-Flight Operation of the Dawn Ion Propulsion System: Status at One Year from the Vesta Rendezvous

    Science.gov (United States)

    Garner, Charles E.; Rayman, Marc D.

    2010-01-01

    The Dawn mission, part of NASA's Discovery Program, has as its goal the scientific exploration of the two most massive main-belt asteroids, Vesta and Ceres. The Dawn spacecraft was launched from Cape Canaveral Air Force Station on September 27, 2007 on a Delta-II 7925H-9.5 (Delta-II Heavy) rocket that placed the 1218 kg spacecraft into an Earth-escape trajectory. On-board the spacecraft is an ion propulsion system (IPS) developed at the Jet Propulsion Laboratory which will provide most of the delta V needed for heliocentric transfer to Vesta, orbit capture at Vesta, transfer among Vesta science orbits, departure and escape from Vesta, heliocentric transfer to Ceres, orbit capture at Ceres, and transfer among Ceres science orbits. The Dawn ion thruster [I thought we only called it a thruster. Both terms are used in the paper, but I think a replacement of every occurrence of "engine" with "thruster" would be clearer.] design is based on the design validated on NASA's Deep Space 1 (DS1) mission. However, because of the very substantial (11 km/s) delta V requirements for this mission Dawn requires two engines to complete its mission objectives. The power processor units (PPU), digital control and interface units (DCIU) slice boards and the xenon control assembly (XCA) are derivatives of the components used on DS1. The DCIUs and thrust gimbal assemblies (TGA) were developed at the Jet Propulsion Laboratory. The spacecraft was provided by Orbital Sciences Corporation, Sterling, Virginia, and the mission is managed by and operated from the Jet Propulsion Laboratory. Dawn partnered with Germany, Italy and Los Alamos National Laboratory for the science instruments. The mission is led by the principal investigator, Dr. Christopher Russell, from the University of California, Los Angeles. The first 80 days after launch were dedicated to the initial checkout of the spacecraft followed by cruise to Mars. Cruise thrusting leading to a Mars gravity assist began on December 17

  2. Preliminary Results from Initial Investigations of Ceres' Cratering Record from Dawn Imaging Data

    Science.gov (United States)

    Schmedemann, Nico; Michael, Gregory; Ivanov, Boris A.; Kneissl, Thomas; Neesemann, Adrian; Hiesinger, Harald; Jaumann, Ralf; Raymond, Carol A.; Russell, Christopher T.

    2015-04-01

    The highly successful Dawn mission [1] finished data collection at Vesta in 2012 and is now on its way to the dwarf planet Ceres. According to the current Ceres approach timeline of the Dawn mission, the ground resolution of the Dawn FC camera [2] will be about 10 times better than Hubble data [3] at the time of the presentation of this work. This may allow for identification of craters about 15 km in diameter. Initial mapping of sample areas may provide enough information of the cratering record in order to compare it with the theoretical Ceres crater production function we present at the 46th LPSC conference (March 16-20, 2015, The Woodlands, Texas) [4]. Our preliminary crater production function for Ceres is derived from the assumption of an icy crust just below a thin surface layer of dust [5], and a projectile population that is very similar to the one that impacted the Moon [6]. In order to scale the lunar cratering record to Ceres we use the Ivanov scaling laws [7], which allow for crater scaling based on parameters that can be derived from observations. The lunar-like approach gave reasonable good results for the crater production function on the asteroids Vesta, Ida, Lutetia and Gaspra [8]. Since the lunar surface is of basaltic composition, the correct scaling between the different materials is challenging. One crucial parameter is the transition diameter from simple to complex craters. Based on the simple to complex transition diameter on Iapetus, an icy satellite of Saturn, we expect this transition at about 12 km crater size at Ceres. This value may be slightly different due to the different temperatures at Ceres and Iapetus. If the simple to complex transition is observed at much larger diameters, the reason could be a substantial fraction of rock in the shallow subsurface of Ceres. In an ice-rich surface material high relaxation rates may also be expected that could change the shape of the crater production function. A thorough geological mapping

  3. Cultural Appropriation in Games : A Comparative Study Between Far Cry 3 (2012), Overwatch (2016) and Horizon Zero Dawn (2017)

    OpenAIRE

    Svensson, Tova

    2017-01-01

    This thesis is a comparative study between Far Cry 3 (2012), Overwatch (2016) and Horizon Zero Dawn (2017) to determine how game developers appropriate minority cultures in character design. The character designs are compared to the cultures of origin to determine whether they have been appropriated and to what extent. Far Cry 3 appropriates Maori and Samoan cultures, Horizon Zero Dawn appropriates native American cultures, and Overwatch appropriates both Maori and native American cultures. A...

  4. First observations of Ceres by VIR on Dawn mission

    Science.gov (United States)

    De Sanctis, M. Cristina; Ammannito, Eleonora; Fonte, Sergio; Magni, Gianfranco; Capaccioni, Fabrizio; Capria, M. Teresa; Raymond, Carol. A.; Russell, Christopher T.

    2015-04-01

    The Dawn spacecraft [1] is now approaching Ceres, the second of its targets. Ceres represents the key to understand some important points relative to the role of the protoplanet size and the water content in the evolution of these bodies. Ceres is thought to be differentiated, and hydrated minerals were proposed to exist on its surface [2,3,4]. Its low density [3] associated with the presence of transient water vapour, suggests a high content of ice inside the body and on its surface. Ceres seems to have been subject to differentiation and hydrothermal activity, and might host a liquid subsurface layer even today. Dawn is equipped with a Visible and InfraRed Mapping Spectrometer (VIR-MS) [5]. VIR-MS is an imaging spectrometer coupling high spectral and spatial resolution in the VIS (0.25-1 micron) and IR (0.95-5 micron) spectral ranges. The surface composition of Ceres is poorly understood through its nearly featureless visible spectrum. Its visible reflectance spectrum has a steep UV absorption edge that begins at a relatively short wavelength, around 0.4 micron, unlike many C-type asteroids where the UV drop-off begins around 0.6 to 0.7 micron[6]. The near-IR spectrum has a strong absorption band centered at about 3-micron. The absorption features in the 3-micron region were attributed to structural water in clay minerals [7,8] but could also be ammoniated clays [9]. [10] reported the discovery of carbonates and iron-rich clays from measurements of weak 3-micron features, and the results are consistent with the mid-IR spectra of clay minerals. On approach to Ceres, Dawn will obtain images and hyperspectral . VIR data, with resolution larger than Hubble images will reveal the first details of the Ceres' surface composition. Here we report about the first data obtained by VIR during its approach to Ceres. Acknowledgments VIR is funded by the Italian Space Agency-ASI and was developed under the leadership of INAF-Istituto di Astrofisica e Planetologia Spaziali, Rome

  5. "Hit-and-Run" leaves its mark: catalyst transcription factors and chromatin modification.

    Science.gov (United States)

    Varala, Kranthi; Li, Ying; Marshall-Colón, Amy; Para, Alessia; Coruzzi, Gloria M

    2015-08-01

    Understanding how transcription factor (TF) binding is related to gene regulation is a moving target. We recently uncovered genome-wide evidence for a "Hit-and-Run" model of transcription. In this model, a master TF "hits" a target promoter to initiate a rapid response to a signal. As the "hit" is transient, the model invokes recruitment of partner TFs to sustain transcription over time. Following the "run", the master TF "hits" other targets to propagate the response genome-wide. As such, a TF may act as a "catalyst" to mount a broad and acute response in cells that first sense the signal, while the recruited TF partners promote long-term adaptive behavior in the whole organism. This "Hit-and-Run" model likely has broad relevance, as TF perturbation studies across eukaryotes show small overlaps between TF-regulated and TF-bound genes, implicating transient TF-target binding. Here, we explore this "Hit-and-Run" model to suggest molecular mechanisms and its biological relevance. © 2015 The Authors. Bioessays published by WILEY Periodicals, Inc.

  6. The Square Kilometre Array Epoch of Reionisation and Cosmic Dawn Experiment

    Science.gov (United States)

    Trott, Cathryn M.

    2018-05-01

    The Square Kilometre Array (SKA) Epoch of Reionisation and Cosmic Dawn (EoR/CD) experiments aim to explore the growth of structure and production of ionising radiation in the first billion years of the Universe. Here I describe the experiments planned for the future low-frequency components of the Observatory, and work underway to define, design and execute these programs.

  7. Hit Identification and Optimization in Virtual Screening: Practical Recommendations Based Upon a Critical Literature Analysis

    Science.gov (United States)

    Zhu, Tian; Cao, Shuyi; Su, Pin-Chih; Patel, Ram; Shah, Darshan; Chokshi, Heta B.; Szukala, Richard; Johnson, Michael E.; Hevener, Kirk E.

    2013-01-01

    A critical analysis of virtual screening results published between 2007 and 2011 was performed. The activity of reported hit compounds from over 400 studies was compared to their hit identification criteria. Hit rates and ligand efficiencies were calculated to assist in these analyses and the results were compared with factors such as the size of the virtual library and the number of compounds tested. A series of promiscuity, drug-like, and ADMET filters were applied to the reported hits to assess the quality of compounds reported and a careful analysis of a subset of the studies which presented hit optimization was performed. This data allowed us to make several practical recommendations with respect to selection of compounds for experimental testing, defining hit identification criteria, and general virtual screening hit criteria to allow for realistic hit optimization. A key recommendation is the use of size-targeted ligand efficiency values as hit identification criteria. PMID:23688234

  8. Hit identification and optimization in virtual screening: practical recommendations based on a critical literature analysis.

    Science.gov (United States)

    Zhu, Tian; Cao, Shuyi; Su, Pin-Chih; Patel, Ram; Shah, Darshan; Chokshi, Heta B; Szukala, Richard; Johnson, Michael E; Hevener, Kirk E

    2013-09-12

    A critical analysis of virtual screening results published between 2007 and 2011 was performed. The activity of reported hit compounds from over 400 studies was compared to their hit identification criteria. Hit rates and ligand efficiencies were calculated to assist in these analyses, and the results were compared with factors such as the size of the virtual library and the number of compounds tested. A series of promiscuity, druglike, and ADMET filters were applied to the reported hits to assess the quality of compounds reported, and a careful analysis of a subset of the studies that presented hit optimization was performed. These data allowed us to make several practical recommendations with respect to selection of compounds for experimental testing, definition of hit identification criteria, and general virtual screening hit criteria to allow for realistic hit optimization. A key recommendation is the use of size-targeted ligand efficiency values as hit identification criteria.

  9. Direct oral anticoagulants for treatment of HIT: update of Hamilton experience and literature review.

    Science.gov (United States)

    Warkentin, Theodore E; Pai, Menaka; Linkins, Lori-Ann

    2017-08-31

    Direct oral anticoagulants (DOACs) are attractive options for treatment of heparin-induced thrombocytopenia (HIT). We report our continuing experience in Hamilton, ON, Canada, since January 1, 2015 (when we completed our prospective study of rivaroxaban for HIT), using rivaroxaban for serologically confirmed HIT (4Ts score ≥4 points; positive platelet factor 4 [PF4]/heparin immunoassay, positive serotonin-release assay). We also performed a literature review of HIT treatment using DOACs (rivaroxaban, apixaban, dabigatran, edoxaban). We focused on patients who received DOAC therapy for acute HIT as either primary therapy (group A) or secondary therapy (group B; initial treatment using a non-DOAC/non-heparin anticoagulant with transition to a DOAC during HIT-associated thrombocytopenia). Our primary end point was occurrence of objectively documented thrombosis during DOAC therapy for acute HIT. We found that recovery without new, progressive, or recurrent thrombosis occurred in all 10 Hamilton patients with acute HIT treated with rivaroxaban. Data from the literature review plus these new data identified a thrombosis rate of 1 of 46 patients (2.2%; 95% CI, 0.4%-11.3%) in patients treated with rivaroxaban during acute HIT (group A, n = 25; group B, n = 21); major hemorrhage was seen in 0 of 46 patients. Similar outcomes in smaller numbers of patients were observed with apixaban (n = 12) and dabigatran (n = 11). DOACs offer simplified management of selected patients, as illustrated by a case of persisting (autoimmune) HIT (>2-month platelet recovery with inversely parallel waning of serum-induced heparin-independent serotonin release) with successful outpatient rivaroxaban management of HIT-associated thrombosis. Evidence supporting efficacy and safety of DOACs for acute HIT is increasing, with the most experience reported for rivaroxaban. © 2017 by The American Society of Hematology.

  10. Efficiency Improvement of HIT Solar Cells on p-Type Si Wafers.

    Science.gov (United States)

    Wei, Chun-You; Lin, Chu-Hsuan; Hsiao, Hao-Tse; Yang, Po-Chuan; Wang, Chih-Ming; Pan, Yen-Chih

    2013-11-22

    Single crystal silicon solar cells are still predominant in the market due to the abundance of silicon on earth and their acceptable efficiency. Different solar-cell structures of single crystalline Si have been investigated to boost efficiency; the heterojunction with intrinsic thin layer (HIT) structure is currently the leading technology. The record efficiency values of state-of-the art HIT solar cells have always been based on n-type single-crystalline Si wafers. Improving the efficiency of cells based on p-type single-crystalline Si wafers could provide broader options for the development of HIT solar cells. In this study, we varied the thickness of intrinsic hydrogenated amorphous Si layer to improve the efficiency of HIT solar cells on p-type Si wafers.

  11. Computational Physics' Greatest Hits

    Science.gov (United States)

    Bug, Amy

    2011-03-01

    The digital computer, has worked its way so effectively into our profession that now, roughly 65 years after its invention, it is virtually impossible to find a field of experimental or theoretical physics unaided by computational innovation. It is tough to think of another device about which one can make that claim. In the session ``What is computational physics?'' speakers will distinguish computation within the field of computational physics from this ubiquitous importance across all subfields of physics. This talk will recap the invited session ``Great Advances...Past, Present and Future'' in which five dramatic areas of discovery (five of our ``greatest hits'') are chronicled: The physics of many-boson systems via Path Integral Monte Carlo, the thermodynamic behavior of a huge number of diverse systems via Monte Carlo Methods, the discovery of new pharmaceutical agents via molecular dynamics, predictive simulations of global climate change via detailed, cross-disciplinary earth system models, and an understanding of the formation of the first structures in our universe via galaxy formation simulations. The talk will also identify ``greatest hits'' in our field from the teaching and research perspectives of other members of DCOMP, including its Executive Committee.

  12. COPD: A stepwise or a hit hard approach?

    Directory of Open Access Journals (Sweden)

    A.J. Ferreira

    2016-07-01

    Full Text Available Current guidelines differ slightly on the recommendations for treatment of Chronic Obstructive Pulmonary Disease (COPD patients, and although there are some undisputed recommendations, there is still debate regarding the management of COPD. One of the hindrances to deciding which therapeutic approach to choose is late diagnosis or misdiagnosis of COPD. After a proper diagnosis is achieved and severity assessed, the choice between a stepwise or “hit hard” approach has to be made. For GOLD A patients the stepwise approach is recommended, whilst for B, C and D patients this remains debatable. Moreover, in patients for whom inhaled corticosteroids (ICS are recommended, a step-up or “hit hard” approach with triple therapy will depend on the patient's characteristics and, for patients who are being over-treated with ICS, ICS withdrawal should be performed, in order to optimize therapy and reduce excessive medications.This paper discusses and proposes stepwise, “hit hard”, step-up and ICS withdrawal therapeutic approaches for COPD patients based on their GOLD group. We conclude that all approaches have benefits, and only a careful patient selection will determine which approach is better, and which patients will benefit the most from each approach. Keywords: COPD, Stepwise, Hit hard, Step-up, ICS withdrawal, Bronchodilators, ICS

  13. Double-hit B-cell lymphomas

    NARCIS (Netherlands)

    Aukema, Sietse M.; Siebert, Reiner; Schuuring, Ed; van Imhoff, Gustaaf W.; Kluin-Nelemans, Hanneke C.; Boerma, Evert-Jan; Kluin, Philip M.

    2011-01-01

    In many B-cell lymphomas, chromosomal translocations are biologic and diagnostic hallmarks of disease. An intriguing subset is formed by the so-called double-hit (DH) lymphomas that are defined by a chromosomal breakpoint affecting the MYC/8q24 locus in combination with another recurrent breakpoint,

  14. Are stripes beneficial? Dazzle camouflage influences perceived speed and hit rates.

    Directory of Open Access Journals (Sweden)

    Bettina von Helversen

    Full Text Available In the animal kingdom, camouflage refers to patterns that help potential prey avoid detection. Mostly camouflage is thought of as helping prey blend in with their background. In contrast, disruptive or dazzle patterns protect moving targets and have been suggested as an evolutionary force in shaping the dorsal patterns of animals. Dazzle patterns, such as stripes and zigzags, are thought to reduce the probability with which moving prey will be captured by impairing predators' perception of speed. We investigated how different patterns of stripes (longitudinal-i.e., parallel to movement direction-and vertical-i.e., perpendicular to movement direction affect the probability with which humans can hit moving objects and if differences in hitting probability are caused by a misperception of speed. A first experiment showed that longitudinally striped objects were hit more often than unicolored objects. However, vertically striped objects did not differ from unicolored objects. A second study examining the link between perceived speed and hitting probability showed that longitudinally and vertically striped objects were both perceived as moving faster and were hit more often than unicolored objects. In sum, our results provide evidence that striped patterns disrupt the perception of speed, which in turn influences how often objects are hit. However, the magnitude and the direction of the effects depend on additional factors such as speed and the task setup.

  15. Influence of Running on Pistol Shot Hit Patterns.

    Science.gov (United States)

    Kerkhoff, Wim; Bolck, Annabel; Mattijssen, Erwin J A T

    2016-01-01

    In shooting scene reconstructions, risk assessment of the situation can be important for the legal system. Shooting accuracy and precision, and thus risk assessment, might be correlated with the shooter's physical movement and experience. The hit patterns of inexperienced and experienced shooters, while shooting stationary (10 shots) and in running motion (10 shots) with a semi-automatic pistol, were compared visually (with confidence ellipses) and statistically. The results show a significant difference in precision (circumference of the hit patterns) between stationary shots and shots fired in motion for both inexperienced and experienced shooters. The decrease in precision for all shooters was significantly larger in the y-direction than in the x-direction. The precision of the experienced shooters is overall better than that of the inexperienced shooters. No significant change in accuracy (shift in the hit pattern center) between stationary shots and shots fired in motion can be seen for all shooters. © 2015 American Academy of Forensic Sciences.

  16. The impact of Health Information Technology (I-HIT) Scale: the Australian results.

    Science.gov (United States)

    Cook, Robyn; Foster, Joanne

    2009-01-01

    One of role of the nurse in the clinical setting is that of co-ordinating communication across the healthcare team. On a daily basis nurses interact with the person receiving care, their family members, and multiple care providers thus placing the nurse in the central position with access to a vast array of information on the person. Through this nurses have historically functioned as "information repositories". With the advent of Health Information Technology (HIT) tools there is a potential that HIT could impact interdisciplinary communication, practice efficiency and effectiveness, relationships and workflow in acute care settings [1][3]. In 2005, the HIMSS Nursing Informatics Community developed the I-HIT Scale to measure the impact of HIT on the nursing role and interdisciplinary communication in USA hospitals. In 2007, nursing informatics colleagues from Australia, Finland, Ireland, New Zealand, Scotland and the USA formed a research collaborative to validate the I-HIT in six additional countries. This paper will discuss the background, methodology, results and implications from the Australian I-HIT survey of over 1,100 nurses. The results are currently being analyzed and will be presented at the conference.

  17. Online examiner calibration across specialties.

    Science.gov (United States)

    Sturman, Nancy; Wong, Wai Yee; Turner, Jane; Allan, Chris

    2017-09-26

    Integrating undergraduate medical curricula horizontally across clinical medical specialties may be a more patient-centred and learner-centred approach than rotating students through specialty-specific teaching and assessment, but requires some interspecialty calibration of examiner judgements. Our aim was to evaluate the acceptability and feasibility of an online pilot of interdisciplinary examiner calibration. Fair clinical assessment is important to both medical students and clinical teachers METHODS: Clinical teachers were invited to rate video-recorded student objective structured clinical examination (OSCE) performances and join subsequent online discussions using the university's learning management system. Post-project survey free-text and Likert-scale participant responses were analysed to evaluate the acceptability of the pilot and to identify recommendations for improvement. Although 68 clinicians were recruited to participate, and there were 1599 hits on recordings and discussion threads, only 25 clinical teachers rated at least one student performance, and 18 posted at least one comment. Participants, including rural doctors, appeared to value the opportunity for interdisciplinary rating calibration and discussion. Although the asynchronous online format had advantages, especially for rural doctors, participants reported considerable IT challenges. Our findings suggest that fair clinical assessment is important to both medical students and clinical teachers. Interspecialty discussions about assessment may have the potential to enrich intraspecialty perspectives, enhance interspecialty engagement and collaboration, and improve the quality of clinical teacher assessment. Better alignment of university and hospital systems, a face to face component and other modifications may have enhanced clinician engagement with this project. Findings suggest that specialty assessment cultures and content expertise may not be barriers to pursuing more integrated

  18. Tolosa-Hunt Syndrome in Double-Hit Lymphoma

    Directory of Open Access Journals (Sweden)

    Prakash Peddi

    2015-01-01

    Full Text Available Tolosa-Hunt syndrome (THS is a painful condition characterized by hemicranial pain, retroorbital pain, loss of vision, oculomotor nerve paralysis, and sensory loss in distribution of ophthalmic and maxillary division of trigeminal nerve. Lymphomas rarely involve cavernous sinus and simulate Tolosa-Hunt syndrome. Here we present a first case of double-hit B cell lymphoma (DHL relapsing and masquerading as Tolosa-Hunt syndrome. The neurological findings were explained by a lymphomatous infiltration of the right Gasserian ganglion which preceded systemic relapse. As part of this report, the diagnostic criteria for Tolosa-Hunt syndrome and double-hit lymphoma are reviewed and updated treatment recommendations are presented.

  19. 75 FR 62399 - Office of the National Coordinator for Health Information Technology; HIT Standards Committee...

    Science.gov (United States)

    2010-10-08

    ... Technology; HIT Standards Committee Schedule for the Assessment of HIT Policy Committee Recommendations.... SUMMARY: Section 3003(b)(3) of the American Recovery and Reinvestment Act of 2009 mandates that the HIT Standards Committee develop a schedule for the assessment of policy recommendations developed by the HIT...

  20. HIT-6 and MIDAS as measures of headache disability in a headache referral population.

    Science.gov (United States)

    Sauro, Khara M; Rose, Marianne S; Becker, Werner J; Christie, Suzanne N; Giammarco, Rose; Mackie, Gordon F; Eloff, Arnoldas G; Gawel, Marek J

    2010-03-01

    The objective of this study was to compare the headache impact test (HIT-6) and the migraine disability assessment scale (MIDAS) as clinical measures of headache-related disability. The degree of headache-related disability is an important factor in treatment planning. Many quality of life and headache disability measures exist but it is unclear which of the available disability measures is the most helpful in planning and measuring headache management. We compared HIT-6 and MIDAS scores from 798 patients from the Canadian Headache Outpatient Registry and Database (CHORD). Correlation and regression analyses were used to examine the relationships between the HIT-6 and MIDAS total scores, headache frequency and intensity, and Beck Depression Inventory (BDI-II) scores. A positive correlation was found between HIT-6 and MIDAS scores (r = 0.52). The BDI-II scores correlated equally with the HIT-6 and the MIDAS (r = 0.42). There was a non-monotonic relationship between headache frequency and the MIDAS, and a non-linear monotonic relationship between headache frequency and the HIT-6 (r = 0.24). The correlation was higher between the intensity and the HIT-6 scores (r = 0.46), than MIDAS (r = 0.26) scores. Seventy-nine percent of patients fell into the most severe HIT-6 disability category, compared with the 57% of patients that fell into the most severe MIDAS disability category. Significantly more patients were placed in a more severe category with the HIT-6 than with the MIDAS (McNemar chi-square = 191 on 6 d.f., P MIDAS appear to measure headache-related disability in a similar fashion. However, some important differences may exist. Headache intensity appears to influence HIT-6 score more than the MIDAS, whereas the MIDAS was influenced more by headache frequency. Using the HIT-6 and MIDAS together may give a more accurate assessment of a patient's headache-related disability.

  1. A radar study of emigratory flight and layer formation by insects at dawn over southern Britain.

    Science.gov (United States)

    Reynolds, D R; Smith, A D; Chapman, J W

    2008-02-01

    Radar observations have consistently shown that high-altitude migratory flight in insects generally occurs after mass take-off at dusk or after take-off over a more extended period during the day (in association with the growth of atmospheric convection). In this paper, we focus on a less-studied third category of emigration - the 'dawn take-off' - as recorded by insect-monitoring radars during the summer months in southern England. In particular, we describe occasions when dawn emigrants formed notable layer concentrations centred at altitudes ranging from ca. 240 m to 700 m above ground, very probably due to the insects responding to local temperature maxima in the atmosphere, such as the tops of inversions. After persisting for several hours through the early morning, the layers eventually merged into the insect activity building up later in the morning (from 06.00-08.00 h onwards) in conjunction with the development of daytime convection. The species forming the dawn layers have not been positively identified, but their masses lay predominantly in the 16-32 mg range, and they evidently formed a fauna quite distinct from that in flight during the previous night. The displacement and common orientation (mutual alignment) characteristics of the migrants are described.

  2. The location of the open-closed magnetic field line boundary in the dawn sector auroral ionosphere

    Directory of Open Access Journals (Sweden)

    J. A. Wild

    2004-11-01

    Full Text Available As a measure of the degree of coupling between the solar wind-magnetosphere-ionosphere systems, the rate at which the size of the polar cap (the region corresponding to ionospheric termini of open magnetic flux tubes varies is of prime importance. However, a reliable technique by which the extent of the polar cap might be routinely monitored has yet to be developed. Current techniques provide particularly ambiguous indications of the polar cap boundary in the dawn sector. We present a case study of space- and ground-based observations of the dawn-sector auroral zone and attempt to determine the location of the polar cap boundary using multi-wavelength observations of the ultraviolet aurora (made by the IMAGE FUV imager, precipitating particle measurements (recorded by the FAST, DMSP, and Cluster 1 and 3 satellites, and SuperDARN HF radar observations of the ionospheric Doppler spectral width boundary. We conclude that in the dawn sector, during the interval presented, neither the poleward edge of the wideband auroral UV emission (140-180nm nor the Doppler spectral width boundary were trustworthy indicators of the polar cap boundary location, while narrow band UV emissions in the range 130-140nm appear to be much more reliable.

  3. Does ′heparin-induced thrombocytopenia′ hit our minds?

    Directory of Open Access Journals (Sweden)

    Arun R Thangavel

    2016-01-01

    Full Text Available Unfractionated heparin is a widely used drug to prevent deep vein thrombosis and pulmonary emboli in patients at risk. With the advent of newer anticoagulants having lesser side effects, its use has diminished but not out of service. Here, we report a case of deep venous thrombosis, in a patient on prophylactic dose of heparin, which was later found to be a manifestation of heparin-induced thrombocytopenia (HIT. Thrombosis in the presence of heparin prophylaxis should be considered as HIT rather than a failure of anticoagulation.

  4. Nedley Depression Hit Hypothesis: Identifying Depression and Its Causes.

    Science.gov (United States)

    Nedley, Neil; Ramirez, Francisco E

    2016-11-01

    Depression is often diagnosed using the Diagnostic and Statistical Manual of Mental Disorders Fifth Edition (DSM-5) criteria. We propose how certain lifestyle choices and non-modifiable factors can predict the development of depression. We identified 10 cause categories (hits or "blows" to the brain) and theorize that four or more active hits could trigger a depression episode. Methods. A sample of 4271 participants from our community-based program (70% female; ages 17-94 years) was assessed at baseline and at the eighth week of the program using a custom test. Ten cause categories were examined as predictors of depression are (1) Genetic, (2)Developmental, (3)Lifestyle, (4)Circadian Rhythm, (5)Addiction, (6)Nutrition, (7)Toxic, (8)Social/Complicated Grief, (9)Medical Condition, and (10)Frontal Lobe. Results. The relationship between the DSM-5 score and a person having four hits categories in the first program week showed a sensitivity of 89.98 % (95% CI: 89.20 % - 90.73%), specificity 48.84% (CI 45.94-51.75) and Matthew Correlation Coefficient (MCC) .41 . For the eight-week test, the results showed a sensitivity 83.6% (CI 81.9-85.5), specificity 53.7% (CI 51.7-55.6) and MCC .38. Overall, the hits that improved the most from baseline after the eighth week were: Nutrition (47%), Frontal lobe (36%), Addiction (24%), Circadian rhythm (24%), Lifestyle (20%), Social (12%) and Medical (10%). Conclusions. The Nedley four-hit hypothesis seems to predict a depressive episode and correlates well with the DSM-5 criteria with good sensitivity and MCC but less specificity. Identifying these factors and applying lifestyle therapies could play an important role in the treatment of depressed individuals.

  5. Measurements of the global 21-cm signal from the Cosmic Dawn

    Science.gov (United States)

    Bernardi, Gianni

    2018-05-01

    The sky-averaged (global) 21-cm signal is a very promising probe of the Cosmic Dawn, when the first luminous sources were formed and started to shine in a substantially neutral intergalactic medium. I here report on the status and early result of the Large-Aperture Experiment to Detect the Dark Age that focuses on observations of the global 21-cm signal in the 16 <~ z <~ 30 range.

  6. A simple model describing the nonlinear dynamics of the dusk/dawn asymmetry in the high-latitude thermospheric flow

    Science.gov (United States)

    Gundlach, J. P.; Larsen, M. F.; Mikkelsen, I. S.

    1988-01-01

    A simple nonlinear, axisymmetric, shallow-water numerical model has been used to study the asymmetry in the neutral flow between the dusk and dawn sides of the auroral oval. The results indicate that the Coriolis force and the curvature terms are nearly in balance on the evening side and require only a small pressure gradient to effect adjustment. The result is smaller neutral velocities near dawn and larger velocities near dusk than would be the case for a linearized treatment. A consequence is that more gravity wave energy is produced on the morning side than on the evening side.

  7. MD#1182: Calibration of diamond particle detectors in IP6

    CERN Document Server

    Valette, Matthieu; Lindstrom, Bjorn Hans Filip; Wiesner, Christoph

    2017-01-01

    In case of an asynchronous beam dump with a fully filled LHC machine it is expected that all standard ionisation chamber Beam Loss Monitors (IC BLM) around the LHC dumping region in IP6 will be saturated. Diamond Beam Loss Monitors (dBLM) were therefore installed next to the movable dump protection absorber (TCDQ) downstream of the extraction kickers. These detectors allow resolving losses at a nanosecond timescale and with an dynamic range of several orders of magnitude; thus, allowing to know the number of nominal bunches impacting the TCDQ. After a first series of calibrations using asynchronous beam dump tests, an experiment was conducted during MD#1182 to demonstrate the possibility of resolving a nominal bunch hitting the TCDQ. The impact parameter of the bunches on the TCDQ was first scanned using probe bunches with lower intensity then tests were done with nominal bunches (1.1e11 p/bunch) at injection energy. High energy calibration of the losses was also attempted unsuccessfully. Due to different beh...

  8. 77 FR 57567 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-09-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  9. 77 FR 50690 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-08-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  10. 77 FR 15760 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  11. 76 FR 39108 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-07-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS ACTION: Notice of... the public. Name of Committee: HIT Policy Committee. General Function of the Committee: to provide...

  12. 77 FR 37407 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-06-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  13. 76 FR 22397 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  14. 77 FR 22787 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-04-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  15. 77 FR 27459 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-05-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: to provide recommendations to...

  16. 76 FR 28783 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-05-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  17. 76 FR 79684 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-12-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  18. 77 FR 73660 - HIT Policy Committee Advisory Meetings; Notice of Meetings

    Science.gov (United States)

    2012-12-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meetings; Notice of Meetings AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  19. 77 FR 28881 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-05-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: to provide recommendations to...

  20. 76 FR 46298 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-08-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  1. 77 FR 65691 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-10-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  2. 76 FR 70455 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-11-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: to provide recommendations to...

  3. 77 FR 2727 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-01-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  4. 76 FR 14975 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: to provide recommendations to...

  5. 76 FR 50734 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  6. 76 FR 55912 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2011-09-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... the public. Name of Committee: HIT Policy Committee. General Function of the Committee: To provide...

  7. 77 FR 41788 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2012-07-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of... of Committee: HIT Policy Committee. General Function of the Committee: To provide recommendations to...

  8. SHIELD-HIT12A - a Monte Carlo particle transport program for ion therapy research

    DEFF Research Database (Denmark)

    Bassler, Niels; Hansen, David Christoffer; Lühr, Armin

    2014-01-01

    . We experienced that new users quickly learn to use SHIELD-HIT12A and setup new geometries. Contrary to previous versions of SHIELD-HIT, the 12A distribution comes along with easy-to-use example files and an English manual. A new implementation of Vavilov straggling resulted in a massive reduction......Abstract. Purpose: The Monte Carlo (MC) code SHIELD-HIT simulates the transport of ions through matter. Since SHIELD-HIT08 we added numerous features that improves speed, usability and underlying physics and thereby the user experience. The “-A” fork of SHIELD-HIT also aims to attach SHIELD....... It supports native formats compatible with the heavy ion treatment planning system TRiP. Stopping power files follow ICRU standard and are generated using the libdEdx library, which allows the user to choose from a multitude of stopping power tables. Results: SHIELD-HIT12A runs on Linux and Windows platforms...

  9. Effects of artificial dawn on sleep inertia, skin temperature, and the awakening cortisol response

    NARCIS (Netherlands)

    van de Werken, Maan; Gimenez, Marina C.; de Vries, Bonnie; Beersma, Domien G. M.; van Someren, Eus J. W.; Gordijn, Marijke C. M.

    P>The effect of artificial dawn during the last 30 min of sleep on subsequent dissipation of sleep inertia was investigated, including possible involvement of cortisol and thermoregulatory processes. Sixteen healthy subjects who reported difficulty with waking up participated in random order in a

  10. 75 FR 21629 - HIT Policy Committee Advisory Meeting; Notice of Meeting

    Science.gov (United States)

    2010-04-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Office of the National Coordinator for Health Information Technology HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Policy Committee...

  11. Vesta and Ceres as Seen by Dawn

    Science.gov (United States)

    Russell, C. T.; Nathues, A.; De Sanctis, M. C.; Prettyman, T. H.; Konopliv, A. S.; Park, R. S.; Jaumann, R.; McSween, H. Y., Jr.; Raymond, C. A.; Pieters, C. M.; McCord, T. B.; Marchi, S.; Schenk, P.; Buczkowski, D.

    2015-12-01

    Ceres and Vesta are the most massive bodies in the main asteroid belt. They have witnessed 4.6 Ga of solar system history. Dawn's objective is to interview these two witnesses. These bodies are relatively simple protoplanets, with a modest amount of thermal evolution and geochemical alteration. They are our best archetypes of the early building blocks of the terrestrial planets. In particular siderophile elements in the Earth's core were probably first segregated in Vesta-like bodies, and its water was likely first condensed in Ceres-like bodies. Vesta has provided copious meteorites for geochemical analysis. This knowledge was used to infer the constitution of the parent body. Dawn verified that Vesta was consistent with being that body, confirming the geochemical inferences from these samples on the formation and evolution of the solar system. Ceres has not revealed itself with a meteoritic record nor an asteroid family. While the surface is scarred with craters, it is probable that the ejecta from the crater-forming events created little competent material from the icy crust and any such ejected material that reached Earth might have disintegrated upon entry into the Earth's atmosphere. Ceres' surface differs greatly from Vesta's. Plastic or fluidized mass wasting is apparent as are many irregularly shaped craters, including many polygonal crater forms. There are many central-pit craters possibly caused by volatilization of the crust in the center of the impact. There are many central-peak craters but are these due to rebound or pingo-like formation processes? Bright spots, possibly salt deposits, dot the landscape, evidence of fluvial processes beneath the crust. Observations of the largest region of bright spots may suggest sublimation from the surface of the bright area, consistent with Herschel water vapor observations. Ceres is not only the most massive body in the asteroid belt but also possibly the most active occupant of the main belt.

  12. Multi-hit time-to-amplitude CAMAC module (MTAC)

    International Nuclear Information System (INIS)

    Kang, H.

    1980-10-01

    A Multi-Hit Time-to-Amplitude Module (MTAC) for the SLAC Mark III drift chamber system has been designed to measure drift time by converting time-proportional chamber signals into analog levels, and converting the analog data by slow readout via a semi-autonomous controller in a CAMAC crate. The single width CAMAC module has 16 wire channels, each with a 4-hit capacity. An externally generated common start initiates an internal precision ramp voltage which is then sampled using a novel shift register gating scheme and CMOS sampling switches. The detailed design and performance specifications are described

  13. Ceres Photometry and Albedo from Dawn Framing Camera Images

    Science.gov (United States)

    Schröder, S. E.; Mottola, S.; Keller, H. U.; Li, J.-Y.; Matz, K.-D.; Otto, K.; Roatsch, T.; Stephan, K.; Raymond, C. A.; Russell, C. T.

    2015-10-01

    The Dawn spacecraft is in orbit around dwarf planet Ceres. The onboard Framing Camera (FC) [1] is mapping the surface through a clear filter and 7 narrow-band filters at various observational geometries. Generally, Ceres' appearance in these images is affected by shadows and shading, effects which become stronger for larger solar phase angles, obscuring the intrinsic reflective properties of the surface. By means of photometric modeling we attempt to remove these effects and reconstruct the surface albedo over the full visible wavelength range. Knowledge of the albedo distribution will contribute to our understanding of the physical nature and composition of the surface.

  14. Improvements to the ion Doppler spectrometer diagnostic on the HIT-SI experiments

    Science.gov (United States)

    Hossack, Aaron; Chandra, Rian; Everson, Chris; Jarboe, Tom

    2018-03-01

    An ion Doppler spectrometer diagnostic system measuring impurity ion temperature and velocity on the HIT-SI and HIT-SI3 spheromak devices has been improved with higher spatiotemporal resolution and lower error than previously described devices. Hardware and software improvements to the established technique have resulted in a record of 6.9 μs temporal and ≤2.8 cm spatial resolution in the midplane of each device. These allow Ciii and Oii flow, displacement, and temperature profiles to be observed simultaneously. With 72 fused-silica fiber channels in two independent bundles, and an f/8.5 Czerny-Turner spectrometer coupled to a video camera, frame rates of up to ten times the imposed magnetic perturbation frequency of 14.5 kHz were achieved in HIT-SI, viewing the upper half of the midplane. In HIT-SI3, frame rates of up to eight times the perturbation frequency were achieved viewing both halves of the midplane. Biorthogonal decomposition is used as a novel filtering tool, reducing uncertainty in ion temperature from ≲13 to ≲5 eV (with an instrument temperature of 8-16 eV) and uncertainty in velocity from ≲2 to ≲1 km/s. Doppler shift and broadening are calculated via the Levenberg-Marquardt algorithm, after which the errors in velocity and temperature are uniquely specified. Axisymmetric temperature profiles on HIT-SI3 for Ciii peaked near the inboard current separatrix at ≈40 eV are observed. Axisymmetric plasma displacement profiles have been measured on HIT-SI3, peaking at ≈6 cm at the outboard separatrix. Both profiles agree with the upper half of the midplane observable by HIT-SI. With its complete midplane view, HIT-SI3 has unambiguously extracted axisymmetric, toroidal current dependent rotation of up to 3 km/s. Analysis of the temporal phase of the displacement uncovers a coherent structure, locked to the applied perturbation. Previously described diagnostic systems could not achieve such results.

  15. NMR characterization of weak interactions between RhoGDI2 and fragment screening hits.

    Science.gov (United States)

    Liu, Jiuyang; Gao, Jia; Li, Fudong; Ma, Rongsheng; Wei, Qingtao; Wang, Aidong; Wu, Jihui; Ruan, Ke

    2017-01-01

    The delineation of intrinsically weak interactions between novel targets and fragment screening hits has long limited the pace of hit-to-lead evolution. Rho guanine-nucleotide dissociation inhibitor 2 (RhoGDI2) is a novel target that lacks any chemical probes for the treatment of tumor metastasis. Protein-observed and ligand-observed NMR spectroscopy was used to characterize the weak interactions between RhoGDI2 and fragment screening hits. We identified three hits of RhoGDI2 using streamlined NMR fragment-based screening. The binding site residues were assigned using non-uniformly sampled C α - and H α -based three dimensional NMR spectra. The molecular docking to the proposed geranylgeranyl binding pocket of RhoGDI2 was guided by NMR restraints of chemical shift perturbations and ligand-observed transferred paramagnetic relaxation enhancement. We further validated the weak RhoGDI2-hit interactions using mutagenesis and structure-affinity analysis. Weak interactions between RhoGDI2 and fragment screening hits were delineated using an integrated NMR approach. Binders to RhoGDI2 as a potential anti-cancer target have been first reported, and their weak interactions were depicted using NMR spectroscopy. Our work highlights the powerfulness and the versatility of the integrative NMR techniques to provide valuable structural insight into the intrinsically weak interactions between RhoGDI2 and the fragment screening hits, which could hardly be conceived using other biochemical techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Development and psychometric evaluation of the Impact of Health Information Technology (I-HIT) scale.

    Science.gov (United States)

    Dykes, Patricia C; Hurley, Ann; Cashen, Margaret; Bakken, Suzanne; Duffy, Mary E

    2007-01-01

    The use of health information technology (HIT) for the support of communication processes and data and information access in acute care settings is a relatively new phenomenon. A means of evaluating the impact of HIT in hospital settings is needed. The purpose of this research was to design and psychometrically evaluate the Impact of Health Information Technology scale (I-HIT). I-HIT was designed to measure the perception of nurses regarding the ways in which HIT influences interdisciplinary communication and workflow patterns and nurses' satisfaction with HIT applications and tools. Content for a 43-item tool was derived from the literature, and supported theoretically by the Coiera model and by nurse informaticists. Internal consistency reliability analysis using Cronbach's alpha was conducted on the 43-item scale to initiate the item reduction process. Items with an item total correlation of less than 0.35 were removed, leaving a total of 29 items. Item analysis, exploratory principal component analysis and internal consistency reliability using Cronbach's alpha were used to confirm the 29-item scale. Principal components analysis with Varimax rotation produced a four-factor solution that explained 58.5% of total variance (general advantages, information tools to support information needs, information tools to support communication needs, and workflow implications). Internal consistency of the total scale was 0.95 and ranged from 0.80-0.89 for four subscales. I-HIT demonstrated psychometric adequacy and is recommended to measure the impact of HIT on nursing practice in acute care settings.

  17. Plasma exchange to remove HIT antibodies: dissociation between enzyme-immunoassay and platelet activation test reactivities.

    Science.gov (United States)

    Warkentin, Theodore E; Sheppard, Jo-Ann I; Chu, F Victor; Kapoor, Anil; Crowther, Mark A; Gangji, Azim

    2015-01-01

    Repeated therapeutic plasma exchange (TPE) has been advocated to remove heparin-induced thrombocytopenia (HIT) IgG antibodies before cardiac/vascular surgery in patients who have serologically-confirmed acute or subacute HIT; for this situation, a negative platelet activation assay (eg, platelet serotonin-release assay [SRA]) has been recommended as the target serological end point to permit safe surgery. We compared reactivities in the SRA and an anti-PF4/heparin IgG-specific enzyme immunoassay (EIA), testing serial serum samples in a patient with recent (subacute) HIT who underwent serial TPE precardiac surgery, as well as for 15 other serially-diluted HIT sera. We observed that post-TPE/diluted HIT sera-when first testing SRA-negative-continue to test strongly positive by EIA-IgG. This dissociation between the platelet activation assay and a PF4-dependent immunoassay for HIT antibodies indicates that patients with subacute HIT undergoing repeated TPE before heparin reexposure should be tested by serial platelet activation assays even when their EIAs remain strongly positive. © 2015 by The American Society of Hematology.

  18. Progress on FIR interferometry and Thomson Scattering measurements on HIT-SI3

    Science.gov (United States)

    Everson, Christopher; Jarboe, Thomas; Morgan, Kyle

    2017-10-01

    Spatially resolved measurements of the electron temperature (Te) and density (ne) will be fundamental in assessing the degree to which HIT-SI3 demonstrates closed magnetic flux and energy confinement. Further, electron temperature measurements have not yet been made on an inductively-driven spheromak. Far infrared (FIR) interferometer and Thomson Scattering (TS) systems have been installed on the HIT-SI3 spheromak. The TS system currently implemented on HIT-SI3 was originally designed for other magnetic confinement experiments, and progress continues toward modifying and optimizing for HIT-SI3 plasmas. Initial results suggest that the electron temperature is of order 10 eV. Plans to modify the TS system to provide more sensitivity and accuracy at low temperatures are presented. The line-integrated ne is measured on one chord by the FIR interferometer, with densities near 5x1019 m-3. Four cylindrical volumes have been added to the HIT-SI3 apparatus to enhance passive pumping. It is hoped that this will allow for more control of the density during the 2 ms discharges. Density measurements from before and after the installation of the passive pumping volumes are presented for comparison.

  19. Calibration factor or calibration coefficient?

    International Nuclear Information System (INIS)

    Meghzifene, A.; Shortt, K.R.

    2002-01-01

    Full text: The IAEA/WHO network of SSDLs was set up in order to establish links between SSDL members and the international measurement system. At the end of 2001, there were 73 network members in 63 Member States. The SSDL network members provide calibration services to end-users at the national or regional level. The results of the calibrations are summarized in a document called calibration report or calibration certificate. The IAEA has been using the term calibration certificate and will continue using the same terminology. The most important information in a calibration certificate is a list of calibration factors and their related uncertainties that apply to the calibrated instrument for the well-defined irradiation and ambient conditions. The IAEA has recently decided to change the term calibration factor to calibration coefficient, to be fully in line with ISO [ISO 31-0], which recommends the use of the term coefficient when it links two quantities A and B (equation 1) that have different dimensions. The term factor should only be used for k when it is used to link the terms A and B that have the same dimensions A=k.B. However, in a typical calibration, an ion chamber is calibrated in terms of a physical quantity such as air kerma, dose to water, ambient dose equivalent, etc. If the chamber is calibrated together with its electrometer, then the calibration refers to the physical quantity to be measured per electrometer unit reading. In this case, the terms referred have different dimensions. The adoption by the Agency of the term coefficient to express the results of calibrations is consistent with the 'International vocabulary of basic and general terms in metrology' prepared jointly by the BIPM, IEC, ISO, OIML and other organizations. The BIPM has changed from factor to coefficient. The authors believe that this is more than just a matter of semantics and recommend that the SSDL network members adopt this change in terminology. (author)

  20. 76 FR 4352 - Office of the National Coordinator for Health Information Technology; HIT Policy Committee's...

    Science.gov (United States)

    2011-01-25

    ... Technology; HIT Policy Committee's Workgroup Meetings; Notice of Meetings AGENCY: Office of the National... only. Name of Committees: HIT Policy Committee's Workgroups: Meaningful Use, Privacy & Security Tiger..., implementation specifications, and certification criteria are needed. Date and Time: The HIT Policy Committee...

  1. The T10 beam produces a few hits per event. In ALICE the SSD will have to cope with many hits per strip. In the three centimeters of aluminium the beam will produce many secondary particles. This increases the chance of multiple hits per strip, although not to the level in ALICE.

    CERN Multimedia

    Nooren, G.

    2004-01-01

    The T10 beam produces a few hits per event. In ALICE the SSD will have to cope with many hits per strip. In the three centimeters of aluminium the beam will produce many secondary particles. This increases the chance of multiple hits per strip, although not to the level in ALICE.

  2. Platelet count recovery and seroreversion in immune HIT despite continuation of heparin: further observations and literature review.

    Science.gov (United States)

    Shih, Andrew W; Sheppard, Jo-Ann I; Warkentin, Theodore E

    2017-10-05

    One of the standard distinctions between type 1 (non-immune) and type 2 (immune-mediated) heparin-induced thrombocytopenia (HIT) is the transience of thrombocytopenia: type 1 HIT is viewed as early-onset and transient thrombocytopenia, with platelet count recovery despite continuing heparin administration. In contrast, type 2 HIT is viewed as later-onset (i. e., 5 days or later) thrombocytopenia in which it is generally believed that platelet count recovery will not occur unless heparin is discontinued. However, older reports of type 2 HIT sometimes did include the unexpected observation that platelet counts could recover despite continued heparin administration, although without information provided regarding changes in HIT antibody levels in association with platelet count recovery. In recent years, some reports of type 2 HIT have confirmed the observation that platelet count recovery can occur despite continuing heparin administration, with serological evidence of waning levels of HIT antibodies ("seroreversion"). We now report two additional patient cases of type 2 HIT with platelet count recovery despite ongoing therapeutic-dose (1 case) or prophylactic-dose (1 case) heparin administration, in which we demonstrate concomitant waning of HIT antibody levels. We further review the literature describing this phenomenon of HIT antibody seroreversion and platelet count recovery despite continuing heparin administration. Our observations add to the concept that HIT represents a remarkably transient immune response, including sometimes even when heparin is continued.

  3. Health Information Technologies-Academic and Commercial Evaluation (HIT-ACE) methodology: description and application to clinical feedback systems.

    Science.gov (United States)

    Lyon, Aaron R; Lewis, Cara C; Melvin, Abigail; Boyd, Meredith; Nicodimos, Semret; Liu, Freda F; Jungbluth, Nathaniel

    2016-09-22

    Health information technologies (HIT) have become nearly ubiquitous in the contemporary healthcare landscape, but information about HIT development, functionality, and implementation readiness is frequently siloed. Theory-driven methods of compiling, evaluating, and integrating information from the academic and commercial sectors are necessary to guide stakeholder decision-making surrounding HIT adoption and to develop pragmatic HIT research agendas. This article presents the Health Information Technologies-Academic and Commercial Evaluation (HIT-ACE) methodology, a structured, theory-driven method for compiling and evaluating information from multiple sectors. As an example demonstration of the methodology, we apply HIT-ACE to mental and behavioral health measurement feedback systems (MFS). MFS are a specific class of HIT that support the implementation of routine outcome monitoring, an evidence-based practice. HIT-ACE is guided by theories and frameworks related to user-centered design and implementation science. The methodology involves four phases: (1) coding academic and commercial materials, (2) developer/purveyor interviews, (3) linking putative implementation mechanisms to hit capabilities, and (4) experimental testing of capabilities and mechanisms. In the current demonstration, phase 1 included a systematic process to identify MFS in mental and behavioral health using academic literature and commercial websites. Using user-centered design, implementation science, and feedback frameworks, the HIT-ACE coding system was developed, piloted, and used to review each identified system for the presence of 38 capabilities and 18 additional characteristics via a consensus coding process. Bibliometic data were also collected to examine the representation of the systems in the scientific literature. As an example, results are presented for the application of HIT-ACE phase 1 to MFS wherein 49 separate MFS were identified, reflecting a diverse array of characteristics

  4. 75 FR 3906 - Office of the National Coordinator for Health Information Technology; HIT Policy Committee's...

    Science.gov (United States)

    2010-01-25

    ... Technology; HIT Policy Committee's Workgroup Meetings; Notice of Meetings AGENCY: Office of the National... only. Name of Committees: HIT Policy Committee's Workgroups: Meaningful Use, Privacy & Security Policy... specifications, and certification criteria are needed. Date and Time: The HIT Policy Committee Workgroups will...

  5. A new DAWN: Improving the psychosocial management of diabetes

    Directory of Open Access Journals (Sweden)

    Richard I. G. Holt

    2013-01-01

    Full Text Available Aims: The second Diabetes Attitudes, Wishes and Needs (DAWN-2 study assessed psychosocial issues and health-care provision of people with diabetes, their family members and health-care professionals. Materials and Methods: Participants completed an online, telephone or in-person survey designed to assess health-related quality-of-life, self-management, attitudes/beliefs, social support and priorities for improving diabetes care as well as health-care provision and the impact of diabetes on family life. Results: A total of 8596 adults with diabetes, 2057 family members of people with diabetes and 4785 health-care professionals across 17 countries completed the survey. There were significant between country differences, but no one country′s outcomes were consistently better or worse than others. A high proportion of people with diabetes reported likely depression (13.8% and poor quality-of-life (12.2%. Diabetes had a negative impact on many aspects of life, including relationships with family/friends and physical health. A third of family members did not know how to help the person with diabetes, but wanted to be more involved in their care. Many health-care professionals indicated that major improvements were needed across a range of areas including health-care organization, resources for diabetes prevention, earlier diagnosis and treatment and psychological support. Conclusions: DAWN-2 is a multinational, multidisciplinary systematic study that compared unmet needs of people with diabetes and those who care for them in 17 countries across four continents. Its findings should facilitate innovative efforts to improve self-management and psychosocial support in diabetes, with the aim of reducing the burden of disease. The implications for India are discussed.

  6. PHASE ANGLE EFFECTS ON 3 μm ABSORPTION BAND ON CERES: IMPLICATIONS FOR DAWN MISSION

    Energy Technology Data Exchange (ETDEWEB)

    Takir, D.; Reddy, V.; Sanchez, J. A.; Corre, L. Le [Planetary Science Institute, 1700 E Fort Lowell Road, Suite 106, Tucson, AZ 85719 (United States); Hardersen, P. S. [Department of Space Studies, University of North Dakota, Grand Forks, ND 58202 (United States); Nathues, A., E-mail: dtakir@psi.edu [Max-Planck-Institute for Solar System Research, Justus-von-Liebig-Weg 3, D-37077 Göttingen (Germany)

    2015-05-01

    Phase angle-induced spectral effects are important to characterize since they affect spectral band parameters such as band depth and band center, and therefore skew mineralogical interpretations of planetary bodies via reflectance spectroscopy. Dwarf planet (1) Ceres is the next target of NASA’s Dawn mission, which is expected to arrive in 2015 March. The visible and near-infrared mapping spectrometer (VIR) on board Dawn has the spatial and spectral range to characterize the surface between 0.25–5.0 μm. Ceres has an absorption feature at 3.0 μm due to hydroxyl- and/or water-bearing minerals. We analyzed phase angle-induced spectral effects on the 3 μm absorption band on Ceres using spectra measured with the long-wavelength cross-dispersed (LXD: 1.9–4.2 μm) mode of the SpeX spectrograph/imager at the NASA Infrared Telescope Facility. Ceres LXD spectra were measured at different phase angles ranging from 0.°7 to 22°. We found that the band center slightly increases from 3.06 μm at lower phase angles (0.°7 and 6°) to 3.07 μm at higher phase angles (11° and 22°), the band depth decreases by ∼20% from lower phase angles to higher phase angles, and the band area decreases by ∼25% from lower phase angles to higher phase angles. Our results will have implications for constraining the abundance of OH on the surface of Ceres from VIR spectral data, which will be acquired by Dawn starting spring 2015.

  7. PHASE ANGLE EFFECTS ON 3 μm ABSORPTION BAND ON CERES: IMPLICATIONS FOR DAWN MISSION

    International Nuclear Information System (INIS)

    Takir, D.; Reddy, V.; Sanchez, J. A.; Corre, L. Le; Hardersen, P. S.; Nathues, A.

    2015-01-01

    Phase angle-induced spectral effects are important to characterize since they affect spectral band parameters such as band depth and band center, and therefore skew mineralogical interpretations of planetary bodies via reflectance spectroscopy. Dwarf planet (1) Ceres is the next target of NASA’s Dawn mission, which is expected to arrive in 2015 March. The visible and near-infrared mapping spectrometer (VIR) on board Dawn has the spatial and spectral range to characterize the surface between 0.25–5.0 μm. Ceres has an absorption feature at 3.0 μm due to hydroxyl- and/or water-bearing minerals. We analyzed phase angle-induced spectral effects on the 3 μm absorption band on Ceres using spectra measured with the long-wavelength cross-dispersed (LXD: 1.9–4.2 μm) mode of the SpeX spectrograph/imager at the NASA Infrared Telescope Facility. Ceres LXD spectra were measured at different phase angles ranging from 0.°7 to 22°. We found that the band center slightly increases from 3.06 μm at lower phase angles (0.°7 and 6°) to 3.07 μm at higher phase angles (11° and 22°), the band depth decreases by ∼20% from lower phase angles to higher phase angles, and the band area decreases by ∼25% from lower phase angles to higher phase angles. Our results will have implications for constraining the abundance of OH on the surface of Ceres from VIR spectral data, which will be acquired by Dawn starting spring 2015

  8. Insights from the correlation of the preliminary Geologic and Mineralogic maps of Vesta from the Dawn mission data

    Science.gov (United States)

    Frigeri, A.; De Sanctis, M. C.; Ammannito, E.; Yingst, R. A.; Mest, S.; Garry, B.; Magni, G.; Palomba, E.; Petro, N.; Tosi, F.; Williams, D.; Zambon, F.; Jaumann, R.; Pieters, C. M.; Raymond, C. A.; Russell, C. T.

    2012-04-01

    The Dawn mission to Vesta has greatly improved the quality and resolution of data available to explore the asteroid. Prior to the Dawn mission the best data available was the one from Hubble Space Telescope with a maximum resolution of 50 km per pixel. The survey phase of the mission has pushed spatial resolution up to about 100 meters per pixel by the Framing Camera on-board Dawn, and 700 meters per pixel for the VIR spectrometer, spanning the spectral range from the visible to infrared at 0.25-1 μm and 1-5 μm. The frames of the FC and VIR have been processed and mosaicked. A preliminary Geologic map has been produced by mapping units and structures over the FC mosaic and the DTM derived from stereo processing of visible imagery. We will present some examples of correlation between the preliminary geologic and VIR-derived mineralogic maps. The Dawn mission team is using Geographic Information System tools for locating frames and for data exchange among the team. The use of GIS tools and data formats significantly improves our ability to create and interpret geologic maps, and also improves the interoperability of high level data products among the instruments' team. VIR data have been synthesized into a series of spectral indicators that give indications on the mineralogical composition and the physical state of the surface. We ingested in GIS the the preliminary geologic map as units and structures and we projected the mosaics of spectral indicators in a common coordinate reference system. The first spectral indicators we started to look at were the Band Depth computed on pyroxene Band II and the Band Center also computed on Band II. The comparison of the preliminary geologic map and the mosaics of spectral indicators extracted from VIR data show promising aspects on both the geologic and mineralogic aspects. Geologic units are made up of bodies of rock that are interpreted to have been formed by a particular process or set of related processes over a discrete

  9. Calibrating Accelerometers Using an Electromagnetic Launcher

    Energy Technology Data Exchange (ETDEWEB)

    Erik Timpson

    2012-05-13

    A Pulse Forming Network (PFN), Helical Electromagnetic Launcher (HEML), Command Module (CM), and Calibration Table (CT) were built and evaluated for the combined ability to calibrate an accelerometer. The PFN has a maximum stored energy of 19.25 kJ bank and is fired by a silicon controlled rectifier (SCR), with appropriate safety precautions. The HEML is constructed out of G-10 fiberglass and is designed to accelerate 600 grams to 10 meters per second. The CM is microcontroller based running Arduino Software. The CM has a keypad input and 7 segment outputs of the bank voltage and desired voltage. After entering a desired bank voltage, the CM controls the charge of the PFN. When the two voltages are equal it allows the fire button to send a pulse to the SCR to fire the PFN and in turn, the HEML. The HEML projectile's tip hits a target that is held by the CT. The CT consists of a table to hold the PFN and HEML, a vacuum chuck, air bearing, velocity meter and catch pot. The Target is held with the vacuum chuck awaiting impact. After impact, the air bearing allows the target to fall freely for the velocity meter to get an accurate reading. A known acceleration is determined from the known change in velocity of the target. Thus, if an accelerometer was attached to the target, the measured value can be compared to the known value.

  10. 75 FR 65636 - Office of the National Coordinator for Health Information Technology; HIT Standards Committee...

    Science.gov (United States)

    2010-10-26

    ... Technology; HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards... Strategic Plan, and in accordance with policies developed by the HIT Policy Committee. Date and Time: The...

  11. 75 FR 57027 - Office of the National Coordinator for Health Information Technology; HIT Standards Committee...

    Science.gov (United States)

    2010-09-17

    ... Technology; HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards... Strategic Plan, and in accordance with policies developed by the HIT Policy Committee. Date and Time: The...

  12. 75 FR 42090 - Office of the National Coordinator for Health Information Technology; HIT Standards Committee...

    Science.gov (United States)

    2010-07-20

    ... Technology; HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards... Strategic Plan, and in accordance with policies developed by the HIT Policy Committee. Date and Time: The...

  13. Laboratory tests for identification or exclusion of heparin induced thrombocytopenia: HIT or miss?

    Science.gov (United States)

    Favaloro, Emmanuel J

    2018-02-01

    Heparin induced thrombocytopenia (HIT) is a potentially fatal condition that arises subsequent to formation of antibodies against complexes containing heparin, usually platelet-factor 4-heparin ("anti-PF4-heparin"). Assessment for HIT involves both clinical evaluation and, if indicated, laboratory testing for confirmation or exclusion, typically using an initial immunological assay ("screening"), and only if positive, a secondary functional assay for confirmation. Many different immunological and functional assays have been developed. The most common contemporary immunological assays comprise enzyme-linked immunosorbent assay [ELISA], chemiluminescence, lateral flow, and particle gel techniques. The most common functional assays measure platelet aggregation or platelet activation events (e.g., serotonin release assay; heparin-induced platelet activation (HIPA); flow cytometry). All assays have some sensitivity and specificity to HIT antibodies, but differ in terms of relative sensitivity and specificity for pathological HIT, as well as false negative and false positive error rate. This brief article overviews the different available laboratory methods, as well as providing a suggested approach to diagnosis or exclusion of HIT. © 2017 Wiley Periodicals, Inc.

  14. MIDAS and HIT-6 French translation: reliability and correlation between tests.

    Science.gov (United States)

    Magnoux, E; Freeman, M A; Zlotnik, G

    2008-01-01

    The aim was to evaluate the test-retest reliability of the French translation of the Migraine Disability Assessment (MIDAS) and Headache Impact Test (HIT)-6 questionnaires as applied to episodic and chronic headaches and to assess the correlation between these two questionnaires. The MIDAS and HIT-6 questionnaires, which assess the degree of migraine-related functional disability, are widely used in headache treatment clinics. The French translation has not been checked for test-retest reliability. MIDAS involves recall, over the previous 3 months, of the number of days with functional disability with regard to work and to home and social life. HIT-6 involves a more subjective and general assessment of headache-related disability over the previous 4 weeks. We expect that there may be greater impact recall bias for chronic headaches than for episodic headaches and considered it important to be able to determine if the reliability of these questionnaires is equally good for these two patient populations. Given that both questionnaires have the same objective, that of assessing headache impact, it was thought useful to determine if their results might show a correlation and if they could thus be used interchangeably. The study was approved by an external ethics committee. The subjects were patients who regularly visit the Clinique de la Migraine de Montréal, which specializes in the treatment of headaches. The MIDAS and HIT-6 questionnaires were completed by the patients during their regular visit. Twelve days later, the same questionnaires were mailed with a prepaid return envelope. Sixty-five patients were required in both the episodic and chronic headache groups, assuming an 80% questionnaire return rate. One hundred and eighty-five patients were enrolled, and 143 completed the study, 75 with episodic headaches and 68 with chronic headaches. The questionnaire return rate was 78.9%. On average, questionnaires were completed a second time 21 days after the first

  15. HIT or miss? A comprehensive contemporary investigation of laboratory tests for heparin induced thrombocytopenia.

    Science.gov (United States)

    Favaloro, Emmanuel J; McCaughan, Georgia; Mohammed, Soma; Lau, Kun Kan Edwin; Gemmell, Rosalie; Cavanaugh, Lauren; Donikian, Dea; Kondo, Mayuko; Brighton, Timothy; Pasalic, Leonardo

    2018-04-17

    Heparin induced thrombocytopenia (HIT) is a rare but potentially fatal complication of heparin therapy, which in a proportion of patients causes platelet activation and thrombosis. Initial clinical assessment of the likelihood of HIT is facilitated by laboratory testing to confirm or exclude HIT. This prospective investigation was performed over an 18-month period, and has involved testing of over 300 test samples from over 100 consecutive patients. Clinical assessment by 4T score was supplemented by laboratory tests that comprised both immunological [lateral flow ('STiC'), chemiluminescence (AcuStar; HIT-IgG (PF4-H) ), ELISA (Asserachrom HPIA IgG)] and functional assays [SRA, platelet aggregation using whole blood ('Multiplate') and platelet rich plasma ('LTA')]. We observed both false positive and false negative test findings with most assays. Overall, the whole blood aggregation method provided a reasonable alternative to SRA for identifying functional HIT. STiC, AcuStar and ELISA procedures were fairly comparable in terms of screening for HIT, although STiC and AcuStar both yielded false negatives, albeit also resulting in fewer false positives than ELISA. The 4T score had less utility in our patient cohort than we were expecting, although there was an association with the likelihood of HIT. Nevertheless, we accept that our observations are based on limited test numbers. In conclusion, no single approach (clinical or laboratory) was associated with optimal sensitivity or specificity of HIT exclusion or identification, and thus, a combination of clinical evaluation and laboratory testing will best ensure the accuracy of diagnosis. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  16. Validation of the Impact of Health Information Technology (I-HIT) Scale: an international collaborative.

    Science.gov (United States)

    Dykes, Patricia C; Hurley, Ann C; Brown, Suzanne; Carr, Robyn; Cashen, Margaret; Collins, Rita; Cook, Robyn; Currie, Leanne; Docherty, Charles; Ensio, Anneli; Foster, Joanne; Hardiker, Nicholas R; Honey, Michelle L L; Killalea, Rosaleen; Murphy, Judy; Saranto, Kaija; Sensmeier, Joyce; Weaver, Charlotte

    2009-01-01

    In 2005, the Healthcare Information Management Systems Society (HIMSS) Nursing Informatics Community developed a survey to measure the impact of health information technology (HIT), the I-HIT Scale, on the role of nurses and interdisciplinary communication in hospital settings. In 2007, nursing informatics colleagues from Australia, England, Finland, Ireland, New Zealand, Scotland and the United States formed a research collaborative to validate the I-HIT across countries. All teams have completed construct and face validation in their countries. Five out of six teams have initiated reliability testing by practicing nurses. This paper reports the international collaborative's validation of the I-HIT Scale completed to date.

  17. Effective progression of nuclear magnetic resonance-detected fragment hits.

    Science.gov (United States)

    Eaton, Hugh L; Wyss, Daniel F

    2011-01-01

    Fragment-based drug discovery (FBDD) has become increasingly popular over the last decade as an alternate lead generation tool to HTS approaches. Several compounds have now progressed into the clinic which originated from a fragment-based approach, demonstrating the utility of this emerging field. While fragment hit identification has become much more routine and may involve different screening approaches, the efficient progression of fragment hits into quality lead series may still present a major bottleneck for the broadly successful application of FBDD. In our laboratory, we have extensive experience in fragment-based NMR screening (SbN) and the subsequent iterative progression of fragment hits using structure-assisted chemistry. To maximize impact, we have applied this approach strategically to early- and high-priority targets, and those struggling for leads. Its application has yielded a clinical candidate for BACE1 and lead series in about one third of the SbN/FBDD projects. In this chapter, we will give an overview of our strategy and focus our discussion on NMR-based FBDD approaches. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. HIT Solar Cells with N-Type Low-Cost Metallurgical Si

    Directory of Open Access Journals (Sweden)

    Xing Yang

    2018-01-01

    Full Text Available A conversion efficiency of 20.23% of heterojunction with intrinsic thin layer (HIT solar cell on 156 mm × 156 mm metallurgical Si wafer has been obtained. Applying AFORS-HET software simulation, HIT solar cell with metallurgical Si was investigated with regard to impurity concentration, compensation level, and their impacts on cell performance. It is known that a small amount of impurity in metallurgical Si materials is not harmful to solar cell properties.

  19. Ceres: Dawn visits a Warm Wet Planet

    Science.gov (United States)

    McCord, T. B.; Combe, J. P.

    2014-12-01

    Ceres likely contains considerable water, has differentiated, and formed a hydrated silicate core and water mantle. There were major dimensional, thermal and chemical changes over its history, making it more a planet than an asteroid. These factors created the present day body, which the Dawn misson will visit next March. I will summarize our current understanding of Ceres and suggest what Dawn will find. A major uncertainty is how processes, such as aqueous mineralization, impact and cratering, infall of external material, mixing, and viscous relaxation of surface features have altered the formation materials and surface, hiding Ceres' secrets. Ceres' bulk density of 2100 kg/m3, suggest major water content. Modeling of Ceres' thermodynamic evolution for different times of accretion, assuming several radioactive heating scenarios, produces results ranging from a dry Vestal-like object (earlier, hotter formation) to retention and melting of the ice and differentiation of silicates from liquid water. Mixing of liquid water and silicates leads to exothermic hydration reactions, formation of a core and a liquid mantle. Large dimensional changes are associated. A crust stays frozen but founders at times due to gravitational instability, dimensional changes and impacts. The liquid mantle freezes from top, down, but a layer of salty liquid water probably exists today near the core. Hydrated silicates from the initial differentiation would likely dehydrate near the core center due to temperature and pressure. From observations, only subdued spatial albedo and color variations are observed at UV and IR wavelengths on Ceres' surface at the scale possible from Earth (~50-100 km) and an oblate spheroid shape is found, consistent with a differentiated body. Compositional evidence includes the long known similarity of Ceres' albedo and visual-IR reflectance spectrum to those for carbonaceous chondrite meteorites. Thus, the surface is likely made of carbon-bearing, hydroxolated

  20. Operations Odyssey Dawn and Unified Protector: Another Win for Warden s Theory

    Science.gov (United States)

    2014-12-04

    the aircraft aimed at armoured vehicles just outside Benghazi. At night, US Navy ships and Royal Navy submarine HMS Triumph launched 112 Tomahawk...the vicinity of Zintan: 3 tanks, 1 anti-aircraft weapon system and 1 armoured vehicles were destroyed. In the vicinity of Brega: 1 building was... demographic groups) to be sympathetic and helpful in a variety of ways.”95 For Operations Odyssey Dawn and Unified Protector, the objective was

  1. Biophysics: for HTS hit validation, chemical lead optimization, and beyond.

    Science.gov (United States)

    Genick, Christine C; Wright, S Kirk

    2017-09-01

    There are many challenges to the drug discovery process, including the complexity of the target, its interactions, and how these factors play a role in causing the disease. Traditionally, biophysics has been used for hit validation and chemical lead optimization. With its increased throughput and sensitivity, biophysics is now being applied earlier in this process to empower target characterization and hit finding. Areas covered: In this article, the authors provide an overview of how biophysics can be utilized to assess the quality of the reagents used in screening assays, to validate potential tool compounds, to test the integrity of screening assays, and to create follow-up strategies for compound characterization. They also briefly discuss the utilization of different biophysical methods in hit validation to help avoid the resource consuming pitfalls caused by the lack of hit overlap between biophysical methods. Expert opinion: The use of biophysics early on in the drug discovery process has proven crucial to identifying and characterizing targets of complex nature. It also has enabled the identification and classification of small molecules which interact in an allosteric or covalent manner with the target. By applying biophysics in this manner and at the early stages of this process, the chances of finding chemical leads with novel mechanisms of action are increased. In the future, focused screens with biophysics as a primary readout will become increasingly common.

  2. High-Throughput Screening and Hit Validation of Extracellular-Related Kinase 5 (ERK5) Inhibitors.

    Science.gov (United States)

    Myers, Stephanie M; Bawn, Ruth H; Bisset, Louise C; Blackburn, Timothy J; Cottyn, Betty; Molyneux, Lauren; Wong, Ai-Ching; Cano, Celine; Clegg, William; Harrington, Ross W; Leung, Hing; Rigoreau, Laurent; Vidot, Sandrine; Golding, Bernard T; Griffin, Roger J; Hammonds, Tim; Newell, David R; Hardcastle, Ian R

    2016-08-08

    The extracellular-related kinase 5 (ERK5) is a promising target for cancer therapy. A high-throughput screen was developed for ERK5, based on the IMAP FP progressive binding system, and used to identify hits from a library of 57 617 compounds. Four distinct chemical series were evident within the screening hits. Resynthesis and reassay of the hits demonstrated that one series did not return active compounds, whereas three series returned active hits. Structure-activity studies demonstrated that the 4-benzoylpyrrole-2-carboxamide pharmacophore had excellent potential for further development. The minimum kinase binding pharmacophore was identified, and key examples demonstrated good selectivity for ERK5 over p38α kinase.

  3. In-Flight Operation of the Dawn Ion Propulsion System Through Survey Science Orbit at Ceres

    Science.gov (United States)

    Garner, Charles E.; Rayman, Marc D.

    2015-01-01

    The Dawn mission, part of NASA's Discovery Program, has as its goal the scientific exploration of the two most massive main-belt objects, Vesta and Ceres. The Dawn spacecraft was launched from the Cape Canaveral Air Force Station on September 27, 2007 on a Delta-II 7925H- 9.5 (Delta-II Heavy) rocket that placed the 1218-kg spacecraft onto an Earth-escape trajectory. On-board the spacecraft is an ion propulsion system (IPS) developed at the Jet Propulsion Laboratory which will provide a total delta V of 11 km/s for the heliocentric transfer to Vesta, orbit capture at Vesta, transfer between Vesta science orbits, departure and escape from Vesta, heliocentric transfer to Ceres, orbit capture at Ceres, and transfer between Ceres science orbits. Full-power thrusting from December 2007 through October 2008 was used to successfully target a Mars gravity assist flyby in February 2009 that provided an additional delta V of 2.6 km/s. Deterministic thrusting for the heliocentric transfer to Vesta resumed in June 2009 and concluded with orbit capture at Vesta on July 16, 2011. From July 2011 through September 2012 the IPS was used to transfer to all the different science orbits at Vesta and to escape from Vesta orbit. Cruise for a rendezvous with Ceres began in September 2012 and concluded with the start of the approach to Ceres phase on December 26, 2015, leading to orbit capture on March 6, 2015. Deterministic thrusting continued during approach to place the spacecraft in its first science orbit, called RC3, which was achieved on April 23, 2015. Following science operations at RC3 ion thrusting was resumed for twenty-five days leading to arrival to the next science orbit, called survey orbit, on June 3, 2015. The IPS will be used for all subsequent orbit transfers and trajectory correction maneuvers until completion of the primary mission in approximately June 2016. To date the IPS has been operated for over 46,774 hours, consumed approximately 393 kg of xenon, and provided

  4. Upgrade tracking with the UT Hits

    CERN Document Server

    Gandini, P; Wang, J

    2014-01-01

    The performance of the LHCb tracking system for the upgrade on long tracks is evaluated in terms of efficiency and ghost rate reduction for several different sets of requirements. We find that the efficiency is quite high and that the ghost rate reduction is substantial. We also describe the current algorithm for adding UT hits to the tracks.

  5. ORIGIN: Metal Creation and Evolution from the Cosmic Dawn

    DEFF Research Database (Denmark)

    Herder, J. W. den; Piro, L.; Ohashi, T.

    2011-01-01

    , and beyond. The mission will answer questions such as: When were the first metals created? How does the cosmic metal content evolve? Where do most of the metals reside in the Universe? What is the role of metals in structure formation and evolution? To reach out to the early Universe ORIGIN will use Gamma......ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z=10...

  6. Dawn-dusk asymmetry in particles of solar wind origin within the magnetosphere

    Directory of Open Access Journals (Sweden)

    T. J. Stubbs

    2001-01-01

    Full Text Available Solar wind/magnetosheath plasma in the magnetosphere can be identified using a component that has a higher charge state, lower density and, at least soon after their entry into the magnetosphere, lower energy than plasma from a terrestrial source. We survey here observations taken over 3 years of He2+ ions made by the Magnetospheric Ion Composition Sensor (MICS of the Charge and Mass Magnetospheric Ion Composition Experiment (CAMMICE instrument aboard POLAR. The occurrence probability of these solar wind ions is then plotted as a function of Magnetic Local Time (MLT and invariant latitude (7 for various energy ranges. For all energies observed by MICS (1.8–21.4 keV and all solar wind conditions, the occurrence probabilities peaked around the cusp region and along the dawn flank. The solar wind conditions were filtered to see if this dawnward asymmetry is controlled by the Svalgaard-Mansurov effect (and so depends on the BY component of the interplanetary magnetic field, IMF or by Fermi acceleration of He2+ at the bow shock (and so depends on the IMF ratio BX /BY . It is shown that the asymmetry remained persistently on the dawn flank, suggesting it was not due to effects associated with direct entry into the magnetosphere. This asymmetry, with enhanced fluxes on the dawn flank, persisted for lower energy ions (below a "cross-over" energy of about 23 keV but reversed sense to give higher fluxes on the dusk flank at higher energies. This can be explained by the competing effects of gradient/curvature drifts and the convection electric field on ions that are convecting sunward on re-closed field lines. The lower-energy He2+ ions E × B drift dawnwards as they move earthward, whereas the higher energy ions curvature/ gradient drift towards dusk. The convection electric field in the tail is weaker for northward IMF. Ions then need less energy to drift to the dusk flank, so that the cross-over energy, at which the asymmetry changes sense, is reduced

  7. Gender Bias in The Rural Community as Reflected in Minfong Ho’s Sing to The Dawn

    Directory of Open Access Journals (Sweden)

    Hermanus Wahyaka

    2017-01-01

    Full Text Available This study aims at identifying the evidences of gender-biased behaviour and actions and at finding the possible reasons why those gender-biased behaviour and actions happen within the life of the rural community as depicted in the novel. The problems, therefore, are formulated as follows: 1. What are the evidences of gender-biased behaviour and actions experienced by the major female characters of Ho’sSing to the Dawn?and 2. Why do the gender-biased behaviour and actions occur within the life of the rural communityas in Ho’sSing to the Dawn? This study is a library research. The primary source is the novel itself, Sing to the Dawn. The secondary sources are obtained from several relevant books related to literary theories such as the critical approach, the theory of gender, the theory of society, and the review of Thai society. In order to relate the gender bias and a certain community, the socio-cultural approach is used to examine the novel. This study found that gender biased behaviour and actions committed by the male characters towards the major female characters manifest in several manners; they are subordination of women, mental violence, violent intention, physical violence, sex role stereotyping, and marginalization. The possible reasons enabling the manifestation of gender biased behaviour and actions committed by the male characters towards the major female characters are cultural construction on women subordination, cultural construction on sex roles stereotyping as the result of patriarchal system, religious misinterpretation, and poverty.   DOI: https://doi.org/10.24071/llt.2012.150205

  8. LncRNA-HIT Functions as an Epigenetic Regulator of Chondrogenesis through Its Recruitment of p100/CBP Complexes.

    Science.gov (United States)

    Carlson, Hanqian L; Quinn, Jeffrey J; Yang, Yul W; Thornburg, Chelsea K; Chang, Howard Y; Stadler, H Scott

    2015-12-01

    Gene expression profiling in E 11 mouse embryos identified high expression of the long noncoding RNA (lncRNA), LNCRNA-HIT in the undifferentiated limb mesenchyme, gut, and developing genital tubercle. In the limb mesenchyme, LncRNA-HIT was found to be retained in the nucleus, forming a complex with p100 and CBP. Analysis of the genome-wide distribution of LncRNA-HIT-p100/CBP complexes by ChIRP-seq revealed LncRNA-HIT associated peaks at multiple loci in the murine genome. Ontological analysis of the genes contacted by LncRNA-HIT-p100/CBP complexes indicate a primary role for these loci in chondrogenic differentiation. Functional analysis using siRNA-mediated reductions in LncRNA-HIT or p100 transcripts revealed a significant decrease in expression of many of the LncRNA-HIT-associated loci. LncRNA-HIT siRNA treatments also impacted the ability of the limb mesenchyme to form cartilage, reducing mesenchymal cell condensation and the formation of cartilage nodules. Mechanistically the LncRNA-HIT siRNA treatments impacted pro-chondrogenic gene expression by reducing H3K27ac or p100 activity, confirming that LncRNA-HIT is essential for chondrogenic differentiation in the limb mesenchyme. Taken together, these findings reveal a fundamental epigenetic mechanism functioning during early limb development, using LncRNA-HIT and its associated proteins to promote the expression of multiple genes whose products are necessary for the formation of cartilage.

  9. Modeling the Radio Foreground for Detection of CMB Spectral Distortions from the Cosmic Dawn and the Epoch of Reionization

    Energy Technology Data Exchange (ETDEWEB)

    Sathyanarayana Rao, Mayuri; Subrahmanyan, Ravi; Shankar, N Udaya [Raman Research Institute, C V Raman Avenue, Sadashivanagar, Bangalore 560080 (India); Chluba, Jens, E-mail: mayuris@rri.res.in [Jodrell Bank Centre for Astrophysics, University of Manchester, Oxford Road, M13 9PL (United Kingdom)

    2017-05-01

    Cosmic baryon evolution during the Cosmic Dawn and Reionization results in redshifted 21-cm spectral distortions in the cosmic microwave background (CMB). These encode information about the nature and timing of first sources over redshifts 30–6 and appear at meter wavelengths as a tiny CMB distortion along with the Galactic and extragalactic radio sky, which is orders of magnitude brighter. Therefore, detection requires precise methods to model foregrounds. We present a method of foreground fitting using maximally smooth (MS) functions. We demonstrate the usefulness of MS functions over traditionally used polynomials to separate foregrounds from the Epoch of Reionization (EoR) signal. We also examine the level of spectral complexity in plausible foregrounds using GMOSS, a physically motivated model of the radio sky, and find that they are indeed smooth and can be modeled by MS functions to levels sufficient to discern the vanilla model of the EoR signal. We show that MS functions are loss resistant and robustly preserve EoR signal strength and turning points in the residuals. Finally, we demonstrate that in using a well-calibrated spectral radiometer and modeling foregrounds with MS functions, the global EoR signal can be detected with a Bayesian approach with 90% confidence in 10 minutes’ integration.

  10. Evaluation of flow cytometric HIT assays in relation to an IgG-Specific immunoassay and clinical outcome.

    Science.gov (United States)

    Kerényi, Adrienne; Beke Debreceni, Ildikó; Oláh, Zsolt; Ilonczai, Péter; Bereczky, Zsuzsanna; Nagy, Béla; Muszbek, László; Kappelmayer, János

    2017-09-01

    Heparin-induced thrombocytopenia (HIT) is a severe side effect of heparin treatment caused by platelet activating IgG antibodies generated against the platelet factor 4 (PF4)-heparin complex. Thrombocytopenia and thrombosis are the leading clinical symptoms of HIT. The clinical pretest probability of HIT was evaluated by the 4T score system. Laboratory testing of HIT was performed by immunological detection of antibodies against PF4-heparin complex (EIA) and two functional assays. Heparin-dependent activation of donor platelets by patient plasma was detected by flow cytometry. Increased binding of Annexin-V to platelets and elevated number of platelet-derived microparticles (PMP) were the indicators of platelet activation. EIA for IgG isotype HIT antibodies was performed in 405 suspected HIT patients. Based on negative EIA results, HIT was excluded in 365 (90%) of cases. In 40 patients with positive EIA test result functional tests were performed. Platelet activating antibodies were detected in 17 cases by Annexin V binding. PMP count analysis provided nearly identical results. The probability of a positive flow cytometric assay result was higher in patients with elevated antibody titer. 71% of patients with positive EIA and functional assay had thrombosis. EIA is an important first line laboratory test in the diagnosis of HIT; however, HIT must be confirmed by a functional test. Annexin V binding and PMP assays using flow cytometry are functional HIT tests convenient in a clinical diagnostic laboratory. The positive results of functional assays may predict the onset of thrombosis. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  11. Possilibity of estimating payoff matrix from model for hit phenomena

    International Nuclear Information System (INIS)

    Ishii, Akira; Sakaidani, Shota; Iwanaga, Saori

    2016-01-01

    The conflicts of topics on social media is considered using an extended mathematical model based on the mathematical model for hit phenomena that has been used to analyze entertainment hits. The social media platform used in this study was blog. The calculation results shows examples of strong conflict, weak conflict, and no conflict cases. Since the conflict of two topics can be considered in the framework of game theory, the results can be used to determine each matrix element of the payoff matrix of game theory.

  12. Visual Illusions and the Control of Ball Placement in Goal-Directed Hitting

    Science.gov (United States)

    Caljouw, Simone R.; Van der Kamp, John; Savelsbergh, Geert J. P.

    2010-01-01

    When hitting, kicking, or throwing balls at targets, online control in the target area is impossible. We assumed this lack of late corrections in the target area would induce an effect of a single-winged Muller-Lyer illusion on ball placement. After extensive practice in hitting balls to different landing locations, participants (N = 9) had to hit…

  13. Aggressive B cell Lymphoma: Optimal Therapy for MYC-positive, Double-Hit, and Triple-Hit DLBCL.

    Science.gov (United States)

    Dunleavy, Kieron

    2015-12-01

    Approximately 10% of cases of diffuse large B cell lymphoma (DLBCL) harbor a MYC rearrangement and this has been associated with an inferior outcome following standard therapy across many different studies. Double-hit and triple-hit lymphomas harbor concurrent rearrangements of MYC and BCL2 and/or BCL6 and are also associated with a very aggressive course and poor clinical outcome. It is unclear and there is lack of consensus on how these diseases should be approached therapeutically. They are characterized typically by high tumor proliferation and likely require Burkitt lymphoma-type strategies and several retrospective studies suggest that more intensive approaches than rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone (R-CHOP) may be beneficial. One challenge in this respect is that most patients with these diseases are older than 60 years and generally have poor tolerability of regimens typically used in Burkitt lymphoma. Dose-adjusted EPOCH-R is an alternative effective immunochemotherapy platform for DLBCL and is effective in Burkitt lymphoma, and retrospective studies suggest that it is effective and feasible in patients with DLBCL that harbors a MYC rearrangement with or without a BCL-2 translocation (double-hit). A multicenter study of this approach in MYC-rearranged DLBCL is ongoing and preliminary results are very encouraging. There is a lack of consensus on the role of consolidation stem cell transplantation in patients who achieve a good response to initial therapy but at this point in time, no (retrospective) studies have demonstrated any benefit. These diseases are also associated with a high rate of CNS involvement and progression and checking for cerebrospinal fluid by cytology and flow cytometry at initial diagnosis should be considered. In summary, based on retrospective data and preliminary prospective data (as more mature data is awaited), while Burkitt-type regimens may be feasible in young patients, DA-EPOCH-R is a

  14. Simulation optimizing of n-type HIT solar cells with AFORS-HET

    Science.gov (United States)

    Yao, Yao; Xiao, Shaoqing; Zhang, Xiumei; Gu, Xiaofeng

    2017-07-01

    This paper presents a study of heterojunction with intrinsic thin layer (HIT) solar cells based on n-type silicon substrates by a simulation software AFORS-HET. We have studied the influence of thickness, band gap of intrinsic layer and defect densities of every interface. Details in mechanisms are elaborated as well. The results show that the optimized efficiency reaches more than 23% which may give proper suggestions to practical preparation for HIT solar cells industry.

  15. Machine Learning Applied to Dawn/VIR data of Vesta in view of MERTIS/BepiColombo.

    Science.gov (United States)

    Helbert, J.; D'Amore, M.; Le Scaon, R.; Maturilli, A.; Palomba, E.; Longobardo, A.; Hiesinger, H.

    2016-12-01

    Remote sensing spectroscopy is one of the most commonly used technique in planetary science and for recent instruments producing huge amount of data, classic methods could fails to unlock the full scientific potential buried in the measurements. We explored several Machine Learning techniques: multi-step clustering method is developed, using an image segmentation method, a stream algorithm, and hierarchical clustering. The MErcury Radiometer and Thermal infrared Imaging Spectrometer (MERTIS) is part of the payload of the Mercury Planetary Orbiter spacecraft of the ESA-JAXA BepiColombo mission. MERTIS's scientific goals are to infer rock-forming minerals, to map surface composition, and to study surface temperature variations on Mercury. The NASA mission DAWN carry a suites of instruments aimed at understanding the two most massive objects in the main asteroid belt: Vesta and Ceres. DAWN has already successfully completed the exploration of Vesta in September 2012 and it is now in the last phase of the mission around Ceres. To cope with the stream of data that will be delivered by MERTIS, we developed an algorithm that could aggregate new data as they come in during the mission giving the scientist a guide for the most interesting and new discovery on Mercury. The DAWN/VESTA VIR data is a testbed for the algorithm. The algorithm identified the Olivine outcrops around two craters on Vesta's surface described in Ammannito et al., 2013. We furthermore mimic the data acquisition process as if the mission were dumping the data live. The algorithm provides insightful information on the novelty and classes int he data as they are collected. This will enhance MERTIS targeting and maximize its scientific return during BepiColombo mission at Mercury. E Ammannito et al. "Olivine in an unexpected location on Vesta/'s surface". In: Nature 504.7478 (2013), pp. 122-125.

  16. Assessment of the performances of AcuStar HIT and the combination with heparin-induced multiple electrode aggregometry: a retrospective study.

    Science.gov (United States)

    Minet, V; Bailly, N; Douxfils, J; Osselaer, J C; Laloy, J; Chatelain, C; Elalamy, I; Chatelain, B; Dogné, J M; Mullier, F

    2013-09-01

    Early diagnosis of immune heparin-induced thrombocytopenia (HIT) is challenging. HemosIL® AcuStar HIT and heparin-induced multiple electrode aggregometry (HIMEA) were recently proposed as rapid diagnostic methods. We conducted a study to assess performances of AcuStar HIT-IgG (PF4-H) and AcuStar HIT-Ab (PF4-H). The secondary objective was to compare the performances of the combination of Acustar HIT and HIMEA with standardised clinical diagnosis. Sera of 104 suspected HIT patients were retrospectively tested with AcuStar HIT. HIMEA was performed on available sera (n=81). The clinical diagnosis was established by analysing in a standardized manner the patient's medical records. These tests were also compared with PF4-Enhanced®, LTA, and SRA in subsets of patients. Thresholds were determined using ROC curve analysis with clinical outcome as reference. Using the recommended thresholds (1.00AU), the negative predictive value (NPV) of HIT-IgG and HIT-Ab were 100.0% (95% CI: 95.9%-100.0% and 95.7%-100.0%). The positive predictive value (PPV) were 64.3% (95% CI: 35.1%-87.2.2%) and 45.0% (95% CI: 23.2%-68.6%), respectively. Using our thresholds (HIT-IgG: 2.89AU, HIT-Ab: 9.41AU), NPV of HIT-IgG and HIT-Ab were 100.0% (95% CI: 96.0%-100.0% and 96.1%-100.0%). PPV were 75.0% (95% CI: 42.7%-94.5%) and 81.8% (95% CI: 48.3%-97.7%), respectively. Of the 79 patients with a medium-high pretest probability score, 67 were negative using HIT-IgG (PF4-H) test at our thresholds. HIMEA was performed on HIT-IgG positive patients. Using this combination, only one patient on 79 was incorrectly diagnosed. Acustar HIT showed good performances to exclude the diagnosis of HIT. Combination with HIMEA improves PPV. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Before the dawn recovering the lost history of our ancestors

    CERN Document Server

    Wade, Nicholas

    2007-01-01

    Nicholas Wade’s articles are a major reason why the science section has become the most popular, nationwide, in the New York Times. In his groundbreaking Before the Dawn, Wade reveals humanity’s origins as never before—a journey made possible only recently by genetic science, whose incredible findings have answered such questions as: What was the first human language like? How large were the first societies, and how warlike were they? When did our ancestors first leave Africa, and by what route did they leave? By eloquently solving these and numerous other mysteries, Wade offers nothing less than a uniquely complete retelling of a story that began 500 centuries ago.

  18. Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance

    Directory of Open Access Journals (Sweden)

    Sharma Neha Gupta

    2015-12-01

    Full Text Available The J-PET detector being developed at the Jagiellonian University is a positron emission tomograph composed of the long strips of polymer scintillators. At the same time, it is a detector system that will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit time and hit position of the gamma quantum. In order to take advantage of this fact, a dedicated sampling front-end electronics that enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity, we use the Mahalanobis distance. The achievable position and time resolution depend on the number and values of the threshold levels at which the signal is sampled. A reconstruction method as well as preliminary results are presented and discussed.

  19. Intruders: New Neighbors in "Dawn of the Planet of the Apes" and "The Hundred-Foot Journey"

    Science.gov (United States)

    Beck, Bernard

    2015-01-01

    Conflicts over territory are about the power to establish dominant cultures in territories and are often accompanied by cultural claims to legitimacy by each side. The cultural claims, or ideologies, are often expressed in terms of "homeland" dwellers versus "intruders." Two recent movies, "Dawn of the Planet of the…

  20. USER FRUSTRATION IN HIT INTERFACES: EXPLORING PAST HCI RESEARCH FOR A BETTER UNDERSTANDING OF CLINICIANS' EXPERIENCES.

    Science.gov (United States)

    Opoku-Boateng, Gloria A

    2015-01-01

    User frustration research has been one way of looking into clinicians' experience with health information technology use and interaction. In order to understand how clinician frustration with Health Information Technology (HIT) use occurs, there is the need to explore Human-Computer Interaction (HCI) literature that addresses both frustration and HIT use. In the past three decades, HCI frustration research has increased and expanded. Researchers have done a lot of work to understand emotions, end-user frustration and affect. This paper uses a historical literature review approach to review the origins of emotion and frustration research and explore the research question; Does HCI research on frustration provide insights on clinicians' frustration with HIT interfaces? From the literature review HCI research on emotion and frustration provides additional insights that can indeed help explain user frustration in HIT. Different approaches and HCI perspectives also help frame HIT user frustration research as well as inform HIT system design. The paper concludes with a suggested directions on how future design and research may take.

  1. PLEIADES ABSOLUTE CALIBRATION : INFLIGHT CALIBRATION SITES AND METHODOLOGY

    Directory of Open Access Journals (Sweden)

    S. Lachérade

    2012-07-01

    Full Text Available In-flight calibration of space sensors once in orbit is a decisive step to be able to fulfil the mission objectives. This article presents the methods of the in-flight absolute calibration processed during the commissioning phase. Four In-flight calibration methods are used: absolute calibration, cross-calibration with reference sensors such as PARASOL or MERIS, multi-temporal monitoring and inter-bands calibration. These algorithms are based on acquisitions over natural targets such as African deserts, Antarctic sites, La Crau (Automatic calibration station and Oceans (Calibration over molecular scattering or also new extra-terrestrial sites such as the Moon and selected stars. After an overview of the instrument and a description of the calibration sites, it is pointed out how each method is able to address one or several aspects of the calibration. We focus on how these methods complete each other in their operational use, and how they help building a coherent set of information that addresses all aspects of in-orbit calibration. Finally, we present the perspectives that the high level of agility of PLEIADES offers for the improvement of its calibration and a better characterization of the calibration sites.

  2. Informing the Selection of Screening Hit Series with in Silico Absorption, Distribution, Metabolism, Excretion, and Toxicity Profiles.

    Science.gov (United States)

    Sanders, John M; Beshore, Douglas C; Culberson, J Christopher; Fells, James I; Imbriglio, Jason E; Gunaydin, Hakan; Haidle, Andrew M; Labroli, Marc; Mattioni, Brian E; Sciammetta, Nunzio; Shipe, William D; Sheridan, Robert P; Suen, Linda M; Verras, Andreas; Walji, Abbas; Joshi, Elizabeth M; Bueters, Tjerk

    2017-08-24

    High-throughput screening (HTS) has enabled millions of compounds to be assessed for biological activity, but challenges remain in the prioritization of hit series. While biological, absorption, distribution, metabolism, excretion, and toxicity (ADMET), purity, and structural data are routinely used to select chemical matter for further follow-up, the scarcity of historical ADMET data for screening hits limits our understanding of early hit compounds. Herein, we describe a process that utilizes a battery of in-house quantitative structure-activity relationship (QSAR) models to generate in silico ADMET profiles for hit series to enable more complete characterizations of HTS chemical matter. These profiles allow teams to quickly assess hit series for desirable ADMET properties or suspected liabilities that may require significant optimization. Accordingly, these in silico data can direct ADMET experimentation and profoundly impact the progression of hit series. Several prospective examples are presented to substantiate the value of this approach.

  3. A Study on the Type of School during the Dawn of Modern Education in Bhutan

    Science.gov (United States)

    Hirayama, Takehiro

    2015-01-01

    This study aims to clarify the state of school education in the Bhutan during the 1940-50s, a period of dawn of the modern education in Bhutan, by classifying schools and identifying their contrasting characteristics. The origins of modern education in Bhutan can be traced back approximately 100 years. Bhutan's modern period began in 1907 when…

  4. HIT or miss: the application of health care information technology to managing uncertainty in clinical decision making.

    Science.gov (United States)

    Kazandjian, Vahé A; Lipitz-Snyderman, Allison

    2011-12-01

    To discuss the usefulness of health care information technology (HIT) in assisting care providers minimize uncertainty while simultaneously increasing efficiency of the care provided. An ongoing study of HIT, performance measurement (clinical and production efficiency) and their implications to the payment for care represents the design of this study. Since 2006, all Maryland hospitals have embarked on a multi-faceted study of performance measures and HIT adoption surveys, which will shape the health care payment model in Maryland, the last of the all-payor states, in 2011. This paper focuses on the HIT component of the Maryland care payment initiative. While the payment model is still under review and discussion, 'appropriateness' of care has been discussed as an important dimension of measurement. Within this dimension, the 'uncertainty' concept has been identified as associated with variation in care practices. Hence, the methods of this paper define how HIT can assist care providers in addressing the concept of uncertainty, and then provides findings from the first HIT survey in Maryland to infer the readiness of Maryland hospital in addressing uncertainty of care in part through the use of HIT. Maryland hospitals show noteworthy variation in their adoption and use of HIT. While computerized, electronic patient records are not commonly used among and across Maryland hospitals, many of the uses of HIT internally in each hospital could significantly assist in better communication about better practices to minimize uncertainty of care and enhance the efficiency of its production. © 2010 Blackwell Publishing Ltd.

  5. Hit Dexter: A Machine-Learning Model for the Prediction of Frequent Hitters.

    Science.gov (United States)

    Stork, Conrad; Wagner, Johannes; Friedrich, Nils-Ole; de Bruyn Kops, Christina; Šícho, Martin; Kirchmair, Johannes

    2018-03-20

    False-positive assay readouts caused by badly behaving compounds-frequent hitters, pan-assay interference compounds (PAINS), aggregators, and others-continue to pose a major challenge to experimental screening. There are only a few in silico methods that allow the prediction of such problematic compounds. We report the development of Hit Dexter, two extremely randomized trees classifiers for the prediction of compounds likely to trigger positive assay readouts either by true promiscuity or by assay interference. The models were trained on a well-prepared dataset extracted from the PubChem Bioassay database, consisting of approximately 311 000 compounds tested for activity on at least 50 proteins. Hit Dexter reached MCC and AUC values of up to 0.67 and 0.96 on an independent test set, respectively. The models are expected to be of high value, in particular to medicinal chemists and biochemists who can use Hit Dexter to identify compounds for which extra caution should be exercised with positive assay readouts. Hit Dexter is available as a free web service at http://hitdexter.zbh. uni-hamburg.de. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. HitRECord: Cultura remix y copyright. Una experiencia en primera persona en el interior de la Compañía de Producción hitRECord.

    OpenAIRE

    Sabater Planelles, Pablo

    2016-01-01

    El Proyecto que hemos desarrollado, mezcla investigación y experiencia en primera persona entorno a dos temas principales con la finalidad de abordarlos, experimentarlos y comprenderlos de la mejor manera en el contexto actual. Mantienen una estrecha confrontación entre ellos y gran relación con la comunidad online hitRECord. Éstos son el copyright y la cultura remix. HitRECord es una plataforma online impulsada en el 2010 por el actor y artista Joseph Gordon-Levitt, convertida en una ...

  7. Development of pulsation technique for single ion hit system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Takuro; Hamano, Tsuyoshi; Hirao, Toshio; Kamiya, Tomihiro [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1996-12-01

    When a high energy heavy ion enters into a substance, high density of ionization and excitement occurrs along its flying trace. Especially, when such an ion enters into a semiconductor cell, a bit inversion called single event is occurred or a phenomenon destroyed element itself on case of the worst is formed. The present semiconductor cell is made in a size of some micron square, as different from its accumulated degree. In order to analyze the single event phenomenon formed by entering ion into such fine region in detail, a technique possible enter heavy ion beam with space resolution under 1 micron to each sample is necessary. In order to develop this technique, a static type high speed beam switch for control of entering a beam into a sample and a single ion detector for detecting entrance of ion into the sample were installed to heavy ion microbeam forming apparatus. The single ion hit system in Takasaki Radiation Chemistry Research Establishment, JAERI succeeded in detection and control technique of the single ion and control of noise due to pulsization and finished development of basic technique of the single ion hit, since now. After today, it is planned to hit actually the single ion onto the sample and evaluate its accuracy. (G.K.)

  8. Biomarkers for IgA nephropathy on the basis of multi-hit pathogenesis.

    Science.gov (United States)

    Suzuki, Hitoshi

    2018-05-08

    IgA nephropathy (IgAN) is the most prevalent glomerular disease worldwide and is associated with a poor prognosis. Development of curative treatment strategies and approaches for early diagnosis is necessary. Renal biopsy is the gold standard for the diagnosis and assessment of disease activity. However, reliable biomarkers are needed for the noninvasive diagnosis of this disease and to more fully delineate the risk of progression. With regard to the pathogenesis of IgAN, the multi-hit hypothesis, including production of galactose-deficient IgA1 (Gd-IgA1; Hit 1), IgG or IgA autoantibodies that recognize Gd-IgA1 (Hit 2), and their subsequent immune complexes formation (Hit 3) and glomerular deposition (Hit 4), has been widely supported by many studies. Although the prognostic values of several biomarkers have been discussed, we recently developed a highly sensitive and specific diagnostic method by measuring serum levels of Gd-IgA1 and Gd-IgA1-containing immune complexes. In addition, urinary Gd-IgA1 may represent a disease-specific biomarker for IgAN. We also confirmed that there is a significant correlation between serum levels of these effector molecules and disease activity, suggesting that each can be considered a practical surrogate marker of therapeutic response. Thus, these disease-oriented specific serum and urine biomarkers may be useful for screening of potential IgAN with isolated hematuria, earlier diagnosis, disease activity, and eventually, response to treatment. In this review, we discuss these concepts, with a focus on potential clinical applications of these biomarkers.

  9. Dual hit lipopolysaccharide & oleic acid combination induced rat model of acute lung injury/acute respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    T N Hagawane

    2016-01-01

    Results: It was noted that the respiratory rate, and tumour necrosis factor-α (TNF-α levels were significantly higher at 4 h in the dual hit group as compared to LPS, OA and control groups. Interleukin-6 (IL-6 levels were significantly higher in the dual hit group as compared to LPS at 8 and 24 h, OA at 8 h and control (at all time intervals group. IL-1β levels were significantly higher in LPS and dual hit groups at all time intervals, but not in OA and control groups. The injury induced in dual hit group was earlier and more sustained as compared to LPS and OA alone. Interpretation & conclusions: The lung pathology and changes in respiration functions produced by the dual hit model were closer to the diagnostic criteria of ALI/ARDS in terms of clinical manifestations and pulmonary injury and the injury persisted longer as compared to LPS and OA single hit model. Therefore, the ARDS model produced by the dual hit method was closer to the diagnostic criteria of ARDS in terms of clinical manifestations and pulmonary injury.

  10. Hit-size effectiveness theory applied to high doses of low LET radiation for pink mutations in Tradescantia

    International Nuclear Information System (INIS)

    Varma, M.N.; Bond, V.P.; Matthews, G.

    1985-01-01

    A hit-size effectiveness function which represents the probability of inducing a pink mutation in Tradescantia as a function of lineal energy density has been obtained (1) using observed pink mutation data for seven different radiation qualities and their respective single event microdosimetric spectra. In obtaining this function only the linear portions of dose-response curves were used. A significant improvement of the concepts embodied in the proposed hit-size effectiveness theory would be the demonstration of its applicability at high doses (where multiple hits are produced) and high dose rates (at which no significant biological repair takes place). In this article details are given on preliminary calculations of the pink mutation frequency in Tradescantia at 1, 5, 10, 20, and 60 rads for 250 kVp x rays, using the multi-hit spectra and the hit-size effectiveness function obtained on the basis of single hit microdosimetric spectra as outline in (1). A comparison of the calculated and observed pink mutation frequencies indicate excellent agreement and suggests the possibility of obtaining the hit-size effectiveness function from high dose biological-effect data obtained using low-LET radiations. 6 refs., 3 figs., 3 tabs

  11. Gorlin syndrome with an ovarian leiomyoma associated with a PTCH1 second hit.

    Science.gov (United States)

    Akizawa, Yoshika; Miyashita, Toshiyuki; Sasaki, Ryo; Nagata, Reiko; Aoki, Ryoko; Ishitani, Ken; Nagashima, Yoji; Matsui, Hideo; Saito, Kayoko

    2016-04-01

    We describe a Gorlin syndrome (GS) case with two different second hit mutations of PTCH1, one in a keratocystic odontogenic tumor (KCOT) and the other in an ovarian leiomyoma. GS is a rare genetic condition manifesting as multiple basal cell nevi associated with other features such as medulloblastomas, skeletal abnormalities, and ovarian fibromas. A 21-year-old Japanese woman with a history of two KCOTs was diagnosed with GS according to clinical criteria. A PTCH1 mutation, c.1427del T, was detected in peripheral blood. A novel PTCH1 mutation, c.264_265insAATA, had been found in the maxillary KCOT as a second hit mutation. More recently, the ovarian tumor was detected during a gynecological examination. Laparoscopic adnexectomy was performed, and the pathological diagnosis of the ovarian tumor was leiomyoma. Interestingly, another novel mutation, loss of heterozygosity spanning from 9q22.32 to 9q31.2, including PTCH1 and 89 other genes, was detected in this ovarian tumor, providing evidence of a second hit mutation. This is the first report describing a GS-associated ovarian tumor carrying a second hit in the PTCH1 region. We anticipate that accumulation of more cases will clarify the importance of second hit mutations in ovarian tumor formation in GS. © 2016 Wiley Periodicals, Inc.

  12. 77 FR 8943 - Culturally Significant Objects Imported for Exhibition Determinations: “The Dawn of Egyptian Art”

    Science.gov (United States)

    2012-02-15

    ... Determinations: ``The Dawn of Egyptian Art'' SUMMARY: Notice is hereby given of the following determinations... Egyptian Art,'' imported from abroad for temporary exhibition within the United States, are of cultural... of Art, New York, NY from on or about April 2, 2012, until on or about August 5, 2012, and at...

  13. Dawn-dusk asymmetry in particles of solar wind origin within the magnetosphere

    Directory of Open Access Journals (Sweden)

    T. J. Stubbs

    Full Text Available Solar wind/magnetosheath plasma in the magnetosphere can be identified using a component that has a higher charge state, lower density and, at least soon after their entry into the magnetosphere, lower energy than plasma from a terrestrial source. We survey here observations taken over 3 years of He2+ ions made by the Magnetospheric Ion Composition Sensor (MICS of the Charge and Mass Magnetospheric Ion Composition Experiment (CAMMICE instrument aboard POLAR. The occurrence probability of these solar wind ions is then plotted as a function of Magnetic Local Time (MLT and invariant latitude (7 for various energy ranges. For all energies observed by MICS (1.8–21.4 keV and all solar wind conditions, the occurrence probabilities peaked around the cusp region and along the dawn flank. The solar wind conditions were filtered to see if this dawnward asymmetry is controlled by the Svalgaard-Mansurov effect (and so depends on the BY component of the interplanetary magnetic field, IMF or by Fermi acceleration of He2+ at the bow shock (and so depends on the IMF ratio BX /BY . It is shown that the asymmetry remained persistently on the dawn flank, suggesting it was not due to effects associated with direct entry into the magnetosphere. This asymmetry, with enhanced fluxes on the dawn flank, persisted for lower energy ions (below a "cross-over" energy of about 23 keV but reversed sense to give higher fluxes on the dusk flank at higher energies. This can be explained by the competing effects of gradient/curvature drifts and the convection electric field on ions that are convecting sunward on re-closed field lines. The lower-energy He2+ ions E × B drift dawnwards as they move earthward, whereas the higher energy ions curvature/ gradient drift towards dusk. The convection electric field in the tail is weaker for

  14. Double-hit lymphomas constitute a highly aggressive subgroup in diffuse large B-cell lymphomas in the era of rituximab.

    Science.gov (United States)

    Kobayashi, Tsutomu; Tsutsumi, Yasuhiko; Sakamoto, Natsumi; Nagoshi, Hisao; Yamamoto-Sugitani, Mio; Shimura, Yuji; Mizutani, Shinsuke; Matsumoto, Yosuke; Nishida, Kazuhiro; Horiike, Shigeo; Asano, Naoko; Nakamura, Shigeo; Kuroda, Junya; Taniwaki, Masafumi

    2012-11-01

    The incorporation of rituximab in immunochemotherapy has improved treatment outcomes for diffuse large B-cell lymphoma, but the prognosis for some diffuse large B-cell lymphomas remains dismal. Identification of adverse prognostic subgroups is essential for the choice of appropriate therapeutic strategy. We retrospectively investigated the impact of so-called 'double-hit' cytogenetic abnormalities, i.e. cytogenetic abnormalities involving c-MYC co-existing with other poor prognostic cytogenetic abnormalities involving BCL2, BCL6 or BACH2, on treatment outcomes for 93 consecutive diffuse large B-cell lymphoma patients. According to the revised international prognostic index, no patients were cytogenetically diagnosed with double-hit lymphomas in the 'very good' risk group or in the 'good' risk group, while 5 of 33 patients had double-hit lymphomas in the 'poor' risk group. All the double-hit lymphoma patients possessed both nodal and extranodal involvement. The overall complete response rate was 89.3%, overall survival 87.1% and progression-free survival 75.8% over 2 years (median observation period: 644 days). The complete response rates were 93.2% for the non-double-hit lymphoma patients and 40.0% for the double-hit lymphoma patients. Significantly longer progression-free survival and overall survival were observed for the 'very good' and the 'good' risk patients than for the 'poor' risk patients. Moreover, the progression-free survival of double-hit lymphoma was significantly shorter than that of the non-double-hit lymphoma 'poor' risk patients (P = 0.016). In addition, the overall survival of the double-hit lymphoma patients also tended to be shorter than that of the non-double-hit lymphoma 'poor' risk group. The diagnosis of double-hit lymphoma can help discriminate a subgroup of highly aggressive diffuse large B-cell lymphomas and indicate the need for the development of novel therapeutic strategies for double-hit lymphoma.

  15. PF4-HIT antibody (KKO) complexes activate broad innate immune and inflammatory responses.

    Science.gov (United States)

    Haile, Lydia A; Rao, Roshni; Polumuri, Swamy K; Arepally, Gowthami M; Keire, David A; Verthelyi, Daniela; Sommers, Cynthia D

    2017-11-01

    Heparin-induced thrombocytopenia (HIT) is an immune-mediated complication of heparin anticoagulation therapy resulting in thrombocytopenia frequently accompanied by thrombosis. Current evidence suggests that HIT is associated with antibodies developed in response to multi-molecular complexes formed by platelet factor 4 (PF4) bound to heparin or cell surface glycosaminoglycans. These antibody complexes activate platelets and monocytes typically through FcγRIIA receptors increasing the production of PF4, inflammatory mediators, tissue factor and thrombin. The influence of underlying events in HIT including complex-induced pro-inflammatory cell activation and structural determinants leading to local inflammatory responses are not fully understood. The stoichiometry and complex component requirements were determined by incubating fresh peripheral blood mononuclear cells (PBMC) with different concentrations of unfractionated heparin (H), low molecular weight heparin (LMWH), PF4- and anti-PF4-H complex antibodies (KKO). Cytokine mRNA or protein were measured by qRT-PCR or Meso Scale Discovery technology, respectively. Gene expression profile analysis for 594 genes was performed using Nanostring technology and analyzed using Ingenuity Pathway Analysis software. The data show that antibodies magnify immune responses induced in PBMCs by PF4 alone or in complex with heparin or LMWH. We propose that following induction of HIT antibodies by heparin-PF4 complexes, binding of the antibodies to PF4 is sufficient to induce a local pro-inflammatory response which may play a role in the progression of HIT. In vitro assays using PBMCs may be useful in characterizing local inflammatory and innate immune responses induced by HIT antibodies in the presence of PF4 and different sources of heparins. The findings and conclusions in this article are solely the responsibility of the authors and are not being formally disseminated by the Food and Drug Administration. Thus, they should not be

  16. Measurements and Simulations on the Mechanisms of Efficiency Losses in HIT Solar Cells

    Directory of Open Access Journals (Sweden)

    Silvio Pierro

    2015-01-01

    Full Text Available We study the electrical and the optical behavior of HIT solar cell by means of measurements and optoelectrical simulations by TCAD simulations. We compare the HIT solar cell with a conventional crystalline silicon solar cell to identify the strengths and weaknesses of the HIT technology. Results highlight different mechanisms of electrical and optical efficiency losses caused by the presence of the amorphous silicon layer. The higher resistivity of the a-Si layers implies a smaller distance between the metal lines that causes a higher shadowing. The worst optical coupling between the amorphous silicon and the antireflective coating implies a slight increase of reflectivity around the 600 nm wavelength.

  17. Lessons learnt from the Wenchuan earthquake: performance evaluation of treatment of critical injuries in hardest-hit areas.

    Science.gov (United States)

    Jiang, Jie; Li, Youping; Huang, Xiaolin; Li, Bing; Su, Lin; Zhong, Dake; Shi, Chenghu; Li, Mingxu; Shan, Juan; Chen, Yin

    2012-08-01

    Critical injury treatment in the hardest-hit areas after a great earthquake was retrospectively analyzed to determine how best to reduce mortality and disability and increase the rehabilitation rate through postquake medical relief. Retrospective analysis, primary sources, and secondary sources were comprehensively retrieved and analyzed. According to incomplete data, 30,620 injured were rescued by themselves among the hardest-hit areas in the 72 hours immediately following the earthquake. Critically injured patients accounted for 22% of total inpatients. Mortality rates declined with greater distance from the epicenter: rates were 12.21% for municipal healthcare centers in the hardest-hit areas, 4.50% for municipal medical units in peripheral quake-hit areas, 2.50% for provincial medical units in peripheral quake-hit areas, and 2.17% for Ministry of Health-affiliated hospitals in peripheral quake-hit areas. The number of injured with fractures on body, limbs or unknown-parts, severe conditions as well as other kinds of non-traumatic diseases received in second-line hospitals was much more than those treated in first-line hospitals with more severe injuries. Among 10,373 injured in stable condition transferred to third-line hospitals, 99.07% were discharged from hospitals within four months, while the mortality rate was 0.017%. The medical relief model of "supervising body helping subordinate unit, severely stricken areas assisting hardest-hit areas, least-hit areas supporting both hardest-hit and severely stricken areas, and self help and mutual assistance applied between hardest-hit areas" was roughly established for injured from severely stricken areas after the Wenchuan Earthquake. The "four-centralization" treatment principle, which referred to concentrating patients, experts, resources and treatment for those injured in critical condition effectively reduced the mortality from 15.06% to 2.9%. Timely, scientific, and standard on-site triage and postmedical

  18. Plasma bubbles near the dawn terminator in the topside ionosphere

    International Nuclear Information System (INIS)

    Burke, W.J.

    1979-01-01

    The physical properties of plasma bubbles in the topside ionosphere near the dawn terminator are investigated. It is assumed that the bubbles result from either a Rayleigh-Taylor or an E X B instability on the bottom side of the F-layer. While the E-region is in darkness, the top and bottomsides of the ionospheres are electrically decoupled and the motion of the bubbles can be described by non-linear, two-dimensional theory. After sunrise, electric fields within the bubbles discharge through the conducting lower ionosphere. The upward drift of the bubbles is effectively halted. To achieve a dayside state of diffusive equilibrium the bubbles slowly begin to collapse from the bottom. (author)

  19. The Holistic Integrity Test (HIT - quantified resilience analysis

    Directory of Open Access Journals (Sweden)

    Dobson Mike

    2016-01-01

    Full Text Available The Holistic Integrity Test (HIT - Quantified Resilience Analysis. Rising sea levels and wider climate change mean we face an increasing risk from flooding and other natural hazards. Tough economic times make it difficult to economically justify or afford the desired level of engineered risk reduction. Add to this significant uncertainty from a range of future predictions, constantly updated with new science. We therefore need to understand not just how to reduce the risk, but what could happen should above design standard events occur. In flood terms this includes not only the direct impacts (damage and loss of life, but the wider cascade impacts to infrastructure systems and the longer term impacts on the economy and society. However, understanding the “what if” is only the first part of the equation; a range of improvement measures to mitigate such effects need to be identified and implemented. These measures should consider reducing the risk, lessening the consequences, aiding the response, and speeding up the recovery. However, they need to be objectively assessed through quantitative analysis, which underpins them technically and economically. Without such analysis, it cannot be predicted how measures will perform if the extreme events occur. It is also vital to consider all possible hazards as measures for one hazard may hinder the response to another. The Holistic Integrity Test (HIT, uses quantitative system analysis and “HITs” the site, its infrastructure, contained dangers and wider regional system to determine how it copes with a range of severe shock events, Before, During and After the event, whilst also accounting for uncertainty (as illustrated in figure 1. First explained at the TINCE 2014 Nuclear Conference in Paris, it was explained in terms of a Nuclear Facility needing to analyse the site in response to post Fukushima needs; the hit is however universally applicable. The HIT has three key risk reduction goals: The

  20. Anticipating mismatches of HIT investments: Developing a viability-fit model for e-health services.

    Science.gov (United States)

    Mettler, Tobias

    2016-01-01

    Albeit massive investments in the recent years, the impact of health information technology (HIT) has been controversial and strongly disputed by both research and practice. While many studies are concerned with the development of new or the refinement of existing measurement models for assessing the impact of HIT adoption (ex post), this study presents an initial attempt to better understand the factors affecting viability and fit of HIT and thereby underscores the importance of also having instruments for managing expectations (ex ante). We extend prior research by undertaking a more granular investigation into the theoretical assumptions of viability and fit constructs. In doing so, we use a mixed-methods approach, conducting qualitative focus group discussions and a quantitative field study to improve and validate a viability-fit measurement instrument. Our findings suggest two issues for research and practice. First, the results indicate that different stakeholders perceive HIT viability and fit of the same e-health services very unequally. Second, the analysis also demonstrates that there can be a great discrepancy between the organizational viability and individual fit of a particular e-health service. The findings of this study have a number of important implications such as for health policy making, HIT portfolios, and stakeholder communication. Copyright © 2015. Published by Elsevier Ireland Ltd.

  1. Reionization and Cosmic Dawn: theory and simulations

    Science.gov (United States)

    Mesinger, Andrei

    2018-05-01

    We highlight recent progress in the sophistication and diversification of the simulations of cosmic dawn and reionization. The application of these modeling tools to recent observations has allowed us narrow down the timing of reionization. The midpoint of reionization is constrained to z = 7.6-0.7+0.8 (1 σ), with the strongest constraints coming from the optical depth to the CMB measured with the Planck satellite and the first detection of ongoing reionization from the spectra of the z = 7.1 QSOs ULASJ1120+0641. However, we still know virtually nothing about the astrophysical sources during the first billion years. The revolution in our understanding will be led by upcoming interferometric observations of the cosmic 21-cm signal. The properties of the sources and sinks of UV and X-ray photons are encoded in the 3D patterns of the signal. The development of Bayesian parameter recovery techniques, which tap into the wealth of the 21-cm signal, will soon usher in an era of precision astrophysical cosmology.

  2. Factors associated to the career choice of family medicine among Japanese physicians: the dawn of a new era.

    Science.gov (United States)

    Ie, Kenya; Tahara, Masao; Murata, Akiko; Komiyama, Manabu; Onishi, Hirotaka

    2014-01-01

    Despite recent developments in post-graduate family medicine training in Japan, the numbers of junior doctors entering family medicine residencies are still limited. The objective of this qualitative study was to investigate the possible factors associated to the career choice of family medicine, especially in the context of the newly established family medicine programs in Japan. From December 2010 to January 2011, we distributed a semi-structured questionnaire about career choice to 58 physician members of the Japan Primary Care Association, and 41 of them responded. Four researchers used the Modified Grounded Theory Approach (Kinoshita, 2003) for three-stage conceptualization. We extracted a conceptual model of the choice of newly established family medicine as a career in Japan, consisting of six categories and 77 subordinate concepts from 330 variations. The subcategories of personal background affecting the family-medicine career choice were characteristics ("self-reliance," "pioneering spirit"), career direction ("community/rural-orientedness," "multifaceted orientation") and experience (e.g., "discomfort with fragmented care"). We divided the influencing factors that were identified for career choice into supporters (e.g., "role model"), conflict of career choice (e.g., "anxiety about diverse/broad practice"), and the dawn of a new era in family medicine in Japan (e.g., "lack of social recognition," "concern about livelihood," and "too few role models"). Although the dawn of a new era seemed a rather negative influencer, it was unique to our study that the dawn itself could attract those with a "pioneering spirit" and an "attitude of self-training." Unlike previous studies, the positive factors such as lifestyle and the short residency program were not shown to be part of family medicine's attractiveness. In contrast, "concern about livelihood" was specific among our respondents and was related to career choice in the dawn period. "Community

  3. Calibration

    International Nuclear Information System (INIS)

    Greacen, E.L.; Correll, R.L.; Cunningham, R.B.; Johns, G.G.; Nicolls, K.D.

    1981-01-01

    Procedures common to different methods of calibration of neutron moisture meters are outlined and laboratory and field calibration methods compared. Gross errors which arise from faulty calibration techniques are described. The count rate can be affected by the dry bulk density of the soil, the volumetric content of constitutional hydrogen and other chemical components of the soil and soil solution. Calibration is further complicated by the fact that the neutron meter responds more strongly to the soil properties close to the detector and source. The differences in slope of calibration curves for different soils can be as much as 40%

  4. The prognosis of MYC translocation positive diffuse large B-cell lymphoma depends on the second hit.

    Science.gov (United States)

    Clipson, Alexandra; Barrans, Sharon; Zeng, Naiyan; Crouch, Simon; Grigoropoulos, Nicholas F; Liu, Hongxiang; Kocialkowski, Sylvia; Wang, Ming; Huang, Yuanxue; Worrillow, Lisa; Goodlad, John; Buxton, Jenny; Neat, Michael; Fields, Paul; Wilkins, Bridget; Grant, John W; Wright, Penny; Ei-Daly, Hesham; Follows, George A; Roman, Eve; Watkins, A James; Johnson, Peter W M; Jack, Andrew; Du, Ming-Qing

    2015-07-01

    A proportion of MYC translocation positive diffuse large B-cell lymphomas (DLBCL) harbour a BCL2 and/or BCL6 translocation, known as double-hit DLBCL, and are clinically aggressive. It is unknown whether there are other genetic abnormalities that cooperate with MYC translocation and form double-hit DLBCL, and whether there is a difference in clinical outcome between the double-hit DLBCL and those with an isolated MYC translocation. We investigated TP53 gene mutations along with BCL2 and BCL6 translocations in a total of 234 cases of DLBCL, including 81 with MYC translocation. TP53 mutations were investigated by PCR and sequencing, while BCL2 and BCL6 translocation was studied by interphase fluorescence in situ hybridization. The majority of MYC translocation positive DLBCLs (60/81 = 74%) had at least one additional genetic hit. In MYC translocation positive DLBCL treated by R-CHOP ( n  = 67), TP53 mutation and BCL2, but not BCL6 translocation had an adverse effect on patient overall survival. In comparison with DLBCL with an isolated MYC translocation, cases with MYC/TP53 double-hits had the worst overall survival, followed by those with MYC/BCL2 double-hits. In MYC translocation negative DLBCL treated by R-CHOP ( n  = 101), TP53 mutation, BCL2 and BCL6 translocation had no impact on patient survival. The prognosis of MYC translocation positive DLBCL critically depends on the second hit, with TP53 mutations and BCL2 translocation contributing to an adverse prognosis. It is pivotal to investigate both TP53 mutations and BCL2 translocations in MYC translocation positive DLBCL, and to distinguish double-hit DLBCLs from those with an isolated MYC translocation.

  5. The Metaphor of the Dawn of the Space Age in the Contemporary Social Sciences and Humanities

    Directory of Open Access Journals (Sweden)

    Natalija Majsova

    2015-05-01

    Full Text Available The dawn of the space age in the early 1960s first provoked unabashed awe. Then, it inspired numerous attempts to explain (away the evental status of the first examples of manned spaceflight accounts that mainly interpreted Yuri Garagin’s flight (1961 and the Moon landing (1969 as logical consequences of technological progress, a certain constellation of political circumstances, and a pinch of ‘imagination’ to begin with. Curiously enough, conclusions of the vast majority of such accounts cannot but resort to ‘terrestrial’ metaphors in order to explain why these endeavours were worth undertaking in the first place. In the 21st century, reflections on outer space seem to have settled within three conceptually designed research fields within the social sciences and humanities: astrosociology, noocosmology and cultural studies of outer space. The text analyses conceptualisations and accounts of the dawn of the space age exhibited by the core texts and methodologies of these research fields to demonstrate how they actually hinge on variant epistemologies, and interpret the role of metaphor in world-formation in radically differing ways.

  6. Direct determination of the hit locations from experimental HPGe pulses

    Energy Technology Data Exchange (ETDEWEB)

    Désesquelles, P., E-mail: Pierre.Desesquelles@in2p3.fr [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Dimmock, M.R. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Ljungvall, J. [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Nelson, L. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Nga, D.-T. [Univ. Paris-Sud, CSNSM CNRS/IN2P3, 15 rue G. Clémenceau, 91405 Orsay (France); Nolan, P.J.; Rigby, S.V. [Oliver Lodge Laboratory, The University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Van-Oanh, N.-T. [Univ. Paris-Sud, LCP UMR8000 CNRS, 15 rue G. Clémenceau, 91405 Orsay (France)

    2013-11-21

    The gamma-tracking technique optimises the determination of the energy and emission angle of gamma-rays detected by modern segmented HPGe detectors. This entails the determination, using the delivered pulse shapes, of the interaction points of the gamma-ray within the crystal. The direct method presented here allows the localisation of the hits using only a large sample of pulses detected in the actual operating conditions. No external crystal scanning system or pulse shape simulation code is needed. In order to validate this method, it is applied to sets of pulses obtained using the University of Liverpool scanning system. The hit locations are determined by the method with good precision.

  7. Plasma response to sustainment with imposed-dynamo current drive in HIT-SI and HIT-SI3

    Science.gov (United States)

    Hossack, A. C.; Jarboe, T. R.; Chandra, R. N.; Morgan, K. D.; Sutherland, D. A.; Penna, J. M.; Everson, C. J.; Nelson, B. A.

    2017-07-01

    The helicity injected torus—steady inductive (HIT-SI) program studies efficient, steady-state current drive for magnetic confinement plasmas using a novel experimental method. Stable, high-beta spheromaks have been sustained using steady, inductive current drive. Externally induced loop voltage and magnetic flux are oscillated together so that helicity and power injection are always positive, sustaining the edge plasma current indefinitely. Imposed-dynamo current drive (IDCD) theory further shows that the entire plasma current is sustained. The method is ideal for low aspect ratio, toroidal geometries with closed flux surfaces. Experimental studies of spheromak plasmas sustained with IDCD have shown stable magnetic profiles with evidence of pressure confinement. New measurements show coherent motion of a stable spheromak in response to the imposed perturbations. On the original device two helicity injectors were mounted on either side of the spheromak and the injected mode spectrum was predominantly n  =  1. Coherent, rigid motion indicates that the spheromak is stable and a lack of plasma-generated n  =  1 energy indicates that the maximum q is maintained below 1 during sustainment. Results from the HIT-SI3 device are also presented. Three inductive helicity injectors are mounted on one side of the spheromak flux conserver. Varying the relative injector phasing changes the injected mode spectrum which includes n  =  2, 3, and higher modes.

  8. Vesta in the Light of Dawn: A Nuanced Confirmation of Expectations

    Science.gov (United States)

    Russell, C. T.

    The ion-engine propelled Discovery-class mission Dawn was launched on its near decade-long odyssey to explore the two most massive asteroids in the main belt, 4 Vesta and 1 Ceres, in September 2007. Based on its mass and volume, its basaltic crust, and the chemistry of the associated HED meteorites, Vesta was expected to consist of a completely differentiated dry silicate body with an iron core in contrast to Ceres, whose much smaller density implied a much wetter body, perhaps with liquid water beneath the crust. Upon entering vestan orbit in July 2001, Dawn discovered that indeed the surface resembled the HED meteorites and the gravity data were consistent with a differentiated body with a 110-km radius core. The large southern basin seen from HST was studied and found to consist of two ancient impact basins with associated planetary rings of graben-like fossae. The water that had been hinted at in reflectance spectra observed by terrestrial telescopes was seen more broadly over the surface as was hydrogen detected with the GRaND gamma ray and neutron spectrometer. Moreover, some craters showed evidence for both running and standing water: gullies in the crater walls and pits in the crater floors. Furthermore, the expected exposure of olivine in the southern basin was not found. The presence of water, even if only transient, on the surface of Vesta, and the apparent lack of an olivine mantle were unexpected results. While these observations do not negate the earlier work based on the HED meteorites, they do add important new insight into the conditions under which Vesta formed and evolved.

  9. Isolated orbital mass as the primary presentation of a triple-hit lymphoma transformed from a systemic follicular lymphoma

    Directory of Open Access Journals (Sweden)

    Xiao Yi Zhou

    2018-06-01

    Full Text Available Purpose: Triple-hit lymphoma is a highly aggressive B-cell lymphoma. We report a case of triple-hit lymphoma transformed from systemic follicular lymphoma (FL after 9-year remission and presented primarily as an isolated orbital mass without systemic symptoms or lymphadenopathy. Observations: A 58-year-old female presented with intermittent vertical binocular diplopia, left upper eyelid swelling and pain and was found to have a 2.9 cm orbital mass. Histological section revealed a CD10-positive large B-cell lymphoma, consistent with transformation of FL. Fluorescent in situ hybridization (FISH analysis demonstrated rearrangements involving C-MYC, BCL-2 and BCL-6 genes, indicating a high grade, triple-hit lymphoma. Conclusions and importance: Triple-hit lymphoma transformed from a low-grade lymphoma may initially present as an isolated orbital mass without systemic evidence of transformation. Early recognition of double or triple-hit lymphomas is important since these patients require aggressive chemotherapy. Keywords: Lymphoma, Triple-hit lymphoma, Orbital mass

  10. Lower bounds on the periodic Hamming correlations of frequency hopping sequences with low hit zone

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    In this paper, several periodic Hamming correlation lower bounds for frequency hopping sequences with low hit zone, with respect to the size p of the frequency slot set, the sequence length L, the family size M, low hit zone LH ( or no hit zone NH ), the maximum periodic Hamming autocorrelation sidelobe Ha and the maximum periodic Hamming crosscorrelation Hc, are established. It is shown that the new bounds include the known Lempel-Greenberger bounds, T.S. Seay bounds and Peng-Fan bounds for the conventional frequency hopping sequences as special cases.

  11. 75 FR 6398 - Office of the National Coordinator for Health Information Technology; HIT Policy Committee's...

    Science.gov (United States)

    2010-02-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Office of the National Coordinator for Health Information Technology; HIT Policy Committee's Adoption/Certification Workgroup Meeting; Notice of Meeting AGENCY: Office... of Committee: HIT Policy Committee's Adoption/Certification Workgroup. General Function of the...

  12. Do repeated rumble strip hits improve driver alertness?

    NARCIS (Netherlands)

    Watling, C.N.; Akerstedt, T.; Kecklund, L.G.; Anund, A.

    2016-01-01

    Driving while sleepy is associated with increased crash risk. Rumble strips are designed to alert a sleepy or inattentive driver when they deviate outside their driving lane. The current study sought to examine the effects of repeated rumble strip hits on levels of physiological and subjective

  13. Screening and hit evaluation of a chemical library against blood-stage Plasmodium falciparum.

    Science.gov (United States)

    Avery, Vicky M; Bashyam, Sridevi; Burrows, Jeremy N; Duffy, Sandra; Papadatos, George; Puthukkuti, Shyni; Sambandan, Yuvaraj; Singh, Shivendra; Spangenberg, Thomas; Waterson, David; Willis, Paul

    2014-05-27

    In view of the need to continuously feed the pipeline with new anti-malarial agents adapted to differentiated and more stringent target product profiles (e.g., new modes of action, transmission-blocking activity or long-duration chemo-protection), a chemical library consisting of more than 250,000 compounds has been evaluated in a blood-stage Plasmodium falciparum growth inhibition assay and further assessed for chemical diversity and novelty. The selection cascade used for the triaging of hits from the chemical library started with a robust three-step in vitro assay followed by an in silico analysis of the resulting confirmed hits. Upon reaching the predefined requirements for selectivity and potency, the set of hits was subjected to computational analysis to assess chemical properties and diversity. Furthermore, known marketed anti-malarial drugs were co-clustered acting as 'signposts' in the chemical space defined by the hits. Then, in cerebro evaluation of the chemical structures was performed to identify scaffolds that currently are or have been the focus of anti-malarial medicinal chemistry programmes. Next, prioritization according to relaxed physicochemical parameters took place, along with the search for structural analogues. Ultimately, synthesis of novel chemotypes with desired properties was performed and the resulting compounds were subsequently retested in a P. falciparum growth inhibition assay. This screening campaign led to a 1.25% primary hit rate, which decreased to 0.77% upon confirmatory repeat screening. With the predefined potency (EC₅₀  10) criteria, 178 compounds progressed to the next steps where chemical diversity, physicochemical properties and novelty assessment were taken into account. This resulted in the selection of 15 distinct chemical series. A selection cascade was applied to prioritize hits resulting from the screening of a medium-sized chemical library against blood-stage P. falciparum. Emphasis was placed on chemical

  14. Rumbles and Grumbles from Around the World

    Directory of Open Access Journals (Sweden)

    2000-01-01

    Full Text Available A different kind of shake-up will hit the science establishment when the New Year dawns in earthquake-prone Japan, reports Nature in its lead story this week. Science kicks off self-referentially with a lead story about its decision to publish a paper on sequencing the human genome from Craig Venter of Celera Genomics.

  15. Hit size effectiveness in relation to the microdosimetric site size

    International Nuclear Information System (INIS)

    Varma, M.N.; Wuu, C.S.; Zaider, M.

    1994-01-01

    This paper examines the effect of site size (that is, the diameter of the microdosimetric volume) on the hit size effectiveness function (HSEF), q(y), for several endpoints relevant in radiation protection. A Bayesian and maximum entropy approach is used to solve the integral equations that determine, given microdosimetric spectra and measured initial slopes, the function q(y). All microdosimetric spectra have been calculated de novo. The somewhat surprising conclusion of this analysis is that site size plays only a minor role in selecting the hit size effectiveness function q(y). It thus appears that practical means (e.g. conventional proportional counters) are already at hand to actually implement the HSEF as a radiation protection tool. (Author)

  16. Analysis of variation in calibration curves for Kodak XV radiographic film using model-based parameters.

    Science.gov (United States)

    Hsu, Shu-Hui; Kulasekere, Ravi; Roberson, Peter L

    2010-08-05

    Film calibration is time-consuming work when dose accuracy is essential while working in a range of photon scatter environments. This study uses the single-target single-hit model of film response to fit the calibration curves as a function of calibration method, processor condition, field size and depth. Kodak XV film was irradiated perpendicular to the beam axis in a solid water phantom. Standard calibration films (one dose point per film) were irradiated at 90 cm source-to-surface distance (SSD) for various doses (16-128 cGy), depths (0.2, 0.5, 1.5, 5, 10 cm) and field sizes (5 × 5, 10 × 10 and 20 × 20 cm²). The 8-field calibration method (eight dose points per film) was used as a reference for each experiment, taken at 95 cm SSD and 5 cm depth. The delivered doses were measured using an Attix parallel plate chamber for improved accuracy of dose estimation in the buildup region. Three fitting methods with one to three dose points per calibration curve were investigated for the field sizes of 5 × 5, 10 × 10 and 20 × 20 cm². The inter-day variation of model parameters (background, saturation and slope) were 1.8%, 5.7%, and 7.7% (1 σ) using the 8-field method. The saturation parameter ratio of standard to 8-field curves was 1.083 ± 0.005. The slope parameter ratio of standard to 8-field curves ranged from 0.99 to 1.05, depending on field size and depth. The slope parameter ratio decreases with increasing depth below 0.5 cm for the three field sizes. It increases with increasing depths above 0.5 cm. A calibration curve with one to three dose points fitted with the model is possible with 2% accuracy in film dosimetry for various irradiation conditions. The proposed fitting methods may reduce workload while providing energy dependence correction in radiographic film dosimetry. This study is limited to radiographic XV film with a Lumisys scanner.

  17. The Rock that Hit New York

    Energy Technology Data Exchange (ETDEWEB)

    Meade, Roger Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Keksis, August Lawrence [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-03

    On January 12, 1975, a rock seemed to fall from the sky over New York State’s Schoharie County hitting the tractor of a local farmer, who was “preparing his fields for spring planting.” As the farmer later described the event to a reporter from the UFO INVESTIGATOR, the object glanced off the tractor, fell to the ground, and melted its way through a patch of ice that was two and one half inches thick. The farmer, Leonard Tillapaugh, called the county sheriff, Harvey Stoddard, who recovered the rock, noting that it “was still warm.” Why and how a sample of the rock came to Los Alamos is not known. However, it captivated a wide Laboratory audience, was subjected to rigorous testing and evaluation. Los Alamos used the scientific method in the manner promoted by Hynek. Did Los Alamos solve the mystery of the rock’s origin? Not definitively. Although the exact origin could not be determined, it was shown conclusively that the rock was not from outer space. With that said, the saga of Rock that hit New York came to an end. Nothing more was said or written about it. The principals involved have long since passed from the scene. The NICAP ceased operations in 1980. And, the rock, itself, has disappeared.

  18. Reviewing Hit Discovery Literature for Difficult Targets: Glutathione Transferase Omega-1 as an Example.

    Science.gov (United States)

    Xie, Yiyue; Dahlin, Jayme L; Oakley, Aaron J; Casarotto, Marco G; Board, Philip G; Baell, Jonathan B

    2018-05-10

    Early stage drug discovery reporting on relatively new or difficult targets is often associated with insufficient hit triage. Literature reviews of such targets seldom delve into the detail required to critically analyze the associated screening hits reported. Here we take the enzyme glutathione transferase omega-1 (GSTO1-1) as an example of a relatively difficult target and review the associated literature involving small-molecule inhibitors. As part of this process we deliberately pay closer-than-usual attention to assay interference and hit quality aspects. We believe this Perspective will be a useful guide for future development of GSTO1-1 inhibitors, as well serving as a template for future review formats of new or difficult targets.

  19. Synthetic Medicinal Chemistry in Chagas' Disease: Compounds at The Final Stage of "Hit-To-Lead" Phase.

    Science.gov (United States)

    Cerecetto, Hugo; González, Mercedes

    2010-03-25

    Chagas' disease, or American trypanosomosiasis, has been the most relevant illness produced by protozoa in Latin America. Synthetic medicinal chemistry efforts have provided an extensive number of chemodiverse hits at the "active-to-hit" stage. However, only a more limited number of these have been studied in vivo in models of Chagas' disease. Herein, we survey some of the cantidates able to surpass the "hit-to-lead" stage discussing their limitations or merit to enter in clinical trials in the short term.

  20. 76 FR 1432 - Office of the National Coordinator for Health Information Technology; HIT Standards Committee...

    Science.gov (United States)

    2011-01-10

    ... Technology; HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of Meeting. This notice announces a... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards...

  1. 75 FR 8954 - Office of the National Coordinator for Health Information Technology; HIT Standards Committee...

    Science.gov (United States)

    2010-02-26

    ... Technology; HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS ACTION: Notice of meeting. This notice announces a... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards...

  2. 75 FR 70923 - Office of the National Coordinator for Health Information Technology; HIT Policy Committee...

    Science.gov (United States)

    2010-11-19

    ... Technology; HIT Policy Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS ACTION: Notice of meeting. This notice announces a... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Policy Committee...

  3. 75 FR 70923 - Office of the National Coordinator for Health Information Technology; HIT Standards Committee...

    Science.gov (United States)

    2010-11-19

    ... Technology; HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of meeting. This notice announces a... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards...

  4. 75 FR 29761 - Office of the National Coordinator for Health Information Technology: HIT Standards Committee...

    Science.gov (United States)

    2010-05-27

    ... Technology: HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of meeting. This notice announces a... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards...

  5. 76 FR 4354 - Office of the National Coordinator for Health Information Technology; HIT Standards Committee...

    Science.gov (United States)

    2011-01-25

    ... Technology; HIT Standards Committee Advisory Meeting; Notice of Meeting AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice of meeting. This notice announces a... Information Technology (ONC). The meeting will be open to the public. Name of Committee: HIT Standards...

  6. Comparison of Video Head Impulse Test (vHIT) Gains Between Two Commercially Available Devices and by Different Gain Analytical Methods.

    Science.gov (United States)

    Lee, Sang Hun; Yoo, Myung Hoon; Park, Jun Woo; Kang, Byung Chul; Yang, Chan Joo; Kang, Woo Suk; Ahn, Joong Ho; Chung, Jong Woo; Park, Hong Ju

    2018-06-01

    To evaluate whether video head impulse test (vHIT) gains are dependent on the measuring device and method of analysis. Prospective study. vHIT was performed in 25 healthy subjects using two devices simultaneously. vHIT gains were compared between these instruments and using five different methods of comparing position and velocity gains during head movement intervals. The two devices produced different vHIT gain results with the same method of analysis. There were also significant differences in the vHIT gains measured using different analytical methods. The gain analytic method that compares the areas under the velocity curve (AUC) of the head and eye movements during head movements showed lower vHIT gains than a method that compared the peak velocities of the head and eye movements. The former method produced the vHIT gain with the smallest standard deviation among the five procedures tested in this study. vHIT gains differ in normal subjects depending on the device and method of analysis used, suggesting that it is advisable for each device to have its own normal values. Gain calculations that compare the AUC of the head and eye movements during the head movements show the smallest variance.

  7. Role of Health Information Technology (HIT) in disability determinations: when medical records become medical evidence.

    Science.gov (United States)

    Tulu, Bengisu; Daniels, Susan; Feldman, Sue; Horan, Thomas A

    2008-11-06

    This exploratory study investigated the impact of incomplete medical evidence on the SSA disability determination process and the role of HIT as a solution. We collected qualitative data from nineteen expert-interviews. Findings indicate that HIT can lead to innovative solutions that can significantly improve the determination process.

  8. Influence of The Difference of Perception and Kinesthetic Exercise Methods Against Precision Hit The Ball Softball

    Directory of Open Access Journals (Sweden)

    Fajar Rokhayah

    2017-06-01

    Full Text Available The purpose of this study was to determine: 1 The difference between the effects of training methods and the gradual striking distance striking distance remains as to the accuracy of hitting the ball Softball. 2 The difference in accuracy influence Softball hitting the ball between the athletes who have a good kinesthetic perception, kinesthetic perception was, and kinesthetic perception less. 3 The effect of interaction between training methods with kinesthetic perception as to the accuracy of hitting the ball Softball. This study used an experimental method with 2x3 factorial design. The results of this study were: 1 There is a significant difference between the gradual striking distance training methods and training methods remain striking distance of the ability to hit a softball with the result of the acquisition value p-value = 0.027 smaller than 0.05. 2 There is a significant difference between athletes who have a kinesthetic perception of good, moderate, lacking the ability to hit a softball with the result of the acquisition value p-value = 0.000, which is smaller than 0.05. 3 There is an interaction between striking distance training methods and kinesthetic perception of the ability to hit a softball with the result of the acquisition value p-value = 0.000, which is smaller than 0.05 The conclusion of this study were: 1 Gradually striking distance training methods have a better effect than the fixed striking distance training methods. 2 Athletes who have less kinesthetic perception has better results than the athletes who have good kinesthetic perception and being. 3 There is an interaction between striking distance training methods and kinesthetic perception of the ability to hit a softball.

  9. Isolated orbital mass as the primary presentation of a triple-hit lymphoma transformed from a systemic follicular lymphoma.

    Science.gov (United States)

    Zhou, Xiao Yi; Lu, Xinyan; Raparia, Kirtee; Chen, Yi-Hua

    2018-06-01

    Triple-hit lymphoma is a highly aggressive B-cell lymphoma. We report a case of triple-hit lymphoma transformed from systemic follicular lymphoma (FL) after 9-year remission and presented primarily as an isolated orbital mass without systemic symptoms or lymphadenopathy. A 58-year-old female presented with intermittent vertical binocular diplopia, left upper eyelid swelling and pain and was found to have a 2.9 cm orbital mass. Histological section revealed a CD10-positive large B-cell lymphoma, consistent with transformation of FL. Fluorescent in situ hybridization (FISH) analysis demonstrated rearrangements involving C-MYC, BCL-2 and BCL-6 genes, indicating a high grade, triple-hit lymphoma. Triple-hit lymphoma transformed from a low-grade lymphoma may initially present as an isolated orbital mass without systemic evidence of transformation. Early recognition of double or triple-hit lymphomas is important since these patients require aggressive chemotherapy.

  10. Chronic Porcine Two-Hit Model with Hemorrhagic Shock and textitPseudomonas aeruginosa Sepsis

    OpenAIRE

    Eissner, B.;Matz, K.;Smorodchenko, A.;Röschmann, A.;Specht, B. U. v.

    2016-01-01

    Background: Sepsis is still a major cause of death despite well-developed therapeutical strategies such as antibiotics and supportive medication. The aim of this study was to characterize the long-term effects of a two-hit porcine sepsis model with a hemorrhagic shock as ‘first hit’ followed by a Pseudomonas aeruginosa infusion as ‘second hit’. Materials and Methods: Twelve juvenile healthy pigs were anesthetized and hemodynamically monitored. The two-hit group (n = 6) underwent a hemorrhagic...

  11. Near-optimal alternative generation using modified hit-and-run sampling for non-linear, non-convex problems

    Science.gov (United States)

    Rosenberg, D. E.; Alafifi, A.

    2016-12-01

    Water resources systems analysis often focuses on finding optimal solutions. Yet an optimal solution is optimal only for the modelled issues and managers often seek near-optimal alternatives that address un-modelled objectives, preferences, limits, uncertainties, and other issues. Early on, Modelling to Generate Alternatives (MGA) formalized near-optimal as the region comprising the original problem constraints plus a new constraint that allowed performance within a specified tolerance of the optimal objective function value. MGA identified a few maximally-different alternatives from the near-optimal region. Subsequent work applied Markov Chain Monte Carlo (MCMC) sampling to generate a larger number of alternatives that span the near-optimal region of linear problems or select portions for non-linear problems. We extend the MCMC Hit-And-Run method to generate alternatives that span the full extent of the near-optimal region for non-linear, non-convex problems. First, start at a feasible hit point within the near-optimal region, then run a random distance in a random direction to a new hit point. Next, repeat until generating the desired number of alternatives. The key step at each iterate is to run a random distance along the line in the specified direction to a new hit point. If linear equity constraints exist, we construct an orthogonal basis and use a null space transformation to confine hits and runs to a lower-dimensional space. Linear inequity constraints define the convex bounds on the line that runs through the current hit point in the specified direction. We then use slice sampling to identify a new hit point along the line within bounds defined by the non-linear inequity constraints. This technique is computationally efficient compared to prior near-optimal alternative generation techniques such MGA, MCMC Metropolis-Hastings, evolutionary, or firefly algorithms because search at each iteration is confined to the hit line, the algorithm can move in one

  12. Markov chains with quasitoeplitz transition matrix: first zero hitting

    Directory of Open Access Journals (Sweden)

    Alexander M. Dukhovny

    1989-01-01

    Full Text Available This paper continues the investigation of Markov Chains with a quasitoeplitz transition matrix. Generating functions of first zero hitting probabilities and mean times are found by the solution of special Riemann boundary value problems on the unit circle. Duality is discussed.

  13. #MaybeHeDoesntHitYou: Social Media Underscore the Realities of Intimate Partner Violence.

    Science.gov (United States)

    McCauley, Heather L; Bonomi, Amy E; Maas, Megan K; Bogen, Katherine W; O'Malley, Teagen L

    2018-03-22

    Public intimate partner violence (IPV) discourse emphasizes physical violence. In May 2016, the Twitter hashtag #MaybeHeDoesntHitYou generated a public conversation about abuse beyond physical IPV. Because of the often-disconnect between IPV research and what survivors struggle to name as abuse in their daily lives, we sought to understand how IPV discourse was unfolding as a result of the #MaybeHeDoesntHitYou hashtag. NCapture was used to collect publically available Twitter data containing the hashtag "#MaybeHeDoesntHitYou" from May 10, 2016 to May 17, 2016. Using the Duluth Power and Control Wheel (a range of tactics used by abusers to control and harm their partners) and the Women's Experience with Battering (WEB) framework (emotional and behavioral responses to being abused), we analyzed 1,229 original content tweets using qualitative content analysis. All dimensions of the Power and Control Wheel and five of six dimensions of the WEB framework were expressed via #MaybeHeDoesntHitYou; users did not express yearning for intimacy with their abusive partners. Users described one form of IPV not currently represented within the Power and Control Wheel-reproductive coercion (e.g., "#MaybeHeDoesntHitYou but he refuses to use condoms and forces you not to use contraception so you try to do it behind his back"). Two additional themes emerged; users challenged the gender pronoun of the hashtag, highlighting that abuse may happen with partners of all genders, and users provided social support for others (e.g., "#MaybeHeDoesntHitYou is real. Bruises and scars aren't the only measure of abuse! If this is you, help is there…"). Results from our study underscore the potential for social media platforms to be powerful agents for engaging public dialogue about the realities of IPV, as well as a space for seeking and providing social support about this critical women's health issue.

  14. Emergency Department Visits Involving Misuse and Abuse of the Antipsychotic Quetiapine: Results from the Drug Abuse Warning Network (DAWN

    Directory of Open Access Journals (Sweden)

    Margaret E. Mattson

    2015-01-01

    Full Text Available Case reports in medical literature suggest that the atypical antipsychotic quetiapine, a medication not previously considered to have abuse potential, is now being subject to misuse and abuse (MUA; ie, taken when not prescribed for them or used in a way other than instructed by their health professional. Here we present systematic, nationally representative data from the 2005 to 2011 Drug Abuse Warning Network (DAWN for prevalence of emergency department (ED visits among the U.S. general population involving quetiapine and related to MUA, suicide attempts, and adverse reactions. Nationally, quetiapine-related ED visits increased 90% between 2005 and 2011, from 35,581 ED visits to 67,497. DAWN data indicate that when used without medical supervision for recreational/self-medication purposes, quetiapine poses health risks for its users, especially among polydrug users and women. These findings suggest that the medical and public health communities should increase vigilance concerning this drug and its potential for MUA.

  15. Modeling distortion of HIT by an Actuator Disk in a periodic domain

    Science.gov (United States)

    Ghate, Aditya; Ghaisas, Niranjan; Lele, Sanjiva

    2017-11-01

    We study the distortion of incompressible, homogeneous isotropic turbulence (HIT) by a dragging actuator disk with a fixed thrust coefficient (under the large Reynolds number limit), using Large Eddy Simulation (LES). The HIT inflow is tailored to ensure that the largest length scales in the flow are smaller than the actuator disk diameter in order to minimize the meandering of the turbulent wake and isolate the length scales that undergo distortion. The numerical scheme (Fourier collocation with dealiasing) and the SGS closure (anisotropic minimum dissipation model) are carefully selected to minimize numerical artifacts expected due to the inviscid assumption. The LES is used to characterize the following 3 properties of the flow a) distortion of HIT due to the expanding streamtube resulting in strong anisotropy, b) turbulent pressure modulation across the actuator disk, and the c) turbulent wake state. Finally, we attempt to model the initial distortion and the pressure modulation using a WKB variant of RDT solved numerically using a set of discrete Gabor modes. Funding provided by Precourt Institute for Energy at Stanford University.

  16. Hype, Hope, and Hit in Movies

    DEFF Research Database (Denmark)

    Dholakia, Nikhilesh; Turcan, Romeo V.

    2012-01-01

    This paper is part of an ongoing project to develop an interdisciplinary metatheory of bubbles, relevant to the contemporary era of globalization and rapid, technology-aided communication flows. Just in the first few years of the 21st century, several bubbles have appeared – the so-called dotcom ...... cultural field where relatively small bubbles may form. Movies represent a good arena to examine cultural bubbles on a scale that is not daunting, and where the hype-hope-hit dynamics can be observed more frequently than in most other settings....

  17. The three-hit concept of vulnerability and resilience: toward understanding adaptation to early-life adversity outcome.

    Science.gov (United States)

    Daskalakis, Nikolaos P; Bagot, Rosemary C; Parker, Karen J; Vinkers, Christiaan H; de Kloet, E R

    2013-09-01

    Stressful experiences during early-life can modulate the genetic programming of specific brain circuits underlying emotional and cognitive aspects of behavioral adaptation to stressful experiences later in life. Although this programming effect exerted by experience-related factors is an important determinant of mental health, its outcome depends on cognitive inputs and hence the valence an individual assigns to a given environmental context. From this perspective we will highlight, with studies in rodents, non-human primates and humans, the three-hit concept of vulnerability and resilience to stress-related mental disorders, which is based on gene-environment interactions during critical phases of perinatal and juvenile brain development. The three-hit (i.e., hit-1: genetic predisposition, hit-2: early-life environment, and hit-3: later-life environment) concept accommodates the cumulative stress hypothesis stating that in a given context vulnerability is enhanced when failure to cope with adversity accumulates. Alternatively, the concept also points to the individual's predictive adaptive capacity, which underlies the stress inoculation and match/mismatch hypotheses. The latter hypotheses propose that the experience of relatively mild early-life adversity prepares for the future and promotes resilience to similar challenges in later-life; when a mismatch occurs between early and later-life experience, coping is compromised and vulnerability is enhanced. The three-hit concept is fundamental for understanding how individuals can either be prepared for coping with life to come and remain resilient or are unable to do so and succumb to a stress-related mental disorder, under seemingly identical circumstances. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Dual hit lipopolysaccharide & oleic acid combination induced rat model of acute lung injury/acute respiratory distress syndrome.

    Science.gov (United States)

    Hagawane, T N; Gaikwad, R V; Kshirsagar, N A

    2016-05-01

    Despite advances in therapy and overall medical care, acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) management remains a problem. Hence the objective of this study was to develop a rat model that mimics human ALI/ARDS. Four groups of Wistar rats, 48 per group were treated with (i) intratracheal (IT) lipopolysaccharide (LPS) (5 mg/kg) dissolved in normal saline (NS), (ii) intravenous (iv) oleic acid (OA) (250 μl/kg) suspension in bovine serum albumin (BSA), (iii) dual hit: IT LPS (2 mg/kg) dissolved in NS and iv OA (100 μl/kg) and (iv) control group: IT NS and iv BSA. From each group at set periods of time various investigations like chest x-rays, respiratory rate (RR), tidal volume (TV), total cell count, differential cell count, total protein count and cytokine levels in bronchoalveolar lavage fluid (BALF), lung wet/dry weight ratio and histopathological examination were done. It was noted that the respiratory rate, and tumour necrosis factor-α (TNF-α) levels were significantly higher at 4 h in the dual hit group as compared to LPS, OA and control groups. Interleukin-6 (IL-6) levels were significantly higher in the dual hit group as compared to LPS at 8 and 24 h, OA at 8 h and control (at all time intervals) group. IL-1β levels were significantly higher in LPS and dual hit groups at all time intervals, but not in OA and control groups. The injury induced in dual hit group was earlier and more sustained as compared to LPS and OA alone. The lung pathology and changes in respiration functions produced by the dual hit model were closer to the diagnostic criteria of ALI/ARDS in terms of clinical manifestations and pulmonary injury and the injury persisted longer as compared to LPS and OA single hit model. Therefore, the ARDS model produced by the dual hit method was closer to the diagnostic criteria of ARDS in terms of clinical manifestations and pulmonary injury.

  19. DEPDC5 takes a second hit in familial focal epilepsy.

    Science.gov (United States)

    Anderson, Matthew P

    2018-04-30

    Loss-of-function mutations in a single allele of the gene encoding DEP domain-containing 5 protein (DEPDC5) are commonly linked to familial focal epilepsy with variable foci; however, a subset of patients presents with focal cortical dysplasia that is proposed to result from a second-hit somatic mutation. In this issue of the JCI, Ribierre and colleagues provide several lines of evidence to support second-hit DEPDC5 mutations in this disorder. Moreover, the authors use in vivo, in utero electroporation combined with CRISPR-Cas9 technology to generate a murine model of the disease that recapitulates human manifestations, including cortical dysplasia-like changes, focal seizures, and sudden unexpected death. This study provides important insights into familial focal epilepsy and provides a preclinical model for evaluating potential therapies.

  20. B-HIT - A Tool for Harvesting and Indexing Biodiversity Data.

    Directory of Open Access Journals (Sweden)

    Patricia Kelbert

    Full Text Available With the rapidly growing number of data publishers, the process of harvesting and indexing information to offer advanced search and discovery becomes a critical bottleneck in globally distributed primary biodiversity data infrastructures. The Global Biodiversity Information Facility (GBIF implemented a Harvesting and Indexing Toolkit (HIT, which largely automates data harvesting activities for hundreds of collection and observational data providers. The team of the Botanic Garden and Botanical Museum Berlin-Dahlem has extended this well-established system with a range of additional functions, including improved processing of multiple taxon identifications, the ability to represent associations between specimen and observation units, new data quality control and new reporting capabilities. The open source software B-HIT can be freely installed and used for setting up thematic networks serving the demands of particular user groups.

  1. Powered two-wheeler drivers' risk of hitting a pedestrian in towns.

    Science.gov (United States)

    Clabaux, Nicolas; Fournier, Jean-Yves; Michel, Jean-Emmanuel

    2014-12-01

    The risk of collision between pedestrians and powered two-wheelers is poorly understood today. The objective of this research is to determine the risk for powered two-wheeler drivers of hitting and injuring a pedestrian per kilometer driven in towns and to compare this risk with that run by four-wheeled vehicle drivers. Using the bodily injury accidents recorded by the police on nine roads in the city of Marseille in 2011 and a campaign of observations of powered two-wheeler traffic, we estimated the risk per kilometer driven by powered two-wheeler drivers of hitting a pedestrian and compared it with the risk run by four-wheeled vehicle drivers. The results show that the risk for powered two-wheeler drivers of hitting and injuring a pedestrian is significantly higher than the risk run by four-wheeled vehicle drivers. On the nine roads studied, it is on average 3.33 times higher (95% CI: 1.63; 6.78). Taking four more years into account made it possible to consolidate these results and to tighten the confidence interval. There does indeed seem to be problems in the interactions between pedestrians and powered two-wheeler users in urban traffic. These interaction problems lead to a higher risk of hitting and injuring a pedestrian for powered two-wheeler drivers than for four-wheeled vehicle drivers. The analysis of the police reports suggests that part of this increased risk comes from filtering maneuvers by powered two-wheelers. Possible countermeasures deal with the urban street layout. Measures consisting in reducing the width and the number of traffic lanes to a strict minimum and installing medians or pedestrian islands could be an effective way for the prevention of urban accidents between pedestrians and powered two-wheelers. Copyright © 2014 National Safety Council and Elsevier Ltd. All rights reserved.

  2. Analysis of impact noise induced by hitting of titanium head golf driver.

    Science.gov (United States)

    Kim, Young Ho; Kim, Young Chul; Lee, Jun Hee; An, Yong-Hwi; Park, Kyung Tae; Kang, Kyung Min; Kang, Yeon June

    2014-11-01

    The hitting of titanium head golf driver against golf ball creates a short duration, high frequency impact noise. We analyzed the spectra of these impact noises and evaluated the auditory hazards from exposure to the noises. Noises made by 10 titanium head golf drivers with five maximum hits were collected, and the spectra of the pure impact sounds were studied using a noise analysis program. The noise was measured at 1.7 m (position A) and 3.4 m (position B) from the hitting point in front of the hitter and at 3.4 m (position C) behind the hitting point. Average time duration was measured and auditory risk units (ARUs) at position A were calculated using the Auditory Hazard Assessment Algorithm for Humans. The average peak levels at position A were 119.9 dBA at the sound pressure level (SPL) peak and 100.0 dBA at the overall octave level. The average peak levels (SPL and overall octave level) at position B were 111.6 and 96.5 dBA, respectively, and at position C were 111.5 and 96.7 dBA, respectively. The average time duration and ARUs measured at position A were 120.6 ms and 194.9 units, respectively. Although impact noises made by titanium head golf drivers showed relatively low ARUs, individuals enjoying golf frequently may be susceptible to hearing loss due to the repeated exposure of this intense impact noise with short duration and high frequency. Unprotected exposure to impact noises should be limited to prevent cochleovestibular disorders.

  3. First hitting probabilities for semi markov chains and estimation

    DEFF Research Database (Denmark)

    Georgiadis, Stylianos

    2017-01-01

    We first consider a stochastic system described by an absorbing semi-Markov chain with finite state space and we introduce the absorption probability to a class of recurrent states. Afterwards, we study the first hitting probability to a subset of states for an irreducible semi-Markov chain...

  4. An extended study of the low-latitude boundary layer on the dawn and dusk flanks of the magnetosphere

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Kutchko, F.; Williams, D.J.; Eastman, T.E.; Frank, L.A.; Russell, C.T.

    1987-01-01

    The authors present a study of the low-latitude boundary layer (LLBL) using ISEE 1 energetic particle, plasma, and magnetic field data obtained during numerous traversals of the LLBL that occurred on 66 ISEE 1 passes through the magnetospheric flank LLBL region. They use energetic particle distributions to determine dawn and dusk LLBL behavior and topology for varying orientations of the magnetosheath and/or interplanetary magnetic field (M/IMF), for different local times, and for changing levels of geomagnetic activity (Kp). This study corroborates and extends the earlier work of Williams et al. (1985) who presented a detailed study of two (dusk and dawn) ISEE 1 passes through the LLBL region for the case of northward M/IMF. They find that the dawn and dusk LLBL are on closed geomagnetic field lines for northward M/IMF but are on a combination of closed and open field lines for a southward M/IMF. The energetic particle distributions show that cases of reverse-draped field lines in the LLBL are consistent with an open field line topology. In addition, they find that the LLBL is thicker (thinner) for northward (southward) M/IMF and becomes thicker with increasing distance from the subsolar point. LLBL electric fields nominally are in the few (3-5) millivolts per meter range and display an apparent maximum value of ∼10mV/m. These electric fields capture magnetospherically drifting particles as they approach the LLBL and propel them tailward. In this way, the plasma sheet is the dominant source of energetic (approx-gt 10 keV) particles in the LLBL while the magnetosheath appears to be the dominant source for lower-energy (approx-lt 10 keV) LLBL particles

  5. Promiscuous 2-aminothiazoles (PrATs): a frequent hitting scaffold.

    Science.gov (United States)

    Devine, Shane M; Mulcair, Mark D; Debono, Cael O; Leung, Eleanor W W; Nissink, J Willem M; Lim, San Sui; Chandrashekaran, Indu R; Vazirani, Mansha; Mohanty, Biswaranjan; Simpson, Jamie S; Baell, Jonathan B; Scammells, Peter J; Norton, Raymond S; Scanlon, Martin J

    2015-02-12

    We have identified a class of molecules, known as 2-aminothiazoles (2-ATs), as frequent-hitting fragments in biophysical binding assays. This was exemplified by 4-phenylthiazol-2-amine being identified as a hit in 14/14 screens against a diverse range of protein targets, suggesting that this scaffold is a poor starting point for fragment-based drug discovery. This prompted us to analyze this scaffold in the context of an academic fragment library used for fragment-based drug discovery (FBDD) and two larger compound libraries used for high-throughput screening (HTS). This analysis revealed that such "promiscuous 2-aminothiazoles" (PrATs) behaved as frequent hitters under both FBDD and HTS settings, although the problem was more pronounced in the fragment-based studies. As 2-ATs are present in known drugs, they cannot necessarily be deemed undesirable, but the combination of their promiscuity and difficulties associated with optimizing them into a lead compound makes them, in our opinion, poor scaffolds for fragment libraries.

  6. An explanation of closed-flux formation and sustainment using coaxial helicity injection on HIT-II

    International Nuclear Information System (INIS)

    Jarboe, T R

    2010-01-01

    An explanation of the closed-flux operation on HIT-II is given. This method of operation generated flux amplification and closed flux on HIT-II without the presence of n = 1 or any large amplitude mode as measured from the outside shell. The method of operating also prevents hard absorber arcs and maximizes the toroidal current.

  7. On hitting children: a review of corporal punishment in the United States.

    Science.gov (United States)

    Knox, Michele

    2010-01-01

    Research has clearly demonstrated associations between corporal punishment of children and maladaptive behavior patterns such as aggression and delinquency. Hitting children is an act of violence and a clear violation of children's human rights. In this article, the position of the United States on corporal punishment of children is discussed. Professional and international progress on ending corporal punishment is explained, and the relationship between corporal punishment and child abuse is discussed. An appeal is made for prevention efforts such as parent education and removal of social sanctions for hitting children that may hold significant promise for preventing child maltreatment.

  8. Another look at volume self-calibration: calibration and self-calibration within a pinhole model of Scheimpflug cameras

    International Nuclear Information System (INIS)

    Cornic, Philippe; Le Besnerais, Guy; Champagnat, Frédéric; Illoul, Cédric; Cheminet, Adam; Le Sant, Yves; Leclaire, Benjamin

    2016-01-01

    We address calibration and self-calibration of tomographic PIV experiments within a pinhole model of cameras. A complete and explicit pinhole model of a camera equipped with a 2-tilt angles Scheimpflug adapter is presented. It is then used in a calibration procedure based on a freely moving calibration plate. While the resulting calibrations are accurate enough for Tomo-PIV, we confirm, through a simple experiment, that they are not stable in time, and illustrate how the pinhole framework can be used to provide a quantitative evaluation of geometrical drifts in the setup. We propose an original self-calibration method based on global optimization of the extrinsic parameters of the pinhole model. These methods are successfully applied to the tomographic PIV of an air jet experiment. An unexpected by-product of our work is to show that volume self-calibration induces a change in the world frame coordinates. Provided the calibration drift is small, as generally observed in PIV, the bias on the estimated velocity field is negligible but the absolute location cannot be accurately recovered using standard calibration data. (paper)

  9. Diabetes Attitudes, Wishes and Needs second study (DAWN2™)

    DEFF Research Database (Denmark)

    Nicolucci, Antonio; Kovacs Burns, K; Holt, Richard I G

    2013-01-01

    AIMS: The second Diabetes Attitudes, Wishes and Needs (DAWN2) study aimed to assess psychosocial outcomes in people with diabetes across countries for benchmarking. METHODS: Surveys included new and adapted questions from validated questionnaires that assess health-related quality of life, self......-management, attitudes/beliefs, social support and priorities for improving diabetes care. Questionnaires were conducted online, by telephone or in person. RESULTS: Participants were 8596 adults with diabetes across 17 countries. There were significant between-country differences for all benchmarking indicators; no one...... (17.2-67.6%). Overall quality of life was rated 'poor' or 'very poor' by 12.2% of participants (7.6-26.1%). Diabetes had a negative impact on all aspects investigated, ranging from 20.5% on relationship with family/friends to 62.2% on physical health. Approximately 40% of participants (18...

  10. Sun exposure causes somatic second-hit mutations and angiofibroma development in tuberous sclerosis complex

    Science.gov (United States)

    Tyburczy, Magdalena E.; Wang, Ji-an; Li, Shaowei; Thangapazham, Rajesh; Chekaluk, Yvonne; Moss, Joel; Kwiatkowski, David J.; Darling, Thomas N.

    2014-01-01

    Tuberous sclerosis complex (TSC) is characterized by the formation of tumors in multiple organs and is caused by germline mutation in one of two tumor suppressor genes, TSC1 and TSC2. As for other tumor suppressor gene syndromes, the mechanism of somatic second-hit events in TSC tumors is unknown. We grew fibroblast-like cells from 29 TSC skin tumors from 22 TSC subjects and identified germline and second-hit mutations in TSC1/TSC2 using next-generation sequencing. Eighteen of 22 (82%) subjects had a mutation identified, and 8 of the 18 (44%) subjects were mosaic with mutant allele frequencies of 0 to 19% in normal tissue DNA. Multiple tumors were available from four patients, and in each case, second-hit mutations in TSC2 were distinct indicating they arose independently. Most remarkably, 7 (50%) of the 14 somatic point mutations were CC>TT ultraviolet ‘signature’ mutations, never seen as a TSC germline mutation. These occurred exclusively in facial angiofibroma tumors from sun-exposed sites. These results implicate UV-induced DNA damage as a cause of second-hit mutations and development of TSC facial angiofibromas and suggest that measures to limit UV exposure in TSC children and adults should reduce the frequency and severity of these lesions. PMID:24271014

  11. Cerebellar inactivation impairs memory of learned prism gaze-reach calibrations.

    Science.gov (United States)

    Norris, Scott A; Hathaway, Emily N; Taylor, Jordan A; Thach, W Thomas

    2011-05-01

    Three monkeys performed a visually guided reach-touch task with and without laterally displacing prisms. The prisms offset the normally aligned gaze/reach and subsequent touch. Naive monkeys showed adaptation, such that on repeated prism trials the gaze-reach angle widened and touches hit nearer the target. On the first subsequent no-prism trial the monkeys exhibited an aftereffect, such that the widened gaze-reach angle persisted and touches missed the target in the direction opposite that of initial prism-induced error. After 20-30 days of training, monkeys showed long-term learning and storage of the prism gaze-reach calibration: they switched between prism and no-prism and touched the target on the first trials without adaptation or aftereffect. Injections of lidocaine into posterolateral cerebellar cortex or muscimol or lidocaine into dentate nucleus temporarily inactivated these structures. Immediately after injections into cortex or dentate, reaches were displaced in the direction of prism-displaced gaze, but no-prism reaches were relatively unimpaired. There was little or no adaptation on the day of injection. On days after injection, there was no adaptation and both prism and no-prism reaches were horizontally, and often vertically, displaced. A single permanent lesion (kainic acid) in the lateral dentate nucleus of one monkey immediately impaired only the learned prism gaze-reach calibration and in subsequent days disrupted both learning and performance. This effect persisted for the 18 days of observation, with little or no adaptation.

  12. Calibration uncertainty

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Anglov, Thomas

    2002-01-01

    Methods recommended by the International Standardization Organisation and Eurachem are not satisfactory for the correct estimation of calibration uncertainty. A novel approach is introduced and tested on actual calibration data for the determination of Pb by ICP-AES. The improved calibration...

  13. Computing Principal Eigenvectors of Large Web Graphs: Algorithms and Accelerations Related to PageRank and HITS

    Science.gov (United States)

    Nagasinghe, Iranga

    2010-01-01

    This thesis investigates and develops a few acceleration techniques for the search engine algorithms used in PageRank and HITS computations. PageRank and HITS methods are two highly successful applications of modern Linear Algebra in computer science and engineering. They constitute the essential technologies accounted for the immense growth and…

  14. The average number of alpha-particle hits to the cell nucleus required to eradicate a tumour cell population

    International Nuclear Information System (INIS)

    Roeske, John C; Stinchcomb, Thomas G

    2006-01-01

    Alpha-particle emitters are currently being considered for the treatment of micrometastatic disease. Based on in vitro studies, it has been speculated that only a few alpha-particle hits to the cell nucleus are considered lethal. However, such estimates do not consider the stochastic variations in the number of alpha-particle hits, energy deposited, or in the cell survival process itself. Using a tumour control probability (TCP) model for alpha-particle emitters, we derive an estimate of the average number of hits to the cell nucleus required to provide a high probability of eradicating a tumour cell population. In simulation studies, our results demonstrate that the average number of hits required to achieve a 90% TCP for 10 4 clonogenic cells ranges from 18 to 108. Those cells that have large cell nuclei, high radiosensitivities and alpha-particle emissions occurring primarily in the nuclei tended to require more hits. As the clinical implementation of alpha-particle emitters is considered, this type of analysis may be useful in interpreting clinical results and in designing treatment strategies to achieve a favourable therapeutic outcome. (note)

  15. Development and formative evaluation of the e-Health Implementation Toolkit (e-HIT

    Directory of Open Access Journals (Sweden)

    Mair Frances

    2010-10-01

    Full Text Available Abstract Background The use of Information and Communication Technology (ICT or e-Health is seen as essential for a modern, cost-effective health service. However, there are well documented problems with implementation of e-Health initiatives, despite the existence of a great deal of research into how best to implement e-Health (an example of the gap between research and practice. This paper reports on the development and formative evaluation of an e-Health Implementation Toolkit (e-HIT which aims to summarise and synthesise new and existing research on implementation of e-Health initiatives, and present it to senior managers in a user-friendly format. Results The content of the e-HIT was derived by combining data from a systematic review of reviews of barriers and facilitators to implementation of e-Health initiatives with qualitative data derived from interviews of "implementers", that is people who had been charged with implementing an e-Health initiative. These data were summarised, synthesised and combined with the constructs from the Normalisation Process Model. The software for the toolkit was developed by a commercial company (RocketScience. Formative evaluation was undertaken by obtaining user feedback. There are three components to the toolkit - a section on background and instructions for use aimed at novice users; the toolkit itself; and the report generated by completing the toolkit. It is available to download from http://www.ucl.ac.uk/pcph/research/ehealth/documents/e-HIT.xls Conclusions The e-HIT shows potential as a tool for enhancing future e-Health implementations. Further work is needed to make it fully web-enabled, and to determine its predictive potential for future implementations.

  16. The effect of road and environmental characteristics on pedestrian hit-and-run accidents in Ghana.

    Science.gov (United States)

    Aidoo, Eric Nimako; Amoh-Gyimah, Richard; Ackaah, Williams

    2013-04-01

    The number of pedestrians who have died as a result of being hit by vehicles has increased in recent years, in addition to vehicle passenger deaths. Many pedestrians who were involved in road traffic accident died as a result of the driver leaving the pedestrian who was struck unattended at the scene of the accident. This paper seeks to determine the effect of road and environmental characteristics on pedestrian hit-and-run accidents in Ghana. Using pedestrian accident data extracted from the National Road Traffic Accident Database at the Building and Road Research Institute (BRRI) of the Council for Scientific and Industrial Research (CSIR), Ghana, a binary logit model was employed in the analysis. The results from the estimated model indicate that fatal accidents, unclear weather, nighttime conditions, and straight and flat road sections without medians and junctions significantly increase the likelihood that the vehicle driver will leave the scene after hitting a pedestrian. Thus, integrating median separation and speed humps into road design and construction and installing street lights will help to curb the problem of pedestrian hit-and-run accidents in Ghana. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Multi-peak pattern in Multi-gap RPC time-over-threshold distributions and an offline calibration method

    International Nuclear Information System (INIS)

    Yang, R.X.; Li, C.; Sun, Y.J.; Liu, Z.; Wang, X.Z.; Heng, Y.K.; Sun, S.S.; Dai, H.L.; Wu, Z.; An, F.F.

    2017-01-01

    The Beijing Spectrometer (BESIII) has just updated its end-cap Time-of-Flight (ETOF) system, using the Multi-gap Resistive Plate Chamber (MRPC) to replace the current scintillator detectors. These MRPCs shows multi-peak phenomena in their time-over-threshold (TOT) distribution, which was also observed in the Long-strip MRPC built for the RHIC-STAR Muon Telescope Detector (MTD). After carefully investigated the correlation between the multi-peak distribution and incident hit positions along the strips, we find out that it can be semi-quantitatively explained by the signal reflections on the ends of the readout strips. Therefore a new offline calibration method was implemented on the MRPC ETOF data in BESIII, making T-TOT correlation significantly improved to evaluate the time resolution.

  18. Transfer, loss and physical processing of water in hit-and-run collisions of planetary embryos

    Science.gov (United States)

    Burger, C.; Maindl, T. I.; Schäfer, C. M.

    2018-01-01

    Collisions between large, similar-sized bodies are believed to shape the final characteristics and composition of terrestrial planets. Their inventories of volatiles such as water are either delivered or at least significantly modified by such events. Besides the transition from accretion to erosion with increasing impact velocity, similar-sized collisions can also result in hit-and-run outcomes for sufficiently oblique impact angles and large enough projectile-to-target mass ratios. We study volatile transfer and loss focusing on hit-and-run encounters by means of smooth particle hydrodynamics simulations, including all main parameters: impact velocity, impact angle, mass ratio and also the total colliding mass. We find a broad range of overall water losses, up to 75% in the most energetic hit-and-run events, and confirm the much more severe consequences for the smaller body also for stripping of volatile layers. Transfer of water between projectile and target inventories is found to be mostly rather inefficient, and final water contents are dominated by pre-collision inventories reduced by impact losses, for similar pre-collision water mass fractions. Comparison with our numerical results shows that current collision outcome models are not accurate enough to reliably predict these composition changes in hit-and-run events. To also account for non-mechanical losses, we estimate the amount of collisionally vaporized water over a broad range of masses and find that these contributions are particularly important in collisions of ˜ Mars-sized bodies, with sufficiently high impact energies, but still relatively low gravity. Our results clearly indicate that the cumulative effect of several (hit-and-run) collisions can efficiently strip protoplanets of their volatile layers, especially the smaller body, as it might be common, e.g., for Earth-mass planets in systems with Super-Earths. An accurate model for stripping of volatiles that can be included in future planet

  19. Impact of Time-Restricted Feeding and Dawn-to-Sunset Fasting on Circadian Rhythm, Obesity, Metabolic Syndrome, and Nonalcoholic Fatty Liver Disease

    Directory of Open Access Journals (Sweden)

    Ayse L. Mindikoglu

    2017-01-01

    Full Text Available Obesity now affects millions of people and places them at risk of developing metabolic syndrome, nonalcoholic fatty liver disease (NAFLD, and even hepatocellular carcinoma. This rapidly emerging epidemic has led to a search for cost-effective methods to prevent the metabolic syndrome and NAFLD as well as the progression of NAFLD to cirrhosis and hepatocellular carcinoma. In murine models, time-restricted feeding resets the hepatic circadian clock and enhances transcription of key metabolic regulators of glucose and lipid homeostasis. Studies of the effect of dawn-to-sunset Ramadan fasting, which is akin to time-restricted feeding model, have also identified significant improvement in body mass index, serum lipid profiles, and oxidative stress parameters. Based on the findings of studies conducted on human subjects, dawn-to-sunset fasting has the potential to be a cost-effective intervention for obesity, metabolic syndrome, and NAFLD.

  20. Impact of Time-Restricted Feeding and Dawn-to-Sunset Fasting on Circadian Rhythm, Obesity, Metabolic Syndrome, and Nonalcoholic Fatty Liver Disease

    Science.gov (United States)

    Gagan, Sood K.

    2017-01-01

    Obesity now affects millions of people and places them at risk of developing metabolic syndrome, nonalcoholic fatty liver disease (NAFLD), and even hepatocellular carcinoma. This rapidly emerging epidemic has led to a search for cost-effective methods to prevent the metabolic syndrome and NAFLD as well as the progression of NAFLD to cirrhosis and hepatocellular carcinoma. In murine models, time-restricted feeding resets the hepatic circadian clock and enhances transcription of key metabolic regulators of glucose and lipid homeostasis. Studies of the effect of dawn-to-sunset Ramadan fasting, which is akin to time-restricted feeding model, have also identified significant improvement in body mass index, serum lipid profiles, and oxidative stress parameters. Based on the findings of studies conducted on human subjects, dawn-to-sunset fasting has the potential to be a cost-effective intervention for obesity, metabolic syndrome, and NAFLD. PMID:29348746

  1. Pattern recognition with vector hits

    International Nuclear Information System (INIS)

    Frühwirth, R

    2012-01-01

    Trackers at the future high-luminosity LHC, designed to have triggering capability, will feature layers of stacked modules with a small stack separation. This will allow the reconstruction of track stubs or vector hits with position and direction information, but lacking precise curvature information. This opens up new possibilities for track finding, online and offline. Two track finding methods, the Kalman filter and the convergent Hough transform are studied in this context. Results from a simplified fast simulation are presented. It is shown that the performance of the methods depends to a large extent on the size of the stack separation. We conclude that the detector design and the choice of the track finding algorithm(s) are strongly coupled and should proceed conjointly.

  2. Straightforward hit identification approach in fragment-based discovery of bromodomain-containing protein 4 (BRD4) inhibitors.

    Science.gov (United States)

    Borysko, Petro; Moroz, Yurii S; Vasylchenko, Oleksandr V; Hurmach, Vasyl V; Starodubtseva, Anastasia; Stefanishena, Natalia; Nesteruk, Kateryna; Zozulya, Sergey; Kondratov, Ivan S; Grygorenko, Oleksandr O

    2018-05-09

    A combination approach of a fragment screening and "SAR by catalog" was used for the discovery of bromodomain-containing protein 4 (BRD4) inhibitors. Initial screening of 3695-fragment library against bromodomain 1 of BRD4 using thermal shift assay (TSA), followed by initial hit validation, resulted in 73 fragment hits, which were used to construct a follow-up library selected from available screening collection. Additionally, analogs of inactive fragments, as well as a set of randomly selected compounds were also prepared (3 × 3200 compounds in total). Screening of the resulting sets using TSA, followed by re-testing at several concentrations, counter-screen, and TR-FRET assay resulted in 18 confirmed hits. Compounds derived from the initial fragment set showed better hit rate as compared to the other two sets. Finally, building dose-response curves revealed three compounds with IC 50  = 1.9-7.4 μM. For these compounds, binding sites and conformations in the BRD4 (4UYD) have been determined by docking. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Influence of multi-hit capability on quantitative measurement of NiPtSi thin film with laser-assisted atom probe tomography

    International Nuclear Information System (INIS)

    Kinno, T.; Akutsu, H.; Tomita, M.; Kawanaka, S.; Sonehara, T.; Hokazono, A.; Renaud, L.; Martin, I.; Benbalagh, R.; Sallé, B.; Takeno, S.

    2012-01-01

    Highlights: ► Laser-assisted atom probe tomography was applied to NiPtSi films on Si substrates. ► Comparison of depth profiles of single-hit events and those of multi-hit events. ► ∼80% of Pt atoms were detected in multi-hit events. ► Multiple-ion detection is important for Laser-assisted atom probe tomography. - Abstract: Laser-assisted atom probe tomography (LA-APT) was applied to NiPtSi (0, 30, and 50% Pt contents) thin films on Si substrates. Consistent results with those of high-resolution Rutherford backscattering spectrometry (HR-RBS) were obtained. Based on the obtained data sets, the composition profiles from only the signals of single-hit events, meaning detection of one ion by one laser pulse, were compiled. The profiles from only the signals of multi-hit events, meaning detection of multiple ions by one laser pulse, were also compiled. There were large discrepancies with respect to Ni and Pt concentrations among the compiled profiles and the original profiles including the signals of both types of detection events. Additionally, the profiles compiled from single-hit events showed that Si concentration in NiPtSi layer became smaller toward the surface, differing from the original profiles and the multi-hit profiles. These results suggest that capability of simultaneous multiple-ion detection is important for appropriate LA-APT analyses.

  4. Exposure-rate calibration using large-area calibration pads

    International Nuclear Information System (INIS)

    Novak, E.F.

    1988-09-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. A set of large-area, radioelement-enriched concrete pads was constructed by the DOE in 1978 at the Walker Field Airport in Grand Junction for use as calibration standards for airborne gamma-ray spectrometer systems. The use of these pads was investigated by the TMC as potential calibration standards for portable scintillometers employed in measuring gamma-ray exposure rates at Uranium Mill Tailings Remedial Action (UMTRA) project sites. Data acquired on the pads using a pressurized ionization chamber (PIC) and three scintillometers are presented as an illustration of an instrumental calibration. Conclusions and recommended calibration procedures are discussed, based on the results of these data

  5. Hit discovery of Mycobacterium tuberculosis inosine 5'-monophosphate dehydrogenase, GuaB2, inhibitors.

    Science.gov (United States)

    Sahu, Niteshkumar U; Singh, Vinayak; Ferraris, Davide M; Rizzi, Menico; Kharkar, Prashant S

    2018-04-18

    Tuberculosis remains a global concern. There is an urgent need of newer antitubercular drugs due to the development of resistant forms of Mycobacterium tuberculosis (Mtb). Inosine 5'-monophosphate dehydrogenase (IMPDH), guaB2, of Mtb, required for guanine nucleotide biosynthesis, is an attractive target for drug development. In this study, we screened a focused library of 73 drug-like molecules with desirable calculated/predicted physicochemical properties, for growth inhibitory activity against drug-sensitive MtbH37Rv. The eight hits and mycophenolic acid, a prototype IMPDH inhibitor, were further evaluated for activity on purified Mtb-GuaB2 enzyme, target selectivity using a conditional knockdown mutant of guaB2 in Mtb, followed by cross-resistance to IMPDH inhibitor-resistant SRMV2.6 strain of Mtb, and activity on human IMPDH2 isoform. One of the hits, 13, a 5-amidophthalide derivative, has shown growth inhibitory potential and target specificity against the Mtb-GuaB2 enzyme. The hit, 13, is a promising molecule with potential for further development as an antitubercular agent. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Magnetotail Fast Flow Occurrence Rate and Dawn-Dusk Asymmetry at XGSM ˜ -60 RE

    Science.gov (United States)

    Kiehas, S. A.; Runov, A.; Angelopolos, V.; Hietala, H.; Korovinksiy, D.

    2018-03-01

    As a direct result of magnetic reconnection, plasma sheet fast flows act as primary transporter of mass, flux, and energy in the Earth's magnetotail. During the last decades, these flows were mainly studied within XGSM>-60RE, as observations near or beyond lunar orbit were limited. By using 5 years (2011-2015) of ARTEMIS (Acceleration, Reconnection, Turbulence, and Electrodynamics of the Moons Interaction with the Sun) data, we statistically investigate earthward and tailward flows at around 60 RE downtail. A significant fraction of fast flows is directed earthward, comprising 43% (vx>400 km/s) to 56% (vx>100 km/s) of all observed flows. This suggests that near-Earth and midtail reconnection are equally probable of occurring on either side of the ARTEMIS downtail distance. For fast convective flows (v⊥x>400 km/s), this fraction of earthward flows is reduced to about 29%, which is in line with reconnection as source of these flows and a downtail decreasing Alfvén velocity. More than 60% of tailward convective flows occur in the dusk sector (as opposed to the dawn sector), while earthward convective flows are nearly symmetrically distributed between the two sectors for low AL (>-400 nT) and asymmetrically distributed toward the dusk sector for high AL (infer that near-Earth reconnection is preferentially located at dusk, whereas midtail reconnection (X >- 60RE) is likely symmetric across the tail during weak substorms and asymmetric toward the dusk sector for strong substorms, as the dawn-dusk asymmetric nature of reconnection onset in the near-Earth region progresses downtail.

  7. The probability of a tornado missile hitting a target

    International Nuclear Information System (INIS)

    Goodman, J.; Koch, J.E.

    1983-01-01

    It is shown that tornado missile transportation is a diffusion Markovian process. Therefore, the Green's function method is applied for the estimation of the probability of hitting a unit target area. This propability is expressed through a joint density of tornado intensity and path area, a probability of tornado missile injection and a tornado missile height distribution. (orig.)

  8. Effects of Experimental Volleyball Rules Quantified by Type and Number of Jumps, Hits and Contacts

    Directory of Open Access Journals (Sweden)

    Mladen Stankovic

    2017-10-01

    Full Text Available The purpose of this study was to determine the influence of the two new rules tested at the inaugural U23 Men’s Volleyball World Championship (21-point set excluding the fifth set, and 15 seconds between rallies–10 seconds from the finished point until the referee’s whistle for serve and five seconds for performing the serve on number and types of jumps and number of contacts and hits. The analysis comprised 25,930 jumps (an essential physical activity for volleyball, 15,706 contacts and 10,224 hits during 36 matches played by 144 males aged under 23 at the first Under 23 Men’s World Championships organized in Uberlandia, Brazil, in 2013. Two investigations were conducted: 1 Analysis of jumps by Jump type, In-game role and Level of set win; 2 Analysis of contacts (reception, setting, block, defense and hits (serve and attack by Type, In-game role and Set outcome. Significant differences (p=0.000 were found between in-game role and jump type, as Middle blocker performed the most (34.7%, followed by Outside hitter (24.9%, Setter (24.6% and Opposite (15.8%. Significant differences were found for number and types of Hits between set Winner and Loser teams only for serves by Setter (p<0.001 and Middle blocker (p<0.05. The results showed major differences in jumps, hits and contacts between in-game roles: Middle blocker was the most frequent jumping position, followed by Outside hitter and Setter. The Libero showed a new tendency of being Setter with a jump after the initial Setter defense.

  9. Influence of Human Leukocyte Antigen (HLA) Alleles and Killer Cell Immunoglobulin-Like Receptors (KIR) Types on Heparin-Induced Thrombocytopenia (HIT).

    Science.gov (United States)

    Karnes, Jason H; Shaffer, Christian M; Cronin, Robert; Bastarache, Lisa; Gaudieri, Silvana; James, Ian; Pavlos, Rebecca; Steiner, Heidi E; Mosley, Jonathan D; Mallal, Simon; Denny, Joshua C; Phillips, Elizabeth J; Roden, Dan M

    2017-09-01

    Heparin-induced thrombocytopenia (HIT) is an unpredictable, life-threatening, immune-mediated reaction to heparin. Variation in human leukocyte antigen (HLA) genes is now used to prevent immune-mediated adverse drug reactions. Combinations of HLA alleles and killer cell immunoglobulin-like receptors (KIR) are associated with multiple autoimmune diseases and infections. The objective of this study is to evaluate the association of HLA alleles and KIR types, alone or in the presence of different HLA ligands, with HIT. HIT cases and heparin-exposed controls were identified in BioVU, an electronic health record coupled to a DNA biobank. HLA sequencing and KIR type imputation using Illumina OMNI-Quad data were performed. Odds ratios for HLA alleles and KIR types and HLA*KIR interactions using conditional logistic regressions were determined in the overall population and by race/ethnicity. Analysis was restricted to KIR types and HLA alleles with a frequency greater than 0.01. The p values for HLA and KIR association were corrected by using a false discovery rate qHIT cases and 350 matched controls were identified. No statistical differences in baseline characteristics were observed between cases and controls. The HLA-DRB3*01:01 allele was significantly associated with HIT in the overall population (odds ratio 2.81 [1.57-5.02], p=2.1×10 -4 , q=0.02) and in individuals with European ancestry, independent of other alleles. No KIR types were associated with HIT, although a significant interaction was observed between KIR2DS5 and the HLA-C1 KIR binding group (p=0.03). The HLA-DRB3*01:01 allele was identified as a potential risk factor for HIT. This class II HLA gene and allele represent biologically plausible candidates for influencing HIT pathogenesis. We found limited evidence of the role of KIR types in HIT pathogenesis. Replication and further study of the HLA-DRB3*01:01 association is necessary. © 2017 Pharmacotherapy Publications, Inc.

  10. Prediction of Potential Hit Song and Musical Genre Using Artificial Neural Networks

    Science.gov (United States)

    Monterola, Christopher; Abundo, Cheryl; Tugaff, Jeric; Venturina, Lorcel Ericka

    Accurately quantifying the goodness of music based on the seemingly subjective taste of the public is a multi-million industry. Recording companies can make sound decisions on which songs or artists to prioritize if accurate forecasting is achieved. We extract 56 single-valued musical features (e.g. pitch and tempo) from 380 Original Pilipino Music (OPM) songs (190 are hit songs) released from 2004 to 2006. Based on an effect size criterion which measures a variable's discriminating power, the 20 highest ranked features are fed to a classifier tasked to predict hit songs. We show that regardless of musical genre, a trained feed-forward neural network (NN) can predict potential hit songs with an average accuracy of ΦNN = 81%. The accuracy is about +20% higher than those of standard classifiers such as linear discriminant analysis (LDA, ΦLDA = 61%) and classification and regression trees (CART, ΦCART = 57%). Both LDA and CART are above the proportional chance criterion (PCC, ΦPCC = 50%) but are slightly below the suggested acceptable classifier requirement of 1.25*ΦPCC = 63%. Utilizing a similar procedure, we demonstrate that different genres (ballad, alternative rock or rock) of OPM songs can be automatically classified with near perfect accuracy using LDA or NN but only around 77% using CART.

  11. Intercomparison and calibration of dose calibrators used in nuclear medicine facilities

    CERN Document Server

    Costa, A M D

    2003-01-01

    The aim of this work was to establish a working standard for intercomparison and calibration of dose calibrators used in most of nuclear medicine facilities for the determination of the activity of radionuclides administered to patients in specific examinations or therapeutic procedures. A commercial dose calibrator, a set of standard radioactive sources, and syringes, vials and ampoules with radionuclide solutions used in nuclear medicine were utilized in this work. The commercial dose calibrator was calibrated for radionuclide solutions used in nuclear medicine. Simple instrument tests, such as linearity response and variation response with the source volume at a constant source activity concentration were performed. This instrument may be used as a reference system for intercomparison and calibration of other activity meters, as a method of quality control of dose calibrators utilized in nuclear medicine facilities.

  12. The Dawn of Human Matrilineal Diversity

    Science.gov (United States)

    Behar, Doron M.; Villems, Richard; Soodyall, Himla; Blue-Smith, Jason; Pereira, Luisa; Metspalu, Ene; Scozzari, Rosaria; Makkan, Heeran; Tzur, Shay; Comas, David; Bertranpetit, Jaume; Quintana-Murci, Lluis; Tyler-Smith, Chris; Wells, R. Spencer; Rosset, Saharon

    2008-01-01

    The quest to explain demographic history during the early part of human evolution has been limited because of the scarce paleoanthropological record from the Middle Stone Age. To shed light on the structure of the mitochondrial DNA (mtDNA) phylogeny at the dawn of Homo sapiens, we constructed a matrilineal tree composed of 624 complete mtDNA genomes from sub-Saharan Hg L lineages. We paid particular attention to the Khoi and San (Khoisan) people of South Africa because they are considered to be a unique relic of hunter-gatherer lifestyle and to carry paternal and maternal lineages belonging to the deepest clades known among modern humans. Both the tree phylogeny and coalescence calculations suggest that Khoisan matrilineal ancestry diverged from the rest of the human mtDNA pool 90,000–150,000 years before present (ybp) and that at least five additional, currently extant maternal lineages existed during this period in parallel. Furthermore, we estimate that a minimum of 40 other evolutionarily successful lineages flourished in sub-Saharan Africa during the period of modern human dispersal out of Africa approximately 60,000–70,000 ybp. Only much later, at the beginning of the Late Stone Age, about 40,000 ybp, did introgression of additional lineages occur into the Khoisan mtDNA pool. This process was further accelerated during the recent Bantu expansions. Our results suggest that the early settlement of humans in Africa was already matrilineally structured and involved small, separately evolving isolated populations. PMID:18439549

  13. Concentrated Hitting Times of Randomized Search Heuristics with Variable Drift

    DEFF Research Database (Denmark)

    Lehre, Per Kristian; Witt, Carsten

    2014-01-01

    Drift analysis is one of the state-of-the-art techniques for the runtime analysis of randomized search heuristics (RSHs) such as evolutionary algorithms (EAs), simulated annealing etc. The vast majority of existing drift theorems yield bounds on the expected value of the hitting time for a target...

  14. Variation in number of hits for complex searches in Google Scholar

    Directory of Open Access Journals (Sweden)

    Wichor Matthijs Bramer, BSc

    2016-11-01

    Full Text Available Objective: Google Scholar is often used to search for medical literature. Numbers of results reported by Google Scholar outperform the numbers reported by traditional databases. How reliable are these numbers? Why are often not all available 1,000 references shown? Methods: For several complex search strategies used in systematic review projects, the number of citations and the total number of versions were calculated. Several search strategies were followed over a two-year period, registering fluctuations in reported search results. Results: Changes in numbers of reported search results varied enormously between search strategies and dates. Theories for calculations of the reported and shown number of hits were not proved. Conclusions: The number of hits reported in Google Scholar is an unreliable measure. Therefore, its repeatability is problematic, at least when equal results are needed.

  15. Structure of the auroral precipitation region in the dawn sector: relationship to convection reversal boundaries and field-aligned currents

    Directory of Open Access Journals (Sweden)

    Y. I. Feldstein

    2001-05-01

    precipitation (AO is mapped to the dawn periphery of the Central Plasma Sheet (CPS; the soft small scale structured precipitation (SSSL is mapped to the outer magnetosphere close to the magnetopause, i.e. the Low Latitude Boundary Layer (LLBL. In the near-noon sector, earthward fluxes of soft electrons, which cause the Diffuse Red Aurora (DRA, are observed. The ion energies decrease with increasing latitude. The plasma spectra of the DRA regime are analogous to the spectra of the Plasma Mantle (PM. In the dawn sector, the large-scale field-aligned currents flow into the ionosphere at the SSSL latitudes (Region 1 and flow out at the AO or DAZ latitudes (Region 2. In the dawn and dusk sectors, the large-scale Region 1 and Region 2 FAC generation occurs in different plasma domains of the distant magnetosphere. The dawn and dusk FAC connection to the traditional Region 1 and Region 2 has only formal character, as FAC generating in various magnetospheric plasma domains integrate in the same region (Region 1 or Region 2. In the SSSL, there is anti-sunward convection; in the DAZ and the AO, there is the sunward convection. At PM latitudes, the convection is controlled by the azimuthal IMF component (By . It is suggested to extend the notation of the plasma pattern boundaries, as proposed by Newell et al. (1996, for the nightside sector of the auroral oval to the dawn sector.Key words. Magnetospheric physics (current systems; magnetospheric configuration and dynamics; plasma convection

  16. Structure of the auroral precipitation region in the dawn sector: relationship to convection reversal boundaries and field-aligned currents

    Directory of Open Access Journals (Sweden)

    Y. I. Feldstein

    electrons and isotropic ion precipitation (AO is mapped to the dawn periphery of the Central Plasma Sheet (CPS; the soft small scale structured precipitation (SSSL is mapped to the outer magnetosphere close to the magnetopause, i.e. the Low Latitude Boundary Layer (LLBL. In the near-noon sector, earthward fluxes of soft electrons, which cause the Diffuse Red Aurora (DRA, are observed. The ion energies decrease with increasing latitude. The plasma spectra of the DRA regime are analogous to the spectra of the Plasma Mantle (PM. In the dawn sector, the large-scale field-aligned currents flow into the ionosphere at the SSSL latitudes (Region 1 and flow out at the AO or DAZ latitudes (Region 2. In the dawn and dusk sectors, the large-scale Region 1 and Region 2 FAC generation occurs in different plasma domains of the distant magnetosphere. The dawn and dusk FAC connection to the traditional Region 1 and Region 2 has only formal character, as FAC generating in various magnetospheric plasma domains integrate in the same region (Region 1 or Region 2. In the SSSL, there is anti-sunward convection; in the DAZ and the AO, there is the sunward convection. At PM latitudes, the convection is controlled by the azimuthal IMF component (By . It is suggested to extend the notation of the plasma pattern boundaries, as proposed by Newell et al. (1996, for the nightside sector of the auroral oval to the dawn sector.

    Key words. Magnetospheric physics (current systems; magnetospheric configuration and dynamics; plasma convection

  17. Spontaneous HIT syndrome post-knee replacement surgery with delayed recovery of thrombocytopenia: a case report and literature review.

    Science.gov (United States)

    Poudel, Dilli Ram; Ghimire, Sushil; Dhital, Rashmi; Forman, Daniel A; Warkentin, Theodore E

    2017-09-01

    Recently published reports have established a heparin-induced thrombocytopenia (HIT)-mimicking thromboembolic disorder without proximate heparin exposure, called spontaneous HIT syndrome. Although the pathophysiology remains unclear, anti-platelet factor 4 (PF4)/heparin antibodies possibly triggered by exposure to knee cartilage glycosaminoglycans or other non-heparin polyanions found on bacterial surfaces and nucleic acids have been postulated. We present a 53-year-old female receiving antithrombotic prophylaxis with aspirin following right total knee replacement surgery (without perioperative or any previous lifetime heparin exposure) who acutely presented with high-risk pulmonary embolism (PE) and right great saphenous vein thrombophlebitis on postoperative day (POD) 14; her platelet count at presentation was 13 × 10 9 /L. Prior to diagnostic consideration of spontaneous HIT syndrome, the patient briefly received unfractionated heparin (UFH) and one dose of enoxaparin. The patient's serum tested strongly positive for anti-PF4/heparin antibodies by two different PF4-dependent enzyme-linked immunosorbent assays (ELISAs) and by serotonin release assay (SRA). Failure of fondaparinux anticoagulation (persisting HIT-associated disseminated intravascular coagulation) prompted switching to argatroban. Severe thrombocytopenia persisted (platelet count nadir, 12 × 10 9 /L, on POD21), and 9 days after starting argatroban symptomatic right leg deep-vein thrombosis (DVT) occurred, prompting switch to rivaroxaban. Thereafter, her course was uneventful, although platelet count recovery was prolonged, reaching 99 × 10 9 /L by POD45 and 199 × 10 9 /L by POD79. The patient's serum elicited strong serotonin release in the absence of heparin (seen even with 1/32 serum dilution) that was enhanced by pharmacological concentrations of UFH (0.1 and 0.3 IU/mL) and fondaparinux (0.1-1.2 μg/mL, i.e., in vitro fondaparinux "cross-reactivity"). Ultimately, platelet count recovery was

  18. An automated single ion hit at JAERI heavy ion microbeam to observe individual radiation damage

    International Nuclear Information System (INIS)

    Kamiya, Tomihiro; Sakai, Takuro; Naitoh, Yutaka; Hamano, Tsuyoshi; Hirao, Toshio

    1999-01-01

    Microbeam scanning and a single ion hit technique have been combined to establish an automated beam positioning and single ion hit system at the JAERI Takasaki heavy ion microbeam system. Single ion irradiation on preset points of a sample in various patterns can be performed automatically in a short period. The reliability of the system was demonstrated using CR-39 nuclear track detectors. Single ion hit patterns were achieved with a positioning accuracy of 2 μm or less. In measurement of single event transient current using this system, the reduction of the pulse height by accumulation of radiation damages was observed by single ion injection to the same local areas. This technique showed a possibility to get some quantitative information about the lateral displacement of an individual radiation effect in silicon PIN photodiodes. This paper will give details of the irradiation system and present results from several experiments

  19. Comparison of validity and reliability of the Migraine disability assessment (MIDAS) versus headache impact test (HIT) in an Iranian population.

    Science.gov (United States)

    Ghorbani, Abbas; Chitsaz, Ahmad

    2011-01-01

    Migraine is one of the most common headaches that affect 11% or more adult population. Recently, researchers have designed two questionnaires, namely Headache Impact Test (HIT) and Migraine Disability Assessment (MIDAS), with the aim of improving migraine care. These two tests provide a standard measurement about migraine's effects on people's life style that divide patients into 4 groups (grades) based on headaches intensity. The aim of this study was to compare the validity and reliability of these two tests. This study was designed as a multicenter, descriptive study to compare validity and reliability of Persian version of MIDAS and HIT questionnaires in 240 males and females with a migraine diagnosis according to criteria for headache and facial pain of the International Headache Society (IHS). The patients were enrolled in the study from 3 neurology clinics in Isfahan, Iran, between July 2004 and January 2005 and were evaluated at baseline (visit 1) and 4 weeks later (visit 2). According to our study, there was a high correlation between two tests (r = 0.94). This decreased their MIDAS grade in comparison to their grade HIT questionnaire. These findings demonstrated that Persian version of HIT have the same validity and reliability as MIDAS. Replying to HIT questionnaire was easier than MIDAS for Iranian patients. Physicians can reliably use the Persian translation of both MIDAS and HIT questionnaires to define the severity of illness and its treatment strategy as a self-administered report by migraine patients. However, we recommend HIT for its simplicity in headache clinics.

  20. Validation of a densimeter calibration procedure for a secondary calibration laboratory

    International Nuclear Information System (INIS)

    Alpizar Herrera, Juan Carlos

    2014-01-01

    A survey was conducted to quantify the need for calibration of a density measurement instrument at the research units at the Sede Rodrigo Facio of the Universidad de Costa Rica. A calibration procedure was documented for the instrument that presented the highest demand in the survey by the calibration service. A study of INTE-ISO/IEC 17025: 2005 and specifically in section 5.4 of this standard was done, to document the procedure for calibrating densimeters. Densimeter calibration procedures and standards were sought from different national and international sources. The method of hydrostatic weighing or Cuckow method was the basis of the defined procedure. Documenting the calibration procedure and creating other documents was performed for data acquisition log, intermediate calculation log and calibration certificate copy. A veracity test was performed using as reference laboratory a laboratory of calibration secondary national as part of the validation process of the documented procedure. The results of the E_n statistic of 0.41; 0.34 and 0.46 for the calibration points 90%, 50% and 10% were obtained for the densimeter scale respectively. A reproducibility analysis of the method was performed with satisfactory results. Different suppliers were contacted to estimate the economic costs of the equipment and materials, needed to develop the documented method of densimeter calibration. The acquisition of an analytical balance was recommended, instead of a precision scale, in order to improve the results obtained with the documented method [es

  1. X-hitting: A new algorithm for novelty detection and dereplication by UV spectra of complex mixtures of natural products

    DEFF Research Database (Denmark)

    Hansen, Michael Edberg; Smedsgaard, Jørn; Larsen, Thomas Ostenfeld

    2005-01-01

    A major challenge in lead discovery is to detect well-known and trivial compounds rapidly, a process known as dereplication, so that isolation, structure elucidation, and pharmacological investigations can be focused on novel compounds. In this paper, we present a new algorithm, X-hitting, based...... on cross sample comparison of full UV spectra from HPLC analysis of highly complex natural product extracts/samples. X-Hitting allows automatic identification of known compounds but more important also allows finding of potentially new or similar compounds. We demonstrate this new algorithm by automatic...... identification of known structures, a task we call cross-hitting, and tentative identification of potentially new bioactive compounds, a task we call new-hitting, in HPLC data from analysis of fungal extracts. Both tasks are illustrated using 18 important reference compounds and complex fungal extracts obtained...

  2. The accelerator facility of the Heidelberg Ion-Beam Therapy Centre (HIT)

    Science.gov (United States)

    Peters, Andreas

    The following sections are included: * Introduction * Beam parameters * General layout of the HIT facility * The accelerator chain in detail * Operational aspects of a particle therapy facility * 24/7 accelerator operation at 335 days per year * Safety and regulatory aspects * Status and perspectives * References

  3. 76 FR 39107 - HIT Standards Committee's Workgroup Meetings; Notice of Meetings

    Science.gov (United States)

    2011-07-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES HIT Standards Committee's Workgroup Meetings; Notice of Meetings AGENCY: Office of the National Coordinator for Health Information Technology, HHS. ACTION: Notice... of the Office of the National Coordinator for Health Information Technology (ONC). The [[Page 39108...

  4. Optimal Fixed-Interval Integrated Guidance-Control Laws for Hit-to-Kill Missiles

    National Research Council Canada - National Science Library

    Menon, P. K; Sweriduk, G. D; Ohlmeyer, E. J

    2003-01-01

    Due to their potential for reducing the weapon size and efficiency, design methods for realizing hit-to- kill capabilities in missile systems are of significant research interest in the missile flight control community...

  5. ORNL calibrations facility

    International Nuclear Information System (INIS)

    Berger, C.D.; Gupton, E.D.; Lane, B.H.; Miller, J.H.; Nichols, S.W.

    1982-08-01

    The ORNL Calibrations Facility is operated by the Instrumentation Group of the Industrial Safety and Applied Health Physics Division. Its primary purpose is to maintain radiation calibration standards for calibration of ORNL health physics instruments and personnel dosimeters. This report includes a discussion of the radioactive sources and ancillary equipment in use and a step-by-step procedure for calibration of those survey instruments and personnel dosimeters in routine use at ORNL

  6. Measurement Uncertainty Analysis of an Accelerometer Calibration Using a POC Electromagnetic Launcher

    Energy Technology Data Exchange (ETDEWEB)

    Timpson, Erik J.; Engel, T. G.

    2012-06-12

    A pulse forming network (PFN), helical electromagnetic launcher (HEML), command module (CM), and calibration table (CT) were built and evaluated for the combined ability to calibrate an accelerometer. The PFN has a maximum stored nergy of 19.25 kJ bank and is fired by a silicon controlled rectifier (SCR), with appropriate safety precautions. The HEML is constructed out of G-10 fiberglass reinforced epoxy and is designed to accelerate a mass of 600 grams to a velocity of 10 meters per second. The CM is microcontroller-based running Arduino Software. The CM has a keypad input and 7 segment outputs of the PFN voltage and desired charging voltage. After entering a desired PFN voltage, the CM controls the charging of the PFN. When the two voltages are equal it sends a pulse to the SCR to fire the PFN and in turn, the HEML. The HEML projectile’s tip hits a target that is held by the CT. The CT consists of a table to hold the PFN and HEML, a vacuum chuck, air bearing, velocimeter and catch pot. The target is held with the vacuum chuck awaiting impact. After impact, the air bearing allows the target to fall freely so that the velocimeter can accurately read. A known acceleration is determined from the known change in velocity of the target. Thus, if an accelerometer was attached to the target, the measured value can be compared to the known value.

  7. Selective histone deacetylase 6 inhibition prolongs survival in a lethal two-hit model.

    Science.gov (United States)

    Cheng, Xin; Liu, Zhengcai; Liu, Baoling; Zhao, Ting; Li, Yongqing; Alam, Hasan B

    2015-07-01

    Hemorrhagic shock (HS) followed by a subsequent insult ("second hit") often initiates an exaggerated systemic inflammatory response and multiple organ failure. We have previously demonstrated that valproic acid, a pan histone deacetylase inhibitor, could improve survival in a rodent "two-hit" model. In the present study, our goal was to determine whether selective inhibition of histone deacetylase 6 with Tubastatin A (Tub-A) could prolong survival in a two-hit model where HS was followed by sepsis from cecal ligation and puncture (CLP). C57Bl/6J mice were subjected to sublethal HS (30% blood loss) and then randomly divided into two groups (n = 13 per group) such as Tub-A group (treatment) and vehicle (VEH) group (control). The Tub-A group was given an intraperitoneal injection of Tub-A (70 mg/kg) dissolved in dimethyl sulfoxide (DMSO). The VEH group was injected with DMSO (1 μl/g body weight). After 24 h, all mice were subjected CLP followed immediately by another dose of Tub-A or DMSO. Survival was monitored for 10 d. In a parallel study, peritoneal irrigation fluid and liver tissue from Tub-A- or DMSO-treated mice were collected 3 h after CLP. Enzyme-linked immunosorbent assay was performed to quantify activity of the myeloperoxidase and concentrations of tumor necrosis factor-alpha (TNF-α) and interleukin 6 (IL-6) in the peritoneal irrigation fluid. RNA was isolated from the liver tissue, and real-time polymerase chain reaction was performed to measure relative messenger RNA levels of TNF-α and IL-6. Treatment with Tub-A significantly improved survival compared with that of the control (69.2% versus 15.4%). In addition, Tub-A significantly suppressed myeloperoxidase activity (169.9 ± 8.4 ng/mL versus 70.4 ± 17.4 ng/mL; P hit model. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Constraining Cosmic Dawn and Cosmological Reionization via the global redshifted 21-cm signal

    Science.gov (United States)

    Singh, Saurabh

    2018-01-01

    The formation of first stars and consequent thermal evolution in baryons during Cosmic Dawn and the Epoch of Reionization (EoR) is poorly constrained. The 21-cm line transition of neutral hydrogen is one of the richest probes of the astrophysics during this era. The signal has the potential to reveal the nature and timing of the emergence of first stars, first light, and the consequent evolution in thermal and ionization state of the baryons.The detection of the global redshifted 21-cm signal, which represents the mean thermal history of the gas, is challenging since it is extremely faint and seen through orders of magnitude stronger contributions from Galactic and extragalactic foregrounds. Man-made terrestrial Radio Frequency Interference (RFI) and the exacting tolerances required on instrument systematics make the detection even more daunting.The design considerations for a precision spectral radiometer are first listed, and a comparison is made of different radiometer configurations, including short and zero baseline interferometers along with methods to enhance the response. We discuss the relative merits of different methods.We then describe SARAS 2, a spectral radiometer custom-designed for precision measurement of the global 21-cm signal. SARAS 2 has been designed to have a system transfer function and internal systematics – both multiplicative and additive – to be spectrally smooth so as to allow a separation of foregrounds and systematics from plausible and predicted global cosmological 21-cm signals. The algorithms for calibration and RFI mitigation are carefully developed so that they do not introduce spectral features that may confuse the detection of the 21-cm signal.We present the outcomes for cosmology from analysis of 60 hr observing with the radiometer deployed at the Timbaktu Collective in Southern India. The detailed analysis of the data reveals an RMS noise level of 11 mK, without being limited by systematic structures. The likelihood

  9. Interactive football training based on rebounders with hit position sensing and audio/light feedback

    DEFF Research Database (Denmark)

    Jensen, Mads Møller; Grønbæk, Kaj; Rasmussen, Majken Kirkegård

    A Danish football club has established a (24/7/365) football training facility, where the authors developed an interactive training installation (http://vimeo.com/28446312). The training installation consist of a 12*12 m square with 4 M­Station Pro rebounders equipped with sensors that enable hit...... position sensing. The rebounders are equipped with loudspeakers and lights being used to call for the ball. Here we discuss one game “Pass ­and ­Turn”, which is meant to train speed in controlling a returned ball, reaction to a call for the ball and turning to hit rebounders to the left, right, behind...

  10. SCIAMACHY Level 1 data: calibration concept and in-flight calibration

    Science.gov (United States)

    Lichtenberg, G.; Kleipool, Q.; Krijger, J. M.; van Soest, G.; van Hees, R.; Tilstra, L. G.; Acarreta, J. R.; Aben, I.; Ahlers, B.; Bovensmann, H.; Chance, K.; Gloudemans, A. M. S.; Hoogeveen, R. W. M.; Jongma, R. T. N.; Noël, S.; Piters, A.; Schrijver, H.; Schrijvers, C.; Sioris, C. E.; Skupin, J.; Slijkhuis, S.; Stammes, P.; Wuttke, M.

    2006-11-01

    The calibration of SCIAMACHY was thoroughly checked since the instrument was launched on-board ENVISAT in February 2002. While SCIAMACHY's functional performance is excellent since launch, a number of technical difficulties have appeared, that required adjustments to the calibration. The problems can be separated into three types: (1) Those caused by the instrument and/or platform environment. Among these are the high water content in the satellite structure and/or MLI layer. This results in the deposition of ice on the detectors in channels 7 and 8 which seriously affects the retrievals in the IR, mostly because of the continuous change of the slit function caused by scattering of the light through the ice layer. Additionally a light leak in channel 7 severely hampers any retrieval from this channel. (2) Problems due to errors in the on-ground calibration and/or data processing affecting for example the radiometric calibration. A new approach based on a mixture of on-ground and in-flight data is shortly described here. (3) Problems caused by principal limitations of the calibration concept, e.g. the possible appearance of spectral structures after the polarisation correction due to unavoidable errors in the determination of atmospheric polarisation. In this paper we give a complete overview of the calibration and problems that still have to be solved. We will also give an indication of the effect of calibration problems on retrievals where possible. Since the operational processing chain is currently being updated and no newly processed data are available at this point in time, for some calibration issues only a rough estimate of the effect on Level 2 products can be given. However, it is the intention of this paper to serve as a future reference for detailed studies into specific calibration issues.

  11. Madoff Debacle Hits Colleges and Raises Questions about Trustee Conflicts

    Science.gov (United States)

    Fain, Paul

    2009-01-01

    Several colleges and universities lost millions in the alleged $50-billion Ponzi scheme run by the Wall Street trader Bernard L. Madoff. The losses include institutions' endowment holdings in hedge funds that were invested with Madoff as well as hits taken by supporting foundations and donors. Several foundations that have been active in higher…

  12. The Surface and Interior Evolution of Ceres Revealed by Analysis of Fractures and Secondary Crater Chains Using Dawn Data

    Science.gov (United States)

    Scully, J. E. C.; Buczkowski, D.; King, S. D.; Castillo, J. C.; Schmedemann, N.; Raymond, C. A.; O'Brien, D. P.; Marchi, S.; Russell, C. T.; Mitri, G.; Bland, M. T.

    2016-12-01

    Dawn is the first spacecraft to visit and orbit Ceres, a dwarf planet and the largest body in the asteroid belt (radius 470 km) (Russell et al., 2016). Previously, telescopic observations and thermal evolution modeling indicated Ceres was at least partially differentiated, with a density of 2,100 kg/m3 (e.g. Drummond et al., 2014; Castillo-Rogez & McCord, 2010). Moreover, models of crater retention predicted that pervasive viscous relaxation in a water-ice-rich outer layer could erase most surface features (Bland, 2013). However, a full understanding of Ceres' surface and interior evolution remained elusive until Dawn explored Ceres. Here we present a global geologic map of Ceres' ≥1 km wide linear features, which we interpret as: 1) the surface expression of subsurface fractures, and 2) secondary crater chains formed when material ejected during impact-crater formation impacts and scours the surface. The formation and preservation of these linear features indicate Ceres' outer layer is relatively strong, and not dominated by viscous relaxation as predicted (Buczkowski et al., 2016). The fractures (called the Samhain Catenae) give us insights into the interior. Based on a fracture spacing to fractured layer thickness ratio of 1 (Bai & Pollard, 2000), the spacing of the Samhain Catenae indicates that the outer, fractured layer is 88 km thick. Moreover, consistent with geodynamic modeling (King et al., 2016), we interpret the Samhain Catenae formed because of uplift and extension induced by an upwelling region. Unlike many cerean secondary crater chains, the Junina Catenae secondary crater chains are not radial to their source impact crater(s). On account of Ceres' fast rotation (period of 9 hours) and relatively small radius, modeling indicates that the Junina Catenae originated from the Urvara/Yalode impact craters, which are located in a different hemisphere. Our results show Ceres has different surface and interior characteristics than predicted, and underwent

  13. Recent results from the HIT-II and HIT-SI helicity injection current drive experiments

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Hamp, W.T.; Izzo, V.A.; Nelson, B.A.; O'Neill, R.G.; Raman, R.; Redd, A.J.; Sieck, P.E.; Smith, R.J.

    2005-01-01

    Three important results are reported. 1) CHI startup has produced 100 kA of closed current without using poloidal field (PF) coils or any transformer action. The initial equilibrium is then driven to 240 kA with a 3 V transformer loop voltage, indicating high quality plasma. 2) For the first time CHI alone has produced toroidal currents (350 kA) that far exceed q a I inj , and with I p /I tf as high as 1.2. The key to these new results appears to be having the toroidal field small enough that relaxation will occur. 3) The steady inductive helicity injection spheromak experiment has operated at 5 kHz for 6 ms with current amplitudes up to 11 kA in each injector. The helicity injection rate is nearly constant with the ExB flow always into the plasma and not into the walls. NIMROD simulations of HIT-SI show a buildup of spheromak fields. (author)

  14. Spitzer/JWST Cross Calibration: IRAC Observations of Potential Calibrators for JWST

    Science.gov (United States)

    Carey, Sean J.; Gordon, Karl D.; Lowrance, Patrick; Ingalls, James G.; Glaccum, William J.; Grillmair, Carl J.; E Krick, Jessica; Laine, Seppo J.; Fazio, Giovanni G.; Hora, Joseph L.; Bohlin, Ralph

    2017-06-01

    We present observations at 3.6 and 4.5 microns using IRAC on the Spitzer Space Telescope of a set of main sequence A stars and white dwarfs that are potential calibrators across the JWST instrument suite. The stars range from brightnesses of 4.4 to 15 mag in K band. The calibration observations use a similar redundancy to the observing strategy for the IRAC primary calibrators (Reach et al. 2005) and the photometry is obtained using identical methods and instrumental photometric corrections as those applied to the IRAC primary calibrators (Carey et al. 2009). The resulting photometry is then compared to the predictions based on spectra from the CALSPEC Calibration Database (http://www.stsci.edu/hst/observatory/crds/calspec.html) and the IRAC bandpasses. These observations are part of an ongoing collaboration between IPAC and STScI investigating absolute calibration in the infrared.

  15. ORIGIN: Metal Creation and Evolution from the Cosmic Dawn

    CERN Document Server

    Herder, Jan-Willem den; Ohashi, Takaya; Kouveliotou, Chryssa; Hartmann, Dieter H.; Kaastra, Jelle S.; Amati, L.; Andersen, M.I.; Arnaud, M.; Attéia, J.-L.; Bandler, S.; Barbera, M.; Barcons, X.; Barthelmy, S.; Basa, S.; Basso, S.; Boer, M.; Branchini, E.; Branduardi-Raymont, G.; Borgani, S.; Boyarsky, A.; Brunetti, G.; Budtz-Jorgensen, C.; Burrows, D.; Butler, N.; Campana, S.; Caroli, E.; Ceballos, M.; Christensen, F.; Churazov, E.; Comastri, A.; Colasanti, L.; Cole, R.; Content, R.; Corsi, A.; Costantini, E.; Conconi, P.; Cusumano, G.; de Plaa, J.; De Rosa, A.; Del Santo, M.; Di Cosimo, S.; De Pasquale, M.; Doriese, R.; Ettori, S.; Evans, P.; Ezoe, Y.; Ferrari, L.; Finger, H.; Figueroa-Feliciano, T.; Friedrich, P.; Fujimoto, R.; Furuzawa, A.; Fynbo, J.; Gatti, F.; Galeazzi, M.; Gehrels, N.; Gendre, B.; Ghirlanda, G.; Ghisellini, G.; Gilfanov, M.; Giommi, P.; Girardi, M.; Grindlay, J.; Cocchi, M.; Godet, O.; Guedel, M.; Haardt, F.; den Hartog, R.; Hepburn, I.; Hermsen, W.; Hjorth, J.; Hoekstra, H.; Holland, A.; Hornstrup, A.; van der Horst, A.; Hoshino, A.; in 't Zand, J.; Irwin, K.; Ishisaki, Y.; Jonker, P.; Kitayama, T.; Kawahara, H.; Kawai, N.; Kelley, R.; Kilbourne, C.; de Korte, P.; Kusenko, A.; Kuvvetli, I.; Labanti, M.; Macculi, C.; Maiolino, R.; Hesse, M. Mas; Matsushita, K.; Mazzotta, P.; McCammon, D.; Méndez, M.; Mignani, R.; Mineo, T.; Mitsuda, K.; Mushotzky, R.; Molendi, S.; Moscardini, L.; Natalucci, L.; Nicastro, F.; O'Brien, P.; Osborne, J.; Paerels, F.; Page, M.; Paltani, S.; Pedersen, K.; Perinati, E.; Ponman, T.; Pointecouteau, E.; Predehl, P.; Porter, S.; Rasmussen, A.; Rauw, G.; Röttgering, H.; Roncarelli, M.; Rosati, P.; Quadrini, E.; Ruchayskiy, O.; Salvaterra, R.; Sasaki, S.; Sato, K.; Savaglio, S.; Schaye, J.; Sciortino, S.; Shaposhnikov, M.; Sharples, R.; Shinozaki, K.; Spiga, D.; Sunyaev, R.; Suto, Y.; Takei, Y.; Tanvir, N.; Tashiro, M.; Tamura, T.; Tawara, Y.; Troja, E.; Tsujimoto, M.; Tsuru, T.; Ubertini, P.; Ullom, J.; Ursino, E.; Verbunt, F.; van de Voort, F.; Viel, M.; Wachter, S.; Watson, D.; Weisskopf, M.; Werner, N.; White, N.; Willingale, R.; Wijers, R.; Yamasaki, N.; Yoshikawa, K.; Zane, S.

    2011-01-01

    ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of metal creation from the epoch of cosmic dawn. Using high-spectral resolution in the soft X-ray band, ORIGIN will be able to identify the physical conditions of all abundant elements between C and Ni to red-shifts of z=10, and beyond. The mission will answer questions such as: When were the first metals created? How does the cosmic metal content evolve? Where do most of the metals reside in the Universe? What is the role of metals in structure formation and evolution? To reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to study their local environments in their host galaxies. This requires the capability to slew the satellite in less than a minute to the GRB location. By studying the chemical composition and properties of clusters of galaxies we can extend the range of exploration to lower redshifts (z ~ 0.2). For this task we need a high-resolution spectral imaging instrument with a large field of view. Using the ...

  16. Hitting the nail on the head: Force vectors in verb semantics

    NARCIS (Netherlands)

    Goldschmidt, A.; Zwarts, J.

    2016-01-01

    We present an analysis of force verbs, like hit, as involving paths with force-dynamic properties, modelled through force vectors. This allows us to explain a number of observations about the lexical meaning and composition of these verbs. For instance, force adverbs such as hard specify the

  17. Simultaneous calibration phantom commission and geometry calibration in cone beam CT

    Science.gov (United States)

    Xu, Yuan; Yang, Shuai; Ma, Jianhui; Li, Bin; Wu, Shuyu; Qi, Hongliang; Zhou, Linghong

    2017-09-01

    Geometry calibration is a vital step for describing the geometry of a cone beam computed tomography (CBCT) system and is a prerequisite for CBCT reconstruction. In current methods, calibration phantom commission and geometry calibration are divided into two independent tasks. Small errors in ball-bearing (BB) positioning in the phantom-making step will severely degrade the quality of phantom calibration. To solve this problem, we propose an integrated method to simultaneously realize geometry phantom commission and geometry calibration. Instead of assuming the accuracy of the geometry phantom, the integrated method considers BB centers in the phantom as an optimized parameter in the workflow. Specifically, an evaluation phantom and the corresponding evaluation contrast index are used to evaluate geometry artifacts for optimizing the BB coordinates in the geometry phantom. After utilizing particle swarm optimization, the CBCT geometry and BB coordinates in the geometry phantom are calibrated accurately and are then directly used for the next geometry calibration task in other CBCT systems. To evaluate the proposed method, both qualitative and quantitative studies were performed on simulated and realistic CBCT data. The spatial resolution of reconstructed images using dental CBCT can reach up to 15 line pair cm-1. The proposed method is also superior to the Wiesent method in experiments. This paper shows that the proposed method is attractive for simultaneous and accurate geometry phantom commission and geometry calibration.

  18. THEORY OF ACTIVE HITTINGS IS IN PROCESSES OF ELECTRO-COAGULATION THE ADMIXTURES IN WATER TECHNOLOGICAL ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    В.В. Березуцький

    2012-10-01

    Full Text Available  In the article theoretical bases of electro-coagulation of admixtures are examined in a water technological environment with the use of theory of the active hittings, which are based on the results of the executed researches and analysis of scientific information. Application of theory of the active hittings is in coagulation, provides high efficiency of process of extraction of admixtures from water environments during minimization of energy consumption and expenses of materials.

  19. SPRT Calibration Uncertainties and Internal Quality Control at a Commercial SPRT Calibration Facility

    Science.gov (United States)

    Wiandt, T. J.

    2008-06-01

    The Hart Scientific Division of the Fluke Corporation operates two accredited standard platinum resistance thermometer (SPRT) calibration facilities, one at the Hart Scientific factory in Utah, USA, and the other at a service facility in Norwich, UK. The US facility is accredited through National Voluntary Laboratory Accreditation Program (NVLAP), and the UK facility is accredited through UKAS. Both provide SPRT calibrations using similar equipment and procedures, and at similar levels of uncertainty. These uncertainties are among the lowest available commercially. To achieve and maintain low uncertainties, it is required that the calibration procedures be thorough and optimized. However, to minimize customer downtime, it is also important that the instruments be calibrated in a timely manner and returned to the customer. Consequently, subjecting the instrument to repeated calibrations or extensive repeated measurements is not a viable approach. Additionally, these laboratories provide SPRT calibration services involving a wide variety of SPRT designs. These designs behave differently, yet predictably, when subjected to calibration measurements. To this end, an evaluation strategy involving both statistical process control and internal consistency measures is utilized to provide confidence in both the instrument calibration and the calibration process. This article describes the calibration facilities, procedure, uncertainty analysis, and internal quality assurance measures employed in the calibration of SPRTs. Data will be reviewed and generalities will be presented. Finally, challenges and considerations for future improvements will be discussed.

  20. Capture orbits around asteroids by hitting zero-velocity curves

    Science.gov (United States)

    Wang, Wei; Yang, Hongwei; Zhang, Wei; Ma, Guangfu

    2017-12-01

    The problem of capturing a spacecraft from a heliocentric orbit into a high parking orbit around binary asteroids is investigated in the current study. To reduce the braking Δ V, a new capture strategy takes advantage of the three-body gravity of the binary asteroid to lower the inertial energy before applying the Δ V. The framework of the circular restricted three-body problem (CR3BP) is employed for the binary asteroid system. The proposed capture strategy is based on the mechanism by which inertial energy can be decreased sharply near zero-velocity curves (ZVCs). The strategy has two steps, namely, hitting the target ZVC and raising the periapsis by a small Δ V at the apoapsis. By hitting the target ZVC, the positive inertial energy decreases and becomes negative. Using a small Δ V, the spacecraft inserts into a bounded orbit around the asteroid. In addition, a rotating mass dipole model is employed for elongated asteroids, which leads to dynamics similar to that of the CR3BP. With this approach, the proposed capture strategy can be applied to elongated asteroids. Numerical simulations validate that the proposed capture strategy is applicable for the binary asteroid 90 Antiope and the elongated asteroid 216 Kleopatra.

  1. Calibration and intercomparison methods of dose calibrators used in nuclear medicine facilities

    International Nuclear Information System (INIS)

    Costa, Alessandro Martins da

    1999-01-01

    Dose calibrators are used in most of the nuclear medicine facilities to determine the amount of radioactivity administered to a patient in a particular investigation or therapeutic procedure. It is therefore of vital importance that the equipment used presents good performance and is regular;y calibrated at a authorized laboratory. This occurs of adequate quality assurance procedures are carried out. Such quality control tests should be performed daily, other biannually or yearly, testing, for example, its accuracy and precision, the reproducibility and response linearity. In this work a commercial dose calibrator was calibrated with solution of radionuclides used in nuclear medicine. Simple instrument tests, such as response linearity and the response variation of the source volume increase at a constant source activity concentration, were performed. This instrument can now be used as a working standard for calibration of other dose calibrators/ An intercomparison procedure was proposed as a method of quality control of dose calibrators used in nuclear medicine facilities. (author)

  2. "Hits" emerge through self-organized coordination in collective response of free agents

    Science.gov (United States)

    Chakrabarti, Anindya S.; Sinha, Sitabhra

    2016-10-01

    Individuals in free societies frequently exhibit striking coordination when making independent decisions en masse. Examples include the regular appearance of hit products or memes with substantially higher popularity compared to their otherwise equivalent competitors or extreme polarization in public opinion. Such segregation of events manifests as bimodality in the distribution of collective choices. Here we quantify how apparently independent choices made by individuals result in a significantly polarized but stable distribution of success in the context of the box-office performance of movies and show that it is an emergent feature of a system of noninteracting agents who respond to sequentially arriving signals. The aggregate response exhibits extreme variability amplifying much smaller differences in individual cost of adoption. Due to self-organization of the competitive landscape, most events elicit only a muted response but a few stimulate widespread adoption, emerging as "hits".

  3. Technologies for Low Frequency Radio Observations of the Cosmic Dawn

    Science.gov (United States)

    Jones, Dayton L.

    2014-01-01

    The Jet Propulsion Laboratory (JPL) is developing concepts and technologies for low frequency radio astronomy space missions aimed at observing highly redshifted neutral Hydrogen from the Dark Ages. This is the period of cosmic history between the recombination epoch when the microwave background radiation was produced and the re-ionization of the intergalactic medium by the first generation of stars (Cosmic Dawn). This period, at redshifts greater than about 20, is a critical epoch for the formation and evolution of large-scale structure in the universe. The 21-cm spectral line of Hydrogen provides the most promising method for directly studying the Dark Ages, but the corresponding frequencies at such large redshifts are only tens of MHz and thus require space-based observations to avoid terrestrial RFI and ionospheric absorption and refraction. This paper reports on the status of several low frequency technology development activities at JPL, including deployable bi-conical dipoles for a planned lunar-orbiting mission, and both rover-deployed and inflation-deployed long dipole antennas for use on the lunar surface.

  4. Mechanics of log calibration

    International Nuclear Information System (INIS)

    Waller, W.C.; Cram, M.E.; Hall, J.E.

    1975-01-01

    For any measurement to have meaning, it must be related to generally accepted standard units by a valid and specified system of comparison. To calibrate well-logging tools, sensing systems are designed which produce consistent and repeatable indications over the range for which the tool was intended. The basics of calibration theory, procedures, and calibration record presentations are reviewed. Calibrations for induction, electrical, radioactivity, and sonic logging tools will be discussed. The authors' intent is to provide an understanding of the sources of errors, of the way errors are minimized in the calibration process, and of the significance of changes in recorded calibration data

  5. Sleeping beauties in psychology: comparisons of "hits" and "missed signals" in psychological journals.

    Science.gov (United States)

    Lange, Lydia L

    2005-05-01

    Scientific publications tend to be forgotten quickly. A few works, however, are still cited 100 years and more after their publication. The author used bibliometric methods to compare "hits" (works noticed by the scientific community soon after their publication) with "missed signals" (works that went unnoticed until much later) by investigating 2 psychological journals founded in the 1890s: Zeitschrift für Psychologie and Psychological Review. All articles that were published in either of these journals up to 1920 and cited more than 25 times in the Web of Science up to the year 2000 were considered for inclusion in the analysis. It emerged that hits corresponded more closely to the focus of scientific attention at the time of the publications than missed signals.

  6. Development and Calibration of a Model for the Determination of Hurricane Wind Speed Field at the Peninsula of Yucatan

    Directory of Open Access Journals (Sweden)

    L.E. Fernández–Baqueiro

    2009-01-01

    Full Text Available In this work a model to calculate the wind speed field produced by hurricanes that hit the Yucatan Peninsula is developed. The model variables are calculated using equations recently developed, that include new advances in meteorology. The steps in the model are described and implemented in a computer program to systematize and facilitate the use of this model. The model and the program are calibrated using two data bases; the first one includes trajectories and maximum wind velocities of hurricanes; the second one includes records of wind velocities obtained from the Automatic Meteorology Stations of the National Meteorology Service. The hurricane wind velocity field is calculated using the model and information of the first data base. The model results are compared with field data from the second data base. The model is calibrated adjusting the Holland's pressure radial profile parameter B; this is carried out for three hurricane records: Isidore, Emily and Wilma. It is concluded that a value of B of 1.3 adjusts globally the three hurricane records and that the developed model is capable of reproducing satisfactorily the wind velocity records.

  7. Antiproton annihilation physics annihilation physics in the Monte Carlo particle transport code particle transport code SHIELD-HIT12A

    DEFF Research Database (Denmark)

    Taasti, Vicki Trier; Knudsen, Helge; Holzscheiter, Michael

    2015-01-01

    The Monte Carlo particle transport code SHIELD-HIT12A is designed to simulate therapeutic beams for cancer radiotherapy with fast ions. SHIELD-HIT12A allows creation of antiproton beam kernels for the treatment planning system TRiP98, but first it must be benchmarked against experimental data. An...

  8. Scanner calibration revisited

    Directory of Open Access Journals (Sweden)

    Pozhitkov Alexander E

    2010-07-01

    Full Text Available Abstract Background Calibration of a microarray scanner is critical for accurate interpretation of microarray results. Shi et al. (BMC Bioinformatics, 2005, 6, Art. No. S11 Suppl. 2. reported usage of a Full Moon BioSystems slide for calibration. Inspired by the Shi et al. work, we have calibrated microarray scanners in our previous research. We were puzzled however, that most of the signal intensities from a biological sample fell below the sensitivity threshold level determined by the calibration slide. This conundrum led us to re-investigate the quality of calibration provided by the Full Moon BioSystems slide as well as the accuracy of the analysis performed by Shi et al. Methods Signal intensities were recorded on three different microarray scanners at various photomultiplier gain levels using the same calibration slide from Full Moon BioSystems. Data analysis was conducted on raw signal intensities without normalization or transformation of any kind. Weighted least-squares method was used to fit the data. Results We found that initial analysis performed by Shi et al. did not take into account autofluorescence of the Full Moon BioSystems slide, which led to a grossly distorted microarray scanner response. Our analysis revealed that a power-law function, which is explicitly accounting for the slide autofluorescence, perfectly described a relationship between signal intensities and fluorophore quantities. Conclusions Microarray scanners respond in a much less distorted fashion than was reported by Shi et al. Full Moon BioSystems calibration slides are inadequate for performing calibration. We recommend against using these slides.

  9. Concurrent inhibition of MYC and BCL2 is a potentially effective treatment strategy for double hit and triple hit B-cell lymphomas.

    Science.gov (United States)

    Cinar, Munevver; Rosenfelt, Fred; Rokhsar, Sepehr; Lopategui, Jean; Pillai, Raju; Cervania, Melissa; Pao, Andy; Cinar, Bekir; Alkan, Serhan

    2015-07-01

    Double hit lymphoma or triple hit lymphoma (DHL/THL) is a rare form of aggressive B-Cell Lymphoma. Overexpression of MYC, BCL2 or/and BCL6 due to genomic rearrangements are the key molecular features of DHL/THL. Patients with DHL/THL show very aggressive disease course and poor survival due to the lack of effective treatment modalities. Here, we established new THL cell model and assessed its in vitro growth characteristics along with the DHL cell line in response to potent MYC inhibitors, 10058-F4 and JQ-1, and a BCL2 inhibitor, ABT-199, with or without chemotherapeutic agent vincristine or doxorubicin. We found that 10058-F4, JQ-1 or ABT-199 exposure as a single agent inhibited the growth of DHL/THL cells in a dose-dependent manner. Combined exposure of 10058-F4 or JQ-1 and ABT-199 as well as vincristine or doxorubicin markedly suppressed the growth of DHL/THL cells compared with the single treatment. As assessed by multiple approaches, apoptosis induced by ABT-199, 10058-F4 or JQ-1 was underlying cause of the observed growth suppression. These findings suggest that co-inhibition of MYC and BCL2 signaling is a promising therapeutic strategy for patients with DHL/THL lymphomas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. HitPredict version 4: comprehensive reliability scoring of physical protein-protein interactions from more than 100 species.

    Science.gov (United States)

    López, Yosvany; Nakai, Kenta; Patil, Ashwini

    2015-01-01

    HitPredict is a consolidated resource of experimentally identified, physical protein-protein interactions with confidence scores to indicate their reliability. The study of genes and their inter-relationships using methods such as network and pathway analysis requires high quality protein-protein interaction information. Extracting reliable interactions from most of the existing databases is challenging because they either contain only a subset of the available interactions, or a mixture of physical, genetic and predicted interactions. Automated integration of interactions is further complicated by varying levels of accuracy of database content and lack of adherence to standard formats. To address these issues, the latest version of HitPredict provides a manually curated dataset of 398 696 physical associations between 70 808 proteins from 105 species. Manual confirmation was used to resolve all issues encountered during data integration. For improved reliability assessment, this version combines a new score derived from the experimental information of the interactions with the original score based on the features of the interacting proteins. The combined interaction score performs better than either of the individual scores in HitPredict as well as the reliability score of another similar database. HitPredict provides a web interface to search proteins and visualize their interactions, and the data can be downloaded for offline analysis. Data usability has been enhanced by mapping protein identifiers across multiple reference databases. Thus, the latest version of HitPredict provides a significantly larger, more reliable and usable dataset of protein-protein interactions from several species for the study of gene groups. Database URL: http://hintdb.hgc.jp/htp. © The Author(s) 2015. Published by Oxford University Press.

  11. A New Track Reconstruction Algorithm suitable for Parallel Processing based on Hit Triplets and Broken Lines

    Directory of Open Access Journals (Sweden)

    Schöning André

    2016-01-01

    Full Text Available Track reconstruction in high track multiplicity environments at current and future high rate particle physics experiments is a big challenge and very time consuming. The search for track seeds and the fitting of track candidates are usually the most time consuming steps in the track reconstruction. Here, a new and fast track reconstruction method based on hit triplets is proposed which exploits a three-dimensional fit model including multiple scattering and hit uncertainties from the very start, including the search for track seeds. The hit triplet based reconstruction method assumes a homogeneous magnetic field which allows to give an analytical solutions for the triplet fit result. This method is highly parallelizable, needs fewer operations than other standard track reconstruction methods and is therefore ideal for the implementation on parallel computing architectures. The proposed track reconstruction algorithm has been studied in the context of the Mu3e-experiment and a typical LHC experiment.

  12. Efficiency profile method to study the hit efficiency of drift chambers

    International Nuclear Information System (INIS)

    Abyzov, A.; Bel'kov, A.; Lanev, A.; Spiridonov, A.; Walter, M.; Hulsbergen, W.

    2002-01-01

    A method based on the usage of efficiency profile is proposed to estimate the hit efficiency of drift chambers with a large number of channels. The performance of the method under real conditions of the detector operation has been tested analysing the experimental data from the HERA-B drift chambers

  13. Simulation of a Real-Time Brain Computer Interface for Detecting a Self-Paced Hitting Task.

    Science.gov (United States)

    Hammad, Sofyan H; Kamavuako, Ernest N; Farina, Dario; Jensen, Winnie

    2016-12-01

    An invasive brain-computer interface (BCI) is a promising neurorehabilitation device for severely disabled patients. Although some systems have been shown to work well in restricted laboratory settings, their utility must be tested in less controlled, real-time environments. Our objective was to investigate whether a specific motor task could be reliably detected from multiunit intracortical signals from freely moving animals in a simulated, real-time setting. Intracortical signals were first obtained from electrodes placed in the primary motor cortex of four rats that were trained to hit a retractable paddle (defined as a "Hit"). In the simulated real-time setting, the signal-to-noise-ratio was first increased by wavelet denoising. Action potentials were detected, and features were extracted (spike count, mean absolute values, entropy, and combination of these features) within pre-defined time windows (200 ms, 300 ms, and 400 ms) to classify the occurrence of a "Hit." We found higher detection accuracy of a "Hit" (73.1%, 73.4%, and 67.9% for the three window sizes, respectively) when the decision was made based on a combination of features rather than on a single feature. However, the duration of the window length was not statistically significant (p = 0.5). Our results showed the feasibility of detecting a motor task in real time in a less restricted environment compared to environments commonly applied within invasive BCI research, and they showed the feasibility of using information extracted from multiunit recordings, thereby avoiding the time-consuming and complex task of extracting and sorting single units. © 2016 International Neuromodulation Society.

  14. EASY-HIT: HIV full-replication technology for broad discovery of multiple classes of HIV inhibitors.

    Science.gov (United States)

    Kremb, Stephan; Helfer, Markus; Heller, Werner; Hoffmann, Dieter; Wolff, Horst; Kleinschmidt, Andrea; Cepok, Sabine; Hemmer, Bernhard; Durner, Jörg; Brack-Werner, Ruth

    2010-12-01

    HIV replication assays are important tools for HIV drug discovery efforts. Here, we present a full HIV replication system (EASY-HIT) for the identification and analysis of HIV inhibitors. This technology is based on adherently growing HIV-susceptible cells, with a stable fluorescent reporter gene activated by HIV Tat and Rev. A fluorescence-based assay was designed that measures HIV infection by two parameters relating to the early and the late phases of HIV replication, respectively. Validation of the assay with a panel of nine reference inhibitors yielded effective inhibitory concentrations consistent with published data and allowed discrimination between inhibitors of early and late phases of HIV replication. Finer resolution of the effects of reference drugs on different steps of HIV replication was achieved in secondary time-of-addition assays. The EASY-HIT assay yielded high Z' scores (>0.9) and signal stabilities, confirming its robustness. Screening of the LOPAC(1280) library identified 10 compounds (0.8%), of which eight were known to inhibit HIV, validating the suitability of this assay for screening applications. Studies evaluating anti-HIV activities of natural products with the EASY-HIT technology led to the identification of three novel inhibitory compounds that apparently act at different steps of HIV-1 replication. Furthermore, we demonstrate successful evaluation of plant extracts for HIV-inhibitory activities, suggesting application of this technology for the surveillance of biological extracts with anti-HIV activities. We conclude that the EASY-HIT technology is a versatile tool for the discovery and characterization of HIV inhibitors.

  15. Antimicrobial combinations: Bliss independence and Loewe additivity derived from mechanistic multi-hit models

    Science.gov (United States)

    Yu, Guozhi; Hozé, Nathanaël; Rolff, Jens

    2016-01-01

    Antimicrobial peptides (AMPs) and antibiotics reduce the net growth rate of bacterial populations they target. It is relevant to understand if effects of multiple antimicrobials are synergistic or antagonistic, in particular for AMP responses, because naturally occurring responses involve multiple AMPs. There are several competing proposals describing how multiple types of antimicrobials add up when applied in combination, such as Loewe additivity or Bliss independence. These additivity terms are defined ad hoc from abstract principles explaining the supposed interaction between the antimicrobials. Here, we link these ad hoc combination terms to a mathematical model that represents the dynamics of antimicrobial molecules hitting targets on bacterial cells. In this multi-hit model, bacteria are killed when a certain number of targets are hit by antimicrobials. Using this bottom-up approach reveals that Bliss independence should be the model of choice if no interaction between antimicrobial molecules is expected. Loewe additivity, on the other hand, describes scenarios in which antimicrobials affect the same components of the cell, i.e. are not acting independently. While our approach idealizes the dynamics of antimicrobials, it provides a conceptual underpinning of the additivity terms. The choice of the additivity term is essential to determine synergy or antagonism of antimicrobials. This article is part of the themed issue ‘Evolutionary ecology of arthropod antimicrobial peptides’. PMID:27160596

  16. Antimicrobial combinations: Bliss independence and Loewe additivity derived from mechanistic multi-hit models.

    Science.gov (United States)

    Baeder, Desiree Y; Yu, Guozhi; Hozé, Nathanaël; Rolff, Jens; Regoes, Roland R

    2016-05-26

    Antimicrobial peptides (AMPs) and antibiotics reduce the net growth rate of bacterial populations they target. It is relevant to understand if effects of multiple antimicrobials are synergistic or antagonistic, in particular for AMP responses, because naturally occurring responses involve multiple AMPs. There are several competing proposals describing how multiple types of antimicrobials add up when applied in combination, such as Loewe additivity or Bliss independence. These additivity terms are defined ad hoc from abstract principles explaining the supposed interaction between the antimicrobials. Here, we link these ad hoc combination terms to a mathematical model that represents the dynamics of antimicrobial molecules hitting targets on bacterial cells. In this multi-hit model, bacteria are killed when a certain number of targets are hit by antimicrobials. Using this bottom-up approach reveals that Bliss independence should be the model of choice if no interaction between antimicrobial molecules is expected. Loewe additivity, on the other hand, describes scenarios in which antimicrobials affect the same components of the cell, i.e. are not acting independently. While our approach idealizes the dynamics of antimicrobials, it provides a conceptual underpinning of the additivity terms. The choice of the additivity term is essential to determine synergy or antagonism of antimicrobials.This article is part of the themed issue 'Evolutionary ecology of arthropod antimicrobial peptides'. © 2016 The Author(s).

  17. A review of vulnerability and risks for schizophrenia: Beyond the two hit hypothesis

    Science.gov (United States)

    Davis, Justin; Eyre, Harris; Jacka, Felice N; Dodd, Seetal; Dean, Olivia; McEwen, Sarah; Debnath, Monojit; McGrath, John; Maes, Michael; Amminger, Paul; McGorry, Patrick D; Pantelis, Christos; Berk, Michael

    2016-01-01

    Schizophrenia risk has often been conceptualized using a model which requires two hits in order to generate the clinical phenotype—the first as an early priming in a genetically predisposed individual and the second a likely environmental insult. The aim of this paper was to review the literature and reformulate this binary risk-vulnerability model. We sourced the data for this narrative review from the electronic database PUBMED. Our search terms were not limited by language or date of publication. The development of schizophrenia may be driven by genetic vulnerability interacting with multiple vulnerability factors including lowered prenatal vitamin D exposure, viral infections, smoking intelligence quotient, social cognition cannabis use, social defeat, nutrition and childhood trauma. It is likely that these genetic risks, environmental risks and vulnerability factors are cumulative and interactive with each other and with critical periods of neurodevelopmental vulnerability. The development of schizophrenia is likely to be more complex and nuanced than the binary two hit model originally proposed nearly thirty years ago. Risk appears influenced by a more complex process involving genetic risk interfacing with multiple potentially interacting hits and vulnerability factors occurring at key periods of neurodevelopmental activity, which culminate in the expression of disease state. These risks are common across a number of neuropsychiatric and medical disorders, which might inform common preventive and intervention strategies across non-communicable disorders. PMID:27073049

  18. Adiabatic condition and the quantum hitting time of Markov chains

    International Nuclear Information System (INIS)

    Krovi, Hari; Ozols, Maris; Roland, Jeremie

    2010-01-01

    We present an adiabatic quantum algorithm for the abstract problem of searching marked vertices in a graph, or spatial search. Given a random walk (or Markov chain) P on a graph with a set of unknown marked vertices, one can define a related absorbing walk P ' where outgoing transitions from marked vertices are replaced by self-loops. We build a Hamiltonian H(s) from the interpolated Markov chain P(s)=(1-s)P+sP ' and use it in an adiabatic quantum algorithm to drive an initial superposition over all vertices to a superposition over marked vertices. The adiabatic condition implies that, for any reversible Markov chain and any set of marked vertices, the running time of the adiabatic algorithm is given by the square root of the classical hitting time. This algorithm therefore demonstrates a novel connection between the adiabatic condition and the classical notion of hitting time of a random walk. It also significantly extends the scope of previous quantum algorithms for this problem, which could only obtain a full quadratic speedup for state-transitive reversible Markov chains with a unique marked vertex.

  19. Absolute radiometric calibration of Landsat using a pseudo invariant calibration site

    Science.gov (United States)

    Helder, D.; Thome, K.J.; Mishra, N.; Chander, G.; Xiong, Xiaoxiong; Angal, A.; Choi, Tae-young

    2013-01-01

    Pseudo invariant calibration sites (PICS) have been used for on-orbit radiometric trending of optical satellite systems for more than 15 years. This approach to vicarious calibration has demonstrated a high degree of reliability and repeatability at the level of 1-3% depending on the site, spectral channel, and imaging geometries. A variety of sensors have used this approach for trending because it is broadly applicable and easy to implement. Models to describe the surface reflectance properties, as well as the intervening atmosphere have also been developed to improve the precision of the method. However, one limiting factor of using PICS is that an absolute calibration capability has not yet been fully developed. Because of this, PICS are primarily limited to providing only long term trending information for individual sensors or cross-calibration opportunities between two sensors. This paper builds an argument that PICS can be used more extensively for absolute calibration. To illustrate this, a simple empirical model is developed for the well-known Libya 4 PICS based on observations by Terra MODIS and EO-1 Hyperion. The model is validated by comparing model predicted top-of-atmosphere reflectance values to actual measurements made by the Landsat ETM+ sensor reflective bands. Following this, an outline is presented to develop a more comprehensive and accurate PICS absolute calibration model that can be Système international d'unités (SI) traceable. These initial concepts suggest that absolute calibration using PICS is possible on a broad scale and can lead to improved on-orbit calibration capabilities for optical satellite sensors.

  20. "The Voyage of the Dawn Treader": The World at the Dawn of 2006-2011. Understanding societal themes

    Directory of Open Access Journals (Sweden)

    Sanchen Henning

    2014-01-01

    Full Text Available This article offers a snapshot of the societal dynamics of individual countries around the world, integrated into a global view to provide the tourism and hospitality industry insight into potential customer needs and perceptions. The OPUS Reports on the Global Dynamics at the Dawn of 20...are published annually since 2006 in the Journal of Organisational and Social Dynamics in London. The researchers were interested in a metaphoric tour of the world's social dynamics over time as perceived from both the Systems psychodynamics and Positive psychology theoretical paradigms. The research methodology was qualitative using a case study approach where each of the six (2006- 2011 years' integrated hypotheses was studied as a separate case study. The six cases were integrated into new hypotheses reflecting how global social dynamics changed over the years. The findings were presented as hypotheses per individual country followed by an integrated global hypothesis. The three main emerging themes were framed as Identity, Hope and Love. Identity contains the sub-theme of Facelessness, described as the fragmentation of cultures, a loss of cultural identity and a search for shared social meaning. Hope embodies the theme Knight/s in shining armour which describes youth as saviours and Obama as saviour. The loss of Hope is illustrated by the sub-themes of the impotence of the older generation, pessimism, fear and the death of a way of life. Love consists of human connection described as affiliation, support and trust. The lack of Love consists of human alienation described as loneliness, aggression and violence. The findings of the study identify societal themes that can be operationalized in the tourism and hospitality industry through targeted offerings to provide in the unmet needs of society. In addition, training interventions to improve customer service and return on investment can be based on the findings of this research.

  1. Hitting the nail on the head: Force vectors in verb semantics

    NARCIS (Netherlands)

    Goldschmidt, A.; Zwarts, J.

    2016-01-01

    Hitting the nail on the head: Forces in verb meanings Anja Goldschmidt (UU) & Joost Zwarts (UU) There is a growing recognition of the role of forces in verb meanings, starting with the seminal work of Leonard Talmy (Talmy 1985). In one line of research these forces are analyzed in terms of vectors,

  2. MIMOSA-26 calibration and noise measurement based on the digital sensor output

    Energy Technology Data Exchange (ETDEWEB)

    Milanovic, Borislav [Goethe Uni Frankfurt (Germany); Collaboration: CBM-MVD-Collaboration

    2014-07-01

    CMOS Monolithic Active Pixel Sensors (MAPS) are used for high-precision tracking in particle detectors. They are applied for the STAR detector and also considered for the future CBM and ALICE experiments. MAPS combine high detection efficiency (> 99 %), with ultra-low material budget (thinned to 50 μm) and low power consumption (ca. 250 mW/cm{sup 2}). Their main feature is an integrated digital readout circuit situated directly on-chip. MIMOSA-26, developed at the IPHC Strasbourg, represents the basis of a modern MAPS. The sensor allows programming and slow control via JTAG. Sensitivity to impinging particles can be easily modified by changing the internal JTAG registers. However, the sensors require a careful tuning of run-time parameters, e.g. thresholds for the on-chip discriminators to guarantee a high detection efficiency and a low fake hit occupancy, i,e, electronic noise. This contribution presents a systematic study of the sensor/pixel response to noise allowing for a sensor characterization, calibration and selection prior to integration.

  3. Prenatal cannabis exposure - The "first hit" to the endocannabinoid system.

    Science.gov (United States)

    Richardson, Kimberlei A; Hester, Allison K; McLemore, Gabrielle L

    As more states and countries legalize medical and/or adult recreational marijuana use, the incidences of prenatal cannabis exposure (PCE) will likely increase. While young people increasingly view marijuana as innocuous, marijuana preparations have been growing in potency in recent years, potentially creating global clinical, public health, and workforce concerns. Unlike fetal alcohol spectrum disorder, there is no phenotypic syndrome associated with PCE. There is also no preponderance of evidence that PCE causes lifelong cognitive, behavioral, or functional abnormalities, and/or susceptibility to subsequent addiction. However, there is compelling circumstantial evidence, based on the principles of teratology and fetal malprogramming, suggesting that pregnant women should refrain from smoking marijuana. The usage of marijuana during pregnancy perturbs the fetal endogenous cannabinoid signaling system (ECSS), which is present and active from the early embryonic stage, modulating neurodevelopment and continuing this role into adulthood. The ECSS is present in virtually every brain structure and organ system, and there is also evidence that this system is important in the regulation of cardiovascular processes. Endocannabinoids (eCBs) undergird a broad spectrum of processes, including the early stages of fetal neurodevelopment and uterine implantation. Delta-9-tetrahydrocannabinol (THC), the psychoactive chemical in cannabis, enters maternal circulation, and readily crosses the placental membrane. THC binds to CB receptors of the fetal ECSS, altering neurodevelopment and possibly rewiring ECSS circuitry. In this review, we discuss the Double-Hit Hypothesis as it relates to PCE. We contend that PCE, similar to a neurodevelopmental teratogen, delivers the first hit to the ECSS, which is compromised in such a way that a second hit (i.e., postnatal stressors) will precipitate the emergence of a specific phenotype. In summary, we conclude that perturbations of the

  4. mobile Digital Access to a Web-enhanced Network (mDAWN): Assessing the Feasibility of Mobile Health Tools for Self-Management of Type-2 Diabetes.

    Science.gov (United States)

    Ho, Kendall; Newton, Lana; Boothe, Allison; Novak-Lauscher, Helen

    2015-01-01

    The mobile Digital Access to a Web-enhanced Network (mDAWN) program was implemented as an online, mobile self-management system to support patients with type-2 diabetes and their informal caregivers. Patients used wireless physiological sensors, received text messages, and had access to a secure web platform with health resources and semi-facilitated discussion forum. Outcomes were evaluated using (1) pre and post self-reported health behavior measures, (2) physiological outcomes, (3) program cost, and (4) in-depth participant interviews. The group had significantly decreased health distress, HbA1c levels, and systolic blood pressure. Participants largely saw the mDAWN as providing good value for the costs involved and found the program to be empowering in gaining control over their diabetes. mHealth programs have the potential to improve clinical outcomes through cost effective patient-led care for chronic illness. Further evaluation needs to examine integration of similar mHealth programs into the patient-physician relationship.

  5. Calibration-on-the-spot”: How to calibrate an EMCCD camera from its images

    DEFF Research Database (Denmark)

    Mortensen, Kim; Flyvbjerg, Henrik

    2016-01-01

    In order to count photons with a camera, the camera must be calibrated. Photon counting is necessary, e.g., to determine the precision of localization-based super-resolution microscopy. Here we present a protocol that calibrates an EMCCD camera from information contained in isolated, diffraction-......-limited spots in any image taken by the camera, thus making dedicated calibration procedures redundant by enabling calibration post festum, from images filed without calibration information....

  6. Contribution of Visual Information about Ball Trajectory to Baseball Hitting Accuracy.

    Directory of Open Access Journals (Sweden)

    Takatoshi Higuchi

    Full Text Available The contribution of visual information about a pitched ball to the accuracy of baseball-bat contact may vary depending on the part of trajectory seen. The purpose of the present study was to examine the relationship between hitting accuracy and the segment of the trajectory of the flying ball that can be seen by the batter. Ten college baseball field players participated in the study. The systematic error and standardized variability of ball-bat contact on the bat coordinate system and pitcher-to-catcher direction when hitting a ball launched from a pitching machine were measured with or without visual occlusion and analyzed using analysis of variance. The visual occlusion timing included occlusion from 150 milliseconds (ms after the ball release (R+150, occlusion from 150 ms before the expected arrival of the launched ball at the home plate (A-150, and a condition with no occlusion (NO. Twelve trials in each condition were performed using two ball speeds (31.9 m·s-1 and 40.3 m·s-1. Visual occlusion did not affect the mean location of ball-bat contact in the bat's long axis, short axis, and pitcher-to-catcher directions. Although the magnitude of standardized variability was significantly smaller in the bat's short axis direction than in the bat's long axis and pitcher-to-catcher directions (p < 0.001, additional visible time from the R+150 condition to the A-150 and NO conditions resulted in a further decrease in standardized variability only in the bat's short axis direction (p < 0.05. The results suggested that there is directional specificity in the magnitude of standardized variability with different visible time. The present study also confirmed the limitation to visual information is the later part of the ball trajectory for improving hitting accuracy, which is likely due to visuo-motor delay.

  7. As the Economic Crisis Hits Home, Colleges Seek Help from Congress

    Science.gov (United States)

    Field, Kelly

    2008-01-01

    Congress is crafting a second economic-stimulus bill, and the nation's colleges, hit by the deepening fiscal crisis, want a share of the money. Over the last few weeks, colleges and their lobbyists have bombarded members of Congress with letters and phone calls seeking money for research, student aid, and infrastructure. However, Congress is…

  8. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters

    International Nuclear Information System (INIS)

    Hetland, Per O.; Friberg, Eva G.; Oevreboe, Kirsti M.; Bjerke, Hans H.

    2009-01-01

    In the summer of 2007 the secondary standard dosimetry laboratory (SSDL) in Norway established a calibration service for reference air-kerma product meter (KAP-meter). The air-kerma area product, PKA, is a dosimetric quantity that can be directly related to the patient dose and used for risk assessment associated with different x-ray examinations. The calibration of reference KAP-meters at the SSDL gives important information on parameters influencing the calibration factor for different types of KAP-meters. The use of reference KAP-meters calibrated at the SSDL is an easy and reliable way to calibrate or verify the PKA indicated by the x-ray equipment out in the clinics. Material and methods. Twelve KAP-meters were calibrated at the SSDL by use of the substitution method at five diagnostic radiation qualities (RQRs). Results. The calibration factors varied from 0.94 to 1.18. The energy response of the individual KAP-meters varied by a total of 20% between the different RQRs and the typical chamber transmission factors ranged from 0.78 to 0.91. Discussion. It is important to use a calibrated reference KAP-meter and a harmonised calibration method in the PKA calibration in hospitals. The obtained uncertainty in the PKA readings is comparable with other calibration methods if the information in the calibration certificate is correct used, corrections are made and proper positioning of the KAP-chamber is performed. This will ensure a reliable estimate of the patient dose and a proper optimisation of conventional x-ray examinations and interventional procedures

  9. Protective effects of Lagerstroemia speciosa on 3-morpholinosydnonimine (SIN-1)-induced oxidative stress in HIT-T15 pancreatic β cells.

    Science.gov (United States)

    Song, Jia-Le; Zhao, Xin; Wang, Qiang; Zhang, Ting

    2013-05-01

    Reactive oxygen species (ROS)-induced pancreatic β cell death affects insulin secretion and is important in the pathogenesis of diabetes. Lagerstroemia speciosa, a traditional folk medicine, has been used for t he prevention and treatment of diabetes. However, whether Lagerstroemia speciosa has a cytoprotective effect on pancreatic β cells remains to be elucidated. The present study aimed to investigate the cytoprotective effects of hot water extracts from Lagerstroemia speciosa leaves (LWE) on 3-morpholinosydnonimine (SIN-1)-induced oxidative damage in Syrian hamster pancreatic insulinoma HIT-T15 cells. The HIT-T15 cells were first treated with SIN-1 (50 µM) for 24 h and then co-incubated with LWE for 48 h. SIN-1 significantly decreased HIT-T15 cell viability (PHIT-T15 cells in a dose‑dependent manner. To further investigate the protective effects of LWE on SIN-1‑induced oxidative stress in HIT-T15 cells, the cellular levels of ROS, lipid peroxidation and endogenous antioxidant enzymes, including superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GSH-px), were determined. LWE decreased the intracellular levels of ROS and lipid peroxidation, and increased the activities of antioxidant enzymes. These results suggest that LWE has a cytoprotective effect against SIN-1‑induced oxidative stress in HIT-T15 cells through the inhibition of lipid peroxidation, a decrease in ROS levels and an increase in antioxidant enzyme activity. In addition, LWE increased insulin secretion in SIN-1-treated HIT-T15 cells. Our results suggested that LWE were effective in the treatment of diabetes. Further studies are required to study the anti-diabetic molecular mechanism in a cell model.

  10. Hit discovery of 4-amino-N-(4-(3-(trifluoromethyl)phenoxy)pyrimidin-5-yl)benzamide: A novel EGFR inhibitor from a designed small library.

    Science.gov (United States)

    Elkamhawy, Ahmed; Paik, Sora; Hassan, Ahmed H E; Lee, Yong Sup; Roh, Eun Joo

    2017-12-01

    Searching for hit compounds within the huge chemical space resembles the attempt to find a needle in a haystack. Cheminformatics-guided selection of few representative molecules of a rationally designed virtual combinatorial library is a powerful tool to confront this challenge, speed up hit identification and cut off costs. Herein, this approach has been applied to identify hit compounds with novel scaffolds able to inhibit EGFR kinase. From a generated virtual library, six 4-aryloxy-5-aminopyrimidine scaffold-derived compounds were selected, synthesized and evaluated as hit EGFR inhibitors. 4-Aryloxy-5-benzamidopyrimidines inhibited EGFR with IC 50 1.05-5.37 μM. Cell-based assay of the most potent EGFR inhibitor hit (10ac) confirmed its cytotoxicity against different cancerous cells. In spite of no EGFR, HER2 or VEGFR1 inhibition was elicited by 4-aryloxy-5-(thio)ureidopyrimidine derivatives, cell-based evaluation suggested them as antiproliferative hits acting by other mechanism(s). Molecular docking study provided a plausible explanation of incapability of 4-aryloxy-5-(thio)ureidopyrimidines to inhibit EGFR and suggested a reasonable binding mode of 4-aryloxy-5-benzamidopyrimidines which provides a basis to develop more optimized ligands. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Current drive experiments on the HIT-II spherical torus

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Raman, R.; Nelson, B.A.; Holcomb, C.T.; McCollam, K.J.; Sieck, P.E.

    1999-01-01

    This paper describes the following new achievements from the Helicity Injected Torus (HIT) program: a) formation and sustainment of a toroidal magnetic equilibrium using coaxial helicity injection (CHI) in a conducting shell that has an L/R time much shorter than the pulse length; b) static formation of a spherical torus with plasma current over 180 kA using a transformer and feedback controlled equilibrium coils; and c) production of a current increase in a transformer produced spherical torus using CHI. (author)

  12. Current drive experiments on the HIT-II spherical torus

    International Nuclear Information System (INIS)

    Jarboe, T.; Raman, R.; Nelson, B.; Holcomb, C.T.; McCollam, K.J.; Sieck, P.E.

    2001-01-01

    This paper describes the following new achievements from the Helicity Injected Torus (HIT) program: a) formation and sustainment of a toroidal magnetic equilibrium using coaxial helicity injection (CHI) in a conducting shell that has an L/R time much shorter than the pulse length; b) static formation of a spherical torus with plasma current over 180 kA using a transformer and feedback controlled equilibrium coils; and c) production of a current increase in a transformer produced spherical torus using CHI. (author)

  13. Demand spillovers of smash-hit papers: evidence from the 'Male Organ Incident'.

    Science.gov (United States)

    Kässi, Otto; Westling, Tatu

    2013-12-01

    This study explores the short-run spillover effects of popular research papers. We consider the publicity of 'Male Organ and Economic Growth: Does Size Matter?' as an exogenous shock to economics discussion paper demand, a natural experiment of a sort. In particular, we analyze how the very substantial visibility influenced the downloads of Helsinki Center of Economic Research discussion papers. Difference in differences and regression discontinuity analysis are conducted to elicit the spillover patterns. This study finds that the spillover effect to average economics paper demand is positive and statistically significant. It seems that hit papers increase the exposure of previously less downloaded papers. We find that part of the spillover effect could be attributable to Internet search engines' influence on browsing behavior. Conforming to expected patterns, papers residing on the same web page as the hit paper evidence very significant increases in downloads which also supports the spillover thesis. A11, C21. 97K80.

  14. Investigation on calibration parameter of mammography calibration facilities at MINT

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Wan Hazlinda Ismail; Md Saion Salikin; Muhammad Jamal Md Isa; Azuhar Ripin; Norriza Mohd Isa

    2004-01-01

    A mammography calibration facility has been established in the Medical Physics Laboratory, Malaysian Institute for Nuclear Technology Research (MINT). The calibration facility is established at the national level mainly to provide calibration services for radiation measuring test instruments or test tools used in quality assurance programme in mammography, which is being implemented in Malaysia. One of the accepted parameters that determine the quality of a radiation beam is the homogeneity coefficient. It is determined from the values of the 1 st and 2 nd Half Value Layer (HVL). In this paper, the consistency of the mammography machine beam qualities that is available in MINT, is investigated and presented. For calibration purposes, five radiation qualities namely 23, 25, 28, 30 and 35 kV, selectable from the control panel of the X-ray machine is used. Important parameters that are set for this calibration facility are exposure time, tube current, focal spot to detector distance (FDD) and beam size at specific distance. The values of homogeneity coefficient of this laboratory for the past few years tip to now be presented in this paper. Backscatter radiations are also considered in this investigation. (Author)

  15. A review of vulnerability and risks for schizophrenia: Beyond the two hit hypothesis.

    Science.gov (United States)

    Davis, Justin; Eyre, Harris; Jacka, Felice N; Dodd, Seetal; Dean, Olivia; McEwen, Sarah; Debnath, Monojit; McGrath, John; Maes, Michael; Amminger, Paul; McGorry, Patrick D; Pantelis, Christos; Berk, Michael

    2016-06-01

    Schizophrenia risk has often been conceptualized using a model which requires two hits in order to generate the clinical phenotype-the first as an early priming in a genetically predisposed individual and the second a likely environmental insult. The aim of this paper was to review the literature and reformulate this binary risk-vulnerability model. We sourced the data for this narrative review from the electronic database PUBMED. Our search terms were not limited by language or date of publication. The development of schizophrenia may be driven by genetic vulnerability interacting with multiple vulnerability factors including lowered prenatal vitamin D exposure, viral infections, smoking intelligence quotient, social cognition cannabis use, social defeat, nutrition and childhood trauma. It is likely that these genetic risks, environmental risks and vulnerability factors are cumulative and interactive with each other and with critical periods of neurodevelopmental vulnerability. The development of schizophrenia is likely to be more complex and nuanced than the binary two hit model originally proposed nearly thirty years ago. Risk appears influenced by a more complex process involving genetic risk interfacing with multiple potentially interacting hits and vulnerability factors occurring at key periods of neurodevelopmental activity, which culminate in the expression of disease state. These risks are common across a number of neuropsychiatric and medical disorders, which might inform common preventive and intervention strategies across non-communicable disorders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. A business case for HIT adoption: effects of "meaningful use" EHR financial incentives on clinic revenue.

    Science.gov (United States)

    Behkami, Nima A; Dorr, David A; Morrice, Stuart

    2010-01-01

    The goal of this study is to describe a framework that allows decision makers to efficiently evaluate factors that affect Electronic Health Record (EHR) adoption and test suitable interventions; specifically financial incentives. The United States healthcare delivery system is experiencing a transformation to improve population health. There is strong agreement that "meaningful use" of Health Information Technology (HIT) is a major enabler in this effort. However it's also understood that the high cost of implementing an EHR is an obstacle for adoption. To help understand these complexities we developed a simulation model designed to capture the dynamic nature of policy interventions that affect the adoption of EHR. We found that "Effective" use of HIT approaches break-even-point and larger clinic revenue many times faster that "average" or "poor" use of HIT. This study uses a systems perspective to the evaluate EHR adoption process through the "meaningful use" redesign as proposed in the American Reinvestment and Recovery Act 2009 in the United States healthcare industry by utilizing the System Dynamics methodology and Scenario Analysis.

  17. Influence of ITO deposition and post annealing on HIT solar cell structures

    NARCIS (Netherlands)

    Zhang, D.; Tavakoliyaraki, A.; Wu, Y.; Van Swaaij, R.A.C.M.M.; Zeman, M.

    2011-01-01

    Heterojunction silicon with intrinsic thin layer (HIT) solar cells that combine advanced thin-film hydrogenated amorphous silicon (a-Si:H) and crystalline silicon (c-Si) technologies are promising because of the high performance at low cost. Due to the low conductivity of a-Si:H, indium tin oxide

  18. 42 CFR 495.332 - State Medicaid health information technology (HIT) plan requirements.

    Science.gov (United States)

    2010-10-01

    ... and strategic plan for the next 5 years. (2) A description of how the State Medicaid HIT plan will be... processes that enable improved program administration for the Medicaid enterprise; (ii) Includes business... used certified EHR technology during the EHR reporting period, and that they have adopted, implemented...

  19. An orthogonal-polynomial approach to first-hitting times of birth-death processes

    NARCIS (Netherlands)

    van Doorn, Erik A.

    In a recent paper [J. Theor. Probab. 25 (2012) 950-980] Gong, Mao and Zhang, using the theory of Dirichlet forms, extended Karlin and McGregor's classical results on first-hitting times of a birth-death process on the nonnegative integers by establishing a representation for the Laplace transform

  20. Calibration Under Uncertainty.

    Energy Technology Data Exchange (ETDEWEB)

    Swiler, Laura Painton; Trucano, Timothy Guy

    2005-03-01

    This report is a white paper summarizing the literature and different approaches to the problem of calibrating computer model parameters in the face of model uncertainty. Model calibration is often formulated as finding the parameters that minimize the squared difference between the model-computed data (the predicted data) and the actual experimental data. This approach does not allow for explicit treatment of uncertainty or error in the model itself: the model is considered the %22true%22 deterministic representation of reality. While this approach does have utility, it is far from an accurate mathematical treatment of the true model calibration problem in which both the computed data and experimental data have error bars. This year, we examined methods to perform calibration accounting for the error in both the computer model and the data, as well as improving our understanding of its meaning for model predictability. We call this approach Calibration under Uncertainty (CUU). This talk presents our current thinking on CUU. We outline some current approaches in the literature, and discuss the Bayesian approach to CUU in detail.

  1. Radioactivity measurement of 18F in 16 ml vials for calibration of radionuclide calibrators

    International Nuclear Information System (INIS)

    Wurdiyanto, Gatot; Marsoem, Pujadi; Candra, Hermawan; Wijono, Paidi

    2012-01-01

    Fluorine-18 is obtained through the reaction 18 O(p, n) 18 F using a cyclotron that is situated in a hospital in Jakarta. Standardization of the 18 F solution is performed by gamma spectrometry using calibration sources of 152 Eu, 60 Co and 137 Cs that have traceability to the International System of units (SI). The activities in the 16 ml vials that were used for calibrating the radionuclide calibrators were between 1 and 2 GBq, with expanded uncertainties of 3.8%. The expanded uncertainty, at a coverage factor of k=2, on the derived calibration factor for the radionuclide calibrator was 6.6%. - Highlights: ► PTKMR–BATAN as a NMI of Indonesia is required to have procedures to calibrate the radionuclide calibrators. ► Standardizations were carried out on a solution of [ 18 F]FDG using gamma spectrometry. ► The volume of 18 F solutions used was 16 ml because this is the volume often used in hospitals. ► The Secondary Standard ionization chamber is a CRC-7BT Capintec radionuclide calibrator. ► A dial setting for 16 ml of [ 18 F]FDG solution in a vial is 443 for the Capintec dose calibrator.

  2. Current drive experiments in the HIT-II spherical tokamak

    International Nuclear Information System (INIS)

    Jarboe, T.R.; Gu, P.; Isso, V.A.; Jewell, P.E.; McCollam, K.J.; Nelson, B.A.; Ramon, R.; Redd, A.J.; Sieck, P.E.; Smith, R.J.; Nagata, M.; Uyama, T.

    2001-01-01

    The Helicity Injected Torus (Hit) program has made progress in understanding relaxation and helicity injection current drive. Helicity-conserving MHD activity during the inductive (Ohmic) current ramp demonstrates the profile flattening needed for coaxial helicity injection (CHI). Results from cathode and anode central column (CC) CHI pulses are consistent with the electron locking model of current drive from a pure n=1 mode. Finally, low density CHI, compatible with Ohmic operation, has been achieved. Some enhancement of CHI discharges with the application of Ohmic is shown. (author)

  3. Characterisation of a pre-cell hit detector to be used in single cell irradiation experiments at the Lund Nuclear Microprobe

    International Nuclear Information System (INIS)

    Nilsson, Charlotta; Pallon, Jan; Thungstroem, Goeran; Marrero, Natalia Arteaga; Elfman, Mikael; Kristiansson, Per; Nilsson, Christer; Wegden, Marie

    2008-01-01

    This paper describes the characterisation of an ultra-thin silicon semiconductor ΔE detector to be used as a pre-cell ion hit detector in single ion experiments on individual, living cells. The characteristics of interest for this specific application are the hit detection efficiency, which has to be close to 100% to enable bombardment with either a single ion or a counted number of ions, the beam spreading, which should be as small as possible to maintain the targeting accuracy, and the vacuum tightness, since the detector is intended, if possible, to be used simultaneously as vacuum window. The hit detection efficiency was shown to be above 99% when detecting alpha particles or 2 MeV protons, the increase in beam size was about 1 μm and the vacuum tightness was comparable to that of the Si 3 N 4 wafer which is normally used as vacuum window, thus the ΔE detector fulfils the main criteria to function properly as a single ion hit detector.

  4. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Mortensen, Niels Gylling; Hansen, Jens Carsten

    2007-01-01

    A field calibration method and results are described along with the experience gained with the method. The cup anemometers to be calibrated are mounted in a row on a 10-m high rig and calibrated in the free wind against a reference cup anemometer. The method has been reported [1] to improve...... the statistical bias on the data relative to calibrations carried out in a wind tunnel. The methodology is sufficiently accurate for calibration of cup anemometers used for wind resource assessments and provides a simple, reliable and cost-effective solution to cup anemometer calibration, especially suited...

  5. Calibration of Flick standards

    International Nuclear Information System (INIS)

    Thalmann, Ruedi; Spiller, Jürg; Küng, Alain; Jusko, Otto

    2012-01-01

    Flick standards or magnification standards are widely used for an efficient and functional calibration of the sensitivity of form measuring instruments. The results of a recent measurement comparison have shown to be partially unsatisfactory and revealed problems related to the calibration of these standards. In this paper the influence factors for the calibration of Flick standards using roundness measurement instruments are discussed in detail, in particular the bandwidth of the measurement chain, residual form errors of the device under test, profile distortions due to the diameter of the probing element and questions related to the definition of the measurand. The different contributions are estimated using simulations and are experimentally verified. Also alternative methods to calibrate Flick standards are investigated. Finally the practical limitations of Flick standard calibration are shown and the usability of Flick standards both to calibrate the sensitivity of roundness instruments and to check the filter function of such instruments is analysed. (paper)

  6. Synthesis Polarimetry Calibration

    Science.gov (United States)

    Moellenbrock, George

    2017-10-01

    Synthesis instrumental polarization calibration fundamentals for both linear (ALMA) and circular (EVLA) feed bases are reviewed, with special attention to the calibration heuristics supported in CASA. Practical problems affecting modern instruments are also discussed.

  7. Understanding Creation: Cosmology at the Dawn of the 21st Century

    Science.gov (United States)

    Lang, Andrew E.

    1997-01-01

    Cosmology attempts to answer questions concerning the origin of the universe, the way in which it evolves, and the way in which it will end. These are ancient questions that fascinate humanity and attendant metaphysical answers predate recorded history. The dawn of the 21st century has witnessed the first scientific answers. The goal of modern cosmology is to determine the basic properties of the universe. Numerous discoveries have been made in the last century which have had a profound influence on cosmology such as the expansion of the universe and the existence of the cosmic microwave background (CMB). CMB and other phenomena act as fossils for cosmologists who attempt to characterize the early universe through an interpretive methodology similar to that of archaeologists. Programs and tools such as NASA's Cosmic Background Explorer (COBE) have been designed to illuminate the morphologic history of the universe including the big bang theory and the current density of the universe. In this primer for cosmology, these and other discoveries and postulations are discussed.

  8. Ionoluminescence analysis of glass scintillators and application to single-ion-hit real-time detection

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Akihito, E-mail: yokoyama.akihito@jaea.go.jp [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); Takasaki Advanced Radiation Research Institute (TARRI), Japan Atomic Energy Agency (JAEA), 1233 Watanuki-machi, Takasaki, Gunma 370-1292 (Japan); Kada, Wataru [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); Satoh, Takahiro; Koka, Masashi [Takasaki Advanced Radiation Research Institute (TARRI), Japan Atomic Energy Agency (JAEA), 1233 Watanuki-machi, Takasaki, Gunma 370-1292 (Japan); Shimada, Keisuke; Yokoata, Yuya; Miura, Kenta; Hanaizumi, Osamu [Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan)

    2016-03-15

    In this paper, we propose and test a real-time detection system for single-ion hits using mega-electronvolt (MeV)-heavy ions. The system was constructed using G2000 and G9 glass scintillators, as well as an electron-multiplying charge-coupled device (EMCCD) camera combined with an inverted microscope with a 10× objective lens. Commercially available G2000 and G9 glass scintillators, which have been reported to exhibit strong photoluminescence at 489, 543, 585, and 622 nm as a result of the Tb{sup 3+} f–f transition, were employed for highly accurate ionized particle detection. The EMCCD camera had a resolution of 512 × 512 pixels, each with a size of 16 μm × 16 μm, and a maximum linear gain of 8 × 10{sup 5} electrons. For 260-MeV Ne, 3 ion hits/s were detected by our system. The intensity of the ionoluminescence (IL) peak induced by the heavy ions was 140 times the noise intensity. In contrast, the luminous diameter at the full width at half maximum (FWHM) in both the horizontal and vertical directions was calculated to be approximately 4.5 μm. These results suggest that our detection system can accurately detect single-ion hits with a diameter of the order of 1 μm.

  9. On the Occurrence of Magnetic Reconnection Along the Dawn and Dusk Magnetopause

    Science.gov (United States)

    Petrinec, S. M.; Burch, J. L.; Fuselier, S. A.; Trattner, K. J.; Gomez, R. G.; Giles, B. L.; Pollock, C.; Russell, C. T.; Strangeway, R. J.

    2017-12-01

    Magnetic reconnection is recognized as the primary process by which bulk solar wind plasma is able to enter the magnetosphere. The amount of plasma and energy transport is affected by the reconnection rate along the reconnection line as well as the spatial extent of the reconnection line. These parameters are in turn influenced by parameters such as the orientation of the interplanetary magnetic field (IMF), the dipole tilt angle of the Earth, and the local change in plasma beta between the magnetosheath and magnetosphere. Local variations of magnetosheath parameters are influenced by the character of the standing bow shock upstream of the observing location; i.e., there is greater variation downstream of the quasi-parallel shock than downstream of the quasi-perpendicular shock. Observations from the MMS mission are used to examine the occurrence of quasi-steady magnetic reconnection along the dawn and dusk regions of the magnetopause, and to determine the influence of local magnetosheath variations on the characteristics of the extended reconnection line.

  10. Sandia WIPP calibration traceability

    Energy Technology Data Exchange (ETDEWEB)

    Schuhen, M.D. [Sandia National Labs., Albuquerque, NM (United States); Dean, T.A. [RE/SPEC, Inc., Albuquerque, NM (United States)

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities.

  11. Sandia WIPP calibration traceability

    International Nuclear Information System (INIS)

    Schuhen, M.D.; Dean, T.A.

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities

  12. Heparin- induced thrombocytopenia (HIT: a case report of CABG patient

    Directory of Open Access Journals (Sweden)

    Alireza Jahangirifard

    2016-08-01

    Full Text Available Heparin- induced thrombocytopenia (HIT is an antibody mediated adverse effect of heparin therapy which is classified into two subtypes, HITI which is non-immune, spontaneously reversible thrombocytopenia and; HITII which is an autoimmune-mediated adverse effect of heparin therapy. In this case report, we described a 65-year old male patient with HITII after coronary artery bypass grafting.Key words: Heparin- induced thrombocytopenia, Heparin- induced thrombosis, coronary artery bypass grafting.

  13. The immune imbalance in the second hit of pancreatitis is independent of IL-17A.

    Science.gov (United States)

    Thomson, John-Edwin; Brand, Martin; Fonteh, Pascaline

    2018-04-01

    Severe acute pancreatitis (SAP) is characterised by two distinct clinical phases. Organ dysfunction and death is initially as a result of a systemic inflammatory response syndrome (SIRS). Systemic sepsis from infected pancreatic necrosis characterises the second phase, the so called 'second hit' of acute pancreatitis (AP). An immune imbalance during the second hit is postulated to contribute to the formation of the septic complications that occur in these patients. The pro-inflammatory T-helper (Th) 17 pathway has been shown to be an initiator of early SIRS in AP, however to date its role has not been established in the second hit in AP. Thirty-six patients with mild (n = 16), moderate (n = 10) and severe (n = 10) acute pancreatitis were enrolled. Peripheral blood samples were drawn on days 7, 9, 11 and 13 of illness for analysis of routine clinical markers as well as cytokine analysis. Flow cytometry and a IL-17A ELISA was performed to determine cytokine concentrations. There were no significant differences between days 7, 9, 11 and 13 for either the mild/moderate or SAP groups for IL-17A (CBA assay or ELISA), IFN-γ, TNF-α, IL-2 or IL-4. For each of the study days, the mean IL-6 and IL-10 concentrations were significantly higher in the SAP group compared to the mild/moderate group. WCC, CRP and PCT were all significantly higher in severe acute pancreatitis over the study days. An immune imbalance exists in patients with SAP, however secreted IL-17A is not responsible for the second hit in AP. Copyright © 2018 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  14. POLCAL - POLARIMETRIC RADAR CALIBRATION

    Science.gov (United States)

    Vanzyl, J.

    1994-01-01

    Calibration of polarimetric radar systems is a field of research in which great progress has been made over the last few years. POLCAL (Polarimetric Radar Calibration) is a software tool intended to assist in the calibration of Synthetic Aperture Radar (SAR) systems. In particular, POLCAL calibrates Stokes matrix format data produced as the standard product by the NASA/Jet Propulsion Laboratory (JPL) airborne imaging synthetic aperture radar (AIRSAR). POLCAL was designed to be used in conjunction with data collected by the NASA/JPL AIRSAR system. AIRSAR is a multifrequency (6 cm, 24 cm, and 68 cm wavelength), fully polarimetric SAR system which produces 12 x 12 km imagery at 10 m resolution. AIRSTAR was designed as a testbed for NASA's Spaceborne Imaging Radar program. While the images produced after 1991 are thought to be calibrated (phase calibrated, cross-talk removed, channel imbalance removed, and absolutely calibrated), POLCAL can and should still be used to check the accuracy of the calibration and to correct it if necessary. Version 4.0 of POLCAL is an upgrade of POLCAL version 2.0 released to AIRSAR investigators in June, 1990. New options in version 4.0 include automatic absolute calibration of 89/90 data, distributed target analysis, calibration of nearby scenes with calibration parameters from a scene with corner reflectors, altitude or roll angle corrections, and calibration of errors introduced by known topography. Many sources of error can lead to false conclusions about the nature of scatterers on the surface. Errors in the phase relationship between polarization channels result in incorrect synthesis of polarization states. Cross-talk, caused by imperfections in the radar antenna itself, can also lead to error. POLCAL reduces cross-talk and corrects phase calibration without the use of ground calibration equipment. Removing the antenna patterns during SAR processing also forms a very important part of the calibration of SAR data. Errors in the

  15. Evolution of asteroid (4) Vesta in the light of Dawn

    Science.gov (United States)

    Thangjam, Guneshwar; Mengel, Kurt; Nathues, Andreas; Schmidt, Kai H.; Hoffmann, Martin

    2016-04-01

    Asteroid (4) Vesta has been visited by the NASA Dawn spacecraft in 2011/12. The combination of compositional/elemental information from the three onboard instruments with mineralogical information from the howardite-eucrite-diogenite (HED) clan of stony achondrites has shed new light on the surface lithologic heterogeneity and the early evolution. Although petrologic/chemical models have tried to unravel the evolutionary processes, inconsistencies exist for some chemical major element/phase [e.g., 1, 2]. A revised evolutionary model is presented here [3]. The three oxygen isotope signature of HEDs and, thus, of proto-Vesta is best met by a mixture of 80% ordinary plus 20 % CV chondrites. Assuming a 27Al-triggered magma ocean within the first MA after accretion and taking into account the reliable major element data of the silicate fraction of the chondritic mixture results a crystallization sequence that differs from the earlier models [1, 2, 3]. The crystallized phase obtained by 'MELTS' software [4] starts with olivine and continues with minor olivine plus orthopyroxene until the liquid reaches a Kd value (partition coefficient) of 0.31 where the fractionated melt is in equilibrium with the residual liquid [5]. The abundance of minerals and rocks formed in this model are converted in volume proportions assuming a spherical shape of early Vesta (262 km radius) with a core (FeNi, FeNiS) radius of 110 km [6]. Two scenarios are considered to describe the early bulk silicate Vesta. First, the early-crystallized olivine accumulated at the base of the silicate shell is accounted for a dunitic lower mantle having a thickness of 46 km while the later crystallized phases form an orthopyroxenitic upper mantle and a crust of thickness 84 and 22 km, respectively. Second, an olivine-rich lower mantle that gradually changes to orthopyroxene-rich upper mantle is expected having an overall shell thickness of 137 km, with a 15 km thick crust. An important result is that the deep

  16. Hit and lead criteria in drug discovery for infectious diseases of the developing world.

    Science.gov (United States)

    Katsuno, Kei; Burrows, Jeremy N; Duncan, Ken; Hooft van Huijsduijnen, Rob; Kaneko, Takushi; Kita, Kiyoshi; Mowbray, Charles E; Schmatz, Dennis; Warner, Peter; Slingsby, B T

    2015-11-01

    Reducing the burden of infectious diseases that affect people in the developing world requires sustained collaborative drug discovery efforts. The quality of the chemical starting points for such projects is a key factor in improving the likelihood of clinical success, and so it is important to set clear go/no-go criteria for the progression of hit and lead compounds. With this in mind, the Japanese Global Health Innovative Technology (GHIT) Fund convened with experts from the Medicines for Malaria Venture, the Drugs for Neglected Diseases initiative and the TB Alliance, together with representatives from the Bill &Melinda Gates Foundation, to set disease-specific criteria for hits and leads for malaria, tuberculosis, visceral leishmaniasis and Chagas disease. Here, we present the agreed criteria and discuss the underlying rationale.

  17. Calibrating nacelle lidars

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, M.

    2013-01-15

    Nacelle mounted, forward looking wind lidars are beginning to be used to provide reference wind speed measurements for the power performance testing of wind turbines. In such applications, a formal calibration procedure with a corresponding uncertainty assessment will be necessary. This report presents four concepts for performing such a nacelle lidar calibration. Of the four methods, two are found to be immediately relevant and are pursued in some detail. The first of these is a line of sight calibration method in which both lines of sight (for a two beam lidar) are individually calibrated by accurately aligning the beam to pass close to a reference wind speed sensor. A testing procedure is presented, reporting requirements outlined and the uncertainty of the method analysed. It is seen that the main limitation of the line of sight calibration method is the time required to obtain a representative distribution of radial wind speeds. An alternative method is to place the nacelle lidar on the ground and incline the beams upwards to bisect a mast equipped with reference instrumentation at a known height and range. This method will be easier and faster to implement and execute but the beam inclination introduces extra uncertainties. A procedure for conducting such a calibration is presented and initial indications of the uncertainties given. A discussion of the merits and weaknesses of the two methods is given together with some proposals for the next important steps to be taken in this work. (Author)

  18. An orthogonal-polynomial approach to first-hitting times of birth-death processes

    NARCIS (Netherlands)

    van Doorn, Erik A.

    In a recent paper in this journal, Gong, Mao and Zhang, using the theory of Dirichlet forms, extended Karlin and McGregor’s classical results on first-hitting times of a birth–death process on the nonnegative integers by establishing a representation for the Laplace transform E[exp(sTij)] of the

  19. Calibrated Properties Model

    International Nuclear Information System (INIS)

    Ahlers, C.; Liu, H.

    2000-01-01

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the ''AMR Development Plan for U0035 Calibrated Properties Model REV00. These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions

  20. Effects of panaxadiol saponins on contents of TNF-α and IL-6 in two-hit rat models with hemorrhage and lipopolysaech

    International Nuclear Information System (INIS)

    Yu Zhenxiang; Ding Yanhua; Li Lu; Zhao Xuejian

    2005-01-01

    Objective: To explore the changes of serum TNF-α and IL-6 contents in the two-hit rat models with hemorrhage and lipopolysaech (LPS) and the effects of panaxadiol saponins (PDS) on TNF-α and contents IL-6. Methods: Adult Wistar rats were randomly divided into 5 groups: sham operational group (S), hemorrhage group (H), two-hit group with hemorrhage and LPS groups (HL), Dexamethasone pretreatment group (HLD), PDS pretreatment group (HLP). The rat models were made by hemorrhagic shock as the first hit and with endotoxin as the second hit. Then the rats were killed after 6 h. The contents of serum TNF-α and IL-6 in rats were measured by radioimmunoassay. Results: The serum TNF-α and IL-6 contents in HL group were increased significantly compared with S group or H group (P<0.001). The TNF-α and IL-6 contents in HLP group and HLD group were significantly lower than those in HL group (P<0.01). Conclusion: LPS can increase significantly the contents of serum TNF-α and IL-6 in rats with hemorrhagic shock. PDS can inhibit the release of serum TNF-α and IL-6, and has the same effects with DEX to protect against the tissue injuries of two-hit rats with hemorrhage and LPS. (authors)

  1. Anti-diabetic potential of the essential oil of Pinus koraiensis leaves toward streptozotocin-treated mice and HIT-T15 pancreatic β cells.

    Science.gov (United States)

    Joo, Hye-Eun; Lee, Hyo-Jung; Sohn, Eun Jung; Lee, Min-Ho; Ko, Hyun-Suk; Jeong, Soo-Jin; Lee, Hyo-Jeong; Kim, Sung-Hoon

    2013-01-01

    The metabolic syndrome creates risk factors for coronary heart disease, diabetes, fatty liver, obesity and several cancers. Our group has already reported that the essential oil from leaves of Pinus koraiensis SIEB (EOPK) exerted antihyperlipidemic effects by upregulating the low-density lipoprotein receptor and inhibiting acyl-coenzyme A, cholesterol acyltransferases. We evaluated in the current study the anti-diabetic effects of EOPK on mice with streptozotocin (STZ)-induced type I diabetes and on HIT-T15 pancreatic β cells. EOPK significantly protected HIT-T15 cells from STZ-induced cytotoxicity and reduced the blood glucose level in STZ-induced diabetic mice when compared with the untreated control. EOPK consistently and significantly suppressed the α-amylase activity in a dose-dependent manner and enhanced the expression of insulin at the mRNA level in STZ-treated HIT-T15 cells, while the expression of insulin was attenuated. EOPK also significantly abrogated the population of reactive oxygen species when compared to the untreated control in STZ-treated HIT-T15 cells. Furthermore, EOPK significantly reduce nitric oxide production, suppressed the phosphorylation of endothelial nitric oxide (NO) synthase and suppressed the production of vascular endothelial growth factor (VEGF) in STZ-treated HIT-T15 cells, implying its potential application to diabetic retinopathy. Overall, our findings suggest that EOPK had hypoglycemic potential by inhibiting reactive oxygene species (ROS), endothelial NO synthase (eNOS) and VEGF in STZ-treated mice and HIT-T15 pancreatic β cells as a potent anti-diabetic agent.

  2. Two-fluid (plasma-neutral) Extended-MHD simulations of spheromak configurations in the HIT-SI experiment with PSI-Tet

    Science.gov (United States)

    Sutherland, D. A.; Hansen, C. J.; Jarboe, T. R.

    2017-10-01

    A self-consistent, two-fluid (plasma-neutral) dynamic neutral model has been implemented into the 3-D, Extended-MHD code PSI-Tet. A monatomic, hydrogenic neutral fluid reacts with a plasma fluid through elastic scattering collisions and three inelastic collision reactions: electron-impact ionization, radiative recombination, and resonant charge-exchange. Density, momentum, and energy are evolved for both the plasma and neutral species. The implemented plasma-neutral model in PSI-Tet is being used to simulate decaying spheromak configurations in the HIT-SI experimental geometry, which is being compare to two-photon absorption laser induced fluorescence measurements (TALIF) made on the HIT-SI3 experiment. TALIF is used to measure the absolute density and temperature of monatomic deuterium atoms. Neutral densities on the order of 1015 m-3 and neutral temperatures between 0.6-1.7 eV were measured towards the end of decay of spheromak configurations with initial toroidal currents between 10-12 kA. Validation results between TALIF measurements and PSI-Tet simulations with the implemented dynamic neutral model will be presented. Additionally, preliminary dynamic neutral simulations of the HIT-SI/HIT-SI3 spheromak plasmas sustained with inductive helicity injection will be presented. Lastly, potential benefits of an expansion of the two-fluid model into a multi-fluid model that includes multiple neutral species and tracking of charge states will be discussed.

  3. Simulation of injector dynamics during steady inductive helicity injection current drive in the HIT-SI experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, C., E-mail: hansec@uw.edu [PSI-Center, University of Washington, Seattle, Washington 98195 (United States); Columbia University, New York, New York 10027 (United States); Marklin, G. [PSI-Center, University of Washington, Seattle, Washington 98195 (United States); Victor, B. [HIT-SI Group, University of Washington, Seattle, Washington 98195 (United States); Akcay, C. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Jarboe, T. [HIT-SI Group, University of Washington, Seattle, Washington 98195 (United States); PSI-Center, University of Washington, Seattle, Washington 98195 (United States)

    2015-04-15

    We present simulations of inductive helicity injection in the Helicity Injected Torus with Steady Inductive helicity injection (HIT-SI) device that treats the entire plasma volume in a single dynamic MHD model. A new fully 3D numerical tool, the PSI-center TETrahedral mesh code, was developed that provides the geometric flexibility required for this investigation. Implementation of a zero-β Hall MHD model using PSI-TET will be presented including formulation of a new self-consistent magnetic boundary condition for the wall of the HIT-SI device. Results from simulations of HIT-SI are presented focusing on injector dynamics that are investigated numerically for the first time. Asymmetries in the plasma loading between the two helicity injectors and progression of field reversal in each injector are observed. Analysis indicates cross-coupling between injectors through confinement volume structures. Injector impedance is found to scale with toroidal current at fixed density, consistent with experimental observation. Comparison to experimental data with an injector drive frequency of 14.5 kHz shows good agreement with magnetic diagnostics. Global mode structures from Bi-Orthogonal decomposition agree well with experimental data for the first four modes.

  4. Automation of dosimeters calibration for radiotherapy in secondary dosimetric calibration laboratory of the CPHR

    International Nuclear Information System (INIS)

    Acosta, Andy L. Romero; Lores, Stefan Gutierrez

    2013-01-01

    This paper presents the design and implementation of an automated system for measurements in the calibration of reference radiation dosimeters. It was made a software application that performs the acquisition of the measured values of electric charge, calculated calibration coefficient and automates the calibration certificate issuance. These values are stored in a log file on a PC. The use of the application improves control over the calibration process, helps to humanize the work and reduces personnel exposure. The tool developed has been applied to the calibration of dosimeters radiation patterns in the LSCD of the Centro de Proteccion e Higiene de las Radiaciones, Cuba

  5. Primary calibration in acoustics metrology

    International Nuclear Information System (INIS)

    Milhomem, T A Bacelar; Soares, Z M Defilippo

    2015-01-01

    SI unit in acoustics is realized by the reciprocity calibrations of laboratory standard microphones in pressure field, free field and diffuse field. Calibrations in pressure field and in free field are already consolidated and the Inmetro already done them. Calibration in diffuse field is not yet consolidated, however, some national metrology institutes, including Inmetro, are conducting researches on this subject. This paper presents the reciprocity calibration, the results of Inmetro in recent key comparisons and the research that is being developed for the implementation of reciprocity calibration in diffuse field

  6. Calibrated Properties Model

    International Nuclear Information System (INIS)

    Ahlers, C.F.; Liu, H.H.

    2001-01-01

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the AMR Development Plan for U0035 Calibrated Properties Model REV00 (CRWMS M and O 1999c). These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions

  7. Radiometric Calibration of Osmi Imagery Using Solar Calibration

    Directory of Open Access Journals (Sweden)

    Dong-Han Lee

    2000-12-01

    Full Text Available OSMI (Ocean Scanning Multi-Spectral Imager raw image data (Level 0 were acquired and radiometrically corrected. We have applied two methods, using solar & dark calibration data from OSMI sensor and comparing with the SeaWiFS data, to the radiometric correction of OSMI raw image data. First, we could get the values of the gain and the offset for each pixel and each band from comparing the solar & dark calibration data with the solar input radiance values, calculated from the transmittance, BRDF (Bidirectional Reflectance Distribution Function and the solar incidence angle (¥â,¥è of OSMI sensor. Applying this calibration data to OSMI raw image data, we got the two odd results, the lower value of the radiometric corrected image data than the expected value, and the Venetian Blind Effect in the radiometric corrected image data. Second, we could get the reasonable results from comparing OSMI raw image data with the SeaWiFS data, and get a new problem of OSMI sensor.

  8. Are We There Yet? Applying Thermodynamic and Kinetic Profiling on Embryonic Ectoderm Development (EED) Hit-to-Lead Program.

    Science.gov (United States)

    Wang, Ying; Edalji, Rohinton P; Panchal, Sanjay C; Sun, Chaohong; Djuric, Stevan W; Vasudevan, Anil

    2017-10-26

    It is advocated that kinetic and thermodynamic profiling of bioactive compounds should be incorporated and utilized as complementary tools for hit and lead optimizations in drug discovery. To assess their applications in the EED hit-to-lead optimization process, large amount of thermodynamic and kinetic data were collected and analyzed via isothermal titration calorimetry (ITC) and surface plasmon resonance (SPR), respectively. Slower dissociation rates (k off ) of the lead compounds were observed as the program progressed. Analysis of the kinetic data indicated that compound cellular activity correlated with both K i and k off . Our analysis revealed that ITC data should be interpreted in the context of chiral purity of the compounds. The thermodynamic signatures of the EED aminopyrrolidine compounds were found to be mainly enthalpy driven with improved enthalpic contributions as the program progressed. Our study also demonstrated that significant challenges still exist in utilizing kinetic and thermodynamic parameters for hit selection.

  9. Fragment-assisted hit investigation involving integrated HTS and fragment screening: Application to the identification of phosphodiesterase 10A (PDE10A) inhibitors.

    Science.gov (United States)

    Varnes, Jeffrey G; Geschwindner, Stefan; Holmquist, Christopher R; Forst, Janet; Wang, Xia; Dekker, Niek; Scott, Clay W; Tian, Gaochao; Wood, Michael W; Albert, Jeffrey S

    2016-01-01

    Fragment-based drug design (FBDD) relies on direct elaboration of fragment hits and typically requires high resolution structural information to guide optimization. In fragment-assisted drug discovery (FADD), fragments provide information to guide selection and design but do not serve as starting points for elaboration. We describe FADD and high-throughput screening (HTS) campaign strategies conducted in parallel against PDE10A where fragment hit co-crystallography was not available. The fragment screen led to prioritized fragment hits (IC50's ∼500μM), which were used to generate a hypothetical core scaffold. Application of this scaffold as a filter to HTS output afforded a 4μM hit, which, after preparation of a small number of analogs, was elaborated into a 16nM lead. This approach highlights the strength of FADD, as fragment methods were applied despite the absence of co-crystallographical information to efficiently identify a lead compound for further optimization. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. AFM lateral force calibration for an integrated probe using a calibration grating

    International Nuclear Information System (INIS)

    Wang, Huabin; Gee, Michelle L.

    2014-01-01

    Atomic force microscopy (AFM) friction measurements on hard and soft materials remain a challenge due to the difficulties associated with accurately calibrating the cantilever for lateral force measurement. One of the most widely accepted lateral force calibration methods is the wedge method. This method is often used in a simplified format but in so doing sacrifices accuracy. In the present work, we have further developed the wedge method to provide a lateral force calibration method for integrated AFM probes that is easy to use without compromising accuracy and reliability. Raw friction calibration data are collected from a single scan image by continuous ramping of the set point as the facets of a standard grating are scanned. These data are analysed to yield an accurate lateral force conversion/calibration factor that is not influenced by adhesion forces or load deviation. By demonstrating this new calibration method, we illustrate its reliability, speed and ease of execution. This method makes accessible reliable boundary lubrication studies on adhesive and heterogeneous surfaces that require spatial resolution of frictional forces. - Highlights: • We develop a simple and accurate method for lateral force calibration in AFM friction measurements. • We detail the basis of the method and illustrate how to use it and its reliability with example data. • Our method is easy, accurate and accounts for the affects of adhesion on friction measurements. • The method is applicable to integrated probes, as opposed to colloidal probes. • This allows accurate AFM friction measurements on spatially heterogeneous and adhesive surfaces

  11. FedWeb Greatest Hits: Presenting the New Test Collection for Federated Web Search

    NARCIS (Netherlands)

    Demeester, Thomas; Trieschnigg, Rudolf Berend; Zhou, Ke; Nguyen, Dong-Phuong; Hiemstra, Djoerd

    This paper presents 'FedWeb Greatest Hits', a large new test collection for research in web information retrieval. As a combination and extension of the datasets used in the TREC Federated Web Search Track, this collection opens up new research possibilities on federated web search challenges, as

  12. Enhancing hit identification in Mycobacterium tuberculosis drug discovery using validated dual-event Bayesian models.

    Directory of Open Access Journals (Sweden)

    Sean Ekins

    Full Text Available High-throughput screening (HTS in whole cells is widely pursued to find compounds active against Mycobacterium tuberculosis (Mtb for further development towards new tuberculosis (TB drugs. Hit rates from these screens, usually conducted at 10 to 25 µM concentrations, typically range from less than 1% to the low single digits. New approaches to increase the efficiency of hit identification are urgently needed to learn from past screening data. The pharmaceutical industry has for many years taken advantage of computational approaches to optimize compound libraries for in vitro testing, a practice not fully embraced by academic laboratories in the search for new TB drugs. Adapting these proven approaches, we have recently built and validated Bayesian machine learning models for predicting compounds with activity against Mtb based on publicly available large-scale HTS data from the Tuberculosis Antimicrobial Acquisition Coordinating Facility. We now demonstrate the largest prospective validation to date in which we computationally screened 82,403 molecules with these Bayesian models, assayed a total of 550 molecules in vitro, and identified 124 actives against Mtb. Individual hit rates for the different datasets varied from 15-28%. We have identified several FDA approved and late stage clinical candidate kinase inhibitors with activity against Mtb which may represent starting points for further optimization. The computational models developed herein and the commercially available molecules derived from them are now available to any group pursuing Mtb drug discovery.

  13. Syringe calibration factors and volume correction factors for the NPL secondary standard radionuclide calibrator

    CERN Document Server

    Tyler, D K

    2002-01-01

    The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.

  14. The GERDA calibration system

    Energy Technology Data Exchange (ETDEWEB)

    Baudis, Laura; Froborg, Francis; Tarka, Michael; Bruch, Tobias; Ferella, Alfredo [Physik-Institut, Universitaet Zuerich (Switzerland); Collaboration: GERDA-Collaboration

    2012-07-01

    A system with three identical custom made units is used for the energy calibration of the GERDA Ge diodes. To perform a calibration the {sup 228}Th sources are lowered from the parking positions at the top of the cryostat. Their positions are measured by two independent modules. One, the incremental encoder, counts the holes in the perforated steel band holding the sources, the other measures the drive shaft's angular position even if not powered. The system can be controlled remotely by a Labview program. The calibration data is analyzed by an iterative calibration algorithm determining the calibration functions for different energy reconstruction algorithms and the resolution of several peaks in the {sup 228}Th spectrum is determined. A Monte Carlo simulation using the GERDA simulation software MAGE has been performed to determine the background induced by the sources in the parking positions.

  15. RF impedance measurement calibration

    International Nuclear Information System (INIS)

    Matthews, P.J.; Song, J.J.

    1993-01-01

    The intent of this note is not to explain all of the available calibration methods in detail. Instead, we will focus on the calibration methods of interest for RF impedance coupling measurements and attempt to explain: (1). The standards and measurements necessary for the various calibration techniques. (2). The advantages and disadvantages of each technique. (3). The mathematical manipulations that need to be applied to the measured standards and devices. (4). An outline of the steps needed for writing a calibration routine that operated from a remote computer. For further details of the various techniques presented in this note, the reader should consult the references

  16. Robot-assisted automatic ultrasound calibration.

    Science.gov (United States)

    Aalamifar, Fereshteh; Cheng, Alexis; Kim, Younsu; Hu, Xiao; Zhang, Haichong K; Guo, Xiaoyu; Boctor, Emad M

    2016-10-01

    Ultrasound (US) calibration is the process of determining the unknown transformation from a coordinate frame such as the robot's tooltip to the US image frame and is a necessary task for any robotic or tracked US system. US calibration requires submillimeter-range accuracy for most applications, but it is a time-consuming and repetitive task. We provide a new framework for automatic US calibration with robot assistance and without the need for temporal calibration. US calibration based on active echo (AE) phantom was previously proposed, and its superiority over conventional cross-wire phantom-based calibration was shown. In this work, we use AE to guide the robotic arm motion through the process of data collection; we combine the capability of the AE point to localize itself in the frame of the US image with the automatic motion of the robotic arm to provide a framework for calibrating the arm to the US image automatically. We demonstrated the efficacy of the automated method compared to the manual method through experiments. To highlight the necessity of frequent ultrasound calibration, it is demonstrated that the calibration precision changed from 1.67 to 3.20 mm if the data collection is not repeated after a dismounting/mounting of the probe holder. In a large data set experiment, similar reconstruction precision of automatic and manual data collection was observed, while the time was reduced by 58 %. In addition, we compared ten automatic calibrations with ten manual ones, each performed in 15 min, and showed that all the automatic ones could converge in the case of setting the initial matrix as identity, while this was not achieved by manual data sets. Given the same initial matrix, the repeatability of the automatic was [0.46, 0.34, 0.80, 0.47] versus [0.42, 0.51, 0.98, 1.15] mm in the manual case for the US image four corners. The submillimeter accuracy requirement of US calibration makes frequent data collections unavoidable. We proposed an automated

  17. The control of auroral zone dynamics and thermodynamics by the interplanetary magnetic field dawn-dusk (Y) component

    International Nuclear Information System (INIS)

    Sica, R.J.; Hernandez, G.; Emery, B.A.; Roble, R.G.; Smith, R.W.; Rees, M.H.

    1989-01-01

    Previous theoretical and experimental studies have shown that the dawn-dusk component of the interplanetary magnetic field (IMF B y ) expands the classical symmetric two-cell convection pattern toward dusk (B y negative) or toward dawn (B y positive) in the northern hemisphere, altering the ion drag forcing on the neutral atmosphere. Measurements of the neutral dynamics associated with these convection patterns have been presented primarily at magnetic latitudes greater than 70 degree in the polar cap. In this study, nights with coincident IMF measurements have been selected from the extensive four-year auroral zone thermospheric wind and temperature data set derived from Fabry-Perot spectrometer measurements of the Doppler shifts and widths of the O( 1 D) 15,867 cm -1 (630.0 nm) emission from College, Alaska. Averages from 112 nights of measurements from College were also computed using a selection criterion that depended on the previous 2 hours of IMF measurements (case 2). This procedure yielded averages that differed at times from case 1. The wind and temperature averages for both cases show large variations with B y in the auroral zone. The wind averages for B y negative and positive are compared with National Center for Atmospheric Research thermospheric general circulation model predictions that use a B y -dependent model of ionospheric convection. The results for B y negative and positive are compared with National Center for Atmospheric Research thermospheric general circulation model predictions that use a B y -dependent model of ionospheric convection. The results for B y negative compare favorably with the averages, but there are significant differences between model calculations and averages for the B y positive case

  18. Constraints on Ceres' Internal Structure and Evolution From Its Shape and Gravity Measured by the Dawn Spacecraft

    Science.gov (United States)

    Ermakov, A. I.; Fu, R. R.; Castillo-Rogez, J. C.; Raymond, C. A.; Park, R. S.; Preusker, F.; Russell, C. T.; Smith, D. E.; Zuber, M. T.

    2017-11-01

    Ceres is the largest body in the asteroid belt with a radius of approximately 470 km. In part due to its large mass, Ceres more closely approaches hydrostatic equilibrium than major asteroids. Pre-Dawn mission shape observations of Ceres revealed a shape consistent with a hydrostatic ellipsoid of revolution. The Dawn spacecraft Framing Camera has been imaging Ceres since March 2015, which has led to high-resolution shape models of the dwarf planet, while the gravity field has been globally determined to a spherical harmonic degree 14 (equivalent to a spatial wavelength of 211 km) and locally to 18 (a wavelength of 164 km). We use these shape and gravity models to constrain Ceres' internal structure. We find a negative correlation and admittance between topography and gravity at degree 2 and order 2. Low admittances between spherical harmonic degrees 3 and 16 are well explained by Airy isostatic compensation mechanism. Different models of isostasy give crustal densities between 1,200 and 1,400 kg/m3 with our preferred model giving a crustal density of 1,287+70-87 kg/m3. The mantle density is constrained to be 2,434+5-8 kg/m3. We compute isostatic gravity anomaly and find evidence for mascon-like structures in the two biggest basins. The topographic power spectrum of Ceres and its latitude dependence suggest that viscous relaxation occurred at the long wavelengths (>246 km). Our density constraints combined with finite element modeling of viscous relaxation suggests that the rheology and density of the shallow surface are most consistent with a rock, ice, salt and clathrate mixture.

  19. SPOTS Calibration Example

    Directory of Open Access Journals (Sweden)

    Patterson E.

    2010-06-01

    Full Text Available The results are presented using the procedure outlined by the Standardisation Project for Optical Techniques of Strain measurement to calibrate a digital image correlation system. The process involves comparing the experimental data obtained with the optical measurement system to the theoretical values for a specially designed specimen. The standard states the criteria which must be met in order to achieve successful calibration, in addition to quantifying the measurement uncertainty in the system. The system was evaluated at three different displacement load levels, generating strain ranges from 289 µstrain to 2110 µstrain. At the 289 µstrain range, the calibration uncertainty was found to be 14.1 µstrain, and at the 2110 µstrain range it was found to be 28.9 µstrain. This calibration procedure was performed without painting a speckle pattern on the surface of the metal. Instead, the specimen surface was prepared using different grades of grit paper to produce the desired texture.

  20. ANALYSIS MUSIC CONCERTS ADOPTING THE MATHEMATICAL MODEL OF HIT PHENOMENA

    OpenAIRE

    Kawahata Yasuko; Genda Etsuo; Ishii Akira

    2013-01-01

    A mathematical model for the hit phenomenon in entertainment within a society is presented as a stochastic process of interactions of human dynamics. In this paper, we analyzed music to the concert.Knowing the cost of advertising the concert is difficult. But exposure to the media of the artist can be seen. We tried to analysis of music concert itself by performing a prediction of reputation of artists during the concert tour from this exposure.In this paper, The world most pop...

  1. Exploring the multiple-hit hypothesis of preterm white matter damage using diffusion MRI

    Directory of Open Access Journals (Sweden)

    Madeleine L. Barnett

    2018-01-01

    Conclusion: This study suggests multiple perinatal risk factors have an independent association with diffuse white matter injury at term equivalent age and exposure to multiple perinatal risk factors exacerbates dMRI defined, clinically significant white matter injury. Our findings support the multiple hit hypothesis for preterm white matter injury.

  2. A Study on Relative Radiometric Calibration without Calibration Field for YG-25

    Directory of Open Access Journals (Sweden)

    ZHANG Guo

    2017-08-01

    Full Text Available YG-25 is the first agility optical remote sensing satellite of China to acquire the sub-meter imagery of the earth. The side slither calibration technique is an on-orbit maneuver that has been used to flat-field image data acquired over the uniform calibration field. However, imaging to the single uniform calibration field cannot afford to calibrate the full dynamic response range of the sensor and reduces the efficiency. The paper proposes a new relative radiometric calibration method that a 90-degree yaw maneuver is performed over any non-uniform features of the Earth for YG-25. Meanwhile, we use an enhanced side slither image horizontal correction method based on line segment detector(LSDalgorithm to solve the side slither image over-shifted problem.The shifted results are compared with other horizontal correction method. The histogram match algorithm is used to calculate the relative gains of all detectors. The correctness and validity of the proposed method are validated by using the YG-25 on-board side slither data. The results prove that the mean streaking metrics of relative correction images of YG-25 is better 0.07%, the noticeable striping artifact and residual noise are removed, the calibration accuracy of side slither technique based on non-uniform features is superior to life image statistics of sensor's life span.

  3. Pulse-based internal calibration of polarimetric SAR

    DEFF Research Database (Denmark)

    Dall, Jørgen; Skou, Niels; Christensen, Erik Lintz

    1994-01-01

    Internal calibration greatly diminishes the dependence on calibration target deployment compared to external calibration. Therefore the Electromagnetics Institute (EMI) at the Technical University of Denmark (TUD) has equipped its polarimetric SAR, EMISAR, with several calibration loops and devel......Internal calibration greatly diminishes the dependence on calibration target deployment compared to external calibration. Therefore the Electromagnetics Institute (EMI) at the Technical University of Denmark (TUD) has equipped its polarimetric SAR, EMISAR, with several calibration loops...

  4. Site Calibration report

    DEFF Research Database (Denmark)

    Yordanova, Ginka; Vesth, Allan

    The report describes site calibration measurements carried out on a site in Denmark. The measurements are carried out in accordance to Ref. [1]. The site calibration is carried out before a power performance measurement on a given turbine to clarify the influence from the terrain on the ratio...

  5. LANL MTI calibration team experience

    Science.gov (United States)

    Bender, Steven C.; Atkins, William H.; Clodius, William B.; Little, Cynthia K.; Christensen, R. Wynn

    2004-01-01

    The Multispectral Thermal Imager (MTI) was designed as an imaging radiometer with absolute calibration requirements established by Department of Energy (DOE) mission goals. Particular emphasis was given to water surface temperature retrieval using two mid wave and three long wave infrared spectral bands, the fundamental requirement was a surface temperature determination of 1K at the 68% confidence level. For the ten solar reflective bands a one-sigma radiometric performance goal of 3% was established. In order to address these technical challenges a calibration facility was constructed containing newly designed sources that were calibrated at NIST. Additionally, the design of the payload and its onboard calibration system supported post launch maintenance and update of the ground calibration. The on-orbit calibration philosophy also included vicarious techniques using ocean buoys, playas and other instrumented sites; these became increasingly important subsequent to an electrical failure which disabled the onboard calibration system. This paper offers various relevant lessons learned in the eight-year process of reducing to practice the calibration capability required by the scientific mission. The discussion presented will include observations pertinent to operational and procedural issues as well as hardware experiences; the validity of some of the initial assumptions will also be explored.

  6. Vibration transducer calibration techniques

    Science.gov (United States)

    Brinkley, D. J.

    1980-09-01

    Techniques for the calibration of vibration transducers used in the Aeronautical Quality Assurance Directorate of the British Ministry of Defence are presented. Following a review of the types of measurements necessary in the calibration of vibration transducers, the performance requirements of vibration transducers, which can be used to measure acceleration, velocity or vibration amplitude, are discussed, with particular attention given to the piezoelectric accelerometer. Techniques for the accurate measurement of sinusoidal vibration amplitude in reference-grade transducers are then considered, including the use of a position sensitive photocell and the use of a Michelson laser interferometer. Means of comparing the output of working-grade accelerometers with that of previously calibrated reference-grade devices are then outlined, with attention given to a method employing a capacitance bridge technique and a method to be used at temperatures between -50 and 200 C. Automatic calibration procedures developed to speed up the calibration process are outlined, and future possible extensions of system software are indicated.

  7. Energy calibration issues in nuclear resonant vibrational spectroscopy: observing small spectral shifts and making fast calibrations.

    Science.gov (United States)

    Wang, Hongxin; Yoda, Yoshitaka; Dong, Weibing; Huang, Songping D

    2013-09-01

    The conventional energy calibration for nuclear resonant vibrational spectroscopy (NRVS) is usually long. Meanwhile, taking NRVS samples out of the cryostat increases the chance of sample damage, which makes it impossible to carry out an energy calibration during one NRVS measurement. In this study, by manipulating the 14.4 keV beam through the main measurement chamber without moving out the NRVS sample, two alternative calibration procedures have been proposed and established: (i) an in situ calibration procedure, which measures the main NRVS sample at stage A and the calibration sample at stage B simultaneously, and calibrates the energies for observing extremely small spectral shifts; for example, the 0.3 meV energy shift between the 100%-(57)Fe-enriched [Fe4S4Cl4](=) and 10%-(57)Fe and 90%-(54)Fe labeled [Fe4S4Cl4](=) has been well resolved; (ii) a quick-switching energy calibration procedure, which reduces each calibration time from 3-4 h to about 30 min. Although the quick-switching calibration is not in situ, it is suitable for normal NRVS measurements.

  8. On chromatic and geometrical calibration

    DEFF Research Database (Denmark)

    Folm-Hansen, Jørgen

    1999-01-01

    The main subject of the present thesis is different methods for the geometrical and chromatic calibration of cameras in various environments. For the monochromatic issues of the calibration we present the acquisition of monochrome images, the classic monochrome aberrations and the various sources...... the correct interpolation method is described. For the chromatic issues of calibration we present the acquisition of colour and multi-spectral images, the chromatic aberrations and the various lens/camera based non-uniformities of the illumination of the image plane. It is described how the monochromatic...... to design calibration targets for both geometrical and chromatic calibration are described. We present some possible systematical errors on the detection of the objects in the calibration targets, if viewed in a non orthogonal angle, if the intensities are uneven or if the image blurring is uneven. Finally...

  9. Calibration of triaxial fluxgate gradiometer

    International Nuclear Information System (INIS)

    Vcelak, Jan

    2006-01-01

    The description of simple and fast calibration procedures used for double-probe triaxial fluxgate gradiometer is provided in this paper. The calibration procedure consists of three basic steps. In the first step both probes are calibrated independently in order to reach constant total field reading in every position. Both probes are numerically aligned in the second step in order that the gradient reading is zero in homogenous magnetic field. The third step consists of periodic drift calibration during measurement. The results and detailed description of each calibration step are presented and discussed in the paper. The gradiometer is finally verified during the detection of the metal object in the measuring grid

  10. Combined postoperative irradiation and chemotherapy for anaplastic ependymomas in childhood: results of the German prospective trials hit 88/89 and hit 91

    International Nuclear Information System (INIS)

    Timmermann, Beate; Kortmann, Rolf-Dieter; Kuehl, Joachim; Meisner, Christoph; Slavc, Irene; Pietsch, Thorsten; Bamberg, Michael

    2000-01-01

    Purpose: To evaluate the outcome in children with anaplastic ependymomas after surgery, irradiation, and chemotherapy; and to identify prognostic factors for survival. Methods and Materials: Fifty-five children (n = 27 girls, 28 boys; median age at diagnosis, 6.2 years) with newly diagnosed anaplastic ependymomas were treated in the multicenter, prospective trials HIT 88/89 and HIT 91. Macroscopic complete resection was achieved in 28 patients; 27 patients underwent incomplete resection. All patients received chemotherapy before (n = 40) or after irradiation (n = 15). The irradiation volume encompassed either the neuraxis followed by a boost to the primary tumor site (n = 40) or the tumor region only (n = 13). No radiotherapy was administered in two patients. Results: Median follow-up was 38 months. The overall survival rate at 3 years after surgery was 75.6%. Disease progression occurred in 25 children with local progression occurring in 20. The median time to disease progression was 45 months. The only significant prognostic factor was the extent of resection (estimated progression-free survival [EPFS] after 3 years was 83.3% after complete resection and 38.5% after incomplete resection) and the presence of metastases at the time of diagnosis (0% vs. 65.8% 3-year EPFS in localized tumors). Age, sex, tumor site, mode of chemotherapy, and irradiation volume did not influence survival. Conclusions: Treatment centers should be meticulous about surgery and diagnostic workup. Because the primary tumor region is the predominant site of failure it is important to intensify local treatment. Dose escalation by hyperfractionation or stereotactic radiotherapy might be a promising approach in macroscopically residual disease. The role of adjuvant chemotherapy requires further study

  11. Calibrating Legal Judgments

    Directory of Open Access Journals (Sweden)

    Frederick Schauer

    2017-09-01

    Full Text Available Objective to study the notion and essence of legal judgments calibration the possibilities of using it in the lawenforcement activity to explore the expenses and advantages of using it. Methods dialectic approach to the cognition of social phenomena which enables to analyze them in historical development and functioning in the context of the integrity of objective and subjective factors it determined the choice of the following research methods formallegal comparative legal sociological methods of cognitive psychology and philosophy. Results In ordinary life people who assess other peoplersaquos judgments typically take into account the other judgments of those they are assessing in order to calibrate the judgment presently being assessed. The restaurant and hotel rating website TripAdvisor is exemplary because it facilitates calibration by providing access to a raterrsaquos previous ratings. Such information allows a user to see whether a particular rating comes from a rater who is enthusiastic about every place she patronizes or instead from someone who is incessantly hard to please. And even when less systematized as in assessing a letter of recommendation or college transcript calibration by recourse to the decisional history of those whose judgments are being assessed is ubiquitous. Yet despite the ubiquity and utility of such calibration the legal system seems perversely to reject it. Appellate courts do not openly adjust their standard of review based on the previous judgments of the judge whose decision they are reviewing nor do judges in reviewing legislative or administrative decisions magistrates in evaluating search warrant representations or jurors in assessing witness perception. In most legal domains calibration by reference to the prior decisions of the reviewee is invisible either because it does not exist or because reviewing bodies are unwilling to admit using what they in fact know and employ. Scientific novelty for the first

  12. Effects on ontogenesis of Carausius morosus hit by cosmic heavy ions

    International Nuclear Information System (INIS)

    Reitz, G.; Buecker, H.; Ruether, W.

    1990-01-01

    Among the biological problems that arise in long duration spaceflights, the effects of weightlessness and ionizing radiation appear to be the two main risk factors. Eggs of the stick insect Carausius morosus were exposed to spaceflight conditions during the 12.56 day Biosatellite mission Cosmos 1887. Five different ages were used, representing different sensitivities to radiation and different capacities for regeneration. During spaceflight the eggs continued their development. Already, in the Spacelab D1 mission in 1985, it has been shown that microgravity leads to a reduced hatching rate of eggs exposed during the early steps of development. When the eggs were hit by a heavy ion, a further but not significant reduction of the hatching rate was observed. Hatching was normal for eggs which were exposed on a 1 g reference centrifuge in space. Heavy ion hits caused body anomalies. The combined action of heavy ions and microgravity resulted in an unexpectedly high rate of anomalies. In the experiment on Cosmos 1887 these results were confirmed. Studies on the embryonic development before hatching showed no major difference between flight and ground control specimen, neither in speed of development nor in morphological anomalies. Hatching therefore seems to be the critical point in insect ontogenesis. (author)

  13. Mercury Continuous Emmission Monitor Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Eric Kalberer; Ryan Boysen; William Schuster; Joseph Rovani

    2009-03-12

    Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma

  14. A Review of Sensor Calibration Monitoring for Calibration Interval Extension in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Coble, Jamie B.; Meyer, Ryan M.; Ramuhalli, Pradeep; Bond, Leonard J.; Hashemian, Hash; Shumaker, Brent; Cummins, Dara

    2012-08-31

    Currently in the United States, periodic sensor recalibration is required for all safety-related sensors, typically occurring at every refueling outage, and it has emerged as a critical path item for shortening outage duration in some plants. Online monitoring can be employed to identify those sensors that require calibration, allowing for calibration of only those sensors that need it. International application of calibration monitoring, such as at the Sizewell B plant in United Kingdom, has shown that sensors may operate for eight years, or longer, within calibration tolerances. This issue is expected to also be important as the United States looks to the next generation of reactor designs (such as small modular reactors and advanced concepts), given the anticipated longer refueling cycles, proposed advanced sensors, and digital instrumentation and control systems. The U.S. Nuclear Regulatory Commission (NRC) accepted the general concept of online monitoring for sensor calibration monitoring in 2000, but no U.S. plants have been granted the necessary license amendment to apply it. This report presents a state-of-the-art assessment of online calibration monitoring in the nuclear power industry, including sensors, calibration practice, and online monitoring algorithms. This assessment identifies key research needs and gaps that prohibit integration of the NRC-approved online calibration monitoring system in the U.S. nuclear industry. Several needs are identified, including the quantification of uncertainty in online calibration assessment; accurate determination of calibration acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and assessment of the feasibility of using virtual sensor estimates to replace identified faulty sensors in order to extend operation to the next convenient maintenance opportunity. Understanding the degradation of sensors and the impact of this degradation on signals is key to

  15. Optimal Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Kroon, I. B.; Faber, Michael Havbro

    1994-01-01

    Calibration of partial safety factors is considered in general, including classes of structures where no code exists beforehand. The partial safety factors are determined such that the difference between the reliability for the different structures in the class considered and a target reliability...... level is minimized. Code calibration on a decision theoretical basis is also considered and it is shown how target reliability indices can be calibrated. Results from code calibration for rubble mound breakwater designs are shown....

  16. Observation models in radiocarbon calibration

    International Nuclear Information System (INIS)

    Jones, M.D.; Nicholls, G.K.

    2001-01-01

    The observation model underlying any calibration process dictates the precise mathematical details of the calibration calculations. Accordingly it is important that an appropriate observation model is used. Here this is illustrated with reference to the use of reservoir offsets where the standard calibration approach is based on a different model to that which the practitioners clearly believe is being applied. This sort of error can give rise to significantly erroneous calibration results. (author). 12 refs., 1 fig

  17. Assessment of HIT Antibody Complex in Hip Fracture Patients Receiving Enoxaparin or Unfractionated Heparin

    DEFF Research Database (Denmark)

    Griffin, Justin W; Hopkinson, William J; Rud-Lassen, Michael

    2011-01-01

    of antiheparin-PF4 antibodies and a greater prevalence of immunoglobulin G (IgG) subtype. Heparin and enoxaparin are capable of generating heparin-induced thrombocytopenia (HIT) antibodies in elderly patients undergoing orthopedic surgery but perhaps not to the same extent. When comparing low...

  18. Cost-effectiveness of the HIT programme in patients with schizophrenia and persistent auditory hallucinations

    NARCIS (Netherlands)

    Stant, AD; TenVergert, EM; Groen, H; Jenner, JA; Nienhuis, FJ; van de Willige, G; Wiersma, D

    Objective: To examine the cost-effectiveness of Hallucination focused Integrative Treatment (HIT) in patients with schizophrenia and a history of persistent auditory hallucinations. Method: Costs, in and outside the health care sector, and outcomes were registered prospectively during a period of 18

  19. Internal lecture: The dawn of the Standard Model's revolution | 6 June | Main Auditorium

    CERN Multimedia

    2014-01-01

    "The dawn of the Standard Model's revolution", by Luigi di Lella and Alvaro de Rujula.   Alvaro de Rujula. 15:30 - 16:20: Lecture by Alvaro de Rujula (followed by 20 minutes of questions) Abstract In the few years around November 1974, particle physics changed very significantly and at a frantic pace. Practitioners began to get accustomed to the successful predictions of the Standard Model, which did not have many believers at that time. I shall recall the main experimental and theoretical advances, concerning in particular quarks as partons, the asymptotic freedom of QCD, charmonia and the first openly charmed particles. Career Alvaro de Rújula was at Harvard University during the Standard Model revolution. Before and after, amongst many other places, he worked at CERN.   16:40 - 17:00: Coffee break   Luigi di Lella. 17:00 - 17:50: Lecture by Luigi di Lella: Experiments at CERN in the decade 1964-1974 (followed by 20 minut...

  20. Selection and optimization of hits from a high-throughput phenotypic screen against Trypanosoma cruzi.

    Science.gov (United States)

    Keenan, Martine; Alexander, Paul W; Chaplin, Jason H; Abbott, Michael J; Diao, Hugo; Wang, Zhisen; Best, Wayne M; Perez, Catherine J; Cornwall, Scott M J; Keatley, Sarah K; Thompson, R C Andrew; Charman, Susan A; White, Karen L; Ryan, Eileen; Chen, Gong; Ioset, Jean-Robert; von Geldern, Thomas W; Chatelain, Eric

    2013-10-01

    Inhibitors of Trypanosoma cruzi with novel mechanisms of action are urgently required to diversify the current clinical and preclinical pipelines. Increasing the number and diversity of hits available for assessment at the beginning of the discovery process will help to achieve this aim. We report the evaluation of multiple hits generated from a high-throughput screen to identify inhibitors of T. cruzi and from these studies the discovery of two novel series currently in lead optimization. Lead compounds from these series potently and selectively inhibit growth of T. cruzi in vitro and the most advanced compound is orally active in a subchronic mouse model of T. cruzi infection. High-throughput screening of novel compound collections has an important role to play in diversifying the trypanosomatid drug discovery portfolio. A new T. cruzi inhibitor series with good drug-like properties and promising in vivo efficacy has been identified through this process.