WorldWideScience

Sample records for high-performance liquid chromatography-diode-array

  1. Simultaneous determination of niacin and pyridoxine at trace levels by using diode array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Sel, Sabriye; Öztürk Er, Elif; Bakırdere, Sezgin

    2017-12-01

    A highly sensitive and simple diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method was developed for the simultaneous determination of niacin and pyridoxine in pharmaceutical drugs, tap water, and wastewater samples. To determine the in vivo behavior of niacin and pyridoxine, analytes were subjected to simulated gastric conditions. The calibration plots of the diode-array high-performance liquid chromatography and liquid chromatography with quadrupole time-of-flight tandem mass spectrometry method showed good linearity over a wide concentration range with close to 1.0 correlation coefficients for both analytes. The limit of detection/limit of quantitation values for liquid chromatography quadrupole time-of-flight tandem mass spectrometry analysis were 1.98/6.59 and 1.3/4.4 μg/L for niacin and pyridoxine, respectively, while limit of detection/limit of quantitation values for niacin and pyridoxine in high-performance liquid chromatography analysis were 3.7/12.3 and 5.7/18.9 μg/L, respectively. Recovery studies were also performed to show the applicability of the developed methods, and percentage recovery values were found to be 90-105% in tap water and 94-97% in wastewater for both analytes. The method was also successfully applied for the qualitative and quantitative determination of niacin and pyridoxine in drug samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Integrating qualitative and quantitative characterization of traditional Chinese medicine injection by high-performance liquid chromatography with diode array detection and tandem mass spectrometry.

    Science.gov (United States)

    Xie, Yuan-yuan; Xiao, Xue; Luo, Juan-min; Fu, Chan; Wang, Qiao-wei; Wang, Yi-ming; Liang, Qiong-lin; Luo, Guo-an

    2014-06-01

    The present study aims to describe and exemplify an integrated strategy of the combination of qualitative and quantitative characterization of a multicomponent mixture for the quality control of traditional Chinese medicine injections with the example of Danhong injection (DHI). The standardized chemical profile of DHI has been established based on liquid chromatography with diode array detection. High-performance liquid chromatography coupled with time-of-flight mass spectrometry and high-performance liquid chromatography with electrospray multistage tandem ion-trap mass spectrometry have been developed to identify the major constituents in DHI. The structures of 26 compounds including nucleotides, phenolic acids, and flavonoid glycosides were identified or tentatively characterized. Meanwhile, the simultaneous determination of seven marker constituents, including uridine, adenosine, danshensu, protocatechuic aldehyde, p-coumaric acid, rosmarinic acid, and salvianolic acid B, in DHI was performed by multiwavelength detection based on high-performance liquid chromatography with diode array detection. The integrated qualitative and quantitative characterization strategy provided an effective and reliable pattern for the comprehensive and systematic characterization of the complex traditional Chinese medicine system. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    Science.gov (United States)

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  4. Separation and quantitation of colour pigments of chili powder (Capsicum frutescens) by high-performance liquid chromatography-diode array detection.

    Science.gov (United States)

    Cserháti, T; Forgács, E; Morais, M H; Mota, T; Ramos, A

    2000-10-27

    The performance of reversed-phase thin-layer (RP-TLC) and reversed-phase high-performance liquid chromatography (RP-HPLC) was compared for the separation and determination of the colour pigments of chili (Capsicum frutescens) powder using a wide variety of eluent systems. No separation of pigments was achieved in RP-TLC, however, it was established that tetrahydrofuran shows an unusually high solvent strength. RP-HPLC using water-methanol-acetonitrile gradient elution separated the chili pigments in many fractions. Diode array detection (DAD) indicated that yellow pigments are eluted earlier than the red ones and chili powder contains more yellow pigments than common paprika powders. It was established that the very different absorption spectra of pigments make the use of DAD necessary.

  5. Classification of the medicinal plants of the genus Atractylodes using high-performance liquid chromatography with diode array and tandem mass spectrometry detection combined with multivariate statistical analysis.

    Science.gov (United States)

    Cho, Hyun-Deok; Kim, Unyong; Suh, Joon Hyuk; Eom, Han Young; Kim, Junghyun; Lee, Seul Gi; Choi, Yong Seok; Han, Sang Beom

    2016-04-01

    Analytical methods using high-performance liquid chromatography with diode array and tandem mass spectrometry detection were developed for the discrimination of the rhizomes of four Atractylodes medicinal plants: A. japonica, A. macrocephala, A. chinensis, and A. lancea. A quantitative study was performed, selecting five bioactive components, including atractylenolide I, II, III, eudesma-4(14),7(11)-dien-8-one and atractylodin, on twenty-six Atractylodes samples of various origins. Sample extraction was optimized to sonication with 80% methanol for 40 min at room temperature. High-performance liquid chromatography with diode array detection was established using a C18 column with a water/acetonitrile gradient system at a flow rate of 1.0 mL/min, and the detection wavelength was set at 236 nm. Liquid chromatography with tandem mass spectrometry was applied to certify the reliability of the quantitative results. The developed methods were validated by ensuring specificity, linearity, limit of quantification, accuracy, precision, recovery, robustness, and stability. Results showed that cangzhu contained higher amounts of atractylenolide I and atractylodin than baizhu, and especially atractylodin contents showed the greatest variation between baizhu and cangzhu. Multivariate statistical analysis, such as principal component analysis and hierarchical cluster analysis, were also employed for further classification of the Atractylodes plants. The established method was suitable for quality control of the Atractylodes plants. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. [Simultaneous determination of four compounds in Sanjing Shuanghuanglian Oral Liquid by high performance liquid chromatography-diode array detection-electrochemical detection].

    Science.gov (United States)

    Liu, Lin; Suo, Zhirong; Zheng, Jianbin

    2006-05-01

    Chlorogenic acid, caffeic acid, baicalin and luteolin in Sanjing Shuanghuanglian Oral Liquid were simultaneously detected and identified using a high performance liquid chromatography coupled with diode array detection and electrochemical detection (HPLC-DAD-ECD). The separation was performed on a Zorbax SB-C18 column (150 mm x 4.6 mm i. d., 5.0 microm). The mobile phase consisted of (A) methanol and (B) methanol-water-acetic acid (50: 50: 1, v/v/v) using a linear gradient elution of 2%A-3%A at 0-3 min, 3%A-25%A at 3-15 min, 25%A-80%A at 15-20 min. The flow rate was 0.8 mL/min. The DAD detection was used at 275 nm. The ECD detection was done at 0.7 V. The column thermostat set at 30 degrees C. The limits of detection of the 4 compounds were 1 mg/L for chlorogenic acid, 0.2 mg/L for caffeic acid, 9 mg/L for baicalin, 7 mg/L for luteolin. The average recoveries were between 96.6%-99.6% with relative standard deviations (RSDs) of 2.5%-4.1%. The method is simple, rapid, reproducible and accurate. It can be used for the routine analysis of the four compounds in Shuanghuanglian Oral Liquid.

  7. Quantification of maltol in Korean ginseng (Panax ginseng) products by high-performance liquid chromatography-diode array detector

    Science.gov (United States)

    Jeong, Hyun Cheol; Hong, Hee-Do; Kim, Young-Chan; Rhee, Young Kyoung; Choi, Sang Yoon; Kim, Kyung-Tack; Kim, Sung Soo; Lee, Young-Chul; Cho, Chang-Won

    2015-01-01

    Background: Maltol, as a type of phenolic compounds, is produced by the browning reaction during the high-temperature treatment of ginseng. Thus, maltol can be used as a marker for the quality control of various ginseng products manufactured by high-temperature treatment including red ginseng. For the quantification of maltol in Korean ginseng products, an effective high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed. Materials and Methods: The HPLC-DAD method for maltol quantification coupled with a liquid-liquid extraction (LLE) method was developed and validated in terms of linearity, precision, and accuracy. An HPLC separation was performed on a C18 column. Results: The LLE methods and HPLC running conditions for maltol quantification were optimized. The calibration curve of the maltol exhibited good linearity (R2 = 1.00). The limit of detection value of maltol was 0.26 μg/mL, and the limit of quantification value was 0.79 μg/mL. The relative standard deviations (RSDs) of the data of the intra- and inter-day experiments were <1.27% and 0.61%, respectively. The results of the recovery test were 101.35–101.75% with an RSD value of 0.21–1.65%. The developed method was applied successfully to quantify the maltol in three ginseng products manufactured by different methods. Conclusion: The results of validation demonstrated that the proposed HPLC-DAD method was useful for the quantification of maltol in various ginseng products. PMID:26246746

  8. Simultaneous Detection of Sulfamethoxazole, Diclofenac, Carbamazepine, and Bezafibrate by Solid Phase Extraction and High Performance Liquid Chromatography with Diode Array Detection

    Science.gov (United States)

    Zhou, Z.; Jiang, J.-Q.

    2014-05-01

    A method of solid phase extraction (SPE) coupled with high performance liquid chromatography and diode array detection (HPLC-DAD) was studied for the simultaneous determination of sulfamethoxazole (SMX), diclofenac (DCF), carbamazepine (CBZ), and bezafi brate (BZF) in test solutions. The target compounds were extracted by SPE from samples, and the resulting elutes were analyzed using a HPLC-DAD system at wavelengths of 270, 280, 290, and 230 nm for SMX, DCF, CBZ, and BZF, respectively. This method shows good recoveries for SMX, DCF, CBZ, and BZF with mean recoveries of 89.7 ± 9.3%, 86.1 ± 7.6%, 95.0 ± 6.5%, and 94.0 ± 5.4%, respectively.

  9. Rapid quantitative analysis of individual anthocyanin content based on high-performance liquid chromatography with diode array detection with the pH differential method.

    Science.gov (United States)

    Wang, Huayin

    2014-09-01

    A new quantitative technique for the simultaneous quantification of the individual anthocyanins based on the pH differential method and high-performance liquid chromatography with diode array detection is proposed in this paper. The six individual anthocyanins (cyanidin 3-glucoside, cyanidin 3-rutinoside, petunidin 3-glucoside, petunidin 3-rutinoside, and malvidin 3-rutinoside) from mulberry (Morus rubra) and Liriope platyphylla were used for demonstration and validation. The elution of anthocyanins was performed using a C18 column with stepwise gradient elution and individual anthocyanins were identified by high-performance liquid chromatography with tandem mass spectrometry. Based on the pH differential method, the high-performance liquid chromatography peak areas of maximum and reference absorption wavelengths of anthocyanin extracts were conducted to quantify individual anthocyanins. The calibration curves for these anthocyanins were linear within the range of 10-5500 mg/L. The correlation coefficients (r(2)) all exceeded 0.9972, and the limits of detection were in the range of 1-4 mg/L at a signal-to-noise ratio ≥5 for these anthocyanins. The proposed quantitative analysis was reproducible with good accuracy of all individual anthocyanins ranging from 96.3 to 104.2% and relative recoveries were in the range 98.4-103.2%. The proposed technique is performed without anthocyanin standards and is a simple, rapid, accurate, and economical method to determine individual anthocyanin contents. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Simultaneous determination of six synthetic phenolic antioxidants in edible oils using dispersive liquid-liquid microextraction followed by high-performance liquid chromatography with diode array detection.

    Science.gov (United States)

    Xu, Shuangjiao; Liu, Liangliang; Wang, Yanqin; Zhou, Dayun; Kuang, Meng; Fang, Dan; Yang, Weihua; Wei, Shoujun; Xiao, Aiping; Ma, Lei

    2016-08-01

    A simple, rapid, organic-solvent- and sample-saving pretreatment technique, called dispersive liquid-liquid microextraction, was developed for the determination of six synthetic phenolic antioxidants from edible oils before high-performance liquid chromatography with diode array detection. The entire procedure was composed of a two-step microextraction and a centrifugal process and could be finished in about 5 min, only consuming only 25 mg of sample and 1 mL of the organic solvent for each extraction. The influences of several important parameters on the microextraction efficiency were thoroughly investigated. Recovery assays for oil samples were spiked at three concentration levels, 50, 100 and 200 mg/kg, and provided recoveries in the 86.3-102.5% range with a relative standard deviation below 3.5%. The intra-day and inter-day precisions for the analysis were less than 3.8%. The proposed method was successfully applied for the determination of synthetic phenolic antioxidants in different oil samples, and satisfactory results were obtained. Thus, the developed method represents a viable alternative for the quality control of synthetic phenolic antioxidant concentrations in edible oils. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma.

    Science.gov (United States)

    Kopec, Rachel E; Schweiggert, Ralf M; Riedl, Ken M; Carle, Reinhold; Schwartz, Steven J

    2013-06-30

    Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal

  12. Characterisation of acid dyes in forensic fibre analysis by high-performance liquid chromatography using narrow-bore columns and diode array detection.

    Science.gov (United States)

    Laing, D K; Gill, R; Blacklaws, C; Bickley, H M

    1988-06-17

    A gradient elution high-performance liquid chromatographic (HPLC) system with a diode array detector and a short narrow-bore (40 x 1 mm I.D.) column has been used to characterise a number of acid dyes. The resolution and reproducibility of the HPLC system have been evaluated and the detection limits for various dyes have been estimated. Comparisons are made with current methods of fibre dyestuff examination used in forensic science. The system has been applied to the analysis of dye extracted from single fibres. Using diode array detection, both chromatographic and spectral data can be produced in a single operation from casework sized samples.

  13. Chemical analysis of raw and processed Fructus arctii by high-performance liquid chromatography/diode array detection-electrospray ionization-mass spectrometry

    Science.gov (United States)

    Qin, Kunming; Liu, Qidi; Cai, Hao; Cao, Gang; Lu, Tulin; Shen, Baojia; Shu, Yachun; Cai, Baochang

    2014-01-01

    Background: In traditional Chinese medicine (TCM), raw and processed herbs are used to treat the different diseases. Fructus Arctii, the dried fruits of Arctium lappa l. (Compositae), is widely used in the TCM. Stir-frying is the most common processing method, which might modify the chemical compositions in Fructus Arctii. Materials and Methods: To test this hypothesis, we focused on analysis and identification of the main chemical constituents in raw and processed Fructus Arctii (PFA) by high-performance liquid chromatography/diode array detection-electrospray ionization-mass spectrometry. Results: The results indicated that there was less arctiin in stir-fried materials than in raw materials. however, there were higher levels of arctigenin in stir-fried materials than in raw materials. Conclusion: We suggest that arctiin reduced significantly following the thermal conversion of arctiin to arctigenin. In conclusion, this finding may shed some light on understanding the differences in the therapeutic values of raw versus PFA in TCM. PMID:25422559

  14. Simultaneous and rapid determination of deoxynivalenol and its acetylate derivatives in wheat flour and rice by ultra high performance liquid chromatography with photo diode array detection.

    Science.gov (United States)

    Xu, Jiao-Jiao; Zhou, Jian; Huang, Bai-Fen; Cai, Zeng-Xuan; Xu, Xiao-Min; Ren, Yi-Ping

    2016-06-01

    A simple and reliable method of ultra high performance liquid chromatography coupled with photo-diode array detection has been proposed for the simultaneous determination of deoxynivalenol and its acetylated derivatives in wheat flour and rice, especially focusing on the optimization of sample extraction, cleanup, and chromatographic separation conditions. Sample pretreatment consisted of a first step using a quick, easy, cheap, effective, rugged, and safe based extraction procedure and a subsequent cleanup step based on solid-phase extraction. The method was extensively validated in wheat flour and rice, obtaining satisfactory analytical performance with good linearity (R(2) ≥ 0.999), acceptable recoveries (80.0-104.4%), and repeatability (RSDs 1.3-10.7%). The limits of detection (21.7-57.4 μg/kg) and quantitation (72.3-191.4 μg/kg) for deoxynivalenols were lower than those usually permitted by various countries' legislation in these food matrices. The method was applied to 34 wheat and rice samples. The results were further compared with results of ultra high performance liquid chromatography with electrospray ionization tandem mass spectrometry. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Determination of benzimidazole residues and their metabolites in raw milk using high performance liquid chromatography-diode array detection

    Directory of Open Access Journals (Sweden)

    Marija Denžić Lugomer

    2017-01-01

    Full Text Available A new analytical method using high performance liquid chromatography-diode array detector (HPLC-DAD was developed for the analysis of 18 benzimidazoles and their metabolites in milk. Samples were extracted with acetonitrile and n-hexane and purified by polymer cation exchange (PCX solid phase extraction cartridges. LC separation was performed on Xbridge C18 with gradient elution using acetonitrile and ammonium acetate buffer. The DAD detection was set at 298, 312, 254 and 290 nm. The method was validated according to the criteria of Commission Decision 2002/657/EC. The following validation parameters were set: accuracy (expressed as recovery 31.7-137.6 %, limit of decision (CCα 6.0-120.6 μg kg-1, detection capability (CCβ 6.1-120.8 μg kg-1, limit of detection (LOD 1-4 μg kg-1, limit of quantification (LOQ 4-18 μg kg-1, precision as CV 7.0-22.5 %, withinlaboratory reproducibility expressed as CV 8.8-30.6 %. Finally, the developed method was applied to the analysis of collected milk samples. A total of 50 milk samples was analysed for benzimidazole residues. All obtained concentrations for all compounds were below the LOQ values.

  16. Differentiation of Herba Cistanches by fingerprint with high-performance liquid chromatography-diode array detection-mass spectrometry.

    Science.gov (United States)

    Jiang, Y; Li, S P; Wang, Y T; Chen, X J; Tu, P F

    2009-03-13

    Herba Cistanche (Rou Cong Rong in Chinese), dried succulent stems of Cistanche deserticola or C. tubulosa, is a famous Chinese herbal medicine and has been recorded in the Chinese Pharmacopoeia. In recent years, another two non-official species, C. salsa and C. sinensis have also been used as Herba Cistanche in some regions of China. To investigate the possibility of using these two non-official species as alternatives to the official species, a high-performance liquid chromatography-diode array detection-mass spectrometry (HPLC-DAD-MS) fingerprint method was developed to comparatively analyze the crude herbs of these four species. The fingerprint of C. deserticola, a historically certified species of Herba Cistanche, serves as 'standard pattern' for comparing the similarities with the other species by means of similarity and Principle Component Analysis. Additionally, 18 characteristic peaks in the fingerprints were identified by comparing their retention times, UV spectra and ESI-MS data with those of the reference substances and/or the data in the literatures. The comparative results demonstrate that the fingerprints of C. tubulosa and C. salsa possess high similarity to the standard pattern, suggesting that these two species may be used as alternative species; while that of C. sinensis has low similarity (0.053 correlation coefficient) to the standard pattern, indicating that it cannot be used as the substitute of the official herb. However, the varying fingerprint patterns among the samples of C. deserticola collected from various habitats illustrate that the quality consistency of crude herbs is still a problem worthy of serious concern.

  17. Simultaneous quantification of eight organic acid components in Artemisia capillaris Thunb (Yinchen extract using high-performance liquid chromatography coupled with diode array detection and high-resolution mass spectrometry

    Directory of Open Access Journals (Sweden)

    Fangjun Yu

    2018-04-01

    Full Text Available We aim to determine the chemical constituents of Yinchen extract and Yinchen herbs using high-performance liquid chromatography coupled with diode array detection and high-resolution mass spectrometry. The method was developed to analyze of eight organic acid components of Yinchen extract (including neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, caffeic acid, 1,3-dicaffeoylquinic acid, 3,4-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid and 4,5-dicaffeoylquinic acid. The separation was conducted using an Agilent TC-C18 column with acetonitrile – 0.2% formic acid solution as the mobile phases under gradient elution. The analytical method was fully validated in terms of linearity, sensitivity, precision, repeatability as well as recovery, and subsequently the method was performed for the quantitative assessment of Yinchen extracts and Yinchen herbs. In addition, the changes of selected markers were studied when Yinchen herbs decocting in water and isomerization occurred between the chlorogenic acids. The proposed method enables both qualitative and quantitative analyses and could be developed as a new tool for the quality evaluation of Yinchen extract and Yinchen herbs. The changes of selected markers in water decoction process could give us some novel idea when studying the link between substances and drug efficacy. Keywords: Artemisia capillaris Thunb (Yinchen extract, Quality control, Organic acid, Transformation pathways, High-performance liquid chromatography

  18. Determination of Carotenoids in Human Serum and Breast Milk Using High Performance Liquid Chromatography Coupled with a Diode Array Detector (HPLC-DAD

    Directory of Open Access Journals (Sweden)

    Jing Tan

    2017-05-01

    Full Text Available High performance liquid chromatography (HPLC coupled with a diode array detector (HPLC-DAD for the identification and quantification of carotenoids, namely all-trans lutein, zeaxanthin, β-cryptoxanthin, α-carotene, and β-carotene, in biological samples such as human serum and breast milk, has been developed and validated. Good chromatography separation was achieved using a binary mobile phase system on a YMC C30 column (150 × 2.1 mm, 3 µm at 30 °C. Owing to the smaller column particle size and diameter of the column, the separation was achieved in 18 min, which is significantly reduced from the typical 30–40 min of other methods. The diode array detector (DAD acquisition was set at a wavelength of 445 nm; 3D spectra ranging from wavelengths of 240–600 nm were also recorded. Peaks were identified by matching their retention time and spectra with those of standards. Quantification was achieved by internal standard calibration using echinenone as the internal standard. Good linearity was obtained for each compound (R2 > 0.9999. The method quantification limits (MQLs for serum and breast milk were 10 ng/mL and 5 ng/mL, in matrix, respectively. A spike recovery study and standard reference material (SRM from the National Institute of Standards and Technology (NIST 968e analysis has proven that the method has a high degree of accuracy, precision, and robustness. The stability study showed that the carotenoid standard and sample extracts could be stored in a chilled autosampler at 8 °C up to 48 h without being comprised, which provides guidance on re-test time frames. The freeze/thaw process was found to be detrimental to carotenoids, and should always be avoided. Most importantly, UV standardization of the stock standard is to be performed prior to each assay, and simply taking the values on Certificate of Analysis (CoA for calculation of the standard concentration is not recommended.

  19. Isolation and identification of phenolic compounds from rum aged in oak barrels by high-speed countercurrent chromatography/high-performance liquid chromatography-diode array detection-electrospray ionization mass spectrometry and screening for antioxidant activity.

    Science.gov (United States)

    Regalado, Erik L; Tolle, Sebastian; Pino, Jorge A; Winterhalter, Peter; Menendez, Roberto; Morales, Ana R; Rodríguez, José L

    2011-10-14

    Beverages, especially wines are well-known to contain a variety of health-beneficial bioactive substances, mainly of phenolic nature which frequently exhibit antioxidant activity. Significant information is available about the separation and identification of polyphenols from some beverages by chromatographic and spectroscopic techniques, but considerably poor is chemical data related to the polyphenolic content in rums. In this paper, a method involving the all-liquid chromatographic technique of high-speed countercurrent chromatography (HSCCC) combined with high-performance liquid chromatography coupled with diode-array detection and electrospray ionization mass spectrometry (HPLC-DAD-ESI-MS(n)) has been successfully applied for separation and identification of phenolic compounds in an aged rum. Besides, the phenolic fraction (PF) was assayed for its antioxidant effects using three different free radical in vitro assays (DPPH·, RO(2)· and spontaneous lipid peroxidation (LPO) on brain homogenates) and on ferric reducing antioxidant power (FRAP). Results showed that PF potently scavenged DPPH and strongly scavenged peroxyl radicals compared to ascorbic acid and butylated hydroxytoluene (BHT); and almost equally inhibited LPO on brain homogenates subjected to spontaneous LPO when compared to quercetin. Moreover, PF also exhibited strong reducing power. This chemical analysis illustrates the rich array of phenols in the aged rum and represents a rapid and suitable method for the isolation and identification of phenolic compounds from mixtures of considerable complexity, achieving high purity and reproducibility with the use of two separation steps. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Quality evaluation of moluodan concentrated pill using high-performance liquid chromatography fingerprinting coupled with chemometrics.

    Science.gov (United States)

    Tao, Lingyan; Zhang, Qing; Wu, Yongjiang; Liu, Xuesong

    2016-12-01

    In this study, a fast and effective high-performance liquid chromatography method was developed to obtain a fingerprint chromatogram and quantitative analysis simultaneously of four indexes including gallic acid, chlorogenic acid, albiflorin and paeoniflorin of the traditional Chinese medicine Moluodan Concentrated Pill. The method was performed by using a Waters X-bridge C 18 reversed phase column on an Agilent 1200S high-performance liquid chromatography system coupled with diode array detection. The mobile phase of the high-performance liquid chromatography method was composed of 20 mmol/L phosphate solution and acetonitrile with a 1 mL/min eluent velocity, under a detection temperature of 30°C and a UV detection wavelength of 254 nm. After the methodology validation, 16 batches of Moluodan Concentrated Pill were analyzed by this high-performance liquid chromatography method and both qualitative and quantitative evaluation results were achieved by similarity analysis, principal component analysis and hierarchical cluster analysis. The results of these three chemometrics were in good agreement and all indicated that batch 10 and batch 16 showed significant differences with the other 14 batches. This suggested that the developed high-performance liquid chromatography method could be applied in the quality evaluation of Moluodan Concentrated Pill. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Evaluating the Antibacterial Properties of Polyacetylene and Glucosinolate Compounds with Further Identification of Their Presence within Various Carrot (Daucus carota) and Broccoli (Brassica oleracea) Cultivars Using High-Performance Liquid Chromatography with a Diode Array Detector and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry Analyses.

    Science.gov (United States)

    Hinds, L; Kenny, O; Hossain, M B; Walsh, D; Sheehy, E; Evans, P; Gaffney, M; Rai, D K

    2017-08-23

    Ongoing consumer concerns over using synthetic additives in foods has strongly influenced efforts worldwide to source suitable natural alternatives. In this study, the antibacterial efficacy of polyacetylene and glucosinolate compounds was evaluated against both Gram positive and Gram negative bacterial strains. Falcarinol [minimum inhibitory concentration (MIC) = 18.8-37.6 μg/mL] demonstrated the best overall antibacterial activity, while sinigrin (MIC = 46.9-62.5 μg/mL) was the most active glucosinolate compound. High-performance liquid chromatography with a diode array detector analysis showed falcarinol [85.13-244.85 μg/g of dry weight (DW)] to be the most abundant polyacetylene within six of the eight carrot (Daucus carota) cultivars investigated. Meanwhile, sinigrin (100.2-244.3 μg/g of DW) was the most abundant glucosinolate present within the majority of broccoli (Brassica oleracea) cultivars investigated using ultra performance liquid chromatography-tandem mass spectrometry analysis. The high abundance of both falcarinol and sinigrin within these respective species suggests that they could serve as potential sources of natural antibacterial agents for use as such in food products.

  2. IDENTIFIKASI ANTOSIANIN BUAH DUWET (Syzygium cumini MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI - DIODE ARRAY DETECTION [Identification of Anthocyanins in Jambolan Fruit (Syzygium cumini by High Performance Liquid Chromatography - Diode Array Detection

    Directory of Open Access Journals (Sweden)

    Puspita Sari1*

    2009-12-01

    Full Text Available The aim of this study was to determine the content of total monomeric anthocyanins and to identify the anthocyanin composition of jambolan fruit (Syzygium cumini growing in Indonesia. Anthocyanins were extracted with methanol containing 0.1% HCl, removed from non-polar impurities by partition with chloroform and purified in a C18 solid phase cartridge. Anthocyanins were identified by high-performance liquid chromatography with diode array detection (HPLC-DAD, UV-visible spectral analysis, and physico-chemical reactions. Using pH-differential method, it was known that the content of total monomeric anthocyanin in the ripe fruit was 161 mg/100 g fresh fruit (731 mg/100 g skin on wet basis or 3430 mg/100 g skin on dry basis, based on cyanidin-3-glucoside. Furthermore, five anthocyanins without acylating groups were identified as 3,5-diglucoside derivatives of delphinidin (41.29%, petunidin (27.79%, malvidin (25.60%, cyanidin (4.19%, and peonidin (1.13%. These results demonstrate that the skin of jambolan fruit especially the ripe one is rich in anthocyanin, with wide range in anthocyanidin backbone (five aglycons.

  3. Qualitative and quantitative two-dimensional thin-layer chromatography/high performance liquid chromatography/diode-array/electrospray-ionization-time-of-flight mass spectrometry of cholinesterase inhibitors.

    Science.gov (United States)

    Mroczek, Tomasz

    2016-09-10

    Recently launched thin-layer chromatography-mass spectrometry (TLC-MS) interface enabling extraction of compounds directly from TLC plates into MS ion source was unusually extended into two-dimensional thin-layer chromatography/high performance liquid chromatography (2D, TLC/HPLC) system by its a direct connection to a rapid resolution 50×2.1mm, I.D. C18 column compartment followed by detection by diode array (DAD) and electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS). In this way, even not separated bands of complicated mixtures of natural compounds could be analysed structurally, only within 1-2min after development of TLC plates. In comparison to typically applied TLC-MS interface, no ion suppression for acidic mobile phases was observed. Also, substantial increase in ESI-TOF-MS sensitivities and quality of spectra, were noticed. It has been utilised in combination with TLC- based bioautographic approaches of acetylcholinesterase (AChE) inhibitors, However, it can be also applied in any other procedures related to bioactivity (e.g. 2,2-Diphenyl-1-picryl-hydrazyl-DPPH screen test for radicals). This system has been also used for determination of half maximal inhibitory concentration (IC50 values) of the active inhibitor-galanthamine, as an example. Moreover, AChE inhibitory potencies of some of purified plant extracts, never studied before, have been quantitatively measured. This is first report of usage such the 2D TLC/HPLC/MS system both for qualitative and quantitative evaluation of cholinesterase inhibitors in biological matrices. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A validated high-performance liquid chromatography method with diode array detection for simultaneous determination of nine flavonoids in Senecio cannabifolius Less.

    Science.gov (United States)

    Niu, Tian-Zeng; Zhang, Yu-Wei; Bao, Yong-Li; Wu, Yin; Yu, Chun-Lei; Sun, Lu-Guo; Yi, Jing-Wen; Huang, Yan-Xin; Li, Yu-Xin

    2013-03-25

    A reversed phase high performance liquid chromatography method coupled with a diode array detector (HPLC-DAD) was developed for the first time for the simultaneous determination of 9 flavonoids in Senecio cannabifolius, a traditional Chinese medicinal herb. Agilent Zorbax SB-C18 column was used at room temperature and the mobile phase was a mixture of acetonitrile and 0.5% formic acid (v/v) in water in the gradient elution mode at a flow-rate of 1.0mlmin(-1), detected at 360nm. Validation of this method was performed to verify the linearity, precision, limits of detection and quantification, intra- and inter-day variabilities, reproducibility and recovery. The calibration curves showed good linearities (R(2)>0.9995) within the test ranges. The relative standard deviation (RSD) of the method was less than 3.0% for intra- and inter-day assays. The samples were stable for at least 96h, and the average recoveries were between 90.6% and 102.5%. High sensitivity was demonstrated with detection limits of 0.028-0.085μg/ml for flavonoids. The newly established HPLC method represents a powerful technique for the quality assurance of S. cannabifolius. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Simultaneous Determination of Four Compounds, Campesterol, Emodin8-O-β-D-Glucopyranoside, Quercetin, and Isoquercitrin in Reynoutria sachalinensis by High-performance Liquid Chromatography-Diode Array Detector

    Science.gov (United States)

    Eom, Min Rye; Weon, Jin Bae; Jung, Youn Sik; Ryu, Ga Hee; Yang, Woo Seung; Ma, Choong Je

    2017-01-01

    Background: Reynoutria sachalinensis is a well-known and used herbal medicine to treatment of arthralgia, jaundice, amenorrhea, coughs, carbuncles, and sores. Objective: We have developed high-performance liquid chromatography analysis method for simultaneous determination of isolated four compounds, campesterol, emodin8-O-β-D-glucopyranoside, quercetin, and isoquercitrin from R. sachalinensis is. Materials and Methods: The four compounds were separated on Shiseido C18 column (S-5 μm, 4.6 mm I.D. ×250 mm) at a column temperature of 25°C. The mobile phase composed of water and methanol with gradient elution system, and flow rate is 1.0 ml/min. The detection wavelength was set at 205 nm. Results: Validation of this analytical method was evaluated by linearity, precision, and accuracy test. This established method had good linearity (R2 > 0.997). The relative standard deviation values of intra- and inter-day testing were indicated that <2%, and accuracy is 91.66%–103.31% at intraday and 91.69%–103.31% at intraday. The results of recovery test were 92.60%–108.99%. Conclusion: In these results, developed method was accurate and reliable to the quality evaluation of campesterol, emodin 8-O-β-D-glucopyranoside, quercetin, and isoquercitrin isolated from R. sachalinensis. SUMMARY We have developed high-performance liquid analysis method for simultaneous determination of 4 compounds of Reynoutria sachalinensis. Abbreviations used: HPLC: High-performance liquid chromatography, DAD: Diode array detector, LOD: Limit of detection, LOQ: Limit of quantitation, ICH: International Conference on Harmonisation. PMID:28808389

  6. Simultaneous determination of atorvastatin and valsartan in human plasma by solid-based disperser liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Khorram, Parisa; Pazhohan, Azar

    2016-04-01

    A simple, sensitive, and efficient method has been developed for simultaneous estimation of valsartan and atorvastatin in human plasma by combination of solid-based dispersive liquid-liquid microextraction and high performance liquid chromatography-diode array detection. In the proposed method, 1,2-dibromoethane (extraction solvent) is added on a sugar cube (as a solid disperser) and it is introduced into plasma sample containing the analytes. After manual shaking and centrifugation, the resultant sedimented phase is subjected to back extraction into a small volume of sodium hydrogen carbonate solution using air-assisted liquid-liquid microextraction. Then the cloudy solution is centrifuged and the obtained aqueous phase is transferred into a microtube and analyzed by the separation system. Under the optimal conditions, extraction recoveries are obtained in the range of 81-90%. Calibration curves plotted in drug-free plasma sample are linear in the ranges of 5-5000μgL(-1) for valsartan and 10-5000μgL(-1) for atorvastatin with the coefficients of determination higher than 0.997. Limits of detection and quantification of the studied analytes in plasma sample are 0.30-2.6 and 1.0-8.2μgL(-1), respectively. Intra-day (n=6) and inter-days (n=4) precisions of the method are satisfactory with relative standard deviations less than 7.4% (at three levels of 10, 500, and 2000μgL(-1), each analyte). These data suggest that the method can be successfully applied to determine trace amounts of valsartan and atorvastatin in human plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. High-speed counter-current chromatography coupled online to high performance liquid chromatography-diode array detector-mass spectrometry for purification, analysis and identification of target compounds from natural products.

    Science.gov (United States)

    Liang, Xuejuan; Zhang, Yuping; Chen, Wei; Cai, Ping; Zhang, Shuihan; Chen, Xiaoqin; Shi, Shuyun

    2015-03-13

    A challenge in coupling high-speed counter-current chromatography (HSCCC) online with high performance liquid chromatography (HPLC) for purity analysis was their time incompatibility. Consequently, HSCCC-HPLC was conducted by either controlling HPLC analysis time and HSCCC flow rate or using stop-and-go scheme. For natural products containing compounds with a wide range of polarities, the former would optimize experimental conditions, while the latter required more time. Here, a novel HSCCC-HPLC-diode array detector-mass spectrometry (HSCCC-HPLC-DAD-MS) was developed for undisrupted purification, analysis and identification of multi-compounds from natural products. Two six-port injection valves and a six-port switching valve were used as interface for collecting key HSCCC effluents alternatively for HPLC-DAD-MS analysis and identification. The ethyl acetate extract of Malus doumeri was performed on the hyphenated system to verify its efficacy. Five main flavonoids, 3-hydroxyphloridzin (1), phloridzin (2), 4',6'-dihydroxyhydrochalcone-2'-O-β-D-glucopyranoside (3, first found in M. doumeri), phloretin (4), and chrysin (5), were purified with purities over 99% by extrusion elution and/or stepwise elution mode in two-step HSCCC, and 25mM ammonium acetate solution was selected instead of water to depress emulsification in the first HSCCC. The online system shortened manipulation time largely compared with off-line analysis procedure and stop-and-go scheme. The results indicated that the present method could serve as a simple, rapid and effective way to achieve target compounds with high purity from natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The offline combination of thin-layer chromatography and high-performance liquid chromatography with diode array detection and micrOTOF-Q mass spectrometry for the separation and identification of spinochromes from sea urchin (Strongylocentrotus droebachiensis) shells.

    Science.gov (United States)

    Shikov, Alexander N; Ossipov, Vladimir I; Martiskainen, Olli; Pozharitskaya, Olga N; Ivanova, Svetlana A; Makarov, Valery G

    2011-12-16

    Thin-layer chromatography (TLC) with off-line high-performance liquid chromatography coupled to diode array detection and micrOTOF-Q mass spectrometry (HPLC-DAD-MS) resulted in the successful fractionation, separation and identification of spinochrome pigments from sea urchin (Strongylocentrotus droebachiensis) shells. Two fractions of pigments were separated by TLC and eluted with methanol using a TLC-MS interface. HPLC-DAD-MS analysis of the fractions indicated the presence of six sea urchin pigments: spinochrome monomers B and D, three spinochrome dimers (anhydroethylidene-6,6'-bis(2,3,7-trihydroxynaphthazarin) and its isomer and ethylidene-6,6'-bis(2,3,7-trihydroxynaphthazarin)), and one pigment that was preliminary identified as a spinochrome dimer with the structural formula C(22)H(16)O(16). Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Quality evaluation of mycelial Antrodia camphorata using high-performance liquid chromatography (HPLC coupled with diode array detector and mass spectrometry (DAD-MS

    Directory of Open Access Journals (Sweden)

    Leung Kelvin

    2010-01-01

    Full Text Available Abstract Background Antrodia camphorata (AC is an important fungus native to Taiwanese forested regions. Scientific studies have demonstrated that extracts of AC possess a variety of pharmacological functions. This study aims to identify the full profile fingerprint of nucleosides and nucleobases in mycelial AC and to assess the quality of two commercial mycelial AC products. Methods High-performance liquid chromatography coupled with diode array detector and mass spectrometry was employed to identify the major components in mycelial AC. The chemical separation was carried out using a gradient program on a reverse phase Alltima C18 AQ analytical column (250 × 4.6 mm, 5 μm with the mobile phase consisting of deionized water and methanol. Results Ten nucleosides and nucleobases, two maleimide derivatives, and a sterol were identified as the major constituents in mycelial AC. These groups of chemical compounds constitute the first chromatographic fingerprint as an index for quality assessment of this medicinal fungus. Conclusions This study provides the first chromatographic fingerprint to assess the quality of mycelial AC.

  10. Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector

    Science.gov (United States)

    Lee, Jiwoo; Weon, Jin Bae; Yun, Bo-Ra; Eom, Min Rye; Ma, Choong Je

    2015-01-01

    Background: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. Objective: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. Materials and Methods: The analytes were separated on a Shiseido C18 column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. Results: Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R2 > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%. Conclusion: The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea. PMID:25829768

  11. Gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection for dating of paper ink.

    Science.gov (United States)

    Díaz-Santana, Oscar; Vega-Moreno, Daura; Conde-Hardisson, Francisco

    2017-09-15

    An extraction and determination method is shown for the analysis of dyes and solvents present in two types of ballpoint pen inks that are deposited onto paper. Ink extracts are analysed using a combination of gas chromatography with mass spectrometry (GC-MS), and high-pressure liquid chromatography with photodiode array detection (HPLC-DAD), within a single sample extraction procedure. Seventeen solvents and thirteen dyes contained in two Montblanc ® inks (black and blue) were monitored for 45 months at monthly intervals, in order to determine variations in the concentrations of the compounds over time. We also studied the relative variations between different compounds and the generation of degradation products such as phenol. The concentration data obtained from these compounds during their exposure have been analysed and a multiple regression model is developed for each ink type that allows an estimate of the exposure time of the ink on paper with a maximum error of between 4 and 7 months. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Identification of protein binders in works of art by high-performance liquid chromatography-diode array detector analysis of their tryptic digests.

    Science.gov (United States)

    Fremout, Wim; Sanyova, Jana; Saverwyns, Steven; Vandenabeele, Peter; Moens, Luc

    2009-04-01

    Proteins in works of art are generally determined by the relative amounts of amino acids. This method, however, implies a loss of information on the protein structure and its modifications. Consequently, we propose a method based on the analysis of trypsin digests using high-performance liquid chromatography (HPLC) UV diode array detection (DAD) for painting binder studies. All reaction steps are done in the same vial; no extraction methods or sample transfer is needed, reducing the risk of sample losses. A collection of pure binders (collagen, ovalbumin, yolk and casein) as well as homemade and historical paint samples have been investigated with this method. Chromatograms of unknowns at 214 nm and 280 nm are compared with those of the reference samples as a fingerprint. There is a good agreement between many peptides, but others seem to have been lost or their retention time shifted due to small compositional changes because of ageing and degradation of the paint. The results are comparable with the results of other techniques used for binder identification on the same samples, with the additional advantage of differentiation between egg yolk and glair.

  13. Simultaneous quantification of coumarins, flavonoids and limonoids in Fructus Citri Sarcodactylis by high performance liquid chromatography coupled with diode array detector.

    Science.gov (United States)

    Chu, Jun; Li, Song-Lin; Yin, Zhi-Qi; Ye, Wen-Cai; Zhang, Qing-Wen

    2012-07-01

    A high performance liquid chromatography coupled with diode array detector (HPLC-DAD) method was developed for simultaneous quantification of eleven major bioactive components including six coumarins, three flavonoids and two limonoids in Fructus Citri Sarcodactylis. The analysis was performed on a Cosmosil 5 C(18)-MS-II column (4.6 mm × 250 mm, 5 μm) with water-acetonitrile gradient elution. The method was validated in terms of linearity, sensitivity, precision, stability and accuracy. It was found that the calibration curves for all analytes showed good linearity (R(2)>0.9993) within the test ranges. The overall limit of detection (LOD) and limit of quantification (LOQ) were less than 3.0 and 10.2 ng. The relative standard deviations (RSDs) for intra- and inter-day repeatability were not more than 4.99% and 4.92%, respectively. The sample was stable for at least 48 h. The spike recoveries of eleven components were 95.1-104.9%. The established method was successfully applied to determine eleven components in three samples from different locations. The results showed that the newly developed HPLC-DAD method was linear, sensitive, precise and accurate, and could be used for quality control of Fructus Citri Sarcodactylis. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Simultaneous Determination of Eight Bioactive Compounds in Dianthus superbus by High-performance Liquid Chromatography.

    Science.gov (United States)

    Yun, Bo-Ra; Yang, Hye Jin; Weon, Jin Bae; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2016-05-01

    Dianthus superbus, one of traditional herbal medicine, is widely used to treat urethritis, carbuncles and carcinoma. A simultaneous determination method was established for controlling the quality of D. superbus using the eight compounds, (E)-methyl-4-hydroxy-4-(8a-methyl-3-oxodecahydronaphthalen-4a-yl) (1), diosmetin-7-O(2'',6''-di-O-α-L-rhamnopyranosyl)-β-D-glucopyranoside (2), vanillic acid (3), 4-hydroxyphenyl acetic acid (4), 4-methoxyphenyl acetic acid (5), (E)-4-methoxycinnamic acid (6), 3-methoxy-4-hydroxyphenylethanol (7), and methyl hydroferulate (8) isolated from D. superbus. This analysis method was developed using high performance liquid chromatography coupled with diode array detector with a Shishedo C18 column at a column temperature of 3°C. The mobile phase was composed of 0.1% trifluoroacetic acid in water and acetonitrile. The flow rate was 1 ml/min and detection wavelength was set at 205 nm and 280 nm. Validation was performed in order to demonstrate selectivity, accuracy and precision of the method. The calibration curves showed good linearity (R (2) > 0.99). The limits of detection and limits of quantification were within the ranges 0.0159-0.6205 μg/ml and 0.3210-1.8802 μg/ml, respectively. Moreover, the relative standard deviations of intra- and inter-day precision were both Dianthus superbus was established by high performance liquid chromatography-diode array detectorDeveloped analysis method is validated with linearity, precious and accuracyThe newly established method was successfully evaluated contents of eight compounds in 12 D. superbus samples (D.1.D.12) from various regions and compared. Abbreviations used: HPLC: High performance liquid chromatography, LOD: Limits of detection, LOQ: Limits of quantification, RSD: Relative standard deviation.

  15. Quantitative analysis of benzodiazepines in vitreous humor by high-performance liquid chromatography

    Science.gov (United States)

    Bazmi, Elham; Behnoush, Behnam; Akhgari, Maryam; Bahmanabadi, Leila

    2016-01-01

    Objective: Benzodiazepines are frequently screened drugs in emergency toxicology, drugs of abuse testing, and in forensic cases. As the variations of benzodiazepines concentrations in biological samples during bleeding, postmortem changes, and redistribution could be biasing forensic medicine examinations, hence selecting a suitable sample and a validated accurate method is essential for the quantitative analysis of these main drug categories. The aim of this study was to develop a valid method for the determination of four benzodiazepines (flurazepam, lorazepam, alprazolam, and diazepam) in vitreous humor using liquid–liquid extraction and high-performance liquid chromatography. Methods: Sample preparation was carried out using liquid–liquid extraction with n-hexane: ethyl acetate and subsequent detection by high-performance liquid chromatography method coupled to diode array detector. This method was applied to quantify benzodiazepines in 21 authentic vitreous humor samples. Linear curve for each drug was obtained within the range of 30–3000 ng/mL with coefficient of correlation higher than 0.99. Results: The limit of detection and quantitation were 30 and 100 ng/mL respectively for four drugs. The method showed an appropriate intra- and inter-day precision (coefficient of variation forensic toxicology laboratory. PMID:27635251

  16. Application of dispersive liquid-liquid microextraction and dispersive micro-solid-phase extraction for the determination of quinolones in swine muscle by high-performance liquid chromatography with diode-array detection

    International Nuclear Information System (INIS)

    Tsai, Wen-Hsien; Chuang, Hung-Yi; Chen, Ho-Hsien; Huang, Joh-Jong; Chen, Hwi-Chang; Cheng, Shou-Hsun; Huang, Tzou-Chi

    2009-01-01

    Dispersive liquid-liquid microextraction (DLLME) and dispersive micro-solid-phase extraction (DMSPE) are two simple and low-cost sample preparation methods for liquid samples. In this work, these two methods were applied to solid tissue sample for the determination of seven quinolones by high-performance liquid chromatography with diode-array detection (HPLC-DAD). After the homogenization of the swine muscle with acetonitrile and salt-promoted partitioning, small amounts of the extract were used for the DLLME and DMSPE methods. In the DLLME approach, the target analytes in the extraction solvent were rapidly extracted into a small volume of dichloromethane for drying and the residue was reconstituted for HPLC-DAD analysis. In the DMSPE approach, the target analytes in the extraction solvent were trapped by dispersive silica-based PSA (primary and secondary amine) sorbents and desorbed into a small amount of desorption solution for HPLC-DAD analysis. Under the optimal conditions, relative recoveries were determined for swine muscle spiked 50-200 μg kg -1 and quantification was achieved by matrix-matched calibration. The calibration curves of seven quinolones showed linearity with a correlation coefficient value above 0.998 for both approaches. Relative recoveries ranged from 93.0 to 104.7% and from 95.5 to 111.0% for DLLME and DMSPE, respectively. Limits of detection (LODs) ranged from 5.6 to 23.8 μg kg -1 and from 7.5 to 26.3 μg kg -1 for DLLME and DMSPE, respectively.

  17. Simultaneous determination of flavonoids, isochlorogenic acids and triterpenoids in Ilex hainanensis Using high performance liquid chromatography coupled with diode array and evaporative light scattering detection.

    Science.gov (United States)

    Peng, Bo; Qiao, Chun-Feng; Zhao, Jing; Huang, Wei-Hua; Hu, De-Jun; Liu, Hua-Gang; Li, Shao-Ping

    2013-03-04

    A high performance liquid chromatography coupled with diode array and evaporative light scattering detection (HPLC-DAD-ELSD) method for simultaneous determination of eight major bioactive compounds including two flavonoids (rutin and eriodictyol-7-O-β-D-glucopyranoside), two isochlorogenic acids (isochlorogenic acid A and isochlorogenic acid C) and four triterpenoids (ilexhainanoside D, ilexsaponin A1, ilexgenin A and ursolic acid) in Ilex hainanensis has been developed for the first time. The 283 nm wavelength was chosen for determination of two flavonoids and two isochlorogenic acids. ELSD was applied to determine four triterpenoids. The analysis was performed on an Agilent Zorbax SB-C18 column (250 × 4.6 mm i.d., 5 µm) with gradient elution of 0.2% formic acid in water and acetonitrile. The method was validated for linearity, limit of detection, limit of quantification, precision, repeatability and accuracy. The proposed method has been successfully applied for simultaneous quantification of the analytes in four samples of Ilex hainanensis, which is helpful for quality control of this plant.

  18. High performance liquid chromatography in pharmaceutical analyses

    Directory of Open Access Journals (Sweden)

    Branko Nikolin

    2004-05-01

    serum contains numerous endogenous compounds often present in concentrations much greater than those of analyte. Analiyte concentrations are often low, and in the case of drugs, the endogenous compounds are sometimes structurally very similar to the drug to be measured. The binding of drugs to the plasma protein also may occur which decreases the amount of free compound that is measured. To undertake the analyses of drugs and metabolites in body fluids the analyst is facet with several problems. The first problem is due to the complex nature of the body fluid, the drugs must be isolated by an extraction technique, which ideally should provide a relatively clean extract, and the separation system must be capable of resolving the drugs of interest from co extractives. All mentioned when we are using high performance liquid chromatography require good selections of detectors, good stationary phase, eluents and adequate program during separation. UV/VIS detector is the most versatile detector used in high performance liquid chromatography it is not always ideal since it is lack of specificity means high resolution of the analyte that may be required. UV detection is preferred since it offers excellent linearity and rapid quantitative analyses can be performed against a single standard of the drug being determined. Diode array and rapid scanning detector are useful for peak identification and monitoring peak purity but they are somewhat less sensitive then single wavelength detectors. In liquid chromatography some components may have a poor UV chromophores if UV detection is being used or be completely retained on the liquid chromatography column. Fluorescence and electrochemical detector are not only considerably more sensitive towed appropriate analytes but also more selective than UV detectors for many compounds. If at all possible fluorescence detectors are sensitive, stable, selective and easy to operate. It is selectivity shows itself in the lack of frontal

  19. Simultaneous determination of eight flavonoids in propolis using chemometrics-assisted high performance liquid chromatography-diode array detection.

    Science.gov (United States)

    Sun, Yan-Mei; Wu, Hai-Long; Wang, Jian-Yao; Liu, Zhi; Zhai, Min; Yu, Ru-Qin

    2014-07-01

    A fast analytical strategy of second-order calibration method based on the alternating trilinear decomposition algorithm (ATLD)-assisted high performance liquid chromatography coupled with a diode array detector (HPLC-DAD) was established for the simultaneous determination of eight flavonoids (rutin, quercetin, luteolin, kaempferol, isorhamnetin, apigenin, galangin and chrysin) in propolis capsules samples. The chromatographic separation was implemented on a Wondasil™ C18 column (250mm×4.6mm, 5μm) within 13min with a binary mobile phase composed of water with 1% formic acid and methanol at a flow rate of 1.0mLmin(-1) after flavonoids were only extracted with methanol by ultrasound extraction for 15min. The baseline problem was overcome by considering background drift as additional compositions or factors as well as the target analytes, and ATLD was employed to handle the overlapping peaks from analytes of interest or from analytes and co-eluting matrix compounds. The linearity was good with the correlation coefficients no less than 0.9947; the limit of detections (LODs) within the range of 3.39-33.05ngmL(-1) were low enough; the accuracy was confirmed by the recoveries ranged from 91.9% to 110.2% and the root-mean-square-error of predictions (RMSEPs) less than 1.1μg/mL. The results indicated that the chromatographic method with the aid of ATLD is efficient, sensitive and cost-effective and can realize the resolution and accurate quantification of flavonoids even in the presence of interferences, thus providing an alternative method for accurate quantification of analytes especially when the complete separation is not easily accomplished. The method was successfully applied to propolis capsules samples and the satisfactory results were obtained. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Solid-Phase Extraction Combined with High Performance Liquid ...

    African Journals Online (AJOL)

    Methods: Solid-phase extraction method was employed for the extraction of the estrogen from milk and high performance liquid chromatography-diode array detector (HPLC-DAD) was used for the determination of estrogen. Results: Optimal chromatographic conditions were achieved on an Eclipse XDB-C18 column at a ...

  1. Analysis of the influence of processing of stir-baking with glycyrrhizae on the main components of Euodiae Fructus by high-performance liquid chromatography with diode array detector.

    Science.gov (United States)

    Hu, Jue; Wu, Xin; Cao, Gang; Chen, Xiaocheng

    2014-01-01

    Euodiae Fructus is one of the most commonly used Chinese herbs in China. Specifically, the crude Euodiae Fructus and its processed products of Gancao Zhi Pin are used clinically for the treatment of different diseases. In order to improve the quality control standard and evaluate the crude and processed Euodiae Fructus, in this study, a simple and sensitive high-performance liquid chromatography-diode array detector method was developed for the simultaneous determination of five major compounds in Euodiae Fructus. The results indicated that the five components had significant linear relation (r(2) ≥ 0.9997) between the peak area and the injected concentration. The average recoveries of the five components were in the range from 97.38% to 102.56%. Overall intra- and inter-day variations were less than 1.36%. The developed method can be applied to the intrinsic quality control of crude and processed Euodiae Fructus.

  2. High-Performance Liquid Chromatography with Diode Array Detector and Electrospray Ionization Ion Trap Time-of-Flight Tandem Mass Spectrometry to Evaluate Ginseng Roots and Rhizomes from Different Regions.

    Science.gov (United States)

    Wang, Hong-Ping; Zhang, You-Bo; Yang, Xiu-Wei; Yang, Xin-Bao; Xu, Wei; Xu, Feng; Cai, Shao-Qing; Wang, Ying-Ping; Xu, Yong-Hua; Zhang, Lian-Xue

    2016-05-09

    Ginseng, Panax ginseng C. A. Meyer, is an industrial crop in China and Korea. The functional components in ginseng roots and rhizomes are characteristic ginsenosides. This work developed a new high-performance liquid chromatography coupled with electrospray ionization ion trap time-of-flight multistage mass spectrometry (LC-ESI-IT-TOF-MS(n)) method to identify the triterpenoids. Sixty compounds (1-60) including 58 triterpenoids were identified from the ginseng cultivated in China. Substances 1, 2, 7, 15-20, 35, 39, 45-47, 49, 55-57, 59, and 60 were identified for the first time. To evaluate the quality of ginseng cultivated in Northeast China, this paper developed a practical liquid chromatography-diode array detection (LC-DAD) method to simultaneously quantify 14 interesting ginsenosides in ginseng collected from 66 different producing areas for the first time. The results showed the quality of ginseng roots and rhizomes from different sources was different due to growing environment, cultivation technology, and so on. The developed LC-ESI-IT-TOF-MS(n) method can be used to identify many more ginsenosides and the LC-DAD method can be used not only to assess the quality of ginseng, but also to optimize the cultivation conditions for the production of ginsenosides.

  3. Determination of Four Major Saponins in Skin and Endosperm of Seeds of Horse Chestnut (Aesculus Hippocastanum L.) Using High Performance Liquid Chromatography with Positive Confirmation by Thin Layer Chromatography

    OpenAIRE

    Abudayeh, Zead Helmi Mahmoud; Al Azzam, Khaldun Mohammad; Naddaf, Ahmad; Karpiuk, Uliana Vladimirovna; Kislichenko, Viktoria Sergeevna

    2015-01-01

    urpose: To separate and quantify four major saponins in the extracts of the skin and the endosperm of seeds of horse chestnut (Aesculus hippocastanum L.) using ultrasonic solvent extraction followed by a high performance liquid chromatography-diode array detector (HPLC-DAD) with positive confirmation by thin layer chromatography (TLC). Methods: The saponins: escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted using ultrasonic extraction method. The optimized ex...

  4. Simultaneous quantification of eight bioactive components of Houttuynia cordata and related Saururaceae medicinal plants by on-line high performance liquid chromatography-diode array detector-electrospray mass spectrometry.

    Science.gov (United States)

    Meng, Jiang; Leung, Kelvin Sze-Yin; Dong, Xiao-Ping; Zhou, Yi-Sheng; Jiang, Zhi-Hong; Zhao, Zhong-Zhen

    2009-12-01

    An on-line high performance liquid chromatography (HPLC)-diode array detector (DAD)-electrospray ionization mass spectrometry (ESI-MS) method has been developed to quantify simultaneously eight bioactive chemical components in Houttuynia cordata Thunb and related Saururaceae medicinal plants. Simultaneous separation of these eight compounds was achieved on a C(18) analytical column with gradient elution of acetonitrile and 0.2% acetic acid (v/v) at a flow rate of 0.6 mL/min and being detected at 280 nm. These eight compounds were completely separated within 90 min. Good linear regression relationship (r(2)>0.9978) within test ranges was shown in all calibration curves. Good repeatabilty for the quantification of these eight compounds in H.cordata was also demonstrated in this method, with intra- and inter-day variations less than 3.0%. The method established was successfully applied to quantify eight bioactive compounds in closely related species of H.cordata, which provides a new basis for quality assessment of H.cordata.

  5. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods.

    Science.gov (United States)

    Shehata, A B; Rizk, M S; Rend, E A

    2016-10-01

    Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis. Copyright © 2016. Published by Elsevier B.V.

  6. Certification of caffeine reference material purity by ultraviolet/visible spectrophotometry and high-performance liquid chromatography with diode-array detection as two independent analytical methods

    Directory of Open Access Journals (Sweden)

    A.B. Shehata

    2016-10-01

    Full Text Available Caffeine reference material certified for purity is produced worldwide, but no research work on the details of the certification process has been published in the literature. In this paper, we report the scientific details of the preparation and certification of pure caffeine reference materials. Caffeine was prepared by extraction from roasted and ground coffee by dichloromethane after heating in deionized water mixed with magnesium oxide. The extract was purified, dried, and bottled in dark glass vials. Stratified random selection was applied to select a number of vials for homogeneity and stability studies, which revealed that the prepared reference material is homogeneous and sufficiently stable. Quantification of caffeine purity % was carried out using a calibrated UV/visible spectrophotometer and a calibrated high-performance liquid chromatography with diode-array detection method. The results obtained from both methods were combined to drive the certified value and its associated uncertainty. The certified value of the reference material purity was found to be 99.86% and its associated uncertainty was ±0.65%, which makes the candidate reference material a very useful calibrant in food and drug chemical analysis.

  7. Identification of Three Kinds of Citri Reticulatae Pericarpium Based on Deoxyribonucleic Acid Barcoding and High-performance Liquid Chromatography-diode Array Detection-electrospray Ionization/Mass Spectrometry/Mass Spectrometry Combined with Chemometric Analysis

    Science.gov (United States)

    Yu, Xiaoxue; Zhang, Yafeng; Wang, Dongmei; Jiang, Lin; Xu, Xinjun

    2018-01-01

    Background: Citri Reticulatae Pericarpium is the dried mature pericarp of Citrus reticulata Blanco which can be divided into “Chenpi” and “Guangchenpi.” “Guangchenpi” is the genuine Chinese medicinal material in Xinhui, Guangdong province; based on the greatest quality and least amount, it is most expensive among others. Hesperidin is used as the marker to identify Citri Reticulatae Pericarpium described in the Chinese Pharmacopoeia 2010. However, both “Chenpi” and “Guangchenpi” contain hesperidin so that it is impossible to differentiate them by measuring hesperidin. Objective: Our study aims to develop an efficient and accurate method to separate and identify “Guangchenpi” from other Citri Reticulatae Pericarpium. Materials and Methods: The genomic deoxyribonucleic acid (DNA) of all the materials was extracted and then the internal transcribed spacer 2 was amplified, sequenced, aligned, and analyzed. The secondary structures were created in terms of the database and website established by Jörg Schultz et al. High-performance liquid chromatography-diode array detection-electrospray Ionization/mass spectrometry (HPLC-DAD-ESI-MS)/MS coupled with chemometric analysis was applied to compare the differences in chemical profiles of the three kinds of Citri Reticulatae Pericarpium. Results: A total of 22 samples were classified into three groups. The results of DNA barcoding were in accordance with principal component analysis and hierarchical cluster analysis. Eight compounds were deduced from HPLC-DAD-ESI-MS/MS. Conclusions: This method is a reliable and effective tool to differentiate the three Citri Reticulatae Pericarpium. SUMMARY The internal transcribed spacer 2 regions and the secondary structure among three kinds of Citri Reticulatae Pericarpium varied considerablyAll the 22 samples were analyzed by high-performance liquid chromatography (HPLC) to obtain the chemical profilesPrincipal component analysis and hierarchical cluster analysis

  8. Application of a diode-array detector in capillary electrophoresis

    NARCIS (Netherlands)

    Beck, W.; Hoek, van R.; Engelhardt, H.

    1993-01-01

    In the last decade diode-array detection has proved to be extremely useful in high performance liquid chromatography in recording UV-visible spectra directly and on-line in the column effluent. In capillary electrophoresis (CE) only fast-scanning detectors with long scan times (up to 2 s) are

  9. Quantitative analysis of flavonols, flavones, and flavanones in fruits, vegetables and beverages by high-performance liquid chromatography with photo-diode array and mass spectrometric detection

    DEFF Research Database (Denmark)

    Justesen, U.; Knuthsen, Pia; Leth, Torben

    1998-01-01

    after acid hydrolysis of freeze-dried food material. Identification was based on retention time, UV and mass spectra by comparison with commercial standards, and the UV peak areas were used for quantitation of the flavonoid contents. Examples of HPLC-MS analyses of orange pulp, tomato, and apple......A high-performance liquid chromatographic (HPLC) separation method viith photo-diode array (PDA) and mass spectrometric (MS) detection was developed to determine and quantify flavonols, flavones, and flavanones in fruits, vegetables and beverages. The compounds were analysed as aglycones, obtained...

  10. Online extraction-high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry for rapid flavonoid profiling of Fructus aurantii immaturus.

    Science.gov (United States)

    Tong, Runna; Peng, Mijun; Tong, Chaoying; Guo, Keke; Shi, Shuyun

    2018-03-01

    Chemical profiling of natural products by high performance liquid chromatography (HPLC) was critical for understanding of their clinical bioactivities, and sample pretreatment steps have been considered as a bottleneck for analysis. Currently, concerted efforts have been made to develop sample pretreatment methods with high efficiency, low solvent and time consumptions. Here, a simple and efficient online extraction (OLE) strategy coupled with HPLC-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS) was developed for rapid chemical profiling. For OLE strategy, guard column inserted with ground sample (2 mg) instead of sample loop was connected with manual injection valve, in which components were directly extracted and transferred to HPLC-DAD-QTOF-MS/MS system only by mobile phase without any extra time, solvent, instrument and operation. By comparison with offline heat-reflux extraction for Fructus aurantii immaturus (Zhishi), OLE strategy presented higher extraction efficiency perhaps because of the high pressure and gradient elution mode. A total of eighteen flavonoids were detected according to their retention times, UV spectra, exact mass, and fragmentation ions in MS/MS spectra, and compound 9, natsudaidain-3-O-glucoside, was discovered in Zhishi for the first time. It is concluded that the developed OLE-HPLC-DAD-QTOF-MS/MS system offers new perspectives for rapid chemical profiling of natural products. Copyright © 2018. Published by Elsevier B.V.

  11. Analysis of chlorpheniramine in human urine samples using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Mehdi Maham

    2014-09-01

    Full Text Available A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM, an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME followed by high performance liquid chromatography with diode array detection (HPLC-DAD. In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent and carbon tetrachloride (extraction solvent was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.

  12. Metabolic profiling of nuciferine in rat urine, plasma, bile and feces after oral administration using ultra-high performance liquid chromatography-diode array detection-quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Wu, Xiao-Lei; Wu, Ming-Jiang; Chen, Xin-Ze; Ma, Hao-Ling; Ding, Li-Qin; Qiu, Feng; Pan, Qin; Zhang, De-Qin

    2017-06-05

    Nuciferine, a major alkaloid found in Nelumbinis Folium, exhibits a broad spectrum of bioactivities, such as antiobesity, anti-diabetes and anti-inflammatory. However, many research regarding nuciferine focused on the extraction, isolation and biological activity, the metabolism is not comprehensively explained in vivo. Thence, the present of this paper is to establish a simple method for speculating metabolites of nuciferine. A total of 15 metabolites were detected and tentatively identified through ultra high performance liquid chromatography-diode array detection-quadrupole time-of-flight mass spectrometry (UHPLC-DAD-QTOF-MS), including 7 new metabolites. Among them, we also discovered a previously unmentioned metabolically active site at the C 1 -OCH 3 position. These metabolites suggested that demethylation, oxidation, glucuronidation and sulfation were major metabolic pathways. This study provided significant experiment basis for its safety estimate and valuable information about the metabolism of nuciferine, which will be advantageous for new drug development. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Simultaneous Determination of Six Food Additives in drinks by high performance liquid chromatography coupled to diode array detector detection

    International Nuclear Information System (INIS)

    Yan, Q.

    2013-01-01

    A reversed-phase high performance liquid chromatographic method for the successful separation and determination of 6 synthetic food additives (aspartame, acesulfame potassium, benzoic acid, sodium saccharin, tartrazine and sunset yellow) was developed. A EclipseXDB-C18 column (250x4.6 mm I.D.; 5 micro m) was used and the mobile phase contained methanol and 0.02 mol/L ammonium acetate (pH 6.0) (30:70, v/v) was pumped at a flow rate of 0.7 mL/min at room temperature. Successful separation conditions were obtained for all the compounds using an optimized gradient elution within 10 min. The diode array detector was used to monitor the food additives at 230 nm. The method was thoroughly validated, detection limits for all substances varied between 0.03 and 1.35 micro g/mg, the intra-day precision (as RSD) ranged from 1.57% to 4.72 %, the inter-day precision (as RSD) was between 2.05 % and 4.18 %. Satisfactory recoveries, ranging from 90.00 % to 109.87 %, were obtained. The proposed system was applied to drink samples. (author)

  14. Characterization of phenolic and other polar compounds in peel and flesh of pink guava (Psidium guajava L. cv. 'Criolla') by ultra-high performance liquid chromatography with diode array and mass spectrometric detection.

    Science.gov (United States)

    Rojas-Garbanzo, Carolina; Zimmermann, Benno F; Schulze-Kaysers, Nadine; Schieber, Andreas

    2017-10-01

    Pink guava (Psidium guajava L.) is a highly consumed fruit in tropical countries. Despite of interesting research on health effects of this fruit, investigations into the profile of secondary plant metabolites are scarce. In this study, the phenolic compounds in the peel and flesh of pink guava were characterized by ultra-high performance liquid chromatography with diode array and mass spectrometric detection. Sixty phenolic compounds were characterized by MS 2 and classified as ellagitannins, flavones, flavonols, flavanols, proanthocyanidins, dihydrochalcones, and anthocyanidins, and non-flavonoids such as phenolic acid derivatives, stilbenes, acetophenones, and benzophenones. Forty-two polyphenols are reported for the first time in both peel and flesh, and twenty-four compounds were detected for the first time in P. guajava, e.g., phlorizin, nothofagin, astringin, chrysin-C-glucoside, valoneic acid bilactone, cinnamoyl-glucoside, and two dimethoxycinnamoyl-hexosides. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Simultaneous determination of caffeine, paracetamol, and ibuprofen in pharmaceutical formulations by high-performance liquid chromatography with UV detection and by capillary electrophoresis with conductivity detection.

    Science.gov (United States)

    Cunha, Rafael R; Chaves, Sandro C; Ribeiro, Michelle M A C; Torres, Lívia M F C; Muñoz, Rodrigo A A; Dos Santos, Wallans T P; Richter, Eduardo M

    2015-05-01

    Paracetamol, caffeine and ibuprofen are found in over-the-counter pharmaceutical formulations. In this work, we propose two new methods for simultaneous determination of paracetamol, caffeine and ibuprofen in pharmaceutical formulations. One method is based on high-performance liquid chromatography with diode-array detection and the other on capillary electrophoresis with capacitively coupled contactless conductivity detection. The separation by high-performance liquid chromatography with diode-array detection was achieved on a C18 column (250×4.6 mm(2), 5 μm) with a gradient mobile phase comprising 20-100% acetonitrile in 40 mmol L(-1) phosphate buffer pH 7.0. The separation by capillary electrophoresis with capacitively coupled contactless conductivity detection was achieved on a fused-silica capillary (40 cm length, 50 μm i.d.) using 10 mmol L(-1) 3,4-dimethoxycinnamate and 10 mmol L(-1) β-alanine with pH adjustment to 10.4 with lithium hydroxide as background electrolyte. The determination of all three pharmaceuticals was carried out in 9.6 min by liquid chromatography and in 2.2 min by capillary electrophoresis. Detection limits for caffeine, paracetamol and ibuprofen were 4.4, 0.7, and 3.4 μmol L(-1) by liquid chromatography and 39, 32, and 49 μmol L(-1) by capillary electrophoresis, respectively. Recovery values for spiked samples were between 92-107% for both proposed methods. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Simultaneous separation of antihyperlipidemic drugs by green ultrahigh-performance liquid chromatography-diode array detector method: Improving the health of liquid chromatography.

    Science.gov (United States)

    Alghazi, Mansoor; Alanazi, Fars; Mohsin, Kazi; Siddiqui, Nasir Ali; Shakeel, Faiyaz; Haq, Nazrul

    2017-04-01

    Statins in combination with fibrates show beneficial effects on the lipoprotein profile of patients because they have positive complimentary effects on lipid profile. A new green ultrahigh-performance liquid chromatography-diode array detector method for simultaneous analysis of simvastatin (SMV) and fenofibrate (FNF) in standard form, marketed formulations, and self-emulsifying drug delivery system formulations was developed and validated in the present investigation. The method utilized C 18 as stationary phase and a combination of methanol:water (8:2) as an eluent. It was found that selected eluent provided short run time (2.5 minutes), better peak symmetry and satisfactory values of other chromatographic parameters such as resolution (Rs=2.325), capacity factor (k, 3.0 and 4.2 for SMV and FNF, respectively), selectivity (α =1.4), and number of theoretical plates (N, 4265 and 5285 for SMV and FNF, respectively). An excellent linear relationship (r 2 0.998 and 0.997 for SMV and FNF, respectively) was observed for linear regression data for the calibration plots. The developed system was validated for accuracy, precision, robustness (˃ 2% for both drugs) and recovery (98-102% for both drugs). Results obtained from the statistical treatment of the values obtained for different parameters proved that the method is suitable, reproducible, and selective for the simultaneous analysis of SMV and FNF in bulk, marketed, and self-emulsifying drug delivery system formulations. The replacement of commonly applied toxic solvents with innocuous and environmentally benign solvents provides a better option than the more toxic processes in drug analysis. Copyright © 2016. Published by Elsevier B.V.

  17. A novel liquid chromatography method using diode-array detector for the determination of oleuropein in dietary supplements.

    Science.gov (United States)

    Bertolini, Tiziana; Vicentini, Lorenza; Boschetti, Silvia; Andreatta, Paolo; Gatti, Rita

    2016-09-10

    A simple and fast chromatographic method using ultraviolet diode-array detector (UV-DAD) was developed for the automatic high performance liquid chromatography (HPLC) determination of the title of oleuropein in a new dietary supplements in form of effervescent granules. The chromatographic separations were performed on a C18 core-shell column with detection at λ=232nm. The mobile phase consisted of deionized water with 0.1% TFA and acetonitrile under gradient conditions at a flow-rate of 0.8mL/min. Oleuropein and oleuroside present in the raw material were characterized by high performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). The validation of the analytical procedure has been performed determining the following parameters: specificity, linearity, repeatability, reproducibility, accuracy, limit of quantification (LOQ), stability of the standard and sample solutions. Linear response was observed in fortified placebo solutions (determination coefficient: 0.9998). Intra-day precision (relative standard deviation, RSD) was ≤5.0% for peak area and for retention times (tR) without significant differences between intra- and inter-day data. The limits of quantitation (LOQ) was about 5μg/mL and 9pmol/inject. Oleuropein recovery studies gave good results (99.9%) with a R.S.D. of 0.5%. The speed of analysis and the stability of the solutions with a fluctuation Δ (%) ≤2.0 at room temperature means an undoubted advantage of the method allowing the simultaneous preparation of many samples and consecutive chromatographic analyses by using an autosampler. The developed method is suitable for the quality control of oleuropein in raw material and industrial products. The method can be applied in any analytical laboratory not requiring a sophisticated instrumentation. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Determination of phenmedipham and desmedipham in a commercial herbicide by high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Lončar Eva S.

    2004-01-01

    Full Text Available Betanal AM-11 is the herbicide that is using to control one-year old weeds with wide leafs in sugar beet fields. Active ingredients of the herbicide are phenmedipham and desmedipham. Commercial emulsifiable concentrate (EC contains 80 g/L ( 10% of each active compound. We applied high performance liquid chromatography (HPLC with diode array detector (DAD at 254 nm for the determination of phenmedipham and desmedipham in commercial samples of Betanal AM-11. This method involves reversed-phase separation of the components on C-18 bonded silica with methanol-water (51+49, v/v as the eluent. The procedure was highly selective and reproducible and can be successfully used in determining contents of phenmedipham and desmedipham on micro and macro levels.

  19. Rapid Identification of unstable acyl glucoside flavonoids of Oxytropis racemosa Turcz by high-performance liquid chromatography-diode array detection-electrospray ionisation/multi-stage mass spectrometry.

    Science.gov (United States)

    Song, Shuang; Zheng, Xiu-Ping; Liu, Wei-Dong; Du, Rui-Fang; Feng, Zi-Ming; Zhang, Pei-Cheng; Bi, Li-Fu

    2013-02-01

    Oxytropis racemosa Turcz is an important minority medicine that is used mainly to improve children's indigestion, especially in inner Mongolia and Tibet. Previous studies indicated that the characteristic constituents of this plant are acylated flavonoids. Rapidly identify the characteristic chemical constituents of O. racemosa by high-performance liquid chromatography-diode array detection-electrospray ionisation/multi-stage mass spectrometry (HPLC-DAD-ESI/MS(n) ) and suggest a useful method to control the quality of this medicinal plant. In the HPLC fingerprint, 32 flavonoids were tentatively identified by a detailed analysis of their mass spectra, UV spectra and retention times. Furthermore, 13 flavonoids were confirmed by comparison with previously isolated compounds obtained from O. racemosa. In total, 32 flavonoids, including 13 flavonoids with 3-hydroxy-3-methylglutaric acid (HMG) moieties and four flavonoids with 3-malonyl moieties, were identified in the extract of O. racemosa. Among the compounds identified, 10 were characterised as new compounds for their particular acylated sugar moieties. The method described is effective for obtaining a comprehensive phytochemical profile of plants containing unstable acylated flavonoids. The method is also useful for constructing the chromatographic fingerprint of the minority medicine -O. racemosa Turcz for quality control. Copyright © 2012 John Wiley & Sons, Ltd.

  20. High performance liquid chromatography (HPLC fingerprints and primary structure identification of corn peptides by HPLC-diode array detection and HPLC-electrospray ionization tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Chi Wang

    2016-01-01

    Full Text Available Corn peptides (CPs are reported to have many biological functions, such as facilitating alcohol metabolism, antioxidation, antitumor, antihypertension, and hepatoprotection. To develop a method for quality control, the high-performance liquid chromatography (HPLC system was applied. Twenty-eight common peaks were found in all the CPs of corn samples from Enshi, China, based on which, a fingerprinting chromatogram was established for use in quality control in future research. Subsequently, the major chemical constituents of these common peaks were identified respectively using the HPLC-diode-array detection electrospray ionization tandem mass spectrometry (DAD-ESI-MS/MS system, and 48 peptide fractions were determined ultimately. This was the first time for the majority of these peptides to be reported, and many of them contained amino acids of glutamine (Q, L and A, which might play an important role in the exhibition of the bioactivities of CPs. Many peptides had a similar primary structure to the peptides which had been proven to be bioactive such as facilitating alcohol metabolism, scavenging free radicals, and inhibiting lipid peroxidation. This systematical analysis of the primary structure of CPs facilitated subsequent studies on the relationship between the structures and functions, and could accelerate holistic research on CPs.

  1. Determination of patulin in apple juice by high-performance liquid chromatography with diode-array detection.

    Science.gov (United States)

    Bartolomé, B; Bengoechea, M L; Pérez-Ilzarbe, F J; Hernández, T; Estrella, I; Gómez-Cordovés, C

    1994-03-25

    A method is described for the detection of patulin in apple juice and the simultaneous determination of the phenolic composition. Spectral data obtained with diode-array detection showed that patulin can be easily distinguished from compounds eluting under the same conditions. The detection limit for patulin was 8.96 micrograms/l.

  2. Trace analysis of tiamulin in honey by liquid chromatography-diode array-electrospray ionization mass spectrometry detection.

    Science.gov (United States)

    Nozal, M J; Bernal, J L; Martín, M T; Jiménez, J J; Bernal, J; Higes, M

    2006-05-26

    A liquid chromatography with diode array or electrospray ionisation mass spectrometry detection (LC-DAD-ESI-MS) method for the determination of tiamulin residues in honey is presented. The procedure employs a solid-phase extraction (SPE) on polymeric cartridges for the isolation of tiamulin from honey samples diluted in aqueous solution of tartaric acid. Chromatographic separation of the tiamulin is performed, in isocratic mode, on a C18 column using methanol and ammonium carbonate 0.1% in water, in proportion (30:70, v/v). Average analyte recoveries were from 88 to 106% in replica sets of fortified honey samples. The LC-ESI-MS method detection limits differ from 0.5 microg kg(-1) for clear honeys to 1.2 microg kg(-1) for dark honeys. The developed method has been applied to the analysis of tiamulin residues in multifloral honey samples collected from veterinary treated beehives.

  3. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma.

    Science.gov (United States)

    Carmo, Ana Paula Barbosa do; Borborema, Manoella; Ribeiro, Stephan; De-Oliveira, Ana Cecilia Xavier; Paumgartten, Francisco Jose Roma; Moreira, Davyson de Lima

    2017-01-01

    Primaquine (PQ) diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV ) analysis of PQ in the blood plasma was developed and validated. After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm) as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80) (45:55) as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD) and quantification (LOQ) limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral) PQ diphosphate. By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  4. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma

    Directory of Open Access Journals (Sweden)

    Ana Paula Barbosa do Carmo

    Full Text Available Abstract INTRODUCTION: Primaquine (PQ diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV analysis of PQ in the blood plasma was developed and validated. METHODS: After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80 (45:55 as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD and quantification (LOQ limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral PQ diphosphate. RESULTS: By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. CONCLUSIONS: The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  5. Development of a high performance liquid chromatography method ...

    African Journals Online (AJOL)

    Development of a high performance liquid chromatography method for simultaneous ... Purpose: To develop and validate a new low-cost high performance liquid chromatography (HPLC) method for ..... Several papers have reported the use of ...

  6. Metabolite fingerprinting of Punica granatum L. (pomegranate) polyphenols by means of high-performance liquid chromatography with diode array and electrospray ionization-mass spectrometry detection.

    Science.gov (United States)

    Brighenti, Virginia; Groothuis, Sebastiaan Frearick; Prencipe, Francesco Pio; Amir, Rachel; Benvenuti, Stefania; Pellati, Federica

    2017-01-13

    The present study was aimed at the development of a new analytical method for the comprehensive multi-component analysis of polyphenols in Punica granatum L. (pomegranate) juice and peel. While pomegranate juice was directly analysed after simple centrifugation, different extraction techniques, including maceration, heat reflux extraction, ultrasound-assisted extraction and microwave-assisted extraction, were compared in order to obtain a high yield of the target analytes from pomegranate peel. Dynamic maceration with a mixture of water and ethanol 80:20 (v/v) with 0.1% of hydrochloric acid as the extraction solvent provided the best result in terms of recovery of pomegranate secondary metabolites. The quali- and quantitative analysis of pomegranate polyphenols was performed by high-performance liquid chromatography with diode array and electrospray ionization-mass spectrometry detection. The application of fused-core column technology allowed us to obtain an improvement of the chromatographic performance in comparison with that of conventional particulate stationary phases, thus enabling a good separation of all constituents in a shorter time and with low solvent usage. The analytical method was completely validated to show compliance with the International Conference on Harmonization of Technical Requirements for the Registration of Pharmaceuticals for Human Use guidelines and successfully applied to the characterisation of commercial and experimental pomegranate samples, thus demonstrating its efficiency as a tool for the fingerprinting of this plant material. The quantitative data collected were submitted to principal component analysis, in order to highlight the possible presence of pomegranate samples with high content of secondary metabolites. From the statistical analysis, four experimental samples showed a notable content of bioactive compounds in the peels, while commercial ones still represent the best source of healthy juice. Copyright © 2016 Elsevier

  7. Quantitative analysis of the eight major compounds in the Samsoeum using a high-performance liquid chromatography coupled with diode array detection and electrospray ionization mass spectrometer

    Science.gov (United States)

    Weon, Jin Bae; Yang, Hye Jin; Lee, Bohyoung; Ma, Jin Yeul; Ma, Choong Je

    2015-01-01

    Background: Samsoeum was traditionally used for treatment of a respiratory disease. Objective: The simultaneous determination of eight major compounds, ginsenoside Rg3, caffeic acid, puerarin, costunolide, hesperidin, naringin, glycyrrhizin, and 6-gingerol in the Samsoeum using a high-performance liquid chromatography (HPLC) coupled with diode array detection (DAD) and an electrospray ionization mass spectrometer was developed for an accurate and reliable quality assessment. Materials and Methods: Eight compounds were qualitative identified based on their mass spectra and by comparing with standard compounds and quantitative analyzed by HPLC-DAD. Separation of eight compounds was carried out on a LUNA C18 column (S-5 μm, 4.6 mm i.d. ×250 mm) with gradient elution composed of acetonitrile and 0.1% trifluoroacetic acid. Results: The data showed good linearity (R2 > 0.9996). The limits of detection and the limits of quantification were <0.53 μg and 1.62 μg, respectively. Inter- and Intra-day precisions (expressed as relative standard deviation values) were within 1.94% and 1.91%, respectively. The recovery of the method was in the range of 94.24–107.90%. Conclusion: The established method is effective and could be applied to quality control of Samsoeum. PMID:25829771

  8. Quantitative Analysis and Comparison of Four Major Flavonol Glycosides in the Leaves of Toona sinensis (A. Juss.) Roemer (Chinese Toon) from Various Origins by High-Performance Liquid Chromatography-Diode Array Detector and Hierarchical Clustering Analysis

    Science.gov (United States)

    Sun, Xiaoxiang; Zhang, Liting; Cao, Yaqi; Gu, Qinying; Yang, Huan; Tam, James P.

    2016-01-01

    Background: Toona sinensis (A. Juss.) Roemer is an endemic species of Toona genus native to Asian area. Its dried leaves are applied in the treatment of many diseases; however, few investigations have been reported for the quantitative analysis and comparison of major bioactive flavonol glycosides in the leaves harvested from various origins. Objective: To quantitatively analyze four major flavonol glycosides including rutinoside, quercetin-3-O-β-D-glucoside, quercetin-3-O-α-L-rhamnoside, and kaempferol-3-O-α-L-rhamnoside in the leaves from different production sites and classify them according to the content of these glycosides. Materials and Methods: A high-performance liquid chromatography-diode array detector (HPLC-DAD) method for their simultaneous determination was developed and validated for linearity, precision, accuracy, stability, and repeatability. Moreover, the method established was then employed to explore the difference in the content of these four glycosides in raw materials. Finally, a hierarchical clustering analysis was performed to classify 11 voucher specimens. Results: The separation was performed on a Waters XBridge Shield RP18 column (150 mm × 4.6 mm, 3.5 μm) kept at 35°C, and acetonitrile and H2O containing 0.30% trifluoroacetic acid as mobile phase was driven at 1.0 mL/min during the analysis. Ten microliters of solution were injected and 254 nm was selected to monitor the separation. A strong linear relationship between the peak area and concentration of four analytes was observed. And, the method was also validated to be repeatable, stable, precise, and accurate. Conclusion: An efficient and reliable HPLC-DAD method was established and applied in the assays for the samples from 11 origins successfully. Moreover, the content of those flavonol glycosides varied much among different batches, and the flavonoids could be considered as biomarkers to control the quality of Chinese Toon. SUMMARY Four major flavonol glycosides in the leaves

  9. Development and validation of a rapid ultra-high performance liquid chromatography diode array detector method for Vitex agnus-castus.

    Science.gov (United States)

    Högner, C; Sturm, S; Seger, C; Stuppner, H

    2013-05-15

    A rapid ultra-high performance liquid chromatography diode array detector (UHPLC-DAD) method was developed and validated for the simultaneous determination of all classes of non-volatile phytochemicals (iridoids, flavonoids and diterpenes) in Vitex agnus-castus (Lamiaceae) fruits, a traditional medicinal plant used against premenstrual symptoms (PMS) and other disorders. Seven marker compounds, 3,4-dihydroxybenzoic acid, p-hydroxybenzoic acid, agnuside, 5-hydroxykaempferol-3,6,7,4'-tetramethylether, 1,2-dibenzoic acid glucose, methoxy-vitexilactone, and vitetrifolin D were isolated from the methanol extract of V. agnus-castus to be used as reference substances. Chromatographic separation was performed on a Zorbax Eclipse XDB-C18 (50mm×2.1mm) UHPLC column with 1.8μm particle size, within 20min. A solvent gradient from 0.5% acetic acid to acetonitrile at a flow rate of 0.6mL/min was used as mobile phase. Analyte detection and quantification was realized at 210nm and 260nm. The UHPLC-DAD assay was validated for the quantitative analysis of agnuside, isovitexin, casticin, 5-hydroxykaempferol-3,6,7,4'-tetramethylether and vitetrifolin D. It was found to be specific, accurate, precise, and reproducible for the quantification of these compound within a concentration range of 0.7-500.0μg/mL for casticin and 5-hydroxykaempferol-3,6,7,4'-tetramethylether, 1.4-1000.0μg/mL for isovitexin and agnuside, and 12.4-1000.0μg/mL for vitetrifolin D. Intra- and inter-day variations showed relative standard deviations (RSD) of less than 3.9% and 6.4%, respectively. Tentatively assignment of 62 chromatographic features found in the UHPLC-DAD assay was carried out by coupling the UHPLC instrument to a quadrupole time-of-flight mass spectrometer via an electrospray ionization interface (ESI-QTOF-MS) operated in positive and negative ion mode. By using the established quantitative UHPLC-DAD assay to asses agnuside, isovitexin, casticin, 5-hydroxykaempferol-3,6,7,4'-tetramethylether and

  10. Determination of diflubenzuron and chlorbenzuron in fruits by combining acetonitrile-based extraction with dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan

    2015-09-01

    In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Qualitative and Quantitative Analysis of Volatile Components of Zhengtian Pills Using Gas Chromatography Mass Spectrometry and Ultra-High Performance Liquid Chromatography.

    Science.gov (United States)

    Liu, Cui-Ting; Zhang, Min; Yan, Ping; Liu, Hai-Chan; Liu, Xing-Yun; Zhan, Ruo-Ting

    2016-01-01

    Zhengtian pills (ZTPs) are traditional Chinese medicine (TCM) which have been commonly used to treat headaches. Volatile components of ZTPs extracted by ethyl acetate with an ultrasonic method were analyzed by gas chromatography mass spectrometry (GC-MS). Twenty-two components were identified, accounting for 78.884% of the total components of volatile oil. The three main volatile components including protocatechuic acid, ferulic acid, and ligustilide were simultaneously determined using ultra-high performance liquid chromatography coupled with diode array detection (UHPLC-DAD). Baseline separation was achieved on an XB-C18 column with linear gradient elution of methanol-0.2% acetic acid aqueous solution. The UHPLC-DAD method provided good linearity (R (2) ≥ 0.9992), precision (RSD components, protocatechuic acid, ferulic acid, and ligustilide, in 13 batches of ZTPs, which is suitable for discrimination and quality assessment of ZTPs.

  12. [High-performance liquid-liquid chromatography in beverage analysis].

    Science.gov (United States)

    Bricout, J; Koziet, Y; de Carpentrie, B

    1978-01-01

    Liquid liquid chromatography was performed with columns packed with stationary phases chemically bonded to silica microparticules. These columns show a high efficiency and are used very easily. Flavouring compounds like aromatic aldehydes which have a low volatility were analyzed in brandy using a polar phase alkylnitrile. Sapid substances like amarogentin in Gentiana lutea or glyryrrhizin in Glycyrrhiza glabra were determined by reversed phase chromatography. Finally ionizable substances like synthetic dyes can be analyzed by paired ion chromatography witha non polar stationary phase.

  13. Two-way and three-way approaches to ultra high performance liquid chromatography-photodiode array dataset for the quantitative resolution of a two-component mixture containing ciprofloxacin and ornidazole.

    Science.gov (United States)

    Dinç, Erdal; Ertekin, Zehra Ceren; Büker, Eda

    2016-09-01

    Two-way and three-way calibration models were applied to ultra high performance liquid chromatography with photodiode array data with coeluted peaks in the same wavelength and time regions for the simultaneous quantitation of ciprofloxacin and ornidazole in tablets. The chromatographic data cube (tensor) was obtained by recording chromatographic spectra of the standard and sample solutions containing ciprofloxacin and ornidazole with sulfadiazine as an internal standard as a function of time and wavelength. Parallel factor analysis and trilinear partial least squares were used as three-way calibrations for the decomposition of the tensor, whereas three-way unfolded partial least squares was applied as a two-way calibration to the unfolded dataset obtained from the data array of ultra high performance liquid chromatography with photodiode array detection. The validity and ability of two-way and three-way analysis methods were tested by analyzing validation samples: synthetic mixture, interday and intraday samples, and standard addition samples. Results obtained from two-way and three-way calibrations were compared to those provided by traditional ultra high performance liquid chromatography. The proposed methods, parallel factor analysis, trilinear partial least squares, unfolded partial least squares, and traditional ultra high performance liquid chromatography were successfully applied to the quantitative estimation of the solid dosage form containing ciprofloxacin and ornidazole. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Sensitive determination of nitrophenol isomers by reverse-phase high-performance liquid chromatography in conjunction with liquid-liquid extraction

    Science.gov (United States)

    A method for the highly sensitive determination of 2-, 3- and 4- nitrophenols was developed using reverse-phase high-performance liquid chromatography (RP-HPLC) with a UV photodiode array detector. Using a reverse-phase column and 40% aqueous acetonitrile as an eluent (i.e. isocratic elution), the i...

  15. Qualitative and quantitative analysis of an alkaloid fraction from Piper longum L. using ultra-high performance liquid chromatography-diode array detector-electrospray ionization mass spectrometry.

    Science.gov (United States)

    Li, Kuiyong; Fan, Yunpeng; Wang, Hui; Fu, Qing; Jin, Yu; Liang, Xinmiao

    2015-05-10

    In a previous research, an alkaloid fraction and 18 alkaloid compounds were prepared from Piper longum L. by series of purification process. In this paper, a qualitative and quantitative analysis method using ultra-high performance liquid chromatography-diode array detector-mass spectrometry (UHPLC-DAD-MS) was developed to evaluate the alkaloid fraction. Qualitative analysis of the alkaloid fraction was firstly completed by UHPLC-DAD method and 18 amide alkaloid compounds were identified. A further qualitative analysis of the alkaloid fraction was accomplished by UHPLC-MS/MS method. Another 25 amide alkaloids were identified according to their characteristic ions and neutral losses. At last, a quantitative method for the alkaloid fraction was established using four marker compounds including piperine, pipernonatine, guineensine and N-isobutyl-2E,4E-octadecadienamide. After the validation of this method, the contents of above four marker compounds in the alkaloid fraction were 57.5mg/g, 65.6mg/g, 17.7mg/g and 23.9mg/g, respectively. Moreover, the relative response factors of other three compounds to piperine were calculated. A comparative study between external standard quantification and relative response factor quantification proved no remarkable difference. UHPLC-DAD-MS method was demonstrated to be a powerful tool for the characterization of the alkaloid fraction from P. longum L. and the result proved that the quality of alkaloid fraction was efficiently improved after appropriate purification. Copyright © 2015. Published by Elsevier B.V.

  16. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    Science.gov (United States)

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Development and validation of an high-performance liquid chromatography-diode array detector method for the simultaneous determination of six phenolic compounds in abnormal savda munziq decoction

    Science.gov (United States)

    Tian, Shuge; Liu, Wenxian; Liu, Feng; Zhang, Xuejia; Upur, Halmuart

    2015-01-01

    Aims: Given the high-effectiveness and low-toxicity of abnormal savda munziq (ASMQ), its herbal formulation has long been used in traditional Uyghur medicine to treat complex diseases, such as cancer, diabetes, and cardiovascular diseases. Settings and Design: ASMQ decoction by reversed-phase high-performance liquid chromatography coupled with a diode array detector was successfully developed for the simultaneous quality assessment of gallic acid, protocatechuic acid, caffeic acid, rutin, rosmarinic acid, and luteolin. The six phenolic compounds were separated on an Agilent TC-C18 reversed-phase analytical column (4.6 × 250 mm, 5 μm) by gradient elution using 0.3% aqueous formic acid (v/v) and 0.3% methanol formic acid (v/v) at 1.0 mL/min. Materials and Methods: The plant material was separately ground and mixed at the following ratios (10): Cordia dichotoma (10.6), Anchusa italic (10.6), Euphorbia humifusa (4.9), Adiantum capillus-veneris (4.9), Ziziphus jujube (4.9), Glycyrrhiza uralensis (7.1), Foeniculum vulgare (4.9), Lavandula angustifolia (4.9), Dracocephalum moldavica L. (4.9), and Alhagi pseudoalhagi (42.3). Statistical Analysis Used: The precisions of all six compounds were Highly significant linear correlations were found between component concentrations and specific chromatographic peak areas (R2 > 0.999). Results: The proposed method was successfully applied to determine the levels of six active components in ASMQ. Conclusions: Given the simplicity, precision, specificity, and sensitivity of the method, it can be utilized as a quality control approach to simultaneously determining the six phenolic compounds in AMSQ. PMID:25709227

  18. Characterisation of chemical components for identifying historical Chinese textile dyes by ultra high performance liquid chromatography – photodiode array – electrospray ionisation mass spectrometer

    NARCIS (Netherlands)

    Han, J.; Wanrooij, J.; van Bommel, M.; Quye, A.

    2017-01-01

    This research makes the first attempt to apply Ultra High Performance Liquid Chromatography (UHPLC) coupled to both Photodiode Array detection (PDA) and Electrospray Ionisation Mass Spectrometer (ESI–MS) to the chemical characterisation of common textile dyes in ancient China. Three different

  19. Simultaneous determination of the content of isoquinoline alkaloids in Dicranostigma leptopodum (Maxim) Fedde and the effective fractionation of the alkaloids by high-performance liquid chromatography with diode array detection.

    Science.gov (United States)

    Chen, Yali; Li, Min; Liu, Jianjun; Yan, Qian; Zhong, Mei; Liu, Junxi; Di, Duolong; Liu, Jinxia

    2015-01-01

    A simple and efficient method was developed for the simultaneous determination of eight isoquinoline alkaloids in methanol extracts of Dicranostigma leptopodum (Maxim) Fedde and the effective fractionation of the alkaloids of D. leptopodum by high-performance liquid chromatography with diode array detection. The chromatographic conditions were optimized on a SinoChrom ODS-BP column to obtain a good separation of the four types of alkaloid analytes, including two aporphines (isocorydine, corydine), two protopines (protopine and allocryptopine), a morphine (sinoacutine), and three quaternary protoberberine alkaloids (berberrubine, 5-hydroxycoptisine, and berberine). The separation of these alkaloids was significantly affected by the composition of the mobile phase, and particularly by its pH value. Acetonitrile (A) and 0.2% phosphoric acid solution adjusted to pH 6.32 with triethylamine (B) were selected as the mobile phase with a gradient elution. With this method, a new quaternary protoberberine alkaloid was isolated and the two structural isomers (isocorydine and corydine) were baseline separated. The appropriate harvest period for D. leptopodum was also recommended based on our analysis. The method for the effective fraction of the alkaloids of D. leptopodum was optimized under this method with regard to the varying significant pharmacological activities of the alkaloids. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Identification and Quantification of Flavonoids and Phenolic Acids in Burr Parsley (Caucalis platycarpos L., Using High-Performance Liquid Chromatography with Diode Array Detection and Electrospray Ionization Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Ana Mornar

    2009-07-01

    Full Text Available A sensitive method coupling high-performance liquid chromatography (HPLC with diode-array detector (DAD and electrospray ionization mass spectrometry (MS was optimized for the separation and identification of phenolic acids, flavonoid glycosides and flavonoid aglycones in the extract of burr parsley (Caucalis platycarpos L.. Fragmentation behavior of flavonoid glycosides and phenolic acids were investigated using ion trap mass spectrometry in negative electrospray ionization. The MS, MSn and UV data together with HPLC retention time (TR of phenolic acids and flavonoids allowed structural characterization of these compounds. Caffeoylquinic acid (CQA isomers, p-coumaroyl-quinic acids (p-CoQA, feruloylquinic acids (FQA, dicaffeoylquinic acids (diCQA, luteolin-7-O-rutinoside, apigenin-7-O-rutinoside as well as isolated chrysoeriol-7-O-rutinoside have been identified as constituents of C. platycarpos for the first time. An accurate, precise and sensitive LC-DAD method for quantification of four phenolic acids (3-O-caffeoylquinic, caffeic, p-coumaric, o-coumaric acid, four flavonoid glycosides (luteolin-7-O-glucoside, apigenin-7-O-glucoside, quercetin-3-O-galactoside, quercetin-3-O-rhamnoside, and three flavonoid aglycones (luteolin, apigenin, chrysoeriol in C. platycarpos extract was validated in terms of linearity, limit of detection, limit of quantification, precision and accuracy. 3-O-caffeoylquinic acid was the predominant phenolic acid and luteolin-7-O-glucoside was the predominant flavonoid glycoside.

  1. Gradient High Performance Liquid Chromatography Method ...

    African Journals Online (AJOL)

    Purpose: To develop a gradient high performance liquid chromatography (HPLC) method for the simultaneous determination of phenylephrine (PHE) and ibuprofen (IBU) in solid ..... nimesulide, phenylephrine. Hydrochloride, chlorpheniramine maleate and caffeine anhydrous in pharmaceutical dosage form. Acta Pol.

  2. Identification of tyrosinase specific inhibitors from Xanthium strumarium fruit extract using ultrafiltration-high performance liquid chromatography.

    Science.gov (United States)

    Wang, Zhiqiang; Hwang, Seung Hwan; Huang, Bo; Lim, Soon Sung

    2015-10-01

    In this study, a strategy based on ultrafiltration-high performance liquid chromatography coupled with diode array detection (UF-HPLC-DAD) was proposed for screening tyrosinase specific inhibitors in Xanthii fructus. The false negatives were distinguished by optimizing the UF-HPLC-DAD parameters to reduce the background noise; the false positives were distinguished by introducing a blocked tyrosinase in the control group for comparison. To obtain the best blocker, the competitive experiments were performed using various known ligands. Using this strategy, three competitive inhibitors (protocatechuic acid; 3,5-di-O-caffeoylquinic acid; and 1,5-di-O-caffeoylquinic acid) and one mixed-type inhibitor (chlorogenic acid) were identified. These results were verified using tyrosinase inhibition assay, kinetic analysis, and structural simulation of the complex. Our experimental results suggest that the proposed strategy could be useful for high-throughput identification of tyrosinase specific inhibitors in natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Characterization of High-power Quasi-cw Laser Diode Arrays

    Science.gov (United States)

    Stephen, Mark A.; Vasilyev, Aleksey; Troupaki, Elisavet; Allan, Graham R.; Kashem, Nasir B.

    2005-01-01

    NASA s requirements for high reliability, high performance satellite laser instruments have driven the investigation of many critical components; specifically, 808 nm laser diode array (LDA) pump devices. Performance and comprehensive characterization data of Quasi-CW, High-power, laser diode arrays is presented.

  4. Identification of complex, naturally occurring flavonoid glycosides in kale (Brassica oleracea var. sabellica) by high-performance liquid chromatography diode-array detection/electrospray ionization multi-stage mass spectrometry.

    Science.gov (United States)

    Schmidt, Susanne; Zietz, Michaela; Schreiner, Monika; Rohn, Sascha; Kroh, Lothar W; Krumbein, Angelika

    2010-07-30

    Kale is a member of the Brassicaceae family and has a complex profile of flavonoid glycosides. Therefore, kale is a suitable matrix to discuss in a comprehensive study the different fragmentation patterns of flavonoid glycosides. The wide variety of glycosylation and acylation patterns determines the health-promoting effects of these glycosides. The aim of this study is to investigate the naturally occurring flavonoids in kale. A total of 71 flavonoid glycosides of quercetin, kaempferol and isorhamnetin were identified using a high-performance liquid chromatography diode-array detection/electrospray ionization multi-stage mass spectrometry (HPLC-DAD/ESI-MS(n)) method. Of these 71 flavonol glycosides, 27 were non-acylated, 30 were monoacylated and 14 were diacylated. Non-acylated flavonol glycosides were present as mono-, di-, tri- and tetraglycosides. This is the first time that the occurrence of four different fragmentation patterns of non-acylated flavonol triglycosides has been reported in one matrix simultaneously. In addition, 44 flavonol glycosides were acylated with p-coumaric, caffeic, ferulic, hydroxyferulic or sinapic acid. While monoacylated glycosides existed as di-, tri- and tetraglycosides, diacylated glycosides occurred as tetra- and pentaglycosides. To the best of our knowledge, 28 compounds in kale are reported here for the first time. These include three acylated isorhamnetin glycosides (isorhamnetin-3-O-sinapoyl-sophoroside-7-O-D-glucoside, isorhamnetin-3-O-feruloyl-sophoroside-7-O-diglucoside and isorhamnetin-3-O-disinapoyl-triglucoside-7-O-diglucoside) and seven non-acylated isorhamnetin glycosides. Copyright 2010 John Wiley & Sons, Ltd.

  5. Determination of ascorbic acid by high performance liquid chromatography (H. P. L. C.) using photodiode array detector

    International Nuclear Information System (INIS)

    Elbashier, E. E.; Greenway, G. M; Townshend, A.

    2005-01-01

    This paper describes a simple and rapid method for the determination of vitamin C using H. P. L. C. A reversed phase C 1 8 column was used to perform ion pairing chromatography, the ion pairing agent tri-n-butylamine and mobile phase 90:10 phospate buffer (pH 4.5) to methanol. A diode array spectrophotometric detector facilitated method development allowing chromatograms to be obtained for range of wavelengths. A linear calibration curve was obtained in range 0-50 μg/ml with correlation coefficient of 0.999 and detection limit was 1.5 μg/ml and relative standard deviation was 1.8% for ten samples at 10μg/ml.(Author)

  6. Thin-layer chromatography coupled with high performance liquid chromatography for determining tetrabromobisphenol A/S and their derivatives in soils.

    Science.gov (United States)

    Liu, Aifeng; Shen, Zhaoshuang; Tian, Yong; Shi, Rongguang; Liu, Yi; Zhao, Zongshan; Xian, Mo

    2017-12-01

    As brominated flame retardants (BFRs), tetrabromobisphenol A/S (TBBPA/S) and their derivatives have raised wide concerns owing to their widely usage, distributions and adverse effects on human health, thus monitoring these BFRs was urgently needed. In this study, a rapid and cost-effective method based on thin-layer chromatography (TLC) sample pre-treatment coupled with high performance liquid chromatography-diode array detector (HPLC-DAD) (UV=214nm) was developed for determining TBBPA/S and their derivatives in soils, including TBBPA, TBBPA bis(allyl ether) (TBBPA-BAE), TBBPA bis(2,3-dibromopropyl ether) (TBBPA-BDBPE), TBBPS bis(allyl ether) (TBBPS-BAE) and TBBPS bis(2,3-dibromopropyl ether) (TBBPS-BDBPE). The method detection limits (MDLs) and the method quantification limits (MQLs) for these BFRs ranged from 0.023 to 0.087μgg -1 dw and 0.076-0.29μgg -1 dw, respectively. The recoveries were 41-108% and both RSD of repeatability and intermediate precision were less than 11%. The developed method presented good performance for analyzing natural soil samples collected from BFRs industrial park, suggesting its great application potential for monitoring environmental TBBPA/S and their derivatives. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. High-Performance Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Vestal, Marvin L.

    1984-01-01

    Reviews techniques for online coupling of high-performance liquid chromatography with mass spectrometry, emphasizing those suitable for application to nonvolatile samples. Also summarizes the present status, strengths, and weaknesses of various techniques and discusses potential applications of recently developed techniques for combined liquid…

  8. Optimisation of high-performance liquid chromatography with diode array detection using an automatic peak tracking procedure based on augmented iterative target transformation factor analysis

    NARCIS (Netherlands)

    van Zomeren, Paul; Hoogvorst, A.; Coenegracht, P.M J; de Jong, G.J.

    2004-01-01

    An automated method for the optimisation of high-performance liquid chromatography is developed. First of all, the sample of interest is analysed with various eluent compositions. All obtained data are combined into one augmented data matrix. Subsequently, augmented iterative target transformation

  9. High perfomance liquid chromatography in pharmaceutical analyses.

    Science.gov (United States)

    Nikolin, Branko; Imamović, Belma; Medanhodzić-Vuk, Saira; Sober, Miroslav

    2004-05-01

    compounds often present in concentrations much greater than those of analyte. Analiyte concentrations are often low, and in the case of drugs, the endogenous compounds are sometimes structurally very similar to the drug to be measured. The binding of drugs to the plasma protein also may occur which decreases the amount of free compound that is measured. To undertake the analyses of drugs and metabolites in body fluids the analyst is facet with several problems. The first problem is due to the complex nature of the body fluid, the drugs must be isolated by an extraction technique, which ideally should provide a relatively clean extract, and the separation system must be capable of resolving the drugs of interest from co extractives. All mentioned when we are using high performance liquid chromatography require good selections of detectors, good stationary phase, eluents and adequate program during separation. UV/VIS detector is the most versatile detector used in high performance liquid chromatography it is not always ideal since it is lack of specificity means high resolution of the analyte that may be required. UV detection is preferred since it offers excellent linearity and rapid quantitative analyses can be performed against a single standard of the drug being determined. Diode array and rapid scanning detector are useful for peak identification and monitoring peak purity but they are somewhat less sensitive then single wavelength detectors. In liquid chromatography some components may have a poor UV chromophores if UV detection is being used or be completely retained on the liquid chromatography column. Fluorescence and electrochemical detector are not only considerably more sensitive towed appropriate analytes but also more selective than UV detectors for many compounds. If at all possible fluorescence detectors are sensitive, stable, selective and easy to operate. It is selectivity shows itself in the lack of frontal components observed in plasma extract whereas

  10. Determination of Phenolic Content in Different Barley Varieties and Corresponding Malts by Liquid Chromatography-diode Array Detection-Electrospray Ionization Tandem Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Daniel O. Carvalho

    2015-08-01

    Full Text Available A simple and reliable method for the simultaneous determination of nine phenolic compounds in barley and malted barley was established, using liquid chromatography-diode array detection-electrospray ionization tandem mass spectrometry (HPLC-DAD-ESI-MS/MS. The phenolic compounds can be easily detected with both systems, despite significant differences in sensitivity. Concentrations approximately 180-fold lower could be achieved by mass spectrometry analysis compared to diode array detection, especially for the flavan-3-ols (+-catechin and (−-epicatechin, which have poor absorptivity in the UV region. Malt samples were characterized by higher phenolic content comparing to corresponding barley varieties, revealing a significant increase of the levels of (+-catechin and (−-epicatechin during the malting process. Moreover, the industrial malting is responsible for modification on the phenolic profile from barley to malt, namely on the synthesis or release of sinapinic acid and epicatechin. Accordingly, the selection of the malting parameters, as well as the barley variety plays an important role when considering the quality and antioxidant stability of beer.

  11. Identification of Ginkgo biloba supplements adulteration using high performance thin layer chromatography and ultra high performance liquid chromatography-diode array detector-quadrupole time of flight-mass spectrometry.

    Science.gov (United States)

    Avula, Bharathi; Sagi, Satyanarayanaraju; Gafner, Stefan; Upton, Roy; Wang, Yan-Hong; Wang, Mei; Khan, Ikhlas A

    2015-10-01

    Ginkgo biloba is one of the most widely sold herbal supplements and medicines in the world. Its popularity stems from having a positive effect on memory and the circulatory system in clinical studies. As ginkgo popularity increased, non-proprietary extracts were introduced claiming to have a similar phytochemical profile as the clinically tested extracts. The standardized commercial extracts of G. biloba leaf used in ginkgo supplements contain not less than 6% sesquiterpene lactones and 24% flavonol glycosides. While sesquiterpene lactones are unique constituents of ginkgo leaf, the flavonol glycosides are found in many other botanical extracts. Being a high value botanical, low quality ginkgo extracts may be subjected to adulteration with flavonoids to meet the requirement of 24% flavonol glycosides. Chemical analysis by ultra high performance liquid chromatography-mass spectrometry revealed that adulteration of ginkgo leaf extracts in many of these products is common, the naturally flavonol glycoside-rich extract being spiked with pure flavonoids or extracts made from another flavonoid-rich material, such as the fruit/flower of Japanese sophora (Styphnolobium japonicum), which also contains the isoflavone genistein. Recently, genistein has been proposed as an analytical marker for the detection of adulteration of ginkgo extracts with S. japonicum. This study confirms that botanically authenticated G. biloba leaf and extracts made therefrom do not contain genistein, and the presence of which even in trace amounts is suggestive of adulteration. In addition to the mass spectrometric approach, a high performance thin layer chromatography method was developed as a fast and economic method for chemical fingerprint analysis of ginkgo samples.

  12. High-performance liquid chromatography of oligoguanylates at high pH

    Science.gov (United States)

    Stribling, R.; Deamer, D. (Principal Investigator)

    1991-01-01

    Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.

  13. Radioactivity monitor for high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Reeve, D.R.; Crozier, A.

    1977-01-01

    The coupling of a homogeneous radioactivity monitor to a liquid chromatograph involves compromises between the sensitivity of the monitor and the resolution and speed of analysis of the chromatograph. The theoretical relationships between these parameters are considered and expressions derived which make it possible to calculate suitable monitor operating conditions for most types of high-performance liquid chromatography

  14. Microcystin Detection Characteristics of Fluorescence Immunochromatography and High Performance Liquid Chromatography

    International Nuclear Information System (INIS)

    Pyo, Dong Jin; Park, Geun Young; Choi, Jong Chon; Oh, Chang Suk

    2005-01-01

    Different detection characteristics of fluorescence immunochromatography method and high performance liquid chromatography (HPLC) method for the analysis of cyanobacterial toxins were studied. In particular, low and high limits of detection, detection time and reproducibility and detectable microcystin species were compared when fluorescence immunochromatography method and high performance liquid chromatography method were applied for the detection of microcystin (MC), a cyclic peptide toxin of the freshwater cyanobacterium Microcystis aeruginosa. A Fluorescence immunochromatography assay system has the unique advantages of short detection time and low detection limit, and high performance liquid chromatography detection method has the strong advantage of individual quantifications of several species of microcystins

  15. Home-made online hyphenation of pressurized liquid extraction, turbulent flow chromatography, and high performance liquid chromatography, Cistanche deserticola as a case study.

    Science.gov (United States)

    Song, Qingqing; Li, Jun; Liu, Xiao; Zhang, Yuan; Guo, Liping; Jiang, Yong; Song, Yuelin; Tu, Pengfei

    2016-03-18

    Incompatibility between the conventional pressurized liquid extraction (PLE) devices and high performance liquid chromatography (HPLC) extensively hinders direct and green chemical analysis of herbal materials. Herein, a facile PLE module was configured, and then it was online hyphenated with HPLC via a turbulent flow chromatography (TFC) column. Regarding PLE module, a long PEEK tube (0.13 × 1000 mm) was employed to generate desired pressure (approximately 13.0 MPa) when warm acidic water (70 °C) was delivered as extraction solvent at a high flow rate (2.5 mL/min), and a hollow guard column (3.0 × 4.0 mm) was implemented to hold crude materials. Effluent was collected from the outlet of PEEK tube, concentrated, and subjected onto HPLC coupled with hybrid ion trap-time of flight mass spectrometer to assess the extraction efficiency and also to profile the chemical composition of Cistanche deserticola (CD) that is honored as "Ginseng of the desert". Afterwards, a TFC column was introduced to accomplish online transmission of low molecule weight components from PLE module to HPLC coupled with diode array detection, and two electronic 6-port/2-channel valves were in charge of alternating the whole system between extraction (0-3.0 min) and elution (3.0-35.0 min) phases. Quantitative method was developed and validated for simultaneous determination of eight primary phenylethanoid glycosides in CD using online PLE-TFC-HPLC. All findings demonstrated that the home-made platform is advantageous at direct chemical analysis, as well as time-, solvent-, and material-savings, suggesting a robust tool for chemical fingerprinting of herbs. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Microwave-assisted ionic liquid homogeneous liquid-liquid microextraction coupled with high performance liquid chromatography for the determination of anthraquinones in Rheum palmatum L.

    Science.gov (United States)

    Wang, Zhibing; Hu, Jianxue; Du, Hongxia; He, Shuang; Li, Qing; Zhang, Hanqi

    2016-06-05

    The microwave-assisted ionic liquid homogeneous liquid-liquid microextraction (MA-IL-HLLME) coupled with high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones, including aloe-emodin, emodin, chrysophanol and physcion in root of Rheum palmatum L. Several experimental parameters influencing the extraction efficiency, including amount of sample, type and volume of ionic liquid, volume and pH value of extraction medium, microwave power and extraction time, concentration of NH4PF6 as well as centrifugal condition were optimized. When 140μL of ionic liquid ([C8MIM][BF4]) was used as an extraction solvent, target analytes can be extracted from sample matrix in one minute with the help of microwave irradiation. The MA-IL-HLLME is simple and quick. The calibration curves exhibited good linear relationship (r>0.9984). The limits of detection and quantification were in the range of 0.015-0.026 and 0.051-0.088μgmL(-1), respectively. The spiked recovery for each analyte was in the range of 81.13-93.07% with relative standard deviations lower than 6.89%. The present method is free of volatile organic solvents, and represents lower expenditures of sample, extraction time and solvent, compared with ultrasonic and heat reflux extraction. The results indicated that the present method can be successfully applied to the determination of anthraquinones in medicinal plant. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. [Analysis of microalbuminuria with immunonephelometry and high performance liquid chromatography. Evaluation of new criteria].

    Science.gov (United States)

    Markó, Lajos; Molnár, Gergo Attila; Wagner, Zoltán; Koszegi, Tamás; Matus, Zoltán; Mohás, Márton; Kuzma, Mónika; Szijártó, István András; Wittmann, István

    2008-01-13

    Hypertension as well as type 2 diabetes mellitus is a major factor in population mortality. Both diseases damage the endothelium, the early sign of which is microalbuminuria, which can be screened by dipstick and can be diagnosed by using immuno-based and high performance liquid chromatography methods. Using high performance liquid chromatography, the non-immunoreactive albumin can be detected as well. The authors aimed at the examination of albuminuria in the case of immunonephelometrically negative patients with high performance liquid chromatography, in diabetic and hypertensive and non-diabetic hypertensive populations. The authors also wanted to compare the present (albumin-creatinine ratio: male: > or =2.5 mg/mmol, female: > or =3.5 mg/mmol) and a new criteria of the Heart Outcomes Prevention Evaluation study (patients without diabetes: immunological method, > or =0.7 mg/mmol; high performance liquid chromatography, > or =3.1 mg/mmol; individuals with diabetes: immunological method, > or =1.4 mg/mmol; high performance liquid chromatography, > or =5.2 mg/mmol) of microalbuminuria. Examination of fresh urines of 469 microalbuminuria negative patients by dipstick were performed by immunonephelometry. Patients, who were microalbuminuria negative by immunonephelometry as well, were further analyzed by high performance liquid chromatography using the Accumintrade mark Kit, based on size-exclusion chromatography. Three times higher albuminuria were found with high performance liquid chromatography than with immunonephelometry. The intraindividual coefficient of variation did not differ in the two methods (37 +/- 31% vs. 40 +/- 31%, p = 0.869; immunonephelometry vs. high performance liquid chromatography; mean +/- standard deviation). Using the present criteria for microalbuminuria, 43% of immunonephelometrically negative patients proved to be microalbuminuric by high performance liquid chromatography. Using the new criteria of the Heart Outcomes Prevention

  18. Study on transfer rule of chemical constituents of tianshu capsule in productive process by high-performance liquid chromatography coupled with diode-array detection and quadrupole time-of-flight tandem mass spectrometry

    International Nuclear Information System (INIS)

    Lian, Y.P.; Xie, D.W.; Li, Y.J.; Xiao, W.; Huang, W.Z.; Ding, G.

    2016-01-01

    To develop a sensitive and accurate method for the fingerprint study and transfer rule of chemical constituents from Ligusticum chuanxiong Hort and Gastrodia elata Blume to Tianshu capsule in productive process, a high performance liquid chromatography coupled with diode-array detection and electrospray ionization quadrupole time-of-flight mass spectrometry (LC/QTOF-MS) method was established for analysis. The reference fingerprints of aqueous extract intermediate of medicinal material, alcohol extract intermediate of medicinal material and Tianshu capsule was established. The methodology was studied and the similarity was more than 0.99. The chromatographic methods demonstrated a good precision, repeatability, stability, with relative standard deviations of less than 3 percent for relative retention time and relative peak area. According to these fingerprints, some chemical constituents in the fingerprints were identified or tentatively identified based on their retention time, exact molecular weight and literature. Among of them 26 constituents were from Ligusticum chuanxiong Hort and nine components were from Gastrodia elata Blume. 25 out of 26 compounds had entered a transfer process and 17 compounds were transferred from intermediates to the final preparation, the Tianshu capsule. Thus, it is reasonable enough to use this transfer process to demonstrate the production technology. To sum up, this method is sensitive, accurate and useful,and it could provide us an approach to evaluate the production technology of Tianshu capsule. (author)

  19. Combined use of liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) and high performance liquid chromatography with photodiode array detector (HPLC-DAD) in systematic toxicological analysis.

    Science.gov (United States)

    Broecker, Sebastian; Pragst, Fritz; Bakdash, Abdulsallam; Herre, Sieglinde; Tsokos, Michael

    2011-10-10

    Time of flight mass spectrometry provides new possibilities of substance identification by determination of the molecular formula from accurate molecular mass and isotope pattern. However, the huge number of possible isomers requires additional evidence. As a suitable way for routine performance of systematic toxicological analysis, a method for combined use of liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) and high performance liquid chromatography with diode array detector (HPLC-DAD) was developed and applied to blood samples from 77 death cases. The blood samples were prepared by extraction with CH(2)Cl(2) and by protein precipitation with acetonitrile (1:4 (v/v)). The evaporated extracts were reconstituted in 35% acetonitril/0.1% formic acid/H(2)O and aliquots were injected for analysis by LC-QTOF-MS (Agilent 6530) and HPLC-DAD (Agilent 1200). A valve switching system enabled simultaneous operation of both separated chromatographic lines under their respective optimal conditions using the same autosampler. The ESI-QTOF-MS instrument was run in data dependent acquisition mode with switching between MS and MS/MS (cycle time 1.1s) and measuring the full mass spectra and the collision induced dissociation (CID) fragment spectra of all essential [M+H](+) ions. Libraries of accurate mass CID spectra (~2500 substances) and of DAD-UV spectra (~3300 substances) of the authors were used for substance identification. The application of this procedure is demonstrated in detail at four examples with multiple drug intake or administration. In the 77 cases altogether 198 substances were identified (87 by DAD and 195 by QTOF-MS) with a frequency between 1 and 20. In practical application, the sample preparation proved to be suitable for both techniques and for a wide variety of substances with different polarity. The automatic performance of the measurements was efficient and robust. Mutual confirmation, decrease of false positive and

  20. Analysis of Theobromine and Related Compounds by Reversed Phase High-Performance Liquid Chromatography with Ultraviolet Detection: An Update (1992–2011

    Directory of Open Access Journals (Sweden)

    Sandra Aparecida de Assis

    2011-01-01

    Full Text Available Theobromine and its related compounds, such as caffeine and theophylline, are secondary metabolites that belong to the alkaloids and have economic and cultural importance. These alkaloids have demonstrated stimulatory effects on the central nervous, gastrointestinal, cardiovascular, renal and respiratory systems, resulting in 'energy arousal', increased motivation to work, increased alertness and increased cognitive function. Several analytical methods have been used to analyse these compounds, but reversed phase high-performance liquid chromatography (RP-HPLC is the most commonly applied because of its efficiency, sensitivity, specificity and speed. This review describes the analyses of theobromine-related compounds by RP-HPLC with ultraviolet detection (UV in four sources: food, beverages, biological fluids and plants. Many RP-HPLC methods have been developed and optimized for the detection and quantification of these natural compounds. Elution under isocratic conditions is the most frequent method, with a water, methanol and acetonitrile mixture modified with acetic, phosphoric or formic acid as the mobile phase. For xanthine analysis, the use of reversed phase high-performance liquid chromatography with an ultraviolet/diode array detector (UV/DAD is particularly suitable as derivation is not required; it allows the analysis of absorbance at all wavelengths, it is simple and rapid.

  1. Evaluation of phenolic compounds in virgin olive oil by direct injection in high-performance liquid chromatography with fluorometric detection.

    Science.gov (United States)

    Selvaggini, Roberto; Servili, Maurizio; Urbani, Stefania; Esposto, Sonia; Taticchi, Agnese; Montedoro, GianFrancesco

    2006-04-19

    Hydrophilic phenols are the most abundant natural antioxidants of virgin olive oil (VOO), in which tocopherols and carotenes are also present. The prevalent classes of hydrophilic phenols found in VOO are phenyl alcohols, phenolic acids, secoiridoids such as the dialdehydic form of decarboxymethyl elenolic acid linked to (3,4-dihydroxyphenyl)ethanol or (p-hydroxypheny1)ethanol (3,4-DHPEA-EDA or p-HPEA-EDA) and an isomer of the oleuropein aglycon (3,4-DHPEA-EA), lignans such as (+)-1-acetoxypinoresinol and (+)-pinoresinol, and flavonoids. A new method for the analysis of VOO hydrophilic phenols by direct injection in high-performance liquid chromatography (HPLC) with the use of a fluorescence detector (FLD) has been proposed and compared with the traditional liquid-liquid extraction technique followed by the HPLC analysis utilizing a diode array detector (DAD) and a FLD. Results show that the most important classes of phenolic compounds occurring in VOO can be evaluated using HPLC direct injection. The efficiency of the new method, as compared to the liquid-liquid extraction, was higher to quantify phenyl alcohols, lignans, and 3,4-DHPEA-EA and lower for the evaluation of 3,4-DHPEA-EDA and p-HPEA-EDA.

  2. Ultra-high Performance Liquid Chromatography in Steroid Analysis

    OpenAIRE

    Salonen, Fanny

    2017-01-01

    The latest version of liquid chromatography is ultra-high performance (or pressure) chromatography (UHPLC). In the technique, short and narrow-bore columns with particle sizes below 3 µm are used. The extremely high pressure used results in very short analysis times, excellent separation, and good resolution. This makes UHPLC a good choice for steroidal analysis. Steroids are a highly interesting area of study; they can be recognized as biomarkers for several diseases and are a relevant topic...

  3. Simultaneous determination of five major compounds in the traditional medicine Pyeongwee-San by high performance liquid chromatography-diode array detection and liquid chromatography-mass spectrometry/mass spectrometry.

    Science.gov (United States)

    Lee, Bohyoung; Weon, Jin Bae; Yun, Bo-Ra; Lee, Jiwoo; Eom, Min Rye; Ma, Choong Je

    2014-01-01

    Pyeongwee-San (PWS) has been widely used for treating acute gastritis, chronic, and gastritis. In this paper, simultaneous determination of five compounds (naringin, hesperidin, glycyrrhizin, atractylenolide III, and magnolol) from traditional medicine PWS using the high performance liquid chromatography (HPLC) was established for quality control. Optimum separations were obtained with a SHISEIDO C18 reverse-phase column by gradient elution with 0.1% Trifluoroacetic acid (TFA) water-acetonitrile as the mobile phase. The flow rate was 1 mL/min and detection wavelength was set at 205 nm and 250 nm. Validation of the analytical method was evaluated by linearity, precision, and accuracy test. The calibration curves were linear over the established range with R (2) > 0.9978. The limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.09 to 0.43 and 0.27 to 1.29 μg/mL. The method exhibited intra-day and inter-day precision range between 0.01-1.86% and 0.04-0.35% respectively. The recoveries of five compounds in PWS were in the range between 93.18-106.40%, and 0.20-1.51%. The application of this method was identified through the successful analysis of five compounds in 12 batches of PWS. In addition, identification of five compounds was confirmed by a liquid chromatography method and mass spectrometry. The HPLC method was could be accomplished to the quality control and stable experiment for the preparations consisted of five major compounds.

  4. Carotenoid content and in vitro bioaccessibility of lycopene from guava (Psidium guajava) and watermelon (Citrullus lanatus) by high-performance liquid chromatography diode array detection.

    Science.gov (United States)

    Chandrika, U G; Fernando, K S S P; Ranaweera, K K D S

    2009-11-01

    The carotenoid content and in vitro accessibility of the 'Sugar baby' variety of watermelon and the 'Horana red' variety of guava from Sri Lanka was determined using high-performance liquid chromatography. The high-performance liquid chromatography chromatogram showed that the Guava 'Horana red' variety contained almost exclusively lycopene (45.3 +/- 8.0 microg/g fresh weight (FW)), with a small amount of lutein (2.1 +/- 0.6 microg/g FW), beta-carotene (2.0 +/- 0.2 microg/g FW) and beta-cryptoxanthin. As far as carotenoids in the sugar baby variety of watermelon are concerned, it contained lycopene, lutein and beta-carotene of 37.2 +/- 4.0 microg/g FW, 2.1 +/- 0.6 microg/g FW and 0.3 +/- 1 microg/g FW, respectively. The studies showed that guava contains more lycopene (45.3+/-8.0 microg/g FW) than watermelon (37.2 +/- 4.0 microg/g FW), and that the in vitro accessibility of lycopene in guava (73%) is more than that in watermelon (25.8%). Therefore it can be concluded that guava can be used as a better lycopene source than watermelon.

  5. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid chromatography (HPLC) method for the determination of cefadroxil monohydrate in human plasma. Methods: Schimadzu HPLC with LC solution software was used with Waters Spherisorb, C18 (5 μm, 150mm × 4.5mm) column. The mobile phase ...

  6. Computer-aided method for identification of major flavone/flavonol glycosides by high-performance liquid chromatography-diode array detection-tandem mass spectrometry (HPLC-DAD-MS/MS).

    Science.gov (United States)

    Wang, Zhengfang; Lin, Longze; Harnly, James M; Harrington, Peter de B; Chen, Pei

    2014-11-01

    A new computational tool is proposed here for tentatively identifying major (UV quantifiable) flavone/flavonol glycoside peaks of high performance liquid chromatogram (HPLC)-diode array detection (DAD)-tandem mass spectrometry (MS/MS) profiles based on a MATLAB-based script implementing an in-house algorithm. The HPLC-DAD-MS/MS profiles of red onion, Chinese lettuce, carrot leaf, and celery seed extracts were analyzed by the proposed computer-aided screening method for identifying possible flavone/flavonol glycoside peaks from the HPLC-UV and MS total ion current (TIC) chromatograms. The number of identified flavone/flavonol glycoside peaks of the HPLC-UV chromatograms is four, four, six, and nine for red onion, Chinese lettuce, carrot leaf, and celery seed, respectively. These results have been validated by human(s) experts. For the batch processing of nine HPLC-DAD-MS/MS profiles of celery seed extract, the entire script execution time was within 15 s while manual calculation of only one HPLC-DAD-MS/MS profile by a flavonoid expert could take hours. Therefore, this MATLAB-based screening method is able to facilitate the HPLC-DAD-MS/MS analysis of flavone/flavonol glycosides in plants to a large extent.

  7. Sensitive characterization of polyphenolic antioxidants in Polygonatum odoratum by selective solid phase extraction and high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Hu, Xin; Zhao, Huading; Shi, Shuyun; Li, Hui; Zhou, Xiaoling; Jiao, Feipeng; Jiang, Xinyu; Peng, Dongming; Chen, Xiaoqin

    2015-08-10

    The complexity of natural products always leads to the co-elution of interfering compounds with bioactive compounds, which then has a detrimental effect on structural elucidation. Here, a new method, based on selective solid phase extraction combined with 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) spiking and high performance liquid chromatography-diode array detector-quadrupole time-of-flight tandem mass spectrometry (HPLC-DAD-QTOF-MS/MS), is described for sensitive screening, selective extraction and identification of polyphenolic antioxidants in Polygonatum odoratum. First, 25 polyphenolic antioxidants (1-25) were screened by DPPH spiking with HPLC. Second, polydopamine coated Fe3O4 microspheres (Fe3O4@PDA) were prepared to selectively extract target antioxidants with extraction efficiency from 55% to 100% when the amount of Fe3O4@PDA, extraction time, desorption solvent and time were 10mg, 20 min, acetonitrile, and 5 min. Third, 25 antioxidants (10 cinnamides and 15 homoisoflavanones) were identified by HPLC-DAD-QTOF-MS/MS. Furthermore, the DPPH scavenging activities of purified compounds (IC50, 1.6-32.8 μg/mL) validated the method. Among the identified antioxidants, four of them (12, 13, 18 and 19) were new compounds, four of them (2, 4, 8 and 14) were first obtained from family Liliaceae, five of them (1, 3, 5, 7 and 9) were first reported in genus Polygonatum, while one compound (24) was first identified in this species. The results indicated that the proposed method was an efficient and sensitive approach to explore polyphenolic antioxidants from complex natural products. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Improved performance of high average power semiconductor arrays for applications in diode pumped solid state lasers

    International Nuclear Information System (INIS)

    Beach, R.; Emanuel, M.; Benett, W.; Freitas, B.; Ciarlo, D.; Carlson, N.; Sutton, S.; Skidmore, J.; Solarz, R.

    1994-01-01

    The average power performance capability of semiconductor diode laser arrays has improved dramatically over the past several years. These performance improvements, combined with cost reductions pursued by LLNL and others in the fabrication and packaging of diode lasers, have continued to reduce the price per average watt of laser diode radiation. Presently, we are at the point where the manufacturers of commercial high average power solid state laser systems used in material processing applications can now seriously consider the replacement of their flashlamp pumps with laser diode pump sources. Additionally, a low cost technique developed and demonstrated at LLNL for optically conditioning the output radiation of diode laser arrays has enabled a new and scalable average power diode-end-pumping architecture that can be simply implemented in diode pumped solid state laser systems (DPSSL's). This development allows the high average power DPSSL designer to look beyond the Nd ion for the first time. Along with high average power DPSSL's which are appropriate for material processing applications, low and intermediate average power DPSSL's are now realizable at low enough costs to be attractive for use in many medical, electronic, and lithographic applications

  9. Ultra high performance liquid chromatography of seized drugs

    NARCIS (Netherlands)

    Lurie, I.S.

    2010-01-01

    The primary goal of this thesis is to investigate the use of ultra high performance liquid chromatography (UHPLC) for the analysis of seized drugs. This goal was largely achieved and significant progress was made in achieving improved separation and detection of drugs of forensic interest.

  10. Single-laboratory validation of a high-performance liquid chromatographic-diode array detector-fluorescence detector/mass spectrometric method for simultaneous determination of water-soluble vitamins in multivitamin dietary tablets.

    Science.gov (United States)

    Chen, Pei; Atkinson, Renata; Wolf, Wayne R

    2009-01-01

    The purpose of this study was to develop a single-laboratory validated (SLV) method using high-performance liquid chromatography with different detectors [diode array detector (DAD); fluorescence detector (FLD); and mass spectrometry (MS)] for determination of 7 B-complex vitamins (B1-thiamin, B2-riboflavin, B3-nicotinamide, B6-pyridoxine, B9-folic acid, pantothenic acid, and biotin) and vitamin C in multivitamin/multimineral dietary supplements. The method involves the use of a reversed-phase octadecylsilyl column (4 microm, 250 x 2.0 mm id) and a gradient mobile phase profile. Gradient elution was performed at a flow rate of 0.25 mL/min. After a 5 min isocratic elution at 100% A (0.1% formic acid in water), a linear gradient to 50% A and 50% B (0.1% formic acid in acetonitrile) at 15 min was employed. Detection was performed with a DAD as well as either an FLD or a triple-quadrupole MS detector in the multiple reaction monitoring mode. SLV was performed using Standard Reference Material (SRM) 3280 Multivitamin/Multimineral Tablets, being developed by the National Institute of Standards and Technology, with support by the Office of Dietary Supplements of the National Institutes of Health. Phosphate buffer (10 mM, pH 2.0) extracts of the NIST SRM 3280 were analyzed by the liquid chromatographic (LC)-DAD-FLDIMS method. Following extraction, the method does not require any sample cleanup/preconcentration steps except centrifugation and filtration.

  11. Mallow carotenoids determined by high-performance liquid chromatography

    Science.gov (United States)

    Mallow (corchorus olitorius) is a green vegetable, which is widely consumed either fresh or dry by Middle East population. This study was carried out to determine the contents of major carotenoids quantitatively in mallow, by using a High Performance Liquid Chromatography (HPLC) equipped with a Bis...

  12. Application of Fourier transform near-infrared spectroscopy combined with high-performance liquid chromatography in rapid and simultaneous determination of essential components in crude Radix Scrophulariae.

    Science.gov (United States)

    Li, Xiaomeng; Fang, Dansi; Cong, Xiaodong; Cao, Gang; Cai, Hao; Cai, Baochang

    2012-12-01

    A method is described using rapid and sensitive Fourier transform near-infrared spectroscopy combined with high-performance liquid chromatography-diode array detection for the simultaneous identification and determination of four bioactive compounds in crude Radix Scrophulariae samples. Partial least squares regression is selected as the analysis type and multiplicative scatter correction, second derivative, and Savitzky-Golay filter were adopted for the spectral pretreatment. The correlation coefficients (R) of the calibration models were above 0.96 and the root mean square error of predictions were under 0.028. The developed models were applied to unknown samples with satisfactory results. The established method was validated and can be applied to the intrinsic quality control of crude Radix Scrophulariae.

  13. performance liquid chromatography

    African Journals Online (AJOL)

    user

    2010-11-22

    Nov 22, 2010 ... ISSN 1684–5315 © 2010 Academic Journals. Full Length Research Paper. Determination ... Key words: Processed food, high-performance liquid chromatography, acrylamide, health hazard. INTRODUCTION. In the year 2002, the ... potatoes, breakfast cereals etc. It was thus confirmed that acrylamide has ...

  14. Analysis of short-chain acids from anaerobic bacteria by high-performance liquid chromatography.

    OpenAIRE

    Guerrant, G O; Lambert, M A; Moss, C W

    1982-01-01

    A standard mixture of 25 short-chain fatty acids was resolved by high-performance liquid chromatography, using an Aminex HPX-87 column. The acids produced in culture media by anaerobic bacteria were analyzed by high-performance liquid chromatography after extraction with ether and reextraction into a small volume of 0.1 N NaOH. The presence of fumaric acid in culture extracts of Peptostreptococcus anaerobius was confirmed by gas chromatography-mass spectrometry analysis of the trapped eluent ...

  15. Pressurized planar electrochromatography, high-performance thin-layer chromatography and high-performance liquid chromatography--comparison of performance.

    Science.gov (United States)

    Płocharz, Paweł; Klimek-Turek, Anna; Dzido, Tadeusz H

    2010-07-16

    Kinetic performance, measured by plate height, of High-Performance Thin-Layer Chromatography (HPTLC), High-Performance Liquid Chromatography (HPLC) and Pressurized Planar Electrochromatography (PPEC) was compared for the systems with adsorbent of the HPTLC RP18W plate from Merck as the stationary phase and the mobile phase composed of acetonitrile and buffer solution. The HPLC column was packed with the adsorbent, which was scrapped from the chromatographic plate mentioned. An additional HPLC column was also packed with adsorbent of 5 microm particle diameter, C18 type silica based (LiChrosorb RP-18 from Merck). The dependence of plate height of both HPLC and PPEC separating systems on flow velocity of the mobile phase and on migration distance of the mobile phase in TLC system was presented applying test solute (prednisolone succinate). The highest performance, amongst systems investigated, was obtained for the PPEC system. The separation efficiency of the systems investigated in the paper was additionally confirmed by the separation of test component mixture composed of six hormones. 2010 Elsevier B.V. All rights reserved.

  16. Rapid screening of transferrin-binders in the flowers of Bauhinia blakeana Dunn by on-line high-performance liquid chromatography-diode-array detector-electrospray ionization-ion-trap-time-of-flight-mass spectrometry-transferrin-fluorescence detection system.

    Science.gov (United States)

    Liu, Meixian; Dong, Jing; Lin, Zongtao; Niu, Yanyan; Zhang, Xiaotian; Jiang, Haixiu; Guo, Ning; Li, Wei; Wang, Hong; Chen, Shizhong

    2016-06-10

    Transferrin (Transferrin, TRF, TF) has drawn increasing attention in cancer therapy due to its potential applications in drug delivery. TF receptor, highly expressed in tumor cells, recognizes and transports Fe(3+)-TF into cells to release iron into cytoplasm. Thus, discovering TF-binding compounds has become an active research area and is of great importance for target therapy. In this study, an on-line analysis method was established for screening TF-binding compounds from the flowers of Bauhinia blakeana Dunn using a high-performance liquid chromatography-diode-array detector-multi-stage mass spectrometry-transferrin-fluorescence detector (HPLC-DAD-MS(n)-TF-FLD) method. As a result, 33 of 80 identified or tentatively characterized compounds in the sample were TF-binding active. Twenty-five flavonol glycosides and eight phenolic acids were identified as TF-binders. Twelve of these active compounds together with six standard compounds were used to study the dose-response effects and structure-activity relationships of flavonoids and phenolic acids. The method was validated by vitexin with a good linearity in the range of concentrations used in the study. The limit of detection for vitexin was 0.1596 nmol. Our study indicated that the established method is simple, rapid and sensitive for screening TF-binding active compounds in the extract of Bauhinia blakeana Dunn, and therefore is important for discovering potential anti-cancer ingredients from complex samples for TF related drug delivery. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Development and validation of carbofuran and 3-hydroxycarbofuran analysis by high-pressure liquid chromatography with diode array detector (HPLC-DAD) for forensic Veterinary Medicine.

    Science.gov (United States)

    Gonçalves, Vagner; Hazarbassanov, Nicolle Queiroz; de Siqueira, Adriana; Florio, Jorge Camilo; Ciscato, Claudia Helena Pastor; Maiorka, Paulo Cesar; Fukushima, André Rinaldi; de Souza Spinosa, Helenice

    2017-10-15

    Agricultural pesticides used with the criminal intent to intoxicate domestic and wild animals are a serious concern in Veterinary Medicine. In order to identify the pesticide carbofuran and its metabolite 3- hydroxycarbofuran in animals suspected of exogenous intoxication a high pressure liquid chromatography with diode array detector (HPLC-DAD) method was developed and validated in stomach contents, liver, vitreous humor and blood. The method was evaluated using biological samples from seven different animal species. The following parameters of analytical validation were evaluated: linearity, precision, accuracy, selectivity, recovery and matrix effect. The method was linear at the range of 6.25-100μg/mL and the correlation coefficient (r 2 ) values were >0.9811 for all matrices. The precision and accuracy of the method was determined by coefficient of variation (CV) and the relative standard deviation error (RSE), and both were less than 15%. Recovery ranged from 74.29 to 100.1% for carbofuran and from 64.72 to 100.61% for 3-hydroxycarbofuran. There were no significant interfering peaks or matrix effects. This method was suitable for detecting 25 positive cases for carbofuran amongst a total of 64 animal samples suspected of poisoning brought to the Toxicology Diagnostic Laboratory, School of Veterinary Medicine and Animal Sciences, University of Sao Paulo. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Instrumentation: Photodiode Array Detectors in UV-VIS Spectroscopy. Part II.

    Science.gov (United States)

    Jones, Dianna G.

    1985-01-01

    A previous part (Analytical Chemistry; v57 n9 p1057A) discussed the theoretical aspects of diode ultraviolet-visual (UV-VIS) spectroscopy. This part describes the applications of diode arrays in analytical chemistry, also considering spectroelectrochemistry, high performance liquid chromatography (HPLC), HPLC data processing, stopped flow, and…

  19. Quantification of Quercetin and Rutin from Benincasa hispida Seeds and Carissa Congesta Roots by High-performance Thin Layer Chromatography and High-performance Liquid Chromatography.

    Science.gov (United States)

    Doshi, Gaurav Mahesh; Une, Hemant Devidas

    2016-01-01

    In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida.

  20. Quantification of Quercetin and Rutin from Benincasa hispida Seeds and Carissa Congesta Roots by High-performance Thin Layer Chromatography and High-performance Liquid Chromatography

    Science.gov (United States)

    Doshi, Gaurav Mahesh; Une, Hemant Devidas

    2016-01-01

    Objective: In Indian Ayurvedic system, Benincasa hispida (BH) and Carissa congesta (CC) are well-known plants used for major and minor ailments. BH has been regarded as Kushmanda, whereas CC has been used in immune-related disorders of the human system. Quercetin and rutin identified from the vast plethora of plant extracts have proved to possess ethnopharmacological relevance. Materials and Methods: In present studies, we have determined quercetin and rutin in terms of percentage in BH seeds and CC roots by high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC). After extraction and phytochemical screening, the extracts were subjected to quantification for the presence of quercetin and rutin by HPTLC and HPLC. Results: HPTLC showed quercetin as 44.60, 27.13% and rutin as 32.00, 36.31% w/w, whereas HPLC revealed quercetin as 34.00, 35.00% and rutin as 21.99, 45.03% w/v in BH and CC extracts, respectively. Conclusion: The BH and CC extracts have elucidated peaks that were corresponding with standard peaks on undertaking chromatographic studies. SUMMARY Quercetin and rutin are isolated from BH seeds and CC roots by High Performance. Thin Layer Chromatography and High Performance Liquid Chromatography. HPTLC revealed presence of quercetin as 44.60, 27.13 % and rutin as 32.00, 36.31 % w/w. HPLC revealed presence of quercetin as 34.00, 35.00 % and rutin as 21.99, 45.03 % w/v. Abbreviation Used: HPTLC: High Performance Thin Layer Chromatography; HPLC: High Pressure Liquid Chromatography, UV: Ultraviolet, CC: Carissa congesta, BH: Benincasa hispida PMID:26941534

  1. Comparison of two extraction procedures for determination of drugs of abuse in human saliva by high-performance liquid chromatography.

    Science.gov (United States)

    Fernández, P; Morales, L; Vázquez, C; Lago, M; Bermejo, A M

    2008-11-01

    High performance liquid chromatography in combination with diode array detection (HPLC-DAD) was used to determine morphine, 6-acetylmorphine, cocaine, benzoylecgonine, cocaethylene, methadone and 2-ethylene-1,5-dimethyl-3,3,-diphenylpyrrolidine in human saliva. For comparison, samples were prepared by either liquid-liquid extraction in Toxitubes A or microwave-assisted extraction (MAE), by mixing 1 ml of saliva with 10 ml of chloroform and operating at 100 degrees C for 10 min. Acetonitrile and 0.02 m phosphate buffer at pH 6.5 were used as mobile phase in HPLC in gradient mode. The detector response was linear over the drug concentration range of 0.05-2.0 microg ml(-1) in human saliva. The analytical method was validated by determining its precision and accuracy (n = 5), which were lower than 5% as relative standard deviation and 6% as relative error. Limits of detection ranged from 10 to 35 ng ml(-1); mean recoveries of drugs were from 53 to 95% with Toxitubes A and from 83 to 100% with MAE at two different concentrations (0.1 and 1.0 microg ml(-1)). The proposed method was applied to 24 saliva samples from individuals poisoned with opiates and/or cocaine.

  2. Fractionation of fecal neutral steroids by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Jackson, E.M.; Kloss, C.A.; Weintraub, S.T.; Mott, G.E.

    1985-01-01

    Fecal neutral steroids were fractionated by high performance liquid chromatography (HPLC) into three major fractions: 5 beta-H, 3-keto steroids; 5 beta-H, 3 beta-hydroxy steroids; and 5 alpha-H and delta 5-3 beta-hydroxy steroids. This separation was achieved in about 10 minutes, with greater than 97% recovery of standards in each fraction. Gas-liquid chromatographic quantitation of fecal steroids fractionated by either HPLC or thin-layer chromatography gave nearly identical results. A method using both C18 reverse phase and silica HPLC to purify radiolabeled sterols is also described

  3. Monitoring aged reversed-phase high performance liquid chromatography columns

    NARCIS (Netherlands)

    Bolck, A; Smilde, AK; Bruins, CHP

    1999-01-01

    In this paper, a new approach for the quality assessment of routinely used reversed-phase high performance liquid chromatography columns is presented. A used column is not directly considered deteriorated when changes in retention occur. If attention is paid to the type and magnitude of the changes,

  4. Combined high-performance liquid chromatography/32P-postlabeling assay of N7-methyldeoxyguanosine

    International Nuclear Information System (INIS)

    Shields, P.G.; Povey, A.C.; Wilson, V.L.; Weston, A.; Harris, C.C.

    1990-01-01

    A highly sensitive and specific assay for the detection of N7-methyl-2'-deoxyguanosine (N7methyldG) has been developed by combining high-performance liquid chromatography, 32 P-postlabeling, and nucleotide chromatography. Separation of normal nucleotides and adducts by high-performance liquid chromatography and then combining a portion of 2'-deoxyguanosine to the N7methyldG allows for quantitation using an internal standard. The directly determined molar ratio is not subject to errors in digestion, variable ATP-specific activity, or assumptions in relative adduct-labeling efficiency. The detection limit was one N7methyldG adduct in 10(7) unmodified 2'-deoxyguanosine bases. N7methyldG adducts have been detected in 5 human lung samples in which O6-methyl-2'-deoxyguanosine adducts had been previously determined. The mean ratio of N7methyldG to O6-methyl-2'-deoxyguanosine was determined to be approximately 10. The current assay complements the high-performance liquid chromatography/ 32 P-postlabeling assay for O6-methyl-2'-deoxyguanosine and increases the detection sensitivity of DNA methylated by exogenous alkylating agents

  5. Liquid chromatography with diode array detection and multivariate curve resolution for the selective and sensitive quantification of estrogens in natural waters.

    Science.gov (United States)

    Pérez, Rocío L; Escandar, Graciela M

    2014-07-04

    Following the green analytical chemistry principles, an efficient strategy involving second-order data provided by liquid chromatography (LC) with diode array detection (DAD) was applied for the simultaneous determination of estriol, 17β-estradiol, 17α-ethinylestradiol and estrone in natural water samples. After a simple pre-concentration step, LC-DAD matrix data were rapidly obtained (in less than 5 min) with a chromatographic system operating isocratically. Applying a second-order calibration algorithm based on multivariate curve resolution with alternating least-squares (MCR-ALS), successful resolution was achieved in the presence of sample constituents that strongly coelute with the analytes. The flexibility of this multivariate model allowed the quantification of the four estrogens in tap, mineral, underground and river water samples. Limits of detection in the range between 3 and 13 ng L(-1), and relative prediction errors from 2 to 11% were achieved. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Performance measurements of hybrid PIN diode arrays

    International Nuclear Information System (INIS)

    Jernigan, J.G.; Arens, J.F.; Collins, T.; Herring, J.; Shapiro, S.L.; Wilburn, C.D.

    1990-05-01

    We report on the successful effort to develop hybrid PIN diode arrays and to demonstrate their potential as components of vertex detectors. Hybrid pixel arrays have been fabricated by the Hughes Aircraft Co. by bump bonding readout chips developed by Hughes to an array of PIN diodes manufactured by Micron Semiconductor Inc. These hybrid pixel arrays were constructed in two configurations. One array format having 10 x 64 pixels, each 120 μm square, and the other format having 256 x 256 pixels, each 30 μm square. In both cases, the thickness of the PIN diode layer is 300 μm. Measurements of detector performance show that excellent position resolution can be achieved by interpolation. By determining the centroid of the charge cloud which spreads charge into a number of neighboring pixels, a spatial resolution of a few microns has been attained. The noise has been measured to be about 300 electrons (rms) at room temperature, as expected from KTC and dark current considerations, yielding a signal-to-noise ratio of about 100 for minimum ionizing particles. 4 refs., 13 figs

  7. Quantification of Tea Flavonoids by High Performance Liquid Chromatography

    Science.gov (United States)

    Freeman, Jessica D.; Niemeyer, Emily D.

    2008-01-01

    We have developed a laboratory experiment that uses high performance liquid chromatography (HPLC) to quantify flavonoid levels in a variety of commercial teas. Specifically, this experiment analyzes a group of flavonoids known as catechins, plant-derived polyphenolic compounds commonly found in many foods and beverages, including green and black…

  8. Dispersive liquid-liquid microextraction for the determination of vitamins D and K in foods by liquid chromatography with diode-array and atmospheric pressure chemical ionization-mass spectrometry detection.

    Science.gov (United States)

    Viñas, Pilar; Bravo-Bravo, María; López-García, Ignacio; Hernández-Córdoba, Manuel

    2013-10-15

    A simple and rapid method was developed using reversed-phase liquid chromatography (LC) with both diode array (DAD) and atmospheric pressure chemical ionization mass spectrometric (APCI-MS) detection, for the simultaneous analysis of the vitamins ergocalciferol (D2), cholecalciferol (D3), phylloquinone (K1), menaquinone-4 (K2) and a synthetic form of vitamin K, menadione (K3). The Taguchi experimental method, an orthogonal array design (OAD), was used to optimize an efficient and clean preconcentration step based on dispersive liquid-liquid microextraction (DLLME). A factorial design was applied with six factors and three levels for each factor, namely, carbon tetrachloride volume, methanol volume, aqueous sample volume, pH of sample, sodium chloride concentration and time of the centrifugation step. The DLLME optimized procedure consisted of rapidly injecting 3 mL of acetonitrile (disperser solvent) containing 150 µL carbon tetrachloride (extraction solvent) into the aqueous sample, thereby forming a cloudy solution. Phase separation was performed by centrifugation, and the sedimented phase was evaporated with nitrogen, reconstituted with 50 µL of acetonitrile, and injected. The LC analyses were carried out using a mobile phase composed of acetonitrile, 2-propanol and water, under gradient elution. Quantification was carried out by the standard additions method. The APCI-MS spectra, in combination with UV spectra, permitted the correct identification of compounds in the food samples. The method was validated according to international guidelines and using a certified reference material. The validated method was applied for the analysis of vitamins D and K in infant foods and several green vegetables. There was little variability in the forms of vitamin K present in vegetables, with the most abundant vitamer in all the samples being phylloquinone, while menadione could not be detected. Conversely, cholecalciferol, which is present in food of animal origin, was

  9. Determination of Flavonoids and Anthocyanins in Nitraria tangutorum by High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry.

    Science.gov (United States)

    Zhe, Gao; Ying-Chun, Wang; Yan-Xu, Chang

    2016-01-01

    Using high-performance liquid chromatography coupled with diode array detection and electrospray ionization tandem mass spectrometry (HPLC-DAD-MSn) method, qualitative and quantitative analysis of flavonoids of stems, leaves, fruits and seeds, and anthocyanidin of fresh fruits in Nitraria tangutorum were performed. A total of 14 flavonoid components were identified from the seeds of N. tangutorum including three quercetin derivatives, three kaempferol derivatives, and eight isorhamnetin derivatives. A total of 12, 10, and 7 flavonoid components were identified from leaves, stems, and fruits of N. tangutorum, respectively; all were present in seeds also. The total content of flavonoids in leaves was the highest, up to 42.43 mg/g·dry weight. A total of 12 anthocyanidin components were identified from the fresh fruits of N. tangutorum, belonging to five anthocyanidin. The total content of anthocyanidin in fresh fruits was up to 45.83 mg/100 g· fresh weight, of which the acylated anthocyanidin accounted for 65.7%. The HPLC-DAD-MS(n) method can be operated easily, rapidly, and accurately, and is feasible for qualitative and quantitative analysis of flavone glycosides in N. tangutorum.

  10. Combined high-performance liquid chromatography-radioimmunoassay for cytokinins

    International Nuclear Information System (INIS)

    MacDonald, E.M.S.; Akiyoshi, D.E.; Morris, R.O.

    1981-01-01

    The cytokinins isopentenyladenosine and ribosylzeatin were conjugated to bovine serum albumin and the conjugates used to raise antisera in rabbits. The resulting antisera had high specificity towards the cytokinin haptens and low cross-reactivity towards other purines. They were used as the basis for a radioimmunoassay for cytokinins, which, when applied in conjunction with high-performance liquid chromatography, allowed rapid and sensitive (to the picogram range) estimation and identification of multiple cytokinins from natural plant and bacterial sources. (orig.)

  11. High-Performance Liquid Chromatography in the Undergraduate Chemical Engineering Laboratory

    Science.gov (United States)

    Frey, Douglas D.; Guo, Hui; Karnik, Nikhila

    2013-01-01

    This article describes the assembly of a simple, low-cost, high-performance liquid chromatography (HPLC) system and its use in the undergraduate chemical engineering laboratory course to perform simple experiments. By interpreting the results from these experiments students are able to gain significant experience in the general method of…

  12. Application of Ionic Liquids in High Performance Reversed-Phase Chromatography

    Directory of Open Access Journals (Sweden)

    Wentao Bi

    2009-06-01

    Full Text Available Ionic liquids, considered “green” chemicals, are widely used in many areas of analytical chemistry due to their unique properties. Recently, ionic liquids have been used as a kind of novel additive in separation and combined with silica to synthesize new stationary phase as separation media. This review will focus on the properties and mechanisms of ionic liquids and their potential applications as mobile phase modifier and surface-bonded stationary phase in reversed-phase high performance liquid chromatography (RP-HPLC. Ionic liquids demonstrate advantages and potential in chromatographic field.

  13. Determination of Caffeine in Beverages by High Performance Liquid Chromatography.

    Science.gov (United States)

    DiNunzio, James E.

    1985-01-01

    Describes the equipment, procedures, and results for the determination of caffeine in beverages by high performance liquid chromatography. The method is simple, fast, accurate, and, because sample preparation is minimal, it is well suited for use in a teaching laboratory. (JN)

  14. High-Performance Liquid Chromatography (HPLC)-Based Detection and Quantitation of Cellular c-di-GMP.

    Science.gov (United States)

    Petrova, Olga E; Sauer, Karin

    2017-01-01

    The modulation of c-di-GMP levels plays a vital role in the regulation of various processes in a wide array of bacterial species. Thus, investigation of c-di-GMP regulation requires reliable methods for the assessment of c-di-GMP levels and turnover. Reversed-phase high-performance liquid chromatography (RP-HPLC) analysis has become a commonly used approach to accomplish these goals. The following describes the extraction and HPLC-based detection and quantification of c-di-GMP from Pseudomonas aeruginosa samples, a procedure that is amenable to modifications for the analysis of c-di-GMP in other bacterial species.

  15. Evaluation between ultrahigh pressure liquid chromatography and high-performance liquid chromatography analytical methods for characterizing natural dyestuffs.

    Science.gov (United States)

    Serrano, Ana; van Bommel, Maarten; Hallett, Jessica

    2013-11-29

    An evaluation was undertaken of ultrahigh pressure liquid chromatography (UHPLC) in comparison to high-performance liquid chromatography (HPLC) for characterizing natural dyes in cultural heritage objects. A new UHPLC method was optimized by testing several analytical parameters adapted from prior UHPLC studies developed in diverse fields of research. Different gradient elution programs were tested on seven UHPLC columns with different dimensions and stationary phase compositions by applying several mobile phases, flow rates, temperatures, and runtimes. The UHPLC method successfully provided more improved data than that achieved by the HPLC method. Indeed, even though carminic acid has shown circa 146% higher resolution with HPLC, UHPLC resulted in an increase of 41-61% resolution and a decrease of 91-422% limit of detection, depending on the dye compound. The optimized method was subsequently assigned to analyse 59 natural reference materials, in which 85 different components were ascribed with different physicochemical properties, in order to create a spectral database for future characterization of dyes in cultural heritage objects. The majority of these reference samples could be successfully distinguished with one single method through the examination of these compounds' retention times and their spectra acquired with a photodiode array detector. These results demonstrate that UHPLC analyses are extremely valuable for the acquisition of more precise chromatographic information concerning natural dyes with complex mixtures of different and/or closely related physicochemical properties, essential for distinguishing similar species of plants and animals used to colour cultural heritage objects. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Antibiofilm activity of cashew juice pulp against Staphylococcus aureus, high performance liquid chromatography/diode array detection and gas chromatography-mass spectrometry analyses, and interference on antimicrobial drugs

    Directory of Open Access Journals (Sweden)

    Marcus V. Dias-Souza

    2017-07-01

    Full Text Available The epidemiology of Staphylococcus aureus infections has evolved in recent years, as this species is a major Gram-positive pathogen associated with healthcare services. The antimicrobial resistance of this species raises an urgent need for new treatment strategies. Fruits play important nutritional and economic roles in society, but their biological and pharmacological features are poorly explored when compared to nonedible parts of plants such as barks and leaves. In this study, we show that the cashew apple juice [cashew juice pulp (CJP] extract is active against the planktonic cells of S. aureus strains, and for the first time, we show that CJP is also active against S. aureus biofilms. High performance liquid chromatography and gas chromatography-mass spectrometry analyses were conducted to prospect for polyphenols and free carbohydrates, respectively. Cashew apple juice, which is rich in nutrients, is widely consumed in Brazil; therefore, the quality attributes of CJPs were investigated. Samples were evaluated for pH, total titratable acidity, vitamin C levels, and total soluble solids. We also detected an antagonistic interference of CJP when it was combined with different antimicrobial drugs.

  17. Assay for dihydroorotase using high-performance liquid chromatography with radioactivity detection

    International Nuclear Information System (INIS)

    Mehdi, S.; Wiseman, J.S.

    1989-01-01

    An assay for measuring dihydroorotase activity was devised. Radiolabeled substrate and product were separated by high-performance liquid chromatography using a reverse-phase column with ion-pairing, and the radioactivity was quantitated by flow detection

  18. Characterisation of homoflavonoids from three Ophioglossum species using liquid chromatography with diode array detection and electrospray ionisation tandem mass spectrometry.

    Science.gov (United States)

    Wan, Chuan-Xing; Luo, Jian-Guang; Gu, Yu-Cheng; Xu, De-Ran; Kong, Ling-Yi

    2013-01-01

    Homoflavonoids, characterised by one more carbon atom directly added to C6 -C3 -C6 backbone of flavonoids, are rich in the species of genus Ophioglossum. Up to now we have little knowledge about their MS fragmentation patterns. It is therefore necessary to investigate their MS fragmentation pathways so as to distinguish them from other types of flavonoids. To develop a rapid method for identifying homoflavonoids from Ophioglossum based on their characteristic MS fragmentation. Mass spectrometry fragmentation pathways and qualitative analysis of homoflavonoids in three ferns of Ophioglosssum were investigated by using high-performance liquid chromatography coupled with diode-array detection and electrospray ionisation tandem mass spectrometry (HPLC-DAD-ESI/MS(n) ). The analyses of the MS(n) spectra of the homoflavonoids allowed us to classify them into two types according to their fragmentation characteristics. The type I homoflavonoids, with an attached additional carbon atom to the C-3 position of the C-ring, presented the initial competing loss of H2 O and CH2 O from their aglycone ions, compared to the initial removal of H2 O or CO in the case of the type II homoflavonoids, which bear the additional carbon atom at the C-2' site of the B-ring and forming ring D. The above characteristic fragmentations of homoflavonoids were quite different from those of other flavonoids, and were successfully applied to identify homoflavonoids in the crude extracts of three Ophioglossum species. The HPLC-DAD-ESI/MS(n) method obtained in the present study provided a powerful tool for identifying homoflavonoids from ferns in the genus Ophioglossum. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Characterization of natural organic colorants in historical and art objects by high-performance liquid chromatography.

    Science.gov (United States)

    Pauk, Volodymyr; Barták, Petr; Lemr, Karel

    2014-12-01

    High-performance liquid chromatography plays an important role in analysis of historical organic colorants. A number of papers have been published in this field over the last 30 years. Classification of the most commonly used natural dyes and an overview of high-performance liquid chromatography methods with main focus on recent works (2008 to the beginning of 2014) are provided. The review deals with an entire analytical protocol covering sample preparation, chromatographic separation, and suitable detection (UV/visible and fluorescent spectroscopy and mass spectrometric techniques). High-performance liquid chromatography has been successfully used in the complete characterization of some organic dyestuffs present in historical and art objects. The possibilities and difficulties for identification of natural sources of historical colorants are also discussed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Application of Silver Ion High-Performance Liquid Chromatography for Quantitative Analysis of Selected n-3 and n-6 PUFA in Oil Supplements.

    Science.gov (United States)

    Czajkowska-Mysłek, Anna; Siekierko, Urszula; Gajewska, Magdalena

    2016-04-01

    The aim of this study was to develop a simple method for simultaneous determination of selected cis/cis PUFA-LNA (18:2), ALA (18:3), GLA (18:3), EPA (20:5), and DHA (22:6) by silver ion high-performance liquid chromatography coupled to a diode array detector (Ag-HPLC-DAD). The separation was performed on three Luna SCX Silver Loaded columns connected in series maintained at 10 °C with isocratic elution by 1% acetonitrile in n-hexane. The applied chromatographic system allowed a baseline separation of standard mixture of n-3 and n-6 fatty acid methyl esters containing LNA, DHA, and EPA and partial separation of ALA and GLA positional isomers. The method was validated by means of linearity, precision, stability, and recovery. Limits of detection (LOD) for considered PUFA standard solutions ranged from 0.27 to 0.43 mg L(-1). The developed method was used to evaluate of n-3 and n-6 fatty acids contents in plant and fish softgel oil capsules, results were compared with reference GC-FID based method.

  1. Separation of enantiomers of new psychoactive substances by high-performance liquid chromatography.

    Science.gov (United States)

    Kadkhodaei, Kian; Forcher, Lisa; Schmid, Martin G

    2018-03-01

    New psychoactive substances are defined as compounds with consciousness-changing effects and have been developed simultaneously with classical drugs. They arise through structural modifications of illegal substances and are mainly produced to circumvent laws. Availability is simple, since new psychoactive substances can be purchased from the Internet. Among them many chemical drug compound classes are chiral and thus the two resulting enantiomers can differ in their effects. The aim of this study is to develop a suitable chiral high-performance liquid chromatography separation method for a broad spectrum of new psychoactive substances using cellulose tris(3,5-dichlorophenylcarbamate) as a chiral selector. Experiments were performed by high-performance liquid chromatography in normal-phase mode under isocratic conditions using ultraviolet detection. Direct separation was carried out on a high-performance liquid chromatography column (Lux® i-Cellulose-5, 3.5 μm, Phenomenex®), available since 2016. Excellent separation results were obtained for cathinones. After further optimization, even 47 instead of 39 out of 52 cathinones showed baseline separation. For amphetamine derivatives, satisfactory results were not achieved. Further, new psychoactive substances from other compound classes such as benzofuranes, thiophenes, phenidines, phenidates, morpholines, and ketamines were partially resolved, depending on the polarity and degree of substitution. All analytes, which were mainly purchased from the Internet, were proven to be traded as racemates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Chemical profiling approach to evaluate the influence of traditional and simplified decoction methods on the holistic quality of Da-Huang-Xiao-Shi decoction using high-performance liquid chromatography coupled with diode-array detection and time-of-flight mass spectrometry.

    Science.gov (United States)

    Yan, Xuemei; Zhang, Qianying; Feng, Fang

    2016-04-01

    Da-Huang-Xiao-Shi decoction, consisting of Rheum officinale Baill, Mirabilitum, Phellodendron amurense Rupr. and Gardenia jasminoides Ellis, is a traditional Chinese medicine used for the treatment of jaundice. As described in "Jin Kui Yao Lue", a traditional multistep decoction of Da-Huang-Xiao-Shi decoction was required while simplified one-step decoction was used in recent repsorts. To investigate the chemical difference between the decoctions obtained by the traditional and simplified preparations, a sensitive and reliable approach of high-performance liquid chromatography coupled with diode-array detection and electrospray ionization time-of-flight mass spectrometry was established. As a result, a total of 105 compounds were detected and identified. Analysis of the chromatogram profiles of the two decoctions showed that many compounds in the decoction of simplified preparation had changed obviously compared with those in traditional preparation. The changes of constituents would be bound to cause the differences in the therapeutic effects of the two decoctions. The present study demonstrated that certain preparation methods significantly affect the holistic quality of traditional Chinese medicines and the use of a suitable preparation method is crucial for these medicines to produce special clinical curative effect. This research results elucidated the scientific basis of traditional preparation methods in Chinese medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Measuring levels of biogenic amines and their metabolites in rat brain tissue using high-performance liquid chromatography with photodiode array detection.

    Science.gov (United States)

    Gu, Min-Jung; Jeon, Ji-Hyun; Oh, Myung Sook; Hong, Seon-Pyo

    2016-01-01

    We developed a method to detect biogenic amines and their metabolites in rat brain tissue using simultaneous high-performance liquid chromatography and a photodiode array detection. Measurements were made using a Hypersil Gold C-18 column (250 × 2.1 mm, 5 µm). The mobile phase was 5 mM perchloric acid containing 5 % acetonitrile. The correlation coefficient was 0.9995-0.9999. LODs (S/N = 3) and LOQs (S/N = 10) were as follows: dopamine 0.4 and 1.3 pg, 3, 4-dihydroxyphenylacetic acid 8.4 and 28.0 pg, serotonin 0.4 and 1.3 pg, 5-hydroxyindolacetic acid 3.4 and 11.3 pg, and homovanillic acid 8.4 and 28.0 pg. This method does not require derivatization steps, and is more sensitive than the widely used HPLC-UV method.

  4. Assessing the detectability of antioxidants in two-dimensional high-performance liquid chromatography.

    Science.gov (United States)

    Bassanese, Danielle N; Conlan, Xavier A; Barnett, Neil W; Stevenson, Paul G

    2015-05-01

    This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods--the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Screening anti-tumor compounds from Ligusticum wallichii using cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry.

    Science.gov (United States)

    Zhang, Tao; Ding, Yuanyuan; An, Hongli; Feng, Liuxin; Wang, Sicen

    2015-07-14

    Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry was developed. Tyrosine 367 Cysteine-HEK293 cells were used as cell membrane stationary phase. Specificity and reproducibility of the cell membrane chromatography was evaluated using 1-tert-butyl-3-{2-[4-(diethylamino)butylamino]-6-(3,5-dimethoxyphenyl)pyrido[2,3-d]pyrimidin-7-yl}urea, Nimodipine and dexamethasone acetate. Then, anti-tumor components acting on Tyrosine 367 Cysteine-fibroblast growth factor receptor 4 were screened and identified from extracts of Ligusticum wallichii. Components from the extract were retained on the cell membrane chromatographic column. The retained fraction was directly eluted into high-performance liquid chromatography with mass spectrometry system for separation and identification. Finally, Levistolide A was identified as an active component from Ligusticum wallichii extracts. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide-formazan colorimetric assay revealed that Levistolide A inhibits proliferation of overexpressing the mutated receptor cells with dose-dependent manner. Phosphorylation of fibroblast growth factor receptor 4 was also decrease under Levistolide A treatment. Flex dock simulation verified that Levistolide A could bind with the tyrosine kinase domain of fibroblast growth factor receptor 4. Therefore, Levistolide A screened by the cell membrane chromatography combined with high-performance liquid chromatography and mass spectrometry can arrest cell growth. In conclusion, the two-dimensional high-performance liquid chromatography method can screen and identify potential anti-tumor ingredients which specifically act on the tyrosine kinase domain of the mutated fibroblast growth factor receptor 4. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. High performance liquid chromatography in studies of radiolabeled antibodies

    International Nuclear Information System (INIS)

    Hnatowich, D.J.

    1986-01-01

    High performance liquid chromatography (HPLC) as applied to the separation of antibodies displays the same advantages as in its other applications, namely good resolution accompanied by fast analysis. It is therefore not surprising that many HPLC columns designed for use with antibodies and other proteins are now available commercially. The properties of proteins which provide the separation are size, hydrophobicity, charge and affinity. The features of each are discussed. (author)

  7. A new ultrahigh performance liquid chromatography with diode array detection coupled to electrospray ionization and quadrupole time-of-flight mass spectrometry analytical strategy for fast analysis and improved characterization of phenolic compounds in apple products.

    Science.gov (United States)

    Ramirez-Ambrosi, M; Abad-Garcia, B; Viloria-Bernal, M; Garmon-Lobato, S; Berrueta, L A; Gallo, B

    2013-11-05

    A new, rapid, selective and sensitive ultrahigh performance liquid chromatography with diode array detection coupled to electrospray ionization and quadrupole time-of-flight mass spectrometry (UHPLC-DAD-ESI-Q-ToF-MS) strategy using automatic and simultaneous acquisition of exact mass at high and low collision energy, MS(E), has been developed to obtain polyphenolic profile of apples, apple pomace and apple juice from Asturian cider apples in a single run injection of 22 min. MS(E) spectral data acquisition overcomes chromatographic co-elution problems, performing simultaneous collection of precursor ions as well as other ions produced as a result of their fragmentation, which allows resolving complex spectra from mixtures of precursor ions in an unsupervised way and eases their interpretation. Using this technique, 52 phenolic compounds of five different classes were readily characterized in these apple extracts in both positive and negative ionization modes. The spectral data for phenolic compounds obtained using this acquisition mode are comparable to those obtained by conventional LC-MS/MS as exemplified in this work. Among the 52 phenolic compounds identified in this work, 2 dihydrochalcones and 3 flavonols have been tentatively identified for the first time in apple products. Moreover, 2 flavanols, 4 dihydrochalcones, 9 hydroxycinnamic acids and 4 flavonols had not been previously reported in apple by ToF analysis to our knowledge. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. High Performance Liquid Chromatography Experiments to Undergraduate Laboratories

    Science.gov (United States)

    Kissinger, Peter T.; And Others

    1977-01-01

    Reviews the principles of liquid chromatography with electrochemical detection (LCEC), an analytical technique that incorporates the advantages of both liquids chromatography and electrochemistry. Also suggests laboratory experiments using this technique. (MLH)

  9. Analysis of quaternary ammonium and phosphonium ionic liquids by reversed-phase high-performance liquid chromatography with charged aerosol detection and unified calibration.

    Science.gov (United States)

    Stojanovic, Anja; Lämmerhofer, Michael; Kogelnig, Daniel; Schiesel, Simone; Sturm, Martin; Galanski, Markus; Krachler, Regina; Keppler, Bernhard K; Lindner, Wolfgang

    2008-10-31

    Several hydrophobic ionic liquids (ILs) based on long-chain aliphatic ammonium- and phosphonium cations and selected aromatic anions were analyzed by reversed-phase high-performance liquid chromatography (RP-HPLC) employing trifluoroacetic acid as ion-pairing additive to the acetonitrile-containing mobile phase and adopting a step-gradient elution mode. The coupling of charged aerosol detection (CAD) for the non-chromophoric aliphatic cations with diode array detection (DAD) for the aromatic anions allowed their simultaneous analysis in a set of new ILs derived from either tricaprylmethylammonium chloride (Aliquat 336) and trihexyltetradecylphosphonium chloride as precursors. Aliquat 336 is a mix of ammonium cations with distinct aliphatic chain lengths. In the course of the studies it turned out that CAD generates an identical detection response for all the distinct aliphatic cations. Due to lack of single component standards of the individual Aliquat 336 cation species, a unified calibration function was established for the quantitative analysis of the quaternary ammonium cations of the ILs. The developed method was validated according to ICH guidelines, which confirmed the validity of the unified calibration. The application of the method revealed molar ratios of cation to anion close to 1 indicating a quantitative exchange of the chloride ions of the precursors by the various aromatic anions in the course of the synthesis of new ILs. Anomalies of CAD observed for the detection of some aromatic anions (thiosalicylate and benzoate) are discussed.

  10. [Analysis of the preservative chlorphenesin in cosmetics by high performance liquid chromatography].

    Science.gov (United States)

    Zhu, Huijuan; Zhang, Weiqiang; Yang, Yanwei; Zhu, Ying

    2014-01-01

    An analytical method was developed for the determination of the preservative of chlorphenesin in cosmetics by high performance liquid chromatography (HPLC). A C18 column (250 mm x 4.6 mm, 5 microm) and a photodiode array detector were used. The mobile phase was methanol-water (55:45, v/v) with a flow rate of 1.0 mL/min. The detection wavelength was set at 280 nm and the column temperature was 25 degrees C. The limit of detection was 3 ng. A good linear relationship was obtained between the peak area and the mass concentration of chlorphenesin in the range of 1 - 500 mg/L and the correlation coefficient was 1.000 0. The recoveries of chlorphenesin at different spiked levels were 99.0% - 103% with the relative standard deviations (RSD) chlorphenesin in cosmetics.

  11. Improving Reliability of High Power Quasi-CW Laser Diode Arrays for Pumping Solid State Lasers

    Science.gov (United States)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, Nathaniel R.; Barnes, Bruce W.; Baggott, Renee S.; Lockard, George E.; Singh, Upendra N.; Kavaya, Michael J.

    2005-01-01

    Most Lidar applications rely on moderate to high power solid state lasers to generate the required transmitted pulses. However, the reliability of solid state lasers, which can operate autonomously over long periods, is constrained by their laser diode pump arrays. Thermal cycling of the active regions is considered the primary reason for rapid degradation of the quasi-CW high power laser diode arrays, and the excessive temperature rise is the leading suspect in premature failure. The thermal issues of laser diode arrays are even more drastic for 2-micron solid state lasers which require considerably longer pump pulses compared to the more commonly used pump arrays for 1-micron lasers. This paper describes several advanced packaging techniques being employed for more efficient heat removal from the active regions of the laser diode bars. Experimental results for several high power laser diode array devices will be reported and their performance when operated at long pulsewidths of about 1msec will be described.

  12. Chromatographic behavior of small organic compounds in low-temperature high-performance liquid chromatography using liquid carbon dioxide as the mobile phase.

    Science.gov (United States)

    Motono, Tomohiro; Nagai, Takashi; Kitagawa, Shinya; Ohtani, Hajime

    2015-07-01

    Low-temperature high-performance liquid chromatography, in which a loop injector, column, and detection cell were refrigerated at -35ºC, using liquid carbon dioxide as the mobile phase was developed. Small organic compounds (polyaromatic hydrocarbons, alkylbenzenes, and quinones) were separated by low-temperature high-performance liquid chromatography at temperatures from -35 to -5ºC. The combination of liquid carbon dioxide mobile phase with an octadecyl-silica (C18 ) column provided reversed phase mode separation, and a bare silica-gel column resulted in normal phase mode separation. In both the cases, nonlinear behavior at approximately -15ºC was found in the relationship between the temperature and the retention factors of the analytes (van't Hoff plots). In contrast to general trends in high-performance liquid chromatography, the decrease in temperature enhanced the separation efficiency of both the columns. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry for arsenic speciation.

    Science.gov (United States)

    Cheng, Heyong; Shen, Lihuan; Liu, Jinhua; Xu, Zigang; Wang, Yuanchao

    2018-04-01

    Nanoliter high-performance liquid chromatography shows low consumption of solvents and samples, offering one of the best choices for arsenic speciation in precious samples in combination with inuctively coupled plasma mass spectrometry. A systematic investigation on coupling nanoliter high-performance liquid chromatography to inductively coupled plasma mass spectrometry from instrument design to injected sample volume and mobile phase was performed in this study. Nanoflow mobile phase was delivered by flow splitting using a conventional high-pressure pump with reuse of mobile phase waste. Dead volume was minimized to 60 nL for the sheathless interface based on the previously developed nanonebulizer. Capillary columns for nanoliter high-performance liquid chromatography were found to be sensitive to sample loading volume. An apparent difference was also found between the mobile phases for nanoliter and conventional high-performance liquid chromatography. Baseline separation of arsenite, arsenate, monomethylarsenic, and dimethylarsenic was achieved within 11 min on a 15 cm C 18 capillary column and within 12 min on a 25 cm strong anion exchange column. Detection limits of 0.9-1.8 μg/L were obtained with precisions variable in the range of 1.6-4.2%. A good agreement between determined and certified values of a certified reference material of human urine (GBW 09115) validated its accuracy along with good recoveries (87-102%). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Highly sensitive reversed-phase high-performance liquid chromatography assay for the detection of Tamm-Horsfall protein in human urine.

    Science.gov (United States)

    Akimoto, Masaru; Hokazono, Eisaku; Ota, Eri; Tateishi, Takiko; Kayamori, Yuzo

    2016-01-01

    Tamm-Horsfall protein (also known as uromodulin) is the most abundant urinary protein in healthy individuals. Since initially characterized by Tamm and Horsfall, the amount of urinary excretion and structural mutations of Tamm-Horsfall protein is associated with kidney diseases. However, currently available assays for Tamm-Horsfall protein, which are mainly enzyme-linked immunosorbent assay-based, suffer from poor reproducibility and might give false negative results. We developed a novel, quantitative assay for Tamm-Horsfall protein using reversed-phase high-performance liquid chromatography. A precipitation pretreatment avoided urine matrix interference and excessive sample dilution. High-performance liquid chromatography optimization based on polarity allowed excellent separation of Tamm-Horsfall protein from other major urine components. Our method exhibited high precision (based on the relative standard deviations of intraday [≤2.77%] and interday [≤5.35%] repetitions). The Tamm-Horsfall protein recovery rate was 100.0-104.2%. The mean Tamm-Horsfall protein concentration in 25 healthy individuals was 31.6 ± 18.8 mg/g creatinine. There was a strong correlation between data obtained by high-performance liquid chromatography and enzyme-linked immunosorbent assay (r = 0.906), but enzyme-linked immunosorbent assay values tended to be lower than high-performance liquid chromatography values at low Tamm-Horsfall protein concentrations. The high sensitivity and reproducibility of our Tamm-Horsfall protein assay will reduce the number of false negative results of the sample compared with enzyme-linked immunosorbent assay. Moreover, our method is superior to other high-performance liquid chromatography methods, and a simple protocol will facilitate further research on the physiological role of Tamm-Horsfall protein. © The Author(s) 2015.

  15. Ultra High Performance Liquid Chromatography Method for the Determination of Two Recently FDA Approved TKIs in Human Plasma Using Diode Array Detection

    Directory of Open Access Journals (Sweden)

    Marwa Fouad

    2015-01-01

    Full Text Available Generally, tyrosine kinase inhibitors have narrow therapeutic window and large interpatient variability compared to intrapatient variability. In order to support its therapeutic drug monitoring, two fast and accurate methods were developed for the determination of recently FDA approved anticancer tyrosine kinase inhibitors, afatinib and ibrutinib, in human plasma using ultra high performance liquid chromatography coupled to PDA detection. Diclofenac sodium was used as internal standard. The chromatographic separation was achieved on an Acquity UPLC BEH C18 analytical column using a mobile phase combining ammonium formate buffer and acetonitrile at a constant flow rate of 0.4 mL/min using gradient elution mode. A µSPE (solid phase extraction procedure, using Oasis MCX µElution plates, was processed and it gave satisfying and reproducible results in terms of extraction yields. Additionally, the methods were successfully validated using the accuracy profiles approach (β = 95% and acceptance limits = ±15% over the ranges 5–250 ng/mL for afatinib and from 5 to 400 ng/mL for ibrutinib in human plasma.

  16. Extraction of three bioactive diterpenoids from Andrographis paniculata: effect of the extraction techniques on extract composition and quantification of three andrographolides using high-performance liquid chromatography.

    Science.gov (United States)

    Kumar, Satyanshu; Dhanani, Tushar; Shah, Sonal

    2014-10-01

    Andrographis paniculata (Burm.f.) wall.ex Nees (Acanthaceae) or Kalmegh is an important medicinal plant finding uses in many Ayurvedic formulations. Diterpenoid compounds andrographolides (APs) are the main bioactive phytochemicals present in leaves and herbage of A. paniculata. The efficiency of supercritical fluid extraction (SFE) using carbon dioxide was compared with the solid-liquid extraction techniques such as solvent extraction, ultrasound-assisted solvent extraction and microwave-assisted solvent extraction with methanol, water and methanol-water as solvents. Also a rapid and validated reverse-phase high-performance liquid chromatography-diode array detection method was developed for the simultaneous determination of the three biologically active compounds, AP, neoandrographolide and andrograpanin, in the extracts of A. paniculata. Under the best SFE conditions tested for diterpenoids, which involved extraction at 60°C and 100 bar, the extractive efficiencies were 132 and 22 µg/g for AP and neoandrographolide, respectively. The modifier percentage significantly affected the extraction efficiency. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. An Advanced, Interactive, High-Performance Liquid Chromatography Simulator and Instructor Resources

    Science.gov (United States)

    Boswell, Paul G.; Stoll, Dwight R.; Carr, Peter W.; Nagel, Megan L.; Vitha, Mark F.; Mabbott, Gary A.

    2013-01-01

    High-performance liquid chromatography (HPLC) simulation software has long been recognized as an effective educational tool, yet many of the existing HPLC simulators are either too expensive, outdated, or lack many important features necessary to make them widely useful for educational purposes. Here, a free, open-source HPLC simulator is…

  18. Extraction and Purification of Glucoraphanin by Preparative High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Lee, Iris; Boyce, Mary C.

    2011-01-01

    A student activity that focuses on the isolation of glucoraphanin from broccoli using preparative high-performance liquid chromatography (HPLC) is presented here. Glucoraphanin is a glucosinolate, whose byproducts are known to possess anticancer properties. It is present naturally at high levels in broccoli and other "Brassica" vegetables. This…

  19. Sensitive determination of three aconitum alkaloids and their metabolites in human plasma by matrix solid-phase dispersion with vortex-assisted dispersive liquid-liquid microextraction and HPLC with diode array detection.

    Science.gov (United States)

    Wang, Xiaozhong; Li, Xuwen; Li, Lanjie; Li, Min; Liu, Ying; Wu, Qian; Li, Peng; Jin, Yongri

    2016-05-01

    A simple and sensitive method for determination of three aconitum alkaloids and their metabolites in human plasma was developed using matrix solid-phase dispersion combined with vortex-assisted dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection. The plasma sample was directly purified by matrix solid-phase dispersion and the eluate obtained was concentrated and further clarified by vortex-assisted dispersive liquid-liquid microextraction. Some important parameters affecting the extraction efficiency, such as type and amount of dispersing sorbent, type and volume of elution solvent, type and volume of extraction solvent, salt concentration as well as sample solution pH, were investigated in detail. Under optimal conditions, the proposed method has good repeatability and reproducibility with intraday and interday relative standard deviations lower than 5.44 and 5.75%, respectively. The recoveries of the aconitum alkaloids ranged from 73.81 to 101.82%, and the detection limits were achieved within the range of 1.6-2.1 ng/mL. The proposed method offered the advantages of good applicability, sensitivity, simplicity, and feasibility, which makes it suitable for the determination of trace amounts of aconitum alkaloids in human plasma samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Silicon monolithic microchannel-cooled laser diode array

    International Nuclear Information System (INIS)

    Skidmore, J. A.; Freitas, B. L.; Crawford, J.; Satariano, J.; Utterback, E.; DiMercurio, L.; Cutter, K.; Sutton, S.

    2000-01-01

    A monolithic microchannel-cooled laser diode array is demonstrated that allows multiple diode-bar mounting with negligible thermal cross talk. The heat sink comprises two main components: a wet-etched Si layer that is anodically bonded to a machined glass block. The continuous wave (cw) thermal resistance of the 10 bar diode array is 0.032 degree sign C/W, which matches the performance of discrete microchannel-cooled arrays. Up to 1.5 kW/cm 2 is achieved cw at an emission wavelength of ∼808 nm. Collimation of a diode array using a monolithic lens frame produced a 7.5 mrad divergence angle by a single active alignment. This diode array offers high average power/brightness in a simple, rugged, scalable architecture that is suitable for large two-dimensional areas. (c) 2000 American Institute of Physics

  1. Incorporation of ionic liquid into porous polymer monoliths to enhance the separation of small molecules in reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Jiafei; Bai, Ligai; Wei, Zhen; Qin, Junxiao; Ma, Yamin; Liu, Haiyan

    2015-06-01

    An ionic liquid was incorporated into the porous polymer monoliths to afford stationary phases with enhanced chromatographic performance for small molecules in reversed-phase high-performance liquid chromatography. The effect of the ionic liquid in the polymerization mixture on the performance of the monoliths was studied in detail. While monoliths without ionic liquid exhibited poor resolution and low efficiency, the addition of ionic liquid to the polymerization mixture provides highly increased resolution and high efficiency. The chromatographic performances of the monoliths were demonstrated by the separations of various small molecules including aromatic hydrocarbons, isomers, and homologues using a binary polar mobile phase. The present column efficiency reached 27 000 plates/m, which showed that the ionic liquid monoliths are alternative stationary phases in the separation of small molecules by high-performance liquid chromatography. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Separation of hemagglutination-inhibiting immunoglobulin M antibody to rubella virus in human serum by high-performance liquid chromatography.

    OpenAIRE

    Kobayashi, N; Suzuki, M; Nakagawa, T; Matumoto, M

    1986-01-01

    High-performance liquid chromatography was successfully used to separate hemagglutination-inhibiting immunoglobulin M (IgM) rubella virus antibody from IgG rubella virus antibody in human serum. The fractionation by high-performance liquid chromatography was as effective as sucrose density gradient centrifugation in separating IgM antibody from IgG antibody.

  3. Determination of trimethyllead reference material using high performance liquid chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lu Hai; Wei Chao; Wang Jun; Chao Jingbo; Zhou Tao; Chen Dazhou

    2005-01-01

    A high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) was combined, and the chromatography conditions were optimized. The stability and homogeneity of a trimethyllead reference material were determined using this method. (authors)

  4. Comparison of antioxidant activities of different parts from snow chrysanthemum (Coreopsis tinctoria Nutt.) and identification of their natural antioxidants using high performance liquid chromatography coupled with diode array detection and mass spectrometry and 2,2'-azinobis(3-ethylbenzthiazoline-sulfonic acid)diammonium salt-based assay.

    Science.gov (United States)

    Chen, L X; Hu, D J; Lam, S C; Ge, L; Wu, D; Zhao, J; Long, Z R; Yang, W J; Fan, B; Li, S P

    2016-01-08

    Snow chrysanthemum (Coreopsis tinctoria Nutt.), a world-widely well-known flower tea material, has attracted more and more attention because of its beneficial health effects such as antioxidant activity and special flavor. In this study, a high performance liquid chromatography coupled with diode array detection and mass spectrometry (HPLC-DAD-MS) and 2,2'-azinobis(3-ethylbenzthiazoline-sulfonic acid)diammonium salt (ABTS) based assay was employed for comparison and identification of antioxidants in different samples of snow chrysanthemum. The results showed that snow chrysanthemum flowers possessed the highest while stems presented the lowest antioxidant capacities. Fourteen detected peaks with antioxidant activity were temporarily identified as 3,4',5,6,7-pentahydroxyflavanone-O-hexoside, chlorogenic acid, 2R-3',4',8-trihydroxyflavanone-7-O-glucoside, flavanomarein, flavanocorepsin, flavanokanin, quercetagitin-7-O-glucoside, 3',5,5',7-tetrahydroxyflavanone-O-hexoside, marein, maritimein, 1,3-dicaffeoylquinic acid, coreopsin, okanin and acetyl-marein by comparing their UV spectra, retention times and MS data with standards or literature data. Antioxidants existed in snow chrysanthemum are quite different from those reported in Chrysanthemum morifolium, a well-known traditional beverage in China, which indicated that snow chrysanthemum may be a promising herbal tea material with obvious antioxidant activity. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. A high performance liquid chromatography method for determination of furfural in crude palm oil.

    Science.gov (United States)

    Loi, Chia Chun; Boo, Huey Chern; Mohammed, Abdulkarim Sabo; Ariffin, Abdul Azis

    2011-09-01

    A modified steam distillation method was developed to extract furfural from crude palm oil (CPO). The collected distillates were analysed using high performance liquid chromatography (HPLC) coupled with an ultraviolet diode detector at 284nm. The HPLC method allowed identification and quantification of furfural in CPO. The unique thermal extraction of CPO whereby the fresh fruit bunches (FFB) are first subjected to steam treatment, distinguishes itself from other solvent-extracted or cold-pressed vegetable oils. The presence of furfural was also determined in the fresh palm oil from FFB (without undergoing the normal extraction process), palm olein, palm stearin, olive oil, coconut oil, sunflower oil, soya oil and corn oil. The chromatograms of the extracts were compared to that of standard furfural. Furfural was only detected in CPO. The CPO consignments obtained from four mills were shown to contain 7.54 to 20.60mg/kg furfural. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Surface-bonded ionic liquid stationary phases in high-performance liquid chromatography--a review.

    Science.gov (United States)

    Pino, Verónica; Afonso, Ana M

    2012-02-10

    Ionic liquids (ILs) are a class of ionic, nonmolecular solvents which remain in liquid state at temperatures below 100°C. ILs possess a variety of properties including low to negligible vapor pressure, high thermal stability, miscibility with water or a variety of organic solvents, and variable viscosity. IL-modified silica as novel high-performance liquid chromatography (HPLC) stationary phases have attracted considerable attention for their differential behavior and low free-silanol activity. Indeed, around 21 surface-confined ionic liquids (SCIL) stationary phases have been developed in the last six years. Their chromatographic behavior has been studied, and, despite the presence of a positive charge on the stationary phase, they showed considerable promise for the separation of neutral solutes (not only basic analytes), when operated in reversed phase mode. This aspect points to the potential for truly multimodal stationary phases. This review attempts to summarize the state-of-the-art about SCIL phases including their preparation, chromatographic behavior, and analytical performance. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    Science.gov (United States)

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  8. Advancements of ultra-high peak power laser diode arrays

    Science.gov (United States)

    Crawford, D.; Thiagarajan, P.; Goings, J.; Caliva, B.; Smith, S.; Walker, R.

    2018-02-01

    Enhancements of laser diode epitaxy in conjunction with process and packaging improvements have led to the availability of 1cm bars capable of over 500W peak power at near-infrared wavelengths (770nm to 1100nm). Advances in cooler design allow for multi-bar stacks with bar-to-bar pitches as low as 350μm and a scalable package architecture enabled a single diode assembly with total peak powers of over 1MegaWatt of peak power. With the addition of micro-optics, overall array brightness greater than 10kW/cm2 was achieved. Performance metrics of barbased diode lasers specifically engineered for high peak power and high brightness at wavelengths and pulse conditions commonly used to pump a variety of fiber and solid-state materials are presented.

  9. Optimized and validated high-performance liquid chromatography method for the determination of deoxynivalenol and aflatoxins in cereals.

    Science.gov (United States)

    Skendi, Adriana; Irakli, Maria N; Papageorgiou, Maria D

    2016-04-01

    A simple, sensitive and accurate analytical method was optimized and developed for the determination of deoxynivalenol and aflatoxins in cereals intended for human consumption using high-performance liquid chromatography with diode array and fluorescence detection and a photochemical reactor for enhanced detection. A response surface methodology, using a fractional central composite design, was carried out for optimization of the water percentage at the beginning of the run (X1, 80-90%), the level of acetonitrile at the end of gradient system (X2, 10-20%) with the water percentage fixed at 60%, and the flow rate (X3, 0.8-1.2 mL/min). The studied responses were the chromatographic peak area, the resolution factor and the time of analysis. Optimal chromatographic conditions were: X1 = 80%, X2 = 10%, and X3 = 1 mL/min. Following a double sample extraction with water and a mixture of methanol/water, mycotoxins were rapidly purified by an optimized solid-phase extraction protocol. The optimized method was further validated with respect to linearity (R(2) >0.9991), sensitivity, precision, and recovery (90-112%). The application to 23 commercial cereal samples from Greece showed contamination levels below the legally set limits, except for one maize sample. The main advantages of the developed method are the simplicity of operation and the low cost. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Hydrazine Determination in Sludge Samples by High Performance Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    G. Elias; G. A. Park

    2006-02-01

    A high-performance liquid chromatographic method using ultraviolet (UV) detection was developed to detect and quantify hydrazine in a variety of environmental matrices. The method was developed primarily for sludge samples, but it is also applicable to soil and water samples. The hydrazine in the matrices was derivatized to their hydrazones with benzaldehyde. The derivatized hydrazones were separated using high performance liquid chromatography (HPLC) with a reversed-phase C-18 column in an isocratic mode with methanol-water (95:5, v/v), and detected with UV detection at 313 nm. The detection limit (25 ml) for the new analytical method is 0.0067 mg ml-1of hydrazine. Hydrazine showed low recovery in soil samples because components in soil oxidized hydrazine. Sludge samples that contained relatively high soil content also showed lower recovery. The technique is relatively simple and cost-effective, and is applicable for hydrazine analysis in different environmental matrices.

  11. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses

    OpenAIRE

    Suriyavathana Muthukrishnan; Subha Palanisamy; Senthilkumar Subramanian; Sumathi Selvaraj; Kavitha Rani Mari; Ramalingam Kuppulingam

    2016-01-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. Th...

  12. Simultaneous Determination of Procainamide and N-acetylprocainamide in Rat Plasma by Ultra-High-Pressure Liquid Chromatography Coupled with a Diode Array Detector and Its Application to a Pharmacokinetic Study in Rats.

    Science.gov (United States)

    Balla, Anusha; Cho, Kwan Hyung; Kim, Yu Chul; Maeng, Han-Joo

    2018-03-30

    A simple, sensitive, and reliable reversed-phase, Ultra-High-Pressure Liquid Chromatography (UHPLC) coupled with a Diode Array Detector (DAD) method for the simultaneous determination of Procainamide (PA) and its major metabolite, N -acetylprocainamide (NAPA), in rat plasma was developed and validated. A simple deproteinization method with methanol was applied to the rat plasma samples, which were analyzed using UHPLC equipped with DAD at 280 nm, and a Synergi™ 4 µm polar, reversed-phase column using 1% acetic acid (pH 5.5) and methanol (76:24, v / v ) as eluent in isocratic mode at a flow rate 0.2 mL/min. The method showed good linearity ( r ² > 0.998) over the concentration range of 20-100,000 and 20-10,000 ng/mL for PA and NAPA, respectively. Intra- and inter-day accuracies ranged from 97.7 to 110.9%, and precision was HPLC methods is that it requires small sample and injection volumes, with a straightforward, one-step sample preparation. It overcomes the limitations of previous methods, which use large sample volume and complex sample preparation. The devised method was successfully applied to the quantification of PA and NAPA after an intravenous bolus administration of 10 mg/kg procainamide hydrochloride to rats.

  13. Separation of lanthanum from nuclear fuel solutions by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Lazar, G. C.; Petre, M.; Androne, G.; Benga, A.

    2016-01-01

    This paper presents the separation of uranium, praseodymium and lanthanum from nuclear fuel solutions by high performance liquid chromatography (HPLC). The aim of this study is to establish a minimum concentration of lanthanum which can be analyzed by high performance liquid chromatography, and also to study the effect of uranium concentration on the separation of praseodymium and lanthanum. Optimum gradient mode was established for mixture standard stoc solutions with uranium in a concentration of 1 mg/ml, praseodymium and lanthanum in a concentration range of 1-5 μg/ml from each element. These conditions were applied for the separation of lanthanum from a nuclear fuel solution in which praseodymium and lanthanum were added in a concentration of 3 μg/ml from each element. The elution behavior of lanthanum as a function of the pH and the concentration of the mobile phase, using a mixture of 1-octanesulfonic acid sodium salt with a-hidroxyisobutiric acid is presented. (authors)

  14. Determination of phthalates released from paper packaging materials by solid-phase extraction-high-performance liquid chromatography.

    Science.gov (United States)

    Gao, Xin; Yang, Bofeng; Tang, Zhixu; Luo, Xin; Wang, Fengmei; Xu, Hui; Cai, Xue

    2014-01-01

    A solid phase extraction (SPE) high-performance liquid chromatography (HPLC) method was developed for the simultaneous determination of 10 phthalic acid esters (dimethyl phthalate, diethyl phthalate, dipropyl phthalate, benzylbutyl phthalate, diisobutyl phthalate, dicyclohexyl phthalate, diamyl phthalate, di-n-hexyl phthalate, di-n-octyl phthalate and di-2-ethylhexyl phthalate) released from food paper packaging materials. The use of distilled water, 3% acetic acid (w/v), 10% ethanol (v/v) and 95% ethanol (v/v) instead of the different types of food simulated the migration of 10 phthalic acid esters from food paper packaging materials; the phthalic acid esters in four food simulants were enriched and purified by a C18 SPE column and nitrogen blowing, and quantified by HPLC with a diode array detector. The chromatographic conditions and extraction conditions were optimized and all 10 of the phthalate acid esters had a maximum absorbance at 224 nm. The method showed limitations of detection in the range of 6.0-23.8 ng/mL the correlation coefficients were greater than 0.9999 in all cases, recovery values ranged between 71.27 and 106.97% at spiking levels of 30, 60 and 90 ng/mL and relative standard deviation values ranged from 0.86 to 8.00%. The method was considered to be simple, fast and reliable for a study on the migration of these 10 phthalic acid esters from food paper packaging materials into food.

  15. DETECTION AND QUANTIFICATION OF PHYTOCHEMICAL MARKERS OF Ilex paraguariensis BY LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Rodrigo M. C. Pinto

    2015-11-01

    Full Text Available Ilex paraguariensis (yerba-mate is used as a beverage, and its extract requires adequate quality control methods in order to guarantee quality and safe use. Strategies to develop and optimize a chromatographic method to quantify theobromine, caffeine, and chlorogenic acid in I. paraguariensis extracts were evaluated by applying a quality by design (QbD model and ultra high-performance liquid chromatography (UHPLC. The presence of these three phytochemical markers in the extracts was evaluated using UHPLC-MS and was confirmed by the chromatographic bands in the total ion current traces (m/z of 181.1 [M+H]+, 195.0 [M+H]+, and 353.0 [M−H]−, respectively. The developed method was then transferred to a high-performance liquid chromatography (HPLC platform, and the three phytochemical markers were used as external standards in the validation of a method for analyses of these compounds in extracts using a diode array detector (DAD. The validated method was applied to quantify the chlorogenic acid, caffeine, and theobromine in the samples. HPLC-DAD chromatographic fingerprinting was also used in a multivariate approach to process the entire data and to separate the I. paraguariensis extracts into two groups. The developed method is very useful for qualifying and quantifying I. paraguariensis extracts.

  16. Determination of Four Major Saponins in Skin and Endosperm of Seeds of Horse Chestnut (Aesculus Hippocastanum L.) Using High Performance Liquid Chromatography with Positive Confirmation by Thin Layer Chromatography.

    Science.gov (United States)

    Abudayeh, Zead Helmi Mahmoud; Al Azzam, Khaldun Mohammad; Naddaf, Ahmad; Karpiuk, Uliana Vladimirovna; Kislichenko, Viktoria Sergeevna

    2015-11-01

    To separate and quantify four major saponins in the extracts of the skin and the endosperm of seeds of horse chestnut (Aesculus hippocastanum L.) using ultrasonic solvent extraction followed by a high performance liquid chromatography-diode array detector (HPLC-DAD) with positive confirmation by thin layer chromatography (TLC). The saponins: escin Ia, escin Ib, isoescin Ia and isoescin Ib were extracted using ultrasonic extraction method. The optimized extraction conditions were: 70% methanol as extraction solvent, 80 °C as extraction temperature, and the extraction time was achieved in 4 hours. The HPLC conditions used: Zorbax SB-ODS-(150 mm × 2.1 mm, 3 μm) column, acetonitrile and 0.10% phosphoric acid solution (39:61 v/v) as mobile phase, flow rate was 0.5 mL min(-1) at 210 nm and 230 nm detection. The injection volume was 10 μL, and the separation was carried out isothermally at 30 °C in a heated chamber. The results indicated that the developed HPLC method is simple, sensitive and reliable. Moreover, the content of escins in seeds decreased by more than 30% in endosperm and by more than 40% in skin upon storage for two years. This assay can be readily utilized as a quality control method for horse chestnut and other related medicinal plants.

  17. Fast and comprehensive analysis of secondary metabolites in cocoa products using ultra high-performance liquid chromatography directly after pressurized liquid extraction.

    Science.gov (United States)

    Damm, Irina; Enger, Eileen; Chrubasik-Hausmann, Sigrun; Schieber, Andreas; Zimmermann, Benno F

    2016-08-01

    Fast methods for the extraction and analysis of various secondary metabolites from cocoa products were developed and optimized regarding speed and separation efficiency. Extraction by pressurized liquid extraction is automated and the extracts are analyzed by rapid reversed-phase ultra high-performance liquid chromatography and normal-phase high-performance liquid chromatography methods. After extraction, no further sample treatment is required before chromatographic analysis. The analytes comprise monomeric and oligomeric flavanols, flavonols, methylxanthins, N-phenylpropenoyl amino acids, and phenolic acids. Polyphenols and N-phenylpropenoyl amino acids are separated in a single run of 33 min, procyanidins are analyzed by normal-phase high-performance liquid chromatography within 16 min, and methylxanthins require only 6 min total run time. A fourth method is suitable for phenolic acids, but only protocatechuic acid was found in relevant quantities. The optimized methods were validated and applied to 27 dark chocolates, one milk chocolate, two cocoa powders and two food supplements based on cocoa extract. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Characterization of chemical constituents in Rhodiola Crenulate by high-performance liquid chromatography coupled with Fourier-transform ion cyclotron resonance mass spectrometer (HPLC-FT-ICR MS).

    Science.gov (United States)

    Han, Fei; Li, Yanting; Mao, Xinjuan; Xu, Rui; Yin, Ran

    2016-05-01

    In this work, an approach using high-performance liquid chromatography coupled with diode-array detection and Fourier-transform ion cyclotron resonance mass spectrometer (HPLC-FT-ICR MS) for the identification and profiling of chemical constituents in Rhodiola crenulata was developed for the first time. The chromatographic separation was achieved on an Inertsil ODS-3 column (150 mm × 4.6 mm,3 µm) using a gradient elution program, and the detection was performed on a Bruker Solarix 7.0 T mass spectrometer equipped with electrospray ionization source in both positive and negative modes. Under the optimized conditions, a total of 48 chemical compounds, including 26 alcohols and their glycosides, 12 flavonoids and their glycosides, 5 flavanols and gallic acid derivatives, 4 organic acids and 1 cyanogenic glycoside were identified or tentatively characterized. The results indicated that the developed HPLC-FT-ICR MS method with ultra-high sensitivity and resolution is suitable for identifying and characterizing the chemical constituents in R. crenulata. And it provides a helpful chemical basis for further research on R. crenulata. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Preparation and evaluation of surface-bonded tricationic ionic liquid silica as stationary phases for high-performance liquid chromatography.

    Science.gov (United States)

    Qiao, Lizhen; Shi, Xianzhe; Lu, Xin; Xu, Guowang

    2015-05-29

    Two tricationic ionic liquids were prepared and then bonded onto the surface of supporting silica materials through "thiol-ene" click chemistry as new stationary phases for high-performance liquid chromatography. The obtained columns of tricationic ionic liquids were evaluated respectively in the reversed-phase liquid chromatography (RPLC) mode and hydrophilic interaction liquid chromatography (HILIC) mode, and possess ideal column efficiency of 80,000 plates/m in the RPLC mode with naphthalene as the test solute. The tricationic ionic liquid stationary phases exhibit good hydrophobic and shape selectivity to hydrophobic compounds, and RPLC retention behavior with multiple interactions. In the HILIC mode, the retention and selectivity were evaluated through the efficient separation of nucleosides and bases as well as flavonoids, and the typical HILIC retention behavior was demonstrated by investigating retention changes of hydrophilic solutes with water volume fraction in mobile phase. The results show that the tricationic ionic liquid columns possess great prospect for applications in analysis of hydrophobic and hydrophilic samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Identification, characterization, and high-performance liquid chromatography quantification of process-related impurities in vonoprazan fumarate.

    Science.gov (United States)

    Liu, Lei; Cao, Na; Ma, Xingling; Xiong, Kaihe; Sun, Lili; Zou, Qiaogen

    2016-04-01

    High-performance liquid chromatography analysis of vonoprazan fumarate, a novel proton pump inhibitor drug revealed six impurities. These were identified by liquid chromatography with mass spectrometry. Further, the structures of the impurities were confirmed by synthesis followed by characterization by mass spectrometry, NMR spectroscopy, and infrared spectroscopy. On the basis of these data and knowledge of the synthetic scheme of vonoprazan fumarate, the previously unknown impurity was identified as 1-[5-(2-fluorophenyl)-1-(pyridin-3-ylsulfonyl)-1H-pyrrol-3-yl]-N-methyldimethylamine, which is a new compound. The possible mechanisms by which these impurities were formed were also discussed. A high-performance liquid chromatography method was optimized in order to separate, selectively detect, and quantify all process-related impurities of vonoprazan fumarate. The presented method has been validated in terms of linearity, limits of detection, and quantification, and response factors and, therefore, is highly suitable for routine analysis of vonoprazan fumarate related substances as well as stability studies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Utilization of highly robust and selective crosslinked polymeric ionic liquid-based sorbent coatings in direct-immersion solid-phase microextraction and high-performance liquid chromatography for determining polar organic pollutants in waters.

    Science.gov (United States)

    Pacheco-Fernández, Idaira; Najafi, Ali; Pino, Verónica; Anderson, Jared L; Ayala, Juan H; Afonso, Ana M

    2016-09-01

    Several crosslinked polymeric ionic liquid (PIL)-based sorbent coatings of different nature were prepared by UV polymerization onto nitinol wires. They were evaluated in a direct-immersion solid-phase microextraction (DI-SPME) method in combination with high-performance liquid chromatography (HPLC) and diode array detection (DAD). The studied PIL coatings contained either vinyl alkyl or vinylbenzyl imidazolium-based (ViCnIm- or ViBCnIm-) IL monomers with different anions, as well as different dicationic IL crosslinkers. The analytical performance of these PIL-based SPME coatings was firstly evaluated for the extraction of a group of 10 different model analytes, including hydrocarbons and phenols, while exhaustively comparing the performance with commercial SPME fibers such as polydimethylsyloxane (PDMS), polyacrylate (PA) and polydimethylsiloxane/divinylbenzene (PDMS/DVB), and using all fibers under optimized conditions. Those fibers exhibiting a high selectivity for polar compounds were selected to carry out an analytical method for a group of 5 alkylphenols, including bisphenol-A (BPA) and nonylphenol (n-NP). Under optimum conditions, average relative recoveries of 108% and inter-day precision values (3 non-consecutive days) lower than 19% were obtained for a spiked level of 10µgL(-1). Correlations coefficients for the overall method ranged between 0.990 and 0.999, and limits of detection were down to 1µgL(-1). Tap water, river water, and bottled water were analyzed to evaluate matrix effects. Comparison with the PA fiber was also performed in terms of analytical performance. Partition coefficients (logKfs) of the alkylphenols to the SPME coating varied from 1.69 to 2.45 for the most efficient PIL-based fiber, and from 1.58 to 2.30 for the PA fiber. These results agree with those obtained by the normalized calibration slopes, pointing out the affinity of these PILs-based coatings. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. High-performance liquid chromatography separation of unsaturated organic compounds by a monolithic silica column embedded with silver nanoparticles.

    Science.gov (United States)

    Zhu, Yang; Morisato, Kei; Hasegawa, George; Moitra, Nirmalya; Kiyomura, Tsutomu; Kurata, Hiroki; Kanamori, Kazuyoshi; Nakanishi, Kazuki

    2015-08-01

    The optimization of a porous structure to ensure good separation performances is always a significant issue in high-performance liquid chromatography column design. Recently we reported the homogeneous embedment of Ag nanoparticles in periodic mesoporous silica monolith and the application of such Ag nanoparticles embedded silica monolith for the high-performance liquid chromatography separation of polyaromatic hydrocarbons. However, the separation performance remains to be improved and the retention mechanism as compared with the Ag ion high-performance liquid chromatography technique still needs to be clarified. In this research, Ag nanoparticles were introduced into a macro/mesoporous silica monolith with optimized pore parameters for high-performance liquid chromatography separations. Baseline separation of benzene, naphthalene, anthracene, and pyrene was achieved with the theoretical plate number for analyte naphthalene as 36,000 m(-1). Its separation function was further extended to cis/trans isomers of aromatic compounds where cis/trans stilbenes were chosen as a benchmark. Good separation of cis/trans-stilbene with separation factor as 7 and theoretical plate number as 76,000 m(-1) for cis-stilbene was obtained. The trans isomer, however, is retained more strongly, which contradicts the long- established retention rule of Ag ion chromatography. Such behavior of Ag nanoparticles embedded in a silica column can be attributed to the differences in the molecular geometric configuration of cis/trans stilbenes. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Resolution of the stereoisomers of baclofen by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Weatherby, R.P.; Allan, R.D.; Johnston, G.A.R.

    1984-01-01

    The GABA analogue baclofen [3-(p-chlorophenyl)-4-aminobutanoic acid] has stereospecific actions on the peripheral and central nervous systems. This paper describes the resolution of tritium-labelled baclofen by high performance liquid chromatography on a reverse-phase C18 column using a chiral mobile phase. The method, which may have general application to certain other GABA analogues, affords optically pure (+)- and (-)-baclofen labelled with tritium to high specific activity suitable for ligand binding and other neurochemical studies. (Auth.)

  4. Chemical fingerprint of Ganmaoling granule by double-wavelength ultra high performance liquid chromatography and ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun

    2015-06-01

    A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Stationary and through-flow radiochemical detectors in cooperation with high performance liquid chromatography: Application in biochemistry

    International Nuclear Information System (INIS)

    Kehr, J.

    1986-01-01

    A review article is presented containing some original experimental data and discussing the usability of radiochemical detection of labelled compounds using high performance liquid chromatography. The stationary and through-flow types of detection are compared with respect to efficiency, chromatographic zone resolution, usability in biochemical research, and also to the current trends of development of liquid chromatography. (author). 3 figs., 1 tab., 19 refs

  6. Simultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography

    OpenAIRE

    Mohammad Faraji; Farzaneh Rahbarzare

    2016-01-01

    Background and objectives:  High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP) in foodstuff by high performance liquid chromatography. Materials and methods: Important factors in extraction, separation and determination process were optimiz...

  7. Fast, simple and efficient salting-out assisted liquid-liquid extraction of naringenin from fruit juice samples prior to their enantioselective determination by liquid chromatography.

    Science.gov (United States)

    Magiera, Sylwia; Kwietniowska, Ewelina

    2016-11-15

    In this study, an easy, simple and efficient method for the determination of naringenin enantiomers in fruit juices after salting-out-assisted liquid-liquid extraction (SALLE) and high-performance liquid chromatography (HPLC) with diode-array detection (DAD) was developed. The sample treatment is based on the use of water-miscible acetonitrile as the extractant and acetonitrile phase separation under high-salt conditions. After extraction, juice samples were incubated with hydrochloric acid in order to achieve hydrolysis of naringin to naringenin. The hydrolysis parameters were optimized by using a half-fraction factorial central composite design (CCD). After sample preparation, chromatographic separation was obtained on a Chiralcel® OJ-RH column using the mobile phase consisting of 10mM aqueous ammonium acetate:methanol:acetonitrile (50:30:20; v/v/v) with detection at 288nm. The average recovery of the analyzed compounds ranged from 85.6 to 97.1%. The proposed method was satisfactorily used for the determination of naringenin enantiomers in various fruit juices samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Medicinal cannabis: Principal cannabinoids concentration and their stability evaluated by a high performance liquid chromatography coupled to diode array and quadrupole time of flight mass spectrometry method.

    Science.gov (United States)

    Citti, Cinzia; Ciccarella, Giuseppe; Braghiroli, Daniela; Parenti, Carlo; Vandelli, Maria Angela; Cannazza, Giuseppe

    2016-09-05

    In the last few years, there has been a boost in the use of cannabis-based extracts for medicinal purposes, although their preparation procedure has not been standardized but rather decided by the individual pharmacists. The present work describes the development of a simple and rapid high performance liquid chromatography method with UV detection (HPLC-UV) for the qualitative and quantitative determination of the principal cannabinoids (CBD-A, CBD, CBN, THC and THC-A) that could be applied to all cannabis-based medicinal extracts (CMEs) and easily performed by a pharmacist. In order to evaluate the identity and purity of the analytes, a high-resolution mass spectrometry (HPLC-ESI-QTOF) analysis was also carried out. Full method validation has been performed in terms of specificity, selectivity, linearity, recovery, dilution integrity and thermal stability. Moreover, the influence of the solvent (ethyl alcohol and olive oil) was evaluated on cannabinoids degradation rate. An alternative extraction method has then been proposed in order to preserve cannabis monoterpene component in final CMEs. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Systematic chemical profiling of Citrus grandis 'Tomentosa' by ultra-fast liquid chromatography/diode-array detector/quadrupole time-of-flight tandem mass spectrometry.

    Science.gov (United States)

    Li, Pan-lin; Liu, Meng-hua; Hu, Jie-hui; Su, Wei-wei

    2014-03-01

    Citrus grandis 'Tomentosa', as the original plant of the traditional Chinese medicine "Huajuhong", has been used as antitussive and expectorant in clinic for thousands of years. The fruit epicarp and whole fruit of this plant were both literarily recorded and commonly used. In the present study, an ultra-fast liquid chromatography coupled with diode-array detection and quadrupole/time-of-flight mass spectrometry (UFLC-DAD-Q-TOF-MS/MS) based chemical profiling method was developed for rapid holistic quality evaluation of C. grandis 'Tomentosa', which laid basis for chemical comparison of two medicinal parts. As a result, forty-eight constituents, mainly belonging to flavonoids and coumarins, were unambiguously identified by comparison with reference standards and/or tentatively characterized by elucidating UV spectra, quasi-molecular ions and fragment ions referring to information available in literature. Both of the epicarp and whole fruit samples were rich in flavonoids and coumarins, but major flavonoids contents in whole fruit were significantly higher than in epicarp (P<0.5). The proposed method could be useful in quality control and standardization of C. grandis 'Tomentosa' raw materials and its products. Results obtained in this study will provide a basis for quality assessment and further study in vivo. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    OpenAIRE

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large am...

  11. Sugar Determination in Foods with a Radially Compressed High Performance Liquid Chromatography Column.

    Science.gov (United States)

    Ondrus, Martin G.; And Others

    1983-01-01

    Advocates use of Waters Associates Radial Compression Separation System for high performance liquid chromatography. Discusses instrumentation and reagents, outlining procedure for analyzing various foods and discussing typical student data. Points out potential problems due to impurities and pump seal life. Suggests use of ribose as internal…

  12. Experimental hydrophobicity parameters of perfluorinated alkylated substances from reversed-phase high performance liquid chromatography

    NARCIS (Netherlands)

    de Voogt, P.; Zurano, L.; Serné, P.; Haftka, J.J.H.

    2012-01-01

    Capacity factors of perfluorinated alkylated substances were obtained from isocratic reversed-phase high-performance liquid chromatography-mass spectrometry experiments at different organic modifier strengths of the mobile phase. The resulting capacity factor v. modifier strengths plots were

  13. Determination of phenolic acids and flavonoids in raw propolis by silica-supported ionic liquid-based matrix solid phase dispersion extraction high performance liquid chromatography-diode array detection.

    Science.gov (United States)

    Wang, Zhibing; Sun, Rui; Wang, Yuanpeng; Li, Na; Lei, Lei; Yang, Xiao; Yu, Aimin; Qiu, Fangping; Zhang, Hanqi

    2014-10-15

    The silica-supported ionic liquid (S-SIL) was prepared by impregnation and used as the dispersion adsorbent of matrix solid phase dispersion (MSPD) for the simultaneous extraction of eight phenolic acids and flavonoids, including caffeic acid, ferulic acid, morin, luteolin, quercetin, apigenin, chrysin, and kaempferide in raw propolis. High performance liquid chromatography with a Zorbax SB-C18 column (150mm×4.6mm, 3.5μm) was used for separation of the analytes. The mobile phase consisted of 0.2% phosphoric acid aqueous solution and acetonitrile and the flow rate of the mobile phase was 0.5mL/min. The experimental conditions for silica-supported ionic liquid-based matrix solid phase dispersion (S-SIL-based MSPD) were optimized. S-SIL containing 10% [C6MIM]Cl was used as dispersant, 20mL of n-hexane as washing solvent and 15mL of methanol as elution solvent. The ratio of S-SIL to sample was selected to be 4:1. The standard curves showed good linear relationship (r>0.9995). The limits of detection and quantification were in the range of 5.8-22.2ngmL(-1) and 19.2-74.0ngmL(-1), respectively. The relative standard deviations (RSDs) of intra-day and inter-day determination were lower than 8.80% and 11.19%, respectively. The recoveries were between 65.51% and 92.32% with RSDs lower than 8.95%. Compared with ultrasound-assisted extraction (UAE) and soxhlet extraction, the present method consumed less sample, organic solvent, and extraction time, although the extraction yields obtained by S-SIL-based MSPD are slightly lower than those obtained by UAE. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. High-performance liquid chromatography ultraviolet-photodiode array detection method for aflatoxin B1 in cattle feed supplements

    Science.gov (United States)

    Mochamad, Lazuardi; Hermanto, Bambang

    2017-01-01

    Aim: The objective of the current study is to determine the concentration of aflatoxin B1 using high-performance liquid chromatography (HPLC) with a photodiode array (PDA) detector. Materials and Methods: Aflatoxin B1 certified reference grade from Trilogy Analytical Laboratory dissolved acetonitrile (ACN) at 10 µg/mL was using standard assessment. HPLC instruments such as ultraviolet-PDA detector used a Shimadzu LC-6AD pump with DGU-20A5 degasser, communication module-20A, and PDA detector SPD-M20A with FRC-10A fraction collector. The HPLC was set isocratic method at 354 nm with a reverse-phase ODS C18 column (LiChrospher® 100 RP-18; diameter, 5 µm) under a 20°C controlled column chamber. Rheodyne® sample loops were performed in 20 µL capacities. The mobile phase was performed at fraction 63:26:11 H2O: methanol:ACN at pH 6.8. A total of 1 kg of feed contained 10% bread crumbs and 30% concentrated, 40% forage, and 20% soybean dregs were using commercials samples. Samples were extracted by ACN and separated with solid phase extraction ODS 1 mL than elution with mobile phase to collect at drying samples performed. The samples were ready to use after added 1 mL mobile phase than injected into the system of HPLC. Results: We found that the retention time of aflatoxin B1 was approximately 10.858 min. Linearity of 0.01-0.08 µg/mL aflatoxin B1 dissolved in mobile phase was obtained at R2=0.9. These results demonstrate that these methods can be used to analyze aflatoxin B1 and gain 89-99% recovery. The limit of detection of this assay was obtained at 3.5 × 10−6 µg/mL. Conclusion: This method was easy to apply and suitable to analyzing at small concentrations of aflatoxin B1 in formulated product of feed cattle. PMID:28919686

  15. Fast and parallel determination of PCB 77 and PCB 180 in plasma using ultra performance liquid chromatography with diode array detection: A pharmacokinetic study in Swiss albino mouse.

    Science.gov (United States)

    Ramanujam, N; Sivaselvakumar, M; Ramalingam, S

    2017-11-01

    A simple, sensitive and reproducible ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of polychlorinated biphenyl (PCB) 77 and PCB 180 in mouse plasma. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP 18 column maintained at 35°C. Quantification was performed on a photodiode array detector set at 215 nm and PCB 101 was used as internal standard (IS). PCB 77, PCB 180, and IS retention times were 2.6, 4.7 and 2.8 min, respectively, and the total run time was 6 min. The method was validated for specificity, selectivity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 10-3000 ng/mL for PCB 77 and PCB 180. Intra- and inter-day precisions for PCBs 77 and 180 were found to be good with CV <4.64%, and the accuracy ranged from 98.90 to 102.33% in mouse plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of PCBs 77 and 180 in mouse plasma. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Quantification of patulin in fruit leathers by ultra-high-performance liquid chromatography-photodiode array (UPLC-PDA).

    Science.gov (United States)

    Maragos, Chris M; Busman, Mark; Ma, Liang; Bobell, John

    2015-01-01

    Patulin is a mycotoxin commonly found in certain fruit and fruit products. For this reason many countries have established regulatory limits pertaining to, in particular, apple juice and apple products. Fruit leathers are produced by dehydrating fruit puree, leaving a sweet product that has a leathery texture. A recent report in the literature described the detection of patulin at substantial levels in fruit leathers. To investigate this further, an ultra-high-performance liquid chromatography-photodiode array (UPLC-PDA) method was developed for the sensitive detection of patulin in fruit leathers. Investigations were also made of the suitability of direct analysis in real time-mass spectrometry (DART-MS) for detection of patulin from the surface of fruit leathers. Results indicated DART-MS was insufficiently sensitive for quantification from the surface of home-style apple leathers, although patulin spiked onto the surface of leather or peel could be detected. The UPLC-PDA method was used to determine the fate of patulin during the preparation of home-made fruit leathers. Interestingly, when a home-style process was used, the patulin was not destroyed, but rather increased in concentration as the puree was dehydrated. The UPLC-PDA method was also used to screen for patulin in commercial fruit leathers. Of the 36 products tested, 14 were above the limit of detection (3.5 μg kg(-1)) and nine were above the limit of quantification (12 μg kg(-1)). Positive samples were confirmed by UPLC-MS/MS. Only one sample was found above the US regulatory limit for single-strength apple juice products (50 μg kg(-1)). These results suggest patulin can be concentrated during preparation and can be found in fruit leathers. The limited survey suggests that patulin is fairly prevalent in such commercial products, but that the levels are usually low.

  17. Analysis of the Constituents in “Zhu She Yong Xue Shuan Tong” by Ultra High Performance Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry Combined with Preparative High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Lin-Lin Wang

    2015-11-01

    Full Text Available “Zhu She Yong Xue Shuan Tong” lyophilized powder (ZSYXST, consists of a series of saponins extracted from Panax notoginseng, which has been widely used in China for the treatment of strokes. In this study, an ultra-high performance liquid chromatography with quadrupole time-of-flight mass spectrometry (UHPLC-Q-TOF/MS combined with preparative high performance liquid chromatography (PHPLC method was developed to rapidly identify both major and minor saponins in ZSYXST. Some high content components were removed through PHPLC in order to increase the sensitivity of the trace saponins. Then, specific characteristic fragment ions in both positive and negative mode were utilized to determine the types of aglycone, saccharide, as well as the saccharide chain linkages. As a result, 94 saponins, including 20 pairs of isomers and ten new compounds, which could represent higher than 98% components in ZSYXST, were identified or tentatively identified in commercial ZSYXST samples.

  18. Enantiomeric high-performance liquid chromatography resolution and absolute configuration of 6β-benzoyloxy-3α-tropanol.

    Science.gov (United States)

    Muñoz, Marcelo A; González, Natalia; Joseph-Nathan, Pedro

    2016-07-01

    The absolute configuration of the naturally occurring isomers of 6β-benzoyloxy-3α-tropanol (1) has been established by the combined use of chiral high-performance liquid chromatography with electronic circular dichroism detection and optical rotation detection. For this purpose (±)-1, prepared in two steps from racemic 6-hydroxytropinone (4), was subjected to chiral high-performance liquid chromatography with electronic circular dichroism and optical rotation detection allowing the online measurement of both chiroptical properties for each enantiomer, which in turn were compared with the corresponding values obtained from density functional theory calculations. In an independent approach, preparative high-performance liquid chromatography separation using an automatic fraction collector, yielded an enantiopure sample of OR (+)-1 whose vibrational circular dichroism spectrum allowed its absolute configuration assignment when the bands in the 1100-950 cm(-1) region were compared with those of the enantiomers of esters derived from 3α,6β-tropanediol. In addition, an enantiomerically enriched sample of 4, instead of OR (±)-4, was used for the same transformation sequence, whose high-performance liquid chromatography follow-up allowed their spectroscopic correlation. All evidences lead to the OR (+)-(1S,3R,5S,6R) and OR (-)-(1R,3S,5R,6S) absolute configurations, from where it follows that samples of 1 isolated from Knightia strobilina and Erythroxylum zambesiacum have the OR (+)-(1S,3R,5S,6R) absolute configuration, while the sample obtained from E. rotundifolium has the OR (-)-(1R,3S,5R,6S) absolute configuration. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Simple and sensitive monitoring of sulfonamide veterinary residues in milk by stir bar sorptive extraction based on monolithic material and high performance liquid chromatography analysis.

    Science.gov (United States)

    Huang, Xiaojia; Qiu, Ningning; Yuan, Dongxing

    2009-11-13

    A simple, rapid, and sensitive method for the quantitative monitoring of five sulfonamide antibacterial residues (SAs) in milk was developed by stir bar sorptive extraction (SBSE) coupling to high performance liquid chromatography with diode array detection. The analytes were concentrated by SBSE based on poly (vinylimidazole-divinylbenzene) monolithic material as coating. The extraction procedure was very simple, milk was diluted with water then directly sorptive extraction without elimination of fats and protein in samples was required. To achieve optimum extraction performance for SAs, several parameters, including extraction and desorption time, desorption solvent, ionic strength and pH value of sample matrix were investigated. Under the optimized experimental conditions, low detection limits (S/N=3) quantification limits (S/N=10) of the proposed method for the target compounds were achieved within the range of 1.30-7.90 ng/mL and 4.29-26.3 ng/mL from spiked milk, respectively. Good linearities were obtained for SAs with the correlation coefficients (R(2)) above 0.996. Finally, the proposed method was successfully applied to the determination of SAs compounds in different milk samples and satisfied recoveries of spiked target compounds in real samples were obtained.

  20. Quantitative analysis of phylloquinone (vitamin K1) in soy bean oils by high-performance liquid chromatography.

    Science.gov (United States)

    Zonta, F; Stancher, B

    1985-07-19

    A high-performance liquid chromatographic method for determining phylloquinone (vitamin K1) in soy bean oils is described. Resolution of vitamin K1 from interfering peaks of the matrix was obtained after enzymatic digestion, extraction and liquid-solid chromatography on alumina. An isocratic reversed-phase chromatography with UV detection was used in the final stage. The quantitation was carried out by the standard addition method, and the recovery of the whole procedure was 88.2%.

  1. Comparison of extraction methods for the analysis of natural dyes in historical textiles by high-performance liquid chromatography.

    Science.gov (United States)

    Valianou, Lemonia; Karapanagiotis, Ioannis; Chryssoulakis, Yannis

    2009-12-01

    Different methods for the extraction of Dactylopius coccus Costa, Rubia tinctorum L., Isatis tinctoria L., Reseda luteola L., Curcuma longa L. and Cotinus coggygria Scop. from wool fibres are investigated using high-performance liquid chromatography with diode array detector (HPLC-DAD). The efficiencies of five extraction methods which include the use of HCl (widely used extraction method), citric acid, oxalic acid, TFA and a combination of HCOOH and EDTA are compared on the basis of the (a) number, (b) relative quantities, measured as HPLC peak areas and (c) signal-to-noise ratios (S/N) of the compounds extracted from the wool substrates. Flavonoid glycosides and curcuminoids contained in R. luteola L. and C. longa L., respectively, according to liquid chromatography with mass spectrometry (LC-MS) identifications, are not detected after treating the fibres with HCl. All the other milder methods are successful in extracting these compounds. Experiments are performed using HPLC-DAD to compare the HPLC peak areas and the S/N of the following extracted compounds: indigotin, indirubin, curcumin, demethoxycurcumin, bisdemethoxycurcumin, fisetin, sulfuretin, luteolin, luteolin-7-O-glucoside, apigenin, carminic acid, alizarin, puruprin and rubiadin. It is shown that the TFA method provides overall the best results as it gives elevated extraction yields except for fisetin, luteolin, apigenin and luteolin-7-O-glucoside and highest S/N except for fisetin and luteolin-7-O-glucoside. It is noteworthy that treatment of the fibres with the typical HCl extraction method results overall in very low S/N. The TFA method is selected for further studies, as follows. First, it is applied on silk dyed samples and compared with the HCl method. The same relative differences of the TFA and HCl methods observed for the wool dyed samples are reported for the silk dyed samples too, except for rubiadin, luteolin and apigenin. Thus, in most cases, the nature of the substrate (wool or silk

  2. Preparation and Characterization of a Polymeric Monolithic Column for Use in High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Bindis, Michael P.; Bretz, Stacey Lowery; Danielson, Neil D.

    2011-01-01

    The high-performance liquid chromatography (HPLC) experiment, most often done in the undergraduate analytical instrumentation laboratory course, generally illustrates reversed-phase chromatography using a commercial C[subscript]18 silica column. To avoid the expense of periodic column replacement and introduce a choice of columns with different…

  3. High-performance liquid chromatography of rat and mouse islet polypeptides

    DEFF Research Database (Denmark)

    Linde, S; Hansen, B; Welinder, B S

    1990-01-01

    After preparative high-performance liquid chromatography of mouse islet culture medium, concentrated on disposable C18 cartridges (Sep-Pak), an unexpected insulin immunoreactive peak eluting earlier than mouse insulin I and II was detected. Molecular mass determination by mass spectrometry...... on the buffer, the organic modifier and the procedure. In particular the use of methanol-trifluoroacetic acid resulted in extensive oxidation. The oxidation could be minimized by adding 2 mM dithiothreitol to the buffer and by degassing and/or nitrogen-bubbling of the buffer. Minimal formation of Met...

  4. Characterization of Extracellular Vesicles by Size-Exclusion High-Performance Liquid Chromatography (HPLC).

    Science.gov (United States)

    Huang, Tao; He, Jiang

    2017-01-01

    Extracellular vesicles (EVs) have recently attracted substantial attention due to the potential diagnostic and therapeutic relevance. Although a variety of techniques have been used to isolate and analyze EVs, it is still far away from satisfaction. Size-exclusion chromatography (SEC), which separates subjects by size, has been widely applied in protein purification and analysis. The purpose of this chapter is to show the applications of size-exclusion high-performance liquid chromatography (HPLC) as methods for EV characterization of impurities or contaminants of small size, and thus for quality assay for the purity of the samples of EVs.

  5. Determination of phthalate esters from environmental water samples by micro-solid-phase extraction using TiO2 nanotube arrays before high-performance liquid chromatography.

    Science.gov (United States)

    Zhou, Qingxiang; Fang, Zhi; Liao, Xiangkun

    2015-07-01

    We describe a highly sensitive micro-solid-phase extraction method for the pre-concentration of six phthalate esters utilizing a TiO2 nanotube array coupled to high-performance liquid chromatography with a variable-wavelength ultraviolet visible detector. The selected phthalate esters included dimethyl phthalate, diethyl phthalate, dibutyl phthalate, butyl benzyl phthalate, bis(2-ethylhexyl)phthalate and dioctyl phthalate. The factors that would affect the enrichment, such as desorption solvent, sample pH, salting-out effect, extraction time and desorption time, were optimized. Under the optimum conditions, the linear range of the proposed method was 0.3-200 μg/L. The limits of detection were 0.04-0.2 μg/L (S/N = 3). The proposed method was successfully applied to the determination of six phthalate esters in water samples and satisfied spiked recoveries were achieved. These results indicated that the proposed method was appropriate for the determination of trace phthalate esters in environmental water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Liquid chromatography-mass spectrometry identification of anthocyanins of isla oca (Oxalis tuberosa, Mol.) tubers.

    Science.gov (United States)

    Alcalde-Eon, Cristina; Saavedra, Gloria; de Pascual-Teresa, Sonia; Rivas-Gonzalo, Julián C

    2004-10-29

    High-performance liquid chromatography (HPLC)-diode array detection (DAD)-mass spectrometry (MS) techniques have been successfully employed in the identification of the anthocyanins of the coloured tubers of isla oca (Oxalis tuberosa), the second most cultivated tuber in the Andean region. Tubers underwent a pre-treatment step in order to inhibit enzymatic reactions and to obtain a stable powder or "concentrate". This concentrate was dissolved, purified and then analysed. Eight different compounds were found. The major peaks were malvidin glucosides (malvidin 3-O-glucoside and 3,5-O-diglucoside). The rest of the peaks were 3,5-O-diglucosides of petunidin and peonidin, and 3-O-glucosides of delphinidin, petunidin and peonidin. Only malvidin 3-O-acetylglucoside-5-O-glucoside was found as an acylated anthocyanin.

  7. Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

    Directory of Open Access Journals (Sweden)

    Vani Chandrashekar

    2016-01-01

    Full Text Available Hb A1c measurement is subject to interference by hemoglobin traits and this is dependent on the method used for determination. In this paper we studied the difference between Hb A1c measured by HPLC in hemoglobin traits and normal chromatograms. We also studied the correlation of Hb A1c with age. Hemoglobin analysis was carried out by high performance liquid chromatography. Spearman’s rank correlation was used to study correlation between A1c levels and age. Mann-Whitney U test was used to study the difference in Hb A1c between patients with normal hemoglobin and hemoglobin traits. A total of 431 patients were studied. There was positive correlation with age in patients with normal chromatograms only. No correlation was seen in Hb E trait or beta thalassemia trait. No significant difference in Hb A1c of patients with normal chromatograms and patients with hemoglobin traits was seen. There is no interference by abnormal hemoglobin in the detection of A1c by high performance liquid chromatography. This method cannot be used for detection of A1c in compound heterozygous and homozygous disorders.

  8. Fabric phase sorptive extraction-high performance liquid chromatography-photo diode array detection method for simultaneous monitoring of three inflammatory bowel disease treatment drugs in whole blood, plasma and urine.

    Science.gov (United States)

    Kabir, Abuzar; Furton, Kenneth G; Tinari, Nicola; Grossi, Laurino; Innosa, Denise; Macerola, Daniela; Tartaglia, Angela; Di Donato, Valentina; D'Ovidio, Cristian; Locatelli, Marcello

    2018-05-01

    This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of three drug residues (ciprofloxacin, sulfasalazine, and cortisone) in human whole blood, plasma, and urine samples, generally administered in human patients to treat inflammatory bowel disease (IBD). The drugs of interest were well resolved using a Luna C 18 column (250 mm × 4.6 mm; 5 μm particle size) in gradient elution mode within 20 min. The analytical method was optimized and validated in the range 0.05-10 μg/mL for whole blood, 0.25-10 μg/mL for human plasma, and 0.10-10 μg/mL for human urine. Blank human whole blood, plasma, and urine were used as the sample matrix for the method development and validation; while methyl-p-hydroxybenzoate was used as the internal standard (IS). Weighted-matrix matched standard calibration curves showed a good linearity up to a concentration of 10 μg/mL. The intra- and inter-day accuracy values (precision and trueness) were found in the range from -10.9% to 12.3%, and the performances of the validated FPSE-HPLC-PDA were further tested on real IBD patient samples. This is the first FPSE procedure applied simultaneously to whole blood, plasma, and urine samples for the determination of residual IBD drugs, which possess a wide range of polarity (logP values ranging from 2.30 for Ciprofloxacin, to 1.66 for Cortisone, and 2.92 for Sulfasalazine). The new approach exhibits high potential for immediate adoptation as a rapid, robust and green analytical tool for future clinical and pharmaceutical applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Validation and global uncertainty of a liquid chromatographic with diode array detection method for the screening of azoxystrobin, kresoxim-methyl, trifloxystrobin, famoxadone, pyraclostrobin and fenamidone in grapes and wine.

    Science.gov (United States)

    de Melo Abreu, Susana; Caboni, Pierluigi; Cabras, Paolo; Garau, Vincenzo Luigi; Alves, Arminda

    2006-07-28

    Azoxystrobin, kresoxim-methyl, trifloxystrobin, pyraclostrobin, famoxadone and fenamidone are permitted Q(o) Inhibitor (Q(o)I) fungicides applied to vine in some European countries for the treatment of downy and powdery mildews. In this work, a method is validated for the analysis of these fungicides in grapes and wine. This screening method consists in a simple one step liquid-liquid extraction followed by liquid chromatography (LC) fitted with a diode array detector (DAD). Limits of detection for grapes and wine were below 0.2 mg kg(-1) or mg l(-1), precision was not above 13%, and recoveries were, on average, 95+/-5% for grapes and 104+/-6% for wine. Global uncertainties evaluated in the concentration range from 0.25 to 2.50 mg l(-1) were below 20%. A confirmatory method by gas chromatography (GC) with mass spectrometry (MS) detection was used.

  10. Characterisation of nucleosides and nucleobases in Mactra veneriformis by high performance liquid chromatography coupled with diode array detector-mass spectrometry (HPLC-DAD-MS).

    Science.gov (United States)

    Liu, Rui; Ji, Jing; Wang, Lingchong; Chen, Shiyong; Guo, Sheng; Wu, Hao

    2012-11-15

    Mactra veneriformis has been used as sea food and traditional Chinese medicine (TCM) for thousands of years in China. In the present study, a high performance liquid chromatograph coupled with photodiode array detector and electrospray ionisation-mass spectrometer (HPLC-DAD-ESI-MS) method was established for detection of the nucleosides and nucleobases in M. veneriformis from four aquaticultural area of Jiangsu during different harvest time of one year. The validated method was successfully applied to identifying 10 nucleosides and nucleobases in 48 M. veneriformis samples. Quantitative analysis showed that nucleosides and nucleobases are rich in all M. veneriformis samples. However, their contents vary in different areas and harvest times. Principal component analysis (PCA) was used to classify the 48 samples based on the contents of the nucleosides and nucleobases. As a result, the samples could be mainly clustered into four groups, which was similar as aquaticultural areas classification. Based on the results, present method might be applicable for the quality control of M. veneriformis, or even other marine shellfish aquiculture and their products, and the quality of M. veneriformis might be more related with aquaticultural areas. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids

    DEFF Research Database (Denmark)

    Lue, Bena-Marie; Guo, Zheng; Xu, X.B.

    2008-01-01

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found...... essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method...

  12. Crosstalk of HgCdTe LWIR n-on-p diode arrays

    International Nuclear Information System (INIS)

    Sun Yinghui; Zhang Bo; Yu Meifang; Liao Qingjun; Zhang Yan; Wen Xin; Jiang Peilu; Hu Xiaoning; Dai Ning

    2009-01-01

    Crosstalk of HgCdTe long-wavelength infrared (LWIR) n-on-p diode arrays was measured using scanning laser microscopy. During the measurement, HgCdTe diode arrays with different diode pitches were frontside illuminated by a He-Ne laser at liquid nitrogen temperature and room temperature. The experimental results show that crosstalk between the nearest neighboring diodes decreases exponentially as the diode pitch increases, and the factors that affect the obtained crosstalk are presented and analyzed. Crosstalk out of the nominal diode area (optically sensitive area) is also measured and discussed.

  13. A fabric phase sorptive extraction-High performance liquid chromatography-Photo diode array detection method for the determination of twelve azole antimicrobial drug residues in human plasma and urine.

    Science.gov (United States)

    Locatelli, Marcello; Kabir, Abuzar; Innosa, Denise; Lopatriello, Teresa; Furton, Kenneth G

    2017-01-01

    This paper reports a novel fabric phase sorptive extraction-high performance liquid chromatography-photodiode array detection (FPSE-HPLC-PDA) method for the simultaneous extraction and analysis of twelve azole antimicrobial drug residues that include ketoconazole, terconazole, voriconazole, bifonazole, clotrimazole, tioconazole, econazole, butoconazole, miconazole, posaconazole, ravuconazole, and itraconazole in human plasma and urine samples. The selected azole antimicrobial drugs were well resolved by using a Luna C 18 column (250mm×4.6mm; 5μm particle size) in gradient elution mode within 36min. The analytical method was calibrated and validated in the range from 0.1 to 8μg/mL for all the drug compounds. Blank human plasma and urine were used as the sample matrix for the analysis; while benzyl-4-hydroxybenzoate was used as the internal standard (IS). The limit of quantification of the FPSE-HPLC-PDA method was found as 0.1μg/mL and the weighted-matrix matched standard calibration curves of the drugs showed a good linearity upto a concentration of 8μg/mL. The parallelism tests were also performed to evaluate whether overrange sample can be analyzed after dilution, without compromising the analytical performances of the validated method. The intra- and inter-day precision (RSD%) values were found ≤13.1% and ≤13.9%, respectively. The intra- and inter-day trueness (bias%) values were found in the range from -12.1% to 10.5%. The performances of the validated FPSE-HPLC-PDA were further tested on real samples collected from healthy volunteers after a single dose administration of itraconazole and miconazole. To the best of our knowledge, this is the first FPSE extraction procedure applied on plasma and urine samples for the simultaneous determination of twelve azole drugs possessing a wide range of logK ow values (extending from 0.4 for fluconazole to 6.70 of butoconazole) and could be adopted as a rapid and robust green analytical tool for clinical and

  14. tRNA separation by high-performance liquid chromatography using an aggregate of ODS-Hypersil and trioctylmethylammonium chloride

    NARCIS (Netherlands)

    Bischoff, Rainer; Graeser, E.; Mclaughlin, L.W.

    1983-01-01

    High-performance liquid chromatography on a reversed-phase support treated with a tetraalkylammonium salt was used to separate tRNAs from baker's yeast. While resolution by this column appears to result from both anion-exchange and reversed-phase chromatography, it is the hydrophobic interactions

  15. An on-line high performance liquid chromatography-crocin bleaching assay for detection of antioxidants

    NARCIS (Netherlands)

    Bountagkidou, O.; Klift, van der E.J.C.; Tsimidou, M.Z.; Ordoudi, S.A.; Beek, van T.A.

    2012-01-01

    An on-line HPLC (high performance liquid chromatography) method for the rapid screening of individual antioxidants in mixtures was developed using crocin as a substrate (i.e. oxidation probe) and 2,2'-azobis(2-amidinopropane dihydrochloride (AAPH)) in phosphate buffer (pH 7.5) as a radical

  16. Multiresidue screening method for detection of benzimidazoles and their metabolites in liver and muscle by high-performance liquid chromatography: method development and validation according to Commission Decision 2002/657/EC

    Directory of Open Access Journals (Sweden)

    Marilena Gili

    2014-02-01

    Full Text Available The use of veterinary drugs may cause the presence of residues in food of animal origin if appropriate withdrawal periods are not respected. A high-performance liquid chromatography (HPLC method has been developed for the simultaneous detection of 11 benzimidazole residues, including metabolites – albendazole, albendazole sulphoxide, albendazole sulphone, fenbendazole, fenbendazole sulphoxide (oxfendazole, fenbendazole sulphone, flubendazole, mebendazole, oxibendazole, thiabendazole, 5-hydroxythiabendazole – in bovine, ovine, equine, swine, rabbit and poultry liver and in bovine, swine and fish muscle. After extraction with a dicloromethane/acetonitrile solution (35/65 v/v containing 5% ammonium hydroxide, the solvent was evaporated to dryness, the residue was dissolved in HCl 0.1 M, defatted with hexane, purified on a strong cation exchange solid-phase extraction cartridge and analysed in HPLC with diode array and fluorescence detectors. The method was validated as screening qualitative method evaluating, according to Commission Decision 2002/657/EC criteria, specificity, CCb and b error at cut off level of 25 mg/kg and ruggedness.

  17. Versatile ligands for high-performance liquid chromatography: An overview of ionic liquid-functionalized stationary phases.

    Science.gov (United States)

    Zhang, Mingliang; Mallik, Abul K; Takafuji, Makoto; Ihara, Hirotaka; Qiu, Hongdeng

    2015-08-05

    Ionic liquids (ILs), a class of unique substances composed purely by cation and anions, are renowned for their fascinating physical and chemical properties, such as negligible volatility, high dissolution power, high thermal stability, tunable structure and miscibility. They are enjoying ever-growing applications in a great diversity of disciplines. IL-modified silica, transforming the merits of ILs into chromatographic advantages, has endowed the development of high-performance liquid chromatography (HPLC) stationary phase with considerable vitality. In the last decade, IL-functionalized silica stationary phases have evolved into a series of branches to accommodate to different HPLC modes. An up-to-date overview of IL-immobilized stationary phases is presented in this review, and divided into five parts according to application mode, i.e., ion-exchange, normal-phase, reversed-phase, hydrophilic interaction and chiral recognition. Specific attention is channeled to synthetic strategies, chromatographic behavior and separation performance of IL-functionalized silica stationary phases. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Recent advances in ultra-high performance liquid chromatography for the analysis of traditional chinese medicine

    Science.gov (United States)

    Traditional Chinese medicines (TCMs) have been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra Performance Liquid Chromatography (UHPLC) is a relatively new technique offering new possibilities in liquid chromatography. This paper reviews recen...

  19. Determination of flavonoids in plant material by HPLC with diode-array and electro-array detections.

    Science.gov (United States)

    Mattila, P; Astola, J; Kumpulainen, J

    2000-12-01

    A high-performance liquid chromatographic (HPLC) method with in-line connected diode-array (DAD) and electro-array (EC) detection to identify and quantify 17 flavonoids in plant-derived foods is described. Catechins were extracted from the samples using ethyl acetate, and quantification of these compounds was performed with the EC detector. Other flavonoids were quantified with DAD after acid hydrolysis. The methods developed were effective for the determination of catechins and other flavonoids in plant-derived foods. Responses of the detection systems were linear within the range evaluated, 20-200 ng/injection (DAD) and 20-100 ng/injection (EC), with correlation coefficients exceeding 0.999. Coefficient of variation was under 10.5%, and recoveries of flavonoids ranged from 70 to 124%. Purity of the flavonoid peaks was confirmed by combining the spectral and voltammetric data.

  20. Improved method for the determination of the cortisol production rate using high-performance liquid chromatography and liquid scintillation counting

    NARCIS (Netherlands)

    van Ingen, H. E.; Endert, E.

    1988-01-01

    Two new methods for the determination of the cortisol production rate using reversed-phase high-performance liquid chromatography are described. One uses ultraviolet detection at 205 nm, the other on-line post-column derivatization with benzamidine, followed by fluorimetric detection. The specific

  1. Analysis of lignans in Magnoliae Flos by turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Xuan; Chen, Cen; Ye, Xiaolan; Song, Fenyun; Fan, Guorong; Wu, Fuhai

    2016-04-01

    In this study, a method coupling turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry was developed for analyzing the lignans in Magnoliae Flos. By the online pretreatment of turbulent flow chromatography solid-phase extraction, the impurities removal and analytes concentration were automatically processed, and the lignans were separated rapidly and well. Seven lignans of Magnoliae Flos including epieudesmin, magnolin, 1-irioresinol-B-dimethyl ether, epi-magnolin, fargesin aschantin, and demethoxyaschantin were identified by comparing their retention behavior, UV spectra, and mass spectra with those of reference substances or literature data. The developed method was validated, and the good results showed that the method was not only automatic and rapid, but also accurate and reliable. The turbulent flow chromatography with online solid-phase extraction and high-performance liquid chromatography with tandem mass spectrometry method holds a high potential to become an effective method for the quality control of lignans in Magnoliae Flos and a useful tool for the analysis of other complex mixtures. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Analysis of new psychoactive substances in human urine by ultra-high performance supercritical fluid and liquid chromatography: Validation and comparison.

    Science.gov (United States)

    Borovcová, Lucie; Pauk, Volodymyr; Lemr, Karel

    2018-05-01

    New psychoactive substances represent serious social and health problem as tens of new compounds are detected in Europe annually. They often show structural proximity or even isomerism, which complicates their analysis. Two methods based on ultra high performance supercritical fluid chromatography and ultra high performance liquid chromatography with mass spectrometric detection were validated and compared. A simple dilute-filter-and-shoot protocol utilizing propan-2-ol or methanol for supercritical fluid or liquid chromatography, respectively, was proposed to detect and quantify 15 cathinones and phenethylamines in human urine. Both methods offered fast separation (chromatography. Limits of detection in urine ranged from 0.01 to 2.3 ng/mL, except for cathinone (5 ng/mL) in supercritical fluid chromatography. Nevertheless, this technique distinguished all analytes including four pairs of isomers, while liquid chromatography was unable to resolve fluoromethcathinone regioisomers. Concerning matrix effects and recoveries, supercritical fluid chromatography produced more uniform results for different compounds and at different concentration levels. This work demonstrates the performance and reliability of supercritical fluid chromatography and corroborates its applicability as an alternative tool for analysis of new psychoactive substances in biological matrixes. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Serum Protein Profile Study of Clinical Samples Using High Performance Liquid Chromatography-Laser Induced Fluorescence

    DEFF Research Database (Denmark)

    Karemore, Gopal Raghunath; Ukendt, Sujatha; Rai, Lavanya

    2009-01-01

    The serum protein profiles of normal subjects, patients diagnosed with cervical cancer, and oral cancer were recorded using High Performance Liquid Chromatography combined with Laser Induced Fluorescence detection (HPLC-LIF). Serum protein profiles of the above three classes were tested for estab...

  4. DETERMINATION OF CHLOROPHEONIS, NITROPHENOIS AND METHYLPHENOIS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Science.gov (United States)

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  5. DETERMINATION OF CHLOROPHENOLS, NITROPHENOLS, AND METHYLPHENOLS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Science.gov (United States)

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  6. High-performance liquid chromatography determination of dapsone, monoacetyldapsone, and pyrimethamine in filter paper blood spots

    DEFF Research Database (Denmark)

    Rønn, A M; Lemnge, M M; Angelo, H R

    1995-01-01

    A high-performance liquid chromatography method for the simultaneous analysis of dapsone (DDS), the major metabolite of DDS, monoacetyldapsone (MADDS), and pyrimethamine (PYR) was modified for capillary blood samples obtained by finger prick and dried on filter paper. Limit of quantitation using...

  7. Nitrate and nitrite content in bottled beverages by ion-pair high-performance liquid chromatography.

    Science.gov (United States)

    Song, Yang; Deng, Gui-Fang; Xu, Xiang-Rong; Chen, Yong-Hong; Chen, Feng; Li, Hua-Bin

    2013-01-01

    Nitrate and nitrite levels in six types of beverages--total of 292 individual samples from 73 brands (four bottles each)--from Guangzhou city in China were evaluated by ion-pair high-performance liquid chromatography. All samples contained nitrate. Nitrate and nitrite ranges were 0.43-46.08 and safety of Chinese bottled beverages.

  8. Improving Reliability of High Power Quasi-CW Laser Diode Arrays Operating in Long Pulse Mode

    Science.gov (United States)

    Amzajerdian, Farzin; Meadows, Byron L.; Barnes, Bruce W.; Lockard, George E.; Singh, Upendra N.; Kavaya, Michael J.; Baker, Nathaniel R.

    2006-01-01

    Operating high power laser diode arrays in long pulse regime of about 1 msec, which is required for pumping 2-micron thulium and holmium-based lasers, greatly limits their useful lifetime. This paper describes performance of laser diode arrays operating in long pulse mode and presents experimental data of the active region temperature and pulse-to-pulse thermal cycling that are the primary cause of their premature failure and rapid degradation. This paper will then offer a viable approach for determining the optimum design and operational parameters leading to the maximum attainable lifetime.

  9. Identification of Polish cochineal (Porphyrophora polonica L.) in historical textiles by high-performance liquid chromatography coupled with spectrophotometric and tandem mass spectrometric detection.

    Science.gov (United States)

    Lech, Katarzyna; Jarosz, Maciej

    2016-05-01

    The present work reports a method for identification of Polish cochineal (Porphyrophora polonica L.) in historical fabrics by the use of high-performance liquid chromatography coupled with diode array and tandem mass spectrometric detection with electrospray ionization (HPLC-DAD-ESI MS/MS). This hyphened technique allows detection and identification of 16 new minor colorants present in the discussed scale insect (including two previously observed by Wouters and Verhecken (Ann Soc Entomol Fr. 1989;25:393-410), but specified only as compounds of unknown structures) that do not occur (e.g., in American cochineal). The MS/MS experiments, complemented with UV-VIS data, enable identification of mono- and di-, C- and O-hexosides of kermesic and flavokermesic acids or their derivatives. The present paper introduces a fingerprint of color compounds present in Polish cochineal and defines them, particularly pp6 (ppI, O-hexoside of flavokermesic acid), as its markers allow distinguishing of Polish-cochineal reds from the American ones. Usefulness of the selected set of markers for identification of Polish cochineal has been demonstrated in the examination of textiles from the collection of the National Museum in Warsaw using the multiple reaction monitoring (MRM) method, originally elaborated on the basis of this study.

  10. Enantioselective analysis of drugs: contributions of high-performance liquid chromatography and capillary electrophoresis

    OpenAIRE

    Bonato, Pierina Sueli; Jabor, Valquíria Aparecida Polisel; Gaitani, Cristiane Masetto de

    2005-01-01

    The demand for analytical methods suitable for accurate and reproducible determination of drug enantiomers has increased significantly in the last years. High-performance liquid chromatography (HPLC) using chiral stationary phases and capillary electrophoresis (CE) are the most important techniques used for this purpose. In this paper, the fundamental aspects of chiral separations using both techniques are presented. Some important aspects for the development of enantioselective methods, part...

  11. Analysis of drugs of abuse in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Fernández, P; Regenjo, M; Bermejo, A M; Fernández, A M; Lorenzo, R A; Carro, A M

    2015-04-01

    Opioids and cocaine are widely used at present, both for recreational purposes and as drugs of abuse. This raises the need to develop new analytical methods specifically designed for the simultaneous detection of several drugs of abuse in biological samples. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a new sample treatment for the simultaneous extraction of morphine (MOR), 6-acetylmorphine (6AM), cocaine (COC), benzoylecgonine (BZE) and methadone (MET) from human plasma. Preliminary assays were done before developing an experimental design based on a Uniform Network Doehlert which allowed the optimum extraction conditions to be identified, namely: a volume of extractant solvent (chloroform) and dispersant solvent (acetonitrile) of 220 µl and 3.2 ml, respectively; 0.2 g of NaCl as a salting-out additive; pH 10.6 and ultrasound stirring for 3.5 min. The resulting extracts were analyzed by high-performance liquid chromatography with photodiode array detection (HPLC-PDA), using an XBridge® RP18 column (250 × 4.6 mm i.d., 5 µm particle size). Calibration graphs were linear over the concentration range 0.1-10 µg ml⁻¹, and detection limits ranged from 13.9 to 28.5 ng ml⁻¹. Precision calculated at three different concentration levels in plasma was included in the range 0.1-6.8% RSD. Recoveries of the five drugs were all higher than 84% on average. Finally the proposed method was successfully applied to 22 plasma samples from heroin, cocaine and/or methadone users, and the most frequently detected drug was benzoylecgonine, followed by methadone, cocaine and morphine. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Theoretical aspects of gradient reversed-phase high performance liquid chromatography of styrene-butylacrylate block copolymers

    NARCIS (Netherlands)

    Kolarova, L.; Jandera, P.; Vonk, E.C.; Claessens, H.A.

    2004-01-01

    Butylacrylate – styrene co-polymers prepared by atom transfer radical polymeratization were separated on an octadecyl silica column by gradient elution with tetrahydrofuran in water, up to the molar masses 10,000. In reversed-phase high performance liquid chromatography (RP-HPLC), the retention of

  13. Radiation effects in semiconductor laser diode arrays

    International Nuclear Information System (INIS)

    Carson, R.F.

    1988-01-01

    The effects of radiation events are important for many of the present and future applications that involve optoelectronic components. Laser diodes show a strong resistance to degradation by gamma rays, prompt x-rays and (to a lesser extent), neutrons. This is due to the short carrier lifetime that is associated with stimulated emission and the high current injection conditions that are present in these devices. Radiation-resistant properties should carry over to many of the more recently developed devices such as multi-stripe array and broad area laser diodes. There are, however, additional considerations for radiation tolerance that are introduced by these devices. Arrays and other high power laser diodes have larger active region volumes than lower power single stripe devices. In addition, evanescent field coupling between stripes, the material quality available from newer MOCVD epitaxial growth techniques, and stripe definition methods may all influence the radiation tolerance of the high power laser diode devices. Radiation tests have been conducted on various GaAs-GaAlAs laser diode array and broad area devices. Tests involving total gamma dose have indicated that high power laser diodes and arrays have small degradations in light power output with current input after 4 MRad(Si) of radiation from a Co 60 source. Additional test results involving flash x-rays indicate that high power diode lasers and arrays are tolerant to 10 12 rads(Si)/sec, when observed on microsecond or millisecond time scales. High power diode laser devices were also irradiated with neutrons to a fluence of 10 14 neutrons/cm 2 with some degradation of threshold current level

  14. Gas chromatography-mass spectrometry and high-performance liquid chromatographic analyses of thermal degradation products of common plastics

    OpenAIRE

    Pacakova, V.; Leclercq, P.A.

    1991-01-01

    The thermo-oxidation of five commonly used materials, namely low-density polyethylene, retarded polyethylene, paper with a polyethylene foil, a milk package and filled polypropylene, was studied. Capillary gas chromatography and gas chromatography-mass spectrometry were used to analyze the volatile degradation products, while high-performance liquid chromatography was employed to measure polycyclic aromatic hydrocarbons. The results are discussed from the point of view of toxicity of the prod...

  15. Simple and sensitive determination of atrazine and its toxic metabolites in environmental water by carboxyl modified polyacrylonitrile nanofibers mat-based solid-phase extraction coupled with liquid chromatography-diode array detection.

    Science.gov (United States)

    Cao, Weixin; Yang, Biyi; Qi, Feifei; Qian, Liangliang; Li, Jian; Lu, Lingeng; Xu, Qian

    2017-03-31

    Carboxyl modified polyacrylonitrile nanofibers mat (COOH-PAN NFsM) was prepared as a novel solid-phase extraction (SPE) adsorbent for the rapid and effective extraction of atrazine (ATZ) and its toxic metabolites deisopropylatrazine (DIA) and deethylatrazine (DEA) from environmental water samples. Without any pre-treatment but only with the simple filter, water samples passed through pre-conditioned COOH-PAN NFsM, which integrated extraction, purification and concentration into one single step, and the eluent was directly analyzed by high performance liquid chromatography-diode array detection (HPLC-DAD). Under the optimized conditions, the target analytes in 10mL of water sample could be completely extracted by only 4mg of COOH-PAN NFsM, and easily eluted using 400μL of methanol, indicating a high efficiency in both adsorption and desorption. Satisfactory linearity was achieved in the range of 0.4-40.0ngmL -1 for DIA, and 0.3-40.0ngmL -1 for DEA and ATZ. The limit of detection (LODs) were 0.12, 0.09 and 0.09ngmL -1 for DIA, DEA and ATZ, respectively. The recoveries ranged from 81.35 to 120.32%, with the intra-day and inter-day relative standard deviations of 4.03-9.81% even after the 6-cycle usage of NFsM. And, using just 10mL loading sample, the LOD had already satisfied the demand of surface water quality monitoring levels, revealing the good sensitivity of the proposed method. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Determination of oxymatrine in Sophora Radix by high performance liquid chromatography

    International Nuclear Information System (INIS)

    Yang, Seung Kwon; Yun, Young Ja; Namgung, Mi Ok

    2004-01-01

    A high performance liquid chromatographic method was designed for the quantitative analysis of oxymatrine in Sophora Radix. The separation of oxymatrine was performed by reversed-phase chromatography with a C 18 column and a buffered aqueous solution containing acetonitrile, and monitored by UV absorption at 215 nm. Extraction of oxymatrine in Sophora Radix was carried out using various solvents and extraction methods. The optimum extraction efficiency for the crushed Sophora Radix was achieved by reflux at 80 .deg. C in 50% ethanol for five hours. Most extraction methods used to complicate pretreatments. In this study, sublimation was employed for a extraction method without going through complicate pretreatments. Sublimation was carried out under high vacuum (1x10 -3 torr) and at high temperature (200 .deg. C). Extraction efficiency using Sublimation was found to be inferior to other extraction methods

  17. [Determination of lutein in infant formula milk powder using ultra-high performance liquid chromatography].

    Science.gov (United States)

    Wang, Lin; Huang, Junrong; Zhang, Li; Feng, Feng; Ling, Yun; Chu, Xiaogang; Li, Hongliang

    2013-12-01

    An ultra-high performance liquid chromatography (U-HPLC) method for the determination of lutein in the infant formula milk powder was developed. The sample was extracted with acetone and defatted using freezing centrifugation method. The U-HPLC separation was achieved using a YMC Carotenoid C30 column (150 mm x 4.6 mm, 3 microm) with the mixture of methanol/methyl tert-butyl ether (70: 30, v/v) as the mobile phase under isocratic elution. The flow rate was 0.5 mL/min and the column oven temperature was 25 degrees C. The injection volume was 5 microL. It was detected on a photodiode array detector at a wavelength of 445 nm. The results showed that the linear range was 20-500 microg/L (r = 0.9999), and the limit of quantification was 20 microg/L. The mean recoveries of lutein varied from 97.9% to 104.4% spiked at 50, 250 and 2,000 microg/kg. The established method is simple, accurate and sensitive for the rapid determination of lutein in infant formula milk powder.

  18. Quantitative Determination of Compounds from Akebia quinata by High-Performance Liquid Chromatography

    International Nuclear Information System (INIS)

    Yen, Nguyen; Thu, Nguyen; Zhao, Bing Tian; Woo, Mi Hee; Min, Byung Sun; Lee, Jae Hyun; Kim, Jeong Ah; Son, Jong Keun; Choi, Jae Sui; Woo, Eun Rhan

    2014-01-01

    To provide the scientific corroboration of the traditional uses of Akebia quinata (Thunb.) Decne., a detailed analytical examination of A. quinata stems was carried out using a reversed-phase high performance liquid chromatography (RP-HPLC) method coupled to photodiode array detector (PDA) for the simultaneous determination of four phenolic substances; cuneataside D, 2-(3,4-dihydroxyphenyl)ethyl-O-β-D-glucopyranoside, 3-caffeoylquinic acid and calceolarioside B. Particular attention was focused on the main compound, 3-caffeoylquinic acid, which has a range of biological functions. In addition, 2-(3,4-dihydroxyphenyl)ethyl-O-β-D-glucopyranoside was considered as a discernible marker of A. quinata from its easy confuse plants. The contents of compounds 2 and 3 ranged from 0.72 to 2.68 mg/g and from 1.66 to 5.64 mg/g, respectively. The validation data indicated that this HPLC/PDA assay was used successfully to quantify the four phenolic compounds in A. quinata from different locations using relatively simple conditions and procedures. The pattern-recognition analysis data from 53 samples classified them into two groups, allowing discrimination between A. quinata and comparable herbs. The results suggest that the established HPLC/PDA method is suitable for quantitation and pattern-recognition analyses for a quality evaluation of this medicinal herb

  19. Quantitative Determination of Compounds from Akebia quinata by High-Performance Liquid Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yen, Nguyen; Thu, Nguyen; Zhao, Bing Tian; Woo, Mi Hee; Min, Byung Sun [Catholic Univ. of Daegu, Gyeongsan (Korea, Republic of); Lee, Jae Hyun [Dongguk Univ., Yongin (Korea, Republic of); Kim, Jeong Ah [Kyungpook National Univ., Daegu (Korea, Republic of); Son, Jong Keun [Yeungnam Univ., Gyeongsan (Korea, Republic of); Choi, Jae Sui [Pukyung National Univ., Busan (Korea, Republic of); Woo, Eun Rhan [Chosun Univ., Gwangju (Korea, Republic of)

    2014-07-15

    To provide the scientific corroboration of the traditional uses of Akebia quinata (Thunb.) Decne., a detailed analytical examination of A. quinata stems was carried out using a reversed-phase high performance liquid chromatography (RP-HPLC) method coupled to photodiode array detector (PDA) for the simultaneous determination of four phenolic substances; cuneataside D, 2-(3,4-dihydroxyphenyl)ethyl-O-β-D-glucopyranoside, 3-caffeoylquinic acid and calceolarioside B. Particular attention was focused on the main compound, 3-caffeoylquinic acid, which has a range of biological functions. In addition, 2-(3,4-dihydroxyphenyl)ethyl-O-β-D-glucopyranoside was considered as a discernible marker of A. quinata from its easy confuse plants. The contents of compounds 2 and 3 ranged from 0.72 to 2.68 mg/g and from 1.66 to 5.64 mg/g, respectively. The validation data indicated that this HPLC/PDA assay was used successfully to quantify the four phenolic compounds in A. quinata from different locations using relatively simple conditions and procedures. The pattern-recognition analysis data from 53 samples classified them into two groups, allowing discrimination between A. quinata and comparable herbs. The results suggest that the established HPLC/PDA method is suitable for quantitation and pattern-recognition analyses for a quality evaluation of this medicinal herb.

  20. Detection of argan oil adulteration with vegetable oils by high-performance liquid chromatography-evaporative light scattering detection.

    Science.gov (United States)

    Salghi, Rachid; Armbruster, Wolfgang; Schwack, Wolfgang

    2014-06-15

    Triacylglycerol profiles were selected as indicator of adulteration of argan oils to carry out a rapid screening of samples for the evaluation of authenticity. Triacylglycerols were separated by high-performance liquid chromatography-evaporative light scattering detection. Different peak area ratios were defined to sensitively detect adulteration of argan oil with vegetable oils such as sunflower, soy bean, and olive oil up to the level of 5%. Based on four reference argan oils, mean limits of detection and quantitation were calculated to approximately 0.4% and 1.3%, respectively. Additionally, 19 more argan oil reference samples were analysed by high-performance liquid chromatography-refractive index detection, resulting in highly comparative results. The overall strategy demonstrated a good applicability in practise, and hence a high potential to be transferred to routine laboratories. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. DETERMINATION AND COMPARISON OF MAJOR POLYPHENOL OF FOUR RED FRUITS USING HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC WITH DIODE-ARRAY DETECTION

    Directory of Open Access Journals (Sweden)

    Khatereh Khorsandi

    2013-12-01

    Full Text Available Polyphenols are ubiquitous compounds in plants which are abundant micronutrients in our diet. They got more attention in recent years due to their bioactive functions and health effects on many diseases such as cancer. These components are secondary plant metabolites that function as antimicrobial, antiviral and anti-inflammatory compounds. Extraction of these compounds from plants and fruits and in vitro and in vivo study of their various health effects has been subject of many researches. The objective of this study was to investigate the profiles of polyphenolic compounds in apple, red grape, sour cherry and pomegranate fruit juices and comparison of the phenolic contents of various juices. Major polyphenolic compounds of four different concentrated fruit juices from various industries were analyzed and characterized by liquid chromatography. RP-HPLC-DAD was used in our study as powerful and accurate method. The total and individual polyphenolic compounds differed significantly among the four selected red fruit juices. Among the tested juices, sour cherry and apple juices had the highest and the lowest contents of phenolic compounds, respectively.

  2. Determination of low molecular weight thiols using monobromobimane fluorescent labeling and high-performance liquid chromatography

    Science.gov (United States)

    Fahey, Robert C.; Newton, Gerald L.

    1988-01-01

    Methods are described for the preparation and high-performance liquid chromatography (HPLC) analysis of monobromobimane derivatives of low molecular weight thiols in extracts of biological samples. Typical problems encountered in the development and application of these methods are discussed. Analysis of mung bean extract is used as an example.

  3. Advancement of High Power Quasi-CW Laser Diode Arrays For Space-based Laser Instruments

    Science.gov (United States)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, nathaniel R.; Baggott, Renee S.; Singh, Upendra N.; Kavaya, Michael J.

    2004-01-01

    Space-based laser and lidar instruments play an important role in NASA s plans for meeting its objectives in both Earth Science and Space Exploration areas. Almost all the lidar instrument concepts being considered by NASA scientist utilize moderate to high power diode-pumped solid state lasers as their transmitter source. Perhaps the most critical component of any solid state laser system is its pump laser diode array which essentially dictates instrument efficiency, reliability and lifetime. For this reason, premature failures and rapid degradation of high power laser diode arrays that have been experienced by laser system designers are of major concern to NASA. This work addresses these reliability and lifetime issues by attempting to eliminate the causes of failures and developing methods for screening laser diode arrays and qualifying them for operation in space.

  4. Analysis of major antioxidants from extracts of Myrmecodia pendans by UV/visible spectrophotometer, liquid chromatography/tandem mass spectrometry, and high-performance liquid chromatography/UV techniques.

    Science.gov (United States)

    Engida, Adam Mekonnen; Faika, Sitti; Nguyen-Thi, Bich Thuyen; Ju, Yi-Hsu

    2015-06-01

    In the present work, heat reflux extraction with ethanol/water (80:20; v/v) as the solvent was used to extract antioxidants from Myrmecodia pendans. The crude extract (CE) was fractionated using hexane and ethyl acetate. Ethyl acetate fraction (EAF) and aqueous fraction were collected. Antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power of the CE, EAF, and aqueous fraction were evaluated. EAF showed comparable antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power to those of the CE. UV/visible, liquid chromatography/electrospray ionization/tandem mass spectrometry, and high-performance liquid chromatography were employed for identifying the major antioxidant compounds in the EAF. Three major phenolic compounds (rosmarinic acid, procyanidin B1, and polymer of procyanidin B1) were identified. The first two compounds were confirmed and quantified by high-performance liquid chromatography using authentic standards, but confirmation of the third compound was hampered by a lack of commercial standard. Concentrations of rosmarinic acid and procyanidin B1 in the EAF were found to be 20.688 ± 1.573 mg/g dry sample and 3.236 ± 0.280 mg/g dry sample, respectively. All these three compounds are reported for the first time in sarang semut. Copyright © 2014. Published by Elsevier B.V.

  5. Analysis of major antioxidants from extracts of Myrmecodia pendans by UV/visible spectrophotometer, liquid chromatography/tandem mass spectrometry, and high-performance liquid chromatography/UV techniques

    Directory of Open Access Journals (Sweden)

    Adam Mekonnen Engida

    2015-06-01

    Full Text Available In the present work, heat reflux extraction with ethanol/water (80:20; v/v as the solvent was used to extract antioxidants from Myrmecodia pendans. The crude extract (CE was fractionated using hexane and ethyl acetate. Ethyl acetate fraction (EAF and aqueous fraction were collected. Antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power of the CE, EAF, and aqueous fraction were evaluated. EAF showed comparable antioxidant activity against 1,1-diphenyl-2-picrylhydrazyl-radical radical and ferric reducing power to those of the CE. UV/visible, liquid chromatography/electrospray ionization/tandem mass spectrometry, and high-performance liquid chromatography were employed for identifying the major antioxidant compounds in the EAF. Three major phenolic compounds (rosmarinic acid, procyanidin B1, and polymer of procyanidin B1 were identified. The first two compounds were confirmed and quantified by high-performance liquid chromatography using authentic standards, but confirmation of the third compound was hampered by a lack of commercial standard. Concentrations of rosmarinic acid and procyanidin B1 in the EAF were found to be 20.688 ± 1.573 mg/g dry sample and 3.236 ± 0.280 mg/g dry sample, respectively. All these three compounds are reported for the first time in sarang semut.

  6. Simultaneous determination of estrogens and progestogens in honey using high performance liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    This work describes the development and validation of a method for the simultaneous determination of 13 estrogens and progestogens in honey by high performance liquid chromatography-tandem mass spectrometry. The target compounds were preconcentrated by solid phase extraction. Pretreatment variables ...

  7. Determination of methyldibromoglutaronitrile in cosmetic products by high-performance liquid chromatography with electrochemical detection. Method validation

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Zachariae, Claus; Johansen, Jeanne D

    2004-01-01

    An increased frequency of contact allergy to methyldibromoglutaronitrile (MDBGN), a commonly used preservative in cosmetics and other consumer products, has been reported in recent years. A high-performance liquid chromatography (HPLC) method for the determination of MDBGN in cosmetic products has...

  8. Determination of methyldibromoglutaronitrile in cosmetic products by high-performance liquid chromatography with electrochemical detection. Method validation

    DEFF Research Database (Denmark)

    Rastogi, Suresh Chandra; Zachariae, Claus; Johansen, Jeanne D

    2004-01-01

    An increased frequency of contact allergy to methyldibromoglutaronitrile (MDBGN), a commonly used preservative in cosmetics and other consumer products, has been reported in recent years. A high-performance liquid chromatography (HPLC) method for the determination of MDBGN in cosmetic products ha...

  9. Simultaneous determination of eperisone hydrochloride and paracetamol in mouse plasma by high performance liquid chromatography-photodiode array detector.

    Science.gov (United States)

    Locatelli, Marcello; Cifelli, Roberta; Di Legge, Cristina; Barbacane, Renato Carmine; Costa, Nicola; Fresta, Massimo; Celia, Christian; Capolupo, Carlo; Di Marzio, Luisa

    2015-04-03

    This paper reports the validation of a quantitative high performance liquid chromatography-photodiode array (HPLC-PDA) method for the simultaneous analysis, in mouse plasma, of eperisone hydrochloride and paracetamol by protein precipitation using zinc sulphate-methanol-acetonitrile. The analytes were resolved on a Gemini C18 column (4.6 mm × 250 mm; 5 μm particle size) using a gradient elution mode with a run time of 15 min, comprising re-equilibration, at 60°C (± 1°C). The method was validated over the concentration range from 0.5 to 25 μg/mL for eperisone hydrochloride and paracetamol, in mouse plasma. Ciprofloxacin was used as Internal Standard. Results from assay validations show that the method is selective, sensitive and robust. The limit of quantification of the method was 0.5 μg/mL for eperisone hydrochloride and paracetamol, and matrix-matched standard curves showed a good linearity, up to 25 μg/mL with correlation coefficients (r(2))≥ 0.9891. In the entire analytical range the intra and inter-day precision (RSD%) values were ≤ 1.15% and ≤ 1.46% for eperisone hydrochloride, and ≤ 0.35% and ≤ 1.65% for paracetamol. For both analytes the intra and inter-day trueness (bias%) values ranged, respectively, from -5.33% to 4.00% and from -11.4% to -4.00%. The method was successfully tested in pharmacokinetic studies after oral administration in mouse. Furthermore, the application of this method results in a significant reduction in terms of animal number, dosage, and improvement in speed, rate of analysis, and quality of pharmacokinetic parameters related to serial blood sampling. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Determination of sulfonamides in butter samples by ionic liquid magnetic bar liquid-phase microextraction high-performance liquid chromatography.

    Science.gov (United States)

    Wu, Lijie; Song, Ying; Hu, Mingzhu; Xu, Xu; Zhang, Hanqi; Yu, Aimin; Ma, Qiang; Wang, Ziming

    2015-01-01

    A novel, simple, and environmentally friendly pretreatment method, ionic liquid magnetic bar liquid-phase microextraction, was developed for the determination of sulfonamides in butter samples by high-performance liquid chromatography. The ionic liquid magnetic bar was prepared by inserting a stainless steel wire into the hollow of a hollow fiber and immobilizing ionic liquid in the micropores of the hollow fiber. In the extraction process, the ionic liquid magnetic bars were used to stir the mixture of sample and extraction solvent and enrich the sulfonamides in the mixture. After extraction, the analyte-adsorbed ionic liquid magnetic bars were readily isolated with a magnet from the extraction system. It is notable that the present method was environmentally friendly since water and only several microliters of ionic liquid were used in the whole extraction process. Several parameters affecting the extraction efficiency were investigated and optimized, including the type of ionic liquid, sample-to-extraction solvent ratio, the number of ionic liquid magnetic bars, extraction temperature, extraction time, salt concentration, stirring speed, pH of the extraction solvent, and desorption conditions. The recoveries were in the range of 73.25-103.85 % and the relative standard deviations were lower than 6.84 %. The experiment results indicated that the present method was effective for the extraction of sulfonamides in high-fat content samples.

  11. Analytical Issues on the Determination of Carotenoids in Microalgae by Liquid Chromatography with Diode Array Detector

    International Nuclear Information System (INIS)

    Garcia, S.; Perez, R. M.

    2012-01-01

    A preliminary study of literature review on the determination of carotenoids in microalgae samples by HPLC with diode array detector is presented. Main objective has been focused to compile data from literature and based on the main aspects of the analytical methodology used in the determination of these compounds. The work is structured as follows and affecting major analytical difficulties: Procurement and commercial availability of standard solutions. Stage of sample treatment. Chromatographic analysis. (Author) 19 refs.

  12. Comparison of ultra-high performance supercritical fluid chromatography and ultra-high performance liquid chromatography for the separation of spirostanol saponins.

    Science.gov (United States)

    Zhu, Ling-Ling; Zhao, Yang; Xu, Yong-Wei; Sun, Qing-Long; Sun, Xin-Guang; Kang, Li-Ping; Yan, Ren-Yi; Zhang, Jie; Liu, Chao; Ma, Bai-Ping

    2016-02-20

    Spirostanol saponins are important active components of some herb medicines, and their isolation and purification are crucial for the research and development of traditional Chinese medicines. We aimed to compare the separation of spirostanol saponins by ultra-high performance supercritical fluid chromatography (UHPSFC) and ultra-high performance liquid chromatography (UHPLC). Four groups of spirostanol saponins were separated respectively by UHPSFC and UHPLC. After optimization, UHPSFC was performed with a HSS C18 SB column or a Diol column and with methanol as the co-solvent. A BEH C18 column and mobile phase containing water (with 0.1% formic acid) and acetonitrile were used in UHPLC. We found that UHPSFC could be performed automatically and quickly. It is effective in separating the spirostanol saponins which share the same aglycone and vary in sugar chains, and is very sensitive to the number and the position of hydroxyl groups in aglycones. However, the resolution of spirostanol saponins with different aglycones and the same sugar moiety by UHPSFC was not ideal and could be resolved by UHPLC instead. UHPLC is good at differentiating the variation in aglycones, and is influenced by double bonds in aglycones. Therefore, UHPLC and UHPSFC are complementary in separating spirostanol saponins. Considering the naturally produced spirostanol saponins in herb medicines are different both in aglycones and in sugar chains, a better separation can be achieved by combination of UHPLC and UHPSFC. UHPSFC is a powerful technique for improving the resolution when UHPLC cannot resolve a mixture of spirostanol saponins and vice versa. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Identification and Quantitation of Asparagine and Citrulline Using High-Performance Liquid Chromatography (HPLC)

    OpenAIRE

    Bai, Cheng; Reilly, Charles C.; Wood, Bruce W.

    2007-01-01

    High-performance liquid chromatography (HPLC) analysis was used for identification of two problematic ureides, asparagine and citrulline. We report here a technique that takes advantage of the predictable delay in retention time of the co-asparagine/citrulline peak to enable both qualitative and quantitative analysis of asparagine and citrulline using the Platinum EPS reverse-phase C18 column (Alltech Associates). Asparagine alone is eluted earlier than citrulline alone, but when both of them...

  14. High-performance liquid chromatography analysis methods developed for quantifying enzymatic esterification of flavonoids in ionic liquids.

    Science.gov (United States)

    Lue, Bena-Marie; Guo, Zheng; Xu, Xuebing

    2008-07-11

    Methods using reversed-phase high-performance liquid chromatography (RP-HPLC) with ELSD were investigated to quantify enzymatic reactions of flavonoids with fatty acids in the presence of diverse room temperature ionic liquids (RTILs). A buffered salt (preferably triethylamine-acetate) was found essential for separation of flavonoids from strongly polar RTILs, whereby RTILs were generally visible as two major peaks identified based on an ion-pairing/exchanging hypothesis. C8 and C12 stationary phases were optimal while mobile phase pH (3-7) had only a minor influence on separation. The method developed was successfully applied for primary screening of RTILs (>20), with in depth evaluation of substrates in 10 RTILs, for their evaluation as reaction media.

  15. Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications

    Science.gov (United States)

    Preti, Raffaella

    2016-01-01

    The increased separation efficiency provided by the new technology of column packed with core-shell particles in high-performance liquid chromatography (HPLC) has resulted in their widespread diffusion in several analytical fields: from pharmaceutical, biological, environmental, and toxicological. The present paper presents their most recent applications in food analysis. Their use has proved to be particularly advantageous for the determination of compounds at trace levels or when a large amount of samples must be analyzed fast using reliable and solvent-saving apparatus. The literature hereby described shows how the outstanding performances provided by core-shell particles column on a traditional HPLC instruments are comparable to those obtained with a costly UHPLC instrumentation, making this novel column a promising key tool in food analysis. PMID:27143972

  16. Optimization of the combination micro-high-performance liquid-chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Haider, K.

    1997-03-01

    The coupling of liquid chromatography and mass spectrometry is still growing in significance. In this thesis, a particle beam interface has been investigated for combining ion chromatography with mass spectrometric detection. To introduce the eluent directly (without membrane suppressor) into the spectrometer, only methods with low flow rates like microcolumn chromatography can be used. For the preparation of the columns, reversed-phase and silica-based anion exchange materials were packed into PEEK, steel and fused-silica capillaries with i.d. from 130 to 1000 μm using different methods. The performance of the particle beam interface (modified with a new miniaturized aerosol generator) and the mass spectrometric detection has been studied for a series of inorganic anions as well as aminopolycarboxylic acids and the metal-EDTA complexes. Detection limits between 10 and 100 ng injected could be achieved in the multiple ion detection mode of the mass spectrometer for the investigated solutes. A second type of interface, the direct liquid introduction (DLI) has been used to analyze the priority pollutant phenols. This interface is based on a modified GC-interface into the MS. Separation columns used so far include packed fused-silica capillaries with inner diameter of 75 μm and polystyrene-divinylbenzene (functionalized with tert. butyl groups) as stationary phase. Aspects of instrumentation and effects of chemical ionization in the direct liquid introduction mode are discussed. (author)

  17. Application of high performance liquid chromatography for the profiling of complex chemical mixtures with the aid of chemometrics.

    Science.gov (United States)

    Ni, Yongnian; Zhang, Liangsheng; Churchill, Jane; Kokot, Serge

    2007-06-15

    In this paper, chemometrics methods were applied to resolve the high performance liquid chromatography (HPLC) fingerprints of complex, many-component substances to compare samples from a batch from a given manufacturer, or from those of different producers. As an example of such complex substances, we used a common Chinese traditional medicine, Huoxiang Zhengqi Tincture (HZT) for this research. Twenty-one samples, each representing a separate HZT production batch from one of three manufacturers were analyzed by HPLC with the aid of a diode array detector (DAD). An Agilent Zorbax Eclipse XDB-C18 column with an Agilent Zorbax high pressure reliance cartridge guard-column were used. The mobile phase consisted of water (A) and methanol (B) with a gradient program of 25-65% (v/v, B) during 0-30min, 65-55% (v/v, B) during 30-35min and 55-100% (v/v, B) during 35-60min (flow rate, 1.0mlmin(-1); injection volume, 20mul; and column temperature-ambient). The detection wavelength was adjusted for maximum sensitivity at different time periods. A peak area matrix with 21objectsx14HPLC variables was obtained by sampling each chromatogram at 14 common retention times. Similarities were then calculated to discriminate the batch-to-batch samples and also, a more informative multi-criteria decision making methodology (MCDM), PROMETHEE and GAIA, was applied to obtain more information from the chromatograms in order to rank and compare the complex HZT profiles. The results showed that with the MCDM analysis, it was possible to match and discriminate correctly the batch samples from the three different manufacturers. Fourier transform infrared (FT-IR) spectra taken from samples from several batches were compared by the common similarity method with the HPLC results. It was found that the FT-IR spectra did not discriminate the samples from the different batches.

  18. Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

    OpenAIRE

    Chandrashekar, Vani

    2016-01-01

    Hb A1c measurement is subject to interference by hemoglobin traits and this is dependent on the method used for determination. In this paper we studied the difference between Hb A1c measured by HPLC in hemoglobin traits and normal chromatograms. We also studied the correlation of Hb A1c with age. Hemoglobin analysis was carried out by high performance liquid chromatography. Spearman's rank correlation was used to study correlation between A1c levels and age. Mann-Whitney U test was used to st...

  19. Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1993-01-01

    A high-performance liquid chromatography (HPLC)/fluorescence method for quantitative analysis of 1-hydroxypyrene in urine was developed. The method validation analysis showed the method to be in analytical control. No significant systematical errors could be demonstrated. The entire run time....... The developed method is presently used for measurement of 1-hydroxypyrene in urine samples from workers exposed to a low airborne level of polycyclic aromatic hydrocarbons, generally less than 25 micrograms/m3. The urine samples of exposed workers (n = 122) showed a range of 1-hydroxypyrene from the limit...

  20. Evaluation of Drying Process on the Composition of Black Pepper Ethanolic Extract by High Performance Liquid Chromatography With Diode Array Detector

    Science.gov (United States)

    Namjoyan, Foroogh; Hejazi, Hoda; Ramezani, Zahra

    2012-01-01

    Background Black pepper (Piper nigrum) is one of the well-known spices extensively used worldwide especially in India, and Southeast Asia. The presence of alkaloids in the pepper, namely, piperine and its three stereoisomers, isopiperine, chavicine and isochavicine are well noticed. Objectives The current study evaluated the effect of lyophilization and oven drying on the stability and decomposition of constituents of black pepper ethanolic extract. Materials and Methods In the current study ethanolic extract of black pepper obtained by maceration method was dried using two methods. The effect of freeze and oven drying on the chemical composition of the extract especially piperine and its three isomers were evaluated by HPLC analysis of the ethanolic extract before and after drying processes using diode array detector. The UV Vis spectra of the peaks at piperine retention time before and after each drying methods indicated maximum absorbance at 341.2 nm corresponding to standard piperine. Results The results indicated a decrease in intensity of the chromatogram peaks at approximately all retention times after freeze drying, indicating a few percent loss of piperine and its isomers upon lyophilization. Two impurity peaks were completely removed from the extract. Conclusions In oven dried samples two of the piperine stereoisomers were completely removed from the extract and the intensity of piperine peak was increased. PMID:24624176

  1. Synthesis of monodisperse silica microspheres and modification with diazoresin for mixed-mode ultra high performance liquid chromatography separations.

    Science.gov (United States)

    Cong, Hailin; Yu, Bing; Tian, Chao; Zhang, Shuai; Yuan, Hua

    2017-11-01

    Monodisperse silica particles with average diameters of 1.9-2.9 μm were synthesized by a modified Stöber method, in which tetraethyl orthosilicate was continuously supplied to the reaction mixture containing KCl electrolyte, water, ethanol, and ammonia. The obtained silica particles were modified by self-assembly with positively charged photosensitive diazoresin on the surface. After treatment with ultraviolet light, the ionic bonding between silica and diazoresin was converted into covalent bonding through a unique photochemistry reaction of diazoresin. Depending on the chemical structure of diazoresin and mobile phase composition, the diazoresin-modified silica stationary phase showed different separation mechanisms, including reversed phase and hydrophilic interactions. Therefore, a variety of baseline separation of benzene analogues and organic acids was achieved by using the diazoresin-modified silica particles as packing materials in ultra high performance liquid chromatography. According to the π-π interactional difference between carbon rings of fullerenes and benzene rings of diazoresin, C 60 and C 70 were also well separated by ultra-high performance liquid chromatography. Because it has a small size, the ∼2.5 μm monodisperse diazoresin-modified silica stationary phase shows ultra-high efficiency compared with the commercial C 18 -silica high-performance liquid chromatography stationary phase with average diameters of ∼5 μm. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Analysis of Free Amino Acids in Different Extracts of Orthosiphon stamineus Leaves by High-Performance Liquid Chromatography Combined with Solid-Phase Extraction.

    Science.gov (United States)

    Shafaei, Armaghan; Halim, Nor Hidayah Ab; Zakaria, Norhidayah; Ismail, Zhari

    2017-10-01

    Orthosiphon stamineus (OS) Benth is a medicinal plant and native in Southeast Asia. Previous studies have shown that OS leaves possess antioxidant, cytotoxic, diuretic, antihypertensive, and uricosuric effects. These beneficial effects have been attributed to the presence of primary and secondary metabolites such as polyphenols, amino acids, and flavonoids. To develop and validate an high-performance liquid chromatography (HPLC)-diode array detector (DAD) method combined with solid-phase extraction that involves precolumn derivatization with O -phthaladehyde for simultaneous analysis of free amino acids in OS leaves extracts. OS leaves were extracted with water (OS-W), ethanol (OS-E), methanol (OS-M), 50% ethanol (OS-EW), and 50% methanol (OS-MW). The extracts were treated by C18 cartridge before derivatization, resulting in great improvement of separation by Zorbox Eclipse XDB-C 18 column. The HPLC-DAD method was successfully developed and validated for analyzing the contents of free amino acids in OS extracts. The results showed that l-aspartic acid with 0.93 ± 0.01 nmol/mg was the major free amino acid in OS-W extract. However, in OS-E, OS-M, OS-EW, and OS-MW, l-glutamic acid with 3.53 ± 0.16, 2.17 ± 0.10, 4.01 ± 0.12, and 2.49 ± 0.12 nmol/mg, respectively, was the major free amino acid. Subsequently, l-serine, which was detected in OS-W, OS-E, and OS-M, was the minor free amino acid with 0.33 ± 0.02, 0.12 ± 0.01, and 0.06 ± 0.01 nmol/mg, respectively. However, l-threonine with 0.26 ± 0.02 and 0.19 ± 0.08 nmol/mL in OS-EW and OS-MW, respectively, had the lowest concentration compared with other amino acid components. All validation parameters of the developed method indicate that the method is reliable and efficient to simultaneously determine the free amino acids content for routine analysis of OS extracts. The HPLC-DAD method combined with solid phase extraction was successfully developed and validated for simultaneous determination and

  3. Purification of a 166mHo solution by successive high-performance liquid chromatography and gravitational chromatography for half-life determination

    International Nuclear Information System (INIS)

    Florence Gueguen; Helene Isnard; Carole Bresson; Celine Caussignac; Guillaume Stadelmann; Anthony Nonell; Sebastien Mialle; Karsten Kossert; Frederic Chartier

    2014-01-01

    A methodology to purify a 166m Ho solution has been developed by a combination of activity and mass concentration measurements in order to further determine the 166m Ho half-life. The isobaric interference at m/q ≃ 166 requires Ho purification from non-natural Er with a high purification degree due to the large amount of Ho as opposed to Er. The Ho/Er separation was achieved using high-performance liquid chromatography on a semi-preparative column followed by purification on gravitational chromatography. The efficiency of the separation was evaluated after precise determination of the Er isotopic composition. The purification methodology enabled to separate Ho from Er. (author)

  4. Constructing a LabVIEW-Controlled High-Performance Liquid Chromatography (HPLC) System: An Undergraduate Instrumental Methods Exercise

    Science.gov (United States)

    Smith, Eugene T.; Hill, Marc

    2011-01-01

    In this laboratory exercise, students develop a LabVIEW-controlled high-performance liquid chromatography system utilizing a data acquisition device, two pumps, a detector, and fraction collector. The programming experience involves a variety of methods for interface communication, including serial control, analog-to-digital conversion, and…

  5. One single standard substance for the simultaneous determination of 17 triterpenes in Ganoderma lingzhi and its related species using high-performance liquid chromatography.

    Science.gov (United States)

    Liu, Wei; Zhang, Jingsong; Han, Wei; Liu, Yanfang; Feng, Jie; Tang, Chuanhong; Feng, Na; Tang, Qingjiu

    2017-11-15

    Due to the difficulty and high cost for the preparation of triterpenes, one single standard for the simultaneous determination of multi-components (SSDMC) with high performance liquid chromatography (HPLC) is an advanced solution for multi-component analysis. Experiments were carried out to investigate the feasibility of SSDMC for the analysis of Ganoderma triterpenes, with external standard method (ESM) compared, and the samples of Ganoderma were classified by the content of Ganoderma triterpenes. The analysis was performed by using a Fortis Speed Core-C18 column (150mm×4.6mm I.D., 2.6μm) at gradient elution of 0.01% glacial acetic acid-water (V/V) and acetonitrile with diode array detection (252nm), at a flow rate of 1mL/min. The results showed that all calibration curves had good linearity (r 2 >0.9999) within test ranges. The LOD and LOQ were lower than 2.52ng and 6.43ng, respectively. The RSD for intra-day and inter-day of the seventeen analytes were less than 3.12% at three levels, and the recoveries were 91.4-103.0%. The contents of other 16 triterpenes were determined with ganoderic acid A by SSDMC, which showed that there were few differences compared with the results obtained by ESM. Moreover, the classification of 25 different species and strains of Ganoderma by using the content of triterpenes intuitively reflected the distinction among Ganoderma. In summary, the developed method could be readily utilized as a method of quality evaluation for Ganoderma triterpenes. Copyright © 2017. Published by Elsevier B.V.

  6. Microchip-based monolithic column for high performance liquid chromatography

    Data.gov (United States)

    National Aeronautics and Space Administration — We have developed microchip based monolithic columns that can be used for liquid chromatography of small organic molecules, as well as, macromolecules such as...

  7. Quantitation of bilirubin conjugates with high-performance liquid chromatography in patients with low total serum bilirubin levels

    NARCIS (Netherlands)

    Jansen, P. L.; Cuypers, H. T.; Peters, W. H.

    1984-01-01

    Bilirubin mono- and diconjugates were determined by alkaline methanolysis and high-performance liquid chromatography (HPLC) in serum from patients with metastatic liver disease and liver cirrhosis. Conjugates could be detected and quantitated at normal or low total bilirubin levels. Comparison with

  8. Identification and quantification of cannabinoids in Cannabis sativa L. plants by high performance liquid chromatography-mass spectrometry

    NARCIS (Netherlands)

    Aizpurua-Olaizola, Oier; Omar, Jone; Navarro, Patricia; Olivares, Maitane; Etxebarria, Nestor; Usobiaga, Aresatz

    2014-01-01

    High performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) has been successfully applied to cannabis plant extracts in order to identify cannabinoid compounds after their quantitative isolation by means of supercritical fluid extraction (SFE). MS conditions were optimized by means

  9. Toxic Compounds Analysis With High Performance Liquid Chromatography Detected By Electro Chemical Detector (Ecd)

    OpenAIRE

    Hideharu Shintaniq

    2014-01-01

    The principal area of application of high performance liquid chromatography-electrochemical detector (HPLC-ECD) has been in the analysis of naturally-occurring analytes, such as catecholamines, and pharmaceuticals in biological samples, HPLC-ECD has also applied to the analysis of pesticides and other analytes of interest to the toxicologist. In this paper, toxic area is described. In these, ammatoxins, aromatic amine, nitro-compounds, algal toxins, fungal toxins, pesticides, veterinary drug ...

  10. Ultra‐high performance supercritical fluid chromatography of lignin‐derived phenols from alkaline cupric oxide oxidation

    Science.gov (United States)

    Sun, Mingzhe; Lidén, Gunnar; Sandahl, Margareta

    2016-01-01

    Traditional chromatographic methods for the analysis of lignin‐derived phenolic compounds in environmental samples are generally time consuming. In this work, an ultra‐high performance supercritical fluid chromatography method with a diode array detector for the analysis of major lignin‐derived phenolic compounds produced by alkaline cupric oxide oxidation was developed. In an analysis of a collection of 11 representative monomeric lignin phenolic compounds, all compounds were clearly separated within 6 min with excellent peak shapes, with a limit of detection of 0.5–2.5 μM, a limit of quantification of 2.5–5.0 μM, and a dynamic range of 5.0–2.0 mM (R 2 > 0.997). The new ultra‐high performance supercritical fluid chromatography method was also applied for the qualitative and quantitative analysis of lignin‐derived phenolic compounds obtained upon alkaline cupric oxide oxidation of a commercial humic acid. Ten out of the previous eleven model compounds could be quantified in the oxidized humic acid sample. The high separation power and short analysis time obtained demonstrate for the first time that supercritical fluid chromatography is a fast and reliable technique for the analysis of lignin‐derived phenols in complex environmental samples. PMID:27452148

  11. Instrumental liquid chromatography: a practical manual on high-performance liquid chromatographic methods

    National Research Council Canada - National Science Library

    Parris, N. A

    1976-01-01

    Available texts on liquid chromatography have tended to emphasize the developments in the theoretical understanding of the technique and methodology or to list numerous applications, complete with experimental details...

  12. NONLINEAR-REGRESSION METHODS FOR MODELING OF HETEROSCEDASTIC RETENTION DATA IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    HENDRIKS, MMWB; COENEGRACHT, PMJ; DOORNBOS, DA

    1994-01-01

    New models have been developed that accurately describe the response surfaces of capacity factors that are a function of changes in the pH and the fraction of organic modifier in reversed-phase high-performance liquid chromatography (RP-HPLC). The purpose of this article is to illustrate one of the

  13. Neutral monosaccharide composition analysis of plant-derived oligo- and polysaccharides by high performance liquid chromatography.

    Science.gov (United States)

    Yan, Jun; Shi, Songshan; Wang, Hongwei; Liu, Ruimin; Li, Ning; Chen, Yonglin; Wang, Shunchun

    2016-01-20

    A novel analytical method for neutral monosaccharide composition analysis of plant-derived oligo- and polysaccharides was developed using hydrophilic interaction liquid chromatography coupled to a charged aerosol detector. The effects of column type, additives, pH and column temperature on retention and separation were evaluated. Additionally, the method could distinguish potential impurities in samples, including chloride, sulfate and sodium, from sugars. The results of validation demonstrated that this method had good linearity (R(2) ≥ 0.9981), high precision (relative standard deviation ≤ 4.43%), and adequate accuracy (94.02-103.37% recovery) and sensitivity (detection limit: 15-40 ng). Finally, the monosaccharide compositions of the polysaccharide from Eclipta prostrasta L. and stachyose were successfully profiled through this method. This report represents the first time that all of these common monosaccharides could be well-separated and determined simultaneously by high performance liquid chromatography without additional derivatization. This newly developed method is convenient, efficient and reliable for monosaccharide analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Ionic-liquid-based ultrasound-assisted extraction of isoflavones from Belamcanda chinensis and subsequent screening and isolation of potential α-glucosidase inhibitors by ultrafiltration and semipreparative high-performance liquid chromatography.

    Science.gov (United States)

    Li, Senlin; Li, Sainan; Huang, Yu; Liu, Chunming; Chen, Lina; Zhang, Yuchi

    2017-06-01

    The separation of a compound of interest from its structurally similar homologues to produce high-purity natural products is a challenging problem. This work proposes a novel method for the separation of iristectorigenin A from its structurally similar homologues by ionic-liquid-based ultrasound-assisted extraction and the subsequent screening and isolation of potential α-glucosidase inhibitors via ultrafiltration and semipreparative high-performance liquid chromatography. Ionic-liquid-based ultrasound-assisted extraction was successfully applied to the extraction of tectorigenin, iristectorigenin A, irigenin, and irisflorentin from Belamcanda chinensis. The optimum conditions for the efficient extraction of isoflavones were determined as 1.0 M 1-ethyl-3-methylimidazolium tetrafluoroborate with extraction time of 30 min and a solvent to solid ratio of 30 mL/g. Ultrafiltration with liquid chromatography and mass spectrometry was applied to screen and identify α-glucosidase inhibitors from B. chinensis, followed by the application of semipreparative high-performance liquid chromatography to separate and isolate the active constituents. Four major compounds including tectorigenin, iristectorigenin A, irigenin, and irisflorentin were screened and identified as α-glucosidase inhibitors, and then the four active compounds abovementioned were subsequently isolated by semipreparative high-performance liquid chromatography (99.89, 88.97, 99.79, and 99.97% purity, respectively). The results demonstrate that ionic liquid extraction can be successfully applied to the extraction of isoflavones from B. chinensis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Ultra-sensitive high performance liquid chromatography-laser-induced fluorescence based proteomics for clinical applications.

    Science.gov (United States)

    Patil, Ajeetkumar; Bhat, Sujatha; Pai, Keerthilatha M; Rai, Lavanya; Kartha, V B; Chidangil, Santhosh

    2015-09-08

    An ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique has been developed by our group at Manipal, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from volunteers (normal, and different pre-malignant/malignant conditions) were recorded using this set-up. The protein profiles were analyzed using principal component analysis (PCA) to achieve objective detection and classification of malignant, premalignant and healthy conditions with high sensitivity and specificity. The HPLC-LIF protein profiling combined with PCA, as a routine method for screening, diagnosis, and staging of cervical cancer and oral cancer, is discussed in this paper. In recent years, proteomics techniques have advanced tremendously in life sciences and medical sciences for the detection and identification of proteins in body fluids, tissue homogenates and cellular samples to understand biochemical mechanisms leading to different diseases. Some of the methods include techniques like high performance liquid chromatography, 2D-gel electrophoresis, MALDI-TOF-MS, SELDI-TOF-MS, CE-MS and LC-MS techniques. We have developed an ultra-sensitive high performance liquid chromatography-laser induced fluorescence (HPLC-LIF) based technique, for screening, early detection, and staging for various cancers, using protein profiling of clinical samples like, body fluids, cellular specimens, and biopsy-tissue. More than 300 protein profiles of different clinical samples (serum, saliva, cellular samples and tissue homogenates) from healthy and volunteers with different malignant conditions were recorded by using this set-up. The protein profile data were analyzed using principal component analysis (PCA) for objective

  16. Design and implementation of an array of micro-electrochemical detectors for two-dimensional liquid chromatography--proof of principle.

    Science.gov (United States)

    Abia, Jude A; Putnam, Joel; Mriziq, Khaled; Guiochon, Georges A

    2010-03-05

    Simultaneous two-dimensional liquid chromatography (2D-LC) is an implementation of two-dimensional liquid chromatography which has the potential to provide very fast, yet highly efficient separations. It is based on the use of time x space and space x space separation systems. The basic principle of this instrument has been validated long ago by the success of two-dimensional thin layer chromatography. The construction of a pressurized wide and flat column (100 mm x 100 mm x 1 mm) operated under an inlet pressure of up to 50 bar was described previously. However, to become a modern analytical method, simultaneous 2D-LC requires the development of detectors suitable for the monitoring of the composition of the eluent of this pressurized planar, wide column. An array of five equidistant micro-electrochemical sensors was built for this purpose and tested. Each sensor is a three-electrode system, with the working electrode being a 25 microm polished platinum micro-electrode. The auxiliary electrode is a thin platinum wire and the reference electrode an Ag/AgCl (3M sat. KCl) electrode. In this first implementation, proof of principle is demonstrated, but the final instrument will require a much larger array. 2010 Elsevier B.V. All rights reserved.

  17. Evaluation of two membrane-based microextraction techniques for the determination of endocrine disruptors in aqueous samples by HPLC with diode array detection.

    Science.gov (United States)

    Luiz Oenning, Anderson; Lopes, Daniela; Neves Dias, Adriana; Merib, Josias; Carasek, Eduardo

    2017-11-01

    In this study, the viability of two membrane-based microextraction techniques for the determination of endocrine disruptors by high-performance liquid chromatography with diode array detection was evaluated: hollow fiber microporous membrane liquid-liquid extraction and hollow-fiber-supported dispersive liquid-liquid microextraction. The extraction efficiencies obtained for methylparaben, ethylparaben, bisphenol A, benzophenone, and 2-ethylhexyl-4-methoxycinnamate from aqueous matrices obtained using both approaches were compared and showed that hollow fiber microporous membrane liquid-liquid extraction exhibited higher extraction efficiency for most of the compounds studied. Therefore, a detailed optimization of the extraction procedure was carried out with this technique. The optimization of the extraction conditions and liquid desorption were performed by univariate analysis. The optimal conditions for the method were supported liquid membrane with 1-octanol for 10 s, sample pH 7, addition of 15% w/v of NaCl, extraction time of 30 min, and liquid desorption in 150 μL of acetonitrile/methanol (50:50 v/v) for 5 min. The linear correlation coefficients were higher than 0.9936. The limits of detection were 0.5-4.6 μg/L and the limits of quantification were 2-16 μg/L. The analyte relative recoveries were 67-116%, and the relative standard deviations were less than 15.5%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Rapid pretreatment and determination of bisphenol A in water samples based on vortex-assisted liquid-liquid microextraction followed by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Yang, Xiao; Diao, Chun-Peng; Sun, Ai-Ling; Liu, Ren-Min

    2014-10-01

    A method for the rapid pretreatment and determination of bisphenol A in water samples based on vortex-assisted liquid-liquid microextraction followed by high-performance liquid chromatography with fluorescence detection was proposed in this paper. A simple apparatus consisting of a test tube and a cut-glass dropper was designed and applied to collect the floating extraction drop in liquid-liquid microextraction when low-density organic solvent was used as the extraction solvent. Solidification and melting steps that were tedious but necessary once the low-density organic solvent used as extraction solvent could be avoided by using this apparatus. Bisphenol A was selected as model pollutant and vortex-assisted liquid-liquid microextraction was employed to investigate the usefulness of the apparatus. High-performance liquid chromatography with fluorescence detection was selected as the analytical tool for the detection of bisphenol A. The linear dynamic range was from 0.10 to 100 μg/L for bisphenol A, with good squared regression coefficient (r(2) = 0.9990). The relative standard deviation (n = 7) was 4.7% and the limit of detection was 0.02 μg/L. The proposed method had been applied to the determination of bisphenol A in natural water samples and was shown to be economical, fast, and convenient. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Determination of chlorophenols in honey samples using in-situ ionic liquid-dispersive liquid-liquid microextraction as a pretreatment method followed by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Chen; Li, Nai; Cao, Xueli

    2015-05-01

    In-situ ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) method was developed as a pretreatment method for the detection of six chlorophenols (CPs) in honey samples. The hydrophobic ionic liquid [C4MIM][NTf2], formed in-situ by the hydrophilic ionic liquid [C4MIM][BF4] and the ion exchange reagent LiNTf2 was used as the microextractant solvent of CPs from honey sample. Then the enriched analytes were back-extracted into 40 μL of 0.14 M NaOH solution and finally subjected to analysis by high-performance liquid chromatography. The method showed low limit of detection of CPs, 0.8-3.2 μg/L and high enrichment factor, 34-65 with the recoveries range from 91.60% to 114.33%. The method is simple, rapid, environmentally friendly and with high extraction efficiency. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. High-performance liquid chromatography-mass spectrometry-based acetylcholinesterase assay for the screening of inhibitors in natural extracts

    NARCIS (Netherlands)

    de Jong, C.F.; Derks, R.J.E.; Bruyneel, B.; Niessen, W.M.A.; Irth, H.

    2006-01-01

    The present paper describes a High-performance liquid chromatography-mass spectrometry (LC-MS) methodology for the screening of acetylcholinesterase (AChE) inhibitors in natural extracts. AChE activity of sample components is monitored by a post-column biochemical assay that is based on the

  1. Simultaneous determination of phenolic compounds and saponins in quinoa (Chenopodium quinoa Willd) by a liquid chromatography-diode array detection-electrospray ionization-time-of-flight mass spectrometry methodology.

    Science.gov (United States)

    Gómez-Caravaca, Ana María; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto; Caboni, Maria Fiorenza

    2011-10-26

    A new liquid chromatography methodology coupled to a diode array detector and a time-of-flight mass spectrometer has been developed for the simultaneous determination of phenolic compounds and saponins in quinoa (Chenopodium quinoa Willd). This method has allowed the simultaneous determination of these two families of compounds with the same analytical method for the first time. A fused-core column C18 has been used, and the analysis has been performed in less than 27 min. Both chromatographic and electrospray ionization time-of-flight mass spectrometry parameters have been optimized to improve the sensitivity and to maximize the number of compounds detected. A validation of the method has also been carried out, and free and bound polar fractions of quinoa have been studied. Twenty-five compounds have been tentatively identified and quantified in the free polar fraction, while five compounds have been tentatively identified and quantified in the bound polar fraction. It is important to highlight that 1-O-galloyl-β-D-glucoside, acacetin, protocatechuic acid 4-O-glucoside, penstebioside, ethyl-m-digallate, (epi)-gallocatechin, and canthoside have been tentatively identified for the first time in quinoa. Free phenolic compounds have been found to be in the range of 2.746-3.803 g/kg of quinoa, while bound phenolic compounds were present in a concentration that varies from 0.139 and 0.164 g/kg. Indeed, saponins have been found to be in a concentration that ranged from 5.6 to 7.5% of the total composition of whole quinoa flour.

  2. Separation of four flavonol glycosides from Solanum rostratum Dunal using aqueous two-phase flotation followed by preparative high-performance liquid chromatography.

    Science.gov (United States)

    Chang, Lin; Shao, Qian; Xi, Xingjun; Chu, Qiao; Wei, Yun

    2017-02-01

    Aqueous two-phase flotation followed by preparative high-performance liquid chromatography was used to separate four flavonol glycosides from Solanum rostratum Dunal. In the aqueous two-phase flotation section, the effects of sublation solvent, solution pH, (NH 4 ) 2 SO 4 concentration in aqueous solution, cosolvent, N 2 flow rate, flotation time, and volumes of the polyethylene glycol phase on the recovery were investigated in detail, and the optimal conditions were selected: 50 wt% polyethylene glycol 1000 ethanol solvent as the flotation solvent, pH 4, 350 g/L of (NH 4 ) 2 SO 4 concentration in aqueous phase, 40 mL/min of N 2 flow rate, 30 min of flotation time, 10.0 mL of flotation solvent volume, and two times. After aqueous two-phase flotation concentration, the flotation products were purified by preparative high-performance liquid chromatography. The purities of the final products A and B were 98.1 and 99.0%. Product B was the mixture of three compounds based on the analysis of high-performance liquid chromatography at the temperature of 10°C, while product A was hyperoside after the identification by nuclear magnetic resonance. Astragalin, 3'-O-methylquercetin 3-O-β-d-galactopyranoside, and 3'-O-methylquercetin 3-O-β-d-glucopyranoside were obtained with the purity of 93.8, 97.1, and 99.2%, respectively, after the further separation of product B using preparative high-performance liquid chromatography. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Highly sensitive assay for tyrosine hydroxylase activity by high-performance liquid chromatography.

    Science.gov (United States)

    Nagatsu, T; Oka, K; Kato, T

    1979-07-21

    A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.

  4. Assessment of strobilurin fungicides' content in soya-based drinks by liquid micro-extraction and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Campillo, Natalia; Iniesta, María Jesús; Viñas, Pilar; Hernández-Córdoba, Manuel

    2015-01-01

    Seven strobilurin fungicides were pre-concentrated from soya-based drinks using dispersive liquid-liquid micro-extraction (DLLME) with a prior protein precipitation step in acid medium. The enriched phase was analysed by liquid chromatography (LC) with dual detection, using diode array detection (DAD) and electrospray-ion trap tandem mass spectrometry (ESI-IT-MS/MS). After selecting 1-undecanol and methanol as the extractant and disperser solvents, respectively, for DLLME, the Taguchi experimental method, an orthogonal array design, was applied to select the optimal solvent volumes and salt concentration in the aqueous phase. The matrix effect was evaluated and quantification was carried out using external aqueous calibration for DAD and matrix-matched calibration method for MS/MS. Detection limits in the 4-130 and 0.8-4.5 ng g(-1) ranges were obtained for DAD and MS/MS, respectively. The DLLME-LC-DAD-MS method was applied to the analysis of 10 different samples, none of which was found to contain residues of the studied fungicides.

  5. EXTRACTION AND QUANTITATIVE ANALYSIS OF ELEMENTAL SULFUR FROM SULFIDE MINERAL SURFACES BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY. (R826189)

    Science.gov (United States)

    A simple method for the quantitative determination of elemental sulfur on oxidized sulfide minerals is described. Extraction of elemental sulfur in perchloroethylene and subsequent analysis with high-performance liquid chromatography were used to ascertain the total elemental ...

  6. High performance liquid chromatography analysis of aliphatic thiols in alimentary supplements and pharmaceuticals using menadione as a new useful derivatization reagent.

    Science.gov (United States)

    Gatti, Rita; Vitellaro, Valeria

    2013-12-04

    The use of menadione (MD) as a pre-column reagent for high performance liquid chromatography (HPLC) analysis of aliphatic thiols is proposed. The reaction was carried out for 5 min at room temperature and pH 8.5. The developed method was applied to the N-acetylcysteine (NAC) analysis of alimentary supplements and pharmaceutical formulations. The effect of the complex matrix was evaluated by the study of the thiol derivatization reaction both in standard and in placebo solutions. The yield of NAC-MD adduct was found to be quantitative at a reagent to thiol molar ratio of about 4 in comparison with an authentic specimen of synthesized NAC adduct, which was characterized by (1)H NMR, IR and UV. The routine chromatographic separations were performed on a Synergi MAX-RP column using a mobile phase consisting of methanol/triethylammonium (TEA) phosphate buffer (pH 3; 0.05 mol L(-1)) 70:30 (v/v) at a flow-rate of 0.4 mL min(-1). UV-diode array detection was used setting the wavelength at λ=260 nm. The validation parameters such as linearity, sensitivity, accuracy, precision, selectivity and ruggedness were found to be highly satisfactory. Similar linear responses were observed by standard and placebo solutions (determination coefficient: 0.9996). Limit of detection was about 0.019 μg g(-1). Intra-day precision (relative standard deviation, R.S.D.) was ≤0.81% for NAC to internal standard (IS) peak area ratio, ≤0.28% and ≤0.32%, respectively, for NAC and IS retention times (tR), without significant differences between intra- and inter-day data. NAC recovery studies gave good results (100.12%) with R.S.D.=1.05%. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Multi-component determination and chemometric analysis of Paris polyphylla by ultra high performance liquid chromatography with photodiode array detection.

    Science.gov (United States)

    Chen, Pei; Jin, Hong-Yu; Sun, Lei; Ma, Shuang-Cheng

    2016-09-01

    Multi-source analysis of traditional Chinese medicine is key to ensuring its safety and efficacy. Compared with traditional experimental differentiation, chemometric analysis is a simpler strategy to identify traditional Chinese medicines. Multi-component analysis plays an increasingly vital role in the quality control of traditional Chinese medicines. A novel strategy, based on chemometric analysis and quantitative analysis of multiple components, was proposed to easily and effectively control the quality of traditional Chinese medicines such as Chonglou. Ultra high performance liquid chromatography was more convenient and efficient. Five species of Chonglou were distinguished by chemometric analysis and nine saponins, including Chonglou saponins I, II, V, VI, VII, D, and H, as well as dioscin and gracillin, were determined in 18 min. The method is feasible and credible, and enables to improve quality control of traditional Chinese medicines and natural products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Ultrahigh performance supercritical fluid chromatography of lipophilic compounds with application to synthetic and commercial biodiesel.

    Science.gov (United States)

    Ashraf-Khorassani, M; Yang, J; Rainville, P; Jones, M D; Fountain, K J; Isaac, G; Taylor, L T

    2015-03-01

    Ultrahigh performance supercritical fluid chromatography (UHPSFC) in combination with sub-2μm particles and either diode array ultraviolet (UV), evaporative light scattering, (ELSD), or mass spectrometric (MS) detection has been shown to be a valuable technique for the determination of acylglycerols in soybean, corn, sesame, and tobacco seed oils. Excellent resolution on an un-endcapped single C18 column (3.0mm×150mm) with a mobile phase gradient of acetonitrile and carbon dioxide in as little as 10min served greatly as an improvement on first generation packed column SFC instrumentation. Unlike high resolution gas chromatography and high performance liquid chromatography with mass spectrometric detection, UHPSFC/MS was determined to be a superior analytical tool for both separation and detection of mono-, di-, and tri-acylglycerols as well as free glycerol itself in biodiesel without derivatization. Baseline separation of residual tri-, di-, and mono-acylglycerols alongside glycerol at 0.05% (w/w) was easily obtained employing packed column SFC. The new analytical methodology was applied to both commercial B100 biodiesel (i.e. fatty acid methyl esters) derived from vegetable oil and to an "in-house" synthetic biodiesel (i.e. fatty acid ethyl esters) derived from tobacco seed oil and ethanol both before and after purification via column chromatography on bare silica. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. High-throughput, Highly Sensitive Analyses of Bacterial Morphogenesis Using Ultra Performance Liquid Chromatography*

    Science.gov (United States)

    Desmarais, Samantha M.; Tropini, Carolina; Miguel, Amanda; Cava, Felipe; Monds, Russell D.; de Pedro, Miguel A.; Huang, Kerwyn Casey

    2015-01-01

    The bacterial cell wall is a network of glycan strands cross-linked by short peptides (peptidoglycan); it is responsible for the mechanical integrity of the cell and shape determination. Liquid chromatography can be used to measure the abundance of the muropeptide subunits composing the cell wall. Characteristics such as the degree of cross-linking and average glycan strand length are known to vary across species. However, a systematic comparison among strains of a given species has yet to be undertaken, making it difficult to assess the origins of variability in peptidoglycan composition. We present a protocol for muropeptide analysis using ultra performance liquid chromatography (UPLC) and demonstrate that UPLC achieves resolution comparable with that of HPLC while requiring orders of magnitude less injection volume and a fraction of the elution time. We also developed a software platform to automate the identification and quantification of chromatographic peaks, which we demonstrate has improved accuracy relative to other software. This combined experimental and computational methodology revealed that peptidoglycan composition was approximately maintained across strains from three Gram-negative species despite taxonomical and morphological differences. Peptidoglycan composition and density were maintained after we systematically altered cell size in Escherichia coli using the antibiotic A22, indicating that cell shape is largely decoupled from the biochemistry of peptidoglycan synthesis. High-throughput, sensitive UPLC combined with our automated software for chromatographic analysis will accelerate the discovery of peptidoglycan composition and the molecular mechanisms of cell wall structure determination. PMID:26468288

  10. Ultra-high performance liquid chromatography coupled with photo-diode array and quadrupole/time-of-flight mass spectrometry based chemical profiling approach to evaluate the influence of preparation methods on the holistic quality of Qiong-Yu-Gao, a traditional complex herbal medicine.

    Science.gov (United States)

    Xu, Jin-Di; Mao, Qian; Shen, Hong; Zhu, Ling-Ying; Li, Song-Lin; Yan, Ru

    2013-08-23

    Qiong-Yu-Gao (QYG), consisting of Rehmanniae Radix (RR), Poriae (PO) and Ginseng Radix (GR), is a commonly used tonic traditional complex herbal medicine (CHM). So far, three different methods have been documented for preparation of QYG, i.e. method 1 (M1): mixing powders of GR and PO with decoction of RR; method 2 (M2): combining the decoction of RR and PO with the decoction of GR; method 3 (M3): decocting the mixture of RR, GR and PO. In present study, an ultra-high performance liquid chromatography coupled with photo-diode array and quadrupole/time-of-flight mass spectrometry (UHPLC-PDA-QTOF-MS/MS) based chemical profiling approach was developed to investigate the influence of the three preparation methods on the holistic quality of QYG. All detected peaks were unambiguously identified by comparing UV spectra, accurate mass data/characteristic mass fragments and retention times with those of reference compounds, and/or tentatively assigned by matching empirical molecular formula with that of known compounds, and/or elucidating quasi-molecular ions and fragment ions referring to information available in literature. A total of 103 components, mainly belonging to ginsenosides, phenethylalcohol glycosides, iridoid glycosides and triterpenoid acids, were identified, of which 5 degraded ginsenosides were putatively determined to be newly generated during preparation procedures of QYG samples. Triterpenoid acids and malonyl-ginsenosides were detected only in M1 samples, while degraded ginsenosides were merely detectable in M2/M3 samples. The possible reasons for the difference among chemical profiles of QYG samples prepared with three methods were also discussed. It could be concluded that preparation method do significantly affect the holistic quality of QYG. The influence of the altered chemical profiles on the bioactivity of QYG needs further investigation. The present study demonstrated that UHPLC-PDA-QTOF-MS/MS based chemical profiling approach is efficient and

  11. Preparation and quantification of the total phenolic products in Citrus fruit using solid-phase extraction coupled with high-performance liquid chromatography with diode array and UV detection.

    Science.gov (United States)

    Zeng, Honglian; Liu, Zhenli; Zhao, Siyu; Shu, Yisong; Song, Zhiqian; Wang, Chun; Dong, Yunzhuo; Ning, Zhangchi; He, Dan; Wang, Menglei; Lu, Cheng; Liu, Yuanyan; Lu, Aiping

    2016-10-01

    Citrus fruit is an important health-promoting food that is rich in dietary phenolic metabolites. Traditional Chinese medicines, such as Zhishi and Zhiqiao, come from young and immature fruits of Citrus cultivars. The preparation of diversified bioactive phenolic products and establishment of the corresponding quality control methodology are challenging and necessary. In the current study, four types of solid-phase extraction sorbents for the enrichment and clean-up of the phenolic matrix were evaluated. A solid-phase extraction column coated with Strata-X was finally used in the procedure. Twenty phenolic compounds were selected to evaluate the extraction performances of the sorbents using high-performance liquid chromatography analysis. Under the optimized conditions, good linearities were obtained with R 2 more than 0.9996 for all analytes with LODs of 0.04-1.012 μg/g. Intra- and interday relative standard deviation values were less than 3%, and the recovery was equal to or higher than 90.02%. Compared to non-solid-phase extraction process, the content of total phenolic products was elevated 35.55-68.48% with solid-phase extraction. Finally, the developed and validated method was successfully applied to the discrimination of Zhishi samples from different species as well as Zhishi and Zhiqiao samples in different development stages. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Quantification of glibenclamide in cleaning samples of pharmaceutical equipment through high performance liquid chromatography

    International Nuclear Information System (INIS)

    Baeza Fonte, Alen Nils; Diaz Aguila, Elsa Eneida; Martinez Alfonso; Nancy

    2012-01-01

    to submit a selective analytical method for quantization of glibenclamide in cleaning samples of pharmaceutical equipment using high performance liquid chromatography. The mobile phase consisted of an equal mixing of acetonitrile/phosphate buffer KH 2 PO 4 ; with 0.037 mol/L concentration pH 5.25 and flow of 1.5 mL/min, in a Nucleosil 100 C8 column. Glibenclamide was injected with progesterone as internal standard and using an UV detector= 230 nm

  13. High performance liquid chromatographic determination of ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-08

    ) high performance liquid chromatography (HPLC) grade .... applications. These are important requirements if the reagent is to be applicable to on-line pre or post column derivatisation in a possible automation of the analytical.

  14. 21 CFR 862.2260 - High pressure liquid chromatography system for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false High pressure liquid chromatography system for... Clinical Laboratory Instruments § 862.2260 High pressure liquid chromatography system for clinical use. (a) Identification. A high pressure liquid chromatography system for clinical use is a device intended to separate...

  15. Denaturing high-performance liquid chromatography mutation analysis in patients with reduced Protein S levels

    DEFF Research Database (Denmark)

    Bathum, Lise; Münster, Anna-Marie; Nybo, Mads

    2008-01-01

    diagnosis and risk estimation. The aim was to design a high-throughput genetic analysis based on denaturing high-performance liquid chromatography to identify sequence variations in the gene coding for Protein S. PATIENTS: In total, 55 patients referred to the Section of Thrombosis and Haemostasis, Odense......BACKGROUND: Patients with congenital Protein S deficiency have increased risk of venous thromboembolism. However, Protein S levels show large intra-individual variation and the biochemical assays have low accuracy and a high interlaboratory variability. Genetic analysis might aid in a more precise......, giving a precise diagnosis and subsequently a better risk estimation....

  16. Validation of a high-performance liquid chromatography/fluorescence detection method for the simultaneous quantification of fifteen polycyclic aromatic hydrocarbons

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Olsen, I L; Holst, E

    1991-01-01

    A high-performance liquid chromatography/fluorescence method using multiple wavelength shift for simultaneous quantification of different PAH compounds was developed. The new method was superior to the methods of DONG and GREENBERG [J. Liquid Chromatogr. 11, 1887-1905 (1988)] and WISE et al...... that no systematic errors, and only small unsystematic errors, could be demonstrated. Furthermore, the method had a good reproducibility and a high sensitivity....

  17. High Performance Liquid Chromatography Determination of Urinary Hippuric Acid and Benzoic Acid as Indices for Glue Sniffer Urine

    OpenAIRE

    Abdul Rahim Yacob; Mohamad Raizul Zinalibdin

    2010-01-01

    A simple method for the simultaneous determination of hippuric acid and benzoic acid in urine using reversed-phase high performance liquid chromatography was described. Chromatography was performed on a Nova-Pak C18 (3.9 x 150 mm) column with a mobile phase of mixed solution methanol: water: acetic acid (20:80:0.2) and UV detection at 254 nm. The calibration curve was linear within concentration range at 0.125 to 6.0 mg/ml of hippuric acid and benzoic acid. The recovery, ...

  18. Screening of Norharmane from Seven Cyanobacteria by High-performance Liquid Chromatography.

    Science.gov (United States)

    Karan, Tunay; Erenler, Ramazan

    2017-10-01

    Cyanobacteria, including pharmaceutically and medicinally valuable compounds attract the great attention lately. Norharmane (9H-pyrido (3,4-b) indole found in some cyanobacteria revealed a great number of biological effects. Seven cyanobacteria were isolated and identified from Yesilirmak River and Gaziosmanpasa University Campus to determine the norharmane content. Cyanobacteria collected from Tokat, Turkey were isolated and identified by morphologically. Norharmane (9H-pyrido [3,4-b] indole) quantities were presented for seven cyanobacteria, Chroococcus minutus (Kütz.) Nägeli, Geitlerinema carotinosum (Geitler) Anagnostidis, Nostoc linckia Bornet ex Bornet and Flahault, Anabaena oryzae F. E. Fritsch, Oscillatoria limnetica Lemmermann, Phormidium sp . Kützing ex Gomont, and Cylindrospermum sp . Kutzing ex E. Bornet and C. Flahault by high-performance liquid chromatography. The norharmane amount indicated for cyanobacterial culture media altered in a species-dependent kind in the range of 0.81-10.87 μg/g. C. minutus produced the most norharmane among the investigated cyanobacteria as 10.87 μg/g. Cyanobacteria could be an important source of norharmane as well as pharmaceutically valuable compounds. Seven cyanobacteria were isolated and identified from Yesilirmak RiverQuantitative analysis of norharmane was executed on isolated cyanobacteriaFour cyanobecteria species included the norharmane Chroococcus minutus contained the most norharmane (10.87 μg/g). Abbreviations used: HPLC: High performance liquid chromatograph.

  19. Screening of Norharmane from Seven Cyanobacteria by High-performance Liquid Chromatography

    Science.gov (United States)

    Karan, Tunay; Erenler, Ramazan

    2017-01-01

    Background: Cyanobacteria, including pharmaceutically and medicinally valuable compounds attract the great attention lately. Norharmane (9H-pyrido (3,4-b) indole found in some cyanobacteria revealed a great number of biological effects. Objective: Seven cyanobacteria were isolated and identified from Yesilirmak River and Gaziosmanpasa University Campus to determine the norharmane content. Materials and Methods: Cyanobacteria collected from Tokat, Turkey were isolated and identified by morphologically. Norharmane (9H-pyrido [3,4-b] indole) quantities were presented for seven cyanobacteria, Chroococcus minutus (Kütz.) Nägeli, Geitlerinema carotinosum (Geitler) Anagnostidis, Nostoc linckia Bornet ex Bornet and Flahault, Anabaena oryzae F. E. Fritsch, Oscillatoria limnetica Lemmermann, Phormidium sp. Kützing ex Gomont, and Cylindrospermum sp. Kutzing ex E. Bornet and C. Flahault by high-performance liquid chromatography. Results: The norharmane amount indicated for cyanobacterial culture media altered in a species-dependent kind in the range of 0.81–10.87 μg/g. C. minutus produced the most norharmane among the investigated cyanobacteria as 10.87 μg/g. Conclusion: Cyanobacteria could be an important source of norharmane as well as pharmaceutically valuable compounds. SUMMARY Seven cyanobacteria were isolated and identified from Yesilirmak RiverQuantitative analysis of norharmane was executed on isolated cyanobacteriaFour cyanobecteria species included the norharmaneChroococcus minutus contained the most norharmane (10.87 μg/g). Abbreviations used: HPLC: High performance liquid chromatograph. PMID:29142439

  20. Development and validation of a rapid high performance liquid chromatography - photodiode array detection method for estimation of a bioactive compound wedelolactone in extracts of Eclipta alba

    Directory of Open Access Journals (Sweden)

    Satyanshu Kumar

    2013-03-01

    Full Text Available Following optimization of extraction, separation and analytical conditions, a rapid, sensitive and simple reverse-phase high performance liquid chromatography-photo diode array (HPLC-PDA method has been developed for the identification and quantification of wedelolactone in different extracts of Eclipta alba. The separation of wedelolactone was achieved on a C18 column using the solvent system consisting of a mixture of methanol: water: acetic acid (95: 5: 0.04 as a mobile phase in isocratic elution mode followed by photo diode array detection at 352 nm. The developed method was validated as per the guidelines of the International Conference on Harmonization (ICH. Calibration curve presented good linear regression (r²>0.998 within the test range and the maximum relative standard deviation (RSD, % values for intra-day assay were found to be 0.15, 1.30 and 1.1 for low (5 µg/mL, medium (20 µg/mL and high (80 µg/mL concentrations of wedelolactone. For inter-day assay the maximum RSD (% values were found to be 2.83, 1.51 and 2.06 for low, medium and high concentrations, respectively. Limit of detection (LOD and limit of quantification (LOQ were calculated to be 2 and 5 µg/mL respectively. Analytical recovery of wedelolactone was greater than 95%. Wedelolactone in different extracts of Eclipta alba was identified and quantified using the developed HPLC method. The validated HPLC method allowed precise quantitative analysis of wedelolactone in Eclipta. alba extracts.Desenvolveu-se método rápido, sensível e simples de Cromatografia Líquida de Alta Eficiência em fase reversa, utilizando-se arranjo de fotodiodo (HPLC-PDA, visando à separação, extração e às condições analíticas para a identificação e quantificação de wedelolactona em diferentes extratos de Eclipta alba. A separação de wedelolactona foi efetuada por meio de uma coluna C18, utilizando mistura de metanol:água:ácido acético (95:5:0.04 como fase móvel, em sistema de

  1. Simultaneous determination of iridoid glycosides, phenethylalcohol glycosides and furfural derivatives in Rehmanniae Radix by high performance liquid chromatography coupled with triple-quadrupole mass spectrometry

    DEFF Research Database (Denmark)

    Xu, Jun; Wu, Jie; Zhu, Ling-Ying

    2012-01-01

    In this study, a sensitive and selective method for simultaneously quantifying eight major components (four iridoid glycosides, three phenethylalcohol glycosides and one furfural derivative) of Rehmanniae Radix by high performance liquid chromatography coupled with triple-quadrupole mass spectrom......In this study, a sensitive and selective method for simultaneously quantifying eight major components (four iridoid glycosides, three phenethylalcohol glycosides and one furfural derivative) of Rehmanniae Radix by high performance liquid chromatography coupled with triple-quadrupole mass...

  2. A High Power InGaN-Based Blue-Violet Laser Diode Array with a Broad-Area Stripe

    International Nuclear Information System (INIS)

    Chen Ping; Zhao De-Gang; Feng Mei-Xin; Jiang De-Sheng; Liu Zong-Shun; Yang Hui; Zhang Li-Qun; Li De-Yao; Liu Jian-Ping; Wang Hui; Zhu Jian-Jun; Zhang Shu-Ming; Zhang Bao-Shun

    2013-01-01

    An array of high power InGaN/GaN multi-quantum-well laser diodes with a broad waveguide is fabricated. The laser diode structure is grown on a GaN substrate by metal-organic chemical vapor deposition. The laser diode array consists of five emitter stripes which share common electrodes on one laser chip. The electrical and optical characteristics of the laser diode array are investigated under the pulse current injection with 10kHz frequency and 100 ns pulse width. The laser diode array emits at the wavelength of 409 nm, which is located in the blue-violet region, and the threshold current is 2.9 A. The maximum output light peak power is measured to be 7.5 W at the wavelength of 411.8 nm under the current of 25 A

  3. A simple high performance liquid chromatography method for analyzing paraquat in soil solution samples.

    Science.gov (United States)

    Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter

    2004-01-01

    A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.

  4. Analyses of Indole Compounds in Sugar Cane (Saccharum officinarum L. Juice by High Performance Liquid Chromatography and Liquid Chromatography-Mass Spectrometry after Solid-Phase Extraction

    Directory of Open Access Journals (Sweden)

    Jean Wan Hong Yong

    2017-03-01

    Full Text Available Simultaneous quantitative analysis of 10 indole compounds, including indole-3-acetic acid (IAA, one of the most important naturally occurring auxins and some of its metabolites, by high performance liquid chromatography (HPLC and liquid chromatography-mass spectrometry (LC-MS after solid-phase extraction (SPE was reported for the first time. The analysis was carried out using a reverse phase HPLC gradient elution, with an aqueous mobile phase (containing 0.1% formic acid modified by methanol. Furthermore, a novel SPE procedure was developed for the pre-concentration and purification of indole compounds using C18 SPE cartridges. The combination of SPE, HPLC, and LC-MS was applied to screen for the indole compounds present in sugar cane (Saccharum officinarum L. juice, a refreshing beverage with various health benefits. Finally, four indole compounds were successfully detected and quantified in sugar cane juice by HPLC, which were further unequivocally confirmed by LC-MS/MS experiments operating in the multiple reaction monitoring (MRM mode.

  5. Analysis of aqueous humour in uveitis by high performance liquid chromatography and sodium dodecyl sulphate-polyacrylamide gel electrophoresis

    NARCIS (Netherlands)

    Murray, P. I.; Hoekzema, R.; Luyendijk, L.; Kijlstra, A.

    1992-01-01

    Aqueous humour from patients with Fuchs' heterochromic cyclitis (FHC) and other types of uveitis was analysed by high performance liquid chromatography (HPLC) and sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE). Using HPLC, the number of peaks and their respective elution times

  6. Simultaneous Determination of Caffeine and Vitamin B6 in Energy Drinks by High-Performance Liquid Chromatography (HPLC)

    Science.gov (United States)

    Leacock, Rachel E.; Stankus, John J.; Davis, Julian M.

    2011-01-01

    A high-performance liquid chromatography experiment to determine the concentration of caffeine and vitamin B6 in sports energy drinks has been developed. This laboratory activity, which is appropriate for an upper-level instrumental analysis course, illustrates the standard addition method and simultaneous determination of two species. (Contains 1…

  7. A simple, rapid and validated high-performance liquid chromatography method suitable for clinical measurements of human mercaptalbumin and non-mercaptalbumin.

    Science.gov (United States)

    Yasukawa, Keiko; Shimosawa, Tatsuo; Okubo, Shigeo; Yatomi, Yutaka

    2018-01-01

    Background Human mercaptalbumin and human non-mercaptalbumin have been reported as markers for various pathological conditions, such as kidney and liver diseases. These markers play important roles in redox regulations throughout the body. Despite the recognition of these markers in various pathophysiologic conditions, the measurements of human mercaptalbumin and non-mercaptalbumin have not been popular because of the technical complexity and long measurement time of conventional methods. Methods Based on previous reports, we explored the optimal analytical conditions for a high-performance liquid chromatography method using an anion-exchange column packed with a hydrophilic polyvinyl alcohol gel. The method was then validated using performance tests as well as measurements of various patients' serum samples. Results We successfully established a reliable high-performance liquid chromatography method with an analytical time of only 12 min per test. The repeatability (within-day variability) and reproducibility (day-to-day variability) were 0.30% and 0.27% (CV), respectively. A very good correlation was obtained with the results of the conventional method. Conclusions A practical method for the clinical measurement of human mercaptalbumin and non-mercaptalbumin was established. This high-performance liquid chromatography method is expected to be a powerful tool enabling the expansion of clinical usefulness and ensuring the elucidation of the roles of albumin in redox reactions throughout the human body.

  8. Ultra-high performance supercritical fluid chromatography of lignin-derived phenols from alkaline cupric oxide oxidation.

    Science.gov (United States)

    Sun, Mingzhe; Lidén, Gunnar; Sandahl, Margareta; Turner, Charlotta

    2016-08-01

    Traditional chromatographic methods for the analysis of lignin-derived phenolic compounds in environmental samples are generally time consuming. In this work, an ultra-high performance supercritical fluid chromatography method with a diode array detector for the analysis of major lignin-derived phenolic compounds produced by alkaline cupric oxide oxidation was developed. In an analysis of a collection of 11 representative monomeric lignin phenolic compounds, all compounds were clearly separated within 6 min with excellent peak shapes, with a limit of detection of 0.5-2.5 μM, a limit of quantification of 2.5-5.0 μM, and a dynamic range of 5.0-2.0 mM (R(2) > 0.997). The new ultra-high performance supercritical fluid chromatography method was also applied for the qualitative and quantitative analysis of lignin-derived phenolic compounds obtained upon alkaline cupric oxide oxidation of a commercial humic acid. Ten out of the previous eleven model compounds could be quantified in the oxidized humic acid sample. The high separation power and short analysis time obtained demonstrate for the first time that supercritical fluid chromatography is a fast and reliable technique for the analysis of lignin-derived phenols in complex environmental samples. © 2016 The Authors, Journal of Separation Science Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. UHPLC: The Greening Face of Liquid Chromatography

    OpenAIRE

    Cielecka-Piontek, Judyta; Zalewski, Przemys?aw; Jeli?ska, Anna; Garbacki, Piotr

    2013-01-01

    Pharmaceutical analysis based on chromatographic separation is an important part of studies aimed at developing routine quality analysis of drugs. High-performance liquid chromatography (HPLC) is one of the main analytical techniques recommended for drug analysis. Although it meets many criteria vital for analysis, it is time-consuming and uses a relatively high amount of organic solvents compared to other analytical techniques. Recently, Ultra-high-performance liquid chromatography (UHPLC) h...

  10. Core-shell in liquid chromatography: application for determining sulphonamides in feed and meat using conventional chromatographic systems

    Directory of Open Access Journals (Sweden)

    Antonio Armentano

    2016-12-01

    Full Text Available A C18 column packed with core-shell particles was used for the chromatographic separation of sulphonamides in feed and meat by a conventional high performance liquid chromatography system coupled with a diode array detector. Two analytical methods, already used in our laboratory, have been modified without any changes in the extraction and clean-up steps and in the liquid chromatography instrumentation. Chromatographic conditions applied on a traditional 5-μm column have been optimized on a column packed with 2.6 μm core-shell particles. A binary mobile phase [acetate buffer solution at pH 4.50 and a mixture of methanol acetonitrile 50: 50 (v/v] was employed in gradient mode at the flow rate of 1.2 mL with an injection volume of 6 μL. These chromatographic conditions allow the separation of 13 sulphonamides with an entire run of 13 minutes. Preliminary studies have been carried out comparing blanks and spiked samples of feed and meat. A good resolution and the absence of interferences were achieved in chromatograms for both matrices. Since no change was made to the sample preparation, the optimized method does not require a complete revalidation and can be used to make routine analysis faster.

  11. High Performance Liquid Chromatography of Vitamin A: A Quantitative Determination.

    Science.gov (United States)

    Bohman, Ove; And Others

    1982-01-01

    Experimental procedures are provided for the quantitative determination of Vitamin A (retinol) in food products by analytical liquid chromatography. Standard addition and calibration curve extraction methods are outlined. (SK)

  12. Validated High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, rapid and sensitive high performance liquid ... response, tailing factor and resolution of six replicate injections was < 3 %. ... Cefadroxil monohydrate, Human plasma, Pharmacokinetics Bioequivalence ... Drug-free plasma was obtained from the local .... Influence of probenicid on the renal.

  13. An Efficient Protocol for Preparation of Gallic Acid from Terminalia bellirica (Gaertn.) Roxb by Combination of Macroporous Resin and Preparative High-Performance Liquid Chromatography.

    Science.gov (United States)

    Zou, Denglang; Chen, Tao; Chen, Chen; Li, Hongmei; Liu, Yongling; Li, Yulin

    2016-08-01

    In this article, macroporous resin column chromatography and preparative high-performance liquid chromatography were applied for preparation of gallic acid from Terminalia bellirica (Gaertn.) Roxb. In the first step, six kinds of resins were investigated by adsorption and desorption tests and AB-8 macroporous resin was selected for the enrichment of gallic acid. As a result, 20 g of gallic acid at a purity of 71% could be separated from 100 g of crude extract in which the content of gallic acid was 16.7% and the recovery of gallic acid reached 85.0%. In the second step, preparative high-performance liquid chromatography was selected to purify gallic acid. As a result, 640 mg of gallic acid at a purity of 99.1% was obtained from 1 g of sample in 35 min. The results demonstrated that macroporous resin coupled with preparative high-performance liquid chromatography was suitable for preparation of gallic acid from T. bellirica (Gaertn.) Roxb. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Analysis of residual products in benzyl chloride used for the industrial synthesis of quaternary compounds by liquid chromatography with diode-array detection.

    Science.gov (United States)

    Prieto-Blanco, M C; López-Mahía, P; Prada-Rodríguez, D

    2009-02-01

    In industrial and pharmaceutical processes, the study of residual products becomes essential to guarantee the quality of compounds and to eliminate or minimize toxic residual products. Knowledge about the origin of impurities (raw materials, processes, the contamination of industrial plants, etc.) is necessary in preventive treatment and in the control of a product's lifecycle. Benzyl chloride is used as raw material to synthesize several quaternary ammonium compounds, such as benzalkonium chloride, which may have pharmaceutical applications. Benzaldehyde, benzyl alcohol, toluene, chloro derivatives of toluene, and dibenzyl ether are compounds that may be found as impurities in technical benzyl chloride. We proposed a high-performance liquid chromatography method for the separation of these compounds, testing two stationary phases with different dimensions and particle sizes, with the application of photodiode array-detection. The linearity for four possible impurities (benzaldehyde, toluene, alpha,alpha-dichlorotoluene, and 2-chlorotoluene) ranged from 0.1 to 10 microg/mL, limits of detection from 11 to 34 ng/mL, and repeatability from 1% to 2.9% for a 0.3-1.2 microg/mL concentration range. The method was applied to samples of technical benzyl chloride, and alpha,alpha-dichlorotoluene and benzaldehyde were identified by spectral analysis and quantitated. The selection of benzyl chloride with lower levels of impurities is important to guarantee the reduction of residual products in further syntheses.

  15. The Determination of Polyethylene Glycol in Untreated Urine Samples by High Performance Liquid Chromatography for Intestinal Permeability Studies

    DEFF Research Database (Denmark)

    Larsen, Elfinn; Pedersen, Walther Batsberg; Philipsen, E.

    1985-01-01

    Polyethylene glycol in urine samples has been investigated by high performance liquid chromatography. The molecular weights ranged from 634 to 1338. The urine samples were applied to the chromatographic system without any pre-treatment. For samples with a concentration of 0.2% polyethylene glycol...

  16. Ultra Performance Liquid Chromatography Tandem Mass ...

    African Journals Online (AJOL)

    NICOLAAS

    drugs alone.16. After a single oral dose of 120–800 mg of NTB in healthy sub- jects in a fasting state the peak plasma NTB concentration (tmax) was found to be 4–7 h, with a half-life of approximately 9–17 h.17 ... performance liquid chromatography mass spectrometry/mass .... to the likely biological plasma constituents.

  17. High-performance liquid chromatography for determination of α-tocopherol in vegetables

    Directory of Open Access Journals (Sweden)

    Marcin Horbowicz

    2013-12-01

    Full Text Available A simple method for the determination of α-tocopherol in vegetables is described. The procedure consists of the following steps: saponification, extraction, silica-column clean-up, and high-performance liquid chromatography. Elution time for D, L-α-tocopherol was 9.0 min using a Zorbax Sil (250 x 4.6 mm column and an isocratic mobile phase of hexane-methanol (99.3 + 0.7, with a flow rate of 1 ml/min, and detection at 292 nm using a variable UV detector. The average recovery of α-tocopherol was 91.2%, and the minimum detectable amount was 0.1 mg/100 g of fresh vegetable tissue. This method is comparable to gas-chromatographic determination of α-tocopherol, but has fewer analytical steps and gives more reproducible results.

  18. RECENT ADVANCES IN ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FOR THE ANALYSIS OF TRADITIONAL CHINESE MEDICINE

    Science.gov (United States)

    Huang, Huilian; Liu, Min; Chen, Pei

    2014-01-01

    Traditional Chinese medicine has been widely used for the prevention and treatment of various diseases for thousands of years in China. Ultra-high performance liquid chromatography (UHPLC) is a relatively new technique offering new possibilities. This paper reviews recent developments in UHPLC in the separation and identification, fingerprinting, quantification, and metabolism of traditional Chinese medicine. Recently, the combination of UHPLC with MS has improved the efficiency of the analysis of these materials. PMID:25045170

  19. Burn-up measurements on nuclear reactor fuels using high performance liquid chromatography

    International Nuclear Information System (INIS)

    Sivaraman, N.; Subramaniam, S.; Srinivasan, T.G.; Vasudeva Rao, P.R.

    2002-01-01

    Burn-up measurements on thermal as well as fast reactor fuels were carried out using high performance liquid chromatography (HPLC). A column chromatographic technique using di-(2-ethylhexyl) phosphoric acid (HDEHP) coated column was employed for the isolation of lanthanides from uranium, plutonium and other fission products. Ion-pair HPLC was used for the separation of individual lanthanides. The atom percent fissions were calculated from the concentrations of the lanthanide (neodymium in the case of thermal reactor and lanthanum for the fast reactor fuels) and from uranium and plutonium contents of the dissolver solutions. The HPLC method was also used for determining the fractional fissions from uranium and plutonium for the thermal reactor fuel. (author)

  20. Characterization of phenolic amides from cortex lycii by ultra high-performance liquid chromatography coupled with LTQ-Orbitrap mass spectrometry

    Science.gov (United States)

    High performance liquid chromatography (UPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The...

  1. Analysis by high-performance liquid chromatography of teucrin A in beverages flavoured with an extract of Teucrium chamaedrys L.

    Science.gov (United States)

    Bosisio, E; Giavarini, F; Dell'Agli, M; Galli, G; Galli, C L

    2004-05-01

    Due to its liver toxicity, the medicinal use of germander (Teucrium chamaedrys L.) was banned in some countries. Nevertheless, alcoholic extracts are still permitted as flavour ingredients since they are fundamental in providing a bitter aromatic taste. Teucrin A represents the substance of major concern regarding the potential toxicity of germander. Hence, teucrin A represents the best analytical and toxicological marker of alcoholic extracts of T. chamaedrys. A sensitive high-performance liquid chromatography method to detect teucrin A in beverages is reported. Teucrin A was prepared by isolation from the plant extract using column chromatography and crystallization. The identity and purity (99%) were established by melting point, nuclear magnetic resonance and liquid chromatography-mass spectrometry. The high-performance liquid chromatography procedure was validated and its intra- and interday performance was established (relative standard deviation beverages not containing T. chamaedrys spiked with a range of concentrations of teucrin A. The limit of detection was 0.1 ppm and the limit of quantification was 0.3 ppm. Teucrin A accounted for about 70% of the neo-clerodane diterpenoids found in the total extract of a specimen of T. chamaedrys. The content (+/- standard deviation) in 18 batches of different geographical origin was 2338 +/- 740 ppm, per cent coefficient of variation = 32, minimum-maximum = 999 - 3445 ppm. The mean level of teucrin A in 10 bottles of the same brand was 6.1 +/- 0.8 ppm, per cent coefficient of variation = 12. In 10 different brands found on the Italian market, the content of teucrin A ranged from not detectable to 10 ppm.

  2. Determination of Polycyclic Aromatic Hydrocarbons in Automobile Exhaust by Means of High-Performance Liquid Chromatography with Fluorescence Detection

    DEFF Research Database (Denmark)

    Nielsen, Tom

    1979-01-01

    A chromatographic method has been developed and applied to the determination of polycyclic aromatic hydrocarbons (PAHs) in particulate matter in automobile exhaust, in petrols, and in crankcase oils. The PAHs were purified from other organic compounds by thin-layer chromatography, separated by high......-performance liquid chromatography, and measured by means of on-line fluorescence detection. The identities of the PAHs were verified by comparing the emission spectra obtained by a stop-flow technique with those of standard PAHs...

  3. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    Science.gov (United States)

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  4. Application of dispersive liquid-liquid microextraction for the preconcentration of eight parabens in real samples and their determination by high-performance liquid chromatography.

    Science.gov (United States)

    Shen, Xiong; Liang, Jian; Zheng, Luxia; Lv, Qianzhou; Wang, Hong

    2017-11-01

    A simple and sensitive method for the simultaneous determination of eight parabens in human plasma and urine samples was developed. The samples were preconcentrated using dispersive liquid-liquid microextraction based on the solidification of floating organic drops and determined by high-performance liquid chromatography with ultraviolet detection. The influence of variables affecting the extraction efficiency was investigated and optimized using Placket-Burman design and Box-Behnken design. The optimized values were: 58 μL of 1-decanol (as extraction solvent), 0.65 mL methanol (as disperser solvent), 1.5% w/v NaCl in 5.0 mL of sample solution, pH 10.6, and 4.0 min centrifugation at 4000 rpm. The extract was injected into the high-performance liquid chromatography system for analysis. Under the optimum conditions, the linear ranges for eight parabens in plasma and urine were 1.0-1000 ng/mL, with correlation coefficients above 0.994. The limit of detection was 0.2-0.4 and 0.1-0.4 ng/mL for plasma and urine samples, respectively. Relative recoveries were between 80.3 and 110.7%, while relative standard deviations were less than 5.4%. Finally, the method was applied to analyze the parabens in 98 patients of primary breast cancer. Results showed that parabens existed widely, at least one paraben detected in 96.9% (95/98) of plasma samples and 98.0% (96/98) of urine samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Highly Sensitive Determination of 2,4,6-Trinitrotoluene and Related Byproducts Using a Diol Functionalized Column for High Performance Liquid Chromatography

    NARCIS (Netherlands)

    Gümüscü, B.; Erdogan, Zeynep; Guler, Mustafa O.; Tekinay, Turgay

    2016-01-01

    In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has

  6. Determination of diacylhydrazines-type insect growth regulator JS-118 residues in cabbage and soil by high performance liquid chromatography with DAD detection.

    Science.gov (United States)

    Hu, J-Y; Deng, Z-B; Qin, D-M

    2009-12-01

    JS-118 is a diacylhydrazines-type insect growth regulator used extensively in China now. An analytical method for residues determination of JS-118 in cabbage and soil samples by high performance liquid chromatography with DAD detection was established and optimized. Primary secondary amine solid phase extraction cartridge was used for sample preparation. Mean recoveries for the analyte ranged from 96.6% to 107.0% with CV value less than 4.7%. The limit of quantification is 0.01 mg/kg. Direct confirmation of JS-118 residues in samples was realized by high performance liquid chromatography-mass spectrometry. The proposed method is simple, rapid and reliable to perform and could be utilized for monitoring of pesticides residues.

  7. Determination of dasatinib in the tablet dosage form by ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis.

    Science.gov (United States)

    Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel

    2017-01-01

    Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Separation and Quantitation of Polyamines in Plant Tissue by High Performance Liquid Chromatography of Their Dansyl Derivatives

    Science.gov (United States)

    Smith, Mary A.; Davies, Peter J.

    1985-01-01

    High performance liquid chromatography in combination with fluorescence spectrophotometry can be used to separate and quantitate polyamines (putrescine, cadaverine, spermidine, spermine), prepared as their dansyl derivatives, from plant tissue. The procedure gives sensitive and consistent results for polyamine determinations in plant tissue. In a standard mixture, the minimal detection level was less than 1 picomole of polyamines. PMID:16664216

  9. Low Density Solvent-Based Dispersive Liquid-Liquid Microextraction for the Determination of Synthetic Antioxidants in Beverages by High-Performance Liquid Chromatography

    Science.gov (United States)

    Çabuk, Hasan; Köktürk, Mustafa

    2013-01-01

    A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL−1. The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries. PMID:23853535

  10. Low Density Solvent-Based Dispersive Liquid-Liquid Microextraction for the Determination of Synthetic Antioxidants in Beverages by High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Hasan Çabuk

    2013-01-01

    Full Text Available A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL−1. The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries.

  11. [Qualitative and quantitative analysis of amygdalin and its metabolite prunasin in plasma by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry].

    Science.gov (United States)

    Gao, Meng; Wang, Yuesheng; Wei, Huizhen; Ouyang, Hui; He, Mingzhen; Zeng, Lianqing; Shen, Fengyun; Guo, Qiang; Rao, Yi

    2014-06-01

    A method was developed for the determination of amygdalin and its metabolite prunasin in rat plasma after intragastric administration of Maxing shigan decoction. The analytes were identified by ultra-high performance liquid chromatography-tandem quadrupole time of flight mass spectrometry and quantitatively determined by ultra-high performance liquid chromatography-tandem triple quadrupole mass spectrometry. After purified by liquid-liquid extraction, the qualitative analysis of amygdalin and prunasin in the plasma sample was performed on a Shim-pack XR-ODS III HPLC column (75 mm x 2.0 mm, 1.6 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on a Triple TOF 5600 quadrupole time of flight mass spectrometer. The quantitative analysis of amygdalin and prunasin in the plasma sample was performed by separation on an Agilent C18 HPLC column (50 mm x 2.1 mm, 1.7 microm), using acetonitrile-0.1% (v/v) formic acid aqueous solution. The detection was performed on an AB Q-TRAP 4500 triple quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operated in negative ion mode and multiple-reaction monitoring (MRM) mode. The qualitative analysis results showed that amygdalin and its metabolite prunasin were detected in the plasma sample. The quantitative analysis results showed that the linear range of amygdalin was 1.05-4 200 ng/mL with the correlation coefficient of 0.999 0 and the linear range of prunasin was 1.25-2 490 ng/mL with the correlation coefficient of 0.997 0. The method had a good precision with the relative standard deviations (RSDs) lower than 9.20% and the overall recoveries varied from 82.33% to 95.25%. The limits of detection (LODs) of amygdalin and prunasin were 0.50 ng/mL. With good reproducibility, the method is simple, fast and effective for the qualitative and quantitative analysis of the amygdalin and prunasin in plasma sample of rats which were administered by Maxing shigan decoction.

  12. Quantification of sulphur amino acids by ultra-high performance liquid chromatography in aquatic invertebrates.

    Science.gov (United States)

    Thera, Jennifer C; Kidd, Karen A; Dodge-Lynch, M Elaine; Bertolo, Robert F

    2017-12-15

    We examined the performance of an ultra-high performance liquid chromatography method to quantify protein-bound sulphur amino acids in zooplankton. Both cysteic acid and methionine sulfone were linear from 5 to 250 pmol (r 2  = 0.99), with a method detection limit of 13 pmol and 9 pmol, respectively. Although there was no matrix effect on linearity, adjacent peaks and co-eluting noise from the invertebrate proteins increased the detection limits when compared to common standards. Overall, performance characteristics were reproducible and accurate, and provide a means for quantifying sulphur amino acids in aquatic invertebrates, an understudied group. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Progress report on the use of hybrid silicon pin diode arrays in high energy physics

    International Nuclear Information System (INIS)

    Shapiro, S.L.; Jernigan, J.G.; Arens, J.F.

    1990-05-01

    We report on the successful effort to develop hybrid PIN diode arrays and to demonstrate their potential as components of vertex detectors. Hybrid pixel arrays have been fabricated by the Hughes Aircraft Co. by bump-bonding readout chips developed by Hughes to an array of PIN diodes manufactured by Micron Semiconductor Inc. These hybrid pixel arrays were constructed in two configurations. One array format has 10 x 64 pixels, each 120 μm square; and the other format has 256 x 156 pixels, each 30 μm square. In both cases, the thickness of the PIN diode layer is 300 μm. Measurements of detector performance show that excellent position resolution can be achieved by interpolation. By determining the centroid of the charge cloud which spreads charge into a number of neighboring pixels, a spatial resolution of a few microns has been attained. The noise has been measured to be about 300 electrons (rms) at room temperature, as expected from KTC and dark current considerations, yielding a signal-to-noise ratio of about 100 for minimum ionizing particles. 4 refs., 17 figs

  14. Quantitative determination of acetaminophen, phenylephrine and carbinoxamine in tablets by high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Carina de A. Bastos

    2009-01-01

    Full Text Available An alternative methodology for analysis of acetaminophen (Ace, phenylephrine (Phe and carbinoxamine (Car in tablets by ion-pair reversed phase high performance liquid chromatography was validated. The pharmaceutical preparations were analyzed by using a C18 column (5 μm, 300 mm, 3.9 mm and mobile phase consisting of 60% methanol and 40% potassium monobasic phosphate aqueous solution (62.46 mmol L-1 added with 1 mL phosphoric acid, 0.50 mL triethylamine and 0.25 g sodium lauryl sulfate. Isocratic analysis was performed under direct UV detection at 220 nm for Phe and Car and at 300 nm for Ace within 5 min.

  15. Diode lasers and arrays

    International Nuclear Information System (INIS)

    Streifer, W.

    1988-01-01

    This paper discusses the principles of operation of III-V semiconductor diode lasers, the use of distributed feedback, and high power laser arrays. The semiconductor laser is a robust, miniature, versatile device, which directly converts electricity to light with very high efficiency. Applications to pumping solid-state lasers and to fiber optic and point-to-point communications are reviewed

  16. Determination of citrus limonoid glucosides by high performance liquid chromatography coupled to post-column reaction with Ehrlich’s Reagent

    Science.gov (United States)

    A method for the identification and quantification of citrus limonoid glucosides in juices based upon high performance liquid chromatography (HPLC) separation coupled to post-column reaction with Ehrlichs’s reagent has been developed. This method utilizes a phenyl stationary phase and an isocratic ...

  17. Standardization of heparins by means of high performance liquid chromatography equipped with a low angle laser light scattering detector

    NARCIS (Netherlands)

    Hennink, W.E.; van den Berg, J.W.A.; Feijen, Jan

    1987-01-01

    This study shows that HPLC-LALLS (high performance liquid chromatography with a light-scattering detector) is a convenient and reliable method for the characterization of standard heparin samples, provided that polyelectrolyte artefacts are suppressed by a suitable dialysis procedure. The method has

  18. Analysis of native human plasma proteins and haemoglobin for the presence of bityrosine by high-performance liquid chromatography

    DEFF Research Database (Denmark)

    Daneshvar, B; Frandsen, H; Dragsted, L O

    1997-01-01

    fluorescent substance, bityrosine. High-performance liquid chromatography (HPLC) analysis of acid hydrolyzed serum albumin after oxidation with peroxidase/H2O2 or with Cu++/H2O2 showed that bityrosine had been formed whereas oxidation of this protein with Fe(III)/ascorbate did not result in the formation...

  19. Online analysis of five organic ultraviolet filters in environmental water samples using magnetism-enhanced monolith-based in-tube solid phase microextraction coupled with high-performance liquid chromatography.

    Science.gov (United States)

    Mei, Meng; Huang, Xiaojia

    2017-11-24

    Due to the endocrine disrupting properties, organic UV filters have been a great risk for humans and other organisms. Therefore, development of accurate and effective analytical methods is needed for the determination of UV filters in environmental waters. In this work, a fast, sensitive and environmentally friendly method combining magnetism-enhanced monolith-based in-tube solid phase microextraction with high-performance liquid chromatography with diode array detection (DAD) (ME-MB-IT/SPME-HPLC-DAD) for the online analysis of five organic UV filters in environmental water samples was developed. To extract UV filters effectively, an ionic liquid-based monolithic capillary column doped with magnetic nanoparticles was prepared by in-situ polymerization and used as extraction medium of online ME-MB-IT/SPME-HPLC-DAD system. Several extraction conditions including the intensity of magnetic field, sampling and desorption flow rate, volume of sample and desorption solvent, pH value and ionic strength of sample matrix were optimized thoroughly. Under the optimized conditions, the extraction efficiencies for five organic UV filters were in the range of 44.0-100%. The limits of detection (S/N=3) and limits of quantification (S/N=10) were 0.04-0.26μg/L and 0.12-0.87μg/L, respectively. The precisions indicated by relative standard deviations (RSDs) were less than 10% for both intra- and inter-day variabilities. Finally, the developed method was successfully applied to the determination of UV filters in three environmental water samples and satisfactory results were obtained. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Fast and sensitive analysis of beta blockers by ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry.

    Science.gov (United States)

    Tomková, Jana; Ondra, Peter; Kocianová, Eva; Václavík, Jan

    2017-07-01

    This paper presents a method for the determination of acebutolol, betaxolol, bisoprolol, metoprolol, nebivolol and sotalol in human serum by liquid-liquid extraction and ultra-high-performance liquid chromatography coupled with ultra-high-resolution TOF mass spectrometry. After liquid-liquid extraction, beta blockers were separated on a reverse-phase analytical column (Acclaim RS 120; 100 × 2.1 mm, 2.2 μm). The total run time was 6 min for each sample. Linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability were evaluated. The method was successfully applied to the therapeutic drug monitoring of 108 patients with hypertension. This method was also used for determination of beta blockers in 33 intoxicated patients. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Rapid determination of some psychotropic drugs in complex matrices by tandem dispersive liquid-liquid microextraction followed by high performance liquid chromatography.

    Science.gov (United States)

    Asghari, Alireza; Fahimi, Ebrahim; Bazregar, Mohammad; Rajabi, Maryam; Boutorabi, Leila

    2017-05-01

    Simple and rapid determinations of some psychotropic drugs in some pharmaceutical wastewater and human plasma samples were successfully accomplished via the tandem dispersive liquid-liquid microextraction combined with high performance liquid chromatography-ultraviolet detection (TDLLME-HPLC-UV). TDLLME of the three psychotropic drugs clozapine, chlorpromazine, and thioridazine was easily performed through two consecutive dispersive liquid-liquid microextractions. By performing this convenient method, proper sample preconcentrations and clean-ups were achieved in just about 7min. In order to achieve the best extraction efficiency, the effective parameters involved were optimized. The optimal experimental conditions consisted of 100μL of CCl 4 (as the extraction organic solvent), and the pH values of 13 and 2 for the donor and acceptor phases, respectively. Under these optimum experimental conditions, the proposed TDLLME-HPLC-UV technique provided a good linearity in the range of 5-3000ngmL -1 for the three psychotropic drugs with the correlation of determinations (R 2 s) higher than 0.996. The limits of quantification (LOQs) and limits of detection (LODs) obtained were 5.0ngmL -1 and 1.0-1.5ngmL -1 , respectively. Also the proper enrichment factors (EFs) of 96, 99, and 88 for clozapine, chlorpromazine, and thioridazine, respectively, and good extraction repeatabilities (relative standard deviations below 9.3%, n=5) were obtained. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Ionic liquid-based air-assisted liquid-liquid microextraction followed by high performance liquid chromatography for the determination of five fungicides in juice samples.

    Science.gov (United States)

    You, Xiangwei; Chen, Xiaochu; Liu, Fengmao; Hou, Fan; Li, Yiqiang

    2018-01-15

    A novel and simple ionic liquid-based air-assisted liquid-liquid microextraction technique combined with high performance liquid chromatography was developed to analyze five fungicides in juice samples. In this method, ionic liquid was used instead of a volatile organic solvent as the extraction solvent. The emulsion was formed by pulling in and pushing out the mixture of aqueous sample solution and extraction solvent repeatedly using a 10mL glass syringe. No organic dispersive solvent was required. Under the optimized conditions, the limits of detection (LODs) were 0.4-1.8μgL -1 at a signal-to-noise ratio of 3. The limits of quantification (LOQs) set as the lowest spiking levels with acceptable recovery in juices were 10μgL -1 , except for fludioxonil whose LOQ was 20μgL -1 . The proposed method was applied to determine the target fungicides in juice samples, and acceptable recoveries ranging from 74.9% to 115.4% were achieved. Copyright © 2017. Published by Elsevier Ltd.

  3. High perfomance liquid chromatography fingerprint analysis for quality control of brotowali (Tinospora crispa)

    Science.gov (United States)

    Syarifah, V. B.; Rafi, M.; Wahyuni, W. T.

    2017-05-01

    Brotowali (Tinospora crispa) is widely used in Indonesia as ingredient of herbal medicine formulation. To ensure the quality, safety, and efficacy of herbal medicine products, its chemical constituents should be continuously evaluated. High performance liquid chromatography (HPLC) fingerprint is one of powerful technique for this quality control process. In this study, HPLC fingerprint analysis method was developed for quality control of brotowali. HPLC analysis was performed in C18 column and detection was performed using photodiode array detector. The optimum mobile phase for brotowali fingerprint was acetonitrile (ACN) and 0.1% formic acid in gradient elution mode at a flow rate of 1 mL/min. The number of peaks detected in HPLC fingerprint of brotowali was 32 peaks and 23 peaks for stems and leaves, respectively. Berberine as marker compound was detected at retention time of 20.525 minutes. Evaluation of analytical performance including precision, reproducibility, and stability prove that this HPLC fingerprint analysis was reliable and could be applied for quality control of brotowali.

  4. Pre-concentration of uranium from water samples by dispersive liquid-liquid micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Khajeh, Mostafa; Nemch, Tabandeh Karimi [Zabol Univ. (Iran, Islamic Republic of). Dept. of Chemistry

    2014-07-01

    In this study, a simple and rapid dispersive liquid-liquid microextraction (DLLME) was developed for the determination of uranium in water samples prior to high performance liquid chromatography with diode array detection. 1-(2-pyridylazo)-2-naphthol (PAN) was used as complexing agent. The effect of various parameters on the extraction step including type and volume of extraction and dispersive solvents, pH of solution, concentration of PAN, extraction time, sample volume and ionic strength were studied and optimized. Under the optimum conditions, the limit of detection (LOD) and preconcentration factor were 0.3 μg L{sup -1} and 194, respectively. Furthermore, the relative standard deviation of the ten replicate was <2.6%. The developed procedure was then applied to the extraction and determination of uranium in the water samples.

  5. Pre-concentration of uranium from water samples by dispersive liquid-liquid micro-extraction

    International Nuclear Information System (INIS)

    Khajeh, Mostafa; Nemch, Tabandeh Karimi

    2014-01-01

    In this study, a simple and rapid dispersive liquid-liquid microextraction (DLLME) was developed for the determination of uranium in water samples prior to high performance liquid chromatography with diode array detection. 1-(2-pyridylazo)-2-naphthol (PAN) was used as complexing agent. The effect of various parameters on the extraction step including type and volume of extraction and dispersive solvents, pH of solution, concentration of PAN, extraction time, sample volume and ionic strength were studied and optimized. Under the optimum conditions, the limit of detection (LOD) and preconcentration factor were 0.3 μg L -1 and 194, respectively. Furthermore, the relative standard deviation of the ten replicate was <2.6%. The developed procedure was then applied to the extraction and determination of uranium in the water samples.

  6. Separation of three anthraquinone glycosides including two isomers by preparative high-performance liquid chromatography and high-speed countercurrent chromatography from Rheum tanguticum Maxim. ex Balf.

    Science.gov (United States)

    Chen, Tao; Li, Hongmei; Zou, Denglang; Liu, Yongling; Chen, Chen; Zhou, Guoying; Li, Yulin

    2016-08-01

    Anthraquinone glycosides, such as chrysophanol 1-O-β-d-glucoside, chrysophanol 8-O-β-d-glucoside, and physion 8-O-β-d-glucoside, are the accepted important active components of Rheum tanguticum Maxim. ex Balf. due to their pharmacological properties: antifungal, antimicrobial, cytotoxic, and antioxidant activities. However, an effective method for the separation of the above-mentioned anthraquinone glycosides from this herb is not currently available. Especially, greater difficulty existed in the separation of the two isomers chrysophanol 1-O-β-d-glucoside and chrysophanol 8-O-β-d-glucoside. This study demonstrated an efficient strategy based on preparative high-performance liquid chromatography and high-speed countercurrent chromatography for the separation of the above-mentioned anthraquinone glycosides from Rheum tanguticum Maxim.ex Balf. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Crosslinked polymeric ionic liquids as solid-phase microextraction sorbent coatings for high performance liquid chromatography.

    Science.gov (United States)

    Yu, Honglian; Merib, Josias; Anderson, Jared L

    2016-03-18

    Neat crosslinked polymeric ionic liquid (PIL) sorbent coatings for solid-phase microextraction (SPME) compatible with high-performance liquid chromatography (HPLC) are reported for the first time. Six structurally different PILs were crosslinked to nitinol supports and applied for the determination of select pharmaceutical drugs, phenolics, and insecticides. Sampling conditions including sample solution pH, extraction time, desorption solvent, desorption time, and desorption solvent volume were optimized using design of experiment (DOE). The developed PIL sorbent coatings were stable when performing extractions under acidic pH and remained intact in various organic desorption solvents (i.e., methanol, acetonitrile, acetone). The PIL-based sorbent coating polymerized from the IL monomer 1-vinyl-3-(10-hydroxydecyl) imidazolium chloride [VC10OHIM][Cl] and IL crosslinker 1,12-di(3-vinylbenzylimidazolium) dodecane dichloride [(VBIM)2C12] 2[Cl] exhibited superior extraction performance compared to the other studied PILs. The extraction efficiency of pharmaceutical drugs and phenolics increased when the film thickness of the PIL-based sorbent coating was increased while many insecticides were largely unaffected. Satisfactory analytical performance was obtained with limits of detection (LODs) ranging from 0.2 to 2 μg L(-1) for the target analytes. The accuracy of the analytical method was examined by studying the relative recovery of analytes in real water samples, including tap water and lake water, with recoveries varying from 50.2% to 115.9% and from 48.8% to 116.6%, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Simultaneous determination of furfural and its degradation products, furoic acid and maleic acid, in transformer oil by the reversed-phase vortex-assisted liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Yifan; Li, Haiyan; Yang, Zhen; Zhang, Weijie; Hua, Jia

    2017-12-01

    To explore why the use of furfural as a transformer oil-paper insulation aging characteristic is problematic in real world application, we developed a method for the simultaneous determination of furfural, furoic acid, and maleic acid in transformer oil by reversed-phase vortex-assisted liquid-liquid microextraction combined with high-performance liquid chromatography. The conditions for the proposed method were optimized, and the obtained extract can be directly analyzed by high-performance liquid chromatography. The detection limits (signal-to-noise ratio = 3) of the method ranged from 1.0 to 4.6 μg/L, the enrichment factors for furfural, furoic acid, maleic acid, and fumaric acid were 4.6, 25.1, 15.6, and 17.5, respectively, and the recovery rates for three analytes (fumaric acid was undetected) range from 82.1 to 106.2%. The contents of furfural, furoic acid, and maleic acid resulted from accelerated aging of transformer insulation oil-paper were measured using the present method for the first time, and the aging samples were analyzed by liquid chromatography with mass spectrometry for the identification of furoic acid and maleic acid in the aging transformer oil samples. Using the optimal method, the target products of samples at different aging time were tracked and measured. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Quantitative and pattern recognition analysis of five marker compounds in Raphani semen using high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Jung, Yeon Woo; Lee, Joo Sang; Zhao, Bing Tian; Woo, Mi Hee; Min, Byung Sun; Kim, Jeong Ah; Eun, Rhan Woo

    2015-01-01

    A rapid and simple high-performance liquid chromatography (HPLC)-photodiode array (PDA) analytical method was developed for the quantitative analysis of Raphani Semen (RS). This method was successfully used to determine the five main phenolic compounds found in RS specimens from different production regions. The compounds included sinapine thiocyanate (1), β-d-fructofuranosyl-α-d-(6-O-sinapoyl)-glucopyranoside (2), isorhamnetin 3,4′-di-O-β-d-glucoside (3), β-d-(3-O-sinapoyl)-fructofuranosyl-α-d-(6-O-sinapoyl)-glucopyranoside (4), and β-d-(3,4-O-disinapoyl)-fructofuranosyl-α-d-(6-O-sinapoyl)-glucopyranoside (5). The marker compounds were separated using an Agilent Eclipse XDB-C18 column (5.0 µm, 150 × 4.6 mm i.d.) by gradient elution with acetonitrile/water/0.1% trifluoroacetic acid (TFA) as the mobile phase (flow rate, 1.0 mL/min). This method was fully validated with respect to linearity, precision, accuracy, stability, and robustness. The HPLC analytical method was validated to conduct a pattern recognition analysis by repeatedly analyzing 56 seed samples including 55 RS (C01–C49 and K50–K55) and 1 Brassicae Semen samples. In addition, a content standard for RS was proposed. Compounds 1 and 4 were revealed as major components in the HPLC chromatogram, and their contents ranged from 0.06 to 0.20 and 0.02 to 0.35 mg/g, respectively. These results demonstrate the successful development of an analytical method suitable for evaluating the quality and distinguishing the origin of RS. In addition, we briefly describe the crucial liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical conditions for the precise simultaneous quantification of the marker compounds

  10. Quantitative and pattern recognition analysis of five marker compounds in Raphani semen using high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yeon Woo; Lee, Joo Sang; Zhao, Bing Tian; Woo, Mi Hee; Min, Byung Sun [College of Pharmacy, Drug Research and Development Center, Catholic University of Daegu, Gyeongsan (Korea, Republic of); Kim, Jeong Ah [College of Pharmacy, Research Institute of Pharmaceutical Sciences, Kyungpook National University, Daegu (Korea, Republic of); Eun, Rhan Woo [College of Pharmacy, Chosun University, Gwangju (Korea, Republic of)

    2015-09-15

    A rapid and simple high-performance liquid chromatography (HPLC)-photodiode array (PDA) analytical method was developed for the quantitative analysis of Raphani Semen (RS). This method was successfully used to determine the five main phenolic compounds found in RS specimens from different production regions. The compounds included sinapine thiocyanate (1), β-d-fructofuranosyl-α-d-(6-O-sinapoyl)-glucopyranoside (2), isorhamnetin 3,4′-di-O-β-d-glucoside (3), β-d-(3-O-sinapoyl)-fructofuranosyl-α-d-(6-O-sinapoyl)-glucopyranoside (4), and β-d-(3,4-O-disinapoyl)-fructofuranosyl-α-d-(6-O-sinapoyl)-glucopyranoside (5). The marker compounds were separated using an Agilent Eclipse XDB-C18 column (5.0 µm, 150 × 4.6 mm i.d.) by gradient elution with acetonitrile/water/0.1% trifluoroacetic acid (TFA) as the mobile phase (flow rate, 1.0 mL/min). This method was fully validated with respect to linearity, precision, accuracy, stability, and robustness. The HPLC analytical method was validated to conduct a pattern recognition analysis by repeatedly analyzing 56 seed samples including 55 RS (C01–C49 and K50–K55) and 1 Brassicae Semen samples. In addition, a content standard for RS was proposed. Compounds 1 and 4 were revealed as major components in the HPLC chromatogram, and their contents ranged from 0.06 to 0.20 and 0.02 to 0.35 mg/g, respectively. These results demonstrate the successful development of an analytical method suitable for evaluating the quality and distinguishing the origin of RS. In addition, we briefly describe the crucial liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical conditions for the precise simultaneous quantification of the marker compounds.

  11. Sensitivity enhancement by chromatographic peak concentration with ultra-high performance liquid chromatography-nuclear magnetic resonance spectroscopy for minor impurity analysis.

    Science.gov (United States)

    Tokunaga, Takashi; Akagi, Ken-Ichi; Okamoto, Masahiko

    2017-07-28

    High performance liquid chromatography can be coupled with nuclear magnetic resonance (NMR) spectroscopy to give a powerful analytical method known as liquid chromatography-nuclear magnetic resonance (LC-NMR) spectroscopy, which can be used to determine the chemical structures of the components of complex mixtures. However, intrinsic limitations in the sensitivity of NMR spectroscopy have restricted the scope of this procedure, and resolving these limitations remains a critical problem for analysis. In this study, we coupled ultra-high performance liquid chromatography (UHPLC) with NMR to give a simple and versatile analytical method with higher sensitivity than conventional LC-NMR. UHPLC separation enabled the concentration of individual peaks to give a volume similar to that of the NMR flow cell, thereby maximizing the sensitivity to the theoretical upper limit. The UHPLC concentration of compound peaks present at typical impurity levels (5.0-13.1 nmol) in a mixture led to at most three-fold increase in the signal-to-noise ratio compared with LC-NMR. Furthermore, we demonstrated the use of UHPLC-NMR for obtaining structural information of a minor impurity in a reaction mixture in actual laboratory-scale development of a synthetic process. Using UHPLC-NMR, the experimental run times for chromatography and NMR were greatly reduced compared with LC-NMR. UHPLC-NMR successfully overcomes the difficulties associated with analyses of minor components in a complex mixture by LC-NMR, which are problematic even when an ultra-high field magnet and cryogenic probe are used. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Haemoglobin variants may cause significant differences in haemoglobin A1c as measured by high-performance liquid chromatography and enzymatic methods in diabetic patients: a cross-sectional study.

    Science.gov (United States)

    Otabe, Shuichi; Nakayama, Hitomi; Ohki, Tsuyoshi; Soejima, Eri; Tajiri, Yuji; Yamada, Kentaro

    2017-07-01

    Background We aimed to determine whether the discrepancy between haemoglobin A1c values determined by high-performance liquid chromatography and enzymatic haemoglobin A1c measurements in diabetic patients was clinically relevant. Methods We randomly recruited 1421 outpatients undergoing diabetic treatment and follow-up who underwent at least three haemoglobin A1c measurements between April 2014 and March 2015 at our clinic. In 6369 samples, haemoglobin A1c was simultaneously measured by HA-8160 and MetaboLead (enzymatic assay), and the values were compared. Results haemoglobin A1c measurements by high-performance liquid chromatography and enzymatic assay were strongly correlated (correlation coefficient: 0.9828, linear approximation curve y = 0.9986x - 0.2507). Mean haemoglobin A1c (6.8 ± 1.0%) measured by high-performance liquid chromatography was significantly higher than that measured by enzymatic assay (6.5 ± 1.0%, P liquid chromatography than those from enzymatic assay. Of these, three had Hb Toranomon [β112 (G14) Cys→Trp]. The fourth had Hb Ube-2 [α68 (E17) Asn→Asp]. One other subject presented consistently higher haemoglobin A1c values (>1%) by high-performance liquid chromatography than those from enzymatic assay and was diagnosed with a -77 (T > C) mutation in the δ-globin gene. These unrelated asymptomatic subjects had normal erythrocyte profiles, without anaemia. Conclusions We showed that haemoglobin A1c values measured by high-performance liquid chromatography were significantly higher than those measured by enzymatic assay in diabetic subjects. However, when an oversized deviation (>0.7%) between glycaemic control status and haemoglobin A1c is apparent, clinicians should check the methods used to measure haemoglobin A1c and consider the possible presence of a haemoglobin variant.

  13. Measurement of food flavonoids by high-performance liquid chromatography: A review.

    Science.gov (United States)

    Merken, H M; Beecher, G R

    2000-03-01

    The flavonoids are plant polyphenols found frequently in fruits, vegetables, and grains. Divided into several subclasses, they include the anthocyanidins, pigments chiefly responsible for the red and blue colors in fruits, fruit juices, wines, and flowers; the catechins, concentrated in tea; the flavanones and flavanone glycosides, found in citrus and honey; and the flavones, flavonols, and flavonol glycosides, found in tea, fruits, vegetables, and honey. Known for their hydrogen-donating antioxidant activity as well as their ability to complex divalent transition metal cations, flavonoids are propitious to human health. Computer-controlled high-performance liquid chromatography (HPLC) has become the analytical method of choice. Many systems have been developed for the detection and quantification of flavonoids across one, two, or three subclasses. A summary of the various HPLC and sample preparation methods that have been employed to quantify individual flavonoids within a subclass or across several subclasses are tabulated in this review.

  14. On the use of ionic liquids as mobile phase additives in high-performance liquid chromatography. A review.

    Science.gov (United States)

    García-Alvarez-Coque, M C; Ruiz-Angel, M J; Berthod, A; Carda-Broch, S

    2015-07-09

    The popularity of ionic liquids (ILs) has grown during the last decades in several analytical separation techniques. Consequently, the number of reports devoted to the applications of ILs is still increasing. This review is focused on the use of ILs (mainly imidazolium-based associated to chloride and tetrafluoroborate) as mobile phase additives in high-performance liquid chromatography (HPLC). In this approach, ILs just function as salts, but keep several kinds of intermolecular interactions, which are useful for chromatographic separations. Both cation and anion can be adsorbed on the stationary phase, creating a bilayer. This gives rise to hydrophobic, electrostatic and other specific interactions with the stationary phase and solutes, which modify the retention behaviour and peak shape. This review updates the advances in this field, with emphasis on topics not always deeply considered in the literature, such as the mechanisms of retention, the estimation of the suppressing potency of silanols, modelling and optimisation of the chromatographic performance, and the comparison with other additives traditionally used to avoid the silanol problem. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Large-area high-power VCSEL pump arrays optimized for high-energy lasers

    Science.gov (United States)

    Wang, Chad; Geske, Jonathan; Garrett, Henry; Cardellino, Terri; Talantov, Fedor; Berdin, Glen; Millenheft, David; Renner, Daniel; Klemer, Daniel

    2012-06-01

    Practical, large-area, high-power diode pumps for one micron (Nd, Yb) as well as eye-safer wavelengths (Er, Tm, Ho) are critical to the success of any high energy diode pumped solid state laser. Diode efficiency, brightness, availability and cost will determine how realizable a fielded high energy diode pumped solid state laser will be. 2-D Vertical-Cavity Surface-Emitting Laser (VCSEL) arrays are uniquely positioned to meet these requirements because of their unique properties, such as low divergence circular output beams, reduced wavelength drift with temperature, scalability to large 2-D arrays through low-cost and high-volume semiconductor photolithographic processes, high reliability, no catastrophic optical damage failure, and radiation and vacuum operation tolerance. Data will be presented on the status of FLIR-EOC's VCSEL pump arrays. Analysis of the key aspects of electrical, thermal and mechanical design that are critical to the design of a VCSEL pump array to achieve high power efficient array performance will be presented.

  16. Determination of atenolol in human plasma using ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Zeeb, Mohsen; Farahani, Hadi; Papan, Mohammad Kazem

    2016-06-01

    An efficient analytical method called ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) to a sample solution containing an ion-pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2-750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90-96.7% and satisfactory intra-assay (4.8-5.1%, n = 6) and interassay (5.0-5.6%, n = 9) precision along with a substantial sample clean-up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Clinical value of serum bilirubin subfractionation by high-performance liquid chromatography and conventional methods in patients with primary biliary cirrhosis

    NARCIS (Netherlands)

    Jansen, P. L.; Peters, W. H.; Janssens, A. R.

    1986-01-01

    The clinical value of serum bilirubin subfractionation, using high-performance liquid chromatography (HPLC), was studied in 26 patients with primary biliary cirrhosis (PBC) from whom 59 serum samples were obtained. Total bilirubin (TB) levels were determined by alkaline methanolysis and HPLC

  18. Improved method for the determination of serotonin in plasma by high-performance liquid chromatography using on-line sample pre-treatment

    NARCIS (Netherlands)

    Takkenberg, B.; Endert, E.; van Ingen, H. E.; Ackermans, M.

    1991-01-01

    An improved method for the determination of serotonin in platelet-rich plasma (PRP) and platelet-poor plasma (PPP), by reversed-phase high-performance liquid chromatography with electrochemical detection and direct plasma injection, is described. The chromatographic system comprises a strong

  19. Separation of deuteriated isotopomers of dopamine by ion-pair reversed-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Masters, C.F.; Markey, S.P.; Mefford, I.N.; Duncan, M.W.

    1988-01-01

    The ion-pair reversed-phase separation of dopamine and deuterium-substituted dopamine isotopomers is described. Chromatographic parameters and deuterium isotope effects governing the resolution are examined and compared to the factors regulating the resolution are examined and compared to the factors regulating the resolution of the chemically distinct entities dopamine, norepinephrine, and epinephrine. The potential utility of the [ 2 H 7 ]dopamine, isotopomer as an internal standard for the high-performance liquid chromatography analysis of dopamine is demonstrated by using aluminum oxide extraction prior to chromatographic separation

  20. Plasma capric acid concentrations in healthy subjects determined by high-performance liquid chromatography.

    Science.gov (United States)

    Shrestha, Rojeet; Hui, Shu-Ping; Imai, Hiromitsu; Hashimoto, Satoru; Uemura, Naoto; Takeda, Seiji; Fuda, Hirotoshi; Suzuki, Akira; Yamaguchi, Satoshi; Hirano, Ken-Ichi; Chiba, Hitoshi

    2015-09-01

    Capric acid (FA10:0, decanoic acid) is a medium-chain fatty acid abundant in tropical oils such as coconut oil, whereas small amounts are present in milk of goat, cow, and human. Orally ingested FA10:0 is transported to the liver and quickly burnt within it. Only few reports are available for FA10:0 concentrations in human plasma. Fasting (n = 5, male/female = 3/2, age 31 ± 9.3 years old) and non-fasting (n = 106, male/female = 44/62, age 21.9 ± 3.2 years old) blood samples were collected from apparently healthy Japanese volunteers. The total FA10:0 in the plasma were measured by high-performance liquid chromatography after derivatization with 2-nitrophenylhydrazine followed by UV detection. Inter and intra-assay coefficient of variation of FA10:0 assay at three different concentrations ranged in 1.7-3.9 and 1.3-5.4%, respectively, with an analytical recovery of 95.2-104.0%. FA10:0 concentration was below detection limit (0.1 µmol/L) in each fasting human plasma. FA10:0 was not detected in 50 (47.2%) of 106 non-fasting blood samples, while 29 (27.4%) plasma samples contained FA10:0 less than or equal to 0.5 µmol/L (0.4 ± 0.1), and 27 (25.5%) contained it at more than 0.5 µmol/L (0.9 ± 0.3). A half of the non-fasting plasma samples contained detectable FA10:0. This simple, precise, and accurate high-performance liquid chromatography method might be useful for monitoring plasma FA10:0 during medium-chain triglycerides therapy. © The Author(s) 2015.

  1. Determination of interglycosidic linkages in O-glycosyl flavones by high-performance liquid chromatography/photodiode-array detection coupled to electrospray ionization ion trap mass spectrometry. Its application to Tetragonula carbonaria honey from Australia.

    Science.gov (United States)

    Truchado, Pilar; Vit, Patricia; Heard, Tim A; Tomás-Barberán, Francisco A; Ferreres, Federico

    2015-05-30

    Tetragonula carbonaria pot-honeys are highly valued as a food source and for their biological activities in Australia, and there is a growing interest to know its composition. Phenolic metabolites, which could be related to their beneficial properties, have not been studied in depth yet. Mass spectrometry (MS) coupled to liquid chromatography (LC) is an advanced technique for the study of complex flavonoids present in difficult food matrices that hampers their isolation and purification. This allows the tentative characterization of diglycosides/triglycosides establishing the position of the O-glycosylation on the sugar moiety by the study of the MS data in T. carbonaria pot-honeys from Australia. Their spectra obtained by high-performance liquid chromatography/photodiode-array detection/electrospray ionization ion trap mass spectrometry (HPLC/DAD/ESI-MS(n) ) revealed for the first time 19 quercetin, kaempferol and isorhamnetin O-glycosides. These compounds were clustered in flavonoid triglycosides, diglycosides and monoglycosides. The first cluster contained one flavonoid trihexoside, two -3-O-(2-hexosyl, 6-rhamnosyl)hexosides and their isomers and two -3-O-(2,6-di-rhamnosyl)hexosides. In the second cluster, eleven flavonoid diglycosides such as three -3-O-(2-hexosyl)hexosides, four -3-O-(2-rhamnosyl)hexosides and one -3-O-(6-rhamnosyl)hexoside as well as two -3-O-(2-pentosyl)hexosides and one tentative -3-O-(3-pentosyl)hexoside were detected. In the monoglycoside group, only one flavonoid -3-O-hexoside was identified. The occurrence of this large number of flavonoid glycosides could be due to the low glucosidase activity previously reported in stingless bee honey. Copyright © 2015 John Wiley & Sons, Ltd.

  2. Identification and quantification of flavonoids and chromes in Baeckea frutescens by using HPLC coupled with diode-array detection and quadruple time-of-flight mass spectrometry.

    Science.gov (United States)

    Jia, Bei-Xi; Huangfu, Qian-Qian; Ren, Feng-Xiao; Jia, Lu; Zhang, Yan-Bing; Liu, Hong-Min; Yang, Jie; Wang, Qiang

    2015-01-01

    This article marks the first report on high-performance liquid chromatography (HPLC) coupled with diode-array detection (DAD) and quadruple time-of-flight mass spectrometry (Q-TOF/MS) for the identification and quantification of main bioactive constituents in Baeckea frutescens. In total, 24 compounds were identified or tentatively characterised based on their retention behaviours, UV profiles and MS fragment information. Furthermore, a validated method with good linearity, sensitivity, precision, stability, repeatability and accuracy was successfully applied for simultaneous determination of five flavonoids and one chromone in different plant parts of B. frutescens collected at different harvest times, and their dynamic contents revealed the appropriate harvest times. The established HPLC-DAD-Q-TOF/MS using multi-bioactive markers was proved to be a validated strategy for the quality evaluation on both raw materials and related products of B. frutescens.

  3. Identification of glycosaminoglycans using high-performance liquid chromatography on a hydroxyapatite column.

    Science.gov (United States)

    Narita, H; Takeda, Y; Takagaki, K; Nakamura, T; Harata, S; Endo, M

    1995-11-20

    Glycosaminoglycans (heparin, heparan sulfate, dermatan sulfate, chondroitin sulfate, and hyaluronic acid) were labeled with a fluorescent reagent, 2-aminopyridine. The fluoro-labeled glycosaminoglycans were subjected to high-performance liquid chromatography on a hydroxyapatite column. The binding property of each glycosaminoglycan to hydroxyapatite was different. The structural properties of glycosaminoglycans bound to hydroxyapatite were then investigated using chemical desulfated or enzymic depolymerized glycosaminoglycans. This revealed that the sulfate content and molecular weight of the glycosaminoglycans correlated with their binding properties to hydroxyapatite. Desulfated dermatan sulfate but not desulfated chondroitin 6-sulfate bound to the hydroxyapatite. These data indicate that iduronic acid residues of glycosaminoglycans are important for the binding property. The method described which uses hydroxyapatite columns facilitates rapid separation and microanalysis of the glycosaminoglycans, especially dermatan sulfate and chondroitin sulfate.

  4. SIMULTANEOUS DETERMINATION OF PARACETAMOL AND IBUPROFENE MIXTURES BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    Directory of Open Access Journals (Sweden)

    Sophi Damayanti

    2010-06-01

    Full Text Available Analytical method for the determination of paracetamol and ibuprofene mixtures has been developed by High Performance Liquid Chromatography using C-18 column and acetinitrile - phosphate buffer pH = 4.5 (75:25 containing 0.075% sodium hexanesulfunate as a mobile phase. The detector was set at 215 nm. Using such conditions, retention time for paracetamol and ibuprofen was 4.89 and 7.11 min, respectively. The recovery for paracetamol and ibuprofen was found to be 101.07± 0.73% and 102.02 ± 1.58%, respectively. The detector limits of the method was 1.30 and 1.60 μg/mL with the relative standard deviation (RSD 0.74 and 1.52% for paracetamol and ibuprofen, respectively.   Keywords: paracetamol, ibuprofen, multi-component, validation, HPLC.

  5. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    Science.gov (United States)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  6. Discrimination of Black Ball-point Pen Inks by High Performance Liquid Chromatography (HPLC)

    International Nuclear Information System (INIS)

    Mohamed Izzharif Abdul Halim; Norashikin Saim; Rozita Osman; Halila Jasmani; Nurul Nadhirah Zainal Abidin

    2013-01-01

    In this study, thirteen types of black ball-point pen inks of three major brands were analyzed using high performance liquid chromatography (HPLC). Separation of the ink components was achieved using Bondapak C-18 column with gradient elution using water, ethanol and ethyl acetate. The chromatographic data obtained at wavelength 254.8 nm was analyzed using agglomerative hierarchical clustering (AHC) and principle component analysis (PCA). AHC was able to group the inks into three clusters. This result was supported by PCA, whereby distinct separation of the three different brands was achieved. Therefore, HPLC in combination with chemometric methods may be a valuable tool for the analysis of black ball-point pen inks for forensic purposes. (author)

  7. SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

    Energy Technology Data Exchange (ETDEWEB)

    Harpool, K; De La Fuente Herman, T; Ahmad, S; Ali, I [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and

  8. Introduction to modern liquid chromatography

    National Research Council Canada - National Science Library

    Snyder, Lloyd R; Kirkland, J. J; Dolan, John W

    2010-01-01

    "High-performance liquid chromatography (HPLC) is today the leading technique for chemical analysis and related applications, with an ability to separate, analyze, and/or purify virtually any sample...

  9. Early detection of degraded A14-125I-insulin in human fibroblasts by the use of high performance liquid chromatography

    International Nuclear Information System (INIS)

    Stentz, F.B.; Harris, H.L.; Kitabchi, A.E.

    1983-01-01

    We studied the metabolism of A14-125I-insulin in intact human fibroblasts using high performance liquid chromatography (HPLC) to detect and separate its early degradation products. The high resolving power of HPLC enabled us to separate what has been considered ''intact insulin'' by Sephadex G-50 chromatography or TCA precipitability into two additional peaks that had decreased biochemical properties with respect to immunoprecipitability and receptor binding but not decreased TCA precipitability. We conclude that human fibroblast is capable of metabolizing insulin within 2 min at 37 degrees C into intermediate molecules that can be detected by HPLC but not by TCA precipitability or molecular sieve chromatography

  10. Resolution of RNA using high-performance liquid chromatography

    NARCIS (Netherlands)

    Mclaughlin, L.W.; Bischoff, Rainer

    1987-01-01

    High-performance liquid chromatographic techniques can be very effective for the resolution and isolation of nucleic acids. The characteristic ionic (phosphodiesters) and hydrophobic (nucleobases) properties of RNAs can be exploited for their separation. In this respect anion-exchange and

  11. Quasi-CW 110 kW AlGaAs laser diode array module for inertial fusion energy laser driver

    International Nuclear Information System (INIS)

    Kawashima, Toshiyuki

    2001-01-01

    We have successfully demonstrated a large aperture 803 nm AlGaAs diode laser module as a pump source for a 1053 nm, 10 J output Nd: glass slab laser amplifier for diode-pumped solid-state laser (DPSSL) fusion driver. Detailed performance results of the laser diode module are presented, including bar package and stack configuration, and their thermal design and analysis. A sufficiently low thermal impedance of the stack was realized by combining backplane liquid cooling configuration with modular bar package architecture. Total peak power of 110 kW and electrical to optical conversion efficiently of 46% were obtained from the module consisting of a total of 1000 laser diode bars. A peak intensity of 2.6 kW/cm 2 was accomplished across an emitting area of 418 mm x 10 mm. Currently, this laser diode array module with a large two-dimensional aperture is, to our knowledge, the only operational pump source for the high output energy DPSSL. (author)

  12. A reversed-phase high-performance liquid chromatography method for the determination of cotrimoxazole (trimethoprim/ sulphamethoxazole) in children treated for malaria

    DEFF Research Database (Denmark)

    Rønn, A M; Mutabingwa, T K; Kreisby, S

    1999-01-01

    A high-performance liquid chromatography (HPLC) method was developed for the simultaneous analysis of trimethoprim (TMP), sulphamethoxazole (SMX), and acetylsulphamethoxazole (AcSMX) in small amounts of blood. The method involved precipitation with 50 microL trichloracetic acid (1M) to 125 micro...

  13. Salting-out homogenous extraction followed by ionic liquid/ionic liquid liquid-liquid micro-extraction for determination of sulfonamides in blood by high performance liquid chromatography.

    Science.gov (United States)

    Liu, Zhongling; Yu, Wei; Zhang, Hanqi; Gu, Fanbin; Jin, Xiangqun

    2016-12-01

    Salting-out homogenous extraction followed by ionic liquid/ionic liquid dispersive liquid-liquid micro-extraction system was developed and applied to the extraction of sulfonamides in blood. High-performance liquid chromatography was applied to the determination of the analytes. The blood sample was centrifuged to obtain the serum. After the proteins in the serum were removed in the presence of acetonitrile, ionic liquid 1-butyl-3-methylimidazolium tetrafluoroborate, dipotassium hydrogen phosphate, ionic liquid 1-Hexyl-3-methylimidazolium hexafluorophosphate were added into the resulting solution. After the resulting mixture was ultrasonically shaken and centrifuged, the precipitate was separated. The acetonitrile was added in the precipitate and the analytes were extracted into the acetonitrile phase. The parameters affecting the extraction efficiency, such as volume of ionic liquid, amount of dipotassium hydrogen phosphate, volume of dispersant, extraction time and temperature were investigated. The limits of detection of sulfamethizole (STZ), sulfachlorpyridazine (SCP), sulfamethoxazole (SMX) and Sulfisoxazole (SSZ) were 4.78, 3.99, 5.21 and 3.77μgL -1 , respectively. When the present method was applied to the analysis of real blood samples, the recoveries of analytes ranged from 90.0% to 113.0% and relative standard deviations were lower than 7.2%. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Quality control of 99mTc-DTPA-octreotide by reverse high performance liquid chromatography

    International Nuclear Information System (INIS)

    Cheng, Z.; Lin, Q.F.; Jin, X.H.; Wang, F.; Bai, H.S.; Chen, D.M.; Fan, H.Q.; Du, J.

    1998-01-01

    DTPA-Octreotide(Pentetreotide), a somatostatin analogue which can bind specifically and with high affinity to somatostatin receptor in vitro and vivo, labeled with 99m Tc by tin reduction in acetate buffer, has been characterized by Reverse-phase High performance Liquid Chromatography. The effect of different solvents, mobile phase pH, linear gradient and the injected volume on the separation efficiency was evaluated. The results show that the separation efficiency is best using μBondapak-C 18 (300x3.9 mm 2 ), linear gradient of 40% to 80% methanol (1.0 ml/min) in 0.05M acetate buffer (pH 5.5) over a 30 min period and maintaining for another 10 min. The labeled product is a mixture which mainly consists of five components (a, b, c, d, e) successfully proved by HPLC. Paper chromatography is also evaluated in this paper. It may be used to determine the radiochemical purity of the labeling product, but is not a good choice for the verification each components. (author)

  15. ANALISIS RESIDU KLORPIRIFOS DALAM SAYUR-SAYURAN DENGAN TEKNIK HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC

    Directory of Open Access Journals (Sweden)

    Aman Sentosa Panggabean

    2016-06-01

    Full Text Available The research about analysis of chlorpyrifos residue in vegetables by using High Performance Liquid Chromatography (HPLC technique has been done. To obtain the optimal measurement results, the measurement performed several important parameters in the chromatographic system was composition of mobile phase, volume injection sample, flow rate and pH eluent. Optimum measurement conditions obtained was mobile phase composition (water : methanol with 70 : 30, volume injection sample are 5 mL, flow rate are 0.5mL/menit and pH eluent are 7. The analytical performance that obtained is good showed with the reproducibility value as percentage coefficient variance (% CV was 0.0664%, limit of detection (LOD was 0.44 ppm, with a recovery percentage of > 95%. The results obtained showed the HPLC technique can be used for the routine analysis in the determination of chlorpyrifos for the vegetable samples. Keywords: Chlorpyrifos, Vegetables, HPLC.

  16. Screening antiallergic components from Carthamus tinctorius using rat basophilic leukemia 2H3 cell membrane chromatography combined with high-performance liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Han, Shengli; Huang, Jing; Cui, Ronghua; Zhang, Tao

    2015-02-01

    Carthamus tinctorius, used in traditional Chinese medicine, has many pharmacological effects, such as anticoagulant effects, antioxidant effects, antiaging effects, regulation of gene expression, and antitumor effects. However, there is no report on the antiallergic effects of the components in C. tinctorius. In the present study, we investigated the antiallergic components of C. tinctorius and its mechanism of action. A rat basophilic leukemia 2H3/cell membrane chromatography coupled online with high-performance liquid chromatography and tandem mass spectrometry method was developed to screen antiallergic components from C. tinctorius. The screening results showed that Hydroxysafflor yellow A, from C. tinctorius, was the targeted component that retained on the rat basophilic leukemia 2H3/cell membrane chromatography column. We measured the amount of β-hexosaminidase and histamine released in mast cells and the key markers of degranulation. The release assays showed that Hydroxysafflor yellow A could attenuate the immunoglobulin E induced release of allergic cytokines without affecting cell viability from 1.0 to 50.0 μM. In conclusion, the established rat basophilic leukemia 2H3 cell membrane chromatography coupled with online high-performance liquid chromatography and tandem mass spectrometry method successfully screened and identified Hydroxysafflor yellow A from C. tinctorius as a potential antiallergic component. Pharmacological analysis elucidated that Hydroxysafflor yellow A is an effective natural component for inhibiting immunoglobulin E-antigen-mediated degranulation. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. EPA Method 8321B (SW-846): Solvent-Extractable Nonvolatile Compounds by High Performance Liquid Chromatography-Thermospray-Mass Spectrometry (HPLC-TS-MS) or Ultraviolet (UV) Detection

    Science.gov (United States)

    Method 8321B describes procedures for preparation and analysis of solid, aqueous liquid, drinking water and wipe samples using high performance liquid chromatography and mass spectrometry for extractable non-volatile compounds.

  18. Identification of chemical components in Baidianling Capsule based on gas chromatography-mass spectrometry and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Wu, Wenying; Chen, Yu; Wang, Binjie; Sun, Xiaoyang; Guo, Ping; Chen, Xiaohui

    2017-08-01

    Baidianling Capsule, which is made from 16 Chinese herbs, has been widely used for treating vitiligo clinically. In this study, the sensitive and rapid method has been developed for the analysis of chemical components in Baidianling Capsule by gas chromatography-mass spectrometry in combination with retention indices and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Firstly, a total of 110 potential volatile compounds obtained from different extraction procedures including alkanes, alkenes, alkynes, ketones, ethers, aldehydes, alcohols, phenols, organic acids, esters, furans, pyrrole, acid amides, heterocycles, and oxides were detected from Baidianling Capsule by gas chromatography-mass spectrometry, of which 75 were identified by mass spectrometry in combination with the retention index. Then, a total of 124 components were tentatively identified by high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Fifteen constituents from Baidianling Capsule were accurately identified by comparing the retention times with those of reference compounds, others were identified by comparing the retention times and mass spectrometry data, as well as retrieving the reference literature. This study provides a practical strategy for rapidly screening and identifying the multiple constituents of a complex traditional Chinese medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Determination of Flurbiprofen in Human Plasma by High-Performance Liquid Chromatography.

    Science.gov (United States)

    Yilmaz, Bilal; Erdem, Ali Fuat

    2015-10-01

    A simple high-performance liquid chromatography method has been developed for determination of flurbiprofen in human plasma. The method was validated on an Ace C18 column using UV detection. The mobile phase was acetonitrile-0.05 M potassium dihydrogen phosphate solution (60:40, v/v) adjusted to pH 3.5 with phosphoric acid. The calibration curve was linear between the concentration range of 0.10-5.0 μg/mL. Intra- and inter-day precision values for flurbiprofen in plasma were flurbiprofen from human plasma were between 93.0 and 98.9%. The limits of detection and quantification of flurbiprofen were 0.03 and 0.10 μg/mL, respectively. In addition, this assay was applied to determine the pharmacokinetic parameters of flurbiprofen in six healthy Turkish volunteers who had been given 100 mg flurbiprofen. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. A simple reversed phase high-performance liquid chromatography (RP-HPLC method for determination of curcumin in aqueous humor of rabbit

    Directory of Open Access Journals (Sweden)

    Akhilesh Mishra

    2014-01-01

    Full Text Available This article describes a simple and rapid method for determination of curcumin (diferuloylmethane in aqueous humor of rabbit using high-performance liquid chromatography (HPLC. Analysis was performed using a C-18 column (250 × 4.6 mm, 5 μ luna by isocratic elution with a mobile phase containing 25 mM potassium dihydrogen orthophosphate (pH 3.5: Acetonitrile (40:60 and detection at 424 nm using a photodiode array (PDA detector for curcumin. The regression data for curcumin showed a good linear relationship with r 2 > 0.998 over the concentration range of 0.1-10 μg ml−1 . Relative standard deviations (RSD for the intraday and interday coefficient of variations for the assay were less than 5.0 and 8.5, respectively. The recovery of the method was between 79.8-83.6%. The quantification limit of the method for curcumin was 0.01 μg ml−1 . This method has good accuracy, precision, and quantitation limit. It is also concluded that the method is useful for measuring very low curcumin concentrations in aqueous humor.

  1. Methacrylate-bonded covalent-organic framework monolithic columns for high performance liquid chromatography.

    Science.gov (United States)

    Liu, Li-Hua; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2017-01-06

    Covalent-organic frameworks (COFs) are a newfangled class of intriguing microporous materials. Considering their unique properties, COFs should be promising as packing materials for high performance liquid chromatography (HPLC). However, the irregular shape and sub-micrometer size of COFs synthesized via the traditional methods render the main obstacles for the application of COFs in HPLC. Herein, we report the preparation of methacrylate-bonded COF monolithic columns for HPLC to overcome the above obstacles. The prepared COF bonded monolithic columns not only show good homogeneity and permeability, but also give high column efficiency, good resolution and precision for HPLC separation of small molecules including polycyclic aromatic hydrocarbons, phenols, anilines, nonsteroidal anti-inflammatory drugs and benzothiophenes. Compared with the bare polymer monolithic column, the COF bonded monolithic columns show enhanced hydrophobic, π-π and hydrogen bond interactions in reverse phase HPLC. The results reveal the great potential of COF bonded monoliths for HPLC and COFs in separation sciences. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. [Determination of glycyrrhizinic acid in biotransformation system by reversed-phase high performance liquid chromatography].

    Science.gov (United States)

    Li, Hui; Lu, Dingqiang; Liu, Weimin

    2004-05-01

    A method for determining glycyrrhizinic acid in the biotransformation system by reversed-phase high performance liquid chromatography (RP-HPLC) was developed. The HPLC conditions were as follows: Hypersil C18 column (4.6 mm i.d. x 250 mm, 5 microm) with a mixture of methanol-water-acetic acid (70:30:1, v/v) as the mobile phase; flow rate at 1.0 mL/min; and UV detection at 254 nm. The linear range of glycyrrhizinic acid was 0.2-20 microg. The recoveries were 98%-103% with relative standard deviations between 0.16% and 1.58% (n = 3). The method is simple, rapid and accurate for determining glycyrrhizinic acid.

  3. Detection of Free Polyamines in Plants Subjected to Abiotic Stresses by High-Performance Liquid Chromatography (HPLC).

    Science.gov (United States)

    Gong, Xiaoqing; Liu, Ji-Hong

    2017-01-01

    High-performance liquid chromatography (HPLC) is a sensitive, rapid, and accurate technique to detect and characterize various metabolites from plants. The metabolites are extracted with different solvents and eluted with appropriate mobile phases in a designed HPLC program. Polyamines are known to accumulate under abiotic stress conditions in various plant species and thought to provide protection against oxidative stress by scavenging reactive oxygen species. Here, we describe a common method to detect the free polyamines in plant tissues both qualitatively and quantitatively.

  4. Determination of triazine herbicides in juice samples by microwave-assisted ionic liquid/ionic liquid dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography.

    Science.gov (United States)

    Su, Rui; Li, Dan; Wu, Lijie; Han, Jing; Lian, Wenhui; Wang, Keren; Yang, Hongmei

    2017-07-01

    A novel microextraction method, termed microwave-assisted ionic liquid/ionic liquid dispersive liquid-liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high-performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1-hexyl-3-methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1-hexyl-3-methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1-butyl-3-methylimidazolium tetrafluoroborate. In addition, an ion-pairing agent (NH 4 PF 6 ) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00-250.00 μg/L, with the correlation coefficients of 0.9982-0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7-105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. [Detection of the preservative chlorphenesin in cosmetics by high-performance liquid chromatography].

    Science.gov (United States)

    Ikarashi, Yoshiaki; Miyazawa, Norimasa; Shimamura, Kimio; Sato, Nobuo; Yoshizawa, Ken-ichi; Hayashi, Masahito; Takano, Katsuhiro; Miyamoto, Michiko; Kojima, Takashi; Sakaguchi, Hiroshi; Fujiio, Makiko

    2009-01-01

    A simple determination method for preservative chlorphenesin in cosmetics was developed. Cosmetic samples were dissolved in methanol. The sample solution was analyzed by high-performance liquid chromatography (HPLC) with ODS column, using water-methanol (55:45) or water-acetonitrile (3:1) adjusted to pH 2.5 with phosphoric acid as the mobile phase. Chlorphenesin was detected with ultraviolet light detection at 280 nm. A linear relation was obtained between the peak areas and the concentrations of chlorphenesin in the range of 1-500 microg/ml. The determination limit of chlorphenesin was 1-2 microg/ml. Recoveries of chlorphenesin spiked in lotion and milky lotion at the levels of 0.03% and 0.3% were 98.8-100.0%. This method was applied for cosmetics including 0.03% and 0.3% of chlorphenesin and their content corresponded with the determined values.

  6. Buffer-Free High Performance Liquid Chromatography Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a simple, economical and reproducible high performance liquid chromatographic (HPLC) method for the determination of theophylline in pharmaceutical dosage forms. Method: Caffeine was used as the internal standard and reversed phase C-18 column was used to elute the drug and ...

  7. Analysis of flavonoids from lotus (Nelumbo nucifera) leaves using high performance liquid chromatography/photodiode array detector tandem electrospray ionization mass spectrometry and an extraction method optimized by orthogonal design.

    Science.gov (United States)

    Chen, Sha; Wu, Ben-Hong; Fang, Jin-Bao; Liu, Yan-Ling; Zhang, Hao-Hao; Fang, Lin-Chuan; Guan, Le; Li, Shao-Hua

    2012-03-02

    The extraction protocol of flavonoids from lotus (Nelumbo nucifera) leaves was optimized through an orthogonal design. The solvent was the most important factor comparing solvent, solvent:tissue ratio, extraction time, and temperature. The highest yield of flavonoids was achieved with 70% methanol-water and a solvent:tissue ratio of 30:1 at 4 °C for 36 h. The optimized analytical method for HPLC was a multi-step gradient elution using 0.5% formic acid (A) and CH₃CN containing 0.1% formic acid (B), at a flow rate of 0.6 mL/min. Using this optimized method, thirteen flavonoids were simultaneously separated and identified by high performance liquid chromatography coupled with photodiode array detection/electrospray ionization mass spectrometry (HPLC/DAD/ESI-MS(n)). Five of the bioactive compounds are reported in lotus leaves for the first time. The flavonoid content of the leaves of three representative cultivars was assessed under the optimized extraction and HPLC analytical conditions, and the seed-producing cultivar 'Baijianlian' had the highest flavonoid content compared with rhizome-producing 'Zhimahuoulian' and wild floral cultivar 'Honglian'. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Analysis of microdialysate monoamines, including noradrenaline, dopamine and serotonin, using capillary ultra-high performance liquid chromatography and electrochemical detection.

    Science.gov (United States)

    Ferry, Barbara; Gifu, Elena-Patricia; Sandu, Ioana; Denoroy, Luc; Parrot, Sandrine

    2014-03-01

    Electrochemical methods are very often used to detect catecholamine and indolamine neurotransmitters separated by conventional reverse-phase high performance liquid chromatography (HPLC). The present paper presents the development of a chromatographic method to detect monoamines present in low-volume brain dialysis samples using a capillary column filled with sub-2μm particles. Several parameters (repeatability, linearity, accuracy, limit of detection) for this new ultrahigh performance liquid chromatography (UHPLC) method with electrochemical detection were examined after optimization of the analytical conditions. Noradrenaline, adrenaline, serotonin, dopamine and its metabolite 3-methoxytyramine were separated in 1μL of injected sample volume; they were detected above concentrations of 0.5-1nmol/L, with 2.1-9.5% accuracy and intra-assay repeatability equal to or less than 6%. The final method was applied to very low volume dialysates from rat brain containing monoamine traces. The study demonstrates that capillary UHPLC with electrochemical detection is suitable for monitoring dialysate monoamines collected at high sampling rate. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. High-performance liquid chromatography with fluorescence detection for the rapid analysis of pheophytins and pyropheophytins in virgin olive oil.

    Science.gov (United States)

    Li, Xueqi; Woodman, Michael; Wang, Selina C

    2015-08-01

    Pheophytins and pyropheophytin are degradation products of chlorophyll pigments, and their ratios can be used as a sensitive indicator of stress during the manufacturing and storage of olive oil. They increase over time depending on the storage condition and if the oil is exposed to heat treatments during the refining process. The traditional analysis method includes solvent- and time-consuming steps of solid-phase extraction followed by analysis by high-performance liquid chromatography with ultraviolet detection. We developed an improved dilute/fluorescence method where multi-step sample preparation was replaced by a simple isopropanol dilution before the high-performance liquid chromatography injection. A quaternary solvent gradient method was used to include a fourth strong solvent wash on a quaternary gradient pump, which avoided the need to premix any solvents and greatly reduced the oil residues on the column from previous analysis. This new method not only reduces analysis cost and time but shows reliability, repeatability, and improved sensitivity, especially important for low-level samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    Science.gov (United States)

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  11. High-performance liquid chromatography coupled with tandem mass spectrometry technology in the analysis of Chinese Medicine Formulas: A bibliometric analysis (1997-2015).

    Science.gov (United States)

    He, Xi-Ran; Li, Chun-Guang; Zhu, Xiao-Shu; Li, Yuan-Qing; Jarouche, Mariam; Bensoussan, Alan; Li, Ping-Ping

    2017-01-01

    There is a recognized challenge in analyzing traditional Chinese medicine formulas because of their complex chemical compositions. The application of modern analytical techniques such as high-performance liquid chromatography coupled with a tandem mass spectrometry has improved the characterization of various compounds from traditional Chinese medicine formulas significantly. This study aims to conduct a bibliometric analysis to recognize the overall trend of high-performance liquid chromatography coupled with tandem mass spectrometry approaches in the analysis of traditional Chinese medicine formulas, its significance and possible underlying interactions between individual herbs in these formulas. Electronic databases were searched systematically, and the identified studies were collected and analyzed using Microsoft Access 2010, Graph Pad 5.0 software and Ucinet software package. 338 publications between 1997 and 2015 were identified, and analyzed in terms of annual growth and accumulated publications, top journals, forms of traditional Chinese medicine preparations and highly studied formulas and single herbs, as well as social network analysis of single herbs. There is a significant increase trend in using high-performance liquid chromatography coupled with tandem mass spectrometry related techniques in analysis of commonly used forms of traditional Chinese medicine formulas in the last 3 years. Stringent quality control is of great significance for the modernization and globalization of traditional Chinese medicine, and this bibliometric analysis provided the first and comprehensive summary within this field. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. High-performance noncontact thermal diode via asymmetric nanostructures

    Science.gov (United States)

    Shen, Jiadong; Liu, Xianglei; He, Huan; Wu, Weitao; Liu, Baoan

    2018-05-01

    Electric diodes, though laying the foundation of modern electronics and information processing industries, suffer from ineffectiveness and even failure at high temperatures. Thermal diodes are promising alternatives to relieve above limitations, but usually possess low rectification ratios, and how to obtain a high-performance thermal rectification effect is still an open question. This paper proposes an efficient contactless thermal diode based on the near-field thermal radiation of asymmetric doped silicon nanostructures. The rectification ratio computed via exact scattering theories is demonstrated to be as high as 10 at a nanoscale gap distance and period, outperforming the counterpart flat-plate diode by more than one order of magnitude. This extraordinary performance mainly lies in the higher forward and lower reverse radiative heat flux within the low frequency band compared with the counterpart flat-plate diode, which is caused by a lower loss and smaller cut-off wavevector of nanostructures for the forward and reversed scheme, respectively. This work opens new routes to realize high performance thermal diodes, and may have wide applications in efficient thermal computing, thermal information processing, and thermal management.

  13. Quantitative determination of flavonoids by column high-performance liquid chromatography with mass spectrometry and ultraviolet absorption detection in Artemisia afra and comparative studies with various species of Artemisia plants.

    Science.gov (United States)

    Avula, Bharathi; Wang, Yan-Hong; Smillie, Troy J; Mabusela, Wilfred; Vincent, Leszek; Weitz, Frans; Khan, Ikhlas A

    2009-01-01

    A simple and specific analytical method for the quantitative determination of flavonoids from the aerial parts of the Artemisia afra plant samples was developed. By column high-performance liquid chromatography (HPLC) with UV absorption and mass spectrometry (MS) detection, separation was achieved on a reversed-phase octadecylsilyl (C18) column with water, methanol, and acetonitrile, all containing 0.1% acetic acid, as the mobile phase. These methods were used to analyze various species of Artemisia plant samples. The wavelength used for quantification of flavonoids with the diode array detector was 335 nm. The limits of detection (LOD) by HPLC/MS were found to be 7.5, 7.5, 10, 2.0, and 2.0 ng/mL; and by LC-UV the LODs were 500, 500, 500, 300, and 300 ng/mL for apigenin, chrysoeriol, tamarixetin, acacetin, and genkwanin, respectively. The HPLC/MS method was found to be 50-150 times more sensitive than the HPLC-UV method. HPLC/MS coupled with an electrospray ionization interface is described for the identification and quantification of flavonoids in various plant samples. This method involved the use of the [M+H]+ ions of the compounds at mass-to-charge ratio of 1.0606, 301.0712, 317.0661, 285.0763, and 285.0763 (calculated mass), respectively, in the positive ion mode with extractive ion monitoring.

  14. Determination of gouty arthritis' biomarkers in human urine using reversed-phase high-performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Lei-Wen Xiang

    2014-04-01

    Full Text Available Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in urine based on reversed-phase high-performance liquid chromatography (RP-HPLC with ultraviolet (UV detector was proposed. After pretreatment by dilution, centrifugation and filtration, the biomarkers in urine samples were separated by ODS-BP column by elution with methanol/50 mM NaH2PO4 buffer solution at pH 5.26 (5:95. Good linearity between peak areas and concentrations of standards was obtained for the biomarkers with correlation coefficients in the range of 0.9957–0.9993. The proposed analytical method has satisfactory repeatability (the recovery of data in a range of creatinine, uric acid, hypoxanthine and xanthine was 93.49–97.90%, 95.38–96.45%, 112.46–115.78% and 90.82–97.13% with standard deviation of <5%, respectively and the limits of detection (LODs, S/N≥3 for creatinine, uric acid, hypoxanthine, and xanthine were 0.010, 0.025, 0.050 and 0.025 mg/L, respectively. The established method was proved to be simple, accurate, sensitive and reliable for the quantitation of gouty arthritis' biomarkers in human urine samples. The ratio of creatinine to uric acid was found to be a possible factor for assessment of gouty arthritis. Keywords: Gouty arthritis, Creatinine, Uric acid, Hypoxanthine, Xanthine, High-performance liquid chromatography

  15. An optimized method for the measurement of acetaldehyde by high-performance liquid chromatography.

    Science.gov (United States)

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2012-03-01

    Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood, and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent, time, and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DNP) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison with AcH-DNP standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Derivatization of acetaldehyde was performed at pH 4.0 with an 80-fold molar excess of DNPH. The reaction was completed in 40 minutes at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-minute chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was volume (70 μl) plasma sampling. An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small-volume sampling of culture

  16. Simultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Mohammad Faraji

    2016-04-01

    Full Text Available Background and objectives:  High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP in foodstuff by high performance liquid chromatography. Materials and methods: Important factors in extraction, separation and determination process were optimized using the one variable at a time method.  Figures of merit of the proposed method were evaluated. The amount of SB, PS, MP, PP in some food samples were determined using the proposed method. Result: The results showed that the obtained chromatogram of extract was free of significant interferences. The preservatives recoveries ranged from 88% to 110 %. Concentration of SB, PS, MP and PP in the 20studied samples ranges between N.D-639.9, N.D -214.5, N.D -579.8 and N.D -30.5 mg kg-1, respectively  Conclusion: The performance and reliability of proposed method as a simple, efficient and fast method for determination of SB, PS, MP, PP in the food samples was demonstrated.

  17. Flexible and twistable non-volatile memory cell array with all-organic one diode-one resistor architecture.

    Science.gov (United States)

    Ji, Yongsung; Zeigler, David F; Lee, Dong Su; Choi, Hyejung; Jen, Alex K-Y; Ko, Heung Cho; Kim, Tae-Wook

    2013-01-01

    Flexible organic memory devices are one of the integral components for future flexible organic electronics. However, high-density all-organic memory cell arrays on malleable substrates without cross-talk have not been demonstrated because of difficulties in their fabrication and relatively poor performances to date. Here we demonstrate the first flexible all-organic 64-bit memory cell array possessing one diode-one resistor architectures. Our all-organic one diode-one resistor cell exhibits excellent rewritable switching characteristics, even during and after harsh physical stresses. The write-read-erase-read output sequence of the cells perfectly correspond to the external pulse signal regardless of substrate deformation. The one diode-one resistor cell array is clearly addressed at the specified cells and encoded letters based on the standard ASCII character code. Our study on integrated organic memory cell arrays suggests that the all-organic one diode-one resistor cell architecture is suitable for high-density flexible organic memory applications in the future.

  18. Simultaneous determination of acidic 3,4-dihydroxyphenylalanine metabolites and 5-hydroxyindole-3-acetic acid in urine by high-performance liquid chromatography

    NARCIS (Netherlands)

    Stroomer, A. E.; Overmars, H.; Abeling, N. G.; van Gennip, A. H.

    1990-01-01

    We describe a simple and rapid quantitative method for the simultaneous determination of 3,4-dihydroxyphenylalanine acid metabolites and 5-hydroxyindole-3-acetic acid. After solvent extraction from acidified urine, the acids are analyzed by reversed-phase high-performance liquid chromatography. For

  19. Classification of cultivation locations of Panax quinquefolius L samples using high performance liquid chromatography-electrospray ionization mass spectrometry and chemometric analysis

    Science.gov (United States)

    Panax quinquefolius L (P. quinquefolius L) samples grown in the United States and China were analyzed with high performance liquid chromatography-mass spectrometry (HPLC—MS). Prior to classification, the two-way datasets were subjected to pretreatment including baseline correction and retention tim...

  20. Determination of alpha-Tocopherol (vitamin E) in irradiated garlic by high performance liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Rios, Magda Dias Goncalves; Penteado, Marilene de Vuono Camargo

    2003-01-01

    The effects of 60 Co ionizing radiations in doses of 0, 75, 100, 150, 200 and 250Gy on garlic, upon the α-tocopherol concentration were studied. The α-tocopherol contents were established by high performance liquid chromatography (HPLC), after direct hexane extraction from the garlic samples. The α-tocopherol was determined through normal phase column, and mobile phase was composed by hexane: iso-propyl alcohol (99:01 v/v), with 2mL/min flow rate and fluorescence detector. It is statistically shown that an irradiation dose of up to 150 Gy does not affect the garlic α-tocopherol content. (author)

  1. High-performance liquid chromatography of quinoidal imminium compounds derived from triphenylmethanes

    Science.gov (United States)

    Abidi, S.L.

    1983-01-01

    A series of eleven p-aminotriphenylmethane dyes have been studied by high-performance liquid chromatography (HPLC). The combined use of HPLC and spectrophotometry permits specific detection of these compounds in the visible range around 600 nm. As the high affinity of the imminium cations for the active sites of the hydrocarbonaceous stationary phase has presented difficulties for reversed-phase HPLC with pure solvents, organic electrolytes were added to the mobile phase to facilitate the elution of the components with improved selectivity, sensitivity (minimum detection limit, 0.1 μg/ml), and peak symmetry. The effects of chromatographic variables on the component retentivity were investigated. Retention times of the dye analytes decreased with increasing concentration of the added ionic reagent and with decreasing number of the hydrophobic alkyl substituents on the nitrogen atom. The influence of pH on the retention parameters appears to parallel that observed previously for cationic quaternary ammonium compounds. Among the acidic reagents employed, naphthalenesulfonic acid yielded the most satisfactory results. The use of binary electrolyte systems invariably improved the chromatographic behavior of the imminium solutes analyzed. Results obtained with two different octadecylsilica columns have been compared.

  2. Facile and sensitive determination of N-nitrosamines in food samples by high-performance liquid chromatography via combining fluorescent labeling with dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Lu, Shuaimin; Wu, Di; Li, Guoliang; Lv, Zhengxian; Gong, Peiwei; Xia, Lian; Sun, Zhiwei; Chen, Guang; Chen, Xuefeng; You, Jinmao; Wu, Yongning

    2017-11-01

    The intake of N-nitrosamines (NAs) from foodstuffs is considered to be an important influence factor for several cancers. But the rapid and sensitive screening of NAs remains a challenge in the field of food safety. Inspired by that, a sensitive and rapid method was demonstrated for determination of five NAs (Nitrosopyrrolidine, Nitrosodimethylamine, Nitrosodiethylamine, Nitrosodipropylamine and Nitrosodibutylamine) using dispersive liquid-liquid microextraction (DLLME) followed by high-performance liquid chromatography with fluorescence detection (HPLC-FLD). The NAs were firstly denitrosated and labeled by 2-(11H-benzo[a]carbazol-11-yl) ethyl carbonochloridate (BCEC-Cl) and finally enriched by DLLME. Furthermore, the main DLLME conditions were optimized systematically. Under the optimal conditions, satisfactory limits of detection (LODs) were obtained with a range of 0.01-0.07ngg -1 , which were significantly lower than the reported methods. The developed method showed many merits including rapidity, simplicity, high sensitivity and excellent selectivity, which shows a broad prospect in food safety analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Quantitative Determination of Bioactive Constituents in Noni Juice by High-performance Liquid Chromatography with Electrospray Ionization Triple Quadrupole Mass Spectrometry.

    Science.gov (United States)

    Yan, Yongqiu; Lu, Yu; Jiang, Shiping; Jiang, Yu; Tong, Yingpeng; Zuo, Limin; Yang, Jun; Gong, Feng; Zhang, Ling; Wang, Ping

    2018-01-01

    Noni juice has been extensively used as folk medicine for the treatment of arthritis, infections, analgesic, colds, cancers, and diabetes by Polynesians for many years. Due to the lack of standard scientific evaluation methods, various kinds of commercial Noni juice with different quality and price were available on the market. To establish a sensitive, reliable, and accurate high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (HPLC-ESI-MS/MS) method for separation, identification, and simultaneous quantitative analysis of bioactive constituents in Noni juice. The analytes and eight batches of commercially available samples from different origins were separated and analyzed by the HPLC-ESI-MS/MS method on an Agilent ZORBAX SB-C 18 (150 mm × 4.6 mm i.d., 5 μm) column using a gradient elution of acetonitrile-methanol-0.05% glacial acetic acid in water (v/v) at a constant flow rate of 0.5 mL/min. Seven components were identification and all of the assay parameters were within the required limits. Components were within the correlation coefficient values ( R 2 ≥ 0.9993) at the concentration ranges tested. The precision of the assay method was high-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometryThe presented method was successfully applied to the quality control of eight batches of commercially available samples of Noni juiceThis method is simple, sensitive, reliable, accurate, and efficient method with strong specificity, good precision, and high recovery rate and provides a reliable basis for quality control of Noni juice. Abbreviations used: HPLC-ESI-MS/MS: High-performance liquid chromatography with electrospray ionization triple quadrupole mass spectrometry, LOD: Limit of detection, LOQ: Limit of quantitation, S/N: Signal-to-noise ratio, RSD: Relative standard deviations, DP: Declustering potential, CE: Collision energy, MRM: Multiple reaction monitoring, RT

  4. Integration of electrochemistry with ultra-performance liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A; Chen, Hao

    2015-01-01

    This study presents the development of ultra-performance liquid chromatography (UPLC) mass spectrometry (MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of proteins/peptides that contain disulfide bonds. In our approach, a protein/peptide mixture sample undergoes a fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and tandem mass spectrometry (MS/MS) analyses. The electrochemical cell is coupled to the mass spectrometer using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, peptides that contain disulfide bonds can be differentiated from those without disulfide bonds, as the former are electroactive and reducible. MS/MS analysis of the disulfide-reduced peptide ions provides increased information on the sequence and disulfide-linkage pattern. In a reactive DESI- MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which will be useful in top- down protein structure MS analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1(~)2 orders of magnitude by using UPLC for the liquid chromatography (LC)/EC/MS platform, in comparison to the previously used high- performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion, and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis.

  5. Automated and unbiased classification of chemical profiles from fungi using high performance liquid chromatography

    DEFF Research Database (Denmark)

    Hansen, Michael Edberg; Andersen, Birgitte; Smedsgaard, Jørn

    2005-01-01

    In this paper we present a method for unbiased/unsupervised classification and identification of closely related fungi, using chemical analysis of secondary metabolite profiles created by HPLC with UV diode array detection. For two chromatographic data matrices a vector of locally aligned full sp...

  6. High-performance liquid chromatography of metal complexes of pheophytins a and b

    International Nuclear Information System (INIS)

    Brykina, G.D.; Lazareva, E.E.; Uvarova, M.I.; Shpigun, O.A.

    1997-01-01

    Cu(2), Zn(2), Pb(2), Hg(2), and Ce(4) complexes of phenophytins a and b were synthesized. The chromatographic retention parameters of pheophytins a and b, chlorophylls a and b, and the above complexes were determined under conditions of normal-phase and reversed-phase high-performance liquid chromatography (HPLC). The adsorption of metal pheophytinates in the hexane-n-butanol (96:4)-Silasorb 600 and acetonitrile-ethanol-acetic acid (40:40:16)-Nucleosil C 18 systems was studied by HPLC. Factors that affect the chromatographic and adsorption characteristics of compounds (structural differences between pheophytinates of the a and b series, the nature of the central metal atom, and the nature of the mobile and stationary phases) are discussed. It is demonstrated that pheophytins a and b their metal complexes can be identified and quantiatively determined by HPLC in the concentration range (0.6-44.0)[10 -6 M

  7. Optimisation of pressurized liquid extraction using a multivariate chemometric approach for the determination of anticancer drugs in sludge by ultra high performance liquid chromatography-tandem mass spectrometry

    OpenAIRE

    Seira , Jordan; Claparols , Catherine; Joannis-Cassan , Claire; Albasi , Claire; Montréjaud-Vignoles , Mireille; Sablayrolles , Caroline

    2013-01-01

    International audience; The present paper describes an analytical method for the determination of 2 widely administered anticancer drugs, ifosfamide and cyclophosphamide, contained in sewage sludge. The method relies on the extraction from the solid matrix by pressurized liquid extraction, sample purification by solid-phase extraction and analysis by ultra high performance liquid chromatography coupled with tandem mass spectrometry. The different parameters affecting the extraction efficiency...

  8. Strategy for reduced calibration sets to develop quantitative structure-retention relationships in high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Andries, Jan P.M. [University of Professional Education, Department of Life Sciences, P.O. Box 90116, 4800 RA Breda (Netherlands); Claessens, Henk A. [University of Professional Education, Department of Life Sciences, P.O. Box 90116, 4800 RA Breda (Netherlands); Eindhoven University of Technology, Department of Chemical Engineering and Chemistry, Laboratory of Polymer Chemistry, P.O. Box 513 (Helix, STW 1.35), 5600 MB Eindhoven (Netherlands); Heyden, Yvan Vander [Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090 Brussels (Belgium); Buydens, Lutgarde M.C., E-mail: L.Buydens@science.ru.nl [Institute for Molecules and Materials, Radboud University Nijmegen, Toernooiveld 1, 6525 ED Nijmegen (Netherlands)

    2009-10-12

    In high-performance liquid chromatography, quantitative structure-retention relationships (QSRRs) are applied to model the relation between chromatographic retention and quantities derived from molecular structure of analytes. Classically a substantial number of test analytes is used to build QSRR models. This makes their application laborious and time consuming. In this work a strategy is presented to build QSRR models based on selected reduced calibration sets. The analytes in the reduced calibration sets are selected from larger sets of analytes by applying the algorithm of Kennard and Stone on the molecular descriptors used in the QSRR concerned. The strategy was applied on three QSRR models of different complexity, relating logk{sub w} or log k with either: (i) log P, the n-octanol-water partition coefficient, (ii) calculated quantum chemical indices (QCI), or (iii) descriptors from the linear solvation energy relationship (LSER). Models were developed and validated for 76 reversed-phase high-performance liquid chromatography systems. From the results we can conclude that it is possible to develop log P models suitable for the future prediction of retentions with as few as seven analytes. For the QCI and LSER models we derived the rule that three selected analytes per descriptor are sufficient. Both the dependent variable space, formed by the retention values, and the independent variable space, formed by the descriptors, are covered well by the reduced calibration sets. Finally guidelines to construct small calibration sets are formulated.

  9. Quantitative determination of reserpine, ajmaline, and ajmalicine in Rauvolfia serpentina by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Srivastava, A; Tripathi, A K; Pandey, R; Verma, R K; Gupta, M M

    2006-10-01

    A sensitive and reproducible reversed-phase high-performance liquid chromatography (HPLC) method using photodiode array detection is established for the simultaneous quantitation of important root alkaloids of Rauvolfia serpentina, namely, reserpine, ajmaline, and ajmalicine. A Chromolith Performance RP-18e column (100 x 4.6-mm i.d.) and a binary gradient mobile phase composed of 0.01 M (pH 3.5) phosphate buffer (NaH(2)PO(4)) containing 0.5% glacial acetic acid and acetonitrile are used. Analysis is run at a flow rate of 1.0 mL/min with the detector operated at a wavelength of 254 nm. The calibration curves are linear over a concentration range of 1-20 microg/mL (r = 1.000) for all the alkaloids. The various other aspects of analysis (i.e., peak purity, similarity, recovery, and repeatability) are also validated. For the three components, the recoveries are found to be 98.27%, 97.03%, and 98.38%, respectively. The limits of detection are 6, 4, and 8 microg/mL for ajmaline, ajmalicine, and reserpine, respectively, and the limits of quantitation are 19, 12, and 23 microg/mL for ajmaline, ajmalicine, and reserpine, respectively. The developed method is simple, reproducible, and easy to operate. It is useful for the evaluation of R. serpentina.

  10. A high-performance liquid chromatography-based radiometric assay for sucrose-phosphate synthase and other UDP-glucose requiring enzymes

    International Nuclear Information System (INIS)

    Salvucci, M.E.; Crafts-Brandner, S.J.

    1991-01-01

    A method for product analysis that eliminates a problematic step in the radiometric sucrose-phosphate synthase assay is described. The method uses chromatography on a boronate-derivatized high-performance liquid chromatography column to separate the labeled product, [14C]sucrose phosphate, from unreacted uridine 5'-diphosphate-[14C]glucose (UDP-Glc). Direct separation of these compounds eliminates the need for treatment of the reaction mixtures with alkaline phosphatase, thereby avoiding the problem of high background caused by contaminating phosphodiesterase activity in alkaline phosphatase preparations. The method presented in this paper can be applied to many UDP-Glc requiring enzymes; here the authors show its use for determining the activities of sucrose-phosphate synthase, sucrose synthase, and uridine diphosphate-glucose pyrophosphorylase in plant extracts

  11. Liquid chromatography-electrospray ionization mass spectrometry analysis of limonoids and flavanois in seeds of grapefruits, other citrus species, and dietary supplements

    Science.gov (United States)

    A selective ultra-high performance liquid chromatography-didode array detector-quadrapole time of flight-mass spectrometry (UHPLC-DAD-QToF-MS) method has been developed to screen grapefruit seeds, and other citrus seed samples for limonoid aglycones, limonoid acids, limonoid glucosides and flavonoid...

  12. Supercritical fluid extraction and ultra performance liquid chromatography of respiratory quinones for microbial community analysis in environmental and biological samples.

    Science.gov (United States)

    Hanif, Muhammad; Atsuta, Yoichi; Fujie, Koichi; Daimon, Hiroyuki

    2012-03-05

    Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE) and ultra performance liquid chromatography (UPLC) method for the analysis of bacterial respiratory quinones (RQ) in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA) detector was successfully applied to the simultaneous determination of ubiquinones (UQ) and menaquinones (MK) without tedious pretreatment. Supercritical carbon dioxide (scCO(2)) extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost) and biological samples (swine and Japanese quail feces).

  13. [Separation and identification of bovine lactoferricin by high performance liquid chromatography-matrix-assisted laser desorption/ionization time of flight/ time of flight mass spectrometry].

    Science.gov (United States)

    An, Meichen; Liu, Ning

    2010-02-01

    A high performance liquid chromatography-matrix-assisted laser desorption/ionization time of flight/time of flight mass spectrometry (HPLC-MALDI-TOF/TOF MS) method was developed for the separation and identification of bovine lactoferricin (LfcinB). Bovine lactoferrin was hydrolyzed by pepsin and then separated by ion exchange chromatography and reversed-phase liquid chromatography (RP-LC). The antibacterial activities of the fractions from RP-LC separation were determined and the protein concentration of the fraction with the highest activity was measured, whose sequence was indentified by MALDI-TOF/TOF MS. The relative molecular mass of LfcinB was 3 124.89 and the protein concentration was 18.20 microg/mL. The method of producing LfcinB proposed in this study has fast speed, high accuracy and high resolution.

  14. Automated high performance liquid chromatography and liquid scintillation counting determination of pesticide mixture octanol/water partition rates

    International Nuclear Information System (INIS)

    Moody, R.P.; Carroll, J.M.; Kresta, A.M.

    1987-01-01

    Two novel methods are reported for measuring octanol/water partition rates of pesticides. A liquid scintillation counting (LSC) method was developed for automated monitoring of 14 C-labeled pesticides partitioning in biphasic water/octanol cocktail systems with limited success. A high performance liquid chromatography (HPLC) method was developed for automated partition rate monitoring of several constituents in a pesticide mixture, simultaneously. The mean log Kow +/- SD determined from triplicate experimental runs were for: 2,4-D-DMA (2,4-dichlorophenoxyacetic acid dimethylamine), 0.65 +/- .17; Deet (N,N-diethyl-m-toluamide), 2.02 +/- .01; Guthion (O,O-dimethyl-S-(4-oxo-1,2,3-benzotriazin-3(4H)-ylmethyl) phosphorodithioate), 2.43 +/- .03; Methyl-Parathion (O,O-dimethyl-O-(p-nitrophenyl) phosphorothioate), 2.68 +/- .05; and Fenitrothion (O,O-dimethyl O-(4-nitro-m-tolyl) phosphorothioate), 3.16 +/- .03. A strong positive linear correlation (r = .9979) was obtained between log Kow and log k' (log Kow = 2.35 (log k') + 0.63). The advantages that this automated procedure has in comparison with the standard manual shake-flask procedure are discussed

  15. Rapid determination of some beta-blockers in complicated matrices by tandem dispersive liquid-liquid microextraction followed by high performance liquid chromatography.

    Science.gov (United States)

    Hemmati, Maryam; Asghari, Alireza; Bazregar, Mohammad; Rajabi, Maryam

    2016-11-01

    In this research work, an efficient tandem dispersive liquid-liquid microextraction (TDLLME) procedure coupled with high performance liquid chromatography-ultraviolet detection (HPLC-UV) was successfully applied for the determination of beta-blockers in human plasma and pharmaceutical wastewater samples. High clean-up and preconcentration factor are easily and rapidly feasible via this novel, cheap, and safe microextraction method, leading to high quality experimental data. It consists of two sequential dispersive liquid-liquid microextraction methods, accomplished via air/ultrasonic agitation and air agitation, respectively. In order to enrich the optimal values for the mentioned procedures, the Box-Behnken design (BBD) combined with the desirability function (DF) was used. The optimum values were found to be 11.0 % (w/v) of the salt amount, an initial pH value of 12.0, 103 μL of organic extractant phase, and 45 μL of aqueous extractant phase with pH value of 2.0, resulted in reasonable recovery percentages with a logical desirability. Under optimal experimental conditions, good linear ranges (3-2000 ng mL -1 for metoprolol and 2.5-2500 ng mL -1 for propranolol with the correlation of determinations (R 2 s) higher than 0.99) and low limits of detection (0.8 and 1.0 ng mL -1 for propranolol and metoprolol, respectively) were obtainable. Also, TDLLME-HPLC-UV provided good proper repeatabilities (relative standard deviations (RSDs) below 5.7 %, n = 3) and high enrichment factors (EFs) of 75-100. Graphical abstract TDLLME of beta-blockers from complicated matrices.

  16. Simultaneous determination and qualitative analysis of six types of components in Naoxintong capsule by miniaturized matrix solid-phase dispersion extraction coupled with ultra high-performance liquid chromatography with photodiode array detection and quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Wang, Huilin; Jiang, Yan; Ding, Mingya; Li, Jin; Hao, Jia; He, Jun; Wang, Hui; Gao, Xiu-Mei; Chang, Yan-Xu

    2018-02-03

    A simple and effective sample preparation process based on miniaturized matrix solid-phase dispersion was developed for simultaneous determination of phenolic acids (gallic acid, chlorogenic acid, ferulic acid, 3,5-dicaffeoylqunic acid, 1,5-dicaffeoylqunic acid, rosmarinic acid, lithospermic acid, and salvianolic acid B), flavonoids (kaempferol-3-O-rutinoside, calycosin, and formononetin), lactones (ligustilide and butyllidephthalide), monoterpenoids (paeoniflorin), phenanthraquinones (cryptotanshinone), and furans (5-hydroxymethylfurfural) in Naoxintong capsule by ultra high-performance liquid chromatography. The optimized condition was that 25 mg Naoxintong powder was blended homogeneously with 100 mg Florisil PR for 4 min. One milliliter of methanol/water (75:25, v/v) acidified by 0.05% formic acid was selected to elute all components. It was found that the recoveries of the six types of components ranged from 61.36 to 96.94%. The proposed miniaturized matrix solid-phase dispersion coupled with ultra high-performance liquid chromatography was successfully applied to simultaneous determination of the six types of components in Naoxintong capsules. The results demonstrated that the proposed miniaturized matrix solid-phase dispersion coupled with ultra high-performance liquid chromatography could be used as an environmentally friendly tool for the extraction and determination of multiple bioactive components in natural products. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. L-ascorbic acid losses in Kenyan vegetables during cooking as determined by high performance liquid chromatography

    OpenAIRE

    N.M.N. Wekesa; S.C. Chhabra; H.M. Thairu

    2001-01-01

    The loss of L-ascorbic acid (L-AA) in 14 different cooked local vegetables found in Nairobi markets was determined by high performance liquid chromatography. The effect of quantity of water on the loss of L-AA during cooking was studied with cowpea leaves. It was found that more L-AA was lost when larger amount of water was used than when smaller amount was used. The effect of the sharpness of the knife on the loss of L-AA was studied with spinach. It was found that more loss of L-AA occurred...

  18. Determination of 2-naphthylamine in urine by a novel reversed-phase high-performance liquid chromatography method

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Poulsen, O M; Christensen, J M

    1992-01-01

    A high-performance liquid chromatographic method for the determination of 2-naphthylamine in urine using fluorescence detection was developed. The method validation analysis showed the method to be in analytical control, i.e. the distribution of the difference between the observed and true values...... of the method evaluation samples did not deviate significantly from the normal distribution. The recovery of the method was 85%. The entire run time of chromatography was 10 min using isocratic elution (acetonitrile-water, 35:65), and the retention time for 2-naphthylamine was 5.8 min. The relative short time...

  19. Determination of statin drugs in hospital effluent with dispersive liquid-liquid microextraction and quantification by liquid chromatography.

    Science.gov (United States)

    Martins, Ayrton F; Frank, Carla da S; Altissimo, Joseline; de Oliveira, Júlia A; da Silva, Daiane S; Reichert, Jaqueline F; Souza, Darliana M

    2017-08-24

    Statins are classified as being amongst the most prescribed agents for treating hypercholesterolaemia and preventing vascular diseases. In this study, a rapid and effective liquid chromatography method, assisted by diode array detection, was designed and validated for the simultaneous quantification of atorvastatin (ATO) and simvastatin (SIM) in hospital effluent samples. The solid phase extraction (SPE) of the analytes was optimized regarding sorbent material and pH, and the dispersive liquid-liquid microextraction (DLLME), in terms of pH, ionic strength, type and volume of extractor/dispersor solvents. The performance of both extraction procedures was evaluated in terms of linearity, quantification limits, accuracy (recovery %), precision and matrix effects for each analyte. The methods proved to be linear in the concentration range considered; the quantification limits were 0.45 µg L -1 for ATO and 0.75 µg L -1 for SIM; the matrix effect was almost absent in both methods and the average recoveries remained between 81.5-90.0%; and the RSD values were <20%. The validated methods were applied to the quantification of the statins in real samples of hospital effluent; the concentrations ranged from 18.8 µg L -1 to 35.3 µg L -1 for ATO, and from 30.3 µg L -1 to 38.5 µg L -1 for SIM. Since the calculated risk quotient was ≤192, the occurrence of ATO and SIM in hospital effluent poses a potential serious risk to human health and the aquatic ecosystem.

  20. [Determination of sulpride in human plasma by high performance liquid chromatography].

    Science.gov (United States)

    Yu, X; Luo, Z; Tang, J; Yu, P

    1997-11-01

    This paper describes a reliable method for the pharmacokinetic study of Sulpride in human plasma by reversed-phase high performance liquid chromatography. To compensate the loss of Sulpride during the extraction procedure we used an internal standard very similar in chemical structure and UV absorbance to those of Sulpride. The mobile phase was methanol-water-acetic acid (60:30:1) with a flow rate of 1.2 mL/min. A UV detector was used at 290 nm. The linear range was 5-100 mg/L and the detectable limit was 1.0 mg/L. The recovery and RSD were 97.95%-99.96% and 2.6%-5.1% respectively. The results showed that this method is a sensitive and accurate one which makes the pharmacokinetic study of Sulpride possible. If the concentration was too low to be detected by UV monitor, a fluorescence detector could be used with the excitation wavelength at 299 nm and emission at 342 nm. We analyzed the plasma samples from 30 day-treated psychotic patients and got the satisfactory results.

  1. The high pressure electronic control system in liquid chromatography

    International Nuclear Information System (INIS)

    Popescu, Stefan; Popeneciu, Gabriel; Toadere, Florin

    2002-01-01

    The Liquid Chromatography system can perform a wide variety of measurements and separations especially for the organic liquids, with maximum applications flexibility for less than half price of Gas Chromatography. The repeatability and accuracy of results in quantitative high pressure liquid chromatography are highly dependent on the reproducibility and accuracy of both integrated flow rate and mobile phase composition. Flow rate fluctuation leads to poor reproducibility in both integrated peak areas and retention times. Similarly, poor control of mobile phase composition will cause poor repeatability of retention time and peak heights. The our Solvent Delivery System SDS 200 is a single pump system which provides precise compensated flow rates from 0.01 to 10 mL/min, selectable upper pressure limits of 0 to 100 bar or 10 to 450 bar, and solvent compressibility correction. Ternary solvent system on-line mixing capability saves time, reduces solvent waste and provides more flexibility for difficult separations. The pump itself has two different displacement pistons which are used alternately on both suction and discharge, so that intake of the solvent are synchronous. The evacuated solvent from the two pump's chambers is mixed in the reference unit and then is supplied to the damping unit for flow ripple reduction. The SDS Electronic Module ensures the functions: controls the programmed flow rate, detects and shows the solvent pressure in solvent, supplies the step motor, measures and limits the solvent pressure. The control panel of SDS 200, contains a two-stages flow decimal programmer, a eight-positions knob for upper pressure limits, an alarm LED and a parallel port for connection to a PC system. (authors)

  2. Quantitative Analysis of Ingenol in Euphorbia species via Validated Isotope Dilution Ultra-high Performance Liquid Chromatography Tandem Mass Spectrometry

    Czech Academy of Sciences Publication Activity Database

    Béres, T.; Dragull, K.; Pospíšil, Jiří; Tarkowská, Danuše; Dančák, M.; Bíba, Ondřej; Tarkowski, P.; Doležal, K.; Strnad, Miroslav

    2018-01-01

    Roč. 29, č. 1 (2018), s. 23-29 ISSN 0958-0344 R&D Projects: GA ČR GA17-14007S; GA MŠk(CZ) LO1204 Institutional support: RVO:61389030 Keywords : Euphorbia genus * ingenol * isotope-dilution method * mass spectrometry * ultra-high performance liquid chromatography Subject RIV: FD - Oncology ; Hematology OBOR OECD: Analytical chemistry Impact factor: 2.292, year: 2016

  3. Optimized method for the determination of itopride in human plasma by high-performance liquid chromatography with fluorimetric detection.

    Science.gov (United States)

    Ptácek, Pavel; Klíma, Josef; Macek, Jan

    2009-03-15

    A high-performance liquid chromatographic method with fluorescence detection for the determination of itopride in human plasma is reported. The sample preparation was based on liquid-liquid extraction of itopride from plasma with t-butylmethylether and dichloromethane (70:30, v/v) mixture followed by a back extraction of the analyte to the phosphate buffer (pH 3.2). Liquid chromatography was performed on an octadecylsilica column (55 mm x 4 mm, 3 microm particles), the mobile phase consisted of acetonitrile-triethylamine-15 mM dihydrogenpotassium phosphate (14.5:0.5:85, v/v/v), pH of the mobile phase was adjusted to 4.8. The run time was 3 min. The fluorimetric detector was operated at 250/342 nm (excitation/emission wavelength). Naratriptan was used as the internal standard. The limit of quantitation was 9.5 ng/ml using 0.5 ml of plasma. The method precision and inaccuracy were less than 8%. The assay was applied to the analysis of samples from a bioequivalence study.

  4. Screening bioactive quality control markers of QiShenYiQi dripping pills based on the relationship between the ultra-high performance liquid chromatography fingerprint and vascular protective activity.

    Science.gov (United States)

    Zhuo, Limeng; Peng, Jingjing; Zhao, Yunli; Li, Dongxiang; Xie, Xiuman; Tong, Ling; Yu, Zhiguo

    2017-10-01

    Traditional Chinese medicine consists of complex phytochemical constituents. Selecting appropriate analytical markers of traditional Chinese medicine is a critical step in quality control. Currently, the combination of fingerprinting and efficacy evaluation is considered as a useful method for screening active ingredients in complex mixtures. This study was designed to develop an orthogonal partial least squares model for screening bioactive quality control markers of QishenYiqi dripping pills based on the fingerprint-efficacy relationship. First, the chemical fingerprints of 49 batches of QishenYiqi dripping pill samples were established by ultra-high performance liquid chromatography coupled with a photodiode array detector. Second, ultra-high performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry was exploited to systematically investigate the 36 copossessing fingerprint components in QishenYiqi dripping pills. The vascular protective activity of QishenYiqi dripping pills was determined by using a cell counting kit-8 assay. Finally, fingerprint-efficacy relationship was established by orthogonal partial least squares model. The results indicated that ten components exhibited strong correlation with vascular protective activity, and these were preliminarily screened as quality control markers. The present study provided a novel idea for the study of the pharmacodynamic material basis and quality evaluation of QishenYiqi dripping pills. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Analysis of Nitro-aromatic and Nitramine Explosives by Atmospheric Pressure Chemical Ionization / High Performance Liquid Chromatography / Mass Spectrometry / Mass Spectrometry

    International Nuclear Information System (INIS)

    Hicks, B.J.; Han, W.; Robben, J.R.

    2009-01-01

    This procedure is capable of separating and quantifying twenty-nine high explosives and internal surrogates with a single injection. After the initial preparation step, the sample is introduced to the high performance liquid chromatograph for target separation, ionized by atmospheric pressure chemical ionization and the explosives of interest are isolated / quantified by mass spectrometry / mass spectrometry. Concentrations of the target explosives are measured relative to the response of both internal and external standard concentrations. A C-18 reverse phase high performance liquid chromatograph column is used for separation. Ionization is performed using both positive and negative atmospheric pressure chemical ionization resulting in a molecular ion with little fragmentation. These ions are isolated at the first quadrupole of the mass spectrometer, dissociated by collision with argon in the collision cell and the resulting daughter ions are isolated at the second quadrupole. These daughter ions then reach the detector where they are quantified. To date this procedure represents the most thorough high performance liquid chromatography / mass spectrometry / mass spectrometry explosives analysis available in the environmental chemistry market. (authors)

  6. Comprehensive analysis of chemical constituents in Xingxiong injection by high performance liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Guo, Long; Dou, Li-Li; Duan, Li; Liu, Ke; Bi, Zhi-Ming; Li, Ping; Liu, E-Hu

    2015-09-01

    Xingxiong injection (XXI) is a widely used Chinese herbal formula prepared by the folium ginkgo extract and ligustrazine for the treatment of cardiovascular and cerebrovascular diseases. Compared with the pharmacological studies, chemical analysis and quality control studies on this formula are relatively limited. In the present study, a high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (HPLC-QTOF MS) method was applied to comprehensive analysis of constituents in XXI. According to the fragmentation rules and previous reports, thirty ginkgo flavonoids, four ginkgo terpene lactones, and one alkaloid were identified. A high performance liquid chromatography coupled with triple quadrupole mass spectrometry (HPLC-QQQ MS) method was then applied to quantify ten major constituents in XXI. The method validation results indicated that the developed method had desirable specificity, linearity, precision and accuracy. The total contents of ginkgo flavonoids were about 22.05-25.51 μg·mL(-1) and the ginkgo terpene lactones amounts were about 4.41-8.70 μg·mL(-1) in six batches of XXI samples, respectively. Furthermore, cosine ratio algorithm and distance measurements were employed to evaluate the similarity of XXI samples, and the results demonstrated a high-quality consistency. This work could provide comprehensive information on the quality control of Xingxiong injection, which be helpful in the establishment of a rational quality control standard. Copyright © 2015 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  7. Salting-out assisted liquid-liquid extraction coupled to ultra-high performance liquid chromatography-tandem mass spectrometry for the determination of tetracycline residues in infant foods.

    Science.gov (United States)

    Moreno-González, David; García-Campaña, Ana M

    2017-04-15

    The use of salting-out assisted liquid-liquid extraction (SALLE) combined with ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) has been evaluated for the determination of tetracyclines in infant foods based on meat and vegetables or in milk. To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized. Analytical performances of the method were satisfactory, obtaining limits of quantification lower than 0.48μgkg -1 in all cases. The precision, expressed as relative standard deviation (%, RSD) was below 11.3%. The extraction efficiency for fortified samples ranged from 89.2 to 96.8%, with RSDs lower than 7.3%. Matrix effect was evaluated for all samples studied, being lower than |21|% in all cases. In relation to the low solvent consumption, the proposed methodology could be considered rapid, cheap and environmentally friendly. Its applicability has been successfully tested in a wide range of infant foods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Determination of Alternaria mycotoxins in wine and juice using ionic liquid modified countercurrent chromatography as a pretreatment method followed by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Chen; Cao, Xueli; Liu, Man; Wang, Wei

    2016-03-04

    Alternariol (AOH), alternariol monomethyl ether (AME), and tenuazonic acid (TeA) are some of the main Alternaria mycotoxins that can be found as contaminants in food materials. The objective of this study was to develop a pretreatment method with countercurrent chromatography (CCC) for enrichment and cleanup of trace Alternaria mycotoxins in food samples prior to high-performance liquid chromatography (HPLC) analysis. An Analytical CCC instrument with a column volume 22.5mL was used, and a two-phase solvent system composed of ethyl acetate and water modified with 6% [HOOMIM][Cl] in mass to volume ratio was selected. Under the optimized CCC operation conditions, trace amounts of AOH, AME, and TeA in large volume of liquid sample were efficiently extracted and enriched in the stationary phase, and then eluted out just by reversing the stationary phase as mobile phase in the opposite flowing direction tail-to-head. The enrichment and elution strategies are unique and can be fulfilled online with high enrichment factors (87-114) and high recoveries (81.14-110.94%). The method has been successively applied to the determination of Alternaria mycotoxins in real apple juice and wine samples with the limits of detection (LOD) in the range of 0.03-0.14μgL(-1). Totally 12 wine samples and 15 apple juice samples from the local market were analyzed. The detection rate of AOH and AME in both kinds of the samples were more than 50%, while TeA was found in relatively high level of 1.75-49.61μgL(-1) in some of the apple juice samples. The proposed method is simple, rapid, and sensitive and could also be used for the analysis and monitoring of Alternaria mycotoxin in other food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Cation exchange separation of 16 rare earth metals by microscale high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Ishii, D.; Hirose, A.; Iwasaki, Y.

    1978-01-01

    The separation of rare earth metals has been studied with a microcolumn of 0.5 mm i.d. and 75 mm length, packed with TSK LS-212 high-performance cation exchange resin. A micro-feeder (Model MF-2, from Azumadenki Kogyo) was used to drive carrier and sample solutions through the ion exchange column and detection cell. By combining a 250 μl syringe and a 0.5 mm i.d. sampling tube the micro-feeder, 0.1-1.0 μl rare earth metals were separated within 38 min, using only 304 μl of 0.4M α-hydroxy-isobutyric acid solution adjusted to pH 3.1-6.0 with ammonia solution as gradient carrier solution. The gradient elution was successfully performed by applying a new technique developed for microscale liquid chromatography. (author)

  10. Method Development and Validation for the Determination of Caffeine: An Alkaloid from Coffea arabica by High-performance Liquid Chromatography Method.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Deepak, M; Medhini, B; Prasad, K Shyam

    2018-01-01

    The present study was investigated to develop and validate a reversed phase high performance liquid chromatography method for the determination of caffeine from bean material of Coffee arabica. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of water: methanol (50:50) at a flow rate of 1.0 mlmin-1. The detection was carried out on a UV detector at 272 nm. The developed method was validated according to the requirements for International Conference on Harmonisation (ICH) guidelines, which includes specificity, linearity, precision, accuracy, limit of detection and limit of quantitation. The developed method validates good linearity with excellent correlation coefficient (R2 > 0.999). In repeatability and intermediate precision, the percentage relative standard deviation (% RSD) of peak area was less than 1% shows high precision of the method. The recovery rate for caffeine was within 98.78% - 101.28% indicates high accuracy of the method. The low limit of detection and limit of quantitation of caffeine enable the detection and quantitation of caffeine from C. arabica at low concentrations. The developed HPLC method is a simple, rapid, precisely, accurately and widely accepted and it is recommended for efficient assays in routine work. A simple, accurate, and sensitive high-performance liquid chromatography (HPLC) method for caffeine from Coffea arabica has been developed and validated. The developed HPLC method was validated for linearity, specificity, precision, recovery, limits of detection, and limits of quantification by the International Conference on Harmonization guidelines. The results revealed that the proposed method is highly reliable. This method could be successfully applied for routine quality work analysis. Abbreviation Used: C. arabica : Coffee arabica, ICH: International Conference on Harmonisation, % RSD: Percentage Relative Standard Deviation, R2: Correlation Coefficient, ppm: Parts per million, LOD: Limits

  11. Binary Solvents Dispersive Liquid-Liquid Microextraction (BS-DLLME) Method for Determination of Tramadol in Urine Using High-Performance Liquid Chromatography.

    Science.gov (United States)

    Kiarostami, Vahid; Rouini, Mohamad-Reza; Mohammadian, Razieh; Lavasani, Hoda; Ghazaghi, Mehri

    2014-02-03

    Tramadol is an opioid, synthetic analog of codeine and has been used for the treatment of acute or chronic pain may be abused. In this work, a developed Dispersive liquid liquid microextraction (DLLME) as binary solvents-based dispersive liquid-liquid microextraction (BS-DLLME) combined with high performance liquid chromatography (HPLC) with fluorescence detection (FD) was employed for determination of tramadol in the urine samples. This procedure involves the use of an appropriate mixture of binary extraction solvents (70 μL CHCl3 and 30 μL ethyl acetate) and disperser solvent (600 μL acetone) for the formation of cloudy solution in 5 ml urine sample comprising tramadol and NaCl (7.5%, w/v). After centrifuging, the small droplets of extraction solvents were precipitated. In the final step, the HPLC with fluorescence detection was used for determination of tramadol in the precipitated phase. Various factors on the efficiency of the proposed procedure were investigated and optimized. The detection limit (S/N = 3) and quantification limit (S/N = 10) were found 0.2 and 0.9 μg/L, respectively. The relative standard deviations (RSD) for the extraction of 30 μg L of tramadol was found 4.1% (n = 6). The relative recoveries of tramadol from urine samples at spiking levels of 10, 30 and 60 μg/L were in the range of 95.6 - 99.6%. Compared with other methods, this method provides good figures of merit such as good repeatability, high extraction efficiency, short analysis time, simple procedure and can be used as microextraction technique for routine analysis in clinical laboratories.

  12. Analytical method for high resolution liquid chromatography for quality control French Macaw

    International Nuclear Information System (INIS)

    Garcia Penna, Caridad M; Torres Amaro, Leonid; Menendez Castillo, Rosa; Sanchez, Esther; Martinez Espinosa, Vivian; Gonzalez, Maria Lidia; Rodriguez, Carlos

    2007-01-01

    Was developed and validated an analytical method for high resolution liquid chromatography applicable to quality control of drugs dry French Macaw (Senna alata L. Roxb.) With ultraviolet detection at 340 nm. The method for high resolution liquid chromatography used to quantify the sennosides A and B, main components, was validated and proved to be specific, linear, precise and accurate. (Author)

  13. Ultra-high-performance liquid chromatography-tandem mass spectrometry measurement of climbazole deposition from hair care products onto artificial skin and human scalp

    NARCIS (Netherlands)

    Chen, G.; Hoptroff, M.; Fei, X.; Su, Y.; Janssen, H.-G.

    2013-01-01

    A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal

  14. Comprehensive sample analysis using high performance liquid chromatography with multi-detection.

    Science.gov (United States)

    Pravadali, Sercan; Bassanese, Danielle N; Conlan, Xavier A; Francis, Paul S; Smith, Zoe M; Terry, Jessica M; Shalliker, R Andrew

    2013-11-25

    Herein we assess the separation space offered by a liquid chromatography system with an optimised uni-dimensional separation for the determination of the key chemical entities in the highly complex matrix of a tobacco leaf extract. Multiple modes of detection, including UV-visible absorbance, chemiluminescence (acidic potassium permanganate, manganese(IV), and tris(2,2'-bipyridine)ruthenium(III)), mass spectrometry and DPPH radical scavenging were used in an attempt to systematically reduce the data complexity of the sample whilst obtaining a greater degree of molecule-specific information. A large amount of chemical data was obtained, but several limitations in the ability to assign detector responses to particular compounds, even with the aid of complementary detection systems, were observed. Thirty-three compounds were detected via MS on the tobacco extract and 12 out of 32 compounds gave a peak height ratio (PHR) greater than 0.33 on one or more detectors. This paper serves as a case study of these limitations, illustrating why multidimensional chromatography is an important consideration when developing a comprehensive chemical detection system. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. High Performance Liquid Chromatography-mass Spectrometry Analysis of High Antioxidant Australian Fruits with Antiproliferative Activity Against Cancer Cells.

    Science.gov (United States)

    Sirdaarta, Joseph; Maen, Anton; Rayan, Paran; Matthews, Ben; Cock, Ian Edwin

    2016-05-01

    145 unique mass signals were detected in the lemon aspen methanolic and aqueous extracts by nonbiased high-performance liquid chromatography-mass spectrometry analysis. Of these, 20 compounds were identified as being of particular interest due to their reported antioxidant and/or anticancer activities. The lack of toxicity and antiproliferative activity of the high antioxidant plant extracts against HeLa and CaCo2 cancer cell lines indicates their potential in the treatment and prevention of some cancers. Australian fruit extracts with high antioxidant contents were potent inhibitors of CaCo2 and HeLa carcinoma cell proliferationMethanolic lemon aspen extract was particularly potent, with IC50 values of 480 μg/mL (HeLa) and 769 μg/mL (CaCo2)High-performance liquid chromatography-mass spectrometry-quadrupole time-of-flight analysis highlighted and putatively identified 20 compounds in the antiproliferative lemon aspen extractsIn contrast, lower antioxidant content extracts stimulated carcinoma cell proliferationAll extracts with antiproliferative activity were nontoxic in the Artemia nauplii assay. Abbreviations used: DPPH: di (phenyl)- (2,4,6-trinitrophenyl) iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry.

  16. High Performance Liquid Chromatography-mass Spectrometry Analysis of High Antioxidant Australian Fruits with Antiproliferative Activity Against Cancer Cells

    Science.gov (United States)

    Sirdaarta, Joseph; Maen, Anton; Rayan, Paran; Matthews, Ben; Cock, Ian Edwin

    2016-01-01

    g/mL). All other extracts were nontoxic. A total of 145 unique mass signals were detected in the lemon aspen methanolic and aqueous extracts by nonbiased high-performance liquid chromatography-mass spectrometry analysis. Of these, 20 compounds were identified as being of particular interest due to their reported antioxidant and/or anticancer activities. Conclusions: The lack of toxicity and antiproliferative activity of the high antioxidant plant extracts against HeLa and CaCo2 cancer cell lines indicates their potential in the treatment and prevention of some cancers. SUMMARY Australian fruit extracts with high antioxidant contents were potent inhibitors of CaCo2 and HeLa carcinoma cell proliferationMethanolic lemon aspen extract was particularly potent, with IC50 values of 480 μg/mL (HeLa) and 769 μg/mL (CaCo2)High-performance liquid chromatography-mass spectrometry-quadrupole time-of-flight analysis highlighted and putatively identified 20 compounds in the antiproliferative lemon aspen extractsIn contrast, lower antioxidant content extracts stimulated carcinoma cell proliferationAll extracts with antiproliferative activity were nontoxic in the Artemia nauplii assay. Abbreviations used: DPPH: di (phenyl)- (2,4,6-trinitrophenyl) iminoazanium, HPLC: High-performance liquid chromatography, IC50: The concentration required to inhibit by 50%, LC50: The concentration required to achieve 50% mortality, MS: Mass spectrometry. PMID:27279705

  17. Bioconversion of red ginseng saponins in the gastro-intestinal tract in vitro model studied by high-performance liquid chromatography-high resolution Fourier transform ion cyclotron resonance mass spectrometry

    NARCIS (Netherlands)

    Kong, H.; Wang, M.; Venema, K.; Maathuis, A.; Heijden, R. van der; Greef, J. van der; Xu, G.; Hankemeier, T.

    2009-01-01

    A high-performance liquid chromatography-high resolution Fourier transform ion cyclotron resonance mass spectrometry (HPLC-FTICR-MS) method was developed to investigate the metabolism of ginsenosides in in vitro models of the gastro-intestinal tract. The metabolites were identified by

  18. Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Jia Xiaoyu; Han Yi; Liu Xinli; Duan Taicheng; Chen Hangting

    2011-01-01

    The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg + ) and mercury (Hg 2+ ) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg + and Hg 2+ were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL -1 for MeHg + and 0.0014 ng mL -1 for Hg 2+ , respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL -1 MeHg + and Hg 2+ were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.

  19. Dehydroepiandrosterone sulfate quantification in serum using high-performance liquid chromatography/mass spectrometry and a deuterated internal standard: a technique suitable for routine use or as a reference method

    International Nuclear Information System (INIS)

    Shackleton, C.H.; Kletke, C.; Wudy, S.; Pratt, J.H.

    1990-01-01

    A thermospray high-performance liquid chromatography/mass spectrometry method for determination of serum dehydroepiandrosterone sulfate is described. The steroid was measured intact using [7,7-2H2]dehydroepiandrosterone sulfate as internal standard. The analysis was carried out in the negative ion mode by determining the peak height ratio of the molecular anions of the analyte and internal standard. The method was used to determine the steroid in serum from 15 male and female normal adults and the following values were obtained: males, 272 +/- 45 micrograms/dl (range, 197 to 331 micrograms/dl) and females, 215 +/- 67 micrograms/dl (range, 107 to 347 micrograms/dl). In addition, dehydroepiandrosterone sulfate was measured by high-performance liquid chromatography/mass spectrometry and radioimmunoassay (a commercial kit) on 25 individuals of all age groups. There was strong correlation between the values obtained, but the radioimmunoassay values were generally double those obtained by high-performance liquid chromatography/mass spectrometry. Three other steroid sulfates, androsterone sulfate, epiandrosterone sulfate, and androst-5-ene-3 beta, 17 beta-diol sulfate, were also assayed. In males, these had mean values of 112, 44, and 13 micrograms/dl and, in females, they had mean values of 84, 25, and 6 micrograms/dl, respectively. Radioimmunoassay cross-reactivity measurement for these steroids (as reference compounds) showed that they were unlikely to contribute greatly to the discrepancy between radioimmunoassay and high-performance liquid chromatography/mass spectrometry values

  20. Investigation into the temporal stability of aqueous standard solutions of psilocin and psilocybin using high performance liquid chromatography.

    Science.gov (United States)

    Anastos, N; Barnett, N W; Pfeffer, F M; Lewis, S W

    2006-01-01

    This paper reports an investigation into the temporal stability of aqueous solutions of psilocin and psilocybin reference drug standards over a period of fourteen days. This study was performed using high performance liquid chromatography utilising a (95:5% v/v) methanol: 10 mM ammonium formate, pH 3.5 mobile phase and absorption detection at 269 nm. It was found that the exclusion of light significantly prolonged the useful life of standards, with aqueous solutions of both psilocin and psilocybin being stable over a period of seven days.

  1. Multi-detection of corticosteroids in sports doping and veterinary control using high-resolution liquid chromatography/time-of-flight mass spectrometry

    NARCIS (Netherlands)

    Touber, M.E.; Engelen, M.C.; Georgakopoulus, C.; Rhijn, van J.A.; Nielen, M.W.F.

    2007-01-01

    A liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) method was developed using the latest high-resolution LC column technology, the ultra performance liquid chromatography (UPLC (TM)), and electrospray ionization (ESI) in the positive ion mode. Gradient UPLC separation conditions

  2. Retention of nucleic acids in ion-pair reversed-phase high-performance liquid chromatography depends not only on base composition but also on base sequence.

    Science.gov (United States)

    Qiao, Jun-Qin; Liang, Chao; Wei, Lan-Chun; Cao, Zhao-Ming; Lian, Hong-Zhen

    2016-12-01

    The study on nucleic acid retention in ion-pair reversed-phase high-performance liquid chromatography mainly focuses on size-dependence, however, other factors influencing retention behaviors have not been comprehensively clarified up to date. In this present work, the retention behaviors of oligonucleotides and double-stranded DNAs were investigated on silica-based C 18 stationary phase by ion-pair reversed-phase high-performance liquid chromatography. It is found that the retention of oligonucleotides was influenced by base composition and base sequence as well as size, and oligonucleotides prone to self-dimerization have weaker retention than those not prone to self-dimerization but with the same base composition. However, homo-oligonucleotides are suitable for the size-dependent separation as a special case of oligonucleotides. For double-stranded DNAs, the retention is also influenced by base composition and base sequence, as well as size. This may be attributed to the interaction of exposed bases in major or minor grooves with the hydrophobic alky chains of stationary phase. In addition, no specific influence of guanine and cytosine content was confirmed on retention of double-stranded DNAs. Notably, the space effect resulted from the stereostructure of nucleic acids also influences the retention behavior in ion-pair reversed-phase high-performance liquid chromatography. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Screening of Carotenoids in Tomato Fruits by Using Liquid Chromatography with Diode Array-Linear Ion Trap Mass Spectrometry Detection.

    Science.gov (United States)

    Gentili, Alessandra; Caretti, Fulvia; Ventura, Salvatore; Pérez-Fernández, Virginia; Venditti, Alessandro; Curini, Roberta

    2015-08-26

    This paper presents an analytical strategy for a large-scale screening of carotenoids in tomato fruits by exploiting the potentialities of the triple quadrupole-linear ion trap hybrid mass spectrometer (QqQLIT). The method involves separation on C30 reversed-phase column and identification by means of diode array detection (DAD) and atmospheric pressure chemical ionization-mass spectrometry (APCI-MS). The authentic standards of six model compounds were used to optimize the separative conditions and to predict the chromatographic behavior of untargeted carotenoids. An information dependent acquisition (IDA) was performed with (i) enhanced-mass scan (EMS) as the survey scan, (ii) enhanced-resolution (ER) scan to obtain the exact mass of the precursor ions (16-35 ppm), and (iii) enhanced product ion (EPI) scan as dependent scan to obtain structural information. LC-DAD-multiple reaction monitoring (MRM) chromatograms were also acquired for the identification of targeted carotenoids occurring at low concentrations; for the first time, the relative abundance between the MRM transitions (ion ratio) was used as an extra tool for the MS distinction of structural isomers and the related families of geometrical isomers. The whole analytical strategy was high-throughput, because a great number of experimental data could be acquired with few analytical steps, and cost-effective, because only few standards were used; when applied to characterize some tomato varieties ('Tangerine', 'Pachino', 'Datterino', and 'Camone') and passata of 'San Marzano' tomatoes, our method succeeded in identifying up to 44 carotenoids in the 'Tangerine'" variety.

  4. Analysis of Caffeic Acid Extraction From Ocimum gratissimum Linn. by High Performance Liquid Chromatography and its Effects on a Cervical Cancer Cell Line

    Directory of Open Access Journals (Sweden)

    Je-Chiuan Ye

    2010-09-01

    Conclusion: This paper shows that high performance liquid chromatography is a suitable analytical method for determining caffeic acid levels in O. gratissimum, Ju ZenTa, and several vegetable oils. Caffeic acid can suppress the proliferation of HeLa cells.

  5. Validation of a technique by high-performance liquid chromatography for the determination of total isoflavones

    Directory of Open Access Journals (Sweden)

    Pilar A. Soledispa Cañarte

    2017-04-01

    Full Text Available Context: Isoflavones may act as selective regulators in the prevention of various diseases. The most important source of isoflavones is the soy, from which different phytotherapeutics are elaborated of use in Ecuadorian population. However, its concentration varies depending on several factors, therefore quality assessment need to be carried out through out several analytical methods. Aims: To validate an analytical method by high precision liquid chromatography (HPLC to quantify total isoflavones in herbal medicine. Methods: To quantify isoflavones, it was used a brand liquid chromatography with UV/VIS detector at 260 nm, C-18 column using isocratic method. The mobile phase was composed of 2% acetic acid: acetonitrile (75:25. The quantification was performed against reference standard. The parameters for the validation followed the established in the USP 33. Results: The chromatogram presented six peaks with elution between 1.557 and 18.913 min. The linearity of the system and the method got r2 equal to 0.98 and 0.99 respectively. The coefficients of variation 1.5% in the study of repetitiveness and 2% in intermediate precision. The accuracy of the adjusted lineal model exhibited r=0.95 and intercept reliable interval (-0.921; 1.743. Conclusions: The validated method was specific, accurate, precise and linear. It can be used for quality control and stability studies of isoflavones present in herbal medicine.

  6. Selective on-line detection of boronic acids and derivatives in high-performance liquid chromatography eluates by post-column reaction with alizarin

    NARCIS (Netherlands)

    Duval, F.L.; Wardani, P.A.; Zuilhof, H.; Beek, van T.A.

    2015-01-01

    An on-line high-performance liquid chromatography (HPLC) method for the rapid and selective detection of boronic acids in complex mixtures was developed. After optimization experiments at an HPLC flow rate of 0.40 mL/min, the HPLC-separated analytes were mixed post-column with a solution of 75 µM

  7. Flavonoid, hesperidine, total phenolic contents and antioxidant ...

    African Journals Online (AJOL)

    ONOS

    2010-01-11

    Jan 11, 2010 ... from citrus were mainly focused on its essential oils which include ... High performance liquid chromatography coupled to diode array detector ..... properties of xanthin on autoxidation of soybean oil in cyclodextrin emulsion.

  8. 4H-SiC Schottky diode arrays for X-ray detection

    Energy Technology Data Exchange (ETDEWEB)

    Lioliou, G. [Semiconductor Materials and Devices Laboratory, School of Engineering and Informatics, University of Sussex, Falmer, Brighton BN1 9QT (United Kingdom); Chan, H.K. [School of Electrical and Electronic Engineering, Newcastle University, Newcastle upon Tyne NE1 7RU (United Kingdom); Gohil, T. [Semiconductor Materials and Devices Laboratory, School of Engineering and Informatics, University of Sussex, Falmer, Brighton BN1 9QT (United Kingdom); Vassilevski, K.V.; Wright, N.G.; Horsfall, A.B. [School of Electrical and Electronic Engineering, Newcastle University, Newcastle upon Tyne NE1 7RU (United Kingdom); Barnett, A.M. [Semiconductor Materials and Devices Laboratory, School of Engineering and Informatics, University of Sussex, Falmer, Brighton BN1 9QT (United Kingdom)

    2016-12-21

    Five SiC Schottky photodiodes for X-ray detection have been electrically characterized at room temperature. One representative diode was also electrically characterized over the temperature range 20°C to 140 °C. The performance at 30 °C of all five X-ray detectors, in both current mode and for photon counting X-ray spectroscopy was investigated. The diodes were fabricated in an array form such that they could be operated as either a 2×2 or 1×3 pixel array. Although the devices showed double barrier heights, high ideality factors and higher than expected leakage current at room temperature (12 nA/cm{sup 2} at an internal electric field of 105 kV/cm), they operated as spectroscopic photon counting soft X-ray detectors uncooled at 30 °C. The measured energy resolution (FWHM at 17.4 keV, Mo Kα) varied from 1.36 to 1.68 keV among different diodes.

  9. Separation of amino acids and antibiotics by narrow-bore and normal-bore high-performance liquid chromatography with pre-column derivatization.

    Science.gov (United States)

    Fiedler, H P; Plaga, A

    1987-01-16

    The selectivity, efficiency and lifetime of normal- and narrow-bore columns for high-performance liquid chromatography were investigated for the separation and quantification of amino acids and the amino acid-like antibiotics phosphinothricin and phosphinothricylalanylalanine in biological samples. These compounds were determined by an automated pre-column derivatization with o-phthalaldehyde-2-mercaptoethanol reagent and UV detection at 338 nm.

  10. The simple and sensitive measurement of malondialdehyde in selected specimens of biological origin and some feed by reversed phase high performance liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Czauderna, M.; Kowalczyk, J.; Marounek, Milan

    2011-01-01

    Roč. 879, č. 23 (2011), s. 2251-2258 ISSN 1570-0232 Institutional research plan: CEZ:AV0Z50450515 Keywords : Malondialdehyde * 2,4-Dinitrophenylhydrazine * High performance liquid chromatography Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.888, year: 2011

  11. Characterisation of uremic "Middle molecular"fractions by gas chromatography mass spectrometry, isotachophoresis, and liquid chromatography

    NARCIS (Netherlands)

    Schoots, A.C.; Mikkers, F.E.P.; Claessens, H.A.; Smet, de R.; Landschoot, van N.; Ringoir, S.M.G.

    1982-01-01

    Uremic ultrafiltrates (and normal serum, for comparison) were fractionated by means of gel filtration. The collected fractions were further investigated by combined analytical techniques: "high- performance" liquid chromatography, gas chromatography, mass spectrometry, and isotachophoresis.

  12. High-performance Liquid Chromatographic Ultraviolet Detection of Nilotinib in Human Plasma from Patients with Chronic Myelogenous Leukemia, and Comparison with Liquid Chromatography-Tandem Mass Spectrometry.

    Science.gov (United States)

    Nakahara, Ryosuke; Satho, Yuhki; Itoh, Hiroki

    2016-11-01

    A method for determining nilotinib concentration in human plasma is proposed using high-performance liquid chromatography and ultraviolet detection. Nilotinib and the internal standard dasatinib were separated using a mobile phase of 0.5% Na 2 PO 4 H 2 O (pH 2.5)-acetonitrile-methanol (55:25:20, v/v/v) on a Capcell Pak C18 MG II column (250 × 4.6 mm) at a flow rate of 1.0 ml/min, and ultraviolet measurement at 250 nm. The calibration curve exhibited linearity over the nilotinib concentration range of 50-2,500 ng/ml at 250 nm, with relative standard deviations (n = 5) of 7.1%, 2.5%, and 2.9% for 250, 1,500, and 2,500 ng/ml, respectively. The detection limit for nilotinib was 5 ng/ml due to three blank determinations (ρ = 3). This method was successfully applied to assaying nilotinib in human plasma samples from patients with chronic myelogenous leukemia. In addition, we compared the results with those measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) at BML, Inc. (a commercial laboratory). A strong correlation was observed between the nilotinib concentrations measured by our high-performance liquid chromatographic method and those obtained by LC/MS-MS (r 2 = 0.988, P < 0.01). © 2016 Wiley Periodicals, Inc.

  13. Analysis of aromatic amines in water samples by liquid-liquid-liquid microextraction with hollow fibers and high-performance liquid chromatography.

    Science.gov (United States)

    Zhao, Limian; Zhu, Lingyan; Lee, Hian Kee

    2002-07-19

    Liquid-liquid-liquid microextraction (LLLME) with hollow fibers in high-performance liquid chromatography (HPLC) has been applied as a rapid and sensitive quantitative method for the detection of four aromatic amines (3-nitroaniline, 4-chloroaniline, 4-bromoaniline and 3,4-dichloroaniline) in environmental water samples. The preconcentration procedure was induced by the pH difference inside and outside the hollow fiber. The target compounds were extracted from 4-ml aqueous sample (donor solution, pH approximately 13) through a microfilm of organic solvent (di-n-hexyl ether), immobilized in the pores of a hollow fiber (1.5 cm length x 0.6 mm I.D.), and finally into 4 microl of acid acceptor solution inside the fiber. After a prescribed period of time, the acceptor solution inside the fiber was withdrawn into the microsyringe and directly injected into the HPLC system for analysis. Factors relevant to the extraction procedure were studied. Up to 500-fold enrichment of analytes could be obtained under the optimized conditions (donor solution: 0.1 M sodium hydroxide solution with 20% sodium chloride and 2% acetone; organic phase: di-n-hexyl ether; acceptor solution: 0.5 M hydrochloric acid and 500 mM 18-crown-6 ether; extraction time of 30 min; stirring at 1,000 rev./min). The procedure also served as a sample clean-up step. The influence of humic acid on the extraction efficiency was also investigated, and more than 85% relative recoveries of the analytes at two different concentrations (20 and 100 microg/l) were achieved at various concentration of humic acid. This technique is a low cost, simple and fast approach to the analysis of polar compounds in aqueous samples.

  14. Separation and preparation of xanthochymol and guttiferone E by high performance liquid chromatography and high speed counter-current chromatography combined with silver nitrate coordination reaction.

    Science.gov (United States)

    Li, Jun; Gao, Ruixi; Zhao, Dan; Huang, Xianju; Chen, Yu; Gan, Fei; Liu, Hui; Yang, Guangzhong

    2017-08-18

    Xanthochymol (XCM) and guttiferone E (GFE), a pair of π bond benzophenone isomers from Garcinia xanthochymus, were once reported to be difficult or impossible to separate. The present study reports the successful separation of these two isomers through high performance liquid chromatography (HPLC), as well as their effective isolation using high speed counter-current chromatography (HSCCC) based on the silver nitrate (AgNO 3 ) coordination reaction. First, an effective HPLC separation system was developed, achieving a successful baseline separation with resolution of 2.0. Based on the partition coefficient (K) resolved by HPLC, the two-phase solvent system was determined as n-hexane, methanol and water with the uncommon volume ratio of 4:6:1. A crude extract of Garcinia xanthochymus (0.2g) was purified by normal HSCCC and refined with AgNO 3 -HSCCC. Monomers of XCM and GFE were identified by HPLC, mass spectrometry (MS) and nuclear magnetic resonance (NMR). The results demonstrate the separation and isolation of π bond benzophenone isomers using ordinary octadecyl silane (C 18 ) columns and HSCCC. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Blind column selection protocol for two-dimensional high performance liquid chromatography.

    Science.gov (United States)

    Burns, Niki K; Andrighetto, Luke M; Conlan, Xavier A; Purcell, Stuart D; Barnett, Neil W; Denning, Jacquie; Francis, Paul S; Stevenson, Paul G

    2016-07-01

    The selection of two orthogonal columns for two-dimensional high performance liquid chromatography (LC×LC) separation of natural product extracts can be a labour intensive and time consuming process and in many cases is an entirely trial-and-error approach. This paper introduces a blind optimisation method for column selection of a black box of constituent components. A data processing pipeline, created in the open source application OpenMS®, was developed to map the components within the mixture of equal mass across a library of HPLC columns; LC×LC separation space utilisation was compared by measuring the fractional surface coverage, fcoverage. It was found that for a test mixture from an opium poppy (Papaver somniferum) extract, the combination of diphenyl and C18 stationary phases provided a predicted fcoverage of 0.48 and was matched with an actual usage of 0.43. OpenMS®, in conjunction with algorithms designed in house, have allowed for a significantly quicker selection of two orthogonal columns, which have been optimised for a LC×LC separation of crude extractions of plant material. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Determination of catechin in lotus rhizomes by high-performance liquid chromatography.

    Science.gov (United States)

    Yan, Shou-Lei; Wang, Qing-Zhang; Peng, Guang-Hua

    2009-08-01

    A novel method was developed to analyze lotus rhizome polyphenolic catechin using high-performance liquid chromatography (HPLC). The retain time of catechin was 14.72 min under the optimized condition. Mass spectrometry was further employed to qualify and quantify the purity of the catechin peak. Good linearity (R=0.9997) was obtained within the range of 50-1,000 ng. The coefficient of variance was determined as 5.2%, with a recovery rate of 97%. The detection and quantification limitations of catechin were 23 ng and 50 ng, respectively. The catechin level was 0.0025% in the lotus rhizome, and 0.011% in the knot of the lotus rhizome (Nelumbo nucifera cv. 'damao jie'). The optimized conditions of HPLC for catechin detection in the lotus rhizome matrix were as follows: the SuperlcosIL™ LC-18 analytical column (150 mm×4.6 mm, 5 µm), methanol-water-acetic acid (10:90:1, volume ratio) as the mobile phase, an UV detector at 280 nm, a flow rate of 0.8 ml/min, column temperature at 30°C, and an injection volume of 10 µl.

  17. Phytochemical Profile of Erythrina variegata by Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectroscopy Analyses.

    Science.gov (United States)

    Muthukrishnan, Suriyavathana; Palanisamy, Subha; Subramanian, Senthilkumar; Selvaraj, Sumathi; Mari, Kavitha Rani; Kuppulingam, Ramalingam

    2016-08-01

    Natural products derived from plant sources have been utilized to treat patients with numerous diseases. The phytochemical constituents present in ethanolic leaf extract of Erythrina variegata (ELEV) were identified by using high-performance liquid chromatography (HPLC) and gas chromatography-mass spectroscopy (GC-MS) analyses. Shade dried leaves were powdered and extracted with ethanol for analyses through HPLC to identify selected flavonoids and through GC-MS to identify other molecules. The HPLC analysis of ELEV showed the presence of gallic and caffeic acids as the major components at concentrations of 2.0 ppm and 0.1 ppm, respectively, as well as other components. GC-MS analysis revealed the presence of 3-eicosyne; 3,7,11,15-tetramethyl-2-hexadecen-1-ol; butanoic acid, 3-methyl-3,7-dimethyl-6-octenyl ester; phytol; 1,2-benzenedicarboxylic acid, diundecyl ester; 1-octanol, 2-butyl-; squalene; and 2H-pyran, 2-(7-heptadecynyloxy) tetrahydro-derivative. Because pharmacopuncture is a new evolving natural mode that uses herbal extracts for treating patients with various ailments with minimum pain and maximum effect, the results of this study are particularly important and show that ELEV possesses a wide range of phytochemical constituents, as indicated above, as effective active principle molecules that can be used individually or in combination to treat patients with various diseases. Copyright © 2016. Published by Elsevier B.V.

  18. Coupling liquid chromatography/mass spectrometry detection with microfluidic droplet array for label-free enzyme inhibition assay.

    Science.gov (United States)

    Wang, Xiu-Li; Zhu, Ying; Fang, Qun

    2014-01-07

    In this work, the combination of droplet-based microfluidics with liquid chromatography/mass spectrometry (LC/MS) was achieved, for providing a fast separation and high-information-content detection method for the analysis of nanoliter-scale droplets with complex compositions. A novel interface method was developed using an oil-covered droplet array chip to couple with an LC/MS system via a capillary sampling probe and a 4 nL injection valve without the need of a droplet extraction device. The present system can perform multistep operations including parallel enzyme inhibition reactions in nanoliter droplets, 4 nL sample injection, fast separation with capillary LC, and label-free detection with ESI-MS, and has significant flexibility in the accurate addressing and sampling of droplets of interest on demand. The system performance was evaluated using angiotensin I and angiotensin II as model samples, and the repeatabilities of peak area for angiotensin I and angiotensin II were 2.7% and 7.5% (RSD, n = 4), respectively. The present system was further applied to the screening for inhibitors of cytochrome P450 (CYP1A2) and measurement of the IC50 value of the inhibitor. The sample consumption for each droplet assay was 100 nL, which is reduced 10-100 times compared with conventional 384-multi-well plate systems usually used in high-throughput drug screening.

  19. [Determination of aspirin and free salicylic acid in lysinipirine injection by high performance liquid chromatography].

    Science.gov (United States)

    Dong, Yu; Zhao, Yuan-zheng; Zhang, Yi-na

    2002-05-01

    The contents of aspirin and free salicylic acid in lysinipirine injection were determined by high performance liquid chromatography (HPLC). A Hypersil BDS C18 column was used with the mobile phase of methanol-water-acetic acid (35:65:3, volume ratio) and the detection wavelength of 280 nm. The average recoveries of aspirin and salicylic acid added were 99.27% (RSD = 0.8%) and 99.61%(RSD = 1.3%), respectively. The calibration curves had good linearity in the range of 0.028 g/L -0.141 mg/L and 0.77 mg/L -3.85 mg/L, and the correlation coefficients were 0.9999 and 0.9998 for aspirin and salicylic acid respectively.

  20. Determination of free urinary cortisol in cushing's syndrome using reversed-phase high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Eduardo Kinio Sugawara

    2010-01-01

    Full Text Available Determination of free urinary cortisol is a test of choice in the diagnosis of Cushing's syndrome. In this study, cortisol was quantified using reversed-phase high-performance liquid chromatography (RP-HPLC in urine samples previously extracted with ether and using triamcinolone acetonide as internal standard (IS. A BDS-Hypersil-C18® column, water-acetonitrile (72:28; v/v, with a flow rate of 1.0 mL/min and detection at 243 nm were used. This method showed to be both effective and efficient, with sensitivity and linearity ranging from 2.50 to 150 μg/L, and can be used in substitution to the radioimmunoassay technique within this concentration range.

  1. Isolation and purification of six iridoid glycosides from gardenia jasminoides fruit by medium-pressure liquid chromatography combined with macroporous resin chromatography.

    Science.gov (United States)

    Wang, Yun; Liu, Hui; Shen, Lifeng; Yao, Lan; Ma, Yinlian; Yu, Dingrong; Chen, Jianhong; Li, Puling; Chen, Ying; Zhang, Cun

    2015-12-01

    Gardeniae fructus is one of the most frequently used herbs in traditional Chinese medicine. In the present study, a process for the enrichment of six iridoid glycosides from Gardeniae fructus was developed using medium-pressure liquid chromatography combined with macroporous resin and reversed-phase chromatography. The purities of different fractions from Gardeniae fructus were assessed using quantitative high-performance liquid chromatography. After fractionation using HPD-100 column chromatography, a 30% ethanol fraction was selected based on high-performance liquid chromatography and liquid chromatography with mass spectrometry qualitative analysis to separate and purify. Based on the orientation analysis results, six compounds-deacetyl asperulosidic acid methyl ester, gardenoside, ixoroside, scandoside methyl ester, genipin-1-O-β-d-gentiobioside, and geniposide-were successfully isolated and purified in three to four combined steps from Gardeniae fructus. The purities of these compounds were found by high-performance liquid chromatography analysis to be 97.9, 98.1, 95.5, 96.3, 97.1, and 98.7%, respectively. Moreover, their structures were elucidated by NMR spectroscopy and liquid chromatography with tandem mass spectrometry. The separation process was highly efficient, rapid, and accurate, making it a potential approach for the large-scale production of iridoids in the laboratory and providing several marker compounds for quality control. This procedure may be meaningful for the purification of other natural products used in traditional Chinese medicine. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Determination of 6-mercaptopurine and azathioprine in plasma by high-performance liquid chromatography.

    Science.gov (United States)

    Ding, T L; Benet, L Z

    1979-07-21

    Using 1-ml plasma samples, levels of 6-mercaptopurine (6MP) as low as 5 ng/ml and azathioprine (AZA) as low as 40 ng/ml can be detected using a high-performance liquid chromatography reversed-phase column procedure following extraction. Both compounds were stable in frozen plasma for seven weeks. AZA stability in blood was temperature dependent; the half-lives of AZA breakdown to 6MP at 37 degrees were 28 and 46 min in blood drawn from two rhesus monkeys. Plasma levels of 6MP were measured in a rhesus monkey following 6MP (1.47 mg/kg) and AZA (3 mg/kg) intravenous administration. 6MP levels were also measured in three renal transplant patients on daily 50- and 100-mg AZA doses. Peak levels (45-75 ng/ml) were reached within an hour and 6MP levels were detected for up to 7 h.

  3. Determination of five antiarrhythmic drugs in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Jouyban, Abolghasem; Sorouraddin, Mohammad Hossein; Farajzadeh, Mir Ali; Somi, Mohammad Hossein; Fazeli-Bakhtiyari, Rana

    2015-03-01

    A fast and sensitive high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for the simultaneous quantitation of five antiarrhythmic drugs (metoprolol, propranolol, carvedilol, diltiazem, and verapamil) in human plasma samples. It involves dispersive liquid-liquid microextraction (DLLME) of the desired drugs from 660 µL plasma and separation using isocratic elution with UV detection at 200 nm. The complete separation of all analytes was achieved within 7 min. Acetonitrile (as disperser solvent) resulting from the protein precipitation procedure was mixed with 100 µL dichloromethane (as an extraction solvent) and rapidly injected into 5 mL aqueous solution (pH 11.5) containing 1% (w/v), NaCl. After centrifugation, the sedimented phase containing enriched analytes was collected and evaporated to dryness. The residue was re-dissolved in 50 µL de-ionized water (acidified to pH 3) and injected into the HPLC system for analysis. Under the optimal conditions, the enrichment factors and extraction recoveries ranged between 4.4-10.8 and 33-82%, respectively. The suggested method was linear (r(2) ≥0.997) over a dynamic range of 0.02-0.80 µg mL(-1) in plasma. The intra- and inter-days relative standard deviation (RSD%) and relative error (RE%) values of the method were below 20%, which shows good precision and accuracy. Finally, this method was applied to the analysis of real plasma samples obtained from the patients treated with these drugs. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Air-assisted liquid-liquid microextraction integrated with QuEChERS for determining endocrine-disrupting compounds in fish by high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Luo, Zhoufei; Lu, Jing; Li, Haipu; Tu, Yi; Wan, Yuehao; Yang, Zhaoguang

    2018-09-15

    A new, sensitive, and rapid method based on the Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) approach and air-assisted liquid-liquid microextraction (AALLME) technology was developed for the determination of 20 endocrine-disrupting compounds (EDCs) in fish by high-performance liquid chromatography-tandem mass spectrometry. The method first integrates AALLME into QuEChERS to achieve clean-up and enrichment of the EDCs in one step. A self-made glass tube was enfolded with plasticine to withstand the high centrifugal force. The established method was developed by optimization of the parameters. High linearities (R 2  > 0.9924) and recoveries (78.2-118.6%) at three spiked levels (5, 10, and 20 ng g -1 ), and low relative standard deviation values (1.1-14.5%) and limits of detection (0.03-0.80 ng g -1 ) were obtained. The method comparison shows that the proposed method is superior as it involves less organic solvent usage, simple operation and high efficiency. This method was successfully applied to different fishes for analyzing EDCs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. Separation of anionic oligosaccharides by high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Green, E.D.; Baenziger, J.U.

    1986-01-01

    The authors have developed methods for rapid fractionation of anionic oligosaccharides containing sulfate and/or sialic acid moieties by high-performance liquid chromatography (HPLC). Ion-exchange HPLC on amine-bearing columns (Micropak AX-10 and AX-5) at pH 4.0 is utilized to separate anionic oligosaccharides bearing zero, one, two, three, or four charges, independent of the identity of the anionic moieties (sulfate and/or sialic acid). Ion-exchange HPLC at pH 1.7 allows separation of neutral, mono-, di-, and tetrasialylated, monosulfated, and disulfated oligosaccharides. Oligosaccharides containing three sialic acid residues and those bearing one each of sulfate and sialic acid, however, coelute at pH 1.7. Since the latter two oligosaccharide species separate at pH 4.0, analysis at pH 4.0 followed by analysis at pH 1.7 can be utilized to completely fractionate complex mixtures of sulfated and sialylated oligosaccharides. Ion-suppression amine adsorption HPLC has previously been shown to separate anionic oligosaccharides on the basis of net carbohydrate content (size). In this study they demonstrate the utility of ion-suppression amine adsorption HPLC for resolving sialylated oligosaccharide isomers which differ only in the linkages of sialic acid residues (α2,3 vs α2,6) and/or location of α2,3- and α2,6-linked sialic acid moieties on the peripheral branches of oligosaccharides. These two methods can be used in tandem to separate oligosaccharides, both analytically and preparatively, based on their number, types, and linkages of anionic moieties

  6. Determination of flavonoids in cultivated sugarcane leaves, bagasse, juice and in transgenic sugarcane by liquid chromatography-UV detection.

    Science.gov (United States)

    Colombo, Renata; Lanças, Fernando M; Yariwake, Janete H

    2006-01-20

    A high-performance liquid chromatography (HPLC) method with photo-diode array (DAD) detection was developed to separate and quantify flavonoids in sugarcane leaves and bagasse (= the crushed sugarcane refuse from juice extraction), and in sugarcane juice. Sugarcane flavonoids consist of a complex mixture of aglycones and glycosides (including flavonolignan glycosides), and the HPLC-UV method herein proposed is suitable for their quantification as total flavonoids. This method was applied to analyze samples of cultivated sugarcane, commercial juice and transgenic sugarcane leaves. Sugarcane leaves proved a promising source of flavonoids: an average of 1.10 mg of total flavonoids/g plant material was found in fresh leaves. Moreover, the flavonoid content of sugarcane juice (0.6 mg/mL) is comparable to other food sources of flavonoids previously reported. Transgenic sugarcane leaves ("Bowman-Birk" and "Kunitz") were compared with non-modified ("control") plant samples using the proposed HPLC-UV method, which indicated that the content of total flavonoids in transgenic plants is different from that in non-modified sugarcane.

  7. Preconcentration and determination of ceftazidime in real samples using dispersive liquid-liquid microextraction and high-performance liquid chromatography with the aid of experimental design.

    Science.gov (United States)

    Razmi, Rasoul; Shahpari, Behrouz; Pourbasheer, Eslam; Boustanifar, Mohammad Hasan; Azari, Zhila; Ebadi, Amin

    2016-11-01

    A rapid and simple method for the extraction and preconcentration of ceftazidime in aqueous samples has been developed using dispersive liquid-liquid microextraction followed by high-performance liquid chromatography analysis. The extraction parameters, such as the volume of extraction solvent and disperser solvent, salt effect, sample volume, centrifuge rate, centrifuge time, extraction time, and temperature in the dispersive liquid-liquid microextraction process, were studied and optimized with the experimental design methods. Firstly, for the preliminary screening of the parameters the taguchi design was used and then, the fractional factorial design was used for significant factors optimization. At the optimum conditions, the calibration curves for ceftazidime indicated good linearity over the range of 0.001-10 μg/mL with correlation coefficients higher than the 0.98, and the limits of detection were 0.13 and 0.17 ng/mL, for water and urine samples, respectively. The proposed method successfully employed to determine ceftazidime in water and urine samples and good agreement between the experimental data and predictive values has been achieved. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Determination of La and Nd by thermal ionization mass spectrometry (TIMS) pre-separated by high performance liquid chromatography (HPLC)

    International Nuclear Information System (INIS)

    Jaison, P.G.; Raut, N.M.; Parab, A.R.; Khodade, P.S.; Govindan, R.; Aggarwal, S.K.

    2003-01-01

    Determination of La and Nd by TIMS is required for accurate determination of burn-up of nuclear fuels. During their thermal ionization mass spectrometric (TIMS) analysis, 138 Ce and 142 Ce show spectroscopic isobaric interferences at 138 La and 142 Nd, respectively. Hence, it is essential to remove Ce from La and Nd for their accurate isotopic composition determination. Reversed phase high performance liquid chromatography (HPLC) is a promising technique for rapid and effective separation

  9. Combination of saponification and dispersive liquid-liquid microextraction for the determination of tocopherols and tocotrienols in cereals by reversed-phase high-performance liquid chromatography.

    Science.gov (United States)

    Shammugasamy, Balakrishnan; Ramakrishnan, Yogeshini; Ghazali, Hasanah M; Muhammad, Kharidah

    2013-07-26

    A simple sample preparation technique coupled with reversed-phase high-performance liquid chromatography was developed for the determination of tocopherols and tocotrienols in cereals. The sample preparation procedure involved a small-scale hydrolysis of 0.5g cereal sample by saponification, followed by the extraction and concentration of tocopherols and tocotrienols from saponified extract using dispersive liquid-liquid microextraction (DLLME). Parameters affecting the DLLME performance were optimized to achieve the highest extraction efficiency and the performance of the developed DLLME method was evaluated. Good linearity was observed over the range assayed (0.031-4.0μg/mL) with regression coefficients greater than 0.9989 for all tocopherols and tocotrienols. Limits of detection and enrichment factors ranged from 0.01 to 0.11μg/mL and 50 to 73, respectively. Intra- and inter-day precision were lower than 8.9% and the recoveries were around 85.5-116.6% for all tocopherols and tocotrienols. The developed DLLME method was successfully applied to cereals: rice, barley, oat, wheat, corn and millet. This new sample preparation approach represents an inexpensive, rapid, simple and precise sample cleanup and concentration method for the determination of tocopherols and tocotrienols in cereals. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Speciation of mercury in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jia Xiaoyu; Han Yi; Liu Xinli [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China); Graduate School of Chinese Academy of Sciences, Beijing 100039 (China); Duan Taicheng, E-mail: tcduan@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China); Chen Hangting, E-mail: htchen@ciac.jl.cn [State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Science, Changchun 130022 (China)

    2011-01-15

    The dispersive liquid-liquid microextraction (DLLME) combined with high performance liquid chromatography-inductively coupled plasma mass spectrometry for the speciation of mercury in water samples was described. Firstly methylmercury (MeHg{sup +}) and mercury (Hg{sup 2+}) were complexed with sodium diethyldithiocarbamate, and then the complexes were extracted into carbon tetrachloride by using DLLME. Under the optimized conditions, the enrichment factors of 138 and 350 for MeHg{sup +} and Hg{sup 2+} were obtained from only 5.00 mL sample solution. The detection limits of the analytes (as Hg) were 0.0076 ng mL{sup -1} for MeHg{sup +} and 0.0014 ng mL{sup -1} for Hg{sup 2+}, respectively. The relative standard deviations for ten replicate measurements of 0.5 ng mL{sup -1} MeHg{sup +} and Hg{sup 2+} were 6.9% and 4.4%, respectively. Standard reference material of seawater (GBW(E)080042) was analyzed to verify the accuracy of the method and the results were in good agreement with the certified values. Finally, the developed method was successfully applied for the speciation of mercury in three environmental water samples.

  11. Comparative Study of Continuous Pralidoxime Infusion versus Intermittent Dosing: Application of High-Performance Liquid Chromatography Method on Serum of Organophosphate Poisoned Patients

    Directory of Open Access Journals (Sweden)

    Girish Thunga

    2013-09-01

    How to cite this article: Thunga G, Pandey S, Nair S, Mylapuri R, Vidyasagar S, Kunhikatta V, et al. Comparative Study of Continuous Pralidoxime Infusion versus Intermittent Dosing: Application of High-Performance Liquid Chromatography Method on Serum of Organophosphate Poisoned Patients. Asia Pac J Med Toxicol 2013;2:105-10.

  12. Improving Lifetime of Quasi-CW Laser Diode Arrays for Pumping 2-Micron Solid State Lasers

    Science.gov (United States)

    Amzajerdian, Farzin; Meadows, Byron L.; Baker, Nathaniel R.; Barnes, Bruce W.; Singh, Upendra N.; Kavaya, Michael J.

    2007-01-01

    Operating high power laser diode arrays in long pulse regime of about 1 msec, which is required for pumping 2-micron thulium and holmium-based lasers, greatly limits their useful lifetime. This paper describes performance of laser diode arrays operating in long pulse mode and presents experimental data on the active region temperature and pulse-to-pulse thermal cycling that are the primary cause of their premature failure and rapid degradation. This paper will then offer a viable approach for determining the optimum design and operational parameters leading to the maximum attainable lifetime.

  13. Analytical Method Validation of High-Performance Liquid Chromatography and Stability-Indicating Study of Medroxyprogesterone Acetate Intravaginal Sponges

    Directory of Open Access Journals (Sweden)

    Nidal Batrawi

    2017-02-01

    Full Text Available Medroxyprogesterone acetate is widely used in veterinary medicine as intravaginal dosage for the synchronization of breeding cycle in ewes and goats. The main goal of this study was to develop reverse-phase high-performance liquid chromatography method for the quantification of medroxyprogesterone acetate in veterinary vaginal sponges. A single high-performance liquid chromatography/UV isocratic run was used for the analytical assay of the active ingredient medroxyprogesterone. The chromatographic system consisted of a reverse-phase C18 column as the stationary phase and a mixture of 60% acetonitrile and 40% potassium dihydrogen phosphate buffer as the mobile phase; the pH was adjusted to 5.6. The method was validated according to the International Council for Harmonisation (ICH guidelines. Forced degradation studies were also performed to evaluate the stability-indicating properties and specificity of the method. Medroxyprogesterone was eluted at 5.9 minutes. The linearity of the method was confirmed in the range of 0.0576 to 0.1134 mg/mL ( R 2 > 0.999. The limit of quantification was shown to be 3.9 µg/mL. Precision and accuracy ranges were found to be %RSD <0.2 and 98% to 102%, respectively. Medroxyprogesterone capacity factor value of 2.1, tailing factor value of 1.03, and resolution value of 3.9 were obtained in accordance with ICH guidelines. Based on the obtained results, a rapid, precise, accurate, sensitive, and cost-effective analysis procedure was proposed for quantitative determination of medroxyprogesterone in vaginal sponges. This analytical method is the only available method to analyse medroxyprogesterone in veterinary intravaginal dosage form.

  14. Fundamental and practical studies on high-performance liquid affinity chromatography of biopolymers with novel stationary phases

    Energy Technology Data Exchange (ETDEWEB)

    Bacolod, M.D.

    1992-01-01

    Rigid microparticulate stationary phases having surface-bound metal chelating functions were developed and evaluated in high performance metal chelate affinity chromatography of proteins. Silica- and polystyrene-divinylbenzene-based metal chelate sorbents were produced in wide pore and in non-porous type of column packings. A major effort has been placed on development of non-porous highly crosslinked polystyrene-divinylbenzene (PSDVB). These PSDVB microparticles were produced by a two-step swelling polymerization, and exhibited excellent mechanical strength over a wide range of flow-rates and composition used in high performance liquid chromatography (HPLC). Simple and reproducible hydrophilic coatings were developed for the surface modification of hydrophobic PSDVB supports. A tetradentate metal chelating ligand, ethylenediamine-N, N[prime]-diacetic acid (EDDA), was covalently bound to the surface of the various supports. Sorbents having iminodiacetic acid (IDA) metal chelating functions were also evaluated. The hydrophilic character and surface coverage of various stationary phases were assessed chromatographically. Studies concerning the effects of eluent pH as well as the nature and concentration of salts on retention and selectivity with different metal chelate stationary phases having various immobilized metal ions were carried out. Elution schemes were developed for rapid separation of proteins in metal chelate affinity chromatography. EDDA stationary phases in metal forms can be viewed as complementary to IDA stationary phases since they afforded different selectivity and retentivity toward proteins. Hydrophilic PSDVB could be functionalized with IDA or EDDA metal chelating ligands or lectins. The non-porous metal chelate stationary phases afforded rapid separation of proteins by the development of multiple gradient systems, which permitted higher column peak capacity, enabling the separation of a greater number of proteins in a single chromatographic run.

  15. Supercritical Fluid Extraction and Ultra Performance Liquid Chromatography of Respiratory Quinones for Microbial Community Analysis in Environmental and Biological Samples

    Directory of Open Access Journals (Sweden)

    Koichi Fujie

    2012-03-01

    Full Text Available Microbial community structure plays a significant role in environmental assessment and animal health management. The development of a superior analytical strategy for the characterization of microbial community structure is an ongoing challenge. In this study, we developed an effective supercritical fluid extraction (SFE and ultra performance liquid chromatography (UPLC method for the analysis of bacterial respiratory quinones (RQ in environmental and biological samples. RQ profile analysis is one of the most widely used culture-independent tools for characterizing microbial community structure. A UPLC equipped with a photo diode array (PDA detector was successfully applied to the simultaneous determination of ubiquinones (UQ and menaquinones (MK without tedious pretreatment. Supercritical carbon dioxide (scCO2 extraction with the solid-phase cartridge trap proved to be a more effective and rapid method for extracting respiratory quinones, compared to a conventional organic solvent extraction method. This methodology leads to a successful analytical procedure that involves a significant reduction in the complexity and sample preparation time. Application of the optimized methodology to characterize microbial communities based on the RQ profile was demonstrated for a variety of environmental samples (activated sludge, digested sludge, and compost and biological samples (swine and Japanese quail feces.

  16. Computational design and fabrication of core-shell magnetic molecularly imprinted polymer for dispersive micro-solid-phase extraction coupled with high-performance liquid chromatography for the determination of rhodamine 6G.

    Science.gov (United States)

    Xie, Jin; Xie, Jie; Deng, Jian; Fang, Xiangfang; Zhao, Haiqing; Qian, Duo; Wang, Hongjuan

    2016-06-01

    A novel core-shell magnetic nano-adsorbent with surface molecularly imprinted polymer coating was fabricated and then applied to dispersive micro-solid-phase extraction followed by determination of rhodamine 6G using high-performance liquid chromatography. The molecularly imprinted polymer coating was prepared by copolymerization of dopamine and m-aminophenylboronic acid (functional monomers), in the presence of rhodamine 6G (template). The selection of the suitable functional monomers was based on the interaction between different monomers and the template using the density functional theory. The ratios of the monomers to template were further optimized by an OA9 (3(4) ) orthogonal array design. The binding performances of the adsorbent were evaluated by static, kinetic, and selective adsorption experiments. The results reveal that the adsorbent possesses remarkable affinity and binding specificity for rhodamine 6G because of the enhanced Lewis acid-base interaction between the B(Ш) embedded in the imprinted cavities and the template. The nano-adsorbent was successfully applied to dispersive micro-solid-phase extraction coupled to high-performance liquid chromatography for the trace determination of rhodamine 6G in samples with a detection limit of 2.7 nmol/L. Spiked recoveries ranged from 93.0-99.1, 89.5-92.7, and 86.9-105% in river water, matrimony vine and paprika samples, respectively, with relative standard deviations of less than 4.3%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Simultaneous determination of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk by ultra-high performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Yuanyuan; Li, Xiaowei; Zhang, Zhiwen; Ding, Shuangyang; Jiang, Haiyang; Li, Jiancheng; Shen, Jianzhong; Xia, Xi

    2016-02-01

    A sensitive, confirmatory ultra-high performance liquid chromatography-tandem mass spectrometric method was developed and validated to detect 23 veterinary drugs and metabolites (nitroimidazoles, benzimidazoles, and chloramphenicol components) in bovine milk. Compounds of interest were sequentially extracted from milk with acetonitrile and basified acetonitrile using sodium chloride to induce liquid-liquid partition. The extract was purified on a mixed mode solid-phase extraction cartridge. Using rapid polarity switching in electrospray ionization, a single injection was capable of detecting both positively and negatively charged analytes in a 9 min chromatography run time. Recoveries based on matrix-matched calibrations and isotope labeled internal standards for milk ranged from 51.7% to 101.8%. The detection limits and quantitation limits of the analytical method were found to be within the range of 2-20 ng/kg and 5-50 ng/kg, respectively. The recommended method is simple, specific, and reliable for the routine monitoring of nitroimidazoles, benzimidazoles, and chloramphenicol components in bovine milk samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. A high-performance liquid chromatography-based radiometric assay for acyl-CoA:alcohol transacylase from jojoba.

    Science.gov (United States)

    Garver, W S; Kemp, J D; Kuehn, G D

    1992-12-01

    Acyl-CoA:alcohol transacylase catalyzes the final step in the biosynthesis of storage liquid wax esters from acyl-CoA fatty acids and fatty alcohols in a limited number of microbes, algae, and Simmondsia chinensis Link (jojoba). An improved and automated method of enzyme assay for this catalyst from cotyledons of jojoba is described. The assay method uses reversed-phase C18 high performance liquid chromatography (HPLC) to separate the labeled C30:1 liquid wax product, [14C]-dodecanyl-octadecenoate, from the unreacted substrate, [14C]octadecenoyl-CoA (oleyl-CoA), and other components produced from enzymes present in the crude homogenate of jojoba cotyledons, including [14C]-octadecenoic acid (oleic acid) and [14C]octadecenol (oleyol). Methods are also described for microscale chemical synthesis in one vessel of 14C-radiolabeled substrates and products for the transacylase. These labeled reagents are required to confirm the HPLC separations of reaction products. The radioactive components are quantitated using an on-line flow-through scintillation detector enabling sensitive and precise analysis of the reaction products.

  19. Analysis of patulin in dutch food, an evaluation of a SPE based method

    NARCIS (Netherlands)

    Boonzaaijer, G.; Bobeldijk, I.; Osenbruggen, W.A. van

    2005-01-01

    A reliable method for the determination of patulin in apple juice, apple puree and apples was developed using two clean-up steps and high performance liquid chromatography and diode array (HPLC-DAD) analysis. Baseline separation from hydroxymethyl furfural (HMF) was obtained. The performance

  20. Single laboratory validation of the determination of yohimbine in yohimbe bark and related dietary supplements using UHPLC/UV/MS

    Science.gov (United States)

    A single laboratory validation has been performed on a practical ultra high-performance liquid chromatography (UHPLC), diode array detection (DAD), and tandem mass spectrometry (MS) method for determination of yohimbine in yohimbe barks and related dietary supplements. Good separation was achieved u...

  1. Phytochemical analysis of ethanolic extract of Dichrostachys Cinerea W and Arn leaves by a thin layer chromatography, high performance thin layer chromatography and column chromatography

    OpenAIRE

    M Vijayalakshmi; K Periyanayagam; K Kavitha; K Akilandeshwari

    2013-01-01

    Background: The leaves of Dichrostachys cinerea are used as laxative, diuretic, painkiller. It is also used in the treatment of gonorrhoea, boils, oedema, gout, veneral diseases and nasopharyngeal affections, etc. Materials and Methods: The Phytochemical investigation of ethanolic extract of D. cinerea leaves were performed by standard chemical tests, thin layer chromatography (TLC) by using various solvent systems, and by high performance liquid chromatography (HPTLC). Two compounds were...

  2. High Performance Liquid Chromatography of Some Analgesic Compounds: An Instrumental Analysis Experiment.

    Science.gov (United States)

    Haddad, Paul; And Others

    1983-01-01

    Background information, procedures, and results are provided for an experiment demonstrating techniques of solvent selection, gradient elution, pH control, and ion-pairing in the analysis of an analgesic mixture using reversed-phase liquid chromatography on an octadecylsilane column. Although developed using sophisticated/expensive equipment, less…

  3. Separation properties of the MIL-125(Ti) Metal-Organic Framework in high-performance liquid chromatography revealing cis/trans selectivity.

    Science.gov (United States)

    Van der Perre, Stijn; Liekens, Anuschka; Bueken, Bart; De Vos, Dirk E; Baron, Gino V; Denayer, Joeri F M

    2016-10-21

    Monodisperse MIL-125(Ti) Metal-Organic Framework crystals were synthesized and studied as stationary phase in high performance liquid chromatography (HPLC). Different pure compounds and model mixtures (including stereoisomer mixtures) were injected from which chromatographic parameters, including selectivities and resolution factors, were determined to evaluate the adsorption properties and separation performance of MIL-125(Ti) in liquid phase. The MIL-125(Ti) framework displayed a trans selectivity for cis/trans difunctionalized cyclohexane molecules with high selectivity and resolution for 1,3-dimethylcyclohexane and 4-ethylcyclohexanol. The slurry-packed column was further characterized via van Deemter analysis. Fitting of the van Deemter equation through the experimental points allowed to define the contributions of the different processes to plate height with a significant proportion of the A-term, reflecting the importance of a good crystal packing. Although high in comparison to commercial HPLC stationary phases, a very good plate height of around 50μm was found. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Simultaneous determination of several phytohormones in natural coconut juice by hollow fiber-based liquid-liquid-liquid microextraction-high performance liquid chromatography.

    Science.gov (United States)

    Wu, Yunli; Hu, Bin

    2009-11-06

    A simple, selective, sensitive and inexpensive method of hollow fiber-based liquid-liquid-liquid microextraction (HF-LLLME) combined with high performance liquid chromatography (HPLC)-ultraviolet (UV) detection was developed for the determination of four acidic phytohormones (salicylic acid (SA), indole-3-acetic acid (IAA), (+/-) abscisic acid (ABA) and (+/-) jasmonic acid (JA)) in natural coconut juice. To the best of our knowledge, this is the first report on the use of liquid phase microextraction (LPME) as a sample pretreatment technique for the simultaneous analysis of several phytohormones. Using phenetole to fill the pores of hollow fiber as the organic phase, 0.1molL(-1) NaOH solution in the lumen of hollow fiber as the acceptor phase and 1molL(-1) HCl as the donor phase, a simultaneous preconcentration of four target phytohormones was realized. The acceptor phase was finally withdrawn into the microsyringe and directly injected into HPLC for the separation and quantification of the target phytohormones. The factors affecting the extraction efficiency of four phytohormones by HF-LLLME were optimized with orthogonal design experiment, and the data was analyzed by Statistical Product and Service Solutions (SPSS) software. Under the optimized conditions, the enrichment factors for SA, IAA, ABA and JA were 243, 215, 52 and 48, with the detection limits (S/N=3) of 4.6, 1.3, 0.9ngmL(-1) and 8.8 microg mL(-1), respectively. The relative standard deviations (RSDs, n=7) were 7.9, 4.9, 6.8% at 50ngmL(-1) level for SA, IAA, ABA and 8.4% at 500 microg mL(-1) for JA, respectively. To evaluate the accuracy of the method, the developed method was applied for the simultaneous analysis of several phytohormones in five natural coconut juice samples, and the recoveries for the spiked samples were in the range of 88.3-119.1%.

  5. Separation and quantitation of polyethylene glycols 400 and 3350 from human urine by high-performance liquid chromatography.

    Science.gov (United States)

    Ryan, C M; Yarmush, M L; Tompkins, R G

    1992-04-01

    Polyethylene glycol 3350 (PEG 3350) is useful as an orally administered probe to measure in vivo intestinal permeability to macromolecules. Previous methods to detect polyethylene glycol (PEG) excreted in the urine have been hampered by inherent inaccuracies associated with liquid-liquid extraction and turbidimetric analysis. For accurate quantitation by previous methods, radioactive labels were required. This paper describes a method to separate and quantitate PEG 3350 and PEG 400 in human urine that is independent of radioactive labels and is accurate in clinical practice. The method uses sized regenerated cellulose membranes and mixed ion-exchange resin for sample preparation and high-performance liquid chromatography with refractive index detection for analysis. The 24-h excretion for normal individuals after an oral dose of 40 g of PEG 3350 and 5 g of PEG 400 was 0.12 +/- 0.04% of the original dose of PEG 3350 and 26.3 +/- 5.1% of the original dose of PEG 400.

  6. Simultaneous determination of phenolic compounds in Equisetum palustre L. by ultra high performance liquid chromatography with tandem mass spectrometry combined with matrix solid-phase dispersion extraction.

    Science.gov (United States)

    Wei, Zuofu; Pan, Youzhi; Li, Lu; Huang, Yuyang; Qi, Xiaolin; Luo, Meng; Zu, Yuangang; Fu, Yujie

    2014-11-01

    A method based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with tandem mass spectrometry is presented for the extraction and determination of phenolic compounds in Equisetum palustre. This method combines the high efficiency of matrix solid-phase dispersion extraction and the rapidity, sensitivity, and accuracy of ultra high performance liquid chromatography with tandem mass spectrometry. The influential parameters of the matrix solid-phase dispersion extraction were investigated and optimized. The optimized conditions were as follows: silica gel was selected as dispersing sorbent, the ratio of silica gel to sample was selected to be 2:1 (400/200 mg), and 8 mL of 80% methanol was used as elution solvent. Furthermore, a fast and sensitive ultra high performance liquid chromatography with tandem mass spectrometry method was developed for the determination of nine phenolic compounds in E. palustre. This method was carried out within <6 min, and exhibited satisfactory linearity, precision, and recovery. Compared with ultrasound-assisted extraction, the proposed matrix solid-phase dispersion procedure possessed higher extraction efficiency, and was more convenient and time saving with reduced requirements on sample and solvent amounts. All these results suggest that the developed method represents an excellent alternative for the extraction and determination of active components in plant matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. High flux diode packaging using passive microscale liquid-vapor phase change

    Science.gov (United States)

    Bandhauer, Todd; Deri, Robert J.; Elmer, John W.; Kotovsky, Jack; Patra, Susant

    2017-09-19

    A laser diode package includes a heat pipe having a fluid chamber enclosed in part by a heat exchange wall for containing a fluid. Wicking channels in the fluid chamber is adapted to wick a liquid phase of the fluid from a condensing section of the heat pipe to an evaporating section of the heat exchanger, and a laser diode is connected to the heat exchange wall at the evaporating section of the heat exchanger so that heat produced by the laser diode is removed isothermally from the evaporating section to the condensing section by a liquid-to-vapor phase change of the fluid.

  8. Validation of a high performance liquid chromatography analysis for the determination of noradrenaline and adrenaline in human urine with an on-line sample purification

    DEFF Research Database (Denmark)

    Hansen, Åse Marie; Kristiansen, J; Nielsen, J L

    1999-01-01

    A high performance liquid chromatography (HPLC) method with fluorescence detection including an on-line purification was established for determination of catecholamines in human urine. The method was evaluated using samples of pooled urine spiked with catecholamines and validated for measurements...

  9. The art and science of forming packed analytical high-performance liquid chromatography columns.

    Science.gov (United States)

    Kirkland, J J; Destefano, J J

    2006-09-08

    Columns of packed particles still are the most popular devices for high-performance liquid chromatography (HPLC) separations because of their great utility, excellent performance and wide variety. However, the forming of packed beds for efficient, stable columns traditionally has been an art where the basics of how to form optimum beds generally was not well understood. The recent development of monolith rods was introduced in part to overcome the difficulty of producing stable beds of packing particles. However, these materials are less versatile than packed particle columns. Technology developments in recent years have produced a better understanding among those skilled in the practice of how to form optimized packed beds, and this has led to widely available, high-quality commercial columns. This presentation discusses the developments that led to the present state of column packing technology. Important steps in the packing of efficient, stable beds are described. The key step of selecting the best solvent for the slurry packing method is emphasized. Factors affecting the mechanical stability of packed columns also are discussed. The early art of packing columns now has evolved into a more scientific approach that allows the packing of good columns with a minimum of effort and time.

  10. Quantitative structure-retention relationships of pesticides in reversed-phase high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Aschi, Massimiliano; D'Archivio, Angelo Antonio; Maggi, Maria Anna; Mazzeo, Pietro; Ruggieri, Fabrizio

    2007-01-01

    In this paper, a quantitative structure-retention relationships (QSRR) method is employed to predict the retention behaviour of pesticides in reversed-phase high-performance liquid chromatography (HPLC). A six-parameter nonlinear model is developed by means of a feed-forward artificial neural network (ANN) with back-propagation learning rule. Accurate description of the retention factors of 26 compounds including commonly used insecticides, herbicides and fungicides and some metabolites is successfully achieved. In addition to the acetonitrile content, included to describe composition of the water-acetonitrile mobile phase, the octanol-water partition coefficient (from literature) and four quantum chemical descriptors are considered to account for the effect of solute structure on the retention. These are: the total dipole moment, the mean polarizability, the anisotropy of polarizability and a descriptor of hydrogen bonding ability based on the atomic charges on hydrogen bond donor and acceptor chemical functionalities. The proposed nonlinear QSRR model exhibits a high degree of correlation between observed and computed retention factors and a good predictive performance in wide range of mobile phase composition (40-65%, v/v acetonitrile) that supports its application for the prediction of the chromatographic behaviour of unknown pesticides. A multilinear regression model based on the same six descriptors shows a significantly worse predictive capability

  11. Quantitative structure-retention relationships of pesticides in reversed-phase high-performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Aschi, Massimiliano [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); D' Archivio, Angelo Antonio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)]. E-mail: darchivi@univaq.it; Maggi, Maria Anna [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); Mazzeo, Pietro [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy); Ruggieri, Fabrizio [Dipartimento di Chimica, Ingegneria Chimica e Materiali, Universita degli Studi di L' Aquila, Via Vetoio, 67010 Coppito, L' Aquila (Italy)

    2007-01-23

    In this paper, a quantitative structure-retention relationships (QSRR) method is employed to predict the retention behaviour of pesticides in reversed-phase high-performance liquid chromatography (HPLC). A six-parameter nonlinear model is developed by means of a feed-forward artificial neural network (ANN) with back-propagation learning rule. Accurate description of the retention factors of 26 compounds including commonly used insecticides, herbicides and fungicides and some metabolites is successfully achieved. In addition to the acetonitrile content, included to describe composition of the water-acetonitrile mobile phase, the octanol-water partition coefficient (from literature) and four quantum chemical descriptors are considered to account for the effect of solute structure on the retention. These are: the total dipole moment, the mean polarizability, the anisotropy of polarizability and a descriptor of hydrogen bonding ability based on the atomic charges on hydrogen bond donor and acceptor chemical functionalities. The proposed nonlinear QSRR model exhibits a high degree of correlation between observed and computed retention factors and a good predictive performance in wide range of mobile phase composition (40-65%, v/v acetonitrile) that supports its application for the prediction of the chromatographic behaviour of unknown pesticides. A multilinear regression model based on the same six descriptors shows a significantly worse predictive capability.

  12. Determination of Fusarium toxins in functional vegetable milks applying salting-out-assisted liquid-liquid extraction combined with ultra-high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Hamed, Ahmed M; Arroyo-Manzanares, Natalia; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2017-11-01

    Vegetable milks are considered as functional foods due to their physiological benefits. Although the consumption of these products has significantly increased, they have received little attention in legislation with regard to contaminants. However, they may contain mycotoxins resulting from the use of contaminated raw materials. In this work, ultra-high-performance liquid chromatography tandem mass spectrometry has been proposed for the determination of the most relevant Fusarium toxins (fumonisin B 1 and B 2 , HT-2 and T-2 toxins, zearalenone, deoxynivalenol and fusarenon-X) in different functional beverages based on cereals, legumes and seeds. Sample treatment consisted of a simple salting-out-assisted liquid-liquid extraction with no further clean-up. The method provided limits of quantification between 3.2 and 57.7 µg L -1 , recoveries above 80% and precision with RSD lower than 12%. The method was also applied for studying the occurrence of these mycotoxins in market samples of vegetable functional beverages and deoxynivalenol was found in three oat-based commercial drinks.

  13. Characterization of polyoxyethylene tallow amine surfactants in technical mixtures and glyphosate formulations using ultra-high performance liquid chromatography and triple quadrupole mass spectrometry

    Science.gov (United States)

    Tush, Daniel; Loftin, Keith A.; Meyer, Michael T.

    2013-01-01

    Little is known about the occurrence, fate, and effects of the ancillary additives in pesticide formulations. Polyoxyethylene tallow amine (POEA) is a non-ionic surfactant used in many glyphosate formulations, a widely applied herbicide both in agricultural and urban environments. POEA has not been previously well characterized, but has been shown to be toxic to various aquatic organisms. Characterization of technical mixtures using ultra-high performance liquid chromatography (UHPLC) and mass spectrometry shows POEA is a complex combination of homologs of different aliphatic moieties and ranges of ethoxylate units. Tandem mass spectrometry experiments indicate that POEA homologs generate no product ions readily suitable for quantitative analysis due to poor sensitivity. A comparison of multiple high performance liquid chromatography (HPLC) and UHPLC analytical columns indicates that the stationary phase is more important in column selection than other parameters for the separation of POEA. Analysis of several agricultural and household glyphosate formulations confirms that POEA is a common ingredient but ethoxylate distributions among formulations vary.

  14. Determination of vitamins D2 and D3 in selected food matrices by online high-performance liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS).

    Science.gov (United States)

    Nestola, Marco; Thellmann, Andrea

    2015-01-01

    An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.

  15. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. II. Temperature and pressure effects.

    Science.gov (United States)

    Åsberg, Dennis; Samuelsson, Jörgen; Leśko, Marek; Cavazzini, Alberto; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2015-07-03

    The importance of the generated temperature and pressure gradients in ultra-high-pressure liquid chromatography (UHPLC) are investigated and compared to high-pressure liquid chromatography (HPLC). The drug Omeprazole, together with three other model compounds (with different chemical characteristics, namely uncharged, positively and negatively charged) were used. Calculations of the complete temperature profile in the column at UHPLC conditions showed, in our experiments, a temperature difference between the inlet and outlet of 16 °C and a difference of 2 °C between the column center and the wall. Through van't Hoff plots, this information was used to single out the decrease in retention factor (k) solely due to the temperature gradient. The uncharged solute was least affected by temperature with a decrease in k of about 5% while for charged solutes the effect was more pronounced, with k decreases up to 14%. A pressure increase of 500 bar gave roughly 5% increase in k for the uncharged solute, while omeprazole and the other two charged solutes gave about 25, 20 and 15% increases in k, respectively. The stochastic model of chromatography was applied to estimate the dependence of the average number of adsorption/desorption events (n) and the average time spent by a molecule in the stationary phase (τs) on temperature and pressure on peak shape for the tailing, basic solute. Increasing the temperature yielded an increase in n and decrease in τs which resulted in less skew at high temperatures. With increasing pressure, the stochastic modeling gave interesting results for the basic solute showing that the skew of the peak increased with pressure. The conclusion is that pressure effects are more pronounced for both retention and peak shape than the temperature effects for the polar or charged compounds in our study. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Protective properties of wine products and the role of high performance liquid chromatography in the study of these properties

    International Nuclear Information System (INIS)

    Ulyanova, E V; Larionov, O G; Revina, A A; Andrievskaya, D V; Urusova, L M; Fenin, A A

    2013-01-01

    Data on the biologically active substances present in wines and wine products, the methods of their determination, and changes under chemical, radiation and other types of action are generalized. The role of high performance liquid chromatography in the studies of the protective properties of wines is demonstrated. Particular attention is devoted to problems of counterfeiting of wine products and the possibility to reveal it by using amperometric determination of the antioxidant activity. The bibliography includes 117 references

  17. Application and comparison of high-speed countercurrent chromatography and high performance liquid chromatography in preparative enantioseparation of α-substitution mandelic acids.

    Science.gov (United States)

    Tong, Shengqiang; Zhang, Hu; Shen, Mangmang; Ito, Yoichiro; Yan, Jizhong

    2015-04-01

    Preparative enantioseparations of α-cyclopentylmandelic acid and α-methylmandelic acid by high-speed countercurrent chromatography (HSCCC) and high performance liquid chromatography (HPLC) were compared using hydroxypropy-β-cyclodextrin (HP-β-CD) and sulfobutyl ether-β-cyclodextrin (SBE-β-CD) as the chiral mobile phase additives. In preparative HPLC the enantioseparation was achieved on the ODS C 18 reverse phase column with the mobile phase composed of a mixture of acetonitrile and 0.10 mol L -1 phosphate buffer at pH 2.68 containing 20 mmol L -1 HP-β-CD for α-cyclopentylmandelic acid and 20 mmol L -1 SBE-β-CD for α-methylmandelic acid. The maximum sample size for α-cyclopentylmandelic acid and α-methylmandelic acid was only about 10 mg and 5 mg, respectively. In preparative HSCCC the enantioseparations of these two racemates were performed with the two-phase solvent system composed of n -hexane-methyl tert. -butyl ether-0.1 molL -1 phosphate buffer solution at pH 2.67 containing 0.1 mol L -1 HP-β-CD for α-cyclopentylmandelic acid (8.5:1.5:10, v/v/v) and 0.1 mol L -1 SBE-β-CD for α-methylmandelic acid (3:7:10, v/v/v). Under the optimum separation conditions, total 250 mg of racemic α-cyclopentylmandelic acid could be completely enantioseparated by HSCCC with HP-β-CD as a chiral mobile phase additive in a single run, yielding 105-110 mg of enantiomers with 95-98% purity and 85-90% recovery. But, no complete enantioseparation of α-methylmandelic acid was achieved by preparative HSCCC with either of the chiral selectors due to their limited enantioselectivity. In this paper preparative enantioseparation by HSCCC and HPLC was compared from various aspects.

  18. [Determination of amitrole in agricultural products by high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Li, Li; Fu, Jian; Gao, Hongliang; Ren, Haitao; Lou, Xishan; Guan, Lihui

    2010-03-01

    A high performance liquid chromatography-tandem mass spectrometry method (HPLC-MS/MS) was developed for the analysis of amitrole residues in agricultural products. The samples were extracted by 25% acetone for wheat, fish, pork and liver samples, 1% acetic acid-25% acetone for maize and peanut samples, 1% acetic acid solution for honeysuckle, the powder of ginger, the powder of bunge prickly ash and tea leaves samples, 1% acetic acid solution-dichloromethane for apple, pineapple, spinach, carrot, perilla leaves samples, respectively, followed by liquid-liquid extraction with dichloromethane. The samples were then cleaned up by PCX or Envi-Carb solid-phase extraction cartridge. The amitrole was determined and confirmed by HPLC-MS/MS. The results showed a linear relationship in the range of 0.005 -0.1 mg/kg for amitrole. The correlation coefficient was 0.999 7. The average recoveries of amitrole in wheat, maize, peanut, pineapple, apple, carrot, spinach, pork, the powder of ginger, the powder of bunge prickly ash, perilla, liver, fish, honeysuckle and tea were 67.5% - 98.1%. The relative standard deviations (RSDs) were 1.0% - 9.8%. The limits of quantitation were 10 microg/kg for wheat, maize, peanut, pineapple, apple, carrot, spinach, pork, perilla, liver, fish, honeysuckle and 20 microg/kg for the powder of bunge prickly ash, the powder of ginger and tea, respectively. The method is simple, sensitive and accurate.

  19. UHPLC: The Greening Face of Liquid Chromatography.

    Science.gov (United States)

    Cielecka-Piontek, Judyta; Zalewski, Przemysław; Jelińska, Anna; Garbacki, Piotr

    2013-01-01

    Pharmaceutical analysis based on chromatographic separation is an important part of studies aimed at developing routine quality analysis of drugs. High-performance liquid chromatography (HPLC) is one of the main analytical techniques recommended for drug analysis. Although it meets many criteria vital for analysis, it is time-consuming and uses a relatively high amount of organic solvents compared to other analytical techniques. Recently, Ultra-high-performance liquid chromatography (UHPLC) has been frequently proposed as an alternative to HPLC, which means introducing an environment-friendly approach to drug analysis achieved by reducing the consumption of solvents. It also offers greater chromatographic resolution and higher sensitivity as well as requiring less time due to faster analysis. This review focuses on the basics of UHPLC, compares that technique with HPLC and discusses the possibilities of applying UHPLC for the analysis of different pharmaceuticals and biopharmaceuticals.

  20. Utilization of high performance liquid chromatography coupled to tandem mass spectrometry for characterization of 8-O-methylbostrycoidin production by species of the fungus Fusarium

    Science.gov (United States)

    The pigment, 8-O-methylbostrycoidin is a polyketide metabolite produced by multiple species of the fungus Fusarium that infects plant crops, including maize. A technique was developed for the analysis of 8-O-methylbostrycoidin by high performance liquid chromatography coupled to electrospray ionizat...