WorldWideScience

Sample records for higher detection rates

  1. 3D versus 2D Systematic Transrectal Ultrasound-Guided Prostate Biopsy: Higher Cancer Detection Rate in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Alexandre Peltier

    2013-01-01

    Full Text Available Objectives. To compare prostate cancer detection rates of extended 2D versus 3D biopsies and to further assess the clinical impact of this method in day-to-day practice. Methods. We analyzed the data of a cohort of 220 consecutive patients with no prior history of prostate cancer who underwent an initial prostate biopsy in daily practice due to an abnormal PSA and/or DRE using, respectively, the classical 2D and the new 3D systems. All the biopsies were done by a single experienced operator using the same standardized protocol. Results. There was no significant difference in terms of age, total PSA, or prostate volume between the two groups. However, cancer detection rate was significantly higher using the 3D versus the 2D system, 50% versus 34% (P<0.05. There was no statistically significant difference while comparing the 2 groups in term of nonsignificant cancer detection. Conclusion. There is reasonable evidence demonstrating the superiority of the 3D-guided biopsies in detecting prostate cancers that would have been missed using the 2D extended protocol.

  2. CpG Oligonucleotide and Interleukin 2 stimulation enables higher cytogenetic abnormality detection rates than 12-o-tetradecanolyphorbol-13-acetate in Asian patients with B-cell chronic lymphocytic leukemia (B-CLL).

    Science.gov (United States)

    Liaw, Fiona Pui San; Lau, Lai Ching; Lim, Alvin Soon Tiong; Lim, Tse Hui; Lee, Geok Yee; Tien, Sim Leng

    2014-12-01

    The present study was designed to compare abnormality detection rates using DSP30 + IL2 and 12-O-Tetradecanoylphorbol-13-acetate (TPA) in Asian patients with B-CLL. Hematological specimens from 47 patients (29 newly diagnosed, 18 relapsed) were established as 72 h-DSP30 + IL2 and TPA cultures. Standard methods were employed to identify clonal aberrations by conventional cytogenetics (CC). The B-CLL fluorescence in situ hybridization (FISH) panel comprised ATM, CEP12, D13S25, and TP53 probes. DSP30 + IL2 cultures had a higher chromosomal abnormality detection rate (67 %) compared to TPA (44 %, p 0.05). Thirteen cases with abnormalities were found exclusively in DSP30 + IL2 cultures compared to one found solely in TPA cultures. DSP30 + IL2 cultures were comparable to the FISH panel in detecting 11q-, +12 and 17p- but not 13q-. It also has a predilection for 11q- bearing leukemic cells compared to TPA. FISH had a higher abnormality detection rate (84.1 %) compared to CC (66.0 %) with borderline significance (p = 0.051), albeit limited by its coverage. In conclusion, DSP30 + IL2 showed a higher abnormality detection rate. However, FISH is indispensable to circumvent low mitotic indices and detect subtle abnormalities.

  3. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    Directory of Open Access Journals (Sweden)

    Qing-Hui WANG

    2014-02-01

    Full Text Available This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or concentration, the proposed detection system with lower cost and higher accuracy can be applied in the occasion which needs simultaneous monitoring of gas concentration and flow rate.

  4. Heart rate detection from an electronic weighing scale

    International Nuclear Information System (INIS)

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2008-01-01

    We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V −1 N −1 to 1670 nV V −1 N −1 . The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland–Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was ±21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate

  5. Rate based failure detection

    Science.gov (United States)

    Johnson, Brett Emery Trabun; Gamage, Thoshitha Thanushka; Bakken, David Edward

    2018-01-02

    This disclosure describes, in part, a system management component and failure detection component for use in a power grid data network to identify anomalies within the network and systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription. The failure detection component may identify an anomaly within the network and a source of the anomaly. Based on the identified anomaly, data rates and or data paths may be adjusted in real-time to ensure that the power grid data network does not become overloaded and/or fail.

  6. Application of a conversion factor to estimate the adenoma detection rate from the polyp detection rate.

    LENUS (Irish Health Repository)

    Francis, Dawn L

    2011-03-01

    The adenoma detection rate (ADR) is a quality benchmark for colonoscopy. Many practices find it difficult to determine the ADR because it requires a combination of endoscopic and histologic findings. It may be possible to apply a conversion factor to estimate the ADR from the polyp detection rate (PDR).

  7. Detectability and detection rate of acute cerebral hemisphere infarcts on CT and diffusion-weighted MRI

    International Nuclear Information System (INIS)

    Urbach, H.; Flacke, S.; Keller, E.; Textor, J.; Berlis, A.; Reul, J.; Schild, H.H.; Hartmann, A.; Solymosi, L.

    2000-01-01

    Our purpose was to compare the detectability and detection rate of acute ischaemic cerebral hemisphere infarcts on CT and diffusion-weighted MRI (DWI). We investigated 32 consecutive patients with acute hemisphere stroke with unenhanced CT and DWI within 6 h of stroke onset. The interval between CT and DWI ranged from 15 to 180 min (mean 60 min). Infarct detectability on CT and DWI was determined by comparing the initial CT, DWI and later reference images in a consensus reading of five independent examiners. The ''true'' detection rate was assessed by analysing all single readings. Two patients had intracerebral haematomas on DWI and CT and were excluded. There were 27 patients with ischaemic infarcts; all were visible on DWI and proven by follow-up. DWI was negative in three patients without a final diagnosis of infarct (100 % sensitivity, 100 % specificity, χ 2 = 30, P 2 = 1.48, P = 0.224). With regard to the single readings (30 examinations x 5 examiners = 150 readings), 63 CT readings were true positive and 72 false negative (sensitivity 47 %, specificity 86 %, χ 2 = 2.88, P = 0.089). Of the DWI readings 128 were true positive and 7 false negative (sensitivity 95 %, specificity 87 %, χ 2 = 70.67, P < 0.0001). Interobserver agreement was substantial for CT (χ= 0.72, 95 % confidence interval, 0.6-0.84) and DWI (χ= 0.82, 95 % confidence interval, 0.46-1). Taken together, detectability and detection rate of acute (< 6 h) hemisphere infarcts are significantly higher with DWI than with CT. (orig.)

  8. The detection of higher-order acoustic transitions is reflected in the N1 ERP.

    Science.gov (United States)

    Weise, Annekathrin; Schröger, Erich; Horváth, János

    2018-01-30

    The auditory system features various types of dedicated change detectors enabling the rapid parsing of auditory stimulation into distinct events. The activity of such detectors is reflected by the N1 ERP. Interestingly, certain acoustic transitions show an asymmetric N1 elicitation pattern: whereas first-order transitions (e.g., a change from a segment of constant frequency to a frequency glide [c-to-g change]) elicit N1, higher-order transitions (e.g., glide-to-constant [g-to-c] changes) do not. Consensus attributes this asymmetry to the absence of any available sensory mechanism that is able to rapidly detect higher-order changes. In contrast, our study provides compelling evidence for such a mechanism. We collected electrophysiological and behavioral data in a transient-detection paradigm. In each condition, a random (50%-50%) sequence of two types of tones occurred, which did or did not contain a transition (e.g., c-to-g and constant stimuli or g-to-c and glide tones). Additionally, the rate of pitch change of the glide varied (i.e., 10 vs. 40 semitones per second) in order to increase the number of responding neural assemblies. The rate manipulation modulated transient ERPs and behavioral detection performance for g-to-c transitions much stronger than for c-to-g transitions. The topographic and tomographic analyses suggest that the N1 response to c-to-g and also to g-to-c transitions emerged from the superior temporal gyrus. This strongly supports a sensory mechanism that allows the fast detection of higher-order changes. © 2018 Society for Psychophysiological Research.

  9. Water Exchange Produces Significantly Higher Adenoma Detection Rate Than Water Immersion: Pooled Data From 2 Multisite Randomized Controlled Trials.

    Science.gov (United States)

    Leung, Felix W; Koo, Malcolm; Cadoni, Sergio; Falt, Premysl; Hsieh, Yu-Hsi; Amato, Arnaldo; Erriu, Matteo; Fojtik, Petr; Gallittu, Paolo; Hu, Chi-Tan; Leung, Joseph W; Liggi, Mauro; Paggi, Silvia; Radaelli, Franco; Rondonotti, Emanuele; Smajstrla, Vit; Tseng, Chih-Wei; Urban, Ondrej

    2018-03-02

    To test the hypothesis that water exchange (WE) significantly increases adenoma detection rates (ADR) compared with water immersion (WI). Low ADR was linked to increased risk for interval colorectal cancers and related deaths. Two recent randomized controlled trials of head-to-head comparison of WE, WI, and traditional air insufflation (AI) each showed that WE achieved significantly higher ADR than AI, but not WI. The data were pooled from these 2 studies to test the above hypothesis. Two trials (5 sites, 14 colonoscopists) that randomized 1875 patients 1:1:1 to AI, WI, or WE were pooled and analyzed with ADR as the primary outcome. The ADR of AI (39.5%) and WI (42.4%) were comparable, significantly lower than that of WE (49.6%) (vs. AI P=0.001; vs. WI P=0.033). WE insertion time was 3 minutes longer than that of AI (Prate (vs. AI) of the >10 mm advanced adenomas. Right colon combined advanced and sessile serrated ADR of AI (3.4%) and WI (5%) were comparable and were significantly lower than that of WE (8.5%) (vs. AI P<0.001; vs. WI P=0.039). Compared with AI and WI, the superior ADR of WE offsets the drawback of a significantly longer insertion time. For quality improvement focused on increasing adenoma detection, WE is preferred over WI. The hypothesis that WE could lower the risk of interval colorectal cancers and related deaths should be tested.

  10. Relationship of detection rate of PET cancer screening examinees and risk factors. Analysis of background of examinees

    International Nuclear Information System (INIS)

    Shibata, Koji; Uno, Kimiichi; Arai, Masami; Matsuura, Masaaki; Yoshida, Teruhiko; Momose, Toshimitsu; Ohtomo, Kuni

    2011-01-01

    Positron emission tomography (PET) cancer screening is performed widely in Japan as opportunistic screening, but no study has focused on the correlation with various cancer risk factors and the seeking bias of examinees and cancer detection rate. Analyzing our large series of PET cancer screening data, correlations with cancer detection rates according to general cancer risk factors and PET detection survey were reviewed, and the selection bias of the medical examinees was determined. 19189 examinees who underwent PET cancer screening were enrolled. Using logistic-regression analysis, we analyzed correlations between smoking history/drinking history/cancer family history and detection rates of thyroid cancer/breast cancer/colorectal cancer/lung cancer, which are the main malignancies detected in PET cancer screening. In addition, we evaluated seeking bias of examinees, analyzing correlations between the presence of cancer risk factors and prior screening checkups at other institutions to our PET cancer screening using a matched case-control study. Cancer detection rates by FDG-PET were 1.17% (224/19189), being much higher than those of standard cancer mass screenings. In males, statistically significant correlations were seen between lung cancer and smoking, and between prostate cancer and a family history of prostate cancer, but not between the detection rates of three other types of cancer (thyroid cancer/lung cancer/colorectal cancer) and other cancer risk factors. In females, detection rates of four types of cancer (thyroid cancer/lung cancer/colorectal cancer/breast cancer) were significantly higher in the examinees without cancer risks, and subgroup analysis according to types of cancer did not indicate significant correlations either. The matched case-control study evaluating seeking bias indicated that a significant proportion of the examinees with cancer risks had undergone prior cancer screening at other institutions. Our study indicated that there was

  11. Arduino-based noise robust online heart-rate detection.

    Science.gov (United States)

    Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda

    2017-04-01

    This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.

  12. Higher-Order Cyclostationarity Detection for Spectrum Sensing

    Directory of Open Access Journals (Sweden)

    Julien Renard

    2010-01-01

    Full Text Available Recent years have shown a growing interest in the concept of Cognitive Radios (CRs, able to access portions of the electromagnetic spectrum in an opportunistic operating way. Such systems require efficient detectors able to work in low Signal-to-Noise Ratio (SNR environments, with little or no information about the signals they are trying to detect. Energy detectors are widely used to perform such blind detection tasks, but quickly reach the so-called SNR wall below which detection becomes impossible Tandra (2005. Cyclostationarity detectors are an interesting alternative to energy detectors, as they exploit hidden periodicities present in man-made signals, but absent in noise. Such detectors use quadratic transformations of the signals to extract the hidden sine-waves. While most of the literature focuses on the second-order transformations of the signals, we investigate the potential of higher-order transformations of the signals. Using the theory of Higher-Order Cyclostationarity (HOCS, we derive a fourth-order detector that performs similarly to the second-order ones to detect linearly modulated signals, at SNR around 0 dB, which may be used if the signals of interest do not exhibit second-order cyclostationarity. More generally this paper reviews the relevant aspects of the cyclostationary and HOCS theory, and shows their potential for spectrum sensing.

  13. Detection of sentinel lymph node in breast cancer and malignant melanoma - Influence of some factors on detection success rate

    International Nuclear Information System (INIS)

    Krafta, O.; Safarcika, K.; Stepien, A.

    2004-01-01

    missed in 31 patients (the success rate of dye 77.9 %). Detection rate with three radiopharmaceuticals was similar in both groups of patients. The higher number of detected sentinel lymph nodes per patient was using NANOCOLL. Our findings suggest that simultaneous use of all three methods - scintigraphy, isosulfan blue dye, and gamma probe should be employed for the detection of sentinel lymph nodes. (author)

  14. Direct inference of SNP heterozygosity rates and resolution of LOH detection.

    Directory of Open Access Journals (Sweden)

    Xiaohong Li

    2007-11-01

    Full Text Available Single nucleotide polymorphisms (SNPs have been increasingly utilized to investigate somatic genetic abnormalities in premalignancy and cancer. LOH is a common alteration observed during cancer development, and SNP assays have been used to identify LOH at specific chromosomal regions. The design of such studies requires consideration of the resolution for detecting LOH throughout the genome and identification of the number and location of SNPs required to detect genetic alterations in specific genomic regions. Our study evaluated SNP distribution patterns and used probability models, Monte Carlo simulation, and real human subject genotype data to investigate the relationships between the number of SNPs, SNP HET rates, and the sensitivity (resolution for detecting LOH. We report that variances of SNP heterozygosity rate in dbSNP are high for a large proportion of SNPs. Two statistical methods proposed for directly inferring SNP heterozygosity rates require much smaller sample sizes (intermediate sizes and are feasible for practical use in SNP selection or verification. Using HapMap data, we showed that a region of LOH greater than 200 kb can be reliably detected, with losses smaller than 50 kb having a substantially lower detection probability when using all SNPs currently in the HapMap database. Higher densities of SNPs may exist in certain local chromosomal regions that provide some opportunities for reliably detecting LOH of segment sizes smaller than 50 kb. These results suggest that the interpretation of the results from genome-wide scans for LOH using commercial arrays need to consider the relationships among inter-SNP distance, detection probability, and sample size for a specific study. New experimental designs for LOH studies would also benefit from considering the power of detection and sample sizes required to accomplish the proposed aims.

  15. Effect of recall rate on earlier screen detection of breast cancers based on the Dutch performance indicators.

    NARCIS (Netherlands)

    Otten, J.D.M.; Karssemeijer, N.; Hendriks, J.H.C.L.; Groenewoud, J.H.; Fracheboud, J.; Verbeek, A.L.M.; Koning, H.J. de; Holland, R.

    2005-01-01

    BACKGROUND: The recall rate (i.e., the rate at which mammographically screened women are recalled for additional assessment) in the Dutch breast screening program (0.89% in 2000 for subsequent examinations) is the lowest worldwide, with possible consequences including higher rates of late-detected

  16. Leak rate models and leak detection

    International Nuclear Information System (INIS)

    1992-01-01

    Leak detection may be carried out by a number of detection systems, but selection of the systems must be carefully adapted to the fluid state and the location of the leak in the reactor coolant system. Computer programs for the calculation of leak rates contain different models to take into account the fluid state before its entrance into the crack, and they have to be verified by experiments; agreement between experiments and calculations is generally not satisfactory for very small leak rates resulting from narrow cracks or from a closing bending moment

  17. DOUBLE COMPACT OBJECTS. III. GRAVITATIONAL-WAVE DETECTION RATES

    Energy Technology Data Exchange (ETDEWEB)

    Dominik, Michal; Belczynski, Krzysztof; Bulik, Tomasz [Astronomical Observatory, University of Warsaw, Al. Ujazdowskie 4, 00-478 Warsaw (Poland); Berti, Emanuele [Department of Physics and Astronomy, The University of Mississippi, University, MS 38677 (United States); O’Shaughnessy, Richard [Center for Gravitation, Cosmology, and Astrophysics, University of Wisconsin-Milwaukee, Milwaukee, WI (United States); Mandel, Ilya [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Fryer, Christopher [CCS-2, MSD409, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Holz, Daniel E. [Enrico Fermi Institute, Department of Physics, and Kavli Institute for Cosmological Physics University of Chicago, Chicago, IL 60637 (United States); Pannarale, Francesco [School of Physics and Astronomy, Cardiff University, The Parade, Cardiff CF24 3AA (United Kingdom)

    2015-06-20

    The unprecedented range of second-generation gravitational-wave (GW) observatories calls for refining the predictions of potential sources and detection rates. The coalescence of double compact objects (DCOs)—i.e., neutron star–neutron star (NS–NS), black hole–neutron star (BH–NS), and black hole–black hole (BH–BH) binary systems—is the most promising source of GWs for these detectors. We compute detection rates of coalescing DCOs in second-generation GW detectors using the latest models for their cosmological evolution, and implementing inspiral-merger-ringdown gravitational waveform models in our signal-to-noise ratio calculations. We find that (1) the inclusion of the merger/ringdown portion of the signal does not significantly affect rates for NS–NS and BH–NS systems, but it boosts rates by a factor of ∼1.5 for BH–BH systems; (2) in almost all of our models BH–BH systems yield by far the largest rates, followed by NS–NS and BH–NS systems, respectively; and (3) a majority of the detectable BH–BH systems were formed in the early universe in low-metallicity environments. We make predictions for the distributions of detected binaries and discuss what the first GW detections will teach us about the astrophysics underlying binary formation and evolution.

  18. Novel Method For Low-Rate Ddos Attack Detection

    Science.gov (United States)

    Chistokhodova, A. A.; Sidorov, I. D.

    2018-05-01

    The relevance of the work is associated with an increasing number of advanced types of DDoS attacks, in particular, low-rate HTTP-flood. Last year, the power and complexity of such attacks increased significantly. The article is devoted to the analysis of DDoS attacks detecting methods and their modifications with the purpose of increasing the accuracy of DDoS attack detection. The article details low-rate attacks features in comparison with conventional DDoS attacks. During the analysis, significant shortcomings of the available method for detecting low-rate DDoS attacks were found. Thus, the result of the study is an informal description of a new method for detecting low-rate denial-of-service attacks. The architecture of the stand for approbation of the method is developed. At the current stage of the study, it is possible to improve the efficiency of an already existing method by using a classifier with memory, as well as additional information.

  19. Rate modulation detection thresholds for cochlear implant users.

    Science.gov (United States)

    Brochier, Tim; McKay, Colette; McDermott, Hugh

    2018-02-01

    The perception of temporal amplitude modulations is critical for speech understanding by cochlear implant (CI) users. The present study compared the ability of CI users to detect sinusoidal modulations of the electrical stimulation rate and current level, at different presentation levels (80% and 40% of the dynamic range) and modulation frequencies (10 and 100 Hz). Rate modulation detection thresholds (RMDTs) and amplitude modulation detection thresholds (AMDTs) were measured and compared to assess whether there was a perceptual advantage to either modulation method. Both RMDTs and AMDTs improved with increasing presentation level and decreasing modulation frequency. RMDTs and AMDTs were correlated, indicating that a common processing mechanism may underlie the perception of rate modulation and amplitude modulation, or that some subject-dependent factors affect both types of modulation detection.

  20. Obesity detection rate among primary school students in the People's Republic of China: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Jin Y

    2013-10-01

    Full Text Available Yue-long Jin,* Ling-ling Ding,* Ying-shui Yao, Xiu-li Song, Hui Tang, Lian-ping He, Yan ChenFaculty of Epidemiology and Statistics, School of Public Health, Wannan Medical College, Anhui, People's Republic of China*These authors contributed equally to this workBackground: Obesity has become a major public health problem worldwide. The prevalence of obesity is rising alarmingly among children and adolescents in the People's Republic of China, with an estimated 120 million now in the obese range. It is estimated that 8% of children in the People's Republic of China are obese and 12% are overweight.Methods: Eligible papers on the prevalence of obesity among primary school students in the People's Republic of China and published between 2006 and 2011 were retrieved from PubMed and from online Chinese periodicals, ie, the full-text databases of VIP, the Chinese National Knowledge Infrastructure, and Wan Fang. Meta-Analyst software was used to collate and analyze the detection rates cited in the papers retrieved.Results: After evaluation of the quality of the papers, 25 were finally included, giving a total sample population size for investigation of obesity of 219,763, in which 28,121 cases were detected. Meta-analysis showed that the combined obesity detection rate was 10.4% (95% confidence interval 8.6–12.6 among primary school students in the People's Republic of China, with a higher detection rate in boys (12.6% than in girls (7.2%. The prevalence of obesity was higher in the north (11.8% than in the south (9.5%, east (11.6%, and mid-west (8.0% regions. Obesity defined according to the World Health Organization weight-for-height standard (14.3% was higher than that using age-specific and gender-specific cutoff points for body mass index (9.0%.Conclusion: Our meta-analysis found an obesity prevalence rate of 10.4%, which does not seem as high as previous reports of childhood obesity rates in other countries. However, the prevalence of childhood

  1. New system for higher recovery rate of water borne Cryptosporidium oocysts and Giardia cysts

    DEFF Research Database (Denmark)

    Al-Sabi, Mohammad Nafi Solaiman; Gad, Jens; Klinting, Mette

    2012-01-01

    Background: The two most common water borne pathogenic protozoa, Cryptosporidium and Giardia, cause diarrhea worldwide. Detecting these parasites in water samples depends on effective parasite recovery from the water matrix. The reported low recovery rates of the currently used filter methods...... motivate the development of systems with higher recovery rates. Materials and methods: Five replicates of IMS purified Cryptosporidium oocysts and Giardia cysts (N=2x103) were injected into a specially coated filter unit with a carefully chosen pore size. Following filtration, sonication was performed...... were 85% were recorded when the filter was sonicated. Sonication usually affects parasite viability but could be tuned into a useful tool for enhanced backwash collection of parasites using a specially constructed filter unit and a sonication protocol. The filtration...

  2. Internet addiction detection rate among college students in the People's Republic of China: a meta-analysis.

    Science.gov (United States)

    Shao, Yao-Jun; Zheng, Tong; Wang, Yan-Qiu; Liu, Ling; Chen, Yan; Yao, Ying-Shui

    2018-01-01

    With the development of economy and technology, the Internet is becoming more and more popular. Internet addiction has gradually become a serious issue in public health worldwide. The number of Internet users in China has reached 731 million, with an estimated 24 million adolescents determined as having Internet addiction. In this meta-analysis, we attempted to estimate the prevalence of Internet addiction among College Students in the People's Republic of China in order to improve the mental health level of college students and provide evidence for the prevention of Internet addiction. Eligible articles about the prevalence of Internet addiction among college students in China published between 2006 and 2017 were retrieved from online Chinese periodicals, the full-text databases of Wan Fang, VIP, and the Chinese National Knowledge Infrastructure, as well as PubMed. Stata 11.0 was used to perform the analyses. A total of 26 papers were included in the analyses. The overall sample size was 38,245, with 4573 diagnosed with Internet addiction. The pooled detection rate of Internet addiction was 11% (95% confidence interval [CI] 9-13%) among college students in China. The detection rate was higher in male students (16%) than female students (8%). The Internet addiction detection rate was 11% (95% CI 8-14%) in southern areas, 11% (95% CI 7-14%) in northern areas, 13% (95% CI 8-18%) in eastern areas and 9% (95% CI 8-11%) in the mid-western areas. According to different scales, the Internet addiction detection rate was 11% (95% CI 8-15%) using the Young scale and 9% (95% CI 6-11%) using the Chen scale respectively. Cumulative meta analysis showed that the detection rate had a slight upward trend and gradually stabilized in the last 3 years. The pooled Internet addiction detection rate of Chinese college students in out study was 11%, which is higher than in some other countries and strongly demonstrates a worrisome situation. Effective measures should be taken to prevent

  3. Doppler Radar Vital Signs Detection Method Based on Higher Order Cyclostationary.

    Science.gov (United States)

    Yu, Zhibin; Zhao, Duo; Zhang, Zhiqiang

    2017-12-26

    Due to the non-contact nature, using Doppler radar sensors to detect vital signs such as heart and respiration rates of a human subject is getting more and more attention. However, the related detection-method research meets lots of challenges due to electromagnetic interferences, clutter and random motion interferences. In this paper, a novel third-order cyclic cummulant (TOCC) detection method, which is insensitive to Gaussian interference and non-cyclic signals, is proposed to investigate the heart and respiration rate based on continuous wave Doppler radars. The k -th order cyclostationary properties of the radar signal with hidden periodicities and random motions are analyzed. The third-order cyclostationary detection theory of the heart and respiration rate is studied. Experimental results show that the third-order cyclostationary approach has better estimation accuracy for detecting the vital signs from the received radar signal under low SNR, strong clutter noise and random motion interferences.

  4. Social motivation in prospective memory: higher importance ratings and reported performance rates for social tasks.

    Science.gov (United States)

    Penningroth, Suzanna L; Scott, Walter D; Freuen, Margaret

    2011-03-01

    Few studies have addressed social motivation in prospective memory (PM). In a pilot study and two main studies, we examined whether social PM tasks possess a motivational advantage over nonsocial PM tasks. In the pilot study and Study 1, participants listed their real-life important and less important PM tasks. Independent raters categorized the PM tasks as social or nonsocial. Results from both studies showed a higher proportion of tasks rated as social when important tasks were requested than when less important tasks were requested. In Study 1, participants also reported whether they had remembered to perform each PM task. Reported performance rates were higher for tasks rated as social than for those rated as nonsocial. Finally, in Study 2, participants rated the importance of two hypothetical PM tasks, one social and one nonsocial. The social PM task was rated higher in importance. Overall, these findings suggest that social PM tasks are viewed as more important than nonsocial PM tasks and they are more likely to be performed. We propose that consideration of the social relevance of PM will lead to a more complete and ecologically valid theoretical description of PM performance. (PsycINFO Database Record (c) 2011 APA, all rights reserved).

  5. Detection limit for rate fluctuations in inhomogeneous Poisson processes

    Science.gov (United States)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  6. Detection limit for rate fluctuations in inhomogeneous Poisson processes.

    Science.gov (United States)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  7. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  8. Rich or poor: Who should pay higher tax rates?

    Science.gov (United States)

    Murilo Castro de Oliveira, Paulo

    2017-08-01

    A dynamic agent model is introduced with an annual random wealth multiplicative process followed by taxes paid according to a linear wealth-dependent tax rate. If poor agents pay higher tax rates than rich agents, eventually all wealth becomes concentrated in the hands of a single agent. By contrast, if poor agents are subject to lower tax rates, the economic collective process continues forever.

  9. Cooperation schemes for rate enhancement in detect-and-forward relay channels

    KAUST Repository

    Benjillali, Mustapha

    2010-05-01

    To improve the spectral efficiency of "Detect-and-Forward" (DetF) half-duplex relaying in fading channels, we propose a cooperation scheme where the relay uses a modulation whose order is higher than the one at the source. In a new common framework, we show that the proposed scheme offers considerable gains - in terms of achievable information rates - compared to the conventional DetF relaying schemes for both orthogonal and non-orthogonal source/relay cooperation. This allows us to propose an adaptive cooperation scheme based on the maximization of the information rate at the destination which needs to observe only the average signal-to-noise ratios of direct and relaying links. ©2010 IEEE.

  10. Probability of detection of clinical seizures using heart rate changes.

    Science.gov (United States)

    Osorio, Ivan; Manly, B F J

    2015-08-01

    Heart rate-based seizure detection is a viable complement or alternative to ECoG/EEG. This study investigates the role of various biological factors on the probability of clinical seizure detection using heart rate. Regression models were applied to 266 clinical seizures recorded from 72 subjects to investigate if factors such as age, gender, years with epilepsy, etiology, seizure site origin, seizure class, and data collection centers, among others, shape the probability of EKG-based seizure detection. Clinical seizure detection probability based on heart rate changes, is significantly (pprobability of detecting clinical seizures (>0.8 in the majority of subjects) using heart rate is highest for complex partial seizures, increases with a patient's years with epilepsy, is lower for females than for males and is unrelated to the side of hemisphere origin. Clinical seizure detection probability using heart rate is multi-factorially dependent and sufficiently high (>0.8) in most cases to be clinically useful. Knowledge of the role that these factors play in shaping said probability will enhance its applicability and usefulness. Heart rate is a reliable and practical signal for extra-cerebral detection of clinical seizures originating from or spreading to central autonomic network structures. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  11. Factors influencing the detection rate of drug-related problems in community pharmacy

    DEFF Research Database (Denmark)

    Westerlund, T; Almarsdóttir, Anna Birna; Melander, A

    1999-01-01

    This study analyzes relationships between the number of drug-related problems detected in community pharmacy practice and the educational level and other characteristics of pharmacy personnel and their work sites. Random samples of pharmacists, prescriptionists and pharmacy technicians were drawn...... by each professional. The regression analysis showed the educational level of the professional to have a statistically significant effect on the detection rate, with pharmacists finding on average 2.5 more drug-related problems per 100 patients than prescriptionists and about 3.6 more than technicians....... The results of this study indicate the importance of education and training of pharmacy personnel in detection of drug-related problems. This findings speaks in favor of increasing the pharmacist to other personnel ratio, provided the higher costs will be offset by societal benefits....

  12. Poor glycemic control of diabetes mellitus is associated with higher risk of prostate cancer detection in a biopsy population.

    Directory of Open Access Journals (Sweden)

    Juhyun Park

    Full Text Available To evaluate the impact of glycemic control of diabetes mellitus (DM on prostate cancer detection in a biopsy population.We retrospectively reviewed the records of 1,368 men who underwent prostate biopsy at our institution. We divided our biopsy population into three groups according to their history of DM, and their Hemoglobin A1c (HbA1c level: a no-DM (DM- group; a good glycemic control (DM+GC group (HbA1c <6.5%; and a poor glycemic control (DM+PC group (HbA1c ≥6.5%. For sub-analyses, the DM+PC group was divided into a moderately poor glycemic control (DM+mPC group (6.5≤ HbA1c <7.5% and a severely poor glycemic control (DM+sPC group (HbA1c ≥7.5%.Among 1,368 men, 338 (24.7% had a history of DM, and 393 (28.7% had a positive biopsy. There was a significant difference in prostatic specific antigen density (PSAD (P = 0.037 and the frequency of abnormal DRE findings (P = 0.031 among three groups. The occurrence rate of overall prostate cancer (P<0.001 and high-grade prostate cancer (P = 0.016 also presented with a significantly difference. In the multivariate analysis, the DM+PC group was significantly associated with a higher rate of overall prostate cancer detection in biopsy subjects compared to the DM- group (OR = 2.313, P = 0.001 but the DM+PC group was not associated with a higher rate of high-grade (Gleason score ≥7 diseases detected during the biopsy (OR = 1.297, P = 0.376. However, in subgroup analysis, DM+sPC group was significantly related to a higher risk of high-grade diseases compared to the DM- group (OR = 2.446, P = 0.048.Poor glycemic control of DM was associated with a higher risk of prostate cancer detection, including high-grade disease, in the biopsy population.

  13. Leak rate measurements and detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.; Shack, W.J.; Claytor, T.

    1983-10-01

    A research program is under way to evaluate and develop improve leak detection systems. The primary focus of the work has been on acoustic emission detection of leaks. Leaks from artificial flaws, laboratory-generated IGSCCs and thermal fatigue cracks, and field-induced intergranular stress corrosion cracks (IGSCCs) from reactor piping have been examined. The effects of pressure, temperature, and leak rate and geometry on the acoustic signature are under study. The use of cross-correlation techniques for leak location and pattern recognition and autocorrelation for source discrimination is also being considered

  14. Dedicated Barrett's surveillance sessions managed by trained endoscopists improve dysplasia detection rate.

    Science.gov (United States)

    Ooi, Joanne; Wilson, Patrick; Walker, Giles; Blaker, Paul; DeMartino, Sabina; O'Donohue, John; Reffitt, David; Lanaspre, Effie; Chang, Fuju; Meenan, John; Dunn, Jason M

    2017-06-01

    Background and study aim  Barrett's esophagus (BE)-associated dysplasia is an important marker for risk of progression to esophageal adenocarcinoma (EAC) and an indication for endoscopic therapy. However, BE surveillance technique is variable. The aim of this study was to assess the effect of dedicated BE surveillance lists on dysplasia detection rate (DDR). Patients and methods  This was a prospective study of patients undergoing BE surveillance at two hospitals - community (UHL) and upper gastrointestinal center (GSTT). Four endoscopists (Group A) were trained in Prague classification, Seattle protocol biopsy technique, and lesion detection prior to performing BE surveillance endoscopies at both sites, with dedicated time slots or lists. The DDR was then compared with historical data from 47 different endoscopists at GSTT and 24 at UHL (Group B) who had undertaken Barrett's surveillance over the preceding 5-year period. Results  A total of 729 patients with BE underwent surveillance endoscopy between 2007 and 2012. There was no significant difference in patient age, sex, or length of BE between the two groups. There was a significant difference in detection rate of confirmed indefinite or low grade dysplasia and high grade dysplasia (HGD)/EAC between the two groups: 18 % (26 /142) Group A vs. 8 % (45/587) in Group B ( P  < 0.001). Documentation of Prague criteria and adherence to the Seattle protocol was significantly higher in Group A. Conclusion  This study demonstrated that a group of trained endoscopists undertaking Barrett's surveillance on dedicated lists had significantly higher DDR than a nonspecialist cohort. These findings support the introduction of dedicated Barrett's surveillance lists. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Novel Fingertip Image-Based Heart Rate Detection Methods for a Smartphone

    Directory of Open Access Journals (Sweden)

    Rifat Zaman

    2017-02-01

    Full Text Available We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

  16. BIRDNEST: Bayesian Inference for Ratings-Fraud Detection

    OpenAIRE

    Hooi, Bryan; Shah, Neil; Beutel, Alex; Gunnemann, Stephan; Akoglu, Leman; Kumar, Mohit; Makhija, Disha; Faloutsos, Christos

    2015-01-01

    Review fraud is a pervasive problem in online commerce, in which fraudulent sellers write or purchase fake reviews to manipulate perception of their products and services. Fake reviews are often detected based on several signs, including 1) they occur in short bursts of time; 2) fraudulent user accounts have skewed rating distributions. However, these may both be true in any given dataset. Hence, in this paper, we propose an approach for detecting fraudulent reviews which combines these 2 app...

  17. Narrow Band Imaging Enhances the Detection Rate of Penetration and Aspiration in FEES.

    Science.gov (United States)

    Nienstedt, Julie C; Müller, Frank; Nießen, Almut; Fleischer, Susanne; Koseki, Jana-Christiane; Flügel, Till; Pflug, Christina

    2017-06-01

    Narrow band imaging (NBI) is widely used in gastrointestinal, laryngeal, and urological endoscopy. Its original purpose was to visualize vessels and epithelial irregularities. Based on our observation that adding NBI to common white light (WL) improves the contrast of the test bolus in fiberoptic endoscopic evaluation of swallowing (FEES), we now investigated the potential value of NBI in swallowing disorders. 148 FEES images were analyzed from 74 consecutive patients with swallowing disorders, including 74 with and 74 without NBI. All images were evaluated by four dysphagia specialists. Findings were classified according to Rosenbek's penetration-aspiration scale modified for evaluating these FEES images. Intra- and inter-rater reliability was determined as well as observer confidence. A better visualization of the bolus is the main advantage of NBI in FEES. This generally leads to sharper optical contrasts and better detection of small bolus quantities. Accordingly, NBI enhances the detection rate of penetration and aspiration. On average, identification of laryngeal penetration increased from 40 to 73% and of aspiration from 13 to 24% (each p dysphagia evaluation and shortening FEES evaluation time. It leads to a markedly higher detection rate of pathological findings. The significantly better intra- and inter-rater reliability argues further for a better overall reproducibly of FEES interpretation.

  18. Probabilistic pipe fracture evaluations for leak-rate-detection applications

    International Nuclear Information System (INIS)

    Rahman, S.; Ghadiali, N.; Paul, D.; Wilkowski, G.

    1995-04-01

    Regulatory Guide 1.45, open-quotes Reactor Coolant Pressure Boundary Leakage Detection Systems,close quotes was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, open-quotes Leak Before Break Evaluation Proceduresclose quotes where a margin of 10 on the leak detection limit is used in determining the crack size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break

  19. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  20. Detection rate of prostate cancer using prostate specific antigen in patients presenting with lower urinary tract symptoms: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chavan P

    2009-01-01

    Full Text Available Background: Need for undertaking prostate biopsies for detection of prostate cancer is often decided on the basis of serum levels of prostate specific antigen (PSA. Aim: To evaluate the case detection rate of prostate cancer among patients presenting with lower urinary tract symptoms (LUTS on the basis of PSA levels and to assess the scope of prostate biopsy in these patients. Setting and Design: A retrospective study from a tertiary care center. Materials and Methods: The clinical and histopathological data of 922 patients presenting with LUTS in the last five years was obtained from the medical record section. They had been screened for prostate cancer using PSA and /or digital rectal examination examination followed by confirmation with prostate biopsy. Statistical Analysis Used: Detection rate and receiver operating characteristic curve were performed using SPSS 16 and Medcalc softwares. Results: The detection rate of prostate cancer according to the PSA levels was 0.6%, 2.3%, 2.5%, 34.1% and 54.9% in the PSA range of 0-4, 4-10, 10-20, 20-50 and> 50 ng/ml, respectively. Maximum prostate cancer cases were detected beyond a PSA value of 20 ng/ml whereas no significant difference in the detection rate was observed in the PSA range of 0-4, 4-10 and 10-20 ng/ml. Conclusion: A low detection rate of prostate cancer observed in the PSA range of 4-20 ng/ml in LUTS patients indicates the need for use of higher cutoff values of PSA in such cases. Therefore we recommend a cutoff of 20 ng/ml of PSA for evaluation of detection rate of prostate cancer among patients presenting with LUTS.

  1. Impact of the use of an endorectal coil for 3 T prostate MRI on image quality and cancer detection rate.

    Science.gov (United States)

    Gawlitza, Josephin; Reiss-Zimmermann, Martin; Thörmer, Gregor; Schaudinn, Alexander; Linder, Nicolas; Garnov, Nikita; Horn, Lars-Christian; Minh, Do Hoang; Ganzer, Roman; Stolzenburg, Jens-Uwe; Kahn, Thomas; Moche, Michael; Busse, Harald

    2017-02-01

    This work aims to assess the impact of an additional endorectal coil on image quality and cancer detection rate within the same patients. At a single academic medical center, this transversal study included 41 men who underwent T2- and diffusion-weighted imaging at 3 T using surface coils only or in combination with an endorectal coil in the same session. Two blinded readers (A and B) randomly evaluated all image data in separate sessions. Image quality with respect to localization and staging was rated on a five-point scale. Lesions were classified according to their prostate imaging reporting and data system (PIRADS) score version 1. Standard of reference was provided by whole-mount step-section analysis. Mean image quality scores averaged over all localization-related items were significantly higher with additional endorectal coil for both readers (p < 0.001), corresponding staging-related items were only higher for reader B (p < 0.001). With an endorectal coil, the rate of correctly detecting cancer per patient was significantly higher for reader B (p < 0.001) but not for reader A (p = 0.219). The numbers of histologically confirmed tumor lesions were rather similar for both settings. The subjectively rated 3-T image quality was improved with an endorectal coil. In terms of diagnostic performance, the use of an additional endorectal coil was not superior.

  2. [Detection rates of overweight and obesity in children and adolescents with different ethnicities in Xinjiang Uigur areas].

    Science.gov (United States)

    Li, Haixia; Li, Xiaomei; Tao, Jing; Ma, Yitong; Yang, Yining; Liu, Fen; Chen, Bangdang; Xie, Xiang; Yang, Hong

    2014-01-01

    To investigate the detection rates of overweight and obesity among Han,Uygur and Kazakh Children and adolescents in Xinjiang. Random samples were used to analyze the detection rates on overweight and obesity based on data from Han,Uygur and Kazakh Children and adolescents aged 7-14 years from 3 regions-Hetian, Kashi and Fuhai prefectures in Xinjiang Uygur Autonomous Region. Anthropometric data including weight and height was collected. Overweight and obesity were defined according to body mass index [BMI, weight (kg)/height (m²)] cutoffs recommended by the Chinese Working Group on Obesity for Children (WGOC)aged 7-14 years. The present study was performed in 11 894 Han, Uygur and Kazakh Children and adolescents aged 7-14 years. The overall prevalence rates of overweight and obesity were 5.6% and 2.9% respectively, which the difference between male and female was significant (χ² = 39.765, P overweight and obesity rate showed differences, with detection rate of overweight among Kazakh students was 12.0% , higher than the other ethnic groups. The obesity detection rate was 7.2% among Han students, which was the highest of the three ethnic groups, with differences statistically significant(χ² = 363.885, P overweight and obesity decreased with increasing age in various ethnic groups, showing a clear downward trend, with the peak at 7-9 year-olds and the difference was statistically significant(χ² = 101.479, P overweight and obesity among children and adolescents were significantly lower in Xinjiang Uygur Autonomous Region than the national average level, with differences also seen in different ethnic, gender and age groups.

  3. Higher rates of sex evolve in spatially heterogeneous environments.

    Science.gov (United States)

    Becks, Lutz; Agrawal, Aneil F

    2010-11-04

    The evolution and maintenance of sexual reproduction has puzzled biologists for decades. Although this field is rich in hypotheses, experimental evidence is scarce. Some important experiments have demonstrated differences in evolutionary rates between sexual and asexual populations; other experiments have documented evolutionary changes in phenomena related to genetic mixing, such as recombination and selfing. However, direct experiments of the evolution of sex within populations are extremely rare (but see ref. 12). Here we use the rotifer, Brachionus calyciflorus, which is capable of both sexual and asexual reproduction, to test recent theory predicting that there is more opportunity for sex to evolve in spatially heterogeneous environments. Replicated experimental populations of rotifers were maintained in homogeneous environments, composed of either high- or low-quality food habitats, or in heterogeneous environments that consisted of a mix of the two habitats. For populations maintained in either type of homogeneous environment, the rate of sex evolves rapidly towards zero. In contrast, higher rates of sex evolve in populations experiencing spatially heterogeneous environments. The data indicate that the higher level of sex observed under heterogeneity is not due to sex being less costly or selection against sex being less efficient; rather sex is sufficiently advantageous in heterogeneous environments to overwhelm its inherent costs. Counter to some alternative theories for the evolution of sex, there is no evidence that genetic drift plays any part in the evolution of sex in these populations.

  4. PET-CT detection rate of primary breast cancer lesions. Correlation with the clinicopathological factors

    International Nuclear Information System (INIS)

    Ogawa, Tomoko; Tozaki, Mitsuhiro; Fukuma, Eisuke

    2008-01-01

    One hundred and forty lesions of primary breast cancer underwent positron emission tomography (PET)-CT between June 2006 and May 2007. The PET-CT detection rate of primary breast cancer lesions was 72.1%. The detection rate was 52.1% for invasive cancer ≤20 mm, 92.8% for invasive breast cancers >20 mm, and these results were significant. In the present study, no significant relationship was observed between tumor types, however, invasive lobular carcinoma showed a lower detection rate, 58.3%. The PET-CT results were not significantly affected by either estrogen and progesterone receptors or distant metastasis. A significant correlation regarding the detection rate of PET-CT was found with HER2 status, tumor grade, and axillary lymph node status. The detection rate was 100% for invasive cancer ≤20 mm when the interval between prior diagnostic Mammotome biopsies and PET-CT was less than 3 weeks, 18.8% for invasive cancer ≤20 mm when the interval was more than 3 weeks, and these results were significant. Mammotome biopsies may therefore affect the detection rate of PET-CT. Invasive cancers ≤20 mm showed a low detection rate, therefore, it is considered to be insufficient to use PET-CT for the detection of early breast cancer. (author)

  5. Enabling Higher Data Rates for Planetary Science Missions

    Science.gov (United States)

    Deutsch, L. J.; Townes, S. A.; Lazio, J.; Bell, D. J.; Chahat, N. E.; Kovalik, J. M.; Kuperman, I.; Sauder, J.; Liebrecht, P. E.

    2017-12-01

    The data rate from deep space spacecraft has increased by more than 10 orders of magnitude since the first lunar missions in the 1960s. The demand for increased data rates has stemmed from the increasing sophistication of the science questions being addressed and the concomitant increase in the complexity of the missions themselves (from fly-by to orbit to land and rove). Projections for the next few decades suggest the demand for data rates for deep space missions will continue to increase by approximately one order of magnitude every decade, driven by these same factors. Achieving higher data rates requires a partnership between the spacecraft and the ground system. We describe a series of technology developments for flight telecommunications systems, both at radio frequency (RF) and optical, to enable spacecraft to transmit and receive larger data volumes. These technology developments include deployable high gain antennas for small spacecraft, re-programmable software-defined radios, and optical communication packages designed for CubeSat form factors. The intent is that these developments would provide enhancements in capability for both spacecraft-Earth and spacecraft-spacecraft telecommunications. We also describe the future planning for NASA's Deep Space Network (DSN), which remains the prime conduit for data from all planetary science missions. Through a combination of new antennas and backends being installed over the next five years and incorporation of optical communications, the DSN aims to ensure that the historical improvements in data rates and volumes will continue for many decades. Part of this research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.

  6. Adenoma detection rate varies greatly during colonoscopy training

    NARCIS (Netherlands)

    van Doorn, Sascha C.; Klanderman, Robert B.; Hazewinkel, Yark; Fockens, Paul; Dekker, Evelien

    2015-01-01

    The adenoma detection rate (ADR) is considered the most important quality indicator for colonoscopy and varies widely among colonoscopists. It is unknown whether the ADR of gastroenterology consultants can already be predicted during their colonoscopy training. To evaluate the ADR of fellows in

  7. A High Performance Impedance-based Platform for Evaporation Rate Detection.

    Science.gov (United States)

    Chou, Wei-Lung; Lee, Pee-Yew; Chen, Cheng-You; Lin, Yu-Hsin; Lin, Yung-Sheng

    2016-10-17

    This paper describes the method of a novel impedance-based platform for the detection of the evaporation rate. The model compound hyaluronic acid was employed here for demonstration purposes. Multiple evaporation tests on the model compound as a humectant with various concentrations in solutions were conducted for comparison purposes. A conventional weight loss approach is known as the most straightforward, but time-consuming, measurement technique for evaporation rate detection. Yet, a clear disadvantage is that a large volume of sample is required and multiple sample tests cannot be conducted at the same time. For the first time in literature, an electrical impedance sensing chip is successfully applied to a real-time evaporation investigation in a time sharing, continuous and automatic manner. Moreover, as little as 0.5 ml of test samples is required in this impedance-based apparatus, and a large impedance variation is demonstrated among various dilute solutions. The proposed high-sensitivity and fast-response impedance sensing system is found to outperform a conventional weight loss approach in terms of evaporation rate detection.

  8. Interference of detection rate of lumbar disc herniation by socioeconomic status.

    Science.gov (United States)

    Ji, Gyu Yeul; Oh, Chang Hyun; Jung, Nak-Yong; An, Seong Dae; Choi, Won-Seok; Kim, Jung Hoon

    2013-03-01

    Retrospective study. The objective of the study is to evaluate the relationship between the detection rate of lumbar disc herniation and socioeconomic status. Income is one important determinant of public health. Yet, there are no reports about the relationship between socioeconomic status and the detective rate of disc herniation. In this study, 443 cases were checked for lumbar computed tomography for lumbar disc herniation, and they reviewed questionnaires about their socioeconomic status, the presence of back pain or radiating pain and the presence of a medical certificate (to check the medical or surgical treatment for the pain) during the Korean conscription. Without the consideration for the presence of a medical certificate, there was no difference in spinal physical grade according to socioeconomic status (p=0.290). But, with the consideration of the presence of a medical certificate, the significant statistical differences were observed according to socioeconomic status in 249 cases in the presence of a medical certificate (p=0.028). There was a lower detection rate in low economic status individuals than those in the high economic class. The common reason for not submitting a medical certificate is that it is neither necessary for the people of lower socioeconomic status nor is it financially affordable. The prevalence of lumbar disc herniation is not different according to socioeconomic status, but the detective rate was affected by socioeconomic status. Socioeconomic status is an important factor for detecting lumbar disc herniation.

  9. Fault Detection Using the Zero Crossing Rate | Osuagwu | Nigerian ...

    African Journals Online (AJOL)

    A method of fault detection based on the zero crossing rate of the signal, Z1, and the zero crossing rate of the first order difference signal. Z2, is presented. It is shown that the parameter pair (Z1, Z2) possesses adequate discriminating potential to classify a signature as good or defective. The parameter pair also carries ...

  10. Low-Rate DDoS Attack Detection Using Expectation of Packet Size

    Directory of Open Access Journals (Sweden)

    Lu Zhou

    2017-01-01

    Full Text Available Low-rate Distributed Denial-of-Service (low-rate DDoS attacks are a new challenge to cyberspace, as the attackers send a large amount of attack packets similar to normal traffic, to throttle legitimate flows. In this paper, we propose a measurement—expectation of packet size—that is based on the distribution difference of the packet size to distinguish two typical low-rate DDoS attacks, the constant attack and the pulsing attack, from legitimate traffic. The experimental results, obtained using a series of real datasets with different times and different tolerance factors, are presented to demonstrate the effectiveness of the proposed measurement. In addition, extensive experiments are performed to show that the proposed measurement can detect the low-rate DDoS attacks not only in the short and long terms but also for low packet rates and high packet rates. Furthermore, the false-negative rates and the adjudication distance can be adjusted based on the detection sensitivity requirements.

  11. United States private schools have higher rates of exemptions to school immunization requirements than public schools.

    Science.gov (United States)

    Shaw, Jana; Tserenpuntsag, Boldtsetseg; McNutt, Louise-Anne; Halsey, Neal

    2014-07-01

    To compare medical, religious, and personal belief immunization exemption rates between private and public schools in US. Exemption rates were calculated using the Centers for Disease Control and Prevention School Immunization Assessment Surveys for the 2009-2010 school year excluding states with incomplete survey data. Standardized exemption rates weighted on enrollments in public and private schools were calculated. Differences in exemption rates between public and private schools were tested using Wilcoxon signed rank test. The overall state exemption rate was higher in US private than public schools, 4.25% (SD 4.27) vs 1.91% (1.67), P = .0001 and private schools had higher exemption rates for all types of exemptions; medical 0.58% (0.71) vs 0.34% (0.34) respectively (P = .0004), religious 2.09% (3.14) vs 0.83% (1.05) respectively (P = .0001), and personal belief 6.10% (4.12) vs 2.79% (1.57), respectively (P = .006). Overall exemption rates were significantly higher in states that allowed personal belief exemptions. Exemption rates were significantly higher in US private than in public schools. Children attending private schools may be at higher risk of vaccine-preventable diseases than public school children. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Vastus Lateralis Motor Unit Firing Rate Is Higher in Women With Patellofemoral Pain.

    Science.gov (United States)

    Gallina, Alessio; Hunt, Michael A; Hodges, Paul W; Garland, S Jayne

    2018-05-01

    To compare neural drive, determined from motor unit firing rate, in the vastus medialis and lateralis in women with and without patellofemoral pain. Cross-sectional study. University research laboratory. Women (N=56) 19 to 35 years of age, including 36 with patellofemoral pain and 20 controls. Not applicable. Participants sustained an isometric knee extension contraction at 10% of their maximal voluntary effort for 70 seconds. Motor units (N=414) were identified using high-density surface electromyography. Average firing rate was calculated between 5 and 35 seconds after recruitment for each motor unit. Initial firing rate was the inverse of the first 3 motor unit interspike intervals. In control participants, vastus medialis motor units discharged at higher rates than vastus lateralis motor units (P=.001). This was not observed in women with patellofemoral pain (P=.78) because of a higher discharge rate of vastus lateralis compared with control participants (P=.002). No between-group differences were observed for vastus medialis (P=.93). Similar results were obtained for the initial motor unit firing rate. These findings suggest that women with patellofemoral pain have a higher neural drive to vastus lateralis but not vastus medialis, which may be a contributor of the altered patellar kinematics observed in some studies. The different neural drive may be an adaptation to patellofemoral pain, possibly to compensate for decreased quadriceps force production, or a precursor of patellofemoral pain. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Pipe fracture evaluations for leak-rate detection: Probabilistic models

    International Nuclear Information System (INIS)

    Rahman, S.; Wilkowski, G.; Ghadiali, N.

    1993-01-01

    This is the second in series of three papers generated from studies on nuclear pipe fracture evaluations for leak-rate detection. This paper focuses on the development of novel probabilistic models for stochastic performance evaluation of degraded nuclear piping systems. It was accomplished here in three distinct stages. First, a statistical analysis was conducted to characterize various input variables for thermo-hydraulic analysis and elastic-plastic fracture mechanics, such as material properties of pipe, crack morphology variables, and location of cracks found in nuclear piping. Second, a new stochastic model was developed to evaluate performance of degraded piping systems. It is based on accurate deterministic models for thermo-hydraulic and fracture mechanics analyses described in the first paper, statistical characterization of various input variables, and state-of-the-art methods of modem structural reliability theory. From this model. the conditional probability of failure as a function of leak-rate detection capability of the piping systems can be predicted. Third, a numerical example was presented to illustrate the proposed model for piping reliability analyses. Results clearly showed that the model provides satisfactory estimates of conditional failure probability with much less computational effort when compared with those obtained from Monte Carlo simulation. The probabilistic model developed in this paper will be applied to various piping in boiling water reactor and pressurized water reactor plants for leak-rate detection applications

  14. Use of Selective Fungal Culture Media Increases Rates of Detection of Fungi in the Respiratory Tract of Cystic Fibrosis Patients.

    Science.gov (United States)

    Hong, Gina; Miller, Heather B; Allgood, Sarah; Lee, Richard; Lechtzin, Noah; Zhang, Sean X

    2017-04-01

    The prevalence of fungi in the respiratory tracts of cystic fibrosis (CF) patients has risen. However, fungal surveillance is not routinely performed in most clinical centers in the United States, which may lead to an underestimation of the true prevalence of the problem. We conducted a prospective study comparing the rates of detection for clinically important fungi (CIF), defined as Aspergillus , Scedosporium , and Trichosporon species and Exophiala dermatitidis , in CF sputa using standard bacterial and selective fungal culture media, including Sabouraud dextrose agar with gentamicin (SDA), inhibitory mold agar (IMA), and brain heart infusion (BHI) agar with chloramphenicol and gentamicin. We described the prevalence of these fungi in an adult CF population. A total of 487 CF respiratory samples were collected from 211 unique participants. CIF were detected in 184 (37.8%) samples. Only 26.1% of CIF-positive samples were detected in bacterial culture medium, whereas greater rates of detection for fungi were found in IMA (65.8%; P culture media and longer incubation periods yielded higher rates of detection for CIF in CF sputum samples compared with that detected in bacterial culture medium, resulting in an underdetection of fungi by bacterial culture alone. The prevalence of fungi in CF may be better estimated by using selective fungal culture media, and this may translate to important clinical decisions. Copyright © 2017 American Society for Microbiology.

  15. Detection and recurrence rate of transurethral resection of bladder tumors by narrow-band imaging: Prospective, randomized comparison with white light cystoscopy

    Directory of Open Access Journals (Sweden)

    Seung Bin Kim

    2018-03-01

    Full Text Available Purpose: The purpose of this study was to evaluate the efficacy of narrow-band imaging (NBI as a diagnostic tool for detecting bladder tumors during cystoscopy compared with white light cystoscopy (WLC. Materials and Methods: From December 2013 to June 2017, a randomized prospective study was conducted on 198 patients underwent transurethral resection of bladder tumor by a single surgeon. The patients were divided into two groups according to diagnostic method. In Group I, WLC only was performed. In Group II, NBI was additionally performed after WLC. We analyzed the rate of detection of bladder tumors as a primary endpoint. In addition, we evaluated rates of recurrence in each group. Results: There were no significant differences between the two groups in characteristics except hypertension. In the analysis of rates of detection, the probability of diagnosing cancer was 80.9% (114/141 in the WLC group, and the probability of diagnosing cancer using WLC in the NBI group was 85.5% (159/186. After switching from WLC to NBI for second-look cystoscopy in the NBI group, NBI was shown to detect additional tumors with a detection rate of 35.1% (13/37 from the perspective of the patients and 42.2% (27/64 from the perspective of the tumors. The 1-year recurrence-free rate was 72.2% in the WLC group and 85.2% in the NBI group (p=0.3. Conclusions: NBI had benefits for detecting tumors overlooked by WLC. Although the difference in the 1-year recurrence-free rate was not statistically significant, our results showed a trend for higher recurrence in the NBI group.

  16. QRS peak detection for heart rate monitoring on Android smartphone

    Science.gov (United States)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  17. Link Between RI-ISI and Inspection Qualification: Relationship between Defect Detection Rate and Margin of Detection

    International Nuclear Information System (INIS)

    Shepherd, Barrie; Goujon, Sophie; Whittle, John

    2007-01-01

    Quantitative risk-informed in-service inspection (RI-ISI) requires a quantitative measurement of inspection effectiveness if the risk change associated with an inspection is to be determined. Knowing the probability of detection (POD) as a function of defect depth (through wall dimension) would provide ideal information. However the main in-service inspection method for nuclear plant is ultrasonics, for which defect detection capability depends on a wide variety of parameters besides defect depth, such as defect orientation, roughness, location, shape etc. In recognition of this the European approach to inspection qualification is generally based on some combination of technical justification, and practical trials on a relatively limited number of defects. This inspection qualification process involves demonstrating that defects of concern will generate responses in excess of the specified recording level or noise, depending on the inspection. It is not currently designed to quantify the probability with which defects will be detected. The work described in this report has been performed in order to help address the problem of how the information generated during inspection qualification can be used as an input for RI-ISI. The approach adopted has been to recognise that as the defect response increases above the recording or noise level, the probability of detecting defects is likely to increase. The work therefore involved an investigation of the relationship between POD (strictly speaking defect detection rate) and margin of detection. It involved blind manual and automated ultrasonic trials on artificial defects in test plates designed to generate a range of signal responses. The detection rate for defects which provided signals at a particular level above noise or above a recording level was then measured. A relationship between defect detection rate and margin of detection has been established based on these trials. In addition to establishing a stronger link

  18. Retrospective observation on contribution and limitations of screening for breast cancer with mammography in Korea: detection rate of breast cancer and incidence rate of interval cancer of the breast.

    Science.gov (United States)

    Lee, Kunsei; Kim, Hyeongsu; Lee, Jung Hyun; Jeong, Hyoseon; Shin, Soon Ae; Han, Taehwa; Seo, Young Lan; Yoo, Youngbum; Nam, Sang Eun; Park, Jong Heon; Park, Yoo Mi

    2016-11-18

    The purpose of this study was to determine the benefits and limitations of screening for breast cancer using mammography. Descriptive design with follow-up was used in the study. Data from breast cancer screening and health insurance claim data were used. The study population consisted of all participants in breast cancer screening from 2009 to 2014. Crude detection rate, positive predictive value and sensitivity and specificity of breast cancer screening and, incidence rate of interval cancer of the breast were calculated. The crude detection rate of breast cancer screening per 100,000 participants increased from 126.3 in 2009 to 182.1 in 2014. The positive predictive value of breast cancer screening per 100,000 positives increased from 741.2 in 2009 to 1,367.9 in 2014. The incidence rate of interval cancer of the breast per 100,000 negatives increased from 51.7 in 2009 to 76.3 in 2014. The sensitivities of screening for breast cancer were 74.6% in 2009 and 75.1% in 2014 and the specificities were 83.1% in 2009 and 85.7% in 2014. To increase the detection rate of breast cancer by breast cancer screening using mammography, the participation rate should be higher and an environment where accurate mammography and reading can be performed and reinforcement of quality control are required. To reduce the incidence rate of interval cancer of the breast, it will be necessary to educate women after their 20s to perform self-examination of the breast once a month regardless of participation in screening for breast cancer.

  19. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    Energy Technology Data Exchange (ETDEWEB)

    Portnoy, David, E-mail: david.portnoy@jhuapl.edu [Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States); Feuerbach, Robert; Heimberg, Jennifer [Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States)

    2011-10-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the 'threat' set of

  20. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    International Nuclear Information System (INIS)

    Portnoy, David; Feuerbach, Robert; Heimberg, Jennifer

    2011-01-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the 'threat' set of spectra

  1. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    Science.gov (United States)

    Portnoy, David; Feuerbach, Robert; Heimberg, Jennifer

    2011-10-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the "threat" set of spectra

  2. A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation.

    Science.gov (United States)

    Chung, Tae Nyoung; Kim, Sun Wook; You, Je Sung; Cho, Young Soon; Chung, Sung Phil; Park, Incheol

    2012-01-01

    Metronome guidance is a simple and economical feedback system for guiding cardiopulmonary resuscitation (CPR). However, a recent study showed that metronome guidance reduced the depth of chest compression. The results of previous studies suggest that a higher chest compression rate is associated with a better CPR outcome as compared with a lower chest compression rate, irrespective of metronome use. Based on this finding, we hypothesized that a lower chest compression rate promotes a reduction in chest compression depth in the recent study rather than metronome use itself. One minute of chest compression-only CPR was performed following the metronome sound played at 1 of 4 different rates: 80, 100, 120, and 140 ticks/min. Average compression depths (ACDs) and duty cycles were compared using repeated measures analysis of variance, and the values in the absence and presence of metronome guidance were compared. Both the ACD and duty cycle increased when the metronome rate increased (P = .017, metronome rates of 80 and 100 ticks/min were significantly lower than those for the procedures without metronome guidance. The ACD and duty cyle for chest compression increase as the metronome rate increases during metronome-guided CPR. A higher rate of chest compression is necessary for metronome-guided CPR to prevent suboptimal quality of chest compression. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Long-term follow-up of the TIPS early detection in psychosis study

    DEFF Research Database (Denmark)

    Simonsen, Erik; Hegelstad, Wenche ten Welden; Larsen, Tor Ketil

    2012-01-01

    ill patients dropping out of the study in the usual-detection area. Except for higher levels of excitative symptoms in the early-detection area, there were no symptom differences between the groups. Early-detection recovery rates were higher largely because of higher employment rates for patients...

  4. Ten-year detection rate of brain arteriovenous malformations in a large, multiethnic, defined population.

    Science.gov (United States)

    Gabriel, Rodney A; Kim, Helen; Sidney, Stephen; McCulloch, Charles E; Singh, Vineeta; Johnston, S Claiborne; Ko, Nerissa U; Achrol, Achal S; Zaroff, Jonathan G; Young, William L

    2010-01-01

    To evaluate whether increased neuroimaging use is associated with increased brain arteriovenous malformation (BAVM) detection, we examined detection rates in the Kaiser Permanente Medical Care Program of northern California between 1995 and 2004. We reviewed medical records, radiology reports, and administrative databases to identify BAVMs, intracranial aneurysms (IAs: subarachnoid hemorrhage [SAH] and unruptured aneurysms), and other vascular malformations (OVMs: dural fistulas, cavernous malformations, Vein of Galen malformations, and venous malformations). Poisson regression (with robust standard errors) was used to test for trend. Random-effects meta-analysis generated a pooled measure of BAVM detection rate from 6 studies. We identified 401 BAVMs (197 ruptured, 204 unruptured), 570 OVMs, and 2892 IAs (2079 SAHs and 813 unruptured IAs). Detection rates per 100 000 person-years were 1.4 (95% CI, 1.3 to 1.6) for BAVMs, 2.0 (95% CI, 1.8 to 2.3) for OVMs, and 10.3 (95% CI, 9.9 to 10.7) for IAs. Neuroimaging utilization increased 12% per year during the time period (PIAs (PIAs (P4) per 100 000 person-years, without heterogeneity between studies (P=0.25). Rates for BAVMs, OVMs, and IAs in this large, multiethnic population were similar to those in other series. During 1995 to 2004, a period of increasing neuroimaging utilization, we did not observe an increased rate of detection of unruptured BAVMs, despite increased detection of unruptured IAs.

  5. Computer-aided detection of pulmonary nodules: influence of nodule characteristics on detection performance

    International Nuclear Information System (INIS)

    Marten, K.; Engelke, C.; Seyfarth, T.; Grillhoesl, A.; Obenauer, S.; Rummeny, E.J.

    2005-01-01

    AIM: To evaluate prospectively the influence of pulmonary nodule characteristics on detection performances of a computer-aided diagnosis (CAD) tool and experienced chest radiologists using multislice CT (MSCT). MATERIALS AND METHODS: MSCT scans of 20 consecutive patients were evaluated by a CAD system and two independent chest radiologists for presence of pulmonary nodules. Nodule size, position, margin, matrix characteristics, vascular and pleural attachments and reader confidence were recorded and data compared with an independent standard of reference. Statistical analysis for predictors influencing nodule detection or reader performance included chi-squared, retrograde stepwise conditional logistic regression with odds ratios and nodule detection proportion estimates (DPE), and ROC analysis. RESULTS: For 135 nodules, detection rates for CAD and readers were 76.3, 52.6 and 52.6%, respectively; false-positive rates were 0.55, 0.25 and 0.15 per examination, respectively. In consensus with CAD the reader detection rate increased to 93.3%, and the false-positive rate dropped to 0.1/scan. DPEs for nodules ≤5 mm were significantly higher for ICAD than for the readers (p<0.05). Absence of vascular attachment was the only significant predictor of nodule detection by CAD (p=0.0006-0.008). There were no predictors of nodule detection for reader consensus with CAD. In contrast, vascular attachment predicted nodule detection by the readers (p=0.0001-0.003). Reader sensitivity was higher for nodules with vascular attachment than for unattached nodules (sensitivities 0.768 and 0.369; 95% confidence intervals=0.651-0.861 and 0.253-0.498, respectively). CONCLUSION: CAD increases nodule detection rates, decreases false-positive rates and compensates for deficient reader performance in detection of smallest lesions and of nodules without vascular attachment

  6. Detection rate of prostate cancer following biopsy among the northern Han Chinese population: a single-center retrospective study of 1022 cases.

    Science.gov (United States)

    Jia, Yong; Zhu, Lei-Yi; Xian, Yu-Xin; Sun, Xiao-Qing; Gao, Jian-Gang; Zhang, Xin-Hong; Hou, Si-Chuan; Zhang, Chang-Cun; Liu, Zhao-Xu

    2017-08-29

    Prostate cancer is known to have ethnic and regional differences. The study aimed to clinically evaluate the detection rate of prostate cancer on transrectal ultrasonography (TRUS)-guided prostate biopsy and analyze its characteristics among the northern Han Chinese population at a single center. Between October 2009 and September 2016, a total of 1027 Chinese men, who had undergone TRUS-guided prostate biopsy at Qingdao Municipal Hospital, were retrospectively analyzed. Prostate biopsies were performed in the case of an abnormally elevated serum PSA level, and/or abnormal digital rectal examination (DRE) findings, and/or suspicious prostatic imaging findings. Of the 1022 men enrolled in the analysis, 438 patients (42.8%) were diagnosed with prostate adenocarcinoma histologically. When serum PSA levels were divided into five subgroups (less than 4.0, 4.0 to 10.0, 10.0 to 20.0, 20.0 to 100.0, and ≥ 100.0 ng/ml), the detection rates of prostate cancer were 12.4, 15.9, 34.1, 66.2, and 93.8%, respectively. With serum PSA levels of 4.0 to 10.0 ng/ml, the cancer detection rates for a normal DRE and a suspect DRE finding were 13.5 and 58.2%, respectively. Accordingly, the cancer detection rates for a normal imaging and a suspect imaging finding were 13.5 and 58.2%, respectively. Besides, a large proportion of the patients were in the clinically advanced stage. The present study data reported a relatively higher prostate cancer detection rate of 42.8% and that the majority of the patients presented with clinically advanced prostate cancers within a local clinical urologic practice. An early detection and screening program for prostate cancer is of great need to reduce the burden from this disease among the northern Han Chinese population.

  7. Technological advances for improving adenoma detection rates: The changing face of colonoscopy.

    Science.gov (United States)

    Ishaq, Sauid; Siau, Keith; Harrison, Elizabeth; Tontini, Gian Eugenio; Hoffman, Arthur; Gross, Seth; Kiesslich, Ralf; Neumann, Helmut

    2017-07-01

    Worldwide, colorectal cancer is the third commonest cancer. Over 90% follow an adenoma-to-cancer sequence over many years. Colonoscopy is the gold standard method for cancer screening and early adenoma detection. However, considerable variation exists between endoscopists' detection rates. This review considers the effects of different endoscopic techniques on adenoma detection. Two areas of technological interest were considered: (1) optical technologies and (2) mechanical technologies. Optical solutions, including FICE, NBI, i-SCAN and high definition colonoscopy showed mixed results. In contrast, mechanical advances, such as cap-assisted colonoscopy, FUSE, EndoCuff and G-EYE™, showed promise, with reported detections rates of up to 69%. However, before definitive recommendations can be made for their incorporation into daily practice, further studies and comparison trials are required. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  8. A Longitudinal Study of Adenoma Detection Rate in Gastroenterology Fellowship Training.

    Science.gov (United States)

    Gianotti, Robert J; Oza, Sveta Shah; Tapper, Elliot B; Kothari, Darshan; Sheth, Sunil G

    2016-10-01

    Current guidelines suggest that a gastroenterology fellow in training needs to perform 140 colonoscopies to achieve competency. Data are limited regarding adenoma detection rate (ADR) in fellowship. To assess how fellow ADR correlates with number of colonoscopies performed. We performed a retrospective study examining consecutive colonoscopies performed by gastroenterology fellows. Fellow ADR before and after the 140 procedure benchmark was compared to colonoscopies performed by attending only with whom these fellows trained. A threshold for ideal procedure count was performed using ROC analysis. We analyzed 2021 average-risk colonoscopies performed by 10 gastroenterology fellows under the supervision of an attending physician. When fellows had performed 140 colonoscopies under attending supervision (p = 0.02). The ADR of fellows who had performed >140 colonoscopies under attending supervision was greater than that of attending-only colonoscopies (36 vs. 25 %, p 325 (male patients) and 539 (female patients) colonoscopies was determined to be ideal for achieving adequate ADR based on ROC analysis. Our data suggest that ADR increases after fellows perform >140 colonoscopies under attending supervision, and thereafter surpasses the ADR of attending-only colonoscopies. Some of the differences may be driven by detection of small adenomas. The findings of this study suggest that a higher threshold for number of colonoscopies performed under attending supervision may be needed to achieve adequate ADR during fellowship prior to independent practice.

  9. The Detection and Correction of Bias in Student Ratings of Instruction.

    Science.gov (United States)

    Haladyna, Thomas; Hess, Robert K.

    1994-01-01

    A Rasch model was used to detect and correct bias in Likert rating scales used to assess student perceptions of college teaching, using a database of ratings. Statistical corrections were significant, supporting the model's potential utility. Recommendations are made for a theoretical rationale and further research on the model. (Author/MSE)

  10. Estimating detection rates for the LIGO-Virgo search for gravitational-wave burst counterparts to gamma-ray bursts using inferred local GRB rates

    International Nuclear Information System (INIS)

    Leonor, I; Frey, R; Sutton, P J; Jones, G; Marka, S; Marka, Z

    2009-01-01

    One of the ongoing searches performed using the LIGO-Virgo network of gravitational-wave interferometers is the search for gravitational-wave burst (GWB) counterparts to gamma-ray bursts (GRBs). This type of analysis makes use of GRB time and position information from gamma-ray satellite detectors to trigger the GWB search, and the GWB detection rates possible for such an analysis thus strongly depend on the GRB detection efficiencies of the satellite detectors. Using local GRB rate densities inferred from observations which are found in the science literature, we calculate estimates of the GWB detection rates for different configurations of the LIGO-Virgo network for this type of analysis.

  11. Fusion of Heterogeneous Intrusion Detection Systems for Network Attack Detection

    Directory of Open Access Journals (Sweden)

    Jayakumar Kaliappan

    2015-01-01

    Full Text Available An intrusion detection system (IDS helps to identify different types of attacks in general, and the detection rate will be higher for some specific category of attacks. This paper is designed on the idea that each IDS is efficient in detecting a specific type of attack. In proposed Multiple IDS Unit (MIU, there are five IDS units, and each IDS follows a unique algorithm to detect attacks. The feature selection is done with the help of genetic algorithm. The selected features of the input traffic are passed on to the MIU for processing. The decision from each IDS is termed as local decision. The fusion unit inside the MIU processes all the local decisions with the help of majority voting rule and makes the final decision. The proposed system shows a very good improvement in detection rate and reduces the false alarm rate.

  12. Adaptive heart rate-based epileptic seizure detection using real-time user feedback

    DEFF Research Database (Denmark)

    De Cooman, Thomas; Kjær, Troels Wesenberg; Van Huffel, Sabine

    2017-01-01

    Automated seizure detection in a home environment has been of increased interest the last couple of decades. Heart rate-based seizure detection is a way to detect temporal lobe epilepsy seizures at home, but patient-independent algorithms showed to be insufficiently accurate due to the high patient...... with incorrect user feedback, making it ideal for implementation in a home environment for a seizure warning system....

  13. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    OpenAIRE

    Qing-Hui WANG; Fang MU; Li-Feng WEI

    2014-01-01

    This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or conce...

  14. Strain rate effects in nuclear steels at room and higher temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Solomos, G. E-mail: george.solomos@jrc.it; Albertini, C.; Labibes, K.; Pizzinato, V.; Viaccoz, B

    2004-04-01

    An investigation of strain rate, temperature and size effects in three nuclear steels has been conducted. The materials are: ferritic steel 20MnMoNi55 (vessel head), austenitic steel X6CrNiNb1810 (upper internal structure), and ferritic steel 26NiCrMo146 (bolting). Smooth cylindrical tensile specimens of three sizes have been tested at strain rates from 0.001 to 300 s{sup -1}, at room and elevated temperatures (400-600 deg. C). Full stress-strain diagrams have been obtained, and additional parameters have been calculated based on them. The results demonstrate a clear influence of temperature, which amounts into reducing substantially mechanical strengths with respect to RT conditions. The effect of strain rate is also shown. It is observed that at RT the strain rate effect causes up shifting of the flow stress curves, whereas at the higher temperatures a mild downshifting of the flow curves is manifested. Size effect tendencies have also been observed. Some implications when assessing the pressure vessel structural integrity under severe accident conditions are considered.

  15. Using a higher criticism statistic to detect modest effects in a genome-wide study of rheumatoid arthritis

    Science.gov (United States)

    2009-01-01

    In high-dimensional studies such as genome-wide association studies, the correction for multiple testing in order to control total type I error results in decreased power to detect modest effects. We present a new analytical approach based on the higher criticism statistic that allows identification of the presence of modest effects. We apply our method to the genome-wide study of rheumatoid arthritis provided in the Genetic Analysis Workshop 16 Problem 1 data set. There is evidence for unknown bias in this study that could be explained by the presence of undetected modest effects. We compared the asymptotic and empirical thresholds for the higher criticism statistic. Using the asymptotic threshold we detected the presence of modest effects genome-wide. We also detected modest effects using 90th percentile of the empirical null distribution as a threshold; however, there is no such evidence when the 95th and 99th percentiles were used. While the higher criticism method suggests that there is some evidence for modest effects, interpreting individual single-nucleotide polymorphisms with significant higher criticism statistics is of undermined value. The goal of higher criticism is to alert the researcher that genetic effects remain to be discovered and to promote the use of more targeted and powerful studies to detect the remaining effects. PMID:20018032

  16. Why do younger women have higher breast cancer recurrence rates after breast-conserving surgery?

    International Nuclear Information System (INIS)

    Nishimura, Reiki; Matsuda, Masakazu; Miyayama, Haruhiko; Okazaki, Shinji; Kai, Chiharu; Ozaki, N.

    2003-01-01

    Preventing breast cancer recurrence after breast-conserving surgery is an important issue. The main factors contributing to such recurrence are positive margins, absence of radiotherapy and young age. To investigate the clinical significance of age in breast-conserving surgery, we examined the relationship between clinicopathological findings or outcome and age, especially young age. The cases were divided into three groups by age; 35 years old or less, 36-50y.o. and 51y.o. or higher. Between April 1989 and March 2003, 743 patients were treated with breast-conserving surgery. There were 49 patients aged 35 years old or less (6.6%). Younger age significantly correlated with positive surgical margin, lymph node metastases, higher proliferative activity, negative estrogen receptor (ER) or progesterone receptor (PgR), larger tumor size, and shorter nipple-tumor distances. Although younger patients had a higher recurrence rate irrespective of radiotherapy, margin status had an impact on recurrence rate. Thus, the reason young age was a significant factor for breast recurrence after breast-conserving surgery was that young patients frequently had numerous risk factors such as positive margin, higher proliferative activity, positive nodes, negative ER/PgR and larger tumor. However, negative surgical margins could reduce recurrence rates even in young women. These results suggest that more suitable criteria and strategies may be needed for young patients with breast cancer. (author)

  17. Will ageing lead to a higher real exchange rate for the Netherlands?

    NARCIS (Netherlands)

    van Ewijk, C.; Volkerink, M.

    2012-01-01

    Long term projections for the Netherlands indicate that demand for nontradables—e.g. health care services—will increase relative to supply due to population ageing. If this leads to higher future real exchanges rates this will erode the return of the savings currently made to prepare for ageing.

  18. Will ageing lead to a higher real exchange rate for the Netherlands?

    NARCIS (Netherlands)

    van Ewijk, C.; Volkerink, M.

    2011-01-01

    Long-term projections for the Netherlands indicate that demand for nontradables - e.g. health care services - will increase relative to supply due to population ageing. If this leads to higher future real exchanges rates this will erode the return of the savings currently made to prepare for ageing.

  19. Opportunistic mammography screening provides effective detection rates in a limited resource healthcare system.

    Science.gov (United States)

    Teh, Yew-Ching; Tan, Gie-Hooi; Taib, Nur Aishah; Rahmat, Kartini; Westerhout, Caroline Judy; Fadzli, Farhana; See, Mee-Hoong; Jamaris, Suniza; Yip, Cheng-Har

    2015-05-15

    Breast cancer is the leading cause of cancer deaths in women world-wide. In low and middle income countries, where there are no population-based mammographic screening programmes, late presentation is common, and because of inadequate access to optimal treatment, survival rates are poor. Mammographic screening is well-studied in high-income countries in western populations, and because it has been shown to reduce breast cancer mortality, it has become part of the healthcare systems in such countries. However the performance of mammographic screening in a developing country is largely unknown. This study aims to evaluate the performance of mammographic screening in Malaysia, a middle income country, and to compare the stage and surgical treatment of screen-detected and symptomatic breast cancer. A retrospective review of 2510 mammograms performed from Jan to Dec 2010 in a tertiary medical centre is carried out. The three groups identified are the routine (opportunistic) screening group, the targeted (high risk) screening group and the diagnostic group. The performance indicators of each group is calculated, and stage at presentation and treatment between the screening and diagnostic group is analyzed. The cancer detection rate in the opportunistic screening group, targeted screening group, and the symptomatic group is 0.5 %, 1.25 % and 26 % respectively. The proportion of ductal carcinoma in situ is 23.1 % in the two screening groups compared to only 2.5 % in the diagnostic group. Among the opportunistic screening group, the cancer detection rate was 0.2 % in women below 50 years old compared to 0.65 % in women 50 years and above. The performance indicators are within international standards. Early-staged breast cancer (Stage 0-2) were 84.6 % in the screening groups compared to 61.1 % in the diagnostic group. From the results, in a setting with resource constraints, targeted screening of high risk individuals will give a higher yield, and if more resources are

  20. A Comparative Study of Data Mining Algorithms for High Detection Rate in Intrusion Detection System

    Directory of Open Access Journals (Sweden)

    Nabeela Ashraf

    2018-01-01

    Full Text Available Due to the fast growth and tradition of the internet over the last decades, the network security problems are increasing vigorously. Humans can not handle the speed of processes and the huge amount of data required to handle network anomalies. Therefore, it needs substantial automation in both speed and accuracy. Intrusion Detection System is one of the approaches to recognize illegal access and rare attacks to secure networks. In this proposed paper, Naive Bayes, J48 and Random Forest classifiers are compared to compute the detection rate and accuracy of IDS. For experiments, the KDD_NSL dataset is used.

  1. Non-contact detection of cardiac rate based on visible light imaging device

    Science.gov (United States)

    Zhu, Huishi; Zhao, Yuejin; Dong, Liquan

    2012-10-01

    We have developed a non-contact method to detect human cardiac rate at a distance. This detection is based on the general lighting condition. Using the video signal of human face region captured by webcam, we acquire the cardiac rate based on the PhotoPlethysmoGraphy theory. In this paper, the cardiac rate detecting method is mainly in view of the blood's different absorptivities of the lights various wavelengths. Firstly, we discompose the video signal into RGB three color signal channels and choose the face region as region of interest to take average gray value. Then, we draw three gray-mean curves on each color channel with time as variable. When the imaging device has good fidelity of color, the green channel signal shows the PhotoPlethysmoGraphy information most clearly. But the red and blue channel signals can provide more other physiological information on the account of their light absorptive characteristics of blood. We divide red channel signal by green channel signal to acquire the pulse wave. With the passband from 0.67Hz to 3Hz as a filter of the pulse wave signal and the frequency spectrum superimposed algorithm, we design frequency extracted algorithm to achieve the cardiac rate. Finally, we experiment with 30 volunteers, containing different genders and different ages. The results of the experiments are all relatively agreeable. The difference is about 2bmp. Through the experiment, we deduce that the PhotoPlethysmoGraphy theory based on visible light can also be used to detect other physiological information.

  2. Mutation induction in cultured human cells after low-dose and low-dose-rate γ-ray irradiation. Detection by LOH analysis

    International Nuclear Information System (INIS)

    Umebayashi, Yukihiro; Iwaki, Masaya; Yatagai, Fumio; Honma, Masamitsu; Suzuki, Masao; Suzuki, Hiromi; Shimazu, Toru; Ishioka, Noriaki

    2007-01-01

    To study the genetic effects of low-doses and low-dose-rate ionizing radiation (IR), human lymphoblastoid TK6 cells were exposed to 30 mGy of γ-rays at a dose-rate of 1.2 mGy/hr. The frequency of early mutations (EMs) in the thymidine kinase (TK) gene locus was determined to be 1.7 x 10 -6 , or 1.9-fold higher than the level seen in unirradiated controls. These mutations were analyzed with a loss of heterozygosity (LOH) detection system, a methodology which has been shown to be sensitive to the effects of radiation. Among the 15 EMs observed after IR exposure, 8 were small interstitial-deletion events restricted to the TK gene locus. However, this specific type of event was not found in unirradiated controls. Although these results were observed under the limited conditions, they strongly suggest that the LOH detection system can be used for estimating the genetic effects of a low-dose IR exposure delivered at a low-dose-rate. (author)

  3. Cost and detection rate of glaucoma screening with imaging devices in a primary care center

    Directory of Open Access Journals (Sweden)

    Anton A

    2017-02-01

    Full Text Available Alfonso Anton,1–4 Monica Fallon,3,5 Francesc Cots,2 María A Sebastian,6 Antonio Morilla-Grasa,4 Sergi Mojal,3 Xavier Castells2 1Medicine School, Universidad Internacional de Cataluña, 2Servei d’Estudies, Parc de Salut Mar, 3Instituto Hospital del Mar de Investigaciones Médicas (IMIM, 4Glaucoma Department, Instituto Catalán de Retina (ICR, 5Universidad Autónoma de Barcelona, 6Centro de Atención Primaria Larrard, Barcelona, Spain Purpose: To analyze the cost and detection rate of a screening program for detecting glaucoma with imaging devices. Materials and methods: In this cross-sectional study, a glaucoma screening program was applied in a population-based sample randomly selected from a population of 23,527. Screening targeted the population at risk of glaucoma. Examinations included optic disk tomography (Heidelberg retina tomograph [HRT], nerve fiber analysis, and tonometry. Subjects who met at least 2 of 3 endpoints (HRT outside normal limits, nerve fiber index ≥30, or tonometry ≥21 mmHg were referred for glaucoma consultation. The currently established (“conventional” detection method was evaluated by recording data from primary care and ophthalmic consultations in the same population. The direct costs of screening and conventional detection were calculated by adding the unit costs generated during the diagnostic process. The detection rate of new glaucoma cases was assessed. Results: The screening program evaluated 414 subjects; 32 cases were referred for glaucoma consultation, 7 had glaucoma, and 10 had probable glaucoma. The current detection method assessed 677 glaucoma suspects in the population, of whom 29 were diagnosed with glaucoma or probable glaucoma. Glaucoma screening and the conventional detection method had detection rates of 4.1% and 3.1%, respectively, and the cost per case detected was 1,410 and 1,435€, respectively. The cost of screening 1 million inhabitants would be 5.1 million euros and would allow

  4. EUROCAT website data on prenatal detection rates of congenital anomalies

    DEFF Research Database (Denmark)

    Garne, Ester; Dolk, Helen; Loane, Maria

    2010-01-01

    The EUROCAT website www.eurocat-network.eu publishes prenatal detection rates for major congenital anomalies using data from European population-based congenital anomaly registers, covering 28% of the EU population as well as non-EU countries. Data are updated annually. This information can be us...

  5. EUROCAT website data on prenatal detection rates of congenital anomalies

    NARCIS (Netherlands)

    Garne, Ester; Dolk, Helen; Loane, Maria; Boyd, Patricia A.

    2010-01-01

    The EUROCAT website www.eurocat-network.eu publishes prenatal detection rates for major congenital anomalies using data from European population-based congenital anomaly registers, covering 28% of the EU population as well as non-EU countries. Data are updated annually. This information can be

  6. Direct SUSY dark matter detection-theoretical rates due to the spin

    International Nuclear Information System (INIS)

    Vergados, J D

    2004-01-01

    The recent WMAP data have confirmed that exotic dark matter together with the vacuum energy (cosmological constant) dominate in the flat Universe. Thus direct dark matter detection, consisting of detecting the recoiling nucleus, is central to particle physics and cosmology. Supersymmetry provides a natural dark matter candidate, the lightest supersymmetric particle (LSP). The relevant cross sections arise out of two mechanisms: (i) the coherent mode, due to the scalar interaction and (ii) the spin contribution arising from the axial current. In this paper we will focus on the spin contribution, which is expected to dominate for light targets. For both modes it is possible to obtain detectable rates, but in most models the expected rates are much lower than the present experimental goals. So one should exploit two characteristic signatures of the reaction, namely the modulation effect and in directional experiments the correlation of the event rates with the sun's motion. In standard non-directional experiments the modulation is small, less than 2 per cent. In the case of the directional event rates we would like to suggest that the experiments exploit two features of the process, which are essentially independent of the SUSY model employed, namely: (1) the forward-backward asymmetry, with respect to the sun's direction of motion, is very large and (2) the modulation is much larger, especially if the observation is made in a plane perpendicular to the sun's velocity. In this case the difference between maximum and minimum can be larger than 40 per cent and the phase of the earth at the maximum is direction dependent

  7. Drowsiness detection using heart rate variability.

    Science.gov (United States)

    Vicente, José; Laguna, Pablo; Bartra, Ariadna; Bailón, Raquel

    2016-06-01

    It is estimated that 10-30 % of road fatalities are related to drowsy driving. Driver's drowsiness detection based on biological and vehicle signals is being studied in preventive car safety. Autonomous nervous system activity, which can be measured noninvasively from the heart rate variability (HRV) signal obtained from surface electrocardiogram, presents alterations during stress, extreme fatigue and drowsiness episodes. We hypothesized that these alterations manifest on HRV and thus could be used to detect driver's drowsiness. We analyzed three driving databases in which drivers presented different sleep-deprivation levels, and in which each driving minute was annotated as drowsy or awake. We developed two different drowsiness detectors based on HRV. While the drowsiness episodes detector assessed each minute of driving as "awake" or "drowsy" with seven HRV derived features (positive predictive value 0.96, sensitivity 0.59, specificity 0.98 on 3475 min of driving), the sleep-deprivation detector discerned if a driver was suitable for driving or not, at driving onset, as function of his sleep-deprivation state. Sleep-deprivation state was estimated from the first three minutes of driving using only one HRV feature (positive predictive value 0.80, sensitivity 0.62, specificity 0.88 on 30 drivers). Incorporating drowsiness assessment based on HRV signal may add significant improvements to existing car safety systems.

  8. Higher Rate of Tuberculosis in Second Generation Migrants Compared to Native Residents in a Metropolitan Setting in Western Europe

    Science.gov (United States)

    Marx, Florian M.; Fiebig, Lena; Hauer, Barbara; Brodhun, Bonita; Glaser-Paschke, Gisela; Haas, Walter

    2015-01-01

    Background In Western Europe, migrants constitute an important risk group for tuberculosis, but little is known about successive generations of migrants. We aimed to characterize migration among tuberculosis cases in Berlin and to estimate annual rates of tuberculosis in two subsequent migrant generations. We hypothesized that second generation migrants born in Germany are at higher risk of tuberculosis compared to native (non-migrant) residents. Methods A prospective cross-sectional study was conducted. All tuberculosis cases reported to health authorities in Berlin between 11/2010 and 10/2011 were eligible. Interviews were conducted using a structured questionnaire including demographic data, migration history of patients and their parents, and language use. Tuberculosis rates were estimated using 2011 census data. Results Of 314 tuberculosis cases reported, 154 (49.0%) participated. Of these, 81 (52.6%) were first-, 14 (9.1%) were second generation migrants, and 59 (38.3%) were native residents. The tuberculosis rate per 100,000 individuals was 28.3 (95CI: 24.0–32.6) in first-, 10.2 (95%CI: 6.1–16.6) in second generation migrants, and 4.6 (95%CI: 3.7–5.6) in native residents. When combining information from the standard notification variables country of birth and citizenship, the sensitivity to detect second generation migration was 28.6%. Conclusions There is a higher rate of tuberculosis among second generation migrants compared to native residents in Berlin. This may be explained by presumably frequent contact and transmission within migrant populations. Second generation migration is insufficiently captured by the surveillance variables country of birth and citizenship. Surveillance systems in Western Europe should allow for quantifying the tuberculosis burden in this important risk group. PMID:26061733

  9. Multi-disciplinary team for early gastric cancer diagnosis improves the detection rate of early gastric cancer.

    Science.gov (United States)

    Di, Lianjun; Wu, Huichao; Zhu, Rong; Li, Youfeng; Wu, Xinglong; Xie, Rui; Li, Hongping; Wang, Haibo; Zhang, Hua; Xiao, Hong; Chen, Hui; Zhen, Hong; Zhao, Kui; Yang, Xuefeng; Xie, Ming; Tuo, Bigung

    2017-12-06

    Gastric cancer is a frequent malignant tumor worldwide and its early detection is crucial for curing the disease and enhancing patients' survival rate. This study aimed to assess whether the multi-disciplinary team (MDT) can improve the detection rate of early gastric cancer (EGC). The detection rate of EGC at the Digestive Endoscopy Center, Affiliated Hospital, Zunyi Medical College, China between September 2013 and September 2015 was analyzed. MDT for the diagnosis of EGC in the hospital was established in September 2014. The study was divided into 2 time periods: September 1, 2013 to August 31, 2014 (period 1) and September 1, 2014 to September 1, 2015 (period 2). A total of 60,800 patients' gastroscopies were performed during the two years. 61 of these patients (0.1%) were diagnosed as EGC, accounting for 16.44% (61/371) of total patients with gastric cancer. The EGC detection rate before MDT (period 1) was 0.05% (16/29403), accounting for 9.09% (16/176) of total patients with gastric cancer during this period. In comparison, the EGC detection rate during MDT (period 2) was 0.15% (45/31397), accounting for 23% (45/195) of total patients with gastric cancer during this period (P cooperation with Department of Pathology (OR = 10.1, 95% CI 2.39-43.3, P < 0.05). MDT could improve the endoscopic detection rate of EGC.

  10. A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features.

    Science.gov (United States)

    Dao, Duy; Salehizadeh, S M A; Noh, Yeonsik; Chong, Jo Woon; Cho, Chae Ho; McManus, Dave; Darling, Chad E; Mendelson, Yitzhak; Chon, Ki H

    2017-09-01

    recently developed in our laboratory. The proposed TifMA algorithm consistently provided higher detection rates than the other three methods, with accuracies greater than 95% for all data. Moreover, our algorithm was able to pinpoint the start and end times of the MNA with an error of less than 1 s in duration, whereas the next-best algorithm had a detection error of more than 2.2 s. The final, most challenging, dataset was collected to verify the performance of the algorithm in discriminating between corrupted data that were usable for accurate HR estimations and data that were nonusable. It was found that on average 48% of the data segments were found to have MNA, and of these, 38% could be used to provide reliable HR estimation.

  11. HPV detection rate in saliva may depend on the immune system efficiency.

    Science.gov (United States)

    Adamopoulou, Maria; Vairaktaris, Eleftherios; Panis, Vassilis; Nkenke, Emeka; Neukam, Friedreich W; Yapijakis, Christos

    2008-01-01

    Human papilloma virus (HPV) has been established as a major etiological factor of anogenital cancer. In addition, HPV has also been implicated in oral carcinogenesis but its detection rates appear to be highly variable, depending on the patient population tested, the molecular methodology used, as well as the type of oral specimen investigated. For example, saliva is an oral fluid that may play a role in HPV transmission, although the detection rates of the virus are lower than tissue. Recent evidence has indicated that HPV-related pathology is increased in the oral cavity of human immunodeficiency virus (HIV)-positive individuals. In order to investigate whether the presence of different HPV types in saliva depends on immune system efficiency, oral fluid samples of patients with oral cancer and without any known immune deficiency were compared with those of HIV-positive individuals. Saliva samples were collected from 68 patients with oral squamous cell carcinoma and 34 HIV seropositive individuals. HPV DNA sequences were detected by L1 concensus polymerase chain reaction (PCR), followed by restriction fragment length polymorphism (RFLP) analysis and DNA sequencing for HPV typing. HPV DNA was detected in 7/68 (10.3%) of the oral cancer patients and in 12/34 (35.3%) of the HIV-positive individuals, a highly significant difference (p = 0.006; odds ratio 4.753; 95% confidence interval 1.698-13.271). Among HPV-positive samples, the prevalence of HPV types associated with high oncogenic risk was similar in oral cancer and HIV-positive cases (71.4% and 66.7%, respectively). In both groups, the most common HPV type was high-risk 16 (50% and 42.8%, respectively). Although a similar pattern of HPV high-risk types was detected in oral cancer and HIV-positive cases, the quantitative detection of HPV in saliva significantly depended on immune system efficiency. Furthermore, the significantly increased detection rates of HPV in saliva of HIV-positive individuals may be

  12. Detecting subsurface fluid leaks in real-time using injection and production rates

    Science.gov (United States)

    Singh, Harpreet; Huerta, Nicolas J.

    2017-12-01

    CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to

  13. Comparison of detectable bleeding rates of radiopharmaceuticals for localization of gastrointestinal bleeding in sheep using a closed system

    International Nuclear Information System (INIS)

    Owunwanne, A.; Sadek, S.; Yacoub, T.; Awdeh, M.; Abdel-Dayem, H.M.; Al-Wafai, I.; Vallgren, S.

    1989-01-01

    The closed experimental animal model system was used to compare the detectable gastrointestinal (GI) bleeding rates of 99m Tc-DTPA, 99m Tc-RBCs and 99m Tc tin colloid in sheep. The three radiopharmaceuticals were used to detect the upper GI bleeding sites at rates of 0.57 and 0.25 ml/min. At the lower bleeding rate of 0.1 ml/min, both 99m Tc-DTPA and 99m Tc-RBCs were successful in detecting the bleeding site. At the lowest rate of 0.07 ml/min only 99m Tc-DTPA was successful in detecting the bleeding site. The results indicate that 99m Tc-DTPA is the most useful 99m Tc radiopharmaceutical for detecting the upper GI bleeding site at the slowest bleeding rate studied. (orig.) [de

  14. Factors influencing variation in physician adenoma detection rates: a theory-based approach for performance improvement.

    Science.gov (United States)

    Atkins, Louise; Hunkeler, Enid M; Jensen, Christopher D; Michie, Susan; Lee, Jeffrey K; Doubeni, Chyke A; Zauber, Ann G; Levin, Theodore R; Quinn, Virginia P; Corley, Douglas A

    2016-03-01

    Interventions to improve physician adenoma detection rates for colonoscopy have generally not been successful, and there are little data on the factors contributing to variation that may be appropriate targets for intervention. We sought to identify factors that may influence variation in detection rates by using theory-based tools for understanding behavior. We separately studied gastroenterologists and endoscopy nurses at 3 Kaiser Permanente Northern California medical centers to identify potentially modifiable factors relevant to physician adenoma detection rate variability by using structured group interviews (focus groups) and theory-based tools for understanding behavior and eliciting behavior change: the Capability, Opportunity, and Motivation behavior model; the Theoretical Domains Framework; and the Behavior Change Wheel. Nine factors potentially associated with adenoma detection rate variability were identified, including 6 related to capability (uncertainty about which types of polyps to remove, style of endoscopy team leadership, compromised ability to focus during an examination due to distractions, examination technique during withdrawal, difficulty detecting certain types of adenomas, and examiner fatigue and pain), 2 related to opportunity (perceived pressure due to the number of examinations expected per shift and social pressure to finish examinations before scheduled breaks or the end of a shift), and 1 related to motivation (valuing a meticulous examination as the top priority). Examples of potential intervention strategies are provided. By using theory-based tools, this study identified several novel and potentially modifiable factors relating to capability, opportunity, and motivation that may contribute to adenoma detection rate variability and be appropriate targets for future intervention trials. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Device to detect the presence of a pure signal in a discrete noisy signal measured at an average rate of constant noise with a probability of false detection lower than one predeterminated

    International Nuclear Information System (INIS)

    Poussier, E.; Rambaut, M.

    1986-01-01

    Detection consists of a measurement of a counting rate. A probability of wrong detection is associated with this counting rate and with an average estimated rate of noise. Detection consists also in comparing the wrong detection probability to a predeterminated rate of wrong detection. The comparison can use tabulated values. Application is made to corpuscule radiation detection [fr

  16. Comparison of detectable bleeding rates of radiopharmaceuticals for localization of gastrointestinal bleeding in sheep using a closed system

    Energy Technology Data Exchange (ETDEWEB)

    Owunwanne, A.; Sadek, S.; Yacoub, T.; Awdeh, M.; Abdel-Dayem, H.M. (Kuwait Univ. (Kuwait). Dept. of Nuclear Medicine); Al-Wafai, I.; Vallgren, S. (Kuwait Univ. (Kuwait). Dept. of Surgery)

    1989-06-01

    The closed experimental animal model system was used to compare the detectable gastrointestinal (GI) bleeding rates of {sup 99m}Tc-DTPA, {sup 99m}Tc-RBCs and {sup 99m}Tc tin colloid in sheep. The three radiopharmaceuticals were used to detect the upper GI bleeding sites at rates of 0.57 and 0.25 ml/min. At the lower bleeding rate of 0.1 ml/min, both {sup 99m}Tc-DTPA and {sup 99m}Tc-RBCs were successful in detecting the bleeding site. At the lowest rate of 0.07 ml/min only {sup 99m}Tc-DTPA was successful in detecting the bleeding site. The results indicate that {sup 99m}Tc-DTPA is the most useful {sup 99m}Tc radiopharmaceutical for detecting the upper GI bleeding site at the slowest bleeding rate studied. (orig.).

  17. Factors influencing cerebrospinal fluid and plasma HIV-1 RNA detection rate in patients with and without opportunistic neurological disease during the HAART era

    Directory of Open Access Journals (Sweden)

    Aleixo Agdemir W

    2007-12-01

    Full Text Available Abstract Background In the central nervous system, HIV replication can occur relatively independent of systemic infection, and intrathecal replication of HIV-1 has been observed in patients with HIV-related and opportunistic neurological diseases. The clinical usefulness of HIV-1 RNA detection in the cerebrospinal fluid (CSF of patients with opportunistic neurological diseases, or the effect of opportunistic diseases on CSF HIV levels in patients under HAART has not been well defined. We quantified CSF and plasma viral load in HIV-infected patients with and without different active opportunistic neurological diseases, determined the characteristics that led to a higher detection rate of HIV RNA in CSF, and compared these two compartments. Methods A prospective study was conducted on 90 HIV-infected patients submitted to lumbar puncture as part of a work-up for suspected neurological disease. Seventy-one patients had active neurological diseases while the remaining 19 did not. Results HIV-1 RNA was quantified in 90 CSF and 70 plasma samples. The HIV-1 RNA detection rate in CSF was higher in patients with neurological diseases, in those with a CD4 count lower than 200 cells/mm3, and in those not receiving antiretroviral therapy, as well as in patients with detectable plasma HIV-1 RNA. Median viral load was lower in CSF than in plasma in the total population, in patients without neurological diseases, and in patients with toxoplasmic encephalitis, while no significant difference between the two compartments was observed for patients with cryptococcal meningitis and HIV-associated dementia. CSF viral load was lower in patients with cryptococcal meningitis and neurotoxoplasmosis under HAART than in those not receiving HAART. Conclusion Detection of HIV-1 RNA in CSF was more frequent in patients with neurological disease, a CD4 count lower than 200 cells/mm3 and detectable plasma HIV-1. Median HIV-1 RNA levels were generally lower in CSF than in

  18. Does the Economic Crisis Have an Influence on the Higher Education Dropout Rate?

    Science.gov (United States)

    Leão Fernandes, Graça; Chagas Lopes, Margarida

    2016-01-01

    This research aims to identify the effects of the economic crisis on higher education (HE) dropout rates at Lisbon School of Economics and Management (ISEG)--Universidade de Lisboa, after having controlled for individual characteristics, family background, High School and HE trajectories. Our main hypothesis is that the economic crisis induces…

  19. Calm Merino ewes have a higher ovulation rate and more multiple pregnancies than nervous ewes.

    Science.gov (United States)

    van Lier, E; Hart, K W; Viñoles, C; Paganoni, B; Blache, D

    2017-07-01

    In 1990, two selection lines of Merino sheep were established for low and high behavioural reactivity (calm and nervous temperament) at the University of Western Australia. Breeding records consistently showed that calm ewes weaned 10% to 19% more lambs than the nervous ewes. We hypothesise that calm ewes could have a higher ovulation rate than nervous ewes and/or calm ewes could have a lower rate of embryo mortality than nervous ewes. We tested these hypotheses by comparing the ovulation rate and the rate of embryo mortality between the calm and nervous lines before and after synchronisation and artificial insemination. Merino ewes from the temperament selection lines (calm, n=100; nervous, n=100) were synchronised (early breeding season) for artificial insemination (day 0) (intravaginal sponges containing fluogestone acetate and eCG immediately after sponge withdrawal). On day-17 and 11 ovarian cyclicity and corpora lutea, and on days 30 and 74 pregnancies and embryos/foetuses were determined by ultrasound. Progesterone, insulin and leptin concentrations were determined in blood plasma samples from days 5, 12 and 17. Ovarian cyclicity before and after oestrus synchronisation did not differ between the lines, but ovulation rate did (day-17: calm 1.63; nervous 1.26; Pewes was higher than on day-17. Loss of embryos by day 30 was high (calm: 71/150; nervous: 68/130); but nervous ewes had a lower proportion (15/47) of multiple pregnancies compared with calm ewes (30/46; Pewes had higher insulin (32.0 pmol/l±1.17 SEM; P=0.013) and lower leptin (1.18 μg/l±0.04 SEM; P=0.002) concentrations than calm ewes (insulin: 27.8 pmol/l±1.17 SEM; leptin: 1.35 μg/l±0.04 SEM). The differences in reproductive outcomes between the calm and nervous ewes were mainly due to a higher ovulation rate in calm ewes. We suggest that reproduction in nervous ewes is compromised by factors leading up to ovulation and conception, or the uterine environment during early pregnancy, that reflect

  20. Hotspot detection using image pattern recognition based on higher-order local auto-correlation

    Science.gov (United States)

    Maeda, Shimon; Matsunawa, Tetsuaki; Ogawa, Ryuji; Ichikawa, Hirotaka; Takahata, Kazuhiro; Miyairi, Masahiro; Kotani, Toshiya; Nojima, Shigeki; Tanaka, Satoshi; Nakagawa, Kei; Saito, Tamaki; Mimotogi, Shoji; Inoue, Soichi; Nosato, Hirokazu; Sakanashi, Hidenori; Kobayashi, Takumi; Murakawa, Masahiro; Higuchi, Tetsuya; Takahashi, Eiichi; Otsu, Nobuyuki

    2011-04-01

    Below 40nm design node, systematic variation due to lithography must be taken into consideration during the early stage of design. So far, litho-aware design using lithography simulation models has been widely applied to assure that designs are printed on silicon without any error. However, the lithography simulation approach is very time consuming, and under time-to-market pressure, repetitive redesign by this approach may result in the missing of the market window. This paper proposes a fast hotspot detection support method by flexible and intelligent vision system image pattern recognition based on Higher-Order Local Autocorrelation. Our method learns the geometrical properties of the given design data without any defects as normal patterns, and automatically detects the design patterns with hotspots from the test data as abnormal patterns. The Higher-Order Local Autocorrelation method can extract features from the graphic image of design pattern, and computational cost of the extraction is constant regardless of the number of design pattern polygons. This approach can reduce turnaround time (TAT) dramatically only on 1CPU, compared with the conventional simulation-based approach, and by distributed processing, this has proven to deliver linear scalability with each additional CPU.

  1. Continuous fermentation and in-situ reed separation of butyric acid for higher sugar consumption rate and productivity

    DEFF Research Database (Denmark)

    Baroi, George Nabin; Skiadas, Ioannis; Westermann, Peter

    that disconnection of the REED system resulted to much lower (48 and 83% for glucose and xylose, respectively) sugars consumption rates and consequently lower butyric acid production rates. It was also noticeable that continuous operation, even without the REED system, resulted to higher glucose consumption rates...

  2. Estimating diversification rates for higher taxa: BAMM can give problematic estimates of rates and rate shifts.

    Science.gov (United States)

    Meyer, Andreas L S; Wiens, John J

    2018-01-01

    Estimates of diversification rates are invaluable for many macroevolutionary studies. Recently, an approach called BAMM (Bayesian Analysis of Macro-evolutionary Mixtures) has become widely used for estimating diversification rates and rate shifts. At the same time, several articles have concluded that estimates of net diversification rates from the method-of-moments (MS) estimators are inaccurate. Yet, no studies have compared the ability of these two methods to accurately estimate clade diversification rates. Here, we use simulations to compare their performance. We found that BAMM yielded relatively weak relationships between true and estimated diversification rates. This occurred because BAMM underestimated the number of rates shifts across each tree, and assigned high rates to small clades with low rates. Errors in both speciation and extinction rates contributed to these errors, showing that using BAMM to estimate only speciation rates is also problematic. In contrast, the MS estimators (particularly using stem group ages), yielded stronger relationships between true and estimated diversification rates, by roughly twofold. Furthermore, the MS approach remained relatively accurate when diversification rates were heterogeneous within clades, despite the widespread assumption that it requires constant rates within clades. Overall, we caution that BAMM may be problematic for estimating diversification rates and rate shifts. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.

  3. Splenectomy is associated with higher infection and pneumonia rates among trauma laparotomy patients.

    Science.gov (United States)

    Fair, Kelly A; Connelly, Christopher R; Hart, Kyle D; Schreiber, Martin A; Watters, Jennifer M

    2017-05-01

    Splenectomy increases lifetime risk of thromboembolism (VTE) and is associated with long-term infectious complications, primarily, overwhelming post-splenectomy infection (OPSI). Our objective was to evaluate risk of VTE and infection at index hospitalization post-splenectomy. Retrospective review of all patients who received a laparotomy in the NTDB. Propensity score matching for splenectomy was performed, based on ISS, abdominal abbreviated injury score >3, GCS, sex and mechanism. Major complications, VTE, and infection rates were compared. Multiple logistic regression models were utilized to evaluate splenectomy-associated complications. 93,221 laparotomies were performed and 17% underwent splenectomy. Multiple logistic regression models did not demonstrate an association between splenectomy and major complications (OR 0.96, 95% CI 0.91-1.03, p = 0.25) or VTE (OR 1.05, 95% CI 0.96-1.14, p = 0.33). Splenectomy was independently associated with infection (OR 1.07, 95% CI 1.00-1.14, p = 0.045). Subgroup analysis of patients with infection demonstrated that splenectomy was most strongly associated with pneumonia (OR 1.41, 95% CI 1.26-1.57, p Splenectomy is not associated with higher overall complication or VTE rates during index hospitalization. However, splenectomy is associated with a higher rate of pneumonia. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Adaptive thresholding with inverted triangular area for real-time detection of the heart rate from photoplethysmogram traces on a smartphone.

    Science.gov (United States)

    Jiang, Wen Jun; Wittek, Peter; Zhao, Li; Gao, Shi Chao

    2014-01-01

    Photoplethysmogram (PPG) signals acquired by smartphone cameras are weaker than those acquired by dedicated pulse oximeters. Furthermore, the signals have lower sampling rates, have notches in the waveform and are more severely affected by baseline drift, leading to specific morphological characteristics. This paper introduces a new feature, the inverted triangular area, to address these specific characteristics. The new feature enables real-time adaptive waveform detection using an algorithm of linear time complexity. It can also recognize notches in the waveform and it is inherently robust to baseline drift. An implementation of the algorithm on Android is available for free download. We collected data from 24 volunteers and compared our algorithm in peak detection with two competing algorithms designed for PPG signals, Incremental-Merge Segmentation (IMS) and Adaptive Thresholding (ADT). A sensitivity of 98.0% and a positive predictive value of 98.8% were obtained, which were 7.7% higher than the IMS algorithm in sensitivity, and 8.3% higher than the ADT algorithm in positive predictive value. The experimental results confirmed the applicability of the proposed method.

  5. Higher Magnitude Cash Payments Improve Research Follow-up Rates Without Increasing Drug Use or Perceived Coercion

    Science.gov (United States)

    Festinger, David S.; Marlowe, Douglas B.; Dugosh, Karen L.; Croft, Jason R.; Arabia, Patricia L.

    2008-01-01

    In a prior study (Festinger et al., 2005) we found that neither the mode (cash vs. gift card) nor magnitude ($10, $40, or $70) of research follow-up payments increased rates of new drug use or perceptions of coercion. However, higher payments and payments in cash were associated with better follow-up attendance, reduced tracking efforts, and improved participant satisfaction with the study. The present study extended those findings to higher payment magnitudes. Participants from an urban outpatient substance abuse treatment program were randomly assigned to receive $70, $100, $130, or $160 in either cash or a gift card for completing a follow-up assessment at 6 months post-admission (n ≅ 50 per cell). Apart from the payment incentives, all participants received a standardized, minimal platform of follow-up efforts. Findings revealed that neither the magnitude nor mode of payment had a significant effect on new drug use or perceived coercion. Consistent with our previous findings, higher payments and cash payments resulted in significantly higher follow-up rates and fewer tracking calls. In addition participants receiving cash vs. gift cards were more likely to use their payments for essential, non-luxury purchases. Follow-up rates for participants receiving cash payments of $100, $130, and $160 approached or exceeded the FDA required minimum of 70% for studies to be considered in evaluations of new medications. This suggests that the use of higher magnitude payments and cash payments may be effective strategies for obtaining more representative follow-up samples without increasing new drug use or perceptions of coercion. PMID:18395365

  6. Minimum Symbol Error Rate Detection in Single-Input Multiple-Output Channels with Markov Noise

    DEFF Research Database (Denmark)

    Christensen, Lars P.B.

    2005-01-01

    Minimum symbol error rate detection in Single-Input Multiple- Output(SIMO) channels with Markov noise is presented. The special case of zero-mean Gauss-Markov noise is examined closer as it only requires knowledge of the second-order moments. In this special case, it is shown that optimal detection...

  7. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, John [Colorado State University, Department of Environmental and Radiological Health Sciences, Molecular and Radiological Biosciences Building, Colorado State University, Fort Collins, Colorado, 80523 (United States)

    2013-07-01

    We propose a radiation detection system which generates its own discrete sampling distribution based on past measurements of background. The advantage to this approach is that it can take into account variations in background with respect to time, location, energy spectra, detector-specific characteristics (i.e. different efficiencies at different count rates and energies), etc. This would therefore be a 'machine learning' approach, in which the algorithm updates and improves its characterization of background over time. The system would have a 'learning mode,' in which it measures and analyzes background count rates, and a 'detection mode,' in which it compares measurements from an unknown source against its unique background distribution. By characterizing and accounting for variations in the background, general purpose radiation detectors can be improved with little or no increase in cost. The statistical and computational techniques to perform this kind of analysis have already been developed. The necessary signal analysis can be accomplished using existing Bayesian algorithms which account for multiple channels, multiple detectors, and multiple time intervals. Furthermore, Bayesian machine-learning techniques have already been developed which, with trivial modifications, can generate appropriate decision thresholds based on the comparison of new measurements against a nonparametric sampling distribution. (authors)

  8. Human care system for heart-rate and human-movement trajectory in home and its application to detect mental disease

    Science.gov (United States)

    Hata, Yutaka; Kanazawa, Seigo; Endo, Maki; Tsuchiya, Naoki; Nakajima, Hiroshi

    2012-06-01

    This paper proposes a heart rate monitoring system for detecting autonomic nervous system by the heart rate variability using an air pressure sensor to diagnose mental disease. Moreover, we propose a human behavior monitoring system for detecting the human trajectory in home by an infrared camera. In day and night times, the human behavior monitoring system detects the human movement in home. The heart rate monitoring system detects the heart rate in bed in night time. The air pressure sensor consists of a rubber tube, cushion cover and pressure sensor, and it detects the heart rate by setting it to bed. It unconstraintly detects the RR-intervals; thereby the autonomic nervous system can be assessed. The autonomic nervous system analysis can examine the mental disease. While, the human behavior monitoring system obtains distance distribution image by an infrared camera. It classifies adult, child and the other object from distance distribution obtained by the camera, and records their trajectories. This behavior, i.e., trajectory in home, strongly corresponds to cognitive disorders. Thus, the total system can detect mental disease and cognitive disorders by uncontacted sensors to human body.

  9. A broad-application microchannel-plate detector system for advanced particle or photon detection tasks large area imaging, precise multi-hit timing information and high detection rate

    CERN Document Server

    Jagutzki, O; Mergel, V; Schmidt-Böcking, H; Spielberger, L; Spillmann, U; Ullmann-Pfleger, K

    2002-01-01

    New applications for single particle and photon detection in many fields require both large area imaging performance and precise time information on each detected particle. Moreover, a very high data acquisition rate is desirable for most applications and eventually the detection and imaging of more than one particle arriving within a microsecond is required. Commercial CCD systems lack the timing information whereas other electronic microchannel plate (MCP) read-out schemes usually suffer from a low acquisition rate and complicated and sometimes costly read-out electronics. We have designed and tested a complete imaging system consisting of an MCP position readout with helical wire delay-lines, single-unit amplifier box and PC-controlled time-to-digital converter (TDC) readout. The system is very flexible and can detect and analyse position and timing information at single particle rates beyond 1 MHz. Alternatively, multi-hit events can be collected and analysed at about 20 kHz rate. We discuss the advantage...

  10. Higher resting heart rate variability predicts skill in expressing some emotions.

    Science.gov (United States)

    Tuck, Natalie L; Grant, Rosemary C I; Sollers, John J; Booth, Roger J; Consedine, Nathan S

    2016-12-01

    Vagally mediated heart rate variability (vmHRV) is a measure of cardiac vagal tone, and is widely viewed as a physiological index of the capacity to regulate emotions. However, studies have not directly tested whether vmHRV is associated with the ability to facially express emotions. In extending prior work, the current report tested links between resting vmHRV and the objectively assessed ability to facially express emotions, hypothesizing that higher vmHRV would predict greater expressive skill. Eighty healthy women completed self-reported measures, before attending a laboratory session in which vmHRV and the ability to express six emotions in the face were assessed. A repeated measures analysis of variance revealed a marginal main effect for vmHRV on skill overall; individuals with higher resting vmHRV were only better able to deliberately facially express anger and interest. Findings suggest that differences in resting vmHRV are associated with the objectively assessed ability to facially express some, but not all, emotions, with potential implications for health and well-being. © 2016 Society for Psychophysiological Research.

  11. Wavelet-based higher-order neural networks for mine detection in thermal IR imagery

    Science.gov (United States)

    Baertlein, Brian A.; Liao, Wen-Jiao

    2000-08-01

    An image processing technique is described for the detection of miens in RI imagery. The proposed technique is based on a third-order neural network, which processes the output of a wavelet packet transform. The technique is inherently invariant to changes in signature position, rotation and scaling. The well-known memory limitations that arise with higher-order neural networks are addressed by (1) the data compression capabilities of wavelet packets, (2) protections of the image data into a space of similar triangles, and (3) quantization of that 'triangle space'. Using these techniques, image chips of size 28 by 28, which would require 0(109) neural net weights, are processed by a network having 0(102) weights. ROC curves are presented for mine detection in real and simulated imagery.

  12. Monochromatic Spectral Computed Tomography with Low Iodine Concentration Contrast Medium in a Rabbit VX2 Liver Model:: Investigation of Image Quality and Detection Rate.

    Science.gov (United States)

    Zhou, Yue; Xu, Han; Hou, Ping; Dong, Jun Q; Wang, Ming Y; Gao, Jian B

    2016-04-01

    This study aimed to validate the feasibility of using virtual monochromatic spectral computed tomography (CT) with isotonic low iodine concentration contrast medium for VX2 hepatic tumors. Sixty New Zealand white rabbits with implanted VX2 hepatic tumors underwent two-phase contrast-enhanced spectral CT imaging on the 14th day after tumor implantation. They were randomly divided into groups A, B, and C, with 20 rabbits each (group A: 270 mg I/mL, monochromatic spectral images; group B: 370 mg I/mL, conventional 120 kVp images, 100% filtered back projection [FBP]; group C: 270 mg I/mL, conventional 120 kVp images, 100% FBP). Group A was further divided into two subgroups (subgroup A1: 100% FBP; subgroup A2: 50% FBP + 50% adaptive statistical iterative reconstruction). Objective evaluation (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and image noise), subjective rating score (image noise score, anatomical details score, overall image quality score, and lesion conspicuity score), CT dose index volume, and dose length product were compared between groups during two-phase contrast enhancement. The detection rates of the four groups were calculated as percentages. Image noise (SNR and CNR) among the four groups was statistically significant (P noise in group A2 was lower than in group A1, but higher than that in groups B and C (P noise score of group A2 was higher than that of the other three groups. In terms of the anatomic details score, the overall image quality score, and the lesion conspicuity score, the images of group A2 were superior to that of groups A1 and C. For hepatic tumor diameters more than or equal to 1.0 cm and less than 3.0 cm, group A achieved a higher detection rate than groups B and C. The CT dose index volume, dose length product, and effective dose in group A were significantly lower than that in groups B and C (P noise, increase detection rate for small tumors, and decrease radiation dose and iodine load in

  13. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, M.C., E-mail: mburgmans@hotmail.com [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Too, C.W., E-mail: too.chow.wei@singhealth.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Kao, Y.H., E-mail: yung.h.kao@gmail.com [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Goh, A.S.W., E-mail: anthony.goh.s.w@sgh.com.sg [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Chow, P.K.H., E-mail: gsupc@singnet.com.sg [Department of General Surgery, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857 (Singapore); Department of Surgical Oncology, National Cancer Center Singapore, 11 Hospital Drive, Singapore 169610 (Singapore); Tan, B.S., E-mail: tan.bien.soo@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Tay, K.H., E-mail: tay.kiang.hiong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Lo, R.H.G., E-mail: richard.lo.h.g@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

    2012-12-15

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  14. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    International Nuclear Information System (INIS)

    Burgmans, M.C.; Too, C.W.; Kao, Y.H.; Goh, A.S.W.; Chow, P.K.H.; Tan, B.S.; Tay, K.H.; Lo, R.H.G.

    2012-01-01

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  15. Universal design of a microcontroller and IoT system to detect the heart rate

    Science.gov (United States)

    Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar

    2017-11-01

    Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).

  16. Shilling attack detection for recommender systems based on credibility of group users and rating time series.

    Science.gov (United States)

    Zhou, Wei; Wen, Junhao; Qu, Qiang; Zeng, Jun; Cheng, Tian

    2018-01-01

    Recommender systems are vulnerable to shilling attacks. Forged user-generated content data, such as user ratings and reviews, are used by attackers to manipulate recommendation rankings. Shilling attack detection in recommender systems is of great significance to maintain the fairness and sustainability of recommender systems. The current studies have problems in terms of the poor universality of algorithms, difficulty in selection of user profile attributes, and lack of an optimization mechanism. In this paper, a shilling behaviour detection structure based on abnormal group user findings and rating time series analysis is proposed. This paper adds to the current understanding in the field by studying the credibility evaluation model in-depth based on the rating prediction model to derive proximity-based predictions. A method for detecting suspicious ratings based on suspicious time windows and target item analysis is proposed. Suspicious rating time segments are determined by constructing a time series, and data streams of the rating items are examined and suspicious rating segments are checked. To analyse features of shilling attacks by a group user's credibility, an abnormal group user discovery method based on time series and time window is proposed. Standard testing datasets are used to verify the effect of the proposed method.

  17. Ways to be different: Foraging adaptations that facilitate higher intake rates in a northerly wintering shorebird compared with a low-latitude conspecific

    Science.gov (United States)

    Ruthrauff, Daniel R.; Dekinga, Anne; Gill, Robert E.; van Gils, Jan A.; Piersma, Theunis

    2015-01-01

    At what phenotypic level do closely related subspecies that live in different environments differ with respect to food detection, ingestion and processing? This question motivated an experimental study on rock sandpipers (Calidris ptilocnemis). The species' nonbreeding range spans 20 deg of latitude, the extremes of which are inhabited by two subspecies: C. p. ptilocnemis that winters primarily in upper Cook Inlet, Alaska (61°N) and C. p. tschuktschorum that overlaps slightly with C. p. ptilocnemis but whose range extends much farther south (∼40°N). In view of the strongly contrasting energetic demands of their distinct nonbreeding distributions, we conducted experiments to assess the behavioral, physiological and sensory aspects of foraging and we used the bivalve Macoma balthica for all trials. C. p. ptilocnemis consumed a wider range of prey sizes, had higher maximum rates of energy intake, processed shell waste at higher maximum rates and handled prey more quickly. Notably, however, the two subspecies did not differ in their abilities to find buried prey. The subspecies were similar in size and had equally sized gizzards, but the more northern ptilocnemis individuals were 10–14% heavier than their same-sex tschuktschorum counterparts. The higher body mass in ptilocnemis probably resulted from hypertrophy of digestive organs (e.g. intestine, liver) related to digestion and nutrient assimilation. Given the previously established equality of the metabolic capacities of the two subspecies, we propose that the high-latitude nonbreeding range of ptilocnemis rock sandpipers is primarily facilitated by digestive (i.e. physiological) aspects of their foraging ecology rather than behavioral or sensory aspects.

  18. Enhanced detection of gametocytes by magnetic deposition microscopy predicts higher potential for Plasmodium falciparum transmission

    Directory of Open Access Journals (Sweden)

    Zborowski Maciej

    2008-04-01

    Full Text Available Abstract Background Aggregated haemozoin crystals within malaria-infected erythrocytes confer susceptibility of parasitized cells to a magnetic field. Here the utility of this method for diagnosis of human malaria is evaluated in a malaria-endemic region of Papua New Guinea (PNG. Methods and findings Individuals with Plasmodium falciparum malaria symptoms (n = 55 provided samples for conventional blood smear (CBS and magnetic deposition microscopy (MDM diagnosis. Standard Giemsa staining and light microscopy was performed to evaluate all preparations. Plasmodium falciparum parasitaemia observed on MDM slides was consistently higher than parasitaemia observed by (CBS for ring (CBS = 2.6 vs. MDM = 3.4%; t-test P-value = 0.13, trophozoite (CBS = 0.5 vs. MDM = 1.6%; t-test P-value = 0.01, schizont (CBS = 0.003 vs. MDM = 0.1%; t-test P-value = 0.08 and gametocyte (CBS = 0.001 vs. MDM = 0.4%; t-test P-value = 0.0002 parasitaemias. Gametocyte prevalence determined by CBS compared to MDM increased from 7.3% to 45%, respectively. Conclusion MDM increased detection sensitivity of P. falciparum-infected, haemozoin-containing erythrocytes from infected humans while maintaining detection of ring-stage parasites. Gametocyte prevalence five-fold higher than observed by CBS suggests higher malaria transmission potential in PNG endemic sites compared to previous estimates.

  19. Concerns and perceptions immediately following Superstorm Sandy: ratings for property damage were higher than for health issues.

    Science.gov (United States)

    Burger, Joanna; Gochfeld, Michael

    Governmental officials, health and safety professionals, early responders, and the public are interested in the perceptions and concerns of people faced with a crisis, especially during and immediately after a disaster strikes. Reliable information can lead to increased individual and community preparedness for upcoming crises. The objective of this research was to evaluate concerns of coastal and central New Jersey residents within the first 100 days of Superstorm Sandy's landfall. Respondents living in central New Jersey and Jersey shore communities were differentially impacted by the storm, with shore residents having higher evacuation rates (47% vs. 13%), more flood waters in their homes, longer power outages (average 23 vs. 6 days), and longer periods without Internet (29 vs. 6 days). Ratings of concerns varied both among and within categories as a function of location (central vs. coastal New Jersey), stressor level (ranging from 1 to 3 for combinations of power outages, high winds, and flooding), and demographics. Respondents were most concerned about property damage, health, inconveniences, ecological services, and nuclear power plants in that order. Respondents from the shore gave higher ratings to the concerns within each major category, compared to those from central Jersey. Four findings have implications for understanding future risk, recovery, and resiliency: (1) respondents with the highest stressor level (level 3) were more concerned about water damage than others, (2) respondents with flood damage were more concerned about water drainage and mold than others, (3) respondents with the highest stressor levels rated all ecological services higher than others, and (4) shore respondents rated all ecological services higher than central Jersey residents. These data provide information to design future preparedness plans, improve resiliency for future severe weather events, and reduce public health risk.

  20. Fetal QRS detection and heart rate estimation: a wavelet-based approach

    International Nuclear Information System (INIS)

    Almeida, Rute; Rocha, Ana Paula; Gonçalves, Hernâni; Bernardes, João

    2014-01-01

    Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR. (paper)

  1. Reduction Rates for Higher Americium Oxidation States in Nitric Acid

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, Travis Shane [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mincher, Bruce Jay [Idaho National Lab. (INL), Idaho Falls, ID (United States); Schmitt, Nicholas C [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-30

    The stability of hexavalent americium was measured using multiple americium concentrations and nitric acid concentrations after contact with the strong oxidant sodium bismuthate. Contrary to our hypotheses Am(VI) was not reduced faster at higher americium concentrations, and the reduction was only zero-order at short time scales. Attempts to model the reduction kinetics using zero order kinetic models showed Am(VI) reduction in nitric acid is more complex than the autoreduction processes reported by others in perchloric acid. The classical zero-order reduction of Am(VI) was found here only for short times on the order of a few hours. We did show that the rate of Am(V) production was less than the rate of Am(VI) reduction, indicating that some Am(VI) undergoes two electron-reduction to Am(IV). We also monitored the Am(VI) reduction in contact with the organic diluent dodecane. A direct comparison of these results with those in the absence of the organic diluent showed the reduction rates for Am(VI) were not statistically different for both systems. Additional americium oxidations conducted in the presence of Ce(IV)/Ce(III) ions showed that Am(VI) is reduced without the typical growth of Am(V) observed in the systems sans Ce ion. This was an interesting result which suggests a potential new reduction/oxidation pathway for Am in the presence of Ce; however, these results were very preliminary, and will require additional experiments to understand the mechanism by which this occurs. Overall, these studies have shown that hexavalent americium is fundamentally stable enough in nitric acid to run a separations process. However, the complicated nature of the reduction pathways based on the system components is far from being rigorously understood.

  2. A visible light imaging device for cardiac rate detection with reduced effect of body movement

    Science.gov (United States)

    Jiang, Xiaotian; Liu, Ming; Zhao, Yuejin

    2014-09-01

    A visible light imaging system to detect human cardiac rate is proposed in this paper. A color camera and several LEDs, acting as lighting source, were used to avoid the interference of ambient light. From people's forehead, the cardiac rate could be acquired based on photoplethysmography (PPG) theory. The template matching method was used after the capture of video. The video signal was discomposed into three signal channels (RGB) and the region of interest was chosen to take the average gray value. The green channel signal could provide an excellent waveform of pulse wave on the account of green lights' absorptive characteristics of blood. Through the fast Fourier transform, the cardiac rate was exactly achieved. But the research goal was not just to achieve the cardiac rate accurately. With the template matching method, the effects of body movement are reduced to a large extent, therefore the pulse wave can be detected even while people are in the moving state and the waveform is largely optimized. Several experiments are conducted on volunteers, and the results are compared with the ones gained by a finger clamped pulse oximeter. The contrast results between these two ways are exactly agreeable. This method to detect the cardiac rate and the pulse wave largely reduces the effects of body movement and can probably be widely used in the future.

  3. Recruitment Methods and Show Rates to a Prostate Cancer Early Detection Program for High-Risk Men: A Comprehensive Analysis

    Science.gov (United States)

    Giri, Veda N.; Coups, Elliot J.; Ruth, Karen; Goplerud, Julia; Raysor, Susan; Kim, Taylor Y.; Bagden, Loretta; Mastalski, Kathleen; Zakrzewski, Debra; Leimkuhler, Suzanne; Watkins-Bruner, Deborah

    2009-01-01

    Purpose Men with a family history (FH) of prostate cancer (PCA) and African American (AA) men are at higher risk for PCA. Recruitment and retention of these high-risk men into early detection programs has been challenging. We report a comprehensive analysis on recruitment methods, show rates, and participant factors from the Prostate Cancer Risk Assessment Program (PRAP), which is a prospective, longitudinal PCA screening study. Materials and Methods Men 35–69 years are eligible if they have a FH of PCA, are AA, or have a BRCA1/2 mutation. Recruitment methods were analyzed with respect to participant demographics and show to the first PRAP appointment using standard statistical methods Results Out of 707 men recruited, 64.9% showed to the initial PRAP appointment. More individuals were recruited via radio than from referral or other methods (χ2 = 298.13, p < .0001). Men recruited via radio were more likely to be AA (p<0.001), less educated (p=0.003), not married or partnered (p=0.007), and have no FH of PCA (p<0.001). Men recruited via referrals had higher incomes (p=0.007). Men recruited via referral were more likely to attend their initial PRAP visit than those recruited by radio or other methods (χ2 = 27.08, p < .0001). Conclusions This comprehensive analysis finds that radio leads to higher recruitment of AA men with lower socioeconomic status. However, these are the high-risk men that have lower show rates for PCA screening. Targeted motivational measures need to be studied to improve show rates for PCA risk assessment for these high-risk men. PMID:19758657

  4. Rate of detection of advanced neoplasms in proximal colon by simulated sigmoidoscopy vs fecal immunochemical tests.

    Science.gov (United States)

    Castells, Antoni; Quintero, Enrique; Álvarez, Cristina; Bujanda, Luis; Cubiella, Joaquín; Salas, Dolores; Lanas, Angel; Carballo, Fernando; Morillas, Juan Diego; Hernández, Cristina; Jover, Rodrigo; Hijona, Elizabeth; Portillo, Isabel; Enríquez-Navascués, José M; Hernández, Vicent; Martínez-Turnes, Alfonso; Menéndez-Villalva, Carlos; González-Mao, Carmen; Sala, Teresa; Ponce, Marta; Andrés, Mercedes; Teruel, Gloria; Peris, Antonio; Sopeña, Federico; González-Rubio, Francisca; Seoane-Urgorri, Agustín; Grau, Jaume; Serradesanferm, Anna; Pozo, Àngels; Pellisé, Maria; Balaguer, Francesc; Ono, Akiko; Cruzado, José; Pérez-Riquelme, Francisco; Alonso-Abreu, Inmaculada; Carrillo-Palau, Marta; de la Vega-Prieto, Mariola; Iglesias, Rosario; Amador, Javier; Blanco, José Manuel; Sastre, Rocio; Ferrándiz, Juan; González-Hernández, Ma José; Andreu, Montserrat; Bessa, Xavier

    2014-10-01

    We compared the ability of biennial fecal immunochemical testing (FIT) and one-time sigmoidoscopy to detect colon side-specific advanced neoplasms in a population-based, multicenter, nationwide, randomized controlled trial. We identified asymptomatic men and women, 50-69 years old, through community health registries and randomly assigned them to groups that received a single colonoscopy examination or biennial FIT. Sigmoidoscopy yield was simulated from results obtained from the colonoscopy group, according to the criteria proposed in the UK Flexible Sigmoidoscopy Trial for colonoscopy referral. Patients who underwent FIT and were found to have ≥75 ng hemoglobin/mL were referred for colonoscopy. Data were analyzed from 5059 subjects in the colonoscopy group and 10,507 in the FIT group. The main outcome was rate of detection of any advanced neoplasm proximal to the splenic flexure. Advanced neoplasms were detected in 317 subjects (6.3%) in the sigmoidoscopy simulation group compared with 288 (2.7%) in the FIT group (odds ratio for sigmoidoscopy, 2.29; 95% confidence interval, 1.93-2.70; P = .0001). Sigmoidoscopy also detected advanced distal neoplasia in a higher percentage of patients than FIT (odds ratio, 2.61; 95% confidence interval, 2.20-3.10; P = .0001). The methods did not differ significantly in identifying patients with advanced proximal neoplasms (odds ratio, 1.17; 95% confidence interval, 0.78-1.76; P = .44). This was probably due to the lower performance of both strategies in detecting patients with proximal lesions (sigmoidoscopy detected these in 19.1% of patients and FIT in 14.9% of patients) vs distal ones (sigmoidoscopy detected these in 86.8% of patients and FIT in 33.5% of patients). Sigmoidoscopy, but not FIT, detected proximal lesions in lower percentages of women (especially those 50-59 years old) than men. Sigmoidoscopy and FIT have similar limitations in detecting advanced proximal neoplasms, which depend on patients' characteristics

  5. With age a lower individual breathing reserve is associated with a higher maximal heart rate.

    Science.gov (United States)

    Burtscher, Martin; Gatterer, Hannes; Faulhaber, Martin; Burtscher, Johannes

    2018-01-01

    Maximal heart rate (HRmax) is linearly declining with increasing age. Regular exercise training is supposed to partly prevent this decline, whereas sex and habitual physical activity do not. High exercise capacity is associated with a high cardiac output (HR x stroke volume) and high ventilatory requirements. Due to the close cardiorespiratory coupling, we hypothesized that the individual ventilatory response to maximal exercise might be associated with the age-related HRmax. Retrospective analyses have been conducted on the results of 129 consecutively performed routine cardiopulmonary exercise tests. The study sample comprised healthy subjects of both sexes of a broad range of age (20-86 years). Maximal values of power output, minute ventilation, oxygen uptake and heart rate were assessed by the use of incremental cycle spiroergometry. Linear multivariate regression analysis revealed that in addition to age the individual breathing reserve at maximal exercise was independently predictive for HRmax. A lower breathing reserve due to a high ventilatory demand and/or a low ventilatory capacity, which is more pronounced at a higher age, was associated with higher HRmax. Age explained the observed variance in HRmax by 72% and was improved to 83% when the variable "breathing reserve" was entered. The presented findings indicate an independent association between the breathing reserve at maximal exercise and maximal heart rate, i.e. a low individual breathing reserve is associated with a higher age-related HRmax. A deeper understanding of this association has to be investigated in a more physiological scenario. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Routine perinatal and paediatric post-mortem radiography: detection rates and implications for practice

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [NHS Foundation Trust, Department of Radiology Great Ormond Street Hospital for Children, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom); Calder, Alistair D. [NHS Foundation Trust, Department of Radiology Great Ormond Street Hospital for Children, London (United Kingdom); Kiho, Liina [Camelia Botnar Laboratories Great Ormond Street Hospital for Children, Department of Paediatric Pathology, London (United Kingdom); Taylor, Andrew M. [Great Ormond Street Hospital for Children, Cardiorespiratory Unit, London (United Kingdom); UCL Institute of Cardiovascular Science, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom); Sebire, Neil J. [Camelia Botnar Laboratories Great Ormond Street Hospital for Children, Department of Paediatric Pathology, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom)

    2014-03-15

    Routine perinatal and paediatric post-mortem plain radiography allows for the diagnosis and assessment of skeletal dysplasias, fractures and other bony abnormalities. The aim of this study was to review the diagnostic yield of this practice. We identified 1,027 cases performed in a single institution over a 21/2-year period, including babygrams (whole-body examinations) and full skeletal surveys. Images were reported prior to autopsy in all cases. Radiology findings were cross-referenced with the autopsy findings using an autopsy database. We scored each case from 0 to 4 according to the level of diagnostic usefulness. The overall abnormality rate was 126/1,027 (12.3%). There was a significantly higher rate of abnormality when a skeletal survey was performed (18%) rather than a babygram (10%; P < 0.01); 90% (665/739) of babygrams were normal. Of the 74 abnormal babygrams, we found 33 incidental non-contributory cases, 19 contributory, 20 diagnostic, and 2 false-positive cases. There were only 2 cases out of 739 (0.27%) in whom routine post-mortem imaging identified potentially significant abnormalities that would not have been detected if only selected imaging had been performed. A policy of performing selected, rather than routine, foetal post-mortem radiography could result in a significant cost saving. Routine post-mortem paediatric radiography in foetuses and neonates is neither diagnostically useful nor cost-effective. A more evidence-based, selective protocol should yield significant cost savings. (orig.)

  7. Routine perinatal and paediatric post-mortem radiography: detection rates and implications for practice

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Calder, Alistair D.; Kiho, Liina; Taylor, Andrew M.; Sebire, Neil J.

    2014-01-01

    Routine perinatal and paediatric post-mortem plain radiography allows for the diagnosis and assessment of skeletal dysplasias, fractures and other bony abnormalities. The aim of this study was to review the diagnostic yield of this practice. We identified 1,027 cases performed in a single institution over a 21/2-year period, including babygrams (whole-body examinations) and full skeletal surveys. Images were reported prior to autopsy in all cases. Radiology findings were cross-referenced with the autopsy findings using an autopsy database. We scored each case from 0 to 4 according to the level of diagnostic usefulness. The overall abnormality rate was 126/1,027 (12.3%). There was a significantly higher rate of abnormality when a skeletal survey was performed (18%) rather than a babygram (10%; P < 0.01); 90% (665/739) of babygrams were normal. Of the 74 abnormal babygrams, we found 33 incidental non-contributory cases, 19 contributory, 20 diagnostic, and 2 false-positive cases. There were only 2 cases out of 739 (0.27%) in whom routine post-mortem imaging identified potentially significant abnormalities that would not have been detected if only selected imaging had been performed. A policy of performing selected, rather than routine, foetal post-mortem radiography could result in a significant cost saving. Routine post-mortem paediatric radiography in foetuses and neonates is neither diagnostically useful nor cost-effective. A more evidence-based, selective protocol should yield significant cost savings. (orig.)

  8. Double symbol error rates for differential detection of narrow-band FM

    Science.gov (United States)

    Simon, M. K.

    1985-01-01

    This paper evaluates the double symbol error rate (average probability of two consecutive symbol errors) in differentially detected narrow-band FM. Numerical results are presented for the special case of MSK with a Gaussian IF receive filter. It is shown that, not unlike similar results previously obtained for the single error probability of such systems, large inaccuracies in predicted performance can occur when intersymbol interference is ignored.

  9. Detecting Parental Deception Using a Behavior Rating Scale during Assessment of Attention-Deficit/Hyperactivity Disorder: An Experimental Study

    Science.gov (United States)

    Norfolk, Philip A.; Floyd, Randy G.

    2016-01-01

    It is often assumed that parents completing behavior rating scales during the assessment of attention-deficit/hyperactivity disorder (ADHD) can deliberately manipulate the outcomes of the assessment. To detect these actions, items designed to detect over-reporting or under-reporting of results are sometimes embedded in such rating scales. This…

  10. A burst-mode photon counting receiver with automatic channel estimation and bit rate detection

    Science.gov (United States)

    Rao, Hemonth G.; DeVoe, Catherine E.; Fletcher, Andrew S.; Gaschits, Igor D.; Hakimi, Farhad; Hamilton, Scott A.; Hardy, Nicholas D.; Ingwersen, John G.; Kaminsky, Richard D.; Moores, John D.; Scheinbart, Marvin S.; Yarnall, Timothy M.

    2016-04-01

    We demonstrate a multi-rate burst-mode photon-counting receiver for undersea communication at data rates up to 10.416 Mb/s over a 30-foot water channel. To the best of our knowledge, this is the first demonstration of burst-mode photon-counting communication. With added attenuation, the maximum link loss is 97.1 dB at λ=517 nm. In clear ocean water, this equates to link distances up to 148 meters. For λ=470 nm, the achievable link distance in clear ocean water is 450 meters. The receiver incorporates soft-decision forward error correction (FEC) based on a product code of an inner LDPC code and an outer BCH code. The FEC supports multiple code rates to achieve error-free performance. We have selected a burst-mode receiver architecture to provide robust performance with respect to unpredictable channel obstructions. The receiver is capable of on-the-fly data rate detection and adapts to changing levels of signal and background light. The receiver updates its phase alignment and channel estimates every 1.6 ms, allowing for rapid changes in water quality as well as motion between transmitter and receiver. We demonstrate on-the-fly rate detection, channel BER within 0.2 dB of theory across all data rates, and error-free performance within 1.82 dB of soft-decision capacity across all tested code rates. All signal processing is done in FPGAs and runs continuously in real time.

  11. Structural damage detection using higher-order finite elements and a scanning laser vibrometer

    Science.gov (United States)

    Jin, Si

    In contrast to conventional non-destructive evaluation methods, dynamics-based damage detection methods are capable of rapid integrity evaluation of large structures and have received considerable attention from aerospace, mechanical, and civil engineering communities in recent years. However, the identifiable damage size using dynamics-based methods is determined by the number of sensors used, level of measurement noise, accuracy of structural models, and signal processing techniques. In this thesis we study dynamics of structures with damage and then derive and experimentally verify new model-independent structural damage detection methods that can locate small damage to structures. To find sensitive damage detection parameters we develop a higher-order beam element that enforces the continuity of displacements, slopes, bending moments, and shear forces at all nodes, and a higher-order rectangular plate element that enforces the continuity of displacements, slopes, and bending and twisting moments at all nodes. These two elements are used to study the dynamics of beams and plates. Results show that high-order spatial derivatives of high-frequency modes are important sensitive parameters that can locate small structural damage. Unfortunately the most powerful and popular structural modeling technique, the finite element method, is not accurate in predicting high-frequency responses. Hence, a model-independent method using dynamic responses obtained from high density measurements is concluded to be the best approach. To increase measurement density and reduce noise a Polytec PI PSV-200 scanning laser vibrometer is used to provide non-contact, dense, and accurate measurements of structural vibration velocities. To avoid the use of structural models and to extract sensitive detection parameters from experimental data, a brand-new structural damage detection method named BED (Boundary-Effect Detection) is developed for pinpointing damage locations using Operational

  12. Respiration rate detection based on intensity modulation using plastic optical fiber

    Science.gov (United States)

    Anwar, Zawawi Mohd; Ziran Nurul Sufia, Nor; Hadi, Manap

    2017-11-01

    This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.

  13. Respiration rate detection based on intensity modulation using plastic optical fiber

    Directory of Open Access Journals (Sweden)

    Mohd Anwar Zawawi

    2017-01-01

    Full Text Available This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.

  14. Leadership training to improve adenoma detection rate in screening colonoscopy: A randomised trial

    NARCIS (Netherlands)

    M.F. Kaminski (Michal); J. Anderson (John); R.M. Valori (Roland ); E. Kraszewska (Ewa); M. Rupinski (Maciej); J. Pachlewski (Jacek); E. Wronska (Ewa); M. Bretthauer (Michael); S. Thomas-Gibson (Siwan); E.J. Kuipers (Ernst); J. Regula (J.)

    2016-01-01

    textabstractObjective Suboptimal adenoma detection rate (ADR) at colonoscopy is associated with increased risk of interval colorectal cancer. It is uncertain how ADR might be improved. We compared the effect of leadership training versus feedback only on colonoscopy quality in a countrywide

  15. Graduation Rates and the Higher Education Demographic Evolution

    Science.gov (United States)

    Hunsaker, B. Tom; Thomas, Douglas E.

    2013-01-01

    In his 1918 orienting work, The Higher Learning in America, Veblen highlights two primary aims of the higher education institution: (a) scientific and scholarly inquiry, and (b) the instruction of students (Veblen, 1918). As of 2006, this overarching mission remained intact. In contemporary literature, a common measure of the efficacy of the…

  16. Individual polyp detection rate in routine daily endoscopy practice depends on case-mix.

    Science.gov (United States)

    Loffeld, R J L F; Liberov, B; Dekkers, P E P

    2015-07-01

    The adenoma detection rate (ADR), a marker of endoscopic quality, is confounded by selection bias. It is not known what the ADR is in normal daily practice. To study the polyp detection rate (PDR) in different endoscopists in the course of years. All consecutive endoscopies of the colon done in 11 years were included. Endoscopies in the regular surveillance programme after polyp removal and after surgery because of colorectal cancer or diverticular disease were scored separately. The number of yearly procedures per endoscopist and presence of polyps, anastomoses, surveillance and cancer were noted. In the period of 11 years, 14,908 consecutive endoscopies of colon and rectum were done by four endoscopists. Two endoscopists had a significantly lower PDR than the other two (p case-mix of patients presented for endoscopy. This result debates the use of the ADR as quality indicator for individual endoscopists.

  17. Comparison of higher order spectra in heart rate signals during two techniques of meditation: Chi and Kundalini meditation.

    Science.gov (United States)

    Goshvarpour, Ateke; Goshvarpour, Atefeh

    2013-02-01

    The human heartbeat is one of the important examples of complex physiologic fluctuations. For the first time in this study higher order spectra of heart rate signals during meditation have explored. Specifically, the aim of this study was to analysis and compares the contribution of quadratic phase coupling of human heart rate variability during two forms of meditation: (1) Chinese Chi (or Qigong) meditation and (2) Kundalini Yoga meditation. For this purpose, Bispectrum was estimated by using biased, parametric and the direct (FFT) method. The results show that the mean Bispectrum magnitude of heart rate signals increased during Kundalini Yoga meditation, but it decreased significantly during Chi meditation. However, in both meditation techniques phase-coupled harmonics are shifted to the higher frequencies during meditation. In addition, it has shown that not only there are significant differences between rest and meditation states, but also heart rate patterns appear to be influenced by different types of meditation.

  18. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST)

    Science.gov (United States)

    Friedman, Joshua I.; Xia, Ding; Regatte, Ravinder R.; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates ⩾ 30 s-1) while simultaneously eliminating signals originating from slower (∼5 s-1) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast.

  19. Time-Frequency Analysis of Terahertz Radar Signals for Rapid Heart and Breath Rate Detection

    National Research Council Canada - National Science Library

    Massar, Melody L

    2008-01-01

    We develop new time-frequency analytic techniques which facilitate the detection of a person's heart and breath rates from the Doppler shift the movement of their body induces in a terahertz radar signal...

  20. Higher dosage nicotine patches increase one-year smoking cessation rates : results from the European CEASE trial

    NARCIS (Netherlands)

    Tonnesen, P; Paoletti, P; Gustavsson, G; Russell, MA; Saracci, R; Gulsvik, A; Rijcken, B

    The Collaborative European Anti-Smoking Evaluation (CEASE) was a European multicentre, randomized, double-blind placebo controlled smoking cessation study, The objectives were to determine whether higher dosage and longer duration of nicotine patch therapy would increase the success rate. Thirty-six

  1. Detection rate of serrated polyps and serrated polyposis syndrome in colorectal cancer screening cohorts: a European overview.

    Science.gov (United States)

    IJspeert, J E G; Bevan, R; Senore, C; Kaminski, M F; Kuipers, E J; Mroz, A; Bessa, X; Cassoni, P; Hassan, C; Repici, A; Balaguer, F; Rees, C J; Dekker, E

    2017-07-01

    The role of serrated polyps (SPs) as colorectal cancer precursor is increasingly recognised. However, the true prevalence SPs is largely unknown. We aimed to evaluate the detection rate of SPs subtypes as well as serrated polyposis syndrome (SPS) among European screening cohorts. Prospectively collected screening cohorts of ≥1000 individuals were eligible for inclusion. Colonoscopies performed before 2009 and/or in individuals aged below 50 were excluded. Rate of SPs was assessed, categorised for histology, location and size. Age-sex-standardised number needed to screen (NNS) to detect SPs were calculated. Rate of SPS was assessed in cohorts with known colonoscopy follow-up data. Clinically relevant SPs (regarded as a separate entity) were defined as SPs ≥10 mm and/or SPs >5 mm in the proximal colon. Three faecal occult blood test (FOBT) screening cohorts and two primary colonoscopy screening cohorts (range 1.426-205.949 individuals) were included. Rate of SPs ranged between 15.1% and 27.2% (median 19.5%), of sessile serrated polyps between 2.2% and 4.8% (median 3.3%) and of clinically relevant SPs between 2.1% and 7.8% (median 4.6%). Rate of SPs was similar in FOBT-based cohorts as in colonoscopy screening cohorts. No apparent association between the rate of SP and gender or age was shown. Rate of SPS ranged from 0% to 0.5%, which increased to 0.4% to 0.8% after follow-up colonoscopy. The detection rate of SPs is variable among screening cohorts, and standards for reporting, detection and histopathological assessment should be established. The median rate, as found in this study, may contribute to define uniform minimum standards for males and females between 50 and 75 years of age. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Human papillomavirus detection with genotyping by the cobas and Aptima assays: Significant differences in HPV 16 detection?

    Science.gov (United States)

    Chorny, Joseph A; Frye, Teresa C; Fisher, Beth L; Remmers, Carol L

    2018-03-23

    The primary high-risk human papillomavirus (hrHPV) assays in the United States are the cobas (Roche) and the Aptima (Hologic). The cobas assay detects hrHPV by DNA analysis while the Aptima detects messenger RNA (mRNA) oncogenic transcripts. As the Aptima assay identifies oncogenic expression, it should have a lower rate of hrHPV and genotype detection. The Kaiser Permanente Regional Reference Laboratory in Denver, Colorado changed its hrHPV assay from the cobas to the Aptima assay. The rates of hrHPV detection and genotyping were compared over successive six-month periods. The overall hrHPV detection rates by the two platforms were similar (9.5% versus 9.1%) and not statistically different. For genotyping, the HPV 16 rate by the cobas was 1.6% and by the Aptima it was 1.1%. These differences were statistically different with the Aptima detecting nearly one-third less HPV 16 infections. With the HPV 18 and HPV 18/45, there was a slightly higher detection rate of HPV 18/45 by the Aptima platform (0.5% versus 0.9%) and this was statistically significant. While HPV 16 represents a low percentage of hrHPV infections, it was detected significantly less by the Aptima assay compared to the cobas assay. This has been previously reported, although not highlighted. Given the test methodologies, one would expect the Aptima to detect less HPV 16. This difference appears to be mainly due to a significantly increased number of non-oncogenic HPV 16 infections detected by the cobas test as there were no differences in HPV 16 detection rates in the high-grade squamous intraepithelial lesions indicating that the two tests have similar sensitivities for oncogenic HPV 16. © 2018 Wiley Periodicals, Inc.

  3. Invariance of the bit error rate in the ancilla-assisted homodyne detection

    International Nuclear Information System (INIS)

    Yoshida, Yuhsuke; Takeoka, Masahiro; Sasaki, Masahide

    2010-01-01

    We investigate the minimum achievable bit error rate of the discrimination of binary coherent states with the help of arbitrary ancillary states. We adopt homodyne measurement with a common phase of the local oscillator and classical feedforward control. After one ancillary state is measured, its outcome is referred to the preparation of the next ancillary state and the tuning of the next mixing with the signal. It is shown that the minimum bit error rate of the system is invariant under the following operations: feedforward control, deformations, and introduction of any ancillary state. We also discuss the possible generalization of the homodyne detection scheme.

  4. Nonlinear detection for a high rate extended binary phase shift keying system.

    Science.gov (United States)

    Chen, Xian-Qing; Wu, Le-Nan

    2013-03-28

    The algorithm and the results of a nonlinear detector using a machine learning technique called support vector machine (SVM) on an efficient modulation system with high data rate and low energy consumption is presented in this paper. Simulation results showed that the performance achieved by the SVM detector is comparable to that of a conventional threshold decision (TD) detector. The two detectors detect the received signals together with the special impacting filter (SIF) that can improve the energy utilization efficiency. However, unlike the TD detector, the SVM detector concentrates not only on reducing the BER of the detector, but also on providing accurate posterior probability estimates (PPEs), which can be used as soft-inputs of the LDPC decoder. The complexity of this detector is considered in this paper by using four features and simplifying the decision function. In addition, a bandwidth efficient transmission is analyzed with both SVM and TD detector. The SVM detector is more robust to sampling rate than TD detector. We find that the SVM is suitable for extended binary phase shift keying (EBPSK) signal detection and can provide accurate posterior probability for LDPC decoding.

  5. Nonlinear Detection for a High Rate Extended Binary Phase Shift Keying System

    Directory of Open Access Journals (Sweden)

    Le-Nan Wu

    2013-03-01

    Full Text Available The algorithm and the results of a nonlinear detector using a machine learning technique called support vector machine (SVM on an efficient modulation system with high data rate and low energy consumption is presented in this paper. Simulation results showed that the performance achieved by the SVM detector is comparable to that of a conventional threshold decision (TD detector. The two detectors detect the received signals together with the special impacting filter (SIF that can improve the energy utilization efficiency. However, unlike the TD detector, the SVM detector concentrates not only on reducing the BER of the detector, but also on providing accurate posterior probability estimates (PPEs, which can be used as soft-inputs of the LDPC decoder. The complexity of this detector is considered in this paper by using four features and simplifying the decision function. In addition, a bandwidth efficient transmission is analyzed with both SVM and TD detector. The SVM detector is more robust to sampling rate than TD detector. We find that the SVM is suitable for extended binary phase shift keying (EBPSK signal detection and can provide accurate posterior probability for LDPC decoding.

  6. Bleeding rates necessary for detecting acute gastrointestinal bleeding with technetium-99m-labeled red blood cells in an experimental model

    International Nuclear Information System (INIS)

    Thorne, D.A.; Datz, F.L.; Remley, K.; Christian, P.E.

    1987-01-01

    Proponents of [/sup 99m/Tc]sulfur colloid for GI bleeding studies argue that, although labeled red blood cells are useful for intermittent bleeding, they are not capable of detecting low bleeding rates. Studies of dogs with experimental GI bleeding have indicated bleeding rates of 0.05 ml/min can be detected with [/sup 99m/Tc]sulfur colloid. Since similar data in the dog model were unavailable for /sup 99m/Tc-labeled red blood cells, we undertook this study. To simulate lower GI bleeding, catheters were inserted into the bowel lumen. Each dog's blood was labeled with /sup 99m/Tc using an in vitro technique. Venous blood was then withdrawn and re-infused into the lumen of the bowel using a Harvard pump. Fourteen dogs were studied, ten receiving a bleeding rate from 4.6-0.02 ml/min in the descending colon and four with proximal jejunal bleeds of 0.20-0.02 ml/min. Bleeding rates of 4.6-0.2 ml/min were detected within 10 min in the colon and bleeding rates as low as 0.04 ml/min were seen by 55 min. Slower bleeding rates were not detected. Similar findings were noted for proximal jejunal bleeds. Based on the time of appearance, a minimum volume of approximately 2-3 ml labeled blood was necessary to detect bleeding. We conclude that /sup 99m/Tc-labeled RBCs are sensitive for low bleeding rates in the dog model. The rates are comparable to those described for [/sup 99m/Tc]sulfur colloid in this experimental setting. The time of appearance of activity is related to the bleeding rate

  7. Why the EU-15 Maintains Higher CIT Rates than the New Member States?

    Directory of Open Access Journals (Sweden)

    Karpowicz Andrzej

    2014-11-01

    Full Text Available The European Union is not a homogenous area. This lack of homogeneity extends to taxes, which vary across jurisdictions. On average, Western Europe imposes significantly higher taxes on capital than New Member States, which joined the Community in 2004 and 2007. Often this fact is simply taken for granted. However, there are several arguments that can explain this variance. Although several of these arguments are well known and have been researched, they have not been assessed in combination, or used in a comparative analysis of corporate income tax (CIT rates between EU member states. Because of interest in harmonizing CIT throughout the EU, the roots of divergent CIT is of particular and timely value. Therefore, this article we attempts to demonstrate the differences in CIT rates in the EU-15 and New Member States. In so doing the general characteristics of these country grouping is identified, and then discussed in the context of the taxation theory.

  8. Rabies Vaccination: Higher Failure Rates in Imported Dogs than in those Vaccinated in Italy.

    Science.gov (United States)

    Rota Nodari, E; Alonso, S; Mancin, M; De Nardi, M; Hudson-Cooke, S; Veggiato, C; Cattoli, G; De Benedictis, P

    2017-03-01

    The current European Union (EU) legislation decrees that pets entering the EU from a rabies-infected third country have to obtain a satisfactory virus-neutralizing antibody level, while those moving within the EU require only rabies vaccination as the risk of moving a rabid pet within the EU is considered negligible. A number of factors driving individual variations in dog vaccine response have been previously reported, including a high rate of vaccine failure in puppies, especially those subject to commercial transport. A total of 21 001 observations collected from dogs (2006-2012) vaccinated in compliance with the current EU regulations were statistically analysed to assess the effect of different risk factors related to rabies vaccine efficacy. Within this framework, we were able to compare the vaccination failure rate in a group of dogs entering the Italian border from EU and non-EU countries to those vaccinated in Italy prior to international travel. Our analysis identified that cross-breeds and two breed categories showed high vaccine success rates, while Beagles and Boxers were the least likely to show a successful response to vaccination (88.82% and 90.32%, respectively). Our analysis revealed diverse performances among the commercially available vaccines, in terms of serological peak windows, and marked differences according to geographical area. Of note, we found a higher vaccine failure rate in imported dogs (13.15%) than in those vaccinated in Italy (5.89%). Our findings suggest that the choice of vaccine may influence the likelihood of an animal achieving a protective serological level and that time from vaccination to sampling should be considered when interpreting serological results. A higher vaccine failure in imported compared to Italian dogs highlights the key role that border controls still have in assessing the full compliance of pet movements with EU legislation to minimize the risk of rabies being reintroduced into a disease-free area.

  9. Automatic optimisation of gamma dose rate sensor networks: The DETECT Optimisation Tool

    DEFF Research Database (Denmark)

    Helle, K.B.; Müller, T.O.; Astrup, Poul

    2014-01-01

    of the EU FP 7 project DETECT. It evaluates the gamma dose rates that a proposed set of sensors might measure in an emergency and uses this information to optimise the sensor locations. The gamma dose rates are taken from a comprehensive library of simulations of atmospheric radioactive plumes from 64......Fast delivery of comprehensive information on the radiological situation is essential for decision-making in nuclear emergencies. Most national radiological agencies in Europe employ gamma dose rate sensor networks to monitor radioactive pollution of the atmosphere. Sensor locations were often...... source locations. These simulations cover the whole European Union, so the DOT allows evaluation and optimisation of sensor networks for all EU countries, as well as evaluation of fencing sensors around possible sources. Users can choose from seven cost functions to evaluate the capability of a given...

  10. High detection rate of dog circovirus in diarrheal dogs.

    Science.gov (United States)

    Hsu, Han-Siang; Lin, Ting-Han; Wu, Hung-Yi; Lin, Lee-Shuan; Chung, Cheng-Shu; Chiou, Ming-Tang; Lin, Chao-Nan

    2016-06-17

    Diarrhea is one of the most common clinical symptoms reported in companion animal clinics. Dog circovirus (DogCV) is a new mammalian circovirus that is considered to be a cause of alimentary syndromes such as diarrhea, vomiting and hemorrhagic enteritis. DogCV has previously only been identified in the United States, Italy, Germany (GeneBank accession number: KF887949) and China (GeneBank accession number: KT946839). Therefore, the aims of this study were to determine the prevalence of DogCV in Taiwan and to explore the correlation between diarrhea and DogCV infection. Clinical specimens were collected between 2012 and 2014 from 207 dogs suffering from diarrhea and 160 healthy dogs. In this study, we developed a sensitive and specific SYBR Green-based real-time PCR assays to detected DogCV in naturally infected animals. Of the analyzed fecal samples from diarrheal dogs and health dogs, 58 (28.0 %) and 19 (11.9 %), respectively, were DogCV positive. The difference in DogCV prevalence was highly significant (P = 0.0002755) in diarrheal dogs. This is the first study to reveal that DogCV is currently circulating in domestic dogs in Taiwan and to demonstrate its high detection rate in dogs with diarrhea.

  11. Measurement of the modification and interference rate of urinary albumin detected by size-exclusion HPLC

    International Nuclear Information System (INIS)

    Markó, Lajos; Molnár, Gergő Attila; Wagner, Zoltán; Szijártó, István; Mérei, Ákos; Wittmann, István; Böddi, Katalin; Szabó, Zoltán; Matus, Zoltán; Kőszegi, Tamás; Nagy, Géza

    2009-01-01

    The measurement of the excretion of urinary albumin (albuminuria) is an important and well-established method to assess clinical outcomes. A high-performance liquid chromatography (HPLC) method has been introduced to measure albuminuria. Using this method, it was found that commonly used immunological methods do not measure a fraction of urinary albumin. Some authors presumed that the reason of immuno-unreactivity is the modification of urinary albumin; some others presumed that the difference is merely because of interference. In order to decide this question, we established an HPLC method equipped with tandem UV and fluorescent detection to assess the changes in the detectability of albumin with the rate of modification. For this measurement, differently modified forms of albumin were used. Urine samples of diabetic patients were also measured to find a potential connection between the modification rate and clinical parameters. Secondly, we have established a reversed phase HPLC method to assess the interference rate. We conclude that albumin modification does not affect immunoreactivity. The modification rate of urinary albumin in diabetic patients showed a correlation with renal function. The interference rate of the albumin peak was found to be 12.7% on average, which does not explain the difference between the two methods

  12. Expensive Brains: “Brainy” Rodents have Higher Metabolic Rate

    Science.gov (United States)

    Sobrero, Raúl; May-Collado, Laura J.; Agnarsson, Ingi; Hernández, Cristián E.

    2011-01-01

    Brains are the centers of the nervous system of animals, controlling the organ systems of the body and coordinating responses to changes in the ecological and social environment. The evolution of traits that correlate with cognitive ability, such as relative brain size is thus of broad interest. Brain mass relative to body mass (BM) varies among mammals, and diverse factors have been proposed to explain this variation. A recent study provided evidence that energetics play an important role in brain evolution (Isler and van Schaik, 2006). Using composite phylogenies and data drawn from multiple sources, these authors showed that basal metabolic rate (BMR) correlates with brain mass across mammals. However, no such relationship was found within rodents. Here we re-examined the relationship between BMR and brain mass within Rodentia using a novel species-level phylogeny. Our results are sensitive to parameter evaluation; in particular how species mass is estimated. We detect no pattern when applying an approach used by previous studies, where each species BM is represented by two different numbers, one being the individual that happened to be used for BMR estimates of that species. However, this approach may compromise the analysis. When using a single value of BM for each species, whether representing a single individual, or available species mean, our findings provide evidence that brain mass (independent of BM) and BMR are correlated. These findings are thus consistent with the hypothesis that large brains evolve when the payoff for increased brain mass is greater than the energetic cost they incur. PMID:21811456

  13. Higher order constraints on the Higgs production rate from fixed-target DIS data

    International Nuclear Information System (INIS)

    Alekhin, S.; Bluemlein, J.; Moch, S.

    2011-01-01

    The constraints of fixed-target DIS data in fits of parton distributions including QCD corrections to next-to-next-to leading order are studied. We point out a potential problem in the analysis of the NMC data which can lead to inconsistencies in the extracted value for α s (M Z ) and the gluon distribution at higher orders in QCD. The implications for predictions of rates for Standard Model Higgs boson production at hadron colliders are investigated. We conclude that the current range of excluded Higgs boson masses at the Tevatron appears to be much too large. (orig.)

  14. "Binary" and "non-binary" detection tasks: are current performance measures optimal?

    Science.gov (United States)

    Gur, David; Rockette, Howard E; Bandos, Andriy I

    2007-07-01

    We have observed that a very large fraction of responses for several detection tasks during the performance of observer studies are in the extreme ranges of lower than 11% or higher than 89% regardless of the actual presence or absence of the abnormality in question or its subjectively rated "subtleness." This observation raises questions regarding the validity and appropriateness of using multicategory rating scales for such detection tasks. Monte Carlo simulation of binary and multicategory ratings for these tasks demonstrate that the use of the former (binary) often results in a less biased and more precise summary index and hence may lead to a higher statistical power for determining differences between modalities.

  15. Analysis of variables affecting unemployment rate and detecting for cluster in West Java, Central Java, and East Java in 2012

    Science.gov (United States)

    Samuel, Putra A.; Widyaningsih, Yekti; Lestari, Dian

    2016-02-01

    The objective of this study is modeling the Unemployment Rate (UR) in West Java, Central Java, and East Java, with rate of disease, infant mortality rate, educational level, population size, proportion of married people, and GDRP as the explanatory variables. Spatial factors are also considered in the modeling since the closer the distance, the higher the correlation. This study uses the secondary data from BPS (Badan Pusat Statistik). The data will be analyzed using Moran I test, to obtain the information about spatial dependence, and using Spatial Autoregressive modeling to obtain the information, which variables are significant affecting UR and how great the influence of the spatial factors. The result is, variables proportion of married people, rate of disease, and population size are related significantly to UR. In all three regions, the Hotspot of unemployed will also be detected districts/cities using Spatial Scan Statistics Method. The results are 22 districts/cities as a regional group with the highest unemployed (Most likely cluster) in the study area; 2 districts/cities as a regional group with the highest unemployed in West Java; 1 district/city as a regional groups with the highest unemployed in Central Java; 15 districts/cities as a regional group with the highest unemployed in East Java.

  16. Significantly increased detection rate of drugs of abuse in urine following the introduction of new German driving licence re-granting guidelines.

    Science.gov (United States)

    Agius, Ronald; Nadulski, Thomas; Kahl, Hans-Gerhard; Dufaux, Bertin

    2012-02-10

    In this paper we present the first assessment of the new German driving licence re-granting medical and psychological assessment (MPA) guidelines by comparing over 3500 urine samples tested under the old MPA cut-offs to over 5000 samples tested under the new MPA cut-offs. Since the enzyme multiplied immunoassay technique (EMIT) technology used previously was not sensitive enough to screen for drugs at such low concentrations, as suggested by the new MPA guidelines, enzyme-linked immunosorbent assay (ELISA) screening kits were used to screen for the drugs of abuse at the new MPA cut-offs. The above comparison revealed significantly increased detection rates of drug use or exposure during the rehabilitation period as follows: 1.61, 2.33, 3.33, and 7 times higher for 11-nor-delta-9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH), morphine, benzoylecgonine and amphetamine respectively. The present MPA guidelines seem to be more effective to detect non-abstinence from drugs of abuse and hence to detecting drivers who do not yet fulfil the MPA requirements to regain their revoked driving licence. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  17. 3D computer-aided detection for digital breast tomosynthesis: Comparison with 2D computer-aided detection for digital mammography in the detection of calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Chu, A Jung; Cho, Nariya; Chang, Jung Min; Kim, Won Hwa; Lee, Su Hyun; Song, Sung Eun; Shin, Sung Ui; Moon, Woo Kyung [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-08-15

    To retrospectively evaluate the performance of 3D computer-aided detection (CAD) for digital breast tomosynthesis (DBT) in the detection of calcifications in comparison with 2D CAD for digital mammography (DM). Between 2012 and 2013, both 3D CAD and 2D CAD systems were retrospectively applied to the calcification data set including 69 calcifications (31 malignant calcifications and 38 benign calcifications) and the normal data set including 20 bilateral normal mammograms. Each data set consisted of paired DBT and DM images. Sensitivities for the detection of malignant calcifications were calculated from the calcification data set. False-positive mark rates were calculated from the normal data set. They were compared between the two systems. Sensitivities of 3D CAD [100% (31/31) at levels 2, 1, and 0] were same as those of the 2D CAD system [100% (31/31) at levels 2 and 1] (p = 1.0, respectively). The mean value of false-positive marks per view with 3D CAD was higher than that with 2D CAD at level 2 (0.52 marks ± 0.91 vs. 0.07 marks ± 0.26, p = 0.009). 3D CAD for DBT showed equivalent sensitivity, albeit with a higher false-positive mark rate, than 2D CAD for DM in the detection of calcifications.

  18. Detectability of changes in cosmic-ray counting rate measured with the Liulin detector

    International Nuclear Information System (INIS)

    Malusek, A.; Kubancak, J.; Ambrozova, I.

    2011-05-01

    Experimental data are needed to improve and validate models predicting the dynamics of solar particle events because the mechanisms of processes leading to the acceleration of solar energetic particles are not yet fully understood. The aim of this work was to examine whether the spectrometer of deposited energy, Liulin, positioned at the Lomnický štít mountain observatory can collect such data. Decision thresholds and detection limits for the increase or decrease in the average number of particles detected by Liulin were determined for a period in February 2011. The changes in counts corresponding to the decision thresholds and detection limits relative to the average number of detected particles were about 17% and 33%, respectively. The Forbush decrease with a maximum change of about 6.8%, which started on February 18, was detectable neither during the 10-minute acquisition time nor during any other, longer period. Statistical analysis showed that an acquisition time about 7 hours would be needed to detect a 5% decrease. As this time was shorter than the duration of the Forbush decrease (about 56 hours), we theorize that the current placement of the Liulin detector inside a living room shielded by a thick concrete ceiling may have had an adverse impact on the detectability of the the cosmic ray counting rate decrease. To test this hypothesis, we recommend positioning the Liulin detector outside the main observatory building.. (author)

  19. Invasive acacias experience higher ant seed removal rates at the invasion edges

    Directory of Open Access Journals (Sweden)

    D. Montesinos

    2012-06-01

    Full Text Available Seed dispersal is a key process for the invasion of new areas by exotic species. Introduced plants often take advantage of native generalist dispersers. Australian acacias are primarily dispersed by ants in their native range and produce seeds bearing a protein and lipid rich reward for ant mutualists (elaiosome. Nevertheless, the role of myrmecochory in the expansion of Australian acacias in European invaded areas is still not clear. We selected one European population of Acacia dealbata and another of A. longifolia and offered elaiosome-bearing and elaiosome-removed seeds to local ant communities. For each species, seeds were offered both in high-density acacia stands and in low-density invasion edges. For both acacia species, seed removal was significantly higher at the low-density edges. For A. longifolia, manual elimination of elaiosomes reduced the chance of seed removal by 80% in the low-density edges, whereas it made no difference on the high-density stands. For A. dealbata, the absence of elaiosome reduced seed removal rate by 52%, independently of the acacia density. Our data suggests that invasive acacias have found effective ant seed dispersers in Europe and that the importance of such dispersers is higher at the invasion edges.

  20. Detection and Modeling of Non-Tidal Oceanic Effects on the Earth's Rotation Rate

    Science.gov (United States)

    Marcus, S. L.; Chao, Y.; Dickey, J. O.; Gegout, P.

    1998-01-01

    Sub-decadal changes in the Earth's rotation rate, and hence in the length-of-day (LOD), are largely controlled by variations in atmospheric angular momentum. Results from two oceanic general circulation models (OGCMs), forced by observed wind stress and heat flux for the years 1992-1994, show that ocean current and mass distribution changes also induce detectable LOD variations.

  1. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST).

    Science.gov (United States)

    Friedman, Joshua I; Xia, Ding; Regatte, Ravinder R; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates⩾30s(-1)) while simultaneously eliminating signals originating from slower (∼5s(-1)) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Higher dose rate Gamma Knife radiosurgery may provide earlier and longer-lasting pain relief for patients with trigeminal neuralgia.

    Science.gov (United States)

    Lee, John Y K; Sandhu, Sukhmeet; Miller, Denise; Solberg, Timothy; Dorsey, Jay F; Alonso-Basanta, Michelle

    2015-10-01

    Gamma Knife radiosurgery (GKRS) utilizes cobalt-60 as its radiation source, and thus dose rate varies as the fixed source decays over its half-life of approximately 5.26 years. This natural decay results in increasing treatment times when delivering the same cumulative dose. It is also possible, however, that the biological effective dose may change based on this dose rate even if the total dose is kept constant. Because patients are generally treated in a uniform manner, radiosurgery for trigeminal neuralgia (TN) represents a clinical model whereby biological efficacy can be tested. The authors hypothesized that higher dose rates would result in earlier and more complete pain relief but only if measured with a sensitive pain assessment tool. One hundred thirty-three patients were treated with the Gamma Knife Model 4C unit at a single center by a single neurosurgeon during a single cobalt life cycle from January 2006 to May 2012. All patients were treated with 80 Gy with a single 4-mm isocenter without blocking. Using an output factor of 0.87, dose rates ranged from 1.28 to 2.95 Gy/min. The Brief Pain Inventory (BPI)-Facial was administered before the procedure and at the first follow-up office visit 1 month from the procedure (mean 1.3 months). Phone calls were made to evaluate patients after their procedures as part of a retrospective study. Univariate and multivariate linear regression was performed on several independent variables, including sex, age in deciles, diagnosis, follow-up duration, prior surgery, and dose rate. In the short-term analysis (mean 1.3 months), patients' self-reported pain intensity at its worst was significantly correlated with dose rate on multivariate analysis (p = 0.028). Similarly, patients' self-reported interference with activities of daily living was closely correlated with dose rate on multivariate analysis (p = 0.067). A 1 Gy/min decrease in dose rate resulted in a 17% decrease in pain intensity at its worst and a 22% decrease

  3. ESTIMATING RETURN RATE OF HIGHER EDUCATION FUND IN RUSSIA

    Directory of Open Access Journals (Sweden)

    Semenikhina V. A.

    2014-06-01

    Full Text Available Currently, the Russian government pays great attention to the field of higher and postgraduate education. But in the Russian scientific literature there are gaps related to the effectiveness of the overall evaluation of the higher education sector. The article dwells upon the problem of interregional income spread of the Russian population. Empirical estimator of difference influence accounting for human capital accumulated in Russian regions on wage levels and maximum increase of total wage levels and population income for 2001-2011 is carried out. Higher education, exceeding the influence of accumulated volume of the main funds, has a great influence on income spread in Russian regions. Besides, increase of higher education fund in Russian regions contributes to the population’s wage increase and growth in income, but at the same time it decreases legal wages. Results of the study extend knowledge of the economics of education of the Russian Federation.

  4. Relationship between PSA kinetics and [{sup 18}F]fluorocholine PET/CT detection rates of recurrence in patients with prostate cancer after total prostatectomy

    Energy Technology Data Exchange (ETDEWEB)

    Graute, Vera; Jansen, Nathalie; Uebleis, Christopher; Cumming, Paul; Klanke, Katharina; Tiling, Reinhold; Bartenstein, Peter; Hacker, Marcus [University of Munich, Department of Nuclear Medicine, Munich (Germany); Seitz, Michael [University of Munich, Department of Urology, Munich (Germany); Hartenbach, Markus [Bundeswehrkrankenhaus Ulm, Department of Nuclear Medicine, Ulm (Germany); Scherr, Michael Karl; Thieme, Sven [University of Munich, Institute of Clinical Radiology, Munich (Germany)

    2012-02-15

    The aim of the present study was to identify prostate-specific antigen (PSA) threshold levels, as well as PSA velocity, progression rate and doubling time in relation to the detectability and localization of recurrent lesions with [{sup 18}F]fluorocholine (FC) PET/CT in patients after radical prostatectomy. The study group comprised 82 consecutive patients with biochemical relapse after radical prostatectomy. PSA levels measured at the time of imaging were correlated with the FC PET/CT detection rates in the entire group with PSA velocity (in 48 patients), with PSA doubling time (in 47 patients) and with PSA progression (in 29 patients). FC PET/CT detected recurrent lesions in 51 of the 82 patients (62%). The median PSA value was significantly higher in PET-positive than in PET-negative patients (4.3 ng/ml vs. 1.0 ng/ml; p < 0.01). The optimal PSA threshold from ROC analysis for the detection of recurrent prostate cancer lesions was 1.74 ng/ml (AUC 0.818, 82% sensitivity, 74% specificity). Significant differences between PET-positive and PET-negative patients were found for median PSA velocity (6.4 vs. 1.1 ng/ml per year; p < 0.01) and PSA progression (5.0 vs. 0.3 ng/ml per year, p < 0.01) with corresponding optimal thresholds of 1.27 ng/ml per year and 1.28 ng/ml per year, respectively. The PSA doubling time suggested a threshold of 3.2 months, but this just failed to reach statistical significance (p = 0.071). In a study cohort of patients with biochemical recurrence of prostate cancer after radical prostatectomy there emerged clear PSA thresholds for the presence of FC PET/CT-detectable lesions. (orig.)

  5. Does adding metformin to clomifene citrate lead to higher pregnancy rates in a subset of women with polycystic ovary syndrome?

    OpenAIRE

    Moll, E.; Korevaar, J.C.; Bossuyt, P.M.M.; van der Veen, F.

    2008-01-01

    BACKGROUND An RCT among newly diagnosed, therapy naive women with polycystic ovary syndrome (PCOS) showed no significant differences in ovulation rate, ongoing pregnancy rate or spontaneous abortion rate in favour of clomifene citrate plus metformin compared with clomifene citrate. We wanted to assess whether there are specific subgroups of women with PCOS in whom clomifene citrate plus metformin leads to higher pregnancy rates. METHODS Subgroup analysis based on clinical and biochemical para...

  6. A method of detection of respiration rate on Android using UWB Impulse Radar

    Directory of Open Access Journals (Sweden)

    Young-Jin Park

    2016-12-01

    Full Text Available Monitoring respiration rate is important because it can help to detect and prevent abnormal respiratory rates that can lead to cardiac arrest and chronic obstructive pulmonary disease. Nowadays, most medical measurement and monitoring devices are either invasive or wired but people are hesitant to attach physiological sensors to their body. In this study, we investigated whether real-time medical measurement of breathing using Novelda’s Ultra-Wideband Impulse Radio (IR-UWB–which does not need to be attached to the human body and is also non-invasive–is possible on Android. Experimental results obtained were found to be comparable to those of a commercial healthcare device.

  7. The Active Management of Risk in Multiparous Pregnancy at Term: association between a higher preventive labor induction rate and improved birth outcomes

    Science.gov (United States)

    Nicholson, James M.; Caughey, Aaron; Stenson, Ms. Morghan H.; Cronholm, Peter; Kellar, Lisa; Bennett, Ian; Margo, Katie; Stratton, Joseph

    2009-01-01

    Objective To determine if exposure of multiparous women to a high rate of preventive labor induction was associated with a significantly lower cesarean delivery rate. Study Design Retrospective cohort study involving 123 multiparas, who were exposed to the frequent use of preventive labor induction, and 304 multiparas, who received standard management. Rates of cesarean delivery and other adverse birth outcomes were compared in the two groups. Logistic regression controlled for confounding covariates. Results The exposed group had a lower cesarean delivery rate (aOR 0.09, 0.8% vs. 9.9%, p = 0.02) and a higher uncomplicated vaginal delivery rate (OR 0.53, 78.9% vs. 66.4%, p=0.01). Exposure was not associated with higher rates of other adverse birth outcomes. Conclusion Exposure of multiparas to a high rate of preventive labor induction was significantly associated with improved birth outcomes including a very low cesarean delivery rate. A prospective randomized trial is needed to determine causality. PMID:19254584

  8. Biometric Quantization through Detection Rate Optimized Bit Allocation

    Directory of Open Access Journals (Sweden)

    C. Chen

    2009-01-01

    Full Text Available Extracting binary strings from real-valued biometric templates is a fundamental step in many biometric template protection systems, such as fuzzy commitment, fuzzy extractor, secure sketch, and helper data systems. Previous work has been focusing on the design of optimal quantization and coding for each single feature component, yet the binary string—concatenation of all coded feature components—is not optimal. In this paper, we present a detection rate optimized bit allocation (DROBA principle, which assigns more bits to discriminative features and fewer bits to nondiscriminative features. We further propose a dynamic programming (DP approach and a greedy search (GS approach to achieve DROBA. Experiments of DROBA on the FVC2000 fingerprint database and the FRGC face database show good performances. As a universal method, DROBA is applicable to arbitrary biometric modalities, such as fingerprint texture, iris, signature, and face. DROBA will bring significant benefits not only to the template protection systems but also to the systems with fast matching requirements or constrained storage capability.

  9. Does preoperative breast MRI significantly impact on initial surgical procedure and re-operation rates in patients with screen-detected invasive lobular carcinoma?

    International Nuclear Information System (INIS)

    Sinclair, K.; Sakellariou, S.; Dawson, N.; Litherland, J.

    2016-01-01

    Aim: To investigate whether magnetic resonance imaging (MRI) changes the management of patients with screen-detected invasive lobular carcinoma (ILC). Materials and methods: A retrospective, controlled, single-centre analysis of 138 cases of screen-detected ILC was performed. All patients were assessed by a single multidisciplinary team as to whether preoperative MRI altered the initial management decision or reduced re-operation rates. Results: Forty-three percent of patients had preoperative MRI. MRI guided surgical management in 40.7% patients. Primary mastectomy rates were not significantly different between the MRI and non-MRI groups (32% and 30% respectively, p=0.71). The MRI group had a lower secondary surgery rate (6.8% versus 15.2%); however, the results did not reach statistical significance, and there were no unnecessary mastectomies. Conclusion: MRI can be used appropriately to guide primary surgery in screen-detected ILC cases and affects the initial management decision in 40.7% of patients. It does not significantly affect the overall mastectomy rate or re-operation rates, but reduces the likelihood of the latter. As a result of this review, the authors' local policy for the use of MRI in screen-detected ILC patients has been modified. For patients undergoing mastectomy for ILC, MRI is no longer performed routinely to search for contralateral malignancy as this has no proven added benefit. - Highlights: • Breast magnetic resonance imaging (MRI) allows more accurate tumour assessment and detects additional foci of disease in invasive lobular carcinoma (ILC). • Over the study's 3 year time frame, MRI guided surgical management of 40.7% screen-detected ILC patients scanned. • No statistically significant difference in mastectomy rates between MRI and non MRI groups. • Observed lower re-operation rate (6.8%-v-15.2%) in MRI group not statistically significant. • No MRI benefit for contralateral disease detection in ILC patients for

  10. LASER: A Maximum Likelihood Toolkit for Detecting Temporal Shifts in Diversification Rates From Molecular Phylogenies

    Directory of Open Access Journals (Sweden)

    Daniel L. Rabosky

    2006-01-01

    Full Text Available Rates of species origination and extinction can vary over time during evolutionary radiations, and it is possible to reconstruct the history of diversification using molecular phylogenies of extant taxa only. Maximum likelihood methods provide a useful framework for inferring temporal variation in diversification rates. LASER is a package for the R programming environment that implements maximum likelihood methods based on the birth-death process to test whether diversification rates have changed over time. LASER contrasts the likelihood of phylogenetic data under models where diversification rates have changed over time to alternative models where rates have remained constant over time. Major strengths of the package include the ability to detect temporal increases in diversification rates and the inference of diversification parameters under multiple rate-variable models of diversification. The program and associated documentation are freely available from the R package archive at http://cran.r-project.org.

  11. Detection of exudates in fundus imagery using a constant false-alarm rate (CFAR) detector

    Science.gov (United States)

    Khanna, Manish; Kapoor, Elina

    2014-05-01

    Diabetic retinopathy is the leading cause of blindness in adults in the United States. The presence of exudates in fundus imagery is the early sign of diabetic retinopathy so detection of these lesions is essential in preventing further ocular damage. In this paper we present a novel technique to automatically detect exudates in fundus imagery that is robust against spatial and temporal variations of background noise. The detection threshold is adjusted dynamically, based on the local noise statics around the pixel under test in order to maintain a pre-determined, constant false alarm rate (CFAR). The CFAR detector is often used to detect bright targets in radar imagery where the background clutter can vary considerably from scene to scene and with angle to the scene. Similarly, the CFAR detector addresses the challenge of detecting exudate lesions in RGB and multispectral fundus imagery where the background clutter often exhibits variations in brightness and texture. These variations present a challenge to common, global thresholding detection algorithms and other methods. Performance of the CFAR algorithm is tested against a publicly available, annotated, diabetic retinopathy database and preliminary testing suggests that performance of the CFAR detector proves to be superior to techniques such as Otsu thresholding.

  12. Noise-tolerant instantaneous heart rate and R-peak detection using short-term autocorrelation for wearable healthcare systems.

    Science.gov (United States)

    Fujii, Takahide; Nakano, Masanao; Yamashita, Ken; Konishi, Toshihiro; Izumi, Shintaro; Kawaguchi, Hiroshi; Yoshimoto, Masahiko

    2013-01-01

    This paper describes a robust method of Instantaneous Heart Rate (IHR) and R-peak detection from noisy electrocardiogram (ECG) signals. Generally, the IHR is calculated from the R-wave interval. Then, the R-waves are extracted from the ECG using a threshold. However, in wearable bio-signal monitoring systems, noise increases the incidence of misdetection and false detection of R-peaks. To prevent incorrect detection, we introduce a short-term autocorrelation (STAC) technique and a small-window autocorrelation (SWAC) technique, which leverages the similarity of QRS complex waveforms. Simulation results show that the proposed method improves the noise tolerance of R-peak detection.

  13. Clinical significance of combined detection of CYFRA21-1, NSE and CEA in classification and staging of patients with lung cancer

    International Nuclear Information System (INIS)

    Hu He; Li Yanhua; Liang Weida; Zhang Qin

    2011-01-01

    To explore clinical value of combined detection of CYFRA21-1, NSE and CEA in classification and staging of patients with lung cancer, the CYFRA21-1, NSE and CEA levels in pleural effusion in 330 patients with lung cancer and in 43 patients with benign were detected by the electrochemiluminescence. The results showed that CYFRA21-1, NSE and CEA levels in pleural effusion in patients with lung cancer group were significantly higher than that of in benign group (P<0.01). The positive rate of tumor markers in different pathological type lung cancer were different,which CYFRA21-1 positive rate in squamous cell cancer group was highest with 65.5%; CEA positive rate in glands cancer group was supreme with 65.0%; the NSE positive rate in differentiation cancer group was highest with 79.5%. The positive rate in three markers combined detection was higher than that in one item detection. The tumor marker levels in lung cancer were positively related with clinical staging. The higher of tumor marker levels and the more late of clinical staging, and the clinical III∼IV period was obviously higher than that I∼II period (P<0.05). The combined detection of CYFRA21-1, NSE and CEA may enhance the positive rate in lung cancer detection, and may have significant clinical value in the classification and staging of patients with lung cancer. (authors)

  14. Developing a Digital Medicine System in Psychiatry: Ingestion Detection Rate and Latency Period.

    Science.gov (United States)

    Profit, Deborah; Rohatagi, Shashank; Zhao, Cathy; Hatch, Ainslie; Docherty, John P; Peters-Strickland, Timothy S

    2016-09-01

    A digital medicine system (DMS) has been developed to measure and report adherence to an atypical antipsychotic, aripiprazole, in psychiatric patients. The DMS consists of 3 components: ingestible sensor embedded in a medication tablet, wearable sensor, and secure mobile and cloud-based applications. An umbrella study protocol was designed to rapidly assess the technical performance and safety of the DMS in multiple substudies to guide the technology development. Two sequential substudies enrolled 30 and 29 healthy volunteers between March-April 2014 and February-March 2015, respectively, to assess detection accuracy of the ingestible sensor by the DMS and the latency period between ingestion and detection of the ingestion by the wearable sensor or the cloud-based server. The first substudy identified areas for improvement using early versions of the wearable sensor and the mobile application. The second substudy tested updated versions of the components and showed an overall ingestion detection rate of 96.6%. Mean latency times for the signal transmission were 1.1-1.3 minutes (from ingestion to the wearable sensor detection) and 6.2-10.3 minutes (from the wearable sensor detection to the server detection). Half of transmissions were completed in < 2 minutes, and ~90% of ingestions were registered by the smartphone within 30 minutes of ingestion. No serious adverse events, discontinuations, or clinically significant laboratory/vital signs findings were reported. The DMS implementing modified versions of the smartphone application and the wearable sensor has the technical capability to detect and report tablet ingestion with high accuracy and acceptable latency time. ClinicalTrials.gov identifier: NCT02091882. © Copyright 2016 Physicians Postgraduate Press, Inc.

  15. Higher Rates of DZ Twinning in a Twenty-First Century Birth Cohort.

    Science.gov (United States)

    Rhea, Sally Ann; Corley, Robin P; Heath, Andrew C; Iacono, William G; Neale, Michael C; Hewitt, John K

    2017-09-01

    The Colorado Twin Registry is a population based registry initiated in 1984 with the involvement of the Colorado Department of Health, Division of Vital Statistics. Recruitment includes birth cohorts several years prior to 1984 and all subsequent years. As part of a recent evaluation of Colorado birth records for the years 2006 through 2008 we became aware of a shifting trend in the proportion of MZ and DZ twins in the Colorado population. Historically (Bulmer 1970 The biology of twinning in man, Clarendon, Oxford) we have expected a 1/3, 1/3, 1/3 ratio of MZ, same-sex DZ and opposite sex DZ twins in Caucasian populations. An excess of MZ pairs in most studies was assumed to be due to selection bias. Somewhat more recently, Hur et al.(1995 Behav Genet 25, 337-340) provided evidence that the DZ twinning rate was falling and that therefore selection bias was not the reason for higher MZ enrollment in most twin studies. They suggested that twin researchers might consider strategies to over-enroll DZ pairs to maximize statistical power. In contrast, we now find that of the 3217 twin births in Colorado from 2006 to 2008 with identified sex information the MZ rate is estimated at only 22%, and we have corroborating reports from other states of similar estimates. These were calculated applying Weinberg's rule which assumes an equal birth rate for same sex and opposite sex DZ pairs so that the proportion of MZ in a sample is the proportion of same sex (MM + FF) minus the proportion of opposite-sex (MF, FM). We explore factors, such as an increase in the proportion of non-Caucasian parents and an increase in average maternal age, which may contribute to this shift.

  16. Increased Cancer Detection Rate and Variations in the Recall Rate Resulting from Implementation of 3D Digital Breast Tomosynthesis into a Population-based Screening Program

    Science.gov (United States)

    Venkataraman, Shambavi; Phillips, Jordana; Dialani, Vandana; Fein-Zachary, Valerie J.; Prakash, Seema; Slanetz, Priscilla J.; Mehta, Tejas S.

    2016-01-01

    Purpose To compare the recall and cancer detection rates (CDRs) at screening with digital breast tomosynthesis (DBT) with those at screening with two-dimensional (2D) mammography and to evaluate variations in the recall rate (RR) according to patient age, risk factors, and breast density and among individual radiologists at a single U.S. academic medical center. Materials and Methods This institutional review board–approved, HIPAA-compliant prospective study with a retrospective cohort included 85 852 asymptomatic women who presented for breast cancer screening over a 3-year period beginning in 2011. A DBT unit was introduced into the existing 2D mammography screening program, and patients were assigned to the first available machine. Ten breast-subspecialized radiologists interpreted approximately 90% of the examinations. RRs were calculated overall and according to patient age, breast density, and individual radiologist. CDRs were calculated. Single and multiple mixed-effect logistic regression analyses, χ2 tests, and Bonferroni correction were utilized, as appropriate. Results The study included 5703 (6.6%) DBT examinations and 80 149 (93.4%) 2D mammography examinations. The DBT subgroup contained a higher proportion of patients with risk factors for breast cancer and baseline examinations. DBT was used to detect 54.3% more carcinomas (+1.9 per 1000, P < .0018) than 2D mammography. The RR was 7.51% for 2D mammography and 6.10% for DBT (absolute change, 1.41%; relative change, –18.8%; P < .0001). The DBT subgroup demonstrated a significantly lower RR for patients with extremely or heterogeneously dense breasts and for patients in their 5th and 7th decades. Conclusion Implementing DBT into a U.S. breast cancer screening program significantly decreased the screening RR overall and for certain patient subgroups, while significantly increasing the CDR. These findings may encourage more widespread adoption and reimbursement of DBT and facilitate improved patient

  17. Improved detection rate of structural abnormalities in the first trimester using an extended examination protocol.

    Science.gov (United States)

    Iliescu, D; Tudorache, S; Comanescu, A; Antsaklis, P; Cotarcea, S; Novac, L; Cernea, N; Antsaklis, A

    2013-09-01

    To assess the potential of first-trimester sonography in the detection of fetal abnormalities using an extended protocol that is achievable with reasonable resources of time, personnel and ultrasound equipment. This was a prospective two-center 2-year study of 5472 consecutive unselected pregnant women examined at 12 to 13 + 6 gestational weeks. Women were examined using an extended morphogenetic ultrasound protocol that, in addition to the basic evaluation, involved a color Doppler cardiac sweep and identification of early contingent markers for major abnormalities. The prevalence of lethal and severe malformations was 1.39%. The first-trimester scan identified 40.6% of the cases detected overall and 76.3% of major structural defects. The first-trimester detection rate (DR) for major congenital heart disease (either isolated or associated with extracardiac abnormalities) was 90% and that for major central nervous system anomalies was 69.5%. In fetuses with increased nuchal translucency (NT), the first-trimester DR for major anomalies was 96%, and in fetuses with normal NT it was 66.7%. Most (67.1%) cases with major abnormalities presented with normal NT. A detailed first-trimester anomaly scan using an extended protocol is an efficient screening method to detect major fetal structural abnormalities in low-risk pregnancies. It is feasible at 12 to 13 + 6 weeks with ultrasound equipment and personnel already used for routine first-trimester screening. Rate of detection of severe malformations is greater in early- than in mid-pregnancy and on postnatal evaluation. Early heart investigation could be improved by an extended protocol involving use of color Doppler. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  18. Sensitivity of new detection method for ultra-low frequency gravitational waves with pulsar spin-down rate statistics

    Science.gov (United States)

    Yonemaru, Naoyuki; Kumamoto, Hiroki; Takahashi, Keitaro; Kuroyanagi, Sachiko

    2018-04-01

    A new detection method for ultra-low frequency gravitational waves (GWs) with a frequency much lower than the observational range of pulsar timing arrays (PTAs) was suggested in Yonemaru et al. (2016). In the PTA analysis, ultra-low frequency GWs (≲ 10-10 Hz) which evolve just linearly during the observation time span are absorbed by the pulsar spin-down rates since both have the same effect on the pulse arrival time. Therefore, such GWs cannot be detected by the conventional method of PTAs. However, the bias on the observed spin-down rates depends on relative direction of a pulsar and GW source and shows a quadrupole pattern in the sky. Thus, if we divide the pulsars according to the position in the sky and see the difference in the statistics of the spin-down rates, ultra-low frequency GWs from a single source can be detected. In this paper, we evaluate the potential of this method by Monte-Carlo simulations and estimate the sensitivity, considering only the "Earth term" while the "pulsar term" acts like random noise for GW frequencies 10-13 - 10-10 Hz. We find that with 3,000 milli-second pulsars, which are expected to be discovered by a future survey with the Square Kilometre Array, GWs with the derivative of amplitude of about 3 × 10^{-19} {s}^{-1} can in principle be detected. Implications for possible supermassive binary black holes in Sgr* and M87 are also given.

  19. [Evaluation of heart impact in the 100 m extreme intensity sport using near-infrared non-invasive muscle oxygen detecting device and sports heart rate detection technology].

    Science.gov (United States)

    Wang, Pei-Yong; Long, Fei-Xiao; Fu, Lan-Ying; Li, Yue; Ding, Hai-Shu; Qu, An-Lian; Zhou, Xiao-Ping

    2010-02-01

    Using continuous two wavelength near-infrared technology to detect the variation in the consistency of oxygen hemoglobin in the muscle and the sports heart rate wireless real time collection technology, we devised the real time muscle tissue oxygenation and instantaneous heart rate experiment scheme and implemented it for the process of the 100 m run with two parameters given simultaneously. The experiment shows that the concentration of the oxygen hemoglobin in the muscle tissue continues decreasing after the end of the 100 m run, and the time interval between the moment when the concentration of the oxygen hemoglobin attains the minimum value and the moment when the athletes finish the 100 m run is (6.65 +/- 1.10) sec; while the heart rate continues increasing after the end of the 100 m run, and the time interval between the moment when the heart rate attains the maximum value and the moment when the athletes finish the 100 m run is (8.00 +/- 1.57) sec. The results show that the two wavelength near-infrared tissue oxygenation detection technology and the sports heart rate real time collection equipment can accurately measure the sports tissue oxygenation and the heart rate in the extreme intensity sport, and reveal the process of muscle oxygen transportation and consumption and its dynamic character with the heart rate in the extreme intensity sport.

  20. A Low-Power Wireless Image Sensor Node with Noise-Robust Moving Object Detection and a Region-of-Interest Based Rate Controller

    Science.gov (United States)

    2017-03-01

    from both environment and hardware further reduces the transmission energy with negligible computation and memory overhead. The rate controller...detection, Region-of-interest, Rate control Introduction In wireless image sensor nodes for moving object surveillance, energy efficiency can be...noise, reliable moving object detection is required to avoid unnecessary transmission of background scenes [1]. Transmission energy can be further

  1. A new islanding detection technique for multiple mini hydro based on rate of change of reactive power and load connecting strategy

    International Nuclear Information System (INIS)

    Laghari, J.A.; Mokhlis, H.; Bakar, A.H.A.; Karimi, M.

    2013-01-01

    Highlights: • The requirement of DG interconnection with existing power system is discussed. • Various islanding detection techniques are discussed with their merits and demerits. • New islanding detection strategy is proposed for multiple mini hydro type DGs. • The proposed strategy is based on dq/dt and load connecting strategy. • The effectiveness of strategy is verified on various other cases. - Abstract: The interconnection of distributed generation (DG) into distribution networks is undergoing a rapid global expansion. It enhances the system’s reliability, while simultaneously reduces pollution problems related to the generation of electrical power. To fully utilize the benefits of DGs, certain technical issues need to be addressed. One of the most important issues in this context is islanding detection. This paper presents a new islanding detection technique that is suitable for multiple mini-hydro type DG units. The proposed strategy is based on the rate of change of reactive power and load connecting strategy to detect islanding within the system. For a large power mismatch, islanding is detected by rate of change of reactive power only. However, for a close power mismatch, the rate of change of reactive power initiates a load connecting strategy, which in turn alters the load on the distribution network. This load variation in the distribution network causes a variation in the rate of change of reactive power, which is utilized to distinguish islanding and other events. The simulation results show that the proposed strategy is effective in detecting islanding occurrence in a distribution network

  2. Mobile Anomaly Detection Based on Improved Self-Organizing Maps

    Directory of Open Access Journals (Sweden)

    Chunyong Yin

    2017-01-01

    Full Text Available Anomaly detection has always been the focus of researchers and especially, the developments of mobile devices raise new challenges of anomaly detection. For example, mobile devices can keep connection with Internet and they are rarely turned off even at night. This means mobile devices can attack nodes or be attacked at night without being perceived by users and they have different characteristics from Internet behaviors. The introduction of data mining has made leaps forward in this field. Self-organizing maps, one of famous clustering algorithms, are affected by initial weight vectors and the clustering result is unstable. The optimal method of selecting initial clustering centers is transplanted from K-means to SOM. To evaluate the performance of improved SOM, we utilize diverse datasets and KDD Cup99 dataset to compare it with traditional one. The experimental results show that improved SOM can get higher accuracy rate for universal datasets. As for KDD Cup99 dataset, it achieves higher recall rate and precision rate.

  3. Enhanced detection rate of typhoid fever among clinically suspected patients in a tertiary referral hospital in Dhaka, Bangladesh using nested polymerase chain reaction technology.

    Science.gov (United States)

    Khan, S; Miah, M R; Khatun, S

    2015-12-01

    A nested polymerase chain reaction (PCR) specific for Salmonella enterica subspecies enteric serovar Typhi was used for the detection of the pathogen, in blood. This study was done during the period of March 2013 to February 2014. A total of 80 clinically suspected cases of typhoid fever were included in the study. Blood was collected from all participating individuals. Nested PCR targeting the flagellin gene (fliC) of Salmonella Typhi & blood culture were done for each of the cases. The positivity rate of PCR & blood culture was 70%& 20% respectively. The positivity rate of PCR was significantly higher than blood culture (Ptyphoid fever cases on the basis of clinical features but with negative cultures. We conclude that the PCR technique could be used as a novel diagnostic method of typhoid fever, particularly in culture-negative cases in an endemic country like Bangladesh.

  4. Topic-oriented community detection of rating-based social networks

    Directory of Open Access Journals (Sweden)

    Ali Reihanian

    2016-07-01

    Full Text Available Nowadays, real world social networks contain a vast range of information including shared objects, comments, following information, etc. Finding meaningful communities in this kind of networks is an interesting research area and has attracted the attention of many researchers. The community structure of complex networks reveals both their organization and hidden relations among their constituents. Most of the researches in the field of community detection mainly focus on the topological structure of the network without performing any content analysis. In recent years, a number of researches have proposed approaches which consider both the contents that are interchanged in networks, and the topological structures of the networks in order to find more meaningful communities. In this research, the effect of topic analysis in finding more meaningful communities in social networking sites in which the users express their feelings toward different objects (like movies by means of rating is demonstrated by performing extensive experiments.

  5. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Energy Technology Data Exchange (ETDEWEB)

    Starkenburg, Daken J. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Johns, Paul M. [Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Detection Systems Group, Pacific Northwest National Laboratory, Richland, Washington 99354, USA; Baciak, James E. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Nino, Juan C. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Xue, Jiangeng [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA

    2017-12-14

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  6. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Science.gov (United States)

    Starkenburg, Daken J.; Johns, Paul M.; Baciak, James E.; Nino, Juan C.; Xue, Jiangeng

    2017-12-01

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.18 μGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  7. Influence of depth, time and human activity on detection rate of acoustic tags: a case study on two fish farms.

    Science.gov (United States)

    Otterå, H; Skilbrei, O T

    2016-03-01

    The detection rates of stationary acoustic transmitters deployed at three depths on two Atlantic salmon Salmo salar cage farms for c. 2 months were investigated. Deployment depth, time of day, day of the year and specific incidences at the farm substantially affected the rate of signal detection by the receiver. © 2016 The Authors. Journal of Fish Biology published by John Wiley & Sons Ltd on behalf of The Fisheries Society of the British Isles.

  8. Probabilistic pipe fracture evaluations for applications to leak-rate detection

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, S; Wilkowski, G; Ghadiali, N [Battelle Columbus Labs., OH (United States)

    1993-12-31

    Stochastic pipe fracture evaluations are conducted for applications to leak-rate detection. A state-of-the-art review was first conducted to evaluate the adequacy of current deterministic models for thermo-hydraulic and elastic-plastic fracture analyses. Then a new probabilistic model was developed with the above deterministic models for structural reliability analysis of cracked piping systems and statistical characterization of crack morphology parameters, material properties of pipe, and crack location. The proposed models are then applied for computing conditional probability of failure for various nuclear piping systems in BWR and PWR plants. The PRAISE code was not used, and the probabilistic model is based on modern methods of stochastic mechanics, computationally far superior to Monte Carlo and Stratified Sampling methods used in PRAISE. 10 refs., 9 figs., 1 tab.

  9. Probabilistic pipe fracture evaluations for applications to leak-rate detection

    International Nuclear Information System (INIS)

    Rahman, S.; Wilkowski, G.; Ghadiali, N.

    1992-01-01

    Stochastic pipe fracture evaluations are conducted for applications to leak-rate detection. A state-of-the-art review was first conducted to evaluate the adequacy of current deterministic models for thermo-hydraulic and elastic-plastic fracture analyses. Then a new probabilistic model was developed with the above deterministic models for structural reliability analysis of cracked piping systems and statistical characterization of crack morphology parameters, material properties of pipe, and crack location. The proposed models are then applied for computing conditional probability of failure for various nuclear piping systems in BWR and PWR plants. The PRAISE code was not used, and the probabilistic model is based on modern methods of stochastic mechanics, computationally far superior to Monte Carlo and Stratified Sampling methods used in PRAISE. 10 refs., 9 figs., 1 tab

  10. [sup 99m]Tc-RBC subtraction scintigraphy; Assessmet of bleeding site and rate

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1994-03-01

    Sequential abdominal scintigrams with [sup 99m]Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author).

  11. Effect of additives for higher removal rate in lithium niobate chemical mechanical planarization

    International Nuclear Information System (INIS)

    Jeong, Sukhoon; Lee, Hyunseop; Cho, Hanchul; Lee, Sangjik; Kim, Hyoungjae; Kim, Sungryul; Park, Jaehong; Jeong, Haedo

    2010-01-01

    High roughness and a greater number of defects were created by lithium niobate (LN; LiNbO 3 ) processes such as traditional grinding and mechanical polishing (MP), should be decreased for manufacturing LN device. Therefore, an alternative process for gaining defect-free and smooth surface is needed. Chemical mechanical planarization (CMP) is suitable method in the LN process because it uses a combination approach consisting of chemical and mechanical effects. First of all, we investigated the LN CMP process using commercial slurry by changing various process conditions such as down pressure and relative velocity. However, the LN CMP process time using commercial slurry was long to gain a smooth surface because of lower material removal rate (MRR). So, to improve the material removal rate (MRR), the effects of additives such as oxidizer (hydrogen peroxide; H 2 O 2 ) and complexing agent (citric acid; C 6 H 8 O 7 ) in a potassium hydroxide (KOH) based slurry, were investigated. The manufactured slurry consisting of H 2 O 2 -citric acid in the KOH based slurry shows that the MRR of the H 2 O 2 at 2 wt% and the citric acid at 0.06 M was higher than the MRR for other conditions.

  12. Heroin and cocaine abusers have higher discount rates for delayed rewards than alcoholics or non-drug-using controls.

    Science.gov (United States)

    Kirby, Kris N; Petry, Nancy M

    2004-04-01

    To test a prediction of the discounting model of impulsiveness that discount rates would be positively associated with addiction. The delay-discount rate refers to the rate of reduction in the present value of a future reward as the delay to that reward increases. We estimated participants' discount rates on the basis of their pattern of choices between smaller immediate rewards ($11-80) and larger, delayed rewards ($25-85; at delays from 1 week to 6 months) in a questionnaire format. Participants had a one-in-six chance of winning a reward that they chose on one randomly selected trial. Heroin (n = 27), cocaine (n = 41) and alcohol (n = 33) abusers and non-drug-using controls (n = 44) were recruited from advertisements. They were tested in a drug abuse research clinic at a medical school. On average, the cocaine and heroin groups had higher rates than controls (both P rates for heroin abusers (P = 0.03), but not for cocaine or alcohol abusers (both P > 0.50). These data suggest that discount rates vary with the preferred drug of abuse, and that high discount rates should be considered in the development of substance abuse prevention and treatment efforts.

  13. Astrophysical limitations to the identification of dark matter: Indirect neutrino signals vis-a-vis direct detection recoil rates

    International Nuclear Information System (INIS)

    Serpico, Pasquale D.; Bertone, Gianfranco

    2010-01-01

    A convincing identification of dark matter (DM) particles can probably be achieved only through a combined analysis of different detections strategies, which provides an effective way of removing degeneracies in the parameter space of DM models. In practice, however, this program is made complicated by the fact that different strategies depend on different physical quantities, or on the same quantities but in a different way, making the treatment of systematic errors rather tricky. We discuss here the uncertainties on the recoil rate in direct-detection experiments and on the muon rate induced by neutrinos from dark matter annihilations in the Sun, and we show that, contrarily to the local DM density or overall cross section scale, irreducible astrophysical uncertainties affect the two rates in a different fashion, therefore limiting our ability to reconstruct the parameters of the dark matter particles. By varying within their respective errors astrophysical parameters such as the escape velocity and the velocity dispersion of dark matter particles, we show that the uncertainty on the relative strength of the neutrino and direct-detection signal is as large as a factor of 2 for typical values of the parameters, but can be even larger in some circumstances.

  14. Higher Growth Rate of Branch Duct Intraductal Papillary Mucinous Neoplasms Associates With Worrisome Features.

    Science.gov (United States)

    Kolb, Jennifer M; Argiriadi, Pamela; Lee, Karen; Liu, Xiaoyu; Bagiella, Emilia; Lucas, Aimee L; Kim, Michelle Kang; Kumta, Nikhil A; Nagula, Satish; Sarpel, Umut; DiMaio, Christopher J

    2018-03-11

    or invasive cancers. BD-IPMNs that developed worrisome features were associated with a significantly higher rate of growth than lesions with low-risk features. Low risk BD-IPMNs that grow more than 2.5 mm/year might require surveillance. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  15. Evaluating cessation of the type 2 oral polio vaccine by modeling pre- and post-cessation detection rates.

    Science.gov (United States)

    Kroiss, Steve J; Famulare, Michael; Lyons, Hil; McCarthy, Kevin A; Mercer, Laina D; Chabot-Couture, Guillaume

    2017-10-09

    The globally synchronized removal of the attenuated Sabin type 2 strain from the oral polio vaccine (OPV) in April 2016 marked a major change in polio vaccination policy. This change will provide a significant reduction in the burden of vaccine-associated paralytic polio (VAPP), but may increase the risk of circulating vaccine-derived poliovirus (cVDPV2) outbreaks during the transition period. This risk can be monitored by tracking the disappearance of Sabin-like type 2 (SL2) using data from the polio surveillance system. We studied SL2 prevalence in 17 countries in Africa and Asia, from 2010 to 2016 using acute flaccid paralysis surveillance data. We modeled the peak and decay of SL2 prevalence following mass vaccination events using a beta-binomial model for the detection rate, and a Ricker function for the temporal dependence. We found type 2 circulated the longest of all serotypes after a vaccination campaign, but that SL2 prevalence returned to baseline levels in approximately 50days. Post-cessation model predictions identified 19 anomalous SL2 detections outside of model predictions in Afghanistan, India, Nigeria, Pakistan, and western Africa. Our models established benchmarks for the duration of SL2 detection after OPV2 cessation. As predicted, SL2 detection rates have plummeted, except in Nigeria where OPV2 use continued for some time in response to recent cVDPV2 detections. However, the anomalous SL2 detections suggest specific areas that merit enhanced monitoring for signs of cVDPV2 outbreaks. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Analysis of acoustic cardiac signals for heart rate variability and murmur detection using nonnegative matrix factorization-based hierarchical decomposition

    DEFF Research Database (Denmark)

    Shah, Ghafoor; Koch, Peter; Papadias, Constantinos B.

    2014-01-01

    The detection of heart rate variability (HRV) via cardiac auscultation examination can be a useful and inexpensive tool which, however, is challenging in the presence of pathological signals and murmurs. The aim of this research is to analyze acoustic cardiac signals for HRV and murmur detection...

  17. Is interstellar detection of higher members of the linear radicals CnCH and CnN feasible?

    Science.gov (United States)

    Pauzat, F.; Ellinger, Y.; Mclean, A. D.

    1991-01-01

    Rotational constants and dipole moments for linear-chain radicals CnCH and CnN are estimated using a combinatiaon of ab initio molecular orbital calculations and observed data on the starting members of the series. CnCH with n = 0-5 have been observed by radioastronomy in carbon-rich interstellar clouds; higher members of the series have 2Pi ground states with large dipole moments and are strong candidates for observation. CN and C3N have also been observed by radioastronomy; higher members of the series, with the possible exception of C5N, have 2Pi ground states with near-zero dipole moments making their interstellar detection hopeless under present observational conditions. C5N can be a strong candidate only if it has a 2Sigma ground state, and best computations so far indicate that this is not the case.

  18. Concurrent Detection of Human Norovirus and Bacterial Pathogens in Water Samples from an Agricultural Region in Central California Coast

    Directory of Open Access Journals (Sweden)

    Peng Tian

    2017-08-01

    Full Text Available Bacterial pathogens and human norovirus (HuNoV are major cause for acute gastroenteritis caused by contaminated food and water. Public waterways can become contaminated from a variety of sources and flood after heavy rain events, leading to pathogen contamination of produce fields. We initiated a survey of several public watersheds in a major leafy green produce production region of the Central California Coast to determine the prevalence of HuNoV as well as bacterial pathogens. Moore swabs were used to collect environmental samples bi-monthly at over 30 sampling sites in the region. High prevalence of HuNoV and bacterial pathogens were detected in environmental water samples in the region. The overall detection rates of HuNoV, O157 Shiga toxin-producing Escherichia coli (STEC, non-O157 STEC, Salmonella, and Listeria were 25.58, 7.91, 9.42, 59.65, and 44.30%, respectively. The detection rates of Salmonella and L. monocytogenes were significantly higher in the spring. Fall and spring had elevated detection rates of O157 STEC. The overall detection rates of non-O157 STEC in the fall were lower than the other seasons but not significant. The overall detection rates of HuNoV were highest in fall, followed by spring and winter, with summer being lowest and significantly lower than other seasons. This study presented the first study of evaluating the correlation between the detection rate of HuNoV and the detection rates of four bacterial pathogens from environmental water. Overall, there was no significant difference in HuNoV detection rates between samples testing positive or negative for the four bacterial pathogens tested. Pathogens in animal-impacted and human-impacted areas were investigated. There were significant higher detection rates in animal-impacted areas than that of human-impacted areas for bacterial pathogens. However, there was no difference in HuNoV detection rates between these two areas. The overall detection levels of generic E

  19. Student Ratings of Instruction in Turkish Higher Education

    Directory of Open Access Journals (Sweden)

    Nehir Sert

    2013-05-01

    Full Text Available The end-of-term student evaluations have a twofold purpose: to provide information for administrators to make personnel decisions, and to help instructors to improve the quality of their teaching. The aim of this study is to investigate the ‘utility’ of the Student Ratings of Instruction (SRI. To that end, the concerns of the administrators, instructors and students regarding the use of the SRI in formative and summative evaluations are questioned. This study also investigates possible variables associated with the SRI: 1 what are the differences in ratings among the below-average, average and the above-average students? and 2 what is the correlation between the students’ grades and ratings? The participants of the study consisted of 5 administrators, 17 instructors and 292 students from the faculty of education of a foundation university in Ankara. A triangulation of quantitative and qualitative methods was adopted. In the first phase, causal comparative and correlation research methods were implemented. In the second phase, qualitative data were collected through semi-structured interviews. The results revealed that there was no significant difference in the SRI among the below-average, average and above-average students. The correlation between the student grades and the SRI was significant at a low level. The SRI were reportedly utilised to make teaching more effective and to make decisions when employing part-time personnel only. The permanent personnel were not affected by the SRI. Suggestions have been put forward to verify the usefulness of SRI.

  20. Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

    Directory of Open Access Journals (Sweden)

    M. J. Abbasi

    2016-12-01

    Full Text Available The doubly fed induction generator (DFIG is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE event is among the most frequent failures in electric generators. However, LOE detection studies heretofore were usually confined to synchronous generators. Common LOE detection methods are based on impedance trajectory which makes the system slow and also prone to interpret a stable power swing (SPS as a LOE fault. This paper suggests a new method to detect the LOE based on the measured variables from the DFIG terminal. In this combined method for LOE detection, the rate of change of both the terminal voltage and the output reactive power are utilized and for SPS detection, the fast Fourier transform (FFT analysis of the output instantaneous active power has been used. The performance of the proposed method was evaluated using Matlab/Simulink interface for various power capacities and operating conditions. The results proved the method's quickness, simplicity and security.

  1. Design of stepwise screening for prediabetes and type 2 diabetes based on costs and cases detected.

    Science.gov (United States)

    de Graaf, Gimon; Postmus, Douwe; Bakker, Stephan J L; Buskens, Erik

    2015-09-01

    To provide insight into the trade-off between cost per case detected (CPCD) and the detection rate in questionnaire-based stepwise screening for impaired fasting glucose and undiagnosed type 2 diabetes. We considered a stepwise screening in which individuals whose risk score exceeds a predetermined cutoff value are invited for further blood glucose testing. Using individual patient data to determine questionnaire sensitivity and specificity and external sources to determine screening costs and patient response rates, we rolled back a decision tree to estimate the CPCD and the detection rate for all possible cutoffs on the questionnaire. We found a U-shaped relation between CPCD and detection rate, with high costs per case detected at very low and very high detection rates. Changes in patient response rates had a large impact on both the detection rate and the CPCD, whereas screening costs and questionnaire accuracy mainly impacted the CPCD. Our applied method makes it possible to identify a range of efficient cutoffs where higher detection rates can be achieved at an additional cost per detected patient. This enables decision makers to choose an optimal cutoff based on their willingness to pay for additional detected patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Cardiac arrhythmia detection using combination of heart rate variability analyses and PUCK analysis.

    Science.gov (United States)

    Mahananto, Faizal; Igasaki, Tomohiko; Murayama, Nobuki

    2013-01-01

    This paper presents cardiac arrhythmia detection using the combination of a heart rate variability (HRV) analysis and a "potential of unbalanced complex kinetics" (PUCK) analysis. Detection performance was improved by adding features extracted from the PUCK analysis. Initially, R-R interval data were extracted from the original electrocardiogram (ECG) recordings and were cut into small segments and marked as either normal or arrhythmia. HRV analyses then were conducted using the segmented R-R interval data, including a time-domain analysis, frequency-domain analysis, and nonlinear analysis. In addition to the HRV analysis, PUCK analysis, which has been implemented successfully in a foreign exchange market series to characterize change, was employed. A decision-tree algorithm was applied to all of the obtained features for classification. The proposed method was tested using the MIT-BIH arrhythmia database and had an overall classification accuracy of 91.73%. After combining features obtained from the PUCK analysis, the overall accuracy increased to 92.91%. Therefore, we suggest that the use of a PUCK analysis in conjunction with HRV analysis might improve performance accuracy for the detection of cardiac arrhythmia.

  3. Exploiting Academic Records for Predicting Student Drop Out: a case study in Brazilian higher education

    OpenAIRE

    Sales, Allan; Balby, Leandro; Cajueiro, Adalberto

    2017-01-01

    Students’ dropout is a major concern of the Brazilian higher education institutions as it may cause waste of resources and decrease graduation rates. The early detection of students with high probability of dropping out, as well as understanding the underlying causes, are crucial for defining more effective actions toward preventing this problem. In this paper, we cast the dropout detection problem as a classification problem. We use a large sample of academic records of students across 76 co...

  4. Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices.

    Science.gov (United States)

    Gambi, Ennio; Agostinelli, Angela; Belli, Alberto; Burattini, Laura; Cippitelli, Enea; Fioretti, Sandro; Pierleoni, Paola; Ricciuti, Manola; Sbrollini, Agnese; Spinsante, Susanna

    2017-08-02

    Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects' normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject's lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account.

  5. Measurement of radiocesium concentration in trees using cumulative gamma radiation dose rate detection systems - A simple presumption for radiocesium concentration in living woods using glass-badge based gamma radiation dose rate detection system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, T.; Hashida, S.N. [Plant Molecular Biology, Laboratory of Environmental Science, Central Research Institute of Electric Power Industry (CRIEPI), 1646 Abiko, Chiba 270-1194 (Japan); Kawachi, N.; Suzui, N.; Yin, Y.G.; Fujimaki, S. [Radiotracer Imaging Gr., Quantum Beam Science Center, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagao, Y.; Yamaguchi, M. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-07-01

    Radiocesium from the severe accident at the Fukushima Dai-ichi Nuclear Power Plant on 11 March 2011 contaminates large areas. After this, a doubt for forest products, especially of mushroom, is indelible at the areas. Pruned woody parts and litters are containing a considerable amount of radiocesium, and generates a problem at incineration and composting. These mean that more attentive survey for each subject is expected; however, the present survey system is highly laborious/expensive and/or non-effective for this purpose. On the other hand, we can see a glass-badge based gamma radiation dose rate detection system. This system always utilized to detect a personal cumulative radiation dose, and thus, it is not suitable to separate a radiation from a specific object. However, if we can separate a radiation from a specific object and relate it with the own radiocesium concentration, it would enable us to presume the specific concentration with just an easy monitoring but without a destruction of the target nature and a complicated process including sampling, pre-treatment, and detection. Here, we present the concept of the measurement and results of the trials. First, we set glass-badges (type FS, Chiyoda Technol Corp., Japan) on a part of bough (approximately 10 cm in diameter) of Japanese flowering cherry trees (Prunus x yedoensis cv. Somei-Yoshino) with four different settings: A, a direct setting without any shield; B, a setting with an aluminum shield between bough and the glass-badge; C, a setting with a lead shield between bough and the glass-badge; D, a setting with a lead shield covering the glass-badge to shut the radiation from the surrounding but from bough. The deduction between the amount of each setting should separate a specific radiation of the bough from unlimited radiation from the surrounding. Even if the hourly dose rate is not enough to count the difference, a moderate cumulative dose would clear the difference. In fact, results demonstrated a

  6. Using field feedback to estimate failure rates of safety-related systems

    International Nuclear Information System (INIS)

    Brissaud, Florent

    2017-01-01

    The IEC 61508 and IEC 61511 functional safety standards encourage the use of field feedback to estimate the failure rates of safety-related systems, which is preferred than generic data. In some cases (if “Route 2_H” is adopted for the 'hardware safety integrity constraints”), this is even a requirement. This paper presents how to estimate the failure rates from field feedback with confidence intervals, depending if the failures are detected on-line (called 'detected failures', e.g. by automatic diagnostic tests) or only revealed by proof tests (called 'undetected failures'). Examples show that for the same duration and number of failures observed, the estimated failure rates are basically higher for “undetected failures” because, in this case, the duration observed includes intervals of time where it is unknown that the elements have failed. This points out the need of using a proper approach for failure rates estimation, especially for failures that are not detected on-line. Then, this paper proposes an approach to use the estimated failure rates, with their uncertainties, for PFDavg and PFH assessment with upper confidence bounds, in accordance with IEC 61508 and IEC 61511 requirements. Examples finally show that the highest SIL that can be claimed for a safety function can be limited by the 90% upper confidence bound of PFDavg or PFH. The requirements of the IEC 61508 and IEC 61511 relating to the data collection and analysis should therefore be properly considered for the study of all safety-related systems. - Highlights: • This paper deals with requirements of the IEC 61508 and IEC 61511 for using field feedback to estimate failure rates of safety-related systems. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are detected on-line. • This paper presents how to estimate the failure rates from field feedback with confidence intervals for failures that are only revealed by

  7. Time of day variation in polyp detection rate for colonoscopies performed on a 3-hour shift schedule.

    LENUS (Irish Health Repository)

    Munson, Gregory W

    2011-03-01

    Recent research suggests that the colonoscopy polyp detection rate (PDR) varies by time of day, possibly because of endoscopist fatigue. Mayo Clinic Rochester (MCR) schedules colonoscopies on 3-hour shifts, which should minimize fatigue.

  8. THE DETECTION RATE OF EARLY UV EMISSION FROM SUPERNOVAE: A DEDICATED GALEX/PTF SURVEY AND CALIBRATED THEORETICAL ESTIMATES

    Energy Technology Data Exchange (ETDEWEB)

    Ganot, Noam; Gal-Yam, Avishay; Ofek, Eran O.; Sagiv, Ilan; Waxman, Eli; Lapid, Ofer [Department of Particle Physics and Astrophysics, Faculty of Physics, The Weizmann Institute of Science, Rehovot 76100 (Israel); Kulkarni, Shrinivas R.; Kasliwal, Mansi M. [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Ben-Ami, Sagi [Smithsonian Astrophysical Observatory, Harvard-Smithsonian Ctr. for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Chelouche, Doron; Rafter, Stephen [Physics Department, Faculty of Natural Sciences, University of Haifa, 31905 Haifa (Israel); Behar, Ehud; Laor, Ari [Physics Department, Technion Israel Institute of Technology, 32000 Haifa (Israel); Poznanski, Dovi; Nakar, Ehud; Maoz, Dan [School of Physics and Astronomy, Tel Aviv University, 69978 Tel Aviv (Israel); Trakhtenbrot, Benny [Institute for Astronomy, ETH Zurich, Wolfgang-Pauli-Strasse 27 Zurich 8093 (Switzerland); Neill, James D.; Barlow, Thomas A.; Martin, Christofer D., E-mail: noam.ganot@gmail.com [California Institute of Technology, 1200 East California Boulevard, MC 278-17, Pasadena, CA 91125 (United States); Collaboration: ULTRASAT Science Team; WTTH consortium; GALEX Science Team; Palomar Transient Factory; and others

    2016-03-20

    The radius and surface composition of an exploding massive star, as well as the explosion energy per unit mass, can be measured using early UV observations of core-collapse supernovae (SNe). We present the first results from a simultaneous GALEX/PTF search for early ultraviolet (UV) emission from SNe. Six SNe II and one Type II superluminous SN (SLSN-II) are clearly detected in the GALEX near-UV (NUV) data. We compare our detection rate with theoretical estimates based on early, shock-cooling UV light curves calculated from models that fit existing Swift and GALEX observations well, combined with volumetric SN rates. We find that our observations are in good agreement with calculated rates assuming that red supergiants (RSGs) explode with fiducial radii of 500 R{sub ⊙}, explosion energies of 10{sup 51} erg, and ejecta masses of 10 M{sub ⊙}. Exploding blue supergiants and Wolf–Rayet stars are poorly constrained. We describe how such observations can be used to derive the progenitor radius, surface composition, and explosion energy per unit mass of such SN events, and we demonstrate why UV observations are critical for such measurements. We use the fiducial RSG parameters to estimate the detection rate of SNe during the shock-cooling phase (<1 day after explosion) for several ground-based surveys (PTF, ZTF, and LSST). We show that the proposed wide-field UV explorer ULTRASAT mission is expected to find >85 SNe per year (∼0.5 SN per deg{sup 2}), independent of host galaxy extinction, down to an NUV detection limit of 21.5 mag AB. Our pilot GALEX/PTF project thus convincingly demonstrates that a dedicated, systematic SN survey at the NUV band is a compelling method to study how massive stars end their life.

  9. Reaction rate constant of HO2+O3 measured by detecting HO2 from photofragment fluorescence

    Science.gov (United States)

    Manzanares, E. R.; Suto, Masako; Lee, Long C.; Coffey, Dewitt, Jr.

    1986-01-01

    A room-temperature discharge-flow system investigation of the rate constant for the reaction 'HO2 + O3 yields OH + 2O2' has detected HO2 through the OH(A-X) fluorescence produced by photodissociative excitation of HO2 at 147 nm. A reaction rate constant of 1.9 + or - 0.3 x 10 to the -15th cu cm/molecule per sec is obtained from first-order decay of HO2 in excess O3; this agrees well with published data.

  10. Study of higher hydrocarbon production during ethylacetylene pyrolysis using laser-generated vacuum-ultraviolet photoionization detection

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J.; Pfefferle, L. (Yale Univ., New Haven, CT (USA))

    1990-04-19

    Higher hydrocarbon formation during the pyrolysis of ethylacetylene in a microjet reactor was studied by vacuum-ultraviolet photoionization time-of-flight mass spectrometry. At the wavelength employed, this ionization technique allows for the simultaneous detection of both stable and intermediate polyatomic species with ionization potentials below 10.49 eV, including most hydrocarbons with two or more carbon atoms. Minimal fragmentation simplifies the determination of parent species and allows identification of probable reaction pathways involving hydrocarbon radicals as well as stable species. The pyrolysis of ethylacetylene was carried out in the fast-flow microjet reactor (residence times 1-2 ms) at temperatures from 300 to 1,600 K.

  11. Is interstellar detection of higher members of the linear radicals CnCH and CnN feasible?

    International Nuclear Information System (INIS)

    Pauzat, F.; Ellinger, Y.; Mclean, A.D.

    1991-01-01

    Rotational constants and dipole moments for linear-chain radicals CnCH and CnN are estimated using a combinatiaon of ab initio molecular orbital calculations and observed data on the starting members of the series. CnCH with n = 0-5 have been observed by radioastronomy in carbon-rich interstellar clouds; higher members of the series have 2Pi ground states with large dipole moments and are strong candidates for observation. CN and C3N have also been observed by radioastronomy; higher members of the series, with the possible exception of C5N, have 2Pi ground states with near-zero dipole moments making their interstellar detection hopeless under present observational conditions. C5N can be a strong candidate only if it has a 2Sigma ground state, and best computations so far indicate that this is not the case. 20 refs

  12. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  13. Rating the Effectiveness of Fishery Closures With Visible Infrared Imaging Radiometer Suite Boat Detection Data

    Directory of Open Access Journals (Sweden)

    Christopher D. Elvidge

    2018-04-01

    Full Text Available Fishery closures are widely used to promote the sustainability of fish stocks. Fishery agencies typically have very little data relevant to planning closure enforcement actions and evaluating the effectiveness of closures, due in part to the vast expanse and remote nature of many closures. In some cases the effectiveness of closures can be evaluated using data from GPS based beacons, such as Automatic Identification System (AIS or Vessel Monitoring Systems (VMS installed on fishing boats. In fisheries where few boats are equipped with AIS or VMS, the rating of closures relies on other data sources capable of detecting or inferring fishing activity. One such source comes from low light imaging data collected by the NASA/NOAA Visible Infrared Imaging Radiometer Suite (VIIRS, which can detect fishing boats using lights to attract catch. This is a widely used practice in Asia and several other regions. NOAA has developed an automatic system for reporting the locations of VIIRS boat detections with a nominal 4 h temporal latency. VIIRS boat detection alerts are running for more than 900 fishery closures in the Philippines, with email and SMS transmission modes. These alerts are being actively used in the Philippines to plan enforcement actions and there is a growing list of apprehensions that occurred based on tip-offs from VIIRS. The VIIRS boat detection archive extends back to April 2012. A VIIRS closure index (VCI has been developed to rate the effectiveness of closures on monthly increments in terms of a percentage. The VCI analysis was performed on three types of closures: an ad hoc fishery closure associated with a toxic industrial discharge, a seasonal fishery closure and a permanent closure in restricted coastal waters. The VCI results indicate that it is possible to rank the effectiveness of different closure, year-to-year differences in compliance levels, and to identify closure encroachments which may warrant additional enforcement effort.

  14. Molecular Detection of the Carriage Rate of Four Intestinal Protozoa with Real-Time Polymerase Chain Reaction: Possible Overdiagnosis of Entamoeba histolytica in Nigeria.

    Science.gov (United States)

    Efunshile, Michael A; Ngwu, Bethrand A F; Kurtzhals, Jørgen A L; Sahar, Sumrin; König, Brigitte; Stensvold, Christen R

    2015-08-01

    Diarrhea remains the second largest killer of children worldwide, and Nigeria ranks number two on the list of global deaths attributable to diarrhea. Meanwhile, prevalence studies on potentially diarrheagenic protozoa in asymptomatic carriers using molecular detection methods remain scarce in sub-Saharan countries. To overcome sensitivity issues related to microscopic detection and identification of cysts in stool concentrates, real-time polymerase chain reaction (PCR) was used to analyze genomic DNAs extracted from stool samples from 199 healthy school children for Entamoeba histolytica, E. dispar, Giardia intestinalis, and Cryptosporidium. Questionnaires were administered for epidemiological data collection. E. histolytica was not detected in any of the samples, whereas Giardia (37.2%), E. dispar (18.6%), and Cryptosporidium (1%) were found. Most of the children sourced their drinking water from community wells (91%), while the majority disposed of feces in the bush (81.9%). Our study is the first to use real-time PCR to evaluate the epidemiology of E. histolytica, Giardia, and Cryptosporidium in Nigeria where previous studies using traditional diagnostic techniques have suggested higher and lower carriage rates of E. histolytica and Giardia, respectively. It is also the first study to accurately identify the prevalence of common potentially diarrheagenic protozoa in asymptomatic carriers in sub-Saharan Africa. © The American Society of Tropical Medicine and Hygiene.

  15. CFAR Detection from Noncoherent Radar Echoes Using Bayesian Theory

    Directory of Open Access Journals (Sweden)

    Wataru Suganuma

    2010-01-01

    Full Text Available We propose a new constant false alarm rate (CFAR detection method from noncoherent radar echoes, considering heterogeneous sea clutter. It applies the Bayesian theory for adaptive estimation of the local clutter statistical distribution in the cell under test. The detection technique can be readily implemented in existing noncoherent marine radar systems, which makes it particularly attractive for economical CFAR detection systems. Monte Carlo simulations were used to investigate the detection performance and demonstrated that the proposed technique provides a higher probability of detection than conventional techniques, such as cell averaging CFAR (CA-CFAR, especially with a small number of reference cells.

  16. CFAR Detection from Noncoherent Radar Echoes Using Bayesian Theory

    Directory of Open Access Journals (Sweden)

    Yamaguchi Hiroyuki

    2010-01-01

    Full Text Available Abstract We propose a new constant false alarm rate (CFAR detection method from noncoherent radar echoes, considering heterogeneous sea clutter. It applies the Bayesian theory for adaptive estimation of the local clutter statistical distribution in the cell under test. The detection technique can be readily implemented in existing noncoherent marine radar systems, which makes it particularly attractive for economical CFAR detection systems. Monte Carlo simulations were used to investigate the detection performance and demonstrated that the proposed technique provides a higher probability of detection than conventional techniques, such as cell averaging CFAR (CA-CFAR, especially with a small number of reference cells.

  17. Non-contact acquisition of respiration and heart rates using Doppler radar with time domain peak-detection algorithm.

    Science.gov (United States)

    Xiaofeng Yang; Guanghao Sun; Ishibashi, Koichiro

    2017-07-01

    The non-contact measurement of the respiration rate (RR) and heart rate (HR) using a Doppler radar has attracted more attention in the field of home healthcare monitoring, due to the extremely low burden on patients, unconsciousness and unconstraint. Most of the previous studies have performed the frequency-domain analysis of radar signals to detect the respiration and heartbeat frequency. However, these procedures required long period time (approximately 30 s) windows to obtain a high-resolution spectrum. In this study, we propose a time-domain peak detection algorithm for the fast acquisition of the RR and HR within a breathing cycle (approximately 5 s), including inhalation and exhalation. Signal pre-processing using an analog band-pass filter (BPF) that extracts respiration and heartbeat signals was performed. Thereafter, the HR and RR were calculated using a peak position detection method, which was carried out via LABVIEW. To evaluate the measurement accuracy, we measured the HR and RR of seven subjects in the laboratory. As a reference of HR and RR, the persons wore contact sensors i.e., an electrocardiograph (ECG) and a respiration band. The time domain peak-detection algorithm, based on the Doppler radar, exhibited a significant correlation coefficient of HR of 0.92 and a correlation coefficient of RR of 0.99, between the ECG and respiration band, respectively.

  18. Variable terrestrial GPS telemetry detection rates: Addressing the probability of successful acquisitions

    Science.gov (United States)

    Ironside, Kirsten E.; Mattson, David J.; Choate, David; Stoner, David; Arundel, Terry; Hansen, Jered R.; Theimer, Tad; Holton, Brandon; Jansen, Brian; Sexton, Joseph O.; Longshore, Kathleen M.; Edwards, Thomas C.; Peters, Michael

    2017-01-01

    Studies using global positioning system (GPS) telemetry rarely result in 100% fix success rates (FSR), which may bias datasets because data loss is systematic rather than a random process. Previous spatially explicit models developed to correct for sampling bias have been limited to small study areas, a small range of data loss, or were study-area specific. We modeled environmental effects on FSR from desert to alpine biomes, investigated the full range of potential data loss (0–100% FSR), and evaluated whether animal body position can contribute to lower FSR because of changes in antenna orientation based on GPS detection rates for 4 focal species: cougars (Puma concolor), desert bighorn sheep (Ovis canadensis nelsoni), Rocky Mountain elk (Cervus elaphus nelsoni), and mule deer (Odocoileus hemionus). Terrain exposure and height of over story vegetation were the most influential factors affecting FSR. Model evaluation showed a strong correlation (0.88) between observed and predicted FSR and no significant differences between predicted and observed FSRs using 2 independent validation datasets. We found that cougars and canyon-dwelling bighorn sheep may select for environmental features that influence their detectability by GPS technology, mule deer may select against these features, and elk appear to be nonselective. We observed temporal patterns in missed fixes only for cougars. We provide a model for cougars, predicting fix success by time of day that is likely due to circadian changes in collar orientation and selection of daybed sites. We also provide a model predicting the probability of GPS fix acquisitions given environmental conditions, which had a strong relationship (r 2 = 0.82) with deployed collar FSRs across species.

  19. Nonlinear Heart Rate Variability features for real-life stress detection. Case study: students under stress due to university examination.

    Science.gov (United States)

    Melillo, Paolo; Bracale, Marcello; Pecchia, Leandro

    2011-11-07

    This study investigates the variations of Heart Rate Variability (HRV) due to a real-life stressor and proposes a classifier based on nonlinear features of HRV for automatic stress detection. 42 students volunteered to participate to the study about HRV and stress. For each student, two recordings were performed: one during an on-going university examination, assumed as a real-life stressor, and one after holidays. Nonlinear analysis of HRV was performed by using Poincaré Plot, Approximate Entropy, Correlation dimension, Detrended Fluctuation Analysis, Recurrence Plot. For statistical comparison, we adopted the Wilcoxon Signed Rank test and for development of a classifier we adopted the Linear Discriminant Analysis (LDA). Almost all HRV features measuring heart rate complexity were significantly decreased in the stress session. LDA generated a simple classifier based on the two Poincaré Plot parameters and Approximate Entropy, which enables stress detection with a total classification accuracy, a sensitivity and a specificity rate of 90%, 86%, and 95% respectively. The results of the current study suggest that nonlinear HRV analysis using short term ECG recording could be effective in automatically detecting real-life stress condition, such as a university examination.

  20. How Well Can We Detect Lineage-Specific Diversification-Rate Shifts? A Simulation Study of Sequential AIC Methods.

    Science.gov (United States)

    May, Michael R; Moore, Brian R

    2016-11-01

    Evolutionary biologists have long been fascinated by the extreme differences in species numbers across branches of the Tree of Life. This has motivated the development of statistical methods for detecting shifts in the rate of lineage diversification across the branches of phylogenic trees. One of the most frequently used methods, MEDUSA, explores a set of diversification-rate models, where each model assigns branches of the phylogeny to a set of diversification-rate categories. Each model is first fit to the data, and the Akaike information criterion (AIC) is then used to identify the optimal diversification model. Surprisingly, the statistical behavior of this popular method is uncharacterized, which is a concern in light of: (1) the poor performance of the AIC as a means of choosing among models in other phylogenetic contexts; (2) the ad hoc algorithm used to visit diversification models, and; (3) errors that we reveal in the likelihood function used to fit diversification models to the phylogenetic data. Here, we perform an extensive simulation study demonstrating that MEDUSA (1) has a high false-discovery rate (on average, spurious diversification-rate shifts are identified [Formula: see text] of the time), and (2) provides biased estimates of diversification-rate parameters. Understanding the statistical behavior of MEDUSA is critical both to empirical researchers-in order to clarify whether these methods can make reliable inferences from empirical datasets-and to theoretical biologists-in order to clarify the specific problems that need to be solved in order to develop more reliable approaches for detecting shifts in the rate of lineage diversification. [Akaike information criterion; extinction; lineage-specific diversification rates; phylogenetic model selection; speciation.]. © The Author(s) 2016. Published by Oxford University Press, on behalf of the Society of Systematic Biologists.

  1. Hydraulic conductance as well as nitrogen accumulation plays a role in the higher rate of leaf photosynthesis of the most productive variety of rice in Japan.

    Science.gov (United States)

    Taylaran, Renante D; Adachi, Shunsuke; Ookawa, Taiichiro; Usuda, Hideaki; Hirasawa, Tadashi

    2011-07-01

    An indica variety Takanari is known as one of the most productive rice varieties in Japan and consistently produces 20-30% heavier dry matter during ripening than Japanese commercial varieties in the field. The higher rate of photosynthesis of individual leaves during ripening has been recognized in Takanari. By using pot-grown plants under conditions of minimal mutual shading, it was confirmed that the higher rate of leaf photosynthesis is responsible for the higher dry matter production after heading in Takanari as compared with a japonica variety, Koshihikari. The rate of leaf photosynthesis and shoot dry weight became larger in Takanari after the panicle formation and heading stages, respectively, than in Koshihikari. Roots grew rapidly in the panicle formation stage until heading in Takanari compared with Koshihikari. The higher rate of leaf photosynthesis in Takanari resulted not only from the higher content of leaf nitrogen, which was caused by its elevated capacity for nitrogen accumulation, but also from higher stomatal conductance. When measured under light-saturated conditions, stomatal conductance was already decreased due to the reduction in leaf water potential in Koshihikari even under conditions of a relatively small difference in leaf-air vapour pressure difference. In contrast, the higher stomatal conductance was supported by the maintenance of higher leaf water potential through the higher hydraulic conductance in Takanari with the larger area of root surface. However, no increase in root hydraulic conductivity was expected in Takanari. The larger root surface area of Takanari might be a target trait in future rice breeding for increasing dry matter production.

  2. Biodegradation testing of chemicals with high Henry’s constants – separating mass and effective concentration reveals higher rate constants

    DEFF Research Database (Denmark)

    Birch, Heidi; Andersen, Henrik Rasmus; Comber, Mike

    Microextraction (HS-SPME) was applied directly on the test systems to measure substrate depletion by biodegradation relative to abiotic controls. HS-SPME was also applied to determine air to water partitioning ratios. Water phase biodegradation rate constants, kwater, were up to 72 times higher than test system...

  3. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  4. SequenceLDhot: detecting recombination hotspots.

    Science.gov (United States)

    Fearnhead, Paul

    2006-12-15

    There is much local variation in recombination rates across the human genome--with the majority of recombination occurring in recombination hotspots--short regions of around approximately 2 kb in length that have much higher recombination rates than neighbouring regions. Knowledge of this local variation is important, e.g. in the design and analysis of association studies for disease genes. Population genetic data, such as that generated by the HapMap project, can be used to infer the location of these hotspots. We present a new, efficient and powerful method for detecting recombination hotspots from population data. We compare our method with four current methods for detecting hotspots. It is orders of magnitude quicker, and has greater power, than two related approaches. It appears to be more powerful than HotspotFisher, though less accurate at inferring the precise positions of the hotspot. It was also more powerful than LDhot in some situations: particularly for weaker hotspots (10-40 times the background rate) when SNP density is lower (maths.lancs.ac.uk/~fearnhea/Hotspot.

  5. Early detection of left ventricular dysfunction in asymptomatic diabetic patient using strain and strain rate echocardiographic imaging

    Directory of Open Access Journals (Sweden)

    Rania Gaber

    2014-03-01

    Conclusion: Type 2 diabetes mellitus deteriorate both LV systolic and diastolic performance. Strain and strain rate by tissue Doppler Imaging is superior to conventional Doppler in early detection and evaluation of systolic and diastolic dysfunction in type 2 diabetic patients.

  6. AdaBoost-based algorithm for network intrusion detection.

    Science.gov (United States)

    Hu, Weiming; Hu, Wei; Maybank, Steve

    2008-04-01

    Network intrusion detection aims at distinguishing the attacks on the Internet from normal use of the Internet. It is an indispensable part of the information security system. Due to the variety of network behaviors and the rapid development of attack fashions, it is necessary to develop fast machine-learning-based intrusion detection algorithms with high detection rates and low false-alarm rates. In this correspondence, we propose an intrusion detection algorithm based on the AdaBoost algorithm. In the algorithm, decision stumps are used as weak classifiers. The decision rules are provided for both categorical and continuous features. By combining the weak classifiers for continuous features and the weak classifiers for categorical features into a strong classifier, the relations between these two different types of features are handled naturally, without any forced conversions between continuous and categorical features. Adaptable initial weights and a simple strategy for avoiding overfitting are adopted to improve the performance of the algorithm. Experimental results show that our algorithm has low computational complexity and error rates, as compared with algorithms of higher computational complexity, as tested on the benchmark sample data.

  7. The impact of ambient dose rate measuring network and precipitation radar system for detection of environmental radioactivity released by accident

    International Nuclear Information System (INIS)

    Bleher, M; Stoehlker, U.

    2003-01-01

    For the surveillance of environmental radioactivity, the German measuring network of BfS consists of more than 2000 stations where the ambient gamma dose rate is continuously measured. This network is a helpful tool to detect and localise enhanced environmental contamination from artificial radionuclides. The threshold for early warning is so low, that already an additional dose rate contribution of 0,07 μGy/h is detectable. However, this threshold is frequently exceeded due to precipitation events caused by washout of natural activity in air. Therefore, the precipitation radar system of the German Weather Service provides valuable information on the problem, whether the increase of the ambient dose rate is due to natural or man-made events. In case of an accidental release, the data of this radar system show small area precipitation events and potential local hot spots not detected by the measuring network. For the phase of cloud passage, the ambient dose rate measuring network provides a reliable database for the evaluation of the current situation and its further development. It is possible to compare measured data for dose rate with derived intervention levels for countermeasures like ''sheltering''. Thus, critical regions can be identified and it is possible to verify implemented countermeasures. During and after this phase of cloud passage the measured data of the monitoring network help to adapt the results of the national decision support systems PARK and RODOS. Therefore, it is necessary to derive the actual additional contribution to the ambient dose rate. Map representations of measured dose rate are rapidly available and helpful to optimise measurement strategies of mobile systems and collection strategies for samples of agricultural products. (orig.)

  8. Monitoring nocturnal heart rate with bed sensor.

    Science.gov (United States)

    Migliorini, M; Kortelainen, J M; Pärkkä, J; Tenhunen, M; Himanen, S L; Bianchi, A M

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.

  9. Thoron exhalation rate monitor with absorber

    International Nuclear Information System (INIS)

    Xiao Detao; Zhao Guizhi

    2003-01-01

    A measurement method of thoron exhalation rate is developed based on the characteristic of thorium C' which emits a α particle with higher energy than those of α particles released from radon and radon progenies. The principles of discriminating radon and realizing thoron exhalation rate measurement on the material surface with absorber, the passive and integrated thoron exhalation rate monitor studied, and its calibration coefficient determination method are introduced. The effectiveness of mitigating thoron exhalation rate of wall surface by depressurization inside wall and thoron exhalation rates on some materials surfaces were measured by using the studied monitors. The calibration coefficient of the studied monitor is R=0.246 cm -2 ·(kBq·m -3 ·h) -1 . The lower limit of detection is LLD=18.4 mBq·m -2 ·s -1 when the sampling period is 7 days and the standard deviation of background track densities of the adopted CR-39 SSNTD is s T =1.6 cm -2

  10. Cardiac monitoring for detection of atrial fibrillation after TIA: A systematic review and meta-analysis.

    Science.gov (United States)

    Korompoki, Eleni; Del Giudice, Angela; Hillmann, Steffi; Malzahn, Uwe; Gladstone, David J; Heuschmann, Peter; Veltkamp, Roland

    2017-01-01

    Background and purpose The detection rate of atrial fibrillation has not been studied specifically in transient ischemic attack (TIA) patients although extrapolation from ischemic stroke may be inadequate. We conducted a systematic review and meta-analysis to determine the rate of newly diagnosed atrial fibrillation using different methods of ECG monitoring in TIA. Methods A comprehensive literature search was performed following a pre-specified protocol the PRISMA statement. Prospective observational studies and randomized controlled trials were considered that included TIA patients who underwent cardiac monitoring for >12 h. Primary outcome was frequency of detection of atrial fibrillation ≥30 s. Analyses of subgroups and of duration and type of monitoring were performed. Results Seventeen studies enrolling 1163 patients were included. The pooled atrial fibrillation detection rate for all methods was 4% (95% CI: 2-7%). Yield of monitoring was higher in selected (higher age, more extensive testing for arrhythmias before enrolment, or presumed cardioembolic/cryptogenic cause) than in unselected cohorts (7% vs 3%). Pooled mean atrial fibrillation detection rates rose with duration of monitoring: 4% (24 h), 5% (24 h to 7 days) and 6% (>7 days), respectively. Yield of non-invasive was significantly lower than that of invasive monitoring (4% vs. 11%). Significant heterogeneity was observed among studies (I 2 =60.61%). Conclusion This first meta-analysis of atrial fibrillation detection in TIA patients finds a lower atrial fibrillation detection rate in TIA than reported for IS and TIA cohorts in previous meta-analyses. Prospective studies are needed to determine actual prevalence of atrial fibrillation and optimal diagnostic procedure for atrial fibrillation detection in TIA.

  11. Fiber optic sensor based on reflectivity configurations to detect heart rate

    Science.gov (United States)

    Yunianto, M.; Marzuki, A.; Riyatun, R.; Lestari, D.

    2016-11-01

    Research of optical fiber-based heart rate detection sensor has been conducted using the reflection configurationon the thorax motion modified. Optical fiber used in this research was Plastic Optical Fiber (POF) with a diameter of 0.5. Optical fiber system is made with two pieces of fiber, the first fiber is to serve as a transmitter transmitting light from the source to the reflector membrane, the second fiber serves as a receiver. One of the endsfrom the two fibersis pressed and positioned perpendicular of reflector membrane which is placed on the surface of the chest. The sensor works on the principle of intensity changes captured by the receiver fiber when the reflector membrane gets the vibe from the heart. The light source used is in the form of Light Emitting Diode (LED) and Light Dependent Resistor (LDR) as a light sensor. Variations are performed on the reflector membrane diameter. The light intensity received by the detector increases along with the increasing width of the reflector membrane diameter. The results show that this sensor can detect the harmonic peak at a frequency of 1.5 Hz; 7.5 Hz; 10.5 Hz; and 22.5 Hz in a healthy human heart with an average value of Beat Per Minute (BPM) by 78 times, a prototype sensor that is made can work and function properly.

  12. Molecular evolution of enterovirus 68 detected in the Philippines.

    Directory of Open Access Journals (Sweden)

    Tadatsugu Imamura

    Full Text Available BACKGROUND: Detection of Enterovirus 68 (EV68 has recently been increased. However, underlying evolutionary mechanism of this increasing trend is not fully understood. METHODS: Nasopharyngeal swabs were collected from 5,240 patients with acute respiratory infections in the Philippines from June 2009 to December 2011. EV68 was detected by polymerase chain reaction (PCR targeting for 5' untranslated region (5'UTR, viral protein 1 (VP1, and VP4/VP2. Phylogenetic trees were generated using the obtained sequences. RESULTS: Of the 5,240 tested samples, 12 EV68 positive cases were detected between August and December in 2011 (detection rate, 0.23%. The detection rate was higher among inpatients than outpatients (p<0.0001. Among VP1 sequences detected from 7 patients in 2011, 5 in lineage 2 were diverged from those detected in the Philippines in 2008, however, 2 in lineage 3 were not diverged from strains detected in the Philippines in 2008 but closely associated with strains detected in the United States. Combined with our previous report, EV68 occurrences were observed twice in the Philippines within the last four years. CONCLUSIONS: EV68 detections might be occurring in cyclic patterns, and viruses might have been maintained in the community while some strains might have been newly introduced.

  13. Obese Japanese adults with type 2 diabetes have higher basal metabolic rates than non-diabetic adults.

    Science.gov (United States)

    Miyake, Rieko; Ohkawara, Kazunori; Ishikawa-Takata, Kazuko; Morita, Akemi; Watanabe, Shaw; Tanaka, Shigeho

    2011-01-01

    Several cross-sectional studies in Pima Indians and Caucasians have indicated that obese individuals with type 2 diabetes have a higher basal metabolic rate (BMR) than healthy, obese individuals. However, no study has investigated this comparison in Japanese subjects, who are known to be susceptible to type 2 diabetes due to genetic characteristics. Thirty obese Japanese adults with pre-type 2 diabetes (n=7) or type 2 diabetes (n=13) or without diabetes (n=10) participated in this study. BMR was measured using indirect calorimetry. The relationships between residual BMR (calculated as measured BMR minus BMR adjusted for fat-free mass, fat mass, age, and sex) and biomarkers including fasting glucose, glycosylated hemoglobin (HbA(1c)), fasting insulin, homeostasis model assessment of insulin resistance (HOMA-R), triglycerides, and free fatty acids were examined using Pearson's correlation. BMR in diabetic subjects adjusted for fat-free mass, fat mass, age, and sex was 7.1% higher than in non-diabetic subjects. BMR in diabetic subjects was also significantly (pBMR and fasting glucose (r=0.391, p=0.032). These results indicate that in the Japanese population, obese subjects with type 2 diabetes have higher BMR compared with obese non-diabetic subjects. The fasting glucose level may contribute to these differences.

  14. Understanding the Effect of Response Rate and Class Size Interaction on Students Evaluation of Teaching in a Higher Education

    Science.gov (United States)

    Al Kuwaiti, Ahmed; AlQuraan, Mahmoud; Subbarayalu, Arun Vijay

    2016-01-01

    Objective: This study aims to investigate the interaction between response rate and class size and its effects on students' evaluation of instructors and the courses offered at a higher education Institution in Saudi Arabia. Study Design: A retrospective study design was chosen. Methods: One thousand four hundred and forty four different courses…

  15. Modified Mitchell osteotomy alone does not have higher rate of residual metatarsalgia than combined first and lesser metatarsal osteotomy

    Directory of Open Access Journals (Sweden)

    Shu-Jung Chen

    2015-04-01

    Full Text Available Transfer metatarsalgia (TM is a common forefoot disorder secondary to hallux valgus (HV. Some authors suggest that a combined lesser metatarsal osteotomy while undergoing HV surgery improves metatarsalgia, whereas others concluded that isolated HV corrective osteotomy can improve symptomatic metatarsalgia. The main purpose of this retrospective study was to compare clinical outcomes in patients with and without combined lesser metatarsal osteotomy while receiving HV correction surgery. We retrospectively reviewed the patients who underwent osteotomy for HV correction between January 2000 and December 2010. All patients underwent HV correction with modified Mitchell osteotomy. Clinical evaluations including the American Orthopaedic Foot and Ankle Society score and residual metatarsalgia were assessed, and radiographic measurements were carried out. Sixty-five patients (83 feet meeting the selection criteria were enrolled. Thirty feet receiving a combined lesser metatarsal osteotomy were classified as the combined surgery (CS group, and the others were classified as the control (CN group (53 feet. The overall rate of persistent symptomatic metatarsalgia was 19.28% after operative treatment. There were six feet with residual metatarsalgia in the CS group, and 10 feet in the CN group. There was no significant difference in the rate of persistent symptoms between the two groups (p = 0.9. According to this result, modified Mitchell osteotomy alone did not have a higher rate of residual metatarsalgia than CS. We also found that the average recovery rate of TM was about 80.7% and those patients whose preoperative HV angle was > 30° had the higher risk of residual metatarsalgia after surgery.

  16. Detection Rate and Clinical Impact of Respiratory Viruses in Children with Kawasaki Disease

    Directory of Open Access Journals (Sweden)

    Ja Hye Kim

    2012-12-01

    Full Text Available &lt;B&gt;Purpose:&lt;/B&gt; The purpose of this prospective case-control study was to survey the detection rate of respiratory viruses in children with Kawasaki disease (KD by using multiplex reverse transcriptasepolymerase chain reaction (RT-PCR, and to investigate the clinical implications of the prevalence of respiratory viruses during the acute phase of KD. &lt;B&gt;Methods:&lt;/B&gt; RT-PCR assays were carried out to screen for the presence of respiratory syncytial virus A and B, adenovirus, rhinovirus, parainfluenza viruses 1 to 4, influenza virus A and B, metapneumovirus, bocavirus, coronavirus OC43/229E and NL63, and enterovirus in nasopharyngeal secretions of 55 KD patients and 78 control subjects. &lt;B&gt;Results:&lt;/B&gt; Virus detection rates in KD patients and control subjects were 32.7% and 30.8%, respectively (P=0.811. However, there was no significant association between the presence of any of the 15 viruses and the incidence of KD. Comparisons between the 18 patients with positive RT-PCR results and the other 37 KD patients revealed no significant differences in terms of clinical findings (including the prevalence of incomplete presentation of the disease and coronary artery diameter. &lt;B&gt;Conclusion:&lt;/B&gt; A positive RT-PCR for currently epidemic respiratory viruses should not be used as an evidence against the diagnosis of KD. These viruses were not associated with the incomplete presentation of KD and coronary artery dilatation.

  17. Individual differences in rate of encoding predict estimates of visual short-term memory capacity (K).

    Science.gov (United States)

    Jannati, Ali; McDonald, John J; Di Lollo, Vincent

    2015-06-01

    The capacity of visual short-term memory (VSTM) is commonly estimated by K scores obtained with a change-detection task. Contrary to common belief, K may be influenced not only by capacity but also by the rate at which stimuli are encoded into VSTM. Experiment 1 showed that, contrary to earlier conclusions, estimates of VSTM capacity obtained with a change-detection task are constrained by temporal limitations. In Experiment 2, we used change-detection and backward-masking tasks to obtain separate within-subject estimates of K and of rate of encoding, respectively. A median split based on rate of encoding revealed significantly higher K estimates for fast encoders. Moreover, a significant correlation was found between K and the estimated rate of encoding. The present findings raise the prospect that the reported relationships between K and such cognitive concepts as fluid intelligence may be mediated not only by VSTM capacity but also by rate of encoding. (c) 2015 APA, all rights reserved).

  18. Endometrial Scratch Injury Induces Higher Pregnancy Rate for Women With Unexplained Infertility Undergoing IUI With Ovarian Stimulation: A Randomized Controlled Trial.

    Science.gov (United States)

    Maged, Ahmed M; Al-Inany, Hesham; Salama, Khaled M; Souidan, Ibrahim I; Abo Ragab, Hesham M; Elnassery, Noura

    2016-02-01

    To explore the impact of endometrial scratch injury (ESI) on intrauterine insemination (IUI) success. One hundred and fifty four infertile women received 100 mg of oral clomiphene citrate for 5 days starting on day 3 of the menstrual cycle. Patients were randomized to 2 equal groups: Group C received IUI without ESI and group S had ESI. Successful pregnancy was confirmed by ultrasound. 13, 21, and 10 women got pregnant after the first, second, and third IUI trials, respectively, with 28.6% cumulative pregnancy rate (PR). The cumulative PR was significantly higher in group S (39%) compared to group C (18.2%). The PR in group S was significantly higher compared to that in group C at the second and third trials. The PR was significantly higher in group S at the second trial compared to that reported in the same group at the first trial but nonsignificantly higher compared to that reported during the third trial, while in group C, the difference was nonsignificant. Eight pregnant women had first trimester abortion with 18.2% total abortion rate with nonsignificant difference between studied groups. The ESI significantly improves the outcome of IUI in women with unexplained infertility especially when conducted 1 month prior to IUI. © The Author(s) 2015.

  19. Comparison of Detection Rate and Mutational Pattern of Drug-Resistant Mutations Between a Large Cohort of Genotype B and Genotype C Hepatitis B Virus-Infected Patients in North China.

    Science.gov (United States)

    Li, Xiaodong; Liu, Yan; Xin, Shaojie; Ji, Dong; You, Shaoli; Hu, Jinhua; Zhao, Jun; Wu, Jingjing; Liao, Hao; Zhang, Xin-Xin; Xu, Dongping

    2017-06-01

    The study aimed to investigate the association of prevalent genotypes in China (HBV/C and HBV/B) with HBV drug-resistant mutations. A total of 13,847 nucleos(t)ide analogue (NA)-treated patients with chronic HBV infection from North China were enrolled. HBV genotypes and resistant mutations were determined by direct sequencing and confirmed by clonal sequencing if necessary. HBV/B, HBV/C, and HBV/D occupied 14.3%, 84.9%, and 0.8% across the study population, respectively. NA usage had no significant difference between HBV/B- and HBV/C-infected patients. Lamivudine-resistant mutations were more frequently detected in HBV/C-infected patients, compared with HBV/B-infected patients (31.67% vs. 25.26%, p M250 V/I/L substitution (0.67% vs. 1.46%, p < 0.01). Multidrug-resistant mutations (defined as coexistence of mutation to nucleoside and nucleotide analogues) were detected in 104 patients. HBV/C-infected patients had a higher detection rate of multidrug-resistant mutation than HBV/B-infected patients (0.83% vs. 0.35%, p < 0.05). The study for the first time clarified that HBV/C-infected patients had a higher risk to develop multidrug-resistant mutations, compared with HBV/B-infected patients; and HBV/C- and HBV/B-infected patients had different inclinations in the ETV-resistant mutational pattern.

  20. APPRAISAL OF STUDENT RATING AS A MEASURE TO MANAGE THE QUALITY OF HIGHER EDUCATION IN INDIA: AN INSTITUTIONAL STUDY USING SIX SIGMA MODEL APPROACH

    Directory of Open Access Journals (Sweden)

    Arun Vijay

    2013-12-01

    Full Text Available Students' rating of teaching is one of the most widely accepted methods of measuring the quality in Higher Education worldwide. The overall experience gained by the students during their academic journey in their respective college is a key factor to determine the Institutional Quality. This study was conducted among the Physical Therapy students with an objective to capture the overall experience related to various aspects of their Academic environment including teaching and learning process adopted in their college. To facilitate that, a unique questionnaire called,"Academic Environment Evaluation Questionnaire (AEEQ was developed covering all the important teaching elements of the Higher Education Institutions. The students' opinion was captured and analyzed through six sigma analytical tool using Poisson distribution model. From the non-conformance level captured through the responses from the students about the various categories of teaching and learning elements, the corresponding Sigma rating for each teaching element was measured. Accordingly, a six point Quality rating system was developed customizing to each sigma values. This study brings a new, innovative student driven Quality rating system for the Higher Education Institutions in India.

  1. Impact of a shift in nuchal translucency measurements on the detection rate of first-trimester Down syndrome screening: A population-based study.

    Science.gov (United States)

    Fries, Nicolas; Salomon, Laurent J; Muller, Françoise; Dreux, Sophie; Houfflin-Debarge, Véronique; Coquel, Philippe; Kleinfinger, Pascale; Dommergues, Marc

    2018-01-01

    To assess the distribution of nuchal translucency (NT) measurements following a national policy without credentialing and its impact on first-trimester Down syndrome screening (DSS) detection rate. All first-trimester DSS data recorded in France (2010-2014) were collected by the laboratories in charge via an Internet database (https://www.bionuqual.org/echo.php). There was no minimal requirement for image quality to allow sonographers to enter the screening process. A subgroup of DSS with complete DS follow-up corresponded to 1614 sonographers. Based on the distribution of maternal age, DS detection rate was calculated and split as a function of the distribution of NT multiple of the median (MoM). Four thousand nine hundred forty-three sonographers performed 2,337,372 NT measurements. Median NT expressed in MoM was 0.83. Screenings with complete follow-up consisted of 197,417 screenings, in which DSS detection rates were respectively 70.4%, 70.9%, 79.4%, 87.7%, and 79.5% for the following median NT MoM ranges: 0.99 (trend χ = 12.21; P = .0158). In France, following a policy of quality assessment without standardized credentialing, the distribution of NT measurements did not fit the expected distribution. Down syndrome detection rate was 10% lower in screenings by sonographers with a median NT < 0.80 MoM. © 2017 John Wiley & Sons, Ltd.

  2. Incorporating an Exercise Detection, Grading, and Hormone Dosing Algorithm Into the Artificial Pancreas Using Accelerometry and Heart Rate

    OpenAIRE

    Jacobs, Peter G.; Resalat, Navid; El Youssef, Joseph; Reddy, Ravi; Branigan, Deborah; Preiser, Nicholas; Condon, John; Castle, Jessica

    2015-01-01

    In this article, we present several important contributions necessary for enabling an artificial endocrine pancreas (AP) system to better respond to exercise events. First, we show how exercise can be automatically detected using body-worn accelerometer and heart rate sensors. During a 22 hour overnight inpatient study, 13 subjects with type 1 diabetes wearing a Zephyr accelerometer and heart rate monitor underwent 45 minutes of mild aerobic treadmill exercise while controlling their glucose ...

  3. Predicting higher education graduation rates from institutional characteristics and resource allocation

    Directory of Open Access Journals (Sweden)

    Florence A. Hamrick

    2004-05-01

    Full Text Available This study incorporated institutional characteristics (e.g., Carnegie type, selectivity and resource allocations (e.g., instructional expenditures, student affairs expenditures into a statistical model to predict undergraduate graduation rates. Instructional expenditures, library expenditures, and a number of institutional classification variables were significant predictors of graduation rates. Based on these results, recommendations as well as warranted cautions are included about allocating academic financial resources to optimize graduation rates

  4. A Suspicious Action Detection System Considering Time Series

    Science.gov (United States)

    Kozuka, Noriaki; Kimura, Koji; Hagiwara, Masafumi

    The paper proposes a new system that can detect suspicious actions such as a car break-in and surroundings in an open space parking, based on image processing. The proposed system focuses on three points of “order”, “time”, and “location” of human actions. The proposed system has the following features: it 1) deals time series data flow, 2) estimates human actions and the location, 3) extracts suspicious action detection rules automatically, 4) detects suspicious actions using the suspicious score. We carried out experiments using real image sequences. As a result, we obtained about 7.8% higher estimation rate than the conventional system.

  5. Higher Education Support Services and Graduation Rates of Structured Education Program Students

    Science.gov (United States)

    Hepner, Seth

    2017-01-01

    The 1st-year retention rate of the Structured Education Program (SEP) is 90%, yet the 6-year graduation rate of SEP students is 29%. The gap between SEP 1st-year retention and graduation rates is the problem that this study addressed. The low graduation rate of SEP students is an important issue because graduation rates are used to measure the…

  6. Effect of temperature during ion sputtering on the surface segregation rate of antimony in an iron-antimony alloy at higher temperatures

    International Nuclear Information System (INIS)

    Oku, M.; Hirokawa, K.; Kimura, H.; Suzuki, S.

    1986-01-01

    The surface segregation of antimony in an iron-0.23 at% antimony alloy was studied by XPS. The segregation rate in the temperature range between 800 and 900 K depends on the temperature during sputtering with argon ion of kinetic energy of 1 keV. The sputtering at room temperature or 473 K gives higher values of the segregation rate than those at 673 K. Both cases give the activation energy of 170 kJmol -1 for the surface segregation rate. The segregation of antimony is not observed after the sample is heated at 1000 K. (author)

  7. Automated detection of retinal disease.

    Science.gov (United States)

    Helmchen, Lorens A; Lehmann, Harold P; Abràmoff, Michael D

    2014-11-01

    Nearly 4 in 10 Americans with diabetes currently fail to undergo recommended annual retinal exams, resulting in tens of thousands of cases of blindness that could have been prevented. Advances in automated retinal disease detection could greatly reduce the burden of labor-intensive dilated retinal examinations by ophthalmologists and optometrists and deliver diagnostic services at lower cost. As the current availability of ophthalmologists and optometrists is inadequate to screen all patients at risk every year, automated screening systems deployed in primary care settings and even in patients' homes could fill the current gap in supply. Expanding screens to all patients at risk by switching to automated detection systems would in turn yield significantly higher rates of detecting and treating diabetic retinopathy per dilated retinal examination. Fewer diabetic patients would develop complications such as blindness, while ophthalmologists could focus on more complex cases.

  8. The Contact State Monitoring for Seal End Faces Based on Acoustic Emission Detection

    Directory of Open Access Journals (Sweden)

    Xiaohui Li

    2016-01-01

    Full Text Available Monitoring the contact state of seal end faces would help the early warning of the seal failure. In the acoustic emission (AE detection for mechanical seal, the main difficulty is to reduce the background noise and to classify the dispersed features. To solve these problems and achieve higher detection rates, a new approach based on genetic particle filter with autoregression (AR-GPF and hypersphere support vector machine (HSSVM is presented. First, AR model is used to build the dynamic state space (DSS of the AE signal, and GPF is used for signal filtering. Then, multiple features are extracted, and a classification model based on HSSVM is constructed for state recognition. In this approach, AR-GPF is an excellent time-domain method for noise reduction, and HSSVM has advantage on those dispersed features. Finally experimental data shows that the proposed method can effectively detect the contact state of the seal end faces and has higher accuracy rates than some other existing methods.

  9. Non-Invasive Detection of Respiration and Heart Rate with a Vehicle Seat Sensor.

    Science.gov (United States)

    Wusk, Grace; Gabler, Hampton

    2018-05-08

    This study demonstrates the feasibility of using a seat sensor designed for occupant classification from a production passenger vehicle to measure an occupant’s respiration rate (RR) and heart rate (HR) in a laboratory setting. Relaying occupant vital signs after a crash could improve emergency response by adding a direct measure of the occupant state to an Advanced Automatic Collision Notification (AACN) system. Data was collected from eleven participants with body weights ranging from 42 to 91 kg using a Ford Mustang passenger seat and seat sensor. Using a ballistocardiography (BCG) approach, the data was processed by time domain filtering and frequency domain analysis using the fast Fourier transform to yield RR and HR in a 1-min sliding window. Resting rates over the 30-min data collection and continuous RR and HR signals were compared to laboratory physiological instruments using the Bland-Altman approach. Differences between the seat sensor and reference sensor were within 5 breaths per minute for resting RR and within 15 beats per minute for resting HR. The time series comparisons for RR and HR were promising with the frequency analysis technique outperforming the peak detection technique. However, future work is necessary for more accurate and reliable real-time monitoring of RR and HR outside the laboratory setting.

  10. Does Prison Crowding Predict Higher Rates of Substance Use Related Parole Violations? A Recurrent Events Multi-Level Survival Analysis.

    Science.gov (United States)

    Ruderman, Michael A; Wilson, Deirdra F; Reid, Savanna

    2015-01-01

    This administrative data-linkage cohort study examines the association between prison crowding and the rate of post-release parole violations in a random sample of prisoners released with parole conditions in California, for an observation period of two years (January 2003 through December 2004). Crowding overextends prison resources needed to adequately protect inmates and provide drug rehabilitation services. Violence and lack of access to treatment are known risk factors for drug use and substance use disorders. These and other psychosocial effects of crowding may lead to higher rates of recidivism in California parolees. Rates of parole violation for parolees exposed to high and medium levels of prison crowding were compared to parolees with low prison crowding exposure. Hazard ratios (HRs) with 95% confidence intervals (CIs) were estimated using a Cox model for recurrent events. Our dataset included 13070 parolees in California, combining individual level parolee data with aggregate level crowding data for multilevel analysis. Comparing parolees exposed to high crowding with those exposed to low crowding, the effect sizes from greatest to least were absconding violations (HR 3.56 95% CI: 3.05-4.17), drug violations (HR 2.44 95% CI: 2.00-2.98), non-violent violations (HR 2.14 95% CI: 1.73-2.64), violent and serious violations (HR 1.88 95% CI: 1.45-2.43), and technical violations (HR 1.86 95% CI: 1.37-2.53). Prison crowding predicted higher rates of parole violations after release from prison. The effect was magnitude-dependent and particularly strong for drug charges. Further research into whether adverse prison experiences, such as crowding, are associated with recidivism and drug use in particular may be warranted.

  11. A study of pipe flow rate measurement using air-coupled ultrasound

    International Nuclear Information System (INIS)

    Tsukada, Keisuke; Tsuzuki, Nobuyoshi; Kikura, Hiroshige

    2013-01-01

    A non-contact flow meter employing air-coupled ultrasound is developed in this research. Ultrasonic flow meter is applied to the higher accuracy flow rate measurement, compared with pressure difference flow meter. However, ultrasonic flow meter has difficulty to measure in severe conditions such as in the condition of high temperature, high pressure condition, and radioactive materials in fluid. Especially, in high temperature condition, piezoelectric device in ultrasonic sensors lose the piezoelectricity, and it becomes difficult to transmit or detect ultrasound. Thus, in this research, ultrasonic sensors are fixed in the air. Ultrasonic sensors transmit and detect ultrasound through air, and measure the flow rate in the pipe. However, most of ultrasound is refracted and reflected at the boundaries between air and the pipe. And detected signals are weak. To increase the signal level, we developed focusing ultrasonic sensors that was optimized for the pipe flow measurement. And employing these focusing sensors the flow rate measurement has been done in order to evaluate the air-coupled ultrasonic flow meter by the ultrasonic beam focusing technique. (author)

  12. Photon Counting Using Edge-Detection Algorithm

    Science.gov (United States)

    Gin, Jonathan W.; Nguyen, Danh H.; Farr, William H.

    2010-01-01

    -bit comparator, which digitizes the input referenced to an adjustable threshold value. This results in four independent serial sample streams of binary 1s and 0s, which are ORed together at rates up to 10 GHz. This single serial stream is then deserialized by a factor of 16 to create 16 signal lines at a rate of 622.5 MHz or lower for input to a high-speed digital processor assembly. The new design and corresponding hardware can be employed with a quad-photon counting detector capable of handling photon rates on the order of multi-gigaphotons per second, whereas prior art was only capable of handling a single input at 1/4 the flux rate. Additionally, the hardware edge-detection algorithm has provided the ability to process 3-10 higher photon flux rates than previously possible by removing the limitation that photoncounting detector output pulses on multiple channels being ORed not overlap. Now, only the leading edges of the pulses are required to not overlap. This new photon counting digitizer hardware architecture supports a universal front end for an optical communications receiver operating at data rates from kilobits to over one gigabit per second to meet increased mission data volume requirements.

  13. A Method for Harmonic Sources Detection based on Harmonic Distortion Power Rate

    Science.gov (United States)

    Lin, Ruixing; Xu, Lin; Zheng, Xian

    2018-03-01

    Harmonic sources detection at the point of common coupling is an essential step for harmonic contribution determination and harmonic mitigation. The harmonic distortion power rate index is proposed for harmonic source location based on IEEE Std 1459-2010 in the paper. The method only based on harmonic distortion power is not suitable when the background harmonic is large. To solve this problem, a threshold is determined by the prior information, when the harmonic distortion power is larger than the threshold, the customer side is considered as the main harmonic source, otherwise, the utility side is. A simple model of public power system was built in MATLAB/Simulink and field test results of typical harmonic loads verified the effectiveness of proposed method.

  14. A strong response to selection on mass-independent maximal metabolic rate without a correlated response in basal metabolic rate.

    Science.gov (United States)

    Wone, B W M; Madsen, P; Donovan, E R; Labocha, M K; Sears, M W; Downs, C J; Sorensen, D A; Hayes, J P

    2015-04-01

    Metabolic rates are correlated with many aspects of ecology, but how selection on different aspects of metabolic rates affects their mutual evolution is poorly understood. Using laboratory mice, we artificially selected for high maximal mass-independent metabolic rate (MMR) without direct selection on mass-independent basal metabolic rate (BMR). Then we tested for responses to selection in MMR and correlated responses to selection in BMR. In other lines, we antagonistically selected for mice with a combination of high mass-independent MMR and low mass-independent BMR. All selection protocols and data analyses included body mass as a covariate, so effects of selection on the metabolic rates are mass adjusted (that is, independent of effects of body mass). The selection lasted eight generations. Compared with controls, MMR was significantly higher (11.2%) in lines selected for increased MMR, and BMR was slightly, but not significantly, higher (2.5%). Compared with controls, MMR was significantly higher (5.3%) in antagonistically selected lines, and BMR was slightly, but not significantly, lower (4.2%). Analysis of breeding values revealed no positive genetic trend for elevated BMR in high-MMR lines. A weak positive genetic correlation was detected between MMR and BMR. That weak positive genetic correlation supports the aerobic capacity model for the evolution of endothermy in the sense that it fails to falsify a key model assumption. Overall, the results suggest that at least in these mice there is significant capacity for independent evolution of metabolic traits. Whether that is true in the ancestral animals that evolved endothermy remains an important but unanswered question.

  15. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates

    Energy Technology Data Exchange (ETDEWEB)

    Bluekens, Adriana M.J. [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); St. Elisabeth Hospital, Department of Radiology, Tilburg (Netherlands); Karssemeijer, Nico [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Beijerinck, David; Deurenberg, Jan J.M. [Preventicon Screening Centre/Mid-West, Utrecht (Netherlands); Engen, Ruben E. van [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Broeders, Mireille J.M. [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Radboud University Nijmegen Medical Centre, Department of Epidemiology, Biostatistics and HTA, Nijmegen (Netherlands); Heeten, Gerard J. den [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Academic Medical Centre (AMC), Department of Radiology, Amsterdam (Netherlands)

    2010-09-15

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p <.001), with a significant increase in cancer detection (p =.010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection. (orig.)

  16. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates.

    Science.gov (United States)

    Bluekens, Adriana M J; Karssemeijer, Nico; Beijerinck, David; Deurenberg, Jan J M; van Engen, Ruben E; Broeders, Mireille J M; den Heeten, Gerard J

    2010-09-01

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p < .001), with a significant increase in cancer detection (p = .010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection.

  17. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates

    International Nuclear Information System (INIS)

    Bluekens, Adriana M.J.; Karssemeijer, Nico; Beijerinck, David; Deurenberg, Jan J.M.; Engen, Ruben E. van; Broeders, Mireille J.M.; Heeten, Gerard J. den

    2010-01-01

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p <.001), with a significant increase in cancer detection (p =.010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection. (orig.)

  18. Development of materials for higher burn-up rates

    International Nuclear Information System (INIS)

    Ehrlich, K.; Anderko, K.

    1983-01-01

    The results obtained so far concerning both high-nickel austenitic steels (X10CrNiMoTiB10 25) and ferritic-martensitic steels (X18CrMoVNb12 1 corresponds to 1.4914) justify the expectations placed in these materials. Future R and D work will concentrate on high-nickel austenitic steels, in particular on in-pile residence time in the range of maximum cladding mean temperatures (He embrittlement), on confirmation of the fairly good swelling and creep behaviour to be obtained from neutron irradiation experiments as well as on material qualification and technology. As far the development in the field of martensitic steels the major question concerns the influence of neutron irradiation on the transient temperature. It is just as important and interesting to detect and describe the ruling in-pile creep mechanism in the 400 to 600 0 C range. Furthermore, questions on the fabrication and qualification of cladding tube boxes are also preeminent. (orig.) [de

  19. A Combined Syntactical and Statistical Approach for R Peak Detection in Real-Time Long-Term Heart Rate Variability Analysis

    Directory of Open Access Journals (Sweden)

    David Pang

    2018-06-01

    Full Text Available Long-term heart rate variability (HRV analysis is useful as a noninvasive technique for autonomic nervous system activity assessment. It provides a method for assessing many physiological and pathological factors that modulate the normal heartbeat. The performance of HRV analysis systems heavily depends on a reliable and accurate detection of the R peak of the QRS complex. Ectopic beats caused by misdetection or arrhythmic events can introduce bias into HRV results, resulting in significant problems in their interpretation. This study presents a novel method for long-term detection of normal R peaks (which represent the normal heartbeat in electrocardiographic signals, intended specifically for HRV analysis. The very low computational complexity of the proposed method, which combines and exploits the advantages of syntactical and statistical approaches, enables real-time applications. The approach was validated using the Massachusetts Institute of Technology–Beth Israel Hospital Normal Sinus Rhythm and the Fantasia database, and has a sensitivity, positive predictivity, detection error rate, and accuracy of 99.998, 99.999, 0.003, and 99.996%, respectively.

  20. Faster eating rates are associated with higher energy intakes during an ad libitum meal, higher BMI and greater adiposity among 4·5-year-old children: results from the Growing Up in Singapore Towards Healthy Outcomes (GUSTO) cohort.

    Science.gov (United States)

    Fogel, Anna; Goh, Ai Ting; Fries, Lisa R; Sadananthan, Suresh A; Velan, S Sendhil; Michael, Navin; Tint, Mya-Thway; Fortier, Marielle V; Chan, Mei Jun; Toh, Jia Ying; Chong, Yap-Seng; Tan, Kok Hian; Yap, Fabian; Shek, Lynette P; Meaney, Michael J; Broekman, Birit F P; Lee, Yung Seng; Godfrey, Keith M; Chong, Mary F F; Forde, Ciarán G

    2017-04-01

    Faster eating rates are associated with increased energy intake, but little is known about the relationship between children's eating rate, food intake and adiposity. We examined whether children who eat faster consume more energy and whether this is associated with higher weight status and adiposity. We hypothesised that eating rate mediates the relationship between child weight and ad libitum energy intake. Children (n 386) from the Growing Up in Singapore Towards Healthy Outcomes cohort participated in a video-recorded ad libitum lunch at 4·5 years to measure acute energy intake. Videos were coded for three eating-behaviours (bites, chews and swallows) to derive a measure of eating rate (g/min). BMI and anthropometric indices of adiposity were measured. A subset of children underwent MRI scanning (n 153) to measure abdominal subcutaneous and visceral adiposity. Children above/below the median eating rate were categorised as slower and faster eaters, and compared across body composition measures. There was a strong positive relationship between eating rate and energy intake (r 0·61, P<0·001) and a positive linear relationship between eating rate and children's BMI status. Faster eaters consumed 75 % more energy content than slower eating children (Δ548 kJ (Δ131 kcal); 95 % CI 107·6, 154·4, P<0·001), and had higher whole-body (P<0·05) and subcutaneous abdominal adiposity (Δ118·3 cc; 95 % CI 24·0, 212·7, P=0·014). Mediation analysis showed that eating rate mediates the link between child weight and energy intake during a meal (b 13·59; 95 % CI 7·48, 21·83). Children who ate faster had higher energy intake, and this was associated with increased BMI z-score and adiposity.

  1. Comparing the effects of age on amplitude modulation and frequency modulation detection.

    Science.gov (United States)

    Wallaert, Nicolas; Moore, Brian C J; Lorenzi, Christian

    2016-06-01

    Frequency modulation (FM) and amplitude modulation (AM) detection thresholds were measured at 40 dB sensation level for young (22-28 yrs) and older (44-66 yrs) listeners with normal audiograms for a carrier frequency of 500 Hz and modulation rates of 2 and 20 Hz. The number of modulation cycles, N, varied between 2 and 9. For FM detection, uninformative AM at the same rate as the FM was superimposed to disrupt excitation-pattern cues. For both groups, AM and FM detection thresholds were lower for the 2-Hz than for the 20-Hz rate, and AM and FM detection thresholds decreased with increasing N. Thresholds were higher for older than for younger listeners, especially for FM detection at 2 Hz, possibly reflecting the effect of age on the use of temporal-fine-structure cues for 2-Hz FM detection. The effect of increasing N was similar across groups for both AM and FM. However, at 20 Hz, older listeners showed a greater effect of increasing N than younger listeners for both AM and FM. The results suggest that ageing reduces sensitivity to both excitation-pattern and temporal-fine-structure cues for modulation detection, but more so for the latter, while sparing temporal integration of these cues at low modulation rates.

  2. Use of dew-point detection for quantitative measurement of sweating rate

    Science.gov (United States)

    Brengelmann, G. L.; Mckeag, M.; Rowell, L. B.

    1975-01-01

    A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

  3. Detection rates of geckos in visual surveys: Turning confounding variables into useful knowledge

    Science.gov (United States)

    Lardner, Bjorn; Rodda, Gordon H.; Yackel Adams, Amy A.; Savidge, Julie A.; Reed, Robert N.

    2016-01-01

    Transect surveys without some means of estimating detection probabilities generate population size indices prone to bias because survey conditions differ in time and space. Knowing what causes such bias can help guide the collection of relevant survey covariates, correct the survey data, anticipate situations where bias might be unacceptably large, and elucidate the ecology of target species. We used negative binomial regression to evaluate confounding variables for gecko (primarily Hemidactylus frenatus and Lepidodactylus lugubris) counts on 220-m-long transects surveyed at night, primarily for snakes, on 9,475 occasions. Searchers differed in gecko detection rates by up to a factor of six. The worst and best headlamps differed by a factor of at least two. Strong winds had a negative effect potentially as large as those of searchers or headlamps. More geckos were seen during wet weather conditions, but the effect size was small. Compared with a detection nadir during waxing gibbous (nearly full) moons above the horizon, we saw 28% more geckos during waning crescent moons below the horizon. A sine function suggested that we saw 24% more geckos at the end of the wet season than at the end of the dry season. Fluctuations on a longer timescale also were verified. Disturbingly, corrected data exhibited strong short-term fluctuations that covariates apparently failed to capture. Although some biases can be addressed with measured covariates, others will be difficult to eliminate as a significant source of error in longterm monitoring programs.

  4. Fuzzy Based Advanced Hybrid Intrusion Detection System to Detect Malicious Nodes in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Rupinder Singh

    2017-01-01

    Full Text Available In this paper, an Advanced Hybrid Intrusion Detection System (AHIDS that automatically detects the WSNs attacks is proposed. AHIDS makes use of cluster-based architecture with enhanced LEACH protocol that intends to reduce the level of energy consumption by the sensor nodes. AHIDS uses anomaly detection and misuse detection based on fuzzy rule sets along with the Multilayer Perceptron Neural Network. The Feed Forward Neural Network along with the Backpropagation Neural Network are utilized to integrate the detection results and indicate the different types of attackers (i.e., Sybil attack, wormhole attack, and hello flood attack. For detection of Sybil attack, Advanced Sybil Attack Detection Algorithm is developed while the detection of wormhole attack is done by Wormhole Resistant Hybrid Technique. The detection of hello flood attack is done by using signal strength and distance. An experimental analysis is carried out in a set of nodes; 13.33% of the nodes are determined as misbehaving nodes, which classified attackers along with a detection rate of the true positive rate and false positive rate. Sybil attack is detected at a rate of 99,40%; hello flood attack has a detection rate of 98, 20%; and wormhole attack has a detection rate of 99, 20%.

  5. Low contrast detectability for color patterns variation of display images

    International Nuclear Information System (INIS)

    Ogura, Akio

    1998-01-01

    In recent years, the radionuclide images are acquired in digital form and displayed with false colors for signal intensity. This color scales for signal intensity have various patterns. In this study, low contrast detectability was compared the performance of gray scale cording with three color scales: the hot color scale, prism color scale and stripe color scale. SPECT images of brain phantom were displayed using four color patterns. These printed images and display images were evaluated with ROC analysis. Display images were indicated higher detectability than printed images. The hot scale and gray scale images indicated better Az of ROC than prism scale images because the prism scale images showed higher false positive rate. (author)

  6. Does Prison Crowding Predict Higher Rates of Substance Use Related Parole Violations? A Recurrent Events Multi-Level Survival Analysis.

    Directory of Open Access Journals (Sweden)

    Michael A Ruderman

    Full Text Available This administrative data-linkage cohort study examines the association between prison crowding and the rate of post-release parole violations in a random sample of prisoners released with parole conditions in California, for an observation period of two years (January 2003 through December 2004.Crowding overextends prison resources needed to adequately protect inmates and provide drug rehabilitation services. Violence and lack of access to treatment are known risk factors for drug use and substance use disorders. These and other psychosocial effects of crowding may lead to higher rates of recidivism in California parolees.Rates of parole violation for parolees exposed to high and medium levels of prison crowding were compared to parolees with low prison crowding exposure. Hazard ratios (HRs with 95% confidence intervals (CIs were estimated using a Cox model for recurrent events. Our dataset included 13070 parolees in California, combining individual level parolee data with aggregate level crowding data for multilevel analysis.Comparing parolees exposed to high crowding with those exposed to low crowding, the effect sizes from greatest to least were absconding violations (HR 3.56 95% CI: 3.05-4.17, drug violations (HR 2.44 95% CI: 2.00-2.98, non-violent violations (HR 2.14 95% CI: 1.73-2.64, violent and serious violations (HR 1.88 95% CI: 1.45-2.43, and technical violations (HR 1.86 95% CI: 1.37-2.53.Prison crowding predicted higher rates of parole violations after release from prison. The effect was magnitude-dependent and particularly strong for drug charges. Further research into whether adverse prison experiences, such as crowding, are associated with recidivism and drug use in particular may be warranted.

  7. Does Prison Crowding Predict Higher Rates of Substance Use Related Parole Violations? A Recurrent Events Multi-Level Survival Analysis

    Science.gov (United States)

    Ruderman, Michael A.; Wilson, Deirdra F.; Reid, Savanna

    2015-01-01

    Objective This administrative data-linkage cohort study examines the association between prison crowding and the rate of post-release parole violations in a random sample of prisoners released with parole conditions in California, for an observation period of two years (January 2003 through December 2004). Background Crowding overextends prison resources needed to adequately protect inmates and provide drug rehabilitation services. Violence and lack of access to treatment are known risk factors for drug use and substance use disorders. These and other psychosocial effects of crowding may lead to higher rates of recidivism in California parolees. Methods Rates of parole violation for parolees exposed to high and medium levels of prison crowding were compared to parolees with low prison crowding exposure. Hazard ratios (HRs) with 95% confidence intervals (CIs) were estimated using a Cox model for recurrent events. Our dataset included 13070 parolees in California, combining individual level parolee data with aggregate level crowding data for multilevel analysis. Results Comparing parolees exposed to high crowding with those exposed to low crowding, the effect sizes from greatest to least were absconding violations (HR 3.56 95% CI: 3.05–4.17), drug violations (HR 2.44 95% CI: 2.00–2.98), non-violent violations (HR 2.14 95% CI: 1.73–2.64), violent and serious violations (HR 1.88 95% CI: 1.45–2.43), and technical violations (HR 1.86 95% CI: 1.37–2.53). Conclusions Prison crowding predicted higher rates of parole violations after release from prison. The effect was magnitude-dependent and particularly strong for drug charges. Further research into whether adverse prison experiences, such as crowding, are associated with recidivism and drug use in particular may be warranted. PMID:26492490

  8. Theoretical and computational study of the energy dependence of the muon transfer rate from hydrogen to higher-Z gases

    Energy Technology Data Exchange (ETDEWEB)

    Bakalov, Dimitar, E-mail: dbakalov@inrne.bas.bg [Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, Tsarigradsko chaussée 72, Sofia 1784 (Bulgaria); Adamczak, Andrzej [Institute of Nuclear Physics, Polish Academy of Sciences, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Stoilov, Mihail [Institute for Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, Tsarigradsko chaussée 72, Sofia 1784 (Bulgaria); Vacchi, Andrea [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Via A. Valerio 2, 34127 Trieste (Italy)

    2015-01-23

    The recent PSI Lamb shift experiment and the controversy about proton size revived the interest in measuring the hyperfine splitting in muonic hydrogen as an alternative possibility for comparing ordinary and muonic hydrogen spectroscopy data on proton electromagnetic structure. This measurement critically depends on the energy dependence of the muon transfer rate to heavier gases in the epithermal range. The available data provide only qualitative information, and the theoretical predictions have not been verified. We propose a new method by measurements of the transfer rate in thermalized target at different temperatures, estimate its accuracy and investigate the optimal experimental conditions. - Highlights: • Method for measuring the energy dependence of muon transfer rate to higher-Z gases. • Thermalization and depolarization of muonic hydrogen studied by Monte Carlo method. • Optimal experimental conditions determined by Monte Carlo simulations. • Mathematical model and for estimating the uncertainty of the experimental results.

  9. Hepatic Falciform Ligament Artery in Patients with Chronic Liver Diseases: Detection on Computed Tomography Hepatic Arteriography

    International Nuclear Information System (INIS)

    Tajima, T.; Yoshimitsu, K.; Irie, H.; Nishie, A.; Hirakawa, M.; Ishigami, K.; Ushijima, Y.; Okamoto, D.; Honda, H.

    2009-01-01

    Background: The detection rate of hepatic falciform ligament artery (FLA) has been reported as ranging from 2-25%. The rate of FLA on laparotomy, however, is reported to be higher, at 68%. Purpose: To compare the detection rate of FLA on computed tomography hepatic arteriography (CTHA) with that on angiography and dynamic CT, and to clarify the clinical significance of FLA in patients with chronic liver disease. Material and Methods: 126 consecutive patients underwent CTHA angiography and dynamic CT to evaluate suspected liver tumors. Liver function was classified as follows: normal, n=5; Child-Pugh class A, n=94; B, n=21; and C, n=6. All CT images were obtained using multidetector (MDCT) scanners (Aquilion; Toshiba, Tokyo (JP)). For CTHA, CT images were obtained during contrast material injection through the left hepatic, proper, or common hepatic artery. On CT, FLAs were retrospectively identified within the hepatic falciform ligament and the hepatic round ligament by the paging method on a workstation (TWS-5000; Toshiba, Tokyo (JP)). The detection rates were compared among the three modalities (hepatic arterial phase of dynamic CT, CTHA, and angiography). The calibers of FLA were also correlated with the hepatic function of the patients. Results: The detection rates of FLA by angiography, dynamic CT, and CTHA were 37% (47/126), 10% (13/126), and 77% (97/126), respectively. The calibers of FLA increased as the hepatic function deteriorated (P=0.001). Conclusion: The detection rates of FLA with CTHA are far higher than those with angiography and dynamic CT. Careful interpretation with recognition of FLA on CTHA images is important, as inadvertent embolization or chemotherapeutic infusion of the FLA may result in supraumbilical skin rash

  10. Emotional Competence and Drop-Out Rates in Higher Education

    Science.gov (United States)

    Kingston, Emma

    2008-01-01

    Purpose: The purpose of this paper is to compare the emotional competence of first year undergraduates enrolled on a high or low drop-out rate (HDR and LDR, respectively) course, at a newly established university within the UK. Design/methodology/approach: A mixed methods approach using both quantitative and qualitative data collection methods was…

  11. Standoff detection of turbulent chemical mixture plumes using a swept external cavity quantum cascade laser

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Mark C. [Pacific Northwest National Laboratory, Richland, Washington; Brumfield, Brian E. [Pacific Northwest National Laboratory, Richland, Washington

    2017-08-21

    We demonstrate standoff detection of turbulent mixed-chemical plumes using a broadly-tunable external cavity quantum cascade laser (ECQCL). The ECQCL was directed through plumes of mixed methanol/ethanol vapor to a partially-reflective surface located 10 m away. The reflected power was measured as the ECQCL was swept over its tuning range of 930-1065 cm-1 (9.4-10.8 µm) at rates up to 200 Hz. Analysis of the transmission spectra though the plume was performed to determine chemical concentrations with time resolution of 0.005 s. Comparison of multiple spectral sweep rates of 2 Hz, 20 Hz, and 200 Hz shows that higher sweep rates reduce effects of atmospheric and source turbulence, resulting in lower detection noise and more accurate measurement of the rapidly-changing chemical concentrations. Detection sensitivities of 0.13 ppm*m for MeOH and 1.2 ppm*m for EtOH are demonstrated for a 200 Hz spectral sweep rate, normalized to 1 s detection time.

  12. Diagnostic value of multi-tumor markers protein biochip detection for primary pulmonary cancer

    International Nuclear Information System (INIS)

    Xu Fengpo; Wu Yiwei; Li Qingru; Fa Yihua

    2005-01-01

    To evaluate the diagnostic value of multi-tumor markers protein biochip detection for primary pulmonary cancer, 12 tumor markers including AFP, CEA, NSE, CA125, CA15-3, CA242, CA19-9, PSA, f-PSA, FER, β-HCG and HGH were measured by the protein biochip in the serum of 45 primary pulmonary cancer patients. Positive rate of tumor markers was FER (42.2%), CEA (35.6%), CA125 (24.4%), CA15-3 (17.8%), CA242 (13.3%), CA19-9 (11.1%), β-HCG(8.9%), HGH(6.7%), NSE(4.4%), AFP (0), f-PSA (0) and PSA (0), respectively. The rate of patients with one abnorma indicator was 57.8% except FER. The positive rate using multi-tumor markers protein biochip detection was significantly higher than that of single tumor marker detective method, and this detection can be used for the diagnosis of patients with primary pulmonary cancer. (authors)

  13. The Montreal Cognitive Assessment is superior to the Mini-Mental State Examination in detecting patients at higher risk of dementia.

    Science.gov (United States)

    Dong, YanHong; Lee, Wah Yean; Basri, Nur Adilah; Collinson, Simon Lowes; Merchant, Reshma A; Venketasubramanian, Narayanaswamy; Chen, Christopher Li-Hsian

    2012-11-01

    To examine the discriminant validity of the Montreal Cognitive Assessment (MoCA) and the Mini-Mental State Examination (MMSE) in detecting patients with cognitive impairment at higher risk for dementia at a memory clinic setting. Memory clinic patients were administered the MoCA, MMSE, and a comprehensive formal neuropsychological battery. Mild cognitive impairment (MCI) subtypes were dichotomized into two groups: single domain-MCI (sd-MCI) and multiple domain-MCI (md-MCI). Area under the receiver operating characteristic curve (ROC) analysis was used to compare the discriminatory ability of the MoCA and the MMSE. Two hundred thirty patients were recruited, of which 136 (59.1%) were diagnosed with dementia, 61 (26.5%) with MCI, and 33 (14.3%) with no cognitive impairment (NCI). The majority of MCI patients had md-MCI (n = 36, 59%). The MoCA had significantly larger AUCs than the MMSE in discriminating md-MCI from the lower risk group for incident dementia (NCI and sd-MCI) [MoCA 0.92 (95% CI, 0.86-0.98) vs. MMSE 0.84 (95% CI, 0.75-0.92), p = 0.02). At their optimal cut-off points, the MoCA (19/20) remained superior to the MMSE (23/24) in detecting md-MCI [sensitivity: 0.83 vs. 0.72; specificity: 0.86 vs. 0.83; PPV: 0.79 vs. 0.72; NPV: 0.89 vs. 0.83; correctly classified: 85.1% vs. 78.7%]. The MoCA is superior to the MMSE in the detection of patients with cognitive impairment at higher risk for incident dementia at a memory clinic setting.

  14. PSA-stratified detection rates for [68Ga]THP-PSMA, a novel probe for rapid kit-based 68Ga-labeling and PET imaging, in patients with biochemical recurrence after primary therapy for prostate cancer.

    Science.gov (United States)

    Derlin, Thorsten; Schmuck, Sebastian; Juhl, Cathleen; Zörgiebel, Johanna; Schneefeld, Sophie M; Walte, Almut C A; Hueper, Katja; von Klot, Christoph A; Henkenberens, Christoph; Christiansen, Hans; Thackeray, James T; Ross, Tobias L; Bengel, Frank M

    2018-06-01

    [ 68 Ga]Tris(hydroxypyridinone)(THP)-PSMA is a novel radiopharmaceutical for one-step kit-based radiolabelling, based on direct chelation of 68 Ga 3+ at low concentration, room temperature and over a wide pH range, using direct elution from a 68 Ge/ 68 Ga-generator. We evaluated the clinical detection rates of [ 68 Ga]THP-PSMA PET/CT in patients with biochemically recurrent prostate cancer after prostatectomy. Consecutive patients (n=99) referred for evaluation of biochemical relapse of prostate cancer by [ 68 Ga]THP-PSMA PET/CT were analyzed retrospectively. Patients underwent a standard whole-body PET/CT (1 h p.i.), followed by delayed (3 h p.i.) imaging of the abdomen. PSA-stratified cohorts of positive PET/CT results, standardized uptake values (SUVs) and target-to-background ratios (TBRs) were analyzed, and compared between standard and delayed imaging. At least one lesion suggestive of recurrent or metastatic prostate cancer was identified on PET images in 52 patients (52.5%). Detection rates of [ 68 Ga]THP-PSMA PET/CT increased with increasing PSA level: 94.1% for a PSA value of ≥10 ng/mL, 77.3% for a PSA value of 2 to PSA value of 1 to PSA value of 0.5 to PSA value of >0.2 to PSA value of 0.01 to 0.2 ng/mL. [ 68 Ga]THP-PSMA uptake (SUVs) in metastases decreased over time, whereas TBRs improved. Delayed imaging at 3 h p.i. exclusively identified pathologic findings in 2% of [ 68 Ga]THP-PSMA PET/CT scans. Detection rate was higher in patients with a Gleason score ≥8 (P=0.02) and in patients receiving androgen deprivation therapy (P=0.003). In this study, [ 68 Ga]THP-PSMA PET/CT showed suitable detection rates in patients with biochemical recurrence of prostate cancer and PSA levels ≥ 2 ng /mL. Detections rates were lower than in previous studies evaluating other PSMA ligands, though prospective direct radiotracer comparison studies are mandatory particularly in patients with low PSA levels to evaluate the relative performance of different PSMA ligands.

  15. Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale.

    Science.gov (United States)

    Diaz, Delia H; Casas, Oscar; Pallas-Areny, Ramon

    2010-01-01

    Electronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart rate, cardiac output and systolic blood pressure. Therefore, weighing scales may suit intermittent monitoring in e-health and patient screening. Scales intended for bioelectrical impedance analysis (BIA) have also been proposed to estimate the heart rate by amplifying the pulsatile impedance component superimposed on the basal impedance. However, electronic weighing scales cannot easily obtain the BCG from people that have a single leg neither are bioimpedance measurements between both feet recommended for people wearing a pacemaker or other electronic implants, neither for pregnant women. We propose a method to detect the heart rate (HR) from bioimpedance measured in a single foot while standing on an bathroom weighting scale intended for BIA. The electrodes built in the weighing scale are used to apply a 50 kHz voltage between the outer electrode pair and to measure the drop in voltage across the inner electrode pair. The agreement with the HR simultaneously obtained from the ECG is excellent. We have also compared the drop in voltage across the waist and the thorax with that obtained when measuring bioimpedance between both feet to compare the possible risk of the proposed method to that of existing BIA scales.

  16. Susceptibility of Biomphalaria tenagophila and Biomphalaria straminea to Schistosoma mansoni infection detected by low stringency polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    JANNOTTI-PASSOS Liana Konovaloff

    2000-01-01

    Full Text Available In order to determine Schistosoma mansoni infection rates in Biomphalaria tenagophila and B. straminea, low stringency polymerase chain reaction (LS-PCR technique was used as a complementary method to light exposure technique. LS-PCR has already been standardized in our laboratory to detect the trematode DNA in B. glabrata. Higher S. mansoni infection rates were detected using conventional method and LS-PCR. The parasite DNA profile was detected in both species after 7-day exposure to miracidia, using LS-PCR. This technique enables early detection of schistosomiasis transmission focuses, in endemic areas, before the beginning of cercariae shedding.

  17. Constraints on the bulk Lorentz factor of gamma-ray bursts with the detection rate by Fermi LAT

    Science.gov (United States)

    Chen, Ye; Liu, Ruo-Yu; Wang, Xiang-Yu

    2018-05-01

    The bulk Lorentz factor(Γ) of the outflow is an essential parameter to understanding the physics of gamma-ray burst (GRB). Informations about the Lorentz factors of some individual GRBs have been obtained from the spectral features of the high-energy gamma-ray emissions (>100 MeV), assuming that the spectral breaks or cutoffs are due to the pair-production attenuation (i.e., γγ → e+e-). In this paper, we attempt to interpret the dependence of the LAT detection rate of GRBs on the number of high-energy gamma-rays, taking into account the attenuation effect. We first simulate a long-GRB sample with Monte Carlo method using the luminosity function, rate distribution with redshift and properties of the GRB spectrum. To characterize the distribution of the Lorentz factors, we assume that the Lorentz factors follow the relation Γ =Γ _0E_iso,52k, where Eiso, 52 is the isotropic photon energy in unit of 1052erg. After taking into account the attenuation effect related with the above Lorentz factor distribution, we are able to reproduce the LAT-detected rate of GRBs as the function of the number of gamma-rays for suitable choice of the values of Γ0 and k. The result suggests that the distribution of the bulk Lorentz factor for the majority of GRBs is in the range of 50 - 250.

  18. Bit-error-rate performance analysis of self-heterodyne detected radio-over-fiber links using phase and intensity modulation

    DEFF Research Database (Denmark)

    Yin, Xiaoli; Yu, Xianbin; Tafur Monroy, Idelfonso

    2010-01-01

    We theoretically and experimentally investigate the performance of two self-heterodyne detected radio-over-fiber (RoF) links employing phase modulation (PM) and quadrature biased intensity modulation (IM), in term of bit-error-rate (BER) and optical signal-to-noise-ratio (OSNR). In both links, self...

  19. Low-Complexity Variable Frame Rate Analysis for Speech Recognition and Voice Activity Detection

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Lindberg, Børge

    2010-01-01

    present a low-complexity and effective frame selection approach based on a posteriori signal-to-noise ratio (SNR) weighted energy distance: The use of an energy distance, instead of e.g. a standard cepstral distance, makes the approach computationally efficient and enables fine granularity search......Frame based speech processing inherently assumes a stationary behavior of speech signals in a short period of time. Over a long time, the characteristics of the signals can change significantly and frames are not equally important, underscoring the need for frame selection. In this paper, we......, and the use of a posteriori SNR weighting emphasizes the reliable regions in noisy speech signals. It is experimentally found that the approach is able to assign a higher frame rate to fast changing events such as consonants, a lower frame rate to steady regions like vowels and no frames to silence, even...

  20. Analysis of the population at high risk of stroke detected with carotid artery ultrasonography in Tianjin urban communities

    Directory of Open Access Journals (Sweden)

    Wei YUE

    2015-04-01

    Full Text Available Objective To investigate the features of carotid atherosclerosis in a population at high risk of stroke in urban communities of Tianjin, so as to provide inspiration for carotid ultrasonography to play a greater role in the prevention and control of stroke.  Methods A total of 956 residents at high risk of stroke were selected from 4 urban communities in Tianjin using cluster random sampling method. Doppler ultrasound screening was performed in bilateral common carotid artery (CCA, internal carotid artery (ICA, external carotid artery (ECA, vertebral artery (VA, subclavian artery (SCA and innominate artery of the population. The intima-media thickness (IMT, atherosclerotic plaque formation and its location and size, vascular stenosis or occlusion, and flow spectrum were detected. The results and features of carotid ultrasound screening were analyzed and compared among different gender and age groups.  Results 1 The detection rate of carotid atherosclerosis was 71.55% (684/956, and the detection rate in males was significantly higher than that in females (79.08% vs 65.87%; χ2 = 20.067, P = 0.000. 2 Among the population with carotid atherosclerosis, the most common manifestation was the formation of atherosclerotic plaques (81.58%, 558/684, secondly intima-media thickening (13.01%, 89/684, followed by moderate to severe stenosis or occlusion (5.41%, 37/684. The proportion of intima-media thickening in males was lower than that in females (7.08% vs 18.38%; χ2 = 19.269, P = 0.000. The proportion of carotid atherosclerotic plaque formation in males was higher than that in females (86.46% vs 77.16%; χ2 = 9.824, P = 0.002. The median rating of carotid atherosclerosis was 1.79, with males higher than females [1.98 (0.70, 3.26 vs 1.52 (0.20, 2.84; Z = 2.304, P = 0.042]. The site of plaque formation was most commonly located in carotid bulb (36.61%, secondly SCA (22.18%. Of the type of carotid stenosis, ICA stenosis was detected in 30 cases, VA

  1. Mutation rate estimation for 15 autosomal STR loci in a large population from Mainland China.

    Science.gov (United States)

    Zhao, Zhuo; Zhang, Jie; Wang, Hua; Liu, Zhi-Peng; Liu, Ming; Zhang, Yuan; Sun, Li; Zhang, Hui

    2015-09-01

    STR, short tandem repeats, are well known as a type of powerful genetic marker and widely used in studying human population genetics. Compared with the conventional genetic markers, the mutation rate of STR is higher. Additionally, the mutations of STR loci do not lead to genetic inconsistencies between the genotypes of parents and children; therefore, the analysis of STR mutation is more suited to assess the population mutation. In this study, we focused on 15 autosomal STR loci. DNA samples from a total of 42,416 unrelated healthy individuals (19,037 trios) from the population of Mainland China collected between Jan 2012 and May 2014 were successfully investigated. In our study, the allele frequencies, paternal mutation rates, maternal mutation rates and average mutation rates were detected. Furthermore, we also investigated the relationship between paternal ages, maternal ages, area, the time of pregnancy and average mutation rate. We found that the paternal mutation rate was higher than the maternal mutation rate and the paternal, maternal, and average mutation rates had a positive correlation with paternal age, maternal age and the time of pregnancy respectively. Additionally, the average mutation rate of coastal areas was higher than that of inland areas.

  2. Higher USA State Resident Neuroticism Is Associated With Lower State Volunteering Rates.

    Science.gov (United States)

    McCann, Stewart J H

    2017-12-01

    Highly neurotic persons have dispositional characteristics that tend to precipitate social anxiety that discourages formal volunteering. With the 50 American states as analytical units, Study 1 found that state resident neuroticism correlated highly ( r = -.55) with state volunteering rates and accounted for another 26.8% of the volunteering rate variance with selected state demographics controlled. Study 2 replicated Study 1 during another period and extended the association to college student, senior, secular, and religious volunteering rates. Study 3 showed state resident percentages engaged in other social behaviors involving more familiarity and fewer demands than formal volunteering related to state volunteering rates but not to neuroticism. In Study 4, state resident neuroticism largely accounted statistically for relations between state volunteering rates and state population density, collectivism, social capital, Republican preference, and well-being. This research is the first to show that state resident neuroticism is a potent predictor of state volunteering rates.

  3. Does higher income inequality adversely influence infant mortality rates? Reconciling descriptive patterns and recent research findings.

    Science.gov (United States)

    Siddiqi, Arjumand; Jones, Marcella K; Erwin, Paul Campbell

    2015-04-01

    As the struggle continues to explain the relatively high rates of infant mortality (IMR) exhibited in the United States, a renewed emphasis is being placed on the role of possible 'contextual' determinants. Cross-sectional and short time-series studies have found that higher income inequality is associated with higher IMR at the state level. Yet, descriptively, the longer-term trends in income inequality and in IMR seem to call such results into question. To assess whether, over the period 1990-2007, state-level income inequality is associated with state-level IMR; to examine whether the overall effect of income inequality on IMR over this period varies by state; to test whether the association between income inequality and IMR varies across this time period. IMR data--number of deaths per 1000 live births in a given state and year--were obtained from the U.S. Centers for Disease Control Wonder database. Income inequality was measured using the Gini coefficient, which varies from zero (complete equality) to 100 (complete inequality). Covariates included state-level poverty rate, median income, and proportion of high school graduates. Fixed and random effects regressions were conducted to test hypotheses. Fixed effects models suggested that, overall, during the period 1990-2007, income inequality was inversely associated with IMR (β = -0.07, SE (0.01)). Random effects models suggested that when the relationship was allowed to vary at the state-level, it remained inverse (β = -0.05, SE (0.01)). However, an interaction between income inequality and time suggested that, as time increased, the effect of income inequality had an increasingly positive association with total IMR (β = 0.009, SE (0.002)). The influence of state income inequality on IMR is dependent on time, which may proxy for time-dependent aspects of societal context. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. A COMPARATIVE ANALYSIS OF SINGLE AND COMBINATION FEATURE EXTRACTION TECHNIQUES FOR DETECTING CERVICAL CANCER LESIONS

    Directory of Open Access Journals (Sweden)

    S. Pradeep Kumar Kenny

    2016-02-01

    Full Text Available Cervical cancer is the third most common form of cancer affecting women especially in third world countries. The predominant reason for such alarming rate of death is primarily due to lack of awareness and proper health care. As they say, prevention is better than cure, a better strategy has to be put in place to screen a large number of women so that an early diagnosis can help in saving their lives. One such strategy is to implement an automated system. For an automated system to function properly a proper set of features have to be extracted so that the cancer cell can be detected efficiently. In this paper we compare the performances of detecting a cancer cell using a single feature versus a combination feature set technique to see which will suit the automated system in terms of higher detection rate. For this each cell is segmented using multiscale morphological watershed segmentation technique and a series of features are extracted. This process is performed on 967 images and the data extracted is subjected to data mining techniques to determine which feature is best for which stage of cancer. The results thus obtained clearly show a higher percentage of success for combination feature set with 100% accurate detection rate.

  5. A Comparative Survey of Methods for Remote Heart Rate Detection From Frontal Face Videos

    Directory of Open Access Journals (Sweden)

    Chen Wang

    2018-05-01

    Full Text Available Remotely measuring physiological activity can provide substantial benefits for both the medical and the affective computing applications. Recent research has proposed different methodologies for the unobtrusive detection of heart rate (HR using human face recordings. These methods are based on subtle color changes or motions of the face due to cardiovascular activities, which are invisible to human eyes but can be captured by digital cameras. Several approaches have been proposed such as signal processing and machine learning. However, these methods are compared with different datasets, and there is consequently no consensus on method performance. In this article, we describe and evaluate several methods defined in literature, from 2008 until present day, for the remote detection of HR using human face recordings. The general HR processing pipeline is divided into three stages: face video processing, face blood volume pulse (BVP signal extraction, and HR computation. Approaches presented in the paper are classified and grouped according to each stage. At each stage, algorithms are analyzed and compared based on their performance using the public database MAHNOB-HCI. Results found in this article are limited on MAHNOB-HCI dataset. Results show that extracted face skin area contains more BVP information. Blind source separation and peak detection methods are more robust with head motions for estimating HR.

  6. Increased detection rate of syringomyelia by whole spine sagittal magnetic resonance images: Based on the data from military conscription of Korean young males

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok; Oh, Chang Hyun [Seoul Regional Military Manpower Administration, Seoul (Korea, Republic of); Yoon, Seung Hwan; Park, Hyeong Chun; Park, Chong Oon; Kim, Yeo Ju [Inha Univ. Hospital/College of Medicine/Inha Univ., Incheon (Korea, Republic of)

    2012-09-15

    We compared the detection rate of syringomyelia according to the type of magnetic resonance (MR) images among the Korean military conscription. Among the total of 238910 examinees (males aged 18 to 32 years old) from January 2008 to December 2011, the examinees with conventional single lesion MR images (cervical, thoracic, and lumbar) with and without whole spine sagittal T2 weighted MR images (WSST2I) totaled 1206 cases, and syringomyelia was observed in 24 cases. The detection rate of syringomyelia according to the MR protocol (the presence of WSST2I or not) was done through analysis by annually and the clinical characters of syringomyelia was reviewed. The estimated prevalence of syringomyelia was approximately 10.0 cases per 100000 people. The detection rate was increased annually when the WSST2I proportion was increased (from 3.4 to 14.9 cases per 100000 persons, r = 0.939, p = 0.018). Clinical character of syringomyelia was ambiguous with other spinal diseases. The most affected spinal level was C5 to C7 (83%), and most cases were non communicating syringomyelia with benign central canal widening (79%). Whole spine sagittal MR image is useful to detect coexisting spinal diseases such as syringomyelia, and most syringomyelia in young males was benign hydromyelia. A whole spine sagittal MR image is recommended to increase the detection of syringomyelia.

  7. An Examination of Three Spatial Event Cluster Detection Methods

    Directory of Open Access Journals (Sweden)

    Hensley H. Mariathas

    2015-03-01

    Full Text Available In spatial disease surveillance, geographic areas with large numbers of disease cases are to be identified, so that targeted investigations can be pursued. Geographic areas with high disease rates are called disease clusters and statistical cluster detection tests are used to identify geographic areas with higher disease rates than expected by chance alone. In some situations, disease-related events rather than individuals are of interest for geographical surveillance, and methods to detect clusters of disease-related events are called event cluster detection methods. In this paper, we examine three distributional assumptions for the events in cluster detection: compound Poisson, approximate normal and multiple hypergeometric (exact. The methods differ on the choice of distributional assumption for the potentially multiple correlated events per individual. The methods are illustrated on emergency department (ED presentations by children and youth (age < 18 years because of substance use in the province of Alberta, Canada, during 1 April 2007, to 31 March 2008. Simulation studies are conducted to investigate Type I error and the power of the clustering methods.

  8. Higher-Order Statistics for the Detection of Small Objects in a Noisy Background Application on Sonar Imaging

    Directory of Open Access Journals (Sweden)

    M. Amate

    2007-01-01

    Full Text Available An original algorithm for the detection of small objects in a noisy background is proposed. Its application to underwater objects detection by sonar imaging is addressed. This new method is based on the use of higher-order statistics (HOS that are locally estimated on the images. The proposed algorithm is divided into two steps. In a first step, HOS (skewness and kurtosis are estimated locally using a square sliding computation window. Small deterministic objects have different statistical properties from the background they are thus highlighted. The influence of the signal-to-noise ratio (SNR on the results is studied in the case of Gaussian noise. Mathematical expressions of the estimators and of the expected performances are derived and are experimentally confirmed. In a second step, the results are focused by a matched filter using a theoretical model. This enables the precise localization of the regions of interest. The proposed method generalizes to other statistical distributions and we derive the theoretical expressions of the HOS estimators in the case of a Weibull distribution (both when only noise is present or when a small deterministic object is present within the filtering window. This enables the application of the proposed technique to the processing of synthetic aperture sonar data containing underwater mines whose echoes have to be detected and located. Results on real data sets are presented and quantitatively evaluated using receiver operating characteristic (ROC curves.

  9. Forecasting the new case detection rate of leprosy in four states of Brazil: A comparison of modelling approaches

    NARCIS (Netherlands)

    D.J. Blok (David); R.E. Crump (Ron E.); Sundaresh, R. (Ram); M. Ndeffo-Mbah (Martial); Galvani, A.P. (Alison P.); T.C. Porco (Travis C.); S.J. de Vlas (Sake); G.F. Medley (Graham F.); J.H. Richardus (Jan Hendrik)

    2017-01-01

    textabstractBackground Brazil has the second highest annual number of new leprosy cases. The aim of this study is to formally compare predictions of future new case detection rate (NCDR) trends and the annual probability of NCDR falling below 10/100,000 of four different modelling approaches in four

  10. Analysis of hybrid subcarrier multiplexing of OCDMA based on single photodiode detection

    Directory of Open Access Journals (Sweden)

    Ahmad N. A. A

    2017-01-01

    Full Text Available This paper analyzes the performance of subcarrier multiplexing (SCM of spectral amplitude coding optical code multiple access (SAC-OCDMA by applying Recursive Combinatorial (RC code based on single photodiode detection (SPD. SPD is used in the receiver part to reduce the effect of multiple access interference (MAI which contributes as a dominant noise in incoherent SAC-OCDMA systems. Results indicate that the SCM OCDMA network performance could be improved by using lower data rates and higher number of weight. Total number of users can also be enhanced by adding lower data rates and higher number of subcarriers.

  11. Analysis of hybrid subcarrier multiplexing of OCDMA based on single photodiode detection

    Science.gov (United States)

    Ahmad, N. A. A.; Junita, M. N.; Aljunid, S. A.; Rashidi, C. B. M.; Endut, R.

    2017-11-01

    This paper analyzes the performance of subcarrier multiplexing (SCM) of spectral amplitude coding optical code multiple access (SAC-OCDMA) by applying Recursive Combinatorial (RC) code based on single photodiode detection (SPD). SPD is used in the receiver part to reduce the effect of multiple access interference (MAI) which contributes as a dominant noise in incoherent SAC-OCDMA systems. Results indicate that the SCM OCDMA network performance could be improved by using lower data rates and higher number of weight. Total number of users can also be enhanced by adding lower data rates and higher number of subcarriers.

  12. Predicting higher education graduation rates from institutional characteristics and resource allocation

    OpenAIRE

    Florence A. Hamrick; John H. Schuh; Mack C. Shelley

    2004-01-01

    This study incorporated institutional characteristics (e.g., Carnegie type, selectivity) and resource allocations (e.g., instructional expenditures, student affairs expenditures) into a statistical model to predict undergraduate graduation rates. Instructional expenditures, library expenditures, and a number of institutional classification variables were significant predictors of graduation rates. Based on these results, recommendations as well as warranted cautions are included about allocat...

  13. Decreased growth rate of P. falciparum blood stage parasitemia with age in a holoendemic population.

    Science.gov (United States)

    Pinkevych, Mykola; Petravic, Janka; Chelimo, Kiprotich; Vulule, John; Kazura, James W; Moormann, Ann M; Davenport, Miles P

    2014-04-01

    In malaria holoendemic settings, decreased parasitemia and clinical disease is associated with age and cumulative exposure. The relative contribution of acquired immunity against various stages of the parasite life cycle is not well understood. In particular, it is not known whether changes in infection dynamics can be best explained by decreasing rates of infection, or by decreased growth rates of parasites in blood. Here, we analyze the dynamics of Plasmodium falciparum infection after treatment in a cohort of 197 healthy study participants of different ages. We use both polymerase chain reaction (PCR) and microscopy detection of parasitemia in order to understand parasite growth rates and infection rates over time. The more sensitive PCR assay detects parasites earlier than microscopy, and demonstrates a higher overall prevalence of infection than microscopy alone. The delay between PCR and microscopy detection is significantly longer in adults compared with children, consistent with slower parasite growth with age. We estimated the parasite multiplication rate from delay to PCR and microscopy detections of parasitemia. We find that both the delay between PCR and microscopy infection as well as the differing reinfection dynamics in different age groups are best explained by a slowing of parasite growth with age.

  14. Vigorous physical activity predicts higher heart rate variability among younger adults.

    Science.gov (United States)

    May, Richard; McBerty, Victoria; Zaky, Adam; Gianotti, Melino

    2017-06-14

    Baseline heart rate variability (HRV) is linked to prospective cardiovascular health. We tested intensity and duration of weekly physical activity as predictors of heart rate variability in young adults. Time and frequency domain indices of HRV were calculated based on 5-min resting electrocardiograms collected from 82 undergraduate students. Hours per week of both moderate and vigorous activity were estimated using the International Physical Activity Questionnaire. In regression analyses, hours of vigorous physical activity, but not moderate activity, significantly predicted greater time domain and frequency domain indices of heart rate variability. Adjusted for weekly frequency, greater daily duration of vigorous activity failed to predict HRV indices. Future studies should test direct measurements of vigorous activity patterns as predictors of autonomic function in young adulthood.

  15. Assessing the role of spectral and intensity cues in spectral ripple detection and discrimination in cochlear-implant users.

    Science.gov (United States)

    Anderson, Elizabeth S; Oxenham, Andrew J; Nelson, Peggy B; Nelson, David A

    2012-12-01

    Measures of spectral ripple resolution have become widely used psychophysical tools for assessing spectral resolution in cochlear-implant (CI) listeners. The objective of this study was to compare spectral ripple discrimination and detection in the same group of CI listeners. Ripple detection thresholds were measured over a range of ripple frequencies and were compared to spectral ripple discrimination thresholds previously obtained from the same CI listeners. The data showed that performance on the two measures was correlated, but that individual subjects' thresholds (at a constant spectral modulation depth) for the two tasks were not equivalent. In addition, spectral ripple detection was often found to be possible at higher rates than expected based on the available spectral cues, making it likely that temporal-envelope cues played a role at higher ripple rates. Finally, spectral ripple detection thresholds were compared to previously obtained speech-perception measures. Results confirmed earlier reports of a robust relationship between detection of widely spaced ripples and measures of speech recognition. In contrast, intensity difference limens for broadband noise did not correlate with spectral ripple detection measures, suggesting a dissociation between the ability to detect small changes in intensity across frequency and across time.

  16. Rate adaptive multilevel coded modulation with high coding gain in intensity modulation direct detection optical communication

    Science.gov (United States)

    Xiao, Fei; Liu, Bo; Zhang, Lijia; Xin, Xiangjun; Zhang, Qi; Tian, Qinghua; Tian, Feng; Wang, Yongjun; Rao, Lan; Ullah, Rahat; Zhao, Feng; Li, Deng'ao

    2018-02-01

    A rate-adaptive multilevel coded modulation (RA-MLC) scheme based on fixed code length and a corresponding decoding scheme is proposed. RA-MLC scheme combines the multilevel coded and modulation technology with the binary linear block code at the transmitter. Bits division, coding, optional interleaving, and modulation are carried out by the preset rule, then transmitted through standard single mode fiber span equal to 100 km. The receiver improves the accuracy of decoding by means of soft information passing through different layers, which enhances the performance. Simulations are carried out in an intensity modulation-direct detection optical communication system using MATLAB®. Results show that the RA-MLC scheme can achieve bit error rate of 1E-5 when optical signal-to-noise ratio is 20.7 dB. It also reduced the number of decoders by 72% and realized 22 rate adaptation without significantly increasing the computing time. The coding gain is increased by 7.3 dB at BER=1E-3.

  17. Is the higher rate of parental child homicide in stepfamilies an effect of non-genetic relatedness?

    Institute of Scientific and Technical Information of China (English)

    Hans TEMRIN; Johanna NORDLUND; Mikael RYING; Birgitta S. TULLBERG

    2011-01-01

    In an evolutionary perspective individuals are expected to vary the degree of parental love and care in relation to the fitness value that a child represents. Hence, stepparents are expected to show less solicitude than genetically related parents, and this lack of genetic relatedness has been used to explain the higher frequencies of child abuse and homicide found in stepfamilies.However, other factors than non-genetic relatedness may cause this over-representation in stepfamilies. Here we use a 45-year data set of parental child homicides in Sweden to test two hypotheses related to the higher incidence in stepfamilies: 1) adults in different types of family differ in their general disposition to use violence, and 2) parents are more likely to kill stepchildren than genetically related children. Of the 152 perpetrators in biparental families there was an overrepresentation of perpetrators in stepfamilies (n=27) compared with the general population. We found support for the first hypothesis in that both general and violent crime rates were higher in stepfamilies, both in the general population and among perpetrators of child homicide. However, we found no support for the second hypothesis because of the 27 perpetrators in stepfamilies the perpetrator killed a genetically related child in 13 cases, a stepchild in 13 cases and both types of children in one case. Moreover, out of the 12 families where the perpetrator lived with both stepchildren and genetic children, there was no bias towards killing stepchildren. Thus, we found no evidence for an effect of non-genetic relatedness per se [Current Zoology 57 (3): 253-59, 2011].

  18. Real-time heart rate measurement for multi-people using compressive tracking

    Science.gov (United States)

    Liu, Lingling; Zhao, Yuejin; Liu, Ming; Kong, Lingqin; Dong, Liquan; Ma, Feilong; Pang, Zongguang; Cai, Zhi; Zhang, Yachu; Hua, Peng; Yuan, Ruifeng

    2017-09-01

    The rise of aging population has created a demand for inexpensive, unobtrusive, automated health care solutions. Image PhotoPlethysmoGraphy(IPPG) aids in the development of these solutions by allowing for the extraction of physiological signals from video data. However, the main deficiencies of the recent IPPG methods are non-automated, non-real-time and susceptible to motion artifacts(MA). In this paper, a real-time heart rate(HR) detection method for multiple subjects simultaneously was proposed and realized using the open computer vision(openCV) library, which consists of getting multiple subjects' facial video automatically through a Webcam, detecting the region of interest (ROI) in the video, reducing the false detection rate by our improved Adaboost algorithm, reducing the MA by our improved compress tracking(CT) algorithm, wavelet noise-suppression algorithm for denoising and multi-threads for higher detection speed. For comparison, HR was measured simultaneously using a medical pulse oximetry device for every subject during all sessions. Experimental results on a data set of 30 subjects show that the max average absolute error of heart rate estimation is less than 8 beats per minute (BPM), and the processing speed of every frame has almost reached real-time: the experiments with video recordings of ten subjects under the condition of the pixel resolution of 600× 800 pixels show that the average HR detection time of 10 subjects was about 17 frames per second (fps).

  19. The attendance of women in mammographic early detection programme and the results of the observation of the breast glands condition. 1. The attendance of higher schools female employees in mammography examination

    International Nuclear Information System (INIS)

    Romejko, M.; Kleszczewska, J.; Liszek, A.; Tarlowska, L.; Wronkowski, Z.

    1993-01-01

    The aim of the first part of this work is to assess the attendance in the early detection (mammography) in female employees of Warsaw-based higher schools aged 40-69. During the 4.5 year period (1985-1989) 1325 female employees of higher schools (23.5% of the schools' total employment) turned up to the Female Cancer Prevention Center of The Higher Schools' Medical Center (ZOZ) in Warsaw. Observation of this group continued until June 30, 1992. Majority of the women (56.5%) showed up only once, 21.7% came twice, and 21.8% at least three times. Out of the 1021 women (77% of all the examined female employees) who showed no symptoms in the first test, only 37% came again for the second checkup. Out of the 305 women who had changes detected in their X-ray images, 66% turned up for the second test. 23 women (1.7%) had suspicious mammography results or typical cancer symptoms in the first test. The present work shows that the reason of the insufficient attendance of higher schools' female employees in early detection programs need to be investigated and that a more efficient early detection system must be developed. (author)

  20. Adding Endoscopist-Directed Flexible Endoscopic Evaluation of Swallowing to the Videofluoroscopic Swallowing Study Increased the Detection Rates of Penetration, Aspiration, and Pharyngeal Residue.

    Science.gov (United States)

    Park, Won Young; Lee, Tae Hee; Ham, Nam Seok; Park, Ji Woong; Lee, Yang Gyun; Cho, Sang Jin; Lee, Joon Seong; Hong, Su Jin; Jeon, Seong Ran; Kim, Hyun Gun; Cho, Joo Young; Kim, Jin Oh; Cho, Jun Hyung; Lee, Ji Sung

    2015-09-23

    Currently, the videofluoroscopic swallowing study (VFSS) is the standard tool for evaluating dysphagia. We evaluated whether the addition of endoscopist-directed flexible endoscopic evaluation of swallowing (FEES) to VFSS could improve the detection rates of penetration, aspiration, and pharyngeal residue, compared the diagnostic efficacy between VFSS and endoscopist-directed FEES and assessed the adverse events of the FEES. In single tertiary referral center, a retrospective analysis of prospectively collected data was conducted. Fifty consecutive patients suspected of oropharyngeal dysphagia were enrolled in this study between January 2012 and July 2012. The agreement in the detection of penetration and aspiration between VFSS and FEES of viscous food (κ=0.34; 95% confidence interval [CI], 0.15 to 0.53) and liquid food (κ=0.22; 95% CI, 0.02 to 0.42) was "fair." The agreement in the detection of pharyngeal residue between the two tests was "substantial" with viscous food (κ=0.63; 95% CI, 0.41 to 0.94) and "fair" with liquid food (κ=0.37; 95% CI, 0.10 to 0.63). Adding FEES to VFSS significantly increased the detection rates of penetration, aspiration, and pharyngeal residue. No severe adverse events were noted during FEES, except for two cases of epistaxis, which stopped spontaneously without requiring any packing. This study demonstrated that the addition of endoscopist-directed FEES to VFSS increased the detection rates of penetration, aspiration, and pharyngeal residue.

  1. A Hybrid Islanding Detection Technique Using Average Rate of Voltage Change and Real Power Shift

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2009-01-01

    The mainly used islanding detection techniques may be classified as active and passive techniques. Passive techniques don't perturb the system but they have larger nondetection znes, whereas active techniques have smaller nondetection zones but they perturb the system. In this paper, a new hybrid...... technique is proposed to solve this problem. An average rate of voltage change (passive technique) has been used to initiate a real power shift (active technique), which changes the eal power of distributed generation (DG), when the passive technique cannot have a clear discrimination between islanding...

  2. Removal of boron(III) by N-methylglucamine-type cellulose derivatives with higher adsorption rate

    International Nuclear Information System (INIS)

    Inukai, Yoshinari; Tanaka, Yoshiharu; Matsuda, Toshio; Mihara, Nobutake; Yamada, Kouji; Nambu, Nobuyoshi; Itoh, Osamu; Doi, Takao; Kaida, Yasuhiko; Yasuda, Seiji

    2004-01-01

    To obtain adsorbents for boron(III) derived from a natural polymer, two forms (powder and fiber) of N-methylglucamine-type cellulose derivatives were newly synthesized. After the graft polymerization of two forms of cellulose with vinyl monomer having epoxy groups, the N-methylglucamine-type cellulose derivatives were obtained by the reaction of the grafted cellulose with N-methylglucamine. The adsorption capacities of the cellulose derivatives for boron(III) were the same levels as that of a commercially available N-methylglucamine-type polystyrene resin. However, the cellulose derivatives adsorbed boron(III) more quickly than the polystyrene resin. The adsorption and desorption of boron(III) with a column method using the cellulose fiber were achieved at a higher flow rate than that using the polystyrene resin. In addition, the boron(III), adsorbed on the cellulose fiber column, was quantitatively recovered with dilute hydrochloric acid in 20- and 200-fold increased concentrations. Consequently, it was found that the cellulose derivatives were superior to the polystyrene resin as adsorbents for boron(III) for treatment of a large quantity of wastewater

  3. Application of Food-specific IgG Antibody Detection in Allergy Dermatosis

    Directory of Open Access Journals (Sweden)

    Yine Hu

    2015-01-01

    Full Text Available The application of food-specific IgG antibody detection in allergy dermatoses was explored. 181 patients with allergy dermatoses were diagnosed from January to September 2014 and 20 healthy subjects were selected. Fourteen kinds of food-specific IgG antibodies were detected by ELISA method among all the subjects. The positive rates of IgG antibody of the patient group and the healthy group were respectively 65.2% and 5.0%. The positive rates of IgG antibody of egg, milk, shrimp and crab took a large proportion in three groups of patients with three kinds of allergy dermatoses of urticaria, eczema and allergic dermatitis, the proportion of which was respectively 70.2%, 77.8% and 71.7%. Among urticaria and allergic dermatitis patients with positive antibody, the positive rate of children was significantly higher than that of adults (p0.05. Allergy dermatoses are closely related to food-specific IgG antibodies, and the allergy dermatoses patients have a high incidence rate of food intolerance; detecting IgG antibody in the serum of patients is of great significance for the diagnosis and treatment of allergy dermatoses.

  4. The effect of changing from one to two views at incident (subsequent) screens in the NHS breast screening programme in England: impact on cancer detection and recall rates

    International Nuclear Information System (INIS)

    Blanks, R.G.; Bennett, R.L.; Patnick, J.; Cush, S.; Davison, C.; Moss, S.M.

    2005-01-01

    AIM: To assess the effect on cancer detection and recall rates of changing from one to two views for incident (subsequent) screens. METHODS: Controlled, comparative, observational study of programmes in NHS breast screening programme in England. Subjects: women aged 50-64 years were screened by the NHSBSP between 1 April 2001 and 31 March 2003. RESULTS: The effect of changing to two-view mammography was a 20% increase in overall incident screen cancer detection rate, with the biggest effect seen for small (<15 mm) invasive cancers. This increased detection rate was achieved with an 11% drop-in recall rate. CONCLUSION: The introduction of two-view mammography for incident screens has resulted in considerable improvements in overall NHS breast screening performance

  5. Detecting reciprocity at a global scale

    Science.gov (United States)

    Frank, Morgan R.; Obradovich, Nick; Sun, Lijun; Woon, Wei Lee; LeVeck, Brad L.; Rahwan, Iyad

    2018-01-01

    Reciprocity stabilizes cooperation from the level of microbes all the way up to humans interacting in small groups, but does reciprocity also underlie stable cooperation between larger human agglomerations, such as nation states? Famously, evolutionary models show that reciprocity could emerge as a widespread strategy for achieving international cooperation. However, existing studies have only detected reciprocity-driven cooperation in a small number of country pairs. We apply a new method for detecting mutual influence in dynamical systems to a new large-scale data set that records state interactions with high temporal resolution. Doing so, we detect reciprocity between many country pairs in the international system and find that these reciprocating country pairs exhibit qualitatively different cooperative dynamics when compared to nonreciprocating pairs. Consistent with evolutionary theories of cooperation, reciprocating country pairs exhibit higher levels of stable cooperation and are more likely to punish instances of noncooperation. However, countries in reciprocity-based relationships are also quicker to forgive single acts of noncooperation by eventually returning to previous levels of mutual cooperation. By contrast, nonreciprocating pairs are more likely to exploit each other’s cooperation via higher rates of defection. Together, these findings provide the strongest evidence to date that reciprocity is a widespread mechanism for achieving international cooperation. PMID:29326983

  6. Detecting reciprocity at a global scale.

    Science.gov (United States)

    Frank, Morgan R; Obradovich, Nick; Sun, Lijun; Woon, Wei Lee; LeVeck, Brad L; Rahwan, Iyad

    2018-01-01

    Reciprocity stabilizes cooperation from the level of microbes all the way up to humans interacting in small groups, but does reciprocity also underlie stable cooperation between larger human agglomerations, such as nation states? Famously, evolutionary models show that reciprocity could emerge as a widespread strategy for achieving international cooperation. However, existing studies have only detected reciprocity-driven cooperation in a small number of country pairs. We apply a new method for detecting mutual influence in dynamical systems to a new large-scale data set that records state interactions with high temporal resolution. Doing so, we detect reciprocity between many country pairs in the international system and find that these reciprocating country pairs exhibit qualitatively different cooperative dynamics when compared to nonreciprocating pairs. Consistent with evolutionary theories of cooperation, reciprocating country pairs exhibit higher levels of stable cooperation and are more likely to punish instances of noncooperation. However, countries in reciprocity-based relationships are also quicker to forgive single acts of noncooperation by eventually returning to previous levels of mutual cooperation. By contrast, nonreciprocating pairs are more likely to exploit each other's cooperation via higher rates of defection. Together, these findings provide the strongest evidence to date that reciprocity is a widespread mechanism for achieving international cooperation.

  7. Interphase fluorescence in situ hybridization analysis detects a much higher rate of thyroid tumors with clonal cytogenetic deviations of the main cytogenetic subgroups than conventional cytogenetics.

    Science.gov (United States)

    Drieschner, Norbert; Rippe, Volkhard; Laabs, Anne; Dittberner, Lea; Nimzyk, Rolf; Junker, Klaus; Rommel, Birgit; Kiefer, Yvonne; Belge, Gazanfer; Bullerdiek, Jörn; Sendt, Wolfgang

    2011-07-01

    In benign thyroid lesions, three main cytogenetic subgroups, characterized by trisomy 7 or structural aberrations involving either chromosomal region 19q13.4 or 2p21, can be distinguished by conventional cytogenetics (CC). As a rule, these aberrations seem to be mutually exclusive. Interphase fluorescence in situ hybridization (I-FISH) analysis on benign as well as malignant thyroid neoplasias has been performed in the past, but rarely in combination with CC. In the present paper, we have analyzed 161 benign thyroid lesions both with CC and I-FISH on touch preparations by using a multi-target, triple-color FISH assay as well as dual-color break-apart probes for detection of the main cytogenetic subgroups. Within the samples, I-FISH detected tumors belonging to either of the subgroups more frequently than CC (23 vs. 11.4%), either due to small subpopulations of aberrant cells or to cryptic chromosomal rearrangements (three cases). Thus, I-FISH seems to be more sensitive than CC, particularly in the detection of subpopulations of cells harboring cytogenetic aberrations that may be overlooked by CC. In summary, I-FISH on touch preparations of benign thyroid lesions seems to be a favorable method for cytogenetic subtyping of thyroid lesions. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Exploiting Higher Order and Multi-modal Features for 3D Object Detection

    DEFF Research Database (Denmark)

    Kiforenko, Lilita

    that describe object visual appearance such as shape, colour, texture etc. This thesis focuses on robust object detection and pose estimation of rigid objects using 3D information. The thesis main contributions are novel feature descriptors together with object detection and pose estimation algorithms....... The initial work introduces a feature descriptor that uses edge categorisation in combination with a local multi-modal histogram descriptor in order to detect objects with little or no texture or surface variation. The comparison is performed with a state-of-the-art method, which is outperformed...... of the methods work well for one type of objects in a specific scenario, in another scenario or with different objects they might fail, therefore more robust solutions are required. The typical problem solution is the design of robust feature descriptors, where feature descriptors contain information...

  9. Is the higher rate of parental child homicide in stepfamilies an effect of non-genetic relatedness?

    Directory of Open Access Journals (Sweden)

    Hans TEMRIN, Johanna NORDLUND, Mikael RYING, Birgitta S. TULLBERG

    2011-06-01

    Full Text Available In an evolutionary perspective individuals are expected to vary the degree of parental love and care in relation to the fitness value that a child represents. Hence, stepparents are expected to show less solicitude than genetically related parents, and this lack of genetic relatedness has been used to explain the higher frequencies of child abuse and homicide found in stepfamilies. However, other factors than non-genetic relatedness may cause this over-representation in stepfamilies. Here we use a 45-year data set of parental child homicides in Sweden to test two hypotheses related to the higher incidence in stepfamilies: 1 adults in different types of family differ in their general disposition to use violence, and 2 parents are more likely to kill stepchildren than genetically related children. Of the 152 perpetrators in biparental families there was an overrepresentation of perpetrators in stepfamilies (n=27 compared with the general population. We found support for the first hypothesis in that both general and violent crime rates were higher in stepfamilies, both in the general population and among perpetrators of child homicide. However, we found no support for the second hypothesis because of the 27 perpetrators in stepfamilies the perpetrator killed a genetically related child in 13 cases, a stepchild in 13 cases and both types of children in one case. Moreover, out of the 12 families where the perpetrator lived with both stepchildren and genetic children, there was no bias towards killing stepchildren. Thus, we found no evidence for an effect of non-genetic relatedness per se [Current Zoology 57 (3: 253–259, 2011].

  10. Microcontroller based driver alertness detection systems to detect drowsiness

    Science.gov (United States)

    Adenin, Hasibah; Zahari, Rahimi; Lim, Tiong Hoo

    2018-04-01

    The advancement of embedded system for detecting and preventing drowsiness in a vehicle is a major challenge for road traffic accident systems. To prevent drowsiness while driving, it is necessary to have an alert system that can detect a decline in driver concentration and send a signal to the driver. Studies have shown that traffc accidents usually occur when the driver is distracted while driving. In this paper, we have reviewed a number of detection systems to monitor the concentration of a car driver and propose a portable Driver Alertness Detection System (DADS) to determine the level of concentration of the driver based on pixelated coloration detection technique using facial recognition. A portable camera will be placed at the front visor to capture facial expression and the eye activities. We evaluate DADS using 26 participants and have achieved 100% detection rate with good lighting condition and a low detection rate at night.

  11. Early detection of pharmacovigilance signals with automated methods based on false discovery rates: a comparative study.

    Science.gov (United States)

    Ahmed, Ismaïl; Thiessard, Frantz; Miremont-Salamé, Ghada; Haramburu, Françoise; Kreft-Jais, Carmen; Bégaud, Bernard; Tubert-Bitter, Pascale

    2012-06-01

    Improving the detection of drug safety signals has led several pharmacovigilance regulatory agencies to incorporate automated quantitative methods into their spontaneous reporting management systems. The three largest worldwide pharmacovigilance databases are routinely screened by the lower bound of the 95% confidence interval of proportional reporting ratio (PRR₀₂.₅), the 2.5% quantile of the Information Component (IC₀₂.₅) or the 5% quantile of the Gamma Poisson Shrinker (GPS₀₅). More recently, Bayesian and non-Bayesian False Discovery Rate (FDR)-based methods were proposed that address the arbitrariness of thresholds and allow for a built-in estimate of the FDR. These methods were also shown through simulation studies to be interesting alternatives to the currently used methods. The objective of this work was twofold. Based on an extensive retrospective study, we compared PRR₀₂.₅, GPS₀₅ and IC₀₂.₅ with two FDR-based methods derived from the Fisher's exact test and the GPS model (GPS(pH0) [posterior probability of the null hypothesis H₀ calculated from the Gamma Poisson Shrinker model]). Secondly, restricting the analysis to GPS(pH0), we aimed to evaluate the added value of using automated signal detection tools compared with 'traditional' methods, i.e. non-automated surveillance operated by pharmacovigilance experts. The analysis was performed sequentially, i.e. every month, and retrospectively on the whole French pharmacovigilance database over the period 1 January 1996-1 July 2002. Evaluation was based on a list of 243 reference signals (RSs) corresponding to investigations launched by the French Pharmacovigilance Technical Committee (PhVTC) during the same period. The comparison of detection methods was made on the basis of the number of RSs detected as well as the time to detection. Results comparing the five automated quantitative methods were in favour of GPS(pH0) in terms of both number of detections of true signals and

  12. Effect of adding screening ultrasonography to screening mammography on patient recall and cancer detection rates: A retrospective study in Japan

    International Nuclear Information System (INIS)

    Tohno, Eriko; Umemoto, Takeshi; Sasaki, Kyoko; Morishima, Isamu; Ueno, Ei

    2013-01-01

    Purpose: To determine whether adding screening ultrasonography to screening mammography can reduce patient recall rates and increase cancer detection rates. Materials and methods: We analyzed the results of mammography and ultrasonography breast screenings performed at the Total Health Evaluation Center Tsukuba, Japan, between April 2011 and March 2012. We also reviewed the modalities and results of diagnostic examinations from women with mammographic abnormalities who visited the Tsukuba Medical Center Hospital for further testing. Results: Of 11,753 women screened, cancer was diagnosed in 10 (0.22%) of the 4529 participants who underwent mammography alone, 23 (0.37%) of the 6250 participants who underwent ultrasonography alone, and 5 (0.51%) of the 974 participants who underwent mammography and ultrasonography. The recall rate due to mammographic abnormalities was 4.9% for women screened only with mammography and 2.6% for those screened with both modalities. The cancer detection rate was 0.22% for women screened only with mammography (positive predictive value, 4.5%) and 0.31% for those screened with both modalities (positive predictive value, 12.0%). Of the 211 lesions presenting as mammographic abnormalities investigated further, diagnostic ultrasonography found no abnormalities in 63 (29.9%) and benign findings in 69 (33.7%). The rest 36.4% needed mammography, cytological or histological examinations or follow-up in addition to diagnostic ultrasonography. Conclusions: It is possible to reduce the recall rate in screening mammography by combining mammography and ultrasonography for breast screening

  13. Back-to-Back Comparison of Auto-Fluorescence Imaging (AFI Versus High Resolution White Light Colonoscopy for Adenoma Detection

    Directory of Open Access Journals (Sweden)

    Moriichi Kentaro

    2012-06-01

    Full Text Available Abstract Background Some patients under close colonoscopic surveillance still develop colorectal cancer, thus suggesting the overlook of colorectal adenoma by endoscopists. AFI detects colorectal adenoma as a clear magenta, therefore the efficacy of AFI is expected to improve the detection ability of colorectal adenoma. The aim of this study is to determine the efficacy of AFI in detecting colorectal adenoma. Methods This study enrolled 88 patients who underwent colonoscopy at Asahikawa Medical University and Kushiro Medical Association Hospital. A randomly selected colonoscopist first observed the sigmoid colon and rectum with conventional high resolution endosopy (HRE. Then the colonoscopist changed the mode to AFI and handed to the scope to another colonoscopist who knew no information about the HRE. Then the second colonoscopist observed the sigmoid colon and rectum. Each colonoscopist separately recorded the findings. The detection rate, miss rate and procedural time were assessed in prospective manner. Results The detection rate of flat and depressed adenoma, but not elevated adenoma, by AFI is significantly higher than that by HRE. In less-experienced endoscopists, AFI dramatically increased the detection rate (30.3% and reduced miss rate (0% of colorectal adenoma in comparison to those of HRE (7.7%, 50.0%, but not for experienced endoscopists. The procedural time of HRE was significantly shorter than that of AFI. Conclusions AFI increased the detection rate and reduced the miss rate of flat and depressed adenomas. These advantages of AFI were limited to less-experienced endoscopists because experienced endoscopists exhibited a substantially high detection rate for colorectal adenoma with HRE.

  14. Understanding recall rates in screening mammography: A conceptual framework review of the literature

    International Nuclear Information System (INIS)

    Mohd Norsuddin, N.; Reed, W.; Mello-Thoms, C.; Lewis, S.J.

    2015-01-01

    Recall rates are one of the performance measures used to evaluate the effectiveness of mammography screening programs. There is conflicting evidence regarding the link between recall rates and cancer detection rates and a variety of differing recall rates exist between countries and readers. This variability in recall rates may have important clinical and economic implications such as unnecessary follow-up procedures, additional costs to the health care system and psychological effects for the women themselves associated with false-positive mammograms results. In order to reduce the impact of false positive recall rates in screening mammography, it is essential for all multidisciplinary health care providers, especially those in medical imaging, to fully understand the factors that may contribute and affect recall rates. The multifactorial nature of recall rates is explored in this paper through the construction of a conceptual map based on a review of the current literature. - Highlights: • Recall rates vary across countries and readers and for initial and subsequent screens. • Falsely recalling women has important clinical, cost and psycho-social implications. • Imaging technology, readers' expertise and patient presentation affect recall rates. • Higher recall rates do not translate into improved sensitivity at higher thresholds. • Multidisciplinary approaches to reduce recall rates may improve women experiences.

  15. Leak Detection Modeling and Simulation for Oil Pipeline with Artificial Intelligence Method

    Directory of Open Access Journals (Sweden)

    Pudjo Sukarno

    2007-05-01

    Full Text Available Leak detection is always interesting research topic, where leak location and leak rate are two pipeline leaking parameters that should be determined accurately to overcome pipe leaking problems. In this research those two parameters are investigated by developing transmission pipeline model and the leak detection model which is developed using Artificial Neural Network. The mathematical approach needs actual leak data to train the leak detection model, however such data could not be obtained from oil fields. Therefore, for training purposes hypothetical data are developed using the transmission pipeline model, by applying various physical configuration of pipeline and applying oil properties correlations to estimate the value of oil density and viscosity. The various leak locations and leak rates are also represented in this model. The prediction of those two leak parameters will be completed until the total error is less than certain value of tolerance, or until iterations level is reached. To recognize the pattern, forward procedure is conducted. The application of this approach produces conclusion that for certain pipeline network configuration, the higher number of iterations will produce accurate result. The number of iterations depend on the leakage rate, the smaller leakage rate, the higher number of iterations are required. The accuracy of this approach is clearly determined by the quality of training data. Therefore, in the preparation of training data the results of pressure drop calculations should be validated by the real measurement of pressure drop along the pipeline. For the accuracy purposes, there are possibility to change the pressure drop and fluid properties correlations, to get the better results. The results of this research are expected to give real contribution for giving an early detection of oil-spill in oil fields.

  16. Comparing Automatic CME Detections in Multiple LASCO and SECCHI Catalogs

    Energy Technology Data Exchange (ETDEWEB)

    Hess, Phillip [NRC Research Associate, U.S. Naval Research Laboratory, Washington, DC (United States); Colaninno, Robin C., E-mail: phillip.hess.ctr@nrl.navy.mil, E-mail: robin.colaninno@nrl.navy.mil [U.S. Naval Research Laboratory, Washington, DC (United States)

    2017-02-10

    With the creation of numerous automatic detection algorithms, a number of different catalogs of coronal mass ejections (CMEs) spanning the entirety of the Solar and Heliospheric Observatory ( SOHO ) Large Angle Spectrometric Coronagraph (LASCO) mission have been created. Some of these catalogs have been further expanded for use on data from the Solar Terrestrial Earth Observatory ( STEREO ) Sun Earth Connection Coronal and Heliospheric Investigation (SECCHI) as well. We compare the results from different automatic detection catalogs (Solar Eruption Event Detection System (SEEDS), Computer Aided CME Tracking (CACTus), and Coronal Image Processing (CORIMP)) to ensure the consistency of detections in each. Over the entire span of the LASCO catalogs, the automatic catalogs are well correlated with one another, to a level greater than 0.88. Focusing on just periods of higher activity, these correlations remain above 0.7. We establish the difficulty in comparing detections over the course of LASCO observations due to the change in the instrument image cadence in 2010. Without adjusting catalogs for the cadence, CME detection rates show a large spike in cycle 24, despite a notable drop in other indices of solar activity. The output from SEEDS, using a consistent image cadence, shows that the CME rate has not significantly changed relative to sunspot number in cycle 24. These data, and mass calculations from CORIMP, lead us to conclude that any apparent increase in CME rate is a result of the change in cadence. We study detection characteristics of CMEs, discussing potential physical changes in events between cycles 23 and 24. We establish that, for detected CMEs, physical parameters can also be sensitive to the cadence.

  17. Improving the ablation efficiency of excimer laser systems with higher repetition rates through enhanced debris removal and optimized spot pattern.

    Science.gov (United States)

    Arba-Mosquera, Samuel; Klinner, Thomas

    2014-03-01

    To evaluate the reasons for the required increased radiant exposure for higher-repetition-rate excimer lasers and determine experimentally possible compensations to achieve equivalent ablation profiles maintaining the same single-pulse energies and radiant exposures for laser repetition rates ranging from 430 to 1000 Hz. Schwind eye-tech-solutions GmbH and Co. KG, Kleinostheim, Germany. Experimental study. Poly(methyl methacrylate) (PMMA) plates were photoablated. The pulse laser energy was maintained during all experiments; the effects of the flow of the debris removal, the shot pattern for the correction, and precooling the PMMA plates were evaluated in terms of achieved ablation versus repetition rate. The mean ablation performance ranged from 88% to 100%; the variability between the profile measurements ranged from 1.4% to 6.2%. Increasing the laser repetition rate from 430 Hz to 1000 Hz reduced the mean ablation performance from 98% to 91% and worsened the variability from 1.9% to 4.3%. Increasing the flow of the debris removal, precooling the PMMA plates to -18°C, and adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the variability. Only adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the mean ablation performance. The ablation performance of higher-repetition-rate excimer lasers on PMMA improved with improvements in the debris removal systems and shot pattern. More powerful debris removal systems and smart shot patterns in terms of thermal response improved the performance of these excimer lasers. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. The Effects of Gun Ownership Rates and Gun Control Laws on Suicide Rates

    OpenAIRE

    Mark Gius

    2011-01-01

    The purpose of the present study is to determine the effects of gun control laws and gun ownership rates on state-level suicide rates. Using the most recent data on suicide rates, gun control measures, and gun ownership rates, the results of the present study suggest that states that require handgun permits have lower gun-related suicide rates, and states that have higher gun ownership rates have higher gun-related suicide rates. Regarding non-gun suicides, results suggest that stricter gun c...

  19. Electrochemical Detection with Preconcentration: Nitroenergetic Contaminants

    Directory of Open Access Journals (Sweden)

    Brandy J. Johnson

    2014-06-01

    Full Text Available This effort evaluated the potential of two prototype devices for enhanced electrochemical detection of 2,4,6-trinitrotoluene (TNT and dinitrotoluene (DNT following preconcentration using an organosilicate sorbent. The bench-scale prototype provides adsorption of the targets from aqueous solution followed by elution in a mixture of methanol and potassium chloride (KCl. Following elution, the eluant is diluted using an aqueous KCl solution to provide sufficient electrolyte for electrochemical analysis. Concentrations of methanol greater than 50% were detrimental to sensor performance and lifetime. Calibration of the electrochemical sensor was completed and results of electrochemical analysis were compared to those of HPLC analysis over a range of concentrations and in varied matrices. TNT detection was found to be consistent and detection limits were improved from 200 ppb to 3 ppb depending on the sample volume utilized. DNT detection showed higher variability and significantly greater false response rates. On the basis of these results, a second, more advanced, prototype was developed and utilized in limited field trials with the intention of moving the technology toward in situ applications.

  20. Detection of sentinel nodes with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Yokoyama, Kunihiko; Michigishi, Takatoshi; Kinuya, Seigo; Konishi, Shota; Nakajima, Kenichi; Tonami, Norihisa

    2000-01-01

    phytic acid, followed by albumin, and then tin colloid. Although the authors mainly use 99m Tc labeled phytic acid for carcinomas of the digestive system, there is a report suggesting a higher detection rate with 99m Tc labeled tin colloid. Thus, the rate of detection sentinel nodes of carcinoma of the digestive system with 99m Tc labeled phytic acid might be equivalent to the rate with of 99m Tc labeled tin colloid. It is therefore considered necessary to choose the most appropriate radiopharmaceutical for detection of sentinel lymph nodes according to the organ or tissue that is the site of the cancer. Although the detection rate by scintigraphy is lower in breast cancer than with the gamma probe, scintigraphy should also be performed in breast cancer, because useful information is obtained for surgery. Preoperative scintigraphy is indispensable in carcinoma of the digestive system because the gamma probe is difficult to use without the results of scintigraphy. Earlier detection of sentinel lymph nodes can be expected by combined use of a gamma probe and scintigraphy. (K.H.)

  1. Value of systematic intervention for chronic obstructive pulmonary disease in a regional Japanese city based on case detection rate and medical cost

    Directory of Open Access Journals (Sweden)

    Tawara Y

    2015-08-01

    Full Text Available Yuichi Tawara,1 Hideaki Senjyu,1 Kenichiro Tanaka,1 Takako Tanaka,1 Masaharu Asai,1 Ryo Kozu,2 Mitsuru Tabusadani,3 Sumihisa Honda,1 Terumitsu Sawai1 1Department of Cardiopulmonary Rehabilitation Science, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan; 2Department of Rehabilitation Medicine, Nagasaki University Hospital, Nagasaki, Japan; 3Center for Industry, University and Government Cooperation, Nagasaki University, Nagasaki, Japan Objective: We established a COPD taskforce for early detection, diagnosis, treatment, and intervention. We implemented a pilot intervention with a prospective and longitudinal design in a regional city. This study evaluates the usefulness of the COPD taskforce and intervention based on COPD case detection rate and per capita medical costs.Method: We distributed a questionnaire to all 8,878 inhabitants aged 50–89 years, resident in Matsuura, Nagasaki Prefecture in 2006. Potentially COPD-positive persons received a pulmonary function test and diagnosis. We implemented ongoing detection, examination, education, and treatment interventions, performed follow-up examinations or respiratory lessons yearly, and supported the health maintenance of each patient. We compared COPD medical costs in Matsuura and in the rest of Nagasaki Prefecture using data from 2004 to 2013 recorded by the association of Nagasaki National Health Insurance Organization, assessing 10-year means and annual change.Results: As of 2014, 256 people have received a definitive diagnosis of COPD; representing 31% of the estimated total number of COPD patients. Of the cases detected, 87.5% were mild or moderate in severity. COPD medical costs per patient in Matsuura were significantly lower than the rest of Nagasaki Prefecture, as was rate of increase in cost over time.Conclusion: The COPD program in Matsuura enabled early detection and treatment of COPD patients and helped to lower the associated burden of medical costs. The

  2. A study on a real-time leak detection method for pressurized liquid refrigerant pipeline based on pressure and flow rate

    International Nuclear Information System (INIS)

    Tian, Shen; Du, Juanli; Shao, Shuangquan; Xu, Hongbo; Tian, Changqing

    2016-01-01

    Highlights: • A real-time leak detection method is developed for ammonia pipeline in cold storage. • A locating algorithm based on pressure difference profile is provided. • This method is validated by R22 and ammonia leak experiments. • The minimum detectable leak ratio is 1% for R22 and 4% for ammonia. • The location estimating errors are −27% ~ 17% for R22 and −27% ~ 27% for ammonia. - Graphical Abstract: - Abstract: Leakage from pressurized liquid ammonia pipeline has been a serious problem in large commercial cold storages because it might release large amount of liquid ammonia and without safety supervision in daily operations. The present paper shows a detection method for a pressurized liquid ammonia pipeline with a leak. The variations of pressure, flow rate and pressure difference profile are studied. A leak indicator (σ), proposed with the one-dimensional steady-state flow model, is used to detect the leak occurrence by comparing it with a threshold value (σ Le ). A locating algorithm based on pressure difference profile along the pipeline is also proposed, which has considered the effect of the static pressure increase at the leak point. Experiments on different leak positions and ratios from liquid R22 and ammonia pipelines are carried out to validate this method. It is found that, with a relatively low false alarm rate (as three percent), the minimum detectable leak ratio reached 1% for the R22 pipeline and 4% for the ammonia pipeline. The locating errors are between −27% ~ 17% for R22 pipeline and −27% ~ 27% for ammonia pipeline.

  3. Fuzzy AutoEncode Based Cloud Detection for Remote Sensing Imagery

    Directory of Open Access Journals (Sweden)

    Zhenfeng Shao

    2017-03-01

    Full Text Available Cloud detection of remote sensing imagery is quite challenging due to the influence of complicated underlying surfaces and the variety of cloud types. Currently, most of the methods mainly rely on prior knowledge to extract features artificially for cloud detection. However, these features may not be able to accurately represent the cloud characteristics under complex environment. In this paper, we adopt an innovative model named Fuzzy Autoencode Model (FAEM to integrate the feature learning ability of stacked autoencode networks and the detection ability of fuzzy function for highly accurate cloud detection on remote sensing imagery. Our proposed method begins by selecting and fusing spectral, texture, and structure information. Thereafter, the proposed technique established a FAEM to learn the deep discriminative features from a great deal of selected information. Finally, the learned features are mapped to the corresponding cloud density map with a fuzzy function. To demonstrate the effectiveness of the proposed method, 172 Landsat ETM+ images and 25 GF-1 images with different spatial resolutions are used in this paper. For the convenience of accuracy assessment, ground truth data are manually outlined. Results show that the average RER (ratio of right rate and error rate on Landsat images is greater than 29, while the average RER of Support Vector Machine (SVM is 21.8 and Random Forest (RF is 23. The results on GF-1 images exhibit similar performance as Landsat images with the average RER of 25.9, which is much higher than the results of SVM and RF. Compared to traditional methods, our technique has attained higher average cloud detection accuracy for either different spatial resolutions or various land surfaces.

  4. Digitizing Tablet and Fahn–Tolosa–Marín Ratings of Archimedes Spirals have Comparable Minimum Detectable Change in Essential Tremor

    Directory of Open Access Journals (Sweden)

    Rodger J. Elble

    2017-07-01

    Full Text Available Background: Drawing Archimedes spirals is a popular and valid method of assessing action tremor in the upper limbs. We performed the first blinded comparison of Fahn–Tolosa–Marín (FTM ratings and tablet measures of essential tremor to determine if a digitizing tablet is better than 0–4 ratings in detecting changes in essential tremor that exceed random variability in tremor amplitude.Methods: The large and small spirals of FTM were drawn with each hand on two consecutive days by 14 men and four women (age 60±8.7 years [mean±SD] with mild to severe essential tremor. The drawings were simultaneously digitized with a digitizing tablet. Tremor in each digitized drawing was computed with spectral analysis in an independent laboratory, blinded to the clinical ratings. The mean peak-to-peak tremor displacement (cm in the four spirals and mean FTM ratings were compared statistically.Results: Test–retest intraclass correlations (ICCs (two-way random single measures, absolute agreement were excellent for the FTM ratings (ICC 0.90, 95% CI 0.76–0.96 and tablet (ICC 0.97, 95% CI 0.91–0.99. Log10 tremor amplitude (T and FTM were strongly correlated (logT = αFTM + β, α≈0.6, β≈–1.27, r = 0.94. The minimum detectable change for the tablet and FTM were 51% and 67% of the initial assessment.Discussion: Digitizing tablets are much more precise than clinical ratings, but this advantage is mitigated by the natural variability in tremor. Nevertheless, the digitizing tablet is a robust method of quantifying tremor that can be used in lieu of or in combination with clinical ratings.

  5. Detecting pits in tart cherries by hyperspectral transmission imaging

    Science.gov (United States)

    Qin, Jianwei; Lu, Renfu

    2004-11-01

    The presence of pits in processed cherry products causes safety concerns for consumers and imposes potential liability for the food industry. The objective of this research was to investigate a hyperspectral transmission imaging technique for detecting the pit in tart cherries. A hyperspectral imaging system was used to acquire transmission images from individual cherry fruit for four orientations before and after pits were removed over the spectral region between 450 nm and 1,000 nm. Cherries of three size groups (small, intermediate, and large), each with two color classes (light red and dark red) were used for determining the effect of fruit orientation, size, and color on the pit detection accuracy. Additional cherries were studied for the effect of defect (i.e., bruises) on the pit detection. Computer algorithms were developed using the neural network (NN) method to classify the cherries with and without the pit. Two types of data inputs, i.e., single spectra and selected regions of interest (ROIs), were compared. The spectral region between 690 nm and 850 nm was most appropriate for cherry pit detection. The NN with inputs of ROIs achieved higher pit detection rates ranging from 90.6% to 100%, with the average correct rate of 98.4%. Fruit orientation and color had a small effect (less than 1%) on pit detection. Fruit size and defect affected pit detection and their effect could be minimized by training the NN with properly selected cherry samples.

  6. Additional lesions detected in therapeutic scans with 177Lu-DOTATATE reflect higher affinity of 177Lu-DOTATATE for somatostatin receptors.

    Science.gov (United States)

    Mirzaei, Siroos; Bastati, Brigitte; Lipp, Rainer W; Knoll, Peter; Zojer, Niklas; Ludwig, Heinz

    2011-01-01

    Peptide receptor-targeted radionuclide therapy (PRRT) of somatostatin receptor (SR)-expressing neuroendocrine tumors (NETs) has become an established therapeutic option in patients with advanced NETs. The aim of this study was to compare the lesion detection rate of (99m)Tc-EDDA/HYNIC-TOC, a newly developed tracer for NET imaging, with (177)Lu-DOTATATE used for PRRT. 8 patients (4 women, 4 men, age range 46-76 years) with histologically proven NETs, who showed high SR loads by (99m)Tc-EDDA/HYNIC-TOC scintigraphy, were treated with (177)Lu-DOTATATE. After treatment, all patients were subjected to whole-body scintigraphy with additional low-dose single-photon emission computed tomography (SPECT-CT) of the chest and abdomen. All patients demonstrated (177)Lu-DOTATATE accumulation in all lesions previously detected by (99m)Tc- EDDA/HYNIC-TOC scintigraphy. Three patients showed additional lesions in the liver and lungs. SPECT-CT after (177)Lu-DOTATATE therapy may be helpful in detecting additional lesions not seen using (99m)Tc-EDDA/HYNIC-TOC. This could reflect the broader affinity of (177)Lu-DOTATATE for SRs compared with (99m)Tc-EDDA/HYNIC-TOC. Copyright © 2011 S. Karger AG, Basel.

  7. Higher speciation and lower extinction rates influence mammal diversity gradients in Asia.

    Science.gov (United States)

    Tamma, Krishnapriya; Ramakrishnan, Uma

    2015-02-04

    Little is known about the patterns and correlates of mammal diversity gradients in Asia. In this study, we examine patterns of species distributions and phylogenetic diversity in Asia and investigate if the observed diversity patterns are associated with differences in diversification rates between the tropical and non-tropical regions. We used species distribution maps and phylogenetic trees to generate species and phylogenetic diversity measures for 1° × 1° cells across mainland Asia. We constructed lineage-through-time plots and estimated diversification shift-times to examine the temporal patterns of diversifications across orders. Finally, we tested if the observed gradients in Asia could be associated with geographical differences in diversification rates across the tropical and non-tropical biomes. We estimated speciation, extinction and dispersal rates across these two regions for mammals, both globally and for Asian mammals. Our results demonstrate strong latitudinal and longitudinal gradients of species and phylogenetic diversity with Southeast Asia and the Himalayas showing highest diversity. Importantly, our results demonstrate that differences in diversification (speciation, extinction and dispersal) rates between the tropical and the non-tropical biomes influence the observed diversity gradients globally and in Asia. For the first time, we demonstrate that Asian tropics act as both cradles and museums of mammalian diversity. Temporal and spatial variation in diversification rates across different lineages of mammals is an important correlate of species diversity gradients observed in Asia.

  8. Higher tacrolimus trough levels on days 2-5 post-renal transplant are associated with reduced rates of acute rejection.

    LENUS (Irish Health Repository)

    O'Seaghdha, C M

    2011-04-06

    We analyzed the association between whole-blood trough tacrolimus (TAC) levels in the first days post-kidney transplant and acute cellular rejection (ACR) rates. Four hundred and sixty-four consecutive, deceased-donor kidney transplant recipients were included. All were treated with a combination of TAC, mycophenolate mofetil and prednisolone. Patients were analyzed in four groups based on quartiles of the mean TAC on days 2 and 5 post-transplant: Group 1: median TAC 11 ng\\/mL (n = 122, range 2-13.5 ng\\/mL), Group 2: median 17 ng\\/mL (n = 123, range 14-20 ng\\/mL), Group 3: median 24 ng\\/mL (n = 108, range 20.5-27 ng\\/mL) and Group 4: median 33.5 ng\\/mL (n = 116, range 27.5-77.5 ng\\/mL). A graded reduction in the rates of ACR was observed for each incremental days 2-5 TAC. The one-yr ACR rate was 24.03% (95% CI 17.26-32.88), 22.20% (95% CI 15.78-30.70), 13.41% (95% CI 8.15-21.63) and 8.69% (95% CI 4.77-15.55) for Groups 1-4, respectively (p = 0.003). This study suggests that higher early TACs are associated with reduced rates of ACR at one yr.

  9. Spectral anomaly methods for aerial detection using KUT nuisance rejection

    International Nuclear Information System (INIS)

    Detwiler, R.S.; Pfund, D.M.; Myjak, M.J.; Kulisek, J.A.; Seifert, C.E.

    2015-01-01

    This work discusses the application and optimization of a spectral anomaly method for the real-time detection of gamma radiation sources from an aerial helicopter platform. Aerial detection presents several key challenges over ground-based detection. For one, larger and more rapid background fluctuations are typical due to higher speeds, larger field of view, and geographically induced background changes. As well, the possible large altitude or stand-off distance variations cause significant steps in background count rate as well as spectral changes due to increased gamma-ray scatter with detection at higher altitudes. The work here details the adaptation and optimization of the PNNL-developed algorithm Nuisance-Rejecting Spectral Comparison Ratios for Anomaly Detection (NSCRAD), a spectral anomaly method previously developed for ground-based applications, for an aerial platform. The algorithm has been optimized for two multi-detector systems; a NaI(Tl)-detector-based system and a CsI detector array. The optimization here details the adaptation of the spectral windows for a particular set of target sources to aerial detection and the tailoring for the specific detectors. As well, the methodology and results for background rejection methods optimized for the aerial gamma-ray detection using Potassium, Uranium and Thorium (KUT) nuisance rejection are shown. Results indicate that use of a realistic KUT nuisance rejection may eliminate metric rises due to background magnitude and spectral steps encountered in aerial detection due to altitude changes and geographically induced steps such as at land–water interfaces

  10. Models for financial crisis detection in Indonesia based on bank deposits, real exchange rate and terms of trade indicators

    Science.gov (United States)

    Sugiyanto; Zukhronah, Etik; Nur Aini, Anis

    2017-12-01

    Several times Indonesia has experienced to face a financial crisis, but the crisis occurred in 1997 had a tremendous impact on the economy and national stability. The impact of the crisis fall the exchange rate of rupiah against the dollar so it is needed the financial crisis detection system. Some data of bank deposits, real exchange rate and terms of trade indicators are used in this paper. Data taken from January 1990 until December 2016 are used to form the models with three state. Combination of volatility and Markov switching models are used to model the data. The result suggests that the appropriate model for bank deposit and terms of trade is SWARCH (3,1), and for real exchange rates is SWARCH (3,2).

  11. Extended-Search, Bézier Curve-Based Lane Detection and Reconstruction System for an Intelligent Vehicle

    Directory of Open Access Journals (Sweden)

    Xiaoyun Huang

    2015-09-01

    Full Text Available To improve the real-time performance and detection rate of a Lane Detection and Reconstruction (LDR system, an extended-search-based lane detection method and a Bézier curve-based lane reconstruction algorithm are proposed in this paper. The extended-search-based lane detection method is designed to search boundary blocks from the initial position, in an upwards direction and along the lane, with small search areas including continuous search, discontinuous search and bending search in order to detect different lane boundaries. The Bézier curve-based lane reconstruction algorithm is employed to describe a wide range of lane boundary forms with comparatively simple expressions. In addition, two Bézier curves are adopted to reconstruct the lanes' outer boundaries with large curvature variation. The lane detection and reconstruction algorithm — including initial-blocks' determining, extended search, binarization processing and lane boundaries' fitting in different scenarios — is verified in road tests. The results show that this algorithm is robust against different shadows and illumination variations; the average processing time per frame is 13 ms. Significantly, it presents an 88.6% high-detection rate on curved lanes with large or variable curvatures, where the accident rate is higher than that of straight lanes.

  12. Does adding metformin to clomifene citrate lead to higher pregnancy rates in a subset of women with polycystic ovary syndrome?

    Science.gov (United States)

    Moll, E; Korevaar, J C; Bossuyt, P M M; van der Veen, F

    2008-08-01

    An RCT among newly diagnosed, therapy naive women with polycystic ovary syndrome (PCOS) showed no significant differences in ovulation rate, ongoing pregnancy rate or spontaneous abortion rate in favour of clomifene citrate plus metformin compared with clomifene citrate. We wanted to assess whether there are specific subgroups of women with PCOS in whom clomifene citrate plus metformin leads to higher pregnancy rates. Subgroup analysis based on clinical and biochemical parameters of 111 women randomized to clomifene citrate plus metformin compared with 114 women randomized to clomifene citrate plus placebo. The data for age, BMI, waist-hip ratio (WHR) and plasma testosterone were available in all women, 2 h glucose in 80% of women and homeostatic model assessment for assessing insulin sensitivity (HOMA) in 50% of women. Of the women who were allocated to the metformin group, 44 women (40%) reached an ongoing pregnancy. In the placebo group, 52 women (46%) reached an ongoing pregnancy. There was a significantly different chance of an ongoing pregnancy for metformin versus placebo between subgroups based on age and WHR (P = 0.014). There was a positive effect of metformin versus placebo on pregnancy rate in older women (>or=28 years) with a high WHR, a negative effect of metformin versus placebo in young women (Metformin may be an effective addition to clomifene citrate in infertile women with PCOS, especially in older and viscerally obese patients.

  13. High rates of detection of Clade 2.3.4.4 Highly Pathogenic Avian Influenza H5 viruses in wild birds in the Pacific Northwest during the winter of 2014-2015

    Science.gov (United States)

    Ip, Hon S.; Dusek, Robert J.; Bodenstein, Barbara L.; Kim Torchetti, Mia; DeBruyn, Paul; Mansfield, Kristin G.; DeLiberto, Thomas; Sleeman, Jonathan M.

    2016-01-01

    In 2014, Clade 2.3.4.4 H5N8 highly pathogenic avian influenza (HPAI) viruses spread across the Republic of Korea and ultimately were reported in China, Japan, Russia and Europe. Mortality associated with a reassortant HPAI H5N2 virus was detected in poultry farms in Western Canada at the end of November. The same strain (with identical genetic structure) was then detected in free-living wild birds that had died prior to December 8 of unrelated causes in Whatcom County, Washington, USA in an area contiguous with the index Canadian location. A gyrfalcon (Falco rusticolus) that had hunted and fed on an American wigeon (Anas americana) on December 6 in the same area and died two days later, tested positive for the Eurasian origin HPAI H5N8. Subsequently, an Active Surveillance Program using hunter-harvest waterfowl in Washington and Oregon detected ten HPAI H5 viruses, of three different subtypes (four H5N2, three H5N8 and three H5N1) with 4 segments in common (HA, PB2, NP and MA). In addition, a mortality-based Passive Surveillance Program detected 18 HPAI (14 H5N2 and four H5N8) cases from Idaho, Kansas, Oregon, Minnesota, Montana, Washington and Wisconsin. Comparatively, mortality-based passive surveillance appears to be detecting these HPAI infections at a higher rate than active surveillance during the period following initial introduction into the US.

  14. Improved detection rate of cytogenetic abnormalities in chronic lymphocytic leukemia and other mature B-cell neoplasms with use of CpG-oligonucleotide DSP30 and interleukin 2 stimulation.

    Science.gov (United States)

    Shi, Min; Cipollini, Matthew J; Crowley-Bish, Patricia A; Higgins, Anne W; Yu, Hongbo; Miron, Patricia M

    2013-05-01

    Detection of cytogenetic abnormalities requires successful culture of the clonal population to obtain metaphase chromosomes for study, and as such, has been hampered by low mitotic indices of mature B cells in culture. Our study presents data on the improved abnormality detection rate with the use of a CpG-oligonucleotide/interleukin 2 (OL/IL-2) culture protocol for mature B-cell neoplasms, including chronic lymphocytic leukemia (CLL) and non-CLL specimens. The increased detection rate of abnormalities, compared with unstimulated culture and traditional pokeweed mitogen culture, was statistically significant for both CLL and non-CLL neoplasms. For CLL specimens, our data also showed that for cytogenetically visible aberrations, OL/IL-2 was as, if not more, sensitive than detection with interphase fluorescence in situ hybridization (iFISH). Use of OL/IL-2 allowed a number of abnormalities to be detected, which were not covered by specific iFISH panels, especially balanced translocations. Therefore, OL/IL-2 stimulation improves diagnostic sensitivity and increases discovery rate of novel prognostic findings.

  15. Results of a pilot scale melter test to attain higher production rates

    International Nuclear Information System (INIS)

    Elliott, M.L.; Perez, J.M. Jr.; Chapman, C.C.

    1991-01-01

    A pilot-scale melter test was completed as part of the effort to enhance glass production rates. The experiment was designed to evaluate the effects of bulk glass temperature and feed oxide loading. The maximum glass production rate obtained, 86 kg/hr-m 2 , was over 200% better than the previous record for the melter used

  16. Online Adaboost-Based Parameterized Methods for Dynamic Distributed Network Intrusion Detection.

    Science.gov (United States)

    Hu, Weiming; Gao, Jun; Wang, Yanguo; Wu, Ou; Maybank, Stephen

    2014-01-01

    Current network intrusion detection systems lack adaptability to the frequently changing network environments. Furthermore, intrusion detection in the new distributed architectures is now a major requirement. In this paper, we propose two online Adaboost-based intrusion detection algorithms. In the first algorithm, a traditional online Adaboost process is used where decision stumps are used as weak classifiers. In the second algorithm, an improved online Adaboost process is proposed, and online Gaussian mixture models (GMMs) are used as weak classifiers. We further propose a distributed intrusion detection framework, in which a local parameterized detection model is constructed in each node using the online Adaboost algorithm. A global detection model is constructed in each node by combining the local parametric models using a small number of samples in the node. This combination is achieved using an algorithm based on particle swarm optimization (PSO) and support vector machines. The global model in each node is used to detect intrusions. Experimental results show that the improved online Adaboost process with GMMs obtains a higher detection rate and a lower false alarm rate than the traditional online Adaboost process that uses decision stumps. Both the algorithms outperform existing intrusion detection algorithms. It is also shown that our PSO, and SVM-based algorithm effectively combines the local detection models into the global model in each node; the global model in a node can handle the intrusion types that are found in other nodes, without sharing the samples of these intrusion types.

  17. Penguin head movement detected using small accelerometers: a proxy of prey encounter rate.

    Science.gov (United States)

    Kokubun, Nobuo; Kim, Jeong-Hoon; Shin, Hyoung-Chul; Naito, Yasuhiko; Takahashi, Akinori

    2011-11-15

    Determining temporal and spatial variation in feeding rates is essential for understanding the relationship between habitat features and the foraging behavior of top predators. In this study we examined the utility of head movement as a proxy of prey encounter rates in medium-sized Antarctic penguins, under the presumption that the birds should move their heads actively when they encounter and peck prey. A field study of free-ranging chinstrap and gentoo penguins was conducted at King George Island, Antarctica. Head movement was recorded using small accelerometers attached to the head, with simultaneous monitoring for prey encounter or body angle. The main prey was Antarctic krill (>99% in wet mass) for both species. Penguin head movement coincided with a slow change in body angle during dives. Active head movements were extracted using a high-pass filter (5 Hz acceleration signals) and the remaining acceleration peaks (higher than a threshold acceleration of 1.0 g) were counted. The timing of head movements coincided well with images of prey taken from the back-mounted cameras: head movement was recorded within ±2.5 s of a prey image on 89.1±16.1% (N=7 trips) of images. The number of head movements varied largely among dive bouts, suggesting large temporal variations in prey encounter rates. Our results show that head movement is an effective proxy of prey encounter, and we suggest that the method will be widely applicable for a variety of predators.

  18. A low-volume polyethylene glycol solution was associated with an increased suboptimal bowel preparation rate but had similar recommendations for an early repeat colonoscopy, procedure times, and adenoma detection rates.

    Directory of Open Access Journals (Sweden)

    Sam C Hankins

    Full Text Available Low-volume polyethylene glycol (PEG bowel preparations are better tolerated by patients than high-volume preparations and may achieve similar preparation quality. However, there is little data comparing their effects on a recommendation for an early repeat colonoscopy (because of a suboptimal preparation, procedure times, adenoma detection rate (ADR, and advanced adenoma detection rate (AADR.This is a retrospective cohort study of outpatient colonoscopies performed during a one-year period at a single academic medical center in which low-volume MoviPrep® (n = 1841 or high-volume Colyte® (n = 1337 was used. All preparations were split-dosed. Appropriate covariates were included in regression models assessing suboptimal preparation quality (fair, poor, or inadequate, procedure times, recommendation for an early repeat colonoscopy, ADR, and AADR.MoviPrep® was associated with an increase in having a suboptimal bowel preparation (OR 1.36; 95% CI: 1.06-1.76, but it was not associated with differences in insertion (p = 0.43, withdrawal (p = 0.22, or total procedure times (p = 0.10. The adjusted percentage with a suboptimal preparation was 11.7% for patients using MoviPrep® and 8.8% for patients using Colyte®. MoviPrep® was not associated with a significant difference in overall ADR (OR 0.93; 95% CI: 0.78-1.11, AADR (OR 1.18; 95% CI: 0.87-1.62, or recommendation for early repeat colonoscopy (OR 1.16; 95% CI: 0.72-1.88.MoviPrep® was associated with a small absolute increase in having a suboptimal preparation, but did not affect recommendations for an early repeat colonoscopy, procedure times, or adenoma detection rates. Mechanisms to reduce financial barriers limiting low-volume preparations should be considered because of their favorable tolerability profile.

  19. Implementing a Multiplexed System of Detectors for Higher Photon Counting Rates

    Science.gov (United States)

    2007-01-01

    Castelletto, I. P. Degiovanni, and M. L. Rastello, “Theoretical aspects of photon number measurement,” Metrologia , vol. 37, pp. 613-616, 2000. [19] http...source heralding efficiency and detection effi- ciency metrology at 1550 nm using periodically poled lithium niobate,” Metrologia , vol. 43, pp. S56-S60...2006. Valentina Schettini received her master degree in Physics at the University La Sapienza of Rome in 2003. In 2004 and 2005 she had a research

  20. International comparisons of preterm birth: higher rates of late preterm birth are associated with lower rates of stillbirth and neonatal death.

    Science.gov (United States)

    Lisonkova, S; Sabr, Y; Butler, B; Joseph, K S

    2012-12-01

    To examine international rates of preterm birth and potential associations with stillbirths and neonatal deaths at late preterm and term gestation. Ecological study. Canada, USA and 26 countries in Europe. All deliveries in 2004. Information on preterm birth (Statistics Canada, the EURO-PERISTAT project and the National Center for Health Statistics. Pearson correlation coefficients and random-intercept Poisson regression were used to examine the association between preterm birth rates and gestational age-specific stillbirth and neonatal death rates. Rate ratios with 95% confidence intervals were estimated after adjustment for maternal age, parity and multiple births. Stillbirths and neonatal deaths ≥ 32 and ≥ 37 weeks of gestation. International rates of preterm birth (births. Preterm birth rates at 32-36 weeks were inversely associated with stillbirths at ≥ 32 weeks (adjusted rate ratio 0.94, 95% CI 0.92-0.96) and ≥ 37 weeks (adjusted rate ratio 0.88, 95% CI 0.85-0.91) of gestation and inversely associated with neonatal deaths at ≥ 32 weeks (adjusted rate ratio 0.88, 95% CI 0.85-0.91) and ≥ 37 weeks (adjusted rate ratio 0.82, 95% CI 0.78-0.86) of gestation. Countries with high rates of preterm birth at 32-36 weeks of gestation have lower stillbirth and neonatal death rates at and beyond 32 weeks of gestation. Contemporary rates of preterm birth are indicators of both perinatal health and obstetric care services. © 2012 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2012 RCOG.

  1. Delay in diabetic retinopathy screening increases the rate of detection of referable diabetic retinopathy.

    Science.gov (United States)

    Scanlon, P H; Aldington, S J; Stratton, I M

    2014-04-01

    To assess whether there is a relationship between delay in retinopathy screening after diagnosis of type 2 diabetes and level of retinopathy detected. Patients were referred from 88 primary care practices to an English National Health Service diabetic eye screening programme. Data for screened patients were extracted from the primary care databases using semi-automated data collection algorithms supplemented by validation processes. The programme uses two-field mydriatic digital photographs graded by a quality assured team. Data were available for 8183 screened patients with diabetes newly diagnosed in 2005, 2006 or 2007. Only 163 with type 1 diabetes were identified and were insufficient for analysis. Data were available for 8020 with newly diagnosed type 2 diabetes. Of these, 3569 were screened within 6 months, 2361 between 6 and 11 months, 1058 between 12 and 17 months, 366 between 18 and 23 months, 428 between 24 and 35 months, and 238 at 3 years or more after diagnosis. There were 5416 (67.5%) graded with no retinopathy, 1629 (20.3%) with background retinopathy in one eye, 753 (9.4%) with background retinopathy in both eyes and 222 (2.8%) had referable diabetic retinopathy. There was a significant trend (P = 0.0004) relating time from diagnosis to screening detecting worsening retinopathy. Of those screened within 6 months of diagnosis, 2.3% had referable retinopathy and, 3 years or more after diagnosis, 4.2% had referable retinopathy. The rate of detection of referable diabetic retinopathy is elevated in those who were not screened promptly after diagnosis of type 2 diabetes. © 2013 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  2. The detection rate of [11C]Choline-PET/CT depends on the serum PSA-value in patients with biochemical recurrence of prostate cancer

    International Nuclear Information System (INIS)

    Krause, B.J.; Souvatzoglou, M.; Tuncel, M.; Herrmann, K.; Buck, A.K.; Praus, C.; Schwaiger, M.; Schuster, T.; Geinitz, H.; Treiber, U.

    2008-01-01

    An increase of the serum PSA-level is a sensitive in vitro marker for recurrent prostate cancer. However, it remains difficult to differentiate between local, regional or distant recurrent disease. The aim of this study was to assess the relationship between the detection rate of [ 11 C]Choline-PET/CT and the serum PSA-level in patients with a biochemical recurrence of prostate cancer with the view towards localisation of recurrent disease. Sixty-three patients (mean age, 68.8 ± 6.9; range, 45-83 years) with biochemical recurrence after primary therapy for prostate cancer were included in the analysis. Mean PSA-levels were 5.9 ± 9.7 ng/ml (range, 0.2-39 ng/ml; median, 2.15). Of the 63 patients, 17 were under anti-androgen therapy at the time of [ 11 C]Choline PET/CT. Patients underwent a [ 11 C]Choline-PET/CT study after injection of 656 ± 119 MBq [ 11 C]Choline on a Sensation 16 Biograph PET/CT scanner. Of the 63 patients, 35 (56%) showed a pathological [ 11 C]Choline uptake. The detection rate of [ 11 C]Choline-PET/CT showed a relationship with the serum PSA-level: The detection rate was 36% for a PSA-value 11 C]Choline-PET/CT (p = 0.374). As an important result our study shows that even for PSA-values 11 C]Choline-PET/CT is 36%. Furthermore, the detection rate of [ 11 C]Choline-PET/CT shows a positive relationship with serum PSA-levels in patients with biochemical recurrence of prostate cancer after primary therapy. Therefore, in these patients, [ 11 C]Choline PET/CT allows not only to diagnose but also to localise recurrent disease with implications on disease management (localised vs systemic therapy). (orig.)

  3. From b → sγ to the LSP detection rates in minimal string unification models

    International Nuclear Information System (INIS)

    Khalil, S.; Masiero, A.; Shafi, Q.

    1997-04-01

    We exploit the measured branching ratio for b → sγ to derive lower limits on the sparticle and Higgs masses in the minimal string unification models. For the LSP ('bino'), chargino and the lightest Higgs, these turn out to be 50, 90 and 75 GeV respectively. Taking account of the upper bounds on the mass spectrum from the LSP relic abundance, we estimate the direct detection rate for the latter to vary from 10 -1 to 10 -4 events/kg/day. The muon flux, produced by neutrinos from the annihilating LSP's, varies in the range 10 -2 - 10 -9 muons/m 2 /day. (author). 26 refs, 9 figs

  4. [Effect of high magnesium ion concentration on the electron transport rate and proton exchange in thylakoid membranes in higher plants].

    Science.gov (United States)

    Ignat'ev, A R; Khorobrykh, S A; Ivanov, B N

    2001-01-01

    The effects of magnesium ion concentration on the rate of electron transport in isolated pea thylakoids were investigated in the pH range from 4.0 up to 8.0. In the absence of magnesium ions in the medium and in the presence of 5 mM MgCl2 in the experiments not only without added artificial acceptors but also with ferricyanide or methylviologen as an acceptor, this rate had a well-expressed maximum at pH 5.0. It was shown that, after depression to minimal values at pH 5.5-6.5, it gradually rose with increasing pH. An increase in magnesium ion concentration up to 20 mM essentially affected the electron transfer rate: it decreased somewhat at pH 4.0-5.0 but increased at higher pH values. At this magnesium ion concentration, the maximum rate was at pH 6.0-6.5 and the minimum, at pH 7.0. Subsequent rise upon increasing pH to 8.0 was expressed more sharply. The influence of high magnesium ion concentration on the rate of electron transport was not observed in the presence of gramicidin D. It was found that without uncoupler, the changes in the electron transfer rate under the influence of magnesium ions correlated to the changes in the first-order rate constant of the proton efflux from thylakoids. It is supposed that the change in the ability of thylakoids to keep protons by the action of magnesium ions is the result of electrostatic interactions of these ions with the charges on the external surface of membranes. A possible role of regulation of the electron transport rate by magnesium ions in vivo is discussed.

  5. Hatching rate and growth rate of Nothobranchius guentheri fertilized eggs after space flight

    International Nuclear Information System (INIS)

    Guo Mingzhong; Zheng Leyun; Lin Guangji; Zhong Jianxing; Yang Huosheng; Zheng Yangfu

    2012-01-01

    Hatching, abnormal, growth and survival rate of the fertilized eggs of Nothobranchius guentheri were carried by Shenzhou 7 spacecraft were studied. The results indicated that the hatching and abnormal rate were no significant difference between the spaceflight group (99.3% and 16.8%) and ground group (97.2% and 10.4%); but the growth rate of male fish from spaceflight group was significant higher (0.094 g/d) than that of ground group (0.059 g/d), leading to the significant bigger of the male fish from spaceflight group. The survival rate of spaceflight group (66.7%) was higher than the ground group (47.9%). It was concluded that there was a higher growth and survival rate of Nothobranchius guentheri fertilized eggs after space flight. (authors)

  6. Detection rate of PET/CT in patients with biochemical relapse of prostate cancer using [{sup 68}Ga]PSMA I and T and comparison with published data of [{sup 68}Ga]PSMA HBED-CC

    Energy Technology Data Exchange (ETDEWEB)

    Berliner, Christoph; Tienken, Milena; Kobayashi, Yuske; Helberg, Annabelle; Kirchner, Uve; Klutmann, Susanne; Mester, Janos; Bannas, Peter [University Medical Center Hamburg-Eppendorf, Diagnostic and Interventional Radiology and Nuclear Medicine, Hamburg (Germany); Frenzel, Thorsten [University Medical Center Hamburg-Eppendorf, Ambulatory Center, Department for Radiation Oncology, Hamburg (Germany); Beyersdorff, Dirk [University Medical Center Hamburg-Eppendorf, Diagnostic and Interventional Radiology and Nuclear Medicine, Hamburg (Germany); University Medical Center Hamburg-Eppendorf, Martini-Klinik, Hamburg (Germany); Budaeus, Lars [University Medical Center Hamburg-Eppendorf, Martini-Klinik, Hamburg (Germany); Wester, Hans-Juergen [Technical University Munich, Pharmaceutical Radiochemistry, Garching (Germany)

    2017-04-15

    To determine the detection rate of PET/CT in biochemical relapse of prostate cancer using [{sup 68}Ga]PSMA I and T and to compare it with published detection rates of [{sup 68}Ga]PSMA HBED-CC. We performed a retrospective analysis in 83 consecutive patients with documented biochemical relapse after prostatectomy. All patients underwent whole body [{sup 68}Ga]PSMA I and T PET/CT. PET/CT images were evaluated for presence of local recurrence, lymph node metastases, and distant metastases. Proportions of positive PET/CT results were calculated for six subgroups with increasing prostate specific antigen (PSA) levels (<0.5 ng/mL, 0.5 to <1.0 ng/mL, 1.0 to <2.0 ng/mL, 2.0 to <5.0 ng/mL, 5.0 to <10.0, ≥10.0 ng/mL). Detection rates of [{sup 68}Ga]PSMA I and T were statistically compared with published detection rates of [{sup 68}Ga]PSMA HBED-CC using exact Fisher's test. Median PSA was 0.81 (range: 0.01 - 128) ng/mL. In 58/83 patients (70 %) at least one [{sup 68}Ga]PSMA I and T positive lesion was detected. Local recurrent cancer was present in 18 patients (22 %), lymph node metastases in 29 patients (35 %), and distant metastases in 15 patients (18 %). The tumor detection rate was positively correlated with PSA levels, resulting in detection rates of 52 % (<0.5 ng/mL), 55 % (0.5 to <1.0 ng/mL), 70 % (1.0 to <2.0 ng/mL), 93 % (2.0 to <5.0 ng/mL), 100 % (5.0 to <10.0 ng/mL), and 100 % (≥10.0 ng/mL). There was no significant difference between the detection rate of [{sup 68}Ga]PSMA I and T and published detection rates of [{sup 68}Ga]PSMA HBED-CC (all p>0.05). [{sup 68}Ga]PSMA I and T PET/CT has high detection rates of recurrent prostate cancer that are comparable to [{sup 68}Ga]PSMA HBED-CC. (orig.)

  7. Investigating Strength and Frequency Effects in Recognition Memory Using Type-2 Signal Detection Theory

    Science.gov (United States)

    Higham, Philip A.; Perfect, Timothy J.; Bruno, Davide

    2009-01-01

    Criterion- versus distribution-shift accounts of frequency and strength effects in recognition memory were investigated with Type-2 signal detection receiver operating characteristic (ROC) analysis, which provides a measure of metacognitive monitoring. Experiment 1 demonstrated a frequency-based mirror effect, with a higher hit rate and lower…

  8. Clinical significance of detection of GAD-Ab, ICA and IAA in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Zhou Jinhong; Liu Zhenzong; Wang Huimin

    2006-01-01

    To explore value of combined detection of glutamic acid decarboxylase antibody(GAD-Ab), islet cell antibody (ICA) and insulin autoantibody (IAA) in patients with diabetes mellitus (DM). Serum GAD-Ab, ICA and IAA were detected by chemiluminescent immunoassay and RIA in 46 of type 1 diabetes mellitus (1 DM), 78 of 2 DM respectively, and in 50 nondiabetic subjects as control group, and analysed according to the positive rates of different groups. Results showed that the positive rate of GAD-Ab was 67.39%, ICA 39.73%, IAA 23.91% in 1 DM,and that of GAD-Ab was 8.97%, ICA 15.39%, IAA 10.26% in 2 DM respectively. The positive rate of combined detection of GAD-Ab, ICA and IAA was 91.30% in patients with 1 DM, and 29.49% which was higher than that in control group (P<0.01). The detection of serum GAD-Ab,ICA and IAA might be regarded as clinical significance for classification, treatment and predict prognosis of DM. (authors)

  9. Reproductive traits of Holsteins and Jerseys. Effects of age, milk yield, and clinical abnormalities on involution of cervix and uterus, ovulation, estrous cycles, detection of estrus, conception rate, and days open.

    Science.gov (United States)

    Fonseca, F A; Britt, J H; McDaniel, B T; Wilk, J C; Rakes, A H

    1983-05-01

    Two hundred and twelve Holstein and Jersey cows were in a study to determine factors that affected reproductive traits. First ovulation occurred about 3 wk postpartum, and interval to first ovulation was greater in cows that had clinical abnormalities postpartum than in normal cows. Jerseys producing more milk ovulated sooner postpartum than lower producing herdmates. Involution of cervix and uterus occurred later postpartum in cows that had clinical problems postpartum. Involution of genital tract occurred later postpartum in older cows and sooner postpartum in cows that had higher milk yields. Duration of first postpartum estrous cycle was 4 days less than for second postpartum cycle. Percentages of estrous cycles detected by standing estrus were 43 and 73% for Holsteins and Jerseys. Estrous detection rates were highest for cows that produced slightly above the mean milk yield and did not differ between cows in highest and lowest milk production quartiles. First detected estrus and days to first insemination occurred later postpartum in Holsteins as milk yield deviation from herdmates increased, regardless of sign. In Jerseys, days to first insemination and days open increased linearly as milk yield increased. Days to first insemination and conception were greater in cows with postpartum clinical problems. Conception rate at first insemination postpartum increased in proportion to concentration of progesterone in blood samples collected during 12 days before first insemination. Overall, clinical problems at parturition and postpartum lowered reproductive performance in both breeds. There was a slight antagonism between milk yield and reproductive performance (days open) in Jerseys but not in Holsteins.

  10. Higher Education, Poverty and Development

    Science.gov (United States)

    Tilak, Jandhyala B. G.

    2010-01-01

    There is a presumption among many policy makers that higher education is not necessary for economic growth and development; it is literacy and basic education and at best secondary education that are argued to be important. Estimates of internal rate of return contributed to strengthening of such a presumption. Accordingly, higher education has…

  11. High-Rate Data-Capture for an Airborne Lidar System

    Science.gov (United States)

    Valett, Susan; Hicks, Edward; Dabney, Philip; Harding, David

    2012-01-01

    A high-rate data system was required to capture the data for an airborne lidar system. A data system was developed that achieved up to 22 million (64-bit) events per second sustained data rate (1408 million bits per second), as well as short bursts (less than 4 s) at higher rates. All hardware used for the system was off the shelf, but carefully selected to achieve these rates. The system was used to capture laser fire, single-photon detection, and GPS data for the Slope Imaging Multi-polarization Photo-counting Lidar (SIMPL). However, the system has applications for other laser altimeter systems (waveform-recording), mass spectroscopy, xray radiometry imaging, high-background- rate ranging lidar, and other similar areas where very high-speed data capture is needed. The data capture software was used for the SIMPL instrument that employs a micropulse, single-photon ranging measurement approach and has 16 data channels. The detected single photons are from two sources those reflected from the target and solar background photons. The instrument is non-gated, so background photons are acquired for a range window of 13 km and can comprise many times the number of target photons. The highest background rate occurs when the atmosphere is clear, the Sun is high, and the target is a highly reflective surface such as snow. Under these conditions, the total data rate for the 16 channels combined is expected to be approximately 22 million events per second. For each photon detection event, the data capture software reads the relative time of receipt, with respect to a one-per-second absolute time pulse from a GPS receiver, from an event timer card with 0.1-ns precision, and records that information to a RAID (Redundant Array of Independent Disks) storage device. The relative time of laser pulse firings must also be read and recorded with the same precision. Each of the four event timer cards handles the throughput from four of the channels. For each detection event, a flag is

  12. The relationship between socio-economic status and cancer detection at screening

    Science.gov (United States)

    Taylor-Phillips, Sian; Ogboye, Toyin; Hamborg, Tom; Kearins, Olive; O'Sullivan, Emma; Clarke, Aileen

    2015-03-01

    It is well known that socio-economic status is a strong predictor of screening attendance, with women of higher socioeconomic status more likely to attend breast cancer screening. We investigated whether socio-economic status was related to the detection of cancer at breast screening centres. In two separate projects we combined UK data from the population census, the screening information systems, and the cancer registry. Five years of data from all 81 screening centres in the UK was collected. Only women who had previously attended screening were included. The study was given ethical approval by the University of Warwick Biomedical Research Ethics committee reference SDR-232-07- 2012. Generalised linear models with a log-normal link function were fitted to investigate the relationship between predictors and the age corrected cancer detection rate at each centre. We found that screening centres serving areas with lower average socio-economic status had lower cancer detection rates, even after correcting for the age distribution of the population. This may be because there may be a correlation between higher socio-economic status and some risk factors for breast cancer such as nullparity (never bearing children). When applying adjustment for age, ethnicity and socioeconomic status of the population screened (rather than simply age) we found that SDR can change by up to 0.11.

  13. The Offer of Advanced Imaging Techniques Leads to Higher Acceptance Rates for Screening Colonoscopy - a Prospective Study.

    Science.gov (United States)

    Albrecht, Heinz; Gallitz, Julia; Hable, Robert; Vieth, Michael; Tontini, Gian Eugenio; Neurath, Markus Friedrich; Riemann, Jurgen Ferdinand; Neumann, Helmut

    2016-01-01

    Colonoscopy plays a fundamental role in early diagnosis and management of colorectal cancer and requires public and professional acceptance to ensure the ongoing success of screening programs. The aim of the study was to prospectively assess whether patient acceptance rates to undergo screening colonoscopy could be improved by the offer of advanced imaging techniques. Overall, 372 randomly selected patients were prospectively included. A standardized questionnaire was developed that inquired of the patients their knowledge regarding advanced imaging techniques. Second, several media campaigns and information events were organized reporting about advanced imaging techniques, followed by repeated evaluation. After one year the evaluation ended. At baseline, 64% of the patients declared that they had no knowledge about new endoscopic methods. After twelve months the overall grade of information increased significantly from 14% at baseline to 34%. The percentage of patients who decided to undergo colonoscopy because of the offer of new imaging methods also increased significantly from 12% at baseline to 42% after 12 months. Patients were highly interested in the offer of advanced imaging techniques. Knowledge about these techniques could relatively easy be provided using local media campaigns. The offer of advanced imaging techniques leads to higher acceptance rates for screening colonoscopies.

  14. Detection Range of Airborne Magnetometers in Magnetic Anomaly Detection

    Directory of Open Access Journals (Sweden)

    Chengjing Li

    2015-11-01

    Full Text Available Airborne magnetometers are utilized for the small-range search, precise positioning, and identification of the ferromagnetic properties of underwater targets. As an important performance parameter of sensors, the detection range of airborne magnetometers is commonly set as a fixed value in references regardless of the influences of environment noise, target magnetic properties, and platform features in a classical model to detect airborne magnetic anomalies. As a consequence, deviation in detection ability analysis is observed. In this study, a novel detection range model is proposed on the basis of classic detection range models of airborne magnetometers. In this model, probability distribution is applied, and the magnetic properties of targets and the environment noise properties of a moving submarine are considered. The detection range model is also constructed by considering the distribution of the moving submarine during detection. A cell-averaging greatest-of-constant false alarm rate test method is also used to calculate the detection range of the model at a desired false alarm rate. The detection range model is then used to establish typical submarine search probabilistic models. Results show that the model can be used to evaluate not only the effects of ambient magnetic noise but also the moving and geomagnetic features of the target and airborne detection platform. The model can also be utilized to display the actual operating range of sensor systems.

  15. Objective measures for detecting the auditory brainstem response: comparisons of specificity, sensitivity and detection time

    DEFF Research Database (Denmark)

    Chesnaye, M. A.; Bell, S. L.; Harte, J. M.

    2018-01-01

    of the Hotelling's T-2 test (applied in either time or frequency domain), two versions of the modified q-sample uniform scores test and both the Fsp and Fmp, which were evaluated using both conventional F-distributions with assumed degrees of freedom and a bootstrap approach. Study sample: Data consisted of click......-level when evaluating statistical significance using the bootstrap approach, as opposed to using conventional F-distributions. The FPRs of the remaining methods were slightly higher than expected. Conclusions: In this work, Hotelling's T-2 outperformed the alternative methods for automatically detecting ABRs......-evoked ABRs and recordings of EEG background activity from 12 to 17 normal hearing adults, respectively. Results: An overall advantage in sensitivity and detection time was demonstrated for the Hotelling's T-2 test. The false-positive rates (FPRs) of the Fsp and Fmp were also closer to the nominal alpha...

  16. Carbon Dioxide Insufflation Increases Colonoscopic Adenoma Detection Rate Compared With Air Insufflation.

    Science.gov (United States)

    Mills, Christopher D; McCamley, Chere; Swan, Michael P

    2018-03-07

    To determine the effect of carbon dioxide insufflation on the most important outcome measure of colonoscopic quality: adenoma detection rate (ADR). Bowel cancer is the second most common cause of cancer deaths in males and females in Australia. Carbon dioxide has in recent times become the insufflation methodology of choice for screening colonoscopy for bowel cancer, as this has been shown to have significant advantages when compared with traditional air insufflation. Endoscopies performed over a period of 9 months immediately before and after the implementation of carbon dioxide insufflation at endoscopy centers were eligible for inclusion. The difference in ADR between the carbon dioxide and air insufflation methods was statistically significant, with an increased ADR in the carbon dioxide group. The superiority of carbon dioxide insufflation was sustained with a logistic regression model, which showed ADR was significantly impacted by insufflation method. Carbon dioxide insufflation is known to reduce abdominal pain, postprocedural duration of abdominal pain, abdominal distension, and analgesic requirements. This study represents for the first time the beneficial effect of carbon dioxide insufflation upon the key quality colonoscopy indicator of ADR.

  17. The ability of NT-proBNP to detect chronic heart failure and predict all-cause mortality is higher in elderly Chinese coronary artery disease patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Fu S

    2013-04-01

    Full Text Available Shihui Fu, Leiming Luo, Ping Ye, Shuangyan Yi, Yuan Liu, Bing Zhu, Liang Wang, Tiehui Xiao, Yongyi Bai Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People's Republic of China Objective: To analyze the relationship between N-terminal pro-brain natriuretic peptide (NT-proBNP and renal function, and compare the ability and cut-off thresholds of NT-proBNP to detect chronic heart failure (CHF and predict mortality in elderly Chinese coronary artery disease (CAD patients with and without chronic kidney disease (CKD. Methods: The study included 999 CAD patients older than 60 years. The endpoint was all-cause mortality over a mean follow-up period of 417 days. Results: The median age was 86 years (range: 60–104 years, and the median NT-proBNP level was 409.8 pg/mL. CKD was present in 358 patients. Three hundred and six patients were positive for CHF. One hundred and ten CKD patients and 105 non-CKD patients died. Not only CKD, but also estimated glomerular filtration rate independently affected NT-proBNP. NT-proBNP detected CHF with a cut-off value of 298.4 pg/mL in non-CKD patients and a cut-off value of 435.7 pg/mL in CKD patients. NT-proBNP predicted death with a cut-off value of 369.5 pg/mL in non-CKD patients and a cut-off value of 2584.1 pg/mL in CKD patients. The NT-proBNP level was significantly related to the prevalence of CHF and all-cause mortality in CAD patients with and without CKD; this effect persisted after adjustment. The crude and multiple adjusted hazard ratios of NT-proBNP to detect CHF and predict mortality were significantly higher in patients with CKD compared with the remainder of the population. The addition of NT-proBNP to the three-variable and six-variable models generated a significant increase in the C-statistic. Conclusion: Amongst elderly Chinese CAD patients, there was an independently inverse association between NT-proBNP and renal function. With the higher cutoff points, NT

  18. Reducing Error Rates for Iris Image using higher Contrast in Normalization process

    Science.gov (United States)

    Aminu Ghali, Abdulrahman; Jamel, Sapiee; Abubakar Pindar, Zahraddeen; Hasssan Disina, Abdulkadir; Mat Daris, Mustafa

    2017-08-01

    Iris recognition system is the most secured, and faster means of identification and authentication. However, iris recognition system suffers a setback from blurring, low contrast and illumination due to low quality image which compromises the accuracy of the system. The acceptance or rejection rates of verified user depend solely on the quality of the image. In many cases, iris recognition system with low image contrast could falsely accept or reject user. Therefore this paper adopts Histogram Equalization Technique to address the problem of False Rejection Rate (FRR) and False Acceptance Rate (FAR) by enhancing the contrast of the iris image. A histogram equalization technique enhances the image quality and neutralizes the low contrast of the image at normalization stage. The experimental result shows that Histogram Equalization Technique has reduced FRR and FAR compared to the existing techniques.

  19. How to Pay for Higher Education.

    Science.gov (United States)

    Killingsworth, Charles C.

    The financial crisis for institutions of higher education is deepening. Higher tuition rates may be one of the answers, but this would exclude even more young people from attending college because of inability to pay, at a time when greater equality of opportunity in higher education has become an important goal. Federal support has helped but not…

  20. Next-generation narrow band imaging system for colonic polyp detection: a prospective multicenter randomized trial.

    Science.gov (United States)

    Horimatsu, Takahiro; Sano, Yasushi; Tanaka, Shinji; Kawamura, Takuji; Saito, Shoichi; Iwatate, Mineo; Oka, Shiro; Uno, Koji; Yoshimura, Kenichi; Ishikawa, Hideki; Muto, Manabu; Tajiri, Hisao

    2015-07-01

    Previous studies have yielded conflicting results on the colonic polyp detection rate with narrow-band imaging (NBI) compared with white-light imaging (WLI). We compared the mean number of colonic polyps detected per patient for NBI versus WLI using a next-generation NBI system (EVIS LUCERA ELITE; Olympus Medical Systems) used with standard-definition (SD) colonoscopy and wide-angle (WA) colonoscopy. this study is a 2 × 2 factorial, prospective, multicenter randomized controlled trial. this study was conducted at five academic centers in Japan. patients were allocated to one of four groups: (1) WLI with SD colonoscopy (H260AZI), (2) NBI with SD colonoscopy (H260AZI), (3) WLI with WA colonoscopy (CF-HQ290), and (4) NBI with WA colonoscopy (CF-HQ290). the mean numbers of polyps detected per patient were compared between the four groups: WLI with/without WA colonoscopy and NBI with/without WA colonoscopy. Of the 454 patients recruited, 431 patients were enrolled. The total numbers of polyps detected by WLI with SD, NBI with SD, WLI with WA, and NBI with WA were 164, 176, 188, and 241, respectively. The mean number of polyps detected per patient was significantly higher in the NBI group than in the WLI group (2.01 vs 1.56; P = 0.032). The rate was not higher in the WA group than in the SD group (1.97 vs 1.61; P = 0.089). Although WA colonoscopy did not improve the polyp detection, next-generation NBI colonoscopy represents a significant improvement in the detection of colonic polyps.

  1. Optimizing rate of nitrogen application for higher growth and yield of wheat (triticum aestivum l.) cultivars

    International Nuclear Information System (INIS)

    Maqsood, M.; Shehzad, M.A.; Asim, A.; Ahmad, W.

    2012-01-01

    In order to optimize the nitrogen rates in three wheat (Triticum aestivum L.) cultivars for obtaining higher grain yield, a split plot experiment based on Randomized Complete Block Design with three replicates was conducted in the research field of University of Agriculture, Faisalabad during Rabi season 2006-07. Among treatments nitrogen levels (N0= 0, N/sub 1/= 50, N2= 100, N3= 150 kg ha/sup -1/) in main while wheat cultivars (V1= Punjnad-I, V/sub 2/= Fareed-2006, V3=Uqab-2000) were allocated in sub plots during the course of growing season. Traits as plant height, fertile tillers, spike length, spikelets spike-1, grains spike-1, 1000-grain weight, straw yield, grain yield and harvest index (HI) were significantly (P=0.05) affected by treatment combinations. Maximum grain yield was obtained by V3 (Uqab-2000) cultivar when treated with N3 (150 kg ha/sup -1/) fertilizer level. Also, results showed that with increasing nitrogen rates, wheat yield increases significantly up to a level of significance (P=0.05). Increasing nitrogen levels led to significantly increase in plant height (101.81 cm), spike bearing tillers (495.77), grains spike/sup -1/ (61.45), straw yield (8.60 t ha/sup -1/) and harvest index (36.17%) of V3 (Uqab-2000). In all traits except germination count, V3 (Uqab-2000) was found to be superior. (author)

  2. Detecting subarachnoid hemorrhage: Comparison of combined FLAIR/SWI versus CT

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Rajeev Kumar, E-mail: rajeev.verma@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Kottke, Raimund, E-mail: raimund.kottke@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Andereggen, Lukas, E-mail: lukas.andereggen@insel.ch [Department of Neurosurgery, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Weisstanner, Christian, E-mail: christian.weisstanner@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Zubler, Christoph, E-mail: christoph.zubler@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Gralla, Jan, E-mail: jan.gralla@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Kiefer, Claus, E-mail: claus.kiefer@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Slotboom, Johannes, E-mail: johannes.slotboom@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); and others

    2013-09-15

    Objectives: Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. Methods: Twenty-five patients with acute SAH underwent CT and MRI within 6 days after symptom onset. Underlying pathology for SAH was head trauma (n = 9), ruptured aneurysm (n = 6), ruptured arteriovenous malformation (n = 2), and spontaneous bleeding (n = 8). SWI, FLAIR, and CT data were analyzed. The anatomical distribution of SAH was subdivided into 8 subarachnoid regions with three peripheral cisterns (frontal-parietal, temporal-occipital, sylvian), two central cisterns and spaces (interhemispheric, intraventricular), and the perimesencephalic, posterior fossa, superior cerebellar cisterns. Results: SAH was detected in a total of 146 subarachnoid regions. CT identified 110 (75.3%), FLAIR 127 (87%), and SWI 129 (88.4%) involved regions. Combined FLAIR and SWI identified all 146 detectable regions (100%). FLAIR was sensitive for frontal-parietal, temporal-occipital and Sylvian cistern SAH, while SWI was particularly sensitive for interhemispheric and intraventricular hemorrhage. Conclusions: By combining SWI and FLAIR, MRI yields a distinctly higher detection rate for SAH than CT alone, particularly due to their complementary detection characteristics in different anatomical regions. Detection strength of SWI is high in central areas, whereas FLAIR shows a better detection rate in peripheral areas.

  3. Authors attain comparable or slightly higher rates of citation publishing in an open access journal (CytoJournal compared to traditional cytopathology journals - A five year (2007-2011 experience

    Directory of Open Access Journals (Sweden)

    Nora K Frisch

    2014-01-01

    Full Text Available Background: The era of Open Access (OA publication, a platform which serves to better disseminate scientific knowledge, is upon us, as more OA journals are in existence than ever before. The idea that peer-reviewed OA publication leads to higher rates of citation has been put forth and shown to be true in several publications. This is a significant benefit to authors and is in addition to another relatively less obvious but highly critical component of the OA charter, i.e. retention of the copyright by the authors in the public domain. In this study, we analyzed the citation rates of OA and traditional non-OA publications specifically for authors in the field of cytopathology. Design: We compared the citation patterns for authors who had published in both OA and traditional non-OA peer-reviewed, scientific, cytopathology journals. Citations in an OA publication (CytoJournal were analyzed comparatively with traditional non-OA cytopathology journals (Acta Cytologica, Cancer Cytopathology, Cytopathology, and Diagnostic Cytopathology using the data from web of science citation analysis site (based on which the impact factors (IF are calculated. After comparing citations per publication, as well as a time adjusted citation quotient (which takes into account the time since publication, we also analyzed the statistics after excluding the data for meeting abstracts. Results: Total 28 authors published 314 publications as articles and meeting abstracts (25 authors after excluding the abstracts. The rate of citation and time adjusted citation quotient were higher for OA in the group where abstracts were included (P < 0.05 for both. The rates were also slightly higher for OA than non-OA when the meeting abstracts were excluded, but the difference was statistically insignificant (P = 0.57 and P = 0.45. Conclusion : We observed that for the same author, the publications in the OA journal attained a higher rate of citation than the publications in the

  4. Does basal metabolic rate drive eating rate?

    Science.gov (United States)

    Henry, Christiani Jeyakumar; Ponnalagu, Shalini; Bi, Xinyan; Forde, Ciaran

    2018-05-15

    There have been recent advances in our understanding of the drivers of energy intake (EI). However, the biological drivers of differences in eating rate (ER) remain less clear. Studies have reported that the fat-free mass (FFM) and basal metabolic rate (BMR) are both major components that contribute to daily energy expenditure (EE) and drive EI. More recently, a number of observations report that higher ER can lead to greater EI. The current study proposed that adults with a higher BMR and higher energy requirements would also exhibit higher ERs. Data on BMR, FFM, and ER were collected from 272 Chinese adults (91 males and 181 females) in a cross-sectional study. Analysis showed significant positive associations between BMR and ER (r s  = 0.405, p BMR explained about 15% of the variation in ER which was taken to be metabolically significant. This association provides metabolic explanation that the differences in an individual's BMR (hence energy requirements) may be correlated with ERs. This merits further research. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Using the Dual-Tree Complex Wavelet Transform for Improved Fabric Defect Detection

    Directory of Open Access Journals (Sweden)

    Hermanus Vermaak

    2016-01-01

    Full Text Available The dual-tree complex wavelet transform (DTCWT solves the problems of shift variance and low directional selectivity in two and higher dimensions found with the commonly used discrete wavelet transform (DWT. It has been proposed for applications such as texture classification and content-based image retrieval. In this paper, the performance of the dual-tree complex wavelet transform for fabric defect detection is evaluated. As experimental samples, the fabric images from TILDA, a textile texture database from the Workgroup on Texture Analysis of the German Research Council (DFG, are used. The mean energies of real and imaginary parts of complex wavelet coefficients taken separately are identified as effective features for the purpose of fabric defect detection. Then it is shown that the use of the dual-tree complex wavelet transform yields greater performance as compared to the undecimated wavelet transform (UDWT with a detection rate of 4.5% to 15.8% higher depending on the fabric type.

  6. A Vision-Based Approach to Fire Detection

    Directory of Open Access Journals (Sweden)

    Pedro Gomes

    2014-09-01

    Full Text Available This paper presents a vision-based method for fire detection from fixed surveillance smart cameras. The method integrates several well-known techniques properly adapted to cope with the challenges related to the actual deployment of the vision system. Concretely, background subtraction is performed with a context-based learning mechanism so as to attain higher accuracy and robustness. The computational cost of a frequency analysis of potential fire regions is reduced by means of focusing its operation with an attentive mechanism. For fast discrimination between fire regions and fire-coloured moving objects, a new colour-based model of fire's appearance and a new wavelet-based model of fire's frequency signature are proposed. To reduce the false alarm rate due to the presence of fire-coloured moving objects, the category and behaviour of each moving object is taken into account in the decision-making. To estimate the expected object's size in the image plane and to generate geo-referenced alarms, the camera-world mapping is approximated with a GPS-based calibration process. Experimental results demonstrate the ability of the proposed method to detect fires with an average success rate of 93.1% at a processing rate of 10 Hz, which is often sufficient for real-life applications.

  7. Prospective comparison of the detection rates of human enterovirus and parechovirus RT-qPCR and viral culture in different pediatric specimens

    NARCIS (Netherlands)

    de Crom, S C M; Obihara, C C; de Moor, R A; Veldkamp, E J M; van Furth, A M; Rossen, J W A

    2013-01-01

    BACKGROUND: Reverse-transcriptase quantitative real-time polymerase chain reaction (RT-qPCR) has become the gold standard for the diagnosis of human enterovirus (EV) and parechovirus (HPeV) infections. The detection rate of RT-qPCR in different pediatric body specimens has not been compared

  8. Accounting for detectability in fish distribution models: an approach based on time-to-first-detection

    Directory of Open Access Journals (Sweden)

    Mário Ferreira

    2015-12-01

    Full Text Available Imperfect detection (i.e., failure to detect a species when the species is present is increasingly recognized as an important source of uncertainty and bias in species distribution modeling. Although methods have been developed to solve this problem by explicitly incorporating variation in detectability in the modeling procedure, their use in freshwater systems remains limited. This is probably because most methods imply repeated sampling (≥ 2 of each location within a short time frame, which may be impractical or too expensive in most studies. Here we explore a novel approach to control for detectability based on the time-to-first-detection, which requires only a single sampling occasion and so may find more general applicability in freshwaters. The approach uses a Bayesian framework to combine conventional occupancy modeling with techniques borrowed from parametric survival analysis, jointly modeling factors affecting the probability of occupancy and the time required to detect a species. To illustrate the method, we modeled large scale factors (elevation, stream order and precipitation affecting the distribution of six fish species in a catchment located in north-eastern Portugal, while accounting for factors potentially affecting detectability at sampling points (stream depth and width. Species detectability was most influenced by depth and to lesser extent by stream width and tended to increase over time for most species. Occupancy was consistently affected by stream order, elevation and annual precipitation. These species presented a widespread distribution with higher uncertainty in tributaries and upper stream reaches. This approach can be used to estimate sampling efficiency and provide a practical framework to incorporate variations in the detection rate in fish distribution models.

  9. A DDoS Attack Detection Method Based on Hybrid Heterogeneous Multiclassifier Ensemble Learning

    Directory of Open Access Journals (Sweden)

    Bin Jia

    2017-01-01

    Full Text Available The explosive growth of network traffic and its multitype on Internet have brought new and severe challenges to DDoS attack detection. To get the higher True Negative Rate (TNR, accuracy, and precision and to guarantee the robustness, stability, and universality of detection system, in this paper, we propose a DDoS attack detection method based on hybrid heterogeneous multiclassifier ensemble learning and design a heuristic detection algorithm based on Singular Value Decomposition (SVD to construct our detection system. Experimental results show that our detection method is excellent in TNR, accuracy, and precision. Therefore, our algorithm has good detective performance for DDoS attack. Through the comparisons with Random Forest, k-Nearest Neighbor (k-NN, and Bagging comprising the component classifiers when the three algorithms are used alone by SVD and by un-SVD, it is shown that our model is superior to the state-of-the-art attack detection techniques in system generalization ability, detection stability, and overall detection performance.

  10. Characteristics of right-sided colonic neoplasia and colonoscopy barriers limiting their early detection and prognosis: a review of the literature.

    Science.gov (United States)

    Fischbach, Wolfgang; Elsome, Rory; Amlani, Bharat

    2018-06-05

    Colonoscopy provides less protection from colorectal cancer in the right colon than the left. Areas covered: This review examines patient outcomes and colonoscopy success rates to identify factors that limit the protective effect of colonoscopy in the right colon. The MEDLINE and Embase databases were searched for literature from 2000 onwards, on the long-term outcomes and differences in screening practice between the right and left colon. In total, 12 systematic reviews (including nine meta-analyses) and 44 primary data records were included. Differences in patient outcomes and colonoscopy practice were identified between the right and left colon, suggesting that several factors, many of which disproportionally affect the right colon, impact lesion detection rates. Shorter withdrawal times reduce detection rates, while longer times significantly increase detection; mostly of adenomas in the right colon. Colonoscope attachments often only show a significant improvement in detection rates in the right colon, suggesting detection is more challenging due to visibility of the right colonic mucosa. Higher bowel cleansing grades significantly improve detection rates in the right colon compared to the left. Expert commentary: These findings confirm the need for continued improvement of colonoscopy effectiveness, and obligatory quality assessment, overall and especially in the right colon.

  11. REANALYSIS OF F-STATISTIC GRAVITATIONAL-WAVE SEARCHES WITH THE HIGHER CRITICISM STATISTIC

    International Nuclear Information System (INIS)

    Bennett, M. F.; Melatos, A.; Delaigle, A.; Hall, P.

    2013-01-01

    We propose a new method of gravitational-wave detection using a modified form of higher criticism, a statistical technique introduced by Donoho and Jin. Higher criticism is designed to detect a group of sparse, weak sources, none of which are strong enough to be reliably estimated or detected individually. We apply higher criticism as a second-pass method to synthetic F-statistic and C-statistic data for a monochromatic periodic source in a binary system and quantify the improvement relative to the first-pass methods. We find that higher criticism on C-statistic data is more sensitive by ∼6% than the C-statistic alone under optimal conditions (i.e., binary orbit known exactly) and the relative advantage increases as the error in the orbital parameters increases. Higher criticism is robust even when the source is not monochromatic (e.g., phase-wandering in an accreting system). Applying higher criticism to a phase-wandering source over multiple time intervals gives a ∼> 30% increase in detectability with few assumptions about the frequency evolution. By contrast, in all-sky searches for unknown periodic sources, which are dominated by the brightest source, second-pass higher criticism does not provide any benefits over a first-pass search.

  12. Improved BER based on intensity noise alleviation using developed detection technique for incoherent SAC-OCDMA systems

    Science.gov (United States)

    Al-Khafaji, Hamza M. R.; Aljunid, S. A.; Fadhil, Hilal A.

    2012-06-01

    The major drawback of incoherent spectral-amplitude coding optical code-division multiple-access (SAC-OCDMA) systems is their inherent intensity noise originating due to the incoherency of the broadband light sources. In this paper, we propose a developed detection technique named the modified-AND subtraction detection for incoherent SAC-OCDMA systems. This detection technique is based upon decreasing the received signal strength during the decoding process by dividing the spectrum of the utilized code sequence. The proposed technique is capable of mitigating the intensity noise effect, as well as suppressing the multiple-access interference impact. Based on modified quadratic congruence (MQC) code, the analytical results reveal that the modified-AND detection offer best bit-error rate (BER) performance and enables MQC code to support higher transmission rate up to 1.25 Gb/s compared to conventional AND detection. Furthermore, we ascertained that the proposed technique enhances the system performance using a simulation experiment.

  13. Study on drug resistance of mycobacterium tuberculosis in patients with pulmonary tuberculosis by drug resistance gene detecting

    International Nuclear Information System (INIS)

    Wang Wei; Li Hongmin; Wu Xueqiong; Wang Ansheng; Ye Yixiu; Wang Zhongyuan; Liu Jinwei; Chen Hongbing; Lin Minggui; Wang Jinhe; Li Sumei; Jiang Ping; Feng Bai; Chen Dongjing

    2004-01-01

    To investigate drug resistance of mycobacterium tuberculosis in different age group, compare detecting effect of two methods and evaluate their the clinical application value, all of the strains of mycobacterium tuberculosis were tested for resistance to RFP, INH SM PZA and EMB by the absolute concentration method on Lowenstein-Jensen medium and the mutation of the rpoB, katG, rpsL, pncA and embB resistance genes in M. tuberculosis was tested by PCR-SSCP. In youth, middle and old age group, the rate of acquired drug resistance was 89.2%, 85.3% and 67.6% respectively, the gene mutation rate was 76.2%, 81.3% and 63.2% respectively. The rate of acquired drug resistance and multiple drug resistance in youth group was much higher than those in other groups. The gene mutation was correlated with drug resistance level of mycobacterium tuberculosis. The gene mutation rate was higher in strains isolated from high concentration resistance than those in strains isolated from low concentration resistance. The more irregular treatment was longer, the rate of drug resistance was higher. Acquired drug resistance varies in different age group. It suggested that surveillance of drug resistence in different age group should be taken seriously, especially in youth group. PCR - SSCP is a sensitive and specific method for rapid detecting rpoB, katG, rpsL, pncA and embB genes mutations of MTB. (authors)

  14. Change detection in multitemporal synthetic aperture radar images using dual-channel convolutional neural network

    Science.gov (United States)

    Liu, Tao; Li, Ying; Cao, Ying; Shen, Qiang

    2017-10-01

    This paper proposes a model of dual-channel convolutional neural network (CNN) that is designed for change detection in SAR images, in an effort to acquire higher detection accuracy and lower misclassification rate. This network model contains two parallel CNN channels, which can extract deep features from two multitemporal SAR images. For comparison and validation, the proposed method is tested along with other change detection algorithms on both simulated SAR images and real-world SAR images captured by different sensors. The experimental results demonstrate that the presented method outperforms the state-of-the-art techniques by a considerable margin.

  15. Regional geographic variations in kidney cancer incidence rates in European countries.

    Science.gov (United States)

    Li, Peng; Znaor, Ariana; Holcatova, Ivana; Fabianova, Eleonora; Mates, Dana; Wozniak, Magdalena B; Ferlay, Jacques; Scelo, Ghislaine

    2015-06-01

    Marked unexplained national variations in incidence rates of kidney cancer have been observed for decades in Europe. To investigate geographic variations at the regional level and identify European regions with high incidence rates of kidney cancer. Regional- and national-level incidence data were extracted from the Cancer Incidence in Five Continents databases, local cancer registry databases, and local published reports. World population age-standardised rates (ASRs) were calculated for the periods 2003-2007 and 1988-1992. Rates by period and sex were compared using map visualisation. During 2003-2007, the highest ASR was found in the Plzen region, Czech Republic (31.4/100,000 person-years in men). Other regions of the Czech Republic had ASRs of 18.6-27.5/100,000 in men, with a tendency for higher rates in regions south of Prague. Surrounding regions, including eastern Germany and regions of Slovakia and Austria, had medium-to-high incidence rates (13.0-16.8/100,000 in men). Three other areas in Europe showed higher incidence rates in men compared with the rest of the continent: Lithuania, Estonia, Latvia, and Belarus (15.0-17.6/100,000); Iceland (13.5/100,000), and northern Italy (up to 16.0/100,000). Similar regional differences were observed among women, with rates approximately half of those observed in men in the same region. In general, these regional geographic variations remained stable over the periods 1988-1992 and 2003-2007, although higher incidence rates were detected in the Baltic countries in 2003-2007. Several European regions show particularly high rates of kidney cancer incidence. Large variations were observed within countries covered by national health-care systems, implying that overdetection is not the major factor. We present regional geographic variations in kidney cancer incidence rates in Europe. We highlight several regions with high incidence rates where further studies should be conducted for cancer control and prevention. Copyright

  16. An Advanced Deep Learning Approach for Ki-67 Stained Hotspot Detection and Proliferation Rate Scoring for Prognostic Evaluation of Breast Cancer.

    Science.gov (United States)

    Saha, Monjoy; Chakraborty, Chandan; Arun, Indu; Ahmed, Rosina; Chatterjee, Sanjoy

    2017-06-12

    Being a non-histone protein, Ki-67 is one of the essential biomarkers for the immunohistochemical assessment of proliferation rate in breast cancer screening and grading. The Ki-67 signature is always sensitive to radiotherapy and chemotherapy. Due to random morphological, color and intensity variations of cell nuclei (immunopositive and immunonegative), manual/subjective assessment of Ki-67 scoring is error-prone and time-consuming. Hence, several machine learning approaches have been reported; nevertheless, none of them had worked on deep learning based hotspots detection and proliferation scoring. In this article, we suggest an advanced deep learning model for computerized recognition of candidate hotspots and subsequent proliferation rate scoring by quantifying Ki-67 appearance in breast cancer immunohistochemical images. Unlike existing Ki-67 scoring techniques, our methodology uses Gamma mixture model (GMM) with Expectation-Maximization for seed point detection and patch selection and deep learning, comprises with decision layer, for hotspots detection and proliferation scoring. Experimental results provide 93% precision, 0.88% recall and 0.91% F-score value. The model performance has also been compared with the pathologists' manual annotations and recently published articles. In future, the proposed deep learning framework will be highly reliable and beneficial to the junior and senior pathologists for fast and efficient Ki-67 scoring.

  17. Detection of Nosema bombycis by FTA cards and loop-mediated isothermal amplification (LAMP).

    Science.gov (United States)

    Yan, Wei; Shen, Zhongyuan; Tang, Xudong; Xu, Li; Li, Qianlong; Yue, Yajie; Xiao, Shengyan; Fu, Xuliang

    2014-10-01

    We successfully established a detection method which exhibited a markedly higher sensitivity than previously developed detection methods for Nosema bombycis by combining glass beads, FTA card, and LAMP. Spores of N. bombycis were first broken by acid-washed glass beads; the DNA was subsequently extracted and purified with the FTA card, and LAMP was performed using primers (LSU296) designed based on the sequence of the LSU rRNA of N. bombycis. The minimum detection concentration was 10 spores/mL. When this method was used to detect pebrine disease in silkworm egg, the detection rate for 500 silkworm eggs, in which only one egg was infected with N. bombycis, was 100 % under our optimized conditions. If the number of eggs in the sample increased to 800 or 1,000, the sample was divided into two equal portions, and the eggs were smashed with glass beads after the addition of 1 mL of TE buffer. The liquid in two tubes was later mixed and applied to the FTA card, and the detection rates were 100 %. Furthermore, the LAMP method established in our study could detect N. bombycis infection in silkworm 24 h earlier than microscopy.

  18. Detection of the circulating antigen 14-3-3 protein of Schistosoma japonicum by time-resolved fluoroimmunoassay in rabbits

    Directory of Open Access Journals (Sweden)

    Wang Jie

    2011-05-01

    Full Text Available Abstract Background Schistosomiasis remains a major public health concern that afflicts millions of people worldwide. Low levels of Schistosoma infection require more sensitive diagnostic methods. In this study, a time-resolved fluoroimmunoassay (TRFIA was developed for detecting the signal transduction protein 14-3-3, a circulating antigen of Schistosoma japonicum. Results The detection limit of 14-3-3-TRFIA was 0.78 ng/ml, with a linear measurement range from 0.78 to 800 ng/ml. The average intra-assay and inter-assay variability of this TRFIA was 8.9% and 12.2% respectively, and the mean recovery rate ranged from 92.1% to 115.5%. Within the first 21 days post-infection in rabbits, the positive rates of the 14-3-3-TRFIA were distinctly higher compared to ELISA. All these findings illustrate that 14-3-3-TRFIA has a higher detection efficacy and is a good early diagnostic method for active Schistosoma infection. Conclusions A sandwich TRFIA for detecting the circulating antigen 14-3-3 of S. japonicum has been developed, and has demonstrated to be a good potential diagnostic method for schistosomiasis.

  19. Detecting Weak Explosions at Local Distances by Fusing Multiple Geophysical Phenomenologies

    Energy Technology Data Exchange (ETDEWEB)

    Carmichael, Joshua D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Nemzek, Robert J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Arrowsmith, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sentz, Kari [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-23

    Comprehensive explosion monitoring requires the technical capability to identify certain signatures at low signal strengths. For particularly small, evasively conducted explosions, conventional monitoring methods that use single geophysical phenomenologies may produce marginal or absent detections. To address this challenge, we recorded coincident acoustic, seismic and radio-frequency emissions during the above-ground detonation of ~ 2-12 kg solid charges and assessed how waveform data could be fused to increase explosion-screening capability. Our data provided identifiable explosion signatures that we implemented as template-events in multichannel correlation detectors to search for similar, matching waveforms. We thereby observed that these highly sensitive correlation detectors missed explosive events when applied separately to data streams that were heavily contaminated with noise and signal clutter. By then adding the p-values of these statistics through Fisher’s combined probability test, we correctly identified the explosion signals at thresholds consistent with the false alarm rates of the correlation detectors. This resulting Fisher test thereby provided high-probability detections, zero false alarms, and higher theoretical detection capability. We conclude that inclusion of these fusion methods in routine monitoring operations will likely lower both detection thresholds for small explosions, while reducing false attribution rates.

  20. A Novel Immune-Inspired Shellcode Detection Algorithm Based on Hyperellipsoid Detectors

    Directory of Open Access Journals (Sweden)

    Tianliang Lu

    2018-01-01

    Full Text Available Shellcodes are machine language codes injected into target programs in the form of network packets or malformed files. Shellcodes can trigger buffer overflow vulnerability and execute malicious instructions. Signature matching technology used by antivirus software or intrusion detection system has low detection rate for unknown or polymorphic shellcodes; to solve such problem, an immune-inspired shellcode detection algorithm was proposed, named ISDA. Static analysis and dynamic analysis were both applied. The shellcodes were disassembled to assembly instructions during static analysis and, for dynamic analysis, the API function sequences of shellcodes were obtained by simulation execution to get the behavioral features of polymorphic shellcodes. The extracted features of shellcodes were encoded to antigens based on n-gram model. Immature detectors become mature after immune tolerance based on negative selection algorithm. To improve nonself space coverage rate, the immune detectors were encoded to hyperellipsoids. To generate better antibody offspring, the detectors were optimized through clonal selection algorithm with genetic mutation. Finally, shellcode samples were collected and tested, and result shows that the proposed method has higher detection accuracy for both nonencoded and polymorphic shellcodes.

  1. Toward a better understanding of the comparatively high prostate cancer incidence rates in Utah.

    Science.gov (United States)

    Merrill, Ray M; Hilton, Sterling C; Wiggins, Charles L; Sturgeon, Jared D

    2003-04-29

    This study assesses whether comparatively high prostate cancer incidence rates among white men in Utah represent higher rates among members of the Church of Jesus Christ of Latter-day Saints (LDS or Mormons), who comprise about 70% of the state's male population, and considers the potential influence screening has on these rates. Analyses are based on 14,693 histologically confirmed invasive prostate cancer cases among men aged 50 years and older identified through the Utah Cancer Registry between 1985 and 1999. Cancer records were linked to LDS Church membership records to determine LDS status. Poisson regression was used to derive rate ratios of LDS to nonLDS prostate cancer incidence, adjusted for age, disease stage, calendar time, and incidental detection. LDS men had a 31% (95% confidence interval, 26%-36%) higher incidence rate of prostate cancer than nonLDS men during the study period. Rates were consistently higher among LDS men over time (118% in 1985-88, 20% in 1989-92, 15% in 1993-1996, and 13% in 1997-99); age (13% in ages 50-59, 48% in ages 60-69, 28% in ages 70-79, and 16% in ages 80 and older); and stage (36% in local/regional and 17% in unstaged). An age- and stage-shift was observed for both LDS and nonLDS men, although more pronounced among LDS men. Comparatively high prostate cancer incidence rates among LDS men in Utah are explained, at least in part, by more aggressive screening among these men.

  2. Breast cancer: Early detection - increasing mortality rates; Mammacarcinom: Erfolgreiche Fruehdiagnose, steigende Mortalitaet

    Energy Technology Data Exchange (ETDEWEB)

    Paterok, E M [Universitaets-Frauenklinik, Erlangen (Germany); Siebzehnruebl, E [Universitaets-Frauenklinik, Erlangen (Germany); Schulz-Wendtland, R [Universitaets-Frauenklinik, Erlangen (Germany); Koch, T [Universitaets-Frauenklinik, Erlangen (Germany)

    1995-05-01

    Mammography, sonography and nmr imaging are the tools that will in all probability detect breast cancer at an early stage. NMR imaging is the most recently developed and most sophisticated high-tech method for the diagnosis of disorders of the mammary parenchyma. To ensure a better differentiation between benign and malignant changes, nmr imaging of the breast is carried out following paramagnetic opacification using intravenous gadolinium DTPA. Owing to their angiogenic potential and increased vascular permeability carcinomas are characterized by a significant contrast medium accumulation. The signal intensities of malignant tumours are therefore higher than those of the adjacent supporting and fatty tissues or the intact mammary parenchyma. (orig./VHE) [Deutsch] Die Diagnostik des fruehen Mammacarcinoms gelingt mit Hilfe der Mammographie, Sonographie und Kernspintomographie. Die Kernspintomographie stellt gegenwaertig das neueste und apparatetechnisch aufwendigste Verfahren zur Diagnostik der Mammaparenchymerkrankungen dar. Zur besseren Differenzierung von malignen und benignen Veraenderungen wird die Kernspintomographie der Brust nach intravenoeser Applikation des paramagnetischen Kontrastmittels Gadolinium-DTPA durchgefuehrt. Carcinome zeigen aufgrund ihrer angiogenetischen Potenz und ihrer erhoehten Gefaesswandpermeabilitaet eine signifikante Kontrastmittelanreicherung. Maligne Tumoren stellen sich deshalb signalreicher dar als das umliegende Stuetz-, Fettgewebe und gesundes Mammaparenchym. (orig./VHE)

  3. Probing the Cosmic Gamma-Ray Burst Rate with Trigger Simulations of the Swift Burst Alert Telescope

    Science.gov (United States)

    Lien, Amy; Sakamoto, Takanori; Gehrels, Neil; Palmer, David M.; Barthelmy, Scott D.; Graziani, Carlo; Cannizzo, John K.

    2013-01-01

    The gamma-ray burst (GRB) rate is essential for revealing the connection between GRBs, supernovae and stellar evolution. Additionally, the GRB rate at high redshift provides a strong probe of star formation history in the early universe. While hundreds of GRBs are observed by Swift, it remains difficult to determine the intrinsic GRB rate due to the complex trigger algorithm of Swift. Current studies of the GRB rate usually approximate the Swift trigger algorithm by a single detection threshold. However, unlike the previously own GRB instruments, Swift has over 500 trigger criteria based on photon count rate and additional image threshold for localization. To investigate possible systematic biases and explore the intrinsic GRB properties, we develop a program that is capable of simulating all the rate trigger criteria and mimicking the image threshold. Our simulations show that adopting the complex trigger algorithm of Swift increases the detection rate of dim bursts. As a result, our simulations suggest bursts need to be dimmer than previously expected to avoid over-producing the number of detections and to match with Swift observations. Moreover, our results indicate that these dim bursts are more likely to be high redshift events than low-luminosity GRBs. This would imply an even higher cosmic GRB rate at large redshifts than previous expectations based on star-formation rate measurements, unless other factors, such as the luminosity evolution, are taken into account. The GRB rate from our best result gives a total number of 4568 +825 -1429 GRBs per year that are beamed toward us in the whole universe.

  4. Increased Total Anesthetic Time Leads to Higher Rates of Surgical Site Infections in Spinal Fusions.

    Science.gov (United States)

    Puffer, Ross C; Murphy, Meghan; Maloney, Patrick; Kor, Daryl; Nassr, Ahmad; Freedman, Brett; Fogelson, Jeremy; Bydon, Mohamad

    2017-06-01

    A retrospective review of a consecutive series of spinal fusions comparing patient and procedural characteristics of patients who developed surgical site infections (SSIs) after spinal fusion. It is known that increased surgical time (incision to closure) is associated with a higher rate of postoperative SSIs. We sought to determine whether increased total anesthetic time (intubation to extubation) is a factor in the development of SSIs as well. In spine surgery for deformity and degenerative disease, SSI has been associated with operative time, revealing a nearly 10-fold increase in SSI rates in prolonged surgery. Surgical time is associated with infections in other surgical disciplines as well. No studies have reported whether total anesthetic time (intubation to extubation) has an association with SSIs. Surgical records were searched in a retrospective fashion to identify all spine fusion procedures performed between January 2010 and July 2012. All SSIs during that timeframe were recorded and compared with the list of cases performed between 2010 and 2012 in a case-control design. There were 20 (1.7%) SSIs in this fusion cohort. On univariate analyses of operative factors, there was a significant association between total anesthetic time (Infection 7.6 ± 0.5 hrs vs. no infection -6.0 ± 0.1 hrs, P operative time (infection 5.5 ± 0.4 hrs vs. no infection - 4.4 ± 0.06 hrs, P infections, whereas level of pathology and emergent surgery were not significant. On multivariate logistic analysis, BMI and total anesthetic time remained independent predictors of SSI whereas ASA status and operative time did not. Increasing BMI and total anesthetic time were independent predictors of SSIs in this cohort of over 1000 consecutive spinal fusions. 3.

  5. Mechanisms promoting higher growth rate in arctic than in temperate shorebirds

    NARCIS (Netherlands)

    Schekkerman, H.; Tulp, I.Y.M.; Piersma, T.; Visser, G.H.

    2003-01-01

    We compared prefledging growth, energy expenditure, and time budgets in the arctic-breeding red knot (Calidris canutus) to those in temperate shorebirds, to investigate how arctic chicks achieve a high growth rate despite energetic difficulties associated with precocial development in a cold

  6. Mechanisms promoting higher growth rate in arctic than in temperate shorebirds

    NARCIS (Netherlands)

    Schekkerman, H; Tulp, Ingrid; Piersma, T.; Visser, G.H.

    We compared prefledging growth, energy expenditure, and time budgets in the arctic-breeding red knot (Calidris canutus) to those in temperate shorebirds, to investigate how arctic chicks achieve a high growth rate despite energetic difficulties associated with precocial development in a cold

  7. Cortical volumes and atrophy rates in FTD-3 CHMP2B mutation carriers and related non-carriers

    DEFF Research Database (Denmark)

    Eskildsen, Simon F; Østergaard, Lasse R; Rodell, Anders B

    2008-01-01

    with a mean interval of 16 months and surface based cortical segmentation we measured cortical thickness and volume, and quantified atrophy rates. Cortical thickness and atrophy rates were averaged within major lobes and focal effects were determined by parametric statistical maps. The volumetric atrophy...... in the frontal and occipital lobes, and in the left temporal lobe. Results indicated that cortical thickness has a higher sensitivity for detecting small changes than whole-brain volumetric measures. Comparing mutation carriers with non-carriers revealed increased atrophy rates in mutation carriers bilaterally...

  8. Comparison of digital tomosynthesis and chest radiography for the detection of pulmonary nodules: systematic review and meta-analysis.

    Science.gov (United States)

    Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S

    2016-12-01

    To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.

  9. Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

    Science.gov (United States)

    Geertsema, Roger S; Lindsell, Claire E

    2015-09-01

    When IVC are directly exhausted from a rodent housing room, the air quality of the room can become independent of the intracage air quality and may reduce the need for high room ventilation rates. This study assessed the effect of decreasing the ventilation rate in rodent rooms using direct-exhaust IVC systems. The study was conducted over 16 wk and compared conditions in 8 rodent rooms that had ventilation rates of 5 to 6 air changes per hour (ACH) with those in rooms at 10 to 12 ACH. At the low ventilation rate, rooms had higher CO₂ concentrations, higher dew point temperature, and lower particulate levels and spent a greater percentage of time above the temperature set point than did rooms at the high rate. The levels of allergens and endotoxins in room air were the same regardless of the ventilation rate. Differences seen in parameters within cages at the 2 ventilation rates were operationally irrelevant. We detected no total volatile organic compounds in the room that were attributable to ammonia, regardless of the ventilation rate. Clearing the air of ethanol after a spill took longer at the low compared with high rate. However, ethanol clearance was faster at the low rate when the demand-control system was activated than at the high ventilation rate alone. Air quality in the room and in the cages were acceptable with room ventilation rates of 5 to 6 ACH in rodent rooms that use direct-exhaust IVC systems.

  10. Comparison of detection procedures of Mycoplasma hyopneumoniae, Mycoplasma hyosynoviae, and Mycoplasma hyorhinis in lungs, tonsils, and synovial fluid of slaughtered pigs and their distributions in Thailand.

    Science.gov (United States)

    Makhanon, Metta; Tummaruk, Padet; Thongkamkoon, Pacharee; Thanawongnuwech, Roongroje; Prapasarakul, Nuvee

    2012-02-01

    The aim of this study was to investigate whether direct PCR (DP) gave similar results to culture prior to PCR (CPP) for detecting mycoplasmas in different types of pig tissues. A total of 724 samples obtained from lungs, tonsils, or synovial fluids from 270 slaughtered pigs were used. The history of clinical signs, lung score, and the presence of joint lesions were recorded during sample collection. The rates of detection of Mycoplasma hyopneumoniae, Mycoplasma hyosynoviae, and Mycoplasma hyorhinis using both procedures were evaluated. The overall prevalences of M. hyopneumoniae, M. hyosynoviae, and M. hyorhinis were 40.3%, 12.3%, and 64.6%, respectively, and the detection rate depended on the sample type and the procedure used. With lung tissue, DP gave a higher detection rate for M. hyopneumoniae (77.4%) than CPP (38.5%). M. hyorhinis was detected by CPP at 15.6% and 18.1% and by DP at 31.5% and 5.2%, respectively. The positive rate derived from tonsil from CPP was closed to that of DP. Using synovial fluid could not yield any positive M. hyorhinis from CPP whereas 37.2% was positive from DP. In contrast, using sample tissue from lung and tonsil by CPP could show much higher positive number than that of DP. There was a significant relationship between joint lesion and M. hyorhinis detection by DP (P hyopneumoniae and M. hyorhinis detection by DP and CPP, respectively. Tonsil was likely the community of persistent M. hyosynoviae and M. hyorhinis with highly detection by CPP. Synovial fluid was apparently unsuitable for mycoplasmal culture. The accuracy of mycoplasmal detection may depend upon the type of sample relevant to the detection procedure used.

  11. Comparison of SPECT and CT in detecting skull base invasion in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zhang Li; Wang Jinchuan; Pu Nuo; Song Wenzhong; Chen Mingxi

    2002-01-01

    Objective: To investigate the detecting ability of single photon emission computed tomography (SPECT) and CT in skull base invasion in nasopharyngeal carcinoma. Methods: Sixty-three patients with nasopharyngeal carcinoma were examined by whole body and skull base SPECT and CT of nasopharynx and skull base before radiotherapy. The results were double-blind compared and evaluated. Results: The overall positive rates of skull base invasion detected by SPECT and CT were 63.5% and 25.4%. In patients with headache, cranial nerve palsy and both, they were 87.9%, 93.3%, 92.3% and 42.4%, 46.7%, 46.2%. In patients with T 1 + T 2 and T 3 + T 4 lesions, they were 37.5%, 90.3% and 0.0%, 51.6%. In patients with N 0 + N 1 and N 2 + N 3 lesions, they were 63.9%, 63.0% and 19.4%, 33.3%. The positive rates of SPECT were higher than those of CT (McNemar Test, P < 0.05). The conformation rate between SPECT and CT was 61.9% and the dissimilitude rate was 38.1%. Binary Logistic regression analysis showed that headache and T stages were risk factors of positive SPECT rate (ORheadache = 3.864, ORTstage= 6.422) while Tstage and Nstage were the risk factors for positive CT rate (ORTstage = 48.932, ORNstage = 2.860). Conclusions: The detection sensitivity of SPECT in skull base invasion in nasopharyngeal carcinoma is superior to that of CT. But its specificity is inferior to that of CT. The detecting results in SPECT are better related to symptoms, signs and stage. Combining headache and cranial nerve palsy with T and N stage, the authors may much improve the results of SPECT and CT in the detection of skull base invasion in nasopharyngeal carcinoma. Further study is warranted

  12. Development of 'Dose Rate Meter' android app for radiation detection using camera of smartphones and tablet

    International Nuclear Information System (INIS)

    Shaikh, Aatef; Sharma, M.K.; Kulkarni, M.S.; Romal, Jis; Gupta, A.; Chaudhury, P.

    2018-01-01

    An android app 'Dose Rate Meter' for gamma radiation field measurement over wide range using smart phone has been developed. The android app implements the cluster counting and high delta algorithm. The high delta algorithm processes multiple images captured by the camera. It is more sensitive at lower dose rates but it saturates at higher dose rates of the order of 1Gy/h and its response starts decreasing. Since, this algorithm analyses a number of images to compute the dose rate, it takes few minutes to process on a typical smart phone with 1 GB RAM, dual core processor and a clock in the range of 1GHz. However, the cluster count algorithm computes the results in a few seconds only as it operates on a single image but it can be used to measure dose rate only in the range of 5 mGy/h and above. Therefore, we have implemented the two algorithms in such a way that initially, the control goes to the cluster count algorithm and in case the dose rate is below 5mGy/h, it has provision to invoke the high delta algorithm, thereby covering a dose rate measurement range from μGy/h to Gy/h

  13. Development of a large-solid-angle and multi-device detection system for elemental analysis

    International Nuclear Information System (INIS)

    Satoh, T.; Ishii, K.; Kamiya, T.; Sakai, T.; Oikawa, M.; Arakawa, K.; Matsuyama, S.; Yamazaki, H.

    2003-01-01

    A new detection apparatus for both low energy X-rays like 1 keV and back scattered protons of MeV energy was developed. The detection apparatus consists of a large-solid-angle multi-device Si detector and a data acquisition system. The detector has 45 detection devices which are arranged in the shape of a pentagonal pyramid and fully cover a sample. A micro-beam irradiates the sample through the center of the pentagonal pyramid and X-rays emitted from the sample are detected in a solid angle of about 1.0 sr. This novel detection setup has about five times higher sensitivity than a conventional micro-PIXE camera. In addition, not only X-rays but back scattered protons can be detected, since the counting rate of back scattered protons per detection device is small despite lack of a passive absorber

  14. Mechanistic dissimilarities between environmentally-influenced fatigue-crack propagation at near-threshold and higher growth rates in lower-strength steels

    Energy Technology Data Exchange (ETDEWEB)

    Suresh, S.; Ritchie, R. O.

    1981-11-01

    The role of hydrogen gas in influencing fatigue crack propagation is examined for several classes of lower strength pressure vessel and piping steels. Based on measurements over a wide range of growth rates from 10/sup -8/ to 10/sup -2/ mm/cycle, crack propagation rates are found to be significantly higher in dehumidified gaseous hydrogen compared to moist air in two distinct regimes of crack growth, namely (i) at the intermediate range of growth typically above approx. 10/sup -5/ mm/cycle, and (ii) at the near-threshold region below approx. 10/sup -6/ mm/cycle approaching lattice dimensions per cycle. Both effects are seen at maximum stress intensities (K/sub max/) far below the sustained-load threshold stress intensity for hydrogen-assisted cracking (K/sub Iscc/). Characteristics of environmentally influenced fatigue crack growth in each regime are shown to be markedly different with regard to fractography and the effect of such variables as load ratio and frequency. It is concluded that the primary mechanisms responsible for the influence of the environment in each regime are distinctly different. Whereas corrosion fatigue behavior at intermediate growth rates can be attributed to hydrogen embrittlement processes, the primary role of moist environments at near-threshold levels is shown to involve a contribution from enhanced crack closure due to the formation of crack surface corrosion deposits at low load ratios.

  15. Transrectal real-time tissue elastography targeted biopsy coupled with peak strain index improves the detection of clinically important prostate cancer.

    Science.gov (United States)

    Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi

    2017-07-01

    The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.

  16. Auditory detection of an increment in the rate of a random process

    International Nuclear Information System (INIS)

    Brown, W.S.; Emmerich, D.S.

    1994-01-01

    Recent experiments have presented listeners with complex tonal stimuli consisting of components with values (i.e., intensities or frequencies) randomly sampled from probability distributions [e.g., R. A. Lutfi, J. Acoust. Soc. Am. 86, 934--944 (1989)]. In the present experiment, brief tones were presented at intervals corresponding to the intensity of a random process. Specifically, the intervals between tones were randomly selected from exponential probability functions. Listeners were asked to decide whether tones presented during a defined observation interval represented a ''noise'' process alone or the ''noise'' with a ''signal'' process added to it. The number of tones occurring in any observation interval is a Poisson variable; receiver operating characteristics (ROCs) arising from Poisson processes have been considered by Egan [Signal Detection Theory and ROC Analysis (Academic, New York, 1975)]. Several sets of noise and signal intensities and observation interval durations were selected which were expected to yield equivalent performance. Rating ROCs were generated based on subjects' responses in a single-interval, yes--no task. The performance levels achieved by listeners and the effects of intensity and duration are compared to those predicted for an ideal observer

  17. The detection rates and tumor clinical/pathological stages of whole-body FDG-PET cancer screening

    International Nuclear Information System (INIS)

    Ono, Ken; Omagari, Junichi; Ochiai, Reiji; Yoshida, Tsuyoshi; Kitagawa, Mami; Kobayashi, Hisashi; Yamashita, Yasuyuki

    2007-01-01

    Fluorodeoxyglucose (FDG)-positron emission tomography (PET) has been used for cancer screening, mainly in East-Asia, and cancers are found not infrequently. However, their stages have not been clarified. We examined the detection rates of various cancers using whole-body PET for the screening of cancers in asymptomatic individuals, focusing on their clinical and pathological stages. Whole-body PET was obtained as a part of our cancer screening program among 3,426 healthy subjects. All subjects participated in a course of PET examination in conjunction with conventional examinations including a medical questionnaire, tumor markers, immunological fecal occult blood test, neck and abdominal ultrasonography and whole body computed tomography. A diagnosis and staging was obtained by an analysis of the pathological findings or by an analysis of the clinical follow-up data. Malignant tumors were discovered in 65 lesions found in 3,426 participants (1.90%). The PET findings were true-positive in 46 of the 65 cancer cases. The cancers were found in the following organs: the colon 14; thyroid gland 10; stomach 7; lung 5; liver 3; breast 2; and one each in the kidney, gallbladder, esophagus, pancreas and retroperitoneum. The stages were as follows: stage 0 5, stage I 17, stage II 10, stage III 7, and stage IV 6. One was an unknown primary. There were 19 false-negative findings (0.6%) on PET. Six cancers (0.18%) were missed in our screening program. PET imaging has the potential to detect a wide variety of cancers at potentially curative stages. Most PET-negative cancers are early stage cancers, and thus can be detected using other conventional examinations such as endoscopy. (author)

  18. Heroin addicts have higher discount rates for delayed rewards than non-drug-using controls.

    Science.gov (United States)

    Kirby, K N; Petry, N M; Bickel, W K

    1999-03-01

    Fifty-six heroin addicts and 60 age-matched controls were offered choices between monetary rewards ($11-$80) available immediately and larger rewards ($25-$85) available after delays ranging from 1 week to 6 months. Participants had a 1-in-6 chance of winning a reward that they chose on one randomly selected trial. Delay-discounting rates were estimated from the pattern of participants' choices. The discounting model of impulsiveness (Ainslie, 1975) implies that delay-discounting rates are positively correlated with impulsiveness. On average, heroin addicts' discount rates were twice those of controls (p = .004), and discount rates were positively correlated with impulsivity as measured by self-report questionnaires (p discounting rate as a measure of impulsiveness, a characteristic associated with substance abuse.

  19. To use the brief psychiatric rating scale to detect disorganized speech in schizophrenia: Findings from the REAP-AP study

    Directory of Open Access Journals (Sweden)

    Yong Chon Park

    2018-02-01

    Full Text Available Our study aimed to assess the psychometric validity of the conceptual disorganization item and other items of the Brief Psychiatric Rating Scale (BPRS for detecting disorganized speech in patients with schizophrenia. We included 357 schizophrenia patients with disorganized speech and 1082 without disorganized speech from the survey centers in India, Indonesia, Japan, Malaysia, and Taiwan, using the data from the Research on Asian Psychotropic Patterns for Antipsychotics (REAP-AP study. After adjusting the effects of confounding variables, a binary logistic regression model was fitted to identify BPRS items independently associated with disorganized speech. Receiver operating characteristic (ROC curves were used to identify optimum cut-off scores and their sensitivities and specificities for detecting disorganized speech. After adjusting the effects of confounding variables, the fitted binary logistic regression model indicated that conceptual disorganization (P < 0.0001, uncooperativeness (P = 0.010 and excitement (P = 0.001 were independently associated with disorganized speech. The ROC curve revealed that the conceptual disorganization item could accurately detect disorganized speech in patients with schizophrenia both separately and in combination with uncooperativeness and excitement. The subscale for conceptual disorganization, uncooperativeness and excitement items in the BPRS is a promising psychometric tool for detecting disorganized speech.

  20. Seven tesla MRI improves detection of focal cortical dysplasia in patients with refractory focal epilepsy

    NARCIS (Netherlands)

    Veersema, Tim J; Ferrier, Cyrille H; van Eijsden, Pieter; Gosselaar, Peter H; Aronica, Eleonora; Visser, Fredy; Zwanenburg, Jaco M; de Kort, Gerard A P; Hendrikse, Jeroen; Luijten, Peter R; Braun, Kees P J

    Objective: The aim of this study is to determine whether the use of 7 tesla (T) MRI in clinical practice leads to higher detection rates of focal cortical dysplasias in possible candidates for epilepsy surgery. Methods: In our center patients are referred for 7 T MRI if lesional focal epilepsy is

  1. Nondestructive materials evaluation and imaging by higher harmonics

    International Nuclear Information System (INIS)

    Kawashima, Koichiro

    2012-01-01

    Nondestructive detection of material anormalities, degradation and tight cracks, in which the acoustic impedance mismatch is low, is rather difficult by conventional ultrasonic testing. A novel nonlinear ultrasonic technique, in particular, higher harmonic technique, utilizes the waveform distortion, which results from the interaction between anormalities and large amplitude tone-burst waves. This technique is not affected by acoustic impedance mismatch, therefore, it has possibility to detect such anormalities, degradation and tight cracks. A novel higher harmonic imaging technique is proposed and applied to detect and visualize local plastic deformation of SUS 304 plates, plastic zone in front of crack tip, weld bond contour of carbon steel, small inclusions in ODS steel fuel tubes, pitting damage of SUS 316 plates in mercury, shallow fatigue cracks of SUS 316 plates introduced by thermal fatigue, and inter-granular stress corrosion cracking, IGSCC, in welded plates simulated safe-ends for bonding dissimilar metals. (author)

  2. Passive acoustic monitoring to detect spawning in large-bodied catostomids

    Science.gov (United States)

    Straight, Carrie A.; Freeman, Byron J.; Freeman, Mary C.

    2014-01-01

    Documenting timing, locations, and intensity of spawning can provide valuable information for conservation and management of imperiled fishes. However, deep, turbid or turbulent water, or occurrence of spawning at night, can severely limit direct observations. We have developed and tested the use of passive acoustics to detect distinctive acoustic signatures associated with spawning events of two large-bodied catostomid species (River Redhorse Moxostoma carinatum and Robust Redhorse Moxostoma robustum) in river systems in north Georgia. We deployed a hydrophone with a recording unit at four different locations on four different dates when we could both record and observe spawning activity. Recordings captured 494 spawning events that we acoustically characterized using dominant frequency, 95% frequency, relative power, and duration. We similarly characterized 46 randomly selected ambient river noises. Dominant frequency did not differ between redhorse species and ranged from 172.3 to 14,987.1 Hz. Duration of spawning events ranged from 0.65 to 11.07 s, River Redhorse having longer durations than Robust Redhorse. Observed spawning events had significantly higher dominant and 95% frequencies than ambient river noises. We additionally tested software designed to automate acoustic detection. The automated detection configurations correctly identified 80–82% of known spawning events, and falsely indentified spawns 6–7% of the time when none occurred. These rates were combined over all recordings; rates were more variable among individual recordings. Longer spawning events were more likely to be detected. Combined with sufficient visual observations to ascertain species identities and to estimate detection error rates, passive acoustic recording provides a useful tool to study spawning frequency of large-bodied fishes that displace gravel during egg deposition, including several species of imperiled catostomids.

  3. Early PET imaging with [68]Ga-PSMA-11 increases the detection rate of local recurrence in prostate cancer patients with biochemical recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Uprimny, Christian; Kroiss, Alexander Stephan; Decristoforo, Clemens; Kendler, Dorota; Guggenberg, Elisabeth von; Nilica, Bernhard; Maffey-Steffan, Johanna; Di Santo, Gianpaolo; Virgolini, Irene Johanna [Medical University Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); Fritz, Josef [Medical University Innsbruck, Department of Medical Statistics, Informatics and Health Economics, Innsbruck (Austria); Bektic, Jasmin; Horninger, Wolfgang [Medical University Innsbruck, Department of Urology, Innsbruck (Austria)

    2017-09-15

    with and without urinary bladder activity (median starting time of 321 vs. 275 s p.i.; range: 281-491 vs. 243-311 s p.i.; p < 0.001). Median SUV{sub max} value of lesions suggestive of LR on early images was significantly higher in comparison to gluteal muscle, inguinal vessels and seminal vesicle/anastomosis (median SUV{sub max}: 5.9 vs. 1.9, 4.0 and 2.4, respectively). Performance of early imaging in {sup 68}Ga-PSMA-11 PET/CT in addition to whole-body scans 60 min p.i. increases the detection rate of local recurrence in PC patients with biochemical recurrence. Acquisition of early PET images should be started as early as 5 min p.i. in order to avoid disturbing tracer activity in the urinary bladder occuring at a later time point. (orig.)

  4. Education Pays, 2010: The Benefits of Higher Education for Individuals and Society. Trends in Higher Education Series

    Science.gov (United States)

    Baum, Sandy; Ma, Jennifer; Payea, Kathleen

    2010-01-01

    Students who attend institutions of higher education obtain a wide range of personal, financial, and other lifelong benefits; likewise, taxpayers and society as a whole derive a multitude of direct and indirect benefits when citizens have access to postsecondary education. Accordingly, uneven rates of participation in higher education across…

  5. [Detection of a higher incidence of pathologic somatic findings in globus sensation by use of high frequency cinematography].

    Science.gov (United States)

    Hannig, C; Wuttge-Hannig, A; Bockmeyer, M

    1987-07-01

    Since December 1984 303 patients have undergone examination in our Multidisciplinary Consultation Service for Swallowing Disorders; 117 of them were suffering from typical globus symptoms. We were able to increase the yield of detection of organic lesions by use of the technique of 35 mm film cineradiography with a rate of 50 frames/s. Frame-by-frame analysis and computer-assisted evaluation showed that 80% of the patients with globus symptoms suffered from one or more underlying organic diseases, which could often be treated later with success. We found an increased incidence of early hypopharyngeal diverticula, webs, and motility disorders of the upper esophageal sphincter often associated with gastro-esophageal reflux or weakness of the pharyngeal wall. Cineradiography proved to be a very important tool in the analysis of the pharyngeal swallow in globus pharyngis.

  6. The clinical significance of detection to heart rate deceleration capacity and heart rate variability in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Jiang-rong Zhou

    2015-01-01

    Full Text Available Objective: To study the change of heart rate deceleration capacity ( DC and heart rate variability in patients with chronic heart failure (CHF and its relationship with left ventricular ejection fraction (LVEF. Methods: DC, LVEF, time and frequency domain parameters of HRV were measured in 66 patients with CHF and 34 healthy adults (control group by using 24h Holter recordings and Echocardiography. The standard deviation of normal R-R intervals( SDNN, squares of differences between adjacent NN intervals ( RMSSD,low frequency power( LFn and high frequency power( HFn and the changes of LVEF were compared between  the two groups,the relationship between DC,LVEF and HRV were studied in patients with CHF. Results: The median value of DC in the patients with CHF was significantly lower than that in control group( 3.1 ± 2.4 ms vs 7.2 ± 1.3 ms,P <0.01.Incidence of abnormal DC in the CHF group was 57.5%,which was significantly higher than that in the control group (P <0.01.The HRV index, including SDNN、RMSSD、LFn、HFn, in the CHF group was significantly lower than that in normal control group (P < 0.01. Significant positive correlation between HRV index and LVEF were confirmed (P < 0.01. Conclusions: DC and HRV index are lower in patients with CHF and have a good correlation with the left ventricular ejection fraction.

  7. Detecting treatment-subgroup interactions in clustered data with generalized linear mixed-effects model trees.

    Science.gov (United States)

    Fokkema, M; Smits, N; Zeileis, A; Hothorn, T; Kelderman, H

    2017-10-25

    Identification of subgroups of patients for whom treatment A is more effective than treatment B, and vice versa, is of key importance to the development of personalized medicine. Tree-based algorithms are helpful tools for the detection of such interactions, but none of the available algorithms allow for taking into account clustered or nested dataset structures, which are particularly common in psychological research. Therefore, we propose the generalized linear mixed-effects model tree (GLMM tree) algorithm, which allows for the detection of treatment-subgroup interactions, while accounting for the clustered structure of a dataset. The algorithm uses model-based recursive partitioning to detect treatment-subgroup interactions, and a GLMM to estimate the random-effects parameters. In a simulation study, GLMM trees show higher accuracy in recovering treatment-subgroup interactions, higher predictive accuracy, and lower type II error rates than linear-model-based recursive partitioning and mixed-effects regression trees. Also, GLMM trees show somewhat higher predictive accuracy than linear mixed-effects models with pre-specified interaction effects, on average. We illustrate the application of GLMM trees on an individual patient-level data meta-analysis on treatments for depression. We conclude that GLMM trees are a promising exploratory tool for the detection of treatment-subgroup interactions in clustered datasets.

  8. Fast-Rate Capable Electrode Material with Higher Energy Density than LiFePO4: 4.2V LiVPO4F Synthesized by Scalable Single-Step Solid-State Reaction.

    Science.gov (United States)

    Kim, Minkyung; Lee, Seongsu; Kang, Byoungwoo

    2016-03-01

    Use of compounds that contain fluorine (F) as electrode materials in lithium ion batteries has been considered, but synthesizing single-phase samples of these compounds is a difficult task. Here, it is demonstrated that a simple scalable single-step solid-state process with additional fluorine source can obtain highly pure LiVPO 4 F. The resulting material with submicron particles achieves very high rate capability ≈100 mAh g -1 at 60 C-rate (1-min discharge) and even at 200 C-rate (18 s discharge). It retains superior capacity, ≈120 mAh g -1 at 10 C charge/10 C discharge rate (6-min) for 500 cycles with >95% retention efficiency. Furthermore, LiVPO 4 F shows low polarization even at high rates leading to higher operating potential >3.45 V (≈3.6 V at 60 C-rate), so it achieves high energy density. It is demonstrated for the first time that highly pure LiVPO 4 F can achieve high power capability comparable to LiFePO 4 and much higher energy density (≈521 Wh g -1 at 20 C-rate) than LiFePO 4 even without nanostructured particles. LiVPO 4 F can be a real substitute of LiFePO 4.

  9. Further evidence for elevated human minisatellite mutation rate in Belarus eight years after the Chernobyl accident

    International Nuclear Information System (INIS)

    Dubrova, Yuri E.; Buard, Jerome; Jeffreys, Alec J.; Nesterov, Valeri N.; Krouchinsky, Nicolay G.; Ostapenko, Vladislav A.; Vergnaud, Gilles; Giraudeau, Fabienne

    1997-01-01

    Analysis of germline mutation rate at human minisatellites among children born in areas of the Mogilev district of Belarus heavily polluted after the Chernobyl accident has been extended, both by recruiting more families from the affected region and by using five additional minisatellite probes, including multi-locus probe 33.6 and four hypervariable single-locus probes. These additional data confirmed a twofold higher mutation rate in exposed families compared with non-irradiated families from the United Kingdom. An elevated rate was seen at all three independent sets of minisatellites (detected separately by multi-locus probes 33.15, 33.6 and six single-locus probes), indicating a generalised increase in minisatellite germline mutation rate in the Belarus families. Within the Belarus cohort, mutation rate was significantly greater in families with higher parental radiation dose estimated for chronic external and internal exposure to caesium-137, consistent with radiation induction of germline mutation. The spectra of mutation seen in the unexposed and exposed families were indistinguishable, suggesting that increased mutation observed over multiple loci arises indirectly by some mechanism that enhances spontaneous minisatellite mutation

  10. Efficacy of computer-aided detection system for screening mammography

    International Nuclear Information System (INIS)

    Saito, Mioko; Ohnuki, Koji; Yamada, Takayuki; Saito, Haruo; Ishibashi, Tadashi; Ohuchi, Noriaki; Takahashi, Shoki

    2002-01-01

    A study was conducted to evaluate the efficacy of a computer-aided detection (CAD) system for screening mammography (MMG). Screening mammograms of 2,231 women aged over 50 yr were examined. Medio-lateral oblique (MLO) images were obtained, and two expert observers interpreted the mammograms by consensus. First, each mammogram was interpreted without the assistance of CAD, followed immediately by a re-evaluation of areas marked by the CAD system. Data were recorded to measure the effect of CAD on the recall rate, cancer detection rate and detection rate of masses, microcalcifications and other findings. The CAD system increased the recall rate from 2.3% to 2.6%. Six recalled cases were diagnosed as breast cancer pathologically, and CAD detected all of these lesions. Seven additional cases in which CAD detected abnormal findings had no malignancy. The detection rate of CAD for microcalcifications was high (95.0%). However, the detection rate for mass lesions and other findings was low (29.2% and 25.0% respectively). The false positivity rate was 0.13/film for microcalcifications, and 0.25/film for mass lesions. The efficacy of the CAD system for detecting microcalcifications on screening mammograms was confirmed. However, the low detection rate of mass lesions and relatively high rate of false positivity need to be further improved. (author)

  11. Detecting impacts of extreme events with ecological in situ monitoring networks

    Directory of Open Access Journals (Sweden)

    M. D. Mahecha

    2017-09-01

    Full Text Available Extreme hydrometeorological conditions typically impact ecophysiological processes on land. Satellite-based observations of the terrestrial biosphere provide an important reference for detecting and describing the spatiotemporal development of such events. However, in-depth investigations of ecological processes during extreme events require additional in situ observations. The question is whether the density of existing ecological in situ networks is sufficient for analysing the impact of extreme events, and what are expected event detection rates of ecological in situ networks of a given size. To assess these issues, we build a baseline of extreme reductions in the fraction of absorbed photosynthetically active radiation (FAPAR, identified by a new event detection method tailored to identify extremes of regional relevance. We then investigate the event detection success rates of hypothetical networks of varying sizes. Our results show that large extremes can be reliably detected with relatively small networks, but also reveal a linear decay of detection probabilities towards smaller extreme events in log–log space. For instance, networks with  ≈  100 randomly placed sites in Europe yield a  ≥  90 % chance of detecting the eight largest (typically very large extreme events; but only a  ≥  50 % chance of capturing the 39 largest events. These findings are consistent with probability-theoretic considerations, but the slopes of the decay rates deviate due to temporal autocorrelation and the exact implementation of the extreme event detection algorithm. Using the examples of AmeriFlux and NEON, we then investigate to what degree ecological in situ networks can capture extreme events of a given size. Consistent with our theoretical considerations, we find that today's systematically designed networks (i.e. NEON reliably detect the largest extremes, but that the extreme event detection rates are not higher than would

  12. Detection rates, trends in and factors affecting observed levels of selected volatile organic compounds in blood among US adolescents and adults.

    Science.gov (United States)

    Jain, Ram B

    2017-12-01

    Data from National Health and Nutrition Examination Survey were analyzed to evaluate detection rates, trend in and factors affecting the observed levels of 1,4-dichlorobenzene, benzene, ethylbenzene, o-xylene, styrene, toluene, and m/p-xylene among US adolescents and adults over 2005-2012. Over 2005-20102, among adolescents, detection rates declined by more than 50% for benzene, ethylbenzene, and o-xylene, and among adults, detection rates declined by more than 50% for ethylbenzene and o-xylene and by a little less than 50% for benzene. Among adults, adjusted levels of 1, 4-dichlorobenzene, benzene, ethylbenzene, o-xylene, toluene, and m/p-xylene decreased by 13.7%, 17.1%, 20%, 17.7%, 23.2%, and 18.7% respectively for every two-year survey cycle. Among adolescents, percentage decline in the levels of 1, 4-dichlorobenzene, benzene, ethylbenzene, o-xylene, styrene, toluene, and m/p-xylene was 15.2%, 21.4%, 19.3%, 16.1%, 47.8%, and 17.7% respectively for every two year survey period. The ratio of adjusted geometric means for adult smokers as compared to adult nonsmokers was 10.7 for benzene, 3.5 for ethylbenzene, 2.0 for o-xylene, 3.4 for styrene, 3.5 for toluene, and 2.2 for m/p-xylene. Among adolescents, gender did not affect the adjusted levels of any of the seven VOCs, and the order in which adjusted levels for 1, 4-dichlorobenzene by race/ethnicity was observed was: non-Hispanic white (0.038ng/mL)non-Hispanic black (0.178ng/mL) and most of the pairwise comparisons were statistically significantly different (pvs. 0.025ng/mL). For adults, gender did not affect the adjusted levels of 1, 4-dicholorobenzene, ethylbenzene, o-xylene, styrene, toluene, and m/p-xylene. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Exponential decay of GC content detected by strand-symmetric substitution rates influences the evolution of isochore structure.

    Science.gov (United States)

    Karro, J E; Peifer, M; Hardison, R C; Kollmann, M; von Grünberg, H H

    2008-02-01

    The distribution of guanine and cytosine nucleotides throughout a genome, or the GC content, is associated with numerous features in mammals; understanding the pattern and evolutionary history of GC content is crucial to our efforts to annotate the genome. The local GC content is decaying toward an equilibrium point, but the causes and rates of this decay, as well as the value of the equilibrium point, remain topics of debate. By comparing the results of 2 methods for estimating local substitution rates, we identify 620 Mb of the human genome in which the rates of the various types of nucleotide substitutions are the same on both strands. These strand-symmetric regions show an exponential decay of local GC content at a pace determined by local substitution rates. DNA segments subjected to higher rates experience disproportionately accelerated decay and are AT rich, whereas segments subjected to lower rates decay more slowly and are GC rich. Although we are unable to draw any conclusions about causal factors, the results support the hypothesis proposed by Khelifi A, Meunier J, Duret L, and Mouchiroud D (2006. GC content evolution of the human and mouse genomes: insights from the study of processed pseudogenes in regions of different recombination rates. J Mol Evol. 62:745-752.) that the isochore structure has been reshaped over time. If rate variation were a determining factor, then the current isochore structure of mammalian genomes could result from the local differences in substitution rates. We predict that under current conditions strand-symmetric portions of the human genome will stabilize at an average GC content of 30% (considerably less than the current 42%), thus confirming that the human genome has not yet reached equilibrium.

  14. Detection and clinical significance of serum autoantibodies in patients with myasthenia gravis

    Directory of Open Access Journals (Sweden)

    Yun LIU

    2016-10-01

    Full Text Available Objective To investigate the expressions and clinical significance of serum anti - acetylcholine receptor antibodies (AChR-Ab, anti-Titin antibodies (Titin-Ab, and anti-Ryanodine receptor antibodies (RyR-Ab in patients with myasthenia gravis (MG. Methods Serum AChR-Ab, Titin-Ab and RyR-Ab were detected with enzyme-linked immunosorbent assay (ELISA in 182 MG patients, 105 patients of other neurological diseases (OND and 62 normal controls. Results Serum AChR-Ab, Titin-Ab and RyR-Ab were detected positive respectively in 68.13% (124/182, 64.29% (117/182 and 67.03% (122/182 of patients in MG group. The positive rates of those antibodies in MG group were significantly higher than those in OND group (P = 0.000, for all and control group (P = 0.000, for all. When 3 antibodies coexisted, the sensitivity in the diagnosis of MG was 41.21%, with 99.40% of specificity. There was no significant difference in the positive rate of serum AChR-Ab, Titin-Ab and RyR-Ab between early-onset MG subgroup and late-onset MG subgroup (P > 0.05, for all. The positive rates of AChR-Ab were significantly higher in MG patients with thymoma than in those without thymoma (P = 0.004. There was no significant difference in the positive rate of Titin-Ab and RyR-Ab between MG with thymoma subgroup and MG without thymoma subgroup (P > 0.05, for all. The prevalence of AChR-Ab in generalized MG (GMG atients (Ⅱa and Ⅱb was higher than those in ocular MG (OMG patients (typeⅠ; P = 0.005, 0.012. There was no significant difference in the positive rate of Titin-Ab and RyR-Ab between GMG subgroup and OMG subgroup (P > 0.05, for all. Conclusions Serum AChR-Ab, Titin-Ab and RyR-Ab can be used as ndicators of the diagnosis of MG. Patients with 3 coexisted positive antibodies are highly suspected as MG. Higher AChR-Ab level in serum of OMG patients indicates the possibility of progressing to GMG. DOI: 10.3969/j.issn.1672-6731.2016.10.007

  15. Higher success rate with transcranial electrical stimulation of motor-evoked potentials using constant-voltage stimulation compared with constant-current stimulation in patients undergoing spinal surgery.

    Science.gov (United States)

    Shigematsu, Hideki; Kawaguchi, Masahiko; Hayashi, Hironobu; Takatani, Tsunenori; Iwata, Eiichiro; Tanaka, Masato; Okuda, Akinori; Morimoto, Yasuhiko; Masuda, Keisuke; Tanaka, Yuu; Tanaka, Yasuhito

    2017-10-01

    During spine surgery, the spinal cord is electrophysiologically monitored via transcranial electrical stimulation of motor-evoked potentials (TES-MEPs) to prevent injury. Transcranial electrical stimulation of motor-evoked potential involves the use of either constant-current or constant-voltage stimulation; however, there are few comparative data available regarding their ability to adequately elicit compound motor action potentials. We hypothesized that the success rates of TES-MEP recordings would be similar between constant-current and constant-voltage stimulations in patients undergoing spine surgery. The objective of this study was to compare the success rates of TES-MEP recordings between constant-current and constant-voltage stimulation. This is a prospective, within-subject study. Data from 100 patients undergoing spinal surgery at the cervical, thoracic, or lumbar level were analyzed. The success rates of the TES-MEP recordings from each muscle were examined. Transcranial electrical stimulation with constant-current and constant-voltage stimulations at the C3 and C4 electrode positions (international "10-20" system) was applied to each patient. Compound muscle action potentials were bilaterally recorded from the abductor pollicis brevis (APB), deltoid (Del), abductor hallucis (AH), tibialis anterior (TA), gastrocnemius (GC), and quadriceps (Quad) muscles. The success rates of the TES-MEP recordings from the right Del, right APB, bilateral Quad, right TA, right GC, and bilateral AH muscles were significantly higher using constant-voltage stimulation than those using constant-current stimulation. The overall success rates with constant-voltage and constant-current stimulations were 86.3% and 68.8%, respectively (risk ratio 1.25 [95% confidence interval: 1.20-1.31]). The success rates of TES-MEP recordings were higher using constant-voltage stimulation compared with constant-current stimulation in patients undergoing spinal surgery. Copyright © 2017

  16. An efficient algorithm for the detection of exposed and hidden wormhole attack

    International Nuclear Information System (INIS)

    Khan, Z.A.; Rehman, S.U.; Islam, M.H.

    2016-01-01

    MANETs (Mobile Ad Hoc Networks) are slowly integrating into our everyday lives, their most prominent uses are visible in the disaster and war struck areas where physical infrastructure is almost impossible or very hard to build. MANETs like other networks are facing the threat of malicious users and their activities. A number of attacks have been identified but the most severe of them is the wormhole attack which has the ability to succeed even in case of encrypted traffic and secure networks. Once wormhole is launched successfully, the severity increases by the fact that attackers can launch other attacks too. This paper presents a comprehensive algorithm for the detection of exposed as well as hidden wormhole attack while keeping the detection rate to maximum and at the same reducing false alarms. The algorithm does not require any extra hardware, time synchronization or any special type of nodes. The architecture consists of the combination of Routing Table, RTT (Round Trip Time) and RSSI (Received Signal Strength Indicator) for comprehensive detection of wormhole attack. The proposed technique is robust, light weight, has low resource requirements and provides real-time detection against the wormhole attack. Simulation results show that the algorithm is able to provide a higher detection rate, packet delivery ratio, negligible false alarms and is also better in terms of Ease of Implementation, Detection Accuracy/ Speed and processing overhead. (author)

  17. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  18. Detecting the honeycomb sandwich composite material's moisture impregnating defects by using infrared thermography technique

    International Nuclear Information System (INIS)

    Kwon, Koo Ahn; Choi, Man Yong; Park, Jeong Hak; Choi, Won Jae; Park, Hee Sang

    2017-01-01

    Many composite materials are used in the aerospace industry because of their excellent mechanical properties. However, the nature of aviation exposes these materials to high temperature and high moisture conditions depending on climate, location, and altitude. Therefore, the molecular arrangement chemical properties, and mechanical properties of composite materials can be changed under these conditions. As a result, surface disruptions and cracks can be created. Consequently, moisture-impregnating defects can be induced due to the crack and delamination of composite materials as they are repeatedly exposed to moisture absorption moisture release, fatigue environment, temperature changes, and fluid pressure changes. This study evaluates the possibility of detecting the moisture-impregnating defects of CFRP and GFRP honeycomb structure sandwich composite materials, which are the composite materials in the aircraft structure, by using an active infrared thermography technology among non-destructive testing methods. In all experiments, it was possible to distinguish the area and a number of CFRP composite materials more clearly than those of GFRP composite material. The highest detection rate was observed in the heating duration of 50 mHz and the low detection rate was at the heating duration of over 500 mHz. The reflection method showed a higher detection rate than the transmission method

  19. Computer-aided detection and automated CT volumetry of pulmonary nodules

    International Nuclear Information System (INIS)

    Marten, Katharina; Engelke, Christoph

    2007-01-01

    With use of multislice computed tomography (MSCT), small pulmonary nodules are being detected in vast numbers, constituting the majority of all noncalcified lung nodules. Although the prevalence of lung cancers among such lesions in lung cancer screening populations is low, their isolation may contribute to increased patient survival. Computer-aided diagnosis (CAD) has emerged as a diverse set of diagnostic tools to handle the large number of images in MSCT datasets and most importantly, includes automated detection and volumetry of pulmonary nodules. Current CAD systems can significantly enhance experienced radiologists' performance and outweigh human limitations in identifying small lesions and manually measuring their diameters, augment observer consistency in the interpretation of such examinations and may thus help to detect significantly higher rates of early malignomas and give more precise estimates on chemotherapy response than can radiologists alone. In this review, we give an overview of current CAD in lung nodule detection and volumetry and discuss their relative merits and limitations. (orig.)

  20. Leak detection device for control rod drive and detection method therefor

    International Nuclear Information System (INIS)

    Imasaki, Yoshio.

    1997-01-01

    The present invention provides a detection device for leak of cooling water from a sealed axial portion of control rod drives (CRD) disposed in a BWR type reactor and a monitoring method therefor. Namely, the CRD transfers rotation at the sealed axial portion and elevates/lowers a piston to insert/withdraw control rod into/from the reactor core. High pressure water is injected upon occurrence of scram to urge the piston upwardly thereby rapidly inserting the control rods. Leak detection pipelines are laid from the sealed axial portion. A flow glass is connected to the leak detection pipelines. Then, cooling water leaked from the sealed axial portion flows in the leak detection pipelines and flows into the flow glass. The flow rate of cooling water leaked from the sealed axial portion of the CRD can thus be detected by monitoring the flow glass. In addition, a flowmeter is connected to the leak detection pipelines, or the flowmeter and the flow glass are connected, and a flowmeter is connected downstream. Then, the flow rate of the leaked cooling water can be detected automatically. (I.S.)

  1. Multiparameter FLAER-based flow cytometry for screening of paroxysmal nocturnal hemoglobinuria enhances detection rates in patients with aplastic anemia.

    Science.gov (United States)

    Sachdeva, Man Updesh Singh; Varma, Neelam; Chandra, Dinesh; Bose, Parveen; Malhotra, Pankaj; Varma, Subhash

    2015-05-01

    Flow cytometry is the gold standard methodology for screening of paroxysmal nocturnal hemoglobinuria. In the last few years, proaerolysin conjugated with fluorescein (FLAER) has become an important component of antibody panel used for the detection of paroxysmal nocturnal hemoglobinuria (PNH) clone. This study aimed to compare PNH clone detection by flow cytometry in the pre-FLAER era versus the FLAER era. This was a retrospective analysis of 4 years and included 1004 individuals screened for PNH clone, either presenting as hemolytic anemia or as aplastic anemia. In the pre-FLAER time period, the RBCs and neutrophils were screened with antibodies against CD55 and CD59. With the introduction of FLAER, neutrophils were screened with FLAER/CD24/CD15 and monocytes with FLAER/CD14/CD33 combination. A comparative analysis was done for detection of PNH clone in aplastic anemia patients versus non-aplastic anemia patients, as well as between pre-FLAER and FLAER era. Out of a total of 1004 individuals, 59 (5.8%) were detected to have PNH clone positivity. The frequency of PNH clone detected in aplastic anemia and non-aplastic anemia groups was 12.02 and 3.36%, respectively. The detection rate of PNH clone increased from 4.5% (32/711) in the pre-FLAER era to 9.2% (27/293) with the introduction of FLAER. However, this increase could be attributed to increased detection of PNH clone in the aplastic anemia group, which showed a significant increase from 8.3 to 18.2% after use of FLAER. In the non-aplastic group, PNH clone was detected with similar frequencies before and after use of FLAER (3.2 versus 3.8%, respectively). Mean PNH clone size was lower in the aplastic anemia group when compared with the non-aplastic group. RBCs always showed a lower clone size than neutrophils. PNH clone on neutrophils and monocytes was however similar. Inclusion of FLAER increases the sensitivity of the test which is especially useful in picking up small PNH clones in patients of aplastic anemia.

  2. Detection and quantification of Sapovirus in bivalve molluscs from Galicia (NW Spain.

    Directory of Open Access Journals (Sweden)

    Jesus L Romalde

    2014-06-01

    SaV was detected in 30 of the 168 samples (17,85%. There was no significant difference between the two Rías in terms of detections, although it was observed a seasonality increment of positive samples from November 2011 until April 2012 in both Rías due to the rainy season and the decrease of seawater temperature. Total quantification ranged between 103 and 105 copies of viral RNA/g of digestive tissue (c/g, being mussels the specie with lower main quantification (3,1 x 104 c/g and clams the species with higher medium rates (2,0 x 105 c/g. This represents the first study out of Japan in which human Sapovirus was detected and quantified into human food intended for consumption.

  3. 123I-MIBG imaging detects cardiac involvement and predicts cardiac events in Churg-Strauss syndrome

    International Nuclear Information System (INIS)

    Horiguchi, Yoriko; Morita, Yukiko; Tsurikisawa, Naomi; Akiyama, Kazuo

    2011-01-01

    In Churg-Strauss syndrome (CSS) it is important to detect cardiac involvement, which predicts poor prognosis. This study evaluated whether 123 I-metaiodobenzylguanidine (MIBG) scintigraphy could detect cardiac damage and predict cardiac events in CSS. 123 I-MIBG scintigraphy was performed in 28 patients with CSS, 12 of whom had cardiac involvement. The early and delayed heart to mediastinum ratio (early H/M and delayed H/M) and washout rate were calculated by using 123 I-MIBG scintigraphy and compared with those in control subjects. Early H/M and delayed H/M were significantly lower and the washout rate was significantly higher in patients with cardiac involvement than in those without and in controls (early H/M, p = 0.0024, p = 0.0001; delayed H/M, p = 0.0002, p = 0.0001; washout rate, p = 0.0012, p = 0.0052 vs those without and vs controls, respectively). Accuracy for detecting cardiac involvement was 86% for delayed H/M and washout rate and 79% for early H/M and B-type natriuretic peptide (BNP). Kaplan-Meier analysis showed significantly lower cardiac event-free rates in patients with early H/M ≤ 2.18 and BNP > 21.8 pg/ml than those with early H/M > 2.18 and BNP ≤ 21.8 pg/ml (log-rank test p = 0.006). Cardiac sympathetic nerve function was damaged in CSS patients with cardiac involvement. 123 I-MIBG scintigraphy was useful in detecting cardiac involvement and in predicting cardiac events. (orig.)

  4. Ultrasensitive leak detection

    International Nuclear Information System (INIS)

    Winkelman, C.R.; Davidson, H.G.

    1978-01-01

    The objective of this investigation was to develop a method of detecting leaks to a sensitivity of 1.0 x 10 -13 std/cm 3 /s in vacuum devices and to develop a qualifiable standard leak to provide system calibration at this leak rate. The development work demonstrated that minimum detectable leak rates of 6.5 x 10 -14 std/cm 3 /s and 5.5 x 10 -15 std/cm 3 /s are possible for respective analog and digital measurement modes

  5. Sentinel lymph node mapping using SPECT/CT and gamma probe in endometrial cancer: an analysis of parameters affecting detection rate

    Energy Technology Data Exchange (ETDEWEB)

    Sahbai, Samine; La Fougere, Christian; Dittmann, Helmut [University Hospital Tuebingen, Nuclear Medicine and Clinical Molecular Imaging, Tuebingen (Germany); Taran, Florin-Andrei; Wallwiener, Diethelm; Brucker, Sara [University Hospital Tuebingen, Gynecology and Obstetrics, Tuebingen (Germany); Staebler, Annette [University Hospital Tuebingen, Pathology, Tuebingen (Germany)

    2017-08-15

    SPECT/CT after pericervical injection of technetium-99 m-nanocolloid was shown to be suitable for sentinel lymph node (SLN) mapping in endometrial cancer (EC). The aim of this study was to analyze factors affecting successful SLN detection by means of SPECT/CT such as imaging findings, patient characteristics and tumor biology in a large cohort of patients. One hundred and forty-five consecutive patients suffering from EC who received pre-surgical SLN mapping at our institution between 2011 and 2016 were included in this analysis. SPECT/CT data of abdomen and pelvis (mean 4:20 ± 1:20 h p.i.) were acquired after pericervical injection of technetium-99 m-nanocolloid (mean 230 ± 45 MBq) in all patients. Surgical staging was performed on the day after. Acquisition parameters, patient characteristics, SPECT/CT findings as well as histopathological results were collected. A total of 282 SLNs were identified by means of SPECT/CT. Overall, preoperative and intraoperative SLN detection rates were 86%, 76% and 74% respectively. The most important factor associated with failure to detect SLNs was the presence of high bone marrow on SPECT/CT (p = 0.005). Peritoneal/abdominal radioactivity was also associated with missed SLN detection in SPECT/CT (p = 0.02). However, the presence of liver/spleen uptake on its own was not predictive for detection failure. Low numbers of detected SLNs in SPECT/CT were slightly related with older age and lower injected activity. No significant influence was found for the parameters of tumor histology and stage, lymph node involvement and the time gap between injection and imaging. Venous drainage as indicated by bone marrow uptake is the most important factor associated with scintigraphic SLN detection failure. Moreover, high peritoneal and abdominal activity was also associated with detection failure. Thus, meticulous application of the radiotracer is crucial in EC. (orig.)

  6. Detection of Mycobacterium tuberculosis Complex in Paraffin-Embedded Tissues by the New Automated Abbott RealTime MTB Assay.

    Science.gov (United States)

    Fu, Yung-Chieh; Liao, I-Chuang; Chen, Hung-Mo; Yan, Jing-Jou

    2016-07-01

    The Abbott RealTime MTB assay, launched in June 2014, has been shown to have a competitive performance in the detection of the Mycobacterium tuberculosis (MTB) complex in respiratory specimens. The present study was conducted to investigate the usefulness of the Abbott MTB Realtime assay in the detection of MTB in formalin-fixed paraffin-embedded (FFPE) tissues. A total of 96 FFPE specimens obtained from microbiologically proven MTB cases (N=60) and nontuberculous Mycobacterium cases (N=36) were analyzed. The performance of the Abbott MTB Realtime assay was compared with that of the Roche Cobas TaqMan MTB assay. The overall sensitivity and specificity of the Abbott assay were 63.3% and 97.2%, respectively, compared with 11.7% and 100% for the Cobas assay. The detection rate of the Abbott assay was much higher among 37 acid-fast-positive specimens than among 23 acid-fast-negative specimens (89.3% versus 21.7%, respectively). The detection rate of the assay was higher among 29 resection specimens than among 31 small biopsy specimens (86.2% versus 41.9%, respectively). Our results suggest that the Abbott RealTime MTB assay can be used to differentiate MTB from nontuberculous mycobacterial infections in acid-fast-positive FFPE tissues. © 2016 by the Association of Clinical Scientists, Inc.

  7. Multi-GNSS high-rate RTK, PPP and novel direct phase observation processing method: application to precise dynamic displacement detection

    Science.gov (United States)

    Paziewski, Jacek; Sieradzki, Rafal; Baryla, Radoslaw

    2018-03-01

    This paper provides the methodology and performance assessment of multi-GNSS signal processing for the detection of small-scale high-rate dynamic displacements. For this purpose, we used methods of relative (RTK) and absolute positioning (PPP), and a novel direct signal processing approach. The first two methods are recognized as providing accurate information on position in many navigation and surveying applications. The latter is an innovative method for dynamic displacement determination with the use of GNSS phase signal processing. This method is based on the developed functional model with parametrized epoch-wise topocentric relative coordinates derived from filtered GNSS observations. Current regular kinematic PPP positioning, as well as medium/long range RTK, may not offer coordinate estimates with subcentimeter precision. Thus, extended processing strategies of absolute and relative GNSS positioning have been developed and applied for displacement detection. The study also aimed to comparatively analyze the developed methods as well as to analyze the impact of combined GPS and BDS processing and the dependence of the results of the relative methods on the baseline length. All the methods were implemented with in-house developed software allowing for high-rate precise GNSS positioning and signal processing. The phase and pseudorange observations collected with a rate of 50 Hz during the field test served as the experiment’s data set. The displacements at the rover station were triggered in the horizontal plane using a device which was designed and constructed to ensure a periodic motion of GNSS antenna with an amplitude of ~3 cm and a frequency of ~4.5 Hz. Finally, a medium range RTK, PPP, and direct phase observation processing method demonstrated the capability of providing reliable and consistent results with the precision of the determined dynamic displacements at the millimeter level. Specifically, the research shows that the standard deviation of

  8. Contrasting Patterns of Nucleotide Substitution Rates Provide Insight into Dynamic Evolution of Plastid and Mitochondrial Genomes of Geranium.

    Science.gov (United States)

    Park, Seongjun; Ruhlman, Tracey A; Weng, Mao-Lun; Hajrah, Nahid H; Sabir, Jamal S M; Jansen, Robert K

    2017-06-01

    Geraniaceae have emerged as a model system for investigating the causes and consequences of variation in plastid and mitochondrial genomes. Incredible structural variation in plastid genomes (plastomes) and highly accelerated evolutionary rates have been reported in selected lineages and functional groups of genes in both plastomes and mitochondrial genomes (mitogenomes), and these phenomena have been implicated in cytonuclear incompatibility. Previous organelle genome studies have included limited sampling of Geranium, the largest genus in the family with over 400 species. This study reports on rates and patterns of nucleotide substitutions in plastomes and mitogenomes of 17 species of Geranium and representatives of other Geraniaceae. As detected across other angiosperms, substitution rates in the plastome are 3.5 times higher than the mitogenome in most Geranium. However, in the branch leading to Geranium brycei/Geranium incanum mitochondrial genes experienced significantly higher dN and dS than plastid genes, a pattern that has only been detected in one other angiosperm. Furthermore, rate accelerations differ in the two organelle genomes with plastomes having increased dN and mitogenomes with increased dS. In the Geranium phaeum/Geranium reflexum clade, duplicate copies of clpP and rpoA genes that experienced asymmetric rate divergence were detected in the single copy region of the plastome. In the case of rpoA, the branch leading to G. phaeum/G. reflexum experienced positive selection or relaxation of purifying selection. Finally, the evolution of acetyl-CoA carboxylase is unusual in Geraniaceae because it is only the second angiosperm family where both prokaryotic and eukaryotic ACCases functionally coexist in the plastid. © The Author 2017. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  9. Standard and Nonstandard Neutrino-Nucleus Reactions Cross Sections and Event Rates to Neutrino Detection Experiments

    Directory of Open Access Journals (Sweden)

    D. K. Papoulias

    2015-01-01

    Full Text Available In this work, we explore ν-nucleus processes from a nuclear theory point of view and obtain results with high confidence level based on accurate nuclear structure cross sections calculations. Besides cross sections, the present study includes simulated signals expected to be recorded by nuclear detectors and differential event rates as well as total number of events predicted to be measured. Our original cross sections calculations are focused on measurable rates for the standard model process, but we also perform calculations for various channels of the nonstandard neutrino-nucleus reactions and come out with promising results within the current upper limits of the corresponding exotic parameters. We concentrate on the possibility of detecting (i supernova neutrinos by using massive detectors like those of the GERDA and SuperCDMS dark matter experiments and (ii laboratory neutrinos produced near the spallation neutron source facilities (at Oak Ridge National Lab by the COHERENT experiment. Our nuclear calculations take advantage of the relevant experimental sensitivity and employ the severe bounds extracted for the exotic parameters entering the Lagrangians of various particle physics models and specifically those resulting from the charged lepton flavour violating μ-→e- experiments (Mu2e and COMET experiments.

  10. A Novel Passive Islanding Detection Scheme for Distributed Generations Based on Rate of Change of Positive Sequence Component of Voltage and Current

    DEFF Research Database (Denmark)

    Rostami, Ali; Jalilian, Amin; Naderi, Seyed Behzad

    2017-01-01

    ) based wind turbine and synchronous diesel generator DGs by MATLAB/Simulink software. Different non-islanding case studies are taken into account to evaluate the effectiveness of the proposed approach. The simulation results show that the proposed method has advantage of detecting the islanding rapidly......Islanding operation is one of serious hazards of distributed generation (DG) applications. According to IEEE 1547 standard, its occurrence must be detected within two seconds. This paper presents a novel passive islanding detection method based on rate of change of positive sequence component...... of RCPSC and RCPSV exceed the predetermined threshold values, it is concluded that the islanding condition has occurred. Otherwise, it is considered as a non-islanding event. The performance of the proposed method is investigated on a sample network in the presence of doubly fed induction generator (DFIG...

  11. Experience with dynamic reinforcement rates decreases resistance to extinction.

    Science.gov (United States)

    Craig, Andrew R; Shahan, Timothy A

    2016-03-01

    The ability of organisms to detect reinforcer-rate changes in choice preparations is positively related to two factors: the magnitude of the change in rate and the frequency with which rates change. Gallistel (2012) suggested similar rate-detection processes are responsible for decreases in responding during operant extinction. Although effects of magnitude of change in reinforcer rate on resistance to extinction are well known (e.g., the partial-reinforcement-extinction effect), effects of frequency of changes in rate prior to extinction are unknown. Thus, the present experiments examined whether frequency of changes in baseline reinforcer rates impacts resistance to extinction. Pigeons pecked keys for variable-interval food under conditions where reinforcer rates were stable and where they changed within and between sessions. Overall reinforcer rates between conditions were controlled. In Experiment 1, resistance to extinction was lower following exposure to dynamic reinforcement schedules than to static schedules. Experiment 2 showed that resistance to presession feeding, a disruptor that should not involve change-detection processes, was unaffected by baseline-schedule dynamics. These findings are consistent with the suggestion that change detection contributes to extinction. We discuss implications of change-detection processes for extinction of simple and discriminated operant behavior and relate these processes to the behavioral-momentum based approach to understanding extinction. © 2016 Society for the Experimental Analysis of Behavior.

  12. Electro-optical muzzle flash detection

    Science.gov (United States)

    Krieg, Jürgen; Eisele, Christian; Seiffer, Dirk

    2016-10-01

    Localizing a shooter in a complex scenario is a difficult task. Acoustic sensors can be used to detect blast waves. Radar technology permits detection of the projectile. A third method is to detect the muzzle flash using electro-optical devices. Detection of muzzle flash events is possible with focal plane arrays, line and single element detectors. In this paper, we will show that the detection of a muzzle flash works well in the shortwave infrared spectral range. Important for the acceptance of an operational warning system in daily use is a very low false alarm rate. Using data from a detector with a high sampling rate the temporal signature of a potential muzzle flash event can be analyzed and the false alarm rate can be reduced. Another important issue is the realization of an omnidirectional view required on an operational level. It will be shown that a combination of single element detectors and simple optics in an appropriate configuration is a capable solution.

  13. Lung nodule detection on chest CT: evaluation of a computer-aided detection (CAD) system

    International Nuclear Information System (INIS)

    Lee, In Jae; Gamsu, Gordon; Czum, Julianna; Johnson, Rebecca; Chakrapani, Sanjay; Wu, Ning

    2005-01-01

    To evaluate the capacity of a computer-aided detection (CAD) system to detect lung nodules in clinical chest CT. A total of 210 consecutive clinical chest CT scans and their reports were reviewed by two chest radiologists and 70 were selected (33 without nodules and 37 with 1-6 nodules, 4-15.4 mm in diameter). The CAD system (ImageChecker CT LN-1000) developed by R2 Technology, Inc. (Sunnyvale, CA) was used. Its algorithm was designed to detect nodules with a diameter of 4-20 mm. The two chest radiologists working with the CAD system detected a total of 78 nodules. These 78 nodules form the database for this study. Four independent observers interpreted the studies with and without the CAD system. The detection rates of the four independent observers without CAD were 81% (63/78), 85% (66/78), 83% (65/78), and 83% (65/78), respectively. With CAD their rates were 87% (68/78), 85% (66/78), 86% (67/78), and 85% (66/78), respectively. The differences between these two sets of detection rates did not reach statistical significance. In addition, CAD detected eight nodules that were not mentioned in the original clinical radiology reports. The CAD system produced 1.56 false-positive nodules per CT study. The four test observers had 0, 0.1, 0.17, and 0.26 false-positive results per study without CAD and 0.07, 0.2, 0.23, and 0.39 with CAD, respectively. The CAD system can assist radiologists in detecting pulmonary nodules in chest CT, but with a potential increase in their false positive rates. Technological improvements to the system could increase the sensitivity and specificity for the detection of pulmonary nodules and reduce these false-positive results

  14. Incrementally Detecting Change Types of Spatial Area Object: A Hierarchical Matching Method Considering Change Process

    Directory of Open Access Journals (Sweden)

    Yanhui Wang

    2018-01-01

    Full Text Available Detecting and extracting the change types of spatial area objects can track area objects’ spatiotemporal change pattern and provide the change backtracking mechanism for incrementally updating spatial datasets. To respond to the problems of high complexity of detection methods, high redundancy rate of detection factors, and the low automation degree during incrementally update process, we take into account the change process of area objects in an integrated way and propose a hierarchical matching method to detect the nine types of changes of area objects, while minimizing the complexity of the algorithm and the redundancy rate of detection factors. We illustrate in details the identification, extraction, and database entry of change types, and how we achieve a close connection and organic coupling of incremental information extraction and object type-of-change detection so as to characterize the whole change process. The experimental results show that this method can successfully detect incremental information about area objects in practical applications, with the overall accuracy reaching above 90%, which is much higher than the existing weighted matching method, making it quite feasible and applicable. It helps establish the corresponding relation between new-version and old-version objects, and facilitate the linked update processing and quality control of spatial data.

  15. High mutation detection rate in the COL4A5 collagen gene in suspected Alport syndrome using PCR and direct DNA sequencing

    DEFF Research Database (Denmark)

    Martin, P; Heiskari, N; Zhou, J

    1998-01-01

    -amplified and sequenced from DNA of 50 randomly chosen patients with suspected Alport syndrome. Mutations were found in 41 patients, giving a mutation detection rate of 82%. Retrospective analysis of clinical data revealed that two of the cases might be autosomal. Although it could not be determined whether the remaining...

  16. Differential diagnostic value of combined detection of serum CA153, CEA and TPA levels in patients with breast tumor

    International Nuclear Information System (INIS)

    Ding Wei

    2007-01-01

    Objective: To assess the differential diagnostic value of combined detection of serum CA153, CEA and TPA levels in patients with breast tumor. Methods: Serum levels of CA153, CEA and TPA were measured with RIA in 269 patients with breast tumor and 150 controls. Results: The serum levels of CA153, CEA and TPA in patients with breast cancer were significantly higher than those in the patients with benign breast tumor and controls. The positive rate of CA153 was 63.8% in the patients with breast cancer and that of CEA and TPA was 22.4% and 62.1% respectively, with combined detection of CA153 and CEA, the positive rate was 69.8%, with CA153 and TPA combined, the positive rate was 87.1%, with the three marker combined, the positive rate was 90.5%. The specificity was 77.9% with CA153, 77.9% with CA153 and CEA, 71.9% with CA153 and TPA, and 73.4% with all the three markers combined. Conclusion: The positive rate was increased remarkably with combined detection of CA153, CEA and TPA, however the specificity was not much changed, so the combined detection was valuable for differential diagnosis. (authors)

  17. High Heating Rates Affect Greatly the Inactivation Rate of Escherichia coli

    Science.gov (United States)

    Huertas, Juan-Pablo; Aznar, Arantxa; Esnoz, Arturo; Fernández, Pablo S.; Iguaz, Asunción; Periago, Paula M.; Palop, Alfredo

    2016-01-01

    Heat resistance of microorganisms can be affected by different influencing factors. Although, the effect of heating rates has been scarcely explored by the scientific community, recent researches have unraveled its important effect on the thermal resistance of different species of vegetative bacteria. Typically heating rates described in the literature ranged from 1 to 20°C/min but the impact of much higher heating rates is unclear. The aim of this research was to explore the effect of different heating rates, such as those currently achieved in the heat exchangers used in the food industry, on the heat resistance of Escherichia coli. A pilot plant tubular heat exchanger and a thermoresistometer Mastia were used for this purpose. Results showed that fast heating rates had a deep impact on the thermal resistance of E. coli. Heating rates between 20 and 50°C/min were achieved in the heat exchanger, which were much slower than those around 20°C/s achieved in the thermoresistometer. In all cases, these high heating rates led to higher inactivation than expected: in the heat exchanger, for all the experiments performed, when the observed inactivation had reached about seven log cycles, the predictions estimated about 1 log cycle of inactivation; in the thermoresistometer these differences between observed and predicted values were even more than 10 times higher, from 4.07 log cycles observed to 0.34 predicted at a flow rate of 70 mL/min and a maximum heating rate of 14.7°C/s. A quantification of the impact of the heating rates on the level of inactivation achieved was established. These results point out the important effect that the heating rate has on the thermal resistance of E. coli, with high heating rates resulting in an additional sensitization to heat and therefore an effective food safety strategy in terms of food processing. PMID:27563300

  18. Effects of episodic sediment supply on bedload transport rate in mountain rivers. Detecting debris flow activity using continuous monitoring

    Science.gov (United States)

    Uchida, Taro; Sakurai, Wataru; Iuchi, Takuma; Izumiyama, Hiroaki; Borgatti, Lisa; Marcato, Gianluca; Pasuto, Alessandro

    2018-04-01

    Monitoring of sediment transport from hillslopes to channel networks as a consequence of floods with suspended and bedload transport, hyperconcentrated flows, debris and mud flows is essential not only for scientific issues, but also for prevention and mitigation of natural disasters, i.e. for hazard assessment, land use planning and design of torrent control interventions. In steep, potentially unstable terrains, ground-based continuous monitoring of hillslope and hydrological processes is still highly localized and expensive, especially in terms of manpower. In recent years, new seismic and acoustic methods have been developed for continuous bedload monitoring in mountain rivers. Since downstream bedload transport rate is controlled by upstream sediment supply from tributary channels and bed-external sources, continuous bedload monitoring might be an effective tool for detecting the sediments mobilized by debris flow processes in the upper catchment and thus represent an indirect method to monitor slope instability processes at the catchment scale. However, there is poor information about the effects of episodic sediment supply from upstream bed-external sources on downstream bedload transport rate at a single flood time scale. We have examined the effects of sediment supply due to upstream debris flow events on downstream bedload transport rate along the Yotagiri River, central Japan. To do this, we have conducted continuous bedload observations using a hydrophone (Japanese pipe microphone) located 6.4 km downstream the lower end of a tributary affected by debris flows. Two debris flows occurred during the two-years-long observation period. As expected, bedload transport rate for a given flow depth showed to be larger after storms triggering debris flows. That is, although the magnitude of sediment supply from debris flows is not large, their effect on bedload is propagating >6 km downstream at a single flood time scale. This indicates that continuous bedload

  19. Training in Using Earplugs or Using Earplugs with a Higher than Necessary Noise Reduction Rating? A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    M Salmani Nodoushan

    2014-09-01

    Full Text Available Background: Noise-induced hearing loss (NIHL is one of the most common occupational diseases and the second most common cause of workers' claims for occupational injuries. Objective: Due to high prevalence of NIHL and several reports of improper use of hearing protective devices (HPDs, we conducted this study to compare the effect of face-to-face training in effective use of earplugs with appropriate NRR to overprotection of workers by using earplugs with higher than necessary noise reduction rating (NRR. Methods: In a randomized clinical trial, 150 workers referred to occupational medicine clinic were randomly allocated to three arms—a group wearing earplugs with an NRR of 25 with no training in appropriate use of the device; a group wearing earplugs with an NRR of 25 with training; another group wearing earplugs with an NRR of 30, with no training. Hearing threshold was measured in the study groups by real ear attenuation at threshold (REAT method. This trial is registered with Australian New Zealand clinical trials Registry, number ACTRN00363175. Results: The mean±SD age of the participants was 28±5 (range: 19–39 years. 42% of participants were female. The mean noise attenuation in the group with training was 13.88 dB, significantly higher than those observed in other groups. The highest attenuation was observed in high frequencies (4, 6, and 8 kHz in the group with training. Conclusion: Training in appropriate use of earplugs significantly affects the efficacy of earplugs—even more than using an earplug with higher NRR.

  20. Implications of Binary Black Hole Detections on the Merger Rates of Double Neutron Stars and Neutron Star–Black Holes

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Anuradha; Arun, K. G.; Sathyaprakash, B. S., E-mail: axg645@psu.edu, E-mail: kgarun@cmi.ac.in, E-mail: bss25@psu.edu [Institute for Gravitation and Cosmos, Physics Department, Pennsylvania State University, University Park, PA 16802 (United States)

    2017-11-01

    We show that the inferred merger rate and chirp masses of binary black holes (BBHs) detected by advanced LIGO (aLIGO) can be used to constrain the rate of double neutron star (DNS) and neutron star–black hole (NSBH) mergers in the universe. We explicitly demonstrate this by considering a set of publicly available population synthesis models of Dominik et al. and show that if all the BBH mergers, GW150914, LVT151012, GW151226, and GW170104, observed by aLIGO arise from isolated binary evolution, the predicted DNS merger rate may be constrained to be 2.3–471.0 Gpc{sup −3} yr{sup −1} and that of NSBH mergers will be constrained to 0.2–48.5 Gpc{sup −3} yr{sup −1}. The DNS merger rates are not constrained much, but the NSBH rates are tightened by a factor of ∼4 as compared to their previous rates. Note that these constrained DNS and NSBH rates are extremely model-dependent and are compared to the unconstrained values 2.3–472.5 Gpc{sup −3} yr{sup −1} and 0.2–218 Gpc{sup −3} yr{sup −1}, respectively, using the same models of Dominik et al. (2012a). These rate estimates may have implications for short Gamma Ray Burst progenitor models assuming they are powered (solely) by DNS or NSBH mergers. While these results are based on a set of open access population synthesis models, which may not necessarily be the representative ones, the proposed method is very general and can be applied to any number of models, thereby yielding more realistic constraints on the DNS and NSBH merger rates from the inferred BBH merger rate and chirp mass.

  1. Implications of Binary Black Hole Detections on the Merger Rates of Double Neutron Stars and Neutron Star–Black Holes

    International Nuclear Information System (INIS)

    Gupta, Anuradha; Arun, K. G.; Sathyaprakash, B. S.

    2017-01-01

    We show that the inferred merger rate and chirp masses of binary black holes (BBHs) detected by advanced LIGO (aLIGO) can be used to constrain the rate of double neutron star (DNS) and neutron star–black hole (NSBH) mergers in the universe. We explicitly demonstrate this by considering a set of publicly available population synthesis models of Dominik et al. and show that if all the BBH mergers, GW150914, LVT151012, GW151226, and GW170104, observed by aLIGO arise from isolated binary evolution, the predicted DNS merger rate may be constrained to be 2.3–471.0 Gpc −3 yr −1 and that of NSBH mergers will be constrained to 0.2–48.5 Gpc −3 yr −1 . The DNS merger rates are not constrained much, but the NSBH rates are tightened by a factor of ∼4 as compared to their previous rates. Note that these constrained DNS and NSBH rates are extremely model-dependent and are compared to the unconstrained values 2.3–472.5 Gpc −3 yr −1 and 0.2–218 Gpc −3 yr −1 , respectively, using the same models of Dominik et al. (2012a). These rate estimates may have implications for short Gamma Ray Burst progenitor models assuming they are powered (solely) by DNS or NSBH mergers. While these results are based on a set of open access population synthesis models, which may not necessarily be the representative ones, the proposed method is very general and can be applied to any number of models, thereby yielding more realistic constraints on the DNS and NSBH merger rates from the inferred BBH merger rate and chirp mass.

  2. Older Adults With a Combination of Vision and Hearing Impairment Experience Higher Rates of Cognitive Impairment, Functional Dependence, and Worse Outcomes Across a Set of Quality Indicators.

    Science.gov (United States)

    Davidson, Jacob G S; Guthrie, Dawn M

    2017-08-01

    Hearing and vision impairment were examined across several health-related outcomes and across a set of quality indicators (QIs) in home care clients with both vision and hearing loss (or dual sensory impairment [DSI]). Data collected using the Resident Assessment Instrument for Home Care (RAI-HC) were analyzed in a sample of older home care clients. The QIs represent the proportion of clients experiencing negative outcomes (e.g., falls, social isolation). The average age of clients was 82.8 years ( SD = 7.9), 20.5% had DSI and 8.5% had a diagnosis of Alzheimer's disease (AD). Clients with DSI were more likely to have a diagnosis of dementia (not AD), have functional impairments, report loneliness, and have higher rates across 20 of the 22 QIs, including communication difficulty and cognitive decline. Clients with highly impaired hearing, and any visual impairment, had the highest QI rates. Individuals with DSI experience higher rates of adverse events across many health-related outcomes and QIs. Understanding the unique contribution of hearing and vision in this group can promote optimal quality of care.

  3. APPLICATION OF THE SPECTROMETRIC METHOD FOR CALCULATING THE DOSE RATE FOR CREATING CALIBRATION HIGHLY SENSITIVE INSTRUMENTS BASED ON SCINTILLATION DETECTION UNITS

    Directory of Open Access Journals (Sweden)

    R. V. Lukashevich

    2017-01-01

    Full Text Available Devices based on scintillation detector are highly sensitive to photon radiation and are widely used to measure the environment dose rate. Modernization of the measuring path to minimize the error in measuring the response of the detector to gamma radiation has already reached its technological ceiling and does not give the proper effect. More promising for this purpose are new methods of processing the obtained spectrometric information. The purpose of this work is the development of highly sensitive instruments based on scintillation detection units using a spectrometric method for calculating dose rate.In this paper we consider the spectrometric method of dosimetry of gamma radiation based on the transformation of the measured instrumental spectrum. Using predetermined or measured functions of the detector response to the action of gamma radiation of a given energy and flux density, a certain function of the energy G(E is determined. Using this function as the core of the integral transformation from the field to dose characteristic, it is possible to obtain the dose value directly from the current instrumentation spectrum. Applying the function G(E to the energy distribution of the fluence of photon radiation in the environment, the total dose rate can be determined without information on the distribution of radioisotopes in the environment.To determine G(E by Monte-Carlo method instrumental response function of the scintillator detector to monoenergetic photon radiation sources as well as other characteristics are calculated. Then the whole full-scale energy range is divided into energy ranges for which the function G(E is calculated using a linear interpolation.Spectrometric method for dose calculation using the function G(E, which allows the use of scintillation detection units for a wide range of dosimetry applications is considered in the article. As well as describes the method of calculating this function by using Monte-Carlo methods

  4. An opto-electronic joint detection system based on DSP aiming at early cervical cancer screening

    Science.gov (United States)

    Wang, Weiya; Jia, Mengyu; Gao, Feng; Yang, Lihong; Qu, Pengpeng; Zou, Changping; Liu, Pengxi; Zhao, Huijuan

    2015-02-01

    The cervical cancer screening at a pre-cancer stage is beneficial to reduce the mortality of women. An opto-electronic joint detection system based on DSP aiming at early cervical cancer screening is introduced in this paper. In this system, three electrodes alternately discharge to the cervical tissue and three light emitting diodes in different wavelengths alternately irradiate the cervical tissue. Then the relative optical reflectance and electrical voltage attenuation curve are obtained by optical and electrical detection, respectively. The system is based on DSP to attain the portable and cheap instrument. By adopting the relative reflectance and the voltage attenuation constant, the classification algorithm based on Support Vector Machine (SVM) discriminates abnormal cervical tissue from normal. We use particle swarm optimization to optimize the two key parameters of SVM, i.e. nuclear factor and cost factor. The clinical data were collected on 313 patients to build a clinical database of tissue responses under optical and electrical stimulations with the histopathologic examination as the gold standard. The classification result shows that the opto-electronic joint detection has higher total coincidence rate than separate optical detection or separate electrical detection. The sensitivity, specificity, and total coincidence rate increase with the increasing of sample numbers in the training set. The average total coincidence rate of the system can reach 85.1% compared with the histopathologic examination.

  5. Deception Detection: The Relationship of Levels of Trust and Perspective Taking in Real-Time Online and Offline Communication Environments.

    Science.gov (United States)

    Friend, Catherine; Fox Hamilton, Nicola

    2016-09-01

    Where humans have been found to detect lies or deception only at the rate of chance in offline face-to-face communication (F2F), computer-mediated communication (CMC) online can elicit higher rates of trust and sharing of personal information than F2F. How do levels of trust and empathetic personality traits like perspective taking (PT) relate to deception detection in real-time CMC compared to F2F? A between groups correlational design (N = 40) demonstrated that, through a paired deceptive conversation task with confederates, levels of participant trust could predict accurate detection online but not offline. Second, participant PT abilities could not predict accurate detection in either conversation medium. Finally, this study found that conversation medium also had no effect on deception detection. This study finds support for the effects of the Truth Bias and online disinhibition in deception, and further implications in law enforcement are discussed.

  6. "Terrain Paper" on Demography and Higher Education.

    Science.gov (United States)

    Hodgkinson, Harold L.

    Major demographic trends and consequences for higher education are examined. The Baby Boom sharply increased birth rates from 1946 to 1964 and was followed by a decline in births that lasted from 1964 to 1978. Currently there is an increased birth rate, but of much smaller size than the Baby Boom rates, due largely to the smaller size of the…

  7. Non-English speakers attend gastroenterology clinic appointments at higher rates than English speakers in a vulnerable patient population

    Science.gov (United States)

    Sewell, Justin L.; Kushel, Margot B.; Inadomi, John M.; Yee, Hal F.

    2009-01-01

    Goals We sought to identify factors associated with gastroenterology clinic attendance in an urban safety net healthcare system. Background Missed clinic appointments reduce the efficiency and availability of healthcare, but subspecialty clinic attendance among patients with established healthcare access has not been studied. Study We performed an observational study using secondary data from administrative sources to study patients referred to, and scheduled for an appointment in, the adult gastroenterology clinic serving the safety net healthcare system of San Francisco, California. Our dependent variable was whether subjects attended or missed a scheduled appointment. Analysis included multivariable logistic regression and classification tree analysis. 1,833 patients were referred and scheduled for an appointment between 05/2005 and 08/2006. Prisoners were excluded. All patients had a primary care provider. Results 683 patients (37.3%) missed their appointment; 1,150 (62.7%) attended. Language was highly associated with attendance in the logistic regression; non-English speakers were less likely than English speakers to miss an appointment (adjusted odds ratio 0.42 [0.28,0.63] for Spanish, 0.56 [0.38,0.82] for Asian language, p gastroenterology clinic appointment, not speaking English was most strongly associated with higher attendance rates. Patient related factors associated with not speaking English likely influence subspecialty clinic attendance rates, and these factors may differ from those affecting general healthcare access. PMID:19169147

  8. Monitoring of Non-Ferrous Wear Debris in Hydraulic Oil by Detecting the Equivalent Resistance of Inductive Sensors

    Directory of Open Access Journals (Sweden)

    Lin Zeng

    2018-03-01

    Full Text Available Wear debris in hydraulic oil contains important information on the operation of equipment, which is important for condition monitoring and fault diagnosis in mechanical equipment. A micro inductive sensor based on the inductive coulter principle is presented in this work. It consists of a straight micro-channel and a 3-D solenoid coil wound on the micro-channel. Instead of detecting the inductance change of the inductive sensor, the equivalent resistance change of the inductive sensor is detected for non-ferrous particle (copper particle monitoring. The simulation results show that the resistance change rate caused by the presence of copper particles is greater than the inductance change rate. Copper particles with sizes ranging from 48 μm to 150 μm were used in the experiment, and the experimental results are in good agreement with the simulation results. By detecting the inductive change of the micro inductive sensor, the detection limit of the copper particles only reaches 70 μm. However, the detection limit can be improved to 48 μm by detecting the equivalent resistance of the inductive sensor. The equivalent resistance method was demonstrated to have a higher detection accuracy than conventional inductive detection methods for non-ferrous particle detection in hydraulic oil.

  9. Optic disc detection and boundary extraction in retinal images.

    Science.gov (United States)

    Basit, A; Fraz, Muhammad Moazam

    2015-04-10

    With the development of digital image processing, analysis and modeling techniques, automatic retinal image analysis is emerging as an important screening tool for early detection of ophthalmologic disorders such as diabetic retinopathy and glaucoma. In this paper, a robust method for optic disc detection and extraction of the optic disc boundary is proposed to help in the development of computer-assisted diagnosis and treatment of such ophthalmic disease. The proposed method is based on morphological operations, smoothing filters, and the marker controlled watershed transform. Internal and external markers are used to first modify the gradient magnitude image and then the watershed transformation is applied on this modified gradient magnitude image for boundary extraction. This method has shown significant improvement over existing methods in terms of detection and boundary extraction of the optic disc. The proposed method has optic disc detection success rate of 100%, 100%, 100% and 98.9% for the DRIVE, Shifa, CHASE_DB1, and DIARETDB1 databases, respectively. The optic disc boundary detection achieved an average spatial overlap of 61.88%, 70.96%, 45.61%, and 54.69% for these databases, respectively, which are higher than currents methods.

  10. Three-minute constant rate step test for detecting exertional dyspnea relief after bronchodilation in COPD

    Directory of Open Access Journals (Sweden)

    Borel B

    2016-11-01

    Full Text Available Benoit Borel,1,2 Courtney A Wilkinson-Maitland,3 Alan Hamilton,4 Jean Bourbeau,5 Hélène Perrault,6 Dennis Jensen,3,5,7 François Maltais2 1Laboratoire HAVAE, Université de Limoges, Limoges, France; 2Centre de Recherche, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, Québec, 3Clinical Exercise and Respiratory Physiology Laboratory, Department of Kinesiology and Physical Education, McGill University, Montréal, QC, 4Boehringer Ingelheim (Canada Limited, Burlington, ON, 5Respiratory Epidemiology and Clinical Research Unit, Montreal Chest Institute, McGill University Health Center, Montreal, QC, 6Faculty of Health Sciences, University of Ottawa, Ottawa, ON, 7Translational Research in Respiratory Diseases Program, Research Institute of the McGill University Health Centre, Montreal, QC, Canada Background: The aim of this study was to evaluate the responsiveness of the 3-minute constant rate step test (3-MST to detect the relief of exertional dyspnea (respiratory discomfort after acute bronchodilation in COPD patients. Patients and methods: A total of 40 patients with moderate-to-severe COPD (mean forced expiratory volume in 1 second: 45.7 (±14.7, % predicted performed four 3-MSTs at randomly assigned stepping rates of 14, 16, 20 and 24 steps/min after inhalation of nebulized ipratropium bromide (500 µg/salbutamol (2.5 mg and saline placebo, which were randomized to order. Patients rated their intensity of perceived dyspnea at the end of each 3-MST using Borg 0–10 category ratio scale. Results: A total of 37 (92.5%, 36 (90%, 34 (85% and 27 (67.5% patients completed all 3 minutes of exercise at 14, 16, 20 and 24 steps/min under both treatment conditions, respectively. Compared with placebo, ipratropium bromide/salbutamol significantly decreased dyspnea at the end of the third minute of exercise at 14 steps/min (by 0.6±1.0 Borg 0–10 scale units, P<0.01 and 16 steps/min (by 0.7±1.3 Borg 0–10 scale

  11. Does the Adoption of Plagiarism-Detection Software in Higher Education Reduce Plagiarism?

    Science.gov (United States)

    Youmans, Robert J.

    2011-01-01

    In two studies, students at California State University, Northridge wrote papers that were checked for plagiarism using plagiarism-detection software. In the first study, half of the students in two classes were randomly selected and told by the professor that their term papers would be scanned for plagiarism using the software. Students in the…

  12. Estimation of flow rates through intergranular stress corrosion cracks

    International Nuclear Information System (INIS)

    Collier, R.P.; Norris, D.M.

    1984-01-01

    Experimental studies of critical two-phase water flow, through simulated and actual intergranular stress corrosion cracks, were performed to obtain data to evaluate a leak flow rate model and investigate acoustic transducer effectiveness in detecting and sizing leaks. The experimental program included a parametric study of the effects of crack geometry, fluid stagnation pressure and temperature, and crack surface roughness on leak flow rate. In addition, leak detection, location, and leak size estimation capabilities of several different acoustic transducers were evaluated as functions of leak rate and transducer position. This paper presents flow rate data for several different cracks and fluid conditions. It also presents the minimum flow rate detected with the acoustic sensors and a relationship between acoustic signal strength and leak flow rate

  13. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  14. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  15. MRI-detection rate and incidence of lumbar bleeding sources in 190 patients with non-aneurysmal SAH.

    Directory of Open Access Journals (Sweden)

    Sepide Kashefiolasl

    Full Text Available Up to 15% of all spontaneous subarachnoid hemorrhages (SAH have a non-aneurysmal SAH (NASAH. The evaluation of SAH patients with negative digital subtraction angiography (DSA is sometimes a diagnostic challenge. Our goal in this study was to reassess the yield of standard MR-imaging of the complete spinal axis to rule out spinal bleeding sources in patients with NASAH.We retrospectively analyzed the spinal MRI findings in 190 patients with spontaneous NASAH, containing perimesencephalic (PM and non-perimesencephalic (NPM SAH, diagnosed by computer tomography (CT and/or lumbar puncture (LP, and negative 2nd DSA.190 NASAH patients were included in the study, divided into PM-SAH (n = 87; 46% and NPM-SAH (n = 103; 54%. Overall, 23 (22% patients had a CT negative SAH, diagnosed by positive LP. MR-imaging of the spinal axis detected two patients with lumbar ependymoma (n = 2; 1,05%. Both patients complained of radicular sciatic pain. The detection rate raised up to 25%, if only patients with radicular sciatic pain received an MRI.Routine radiological investigation of the complete spinal axis in NASAH patients is expensive and can not be recommended for standard procedure. However, patients with clinical signs of low-back/sciatic pain should be worked up for a spinal pathology.

  16. Detection of Ground Clutter from Weather Radar Using a Dual-Polarization and Dual-Scan Method

    Directory of Open Access Journals (Sweden)

    Mohammad-Hossein Golbon-Haghighi

    2016-06-01

    Full Text Available A novel dual-polarization and dual-scan (DPDS classification algorithm is developed for clutter detection in weather radar observations. Two consecutive scans of dual-polarization radar echoes are jointly processed to estimate auto- and cross-correlation functions. Discriminants are then defined and estimated in order to separate clutter from weather based on their physical and statistical properties. An optimal Bayesian classifier is used to make a decision on clutter presence from the estimated discriminant functions. The DPDS algorithm is applied to the data collected with the KOUN polarimetric radar and compared with the existing detection methods. It is shown that the DPDS algorithm yields a higher probability of detection and lower false alarm rate in clutter detection.

  17. Natural-pose hand detection in low-resolution images

    Directory of Open Access Journals (Sweden)

    Nyan Bo Bo1

    2009-07-01

    Full Text Available Robust real-time hand detection and tracking in video sequences would enable many applications in areas as diverse ashuman-computer interaction, robotics, security and surveillance, and sign language-based systems. In this paper, we introducea new approach for detecting human hands that works on single, cluttered, low-resolution images. Our prototype system, whichis primarily intended for security applications in which the images are noisy and low-resolution, is able to detect hands as smallas 2424 pixels in cluttered scenes. The system uses grayscale appearance information to classify image sub-windows as eithercontaining or not containing a human hand very rapidly at the cost of a high false positive rate. To improve on the false positiverate of the main classifier without affecting its detection rate, we introduce a post-processor system that utilizes the geometricproperties of skin color blobs. When we test our detector on a test image set containing 106 hands, 92 of those hands aredetected (86.8% detection rate, with an average false positive rate of 1.19 false positive detections per image. The rapiddetection speed, the high detection rate of 86.8%, and the low false positive rate together ensure that our system is useable asthe main detector in a diverse variety of applications requiring robust hand detection and tracking in low-resolution, clutteredscenes.

  18. Remote detection of electronic devices

    Science.gov (United States)

    Judd, Stephen L [Los Alamos, NM; Fortgang, Clifford M [Los Alamos, NM; Guenther, David C [Los Alamos, NM

    2012-09-25

    An apparatus and method for detecting solid-state electronic devices are described. Non-linear junction detection techniques are combined with spread-spectrum encoding and cross correlation to increase the range and sensitivity of the non-linear junction detection and to permit the determination of the distances of the detected electronics. Nonlinear elements are detected by transmitting a signal at a chosen frequency and detecting higher harmonic signals that are returned from responding devices.

  19. Leflunomide is associated with a higher flare rate compared to methotrexate in the treatment of chronic uveitis in juvenile idiopathic arthritis.

    Science.gov (United States)

    Bichler, J; Benseler, S M; Krumrey-Langkammerer, M; Haas, J-P; Hügle, B

    2015-01-01

    Chronic anterior uveitis is a serious complication of juvenile idiopathic arthritis (JIA); disease flares are highly associated with loss of vision. Leflunomide (LEF) is used successfully for JIA joint disease but its effectiveness in uveitis has not been determined. The aim of this study was to determine whether LEF improves flare rates of uveitis in JIA patients compared to preceding methotrexate (MTX) therapy. A single-centre retrospective study of consecutive children with JIA and chronic anterior uveitis was performed. All children initially received MTX and were then switched to LEF. Demographic, clinical, and laboratory data, dose and duration of MTX and LEF therapy, concomitant medications and rate of anterior uveitis flares, as determined by an expert ophthalmologist, were obtained. Flare rates were compared using a generalized linear mixed model with a negative binomial distribution. A total of 15 children were included (80% females, all antinuclear antibody positive). The median duration of MTX therapy was 51 (range 26-167) months; LEF was given for a median of 12 (range 4-47) months. Anti-tumour necrosis factor (anti-TNF-α) co-medication was given to four children while on MTX. By contrast, LEF was combined with anti-TNF-α treatment in six children. On MTX, JIA patients showed a uveitis flare rate of 0.0247 flares/month, while LEF treatment was associated with a significantly higher flare rate of 0.0607 flares/month (p = 0.008). Children with JIA had significantly more uveitis flares on LEF compared to MTX despite receiving anti-TNF-α co-medication more frequently. Therefore, LEF may need to be considered less effective in controlling chronic anterior uveitis.

  20. Treatment of moderate acute malnutrition with ready-to-use supplementary food results in higher overall recovery rates compared with a corn-soya blend in children in southern Ethiopia: an operations research trial.

    Science.gov (United States)

    Karakochuk, Crystal; van den Briel, Tina; Stephens, Derek; Zlotkin, Stanley

    2012-10-01

    Moderate and severe acute malnutrition affects 13% of children malnutrition affects fewer children but is associated with higher rates of mortality and morbidity. Supplementary feeding programs aim to treat moderate acute malnutrition and prevent the deterioration to severe acute malnutrition. The aim was to compare recovery rates of children with moderate acute malnutrition in supplementary feeding programs by using the newly recommended ration of ready-to-use supplementary food (RUSF) and the more conventional ration of corn-soya blend (CSB) in Ethiopia. A total of 1125 children aged 6-60 mo with moderate acute malnutrition received 16 wk of CSB or RUSF. Children were randomly assigned to receive one or the other food. The daily rations were purposely based on the conventional treatment rations distributed at the time of the study in Ethiopia: 300 g CSB and 32 g vegetable oil in the control group (1413 kcal) and 92 g RUSF in the intervention group (500 kcal). The higher ration size of CSB was provided because of expected food sharing. The HR for children in the CSB group was 0.85 (95% CI: 0.73, 0.99), which indicated that they had 15% lower recovery (P = 0.039). Recovery rates of children at the end of the 16-wk treatment period trended higher in the RUSF group (73%) than in the CSB group (67%) (P = 0.056). In comparison with CSB, the treatment of moderate acute malnutrition with RUSF resulted in higher recovery rates in children, despite the large ration size and higher energy content of the conventional CSB ration.

  1. 3D Silicon Coincidence Avalanche Detector (3D-SiCAD) for charged particle detection

    Science.gov (United States)

    Vignetti, M. M.; Calmon, F.; Pittet, P.; Pares, G.; Cellier, R.; Quiquerez, L.; Chaves de Albuquerque, T.; Bechetoille, E.; Testa, E.; Lopez, J.-P.; Dauvergne, D.; Savoy-Navarro, A.

    2018-02-01

    Single-Photon Avalanche Diodes (SPADs) are p-n junctions operated in Geiger Mode by applying a reverse bias above the breakdown voltage. SPADs have the advantage of featuring single photon sensitivity with timing resolution in the picoseconds range. Nevertheless, their relatively high Dark Count Rate (DCR) is a major issue for charged particle detection, especially when it is much higher than the incoming particle rate. To tackle this issue, we have developed a 3D Silicon Coincidence Avalanche Detector (3D-SiCAD). This novel device implements two vertically aligned SPADs featuring on-chip electronics for the detection of coincident avalanche events occurring on both SPADs. Such a coincidence detection mode allows an efficient discrimination of events related to an incoming charged particle (producing a quasi-simultaneous activation of both SPADs) from dark counts occurring independently on each SPAD. A 3D-SiCAD detector prototype has been fabricated in CMOS technology adopting a 3D flip-chip integration technique, and the main results of its characterization are reported in this work. The particle detection efficiency and noise rejection capability for this novel device have been evaluated by means of a β- strontium-90 radioactive source. Moreover the impact of the main operating parameters (i.e. the hold-off time, the coincidence window duration, the SPAD excess bias voltage) over the particle detection efficiency has been studied. Measurements have been performed with different β- particles rates and show that a 3D-SiCAD device outperforms single SPAD detectors: the former is indeed capable to detect particle rates much lower than the individual DCR observed in a single SPAD-based detectors (i.e. 2 to 3 orders of magnitudes lower).

  2. BLACK HOLE ATTACK IN AODV & FRIEND FEATURES UNIQUE EXTRACTION TO DESIGN DETECTION ENGINE FOR INTRUSION DETECTION SYSTEM IN MOBILE ADHOC NETWORK

    Directory of Open Access Journals (Sweden)

    HUSAIN SHAHNAWAZ

    2012-10-01

    Full Text Available Ad-hoc network is a collection of nodes that are capable to form dynamically a temporary network without the support of any centralized fixed infrastructure. Since there is no central controller to determine the reliable & secure communication paths in Mobile Adhoc Network, each node in the ad hoc network has to rely on each other in order to forward packets, thus highly cooperative nodes are required to ensure that the initiated data transmission process does not fail. In a mobile ad hoc network (MANET where security is a crucial issue and they are forced to rely on the neighbor node, trust plays an important role that could improve the number of successful data transmission. Larger the number of trusted nodes, higher successful data communication process rates could be expected. In this paper, Black Hole attack is applied in the network, statistics are collected to design intrusion detection engine for MANET Intrusion Detection System (IDS. Feature extraction and rule inductions are applied to find out the accuracy of detection engine by using support vector machine. In this paper True Positive generated by the detection engine is very high and this is a novel approach in the area of Mobile Adhoc Intrusion detection system.

  3. Fusion of an Ensemble of Augmented Image Detectors for Robust Object Detection.

    Science.gov (United States)

    Wei, Pan; Ball, John E; Anderson, Derek T

    2018-03-17

    A significant challenge in object detection is accurate identification of an object's position in image space, whereas one algorithm with one set of parameters is usually not enough, and the fusion of multiple algorithms and/or parameters can lead to more robust results. Herein, a new computational intelligence fusion approach based on the dynamic analysis of agreement among object detection outputs is proposed. Furthermore, we propose an online versus just in training image augmentation strategy. Experiments comparing the results both with and without fusion are presented. We demonstrate that the augmented and fused combination results are the best, with respect to higher accuracy rates and reduction of outlier influences. The approach is demonstrated in the context of cone, pedestrian and box detection for Advanced Driver Assistance Systems (ADAS) applications.

  4. Fusion of an Ensemble of Augmented Image Detectors for Robust Object Detection

    Directory of Open Access Journals (Sweden)

    Pan Wei

    2018-03-01

    Full Text Available A significant challenge in object detection is accurate identification of an object’s position in image space, whereas one algorithm with one set of parameters is usually not enough, and the fusion of multiple algorithms and/or parameters can lead to more robust results. Herein, a new computational intelligence fusion approach based on the dynamic analysis of agreement among object detection outputs is proposed. Furthermore, we propose an online versus just in training image augmentation strategy. Experiments comparing the results both with and without fusion are presented. We demonstrate that the augmented and fused combination results are the best, with respect to higher accuracy rates and reduction of outlier influences. The approach is demonstrated in the context of cone, pedestrian and box detection for Advanced Driver Assistance Systems (ADAS applications.

  5. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  6. Effectiveness of high interest rate policy on exchange rates: A reexamination of the Asian financial crisis

    Directory of Open Access Journals (Sweden)

    Chin Diew Lai

    2006-09-01

    Full Text Available One of the most controversial issues in the aftermath of the Asian financial crisis has been the appropriate response of monetary policy to a sharp decline in the value of some currencies. In this paper, we empirically examine the effects on Asian exchange rates of sharply higher interest rates during the Asian financial crisis. Taking account of the currency contagion effect, our results indicate that sharply higher interest rates helped to support the exchange rates of South Korea, the Philippines, and Thailand. For Malaysia, no significant causal relation is found from the rate of interest to exchange rates, as the authorities in Malaysia did not actively adopt a high interest rate policy to defend the currency.

  7. Enhancing Brain Lesions during Acute Optic Neuritis and/or Longitudinally Extensive Transverse Myelitis May Portend a Higher Relapse Rate in Neuromyelitis Optica Spectrum Disorders.

    Science.gov (United States)

    Orman, G; Wang, K Y; Pekcevik, Y; Thompson, C B; Mealy, M; Levy, M; Izbudak, I

    2017-05-01

    Neuromyelitis optica spectrum disorders are inflammatory demyelinating disorders with optic neuritis and/or longitudinally extensive transverse myelitis episodes. We now know that neuromyelitis optica spectrum disorders are associated with antibodies to aquaporin-4, which are highly concentrated on astrocytic end-feet at the blood-brain barrier. Immune-mediated disruption of the blood-brain barrier may manifest as contrast enhancement on brain MR imaging. We aimed to delineate the extent and frequency of contrast enhancement on brain MR imaging within 1 month of optic neuritis and/or longitudinally extensive transverse myelitis attacks and to correlate contrast enhancement with outcome measures. Brain MRIs of patients with neuromyelitis optica spectrum disorders were evaluated for patterns of contrast enhancement (periependymal, cloudlike, leptomeningeal, and so forth). The Fisher exact test was used to evaluate differences between the proportion of contrast enhancement in patients who were seropositive and seronegative for aquaporin-4 antibodies. The Mann-Whitney test was used to compare the annualized relapse rate and disease duration between patients with and without contrast enhancement and with and without seropositivity. Brain MRIs of 77 patients were evaluated; 59 patients (10 males, 49 females) were scanned within 1 month of optic neuritis and/or longitudinally extensive transverse myelitis attacks and were included in the analysis. Forty-eight patients were seropositive, 9 were seronegative, and 2 were not tested for aquaporin-4 antibodies. Having brain contrast enhancement of any type during an acute attack was significantly associated with higher annualized relapse rates ( P = .03) and marginally associated with shorter disease duration ( P = .05). Having periependymal contrast enhancement was significantly associated with higher annualized relapse rates ( P = .03). Brain MRIs of patients with neuromyelitis optica spectrum disorders with contrast

  8. Global contrast based salient region detection

    KAUST Repository

    Cheng, Ming-Ming

    2011-08-25

    Reliable estimation of visual saliency allows appropriate processing of images without prior knowledge of their contents, and thus remains an important step in many computer vision tasks including image segmentation, object recognition, and adaptive compression. We propose a regional contrast based saliency extraction algorithm, which simultaneously evaluates global contrast differences and spatial coherence. The proposed algorithm is simple, efficient, and yields full resolution saliency maps. Our algorithm consistently outperformed existing saliency detection methods, yielding higher precision and better recall rates, when evaluated using one of the largest publicly available data sets. We also demonstrate how the extracted saliency map can be used to create high quality segmentation masks for subsequent image processing.

  9. Global contrast based salient region detection

    KAUST Repository

    Cheng, Ming-Ming; Zhang, Guo-Xin; Mitra, Niloy J.; Huang, Xiaolei; Hu, Shi-Min

    2011-01-01

    Reliable estimation of visual saliency allows appropriate processing of images without prior knowledge of their contents, and thus remains an important step in many computer vision tasks including image segmentation, object recognition, and adaptive compression. We propose a regional contrast based saliency extraction algorithm, which simultaneously evaluates global contrast differences and spatial coherence. The proposed algorithm is simple, efficient, and yields full resolution saliency maps. Our algorithm consistently outperformed existing saliency detection methods, yielding higher precision and better recall rates, when evaluated using one of the largest publicly available data sets. We also demonstrate how the extracted saliency map can be used to create high quality segmentation masks for subsequent image processing.

  10. Use of rapid-scan EPR to improve detection sensitivity for spin-trapped radicals.

    Science.gov (United States)

    Mitchell, Deborah G; Rosen, Gerald M; Tseitlin, Mark; Symmes, Breanna; Eaton, Sandra S; Eaton, Gareth R

    2013-07-16

    The short lifetime of superoxide and the low rates of formation expected in vivo make detection by standard continuous wave (CW) electron paramagnetic resonance (EPR) challenging. The new rapid-scan EPR method offers improved sensitivity for these types of samples. In rapid-scan EPR, the magnetic field is scanned through resonance in a time that is short relative to electron spin relaxation times, and data are processed to obtain the absorption spectrum. To validate the application of rapid-scan EPR to spin trapping, superoxide was generated by the reaction of xanthine oxidase and hypoxanthine with rates of 0.1-6.0 μM/min and trapped with 5-tert-butoxycarbonyl-5-methyl-1-pyrroline-N-oxide (BMPO). Spin trapping with BMPO to form the BMPO-OOH adduct converts the very short-lived superoxide radical into a more stable spin adduct. There is good agreement between the hyperfine splitting parameters obtained for BMPO-OOH by CW and rapid-scan EPR. For the same signal acquisition time, the signal/noise ratio is >40 times higher for rapid-scan than for CW EPR. Rapid-scan EPR can detect superoxide produced by Enterococcus faecalis at rates that are too low for detection by CW EPR. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  11. Steep Hard-X-ray Spectra Indicate Extremely High Accretion Rates in Weak Emission-Line Quasars

    Science.gov (United States)

    Marlar, Andrea; Shemmer, Ohad; Anderson, Scott F.; Brandt, W. Niel; Diamond-Stanic, Aleksandar M.; Fan, Xiaohui; Luo, Bin; Plotkin, Richard; Richards, Gordon T.; Schneider, Donald P.; Wu, Jianfeng

    2018-06-01

    We present XMM-Newton imaging spectroscopy of ten weak emission-line quasars (WLQs) at 0.928 ≤ z ≤ 3.767, six of which are radio quiet and four which are radio intermediate. The new X-ray data enabled us to measure the hard-X-ray power-law photon index (Γ) in each source with relatively high accuracy. These measurements allowed us to confirm previous reports that WLQs have steeper X-ray spectra, therefore indicating higher accretion rates with respect to "typical" quasars. A comparison between the Γ values of our radio-quiet WLQs and those of a carefully-selected, uniform sample of 84 quasars shows that the first are significantly higher, at the ≥ 3σ level. Collectively, the four radio-intermediate WLQs have lower Γ values with respect to the six radio-quiet WLQs, as may be expected if the spectra of the first group are contaminated by X-ray emission from a jet. These results suggest that, in the absence of significant jet emission along our line of sight, WLQs constitute the extreme high end of the accretion rate distribution in quasars. We detect soft excess emission in our lowest-redshift radio-quiet WLQ, in agreement with previous findings suggesting that the prominence of this feature is associated with a high accretion rate. We have not detected signatures of Compton reflection, Fe Kα lines, or strong variability between two X-ray epochs in any of our WLQs.

  12. A Fusion of Multiagent Functionalities for Effective Intrusion Detection System

    Directory of Open Access Journals (Sweden)

    Dhanalakshmi Krishnan Sadhasivan

    2017-01-01

    Full Text Available Provision of high security is one of the active research areas in the network applications. The failure in the centralized system based on the attacks provides less protection. Besides, the lack of update of new attacks arrival leads to the minimum accuracy of detection. The major focus of this paper is to improve the detection performance through the adaptive update of attacking information to the database. We propose an Adaptive Rule-Based Multiagent Intrusion Detection System (ARMA-IDS to detect the anomalies in the real-time datasets such as KDD and SCADA. Besides, the feedback loop provides the necessary update of attacks in the database that leads to the improvement in the detection accuracy. The combination of the rules and responsibilities for multiagents effectively detects the anomaly behavior, misuse of response, or relay reports of gas/water pipeline data in KDD and SCADA, respectively. The comparative analysis of the proposed ARMA-IDS with the various existing path mining methods, namely, random forest, JRip, a combination of AdaBoost/JRip, and common path mining on the SCADA dataset conveys that the effectiveness of the proposed ARMA-IDS in the real-time fault monitoring. Moreover, the proposed ARMA-IDS offers the higher detection rate in the SCADA and KDD cup 1999 datasets.

  13. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  14. Barium enema and endoscopy for the detection of colorectal neoplasia: Sensitivity, specificity, complications and its determinants

    International Nuclear Information System (INIS)

    Zwart, Ingrid M. de; Griffioen, Gerrit; Shaw, M. Pertaap Chandie; Lamers, Cornelis B.H.W.; Roos, Albert de

    2001-01-01

    AIM: To analyse sensitivity, specificity and complication rate of endoscopy, and barium enema for the detection of colorectal neoplasia. MATERIALS AND METHODS: A MEDLINE search was performed (1980-2000) directed at the endoscopic and radiologic literature on barium enema. Articles were selected based on the type of study, availability of sensitivity and specificity values in sizeable patient groups, and reports on complications. Sixty articles were included in the analysis. RESULTS: Endoscopy proved to have superior sensitivity for polyps in patients at high-risk for colorectal neoplasia. The role of endoscopy and radiology in average-risk screening populations is not known. Sensitivity and specificity rates ranged widely, probably due to bias. For the detection of small polyps endoscopy has superior performance, whereas sensitivity is similar for endoscopy and barium enema for the detection of larger (>1 cm) polyps and tumours. Overall, endoscopy is associated with a higher complication rate. CONCLUSION: Endoscopy is the preferred detection method in high-risk patients. The role of endoscopy and radiology in a screening setting requires evaluation. This review provides the test characteristics of endoscopy and radiology which are relevant for a cost-effectiveness analysis. Double-contrast barium enema may play an important role for screening purposes, owing to its good sensitivity for detecting larger (>1 cm) polyps and its lack of major complications. Zwart, I.M. de et al. (2001)

  15. Performance of mitochondrial DNA mutations detecting early stage cancer

    International Nuclear Information System (INIS)

    Jakupciak, John P; Srivastava, Sudhir; Sidransky, David; O'Connell, Catherine D; Maragh, Samantha; Markowitz, Maura E; Greenberg, Alissa K; Hoque, Mohammad O; Maitra, Anirban; Barker, Peter E; Wagner, Paul D; Rom, William N

    2008-01-01

    Mutations in the mitochondrial genome (mtgenome) have been associated with cancer and many other disorders. These mutations can be point mutations or deletions, or admixtures (heteroplasmy). The detection of mtDNA mutations in body fluids using resequencing microarrays, which are more sensitive than other sequencing methods, could provide a strategy to measure mutation loads in remote anatomical sites. We determined the mtDNA mutation load in the entire mitochondrial genome of 26 individuals with different early stage cancers (lung, bladder, kidney) and 12 heavy smokers without cancer. MtDNA was sequenced from three matched specimens (blood, tumor and body fluid) from each cancer patient and two matched specimens (blood and sputum) from smokers without cancer. The inherited wildtype sequence in the blood was compared to the sequences present in the tumor and body fluid, detected using the Affymetrix Genechip ® Human Mitochondrial Resequencing Array 1.0 and supplemented by capillary sequencing for noncoding region. Using this high-throughput method, 75% of the tumors were found to contain mtDNA mutations, higher than in our previous studies, and 36% of the body fluids from these cancer patients contained mtDNA mutations. Most of the mutations detected were heteroplasmic. A statistically significantly higher heteroplasmy rate occurred in tumor specimens when compared to both body fluid of cancer patients and sputum of controls, and in patient blood compared to blood of controls. Only 2 of the 12 sputum specimens from heavy smokers without cancer (17%) contained mtDNA mutations. Although patient mutations were spread throughout the mtDNA genome in the lung, bladder and kidney series, a statistically significant elevation of tRNA and ND complex mutations was detected in tumors. Our findings indicate comprehensive mtDNA resequencing can be a high-throughput tool for detecting mutations in clinical samples with potential applications for cancer detection, but it is

  16. Robust Adaptable Video Copy Detection

    DEFF Research Database (Denmark)

    Assent, Ira; Kremer, Hardy

    2009-01-01

    in contrast). Our query processing combines filtering and indexing structures for efficient multistep computation of video copies under this model. We show that our model successfully identifies altered video copies and does so more reliably than existing models.......Video copy detection should be capable of identifying video copies subject to alterations e.g. in video contrast or frame rates. We propose a video copy detection scheme that allows for adaptable detection of videos that are altered temporally (e.g. frame rate change) and/or visually (e.g. change...

  17. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  18. Using Generalized Entropies and OC-SVM with Mahalanobis Kernel for Detection and Classification of Anomalies in Network Traffic

    Directory of Open Access Journals (Sweden)

    Jayro Santiago-Paz

    2015-09-01

    an efficient computation time, while OC-SVM achieved detection rates slightly higher, but is more computationally expensive.

  19. Detecting the honeycomb sandwich composite material's moisture impregnating defects by using infrared thermography technique

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Koo Ahn; Choi, Man Yong; Park, Jeong Hak; Choi, Won Jae [Safety Measurement Center, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Park, Hee Sang [R and D, Korea Research Institute of Smart Material and Structures System Association, Daejeon (Korea, Republic of)

    2017-04-15

    Many composite materials are used in the aerospace industry because of their excellent mechanical properties. However, the nature of aviation exposes these materials to high temperature and high moisture conditions depending on climate, location, and altitude. Therefore, the molecular arrangement chemical properties, and mechanical properties of composite materials can be changed under these conditions. As a result, surface disruptions and cracks can be created. Consequently, moisture-impregnating defects can be induced due to the crack and delamination of composite materials as they are repeatedly exposed to moisture absorption moisture release, fatigue environment, temperature changes, and fluid pressure changes. This study evaluates the possibility of detecting the moisture-impregnating defects of CFRP and GFRP honeycomb structure sandwich composite materials, which are the composite materials in the aircraft structure, by using an active infrared thermography technology among non-destructive testing methods. In all experiments, it was possible to distinguish the area and a number of CFRP composite materials more clearly than those of GFRP composite material. The highest detection rate was observed in the heating duration of 50 mHz and the low detection rate was at the heating duration of over 500 mHz. The reflection method showed a higher detection rate than the transmission method.

  20. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  1. Real-time, wide-area hyperspectral imaging sensors for standoff detection of explosives and chemical warfare agents

    Science.gov (United States)

    Gomer, Nathaniel R.; Tazik, Shawna; Gardner, Charles W.; Nelson, Matthew P.

    2017-05-01

    Hyperspectral imaging (HSI) is a valuable tool for the detection and analysis of targets located within complex backgrounds. HSI can detect threat materials on environmental surfaces, where the concentration of the target of interest is often very low and is typically found within complex scenery. Unfortunately, current generation HSI systems have size, weight, and power limitations that prohibit their use for field-portable and/or real-time applications. Current generation systems commonly provide an inefficient area search rate, require close proximity to the target for screening, and/or are not capable of making real-time measurements. ChemImage Sensor Systems (CISS) is developing a variety of real-time, wide-field hyperspectral imaging systems that utilize shortwave infrared (SWIR) absorption and Raman spectroscopy. SWIR HSI sensors provide wide-area imagery with at or near real time detection speeds. Raman HSI sensors are being developed to overcome two obstacles present in standard Raman detection systems: slow area search rate (due to small laser spot sizes) and lack of eye-safety. SWIR HSI sensors have been integrated into mobile, robot based platforms and handheld variants for the detection of explosives and chemical warfare agents (CWAs). In addition, the fusion of these two technologies into a single system has shown the feasibility of using both techniques concurrently to provide higher probability of detection and lower false alarm rates. This paper will provide background on Raman and SWIR HSI, discuss the applications for these techniques, and provide an overview of novel CISS HSI sensors focusing on sensor design and detection results.

  2. Efficient Mining and Detection of Sequential Intrusion Patterns for Network Intrusion Detection Systems

    Science.gov (United States)

    Shyu, Mei-Ling; Huang, Zifang; Luo, Hongli

    In recent years, pervasive computing infrastructures have greatly improved the interaction between human and system. As we put more reliance on these computing infrastructures, we also face threats of network intrusion and/or any new forms of undesirable IT-based activities. Hence, network security has become an extremely important issue, which is closely connected with homeland security, business transactions, and people's daily life. Accurate and efficient intrusion detection technologies are required to safeguard the network systems and the critical information transmitted in the network systems. In this chapter, a novel network intrusion detection framework for mining and detecting sequential intrusion patterns is proposed. The proposed framework consists of a Collateral Representative Subspace Projection Modeling (C-RSPM) component for supervised classification, and an inter-transactional association rule mining method based on Layer Divided Modeling (LDM) for temporal pattern analysis. Experiments on the KDD99 data set and the traffic data set generated by a private LAN testbed show promising results with high detection rates, low processing time, and low false alarm rates in mining and detecting sequential intrusion detections.

  3. Pyrosequencing as a tool for the detection of Phytophthora species: error rate and risk of false Molecular Operational Taxonomic Units.

    Science.gov (United States)

    Vettraino, A M; Bonants, P; Tomassini, A; Bruni, N; Vannini, A

    2012-11-01

    To evaluate the accuracy of pyrosequencing for the description of Phytophthora communities in terms of taxa identification and risk of assignment for false Molecular Operational Taxonomic Units (MOTUs). Pyrosequencing of Internal Transcribed Spacer 1 (ITS1) amplicons was used to describe the structure of a DNA mixture comprising eight Phytophthora spp. and Pythium vexans. Pyrosequencing resulted in 16 965 reads, detecting all species in the template DNA mixture. Reducing the ITS1 sequence identity threshold resulted in a decrease in numbers of unmatched reads but a concomitant increase in the numbers of false MOTUs. The total error rate was 0·63% and comprised mainly mismatches (0·25%) Pyrosequencing of ITS1 region is an efficient and accurate technique for the detection and identification of Phytophthora spp. in environmental samples. However, the risk of allocating false MOTUs, even when demonstrated to be low, may require additional validation with alternative detection methods. Phytophthora spp. are considered among the most destructive groups of invasive plant pathogens, affecting thousands of cultivated and wild plants worldwide. Simultaneous early detection of Phytophthora complexes in environmental samples offers an unique opportunity for the interception of known and unknown species along pathways of introduction, along with the identification of these organisms in invaded environments. © 2012 The Authors Letters in Applied Microbiology © 2012 The Society for Applied Microbiology.

  4. A novel hardware implementation for detecting respiration rate using photoplethysmography.

    Science.gov (United States)

    Prinable, Joseph; Jones, Peter; Thamrin, Cindy; McEwan, Alistair

    2017-07-01

    Asthma is a serious public health problem. Continuous monitoring of breathing may offer an alternative way to assess disease status. In this paper we present a novel hardware implementation for the capture and storage of a photoplethysmography (PPG) signal. The LED duty cycle was altered to determine the effect on respiratory rate accuracy. The oximeter was mounted to the left index finger of ten healthy volunteers. The breathing rate derived from the oximeter was validated against a nasal airflow sensor. The duty cycle of a pulse oximeter was changed between 5%, 10% and 25% at a sample rate of 500 Hz. A PPG signal and reference signal was captured for each duty cycle. The PPG signals were post processed in Matlab to derive a respiration rate using an existing Matlab toolbox. At a 25% duty cycle the RMSE was <;2 breaths per minute for the top performing algorithm. The RMSE increased to over 5 breaths per minute when the duty cycle was reduced to 5%. The power consumed by the hardware for a 5%, 10% and 25% duty cycle was 5.4 mW, 7.8 mW, and 15 mW respectively. For clinical assessment of respiratory rate, a RSME of <;2 breaths per minute is recommended. Further work is required to determine utility in asthma management. However for non-clinical applications such as fitness tracking, lower accuracy may be sufficient to allow a reduced duty cycle setting.

  5. Testing Optimum Seeding Rates for five Bread Wheat Cultivars

    International Nuclear Information System (INIS)

    Wekesa, S.J.; Kiriswa, F.; Owuoche, J.

    1999-01-01

    A cultivar by seed rate trial was conducted in 1994-1995 crop seasons at Njoro, Kenya. Yield results were found to be significant (P > 0.01) for year, variety, seed rate and year by seed rate interaction. Test weight was highly significant (P -1 were grouped together for significantly higher yields (A) whereas seed rates 85 and 50 kg ha -1 had lower significant yields (B and C respectively). The same grouping was repeated for test weight. There was no significant cultivar by seed rate interaction and no cultivar, specific seed rate. However, since seed rates 245, 205, 165 and 125 kg ha -1 were grouped together, the lowest seed rate, 125 kg ha -1 can be recommended as the optimum seed rate for the above cultivars, as higher seed rates do not give significantly higher yields or higher test weights

  6. Detecting First Supernovae with JWST

    Science.gov (United States)

    Regos, Eniko; FLARE

    2018-01-01

    We have applied for a JWST ERS First Transients Survey, FLARE to answer empirically how the Universe made its first stars. To quest the epoch of reionization we target what happened to these first stars by observing the most luminous events, supernovae. These transients provide direct constraints on star formation rates and the initial mass function.These very rare events can be reached by JWST at 27 mag AB in 2 micron and 4.4 micron over a field of 0.1 square degree visited multiple times each year.The survey may detect massive Pop III SNe at redshifts up to 10, pinpointing the redshift of first stars, a key scientific goal of JWST.We explore all models of star formation history (derived from UV luminosity densities and IR data), DTD, top heavy IMF of early, low metallicity stars, and normalizations to data of SN Ia, II rates (SNLS, CLASH, CANDELS, SDSS, SVISS), as well as SLSN (ROTSE, SNLS) to estimate the expected SN rates as function of redshift.Population synthesis of double degenerate and single degenerate scenarios of SN Ia shows that the shape of the DTD is rather insensitive to the assumptions (common envelope prescription and metallicities, or retention efficiency of accreted H to white dwarf core and mass transfer rate).Indeed GOODS High z SN Ia rates imply substantial delay in their progenitor model, and Hubble Higher z SN search constrains delay time distribution models as well.SLSN (I, II /H/ and extreme rare pulsational pair instability) are magnetars (ULGRB) in high local star formation rate, faint, low metallicity galaxies.

  7. Is patriarchy the source of men's higher mortality?

    Science.gov (United States)

    Stanistreet, D; Bambra, C; Scott-Samuel, A

    2005-01-01

    Objective: To examine the relation between levels of patriarchy and male health by comparing female homicide rates with male mortality within countries. Hypothesis: High levels of patriarchy in a society are associated with increased mortality among men. Design: Cross sectional ecological study design. Setting: 51 countries from four continents were represented in the data—America, Europe, Australasia, and Asia. No data were available for Africa. Results: A multivariate stepwise linear regression model was used. Main outcome measure was age standardised male mortality rates for 51 countries for the year 1995. Age standardised female homicide rates and GDP per capita ranking were the explanatory variables in the model. Results were also adjusted for the effects of general rates of homicide. Age standardised female homicide rates and ranking of GDP were strongly correlated with age standardised male mortality rates (Pearson's r = 0.699 and Spearman's 0.744 respectively) and both correlations achieved significance (ppatriarchy, the higher is the rate of mortality among men. Conclusion: These data suggest that oppression and exploitation harm the oppressors as well as those they oppress, and that men's higher mortality is a preventable social condition, which could be tackled through global social policy measures. PMID:16166362

  8. Strain Rate Effect on Tensile Behavior for a High Specific Strength Steel: From Quasi-Static to Intermediate Strain Rates

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2017-12-01

    Full Text Available The strain rate effect on the tensile behaviors of a high specific strength steel (HSSS with dual-phase microstructure has been investigated. The yield strength, the ultimate strength and the tensile toughness were all observed to increase with increasing strain rates at the range of 0.0006 to 56/s, rendering this HSSS as an excellent candidate for an energy absorber in the automobile industry, since vehicle crushing often happens at intermediate strain rates. Back stress hardening has been found to play an important role for this HSSS due to load transfer and strain partitioning between two phases, and a higher strain rate could cause even higher strain partitioning in the softer austenite grains, delaying the deformation instability. Deformation twins are observed in the austenite grains at all strain rates to facilitate the uniform tensile deformation. The B2 phase (FeAl intermetallic compound is less deformable at higher strain rates, resulting in easier brittle fracture in B2 particles, smaller dimple size and a higher density of phase interfaces in final fracture surfaces. Thus, more energy need be consumed during the final fracture for the experiments conducted at higher strain rates, resulting in better tensile toughness.

  9. HIV positivity but not HPV/p16 status is associated with higher recurrence rate in anal cancer.

    Science.gov (United States)

    Meyer, Joshua E; Panico, Vinicius J A; Marconato, Heloisa M F; Sherr, David L; Christos, Paul; Pirog, Edyta C

    2013-12-01

    .06). The regional and distant failure rate was not related to HPV/p16 positivity or histologic differentiation of ACA; however, HIV positivity appeared to be associated with a higher recurrence rate and worse recurrence-free survival.

  10. Improved detection of congestive heart failure via probabilistic symbolic pattern recognition and heart rate variability metrics.

    Science.gov (United States)

    Mahajan, Ruhi; Viangteeravat, Teeradache; Akbilgic, Oguz

    2017-12-01

    A timely diagnosis of congestive heart failure (CHF) is crucial to evade a life-threatening event. This paper presents a novel probabilistic symbol pattern recognition (PSPR) approach to detect CHF in subjects from their cardiac interbeat (R-R) intervals. PSPR discretizes each continuous R-R interval time series by mapping them onto an eight-symbol alphabet and then models the pattern transition behavior in the symbolic representation of the series. The PSPR-based analysis of the discretized series from 107 subjects (69 normal and 38 CHF subjects) yielded discernible features to distinguish normal subjects and subjects with CHF. In addition to PSPR features, we also extracted features using the time-domain heart rate variability measures such as average and standard deviation of R-R intervals. An ensemble of bagged decision trees was used to classify two groups resulting in a five-fold cross-validation accuracy, specificity, and sensitivity of 98.1%, 100%, and 94.7%, respectively. However, a 20% holdout validation yielded an accuracy, specificity, and sensitivity of 99.5%, 100%, and 98.57%, respectively. Results from this study suggest that features obtained with the combination of PSPR and long-term heart rate variability measures can be used in developing automated CHF diagnosis tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Annoyance, detection and recognition of wind turbine noise.

    Science.gov (United States)

    Van Renterghem, Timothy; Bockstael, Annelies; De Weirt, Valentine; Botteldooren, Dick

    2013-07-01

    Annoyance, recognition and detection of noise from a single wind turbine were studied by means of a two-stage listening experiment with 50 participants with normal hearing abilities. In-situ recordings made at close distance from a 1.8-MW wind turbine operating at 22 rpm were mixed with road traffic noise, and processed to simulate indoor sound pressure levels at LAeq 40 dBA. In a first part, where people were unaware of the true purpose of the experiment, samples were played during a quiet leisure activity. Under these conditions, pure wind turbine noise gave very similar annoyance ratings as unmixed highway noise at the same equivalent level, while annoyance by local road traffic noise was significantly higher. In a second experiment, listeners were asked to identify the sample containing wind turbine noise in a paired comparison test. The detection limit of wind turbine noise in presence of highway noise was estimated to be as low as a signal-to-noise ratio of -23 dBA. When mixed with local road traffic, such a detection limit could not be determined. These findings support that noticing the sound could be an important aspect of wind turbine noise annoyance at the low equivalent levels typically observed indoors in practice. Participants that easily recognized wind-turbine(-like) sounds could detect wind turbine noise better when submersed in road traffic noise. Recognition of wind turbine sounds is also linked to higher annoyance. Awareness of the source is therefore a relevant aspect of wind turbine noise perception which is consistent with previous research. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. A hybrid positron and OCT intraoperative probe for ovarian cancer detection and characterization

    Science.gov (United States)

    Yang, Yi; Biswal, Nrusingh C.; Wang, Tianheng; Kumavor, Patrick; Karimeddini, Mozafareddin; Sanders, Melinda; Brewer, Molly; Zhu, Quing

    2011-03-01

    Ovarian cancer has the lowest survival rate of the gynecologic cancers with a 5-year survival of about 50% in the United States. With current screening and diagnostic abilities for ovarian cancers, most of the diagnosed patients are already with advanced stages and the majority of them will die of this deadly disease. In this paper, we report a multimodal imaging approach which combines optical coherence tomography (OCT) and positron detection for early ovarian cancer detection. The dual modality system has the capability of providing both functional and morphological images simultaneously. While the positron detection provides the metabolism activity of the ovary due to the uptake of radiotracer, the OCT provides the high resolution (25μm X 25μm X 12μm - longitudinal X lateral X axial in air) structural imaging at 20k A-lines per second. Total 18 ovaries obtained from 10 patients classified as normal, abnormal and malignant ovarian tissues were characterized ex vivo. Positron counts of 1.2-fold higher was found between abnormal and normal ovaries and 3~30-fold higher was found between malignant and normal ovaries. OCT imaging of malignant and abnormal ovaries revealed many detailed morphologic features that could be potentially valuable for detecting early malignant changes in the ovary.

  13. The value and limitations of contrast-enhanced transrectal ultrasonography for the detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Han-Xue, E-mail: zhaohx861@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Xia, Chun-Xia, E-mail: star9901482@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Yin, Hong-Xia, E-mail: hongxia_yin79@yahoo.com.cn [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Guo, Ning, E-mail: ningguo99@sina.com.cn [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Zhu, Qiang, E-mail: qzhutrhos@gmail.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China)

    2013-11-01

    Objectives: To evaluate the role of contrast-enhanced transrectal ultrasonography (CE-TRUS) for detecting prostate carcinoma. Methods: Sixty-five patients with elevated serum prostate-specific antigen (PSA) and/or abnormal digital rectal examination (DRE) were assessed using transrectal ultrasound (TRUS) and CE-TRUS. In all the patients, CE-TRUS was performed with intravenous injection of contrast agent (SonoVue, 2.4 ml) before biopsy. The cancer detection rates of the two techniques were compared. False-positive and false-negative findings related to CE-TRUS were analyzed in comparison to the pathological results of biopsy or radical prostatectomy. The targeted biopsy to abnormal CE-TRUS areas was also compared to systematic biopsy. Results: Prostate cancer was detected in 29 of the 65 patients. CE-TRUS showed rapid focal enhancement or asymmetric vessels of peripheral zones in 28 patients; 23 of them had prostate cancer. CE-TRUS had 79.3% sensitivity, compared to 65.5% of TRUS (P < 0.05). There were five false-positive and six false-negative findings from CE-TRUS. Benign prostate hyperplasia, and acute and chronic prostatitis were important causes related to the false-positive results of CE-TRUS. Prostate cancer originating from the transition zone or peripheral zone with lower PSA levels, small-size foci, and moderately or well-differentiated tumor was missed by CE-TRUS. The cancer detection rate of targeted biopsy (75%, 33/44 cores) was significantly higher than one of systematic biopsy (48.2%, 162/336) in those 28 cases (P < 0.05). In addition, no significant correlation was found between the cancer detection rate with CE-TRUS and serum PSA levels. Conclusion: CE-TRUS may improve the detection rate of prostate cancer through targeted biopsy of contrast-enhanced abnormalities. Our findings indicate that systematic biopsies should not be eliminated on the basis of false-positive and false-negative findings related to CE-TRUS.

  14. Optimal Admission to Higher Education

    DEFF Research Database (Denmark)

    Albæk, Karsten

    This paper constructs higher education admission rules that maximise graduation rates and thus increase the skill level of the work force. An application shows that students with a low level in mathematics in secondary school ought to find it easier to be admitted to an economics programme than...... to law or psychology programmes, even though economics is the most difficult programme from which to graduate without a strong background in mathematics. Indirect gains from optimal admission include the potential of making whole cohorts of students more able to graduate with a higher education degree....

  15. Apriori-based network intrusion detection system

    International Nuclear Information System (INIS)

    Wang Wenjin; Liu Junrong; Liu Baoxu

    2012-01-01

    With the development of network communication technology, more and more social activities run by Internet. In the meantime, the network information security is getting increasingly serious. Intrusion Detection System (IDS) has greatly improved the general security level of whole network. But there are still many problem exists in current IDS, e.g. high leak rate detection/false alarm rates and feature library need frequently upgrade. This paper presents an association-rule based IDS. This system can detect unknown attack by generate rules from training data. Experiment in last chapter proved the system has great accuracy on unknown attack detection. (authors)

  16. Geographically weighted regression as a generalized Wombling to detect barriers to gene flow.

    Science.gov (United States)

    Diniz-Filho, José Alexandre Felizola; Soares, Thannya Nascimento; de Campos Telles, Mariana Pires

    2016-08-01

    Barriers to gene flow play an important role in structuring populations, especially in human-modified landscapes, and several methods have been proposed to detect such barriers. However, most applications of these methods require a relative large number of individuals or populations distributed in space, connected by vertices from Delaunay or Gabriel networks. Here we show, using both simulated and empirical data, a new application of geographically weighted regression (GWR) to detect such barriers, modeling the genetic variation as a "local" linear function of geographic coordinates (latitude and longitude). In the GWR, standard regression statistics, such as R(2) and slopes, are estimated for each sampling unit and thus are mapped. Peaks in these local statistics are then expected close to the barriers if genetic discontinuities exist, capturing a higher rate of population differentiation among neighboring populations. Isolation-by-Distance simulations on a longitudinally warped lattice revealed that higher local slopes from GWR coincide with the barrier detected with Monmonier algorithm. Even with a relatively small effect of the barrier, the power of local GWR in detecting the east-west barriers was higher than 95 %. We also analyzed empirical data of genetic differentiation among tree populations of Dipteryx alata and Eugenia dysenterica Brazilian Cerrado. GWR was applied to the principal coordinate of the pairwise FST matrix based on microsatellite loci. In both simulated and empirical data, the GWR results were consistent with discontinuities detected by Monmonier algorithm, as well as with previous explanations for the spatial patterns of genetic differentiation for the two species. Our analyses reveal how this new application of GWR can viewed as a generalized Wombling in a continuous space and be a useful approach to detect barriers and discontinuities to gene flow.

  17. Impact of common cytostatic drugs on pollen fertility in higher plants.

    Science.gov (United States)

    Mišík, Miroslav; Kundi, Michael; Pichler, Clemens; Filipic, Metka; Rainer, Bernhard; Mišíková, Katarina; Nersesyan, Armen; Knasmueller, Siegfried

    2016-08-01

    Cytostatic drugs are among the most toxic chemicals which are produced. Many of them cause damage of the genetic material which may affect the fertility of higher organisms. To study the impact of the widely used anticancer drugs [cisplatin (CisPt), etoposide (Et), and 5-fluorouracil (5-FU)] on the reproduction of higher plants, pollen abortion experiments were conducted with species which belong to major plant families, namely with Tradescantia paludosa (Commelinaceae), Arabidopsis thaliana (Brassicaceae), Chelidonium majus (Papaveraceae), and Alisma plantago-aquatica (Alismataceae). All compounds increased the frequencies of abortive grains. The lowest effective doses were in general in a narrow range (i.e., 1 and 10 mg/kg of dry soil). The effects of the individual drugs were similar in T. paludosa, A. plantago-aquatica, and Ch. majus, while A. thaliana was consistently less sensitive. The highest abortion rate was obtained in most experiments with CisPt, followed by 5-FU and Et. Comparisons of the doses which caused effects in the present experiments in the different species with the predicted environment concentrations and with the levels of the cytostatics which were detected in hospital wastewaters show that the realistic environmental concentrations of the drugs are 4-6 orders of magnitude lower. Therefore, it is unlikely that these drugs affect the fertility of higher plants in aquatic and terrestrial ecosystems.

  18. Is the detection rate of 18F-choline PET/CT influenced by androgen-deprivation therapy?

    Energy Technology Data Exchange (ETDEWEB)

    Chondrogiannis, Sotirios; Marzola, Maria Cristina; Grassetto, Gaia; Maffione, Anna Margherita; Rampin, Lucia; Rubello, Domenico [' ' Santa Maria della Misericordia' ' Hospital, Rovigo (Italy). PET/CT Centre; Ferretti, Alice [' ' San Giacomo Apostolo' ' Hospital, Castelfranco Veneto, Treviso (Italy). Service of Medical Physics; Fanti, Stefano [Azienda Ospedaliero-Univ. Policlinico S. Orsola-Malpighi, Bologna (Italy). Dept. of Nuclear Medicine; Giammarile, Francesco [Lyon 1 Univ. Centre Hospitalier Lyon Sud Biophysique, Villeurbanne (Italy). Dept. of Nuclear Medicine

    2014-07-15

    To evaluate if the detection rate (DR) of {sup 18}F-choline (18F-CH) PET/CT is influenced by androgen-deprivation therapy (ADT) in patients with prostate cancer (PC) already treated with radical intent and presenting biochemical relapse. We have retrospectively evaluated {sup 18}F-CH PET/CT scans of 325 consecutive PC patients enrolled in the period November 2009 to December 2012 previously treated with radical intent and referred to our centre to perform {sup 18}F-CH PET/CT for biochemical relapse. Two different groups of patients were evaluated. group A included the whole sample of 325 patients (mean age 70 years, range: 49-86) who presented trigger PSA between 0.1 and 80 ng/ml (mean 5.5 ng/ml), and group B included 187 patients (mean age 70 years, range 49-86) with medium-low levels of trigger PSA ranging between 0.5 and 5 ng/ml (mean PSA 2.1 ng/ml); group B was chosen in order to obtain a more homogeneous group of patients in terms of PSA values also excluding both very low and very high PSA levels avoiding the ''a priori'' higher probability of negative or positive PET scan, respectively. At the time of examination, 139 patients from group A and 72 patients from group B were under ADT: these patients were considered to be hormone-resistant PC patients because from their oncologic history (>18 months) an increase of PSA levels emerged despite the ongoing ADT. The relationship between {sup 18}F-CH PET/CT findings and possible clinical predictors was investigated using both univariate and multivariate binary logistic regression analyses, including trigger PSA and ADT. Considering the whole population, overall DR of {sup 18}F-CH PET was 58.2 % (189/325 patients). In the whole sample of patients (group A), both at the univariate and multivariate logistic regression analysis, trigger PSA and ADT were significantly correlated with the DR of {sup 18}F-CH PET (p < 0.05). Moreover, the DR in patients under ADT (mean PSA 7.8 ng/ml) was higher than in

  19. Occlusion classifiers for picture rate conversion

    NARCIS (Netherlands)

    Bartels, C.L.L.; Haan, de G.; Rabbani, Majid

    2009-01-01

    Occlusion detection is an essential ingredient in high quality picture rate up-conversion and view interpolation applications. Many integrated approaches to occlusion detection and classification have been proposed, particularly in the stereo literature. However, due to their high complexity and

  20. {sup 123}I-MIBG imaging detects cardiac involvement and predicts cardiac events in Churg-Strauss syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Yoriko; Morita, Yukiko [National Hospital Organization Sagamihara National Hospital, Department of Cardiology, Sagamihara City, Kanagawa (Japan); Tsurikisawa, Naomi; Akiyama, Kazuo [National Hospital Organization Sagamihara National Hospital, Clinical Research Centre for Allergy and Rheumatology, Sagamihara City, Kanagawa (Japan)

    2011-02-15

    In Churg-Strauss syndrome (CSS) it is important to detect cardiac involvement, which predicts poor prognosis. This study evaluated whether {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy could detect cardiac damage and predict cardiac events in CSS. {sup 123}I-MIBG scintigraphy was performed in 28 patients with CSS, 12 of whom had cardiac involvement. The early and delayed heart to mediastinum ratio (early H/M and delayed H/M) and washout rate were calculated by using {sup 123}I-MIBG scintigraphy and compared with those in control subjects. Early H/M and delayed H/M were significantly lower and the washout rate was significantly higher in patients with cardiac involvement than in those without and in controls (early H/M, p = 0.0024, p = 0.0001; delayed H/M, p = 0.0002, p = 0.0001; washout rate, p = 0.0012, p = 0.0052 vs those without and vs controls, respectively). Accuracy for detecting cardiac involvement was 86% for delayed H/M and washout rate and 79% for early H/M and B-type natriuretic peptide (BNP). Kaplan-Meier analysis showed significantly lower cardiac event-free rates in patients with early H/M {<=} 2.18 and BNP > 21.8 pg/ml than those with early H/M > 2.18 and BNP {<=} 21.8 pg/ml (log-rank test p = 0.006). Cardiac sympathetic nerve function was damaged in CSS patients with cardiac involvement. {sup 123}I-MIBG scintigraphy was useful in detecting cardiac involvement and in predicting cardiac events. (orig.)