WorldWideScience

Sample records for highly lipophilic crown

  1. Synthesis and study of lipophilic crown ethers and thia-ligands. Application to nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Guyon, Vincent

    1992-01-01

    In the field of metal extraction from the solutions of nuclear fuel reprocessing, new specific complexing agents that are more efficient than tributyl phosphate must possess a high lipophilic character. The use of lipophilic crown ethers and thia-ligands has eliminated the problem related to their loss in the aqueous media. Moreover, it has made their complexes more soluble in organic solvents. The increase of lipophilic character of monocyclic polyethers has been realized with the addition of an alkyl chain and the development of a new process has made possible the separation of cis-syn-cis and cis-anti-cis isomers of dicyclohexano 18 crown 6 on an industrial scale. The creation of a rapid NMR method of analysis has permitted to study the extracting capacity of those crown ethers in relation to monovalent and divalent cations in nitric acid media and also to demonstrate the influence brought by different substituents. Some new lipophilic thia-ligands (macrocycles and podands) have also been prepared and the study of palladium extraction in nitric acid media by these compounds has led to a better understanding of the relation between the structure and the extracting capacity. Of easy access, some podands have an extracting selectivity and an extracting kinetic for this metal which are highly superior than those of dialkyl sulphides actually employed in the industry. This makes their use possible in the nuclear area. (author) [fr

  2. Highly lipophilic pluronics-conjugated polyamidoamine dendrimer nanocarriers as potential delivery system for hydrophobic drugs

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thi Tram Chau [Institute of Research and Development, Duy Tan University, Da Nang City 550000 (Viet Nam); Department of Chemical Engineering, Industrial University of HCMC, HCMC 70000 (Viet Nam); Nguyen, Cuu Khoa, E-mail: nckhoavnn@yahoo.com [Department of Materials and Pharmaceutical Chemistry, Vietnam Academy of Science and Technology, HCMC 70000 (Viet Nam); Nguyen, Thi Hiep [Biomedical Engineering Department, International University, National Universities in HCMC, HCMC 70000 (Viet Nam); Tran, Ngoc Quyen, E-mail: tnquyen@iams.vast.vn [Institute of Research and Development, Duy Tan University, Da Nang City 550000 (Viet Nam); Department of Materials and Pharmaceutical Chemistry, Vietnam Academy of Science and Technology, HCMC 70000 (Viet Nam)

    2017-01-01

    In the study, four kinds of pluronics (P123, F68, F127 and F108) with varying hydrophilic-lipophilic balance (HLB) values were modified and conjugated on 4th generation of polyamidoamine dendrimer (PAMAM). The obtained results from FT-IR, {sup 1}H NMR and GPC showed that the pluronics effectively conjugated on the dendrimer. The molecular weight of four PAMAM G4.0-Pluronics and its morphologies are in range of 200.15–377.14 kDa and around 60–180 nm in diameter by TEM, respectively. Loading efficiency and release of hydrophobic fluorouracil (5-FU) anticancer drug were evaluated by HPLC; Interesting that the dendrimer nanocarrier was conjugated with the highly lipophilic pluronic P123 (G4.0-P123) exhibiting a higher drug loading efficiency (up to 76.25%) in comparison with another pluronics. Live/dead fibroblast cell staining assay mentioned that all conjugated nanocarriers are highly biocompatible. The drug-loaded nanocarriers also indicated a highly anti-proliferative activity against MCF-7 breast cancer cell. The obtained results demonstrated a great potential of the highly lipophilic pluronics-conjugated nanocarriers in hydrophobic drugs delivery for biomedical applications. - Highlights: • Biocompatible pluronic-conjugated polyamidoamine dendrimers were prepared at nanoscale for drug delivery. • The dendrimer nanocarrier was decorated with a lipophilic pluronic exhibiting a higher drug loading efficiency. • The pluronic-functionalized nanocarriers demonstrated a great potential for delivering hydrophobic drugs.

  3. Photoimages and the release characteristics of lipophilic matrix tablets containing highly water-soluble potassium citrate with high drug loadings.

    Science.gov (United States)

    Cao, Qing-Ri; Kim, Tae-Wan; Lee, Beom-Jin

    2007-07-18

    Two types of the carnauba wax-based lipophilic matrix tablet using spray-dried granules (SDT) or directly compressible powdered mixtures (DCT) were prepared for sustained release. The model drug was a highly water-soluble potassium citrate and loaded about 74% of the total tablet weight. The SDT slowly eroded and disintegrated during the release study without showing sustained release when the hydrophilic excipients were added. In contrast, the DCT was more efficient for sustained release. The release rate decreased with increasing carnauba wax concentration. In particular, the sustained release rate was markedly pronounced when the lipophilic stearyl alcohol and stearic acid were combined with the carnauba wax. The surface of the intact DCT appeared to be smooth and rusty. The DCT rose to the surface from the bottom of the vessel during the release test, and numerous pores and cracks with no signs of disintegration were also observed after the release test. The release profile was dependent on the formulation composition and preparation method of the matrix tablet. Diffusion-controlled leaching through the channels of the pores and cracks of the lipophilic matrix tablet (DCT) is a key to the sustained release.

  4. Determination of drug lipophilicity by phosphatidylcholine-modified microemulsion high-performance liquid chromatography.

    Science.gov (United States)

    Xuan, Xueyi; Xu, Liyuan; Li, Liangxing; Gao, Chongkai; Li, Ning

    2015-07-25

    A new biomembrane-mimetic liquid chromatographic method using a C8 stationary phase and phosphatidylcholine-modified (PC-modified) microemulsion mobile phase was used to estimate unionized and ionized drugs lipophilicity expressed as an n-octanol/water partition coefficient (logP and logD). The introduction of PC into sodium dodecyl sulfate (SDS) microemulsion yielded a good correlation between logk and logD (R(2)=0.8). The optimal composition of the PC-modified microemulsion liquid chromatography (PC-modified MELC) mobile phase was 0.2% PC-3.0% SDS-6.0% n-butanol-0.8% ethyl acetate-90.0% water (pH 7.0) for neutral and ionized molecules. The interactions between the analytes and system described by this chromatographic method is more similar to biological membrane than the n-octanol/water partition system. The result in this paper suggests that PC-modified MELC can serve as a possible alternative to the shake-flask method for high-throughput unionized and ionized drugs lipophilicity determination and simulation of biological processes. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Some Limits of Biocompatibility Testing for Lipophilic Leachates

    Directory of Open Access Journals (Sweden)

    Anne D. Lucas

    2012-06-01

    Full Text Available Medical device standards recommend using both a polar and non-polar solvent to extract materials prior to in vitro testing. Testing lipophilic extract in cell culture systems is limited by the toxicity of the lipophilic solvents used in extraction. Use of agar overlay and direct contact methods do not directly address the problem of testing for highly lipophilic leachates from device or material extracts. This particular problem was approached by 1 use of hydrotropes, and 2 by sealing the suspended cells in dialysis tubing and placing it directly in oil or media. The use of hydrotropes to eliminate micelle formation and increase the solubility of lipophilic compounds was not useful as the hydrotropes themselves were toxic to the cells at concentrations that significantly increased analyte solubility. Diffusion of hydrophobic compounds from either peanut oil or cell culture media into the dialysis tubing where the test cells in media reside was significantly higher for the cell culture media than the peanut oil. There were significant differences in toxicity for cells in dialysis tubing from devices extracted between peanut oil and media. This study illustrates the importance of examining if cell toxicity due to micelle formation versus that of soluble chemicals for lipophilic extracts.

  6. Removal of technetium from alkaline nuclear-waste media by a solvent-extraction process using crown ethers

    International Nuclear Information System (INIS)

    Bonnesen, P.V.; Presley, D.J.; Haverlock, T.J.; Moyer, B.A.

    1995-01-01

    Crown ethers dissolved in suitably modified aliphatic kerosene diluents can be employed to extract technetium as pertechnetate anion (TcO 4 - ) with good extraction ratios from realistic simulants of radioactive alkaline nitrate waste. The modifiers utilized are non-halogenated and non-volatile, and the technetium can be removed from the solvent by stripping using water. The crown ethers bis-4,4'(5')[(tert-butyl)cyclohexano]-18-crown-6 (di-t-BuCH18C6) and dicyclohexano-18-crown-6 (DCH18C6) provide stronger TcO 4 - extraction than dicyclohexano-21-crown-7 and 4-tert-butylcyclohexano 15-crown-5. Whereas DCH18C6 provides somewhat higher TcO 4 - extraction ratios than the more lipophilic di-t-BuCH18C6 derivative, the latter was selected for further study owing to its lower distribution to the aqueous phase. Particularly good extraction and stripping results were obtained with di-t-BuCH 18C6 at 0.02 M in a 2:1 vol/vol blend of tributyl phosphate and Isopar reg-sign M. Using this solvent, 98.9% of the technetium contained (at 6 x 10 -5 M) in a Double-Shell Slurry Feed (DSSF) Hanford tank waste simulant was removed following two cross-current extraction contacts. Two cross-current stripping contacts with deionized water afforded removal of 99.1% of the technetium from the organic solvent

  7. Discovery of a potent and selective free fatty acid receptor 1 agonist with low lipophilicity and high oral bioavailability

    DEFF Research Database (Denmark)

    Christiansen, Elisabeth; Due-Hansen, Maria E; Urban, Christian

    2013-01-01

    The free fatty acid receptor 1 (FFA1, also known as GPR40) mediates enhancement of glucose-stimulated insulin secretion and is emerging as a new target for the treatment of type 2 diabetes. Several FFA1 agonists are known, but the majority of these suffer from high lipophilicity. We have previously...... reported the FFA1 agonist 3 (TUG-424). We here describe the continued structure-activity exploration and optimization of this compound series, leading to the discovery of the more potent agonist 40, a compound with low lipophilicity, excellent in vitro metabolic stability and permeability, complete oral...

  8. Lipophilic drug transfer between liposomal and biological membranes

    DEFF Research Database (Denmark)

    Fahr, Alfred; van Hoogevest, Peter; Kuntsche, Judith

    2006-01-01

    This review presents the current knowledge on the interaction of lipophilic, poorly water soluble drugs with liposomal and biological membranes. The center of attention will be on drugs having the potential to dissolve in a lipid membrane without perturbing them too much. The degree of interaction...... is described as solubility of a drug in phospholipid membranes and the kinetics of transfer of a lipophilic drug between membranes. Finally, the consequences of these two factors on the design of lipid-based carriers for oral, as well as parenteral use, for lipophilic drugs and lead selection of oral...... lipophilic drugs is described. Since liposomes serve as model-membranes for natural membranes, the assessment of lipid solubility and transfer kinetics of lipophilic drug using liposome formulations may additionally have predictive value for bioavailability and biodistribution and the pharmacokinetics...

  9. Lipophilic extracts from banana fruit residues: a source of valuable phytosterols.

    Science.gov (United States)

    Oliveira, Lúcia; Freire, Carmen S R; Silvestre, Armando J D; Cordeiro, Nereida

    2008-10-22

    The chemical composition of the lipophilic extracts of unripe pulp and peel of banana fruit 'Dwarf Cavendish' was studied by gas chromatography-mass spectrometry. Fatty acids, sterols, and steryl esters are the major families of lipophilic components present in banana tissues, followed by diacylglycerols, steryl glucosides, long chain fatty alcohols, and aromatic compounds. Fatty acids are more abundant in the banana pulp (29-90% of the total amount of lipophilic extract), with linoleic, linolenic, and oleic acids as the major compounds of this family. In banana peel, sterols represent about 49-71% of the lipophilic extract with two triterpenic ketones (31-norcyclolaudenone and cycloeucalenone) as the major components. The detection of high amounts of steryl esters (469-24405 mg/kg) and diacylglycerols (119-878 mg/kg), mainly present in the banana peel extract, explains the increase in the abundance of fatty acids and sterols after alkaline hydrolysis. Several steryl glucosides were also found in significative amounts (273-888 mg/kg), particularly in banana pulp (888 mg/kg). The high content of sterols (and their derivatives) in the 'Dwarf Cavendish' fruit can open new strategies for the valorization of the banana residues as a potential source of high-value phytochemicals with nutraceutical and functional food additive applications.

  10. Retrospective Study of Retention of Stainless Steel Crowns and Pre-veneered Crowns on Primary Anterior Teeth.

    Science.gov (United States)

    Lopez-Loverich, Angela M; Garcia, Maria Minerva; Donly, Kevin J

    2015-01-01

    The purpose of this retrospective chart review was to explore the retention of anterior pre-veneered stainless steel crowns (NuSmile) and conventional stainless steel crowns (3M ESPE) placed on primary anterior teeth. Records for children were reviewed over four years using the electronic record system axiUm. Data collected included child's age at time of crown placement, date of placement, tooth number, type of crown, patient behavior, treatment environment, provider type, crown presence, absence, and cementation success or failure at subsequent recall visits. A total of 637 anterior crowns in children treated with either or both crown types met this study's inclusion criteria. Of these crowns, 483 were NuSmile Signature crowns and 154 were stainless steel crowns. There was a nine percent failure rate for the NuSmile Signature crowns and a seven percent failure rate for the stainless steel crowns. There was no statistically significant difference in crown retention rates between the two groups (P<0.05). A full-coverage restoration that can follow the lifespan of the primary anterior dentition in high-risk children is needed. The results from this study indicate good crown retention rates for both crown types with no statistically significant difference between them (P<0.05).

  11. Adsorptive stripping voltammetry in lipophilic vitamins determination

    Directory of Open Access Journals (Sweden)

    Milan Sýs

    2016-06-01

    Full Text Available The aim of this contribution was to check if adsorptive stripping differential pulse voltammetry (AdSDPV is suitable tool for sensitive simultenous electrochemical detection of lipophilic vitamins. Retinol (vitamin A1, cholecalciferol (vitamin D3, α-tocopherol (vitamin E and phylloquinone (vitamin K1 were selected as representatives. All electrochemical measurements were performed in two separate steps due to the lipophilic character of the analytes. In the first step, an accumulation of lipophilic vitamin on the surface of glassy carbon electrode (GCE was done by immersing working electrode into the aqueous‑acetonitrile solutions (50%, v/v of each vitamin (50.0 µmol.L-1 at 400 rpm for 5 min. In the second one, differential pulse voltammetry of accumulated vitamins was performed in 0.01 mol.L-1 acetate (pH 4.5 buffer at potential step (Estep 5 mV, potential of amplitude (Eampl 25 mV, interval time (t 0.1 s and scan rate (ν 50 mV.s-1. It was observed that electrochemical behaviour of lipophilic vitamins adsorbed on surface of solid GCE in the aqueous electrolyte was very similar to those performed in organic/aqueous electrolyte in literature. Due to reversible electrochemical behaviour of vitamin K1 (phylloquinone/phyllohydroquinone redox couple, it was possible to detect all lipophilic vitamins only in one analysis. Observed values of peak potentials (Ep were sufficiently different for their recognition which was confirmed by the analysis of real sample. The results obtained in this study showed that simultaneous determination of some lipophilic vitamins is possible requiring further optimization study. For this reason, it is necessary to understand this work as an initial step in simultaneous determination of lipophilic vitamins without application of any chromatographic technique.

  12. Does lipophilicity per se induce adjuvant effects?

    DEFF Research Database (Denmark)

    Hansen, Jitka Stilund; Larsen, Søren Thor; Poulsen, Lars K.

    2007-01-01

    Anthopogenically introduced substances and pollutants are suspected to promote sensitization and development of allergic airway diseases, that is, acting as adjuvants. Lipophilicity may serve as an immunological warning signal, promoting adjuvant effects. Whether the lipophilicity of an inhaled...... respiratory patterns were significantly affected in the MP groups. The OVA + Al(OH)3 group had a significantly higher IgG1 and IgE production, as well as higher eosinophil infiltration in the BAL fluid. These studies showed that effects of adjuvants not are necessarily due to their lipophilicity; that is...

  13. Canada’s Evolving Crown: From a British Crown to a “Crown of Maples”

    Directory of Open Access Journals (Sweden)

    Romaniuk Scott Nicholas

    2014-12-01

    Full Text Available This article examines how instruments have changed the Crown of Canada from 1867 through to the present, how this change has been effected, and the extent to which the Canadian Crown is distinct from the British Crown. The main part of this article focuses on the manner in which law, politics, and policy (both Canadian and non-Canadian have evolved a British Imperial institution since the process by which the federal Dominion of Canada was formed nearly 150 years ago through to a nation uniquely Canadian as it exists today. The evolution of the Canadian Crown has taken place through approximately fifteen discrete events since the time of Canadian confederation on July 1, 1867. These fifteen events are loosely categorized into three discrete periods: The Imperial Crown (1867-1930, A Shared Crown (1931-1981, and The Canadian Crown (1982-present.

  14. Dinar-crown banknotes

    OpenAIRE

    Pantelić Svetlana

    2017-01-01

    Dinar-crown banknotes were: ½ dinars (i.e. 2 crowns), 1 dinar (i.e. 4 crowns), 5 dinars (i.e. 20 crowns), 10 dinars (i.e. 40 crowns), 20 dinars (i.e. 80 crowns), 100 dinars (i.e. 400 crowns), and 1000 dinars (i.e. 4000 crowns). The ½- and 1-dinar banknotes are assumed to have been issued in 1919, whereas the other five banknotes, according to one source, were released into circulation on 21.02.1920. Pursuant to the regulations, the replacement of the nostrified crown banknotes by the new crow...

  15. Fracture-resistant monolithic dental crowns.

    Science.gov (United States)

    Zhang, Yu; Mai, Zhisong; Barani, Amir; Bush, Mark; Lawn, Brian

    2016-03-01

    To quantify the splitting resistance of monolithic zirconia, lithium disilicate and nanoparticle-composite dental crowns. Fracture experiments were conducted on anatomically-correct monolithic crown structures cemented to standard dental composite dies, by axial loading of a hard sphere placed between the cusps. The structures were observed in situ during fracture testing, and critical loads to split the structures were measured. Extended finite element modeling (XFEM), with provision for step-by-step extension of embedded cracks, was employed to simulate full failure evolution. Experimental measurements and XFEM predictions were self-consistent within data scatter. In conjunction with a fracture mechanics equation for critical splitting load, the data were used to predict load-sustaining capacity for crowns on actual dentin substrates and for loading with a sphere of different size. Stages of crack propagation within the crown and support substrate were quantified. Zirconia crowns showed the highest fracture loads, lithium disilicate intermediate, and dental nanocomposite lowest. Dental nanocomposite crowns have comparable fracture resistance to natural enamel. The results confirm that monolithic crowns are able to sustain high bite forces. The analysis indicates what material and geometrical properties are important in optimizing crown performance and longevity. Copyright © 2015 Academy of Dental Materials. All rights reserved.

  16. Phenolics and Lipophilized Phenolics as Antioxidants in Fish Oil Enriched Emulsions,

    DEFF Research Database (Denmark)

    Sørensen, Ann-Dorit Moltke; Nielsen, Nina Skall; Jacobsen, Charlotte

    work better as antioxidants in bulk oil, whereas lipophilic compounds are better antioxidants in emulsions. This presentation is an overview of our previous work in the area of fish oil enriched emulsions with antioxidants. Our studies have shown that the lipophilicity of the compounds is not the only...... with increased lipophilicity. Instead a cut-off effect was observed in relation to the alkyl chain length lipophilized to the phenolic compound. Furthermore, the efficacy of lipophilic antioxidants is influenced by the type of food system. Thus, our results show that the antioxidant behavior may not be as simple...

  17. Dynamic root uptake model for neutral lipophilic organics

    DEFF Research Database (Denmark)

    Trapp, Stefan

    2002-01-01

    and output to stem with the transpiration stream plus first-order metabolism and dilution by exponential growth. For chemicals with low or intermediate lipophilicity (log Kow , 2), there was no relevant difference between dynamic model and equilibrium approach. For lipophilic compounds, the dynamic model...

  18. The recent advances on carrier materials for microencapsulating lipophilic cores

    Directory of Open Access Journals (Sweden)

    JIN Minfeng

    2014-12-01

    Full Text Available Lipophilic ingredients,such as polyunsaturated fatty acids,play an important role in industrialized foods to fortify the nutrients.However,these materials are normally sensitive to oxygen,light or heat to be oxidized,and hard to flow and mix within the bulk food due to the hydrophobic nature.Microencapsulation of lipophilic materials could effectively extend their shelf lives,mask unsatisfied flavors,change their physicochemical properties,and enhance the mixing capacities.This work reviewed the different carrier materials applied in microencapsulating the lipophilic ingredients,and discussed their characteristics and effects on encapsulation efficiencies and release profiles of lipophilic cores.

  19. Chemical research of lipophilic fractions of sickle alfalfa herbs

    Directory of Open Access Journals (Sweden)

    S. V. Kovalev

    2013-06-01

    Full Text Available Lipophilic fraction (LF of known medicinal plants are still less studied, despite the fact that they have a unique group of biological active compounds (BAC. The main active substances of LF are chlorophylls, carotenoids, tocopherols, sterols, unsaturated fatty acids, phospholipids, and other bioactive substances that exhibit a wide spectrum of pharmacological action. In this regard, a comprehensive study of advanced plant of flora of Ukraine to increase the assortments of herbal remedies is an urgent problem. The aim of this work was to obtain and chemical research of lipophilic fractions of sickle alfalfa herbs. The alfalfa herb harvested throughout the growing season in Kharkov and Poltava regions in 2011-2012. Lipophilic fraction was obtained by extraction with chloroform in a Soxhlet apparatus. Detection of carotenoids and chlorophylls by thin layer chromatography (TLC on plates of "Silufol" in one-dimensional and two-dimensional variants, the solvent system were: hexane: acetone (6:2 - I way, hexane-acetone (6:4 - II way. Assay of the lipophilic fraction by three-dimensional fluorescence spectroscopy (3DF-spectroscopy was used for the analysis of mixtures containing fluorescent components. 3DF-spectres, that have the appearance of the surface, are characterized by a functions I = f (λexc, λem, recorded in the ultraviolet and visible ranges. Assay of the carotenoids and chlorophylls carried out by spectrophotometry. The reference solution was chloroform. Assay of fatty acids was performed by gas-liquid chromatography (GLC of methyl esters of fatty acids via chromatograph with flame ionization detector "Shimadzu GC-14B". 20.0 g crushed sickle alfalfa herbs were exhaustively extracted with chloroform in a Soxhlet apparatus for produce a lipophilic fractions. The chloroform extract was evaporated in order to remove the extractant. The percentage of lipophilic fraction in the herbs was 7.5%. Quantity of the carotenoids and chlorophylls

  20. determination of lipophilic extractives in ionic liquid extracts

    African Journals Online (AJOL)

    dell

    Chem. 9: 63-69. Freire CSR, Pinto PCR, Santiago AS,. Silvestre AJD, Evtuquin DV and Neto. CP 2006a Comparative study of lipophilic extractives of hardwoods and corresponding ECF bleached kraft pulps. BioResources. 1: 3-17. Freire CSR, Silvestre AJD and Neto CP. 2005. Lipophilic extractives in. Eucalyptus globulus.

  1. Dinar-crown banknotes

    Directory of Open Access Journals (Sweden)

    Pantelić Svetlana

    2017-01-01

    Full Text Available Dinar-crown banknotes were: ½ dinars (i.e. 2 crowns, 1 dinar (i.e. 4 crowns, 5 dinars (i.e. 20 crowns, 10 dinars (i.e. 40 crowns, 20 dinars (i.e. 80 crowns, 100 dinars (i.e. 400 crowns, and 1000 dinars (i.e. 4000 crowns. The ½- and 1-dinar banknotes are assumed to have been issued in 1919, whereas the other five banknotes, according to one source, were released into circulation on 21.02.1920. Pursuant to the regulations, the replacement of the nostrified crown banknotes by the new crown- dinar banknotes started on 3 February 1920 in Serbia and Montenegro and on 16 February 1920 in other parts of the country. All seven denominations of the dinar-crown banknotes were being withdrawn from circulation throughout a lengthy period of time from 21 February 1921 until May 1934. The first to be withdrawn were the 20-dinar banknotes, from 1 February to 30 April 1921, then the 5-dinar banknotes, from 20 July to 20 November 1922, and the 10-dinar banknotes, from 10 February to 10 June 1924. The 100-dinar (400-crown and 1000-dinar (4000-crown banknotes remained in circulation the longest. The withdrawal of the 100- and 1000-dinar banknotes started in 1929 and lasted until 25 May 1934. The 1924 rulebook on minting coins of ½, 1 and 2 dinars precisely defines their withdrawal from circulation and replacement by minted coins within one year after the last batch of minted coins gets released into circulation. However, in 1927 the decree of the Minister of Finance prescribed that the remaining paper banknotes be withdrawn from circulation on 30 September 1927 by being replaced by the metal coins of the same denominations.

  2. Highly selective Ba2+ separations with acyclic, lipophilic di-[N-(X)sulfonyl carbamoyl] polyethers.

    Science.gov (United States)

    Elshani, Sadik; Chun, Sangki; Amiri-Eliasi, Bijan; Bartsch, Richard A

    2005-01-14

    New lipophilic acyclic polyethers with two N-(X)sulfonyl carbamoyl groups of "tunable" acidity exhibit remarkable selectivity for Ba2+ over other alkaline earth metal ions in competitive solvent extraction and transport across polymer inclusion membranes.

  3. Associations of Drug Lipophilicity and Extent of Metabolism with Drug-Induced Liver Injury.

    Science.gov (United States)

    McEuen, Kristin; Borlak, Jürgen; Tong, Weida; Chen, Minjun

    2017-06-22

    Drug-induced liver injury (DILI), although rare, is a frequent cause of adverse drug reactions resulting in warnings and withdrawals of numerous medications. Despite the research community's best efforts, current testing strategies aimed at identifying hepatotoxic drugs prior to human trials are not sufficiently powered to predict the complex mechanisms leading to DILI. In our previous studies, we demonstrated lipophilicity and dose to be associated with increased DILI risk and, and in our latest work, we factored reactive metabolites into the algorithm to predict DILI. Given the inconsistency in determining the potential for drugs to cause DILI, the present study comprehensively assesses the relationship between DILI risk and lipophilicity and the extent of metabolism using a large published dataset of 1036 Food and Drug Administration (FDA)-approved drugs by considering five independent DILI annotations. We found that lipophilicity and the extent of metabolism alone were associated with increased risk for DILI. Moreover, when analyzed in combination with high daily dose (≥100 mg), lipophilicity was statistically significantly associated with the risk of DILI across all datasets ( p < 0.05). Similarly, the combination of extensive hepatic metabolism (≥50%) and high daily dose (≥100 mg) was also strongly associated with an increased risk of DILI among all datasets analyzed ( p < 0.05). Our results suggest that both lipophilicity and the extent of hepatic metabolism can be considered important risk factors for DILI in humans, and that this relationship to DILI risk is much stronger when considered in combination with dose. The proposed paradigm allows the convergence of different published annotations to a more uniform assessment.

  4. Assessment of the chromatographic lipophilicity of eight cephalosporins on different stationary phases.

    Science.gov (United States)

    Dąbrowska, Monika; Starek, Małgorzata; Komsta, Łukasz; Szafrański, Przemysław; Stasiewicz-Urban, Anna; Opoka, Włodzimierz

    2017-04-01

    The retention behaviors were investigated for a series of eight cephalosporins in thin-layer chromatography (TLC) using stationary phases of RP-2, RP-8, RP-18, NH 2 , DIOL, and CN chemically bonded silica gel. Additionally, various binary mobile phases (water/methanol and water/acetone) were used in different volume proportions. The retention behavior of the analyzed molecules was defined by R M0 constant. In addition, reversed phase high performance liquid chromatography (RP-HPLC) was performed in lipophilicity studies by using immobilized artificial membrane (IAM) stationary phase. Obtained chromatographic data (R M0 and logk' IAM ) were correlated with the lipophilicity, expressed as values of the log calculated (logP calc ) and experimental (logP exp(shake-flask) ) partition coefficient. Principal component analysis (PCA) was applied in order to obtain an overview of similarity or dissimilarity among the analyzed compounds. Hierarchical cluster analysis (HCA) was performed to compare the separation characteristics of the applied stationary phases. This study was undertaken to identify the best chromatographic system and chromatographic data processing method to enable the prediction of logP values. A comprehensive chromatographic investigation into the retention of the analyzed cephalosporins revealed a similar behavior on RP-18, RP-8 and CN stationary phases. The weak correlations obtained between experimental and certain computed lipophilicity indices revealed that R M0 and PC1/RM are relevant lipophilicity parameters and the RP-8, CN and RP-18 plates are appropriate stationary phases for lipophilicity investigation, whereas computational approaches still cannot fully replace experimentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Heuristic lipophilicity potential for computer-aided rational drug design

    Science.gov (United States)

    Du, Qishi; Arteca, Gustavo A.; Mezey, Paul G.

    1997-09-01

    In this contribution we suggest a heuristic molecular lipophilicitypotential (HMLP), which is a structure-based technique requiring noempirical indices of atomic lipophilicity. The input data used in thisapproach are molecular geometries and molecular surfaces. The HMLP is amodified electrostatic potential, combined with the averaged influences fromthe molecular environment. Quantum mechanics is used to calculate theelectron density function ρ(r) and the electrostatic potential V(r), andfrom this information a lipophilicity potential L(r) is generated. The HMLPis a unified lipophilicity and hydrophilicity potential. The interactions ofdipole and multipole moments, hydrogen bonds, and charged atoms in amolecule are included in the hydrophilic interactions in this model. TheHMLP is used to study hydrogen bonds and water-octanol partitioncoefficients in several examples. The calculated results show that the HMLPgives qualitatively and quantitatively correct, as well as chemicallyreasonable, results in cases where comparisons are available. Thesecomparisons indicate that the HMLP has advantages over the empiricallipophilicity potential in many aspects. The HMLP is a three-dimensional andeasily visualizable representation of molecular lipophilicity, suggested asa potential tool in computer-aided three-dimensional drug design.

  6. Crown-rise and crown-length dynamics: applications to loblolly pine

    Science.gov (United States)

    Harry T. Valentine; Ralph L. Amateis; Jeffrey H. Gove; Annikki. Makela

    2013-01-01

    The original crown-rise model estimates the average height of a crown-base in an even-aged mono-species stand of trees. We have elaborated this model to reduce bias and prediction error, and to also provide crown-base estimates for individual trees. Results for the latter agree with a theory of branch death based on resource availability and allocation.We use the...

  7. Chromatographic lipophilicity determination using large volume injections of the solvents non-miscible with the mobile phase.

    Science.gov (United States)

    Sârbu, Costel; Naşcu-Briciu, Rodica Domnica; Casoni, Dorina; Kot-Wasik, Agata; Wasik, Andrzej; Namieśnik, Jacek

    2012-11-30

    A new perspective in the lipophilicity evaluation through RP-HPLC is permitted by analysis of the retention factor (k) obtained by injecting large volumes of test samples prepared in solvents immiscible with mobile phase. The experiment is carried out on representative groups of compounds with increased toxicity (mycotoxins and alkaloids) and amines with important biological activity (naturally occurring monoamine compounds and related drugs), which are covering a large interval of lipophilicity. The stock solution of each compound was prepared in hexane and the used mobile phases were mixtures of methanol or acetonitrile and water, in suited volume ratio. The injected volume was between 10 and 100 μL, while the used stationary phases were RP-18 and RP-8. On both reverse stationary phases the retention factors were linearly decreasing while the injection volume was increasing. In all cases, the linear models were highly statistically significant. On the basis of the obtained results new lipophilicity indices were purposed and discussed. The developed lipophilicity indices and the computationally expressed ones are correlated at a high level of statistical significance. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. RP TLC-based lipophilicity assessment of some natural and synthetic coumarins

    Energy Technology Data Exchange (ETDEWEB)

    Rabtti, El Hadi M.A.; Natic, Maja M.; Milojkovic-Opsenica, Dusanka M.; Trifkovic, Jelena D.; Vuckovic, Ivan M.; Tesic, Zivoslav Lj., E-mail: ztesic@chem.bg.ac.rs [Faculty of Chemistry, University of Belgrade, Belgrade (Serbia); Vajs, Vlatka E. [Institute of Chemistry, Technology and Metallurgy, University of Belgrade, Belgrade (Serbia)

    2012-03-15

    The lipophilic character of twelve coumarins was investigated by reversed-phase thin-layer chromatography (RP TLC) on RP-18 silica. The three different binary solvent systems composed of water and organic modifier (methanol, tetrahydrofuran or acetonitrile) were used in order to determine retention parameter (R{sub M}{sup 0}) and octanol-water partition coefficient (log P{sub OW})as a measure of the lipophilicity of the tested compounds. Lipophilicity parameter (log P{sub OW}) was experimentally determined using eight standard solutes with known log P{sub OW} values which were analyzed under the same chromatographic conditions as the target substances. Lipophilicity parameters together with 2D molecular descriptors were subjected to the multivariate statistical analysis (principal component analysis (PCA) and partial least square (PLS) regression) in order to reveal the most influential factors governing the retention, i.e., lipophilicity of the investigated compounds. The quantitative structure-retention relationship models reveal the importance of descriptors which describe the size and the shape of the molecule as well as their polar properties. (author)

  9. Coast redwood live crown and sapwood

    Science.gov (United States)

    John-Pascal Berrill; Jesse L. Deffress; Jessica M. Engle

    2012-01-01

    Understanding crown rise and sapwood taper will help meet management objectives such as producing long branch-free boles for clear wood and old-growth restoration, or producing sawlogs with a high proportion of heartwood. Coast redwood (Sequoia sempervirens) tree crown ratio data were collected 20 years after partial harvesting in a 65-year-old second growth stand....

  10. Radiosensitization of hypoxic bacterial cells by nitroimidazoles of low lipophilicity: steady-state and rapid-mix studies

    International Nuclear Information System (INIS)

    Anderson, R.F.; Patel, K.B.; Sehmi, D.S.

    1981-01-01

    Radiosensitization of hypoxic bacterial cells by five 2-nitroimidazoles, with similar reduction potentials to misonidazole but having lower lipophilicites, has been measured in Escherichia coli AB 1157 and Streptococcus lactis 712. Sensitization efficiency progressively decreased with decreasing lepophilicity in E. coli but not in S. lactis. This difference is discussed in terms of the differing membrane properties of the two bacteria; E. coli resembled a multicompartment model, as would also be expected with mammalian cells. Rapid-mix experiments are described which show that the radiosensitization observed after experiments are described which show that the radiosensitization observed after preirradiation contact times between ca. 3 and 30 msec is dependent on the lipophilicity of the sensitizer, higher lipophilicity resulting in a lower contact time being required for radiosensitization. This result and the observation that a highly lipophilic compound affects only half the full oxygen enhancement level after short contact times suggest that part of the sensitization process occurs in a lipophilic compartment of the cell

  11. The crown splash

    Science.gov (United States)

    Deegan, Robert; Brunet, Philippe; Eggers, Jens

    2008-11-01

    The impact of a drop onto a liquid layer and the subsequent splash has important implications for diverse physical processes such as air-sea gas transfer, cooling, and combustion. In the crown splash parameter regime, the splash pattern is highly regular. We focus on this case as a model for the mechanism that leads to secondary droplets, and thus explain the drop size distribution resulting from the splash. We show that the mean number of secondary droplets is determined by the most unstable wavelength of the Rayleigh-Plateau instability. Variations from this mean are governed by the width of the spectrum. Our results for the crown splash will provide the basis for understanding more complicated splashes.

  12. Synthetic lipophilic antioxidant BO-653 suppresses HCV replication.

    Science.gov (United States)

    Yasui, Fumihiko; Sudoh, Masayuki; Arai, Masaaki; Kohara, Michinori

    2013-02-01

    The influence of the intracellular redox state on the hepatitis C virus (HCV) life cycle is poorly understood. This study demonstrated the anti-HCV activity of 2,3-dihydro-5-hydroxy-2,2-dipentyl-4,6-di-tert-butylbenzofuran (BO-653), a synthetic lipophilic antioxidant, and examined whether BO-653's antioxidant activity is integral to its anti-HCV activity. The anti-HCV activity of BO-653 was investigated in HuH-7 cells bearing an HCV subgenomic replicon (FLR3-1 cells) and in HuH-7 cells infected persistently with HCV (RMT-tri cells). BO-653 inhibition of HCV replication was also compared with that of several hydrophilic and lipophilic antioxidants. BO-653 suppressed HCV replication in FLR3-1 and RMT-tri cells in a concentration-dependent manner. The lipophilic antioxidants had stronger anti-HCV activities than the hydrophilic antioxidants, and BO-653 displayed the strongest anti-HCV activity of all the antioxidants examined. Therefore, the anti-HCV activity of BO-653 was examined in chimeric mice harboring human hepatocytes infected with HCV. The combination treatment of BO-653 and polyethylene glycol-conjugated interferon-α (PEG-IFN) decreased serum HCV RNA titer more than that seen with PEG-IFN alone. These findings suggest that both the lipophilic property and the antioxidant activity of BO-653 play an important role in the inhibition of HCV replication. Copyright © 2012 Wiley Periodicals, Inc.

  13. Lipophilization and MS characterization of the main anthocyanins purified from hibiscus flowers.

    Science.gov (United States)

    Grajeda-Iglesias, Claudia; Salas, Erika; Barouh, Nathalie; Baréa, Bruno; Figueroa-Espinoza, Maria Cruz

    2017-09-01

    Hibiscus sabdariffa flowers represent an interesting source of anthocyanins, one of the most important plant pigments, which are responsible of the intense red color of the calyces, and have potential as natural colorants for food applications. Nevertheless, anthocyanins are highly hydrosoluble and unstable compounds. On this basis, the aim of this work was to increase the lipophilicity of the hibiscus anthocyanins by lipophilization, in order to obtain amphiphilic colorants, which could be easily incorporated in lipid-rich food matrices. Octanoyl derivatives of delphinidin-3-O-sambubioside and cyanidin-3-O-sambubioside were chemically obtained for the first time, and characterized by means of HPLC-ESI-MS data. Copyright © 2017. Published by Elsevier Ltd.

  14. Assessment of crown angulations, crown inclinations, and tooth size discrepancies in a South Indian population

    Directory of Open Access Journals (Sweden)

    Geeta Maruti Doodamani

    2011-01-01

    Full Text Available Aims and Objective: The aim of this study was to assess crown angulations, crown inclinations, and tooth size discrepancy in a sample population from Davangere, South India. Materials and Methods: One hundred adults (50 male and 50 female of age 18-30 years, with Angle′s class I ideal occlusion and balanced profiles, were selected for the study. Study models were prepared and crown angulations and crown inclinations were measured using a customized protractor device. Bolton′s analysis was used to measure the tooth size discrepancies. Results: Maxillary and mandibular teeth had less crown angulations. Maxillary and mandibular incisors and maxillary molars showed increased crown inclinations, whereas mandibular molars and premolars had less crown inclinations than the original Andrews sample. The mean maxillary and mandibular tooth size ratios, overall and anterior, were similar to Bolton′s ratios. Conclusions: The finding of this study indicates that there are possible racial and ethnic factors contributing to variations in crown angulations and crown inclinations.

  15. Effect of lipophilization of dihydrocaffeic acid on its antioxidative properties in fish oil enriched emulsion

    DEFF Research Database (Denmark)

    Sørensen, Ann-Dorit Moltke; de Diego, Sara; Petersen, Lone Kristine

    oxidation than PUFAs from vegetable oils due to their highly polyunsaturated nature, it is necessary to develop methods to protect these PUFAs. Many food systems are emulsions. Due to the so-called polar paradox phenomenon, hydrophilic antioxidants may in many cases be better antioxidants in bulk oil than...... lipophilic compounds, whereas lipophilic antioxidants are more efficient than hydrophilic antioxidants in emulsions. This phenomenon has been explained by the affinity of the compounds towards the different phases in bulk oil and emulsions. The hydrophilic character of many naturally occurring antioxidants...... that generally, lipophilized dihydrocaffeic acid and rutin increased the oxidative stability of o/w emulsions and fish oil enriched milk compared with their parent compound. The results supported a cut-off effect in relation to the acyl chain length esterified to the phenolic compound. Octyl dihydrocaffeate (C8...

  16. Alternative measures of lipophilicity: from octanol-water partitioning to IAM retention.

    Science.gov (United States)

    Giaginis, Costas; Tsantili-Kakoulidou, Anna

    2008-08-01

    This review describes lipophilicity parameters currently used in drug design and QSAR studies. After a short historical overview, the complex nature of lipophilicity as the outcome of polar/nonpolar inter- and intramolecular interactions is analysed and considered as the background for the discussion of the different lipophilicity descriptors. The first part focuses on octanol-water partitioning of neutral and ionisable compounds, evaluates the efficiency of predictions and provides a short description of the experimental methods for the determination of distribution coefficients. A next part is dedicated to reversed-phase chromatographic techniques, HPLC and TLC in lipophilicity assessment. The two methods are evaluated for their efficiency to simulate octanol-water and the progress achieved in the refinement of suitable chromatographic conditions, in particular in the field of HPLC, is outlined. Liposomes as direct models of biological membranes are examined and phospolipophilicity is compared to the traditional lipophilicity concept. Difficulties associated with liposome-water partitioning are discussed. The last part focuses on Immobilised Artificial Membrane (IAM) chromatography as an alternative which combines membrane simulation with rapid measurements. IAM chromatographic retention is compared to octanol-water and liposome-water partitioning as well as to reversed-phase retention and its potential to predict biopartitioning and biological activities is discussed.

  17. Lipophilic Toxins in WA - Clear and present danger: monitoring and management of lipophilic shellfish toxins in Washington State

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Lipophilic shellfish toxins comprise an extensive suite of compounds including those associated with the human syndromes known as diarrhetic shellfish poisoning...

  18. Crown releasing of red maple poles to shorten high-quality sawlog rotations

    Science.gov (United States)

    Gayne G. Erdmann; Ralph M., Jr. Peterson; Robert R. Orberg

    1985-01-01

    The effects of six crown-release treatments on growth and bole quality development of 54-year-old dominant, codominant, and intermediate red maples (Acer rubrum L.) were evaluated on a good red maple site (site index = 19.3 mat 50 years) in upper Michigan. Results showed that crown release stimulated the growth of dominants, codominants, and strong...

  19. Assessing the lipophilicity of fragments and early hits

    Science.gov (United States)

    Mortenson, Paul N.; Murray, Christopher W.

    2011-07-01

    A key challenge in many drug discovery programs is to accurately assess the potential value of screening hits. This is particularly true in fragment-based drug design (FBDD), where the hits often bind relatively weakly, but are correspondingly small. Ligand efficiency (LE) considers both the potency and the size of the molecule, and enables us to estimate whether or not an initial hit is likely to be optimisable to a potent, druglike lead. While size is a key property that needs to be controlled in a small molecule drug, there are a number of additional properties that should also be considered. Lipophilicity is amongst the most important of these additional properties, and here we present a new efficiency index (LLEAT) that combines lipophilicity, size and potency. The index is intuitively defined, and has been designed to have the same target value and dynamic range as LE, making it easily interpretable by medicinal chemists. Monitoring both LE and LLEAT should help both in the selection of more promising fragment hits, and controlling molecular weight and lipophilicity during optimisation.

  20. Preparation and performance of lipophilic α-zirconium phosphate with high thermal stability and its application in thermal-plastic polymers

    Directory of Open Access Journals (Sweden)

    Ya Du

    2015-10-01

    Full Text Available To prepare lipophilic α-zirconium phosphate with high grafting ratio and thermal stability (OZrP-HT and explore its potential application in thermal-plastic polymers, a novel method was developed by surface lipophilicity enhancement strategy. The commercial α-zirconium phosphate (α-ZrP was pre-intercalated by n-propylamine (PA and grafted by silane coupling agents. Then the pre-intercalated PA was removed by heat-treatment, and the obtained OZrP-HT was utilized to fabricate the phosphorous-containing polyester (P-co-PET/OZrP-HT nanocomposites by melt-blending method. The prepared OZrP-HT and P-co-PET/OZrP-HT nanocomposites were characterized by Wide Angle X-ray Diffraction (WAXD, Fourier Transform Infrared Spectroscopy (FTIR, Thermogravimetric Analysis (TGA, Transmission Electron Microscope (TEM, etc. The results show that OZrP-HT with high grafting ratio (13.78 wt% and thermal stability (Tonset=368 °C was successfully prepared via this novel method and was uniformly intercalated by P-co-PET molecular chains. OZrP-HT had no significant effect on the fiber processability of P-co-PET polymer, and flame retardant properties of (P-co-PET/OZrP-HT nanocomposites were improved. This method may be suitable for organic modification of general inorganic layered compounds and could extend the potential applications in thermo-plastic polymers.

  1. Crown condition dynamics of oak in southern Sweden 1988-1999.

    Science.gov (United States)

    Drobyshev, Igor; Anderson, Stefan; Sonesson, Kerstin

    2007-11-01

    Crown defoliation of oak (Quercus robur and Q. petraea) was analysed in 808 trees during three forest condition surveys (1988, 1993, and 1999) in the southern Sweden. From 1988 to 1999 crown defoliation increased by more than 20%. Changes in crown defoliation were related to the pH in the upper 20-30 cm of the mineral soils, which was closely connected to other measures of soil fertility (cation exchange capacity, CEC and C/N ratio). Trees growing on soils with a high pH (> or =4.00, in BaCl2 filtrate), high CEC and low C/N ratio had significantly lower crown defoliation than trees growing on more acid soils (pH trees with respect to crown defoliation, indicating that decline in crown condition was not due to an age-related increase in crown transparency. Considering only trees younger than 100 years, a significant interaction was observed between changes in crown defoliation and soil pH. Trees younger than 100 years old growing on more acidic soils had a greater increase in crown transparency than trees on more basic soils between 1988 and 1999. Trees > or =100 years old had significantly higher defoliation on more acidic than on more basic soils, however defoliation dynamics of these trees over 1988-99 was not related to soil acidity. Two biotic agents (insect and fungal leaf infections) evaluated in this study did not prove to be important drivers of defoliation dynamics.

  2. Lipophilic Polycation Vehicles Display High Plasmid DNA Delivery to Multiple Cell Types.

    Science.gov (United States)

    Wu, Yaoying; Smith, Adam E; Reineke, Theresa M

    2017-08-16

    A class of cationic poly(alkylamidoamine)s (PAAAs) containing lipophilic methylene linkers were designed and examined as in vitro plasmid DNA (pDNA) delivery agents. The PAAAs were synthesized via step-growth polymerization between a diamine monomer and each of four different diacid chloride monomers with varying methylene linker lengths, including glutaryl chloride, adipoyl chloride, pimeloyl chloride, and suberoyl chloride, which served to systematically increase the lipophilicity of the polymers. The synthesized polymers successfully complexed with pDNA in reduced serum medium at N/P ratios of 5 and greater, resulting in polyplexes with hydrodynamic diameters of approximately 1 μm. These polyplexes were tested for in vitro transgene expression and cytotoxicity using HDFa (human dermal fibroblast), HeLa (human cervical carcinoma), HMEC (human mammary epithelial), and HUVEC (human umbilical vein endothelial) cells. Interestingly, select PAAA polyplex formulations were found to be more effective than Lipofectamine 2000 at promoting transgene expression (GFP) while maintaining comparable or higher cell viability. Transgene expression was highest in HeLa cells (∼90% for most formulations) and lowest in HDFa cells (up to ∼20%) as measured by GFP fluorescence. In addition, the cytotoxicity of PAAA polyplex formulations was significantly increased as the molecular weight, N/P ratio, and methylene linker length were increased. The PAAA vehicles developed herein provide a new delivery vehicle design strategy of displaying attributes of both polycations and lipids, which show promise as a tunable scaffold for refining the structure-activity-toxicity profiles for future genome editing studies.

  3. Elliptic Fourier analysis of crown shapes in Quercus petraea trees

    Directory of Open Access Journals (Sweden)

    Ovidiu Hâruţa

    2011-02-01

    Full Text Available Shape is a fundamental morphological descriptor, significant in taxonomic research as well as in ecomorphology, one method of estimation being from digitally processed images. In the present study, were analysed shapes of Q. petraea crowns, pertaining to five different stem diameter classes, from three similar stands. Based on measurements on terrestrial digital vertical photos, crown size analysis was performed and correlations between crown and stem variables were tested. Linear regression equations between crown volumes and dbh, and crown volumes and stem volumes were derived, explaining more than half of data variability. Employment of elliptic Fourier analysis (EFA, a powerful analysis tool, permitted the extraction of the mean shape from crowns, characterized by high morphological variability. The extracted, most important, coefficients were used to reconstruct the average shape of the crowns, using Inverse Fourier Transform. A mean shape of the crown, corresponding to stand conditions in which competition is added as influential shaping factor, aside genetic program of the species, is described for each stem diameter class. Crown regions with highest shape variability, from the perspective of stage developmentof the trees, were determined. Accordingly, the main crown shape characteristics are: crown elongation, mass center, asymmetry with regard to the main axis, lateral regions symmetrical and asymmetrical variations.

  4. Elliptic Fourier analysis of crown shapes in Quercus petraea trees

    Directory of Open Access Journals (Sweden)

    Ovidiu Hâruţa

    2011-06-01

    Full Text Available Shape is a fundamental morphological descriptor, significant in taxonomic research as well as in ecomorphology, one method of estimation being from digitally processed images. In the present study, were analysed shapes of Q. petraea crowns, pertaining to five different stem diameter classes, from three similar stands. Based on measurements on terrestrial digital vertical photos, crown size analysis was performed and correlations between crown and stem variables were tested. Linear regression equations between crown volumes and dbh, and crown volumes and stem volumes were derived, explaining more than half of data variability. Employment of elliptic Fourier analysis (EFA, a powerful analysis tool, permitted the extraction of the mean shape from crowns, characterized by high morphological variability. The extracted, most important, coefficients were used to reconstruct the average shape of the crowns, using Inverse Fourier Transform. A mean shape of the crown, corresponding to stand conditions in which competition is added as influential shaping factor, aside genetic program of the species, is described for each stem diameter class. Crown regions with highest shape variability, from the perspective of stage development of the trees, were determined. Accordingly, the main crown shape characteristics are: crown elongation, centroid position, asymmetry with regard to the main axis, lateral regions symmetrical and asymmetrical variations. 

  5. Modified Folin-Ciocalteu antioxidant capacity assay for measuring lipophilic antioxidants.

    Science.gov (United States)

    Berker, Kadriye Isil; Ozdemir Olgun, F Ayca; Ozyurt, Dilek; Demirata, Birsen; Apak, Resat

    2013-05-22

    The Folin-Ciocalteu (FC) method of performing a total phenolics assay, originally developed for protein determination, has recently evolved as a total antioxidant capacity assay but was found to be incapable of measuring lipophilic antioxidants due to the high affinity of the FC chromophore, that is, multivalent-charged phospho-tungsto-molybdate(V), toward water. Thus, the FC method was modified and standardized so as to enable simultaneous measurement of lipophilic and hydrophilic antioxidants in NaOH-added isobutanol-water medium. Optimal conditions were as follows: dilution ratio of aqueous FC reagent with iso-BuOH (1:2, v/v), final NaOH concentration of 3.5 × 10(-2) M, reaction time of 20 min, and maximum absorption wavelength of 665 nm. The modified procedure was successfully applied to the total antioxidant capacity assay of trolox, quercetin, ascorbic acid, gallic acid, catechin, caffeic acid, ferulic acid, rosmarinic acid, glutathione, and cysteine, as well as of lipophilic antioxidants such as α-tocopherol (vitamin E), butylated hydroxyanisole, butylated hydroxytoluene, tertiary butylhydroquinone, lauryl gallate, and β-carotene. The modified FC method reliably quantified ascorbic acid, whereas the conventional method could not. The modified method was reproducible and additive in terms of total antioxidant capacity values of constituents of complex mixtures such as olive oil extract and herbal tea infusion. The trolox equivalent antioxidant capacities of the tested antioxidant compounds correlated well with those found by the Cupric Reducing Antioxidant Capacity reference method.

  6. Lipophilic phytochemicals from banana fruits of several Musa species.

    Science.gov (United States)

    Vilela, Carla; Santos, Sónia A O; Villaverde, Juan J; Oliveira, Lúcia; Nunes, Alberto; Cordeiro, Nereida; Freire, Carmen S R; Silvestre, Armando J D

    2014-11-01

    The chemical composition of the lipophilic extract of ripe pulp of banana fruit from several banana cultivars belonging to the Musa acuminata and Musa balbisiana species (namely 'Chinese Cavendish', 'Giant Cavendish', 'Dwarf Red', 'Grand Nain', 'Eilon', 'Gruesa', 'Silver', 'Ricasa', 'Williams' and 'Zelig') was studied by gas chromatography-mass spectrometry for the first time. The banana cultivars showed similar amounts of lipophilic extractives (ca. 0.4% of dry material weight) as well as qualitative chemical compositions. The major groups of compounds identified in these fractions were fatty acids and sterols making up 68.6-84.3% and 11.1-28.0%, respectively, of the total amount of lipophilic components. Smaller amounts of long chain aliphatic alcohols and α-tocopherol were also identified. These results are a relevant contribution for the valorisation of these banana cultivars as sources of valuable phytochemicals (ω-3 and ω-6 fatty acids, and sterols) with well-established beneficial nutritional and health effects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Effect of posterior crown margin placement on gingival health.

    Science.gov (United States)

    Reitemeier, Bernd; Hänsel, Kristina; Walter, Michael H; Kastner, Christian; Toutenburg, Helge

    2002-02-01

    The clinical impact of posterior crown margin placement on gingival health has not been thoroughly quantified. This study evaluated the effect of posterior crown margin placement with multivariate analysis. Ten general dentists reviewed 240 patients with 480 metal-ceramic crowns in a prospective clinical trial. The alloy was randomly selected from 2 high gold, 1 low gold, and 1 palladium alloy. Variables were the alloy used, oral hygiene index score before treatment, location of crown margins at baseline, and plaque index and sulcus bleeding index scores recorded for restored and control teeth after 1 year. The effect of crown margin placement on sulcular bleeding and plaque accumulation was analyzed with regression models (Prisk of bleeding at intrasulcular posterior crown margins was approximately twice that at supragingival margins. Poor oral hygiene before treatment and plaque also were associated with sulcular bleeding. Facial sites exhibited a lower probability of sulcular bleeding than lingual surfaces. Type of alloy did not influence sulcular bleeding. In this study, placement of crown margins was one of several parameters that affected gingival health.

  8. Actinide/crown ether chemistry

    International Nuclear Information System (INIS)

    Benning, M.M.

    1988-01-01

    A structural survey of actinide/crown ether compounds was conducted in order to investigate the solid state chemistry of these complexes. Several parameters - the metal size, crown type, counterion, solvent systems and reaction and crystallization conditions - were varied to correlate their importance in complexation. Under atmospheric conditions, two types of complexes were isolated, those containing only hydrogen-bonded crown interactions and instances where the crown interacts directly with the metal center. In both cases, water seems to play a very important role. When coordinated to the metal, water molecules exhibit the necessary donor properties required for the formation of hydrogen-bonded contacts. The water molecules also provide fierce competition with the crown ethers for metal-binding sites and in most cases prohibit the formation of complexes in which direct metal-ligand association exists. The results of this study indicate that direct interaction between the metal atoms and the crown ethers, in the presence of water, can only occur with polyether conformations which limit the steric replusions within the metal coordination sphere

  9. IPS Empress crown system: three-year clinical trial results.

    Science.gov (United States)

    Sorensen, J A; Choi, C; Fanuscu, M I; Mito, W T

    1998-02-01

    The IPS Empress system is a highly esthetic hot pressed glass ceramic material for fabrication of single crowns. Adhesive cementation of the system not only contributes to the esthetics but is necessary for increased strength of the crown. The purpose of this prospective clinical trials was to evaluate the longevity of 75 adhesively cemented Empress full crowns. An additional aim was to assess the adhesive cementation methodology and potential side effects. At the three-year point, one molar crown fractured for a 1.3 percent failure rate. The resin cementation technique that was employed exhibited a low incidence of microleakage with few clinical side effects. There was a 5.6 percent incidence of post-cementation sensitivity, with all symptoms subsiding by eight weeks. None of the crowns in the study required endodontic therapy.

  10. Reduction of lipophilic extractives in mechanical pulps; Mekaanisen massan uuteainepitoisuuden alentaminen - EKT 07

    Energy Technology Data Exchange (ETDEWEB)

    Edelmann, K. [VTT Energy, Jyvaeskylae (Finland)

    1998-12-31

    Adsorption of lipophilic extractives released from wood to various filtrates and pressed fractions in the production of thermomechanical pulp on various inorganic substrates has been studied. Both commercial and experimental adsorbents were used. Equilibrium concentrations of lipophilic extractives were determined. Best adsorption results were achieved with talcum and cationized kaolin. Adsorption behaviour of Al2O3 granulate was varied with respect to surface charge and surface energy. In addition to adsorption, oxidation of lipophilic extractives through ozonation and cavitation was studied. In the oxidation studies also other compounds than lipophilic extractives should be followed in order to determine the chemical changes of the process water. The adsorption process is economically more feasible, if the concentration of lipophilic extractives were four to five times higher than the present value 50 mg/l. However more work has to be directed to the development of production methods of the adsorbent itself. Dynamics of the adsorption process should closely be studied. Combined adsorption and ozonation especially in the presence of an oxidation catalyst might be an interesting topic for further studies. (orig.)

  11. Reduction of lipophilic extractives in mechanical pulps; Mekaanisen massan uuteainepitoisuuden alentaminen - EKT 07

    Energy Technology Data Exchange (ETDEWEB)

    Edelmann, K [VTT Energy, Jyvaeskylae (Finland)

    1999-12-31

    Adsorption of lipophilic extractives released from wood to various filtrates and pressed fractions in the production of thermomechanical pulp on various inorganic substrates has been studied. Both commercial and experimental adsorbents were used. Equilibrium concentrations of lipophilic extractives were determined. Best adsorption results were achieved with talcum and cationized kaolin. Adsorption behaviour of Al2O3 granulate was varied with respect to surface charge and surface energy. In addition to adsorption, oxidation of lipophilic extractives through ozonation and cavitation was studied. In the oxidation studies also other compounds than lipophilic extractives should be followed in order to determine the chemical changes of the process water. The adsorption process is economically more feasible, if the concentration of lipophilic extractives were four to five times higher than the present value 50 mg/l. However more work has to be directed to the development of production methods of the adsorbent itself. Dynamics of the adsorption process should closely be studied. Combined adsorption and ozonation especially in the presence of an oxidation catalyst might be an interesting topic for further studies. (orig.)

  12. Selective decontamination of cesium and strontium from evaporation concentrates of spent fuel reprocessing plants with crown ethers by transport through supported liquid membranes

    International Nuclear Information System (INIS)

    Casas i Garcia, J.

    1993-01-01

    Reprocessing operations lead to the production of radioactive medium activity liquid waste which is treated by evaporation and solutions of very high salinity are thus formed. The concentrates from reprocessing plant evaporators have to be stored in geological storage sites in view of their strong caesium, strontium and actinides activity. These elements, contained in acid and high sodium nitrate content liquid waste, are removed by means of selective extractants, using the supported liquid membrane technique (SLM), which allows them to be stored in surface sites, the actinides and long-life fission products being respectively recycled and concentrated into reduced volumes. The removal of the actinides is done by means of an Octyl N.N Diisobutyl Carbamoyl Methyl Phosphine Oxide (C.M.P.O.) based liquid membrane, whereas the removal of the caesium and strontium involves crown ethers. Supported liquid membranes (S.L.M.s) have the advantage of implementing very small quantities of extractant, but they generally have poor stability. The extractant, the diluent and the phase modifier impregnating the membrane play a vital role in SLM stability; the support also affects stability by its nature and geometry. For the extraction of strontium, the most lipophilic extractant, DtBu 18 C 6, enables higher strontium transfer kinetics to be attained. As regards caesium, the extremely lipophilic nDec B21 C7 is the most efficient. Caesium cannot be quantitatively removed, due to the competition of the very high content of sodium ions in the concentrate. Stable membranes are obtained with DC18 C6 or DtBu18 C6 diluted in alkylbenzenes with an added phase modifier such as decanol or especially isotridecanol

  13. Profiling of lipophilic and phenolic phytochemicals of four cultivars from cherimoya (Annona cherimola Mill.).

    Science.gov (United States)

    Santos, Sónia A O; Vilela, Carla; Camacho, João F; Cordeiro, Nereida; Gouveia, Manuela; Freire, Carmen S R; Silvestre, Armando J D

    2016-11-15

    The lipophilic and phenolic extractives of the ripe mesocarp of four cherimoya cultivars ('Perry Vidal', 'Mateus I', 'Mateus III' and 'Funchal') from Madeira Island, were studied for the first time. The predominant lipophilic compounds are kaurene diterpenes (42.2-59.6%), fatty acids (18.0-35.6%) and sterols (9.6-23.7%). Kaur-16-en-19-oic acid is the major lipophilic component of all cultivars accounting between 554 and 1350mgkg(-1) of dry material. The studied fruits also contain a high variety of flavan-3-ols, including galloylated and non-galloylated compounds. Five phenolic compounds were identified for the first time: catechin, (epi)catechin-(epi)gallocatechin, (epi)gallocatechin, (epi)afzelechin-(epi)catechin and procyanidin tetramer. 'Mateus I' and 'Mateus III' cultivars present the highest content of phenolic compounds (6299 and 9603mgkg(-1) of dry weight, respectively). These results support the use of this fruit as a rich source of health-promoting components, with the capacity to prevent or delay the progress of oxidative-stress related disorders. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Experimental investigation of the abrasive crown dynamics in orbital atherectomy.

    Science.gov (United States)

    Zheng, Yihao; Belmont, Barry; Shih, Albert J

    2016-07-01

    Orbital atherectomy is a catheter-based minimally invasive procedure to modify the plaque within atherosclerotic arteries using a diamond abrasive crown. This study was designed to investigate the crown motion and its corresponding contact force with the vessel. To this end, a transparent arterial tissue-mimicking phantom made of polyvinyl chloride was developed, a high-speed camera and image processing technique were utilized to visualize and quantitatively analyze the crown motion in the vessel phantom, and a piezoelectric dynamometer measured the forces on the phantom during the procedure. Observed under typical orbital atherectomy rotational speeds of 60,000, 90,000, and 120,000rpm in a 4.8mm caliber vessel phantom, the crown motion was a combination of high-frequency rotation at 1000, 1500, and 1660.4-1866.1Hz and low-frequency orbiting at 18, 38, and 40Hz, respectively. The measured forces were also composed of these high and low frequencies, matching well with the rotation of the eccentric crown and the associated orbital motion. The average peak force ranged from 0.1 to 0.4N at different rotational speeds. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Homeostasis in leaf water potentials on leeward and windward sides of desert shrub crowns: water loss control vs. high hydraulic efficiency.

    Science.gov (United States)

    Iogna, Patricia A; Bucci, Sandra J; Scholz, Fabián G; Goldstein, Guillermo

    2013-11-01

    Phenotypic plasticity in morphophysiological leaf traits in response to wind was studied in two dominant shrub species of the Patagonian steppe, used as model systems for understanding effects of high wind speed on leaf water relations and hydraulic properties of small woody plants. Morpho-anatomical traits, hydraulic conductance and conductivity and water relations in leaves of wind-exposed and protected crown sides were examined during the summer with nearly continuous high winds. Although exposed sides of the crowns were subjected to higher wind speeds and air saturation deficits than the protected sides, leaves throughout the crown had similar minimum leaf water potential (ΨL). The two species were able to maintain homeostasis in minimum ΨL using different physiological mechanisms. Berberis microphylla avoided a decrease in the minimum ΨL in the exposed side of the crown by reducing water loss by stomatal control, loss of cell turgor and low epidermal conductance. Colliguaja integerrima increased leaf water transport efficiency to maintain transpiration rates without increasing the driving force for water loss in the wind-exposed crown side. Leaf physiological changes within the crown help to prevent the decrease of minimum ΨL and thus contribute to the maintenance of homeostasis, assuring the hydraulic integrity of the plant under unfavorable conditions. The responses of leaf traits that contribute to mechanical resistance (leaf mass per area and thickness) differed from those of large physiological traits by exhibiting low phenotypic plasticity. The results of this study help us to understand the unique properties of shrubs which have different hydraulic architecture compared to trees.

  16. Extracting oil palm crown from WorldView-2 satellite image

    Science.gov (United States)

    Korom, A.; Phua, M.-H.; Hirata, Y.; Matsuura, T.

    2014-02-01

    Oil palm (OP) is the most commercial crop in Malaysia. Estimating the crowns is important for biomass estimation from high resolution satellite (HRS) image. This study examined extraction of individual OP crown from a WorldView-2 image using twofold algorithms, i.e., masking of Non-OP pixels and detection of individual OP crown based on the watershed segmentation of greyscale images. The study site was located in Beluran district, central Sabah, where matured OPs with the age ranging from 15 to 25 years old have been planted. We examined two compound vegetation indices of (NDVI+1)*DVI and NDII for masking non-OP crown areas. Using kappa statistics, an optimal threshold value was set with the highest accuracy at 90.6% for differentiating OP crown areas from Non-OP areas. After the watershed segmentation of OP crown areas with additional post-procedures, about 77% of individual OP crowns were successfully detected in comparison to the manual based delineation. Shape and location of each crown segment was then assessed based on a modified version of the goodness measures of Möller et al which was 0.3, indicating an acceptable CSGM (combined segmentation goodness measures) agreements between the automated and manually delineated crowns (perfect case is '1').

  17. Extracting oil palm crown from WorldView-2 satellite image

    International Nuclear Information System (INIS)

    Korom, A; Phua, M-H; Hirata, Y; Matsuura, T

    2014-01-01

    Oil palm (OP) is the most commercial crop in Malaysia. Estimating the crowns is important for biomass estimation from high resolution satellite (HRS) image. This study examined extraction of individual OP crown from a WorldView-2 image using twofold algorithms, i.e., masking of Non-OP pixels and detection of individual OP crown based on the watershed segmentation of greyscale images. The study site was located in Beluran district, central Sabah, where matured OPs with the age ranging from 15 to 25 years old have been planted. We examined two compound vegetation indices of (NDVI+1)*DVI and NDII for masking non-OP crown areas. Using kappa statistics, an optimal threshold value was set with the highest accuracy at 90.6% for differentiating OP crown areas from Non-OP areas. After the watershed segmentation of OP crown areas with additional post-procedures, about 77% of individual OP crowns were successfully detected in comparison to the manual based delineation. Shape and location of each crown segment was then assessed based on a modified version of the goodness measures of Möller et al which was 0.3, indicating an acceptable CSGM (combined segmentation goodness measures) agreements between the automated and manually delineated crowns (perfect case is '1')

  18. Lipophilic manganese porphyrin crosses blood-brain barrier

    International Nuclear Information System (INIS)

    Nelson, J.A.; Cegnar, J.; Spence, A.M.; Richards, T.L.; Golden, R.N.; Muzi, M.

    1987-01-01

    Most reports on manganese porphyrins as MR imaging contrast agents have focused on a water-soluble compound, Mn-TPPS4. Phototherapy researchers have noted that lipophilic components of hematoporphyrin derivative sensitize normal brain tissue to light-stimulated photodestruction. This observation suggests that a lipophilic paramagnetic agent might be useful for brain contrast enhancement. The current experiments were designed to test the MR imaging effects of a lipid-soluble compound, Mn-mesoporphyrin. An intravenous injection of 0.05 μmoles/kg was administered to rats with a well-characterized astrocytic glioma implanted into the right cerebral hemisphere. MR imaging experiments performed at 2 T on a General Electric CSI-II system revealed T1 relaxation shortening in both normal brain and tumor. Delayed images at 24 hours revealed persistent selective contrast agent enhancement at the gross tumor site

  19. Lipophilicity of basic drugs measured by hydrophilic interaction chromatography.

    Science.gov (United States)

    Bard, Bruno; Carrupt, Pierre-Alain; Martel, Sophie

    2009-05-28

    RPLC gains acceptance in pharmaceutical research for the rapid determination of lipophilicity but remains limited for the determination of partition coefficients of moderate to strong basic compounds under their neutral form because stationary phases are not compatible with high pH conditions. In this work, HILIC technique was used to accurately measure log P(oct) of the neutral form of basic drugs by measuring the difference between 2 isocratic log k values (Delta log k(0-95)) of their cationic form.

  20. Design and optimization of self-nanoemulsifying formulations for lipophilic drugs

    International Nuclear Information System (INIS)

    Zhao, Tianjing; Maniglio, Devid; Motta, Antonella; Migliaresi, Claudio; Chen, Jie; Chen, Bin

    2015-01-01

    The purpose of the current study was to develop and optimize novel self-nanoemulsifying drug delivery systems (SNEDDS) with a high proportion of essential oil as carriers for lipophilic drugs. Solubility and droplet size as a function of the composition were investigated, and a ternary phase diagram was constructed in order to identify the self-emulsification regions. The optimized SNEDDS formulation consisted of lemon essential oil (oil), Cremophor RH40 (surfactant) and Transcutol HP (co-surfactant) in the ratio 50:30:20 (v/v). Ibuprofen was chosen as the model drug. The droplet size, ζ-potential and stability of the drug-loaded optimized formulations were determined. The stability of SNEDDS was proved after triple freezing/thawing cycles and storage at 4 °C and 25 °C for 3 months. In vitro drug release studies of optimized SNEDDS revealed a significant increase of the drug release and release rate in comparison to the Ibuprofen suspension (80% versus approximately 40% in 2 h). The results indicated that these SNEDDS formulations could be used to improve the bioavailability of lipophilic drugs. (paper)

  1. Overdenture dengan Pegangan Telescopic Crown

    Directory of Open Access Journals (Sweden)

    Pambudi Santoso

    2014-06-01

    Full Text Available Kaitan presisi merupakan alat retensi mekanis yang menghubungkan antara satu atau lebih pegangan gigi tiruan, yang bertujuan untuk menambah retensi dan/atau stabilisasi. Kaitan presisi dapat digunakan secara luas pada gigi tiruan cekat, gigi tiruan sebagian lepasan, overdenture, implant untuk retensi overdenture, dan protesa maksilo fasial. Overdenture dengan kaitan presisi dapat membantu dalam pembagian beban kunyah, meminimalkan trauma pada gigi pegangan dan jaringan lunak, meminimalkan resorbsi tulang, dan meningkatkan estetik dan pengucapan suara. Salah satu jenis dari kaitan presisi adalah telescopic crown, terdiri dari 2 macam mahkota, yaitu mahkota primer yang melekat secara permanen pada gigi penyangga, dan mahkota sekunder yang melekat pada gigi tiruan. Tujuan pemaparan kasus ini adalah untuk memberikan informasi tentang rehabilitasi pasien edentulous sebagian rahang atas dengan telescopic crown..  Pasien wanita berusia 45 tahun datang ke klinik prostodonsia RSGM Prof.Soedomo dengan keluhan ingin dibuatkan gigi tiruan. Pasien kehilangan gigi 11 12 15 16 17 21 22 24 25 26 dan 27 yang diindikasikan untuk pembuatan overdenture gigi tiruan sebagian lepasan (GTS kerangka logam dengan pegangan telescopic crown pada gigi 13 dan 14 dengan sistem parallel-sided crown. Tahap-tahap pembuatan telescopic crown yaitu mencetak model study dengan catatan gigit pendahuluan. Perawatan saluran dilakukan pada akar gigi 13, dilanjutkan pemasangan pasak fiber serta rewalling dinding bukal. Gigi 13 dan 14 dilakukan preparasi mahkota penuh, dilanjutkan dengan pencetakan model kerja untuk coping primer dan kerangka logam dengan metode double impression. Coping primer disementasi pada gigi penyangga, dilanjutkan pasang coba coping sekunder beserta kerangka logam. Selanjutnya dilakukan pencatatan gigit, pencetakan model kerja, penyusunan gigi dan pasang coba penyusunan gigi pada pasien. Prosedur dilanjutkan dengan proses di laboratorium, serta insersi pada

  2. Are lipophilic beta-blockers preferable for peri-operative ...

    African Journals Online (AJOL)

    Adele

    management of hypertension and post myocardial infarction.4-6. Are lipophilic ... studies in hypertensive medical patients showed no difference in cardiovascular ... atenolol and bendroflumethiazide arm.7 In meta-analyses of beta-blocker ...

  3. An investigation of crown fuel bulk density effects on the dynamics of crown fire initiation in shrublands

    Science.gov (United States)

    Watcharapong Tachajapong; Jesse Lozano; Shankar Mahalingam; Xiangyang Zhou; David R. Weise

    2008-01-01

    Crown fire initiation is studied by using a simple experimental and detailed physical modeling based on Large Eddy Simulation (LES). Experiments conducted thus far reveal that crown fuel ignition via surface fire occurs when the crown base is within the continuous flame region and does not occur when the crown base is located in the hot plume gas region of the surface...

  4. Innovative polymeric system (IPS) for solvent-free lipophilic drug transdermal delivery via dissolving microneedles.

    Science.gov (United States)

    Dangol, Manita; Yang, Huisuk; Li, Cheng Guo; Lahiji, Shayan Fakhraei; Kim, Suyong; Ma, Yonghao; Jung, Hyungil

    2016-02-10

    Lipophilic drugs are potential drug candidates during drug development. However, due to the need for hazardous organic solvents for their solubilization, these drugs often fail to reach the pharmaceutical market, and in doing so highlight the importance of solvent free systems. Although transdermal drug delivery systems (TDDSs) are considered prospective safe drug delivery routes, a system involving lipophilic drugs in solvent free or powder form has not yet been described. Here, we report, for the first time, a novel approach for the delivery of every kind of lipophilic drug in powder form based on an innovative polymeric system (IPS). The phase transition of powder form of lipophilic drugs due to interior chemical bonds between drugs and biodegradable polymers and formation of nano-sized colloidal structures allowed the fabrication of dissolving microneedles (DMNs) to generate a powerful TDDS. We showed that IPS based DMN with powder capsaicin enhances the therapeutic effect for treatment of the rheumatic arthritis in a DBA/1 mouse model compared to a solvent-based system, indicating the promising potential of this new solvent-free platform for lipophilic drug delivery. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. [Comparison of the clinical effects of selective laser melting deposition basal crowns and cobalt chromium alloy base crowns].

    Science.gov (United States)

    Li, Jing-min; Wang, Wei-qian; Ma, Jing-yuan

    2014-06-01

    To evaluate the clinical effects of selective laser melting (SLM) deposition basal crowns and cobalt chromium alloy casting base crowns. One hundred and sixty eight patients treated with either SLM deposition basal crowns (110 teeth) or cobalt chromium alloy casting basal crowns (110 teeth) were followed-up for 1 month, 6 months, 12 months and 24 months. The revised standard of American Public Health Association was used to evaluate the clinical effect of restoration, including the color of porcelain crowns, gingival inflammation, gingival margin discoloration, and crack or fracture. Data analysis was conducted with SPSS 20 software package for Student's t test and Chi-square test. Six cases were lost to follow-up. The patients who were treated with SLM deposition basal crowns (104 teeth) and cobalt chromium alloy casting base crowns (101 teeth) completed the study. Patients were more satisfied with SLM deposition cobalt chromium alloy porcelain crowns. There was 1 prosthesis with poor marginal fit after 24 months of restoration in SLM crowns. There were 6 prostheses with edge coloring and 8 with poor marginal fit in cobalt chromium alloy casting base crowns, which was significantly different between the 2 groups(P<0.05). The SLM deposition copings results in smaller edge coloring and better marginal fit than those of cobalt-chrome copings. Patients are pleased with short-term clinical results.

  6. Agricultural Crown Land in Saskatchewan

    International Nuclear Information System (INIS)

    Pyle, W.E.

    1998-01-01

    The petroleum industry's interest in provincial crown land in the agricultural area of Saskatchewan has grown over the last two decades. Agricultural land is regulated by the Saskatchewan Department of Agriculture and Food, Lands Branch. Since 1974 surface lease contracts by oil and gas companies have increased from 1,400 to the present 3,700. Resource lands are regulated by Saskatchewan Environment and Resource Management. There are 8.8 million acres of crown agricultural land in Saskatchewan, most of which is held without title. Crown land management is meant to provide a long term management approach to crown lands that balances economic, environmental and social benefits for present and future generations. The oil and gas industry is an important participant in crown land management. Revenues from petroleum and gas surface leasing, and seismic licensing totals more than five million dollars annually. In 1995/96, there were 54 companies establishing new oil and gas leases on crown land in Saskatchewan. This paper provides details of current policies which apply to petroleum and gas leasing and seismic exploration, and environmental guidelines for companies developing well sites, compressor and metering stations, access roads and easements. 3 tabs

  7. Crown rust control on oats

    International Nuclear Information System (INIS)

    Frey, K.J.; Browning, J.A.; Simons, M.D.

    1976-01-01

    Attempts have been made to test the relative effectiveness of EMS treatment for inducing tolerance to crown rust among oat strains Clintland-60 of different ploidy levels. One strain of diploid and one of tetraploid oats were treated with EMS. These two strains are as susceptible to damage from crown rust as are cultivars of hexaploid oats. Multiline cultivars of oats have been shown to provide adequate protection from economic loss due to crown-rust disease in Iowa. Since 1968, eleven multiline cultivars of oats have been released from the Iowa station for use in commercial production in the midwestern USA. During the past two winter seasons, the effectiveness of multiline oat cultivars against crown-rust disease has been researched in Texas, USA, which has a ''long rust season'' of about four months, not an Iowa ''short rust season''. The protection against crown rust afforded by the multiline cultivars appeared equally good in Texas and Iowa. The seasonal productions of crown-rust spores relative to completely resistant and susceptible checks were nearly identical in both environments. Fifteen new isolines of oats have been developed for use in multiline varieties, with seed supplies sufficiently large for immediate use

  8. Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown.

    Science.gov (United States)

    Ji, Min-Kyung; Park, Ji-Hee; Park, Sang-Won; Yun, Kwi-Dug; Oh, Gye-Jeong; Lim, Hyun-Pil

    2015-08-01

    This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau®Zirconia and ZENOSTAR®ZR translucent) and lithium disilicate glass ceramic (IPS e.max®press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max®press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) (Pmarginal discrepancy (Pmarginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR®ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau®Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max®press) had overextended margins.

  9. Clinical performance - a reflection of damage accumulation in ceramic dental crowns

    Energy Technology Data Exchange (ETDEWEB)

    Rekow, D.E. [Univ. of Medicine and Dentistry of New Jersey, Newark, NJ (United States). Dept. of Orthodontics; Thompson, V.P. [Univ. of Medicine and Dentistry of New Jersey, Newark, NJ (United States). New Jersey Dental School

    2001-07-01

    All-ceramic dental crowns have tremendous appeal for patients - their esthetics nearly match those of natural teeth. Unfortunately, the most esthetic materials are brittle and, consequently, are vulnerable to damage relating to shaping which is exacerbated during cyclic loading during normal chewing. Clinical performance of all-ceramic dental prostheses are directly dependent on damage introduced during fabrication and during fatigue loading associated with function. The accumulation of damage results in unacceptably high failure rates (where failure is defined as a complete fracture requiring replacement of the prosthesis). The relation between shaping damage and fatigue damage on clinical performance of all-ceramic dental crowns was investigated. Materials used commercially for all-ceramic crowns and investigated in this study included a series of different microstructures of machinable glass ceramics (Corning), aluminas and porcelains (Vita Zahnfabrik), and zirconia (Norton). As monolithic materials, strong, tough, fatigue-resistant materials are not sufficiently esthetic for crowns. Crowns fabricated from monolithic esthetic materials have high failure rates. Layering ceramics could provide acceptable strength through management of damage accumulation. (orig.)

  10. [Computer aided design and manufacture of the porcelain fused to metal crown].

    Science.gov (United States)

    Nie, Xin; Cheng, Xiaosheng; Dai, Ning; Yu, Qing; Hao, Guodong; Sun, Quanping

    2009-04-01

    In order to satisfy the current demand for fast and high-quality prosthodontics, we have carried out a research in the fabrication process of the porcelain fused to metal crown on molar with CAD/CAM technology. Firstly, we get the data of the surface mesh on preparation teeth through a 3D-optical grating measuring system. Then, we reconstruct the 3D-model crown with the computer-aided design software which was developed by ourselves. Finally, with the 3D-model data, we produce a metallic crown on a high-speed CNC carving machine. The result has proved that the metallic crown can match the preparation teeth ideally. The fabrication process is reliable and efficient, and the restoration is precise and steady in quality.

  11. Selective crystallization of cations with crown ethers

    International Nuclear Information System (INIS)

    Heffels, Dennis Egidius

    2014-01-01

    The aim of this work was to study the selectivity and preferences of the incorporation of differently sized cations in the cavities of various crown ethers and the characterization of the resulting compounds. The coordination preferences of crown ethers with different cavities have long been known, and the impact of other effects on the structure formation have increasingly become the focus of attention. In this work a comparative overview of the coordination preferences depending on various factors was undertaken. The focus was mainly on the variation of the cavity of the crown ether in the presence of differently sized cations. In addition, the effects of the solvent and differently coordinating anions have been investigated. Within the framework of this work, basic coordination preferences could be detected with rare earth nitrates, which are affected particularly by the choice of the solvent. The formation of different types of structures could be controlled by varying the conditions such that the incorporation of the cation in the cavity of the crown ether was influenced and the formation of a particular type of structure can be influenced partly by the choice of solvent. In this case no direct preferences for the incorporation into the cavity of the crown ether in relation to the cation size were observed for rare earth cations. However, the coordination of the crown ether leads in each case - for lanthanides - to rather high coordination numbers. A total of five new rare earth complexes and two structural variants could be observed with crown ethers. In the study of the selectivity of the incorporation into the cavity, known structures were also reproduced and further structures were characterized but the crystal structures not entirely solved. With the use of monovalent cations such as potassium, lithium or silver a total of nine new compounds could be synthesized, while no clear preferences for the incorporation of certain cations were detected. The

  12. Urban Crowns: crown analysis software to assist in quantifying urban tree benefits

    Science.gov (United States)

    Matthew F. Winn; Sang-Mook Lee Bradley; Philip A. Araman

    2010-01-01

    UrbanCrowns is a Microsoft® Windows®-based computer program developed by the U.S. Forest Service Southern Research Station. The software assists urban forestry professionals, arborists, and community volunteers in assessing and monitoring the crown characteristics of urban trees (both deciduous and coniferous) using a single side-view digital photograph. Program output...

  13. Influence of cement film thickness on the retention of implant-retained crowns.

    Science.gov (United States)

    Mehl, Christian; Harder, Sönke; Steiner, Martin; Vollrath, Oliver; Kern, Matthias

    2013-12-01

    The main goal of this study was to establish a new, high precision procedure to evaluate the influence of cement film thickness on the retention of cemented implant-retained crowns. Ninety-six tapered titanium abutments (6° taper, 4.3 mm diameter, Camlog) were shortened to 4 mm. Computer-aided design was used to design the crowns, and selective laser sintering, using a cobalt-chromium alloy, was used to produce the crowns. This method used a focused high-energy laser beam to fuse a localized region of metal powder to build up the crowns gradually. Before cementing, preset cement film thicknesses of 15, 50, 80, or 110 μm were established. Glass ionomer, polycarboxylate, or resin cements were used for cementation. After 3 days storage in demineralized water, the retention of the crowns was measured in tension using a universal testing machine. The cement film thicknesses could be achieved with a high level of precision. Interactions between the factors cement and cement film thickness could be found (p ≤ 0.001). For all cements, crown retention decreased significantly between a cement film thickness of 15 and 50 μm (p ≤ 0.001). At 15 μm cement film thickness, the resin cement was the most retentive cement, followed by the polycarboxylate and then the glass ionomer cement (p ≤ 0.05). The results suggest that cement film thickness has an influence on the retentive strength of cemented implant-retained crowns. © 2013 by the American College of Prosthodontists.

  14. A novel approach to internal crown characterization for coniferous tree species classification

    Science.gov (United States)

    Harikumar, A.; Bovolo, F.; Bruzzone, L.

    2016-10-01

    The knowledge about individual trees in forest is highly beneficial in forest management. High density small foot- print multi-return airborne Light Detection and Ranging (LiDAR) data can provide a very accurate information about the structural properties of individual trees in forests. Every tree species has a unique set of crown structural characteristics that can be used for tree species classification. In this paper, we use both the internal and external crown structural information of a conifer tree crown, derived from a high density small foot-print multi-return LiDAR data acquisition for species classification. Considering the fact that branches are the major building blocks of a conifer tree crown, we obtain the internal crown structural information using a branch level analysis. The structure of each conifer branch is represented using clusters in the LiDAR point cloud. We propose the joint use of the k-means clustering and geometric shape fitting, on the LiDAR data projected onto a novel 3-dimensional space, to identify branch clusters. After mapping the identified clusters back to the original space, six internal geometric features are estimated using a branch-level analysis. The external crown characteristics are modeled by using six least correlated features based on cone fitting and convex hull. Species classification is performed using a sparse Support Vector Machines (sparse SVM) classifier.

  15. Estimating average tree crown size using high-resolution airborne data

    Czech Academy of Sciences Publication Activity Database

    Brovkina, Olga; Latypov, I.; Cienciala, E.

    2015-01-01

    Roč. 9, may 13 (2015), 096053-1-096053-13 ISSN 1931-3195 R&D Projects: GA MŠk(CZ) LO1415; GA MŠk OC09001 Institutional support: RVO:67179843 Keywords : crown size * airborne data * spruce * granulometry Subject RIV: GK - Forestry Impact factor: 0.937, year: 2015

  16. Utilizing food effects to overcome challenges in delivery of lipophilic bioactives: structural design of medical and functional foods.

    Science.gov (United States)

    McClements, David Julian

    2013-12-01

    The oral bioavailability of many lipophilic bioactives, such as pharmaceuticals and nutraceuticals, is relatively low due to their poor solubility, permeability and/or chemical stability within the human gastrointestinal tract (GIT). The oral bioavailability of lipophilic bioactives can be improved by designing food matrices that control their release, solubilization, transport and absorption within the GIT. This article discusses the challenges associated with delivering lipophilic bioactive components, the impact of food composition and structure on oral bioavailability and the design of functional and medical foods for improving the oral bioavailability of lipophilic bioactives. Food-based delivery systems can be used to improve the oral bioavailability of lipophilic bioactives. There are a number of potential advantages to delivering lipophilic bioactives using functional or medical foods: greater compliance than conventional delivery forms; increased bioavailability and efficacy; and reduced variability in biological effects. However, food matrices are structurally complex multicomponent materials and research is still needed to identify optimum structures and compositions for particular bioactives.

  17. Lung surfactant microbubbles increase lipophilic drug payload for ultrasound-targeted delivery.

    Science.gov (United States)

    Sirsi, Shashank R; Fung, Chinpong; Garg, Sumit; Tianning, Mary Y; Mountford, Paul A; Borden, Mark A

    2013-01-01

    The cavitation response of circulating microbubbles to targeted ultrasound can be used for noninvasive, site-specific delivery of shell-loaded materials. One challenge for microbubble-mediated delivery of lipophilic compounds is the limitation of drug loading into the microbubble shell, which is commonly a single phospholipid monolayer. In this study, we investigated the use of natural lung surfactant extract (Survanta(®), Abbott Nutrition) as a microbubble shell material in order to improve drug payload and delivery. Pulmonary surfactant extracts such as Survanta contain hydrophobic surfactant proteins (SP-B and SP-C) that facilitate lipid folding and retention on lipid monolayers. Here, we show that Survanta-based microbubbles exhibit wrinkles in bright-field microscopy and increased lipid retention on the microbubble surface in the form of surface-associated aggregates observed with fluorescence microscopy. The payload of a model lipophilic drug (DiO), measured by flow cytometry, increased by over 2-fold compared to lipid-coated microbubbles lacking SP-B and SP-C. Lung surfactant microbubbles were highly echogenic to contrast enhanced ultrasound imaging at low acoustic intensities. At higher ultrasound intensity, excess lipid was observed to be acoustically cleaved for localized release. To demonstrate targeting, a biotinylated lipopolymer was incorporated into the shell, and the microbubbles were subjected to a sequence of radiation force and fragmentation pulses as they passed through an avidinated hollow fiber. Lung surfactant microbubbles showed a 3-fold increase in targeted deposition of the model fluorescent drug compared to lipid-only microbubbles. Our results demonstrate that lung surfactant microbubbles maintain the acoustic responsiveness of lipid-coated microbubbles with the added benefit of increased lipophilic drug payload.

  18. PEEK Primary Crowns with Cobalt-Chromium, Zirconia and Galvanic Secondary Crowns with Different Tapers—A Comparison of Retention Forces

    Directory of Open Access Journals (Sweden)

    Veronika Stock

    2016-03-01

    Full Text Available In prosthetic dentistry, double crown systems have proved their suitability as retainers for removable partial dentures. However, investigations in this context, regarding polyetheretherketone, are scarce. Therefore, the aim of this study was to test the retention force (RF between polyetheretherketone (PEEK primary and cobalt-chromium (CoCr, zirconia (ZrO2 and galvanic (GAL secondary crowns with three different tapers. Primary PEEK-crowns were milled with the tapers 0°, 1°, and 2° (n = 10/taper, respectively. Afterwards, 90 secondary crowns were fabricated: (i 30 CoCr-crowns milled from Ceramill Sintron (AmannGirrbach, Koblach, Austria (n = 10/taper, (ii 30 ZrO2-crowns milled from Ceramill ZI (AmannGirrbach, Koblach, Austria (n = 10/taper, and (iii 30 GAL-crowns made using electroforming (n = 10/taper. RF was measured in a pull-off test (20 pull-offs/specimen and data were analyzed using 2-/1-way Analysis of Variance (ANOVA followed by the Tukey-Honestly Significant Difference (HSD post hoc test and linear regression analyses (p < 0.05. The measured mean RF values ranged between 9.6 and 38.2 N. With regard to the 0°, 1°, and 2° tapered crowns, no statistically significant differences between CoCr and ZrO2 were observed (p > 0.141. At 0° taper, no differences in retention forces between GAL, CrCr, and ZrO2 crowns were found (p = 0.075. However, at 1° and 2° taper, lower RF for GAL-crowns were observed (p < 0.009, p < 0.001, respectively. According to this laboratory study, PEEK might be a suitable material for primary crowns, regardless of the taper and the material of secondary crown. Long-term results, however, are still necessary.

  19. All-ceramic crowns: bonding or cementing?

    Science.gov (United States)

    Pospiech, Peter

    2002-12-01

    Despite the wide variety of all-ceramic systems available today, the majority of dental practitioners hesitate to recommend and insert all-ceramic crowns. This article regards the nature of the ceramic materials, the principles of bonding and adhesion, and the clinical problems of the acid-etch technique for crowns. Advantages and disadvantages are discussed, and the influences of different factors on the strength of all-ceramic crowns are presented. Finally, the conclusion is drawn that conventional cementing of all-ceramic crowns is possible when the specific properties of the ceramics are taken into consideration.

  20. Stress distribution difference between Lava Ultimate full crowns and IPS e.max CAD full crowns on a natural tooth and on tooth-shaped implant abutments.

    Science.gov (United States)

    Krejci, Ivo; Daher, René

    2017-04-01

    The goal of this short communication is to present finite element analysis comparison of the stress distribution between CAD/CAM full crowns made of Lava Ultimate and of IPS e.max CAD, adhesively luted to natural teeth and to implant abutments with the shape of natural teeth. Six 3D models were prepared using a 3D content-creating software, based on a micro-CT scan of a human mandibular molar. The geometry of the full crown and of the abutment was the same for all models representing Lava Ultimate full crowns (L) and IPS e.max CAD full crowns (E) on three different abutments: prepared natural tooth (n), titanium abutment (t) and zirconia abutment (z). A static load of 400 N was applied on the vestibular and lingual cusps, and fixtures were applied to the base of the models. After running the static linear analysis, the post-processing data we analyzed. The stress values at the interface between the crown and the abutment of the Lt and Lz groups were significantly higher than the stress values at the same interface of all the other models. The high stress concentration in the adhesive at the interface between the crown and the abutment of the Lava Ultimate group on implants might be one of the factors contributing to the reported debondings of crowns.

  1. Physicochemical Properties and Lipophilicity of Polydatin-Lecithin ...

    African Journals Online (AJOL)

    Yang Liu, Baogang Wang, Qian Zhang, Kunfeng Liu, Quanxi Wu ... HPLC analysis found that the solubility of polydatin in n-octanol at 25 °C was enhanced from 0.41 mg/mL to 21.98 mg/mL by complexing with lecithin, indicating that the lipophilicity of polydatin was significantly improved. Conclusion: Polydatin and lecithin in ...

  2. Digital photo monitoring for tree crown

    Science.gov (United States)

    Neil Clark; Sang-Mook Lee

    2007-01-01

    Assessing change in the amount of foliage within a tree’s crown is the goal of crown transparency estimation, a component in many forest health assessment programs. Many sources of variability limit analysis and interpretation of crown condition data. Increased precision is needed to detect more subtle changes that are important for detection of health problems....

  3. Dentin-bonded all-ceramic crowns: current status.

    Science.gov (United States)

    Burke, F J; Qualtrough, A J; Hale, R W

    1998-04-01

    Dentin-bonded all-ceramic crowns employ contemporary techniques to lute the crown to the tooth using a resin luting material and dentin-bonding system. The advantages of these crowns are that they provide good esthetics and fracture resistance and can be used in cases of substantial tooth loss. Their principal disadvantages are that the luting procedure is more time-consuming and that these crowns should not be used where margins are subgingival. Dentin-bonded all-ceramic crowns may be a useful addition to the dentist's armamentarium, but long-term clinical studies are needed to fully assess their performance.

  4. Pericoronal radiolucency associated with incomplete crown

    Energy Technology Data Exchange (ETDEWEB)

    Nah, Kyung Soo [Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Yangsan (Korea, Republic of)

    2013-12-15

    The author experienced 8 cases of pericoronal radiolucency involving an incomplete tooth crown that had not developed to form the cemento-enamel junction, and the underdeveloped crown sometimes appeared to be floating within the radiolucency radiographically. The first impression was that these cystic lesions had odontogenic keratocysts, but half of them turned out to be dentigerous cysts histopathologically. There has been no report concerning odontogenic cysts involving an incompletely developed crown. The purpose of this paper is to report that dentigerous cysts may develop before the completion of the cemento-enamel junction of a developing crown.

  5. Pericoronal radiolucency associated with incomplete crown

    International Nuclear Information System (INIS)

    Nah, Kyung Soo

    2013-01-01

    The author experienced 8 cases of pericoronal radiolucency involving an incomplete tooth crown that had not developed to form the cemento-enamel junction, and the underdeveloped crown sometimes appeared to be floating within the radiolucency radiographically. The first impression was that these cystic lesions had odontogenic keratocysts, but half of them turned out to be dentigerous cysts histopathologically. There has been no report concerning odontogenic cysts involving an incompletely developed crown. The purpose of this paper is to report that dentigerous cysts may develop before the completion of the cemento-enamel junction of a developing crown.

  6. Extraction separation of lithium isotopes with crown-ethers

    International Nuclear Information System (INIS)

    Tsivadze, A.Yu.; Demin, S.V.; Levkin, A.V.; Zhilov, V.I.; Nikol'skij, S.F.; Knyazev, D.A.

    1990-01-01

    By the method of extraction chromatography lithium isotope separation coefficients are measured during chemical isotope exchange between lithium aquocomplex and its complex in chloroform with crown-ethers: benzo-15-crown-5, 15crown-5, dicyclohexano-18-crown-6 and dibenzo-18-crown-6. Lithium perchlorate and trichloroacetate are the salts extracted. Values of 6 Li/ 7 Li isotope separation are 1.0032-1.020

  7. Activity-guided identification of acetogenins as novel lipophilic antioxidants present in avocado pulp (Persea americana).

    Science.gov (United States)

    Rodríguez-Sánchez, Dariana; Silva-Platas, Christian; Rojo, Rocío P; García, Noemí; Cisneros-Zevallos, Luis; García-Rivas, Gerardo; Hernández-Brenes, Carmen

    2013-12-30

    Avocado fruit is a rich source of health-related lipophilic phytochemicals such as monounsaturated fatty acids, tocopherols, carotenes, acetogenins and sterols. However, limited information is available on the contribution of specific phytochemicals to the overall antioxidant capacity (AOC) of the fruit. Centrifugal partition chromatography was used as fractionation tool, guided by an in vitro chemical assay of oxygen radical absorbance capacity (ORAC). Subsequent experiments focused on isolation and characterization of the chemical nature of the main contributors to lipophilic AOC of avocado pulp. ORAC values obtained for acetogenins were contrasted with results from an isolated kidney mitochondria membrane lipid peroxidation bioassay. The present study established that lipophilic AOC of the pulp was significantly higher than its hydrophilic AOC. Our results confirmed the presence of acetogenins in the fractions with highest lipophilic AOC, and for the first time linked them as contributors to lipophilic-ORAC values. Further HPLC-PDA/MS-TOF analysis led to structural elucidation of two novel acetogenins, not previously reported as present in avocado pulp, along with five already known related-compounds. Antioxidant properties observed for avocado pulp acetogenins by the ORAC assay suggested that, in the presence of an emulsifying agent, acetogenins could serve as novel lipophilic antioxidants in a food matrix. Results from isolated mitochondria lipid peroxidation bioassay, indicated that L-ORAC values which may have relevance for food matrix applications, should not be interpreted to have a direct relevance in health-related claims, compounds need to be evaluated considering the complexity of biological systems. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Minor lipophilic compounds in edible insects

    OpenAIRE

    Monika Sabolová; Anna Adámková; Lenka Kouřimská; Diana Chrpová; Jan Pánek

    2016-01-01

    Contemporary society is faced with the question how to ensure suffiecient nutrition (quantity and quality) for rapidly growing population. One solution can be consumption of edible insect, which can have very good nutritional value (dietary energy, protein, fatty acids, fibers, dietary minerals and vitamins composition). Some edible insects species, which contains a relatively large amount of fat, can have a potential to be a „good" (interesting, new) source of minor lipophilic compound...

  9. Are lipophilic beta-blockers preferable for peri-operative ...

    African Journals Online (AJOL)

    There is therefore doubt whether atenolol is the correct cardioprotective drug in the surgical setting. It is possible that some of the physiochemical properties of atenolol (hydrophilic and cardioselective) may decrease it's efficacy in comparison to its more lipophilic congeners (such as propranolol, metoprolol, bisoprolol and ...

  10. Extraction efficiency of hydrophilic and lipophilic antioxidants from lyophilized foods using pressurized liquid extraction and manual extraction.

    Science.gov (United States)

    Watanabe, Jun; Oki, Tomoyuki; Takebayashi, Jun; Takano-Ishikawa, Yuko

    2014-09-01

    The efficient extraction of antioxidants from food samples is necessary in order to accurately measure their antioxidant capacities. α-Tocopherol and gallic acid were spiked into samples of 5 lyophilized and pulverized vegetables and fruits (onion, cabbage, Satsuma mandarin orange, pumpkin, and spinach). The lipophilic and hydrophilic antioxidants in the samples were sequentially extracted with a mixed solvent of n-hexane and dichloromethane, and then with acetic acid-acidified aqueous methanol. Duplicate samples were extracted: one set was extracted using an automated pressurized liquid extraction apparatus, and the other set was extracted manually. Spiked α-tocopherol and gallic acid were recovered almost quantitatively in the extracted lipophilic and hydrophilic fractions, respectively, especially when pressurized liquid extraction was used. The expected increase in lipophilic oxygen radical absorbance capacity (L-ORAC) due to spiking with α-tocopherol, and the expected increase in 2,2-diphenyl-1-picrylhydrazyl radical scavenging activities and total polyphenol content due to spiking with gallic acid, were all recovered in high yield. Relatively low recoveries, as reflected in the hydrophilic ORAC (H-ORAC) value, were obtained following spiking with gallic acid, suggesting an interaction between gallic acid and endogenous antioxidants. The H-ORAC values of gallic acid-spiked samples were almost the same as those of postadded (spiked) samples. These results clearly indicate that lipophilic and hydrophilic antioxidants are effectively extracted from lyophilized food, especially when pressurized liquid extraction is used. © 2014 Institute of Food Technologists®

  11. [Finite element analysis of the maxillary central incisor with crown lengthening surgery and post-core restoration in management of crown-root fracture].

    Science.gov (United States)

    Zhen, Min; Hu, Wen-jie; Rong, Qi-guo

    2015-12-18

    To construct the finite element models of maxillary central incisor and the simulations with crown lengthening surgery and post-core restoration in management of different crown-root fracture types, to investigate the stress intensity and distributions of these models mentioned above, and to analyze the indications of crown lengthening from the point of view of mechanics. An extracted maxillary central incisor and alveolar bone plaster model were scanned by Micro-CT and dental impression scanner (3shape D700) respectively. Then the 3D finite element models of the maxillary central incisor and 9 simulations with crown lengthening surgery and post-core restoration were constructed by Mimics 10.0, Geomagic studio 9.0 and ANSYS 14.0 software. The oblique static force (100 N) was applied to the palatal surface (the junctional area of the incisal 1/3 and middle 1/3), at 45 degrees to the longitudinal axis, then the von Mises stress of dentin, periodontal ligament, alveolar bone, post and core, as well as the periodontal ligament area, were calculated. A total of 10 high-precision three-dimensional finite element models of maxillary central incisor were established. The von Mises stress of models: post>dentin>alveolar bone>core>periodontal ligament, and the von Mises stress increased linearly with the augmentation of fracture degree (besides the core). The periodontal ligament area of the crown lengthening was reduced by 12% to 33%. The von Mises stress of periodontal ligament of the B2L2c, B2L3c, B3L1c, B3L2c, B3L3c models exceeded their threshold limit value, respectively. The maxillary central incisors with the labial fracture greater than three-quarter crown length and the palatal fracture deeper than 1 mm below the alveolar crest are not the ideal indications of the crown lengthening surgery.

  12. Food matrix and processing influence on carotenoid bioaccessibility and lipophilic antioxidant activity of fruit juice-based beverages.

    Science.gov (United States)

    Rodríguez-Roque, María Janeth; de Ancos, Begoña; Sánchez-Vega, Rogelio; Sánchez-Moreno, Concepción; Cano, M Pilar; Elez-Martínez, Pedro; Martín-Belloso, Olga

    2016-01-01

    The biological activity of carotenoids depends on their bioaccessibility and solubilization in the gastrointestinal tract. These compounds are poorly dispersed in the aqueous media of the digestive tract due to their lipophilic nature. Thus, it is important to analyze the extent to which some factors, such as the food matrix and food processing, may improve their bioaccessibility. Beverages formulated with a blend of fruit juices and water (WB), milk (MB) or soymilk (SB) were treated by high-intensity pulsed electric fields (HIPEF) (35 kV cm(-1) with 4 μs bipolar pulses at 200 Hz for 1800 μs), high-pressure processing (HPP) (400 MPa at 40 °C for 5 min) or thermal treatment (TT) (90 °C for 1 min) in order to evaluate the influence of food matrix and processing on the bioaccessibility of carotenoids and on the lipophilic antioxidant activity (LAA). The bioaccessibility of these compounds diminished after applying any treatment (HIPEF, HPP and TT), with the exception of cis-violaxanthin + neoxanthin, which increased by 79% in HIPEF and HPP beverages. The lowest carotenoid bioaccessibility was always obtained in TT beverages (losses up to 63%). MB was the best food matrix for improving the bioaccessibility of carotenoids, as well as the LAA. The results demonstrate that treatment and food matrix modulated the bioaccessibility of carotenoids as well as the lipophilic antioxidant potential of beverages. Additionally, HIPEF and HPP could be considered as promising technologies to obtain highly nutritional and functional beverages.

  13. High-Resolution Airborne UAV Imagery to Assess Olive Tree Crown Parameters Using 3D Photo Reconstruction: Application in Breeding Trials

    Directory of Open Access Journals (Sweden)

    Ramón A. Díaz-Varela

    2015-04-01

    Full Text Available The development of reliable methods for the estimation of crown architecture parameters is a key issue for the quantitative evaluation of tree crop adaptation to environment conditions and/or growing system. In the present work, we developed and tested the performance of a method based on low-cost unmanned aerial vehicle (UAV imagery for the estimation of olive crown parameters (tree height and crown diameter in the framework of olive tree breeding programs, both on discontinuous and continuous canopy cropping systems. The workflow involved the image acquisition with consumer-grade cameras on board a UAV and orthomosaic and digital surface model generation using structure-from-motion image reconstruction (without ground point information. Finally, geographical information system analyses and object-based classification were used for the calculation of tree parameters. Results showed a high agreement between remote sensing estimation and field measurements of crown parameters. This was observed both at the individual tree/hedgerow level (relative RMSE from 6% to 20%, depending on the particular case and also when average values for different genotypes were considered for phenotyping purposes (relative RMSE from 3% to 16%, pointing out the interest and applicability of these data and techniques in the selection scheme of breeding programs.

  14. Preformed crowns for decayed primary molar teeth.

    Science.gov (United States)

    Innes, Nicola P T; Ricketts, David; Chong, Lee Yee; Keightley, Alexander J; Lamont, Thomas; Santamaria, Ruth M

    2015-12-31

    Crowns for primary molars are preformed and come in a variety of sizes and materials to be placed over decayed or developmentally defective teeth. They can be made completely of stainless steel (know as 'preformed metal crowns' or PMCs), or to give better aesthetics, may be made of stainless steel with a white veneer cover or made wholly of a white ceramic material. In most cases, teeth are trimmed for the crowns to be fitted conventionally using a local anaesthetic. However, in the case of the Hall Technique, PMCs are pushed over the tooth with no local anaesthetic, carious tissue removal or tooth preparation. Crowns are recommended for restoring primary molar teeth that have had a pulp treatment, are very decayed or are badly broken down. However, few dental practitioners use them in clinical practice. This review updates the original review published in 2007. Primary objectiveTo evaluate the clinical effectiveness and safety of all types of preformed crowns for restoring primary teeth compared with conventional filling materials (such as amalgam, composite, glass ionomer, resin modified glass ionomer and compomers), other types of crowns or methods of crown placement, non-restorative caries treatment or no treatment. Secondary objectiveTo explore whether the extent of decay has an effect on the clinical outcome of primary teeth restored with all types of preformed crowns compared with those restored with conventional filling materials. We searched the following electronic databases: Cochrane Oral Health Group Trials Register (to 21 January 2015), Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library, 2014, Issue 12), MEDLINE via Ovid (1946 to 21 January 2015) and EMBASE via Ovid (1980 to 21 January 2015). We searched the US National Institutes of Health Trials Register (http://clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform for ongoing trials and Open Grey for grey literature (to

  15. COMPARSION EFFECTIVENES METHODS REPEIR CROWN TEETH IN DOGS

    OpenAIRE

    CHOOHNO V.S.

    2008-01-01

    Methods of dogs’ crown teeth restoration with using of anchor pin with light curable composite, glass fiber pin with light curable composite, stump crown with prosthetic crown were approved. Their effectiveness was compared. Greater reliability was shown by methods of stump crown with prosthetic crown, when using of which there was no that restoration damage in all cases, but there was no cosmetics effect. Restoration methods with using anchor pin with light curable composite and glass fiber ...

  16. Activity relationships for aromatic crown ethers

    International Nuclear Information System (INIS)

    Wilson, Mark James

    1998-01-01

    This thesis involves an investigation of aromatic crown ethers and a study of their binding constants for alkali metals. The study was motivated by the current needs of the semiconductor industry to improve the scavenging of mobile ions from fabricated circuits. A number of aromatic crown ethers have been sulphonated in an attempt to improve their water solubility and cation binding activity. These materials have been extensively studied and their binding activity determined. In collaboration with a molecular modelling study, the effect of ionisable sulphonate groups on the macrocycles' behaviour has been investigated. The broader issue of the effect of substituents in aromatic crown ethers has also been studied with the preparation of a wide range of substituted crown ethers. The cation binding activity of these materials has been found to bear a simple relationship to the electron withdrawing nature of the aromatic substituents. This relationship can be accurately monitored using electronic charge densities from molecular modelling and this rational has been applied to the study of proton ionisable and lariating crown ethers. The incorporation of crown ethers into polyamic acid and polyimide frameworks has also been investigated, where the resulting materials have been found to exhibit unusual cation binding and uptake properties. These results imply that the combination of the crown ethers' macrocycle and adjacent carboxylic acid residues, from the polyamic acids, are conducive to effective cationic binding. NMR measurements, in conjunction with molecular modelling, have been used to explore the geometry changes encountered as the crown ether goes from it's uncomplexed to its complexed state. The energy requirement for these geometry changes has subsequently been used to examine the cation selectivity of these materials. The electronic charge changes associated with the complexation have also been investigated and correlated with the theoretical results. (author)

  17. DNA methylation mediated control of gene expression is critical for development of crown gall tumors.

    Directory of Open Access Journals (Sweden)

    Jochen Gohlke

    Full Text Available Crown gall tumors develop after integration of the T-DNA of virulent Agrobacterium tumefaciens strains into the plant genome. Expression of the T-DNA-encoded oncogenes triggers proliferation and differentiation of transformed plant cells. Crown gall development is known to be accompanied by global changes in transcription, metabolite levels, and physiological processes. High levels of abscisic acid (ABA in crown galls regulate expression of drought stress responsive genes and mediate drought stress acclimation, which is essential for wild-type-like tumor growth. An impact of epigenetic processes such as DNA methylation on crown gall development has been suggested; however, it has not yet been investigated comprehensively. In this study, the methylation pattern of Arabidopsis thaliana crown galls was analyzed on a genome-wide scale as well as at the single gene level. Bisulfite sequencing analysis revealed that the oncogenes Ipt, IaaH, and IaaM were unmethylated in crown galls. Nevertheless, the oncogenes were susceptible to siRNA-mediated methylation, which inhibited their expression and subsequently crown gall growth. Genome arrays, hybridized with methylated DNA obtained by immunoprecipitation, revealed a globally hypermethylated crown gall genome, while promoters were rather hypomethylated. Mutants with reduced non-CG methylation developed larger tumors than the wild-type controls, indicating that hypermethylation inhibits plant tumor growth. The differential methylation pattern of crown galls and the stem tissue from which they originate correlated with transcriptional changes. Genes known to be transcriptionally inhibited by ABA and methylated in crown galls became promoter methylated upon treatment of A. thaliana with ABA. This suggests that the high ABA levels in crown galls may mediate DNA methylation and regulate expression of genes involved in drought stress protection. In summary, our studies provide evidence that epigenetic processes

  18. Design of a serotonin 4 receptor radiotracer with decreased lipophilicity for single photon emission computed tomography.

    Science.gov (United States)

    Fresneau, Nathalie; Dumas, Noé; Tournier, Benjamin B; Fossey, Christine; Ballandonne, Céline; Lesnard, Aurélien; Millet, Philippe; Charnay, Yves; Cailly, Thomas; Bouillon, Jean-Philippe; Fabis, Frédéric

    2015-04-13

    With the aim to develop a suitable radiotracer for the brain imaging of the serotonin 4 receptor subtype (5-HT4R) using single photon emission computed tomography (SPECT), we synthesized and evaluated a library of di- and triazaphenanthridines with lipophilicity values which were in the range expected to favour brain penetration, and which demonstrated specific binding to the target of interest. Adding additional nitrogen atoms to previously described phenanthridine ligands exhibiting a high unspecific binding, we were able to design a radioiodinated compound [(125)I]14. This compound exhibited a binding affinity value of 0.094 nM toward human 5-HT4R and a high selectivity over other serotonin receptor subtypes (5-HTR). In vivo SPECT imaging studies and competition experiments demonstrated that the decreased lipophilicity (in comparison with our previously reported compounds 4 and 5) allowed a more specific labelling of the 5-HT4R brain-containing regions. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  19. Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper

    Directory of Open Access Journals (Sweden)

    Susanne Merk

    2016-11-01

    Full Text Available This study investigates the retention load (RL between ZrO2 primary crowns and secondary polyetheretherketone (PEEK crowns made by different fabrication methods with three different tapers. Standardized primary ZrO2 crowns were fabricated with three different tapers: 0°, 1°, and 2° (n = 10/group. Ten secondary crowns were fabricated (i milled from breCam BioHPP blanks (PM; (ii pressed from industrially fabricated PEEK pellets (PP (BioHPP Pellet; or (iii pressed from granular PEEK (PG (BioHPP Granulat. One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé’s post-hoc test were used for data analysis (p < 0.05. Within crowns with a 0° taper, the PP group showed significantly higher retention load values compared with the other groups. Among the 1° taper, the PM group presented significantly lower retention loads than the PP group. However, the pressing type had no impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

  20. Impact of a drop onto a wetted wall: description of crown formation and propagation

    Science.gov (United States)

    Roisman, I. V.; Tropea, C.

    2002-12-01

    The impact of a drop onto a liquid film with a relatively high impact velocity, leading to the formation of a crown-like ejection, is studied theoretically. The motion of a kinematic discontinuity in the liquid film on the wall due to the drop impact, the formation of the upward jet at this kinematic discontinuity and its elevation are analysed. Four main regions of the drop and film are considered: the perturbed liquid film on the wall inside the crown, the unperturbed liquid film on the wall outside the crown, the upward jet forming a crown, and the free rim bounding this jet. The theory of Yarin & Weiss (1995) for the propagation of the kinematic discontinuity is generalized here for the case of arbitrary velocity vectors in the inner and outer liquid films on the wall. Next, the mass, momentum balance and Bernoulli equations at the base of the crown are considered in order to obtain the velocity and the thickness of the jet on the wall. Furthermore, the dynamic equations of motion of the crown are developed in the Lagrangian form. An analytical solution for the crown shape is obtained in the asymptotic case of such high impact velocities that the surface tension and the viscosity effects can be neglected in comparison to inertial effects. The edge of the crown is described by the motion of a rim, formed due to the surface tension.

  1. Lipophilized phenolics as antioxidants in fish oil enriched food systems

    DEFF Research Database (Denmark)

    Sørensen, Ann-Dorit Moltke; Nielsen, Nina Skall; Jacobsen, Charlotte

    Food products containing long chain omega-3 PUFA are highly susceptible to oxidation, which causes undesirable flavors and loss of health beneficial fatty acids. Many omega-3 enriched food products on the market are oil-in-water emulsions. According to the so called “polar paradox”, polar compounds...... hypothesis is that lipophilization of such polar phenolic compounds may improve their efficacy in fish oil enriched food systems. Our study aimed at evaluating rutin and dihydrocaffeic acid and their esters as antioxidants in o/w emulsion model system and milk enriched with fish oil. Moreover, the effect...

  2. Suitability of Secondary PEEK Telescopic Crowns on Zirconia Primary Crowns: The Influence of Fabrication Method and Taper.

    Science.gov (United States)

    Merk, Susanne; Wagner, Christina; Stock, Veronika; Eichberger, Marlis; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna

    2016-11-08

    This study investigates the retention load (RL) between ZrO₂ primary crowns and secondary polyetheretherketone (PEEK) crowns made by different fabrication methods with three different tapers. Standardized primary ZrO₂ crowns were fabricated with three different tapers: 0°, 1°, and 2° ( n = 10/group). Ten secondary crowns were fabricated (i) milled from breCam BioHPP blanks (PM); (ii) pressed from industrially fabricated PEEK pellets (PP) (BioHPP Pellet); or (iii) pressed from granular PEEK (PG) (BioHPP Granulat). One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé's post-hoc test were used for data analysis ( p impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.

  3. Effect of the structure, solid state and lipophilicity on the solubility of novel bicyclic derivatives

    International Nuclear Information System (INIS)

    Blokhina, Svetlana V.; Ol’khovich, Marina V.; Sharapova, Angelica V.; Volkova, Tatyana V.; Proshin, Alexey N.; Perlovich, German L.

    2014-01-01

    Highlights: • The solubility in buffer pH 7.4 of novel bicyclo-derivatives of amine were measured. • The influence of melting parameters and lipophilicity on the solubility was studied. • The thermodynamic parameters of the solubility process were calculated. - Abstract: Novel bicyclic derivatives have been synthesized. The solubility of drug-like substances in phosphate buffer rH 7.4 has been measured within the range of (9.02 · 10 −5 to 1.05 · 10 −4 ) mol/l. The relationship between the chemical nature and the structure of the aryl substituents and the solubility parameter was investigated. The fusion temperatures, enthalpies and entropies have been determined experimentally. The influence of thermophysical characteristics and lipophilicity on the solubility was studied using regression analysis. The calculations by the solubility/lipophilicity equation showed an overall improvement of the predictions equal to 0.5 log units. It was concluded that the solvation has a considerable influence on the solubility of the compounds under consideration. It was also determined that the alkyl- and halogen-derivatives solubility values correlate with HYBOT descriptors characterizing the (donor + acceptor) properties of the substances. The thermodynamic parameters of the solubility process were calculated using the temperature dependences. The study also revealed that the solubility of the bicyclic compounds is characterized by high endothermicity of the processes and negative entropies

  4. A Helix-Stabilizing Linker Improves Subcutaneous Bioavailability of a Helical Peptide Independent of Linker Lipophilicity

    Science.gov (United States)

    Zhang, Liang; Navaratna, Tejas; Thurber, Greg M.

    2016-01-01

    Stabilized peptides address several limitations to peptide-based imaging agents and therapeutics such as poor stability and low affinity due to conformational flexibility. There is also active research in developing these compounds for intracellular drug targeting, and significant efforts have been invested to determine the effects of helix stabilization on intracellular delivery. However, much less is known about the impact on other pharmacokinetic parameters such as plasma clearance and bioavailability. We investigated the effect of different fluorescent helix-stabilizing linkers with varying lipophilicity on subcutaneous (SC) bioavailability using the glucagon-like peptide-1 (GLP-1) receptor ligand exendin as a model system. The stabilized peptides showed significantly higher protease resistance and increased bioavailability independent of linker hydrophilicity, and all subcutaneously delivered conjugates were able to successfully target the islets of Langerhans with high specificity. The lipophilic peptide variants had slower absorption and plasma clearance than their respective hydrophilic conjugates, and the absolute bioavailability was also lower likely due to the longer residence times in the skin. The ease and efficiency of double-click helix stabilization chemistries is a useful tool for increasing the bioavailability of peptide therapeutics, many of which suffer from rapid in vivo protease degradation. Helix stabilization using linkers of varying lipophilicity can further control SC absorption and clearance rates to customize plasma pharmacokinetics. PMID:27327034

  5. Fracture toughness of zirconia ceramic crowns made by feather-edge tooth preparation design

    Directory of Open Access Journals (Sweden)

    Mirković Nemanja

    2012-01-01

    Full Text Available Background/Aim. Fracture toughness determines functional crown strenght and prevents damages on ceramics during mastication. There is a lack of relevant literature data about fracture toughness of crowns made by feather-edge preparation. Mechanical testing of ceramic samples is supposed to show if feather-edge tooth preparation is a successful method for making ceramic crowns without any risk of reduction of their mechanical properties. This research was done to establish effects of feather-edge tooth preparation on fracture toughness of single zirconia ceramic crowns. Methods. The research was performed as an experimental study. Sixty (60 ceramic crowns were made on non-carious extracted human premolars. Thirty (30 crowns were made on the basis of feather-edge preparation (experimental group I. The group II included 30 crowns made on 1 mm rounded shoulder. Crowns fabrication was executed on a copy mill production system “Zirkonzahn” (Zirkonzahn GMBH, Gais, Germany. The spherical compression test was used to determine fracture toughness, using 6 mm diameter ceramic ball. Fracture load for damaging ceramic crown was recorded on a universal testing machine - Zwick, type 1464, with the speed of 0.05 mm/min. Results. The results of this research introduced significant differences between fracture toughness of ceramic samples in every examined group. However, fracture toughness of crowns from both group was above 2 000 N, what was double beyond a recommended value. The mean value of fracture toughness in the feather-edge group was 2 090 N, and in shoulder group it was 2 214 N. Conclusion. This research showed a high fracture toughness of zirconia crowns made on feather-edge preparation. The examined crowns showed a fracture resistance at a sufficient distance in relation to the minimum values of functional loads. Further research of functional loads of these crown is necessary, as well as research of marginal adaptation of cemented crowns and

  6. Rock mechanics of crown pillars between cut-and-fill stopes at the Mount Isa mine

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M. F.; Bridges, M. C.

    1980-05-15

    At both levels, the leading stopes experienced bad ground conditions due to high stresses in the stope's backs when the crown pillars were about 35 m high. At 9 level, cut-and-fill mining stopped and most of the crown pillars were extracted by a slot-and-massfire method. At 11 level, cut-and-fill mining continued. Shear displacement along bedding planes began within and around the crown pillars of the leading stopes at 11 level, and spread through other crown pillars and to the hangingwall of the stoping system. Destressing and good ground conditions occurred where shear occurred, with further concentrations of stress in other areas. Crown pillars are being extracted to leave minimal 1:2 height to width diaphragms under the stopes above. Ground behavior of the 11 level crown pillars was investigated by observation, stress measurement, regional surveying of displacement and finite element models. An explanation of the ground behavior has evolved from this work. Bedding planes with an estimated angle of sliding friction of 10/sup 0/ were the main factor determining the behavior of this area.

  7. Canopy Fuel Load Mapping of Mediterranean Pine Sites Based on Individual Tree-Crown Delineation

    Directory of Open Access Journals (Sweden)

    Giorgos Mallinis

    2013-12-01

    Full Text Available This study presents an individual tree-crown-based approach for canopy fuel load estimation and mapping in two Mediterranean pine stands. Based on destructive sampling, an allometric equation was developed for the estimation of crown fuel weight considering only pine crown width, a tree characteristic that can be estimated from passive imagery. Two high resolution images were used originally for discriminating Aleppo and Calabrian pines crown regions through a geographic object based image analysis approach. Subsequently, the crown region images were segmented using a watershed segmentation algorithm and crown width was extracted. The overall accuracy of the tree crown isolation expressed through a perfect match between the reference and the delineated crowns was 34.00% for the Kassandra site and 48.11% for the Thessaloniki site, while the coefficient of determination between the ground measured and the satellite extracted crown width was 0.5. Canopy fuel load values estimated in the current study presented mean values from 1.29 ± 0.6 to 1.65 ± 0.7 kg/m2 similar to other conifers worldwide. Despite the modest accuracies attained in this first study of individual tree crown fuel load mapping, the combination of the allometric equations with satellite-based extracted crown width information, can contribute to the spatially explicit mapping of canopy fuel load in Mediterranean areas. These maps can be used among others in fire behavior prediction, in fuel reduction treatments prioritization and during active fire suppression.

  8. The effect of lipophilicity on the antibacterial activity of some 1-benzylbenzimidazole derivatives

    Directory of Open Access Journals (Sweden)

    D. J. BARNA

    2008-10-01

    Full Text Available In the present paper, the antibacterial activity of some 1-benzylbenzimidazole derivatives were evaluated against the Gram-negative bacteria Escherichia coli. The minimum inhibitory concentration was determined for all the compounds. Quantitative structure–activity relationship (QSAR was employed to study the effect of the lipophilicity parameters (log P on the inhibitory activity. Log P values for the target compounds were experimentally determined by the “shake-flask” method and calculated by using eight different software products. Multiple linear regression was used to correlate the log P values and antibacterial activity of the studied benzimidazole derivatives. The results are discussed based on statistical data. The most acceptable QSAR models for the prediction of the antibacterial activity of the investigated series of benzimidazoles were developed. High agreement between the experimental and predicted inhibitory values was obtained. The results of this study indicate that the lipophilicity parameter has a significant effect on the antibacterial activity of this class of compounds, which simplifies the design of new biologically active molecules.

  9. Experiments on the breakup of drop-impact crowns by Marangoni holes

    KAUST Repository

    Aljedaani, Abdulrahman Barakat

    2018-04-04

    We investigate experimentally the breakup of the Edgerton crown due to Marangoni instability when a highly viscous drop impacts on a thin film of lower-viscosity liquid, which also has different surface tension than the drop liquid. The presence of this low-viscosity film modifies the boundary condition, giving effective slip to the drop along the solid substrate. This allows the high-viscosity drop to form a regular bowl-shaped crown, which rises vertically away from the solid and subsequently breaks up through the formation of a multitude of Marangoni holes. Previous experiments have proposed that the breakup of the crown results from a spray of fine droplets ejected from the thin low-viscosity film on the solid, e.g. Thoroddsen et al. (J. Fluid Mech., vol. 557, 2006, pp. 63–72). These droplets can hit the inner side of the crown forming spots with lower surface tension, which drives a thinning patch leading to the hole formation. We test the validity of this assumption with close-up imaging to identify individual spray droplets, to show how they hit the crown and their lower surface tension drive the hole formation. The experiments indicate that every Marangoni-driven patch/hole is promoted by the impact of such a microdroplet. Surprisingly, in experiments with pools of higher surface tension, we also see hole formation. Here the Marangoni stress changes direction and the hole formation looks qualitatively different, with holes and ruptures forming in a repeatable fashion at the centre of each spray droplet impact. Impacts onto films of the same liquid, or onto an immiscible liquid, do not in general form holes. We furthermore characterize the effects of drop viscosity and substrate-film thickness on the overall evolution of the crown. We also measure the three characteristic velocities associated with the hole formation: i.e. the Marangoni-driven growth of the thinning patches, the rupture speed of the resulting thin films inside these patches and finally the

  10. Separation of americium (III) and strontium (II) using TEHDGA and 18-crown-6

    Energy Technology Data Exchange (ETDEWEB)

    Sinharoy, Prithwish; Khan, Pasupati Nath; Nair, Deepika; Jagasia, Poonam; Dhami, P.S.; Kaushik, C.P.; Banerjee, Kalyan [Bhabha Atomic Research Centre, Mumbai (India). Nuclear Recycle Group; Anitha, M. [Bhabha Atomic Research Centre, Mumbai (India). Rare Earth Development Section; Sharma, J.N. [Bhabha Atomic Research Centre, Mumbai (India). Process Development Div.

    2017-06-01

    This work describes extraction of Am(III) and Sr(II) together with tetra(2-ethylhexyl) diglycolamide (TEHDGA) and selective back-extraction of strontium with a strontium complexant, 18-crown-6, leading to their separation from each other. 0.3 M TEHDGA+5% isodecyl alcohol/n-dodecane was used to extract Am(III) and Sr(II) from 4 M nitric acid into organic phase with very high D (D{sub Am}=1000, D{sub Sr}=22) and 0.1 M 18-crown-6 dissolved in 4 M nitric acid is used for selective stripping of Sr(II) from loaded extract phase. Am(III) left in the extract phase was then stripped with 0.01 M nitric acid. Stripping of Sr(II) was found to increase with increase in 18-crown-6 concentration, at 0.1 M 18-crown-6 dissolved in 4 M nitric acid, 83% of the loaded strontium (D{sub Sr}=0.20) was back-extracted in a single contact while loss of Am(III) was 0.8% (D{sub Am}=122.45). Stoichiometry limit of 1:1 was observed between strontium and 18-crown-6. Strontium was precipitated and separated from the complexant by Na{sub 2}SO{sub 4} or Na{sub 2}CO{sub 3}. This process was tested with simulated solution of high level waste and found suitable for quantitative recovery of strontium with high purity.

  11. Effects of lipophilic components on the compatibility of lipid-based formulations with hard gelatin capsules.

    Science.gov (United States)

    Chen, Feng-Jing; Etzler, Frank M; Ubben, Johanna; Birch, Amy; Zhong, Li; Schwabe, Robert; Dudhedia, Mayur S

    2010-01-01

    The present study investigated the effect of lipophilic components on the compatibility of propylene glycol (PG)-containing lipid-based drug delivery system (LBDDS) formulations with hard gelatin capsules. The presence of a lipophilic active pharmaceutical ingredient (API) (log P approximately 6.1) and an additional lipophilic excipient (Capmul MCM) significantly affected the activity of PG in the fills and the equilibrium of PG between capsule shells and fills. These changes in activity and equilibrium of PG were furthermore correlated to the mechanical and thermal properties of the liquid-filled capsules and subsequently linked to the shelf-life of the capsules on stability with respect to capsule deformation. The present study also investigated the mechanism by which lipophilic component(s) might affect the activity of PG in the fill formulations and the equilibrium of PG between capsule shells and fills. The activities of PG in two series of "binary" mixtures with Capmul MCM and with Cremophor EL were measured, respectively. The mixtures of PG containing Capmul MCM were found to be more nearly ideal than those containing Cremophor EL. The observed negative deviation from Rauolt's law indicates that the excess free energies of mixing are less then zero indicating favorable interaction between PG and the other component. It is speculated that enhanced hydrogen bonding opportunities with Cremophor EL are responsible for the decreased excess free energy of mixing. Replacement of Cremophor EL with lipophilic API also reduces the hydrogen bonding opportunities for PG in the mixtures. This hypothesis may further explain the increased activity of PG in the fills and the shifted equilibrium of PG toward the capsule shells. Activity determination utilizing headspace gas chromatography (GC) using short 30 min incubation time seems to be a time-efficient approach for assessing capsule-fill compatibility. Direct measurements of PG migration and other physical properties of

  12. Lipophilic organic pollutants induce changes in phospholipid and membrane protein composition leading to Vero cell morphological change.

    Science.gov (United States)

    Liao, Ting T; Wang, Lei; Jia, Ru W; Fu, Xiao H; Chua, Hong

    2014-01-01

    Membrane damage related to morphological change in Vero cells is a sensitive index of the composite biotoxicity of trace lipophilic chemicals. However, judging whether the morphological change in Vero cells happens and its ratio are difficult because it is not a quantitative characteristic. To find biomarkers of cell morphological change for quantitatively representing the ratio of morphological changed cell, the mechanism of cell membrane damage driven by typical lipophilic chemicals, such as trichlorophenol (TCP) and perfluorooctanesulphonate (PFOS), was explored. The ratio of morphologically changed cells generally increased with increased TCP or PFOS concentrations, and the level of four major components of phospholipids varied with concentrations of TCP or PFOS, but only the ratio of phosphatidylcholine (PC)/phosphatidylethanolamine (PE) decreased regularly as TCP or PFOS concentrations increased. Analysis of membrane proteins showed that the level of vimentin in normal cell membranes is high, while it decreases or vanishes after TCP exposure. These variations in phospholipid and membrane protein components may result in membrane leakage and variation in rigid structure, which leads to changes in cell morphology. Therefore, the ratio of PC/PE and amount of vimentin may be potential biomarkers for representing the ratio of morphological changed Vero cell introduced by trace lipophilic compounds, thus their composite bio-toxicity.

  13. Review of Alberta Crown Crude Oil Marketing Program

    International Nuclear Information System (INIS)

    Crandall, G. R.; Kromm, R. B.

    1999-01-01

    This report contains an independent evaluation of the operations of the private marketing agents that are currently marketing the Alberta Crown's share of royalty crude oil. The evaluation includes a review of pricing performance, working relationship, current issues and the overall performance of the marketing arrangements during the fiscal years of 1997 and 1998. Overall, the outsourcing of sales of Crown production to agents is judged to be successful. For example, it has been noted that agents are becoming more aggressive in maintaining and increasing their margins. On the other hand, the increased level of aggressiveness in marketing, while tending to maximize Crown revenues, is also creating a potential conflict on how margins should be shared between the Crown and its agents. Also, there has been evidence of some management issues between the agents and the Crown concerning the extent to which the Crown should share in any increased value which the agent generates by increased third party marketing activities. These differences need to be addressed in order to maintain the strong performance of the marketing program. The consultants also recommend additional guidelines on risk management issues that more clearly define the Crown's risk tolerance. 2 tabs., 4 figs

  14. Studies on the lipophilicity of vehicles (or co-vehicles) and botanical oils used in cosmetic products.

    Science.gov (United States)

    Mbah, C J

    2007-05-01

    The lipophilic character of five vehicles (or co-vehicles): diethylhexylmaleate, dimethicone, light mineral oil, octyldodecanol and oleyl alcohol and eight botanical oils: Aloe vera oil, coconut oil, extra virgin olive oil, grape leaf oil, grape seed oil, hazelnut oil, jojoba oil and safflower oil was determined by partitioning esters of p-hydroxybenzoic acid (parabens) between them and phosphate buffer (pH 7.4). The results were compared to those obtained with 1-octanol. The most lipophilic effects were observed with octyldodecanol and oleyl alcohol for the vehicles (or co-vehicles), coconut oil, jojoba oil and safflower oil for botanical oils. Light mineral oil showed the least lipophilic effect. With butylparaben, it was observed that oleyl alcohol, octyldodecanol, coconut oil and jojoba oil were 0.94, 0.91, 0.74 and 0.68 times as lipophilic as 1-octanol respectively. The study indicates that octyldodecanol and oleyl alcohol could be good substitutes for 1-octanol in partition coefficient determination. The estimated permeability coefficients of the parabens suggest that octyldodecanol, oleyl alcohol, coconut oil and jojoba oil could be potential dermal permeation enhancers.

  15. Experimental and numerical modeling of shrub crown fire initiation

    Science.gov (United States)

    Watcharapong Tachajapong; Jesse Lozano; Shakar Mahalingam; Xiangyang Zhou; David Weise

    2009-01-01

    The transition of fire from dry surface fuels to wet shrub crown fuels was studied using laboratory experiments and a simple physical model to gain a better understanding of the transition process. In the experiments, we investigated the effects of varying vertical distances between surface and crown fuels (crown base height), and of the wind speed on crown fire...

  16. An in-vitro investigation of the accuracy of fit of Procera and Empress crowns.

    Science.gov (United States)

    Fleming, Garry J R; Dobinson, Marie M; Landini, Gabriel; Harris, Jonathan J

    2005-09-01

    The current study aimed to investigate the accuracy of fit and the reproducibility of inner crown profile for two types of high strength ceramics, IPS Empress and Procera. Procera and Empress crowns with four different morphologies were cemented to dies using zinc phosphate dental cement. Vertical and horizontal sections were made through each of the crown/die preparations and images of the vertical sections were compared for curvature reproduction by alignment using image processing. Measurements were made on horizontal sections to determine cement layer thickness. Alignment of the crowns using image analysis identified quantifiable variations in the inner surface profile compared with the outer surface of the die. The largest differences occurred from the cusp tips to the occlusal adaptation area and differences in surface profile were less pronounced for Procera than Empress crowns. Marginal gap varied independently of ceramic or internal crown shape from 7-529 microm for Procera and 26-548 microm for Empress. IPS Empress has a superior ability to reproduce the inner surface profile of the crown morphologies investigated compared with Procera. The reduced reproduction of surface profile was associated with an increased cement thickness at the occlusal contact area that may inadvertently lead to failure of the crowns functional characteristics.

  17. A sun-crown-sensor model and adapted C-correction logic for topographic correction of high resolution forest imagery

    Science.gov (United States)

    Fan, Yuanchao; Koukal, Tatjana; Weisberg, Peter J.

    2014-10-01

    Canopy shadowing mediated by topography is an important source of radiometric distortion on remote sensing images of rugged terrain. Topographic correction based on the sun-canopy-sensor (SCS) model significantly improved over those based on the sun-terrain-sensor (STS) model for surfaces with high forest canopy cover, because the SCS model considers and preserves the geotropic nature of trees. The SCS model accounts for sub-pixel canopy shadowing effects and normalizes the sunlit canopy area within a pixel. However, it does not account for mutual shadowing between neighboring pixels. Pixel-to-pixel shadowing is especially apparent for fine resolution satellite images in which individual tree crowns are resolved. This paper proposes a new topographic correction model: the sun-crown-sensor (SCnS) model based on high-resolution satellite imagery (IKONOS) and high-precision LiDAR digital elevation model. An improvement on the C-correction logic with a radiance partitioning method to address the effects of diffuse irradiance is also introduced (SCnS + C). In addition, we incorporate a weighting variable, based on pixel shadow fraction, on the direct and diffuse radiance portions to enhance the retrieval of at-sensor radiance and reflectance of highly shadowed tree pixels and form another variety of SCnS model (SCnS + W). Model evaluation with IKONOS test data showed that the new SCnS model outperformed the STS and SCS models in quantifying the correlation between terrain-regulated illumination factor and at-sensor radiance. Our adapted C-correction logic based on the sun-crown-sensor geometry and radiance partitioning better represented the general additive effects of diffuse radiation than C parameters derived from the STS or SCS models. The weighting factor Wt also significantly enhanced correction results by reducing within-class standard deviation and balancing the mean pixel radiance between sunlit and shaded slopes. We analyzed these improvements with model

  18. Crown sealing and buckling instability during water entry of spheres

    KAUST Repository

    Marston, J. O.

    2016-04-05

    We present new observations from an experimental investigation of the classical problem of the crown splash and sealing phenomena observed during the impact of spheres onto quiescent liquid pools. In the experiments, a 6 m tall vacuum chamber was used to provide the required ambient conditions from atmospheric pressure down to of an atmosphere, whilst high-speed videography was exploited to focus primarily on the above-surface crown formation and ensuing dynamics, paying particular attention to the moments just prior to the surface seal. In doing so, we have observed a buckling-type azimuthal instability of the crown. This instability is characterised by vertical striations along the crown, between which thin films form that are more susceptible to the air flow and thus are drawn into the closing cavity, where they atomize to form a fine spray within the cavity. To elucidate to the primary mechanisms and forces at play, we varied the sphere diameter, liquid properties and ambient pressure. Furthermore, a comparison between the entry of room-temperature spheres, where the contact line pins around the equator, and Leidenfrost spheres (i.e. an immersed superheated sphere encompassed by a vapour layer), where there is no contact line, indicates that the buckling instability appears in all crown sealing events, but is intensified by the presence of a pinned contact line. © 2016 Cambridge University Press.

  19. Fracture Strength of Aged Monolithic and Bilayer Zirconia-Based Crowns

    Directory of Open Access Journals (Sweden)

    Deborah Pacheco Lameira

    2015-01-01

    Full Text Available The purpose of this study was to evaluate the effect of design and surface finishing on fracture strength of yttria-tetragonal zirconia polycrystal (Y-TZP crowns in monolithic (1.5 mm thickness and bilayer (0.8 mm zirconia coping and 0.7 mm porcelain veneer configuration after artificial aging. Bovine incisors received crown preparation and Y-TZP crowns were manufactured using CAD/CAM technique, according to the following groups (n=10: Polished monolithic zirconia crowns (PM; Glazed monolithic zirconia crowns (GM; Bi-layer crowns (BL. Crowns were cemented with resin cement, submitted to artificial aging in a chewing simulator (2.5 million cycles/80 N/artificial saliva/37°C, and tested for fracture strength. Two remaining crowns referring to PM and GM groups were submitted to a chemical composition analysis to measure the level of yttrium after aging. One-way ANOVA and Tukey’s test (P=.05 indicated that monolithic zirconia crowns presented similar fracture strength (PM=3476.2 N ± 791.7; GM=3561.5 N ± 991.6, which was higher than bilayer crowns (2060.4 N ± 810.6. There was no difference in the yttrium content among the three surfaces evaluated in the monolithic crowns. Thus, monolithic zirconia crowns present higher fracture strength than bilayer veneered zirconia after artificial aging and surface finishing does not affect their fracture strength.

  20. Improved method for estimating tree crown diameter using high-resolution airborne data

    Czech Academy of Sciences Publication Activity Database

    Brovkina, Olga; Latypov, I. Sh.; Cienciala, E.; Fabiánek, Tomáš

    2016-01-01

    Roč. 10, č. 2 (2016), č. článku 026006. ISSN 1931-3195 R&D Projects: GA MŠk(CZ) LO1415 Institutional support: RVO:67179843 Keywords : mixed forest * crown size * airborne data * automatic processing Subject RIV: EH - Ecology, Behaviour Impact factor: 1.107, year: 2016

  1. Evaluation of sampling strategies to estimate crown biomass

    Science.gov (United States)

    Krishna P Poudel; Hailemariam Temesgen; Andrew N Gray

    2015-01-01

    Depending on tree and site characteristics crown biomass accounts for a significant portion of the total aboveground biomass in the tree. Crown biomass estimation is useful for different purposes including evaluating the economic feasibility of crown utilization for energy production or forest products, fuel load assessments and fire management strategies, and wildfire...

  2. Enzymatic lipophilization of epicatechin with free fatty acids and its effect on antioxidative capacity in crude camellia seed oil.

    Science.gov (United States)

    Chen, Sa-Sa; Luo, Shui-Zhong; Zheng, Zhi; Zhao, Yan-Yan; Pang, Min; Jiang, Shao-Tong

    2017-02-01

    Crude camellia seed oil is rich in free fatty acids, which must be removed to produce an oil of acceptable quality. In the present study, we reduced the free fatty acid content of crude camellia seed oil by lipophilization of epicatechin with these free fatty acids in the presence of Candida antarctica lipase B (Novozym 435), and this may enhance the oxidative stability of the oil at the same time. The acid value of crude camellia seed oil reduced from 3.7 to 2.5 mgKOH g -1 after lipophilization. Gas chomatography-mass spectrometry analysis revealed that epicatechin oleate and epicatechin palmitate were synthesized in the lipophilized oil. The peroxide, p-anisidine, and total oxidation values during heating of the lipophilized oil were much lower than that of the crude oil and commercially available camellia seed oil, suggesting that lipophilized epicatechin derivatives could help enhance the oxidative stability of edible oil. The enzymatic process to lipophilize epicatechin with the free fatty acids in crude camellia seed oil described in the present study could decrease the acid value to meet the quality standards for commercial camellia seed oil and, at the same time, obtain a new edible camellia seed oil product with good oxidative stability. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  3. Characterization of Microsolvated Crown Ethers from Broadband Rotational Spectroscopy

    Science.gov (United States)

    Perez, Cristobal; Schnell, Melanie; Blanco, Susana; Lopez, Juan Carlos

    2016-06-01

    Since they were first synthetized, crown ethers have been extensively used in organometallic chemistry due to their unparalleled binding selectivity with alkali metal cations. From a structural point of view, crown ethers are heterocycles containing oxygen and/or other heteroatoms, although the most common ones are formed from ethylene oxide unit. Crown ethers are conventionally seen as being hydrophilic inside and hydrophobic outside when the structures found for the metal cation complexes are considered. However, crown ethers are extremely flexible and in isolation may present a variety of stable conformations so that their structure may be easily adapted in presence of a strong ligand as an alkali metal cation minimize the energy of the resulting complex. Water can be considered a soft ligand which interacts with crown ethers through moderate hydrogen bonds. It is thus interesting to investigate which conformers are selected by water to form complexes, the preferred interaction sites and the possible conformational changes due to the presence of one or more water molecules. Previous studies identified microsolvated crown ethers but in all cases with a chromophore group attached to the structure. Here we present a broadband rotational spectroscopy study of microsolvated crown ethers produced in a pulsed molecular jet expansion. Several 1:1 and 1:2 crown ether:water aggregates are presented for 12-crown-4, 15-crown-5 and 18-crown-6. Unambiguous identification of the structures has been achieved using isotopic substitution within the water unit. The subtle changes induced in the structures of the crown ether monomer upon complexation and the hydrogen-bonding network that hold them together will be also discussed. F. Gámez, B. Martínez-Haya, S. Blanco,J. C. López and J. L. Alonso, Phys. Chem. Chem. Phys. 2014, 14 12912-12918 V. A. Shubert, C.W. Müller and T. Zwier, J. Phys. Chem. A 2009, 113 8067-8079

  4. Another one bites the dust: faecal silica levels in large herbivores correlate with high-crowned teeth

    Science.gov (United States)

    Hummel, Jürgen; Findeisen, Eva; Südekum, Karl-Heinz; Ruf, Irina; Kaiser, Thomas M.; Bucher, Martin; Clauss, Marcus; Codron, Daryl

    2011-01-01

    The circumstances of the evolution of hypsodonty (= high-crowned teeth) are a bone of contention. Hypsodonty is usually linked to diet abrasiveness, either from siliceous phytoliths (monocotyledons) or from grit (dusty environments). However, any empirical quantitative approach testing the relation of ingested silica and hypsodonty is lacking. In this study, faecal silica content was quantified as acid detergent insoluble ash and used as proxy for silica ingested by large African herbivores of different digestive types, feeding strategies and hypsodonty levels. Separate sample sets were used for the dry (n = 15 species) and wet (n = 13 species) season. Average faecal silica contents were 17–46 g kg−1 dry matter (DM) for browsing and 52–163 g kg−1 DM for grazing herbivores. No difference was detected between the wet (97.5 ± 14.4 g kg−1 DM) and dry season (93.5 ± 13.7 g kg−1 DM) faecal silica. In a phylogenetically controlled analysis, a strong positive correlation (dry season r = 0.80, p < 0.0005; wet season r = 0.74, p < 0.005) was found between hypsodonty index and faecal silica levels. While surprisingly our results do not indicate major seasonal changes in silica ingested, the correlation of faecal silica and hypsodonty supports a scenario of a dominant role of abrasive silica in the evolution of high-crowned teeth. PMID:21068036

  5. Clinical examination of leucite-reinforced glass-ceramic crowns (Empress) in general practice: a retrospective study.

    Science.gov (United States)

    Sjögren, G; Lantto, R; Granberg, A; Sundström, B O; Tillberg, A

    1999-01-01

    The purpose of this study was to retrospectively evaluate leucite reinforced-glass ceramic crowns (Empress) placed in patients who regularly visit general practices. One hundred ten Empress crowns, placed in 29 patients who visited a general practice on a regular basis, were evaluated according to the California Dental Association's (CDA) quality evaluation system. In addition, the occurrence of plaque and certain gingival conditions was evaluated. All crowns were luted with resin composite cement. The mean and median years in function for the crowns were 3.6 and 3.9 years, respectively. Based on the CDA criteria, 92% of the 110 crowns were rated "satisfactory." Eighty-six percent were given the CDA rating "excellent" for margin integrity. Fracture was registered in 6% of the 110 crowns. Of the remaining 103 crowns, the CDA rating excellent was given to 74% for anatomic form, 86% for color, and 90% for surface. No significant differences (P > 0.05) were observed regarding fracture rates between anterior and posterior crowns. With regard to the occurrence of plaque and bleeding on probing, no significant differences (P > 0.05) were observed between the Empress crowns and the controls. Most of the fractured crowns had been placed on molars or premolars. Although the difference between anterior and posterior teeth was not statistically significant with respect to the fracture rates obtained, the number of fractured crowns placed on posterior teeth exceeded that of those placed on anterior teeth. The difference between the fracture rates may have clinical significance, and the risk of fracture has to be taken into consideration when placing crowns on teeth that are likely to be subjected to high stress levels.

  6. An alternative method for estimating crown characteristics of urban trees using digital photographs

    Science.gov (United States)

    Matthew F. Winn; Philip A. Araman

    2012-01-01

    The USDA Forest Service Forest Inventory and Analysis (FIA) program has concluded that statewide urban forest inventories are feasible based on a series of pilot studies initiated in 2001. However, much of the tree crown data collected during inventories are based on visual inspection and therefore highly subjective. In order to objectively determine the crown...

  7. Digital photography for urban street tree crown conditions

    Science.gov (United States)

    Neil A. Clark; Sang-Mook Lee; William A. Bechtold; Gregory A. Reams

    2006-01-01

    Crown variables such as height, diameter, live crown ratio, dieback, transparency, and density are all collected as part of the overall crown assessment (USDA 2004). Transparency and density are related to the amount of foliage and thus the photosynthetic potential of the tree. These measurements are both currently based on visual estimates and have been shown to be...

  8. Crown Fire Potential

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — Crown fire potential was modeled using FlamMap, an interagency fire behavior mapping and analysis program that computes potential fire behavior characteristics. The...

  9. Longevity of metal-ceramic crowns cemented with self-adhesive resin cement: a prospective clinical study

    Science.gov (United States)

    Brondani, Lucas Pradebon; Pereira-Cenci, Tatiana; Wandsher, Vinicius Felipe; Pereira, Gabriel Kalil; Valandro, Luis Felipe; Bergoli, César Dalmolin

    2017-04-10

    Resin cements are often used for single crown cementation due to their physical properties. Self-adhesive resin cements gained widespread due to their simplified technique compared to regular resin cement. However, there is lacking clinical evidence about the long-term behavior of this material. The aim of this prospective clinical trial was to assess the survival rates of metal-ceramic crowns cemented with self-adhesive resin cement up to six years. One hundred and twenty-nine subjects received 152 metal-ceramic crowns. The cementation procedures were standardized and performed by previously trained operators. The crowns were assessed as to primary outcome (debonding) and FDI criteria. Statistical analysis was performed using Kaplan-Meier statistics and descriptive analysis. Three failures occurred (debonding), resulting in a 97.6% survival rate. FDI criteria assessment resulted in scores 1 and 2 (acceptable clinical evaluation) for all surviving crowns. The use of self-adhesive resin cement is a feasible alternative for metal-ceramic crowns cementation, achieving high and adequate survival rates.

  10. Solvent Effects on Cesium Complexation with Crown Ethers from Liquid to Supercritical Fluids

    International Nuclear Information System (INIS)

    Wai, Chien M.; Rustenholtz, Anne; Wang, Shaofen; Lee, Su-Chen; Herman, Jamie; Porter, Richard A.

    2004-01-01

    Nuclear magnetic resonance (NMR) techniques were used to study crown ether-water interactions in solvents of low dielectric constants such as chloroform and carbon tetrachloride. Water forms a 1:1 complex with a number of crown ethers including 12-crown-4, 15-crown-5, 18-crown-6, dicyclohexano-18=crown-6, dicyclohexano-24-crown 8, and dibenzl-24-crown-8 in chloroform. Among these crown ethers, the 18-crown-6-H2 complex has the largest equilibrium constant (K=545) and 97% of the crown is complexed to water in chloroform. Addition of carbon tetrachloride to chloroform lowers the equilibrium constants of the crown-water complexes. The partition coefficients of crown ethers (D=crown in water/crown in solvent) between water and organic solvent also vary with solvent composition

  11. Descriptive statistics of tree crown condition in the Northeastern United States

    Science.gov (United States)

    KaDonna C. Randolph; Randall S. Morin; Jim Steinman

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Connecticut, Delaware, Maine, Maryland, Massachusetts, New...

  12. Fracture rates of IPS Empress all-ceramic crowns--a systematic review.

    Science.gov (United States)

    Heintze, Siegward D; Rousson, Valentin

    2010-01-01

    The aim of this study was to evaluate the clinical fracture rate of crowns fabricated with the pressable, leucite-reinforced ceramic IPS Empress, and relate the results to the type of tooth restored. The database SCOPUS was searched for clinical studies involving full-coverage crowns made of IPS Empress. To assess the fracture rate of the crowns in relation to the type of restored tooth and study, Poisson regression analysis was used. Seven clinical studies were identified involving 1,487 adhesively luted crowns (mean observation time: 4.5+/-1.7 years) and 81 crowns cemented with zinc-phosphate cement (mean observation time: 1.6+/-0.8 years). Fifty-seven of the adhesively luted crowns fractured (3.8%). The majority of fractures (62%) occurred between the third and sixth year after placement. There was no significant influence regarding the test center on fracture rate, but the restored tooth type played a significant role. The hazard rate (per year) for crowns was estimated to be 5 in every 1,000 crowns for incisors, 7 in every 1,000 crowns for premolars, 12 in every 1,000 crowns for canines, and 16 in every 1,000 crowns for molars. One molar crown in the zinc-phosphate group fractured after 1.2 years. Adhesively luted IPS Empress crowns showed a low fracture rate for incisors and premolars and a somewhat higher rate for molars and canines. The sample size of the conventionally luted crowns was too small and the observation period too short to draw meaningful conclusions.

  13. Bioavailability assessment of the lipophilic benfotiamine as compared to a water-soluble thiamin derivative.

    Science.gov (United States)

    Bitsch, R; Wolf, M; Möller, J; Heuzeroth, L; Grüneklee, D

    1991-01-01

    The bioequivalence of thiamin in 2 therapeutically used preparations was tested in 10 healthy young men. Thiamin was orally administered either as lipophilic benfotiamine or as water-soluble thiamin mononitrate. Biokinetic data, measured as area under the curve and maximal concentration in plasma and hemolysate after ingestion, demonstrated a significantly improved bioavailability from the lipophilic derivative despite an ingested dose of only 40% as compared with the water-soluble salt. A superior cellular efficacy of benfotiamine was also concluded from the short-term stimulation of the thiamin-dependent transketolase activity in erythrocytes.

  14. [Finite element analysis of the maxillary central incisor with traditional and modified crown lengthening surgery and post-core restoration in management of crown-root fracture].

    Science.gov (United States)

    Zhen, M; Wei, Y P; Hu, W J; Rong, Q G; Zhang, H

    2016-06-01

    To construct three-dimensional finite element models with modified crown lengthening surgery and post-core restoration in management of various crown-root fracture types, to investigate the intensity and distribution of stressin models mentioned above, and to compare and analyze the indications of traditional and modified crown lengthening surgeries from the mechanic point of view. Nine three-dimensional finite element models with modified crown lengthening surgery and post-core restoration were established and analyzed by micro-CT scanning technique, dental impression scanner, Mimics 10.0, Geomagic studio 9.0 and ANSYS 14.0 software. The von Mises stress of dentin, periodontal ligament, alveolar bone, post and core, as well as the periodontal ligament area and threshold limit value were calculated and compared with the findings of traditional crown lengthening models which had been published earlierby our research group. The von Mises stress intensity of modified crown lengthening models were: dentin>post>core>alveolar bone>periodontal ligament. The maximum von Mises stress of dentin(44.37-80.58 MPa)distributed in lingual central shoulder. The periodontal ligament area of the modified crown lengthening surgery was reduced by 6% to 28%, under the same crown-root fracture conditions, the periodontal ligament area of modified crown lengthening models was larger than that of the traditional crown lengthening models. In modified crown lengthening surgery models, the von Mises stress of periodontal ligament of B3L1m, B3L2m, B3L3m models exceeded their limit values, however, the von Mises stress of periodontal ligament of the B2L2c, B2L3c, B3L1c, B3L2c, B3L3c models exceeded their limit values in traditional crown lengthening surgery models. The modified crown lengthening surgery conserves more periodontal supporting tissues, which facilitates the long-term survival of teeth. The indication of modified crown lengthening surgery is wider than traditional method. The

  15. Navigating through the Crown land process

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, M. [Samsung Renewable Energy Inc., ON (Canada)

    2010-07-01

    Samsung Communications and Technology (Samsung C and T) and the Korea Electric Power Corporation are planning to invest approximately $7 billion to generate 2500 MW of wind and solar energy in Ontario. The plan was centred around the green energy investment agreement signed in January 2010. To date, only 1 project in Ontario has been permitted for development on Crown land, and there have been 3 different versions of the Crown land policy and procedure for the development of wind power projects. The Crown land process is challenged by issues related to grandfathering, timing, competing processes, and the Endangered Species Act. Guidance is needed to identify requirements for studies and evaluation processes. Additional studies are often required by government agencies when new documents and results are reviewed. Projects are also delayed when new species are added to the endangered species list. Wind power developers must keep abreast of proposed regulations and guidelines to ensure that work programs are not delayed. An overview of the current Crown land development process was included. tabs., figs.

  16. [A ten-year clinical study of cracked teeth restored with glass ceramic crowns].

    Science.gov (United States)

    Luo, X P; Yuan, Y; Shi, Y J; Qian, D D

    2016-10-09

    Objective: To evaluate the clinic performance of high strength glass ceramic crowns for the painful cracked teeth during a 10-year observation period. Methods: Forty-two posterior teeth from 36 patients were diagnosed as having a crack, biting painful and sensitivity to cold were selected in the Department of Prosthodontic, Institute and Hospital of Stomatology, Nanjing University Medical School. The lost-wax hot pressed glass ceramic crowns were bonded on the minimally invasive prepared teeth by modern adhesive technology. Patients were interviewed and went through clinic examination after one week, one month, and every six months. Results: The effectiveness of 42 glass ceramic crowns for cracked teeth was evaluated for a mean observation time over 10-year. At the first week, 29(81%) patients were free of pain, three still had sensitivity to cold and chewing pain, three still had sensitivity to cold, one had painful to cold and hot. After one month, two patients still had chewing pain, and one tooth needed endodontic treatment after six months. In 10 years, 2(5%) all ceramic crowns were broken, the other 40 restorations kept good clinical performances with a 10-year survival rate of 95%. Conclusions: The high strength glass ceramic crowns are very effective and successful in treating the cracked teeth and then keep the good mastication function and appearance.

  17. Fatigue resistance of CAD/CAM resin composite molar crowns.

    NARCIS (Netherlands)

    Shembish, F.A.; Tong, H.; Kaizer, M.; Janal, M.N.; Thompson, V.P.; Opdam, N.J.M.; Zhang, Y.

    2016-01-01

    OBJECTIVE: To demonstrate the fatigue behavior of CAD/CAM resin composite molar crowns using a mouth-motion step-stress fatigue test. Monolithic leucite-reinforced glass-ceramic crowns were used as a reference. METHODS: Fully anatomically shaped monolithic resin composite molar crowns (Lava

  18. Fracture Resistance Force of Primary Molar Crowns Milled from ...

    African Journals Online (AJOL)

    2018-04-04

    Apr 4, 2018 ... molar stainless steel crown (SSC) and stored in water at 37°C for 30 days. The crowns were seated on Cr‑Co ... model) or chairside (in‑office system model) CAD/ ..... crowns, deformation may be observed instead of fracture.

  19. Bis(hydroxyammonium hexachloridoplatinate(IV–18-crown-6 (1/2

    Directory of Open Access Journals (Sweden)

    Evgeny Bulatov

    2014-01-01

    Full Text Available In the title complex, (NH3OH2[PtCl6]·2C12H24O6, the PtIV atom is coordinated by six chloride anions in a slightly distorted octahedral geometry. The Pt—Cl bond lengths are comparable to those reported for other hexachloridoplatinate(IV species. The hydroxyammonium groups act as linkers between the [PtCl6]2− anion and the crown ether molecules. The anion is linked to two hydroxyammonium cations via O—H...Cl hydrogen bonds and each hydroxyammonium moiety is linked to a crown ether molecule by hydrogen bonds between ammonium H atoms and 18-crown-6 O atoms. The crown ether molecules have the classic crown shape in which all O atoms are located in the inner part of the crown ether ring and all –CH2– groups are turned to the outside.

  20. AB INITIO INVESTIGATION OF 12-CROWN-4 AND BENZO-12-CROWN-4 COMPLEXES WITH Li+, Na+, K+, Zn2+, Cd2+, AND Hg2+

    Directory of Open Access Journals (Sweden)

    Yahmin Yahmin

    2010-06-01

    Full Text Available The structure and binding energies of 12-crown-4 and benzo-12-crown-4 complexes with Li+, Na+, K+, Zn2+, Cd2+, and Hg2+were investigated with ab initio calculations using Hartree-Fock approximation and second-order perturbation theory. The basis set used in this study is lanl2mb. The structure optimization of cation-crown ether complexes was evaluated at HF/lanl2mb level of theory and interaction energy of the corresponding complexes was calculated at MP2/lanl2mb level of theory (MP2/lanl2mb//HF/lanl2mb. Interactions of the crown ethers and the cations were discussed in term of the structure parameter of crown ether. The binding energies of the complexes show that all complex formed from transition metal cations is more stable than the complexes formed from alkali metal cations.   Keywords: 12-crown-4, benzo-12-crown-4, alkali metals, transition metals

  1. Retention Load Values of Telescopic Crowns Made of Y-TZP and CoCr with Y-TZP Secondary Crowns: Impact of Different Taper Angles

    Directory of Open Access Journals (Sweden)

    Susanne Merk

    2016-05-01

    Full Text Available This study aimed to examine and compare the retention load values (RL of different telescopic crown assemblies (Y-TZP and CoCr primary crowns with electroformed and Y-TZP secondary crowns each with three different taper angles (0°, 1° and 2°. Thirty Y-TZP primary crowns with electroformed gold copings (Z/G group and Y-TZP secondary crowns (Z/Z group and 30 CoCr primary crowns with electroformed gold copings (C/G group and Y-TZP secondary crowns (C/Z group, each with taper angles of 0°, 1° and 2°, were fabricated, respectively. With the exception of the electroformed gold copings, all specimens were Computer-Aided-Design/Computer-Aided-Manufacturing (CAD/CAM-milled, then sintered and afterwards manually adapted. In order to stabilize the gold copings, they were fixed in a tertiary structure. The secondary crowns were constructed with a hook, which ensured self-alignment with an upper chain. Afterwards, 20 pull-off test cycles were performed in a universal testing machine under artificial saliva and after weighing the secondary crowns with a 5 kg object for 20 s. Data were analyzed by one-way and two-way Analysis of Variance (ANOVA. C/Z with 1° showed higher (p = 0.009 RL than 0° and 2° tapers. C/G at 1° also showed higher (p = 0.001 RL than at tapers of 0° and 2°. Z/G and C/G at 0° showed lower RL than Z/Z and C/Z (p < 0.001. Primary crowns had no impact on the 0° group. Z/G showed lower RL as compared to C/Z within the 1° group (p = 0.007 and Z/Z in the 2° group (p = 0.006. The primary crown material had no influence on RL. Electroformed copings showed lower RL. Further investigations for 1° as well as for the long-term performance after thermomechanical aging are necessary.

  2. New atraumatic easy removal technique for permanently cemented crown

    Directory of Open Access Journals (Sweden)

    Pravinkumar G Patil

    2012-01-01

    Full Text Available Removal of a permanently cemented crown or fixed partial denture is a cumbersome procedure for a prosthodontist, especially when there is no purchase point available to remove it. The technique described in this article consists of sectioning of a crown on facial surface followed by removal of the crown with orthodontic plier. This technique does not damage the gingival/periodontal tissues or underlying tooth structure as the crown need not to be removed with jerky back-action force.

  3. Root-Crown Relations of Young Sugar Maple and Yellow Birch

    Science.gov (United States)

    Carl H. Tubbs

    1977-01-01

    Young forest-grown sugar maple and yellow birch (1 to 6 inches d.b.h.) crowns were mapped and roots excavated. Crown dimensions were compared. Sugar maple roots usually terminated within a few feet of the crown perimeter. Yellow birch roots frequently terminated well outside crown perimeters and roots of birch were more irregularly distributed than those of maple....

  4. A short-term clinical evaluation of IPS Empress 2 crowns.

    Science.gov (United States)

    Toksavul, Suna; Toman, Muhittin

    2007-01-01

    The aim of this study was to evaluate the clinical performance of all-ceramic crowns made with the IPS Empress 2 system after an observation period of 12 to 60 months. Seventy-nine IPS Empress 2 crowns were placed in 21 patients. The all-ceramic crowns were evaluated clinically, radiographically, and using clinical photographs. The evaluations took place at baseline (2 days after cementation) and at 6-month intervals for 12 to 60 months. Survival rate of the crowns was determined using Kaplan-Meier statistical analysis. Based on the US Public Health Service criteria, 95.24% of the crowns were rated satisfactory after a mean follow-up period of 58 months. Fracture was registered in only 1 crown. One endodontically treated tooth failed as a result of fracture at the cervical margin area. In this in vivo study, IPS Empress 2 crowns exhibited a satisfactory clinical performance during an observation period ranging from 12 to 60 months.

  5. Longevity of metal-ceramic crowns cemented with self-adhesive resin cement: a prospective clinical study

    Directory of Open Access Journals (Sweden)

    Lucas Pradebon BRONDANI

    2017-04-01

    Full Text Available Abstract Resin cements are often used for single crown cementation due to their physical properties. Self-adhesive resin cements gained widespread due to their simplified technique compared to regular resin cement. However, there is lacking clinical evidence about the long-term behavior of this material. The aim of this prospective clinical trial was to assess the survival rates of metal-ceramic crowns cemented with self-adhesive resin cement up to six years. One hundred and twenty-nine subjects received 152 metal-ceramic crowns. The cementation procedures were standardized and performed by previously trained operators. The crowns were assessed as to primary outcome (debonding and FDI criteria. Statistical analysis was performed using Kaplan-Meier statistics and descriptive analysis. Three failures occurred (debonding, resulting in a 97.6% survival rate. FDI criteria assessment resulted in scores 1 and 2 (acceptable clinical evaluation for all surviving crowns. The use of self-adhesive resin cement is a feasible alternative for metal-ceramic crowns cementation, achieving high and adequate survival rates.

  6. Twenty-nine-month follow-up of a paediatric zirconia dental crown.

    Science.gov (United States)

    Lopez Cazaux, Serena; Hyon, Isabelle; Prud'homme, Tony; Dajean Trutaud, Sylvie

    2017-06-14

    The aim of this paper is to present the long-term follow-up of one paediatric zirconia crown on a deciduous molar. Preformed crowns are part of the armamentarium in paediatric dentistry. In recent years, aesthetic alternatives to preformed metal crowns have been developed, first preveneered crowns and then zirconia crowns. This paper describes the restoration of a primary molar with a zirconia crown (EZ-Pedo, Loomis, California, USA) in an 8-year-old boy. In this clinical case, the protocol for the implementation and maintenance of zirconia crowns is detailed. The patient was followed up for 29 months until the natural exfoliation of his primary molar. The adaptation of the zirconia crown, the gingival health and the wear on the opposing tooth were considered. In this case, the paediatric zirconia crown allowed sustainable functional restoration while restoring a natural appearance of the tooth. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  7. Re/crowning the Jowo Śākyamuni

    DEFF Research Database (Denmark)

    Warner, Cameron

    2011-01-01

    of ritual observance and visions received.  In 1409, Tsongkhapa Lozang Drakpa  (1357-1419) crowned the Jowo, changing his doctrinal and iconographic representations.  I connect the controversy surrounding Tsongkhapa's decision to re/crown the Jowo in 1409 to the significance placed on authenticity...

  8. Bioactive Phytochemicals from Wild Arbutus unedo L. Berries from Different Locations in Portugal: Quantification of Lipophilic Components.

    Science.gov (United States)

    Fonseca, Daniela F S; Salvador, Ângelo C; Santos, Sónia A O; Vilela, Carla; Freire, Carmen S R; Silvestre, Armando J D; Rocha, Sílvia M

    2015-06-23

    The lipophilic composition of wild Arbutus unedo L. berries, collected from six locations in Penacova (center of Portugal), as well as some general chemical parameters, namely total soluble solids, pH, titratable acidity, total phenolic content and antioxidant activity was studied in detail to better understand its potential as a source of bioactive compounds. The chemical composition of the lipophilic extracts, focused on the fatty acids, triterpenoids, sterols, long chain aliphatic alcohols and tocopherols, was investigated by gas chromatography-mass spectrometry (GC-MS) analysis of the dichloromethane extracts. The lipophilic extractives of the ripe A. unedo berries ranged from 0.72% to 1.66% (w/w of dry weight), and consisted mainly of triterpenoids, fatty acids and sterols. Minor amounts of long chain aliphatic alcohols and tocopherols were also identified. Forty-one compounds were identified and among these, ursolic acid, lupeol, α-amyrin, linoleic and α-linolenic acids, and β-sitosterol were highlighted as the major components. To the best of our knowledge the current research study provides the most detailed phytochemical repository for the lipophilic composition of A. unedo, and offers valuable information for future valuation and exploitation of these berries.

  9. Bioactive Phytochemicals from Wild Arbutus unedo L. Berries from Different Locations in Portugal: Quantification of Lipophilic Components

    Directory of Open Access Journals (Sweden)

    Daniela F. S. Fonseca

    2015-06-01

    Full Text Available The lipophilic composition of wild Arbutus unedo L. berries, collected from six locations in Penacova (center of Portugal, as well as some general chemical parameters, namely total soluble solids, pH, titratable acidity, total phenolic content and antioxidant activity was studied in detail to better understand its potential as a source of bioactive compounds. The chemical composition of the lipophilic extracts, focused on the fatty acids, triterpenoids, sterols, long chain aliphatic alcohols and tocopherols, was investigated by gas chromatography–mass spectrometry (GC–MS analysis of the dichloromethane extracts. The lipophilic extractives of the ripe A. unedo berries ranged from 0.72% to 1.66% (w/w of dry weight, and consisted mainly of triterpenoids, fatty acids and sterols. Minor amounts of long chain aliphatic alcohols and tocopherols were also identified. Forty-one compounds were identified and among these, ursolic acid, lupeol, α-amyrin, linoleic and α-linolenic acids, and β-sitosterol were highlighted as the major components. To the best of our knowledge the current research study provides the most detailed phytochemical repository for the lipophilic composition of A. unedo, and offers valuable information for future valuation and exploitation of these berries.

  10. Crown Ether Complexes of Alkali-Metal Chlorides from SO2.

    Science.gov (United States)

    Reuter, Kirsten; Rudel, Stefan S; Buchner, Magnus R; Kraus, Florian; von Hänisch, Carsten

    2017-07-18

    The structures of alkali-metal chloride SO 2 solvates (Li-Cs) in conjunction with 12-crown-4 or 1,2-disila-12-crown-4 show strong discrepancies, despite the structural similarity of the ligands. Both types of crown ethers form 1:1 complexes with LiCl to give [Li(1,2-disila-12-crown-4)(SO 2 Cl)] (1) and [Li(12-crown-4)Cl]⋅4 SO 2 (2). However, 1,2-disila-12-crown-4 proved unable to coordinate cations too large for the cavity diameter, for example, by the formation of sandwich-type complexes. As a result, 12-crown-4 reacts exclusively with the heavier alkali-metal chlorides NaCl, KCl and RbCl. Compounds [Na(12-crown-4) 2 ]Cl⋅4 SO 2 (3) and [M(12-crown-4) 2 (SO 2 )]Cl⋅4 SO 2 (4: M=K; 5: M=Rb) all showed S-coordination to the chloride ions through four SO 2 molecules. Compounds 4 and 5 additionally exhibit the first crystallographically confirmed non-bridging O,O'-coordination mode of SO 2 . Unexpectedly, the disila-crown ether supports the dissolution of RbCl and CsCl in the solvent and gives the homoleptic SO 2 -solvated alkali-metal chlorides [MCl⋅3 SO 2 ] (6: M=Rb; 7: M=Cs), which incorporate bridging μ-O,O'-coordinating moieties and the unprecedented side-on O,O'-coordination mode. All compounds were characterised by single-crystal X-ray diffraction. The crown ether complexes were additionally studied by using NMR spectroscopy, and the presence of SO 2 at ambient temperature was revealed by IR spectroscopy of the neat compounds. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. 21 CFR 872.3770 - Temporary crown and bridge resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Temporary crown and bridge resin. 872.3770 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3770 Temporary crown and bridge resin. (a) Identification. A temporary crown and bridge resin is a device composed of a material, such as...

  12. Randomized, Controlled Clinical Trial of Bilayer Ceramic and Metal-Ceramic Crown Performance

    Science.gov (United States)

    Esquivel-Upshaw, Josephine; Rose, William; Oliveira, Erica; Yang, Mark; Clark, Arthur E.; Anusavice, Kenneth

    2013-01-01

    Purpose Analyzing the clinical performance of restorative materials is important, as there is an expectation that these materials and procedures will restore teeth and do no harm. The objective of this research study was to characterize the clinical performance of metal-ceramic crowns, core ceramic crowns, and core ceramic/veneer ceramic crowns based on 11 clinical criteria. Materials and Methods An IRB-approved, randomized, controlled clinical trial was conducted as a single-blind pilot study. The following three types of full crowns were fabricated: (1) metal-ceramic crown (MC) made from a Pd-Au-Ag-Sn-In alloy (Argedent 62) and a glass-ceramic veneer (IPS d.SIGN veneer); (2) non-veneered (glazed) lithium disilicate glass-ceramic crown (LDC) (IPS e.max Press core and e.max Ceram Glaze); and (3) veneered lithia disilicate glass-ceramic crown (LDC/V) with glass-ceramic veneer (IPS Empress 2 core and IPS Eris). Single-unit crowns were randomly assigned. Patients were recalled for each of 3 years and were evaluated by two calibrated clinicians. Thirty-six crowns were placed in 31 patients. A total of 12 crowns of each of the three crown types were studied. Eleven criteria were evaluated: tissue health, marginal integrity, secondary caries, proximal contact, anatomic contour, occlusion, surface texture, cracks/chips (fractures), color match, tooth sensitivity, and wear (of crowns and opposing enamel). Numerical rankings ranged from 1 to 4, with 4 being excellent, and 1 indicating a need for immediate replacement. Statistical analysis of the numerical rankings was performed using a Fisher’s exact test. Results There was no statistically significant difference between performance of the core ceramic crowns and the two veneered crowns at year 1 and year 2 (p > 0.05). All crowns were rated either as excellent or good for each of the clinical criteria; however, between years 2 and 3, gradual roughening of the occlusal surface occurred in some of the ceramic-ceramic crowns

  13. The analysis of lipophilic marine toxins : development of an alternative method

    NARCIS (Netherlands)

    Gerssen, A.

    2010-01-01

    Lipophilic marine toxins are produced by certain algae species and can accumulate in filter feeding shellfish such as mussels, scallops and oysters. Consumption of contaminated shellfish can lead to severe intoxications such as diarrhea, abdominal cramps and vomiting. Methods described in

  14. Enhancing mechanism of intestinal absorption of highly lipophilic compounds using microemulsion – Quantitative analysis of the partitioning to the mesenteric lymph in intestinal cells

    Directory of Open Access Journals (Sweden)

    Kazunori Iwanaga

    2015-06-01

    Full Text Available The purpose of this study was to quantify the effect of the fatty acid alkyl-chain length of a polyethylene glycol (PEG glyceryl ester, which was used as a microemulsion oil component, on the partitioning of highly lipophilic compounds to the mesenteric lymph after oral administration. Oil blue N, a highly lipophilic anthraquinone derivative, was orally administered to lymph duct-cannulated and untreated rats in two kinds of different microemulsions. Gelucire® 50/13 and Gelucire® 44/14 were used as the oil component with long chain and medium chain fatty acid portions, respectively, of PEG glyceryl esters in microemulsions. The cumulative amount of oil blue N in lymph fluid was almost the same between the two microemulsions, although the transferred amount of oil component (triglyceride in the lymph after administration of the Gelucire® 50/13 microemulsion was significantly higher than that of the Gelucire® 44/14 microemulsion. On the other hand, the solubility of oil blue N in Gelucire® 44/14 was much higher than that in Gelucire® 50/13. No significant differences were observed between microemulsions in the bioavailability of oil blue N. From these data, the partitioning of oil blue N to the lymph was calculated using a mathematical model, showing that the partitioning ratios of oil blue N to the lymph fluid were almost the same for both microemulsions. The solubility of oil blue N to the oil component of the microemulsions and the transfer of triglycerides to the lymph after administration of the microemulsions counteract each other, leading to similar partitioning ratios of oil blue N to the lymph.

  15. Reduction in lipophilicity improved the solubility, plasma–protein binding, and permeability of tertiary sulfonamide RORc inverse agonists

    Energy Technology Data Exchange (ETDEWEB)

    Fauber, Benjamin P.; René, Olivier; de Leon Boenig, Gladys; Burton, Brenda; Deng, Yuzhong; Eidenschenk, Céline; Everett, Christine; Gobbi, Alberto; Hymowitz, Sarah G.; Johnson, Adam R.; La, Hank; Liimatta, Marya; Lockey, Peter; Norman, Maxine; Ouyang, Wenjun; Wang, Weiru; Wong, Harvey (Genentech); (Argenta)

    2014-08-01

    Using structure-based drug design principles, we identified opportunities to reduce the lipophilicity of our tertiary sulfonamide RORc inverse agonists. The new analogs possessed improved RORc cellular potencies with >77-fold selectivity for RORc over other nuclear receptors in our cell assay suite. The reduction in lipophilicity also led to an increased plasma–protein unbound fraction and improvements in cellular permeability and aqueous solubility.

  16. Bromine-rich Zinc Bromides: Zn6Br12(18-crown-6)2×(Br2)5, Zn4Br8(18-crown-6)2×(Br2)3, and Zn6Br12(18-crown-6)2×(Br2)2.

    Science.gov (United States)

    Hausmann, David; Feldmann, Claus

    2016-06-20

    The bromine-rich zinc bromides Zn6Br12(18-crown-6)2×(Br2)5 (1), Zn4Br8(18-crown-6)2×(Br2)3 (2), and Zn6Br12(18-crown-6)2×(Br2)2 (3) are prepared by reaction of ZnBr2, 18-crown-6, and elemental bromine in the ionic liquid [MeBu3N][N(Tf)2] (N(Tf)2 = bis(trifluoromethylsulfonyl)amide). Zn6Br12(18-crown-6)2×(Br2)5 (1) is formed instantaneously by the reaction. Even at room temperature, compound 1 releases bromine, which was confirmed by thermogravimetry (TG) and mass spectrometry (MS). The release of Br2 can also be directly followed by the color and density of the title compounds. With controlled conditions (2 weeks, 25 °C, absence of excess Br2) Zn6Br12(18-crown-6)2×(Br2)5 (1) slowly releases bromine with conconcurrent generation of Zn4Br8(18-crown-6)2×(Br2)3 (2) (in ionic liquid) and Zn6Br12(18-crown-6)2×(Br2)2 (3) (in inert oil). All bromine-rich zinc bromides contain voluminous uncharged (e.g., Zn3Br6(18-crown-6), Zn2Br4(18-crown-6)) or ionic (e.g., [Zn2Br3(18-crown-6)](+), [(Zn2Br6)×(Br2)2](2-)) building units with dibromine molecules between the Zn oligomers and partially interconnecting the Zn-containing building units. Due to the structural similarity, the bromine release is possible via crystal-to-crystal transformation with retention of the crystal shape.

  17. Wind Tunnel Experiments to Study Chaparral Crown Fires.

    Science.gov (United States)

    Cobian-Iñiguez, Jeanette; Aminfar, AmirHessam; Chong, Joey; Burke, Gloria; Zuniga, Albertina; Weise, David R; Princevac, Marko

    2017-11-14

    The present protocol presents a laboratory technique designed to study chaparral crown fire ignition and spread. Experiments were conducted in a low velocity fire wind tunnel where two distinct layers of fuel were constructed to represent surface and crown fuels in chaparral. Chamise, a common chaparral shrub, comprised the live crown layer. The dead fuel surface layer was constructed with excelsior (shredded wood). We developed a methodology to measure mass loss, temperature, and flame height for both fuel layers. Thermocouples placed in each layer estimated temperature. A video camera captured the visible flame. Post-processing of digital imagery yielded flame characteristics including height and flame tilt. A custom crown mass loss instrument developed in-house measured the evolution of the mass of the crown layer during the burn. Mass loss and temperature trends obtained using the technique matched theory and other empirical studies. In this study, we present detailed experimental procedures and information about the instrumentation used. The representative results for the fuel mass loss rate and temperature filed within the fuel bed are also included and discussed.

  18. Alkali-crown ether complexes at metal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Thontasen, Nicha; Deng, Zhitao; Rauschenbach, Stephan [Max Planck Institute for Solid State Research, Stuttgart (Germany); Levita, Giacomo [University of Trieste, Trieste (Italy); Malinowski, Nikola [Max Planck Institute for Solid State Research, Stuttgart (Germany); Bulgarian Academy of Sciences, Sofia (Bulgaria); Kern, Klaus [Max Planck Institute for Solid State Research, Stuttgart (Germany); EPFL, Lausanne (Switzerland)

    2010-07-01

    Crown ethers are polycyclic ethers which, in solution, selectively bind cations depending on the size of the ring cavity. The study of a single host-guest complex is highly desirable in order to reveal the characteristics of these specific interactions at the atomic scale. Such detailed investigation is possible at the surface where high resolution imaging tools like scanning tunneling microscopy (STM) can be applied. Here, electrospray ion beam deposition (ES-IBD) is employed for the deposition of Dibenzo-24-crown-8 (DB24C8)-H{sup +}, -Na{sup +} and -Cs{sup +} complexes on a solid surface in ultrahigh vacuum (UHV). Where other deposition techniques have not been successful, this deposition technique combines the advantages of solution based preparation of the complex ions with a highly clean and controlled deposition in UHV. Single molecular structures and the cation-binding of DB24C8 at the surface are studied in situ by STM and MALDI-MS (matrix assisted laser desorption ionization mass spectrometry). The internal structure of the complex, i.e. ring and cavity, is observable only when alkali cations are incorporated. The BD24C8-H{sup +} complex in contrast appears as a compact feature. This result is in good agreement with theoretical models based on density functional theory calculations.

  19. Active site-directed alkylation of Na+-K+-ATPase by digitalis sulphonate derivatives of different lipophilicity.

    Science.gov (United States)

    Fricke, U.; Klaus, W.; Rogatti, M.

    1981-01-01

    1 Sulphonate derivatives of k-strophanthidin and digitoxigenin were tested as active site-directed labels of Na+-K+-adenosine triphosphatase (Na+-ATPase) from guinea-pig heart. 2 Lipophilicity ranged between P = 93 for strophanthidin-3-tosyloxy-acetate (STA) and P = 3028 for digitoxigenin-3-tosyloxy-acetate (DTA). 3 Although the alkylating moiety of STA and DTA was identical, the reversibility of Na+-K+-ATPase inhibition varied appreciably (82% and 35% respectively). 4 It is concluded that lipophilicity contributes considerably to the irreversible binding of alkylating cardiotonic steroids to myocardial Na+-K+-ATPase. PMID:6261865

  20. Descriptive statistics of tree crown condition in the North Central United States

    Science.gov (United States)

    KaDonna C. Randolph; Randall S. Morin; Jim Steinman

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Illinois, Indiana, Michigan, Minnesota, Missouri, and Wisconsin...

  1. Functional characteristics of a renal H+/lipophilic cation antiport system in porcine LLC-PK1 cells and rats.

    Science.gov (United States)

    Matsui, Ryutaro; Hattori, Ryutaro; Usami, Youhei; Koyama, Masumi; Hirayama, Yuki; Matsuba, Emi; Hashimoto, Yukiya

    2018-02-01

    We have recently found an H + /quinidine (a lipophilic cation, QND) antiport system in Madin-Darby canine kidney (MDCK) cells. The primary aim of the present study was to evaluate whether the H + /lipophilic cation antiport system is expressed in porcine LLC-PK 1 cells. That is, we investigated uptake and/or efflux of QND and another cation, bisoprolol, in LLC-PK 1 cells. In addition, we studied the renal clearance of bisoprolol in rats. Uptake of QND into LLC-PK 1 cells was decreased by acidification of the extracellular pH or alkalization of the intracellular pH. Cellular uptake of QND from the apical side was much greater than from the basolateral side. In addition, apical efflux of QND from LLC-PK 1 cells was increased by acidification of the extracellular pH. Furthermore, lipophilic cationic drugs significantly reduced uptake of bisoprolol in LLC-PK 1 cells. Renal clearance of bisoprolol in rats was approximately 7-fold higher than that of creatinine, and was markedly decreased by alkalization of the urine pH. The present study suggests that the H + /lipophilic cation antiport system is expressed in the apical membrane of LLC-PK 1 cells. Moreover, the H + /lipophilic cation antiport system may be responsible for renal tubular secretion of bisoprolol in rats. Copyright © 2017 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.

  2. Etiology and Population Genetics of Colletotrichum spp. Causing Crown and Fruit Rot of Strawberry.

    Science.gov (United States)

    Ureña-Padilla, A R; Mackenzie, S J; Bowen, B W; Legard, D E

    2002-11-01

    ABSTRACT Isolates of Colletotrichum spp. from diseased strawberry fruit and crowns were evaluated to determine their genetic diversity and the etiology of the diseases. Isolates were identified to species using polymerase chain reaction primers for a ribosomal internal transcribed spacer region and their pathogenicity was evaluated in bioassays. Isolates were scored for variation at 40 putative genetic loci with random amplified polymorphic DNA and microsatellite markers. Only C. acutatum was recovered from diseased fruit. Nearly all isolates from crowns were C. gloeosporioides. In crown bioassays, only isolates of C. gloeosporioides from strawberry caused collapse and death of plants. A dendrogram generated from the genetic analysis identified several primary lineages. One lineage included isolates of C. acutatum from fruit and was characterized by low diversity. Another lineage included isolates of C. gloeosporioides from crowns and was highly polymorphic. The isolates from strawberry formed distinctive clusters separate from citrus isolates. Evaluation of linkage disequilibrium among polymorphic loci in isolates of C. gloeosporioides from crowns revealed a low level of disequilibrium as would be expected in sexually recombining populations. These results suggest that epidemics of crown rot are caused by Glomerella cingulata (anamorph C. gloeosporioides) and that epidemics of fruit rot are caused by C. acutatum.

  3. Changes of mercury contamination in red-crowned cranes, Grus japonensis, in East Hokkaido, Japan.

    Science.gov (United States)

    Teraoka, Hiroki; Tagami, Yukari; Kudo, Moe; Miura, Yoshiaki; Okamoto, Erika; Matsumoto, Fumio; Koga, Kimiya; Uebayashi, Akiko; Shimura, Ryoji; Inoue, Masako; Momose, Kunikazu; Masatomi, Hiroyuki; Kitazawa, Takio; Hiraga, Takeo; Subramanian, Annamalai

    2012-07-01

    Red-crowned cranes (Grus japonensis) are native to eastern Hokkaido (island population), in contrast to the mainland, which migrates between the Amur River basin and eastern China-Korea peninsula. During the 1990s we found that Red-crowned cranes in Hokkaido were highly contaminated with mercury: however, the source was unknown. We investigated the time trend of mercury contamination in Red-crowned cranes. Total mercury levels in the livers and kidneys from cranes dead in the 2000s were lower than those dead in the 1990s. Feather is a major pathway of mercury excretion for many bird species and is used as an indicator of blood mercury level during feather growth. As internal organs from the specimens collected before 1988 were not available, we analyzed the flight feather shavings from stuffed Red-crowned cranes dead in 1959-1987 and found that the mercury level of feathers from cranes dead in the 1960s and 1970s was not more than those from the cranes dead in the 2000s. These results suggest that mercury contamination in Red-crowned cranes in Hokkaido decreased temporally during the 1990s-2000s. This indicates the possible occurrence of some mercury pollution in Red-crowned cranes' habitat in this region in the 1990s or before.

  4. Descriptive statistics of tree crown condition in the United States Interior West

    Science.gov (United States)

    KaDonna C. Randolph; Mike T. Thompson

    2010-01-01

    The U.S. Forest Service Forest Inventory and Analysis (FIA) Program uses visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes four crown condition indicators (crown dieback, crown density, foliage transparency, and sapling crown vigor) measured in Colorado, Idaho, Nevada, Utah, and Wyoming between 1996 and...

  5. Application of GC-MS for the detection of lipophilic compounds in diverse plant tissues

    Directory of Open Access Journals (Sweden)

    Hellmann Hanjo

    2009-04-01

    Full Text Available Abstract Background The concept of metabolite profiling has been around for decades and technical innovations are now enabling it to be carried out on a large scale with respect to the number of both metabolites measured and experiments carried out. However, studies are generally confined to polar compounds alone. Here we describe a simple method for lipophilic compounds analysis in various plant tissues. Results We choose the same preparative and instrumental platform for lipophilic profiling as that we routinely use for polar metabolites measurements. The method was validated in terms of linearity, carryover, reproducibility and recovery rates, as well as using various plant tissues. As a first case study we present metabolic profiling of Arabidopsis root and shoot tissue of wild type (C24 and mutant (rsr4-1 plants deficient on vitamin B6. We found significant alterations in lipid constituent contents, especially in the roots, which were characterised by dramatic increases in several fatty acids, thus providing further hint for the role of pyridoxine in oxidative stress and lipid peroxidation. The second example is the lipophilic profiling of red and green tomato fruit cuticles of wild type (Alisa Craig and the DFD (delayed fruit deterioration mutant, which we compared and contrasted with the more focused wax analysis of these plants reported before. Conclusion We can rapidly and reliably detect and quantify over 40 lipophilic metabolites including fatty acids, fatty alcohols, alkanes, sterols and tocopherols. The method presented here affords a simple and rapid, yet robust complement to previously validated methods of polar metabolite profiling by gas-chromatography mass-spectrometry.

  6. Crowns and Crypts

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 6. Crowns and Crypts - A Fascinating Group of Multidentate Macrocyclic Ligands. Debasis Bandyopadhyay. General Article Volume 6 Issue 6 June 2001 pp 71-79. Fulltext. Click here to view fulltext PDF. Permanent link:

  7. In vitro fracture resistance of three commercially available zirconia crowns for primary molars.

    Science.gov (United States)

    Townsend, Janice A; Knoell, Patrick; Yu, Qingzhao; Zhang, Jian-Feng; Wang, Yapin; Zhu, Han; Beattie, Sean; Xu, Xiaoming

    2014-01-01

    The purpose of this study was to measure the fracture resistance of primary mandibular first molar zirconia crowns from three different manufacturers-EZ Pedo (EZP), NuSmile (NSZ), and Kinder Krowns (KK)-and compare it with the thickness of the zirconia crowns and the measured fracture resistance of preveneered stainless steel crowns (SSCs). The thickness of 20 zirconia crowns from three manufacturers were measured. The mean force required to fracture the crowns was determined. Preveneered NuSmile (NSW) SSCs were tested as a control. EZP crowns were significantly thicker in three of the six measured locations. The force required to fracture the EZP crown was significantly higher than that required for NSZ and KK. There was a positive correlation between fracture resistance and crown thickness in the mesial, distal, mesioocclusal, and distoocclusal dimensions. None of the zirconia crowns proved to be as resistant to fracture as the preveneered SSCs. Statistically significant differences were found among the forces required to fracture zirconia crowns by three different manufacturers. The increase in force correlated with crown thickness. The forces required to fracture the preveneered stainless steel crowns were greater than the forces required to fracture all manufacturers' zirconia crowns.

  8. [Clinical application of IPS-empress 2 pressable all-ceramic crowns].

    Science.gov (United States)

    Wang, Ai-jun; He, Xiao-ming; Liu, Li-xia; Zhang, Chao-biao; Zhang, Min; Shen, Bei-yong

    2007-02-01

    To evaluate the clinical prosthetic effect of IPS-Empress 2 pressahie ceramic crowns. 198 teeth of 70 patients were restored with IPS-Empress 2 pressahie ceramic crowns. The patients were asked to return in one week and every half year. The clinical prosthetic effect was evaluated. Through follow-up of 3-38 months, the veneer porcelain crowns of 3 teeth were broken. 2 crowns fall off due to teeth fracture, gingivitis occurred in 2 teeth, pulpitis or periapical periodontitis occurred in 3 teeth. The shades of 3 crowns were darkening. The prosthetic effect of 185 teeth was satisfied. The rate of satisfaction was 93.4%. IPS-Empress 2 pressable all-ceramic crown has the advantages of aesthetic effect, good hiocompatihility and simple fabrication. But its strength is not enough for posterior teeth and it can not cover the deep color of non-vital teeth and metal materials.

  9. Prospective assessment of CAD/CAM zirconia abutment and lithium disilicate crown restorations: 2.4 year results.

    Science.gov (United States)

    Cooper, Lyndon F; Stanford, Clark; Feine, Jocelyne; McGuire, Michael

    2016-07-01

    Single-tooth implant restorations are commonly used to replace anterior maxillary teeth. The esthetic, functional, and biologic outcomes are, in part, a function of the abutment and crown. The purpose of this clinical study was to describe the implant, abutment, and crown survival and complication rates for CAD/CAM zirconia abutment and lithium disilicate crown restorations for single-tooth implants. As part of a broader prospective investigation that enrolled and treated 141 participants comparing tissue responses at the conical interface (CI; AstraTech OsseoSpeed), flat-to-flat interface (FI; NobelSpeedy), and platform-switch interface (PS; NanoTite Certain Prevail) of single-tooth implants, computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia abutments (ATLANTIS Abutment) and cemented lithium disilicate (e.max) crowns were used in the restoration of all implants. After 2.4 years in function (3 years after implant placement), the implant, abutment, and crown of 110 participants were evaluated. Technical and biologic complications were recorded. Demographic results were tabulated as percentages with mean values and standard deviations. Abutment survival was calculated with the Kaplan-Meier method. After 2.4 years, no abutments or crowns had been lost. Abutment complications (screw loosening, screw fracture, fracture) were absent for all 3 implant groups. Crown complications were limited to 2 crowns debonding and 1 with excess cement (2.5%). Five biological complications (4.0%) were recorded. The overall complication rate was 6.5%. CAD/CAM zirconia abutments restored with cemented lithium disilicate crowns demonstrated high survival on 3 different implant-abutment interface designs. No abutment or abutment screw fracture occurred. The technical complications observed after 2.4 years were minor and reversible. The use of CAD/CAM zirconia abutments with cemented lithium disilicate crowns is associated with high technical and biologic success at 2

  10. Calorimetric study of binding of some disaccharides with crown ethers

    Energy Technology Data Exchange (ETDEWEB)

    Davydova, Olga I.; Lebedeva, Nataliya Sh.; Parfenyuk, Elena V

    2004-11-01

    Isothermal titration calorimetry has been applied to the determination of the thermodynamic parameters of binding of {beta}-lactose, {alpha},{alpha}-trehalose and sucrose with 15-crown-5 and 18-crown-6 in water at 298.15 K. The formation of 1:1 molecular associates has been found for the systems studied except 18-crown-6 and {beta}-lactose. The associates are preferentially or completely entropy stabilized. The most stable associate is formed between {alpha},{alpha}-trehalose and 18-crown-6. The obtained values of thermodynamic parameters of binding are discussed from the point of view of solute-solvent interactions as well as conformational and structural peculiarities of the disaccharides (DS) and crown ethers (CE)

  11. Calorimetric study of binding of some disaccharides with crown ethers

    International Nuclear Information System (INIS)

    Davydova, Olga I.; Lebedeva, Nataliya Sh.; Parfenyuk, Elena V.

    2004-01-01

    Isothermal titration calorimetry has been applied to the determination of the thermodynamic parameters of binding of β-lactose, α,α-trehalose and sucrose with 15-crown-5 and 18-crown-6 in water at 298.15 K. The formation of 1:1 molecular associates has been found for the systems studied except 18-crown-6 and β-lactose. The associates are preferentially or completely entropy stabilized. The most stable associate is formed between α,α-trehalose and 18-crown-6. The obtained values of thermodynamic parameters of binding are discussed from the point of view of solute-solvent interactions as well as conformational and structural peculiarities of the disaccharides (DS) and crown ethers (CE)

  12. Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study.

    Science.gov (United States)

    Jeong, Ii-Do; Kim, Woong-Chul; Park, Jinyoung; Kim, Chong-Myeong; Kim, Ji-Hwan

    2017-08-01

    This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (α=.05). The RMS value of lithium disilicate crown was 29.2 (4.1) µm and 17.6 (5.5) µm on the outer and inner surfaces, respectively, whereas these values were 18.6 (2.0) µm and 20.6 (5.1) µm for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface ( P <.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

  13. [Fractographic analysis of clinically failed anterior all ceramic crowns].

    Science.gov (United States)

    DU, Qian; Zhou, Min-bo; Zhang, Xin-ping; Zhao, Ke

    2012-04-01

    To identify the site of crack initiation and propagation path of clinically failed all ceramic crowns by fractographic analysis. Three clinically failed anterior IPS Empress II crowns and two anterior In-Ceram alumina crowns were retrieved. Fracture surfaces were examined using both optical stereo and scanning electron microscopy. Fractographic theory and fracture mechanics principles were applied to disclose the damage characteristics and fracture mode. All the crowns failed by cohesive failure within the veneer on the labial surface. Critical crack originated at the incisal contact area and propagated gingivally. Porosity was found within the veneer because of slurry preparation and the sintering of veneer powder. Cohesive failure within the veneer is the main failure mode of all ceramic crown. Veneer becomes vulnerable when flaws are present. To reduce the chances of chipping, multi-point occlusal contacts are recommended, and layering and sintering technique of veneering layer should also be improved.

  14. The confusing array of tooth-colored crowns.

    Science.gov (United States)

    Christensen, Gordon J

    2003-09-01

    The venerable PFM crown or fixed prosthesis still dominates the tooth-colored restoration market. However, use of PFMs is declining slightly, as the many new all-ceramic and resin-based composite crowns and fixed-prosthesis products flood the market. Several situations may indicate the use of materials other than PFM. They include patients requiring a high level of esthetic acceptability, patients with proven or perceived allergies to the metals used in dentistry and bruxing or clenching patients with metal allergies or desire to eliminate metal from their mouths. PFM restorations have been proven during 40 years of successful use. They provide acceptable esthetics for most situations, minimal fracture during service, proven ability to serve in multiple-unit situations and excellent fit, and the profession has detailed knowledge of these restorations' advantages, disadvantages and physical characteristics. PFM restorations have only a few well-known negative characteristics. Be cautious as you elect to move from the reliability and positive history of PFM to relatively unknown types of restorations.

  15. Mesiodistal Crown Dimensions of Permanent Teeth in Bangladeshi Population

    Directory of Open Access Journals (Sweden)

    Saeed Hossain Khan

    2011-09-01

    Full Text Available Background: Variation in tooth size is influenced by genetic and environmental factors. Several studies have reported tooth size variation between and within different racial groups. In order to improve the quality of dental care available, there is a great need for data on the mesiodistal crown dimensions of the individual teeth of Bangladeshi population. Objectives: To find nominative data on the mesiodistal crown dimensions of permanent teeth in Bangladeshi population and to compare the findings with those reported in other populations. Methods: This observational study was done from January, 2008 to June, 2010 in the Department of Orthodontics, Faculty of Dentistry, Bangabandhu Sheikh Mujib Medical University. A total of 244 Bangladeshi subjects (77 males and 167 females, aged 7 – 36 years (mean 18.3 years with no age limit who attended at the above mentioned place for treatment were included in the study. Main outcome measure was mesiodistal crown dimension of each tooth class of permanent dentition. Mesiodistal crown dimensions were measured from dental casts of the permanent teeth. Results: Males had significantly larger teeth than females for maxillary central incisors (p < 0.05 and for the mandibular second premolars (p < 0.001. In both sexes, the maxillary lateral incisors showed the greatest variability [coefficient of variation (CV 10.7%] and the maxillary canines the least (CV 6.9% in mesiodistal crown dimension. Mandibular canines displayed greater sexual dimorphism in mesiodistal crown size than in any other tooth classes. Comparisons of the mesiodistal crown dimensions between population groups showed that Bangladeshis have tooth sizes close to those of North Indians, Icelanders and Jordanians but larger than those of North American Whites. Conclusions: From this study, a standard for the mesiodistal crown dimensions of permanent dentition of Bangladeshi males and females are obtained. Key Words: Crown dimension; Mesio

  16. In vitro evaluation of the marginal integrity of CAD/CAM interim crowns.

    Science.gov (United States)

    Kelvin Khng, Kwang Yong; Ettinger, Ronald L; Armstrong, Steven R; Lindquist, Terry; Gratton, David G; Qian, Fang

    2016-05-01

    The accuracy of interim crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems has not been well investigated. The purpose of this in vitro study was to evaluate the marginal integrity of interim crowns made by CAD/CAM compared with that of conventional polymethylmethacrylate (PMMA) crowns. A dentoform mandibular left second premolar was prepared for a ceramic crown and scanned for the fabrication of 60 stereolithical resin dies, half of which were scanned to fabricate 15 Telio CAD-CEREC and 15 Paradigm MZ100-E4D-E4D crowns. Fifteen Caulk and 15 Jet interim crowns were made on the remaining resin dies. All crowns were cemented with Tempgrip under a 17.8-N load, thermocycled for 1000 cycles, placed in 0.5% acid fuschin for 24 hours, and embedded in epoxy resin before sectioning from the mid-buccal to mid-lingual surface. The marginal discrepancy was measured using a traveling microscope, and dye penetration was measured as a percentage of the overall length under the crown. The mean vertical marginal discrepancy of the conventionally made interim crowns was greater than for the CAD/CAM crowns (P=.006), while no difference was found for the horizontal component (P=.276). The mean vertical marginal discrepancy at the facial surface of the Caulk crowns was significantly greater than that of the other 3 types of interim crowns (Pmargin, the mean horizontal component of the Telio crowns was significantly larger than that of the other 3 types, with no difference at the lingual margins (P=.150). The mean percentage dye penetration for the Paradigm MZ100-E4D crowns was significantly greater and for Jet crowns significantly smaller than for the other 3 crowns (Pmarginal discrepancies of the Jet interim crowns at the facial surface and with the horizontal marginal discrepancies of the Caulk interim crowns at the lingual surface (Pmarginal discrepancy was found with the interim crowns fabricated by CAD/CAM as compared with PMMA crowns

  17. Effects of Heterogeneity within Tree Crowns on Airborne-Quantified SIF and the CWSI as Indicators of Water Stress in the Context of Precision Agriculture

    Directory of Open Access Journals (Sweden)

    Carlos Camino

    2018-04-01

    Full Text Available This research focused on understanding the effects of structural heterogeneity within tree crowns on the airborne retrieval of solar-induced chlorophyll fluorescence (SIF and the Crop Water Stress Index (CWSI. We explored the SIF and CWSI variability observed within crowns of trees subjected to different water stress regimes and its effect on the relationships with leaf physiological measurements. High-resolution (20 cm hyperspectral imagery was acquired to assess fluorescence retrieval from sunlit portions of the tree crowns using the Fraunhofer line depth method, and from entire crowns using automatic object-based tree crown detection methods. We also measured the canopy temperature distribution within tree crowns using segmentation algorithms based on temperature percentiles applied to high-resolution (25 cm thermal imagery. The study was conducted in an almond orchard cultivated under three watering regimes in Cordoba, in southern Spain. Three airborne campaigns took place during the summer of 2015 using high-resolution hyperspectral and thermal cameras on board a manned aircraft. Relationships between SIF and the assimilation rate improved significantly when the sunlit tree crown pixels extracted through segmentation were used for all flight dates. By contrast, the SIF signal extracted from the entire tree crowns was highly degraded due to the canopy heterogeneity observed within tree crowns. The quartile crown segmentations applied to the thermal images showed that the CWSI values obtained were within the theoretically expected CWSI range only when the pixels were extracted from the 50th percentile class. However, the CWSI values were biased in the upper quartile (Q75 for all watering regimes due to the soil background effects on the calculated mean crown temperature. The relationship between the CWSI and Gs was heavily affected by the crown segmentation levels applied and improved remarkably when the CWSI values were calculated from the

  18. Crown ether derivatives of EDTA: Pt. 6

    International Nuclear Information System (INIS)

    Liu Zhongqun; Qin Shengying; Chen Shaojin; Tan Lin

    1988-01-01

    EDTA-diaminodibenzo-18-crown-6 (cis- and trans-) condensation polymer is a new compound of crown ether derivatives of EDTA. In this paper the adsorption behaviors of U(IV) and U(VI) on this polymer from chloride solutions and effects of hydrochloric acid concentrations, salting-out agents and organic solvents on distribution coefficient (K d ) of uranium are investigated. Adsorption mechanism of uranyl ion (UO 2 2+ ) on this polymer was studied with IR spectra and by means of the adsorption behaviors of compounds of similar structure. Experimental results show that both polyether section and carboxyl groups in EDTA-diaminodibenzo-18-crown-6 take part in complexation with uranyl ion and synergistic effect appeared

  19. Switchable Diastereoselectivity in the Fluoride Promoted Vinylogous Mukaiyama-Michael Reaction of 2-Trimethylsilyloxyfuran Catalyzed by Crown Ethers

    KAUST Repository

    Della Sala, Giorgio

    2017-05-31

    The fluoride promoted vinylogous Mukaiyama-Michael reaction (VMMR) of 2-trimethylsilyloxyfuran with diverse α,β-unsaturated ketones is described. The TBAF catalyzed VMMR afforded high anti-diastereoselectivity irrespective of the solvents used. The KF/crown ethers catalytic systems proved to be highly efficient in terms of yields and resulted in a highly diastereoselective unprecedented solvent/catalyst switchable reaction. Anti-adducts were obtained as single diastereomers or with excellent diastereoselectivities when benzo-15-crown-5 in CH2Cl2 was employed. On the other hand, high syn-diastereoselectivities (from 76:24 to 96:4) were achieved by employing dicyclohexane-18-crown-6 in toluene. Based on DFT calculations, the catalysts/solvents-dependent switchable diastereoselectivities are proposed to be the result of loose or tight cation-dienolate ion pairs.

  20. Antitumoral and antioxidant activities of lipophilic and phenolic extracts from Cynara cardunculus L. var. altilis (DC)

    OpenAIRE

    Ramos, P.; Guerra, A.; Guerreiro, O.; Santos, S.; Oliveira, H.; Freire, C.; Rocha, S.; Silvestre, A.; Duarte, M. F.

    2014-01-01

    Cynara cardunculus L. var. altilis (DC) (Cca) grows under the semi-arid conditions as those of south of Portugal. Given to high cellulose and hemicelluloses contents, paper pulp production has been proposed [1]. Moreover, the extraction of bioactive compounds could also be considered for an integrated valorization of Cca. Sesquiterpene lactones (SL) and pentacyclic triterpenes, the major constituents of Cca leaves and capitula lipophilic fractions [2] showed lower tryglyceride levels in rat s...

  1. On the Solubility and Lipophilicity of Metallacarborane Pharmacophores

    Czech Academy of Sciences Publication Activity Database

    Rak, J.; Dejlová, B.; Lampová, H.; Kaplánek, R.; Matějíček, P.; Cígler, Petr; Král, V.

    2013-01-01

    Roč. 10, č. 5 (2013), s. 1751-1759 ISSN 1543-8384 R&D Projects: GA MŠk(CZ) LH11027; GA TA ČR(CZ) TE01020028; GA AV ČR IAAX00320901 Grant - others:GA ČR(CZ) GAP303/11/1291; Biomedreg Project(XE) CZ.1.05/2.1.00/01.0030 Program:GA Institutional support: RVO:61388963 Keywords : metallacarborane * cobalt bis(dicarbollide) * serum albumin * HIV protease * inhibitor * lipophilicity * P-ow * solubility Subject RIV: CC - Organic Chemistry Impact factor: 4.787, year: 2013

  2. Optical effects of different colors of artificial gingiva on ceramic crowns.

    Science.gov (United States)

    Wang, Jian; Lin, Jin; Gil, Mindy; Da Silva, John D; Wright, Robert; Ishikawa-Nagai, Shigemi

    2013-08-01

    The interaction between gingival color and the shade of ceramic restorations has never been fully studied. The purpose of this study is to investigate the optical effects of altering artificial gingival color on the ceramic crown shade in the cervical area. Thirty-one all-ceramic crowns of different shades were used in this study with six different artificial gingival colors. Using a spectrophotometer (Crystaleye(®) Olympus, Japan), we measured the shade of crowns in cervical areas with each of six different artificial gingiva. The crown color measured in the presence of pink artificial gingiva (control) was compared with the crown color with five other artificial gingiva. color difference values ΔE* were calculated and compared between the control group and test groups and the correlation of the artificial gingival color with the crown color was also assessed. Significant differences were found in the mean L* and a* values of all-ceramic crowns at the cervical regions in all six gingival color groups (pcolors of artificial gingiva generated clinically detectable shade differences in the cervical region of ceramic crowns. Copyright © 2013. Published by Elsevier Ltd.

  3. Clinical Performance of Pedo Jacket Crowns in Maxillary Anterior Primary Teeth.

    Science.gov (United States)

    Castro, Aimee; Badr, Sherine B Y; El-Badrawy, Wafa; Kulkarni, Gajanan

    2016-09-15

    To assess the clinical performance of Pedo Jacket crowns for restoration of carious primary anterior teeth. A total of 129 carious primary incisors and canines of 48 children younger than 71 months of age- were restored with Pedo Jacket crowns and resin-modified glass ionomer cementation. They were assessed for: ease of use; presence of recurrent decay; wear; partial or complete loss of the crown; color stability; gingival health; and overall clinical success over a 12-month follow-up. The patient's behavior at the restorative appointment during crown placement was also assessed. An overall clinical success of 89.5 percent of the teeth in 87.3 percent of the children was seen one year later. The crowns were easy to use, even in uncooperative children. The color stability, wear, plaque accumulation, and gingival health were acceptable. Discoloration, wear, or complete loss of the crown were found in 13.1 percent, 5.4 percent, and 7.6 percent of children, respectively. Although not statistically significant, failures were associated with poor patient cooperation at the time of crown placement, poor oral hygiene, or operator error. Pedo Jacket crowns are a viable treatment alternative for carious maxillary primary anterior teeth.

  4. Switchable Diastereoselectivity in the Fluoride Promoted Vinylogous Mukaiyama-Michael Reaction of 2-Trimethylsilyloxyfuran Catalyzed by Crown Ethers

    KAUST Repository

    Della Sala, Giorgio; Sicignano, Marina; Schettini, Rosaria; De Riccardis, Francesco; Cavallo, Luigi; Minenkov, Yury; Batisse, Chloé ; Hanquet, Gilles; Leroux, Frederic; IZZO, Irene

    2017-01-01

    diastereoselectivities when benzo-15-crown-5 in CH2Cl2 was employed. On the other hand, high syn-diastereoselectivities (from 76:24 to 96:4) were achieved by employing dicyclohexane-18-crown-6 in toluene. Based on DFT calculations, the catalysts

  5. FEM and Von Mises Analysis on Prosthetic Crowns Structural Elements: Evaluation of Different Applied Materials.

    Science.gov (United States)

    Bramanti, Ennio; Cervino, Gabriele; Lauritano, Floriana; Fiorillo, Luca; D'Amico, Cesare; Sambataro, Sergio; Denaro, Deborah; Famà, Fausto; Ierardo, Gaetano; Polimeni, Antonella; Cicciù, Marco

    2017-01-01

    The aim of this paper is to underline the mechanical properties of dental single crown prosthodontics materials in order to differentiate the possibility of using each material for typical clinical condition and masticatory load. Objective of the investigation is to highlight the stress distribution over different common dental crowns by using computer-aided design software and a three-dimensional virtual model. By using engineering systems of analyses like FEM and Von Mises investigations it has been highlighted the strength over simulated lower first premolar crowns made by chrome cobalt alloy, golden alloy, dental resin, and zirconia. The prosthodontics crown models have been created and put on simulated chewing stresses. The three-dimensional models were subjected to axial and oblique forces and both guaranteed expected results over simulated masticatory cycle. Dental resin presented the low value of fracture while high values have been recorded for the metal alloy and zirconia. Clinicians should choose the better prosthetic solution for the teeth they want to restore and replace. Both prosthetic dental crowns offer long-term success if applied following the manufacture guide limitations and suggestions.

  6. Provisional crown failures in dental school predoctoral clinics.

    Science.gov (United States)

    Hyde, Jeffrey D; Bader, James A; Shugars, Daniel A

    2007-11-01

    Following a preliminary study indicating that at least 10 percent of single-unit crown temporary restorations failed in patients who received treatment by predoctoral students, a comprehensive examination of provisional crown failure was initiated to identify strategies to reduce the failure rate. For all provisionalized, natural tooth, single-unit crown preparations in University of North Carolina School of Dentistry predoctoral clinics for one year (N=1008), we noted tooth type, type of crown, student level, faculty coverage experience, treatment clinic, temporary material and luting agent, and retreatment (failure) of the provisional restoration. For failures, we also noted the stage of crown preparation at failure and the time since initial placement of the temporary. We analyzed these data using simple cross-tabs and logistic regression on need for retreatment (alpha =0.05). The failure rate was 18.75 percent (N=189). The median time to failure was twelve days; the 25(th) and 75(th) percentiles were six and twenty-six days. Significant risk factors, in order of odds ratio estimates, were molar tooth, second- or third-year student, and inexperienced faculty. Most provisional failures occurred during the final preparation phase of treatment. Provisional restoration failure is more frequent than was initially suspected from preliminary studies. Strategies for institutional intervention to reduce provisional restoration failure include greater attention to evaluating provisional crowns placed by inexperienced students (sophomores and juniors) and placing more emphasis on the retentiveness of provisional restorations reused following the final impression. Review of provisional evaluation procedures is also indicated for faculty who do not routinely supervise these procedures.

  7. 4-Bromoanilinium perchlorate 18-crown-6 clathrate

    Directory of Open Access Journals (Sweden)

    Min Guo

    2010-11-01

    Full Text Available The reaction of 4-bromoaniline, 18-crown-6, and perchloric acid in methanol yields the title compound, C6H7BrN+·ClO4−·C12H24O6, in which the protonated –NH3+ group forms three bifurcated N—H...O hydrogen bonds to the O atoms of the crown ether.

  8. Identification, introgression, and molecular marker genetic analysis and selection of a highly effective novel oat crown rust resistance from diploid oat, Avena strigosa

    Science.gov (United States)

    A new highly effective resistance to oat crown rust (Puccinia coronata f. sp. avenae) was identified in the diploid oat Avena strigosa PI 258731 and introgressed into hexaploid cultivated oat. Young plants with this resistance show moderate susceptibility, whereas older plant tissues and adult plant...

  9. Consequences of crown shortening canine teeth in Greenland sled dogs

    DEFF Research Database (Denmark)

    Kortegaard, H E; Anthony Knudsen, T; Dahl, S

    2015-01-01

    OBJECTIVES: To evaluate the consequences of crown shortening, focusing on the prevalence of pulp exposure and periapical pathology in Greenland sled dogs that had had their canine crowns shortened at an early age. METHODS: Five cadaver heads and 54 sled dogs underwent an oral examination for dental...... fractures and pulp exposure of canines. All canines were radiographed and evaluated for periapical pathology. RESULTS: The prevalence of canine pulp exposure in 12 (5 heads and 7 dogs) crown shortened dogs was 91 · 7%, and 21 · 3% in 47 not-crown shortened dogs. A significant (P pulp...... exposure of the canines in the crown shortened group compared to the not-crown shortened group was seen with a relative risk of 4 · 3 on a dog basis and a relative risk of 12 · 2 on a tooth basis. In dogs with pulp exposure of canines (n = 51) the prevalence of periapical pathology was 82 · 4%, but only 0...

  10. Direct chromatographic analysis of metabolites of lipophilic tracers in whole blood by ISRP chromatography

    International Nuclear Information System (INIS)

    Rosenspire, K.C.; Hirth, W.; Jurisson, S.; Nowotnik, D.P.; Eckelman, W.C.; Nunn, A.D.

    1991-01-01

    HPLC using columns packed with 5 μ Internal Surface Reverse Phase (ISRP) resin have shown utility in the analysis of lipophilic drugs and their metabolites by direct injection of serum or plasma samples. We have developed a method for rapid on-line separation of small hydrophobic components from cellular whole blood components. This is achieved through the use of 75 μ GFF (glycine-phenylalanine-phenylalanine) glass bead ISRP chromatographic material packed into a small HPLC column, and used in conjunction with an HPLC system containing a switching valve and a second analytical column. When heparinized whole blood is applied to a 75 μ GFF ISRP column, and the column eluted with an isotonic eluent, lipophilic compounds free in plasma are retained by the column, while plasma proteins, blood cells, and compounds bound to these blood components pass through the ISRP column. Following the elution of these components, the lipophilic compounds retained on the ISRP column are eluted by increasing the percentage of organic solvent in the eluent, and are further resolved (if required) by the analytical column. We have applied this analytical method to the study of metabolism of the 99m Tc-BATO (Boronic acid Adducts of Technetium diOxime) cerebral and myocardial perfusion tracers. (author)

  11. Crown and crown-root fractures: an evaluation of the treatment plans for management proposed by 154 specialists in restorative dentistry.

    Science.gov (United States)

    de Castro, Mara Antonio Monteiro; Poi, Wilson Roberto; de Castro, José Carlos Monteiro; Panzarini, Sônia Regina; Sonoda, Celso Koogi; Trevisan, Carolina Lunardelli; Luvizuto, Eloá Rodrigues

    2010-06-01

    Traumatic tooth injuries involve function and aesthetics and cause damage that range from minimal enamel loss to complex fractures involving the pulp tissue and even loss of the tooth crown. Technical knowledge and clinical experience are essential to establish an accurate diagnosis and provide a rational treatment. The purpose of this study was to evaluate the knowledge of Restorative Dentistry specialists about the management of crown and crown-root fractures based on treatment plans proposed by these professionals for these cases. A descriptive questionnaire was mailed to 245 Restorative Dentistry specialists with questions referring to their professional profile and the treatment plans they would propose for the management of crown and crow-root fractures resulting from dental trauma. One hundred and fifty-four questionnaires were returned properly filled. The data were subjected to descriptive statistics and the chi-square test was used to determine the frequency and the level of the significance among the variables. The analysis of data showed that in spite of having a specialist title, all interviewees had great difficulty in planning the treatments. As much as 42.8% of the participants were unable to treat all types of dental trauma. Complicated and uncomplicated crown-root fractures posed the greatest difficulties for the dentists to establish adequate treatment plans because these fractures require multidisciplinary knowledge and approach for a correct case planning and prognosis.

  12. Periodontal response to all-ceramic crowns (IPS Empress) in general practice.

    Science.gov (United States)

    Al-Wahadni, A M; Mansour, Y; Khader, Y

    2006-02-01

    The purpose of this study was to investigate the periodontal response to the presence of all-ceramic crowns (IPS Empress) in general practice patients. The convenience sample included 82 IPS Empress crowns placed in 64 patients. These crowns had been in place for an average of 16.27 (SD 9.26) months and ranged from 6.2 to 48.87 months at the time of clinical examination. Periodontal health status (as determined by dental plaque, gingival health status, periodontal pockets) was assessed around all crowned teeth and around matched contralateral teeth by one calibrated examiner. Periodontal indices utilized included the Plaque Index (PI), Gingival Index (GI) and pocket depth (PD) with calibrated probes graduated in millimetres. Plaque, gingival and PD values for crowned teeth were compared with those for control teeth using Wilcoxon signed-rank test for each clinical parameters. Chi-square was used to test the significance of the difference in their distribution between crowns and control teeth. Statistically, PI (0.35), GI (0.41) and mean PD scores (1.42) of IPS Empress crowned teeth compared less favourably with scores of the control teeth (0.27, 0.23 and 0.86 respectively). Teeth with IPS Empress crowns had poorer periodontal health and more clinically evident plaque than uncrowned teeth.

  13. Human Intestinal Fluid Layer Separation: The Effect On Colloidal Structures & Solubility Of Lipophilic Compounds.

    Science.gov (United States)

    Danny, Riethorst; Amitava, Mitra; Filippos, Kesisoglou; Wei, Xu; Jan, Tack; Joachim, Brouwers; Patrick, Augustijns

    2018-05-23

    In addition to individual intestinal fluid components, colloidal structures are responsible for enhancing the solubility of lipophilic compounds. The present study investigated the link between as well as the variability in the ultrastructure of fed state human intestinal fluids (FeHIF) and their solubilizing capacity for lipophilic compounds. For this purpose, FeHIF samples from 10 healthy volunteers with known composition and ultrastructure were used to determine the solubility of four lipophilic compounds. In light of the focus on solubility and ultrastructure, the study carefully considered the methodology of solubility determination in relation to colloid composition and solubilizing capacity of FeHIF. To determine the solubilizing capacity of human and simulated intestinal fluids, the samples were saturated with the compound of interest, shaken for 24 h, and centrifuged. When using FeHIF, solubilities were determined in the micellar layer of FeHIF, i.e. after removing the upper (lipid) layer (standard procedure), as well as in 'full' FeHIF (without removal of the upper layer). Compound concentrations were determined using HPLC-UV/fluorescence. To link the solubilizing capacity with the ultrastructure, all human and simulated fluids were imaged using transmission electron microscopy (TEM) before and after centrifugation and top layer (lipid) removal. Comparing the ultrastructure and solubilizing capacity of individual FeHIF samples demonstrated a high intersubject variability in postprandial intestinal conditions. Imaging of FeHIF after removal of the upper layer clearly showed that only micellar structures remain in the lower layer. This observation suggests that larger colloids such as vesicles and lipid droplets are contained in the upper, lipid layer. The solubilizing capacity of most FeHIF samples substantially increased with inclusion of this lipid layer. The relative increase in solubilizing capacity upon inclusion of the lipid layer was most pronounced

  14. The molecular genetics of crown gall tumorigenesis

    International Nuclear Information System (INIS)

    Hooykaas, P.J.J.; Schilperoort, R.A.

    1984-01-01

    The phytopathogenic bacteria Agrobacterium tumefaciens and A. rhizogenes are the causative agents of the widespread plant diseases ''crown gall'' and ''hairy root'' respectively. It is now well established that virulent strains of these bacterial species transfer a piece of bacterial DNA into plant cells, thereby transforming these into tumor cells. In research much attention has been paid to the agrobacteria for several reasons. First is the desire to develop a system for the genetic engineering of plant cells based on the natural system for gene transfer between Agrobacterium species and plant cells. Second, there is a striking resemblance between the etiology of animal cancers and the plant cancer crown gall that was recognized as early as in 1927. This led to basic studies on the process of plant tumor induction and on the recovery of plant cells from the tumorous state. A third important interest lies in crown gall as a disease that is the cause of economically important losses in agriculture an horticulture in Europe, North America, and Austrailia. Research has been aimed at finding means to prevent crown gall and to cure plants of this disease

  15. Asymptomatic ''crowned dens'' calcification in CT images for the craniovertebral junction

    International Nuclear Information System (INIS)

    Kubota, Gen; Mori, Masataka; Fukushima, Tatsuro

    2007-01-01

    Calcification around the odontoid process suggests 'crowned dens' syndrome, when accompanied with acute occipital headache or neck pain and with inflammatory signs. We retrospectively searched for calcification around the odontoid process in routine CT images of 282 patients emcompassing the craniovertebral junction, and found 13 (4.6%) had 'crowned dens' calcifications with neither characteristic symptoms nor signs suggestive for crowned dens' syndrome. Females of older ages frequently showed asymptomatic crowned dens' calcifications. (author)

  16. Dynamic SPECT of the brain using a lipophilic technetium-99m complex, PnAO

    DEFF Research Database (Denmark)

    Holm, S; Andersen, A R; Vorstrup, S

    1985-01-01

    m PnAO was injected i.v. as a bolus of 15 to 25 mCi. The distribution was followed over 10-sec intervals using a highly sensitive, rapidly rotating SPECT (Tomomatic 64) and compared to 133Xe flow maps. Upon arrival of the PnAO bolus to the brain, a high uptake was found in brain tissue with high......The lipophilic 99mTc-labeled oxime propylene amine oxime (PnAO) should, according to recent reports behave like 133Xe in the human brain. This study compares SPECT images of the two tracers in six subjects: four stroke cases, one transitory ischemic attack case and one normal subject. Technetium-99......AO has a high yet incomplete brain extraction yielding a flow dominated initial distribution with limitations mentioned....

  17. Acetylene–ammonia–18-crown-6 (1/2/1

    Directory of Open Access Journals (Sweden)

    Tobias Grassl

    2012-10-01

    Full Text Available The title compound, C2H2·C12H24O6·2NH3, was formed by co-crystallization of 18-crown-6 and acetylene in liquid ammonia. The 18-crown-6 molecule has threefold rotoinversion symmetry. The acteylene molecule lies on the threefold axis and the whole molecule is generated by an inversion center. The two ammonia molecules are also located on the threefold axis and are related by inversion symmetry. In the crystal, the ammonia molecules are located below and above the crown ether plane and are connected by intermolecular N—H...O hydrogen bonds. The acetylene molecules are additionally linked by weak C—H...N interactions into chains that propagate in the direction of the crystallographic c axis. The 18-crown-6 molecule [occupancy ratio 0.830 (4:0.170 (4] is disordered and was refined using a split model.

  18. Chemical composition of barks from Quercus faginea trees and characterization of their lipophilic and polar extracts.

    Science.gov (United States)

    Ferreira, Joana P A; Miranda, Isabel; Sousa, Vicelina B; Pereira, Helena

    2018-01-01

    The bark from Quercus faginea mature trees from two sites was chemically characterized for the first time. The barks showed the following composition: ash 14.6%, total extractives 13.2%, suberin 2.9% and lignin 28.2%. The polysaccharides were composed mainly of glucose and xylose (50.3% and 35.1% of all monosaccharides respectively) with 4.8% of uronic acids. The suberin composition was: ω-hydroxyacids 46.3% of total compounds, ɑ,ω-alkanoic diacids 22.3%, alkanoic acids 5.9%, alkanols 6.7% and aromatics 6.9% (ferulic acid 4.0%). Polar extracts (ethanol-water) had a high phenolic content of 630.3 mg of gallic acid equivalents (GAE)/g of extract, condensed tannins 220.7 mg of catechin equivalents (CE)/g extract, and flavonoids 207.7 mg CE/g of extract. The antioxidant activity was very high corresponding to 1567 mg Trolox equivalents/g of extract, and an IC50 of 2.63 μg extract/ml. The lipophilic extracts were constituted mainly by glycerol and its derivatives (12.3% of all compounds), alkanoic acids (27.8%), sterols (11.5%) and triterpenes (17.8%). In view of an integrated valorization, Quercus faginea barks are interesting sources of polar compounds including phenols and polyphenols with possible interesting bioactivities, while the sterols and triterpenes contained in the lipophilic extracts are also valuable bioactive compounds or chemical intermediates for specific high-value market niches, such as cosmetics, pharmaceuticals and biomedicine.

  19. Evaluation of sampling strategies to estimate crown biomass

    Directory of Open Access Journals (Sweden)

    Krishna P Poudel

    2015-01-01

    Full Text Available Background Depending on tree and site characteristics crown biomass accounts for a significant portion of the total aboveground biomass in the tree. Crown biomass estimation is useful for different purposes including evaluating the economic feasibility of crown utilization for energy production or forest products, fuel load assessments and fire management strategies, and wildfire modeling. However, crown biomass is difficult to predict because of the variability within and among species and sites. Thus the allometric equations used for predicting crown biomass should be based on data collected with precise and unbiased sampling strategies. In this study, we evaluate the performance different sampling strategies to estimate crown biomass and to evaluate the effect of sample size in estimating crown biomass. Methods Using data collected from 20 destructively sampled trees, we evaluated 11 different sampling strategies using six evaluation statistics: bias, relative bias, root mean square error (RMSE, relative RMSE, amount of biomass sampled, and relative biomass sampled. We also evaluated the performance of the selected sampling strategies when different numbers of branches (3, 6, 9, and 12 are selected from each tree. Tree specific log linear model with branch diameter and branch length as covariates was used to obtain individual branch biomass. Results Compared to all other methods stratified sampling with probability proportional to size estimation technique produced better results when three or six branches per tree were sampled. However, the systematic sampling with ratio estimation technique was the best when at least nine branches per tree were sampled. Under the stratified sampling strategy, selecting unequal number of branches per stratum produced approximately similar results to simple random sampling, but it further decreased RMSE when information on branch diameter is used in the design and estimation phases. Conclusions Use of

  20. Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns.

    Science.gov (United States)

    Kassem, Amr S; Atta, Osama; El-Mowafy, Omar

    2012-01-01

    The aim of this study was to determine effect of compressive cyclic loading on fatigue resistance and microleakage of monolithic CAD/CAM molar ceramic and composite crowns. Thirty-two extracted molars were prepared to receive CEREC crowns according to manufacturer's guidelines using a special paralleling device (Parallel-A-Prep). Sixteen feldspathic ceramic crowns (VITABLOCS Mark II) (VMII) and 16 resin-composite crowns (Paradigm-MZ100 blocks) (PMZ) were milled using a CEREC-3D machine. Eight crowns of each group were cemented to their respective teeth using self-etching resin cement (Panavia-F-2.0) (PAN), and eight were cemented using self-adhesive resin cement (RelyX-Unicem-Clicker) (RXU). Following storage for 1 week in water, specimens were subjected to uniaxial compressive cyclic loading in an Instron testing machine at 12 Hz for 1,000,000 cycles. Load was applied at the central fossa, and the cycle range was 60-600 N. Specimens were then subjected to microleakage testing. Data were statistically analyzed using factorial ANOVA and Post Hoc (Tukey HSD) tests. All composite crowns survived compressive cyclic loading without fracture, while three ceramic crowns from the subgroup cemented with RXU developed surface cracks at the center of occlusal surfaces, extending laterally. Microleakage scores of ceramic crowns cemented with PAN were significantly lower than those of the other three subgroups (p < 0.05). After 1,000,000 cycles of compressive cyclic loading, PMZ composite molar crowns were more fatigue-resistant than VMII ceramic crowns. Cement type had a significant effect on fatigue resistance of the ceramic crowns but not the composite ones. Microleakage scores of ceramic crowns cemented with PAN were significantly lower than those of the other subgroups (p < 0.05). © 2011 by The American College of Prosthodontists.

  1. 30 CFR 250.404 - What are the requirements for the crown block?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What are the requirements for the crown block... General Requirements § 250.404 What are the requirements for the crown block? You must have a crown block safety device that prevents the traveling block from striking the crown block. You must check the device...

  2. Spectrophotometric evaluation of crown fragment a year after ...

    African Journals Online (AJOL)

    Background: Crown fracture is the most common type of fracture and frequently affects the anterior teeth. Crown fractures have been treated in several ways depending on the location and kind of fracture. This case emphasizes reattachment of fractured fragments using fiber-reinforced post. Also this case report underlines ...

  3. SYNTHESIS OF 4’-ALLYLBENZO-3N-CROWN-N ETHERS AND THEIR MASS SPECTRA COMPARED WITH BENZO-3N-CROWN-N ETHERS

    OpenAIRE

    Anwar, Chairil

    2008-01-01

    Synthesis of 4’allylbenzo-3n-crown-n ethers was carried out by reacting demethylated eugenol with α,ω-dichloro-oligoethylene glycols in 1-butanol under basic condition. The mass spectra of 4’allylbenzo-3n-crown-n and benzo-3n-crown-n were investigated by mass spectrometry using electron impact under 70 eV of electron bombardment as ionisation method. The difference between the group of compounds is only the present of allyl moiety as a side chain at the other side of benzene ring. The first g...

  4. Evaluation of effectiveness of cement removal from implant-retained crowns using a proposed circular crisscross flossing technique.

    Science.gov (United States)

    Ferreira, Cimara Fortes; Shafter, Mohamed Amer; Jain, Vinay; Wicks, Russel Anthony; Linder, Erno; Ledo, Carlos Alberto da Silva

    2018-02-13

    Extruded cement during dental implant crown cementation may cause peri-implant diseases if not removed adequately. Evaluate the efficiency of removal of cement after cementation of implant crowns using an experimental "circular crisscross flossing technique (CCCFT) flossing technique, compared to the conventional "C" shape flossing technique (CSFT). Twenty-four patients rendered 29 experimental and 29 control crowns. Prefabricated abutments were secured to the implant with the margins at least 1 mm subgingivally. The abutments were scanned using CADCAM technology and Emax crowns were fabricated in duplicates. Each crown was cemented separately and excess cement was removed using the CSFT and the CCFT techniques. After completion of cementation was completed, the screw access holes were accessed and the crown was unscrewed along with the abutment. The samples were disinfected using 70% ethanol for 10 minutes. Crowns were divided into 4 parts using a marker in order to facilitate measurement data collection. Vertical and horizontal measurements were made for extruded cement for each control and experimental groups by means of a digital microscope. One-hundred and seventeen measurements were made for each group. Mann-Whitney test was applied to verify statistical significance between the groups. The CCFT showed a highly statistically significant result (104.8 ± 13.66, pcrowns cementation when compared with the CSFT.

  5. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns

    Directory of Open Access Journals (Sweden)

    Adil Othman ABDULLAH

    Full Text Available ABSTRACT Objective This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. Material and Methods An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone “PEEK”, Telio CAD-Temp, and Protemp™4 (control group. The crowns were divided into four groups (n=10, Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. Results The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99 µm, PEEK 46.75 (±8.26 µm, Telio CAD-Temp 56.10 (±5.65 µm, and Protemp™4 193.07(±35.96 µm (P0.05. Conclusions CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  6. Ionic complexation of N 2O 4 by 18-crown-6

    Science.gov (United States)

    Ricard, S.; Audet, P.; Savoie, R.

    1988-08-01

    An ionic complex has been obtained from N 2O 4 in the presence of the macrocyclic ether 18-crown-6. This crystalline compound has been shown from its Raman spectrum to have the formula NO +·crown·H(NO 3) 2-, with the nitrosonium ion closely associated with the crown ether rather than with the hydrogen dinitrate accompanying ion. This adduct decomposes readily in moist air to give the known complex (HNO 3·H 2O) 2·crown.

  7. Crown-level tree species classification from AISA hyperspectral imagery using an innovative pixel-weighting approach

    Science.gov (United States)

    Liu, Haijian; Wu, Changshan

    2018-06-01

    Crown-level tree species classification is a challenging task due to the spectral similarity among different tree species. Shadow, underlying objects, and other materials within a crown may decrease the purity of extracted crown spectra and further reduce classification accuracy. To address this problem, an innovative pixel-weighting approach was developed for tree species classification at the crown level. The method utilized high density discrete LiDAR data for individual tree delineation and Airborne Imaging Spectrometer for Applications (AISA) hyperspectral imagery for pure crown-scale spectra extraction. Specifically, three steps were included: 1) individual tree identification using LiDAR data, 2) pixel-weighted representative crown spectra calculation using hyperspectral imagery, with which pixel-based illuminated-leaf fractions estimated using a linear spectral mixture analysis (LSMA) were employed as weighted factors, and 3) representative spectra based tree species classification was performed through applying a support vector machine (SVM) approach. Analysis of results suggests that the developed pixel-weighting approach (OA = 82.12%, Kc = 0.74) performed better than treetop-based (OA = 70.86%, Kc = 0.58) and pixel-majority methods (OA = 72.26, Kc = 0.62) in terms of classification accuracy. McNemar tests indicated the differences in accuracy between pixel-weighting and treetop-based approaches as well as that between pixel-weighting and pixel-majority approaches were statistically significant.

  8. Marginal Assessment of Crowns by the Aid of Parallel Radiography

    Directory of Open Access Journals (Sweden)

    Farnaz Fattahi

    2015-03-01

    Full Text Available Introduction: Marginal adaptation is the most critical item in long-term prognosis of single crowns. This study aimed to assess the marginal quality as well asthe discrepancies in marginal integrity of some PFM single crowns of posterior teeth by employing parallel radiography in Shiraz Dental School, Shiraz, Iran. Methods: In this descriptive study, parallel radiographies were taken from 200 fabricated PFM single crowns of posterior teeth after cementation and before discharging the patient. To calculate the magnification of the images, a metallic sphere with the thickness of 4 mm was placed in the direction of the crown margin on the occlusal surface. Thereafter, the horizontal and vertical space between the crown margins, the margin of preparations and also the vertical space between the crown margin and the bone crest were measured by using digital radiological software. Results: Analysis of data by descriptive statistics revealed that 75.5% and 60% of the cases had more than the acceptable space (50µm in the vertical (130±20µm and horizontal (90±15µm dimensions, respectively. Moreover, 85% of patients were found to have either horizontal or vertical gap. In 77% of cases, the margins of crowns invaded the biologic width in the mesial and 70% in distal surfaces. Conclusion: Parallel radiography can be expedient in the stage of framework try-in to yield some important information that cannot be obtained by routine clinical evaluations and may improve the treatment prognosis

  9. FEM and Von Mises Analysis on Prosthetic Crowns Structural Elements: Evaluation of Different Applied Materials

    Directory of Open Access Journals (Sweden)

    Ennio Bramanti

    2017-01-01

    Full Text Available The aim of this paper is to underline the mechanical properties of dental single crown prosthodontics materials in order to differentiate the possibility of using each material for typical clinical condition and masticatory load. Objective of the investigation is to highlight the stress distribution over different common dental crowns by using computer-aided design software and a three-dimensional virtual model. By using engineering systems of analyses like FEM and Von Mises investigations it has been highlighted the strength over simulated lower first premolar crowns made by chrome cobalt alloy, golden alloy, dental resin, and zirconia. The prosthodontics crown models have been created and put on simulated chewing stresses. The three-dimensional models were subjected to axial and oblique forces and both guaranteed expected results over simulated masticatory cycle. Dental resin presented the low value of fracture while high values have been recorded for the metal alloy and zirconia. Clinicians should choose the better prosthetic solution for the teeth they want to restore and replace. Both prosthetic dental crowns offer long-term success if applied following the manufacture guide limitations and suggestions.

  10. Evaluation of ACE inhibitors lipophilicity using in silico and chromatographically obtained hydrophobicity parameters

    Directory of Open Access Journals (Sweden)

    Odović Jadranka V.

    2013-01-01

    Full Text Available The aim of this study was to compare different calculation methods to determine lipophilicity, expressed as logP value, of seven ACE inhibitors (enalapril, quinapril, fosinopril, lisinopril, cilazapril, ramipril, and benazapril with significantly different structure. Experimentally determined n-octanol/water partition coefficients, logPO/W values, were obtained from relevant literature. The correlations between all collected logP values were studied and the best agreements between calculated logP and experimentally determined logPO/W values, were observed for KOWWINlogP or MilogP values (r = 0.999 or r = 0.974, respectively. The correlations between all collected logP values and chromatographically (reversed-phase thin-layer chromatography obtained hydrophobicity parameters, RM0 and C0, were established. The good correlations (r > 0.90 were obtained in the majority of relationships. The KOWWINlogP was established as the most suitable hydrophobicity parameter of investigated group of ACE inhibitors with r = 0.981 for correlation with RM0 and r = 0.977 for correlation with C0 parameters (water-methanol mobile phase. Using multiple linear regressions, it was established that application of two selected logP, calculated by different mathematical approaches, led to very good correlation due to the benefits of both calculation methods. The good relationships indicate that the computed logP, with careful selection of method calculation, can be useful in ACE inhibitors lipophilicity evaluation, as high-throughput screening technique.

  11. Displacement of screw-retained single crowns into implants with conical internal connections.

    Science.gov (United States)

    Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Internal conical implant-abutment connections without platforms may lead to axial displacement of crowns during screw tightening. This displacement may affect proximal contacts, incisal edge position, or occlusion. This study aimed to measure the displacement of screw-retained single crowns into an implant in three dimensions during screw tightening by hand or via torque driver. A stereolithic acrylic resin cast was created using computed tomography data from a patient missing the maxillary right central incisor. A 4.0- × 11-mm implant was placed in the edentulous site. Five porcelain-fused-to-metal single crowns were made using "cast-to" abutments. Crowns were tried on the stereolithic model, representing the patient, and hand tightened. The spatial relationship of crowns to the model after hand tightening was determined using three-dimensional digital image correlation (3D DIC), an optical measurement technique. The crowns were then tightened using a torque driver to 20 Ncm and the relative crown positions were again recorded. Testing was repeated three times for each crown, and displacement of the crowns was compared between the hand-tightened and torqued states. Commercial image correlation software was used to analyze the data. Mean vertical and horizontal crown displacement values were calculated after torqueing. The interproximal contacts were evaluated before and after torquing using an 8-μm aluminum foil shim. There were vertical and horizontal differences in crown positions between hand tightening and torqueing. Although these were small in magnitude, detectable displacements occurred in both apical and facial directions. After hand tightening, the 8-μm shim could be dragged without tearing. However, after torque tightening, the interproximal contacts were too tight and the 8-μm shim could not be dragged without tearing. Differences between hand tightening and torque tightening should be taken into consideration during laboratory and clinical

  12. Automatic crown cover mapping to improve forest inventory

    Science.gov (United States)

    Claude Vidal; Jean-Guy Boureau; Nicolas Robert; Nicolas Py; Josiane Zerubia; Xavier Descombes; Guillaume Perrin

    2009-01-01

    To automatically analyze near infrared aerial photographs, the French National Institute for Research in Computer Science and Control developed together with the French National Forest Inventory (NFI) a method for automatic crown cover mapping. This method uses a Reverse Jump Monte Carlo Markov Chain algorithm to locate the crowns and describe those using ellipses or...

  13. Biomedical potentials of crown ethers: prospective antitumor agents.

    Science.gov (United States)

    Kralj, Marijeta; Tusek-Bozić, Ljerka; Frkanec, Leo

    2008-10-01

    Crown ethers are of enormous interest and importance in chemistry, biochemistry, materials science, catalysis, separation, transport and encapsulated processes, as well as in the design and synthesis of various synthetic systems with specific properties, diverse capabilities, and programmable functions. Classical crown ethers are macrocyclic polyethers that contain 3-20 oxygen atoms separated from each other by two or more carbon atoms. They are exceptionally versatile in selectively binding a range of metal ions and a variety of organic neutral and ionic species. Crown ethers are currently being studied and used in a variety of applications beyond their traditional place in chemistry. This review presents additional applications and the ever-increasing biomedical potentials of these intriguing compounds, with particular emphasis on the prospects of their relevance as anticancer agents. We believe that further research in this direction should be encouraged, as crown compounds could either induce toxicities that are different from those of conventional antitumor drugs, or complement drugs in current use, thereby providing a valuable adjunct to therapy.

  14. Persistent organic pollutants in red-crowned cranes (Grus japonensis) from Hokkaido, Japan.

    Science.gov (United States)

    Kakimoto, Kensaku; Akutsu, Kazuhiko; Nagayoshi, Haruna; Konishi, Yoshimasa; Kajimura, Keiji; Tsukue, Naomi; Yoshino, Tomoo; Matsumoto, Fumio; Nakano, Takeshi; Tang, Ning; Hayakawa, Kazuichi; Toriba, Akira

    2018-01-01

    The red-crowned crane (Grus japonensis) from eastern Hokkaido is classified as a Special Natural Monument in Japan. In this study, we determined the concentrations of persistent organic pollutants (POPs) in red-crowned crane muscle tissues (n = 47). Polychlorinated biphenyls (PCBs) had the highest median concentration (240ng/g lipid weight), followed by dichlorodiphenyltrichloroethane and its metabolites (DDTs) (150ng/g lipid weight), chlordane-related compounds (CHLs) (36ng/g lipid weight), hexachlorobenzene (HCB) (16ng/g lipid weight), hexachlorocyclohexanes (HCHs) (4.4ng/g lipid weight), polybrominated diphenyl ethers (PBDEs) (1.8ng/g lipid weight), and finally, Mirex (1.5ng/g lipid weight). Additionally, a positive correlation was found among POP concentrations. No sex differences beyond body parameters were observed. Additionally, red-crowned cranes exhibited a high enantiomeric excess of (+)-alpha-HCH, with enantiomer fractions varying from 0.51 to 0.87 (average: 0.69). Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Clinical performance of IPS-Empress 2 ceramic crowns inserted by general dental practitioners.

    Science.gov (United States)

    Mansour, Yasar F; Al-Omiri, Mahmoud K; Khader, Yousef Saleh; Al-Wahadni, Ahed

    2008-05-01

    The aim of this study was to evaluate the clinical performance of IPS-Empress 2(R) all-ceramic crowns placed by general dental practitioners. Eighty-two IPS-Empress 2 crowns placed in 64 patients (27 females and 37 males) were evaluated. These crowns had been in place for 15.2 to 57.2 months (mean 25.3 months, SD=9.3). Survival analysis was conducted using the Kaplan-Meier method. Of the 82 crowns 93.9% were rated satisfactory. In terms of the integrity of the restorations, fracture was observed in three crowns and two showed a crack upon transillumination. Five crowns were rated unsatisfactory for color match; one for marginal adaptation; and none for discoloration, secondary caries, or sensitivity. IPS-Empress 2(R) is a suitable material to fabricate all-ceramic crowns; when these all-ceramic crowns were inserted by general dental practitioners, they functioned satisfactorily with low failure rates during an observation period ranging between 15.2 to 57.2 months.

  16. The marginal fit of selective laser melting-fabricated metal crowns: an in vitro study.

    Science.gov (United States)

    Xu, Dan; Xiang, Nan; Wei, Bin

    2014-12-01

    The selective laser melting technique is attracting interest in prosthetic dentistry. The marginal fit is a key criterion for fixed restorations. The purpose of the study was to evaluate the marginal fit of cast cobalt-chromium alloy crowns versus the fit of selective laser melting-fabricated crowns. The marginal gap widths of 36 single crowns (18 selective laser melting-fabricated cobalt-chromium metal crowns and 18 cobalt-chromium cast crowns) were determined with a silicone replica technique. Each crown specimen was cut into 4 sections, and the marginal gap width of each cross section was evaluated by stereomicroscopy (× 100). The Student t test was used to evaluate whether significant differences occurred in the marginal gap widths between the selective laser melting-fabricated and cast cobalt-chromium metal crowns (α=.05). The mean marginal gap width of the cast crowns (170.19 μm) was significantly wider than that of the selective laser melting-fabricated crowns (102.86 μm). Selective laser melting-fabricate cobalt-chromium dental crowns found improved marginal gap widths compared with traditional cast crowns. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  17. Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis.

    Science.gov (United States)

    Verri, Fellippo Ramos; Batista, Victor Eduardo de Souza; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Pellizzer, Eduardo Piza

    2014-12-01

    The aim of this study was to evaluate stress distribution in the fixation screws and bone tissue around implants in single-implant supported prostheses with crowns of different heights (10, 12.5, 15 mm - crown-to-implant ratio 1:1, 1.25:1, 1.5:1, respectively). It was designed using three 3-D models. Each model was developed with a mandibular segment of bone block including an internal hexagon implant supporting a screw-retained, single metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm with crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. The applied forces were 200N (axial) and 100 N (oblique). The increase of crown height showed differences with the oblique load in some situations. By von Mises' criterion, a high stress area was concentrated at the implant/fixation screw and abutment/implant interfaces at crown-to-implant ratio of 1:1, 1.25:1, 1.5:1, respectively. Using the maximum principal criteria, the buccal regions showed higher traction stress intensity, whereas the distal regions showed the largest compressive stress in all models. The increase of C/I ratio must be carefully evaluated by the dentist since the increase of this C/I ratio is proportional to the increase of average stress for both screw fixation (C/I 1:1 to 1:1.25 ratio=30.1% and C/I 1:1 to 1:1.5 ratio=46.3%) and bone tissue (C/I 1:1 to 1:1.25 ratio=30% and C/I 1:1 to 1:1.5 ratio=51.5%). Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Online recovery of radiocesium from soil, cellulose and plant samples by supercritical fluid extraction employing crown ethers and calix-crown derivatives as extractants

    International Nuclear Information System (INIS)

    Kanekar, A.S.; Pathak, P.N.; Mohapatra, P.K.

    2014-01-01

    Two crown ethers (CEs) viz. dibenzo18crown6, and dibenzo12crown7 and three calix-crown derivatives viz. (octyloxy)calix[4]arene-mono-crown-6 (CMC), calix[4]arene-bis(o-benzocrown-6) (CBC), and calix[4]arene-bis(naphthocrown-6) (CNC) were evaluated for the recovery of 137 Cs from synthetic soil, cellulose (tissue paper), and plant samples by supercritical fluid extraction (SFE) route. CEs showed poor extraction of 137 Cs from soil matrix. SFE experiments using 1 × 10 -3 M solutions of CMC, CBC and CNC in acetonitrile at 3 M HNO 3 as modifiers displayed better extraction of 137 Cs, viz. 21(±2) % (CMC), 16.5(±3) % (CBC), and 4(±1) % (CNC). It was not possible to recover 137 Cs quantitatively from soil matrix. The inefficient extraction of 137 Cs from soil matrix was attributed to its incorporation into the interstitial sites. Experiments on tissue papers using CMC showed near quantitative 137 Cs recovery. On the other hand, recovery from plant samples varied between 50(±5) % (for stems) and 75(±5) % (for leaves). (author)

  19. Experiments on the breakup of drop-impact crowns by Marangoni holes

    KAUST Repository

    Aljedaani, Abdulrahman Barakat; Wang, Chunliang; Jetly, Aditya; Thoroddsen, Sigurdur T

    2018-01-01

    We investigate experimentally the breakup of the Edgerton crown due to Marangoni instability when a highly viscous drop impacts on a thin film of lower-viscosity liquid, which also has different surface tension than the drop liquid. The presence

  20. Influence of implant position on clinical crown length and peri-implant soft tissue dimensions at implant-supported single crowns replacing maxillary central incisors

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2013-01-01

    The aims of the present study were to evaluate the influence of implant position on clinical crown length and marginal soft tissue dimensions at implant-supported single crowns of maxillary central incisors, and to validate the papilla index score (PIS). Twenty-five patients, who had lost one of ...... abutments and did not necessarily result in an increased crown length. The distal implant papilla heightwas obviously shorter, althoughthe mesial papilla height was similar to thatof the healthy dentition.The papilla index score was tested to be a valid index for papilla fill....

  1. Selective crystallization of cations with crown ethers; Selektive Kristallisation von Kationen mit Kronenethern

    Energy Technology Data Exchange (ETDEWEB)

    Heffels, Dennis Egidius

    2014-07-04

    The aim of this work was to study the selectivity and preferences of the incorporation of differently sized cations in the cavities of various crown ethers and the characterization of the resulting compounds. The coordination preferences of crown ethers with different cavities have long been known, and the impact of other effects on the structure formation have increasingly become the focus of attention. In this work a comparative overview of the coordination preferences depending on various factors was undertaken. The focus was mainly on the variation of the cavity of the crown ether in the presence of differently sized cations. In addition, the effects of the solvent and differently coordinating anions have been investigated. Within the framework of this work, basic coordination preferences could be detected with rare earth nitrates, which are affected particularly by the choice of the solvent. The formation of different types of structures could be controlled by varying the conditions such that the incorporation of the cation in the cavity of the crown ether was influenced and the formation of a particular type of structure can be influenced partly by the choice of solvent. In this case no direct preferences for the incorporation into the cavity of the crown ether in relation to the cation size were observed for rare earth cations. However, the coordination of the crown ether leads in each case - for lanthanides - to rather high coordination numbers. A total of five new rare earth complexes and two structural variants could be observed with crown ethers. In the study of the selectivity of the incorporation into the cavity, known structures were also reproduced and further structures were characterized but the crystal structures not entirely solved. With the use of monovalent cations such as potassium, lithium or silver a total of nine new compounds could be synthesized, while no clear preferences for the incorporation of certain cations were detected. The

  2. Elliptic Fourier analysis of crown shapes in Quercus petraea trees

    OpenAIRE

    Ovidiu Hâruţa

    2011-01-01

    Shape is a fundamental morphological descriptor, significant in taxonomic research as well as in ecomorphology, one method of estimation being from digitally processed images. In the present study, were analysed shapes of Q. petraea crowns, pertaining to five different stem diameter classes, from three similar stands. Based on measurements on terrestrial digital vertical photos, crown size analysis was performed and correlations between crown and stem variables were tested. Linear regression ...

  3. Fractal approach to computer-analytical modelling of tree crown

    International Nuclear Information System (INIS)

    Berezovskaya, F.S.; Karev, G.P.; Kisliuk, O.F.; Khlebopros, R.G.; Tcelniker, Yu.L.

    1993-09-01

    In this paper we discuss three approaches to the modeling of a tree crown development. These approaches are experimental (i.e. regressive), theoretical (i.e. analytical) and simulation (i.e. computer) modeling. The common assumption of these is that a tree can be regarded as one of the fractal objects which is the collection of semi-similar objects and combines the properties of two- and three-dimensional bodies. We show that a fractal measure of crown can be used as the link between the mathematical models of crown growth and light propagation through canopy. The computer approach gives the possibility to visualize a crown development and to calibrate the model on experimental data. In the paper different stages of the above-mentioned approaches are described. The experimental data for spruce, the description of computer system for modeling and the variant of computer model are presented. (author). 9 refs, 4 figs

  4. Determination of stability constants of K and Cs nitrate complex with dicyclohexyl-18-crown-6 and dibenzo-18-crown-6 in isopropanol aqueous solutions

    International Nuclear Information System (INIS)

    Myasoedova, T.G.; Ponomareva, A.V.; Zagorets, P.A.; Filippov, E.A.

    1984-01-01

    Total stability constants of K and Cs nitrate complexes with dicyclohexyl-18-crown-6 and dibenzo-18-crown-6 in isopropanol aqueous solutions were determined by the method of low-frequency contact conductometry. Clearly defined K/Cs selectivity is observed for the system with dibenzo-18-crown-6. It is shown that lgβ depends on permittivity of the solvent. The decrease of permittivity of isopropanol aqueous solutions results in reduction of K/Cs selectivity of DB18C6

  5. Determination of stability constants of K and Cs nitrate complex with dicyclohexyl-18-crown-6 and dibenzo-18-crown-6 in isopropanol aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Myasoedova, T G; Ponomareva, A V; Zagorets, P A; Filippov, E A [Moskovskij Khimiko-Tekhnologicheskij Inst. (USSR)

    1984-08-01

    Total stability constants of K and Cs nitrate complexes with dicyclohexyl-18-crown-6 and dibenzo-18-crown-6 in isopropanol aqueous solutions were determined by the method of low-frequency contact conductometry. Clearly defined K/Cs selectivity is observed for the system with dibenzo-18-crown-6. It is shown that lg..beta.. depends on permittivity of the solvent. The decrease of permittivity of isopropanol aqueous solutions results in reduction of K/Cs selectivity of DB18C6.

  6. RICHMOND CROWN - FOR RESTORATION OF BADLY MUTILATED POSTERIOR TEETH : A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Yadav

    2015-07-01

    Full Text Available Restoration of badly broken endodontically treated teeth is a common problem in restorative dentistry. Such teeth often require additional support from the root canal by means of a post and core restoration. In cases where tooth structure is significantly lost full coverage restorations for posterior teeth are necessary to achieve proper tooth form and function. Badly broken teeth with minimal or no crown structure require added retention and support. The Richmond crown can be a good treatment alternative for restoration of such teeth. The Richmond crown was introduced in 1878 and incorporated a threaded tube in the canal with a screw retained crown. It was later modified to eliminate the threaded tube and was redesigned as a one piece dowel and crown. This case report shows restoration of badly mutilated posterior teeth with Richmond crown.

  7. Functionalized mesoporous silicas with crown ether moieties for selective adsorption of lithium ions in artificial sea water.

    Science.gov (United States)

    Sung, Soo Park; Moorthy, Madhappan Santha; Song, Hyun-Jin; Ha, Chang-Sik

    2014-11-01

    Lithium ion has been increasingly recognized in a wide range of industrial applications. In this work, we studied on the adsorption of Li+ in the artificial seawater with high selectivity using methyl-crown ether (AC-SBA-15) and aza-crown ether (HMC-SBA-15) moieties-functionalized mesoporous silica materials. First, methyl-crown ether and aza-crown ether moieties-functionalized mesoporous silica materials were synthesized via two-step post-synthesis process using a grafting method. The functionalized materials were employed to the metal ion adsorption from aqueous solution (artificial seawater) containing Li+, Co2+, Cr3+ and Hg2+. The prepared hybrid material showed high selectivity for Li+ ion in the artificial seawater at pH 8.0. The absorbed amount of Li+ was 73 times higher than Cr3+ for aza-crown ether containing AC-SBA-15 as an absorbent. The absorbed amount of Co2+ (4.5 x 10(-5) mol/g), Cr3+ (1.5 x 10(-5) mol/g) and Hg2+ (2.25 x 10(-4) mol/g) were remarkably lower than the case of Li+. On the other hand, the absorbed amount of various metal ions of HMC-SBA-15 with amine groups in alky chains and crown ether moieties were 1.1 x 10(-3) mol/g for Li+, 5.0 x 10(-5) mol/g for Co2+, 2.9 x 10(-4) mol/g for Cr3+, 2.8 x 10(-4) mol/g for Hg2+ mol/g, respectively.

  8. Rapid crown root development confers tolerance to zinc deficiency in rice

    Directory of Open Access Journals (Sweden)

    Amrit Kaur eNanda

    2016-03-01

    Full Text Available Zinc (Zn deficiency is one of the leading nutrient disorders in rice (Oryza sativa. Many studies have identified Zn efficient rice genotypes, but causal mechanisms for Zn deficiency tolerance remain poorly understood. Here we report a detailed study of the impact of Zn deficiency on crown root development of rice genotypes, differing in their tolerance to this stress. Zn deficiency delayed crown root development and plant biomass accumulation in both Zn efficient and inefficient genotypes, with the effects being much stronger in the latter. Zn efficient genotypes had developed new crown roots as early as three days after transplanting (DAT to a Zn deficient field and that was followed by a significant increase in total biomass by 7 DAT. Zn-inefficient genotypes developed few new crown roots and did not increase biomass during the first seven days following transplanting. This correlated with Zn efficient genotypes retranslocating a higher proportion of shoot Zn to their roots, compared to Zn inefficient genotypes. These latter genotypes were furthermore not efficient in utilizing the limited Zn for root development. Histological analyses indicated no anomalies in crown tissue of Zn-efficient or inefficient genotypes that would have suggested crown root emergence was impeded. We therefore conclude that the rate of crown root initiation was differentially affected by Zn deficiency between genotypes. Rapid crown root development, following transplanting, was identified as a main causative trait for tolerance to Zn deficiency and better Zn retranslocation from shoot to root was a key attribute of Zn-efficient genotypes.

  9. Built historiography in Glasgow’s New Gorbals – the Crown Street Regeneration Project

    Directory of Open Access Journals (Sweden)

    Florian Urban

    2011-12-01

    Full Text Available In 2000, the Crown Street redevelopment in Glasgow’s New Gorbals was completed after a master plan by Piers Gough of the London firm CZWG. Built on symbolically contested grounds that were previously occupied by the Gorbals tenements (1870s-1960s and the high-rise Hutchesontown flats (1960s-1990s, the new development is a textbook example of neo-traditional design. This article looks at the Crown Street redevelopment as a form of built historiography that inscribes a harmonized account of the past into the urban fabric. Like a written narrative, plan and buildings convey a historic narrative through tropes and character types. The historiographic dimension of the Crown Street redevelopment works on three levels. There is the site, which in various moments in the twentieth century came to signify the urban ‘other’ – the city’s underbelly of crime, plight, and misery – and which, as a result of both gentrification and architectural redesign, is now apparently pacified. There are carefully chosen historic references such as tenement façades, bay windows, underpasses, courtyards, and rues corridors, which communicate certain conceptions about recent history. And there is a municipal strategy for Glasgow’s economic revival, of which the re-writing of history is a part, and which, among others, makes use of the Crown Street redevelopment’s architectural imagery. On all three levels the Crown Street redevelopment reconciles conflicting perspectives: on the one hand a break almost as comprehensive as the modernist upheaval, which involved complete redesign and exchange of the population, and on the other hand the conception of historical continuity and long-lasting community life. Conveying a historical image cleared of ambiguities and imperfections, the Crown Street redevelopment thus communicates a message of both renewal and permanence.

  10. CAD/CAM glass ceramics for single-tooth implant crowns: a finite element analysis.

    Science.gov (United States)

    Akça, Kvanç; Cavusoglu, Yeliz; Sagirkaya, Elcin; Aybar, Buket; Cehreli, Murat Cavit

    2013-12-01

    To evaluate the load distribution of CAD/CAM mono-ceramic crowns supported with single-tooth implants in functional area. A 3-dimensional numerical model of a soft tissue-level implant was constructed with cement-retained abutment to support glass ceramic machinable crown. Implant-abutment complex and the retained crown were embedded in a Ø 1.5 × 1.5 cm geometric matrix for evaluation of mechanical behavior of mono-ceramic CAD/CAM aluminosilicate and leucite glass crown materials. Laterally positioned axial load of 300 N was applied on the crowns. Resulting principal stresses in the mono-ceramic crowns were evaluated in relation to different glass ceramic materials. The highest compressive stresses were observed at the cervical region of the buccal aspect of the crowns and were 89.98 and 89.99 MPa, for aluminosilicate and leucite glass ceramics, respectively. The highest tensile stresses were observed at the collar of the lingual part of the crowns and were 24.54 and 25.39 MPa, respectively. Stresses induced upon 300 N static loading of CAD/CAM aluminosalicate and leucite glass ceramics are below the compressive strength of the materials. Impact loads may actuate the progress to end failure of mono-ceramic crowns supported by metallic implant abutments.

  11. Estimation hydrophilic-lipophilic balance number of surfactants

    Energy Technology Data Exchange (ETDEWEB)

    Pawignya, Harsa, E-mail: harsa-paw@yahoo.co.id [Chemical Engineering Department Diponegoro University (Indonesia); Chemical Engineering Departement University of Pembangunan Nasional Yogyakarta (Indonesia); Prasetyaningrum, Aji, E-mail: ajiprasetyaningrum@gmail.com; Kusworo, Tutuk D.; Pramudono, Bambang, E-mail: Pramudono2004@yahoo.com [Chemical Engineering Department Diponegoro University (Indonesia); Dyartanti, Endah R. [Chemical Engineering Department Diponegoro University (Indonesia); Chemical Enginering Departement Sebelas Maret University (Indonesia)

    2016-02-08

    Any type of surfactant has a hydrophilic-lipophilic balance number (HLB number) of different. There are several methods for determining the HLB number, with ohysical properties of surfactant (solubility cloud point and interfacial tension), CMC methods and by thermodynamics properties (Free energy Gibbs). This paper proposes to determined HLB numbers from interfelation methods. The result of study indicated that the CMC method described by Hair and Moulik espesially for nonionic surfactant. The application of exess Gibbs free energy and by implication activity coefficient provides the ability to predict the behavior of surfactants in multi component mixtures of different concentration. Determination of HLB number by solubility and cloud point parameter is spesific for anionic and nonionic surfactant but this methods not available for cationic surfactants.

  12. Evaluation of different sterilization and disinfection methods on commercially made preformed crowns.

    Science.gov (United States)

    Yilmaz, Y; Guler, C

    2008-12-01

    The aim of this study was to evaluate the changes caused by different sterilization or disinfection methods on the vestibular surface of four commercially made preformed crowns using stereomicroscopy and scanning electron microscopy (SEM). Preformed crowns (NuSmile Primary Anterior Crown (NSC), Kinder Krowns (KK), Pedo Pearls (PP) and polycarbonate crowns (PC)) were sterilized and/or disinfected by one of the following techniques: no sterilization or disinfection (G1 control group); steam autoclaving at 134 degrees C (30 psi) for 4 min (G2); steam autoclaving at 134 degrees C (30 psi) for 12 min (G3); steam autoclaving at 121 degrees C (15 psi) for 30 min (G4); and ultrasonication in a bath containing 4% Lysetol AF for 5 min at room temperature (chemical disinfection) (G5). Scanning electron micrographs of the crowns were taken before and after their sterilization or disinfection. The changes on the vestibular surface were then scored for the presence or absence of crazing, contour alteration, fracturing, and vestibular surface changes. The data were analyzed statistically using the chi-square test. No changes were observed before and after sterilization or disinfection in the stereomicroscopic evaluation of the vestibular surface of the crowns. However, all methods in which steam autoclaving was used to sterilize the crowns caused significant (P < 0.05) crazing and contour alterations of the vestibular surface of the crowns when they were examined by SEM. Chemical disinfection using an aldehyde-free disinfectant is the preferred method of disinfection for crowns that have been used previously in other dental patients.

  13. Influence of the preparation design and artificial aging on the fracture resistance of monolithic zirconia crowns.

    Science.gov (United States)

    Mitov, Gergo; Anastassova-Yoshida, Yana; Nothdurft, Frank Phillip; von See, Constantin; Pospiech, Peter

    2016-02-01

    The aim of this study was to evaluate the fracture resistance and fracture behavior of monolithic zirconia crowns in accordance with the preparation design and aging simulation method. An upper first molar was prepared sequentially with three different preparation designs: shoulderless preparation, 0.4 mm chamfer and 0.8 mm chamfer preparation. For each preparation design, 30 monolithic zirconia crowns were fabricated. After cementation on Cr-Co alloy dies, the following artificial aging procedures were performed: (1) thermal cycling and mechanical loading (TCML): 5000 cycles of thermal cycling 5℃-55℃ and chewing simulation (1,200,000 cycles, 50 N); (2) Low Temperature Degradation simulation (LTD): autoclave treatment at 137℃, 2 bar for 3 hours and chewing simulation; and (3) no pre-treatment (control group). After artificial aging, the crowns were loaded until fracture. The mean values of fracture resistance varied between 3414 N (LTD; 0.8 mm chamfer preparation) and 5712 N (control group; shoulderless preparation). Two-way ANOVA analysis showed a significantly higher fracture loads for the shoulderless preparation, whereas no difference was found between the chamfer preparations. In contrast to TCML, after LTD simulation the fracture strength of monolithic zirconia crowns decreased significantly. The monolithic crowns tested in this study showed generally high fracture load values. Preparation design and LTD simulation had a significant influence on the fracture strength of monolithic zirconia crowns.

  14. Suppressing Nonradiative Recombination in Crown-Shaped Quantum Wells

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwangwook [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ju, Gunwu [Gwangju Institute of Science and Technology; Korea Institute of Science and Technology; Na, Byung Hoon [Samsung Advanced Institute of Technology; Hwang, Hyeong-Yong [Gwangju Institute of Science and Technology; Jho, Young-Dahl [Gwangju Institute of Science and Technology; Myoung, NoSoung [Gwangju Institute of Science and Technology; Yim, Sang-Youp [Gwangju Institute of Science and Technology; Kim, Hyung-jun [Korea Institute of Science and Technology; Lee, Yong Tak [Gwangju Institute of Science and Technology

    2018-02-06

    We examined the structural and optical properties of a crown-shaped quantum well (CSQW) to suppress nonradiative recombination. To reduce carrier loss in defect traps at the well/barrier interface, the CSQW was designed to concentrate carriers in the central region by tailoring the bandgap energy. Temperature-dependent photoluminescence measurements showed that the CSQW had a high activation energy and low potential fluctuation. In addition, the long carrier lifetime of the CSQW at high temperatures can be interpreted as indicating a decrease in carrier loss at defect traps.

  15. MULTISEASONAL TREE CROWN STRUCTURE MAPPING WITH POINT CLOUDS FROM OTS QUADROCOPTER SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. Hese

    2017-08-01

    Full Text Available OTF (Off The Shelf quadro copter systems provide a cost effective (below 2000 Euro, flexible and mobile platform for high resolution point cloud mapping. Various studies showed the full potential of these small and flexible platforms. Especially in very tight and complex 3D environments the automatic obstacle avoidance, low copter weight, long flight times and precise maneuvering are important advantages of these small OTS systems in comparison with larger octocopter systems. This study examines the potential of the DJI Phantom 4 pro series and the Phantom 3A series for within-stand and forest tree crown 3D point cloud mapping using both within stand oblique imaging in different altitude levels and data captured from a nadir perspective. On a test site in Brandenburg/Germany a beach crown was selected and measured with 3 different altitude levels in Point Of Interest (POI mode with oblique data capturing and deriving one nadir mosaic created with 85/85 % overlap using Drone Deploy automatic mapping software. Three different flight campaigns were performed, one in September 2016 (leaf-on, one in March 2017 (leaf-off and one in May 2017 (leaf-on to derive point clouds from different crown structure and phenological situations – covering the leaf-on and leafoff status of the tree crown. After height correction, the point clouds where used with GPS geo referencing to calculate voxel based densities on 50 × 10 × 10 cm voxel definitions using a topological network of chessboard image objects in 0,5 m height steps in an object based image processing environment. Comparison between leaf-off and leaf-on status was done on volume pixel definitions comparing the attributed point densities per volume and plotting the resulting values as a function of distance to the crown center. In the leaf-off status SFM (structure from motion algorithms clearly identified the central stem and also secondary branch systems. While the penetration into the

  16. Multiseasonal Tree Crown Structure Mapping with Point Clouds from OTS Quadrocopter Systems

    Science.gov (United States)

    Hese, S.; Behrendt, F.

    2017-08-01

    OTF (Off The Shelf) quadro copter systems provide a cost effective (below 2000 Euro), flexible and mobile platform for high resolution point cloud mapping. Various studies showed the full potential of these small and flexible platforms. Especially in very tight and complex 3D environments the automatic obstacle avoidance, low copter weight, long flight times and precise maneuvering are important advantages of these small OTS systems in comparison with larger octocopter systems. This study examines the potential of the DJI Phantom 4 pro series and the Phantom 3A series for within-stand and forest tree crown 3D point cloud mapping using both within stand oblique imaging in different altitude levels and data captured from a nadir perspective. On a test site in Brandenburg/Germany a beach crown was selected and measured with 3 different altitude levels in Point Of Interest (POI) mode with oblique data capturing and deriving one nadir mosaic created with 85/85 % overlap using Drone Deploy automatic mapping software. Three different flight campaigns were performed, one in September 2016 (leaf-on), one in March 2017 (leaf-off) and one in May 2017 (leaf-on) to derive point clouds from different crown structure and phenological situations - covering the leaf-on and leafoff status of the tree crown. After height correction, the point clouds where used with GPS geo referencing to calculate voxel based densities on 50 × 10 × 10 cm voxel definitions using a topological network of chessboard image objects in 0,5 m height steps in an object based image processing environment. Comparison between leaf-off and leaf-on status was done on volume pixel definitions comparing the attributed point densities per volume and plotting the resulting values as a function of distance to the crown center. In the leaf-off status SFM (structure from motion) algorithms clearly identified the central stem and also secondary branch systems. While the penetration into the crown

  17. Usurpation of a Crowned Lapwing Vanellus coronatus nest by ...

    African Journals Online (AJOL)

    I report an instance of usurpation of a Crowned Lapwing Vanellus coronatus nest by a pair of African Wattled Lapwings Vanellus senegalensis. The nest, which originally contained a single Crowned Lapwing egg, eventually contained an additional three Wattled Lapwing eggs, before it was predated. Although parents of ...

  18. Antioxidative effect of lipophilized caffeic acid in fish oil enriched mayonnaise and milk

    DEFF Research Database (Denmark)

    Alemán, Mercedes; Bou, Ricard; Guardiola, Francesc

    2015-01-01

    The antioxidative effect of lipophilized caffeic acid was assessed in two different fish oil enriched food products: mayonnaise and milk. In both emulsion systems, caffeic acid esterified with fatty alcohols of different chain lengths (C1–C20) were better antioxidants than the original phenolic c...

  19. Determination of the variability of both hydrophilic and lipophilic toxins in endemic wild bivalves and carnivorous gastropods from the southern part of Chile.

    Science.gov (United States)

    Zamorano, Ruben; Marín, Michelle; Cabrera, Fabiola; Figueroa, Diego; Contreras, Cristóbal; Barriga, Andrés; Lagos, Néstor; García, Carlos

    2013-01-01

    The aim of this study was to analyse and determine the composition of paralytic shellfish poisoning (PSP) toxins and lipophilic toxins in the Region of Aysén, Chile, in wild endemic mussels (Mytilus chilensis, Venus antiqua, Aulacomya ater, Choromytilus chorus, Tagelus dombeii and Gari solida) and in two endemic carnivorous molluscs species (Concholepas concholepas and Argobuccinum ranelliforme). PSP-toxin contents were determined by using HPLC with fluorescence detection, while lipophilic toxins were determined by using LC-MS/MS. Mean concentrations for the total of PSP toxins were in the range 55-2505 μg saxitoxin-equivalent/100 g. The two most contaminated samples for PSP toxicity were bivalve Gari solida and carnivorous Argobuccinum ranelliforme with 2505 ± 101 and 1850 ± 137 μg saxitoxin-equivalent/100 g, respectively (p < 0.05). The lipophilic toxins identified were okadaic acid, dinophysistoxin-1 (DTX-1), azaspiracid-1 (AZA-1), pectenotoxin-2 (PTX-2) and yessotoxins (YTX). All analysed molluscs contained lipophilic toxins at levels ranging from 56 ± 4.8 to 156.1 ± 8.2 μg of okadaic acid-equivalent/kg shellfish together with YTX at levels ranging from 1.0 ± 0.1 to 18 ± 0.9 μg of YTX-equivalent/kg shellfish and AZA at levels ranging from 3.6 ± 0.2 to 31 ± 2.1 μg of AZA-equivalent/kg shellfish. Furthermore, different bivalves and gastropods differ in their capacity of retention of lipophilic toxins, as shown by the determination of their respective lipophilic toxins levels. In all the evaluated species, the presence of lipophilic toxins associated with biotransformation in molluscs and carnivorous gastropods was not identified, in contrast to the identification of PSP toxins, where the profiles identified in the different species are directly related to biotransformation processes. Thus, this study provides evidence that the concentration of toxins in the food intake of the evaluated species (Bivalvia and Gastropoda class) determines the degree of

  20. The recovery of gold and pyrite from a residue dump at Crown Mines

    International Nuclear Information System (INIS)

    Keleghan, W.

    1976-01-01

    The application of ore-dressing methods to a residue dump at Crown Mines has been examined. The use of either single-stage or double-stage gravity concentration is advocated for the recovery of the gold. Flotation and wet high-intensity magnetic separation (WHIMS) are not recommended. The two-stage gravity process facilitates the recovery of most of the pyrite in the residue (over 70 per cent) at commercial grade (40 per cent sulphur), but sacrifices some of the gold obtainable by a single-stage operation. There is little prospect of the commercial recovery of uranium from the dump at Crown Mines

  1. Failure analysis of various monolithic posterior aesthetic dental crowns using finite element method

    Science.gov (United States)

    Porojan, Liliana; Topală, Florin

    2017-08-01

    The aim of the study was to assess the effect of material stiffness and load on the biomechanical performance of the monolithic full-coverage posterior aesthetic dental crowns using finite element analysis. Three restorative materials for monolithic dental crowns were selected for the study: zirconia; lithium disilicate glass-ceramic, and resin-based composite. Stresses were calculated in the crowns for all materials and in the teeth structures, under different load values. The experiments show that dental crowns made from all this new aesthetic materials processed by CAD/CAM technologies would be indicated as monolithic dental crowns for posterior areas.

  2. Correlation of lipophilicity with mosquito larvicidal and repellent activities of novel trifluoromethylphenyl amides

    Science.gov (United States)

    For a chemical to have a biological impact on an organism, the molecules must be capable of being transported across the membranes of cells. Lipophilic insecticides that can pass through lipid bilayers and penetrate the insect cuticle can lead to rapid intoxication or mortality by acting on the nerv...

  3. Genome-Wide Association Mapping of Crown Rust Resistance in Oat Elite Germplasm.

    Science.gov (United States)

    Klos, Kathy Esvelt; Yimer, Belayneh A; Babiker, Ebrahiem M; Beattie, Aaron D; Bonman, J Michael; Carson, Martin L; Chong, James; Harrison, Stephen A; Ibrahim, Amir M H; Kolb, Frederic L; McCartney, Curt A; McMullen, Michael; Fetch, Jennifer Mitchell; Mohammadi, Mohsen; Murphy, J Paul; Tinker, Nicholas A

    2017-07-01

    Oat crown rust, caused by f. sp. , is a major constraint to oat ( L.) production in many parts of the world. In this first comprehensive multienvironment genome-wide association map of oat crown rust, we used 2972 single-nucleotide polymorphisms (SNPs) genotyped on 631 oat lines for association mapping of quantitative trait loci (QTL). Seedling reaction to crown rust in these lines was assessed as infection type (IT) with each of 10 crown rust isolates. Adult plant reaction was assessed in the field in a total of 10 location-years as percentage severity (SV) and as infection reaction (IR) in a 0-to-1 scale. Overall, 29 SNPs on 12 linkage groups were predictive of crown rust reaction in at least one experiment at a genome-wide level of statistical significance. The QTL identified here include those in regions previously shown to be linked with seedling resistance genes , , , , , and and also with adult-plant resistance and adaptation-related QTL. In addition, QTL on linkage groups Mrg03, Mrg08, and Mrg23 were identified in regions not previously associated with crown rust resistance. Evaluation of marker genotypes in a set of crown rust differential lines supported as the identity of . The SNPs with rare alleles associated with lower disease scores may be suitable for use in marker-assisted selection of oat lines for crown rust resistance. Copyright © 2017 Crop Science Society of America.

  4. Zirconia crowns for rehabilitation of decayed primary incisors: an esthetic alternative.

    Science.gov (United States)

    Ashima, G; Sarabjot, K Bhatia; Gauba, K; Mittal, H C

    2014-01-01

    Esthetic management of extensively decayed primary maxillary anterior teeth requiring full coronal coverage restoration is usually challenging to the pediatric dentists especially in very young children. Many esthetic options have been tried over the years each having its own advantages, disadvantages and associated technical, functional or esthetic limitations. Zirconia crowns have provided a treatment alternative to address the esthetic concerns and ease of placement of extra-coronal restorations on primary anterior teeth. The present article presents a case where grossly decayed maxillary primary incisors were restored esthetically and functionally with ready made zirconia crowns (ZIRKIZ, HASS Corp; Korea). After endodontic treatment the decayed teeth were restored with zirconia crowns. Over a 30 months period, the crowns have demonstrated good retention and esthetic results. Dealing with esthetic needs in children with extensive loss of tooth structure, using Zirconia crowns would be practical and successful. The treatment described is simple and effective and represents a promising alternative for rehabilitation of decayed primary teeth.

  5. Application of terrestrial laser scanning for measuring tree crown structures

    International Nuclear Information System (INIS)

    Pretzsch, H.; Seifert, S.; Huang, P.

    2011-01-01

    This paper addresses the potential of terrestrial laser scanning (TLS) for describing and modelling of tree crown structure and dynamics. We first present a general approach for the metabolic and structural scaling of tree crowns. Out of this approach we emphasize those normalization and scaling parameters which become accessible by TLS. For example we show how the individual tree leaf area index, convex hull, and its space-filling by leaves can be extracted out of laser scan data. This contributes to a theoretical and empirical substantiation of crown structure models which were missing so far for e.g. quantification of structural and species diversity in forest stands, inventory of crown biomass, species detection by remote sensing, and understanding of self- and alien-thinning in pure and mixed stands. Up to now works on this topic delivered a rather scattered empirical knowledge mainly by single inventories of trees and stands. In contrast, we recommend to start with a model approach, and to complete existing data with repeated TLS inventories in order to come to a consistent and theoretically based model of tree crowns. (author) [de

  6. Effectiveness of water-air and octanol-air partition coefficients to predict lipophilic flavor release behavior from O/W emulsions.

    Science.gov (United States)

    Tamaru, Shunji; Igura, Noriyuki; Shimoda, Mitsuya

    2018-01-15

    Flavor release from food matrices depends on the partition of volatile flavor compounds between the food matrix and the vapor phase. Thus, we herein investigated the relationship between released flavor concentrations and three different partition coefficients, namely octanol-water, octanol-air, and water-air, which represented the oil, water, and air phases present in emulsions. Limonene, 2-methylpyrazine, nonanal, benzaldehyde, ethyl benzoate, α-terpineol, benzyl alcohol, and octanoic acid were employed. The released concentrations of these flavor compounds from oil-in-water (O/W) emulsions were measured under equilibrium using static headspace gas chromatography. The results indicated that water-air and octanol-air partition coefficients correlated with the logarithms of the released concentrations in the headspace for highly lipophilic flavor compounds. Moreover, the same tendency was observed over various oil volume ratios in the emulsions. Our findings therefore suggest that octanol-air and water-air partition coefficients can be used to predict the released concentration of lipophilic flavor compounds from O/W emulsions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. A Comparative Study of Molecular Structure, pKa, Lipophilicity, Solubility, Absorption and Polar Surface Area of Some Antiplatelet Drugs

    Directory of Open Access Journals (Sweden)

    Milan Remko

    2016-03-01

    Full Text Available Theoretical chemistry methods have been used to study the molecular properties of antiplatelet agents (ticlopidine, clopidogrel, prasugrel, elinogrel, ticagrelor and cangrelor and several thiol-containing active metabolites. The geometries and energies of most stable conformers of these drugs have been computed at the Becke3LYP/6-311++G(d,p level of density functional theory. Computed dissociation constants show that the active metabolites of prodrugs (ticlopidine, clopidogrel and prasugrel and drugs elinogrel and cangrelor are completely ionized at pH 7.4. Both ticagrelor and its active metabolite are present at pH = 7.4 in neutral undissociated form. The thienopyridine prodrugs ticlopidine, clopidogrel and prasugrel are lipophilic and insoluble in water. Their lipophilicity is very high (about 2.5–3.5 logP values. The polar surface area, with regard to the structurally-heterogeneous character of these antiplatelet drugs, is from very large interval of values of 3–255 Å2. Thienopyridine prodrugs, like ticlopidine, clopidogrel and prasugrel, with the lowest polar surface area (PSA values, exhibit the largest absorption. A high value of polar surface area (PSA of cangrelor (255 Å2 results in substantial worsening of the absorption in comparison with thienopyridine drugs.

  8. Lipophilic versus hydrophilic statin therapy for heart failure: a protocol for an adjusted indirect comparison meta-analysis

    Science.gov (United States)

    2013-01-01

    Background Statins are known to reduce cardiovascular morbidity and mortality in primary and secondary prevention studies. Subsequently, a number of nonrandomised studies have shown statins improve clinical outcomes in patients with heart failure (HF). Small randomised controlled trials (RCT) also show improved cardiac function, reduced inflammation and mortality with statins in HF. However, the findings of two large RCTs do not support the evidence provided by previous studies and suggest statins lack beneficial effects in HF. Two meta-analyses have shown statins do not improve survival, whereas two others showed improved cardiac function and reduced inflammation in HF. It appears lipophilic statins produce better survival and other outcome benefits compared to hydrophilic statins. But the two types have not been compared in direct comparison trials in HF. Methods/design We will conduct a systematic review and meta-analysis of lipophilic and hydrophilic statin therapy in patients with HF. Our objectives are: 1. To determine the effects of lipophilic statins on (1) mortality, (2) hospitalisation for worsening HF, (3) cardiac function and (4) inflammation. 2. To determine the effects of hydrophilic statins on (1) mortality, (2) hospitalisation for worsening HF, (3) cardiac function and (4) inflammation. 3. To compare the efficacy of lipophilic and hydrophilic statins on HF outcomes with an adjusted indirect comparison meta-analysis. We will conduct an electronic search of databases for RCTs that evaluate statins in patients with HF. The reference lists of all identified studies will be reviewed. Two independent reviewers will conduct the search. The inclusion criteria include: 1. RCTs comparing statins with placebo or no statin in patients with symptomatic HF. 2. RCTs that employed the intention-to-treat (ITT) principle in data analysis. 3. Symptomatic HF patients of all aetiologies and on standard treatment. 4. Statin of any dose as intervention. 5. Placebo or no

  9. Induced mutations for tolerance of oats to crown rust

    International Nuclear Information System (INIS)

    Simons, M.D.; Frey, K.J.

    1977-01-01

    Seeds of three oat (Avena sativa and A. abyssinica) strains were treated with ethyl methanesulphonate (EMS), and crown rust (caused by Puccinia coronata var. avenae) tolerance ratios of M 5 -derived lines were compared with untreated checks. Tolerance ratios of mutant lines tended to be distributed in both plus and minus directions. No mutant oat line had a significant increase in grain yield, but many showed significantly depressed yields. With C.I. 6665, only five of 130 mutagen-derived lines were not significantly below the check for grain yield; one of these had significantly improved tolerance. Re-treatment of selected strains from a previous EMS treatment (original cultivar was Clintland-60) gave one M 5 -derived oat line (of 100 tested) that was equal to Clintland-60 in grain yield and sustained no damage from crown rust (i.e. it had a tolerance ratio of 100). EMS treatment of the highly susceptible tetraploid C.I. 2110 resulted in both significantly increased and reduced tolerance. (author)

  10. Uniform versus asymmetric shading mediates crown recession in conifers.

    Directory of Open Access Journals (Sweden)

    Amanda L Schoonmaker

    Full Text Available In this study we explore the impact of asymmetrical vs. uniform crown shading on the mortality and growth of upper and lower branches within tree crowns, for two conifer species: shade intolerant lodgepole pine (Pinus contorta and shade tolerant white spruce (Picea glauca. We also explore xylem hydraulics, foliar nutrition, and carbohydrate status as drivers for growth and expansion of the lower and upper branches in various types of shading. This study was conducted over a two-year period across 10 regenerating forest sites dominated by lodgepole pine and white spruce, in the lower foothills of Alberta, Canada. Trees were assigned to one of four shading treatments: (1, complete uniform shading of the entire tree, (2 light asymmetric shading where the lower 1/4-1/3 of the tree crown was shaded, (3 heavy asymmetric shading as in (2 except with greater light reduction and (4 control in which no artificial shading occurred and most of the entire crown was exposed to full light. Asymmetrical shading of only the lower crown had a larger negative impact on the bud expansion and growth than did uniform shading, and the effect was stronger in pine relative to spruce. In addition, lower branches in pine also had lower carbon reserves, and reduced xylem-area specific conductivity compared to spruce. For both species, but particularly the pine, the needles of lower branches tended to store less C than upper branches in the asymmetric shade, which could suggest a movement of reserves away from the lower branches. The implications of these findings correspond with the inherent shade tolerance and self-pruning behavior of these conifers and supports a carbon based mechanism for branch mortality--mediated by an asymmetry in light exposure of the crown.

  11. Retention of metal-ceramic crowns with contemporary dental cements.

    Science.gov (United States)

    Johnson, Glen H; Lepe, Xavier; Zhang, Hai; Wataha, John C

    2009-09-01

    New types of crown and bridge cement are in use by practitioners, and independent studies are needed to assess their effectiveness. The authors conducted a study in three parts (study A, study B, and study C) and to determine how well these new cements retain metal-ceramic crowns. The authors prepared teeth with a 20-degree taper and a 4-millimeter length. They cast high-noble metal-ceramic copings, then fitted and cemented them with a force of 196 newtons. The types of cements they used were zinc phosphate, resin-modified glass ionomer, conventional resin and self-adhesive modified resin. They thermally cycled the cemented copings, then removed them. They recorded the removal force and calculated the stress of dislodgment by using the surface area of each preparation. They used a single-factor analysis of variance to analyze the data (alpha = .05). The mean stresses necessary to remove crowns, in megapascals, were 8.0 for RelyX Luting (3M ESPE, St. Paul, Minn.), 7.3 for RelyX Unicem (3M ESPE), 5.7 for Panavia F (Kuraray America, New York) and 4.0 for Fuji Plus (GC America, Alsip, Ill.) in study A; 8.1 for RelyX Luting, 2.6 for RelyX Luting Plus (3M ESPE) and 2.8 for Fuji CEM (GC America) in study B; and 4.9 for Maxcem (Kerr, Orange, Calif.), 4.0 for BisCem (Bisco, Schaumburg, Ill.), 3.7 for RelyX Unicem Clicker (3M ESPE), 2.9 for iCEM (Heraeus Kulzer, Armonk, N.Y.) and 2.3 for Fleck's Zinc Cement (Keystone Industries, Cherry Hill, N.J.) in study C. Powder-liquid versions of new cements were significantly more retentive than were paste-paste versions of the same cements. The mean value of crown removal stress for the new self-adhesive modified-resin cements varied appreciably among the four cements tested. All cements retained castings as well as or better than did zinc phosphate cement. Powder-liquid versions of cements, although less convenient to mix, may be a better clinical choice when crown retention is an issue. All cements tested will retain castings

  12. Optimizing solubility and permeability of a biopharmaceutics classification system (BCS) class 4 antibiotic drug using lipophilic fragments disturbing the crystal lattice.

    Science.gov (United States)

    Tehler, Ulrika; Fagerberg, Jonas H; Svensson, Richard; Larhed, Mats; Artursson, Per; Bergström, Christel A S

    2013-03-28

    Esterification was used to simultaneously increase solubility and permeability of ciprofloxacin, a biopharmaceutics classification system (BCS) class 4 drug (low solubility/low permeability) with solid-state limited solubility. Molecular flexibility was increased to disturb the crystal lattice, lower the melting point, and thereby improve the solubility, whereas lipophilicity was increased to enhance the intestinal permeability. These structural changes resulted in BCS class 1 analogues (high solubility/high permeability) emphasizing that simple medicinal chemistry may improve both these properties.

  13. Absorption of Nickel, Chromium, and Iron by the Root Surface of Primary Molars Covered with Stainless Steel Crowns

    Directory of Open Access Journals (Sweden)

    David Keinan

    2010-01-01

    Full Text Available Objective. The purpose of this study was to analyze the absorption of metal ions released from stainless steel crowns by root surface of primary molars. Study Design. Laboratory research: The study included 34 primary molars, exfoliated or extracted during routine dental treatment. 17 molars were covered with stainless-steel crowns for more than two years and compared to 17 intact primary molars. Chemical content of the mesial or distal root surface, 1 mm apically to the crown or the cemento-enamel junction (CEJ, was analyzed. An energy dispersive X-ray spectrometer (EDS was used for chemical analysis. Results. Higher amounts of nickel, chromium, and iron (5-6 times were found in the cementum of molars covered with stainless-steel crowns compared to intact molars. The differences between groups were highly significant (<.001. Significance. Stainless-steel crowns release nickel, chromium, and iron in oral environment, and the ions are absorbed by the primary molars roots. The additional burden of allergenic metals should be reduced if possible.

  14. Three-dimensional numerical simulation of crown spike due to coupling effect between bubbles and free surface

    International Nuclear Information System (INIS)

    Han Rui; Zhang A-Man; Li Shuai

    2014-01-01

    The motion of gas bubbles beneath a free surface will lead to a spike of fluid on the free surface. The distance of the bubbles to the free surface is the key factor to different phenomena. When the inception distance varies in some range, crown phenomenon would happen after the impact of weak buoyancy bubbles, so this kind of spike is defined as crown spike in the present paper. Based on potential flow theory, a three-dimensional numerical model is established to simulate the motion of the free-surface spike generated by one bubble or a horizontal line of two in-phase bubbles. After the downward jet formed near the end of the collapse phase, the simulation of the free surface is performed to study the crown spike without regard to the toroidal bubble's effect. Calculations about the interaction between one bubble and free surface agree well with the experimental results conducted with a high-speed camera, and relative error is within 15%. Crown spike in both single- and two-bubble cases are simulated numerically. Different features and laws of the motion of crown spike, depending on the bubble-boundary distances and the inter-bubble distances, have been investigated

  15. Supercritical Carbon Dioxide and Microwave-Assisted Extraction of Functional Lipophilic Compounds from Arthrospira platensis

    Directory of Open Access Journals (Sweden)

    Diego A. Esquivel-Hernández

    2016-05-01

    Full Text Available Arthrospira platensis biomass was used in order to obtain functional lipophilic compounds through green extraction technologies such as supercritical carbon dioxide fluid extraction (SFE and microwave-assisted extraction (MAE. The temperature (T factor was evaluated for MAE, while for SFE, pressure (P, temperature (T, and co-solvent (ethanol (CS were evaluated. The maximum extraction yield of the obtained oleoresin was (4.07% ± 0.14% and (4.27% ± 0.10% for SFE and MAE, respectively. Extracts were characterized by gas chromatography mass spectrometry (GC-MS and gas chromatography flame ionization detector (GC-FID. The maximum contents of functional lipophilic compounds in the SFE and MAE extracts were: for carotenoids 283 ± 0.10 μg/g and 629 ± 0.13 μg/g, respectively; for tocopherols 5.01 ± 0.05 μg/g and 2.46 ± 0.09 μg/g, respectively; and for fatty acids 34.76 ± 0.08 mg/g and 15.88 ± 0.06 mg/g, respectively. In conclusion, the SFE process at P 450 bar, T 60 °C and CS 53.33% of CO2 produced the highest yield of tocopherols, carotenoids and fatty acids. The MAE process at 400 W and 50 °C gives the best extracts in terms of tocopherols and carotenoids. For yield and fatty acids, the MAE process at 400 W and 70 °C produced the highest values. Both SFE and MAE showed to be suitable green extraction technologies for obtaining functional lipophilic compounds from Arthrospira platensis.

  16. Fracture load of different crown systems on zirconia implant abutments.

    Science.gov (United States)

    Albrecht, T; Kirsten, A; Kappert, H F; Fischer, H

    2011-03-01

    The purpose of this study was to evaluate the fracture load of single zirconia abutment restorations using different veneering techniques and materials. The abutment restorations were divided into 6 groups with 20 samples each: test abutments (control group A), lithium disilicate ceramic crowns bonded on incisor abutments (group B), leucite ceramic crowns bonded on incisor abutments (group C), premolar abutments directly veneered with a fluor apatite ceramic (group D (layered) and group E (pressed)) and premolar abutments bonded with lithium disilicate ceramic crowns (group F). The fracture load of the restorations was evaluated using a universal testing machine. Half of each group was artificially aged (chewing simulation and thermocycling) before evaluating the fracture load with the exception of the test abutments. The fracture load of the test abutments was 705 ± 43N. Incisor abutments bonded with lithium disilicate or leucite ceramic crowns (groups B and C) showed fracture loads of about 580N. Premolar restorations directly veneered with fluor apatite ceramic (groups D and E) showed fracture loads of about 850N. Premolar restorations bonded with lithium disilicate ceramic crowns (group F) showed fracture loads of about 1850N. The artificial ageing showed no significant influence on the strength of the examined restorations. All ceramic crowns made of lithium disilicate glass-ceramic, adhesively bonded to premolar abutments showed the highest fracture loads in this study. However, all tested groups can withstand physiological bite forces. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. Telescopic crowns as attachments for implant supported restorations: a case series.

    Science.gov (United States)

    Hoffmann, Oliver; Beaumont, Christian; Tatakis, Dimitris N; Zafiropoulos, Gregory-George

    2006-01-01

    The use of dental implants to support mandibular or maxillary overdentures is a widely used treatment modality. Advantages are an increase in retention, an increase in chewing ability, and easy access for oral hygiene procedures. While telescopic and conical crowns have been used for decades to connect natural teeth to overdentures, not many cases have been reported in the literature of telescopic crowns placed on implants to support overdentures. This article describes 7 patients with overdentures supported by telescopic crowns who received 65 implants (ITI Straumann). The cases presented in this report have been in function for up to 4.5 years. During that time no adverse events were reported. The use of telescopic crowns as attachments for implant-supported overdentures may be a viable treatment option.

  18. Co-extraction of Strontium and Cesium by Dicyclohexano-18 Crown-6/25, 27-Bis(2- Propyloxy)Calix[4]-26, 28-Crown-6{sup ..}Cn-Octanol

    Energy Technology Data Exchange (ETDEWEB)

    Ye, W.L.; Wang, J.CH.; He, Q.G. [Institute of Nuclear and New Energy Technology, Tsinghua University, P.O. Box 1021, Beijing 102201 (China)

    2009-06-15

    The partitioning of {sup 90}Sr and {sup 137}Cs from high-level liquid waste(HLLW) is one of the important problems for the high-level waste volume reduction and the management of HLLW. The crown ether and calix-crown have the good extracting ability and selectivity to strontium and cesium respectively. Dicyclohexano-18Crown-6 (DCH18C-6) and 25, 27-Bis(2-propyloxy) Calix[4] -26, 28- Crown-6(IPR-C[4]C-6) were selected as extractants and n-octanol was selected as the common diluent to separate strontium and cesium from high-level liquid waste respectively in INET's Tsinghua University, China. But DCH18C- 6 and IPR-C[4]C-6 were used respectively in their processes to separate strontium and cesium. The strontium and cesium processes could be simplified if DCH18C-6 and IPR-C[4]C-6 processes are combined into one process to separate strontium and cesium together. In this paper, the co-extraction performance of strontium and cesium from nitric acid medium was studied by DCH18C-6 /IPR-C[4]C-6 and n-octanol as an diluent. Effects of extractant concentration, nitric concentration and temperature etc. on the extraction performance of strontium and cesium were studied. The results show that DCH18C-6 and IRP-C[4]C-6 in n-octanol has no synergistic extraction ability each other to strontium and cesium. Strontium and cesium were extracted independently by above two extractants. 0.1 mol/L DCH18C-6 and 0.025 mol/L /IPR-C[4]C-6 as extractants and n-octanol as a diluent were selected to separate strontium and cesium from HLLW. The cascade test in which was 10 stages for extraction, 2 stages for scrubbing and 8 stages for stripping was carried out on the miniature centrifugal contactor set. The results are the following: the removing ratios for strontium and cesium in the simulated HLLW were 98.93% and 99.93%, respectively; the stripping ratios of them were 99.80% and 99.79%, respectively. So the mixing extractants could be used to co-extract strontium and cesium from HLLW and

  19. Clinical assessment of class II resin-based composites versus preformed metal crowns performed on primary molars in patients at high risk of caries.

    Science.gov (United States)

    Alyahya, A; Khanum, A; Qudeimat, M

    2018-02-01

    To compare class II resin composite with preformed metal crowns (PMC) in the treatment of proximal dentinal caries in high caries-risk patients. The charts (270) of paediatric patients with proximal caries of their primary molars were reviewed. Success or failure of a procedure was assessed using the dental notes. Survival analysis was used to calculate the mean survival time (MST) for both procedures. The influence of variables on the mean survival time was investigated. A total of 593 class II resin composites and 243 PMCs were placed in patients ranging between 4-13 years of age. The failure percentage of class II resin composites was 22.6% with the majority having been due to recurrent caries, while the failure percentage of PMCs was 15.2% with the majority due to loss of the crown. There was no significant difference between the MST of class II resin composites and PMCs, 41.3 and 45.6 months respectively (p value = 0.06). In class II resin composites, mesial restorations were associated with lower MST compared to distal restorations (p-value composites and PMCs were comparable when performed on high caries-risk patients.

  20. Short-Term Prospective Clinical Evaluation of Monolithic and Partially Veneered Zirconia Single Crowns.

    Science.gov (United States)

    Bömicke, Wolfgang; Rammelsberg, Peter; Stober, Thomas; Schmitter, Marc

    2017-02-01

    The purpose of this study was to prospectively evaluate the short-term clinical performance and esthetics of monolithic and partially (i.e., facially) veneered zirconia single crowns (MZC and PZC, respectively). Between September 2011 and June 2013, 68 participants received 90 MZCs and 72 PZCs. Clinical study documentation was performed at crown cementation (baseline), at the 6-month follow-up, and then yearly thereafter using standardized report forms. Eight participants with 14 single crowns (eight MZCs and six PZCs) dropped out during clinical follow-up. Thus, 60 participants (28 male, mean age 62.5 ± 13.1 years) fitted with 82 MZCs and 66 PZCs were analyzed in February 2016 (Kaplan-Meier survival; mean observation time for the restorations 35.1 ± 6.3 months). Descriptive statistics were calculated for participants' and dentists' esthetic ratings on a numerical rating scale from 0 to 10 (0 = unacceptable color and shape; 10 = excellent color and shape). Complications were predominantly biological in nature. One PZC was affected by minor chipping. Cumulative 3-year failure-free survival was 98.5% (standard error (SE), 1.5%) for both MZCs and PZCs. Three-year cumulative complication-free survival (success) was 93.6% (SE 2.8%) for MZCs and 95.5% (SE 2.6%) for PZCs. Three-year cumulative fracture-free survival was 100% for MZCs and 98.5% (SE 1.5%) for PZCs. Crowns of both types were awarded high esthetic scores by participants and dentists. Monolithic and partially veneered zirconia crowns can be used clinically with excellent short-term survival and success and without compromising esthetic appearance. Longer-term follow-up is, however, desirable. During the observation time, both monolithic and partially veneered zirconia crowns showed an outstanding low technical complication rate: only one minor chipping and three losses of retention were observed. Additionally, esthetics was excellent. Based on these results the clinical use of this kind of

  1. Lung Surfactant Microbubbles Increase Lipophilic Drug Payload for Ultrasound-Targeted Delivery

    OpenAIRE

    Sirsi, Shashank R.; Fung, Chinpong; Garg, Sumit; Tianning, Mary Y.; Mountford, Paul A.; Borden, Mark A.

    2013-01-01

    The cavitation response of circulating microbubbles to targeted ultrasound can be used for noninvasive, site-specific delivery of shell-loaded materials. One challenge for microbubble-mediated delivery of lipophilic compounds is the limitation of drug loading into the microbubble shell, which is commonly a single phospholipid monolayer. In this study, we investigated the use of natural lung surfactant extract (Survanta?, Abbott Nutrition) as a microbubble shell material in order to improve dr...

  2. Effects of crown release on growth and quality of even-aged red maple stands

    Science.gov (United States)

    Terry F. Strong; Audra E. Hubbell; Adam H. Weise; Gayne G. Erdmann

    2006-01-01

    The effects of six crown-release treatments on growth and bole quality of 54 dominant, codominant, and intermediate red maples (Acer rubrum L.) were examined in an even-aged stand in upper Michigan. Treatments included an unreleased control, a single-tree and a two-tree crown release, and a full crown-to-crown release of 5, 10, and 15ft. Twenty-two...

  3. Complete separation of racemic p-boronophenylalanine by high performance liquid chromatography with crown ether-coated reversed-phase packings

    International Nuclear Information System (INIS)

    Yoshino, K.; Mieda, S.; Maruyama, T.; Mori, Y.; Mishima, Y.; Ichihashi, M.

    1992-01-01

    Since the L-form of p-boronophenylalanine (p-bpa) has been shown to be more efficiently incorporated into melanoma cells than racemic p-bpa separation of racemic p-bpa into its stereoisomers is an important subject. One of the preparative methods used to resolve racemic p-bpa involves the use of α-chymotrypsin. However, there has been a problem in that optical purity of resolved L- or D-p-bpa products was not easily determined. In this paper, the authors describe a method which can be used to confirm the optical purity of b-pba using high performance liquid chromatography (HPLC) with crown ether-coated reversed-phase packings

  4. [Comparative adaptation of crowns of selective laser melting and wax-lost-casting method].

    Science.gov (United States)

    Li, Guo-qiang; Shen, Qing-yi; Gao, Jian-hua; Wu, Xue-ying; Chen, Li; Dai, Wen-an

    2012-07-01

    To investigate the marginal adaptation of crowns fabricated by selective laser melting (SLM) and wax-lost-casting method, so as to provide an experimental basis for clinic. Co-Cr alloy full crown were fabricated by SLM and wax-lost-casting for 24 samples in each group. All crowns were cemented with zinc phosphate cement and cut along longitudinal axis by line cutting machine. The gap between crown tissue surface and die was measured by 6-point measuring method with scanning electron microscope (SEM). The marginal adaptation of crowns fabricated by SLM and wax-lost-casting were compared statistically. The gap between SLM crowns were (36.51 ± 2.94), (49.36 ± 3.31), (56.48 ± 3.35), (42.20 ± 3.60) µm, and wax-lost-casting crowns were (68.86 ± 5.41), (58.86 ± 6.10), (70.62 ± 5.79), (69.90 ± 6.00) µm. There were significant difference between two groups (P casting method and SLM method provide acceptable marginal adaptation in clinic, and the marginal adaptation of SLM is better than that of wax-lost-casting method.

  5. The general properties of water - nitrobenzene - crown - bis-1,2-dicarbollylcobaltate extraction systems

    International Nuclear Information System (INIS)

    Vanura, P.

    2003-01-01

    The extraction and stability constants in the system water - nitrobenzene have been collected and general rules valid for water - nitrobenzene - crown - bis-1,2-dicarbollylcobaltate extraction system have been found. The main principles are size compatibility of ion diameter and crown cavity diameters, the flexibility of crown, the basicity of crown and the steric factor of both the ligand and the extracted ion. The extraction in the system water - mineral acid or salt polyoxyethylene compound - bis-1,2-dicarbollylcobaltate - nitrobenzene is more complicated than can be expected from usually used ion diameter - crown cavity diameter compatibility principle. The other important factors are the basicity and the deformability of crown, steric aspect and the angles of bonds of extracted ion. The binuclear 'sandwich' complexes with H + ion and Sr 2+ or Ba 2+ ions have been proved for dibenzo-18-crown-6 (DB18C6). On the other hand, only SrL 2 and BaL 2 (L = 15C5) complexes are formed in nitrobenzene saturated with water. The addition of polyoxyethylene compound usually increases the distribution ratio of alkali earth metal ions and the selectivity of its mutual separation. (authors)

  6. Minor lipophilic compounds in edible insects

    Directory of Open Access Journals (Sweden)

    Monika Sabolová

    2016-07-01

    Full Text Available Contemporary society is faced with the question how to ensure suffiecient nutrition (quantity and quality for rapidly growing population. One solution can be consumption of edible insect, which can have very good nutritional value (dietary energy, protein, fatty acids, fibers, dietary minerals and vitamins composition. Some edible insects species, which contains a relatively large amount of fat, can have a potential to be a „good" (interesting, new source of minor lipophilic compounds such as sterols (cholesterol and phytosterols and tocopherols in our diet. For this reason, the objective of this work was to characterize the sterols and tocopherols composition of fat from larvae of edible insect Zophobas morio L. and Tenebrio mollitor L. Cholesterol and three phytosterols (campesterol, stigmasterol and β-sitosterol were reliably identified and quantified after hot saponification and derivatization by GC-MS. Other steroid compounds, including 5,6-trans-cholecalciferol were identified only according to the NIST library. Cholesterol was the predominant sterol in all analysed samples. Both types of larvae also contained high amount of phytosterols. Different region of origin had a no significant impact on sterols composition, while the effect of beetle genus was crucial. Tocopherols were analysed by reverse phase HPLC coupled with amperometric detection. Tocopherols content in mealworm larvae was lower than content in edible oils, but important from the nutritional point of view. Change of tocopherols composition was not observed during the storage under different conditions. Larvae of edible insect can be a potential good dietary source of cholesterol, but also vitamin D3 isomers, phytosterols and tocopherols.  

  7. Fit of interim crowns fabricated using photopolymer-jetting 3D printing.

    Science.gov (United States)

    Mai, Hang-Nga; Lee, Kyu-Bok; Lee, Du-Hyeong

    2017-08-01

    The fit of interim crowns fabricated using 3-dimensional (3D) printing is unknown. The purpose of this in vitro study was to evaluate the fit of interim crowns fabricated using photopolymer-jetting 3D printing and to compare it with that of milling and compression molding methods. Twelve study models were fabricated by making an impression of a metal master model of the mandibular first molar. On each study model, interim crowns (N=36) were fabricated using compression molding (molding group, n=12), milling (milling group, n=12), and 3D polymer-jetting methods. The crowns were prepared as follows: molding group, overimpression technique; milling group, a 5-axis dental milling machine; and polymer-jetting group using a 3D printer. The fit of interim crowns was evaluated in the proximal, marginal, internal axial, and internal occlusal regions by using the image-superimposition and silicone-replica techniques. The Mann-Whitney U test and Kruskal-Wallis tests were used to compare the results among groups (α=.05). Compared with the molding group, the milling and polymer-jetting groups showed more accurate results in the proximal and marginal regions (P3D printing significantly enhanced the fit of interim crowns, particularly in the occlusal region. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. [Chromatic study of all-ceramic crown--IPS Empress: difference of color by manufacturing technique and cements].

    Science.gov (United States)

    Hata, Utako; Sadamitsu, Kenichiro; Yamamura, Osamu; Kawauchi, Daisuke; Fujii, Teruhisa

    2004-12-01

    In recent years,aesthetic appearance and function are called for and all-ceramic crowns are spreading. By choosing an all-ceramic crown the problem of metal ceramics is avoided. There are difficulties of color tone reproducibility of cervical margin and darkness of gingival margin. We examined IPS Empress also in various all-ceramic crowns. IPS Empress has high permeability a ceramic ingot of various color tones and excellent color tone reproducibility of natural teeth. Generally a layering technique is used for an anterior tooth and the staining technique is used for a molar. However the details are unknown We examined how differences of manufacturing method and cement affect the color tone of all ceramics clinically. Two kinds of Empress crown were fabricated for a 27 year-old woman's upper left-side central incisors:the staining technique of IPS Empress and the layering technique of IPS Empress II. Various try-in pastes(transparent opaque white white and yellow) of VariolinkII of the IPS Empress System were used for cementing. Color was measured using a spectrophotometer CMS 35FS. The L*a*b* color system was used for showing a color. The right-side central incisors on the opposite side of the same name teeth were used for comparison. We analyzed the color difference (DeltaE* ab)with a natural tooth. Consequently when it had no cement of staining technique and was tranceparent small values were obtained. It is considered that the color tone can be adjusted by color cement. It is effective to use the staining technique for an anterior tooth crown depending on the case. The crown manufactured using the layering technique is not easily influenced by cement. The crown manufactured by the staining technique tends to be influenced by cement.

  9. Comparative in vitro evaluation of CAD/CAM vs conventional provisional crowns.

    Science.gov (United States)

    Abdullah, Adil Othman; Tsitrou, Effrosyni A; Pollington, Sarah

    2016-01-01

    This study compared the marginal gap, internal fit, fracture strength, and mode of fracture of CAD/CAM provisional crowns with that of direct provisional crowns. An upper right first premolar phantom tooth was prepared for full ceramic crown following tooth preparation guidelines. The materials tested were: VITA CAD-Temp®, Polyetheretherketone "PEEK", Telio CAD-Temp, and Protemp™4 (control group). The crowns were divided into four groups (n=10), Group1: VITA CAD-Temp®, Group 2: PEEK, Group 3: Telio CAD-Temp, and Group 4: Protemp™4. Each crown was investigated for marginal and internal fit, fracture strength, and mode of fracture. Statistical analysis was performed using GraphPad Prism software version 6.0. The average marginal gap was: VITA CAD-Temp® 60.61 (±9.99) µm, PEEK 46.75 (±8.26) µm, Telio CAD-Temp 56.10 (±5.65) µm, and Protemp™4 193.07(±35.96) µm (PCAD-Temp® 124.94 (±22.96) µm, PEEK 113.14 (±23.55) µm, Telio CAD-Temp 110.95 (±11.64) µm, and Protemp™4 143.48(±26.74) µm. The average fracture strength was: VITA CAD-Temp® 361.01 (±21.61) N, PEEK 802.23 (±111.29) N, Telio CAD-Temp 719.24 (±95.17) N, and Protemp™4 416.40 (±69.14) N. One-way ANOVA test showed a statistically significant difference for marginal gap, internal gap, and fracture strength between all groups (p0.05). CAD/CAM fabricated provisional crowns demonstrated superior fit and better strength than direct provisional crowns.

  10. Fracture strength testing of crowns made of CAD/CAM composite resins.

    Science.gov (United States)

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  11. [Effects of sub-micro emulsion composition on cellular disposition of incorporated lipophilic drug].

    Science.gov (United States)

    Sun, Xiao-Yi; Xiang, Zhi-Qiang; Wu, Shuo; Lv, Yuan-Yuan; Liang, Wen-Quan

    2013-09-01

    To investigate the effects of sub-micro emulsion composition on cellular uptake and disposition of incorporated lipophilic drug. Sub-micro emulsions containing 10 % oil, 1.2 % lecithin and 2.25 % glycerol were prepared, and the fluorescent agent coumarin 6 was used as a model drug. The effects of oil types, co-surfactants and cationic lipid on uptake and elimination kinetics of 6-coumarin in HeLa cells were studied. The uptake mechanism of sub-micro emulsions was further investigated. Oil type and Tweens had no influence on the cellular uptake. Modifications of surfactants with Span series increased the cellular influx, among which Span 20 with hydrophilic-lipophilic balance (HLB) value of 8.6 was the best enhancer. The intracellular drug level reached up to (46.09 ± 1.98)ng/μg protein which had significant difference with control group [(38.54 ± 0.34)ng/μg protein]. The positively charged emulsions significantly increased the uptake rate constant and elimination rate constant which were 4 times and 1.5 times of those in anionic groups, respectively. The uptake enhancement was also observed in cationic emulsions, cellular concentrations at plateau were (42.73 ± 0.84)ng/μg protein, which was about 3 times of that in anionic emulsions [(15.71 ± 0.74)ng/μg protein], when extracellular drug concentration kept at 100 ng/ml. Cationic emulsions delivered the payload mainly by direct drug transfer to contacted cells, while the negative ones depended on both drug passive diffusion and clathrin-mediated endocytosis of drug containing oil droplets which accounted for 20% of the intracellular drug. Interfacial characteristic of sub-micro emulsions such as co-surfactants HLB as well as zeta potentials can influence lipophilic drug both in cellular uptake and elimination.

  12. First Example of a Lipophilic Porphyrin-Cardanol Hybrid Embedded in a Cardanol-Based Micellar Nanodispersion

    Directory of Open Access Journals (Sweden)

    Giuseppe Vasapollo

    2012-10-01

    Full Text Available Cardanol is a natural and renewable organic raw material obtained as the major chemical component by vacuum distillation of cashew nut shell liquid. In this work a new sustainable procedure for producing cardanol-based micellar nanodispersions having an embedded lipophilic porphyrin itself peripherally functionalized with cardanol substituents (porphyrin-cardanol hybrid has been described for the first time. In particular, cardanol acts as the solvent of the cardanol hybrid porphyrin and cholesterol as well as being the main component of the nanodispersions. In this way a “green” micellar nanodispersion, in which a high percentage of the micellar system is derived from renewable “functional” molecules, has been produced.

  13. Radium separation through complexation by aqueous crown ethers and ion exchange or solvent extraction

    Energy Technology Data Exchange (ETDEWEB)

    Chiarizia, R.; Dietz, M.L.; Horwitz, E.P. [Argonne National Lab., IL (United States). Chemistry Div.; Burnett, W.C. [Florida State Univ., Tallahassee, FL (United States). Dept. of Oceanography

    1997-11-01

    The effect of three water-soluble, unsubstituted crown ethers (15-crown-5 (15C5), 18-crown-6 (18C6) and 21-crown-7 (21C7)) on the uptake of Ca, Sr, Ba and Ra cations by a sulfonic acid cation exchange resin, and on the extraction of the same cations by xylene solutions of dinonylnaphthalenesulfonic acid (HDNNS) from aqueous hydrochloric acid solutions has been investigated. The crown ethers enhance the sorption of the larger cations by the ion exchange resin, thereby improving the resin selectivity over calcium, a result of a synergistic interaction between the crown ether and the ionic functional groups of the resin. Similarly, the extraction of the larger alkaline earth cations into xylene by HDNNS is strongly synergized by the presence of the crown ethers in the aqueous phase. Promising results for intra-Group IIa cation separations have been obtained using each of the three crown ethers as the aqueous ligands and the sulfonic acid cation exchange resin. Even greater separation factors for the radium-calcium couple have been measured with the crown-ethers and HDNNS solutions in the solvent extraction mode. The application of the uptake and extraction results to the development of radium separation schemes is discussed and a possible flowchart for the determination of {sup 226}Ra/{sup 228}Ra in natural waters is presented.

  14. Influence of coping design on the cervical color of ceramic crowns.

    Science.gov (United States)

    Paniz, Gianluca; Kang, Ki-Ho; Kim, Yongjeong; Kumagai, Naota; Hirayama, Hiroshi

    2013-12-01

    The replication of natural teeth, especially with single-tooth restorations, represents a challenge. Similar to metal ceramic crowns, different designs of zirconia substructures have been suggested to improve the esthetic results of zirconia ceramic crowns. The purpose of the study was to analyze the color of the cervical portion of single zirconia ceramic crowns fabricated with different zirconia coping designs. The color, measured on the CIELAB color scale, of 3 different groups of restorations (n=10) fabricated with zirconia coping (Lava) and feldspathic porcelain (Noritake Super Porcelain) was analyzed with a spectrophotometer. Conventional zirconia crowns with zirconia facial margins were compared with ceramic crowns with porcelain facial margins and either a horizontal reduction of the zirconia coping (1.0 mm reduction) or an additional vertical reduction (1.0 mm additional reduction). The 3 groups, each with a different coping extension, were examined with a 1-way ANOVA and the Fisher exact test, and the differences of the groups were evaluated by applying ΔE thresholds (α=.05). The mean color difference among all the groups was not clinically significant (ΔEcolor differences were present between the 2 porcelain butt margin groups of crowns (ΔE=1.06, between group H and V). Increased differences were present between the zirconia margin group and the porcelain butt margin group (ΔE=2.54 between group C and H; ΔE=2.41 between group C and V). Lab* values were examined in all the groups of crowns to determine the clinical implications. Within the limitation of the study, no significant differences were present among the tested groups of crowns. Nevertheless, although some differences were present between the zirconia margin group and the porcelain butt margin group, reduced differences were present between the 2 different cutback designs. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights

  15. Biotic mortality factors affecting emerald ash borer (Agrilus planipennis) are highly dependent on life stage and host tree crown condition.

    Science.gov (United States)

    Jennings, D E; Duan, J J; Shrewsbury, P M

    2015-10-01

    Emerald ash borer (EAB), Agrilus planipennis, is a serious invasive forest pest in North America responsible for killing tens to hundreds of millions of ash trees since it was accidentally introduced in the 1990 s. Although host-plant resistance and natural enemies are known to be important sources of mortality for EAB in Asia, less is known about the importance of different sources of mortality at recently colonized sites in the invaded range of EAB, and how these relate to host tree crown condition. To further our understanding of EAB population dynamics, we used a large-scale field experiment and life-table analyses to quantify the fates of EAB larvae and the relative importance of different biotic mortality factors at 12 recently colonized sites in Maryland. We found that the fates of larvae were highly dependent on EAB life stage and host tree crown condition. In relatively healthy trees (i.e., with a low EAB infestation) and for early instars, host tree resistance was the most important mortality factor. Conversely, in more unhealthy trees (i.e., with a moderate to high EAB infestation) and for later instars, parasitism and predation were the major sources of mortality. Life-table analyses also indicated how the lack of sufficient levels of host tree resistance and natural enemies contribute to rapid population growth of EAB at recently colonized sites. Our findings provide further evidence of the mechanisms by which EAB has been able to successfully establish and spread in North America.

  16. Absorption infrared spectra of interaction products of cyclic polyethers 18-crown-6 and dibenzo-18-crown-6 with uranyl dinitrate hexahydrate

    International Nuclear Information System (INIS)

    Chumaevskij, N.A.; Belomestnykh, V.I.; Razgonyaeva, G.A.; Shabel'nik, K.S.; Afanas'eva, E.E.

    1988-01-01

    Using the method of IR spectroscopy it is established that during interaction of uranyl nitrate hexahydrate (UNH) with crown-ethers under investigation macrocycles adhere to UO 2 2+ via hydrogen bonds between water molecules and oxygen of polyethers. Interaction of UNH with the above-mentioned crowns leads to conformational rearrangement of cycles of polyethers and improvement of their symmetry, reflecting in noticeable simplification of IR spectra of interaction products as compared to spectra of initial cyclic polyethers

  17. Numerical modeling of laboratory-scale surface-to-crown fire transition

    Science.gov (United States)

    Castle, Drew Clayton

    Understanding the conditions leading to the transition of fire spread from a surface fuel to an elevated (crown) fuel is critical to effective fire risk assessment and management. Surface fires that successfully transition to crown fires can be very difficult to suppress, potentially leading to damages in the natural and built environments. This is relevant to chaparral shrub lands which are common throughout parts of the Southwest U.S. and represent a significant part of the wildland urban interface. The ability of the Wildland-Urban Interface Fire Dynamic Simulator (WFDS) to model surface-to-crown fire transition was evaluated through comparison to laboratory experiments. The WFDS model is being developed by the U.S. Forest Service (USFS) and the National Institute of Standards and Technology. The experiments were conducted at the USFS Forest Fire Laboratory in Riverside, California. The experiments measured the ignition of chamise (Adenostoma fasciculatum) crown fuel held above a surface fire spreading through excelsior fuel. Cases with different crown fuel bulk densities, crown fuel base heights, and imposed wind speeds were considered. Cold-flow simulations yielded wind speed profiles that closely matched the experimental measurements. Next, fire simulations with only the surface fuel were conducted to verify the rate of spread while factors such as substrate properties were varied. Finally, simulations with both a surface fuel and a crown fuel were completed. Examination of specific surface fire characteristics (rate of spread, flame angle, etc.) and the corresponding experimental surface fire behavior provided a basis for comparison of the factors most responsible for transition from a surface fire to the raised fuel ignition. The rate of spread was determined by tracking the flame in the Smokeview animations using a tool developed for tracking an actual flame in a video. WFDS simulations produced results in both surface fire spread and raised fuel bed

  18. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments.

    Science.gov (United States)

    Santing, Hendrik Jacob; Meijer, Henny J A; Raghoebar, Gerry M; Özcan, Mutlu

    2012-12-01

    Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. The objectives of this study were to evaluate the fracture strength of implant-supported composite resin crowns on PEEK and solid titanium temporary abutments, and to analyze the failure types. Three types of provisional abutments, RN synOcta Temporary Meso Abutment (PEEK; Straumann), RN synOcta Titanium Post for Temporary Restorations (Straumann), and Temporary Abutment Engaging NobRplRP (Nobel Biocare) were used, and provisional screw-retained crowns using composite resin (Solidex) were fabricated for four different locations in the maxilla. The specimens were tested in a universal testing machine at a crosshead speed of 1 mm/minute until fracture occurred. The failure types were analyzed and further categorized as irreparable (Type 1) or reparable (Type 2). No significant difference was found between different abutment types. Only for the position of the maxillary central incisor, composite resin crowns on PEEK temporary abutments showed significantly lower (p Provisional crowns on PEEK abutments showed similar fracture strength as titanium temporary abutments except for central incisors. Maxillary right central incisor composite resin crowns on PEEK temporary abutments fractured below the mean anterior masticatory loading forces reported to be approximately 206 N. © 2010 Wiley Periodicals, Inc.

  19. Crown-Level Tree Species Classification Using Integrated Airborne Hyperspectral and LIDAR Remote Sensing Data

    Science.gov (United States)

    Wang, Z.; Wu, J.; Wang, Y.; Kong, X.; Bao, H.; Ni, Y.; Ma, L.; Jin, J.

    2018-05-01

    Mapping tree species is essential for sustainable planning as well as to improve our understanding of the role of different trees as different ecological service. However, crown-level tree species automatic classification is a challenging task due to the spectral similarity among diversified tree species, fine-scale spatial variation, shadow, and underlying objects within a crown. Advanced remote sensing data such as airborne Light Detection and Ranging (LiDAR) and hyperspectral imagery offer a great potential opportunity to derive crown spectral, structure and canopy physiological information at the individual crown scale, which can be useful for mapping tree species. In this paper, an innovative approach was developed for tree species classification at the crown level. The method utilized LiDAR data for individual tree crown delineation and morphological structure extraction, and Compact Airborne Spectrographic Imager (CASI) hyperspectral imagery for pure crown-scale spectral extraction. Specifically, four steps were include: 1) A weighted mean filtering method was developed to improve the accuracy of the smoothed Canopy Height Model (CHM) derived from LiDAR data; 2) The marker-controlled watershed segmentation algorithm was, therefore, also employed to delineate the tree-level canopy from the CHM image in this study, and then individual tree height and tree crown were calculated according to the delineated crown; 3) Spectral features within 3 × 3 neighborhood regions centered on the treetops detected by the treetop detection algorithm were derived from the spectrally normalized CASI imagery; 4) The shape characteristics related to their crown diameters and heights were established, and different crown-level tree species were classified using the combination of spectral and shape characteristics. Analysis of results suggests that the developed classification strategy in this paper (OA = 85.12 %, Kc = 0.90) performed better than LiDAR-metrics method (OA = 79

  20. The solvent extraction of carrier-free 90Y from 90Sr with crown ethers

    International Nuclear Information System (INIS)

    Chuang, J.T.; Lo, J.G.

    1995-01-01

    A simple solvent extraction method has been developed for the separation of 90 Y from 90 Sr. Crown ether dissolved in chloroform was used as a selective reagent and organic picrate anion was chosen as a counter ion. The effect of various factors on the extraction equilibrium constant of strontium log K ex = 9.15 was obtained from the study of the distribution coefficient versus to crown ether concentration. The separation method was simple, resulted high purity (>99.9%) and quantitative yield, and took less than half an hour. (author) 27 refs.; 4 figs.; 4 tabs

  1. pH-Dependent dissolving nano- and microparticles for improved peroral delivery of a highly lipophilic compound in dogs.

    Science.gov (United States)

    De Jaeghere, F; Allémann, E; Cerny, R; Galli, B; Steulet, A F; Müller, I; Schütz, H; Doelker, E; Gurny, R

    2001-01-01

    RR01, a new highly lipophilic drug showing extremely low water solubility and poor oral bioavailability, has been incorporated into pH-dependent dissolving particles made of a poly(methacrylic acid-co-ethylacrylate) copolymer. The physicochemical properties of the particles were determined using laser-light-scattering techniques, scanning electron microscopy, high-performance liquid chromatography, and x-ray powder diffraction. Suspension of the free drug in a solution of hydroxypropylcellulose (reference formulation) and aqueous dispersions of pH-sensitive RR01-loaded nanoparticles or microparticles were administered orally to Beagle dogs according to a 2-block Latin square design (n = 6). Plasma samples were obtained over the course of 48 hours and analyzed by gas chromatography/mass spectrometry. The administration of the reference formulation resulted in a particularly high interindividual variability of pharmacokinetic parameters, with low exposure to compound RR01 (AUC0-48h of 6.5 microg x h/mL and coefficient of variation (CV) of 116%) and much higher Tmax, as compared to both pH-sensitive formulations. With respect to exposure and interindividual variability, nanoparticles were superior to microparticles (AUC0-48h of 27.1 microg x h/mL versus 17.7 microg x h/mL with CV of 19% and 40%, respectively), indicating that the particle size may play an important role in the absorption of compound RR01. The performance of pH-sensitive particles is attributed to their ability to release the drug selectively in the upper part of the intestine in a molecular or amorphous form. In conclusion, pH-dependent dissolving particles have a great potential as oral delivery systems for drugs with low water solubility and acceptable permeation properties.

  2. Investigating assumptions of crown archetypes for modelling LiDAR returns

    NARCIS (Netherlands)

    Calders, K.; Lewis, P.; Disney, M.; Verbesselt, J.; Herold, M.

    2013-01-01

    LiDAR has the potential to derive canopy structural information such as tree height and leaf area index (LAI), via models of the LiDAR signal. Such models often make assumptions regarding crown shape to simplify parameter retrieval and crown archetypes are typically assumed to contain a turbid

  3. Modelling initial mortality of Abies religiosa in a crown fire in Mexico

    Directory of Open Access Journals (Sweden)

    Salomé Temiño-Villota

    2016-04-01

    Full Text Available Aim of study: The objectives of this work were to determine which morphological and fire severity variables may help explain the mortality of adult Abies religiosa (Kunth Schltdl. & Cham., to model the probability of this species after being affected by crown fire, and to obtain more elements to classify the sacred fir in terms of fire resistance. This type of studies are relevant to estimate the impact of crown fires on the climax forests that forms this species.Area of study: The burned forest was located in the southern Mexico City, borough.Material and methods: Morphological variables and fire severity indicators were collected for 335 Abies religiosa trees burned by a mixed severity fire. Logistic regression was used to analyze data and develop models that best explained tree mortality.Main results: Survival was 26.9%. The models for height (p≤0.0001, diameter at breast height (p=0.0082, crown length (p≤0.0001 and crown base height (p≤0.0001 were significant, with a negative relationship between each one of these variables and probability of mortality. The significant severity variables were lethal scorch height (p≤0.0001 and crown kill (p≤ 0.0001, which have a direct relationship with probability of mortality.Highlights: This species is moderately fire-resistant. Crown kill ≥ 70% markedly increases mortality. Silvicultural activities such as pruning, thinning and fuel management can reduce the risk of crown fires.

  4. Modelling initial mortality of Abies religiosa in a crown fire in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Temiño-Villota, S.; Rodríguez-Trejo, D.A.; Molina Terrén, D.M.; Ryan, K.

    2016-07-01

    Aim of the study: The objectives of this work were to determine which morphological and fire severity variables may help explain the mortality of adult Abies religiosa (Kunth) Schltdl. & Cham., to model the probability of this species after being affected by crown fire, and to obtain more elements to classify the sacred fir in terms of fire resistance. This type of studies are relevant to estimate the impact of crown fires on the climax forests that forms this species. Area of study: The burned forest was located in the southern Mexico City, borough. Material and methods: Morphological variables and fire severity indicators were collected for 335 Abies religiosa trees burned by a mixed severity fire. Logistic regression was used to analyze data and develop models that best explained tree mortality. Main results: Survival was 26.9%. The models for height (p≤0.0001), diameter at breast height (p=0.0082), crown length (p≤0.0001) and crown base height (p≤0.0001) were significant, with a negative relationship between each one of these variables and probability of mortality. The significant severity variables were lethal scorch height (p≤0.0001) and crown kill (p≤ 0.0001), which have a direct relationship with probability of mortality. Highlights: This species is moderately fire-resistant. Crown kill ≥ 70% markedly increases mortality. Silvicultural activities such as pruning, thinning and fuel management can reduce the risk of crown fires. (Author)

  5. Unique case of a geminated supernumerary tooth with trifid crown

    International Nuclear Information System (INIS)

    Ather, Amber; Ather, Hunaiza; Sheth, Sanket Milan; Muliya, Vidya Saraswathi

    2012-01-01

    Gemination, a relatively uncommon dental anomaly, is characterized by its peculiar representation as a tooth with a bifid crown and a common root and root canal. It usually occurs in primary dentition. To come across gemination in a supernumerary tooth is a rare phenomenon. The purpose of this paper is to present a unique case of hyperdontia wherein gemination in an impacted supernumerary tooth resulted in a trifid crown unlike the usual bifid crown. The role of conventional radiographs as well as computed tomography, to accurately determine the morphology and spatial location, and to arrive at a diagnosis, is also emphasized in this paper.

  6. Treatment Recommendations for Single-Unit Crowns: Findings from The National Dental Practice-Based Research Network

    Science.gov (United States)

    McCracken, Michael S.; Louis, David R.; Litaker, Mark S.; Minyé, Helena M.; Mungia, Rahma; Gordan, Valeria V.; Marshall, Don G.; Gilbert, Gregg H.

    2016-01-01

    Background Objectives were to: (1) quantify practitioner variation in likelihood to recommend a crown; and (2) test whether certain dentist, practice, and clinical factors are significantly associated with this likelihood. Methods Dentists in the National Dental Practice-Based Research Network completed a questionnaire about indications for single-unit crowns. In four clinical scenarios, practitioners ranked their likelihood of recommending a single-unit crown. These responses were used to calculate a dentist-specific “Crown Factor” (CF; range 0–12). A higher score implies a higher likelihood to recommend a crown. Certain characteristics were tested for statistically significant associations with the CF. Results 1,777 of 2,132 eligible dentists responded (83%). Practitioners were most likely to recommend crowns for teeth that were fractured, cracked, endodontically-treated, or had a broken restoration. Practitioners overwhelmingly recommended crowns for posterior teeth treated endodontically (94%). Practice owners, Southwest practitioners, and practitioners with a balanced work load were more likely to recommend crowns, as were practitioners who use optical scanners for digital impressions. Conclusions There is substantial variation in the likelihood of recommending a crown. While consensus exists in some areas (posterior endodontic treatment), variation dominates in others (size of an existing restoration). Recommendations varied by type of practice, network region, practice busyness, patient insurance status, and use of optical scanners. Practical Implications Recommendations for crowns may be influenced by factors unrelated to tooth and patient variables. A concern for tooth fracture -- whether from endodontic treatment, fractured teeth, or large restorations -- prompted many clinicians to recommend crowns. PMID:27492046

  7. Stress and Reliability Analysis of a Metal-Ceramic Dental Crown

    Science.gov (United States)

    Anusavice, Kenneth J; Sokolowski, Todd M.; Hojjatie, Barry; Nemeth, Noel N.

    1996-01-01

    Interaction of mechanical and thermal stresses with the flaws and microcracks within the ceramic region of metal-ceramic dental crowns can result in catastrophic or delayed failure of these restorations. The objective of this study was to determine the combined influence of induced functional stresses and pre-existing flaws and microcracks on the time-dependent probability of failure of a metal-ceramic molar crown. A three-dimensional finite element model of a porcelain fused-to-metal (PFM) molar crown was developed using the ANSYS finite element program. The crown consisted of a body porcelain, opaque porcelain, and a metal substrate. The model had a 300 Newton load applied perpendicular to one cusp, a load of 30ON applied at 30 degrees from the perpendicular load case, directed toward the center, and a 600 Newton vertical load. Ceramic specimens were subjected to a biaxial flexure test and the load-to-failure of each specimen was measured. The results of the finite element stress analysis and the flexure tests were incorporated in the NASA developed CARES/LIFE program to determine the Weibull and fatigue parameters and time-dependent fracture reliability of the PFM crown. CARES/LIFE calculates the time-dependent reliability of monolithic ceramic components subjected to thermomechanical and/Or proof test loading. This program is an extension of the CARES (Ceramics Analysis and Reliability Evaluation of Structures) computer program.

  8. Biology and control of the raspberry crown borer (Lepidoptera: Sesiidae).

    Science.gov (United States)

    McKern, Jacquelyn A; Johnson, Donn T; Lewis, Barbara A

    2007-04-01

    This study explored the biology of raspberry crown borer, Pennisetia marginata (Harris) (Lepidoptera: Sesiidae), in Arkansas and the optimum timing for insecticide and nematode applications. The duration of P. marginata's life cycle was observed to be 1 yr in Arkansas. Insecticide trials revealed that bifenthrin, chlorpyrifos, imidacloprid, metaflumizone, and metofluthrin efficacy were comparable with that of azinphosmethyl, the only labeled insecticide for P. marginata in brambles until 2005. Applications on 23 October 2003 for plots treated with bifenthrin, chlorpyrifos, and azinphosmethyl resulted in >88% reduction in larvae per crown. Applications on 3 November 2004 of metaflumizone, metofluthrin, and bifenthrin resulted in >89% reduction in larvae per crown. Applications on 7 April 2005 for metofluthrin, imidacloprid, bifenthrin, metaflumizone, and benzoylphenyl urea resulted in >64% reduction in the number of larvae per crown. Applications on 6 May 2004 did not reduce larval numbers. The optimum timing for treatments was found to be between October and early April, before the larvae tunneled into the crowns of plants. Applying bifenthrin with as little as 468 liters water/ha (50 gal/acre) was found to be as effective against larvae as higher volumes of spray. Nematode applications were less successful than insecticides. Nematode applications of Steinernemafeltiae, Steinernema carpocapsae, and Heterorhabditis bacteriophora reduced larvae counts per plant by 46, 53, and 33%, respectively.

  9. Carotenoids, Tocopherols and Antioxidant Activity of Lipophilic Extracts from Sea Buckthorn Berries (Hippophae rhamnoides, Apricot Pulp and Apricot Kernel (Prunus armeniaca

    Directory of Open Access Journals (Sweden)

    Elena Andreea Pop

    2015-11-01

    Full Text Available A healthy human diet requires the daily consumption of fruits and vegetables rich in bioactive compounds. Sea buckthorn berries (Hippophae rhamnoides L. and apricot fruits (Prunus armeniaca L. are cultivated and appreciated in Romania both as fresh fruits and as derived products. Characterized by a complex chemical composition, sea buckthorn is rich in unsaturated lipids, carotenoids and tocopherols. Except for β-carotene content, less is known about other lipophilic compounds in apricot fruits. The aim of this paper was to separate and quantify the individual carotenoids, tocopherols and tocotrienols in sea buckthorn, apricot pulp and kernels and also to determine the antioxidant activity of the lipophilic extracts using the TEAC  method.  Chemical characterization of lipophilic extract was performed by HPLC with PDA and fluorescence detection. The total carotenoid content was 17.19±1.4 mg/100g F.W. in sea buckthorn; 3.51±0.25 mg/100g F.W. in apricot fruits and 0.58±0.04 mg/100 g F.W. in apricot kernels. The major carotenoids in sea buckthorn were β-carotene, zeaxanthin and β-cryptoxanthin esters. Apricots fruits are rich in β-carotene and its geometric isomers while in kernels we could properly identified only lycopene. The α-tocopherol concentration was higher in sea buckthorn (46 mg/kg than in apricot fruits (1.09 mg/kg while apricot kernel contain large amounts of γ-tocopherol (111 mg/kg. Sea buckthorn fruits showed the highest antioxidant capacity, correlated with a high content of both tocopherols and carotenoids.

  10. Applicability of non-destructive substitutes for leaf area in different stands of Norway spruce (Picea abies L. Karst.) focusing on traditional forest crown measures

    Science.gov (United States)

    Laubhann, Daniel; Eckmüllner, Otto; Sterba, Hubert

    2010-01-01

    Since individual tree leaf area is an important measure for productivity as well as for site occupancy, it is of high interest in many studies about forest growth. The exact determination of leaf area is nearly impossible. Thus, a common way to get information about leaf area is to use substitutes. These substitutes are often variables which are collected in a destructive way which is not feasible for long term studies. Therefore, this study aimed at testing the applicability of using substitutes for leaf area which could be collected in a non-destructive way, namely crown surface area and crown projection area. In 8 stands of Norway spruce (Picea abies L. Karst.), divided into three age classes and two thinning treatments, a total of 156 trees were felled in order to test the relationship between leaf area and crown surface area and crown projection area, respectively. Individual tree leaf area of the felled sample trees was estimated by 3P-branch sampling with an accuracy of ±10%. Crown projection area and crown surface area were compared with other, more commonly used, but destructive predictors of leaf area, namely sapwood area at different heights on the bole. Our investigations confirmed findings of several studies that sapwood area is the most precise measure for leaf area because of the high correlation between sapwood area and the leaf area. But behind sapwood area at crown base and sapwood area at three tenth of the tree height the predictive ability of crown surface area was ranked third and even better than that of sapwood area at breast height (R2 = 0.656 compared with 0.600). Within the stands leaf area is proportional to crown surface area. Using the pooled data of all stands a mixed model approach showed that additionally to crown surface area dominant height and diameter at breast height (dbh) improved the leaf area estimates. Thus, taking dominant height and dbh into account, crown surface area can be recommended for estimating the leaf area of

  11. Applicability of non-destructive substitutes for leaf area in different stands of Norway spruce (Picea abies L. Karst.) focusing on traditional forest crown measures.

    Science.gov (United States)

    Laubhann, Daniel; Eckmüllner, Otto; Sterba, Hubert

    2010-09-30

    Since individual tree leaf area is an important measure for productivity as well as for site occupancy, it is of high interest in many studies about forest growth. The exact determination of leaf area is nearly impossible. Thus, a common way to get information about leaf area is to use substitutes. These substitutes are often variables which are collected in a destructive way which is not feasible for long term studies. Therefore, this study aimed at testing the applicability of using substitutes for leaf area which could be collected in a non-destructive way, namely crown surface area and crown projection area. In 8 stands of Norway spruce (Picea abies L. Karst.), divided into three age classes and two thinning treatments, a total of 156 trees were felled in order to test the relationship between leaf area and crown surface area and crown projection area, respectively. Individual tree leaf area of the felled sample trees was estimated by 3P-branch sampling with an accuracy of ±10%. Crown projection area and crown surface area were compared with other, more commonly used, but destructive predictors of leaf area, namely sapwood area at different heights on the bole. Our investigations confirmed findings of several studies that sapwood area is the most precise measure for leaf area because of the high correlation between sapwood area and the leaf area. But behind sapwood area at crown base and sapwood area at three tenth of the tree height the predictive ability of crown surface area was ranked third and even better than that of sapwood area at breast height (R(2) = 0.656 compared with 0.600). Within the stands leaf area is proportional to crown surface area. Using the pooled data of all stands a mixed model approach showed that additionally to crown surface area dominant height and diameter at breast height (dbh) improved the leaf area estimates. Thus, taking dominant height and dbh into account, crown surface area can be recommended for estimating the leaf area

  12. The aesthetic treatment for anterior teeth with lost crown by endorestoration

    Directory of Open Access Journals (Sweden)

    Nanik Zubaidah

    2009-06-01

    Full Text Available Background: The aesthetic has an important role in social life, especially the anterior teeth. The aesthetic abnormality of anterior teeth i.e. discoloration, malpotition or the anterior teeth with crown damage for more than one third or all part of crown is lost due to caries or other causes, will influence its appearance especially during smile. Purpose: The aim of this case report, therefore, is to show how teeth with clinical crown lost or only the root left still can be treated by endorestoration treatment in order to reconstruct the shape and function of the teeth similar to the original ones. Case: Female 52 years old with the lost crown of anterior teeth. The patient did not want her teeth to be extracted. Case Management: The abnormality of these teeth are still able to be reconstructed by endorestoration i.e. endodontic treatment with post and core insertion in the root canal will increase its retention and recovery by the porcelain crown fused to metal to recover the original formation and aesthetic and thus has the normal refunction. The treatment, it improve the confidence of the patient, and also can function normally. The patient did not feel pain. Ronsenography showed the periapical lesion diminished, the neighbor gingival was going better in both function and color. Conclusion: Endorestoration treatment on the anterior teeth with lost crown could recover the normal function, dental aesthetic and self confidence.

  13. A semi-empirical model for predicting crown diameter of cedrela ...

    African Journals Online (AJOL)

    A semi-empirical model relating age and breast height has been developed to predict individual tree crown diameter for Cedrela odorata (L) plantation in the moist evergreen forest zones of Ghana. The model was based on field records of 269 trees, and could determine the crown cover dynamics, forecast time of canopy ...

  14. Incorporating crown dimensions into stem height and basal area for ...

    African Journals Online (AJOL)

    These increment models, with and without crown dimension were fitted to a modelling data set and the statistical significance of each of the crown dimensions was examined. All the models were then compared for predictive ability using an independent validation data set. The results obtained were similar for both the total ...

  15. URS Brava – a new oat cultivar with partial resistance to crown rust

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Federizzi

    2015-08-01

    Full Text Available The cultivar URS Brava, obtained from a simple cross between the line ‘UFRGS 995078-2’ and the cultivar ‘URS 21’, shows high grain yield and stability, high grain quality, desirable agronomical traits and partial resistance to crown rust, caused by the fungus Puccinia coronata f. sp. avenae.

  16. [Effects of repeated firing on microleakage of selective laser melting ceramic crowns].

    Science.gov (United States)

    Zhong, Qun; Peng, Yan; Wu, Xue-Ying; Weng, Jia-Wei

    2016-12-01

    To investigate the effects of repeated firing on microleakage of selective laser melting ceramic crowns. Fifty molars were randomly divided into 2 groups (25 teeth in each group). Teeth in group A received a chamfer finish line preparation, whereas teeth in group B received a shoulder finish line. After SLM metal crowns were fabricated, all the crowns received initial oxidation step, opaque firing, dentin firing and glaze firing, then crowns in each group were randomly divided into 5 sub-groups according to different time of clinical firings. Glass ionomer was applied for bonding. After 5000 thermocycles ranging from 5degrees centigrade to 55degrees centigrade, all the specimens was evaluated by dye penetration and then microleakage was examined under light microscopy. The data were analyzed with SPSS 20.0 software package. Microleakage between all specimens of group A were not statistically significant (P>0.05) whereas that of group B were statistically significant (P<0.05); After the fifth time of clinical firing, microleakage of specimens in group B(B5) were significantly higher than that of group A(A5). Repeated firings had no significant influence on marginal microleakage of SLM ceramic crowns whereas the crowns of chamfer finish lines result in better clinical performance after repeated firings.

  17. Simultaneously hermaphroditic shrimp use lipophilic cuticular hydrocarbons as contact sex pheromones.

    Science.gov (United States)

    Zhang, Dong; Terschak, John A; Harley, Maggy A; Lin, Junda; Hardege, Jörg D

    2011-04-20

    Successful mating is essentially a consequence of making the right choices at the correct time. Animals use specific strategies to gain information about a potential mate, which is then applied to decision-making processes. Amongst the many informative signals, odor cues such as sex pheromones play important ecological roles in coordinating mating behavior, enabling mate and kin recognition, qualifying mate choice, and preventing gene exchange among individuals from different populations and species. Despite overwhelming behavioral evidence, the chemical identity of most cues used in aquatic organisms remains unknown and their impact and omnipresence have not been fully recognized. In many crustaceans, including lobsters and shrimps, reproduction happens through a cascade of events ranging from initial attraction to formation of a mating pair eventually leading to mating. We examined the hypothesis that contact pheromones on the female body surface of the hermaphroditic shrimp Lysmata boggessi are of lipophilic nature, and resemble insect cuticular hydrocarbon contact cues. Via chemical analyses and behavioural assays, we show that newly molted euhermaphrodite-phase shrimp contain a bouquet of odor compounds. Of these, (Z)-9-octadecenamide is the key odor with hexadecanamide and methyl linoleate enhancing the bioactivity of the pheromone blend. Our results show that in aquatic systems lipophilic, cuticular hydrocarbon contact sex pheromones exist; this raises questions on how hydrocarbon contact signals evolved and how widespread these are in the marine environment.

  18. Simultaneously hermaphroditic shrimp use lipophilic cuticular hydrocarbons as contact sex pheromones.

    Directory of Open Access Journals (Sweden)

    Dong Zhang

    Full Text Available Successful mating is essentially a consequence of making the right choices at the correct time. Animals use specific strategies to gain information about a potential mate, which is then applied to decision-making processes. Amongst the many informative signals, odor cues such as sex pheromones play important ecological roles in coordinating mating behavior, enabling mate and kin recognition, qualifying mate choice, and preventing gene exchange among individuals from different populations and species. Despite overwhelming behavioral evidence, the chemical identity of most cues used in aquatic organisms remains unknown and their impact and omnipresence have not been fully recognized. In many crustaceans, including lobsters and shrimps, reproduction happens through a cascade of events ranging from initial attraction to formation of a mating pair eventually leading to mating. We examined the hypothesis that contact pheromones on the female body surface of the hermaphroditic shrimp Lysmata boggessi are of lipophilic nature, and resemble insect cuticular hydrocarbon contact cues. Via chemical analyses and behavioural assays, we show that newly molted euhermaphrodite-phase shrimp contain a bouquet of odor compounds. Of these, (Z-9-octadecenamide is the key odor with hexadecanamide and methyl linoleate enhancing the bioactivity of the pheromone blend. Our results show that in aquatic systems lipophilic, cuticular hydrocarbon contact sex pheromones exist; this raises questions on how hydrocarbon contact signals evolved and how widespread these are in the marine environment.

  19. Earth Pressure on Tunnel Crown

    DEFF Research Database (Denmark)

    Andersen, Lars

    Two different analyses have been carried out in order to find the vertical earth pressure, or overburden pressure, at the crown of a tunnel going through a dike. Firstly, a hand calculation is performed using a simple dispersion of the stresses over depth. Secondly, the finite‐element program...

  20. Wave Forces on Crown Walls

    DEFF Research Database (Denmark)

    Pedersen, Jan; Burcharth, H. F.

    1993-01-01

    This paper presents some of the results from a large parametric laboratory study including more than 200 long-duration model tests. The study addresses both the wave forces imposed on the breakwater crown wall as well as the performance of the structure in reducing the wave overtopping. The testing...

  1. [An in vitro study of the fracture strength of tooth preparations for Empress 2 veneers and crowns and mandibular incisors restored with Empress 2 veneers and crowns].

    Science.gov (United States)

    Wei, Xue; Li, Yan

    2009-12-01

    To compare the fracture resistance of mandibular incisors' preparations for veneers and crowns, mandibular incisors restored with Empress 2 veneers and crowns. 50 human mandibular incisors were randomly divided into five groups. Each group consisted of ten teeth and the treatment obtained as follows: A, tooth preparations for veneers; B, tooth preparations for crowns; C, teeth restored with veneers; D, teeth restored with crowns; E, untreated group. The teeth received standardized preparation and the restorations were manufactured with Empress 2 system and cemented with resin luting agent. The fracture resistances of teeth were measured by Instron universal testing machine and statistically analyzed with one-way ANOVA. The fracture resistances of A, B, C, D, E were (576.11 +/- 91.53), (204.13 +/- 85.88), (451.50 +/- 116.81), (386.16 +/- 117.75) and (566.05 +/- 121.37) N, respectively. The statistical analysis demonstrated significant differences between five groups. There were no significant differences between group A and E, group C and D. Tooth preparations for veneers did not significantly reduce the fracture resistance of mandibular incisor. The fracture resistance of teeth restored with Empress 2 veneers and crowns did not significantly differ from each other.

  2. A method for the preparation of lipophilic macrocyclic technetium-99m complexes

    International Nuclear Information System (INIS)

    Troutner, D.E.; Volkert, W.A.

    1991-01-01

    A procedure for the preparation of technetium complexes applicable as diagnostic radiopharmaceuticals is suggested and documented with 27 examples. Technetium-99m is reacted with a suitable complexant selected from the class of alkylenamine oximes containing 2 or 3 carbon atoms in the alkylene group. The lipophilic macrocyclic complexes possess an amine, amide, carboxy, carboxy ester, hydroxy or alkoxy group or a suitable electron acceptor group. (M.D.). 7 tabs

  3. Predictive performance of the human Cell Line Activation Test (h-CLAT) for lipophilic chemicals with high octanol-water partition coefficients.

    Science.gov (United States)

    Takenouchi, Osamu; Miyazawa, Masaaki; Saito, Kazutoshi; Ashikaga, Takao; Sakaguchi, Hitoshi

    2013-01-01

    To meet the urgent need for a reliable alternative test for predicting skin sensitizing potential of many chemicals, we have developed a cell-based in vitro test, human Cell Line Activation Test (h-CLAT). However, the predictive performance for lipophilic chemicals in the h-CLAT still remains relatively unknown. Moreover, it's suggested that low water solubility of chemicals might induce false negative outcomes. Thus, in this study, we tested relatively low water soluble 37 chemicals with log Kow values above and below 3.5 in the h-CLAT. The small-scale assessment resulted in nine false negative outcomes for chemicals with log Kow values greater than 3.5. We then created a dataset of 143 chemicals by combining the existing dataset of 106 chemicals and examined the predictive performance of the h-CLAT for chemicals with a log Kow of less than 3.5; a total of 112 chemicals from the 143 chemicals in the dataset. The sensitivity and overall accuracy for the 143 chemicals were 83% and 80%, respectively. In contrast, sensitivity and overall accuracy for the 112 chemicals with log Kow values below 3.5 improved to 94% and 88%, respectively. These data suggested that the h-CLAT could successfully detect sensitizers with log Kow values up to 3.5. When chemicals with log Kow values greater than 3.5 that were deemed positive by h-CLAT were included with the 112 chemicals, the sensitivity and accuracy in terms of the resulting applicable 128 chemicals out of the 143 chemicals became 95% and 88%, respectively. The use of log Kow values gave the h-CLAT a higher predictive performance. Our results demonstrated that the h-CLAT could predict sensitizing potential of various chemicals, which contain lipophilic chemicals using a large-scale chemical dataset.

  4. Survival Rates from Fracture of Endodontically Treated Premolars Restored with Full-coverage Crowns or Direct Resin Composite Restorations: A Retrospective Study.

    Science.gov (United States)

    Suksaphar, Warattama; Banomyong, Danuchit; Jirathanyanatt, Titalee; Ngoenwiwatkul, Yaowaluk

    2018-02-01

    The aim of the present study was to compare the survival rates against fracture of premolar endodontically treated teeth (ETT) restored with resin composite or crowns and to identify risk factors associated with the fracture. Data from dental records and radiographs of premolar ETT with postendodontic restorations (ie, resin composite or crowns) were collected between 2012 and 2016 and selected following selected inclusion and exclusion criteria. Tooth location, type of restoration, number of proximal contacts, and amount of tooth surface loss were recorded. The incidence and restorability of postendodontic fractures were identified. Survival rates against fracture of the 2 restoration types were calculated using Kaplan-Meier survival analysis. Any potential factors associated with fractures were identified using Cox proportional hazards models. The survival rate against fracture of ETT restored with crowns (95.1%) was higher than resin composite (77.0%). ETT restored with resin composite with 1 or 2 tooth surface losses and 2 proximal contacts had a high survival rate of 88.5% that was not significantly different from ETT with crowns. A higher incidence of restorability after fracture was observed in teeth restored with resin composite than crowns. The type of restoration and number of proximal contacts were identified as potential risk factors associated with fracture incidence. The survival rate against fracture of ETT restored with crowns was higher than resin composite. However, ETT with 1 or 2 tooth surface losses and 2 proximal contacts and restored with resin composite showed a high survival rate that was comparable with ETT restored with crowns. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  5. CROWN-LEVEL TREE SPECIES CLASSIFICATION USING INTEGRATED AIRBORNE HYPERSPECTRAL AND LIDAR REMOTE SENSING DATA

    Directory of Open Access Journals (Sweden)

    Z. Wang

    2018-05-01

    Full Text Available Mapping tree species is essential for sustainable planning as well as to improve our understanding of the role of different trees as different ecological service. However, crown-level tree species automatic classification is a challenging task due to the spectral similarity among diversified tree species, fine-scale spatial variation, shadow, and underlying objects within a crown. Advanced remote sensing data such as airborne Light Detection and Ranging (LiDAR and hyperspectral imagery offer a great potential opportunity to derive crown spectral, structure and canopy physiological information at the individual crown scale, which can be useful for mapping tree species. In this paper, an innovative approach was developed for tree species classification at the crown level. The method utilized LiDAR data for individual tree crown delineation and morphological structure extraction, and Compact Airborne Spectrographic Imager (CASI hyperspectral imagery for pure crown-scale spectral extraction. Specifically, four steps were include: 1 A weighted mean filtering method was developed to improve the accuracy of the smoothed Canopy Height Model (CHM derived from LiDAR data; 2 The marker-controlled watershed segmentation algorithm was, therefore, also employed to delineate the tree-level canopy from the CHM image in this study, and then individual tree height and tree crown were calculated according to the delineated crown; 3 Spectral features within 3 × 3 neighborhood regions centered on the treetops detected by the treetop detection algorithm were derived from the spectrally normalized CASI imagery; 4 The shape characteristics related to their crown diameters and heights were established, and different crown-level tree species were classified using the combination of spectral and shape characteristics. Analysis of results suggests that the developed classification strategy in this paper (OA = 85.12 %, Kc = 0.90 performed better than Li

  6. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study.

    Science.gov (United States)

    Arora, Sheen Juneja; Arora, Aman; Upadhyaya, Viram; Jain, Shilpi

    2016-01-01

    As, the longevity of provisional restorations is related to, a perfect adaptation and a strong, long-term union between restoration and teeth structures, therefore, evaluation of marginal leakage of provisional restorative materials luted with cements using the standardized procedures is essential. To compare the marginal leakage of the provisional crowns fabricated from Autopolymerizing acrylic resin crowns and bisphenol A-glycidyl dimethacrylate (BIS-GMA) resin crowns. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin crowns and BIS-GMA resin crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from autopolymerizing acrylic resin (SC-10) crowns cemented with different temporary luting cements. To compare the marginal leakage of the provisional crowns fabricated from BIS-GMA resin crowns (Protemp 4) cemented with different temporary luting cements. Freshly extracted 60 maxillary premolars of approximately similar dimensions were mounted in dental plaster. Tooth reduction with shoulder margin was planned to use a customized handpiece-holding jig. Provisional crowns were prepared using the wax pattern fabricated from computer aided designing/computer aided manufacturing milling machine following the tooth preparation. Sixty provisional crowns were made, thirty each of SC-10 and Protemp 4 and were then cemented with three different luting cements. Specimens were thermocycled, submerged in a 2% methylene blue solution, then sectioned and observed under a stereomicroscope for the evaluation of marginal microleakage. A five-level scale was used to score dye penetration in the tooth/cement interface and the results of this study was analyzed using the Chi-square test, Mann-Whitney U-test, Kruskal-Wallis H-test and the results were statistically significant P provisional crowns cemented with three different luting cements along the axial walls of

  7. Zirconia- versus metal-based, implant-supported abutments and crowns

    DEFF Research Database (Denmark)

    Hosseini, Mandana

    , the selection of restoration materials should be based on proper optical characteristics in addition to biocompatibility and sufficient strength of materials. Abutments and crowns based on zirconia are one of the most recent alternatives to metal abutments and metal-ceramic crowns. To date, only few comparative...... and to estimate long-term biomechanical results of zirconia-based versus metal-based restorations. The aim of study I was to analyse the mode of fracture and number of cyclic loadings until veneering fracture of zirconia-based all-ceramic restorations compared to metal-ceramic restorations. The aim of study II...... was to test the reliability and validity of six aesthetic parameters used at the Copenhagen Dental School to assess the aesthetic outcome of implant-supported restorations. The aims of study III and IV were to compare the influence of different abutment and crown materials on biological, biomechanical...

  8. Environmental and biological cues for spawning in the crown-of-thorns starfish.

    Directory of Open Access Journals (Sweden)

    Ciemon Frank Caballes

    Full Text Available Sporadic outbreaks of the coral-eating crown-of-thorns starfish are likely to be due, at least in part, to spatial and temporal variation in reproductive and settlement success. For gonochoric and broadcast spawning species such as crown-of-thorns starfish, spawning synchrony is fundamental for achieving high rates of fertilization. Highly synchronized gamete release within and among distinct populations is typically the result of the entrainment of neurohormonal endogenous rhythms by cues from the environment. In this study, we conducted multiple spawning assays to test the effects of temperature change, reduced salinity and nutrient enrichment of seawater, phytoplankton, gametes (sperm and eggs, and the combined effect of sperm and phytoplankton on the likelihood of spawning in male and female crown-of-thorns starfish. We also investigated sex-specific responses to each of these potential spawning cues. We found that (1 abrupt temperature change (an increase of 4°C induced spawning in males, but less so in females; (2 males often spawned in response to the presence of phytoplankton, but none of the females spawned in response to these cues; (3 the presence of sperm in the water column induced males and females to spawn, although additive and synergistic effects of sperm and phytoplankton were not significant; and (4 males are more sensitive to the spawning cues tested and most likely spawn prior to females. We propose that environmental cues act as spawning 'inducers' by causing the release of hormones (gonad stimulating substance in sensitive males, while biological cues (pheromones from released sperm, in turn, act as spawning 'synchronizers' by triggering a hormonal cascade resulting in gamete shedding by conspecifics. Given the immediate temporal linkage between the timing of spawning and fertilization events, variability in the extent and synchronicity of gamete release will significantly influence reproductive success and may account

  9. Influence of structure of crown ethers on their radiation stability

    International Nuclear Information System (INIS)

    Grigor'ev, E.I.; Myasoedova, T.G.; Nesterov, S.V.; Trakhtenberg, L.I.

    1988-01-01

    Primary products of γ-radiolysis of crown ethers with the same size of the macrocyclic ring and different substituents were studied by EPR and mass spectrometry. It was shown that introduction of substituents into the polyether ring increases the radiation stability of crown ethers due to intramolecular transfer of energy from the polyether ring to a substituent

  10. Increasing the thermopower of crown-ether-bridged anthraquinones

    Science.gov (United States)

    Ismael, Ali K.; Grace, Iain; Lambert, Colin J.

    2015-10-01

    We investigate strategies for increasing the thermopower of crown-ether-bridged anthraquinones. The novel design feature of these molecules is the presence of either (1) crown-ether or (2) diaza-crown-ether bridges attached to the side of the current-carrying anthraquinone wire. The crown-ether side groups selectively bind alkali-metal cations and when combined with TCNE or TTF dopants, provide a large phase-space for optimising thermoelectric properties. We find that the optimum combination of cations and dopants depends on the temperature range of interest. The thermopowers of both 1 and 2 are negative and at room temperature are optimised by binding with TTF alone, achieving thermpowers of -600 μV K-1 and -285 μV K-1 respectively. At much lower temperatures, which are relevant to cascade coolers, we find that for 1, a combination of TTF and Na+ yields a maximum thermopower of -710 μV K-1 at 70 K, whereas a combination of TTF and Li+ yields a maximum thermopower of -600 μV K-1 at 90 K. For 2, we find that TTF doping yields a maximum thermopower of -800 μV K-1 at 90 K, whereas at 50 K, the largest thermopower (of -600 μV K-1) is obtain by a combination TTF and K+ doping. At room temperature, we obtain power factors of 73 μW m-1 K-2 for 1 (in combination with TTF and Na+) and 90 μW m-1 K-2 for 2 (with TTF). These are higher or comparable with reported power factors of other organic materials.We investigate strategies for increasing the thermopower of crown-ether-bridged anthraquinones. The novel design feature of these molecules is the presence of either (1) crown-ether or (2) diaza-crown-ether bridges attached to the side of the current-carrying anthraquinone wire. The crown-ether side groups selectively bind alkali-metal cations and when combined with TCNE or TTF dopants, provide a large phase-space for optimising thermoelectric properties. We find that the optimum combination of cations and dopants depends on the temperature range of interest. The

  11. Direct composite restoration of permanent anterior teeth uncomplicated crown fractures

    Directory of Open Access Journals (Sweden)

    Ashley Evans Nicholas

    2018-01-01

    Full Text Available An uncomplicated crown fracture is a fracture that involves only the tooth enamel or the dentin and tooth enamel without any damage or exposure to the pulp. Crown fracture of the anterior teeth usually caused by traumatic forces such as falls, accidents, violence, or sports activities. Traumatic injuries of the oral region frequently involve the anterior teeth, especially maxillary incisors due to the anatomic factors which may affect the functional and aesthetical values of the teeth. The objective of this literature study was to know more about uncomplicated crown fracture of the anterior teeth and its restoration. This research was a literature study performed by researching, highlighting various interesting facts and compiling the relevant published journals. The most common and ideal direct restoration of the anterior teeth was the composite resin restoration. The anterior teeth restoration was considered to be a complex and challenging case to solves due to the fact that besides reconstructing the tooth and regaining the function, the aesthetical aspect was also becoming the main objectives. The permanent anterior teeth uncomplicated crown fracture was the most common case of tooth fractures which was mainly caused by traumatic injuries such as falls, accidents, excessive forces, violence, and also sports activities. Dental injuries of the anterior teeth also affected the aesthetical properties and the function of the tooth. Composite resin restoration was able to performed directly on the permanent anterior teeth uncomplicated crown fracture.

  12. Lipophilic extractives from several nonwoody lignocellulosic crops (flax, hemp, sisal, abaca) and their fate during alkaline pulping and TCF/ECF bleaching.

    Science.gov (United States)

    Marques, Gisela; del Río, José C; Gutiérrez, Ana

    2010-01-01

    The fate of lipophilic extractives from several nonwoody species (flax, hemp, sisal and abaca) used for the manufacturing of cellulose pulps, was studied during soda/anthraquinone (AQ) pulping and totally chorine free (TCF) and elemental chlorine free (ECF) bleaching. With this purpose, the lipophilic extracts from the raw materials and their unbleached and bleached industrial pulps, were analyzed by gas chromatography-mass spectrometry. Aldehydes, hydroxyfatty acids and esterified compounds such as ester waxes, sterol esters and alkylferulates strongly decreased after soda/AQ pulping while alkanes, alcohols, free sterols and sterol glycosides survived the cooking process. Among the lipophilic extractives that remained in the unbleached pulps, some amounts of free sterols were still present in the TCF pulps whereas they were practically absent in the ECF pulps. Sterol glycosides were also removed after both TCF and ECF bleaching. By contrast, saturated fatty acids, fatty alcohols and alkanes were still present in both bleached pulps.

  13. Influence of Abutment Design on Stiffness, Strength, and Failure of Implant-Supported Monolithic Resin Nano Ceramic (RNC) Crowns.

    Science.gov (United States)

    Joda, Tim; Huber, Samuel; Bürki, Alexander; Zysset, Philippe; Brägger, Urs

    2015-12-01

    Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation. © 2014 Wiley Periodicals, Inc.

  14. Enhanced delivery of ketobemidone through porcine buccal mucosa in vitro via more lipophilic ester prodrugs

    DEFF Research Database (Denmark)

    Hansen, L.B.; Christrup, Lona Louring; Bundgaard, H.

    1992-01-01

    of permeation relative to ketobemidone, the permeability coefficients being 3-30-times higher than that of ketobemidone. The permeability coefficients increased with increasing lipophilicity, expressed in terms of octanol-buffer (pH 7.4) partition coefficients (P), up to log P values of about 1.5 whereupon...

  15. Co-delivery of antigen and a lipophilic anti-inflammatory drug to cells via a tailorable nanocarrier emulsion.

    Science.gov (United States)

    Chuan, Yap Pang; Zeng, Bi Yun; O'Sullivan, Brendan; Thomas, Ranjeny; Middelberg, Anton P J

    2012-02-15

    Nanotechnology promises new drug carriers that can be tailored to specific applications. Here we report a new approach to drug delivery based on tailorable nanocarrier emulsions (TNEs), motivated by a need to co-deliver a protein antigen and a lipophilic drug for specific inhibition of nuclear factor kappa B (NF-κB) in antigen presenting cells (APCs). Co-delivery for NF-κB inhibition holds promise as a strategy for the treatment of rheumatoid arthritis. We used a highly surface-active peptide (SAP) to prepare a nanosized emulsion having defined surface properties predictable from the SAP sequence. Incorporating the lipophilic drug into the oil phase at the time of emulsion formation enabled its facile packaging. The SAP is depleted from bulk during emulsification, allowing simple subsequent addition of the drug-loaded oil-in-water emulsion to a solution of protein antigen. Decoration of emulsion surface with antigen was achieved via electrostatic deposition. In vitro data showed that the TNE prepared this way was internalized and well-tolerated by model APCs, and that good suppression of NF-κB expression was achieved. This work reports a new type of nanotechnology-based carrier, a TNE, which can potentially be tailored for co-delivery of multiple therapeutic components, and can be made using simple methods using only biocompatible materials. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. A 20-Year Overview of Quercus robur L. Mortality and Crown Conditions in Slovenia

    Directory of Open Access Journals (Sweden)

    Matjaž Čater

    2015-02-01

    Full Text Available Pedunculate oak (Quercus robur L. forests in Slovenia are experiencing widespread mortality. Changes in lowlands are reflected in decline of complete forest complexes, high mortality, uneven stand structure and associated forest regeneration problems. Prediction of the present-tree response in disturbed forest ecosystems may significantly contribute to better guideline policies for the silvicultural and forest management practice in the changing environment in both stressed and stabile forest ecosystems. Data from annual crown condition surveys for the 1995–2014 period from four permanent plots have been compared with parameters from hemispherical photo analysis and hydrometeorological data. Good agreement has been confirmed between crown defoliation and total openness; all parameters from the hemispherical photo analysis, which were corrected for winter period values, also indicated a better agreement. Mortality rate and crown defoliation correlated well with extreme drought events in 2003 and 2013. Pattern of agreement among compared parameters was different for the plots Krakovski gozd, Dobrava and some other plots. Mortality is influenced by the average air temperatures much more than by precipitation and groundwater table oscillations.

  17. Kinetically inert lanthanide complexes as reporter groups for binding of potassium by 18-crown-6

    DEFF Research Database (Denmark)

    Junker, Anne Kathrine Ravnsborg; Tropiano, Manuel; Faulkner, Stephen

    2016-01-01

    in a copper(I)-catalyzed alkyne-azide cycloaddition (CuAAC) “click” reaction with azide-functionalized crown ethers. The resulting complexes were investigated using NMR and optical methods. Titrations with potassium chloride in methanol observing the sensititzed europium- and terbium-centered emissions were......-centered emission to report on the binding of potassium in an 18-crown-6 binding pocket. The responsive systems were made by linking a crown ether to a kinetically inert lanthanide binding pocket using a molecular building block approach. Specifically, an alkyne-appended Ln.DO3A was used as a building block...... used to investigate the response of the systems. The molecular reporters based on aliphatic crown ethers were found to have strongly inhibited binding of potassium, while the benzo-18-crown-6 derived systems had essentially the same association constants as the native crown ethers. The shape...

  18. Effect of Crystallization Firing on Marginal Gap of CAD/CAM Fabricated Lithium Disilicate Crowns.

    Science.gov (United States)

    Gold, Steven A; Ferracane, Jack L; da Costa, Juliana

    2018-01-01

    To evaluate the marginal gaps of CAD/CAM (CEREC 3) produced crowns made from leucite-reinforced glass-ceramic (IPS Empress CAD) blocks (LG), and lithium-disilicate (IPS e.max CAD) blocks before (LD-B), and after (LD-A) crystallization firing. A human molar tooth (#19) was mounted with adjacent teeth on a typodont and prepared for a full-coverage ceramic crown. The typodont was assembled in the mannequin head to simulate clinical conditions. After tooth preparation 15 individual optical impressions were taken by the same operator using titanium dioxide powder and a CEREC 3 camera per manufacturer's instructions. One operator designed and machined the crowns in leucite-reinforced glass-ceramic blocks (n = 5) and lithium-disilicate blocks (n = 10) using the CEREC 3 system. The crowns were rigidly seated on the prepared tooth, and marginal gaps (μm) were measured with an optical microscope (500×) at 12 points, 3 on each of the M, B, D, and L surfaces of the leucite-reinforced glass-ceramic crowns and the lithium-disilicate crowns before and after crystallization firing. Results were analyzed by two-way ANOVA followed by a Tukey's post hoc multiple comparison test (α = 0.05). The overall mean marginal gaps (μm) for the crowns evaluated were: LG = 49.2 ± 5.5, LD-B = 42.9 ± 12.2, and LD-A = 57.2 ± 16.0. The marginal gaps for LG and LD-B were not significantly different, but both were significantly less than for LD-A. The type of ceramic material did not affect the marginal gap of CAD/CAM crowns. The crystallization firing process required for lithium-disilicate crowns resulted in a significant increase in marginal gap size, likely due to shrinkage of the ceramic during the crystallization process. The marginal gap of CAD/CAM-fabricated lithium disilicate crowns increases following crystallization firing. The marginal gap still remains within clinically acceptable parameters. © 2017 by the American College of Prosthodontists.

  19. Evaluation of the Effect of Surgical Crown Lengthening on Periodontal Parameters

    Directory of Open Access Journals (Sweden)

    Farzane Vaziri

    2015-09-01

    Full Text Available Background: Surgical crown lengthening is needed for teeth with subgingival caries, fractured teeth, insufficient crown length, and deep subgingival margin of failed restorations. Since there is no agreement on the effects of crown lengthening surgery on gingival parameters, the purpose of this study was to evaluate periodontal parameters in patients who needed crown lengthening surgery. Methods: Twenty patients who had healthy periodontium and needed surgical crown lengthening were included in this study. After professional dental cleaning, gingival parameters including gingival index (GI, probing depth (PD, bone level (BL, and transsulcular probing (TSP were recorded in interproximal and keratinized gingiva (KG in mid buccal portion. The patients were evaluated one and three months after the surgery. Results: After one and three months of the surgery, the amount of PD reduced from 2.32 mm to 1.25 mm and 1.17 mm, respectively (P=0.001. The mean of BL reduction was 0.88 mm after one month (P=0.001, but there was no reduction between 1 month and 3 months. Amounts of KG at baseline andone month later were 4.2 mm and 2.9 mm, respectively (P=0.001, and remained at the same level up to three months. TSP significantly reduced (from 3.67 mm at baseline to 2.62 mm after 1 month, and to 2.27 mm after 3 months (P=0.001, P=0.005. Conclusion: The present  study suggests that in the presence of good oral hygiene, except BW (biological width, other parameters including PD, BL, KG, and TSP had significant changes after crown lengthening surgery in the period of 1 month and 3 months (P

  20. Lipophilic extractives and the loss of solid material in mechanical pulp washing; Rasvaliukoiset uuteaineet ja kiintoainetappiot mekaanisen massan katkaisupesussa - EKT 02

    Energy Technology Data Exchange (ETDEWEB)

    Manner, H.; Kaeyhkoe, J.; Keskinen, K. [Lappeenranta Univ. of Technology (Finland). Lab. of Paper Technology

    1998-12-31

    In this project the aim is to produce basic information for the optimization of mechanical pulp washing. In the first stage, the main emphasis is put on the behavior of lipophilic extractives and on the solid material which is lost during washing. The first task was to make the simulation of mill scale washing processes on a laboratory scale possible. This has been achieved by building two laboratory scale presses and comparing them to mill scale presses. The experimental information obtained there from verified that similar conditions could be obtained on a laboratory scale as from mill scale presses. The main research areas and results obtained in this project are: Washing studies: A considerable deresination efficiency can be obtained in a single washing stage with reasonable water usage. Dissolution and dispersion of wood components in the mixing: Temperature, time and power in the mixing of mechanical pulp has a significant effect on the dispersion of the lipophilic extractives. Also, the dissolution and dispersion of wood components in the mixing may form quite a complex issue to study. Form of the lipophilic extractives in the filtrates: The amount of lipophilic extractives in the solid phase of the filtrates obtained from the presses was so low that it had no effect on the deresination efficiency. The effect of the dispersing agents on the deresination efficiency: The deresination efficiency can be significantly improved by the optimum usage of dispersing agents. Research work in these areas will be continued. (orig.)

  1. Lipophilic extractives and the loss of solid material in mechanical pulp washing; Rasvaliukoiset uuteaineet ja kiintoainetappiot mekaanisen massan katkaisupesussa - EKT 02

    Energy Technology Data Exchange (ETDEWEB)

    Manner, H; Kaeyhkoe, J; Keskinen, K [Lappeenranta Univ. of Technology (Finland). Lab. of Paper Technology

    1999-12-31

    In this project the aim is to produce basic information for the optimization of mechanical pulp washing. In the first stage, the main emphasis is put on the behavior of lipophilic extractives and on the solid material which is lost during washing. The first task was to make the simulation of mill scale washing processes on a laboratory scale possible. This has been achieved by building two laboratory scale presses and comparing them to mill scale presses. The experimental information obtained there from verified that similar conditions could be obtained on a laboratory scale as from mill scale presses. The main research areas and results obtained in this project are: Washing studies: A considerable deresination efficiency can be obtained in a single washing stage with reasonable water usage. Dissolution and dispersion of wood components in the mixing: Temperature, time and power in the mixing of mechanical pulp has a significant effect on the dispersion of the lipophilic extractives. Also, the dissolution and dispersion of wood components in the mixing may form quite a complex issue to study. Form of the lipophilic extractives in the filtrates: The amount of lipophilic extractives in the solid phase of the filtrates obtained from the presses was so low that it had no effect on the deresination efficiency. The effect of the dispersing agents on the deresination efficiency: The deresination efficiency can be significantly improved by the optimum usage of dispersing agents. Research work in these areas will be continued. (orig.)

  2. Distribution and prevalence of crown rot pathogens affecting wheat crops in southern Chile

    Directory of Open Access Journals (Sweden)

    Ernesto Moya-Elizondo

    2015-03-01

    Full Text Available Crown rot pathogens are associated with higher losses for wheat crop farmers, but information about the distribution and prevalence of these pathogens in Chile is inadequate. Distribution and prevalence of wheat (Triticum aestivum L. crown rot pathogens were examined in a survey of 48 commercial fields from December 2011 to February 2012 in southern Chile. These fields were located between Collipulli (37°56'00" S; 72°26'39" W and Purranque (40°50'30" S; 73°22'03" W. Severity of crown rot disease was determined through visual assessment of the first internode of 20 tillers obtained from each field. Incidence of crown rot pathogens per field was determined by plating the 20 tillers on Petri plates with 20% potato dextrose agar amended with lactic acid (aPDA medium. Resulting fungal colonies from monoxenic culture were identified by morphological or molecular-assisted identification. Severity of crown rot varied between 11.3% and 80% for individual fields. Culture plate analysis showed 72.2% of stems were infected with some fungus. Fusarium avenaceum, F. graminearum, and F. culmorum, pathogens associated with Fusarium crown rot disease were isolated from 13.5% of tillers. Gaeumannomyces graminis, causal agent of take-all disease in cereals, was isolated from 11.1% of culms. Phaeosphaeria sp., an endophyte and possibly a non-pathogenic fungus, was isolated from 13.9% of tillers. Pathogenic fungi such as Rhizoctonia spp. and Microdochium nivale, other saprophyte, and several unidentified non-sporulating fungi were isolated at frequencies lower than 3% of the total. Fusarium crown rot and take-all were the most prevalent and distributed crown rot diseases present in wheat crops in southern Chile.

  3. Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

    Science.gov (United States)

    Kim, Tae-Gyung; Kim, Sungtae; Lee, Jae-Hoon

    2016-01-01

    The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n = 40). For ICC (Intraoral, CAD/CAM) group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver) machinable alloy were generated. For IC (Intraoral, Cast) group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM) group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast) group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α = 0.05). The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P 0.05). Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions. PMID:28018914

  4. Clinical Acceptability of the Internal Gap of CAD/CAM PD-AG Crowns Using Intraoral Digital Impressions

    Directory of Open Access Journals (Sweden)

    Tae-Gyung Kim

    2016-01-01

    Full Text Available The purpose of this study was to compare the internal gap between CAD/CAM palladium-silver crowns and cast gold crowns generated from intraoral digital versus conventional impressions and to determine the clinical acceptability. Nickel-chrome master dies were made from the prepared resin tooth with the conventional impression method (n=40. For ICC (Intraoral, CAD/CAM group, 10 intraoral digital impressions were made, and 10 CAD/CAM crowns of a PD-AG (palladium-silver machinable alloy were generated. For IC (Intraoral, Cast group, 10 gold crowns were cast from ten intraoral digital impressions. For CCC (Conventional, CAD/CAM group, 10 CAD/CAM PD-AG crowns were made using the conventional impression method. For CC (Conventional, Cast group, 10 gold crowns were fabricated from 10 conventional impressions. One hundred magnifications of the internal gaps of each crown were measured at 50 points with an optical microscope and these values were statistically analyzed using a two-way analysis of variance (α=0.05. The internal gap of the intraoral digital impression group was significantly larger than in the conventional impression group (P0.05. Within the limitations of this in vitro study, crowns from intraoral digital impressions showed larger internal gap values than crowns from conventional impressions.

  5. Antiproliferative Effects of Cynara cardunculus L. var. altilis (DC Lipophilic Extracts

    Directory of Open Access Journals (Sweden)

    Patrícia A. B. Ramos

    2016-12-01

    Full Text Available Besides being traditionally used to relieve hepatobiliary disorders, Cynara cardunculus L. has evidenced anticancer potential on triple-negative breast cancer (TNBC. This study highlights the antiproliferative effects of lipophilic extracts from C. cardunculus L. var. altilis (DC leaves and florets, and of their major compounds, namely cynaropicrin and taraxasteryl acetate, against MDA-MB-231 cells. Our results demonstrated that MDA-MB-231 cells were much less resistant to leaves extract (IC50 10.39 µg/mL than to florets extract (IC50 315.22 µg/mL, during 48 h. Moreover, leaves extract and cynaropicrin (IC50 6.19 µg/mL suppressed MDA-MB-231 cells colonies formation, via an anchorage-independent growth assay. Leaves extract and cynaropicrin were also assessed regarding their regulation on caspase-3 activity, by using a spectrophotometric assay, and expression levels of G2/mitosis checkpoint and Akt signaling pathway proteins, by Western blotting. Leaves extract increased caspase-3 activity, while cynaropicrin did not affect it. Additionally, they caused p21Waf1/Cip1 upregulation, as well as cyclin B1 and phospho(Tyr15-CDK1 accumulation, which may be related to G2 cell cycle arrest. They also downregulated phospho(Ser473-Akt, without changing total Akt1 level. Cynaropicrin probably contributed to leaves extract antiproliferative action. These promising insights suggest that cultivated cardoon leaves lipophilic extract and cynaropicrin may be considered toward a natural-based therapeutic approach on TNBC.

  6. Digital evaluation of the fit of zirconia-reinforced lithium silicate crowns with a new three-dimensional approach.

    Science.gov (United States)

    Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis

    2017-11-30

    -AX. The largest internal adaptation of the crowns was measured for the occlusal surface with 258.9 ± 39.2 µm for group MI-OC and 260.6 ± 55.0 µm for group FG-OC. No statistically significant differences were found for the post-milling protocols (P > .05). The 3D difference pattern was visually analyzed for each area with a color-coded scheme. Post-milling processing did not affect the internal adaptation of zirconia-reinforced lithium silicate crowns fabricated with a chairside CAD/CAM technique. The new 3D computer technique for the evaluation of fit of restorations may be highly promising and has the opportunity to be applied to clinical studies.

  7. Crystal structure of cis-anti-cis-dicyclohexane-18-crown-6 acetonitrile disolvate

    Directory of Open Access Journals (Sweden)

    Alexander Nazarenko

    2015-07-01

    Full Text Available The title compound (systematic name: cis-anti-cis-2,5,8,15,18,21-hexaoxatricyclo[20.4.0.09,14]hexacosane acetonitrile disolvate, C20H36O6·2CH3CN, crystallizes from an acetonitrile solution of dicyclohexane-18-crown-6 on evaporation. The molecule is arranged around a center of symmetry with half the crown ether molecule and one molecule of acetonitrile symmetry independent. All O—C—C—O torsion angles are gauche while all C—O—C—C angles are trans. The sequence of torsion angles is [(tg+t(tg−t]3; the geometry of oxygen atoms is close to pseudo-D3d with three atoms below and three atoms above the mean plane, with an average deviation of ±0.16 (1 Å from the mean plane. This geometry is identical to that observed in metal ion complexes of dicyclohexane-18-crown-6 but differs significantly from the conformation of a free unsolvated molecule. Each acetonitrile molecule connects to a crown ether molecule via two of its methyl group H atoms (C—H...O. Weaker interactions exist between the third H atom of the acetonitrile methyl group and an O atom of a neighbouring crown ether molecule (C—H...O; and between the N atom of the acetonitrile molecule and a H atom of another neighbouring crown ether molecule. All these intermolecular interactions create a three-dimensional network stabilizing the disolvate.

  8. [Effects of habitat fragmentation on nesting site selection of red-crowned crane].

    Science.gov (United States)

    Wan, Dongmei; Gao, Wei; Wang, Qiuyu; Wang, Haitao; Liu, Mingyu

    2002-05-01

    During April and May of 1985, 1995 and 1998, red-crowned crane's nesting and variation of breeding population quantities in Shuangtaihekou National Natural Reserve in Liaoning, and also the habitat fragmentation there were investigated. Associated with previous data of the reserve, red-crowned crane's nesting habitat had been seriously fragmentated into 91 patches from one integrated reed wetland. The area of the smallest patch was 0.37 km2, and the minimum distance of two nests was 304 m. Compared with records of previous data, the minimum area of nesting habitat reduced by 0.72 km2. However, the breeding population quantities of red-crowned crane had maintained at about 30 pairs for a long period. The red-crowned crane adapted to the changed environment by the ecological adaptation strategy of reducing area of nesting habitat.

  9. Influence of different post core materials on the color of Empress 2 full ceramic crowns.

    Science.gov (United States)

    Ge, Jing; Wang, Xin-zhi; Feng, Hai-lan

    2006-10-20

    For esthetic consideration, dentin color post core materials were normally used for all-ceramic crown restorations. However, in some cases, clinicians have to consider combining a full ceramic crown with a metal post core. Therefore, this experiment was conducted to test the esthetical possibility of applying cast metal post core in a full ceramic crown restoration. The color of full ceramic crowns on gold and Nickel-Chrome post cores was compared with the color of the same crowns on tooth colored post cores. Different try-in pastes were used to imitate the influence of a composite cementation on the color of different restorative combinations. The majority of patients could not detect any color difference less than DeltaE 1.8 between the two ceramic samples. So, DeltaE 1.8 was taken as the objective evaluative criterion for the evaluation of color matching and patients' satisfaction. When the Empress 2 crown was combined with the gold alloy post core, the color of the resulting material was similar to that of a glass fiber reinforced resin post core (DeltaE = 0.3). The gold alloy post core and the try-in paste did not show a perceptible color change in the full ceramic crowns, which indicated that the color of the crowns might not be susceptible to change between lab and clinic as well as during the process of composite cementation. Without an opaque covering the Ni-Cr post core would cause an unacceptable color effect on the crown (DeltaE = 2.0), but with opaque covering, the color effect became more clinically satisfactory (DeltaE = 1.8). It may be possible to apply a gold alloy post core in the Empress 2 full ceramic crown restoration when necessary. If a non-extractible Ni-Cr post core exists in the root canal, it might be possible to restore the tooth with an Empress 2 crown after covering the labial surface of the core with one layer of opaque resin cement.

  10. Comparative evaluation of marginal leakage of provisional crowns cemented with different temporary luting cements: In vitro study

    Directory of Open Access Journals (Sweden)

    Sheen Juneja Arora

    2016-01-01

    Conclusion: The temporary cements with eugenol showed more microleakage than those without eugenol. SC-10 crowns showed more microleakage compared to Protemp 4 crowns. SC-10 crowns cemented with Kalzinol showed maximum microleakage and Protemp 4 crowns cemented with HY bond showed least microleakage.

  11. Crown-Stump Diameter Model for Parkia biglobosa Benth. Species in Makurdi, Benue State, Nigeria

    Directory of Open Access Journals (Sweden)

    O. Chukwu

    2017-07-01

    Full Text Available The crown of tree is the centre of physiological activity which gives an indication of the potential photosynthetic capacity on a tree. Though, its measurement remains a challenge in forest inventory task. The ability to predict crown diameter from stump diameter provides an effective technique of obtaining its estimate. This helps in detecting the excessive tree felling than actual requirements and wildlife suitability.The main objective of this study was to develop and test crown diameter prediction models for silvicultural management of naturally grown Parkia biglobosa within the University of Agriculture, Makurdi. Nine 100 m x 100 m temporary sample plots were established using simple random sampling method. Crown diameter and stump diameter were measured in all living P. biglobosa trees with stump diameter ≥10.0 cm. Least square method was used to convert the counted stumps into harvested crown dimension. Three linear and three non-linear models using stump diameter as the exploratory variable were developed and evaluated using the adjusted coefficient of determination (Adj.R2, standard error of estimate (SEE, prediction error sum of squares (PRESS and Akaike information criterion (AIC. The crown-stump diameter relationship was best described by the double logarithmic function with .The result showed that Crown diameter estimation was feasible even when the only information available is stump diameter.The resulting equation was tested for validation with independent data obtained from additional plots and was found to be desirable for estimating the crown diameter for Parkia biglobosa in Makurdi, Benue State, Nigeria.

  12. Crown ether complexes of lanthanoid and actinoid elements. Crystal and molecular structure of Nd(NO/sub 3/)/sub 3/(18-crown-6)

    Energy Technology Data Exchange (ETDEWEB)

    Bombieri, G; De Paoli, G; Benetollo, F [Consiglio Nazionale delle Ricerche, Padua (Italy). Lab. di Chimica e Tecnologia dei Radioelementi; Cassol, A [Padua Univ. (Italy)

    1980-01-01

    Nd(NO/sub 3/)/sub 3/.18-Crown-6 crystallizes in the orthorhombic system, space group Pbca with eight molecules in a cell of dimensions a = 15.512(9), b = 21.662(1), c = 12.141(6) A. The structure has been determined by Patterson heavy-atom methods and refined by full-matrix least squares to R = 0.038. The neodymium atom is coordinated by 6 oxygen atoms of the 18-crown-6 unit and by three bidentate nitrate groups; one on the more hindered side of the ring and two on the opposite side.

  13. Accuracy of LiDAR-based tree height estimation and crown recognition in a subtropical evergreen broad-leaved forest in Okinawa, Japan

    Directory of Open Access Journals (Sweden)

    Azita Ahmad Zawawi

    2015-04-01

    Full Text Available Aim of study: To present an approach for estimating tree heights, stand density and crown patches using LiDAR data in a subtropical broad-leaved forest. Area of study: The study was conducted within the Yambaru subtropical evergreen broad-leaved forest, Okinawa main island, Japan. Materials and methods: A digital canopy height model (CHM was extracted from the LiDAR data for tree height estimation and a watershed segmentation method was applied for the individual crown delineation. Dominant tree canopy layers were estimated using multi-scale filtering and local maxima detection. The LiDAR estimation results were then compared to the ground inventory data and a high resolution orthophoto image for accuracy assessment. Main results: A Wilcoxon matched pair test suggests that LiDAR data is highly capable of estimating tree height in a subtropical forest (z = 4.0, p = 0.345, but has limitation to detect small understory trees and a single tree delineation. The results show that there is a statistically significant different type of crown detection from LiDAR data over forest inventory (z = 0, p = 0.043. We also found that LiDAR computation results underestimated the stand density and overestimated the crown size. Research highlights: Most studies involving crown detection and tree height estimation have focused on the analysis of plantations, boreal forests and temperate forests, and less was conducted on tropical and/or subtropical forests. Our study tested the capability of LiDAR as an effective application for analyzing a highly dense forest

  14. Conductometric study of reaction kinetics between potassium superoxide and 18-crown-6 in dimethylsulfoxide

    International Nuclear Information System (INIS)

    Efimova, I.V.; Opejda, I.A.

    2000-01-01

    Complexing within KO 2 -18-crown-6-solvent, KOH-18-crown-6-solvent and KI-KO 2 -18-crown-6-solvent systems in dimethylsulfoxide was studied by measurement of electrical conductivity. It was shown that time variation of electrical conductivity under the given conditions was described by the Erofeev-Auramy equation, the coefficients of that equation for various systems were determined, time to reach equilibrium state was estimated. Linear dependences of electrical conductivity of KI-KO 2 salt solutions at presence of 18-crown-6 at the state of equilibrium in contrast to the component concentrations were determined [ru

  15. Preformation in vegetative buds of pistachio (Pistacia vera): relationship to shoot morphology, crown structure and rootstock vigor.

    Science.gov (United States)

    Spann, Timothy M; Beede, Robert H; Dejong, Theodore M

    2007-08-01

    Effects of rootstock, shoot carbohydrate status, crop load and crown position on the number of preformed leaf primordia in the dormant terminal and lateral buds of mature and immature 'Kerman' pistachio (Pistacia vera L.) trees were investigated to determine if rootstock vigor is associated with greater shoot preformation. There was no significant variation in preformation related to the factors studied, suggesting strong genetic control of preformation in 'Kerman' pistachio. The growth differences observed among trees on different rootstocks were associated with greater stimulation of neoformed growth in trees on the more vigorous rootstocks. However, most annual extension growth in mature tree crowns was preformed, contrasting with the relatively high rate of neoformation found in young tree crowns. Large amounts of neoformed growth in young trees may allow the trees to become established quickly and secure resources, whereas predominantly preformed growth in mature trees may allow for continued crown expansion without outgrowing available resources. We hypothesized that the stimulation of neoformed growth by the more vigorous rootstocks is associated with greater resource uptake or transport, or both. Understanding the source of variation in shoot extension growth on different rootstocks has important implications for orchard management practices.

  16. Mandibular molar crown-topography, a biological predisposing ...

    African Journals Online (AJOL)

    Mandibular molar crown-topography, a biological predisposing factor to development of caries – a post-mortem analysis of 2500 extracted lower permanent molars at the dental centre, University of Benin teaching hospital.

  17. The expression of light-related leaf functional traits depends on the location of individual leaves within the crown of isolated Olea europaea trees.

    Science.gov (United States)

    Escribano-Rocafort, Adrián G; Ventre-Lespiaucq, Agustina B; Granado-Yela, Carlos; Rubio de Casas, Rafael; Delgado, Juan A; Balaguer, Luis

    2016-04-01

    The spatial arrangement and expression of foliar syndromes within tree crowns can reflect the coupling between crown form and function in a given environment. Isolated trees subjected to high irradiance and concomitant stress may adjust leaf phenotypes to cope with environmental gradients that are heterogeneous in space and time within the tree crown. The distinct expression of leaf phenotypes among crown positions could lead to complementary patterns in light interception at the crown scale. We quantified eight light-related leaf traits across 12 crown positions of ten isolated Olea europaea trees in the field. Specifically, we investigated whether the phenotypic expression of foliar traits differed among crown sectors and layers and five periods of the day from sunrise to sunset. We investigated the consequences in terms of the exposed area of the leaves at the tree scale during a single day. All traits differed among crown positions except the length-to-width ratio of the leaves. We found a strong complementarity in the patterns of the potential exposed area of the leaves among day periods as a result of a non-random distribution of leaf angles across the crown. Leaf exposure at the outer layer was below 60 % of the displayed surface, reaching maximum interception during morning periods. Daily interception increased towards the inner layer, achieving consecutive maximization from east to west positions within the crown, matching the sun's trajectory. The expression of leaf traits within isolated trees of O. europaea varies continuously through the crown in a gradient of leaf morphotypes and leaf angles depending on the exposure and location of individual leaves. The distribution of light-related traits within the crown and the complementarity in the potential exposure patterns of the leaves during the day challenges the assumption of low trait variability within individuals. © The Author 2016. Published by Oxford University Press on behalf of the Annals of

  18. A Reliability Generalization Study of the Marlowe-Crowne Social Desirability Scale.

    Science.gov (United States)

    Beretvas, S, Natasha; Meyers, Jason L.; Leite, Walter L.

    2002-01-01

    Conducted a reliability generalization study of the Marlowe-Crowne Social Desirability Scale (D. Crowne and D. Marlowe, 1960). Analysis of 93 studies show that the predicted score reliability for male adolescents was 0.53, and reliability for men's responses was lower than for women's. Discusses the need for further analysis of the scale. (SLD)

  19. Progress in radiation chemistry of crown ether extractants used for the solvent extraction of "9"0Sr

    International Nuclear Information System (INIS)

    Peng Jing; Yu Chuhong; Cui Zhenpeng; Zhai Maolin

    2011-01-01

    The separation of the long-lived fission products from dissolved nuclear fuel could improve the safe disposal of high-level nuclear wastes and reduce their threaten to human being and environment. Since the extractant system will be exposed to high radiation environment during the solvent extraction of long-lived fission products. The understanding of radiation chemistry of extractants is very important for practical design of extractant system. The radiation chemistry of crown ether systems proposed for use in the solvent extraction of one of fission products "9"0Sr were reviewed based on the study on the radiation stability and radiolysis mechanism of crown ether system. Finally some challenges were suggested. (authors)

  20. CORRELATION BETWEEN ANGIOTENSIN-CONVERTING ENZYME INHIBITORS LIPOPHILICITY AND PROTEIN BINDING DATA

    Directory of Open Access Journals (Sweden)

    Jasna Trbojević-Stanković

    2012-01-01

    Full Text Available Angiotensin-converting enzyme (ACE inhibitors represent a significant group of drugs primarily used in the treatment of hypertension and congestive heart failure. In this research, seven ACE inhibitors (enalapril, quinapril, fosinopril, lisinopril, cilazapril, ramipril, benazepril were studied to evaluate the relationship between their protein binding and calculated (logP values or ultra-high performance liquid chromatographytandem mass spectrometry (UHPLC-MS and reversed-phase thin-layer chromatography (RP-TLC lipophilicity data (ϕ0, CHI or C0 parameters, respectively. Their protein binding data varied from negligible (lisinopril to 99% (fosinopril, while calculated logPKOWWINvalues ranged from -0.94 (lisinopril to 6.61 (fosinopril. The good correlations were established between protein binding values and logPKOWWIN data (R2=0.7520 as well as between protein binding and chromatographic hydrophobicity data, ϕ0, CHI or C0parameters (R2 were 0.6160, 0.6242 and 0.6547, respectively. The possible application of hydrophobicity data in drugs protein binding evaluation can be of great importance in drug bioavailability.

  1. Cellular uptake of folate-conjugated lipophilic superparamagnetic iron oxide nanoparticles

    International Nuclear Information System (INIS)

    Woo, Kyoungja; Moon, Jihyung; Choi, Kyu-Sil; Seong, Tae-Yeon; Yoon, Kwon-Ha

    2009-01-01

    We prepared five folate-conjugated lipophilic superparamagnetic iron oxide nanoparticles (F 5 -Liposuperparamagnetic iron oxide nanoparticles(SPIONs), 5.5 and 11 nm) and investigated their cellular uptake with KB cells, which is one of the representative folate-receptor over-expressing human epidermoid carcinoma cells, using MRI. The cellular uptake tests with the respective 5.5 and 11 nm F 5 -LipoSPIONs at a fixed particle concentration showed appreciable amount of receptor-mediated uptakes and the specificity was higher in 5.5 nm SPIONs, due to its higher folic acid (FA) density, without inhibition. However, the numbers of the particles taken up under FA inhibition were similar, irrespective of their sizes.

  2. Electrochemical ion transfer mediated by a lipophilic Os(ii)/Os(iii) dinonyl bipyridyl probe incorporated in thin film membranes.

    Science.gov (United States)

    Jansod, Sutida; Wang, Lu; Cuartero, Maria; Bakker, Eric

    2017-09-28

    A new lipophilic dinonyl bipyridyl Os(ii)/Os(iii) complex successfully mediates ion transfer processes across voltammetric thin membranes. An added lipophilic cation-exchanger may impose voltammetric anion or cation transfer waves of Gaussian shape that are reversible and repeatable. The peak potential is found to shift with the ion concentration in agreement with the Nernst equation. The addition of tridodecylmethylammonium nitrate to the polymeric film dramatically reduces the peak separation from 240 mV to 65 mV, and the peak width to a near-theoretical value of 85 mV, which agrees with a surface confined process. It is suggested that the cationic additive serves as a phase transfer catalyst.

  3. Stochastic Mixed-Effects Parameters Bertalanffy Process, with Applications to Tree Crown Width Modeling

    Directory of Open Access Journals (Sweden)

    Petras Rupšys

    2015-01-01

    Full Text Available A stochastic modeling approach based on the Bertalanffy law gained interest due to its ability to produce more accurate results than the deterministic approaches. We examine tree crown width dynamic with the Bertalanffy type stochastic differential equation (SDE and mixed-effects parameters. In this study, we demonstrate how this simple model can be used to calculate predictions of crown width. We propose a parameter estimation method and computational guidelines. The primary goal of the study was to estimate the parameters by considering discrete sampling of the diameter at breast height and crown width and by using maximum likelihood procedure. Performance statistics for the crown width equation include statistical indexes and analysis of residuals. We use data provided by the Lithuanian National Forest Inventory from Scots pine trees to illustrate issues of our modeling technique. Comparison of the predicted crown width values of mixed-effects parameters model with those obtained using fixed-effects parameters model demonstrates the predictive power of the stochastic differential equations model with mixed-effects parameters. All results were implemented in a symbolic algebra system MAPLE.

  4. Tree crown structure indicators in a natural uneven-aged mixed coniferous forest in northeastern Mexico

    Science.gov (United States)

    Javier Jimenez-Perez; Oscar Aguirre-Calderon; Horst Kramer

    2006-01-01

    Characterization of tree crown structure provides critical information to assess a variety of ecological conditions for multiple purposes and applications. For biomass growth, for example, tree crowns have basic physiological functions: assimilation, respiration, and transpiration. How tree crowns spatially interact and grow can bring about a seamless landscape of...

  5. [Cervical adaptation of complete cast crowns of various metal alloys, with and without die spacers].

    Science.gov (United States)

    Stephano, C B; Roselino, R F; Roselino, R B; Campos, G M

    1989-01-01

    A metallic replica from a dental preparation for crown was used to make 8 class-IV stone dies. The wax patterns for the casting of the crowns were obtained in two conditions: a) from the stone die with no spacer; and b) from the stone die with an acrylic spacer. Thus, 64 metallic crowns were casted, using 4 different alloys: DURACAST (Cu-Al), NICROCAST (Ni-Cr) and DURABOND (Ni-Cr), and gold. The casted crowns were fitted in the metallic replica and measured as to the cervical discrepance of fitting. The results showed that the use of die spacers decreases the clinical discrepancies of fitting of the casted crowns (in a statistically significant level), no matter the metallic alloy employed.

  6. Wavelength selection in the crown splash

    Science.gov (United States)

    Zhang, Li V.; Brunet, Philippe; Eggers, Jens; Deegan, Robert D.

    2010-12-01

    The impact of a drop onto a liquid layer produces a splash that results from the ejection and dissolution of one or more liquid sheets, which expand radially from the point of impact. In the crown splash parameter regime, secondary droplets appear at fairly regularly spaced intervals along the rim of the sheet. By performing many experiments for the same parameter values, we measure the spectrum of small-amplitude perturbations growing on the rim. We show that for a range of parameters in the crown splash regime, the generation of secondary droplets results from a Rayleigh-Plateau instability of the rim, whose shape is almost cylindrical. In our theoretical calculation, we include the time dependence of the base state. The remaining irregularity of the pattern is explained by the finite width of the Rayleigh-Plateau dispersion relation. Alternative mechanisms, such as the Rayleigh-Taylor instability, can be excluded for the experimental parameters of our study.

  7. Scalpel Depigmentation and Surgical Crown Lengthening to ...

    African Journals Online (AJOL)

    level of the apices of the six maxillary anterior teeth. Maxillary canines and ... requires osseous resection surgeries whereas excessive gingival display due to ... this case included complete oral prophylaxis along aesthetic crown lengthening ...

  8. Reversed phase partition chromatographic separation of Gd(III) on poly(Crown Ether) column

    International Nuclear Information System (INIS)

    Mahanwar, K.R.; Sabale, S.R.

    2014-01-01

    A simple method has been developed for the separation of Gd(III) in hippuric acid medium by using poly(dibenzo-18-crown-6) as stationary phase. The effect of hippuric acid concentration, different eluting agent, foreign ions etc was studied and the optimum conditions were established. Breakthrough capacity of poly(dibenzo-18-crown-6) for Gd(III) was found to be 0.572 ±0.01 mmolg -1 of crown polymer. The separation of Gd(III) from other elements in multicomponent mixtures has been achieved. The method was extended for determination of Gd(III) in real sample. The method is simple, rapid and selective with good reproducibility (approximately ± 2%). Crown ethers are widely used as complexing agent that can selectively capture metal cation in their cavity. This special feature shown by poly (dibenzo-18-crown-6) has been used in our laboratory for selective cation exchanger by column chromatography. No attempts were made for the separation of Gd(III) using hippuric acid media and column chromatography. The present communication describes a simple and sensitive method for the determination of Gd(III) using poly(dibenzo-18-crown-6) as stationary phase in hippuric acid medium. The proposed method affords an attractive feature as compared to the solvent extraction technique i.e. it is free from any organic diluents as an environmental concern

  9. Fracture resistance of 3 types of primary esthetic stainless steel crowns.

    Science.gov (United States)

    Beattie, Sean; Taskonak, Burak; Jones, James; Chin, Judith; Sanders, Brian; Tomlin, Angela; Weddell, James

    2011-01-01

    Demand is increasing for esthetic restorations in pediatric dentistry. When full coverage is indicated, one option is to use esthetic stainless steel crowns (SSCs). However, this type of crown is prone to fracture. The purpose of this study was to evaluate the fracture resistance of 3 types of esthetic SSCs. Esthetic SSCs for first primary mandibular molars were cemented to idealized epoxy dies with glass ionomer cement. The die-crown units were fractured on a universal testing machine. The force was delivered by a stainless steel ball fixture, set in a uniaxial lever to replicate a cusp contact, with a crosshead speed of 1 mm/min. The differences among the 3 types of crown, in terms of force required to fracture, were compared statistically by 1-way analysis of variance. Pairwise comparisons were performed with Fisher's protected least significant difference test, at an overall significance level of 5%. The force required to fracture, expressed as average ± standard error, did not differ significantly among the 3 brands of esthetic SSCs: 1730 N ± 50 N, 1826 N ± 62 N and 1671 N ± 68 N, respectively (p = 0.19), well below the maximum bite force of pediatric patients determined in a previous study. Esthetic SSCs should be able to resist occlusal forces over short clinical periods. However, long-term occlusal loading and fatigue failures should be taken into account when evaluating the success of this type of crown.

  10. Relationship between crown placement and the survival of endodontically treated teeth.

    Science.gov (United States)

    Aquilino, Steven A; Caplan, Daniel J

    2002-03-01

    Crowns have been considered the restoration of choice for endodontically treated teeth, but their selection has been based primarily on anecdotal evidence. This study tested the hypothesis that crown placement (coronal coverage) is associated with improved survival of endodontically treated teeth when preaccess, endodontic, and restorative factors are controlled. A University of Iowa College of Dentistry treatment database was used to identify permanent teeth that had undergone initial obturation between July 1, 1985, and December 31, 1987. Study patients were restricted to persons with at least 1 dental visit in each 2-year interval from 1985 to 1996; a simple random sample of 280 patients (n = 400 teeth) was selected. Dental charts, radiographs, and computerized databases were examined to ascertain variables of interest and to verify study inclusion criteria. Kaplan-Meier survival estimates were generated for the 203 teeth that satisfied study inclusion criteria. Multivariate Cox proportional hazards regression models were developed, with standard errors adjusted to account for clustering of teeth within patients. When tooth type and radiographic evidence of caries at access were controlled, the final Cox model showed that endodontically treated teeth not crowned after obturation were lost at a 6.0 times greater rate than teeth crowned after obturation (95% confidence interval: 3.2 to 11.3). Within the limitations of this study, a strong association between crown placement and the survival of endodontically treated teeth was observed. These results may impact treatment planning if long-term tooth retention is the primary goal.

  11. Dental students' preferences and performance in crown design: conventional wax-added versus CAD.

    Science.gov (United States)

    Douglas, R Duane; Hopp, Christa D; Augustin, Marcus A

    2014-12-01

    The purpose of this study was to evaluate dental students' perceptions of traditional waxing vs. computer-aided crown design and to determine the effectiveness of either technique through comparative grading of the final products. On one of twoidentical tooth preparations, second-year students at one dental school fabricated a wax pattern for a full contour crown; on the second tooth preparation, the same students designed and fabricated an all-ceramic crown using computer-aided design (CAD) and computer-aided manufacturing (CAM) technology. Projects were graded for occlusion and anatomic form by three faculty members. On completion of the projects, 100 percent of the students (n=50) completed an eight-question, five-point Likert scalesurvey, designed to assess their perceptions of and learning associated with the two design techniques. The average grades for the crown design projects were 78.3 (CAD) and 79.1 (wax design). The mean numbers of occlusal contacts were 3.8 (CAD) and 2.9(wax design), which was significantly higher for CAD (p=0.02). The survey results indicated that students enjoyed designing afull contour crown using CAD as compared to using conventional wax techniques and spent less time designing the crown using CAD. From a learning perspective, students felt that they learned more about position and the size/strength of occlusal contacts using CAD. However, students recognized that CAD technology has limits in terms of representing anatomic contours and excursive occlusion compared to conventional wax techniques. The results suggest that crown design using CAD could be considered as an adjunct to conventional wax-added techniques in preclinical fixed prosthodontic curricula.

  12. 18-Crown-6-polyether complexing with iodine

    International Nuclear Information System (INIS)

    Borovikov, Yu.Ya.

    1988-01-01

    Using the methods of dielectrometry, conductometry, calorimetry, UV, NMR and IR spectroscopy, 18-Crown-6-polyether complexing with iodine in chlorobenzene, benzotrifluoride, 1,2 dichloroethane is investigated. At the first stage external complexes (1) of the composition 1:1 (dipole momentum μ=7 D) is formed, which gradually regroups into internal complex (2) of the compositon 4:1. The time of 1 transition into 2 is inversely proportional to dielectric permeability of the medium. Enthalpy of 1 formation is close to 8.3 kcal/mol, which is 2,5 times higher than in cyclohexane solutions. Complex 1 is molecular, 2 is salt-like. Formation enthalpy of complex 2 of the components is not high, in dichlaroethane it is centrally symmetric and nonpolar, in chlorobenzene and benzotrifluoride-highly polar. In solid phase complex of the composition 1:2 is formed

  13. 18-Crown-6-polyether complexing with iodine

    Energy Technology Data Exchange (ETDEWEB)

    Borovikov, Yu Ya [AN Ukrainskoj SSR, Kiev (Ukrainian SSR). Inst. Organicheskoj Khimii

    1988-01-01

    Using the methods of dielectrometry, conductometry, calorimetry, UV, NMR and IR spectroscopy, 18-Crown-6-polyether complexing with iodine in chlorobenzene, benzotrifluoride, 1,2 dichloroethane is investigated. At the first stage external complexes (1) of the composition 1:1 (dipole momentum {mu}=7 D) is formed, which gradually regroups into internal complex (2) of the compositon 4:1. The time of 1 transition into 2 is inversely proportional to dielectric permeability of the medium. Enthalpy of 1 formation is close to 8.3 kcal/mol, which is 2,5 times higher than in cyclohexane solutions. Complex 1 is molecular, 2 is salt-like. Formation enthalpy of complex 2 of the components is not high, in dichlaroethane it is centrally symmetric and nonpolar, in chlorobenzene and benzotrifluoride-highly polar. In solid phase complex of the composition 1:2 is formed.

  14. Effect of elasticity on stress distribution in CAD/CAM dental crowns: Glass ceramic vs. polymer-matrix composite.

    Science.gov (United States)

    Duan, Yuanyuan; Griggs, Jason A

    2015-06-01

    Further investigations are required to evaluate the mechanical behaviour of newly developed polymer-matrix composite (PMC) blocks for computer-aided design/computer-aided manufacturing (CAD/CAM) applications. The purpose of this study was to investigate the effect of elasticity on the stress distribution in dental crowns made of glass-ceramic and PMC materials using finite element (FE) analysis. Elastic constants of two materials were determined by ultrasonic pulse velocity using an acoustic thickness gauge. Three-dimensional solid models of a full-coverage dental crown on a first mandibular molar were generated based on X-ray micro-CT scanning images. A variety of load case-material property combinations were simulated and conducted using FE analysis. The first principal stress distribution in the crown and luting agent was plotted and analyzed. The glass-ceramic crown had stress concentrations on the occlusal surface surrounding the area of loading and the cemented surface underneath the area of loading, while the PMC crown had only stress concentration on the occlusal surface. The PMC crown had lower maximum stress than the glass-ceramic crown in all load cases, but this difference was not substantial when the loading had a lateral component. Eccentric loading did not substantially increase the maximum stress in the prosthesis. Both materials are resistant to fracture with physiological occlusal load. The PMC crown had lower maximum stress than the glass-ceramic crown, but the effect of a lateral loading component was more pronounced for a PMC crown than for a glass-ceramic crown. Knowledge of the stress distribution in dental crowns with low modulus of elasticity will aid clinicians in planning treatments that include such restorations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Explicit area-based accuracy assessment for mangrove tree crown delineation using Geographic Object-Based Image Analysis (GEOBIA)

    Science.gov (United States)

    Kamal, Muhammad; Johansen, Kasper

    2017-10-01

    Effective mangrove management requires spatially explicit information of mangrove tree crown map as a basis for ecosystem diversity study and health assessment. Accuracy assessment is an integral part of any mapping activities to measure the effectiveness of the classification approach. In geographic object-based image analysis (GEOBIA) the assessment of the geometric accuracy (shape, symmetry and location) of the created image objects from image segmentation is required. In this study we used an explicit area-based accuracy assessment to measure the degree of similarity between the results of the classification and reference data from different aspects, including overall quality (OQ), user's accuracy (UA), producer's accuracy (PA) and overall accuracy (OA). We developed a rule set to delineate the mangrove tree crown using WorldView-2 pan-sharpened image. The reference map was obtained by visual delineation of the mangrove tree crowns boundaries form a very high-spatial resolution aerial photograph (7.5cm pixel size). Ten random points with a 10 m radius circular buffer were created to calculate the area-based accuracy assessment. The resulting circular polygons were used to clip both the classified image objects and reference map for area comparisons. In this case, the area-based accuracy assessment resulted 64% and 68% for the OQ and OA, respectively. The overall quality of the calculation results shows the class-related area accuracy; which is the area of correctly classified as tree crowns was 64% out of the total area of tree crowns. On the other hand, the overall accuracy of 68% was calculated as the percentage of all correctly classified classes (tree crowns and canopy gaps) in comparison to the total class area (an entire image). Overall, the area-based accuracy assessment was simple to implement and easy to interpret. It also shows explicitly the omission and commission error variations of object boundary delineation with colour coded polygons.

  16. Does lipophilicity of toxic compounds determine effects on drought tolerance of the soil collembolan Folsomia candida?

    International Nuclear Information System (INIS)

    Skovlund, Gitte; Damgaard, Christian; Bayley, Mark; Holmstrup, Martin

    2006-01-01

    The ability of Collembola to survive drought stress is crucial for their distribution in the terrestrial environment. Previous studies have suggested that several toxic compounds affect the drought tolerance of Folsomia candida in a synergistic manner and that these compounds have the feature in common that they elicit their toxicity by causing membrane damage. We hypothesised that the detrimental effect of toxic chemicals on drought tolerance in F. candida depends on the lipophilicity (log K ow ) of the compound because a higher log K ow would mean a closer interaction with membranes. In this study the three chemicals 4-nonylphenol, pyrene and p,p'-DDE were tested. Surprisingly, 4-nonylphenol, with the lowest log K ow , was the most potent with respect to reducing drought tolerance followed by pyrene, suggesting that interactions between drought tolerance and chemical stress do not depend on lipophilicity alone. - Toxic stress may reduce drought tolerance of Collembola

  17. Application of biomimetic HPLC to estimate lipophilicity, protein and phospholipid binding of potential peptide therapeutics

    Directory of Open Access Journals (Sweden)

    Klara Livia Valko

    2018-06-01

    Full Text Available Peptide therapeutics are new modalities offering several challenges to drug discovery. They are generally less stable and permeable in vivo. The characterization of their lipophilicity cannot be carried out using the traditional in silico or wet octanol/water partition coefficients. The prediction of their in vivo distribution and permeability is also challenging. In this paper, it is demonstrated that the biomimetic properties such as lipophilicity, protein and phospholipid binding can be easily assessed by HPLC using chemically bonded protein and immobilized artificial membrane (IAM stationary phases. The obtained properties for a set of potential therapeutic peptides with 3 to 33 amino acids have been analysed and it was found that similar characteristics of the properties could be observed as for small molecule drugs. The albumin binding showed correlation with their measured lipophilicity on the C-18 stationary phase with acidic peptides showing stronger than expected albumin binding. The (IAM chromatography revealed peptide membrane affinity, which was stronger for positively charged peptides (containing arginine and showed correlation to the alpha-1-acid glycoprotein (AGP binding, which was also stronger for positively charged compounds. The in vivo volume of distribution and drug efficiency of the peptides have been estimated using the models developed for small molecules. One of the candidate linear peptides has been assessed in various cellular and in vivo assays and the results have confirmed the estimated cell partition and brain to plasma ratio. It can be demonstrated, that up to 21 amino acids, the peaks of the peptides obtained on the protein phase were symmetrical and narrow. The interaction of larger peptides with the protein stationary phases resulted in wide peaks showing multiple equilibrium processes with slow kinetics during chromatography. The larger peptides showed narrow and symmetrical peaks on the IAM column enabling

  18. Ten-year survival and complication rates of lithium-disilicate (Empress 2) tooth-supported crowns, implant-supported crowns, and fixed dental prostheses.

    Science.gov (United States)

    Teichmann, Maren; Göckler, Fabian; Weber, Volker; Yildirim, Murat; Wolfart, Stefan; Edelhoff, Daniel

    2017-01-01

    To prospectively evaluate the clinical long-term outcome of tooth-supported crowns (SCs), implant-supported crowns (ISCs), and fixed dental prostheses (FDPs) made of a lithium-disilicate glass-ceramic framework material (IPS Empress 2). Between 1997 and 1999, a total of 184 restorations (106 SCs, 32 ISCs, 33 FDPs, and 13 diverse restorations) were placed in 73 patients. Kaplan-Meier estimation was applied for survival and chipping-free rates. Inter-group comparison of both rates was realized by a log rank test and a 2×2 contingency table. Also, SCs and FDPs were compared regarding adhesive vs. conventional cementation, and anterior vs. posterior positioning, for impact on survival. Due to 14 dropouts (34 restorations) and reasonable exclusion of 19 other restorations, the final dataset included: i) 87 SCs [37 patients, mean observation time 11.4 (±3.8)years]; ii) 17 ISCs [12 patients, mean observation time 13.3 (±2.3)years; and iii) 27 FDPs [19 patients, mean observation time 8.9 (±5.4)years]. The 10-year survival rate/chipping-free rate for SCs were 86.1%/83.4%, for ISCs 93.8%/94.1%, and for FDPs were 51.9%/90.8%. Both ISCs and SCs had a significantly higher survival than FDPs (ISCs vs. FDPs: both tests p=0.001; SCs vs. FDPs: p=0.001 and p=0.005). Differences in the chipping-free rates did not reach significance. Also, neither the cementation mode nor positioning of the restoration had an impact on survival. SCs had a slightly lower outcome than can generally be expected from single crowns. In contrast, ICSs had a favorable outcome and the FDPs predominantly failed. The practitioner's choice of dental materials is based (at best) on long-term experience. The present 10-year results are based on comprehensive data analyses and show the high potential of lithium-disilicate as a reliable material, especially for single-unit restoration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Polyacrylonitrile (PAN)/crown ether composite nanofibers for the selective adsorption of cations

    NARCIS (Netherlands)

    Tas, Sinem; Kaynan, Ozge; Ozden-Yenigun, Elif; Nijmeijer, Dorothea C.

    2016-01-01

    In this study, we prepared electrospun polyacrylonitrile (PAN) nanofibers functionalized with dibenzo-18-crown-6 (DB18C6) crown ether and showed the potential of these fibers for the selective recovery of K+ from other both mono- and divalent ions in aqueous solutions. Nanofibers were characterized

  20. [Comparative study of microleakage by using different finished lines in selective laser melting metal crowns].

    Science.gov (United States)

    Peng, Yan; Zhong, Qun; Wu, Xue-Ying; Weng, Jia-Wei

    2016-12-01

    To evaluate microleakage of SLM Co -Cr alloy metal crown with two types finished line (chamfer and shoulder), compared with conventional fabrication of Co -Cr alloy metal crowns. Thirty healthy non-carious human molars were selected and randomly assigned to 3 groups, 10 in each. Teeth in group A and C received a chamfer finish line preparation, whereas teeth in group C received a shoulder finish line. Conventional Co -Cr alloy metal crowns were fabricated for group A when SLM metal crowns were made for group B and group C. Glass ionomer was applied for bonding. After 5000 thermocycles ranging from 5degrees centigrade to 55degrees centigrade,all the specimens were evaluated by dye penetration and then microleakage was examined under light microscope. The data were analyzed statistically with SPSS 20.0 software package. Microleakage in group A was significantly higher than the other two groups, group B and group C showed no significant difference in microleakage while microleakage in group B was higher than that in group C. Microleakage of SLM metal crowns was significantly less than that of conventional Co-Cr alloy metal crowns; chamfer finish line designs was recommended for SLM metal crowns in consideration of reducing microleakage and protecting tooth.

  1. Plastic collapse load of crown-hinged steel circular arches : a theoretical method

    NARCIS (Netherlands)

    Spoorenberg, R.C.; Snijder, H.H.; Hoenderkamp, J.C.D.

    2013-01-01

    For construction purposes and to avoid detrimental influences of foundation settlements arches are not always made from a single arch-rib but are built by connecting two curvilinear elements at the crown with a hinge. These arches are also known as crown-hinged arches. This paper presents an

  2. Modeling the spatial distribution of forest crown biomass and effects on fire behavior with FUEL3D and WFDS

    Science.gov (United States)

    Russell A. Parsons; William Mell; Peter McCauley

    2010-01-01

    Crown fire poses challenges to fire managers and can endanger fire fighters. Understanding of how fire interacts with tree crowns is essential to informed decisions about crown fire. Current operational crown fire predictions in the United States assume homogeneous crown fuels. While a new class of research fire models, which model fire behavior with computational...

  3. Modification chimique d'antioxydants pour les rendre lipophiles : application aux tannins

    OpenAIRE

    Poaty-Poaty , Bouddah

    2009-01-01

    Ce travail fut pour moi une expérience pétillante en dépit de l'énorme stress qu'il a occasionné. J'en tire une réelle satisfaction personnelle car cela est presque exclusivement le fruit de ma réflexion et de ma persévérance dans l'effort; In the order to use natural antioxidants in lipidic substances, we wanted to make lipophilic of tannins by grafting on them carbonaceous chains through mild and simple chemical modifications. First, we used model substrates of tannins (phenol, catechol, ga...

  4. Fracture resistance of metal-free composite crowns-effects of fiber reinforcement, thermal cycling, and cementation technique.

    Science.gov (United States)

    Lehmann, Franziska; Eickemeyer, Grit; Rammelsberg, Peter

    2004-09-01

    The improved mechanical properties of contemporary composites have resulted in their extensive use for the restoration of posterior teeth. However, the influence of fiber reinforcement, cementation technique, and physical stress on the fracture resistance of metal-free crowns is unknown. This in vitro study evaluated the effect of fiber reinforcement, physical stress, and cementation methods on the fracture resistance of posterior metal-free Sinfony crowns. Ninety-six extracted human third molars received a standardized tooth preparation: 0.5-mm chamfer preparation and occlusal reduction of 1.3 to 1.5 mm. Sinfony (nonreinforced crowns, n=48) and Sinfony-Vectris (reinforced crowns, n=48) crowns restoring original tooth contour were prepared. Twenty-four specimens of each crown type were cemented, using either glass ionomer cement (GIC) or resin cement. Thirty-two crowns (one third) were stored in humidity for 48 hours. Another third was exposed to 10,000 thermal cycles (TC) between 5 degrees C and 55 degrees C. The remaining third was treated with thermal cycling and mechanical loading (TCML), consisting of 1.2 million axial loads of 50 N. The artificial crowns were then vertically loaded with a steel sphere until failure occurred. Significant differences in fracture resistance (N) between experimental groups were assessed by nonparametric Mann-Whitney U-test (alpha=.05). Fifty percent of the Sinfony and Sinfony-Vectris crowns cemented with glass ionomer cement loosened after thermal cycling. Thermal cycling resulted in a significant reduction in the mean fracture resistance for Sinfony crowns cemented with GIC, from 2037 N to 1282 N (P=.004). Additional fatigue produced no further effects. Fiber reinforcement significantly increased fracture resistance, from 1555 N to 2326 N (P=.001). The minimal fracture resistance was above 600 N for all combinations of material, cement and loading. Fracture resistance of metal-free Sinfony crowns was significantly increased by

  5. Lower Cretaceous fossils from China shed light on the ancestral body plan of crown softshell turtles (Trionychidae, Cryptodira).

    Science.gov (United States)

    Brinkman, Donald; Rabi, Márton; Zhao, Lijun

    2017-07-27

    Pan-trionychids or softshell turtles are a highly specialized and widespread extant group of aquatic taxa with an evolutionary history that goes back to the Early Cretaceous. The earliest pan-trionychids had already fully developed the "classic" softshell turtle morphology and it has been impossible to resolve whether they are stem members of the family or are within the crown. This has hindered our understanding of the evolution of the two basic body plans of crown-trionychids. Thus it remains unclear whether the more heavily ossified shell of the cyclanorbines or the highly reduced trionychine morphotype is the ancestral condition for softshell turtles. A new pan-trionychid from the Early Cretaceous of Zhejiang, China, Perochelys hengshanensis sp. nov., allows a revision of softshell-turtle phylogeny. Equal character weighting resulted in a topology that is fundamentally inconsistent with molecular divergence date estimates of deeply nested extant species. In contrast, implied weighting retrieved Lower Cretaceous Perochelys spp. and Petrochelys kyrgyzensis as stem trionychids, which is fully consistent with their basal stratigraphic occurrence and an Aptian-Santonian molecular age estimate for crown-trionychids. These results indicate that the primitive morphology for soft-shell turtles is a poorly ossified shell like that of crown-trionychines and that shell re-ossification in cyclanorbines (including re-acquisition of peripheral elements) is secondary.

  6. A prospective study of the incidence of asymptomatic pulp necrosis following crown preparation.

    Science.gov (United States)

    Kontakiotis, E G; Filippatos, C G; Stefopoulos, S; Tzanetakis, G N

    2015-06-01

    To determine the incidence of asymptomatic pulp necrosis following crown preparation as well as the positive predictive value of the electric pulp testing. A total of 120 teeth with healthy pulps scheduled to receive fixed crowns (experimental teeth) were included. Teeth were divided into two groups according to the preoperative crown condition (intact teeth and teeth with preoperative caries, restorations or crowns) and into four groups according to tooth type (maxillary anterior teeth, maxillary posterior teeth, mandibular anterior teeth and mandibular posterior teeth). Experimental and control teeth were submitted to electric pulp testing on three different occasions before treatment commencement (stage 0), at the impression making session (stage 1) and just before the final cementation of the crown (stage 2). Teeth that were considered to contain necrotic pulps were submitted to root canal treatment. Upon access, absence of bleeding was considered as a confirmation of pulp necrosis. Data were analysed using bivariate (chi-square) and multivariate analysis (logistic regression). All reported probability values (P-values) were based on two-sided tests and compared to a significance level of 5%. The overall incidence of pulp necrosis was 9%. Intact teeth had a significantly lower incidence of pulp necrosis (5%) compared with preoperatively structurally compromised teeth (13%) [(OR: 9.113, P = 0.035)]. No significant differences were found amongst the four groups with regard to tooth type (P = 0.923). The positive predictive value of the electric pulp testing was 1.00. The incidence of asymptomatic pulp necrosis of teeth following crown preparation is noteworthy. The presence of preoperative caries, restorations or crowns of experimental teeth correlated with a significantly higher incidence of pulp necrosis. Electric pulp testing remains a useful diagnostic instrument for determining the pulp condition. © 2014 International Endodontic Journal. Published by

  7. In vitro analysis of the marginal adaptation and discrepancy of stainless steel crowns

    Science.gov (United States)

    Mulder, Riaan; Medhat, Rasha; Mohamed, Nadia

    2018-01-01

    Abstract Aim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC’s. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in accordance with the clinical technique. The ideal tooth preparation was made and this ‘master tooth’ duplicated to achieve a sample size of 15. The stainless steel crowns were placed, trimmed, and cemented as per the clinical technique. The cemented stainless crowns were analyzed under 100× stereomicroscope magnification. The marginal adaptation and discrepancy of each specimen was measured every 2 µm. Results: All the specimens showed marginal adaptation and discrepancy. The lingual margin had a significantly better adaptation (p steel crown adaptation and discrepancy is an essential clinical step. PMID:29536024

  8. 78 FR 63559 - Order of Suspension of Trading; In The Matter of Crown Alliance Capital Limited

    Science.gov (United States)

    2013-10-24

    ... Alliance Capital Limited (``Crown Alliance''), quoted under the ticker symbol CACL, because of questions regarding the accuracy of assertions in Crown Alliance's public filings concerning the company's assets and... of Crown Alliance Capital Limited October 22, 2013. It appears to the Securities and Exchange...

  9. Complexation between Methyl Viologen (Paraquat) Bis(Hexafluorophosphate) and Dibenzo[24]Crown-8 Revisited

    DEFF Research Database (Denmark)

    Gasa, Travis B.; Spruell, Jason M.; Dichtel, William R.

    2009-01-01

    Paraquat bis(hexafluorophosphate) undergoes stepwise dissociation in acetone. All three species - the neutral molecule, and the mono- and dications - are represented significantly under the experimental conditions typically used in host-guest binding studies. Paraquat forms at least four host...... toward dibenzo[24]crown-8. Thus, the relative abundance of neutral, singly, and doubly charged pseudorotaxanes is identical to the relative abundance of neutral, singly, and doubly charged paraquat unbound with respect to the crown ether in acetone. In the specific case of paraquat/dibenzo[24]crown-8...

  10. Effect of water temperature on the fit of provisional crown margins during polymerization: An in vitro study

    Directory of Open Access Journals (Sweden)

    Vivekanandan Ramkumar

    2012-01-01

    Full Text Available Aim: To evaluate the effect of water temperature on the marginal fit of bis-acrylic composite provisional crown during resin polymerization. Materials and Methods: Precisely machined 10 brass master dies were designed to simulate molar teeth. Five brass dies were selected and precisely machined to simulate all ceramic crown preparation. An acrylic jaw replica was made in which brass dies were arranged equidistant from each other. A custom-made metallic tray was fabricated on the acrylic jaw replica to make polyvinyl siloxane impression matrix. Bis-acrylic composite resin provisional crowns were made using polyvinyl siloxane impression matrix. Provisional crowns were polymerized at room temperature (Group I direct technique, on dental stone cast; Group I indirect technique crowns and at different water temperatures (Group II direct technique crowns. The vertical marginal gap between all the provisional crown margins and the finish line of brass dies was measured using a Research Stereomicroscope System. Results: The results were statistically analyzed using one-way analysis of variance (ANOVA test and Newman-Keul′s test. The results showed that crowns polymerized in 20°C and 30°C water had marginal gap approximately three times smaller than those polymerized in 30°C air, due to the reduced polymerization shrinkage. Conclusion: This study shows that crowns polymerized in 20°C and 30°C water had mean vertical marginal gap approximately three times smaller than those polymerized in 30°C air. It was approximately closer to that of crowns fabricated by indirect technique. Warmer water also supposedly hastens polymerization.

  11. Effect of water temperature on the fit of provisional crown margins during polymerization: An in vitro study.

    Science.gov (United States)

    Ramkumar, Vivekanandan; Sangeetha, Arunachalam; Kumar, Vinaya

    2012-08-01

    To evaluate the effect of water temperature on the marginal fit of bis-acrylic composite provisional crown during resin polymerization. Precisely machined 10 brass master dies were designed to simulate molar teeth. Five brass dies were selected and precisely machined to simulate all ceramic crown preparation. An acrylic jaw replica was made in which brass dies were arranged equidistant from each other. A custom-made metallic tray was fabricated on the acrylic jaw replica to make polyvinyl siloxane impression matrix. Bis-acrylic composite resin provisional crowns were made using polyvinyl siloxane impression matrix. Provisional crowns were polymerized at room temperature (Group I direct technique, on dental stone cast; Group I indirect technique crowns) and at different water temperatures (Group II direct technique crowns). The vertical marginal gap between all the provisional crown margins and the finish line of brass dies was measured using a Research Stereomicroscope System. The results were statistically analyzed using one-way analysis of variance (ANOVA) test and Newman-Keul's test. The results showed that crowns polymerized in 20°C and 30°C water had marginal gap approximately three times smaller than those polymerized in 30°C air, due to the reduced polymerization shrinkage. This study shows that crowns polymerized in 20°C and 30°C water had mean vertical marginal gap approximately three times smaller than those polymerized in 30°C air. It was approximately closer to that of crowns fabricated by indirect technique. Warmer water also supposedly hastens polymerization.

  12. Recent ground subsidence at Crown Road, Tauhara and its probable causes

    International Nuclear Information System (INIS)

    Bromley, Chris J.; Manville, Vern R.; Rosenberg, Michael D.; Currie, Steve

    2009-01-01

    A localised ground subsidence anomaly at Crown Road, Taupo, within the Tauhara field of the Wairakei-Tauhara geothermal system, has been subjected to intense scrutiny because of its relatively recent onset and proximity to urban areas. Over a period of 20 years a maximum of 0.63 m of subsidence has accumulated. Uncertainties regarding its cause remain, but the evidence now strongly favours a relatively shallow (about 50 m depth) origin, compared with other geothermal subsidence bowls at Wairakei, Tauhara and Ohaaki. Declining water levels in a shallow boiling aquifer are considered to be the principal driving mechanism at Crown Road. The source of the subsidence is an anomalously compressible formation of intensely altered ignimbrite found at the base of a buried hydrothermal eruption deposit. This formation is dominated by soft kaolinite and smectite-illite clays of high plasticity and water content, resulting from alteration of highly vesiculated pumice, and is capped by a thin hardpan of silicified pyroclastic material, characterised by vuggy macro-porosity, at about 33 m depth. During initiation of the subsidence event, this hardpan may have failed in shear mode around the edges of a buried eruption crater, allowing the overburden to fully load the underlying compressible clays. (author)

  13. Cellular uptake of folate-conjugated lipophilic superparamagnetic iron oxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Kyoungja [Nano-Materials Research Center, Korea Institute of Science and Technology, P. O. Box 131, Cheongryang, Seoul 130-650 (Korea, Republic of)], E-mail: kjwoo@kist.re.kr; Moon, Jihyung [Nano-Materials Research Center, Korea Institute of Science and Technology, P. O. Box 131, Cheongryang, Seoul 130-650 (Korea, Republic of); Department of Materials Science and Engineering, Korea University, 5-1, Anam-Dong, Sungbook-Ku, Seoul, 136-713 (Korea, Republic of); Choi, Kyu-Sil [Division of Molecular Imaging, Samsung Biomedical Research Institute, Samsung Medical Center, 50 Ilwon-Dong, Kangnam-Ku, Seoul 135-710 (Korea, Republic of); Seong, Tae-Yeon [Department of Materials Science and Engineering, Korea University, 5-1, Anam-Dong, Sungbook-Ku, Seoul, 136-713 (Korea, Republic of); Yoon, Kwon-Ha [Institute for Radiological Imaging Science, Wonkwang University School of Medicine, 344-2, Shinyong, Iksan, Jeonbuk 570-749 (Korea, Republic of)

    2009-05-15

    We prepared five folate-conjugated lipophilic superparamagnetic iron oxide nanoparticles (F{sub 5}-Liposuperparamagnetic iron oxide nanoparticles(SPIONs), 5.5 and 11 nm) and investigated their cellular uptake with KB cells, which is one of the representative folate-receptor over-expressing human epidermoid carcinoma cells, using MRI. The cellular uptake tests with the respective 5.5 and 11 nm F{sub 5}-LipoSPIONs at a fixed particle concentration showed appreciable amount of receptor-mediated uptakes and the specificity was higher in 5.5 nm SPIONs, due to its higher folic acid (FA) density, without inhibition. However, the numbers of the particles taken up under FA inhibition were similar, irrespective of their sizes.

  14. CROWN: A service grid middleware with trust management mechanism

    Institute of Scientific and Technical Information of China (English)

    HUAI Jinpeng; HU Chunming; LI Jianxin; SUN Hailong; WO Tianyu

    2006-01-01

    Based on a proposed Web service-based grid architecture, a service grid middleware system called CROWN is designed in this paper. As the two kernel points of the middleware, the overlay-based distributed grid resource management mechanism is proposed, and the policy-based distributed access control mechanism with the capability of automatic negotiation of the access control policy and trust management and negotiation is also discussed in this paper. Experience of CROWN testbed deployment and application development shows that the middleware can support the typical scenarios such as computing-intensive applications, data-intensive applications and mass information processing applications.

  15. Descriptive statistics of tree crown condition in the Southern United States and impacts on data analysis and interpretation

    Science.gov (United States)

    KaDonna C. Randolph

    2006-01-01

    The U.S. Department of Agriculture Forest Service, Forest Inventory and Analysis Program (FIA) utilizes visual assessments of tree crown condition to monitor changes and trends in forest health. This report describes and discusses distributions of three FIA crown condition indicators (crown density, crown dieback, and foliage transparency) for trees in the Southern...

  16. Radiochemical determination of 210Pb using crown ether

    International Nuclear Information System (INIS)

    Vajda, N.; Bodizs, D.; Vodicska, M.

    1994-01-01

    Gamma spectrometric determination of 210 Pb following chemical separation has been performed very precisely and with high sensitivity, due to the low and constant self-absorption of the chemically pure sample. A simple and quick method for the chemical separation of lead using crown ether has been developed. Its four steps are described in detail. The new method was verified using phosphate ore and gypsum samples that were measured in an interlaboratory comparison and with a standard reference material. This method can also be used for self-absorption correction in direct gamma spectrometry of 210 Pb. (N.T.) 4 refs.; 2 figs.; 2 tabs

  17. Stability constants for some divalent metal ion/crown ether complexes in methanol determined by polarography and conductometry

    NARCIS (Netherlands)

    Chen, L.; Bos, M.; Grootenhuis, P.D.J.; Christenhusz, A.; Hoogendam, E.; Reinhoudt, David; van der Linden, W.E.

    1987-01-01

    Stability constants in methanol at 25.0°C were evaluated for the complexes of the divalent cations Ca2+, Ni2+, Zn2+, Pb2+, Mg2+, Co2+ and Cu2+ with the macrocyclic polyethers 15-crown-5 (15C5), 18-crown-6 (18C6), dicyclohexyl-18-crown-6 (DC18C6) and dibenzo-24-crown-8 (DB24C8). The log K values of

  18. Lipophilic Fraction of Cultivated Bifurcaria bifurcata R. Ross: Detailed Composition and In Vitro Prospection of Current Challenging Bioactive Properties

    Directory of Open Access Journals (Sweden)

    Sónia A. O. Santos

    2017-11-01

    Full Text Available Macroalgae have been seen as an alternative source of molecules with promising bioactivities to use in the prevention and treatment of current lifestyle diseases. In this vein, the lipophilic fraction of short-term (three weeks cultivated Bifurcaria bifurcata was characterized in detail by gas chromatography–mass spectrometry (GC-MS. B. bifurcata dichloromethane extract was composed mainly by diterpenes (1892.78 ± 133.97 mg kg−1 dry weight (DW, followed by fatty acids, both saturated (550.35 ± 15.67 mg kg−1 DW and unsaturated (397.06 ± 18.44 mg kg−1 DW. Considerable amounts of sterols, namely fucosterol (317.68 ± 26.11 mg kg−1 DW were also found. In vitro tests demonstrated that the B. bifurcata lipophilic extract show antioxidant, anti-inflammatory and antibacterial activities (against both Gram-positive and Gram-negative bacteria, using low extract concentrations (in the order of µg mL−1. Enhancement of antibiotic activity of drug families of major clinical importance was observed by the use of B. bifurcata extract. This enhancement of antibiotic activity depends on the microbial strain and on the antibiotic. This work represents the first detailed phytochemical study of the lipophilic extract of B. bifurcata and is, therefore, an important contribution for the valorization of B. bifurcata macroalgae, with promising applications in functional foods, nutraceutical, cosmetic and biomedical fields.

  19. Lipophilic Fraction of Cultivated Bifurcaria bifurcata R. Ross: Detailed Composition and In Vitro Prospection of Current Challenging Bioactive Properties.

    Science.gov (United States)

    Santos, Sónia A O; Trindade, Stephanie S; Oliveira, Catia S D; Parreira, Paula; Rosa, Daniela; Duarte, Maria F; Ferreira, Isabel; Cruz, Maria T; Rego, Andreia M; Abreu, Maria H; Rocha, Silvia M; Silvestre, Armando J D

    2017-11-01

    Macroalgae have been seen as an alternative source of molecules with promising bioactivities to use in the prevention and treatment of current lifestyle diseases. In this vein, the lipophilic fraction of short-term (three weeks) cultivated Bifurcaria bifurcata was characterized in detail by gas chromatography-mass spectrometry (GC-MS). B. bifurcata dichloromethane extract was composed mainly by diterpenes (1892.78 ± 133.97 mg kg -1 dry weight (DW)), followed by fatty acids, both saturated (550.35 ± 15.67 mg kg -1 DW) and unsaturated (397.06 ± 18.44 mg kg -1 DW). Considerable amounts of sterols, namely fucosterol (317.68 ± 26.11 mg kg -1 DW) were also found. In vitro tests demonstrated that the B. bifurcata lipophilic extract show antioxidant, anti-inflammatory and antibacterial activities (against both Gram-positive and Gram-negative bacteria), using low extract concentrations (in the order of µg mL -1 ). Enhancement of antibiotic activity of drug families of major clinical importance was observed by the use of B. bifurcata extract. This enhancement of antibiotic activity depends on the microbial strain and on the antibiotic. This work represents the first detailed phytochemical study of the lipophilic extract of B. bifurcata and is, therefore, an important contribution for the valorization of B. bifurcata macroalgae, with promising applications in functional foods, nutraceutical, cosmetic and biomedical fields.

  20. In vitro evaluation of the marginal fit of different all-ceramic crowns

    Directory of Open Access Journals (Sweden)

    Munir Tolga Yucel

    2013-09-01

    Conclusion: In-Ceram all-ceramic crowns showed the largest marginal gap, and Celay crowns showed the smallest marginal gap in both die groups. The marginal discrepancies found in this study were all within the clinically acceptable standard of 120 μm.

  1. An investigation of heat transfer to the implant-bone interface when drilling through a zirconia crown attached to a titanium or zirconia abutment.

    Science.gov (United States)

    Mason, Amy G; Sutton, Alan; Turkyilmaz, Ilser

    2014-11-01

    Thermal injury to the implant-bone interface may lead to bone necrosis and loss of osseointegration. This is a concern during manipulation of the implant throughout the restorative phase of treatment. The risk of heat transfer to the implant-bone interface during abutment preparation or prosthesis removal should be considered. The purpose of the study was to examine the amount of heat transferred to the implant-bone interface when a zirconia crown is drilled to access the screw channel or section a crown with a high-speed dental handpiece. Of the 64 ceramic-veneered zirconia crowns fabricated, 32 had a coping thickness of 0.5 mm and 32 had a coping thickness of 1.0 mm. The crowns were cemented on either titanium stock abutments or zirconia stock abutments. Each group was further subdivided to evaluate heat transfer when the screw channel was accessed or the crown was sectioned with a high-speed handpiece with or without irrigation. Temperature change was recorded for each specimen at the cervical and apical aspect of the implant with thermocouples and a logging thermometer. ANOVA was used to assess the statistical significance in temperature change between the test combinations, and nonparametric Mann-Whitney U tests were used to evaluate the findings. The use of irrigation during both crown removal processes yielded an average temperature increase of 3.59 ±0.35°C. Crown removal in the absence of irrigation yielded an average temperature increase of 18.76 ±3.09°C. When all parameter combinations in the presence of irrigation were evaluated, the maximum temperature change was below the threshold of thermal injury to bone. The maximum temperature change was above the threshold for thermal injury at the coronal aspect of the implant and below the threshold at the apical aspect in the absence of irrigation. Within the limitations of this investigation, the use of irrigation with a high-speed dental handpiece to remove a ceramic-veneered zirconia crown results in

  2. Analysis of lipophilic marine biotoxins by liquid chromatography coupled with high-resolution mass spectrometry in seawater from the Catalan Coast.

    Science.gov (United States)

    Bosch-Orea, Cristina; Sanchís, Josep; Farré, Marinella; Barceló, Damià

    2017-09-01

    Marine biotoxins regularly occur along the coast, with several consequences for the environment as well as the food industry. Monitoring of these compounds in seawater is required to assure the safety of marine resources for human consumption, providing a means for forecasting shellfish contamination events. In this study, an analytical method was developed for the detection of ten lipophilic marine biotoxins in seawater: azaspiracids 1, 2, 3, 4 and 5, classified as azaspiracid shellfish poisoning toxins, and pectenotoxin 2, okadaic acid and the related dinophysistoxin 1, yessotoxin and homoyessotoxin, classified as diarrheic shellfish poisoning toxins. The method is based on the application of solid-liquid ultrasound-assisted extraction and solid-phase extraction, followed by high-performance liquid chromatography coupled with high-resolution mass spectrometry. The limits of detection of this method are in the range of nanograms per litre and picograms per litre for most of the compounds, and recoveries range from 20.5% to 97.2%. To validate the effectiveness of this method, 36 samples of surface water from open coastal areas and marinas located along the Catalan coast on the Mediterranean Sea were collected and analysed. Eighty-eight per cent of these samples exhibited okadaic acid in particulate and aqueous phases in concentrations ranging from 0.11 to 560 μg/g and from 2.1 to 1780 ng/L respectively. Samples from open coastal areas exhibited higher concentrations of okadaic acid in particulate material, whereas in samples collected in sportive ports, the particulate material exhibited lower levels than the aqueous phase. Graphical Abstract Biotoxins investigated in seawater of the Catalan coast.

  3. Crown-root morphology of lower incisors in patients with class III malocclusion.

    Science.gov (United States)

    Wang, Bo; Shen, Guofang; Fang, Bing; Zhang, Li

    2012-07-01

    The purpose of this study was to investigate the crown-root morphology of lower incisors in patients with class III malocclusion using cone-beam computed tomography. Cone-beam computed tomography images were analyzed from 53 adult class I patients (group 1), 37 preadolescent class III patients (group 2), and 66 adult class III patients (group 3) comprising 3 divisions (divisions 1, 2, and 3 corresponded to mild, moderate, and severe class III malocclusions). The size and crown-root angulations of lower incisors in different groups and divisions were statistically appraised with group 1 used as the control group. No significant differences were found for the size of lower incisors among different groups and divisions (P > 0.05). Compared with group 1, the crown-root angulations of lower incisors in groups 2 and 3 were significantly larger (P lower incisors of division 3 rather than divisions 2 and 3 exhibited larger crown-root angulations (P lower incisors in class III patients during orthodontic and orthognathic treatment, especially in severe ones.

  4. Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

    Science.gov (United States)

    Tulapornchai, Chantana; Mamani, Jatuphol; Kamchatphai, Wannaporn; Thongpun, Noparat

    2013-01-01

    PURPOSE The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS Twenty one posterior zirconia crowns were made for twenty subjects. Seven premolar crowns and six molar crowns were cemented onto abutments with metal post and core in the first and second group. In the third group, eight molar crowns were cemented onto abutments with a prefabricated post and composite core build-up. The color measurements of all-ceramic crowns were made before try-in, before and after cementation. A repeated measure ANOVA was used for a statistical analysis of a color change of all-ceramic crowns at α=.05. Twenty four zirconia specimens, with different core thicknesses (0.4-1 mm) were also prepared to obtain the contrast ratio of zirconia materials after veneering. RESULTS L*, a*, and b* values of all-ceramic crowns cemented either on a metal cast post and core or on a prefabricated post did not show significant changes (P>.05). However, the slight color changes of zirconia crowns were detected and represented by ΔE*ab values, ranging from 1.2 to 3.1. The contrast ratios of zirconia specimens were 0.92-0.95 after veneering. CONCLUSION No significant differences were observed between the L*, a*, and b* values of zirconia crowns cemented either on a metal cast post and core or a prefabricated post and composite core. However, the color of a background substructure could affect the overall color of posterior zirconia restorations with clinically recommended core thickness according to ΔE*ab values. PMID:24049574

  5. Comparison of Amount of Primary Tooth Reduction Required for Anterior and Posterior Zirconia and Stainless Steel Crowns.

    Science.gov (United States)

    Clark, Larkin; Wells, Martha H; Harris, Edward F; Lou, Jennifer

    2016-01-01

    To determine if aggressiveness of primary tooth preparation varied among different brands of zirconia and stainless steel (SSC) crowns. One hundred primary typodont teeth were divided into five groups (10 posterior and 10 anterior) and assigned to: Cheng Crowns (CC); EZ Pedo (EZP); Kinder Krowns (KKZ); NuSmile (NSZ); and SSC. Teeth were prepared, and assigned crowns were fitted. Teeth were weighed prior to and after preparation. Weight changes served as a surrogate measure of tooth reduction. Analysis of variance showed a significant difference in tooth reduction among brand/type for both the anterior and posterior. Tukey's honest significant difference test (HSD), when applied to anterior data, revealed that SSCs required significantly less tooth removal compared to the composite of the four zirconia brands, which showed no significant difference among them. Tukey's HSD test, applied to posterior data, revealed that CC required significantly greater removal of crown structure, while EZP, KKZ, and NSZ were statistically equivalent, and SSCs required significantly less removal. Zirconia crowns required more tooth reduction than stainless steel crowns for primary anterior and posterior teeth. Tooth reduction for anterior zirconia crowns was equivalent among brands. For posterior teeth, reduction for three brands (EZ Pedo, Kinder Krowns, NuSmile) did not differ, while Cheng Crowns required more reduction.

  6. Greyish shadow on the labial gingival margin after insertion porcelain fused to metal crown on anterior teeth

    Directory of Open Access Journals (Sweden)

    Ike Damayanti Habar

    2016-06-01

    Full Text Available The crown is the type of restoration that replaces lost tooth structure caused by caries, trauma, or other causes which aims to restore comfort, function and patient confidence. Porcelain fused to metal restorationis an option that dominate the aesthetic restoration crown sand fixed prosthesisover the last 50 years. Porcelain fused to metal crown, consists of porcelain layer bonded to a thin cast metal coping that fits over the tooth preparation. Such a restoration combines the strength  and accurate fit of a cast metal crown with  the cosmetic effect of a porcelain crown. In some cases, it looks greyish shadow on the labial gingival margin after insertion porcelain fused to metal crowns on anterior teeth that can not be hidden even if the placement of the edge in subgingival. The purpose of this case report is to determine the cause of a greyish shadow on the labial gingival margin after insertion porcelain fused to metal crowns on anterior teeth and how to prevent a greyish shadow very disturbing aesthetics of the patient.

  7. Distribution of Lepidopteran Larvae on Norway Spruce: Effects of Slope and Crown Aspect.

    Science.gov (United States)

    Kulfan, Ján; Dvořáčková, Katarína; Zach, Peter; Parák, Michal; Svitok, Marek

    2016-04-01

    Lepidoptera associated with Norway spruce, Picea abies (L.) Karsten, play important roles in ecosystem processes, acting as plant pests, prey for predators, and hosts for parasites and parasitoids. Their distribution patterns in spruce crowns and forests are only poorly understood. We examined how slope and crown aspect affect the occurrence and abundance of moth larvae on solitary spruce trees in a montane region in Central Europe. Moth larvae were collected from southern and northern crowns of trees growing on south- and north-facing slopes (four treatments) using emergence boxes at the end of winter and by the beating method during the growing season. Species responses to slope and crown aspect were not uniform. Treatment effects on moth larvae were stronger in the winter than during the growing season. In winter, the abundance of bud-boring larvae was significantly higher in northern than in southern crowns regardless of the slope aspect, while both slope and aspect had marginally significant effects on abundance of miners. During the growing season, the occurrence of free-living larvae was similar among treatments. Emergence boxes and beating spruce branches are complementary techniques providing valuable insights into the assemblage structure of moth larvae on Norway spruce. Due to the uneven distribution of larvae detected in this study, we recommend adoption of a protocol that explicitly includes sampling of trees from contrasting slopes and branches from contrasting crown aspect in all seasons. © The Authors 2016. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Marginal Fit of Lithium Disilicate Crowns Fabricated Using Conventional and Digital Methodology: A Three-Dimensional Analysis.

    Science.gov (United States)

    Mostafa, Nezrine Z; Ruse, N Dorin; Ford, Nancy L; Carvalho, Ricardo M; Wyatt, Chris C L

    2018-02-01

    To compare the marginal fit of lithium disilicate (LD) crowns fabricated with digital impression and manufacturing (DD), digital impression and traditional pressed manufacturing (DP), and traditional impression and manufacturing (TP). Tooth #15 was prepared for all-ceramic crowns on an ivorine typodont. There were 45 LD crowns fabricated using three techniques: DD, DP, and TP. Microcomputed tomography (micro-CT) was used to assess the 2D and 3D marginal fit of crowns in all three groups. The 2D vertical marginal gap (MG) measurements were done at 20 systematically selected points/crown, while the 3D measurements represented the 3D volume of the gap measured circumferentially at the crown margin. Frequencies of different marginal discrepancies were also recorded, including overextension (OE), underextension (UE), and marginal chipping. Crowns with vertical MG > 120 μm at more than five points were considered unacceptable and were rejected. The results were analyzed by one-way ANOVA with Scheffe post hoc test (α = 0.05). DD crowns demonstrated significantly smaller mean vertical MG (33.3 ± 19.99 μm) compared to DP (54.08 ± 32.34 μm) and TP (51.88 ± 35.34 μm) crowns. Similarly, MG volume was significantly lower in the DD group (3.32 ± 0.58 mm 3 ) compared to TP group (4.16 ± 0.59 mm 3 ). The mean MG volume for the DP group (3.55 ± 0.78 mm 3 ) was not significantly different from the other groups. The occurrence of underextension error was higher in DP (6.25%) and TP (5.4%) than in DD (0.33%) group, while overextension was more frequent in DD (37.67%) than in TP (28.85%) and DP (18.75%) groups. Overall, 4 out of 45 crowns fabricated were deemed unacceptable based on the vertical MG measurements (three in TP group and one in DP group; all crowns in DD group were deemed acceptable). The results suggested that digital impression and CAD/CAM technology is a suitable, better alternative to traditional impression and manufacturing. © 2017 by the American College

  9. Study on toxicity mutation of crown-vetch induced by radiation

    International Nuclear Information System (INIS)

    Yi Huying; Yu Hongbin; Ma Jianzong

    1992-01-01

    The suckers of Germany crown-vetch were irradiated by 60 Co gamma ray and fast neutron. The toxicity mutation frequency and genetic stability of crown-vetch were studied. The various toxicity mutants were found in M 1 . Most of the toxicity mutants was unstable in M 2 , Stable mutant was very few (about 2.0-12.9%). β-nitropropionic acid in the low toxicity mutants selected was 31.7-39.8 mg/g. Genetic characteristics of low toxicity mutants were stable in M 3 -M 5

  10. Paraphoma crown rot of pyrethrum (Tanacetum cinerariifolium)

    NARCIS (Netherlands)

    Moslemi, Azin; Ades, Peter Kevin; Groom, Tim; Crous, Pedro; Nicolas, Marc Edward; Taylor, Paul William James

    2016-01-01

    Pyrethrum (Tanacetum cinerariifolium) is commercially cultivated for the extraction of natural pyrethrin insecticides from the oil glands inside seeds. Yield-decline has caused significant yield losses in Tasmania during the last decade. A new pathogen of pyrethrum causing crown rot and reduced

  11. Laser all-ceramic crown removal and pulpal temperature--a laboratory proof-of-principle study.

    Science.gov (United States)

    Rechmann, P; Buu, N C H; Rechmann, B M T; Finzen, F C

    2015-11-01

    The objective of this proof-of-principle laboratory pilot study was to evaluate the temperature increase in the pulp chamber in a worst case scenario during Er:YAG laser debonding of all-ceramic crowns. Twenty extracted molars were prepared to receive all-ceramic IPS E.max CAD full contour crowns. The crowns were bonded to the teeth with Ivoclar Multilink Automix. Times for laser debonding and temperature rise in the pulp chamber using micro-thermocouples were measured. The Er:YAG was used with 560 mJ/pulse. The irradiation was applied at a distance of 5 mm from the crown surface. Additional air-water spray for cooling was utilized. Each all-ceramic crown was successfully laser debonded with an average debonding time of 135 ± 35 s. No crown fractured, and no damage to the underlying dentin was detected. The bonding cement deteriorated, but no carbonization at the dentin/cement interface occurred. The temperature rise in the pulp chamber averaged 5.4° ± 2.2 °C. During 8 out of the 20 crown removals, the temperature rise exceeded 5.5 °C, lasting 5 to 43 s (average 18.8 ± 11.6 s). A temperature rise of 11.5 °C occurred only once, while seven times the temperature rise was limited to 6.8 ± 0.5 °C. Temperature rises above 5.5 °C occurred only when the laser was applied from one side and additional cooling from the side opposite the irradiation. Er:YAG laser energy can successfully be used to efficiently debond all-ceramic crowns from natural teeth. Temperature rises exceeding 5.5 °C only occur when an additional air/water cooling from a dental syringe is inaccurately directed. To avoid possible thermal damage and to allow further heat diffusion, clinically temperature-reduced water might be applied.

  12. Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions

    Science.gov (United States)

    Yang, Xin; Lv, Pin; Liu, Yihong; Si, Wenjie; Feng, Hailan

    2015-01-01

    In this study, the accuracy (precision and trueness) of digital impressions and the fitness of single crowns manufactured based on digital impressions were evaluated. #14-17 epoxy resin dentitions were made, while full-crown preparations of extracted natural teeth were embedded at #16. (1) To assess precision, deviations among repeated scan models made by intraoral scanner TRIOS and MHT and model scanner D700 and inEos were calculated through best-fit algorithm and three-dimensional (3D) comparison. Root mean square (RMS) and color-coded difference images were offered. (2) To assess trueness, micro computed tomography (micro-CT) was used to get the reference model (REF). Deviations between REF and repeated scan models (from (1)) were calculated. (3) To assess fitness, single crowns were manufactured based on TRIOS, MHT, D700 and inEos scan models. The adhesive gaps were evaluated under stereomicroscope after cross-sectioned. Digital impressions showed lower precision and better trueness. Except for MHT, the means of RMS for precision were lower than 10 μm. Digital impressions showed better internal fitness. Fitness of single crowns based on digital impressions was up to clinical standard. Digital impressions could be an alternative method for single crowns manufacturing. PMID:28793417

  13. Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions

    Directory of Open Access Journals (Sweden)

    Xin Yang

    2015-06-01

    Full Text Available In this study, the accuracy (precision and trueness of digital impressions and the fitness of single crowns manufactured based on digital impressions were evaluated. #14-17 epoxy resin dentitions were made, while full-crown preparations of extracted natural teeth were embedded at #16. (1 To assess precision, deviations among repeated scan models made by intraoral scanner TRIOS and MHT and model scanner D700 and inEos were calculated through best-fit algorithm and three-dimensional (3D comparison. Root mean square (RMS and color-coded difference images were offered. (2 To assess trueness, micro computed tomography (micro-CT was used to get the reference model (REF. Deviations between REF and repeated scan models (from (1 were calculated. (3 To assess fitness, single crowns were manufactured based on TRIOS, MHT, D700 and inEos scan models. The adhesive gaps were evaluated under stereomicroscope after cross-sectioned. Digital impressions showed lower precision and better trueness. Except for MHT, the means of RMS for precision were lower than 10 μm. Digital impressions showed better internal fitness. Fitness of single crowns based on digital impressions was up to clinical standard. Digital impressions could be an alternative method for single crowns manufacturing.

  14. Contribution to the standardization of the chromatographic conditions for the lipophilicity assessment of neutral and basic drugs

    Energy Technology Data Exchange (ETDEWEB)

    Giaginis, Costas [Department of Pharmaceutical Chemistry, School of Pharmacy, University of Athens, Panepistimiopolis, Zografou, Athens 15771 (Greece); Department of Forensic Medicine and Toxicology, Medical School, University of Athens, 75 Mikras Asias Street, Athens 11527 (Greece); Theocharis, Stamatios [Department of Forensic Medicine and Toxicology, Medical School, University of Athens, 75 Mikras Asias Street, Athens 11527 (Greece); Tsantili-Kakoulidou, Anna [Department of Pharmaceutical Chemistry, School of Pharmacy, University of Athens, Panepistimiopolis, Zografou, Athens 15771 (Greece)]. E-mail: tsantili@pharm.uoa.gr

    2006-07-28

    The chromatographic conditions aiming to a better simulation of n-octanol-water partitioning using a base deactivated silica (BDS) column as stationary phase were investigated for structurally diverse basic and neutral drugs. Extrapolated retention factors log k{sub w}, determined using different methanol fractions as organic modifier, were considered as lipophilicity indices. The effect of n-decylamine and n-octanol as mobile phase additives was examined and the appropriateness of the final retention outcome to reproduce lipophilicity data was evaluated. Moreover, the influence of n-octanol on the linearity of the log k/methanol fraction relationship and on the uniformity of the retention mechanism was investigated. 1:1 correlation between log k{sub w} values and the logarithm of the distribution coefficient (log D) was established for basic drugs in presence of both n-decylamine and n-octanol as mobile phase additives. However, for neutral drugs n-decylamine proved to be a sufficient and more important factor than n-octanol.

  15. Contribution to the standardization of the chromatographic conditions for the lipophilicity assessment of neutral and basic drugs

    International Nuclear Information System (INIS)

    Giaginis, Costas; Theocharis, Stamatios; Tsantili-Kakoulidou, Anna

    2006-01-01

    The chromatographic conditions aiming to a better simulation of n-octanol-water partitioning using a base deactivated silica (BDS) column as stationary phase were investigated for structurally diverse basic and neutral drugs. Extrapolated retention factors log k w , determined using different methanol fractions as organic modifier, were considered as lipophilicity indices. The effect of n-decylamine and n-octanol as mobile phase additives was examined and the appropriateness of the final retention outcome to reproduce lipophilicity data was evaluated. Moreover, the influence of n-octanol on the linearity of the log k/methanol fraction relationship and on the uniformity of the retention mechanism was investigated. 1:1 correlation between log k w values and the logarithm of the distribution coefficient (log D) was established for basic drugs in presence of both n-decylamine and n-octanol as mobile phase additives. However, for neutral drugs n-decylamine proved to be a sufficient and more important factor than n-octanol

  16. The Formation and Maintenance of the Dominant Southern Polar Crown Cavity of Cycle 24

    Energy Technology Data Exchange (ETDEWEB)

    Karna, N.; Pesnell, W. D. [NASA Goddard Space Flight Center, Greenbelt, MD (United States); Zhang, J. [George Mason University, Fairfax, VA (United States)

    2017-02-01

    In this article, we report a study of the longest-lived polar crown cavity of Solar Cycle 24, using an observation from 2013, and propose a physical mechanism to explain its sustained existence. We used high temporal and spatial resolution observations from the Atmospheric Imaging Assembly (AIA) and the Helioseismic Magnetic Imager (HMI) instruments on board the Solar Dynamics Observatory ( SDO ) to explore the structure and evolution of the cavity. Although it existed for more than a year, we examined the circumpolar cavity in great detail from 2013 March 21 to 2013 October 31. Our study reinforces the existing theory of formation of polar crown filaments that involves two basic processes to form any polar crown cavity as well as the long-lived cavity that we studied here. First, the underlying polarity inversion line (PIL) of the circumpolar cavity is formed between (1) the trailing part of dozens of decayed active regions distributed in different longitudes and (2) the unipolar magnetic field in the polar coronal hole. Second, the long life of the cavity is sustained by the continuing flux cancellation along the PIL. The flux is persistently transported toward the polar region through surface meridional flow and diffusion. The continuing flux cancellation leads to the shrinking of the polar coronal hole.

  17. Standing intraoral extractions of cheek teeth aided by partial crown removal in 165 horses (2010-2016).

    Science.gov (United States)

    Rice, M K; Henry, T J

    2018-01-01

    Diseased cheek teeth in horses often require invasive extraction techniques that carry a high rate of complications. Techniques and instrumentation were developed to perform partial crown removal to aid standing intraoral extraction of diseased cheek teeth in horses. To analyse success rates and post-surgical complications in horses undergoing cheek teeth extraction assisted by partial crown removal. Retrospective cohort study. This study included 165 horses with 194 diseased cheek teeth that were extracted orally assisted by partial crown removal between 2010 and 2016. Medical records were analysed, including case details, obtained radiographs, surgical reports and follow-up information. Follow-up information (≥2 months) was obtained for 151 horses (91.5%). There were 95 horses examined post-operatively by the authors and, 16 horses by the referring veterinarian; in 40 horses, post-operative follow up was obtained by informal telephone interviews with the owner. Successful standing intraoral extraction of cheek teeth was obtained in 164/165 horses (99.4%). Twenty-five of these horses (15.2%) required additional intraoral extraction methods to complete the extraction, including minimally invasive transbuccal approach (n = 21) and tooth sectioning (n = 4). There was one (0.6%) horse with intraoral extraction failure that required standing repulsion to complete the extraction. The intraoperative complication of fractured root tips occurred in 11/165 horses (6.7%). Post-operative complications occurred in 6/165 horses (3.6%), including alveolar sequestra (n = 4), mild delay of alveolar healing at 2 months (n = 1), and development of a persistent draining tract secondary to a retained root tip (n = 1). Specialised instrumentation and additional training in the technique are recommended to perform partial crown removal in horses. Horses with cheek teeth extraction by partial crown removal have an excellent prognosis for a positive outcome. The term partial coronectomy

  18. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling.

    Science.gov (United States)

    Syrek, Andreas; Reich, Gunnar; Ranftl, Dieter; Klein, Christoph; Cerny, Barbara; Brodesser, Jutta

    2010-07-01

    The aim of the present study was to compare the fit of all-ceramic crowns fabricated from intraoral digital impressions with the fit of all-ceramic crowns fabricated from silicone impressions. Twenty patients agreed to take part in the study to receive two Lava crowns each for the same preparation. One crown was fabricated from intraoral scans using the Lava Chairside Oral Scanner (Lava C.O.S.), and the other crown from a two-step silicone impression. Prior to cementation the fit of both crowns was clinically evaluated by two calibrated and blinded examiners; the marginal fit was also scored from replicas. Data from the replica scores were analysed by Anderson-Darling test, Levene's test and Mann-Whitney test. All tests were performed with alpha-level of 0.05. Median marginal gap in the conventional impression group was 71microm (Q1:45microm; Q3:98microm), and in the digital impression group 49microm (Q1:32microm; Q3:65microm). Mann-Whitney test revealed a significant difference between the groups (pdigitally fabricated crowns. 1. Crowns from intraoral scans revealed significantly better marginal fit than crowns from silicone impressions. 2. Marginal discrepancies in both groups were within the limits of clinical acceptability. 3. Crowns from intraoral scans tended to show better interproximal contact area quality. 4. Crowns from both groups performed equally well with regard to occlusion. Copyright 2010 Elsevier Ltd. All rights reserved.

  19. Chemical modification of poly(vinyl alcohol): evaluation of hydrophilic/lipophilic balance

    International Nuclear Information System (INIS)

    Aranha, Isabele B.; Lucas, Elizabete F.

    2001-01-01

    Poly(vinyl alcohol) terpolymers have been obtained by reaction of partially hydrolized poly(vinyl alcohol) with different acid chlorides. The objective is the preparation of polymers with slight differences in their hydrophilic/lipophilic balance and in the interfacial activities of their solutions. The chemical modifications were characterized by means of 1 H NMR and the polymer properties were evaluated in terms of changes in solubility and surface tension. By chemical modification, polymers with low percentage of hydrophobic group were obtained. The water-soluble polymers obtained did not have the surface tension of their solutions altered. The solubility of the modified polymers decreased markedly, even with low contents of hydrophobic groups. (author)

  20. Comparative analysis of intraoral radiographs with variation of tube angulation to detect insufficient crown margins.

    Science.gov (United States)

    Sailer, Benjamin F; Geibel, Margrit-Ann

    2013-01-01

    Variations in angulation of the x-ray tube affect the appearance of insufficient approximal crown margins on intraoral radiographs. This study examines the impact of such angular variation on the assessment of digital radiographs using three different X-ray tubes--Heliodent DS (Sirona), Gendex Expert DC (KaVo Dental) and Focus (KaVo Dental)--as well as the Gendex Visualix eHD CCD sensor (KaVo Dental). The test specimens, crowned teeth 46 from two mandibles provided by the Institute of Anatomy and Cell Biology, were examined with each tube. The results indicate great differences in the angles indicative of insufficient crown margins on X-ray images. Because of beam divergence and the crown marginal gap, the length and width of which frequently varies, it is difficult to infer any optimum angle from the data. This leads to the conclusion that at present, it is not possible to establish ideal angles for visualization of insufficient approximal crown margins.

  1. Digital evaluation of absolute marginal discrepancy: A comparison of ceramic crowns fabricated with conventional and digital techniques.

    Science.gov (United States)

    Liang, Shanshan; Yuan, Fusong; Luo, Xu; Yu, Zhuoren; Tang, Zhihui

    2018-04-05

    Marginal discrepancy is key to evaluating the accuracy of fixed dental prostheses. An improved method of evaluating marginal discrepancy is needed. The purpose of this in vitro study was to evaluate the absolute marginal discrepancy of ceramic crowns fabricated using conventional and digital methods with a digital method for the quantitative evaluation of absolute marginal discrepancy. The novel method was based on 3-dimensional scanning, iterative closest point registration techniques, and reverse engineering theory. Six standard tooth preparations for the right maxillary central incisor, right maxillary second premolar, right maxillary second molar, left mandibular lateral incisor, left mandibular first premolar, and left mandibular first molar were selected. Ten conventional ceramic crowns and 10 CEREC crowns were fabricated for each tooth preparation. A dental cast scanner was used to obtain 3-dimensional data of the preparations and ceramic crowns, and the data were compared with the "virtual seating" iterative closest point technique. Reverse engineering software used edge sharpening and other functional modules to extract the margins of the preparations and crowns. Finally, quantitative evaluation of the absolute marginal discrepancy of the ceramic crowns was obtained from the 2-dimensional cross-sectional straight-line distance between points on the margin of the ceramic crowns and the standard preparations based on the circumferential function module along the long axis. The absolute marginal discrepancy of the ceramic crowns fabricated using conventional methods was 115 ±15.2 μm, and 110 ±14.3 μm for those fabricated using the digital technique was. ANOVA showed no statistical difference between the 2 methods or among ceramic crowns for different teeth (P>.05). The digital quantitative evaluation method for the absolute marginal discrepancy of ceramic crowns was established. The evaluations determined that the absolute marginal discrepancies were

  2. Optimisation of cosolvent concentration for topical drug delivery III--influence of lipophilic vehicles on ibuprofen permeation.

    Science.gov (United States)

    Watkinson, R M; Guy, R H; Oliveira, G; Hadgraft, J; Lane, M E

    2011-01-01

    Previously, we have reported the effects of water, ethanol, propylene glycol and various binary and ternary mixtures of these solvents on the permeation of ibuprofen in model membranes and in skin. The present study investigates the influence of lipophilic vehicles on the transport of ibuprofen in silicone membrane and in human skin. The permeation of ibuprofen was measured from mineral oil (MO), Miglyol® 812 (MG) and binary mixtures of MO and MG. The solubility of ibuprofen was 5-fold higher in MG than in MO, however, the permeation of ibuprofen from the pure vehicles and combinations of both was comparable in silicone membrane. Additionally, there were no significant differences in skin permeation for MO and MG vehicles. When the permeation of various hydrophilic and lipophilic vehicles is considered, a trend between flux values for the model membrane and skin is evident (r(2) = 0.71). The findings suggest that silicone membrane may provide information on qualitative trends in skin permeation for vehicles of diverse solubility and partition characteristics. Copyright © 2010 S. Karger AG, Basel.

  3. Nanostructuring Biomaterials with Specific Activities towards Digestive Enzymes for Controlled Gastrointestinal Absorption of Lipophilic Bioactive Molecules.

    Science.gov (United States)

    Joyce, Paul; Whitby, Catherine P; Prestidge, Clive A

    2016-11-01

    This review describes the development of novel lipid-based biomaterials that modulate fat digestion for the enhanced uptake of encapsulated lipophilic bioactive compounds (e.g. drugs and vitamins). Specific focus is directed towards analysing how key material characteristics affect the biological function of digestive lipases and manipulate lipolytic digestion. The mechanism of lipase action is a complex, interfacial process, whereby hydrolysis can be controlled by the ability for lipase to access and adsorb to the lipid-in-water interface. However, significant conjecture exists within the literature regarding parameters that influence the activities of digestive lipases. Important findings from recent investigations that strategically examined the interplay between the interfacial composition of the lipid microenvironment and lipolysis kinetics in simulated biophysical environments are presented. The correlation between lipolysis and the rate of solubilisation and absorption of lipophilic compounds in the gastrointestinal tract (GIT) is detailed. Greater insights into the mechanism of lipase action have provided a new approach for designing colloidal carriers that orally deliver poorly soluble compounds, directly impacting the pharmaceutical and food industries. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Management of crown-of-thorns sea star (

    NARCIS (Netherlands)

    Bos, A.R.; Gumanao, G.S.; Mueller, B.; Saceda-Cardoza, M.M.E.

    2013-01-01

    Removals of crown-of-thorns sea stars (Acanthaster planci L) are crucial initiatives in limiting the damage to coral reefs during outbreaks, but have often been unable to control the populations. We hypothesized that reef topography and exact timing of removals (before reproduction) determine their

  5. Needle-Age Related Variability in Nitrogen, Mobile Carbohydrates, and δ13C within Pinus koraiensis Tree Crowns

    Science.gov (United States)

    Yan, Cai-Feng; Han, Shi-Jie; Zhou, Yu-Mei; Wang, Cun-Guo; Dai, Guan-Hua; Xiao, Wen-Fa; Li, Mai-He

    2012-01-01

    For both ecologists and physiologists, foliar physioecology as a function of spatially and temporally variable environmental factors such as sunlight exposure within a tree crown is important for understanding whole tree physiology and for predicting ecosystem carbon balance and productivity. Hence, we studied concentrations of nitrogen (N), non-structural carbohydrates (NSC = soluble sugars + starch), and δ13C in different-aged needles within Pinus koraiensis tree crowns, to understand the needle age- and crown position-related physiology, in order to test the hypothesis that concentrations of N, NSC, and δ13C are needle-age and crown position dependent (more light, more photosynthesis affecting N, NSC, and δ13C), and to develop an accurate sampling strategy. The present study indicated that the 1-yr-old needles had significantly higher concentration levels of mobile carbohydrates (both on a mass and an area basis) and Narea (on an area basis), as well as NSC-N ratios, but significantly lower levels of Nmass (on a mass basis) concentration and specific leaf area (SLA), compared to the current-year needles. Azimuthal (south-facing vs. north-facing crown side) effects were found to be significant on starch [both on a mass (STmass) and an area basis (STarea)], δ13C values, and Narea, with higher levels in needles on the S-facing crown side than the N-facing crown side. Needle Nmass concentrations significantly decreased but needle STmass, STarea, and δ13C values significantly increased with increasing vertical crown levels. Our results suggest that the sun-exposed crown position related to photosynthetic activity and water availability affects starch accumulation and carbon isotope discrimination. Needle age associated with physiological activity plays an important role in determining carbon and nitrogen physiology. The present study indicates that across-scale sampling needs to carefully select tissue samples with equal age from a comparable crown position

  6. Lipophilic phytosterol derivatives: synthesis, thermal property and nanoemulsion behavior

    DEFF Research Database (Denmark)

    Panpipat, Worawan; Xu, Xuebing; Guo, Zheng

    Phytosterols and their esters have been reported as a cholesterol lowering agent in human. However, natural phytosterols have a low solubility in both water and fat resulting in a poor absorption in intestine. To improve the intestinal absorption and bioavailability of phytosterols, conversion...... of phytosterols into enzyme-liable lipophilic derivatives, such as fatty acid esters was one of the possible strategies. Differences in molecular structures of modified phytosterols may result in the differences in their thermal and micelling behaviors. Therefore, the objectives of this study were to improve...... the productive yield of a series of -sitosteryl fatty acid esters (C2-C18) and to investigate the thermal property and nano-emulsion behaviors of those compounds. This work reported a novel approach to synthesize phytosterol (-sitosterol as a model) fatty acid ester by employing Candida antarctica lipase...

  7. A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns.

    Science.gov (United States)

    Sulaiman, F; Chai, J; Jameson, L M; Wozniak, W T

    1997-01-01

    The in vitro marginal fit of three all-ceramic crown systems (In-Ceram, Procera, and IPS Empress) was compared. All crown systems were significantly different from each other at P = 0.05. In-Ceram exhibited the greatest marginal discrepancy (161 microns), followed by Procera (83 microns), and IPS Empress (63 microns). There were no significant differences among the various stages of the crown fabrication: core fabrication, porcelain veneering, and glazing. The facial and lingual margins exhibited significantly larger marginal discrepancies than the mesial and distal margins.

  8. Fast gradient HPLC method to determine compounds binding to human serum albumin. Relationships with octanol/water and immobilized artificial membrane lipophilicity.

    Science.gov (United States)

    Valko, Klara; Nunhuck, Shenaz; Bevan, Chris; Abraham, Michael H; Reynolds, Derek P

    2003-11-01

    A fast gradient HPLC method (cycle time 15 min) has been developed to determine Human Serum Albumin (HSA) binding of discovery compounds using chemically bonded protein stationary phases. The HSA binding values were derived from the gradient retention times that were converted to the logarithm of the equilibrium constants (logK HSA) using data from a calibration set of molecules. The method has been validated using literature plasma protein binding data of 68 known drug molecules. The method is fully automated, and has been used for lead optimization in more than 20 company projects. The HSA binding data obtained for more than 4000 compounds were suitable to set up global and project specific quantitative structure binding relationships that helped compound design in early drug discovery. The obtained HSA binding of known drug molecules were compared to the Immobilized Artificial Membrane binding data (CHI IAM) obtained by our previously described HPLC-based method. The solvation equation approach has been used to characterize the normal binding ability of HSA, and this relationship shows that compound lipophilicity is a significant factor. It was found that the selectivity of the "baseline" lipophilicity governing HSA binding, membrane interaction, and octanol/water partition are very similar. However, the effect of the presence of positive or negative charges have very different effects. It was found that negatively charged compounds bind more strongly to HSA than it would be expected from the lipophilicity of the ionized species at pH 7.4. Several compounds showed stronger HSA binding than can be expected from their lipophilicity alone, and comparison between predicted and experimental binding affinity allows the identification of compounds that have good complementarities with any of the known binding sites. Copyright 2003 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 92:2236-2248, 2003

  9. The principles for creation of fire-prevention forest belts with barriers of deciduous species for protection from crown fires

    Directory of Open Access Journals (Sweden)

    S. N. Sannikov

    2017-10-01

    Full Text Available The article discuss one of the priority security problems in Russia, which is elaboration of the strategic system of the forest and society safeguards from catastrophic forest crown fires in connection with rapid climate warming. It is postulated, that a most effective and reliable barrier for the dispersal of the intensive crown fire in a coniferous forest massive can be a sufficiently wide strip of deciduous tree species – «deciduous forest barrier», which has phytomass capable of absorbing crown fire energy and transforming them to surface fire, which may be extinguished by technical means. The actuality of the natural study of the transition parameters from the crown fire to surface fire has been noted, depending on climate, fire intensity and the deciduous barrier structure. The results of the quantitative natural investigation of the consequences of catastrophic crown fires of 2004 in the island pine forests of forest-steppe zone in Kurgan Oblast, which passed through the belt of 50–70 year-old birch stands of middle density, has been cited and formalized mathematically. It has been shown, that 150 m width of deciduous forest barrier is necessary as a minimum for the reliable transition of the high intensive front crown fire to surface fire in the forest-steppe conditions of the Western Siberia, but this width reduces with a decreasing heating effect. It has been proposed to create the complex fire-prevention forest belts of different construction for the protection of forests, industrial objects and settlements. Besides a basic deciduous barrier, their structure should include technologically necessary buffer zones and zones for the localization and extinguishing surface fire, which stop a crown fire. It has been recommended to use natural regeneration of deciduous tree species, as a most effective and non-deficient method for the creation of deciduous forest barriers in the predominant forest types, except the lichen pine forests

  10. A benchmark study for the crown-type splashing dynamics of one- and two-component droplet wall-film interactions

    Science.gov (United States)

    Geppert, A.; Terzis, A.; Lamanna, G.; Marengo, M.; Weigand, B.

    2017-12-01

    The present paper investigates experimentally the impact dynamics of crown-type splashing for miscible two- and one-component droplet wall-film interactions over a range of Weber numbers and dimensionless film thicknesses. The splashing outcome is parametrised in terms of a set of quantifiable parameters, such as crown height, top and base diameter, wall inclination, number of fingers, and secondary droplet properties. The results show that the outcome of a splashing event is not affected by the choice of similar or dissimilar fluids, provided the dimensionless film thickness is larger than 0.1. Below this threshold, distinctive features of two-component interactions appear, such as hole formation and crown bottom breakdown. The observation of different crown shapes (e.g. V-shaped, cylindrical, and truncated-cone) confirms that vorticity production induces changes in the crown wall inclination, thus affecting the evolution of the crown height and top diameter. The evolution of the crown base diameter, instead, is mainly dependent on the relative importance of liquid inertia and viscous losses in the wall-film. The maximum number of liquid fingers decreases with increasing wall, film thickness, due to the enhanced attenuation of the effect of surface properties on the fingering process. The formation of secondary droplets is also affected by changes in the crown wall inclination. In particular, for truncated-cone shapes the occurrence of crown rim contraction induces a large scatter in the secondary droplet properties. Consequently, empirical models for the maximum number and mean diameter of the secondary droplets are derived for V-shaped crowns, as observed for the hexadecane-Hyspin interactions.

  11. The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional

    Directory of Open Access Journals (Sweden)

    Seyyed Mohammad Abrisham

    2012-09-01

    Full Text Available Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI, 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughened with sandblast (50-µm aluminum oxide and in the second group, 10 abutments were roughened with diamond bur. The third group had no surface treatment. Then, thirty implant fixture analogs (ITI were placed in the center of acrylic cylinders. After that a solid abutment was tightened on the each fixture analog with 35 N/cm force. Thirty base metal crowns were made on the 4 mm ITI abutment analogs using plastic coping. The prepared copings were cemented on the abutments by TempBond temporary cement and finally, crowns were pulled from the abutment in a universal test machine at a cross speed of 0.5cm/min. Results: The mean tensile strength in sandblasted, bur treated, and control group were 64.38±8, 91.37±7.19, and 58.61±1.93, respectively. Bur treated group showed higher tensile strength in comparison with two other groups. Conclusion: Surface modification of implant abutment by diamond bur may be an effective method to increase retention of crown when TempBond is used.

  12. Evaluation of Mechanical Properties and Marginal Fit of Crowns Fabricated Using Commercially Pure Titanium and FUS-Invest

    Directory of Open Access Journals (Sweden)

    Jinshuang Wu

    2017-01-01

    Full Text Available This study investigated the mechanical properties and single crown accuracy of the tailor-made Fourth University Stomatology investment (FUS-invest for casting titanium. Background. Current investment for casting titanium is not optimal for obtaining high-quality castings, and the commercially available titanium investment is costly. Methods. Titanium specimens were cast using the tailor-made FUS-invest. The mechanical properties were tested using a universal testing machine. Fractured castings were characterized by energy-dispersive spectroscopy. 19 titanium crowns were produced using FUS-invest and another 19 by Symbion. The accuracy of crowns was evaluated. Results. The mechanical properties of the titanium cast by FUS-invest were elastic modulus 125.6 ± 8.8 GPa, yield strength 567.5 ± 11.1 MPa, tensile strength 671.2 ± 15.6 MPa, and elongation 4.6 ± 0.2%. For marginal fit, no significant difference (P>0.05 was found at four marker points of each group. For internal fit, no significant difference (P>0.05 was found between two groups, whereas significant difference (P<0.01 was found at different mark point of each group. Conclusions. The mechanical properties of titanium casted using FUS-invest fulfilled the ISO 9693 criteria. The marginal and internal fit of the titanium crowns using either the FUS-invest or Symbion were similar.

  13. Aesthetic treatment on anterior teeth crown fracture caused by dental trauma

    Directory of Open Access Journals (Sweden)

    Nanik Zubaidah

    2012-12-01

    Full Text Available Background: Complicated crown fracture is a tooth fracture that involve enamel, dentine and pulp. The incidence of complicated crown fracture ranges from 2% to 13% of all dental injuries and the most commonly involved teeth are the maxillary central incisors. Various treatment modalities are available depending on the clinical, physiological and radiographic examination of the involved teeth. Purpose: The aim of this case report is to present the management of crown fractures with pulpal exposure caused by traumatic injury, through endorestoration approach to reconstruct the shape and function of the teeth. Case: A 17 years old male with complicated crown fractures of anterior teeth #11 #21 and #22. The patient wish for aesthetic dental treatment in both of its form and function. Case management: Crown fractures of anterior teeth with exposed pulp caused by traumatic injury were reconstructed by endorestoration approach. The endodontic treatment with post and core insertion in the root canal which will increase its retention and porcelain fused to metal crown which will aesthetically recover its original form and function. After restoration the patient feel very glad and confident with the result. Conclusion: Endorestoration treatment on anterior teeth with complicated crown fractures and exposed pulp is able to recover the normal form, function and dental aesthetic in accordance with stomatognatic system and self confidence.Latar belakang: Fraktur mahkota kompleks (complicated adalah fraktur pada mahkota gigi yang melibatkan enamel, dentin dan pulpa. Kejadian dari fraktur mahkota kompleks bervariasi antara 2-13% dari semua trauma gigi dan sebagian besar gigi yang terkena adalah gigi insisif pertama rahang atas. Berbagai macam cara perawatan yang dilakukan tergantung pada hasil pemeriksaan klinis, psikologis dan radiografis dari gigi yang terkena. Tujuan: Laporan kasus ini menjelaskan penatalaksanaan fraktur mahkota gigi dengan pulpa terbuka

  14. FULLY AUTOMATED GIS-BASED INDIVIDUAL TREE CROWN DELINEATION BASED ON CURVATURE VALUES FROM A LIDAR DERIVED CANOPY HEIGHT MODEL IN A CONIFEROUS PLANTATION

    Directory of Open Access Journals (Sweden)

    R. J. L. Argamosa

    2016-06-01

    Full Text Available The generation of high resolution canopy height model (CHM from LiDAR makes it possible to delineate individual tree crown by means of a fully-automated method using the CHM’s curvature through its slope. The local maxima are obtained by taking the maximum raster value in a 3 m x 3 m cell. These values are assumed as tree tops and therefore considered as individual trees. Based on the assumptions, thiessen polygons were generated to serve as buffers for the canopy extent. The negative profile curvature is then measured from the slope of the CHM. The results show that the aggregated points from a negative profile curvature raster provide the most realistic crown shape. The absence of field data regarding tree crown dimensions require accurate visual assessment after the appended delineated tree crown polygon was superimposed to the hill shaded CHM.

  15. Tree-crown-resolving large-eddy simulation for evaluating greenery effects on urban heat environments

    Science.gov (United States)

    Matsuda, K.; Onishi, R.; Takahashi, K.

    2017-12-01

    Urban high temperatures due to the combined influence of global warming and urban heat islands increase the risk of heat stroke. Greenery is one of possible countermeasures for mitigating the heat environments since the transpiration and shading effect of trees can reduce the air temperature and the radiative heat flux. In order to formulate effective measures, it is important to estimate the influence of the greenery on the heat stroke risk. In this study, we have developed a tree-crown-resolving large-eddy simulation (LES) model that is coupled with three-dimensional radiative transfer (3DRT) model. The Multi-Scale Simulator for the Geoenvironment (MSSG) is used for performing building- and tree-crown-resolving LES. The 3DRT model is implemented in the MSSG so that the 3DRT is calculated repeatedly during the time integration of the LES. We have confirmed that the computational time for the 3DRT model is negligibly small compared with that for the LES and the accuracy of the 3DRT model is sufficiently high to evaluate the radiative heat flux at the pedestrian level. The present model is applied to the analysis of the heat environment in an actual urban area around the Tokyo Bay area, covering 8 km × 8 km with 5-m grid mesh, in order to confirm its feasibility. The results show that the wet-bulb globe temperature (WBGT), which is an indicator of the heat stroke risk, is predicted in a sufficiently high accuracy to evaluate the influence of tree crowns on the heat environment. In addition, by comparing with a case without the greenery in the Tokyo Bay area, we have confirmed that the greenery increases the low WBGT areas in major pedestrian spaces by a factor of 3.4. This indicates that the present model can predict the greenery effect on the urban heat environment quantitatively.

  16. 18F-fluorination by crown ether-metal fluoride

    International Nuclear Information System (INIS)

    Irie, T.; Fukushi, K.; Ido, T.; Kasida, Y.; Nozaki, T.

    1982-01-01

    18 F-Fluorination by ''naked'' 18 F - anion produced by complexing anhydrous K 18 F, which was prepared from aqueous 18 F, with 18 -Crown-6 was described for preparing 18 F-21-fluoroprogesterone. In order to find out optimum conditions in this labelling method, various factors were investigated such as the solubility of KF in organic solvents containing 18 -Crown-6 and its reactivity for the nucleophilic displacement of 21-mesylate of progesterone. Chloroform was a good solvent in solubilization of KF and its reactivity. Problems in this labelling procedure were also examined, such as a supporter for transferring the labelled anhydrous K 18 F and reaction vessels. Use of a Teflon reaction vessel resulted in a good radiochemical yield based on the starting activity of $ 18 water. (author)

  17. Influence of ionizing radiation and 12-crown-4 on coagulation system components of rat blood

    International Nuclear Information System (INIS)

    Kratenko, R.Yi.

    2006-01-01

    The influence of 12-crown-4 and ionizing radiation on some components of blood coagulation system: Ca 2+ contents and prostaglandin concentrations in the blood serum, and erythrocyte contents in the blood plasma are studied. The influence of 12-crown-4 and ionizing radiation increases the coagulational properties of erythrocytes. The synergism of ionizing irradiation and 12-crown-4 influence blood coagulation process points out at the occurrence of radiomimetic properties of the latter

  18. Effect of electrostatic interaction on thermochemical behavior of 12-crown-4 ether in various polar solvents

    International Nuclear Information System (INIS)

    Barannikov, Vladimir P.; Guseynov, Sabir S.; Vyugin, Anatoliy I.

    2010-01-01

    The enthalpies of solution of 12-crown-4 ether have been measured in chloroform, ethyl acetate, acetone, pyridine, acetonitrile and methanol at 298.15 K. The values of enthalpy of solvation and solute-solvent interaction were determined from the obtained results and similar literature data for 12-crown-4 in solvents of various polarities. It was shown that the certain correlation is observed between the enthalpy of solute-solvent interaction and the squared dipole moment of the solvent molecules for solutions in tetrachlormethane, ethyl acetate, pyridine, acetonitrile, DMF, DMSO and propylene carbonate. This means that the electrostatic interaction of 12-crown-4 with polar solvent molecules contributes significantly to the exothermic effect of solvation. The understated negative value was found for the enthalpy of interaction of 12-crown-4 with acetone that can be connected with domination of low polar conformer of the crown ether in acetone medium. The most negative values of enthalpy of solvation are observed for solutions in chloroform and water because of hydrogen bonding between O-atoms of crown ether and molecules of the indicated solvents. This effect is not observed for methanol. The negative coefficient of pairwise solute-solute interaction in methanol indicates that the effects of solvophobic solute-solute interaction and H-bonding of the ether molecule with chain associates of methanol are not evinced in the thermochemical behavior of 12-crown-4.

  19. Partial molar volumes of organic solutes in water. XXVI. 15-Crown-5 and 18-crown-6 ethers at temperatures (298 to 573) K and pressures up to 30 MPa

    International Nuclear Information System (INIS)

    Cibulka, Ivan

    2015-01-01

    Highlights: • Density data were obtained in the range T from (298 to 573) K and p up to 30 MPa. • Standard molar volumes of two crown ethers in water are presented. • Group contribution method was designed to estimate standard molar volumes of cyclic ethers. - Abstract: Densities of dilute aqueous solutions of two cyclic ethers, viz. 15-crown-5 and 18-crown-6, measured over the temperature range from (298 to 573) K and at pressures up to 30 MPa using an automated flow vibrating-tube densimeter are reported. Standard molar volumes were evaluated from the measured data. Present data were combined with those obtained previously for several cyclic ethers and predictions of standard molar volumes based on group contribution approach were tested and analysed

  20. Assessment of crown fire initiation and spread models in Mediterranean conifer forests by using data from field and laboratory experiments

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez y Silva, F.; Guijarro, M.; Madrigal, J.; Jiménez, E.; Molina, J.R.; Hernando, C.; Vélez, R.; Vega, J.A.

    2017-11-01

    Aims of study: To conduct the first full-scale crown fire experiment carried out in a Mediterranean conifer stand in Spain; to use different data sources to assess crown fire initiation and spread models, and to evaluate the role of convection in crown fire initiation. Area of study: The Sierra Morena mountains (Coordinates ETRS89 30N: X: 284793-285038; Y: 4218650-4218766), southern Spain, and the outdoor facilities of the Lourizán Forest Research Centre, northwestern Spain. Material and methods: The full-scale crown fire experiment was conducted in a young Pinus pinea stand. Field data were compared with data predicted using the most used crown fire spread models. A small-scale experiment was developed with Pinus pinaster trees to evaluate the role of convection in crown fire initiation. Mass loss calorimeter tests were conducted with P. pinea needles to estimate residence time of the flame, which was used to validate the crown fire spread model. Main results: The commonly used crown fire models underestimated the crown fire spread rate observed in the full-scale experiment, but the proposed new integrated approach yielded better fits. Without wind-forced convection, tree crowns did not ignite until flames from an intense surface fire contacted tree foliage. Bench-scale tests based on radiation heat flux therefore offer a limited insight to full-scale phenomena. Research highlights: Existing crown fire behaviour models may underestimate the rate of spread of crown fires in many Mediterranean ecosystems. New bench-scale methods based on flame buoyancy and more crown field experiments allowing detailed measurements of fire behaviour are needed.

  1. Assessment of crown fire initiation and spread models in Mediterranean conifer forests by using data from field and laboratory experiments

    International Nuclear Information System (INIS)

    Rodríguez y Silva, F.; Guijarro, M.; Madrigal, J.; Jiménez, E.; Molina, J.R.; Hernando, C.; Vélez, R.; Vega, J.A.

    2017-01-01

    Aims of study: To conduct the first full-scale crown fire experiment carried out in a Mediterranean conifer stand in Spain; to use different data sources to assess crown fire initiation and spread models, and to evaluate the role of convection in crown fire initiation. Area of study: The Sierra Morena mountains (Coordinates ETRS89 30N: X: 284793-285038; Y: 4218650-4218766), southern Spain, and the outdoor facilities of the Lourizán Forest Research Centre, northwestern Spain. Material and methods: The full-scale crown fire experiment was conducted in a young Pinus pinea stand. Field data were compared with data predicted using the most used crown fire spread models. A small-scale experiment was developed with Pinus pinaster trees to evaluate the role of convection in crown fire initiation. Mass loss calorimeter tests were conducted with P. pinea needles to estimate residence time of the flame, which was used to validate the crown fire spread model. Main results: The commonly used crown fire models underestimated the crown fire spread rate observed in the full-scale experiment, but the proposed new integrated approach yielded better fits. Without wind-forced convection, tree crowns did not ignite until flames from an intense surface fire contacted tree foliage. Bench-scale tests based on radiation heat flux therefore offer a limited insight to full-scale phenomena. Research highlights: Existing crown fire behaviour models may underestimate the rate of spread of crown fires in many Mediterranean ecosystems. New bench-scale methods based on flame buoyancy and more crown field experiments allowing detailed measurements of fire behaviour are needed.

  2. Transmission electron microscopical study of teenage crown dentin on the nanometer scale

    Energy Technology Data Exchange (ETDEWEB)

    Panfilov, Peter, E-mail: peter.panfilov@urfu.ru [Ural Federal University, Ekaterinburg (Russian Federation); Kabanova, Anna [Ural Federal University, Ekaterinburg (Russian Federation); Guo, Jinming; Zhang, Zaoli [Erich Schmid Institute for Materials Science, Austrian Academy of Sciences, Leoben (Austria)

    2017-02-01

    Statement of significance: This is the first transmission electron microscopic study of teenage crown dentin on the nanometer scale. Samples for TEM were prepared by mechanical thinning and chemical polishing that allowed obtaining the electron transparent foils. It was firstly shown that human dentin possesses the layered morphology: the layers are oriented normally to the main axis of a tooth and have the thickness of ~ 50 nm. HA inorganic phase of teenage crown dentin is in the amorphous state. The cellular structure, which was formed from collagen fibers (diameter is ~ 5 nm), are observed near DEJ region in teenage dentin, whereas bioorganic phase of teenage crown dentin near the pulp camera does not contain the collagen fibers. Cracks in dentin thin foils have sharp tips, but big angles of opening (~ 30{sup °}) with plastic zone ahead crack tip. It means that young crown human dentin exhibits ductile or viscous-elastic fracture behavior on the nanometer scale. - Highlights: • Dentin has layered morphology. • Mineral component of dentin is in amorphous state. • Collagen fibers form cellular structure in dentin. • Cracks in dentin behave by elastic-plastic manner.

  3. Transmission electron microscopical study of teenage crown dentin on the nanometer scale

    International Nuclear Information System (INIS)

    Panfilov, Peter; Kabanova, Anna; Guo, Jinming; Zhang, Zaoli

    2017-01-01

    Statement of significance: This is the first transmission electron microscopic study of teenage crown dentin on the nanometer scale. Samples for TEM were prepared by mechanical thinning and chemical polishing that allowed obtaining the electron transparent foils. It was firstly shown that human dentin possesses the layered morphology: the layers are oriented normally to the main axis of a tooth and have the thickness of ~ 50 nm. HA inorganic phase of teenage crown dentin is in the amorphous state. The cellular structure, which was formed from collagen fibers (diameter is ~ 5 nm), are observed near DEJ region in teenage dentin, whereas bioorganic phase of teenage crown dentin near the pulp camera does not contain the collagen fibers. Cracks in dentin thin foils have sharp tips, but big angles of opening (~ 30 ° ) with plastic zone ahead crack tip. It means that young crown human dentin exhibits ductile or viscous-elastic fracture behavior on the nanometer scale. - Highlights: • Dentin has layered morphology. • Mineral component of dentin is in amorphous state. • Collagen fibers form cellular structure in dentin. • Cracks in dentin behave by elastic-plastic manner.

  4. Effects of Different Lipophilized Ferulate Esters in Fish Oil-Enriched Milk: Partitioning, Interaction, Protein, and Lipid Oxidation

    DEFF Research Database (Denmark)

    Qiu, Xujian; Jacobsen, Charlotte; Villeneuve, Pierre

    2017-01-01

    Antioxidant effects of ferulic acid and lipophilized ferulate esters were investigated in fish oil-enriched milk. Methyl ferulate (C1) and ethyl ferulate (C2) more efficiently prevented lipid oxidation than dodecyl ferulate (C12) did, followed by ferulic acid (C0). The combination of C1 or C2 wit...

  5. Design and synthesis of the next generation of crown ethers for waste separations: An inter-laboratory comprehensive proposal. 1998 annual progress report

    International Nuclear Information System (INIS)

    Alexandratos, S.D.; Chiarizia, R.; Dietz, M.L.; Hay, B.P.; Moyer, B.A.; Sachleben, R.A.

    1998-01-01

    'The purpose of this task is to undertake the design, synthesis, and characterization of the next generation of crown ethers for metal-ion separations applicable to USDOE''s environmental needs. Target problems include: Li + ions leaching from burial sites at the Oak Ridge Y-12 Plant; fission products 90 Sr and 137 Cs contaminating high-level tank wastes at Hanford, INEEL, and Savannah River; and radium in wastes at the Niagara Falls Storage Site. Unfortunately, the technologies needed to address these problems either do not exist or exhibit substantial deficiencies. Separation techniques such as solvent extraction and ion exchange promise to play a strong role, especially as enhanced with highly selective crown ethers and calixarenes. This project is midway through year 2 of a 3-year effort. Below is given a summary of progress in the approximate period September, 1997, to May, 1998, for each of the four co-investigators at Pacific Northwest National Laboratory (PNNL), Argonne National Laboratory (ANL), Oak Ridge National Laboratory (ORNL), and the University of Tennessee (UTK). The overall approach entails utilization of theory and molecular modeling (PNNL), organic synthesis of novel crown compounds (ORNL), solvent extraction studies (ORNL and ANL), and studies of polymer-immobilized crown ethers (UTK).'

  6. Ready to crown

    LENUS (Irish Health Repository)

    McReynolds, David

    2017-04-01

    When multiple teeth or localised segments of the mouth require crowns, the restorative interventions involved can be psychologically and physically demanding for the operator, patient and dental technician alike.1,2 It is important that all parties involved in restorations of this nature hold a shared understanding of the expected outcome of treatment, with a realistic, common end goal in mind right from the very beginning. Such clarity of thought and communication is key to avoiding biological, mechanical and aesthetic failures in the planning and execution of advanced restorative treatments. Biomechanically stable and aesthetically pleasing provisional restorations are an essential aspect of treatment, which allow teeth to be prepared and provisionalised over multiple appointments within the comfort zone of the operator and patient.3

  7. Radiosensitivity and recovery of tree crowns in a gamma-irradiated northern forest community

    International Nuclear Information System (INIS)

    Buech, R.R.

    1977-01-01

    Crown mortality was observed on 13 tree species in a gamma-irradiated forest community located near Rhinelander, Wis. Observations at the end of the first (1973) and second (1974) postirradiation growing seasons are presented for each species. Crown mortality was most severe during 1973 for Acer rubrum, A. saccharum, Ostrya virginiana, Populus tremuloides, Prunus serotina, Quercus rubra, and Ulmus americana. For some species, however, crown mortality was most severe during 1974. These were Betula alleghaniensis, B. papyrifera, Tilia americana, and possibly Fraxinus americana and F. nigra. These differences in year of primary response are explained on the basis of bud differentiation and mortality. The most resistant species were A. saccharum, O. virginiana, and Populus tremuloides, and the most sensitive were T. americana and U. americana. Others were intermediate in sensitivity. Taken collectively, exposures less than 2 or 3 kr did not seriously affect crowns of most species, whereas exposures exceeding about 40 kr were lethal to the crowns of all tree species. The observed zonation of tree mortality closely approximated predictions published by others except for underestimating the resistance of A. saccharum and overestimating the resistance of T. americana, F. americana, and Prunus serotina. Not surprisingly, the tree stratum of the northern forest community was found to be more radiosensitive than lichen, grassland, or herbaceous communities in other irradiation studies

  8. On-chip microreactor system for the production of nano-emulsion loaded liposomes: towards targeted delivery of lipophilic drugs

    NARCIS (Netherlands)

    Langelaan, M.L.P.; Emmelkamp, J.; Segers, M.J.A.; Lenting, H.B.M.

    2011-01-01

    An on-chip microreactor system for the production of novel nano-biodevices is presented. This nano-biodevice consists of a nano-emulsion loaded with lipophilic drugs, entrapped in liposomes. These nano-biodevices can be equipped with targeting molecules for higher drug efficiency. The microreactor

  9. Influence of a microemulsion vehicle on cutaneous bioequivalence of a lipophilic model drug assessed by microdialysis and pharmacodynamics

    DEFF Research Database (Denmark)

    Kreilgaard, Mads; Kemme, M J; Burggraaf, J

    2001-01-01

    The aim of the study was to investigate the cutaneous bioequivalence of a lipophilic model drug (lidocaine) applied in a novel topical microemulsion vehicle, compared to a conventional oil-in-water (O/W) emulsion, assessed by a pharmacokinetics microdialysis model and a pharmacodynamic method....

  10. Fit of lithium disilicate crowns fabricated from conventional and digital impressions assessed with micro-CT.

    Science.gov (United States)

    Kim, Jae-Hyun; Jeong, Ji-Hye; Lee, Jin-Han; Cho, Hye-Won

    2016-10-01

    Although the number of lithium disilicate crowns fabricated with computer-aided design and computer-aided manufacturing (CAD-CAM) technology has increased, the accuracy of the prostheses produced by using digital pathways remains unknown. The purpose of this in vitro study was to compare marginal and internal discrepancies of lithium disilicate crowns fabricated from digital and conventional impressions. A typodont mandibular first molar was prepared for a lithium disilicate crown, and 20 duplicate dies were fabricated by milling poly(methyl methacrylate) resin blocks from laboratory scans. Four groups of 5 lithium disilicate crowns each were created by using a CS3500 (Carestream Dental) intraoral digital impression; Trios (3shape) intraoral digital impression; Ceramill Map400 (Amann Girrbach) extraoral digital impression; and a heat-press technique as a control group. All of the IPS e.max CAD (Ivoclar Vivadent AG) crowns were produced using a 5-axis milling engine (Ceramill Motion2). The lithium disilicate crowns were cemented with zinc phosphate cement under finger pressure. Marginal and internal discrepancies were measured using micro-computed tomography (SkyScan1172). One-way ANOVAs with the Tukey honest significant differences test were used for statistical analysis of the data (α=.05). The mean marginal discrepancies of CS3500 lithium disilicate crowns were 129.6 μm, 200.9 μm for Ceramill Map400, and 207.8 μm 176.1 μm for the heat-press technique; and the internal discrepancy volumes for CS3500 were 25.3 mm 3 , 40.7 mm 3 for Trios, 29.1 mm 3 for Ceramill Map400, and 29.1 and 31.4 mm 3 for the heat-press technique. The CS3500 group showed a significantly better marginal discrepancy than the other 3 groups and a smaller internal discrepancy volume than the Trios group (Pdigital impressions, whereas no differences were found between IPS e.max CAD crowns produced from an extraoral digital impression and IPS e.max Press crowns produced using a heat

  11. Rhizoctonia crown and root rot disease nursery

    Science.gov (United States)

    The BSDF cooperative CRR Eastern Evaluation Nursery Rhizoctonia crown and root rot Evaluation Nursery in 2016 was a randomized complete-block design with five replications in 15 feet long, one-row plots (20 in row spacing), at the Saginaw Valley Research and Education Center near Frankenmuth, MI. F...

  12. Fracture resistance of aluminium oxide and lithium disilicate-based crowns using different luting cements: an in vitro study.

    Science.gov (United States)

    Al-Wahadni, Ahed M; Hussey, David L; Grey, Nicholas; Hatamleh, Muhanad M

    2009-03-01

    The aim of this study was to investigate the fracture resistance of two types of ceramic crowns cemented with two different cements. Forty premolar crowns were fabricated using lithium-disilicate (IPS Empress-2) and glass-infiltrated aluminium-oxide (In-Ceram) ceramic systems. The crowns were divided into four groups (n=10) with Group 1 (IPS Empress-2) and Group 2 (In-Ceram) cemented with glass ionomer cement. Group 3 (IPS Empress-2) and Group 4 (In-Ceram) were cemented with resin cement. Crowns were tested in a universal testing machine at a compressive-load speed of 10 mm/min. Fracture modes were grouped into five categories. One way analysis of variance (ANOVA) and Bonferroni post-hoc tests were used to detect statistical significances (p0.05) on fracture resistance within each ceramic system tested. In-Ceram crowns cemented with either glass ionomer or resin cements exhibited a statistically significantly higher fracture-resistance than IPS Empress-2 crowns (pEmpress-2 and In-Ceram crowns was not affected by the type of cement used for luting. Both In-Ceram and IPS Empress-2 crowns can be successfully luted with the cements tested with In-Ceram exhibiting higher fracture resistance than IPS Empress-2.

  13. Composite Bonding to Stainless Steel Crowns Using a New Universal Bonding and Single-Bottle Systems

    OpenAIRE

    Mohammad Ali Hattan; Sharat Chandra Pani; Mohammad AlOmari

    2013-01-01

    Aim. The aim of this study is to evaluate the shear bond strength of nanocomposite to stainless steel crowns using a new universal bonding system. Material and Methods. Eighty (80) stainless steel crowns (SSCs) were divided into four groups (20 each). Packable nanocomposite was bonded to the lingual surface of the crowns in the following methods: Group A without adhesive (control group), Group B using a new universal adhesive system (Scotchbond Universal Adhesive, 3M ESPE, Seefeld, Germany), ...

  14. Fatigue resistance of 2 different CAD/CAM glass-ceramic materials used for single-tooth implant crowns.

    Science.gov (United States)

    Çavuşoğlu, Yeliz; Sahin, Erdal; Gürbüz, Riza; Akça, Kivanç

    2011-10-01

    To evaluate the fatigue resistance of 2 different CAD/CAM in-office monoceramic materials with single-tooth implant-supported crowns in functional area. A metal experimental model with a dental implant was designed to receive in-office CAD/CAM-generated monoceramic crowns. Laterally positioned axial dynamic loading of 300 N at 2 Hz was applied to implant-supported crowns machined from 2 different glass materials for 100,000 cycle. Failures in terms of fracture, crack formation, and chipping were macroscopically recorded and microscopically evaluated. Four of 10 aluminasilicate glass-ceramic crowns fractured at early loading cycles, the rest completed loading with a visible crack formation. Crack formation was recorded for 2 of 10 leucite glass-ceramic crowns. Others completed test without visible damage but fractured upon removal. Lack in chemical adhesion between titanium abutment and dental cement likely reduces the fatigue resistance of machinable glass-ceramic materials. However, relatively better fractural strength of leucite glass-ceramics could be taken into consideration. Accordingly, progress on developmental changes in filler composition of glass-ceramics may be promising. Machinable glass-ceramics do not possess sufficient fatigue resistance for single-tooth implant crowns in functional area.

  15. Design algorithm for generatrix profile of cylindrical crowned rollers

    Directory of Open Access Journals (Sweden)

    Creţu Spiridon

    2017-01-01

    Full Text Available The cross-section of roller profile controls the pressure distribution in the contact area and radically affects the roller bearings basic dynamic load rating and rating lives. Today the most used roller profiles are the logarithmic profile and cylindrical-crowned (ZB profile. The logarithmic profile has a continuous evolution with no discontinuities till the intersection with the end fillet while ZB profile has two more discontinuities at the intersections points between the crowning circle and straight line generatrix. Using a semianalytical method, a numerical study has been carried out to find the optimum ZB profile for rollers incorporated in cylindrical rollers bearings. The basic reference rating life (L10_r has been used as optimization criterion.

  16. Crown ether complexes of actinide elements. An X-ray study of the conformational change of the crown ether within the UO/sub 2/(NO/sub 3/)/sub 2/(H/sub 2/O)/sub 2/(18-crown-6) molecule

    Energy Technology Data Exchange (ETDEWEB)

    Bombieri, G; De Paoli, G [Consiglio Nazionale delle Ricerche, Padua (Italy). Lab. di Chimica e Tecnologia dei Radioelementi; Immirzi, A

    1978-01-01

    Uranyl nitrate dihydrate-18-crown-6 crystallizes in the triclinic system with a = 9.072(3), b = 9.144(3), c = 8.323(3) A; ..cap alpha.. = 64.53(10)/sup 0/, ..beta.. = 104.23(10)/sup 0/, ..gamma.. = 110.72(10)/sup 0/, space group P1. Its structure has been determined from three dimensional X-ray data collected with an automatic diffractometer at room temperature and refined with full matrix methods to the final conventional R value = 0.038. The uranyl group does not enter into the 18-crown-6 cavity, but presents the usual hexacoordination in the equatorial plane where two water molecules and the bidentate nitrato groups are coordinated trans to each other. The whole structure is constituted by neutral UO/sub 2/(NO/sub 3/)/sub 2/(H/sub 2/O)/sub 2/ units alternated with 18-crown-6 molecules and linked together in infinite chains developing along (001) through a hydrogen bonding system. The cyclic ether assumes two statistically non-equivalent sites in the crystal (occupancy factor 0.7 and 0.3 respectively) related to each other by a 180/sup 0/ rotation about 0(7)...0(7') axis.

  17. Modelling available crown fuel for Pinus pinaster Ait. stands in the "Cazorla, Segura and Las Villas Natural Park" (Spain).

    Science.gov (United States)

    Molina, Juan Ramón; Rodríguez y Silva, Francisco; Mérida, Enrique; Herrera, Miguel Ángel

    2014-11-01

    One of the main limiting aspects in the application of crown fire models at landscape scale has been the uncertainty derived to describe canopy fuel stratum. Available crown fuel and canopy bulk density are essential in order to simulate crown fire behaviour and are of potential use in the evaluation of silvicultural treatments. Currently, the more accurate approach to estimate these parameters is to develop allometric models from common stand inventory data. In this sense, maritime pine (Pinus pinaster Aiton) trees were destructively sampled in the South of the Iberian Peninsula, covering natural and artificial stands. Crown fine fuel was separated into size classes and allometric equations that estimate crown fuel load by biomass fractions were developed. Available crown fuel was determined according to the fuel load differences between un-burned and burned trees with similar characteristics. Taking our destructive post-fire inventory into account, available crown fuel was estimated as the sum of needles biomass, 87.63% of the twigs biomass and 62.79% of the fine branches biomass. In spite of the differences between natural and artificial stands, generic models explained 82% (needles biomass), 89% (crown fuel), 92% (available crown fuel) and 94% (canopy bulk density) of the observed variation. Inclusion of the fitted models in fire management decision-making can provide a decision support system for assessing the potential crown fire of different silvicultural alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. OCT evaluation of single ceramic crowns: comparison between conventional and chair-side CAD/CAM technologies

    Science.gov (United States)

    Gabor, A.; Jivanescu, A.; Zaharia, C.; Hategan, S.; Topala, F. I.; Levai, C. M.; Negrutiu, M. L.; Sinescu, C.; Duma, V.-F.; Bradu, A.; Podoleanu, A. Gh.

    2016-03-01

    Digital impressions were introduced to overcome some of the obstacles due to traditional impression materials and techniques. The aim of this in vitro study is to compare the accuracy of all ceramic crowns obtained with digital impression and CAD-CAM technology with the accuracy of those obtained with conventional impression techniques. Two groups of 10 crowns each have been considered. The digital data obtained from Group 1 have been processed and the all-ceramic crowns were milled with a CAD/CAM technology (CEREC MCX, Sirona). The all ceramic crowns in Group 2 were obtained with the classical technique of pressing (emax, Ivoclar, Vivadent). The evaluation of the marginal adaptation was performed with Time Domain Optical Coherence Tomography (TD OCT), working at a wavelength of 1300 nm. Tri-dimensional (3D) reconstructions of the selected areas were obtained. Based on the findings in this study, one may conclude that the marginal accuracy of all ceramic crowns fabricated with digital impression and the CAD/CAM technique is superior to the conventional impression technique.

  19. Post and core build-ups in crown and bridge abutments: Bio-mechanical advantages and disadvantages.

    Science.gov (United States)

    Mamoun, John

    2017-06-01

    Dentists often place post and core buildups on endodontically treated abutments for crown and bridge restorations. This article analyzes the bio-mechanical purposes, advantages and disadvantages of placing a core or a post and core in an endodontically treated tooth and reviews literature on post and core biomechanics. The author assesses the scientific rationale of the claim that the main purpose of a post is to retain a core, or the claim that posts weaken teeth. More likely, the main function of a post is to help prevent the abutment, on which a crown is cemented, from fracturing such that the abutment separates from the tooth root, at a fracture plane that is located approximately and theoretically at the level of the crown (or ferrule) margin. A post essentially improves the ferrule effect that is provided by the partial fixed denture prosthesis. This paper also explores the difference between bio-mechanical failures of crowns caused by lack of retention or excess taper, versus failures due to a sub-optimal ferrule effect in crown and bridge prostheses.

  20. Lipophilic Chemicals from Diesel Exhaust Particles Trigger Calcium Response in Human Endothelial Cells via Aryl Hydrocarbon Receptor Non-Genomic Signalling

    Directory of Open Access Journals (Sweden)

    Bendik C. Brinchmann

    2018-05-01

    Full Text Available Exposure to diesel exhaust particles (DEPs affects endothelial function and may contribute to the development of atherosclerosis and vasomotor dysfunction. As intracellular calcium concentration [Ca2+]i is considered important in myoendothelial signalling, we explored the effects of extractable organic matter from DEPs (DEP-EOM on [Ca2+]i and membrane microstructure in endothelial cells. DEP-EOM of increasing polarity was obtained by pressurized sequential extraction of DEPs with n-hexane (n-Hex-EOM, dichloromethane (DCM-EOM, methanol, and water. Chemical analysis revealed that the majority of organic matter was extracted by the n-Hex- and DCM-EOM, with polycyclic aromatic hydrocarbons primarily occurring in n-Hex-EOM. The concentration of calcium was measured in human microvascular endothelial cells (HMEC-1 using micro-spectrofluorometry. The lipophilic n-Hex-EOM and DCM-EOM, but not the more polar methanol- and water-soluble extracts, induced rapid [Ca2+]i increases in HMEC-1. n-Hex-EOM triggered [Ca2+]i increase from intracellular stores, followed by extracellular calcium influx consistent with store operated calcium entry (SOCE. By contrast, the less lipophilic DCM-EOM triggered [Ca2+]i increase via extracellular influx alone, resembling receptor operated calcium entry (ROCE. Both extracts increased [Ca2+]i via aryl hydrocarbon receptor (AhR non-genomic signalling, verified by pharmacological inhibition and RNA-interference. Moreover, DCM-EOM appeared to induce an AhR-dependent reduction in the global plasma membrane order, as visualized by confocal fluorescence microscopy. DCM-EOM-triggered [Ca2+]i increase and membrane alterations were attenuated by the membrane stabilizing lipid cholesterol. In conclusion, lipophilic constituents of DEPs extracted by n-hexane and DCM seem to induce rapid AhR-dependent [Ca2+]i increase in HMEC-1 endothelial cells, possibly involving both ROCE and SOCE-mediated mechanisms. The semi-lipophilic fraction

  1. The use of phospholipid modified column for the determination of lipophilic properties in high performance liquid chromatography.

    Science.gov (United States)

    Godard, Tal; Grushka, Eli

    2011-03-04

    A new chromatographic stationary phase obtained by coating a reversed phase amide column with phosphatidylcholine based liposomes solution to yield a phospholipid modified column (PLM). The modification is achieved by the dynamic coating method which recycles the coating solution through the column in a closed loop for a period of 24 h. The chromatographic properties of the new column have changed significantly as compared to the original amide column due to the phospholipid coating. A good correlation was observed between n-octanol/water logP values and the logarithm of the retention factor obtained on the PLM column for a large number of solutes. In addition the PLM column was characterized using the linear solvation energy relationship (LSER). The values of the LSER system constants for the PLM column were calculated and were found to be very close to those of the n-octanol/water extraction system thus suggesting that the PLM column can be used for the estimation of n-octanol/water partition coefficient and serve as a possible alternative to the shake-flask method for lipophilicity determination. In addition, the results suggest that the PLM column can provide an alternative to other phospholipid-based column such as the IAM and the DPC columns. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Selectivity in stripping of alkali-metal cations from crown ether carboxylate complexes

    International Nuclear Information System (INIS)

    Bartsch, R.A.; Walkowiak, W.; Robison, T.W.

    1992-01-01

    To probe the effect of structural variations within the ionophore upon the efficiency and selectivity of solvent extraction, a variety of crown ether carboxylic acids and phosphonic acid monoesters have been synthesized. In other studies the influence of the organic diluent upon extraction efficiency and selectivity has been probed for such proton-ionizable crown ethers. In the present investigation, attention is focused upon selectivity in the stripping step. Although the efficiency of metal ion stripping is often examined in solvent extraction studies, the selectivity of competitive metal ion release under different conditions is much less frequently considered. In this study, competitive stripping of metal ions from chloroform solutions of five-alkali-metal crown ether carboxylates by varying concentrations of aqueous hydrochloric acid is examined. Alkali metals used were Li, Na, K, Rb, and Cs

  3. Simplified cementation of lithium disilicate crowns: Retention with various adhesive resin cement combinations.

    Science.gov (United States)

    Johnson, Glen H; Lepe, Xavier; Patterson, Amanda; Schäfer, Oliver

    2017-09-27

    A composite resin cement and matching self-etch adhesive was developed to simplify the dependable retention of lithium disilicate crowns. The efficacy of this new system is unknown. The purpose of this in vitro study was to determine whether lithium disilicate crowns cemented with a new composite resin and adhesive system and 2 other popular systems provide clinically acceptable crown retention after long-term aging with monthly thermocycling. Extracted human molars were prepared with a flat occlusal surface, 20-degree convergence, and 4 mm axial length. The axio-occlusal line angle was slightly rounded. The preparation surface area was determined by optical scanning and the analysis of the standard tessellation language (STL) files. The specimens were distributed into 3 cement groups (n=12) to obtain equal mean surface areas. Lithium disilicate crowns (IPS e.max Press) were fabricated for each preparation, etched with 9.5% hydrofluoric acid for 15 seconds, and cleaned. Cement systems were RelyX Ultimate with Scotch Bond Universal (3M Dental Products); Monobond S, Multilink Automix with Multilink Primer A and B (Ivoclar Vivadent AG); and NX3 Nexus with OptiBond XTR (Kerr Corp). Each adhesive provided self-etching of the dentin. Before cementation, the prepared specimens were stored in 35°C water. A force of 196 N was used to cement the crowns, and the specimens were polymerized in a 35°C oven at 100% humidity. After 24 hours of storage at 100% humidity, the cemented crowns were thermocycled (5°C to 55°C) for 5000 cycles each month for 6 months. The crowns were removed axially at 0.5 mm/min. The removal force was recorded and the dislodgement stress calculated using the preparation surface area. The type of cement failure was recorded, and the data were analyzed by 1-way ANOVA and the chi-square test (α=.05) after the equality of variances had been assessed with the Levene test. The Levene test was nonsignificant (P=.936). The ANOVA revealed the mean removal

  4. An in vitro evaluation of the integrity of stainless steel crown margins cemented with different luting agents.

    Science.gov (United States)

    Ettinger, R L; Kambhu, P P; Asmussen, C M; Damiano, P C

    1998-01-01

    The elderly population is retaining more teeth which require extensive restorations. The purpose of this study was to identify a luting agent which had the least marginal breakdown when used with stainless steel crowns. Thirty-six caries-free molars were selected, prepared for stainless steel crowns, and embedded in acrylic to support the crown and tooth. The crowns (Unitek/3M) were cemented with 4 different luting agents: (A) Fleck's Cement, (B) Ketac-Cem, (C) All-Bond C & B Cement, and (D) Panavia EX Cement. All the restored teeth were thermocycled and divided into 3 experimental groups. Twelve teeth were stained. The remaining teeth were occlusally loaded and stained. The remaining 12 teeth were thermocycled and stained again. The stainless steel crowns were then sectioned and photographed at 7.5x mag. The dye penetration was evaluated by measurement of the percentage of dye penetration from the crown margin to the cusp tip on each side. Statistical analysis found that the least dye penetration was with All-Bond C & B Cement (p = 0.0001). The most extensive penetration was observed in Ketac-Cem Occlusal loading was a significant factor (p = 0.0001) increasing the dye penetration, but the crown-tooth gap was not.

  5. Investigating the Influence of (Deoxy)fluorination on the Lipophilicity of Non-UV-Active Fluorinated Alkanols and Carbohydrates by a New log P Determination Method.

    Science.gov (United States)

    Linclau, Bruno; Wang, Zhong; Compain, Guillaume; Paumelle, Vincent; Fontenelle, Clement Q; Wells, Neil; Weymouth-Wilson, Alex

    2016-01-11

    Property tuning by fluorination is very effective for a number of purposes, and currently increasingly investigated for aliphatic compounds. An important application is lipophilicity (log P) modulation. However, the determination of log P is cumbersome for non-UV-active compounds. A new variation of the shake-flask log P determination method is presented, enabling the measurement of log P for fluorinated compounds with or without UV activity regardless of whether they are hydrophilic or lipophilic. No calibration curves or measurements of compound masses/aliquot volumes are required. With this method, the influence of fluorination on the lipophilicity of fluorinated aliphatic alcohols was determined, and the log P values of fluorinated carbohydrates were measured. Interesting trends and changes, for example, for the dependence on relative stereochemistry, are reported. © 2015 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

  6. A biological approach to crown fracture: Fracture reattachment - A report of two cases

    Directory of Open Access Journals (Sweden)

    K Vijayaprabha

    2012-01-01

    Full Text Available The development of adhesive dentistry has allowed dentists to use the patient′s own fragment to restore the fractured tooth, which is considered to be the most conservative method of treatment of crown fracture allowing restoration of original dental anatomy, thus rehabilitating function and esthetics in a short time by preserving dental tissues. The tooth fragment reattachment is preferred over full coverage crowns or composite resin restoration because it conserves sound tooth structure, and is more esthetic, maintaining the original anatomy and translucency, and the rate of incisal wear also matches that of original tooth structure. Presented here is a report of two cases of crown fracture managed by reattachment procedures.

  7. Lipophilic ester and amide derivatives of rosmarinic acid protect cells against H2O2-induced DNA damage and apoptosis: The potential role of intracellular accumulation and labile iron chelation

    Directory of Open Access Journals (Sweden)

    Paraskevi S. Gerogianni

    2018-05-01

    Full Text Available Phenolic acids represent abundant components contained in human diet. However, the negative charge in their carboxylic group limits their capacity to diffuse through biological membranes, thus hindering their access to cell interior. In order to promote the diffusion of rosmarinic acid through biological membranes, we synthesized several lipophilic ester- and amide-derivatives of this compound and evaluated their capacity to prevent H2O2-induced DNA damage and apoptosis in cultured human cells. Esterification of the carboxylic moiety with lipophilic groups strongly enhanced the capacity of rosmarinic acid to protect cells. On the other hand, the amide-derivatives were somewhat less effective but exerted less cytotoxicity at high concentrations. Cell uptake experiments, using ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS, illustrated different levels of intracellular accumulation among the ester- and amide-derivatives, with the first being more effectively accumulated, probably due to their extensive hydrolysis inside the cells. In conclusion, these results highlight the hitherto unrecognized fundamental importance of derivatization of diet-derived phenolic acids to unveil their biological potential.

  8. 18F-fluorination by crown ether-metal fluoride

    International Nuclear Information System (INIS)

    Irie, T.; Fukushi, K.; Ido, T.; Kasida, Y.; Nozaki, T.

    1984-01-01

    For non-carrier-added 18 F-labeling of organic compounds, details were studied concerning the previously developed KF-crown ether method. In the modified method, a minute amount of KOH instead of carrier KF is added for the preparation of the anhydrous 18 F from aqueous carrier-free 18 F. The following factors were examined in order to determine optimum conditions for the preparation of the anhydrous non-carrier-added 18 F and the labeling synthesis with it: effects of the vessel on the evaporation of the 18 F-KOH solution and the amount of added KOH for the conversion of aqueous 18 F to anhydrous 18 F, the solubilized activity of the 18 F obtained by the evaporation in organic solutions containing 18-Crown-6 and the labeling reaction, as exemplified by the synthesis of 21-fluoroprogesterone. (author)

  9. [Survival rate of IPS-Empress 2 all-ceramic crowns and bridges: three year's results].

    Science.gov (United States)

    Zimmer, Doris; Gerds, Thomas; Strub, Jörg R

    2004-01-01

    The objective of this prospective clinical study was to calculate the survival rate of IPS-Empress2 crowns and fixed partial dentures (FPD) over a three-year period. In 43 patients 27 IPS-Empress2 crowns and 31 fixed partial dentures were adhesively luted. Crowns were placed on premolars and molars and FPDs were inserted in the anterior and premolar area. Abutments were prepared with a circular 1.2 mm wide shoulder. The clinical follow-up examination took place after 6, 12, 24, 36 and 48 months. After a mean of 38 months, the survival rate (Kaplan-Meier) of all-ceramic crowns was 100% and of the three unit FDP 72.4%. There were a total of six complete failures which occurred only with the three-unit IPS-Empress2 FPDs. Three FPDs exhibited fractures of the framework for which the manufacturer's instructions of connector-dimension was not satisfied, and one FPD exhibited an irreparable incomplete veneer fracture. Further two FPDs showed biological failures. The accuracy of fit and esthetics were clinically satisfactory. The three-year results showed the IPS-Empress2-ceramic as an adequate all-ceramic material for single crowns. The use for FPD needs further critical consideration.

  10. Nanoemulsion-based delivery systems to improve functionality of lipophilic components

    Directory of Open Access Journals (Sweden)

    ISABEL eODRIOZOLA-SERRANO

    2014-12-01

    Full Text Available The use of active lipophilic substances such as antimicrobials and health-related compounds in the food industry still is a challenge due to their poor water-solubility and instability in food formulations. Nano-sized structures such as nanoemulsions of oil-in-water are regarded as useful tools with a great potential in the food sector to incorporate food ingredients. Reducing the size of the active compounds incorporated within a solution would increase the surface area per mass unit of nanoemulsions thus enhancing solubility and stability in foods. In addition, the ability of the active lipids to penetrate across biological membranes is also enhanced, thus boosting their biological functionality. An overview of the most significant studies reporting data about the potential benefits of active lipid nanoemulsions over conventional emulsions is presented.

  11. Comparison of 3D displacements of screw-retained zirconia implant crowns into implants with different internal connections with respect to screw tightening.

    Science.gov (United States)

    Rebeeah, Hanadi A; Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin; Clelland, Nancy; Brantley, William

    2018-01-01

    Internal conical implant-abutment connections without horizontal platforms may lead to crown displacement during screw tightening and torque application. This displacement may affect the proximal contacts and occlusion of the definitive prosthesis. The purpose of this in vitro study was to evaluate the displacement of custom screw-retained zirconia single crowns into a recently introduced internal conical seal implant-abutment connection in 3D during hand and torque driver screw tightening. Stereolithic acrylic resin models were printed using computed tomography data from a patient missing the maxillary right central incisor. Two different internal connection implant systems (both ∼11.5 mm) were placed in the edentulous site in each model using a surgical guide. Five screw-retained single zirconia computer-aided design and computer-aided manufacturing (CAD-CAM) crowns were fabricated for each system. A pair of high-resolution digital cameras was used to record the relationship of the crown to the model. The crowns were tightened according to the manufacturers' specifications using a torque driver, and the cameras recorded their relative position again. Three-dimensional image correlation was used to measure and compare crown positions, first hand tightened and then torque driven. The displacement test was repeated 3 times for each crown. Commercial image correlation software was used to extract the data and compare the amount of displacement vertically, mesiodistally, and buccolingually. Repeated-measures ANOVA calculated the relative displacements for all 5 specimens for each implant for both crown screw hand tightening and after applied torque. A Student t test with Bonferroni correction was used for pairwise comparison of interest to determine statistical differences between the 2 implants (α=.05). The mean vertical displacements were statistically higher than the mean displacements in the mesiodistal and buccolingual directions for both implants

  12. Management of complicated crown-root fracture in central incisors using intentional replantation with 180° rotation: A case report

    Directory of Open Access Journals (Sweden)

    Reyhaneh Faghihian

    2017-01-01

    Full Text Available Introduction: Complicated crown-root fractures are rare and their treatment is complex. Numerous methods such as crown lengthening and orthodontic or surgical extrusion have been described for the treatment of crown-root fracture. The aim of this study was to report managing complicated crown-root fracture using intentional replantation with 180° rotation. Case report: This case report demonstrates successful management of complicated crown-root fracture in central incisor of a 10-year-old boy using intentional replantation with 180° rotation. Discussion: At 18-month follow-up, the replanted tooth revealed normal function with no obvious resorption.

  13. Hydrophilic-lipophilic balanced magnetic nanoparticles: preparation and application in magnetic solid-phase extraction of organochlorine pesticides and triazine herbicides in environmental water samples.

    Science.gov (United States)

    He, Zeying; Wang, Peng; Liu, Donghui; Zhou, Zhiqiang

    2014-09-01

    In this study, a novel hydrophilic-lipophilic balanced magnetic nanoparticle, magnetic poly(divinylbenzene-co-N-vinylpyrrolidone) (HLB-MPNP) was successfully synthesized and applied for the extraction and determination of triazine and organochlorine pesticides in environmental water samples. The specific ratio of two monomers, hydrophilic N-vinylpyrrolidone and lipophilic divinylbenzene, endowed the magnetic nanoparticles with hydrophilic-lipophilic balanced character, which made it capable of extracting both polar and nonpolar analytes. The experimental parameters affecting extraction efficiency, including desorption conditions, sample pH, sample volume and extraction time were investigated and optimized. Under the optimum conditions, good linearity was obtained in the range of 0.20-10 μg L(-1) for triazine herbicides and 5.0-100 ng L(-1) for organochlorine pesticides, with correlation coefficients ranging from 0.994 to 0.999. The limits of determination were between 0.048 and 0.081 μg L(-1) for triazine herbicides and 0.39 and 3.26 ng L(-1) for organochlorine pesticides. The proposed method was successfully applied in the analysis of triazine and organochlorine pesticides in environmental water samples (ground, river and reservoir). Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Solvent extraction of technetium from alkaline waste media using bis-4,4'(5')[(tert-butyl)cyclohexano]-18-crown-6

    International Nuclear Information System (INIS)

    Bonnesen, P.V.; Presley, D.J.; Moyer, B.A.

    1995-01-01

    The crown ether bis-4,4'(5')[(tert-butyl)cyclohexano]-18-crown-6 can be utilized in a solvent-extraction process for the removal of technetium as pertechnetate ion, TcO 4 - from solutions simulating highly radioactive alkaline defense wastes (''tank wastes'') stored at several sites in the United States. The process employs non-halogenated and non-volatile diluents and modifiers and includes an efficient stripping procedure using only water. More than 95% of the pertechnetate present at 6 x 10 -5 M in Melton Valley (Oak Ridge, TN) and Hanford (Washington) tank-waste simulants was removed following two cross-current extraction contacts using 0.02 M bis-4,4'(5')[(tertbutyl)cyclohexano]- 18-crown-6 in 2:1 vol/vol TBP/Isopar reg-sign M diluent at 25 C. Similarly, for both simulants, more than 98% of the pertechnetate contained in the solvent was back-extracted following two cross-current stripping contacts using deionized water

  15. Evaluation of the Prevalence of Different Treatment Failure Modes after Crown Lengthening Surgical Procedures

    Directory of Open Access Journals (Sweden)

    Amirreza Babaloo

    2016-07-01

    Full Text Available Introduction: Preservation of the health of periodontium is very important for the long-term success of restored teeth and a balance should always be created between the patients’ esthetic requirements and the periodontal health. Failures of crown lengthening procedures are classified into early and late failures. The aim of this study was to evaluate the prevalence of early failures of crown leathering surgical procedures. Materials and methods: In this descriptive/cross-sectional study, 96 patients were selected from those referring to the Department of Periodontitis, Tabriz Faculty of Dentistry, who required crown lengthening procedures. The particulars of these patients were recorded in special forms and the reasons for the failure of surgical procedures were separately determined at 2- and 6-week intervals. In addition, the frequencies of the reasons for failures were determined in percentages and absolute frequencies. Data were analyzed with descriptive statistics (frequencies and percentages using SPSS 21. Statistical significance was set at P<0.05. Results: Evaluation of patients 6 weeks after surgery showed a failure rate of 14.5% for crown lengthening procedures in patients referring to the Department of Periodontics, Tabriz Faculty of Dentistry. The most common reasons for such early failures in the 6th week, in descending order, were a lack of sufficient keratinized gingiva around in tooth in question, fracture of the tooth structure after surgery, inadequate surgery (not creating a proper distance between the healthy margin and the crest and the coronal returning of the gingival tissue on the tooth. A lack of sufficient keratinized gingiva around the tooth was the most frequent reason for the early failure of crown lengthening procedure at both study intervals. Conclusion: It can be concluded from the results of the present study that during the 6th postoperative week the crown lengthening procedures exhibited a 14.5% failure rate

  16. Inhibition of human dendritic cell activation by hydroethanolic but not lipophilic extracts of turmeric (Curcuma longa).

    Science.gov (United States)

    Krasovsky, Joseph; Chang, David H; Deng, Gary; Yeung, Simon; Lee, Mavis; Leung, Ping Chung; Cunningham-Rundles, Susanna; Cassileth, Barrie; Dhodapkar, Madhav V

    2009-03-01

    Turmeric has been extensively utilized in Indian and Chinese medicine for its immune-modulatory properties. Dendritic cells (DCs) are antigen-presenting cells specialized to initiate and regulate immunity. The ability of DCs to initiate immunity is linked to their activation status. The effects of turmeric on human DCs have not been studied. Here we show that hydroethanolic (HEE) but not lipophilic "supercritical" extraction (SCE) of turmeric inhibits the activation of human DCs in response to inflammatory cytokines. Treatment of DCs with HEE also inhibits the ability of DCs to stimulate the mixed lymphocyte reaction (MLR). Importantly, the lipophilic fraction does not synergize with the hydroethanolic fraction for the ability of inhibiting DC maturation. Rather, culturing of DCs with the combination of HEE and SCE leads to partial abrogation of the effects of HEE on the MLR initiated by DCs. These data provide a mechanism for the anti-inflammatory properties of turmeric. However, they suggest that these extracts are not synergistic and may contain components with mutually antagonistic effects on human DCs. Harnessing the immune effects of turmeric may benefit from specifically targeting the active fractions.

  17. Antioxidant activity and possible bioactive components in hydrophilic and lipophilic fractions from the seaweed Halimeda incrassata

    Directory of Open Access Journals (Sweden)

    Alexis Vidal Novoa

    2011-02-01

    Full Text Available Hydrophilic and lipophilic fractions, obtained from the marine algae Halimeda incrassata (J.Ellis J.V.Lamouroux, Halimedaceae, were studied by using the ²-carotene-linoleate assay system. In case of hydrophilic fractions, the total phenolic compounds were quantified and two of their components were identified as salicylic and ferulic acids. From the lipophilic fraction, fatty acid composition was studied. The highest antioxidant activities values were found on the polar fractions containing phenolic acids. The total phenolics content on the hydrophilic fractions was 255 μg of gallic acid equivalents/g of fresh seaweed. To further characterize H. incrassata chemical composition, the total lipid content was quantified (7.4 mg per gram of dried algae as well as the saturated and unsaturated fatty acids ratio (1:1.46. In summary, this paper adds more convincing evidences in support of the antioxidant abilities of the lyophilized aqueous extract of Halimeda incrassata and it also relates this bioactivity, for the first time, with particular phenolic components of the extract. Altogether, these results represent another step towards the use of this natural product as drug candidates.

  18. Reducing the risk of sensitivity and pulpal complications after the placement of crowns and fixed partial dentures.

    Science.gov (United States)

    Brännström, M

    1996-10-01

    Sensitivity after cementation of a crown with glass-ionomer cement is often attributed to an adverse effect on the pulp by the luting agent. Most permanent restorative materials in common use today do not tend to irritate the pulp; the main cause of pulpal damage is infection, the bacteria originating in the smear layer or deep in the dental tubules, inaccessible to caries-excavating procedures. A poorly fitting provisional crown may expose cut dentin to the oral fluids, and mechanical trauma caused by frictional heat during preparation may also damage the pulp. The following precautions are recommended during precementation procedures to reduce the risk of an inflammatory response in the pulp: (1) The provisional crown should be well fitting, covering cervical dentin but not impinging on the periodontal tissues. The permanent crown should be cemented as soon as possible. (2) The superficial smear layer should be removed and the dentinal surface should be treated with an antibacterial solution before the provisional crown is placed. (3) To decrease dentinal permeability under the provisional crown, the dentinal surface should be covered with a liner that can be easily removed before final cementation. (4) to ensure optimal mircomechanical bonding, the dentinal surface should be thoroughly cleaned, and the dentin should be kept moist until cementation. (5) The occlusion should be carefully checked before cementation of the crown.

  19. Swimming black-crowned night-herons (Nycticorax nycticorax) Kleptoparasitize American coots (Fulica americana)

    DEFF Research Database (Denmark)

    Graves, Gary R.

    2015-01-01

    I observed black-crowned night-herons (Nycticorax nycticorax) swimming and kleptoparasitizing American coots (Fulica americana) at an artificial lake in Pinal County, Arizona. This appears to be the first record of interspecific kleptoparasitism by a swimming ardeid.......I observed black-crowned night-herons (Nycticorax nycticorax) swimming and kleptoparasitizing American coots (Fulica americana) at an artificial lake in Pinal County, Arizona. This appears to be the first record of interspecific kleptoparasitism by a swimming ardeid....

  20. Crown heights in the permanent teeth of 45,X and 45,X/46,XX females.

    Science.gov (United States)

    Pentinpuro, Raija Helena; Lähdesmäki, Raija Eliisa; Niinimaa, Ahti Olavi; Pesonen, Paula Ritva Orvokki; Alvesalo, Lassi Juhani

    2014-11-01

    Previous results regarding human sex chromosome aneuploidies have shown that the X and Y chromosomes affect tooth size and morphology. This study looked for the effect of sex chromosome deficiency on permanent tooth crown heights. The material, from the Finnish KVANTTI Research Project, consisted of 97 45,X females and 15 45,X/46,XX females. The controls were 32 sisters and 28 mothers of the 45,X females, eight sisters and two mothers of the 45,X/46,XX females and 35 female population controls. Crown heights of all the available teeth except third molars on both sides of the jaws were measured from panoramic radiographs with a digital calliper according to the defined procedure. The tooth crown heights were significantly smaller in the 45,X females than in the female population controls, except for the incisors and one canine in the maxilla, whereas the tooth crown heights of the 45,X/46,XX females were close to those of the normal control females. The differences between the 45,X and 45,X/46,XX females were statistically significant, excluding the upper incisor area and a few teeth in the mandible. The effect of the sex chromosome deficiency on permanent tooth crown height is due to the magnitude of lacking sex chromosome material. The present results regarding the 45,X females are parallel to previous findings in Turner patients regarding reduced mesiodistal and labiolingual dimensions and tooth crown heights in the permanent dentition.

  1. STRUCTURE AND THERMAL STABILITY OF THE BENZO-15-CROWN-5 WITH LANTHANUM (III BROMIDE COMPLEX

    Directory of Open Access Journals (Sweden)

    Muhammad Idiris Saleh

    2010-06-01

    Full Text Available The reaction of benzo-15-crown-5 (C14H20O5 ligand with La(NO33.7H2O in the presence of HBr has resulted in the production of an exotic sandwich complex, [LaC28H36Br4O10][3Br]. The crystal system is triclinic with space group P1, a = 12.5834(14 Å, b = 13.5816(16 Å, c = 13.8403(16 Å, a = 70.751(2°, b = 66.773(2° and g = 67.631(2°. The cation comprises of the lanthanum atom coordinated to two crowns via three oxygen atoms from each crown in a η3-sandwich fashion. The two phenyl groups of the crown are brominated. The La-OLigand bond lengths are between 2.857(7 and 2.949(7 Å. The trianion [3Br]3- is linear with Br-Br bond lengths of 2.518(2 and 2.560(2 Å respectively. The molecule is stabilized by intermolecular interactions of the type C-H...Br to form dimers and are arranged parallel to bc face.  Keywords: lanthanum, benzo-15-crown-5, hydrogen bonding, bromination, x-ray structure

  2. Lipophilic phosphorescent gold(I) clusters as selective probes for visualization of lipid droplets by two-photon microscopy

    Czech Academy of Sciences Publication Activity Database

    Koshel, E. I.; Cheluskin, P. S.; Melnikov, A. S.; Serdobintsev, P. Y.; Stolbovaia, A. Y.; Saifitdinova, A. F.; Scheslavskiy, V. I.; Chernyavskiy, Oleksandr; Gaginskaya, E. R.; Koshevoy, I. O.; Tunik, S. P.

    2017-01-01

    Roč. 332, Jan 1 (2017), s. 122-130 ISSN 1010-6030 R&D Projects: GA MŠk(CZ) LM2015062 Institutional support: RVO:67985823 Keywords : polynuclear gold-alkynyl cluster * lipophilic probe * phosphorescence * adipocyte * two-photon microscopy * PLIM Subject RIV: EB - Genetics ; Molecular Biology OBOR OECD: Medical laboratory technology (including laboratory samples analysis Impact factor: 2.625, year: 2016

  3. Crystal structures of dioxonium hexafluorotantalate and dioxonium hexafluoroniobate complexes with tetrabenzo-30-crown-10

    Energy Technology Data Exchange (ETDEWEB)

    Furmanova, N. G., E-mail: furm@ns.crys.ras.ru; Rabadanov, M. Kh.; Chernaya, T. S. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Fonari, M. S., E-mail: fonari.xray@phys.asm.md; Simonov, Yu. A. [Academy of Sciences of Moldova, Institute of Applied Physics (Moldova, Republic of); Ganin, E. V., E-mail: edganin@yahoo.com [Ministry of Education and Science and National Academy of Sciences of Ukraine, Odessa State Environmental University (Ukraine); Gelmboldt, V. O., E-mail: eksvar@ukr.net [Ministry of Education and Science and National Academy of Sciences of Ukraine, Physicochemical Institute for Human and Environmental Protection (Ukraine); Grigorash, R. Ya.; Kotlyar, S. A.; Kamalov, G. L., E-mail: kamalov@ukr.net.ua [National Academy of Sciences of Ukraine, Bogatsky Physicochemical Institute (Ukraine)

    2008-03-15

    Two isostructural complexes of dioxonium [H{sub 5}O{sub 2}]{sup +} with tetrabenzo-30-crown-10 of the compositions [(tetrabenzo-30-crown-10 {center_dot} H{sub 5}O{sub 2})][TaF{sub 6}] (I) and [(tetrabenzo-30-crown-10 {center_dot} H{sub 5}O{sub 2})][NbF{sub 6}] (II) are studied using X-ray diffraction. The complexes crystallize in the monoclinic crystal system (space group C2/c, Z = 4). The unit cell parameters of these compounds are as follows: a = 15.6583(12) Angstrom-Sign , b = 15.2259(13) Angstrom-Sign , c = 16.4473(13) Angstrom-Sign , and {beta} = 99.398(6) Degree-Sign for complex I and a = 15.7117(12) Angstrom-Sign , b = 15.2785(15) Angstrom-Sign , c = 16.5247(15) Angstrom-Sign , and {beta} = 99.398(7) Degree-Sign for complex II. These complexes belong to the ionic type. The dioxonium cation [H{sub 5}O{sub 2}]{sup +} in the form of the two-unit cluster [H{sub 3}O {center_dot} H{sub 2}O]{sup +} is stabilized by the strong hydrogen bond OH Midline-Horizontal-Ellipsis O [O Midline-Horizontal-Ellipsis O, 2.353(4) Angstrom-Sign ] and encapsulated by the crown ether. Each oxygen atom of the dioxonium cation also forms two oxygen bonds O Midline-Horizontal-Ellipsis O(crown). The crown ether adopts an unusual two-level (pocket-like) conformation, which provides a complete encapsulation of the oxonium associate. The interaction of the cationic complex with the anion in the crystal occurs through contacts of the C-H Midline-Horizontal-Ellipsis F type.

  4. Engineering and validation of a novel lipid thin film for biomembrane modeling in lipophilicity determination of drugs and xenobiotics

    Directory of Open Access Journals (Sweden)

    Ogbonna Udochi

    2009-09-01

    Full Text Available Abstract Background Determination of lipophilicity as a tool for predicting pharmacokinetic molecular behavior is limited by the predictive power of available experimental models of the biomembrane. There is current interest, therefore, in models that accurately simulate the biomembrane structure and function. A novel bio-device; a lipid thin film, was engineered as an alternative approach to the previous use of hydrocarbon thin films in biomembrane modeling. Results Retention behavior of four structurally diverse model compounds; 4-amino-3,5-dinitrobenzoic acid (ADBA, naproxen (NPX, nabumetone (NBT and halofantrine (HF, representing 4 broad classes of varying molecular polarities and aqueous solubility behavior, was investigated on the lipid film, liquid paraffin, and octadecylsilane layers. Computational, thermodynamic and image analysis confirms the peculiar amphiphilic configuration of the lipid film. Effect of solute-type, layer-type and variables interactions on retention behavior was delineated by 2-way analysis of variance (ANOVA and quantitative structure property relationships (QSPR. Validation of the lipid film was implemented by statistical correlation of a unique chromatographic metric with Log P (octanol/water and several calculated molecular descriptors of bulk and solubility properties. Conclusion The lipid film signifies a biomimetic artificial biological interface capable of both hydrophobic and specific electrostatic interactions. It captures the hydrophilic-lipophilic balance (HLB in the determination of lipophilicity of molecules unlike the pure hydrocarbon film of the prior art. The potentials and performance of the bio-device gives the promise of its utility as a predictive analytic tool for early-stage drug discovery science.

  5. Crown ratio influences allometric scaling in trees

    Science.gov (United States)

    Annikki Makela; Harry T. Valentine

    2006-01-01

    Allometric theories suggest that the size and shape of organisms follow universal rules, with a tendency toward quarter-power scaling. In woody plants, however, structure is influenced by branch death and shedding, which leads to decreasing crown ratios, accumulation of heartwood, and stem and branch tapering. This paper examines the impacts on allometric scaling of...

  6. Internal fit of pressed and computer-aided design/computer-aided manufacturing ceramic crowns made from digital and conventional impressions.

    Science.gov (United States)

    Anadioti, Evanthia; Aquilino, Steven A; Gratton, David G; Holloway, Julie A; Denry, Isabelle L; Thomas, Geb W; Qian, Fang

    2015-04-01

    No studies have evaluated the internal adaptation of pressed and milled ceramic crowns made from digital impressions. The purpose of this in vitro study was to evaluate the internal fit of pressed and milled ceramic crowns made from digital and conventional impressions. Thirty polyvinyl siloxane (PVS) impressions and 30 Lava COS impressions made of a prepared dentoform tooth (master die) were fabricated. Thirty crowns were pressed in lithium disilicate (IPS e.max Press), and 30 crowns were milled from lithium disilicate blocks (IPS e.max CAD) (15/impression technique) with the E4D scanner and milling engine. The master die and the intaglio of the crowns were digitized with a 3-dimensional laser coordinate measurement machine. The digital master die and intaglio of each crown were merged. The distance between the die and the intaglio surface of the crown was measured at 3 standardized points. One-way ANOVA was used for statistical analysis (α=.05). One-way ANOVA revealed that the internal gap obtained from the Lava/press group (0.211 mm, ±SD 0.041) was significantly greater than that obtained from the other groups (Pdigital impression and pressed crown produced the least accurate internal fit. Copyright © 2015. Published by Elsevier Inc.

  7. Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology.

    Science.gov (United States)

    Pradíes, Guillermo; Zarauz, Cristina; Valverde, Arelhys; Ferreiroa, Alberto; Martínez-Rus, Francisco

    2015-02-01

    The aim of this study was to compare the fit of ceramic crowns fabricated from conventional silicone impressions with the fit of ceramic crowns fabricated from intraoral digital impressions. Twenty-five participants with 30 posterior teeth with a prosthetic demand were selected for the study. Two crowns were made for each preparation. One crown was fabricated from an intraoral digital impression system (IDI group) and the other crown was fabricated from a conventional two-step silicone impression (CI group). To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation with ultra-flow silicone. Each crown was embedded in acrylic resin to stabilise the registered interface and then cut in 2mm thick slices in a buco-lingual orientation. The internal gap was determined as the vertical distance from the internal surface of the crown to the prepared tooth surface at four points (marginal gap, axial gap, crest gap, and occlusal fossa gap) using stereomicroscopy with a magnification of 40×. Data was analysed by using Wilcoxon signed rank test (α=0.05). Internal adaptation values were significantly affected by the impression technique (p=0.001). Mean marginal gap was 76.33 ± 65.32 μm for the crowns of the IDI group and 91.46 ± 72.17 μm for the CI group. All-ceramic crowns fabricated from intraoral digital impressions with wavefront sampling technology demonstrated better internal fit than crowns manufactured from silicone impressions. Impressions obtained from an intraoral digital scanner based on wavefront sampling technology can be used for manufacturing ceramic crowns in the normal clinical practice with better results than conventional impressions with elastomers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. First report of Fusarium redolens causing crown rot of wheat (Triticum spp.) in Turkey

    Science.gov (United States)

    Fusarium crown rot, caused by a complex of Fusarium spp., is a yield-limiting disease of wheat world-wide, especially in dry Mediterranean climates. In order to identify Fusarium species associated with crown rot of wheat, a survey was conducted in summer 2013 in the major wheat growing regions of T...

  9. Surgical crown lengthening: a 12-month study - radiographic results

    Directory of Open Access Journals (Sweden)

    Daniela Eleutério Diniz

    2007-08-01

    Full Text Available OBJECTIVE: The purpose of this study was to perform a radiographic follow-up evaluation after a 12-month healing period, following crown lengthening surgery. MATERIAL AND METHODS: Twenty-three periodontally healthy subjects (mean age 32.5 years that required crown lengthening surgery in premolars were recruited. In a total of 30 premolars, full thickness flaps, osseous resection, and flap suturing were performed. The restorative margin was defined in the pre-surgical phase and maintained unaltered during the healing period, serving as a reference point. Standardized bitewing radiographs were taken before and after osseous reduction, and at 2, 3, 6, and 12-month healing periods. RESULTS: Intact lamina dura was observed at both mesial and distal alveolar crests only from the 3rd month. At 12-months, all alveolar crests presented lamina dura. The overall mean distance from the restorative margin to the alveolar crest achieved after osseous resection was 3.28±0.87 mm at mesial and 2.81±0.51 mm at distal sites. No significant radiographic changes in the bone crest were observed during a 12-month healing period. CONCLUSION: The findings of this study suggest that the radiographic proximal bone level observed on bitewing radiographs following crown lengthening surgery can be used as a reference to predict the future level of the healed alveolar crest.

  10. Management of horizontal crown fracture caused by traumatic injury with endorestoration treatment

    Directory of Open Access Journals (Sweden)

    Nanik Zubaidah

    2011-09-01

    Full Text Available Background: Traumatic injuries of teeth are the main cause of emergency treatment in dental practice. The horizontal crown fracture more frequently observed usually occurs in maxillary anterior region and young male patients. The most common type of coronal fracture is in the middle third, followed by root and apical part. Purpose: The aim of this case report is to present the management of crown fracture of teeth with pulp exposure caused by dental trauma with endorestoration treatment in order to reconstruct the shape and the function of the teeth. Case: A 22 years old male with horizontal crown fracture of anterior teeth. The patient asked for aesthetic dental treatment both for its form and function. Case management: This horizontal crown fracture of anterior teeth with pulp exposure caused by dental trauma still could be reconstructed, mainly by endorestoration treatment. The endodontic treatment with post and core insertion in the root canal then would increase its retention. Later, the porcelain crown would aesthetically recover its original form and function, therefore, it would improve the patient’s confidence and teeth function. Conclusion:  Endorestoration treatment on anterior teeth with harizontal crown fractures and pulp exposure is able to recover the normal function, aesthetic, and self-confidence.Latar belakang: Trauma pada gigi merupakan penyebab utama perawatan darurat dalam praktek dokter gigi. Fraktur mahkota horisontal pada umunya terjadi pada gigi anterior rahang atas dan terjadi pada penderita pria muda. Jenis yang paling sering dari fraktur mahkota adalah pada sepertiga tengah, daerah akar dan apical. Tujuan: Laporan kasus ini menjelaskan penatalaksanaan fraktur mahkota gigi dengan pulpa terbuka akibat trauma dengan perawatan endorestorasi untuk mengembalikan bentuk dan fungsi gigi. Kasus: Penderita pria umur 22 tahun dengan fraktur mahkota horizontal pada gigi anterior. Penderita tersebut menginginkan perawatan

  11. RICHMOND CROWN - FOR RESTORATION OF BADLY MUTILATED POSTERIOR TEETH : A CASE REPORT

    OpenAIRE

    Yadav; Swetha

    2015-01-01

    Restoration of badly broken endodontically treated teeth is a common problem in restorative dentistry. Such teeth often require additional support from the root canal by means of a post and core restoration. In cases where tooth structure is significantly lost full coverage restorations for posterior teeth are necessary to achieve proper tooth form and function. Badly broken teeth with minimal or no crown structure require added retention and support. The Richmond crown can be a good treatmen...

  12. Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology.

    Science.gov (United States)

    Huang, Zhuoli; Zhang, Lu; Zhu, Jingwei; Zhang, Xiuyin

    2015-06-01

    Selective laser melting (SLM) technology has been introduced to fabricate dental restorations. However, the fit of these restorations still needs further study. The purpose of this in vivo investigation was to compare the marginal and internal fit of SLM metal ceramic crowns with 2 lost-wax cast metal ceramic crowns and to evaluate the influence of tooth type on the marginal and internal fit of these crowns. A total of 330 metal ceramic crowns were evaluated. The metal copings were fabricated with SLM Co-Cr, cast Au-Pt, and cast Co-Cr alloy (n=110). The marginal and internal gaps of crowns were recorded by using a replica technique. The anterior and premolar replicas were sectioned 2 times, and molar replicas were sectioned 4 times. The marginal and internal gap width of each cross section was examined by stereomicroscope at ×30 magnification. Two-way analysis of variance was performed to identify the statistical difference among the groups. The marginal fit of the SLM Co-Cr group (75.6 ±32.6 μm) was not different from the cast Au-Pt group (76.8 ±32.1 μm) (P>.05) but was better than the cast Co-Cr group (91.0 ±36.3 μm) (P.05). The mean occlusal gap width of the SLM Co-Cr group (309.8 ±106.6 μm) was significantly higher than that of the cast Au-Pt group (254.6 ±109.6 μm) and the cast Co-Cr group (249.6 ±110.4 μm) (P.05). Also, no significant difference was found in the axial fit among the anterior group (138.3 ±52.5 μm), the premolar group (132.9 ±50.4 μm), and the molar group (134.4 ±52.5 μm) (P>.05). The anterior group (267.6 ±110.2 μm) did not differ from the premolar group (270.2 ±112.8 μm) and the molar group (268.6 ±110.5 μm) in occlusal fit (P>.05). The marginal fit of SLM Co-Cr metal ceramic crowns was similar to that of the cast Au-Pt metal ceramic crowns and was better than that of the cast Co-Cr metal ceramic crowns. The SLM Co-Cr metal ceramic crowns were not significantly different from the 2 cast metal ceramic crowns in axial

  13. A novel transferable individual tree crown delineation model based on Fishing Net Dragging and boundary classification

    Science.gov (United States)

    Liu, Tao; Im, Jungho; Quackenbush, Lindi J.

    2015-12-01

    This study provides a novel approach to individual tree crown delineation (ITCD) using airborne Light Detection and Ranging (LiDAR) data in dense natural forests using two main steps: crown boundary refinement based on a proposed Fishing Net Dragging (FiND) method, and segment merging based on boundary classification. FiND starts with approximate tree crown boundaries derived using a traditional watershed method with Gaussian filtering and refines these boundaries using an algorithm that mimics how a fisherman drags a fishing net. Random forest machine learning is then used to classify boundary segments into two classes: boundaries between trees and boundaries between branches that belong to a single tree. Three groups of LiDAR-derived features-two from the pseudo waveform generated along with crown boundaries and one from a canopy height model (CHM)-were used in the classification. The proposed ITCD approach was tested using LiDAR data collected over a mountainous region in the Adirondack Park, NY, USA. Overall accuracy of boundary classification was 82.4%. Features derived from the CHM were generally more important in the classification than the features extracted from the pseudo waveform. A comprehensive accuracy assessment scheme for ITCD was also introduced by considering both area of crown overlap and crown centroids. Accuracy assessment using this new scheme shows the proposed ITCD achieved 74% and 78% as overall accuracy, respectively, for deciduous and mixed forest.

  14. Solid phase extraction for removal of matrix effects in lipophilic marine toxin analysis by liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Gerssen, A.; McElhinney, M.; Mulder, P.P.J.; Bire, R.; Hess, P.; Boer, de J.

    2009-01-01

    The potential of solid phase extraction (SPE) clean-up has been assessed to reduce matrix effects (signal suppression or enhancement) in the liquid chromatography-tandem mass spectrometry (LC¿MS/MS) analysis of lipophilic marine toxins. A large array of ion-exchange, silica-based, and mixed-function

  15. Solid phase extraction for removal of matrix effects in lipophilic marine toxin analysis by liquid chromatography-tandem mass spectrometry

    NARCIS (Netherlands)

    Gerssen, A.; McElhinney, A. M.; Mulder, P.P.J.; Bire, L.; Hess, P.; de Boer, J.

    2009-01-01

    The potential of solid phase extraction (SPE) clean-up has been assessed to reduce matrix effects (signal suppression or enhancement) in the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of lipophilic marine toxins. A large array of ion-exchange, silica-based, and mixed-function

  16. Dentist Material Selection for Single-Unit Crowns: Findings from The National Dental Practice-Based Research Network

    Science.gov (United States)

    Makhija, Sonia K.; Lawson, Nathaniel C.; Gilbert, Gregg H.; Litaker, Mark S.; McClelland, Jocelyn A.; Louis, David R.; Gordan, Valeria V.; Pihlstrom, Daniel J.; Meyerowitz, Cyril; Mungia, Rahma; McCracken, Michael S.

    2016-01-01

    Objectives Dentists enrolled in the National Dental Practice-Based Research Network completed a study questionnaire about techniques and materials used for single-unit crowns and an enrollment questionnaire about dentist/practice characteristics. The objectives were to quantify dentists’ material recommendations and test the hypothesis that dentist’s and practice’s characteristics are significantly associated with these recommendations. Methods Surveyed dentists responded to a contextual scenario asking what material they would use for a single-unit crown on an anterior and posterior tooth. Material choices included: full metal, porcelain-fused-to-metal (PFM), all-zirconia, layered zirconia, lithium disilicate, leucite-reinforced ceramic, or other. Results 1,777 of 2,132 eligible dentists responded (83%). The top 3 choices for anterior crowns were lithium disilicate (54%), layered zirconia (17%), and leucite-reinforced glass ceramic (13%). There were significant differences (p<0.05) by dentist’s gender, race, years since graduation, practice type, region, practice busyness, hours worked/week, and location type. The top 3 choices for posterior crowns were all-zirconia (32%), PFM (31%), and lithium disilicate (21%). There were significant differences (p<0.05) by dentist’s gender, practice type, region, practice busyness, insurance coverage, hours worked/week, and location type. Conclusions Network dentists use a broad range of materials for single-unit crowns for anterior and posterior teeth, adopting newer materials into their practices as they become available. Material choices are significantly associated with dentist’s and practice’s characteristics. Clinical Significance Decisions for crown material may be influenced by factors unrelated to tooth and patient variables. Dentists should be cognizant of this when developing an evidence-based approach to selecting crown material. PMID:27693778

  17. Radiolucency below the crown of mandibular horizontal incompletely impacted third molars and acute inflammation in men with diabetes

    Directory of Open Access Journals (Sweden)

    Minoru Yamaoka

    2009-05-01

    Full Text Available Minoru Yamaoka, Yusuke Ono, Masahide Ishizuka, Kouichi Yasuda, Takashi Uematsu, Kiyofumi FurusawaOral and Maxillofacial Surgery, Matsumoto Dental University, Shiojiri, Nagano 399-0781, JapanAbstract: Although mandibular third molar has a high risk of infection extending any complications, the influence of diabetes on radiolucency and acute inflammation in pericoronitis remains unclear. The present study was to evaluate whether radiolucency below the crown is related to acute inflammation in mandibular horizontal incompletely impacted third molars and to review the records of 140 men more than 45 years with and without diabetes. The odds ratio of exhibiting acute inflammation was 3.38 (95% CI: 1.13–10.16, p < 0.05 and that of exhibiting severe acute inflammation was 15.38 (95% CI: 3.56–66.49, p < 0.0001, indicating an association of acute pericoronitis in diabetes. The frequency of radiolucency below the crown and below the root in diabetics was similar to that in nondiabetics. However, the odds ratio of exhibiting both radiolucency below the crown and acute inflammation under the diabetic condition was 4.85 (95% CI: 1.60–14.73, p < 0.01, whereas that of diabetics showing both radiolucency below the root and acute inflammation was 0.46 (95% CI: 0.06–3.74, p = 0.74. Radiolucency below the crown and acute inflammation were associated with diabetes, but that below root and acute inflammation were not associated with diabetes, indicating that the region below the crown carries susceptibility to acute pericoronitis, whereas the periodontium shows a protective effect against acute pericoronitis.Keywords: radiolucency, acute inflammation, mandible, third molar, diabetes, periodontium

  18. Modification of tolerance of oats to crown rust induced by chemical mutagens

    International Nuclear Information System (INIS)

    Simons, M.D.; Browning, J.A.; Frey, K.J.

    1983-01-01

    Seeds of crown rust (Puccinia coronata) susceptible cultivated oats (Avena sativa) were treated with the mutagenic chemical ethyl methanesulphonate (EMS), and pure lines derived from these treated seeds were tested in later generations for the relative amount of reduction in yield and seed weight caused by crown rust infection. In the absence of crown rust, the yield of most of the treated lines was greatly reduced. The overall means of the treated lines for both yield and seed weight response to infection were significantly lower than the control, but 10 lines significantly exceeded the control for yield response and 15 exceeded it for seed weight response. Recurrent EMS treatment of once-treated lines rated as tolerant resulted in groups of lines that were more tolerant, on the average, than groups of lines from recurrently treated lines rated as susceptible. A few of the recurrently treated individual lines derived from tolerant parents had a higher degree of tolerance than their parental lines. EMS treatment of diploid (A. strigosa) and tetraploid (A. abyssinica) oats resulted in groups of lines showing significant genetic variance for response to crown rust, indicating that treatment had induced real genetic change. A few diploid lines were a little more tolerant than their control, but none of the tetraploid lines showed any consistent improvement. (author)

  19. Suppression of crown and root rot of wheat by the rhizobacterium Paenibacillus polymyxa

    Directory of Open Access Journals (Sweden)

    Lamia LOUNACI

    2017-01-01

    Full Text Available A seedling bioassay was developed for screening a wheat root-associated rhizobacterial strain of Paenibacillus polymyxa for ability to suppress crown and root rot pathogens of wheat. The primary aim was to evaluate the ability of P. polymyxa to suppress Fusarium graminearum, F. culmorum, F. verticillioides and Microdochium nivale, the fungal pathogens responsible for Fusarium crown and root rot and head blight of wheat in Algeria. Bioassays conducted under controlled conditions indicated that seed treatments with P. polymyxa strain SGK2 significantly reduced disease symptoms caused by all four fungal pathogens. Plant growth promotion (increased shoot and root dry weights, however, depended on the pathogen tested. Our results indicate that seed treatments with a biocontrol agent could be an additional strategy for management of wheat crown and root rot pathogens.

  20. Lipophilization of dihydrocaffeic acid affects its antioxidative properties in fish‐oil‐enriched emulsions

    DEFF Research Database (Denmark)

    Sørensen, Ann-Dorit Moltke; Nielsen, Nina Skall; Yang, Zhiyong

    2012-01-01

    their efficacy opens up new possibilities for producing new and more efficient antioxidants for food systems. However, the results also show that optimization of the chain length for each type of phenolic compound may be necessary. Since these compounds may have a much higher efficacy against lipid oxidation...... a lower amount of antioxidant will be necessary to obtain the same effect. This would decrease the costs. In addition, the use of synthetic antioxidants, that might have toxic effect in vivo, can be avoided. The raw materials used for the lipophilized compounds are natural compounds, however the fate...

  1. Possible applications of crown-ethers to metal extraction using liquid membrane technology - a literature survey

    International Nuclear Information System (INIS)

    Dozol, M.

    1990-01-01

    Ether-crowns, discovered in 1967 by J.C. PEDERSEN, exhibit attractive complexive and extractive properties, enhanced in various fields, such as analytical chemistry, chemical synthesis, field of biology, or extractive chemistry. The investigations carried out on these macrocyclic compounds are continually increasing, as show in international literature. Among the focus of interest, the applications to metal extraction are extensively studied with crown compounds present in liquid phase or impregnated on supports (membranes or resins). The goal of this paper is to describe the application of crown-ethers to metal extraction, using liquid membrane processes. 69 refs

  2. Optimal Cluster Mill Pass Scheduling With an Accurate and Rapid New Strip Crown Model

    International Nuclear Information System (INIS)

    Malik, Arif S.; Grandhi, Ramana V.; Zipf, Mark E.

    2007-01-01

    Besides the requirement to roll coiled sheet at high levels of productivity, the optimal pass scheduling of cluster-type reversing cold mills presents the added challenge of assigning mill parameters that facilitate the best possible strip flatness. The pressures of intense global competition, and the requirements for increasingly thinner, higher quality specialty sheet products that are more difficult to roll, continue to force metal producers to commission innovative flatness-control technologies. This means that during the on-line computerized set-up of rolling mills, the mathematical model should not only determine the minimum total number of passes and maximum rolling speed, it should simultaneously optimize the pass-schedule so that desired flatness is assured, either by manual or automated means. In many cases today, however, on-line prediction of strip crown and corresponding flatness for the complex cluster-type rolling mills is typically addressed either by trial and error, by approximate deflection models for equivalent vertical roll-stacks, or by non-physical pattern recognition style models. The abundance of the aforementioned methods is largely due to the complexity of cluster-type mill configurations and the lack of deflection models with sufficient accuracy and speed for on-line use. Without adequate assignment of the pass-schedule set-up parameters, it may be difficult or impossible to achieve the required strip flatness. In this paper, we demonstrate optimization of cluster mill pass-schedules using a new accurate and rapid strip crown model. This pass-schedule optimization includes computations of the predicted strip thickness profile to validate mathematical constraints. In contrast to many of the existing methods for on-line prediction of strip crown and flatness on cluster mills, the demonstrated method requires minimal prior tuning and no extensive training with collected mill data. To rapidly and accurately solve the multi-contact problem

  3. Population genetics of the endangered Crowned Solitary Eagle (Buteogallus coronatus) in South America

    OpenAIRE

    Canal, David; Roques, Séverine; Negro, Juan J.; Sarasola, José Hernán

    2017-01-01

    The Crowned Solitary Eagle (Buteogallus coronatus) is one of the rarest and most severely threatened birds of prey in the Neotropical region. We studied levels of neutral genetic diversity, population structure, and the demographic history of the species using 55 contemporary samples covering a large fraction of the species range, which were genotyped at 17 microsatellite loci. Our results indicated genetic homogeneity across the sampled regions, which may be explained by a high dispersal cap...

  4. The use of definitive implant abutments for the fabrication of provisional crowns: a case series.

    Science.gov (United States)

    Bilhan, Hakan; Geckili, Onur; Mumcu, Emre

    2011-10-01

    The anterior region is a challenge for most clinicians to achieve optimal esthetics with dental implants. The provisional crown is a key factor in the success of obtaining pink esthetics around restorations with single implants, by soft tissue and inter-proximal papilla shaping. Provisional abutments bring additional costs and make the treatment more expensive. Since one of the aims of the clinician is to reduce costs and find more economic ways to raise patient satisfaction, this paper describes a practical method for chair-side fabrication of non-occlusal loaded provisional crowns used by the authors for several years successfully. Twenty two patients (9 males, 13 females; mean age, 36,72 years) with one missing anterior tooth were treated by using the presented method. Metal definitive abutments instead of provisional abutments were used and provisional crowns were fabricated on the definitive abutments for all of the patients. The marginal fit was finished on a laboratory analogue and temporarily cemented to the abutments. The marginal adaptation of the crowns was evaluated radiographically. The patients were all satisfied with the final appearance and no complications occurred until the implants were loaded with permanent restorations. The use of the definitive abutments for provisional crowns instead of provisional abutments reduces the costs and the same results can be obtained.

  5. The Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement

    Directory of Open Access Journals (Sweden)

    Jalil Ganbarzadeh

    2013-01-01

    Full Text Available Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI, 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughened with sandblast (50-µm aluminum oxide and in the second group, 10 abutments were roughened with diamond bur. The third group had no surface treatment. Then, thirty implant fixture analogs (ITI were placed in the center of acrylic cylinders. After that a solid abutment was tightened on the each fixture analog with 35 N/cm force. Thirty base metal crowns were made on the 4 mm ITI abutment analogs using plastic coping. The prepared copings were cemented on the abutments by TempBond temporary cement and finally, crowns were pulled from the abutment in a universal test machine at a cross speed of 0.5cm/min. Results: The mean tensile strength in sandblasted, bur treated, and control group were 64.38±8, 91.37±7.19, and 58.61±1.93, respectively. Bur treated group showed higher tensile strength in comparison with two other groups. Conclusion: Surface modification of implant abutment by diamond bur may be an effective method to increase retention of crown when TempBond is used.

  6. Chemical Characterization of Lipophilic Constituents in the Skin of Migratory Adult Sea Lamprey from the Great Lakes Region.

    Directory of Open Access Journals (Sweden)

    Amila A Dissanayake

    Full Text Available The sea lamprey (Petromzons marinus is an invasive ectoparasite of large-bodied fishes that adversely affects the fishing industry and ecology of the Laurentian Great Lakes. Lipid content in the whole sea lamprey and muscles, liver and kidney of metamorphosing larval stages has been reported. Similarly, the fatty acid profile of the rope tissues of sexually-mature male sea lampreys has also been reported. The average body weight of a sub-adult migratory sea lamprey is 250 g, which includes 14.4% skin (36 g. Our preliminary extraction data of an adult sea lamprey skin revealed that it contained approximately 8.5% of lipophilic compounds. Lamprey skin is home to a naturally aversive compound (an alarm cue that is being developed into a repellent for use in pest management. As part of an ongoing investigation to identify the chemical structure of the sea lamprey alarm cue, we extracted the skin with water and methanol, respectively. The methanolic extract (1.55% contained exclusively lipophilic compounds and did not include the alarm cue. We chemically characterized all compounds present in the methanolic extract as cholesterol esters (CE, tri- and di-glycerides (TG and DG, cholesterol, free fatty acids (FFA and minor amounts of plasticizers. The free fatty acids fraction was composed of saturated (41.8%, monounsaturated (40.7% and polyunsaturated (17.4% fatty acids, respectively. The plasticizers characterized were phthalate and benzoate and found to be 0.95 mg and 2.54 mg, respectively, per adult sea lamprey skin. This is the first report of the chemical characterization of all the lipophilic constituents in the skin of sub-adult migratory sea lamprey. The CEs isolated and characterized from sea lamprey skin are also for the first time.

  7. Crown characteristics of juvenile loblolly pine 6 years after application of thinning and fertilization

    Science.gov (United States)

    Shufang Yu; Jim L. Chambers; Zhenmin Tang; James P. Barnett

    2003-01-01

    Total foliage dry mass and leaf area at the canopy hierarchical level of needle, shoot, branch and crown were measured in 48 trees harvested from a 14-year-old loblolly pine (Pinus taeda L.) plantation, six growing seasons after thinning and fertilization treatments. In the unthinned treatment, upper crown needles were heavier and had more leaf area...

  8. Effects of photographic distance on tree crown atributes calculated using urbancrowns image analysis software

    Science.gov (United States)

    Mason F. Patterson; P. Eric Wiseman; Matthew F. Winn; Sang-mook Lee; Philip A. Araman

    2011-01-01

    UrbanCrowns is a software program developed by the USDA Forest Service that computes crown attributes using a side-view digital photograph and a few basic field measurements. From an operational standpoint, it is not known how well the software performs under varying photographic conditions for trees of diverse size, which could impact measurement reproducibility and...

  9. Midday Depression vs. Midday Peak in Diurnal Light Interception: Contrasting Patterns at Crown and Leaf Scales in a Tropical Evergreen Tree

    Directory of Open Access Journals (Sweden)

    Agustina Ventre-Lespiaucq

    2018-05-01

    Full Text Available Crown architecture usually is heterogeneous as a result of foraging in spatially and temporally heterogeneous light environments. Ecologists are only beginning to identify the importance of temporal heterogeneity for light acquisition in plants, especially at the diurnal scale. Crown architectural heterogeneity often leads to a diurnal variation in light interception. However, maximizing light interception during midday may not be an optimal strategy in environments with excess light. Instead, long-lived plants are expected to show crown architectures and leaf positions that meet the contrasting needs of light interception and avoidance of excess light on a diurnal basis. We expected a midday depression in the diurnal course of light interception both at the whole-crown and leaf scales, as a strategy to avoid the interception of excessive irradiance. We tested this hypothesis in a population of guava trees (Psidium guajava L. growing in an open tropical grassland. We quantified three crown architectural traits: intra-individual heterogeneity in foliage clumping, crown openness, and leaf position angles. We estimated the diurnal course of light interception at the crown scale using hemispheric photographs, and at the leaf scale using the cosine of solar incidence. Crowns showed a midday depression in light interception, while leaves showed a midday peak. These contrasting patterns were related to architectural traits. At the crown scale, the midday depression of light interception was linked to a greater crown openness and foliage clumping in crown tops than in the lateral parts of the crown. At the leaf scale, an average inclination angle of 45° led to the midday peak in light interception, but with a huge among-leaf variation in position angles. The mismatch in diurnal course of light interception at crown and leaf scales can indicate that different processes are being optimized at each scale. These findings suggest that the diurnal course of

  10. Preliminary analysis of relation between natural and anthropic elements in the calanco area of Podere Paiccia (Southern Tuscany - Italy): crowns of mudflow vs. erosion control practices (graticciate) during the period 1989-2015.

    Science.gov (United States)

    Colica, Antonella; Martinelli, Lorenzo

    2016-04-01

    The study area Podere Paiccia, which is characterized by four calanchi, extends over a surface of 155,000 square meters, on N-NNW slopes, from 435 to 513m, with an average slope of 25° and it develops on Pliocene marine bedrocks. The calanchi represent an important morphology in southern Tuscany and also in Pliocene and Plio-Pleistocene bedrock in nearby areas of piedmont zones of Apennines. During the 1989 the "Consorzio di Bonifica della Val d'Orcia" introduced erosion control practices named graticciate (fences) along three of the four calanchi. They consisted of chestnut stakes (about 1 m long), fixed in the ground, connected by smaller transverse stakes and placed perpendicularly to the slopes, at 7-10 meters intervals, extending laterally for about 10 meters. These calanchi are formed by gullies, rills, crowns and mudflows. The crowns, one of the more dynamic erosional forms, are generally arch-shaped (40-50 cm in height, vary in width, gradient 54°÷90°). The four calanchi, named 1-2-3-4, were divided into three zones of equal size: high, medium and low. The analysis conducted by photo shoots and field measurements, during the years 1989-1992-1996-2002-2005-2015, aim to discover the relation between crowns and graticciate. In 1989, 1 did not present graticciate, 2 had graticciate in all 3 zones (28), 3 and 4 had graticciate (24 and 22 respectively) but only in the medium and high zones. The crowns (57 in 1, 58 in 2, 78 in 3 and 56 in 4) rise towards the ridges. In case during the ascend crowns meet the graticciate, these last are deformed and then destroyed (periods: 1989÷1992, 1992÷1996, 1996÷2002, 2002÷2005, 2005÷2015, graticciate destroyed along the 2, 3, 4,% mean values: 51, 87, 100 - 26, 46, 72, 90 costant value from 2005 - 57, 75 costant value 1992÷2002, 78,100). Until total destruction, graticciate limit the number of crowns in the high zones. Along 2, 3 and 4 the number of crowns is greater in the medium zones (mean values of the ratios

  11. Percutaneous penetration enhancement effect of essential oil of mint (Mentha haplocalyx Briq. on Chinese herbal components with different lipophilicity

    Directory of Open Access Journals (Sweden)

    Jingyan Wang

    2014-10-01

    Conclusions: Mint oil at proper concentration could effectively facilitate percutaneous penetration of both lipophilic and hydrophilic drugs, and exhibit higher efficiency for moderate hydrophilic drugs. Mechanisms of penetration enhancement by mint oil could be explained with saturation solubility, SC/vehicle partition coefficient and the secondary structure change of SC.

  12. The computation of lipophilicities of ⁶⁴Cu PET systems based on a novel approach for fluctuating charges.

    Science.gov (United States)

    Comba, Peter; Martin, Bodo; Sanyal, Avik; Stephan, Holger

    2013-08-21

    A QSPR scheme for the computation of lipophilicities of ⁶⁴Cu complexes was developed with a training set of 24 tetraazamacrocylic and bispidine-based Cu(II) compounds and their experimentally available 1-octanol-water distribution coefficients. A minimum number of physically meaningful parameters were used in the scheme, and these are primarily based on data available from molecular mechanics calculations, using an established force field for Cu(II) complexes and a recently developed scheme for the calculation of fluctuating atomic charges. The developed model was also applied to an independent validation set and was found to accurately predict distribution coefficients of potential ⁶⁴Cu PET (positron emission tomography) systems. A possible next step would be the development of a QSAR-based biodistribution model to track the uptake of imaging agents in different organs and tissues of the body. It is expected that such simple, empirical models of lipophilicity and biodistribution will be very useful in the design and virtual screening of positron emission tomography (PET) imaging agents.

  13. Assessment of oral hygiene and periodontal health around posterior primary molars after their restoration with various crown types.

    Science.gov (United States)

    Beldüz Kara, Nihal; Yilmaz, Yucel

    2014-07-01

    To compare the time-dependent changes in oral hygiene and periodontal health after restoring primary posterior molars with a traditional stainless steel crown (SSC) or an aesthetic crown using various measures of periodontal health and oral hygiene. This investigation was a randomized, non-blinded prospective controlled clinical trial in which 264 crowns of different types were fitted onto the first and/or second primary molars of 76 children. The oral hygiene and the gingival health of the restored teeth and the antagonistic teeth were evaluated clinically and radiographically at 3- and 6-month intervals for 18 months after fitting the crowns. The periodontal health of the control teeth was better than that of the remaining 215 restored teeth. The oral hygiene, as measured by the simplified oral hygiene index, and gingival health, as measured by the gingival index and the volume of gingival crevicular fluid, of the restored teeth, irrespective of crown type, progressively increased during the 18-month study period. Oral hygiene and gingival health around a restored primary tooth deteriorate with time. Our results suggest that SSC, an open-faced SSC, or a NuSmile(®) pediatric crown should be the preferred crown type for restoring posterior primary teeth. © 2013 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. A study of solvent extraction of uranium and thorium with a crown either carboxylic acid

    International Nuclear Information System (INIS)

    Du Hongshan

    1995-03-01

    The solvent extraction of uranium and thorium with a new type of extractant sym-dibenzo-16-crown-5-oxyacetic acid in chloroform has been studied. The extraction efficiencies for both elements depend strongly on pH. At pH 3.5, UO 2 2+ is not extractable, whereas Th 4+ is extracted with greater than 98% efficiency. The dependence of the distribution ratios of UO 2 2+ and Th 4+ on the concentration of sym-dibenzo-16-crown-5-oxyacetic acid are linear and the slopes are 1 and 2 respectively. The results suggest that uranium and thorium appear to form a 1 : 1 and 1 : 2 extraction complex with ligand. A new method for separating U and Th is established, and U and Th with high purity can be obtained. This method have important application to analytical chemistry and nuclear industry. (8 refs., 3 figs.)

  15. Esthetic rehabilitation of complicated crown fractures utilizing rapid orthodontic extrusion and two different restoration modalities.

    Science.gov (United States)

    Milardovic Ortolan, Sladana; Strujic, Mihovil; Aurer, Andrej; Viskic, Josko; Bergman, Lana; Mehulic, Ketij

    2012-01-01

    This case report describes the management of a crown-root fractured maxillary right central incisor and a crown fractured maxillary left central incisor using two different techniques. A complex procedure was designed to manage this case including orthodontic extrusion to move the fracture line above the alveolar bone and surgical recontouring of the altered gingival margin. Finally, the right incisor was restored prosthodontically. Prosthetic treatment was based on performing a post and core, and all-ceramic crown on the extruded tooth. The left, less-damaged incisor was restored directly using composite resin. The treatment resulted in good esthetics and secured periodontal health. This case report demonstrates that a multidisciplinary treatment approach is a reliable and predictable option to save a tooth. How to cite this article: Ortolan SM, Strujic M, Aurer A, Viskic J, Bergman L, Mehulic K. Esthetic Rehabilitation of Complicated Crown Fractures Utilizing Rapid Orthodontic Extrusion and Two Different Restoration Modalities. Int J Clin Pediatr Dent 2012;5(1):64-67.

  16. Study on the Preparation and Antileukemic Activity of New Lipophilic 1-β-D-arabinofuranosylcytosine Derivatives

    Science.gov (United States)

    Chu, Yanyan; Tian, Zhenhua; Hou, Yingwei; Li, Wenbao

    2018-04-01

    Cytarabine (1-β-D-arabinofuranosylcytosine, Ara-C), isolated from a Caribbean sponge species Tethyacrypta, is the first antitumor drug from a marine resource. In 1980, the US Food and Drug Administration approved this drug for the treatment of different types of leukemia. This drug has a short plasma half-life, low stability, limited bioavailability, and severe side effects. To improve stability and bioavailability, we synthesized nine novel derivatives by blocking the cytarabine metabolic sites and improving lipophilicity. The cLogP values of the newly synthesized compounds were calculated. All the synthesized compounds were more lipophilic than cytarabine, resulting in membrane permeability and bioavailability improvement. The antitumor activities against leukemia cell line HL-60 were evaluated by using the MTT assay. The bioassay results revealed that the IC50 values of compounds 5, 8 and 9 were 0.080, 0.090 and 0.057 μmol L-1, respectively, which was similar with that of cytarabine (0.056 μmol L-1). In comparison, compound 4 with a phosphate group at O5' was inactive. Because phosphoester bonds are easily hydrolyzed by alkaline phosphatase and are commonly used in producing prodrug strategies, compound 4 might also be metabolized in vivo and generate compound 3 or even cytarabine through a multi-step reaction. Thus, compound 4 might be a promising compound to be developed as a prodrug.

  17. Magnetic hydrophilic-lipophilic balance sorbent for efficient extraction of chemical warfare agents from water samples.

    Science.gov (United States)

    Singh, Varoon; Purohit, Ajay Kumar; Chinthakindi, Sridhar; Goud D, Raghavender; Tak, Vijay; Pardasani, Deepak; Shrivastava, Anchal Roy; Dubey, Devendra Kumar

    2016-02-19

    Magnetic hydrophilic-lipophilic balance (MHLB) hybrid resin was prepared by precipitation polymerization using N-vinylpyrrolidone (PVP) and divinylbenzene (DVB) as monomers and Fe2O3 nanoparticles as magnetic material. These resins were successfully applied for the extraction of chemical warfare agents (CWAs) and their markers from water samples through magnetic dispersive solid-phase extraction (MDSPE). By varying the ratios of monomers, resin with desired hydrophilic-lipophilic balance was prepared for the extraction of CWAs and related esters of varying polarities. Amongst different composites Fe2O3 nanoparticles coated with 10% PVP+90% DVB exhibited the best recoveries varying between 70.32 and 97.67%. Parameters affecting the extraction efficiencies, such as extraction time, desorption time, nature and volume of desorption solvent, amount of extraction sorbent and the effect of salts on extraction were investigated. Under the optimized conditions, linearity was obtained in the range of 0.5-500 ng mL(-1) with correlation ranging from 0.9911-0.9980. Limits of detection and limits of quantification were 0.5-1.0 and 3.0-5.0 ng mL(-1) respectively with RSDs varying from 4.88-11.32% for markers of CWAs. Finally, the developed MDSPE method was employed for extraction of analytes from water samples of various sources and the OPCW proficiency test samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Antitumor potential of crown ethers: structure-activity relationships, cell cycle disturbances, and cell death studies of a series of ionophores.

    Science.gov (United States)

    Marjanović, Marko; Kralj, Marijeta; Supek, Fran; Frkanec, Leo; Piantanida, Ivo; Smuc, Tomislav; Tusek-Bozić, Ljerka

    2007-03-08

    The present paper demonstrates the antiproliferative ability and structure-activity relationships (SAR) of 14 crown and aza-crown ether analogues on five tumor-cell types. The most active compounds were di-tert-butyldicyclohexano-18-crown-6 (3), which exhibited cytotoxicity in the submicromolar range, and di-tert-butyldibenzo-18-crown-6 (5) (IC50 values of approximately 2 microM). Also, 3 and 5 induced marked influence on the cell cycle phase distribution--strong G1 arrest, followed by the induction of apoptosis. A computational SAR modeling effort offers insight into possible mechanisms of crown ether biological activity, presumably involving penetration into cell membranes, and points out structural features of molecules important for this activity. The results reveal that crown ethers possess marked tumor-cell growth inhibitory activity, the extent of which depends on the characteristics of the hydrophilic macrocylic cavity and the surrounding hydrophobic ring. Our work supports the hypothesis that crown ether compounds inhibit tumor-cell growth by disrupting potassium ion homeostasis, which in turn leads to cell cycle perturbations and apoptosis.

  19. Evaluation of the fracture resistance of computer-aided design/computer-aided manufacturing monolithic crowns prepared in different cement thicknesses.

    Science.gov (United States)

    Sagsoz, N Polat; Yanıkoglu, N

    2018-04-01

    The purpose of this study was to evaluate the fracture resistance of monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) crowns that are prepared with different cement thickness. For this investigation, a human maxillary premolar tooth was selected. Master model preparation was performed with a demand bur under water spray. Master die was taken to fabricate 105 epoxy resin replicas. The crowns were milled using a CEREC 4 CAD/CAM system (Software Version, 4.2.0.57192). CAD/CAM crowns were made using resin nanoceramic, feldspathic glass ceramic, lithium disilicate, and leucite-reinforced ceramics. Each group was subdivided into three groups in accordance with three different cement thicknesses (30, 90, and 150 μm). Crowns milled out. Then RelyX ™ U200 was used as a luting agent to bond the crowns to the prepared samples. After one hour cementations, the specimens were stored in water bath at 37°C for 1 week before testing. Seven unprepared and unrestored teeth were kept and tested as a control group. A universal test machine was used to assume the fracture resistance of all specimens. The compressive load (N) that caused fracture was recorded for each specimen. Fracture resistance data were statistically analyzed by one-way ANOVA and two-factor interaction modeling test (α = 0.001). There are statistically significant differences between fracture resistances of CAD/CAM monolithic crown materials (P cement thickness is not statistically significant for fracture resistance of CAD/CAM monolithic crowns (P > 0.001). CAD/CAM monolithic crown materials affected fracture resistance. Cement thickness (30, 90, and 150 μm) was not effective on fracture resistance of CAD/CAM monolithic crowns.

  20. A novel technique to check the occlusion during the placement of stainless steel crowns under general anesthesia

    Directory of Open Access Journals (Sweden)

    Mohiddin Dimashkieh

    2015-01-01

    Full Text Available Stainless steel crowns are the restoration of choice for the treatment of badly decayed posterior teeth under general anesthesia. The evaluation of occlusion after the placement of these crowns, however, remains a difficult task. This paper outlines a technique to evaluate the occlusion of stainless steel crowns placed under general anesthesia using a specially designed tray and a fast setting polyvinyl siloxane bite registration material (Regisil® PB™, Dentsply, Surrey UK.