  1. High field superconducting magnets

    Science.gov (United States)

    Hait, Thomas P. (Inventor); Shirron, Peter J. (Inventor)

    2011-01-01

    A superconducting magnet includes an insulating layer disposed about the surface of a mandrel; a superconducting wire wound in adjacent turns about the mandrel to form the superconducting magnet, wherein the superconducting wire is in thermal communication with the mandrel, and the superconducting magnet has a field-to-current ratio equal to or greater than 1.1 Tesla per Ampere; a thermally conductive potting material configured to fill interstices between the adjacent turns, wherein the thermally conductive potting material and the superconducting wire provide a path for dissipation of heat; and a voltage limiting device disposed across each end of the superconducting wire, wherein the voltage limiting device is configured to prevent a voltage excursion across the superconducting wire during quench of the superconducting magnet.

  2. A high-field pulsed magnet system for x-ray scattering studies in Voigt geometry

    CERN Document Server

    Islam, Zahirul; Ruff, Jacob P C; Das, Ritesh K; Trakhtenberg, Emil; Nojiri, Hiroyuki; Narumi, Yasuo; Canfield, Paul C

    2011-01-01

    We present a new pulsed-magnet system that enables x-ray single-crystal diffraction in addition to powder and spectroscopic studies in Voigt geometry. The apparatus consists of a large-bore solenoid, cooled by liquid nitrogen. A second independent closed-cycle cryostat is used for cooling samples near liquid helium temperatures. Pulsed magnetic fields up to ~30 T with a minimum of ~6 ms in total duration are generated by discharging a 40 kJ capacitor bank into the magnet coil. The unique characteristic of this instrument is the preservation of maximum scattering angle (~23.6 deg.) through the magnet bore by virtue of a novel double-funnel insert. This instrument would facilitate x-ray diffraction and spectroscopic studies that are impractical, if not impossible, to perform using conventional split-pair magnets and offers a practical solution for preserving optical access in future higher-field pulsed magnets.

  3. High Field Magnetization Studies of Low Dimensional Heisenberg S = 1/2 Antiferromagnets

    Science.gov (United States)

    Landee, C. P.; Turnbull, M. M.

    1998-03-01

    The magnetization curves of a number of low dimensional S=1/2 Heisenberg antiferromagnets have been determined in fields up to 30 tesla at low temperatures at the National High Magnetic Fields Laboratory. Materials studied include a family of 1D materials, based upon Cu(pyrazine)(NO_3)_2, 2D magnets consisting of pyrazine-bridged copper layers, and several spin ladders with singlet ground states. All of the magnetization data show upward curvature and are well described by T = 0 calculations based upon finite cluster models(Bonner and Fisher, Phys. Rev. A135, 640 (1964); Yang and Mutter, NANL cond-mat/9610092.). Chemical substitution on the pyrazine rings permits the variation of exchange constants by more than 25 percent for the family of well isolated chains. The spin ladder systems consist of ferromagnetic dimers weakly connected by antiferromagnetic intradimer interactions. Field induced transitions are seen at fields of less than one tesla for each of the three compounds.

  4. High-temperature superconductors in high-field magnets

    NARCIS (Netherlands)

    Weijers, Hubertus Wilhelmus

    2009-01-01

    The properties of both BSCCO conductors and YBCO coated conductors and coils are studied to assess their applicability in high-field magnets. First, the magnetic field dependence of the critical current density in these HTS conductors is measured at 4.2 K in magnetic field conditions ranging from s

  5. Numerical study of the thermal behavior of an Nb3Sn high field magnet in He II

    Science.gov (United States)

    Pietrowicz, S.; Baudouy, B.

    2013-01-01

    The high field magnet (HFM) project, within the European project EuCARD, aims at constructing an Nb3Sn high field accelerator magnet, the Fresca 2 magnet. This magnet is to serve as a test bed for future high field magnets and to upgrade the vertical CERN cable test facility. Fresca 2 is a block coil type magnet designed to produce 13 T at 1.9 K. To calculate the temperature margin and the evolution of the temperature due to a quench event within the magnet, we developed a 3D model implemented in ANSYS-CFX® software. This model is an extension of the 2D simplified "two-fluid model" proposed by Kitamura et al. with conjugate heat transfer and Kapitza resistance. This model is derived from the original two-fluid model and consisted of a conventional continuity equation, a modified momentum equation for the total fluid and an energy equation including the Gorter-Mellink internal convection term modeling the turbulence regime. The paper presents the model, the numerical schemes, the assumptions taken for the calculations and the results of the simulation obtained for the temperature evolution due to AC losses and due to quench heating within the magnet structure.

  6. High-field magnetization in transuranium compound

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, K. [Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan) and KYOKUGEN, Osaka University, Osaka 560-8531 (Japan)]. E-mail: sugiyama@phys.sci.osaka-u.ac.jp; Nakashima, H. [Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Aoki, D. [Institute of Material Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Ikeda, S. [Institute of Material Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Haga, Y. [Advanced Science and Research Centerer, JAEA, Tokai, Ibaraki 319-1195 (Japan); Yamamoto, E. [Advanced Science and Research Centerer, JAEA, Tokai, Ibaraki 319-1195 (Japan); Nakamura, A. [Advanced Science and Research Centerer, JAEA, Tokai, Ibaraki 319-1195 (Japan); Homma, Y. [Institute of Material Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Shiokawa, Y. [Institute of Material Research, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Kindo, K. [Institite of Solid State Physics, University of Tokyo, Kashiwanoha 5-1-5, Kashiwa, Chiba 277-8581 (Japan); Hagiwara, M. [KYOKUGEN, Osaka University, Osaka 560-8531 (Japan); Onuki, Y. [Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Advanced Science and Research Centerer, JAEA, Tokai, Ibaraki 319-1195 (Japan)

    2007-03-15

    We measured the high-field magnetization up to 55T and constructed a magnetic phase diagram for a transuranium antiferromagnet NpRhGa{sub 5} with the tetragonal structure. The magnetization at 4.2K for H(parallel) [100] indicates a sharp metamagnetic transition with a step at H{sub c}=26T and saturates above H{sub s}=38T, reaching 0.43{mu}{sub B}/Np. An ordered moment of 0.96{mu}{sub B}/Np at zero field, which was determined from the neutron scattering experiment, is found to be reduced to 0.43{mu}{sub B}/Np at H{sub s}, together with an orientation of the magnetic moment from the (001) plane to the (100) plane.

  7. A portable high-field pulsed-magnet system for single-crystal x-ray scattering studies.

    Science.gov (United States)

    Islam, Zahirul; Ruff, Jacob P C; Nojiri, Hiroyuki; Matsuda, Yasuhiro H; Ross, Kathryn A; Gaulin, Bruce D; Qu, Zhe; Lang, Jonathan C

    2009-11-01

    We present a portable pulsed-magnet system for x-ray studies of materials in high magnetic fields (up to 30 T). The apparatus consists of a split-pair of minicoils cooled on a closed-cycle cryostat, which is used for x-ray diffraction studies with applied field normal to the scattering plane. A second independent closed-cycle cryostat is used for cooling the sample to near liquid helium temperatures. Pulsed magnetic fields (approximately 1 ms in total duration) are generated by discharging a configurable capacitor bank into the magnet coils. Time-resolved scattering data are collected using a combination of a fast single-photon counting detector, a multichannel scaler, and a high-resolution digital storage oscilloscope. The capabilities of this instrument are used to study a geometrically frustrated system revealing strong magnetostrictive effects in the spin-liquid state.

  8. High Field Pulse Magnets with New Materials

    Science.gov (United States)

    Li, L.; Lesch, B.; Cochran, V. G.; Eyssa, Y.; Tozer, S.; Mielke, C. H.; Rickel, D.; van Sciver, S. W.; Schneider-Muntau, H. J.

    2004-11-01

    High performance pulse magnets using the combination of CuNb conductor and Zylon fiber composite reinforcement with bore sizes of 24, 15 and 10 mm have been designed, manufactured and tested to destruction. The magnets successfully reached the peak fields of 64, 70 and 77.8 T respectively with no destruction. Failures occurred near the end flanges at the layer. The magnet design, manufacturing and testing, and the mode of the failure are described and analyzed.

  9. High Field Magnetization of Tb Single Crystals

    DEFF Research Database (Denmark)

    Roeland, L. W.; Cock, G. J.; Lindgård, Per-Anker

    1975-01-01

    The magnetization of Tb single crystals was measured in magnetic fields to 34T along the hard direction at temperature of 1.8, 4.2, 65.5 and 77K, and along with easy direction at 4.2 and 77K. The data are compared with the results of a self-consistent spin wave calculation using a phenomenological...

  10. High-Field Superconducting Magnets Supporting PTOLEMY

    Science.gov (United States)

    Hopkins, Ann; Luo, Audrey; Osherson, Benjamin; Gentile, Charles; Tully, Chris; Cohen, Adam

    2013-10-01

    The Princeton Tritium Observatory for Light, Early Universe, Massive Neutrino Yield (PTOLEMY) is an experiment planned to collect data on Big Bang relic neutrinos, which are predicted to be amongst the oldest and smallest particles in the universe. Currently, a proof-of-principle prototype is being developed at Princeton Plasma Physics Laboratory to test key technologies associated with the experiment. A prominent technology in the experiment is the Magnetic Adiabatic Collimation with an Electrostatic Filter (MAC-E filter), which guides tritium betas along magnetic field lines generated by superconducting magnets while deflecting those of lower energies. B field mapping is performed to ensure the magnets produce a minimum field at the midpoint of the configuration of the magnets and to verify accuracy of existing models. Preliminary tests indicate the required rapid decrease in B field strength from the bore of the more powerful 3.35 T magnet, with the field dropping to 0.18 T approximately 0.5 feet from the outermost surface of the magnet.

  11. High-Field Accelerator Magnets Beyond LHC

    CERN Document Server

    Devred, Arnaud

    2003-01-01

    The LHC magnet R&D Program has shown that the limit of NbTi technology at 1.8 K was in the range 10 to 10.5 T. Hence, to go beyond the 10-T threshold, it is necessary to change of superconducting material. Given the state of the art in HTS, the only serious candidate is Nb3Sn. A series of dipole magnet models built at Twente University and LBNL and a vigorous program underway at FNAL have demonstrated the feasibility of Nb3Sn magnet technology. The next step is to bring this technology to maturity, which requires further conductor and conductor insulation development and a simplification of manufacturing processes. After outlining a roadmap to address outstanding issues, we evoke the US proposal for a second generation of LHC Insertion Region (IR) magnets and the Next European Dipole (NED) initiative promoted by the European Steering Group on Accelerator R&D (ESGARD).

  12. Magnetic resonance imaging and spectroscopy at ultra high fields

    Energy Technology Data Exchange (ETDEWEB)

    Neuberger, Thomas

    2009-06-23

    The goal of the work presented in this thesis was to explore the possibilities and limitations of MRI / MRS using an ultra high field of 17.6 tesla. A broad range of specific applications and MR methods, from MRI to MRSI and MRS were investigated. The main foci were on sodium magnetic resonance spectroscopic imaging of rodents, magnetic resonance spectroscopy of the mouse brain, and the detection of small amounts of iron labeled stem cells in the rat brain using MRI Sodium spectroscopic imaging was explored since it benefits tremendously from the high magnetic field. Due to the intrinsically low signal in vivo, originating from the low concentrations and short transverse relaxation times, only limited results have been achieved by other researchers until now. Results in the literature include studies conducted on large animals such as dogs to animals as small as rats. No studies performed on mice have been reported, despite the fact that the mouse is the most important laboratory animal due to the ready availability of transgenic strains. Hence, this study concentrated on sodium MRSI of small rodents, mostly mice (brain, heart, and kidney), and in the case of the brain on young rats. The second part of this work concentrated on proton magnetic resonance spectroscopy of the rodent brain. Due to the high magnetic field strength not only the increasing signal but also the extended spectral resolution was advantageous for such kind of studies. The difficulties/limitations of ultra high field MRS were also investigated. In the last part of the presented work detection limits of iron labeled stem cells in vivo using magnetic resonance imaging were explored. The studies provided very useful benchmarks for future researchers in terms of the number of labeled stem cells that are required for high-field MRI studies. Overall this work has shown many of the benefits and the areas that need special attention of ultra high fields in MR. Three topics in MRI, MRS and MRSI were

  13. Ultra-high-field superconducting magnets

    Energy Technology Data Exchange (ETDEWEB)

    Hoard, R.W.; Cornish, D.N.; Scanlan, R.M.; Zbasnik, J.P.; Leber, R.L.; Hickman, R.B.; Lee, J.D.

    1983-08-01

    The following topics are considered: (1) superfluid helium for advanced magnets, (2) conductor reinforcement, (3) designing a 20-T, 2-m bore solenoidal coil, (4) coil size and conductor properties, (5) axial forces on the coil, (6) effect of radiation on the coil systems, and (7) helium-II transient heat transfer and coil protection. (MOW)

  14. High-Field Magnetization of Some Mn Alloys(Magnetism)

    OpenAIRE

    Tomiei, Hori; Hiroshi, Shiraishi; Hiroshi, Niida; Hiroaki, Kato; Giyuu, Kido; Yasuo, Yamaguchi; Yasuaki, Nakagawa; Shibaura Institute of Technology; Institute for Materials Research, Tohoku University

    1993-01-01

    We have made high-field magnetization measurements for some Mn alloys : ε-Mn_Ga with δ= -0.30, ε-(Mn_Fe_x)_3Sn with x=0.1 and 0.3, Fe_3Mn_4Ge_ and γ-(Mn_Fe_x)_Ga_y with x=0.44 and y=0.27. The ε-Mn_Ga has the hexagonal D0_ type structure and a distorted triangular antiferromagnetic spin structure. The hexagonal lattice is slightly distorted to an orthorhombic lattice at T_d of about 290 K with large magnetization. Pseudo-binary ε-(Mn_Fe_x)_3Sn has also the D0_ type structure, and the alloys wi...

  15. Radiofrequency solutions in clinical high field magnetic resonance

    NARCIS (Netherlands)

    Andreychenko, A.|info:eu-repo/dai/nl/341697672

    2013-01-01

    Magnetic resonance imaging (MRI) and spectroscopy (MRS) benefit from the sensitivity gain at high field (≥7T). However, high field brings also certain challenges associated with growing frequency and spectral dispersion. Frequency growth results in degraded performance of large volume radiofrequency

  16. Neutron diffraction study of anomalous high-field magnetic phases in TmNi2B2C

    DEFF Research Database (Denmark)

    Toft, K.N.; Abrahamsen, A.B.; Eskildsen, M.R.;

    2004-01-01

    .483,0,0), and Q(AII)=(0.496,0,0), all with the magnetic moment along the c axis. In zero and low fields the Tm 4f-moments order in a long wavelength transverse spin density wave with Q=Q(F). The magnetic Q(AI) structure is stabilized by an applied field of 1 T and a transition to Q(AII) is observed at 4 T......We present a (B,T)-phase diagram of the magnetic superconductor TmNi2B2C obtained by neutron scattering. The measurements were performed in magnetic fields up to 6 T applied along the crystalline a axis. The observed phases are characterized by three ordering vectors, Q(F)=(0.094,0.094,0),Q(AI)=(0.......90Yb0.10)Ni2B2C the Q(F)-->Q(AI) phase transition is also observed but at a larger transition field compared to the undoped compound. In (Tm0.85Yb0.15)Ni2B2C the Q(F) phase persists up to at least 1.8 T. The magnetic correlation length of the Q(AI) phase in TmNi2B2C measured parallel and perpendicular...

  17. Developments at the High Field Magnet Laboratory in Nijmegen

    Science.gov (United States)

    Perenboom, J. A. A. J.; Maan, J. C.; van Breukelen, M. R.; Wiegers, S. A. J.; den Ouden, A.; Wulffers, C. A.; van der Zande, W. J.; Jongma, R. T.; van der Meer, A. F. G.; Redlich, B.

    2013-03-01

    The High Field Magnet Laboratory at the Radboud University Nijmegen is rapidly expanding its capabilities. The developments encompass both organizational changes and new possibilities for research. The organization of the HFML was strengthened as a consequence of stronger participation of the Foundation for Fundamental Research on Matter (FOM), and an increase of the core-funding. This change makes that HFML is now considered on a national level as large research facility that operates at an international scale. At the same time work is underway to build new and powerful magnets, and provide electromagnetic radiation for magneto-spectroscopic studies. Electromagnetic radiation in the infrared and far-infrared spectrum will soon be available in the HFML with wavelengths between 3 μm and 1.5 mm, produced by the `FELIX' facility, comprising the long-wavelength free electron laser `FLARE' that in September 2011 produced its first light and the free electron lasers that have been moved from Rijnhuizen to Nijmegen. In magnet technology great strides are made to make magnets available for the user community with unprecedented performance: late in 2012 we hope to commission a new all-resistive magnet system that will generate a steady magnetic field as high as 38 T, by fully exploiting the maximum power of the installation, i.e. 20 MW, and using all available improvements in the design and construction of `Florida-Bitter' resistive magnets. We are also well underway with the design of a 45 T hybrid magnet system, using Nb3Sn superconductors and wind-and-react Cable-in-Conduit technology.

  18. On the origin of high-field magnetic white dwarfs

    CERN Document Server

    García-Berro, E; Lorén-Aguilar, P; Aznar-Siguán, G; Camacho, J; Külebi, B; Isern, J; Althaus, L G; Córsico, A H

    2012-01-01

    High-field magnetic white dwarfs have been long suspected to be the result of stellar mergers. However, the nature of the coalescing stars and the precise mechanism that produces the magnetic field are still unknown. Here we show that the hot, convective, differentially rotating corona present in the outer layers of the remnant of the merger of two degenerate cores is able to produce magnetic fields of the required strength that do not decay for long timescales. We also show, using an state-of-the-art Monte Carlo simulator, that the expected number of high-field magnetic white dwarfs produced in this way is consistent with that found in the solar neighborhood.

  19. First studies in the 45 T hybrid magnet at the NHMFL-Tallahassee: the high-field phases of organic and Kondo systems

    Science.gov (United States)

    Brooks, J. S.; Balicas, L.; Tokumoto, M.; Terashima, T.; Echizen, Y.; Takabatake, T.

    2001-01-01

    We have performed magnetoresistance measurements on an organic conductor, α-(BEDT-TTF) 2KHg(SCN) 4, and on a Kondo semiconductor, CeNiSn, at low temperatures and for fields up to 45 T in the hybrid magnet at the National High Magnetic Field Laboratory. We will discuss some new insight into a very controversial high-field phase of α-(BEDT-TTF) 2KHg(SCN) 4 gained from measurements of the anomalous temperature dependence of the quantum oscillations in the range 25-45 T. New information will also be presented on the temperature dependence of resistivity in the high-field state of CeNiSn, where questions of metallic versus semiconducting ground states arise. To acquaint researchers who anticipate using the facility in the near future, practical details concerning use of this new high-field resource are included.

  20. High-field magnetization of dilute rare earths in yttrium

    DEFF Research Database (Denmark)

    Touborg, P.; Høg, J.; Cock, G. J.;

    1974-01-01

    Magnetization measurements have been performed on single crystals of Y containing small amounts of Tb, Dy, or Er at 4.2 K in fields up to 295 × 105 A/m (370 kOe). Crystal-field and molecular-field parameters obtained from measurements of the initial susceptibility versus temperature give...... a satisfactory quantitative account of the high-field magnetization. This includes characteristic features due to the crossing and mixing of crystal-field levels....

  1. High-field Magnet Development toward the High Luminosity LHC

    Energy Technology Data Exchange (ETDEWEB)

    Apollinari, Giorgio [Fermilab

    2014-07-01

    The upcoming Luminosity upgrade of the LHC (HL-LHC) will rely on the use of Accelerator Quality Nb3Sn Magnets which have been the focus of an intense R&D effort in the last decade. This contribution will describe the R&D and results of Nb3Sn Accelerator Quality High Field Magnets development efforts, with emphasis on the activities considered for the HL-LHC upgrades.

  2. Survey of high field superconducting material for accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Scahlan, R.; Greene, A.F.; Suenaga, M.

    1986-05-01

    The high field superconductors which could be used in accelerator dipole magnets are surveyed, ranking these candidates with respect to ease of fabrication and cost as well as superconducting properties. Emphasis is on Nb/sub 3/Sn and NbTi. 27 refs., 2 figs. (LEW)

  3. A multireader reliability study comparing conventional high-field magnetic resonance imaging with extremity low-field MRI in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bird, Paul; Ejbjerg, Bo; Lassere, Marissa;

    2007-01-01

    The use of extremity low-field magnetic resonance imaging (E-MRI) is increasing, but relatively few data exist on its reproducibility and accuracy in comparison with high-field MRI, especially for multiple readers. The aim of this multireader exercise of rheumatoid arthritis wrist...

  4. A multireader reliability study comparing conventional high-field magnetic resonance imaging with extremity low-field MRI in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Bird, Paul; Ejbjerg, Bo; Lassere, Marissa;

    2007-01-01

    The use of extremity low-field magnetic resonance imaging (E-MRI) is increasing, but relatively few data exist on its reproducibility and accuracy in comparison with high-field MRI, especially for multiple readers. The aim of this multireader exercise of rheumatoid arthritis wrist and metacarpoph...

  5. Spontaneous radiation emission from short, high field strength magnetic devices

    Directory of Open Access Journals (Sweden)

    G. A. Krafft

    2006-01-01

    Full Text Available Since the earliest papers on undulators were published, it has been known how to calculate the spontaneous emission spectrum from short undulators when the magnetic field strength parameter is small compared to unity, or in “single” frequency sinusoidal undulators where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulator. Fewer general results have been obtained in the case where the magnetic device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the radiation spectrum for short, high-field magnetic devices. It is used to calculate the emission from some designs of recent interest.

  6. Homogenous BSCCO-2212 Round Wires for Very High Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Scott Campbell

    2012-06-30

    The performance demands on modern particle accelerators generate a relentless push towards higher field magnets. In turn, advanced high field magnet development places increased demands on superconducting materials. Nb3Sn conductors have been used to achieve 16 T in a prototype dipole magnet and are thought to have the capability for {approx}18 T for accelerator magnets (primarily dipoles but also higher order multipole magnets). However there have been suggestions and proposals for such magnets higher than 20 T. The High Energy Physics Community (HEP) has identified important new physics opportunities that are enabled by extremely high field magnets: 20 to 50 T solenoids for muon cooling in a muon collider (impact: understanding of neutrinos and dark matter); and 20+ T dipoles and quadrupoles for high energy hadron colliders (impact: discovery reach far beyond present). This proposal addresses the latest SBIR solicitation that calls for grant applications that seek to develop new or improved superconducting wire technologies for magnets that operate at a minimum of 12 Tesla (T) field, with increases up to 15 to 20 T sought in the near future (three to five years). The long-term development of accelerator magnets with fields greater than 20 T will require superconducting wires having significantly better high-field properties than those possessed by current Nb{sub 3}Sn or other A15 based wires. Given the existing materials science base for Bi-2212 wire processing, we believe that Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub y} (Bi-2212) round wires can be produced in km-long piece lengths with properties suitable to meet both the near term and long term needs of the HEP community. The key advance will be the translation of this materials science base into a robust, high-yield wire technology. While the processing and application of A15 materials have advanced to a much higher level than those of the copper oxide-based, high T{sub c} (HTS) counterparts, the HTS materials have

  7. Homogenous BSCCO-2212 Round Wires for Very High Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Scott Campbell

    2012-06-30

    The performance demands on modern particle accelerators generate a relentless push towards higher field magnets. In turn, advanced high field magnet development places increased demands on superconducting materials. Nb3Sn conductors have been used to achieve 16 T in a prototype dipole magnet and are thought to have the capability for {approx}18 T for accelerator magnets (primarily dipoles but also higher order multipole magnets). However there have been suggestions and proposals for such magnets higher than 20 T. The High Energy Physics Community (HEP) has identified important new physics opportunities that are enabled by extremely high field magnets: 20 to 50 T solenoids for muon cooling in a muon collider (impact: understanding of neutrinos and dark matter); and 20+ T dipoles and quadrupoles for high energy hadron colliders (impact: discovery reach far beyond present). This proposal addresses the latest SBIR solicitation that calls for grant applications that seek to develop new or improved superconducting wire technologies for magnets that operate at a minimum of 12 Tesla (T) field, with increases up to 15 to 20 T sought in the near future (three to five years). The long-term development of accelerator magnets with fields greater than 20 T will require superconducting wires having significantly better high-field properties than those possessed by current Nb{sub 3}Sn or other A15 based wires. Given the existing materials science base for Bi-2212 wire processing, we believe that Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub y} (Bi-2212) round wires can be produced in km-long piece lengths with properties suitable to meet both the near term and long term needs of the HEP community. The key advance will be the translation of this materials science base into a robust, high-yield wire technology. While the processing and application of A15 materials have advanced to a much higher level than those of the copper oxide-based, high T{sub c} (HTS) counterparts, the HTS materials have

  8. Micromagnetic simulation for high field sensors with perpendicular magnetizations

    Institute of Scientific and Technical Information of China (English)

    Jin Wei; Liu Yao-Wen

    2007-01-01

    In this paper, we present a micromagnetic design for high field sensors. The hard layer of the sensors is L10-FePt which is magnetized perpendicularly to film plane and the sense layer is NiFe which is magnetized in the film plane. The magnetization configurations of the hard and sense layers at different external magnetic fields have been simulated. In micromagnetic simulation, the sense field up to one tesla can be reached by using this sensor. We find that whether the sensor has a symmetric or an asymmetric field-sensing window is determined by the coercive field of the hard layer and the demagnetizing field of the sense layer.

  9. Applications of high dielectric materials in high field magnetic resonance

    Science.gov (United States)

    Haines, Kristina Noel

    At high magnetic fields, radiation losses, wavelength effects, self-resonance, and the high resistance of components all contribute to losses in conventional RF MRI coil designs. The hypothesis tested here is that these problems can be combated by the use of high permittivity ceramic materials at high fields. High permittivity ceramic dielectric resonators create strong uniform magnetic fields in compact structures at high frequencies and can potentially solve some of the challenges of high field coil design. In this study NMR probes were constructed for operation at 600 MHz (14.1 Tesla) and 900 MHz (21.1 Tesla) using inductively fed CaTiO3 (relative permittivity of 156-166) cylindrical hollow bore dielectric resonators. The designs showed the electric field is largely confined to the dielectric itself, with near zero values in the hollow bore, which accommodates the sample. The 600 MHz probe has an unmatched Q value greater than 2000. Experimental and simulation mapping of the RF field show good agreement, with the ceramic resonator giving a pulse width approximately 25% less than a loop gap resonator of similar inner dimensions. High resolution images, with voxel dimensions less than 50 microm3, have been acquired from fixed zebrafish samples, showing excellent delineation of several fine structures. The 900 MHz probe has an unmatched Q value of 940 and shows Q performance five times better than Alderman-Grant and loop-gap resonators of similar dimensions. High resolution images were acquired of an excised mouse spinal cord (25 microm 3) and an excised rat soleus muscle (20 microm3). The spatial distribution of electromagnetic fields within the human body can be tailored using external dielectric materials. Here, a new material is introduced with high dielectric constant and low background MRI signal. The material is based upon metal titanates, which can be made into geometrically formable suspensions in de-ionized water. The suspension's material properties are

  10. Towards Integrated Design and Modeling of High Field Accelerator Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Caspi, S.; Ferracin, P.

    2006-06-01

    The next generation of superconducting accelerator magnets will most likely use a brittle conductor (such as Nb{sub 3}Sn), generate fields around 18 T, handle forces that are 3-4 times higher than in the present LHC dipoles, and store energy that starts to make accelerator magnets look like fusion magnets. To meet the challenge and reduce the complexity, magnet design will have to be more innovative and better integrated. The recent design of several high field superconducting magnets have now benefited from the integration between CAD (e.g. ProE), magnetic analysis tools (e.g. TOSCA) and structural analysis tools (e.g. ANSYS). Not only it is now possible to address complex issues such as stress in magnet ends, but the analysis can be better detailed an extended into new areas previously too difficult to address. Integrated thermal, electrical and structural analysis can be followed from assembly and cool-down through excitation and quench propagation. In this paper we report on the integrated design approach, discuss analysis results and point out areas of future interest.

  11. Ultra-high field magnets for whole-body MRI

    Science.gov (United States)

    Warner, Rory

    2016-09-01

    For whole-body MRI, an ultra-high field (UHF) magnet is currently defined as a system operating at 7 T or above. Over 70 UHF magnets have been built, all with the same technical approach originally developed by Magnex Scientific Ltd. The preferred coil configuration is a compensated solenoid. In this case, the majority of the field is generated by a simple long solenoid that stretches the entire length of the magnet. Additional coils are wound on a separate former outside the main windings with the purpose of balancing the homogeneity. Most of the magnets currently in operation are passively shielded systems where the magnet is surrounded by a steel box of 200-870 tonnes of carbon steel. More recently actively shielded magnets have been built for operation at 7 T; in this case the stray field is controlled by with reverse turns wound on a separate former outside the primary coils. Protection against quench damage is much more complex with an actively shielded magnet design due to the requirement to prevent the stray field from increasing during a quench. In the case of the 7 T 900 magnet this controlled by combining some of the screening coils into each section of the protection circuit. Correction of the field variations caused by manufacturing tolerances and environmental effects are made with a combination of superconducting shims and passive shims. Modern UHF magnets operate in zero boil-off mode with the use of cryocoolers with cooling capacity at 4.2 K. Although there are no cryogen costs associated with normal operation UHF magnets require a significant volume (10 000-20 000 l) of liquid helium for the cool-down. Liquid helium is expensive therefore new methods of cool-down using high-power cryocoolers are being implemented to reduce the requirement.

  12. Design Studies and Optimization of High-Field Nb$_3$Sn Dipole Magnets for a Future Very High Energy PP Collider

    Energy Technology Data Exchange (ETDEWEB)

    Kashikhin, V. V. [Fermilab; Novitski, I. [Fermilab; Zlobin, A. V. [Fermilab

    2017-05-01

    High filed accelerator magnets with operating fields of 15-16 T based on the $Nb_3Sn$ superconductor are being considered for the LHC energy upgrade or a future Very High Energy pp Collider. Magnet design studies are being conducted in the U.S., Europe and Asia to explore the limits of the $Nb_3Sn$ accelerator magnet technology while optimizing the magnet design and performance parame-ters, and reducing magnet cost. The first results of these studies performed at Fermilab in the framework of the US-MDP are reported in this paper.

  13. THERMAL MODELS FOR THE FRESCA2 HIGH FIELD MAGNET

    CERN Document Server

    Pietrowicz, S

    2012-01-01

    This report presents the thermal studies and measurement that have been realized, at CEA Saclay, for the thermal design of the Fresca 2 magnet under development in EuCARD HFM program. The first part of the report is dedicated to the numerical study of the thermal behaviour of the Fresca 2 magnet in He II. The second part of the report concerns the experimental measurement on two composite insulation systems made of cyanate ester epoxy mix and tri-functional epoxy (TGPAP-DETDA) with S-glass fiber.

  14. High-Field Magnetization in PrCo2Si2 Single Crystals

    Science.gov (United States)

    Shigeoka, Toru; Fujii, Hironobu; Yonenobu, Kenji; Sugiyama, Kiyohiro; Date, Muneyuki

    1989-02-01

    Magnetic properties of PrCo2Si2 single crystals have been studied by measurements of high-field magnetization, magnetic susceptibility and electrical resistivity. Anomalous behaviors in the resistivity appear at three successive magnetic phase transition temperatures of 9, 17 and 30K. The magnetic susceptibility is highly anisotropic and is analyzed using the single-ion Hamiltonian, including the crystal-field and molecular-field effects. The thermal variations of the susceptibilities can be well reproduced by the crystal-field parameters estimated from the point-charge model. Metamagnetic transitions with four steps are observable in the c-axis magnetization process up to 300 kOe. The magnetization process is discussed in terms of the incommensurate exchange field model in the Ising system proposed by Date.

  15. Magnet Science and Technology for Basic Research at the High Field Laboratory for Superconducting Materials

    Institute of Scientific and Technical Information of China (English)

    渡辺和雄

    2007-01-01

    Since the first practical cryocooled superconducting magnet using a GM-cryocooler and high temperature superconducting current leads has been demonstrated successfully at the High Field Laboratory for Superconducting Materials (HFLSM), various kinds of cryocooled superconducting magnets in fields up to 15 T have been used to provide access for new research areas in fields of magneto-science. Recently, the HFLSM has succeeded in demonstrating a cryocooed 18 T high temperature superconducting magnet and a high field cryocooled 27.5 T hybrid magnet. Cryocooled magnet technology and basic research using high field magnets at the HFLSM are introduced.

  16. 2D/3D quench simulation using ANSYS for epoxy impregnated Nb3Sn high field magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ryuji Yamada et al.

    2002-09-19

    A quench program using ANSYS is developed for the high field collider magnet for three-dimensional analysis. Its computational procedure is explained. The quench program is applied to a one meter Nb{sub 3}Sn high field model magnet, which is epoxy impregnated. The quench simulation program is used to estimate the temperature and mechanical stress inside the coil as well as over the whole magnet. It is concluded that for the one meter magnet with the presented cross section and configuration, the thermal effects due to the quench is tolerable. But we need much more quench study and improvements in the design for longer magnets.

  17. High field magnet program at Brookhaven National Laboratory

    CERN Document Server

    Ghosh, A; Muratore, J; Parker, B; Sampson, W; Wanderer, P J; Willen, E

    2000-01-01

    The magnet program at Brookhaven National Laboratory (BNL) is focussed on superconducting magnets for particle accelerators. The effort includes magnet production at the laboratory and in industry, magnet R&D, and test facilities for magnets and superconductors. Nearly 2000 magnets-dipoles, quadrupoles, sextupoles and correctors for the arc and insertion regions-were produced for the Relativistic Heavy Ion Collider (RHIC), which is being commissioned. Currently, production of helical dipoles for the polarized proton program at RHIC, insertion region dipoles for the Large Hadron Collider (LHC) at CERN, and an insertion magnet system for the Hadron-Elektron-Ring- Analage (HERA) collider at Deutsches Elektronen-Synchrotron (DESY) is underway. The R&D effort is exploring dipoles with fields above 10 T for use in post-LHC colliders. Brittle superconductors-Nb/sub 3/Sn or HTS-are being used for these magnets. The superconductor test facility measures short-sample currents and other characteristics of sample...

  18. Conceptual Design of the 45 T Hybrid Magnet at the Nijmegen High Field Magnet Laboratory

    CERN Document Server

    Wiegers, SAJ; Bird, M D; Rook, J; Perenboom, J A A J; Wiegers, S A J; Bonito-Oliva, A; den Ouden, A

    2010-01-01

    A 45 T Hybrid Magnet System is being developed at the Nijmegen High Field Magnet Laboratory as part of the Nijmegen Center for Advanced Spectroscopy. The 45 T Hybrid Magnet System will be used in combination with far-infra-red light produced by a Free Electron Laser under construction directly adjacent to the High Field Magnet Laboratory. The superconducting outsert magnet will consist of three CICC coils wound on a single coil form, using Nb3Sn strands. A test program for strand and cable qualification is underway. The CICC will carry 13 kA and the coils will produce 12 T on axis field in a 600 mm warm bore. The nominal operating temperature will be 4.5 K maintained with forced-flow supercritical helium. The insert magnet will produce 33 T at 40 kA in a 32 mm bore consuming 20 MW, and will consist of four coils. The insert magnet will be galvanically and mechanically isolated from the outsert magnet. Complete system availability for users is expected in 2014. In this paper we will report on the conceptual de...

  19. Superconductor Requirements and Characterization for High Field Accelerator Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Barzi, E.; Zlobin, A. V.

    2015-05-01

    The 2014 Particle Physics Project Prioritization Panel (P5) strategic plan for U.S. High Energy Physics (HEP) endorses a continued world leadership role in superconducting magnet technology for future Energy Frontier Programs. This includes 10 to 15 T Nb3Sn accelerator magnets for LHC upgrades and a future 100 TeV scale pp collider, and as ultimate goal that of developing magnet technologies above 20 T based on both High Temperature Superconductors (HTS) and Low Temperature Superconductors (LTS) for accelerator magnets. To achieve these objectives, a sound conductor development and characterization program is needed and is herein described. This program is intended to be conducted in close collaboration with U.S. and International labs, Universities and Industry.

  20. High field accelerator magnet R&D in Europe

    CERN Document Server

    Devred, Arnaud; Bottura, L; Chorowski, M; Fabbricatore, P; Leroy, D; den Ouden, A; Rifflet, J M; Rossi, L; Vincent-Viry, O; Volpini, G

    2004-01-01

    The LHC magnet R&D program has shown that the limit of NbTi technology at 1.9 K was in the 10-to-10.5-T range. Hence, to go beyond the 10-T threshold, it is necessary to change the superconducting material. Given the state of the art in HTS, the only serious candidate is Nb3Sn. A series of dipole magnet models built at Twente University and LBNL as well as a vigorous program carried out at Fermilab have demonstrated the feasibility of Nb3Sn magnet technology. The next step is to bring this technology to maturity, which require further conductor and conductor insulation development and a simplification of manufacturing processes. After a brief history, we review ongoing R&D programs in Europe and we present the Next European Dipole (NED) initiative promoted by the European Steering Group on Accelerator R&D (ESGARD).

  1. High-Field Magnetization of Light Rare-Earth Metals

    DEFF Research Database (Denmark)

    McEwen, K.A.; Cock, G.J.; Roeland, L.W.;

    1973-01-01

    The magnetization of single crystals of Eu, Sm, Nd, Pr, and Pr-Nd alloys has been measured in fields up to 37 T (370 kG). The results give new information on the magnetic properties of these metals. Of particular interest is a first-order transition from a nonmagnetic to a metamagnetic phase...... in double-hexagonal close-packed Pr, due to the crossing of crystal-field levels, when a field of about 32 T is applied in the hard direction at low temperatures....

  2. Quasi permanent superconducting magnet of very high field

    Science.gov (United States)

    Ren, Y.; Liu, J.; Weinstein, R.; Chen, I. G.; Parks, D.; Xu, J.; Obot, V.; Foster, C.

    1993-01-01

    We report on persistent field in a quasi-permanent magnet made of high temperature superconductor. The material has an average of 40 percent molar excess of Y, relative to Y1Ba2Cu3O7 and has been irradiated with high energy light ions at 200 MeV. The magnet, which traps 1.52 T at 77.3 K, traps nearly 4 T at 64.5 K. No evidence of giant flux jump or sample cracking was observed.

  3. The new installation at the Nijmegen High Field Magnet Laboratory

    NARCIS (Netherlands)

    Perenboom, J.A.A.J.; Wiegers, S.A.J.; Christianen, P.C.M.; Zeitler, U.; Maan, J.C.

    2004-01-01

    For research in the highest continuous and pulsed magnetic fields large, complex and powerful installations are needed. A new 20 MW installation has been built at the University of Nijmegen. The ultra-low ripple power converter, delivering 40 kA at up to 500 V, provides the capability to perform exp

  4. Ultrasound versus high field magnetic resonance imaging in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Tan, York Kiat; Østergaard, Mikkel; Bird, Paul;

    2014-01-01

    Over the past decade there have been significant advances in the field of musculoskeletal imaging, especially in the application of ultrasound (US) and magnetic resonance imaging (MRI) to the management of rheumatoid arthritis (RA). Both modalities offer significant advantages over the previous...... standards of clinical examination and radiography, and allow direct visualisation of both joint inflammation and structural damage. Although measuring similar pathology, each of these imaging tools has its own benefits and limitations; understanding these will help researchers and clinicians to determine...

  5. High field accelerator magnet R&D in Europe

    NARCIS (Netherlands)

    Devred, A.; Baynham, D.E.; Bottura, L.; Chorowski, M.; Fabbricatore, P.; Leroy, D.; Ouden, den A.; Rifflet, J.M.; Rossi, L.; Vincent-Viry, O.; Volpini, G.

    2004-01-01

    The LHC magnet R&D Program has shown that the limit of NbTi technology at 1.8 K was in the range 10 to 10.5 T. Hence, to go beyond the 10-T threshold, it is necessary to change of superconducting material. Given the state of the art in HTS, the only serious candidate is Nb/sub 3/Sn. A series of dipo

  6. High Field Pulsed Magnets for Neutron Scattering at the Spallation Neutron Source

    Science.gov (United States)

    Granroth, G. E.; Lee, J.; Fogh, E.; Christensen, N. B.; Toft-Petersen, R.; Nojiri, H.

    2015-03-01

    A High Field Pulsed Magnet (HFPM) setup, is in use at the Spallation Nuetron Source(SNS), Oak Ridge National Laboratory. With this device, we recently measured the high field magnetic spin structure of LiNiPO4. The results of this study will be highlighted as an example of possible measurements that can be performed with this device. To further extend the HFPM capabilities at SNS, we have learned to design and wind these coils in house. This contribution will summarize the magnet coil design optimization procedure. Specifically by varying the geometry of the multi-layer coil, we arrive at a design that balances the maximum field strength, neutron scattering angle, and the field homogeneity for a specific set of parameters. We will show that a 6.3kJ capacitor bank, can provide a magnetic field as high as 30T for a maximum scattering angle around 40° with homogeneity of +/- 4 % in a 2mm diameter spherical volume. We will also compare the calculations to measurements from a recently wound test coil. This work was supported in part by the Lab Directors' Research and Development Fund of ORNL.

  7. High-field magnetization of Heusler compound Fe2Mn1 -xVxSi

    Science.gov (United States)

    Hiroi, Masahiko; Tazoko, Tomoya; Sano, Hiroaki; Shigeta, Iduru; Koyama, Keiichi; Kondo, Akihiro; Kindo, Koich; Manaka, Hirotaka; Terada, Norio

    2017-01-01

    Fe2MnSi exhibits a ferromagnetic transition at TC˜230 K and another transition to a phase with antiferromagnetic components at TA˜60 K. By substituting V for Mn, so as to obtain Fe2Mn1 -xVxSi , TA is revealed to decrease with x and then vanish around x ˜0.2 . In this study, the phase boundary of the transition at TA in the high-field range is found for 0 ≤x ≤0.15 with pulsed fields up to ˜70 T. The magnetization of Fe2Mn1 -xVxSi slowly increases even at the highest field of ˜70 T, though it occurs more gradually as x increases. We compare the magnetization for 0 ≤x ≤0.20 at 62 T with the Slater-Pauling rule, which holds when a Heusler compound is a half-metal, and find fairly good agreement. This suggests an intimate relation between the high-field phase and the half-metallic electronic structure, and that at the high-field limit the phase approaches the half-metallic state, which has been predicted by band-structure calculations.

  8. Quantification of local geometric distortion in structural magnetic resonance images: Application to ultra-high fields.

    Science.gov (United States)

    Lau, Jonathan C; Khan, Ali R; Zeng, Tony Y; MacDougall, Keith W; Parrent, Andrew G; Peters, Terry M

    2017-01-06

    Ultra-high field magnetic resonance imaging (MRI) provides superior visualization of brain structures compared to lower fields, but images may be prone to severe geometric inhomogeneity. We propose to quantify local geometric distortion at ultra-high fields in in vivo datasets of human subjects scanned at both ultra-high field and lower fields. By using the displacement field derived from nonlinear image registration between images of the same subject, focal areas of spatial uncertainty are quantified. Through group and subject-specific analysis, we were able to identify regions systematically affected by geometric distortion at air-tissue interfaces prone to magnetic susceptibility, where the gradient coil non-linearity occurs in the occipital and suboccipital regions, as well as with distance from image isocenter. The derived displacement maps, quantified in millimeters, can be used to prospectively evaluate subject-specific local spatial uncertainty that should be taken into account in neuroimaging studies, and also for clinical applications like stereotactic neurosurgery where accuracy is critical. Validation with manual fiducial displacement demonstrated excellent correlation and agreement. Our results point to the need for site-specific calibration of geometric inhomogeneity. Our methodology provides a framework to permit prospective evaluation of the effect of MRI sequences, distortion correction techniques, and scanner hardware/software upgrades on geometric distortion. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Theoretical Formula and Simulation of Cyclotron Magnet Shimming in High Field Environment

    Institute of Scientific and Technical Information of China (English)

    ZHANG; Dong-sheng; YANG; Jian-jun; LI; Ming

    2015-01-01

    In the computation of cyclotron magnet shimming,trim-rod and magnetic channel,one common process is to calculate the variation of magnet field caused by a small iron piece.Under the circumstance of superconducting cyclotron,high field approximate can be used and we can derive

  10. Magnetic, high-field EPR studies and catalytic activity of Schiff base tetranuclear CuII2FeIII2 complexes obtained by direct synthesis.

    Science.gov (United States)

    Nesterova, Oksana V; Chygorin, Eduard N; Kokozay, Vladimir N; Bon, Volodymyr V; Omelchenko, Irina V; Shishkin, Oleg V; Titiš, Ján; Boča, Roman; Pombeiro, Armando J L; Ozarowski, Andrew

    2013-12-28

    Two novel heterometallic complexes [Cu2Fe2(HL(1))2(H2L(1))2]·10DMSO (1) and [Cu2Fe2(HL(2))2(H2L(2))2]·2DMF (2) have been prepared using the open-air reaction of copper powder, iron(II) chloride and DMSO (1) or DMF (2) solutions of the polydentate Schiff base (H4L(1), 1; H4L(2), 2) formed in situ from salicylaldehyde (1) or 5-bromo-salicylaldehyde (2) and tris(hydroxymethyl)aminomethane. Crystallographic analysis revealed that both compounds are based on the centrosymmetric tetranuclear core {Cu(II)2Fe(III)2(μ-O)6} where metal centres are joined by μ-O bridges from the deprotonated ligands forming a nonlinear chain-like arrangement. Variable-temperature (1.8-300 K) magnetic susceptibility measurements of 1 and 2 showed a decrease of the effective magnetic moment value at low temperature, indicative of antiferromagnetic coupling (JCu-Fe/hc = -10.2 cm(-1), JFe-Fe/hc = -10.5 cm(-1) in 1, JCu-Fe/hc = -10.5 cm(-1), JFe-Fe/hc = -8.93 cm(-1) in 2) between the magnetic centres in both compounds. They reveal an exceptionally high catalytic activity in the oxidation of cyclohexane with hydrogen peroxide under mild conditions, with the best observed yield/TON combined values of 36%/596 and 44%/1.1 × 10(3) for 1 and 2, respectively.

  11. Gap Filling Ceramic Insulating Putty for High Field Magnets

    Science.gov (United States)

    Rice, J. A.; Rice, H. M.

    2008-03-01

    Gaps between the A15 superconducting cable and its supports can sometimes occur requiring expensive rework of the support or filling with a non-optimal material. Recently, a new ceramic putty has been developed that can fill these gaps to fully support the superconducting cable. This ceramic material can withstand the extreme temperature differences between the high temperature heat treatment and the cryogenic operation. Significant performance improvements have been made that will enable the insulating putty to be used in some accelerator magnet systems. Processing methods will be discussed as well as strength and thermal data.

  12. High-field magnetic phase transitions and spin excitations in magnetoelectric LiNiPO4

    DEFF Research Database (Denmark)

    Toft-Petersen, Rasmus; Jensen, Jens; Jensen, Thomas Bagger Stibius;

    2011-01-01

    The magnetically ordered phases and spin dynamics of magnetoelectric LiNiPO4 have been studied in fields up to 17.3 T along the c axis. Using neutron diffraction, we show that a previously proposed linearly polarized incommensurate (IC) structure exists only for temperatures just below the Neel......, the spiral structure is found to lock in to a period of five crystallographic unit cells along the b axis. Based on the neutron-diffraction data, combined with detailed magnetization measurements along all three crystallographic axes, we establish the magnetic phase diagrams for fields up to 17.3 T along c...... the linear and elliptical polarization of the IC structure, and that a generalization of the spin-wave theory, assuming the random-phase approximation, accounts for the inelastic scattering data obtained in the commensurable uniform phase at fields below 12 T as well as those obtained in the high-field IC...

  13. Pulsed high field magnets. An efficient way of shaping laser accelerated proton beams for application

    Energy Technology Data Exchange (ETDEWEB)

    Kroll, Florian; Schramm, Ulrich [Helmholtz-Zentrum Dresden - Rossendorf, 01328 Dresden (Germany); Technische Universitaet Dresden, 01062 Dresden (Germany); Bagnoud, Vincent; Blazevic, Abel; Busold, Simon [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Helmholtz Institut Jena, 07734 Jena (Germany); Brabetz, Christian; Schumacher, Dennis [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Deppert, Oliver; Jahn, Diana; Roth, Markus [Technische Universitaet Darmstadt, 64289 Darmstadt (Germany); Karsch, Leonhard; Masood, Umar [OncoRay-National Center for Radiation Research in Oncology, TU Dresden, 01307 Dresden (Germany); Kraft, Stephan [Helmholtz-Zentrum Dresden - Rossendorf, 01328 Dresden (Germany)

    2015-07-01

    Compact laser-driven proton accelerators are a potential alternative to complex, expensive conventional accelerators, enabling unique beam properties, like ultra-high pulse dose. Nevertheless, they still require substantial development in reliable beam generation and transport. We present experimental studies on capture, shape and transport of laser and conventionally accelerated protons via pulsed high-field magnets. These magnets, common research tools in the fields of solid state physics, have been adapted to meet the demands of laser acceleration experiments.Our work distinctively shows that pulsed magnet technology makes laser acceleration more suitable for application and can facilitate compact and efficient accelerators, e.g. for material research as well as medical and biological purposes.

  14. Correlating hemodynamic magnetic resonance imaging with high-field intracranial vessel wall imaging in stroke.

    Science.gov (United States)

    Langdon, Weston; Donahue, Manus J; van der Kolk, Anja G; Rane, Swati; Strother, Megan K

    2014-06-01

    Vessel wall magnetic resonance imaging at ultra-high field (7 Tesla) can be used to visualize vascular lesions noninvasively and holds potential for improving stroke-risk assessment in patients with ischemic cerebrovascular disease. We present the first multi-modal comparison of such high-field vessel wall imaging with more conventional (i) 3 Tesla hemodynamic magnetic resonance imaging and (ii) digital subtraction angiography in a 69-year-old male with a left temporal ischemic infarct.

  15. Superconductor and cable R&D for high field accelerator magnets at Fermilab

    CERN Document Server

    Barzi, E; Andreev, N; Bauer, P; Chichili, D R; Fratini, M; Elementi, L; Hoffman, J; Limon, P J; Mattafirri, S; Rey, J M; Yamada, R; Zlobin, A V

    2002-01-01

    This paper presents past results and future goals of the Nb/sub 3/Sn strand and cable R&D being performed within the High Field Magnet program at Fermilab. Research tools include a reaction site for Nb /sub 3/Sn, a Short Sample Test Facility, a Scanning Electron Microscope, and a 28-strand cabling machine. Strands of various designs and diameters produced with the Internal Tin, Modified Jelly Roll, and Powder-in-Tube methods, and several Rutherford-type cables were studied. (18 refs).

  16. High-Field Magnetization of the Pyrochlore Compound Gd2Ti2O7

    Science.gov (United States)

    Narumi, Yasuo; Kikkawa, Akiko; Katsumata, Koichi; Honda, Zentaro; Hagiwara, Masayuki; Kindo, Koichi

    2006-09-01

    High-field magnetization measurements have been preformed on a single crystal sample of the pyrochlore compound Gd2Ti2O7 using a pulse magnet in conjunction with a dilution refrigerator. The magnetization curve at 0.3 K reveals two magnetic phase transitions when the magnetic field is applied along b [111]. At temperatures slightly above TN, a magnetization plateau appears around 5 T and the magnetization increases again from about 15 T with a convex curvature. It is considered that this crossover is due to a competition among thermal fluctuations, short-range antiferromagnetic ordering and geometrical frustration.

  17. Considerations on a Cost Model for High-Field Dipole Arc Magnets for FCC

    CERN Document Server

    AUTHOR|(CDS)2078700; Durante, Maria; Lorin, Clement; Martinez, Teresa; Ruuskanen, Janne; Salmi, Tiina; Sorbi, Massimo; Tommasini, Davide; Toral, Fernando

    2017-01-01

    In the frame of the European Circular Collider (EuroCirCol), a conceptual design study for a post-Large Hadron Collider (LHC) research infrastructure based on an energy-frontier 100 TeV circular hadron collider [1]–[3], a cost model for the high-field dipole arc magnets is being developed. The aim of the cost model in the initial design phase is to provide the basis for sound strategic decisions towards cost effective designs, in particular: (A) the technological choice of superconducting material and its cost, (B) the target performance of Nb3Sn superconductor, (C) the choice of operating temperature (D) the relevant design margins and their importance for cost, (E) the nature and extent of grading, and (F) the aperture’s influence on cost. Within the EuroCirCol study three design options for the high field dipole arc magnets are under study: cos − θ [4], block [5], and common-coil [6]. Here, in the advanced design phase, a cost model helps to (1) identify the cost drivers and feed-back this informati...

  18. Powder-in-Tube (PIT) Nb3Sn conductors for high-field magnets

    NARCIS (Netherlands)

    Lindenhovius, J.H.; Hornsveld, E.M.; den Ouden, A.; Wessel, Wilhelm A.J.; ten Kate, Herman H.J.

    2000-01-01

    New Nb3Sn conductors, based on the powder-in-tube (PIT) process, have been developed for application in accelerator magnets and high-field solenoids. For application in accelerator magnets, SMI has developed a binary 504 filament PIT conductor by optimizing the manufacturing process and adjustment o

  19. Powder-in-Tube (PIT) Nb3Sn conductors for high-field magnets

    NARCIS (Netherlands)

    Lindenhovius, J.H.; Hornsveld, E.M.; den Ouden, A.; Wessel, Wilhelm A.J.; ten Kate, Herman H.J.

    2000-01-01

    New Nb3Sn conductors, based on the powder-in-tube (PIT) process, have been developed for application in accelerator magnets and high-field solenoids. For application in accelerator magnets, SMI has developed a binary 504 filament PIT conductor by optimizing the manufacturing process and adjustment

  20. High-field proton magnetic resonance spectroscopy reveals metabolic effects of normal brain aging.

    Science.gov (United States)

    Harris, Janna L; Yeh, Hung-Wen; Swerdlow, Russell H; Choi, In-Young; Lee, Phil; Brooks, William M

    2014-07-01

    Altered brain metabolism is likely to be an important contributor to normal cognitive decline and brain pathology in elderly individuals. To characterize the metabolic changes associated with normal brain aging, we used high-field proton magnetic resonance spectroscopy in vivo to quantify 20 neurochemicals in the hippocampus and sensorimotor cortex of young adult and aged rats. We found significant differences in the neurochemical profile of the aged brain when compared with younger adults, including lower aspartate, ascorbate, glutamate, and macromolecules, and higher glucose, myo-inositol, N-acetylaspartylglutamate, total choline, and glutamine. These neurochemical biomarkers point to specific cellular mechanisms that are altered in brain aging, such as bioenergetics, oxidative stress, inflammation, cell membrane turnover, and endogenous neuroprotection. Proton magnetic resonance spectroscopy may be a valuable translational approach for studying mechanisms of brain aging and pathology, and for investigating treatments to preserve or enhance cognitive function in aging.

  1. High-field magnetization of NpRhGa{sub 5}

    Energy Technology Data Exchange (ETDEWEB)

    Sugiyama, K. [Graduate School of Sciences, Osaka University, Toyonaka, Osaka 560-0043 (Japan)]. E-mail: sugiyama@phys.sci.osaka-u.ac.jp; Honda, D. [Graduate School of Sciences, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Nakashima, H. [Graduate School of Sciences, Osaka University, Toyonaka, Osaka 560-0043 (Japan); Aoki, D. [IMR, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Yamamoto, E. [Advanced Science Research Center, JAERI, Tokai, Ibaraki 319-1195 (Japan); Nakamura, A. [Advanced Science Research Center, JAERI, Tokai, Ibaraki 319-1195 (Japan); Honma, K. [IMR, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Shiokawa, Y. [IMR, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Kindo, K. [ISSP, The University of Tokyo, Kashiwanoha 5-1-5, Kashiwa, Chiba 277-8581 (Japan); Hagiwara, M. [KYOKUGEN, Osaka University, Toyonaka, Osaka 560-8531 (Japan); Onuki, Y. [Graduate School of Sciences, Osaka University, Toyonaka, Osaka 560-0043 (Japan)

    2006-05-01

    We have measured the high-field magnetization of NpRhGa{sub 5} with the tetragonal structure and found the sharp metamagnetic transition with a sharp step at 26T in the field along the [100] direction at 4.2K. The magnetization saturates above 38T, with 0.43{mu}{sub B}/Np. The H-T phase diagram was determined by the magnetization curves at various temperatures.

  2. Nb3Sn High Field Magnets for the High Luminosity LHC Upgrade Project

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosio, Giorgio

    2015-06-01

    The High Luminosity upgrade of the Large Hadron Collider at CERN requires a new generation of high field superconducting magnets. High field large aperture quadrupoles (MQXF) are needed for the low-beta triplets close to the ATLAS and CMS detectors, and high field two-in-one dipoles (11 T dipoles) are needed to make room for additional collimation. The MQXF quadrupoles, with a field gradient of 140 T/m in 150 mm aperture, have a peak coil field of 12.1 T at nominal current. The 11 T dipoles, with an aperture of 60 mm, have a peak coil field of 11.6 T at nominal current. Both magnets require Nb3Sn conductor and are the first applications of this superconductor to actual accelerator magnets.

  3. Design of the EuCARD High-Field Model Dipole Magnet FRESCA2

    CERN Document Server

    Milanese, A; Durante, M; Manil, P; Perez, J C; Rifflet, J M; de Rijk, G; Rondeaux, F

    2012-01-01

    This paper reports on the design of FRESCA2, a dipole magnet model wound with Nb3Sn Rutherford cable. This magnet is one of the deliverables of the High Field Magnets work package of the European FP7-EuCARD project. The nominal magnetic flux density of 13 Tesla in a 100 mm bore will make it suitable for upgrading the FRESCA cable test facility at CERN. The magnetic layout is based on a block coil, with four layers per pole. The mechanical structure is designed to provide adequate pre-stress, through the use of bladders, keys and an aluminum alloy shrinking cylinder.

  4. Tuning magnetic disorder in diluted magnetic semiconductors using high fields to 89 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Crooker, Scott A [Los Alamos National Laboratory; Samarth, Nitin [PENN STATE U

    2008-01-01

    We describe recent and ongoing studies at the National High Magnetic Field Laboratory at Los Alamos using the new '100 Tesla Multi-Shot Magnet', which is presently delivering fields up to {approx}89 T during its commissioning. We discuss the first experiments performed in this magnet system, wherein the linewidth of low-temperature photoluminescence spectra was used to directly reveal the degree of magnetic alloy disorder 'seen' by excitons in single Zn{sub 0.80}Cd{sub 0.22}Mn{sub 0.08}Se quantum wells. The magnetic potential landscape in II-VI diluted magnetic semiconductors (DMS) is typically smoothed when the embedded Mn{sup 2+} spins align in an applied field. However, an important (but heretofore untested) prediction of current models of compositional disorder is that magnetic alloy fluctuations in many DMS compounds should increase again in very large magnetic fields approaching 100 T. We observed precisely this increase above {approx}70 T, in agreement with a simple model of magnetic alloy disorder.

  5. Double degenerate mergers as progenitors of high-field magnetic white dwarfs

    CERN Document Server

    García--Berro, E; Aznar--Siguán, G; Torres, S; Camacho, J; Althaus, L G; Córsico, A H; Külebi, B; Isern, J

    2012-01-01

    High-field magnetic white dwarfs have been long suspected to be the result of stellar mergers. However, the nature of the coalescing stars and the precise mechanism that produces the magnetic field are still unknown. Here we show that the hot, convective, differentially rotating corona present in the outer layers of the remnant of the merger of two degenerate cores is able to produce magnetic fields of the required strength that do not decay for long timescales. We also show, using an state-of-the-art Monte Carlo simulator, that the expected number of high-field magnetic white dwarfs produced in this way is consistent with that found in the Solar neighborhood.

  6. High field septum magnet using a superconducting shield for the Future Circular Collider

    CERN Document Server

    AUTHOR|(CDS)2069375

    2017-01-01

    A zero-field cooled superconducting shield is proposed to realize a high-field (3–4 T) septum magnet for the Future Circular Collider hadron-hadron (FCC-hh) ring. Three planned prototypes using different materials and technical solutions are presented, which will be used to evaluate the feasibility of this idea as a part of the FCC study. The numerical simulation methods are described to calculate the field patterns around such a shield. A specific excitation current configuration is presented that maintains a fairly homogeneous field outside of a rectangular shield in a wide range of field levels from 0 to 3 Tesla. It is shown that a massless septum configuration (with an opening in the shield) is also possible and gives satisfactory field quality with realistic superconducting material properties.

  7. High field nuclear magnetic resonance in transition metal substituted BaFe2As2

    Science.gov (United States)

    Garitezi, T. M.; Lesseux, G. G.; Rosa, P. F. S.; Adriano, C.; Reyes, A. P.; Kuhns, P. L.; Pagliuso, P. G.; Urbano, R. R.

    2014-05-01

    We report high field 75As nuclear magnetic resonance (NMR) measurements on Co and Cu substituted BaFe2As2 single crystals displaying same structural/magnetic transition T0≃128 K. From our anisotropy studies in the paramagnetic state, we strikingly found virtually identical quadrupolar splitting and consequently the quadrupole frequency νQ≃2.57(1) MHz for both compounds, despite the claim that each Cu delivers 2 extra 3d electrons in BaFe2As2 compared to Co substitution. These results allow us to conclude that a subtle change in the crystallographic structure, particularly in the Fe-As tetrahedra, must be the most probable tuning parameter to determine T0 in this class of superconductors rather than electronic doping. Furthermore, our NMR data around T0 suggest coexistence of tetragonal/paramagnetic and orthorhombic/antiferromagnetic phases between the structural and the spin density wave magnetic phase transitions, similarly to what was reported for K-doped BaFe2As2 [Urbano et al., Phys. Rev. Lett. 105, 107001 (2010)].

  8. High-field electron transport in GaN under crossed electric and magnetic fields

    Science.gov (United States)

    Kochelap, V. A.; Korotyeyev, V. V.; Syngayivska, G. I.; Varani, L.

    2015-10-01

    High-field electron transport studied in crossed electric and magnetic fields in bulk GaN with doping of 1016 cm-3, compensation around 90% at the low lattice temperature (30 K). It was found the range of the magnetic and electric fields where the non-equilibrium electron distribution function has a complicated topological structure in the momentum space with a tendency to the formation of the inversion population. Field dependences of dissipative and Hall components of the drift velocity were calculated for the samples with short- and open- circuited Hall contacts in wide ranges of applied electric (0 — 20 kV/cm) and magnetic (1 — 10 T) fields. For former sample, field dependences of dissipative and Hall components of the drift velocity have a non-monotonic behavior. The dissipative component has the inflection point which corresponds to the maximum point of the Hall component. For latter sample, the drift velocity demonstrate a usual sub-linear growth without any critical points. We found that GaN samples with controlled resistance of the Hall circuit can be utilized as a electronic high-power switch.

  9. Advances in high-field magnetic resonance spectroscopy in Alzheimer's disease.

    Science.gov (United States)

    Zhang, Ningnannan; Song, Xiaowei; Bartha, Robert; Beyea, Steven; D'Arcy, Ryan; Zhang, Yunting; Rockwood, Kenneth

    2014-05-01

    Alzheimer's disease (AD) affects several important molecules in brain metabolism. The resulting neurochemical changes can be quantified non-invasively in localized brain regions using in vivo single-voxel proton magnetic resonance spectroscopy (SV 1H MRS). Although the often heralded diagnostic potential of MRS in AD largely remains unfulfilled, more recent use of high magnetic fields has led to significantly improved signal-to-noise ratios and spectral resolutions, thereby allowing clinical applications with increased measurement reliability. The present article provides a comprehensive review of SV 1H MRS studies on AD at high magnetic fields (3.0 Tesla and above). This review suggests that patterned regional differences and longitudinal alterations in several neurometabolites are associated with clinically established AD. Changes in multiple metabolites are identifiable even at early stages of AD development. By combining information of neurochemicals in different brain regions revealing either pathological or compensatory changes, high field MRS can be evaluated in AD diagnosis and in the detection of treatment effects. To achieve this, standardization of data acquisition and analytical approaches is needed.

  10. Nb$_3$Sn High Field Magnets for the High Luminosity LHC Upgrade Project

    CERN Document Server

    AUTHOR|(CDS)2075881

    2015-01-01

    The high luminosity upgrade of the Large Hadron Collider at CERN requires a new generation of high field superconducting magnets. High field large aperture quadrupoles (MQXF) are needed for the low-beta triplets close to the ATLAS and CMS detectors, and high field two-in-one dipoles (11-T dipoles) are needed to make room for additional collimation. The MQXF quadrupoles, with a field gradient of 140 T/m in 150 mm aperture, have a peak coil field of 12.1 T at nominal current. The 11-T dipoles, with an aperture of 60 mm, have a peak coil field of 11.6 T at nominal current. Both magnets require Nb3Sn conductor and are the first applications of this superconductor to actual accelerator magnets. Collaboration between the US LARP (LHC Accelerator Research Program) and CERN is developing the MQXF magnets, whereas the 11-T dipole magnets are being developed by CERN and Fermilab. This paper reviews the status of Nb3Sn technology for accelerator magnets, discusses its main challenges, and discusses how the MQXF and 11-T...

  11. Studies on the reliability of high-field intra-operative MRI in brain glioma resection

    Directory of Open Access Journals (Sweden)

    Zhi-jun SONG

    2011-07-01

    Full Text Available Objective To evaluate the reliability of high-field intra-operative magnetic resonance imaging(iMRI in detecting the residual tumors during glioma resection.Method One hundred and thirty-one cases of brain glioma(69 males and 62 females,aged from 7 to 79 years with mean of 39.6 years hospitalized from Nov.2009 to Aug.2010 were involved in present study.All the patients were evaluated using magnetic resonance imaging(MRI before the operation.The tumors were resected under conventional navigation microscope,and the high-field iMRI was used for all the patients when the operators considered the tumor was satisfactorily resected,while the residual tumor was difficult to detect under the microscope,but resected after being revealed by high-field iMRI.Histopathological examination was performed.The patients without residual tumors recieved high-field MRI scan at day 4 or 5 after operation to evaluate the accuracy of high-field iMRI during operation.Results High quality intra-operative images were obtained by using high-field iMRI.Twenty-eight cases were excluded because their residual tumors were not resected due to their location too close to functional area.Combined with the results of intra-operative histopathological examination and post-operative MRI at the early recovery stage,the sensitivity of high-field iMRI in residual tumor diagnosis was 98.0%(49/50,the specificity was 94.3%(50/53,and the accuracy was 96.1%(99/103.Conclusion High-quality intra-operative imaging could be acquired by high-field iMRI,which maybe used as a safe and reliable method in detecting the residual tumors during glioma resection.

  12. Development of High-Field Permanent Magnetic Circuits for NMRI/MRI and Imaging on Mice

    Directory of Open Access Journals (Sweden)

    Guangxin Wang

    2016-01-01

    Full Text Available The high-field permanent magnetic circuits of 1.2 T and 1.5 T with novel magnetic focusing and curved-surface correction are developed. The permanent magnetic circuit comprises a magnetic yoke, main magnetic steel, nonspherical curved-surface magnetic poles, plugging magnetic steel, and side magnetic steel. In this work, a novel shimming method is proposed for the effective correction of base magnetic field (B0 inhomogeneities, which is based on passive shimming on the telescope aspheric cutting, grinding, and fine processing technology of the nonspherical curved-surface magnetic poles and active shimming adding higher-order gradient coils. Meanwhile, the magnetic resonance imaging dedicated alloy with high-saturation magnetic field induction intensity and high electrical resistivity is developed, and nonspherical curved-surface magnetic poles which are made of the dedicated alloy have very good anti-eddy-current effect. In addition, the large temperature coefficient problem of permanent magnet can be effectively controlled by using a high quality temperature controller and deuterium external locking technique. Combining our patents such as gradient coil, RF coil, and integration computer software, two kinds of small animal Micro-MRI instruments are developed, by which the high quality MRI images of mice were obtained.

  13. High-field magnetization process of granular Co-Cu alloys prepared by melt spinning

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    High solid-solubility Co15Cu35 alloys have been prepared by melt spinning and submitted to isothermal and anisothermal annealing to obtain granular alloys.The X-ray diffraction(XRD) patterns were measured to invesugate the decomposition of supersaturated solid solution induced by annealing.The atomic diffusion and structural evolution during the heat treatment were investigated.In view of the problems limiting their appllcation.the high-field magneazation curves were measured.By a fit to the high-field magnetization curves,the granuiar alloys are found hard to be magnetically saturated at the early stage of nucleation and growth.The magnetization behavior was correlaced to the annealed-induced structureal evolution and also to the magnetoresistance effect.

  14. Very high field magnetization and AC susceptibility of native horse spleen ferritin

    Energy Technology Data Exchange (ETDEWEB)

    Guertin, R.P. [Department of Physics and Astronomy, Room 201, Science and Technology Center, Tufts University, Medford, MA 02155 (United States)]. E-mail: robert.guertin@tufts.edu; Harrison, N. [National High Magnetic Field Laboratory, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Zhou, Z.X. [MS6056, Oak Ridge National Laboratory, Oak Ridge, TN 37830 (United States); McCall, S. [Lawrence Livermore National Laboratory, PO Box 808, Livermore, CA 94551 (United States); Drymiotis, F. [Department of Physics and Astronomy, Clemson University, Clemson, SC 29634 (United States)

    2007-01-15

    The magnetization of native horse spleen ferritin protein is measured in pulsed magnetic fields to 55 T at T=1.52 K. The magnetization rises smoothly with negative curvature due to uncompensated Fe{sup 3+} spins and with a large high field slope due to the underlying antiferromagnetic ferritin core. Even at highest fields the magnetic moment is only {approx}4% of the saturation moment of the full complement of Fe{sup 3+} in the ferritin molecule. The AC magnetic susceptibility, {chi} {sub AC}(T,f), responding to the uncompensated spins, reaches a maximum near the superparamagnetic blocking temperature with the temperature of the maximum, T {sub M}, varying with excitation frequency, T {sub M} {sup -1} {alpha} log f for 10{<=}f{<=}10{sup 4} Hz.

  15. A magnetic trap for high-field seeking neutron spin states

    Directory of Open Access Journals (Sweden)

    Th. Brenner

    2015-02-01

    Full Text Available A first experimental demonstration of a new type of magnetic trap for ultra-cold neutrons is presented. High-field seeking spin-states are trapped in a potential formed by the magnetic field of a straight wire and a repulsive coating on the wire surface. Life-times of the trapped neutrons of 60 s could be observed. This configuration can in principle be used to form bound states of the wave function on the surface of the wire to probe new forces at short distances. Further applications include the use as a guide and selector for perfectly polarized neutrons.

  16. A magnetic trap for high-field seeking neutron spin states

    Energy Technology Data Exchange (ETDEWEB)

    Brenner, Th. [Institut Laue-Langevin, 38042 Grenoble Cedex 9 (France); Chesnevskaya, S. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Fierlinger, P., E-mail: peter.fierlinger@tum.de [Physik Department, Technische Universität München, D-85748 Garching (Germany); Geltenbort, P. [Institut Laue-Langevin, 38042 Grenoble Cedex 9 (France); Gutsmiedl, E. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Lauer, T. [Forschungsneutronenquelle Heinz Maier-Leibnitz, Technische Universität München, D-85748 Garching (Germany); Rezai, K. [University of California at Berkeley, CA 94720 (United States); Rothe, J. [Physik Department, Technische Universität München, D-85748 Garching (Germany); Zechlau, T. [Forschungsneutronenquelle Heinz Maier-Leibnitz, Technische Universität München, D-85748 Garching (Germany); Zou, R. [University of California at Berkeley, CA 94720 (United States)

    2015-02-04

    A first experimental demonstration of a new type of magnetic trap for ultra-cold neutrons is presented. High-field seeking spin-states are trapped in a potential formed by the magnetic field of a straight wire and a repulsive coating on the wire surface. Life-times of the trapped neutrons of 60 s could be observed. This configuration can in principle be used to form bound states of the wave function on the surface of the wire to probe new forces at short distances. Further applications include the use as a guide and selector for perfectly polarized neutrons.

  17. High-field magnetization of rare-earth ions in scandium

    DEFF Research Database (Denmark)

    Roeland, L. W.; Touborg, P.

    1978-01-01

    The magnetic moments of Tb, Dy, or Er ions in dilute Sc single-crystal alloys have been measured in fields up to 280 × 105 A/m (350 kOe). The Zeeman energies in this high field are comparable to the total crystal-field splittings. This gives rise to characteristic features in the magnetization...... curves. The crystal-field parameters obtained previously from experiments in low fields and the Zeeman interaction give a satisfactory quantitative acount of the experimental results....

  18. The formation of high-field magnetic white dwarfs from common envelopes

    CERN Document Server

    Nordhaus, J; Spiegel, D S; Metzger, B D; Blackman, E G

    2010-01-01

    The origin of highly-magnetized white dwarfs has remained a mystery since their initial discovery. Recent observations indicate that the formation of high-field magnetic white dwarfs is intimately related to strong binary interactions during post-main-sequence phases of stellar evolution. If a low-mass companion, such as a planet, brown dwarf, or low-mass star is engulfed by a post-main-sequence giant, the hydrodynamic drag in the envelope of the giant leads to a reduction of the companion's orbit. Sufficiently low-mass companions in-spiral until they are shredded by the strong gravitational tides near the white dwarf core. Subsequent formation of a super-Eddington accretion disk from the disrupted companion inside a common envelope can dramatically amplify magnetic fields via a dynamo. Here, we show that these disk-generated fields are sufficiently strong to explain the observed range of magnetic field strengths for isolated, high-field magnetic white dwarfs. A higher-mass binary analogue may also contribute...

  19. Formation of high-field magnetic white dwarfs from common envelopes.

    Science.gov (United States)

    Nordhaus, Jason; Wellons, Sarah; Spiegel, David S; Metzger, Brian D; Blackman, Eric G

    2011-02-22

    The origin of highly magnetized white dwarfs has remained a mystery since their initial discovery. Recent observations indicate that the formation of high-field magnetic white dwarfs is intimately related to strong binary interactions during post-main-sequence phases of stellar evolution. If a low-mass companion, such as a planet, brown dwarf, or low-mass star, is engulfed by a post-main-sequence giant, gravitational torques in the envelope of the giant lead to a reduction of the companion's orbit. Sufficiently low-mass companions in-spiral until they are shredded by the strong gravitational tides near the white dwarf core. Subsequent formation of a super-Eddington accretion disk from the disrupted companion inside a common envelope can dramatically amplify magnetic fields via a dynamo. Here, we show that these disk-generated fields are sufficiently strong to explain the observed range of magnetic field strengths for isolated, high-field magnetic white dwarfs. A higher-mass binary analogue may also contribute to the origin of magnetar fields.

  20. Vol. 34 - Optimization of quench protection heater performance in high-field accelerator magnets through computational and experimental analysis

    CERN Document Server

    Salmi, Tiina

    2016-01-01

    Superconducting accelerator magnets with increasingly hi gh magnetic fields are being designed to improve the performance of the Large Hadron Collider (LHC) at CERN. One of the technical challenges is the magnet quench p rotection, i.e., preventing damage in the case of an unexpected loss of superc onductivity and the heat generation related to that. Traditionally this is d one by disconnecting the magnet current supply and using so-called protection he aters. The heaters suppress the superconducting state across a large fraction of the winding thus leading to a uniform dissipation of the stored energy. Preli minary studies suggested that the high-field Nb 3 Sn magnets under development for the LHC luminosity upgrade (HiLumi) could not be reliably protected using the existing heaters. In this thesis work I analyzed in detail the present state-of-the-art protection heater technology, aiming to optimize its perfo rmance and evaluate the prospects in high-field magnet protection. The heater efficiency analyses ...

  1. Exchange and crystal field in Sm-based magnets. I. Inelastic neutron scattering and high-field magnetization study of Sm2Fe17 and Sm2Fe17N3

    Science.gov (United States)

    Sippel, A.; Jahn, L.; Loewenhaupt, M.; Eckert, D.; Kerschl, P.; Handstein, A.; Müller, K.-H.; Wolf, M.; Kuz'Min, M. D.; Steinbeck, L.; Richter, M.; Teresiak, A.; Bewley, R.

    2002-02-01

    A peak is detected in the high-energy inelastic neutron scattering spectra of Sm2Fe17 and Sm2Fe17N3, which is associated with the intermultiplet transition in the 4f shell of samarium. The peak in the nitride Sm2Fe17N3 is situated at a lower energy (163 meV) as compared with the parent compound Sm2Fe17 (177 meV). The peak position provides direct information on the strength of the exchange field on Sm in both compounds: Bex=380 and 270 T in Sm2Fe17 and Sm2Fe17N3, respectively. The 30% reduction in Bex as a result of nitrogenating Sm2Fe17 is consistent with the earlier discovered similar effect in Gd2Fe17. High-field (B=-28 meV.

  2. Stress management as an enabling technology for high-field superconducting dipole magnets

    Science.gov (United States)

    Holik, Eddie Frank, III

    This dissertation examines stress management and other construction techniques as means to meet future accelerator requirement demands by planning, fabricating, and analyzing a high-field, Nb3Sn dipole. In order to enable future fundamental research and discovery in high energy accelerator physics, bending magnets must access the highest fields possible. Stress management is a novel, propitious path to attain higher fields and preserve the maximum current capacity of advanced superconductors by managing the Lorentz stress so that strain induced current degradation is mitigated. Stress management is accomplished through several innovative design features. A block-coil geometry enables an Inconel pier and beam matrix to be incorporated in the windings for Lorentz Stress support and reduced AC loss. A laminar spring between windings and mica paper surrounding each winding inhibit any stress transferral through the support structure and has been simulated with ALGORRTM. Wood's metal filled, stainless steel bladders apply isostatic, surface-conforming preload to the pier and beam support structure. Sufficient preload along with mica paper sheer release reduces magnet training by inhibiting stick-slip motion. The effectiveness of stress management is tested with high-precision capacitive stress transducers and strain gauges. In addition to stress management, there are several technologies developed to assist in the successful construction of a high-field dipole. Quench protection has been designed and simulated along with full 3D magnetic simulation with OPERARTM. Rutherford cable was constructed, and cable thermal expansion data was analysed after heat treatment. Pre-impregnation analysis techniques were developed due to elemental tin leakage in varying quantities during heat treatment from each coil. Robust splicing techniques were developed with measured resistivites consistent with nO joints. Stress management has not been incorporated by any other high field dipole

  3. Powder-in-tube (PIT) $Nb_{3}Sn$ conductors for high-field magnets

    CERN Document Server

    Lindenhovius, J L H; den Ouden, A; Wessel, W A J; ten Kate, H H J

    2000-01-01

    New Nb/sub 3/Sn conductors, based on the powder-in-tube (PIT) process, have been developed for application in accelerator magnets and high-field solenoids. For application in accelerator magnets, SMI has developed a binary 504 filament PIT conductor by optimizing the manufacturing process and adjustment of the conductor lay-out. It uniquely combines a non-copper current density of 2680 A/mm/sup 2/@10 T with an effective filament diameter of about 20 mu m. This binary conductor may be used in a 10 T, wide bore model separator dipole magnet for the LHC, which is being developed by a collaboration of the University of Twente and CERN. A ternary (Nb/7.5wt%Ta)/sub 3/Sn conductor containing 37 filaments is particularly suited for application in extremely high-field superconducting solenoids. This wire features a copper content of 43%, a non-copper current density of 217 A/mm/sup 2/@20 T and a B/sub c2/ of 25.6 T. The main issues and the experimental results of the development program of PIT Nb/sub 3/Sn conductors a...

  4. Thermal Design of an Nb3Sn High Field Accelerator Magnet

    CERN Document Server

    Pietrowicz, S

    2011-01-01

    Within the framework of the European project EuCARD, a Nb3Sn high field accelerator magnet is under design to serve as a test bed for future high field magnets and to upgrade the vertical CERN cable test facility, Fresca. The Fresca 2 block coil type magnet will be operated at 1.9 K or 4.2 K and is designed to produce about 13 T. A 2D numerical thermal model was developed to determinate the temperature margin of the coil in working conditions and the appropriate cool-down scenario. The temperature margin, which is DTmarge=5.8 K at 1.9 K and DTmarge=3.5 K at 4.2 K, was investigated in steady state condition with the AC losses due to field ramp rate as input heat generation. Several cool-down scenarios were examined in order to minimize the temperature difference and therefore reducing the mechanical constraints within the structure. The paper presents the numerical model, the assumptions taken for the calculations and several results of the simulation for the cool-down and temperature distributions due to seve...

  5. Development of high field magnets at the National Research Institute for Metals. Kinzoku zairyo gijutsu kenkyusho ni okeru kojikai magnet gun no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kiyoshi, T.; Inoue, K.; Maeda, H. (National Research Inst. for Metals, Tsukuba (Japan))

    1993-06-20

    Sinece 1988, the Scince and Technology Agency has initiated the superconductor multicore project, which has a purpose of the versatile study on the high temperature superconducting materials of the oxide series. The National Research Institute for Metals is in charge of 5 cores out of them, and in the performance evaluation core which is one of them, the development of each kind of the high field magnets is being advanced for evaluating the characteristics under the high magnetic field. As the magnets, including the 40T class hybrid magnet which generates the steady state magnetic field of 40T, the superconducting magnet of 20T with a large diameter which generates the magnetic field over 20T with a superconductor, the condenser bank system for the pulse magnet to generate the pulse magnetic field up to 80T, and the ultra-precise magnet system which generates the magnetic field with a high uniformity will be consolidated. Keeping pace with a removal of the National Research Institute for Metals to Tsukuba, the construction of the strong magnetic field station is being advanced in the Sakura area. These several kinds of magnets are scheduled to be used in turn for the international joint study. 33 refs., 5 figs., 4 tabs.

  6. Genetic dissection of the mouse brain using high-field magnetic resonance microscopy.

    Science.gov (United States)

    Badea, A; Johnson, G A; Williams, R W

    2009-05-01

    Magnetic resonance (MR) imaging has demonstrated that variation in brain structure is associated with differences in behavior and disease state. However, it has rarely been practical to prospectively test causal models that link anatomical and functional differences in humans. In the present study we have combined classical mouse genetics with high-field MR to systematically explore and test such structure-functional relations across multiple brain regions. We segmented 33 regions in two parental strains-C57BL/6J (B) and DBA/2J (D)-and in nine BXD recombinant inbred strains. All strains have been studied extensively for more than 20 years using a battery of genetic, functional, anatomical, and behavioral assays. We compared levels of variation within and between strains and sexes, by region, and by system. Average within-strain variation had a coefficient of variation (CV) of 1.6% for the whole brain; while the CV ranged from 2.3 to 3.6% for olfactory bulbs, cortex and cerebellum, and up to approximately 18% for septum and laterodorsal thalamic nucleus. Variation among strain averages ranged from 6.7% for cerebellum, 7.6% for whole brain, 9.0% for cortex, up to approximately 26% for the ventricles, laterodorsal thalamic nucleus, and the interpeduncular nucleus. Heritabilities averaged 0.60+/-0.18. Sex differences were not significant with the possible (and unexpected) exception of the pons ( approximately 20% larger in males). A correlation matrix of regional volumes revealed high correlations among functionally related parts of the CNS (e.g., components of the limbic system), and several high correlations between regions that are not anatomically connected, but that may nonetheless be functionally or genetically coupled.

  7. Oxypnictide SmFeAs(O,F) superconductor: a candidate for high-field magnet applications.

    Science.gov (United States)

    Iida, Kazumasa; Hänisch, Jens; Tarantini, Chiara; Kurth, Fritz; Jaroszynski, Jan; Ueda, Shinya; Naito, Michio; Ichinose, Ataru; Tsukada, Ichiro; Reich, Elke; Grinenko, Vadim; Schultz, Ludwig; Holzapfel, Bernhard

    2013-01-01

    The recently discovered oxypnictide superconductor SmFeAs(O,F) is the most attractive material among the Fe-based superconductors due to its highest transition temperature of 56 K and potential for high-field performance. In order to exploit this new material for superconducting applications, the knowledge and understanding of its electro-magnetic properties are needed. Recent success in fabricating epitaxial SmFeAs(O,F) thin films opens a great opportunity to explore their transport properties. Here we report on a high critical current density of over 10(5) A/cm(2) at 45 T and 4.2 K for both main field orientations, feature favourable for high-field magnet applications. Additionally, by investigating the pinning properties, we observed a dimensional crossover between the superconducting coherence length and the FeAs interlayer distance at 30-40 K, indicative of a possible intrinsic Josephson junction in SmFeAs(O,F) at low temperatures that can be employed in electronics applications such as a terahertz radiation source and a superconducting Qubit.

  8. Cost Effective Open Geometry HTS MRI System amended to BSCCO 2212 Wire for High Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Kennth Marken

    2006-08-11

    the project start and that date a substantial shift in the MRI marketplace occurred, with rapid growth for systems at higher fields (1.5 T and above) and a consequent decline in the low field market (<1.0 T). While the project aim appeared technically attainable at that time, the conclusion was reached that the system and market economics do not warrant additional investment. The program was redirected to develop BSCCO 2212 multifilament wire development for high field superconducting magnets for NMR and other scientific research upon an agreement between DOE and Oxford Instruments, Superconducting Technology. The work t took place between September, 2004 and the project end in early 2006 was focused on 2212 multifilamentary wire. This report summarizes the technical achievements both in 2212 dip coated for an HTS MRI system and in BSCCO 2212 multifilamentary wire for high field magnets.

  9. Cost Effective Open Geometry HTS MRI System amended to BSCCO 2212 Wire for High Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Kennth Marken

    2006-08-11

    the project start and that date a substantial shift in the MRI marketplace occurred, with rapid growth for systems at higher fields (1.5 T and above) and a consequent decline in the low field market (<1.0 T). While the project aim appeared technically attainable at that time, the conclusion was reached that the system and market economics do not warrant additional investment. The program was redirected to develop BSCCO 2212 multifilament wire development for high field superconducting magnets for NMR and other scientific research upon an agreement between DOE and Oxford Instruments, Superconducting Technology. The work t took place between September, 2004 and the project end in early 2006 was focused on 2212 multifilamentary wire. This report summarizes the technical achievements both in 2212 dip coated for an HTS MRI system and in BSCCO 2212 multifilamentary wire for high field magnets.

  10. ADVANCED MAGNETIC RESONANCE IMAGING OF CEREBRAL CAVERNOUS MALFORMATIONS: I. HIGH FIELD IMAGING OF EXCISED HUMAN LESIONS

    Science.gov (United States)

    Shenkar, Robert; Venkatasubramanian, Palamadai N.; Zhao, Jin-cheng; Batjer, H. Hunt; Wyrwicz, Alice M.; Awad, Issam A.

    2008-01-01

    Objectives We hypothesized that structural details would be revealed in cerebral cavernous malformations (CCMs) through the use of high field magnetic resonance (MR) and confocal microscopy, which have not been described previously. The structural details of CCMs excised from human patients were sought by examination with high field MR imaging, and correlated with confocal microscopy of the same specimens. Novel features of CCM structure are outlined, including methodological limitations, venues for future research and possible clinical implications. Methods CCM lesions excised from four patients were fixed in 2% paraformaldehyde and subjected to high resolution MR imaging at 9.4 or 14.1 Tesla by spin-echo and gradient recalled echo methods. Histological validation of angioarchitecture was conducted on thick sections of CCM lesions using fluorescent probes to endothelium under confocal microscopy. Results Images of excised human CCM lesions were acquired with proton density-weighted, T1-weighted, T2-weighted spin echo and T2*-weighted gradient-recalled echo MR. These images revealed large “bland” regions with thin walled caverns, and “honeycombed” regions with notable capillary proliferation and smaller caverns surrounding larger caverns. Proliferating capillaries and caverns of various sizes were also associated with the wall of apparent larger blood vessels in the lesions. Similar features were confirmed within thick sections of CCMs by confocal microscopy. MR relaxation times in different regions of interest suggested the presence of different states of blood breakdown products in areas with apparent angiogenic proliferative activity. Conclusions The high field MR imaging techniques demonstrate novel features of CCM angioarchitecture, visible at near histological resolution, including regions with apparently different biologic activity. These preliminary observations will motivate future research, correlating lesion biologic and clinical activity with

  11. Tunable High-Field Magnetization in Strongly Exchange-Coupled Freestanding Co/CoO Core/Shell Coaxial Nanowires.

    Science.gov (United States)

    Salazar-Alvarez, German; Geshev, Julian; Agramunt-Puig, Sebastià; Navau, Carles; Sanchez, Alvaro; Sort, Jordi; Nogués, Josep

    2016-08-31

    The exchange bias properties of Co/CoO coaxial core/shell nanowires were investigated with cooling and applied fields perpendicular to the wire axis. This configuration leads to unexpected exchange-bias effects. First, the magnetization value at high fields is found to depend on the field-cooling conditions. This effect arises from the competition between the magnetic anisotropy and the Zeeman energies for cooling fields perpendicular to the wire axis. This allows imprinting predefined magnetization states to the antiferromagnetic (AFM) shell, as corroborated by micromagnetic simulations. Second, the system exhibits a high-field magnetic irreversibility, leading to open hysteresis loops attributed to the AFM easy axis reorientation during the reversal (effect similar to athermal training). A distinct way to manipulate the high-field magnetization in exchange-biased systems, beyond the archetypical effects, was thus experimentally and theoretically demonstrated.

  12. Costs of high-field superconducting strands for particle accelerator magnets

    CERN Document Server

    Cooley, L D; Scanlan, R M; 10.1088/0953-2048/18/4/R01

    2005-01-01

    The costs of superconducting magnet strands are compared by calculating a 'production scaling factor' P that relates purchase data to the cost of raw materials. Using a consistent method, we normalize for different conductor geometries and strand diameters to arrive at cost indices in $ kg/sup -1/, $ m/sup -1/, and $ kA/sup -1/ m/sup -1/. Analyses of Nb47Ti conductors taken from the past 25 years of high-field magnet projects reveal that the price of raw materials and, to a lesser extent, finished strands, have tracked the price of niobium pentoxide. Performance gains during the 1980s produced $ kA /sup -1/ m/sup -1/ indices that fell with time ahead of strand cost in $ m/sup -1/, a situation that may reflect the present status of Nb /sub 3/Sn magnet conductors. Analyses of present materials show that P decreases systematically with billet mass. While production strands in 200-500 kg billets have costs ~3 times the cost of raw materials, the 20-50 kg billet size for internal-tin Nb/sub 3/Sn composites drives ...

  13. Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques

    Directory of Open Access Journals (Sweden)

    Shaffer Jean M

    2010-05-01

    Full Text Available Abstract Background The assessment of arterial stiffness is increasingly used for evaluating patients with different cardiovascular diseases as the mechanical properties of major arteries are often altered. Aortic stiffness can be noninvasively estimated by measuring pulse wave velocity (PWV. Several methods have been proposed for measuring PWV using velocity-encoded cardiovascular magnetic resonance (CMR, including transit-time (TT, flow-area (QA, and cross-correlation (XC methods. However, assessment and comparison of these techniques at high field strength has not yet been performed. In this work, the TT, QA, and XC techniques were clinically tested at 3 Tesla and compared to each other. Methods Fifty cardiovascular patients and six volunteers were scanned to acquire the necessary images. The six volunteer scans were performed twice to test inter-scan reproducibility. Patient images were analyzed using the TT, XC, and QA methods to determine PWV. Two observers analyzed the images to determine inter-observer and intra-observer variabilities. The PWV measurements by the three methods were compared to each other to test inter-method variability. To illustrate the importance of PWV using CMR, the degree of aortic stiffness was assessed using PWV and related to LV dysfunction in five patients with diastolic heart failure patients and five matched volunteers. Results The inter-observer and intra-observer variability results showed no bias between the different techniques. The TT and XC results were more reproducible than the QA; the mean (SD inter-observer/intra-observer PWV differences were -0.12(1.3/-0.04(0.4 for TT, 0.2(1.3/0.09(0.9 for XC, and 0.6(1.6/0.2(1.4 m/s for QA methods, respectively. The correlation coefficients (r for the inter-observer/intra-observer comparisons were 0.94/0.99, 0.88/0.94, and 0.83/0.92 for the TT, XC, and QA methods, respectively. The inter-scan reproducibility results showed low variability between the repeated

  14. Shrink Tube Insulation Apparatus for Rebco Superconducting Tapes for Use in High Field Magnets

    CERN Document Server

    Whittington, Andrew

    An increasing number of applications require the use of high temperature superconductors (HTS) such as (RE=Rare Earth) Ba2Cu3O7-x (REBCO) coated conductors [1]. HTS conductors show particularly great potential for high field magnets applications [1] due to their high upper critical fields [2], But several groups have shown that REBCO coated conductors are prone to delamination failure [3] [4] [5]. Under relatively low transverse stress the HTS film separates from the substrate and the conductor degrades [6]. This is problematic due to high transverse stresses that occur in fully epoxy impregnated solenoids wound with this conductor. Application of thin walled heat shrink tubing introduces a weak plane around the conductor, preventing delamination degradation [7]. However, manual application of the shrink tubing is impractical, requiring three operators limited to insulating 100 m lengths or less of REBCO conductor. The high risk of damage to the conductor, also associated with this process, shows the need for...

  15. Magnetic susceptibility at high fields of Pb{sub 2}V{sub 3}O{sub 9}

    Energy Technology Data Exchange (ETDEWEB)

    Waki, T. [Department of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan)]. E-mail: twac@issp.u-tokyo.ac.jp; Tsujii, N. [National Institute for Materials Science, Sengen 1-2-1, Tsukuba 305-0047 (Japan); Itoh, Y. [Department of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Michioka, C. [Department of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Yoshimura, K. [Department of Chemistry, Graduate School of Science, Kyoto University, Kyoto 606-8502 (Japan); Suzuki, O. [National Institute for Materials Science, Sengen 1-2-1, Tsukuba 305-0047 (Japan); Kitazawa, H. [National Institute for Materials Science, Sengen 1-2-1, Tsukuba 305-0047 (Japan); Kido, G. [National Institute for Materials Science, Sengen 1-2-1, Tsukuba 305-0047 (Japan)

    2007-08-01

    The temperature dependence of magnetic susceptibility was measured for the S=12 quasi one dimensional antiferromagnet Pb{sub 2}V{sub 3}O{sub 9} under the steady magnetic field up to {mu}{sub 0}H=30 T. This material has alternating exchange interaction and a spin-gap at zero magnetic field. An anomaly of magnetic susceptibility indicating the field-induced antiferromagnetic long-range order was observed in high magnetic fields. The Neel temperature at high fields is much lower than the calculated value based on the standard mean-field theory of field-induced magnetic order.

  16. Slotted cage resonator for high-field magnetic resonance imaging of rodents

    Energy Technology Data Exchange (ETDEWEB)

    Marrufo, O; Vasquez, F; Solis, S E; Rodriguez, A O, E-mail: arog@xanum.uam.mx [Departamento de Ingenieria Electrica, Universidad Autonoma Metropolitana Iztapalapa, Mexico, DF 09340 (Mexico)

    2011-04-20

    A variation of the high-frequency cavity resonator coil was experimentally developed according to the theoretical frame proposed by Mansfield in 1990. Circular slots were used instead of cavities to form the coil endplates and it was called the slotted cage resonator coil. The theoretical principles were validated via a coil equivalent circuit and also experimentally with a coil prototype. The radio frequency magnetic field, B1, produced by several coil configurations was numerically simulated using the finite-element approach to investigate their performances. A transceiver coil, 8 cm long and 7.6 cm in diameter, and composed of 4 circular slots with a 15 mm diameter on both endplates, was built to operate at 300 MHz and quadrature driven. Experimental results obtained with the slotted cage resonator coil were presented and showed very good agreement with the theoretical expectations for the resonant frequency as a function of the coil dimensions and slots. A standard birdcage coil was also built for performance comparison purposes. Phantom images were then acquired to compute the signal-to-noise ratio of both coils showing an important improvement of the slotted cage coil over the birdcage coil. The whole-body images of the mouse were also obtained showing high-quality images. Volume resonator coils can be reliably built following the physical principles of the cavity resonator design for high-field magnetic resonance imaging applications of rodents.

  17. Inverse field-based approach for simultaneous B₁ mapping at high fields - a phantom based study.

    Science.gov (United States)

    Jin, Jin; Liu, Feng; Zuo, Zhentao; Xue, Rong; Li, Mingyan; Li, Yu; Weber, Ewald; Crozier, Stuart

    2012-04-01

    Based on computational electromagnetics and multi-level optimization, an inverse approach of attaining accurate mapping of both transmit and receive sensitivity of radiofrequency coils is presented. This paper extends our previous study of inverse methods of receptivity mapping at low fields, to allow accurate mapping of RF magnetic fields (B(1)) for high-field applications. Accurate receive sensitivity mapping is essential to image domain parallel imaging methods, such as sensitivity encoding (SENSE), to reconstruct high quality images. Accurate transmit sensitivity mapping will facilitate RF-shimming and parallel transmission techniques that directly address the RF inhomogeneity issue, arguably the most challenging issue of high-field magnetic resonance imaging (MRI). The inverse field-based approach proposed herein is based on computational electromagnetics and iterative optimization. It fits an experimental image to the numerically calculated signal intensity by iteratively optimizing the coil-subject geometry to better resemble the experiments. Accurate transmit and receive sensitivities are derived as intermediate results of the optimization process. The method is validated by imaging studies using homogeneous saline phantom at 7T. A simulation study at 300MHz demonstrates that the proposed method is able to obtain receptivity mapping with errors an order of magnitude less than that of the conventional method. The more accurate receptivity mapping and simultaneously obtained transmit sensitivity mapping could enable artefact-reduced and intensity-corrected image reconstructions. It is hoped that by providing an approach to the accurate mapping of both transmit and receive sensitivity, the proposed method will facilitate a range of applications in high-field MRI and parallel imaging. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. ECG-based gating in ultra high field cardiovascular magnetic resonance using an independent component analysis approach

    OpenAIRE

    Krug, Johannes W; Rose, Georg; Clifford, Gari D.; Oster, Julien

    2013-01-01

    Background In Cardiovascular Magnetic Resonance (CMR), the synchronization of image acquisition with heart motion is performed in clinical practice by processing the electrocardiogram (ECG). The ECG-based synchronization is well established for MR scanners with magnetic fields up to 3 T. However, this technique is prone to errors in ultra high field environments, e.g. in 7 T MR scanners as used in research applications. The high magnetic fields cause severe magnetohydrodynamic (MHD) effects w...

  19. High-field magnetic resonance imaging of the human temporal lobe

    Directory of Open Access Journals (Sweden)

    Luis M. Colon-Perez

    2015-01-01

    Conclusions: Fresh ex vivo MR imaging, along with tractography, revealed complex intra-temporal structural variation corresponding to neuronal cell body layers, dendritic fields, and axonal projection systems evident histologically. This is the first study to describe in detail the human temporal lobe structural organization using high-field MR imaging and tractography. By preserving the 3-dimensional structures of the hippocampus and surrounding structures, specific changes in anatomy may inform us about the changes that occur in TLE in relation to the disease process and structural underpinnings in epilepsy-related memory dysfunction.

  20. Retears of postoperative knee meniscus: findings on magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) by using low and high field magnets

    Energy Technology Data Exchange (ETDEWEB)

    Cardello, Paolo; Pofi, Enrico [Belcolle Hospital, Department of Radiodiagnostic, Viterbo (Italy); Gigli, Carlo; Voglino, Nicola [Belcolle Hospital, Division of Knee Surgery and Arthroscopy, Department of Orthopedics and Traumatology, Viterbo (Italy); Ricci, Alessandra; Chiatti, Leonardo [Belcolle Hospital, Department of Medical Physics, Viterbo (Italy)

    2009-02-15

    The purpose of this study was to determine the diagnostic performance of magnetic resonance (MR) obtained with intra-articular contrast medium in the evaluation of recurrent meniscal tears using low-field extremity-only and high-field whole-body magnets. Postoperative standard MR examinations and MR arthrographies of 95 knees were reviewed. Patients experiencing pain and disability after meniscal repair underwent standard MR and MR arthrography (Gadoterate meglumine 0.0025 mmol/ml) on both a 0.2-T and 1.5-T magnet. In 52 of 95 patients, second-look arthroscopy was performed; in the remaining 43 of 95 patients, clinical follow-up was used as the standard of reference. Sensitivity, specificity, positive and negative predictive values as well as accuracy of MRI/MR arthrographic signs as meniscal morphologic changes and the presence of contrast medium tracking into the tear at T1- and T2-weighted sequences in the detection of recurrent meniscal tears were determined. All MR and MR arthrograpic signs were sensitive in the detection of recurrent tears (range 80-91%). Abnormal meniscal morphology had low specificity [26% (13/50)] for both the 0.2-T and 1.5-T scanner, whereas accuracy was 55% (52/95) and 57% (54/95), respectively. The presence of contrast medium within the meniscus substance on T2-weighted images had higher value of specificity [84% (42/50)] and accuracy [84% (80/95)] by using low field strength magnet than by using high field strength magnet [74% (37/50) and 81% (77/95), respectively]. Whereas, the increased intrameniscal signal intensity extending to the meniscal surface at T1-weighted sequences after intra-articular contrast medium administration had lower specificity and accuracy on 0.2-T images [84% (42/50) and 82% (78/95), respectively] than on 1.5-T images [90% (45/50) and 88% (84/95), respectively]. A diagnosis of recurrent meniscal tear in a previously arthroscopically repaired meniscus can be made both on 0.2-T and 1.5-T magnets on the basis of

  1. Brain–heart interactions: challenges and opportunities with functional magnetic resonance imaging at ultra-high field

    Science.gov (United States)

    Raven, Erika P.; Duyn, Jeff H.

    2016-01-01

    Magnetic resonance imaging (MRI) at ultra-high field (UHF) strengths (7 T and above) offers unique opportunities for studying the human brain with increased spatial resolution, contrast and sensitivity. However, its reliability can be compromised by factors such as head motion, image distortion and non-neural fluctuations of the functional MRI signal. The objective of this review is to provide a critical discussion of the advantages and trade-offs associated with UHF imaging, focusing on the application to studying brain–heart interactions. We describe how UHF MRI may provide contrast and resolution benefits for measuring neural activity of regions involved in the control and mediation of autonomic processes, and in delineating such regions based on anatomical MRI contrast. Limitations arising from confounding signals are discussed, including challenges with distinguishing non-neural physiological effects from the neural signals of interest that reflect cardiorespiratory function. We also consider how recently developed data analysis techniques may be applied to high-field imaging data to uncover novel information about brain–heart interactions. PMID:27044994

  2. Brain-heart interactions: challenges and opportunities with functional magnetic resonance imaging at ultra-high field.

    Science.gov (United States)

    Chang, Catie; Raven, Erika P; Duyn, Jeff H

    2016-05-13

    Magnetic resonance imaging (MRI) at ultra-high field (UHF) strengths (7 T and above) offers unique opportunities for studying the human brain with increased spatial resolution, contrast and sensitivity. However, its reliability can be compromised by factors such as head motion, image distortion and non-neural fluctuations of the functional MRI signal. The objective of this review is to provide a critical discussion of the advantages and trade-offs associated with UHF imaging, focusing on the application to studying brain-heart interactions. We describe how UHF MRI may provide contrast and resolution benefits for measuring neural activity of regions involved in the control and mediation of autonomic processes, and in delineating such regions based on anatomical MRI contrast. Limitations arising from confounding signals are discussed, including challenges with distinguishing non-neural physiological effects from the neural signals of interest that reflect cardiorespiratory function. We also consider how recently developed data analysis techniques may be applied to high-field imaging data to uncover novel information about brain-heart interactions.

  3. Analysis of Uncertainties in Protection Heater Delay Time Measurements and Simulations in Nb$_{3}$Sn High-Field Accelerator Magnets

    CERN Document Server

    Salmi, Tiina; Marchevsky, Maxim; Bajas, Hugo; Felice, Helene; Stenvall, Antti

    2015-01-01

    The quench protection of superconducting high-field accelerator magnets is presently based on protection heaters, which are activated upon quench detection to accelerate the quench propagation within the winding. Estimations of the heater delay to initiate a normal zone in the coil are essential for the protection design. During the development of Nb3Sn magnets for the LHC luminosity upgrade, protection heater delays have been measured in several experiments, and a new computational tool CoHDA (Code for Heater Delay Analysis) has been developed for heater design. Several computational quench analyses suggest that the efficiency of the present heater technology is on the borderline of protecting the magnets. Quantifying the inevitable uncertainties related to the measured and simulated delays is therefore of pivotal importance. In this paper, we analyze the uncertainties in the heater delay measurements and simulations using data from five impregnated high-field Nb3Sn magnets with different heater geometries. ...

  4. High-field magnetization studies of spin-dimer behaviors on low-dimensional spin systems, LiCu2-xZnxO2 and FeTe3O7X (X = Cl, Br)

    Science.gov (United States)

    Her, J. L.; Hsu, H. C.; Matsuda, Y. H.; Kindo, K.; Chou, C. C.; Yang, H. D.; Berger, H.; Chou, F. C.

    2013-03-01

    Following our previous paper reporting enhancement of magnetic moment in powder Mn11Si19 (~30 microns in diameter), we report here on magnetic moment for smaller particles (~5 microns in diameter) at 5 K to 300 K. Apart from the larger particles case, magnetisation curves against field exhibit distinctive features of soft magnetic materials over the whole range of temperatures. We observed a sort of superparamagnetism in non-nanoparticles.

  5. Low and High Field Magnetic Resonance for in Vivo Analysis of Seeds

    Directory of Open Access Journals (Sweden)

    Thomas Neuberger

    2011-08-01

    Full Text Available Low field NMR has been successfully used for the evaluation of seed composition and quality, but largely only in crop species. We show here that 1.5T NMR provides a reliable means for analysing the seed lipid fraction present in a wide range of species, where both the seed size and lipid concentration differed by >10 fold. Little use of high field NMR has been made in seed research to date, even though it potentially offers many opportunities for studying seed development, metabolism and storage. Here we demonstrate how 17.5T and 20T NMR can be applied to image seed structure, and analyse lipid and metabolite distribution. We suggest that further technical developments in NMR/MRI will facilitate significant advances in our understanding of seed biology.

  6. Analysing radio-frequency coil arrays in high-field magnetic resonance imaging by the combined field integral equation method.

    Science.gov (United States)

    Wang, Shumin; Duyn, Jeff H

    2006-06-21

    We present the combined field integral equation (CFIE) method for analysing radio-frequency coil arrays in high-field magnetic resonance imaging (MRI). Three-dimensional models of coils and the human body were used to take into account the electromagnetic coupling. In the method of moments formulation, we applied triangular patches and the Rao-Wilton-Glisson basis functions to model arbitrarily shaped geometries. We first examined a rectangular loop coil to verify the CFIE method and also demonstrate its efficiency and accuracy. We then studied several eight-channel receive-only head coil arrays for 7.0 T SENSE functional MRI. Numerical results show that the signal dropout and the average SNR are two major concerns in SENSE coil array design. A good design should be a balance of these two factors.

  7. High field nuclear magnetic resonance in transition metal substituted BaFe{sub 2}As{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Garitezi, T. M., E-mail: thalesmg@ifi.unicamp.br; Lesseux, G. G.; Rosa, P. F. S.; Adriano, C.; Pagliuso, P. G.; Urbano, R. R. [Instituto de Física “Gleb Wataghin,” UNICAMP, Campinas, SP 13083-859 (Brazil); Reyes, A. P.; Kuhns, P. L. [National High Magnetic Field Laboratory, FSU, Tallahassee, Florida 32306-4005 (United States)

    2014-05-07

    We report high field {sup 75}As nuclear magnetic resonance (NMR) measurements on Co and Cu substituted BaFe{sub 2}As{sub 2} single crystals displaying same structural/magnetic transition T{sub 0}≃128  K. From our anisotropy studies in the paramagnetic state, we strikingly found virtually identical quadrupolar splitting and consequently the quadrupole frequency ν{sub Q}≃2.57(1)  MHz for both compounds, despite the claim that each Cu delivers 2 extra 3d electrons in BaFe{sub 2}As{sub 2} compared to Co substitution. These results allow us to conclude that a subtle change in the crystallographic structure, particularly in the Fe–As tetrahedra, must be the most probable tuning parameter to determine T{sub 0} in this class of superconductors rather than electronic doping. Furthermore, our NMR data around T{sub 0} suggest coexistence of tetragonal/paramagnetic and orthorhombic/antiferromagnetic phases between the structural and the spin density wave magnetic phase transitions, similarly to what was reported for K-doped BaFe{sub 2}As{sub 2} [Urbano et al., Phys. Rev. Lett. 105, 107001 (2010)].

  8. A design of novel type superconducting magnet for super-high field functional magnetic resonance imaging by using the harmonic analysis method of magnetic vector potentials

    Institute of Scientific and Technical Information of China (English)

    俎栋林; 郭华; 宋枭禹; 包尚联

    2002-01-01

    The approach of expanding the magnetic scalar potential in a series of Legendre polynomials is suitable for designing a conventional superconducting magnetic resonance imaging magnet of distributed solenoidal configuration. Whereas the approach of expanding the magnetic vector potential in associated Legendre harmonics is suitable for designing a single-solenoid magnet that has multiple tiers, in which each tier may have multiple layers with different winding lengths. A set of three equations to suppress some of the lowest higher-order harmonics is found. As an example, a 4T single-solenoid magnetic resonance imaging magnet with 4 × 6 layers of superconducting wires is de signed The degree of homogeneity in the 0.5m diameter sphere volume is better than 5.8 ppm. The same degree of homogeneity is retained after optimal integralization of turns in each correction layer. The ratio Bm/Bo in the single-solenoid magnet is 30%lower than that in the conventional six-solenoid magnet. This tolerates higher rated superconducting current in the coil. The Lorentz force of the coil in the single-solenoid system is also much lower than in the six-solenoid system. This novel type of magnet possesses significant advantage over conventional magnets, especially when used as a super-high field functional magnetic resonance imaging magnet.

  9. Endometrium evaluation with high-field (3-Tesla) magnetic resonance imaging in patients submitted to uterine leiomyoma embolization

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Monica Amadio Piazza [Post-graduation Program in Abdominal Imaging, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Nasser, Felipe [Intervention Radiology Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Zlotnik, Eduardo; Messina, Marcos de Lorenzo [Gynecology and Obstetrics Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil); Baroni, Ronaldo Hueb [Magnetic Resonance Unit, Imaging Department, Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2013-07-01

    To evaluate the endometrial alterations related to embolization of uterine arteries for the treatment of symptomatic uterine leiomyomatosis (pelvic pain and/or uterine bleeding) by means of high-field (3-Tesla) magnetic resonance. This is a longitudinal and prospective study that included 94 patients with a clinical and imaging diagnosis of symptomatic uterine leiomyomatosis, all of them treated by embolization of the uterine arteries. The patients were submitted to evaluations by high-field magnetic resonance of the pelvis before and 6 months after the procedure. Specific evaluations were made of the endometrium on the T2-weighted sequences, and on the T1-weighted sequences before and after the intravenous dynamic infusion of the paramagnetic contrast. In face of these measures, statistical analyses were performed using Student's t test for comparison of the results obtained before and after the procedure. An average increase of 20.9% was noted in the endometrial signal on T2-weighted images obtained after the uterine artery embolization procedure when compared to the pre-procedure evaluation (p=0.0004). In the images obtained with the intravenous infusion of paramagnetic contrast, an average increase of 18.7% was noted in the post-embolization intensity of the endometrial signal, compared to the pre-embolization measure (p<0.035). After embolization of the uterine arteries, there was a significant increase of the endometrial signal on the T2-weighted images and on the post-contrast images, inferring possible edema and increased endometrial flow. Future studies are needed to assess the clinical impact of these findings.

  10. The role of high-field magnetic resonance imaging in parkinsonian disorders

    DEFF Research Database (Denmark)

    Lehéricy, Stephane; Vaillancourt, David E; Seppi, Klaus

    2017-01-01

    Historically, magnetic resonance imaging (MRI) has contributed little to the study of Parkinson's disease (PD), but modern MRI approaches have unveiled several complementary markers that are useful for research and clinical applications. Iron- and neuromelanin-sensitive MRI detect qualitative cha...

  11. Fiber optic quench detection via optimized Rayleigh Scattering in high-field YBCO accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Flanagan, Gene [North Carolina State Univ., Raleigh, NC (United States)

    2016-02-17

    Yttrium barium copper oxide (YBCO) coated conductors are known for their ability to operate in the superconducting state at relatively high temperatures, even above the boiling point of liquid nitrogen (77 K). When these same conductors are operated at lower temperatures, they are able to operate in much higher magnetic fields than traditional superconductors like NiTi or Nb3Sn. Thus, YBCO superconducting magnets are one of the primary options for generating the high magnetic fields needed for future high energy physics devices. Due to slow quench propagation, quench detection remains one of the primary limitations to YBCO magnets. Fiber optic sensing, based upon Rayleigh scattering, has the potential for spatial resolution approaching the wavelength of light, or very fast temporal resolution at low spatial resolution, and a continuum of combinations in between. This project has studied, theoretically and experimentally, YBCO magnets and Rayleigh scattering quench detection systems to demonstrate feasibility of the systems for YBCO quench protection systems. Under this grant an experimentally validated 3D quench propagation model was used to accurately define the acceptable range of spatial and temporal resolutions for effective quench detection in YBCO magnets and to evaluate present-day and potentially improved YBCO conductors. The data volume and speed requirements for quench detection via Rayleigh scattering required the development of a high performance fiber optic based quench detection/data acquisition system and its integration with an existing voltage tap/thermo-couple based system. In this project, optical fibers are tightly co-wound into YBCO magnet coils, with the fiber on top of the conductor as turn-to-turn insulation. Local changes in the temperature or strain of the conductor are sensed by the optical fiber, which is in close thermal and mechanical contact with the conductor. Intrinsic imperfections in the fiber reflect Rayleigh

  12. A titanium dioxide filled toroidal coil for magnetic resonance imaging at high field

    Science.gov (United States)

    Butterworth, Edward J.

    1999-09-01

    This study demonstrates the advantages of filling the resonating cavity of a radio frequency NMR coil with a substance that more closely matches the dielectric properties of human tissue. The chosen design is a toroidal RF coil of reduced aspect ratio, and the dielectric material of choice is powdered titanium dioxide. RF coil performance is limited significantly by the dielectric discontinuity and consequent wavelength discontinuity between the air-filled cavity and human tissue. Filling the coil with titanium dioxide (with a published relative dielectric constant of 114 for randomly oriented rutile crystals and a measured dielectric constant under operating conditions of 70) alters its electromagnetic properties in a way which approximates human tissue (most of which has a dielectric constant between 50 and 70), without introducing spurious magnetic effects. In particular, brain NMR can benefit from these advantages. Analytic expressions for the electric and magnetic fields within the coil are derived here. The physical and electromagnetic parameters of the coil are developed with reference to these computations. The redesigned and filled resonator focuses the magnetic field lines, producing a more uniform B1 field as compared with the unfilled coil, with reduced power requirements. The filled coil has a well-defined imaging zone, in which the magnetic field is relatively uniform and homogeneous. The Q of the coil is significantly higher than that of conventional designs and is not significantly reduced by loading. Test results and images are presented showing these effects.

  13. A feasibility study of high-strength Bi-2223 conductor for high-field solenoids

    Science.gov (United States)

    Godeke, A.; Abraimov, D. V.; Arroyo, E.; Barret, N.; Bird, M. D.; Francis, A.; Jaroszynski, J.; Kurteva, D. V.; Markiewicz, W. D.; Marks, E. L.; Marshall, W. S.; McRae, D. M.; Noyes, P. D.; Pereira, R. C. P.; Viouchkov, Y. L.; Walsh, R. P.; White, J. M.

    2017-03-01

    We performed a feasibility study on a high-strength Bi{}2-xPb x Sr2Ca2Cu3O{}10-x(Bi-2223) tape conductor for high-field solenoid applications. The investigated conductor, DI-BSCCO Type HT-XX, is a pre-production version of Type HT-NX, which has recently become available from Sumitomo Electric Industries. It is based on their DI-BSCCO Type H tape, but laminated with a high-strength Ni-alloy. We used stress–strain characterizations, single- and double-bend tests, easy- and hard-way bent coil-turns at various radii, straight and helical samples in up to 31.2 T background field, and small 20-turn coils in up to 17 T background field to systematically determine the electro-mechanical limits in magnet-relevant conditions. In longitudinal tensile tests at 77 K, we found critical stress- and strain-levels of 516 MPa and 0.57%, respectively. In three decidedly different experiments we detected an amplification of the allowable strain with a combination of pure bending and Lorentz loading to ≥slant 0.92 % (calculated elastically at the outer tape edge). This significant strain level, and the fact that it is multi-filamentary conductor and available in the reacted and insulated state, makes DI-BSCCO HT-NX highly suitable for very high-field solenoids, for which high current densities and therefore high loads are required to retain manageable magnet dimensions.

  14. Safety of metallic surgical clips in patients undergoing high-field-strength magnetic resonance imaging.

    Science.gov (United States)

    Gold, J P; Pulsinelli, W; Winchester, P; Brill, P W; Jacewicz, M; Isom, O W

    1989-11-01

    Use of metallic clips with ferromagnetic properties in patients undergoing a large variety of surgical procedures, and in particular, in coronary artery and other vascular reconstructions, has become increasingly popular. The safety of these commonly used surgical clips when subjected to high-intensity diagnostic magnetic resonance imaging fields is still debated. Commonly used hemostatic metallic clips manufactured by the Weck and US Surgical Corporations were tested in an in vitro system to assess their safety with regard to migration and displacement. The two tested hemostatic metallic clips proved safe and did not migrate or become dislodged when they underwent magnetic resonance imaging scans. This is in direct contrast to multiple cerebral aneurysm clips, also tested, which have highly ferromagnetic properties and were previously shown to migrate with disastrous results in patients undergoing diagnostic magnetic resonance imaging scans. This study supports the continued widespread use of small metallic hemostatic clips in the myriad of procedures in which they are presently used and illustrates the need for methods of evaluating such devices before they are clinically implanted.

  15. High field magnetic behavior in Boron doped Fe2VAl Heusler alloys

    Science.gov (United States)

    Venkatesh, Ch.; Vasundhara, M.; Srinivas, V.; Rao, V. V.

    2016-11-01

    We have investigated the magnetic behavior of Fe2VAl1-xBx (x=0, 0.03, 0.06 and 0.1) alloys under high temperature and high magnetic field conditions separately. Although, the low temperature DC magnetization data for the alloys above x>0 show clear magnetic transitions, the zero field cooled (ZFC) and field cooled (FC) curves indicate the presence of spin cluster like features. Further, critical exponent (γ) deduced from the initial susceptibility above the Tc, does not agree with standard models derived for 3 dimensional long range magnetic systems. The deviation in γ values are consistent with the short range magnetic nature of these alloys. We further extend the analysis of magnetic behavior by carrying the magnetization measurements at high temperatures and high magnetic fields distinctly. We mainly emphasize the following observations; (i) The magnetic hysteresis loops show sharp upturns at lower fields even at 900 K for all the alloys. (ii) High temperature inverse susceptibility do not overlap until T=900 K, indicating the persistent short range magnetic correlations even at high temperatures. (iii) The Arrott's plot of magnetization data shows spontaneous moment (MS) for the x=0 alloy at higher magnetic fields which is absent at lower fields (magnetic heterogeneous phases which are not detected from the X-ray diffraction method.

  16. Safety implications of high-field MRI: actuation of endogenous magnetic iron oxides in the human body.

    Directory of Open Access Journals (Sweden)

    Jon Dobson

    Full Text Available BACKGROUND: Magnetic Resonance Imaging scanners have become ubiquitous in hospitals and high-field systems (greater than 3 Tesla are becoming increasingly common. In light of recent European Union moves to limit high-field exposure for those working with MRI scanners, we have evaluated the potential for detrimental cellular effects via nanomagnetic actuation of endogenous iron oxides in the body. METHODOLOGY: Theoretical models and experimental data on the composition and magnetic properties of endogenous iron oxides in human tissue were used to analyze the forces on iron oxide particles. PRINCIPAL FINDING AND CONCLUSIONS: Results show that, even at 9.4 Tesla, forces on these particles are unlikely to disrupt normal cellular function via nanomagnetic actuation.

  17. Scoping study for compact high-field superconducting net energy tokamaks

    Science.gov (United States)

    Mumgaard, R. T.; Greenwald, M.; Freidberg, J. P.; Wolfe, S. M.; Hartwig, Z. S.; Brunner, D.; Sorbom, B. N.; Whyte, D. G.

    2016-10-01

    The continued development and commercialization of high temperature superconductors (HTS) may enable the construction of compact, net-energy tokamaks. HTS, in contrast to present generation low temperature superconductors, offers improved performance in high magnetic fields, higher current density, stronger materials, higher temperature operation, and simplified assembly. Using HTS along with community-consensus confinement physics (H98 =1) may make it possible to achieve net-energy (Q>1) or burning plasma conditions (Q>5) in DIII-D or ASDEX-U sized, conventional aspect ratio tokamaks. It is shown that, by operating at high plasma current and density enabled by the high magnetic field (B>10T), the required triple products may be achieved at plasma volumes under 20m3, major radii under 2m, with external heating powers under 40MW. This is at the scale of existing devices operated by laboratories, universities and companies. The trade-offs in the core heating, divertor heat exhaust, sustainment, stability, and proximity to known plasma physics limits are discussed in the context of the present tokamak experience base and the requirements for future devices. The resulting HTS-based design space is compared and contrasted to previous studies on high-field copper experiments with similar missions. The physics exploration conducted with such HTS devices could decrease the real and perceived risks of ITER exploitation, and aid in quickly developing commercially-applicable tokamak pilot plants and reactors.

  18. High-field magnetic resonance imaging of brain iron: birth of a biomarker?

    Science.gov (United States)

    Schenck, John F; Zimmerman, Earl A

    2004-11-01

    The brain has an unusually high concentration of iron, which is distributed in an unusual pattern unlike that in any other organ. The physiological role of this iron and the reasons for this pattern of distribution are not yet understood. There is increasing evidence that several neurodegenerative diseases are associated with altered brain iron metabolism. Understanding these dysmetabolic conditions may provide important information for their diagnosis and treatment. For many years the iron distribution in the human brain could be studied effectively only under postmortem conditions. This situation was changed dramatically by the finding that T2-weighted MR imaging at high field strength (initially 1.5 T) appears to demonstrate the pattern of iron distribution in normal brains and that this imaging technique can detect changes in brain iron concentrations associated with disease states. Up to the present time this imaging capability has been utilized in many research applications but it has not yet been widely applied in the routine diagnosis and management of neurodegenerative disorders. However, recent advances in the basic science of brain iron metabolism, the clinical understanding of neurodegenerative diseases and in MRI technology, particularly in the availability of clinical scanners operating at the higher field strength of 3 T, suggest that iron-dependent MR imaging may soon provide biomarkers capable of characterizing the presence and progression of important neurological disorders. Such biomarkers may be of crucial assistance in the development and utilization of effective new therapies for Alzheimer's and Parkinson's diseases, multiple sclerosis and other iron-related CNS disorders which are difficult to diagnose and treat.

  19. [Orbital vasculonervous network and orbital surgical compartments by high field magnetic resonance].

    Science.gov (United States)

    Hernández González, L C; Suárez Suárez, E; Dos Santos Bernardo, V; Junceda Moreno, J; Recio Rodríguez, M; Martínez De Vega, V; Viaño López, J

    2003-10-01

    To elucidate the possibilities and indications of high-resolution magnetic resonance imaging (MRI) in the study of the orbit and its contents. Orbital anatomy was studied in sliced specimens of fifteen fresh frozen cadavers and the results were compared with those obtained in thirty asymptomatic subjects who underwent a magnetic resonance with 1.5 Tesla equipment. The information obtained was used to interpret the findings in twenty-two patients with various orbital diseases. High-resolution MRI allows visualization of structures difficult to assess previously, like the cerebrospinal fluid (CSF) surrounding the optic nerve, the complete intraorbital route and the exit of the third cranial nerve, the ophthalmic artery and the intraorbital relationships of the sixth cranial nerve, which can be clearly differentiated from the lateral rectus muscle. High-resolution MRI is a very useful tool for the study of the orbit and its content. It provides accurate diagnoses through non-invasive procedures and facilitates the planning of the surgical approaches by improving the visualization of pathologic orbital structures. lcarlos@correo.uniovi.es

  20. The connective tissue and ligaments of the distal interphalangeal joint: a review and investigation using ultra-high field 16.4 Tesla magnetic resonance imaging.

    Science.gov (United States)

    Slattery, D; Aland, C; Durbridge, G; Cowin, G

    2014-05-01

    This study reviews the literature on the anatomy of the connective tissues surrounding the distal interphalangeal joint and further characterizes the three-dimensional relationships of these structures with ultra-high field magnetic resonance imaging. Ten cadaver fingers, fixed in a solution of 5% agar and 4% formalin, were imaged utilising an ultrashield 16.4 Tesla ultra-high field magnetic resonance imaging, yielding a total of 4000 images. Images were analysed using Osirix™ (version 5.5.1 32 bit edition) for three-dimensional reconstruction. We found numerous conflicting descriptions of the connective tissue structures around the distal interphalangeal joint. Based upon our literature review and imaging studies we have defined precisely Cleland's ligaments, the oblique proximal septum, Grayson's ligaments, the dorsal plate, and the interosseous ligaments of the distal interphalangeal joint.

  1. Functional magnetic resonance imaging with ultra-high fields; Funktionelle Magnetresonanztomographie bei ultrahohen Feldern

    Energy Technology Data Exchange (ETDEWEB)

    Windischberger, C.; Schoepf, V.; Sladky, R.; Moser, E. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Wien (Austria); Medizinische Universitaet Wien, Zentrum fuer Medizinische Physik und Biomedizinische Technik, Wien (Austria); Fischmeister, F.P.S. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-MR, Wien (Austria); Universitaet Wien, Fakultaet fuer Psychologie, Wien (Austria)

    2010-02-15

    Functional magnetic resonance imaging (fMRI) is currently the primary method for non-invasive functional localization in the brain. With the emergence of MR systems with field strengths of 4 Tesla and above, neuronal activation may be studied with unprecedented accuracy. In this article we present different approaches to use the improved sensitivity and specificity for expanding current fMRT resolution limits in space and time based on several 7 Tesla studies. In addition to the challenges that arise with ultra-high magnetic fields possible solutions will be discussed. (orig.) [German] Die funktionelle Magnetresonanztomographie (fMRT) stellt zurzeit die wichtigste Methode zur nichtinvasiven Funktionslokalisation im Gehirn dar. Mit der Verfuegbarkeit von MRT-Geraeten mit Magnetfeldstaerken von 4 Tesla (T) und darueber ergeben sich neue Moeglichkeiten, mittels fMRT die neuronale Aktivitaet in bislang unerreichter Genauigkeit zu untersuchen. In diesem Artikel zeigen wir anhand mehrerer Studien bei 7 T, in wieweit die Zugewinne an Sensitivitaet und Spezifitaet verwendet werden koennen, um die bisherigen Grenzen der fMRT-Aufloesung in raeumlicher und zeitlicher Hinsicht auszuweiten. Die neuen Herausforderungen, die mit dem Schritt zu ultrahohen Magnetfeldern einhergehen, werden dabei ebenso diskutiert wie moegliche Ansaetze zu deren Loesung. (orig.)

  2. Functionality of veterinary identification microchips following low- (0.5 tesla) and high-field (3 tesla) magnetic resonance imaging.

    Science.gov (United States)

    Piesnack, Susann; Frame, Mairi E; Oechtering, Gerhard; Ludewig, Eberhard

    2013-01-01

    The ability to read patient identification microchips relies on the use of radiofrequency pulses. Since radiofrequency pulses also form an integral part of the magnetic resonance imaging (MRI) process, the possibility of loss of microchip function during MRI scanning is of concern. Previous clinical trials have shown microchip function to be unaffected by MR imaging using a field strength of 1 Tesla and 1.5. As veterinary MRI scanners range widely in field strength, this study was devised to determine whether exposure to lower or higher field strengths than 1 Tesla would affect the function of different types of microchip. In a phantom study, a total of 300 International Standards Organisation (ISO)-approved microchips (100 each of three different types: ISO FDX-B 1.4 × 9 mm, ISO FDX-B 2.12 × 12 mm, ISO HDX 3.8 × 23 mm) were tested in a low field (0.5) and a high field scanner (3.0 Tesla). A total of 50 microchips of each type were tested in each scanner. The phantom was composed of a fluid-filled freezer pack onto which a plastic pillow and a cardboard strip with affixed microchips were positioned. Following an MRI scan protocol simulating a head study, all of the microchips were accurately readable. Neither 0.5 nor 3 Tesla imaging affected microchip function in this study. © 2013 Veterinary Radiology & Ultrasound.

  3. Zero-field nuclear magnetic resonance in high field by modulated rf sequences.

    Science.gov (United States)

    Nishiyama, Yusuke; Yamazaki, Toshio

    2007-04-07

    The authors propose a novel approach to design and evaluate sequences for zero-field NMR spectra in high field (ZFHF) by using amplitude and phase modulated rf sequences. ZFHF provide sharp peaks for the dipolar interaction between two nuclear spins even if the orientation of the molecules is distributed. The internuclear distance r can be directly obtained from the peak position which is proportional to r-3. Numerous ZFHF sequences are obtained. A sequence is selected from them by the systematic evaluation of the sequences. The new ZFHF sequence is less affected by chemical shift anisotropy (CSA) than the previous sequences; the sequence can be used for systems with large CSA such as a dipolar coupled 13C-pair system under realistically high field. 13C ZFHF spectra of 13C2 diammonium succinate and 13C2 diammonium oxalate were observed under the 9.4 T field.

  4. Estimation of the Required Amount of Superconductors for High-field Accelerator Dipole Magnets

    CERN Document Server

    Schwerg, N

    2007-01-01

    The coil size and the corresponding amount of superconducting material that is used during the design process of a magnet cross-section have direct impacts on the overall magnet cost. It is therefore of interest to estimate the minimum amount of conductors needed to reach the defined field strength before a detailed design process starts. Equally, it is useful to evaluate the efficiency of a given design by calculating the amount of superconducting cables that are used to reach the envisaged main field by simple rule. To this purpose, the minimum amount of conductors for the construction of a dipole of given main field strength and aperture size is estimated taking the actual critical current density of the used strands into account. Characteristic curves applicable for the NED Nb3Sn strand specification are given and some of the recently studied different dipole configurations are compared. Based on these results, it is shown how the required amount of conductors changes due to the iron yoke contribution and...

  5. Quench absorption coils: a quench protection concept for high-field superconducting accelerator magnets

    Science.gov (United States)

    Mentink, M.; Salmi, T.

    2017-06-01

    A quench protection concept based on coupled secondary coils is studied for inductively transferring energy out of a quenching superconducting dipole and thus limiting the peak hotspot temperature. So-called ‘quench absorption coils’ are placed in close proximity to the superconducting coils and are connected in series with a diode for the purpose of preventing current transformation during regular operation. During a quench, current is then transformed into the quench absorption coils so that a significant fraction of the stored magnetic energy is dissipated in the these coils. Numerical calculations are performed to determine the impact of such a concept and to evaluate the dimensions of the quench absorption coils needed to obtain significant benefits. A previously constructed 15 T Nb3Sn block coil is taken as a reference layout. Finite-element calculations are used to determine the combined inductive and thermal response of this system and these calculations are validated with a numerical model using an adiabatic approximation. The calculation results indicate that during a quench the presence of the quench absorption coils reduces the energy dissipated in the superconducting coils by 45% and reduces the hotspot temperature by over 100 K. In addition, the peak resistive voltage over the superconducting coils is significantly reduced. This suggests that this concept may prove useful for magnet designs in which the hotspot temperature is a design driver.

  6. High field (9.4 Tesla) magnetic resonance imaging of cortical grey matter lesions in multiple sclerosis.

    Science.gov (United States)

    Schmierer, Klaus; Parkes, Harold G; So, Po-Wah; An, Shu F; Brandner, Sebastian; Ordidge, Roger J; Yousry, Tarek A; Miller, David H

    2010-03-01

    .9; SD = 5 versus 22.6 ms; SD = 4.7; P < 0.01). Associations were detected between phosphorylated neurofilament and myelin basic protein (r = 0.58, P < 0.01), myelin basic protein and T(2) (r = -0.59, P < 0.01), and neuronal density and T(1) (r = -0.57, P < 0.01). All indices correlated with duration of tissue fixation, however, including the latter in the analysis did not fundamentally affect the associations described. Our data show that T(2)-weighted magnetic resonance imaging at 9.4 T enables detection of cortical grey matter lesion in post-mortem multiple sclerosis brain. The quantitative associations suggest that in cortical grey matter T(1) may be a predictor of neuronal density, and T(2) of myelin content (and-secondarily-axons). Successful translation of these results into in vivo studies using high field magnetic resonance imaging (e.g. 3 T and 7 T) will improve the assessment of cortical pathology and thereby have an impact on the diagnosis and natural history studies of patients with multiple sclerosis, as well as clinical trial designs for putative treatments to prevent cortical demyelination and neuronal loss.

  7. The issues and tentative solutions for contrast-enhanced magnetic resonance imaging at ultra-high field strength.

    Science.gov (United States)

    Fries, Peter; Morelli, John N; Lux, Francois; Tillement, Olivier; Schneider, Günther; Buecker, Arno

    2014-01-01

    Magnetic resonance imaging (MRI) performed at ultra-high field strengths beyond 3 Tesla (T) has become increasingly prevalent in research and preclinical applications. As such, the inevitable clinical implementation of such systems lies on the horizon. The major benefit of ultra-high field MRI is the markedly increased signal-to-noise ratios achievable, enabling acquisition of MR images with simultaneously greater spatial and temporal resolution. However, at field strengths higher than 3 T, the efficacy of Gd(III)-based contrast agents is diminished due to decreased r1 relaxivity, somewhat limiting imaging of the vasculature and contrast-enhanced imaging of tumors. There have been extensive efforts to design new contrast agents with high r1 relaxivities based on macromolecular compounds or nanoparticles; however, the efficacy of these agents at ultra-high field strengths has not yet been proven. The aim of this review article is to provide an overview of the basic principles of MR contrast enhancement processes and to highlight the main factors influencing relaxivity. In addition, challenges and opportunities for contrast-enhanced MRI at ultra-high field strengths will be explored. Various approaches for the development of effective contrast agent molecules that are suitable for a broad spectrum of applied field strengths will be discussed in the context of the current literature.

  8. In vivo high field magnetic resonance imaging and spectroscopy of adult zebrafish

    NARCIS (Netherlands)

    Kabli, Samira

    2009-01-01

    This thesis contains the results of imaging of adult zebrafish by using different MR approaches. We present the first high resolution mMR images of adult zebrafish. To achieve high spatial resolution we used a magnetic field of 9.4T, in combination with strong magnetic field gradients (1000 mT/m) an

  9. High-field studies of quantum oscillations in quasi-two-dimensional organic metals

    Science.gov (United States)

    Sandhu, Pravindrajit

    The organic metals derived from the molecule BEDT-TTF (or ET for short) are important as model systems for the study of low-dimensional phenomena. These materials are molecular crystals with a low Fermi energy (10--100 meV), high mobility (˜104 cm2/Vs) and highly anisotropic Fermi surfaces. We have conducted experimental studies of ( i) the Shubnikov-de Haas (SdH) effect in pulsed fields up to 50 T and (ii) the de Haas-van Alphen (dHvA) effect in steady fields up to 33 T on alpha - (ET)2 MHg(SCN) 4 (where M = K, Tl and NH4) and kappa - (ET)2 Cu (NCS)2. At these high fields, the wave shape as well as the temperature and field-dependence of the oscillations deviate from the behavior predicted by the standard Lifshitz-Kosevich theory. These measurements reveal the limits of the conventional theory of metals and lay the ground-work for extending the theory to low-dimensional systems. We have also performed extended Huckel tight-binding calculations to model the effects of pressure and uniaxial stress on the electronic band structure of kappa - (ET)2 KHg (SCN)4 and kappa - (ET)2 Cu (NCS)2. The calculated changes in the Fermi surface topology are in excellent agreement with the experimental values determined from SdH measurements. We also report predictions of the effects of uniaxial stress in the transverse directions and discuss the behavior of the effective mass and magnetic breakdown probability. Finally, we have investigated the origin of anomalous magnetic breakdown frequencies in the dHvA effect that are forbidden according to semi-classical theories. We construct a tight-binding model based on the realistic band-structure of the system, which is then solved numerically to compute the field-dependence of the magnetization. This model provides a natural description for the phenomenon of magnetic breakdown between co-existing closed and open Fermi surfaces and accounts for the anomalous frequencies that are observed experimentally. The occurrence of these

  10. Research and Development of Wires and Cables for High-Field Accelerator Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Barzi, Emanuela; Zlobin, Alexander V.

    2016-04-01

    The latest strategic plans for High Energy Physics endorse steadfast superconducting magnet technology R&D for future Energy Frontier Facilities. This includes 10 to 16 T Nb3Sn accelerator magnets for the luminosity upgrades of the Large Hadron Collider and eventually for a future 100 TeV scale proton-proton (pp) collider. This paper describes the multi-decade R&D investment in the Nb3Sn superconductor technology, which was crucial to produce the first reproducible 10 to 12 T accelerator-quality dipoles and quadrupoles, as well as their scale-up. We also indicate prospective research areas in superconducting Nb3Sn wires and cables to achieve the next goals for superconducting accelerator magnets. Emphasis is on increasing performance and decreasing costs while pushing the Nb3Sn technology to its limits for future pp colliders.

  11. Invited Article: Development of high-field superconducting Ioffe magnetic traps

    Science.gov (United States)

    Yang, L.; Brome, C. R.; Butterworth, J. S.; Dzhosyuk, S. N.; Mattoni, C. E. H.; McKinsey, D. N.; Michniak, R. A.; Doyle, J. M.; Golub, R.; Korobkina, E.; O'Shaughnessy, C. M.; Palmquist, G. R.; Seo, P.-N.; Huffman, P. R.; Coakley, K. J.; Mumm, H. P.; Thompson, A. K.; Yang, G. L.; Lamoreaux, S. K.

    2008-03-01

    We describe the design, construction, and performance of three generations of superconducting Ioffe magnetic traps. The first two are low current traps, built from four racetrack shaped quadrupole coils and two solenoid assemblies. Coils are wet wound with multifilament NbTi superconducting wires embedded in epoxy matrices. The magnet bore diameters are 51 and 105mm with identical trap depths of 1.0T at their operating currents and at 4.2K. A third trap uses a high current accelerator-type quadrupole magnet and two low current solenoids. This trap has a bore diameter of 140mm and tested trap depth of 2.8T. Both low current traps show signs of excessive training. The high current hybrid trap, on the other hand, exhibits good training behavior and is amenable to quench protection.

  12. Research and Development of Nb3Sn Wires and Cables for High-Field Accelerator Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Barzi, Emanuela [Fermilab; Zlobin, Alexander V. [Fermilab

    2016-02-18

    The latest strategic plans for High Energy Physics endorse steadfast superconducting magnet technology R&D for future Energy Frontier Facilities. This includes 10 to 16 T Nb3Sn accelerator magnets for the luminosity upgrades of the Large Hadron Collider and eventually for a future 100 TeV scale proton-proton (pp) collider. This paper describes the multi-decade R&D investment in the Nb3Sn superconductor technology, which was crucial to produce the first reproducible 10 to 12 T accelerator-quality dipoles and quadrupoles, as well as their scale-up. We also indicate prospective research areas in superconducting Nb3Sn wires and cables to achieve the next goals for superconducting accelerator magnets. Emphasis is on increasing performance and decreasing costs while pushing the Nb3Sn technology to its limits for future pp colliders.

  13. AC loss evaluation of an HTS insert for high field magnet cooled by cryocoolers

    Science.gov (United States)

    Kajikawa, Kazuhiro; Awaji, Satoshi; Watanabe, Kazuo

    2016-12-01

    AC losses in a high temperature superconducting (HTS) insert coil for 25-T cryogen-free superconducting magnet during its initial energization are numerically calculated under the assumption of slab approximation. The HTS insert consisting of 68 single pancakes wound using coated conductors generates a central magnetic field of 11.5 T in addition to the contribution of 14.0 T from a set of low temperature superconducting (LTS) outsert coils. Both the HTS insert and the LTS coils are cooled using cryocoolers, and energized simultaneously up to the central field of 25.5 T with a constant ramp rate for 60 min. The influences of the magnitudes and orientations of locally applied magnetic fields, magnetic interactions between turns and transport currents flowing in the windings are taken into account in the calculations of AC losses. The locally applied fields are separated into axial and radial components, and the individual contributions of these field components to the AC losses are simply summed up to obtain the total losses. The AC losses due to the axial fields become major in the beginning of energization, whereas the total losses monotonically increase with time after the AC losses due to the radial fields become major.

  14. Survey of Processing Methods for High Strength High Conductivity Wires for High Field Magnet Applications

    Energy Technology Data Exchange (ETDEWEB)

    Han, K.; Embury, J.D.

    1998-10-01

    This paper will deal with the basic concepts of attaining combination of high strength and high conductivity in pure materials, in-situ composites and macrocomposites. It will survey current attainments, and outline where some future developments may lie in developing wire products that are close to the theoretical strength of future magnet applications.

  15. Application of Nb3Sn superconductors in high-field accelerator magnets

    NARCIS (Netherlands)

    Ouden, den Andries; Wessel, Sander; Krooshoop, Erik; Kate, ten Herman

    1997-01-01

    Last year a record central field of 11 T at first excitation at 4.4 K has been achieved with the experimental LHC model dipole magnet MSUT by utilising a high Jc powder-in-tube Nb3Sn conductor. This is the first real breakthrough towards fields well above 10 T at 4 K. The clear influence of magnetis

  16. Yang-Lee edge singularities determined from experimental high-field magnetization data

    Energy Technology Data Exchange (ETDEWEB)

    Binek, Ch.; Kleemann, W. [Laboratorium fuer Angewandte Physik, Gerhard-Mercator-Universitaet Duisburg, Duisburg (Germany); Aruga Katori, H. [RIKEN, Institute of Physical and Chemical Research, Wako, Saitama (Japan)

    2001-09-03

    The isothermal magnetization m(H) of the metamagnet FeCl{sub 2} is measured in axial magnetic fields 0{<=}{mu}{sub 0}H{sub a}{<=}12 T at temperatures 34{<=}T{<=}53 K above the Neel temperature, where the system is essentially a two-dimensional Ising ferromagnet. The analysis of the data indicates experimental accessibility of the critical exponent {mu} of the Yang-Lee edge singularities. They manifest themselves in divergences of the density functions g({theta}), which quantify the distribution of the zeros of the partition function on the Lee-Yang unit circle in the complex plane. In accordance with the hypothesis of universality, a critical exponent close to the theoretical prediction for the two-dimensional Ising ferromagnet, {mu}=-1/6, is found. (author). Letter-to-the-editor.

  17. High-field (9.4 T) ~1H magnetic resonance microscopy of mouse brain

    Institute of Scientific and Technical Information of China (English)

    丁广良; 胡红兵; 李丽云; 叶朝辉

    1997-01-01

    The FLASH and STEAM pulse sequences were used to perform the microimaging and localized spectroscopy of brain of living and dead mice, respectively. The phase-shift presaturation approach was used to sup-press water NMR signal. The experimental results show that the differences in localized spectra and MR images of brain between live and dead mice can be observed by means of magnetic resonance microscopy.

  18. NMR in pulsed high-field magnets and application to high-T(C) superconductors.

    Science.gov (United States)

    Stork, H; Bontemps, P; Rikken, G L J A

    2013-09-01

    This article deals with the implementation of Nuclear Magnetic Resonance (NMR) experiments in pulsed magnetic fields at the pulsed-field facility of the Laboratoire National des Champs Magnétiques Intenses and its application to the high-T(C) superconductor YBa2Cu3O6.51. The experimental setup is described in detail, including a low-temperature probe head adapted for pulsed fields. An entire paragraph is dedicated to the discussion of NMR in pulsed field and the introduction of an advanced deconvolution technique making use of the induction voltage in an additional pick-up coil. The (63)Cu/(65)Cu NMR experiments on an YBa2Cu3O6.51 single crystal were performed at 2.5K during a field pulse of 46.8-T-amplitude. In the recorded spectrum the (63)Cu center line and high-frequency satellites as well as the (65)Cu center line are identified and are compared with results in literature.

  19. [Comparative assessment of MR-semiotics of acutest intracerebral hematomas in low- and extra high-field frequency magnetic resonance tomography].

    Science.gov (United States)

    Skvortsova, V I; Burenchev, D V; Tvorogova, T V; Guseva, O I; Prokhorov, A V; Smirnov, A M; Kupriianov, D A; Pirogov, Iu A

    2009-01-01

    An objective of the study was to compare sensitivity of low- and extra high-field frequency magnetic resonance (MR) tomography of acutest intracerebral hematomas (ICH) and to assess differences between symptoms in obtained images. A study was conducted using experimental ICH in rats (n=6). Hematomas were formed by two injections of autologic blood into the brain. MR-devices "Bio Spec 70/30" with magnetic field strength of 7 T and "Ellipse-150" with magnetic field strength of 0,15 T were used in the study. MR-tomography was carried out 3-5 h after the injections. Both MR-devices revealed the presence of pathological lesion in all animals. Extra highfield frequency MR-tomography showed the specific signs of ICH caused by the paramagnetic effect of deoxyhemoglobin in T2 and T2*-weighted images (WI) and low frequency MR-tomography - in T2*-WI only. The comparable sensitivity of low- and extra high-field frequency MR-devices in acutest ICH was established.

  20. Tailored RF pulse optimization for magnetization inversion at ultra high field

    CERN Document Server

    Hurley, Aaron C; Li, Bai; Aickelin, Uwe; Coxon, Ron; Glover, Paul; Gowland, Penny A

    2010-01-01

    The radiofrequency (RF) transmit field is severely inhomogeneous at ultrahigh field due to both RF penetration and RF coil design issues. This particularly impairs image quality for sequences that use inversion pulses such as magnetization prepared rapid acquisition gradient echo and limits the use of quantitative arterial spin labeling sequences such as flow-attenuated inversion recovery. Here we have used a search algorithm to produce inversion pulses tailored to take into account the heterogeneity of the RF transmit field at 7 T. This created a slice selective inversion pulse that worked well (good slice profile and uniform inversion) over the range of RF amplitudes typically obtained in the head at 7 T while still maintaining an experimentally achievable pulse length and pulse amplitude in the brain at 7 T. The pulses used were based on the frequency offset correction inversion technique, as well as time dilation of functions, but the RF amplitude, frequency sweep, and gradient functions were all generate...

  1. Characterization of a dielectric phantom for high-field magnetic resonance imaging applications

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Qi, E-mail: Qi.Duan@nih.gov; Duyn, Jeff H.; Gudino, Natalia; Zwart, Jacco A. de; Gelderen, Peter van [Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland 20892 (United States); Sodickson, Daniel K.; Brown, Ryan [The Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York 10016 (United States)

    2014-10-15

    Purpose: In this work, a generic recipe for an inexpensive and nontoxic phantom was developed within a range of biologically relevant dielectric properties from 150 MHz to 4.5 GHz. Methods: The recipe includes deionized water as the solvent, NaCl to primarily control conductivity, sucrose to primarily control permittivity, agar–agar to gel the solution and reduce heat diffusivity, and benzoic acid to preserve the gel. Two hundred and seventeen samples were prepared to cover the feasible range of NaCl and sucrose concentrations. Their dielectric properties were measured using a commercial dielectric probe and were fitted to a 3D polynomial to generate a recipe describing the properties as a function of NaCl concentration, sucrose concentration, and frequency. Results: Results indicated that the intuitive linear and independent relationships between NaCl and conductivity and between sucrose and permittivity are not valid. A generic polynomial recipe was developed to characterize the complex relationship between the solutes and the resulting dielectric values and has been made publicly available as a web application. In representative mixtures developed to mimic brain and muscle tissue, less than 2% difference was observed between the predicted and measured conductivity and permittivity values. Conclusions: It is expected that the recipe will be useful for generating dielectric phantoms for general magnetic resonance imaging (MRI) coil development at high magnetic field strength, including coil safety evaluation as well as pulse sequence evaluation (including B{sub 1}{sup +} mapping, B{sub 1}{sup +} shimming, and selective excitation pulse design), and other non-MRI applications which require biologically equivalent dielectric properties.

  2. Comparison of High-field and Low-field Magnetic Resonance Imaging of Stifle Joint Disorders in Dogs.

    Science.gov (United States)

    Przeworski, A; Adamiak, Z; Głodek, J

    2016-09-01

    The most common cause of hindlimb lameness in dogs is cranial cruciate ligament rupture. In 48-77.3% of the population this trauma leads to secondary damage of the meniscus. Depending on the magnetic strength of the used device, different diagnostic accuracy can be achieved. The examination sensitivity of magnetic resonance imaging is affected by many factors which are independent of diagnostic strength, such as correct positioning of the patient, size of the stifle joint examined, or selection of the right protocol of sequences. Sensitivity of meniscus damage detection was 100% and 90%, respectively, in high- and low-field magnetic resonance. The best results were reported during examination of the stifle in dogs above 10 kg b.w. at a flexion angle of 145°, and in sagittal and dorsal planes. Regardless of the magnetic strength applied, imaging of the whole cranial cruciate ligament is difficult. Moreover, MRI allows the detection of the first signs of osteoarthritis, which were observed 4 and 6 weeks after rupture of the cranial cruciate ligament using high and low-field MRI. This also applies to lesions in the subchondral bone or a bone marrow which occurred in association with insufficiency of the stifle joint, and were mainly localized in the epiphysis of the femur and tibia. The present article provides a comparison of different examination protocols and images of damaged stifle structures, such as menisci, ligaments and bones of the stifle joint visualized with low-field and high-field magnetic resonance. Magnetic resonance arthrography is also discussed.

  3. High-resolution T2-weighted cervical cancer imaging : a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna

    NARCIS (Netherlands)

    Hoogendam, Jaap; van Kalleveen, Irene; Arteaga de Castro, Catalina; Raaijmakers, AJE; Verheijen, René H M; van Den Bosch, Maurice A A J; Klomp, DWJ; Zweemer, RP; Veldhuis, Wouter B.

    2017-01-01

    Objectives: We studied the feasibility of high-resolution T2-weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. Methods: A feasibility study on 20 stage IB1–IIB cervical cancer patients was conducted.

  4. High-resolution T2-weighted cervical cancer imaging : a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna

    NARCIS (Netherlands)

    Hoogendam, Jaap; van Kalleveen, Irene; Arteaga de Castro, Catalina|info:eu-repo/dai/nl/341020648; Raaijmakers, AJE|info:eu-repo/dai/nl/304819662; Verheijen, René H M|info:eu-repo/dai/nl/071420487; van Den Bosch, Maurice A A J|info:eu-repo/dai/nl/182981630; Klomp, DWJ|info:eu-repo/dai/nl/298206382; Zweemer, RP|info:eu-repo/dai/nl/217201687; Veldhuis, Wouter B.|info:eu-repo/dai/nl/249572915

    2017-01-01

    Objectives: We studied the feasibility of high-resolution T2-weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. Methods: A feasibility study on 20 stage IB1–IIB cervical cancer patients was conducted.

  5. Manufacture and Testing of a High Field Gradient Magnetic Fractionation System for Quantitative Detection of Plasmodium falciparum Gametocytes

    Science.gov (United States)

    Karl, Stephan; Woodward, Robert C.; Davis, Timothy M. E.; St. Pierre, Tim G.

    2010-12-01

    Plasmodium falciparum is the most dangerous of the human malaria parasite species and accounts for millions of clinical episodes of malaria each year in tropical countries. The pathogenicity of Plasmodium falciparum is a result of its ability to infect erythrocytes where it multiplies asexually over 48 h or develops into sexual forms known as gametocytes. If sufficient male and female gametocytes are taken up by a mosquito vector, it becomes infectious. Therefore, the presence and density of gametocytes in human blood is an important indicator of human-to-mosquito transmission of malaria. Recently, we have shown that high field gradient magnetic fractionation improves gametocyte detection in human blood samples. Here we present two important new developments. Firstly we introduce a quantitative approach to replace the previous qualitative method and, secondly, we describe a novel method that enables cost-effective production of the magnetic fractionation equipment required to carry out gametocyte quantification. We show that our custom-made magnetic fractionation equipment can deliver results with similar sensitivity and convenience but for a small fraction of the cost.

  6. Windows on the Human Body – in Vivo High-Field Magnetic Resonance Research and Applications in Medicine and Psychology

    Directory of Open Access Journals (Sweden)

    Ewald Moser

    2010-06-01

    Full Text Available Analogous to the evolution of biological sensor-systems, the progress in “medical sensor-systems”, i.e., diagnostic procedures, is paradigmatically described. Outstanding highlights of this progress are magnetic resonance imaging (MRI and spectroscopy (MRS, which enable non-invasive, in vivo acquisition of morphological, functional, and metabolic information from the human body with unsurpassed quality. Recent achievements in high and ultra-high field MR (at 3 and 7 Tesla are described, and representative research applications in Medicine and Psychology in Austria are discussed. Finally, an overview of current and prospective research in multi-modal imaging, potential clinical applications, as well as current limitations and challenges is given.

  7. Windows on the Human Body – in Vivo High-Field Magnetic Resonance Research and Applications in Medicine and Psychology

    Science.gov (United States)

    Moser, Ewald; Meyerspeer, Martin; Fischmeister, Florian Ph. S.; Grabner, Günther; Bauer, Herbert; Trattnig, Siegfried

    2010-01-01

    Analogous to the evolution of biological sensor-systems, the progress in “medical sensor-systems”, i.e., diagnostic procedures, is paradigmatically described. Outstanding highlights of this progress are magnetic resonance imaging (MRI) and spectroscopy (MRS), which enable non-invasive, in vivo acquisition of morphological, functional, and metabolic information from the human body with unsurpassed quality. Recent achievements in high and ultra-high field MR (at 3 and 7 Tesla) are described, and representative research applications in Medicine and Psychology in Austria are discussed. Finally, an overview of current and prospective research in multi-modal imaging, potential clinical applications, as well as current limitations and challenges is given. PMID:22219684

  8. The high-field magnet endstation for X-ray magnetic dichroism experiments at ESRF soft X-ray beamline ID32

    Science.gov (United States)

    Kummer, K.; Fondacaro, A.; Jimenez, E.; Velez-Fort, E.; Amorese, A.; Aspbury, M.; Yakhou-Harris, F.; van der Linden, P.; Brookes, N. B.

    2016-01-01

    A new high-field magnet endstation for X-ray magnetic dichroism experiments has been installed and commissioned at the ESRF soft X-ray beamline ID32. The magnet consists of two split-pairs of superconducting coils which can generate up to 9 T along the beam and up to 4 T orthogonal to the beam. It is connected to a cluster of ultra-high-vacuum chambers that offer a comprehensive set of surface preparation and characterization techniques. The endstation and the beam properties have been designed to provide optimum experimental conditions for X-ray magnetic linear and circular dichroism experiments in the soft X-ray range between 400 and 1600 eV photon energy. User operation started in November 2014. PMID:26917134

  9. Ultra high field magnetic resonance imaging; L'imagerie par resonance magnetique a ultra-haut champ. L'aimant, piece maitresse de l'imageur. Memo C: les principales techniques d'imagerie medicale

    Energy Technology Data Exchange (ETDEWEB)

    Lethimonnier, F. [CEA Saclay, Institut d' Imagerie Biomedicale - NeuroSpin, Dir. des Sciences du Vivant, 91 - Gif-sur-Yvette (France); Vedrine, P. [CEA Saclay, Direction des Sciences de la Matiere, 91 - Gif-sur-Yvette (France)

    2008-07-01

    Understanding human brain function, brain development and brain dysfunction is one of the great challenges of the twenty first century. Biomedical imaging has now run up against a number of technical constraints that are exposing limits to its potential. In order to overcome the current limits to high-field magnetic resonance cerebral imaging (MRI) and unleash its fullest potential, the Cea has built NeuroSpin, an ultra-high-field neuroimaging facility at its Saclay centre (in the Essonne). NeuroSpin already boasts three fully operational MRI systems. The first is a 3-tesla high-field system and the second is a very-high-field 7-tesla system, both of which are dedicated to clinical studies and investigations in humans, while the third is an ultra-high-field 17.65-tesla system designed for studies on small animals. In 2011, NeuroSpin will be commissioning an 11.7-tesla ultra-high-field system of unprecedented power that is designed for research on human subjects. The level of the magnetic field and the scale required will make this joint French-German project to build the magnet a breakthrough in the international arena. (authors)

  10. Preoperative 3T high field blood oxygen level dependent functional magnetic resonance imaging for glioma involving sensory cortical areas

    Institute of Scientific and Technical Information of China (English)

    LI Shao-wu; WANG Jiang-fei; JIANG Tao; LI Shou-wei; ZHANG Wen-bo; LI Zi-xiao; ZHANG Zhong; DAI Jian-ping; WANG Zhong-cheng

    2010-01-01

    Background Localization of sensory cortical areas during the operation is essential to preserve the sensory function.Intraoperative direct electrostimulation under awake anesthesia is the golden standard but time-consuming. We applied 3T high field blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) to identify the relationship between glioma and cortical sensory areas preoperatively and to guide intraoperative direct electrostimulation for quick and precise localization.Methods Five glioma patients with sensory cortex involvement by or next to the lesion had preoperative BOLD fMRI to determine the spatial relationship of cortical sensory areas to the tumours. Bilateral hand opposite movement was performed by these patients for fMRI. Precentral and postcentral gyri were identified by electrical stimulation during the operation. Karnofsky Performance Status scores of the patients' pre- and postoperative and the role of BOLD fMRI were evaluated.Results The cortical sensory areas were all activated in five glioma patients involving postcentral gyrus areas by BOLDf MRI with bilateral hand opposite movement. The detected activation areas corresponded with the results from cortical electrical stimulation.Conclusions The relationship between cortical sensory areas and tumour can be accurately shown by BOLD fMRI before operation. And the information used to make the tumour resection could obtain good clinical results.

  11. Lung disease assessment in primary ciliary dyskinesia: a comparison between chest high-field magnetic resonance imaging and high-resolution computed tomography findings

    Directory of Open Access Journals (Sweden)

    Iacotucci Paola

    2009-08-01

    Full Text Available Abstract Background Primary ciliary dyskinesia (PCD is associated with pulmonary involvement that requires periodical assessment. Chest high-resolution computed tomography (HRCT has become the method of choice to evaluate chronic lung disease, but entails exposure to ionizing radiation. Magnetic resonance imaging (MRI has been proposed as a potential radiation-free technique in several chest disorders. Aim of our study is to evaluate whether high-field MRI is as effective as HRCT in identifying PCD pulmonary abnormalities. We also analyzed the relationships between the severity and extension of lung disease, and functional data. Methods Thirteen PCD patients (8 children/5 adults; median age, 15.2 yrs underwent chest HRCT and high-field 3T MRI, spirometry, and deep throat or sputum culture. Images were scored using a modified version of the Helbich system. Results HRCT and MRI total scores were 12 (range, 6–20 and 12 (range, 5–17, respectively. Agreement between HRCT and MRI scores was good or excellent (r > 0.8. HRCT and MRI total scores were significantly related to forced vital capacity (r = -0.5, p = 0.05; and r = -0.7, p = 0.009, respectively and forced expiratory volume at 1 second (r = -0.6, p = 0.03; and r = -0.7, p = 0.009, respectively. Conclusion Chest high-field 3T MRI appears to be as effective as HRCT in assessing the extent and severity of lung abnormalities in PCD. MRI scores might be used for longitudinal assessment and be an outcome surrogate in future studies.

  12. High-field magnetization of heusler alloys Fe2 XY ( X = Ti, V, Cr, Mn, Fe, Co, Ni; Y = Al, Si)

    Science.gov (United States)

    Kourov, N. I.; Marchenkov, V. V.; Korolev, A. V.; Belozerova, K. A.; Weber, H. W.

    2015-10-01

    The magnetization curves of ferromagnetic Heusler alloys Fe2 XY (where X = Ti, V, Cr, Mn, Fe, Co, Ni are transition 3 d elements and Y = Al, Si are the s and p elements of the third period of the Periodic Table) have been measured at T = 4.2 K in the field range H ≤ 70 kOe. It has been shown that the high-field ( H ≥ 20 kOe) magnetization is described within the Stoner model.

  13. Metal-Metal Interactions in Trinuclear Copper(II) Complexes [Cu3(RCOO)4(H2TEA)2] and Binuclear [Cu2(RCOO)2(H2TEA)2]. Syntheses and Combined Structural, Magnetic, High-Field Electron Paramagnetic Resonance, and Theoretical Studies.

    Science.gov (United States)

    Ozarowski, Andrew; Calzado, Carmen J; Sharma, Raj Pal; Kumar, Santosh; Jezierska, Julia; Angeli, Celestino; Spizzo, Federico; Ferretti, Valeria

    2015-12-21

    The trinuclear [Cu3(RCOO)4(H2TEA)2] copper(II) complexes, where RCOO(-) = 2-furoate (1), 2-methoxybenzoate (2), and 3-methoxybenzoate (3, 4), as well as dimeric species [Cu2(H2TEA)2(RCOO)2]·2H2O, have been prepared by adding triethanolamine (H3TEA) at ambient conditions to hydrated Cu(RCOO)2 salts. The newly synthesized complexes have been characterized by elemental analyses, spectroscopic techniques (IR and UV-visible), magnetic susceptibility, single crystal X-ray structure determination and theoretical calculations, using a Difference Dedicated Configuration Interaction approach for the evaluation of magnetic coupling constants. In 1 and 2, the central copper atom lies on an inversion center, while in the polymorphs 3 and 4, the three metal centers are crystallographically independent. The zero-field splitting parameters of the trimeric compounds, D and E, were derived from high-field, high-frequency electron paramagnetic resonance spectra at temperatures ranging from 3 to 290 K and were used for the interpretation of the magnetic data. It was found that the dominant interaction between the terminal and central Cu sites J12 is ferromagnetic in nature in all complexes, even though differences have been found between the symmetrical or quasi-symmetrical complexes 1-3 and non-symmetrical complex 4, while the interaction between the terminal centers, J23, is negligible.

  14. PEGylated NaHoF4 nanoparticles as contrast agents for both X-ray computed tomography and ultra-high field magnetic resonance imaging.

    Science.gov (United States)

    Ni, Dalong; Zhang, Jiawen; Bu, Wenbo; Zhang, Chen; Yao, Zhenwei; Xing, Huaiyong; Wang, Jing; Duan, Fei; Liu, Yanyan; Fan, Wenpei; Feng, Xiaoyuan; Shi, Jianlin

    2016-01-01

    It is well-known that multimodal imaging can integrate the advantages of different imaging modalities by overcoming their individual limitations. As ultra-high field magnetic resonance imaging (MRI) will be inevitably used in future MRI/X-ray computed tomography (CT) scanner, it is highly expected to develop high-performance nano-contrast agents for ultra-high field MR and CT dual-modality imaging, which has not been reported yet. Moreover, specific behavior of nano-contrast agents for ultra-high field MRI is a challenging work and still remains unknown. Herein, a novel type of NaHoF4 nanoparticles (NPs) with varied particle sizes were synthesized and explored as high-performance dual-modality contrast agents for ultra-high field MR and CT imaging. The specific X-ray absorption and MR relaxivity enhancements with varied nanoparticle diameters (3 nm, 7 nm, 13 nm and 29 nm) under different magnetic field (1.5/3.0/7.0 T) are investigated. Based on experimental results and theoretical analysis, the Curie and dipolar relaxation mechanisms of NaHoF4 NPs are firstly separated. Our results will greatly promote the future medical translational development of the NaHoF4 nano-contrast agents for ultra-high field MR/CT dual-modality imaging applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Determination of the intersublattice exchange interactions in GdCo12-xFexB6 (x = 0-3) intermetallic compounds by high field magnetization measurements

    Science.gov (United States)

    Diop, L. V. B.; Isnard, O.; Skourski, Y.; Ballon, G.

    2013-05-01

    High field magnetization measurements up to 60 T on free powder samples from GdCo12-xFexB6 (x = 0-3) compounds are reported. The data were used to evaluate the microscopic exchange interaction integral, JGd-3d, between Gd and 3d (Co,Fe) spins. The systems are ferrimagnets; they order magnetically between TC = 95 K for x = 3 and TC = 165 K for x = 0. The low temperature magnetization curves as well as the temperature dependence of intrinsic magnetic parameters are determined by magnetic measurements in pulsed magnetic field. The average magnetic moment ⟨μCo+Fe⟩ per mean transition metal atom (Co + Fe) is small and increases with increasing Fe concentration from 0.44 μΒ for x = 0 to 0.51 μΒ for x = 3 at T = 4 K. From high field magnetization curves, a value of JGd-3d/kB = -4.65 K is derived for x = 0, whereas mean field approximation yields a much larger 3d-3d exchange integral of JCo-Co/kB = 105 K. The obtained results reveal an increase of -JGd-3d/kB with Fe concentration. For x = 0.5, the intersublattice coefficient nGd-3d is found to keep an almost constant value of 5.87 ± 0.13 T*f.u.*μB-1 whatever the temperature in the 2 to 60 K range.

  16. Preliminary Observations on Sensitivity and Specificity of Magnetization Transfer Asymmetry for Imaging Myelin of Rat Brain at High Field.

    Science.gov (United States)

    Kim, Jae-Woong; Choi, Jiye; Cho, Janggeun; Lee, Chulhyun; Jeon, Daejong; Park, Sung-Hong

    2015-01-01

    Magnetization transfer ratio (MTR) has been often used for imaging myelination. Despite its high sensitivity, the specificity of MTR to myelination is not high because tissues with no myelin such as muscle can also show high MTR. In this study, we propose a new magnetization transfer (MT) indicator, MT asymmetry (MTA), as a new method of myelin imaging. The experiments were performed on rat brain at 9.4 T. MTA revealed high signals in white matter and significantly low signals in gray matter and muscle, indicating that MTA has higher specificity than MTR. Demyelination and remyelination studies demonstrated that the sensitivity of MTA to myelination was as high as that of MTR. These experimental results indicate that MTA can be a good biomarker for imaging myelination. In addition, MTA images can be efficiently acquired with an interslice MTA method, which may accelerate clinical application of myelin imaging.

  17. YbNi{sub 4}P{sub 2}. Single crystal growth by the Czochralski method and high-field magnetization measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kliemt, Kristin; Krellner, Cornelius [Goethe-University, Frankfurt (Germany); Foerster, Tobias [HLD, Helmholtz-Zentrum Dresden-Rossendorf, Dresden (Germany); Brando, Manuel [MPI for Chemical Physics of Solids, Dresden (Germany)

    2016-07-01

    We have investigated a new generation of YbNi{sub 4}P{sub 2} single crystals that were grown from a levitating melt by the Czochralski method. With T{sub C}= 0.17 K, this ferromagnetic material has the lowest Curie temperature ever observed among stoichiometric compounds. A quantum critical point occurs in the substitution series YbNi{sub 4}(P{sub 1-x}As{sub x}){sub 2} at x ∼ 0.1. The hybridization between localized f-electrons and the conduction electrons leads to a Fermi-liquid ground state with narrow bands and strongly enhanced effective electronic masses (heavy fermion system, Kondo temperature 8 K). An external magnetic field can split the bands, deform the Fermi surface and simultaneously suppress the Kondo interaction. If such a deformation changes the topology, it is called a Lifshitz transition. Previous thermodynamic and electrical transport studies have found indications for Lifshitz transitions in this Kondo lattice system. We report on results of high-field magnetization measurements at low temperature to further investigate the putative Lifshitz transitions in YbNi{sub 4}P{sub 2}.

  18. ARC: A compact, high-field, fusion nuclear science facility and demonstration power plant with demountable magnets

    Energy Technology Data Exchange (ETDEWEB)

    Sorbom, B.N., E-mail: bsorbom@mit.edu; Ball, J.; Palmer, T.R.; Mangiarotti, F.J.; Sierchio, J.M.; Bonoli, P.; Kasten, C.; Sutherland, D.A.; Barnard, H.S.; Haakonsen, C.B.; Goh, J.; Sung, C.; Whyte, D.G.

    2015-11-15

    Highlights: • ARC reactor designed to have 500 MW fusion power at 3.3 m major radius. • Compact, simplified design allowed by high magnetic fields and jointed magnets. • ARC has innovative plasma physics solutions such as inboardside RF launch. • High temperature superconductors allow high magnetic fields and jointed magnets. • Liquid immersion blanket and jointed magnets greatly simplify tokamak reactor design. - Abstract: The affordable, robust, compact (ARC) reactor is the product of a conceptual design study aimed at reducing the size, cost, and complexity of a combined fusion nuclear science facility (FNSF) and demonstration fusion Pilot power plant. ARC is a ∼200–250 MWe tokamak reactor with a major radius of 3.3 m, a minor radius of 1.1 m, and an on-axis magnetic field of 9.2 T. ARC has rare earth barium copper oxide (REBCO) superconducting toroidal field coils, which have joints to enable disassembly. This allows the vacuum vessel to be replaced quickly, mitigating first wall survivability concerns, and permits a single device to test many vacuum vessel designs and divertor materials. The design point has a plasma fusion gain of Q{sub p} ≈ 13.6, yet is fully non-inductive, with a modest bootstrap fraction of only ∼63%. Thus ARC offers a high power gain with relatively large external control of the current profile. This highly attractive combination is enabled by the ∼23 T peak field on coil achievable with newly available REBCO superconductor technology. External current drive is provided by two innovative inboard RF launchers using 25 MW of lower hybrid and 13.6 MW of ion cyclotron fast wave power. The resulting efficient current drive provides a robust, steady state core plasma far from disruptive limits. ARC uses an all-liquid blanket, consisting of low pressure, slowly flowing fluorine lithium beryllium (FLiBe) molten salt. The liquid blanket is low-risk technology and provides effective neutron moderation and shielding, excellent

  19. Short-lived charge-transfer excitons in organic photovoltaic cells studied by high-field magneto-photocurrent.

    Science.gov (United States)

    Devir-Wolfman, Ayeleth H; Khachatryan, Bagrat; Gautam, Bhoj R; Tzabary, Lior; Keren, Amit; Tessler, Nir; Vardeny, Z Valy; Ehrenfreund, Eitan

    2014-07-29

    The main route of charge photogeneration in efficient organic photovoltaic cells based on bulk hetero-junction donor-acceptor blends involves short-lived charge-transfer excitons at the donor-acceptor interfaces. The cell efficiency is critically affected by the charge-transfer exciton recombination and dissociation processes. By measuring the magneto-photocurrent under ambient conditions at room temperature, we show here that magnetic field-induced spin-mixing among the charge-transfer exciton spin sublevels occurs in fields up to at least 8.5 Tesla. The resulting magneto-photocurrent increases at high fields showing non-saturating behaviour up to the highest applied field. We attribute the observed high-field spin-mixing mechanism to the difference in the donor-acceptor g-factors. The non-saturating magneto-photocurrent response at high field indicates that there exist charge-transfer excitons with lifetime in the sub-nanosecond time domain. The non-Lorentzian high-field magneto-photocurrent response indicates a dispersive decay mechanism that originates due to a broad distribution of charge-transfer exciton lifetimes.

  20. High-field magnetic resonance imaging of the developing human brain from the 10th to the 16th week of gestational Age.

    Science.gov (United States)

    Sbarbati, A; Marzola, P; Simonati, A; Nicolato, E; Osculati, F

    1998-01-01

    In the present work, high-field magnetic resonance imaging (HF-MRI) was applied to study the developing human brain paying particular attention to the structures of interest in pathology of malformation. The aim of the work was to evaluate the possible application of HF-MRI to the analysis of brain development in the absence of some limits of conventional histological technique. Seven formalin-fixed human fetuses of 50, 65, 70, 85, 110, 116 and 125 mm crown/ rump length (corresponding to a gestational age ranging from 10 to 16 weeks) were examined in an imager-spectrometer equipped with a 4. 7-tesla horizontal magnet with a 33-cm bore. In the brain of all the fetuses the telencephalic, mesencephalic and rhombencephalic vesicles were recognizable and an easy quantitative evaluation of the brain curvatures in the absence of distortion due to dissection was possible. Comparing fetuses at different gestational ages, the spatial modification of the different vesicles was evident. In fetuses at 16 weeks of gestational age, stratified compartments of the telencephalic wall were evident. The germinal zone and the cortical plate were visible: the germinal layer was identifiable as a hypointensity in the periventricular area. The subplate zone and the intermediate zone emitted a strong intensity signal. Our study demonstrates that HF-MRI can contribute to the study of the complex developmental events in the human brain from the 10th to 16th week of gestational age in a submillimetric scale of resolution. This technique can provide information about the morphology of the encephalic vesicles and their relations with the bone cavity that cannot be obtained with conventional methods and may be a useful adjunct to histological techniques.

  1. High Field In vivo13C Magnetic Resonance Spectroscopy of Brain by Random Radiofrequency Heteronuclear Decoupling and Data Undersampling

    Directory of Open Access Journals (Sweden)

    Ningzhi Li

    2017-06-01

    Full Text Available In vivo13C magnetic resonance spectroscopy (MRS is a unique and effective tool for studying dynamic human brain metabolism and the cycling of neurotransmitters. One of the major technical challenges for in vivo13C-MRS is the high radio frequency (RF power necessary for heteronuclear decoupling. In the common practice of in vivo13C-MRS, alkanyl carbons are detected in the spectra range of 10–65 ppm. The amplitude of decoupling pulses has to be significantly greater than the large one-bond 1H-13C scalar coupling (1JCH = 125–145 Hz. Two main proton decoupling methods have been developed: broadband stochastic decoupling and coherent composite or adiabatic pulse decoupling (e.g., WALTZ; the latter is widely used because of its efficiency and superb performance under inhomogeneous B1 field. Because the RF power required for proton decoupling increases quadratically with field strength, in vivo13C-MRS using coherent decoupling is often limited to low magnetic fields [<=4 Tesla (T] to keep the local and averaged specific absorption rate (SAR under the safety guidelines established by the International Electrotechnical Commission (IEC and the US Food and Drug Administration (FDA. Alternately, carboxylic/amide carbons are coupled to protons via weak long-range 1H-13C scalar couplings, which can be decoupled using low RF power broadband stochastic decoupling. Recently, the carboxylic/amide 13C-MRS technique using low power random RF heteronuclear decoupling was safely applied to human brain studies at 7T. Here, we review the two major decoupling methods and the carboxylic/amide 13C-MRS with low power decoupling strategy. Further decreases in RF power deposition by frequency-domain windowing and time-domain random under-sampling are also discussed. Low RF power decoupling opens the possibility of performing in vivo13C experiments of human brain at very high magnetic fields (such as 11.7T, where signal-to-noise ratio as well as spatial and temporal

  2. Role of high-field intraoperative magnetic resonance imaging on a multi-image fusion-guided stereotactic biopsy of the basal ganglia: A case report.

    Science.gov (United States)

    Sun, Xiang; Chen, Zhijuan; Yang, Shuyuan; Zhang, Jianning; Yue, Shuyuan; Wang, Zengguang; Yang, Weidong

    2015-01-01

    The aim of the present case study was to investigate the advantages of intraoperative magnetic resonance imaging (iMRI) on the real-time guidance and monitoring of a stereotactic biopsy. The study describes a patient with intracranial lesions, which were examined by conventional MRI and diffusion tensor imaging using a 1.5T intraoperative MRI system. The digital and pre-operative positron emission/computed tomography image data were transferred to a BrainLAB planning workstation, and a variety of images were automatically fused. The BrainLAB software was then used to reconstruct the corticospinal tract (CST) and create a three-dimensional display of the anatomical association between the CST and the brain lesions. A Leksell surgical planning workstation was used to identify the ideal target site and a reasonable needle track for the biopsy. The 1.5T iMRI was used to effectively monitor the intracranial condition during the brain biopsy procedure. Post-operatively, the original symptoms of the patient were not aggravated and no further neurological deficits were apparent. The histopathological diagnosis of non-Hodgkin's B-cell lymphoma was made. Using high-field iMRI, the multi-image fusion-guided stereotactic brain biopsy allows for a higher positive rate of biopsy and a lower incidence of complications. The approach of combining multi-image fusion images with the frame-based stereotactic biopsy may be clinically useful for intracranial lesions of deep functional areas.

  3. Ultra-robust high-field magnetization plateau and supersolidity in bond-frustrated MnCr2S4

    Science.gov (United States)

    Tsurkan, Vladimir; Zherlitsyn, Sergei; Prodan, Lilian; Felea, Viorel; Cong, Pham Thanh; Skourski, Yurii; Wang, Zhe; Deisenhofer, Joachim; von Nidda, Hans-Albrecht Krug; Wosnitza, Joahim; Loidl, Alois

    2017-01-01

    Frustrated magnets provide a promising avenue for realizing exotic quantum states of matter, such as spin liquids and spin ice or complex spin molecules. Under an external magnetic field, frustrated magnets can exhibit fractional magnetization plateaus related to definite spin patterns stabilized by field-induced lattice distortions. Magnetization and ultrasound experiments in MnCr2S4 up to 60 T reveal two fascinating features: (i) an extremely robust magnetization plateau with an unusual spin structure and (ii) two intermediate phases, indicating possible realizations of supersolid phases. The magnetization plateau characterizes fully polarized chromium moments, without any contributions from manganese spins. At 40 T, the middle of the plateau, a regime evolves, where sound waves propagate almost without dissipation. The external magnetic field exactly compensates the Cr–Mn exchange field and decouples Mn and Cr sublattices. In analogy to predictions of quantum lattice-gas models, the changes of the spin order of the manganese ions at the phase boundaries of the magnetization plateau are interpreted as transitions to supersolid phases. PMID:28345038

  4. The Travelling-Wave Primate System: A New Solution for Magnetic Resonance Imaging of Macaque Monkeys at 7 Tesla Ultra-High Field.

    Directory of Open Access Journals (Sweden)

    Tim Herrmann

    Full Text Available Neuroimaging of macaques at ultra-high field (UHF is usually conducted by combining a volume coil for transmit (Tx and a phased array coil for receive (Rx tightly enclosing the monkey's head. Good results have been achieved using vertical or horizontal magnets with implanted or near-surface coils. An alternative and less costly approach, the travelling-wave (TW excitation concept, may offer more flexible experimental setups on human whole-body UHF magnetic resonance imaging (MRI systems, which are now more widely available. Goal of the study was developing and validating the TW concept for in vivo primate MRI.The TW Primate System (TWPS uses the radio frequency shield of the gradient system of a human whole-body 7 T MRI system as a waveguide to propagate a circularly polarized B1 field represented by the TE11 mode. This mode is excited by a specifically designed 2-port patch antenna. For receive, a customized neuroimaging monkey head receive-only coil was designed. Field simulation was used for development and evaluation. Signal-to-noise ratio (SNR was compared with data acquired with a conventional monkey volume head coil consisting of a homogeneous transmit coil and a 12-element receive coil.The TWPS offered good image homogeneity in the volume-of-interest Turbo spin echo images exhibited a high contrast, allowing a clear depiction of the cerebral anatomy. As a prerequisite for functional MRI, whole brain ultrafast echo planar images were successfully acquired.The TWPS presents a promising new approach to fMRI of macaques for research groups with access to a horizontal UHF MRI system.

  5. Terahertz cyclotron resonance spectroscopy of an AlGaN/GaN heterostructure using a high-field pulsed magnet and an asynchronous optical sampling technique

    Science.gov (United States)

    Spencer, B. F.; Smith, W. F.; Hibberd, M. T.; Dawson, P.; Beck, M.; Bartels, A.; Guiney, I.; Humphreys, C. J.; Graham, D. M.

    2016-05-01

    The effective mass, sheet carrier concentration, and mobility of electrons within a two-dimensional electron gas in an AlGaN/GaN heterostructure were determined using a laboratory-based terahertz cyclotron resonance spectrometer. The ability to perform terahertz cyclotron resonance spectroscopy with magnetic fields of up to 31 T was enabled by combining a high-field pulsed magnet with a modified asynchronous optical sampling terahertz detection scheme. This scheme allowed around 100 transmitted terahertz waveforms to be recorded over the 14 ms magnetic field pulse duration. The sheet density and mobility were measured to be 8.0 × 1012 cm-2 and 9000 cm2 V-1 s-1 at 77 K. The in-plane electron effective mass at the band edge was determined to be 0.228 ± 0.002m0.

  6. Use of movable high-field-strength intraoperative magnetic resonance imaging with awake craniotomies for resection of gliomas: preliminary experience.

    LENUS (Irish Health Repository)

    Leuthardt, Eric C

    2011-07-01

    Awake craniotomy with electrocortical mapping and intraoperative magnetic resonance imaging (iMRI) are established techniques for maximizing tumor resection and preserving function, but there has been little experience combining these methodologies.

  7. Persistence of singlet fluctuations in the coupled spin tetrahedra system Cu2Te2O5Br2 revealed by high-field magnetization, 79Br NQR, and 125Te NMR

    Science.gov (United States)

    Baek, S.-H.; Choi, K.-Y.; Berger, H.; Büchner, B.; Grafe, H.-J.

    2012-11-01

    We present high-field magnetization and 79Br nuclear quadrupole resonance (NQR) and 125Te nuclear magnetic resonance (NMR) studies in the weakly coupled Cu2+ (S=1/2) tetrahedral system Cu2Te2O5Br2. The field-induced level crossing effects were observed by the magnetization measurements in a long-ranged magnetically ordered state which was confirmed by a strong divergence of the spin-lattice relaxation rate T1-1 at T0=13.5 K. In the paramagnetic state, T1-1 reveals an effective singlet-triplet spin gap much larger than that observed by static bulk measurements. Our results imply that the inter- and the intratetrahedral interactions compete, but at the same time they cooperate strengthening effectively the local intratetrahedral exchange couplings. We discuss that the unusual feature originates from the frustrated intertetrahedral interactions.

  8. ARC: A compact, high-field, fusion nuclear science facility and demonstration power plant with demountable magnets

    CERN Document Server

    Sorbom, B N; Palmer, T R; Mangiarotti, F J; Sierchio, J M; Bonoli, P; Kasten, C; Sutherland, D A; Barnard, H S; Haakonsen, C B; Goh, J; Sung, C; Whyte, D G

    2014-01-01

    The affordable, robust, compact (ARC) reactor conceptual design study aims to reduce the size, cost, and complexity of a combined fusion nuclear science facility (FNSF) and demonstration fusion Pilot power plant. ARC is a 270 MWe tokamak reactor with a major radius of 3.3 m, a minor radius of 1.1 m, and an on-axis magnetic field of 9.2 T. ARC has rare earth barium copper oxide (REBCO) superconducting toroidal field coils, which have joints to enable disassembly. This allows the vacuum vessel to be replaced quickly, mitigating first wall survivability concerns, and permits a single device to test many vacuum vessel designs and divertor materials. The design point has a plasma fusion gain of Q_p~13.6, yet is fully non-inductive, with a modest bootstrap fraction of only ~63%. Thus ARC offers a high power gain with relatively large external control of the current profile. This highly attractive combination is enabled by the ~23 T peak field on coil with newly available REBCO superconductor technology. External cu...

  9. Survey of risks related to static magnetic fields in ultra high field MRI; Bestandsaufnahme zu Risiken durch statische Magnetfelder im Zusammenhang mit der Ultrahochfeld-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, H.E. [Max-Planck-Inst. fuer Kognitions- und Neurowissenschaften, Leipzig (Germany); Cramon, D.Y. von [Max-Planck-Inst. fuer Kognitions- und Neurowissenschaften, Leipzig (Germany); Max-Planck-Inst. fuer Neurologische Forschung, Koeln (Germany)

    2008-04-15

    In magnetic resonance imaging (MRI), substantial improvements with respect to sensitivity are expected due to the development of so-called ultra high field scanners, i.e., whole-body scanners with a magnetic field strength of 7 T or above. Users of this technology need to evaluate this benefit for potential risks since commercially available systems are not certified as a medical device for human use. This review provides a detailed survey of static field bioeffects related to the exposure of subjects being scanned, to occupational exposure, and to exposure of the general public under consideration of current standards and directives. According to present knowledge, it is not expected that exposure of human subjects to static magnetic fields of 7 T implies a specific risk of damage or disease provided that known contraindications are observed. The available database does not permit definition of exact thresholds for harmful effects. However, experience from previous application of ultra high field MRI indicates that transient phenomena, such as vertigo, nausea, metallic taste, or magnetophosphenes, are more frequently observed. In particular, movements in the field or the gradient of the fringe field seem to lead to detectable effects. Besides such observations, there is a strong demand for systematic investigation of potential interaction mechanisms related to static field exposure during MRI examinations. (orig.)

  10. Ultra-High Field NMR and MRI—The Role of Magnet Technology to Increase Sensitivity and Specificity

    Directory of Open Access Journals (Sweden)

    Ewald Moser

    2017-08-01

    Full Text Available “History, of course, is difficult to write, if for no other reason, than that it has so many players and so many authors.” – P. J. Keating (former Australian Prime MinisterStarting with post-war developments in nuclear magnetic resonance (NMR a race for stronger and stronger magnetic fields has begun in the 1950s to overcome the inherently low sensitivity of this promising method. Further challenges were larger magnet bores to accommodate small animals and eventually humans. Initially, resistive electromagnets with small pole distances, or sample volumes, and field strengths up to 2.35 T (or 100 MHz 1H frequency were used in applications in physics, chemistry, and material science. This was followed by stronger and more stable (Nb-Ti based superconducting magnet technology typically implemented first for small-bore systems in analytical chemistry, biochemistry and structural biology, and eventually allowing larger horizontal-bore magnets with diameters large enough to fit small laboratory animals. By the end of the 1970s, first low-field resistive magnets big enough to accommodate humans were developed and superconducting whole-body systems followed. Currently, cutting-edge analytical NMR systems are available at proton frequencies up to 1 GHz (23.5 T based on Nb3Sn at 1.9 K. A new 1.2 GHz system (28 T at 1.9 K, operating in persistent mode but using a combination of low and high temperature multi-filament superconductors is to be released. Preclinical instruments range from small-bore animal systems with typically 600–800 MHz (14.1–18.8 T up to 900 MHz (21 T at 1.9 K. Human whole-body MRI systems currently operate up to 10.5 T. Hybrid combined superconducting and resistive electromagnets with even higher field strength of 45 T dc and 100 T pulsed, are available for material research, of course with smaller free bore diameters. This rather costly development toward higher and higher field strength is a consequence of the inherently low

  11. Processing and characterization of superconducting solenoids made of Bi-2212/Ag-alloy multifilament round wire for high field magnet applications

    Science.gov (United States)

    Chen, Peng

    As the only high temperature superconductor with round wire (RW) geometry, Bi2Sr2CaCu2O8+x (Bi-2212) superconducting wire has the advantages of being multi-filamentary, macroscopically isotropic and twistable. With overpressure (OP) processing techniques recently developed by our group at the National High Magnetic Field Laboratory (NHMFL), the engineering current density (Je) of Bi-2212 RW can be dramatically increased. For example, Je of more than 600 A/mm 2 (4.2 K and 20 T) is achieved after 100 bar OP processing. With these intrinsically beneficial properties and recent processing progress, Bi-2212 RW has become very attractive for high field magnet applications, especially for nuclear magnetic resonance (NMR) magnets and accelerator magnets etc. This thesis summarizes my graduate study on Bi-2212 solenoids for high field and high homogeneity NMR magnet applications, which mainly includes performance study of Bi-2212 RW insulations, 1 bar and OP processing study of Bi-2212 solenoids, and development of superconducting joints between Bi-2212 RW conductors. Electrical insulation is one of the key components of Bi-2212 coils to provide sufficient electrical standoff within coil winding pack. A TiO 2/polymer insulation offered by nGimat LLC was systematically investigated by differential thermal analysis (DTA), thermo-gravimetric analysis (TGA), scanning electron microscopy (SEM), dielectric property measurements, and transport critical current (Ic) property measurements. About 29% of the insulation by weight is polymer. When the Bi-2212 wire is fully heat treated, this decomposes with slow heating to 400 °C in flowing O2. After the full reaction, we found that the TiO2 did not degrade the critical current properties, adhered well to the conductor, and provided a breakdown voltage of more than 100 V. A Bi-2212 RW wound solenoid coil was built using this insulation being offered by nGimat LLC. The coil resistance was constant through coil winding, polymer burn

  12. High field performance of superconducting magnets using powder metallurgy processed Cu-Nb-Sn and Nb-Al

    Energy Technology Data Exchange (ETDEWEB)

    Zaleski, A.J.; Foner, S.

    1984-06-01

    Small superconducting magnets were fabricated with powder metallurgy processed Nb-Al wire and with powder metallurgy processed multistrand Cu-Nb--Sn wire with 19 tin cores. Tests in a background field of up to 15 T showed that short sample characteristics were achieved for three coils. Upper limits of resistivity were established for both powder metallurgy processed wires. The reacted wires in the magnets gave upper limits of resistivity at 10 T of less than 1.4 x 10/sup -14/ ..cap omega.. cm for the Nb/sub 3/Sn wire, and less than 9 x 10/sup -13/ ..cap omega.. cm for the Nb-Al wire.

  13. High field magnetic resonance microscopy of the human hippocampus in Alzheimer's disease: quantitative imaging and correlation with iron.

    Science.gov (United States)

    Antharam, Vijay; Collingwood, Joanna F; Bullivant, John-Paul; Davidson, Mark R; Chandra, Saurav; Mikhaylova, Albina; Finnegan, Mary E; Batich, Christopher; Forder, John R; Dobson, Jon

    2012-01-16

    We report R(2) and R(2) in human hippocampus from five unfixed post-mortem Alzheimer's disease (AD) and three age-matched control cases. Formalin-fixed tissues from opposing hemispheres in a matched AD and control were included for comparison. Imaging was performed in a 600MHz (14T) vertical bore magnet at MR microscopy resolution to obtain R(2) and R(2) (62 μm×62 μm in-plane, 80 μm slice thickness), and R(1) at 250 μm isotropic resolution. R(1), R(2) and R(2) maps were computed for individual slices in each case, and used to compare subfields between AD and controls. The magnitudes of R(2) and R(2) changed very little between AD and control, but their variances in the Cornu Ammonis and dentate gyrus were significantly higher in AD compared for controls (piron and MRI parameters, each tissue block was cryosectioned at 30 μm in the imaging plane, and iron distribution was mapped using synchrotron microfocus X-ray fluorescence spectroscopy. A positive correlation of R(2) and R(2)* with iron was demonstrated. While studies with fixed tissues are more straightforward to conduct, fixation can alter iron status in tissues, making measurement of unfixed tissue relevant. To our knowledge, these data represent an advance in quantitative imaging of hippocampal subfields in unfixed tissue, and the methods facilitate direct analysis of the relationship between MRI parameters and iron. The significantly increased variance in AD compared for controls warrants investigation at lower fields and in-vivo, to determine if this parameter is clinically relevant.

  14. Analysis of 137 Patients Who Underwent Endoscopic Transsphenoidal Pituitary Adenoma Resection Under High-Field Intraoperative Magnetic Resonance Imaging Navigation.

    Science.gov (United States)

    Zhang, Huaping; Wang, Fuyu; Zhou, Tao; Wang, Peng; Chen, Xiaolei; Zhang, Jiashu; Zhou, Dingbiao

    2017-08-01

    Pure endoscopic resection has become the most popular surgical approach for pituitary adenoma. Intraoperative magnetic resonance imaging (iMRI) systems have been in use for endoscopic resection of pituitary adenomas. This study aimed to evaluate the effectiveness of iMRI and neuroimaging navigation techniques during endoscopic endonasal transsphenoidal surgery of pituitary adenomas. Data from 137 patients who underwent resection of endoscopic pituitary adenoma under 1.5T iMRI navigation were collected and analyzed. Of patients, 92 underwent complete resection and 45 had residual tumor on real-time iMRI. Twenty-three patients underwent further surgery, and total resection was achieved in 19. Extent of total resection increased from 67.15% to 81.02%. iMRI revealed 3 patients with bleeding in the surgical area, which was successfully treated during the surgery. Review images obtained 3 months after surgery showed 26 patients with residual tumor; 14 patients had the same volume as intraoperatively, and 12 patients had a volume less than that observed intraoperatively. Residual tumor volume in the suprasellar region was less than that seen intraoperatively in 11 of 15 (73.3%) patients. The use of iMRI and neuronavigation not only leads to a higher rate of tumor resection but also helps in detecting and removing hematomas in the surgical area. Follow-up examinations of extent of residual tumor at 3 months postoperatively were consistent with intraoperative results. Residual tumor volume in the suprasellar region was usually less than that observed intraoperatively. Copyright © 2017. Published by Elsevier Inc.

  15. High field magnetic transitions in the mixed holmium-yttrium iron garnet Ho(0.43)Y(2.57)Fe(5)O(12).

    Science.gov (United States)

    Bouguerra, A; Khène, S; de Brion, S; Chouteau, G; Fillion, G

    2005-01-12

    High static magnetic field magnetization measurements have been performed up to 23 T on Ho(0.43)Y(2.57)Fe(5)O(12) single crystals at helium temperature (T = 4.2 K) with fields applied along the three main cubic axes: [Formula: see text], [Formula: see text] and [Formula: see text]. The change from the spontaneous ferrimagnetic structure in zero magnetic field to the fully ferromagnetic one in high field takes place through several intermediate phases separated by transitions with step-like magnetization behaviour, but without any observed hysteresis. Using the effective spin Hamiltonian approximation, we show that the general features of these transitions can be accounted for by a large magnetocristalline anisotropy of the Ho(3+) moments of the uniaxial type along the local z axis of each rare-earth site. The model is in better agreement with the experiments than its Ising limit, widely used before, but is still unsuccessful in predicting the 'umbrella' magnetic structures found by previous neutron and NMR experiments.

  16. The design of the inelastic neutron scattering mode for the Extreme Environment Diffractometer with the 26 T High Field Magnet

    Energy Technology Data Exchange (ETDEWEB)

    Bartkowiak, Maciej, E-mail: maciej.bartkowiak@helmholtz-berlin.de; Stüßer, Norbert; Prokhnenko, Oleksandr

    2015-10-11

    The Extreme Environment Diffractometer is a neutron time-of-flight instrument, designed to work with a constant-field hybrid magnet capable of reaching fields over 26 T, unprecedented in neutron science; however, the presence of the magnet imposes both spatial and technical limitations on the surrounding instrument components. In addition to the existing diffraction and small-angle neutron scattering modes, the instrument will operate also in an inelastic scattering mode, as a direct time-of-flight spectrometer. In this paper we present the Monte Carlo ray-tracing simulations, the results of which illustrate the performance of the instrument in the inelastic-scattering mode. We describe the focussing neutron guide and the chopper system of the existing instrument and the planned design for the instrument upgrade. The neutron flux, neutron spatial distribution, divergence distribution and energy resolution are calculated for standard instrument configurations.

  17. Beyond blood brain barrier breakdown – in vivo detection of occult neuroinflammatory foci by magnetic nanoparticles in high field MRI

    Directory of Open Access Journals (Sweden)

    Schnorr Joerg

    2009-08-01

    Full Text Available Abstract Background Gadopentate dimeglumine (Gd-DTPA enhanced magnetic resonance imaging (MRI is widely applied for the visualization of blood brain barrier (BBB breakdown in multiple sclerosis and its animal model, experimental autoimmune encephalomyelitis (EAE. Recently, the potential of magnetic nanoparticles to detect macrophage infiltration by MRI was demonstrated. We here investigated a new class of very small superparamagnetic iron oxide particles (VSOP as novel contrast medium in murine adoptive-transfer EAE. Methods EAE was induced in 17 mice via transfer of proteolipid protein specific T cells. MR images were obtained before and after application of Gd-DTPA and VSOP on a 7 Tesla rodent MR scanner. The enhancement pattern of the two contrast agents was compared, and correlated to histology, including Prussian Blue staining for VSOP detection and immunofluorescent staining against IBA-1 to identify macrophages/microglia. Results Both contrast media depicted BBB breakdown in 42 lesions, although differing in plaques appearances and shapes. Furthermore, 13 lesions could be exclusively visualized by VSOP. In the subsequent histological analysis, VSOP was localized to microglia/macrophages, and also diffusely dispersed within the extracellular matrix. Conclusion VSOP showed a higher sensitivity in detecting BBB alterations compared to Gd-DTPA enhanced MRI, providing complementary information of macrophage/microglia activity in inflammatory plaques that has not been visualized by conventional means.

  18. Beyond blood brain barrier breakdown – in vivo detection of occult neuroinflammatory foci by magnetic nanoparticles in high field MRI

    Science.gov (United States)

    Tysiak, Eva; Asbach, Patrick; Aktas, Orhan; Waiczies, Helmar; Smyth, Maureen; Schnorr, Joerg; Taupitz, Matthias; Wuerfel, Jens

    2009-01-01

    Background Gadopentate dimeglumine (Gd-DTPA) enhanced magnetic resonance imaging (MRI) is widely applied for the visualization of blood brain barrier (BBB) breakdown in multiple sclerosis and its animal model, experimental autoimmune encephalomyelitis (EAE). Recently, the potential of magnetic nanoparticles to detect macrophage infiltration by MRI was demonstrated. We here investigated a new class of very small superparamagnetic iron oxide particles (VSOP) as novel contrast medium in murine adoptive-transfer EAE. Methods EAE was induced in 17 mice via transfer of proteolipid protein specific T cells. MR images were obtained before and after application of Gd-DTPA and VSOP on a 7 Tesla rodent MR scanner. The enhancement pattern of the two contrast agents was compared, and correlated to histology, including Prussian Blue staining for VSOP detection and immunofluorescent staining against IBA-1 to identify macrophages/microglia. Results Both contrast media depicted BBB breakdown in 42 lesions, although differing in plaques appearances and shapes. Furthermore, 13 lesions could be exclusively visualized by VSOP. In the subsequent histological analysis, VSOP was localized to microglia/macrophages, and also diffusely dispersed within the extracellular matrix. Conclusion VSOP showed a higher sensitivity in detecting BBB alterations compared to Gd-DTPA enhanced MRI, providing complementary information of macrophage/microglia activity in inflammatory plaques that has not been visualized by conventional means. PMID:19660125

  19. Beyond blood brain barrier breakdown - in vivo detection of occult neuroinflammatory foci by magnetic nanoparticles in high field MRI.

    Science.gov (United States)

    Tysiak, Eva; Asbach, Patrick; Aktas, Orhan; Waiczies, Helmar; Smyth, Maureen; Schnorr, Joerg; Taupitz, Matthias; Wuerfel, Jens

    2009-08-06

    Gadopentate dimeglumine (Gd-DTPA) enhanced magnetic resonance imaging (MRI) is widely applied for the visualization of blood brain barrier (BBB) breakdown in multiple sclerosis and its animal model, experimental autoimmune encephalomyelitis (EAE). Recently, the potential of magnetic nanoparticles to detect macrophage infiltration by MRI was demonstrated. We here investigated a new class of very small superparamagnetic iron oxide particles (VSOP) as novel contrast medium in murine adoptive-transfer EAE. EAE was induced in 17 mice via transfer of proteolipid protein specific T cells. MR images were obtained before and after application of Gd-DTPA and VSOP on a 7 Tesla rodent MR scanner. The enhancement pattern of the two contrast agents was compared, and correlated to histology, including Prussian Blue staining for VSOP detection and immunofluorescent staining against IBA-1 to identify macrophages/microglia. Both contrast media depicted BBB breakdown in 42 lesions, although differing in plaques appearances and shapes. Furthermore, 13 lesions could be exclusively visualized by VSOP. In the subsequent histological analysis, VSOP was localized to microglia/macrophages, and also diffusely dispersed within the extracellular matrix. VSOP showed a higher sensitivity in detecting BBB alterations compared to Gd-DTPA enhanced MRI, providing complementary information of macrophage/microglia activity in inflammatory plaques that has not been visualized by conventional means.

  20. High-field study of the spin-Peierls system CuGeO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Regnault, L.P. [CEA Centre d`Etudes de Grenoble, 38 (France)

    1997-04-01

    The one-dimensional spin-1/2 Heisenberg antiferromagnetic system coupled to a three-dimensional phonon field undergoes a structural distortion below a finite temperature T{sub sp} (spin-Peierls transition) which induces the formation of a non-magnetic singlet ground-state and the opening of a gap in the excitation spectrum at the antiferromagnetic point. The recent discovery of the germanate CuGeO{sub 3} as a spin-Peierls system has considerably renewed the interest is this fascinating phenomenon. Inelastic neutron scattering and neutron diffraction have brought very quantitative pieces of information which can be directly compared to the predictions of the standard model. (author). 6 refs.

  1. Microstructural parcellation of the human cerebral cortex – from Brodmann's post-mortem map to in vivo mapping with high-field magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Stefan Geyer

    2011-02-01

    Full Text Available The year 2009 marked the 100th anniversary of the publication of the famous brain map of Korbinian Brodmann. Although a "classic" guide to microanatomical parcellation of the cerebral cortex, it is – from today's state-of-the-art neuroimaging perspective – problematic to use Brodmann's map as a structural guide to functional units in the cortex. In this article we discuss some of the reasons, especially the problematic compatibility of the "post-mortem world" of microstructural brain maps with the "in vivo world" of neuroimaging. We conclude with some prospects for the future of in vivo structural brain mapping: a new approach which has the enormous potential to make direct correlations between microstructure and function in living human brains: "in vivo Brodmann mapping" with high-field magnetic resonance imaging.

  2. High field magnetization processes in single crystals of alpha-Tb{sub 2}S{sub 3} and alpha-Dy{sub 2}S{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Ebisu, S; Omote, H; Nagata, S [Department of Materials Science and Engineering, Muroran Institute of Technology, 27-1 Mizumoto-cho, Muroran, Hokkaido 050-8585 (Japan); Koyama, K, E-mail: ebisu@mmm.muroran-it.ac.j [HFLSM, Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2009-03-01

    Rare earth sesquisulfides alpha-Tb{sub 2}S{sub 3} and alpha-Dy{sub 2}S{sub 3} possess orthorhombic crystal structure having two independent rare earth sites. High field magnetization processes for single crystals of these compounds have been investigated up to mu{sub o}H = 18 T. Some step-like transitions have been observed in both compounds. The magnetization of alpha-Tb{sub 2}S{sub 3} single crystal under the field along the 6-axis at T = 1.4 K shows a steep increase of about 4.5 mu{sub B}, which corresponds to a half of full saturation moment of free Tb{sup 3+}, at mu{sub o}H = 2.2 T. It is considered that the reorientation of Tb{sup 3+} moments on only one Tb site into a ferromagnetic arrangement occurs. When the magnetic field is perpendicular to the b-axis, one-step transition at mu{sub o}H = 0.7 T for H||c and two-step transitions at 0.7 and 1.2 T for H||a are observed. As for alpha-Dy{sub 2}S{sub 3}, the magnetization curve at T = 1.5 K shows two-step transitions at 1.3 and 1.6 T (H||b), three or four dull steps (H||a or c). The total height of two steps in the M-H curve for H||b corresponds to a half of full Dy{sup 3+} moment.

  3. High-field EPR spectroscopy of thermal donors in silicon

    DEFF Research Database (Denmark)

    Dirksen, R.; Rasmussen, F.B.; Gregorkiewicz, T.

    1997-01-01

    Thermal donors generated in p-type boron-doped Czochralski-grown silicon by a 450 degrees C heat treatment have been studied by high-field magnetic resonance spectroscopy. In the experiments conducted at a microwave frequency of 140 GHz and in a magnetic field of approximately 5 T four individual...

  4. Combined T2 and T1 measurements for improved perfusion and permeability studies in high field using dynamic contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Bazelaire, Cedric de [Saint Louis Hospital, Radiology Department, Paris, Cedex 10 (France); Beth Israel Deaconess Medical Center and Harvard Medical School, Department of Radiology, Cambridge, MA (United States); Rofsky, Neil M.; Duhamel, Guillaume; Zhang, Jingbo; Alsop, David C. [Beth Israel Deaconess Medical Center and Harvard Medical School, Department of Radiology, Cambridge, MA (United States); Michaelson, M.D. [Massachusetts General Hospital, Department of Hematology/Oncology, Boston, MA (United States); George, Daniel [Dana Farber Cancer Institute, Department of Adult Oncology, Boston, MA (United States)

    2006-09-15

    This study analyzed the T2* effect of extracellularly distributed gadolinium contrast agents in arterial blood during tumor studies using T1-weighted sequences at high field strength. A saturation-prepared dual echo sequence with echo times of 1.5 and 3.5 ms was employed at 3 T to simultaneously characterize T1 and T2* of arterial blood during bolus administration of Gd-DTPA in 28 patients with body tumors. T2* effect and T1 effect of Gd-DTPA on image intensity of whole blood were calibrated in human blood samples with different concentrations of contrast agent. T2* was used to estimate concentration near the peak of the bolus. T1 was used to measure lower concentrations when T2* was not significant. T2* was measurable on calibration curves for Gd-DTPA concentrations higher than 4 mM. This concentration was exceeded in 18 patients. The mean signal intensity reduction because of T2* effect was estimated at 22{+-}14% of the T2* compensated signal. Using T2* measurements reduced underestimations of peak arterial Gd-DTPA concentration (59{+-}38%) and overestimation of permeability K{sup trans} (58%). The T2* effect of gadolinium contrast agents should therefore be accounted for when performing tumors study with T1-weighted sequences at high field strength. (orig.)

  5. Enhanced Field Emission Studies on Niobium Surfaces Relevant to High Field Superconducting Radio-Frequency Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tong [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States)

    2002-09-18

    Enhanced field emission (EFE) presents the main impediment to higher acceleration gradients in superconducting niobium (Nb) radiofrequency cavities for particle accelerators. The strength, number and sources of EFE sites strongly depend on surface preparation and handling. The main objective of this thesis project is to systematically investigate the sources of EFE from Nb, to evaluate the best available surface preparation techniques with respect to resulting field emission, and to establish an optimized process to minimize or eliminate EFE. To achieve these goals, a scanning field emission microscope (SFEM) was designed and built as an extension to an existing commercial scanning electron microscope (SEM). In the SFEM chamber of ultra high vacuum, a sample is moved laterally in a raster pattern under a high voltage anode tip for EFE detection and localization. The sample is then transferred under vacuum to the SEM chamber equipped with an energy-dispersive x-ray spectrometer for individual emitting site characterization. Compared to other systems built for similar purposes, this apparatus has low cost and maintenance, high operational flexibility, considerably bigger scan area, as well as reliable performance. EFE sources from planar Nb have been studied after various surface preparation, including chemical etching and electropolishing, combined with ultrasonic or high-pressure water rinse. Emitters have been identified, analyzed and the preparation process has been examined and improved based on EFE results. As a result, field-emission-free or near field-emission-free surfaces at ~140 MV/m have been consistently achieved with the above techniques. Characterization on the remaining emitters leads to the conclusion that no evidence of intrinsic emitters, i.e., no fundamental electric field limit induced by EFE, has been observed up to ~140 MV/m. Chemically etched and electropolished Nb are compared and no significant difference is observed up to ~140 MV/m. To

  6. Experimental Studies of W-Band Accelerator Structures at High Field

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Marc E

    2001-02-09

    A high-gradient electron accelerator is desired for high-energy physics research, where frequency scalings of breakdown and trapping of itinerant beamline particles dictates operation of the accelerator at short wavelengths. The first results of design and test of a high-gradient mm-wave linac with an operating frequency at 91.392 GHz (W-band) are presented. A novel approach to particle acceleration is presented employing a planar, dielectric lined waveguide used for particle acceleration. The traveling wave fields in the planar dielectric accelerator (PDA) are analyzed for an idealized structure, along with a circuit equivalent model used for understanding the structure as a microwave circuit. Along with the W-band accelerator structures, other components designed and tested are high power rf windows, high power attenuators, and a high power squeeze-type phase shifter. The design of the accelerator and its components where eased with the aide of numerical simulations using a finite-difference electromagnetic field solver. Manufacturing considerations of the small, delicate mm-wave components and the steps taken to reach a robust fabrication process are detailed. These devices were characterized under low power using a two-port vector network analyzer to verify tune and match, including measurements of the structures' fields using a bead-pull. The measurements are compared with theory throughout. Addition studies of the W-band structures were performed under high power utilizing a 11.424 GHz electron linac as a current source. Test results include W-band power levels of 200 kW, corresponding to fields in the PDA of over 20 MV/m, a higher gradient than any collider. Planar accelerator devices naturally have an rf quadrupole component of the accelerating field. Presented for the first time are the measurements of this effect.

  7. Chemical spray pyrolysis of Tl-Ba-Ca-Cu-O high-T(sub c) superconductors for high-field bitter magnets

    Science.gov (United States)

    Derochemont, L. Pierre; Zhang, John G.; Squillante, Michael R.; Hermann, A. M.; Duan, H. M.; Andrews, Robert J.; Kelliher, Warren C.

    1991-01-01

    The deposition of Tl-Ba-Ca-Cu-O thick films by spray pyrolyzing a Ba-Ca-Cu-O precursor film and diffusing thallium into the film to form the superconducting phase is examined. This approach was taken to reduce exposure to thallium and its health and safety hazards. The Tl-Ba-Ca-Cu-O system was selected because it has very attractive features which make it appealing to device and manufacturing engineering. Tl-Ba-Ca-Cu-O will accommodate a number of superconducting phases. This attribute makes it very forgiving to stoichiometric fluctuations in the bulk and film. It has excellent thermal and chemical stability, and appears to be relatively insensitive to chemical impurities. Oxygen is tightly bound into the systems, consequently there is no orthorhombic (conductor) to tetragonal (insulator) transition which would affect a component's lifetime. More significantly, the thallium based superconductors appear to have harder magnetic properties than the other high-Tc oxide ceramics. Estimates using magnetoresistance measurements indicate that at 77 K Tl2Ba2CaCu2O10 will have an upper critical field, H(sub c2) fo 26 Tesla for applied fields parallel to the c-axis and approximately 1000 Tesla for fields oriented in the a-b plane. Results to date have shown that superconducting films can be reproducibly deposited on 100 oriented MgO substrates. One film had a zero resistance temperature of 111.5 K. Furthermore, x ray diffraction analysis of the films showed preferential c-axis orientation parallel to the plane of the substrate. These results have now made it possible to consider the manufacture of a superconducting tape wire which can be configured into a topology useful for high-field magnet designs. The research which leads to the preparation of these films and plans for further development are reviewed.

  8. Assessment of age-related morphometric changes of subcortical structures in healthy people using ultra-high field 7 tesla magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Xueyuan Wang

    2016-09-01

    Full Text Available Objective: To assess the age-related morphometric changes of subcortical structures in healthy people.Material and Methods: Ultra-high field 7 tesla magnetic resonance imaging in humans was used to visualize the subcortical structures of healthy young, middle-aged, and elderly participants. Using the magnetization-prepared two rapid acquisition gradient echoes sequence, we assessed the visibility of the margins of the thalamus and white matter in the thalamus, as well as the anterior commissure (AC and posterior commissure (PC length, the maximal height of the thalamus, the half width of third ventricle, and the distance between the AC and the center of the mammillothalamic tract at the level of the AC-PC plane. All quantitative data were statistically evaluated.Results: The AC-PC length did not differ significantly among the three groups. The maximal height of the thalamus decreased with age (rs(53=-0.719, p<0.001. The half width of the third ventricle (rs(53=0.705, p<0.001 and the distance between the AC and the center of the mammillothalamic tract (MTT (rs(53=0.485, p<0.001 increased with age. The distance between the AC and the center of the MTT of the young and the elderly participants differed significantly (p=0.007.Conclusion: The AC-PC length is not a good candidate for proportional correction during atlas-to-patient registration. The maximal height of the thalamus and the half width of the third ventricle correlated strongly with age, and the MTT position in relation to the AC shifted posteriorly as age increased. These age-related morphometric changes of subcortical structures should be considered in targeting for functional neurosurgery.

  9. Low-field and high-field magnetic resonance contrast imaging of magnetoferritin as a pathological model system of iron accumulation

    Science.gov (United States)

    Strbak, Oliver; Balejcikova, Lucia; Baciak, Ladislav; Kovac, Jozef; Masarova-Kozelova, Marta; Krafcik, Andrej; Dobrota, Dusan; Kopcansky, Peter

    2017-09-01

    Various pathological processes including neurodegenerative disorders are associated with the accumulation of iron, while it is believed that a precursor of iron accumulation is ferritin. Physiological ferritin is due to low relaxivity, which results in only weak detection by magnetic resonance imaging (MRI) techniques. On the other hand, pathological ferritin is associated with disrupted iron homeostasis and structural changes in the mineral core, and should increase the hypointensive artefacts in MRI. On the basis of recent findings in respect to the pathological ferritin structure, we prepared the magnetoferritin particles as a possible pathological ferritin model system. The particles were characterised with dynamic light scattering, as well as with superconducting quantum interference device measurements. With the help of low-field (0.2 T) and high-field (4.7 T) MRI standard T 2-weighted protocols we found that it is possible to clearly distinguish between native ferritin as a physiological model system, and magnetoferritin as a pathological model system. Surprisingly, the T 2-weighted short TI inversion recovery protocol at low-field system showed the optimum contrast differentiation. Such findings are highly promising for exploiting the use of iron accumulation as a noninvasive diagnostics tool of pathological processes, where the magnetoferritin particles could be utilised as MRI iron quantification calibration samples.

  10. A high-field magnetic resonance imaging spectrometer using an oven-controlled crystal oscillator as the local oscillator of its radio frequency transceiver.

    Science.gov (United States)

    Liang, Xiao; Tang, Xin; Tang, Weinan; Gao, Jia-Hong

    2014-09-01

    A home-made high-field magnetic resonance imaging (MRI) spectrometer with multiple receiving channels is described. The radio frequency (RF) transceiver of the spectrometer consists of digital intermediate frequency (IF) circuits and corresponding mixing circuits. A direct digital synthesis device is employed to generate the IF pulse; the IF signal from a down-conversion circuit is sampled and followed by digital quadrature detection. Both the IF generation and the IF sampling use a 50 MHz clock. An oven-controlled crystal oscillator, which has outstanding spectral purity and a compact circuit, is used as the local oscillator of the RF transceiver. A digital signal processor works as the pulse programmer of the spectrometer, as a result, 32 control lines can be generated simultaneously while an event is triggered. Field programmable gate array devices are utilized as the auxiliary controllers of the IF generation, IF receiving, and gradient control. High performance, including 1 μs time resolution of the soft pulse, 1 MHz receiving bandwidth, and 1 μs time resolution of the gradient waveform, is achieved. High-quality images on a 1.5 T MRI system using the spectrometer are obtained.

  11. First-principle theory of high field carrier transport in semiconductors with application to the study of avalanche photodiodes

    Science.gov (United States)

    Moresco, Michele

    2011-12-01

    The objective of this thesis work is twofold: to present a theoretical framework to study high-field carrier transport in semiconductor materials and to provide a deep understanding of the transport properties of GaN and HgCdTe. The validation of this model is performed by applying it to the study of Avalanche Photodiodes. The model we developed is based on Monte Carlo techniques and it includes the full details of the band structure, derived from the empirical pseudopotential method (EPM), and a numerically calculated impact ionization transition rate based on a wave-vector dependent dielectric function. The nonpolar carrier-phonon interaction is treated within the framework of the rigid pseudoion (RPI) approximation using ab initio techniques to determine the phonon dispersion relation. The calculated phonon scattering rates are consistent with the electronic structure and the phonon dispersion relation thus removing adjustable parameters such as deformation potential coefficients. Band-to-band carrier tunneling has been treated by solving the time-dependent multiband Schroedinger equation. The multiband description predicts a considerable increase of the impact ionization coefficients compared with simulations not considering tunneling. Specifically, the present model has been applied to the study of two distinct semiconductor materials: GaN and HgCdTe. The former is a wide bandgap while the second is a narrow bandgap semiconductor. In spite of their constantly increasing technological reliability both materials lack theoretical understanding of high-field carrier transport. Avalanche photodiodes (APDs) offer an ideal environment to test and validate the model developed in this thesis work because of the large electric field involved in these devices. APDs based on both GaN and HgCdTe are investigated, consistently with the physics-based models described above. Key quantities such as gain, breakdown voltage, bandwidth and noise characteristics are estimated. The

  12. A study of high field quantum electrodynamics in the collision of high energy electrons with a terawatt laser

    Energy Technology Data Exchange (ETDEWEB)

    Horton-Smith, G.A.

    1998-07-01

    An experiment is described which studied quantum electrodynamic interactions under conditions of extremely high fields, along with a review of the relevant theory. The high fields were created by an intense, tightly-focused pulse of laser light at green or infrared wavelengths, into which was sent an ultra-relativistic electron beam of 46.6-GeV energy. The relevant theory is that of an electron in an electromagnetic wave so intense that the electron's mass is effectively shifted by the transverse momentum imparted to it by the wave, and the electron encounters field strengths comparable to the Schwinger critical field strength of 511 kV per Compton wavelength. An electron in the intense wave may radiate a photon and balance 4-momentum by absorbing multiple photons from the laser, which can lead to real photons with energies above the kinematic limit for conventional Compton scattering. All particles have significant probability of scattering multiple times while in the focus of the laser, including the photons radiated by the electrons, which may convert into electron-positron pairs, again with absorption of multiple photons from the laser. This experiment was able to measure the rates and spectra of positrons, electrons, and photons emerging from the interaction region. Results from both experiment and theoretical simulations are presented and compared. The results from the electron and positron measurements are compatible with the accepted theory, within experimental uncertainties due mainly to the laser intensity measurement. The photon spectrum shows the correct shape, but the ratio of rates in the linear and two-absorbed-photon portions of the spectrum does not vary as expected with the laser intensity, suggesting a disagreement with the accepted theory, with a significance of roughly two standard deviations. A follow-up experiment would be in order.

  13. High-field magnetization of a two-dimensional spin frustration system, Ni{sub 5}(TeO{sub 3}){sub 4}X{sub 2} (X = Br, Cl)

    Energy Technology Data Exchange (ETDEWEB)

    Her, J L; Matsuda, Y H; Suga, K; Kindo, K; Takeyama, S [Institute for Solid State Physics, University of Tokyo (Japan); Berger, H [Institutes of Physics of Complex Matter, EPFL, Lausanne (Switzerland); Yang, H D [Department of Physics, Center for Nanoscience and Nanotechnology, National Sun Yat-sen University, Taiwan (China)

    2009-10-28

    The high-field magnetization, M(H), of Ni{sub 5}(TeO{sub 3}){sub 4}X{sub 2} (X = Br, Cl) was measured by using a pulse magnet. These compounds have a two-dimensional crystal structure and a distorted Kagome spin frustrated system which is built from the Ni{sup 2+} ions (S = 1). The Neel transition temperatures are T{sub N}approx28 and 23 K for X = Br and Cl, respectively. When TT{sub N}, the field-dependent magnetization curves behave like a monotonically increasing straight line up to 55 T. The H{sub c} value is close to those obtained in previous spin resonance studies in which a model of a spin-flop scenario was proposed to explain the field-dependent resonance spectra. With the earlier model a further transition at around 23 T was predicted; however, our observations did not show any plateau behaviors, saturation or other anomalies up to 55 T, suggesting that the further transition possibly exists in a much higher field region.

  14. The effects of the use of piezoelectric motors in a 1.5-Tesla high-field magnetic resonance imaging system (MRI).

    Science.gov (United States)

    Wendt, O; Oellinger, J; Lüth, T C; Felix, R; Boenick, U

    2000-01-01

    This paper presents the results of an experimental investigation with two different rotatory piezomotors in a closed 1.5 Tesla high-field MRI. The focus of the investigation was on testing the functionality of these motors within the MRI and to determining the image interference they caused. To obtain a differentiated estimate of the interference the motors were tested in both the passive (turned off, i.e. without current flow) and active (turned on, i.e. with current flow) state during MRI scanning. Three different types of sequences were used for the test: Spin-Echo (SE), Gradient-Echo (GE) and Echo-Planar Imaging (EPI). A plastic container filled with a gadolinium-manganese solution was used for representation of the artefacts. The motors investigated were placed parallel to the container at predetermined distances during the experiment. The results show that the motors investigated suffered no functional limitations in the magnetic field of the MRI but, depending on the type of motor, the measurement distance and the state of the motor, the motors had different effects on the sequence images. A motor in the off-state placed immediately next to the object to be measured mainly causes artefacts because of its material properties. If, on the other hand, the piezomotor is in the on-state images with strong noise result when the motor is immediately next to the object being measured. The images regain their normal quality when the motor is approximately at a distance of 1 m from the object being investigated. Driving the motor inside the MRI, therefore, is only to be recommended during the pauses in scanning: this delivers artefact-free images if minimal, motor-specific distances are kept to. With regard to the three different types of sequences it was determined that the SE sequence was the least sensitive and the EPI sequence the most sensitive to disturbance. The GE sequence showed only minimal differences to the SE sequence with regard to signal-to-noise ratios

  15. Magnetic resonance imaging of hindfoot involvement in patients with spondyloarthritides: comparison of low-field and high-field strength units.

    Science.gov (United States)

    Eshed, Iris; Althoff, Christian E; Feist, Eugen; Minden, Kirsten; Schink, Tania; Hamm, Bernd; Hermann, Kay-Geert A

    2008-01-01

    To compare MRI evaluation of a painful hindfoot of patients with spondyloarthritides (SpA) on low-field (0.2 T) versus high-field (1.5 T) MRI. Patients with SpA and hindfoot pain were randomly referred to either high-field or low-field MRI. Twenty-seven patients were evaluated (male/female: 17:10; mean age: 39+/-1.4 years). Fifteen patients were examined by low-field and 12 by high-field MRI. Two patients (evaluated by high-field MRI) were excluded. Images were separately read by two radiologists who later reached a consensus. In each patient the prevalence of erosions, fluid, synovitis or bone marrow edema of the hindfoot joints, tendinosis or tenosynovitis of tendons, enthesitis of the plantar fascia and Achilles tendon and retrocalcaneal bursitis were recorded. Clinical and demographic parameters were comparable between both groups. MRI evaluation of joints and tendons of the hindfoot revealed no significant differences in patients with SpA groups for all parameters. Analyzing all joints or tendons together, there was no statistically significant difference between the two groups. Low-field and high-field MRI provide comparable information for evaluation of inflammatory hindfoot involvement. Thus, low-field MRI can be considered as a reliable diagnostic tool for the detection of hindfoot abnormalities in SpA patients.

  16. Magnetic resonance imaging of hindfoot involvement in patients with spondyloarthritides: Comparison of low-field and high-field strength units

    Energy Technology Data Exchange (ETDEWEB)

    Eshed, Iris; Althoff, Christian E. [Department of Radiology, Charite Medical School, Berlin (Germany); Feist, Eugen [Department of Rheumatology and Clinical Immunology, Charite Medical School, Berlin (Germany); Minden, Kirsten [Helios Clinics, 2nd Children' s Hospital Berlin-Buch, Rheumatology Unit, Berlin (Germany); German Rheumatology Research Center, Berlin (Germany); Schink, Tania [Department of Medical Biometry, Charite Medical School, Berlin (Germany); Hamm, Bernd [Department of Radiology, Charite Medical School, Berlin (Germany); Hermann, Kay-Geert A. [Department of Radiology, Charite Medical School, Berlin (Germany)], E-mail: kgh@charite.de

    2008-01-15

    Objective: To compare MRI evaluation of a painful hindfoot of patients with spondyloarthritides (SpA) on low-field (0.2 T) versus high-field (1.5 T) MRI. Materials and methods: Patients with SpA and hindfoot pain were randomly referred to either high-field or low-field MRI. Twenty-seven patients were evaluated (male/female: 17:10; mean age: 39 {+-} 1.4 years). Fifteen patients were examined by low-field and 12 by high-field MRI. Two patients (evaluated by high-field MRI) were excluded. Images were separately read by two radiologists who later reached a consensus. In each patient the prevalence of erosions, fluid, synovitis or bone marrow edema of the hindfoot joints, tendinosis or tenosynovitis of tendons, enthesitis of the plantar fascia and Achilles tendon and retrocalcaneal bursitis were recorded. Clinical and demographic parameters were comparable between both groups. Results: MRI evaluation of joints and tendons of the hindfoot revealed no significant differences in patients with SpA groups for all parameters. Analyzing all joints or tendons together, there was no statistically significant difference between the two groups. Conclusion: Low-field and high-field MRI provide comparable information for evaluation of inflammatory hindfoot involvement. Thus, low-field MRI can be considered as a reliable diagnostic tool for the detection of hindfoot abnormalities in SpA patients.

  17. High-field magnetic resonance imaging of structural alterations in first-episode, drug-naive patients with major depressive disorder.

    Science.gov (United States)

    Chen, Z; Peng, W; Sun, H; Kuang, W; Li, W; Jia, Z; Gong, Q

    2016-11-08

    Previous structural imaging studies have found evidence of brain morphometric changes in patients with major depressive disorder (MDD), but these studies rarely excluded compounding effects of certain important factors, such as medications and long duration of illnesses. Furthermore, the neurobiological mechanism of the macroscopic findings of structural alterations in MDD patients remains unclear. In this study, we utilized magnetization transfer imaging, a quantitative measure of the macromolecular structural integrity of brain tissue, to identify biophysical alterations, which are represented by a magnetization transfer ratio (MTR), in MDD patients. To ascertain whether MTR changes occur independent of volume loss, we also conduct voxel-based morphometry (VBM) analysis. The participants included 27 first-episode, drug-naive MDD patients and 28 healthy controls matched for age and gender. Whole-brain voxel-based analysis was used to compare MTR and gray matter volume across groups and to analyse correlations between MTR and age, symptom severity, and illness duration. The patients exhibited significantly lower MTR in the left superior parietal lobule and left middle occipital gyrus compared with healthy controls, which may be related to the attentional and cognitive dysfunction in MDD patients. The VBM analysis revealed significantly increased gray matter volume in right postcentral gyrus in MDD patients. These findings in first-episode, drug-naive MDD patients may reflect microstructural gray matter changes in the parietal and occipital cortices close to illness onset that existed before volume loss, and thus potentially provide important new insight into the early neurobiology of depression.

  18. Age dependency of myocardial triglyceride content. A 3T high-field {sup 1}H-MR spectroscopy study

    Energy Technology Data Exchange (ETDEWEB)

    Petritsch, B.; Gassenmaier, T.; Kunz, A.S.; Donhauser, J.; Bley, T.A.; Horn, M. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology; Goltz, J.P. [University Hospital of Schleswig-Holstein, Campus Luebeck (Germany). Clinic for Radiology and Nuclear Medicine

    2015-11-15

    The role of myocardial triglyceride (mTG) content in the aging human heart is not entirely understood. The aim of this study was to measure concentrations of mTG content from healthy volunteers and to determine the association between age, mTG content and systolic heart function. Furthermore, the technical stability of the {sup 1}H-magnetic resonance spectroscopy ({sup 1}H-MRS) and the reliability of peak evaluation at 3 T were evaluated. The total study population of 47 healthy volunteers was divided into 4 age classes, according to the age of the subjects (1{sup st} cohort 20-29 years (yrs.), n=20; 2{sup nd} cohort 30-39 yrs., n=10; 3{sup rd} cohort 40-49 yrs., n=9; 4{sup th} cohort 50-60 yrs., n=8). Cardiac MRI and double triggered {sup 1}H-MRS of the myocardium were consecutively performed using a 3 T scanner. Each participant underwent spectroscopic measurements twice in the same investigation. mTG content increases with age. The correlation of age and mTG is minimal (r=0.48; p<0.001). The following age-averaged mTG content values expressed as % of mTG signal compared to the water signal were determined for each cohort: 1{sup st} cohort 0.25 % (± 0.17); 2{sup nd} cohort 0.48 % (± 0.30); 3{sup rd} cohort 0.48 % (± 0.18); 4{sup th} cohort 0.77 % (± 0.70). There was no significant correlation (r=0.04; p=n.s.) between LV mass and mTG content in healthy volunteers. Within our cohorts, no effects of age or mTG content on systolic heart function were seen (r=-0.01; p=n.s.). The intraclass correlation coefficient of spectroscopic measurements was high (r=0.965; p<0.001). Myocardial TG content increases with age. The normal age-dependent concentration ranges of myocardial lipid metabolites reported in this study may be helpful for the correction of acquired {sup 1}H-MRS data in patients when evaluating metabolic and cardiovascular diseases in future magnetic resonance spectroscopy studies.

  19. High-resolution T2-weighted cervical cancer imaging: a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna.

    Science.gov (United States)

    Hoogendam, Jacob P; Kalleveen, Irene M L; de Castro, Catalina S Arteaga; Raaijmakers, Alexander J E; Verheijen, René H M; van den Bosch, Maurice A A J; Klomp, Dennis W J; Zweemer, Ronald P; Veldhuis, Wouter B

    2017-03-01

    We studied the feasibility of high-resolution T2-weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. A feasibility study on 20 stage IB1-IIB cervical cancer patients was conducted. All underwent pre-treatment 1.5-T MRI. At 7.0-T MRI, an external transmit/receive array with seven dipole antennae and a single endorectal monopole receive antenna were used. Discomfort levels were assessed. Following individualised phase-based B1(+) shimming, T2-weighted turbo spin echo sequences were completed. Patients had stage IB1 (n = 9), IB2 (n = 4), IIA1 (n = 1) or IIB (n = 6) cervical cancer. Discomfort (ten-point scale) was minimal at placement and removal of the endorectal antenna with a median score of 1 (range, 0-5) and 0 (range, 0-2) respectively. Its use did not result in adverse events or pre-term session discontinuation. To demonstrate feasibility, T2-weighted acquisitions from 7.0-T MRI are presented in comparison to 1.5-T MRI. Artefacts on 7.0-T MRI were due to motion, locally destructive B1 interference, excessive B1 under the external antennae and SENSE reconstruction. High-resolution T2-weighted 7.0-T MRI of stage IB1-IIB cervical cancer is feasible. The addition of an endorectal antenna is well tolerated by patients. • High resolution T 2 -weighted 7.0-T MRI of the inner female pelvis is challenging • We demonstrate a feasible approach for T 2 -weighted 7.0-T MRI of cervical cancer • An endorectal monopole receive antenna is well tolerated by participants • The endorectal antenna did not lead to adverse events or session discontinuation.

  20. Atomic scale structure of amorphous aluminum oxyhydroxide, oxide and oxycarbide films probed by very high field (27)Al nuclear magnetic resonance.

    Science.gov (United States)

    Baggetto, L; Sarou-Kanian, V; Florian, P; Gleizes, A N; Massiot, D; Vahlas, C

    2017-03-15

    The atomic scale structure of aluminum in amorphous alumina films processed by direct liquid injection chemical vapor deposition from aluminum tri-isopropoxide (ATI) and dimethyl isopropoxide (DMAI) is investigated by solid-state (27)Al nuclear magnetic resonance (SSNMR) using a very high magnetic field of 20.0 T. This study is performed as a function of the deposition temperature in the range 300-560 °C, 150-450 °C, and 500-700 °C, for the films processed from ATI, DMAI (+H2O), and DMAI (+O2), respectively. While the majority of the films are composed of stoichiometric aluminum oxide, other samples are partially or fully hydroxylated at low temperature, or contain carbidic carbon when processed from DMAI above 500 °C. The quantitative analysis of the SSNMR experiments reveals that the local structure of these films is built from AlO4, AlO5, AlO6 and Al(O,C)4 units with minor proportions of the 6-fold aluminum coordination and significant amounts of oxycarbides in the films processed from DMAI (+O2). The aluminum coordination distribution as well as the chemical shift distribution indicate that the films processed from DMAI present a higher degree of structural disorder compared to the films processed from ATI. Hydroxylation leads to an increase of the 6-fold coordination resulting from the trend of OH groups to integrate into AlO6 units. The evidence of an additional environment in films processed from DMAI (+O2) by (27)Al SSNMR and first-principle NMR calculations on Al4C3 and Al4O4C crystal structures supports that carbon is located in Al(O,C)4 units. The concentration of this coordination environment strongly increases with increasing process temperature from 600 to 700 °C favoring a highly disordered structure and preventing from crystallizing into γ-alumina. The obtained results are a valuable guide to the selection of process conditions for the CVD of amorphous alumina films with regard to targeted applications.

  1. High field superconducting magnet: Science, Technology and Applications%高场超导磁体科学技术与应用

    Institute of Scientific and Technical Information of China (English)

    王秋良

    2013-01-01

    科学技术的发展对于磁场强度质量的要求越来越高,极端强磁场条件是人类追求的永远的科学目标,它孕育着许多重大的科学发现和新技术的产生,对人类的科学和技术以及生活产生重大的影响.以磁体为核心与电力电子器件以及相关的软件等结合可以构成各种各样科学仪器和装置,广泛应用在科学研究和工业特种装备中.磁技术对于人类的科学与技术进步起到越来越重要的作用,尤其是极高磁场所带来的诸多优点,使得人类对于物质世界认识不断加深,对于生命的起源以及从事疾病的防治的研究有特别重要的意义.本文介绍磁体基本原理、磁场产生的方法与应用以及相关的发展.%Development of superconducting magnet science and technology requires a magnetic field with high strength and good quality.The pursuit of extremely high magnetic field is an eternal scientific goal forscientists and engineers.It is an exciting cutting-edge technology with full of challenges and has been essential for many significant discoveries in science and technology.Combined with power-electronic devices and related software,a whole magnet system can be built up as the key component of various types of scientific instruments and other equipment,and can be fund widespread applications in scientific research and industry.Magnet technology is currently playing a more and more important role in scientific and technological progress.Ultra-high magnetic fields help to give us much deeper understanding of the world of matter and have special significance for research into the origins of life and disease prevention.In this review article,basic magnet principles,methods of generating magnetic fields,magnetic field applications,and numerical methods for the design of magnet structures are briefly introduced and reviewed.

  2. High-field ELDOR-detected NMR study of a nitroxide radical in disordered solids: Towards characterization of heterogeneity of microenvironments in spin-labeled systems

    Science.gov (United States)

    Nalepa, Anna; Möbius, Klaus; Lubitz, Wolfgang; Savitsky, Anton

    2014-05-01

    The combination of high-field EPR with site-directed spin-labeling (SDSL) techniques employing nitroxide radicals has turned out to be particularly powerful in probing the polarity and proticity characteristics of protein/matrix systems. This information is concluded from the principal components of the nitroxide Zeeman (g), nitrogen hyperfine (A) and quadrupole (P) tensors of the spin labels attached to specific sites. Recent multi-frequency high-field EPR studies underlined the complexity of the problem to treat the nitroxide microenvironment in proteins adequately due to inherent heterogeneities which result in several principal x-components of the nitroxide g-tensor. Concomitant, but distinctly different nitrogen hyperfine components could, however, not be determined from high-field cw EPR experiments owing to the large intrinsic EPR linewidth in fully protonated guest/host systems. It is shown in this work that, using the W-band (95 GHz) ELDOR- (electron-electron double resonance) detected NMR (EDNMR) method, different principal nitrogen hyperfine, Azz, and quadrupole, Pzz, tensor values of a nitroxide radical in glassy 2-propanol matrix can be measured with high accuracy. They belong to nitroxides with different hydrogen-bond situations. The satisfactory resolution and superior sensitivity of EDNMR as compared to the standard ENDOR (electron-nuclear double resonance) method are demonstrated.

  3. Band-Structure Effects in the High-Field Magnetization of Pd and Dilute Pd-Rh and Pd-Ag Alloys

    DEFF Research Database (Denmark)

    Andersen, O. Krogh

    1970-01-01

    be derived solely from the band density of states N(E). The previously reported Pd band-structure calculations, which were in excellent agreement with the de Haas-van Alphen data, have been extended to yield DeltaB(sigma) for Pd and, using the rigid band model, also for dilute Pd[Single Bond]Rh and Pd......From Stoner theory we show that the magnetic field-vs-spin magnetization has the form B(sigma)=sigma/chi(0)+DeltaB(sigma). The low-field susceptibility chi(0) is exchange-enhanced but, if the effective exchange potential does not depend on magnetization, the deviation from linearity DeltaB may......; moreover, the experimental data have previously been analyzed according to a power series expansion of sigma(B) that neither separates the effect of band structure from that of exchange enhancement nor applies when van Hove singularities are important. Our formulation suggests a way of analyzing...

  4. Electron-mediating Cu(A) centers in proteins: a comparative high field (1)H ENDOR study.

    Science.gov (United States)

    Epel, Boris; Slutter, Claire S; Neese, Frank; Kroneck, Peter M H; Zumft, Walter G; Pecht, Israel; Farver, Ole; Lu, Yi; Goldfarb, Daniella

    2002-07-10

    High field (W-band, 95 GHz) pulsed electron-nuclear double resonance (ENDOR) measurements were carried out on a number of proteins that contain the mixed-valence, binuclear electron-mediating Cu(A) center. These include nitrous oxide reductase (N(2)OR), the recombinant water-soluble fragment of subunit II of Thermus thermophilus cytochrome c oxidase (COX) ba(3) (M160T9), its M160QT0 mutant, where the weak axial methionine ligand has been replaced by a glutamine, and the engineered "purple" azurin (purpAz). The three-dimensional (3-D) structures of these proteins, apart from the mutant, are known. The EPR spectra of all samples showed the presence of a mononuclear Cu(II) impurity with EPR characteristics of a type II copper. At W-band, the g( perpendicular) features of this center and of Cu(A) are well resolved, thus allowing us to obtain a clean Cu(A) ENDOR spectrum. The latter consists of two types of ENDOR signals. The first includes the signals of the four strongly coupled cysteine beta-protons, with isotropic hyperfine couplings, A(iso), in the 7-15 MHz range. The second group consists of weakly coupled protons with a primarily anisotropic character with A(zz) < 3 MHz. Orientation selective ENDOR spectra were collected for N(2)OR, M160QT0, and purpAz, and simulations of the cysteine beta-protons signals provided their isotropic and anisotropic hyperfine interactions. A linear correlation with a negative slope was found between the maximum A(iso) value of the beta-protons and the copper hyperfine interaction. Comparison of the best-fit anisotropic hyperfine parameters with those calculated from dipolar interactions extracted from the available 3-D structures sets limit to the sulfur spin densities. Similarly, the small coupling spectral region was simulated on the basis of the 3-D structures and compared with the experimental spectra. It was found that the width of the powder patterns of the weakly coupled protons recorded at g(perpendicular) is mainly

  5. Specific proof of various stages of Osler's disease of the brain via high field magnetic resonance tomography (1. 5 Tesla)

    Energy Technology Data Exchange (ETDEWEB)

    Billet, F.; Bluemm, R.G.; Beyer, H.K.

    1988-08-01

    MR is a sensitive noninvasive examination method for diagnosing parenchymatous cryptic arteriovenous malformations and sequels of cerebral haemorrhage. In a patient with recurring nosebleed and brain stem syndrome eleven so-called cryptic arteriovenous malformations or their haemorrhage sequels were diagnosed via magnetic resonance tomography. Basing on these specific findings, nosebleeding, and a positive family anamnesis, the findings could be classified as belonging to manifestations of Osler's disease (hereditary haemorrhagic telangiectasia). This rare disease is characterised by a triad of signs: telangiectasias, recurring bleeding, and heredity. In this article the specific MR image is compared with the CT pattern and the results are discussed against the background of literature on Osler's disease which is also known as Rendu-Osler-Weber disease.

  6. Optimizing brain tumor resection. High-field interventional MR imaging.

    Science.gov (United States)

    Tummala, R P; Chu, R M; Liu, H; Truwit, C L; Hall, W A

    2001-11-01

    High-field strength iMRI guidance is an effective tool for brain tumor resection. Although its use lengthens the average time for a craniotomy, the reward is a more extensive tumor excision compared with conventional neurosurgery without an increased risk to the patient (Table 4). Although intraoperative patient transfer into and out of the magnet is cumbersome, the possibility for complete resection, especially for a low-grade glioma, makes the effort worthwhile. The cost and technical support required for this system presently limits its use to only a few sites worldwide. As with any technology, further refinements will make this system less expensive and more attainable. Practical consideration aside, high-field strength iMRI is presently [table: see text] the most effective tool available for brain tumor resection. Because of its novelty, future studies are necessary to determine if this technology lowers the incidence of and extends the duration to tumor recurrence as the preliminary data in children suggests. These are the ultimate measures of efficacy for any brain tumor treatment. Based on the rapid advancement of technology, will today's high-field strength interventional magnet become tomorrow's low-field system? Very high-field strength designs may improve diagnostic capabilities through higher resolution, but their interventional applications may be hindered by increased sensitivity for clinically insignificant abnormalities and decreased specificity for clinically relevant lesions. As new technology is developed, clinicians must continue to explore and refine the existing high-field strength iMRI to make it cost-effective and widely applicable.

  7. Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: feasibility, handling, and needle artefacts

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, Jens-Peter; Langner, Soenke; Hegenscheid, Katrin; Hosten, Norbert; Puls, Ralf [Ernst Moritz Arndt University of Greifswald, Department of Radiology, Greifswald (Germany); Evert, Matthias [Ernst Moritz Arndt University of Greifswald, Department of Pathology, Greifswald (Germany); Kickhefel, Antje [Siemens Healthcare, Erlangen (Germany)

    2010-10-15

    To investigate the feasibility and handling of abdominal MRI-guided biopsies in a 3-T MRI system. Over a 1-year period, 50 biopsies were obtained in 47 patients with tumours of the upper abdominal organs guided by 3-T MRI with a large-bore diameter of 70 cm. Lesions in liver (47), spleen (1) and kidney (2) were biopsied with a coaxial technique using a 16-G biopsy needle guided by a T1-weighted three-dimensional gradient recalled echo volumetric interpolated breath-hold examination (T1w-3D-GRE-VIBE) sequence. Sensitivity, specificity, accuracy, complication rate, interventional complexity, room/intervention time and needle artefacts were determined. A sensitivity of 0.93, specificity of 1.0 and accuracy of 0.94 were observed. Three patients required a rebiopsy. There was a minor complications rate of 13.6%, and no major complications were observed. Histopathology revealed 38 malignant lesions, and 3-month follow-up confirmed 9 benign lesions. Mean lesion diameter was 3.4 {+-} 3.1 cm (50% being smaller than 2 cm). Mean needle tract length was 10.8 {+-} 3.3 cm. Median room time was 42.0 {+-} 19.8 min and intervention time 9.3 {+-} 8.1 min. Needle artefact size was about 9-fold greater for perpendicular access versus access parallel to the main magnetic field. Biopsies of the upper abdomen can be performed with great technical success and easy handling because of the large-bore diameter. The MRI-guided biopsy needle had an acceptable susceptibility artefact at 3 T. However future research must aim to reduce the susceptibility effects of the biopsy systems. (orig.)

  8. High-field phase transitions and Fermi surfaces in the organic conductor α-(BEDT-TTF) 2KHg(SCN) 4: Influence of the magnetic breakdown on evaluation of the effective mass and the scattering time

    Science.gov (United States)

    Sasaki, T.; Biberacher, W.; Fukase, T.

    1998-05-01

    The change of the de Haas-van Alphen (dHvA) oscillation between the low-field spin-density-wave (SDW) phase and the high-field ( H⩾23 T) metallic phase of the organic conductor α-(BEDT-TTF) 2KHg(SCN) 4 is explained in terms of a model of the magnetic breakdown (MB) and a reconstructed Fermi surface by SDW. On the reconstructed Fermi surface, the scattering time obtained by fitting the standard Lifshitz-Kosevich formulation to the dHvA oscillations is affected by the MB giving the additional field-dependent effect. Furthermore, the evaluation of the effective mass needs to consider the additional temperature-dependent factor being due to the MB gap which may change intrinsically and/or thermally with temperature.

  9. High field magnetotransport and point contact Andreev reflection measurements on CuCr{sub 2}Se{sub 4} and CuCr{sub 2}Se{sub 3}Br—Degenerate magnetic semiconductor single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Borisov, K., E-mail: borisovk@tcd.ie; Coey, J. M. D.; Stamenov, P. [School of Physics and CRANN, Trinity College, Dublin 2 (Ireland); Alaria, J. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom)

    2014-05-07

    Single crystals of the metallically degenerate fully magnetic semiconductors CuCr{sub 2}Se{sub 4} and CuCr{sub 2}Se{sub 3}Br have been prepared by the Chemical Vapour Transport method, using either Se or Br as transport agents. The high-quality, millimetre-sized, octahedrally faceted, needle- and platelet-shaped crystals are characterised by means of high field magnetotransport (μ{sub 0}H≤ 14 T) and Point Contact Andreev Reflection. The relatively high spin polarisation observed |P|>0.56, together with the relatively low minority carrier effective mass of 0.25 m{sub e}, and long scattering time  10{sup −13} s, could poise these materials for integration in low- and close-to-room temperature minority injection bipolar heterojunction transistor demonstrations.

  10. Magnetic study of iron sorbitol

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro, F.J. E-mail: osoro@posta.unizar.es; Larrea, A.; Abadia, A.R.; Romero, M.S

    2002-09-01

    A magnetic study of iron sorbitol, an iron-containing drug to treat the iron deficiency anemia is presented. Transmission electron microscopy reveals that the system contains nanometric particles with an average diameter of 3 nm whose composition is close to two-line ferrihydrite. The characterisation by magnetisation and AC susceptibility measurements indicates superparamagnetic behaviour with progressive magnetic blocking starting at 8 K. The quantitative analysis of the magnetic results indicates that the system consists of an assembly of very small magnetic moments, presumably originated by spin uncompensation of the antiferromagnetic nanoparticles, with Arrhenius type magnetic dynamics.

  11. SMARTer for magnetic structure studies

    Indian Academy of Sciences (India)

    E G R Putra; A Ikram; J Kohlbrecher

    2008-11-01

    SMARTer, a 36-meter small angle neutron scattering (SANS) spectrometer was installed at the Neutron Scattering Laboratory (NSL), National Nuclear Energy Agency of Indonesia – BATAN in Serpong, Indonesia and has performed the experiment for studying the magnetic structures of Cu(NiFe), CuCo and FeSiBNbCu metal alloys. The experiments were conducted at room temperature and up to 1 T (10 kOe) of external magnetic field. At zero fields, isotropic scattering identified as nuclear scattering is dominant. When a magnetic field is applied in a horizontal direction perpendicular to the neutron beam, the response of the magnetic scattering permits extraction of the field-induced re-arrangement of the magnetic moment. With increasing field the distortion is more pronounced and the magnetic scattering dominates the intensity and affects the peak position. Radial and angular averaging from experimental data are given to show the details of magnetic structures.

  12. Lumbar Modic Changes - A Comparison Between Findings at Low-and High-field MRI

    DEFF Research Database (Denmark)

    Bendix, Tom; Sorensen, Joan S; Henriksson, Gustaf A C

    2012-01-01

    Study Design. A cross-sectional observational study.Objective. To investigate if there is a difference in findings of lumbar Modic changes in low-field (0.3 Tesla) magnetic resonance imaging (MRI) as compared to high field (1.5 Tesla).Summary of Background Data. It is a challenge to give patients...

  13. High-field proton MRS of human brain

    Energy Technology Data Exchange (ETDEWEB)

    Di Costanzo, Alfonso E-mail: alfonso.dicostanzo@unina2.it; Trojsi, F.; Tosetti, M.; Giannatempo, G.M.; Nemore, F.; Piccirillo, M.; Bonavita, S.; Tedeschi, G.; Scarabino, T

    2003-11-01

    Proton magnetic resonance spectroscopy ({sup 1}H-MRS) of the brain reveals specific biochemical information about cerebral metabolites, which may support clinical diagnoses and enhance the understanding of neurological disorders. The advantages of performing {sup 1}H-MRS at higher field strengths include better signal to noise ratio (SNR) and increased spectral, spatial and temporal resolution, allowing the acquisition of high quality, easily quantifiable spectra in acceptable imaging times. In addition to improved measurement precision of N-acetylaspartate, choline, creatine and myo-inositol, high-field systems allow the high-resolution measurement of other metabolites, such as glutamate, glutamine, {gamma}-aminobutyric acid, scyllo-inositol, aspartate, taurine, N-acetylaspartylglutamate, glucose and branched amino acids, thus extending the range of metabolic information. However, these advantages may be hampered by intrinsic field-dependent technical difficulties, such as decreased T2 signal, chemical shift dispersion errors, J-modulation anomalies, increased magnetic susceptibility, eddy current artifacts, limitations in the design of homogeneous and sensitive radiofrequency (RF) coils, magnetic field instability and safety issues. Several studies demonstrated that these limitations could be overcome, suggesting that the appropriate optimization of high-field {sup 1}H-MRS would expand the application in the fields of clinical research and diagnostic routine.

  14. High-field Faraday rotation in II-VI-based semimagnetic semiconductors

    NARCIS (Netherlands)

    Savchuk, AI; Fediv, [No Value; Nikitin, PI; Perrone, A; Tatzenko, OM; Platonov, VV

    1998-01-01

    The effects of d-d exchange interaction have been studied by measuring high-field Faraday rotation in II-VI-based semimagnetic semiconductors. For Cd1-xMnxTe crystals with x = 0.43 and at room temperature a saturation in magnetic field dependence of the Faraday rotation has been observed. In the cas

  15. Nonlinear Optimization of CLIC DRS New Design with Variable Bends and High Field Wigglers

    CERN Document Server

    Ghasem, H.; Alabau-Gonzalvo, J.; Papadopoulou, S.; Papaphilippou, Y.

    2016-01-01

    The new design of CLIC damping rings is based on longitudinal variable bends and high field superconducting wiggler magnets. It provides an ultra-low horizontal normalised emittance of 412 nm-rad at 2.86 GeV. In this paper, nonlinear beam dynamics of the new design of the damping ring (DR) with trapezium field profile bending magnets have been investigated in detail. Effects of the misalignment errors have been studied in the closed orbit and dynamic aperture.

  16. Antenna development for high field plasma imaging.

    Science.gov (United States)

    Kong, X; Domier, C W; Luhmann, N C

    2010-10-01

    Electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) are two microwave nonperturbing plasma visualization techniques that employ millimeter-wave imaging arrays with lens-coupled planar antennas, yielding time-resolved images of temperature (via ECEI) and electron density (via MIR) fluctuations within high temperature magnetic fusion plasmas. A series of new planar antennas have been developed that extend this technology to frequencies as high as 220 GHz for use on high field plasma devices with toroidal fields in excess of 3 T. Antenna designs are presented together with theoretical calculations, simulations, and experimental measurements.

  17. Study of axial magnetic effect

    Energy Technology Data Exchange (ETDEWEB)

    Braguta, Victor [IHEP, Protvino, Moscow region, 142284 Russia ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 (Russian Federation); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Chernodub, M. N. [CNRS, Laboratoire de Mathématiques et Physique Théorique, Université François-Rabelais Tours, Fédération Denis Poisson, Parc de Grandmont, 37200 Tours, France Department of Physics and Astronomy, University of Gent, Krijgslaan 281, S9, B-9000 Gent (Belgium); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Goy, V. A. [School of Natural Sciences, Far Eastern Federal University, Sukhanova street 8, Vladivostok, 690950 (Russian Federation); Landsteiner, K. [Instituto de Física Teórica UAM/CSIC, C/ Nicolás Cabrera 13-15, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Molochkov, A. V. [School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Ulybyshev, M. [ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 Russia Institute for Theoretical Problems of Microphysics, Moscow State University, Moscow, 119899 (Russian Federation)

    2016-01-22

    The Axial Magnetic Effect manifests itself as an equilibrium energy flow of massless fermions induced by the axial (chiral) magnetic field. Here we study the Axial Magnetic Effect in the quenched SU(2) lattice gauge theory with massless overlap fermions at finite temperature. We numerically observe that in the low-temperature hadron phase the effect is absent due to the quark confinement. In the high-temperature deconfinement phase the energy flow is an increasing function of the temperature which reaches the predicted asymptotic T{sup 2} behavior at high temperatures. We find, however, that energy flow is about one order of magnitude lower compared to a theoretical prediction.

  18. Study on Soil Magnetic Effect

    Institute of Scientific and Technical Information of China (English)

    YIYAN-LI; LIUXIAO-YI

    1995-01-01

    A study on the effect of applied magnetic field was performed with six types of soils collected from northeastern China.Magnetic field was found to cause changes of soil physico-chemical properties and soil enzyme activities.An appropriate applied magnetic field could cut down soil zeta-potential,soil specific surface,soil water potential and soil swelling capacity;raise the charge density on soil colloids and the activities of invertase,hydrogen peroxidase and amylase in the soils;enhance soil aggregation and improve soil structural status and soil water-releasing capability.

  19. Trace level impurity method development with high-field asymmetric waveform ion mobility spectrometry: systematic study of factors affecting the performance.

    Science.gov (United States)

    Champarnaud, Elodie; Laures, Alice M-F; Borman, Phil J; Chatfield, Marion J; Kapron, James T; Harrison, Mark; Wolff, Jean-Claude

    2009-01-01

    For the determination of trace level impurities, analytical chemists are confronted with complex mixtures and difficult separations. New technologies such as high-field asymmetric waveform ion mobility spectrometry (FAIMS) have been developed to make their work easier; however, efficient method development and troubleshooting can be quite challenging if little prior knowledge of the factors or their settings is available. We present the results of an investigation performed in order to obtain a better understanding of the FAIMS technology. The influence of eight factors (polarity of dispersion voltage, outer bias voltage, total gas flow rate, composition of the carrier gas (e.g. %He), outer electrode temperature, ratio between the temperatures of the inner and outer electrodes, flow rate and composition of the make-up mobile phase) was assessed. Five types of responses were monitored: value of the compensation voltage (CV), intensity, width and asymmetry of the compensation voltage peak, and resolution between two peaks. Three types of studies were performed using different test mixtures and various ionisation modes to assess whether the same conclusions could be drawn across these conditions for a number of different types of compounds. To extract the maximum information from as few experiments as possible, a Design of Experiment (DoE) approach was used. The results presented in this work provide detailed information on the factors affecting FAIMS separations and therefore should enable the user to troubleshoot more effectively and to develop efficient methods.

  20. High field 27Al MAS NMR and TPD studies of active sites in ethanol dehydration using thermally treated transitional aluminas as catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jian Zhi; Xu, Suochang; Kwak, Ja Hun; Hu, Mary Y.; Wan, Chuan; Zhao, Zhenchao; Szanyi, Janos; Bao, Xinhe; Han, Xiuwen; Wang, Yong; Peden, Charles H. F.

    2016-04-01

    High field quantitative 27Al MAS NMR and temperature programmed desorption (TPD) of ethanol are used to study the surface and phase transformation of gamma-Al2O3 during calcination in the temperature range of 500 to 1300 degrees C. Following ethanol adsorption, ethylene is generated during TPD with a desorption temperature > 200 degrees C. With increasing calcination temperature prior to TPD, the amount of ethylene produced decreases monotonically. Significantly, 27Al MAS NMR reveals that the amount of penta-coordinate Al3+ ions (Lewis acid sites) also decreases with increasing calcination temperature. In fact, a strong correlation between the amount of penta-coordinate Al3+ ions and the amount of strongly adsorbed ethanol molecules (i.e., the ones that convert to ethylene during TPD) is obtained. This result indicates that the penta-coordinate aluminum sites are the catalytic active sites on alumina surfaces during ethanol dehydration reaction across the entire course of gamma- to alpha-Al2O3 phase transformations.

  1. Design Study Of Cyclotron Magnet With Permanent Magnet

    Science.gov (United States)

    Kim, Hyun Wook; Chai, Jong Seo

    2011-06-01

    Low energy cyclotrons for Positron emission tomography (PET) have been wanted for the production of radio-isotopes after 2002. In the low energy cyclotron magnet design, increase of magnetic field between the poles is needed to make a smaller size of magnet and decrease power consumption. The Permanent magnet can support this work without additional electric power consumption in the cyclotron. In this paper the study of cyclotron magnet design using permanent magnet is shown and also the comparison between normal magnet and the magnet which is designed with permanent magnet is shown. Maximum energy of proton is 8 MeV and RF frequency is 79.3 MHz. 3D CAD design was done by CATIA P3 V5 R18 [1] and the All field calculations had been performed by OPERA-3D TOSCA [2]. The self-made beam dynamics program OPTICY [3] is used for making isochronous field and other calculations.

  2. The Project for the New High Field Facility

    OpenAIRE

    Motokawa, M.

    1996-01-01

    Since High Field Laboratory for Superconducting Materials attached to Institute for Materials Research of Tohoku University started, 15 years has passed. We have had plenty of fruitful scientific and technological results not only in a field of superconductivity but also in areas of magnetism, semiconductors, organic conductors, chemical and biological materials and crystallography. The equipments in the Laboratory, however, are now getting aged and the available high field of 31 T obtained b...

  3. T1 and susceptibility contrast at high fields

    Science.gov (United States)

    Neelavalli, Jaladhar

    Clinical imaging at high magnetic field strengths (≥ 3Tesla) is sought after primarily due to the increased signal strength available at these fields. This increased SNR can be used to perform: (a) high resolution imaging in the same time as at lower field strengths; (b) the same resolution imaging with much faster acquisition; and (c) functional MR imaging (fMRI), dynamic perfusion and diffusion imaging with increased sensitivity. However they are also associated with increased power deposition (SAR) due to increase in imaging frequency and longer T1 relaxation times. Longer T1s mean longer imaging times for generating good T1 contrast images. On the other hand for faster imaging, at high fields fast spin echo or magnetization prepared sequences are conventionally proposed which are, however, associated with high SAR values. Imaging with low SAR is more and more important as we move towards high fields and particularly for patients with metallic implants like pacemakers or deep brain stimulator. The SAR limit acceptable for these patients is much less than the limit acceptable for normal subjects. A new method is proposed for imaging at high fields with good contrast with simultaneous reduction in power deposition. Further, T1 based contrast optimization problem in FLASH imaging is considered for tissues with different T1s but same spin densities. The solution providing optimal imaging parameters is simplified for quick and easy computation in a clinical setting. The efficacy of the simplification is evaluated and practical limits under which the simplification can be applied are worked out. The phase difference due to variation in magnetic susceptibility property among biological tissues is another unique source of contrast which is different from the conventional T1, T2 and T2* contrast. This susceptibility based phase contrast has become more and more important at high fields, partly due to contrast generation issues due to longer T 1s and shorter T2s and

  4. Experimental studies of magnetic perovskites

    Science.gov (United States)

    Golovanov, Vladimir Valentinovich

    1998-11-01

    The present work addresses the phenomenon of Giant Magnetoresistance (GMR) and the role of Jahn-Teller distortion in the conduction mechanism of GMR materials. For this purpose, GMR and related perovskites are studied experimentally using infrared reflection spectroscopy, synchrotron x-ray diffraction, and electrical transport measurements. Reflectivity and x-ray diffraction studies of a vacancy doped rhombohedrally distorted GMR material, La0.936Mn0.982O3, indicate the presence of dynamic Jahn-Teller distortion above the magnetic ordering temperature (Tc = 225K) and a substantial reduction of the distortion below Tc. In particular, above Tc, the optical conductivity of large single crystals of the material shows the broad peak around 10,000 cm-1, which shifts towards zero frequency as the ferromagnetic state develops. The peak is attributed to the Jahn-Teller splitting of the two-fold degenerate eg level. Powder x-ray diffraction measurements performed on the same material reveal a sharp 3% reduction of the rhombohedral distortion at the magnetic ordering temperature. This reduction reflects the decrease in the magnitude of the dynamic Jahn-Teller distortion at the magnetic ordering. The transport and magnetic measurements on non Jahn-Teller active La1-xSrxCoO3 perovskites show much lower magnetoresistance, compatible with the conventional double-exchange theory. The relatively high values of magnetoresistance for low doped (x ≤ 0.15) compounds at low temperatures are also interpreted in terms of the double-exchange model.

  5. SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ellens, N [Johns Hopkins University, Baltimore, Maryland (United States); Farahani, K [National Cancer Institute, Bethesda, MD (United States)

    2015-06-15

    Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many

  6. Study of marine magnetic field

    Digital Repository Service at National Institute of Oceanography (India)

    Bhattacharya, G.C.

    (COB) is again both a basic scientific requirement as well at some places is a requirement under the UNCLOS related Legal Continental Shelf demarcation purpose. In the oceanic areas, the marine magnetic studies are one of the essential tools... oceans increased, more and more deviations from this simplified model, such as propagating ridges and overlapping spreading centers were discovered. These observations enabled the study of new aspects of seafloor spreading process beyond the initial...

  7. HTS Insert Magnet Design Study

    CERN Document Server

    Devaux, M; Fleiter, J; Fazilleau, P; Lécrevisse, T; Pes, C; Rey, J-M; Rifflet, J-M; Sorbi, M; Stenvall, A; Tixador, P; Volpini, G

    2011-01-01

    Future accelerator magnets will need to reach higher field in the range of 20 T. This field level is very difficult to reach using only Low Temperature Superconductor materials whereas High Temperature Superconductors (HTS) provide interesting opportunities. High current densities and stress levels are needed to design such magnets. YBCO superconductor indeed carries large current densities under high magnetic field and provides good mechanical properties especially when produced using the IBAD approach. The HFM EUCARD program studies the design and the realization of an HTS insert of 6 T inside a Nb3Sn dipole of 13T at 4.2 K. In the2HTS insert, engineering current densities higher than 250 MA/m under 19 T are required to fulfill the specifications. The stress level is also very severe. YBCO IBAD tapes theoretically meet these challenges from presented measurements. The insert protection is also a critical because HTS materials show low quench propagation velocities and the coupling with the Nb3Sn magnet make...

  8. Study on healthcare magnetic concrete

    Institute of Scientific and Technical Information of China (English)

    YANG Yushan; DONG Faqin; FENG Jianjun

    2006-01-01

    Magnetic concrete was prepared by adding SrFe12O9 magnetic functional elementary material into concrete, and its magnetism was charged by magnetizing machine. The effect of SrFe12O9 content on magnetic field intensity and the attenuation of magnetic field intensity were investigated in different medium. The blood viscosity of rats kept in magnetic concrete was carried out. The results show that magnetic concrete can be prepared by adding SrFe12O9, and magnetic fields intensity increases with the augment of ferrite content. The attenuation of magnetic fields is mainly related with the density of medium, but it is secondary to the properties of medium. The blood viscosity of rats decreases under magnetic condition, but the blood cells remain the same as before. Experimental results support that magnetic concrete has great healthcare function.

  9. High-resolution T{sub 2}-weighted cervical cancer imaging: a feasibility study on ultra-high-field 7.0-T MRI with an endorectal monopole antenna

    Energy Technology Data Exchange (ETDEWEB)

    Hoogendam, Jacob P.; Verheijen, Rene H.M.; Zweemer, Ronald P. [University Medical Centre Utrecht, Department of Gynaecological Oncology, UMC Utrecht Cancer Centre, PO Box 85500, Utrecht (Netherlands); Kalleveen, Irene M.L.; Castro, Catalina S.A. de; Raaijmakers, Alexander J.E.; Bosch, Maurice A.A.J. van den; Klomp, Dennis W.J.; Veldhuis, Wouter B. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands)

    2017-03-15

    We studied the feasibility of high-resolution T{sub 2}-weighted cervical cancer imaging on an ultra-high-field 7.0-T magnetic resonance imaging (MRI) system using an endorectal antenna of 4.7-mm thickness. A feasibility study on 20 stage IB1-IIB cervical cancer patients was conducted. All underwent pre-treatment 1.5-T MRI. At 7.0-T MRI, an external transmit/receive array with seven dipole antennae and a single endorectal monopole receive antenna were used. Discomfort levels were assessed. Following individualised phase-based B{sub 1} {sup +} shimming, T{sub 2}-weighted turbo spin echo sequences were completed. Patients had stage IB1 (n = 9), IB2 (n = 4), IIA1 (n = 1) or IIB (n = 6) cervical cancer. Discomfort (ten-point scale) was minimal at placement and removal of the endorectal antenna with a median score of 1 (range, 0-5) and 0 (range, 0-2) respectively. Its use did not result in adverse events or pre-term session discontinuation. To demonstrate feasibility, T{sub 2}-weighted acquisitions from 7.0-T MRI are presented in comparison to 1.5-T MRI. Artefacts on 7.0-T MRI were due to motion, locally destructive B{sub 1} interference, excessive B{sub 1} under the external antennae and SENSE reconstruction. High-resolution T{sub 2}-weighted 7.0-T MRI of stage IB1-IIB cervical cancer is feasible. The addition of an endorectal antenna is well tolerated by patients. (orig.)

  10. Environmental magnetic studies of lacustrine sediments

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    In recent decades, environmental magnetism has become an important method for studying past global climatic and environmental changes. For an environmental magnetic study, it is important to understand the magnetic properties, of various magnetic minerals in lacustrine sedimcuts and the processes involved in the formation, transport,and preservation of these magnetic minerals. The magnetic response of lacustrine sediments to climatic change may vary widely from lake to lake. To reconstruct the processes contributing to paleoclimatic and paleoenvironmental change, it is, therefore, necessary to derive a complete understanding of the potential origin of the magnetic signal observed.

  11. High field – low energy muon ionization cooling channel

    Directory of Open Access Journals (Sweden)

    Hisham Kamal Sayed

    2015-09-01

    Full Text Available Muon beams are generated with large transverse and longitudinal emittances. In order to achieve the low emittances required by a muon collider, within the short lifetime of the muons, ionization cooling is required. Cooling schemes have been developed to reduce the muon beam 6D emittances to ≈300  μm-rad in transverse and ≈1–1.5  mm in longitudinal dimensions. The transverse emittance has to be further reduced to ≈50–25  μm-rad with an upper limit on the longitudinal emittance of ≈76  mm in order to meet the high-energy muon collider luminosity requirements. Earlier studies of the transverse cooling of low energy muon beams in high field magnets showed a promising performance, but did not include transverse or longitudinal matching between the stages. In this study we present the first complete design of the high field-low energy ionization cooling channel with transverse and longitudinal matching. The channel design was based on strong focusing solenoids with fields of 25–30 T and low momentum muon beam starting at 135  MeV/c and gradually decreasing. The cooling channel design presented here is the first to reach ≈50 micron scale emittance beam. We present the channel’s optimized design parameters including the focusing solenoid fields, absorber parameters and the transverse and longitudinal matching.

  12. XPS Studies of Magnetic Multilayers

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    NiOx/Ni81Fe19 and Co/AlOx/Co magnetic multilayers were fabri cated by reactive RF/DC magnetron sputtering on clean glass substrates and oxidized Si (100) substrates, respectively. The exchange biasing field (Hex) between NiOx and Ni81Fe19 as a function of oxidation stat es was studied by X-ray photoelectron spectroscopy (XPS). The oxidatio n states and the oxide thickness of Al layers in magnetic multilayer f ilms consisting of Co/AlOx/Co were also analyzed. It is found that the Hex of NiOx/Ni81Fe19 films only depends on Ni2+ but not on Ni3+ or Ni . The bottom Co can be completely covered by depositing an Al layer th icker than 2.0nm. The oxide layer was Al2O3, and its thickness was 1.1 5nm.

  13. Preliminary study of superconducting bulk magnets for Maglev

    Science.gov (United States)

    Fujimoto, Hiroyuki; Kamijo, Hiroki

    Recent development shows that melt-processed YBaCuO (Y123) or Rare Earth (RE)123 superconductors have a high Jc at 77 K and high magnetic field, leading to high field application as a superconducting quasi-permanent bulk magnet with the liquid nitrogen refrigeration. One of the promising applications is a superconducting magnet for the magnetically levitated (Maglev) train. We discuss a superconducting bulk magnet for the Maglev train in the aspect of a preliminary design of the bulk magnet and also processing for (L)REBaCuO bulk superconductors and their characteristic superconducting properties.

  14. High magnetic field studies of BEDT-TTF organic conductors

    Energy Technology Data Exchange (ETDEWEB)

    Honold, M.M

    1999-07-01

    This Thesis gives a detailed account of the high magnetic field properties of {alpha}-phase BEDT-TTF charge-transfer salts, with particular focus on the salts {alpha}-(BEDT-TTF){sub 2}KHg(SCN){sub 4} and {alpha}-(BEDT-TTF){sub 2}TlHg(SCN){sub 4}. The existence of the bulk quantum Hall effect and its eventual destruction in the high-field limit is shown by a variety of experimental means, including magnetoresistance, magnetisation and Hall potential oscillation studies; the latter are based on a new technique specifically developed for this purpose. Chapter 1 introduces the concept of organic conductors and emphasises their potential as prototype systems of reduced dimensionality; in Chapter 2, the necessary physics and experimental techniques for their investigation are outlined. Following model calculations which suggested the possibility of the quantum Hall effect in {alpha}-phase BEDT-TTF salts, measurements of the Hall resistivity were carried out on {alpha}-(BEDT-TTF){sub 2}TlHg(SCN){sub 4} (described in Chapter 3). These exhibit a series of plateaux and represent the direct observation of the quantum Hall effect in a bulk material. Chapter 4 reports the discovery of an anomalous magnetotransport mode in the interplane resistance of {alpha}-(BEDT-TTF){sub 2}KHg(SCN){sub 4} which involves the suppression and phase inversion of the Shubnikov-de Haas oscillations at low temperatures. This is interpreted as the action of a two-dimensional chiral Fermi liquid formed from the current-carrying edge states of each quantum Hall layer. Chapter 5 reports the first observation of magnetic breakdown in the high-field phase of {alpha}-(BEDT-TTF){sub 2}KHg(SCN){sub 4}, allowing an improved description of the high-field Fermi surface topology. These results are used to develop a new model for the nested low-field Fermi surface which can explain experimental evidence previously unaccounted for. Studies of the limiting behaviour of Hall potential oscillations in Chapter 6 show

  15. High Field X-ray Diffraction Study for Ni46.4Mn38.8In12.8Co2.0 Metamagnetic Shape Memory Film

    Directory of Open Access Journals (Sweden)

    Yoshifuru Mitsui

    2017-09-01

    Full Text Available The transformation behaviors on metamagnetic shape memory Ni46.4Mn38.8In12.8Co2.0 film were investigated by X-ray diffraction experiments in the temperature up to 473 K and magnetic fields µ0H up to 5 T. The prepared film showed the parent phase with L21 structure at 473 K, and with preferred orientation along the 111 plane. The magnetic field induced reverse transformation was directly observed at T = 366 K, which was just around the reverse transformation starting temperature.

  16. High field 27Al MAS NMR and TPD studies of active sites in ethanol dehydration using thermally treated transitional aluminas as catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jian Zhi; Xu, Suochang; Kwak, Ja Hun; Hu, Mary Y.; Wan, Chuan; Zhao, Zhenchao; Szanyi, Janos; Bao, Xinhe; Han, Xiuwen; Wang, Yong; Peden, Charles H. F.

    2016-04-01

    Gamma-, sigma- and theta-Al2O3 are well known metastable “transitional” alumina structural polymorphs. Upon heating, Al2O3 transitions to the so-called and Al2O3 polymorphs and finally forms the thermally stable Al2O3. The poorly developed crystallinity and co-existence of the , , and Al2O3 prior to forming all Al2O3, making it difficult to characterize the structures as well as to quantify the various phases of the transition alumina. As a result, there are significant controversies in the literatures. In this work, a detailed NMR analysis was carried out at high magnetic field on three special aluminum oxide samples where the, , , Al2O3 phases are made dominant, respectively, by controlling the synthesis conditions. The goal is to simplify, including making unambiguous, spectral assignments in 27Al MAS NMR spectra of transition alumina that have not yet been commonly agreed previously. Specifically, quantitative 1D 27Al MAS NMR was used to quantify the ratios of the different alumina structural units, 2D MQMAS 27Al MAS was used for obtaining the highest spectral resolution to guide the analysis of the 1D spectrum, and a saturation pulse sequence was integrated into the 1D NMR to select the amorphous structures, including obtain spectra where the penta-coordinate sites are observed with enhanced relative intensity. Collectively, this study uniquely assigns Al-peaks (both octahedral and tetrahedral) to the Al2O3 and the Al2O3 phases and offers a new way of understanding, including quantifying, the different structural units and sites in transition alumina samples.

  17. Study of Magnetic Domain Dynamics Using Nonlinear Magnetic Responses: Magnetic Diagnostics of the Itinerant Magnet MnP

    Science.gov (United States)

    Mito, Masaki; Matsui, Hideaki; Tsuruta, Kazuki; Deguchi, Hiroyuki; Kishine, Jun-ichiro; Inoue, Katsuya; Kousaka, Yusuke; Yano, Shin-ichiro; Nakao, Yuya; Akimitsu, Jun

    2015-10-01

    The nonlinear and linear magnetic responses to an ac magnetic field H are useful for the study of the magnetic dynamics of both magnetic domains and their constituent spins. In particular, the third-harmonic magnetic response M3ω reflects the dynamics of magnetic domains. Furthermore, by considering the ac magnetic response as a function of H, we can evaluate the degree of magnetic nonlinearity, which is closely related to M3ω. In this study, a series of approaches was used to examine the itinerant magnet MnP, in which both ferromagnetic and helical phases are present. On the basis of this investigation, we systematize the diagnostic approach to evaluating nonlinearity in magnetic responses.

  18. High field superconductor development and understanding

    Energy Technology Data Exchange (ETDEWEB)

    Larbalestier, David C. [Florida State Univ., Tallahassee, FL (United States); Lee, Peter J. [Florida State Univ., Tallahassee, FL (United States); Tarantini, Chiara [Florida State Univ., Tallahassee, FL (United States)

    2014-09-28

    All present circular accelerators use superconducting magnets to bend and to focus the particle beams. The most powerful of these machines is the large hadron collider (LHC) at CERN. The main ring dipole magnets of the LHC are made from Nb-Ti but, as the machine is upgraded to higher luminosity, more powerful magnets made of Nb3Sn will be required. Our work addresses how to make the Nb3Sn conductors more effective and more suitable for use in the LHC. The most important property of the superconducting conductor used for an accelerator magnet is that it must have very high critical current density, the property that allows the generation of high magnetic fields in small spaces. Nb3Sn is the original high field superconductor, the material which was discovered in 1960 to allow a high current density in the field of about 9 T. For the high luminosity upgrade of the LHC, much higher current densities in fields of about 12 Tesla will be required. The critical value of the current density is of order 2600 A/mm2 in a field of 12 Tesla. But there are very important secondary factors that complicate the attainment of this critical current density. The first is that the effective filament diameter must be no larger than about 40 µm. The second factor is that 50% of the cross-section of the Nb3Sn conductor that is pure copper must be protected from any poisoning by any Sn leakage through the diffusion barrier that protects the package of niobium and tin from which the Nb3Sn is formed by a high temperature reaction. These three, somewhat conflicting requirements, mean that optimization of the conductor is complex. The work described in this contract report addresses these conflicting requirements. They show that very sophisticated characterizations can uncover the way to satisfy all 3 requirements and they also suggest that the ultimate optimization of Nb3Sn is still not yet in sight

  19. Study on magnetic gene transfer using HTS bulk magnet

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Kota, E-mail: nakagawa@qb.see.eng.osaka-u.ac.jp [Graduate School of Engineering, Osaka University, Yamadaoka 2-1, Suita, Osaka 565-0871 (Japan); Ohaku, Yoshihiro; Tamada, Junya; Mishima, Fumihito; Akiyama, Yoko [Graduate School of Engineering, Osaka University, Yamadaoka 2-1, Suita, Osaka 565-0871 (Japan); Osako, Mariana Kiomy; Nakagami, Hironori [Graduate School of Medicine, Osaka University, Yamadaoka 2-1, Suita, Osaka 565-0871 (Japan); Nishijima, Shigehiro [Graduate School of Engineering, Osaka University, Yamadaoka 2-1, Suita, Osaka 565-0871 (Japan)

    2013-11-15

    Highlights: •DNA–magnetite complexes were prepared as ferromagnetic DNA carrier. •The condition of magnetic field to suppress the diffusion was found by calculation. •The result of model experiment showed the validity of the calculated value. •The results of in vivo experiments showed that the amount of gene expression was significantly increased by magnetic field. -- Abstract: This study aimed to realize local and high-efficient gene expression by suppressing the diffusion of ferromagnetic DNA carriers in a strong magnetic field generated by HTS bulk magnet. DNA–magnetite complexes were prepared as ferromagnetic DNA carrier and the magnetic gene transfer using the DNA carriers was examined. From the results of the simulation and the model experiment, it was shown that the particle diffusion was suppressed within 10 mm in diameter by the magnetic field at 20 mm above the HTS bulk magnet. The results of in vivo experiments showed that the amount of gene expression was significantly increased by magnetic field.

  20. Study on Compound Effect of Bonded Magnets

    Institute of Scientific and Technical Information of China (English)

    Chang Ying; Ma Nuo; Yu xiaojun; Li Wei; Liu Changsheng; Lian Fazeng

    2004-01-01

    The compound effect of Nd2Fe14B/Fe3B-Ferrite bonded magnets was studied.The result shows that the value ofβjHC obviously decreases with the ferrite content increasing.In addition, a functional relation between magnetic properties and ferrite content was clearly revealed by the physical relation in the magnetic powders.

  1. First observation of trapped high-field seeking ultracold neutron spin states

    Energy Technology Data Exchange (ETDEWEB)

    Daum, M., E-mail: manfred.daum@psi.ch [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Department of Physics, University of Virginia, Charlottesville, VA 22904-4714 (United States); Fierlinger, P. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Franke, B. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Geltenbort, P. [ILL, Institut Laue-Langevin, Grenoble (France); Goeltl, L. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Gutsmiedl, E. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Karch, J. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Kessler, G. [TUM, Physik-Department Technische Universitaet Muenchen, Excellence Cluster Universe, Munich (Germany); Kirch, K. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); IPP, Institut f. Teilchenphysik, ETH Zuerich, CH-8093 Zuerich (Switzerland); Koch, H.-C.; Kraft, A.; Lauer, T. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Lauss, B. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Pierre, E. [LPC, Laboratoire de Physique Corpusculaire, ENSICAEN-CNRS/IN2P3, Caen (France); Pignol, G. [LPSC, Laboratoire de Physique Subatomique et de Cosmologie, UJF-CNRS/IN2P3-INPG, Grenoble (France); Reggiani, D.; Schmidt-Wellenburg, P. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland); Sobolev, Yu.; Zechlau, T. [Institut fuer Physik, Johannes-Gutenberg-Universitaet, Mainz (Germany); Zsigmond, G. [PSI, Paul-Scherrer-Institut, CH-5232 Villigen PSI (Switzerland)

    2011-10-25

    Ultracold neutrons were stored in a volume, using a magnetic dipole field shutter. Radial confinement was provided by material walls. Low-field seeking neutrons were axially confined above the magnetic field. High-field seeking neutrons are trapped inside the magnetic field. They can systematically shift the measured neutron lifetime to lower values in experiments with magnetic confinement.

  2. In-depth magnetic characterization of a [2 × 2] Mn(III) square grid using SQUID magnetometry, inelastic neutron scattering, and high-field electron paramagnetic resonance spectroscopy

    DEFF Research Database (Denmark)

    Konstantatos, Andreas; Bewley, Robert; Barra, Anne Laure

    2016-01-01

    A tetranuclear [2 × 2] grid-like manganese(III) Schiff base complex, Mn4, has been synthesized and characterized by single-crystal X-ray crystallography. Direct-current magnetization measurements were performed on the system and proved to be insufficient for an accurate magnetic model to be deduc...

  3. HIGH FIELD Q-SLOPE AND THE BAKING EFFECT

    Energy Technology Data Exchange (ETDEWEB)

    Ciovati, Gianluigi [JLAB

    2009-11-01

    The performance of SRF cavities made of bulk Nb at high fields (peak surface magnetic field greater than about 90 mT) is characterized by exponentially increasing RF losses (high-field Q-slope), in the absence of field emission, which are often mitigated by a low temperature (100-140 °C, 12-48h) baking. In this contribution, recent experimental results and phenomenological models to explain this effect will be briefly reviewed. New experimental results on the high-field Q-slope will be presented for cavities that had been heat treated at high temperature in the presence of a small partial pressure of nitrogen. Improvement of the cavity performances have been obtained, while surface analysis measurements on Nb samples treated with the cavities revealed significantly lower hydrogen concentration than for samples that followed standard cavity treatments.

  4. Magnetic stripping studies for SPL

    CERN Document Server

    Posocco, P; CERN. Geneva. BE Department

    2010-01-01

    Magnetic stripping of H- can seriously enhance the beam losses along the SPL machine. These losses depend on the beam energy, on the beam transverse distribution and on the intensity of the magnetic field. For radioprotection issues the losses must be limited to 1 W/m. In this paper we will concentrate on the stripping phenomena inside the quadrupole magnets with the aim of defining the quadrupole range for the design phase of SPL.

  5. Spontaneous Radiation Emission from Short, High Field Strength Insertion Devices

    Energy Technology Data Exchange (ETDEWEB)

    Geoffrey Krafft

    2005-09-15

    Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the radiation spectrum for short, high-field insertion devices. It is used to calculate the emission from some insertion device designs of recent interest.

  6. Orthodontic brackets in high field MR imaging: experimental evaluation of magnetic field interactions at 3.0 tesla; Kieferorthopaedische Brackets in der Hochfeld-Magnetresonanz-Tomographie: Experimentelle Beurteilung magnetischer Anziehungs- und Rotationskraefte bei 3 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Eppendorf, Hamburg (Germany); Klocke, A.; Kahl-Nieke, B. [Poliklinik fuer Kieferorthopaedie, Universitaetsklinikum Eppendorf, Hamburg (Germany)

    2005-12-15

    Purpose: To evaluate static magnetic field interactions for 32 commonly used orthodontic brackets in a 3.0 T magnetic resonance imaging (MRI) system. Materials and methods: 32 orthodontic brackets consisting of a steel alloy (n=27), a cobalt-chromium alloy (n=2), ceramic (n=1), ceramic with a steel slot (n=1), and titanium (n=1) from 13 different manufacturers were tested for magnetic field interactions in a static magnetic field at 3.0 T (Gyroscan Intera 3.0 T, Philips Medical Systems, Best, Netherlands). The magnetic deflection force F{sub Z} [mN] was evaluated by determining the deflection angle {beta}[ ] using the established deflection angle test according to the ASTM guidelines. The magnetic-field-induced rotational force F{sub rot} or torque was qualitatively determined using a 5-point grading scale (0: no torque; +4: very strong torque). Results: In 18 of the 32 brackets, the deflection angle {beta} was found to be > 45 and the translational force exceeded the gravitational force F{sub G} on the particular bracket (F{sub Z}: 1.2-45.7 mN). The translational force F{sub Z} was found to be up to 68.5 times greater than the gravitational force F{sub G} (F{sub Z}/F{sub G}: 1.4-68.5). The rotational force F{sub rot} was correspondingly high (+3/+4) for those brackets. For the remaining 14 objects, the deflection angles were < 45 and the torque measurements ranged from 0 to +2. The static magnetic field did not affect the titanium bracket and the ceramic bracket. No measurable translational and rotational forces were found. (orig.)

  7. NMR in High Fields and Field Gradients up to 42 T

    Science.gov (United States)

    Sigmund, Eric E.

    2002-03-01

    We describe nuclear magnetic resonance (NMR) experiments performed in fields as high as 42 T. This work was done at Northwestern University and the National High Magnetic Field Laboratory (NHMFL) with superconducting magnets, resistive Bitter-style electromagnets, and a superconducting-resistive hybrid magnet. After reviewing crucial probe and spectrometer design features, we describe the scientific and technical advantages that high field provides for two experiments. First, we studied the mixed state of the high-temperature superconductor YBa_2Cu_3O_7-x through ^17O NMR.[1] The NMR spectrum gives the field distribution associated with vortices which we use to selectively inspect regions inside and outside the vortex core. We use the spin-lattice relaxation rate (T_1-1) to probe the electronic density-of-states in this spatially resolved fashion. Second, we have studied ultraslow diffusion in glass-forming liquids such as glycerol. These studies use the high magnetic field gradient at the edge of the solenoid, which can exceed 200 T/m for the resistive magnets at the NHMFL. We employed a 4 K inductive shield to stabilize the fluctuations in the resistive magnets' applied field over the necessarily long timescales of a slow diffusion NMR experiment. We have also made use of fast frequency jumping to enhance signal-to-noise by circumventing the finite spatial excitation bandwidth imposed by the large gradient. We show NMR experiments of slow diffusion in glass-formers up to high field (H0 = 21 T, G = 220 T/m) that have resolved diffusivities as low as 10-10 cm^2/s. [1] V. F. Mitrovic et.al., Nature 413, 501-504 (2001).

  8. Operation of a 400MHz NMR magnet using a (RE:Rare Earth)Ba2Cu3O7-x high-temperature superconducting coil: Towards an ultra-compact super-high field NMR spectrometer operated beyond 1GHz.

    Science.gov (United States)

    Yanagisawa, Y; Piao, R; Iguchi, S; Nakagome, H; Takao, T; Kominato, K; Hamada, M; Matsumoto, S; Suematsu, H; Jin, X; Takahashi, M; Yamazaki, T; Maeda, H

    2014-10-18

    High-temperature superconductors (HTS) are the key technology to achieve super-high magnetic field nuclear magnetic resonance (NMR) spectrometers with an operating frequency far beyond 1GHz (23.5T). (RE)Ba2Cu3O7-x (REBCO, RE: rare earth) conductors have an advantage over Bi2Sr2Ca2Cu3O10-x (Bi-2223) and Bi2Sr2CaCu2O8-x (Bi-2212) conductors in that they have very high tensile strengths and tolerate strong electromagnetic hoop stress, thereby having the potential to act as an ultra-compact super-high field NMR magnet. As a first step, we developed the world's first NMR magnet comprising an inner REBCO coil and outer low-temperature superconducting (LTS) coils. The magnet was successfully charged without degradation and mainly operated at 400MHz (9.39T). Technical problems for the NMR magnet due to screening current in the REBCO coil were clarified and solved as follows: (i) A remarkable temporal drift of the central magnetic field was suppressed by a current sweep reversal method utilizing ∼10% of the peak current. (ii) A Z2 field error harmonic of the main coil cannot be compensated by an outer correction coil and therefore an additional ferromagnetic shim was used. (iii) Large tesseral harmonics emerged that could not be corrected by cryoshim coils. Due to those harmonics, the resolution and sensitivity of NMR spectra are ten-fold lower than those for a conventional LTS NMR magnet. As a result, a HSQC spectrum could be achieved for a protein sample, while a NOESY spectrum could not be obtained. An ultra-compact 1.2GHz NMR magnet could be realized if we effectively take advantage of REBCO conductors, although this will require further research to suppress the effect of the screening current.

  9. High-field spin dynamics of antiferromagnetic quantum spin chains

    DEFF Research Database (Denmark)

    Enderle, M.; Regnault, L.P.; Broholm, C.;

    2000-01-01

    The characteristic internal order of macroscopic quantum ground states in one-dimensional spin systems is usually not directly accessible, but reflected in the spin dynamics and the field dependence of the magnetic excitations. In high magnetic fields quantum phase transitions are expected. We...... present recent work on the high-field spin dynamics of the S = I antiferromagnetic Heisenberg chains NENP (Haldane ground state) and CsNiCl3 (quasi-1D HAF close to the quantum critical point), the uniform S = 1/2 chain CTS, and the spin-Peierls system CuGeO3. (C) 2000 Elsevier Science B,V. All rights...

  10. Design Analysis on High-field Microstrip Circulator Temperature Compensating Magnetic Circuit%高场带线环行器温度补偿磁路的设计分析

    Institute of Scientific and Technical Information of China (English)

    高昌杰; 李晓华

    2014-01-01

    According to the magnetic circuit model of the circulator,the calculation formula of temperature compen-sation of magnetic circuit is derived. Combining the simulation software ANSOFT HFSS, a more accurate analysis method of temperature compensation of magnetic circuit and the optimizing design measures are introduced. The calculated results of using the design analysis method agree with the results of test, this method will guide design and implementation of the optimal temperature compensation of magnetic circuit.%本文根据环行器实际磁路模型,对温度补偿磁路的计算公式进行了推导,并结合Ansoft HF-SS仿真软件,提出了一种温度补偿磁路的较准确计算分析方法和最佳化设计措施。该设计分析方法得到的计算结果与试验比较一致,对设计和实现最佳温度补偿磁路具有较强的指导作用。

  11. Understanding the dynamics of superparamagnetic particles under the influence of high field gradient arrays.

    Science.gov (United States)

    Barnsley, Lester C; Carugo, Dario; Aron, Miles; Stride, Eleanor

    2017-03-21

    The aim of this study was to characterize the behaviour of superparamagnetic particles in magnetic drug targeting (MDT) schemes. A 3-dimensional mathematical model was developed, based on the analytical derivation of the trajectory of a magnetized particle suspended inside a fluid channel carrying laminar flow and in the vicinity of an external source of magnetic force. Semi-analytical expressions to quantify the proportion of captured particles, and their relative accumulation (concentration) as a function of distance along the wall of the channel were also derived. These were expressed in terms of a non-dimensional ratio of the relevant physical and physiological parameters corresponding to a given MDT protocol. The ability of the analytical model to assess magnetic targeting schemes was tested against numerical simulations of particle trajectories. The semi-analytical expressions were found to provide good first-order approximations for the performance of MDT systems in which the magnetic force is relatively constant over a large spatial range. The numerical model was then used to test the suitability of a range of different designs of permanent magnet assemblies for MDT. The results indicated that magnetic arrays that emit a strong magnetic force that varies rapidly over a confined spatial range are the most suitable for concentrating magnetic particles in a localized region. By comparison, commonly used magnet geometries such as button magnets and linear Halbach arrays result in distributions of accumulated particles that are less efficient for delivery. The trajectories predicted by the numerical model were verified experimentally by acoustically focusing magnetic microbeads flowing in a glass capillary channel, and optically tracking their path past a high field gradient Halbach array.

  12. Understanding the dynamics of superparamagnetic particles under the influence of high field gradient arrays

    Science.gov (United States)

    Barnsley, Lester C.; Carugo, Dario; Aron, Miles; Stride, Eleanor

    2017-03-01

    The aim of this study was to characterize the behaviour of superparamagnetic particles in magnetic drug targeting (MDT) schemes. A 3-dimensional mathematical model was developed, based on the analytical derivation of the trajectory of a magnetized particle suspended inside a fluid channel carrying laminar flow and in the vicinity of an external source of magnetic force. Semi-analytical expressions to quantify the proportion of captured particles, and their relative accumulation (concentration) as a function of distance along the wall of the channel were also derived. These were expressed in terms of a non-dimensional ratio of the relevant physical and physiological parameters corresponding to a given MDT protocol. The ability of the analytical model to assess magnetic targeting schemes was tested against numerical simulations of particle trajectories. The semi-analytical expressions were found to provide good first-order approximations for the performance of MDT systems in which the magnetic force is relatively constant over a large spatial range. The numerical model was then used to test the suitability of a range of different designs of permanent magnet assemblies for MDT. The results indicated that magnetic arrays that emit a strong magnetic force that varies rapidly over a confined spatial range are the most suitable for concentrating magnetic particles in a localized region. By comparison, commonly used magnet geometries such as button magnets and linear Halbach arrays result in distributions of accumulated particles that are less efficient for delivery. The trajectories predicted by the numerical model were verified experimentally by acoustically focusing magnetic microbeads flowing in a glass capillary channel, and optically tracking their path past a high field gradient Halbach array.

  13. Magnetic and ultrasonic studies on stable cobalt ferrite magnetic nanofluid.

    Science.gov (United States)

    Nabeel Rashin, M; Hemalatha, J

    2014-03-01

    Stable cobalt ferrite nanofluids of various concentrations have been prepared through co-precipitation method. Structural and morphological studies of nanoparticles are made with the help of X-ray diffraction technique and Transmission Electron Microscope respectively and it is found that the particles exhibit face centered cubic structure with an average size of 14 nm. The magnetic properties of the nanofluids have been analyzed at room temperature which revealed ferromagnetic behavior and also the very low value of coupling constant which ensures the negligible interparticle interaction in the absence of magnetic field. Ultrasonic investigations have been made for the nanofluids at different temperatures and magnetic fields. The temperature effects are explained with the help of open and close-packed water structure. The inter particle interactions of surface modified CoFe2O4 particles and the cluster formation at higher concentrations are realized through the variations in ultrasonic parameters. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. High field MR imaging: magnetic field interactions of aneurysm clips, coronary artery stents and iliac artery stents with a 3.0 Tesla MR system; Hochfeld-Magnetresonanztomographie: Magnetische Anziehungs- und Rotationskraefte auf metallische Implantate bei 3,0 T

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Schmiedel, A.; Hackenbroch, M.; Hofer, U.; Urbach, H.; Traeber, F.; Schild, H. [Radiologische Univ. Bonn (Germany); Maintz, D. [Radiologische Univ. Muenster (Germany); Pavlidis, C. [Klinik fuer Neurochirurgie, Univ. Bonn (Germany); Hoeher, M. [Medizinische Univ. II Ulm (Germany)

    2004-05-01

    Purpose: to evaluate magnetic field interactions of commonly used biomedical implants at 3.0 tesla. Materials and methods: fourteen aneurysm clips designed for permanent placement in intracranial aneurysms, 19 coronary artery stents and 20 iliac artery stents were evaluated in an actively shielded compact 3.0 T MR system (Intera, Philips Medical Systems, Best, the Netherlands, length of magnet 1.57 m). The magnetic deflection forces (translational movement) were evaluated as follows: the implants were suspended by a fine string and placed in the magnet bore at the location of the maximum magnetic field gradient. The translational forces F{sub z} were calculated from the measured angle of deflection from the vertical axis. The magnetic field-induced torque (rotational forces) was evaluated as follows: each implant was placed in the center of the magnetic bore parallel to the static magnetic field B0 (position 0 ). Any possible displacement of the implant was noted on a millimeter scale and any torque qualitatively evaluated using a 5 point grading scale (0: no torque; + 4: very strong torque). The implant was turned in steps of 45 , and the procedure was repeated to encompass a full 360 rotation. Results: in 52 of the 53 devices tested, the deflection force (deflection angle: range 0-21 , translational force: range 0-3.8 mN) was less than the gravitational force (i.e., the implant's weight). These devices (n = 52/53) did not show any alignment to or rotation in the magnetic field at any of the various 45 -increment positions corresponding to a qualitative torque evaluation of grade 0/4. One device (n = 1/53), an iliac artery stent made of stainless steel (Zenith, Cook, Moenchengladbach, BRD), was found to have deflection forces (deflection angle 88 translational force 299 mN) greatly exceeding the gravitational force as well as a pronounced torque (grade 4/4). (orig.) [German] Ziel: Die In-vitro-Evaluierung verschiedener biomedizinischer Implantate hinsichtlich

  15. magnetic order studied by nuclear methods

    CERN Document Server

    Reichl, C

    2001-01-01

    investigated within the frame of this work. The studies on the highly concentrated deuterides revealed a gradual loss in local field due to a distribution of 'local Curie temperatures' depending on the number of Fe neighbours and their distances from the Moessbauer nucleus. On rising the temperature, during a magnetic transition, an increasing number of Fe sites with different local environment loose their hyperfine fields, whereas bulk measurements showed a relatively sharp, however, incomplete transition. By using a combination of neutron diffraction- and muon spin relaxation studies the complex magnetic phase diagram of the system Ce(Rh,Ru) sub 3 B sub 2 , where weak magnetic moments exist, could be studied. There, transitions from para- to ferromagnetism, and more complicated magnetic structures could be observed. Due to the existence of several isotopes of B and Ru, each carrying different nuclear spins and magnetic moment, particularly complicated second moment simulations for interpreting the muon data...

  16. The value of high-field MRI (3 T) in the assessment of sellar lesions

    Energy Technology Data Exchange (ETDEWEB)

    Pinker, K. [Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Ba-Ssalamah, A. [Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Wolfsberger, S. [Department of Neurosurgery, Medical University Vienna (Austria); Mlynarik, V. [Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Knosp, E. [Department of Neurosurgery, Medical University Vienna (Austria); Trattnig, S. [Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: siegfried.trattnig@univie.ac.at

    2005-06-01

    The aim of this study was the evaluation of the normal sellar anatomy in vitro and in vivo with high-field MRI and its application in the diagnosis of sellar pathologies in comparison to standard MRI. All high-field MR images were obtained using a 3 T Bruker Medspec 30/80 Scanner with a head birdcage transmit/receive coil and an actively shielded gradient system with a maximum gradient strength of 45 mT/m. Firstly an in vitro study of the sella turcica was performed to depict normal pituitary and sellar anatomy at high field. After a pilot-study this sequence-protocol was established: A RARE sequence (TR/TE = 7790/19 ms; matrix size, 512 x 512; RARE factor = 8, FOV, 200 mm) was used for T2-weighted coronal, axial and sagittal images. A 3D gradient echo sequence with magnetization-preparation (MP-RAGE, TR/TE/TI 33.5/7.6/800 ms, matrix size, 512 x 512; FOV, 200 mm, effective slice thickness, 1.88 mm; 3 averages) was used for acquisition of T1-weighted pre- and post-contrast images. Between January 2002 and March 200458 patients were enrolled in this study. Seven patients were examined for suspected microadenoma and in 51 patients 3T MRI was used to obtain additional information about the sellar lesion already known to be present from standard MRI. In 21 cases the accuracy of the imaging findings was assessed afterwards by comparison with intraoperative findings. The infiltration of the medial cavernous sinus wall was suspected on standard MRI on 15 sides (47%), on high-field MRI on 9 sides (28%) and could be verified by intraoperative findings on 6 sides (19%). Accordingly, sensitivity to infiltration was 83% for 3 T and 67% for standard MRI. Specificity was 84% for 3 T and 58% for standard MRI. Moreover, high-field MRI revealed microadenomas in 7 patients with a median diameter of 4 mm (range 2-9 mm). The segments of the cranial nerves were seen as mean 4 hypointense spots (range 2-5 spots) on high-field MRI in contrast to 3 spots (range 0-4 spots) on standard MRI

  17. Biodegradation reduces magnetization in oil bearing rocks: magnetization results of a combined chemical and magnetic study

    Science.gov (United States)

    Emmerton, S.; Muxworthy, A. R.; Sephton, M. A.; Williams, W.

    2012-12-01

    A relationship between hydrocarbons and their magnetic signatures has been alluded to for decades but this is the first study to combine geochemical and magnetic data. We report an extended study that identifies a definitive connection between magnetic mineralogy and biodegradation within oil-bearing rocks. Samples from Colombia, Canada Indonesia and the UK were collected and magnetically characterized. A negative linear regression in log space between magnetic susceptibility and the percentage of extractable organic matter was observed for individual reservoirs. To determine if this relationship is due to the activity of bacteria or migration of the oil, the percentage of oil components; aliphatic, aromatics, polars and resins and the biodegradation state of the samples were compared to the magnetic susceptibility and magnetic mineralogy of the samples. Geochemical biomarker data revealed that all oil samples were derived from mature type-II kerogen, which was deposited in oxygen-poor environments allowing for an investigation into biodegradation variations. Biodegradation is the decrease of oil quality through the conversion of aliphatic hydrocarbons to polar constituents mainly through the activity of bacteria. A distinct decrease in magnetic susceptibility was correlated to decreasing oil quality (loss of aliphatic hydrocarbons, more biodegraded), which cannot be rejected at 99% confidence. Further magnetic characterization revealed that the high quality, low biodegradation oils from Colombia have a higher magnetic susceptibility (10-3-10-4 m3kg-1) and are dominated by pseudo-single domain grains of magnetite. The lower quality oils i.e., the UK, Canadian and Indonesian samples, displayed decreased magnetic susceptibility (10-5-10-6 m3kg-1) and pseudo-single domain to multidomain grains of magnetite and hematite. Magnetite and pyrrhotite framboidal material were found in all but the Canadian samples. Therefore, with decreasing oil quality there is a progressive

  18. High field electron paramagnetic resonance spectroscopy under ultrahigh vacuum conditions—A multipurpose machine to study paramagnetic species on well defined single crystal surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Rocker, J.; Cornu, D.; Kieseritzky, E.; Hänsel-Ziegler, W.; Freund, H.-J. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Seiler, A. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Laboratorium für Applikationen der Synchrotronstrahlung, KIT Campus Süd, Kaiserstr. 12, 76131 Karlsruhe (Germany); Bondarchuk, O. [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); CIC energiGUNE, Parque Tecnologico, C/Albert Einstein 48, CP 01510 Minano (Alava) (Spain); Risse, T., E-mail: risse@chemie.fu-berlin.de [Fritz-Haber-Institut der MPG, Faradayweg 4-6, 14195 Berlin (Germany); Institut für Chemie und Biochemie, Freie Universität Berlin, Takustr. 3, 14195 Berlin (Germany)

    2014-08-01

    A new ultrahigh vacuum (UHV) electron paramagnetic resonance (EPR) spectrometer operating at 94 GHz to investigate paramagnetic centers on single crystal surfaces is described. It is particularly designed to study paramagnetic centers on well-defined model catalysts using epitaxial thin oxide films grown on metal single crystals. The EPR setup is based on a commercial Bruker E600 spectrometer, which is adapted to ultrahigh vacuum conditions using a home made Fabry Perot resonator. The key idea of the resonator is to use the planar metal single crystal required to grow the single crystalline oxide films as one of the mirrors of the resonator. EPR spectroscopy is solely sensitive to paramagnetic species, which are typically minority species in such a system. Hence, additional experimental characterization tools are required to allow for a comprehensive investigation of the surface. The apparatus includes a preparation chamber hosting equipment, which is required to prepare supported model catalysts. In addition, surface characterization tools such as low energy electron diffraction (LEED)/Auger spectroscopy, temperature programmed desorption (TPD), and infrared reflection absorption spectroscopy (IRAS) are available to characterize the surfaces. A second chamber used to perform EPR spectroscopy at 94 GHz has a room temperature scanning tunneling microscope attached to it, which allows for real space structural characterization. The heart of the UHV adaptation of the EPR experiment is the sealing of the Fabry-Perot resonator against atmosphere. To this end it is possible to use a thin sapphire window glued to the backside of the coupling orifice of the Fabry Perot resonator. With the help of a variety of stabilization measures reducing vibrations as well as thermal drift it is possible to accumulate data for a time span, which is for low temperature measurements only limited by the amount of liquid helium. Test measurements show that the system can detect paramagnetic

  19. Study of HTS Wires at High Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    Turrioni, D.; Barzi, E.; Lamm, M.J.; Yamada, R.; Zlobin, A.V.; Kikuchi, A.; /Fermilab

    2009-01-01

    Fermilab is working on the development of high field magnet systems for ionization cooling of muon beams. The use of high temperature superconducting (HTS) materials is being considered for these magnets using Helium refrigeration. Critical current (I{sub c}) measurements of HTS conductors were performed at FNAL and at NIMS up to 28 T under magnetic fields at zero to 90 degree with respect to the sample face. A description of the test setups and results on a BSCCO-2223 tape and second generation (2G) coated conductors are presented.

  20. High-field paramagnetic Meissner effect and flux creep in low-T c Ti-V alloy superconductors

    Science.gov (United States)

    Matin, M.; Chattopadhyay, M. K.; Sharath Chandra, L. S.; Roy, S. B.

    2016-02-01

    We report an experimental study on the high-field paramagnetic Meissner effect (HFPME) performed by measuring both the temperature and time dependence of magnetization in the two compositions of superconducting Ti-V alloys where certain secondary phases are non-superconducting, and thereby act as efficient pinning centres for the flux lines. While spatially non-uniform flux density driven by flux line pinning at these secondary phases is the necessary condition for the observation of the HFPME, our study indicates that the flux creep effect plays a supplementary role to reinforce the HFPME. It is found that in the temperature and magnetic field regime of the HFPME, the field-cooled magnetization of these samples relaxes monotonically towards a more positive value with elapsed time. We comment on how this paramagnetic relaxation behaviour of the field-cooled magnetization is correlated with the unusual thermo-magnetic responses related to the HFPME.

  1. High-Field Electron Paramagnetic Resonance and Density Functional Theory Study of Stable Organic Radicals in Lignin: Influence of the Extraction Process, Botanical Origin, and Protonation Reactions on the Radical g Tensor.

    Science.gov (United States)

    Bährle, Christian; Nick, Thomas U; Bennati, Marina; Jeschke, Gunnar; Vogel, Frédéric

    2015-06-18

    The radical concentrations and g factors of stable organic radicals in different lignin preparations were determined by X-band EPR at 9 GHz. We observed that the g factors of these radicals are largely determined by the extraction process and not by the botanical origin of the lignin. The parameter mostly influencing the g factor is the pH value during lignin extraction. This effect was studied in depth using high-field EPR spectroscopy at 263 GHz. We were able to determine the gxx, gyy, and gzz components of the g tensor of the stable organic radicals in lignin. With the enhanced resolution of high-field EPR, distinct radical species could be found in this complex polymer. The radical species are assigned to substituted o-semiquinone radicals and can exist in different protonation states SH3+, SH2, SH1-, and S2-. The proposed model structures are supported by DFT calculations. The g principal values of the proposed structure were all in reasonable agreement with the experiments.

  2. High magnetic field studies of the hidden order transition in URu2Si2.

    Science.gov (United States)

    Jaime, M; Kim, K H; Jorge, G; McCall, S; Mydosh, J A

    2002-12-31

    We studied in detail the low temperature/high magnetic field phases of URu2Si2 single crystals with specific heat, magnetocaloric effect, and magnetoresistance in magnetic fields up to 45 T. Data obtained down to 0.5 K, and extrapolated to T=0, show a suppression of the hidden-order phase at H0(0)=35.9+/-0.35 T and the appearance of a new phase for magnetic fields in excess of H1(0)=36.1+/-0.35 T observed only at temperatures lower than 6 K. In turn, complete suppression of this high field state is attained at a critical magnetic field H2(0)=39.7+/-0.35 T. No phase transitions are observed above 40 T. We discuss our results in the context of itinerant versus localized f electrons.

  3. Quadrature Slotted Surface Coil Pair for Magnetic Resonance Imaging at 4 Tesla: Phantom Study

    Directory of Open Access Journals (Sweden)

    Solis S.E.

    2012-01-01

    Full Text Available A coil array was composed of two slotted surface coils forming a structure with two plates at 900, each one having 6 circular slots and is introduced in this paper. Numerical simulations of the magnetic field of this coil array were performed at 170 MHz using the finite element method to study its behaviour. This coil array was developed for brain magnetic resonance imaging to be operated at the resonant frequency of 170 MHz in the transceiver mode and quadrature driven. Numerical simulations demonstrated that electromagnetic interaction between the coil elements is negligible, and that the magnetic field showed a good uniformity. Phantom images were acquired with our coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. In vitro images showed the feasibility of this coil array for standard pulses and high field magnetic resonance imaging.

  4. High field superconductor development and understanding project, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Larbalestier, David C.; Lee, Peter J.

    2009-07-15

    Over 25 years the Applied Superconductivity Center at the University of Wisconsin-Madison provided a vital technical resource to the High Energy Physics community covering development in superconducting strand for HEP accelerator magnet development. In particular the work of the group has been to develop the next generation of high field superconductors for high field application. Grad students Mike Naus, Chad Fischer, Arno Godeke and Matt Jewell improved our understanding of the microstructure and microchemistry of Nb3Sn and their impact on the physical and mechanical properties. The success of this work has led to the continued funding of this work at the ASC after it moved to the NHMFL and also to direct funding from BNL for some aspects of Nb3Sn cable evaluation.

  5. Studies of Solar Vector Magnetic Field

    Institute of Scientific and Technical Information of China (English)

    WANG Jingxiu

    2011-01-01

    In this article, we report a few advances in the studies based on the solar vector magnetic field observations which were carried out mainly with the Solar Magnetic Field Telescope at the Huairou Solar Observing Station in the 1990s. (1) We developed necessary methodology and concepts in vector magnetogram analysis (Wang et al. 1996). For the first time, we proposed to use the photospheric free magnetic energy to quantify the major flare productivity of solar active regions (ARs), and it had been proved to be the best parameter in representing the major flare activity. (2) We revealed that there was always a dominant sense of magnetic shear in a given AR (Wang 1994), which was taken as the premise of the helicity calculation in ARs; we made the first quantitative estimation of magnetic helicity evolution in ARs (Wang 1996). (3) We identified the first group of evidence of magnetic reconnection in the lower solar atmosphere with vector magnetic field observations and proposed a two-step reconnection flare model to interpret the observed association of flux cancellation and flares (Wang and Shi 1993). Efforts to quantify the major flare productivity of super active regions with vector magnetic field observations have been also taken.

  6. Role of high-field MR systems in neuroscience

    Energy Technology Data Exchange (ETDEWEB)

    Nakada, Tsutomu [Niigata Univ. (Japan). Brain Research Inst

    1999-07-01

    Nuclear magnetic resonance (NMR) is a remarkably versatile technology applicable to various aspects of medical science. Currently, there are three categories of MR techniques available for probing human brain function in detail. The first category comprises the most widely utilized techniques which make use of the metabolic effects of brain activation, represented by BOLD functional magnetic resonance imaging (fMRI) and EPISTAR cerebral blood flow imaging. The second category of techniques deals with apparent diffusion tensor in probing the cellular aspects of brain function and is represented by magnetic resonance axonography (MRX). The third category of techniques is the oldest and as yet the most underutilized. These techniques which include MR spectroscopy (MRS) and spectroscopic imaging (SI), are based on classical NMR spectroscopy and are capable of providing biochemical information in vivo. In these critically important but highly demanding techniques, high-field systems possess significant advantages over conventional systems. (author)

  7. Interaction of magnetic resonators studied by the magnetic field enhancement

    Science.gov (United States)

    Hou, Yumin

    2013-12-01

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters-shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  8. Interaction of magnetic resonators studied by the magnetic field enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Hou, Yumin, E-mail: ymhou@pku.edu.cn [State Key Laboratory for Mesoscopic Physics, School of Physics, Peking University, Beijing 100871 (China)

    2013-12-15

    It is the first time that the magnetic field enhancement (MFE) is used to study the interaction of magnetic resonators (MRs), which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  9. Interaction of magnetic resonators studied by the magnetic field enhancement

    Directory of Open Access Journals (Sweden)

    Yumin Hou

    2013-12-01

    Full Text Available It is the first time that the magnetic field enhancement (MFE is used to study the interaction of magnetic resonators (MRs, which is more sensitive than previous parameters–shift and damping of resonance frequency. To avoid the coherence of lattice and the effect of Bloch wave, the interaction is simulated between two MRs with same primary phase when the distance is changed in the range of several resonance wavelengths, which is also compared with periodic structure. The calculated MFE oscillating and decaying with distance with the period equal to resonance wavelength directly shows the retardation effect. Simulation also shows that the interaction at normal incidence is sensitive to the phase correlation which is related with retardation effect and is ultra-long-distance interaction when the two MRs are strongly localized. When the distance is very short, the amplitude of magnetic resonance is oppressed by the strong interaction and thus the MFE can be much lower than that of single MR. This study provides the design rules of metamaterials for engineering resonant properties of MRs.

  10. Selected studies of magnetism at high pressure

    Energy Technology Data Exchange (ETDEWEB)

    Hearne, G.R. [University of the Witwatersrand, Johannesburg (South Africa). Dept. of Physics; Pasternak, M.P. [Tel-Aviv Univ. (Israel). School of Physics and Astronomy; Taylor, R.D. [Los Alamos National Lab., NM (United States)

    1995-09-01

    Most previous studies of magnetism in various compounds under extreme conditions have been conducted over a wide pressure range at room temperature or over a wide range of cryogenic temperatures at pressures below 20 GPa (200 kbar). We present some of the most recent studies of magnetism over an extended range of temperatures and pressures far beyond 20 GPa, i.e., in regions of pressure-temperature (P-T) where magnetism has been largely unexplored. Recent techniques have permitted investigations of magnetism in selected 3d transition metal compounds in regions of P-T where physical properties may be drastically modified; related effects have often been seen in selected doping studies at ambient pressures.

  11. Study of Magnetic Nanocomposites by NMR and Bulk Magnetization Techniques

    Directory of Open Access Journals (Sweden)

    Matveev V.

    2014-07-01

    Full Text Available Magnetic nanocomposites possess complex and nonuniform magnetic structure. As a result it is necessary to use different physical methods to describe their properties. In this work we have applied a combination of micro and macro approaches to understand more deeply magnetic properties of some cobaltcontaining nanocomposites. Testing of magnetic structure of the samples at molecular level was done with NMR and Mössbauer techniques whereas static (SQUID and dynamic magnetic (M2, see below measurements – at macro level.

  12. Study on Magnetic Responsibility of Rare Earth Ferrite/Polyacrylamide Magnetic Microsphere

    Institute of Scientific and Technical Information of China (English)

    Zhang Ming; Wang Zhifeng; Zhang Hong; Dai Shaojun; Qiu Guanming; Okamoto Hiroshi

    2005-01-01

    In inverse microemulsion, rare earth ferrite/polyacrylamide magnetic microsphere were prepared and their magnetic responsibility were studied by magnetic balance. Results indicate that the magnetic responsibility of microsphere relates to magnetic moment of rare earth ion, and it can be improved by the addition of dysprosium ion of high magnetic moment. Dysprosium content has an effect on magnetic responsibility of dysprosium ferrite/polyacrylamide magnetic microsphere. The microsphere displays strong magnetic responsibility when the molar ratio of Dy3+/iron is 0.20.

  13. New types of high field pinning centers and pinning centers for the peak effect

    Science.gov (United States)

    Gajda, Daniel; Zaleski, Andrzej; Morawski, Andrzej; Hossain, Md Shahriar A.

    2017-08-01

    In this article, we report the results of a study that shows the existence of pinning centers inside grains and between grains in NbTi wires. We accurately show the ranges of magnetic fields in which the individual pinning centers operate. The pinning centers inside grains are activated in high magnetic fields above 6 T. We show the range of magnetic fields in which individual defects, dislocations, precipitates inside grains and substitutions in the crystal lattice can operate. We show the existence of a new kind of high field pinning center, which operates in high magnetic fields from 8 to ˜9.5 T. We indicate that dislocations create pinning centers in the range of magnetic fields from 6 to 8 T. In addition, our measurements suggest that the peak effect (increased critical current density (J c) near the upper critical field (B c2)) could be attributed to martensitic (needle-shaped) α‧-Ti inclusions inside grains. These centers are very important because they work very effectively in magnetic fields above 9.5-10 T. We also show that the α-Ti precipitates (between grains) with a thickness similar to the coherence length create pinning centers which work very effectively in magnetic fields from 3 to 6 T. In magnetic fields below 3 T, they act very efficiently in grain boundaries. The measurements indicate that the pinning centers created by dislocations only can be tested by transport measurements. This indicates that dislocations do not increase the magnetic critical current density (J cm). Cold drawing improves pinning centers at grain boundaries and increases the dislocation density, and cold-drawing pinning centers are responsible for the peak effect.

  14. First principles study of magnetism in nanographenes

    CERN Document Server

    Jiang, De-en; Dai, Sheng

    2007-01-01

    Magnetism in nanographenes (also know as polycyclic aromatic hydrocarbons, or PAHs) are studied with first principles density functional calculations. We find that an antiferromagnetic (AFM) phase appears as the PAH reaches a certain size. This AFM phase in PAHs has the same origin as the one in infinitely long zigzag-edged graphene nanoribbons, namely, from the localized electronic state at the zigzag edge. The smallest PAH still having an AFM ground state is identified. With increased length of the zigzag edge, PAHs approach an infinitely long ribbon in terms of (1) the energetic ordering and difference among the AFM, ferromagnetic (FM), and nonmagnetic (NM) phases and (2) the average local magnetic moment at the zigzag edges. These PAHs serve as ideal targets for chemical synthesis of nanographenes that possess magnetic properties. Moreover, our calculations support the interpretation that experimentally observed magnetism in activated carbon fibers originates from the zigzag edges of the nanographenes.

  15. Discrimination of soybean oil adulterated frying oil by high-field nuclear magnetic resonance%煎炸老油掺伪大豆油的高场核磁检测

    Institute of Scientific and Technical Information of China (English)

    李玉邯; 陈宇飞; 杨柳; 王维坚

    2016-01-01

    通过高场核磁共振仪检测了纯大豆油和掺伪了煎炸老油的大豆油并对谱图进行积分。通过谱图对比发现了三个鉴别指标,第一个鉴别指标是在δ=1.58处,纯大豆油有明显特征峰,而煎炸老油在该处无特征峰;第二个鉴别指标是在δ=2.77~2.84处,纯大豆油特征峰的积分面积高于掺伪了煎炸老油的大豆油(添加50%煎炸老油积分面积为1.51,纯大豆油积分面积为2.04),并且随着煎炸老油添加量的增加积分面积逐渐减小;第三个鉴别指标是在δ=5.25~5.42处,纯大豆油特征峰的积分面积明显高于掺伪了煎炸老油的大豆油(添加50%煎炸老油积分面积为3.98,纯大豆油积分面积为4.87),而且也随着煎炸老油添加量的增加积分面积逐渐减小。%The pure soybean oil and frying soybean oil were detected by high–field nuclear magnetic resonance instrument and the spectrograms were integrated. There were three identification methods. The first one was characteristic peak atδ=1.58 which could be detected obviously in the pure oil and couldn’t be detected in frying soybean oil. The second was atδ=2.77~2.84,where the integral area of pure soybean was higher than the frying oil (the integral area of add 50%frying oil was 1.51,and the integral area of pure soybean oil was 2.04). The third was atδ=5.25~5.42,where the integral area of pure soybean was also significantly higher than the frying oil(the integral area of add 50%frying oil was 3.98,the integral area of pure soybean oil was 4.87). And with the addition of frying oil,the integral area decreased.

  16. Magnetic study of the Furnas caldera (Azores

    Directory of Open Access Journals (Sweden)

    J. M. Torta

    1997-06-01

    Full Text Available A local ground magnetic study of the Furnas caldera (S. Miguel Island, Azores has provided new insight into the magnetic structure of this volcano. Analysis of the data comprised removal of the IGRF, reduction to the pole, pseudogravity integration and upward continuation. Also, a spectral method was applied to estimate the depth to the magnetic sources, as well as a 2.5D forward modelling technique. Magnetic properties obtained at the laboratory for some representative sample rocks were considered in the modelling process. The most relevant features are the existence of an important negative anomaly inside the caldera and of an intense positive anomaly to the south of the coast. The former points out a decrease in the magnetization of the caldera filling materials with respect to the surrounding rocks, which could be explained as the result of post-eruption processes such as hydrothermal alteration. This is expected as Furnas has an active hydrothermal system probably related with a magmatic reservoir at high temperature. The positive anomaly suggests the existence of a strongly-magnetized body beneath the south coast.

  17. High Field Seeking State Atom Laser and Properties of Flux

    Institute of Scientific and Technical Information of China (English)

    XIA Lin; XIONG Wei; YANG Fan; YI Lin; ZHOU Xiao-Ji; CHEN Xu-Zong

    2008-01-01

    We present an experimental study on the continuous atom laser. The experiments show that a high field seeking state atom laser with stable flux can be formed by increasing the strength of outcoupling before large density fluctuations appear. It is easy to obtain a long length or high speed output with this kind of atom laser.

  18. High field MREIT: setup and tissue phantom imaging at 11 T

    Science.gov (United States)

    Sadleir, Rosalind; Grant, Samuel; Zhang, Sung Uk; Oh, Suk Hoon; Lee, Byung Il; Woo, Eung Je

    2008-01-01

    Magnetic resonance electrical impedance tomography (MREIT) has the potential to provide conductivity and current density images with high spatial resolution and accuracy. Recent experimental studies at a field strength of 3 T showed that the spatial resolution of conductivity and current density images may be similar to that of conventional MR images as long as enough current is injected, at least 20 mA when the object being imaged has a size similar to the human head. To apply the MREIT technique to image small conductivity changes using less injection current, we performed MREIT studies at 11 T field strength, where noise levels in measured magnetic flux density data are significantly lower. In this paper we present the experimental results of imaging biological tissues with different conductivity values using MREIT at 11 T. We describe technical difficulties encountered in using high-field MREIT systems and possible solutions. High-field MREIT is suggested as a research tool for obtaining accurate conductivity data from tissue samples and animal subjects. PMID:16636417

  19. High-field dipoles for future accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Wipf, S.L.

    1984-09-01

    This report presents the concept for building superconducting accelerator dipoles with record high fields. Economic considerations favor the highest possible current density in the windings. Further discussion indicates that there is an optimal range of pinning strength for a superconducting material and that it is not likely for multifilamentary conductors to ever equal the potential performance of tape conductors. A dipole design with a tape-wound, inner high-field winding is suggested. Methods are detailed to avoid degradation caused by flux jumps and to overcome problems with the dipole ends. Concerns for force support structure and field precision are also addressed. An R and D program leading to a prototype 11-T dipole is outlined. Past and future importance of superconductivity to high-energy physics is evident from a short historical survey. Successful dipoles in the 10- to 20-T range will allow interesting options for upgrading present largest accelerators.

  20. Background field coils for the High Field Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Zbasnik, J.P.; Cornish, D.N.; Scanlan, R.M.; Jewell, A.M.; Leber, R.L.; Rosdahl, A.R.; Chaplin, M.R.

    1980-09-22

    The High Field Test Facility (HFTF), presently under construction at LLNL, is a set of superconducting coils that will be used to test 1-m-o.d. coils of prototype conductors for fusion magnets in fields up to 12 T. The facility consists of two concentric sets of coils; the outer set is a stack of Nb-Ti solenoids, and the inner set is a pair of solenoids made of cryogenically-stabilized, multifilamentary Nb/sub 3/Sn superconductor, developed for use in mirror-fusion magnets. The HFTF system is designed to be parted along the midplane to allow high-field conductors, under development for Tokamak fusion machines, to be inserted and tested. The background field coils were wound pancake-fashion, with cold-welded joints at both the inner and outer diameters. Turn-to-turn insulation was fabricated at LLNL from epoxy-fiberglass strip. The coils were assembled and tested in our 2-m-diam cryostat to verify their operation.

  1. Condromalácia de patela: comparação entre os achados em aparelhos de RM de alto e baixo campo magnético Chondromalacia patellae: comparison of high-field strength versus low-field strength magnetic resonance imaging findings

    Directory of Open Access Journals (Sweden)

    Maxime Figueiredo de Oliveira Freire

    2006-06-01

    Full Text Available OBJETIVO: Comparar os aparelhos de ressonância magnética de baixo campo e de alto campo para estudo da cartilagem articular da patela. MATERIAIS E MÉTODOS: Foi realizado estudo usando as seqüências GRE 2D, GRE 3D, FSE T2 e STIR (baixo campo e TSE T2 SPIR. Cada seqüência foi analisada separadamente para o estudo da cartilagem, sem o conhecimento dos dados do paciente e do resultado das outras seqüências, sendo atribuído grau de lesão de 0 a 3 e descrita a sua localização. Os resultados de concordância e discordância foram analisados pelos testes de Kappa e McNemar. RESULTADOS: Na faceta medial houve baixas concordâncias e as discordâncias mostraram significativa superestimação. Na faceta lateral houve boas concordâncias e as discordâncias não foram significativas. No ápice houve boas concordâncias e as discordâncias mostraram significativa subestimação. CONCLUSÃO: A seqüência STIR teve a melhor concordância com a seqüência TSE T2 SPIR. Lesões de alto grau são mais bem caracterizadas pelas seqüências do aparelho de baixo campo. Áreas de aumento de sinal dificultam o estudo da cartilagem da faceta medial da patela no aparelho de baixo campo.OBJECTIVE: To compare the performance of low-field-strength and high-field-strength magnetic resonance imaging equipments for evaluation of the patella articular cartilage. MATERIALS AND METHODS: The study was developed using GRE 2D, GRE 3D, FSE T2, STIR sequences (low-field and TSE T2 SPIR sequence. Each sequence has been separately analyzed for evaluation of the cartilage without knowledge of other sequences results or any patients data; the lesion was assigned a grade from 0 to 3 and had its location defined. Agreement and disagreement results were analyzed by Kappa and McNemar tests. RESULTS: Medial facet has presented low agreement index and disagreements showed to be significantly overestimated. Lateral facet has presented a reasonable agreement index and disagreement

  2. Photoemission and magnetic circular dichroism studies of magnetic semiconductors

    Science.gov (United States)

    Fujimori, Atsushi

    2005-03-01

    Recently, a series of novel ferromagnetic semiconductors have been synthesized using MBE and related techniques and have attracted much attention because of unknown mechanisms of carrier-induced ferromagnetism and potential applications as "spin electronics" devices. Some new materials show ferromagnetism even well above room temperature. Photoemission spectroscopy has been used to study the d orbitals of the dilute transition-metal atoms, mostly Mn, and their hybridization with the host band states [1]. Soft x-ray absorption spectroscopy (XAS) and magnetic circular dichroism (MCD) at the transition-metal 2p-3d absorption edges are useful techniques to study the valence and spin states of the transition-metal atoms. Furthermore, since MCD has different sensitivities to the ferromagnetic and paramagnetic components at different temperatures and magnetic fileds, if the sample is a mixture of ferromagnetic and non-ferromagnetic transition- metal atoms, it can be used to separate the two components and to study their electronic structures. In this talk, results are presented for the prototypical diluted ferromagnetic semiconductor Ga1-xMnxAs [2] and the room-temperature ferromagnets Zn1-xCoxO and Ti1-xCoxO2.I acknowledge collaboration with Y. Ishida, J.-I. Hwang, M. Kobayashi, Y. Takeda, Y. Saitoh, J. Okamoto, T. Okane, Y. Muramatsu, K. Mamiya, T. Koide, A. Tanaka, M. Tanaka, Hayashi, S. Ohya, T. Kondo, H. Munekata, H. Saeki, H. Tabata, T. Kawai, Y. Matsumoto, H. Koinuma, T. Fukumura and M. Kawasaki. This work was supported by a Grant-in-Aid for Scientific Research in Priority Area "Semiconductor nano-spintronics" (14076209) from MEXT, Japan.1. J. Okabayashi et al., Phys. Rev. B 64, 125304 (2001).2. A. Fujimori et al., J. Electron Spectrosc. Relat. Phenom., in press.

  3. Magnetic microwires a magneto-optical study

    CERN Document Server

    Chizhik, Alexander

    2014-01-01

    PrefaceKerr Effect as Method of Investigation of Magnetization Reversal in Magnetic Wires Cold-Drawn Fe-Rich Amorphous Wire Conventional Co-Rich Amorphous WireInteraction Between Glass-Covered MicrowiresCircular Magnetic Bistability in Co-Rich Amorphous Microwires Effect of High-Frequency Driving Current on Magnetization Reversal in Co-Rich Amorphous MicrowiresRelation Between Surface Magnetization Reversal and Magnetoimpedance Helical Magnetic Structure Magnetization Reversal in Crossed Magnetic Field Visualization of Barkhausen Jump Magnetizatio

  4. Office-based versus high-field strength MRI: diagnostic and technical considerations.

    Science.gov (United States)

    Sanal, Hatice Tuba; Cardoso, Fabiano; Chen, Lina; Chung, Christine

    2009-03-01

    Low-field office magnetic resonance scanners have been an exciting, innovative, and controversial development in medical imaging. These units boost cost efficiency, with ease of installation and no additional external radiofrequency shielding necessary. The open design enables imaging of those who are claustrophobic and overweight, and offer the potential of dynamic imaging for athletes. Experienced centers have reported that the diagnostic accuracy obtained with office-based systems is satisfactory and comparable with that of high-field systems. However, with the advantages afforded by these convenient units, some significant limitations owing primarily to decreased signal-to-noise ratio of low-field MR imaging and lower image quality compared with conventional high-field magnetic resonance scanners. In this article, we comprehensively reviewed the literature focusing on the diagnostic accuracy of low-field imaging with respect to individual joints and the major pathology that occur in these joints. According to most studies, there are still a number of patients in whom clinical treatment is affected owing to under or misdiagnosis by low-field MR imaging. For clinicians and radiologists who are an integral part of this office-based diagnostic system, it is important to be knowledgeable of the potential limitations of these low-field scanners compared with conventional systems. Specialized training and expertize is required to optimize imaging parameters, and provide quality control and accurate interpretation.

  5. Holocene Environmental Magnetic Studies in northeastern Taiwan

    Science.gov (United States)

    Lee, T.; Yang, T.

    2010-12-01

    This study will present the environmental magnetic results analyzed from two lacustrine sediment cores raised from Ta-Hu Lake of Ilan County at northeastern Taiwan. The total recovered length of core DH-7A is of about 53.3 meters and that of the core DH-7B is of about 35.5 meters. Based on the C-14 dating, the former core could provide the information for the whole Holocene and the later one could support the data at least for the last 7,600 years. For those magnetic proxies representing the abundant variation of magnetic minerals, such as SIRM, bIRM, ARM, HIRM etc., show very spiky patterns. High abundant signals are usually accompanied by increasing of the fine grain signal (ARM/χ) and decreasing the S-ratio. Based on the difference between the magnetic results of the two cores and the analysis of organic matters of the core, these spikes might represent the flooding events brought the sediments from the outside drainage area into the lake due to severe heavy rainfalls in the area studied. In addition, based on the characteristic variation patterns of the used magnetic proxies several periods could be delimited. Higher sedimentation rate could be found at the two periods, 7600~5800 yrB.P. and 2000~500 yrB.P., which is of about 3-4 times of the others. Also their magnetic signals changed much frequent than the others. The results may related to the strengthen/weaken evolution of the East Asia monsoon.

  6. Magnetic studies of dusts in the urban environment

    CERN Document Server

    Xie, S

    2000-01-01

    non-destructive magnetic measurements may be used as proxies for the organic matter content in street dust. Associations between magnetic properties and element concentrations are investigated by using correlation analysis and factor analysis, which may be a potential approach for source identification of magnetic material in the environment. The study suggests that ferrimagnetic minerals are the dominant magnetic component in Bootle dust samples. Both studied sites show similar magnetic properties, but they can be differentiated using some magnetic parameters, such as chi LF, SIRM, and Hcr / Hc. The difference of magnetic properties in two sites may provide a potential application of magnetic techniques in the study of dust sources in the urban environment. This study makes a useful contribution to environmental magnetism, especially the application of magnetic techniques to the study of dusts in the urban environment. The results also have practical implications for pollution studies in Liverpool and Bootle...

  7. Formation of magnetic filaments: A kinetic study

    Science.gov (United States)

    Martínez-Pedrero, F.; Tirado-Miranda, M.; Schmitt, A.; Callejas-Fernández, J.

    2007-07-01

    In order to form magnetic filaments or chains, aqueous suspensions of superparamagnetic colloidal particles were aggregated under the action of an external magnetic field in the presence of different amounts of an indifferent 1:1 electrolyte (KBr). This allowed the influence of the anisotropic magnetic and isotropic electrostatic interactions on the aggregation behavior of these electric double-layered magnetic particles to be studied. Dynamic light scattering was used for monitoring the average diffusion coefficient of the magnetic filaments formed. Hydrodynamic equations were employed for obtaining the average chain lengths from the experimental mean diffusion coefficients. The results show that, for the same exposure time to the magnetic field, the average filament size is monotonously related to the amount of electrolyte added. The chain growth behavior was found to follow a power law with a similar exponent for all electrolyte concentrations used in this work. The time evolution of the average filament size can be rescaled such that all the curves collapse on a single master curve. Since the electrolyte added does not have any effect on the scaling behavior, the mechanism of aggregation seems to be completely controlled by the dipolar interaction. However, electrolyte addition not only controls the range of the total interaction between the particles, but also enhances the growth rate of the aggregation process. Taking into account the anisotropic character of these aggregation processes we propose a kernel that depends explicitly on the range of the dipolar interaction. The corresponding solutions of the Smoluchowski equation combined with theoretical models for the diffusion and light scattering by rigid rods reproduce the measured time evolution of the average perpendicular aggregate diffusion coefficient quite satisfactorily.

  8. Magnetic Nozzle Simulation Studies for Electric Propulsion

    Science.gov (United States)

    Tarditi, Alfonso

    2010-11-01

    Electric Propulsion has recently re-gained interest as one of the key technologies to enable NASA's long-range space missions. Options are being considered also in the field of aneutronic fusion propulsion for high-power electric thrusters. To support these goals the study of the exhaust jet in a plasma thruster acquires a critical importance because the need of high-efficiency generation of thrust. A model of the plasma exhaust has been developed with the 3D magneto-fluid NIMROD code [1] to study the physics of the plasma detachment in correlation with experimentally relevant configurations. The simulations show the role of the plasma diamagnetism and of the magnetic reconnection process in the formation of a detached plasma. Furthermore, in direct fusion-propulsion concepts high-energy (MeV range) fusion products have to be efficiently converted into a slower and denser plasma jet (with specific impulse down to few 1000's seconds, for realistic missions in the Solar System). For this purpose, a two-stage conversion process is being modeled where high-energy ions are non-adiabatically injected and confined into a magnetic duct leading to the magnetic nozzle, transferring most of their energy into their gyro-motion and drifting at slower speed along with the plasma propellant. The propellant acquires then thermal energy that gets converted into the direction of thrust by the magnetic nozzle. [1] C. R. Sovinec et al., J. Comput. Phys. 195, 355 (2004).

  9. A feasibility study of magnetic separation of magnetic nanoparticle for forward osmosis.

    Science.gov (United States)

    Kim, Y C; Han, S; Hong, S

    2011-01-01

    It was recently reported that a UK company has developed a naturally non-toxic magnetoferritin to act as a draw solute for drawing water in forward osmosis process. The gist of this technology is the utilization of the magnetic nanoparticle and high-gradient magnetic separation for draw solute separation and reuse. However, any demonstration on this technology has not been reported yet. In this study, a feasibility test of magnetic separation using magnetic nanoparticle was therefore performed to investigate the possibility of magnetic separation in water treatment such as desalination. Basically, a magnetic separation system consisted of a column packed with a bed of magnetically susceptible wools placed between the poles of electromagnet and Fe3O4 magnetic nanoparticle was used as a model nanoparticle. The effect of nanoparticle size to applied magnetic field in separation column was experimentally investigated and the magnetic field distribution in a magnet gap and the magnetic field gradient around stainless steel wool wire were analyzed through numerical simulation. The amount of magnetic nanoparticle captured in the separator column increased as the magnetic field strength and particle size increased. As a result, if magnetic separation is intended to be used for draw solute separation and reuse, both novel nanoparticle and large-scale high performance magnetic separator must be developed.

  10. Spin canting observation and cation distribution in CoFe{sub 2−x}In{sub x}O{sub 4} (0.0 ⩽ x ⩽ 1.0) ferrites through low temperature–high field Mössbauer spectral study

    Energy Technology Data Exchange (ETDEWEB)

    Pandit, Rabia, E-mail: rabiabest@gmail.com [Department of Physics, National Institute of Technology, Hamirpur (H.P) 177 005 (India); Sharma, K.K.; Kaur, Pawanpreet [Department of Physics, National Institute of Technology, Hamirpur (H.P) 177 005 (India); Reddy, V.R. [UGC-DAE Consortium for Scientific Research, Khandwa Road, Indore 4520 17 (India); Kumar, Ravi [Centre for Material Science and Engineering, National Institute of Technology, Hamirpur (H.P) 177 005 (India); Shah, Jyoti [National Physical Laboratory, New Delhi 110 012 (India)

    2014-05-01

    Highlights: • Rietveld refinement of CoIn{sub x}Fe{sub 2−x}O{sub 4} samples confirm single phase spinel structure. • The in-field Mössbauer study reveals canted spin structures in CoIn{sub x}Fe{sub 2−x}O{sub 4} ferrites. • In-field Mössbauer study is in line with magnetization measurements. • Cation distribution matches well with experimental integrated intensity ratios. • Shifting of resonance peaks to high frequencies is useful for industrial purposes. - Abstract: In the present work, In{sup 3+} substituted cobalt ferrites (CoFe{sub 2−x}In{sub x}O{sub 4}, x = 0.0, 0.2, 0.4, 0.6, 0.8, 1.0) have been synthesized via solid-state reaction technique. The Rietveld fitted X-ray diffraction patterns confirm the formation of single phase cubic spinel structure with space group Fd3{sup ¯}m for all the samples, with additional slight traces of secondary phase for x = 0.6, 0.8 and 1.0 samples. The low temperature (5 K)–high field Mössbauer (5T) spectra are analyzed in detail for probing the magnetic properties of Fe based In{sup 3+} substituted cobalt ferrites. The canted spin structures associated with Fe{sup 3+} ions both at A- and B-sites in the presence of external magnetic field of 5T have been noticed in all the samples. A fair agreement is obtained between the experimental integrated intensity ratios of {sup 57}Fe Mössbauer spectra at A- and B-sites and those calculated on the basis of cation distribution. The effect of In{sup 3+} substitution on various Mössbauer parameters viz hyperfine field distribution, isomer shift, quadrupole splitting and the line width has also been noticed. The magnetization measurements performed at low temperature also reveal the canted spin structures in all the samples. The variations in initial permeability over a wide range of frequency (125 kHz–30 MHz) at 300 K have also been recorded. The initial permeability study reveals the occurrence of resonance phenomenon at very high frequencies which widens the area

  11. High field Q slope and the baking effect: Review of recent experimental results and new data on Nb heat treatments

    Directory of Open Access Journals (Sweden)

    G. Ciovati

    2010-02-01

    Full Text Available The performance of superconducting radio-frequency (SRF cavities made of bulk Nb at high fields (peak surface magnetic field greater than about 90 mT is characterized by exponentially increasing rf losses (high-field Q slope, in the absence of field emission, which are often mitigated by low-temperature (100–140°C, 12–48 h baking. In this contribution, recent experimental results and phenomenological models to explain this effect will be briefly reviewed. New experimental results on the high-field Q slope will be presented for cavities that had been heat treated in a vacuum furnace at high temperature without subsequent chemical etching. These studies are aimed at understanding the role of hydrogen on the high-field Q slope and at the passivation of the Nb surface during heat treatment. Improvement of the cavity performances, particularly of the cavities’ quality factor, have been obtained following the high-temperature heat treatments, while secondary ion mass spectroscopy surface analysis measurements on Nb samples treated with the cavities revealed significantly lower hydrogen concentration than for samples that followed standard cavity treatments.

  12. NUMERICAL STUDIES OF WEAKLY STOCHASTIC MAGNETIC RECONNECTION

    Directory of Open Access Journals (Sweden)

    G. Kowal

    2009-01-01

    Full Text Available We study the e ects of turbulence on magnetic reconnection using three-dimensional numerical simulations.This is the rst attempt to test the model of fast magnetic reconnection proposed by Lazarian & Vishniac (1999, which assumes the presence of weak, small-scale magnetic eld structure near the current sheet. This a ects the rate of reconnection by reducing the transverse scale for reconnection ows and by allowing many independent ux reconnection events to occur simultaneously. We performed a number of simulations to test the dependencies of the reconnection speed, de ned as the ratio of the in ow velocity to the Alfv n speed, on the turbulence power, the injection scale and resistivity. Our results show that turbulence signi cantly a ects the topology of magnetic eld near the di usion region and increases the thickness of the out ow region. We con rm the predictions of the Lazarian & Vishniac model. In particular, we report the growth of the reconnection speed proportional to V 2 l , where Vl is the amplitude of velocity at the injection scale. It depends on the injection scale linj as (linj=L2=3, where L is the size of the system, which is somewhat faster but still roughly consistent with the theoretical expectations. We also show that for 3D reconnection the Ohmic resistivity is important in the local reconnection events only, and the global reconnection rate in the presence of turbulence does not depend on it.

  13. Demountable, High field High-Temperature Superconductor TF coils for flexible steady-state fusion experiments

    Science.gov (United States)

    Michael, Phillip; Bromberg, Leslie; Vieira, Rui; Minervini, Joseph; Galea, Christopher; Hensley, Sarah; Whyte, Dennis

    2014-10-01

    The excellent properties of HTS materials (e.g., YBCO) at high fields and elevated temperatures (>20 K), offer operational advantages for fusion machines, but results in challenges. For fusion devices, the ability to disassemble the TF coil is very attractive as it provides direct access to maintain the vacuum vessel, first wall and other components in a timely manner. High current conductors, made from multiple thin tapes, are not available but are being developed. Quench protection is a serious issue with HTS magnets, and novel means are needed to detect normal zones and to quickly discharge the magnet. Potential cables designs, demountable magnets and solutions to quench and protection issues for an HTS TF magnet for the Vulcan device (long term PMI studies) will be described. We also describe means for making continuous, persistent loops with HTS tapes. These loops offer an alternative to expensive monoliths for field control for complex geometries, such as stellarator-like fields. Partially supported by US DOE DE-FC02-93ER54186.

  14. Neutron scattering studies of modulated magnetic structures

    Energy Technology Data Exchange (ETDEWEB)

    Aagaard Soerensen, Steen

    1999-08-01

    This report describes investigations of the magnetic systems DyFe{sub 4}Al{sub 8} and MnSi by neutron scattering and in the former case also by X-ray magnetic resonant scattering. The report is divided into three parts: An introduction to the technique of neutron scattering with special emphasis on the relation between the scattering cross section and the correlations between the scattering entities of the sample. The theoretical framework of neutron scattering experiments using polarized beam technique is outlined. The second part describes neutron and X-ray scattering investigation of the magnetic structures of DyFe{sub 4}Al{sub 8}. The Fe sublattice of the compound order at 180 K in a cycloidal structure in the basal plane of the bct crystal structure. At 25 K the ordering of the Dy sublattice shows up. By the element specific technique of X-ray resonant magnetic scattering, the basal plane cycloidal structure was also found for the Dy sublattice. The work also includes neutron scattering studies of DyFe{sub 4}Al{sub 8} in magnetic fields up to 5 T applied along a <110> direction. The modulated structure at the Dy sublattice is quenched by a field lower than 1 T, whereas modulation is present at the Fe sublattice even when the 5 T field is applied. In the third part of the report, results from three small angle neutron experiments on MnSi are presented. At ambient pressure, a MnSi is known to form a helical spin density wave at temperature below 29 K. The application of 4.5 kbar pressure intended as hydrostatic decreased the Neel temperature to 25 K and changed the orientation of the modulation vector. To understand this reorientation within the current theoretical framework, anisotropic deformation of the sample crystal must be present. The development of magnetic critical scattering with an isotropic distribution of intensity has been studied at a level of detail higher than that of work found in the literature. Finally the potential of a novel polarization

  15. Direct imaging of rf waveguide modes via ultra-high field NMR

    CERN Document Server

    Tonyushkin, A; Van de Moortele, P -F; Adriany, G; Kiruluta, A

    2016-01-01

    We demonstrate an experimental method for direct 2D and 3D imaging of magnetic rf field distribution in metal waveguides based on traveling wave (TW) nuclear-magnetic resonance (NMR) imaging at ultra-high field (>7T). The typical apparatus would include an ultra-high field whole body or small bore NMR scanner, waveguide elements filled with NMR active dielectrics with predefined electric and magnetic properties, and TW rf transmit-receive probes. We validated the technique by obtaining TW magnetic-resonance (MR) images of the magnetic field distribution of the rf modes of circular waveguide filled with deionized water in a 16.4 T small-bore NMR scanner and compared the MR images with numerical simulations. Our NMR technique opens up a practical way of imaging of previously inaccessible rf field distribution of modes inside of various shapes metal waveguides with inserted dielectric objects, including waveguide mode converters and transformers.

  16. Micromagnetic study of magnetic domain structure and magnetization reversal in amorphous wires with circular anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Betancourt, I., E-mail: israelb@correo.unam.m [Departamento de Materiales Metalicos y Ceramicos, Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Mexico D.F. 04510 (Mexico); Hrkac, G. [Department of Engineering Materials, University of Sheffield, Mappin St., Sheffield S1 3JD (United Kingdom); Schrefl, T. [Department of Engineering Materials, University of Sheffield, Mappin St., Sheffield S1 3JD (United Kingdom); St. Poelten University of Applied Sciences (Austria)

    2011-05-15

    In this work we present a detailed numerical investigation on the magnetic domain formation and magnetization reversal mechanism in sub-millimeter amorphous wires with negative magnetostriction by means of micromagnetic calculations. The formation of circular magnetic domains surrounding a multidomain axially oriented central nucleus was observed for the micromagnetic model representing the amorphous wire. The magnetization reversal explained by micromagnetic computations for the M-H curve is described in terms of a combined nucleation-propagation-rotational mechanism after the saturated state. Results are interpreted in terms of the effective magnetic anisotropy. - Research highlights: > Magnetic domain formation in small amorphous wires is studied by micromagnetic calculations. > Magnetization reversal in small amorphous wires is studied by micromagnetic calculations. > Formation of circular domains around an axially oriented central core was observed. > Magnetization reversal is described in terms of nucleation-propagation-rotational mechanisms. > Magnetic domains and reversal mechanism are consistent with experimental reports.

  17. Stability and quench development study in small HTSC magnet

    NARCIS (Netherlands)

    Ilyin, Yu. A.; Vysotski, V.S.; Kiss, T.; Takeo, M.; Okamoto, H.; Irie, F.

    2001-01-01

    Stability and quench development in a HTSC magnet have been experimentally studied with the transport current in the magnet being below or above the “thermal quench current” level. The magnet was tested at both cryocooler cooling and liquid nitrogen cooling, with and without background magnetic fiel

  18. Stability and quench development study in small HTSC magnet

    NARCIS (Netherlands)

    Ilyin, Y.; Vysotski, V.S.; Kiss, T.; Takeo, M.; Okamoto, H.; Irie, F.

    2001-01-01

    Stability and quench development in a HTSC magnet have been experimentally studied with the transport current in the magnet being below or above the “thermal quench current” level. The magnet was tested at both cryocooler cooling and liquid nitrogen cooling, with and without background magnetic

  19. NMR study of magnetism and superparamagnetism

    Science.gov (United States)

    Yuan, Shaojie

    The research described in this dissertation is concerned with two different types of magnetic materials. Both types of systems involve competing interactions between transition metal ions. New approaches involving magnetic resonance in the large hyperfine fields at nuclear sites have been developed. The interactions responsible for the properties that have been investigated in the materials studied are geometric frustration in an insulator and ferromagnetic and antiferromagnetic interactions in a metal alloy. Further details are given below. The extended kagome frustrated system YBaCo4O7 has 2D kagome and triangular lattices of Co ions stacked along the c-axis. Antiferromagnetic (AF) ordering accompanied by a structural transition has been reported in the literature. From a zero field (ZF) NMR single crystal rotation experiment, we have obtained the Co spin configurations for both the kagome and triangular layers. A 'spin-flop' configuration between the spins on the kagome layer and the spins on the triangular layer is indicated by our results. Our NMR findings are compared with neutron scattering results for this intriguing frustrated AF spin system. The non-stoichiometric oxygenated sister compound YBaCo4O7.1 has application potential for oxygen storage. While, its' magnetic properties are quite different from those of the stoichiometric compound, in spite of their similar structures of alternating kagome and triangular Co layers. Various techniques, including ZF NMR have been used to investigate the spin dynamics and spin configuration in a single crystal of YBaCo4O7.1. A magnetic transition at 80 K is observed, which is interpreted as the freezing out of spins in the triangular layers. At low temperatures (below 50 K), the spin dynamics persists and a fraction of spins in the kagome layers form a viscous spin liquid. Below 10 K, a glass-like spin structure forms and a large distribution of spin correlation times are suggested by nuclear spin lattice relaxation

  20. REVIEW OF HIGH FIELD Q SLOPE, CAVITY MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Gianluigi Ciovati

    2008-01-23

    One of the most interesting phenomenon occurring in superconducting radio-frequency (SRF) cavities made of bulk niobium is represented by a sharp decrease of the quality factor above peak surface magnetic field of about 90 mT and is referred to as "high field Q-slope" or "Q-drop". This phenomenon was observed first in 1997 and since then some effort was devoted to the understanding of the causes behind it. Still, no clear physical interpretation of the Q-drop has emerged, despite several attempts. In this contribution, I will review the experimental results for various cavities measured in many laboratories and I will try to identify common features and differences related to the Q-drop.

  1. Magnetization Reversal Processes in Pt/Co Multilayers Studied by a Magnetic Force Microscope

    Institute of Scientific and Technical Information of China (English)

    张臻蓉; 韩宝善; 刘洪

    2001-01-01

    We have studied the magnetic reversal process of magnetron sputtered Pt/Co multilayers by using a magneticforce microscope with in situ bias magnetic fields. In thin films, magnetic reversal is usually dominated either bydomain nucleation or by domain wall motion. In our experiments, a series of magnetic images in situ capturedin the same area indicates that the magnetic reversal in Pt/Co multilayers is dominated by domain nucleation,instead of domain wall motion. In addition, the. local demagnetized curve was obtained by using the bearinganalysis of the domains in the series of magnetic images.

  2. Magneto-optic studies of magnetic oxides

    Energy Technology Data Exchange (ETDEWEB)

    Gehring, Gillian A., E-mail: g.gehring@shef.ac.uk [Department of Physics and Astronomy, University of Sheffield, Sheffield S3 7RH (United Kingdom); Alshammari, Marzook S.; Score, David S.; Neal, James R.; Mokhtari, Abbas; Fox, A. Mark [Department of Physics and Astronomy, University of Sheffield, Sheffield S3 7RH (United Kingdom)

    2012-10-15

    A brief review of the use of magneto-optic methods to study magnetic oxides is given. A simple method to obtain the magnetic circular dichroism (MCD) of a thin film on a transparent substrate is described. The method takes full account of multiple reflections in the film and substrate. Examples of the magneto-optic spectra of Co-doped ZnO, Fe{sub 3}O{sub 4}, and GdMnO{sub 3} are given. The Maxwell-Garnett method is used to describe the effects of metallic cobalt inclusions in Co:ZnO samples, and the change of the MCD spectra of Fe{sub 3}O{sub 4} at the Verwey temperature is discussed. Data showing different MCD signals at different energies is presented for GdMnO{sub 3}.

  3. Study and Demarcating of Electron Magnetic Spectrometer

    Institute of Scientific and Technical Information of China (English)

    LIYe-jun; SHANYu-sheng; TAOYe-zheng; CHENGYou-jian; ZHANGHai-feng

    2003-01-01

    The principle of electron magnetic spectrometer is a moving charged particle circles a central point for the Lorenz force when it moves in a steady magnetic field, at the same time, we consider the influence of gravity excursion, magnetic grads excursion and curvature excursion. Having adopted yoke iron equalizing technology and had magnetic field and gravity field at the same line.

  4. 高场和超高场MR下人体内B1场均匀性及SAR随场强变化规律的研究%Study on the Law of B1 Field Homogeneity and SAR inside Human Body Varying with Field Strength at High and Ultra-High Field MR

    Institute of Scientific and Technical Information of China (English)

    黄绮华; 高勇; 辛学刚

    2013-01-01

    高场和超高场磁共振成像(MRI)具有高的信噪比,可获得高分辨率的图像,成为磁共振的发展趋势.在磁共振成像系统中,射频线圈产生的射频磁场(B1场)均匀性将直接影响图像质量,且人体组织对射频能量的过多吸收会给受检者带来安全问题,因此研究高场和超高场MR下人体组织B1场均匀性和特定能量吸收率(SAR)随场强变化的关系意义重大.为了准确分析不同场强下人体组织B1场均匀性和SAR值分布,采用时域有限差分法,以真实女性盆腔电磁模型作为磁共振系统中TEN体线圈的负载,在磁通密度为1.5、3、7T下分别对盆腔内部B1场和SAR进行数值计算,比较分析不同场强下人体内部B1场分布均匀性和SAR的变化规律.数值计算结果表明:磁通密度由1.5T分别增加到3和7T时,B1场的均匀性分别降低11.54%和49.97%,盆腔各组织SAR的平均值最大提高4.7和24.14倍,局部最大值最大提高5.5和22倍;而且随着场强增高,人体内深层组织吸收的射频能量显著增加,7T时皮肤、肌肉和组织液的SAR已经超出了安全阈值.可见,B1场均匀性和SAR值随场强增高变化显著,需要根据实际需要对TEM线圈进行优化,以提高成像效果并确保受检者安全.%High and ultra-high field MRI are receiving more concerns in current clinical applications due to substantial enhancement of the signal-to-noise ratio and spatial resolution. The uniformity of B, field directly affects the quality of the image and the RF energy absorbed inside the tissues relates to the safety directly. Therefore, there is a great significance to study on the relationship between magnetic field strength and the B, field uniformity, specific energy absorption rate (SAR) at high and ultra-high field MR. The finite difference time domain (FDTD) was utilized to accurately analyze the performance and safety of high and ultra-high field MR system loaded with the real female pelvis

  5. Study on magnetic field mapping within cylindrical center volume of general magnet

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Li; Lee, Sang Jin [Uiduk University, Gyeongju (Korea, Republic of)

    2016-06-15

    For the magnetic field analysis or design, it is important to know the behavior of the magnetic field in an interesting space. Magnetic field mapping becomes a useful tool for the study of magnetic field. In this paper, a numerical way for mapping the magnetic field within the cylindrical center volume of magnet is presented, based on the solution of the Laplace's equation in the cylindrical coordinate system. The expression of the magnetic field can be obtained by the magnetic flux density, which measured in the mapped volume. According to the form of the expression, the measurement points are arranged with the parallel cylindrical line (PCL) method. As example, the magnetic flux density generated by an electron cyclotron resonance ion source (ECRIS) magnet and a quadrupole magnet were mapped using the PCL method, respectively. The mapping results show the PCL arrangement method is feasible and convenience to map the magnetic field within a cylindrical center volume generated by the general magnet.

  6. Study of the reduced magnetic field required for thermally assisted magnetization reversal

    Science.gov (United States)

    Firdausi, H. F. Y.; Utari; Purnama, B.

    2016-11-01

    The reduced magnetic field required for thermally magnetization reversal discussed in this paper. Study of thermally assisted magnetization reversal conduct by using micromagnetic simulation. The magnetic dot size of the simulation was 50 nm × 50 nm × 20 nm. The perpendicularly anisotropy constant was 2 × 106 erg/cm3. Initial condition was set single domain configuration. Then a sufficiently thermal pulse was used to get stochastic effect so that the magnetization along to the induce field direction for pico second duration. The results show that the reduced magnetic field mechanism seem to be temporary antiferromagnetic configuration before single domain configuration in alinging along to field direction. The same mechanims observed for modify of thickness dot particles. The require magnetic field of 145 Oe in thermally assisted magnetization reversal open a posibility for MRAM application.

  7. A high-field adiabatic fast passage ultracold neutron spin flipper for the UCNA experiment

    Energy Technology Data Exchange (ETDEWEB)

    Holley, A. T.; Pattie, R. W.; Young, A. R. [Department of Physics, North Carolina State University, Raleigh, North Carolina 27695 (United States); Broussard, L. J. [Department of Physics, Duke University, Durham, North Carolina 27708 (United States); Davis, J. L.; Ito, T. M.; Lyles, J. T. M.; Makela, M.; Morris, C. L.; Mortensen, R.; Saunders, A. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Hickerson, K.; Mendenhall, M. P. [W. K. Kellogg Radiation Laboratory, California Institute of Technology, Pasadena, California 91125 (United States); Liu, C.-Y. [Department of Physics, Indiana University, Bloomington, Indiana 47405 (United States); Mammei, R. R. [Department of Physics, Virginia Tech, Blacksburg, Virginia 24061 (United States); Rios, R. [Department of Physics, Idaho State University, Pocatello, Idaho 83209 (United States)

    2012-07-15

    The UCNA collaboration is making a precision measurement of the {beta} asymmetry (A) in free neutron decay using polarized ultracold neutrons (UCN). A critical component of this experiment is an adiabatic fast passage neutron spin flipper capable of efficient operation in ambient magnetic fields on the order of 1 T. The requirement that it operate in a high field necessitated the construction of a free neutron spin flipper based, for the first time, on a birdcage resonator. The design, construction, and initial testing of this spin flipper prior to its use in the first measurement of A with UCN during the 2007 run cycle of the Los Alamos Neutron Science Center's 800 MeV proton accelerator is detailed. These studies determined the flipping efficiency of the device, averaged over the UCN spectrum present at the location of the spin flipper, to be {epsilon}=0.9985(4).

  8. Large field-of-view transmission line resonator for high field MRI

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johannesson, Kristjan Sundgaard; Boer, Vincent

    2016-01-01

    Transmission line resonators is often a preferable choice for coils in high field magnetic resonance imaging (MRI), because they provide a number of advantages over traditional loop coils. The size of such resonators, however, is limited to shorter than half a wavelength due to high standing wave....... Achieved magnetic field distribution is compared to the conventional transmission line resonator. Imaging experiments are performed using 7 Tesla MRI system. The developed resonator is useful for building coils with large field-of-view....

  9. Large field-of-view transmission line resonator for high field MRI

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johannesson, Kristjan Sundgaard; Boer, Vincent;

    2016-01-01

    Transmission line resonators is often a preferable choice for coils in high field magnetic resonance imaging (MRI), because they provide a number of advantages over traditional loop coils. The size of such resonators, however, is limited to shorter than half a wavelength due to high standing wave....... Achieved magnetic field distribution is compared to the conventional transmission line resonator. Imaging experiments are performed using 7 Tesla MRI system. The developed resonator is useful for building coils with large field-of-view....

  10. High-field 3He-F interaction at the surface of fluorocarbon spheres

    DEFF Research Database (Denmark)

    Schuhl, A.; Chapellier, M.; Rasmussen, Finn Berg

    1984-01-01

    High-field experiments on the relaxation betweenF in small Teflon spheres andHe on the surface are reported. WithHe as a monolayer, coupling times are found to be less than 5 sec, in magnetic fields up to 3 T and temperatures down to 50 mK, where electronic centers are completely polarized...

  11. Layered magnets: polarized neutron reflection studies

    Energy Technology Data Exchange (ETDEWEB)

    Zabel, H.; Schreyer, A. [Ruhr-Univ. Bochum, Lehrstuhl fuer Experimentalphysik/Festkoerperphysik, Bochum (Germany)

    1996-11-01

    Neutron reflectivity measurements from extended surfaces, thin films and superlattices provide information on the chemical profile parallel to the film normal, including film thicknesses, average composition and interfacial roughness parameters. Reflectivity measurements with polarized neutrons are particularly powerful for analyzing the magnetic density profiles in thin films and superlattices in addition to chemical profiles. The basic theory of polarized neutron reflectivity is provided, followed by some examples and more recent applications concerning polarized neutron reflectivity studies from exchange coupled Fe/Cr superlattices. (author) 5 figs., 13 refs.

  12. Magnetic resonance spectroscopy studies in migraine

    Energy Technology Data Exchange (ETDEWEB)

    Montagna, P.; Cortelli, P.; Barbiroli, B. (Inst. of Medical Pathology, Univ. of Bologna (Italy))

    1994-06-01

    The authors describe the method of [sup 31]phosphorus magnetic resonance spectroscopy and review the results when it is applied to the study of brain and muscle energy metabolism in migraine subjects. Brain energy metabolism appears to be abnormal in all major subtypes of migraine when measured both during and between attacks. Impaired energy metabolism is also documented in skeletal muscle. It is suggested that migraine is associated with a generalized disorder of mitochondrial oxidative phosphorylation and that this may constitute a threshold for the triggering of migraine attacks. 47 refs., 10 figs., 3 tabs.

  13. The design of a large aperture high field dipole

    Energy Technology Data Exchange (ETDEWEB)

    Harfoush, F.; Harrison, M.; Kerby, J.; Koepke, K.; Mantsch, P.; Nicol, T.; Riddiford, A.; Theilacker, J.

    1989-12-01

    The impetus for this design report originated in the Snowmass 88 meeting where the subject of higher energies within the constraints of the existing Tevatron tunnel enclosure was investigated. It was determined that beam transport to the fixed target experimental areas was possible up to an energy of {approximately}1.5 Tev. Collider operation was feasible at somewhat higher energies (1.8 Tev), primarily limited by the ability to design a single turn beam abort system within the constraints of the straight section length. A new accelerator in the existing tunnel would, of necessity, have a similar though not identical lattice and straight section layout to the present Tevatron. Thus when issues arose in the magnet design requiring input from the accelerator standpoint we have assumed a Tevatron like machine. The possibility of using these high field magnets as elements in the existing Tevatron to create new warm space,' for another Interaction Region for example, also emphasizes compatibility with the present machine. 16 refs., 62 figs., 23 tabs.

  14. Computational Studies of Magnetically Doped Semiconductor Nanoclusters

    Science.gov (United States)

    Gutsev, Lavrenty Gennady

    Spin-polarized unrestricted density functional theory is used to calculate the molecular properties of magnetic semiconductor quantum dots doped with 3d-metal atoms. We calculate total energies of the low spin antiferromagnetically coupled states using a spin-flipping algorithm leading to the broken-symmetry states. Given the novel nature of the materials studied, we simulate experimental observables such as hyperfine couplings, ionization/ energies, electron affinities, first and second order polarizabilities, band gaps and exchange coupling constants. Specifically, we begin our investigation with pure clusters of (CdSe )16 and demonstrate the dependence of molecular observables on geometrical structures. We also show that the many isomers of this cluster are energetically quite closely spaced, and thus it would be necessary to employ a battery of tests to experimentally distinguish them. Next, we discuss Mn-doping into the cage (CdSe)9 cluster as well as the zinc-blende stacking type cluster (CdSe)36. We show that the local exchange coupling mechanism is ligand-mediated superexchange and simulate the isotropic hyperfine constants. Finally, we discuss a novel study where (CdSe)9 is doped with Mn or Fe up to a full replacement of all the Cd's and discuss the transition points for the magnetic behavior and specifically the greatly differing band-gap shifts. We also outline an unexpected pattern in the polarizability of the material as metals are added and compare our results with the results from theoretical studies of the bulk material.

  15. Raman study of magnetic phase transitions of hexagonal manganites

    Science.gov (United States)

    Nam, Ji-Yeon; Hien, Nguyen T. M.; Huyen, Nguyen T.; Han, Kiok; Chen, Xiang-Bai; Cheong, S. W.; Lee, D.; Noh, T. W.; Sung, N. H.; Cho, B. K.; Yang, In-Sang

    2014-03-01

    Results of Raman studies of magnetic phase transitions of hexagonal LuMnO3 single crystal and HoMnO3 thin films are compared directly with the results of magnetic measurements. Our results show that the temperature dependent Raman study of magnon scattering provides a simple and accurate method for investigating magnetic phase transitions, especially in HoMnO3 thin films. In single crystal, our optical method provides results as good as magnetization measurements.

  16. Derivation of the high field semiconductor equations

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, P.S. (Los Alamos National Lab., NM (United States)); Cox, R.W. (Department of Computer Information Science, Indiana University, Purdue University, Indianapolis (USA)); Wagner, B.A. (Arizona Univ., Tucson, AZ (United States). Dept. of Mathematics)

    1991-01-01

    Electron and hole densities evolve in x-z phase space according to Boltzmann equations. When the mean free path of the particles is short and electric force on the particles is weak, a well-known expansion can be used to solve the Boltzmann equation. This asymptotic solution shows that the spatial density of electrons and holes evolves according to diffusion-drift equations. As devices become smaller, electric fields become stronger, which renders the Basic Semiconductor Equations increasingly inaccurate. To remedy this problem, we use singular perturbation techniques to obtain a new asymptotic expansion for the Boltzmann equation. Like the Hilbert expansion, the new expansion requires the mean free path to be short compared to all macroscopic length scales. However, it does not require the electric forces to be weak. The new expansion shows that spatial densities obey diffusion-drift equations as before, but the diffusivity D and mobility {mu} turn out to be nonlinear functions of the electric field. In particular, our analysis determines the field-dependent mobilities {mu}(E) and diffusivities D(E) directly from the scattering operator. By carrying out this asymptotic expansion to higher order, we obtain the high frequency corrections to the drift velocity and diffusivity, and also the corrections due to gradients in the electric field. Remarkably, we find that Einsteins's relation is still satisfied, even with these corrections. The new diffusion-drift equations, together with Poissons' equation for the electric field, form the high-field semiconductor equations, which can be expected to be accurate regardless of the strength of the electric fields within the semiconductor. In addition, our analysis determines the entire momentum distribution of the particles, so we derive a very accurate first moment model for semi-conductors by substituting the asymptotically-correct distribution back into the Boltzmann equation and taking moments.

  17. Molecular structure and motion in zero field magnetic resonance

    Energy Technology Data Exchange (ETDEWEB)

    Jarvie, T.P.

    1989-10-01

    Zero field magnetic resonance is well suited for the determination of molecular structure and the study of motion in disordered materials. Experiments performed in zero applied magnetic field avoid the anisotropic broadening in high field nuclear magnetic resonance (NMR) experiments. As a result, molecular structure and subtle effects of motion are more readily observed.

  18. Threats to ultra-high-field MRI

    Science.gov (United States)

    Le Bihan, Denis

    2009-08-01

    In 2004 the European Commission (EC) adopted a directive restricting occupational exposure to electromagnetic fields. This directive (2004/40/CE), which examines the possible health risks of the electromagnetic fields from mobile phones, Wi-Fi, Bluetooth and other devices, concluded that upper limits on radiation and applied electromagnetic fields are necessary to prevent workers from suffering any undue acute health effects. But although not initially intended, the biggest impact of the directive could be on magnetic resonance imaging (MRI), which is used in hospitals worldwide to produce images of unrivalled quality of the brain and other soft tissues.

  19. Susceptibility Contrast in High Field MRI of Human Brain as a Function of Tissue Iron Content

    Science.gov (United States)

    Yao, Bing; Li, Tie-Qiang; van Gelderen, Peter; Shmueli, Karin; de Zwart, Jacco A.; Duyn, Jeff H.

    2009-01-01

    Magnetic susceptibility provides an important contrast mechanism for MRI. Increasingly, susceptibility-based contrast is being exploited to investigate brain tissue microstructure and to detect abnormal levels of brain iron as these have been implicated in a variety of neuro-degenerative diseases. However, it remains unclear to what extent magnetic susceptibility-related contrast at high field relates to actual brain iron concentrations. In this study, we performed susceptibility weighted imaging as a function of field strength on healthy brains in vivo and post-mortem brain tissues at 1.5T, 3T and 7T. Iron histology was performed on the tissue samples for comparison. The calculated susceptibility-related parameters R2* and signal frequency shift in four iron-rich regions (putamen, globus pallidus, caudate, and thalamus) showed an almost linear dependence (r=0.90 for R2*; r=0.83 for phase, p<0.01) on field strength, suggesting that potential ferritin saturation effects are not relevant to susceptibility-weighted contrast for field strengths up to 7T. The R2* dependence on the putative (literature-based) iron concentration was 0.048 Hz/Tesla/ppm. The histological data from brain samples confirmed the linear dependence of R2* on field strength and showed a slope against iron concentration of 0.0099 Hz/Tesla/ppm dry-weight, which is equivalent to 0.05 Hz/Tesla/ppm wet-weight and closely matched the calculated value in vivo. These results confirm the validity of using susceptibility-weighted contrast as an indicator of iron content in iron-rich brain regions. The absence of saturation effects opens the way to exploit the benefits of MRI at high field strengths for the detection of iron distributions with high sensitivity and resolution. PMID:19027861

  20. Magnetic field studies of massive main sequence stars

    CERN Document Server

    Schoeller, M; Ilyin, I; Kharchenko, N V; Briquet, M; Langer, N; Oskinova, L M

    2011-01-01

    We report on the status of our spectropolarimetric observations of massive stars. During the last years, we have discovered magnetic fields in many objects of the upper main sequence, including Be stars, beta Cephei and Slowly Pulsating B stars, and a dozen O stars. Since the effects of those magnetic fields have been found to be substantial by recent models, we are looking into their impact on stellar rotation, pulsation, stellar winds, and chemical abundances. Accurate studies of the age, environment, and kinematic characteristics of the magnetic stars are also promising to give us new insight into the origin of the magnetic fields. Furthermore, longer time series of magnetic field measurements allow us to observe the temporal variability of the magnetic field and to deduce the stellar rotation period and the magnetic field geometry. Studies of the magnetic field in massive stars are indispensable to understand the conditions controlling the presence of those fields and their implications on the stellar phy...

  1. Design study of the KIRAMS-430 superconducting cyclotron magnet

    Science.gov (United States)

    Kim, Hyun Wook; Kang, Joonsun; Hong, Bong Hwan; Jung, In Su

    2016-07-01

    Design study of superconducting cyclotron magnet for the carbon therapy was performed at the Korea Institute of Radiological and Medical Science (KIRAMS). The name of this project is The Korea Heavy Ion Medical Accelerator (KHIMA) project and a fixed frequency cyclotron with four spiral sector magnet was one of the candidate for the accelerator type. Basic parameters of the cyclotron magnet and its characteristics were studied. The isochronous magnetic field which can guide the 12C6+ ions up to 430 MeV/u was designed and used for the single particle tracking simulation. The isochronous condition of magnetic field was achieved by optimization of sector gap and width along the radius. Operating range of superconducting coil current was calculated and changing of the magnetic field caused by mechanical deformations of yokes was considered. From the result of magnetic field design, structure of the magnet yoke was planned.

  2. Magnetically coupled clusters in aggregated maghemite ferrofluid: Mössbauer and magnetization study

    Energy Technology Data Exchange (ETDEWEB)

    Polikarpov, M., E-mail: polikarpov-imp@mail.ru; Cherepanov, V. [National Research Centre “Kurchatov Institute” (Russian Federation); Chuev, M. [Russian Academy of Sciences, Institute of Physics and Technology (Russian Federation); Gabbasov, R. [National Research Centre “Kurchatov Institute” (Russian Federation); Mischenko, I. [Russian Academy of Sciences, Institute of Physics and Technology (Russian Federation); Panchenko, V. [National Research Centre “Kurchatov Institute” (Russian Federation)

    2016-12-15

    Mössbauer spectroscopy in a weak static magnetic field and measurements of isothermal magnetization loops were used to study the effect of polymer coating of the γ-Fe {sub 2}O{sub 3} nanoparticles on the magnetic properties of concentrated ensembles of such nanoparticles. It was found that the individual coating of the nanoparticles by a ∼ 1 nm layer of the polymer leads to the observable changes in the shapes of the Mössbauer spectra and the magnetization curves of the ensembles. Modeling of the experimental magnetization curves in the classical Langevin model and analysis of the Mössbauer spectra in the generalized multi-level relaxation model revealed that the establishment of interparticle magnetic dipole interactions leads to both a ∼ 30 % increase in the magnetic anisotropy constant and a ∼ 35 % increase in the width of the hysteresis loop.

  3. Magnetically coupled clusters in aggregated maghemite ferrofluid: Mössbauer and magnetization study

    Science.gov (United States)

    Polikarpov, M.; Cherepanov, V.; Chuev, M.; Gabbasov, R.; Mischenko, I.; Panchenko, V.

    2016-12-01

    Mössbauer spectroscopy in a weak static magnetic field and measurements of isothermal magnetization loops were used to study the effect of polymer coating of the γ-Fe 2 O 3 nanoparticles on the magnetic properties of concentrated ensembles of such nanoparticles. It was found that the individual coating of the nanoparticles by a ˜ 1 nm layer of the polymer leads to the observable changes in the shapes of the Mössbauer spectra and the magnetization curves of the ensembles. Modeling of the experimental magnetization curves in the classical Langevin model and analysis of the Mössbauer spectra in the generalized multi-level relaxation model revealed that the establishment of interparticle magnetic dipole interactions leads to both a ˜ 30 % increase in the magnetic anisotropy constant and a ˜ 35 % increase in the width of the hysteresis loop.

  4. Magnetic enzyme reactors for isolation and study of heterogeneous glycoproteins

    Energy Technology Data Exchange (ETDEWEB)

    Korecka, Lucie [Department of Analytical Chemistry, University of Pardubice, Namesti Cs. Legii 565, 532 10 Pardubice (Czech Republic)]. E-mail: lucie.korecka@upce.cz; Jezova, Jana [Department of Analytical Chemistry, University of Pardubice, Namesti Cs. Legii 565, 532 10 Pardubice (Czech Republic); Bilkova, Zuzana [Department of Biological and Biochemical Sciences, University of Pardubice, Namesti Cs. Legii 565, 532 10 Pardubice (Czech Republic); Benes, Milan [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovskeho Namesti 2, 162 06 Prague (Czech Republic); Horak, Daniel [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovskeho Namesti 2, 162 06 Prague (Czech Republic); Hradcova, Olga [Department of Biological and Biochemical Sciences, University of Pardubice, Namesti Cs. Legii 565, 532 10 Pardubice (Czech Republic); Slovakova, Marcela [Department of Biological and Biochemical Sciences, University of Pardubice, Namesti Cs. Legii 565, 532 10 Pardubice (Czech Republic); Laboratoire Physicochimie Curie, UMR 168 CNRS/Institute Curie, Paris Cedex 05 (France); Viovy, Jean-Louis [Laboratoire Physicochimie Curie, UMR 168 CNRS/Institute Curie, Paris Cedex 05 (France)

    2005-05-15

    The newly developed magnetic micro- and nanoparticles with defined hydrophobicity and porosity were used for the preparation of magnetic enzyme reactors. Magnetic particles with immobilized proteolytic enzymes trypsin, chymotrypsin and papain and with enzyme neuraminidase were used to study the structure of heterogeneous glycoproteins. Factors such as the type of carrier, immobilization procedure, operational and storage stability, and experimental conditions were optimized.

  5. Magnetic correlations in oxides: Neutron diffraction and neutron depolarization study

    Indian Academy of Sciences (India)

    S M Yusuf

    2008-10-01

    We have studied magnetic correlations in several oxide materials that belong to colossal magnetoresistive, naturally occurring layered oxide showing low-dimensional magnetic ordering, solid oxide fuel cell interconnect materials, and magnetic nanoparticles using neutron diffraction and neutron depolarization techniques. In this paper, an overview of some of these results is given.

  6. [Gastric magnetic resonance study (methods, semiotics)].

    Science.gov (United States)

    Stashuk, G A

    2003-01-01

    The paper shows the potentialities of gastric study by magnetic resonance imaging (MRI). The methodic aspects of gastric study have been worked out. The MRI-semiotics of the unchanged and tumor-affected wall of the stomach and techniques in examining patients with gastric cancer of various sites are described. Using the developed procedure, MRI was performed in 199 patients, including 154 patients with gastric pathology and 45 control individuals who had no altered gastric wall. Great emphasis is placed on the role of MRI in the diagnosis of endophytic (diffuse) gastric cancer that is of priority value in its morphological structure. MRI was found to play a role in the diagnosis of the spread of a tumorous process both along the walls of the stomach and to its adjacent anatomic structures.

  7. Polarimetric studies of magnetic turbulence with interferometer

    CERN Document Server

    Lee, Hyeseung; Cho, Jungyeon

    2016-01-01

    We study statistical properties of synchrotron polarization emitted from media with magnetohydrodynamic (MHD) turbulence. We use both synthetic and MHD turbulence simulation data for our studies. We obtain the spatial spectrum and its derivative with respect to wavelength of synchrotron polarization arising from both synchrotron radiation and Faraday rotation fluctuations. In particular, we investigate how the spectrum changes with frequency. We find that our simulations agree with the theoretical predication in Lazarian \\& Pogosyan (2016). We conclude that the spectrum of synchrotron polarization and it derivative can be very informative tools to get detailed information about the statistical properties of MHD turbulence from radio observations of diffuse synchrotron polarization. Especially, they are useful to recover the statistics of turbulent magnetic field as well as turbulent density of electrons. We also simulate interferometric observations that incorporate the effects of noise and finite telesco...

  8. Brillouin Light Scattering studies of magnetic thin films and multilayers

    CERN Document Server

    Pugh, P R T

    2000-01-01

    crystal films. The films were grown on GaAs substrates and the BLS data gathered was analysed using derived expressions containing cubic and uniaxial anisotropy terms, the latter being derived here from first principals. 3. A series of FeCo alloy films deposited to thicknesses ranging from 46 A to 1000 A. The parameter of interest was the sample thickness below which the sample magnetization was found to be less that that of the bulk material. The BLS results were analysed using the Damon and Eshbach Surface mode expression. 4. The magnetic properties of an Fe/Cr trilayer wedge as a function of interlayer (Cr) spacer thickness. The transition from Antiferromagnetic to Ferromagnetic coupling was observed as function of Cr spacer thickness. BLS measurements at low and high field were correlated with features of the magnetization curves. 5. A series of 3 Co/Pt multilayers as a function of applied field. The results have yielded magnetization values for the films that are much lower than those of bulk Co. This wa...

  9. High-field bipolar loss measurement apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Thullen, P.; Weldon, D.; Wollan, J.

    1980-01-01

    An apparatus was constructed to measure dissipation in superconducting wire in high alternating fields. The apparatus will be used to make measurements on conductors which must operate in fields up to 7.0 T and rates of field change up to 15 T/s. The magnet for this facility is wound of uninsulated, 15 strand Rutherford cable in which the strand is a 0.812 mm diameter, fully mixed matrix, Cu plus CuNi, multifilament NbTi conductor. The coil is wound in a bath cooled configuration with an overall current density of 7.8 kA/cm/sup 2/. The circuit incorporates a pair of locomotive traction motors as the capacitive circuit element for the bipolar swing. The design, construction and operating characteristics of the field coil and the associated circuitry are described.

  10. Functional magnetic resonance imaging studies of language.

    Science.gov (United States)

    Small, Steven L; Burton, Martha W

    2002-11-01

    Functional neuroimaging of language builds on almost 150 years of study in neurology, psychology, linguistics, anatomy, and physiology. In recent years, there has been an explosion of research using functional imaging technology, especially positron emission tomography (PET) and functional magnetic resonance imaging (fMRI), to understand the relationship between brain mechanisms and language processing. These methods combine high-resolution anatomic images with measures of language-specific brain activity to reveal neural correlates of language processing. This article reviews some of what has been learned about the neuroanatomy of language from these imaging techniques. We first discuss the normal case, organizing the presentation according to the levels of language, encompassing words (lexicon), sound structure (phonemes), and sentences (syntax and semantics). Next, we delve into some unusual language processing circumstances, including second languages and sign languages. Finally, we discuss abnormal language processing, including developmental and acquired dyslexia and aphasia.

  11. Alternative Approach to the Provision of the High-field Dipole for FCC-hh

    CERN Document Server

    AUTHOR|(SzGeCERN)435046

    2015-01-01

    This paper describes a possible approach to reducing the complexity and cost of the high field dipole magnets. In addition the cooling of the winding could be improved in the proposed design, with a consequent reduction in the shielding requirements. The correction of multipoles is also addressed: this feature may impact on the dynamic range of operation of the magnets. Noting that it would be possible to add a small gradient component to the dipole, it is suggested that a (partially) combined function lattice should be considered. The proposals lead to a brief re-appraisal of how best to apply superconductivity to magnets for large accelerators.

  12. Study on Transmission Torque Characteristics of a Surface-Permanent-Magnet-Type Magnetic Gear

    Science.gov (United States)

    Niguchi, Noboru; Hirata, Katsuhiro; Hayakawa, Yuichi

    Magnetic gears have some advantages such as low mechanical loss and maintenance-free operation that are not observed in conventional mechanical gears. In addition, magnetic gears have inherent overload protection. Therefore, magnetic gears are expected to be used in special applications; for example, they can be used in a joint of a humanoid robot. Recently, various types of new magnetic gears have been proposed. Among these new gears, a surface-permanent-magnet-type (SPM-type) magnetic gear employing harmonic magnetic flux has gained attention because of its high transmission torque density, though it has a complex structure with multipole magnets. Some studies on an SPM-type magnetic gear have been carried out, but there are few papers on cogging torque. This paper describes the transmission torque characteristics of an SPM-type magnetic gear. The operating principle and the transmission torque under synchronous operation are formulated in accordance with the gear ratio. High orders of the cogging torque are computed by employing the 3-D finite element method, and the validity of the analysis is verified by carrying out measurements on a prototype. Furthermore, a method for reducing the cogging torque is discussed.

  13. High-field electrical and thermal transport in suspended graphene.

    Science.gov (United States)

    Dorgan, Vincent E; Behnam, Ashkan; Conley, Hiram J; Bolotin, Kirill I; Pop, Eric

    2013-10-09

    We study the intrinsic transport properties of suspended graphene devices at high fields (≥1 V/μm) and high temperatures (≥1000 K). Across 15 samples, we find peak (average) saturation velocity of 3.6 × 10(7) cm/s (1.7 × 10(7) cm/s) and peak (average) thermal conductivity of 530 W m(-1) K(-1) (310 W m(-1) K(-1)) at 1000 K. The saturation velocity is 2-4 times and the thermal conductivity 10-17 times greater than in silicon at such elevated temperatures. However, the thermal conductivity shows a steeper decrease at high temperature than in graphite, consistent with stronger effects of second-order three-phonon scattering. Our analysis of sample-to-sample variation suggests the behavior of "cleaner" devices most closely approaches the intrinsic high-field properties of graphene. This study reveals key features of charge and heat flow in graphene up to device breakdown at ~2230 K in vacuum, highlighting remaining unknowns under extreme operating conditions.

  14. R&D steps of a 12-T common coil dipole magnet for SPPC pre-study

    Science.gov (United States)

    Wang, Chengtao; Zhang, Kai; Xu, Qingjin

    2016-11-01

    IHEP (the Institute of High Energy Physics, Beijing, China) has started the R&D of high field accelerator magnet technology from 2014 for recently proposed CEPC-SppC (Circular Electron Positron Collider, Super proton-proton Collider) project. The conceptual design study of a 20-T dipole magnet is ongoing with the common coil configuration, and a 12-T model magnet will be fabricated in the next two years. A 3-step R&D process has been proposed to realize this 12-T common-coil model magnet: first, a 12-T subscale magnet will be fabricated with Nb3Sn and NbTi superconductors to investigate the fabrication process and characteristics of Nb3Sn coils, then a 12-T subscale magnet will be fabricated with only Nb3Sn superconductors to test the stress management method and quench protection method of Nb3Sn coils; the final step is fabricating the 12-T common-coil dipole magnet with HTS (YBCO) and Nb3Sn superconductors to test the field optimization method of the HTS and Nb3Sn coils. The characteristics of these R&D steps will be introduced in the paper.

  15. Transcranial Magnetic Stimulation Studies in Alzheimer's Disease

    Directory of Open Access Journals (Sweden)

    Andrea Guerra

    2011-01-01

    Full Text Available Although motor deficits affect patients with Alzheimer's disease (AD only at later stages, recent studies demonstrated that primary motor cortex is precociously affected by neuronal degeneration. It is conceivable that neuronal loss is compensated by reorganization of the neural circuitries, thereby maintaining motor performances in daily living. Effectively several transcranial magnetic stimulation (TMS studies have demonstrated that cortical excitability is enhanced in AD and primary motor cortex presents functional reorganization. Although the best hypothesis for the pathogenesis of AD remains the degeneration of cholinergic neurons in specific regions of the basal forebrain, the application of specific TMS protocols pointed out a role of other neurotransmitters. The present paper provides a perspective of the TMS techniques used to study neurophysiological aspects of AD showing also that, based on different patterns of cortical excitability, TMS may be useful in discriminating between physiological and pathological brain aging at least at the group level. Moreover repetitive TMS might become useful in the rehabilitation of AD patients. Finally integrated approaches utilizing TMS together with others neuro-physiological techniques, such as high-density EEG, and structural and functional imaging as well as biological markers are proposed as promising tool for large-scale, low-cost, and noninvasive evaluation of at-risk populations.

  16. Combined neutron and synchrotron studies of magnetic films

    Indian Academy of Sciences (India)

    Sunil K Sinha; S Roy; M R Fitzsimmons; S Park; M Dorn; O Petracic; I V Roshchin; Zhi-Pan Li; X Batlle; R Morales; A Misra; X Zhang; K Chesnel; J B Kortright; Ivan K Schuller

    2006-07-01

    We discuss specular reflectivity and off-specular scattering of neutrons and X-rays from magnetic films. Both these techniques are capable of providing information about the morphology of the chemical and magnetic roughness and the magnetic domain structure. The use of neutrons with polarization analysis enables the spatial distribution of different vector components of the magnetization to be determined, and the use of resonant magnetic X-ray scattering enables magnetization in a compound system to be determined element-selectively. Thus both these methods provide powerful and complementary new probes for studying magnetism at the nanoscopic level in a variety of systems such as those exhibiting exchange bias, giant magnetoresistance, spin injection, etc. We shall illustrate with an example of both techniques applied to an exchange bias system consisting of a single crystal of antiferromagnetic FeF2 capped with a ferromagnetic Co film, and discuss what has been learned about how exchange bias works in such a system.

  17. Fundamental study of phosphor separation by controlling magnetic force

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Kohei, E-mail: kohei@qb.see.eng.osaka-u.ac.jp; Mishima, Fumihito; Akiyama, Yoko, E-mail: yoko-ak@qb.see.eng.osaka-u.ac.jp; Nishijima, Shigehiro

    2013-11-15

    Highlights: •We tried to separate the phosphor using the magnetic Archimedes separation method. •In this method, vertical and radial components of the magnetic force were used. •We succeeded to separate HP and developed the continuous separation system. •The separation system enables successive separation and recovery of HP. -- Abstract: The phosphor wastes consist of phosphors with different emission colors, green (LAP), red (YOX), blue (BAM) and white (HP). It is required to recover and reuse the rare earth phosphors with high market value. In this study, we tried to separate the phosphor using the magnetic separation by HTS bulk magnet utilizing the differences of magnetic susceptibility by the type of phosphors. We succeeded in the successive separation of HP with low market value from YOX and BAM including the rare earth using the magnetic Archimedes method. In this method, vertical and radial components of the magnetic force were used.

  18. Observational Study of Solar Magnetic Active Phenomena

    Indian Academy of Sciences (India)

    Hongqi Zhang

    2006-06-01

    The electric current separated into two parts reflected the quantative properties of heterogeneity and chirality of magnetic field, and defined them as the shear and twist components of current. We analyze the basic configuration and evolution of superactive region NOAA 6580-6619-6659. It is found that the contribution of the twist component of current cannot be reflected in the normal analysis of the magnetic shear and gradient of the active regions. The observational evidence of kink magnetic ropes generated from the subatmosphere cannot be found completely in some super delta active regions.

  19. NUCLEAR MAGNETIC RESONANCE STUDIES OF URANOCENES

    Energy Technology Data Exchange (ETDEWEB)

    Luke, Wayne D.; Streitwieser, Jr., Andrew

    1979-12-01

    In the past several years a substantial amount of work has been devoted toward evaluation of the contact and pseudocontact contributions to the observed isotropic shifts in H nuclear magnetic resonance (NMR) spectra of uranium(IV) organometallic compounds. One reason for interest in this area arises from using the presence of contact shifts as a prcbe for covalent character in the uranium carbon bonds in these compounds. Several extensive {sup 1}H NNR studies on Cp{sub 3} U-X compounds and less extensive studies on uranocenes have been reported. Interpretation of these results suggests that contact shifts-contribute significantly to the observed isotropic shifts. Their presence has been taken as indicative of covalent character of metal carbon bonds in these systems, but agreement is not complete. In this paper we shall review critically the work reported on uranocenes in the light of recent results and report recent work on attempted separation of the observed isotropic shifts in alkyluranocenes into contact and pseudocontact components.

  20. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Koh [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Arthanari, Haribabu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States); Shimada, Ichio, E-mail: shimada@iw-nmr.f.u-tokyo.ac.jp [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Wagner, Gerhard, E-mail: gerhard-wagner@hms.harvard.edu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States)

    2015-12-15

    Detection of {sup 15}N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached {sup 15}N nuclei (TROSY {sup 15}N{sub H}) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow {sup 15}N transverse relaxation and compensating for the inherently low {sup 15}N sensitivity. The {sup 15}N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY {sup 15}N{sub H} component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a {sup 15}N-detected 2D {sup 1}H–{sup 15}N TROSY-HSQC ({sup 15}N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ{sub c} ∼ 40 ns). Unlike for {sup 1}H detected TROSY, deuteration is not mandatory to benefit {sup 15}N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording {sup 15}N TROSY of proteins expressed in H{sub 2}O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D{sub 2}O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of {sup 15}N{sub H}-detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz.

  1. Study on ultra-precision magnetic abrasive finishing process using low frequency alternating magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jinzhong, E-mail: wjz.0926@163.com; Zou, Yanhua, E-mail: yanhua@cc.utsunomiya-u.ac.jp; Sugiyama, Hitoshi, E-mail: sugiyama@cc.utsunomiya-u.ac.jp

    2015-07-15

    We proposed a new ultra-precision magnetic abrasive finishing (MAF) process using low frequency alternating magnetic field in this paper. Magnetic cluster themselves may produce the up and down movement change under alternating magnetic force. The movement may not only promote the dispersion of micro-magnetic particles, but also improve stirring effect and cross-cutting effects of the abrasives, achieving circulation and update to ensure the stability of grinding tools. This process is considered to be able to efficiently apply in ultra-precision finishing of plane and complicated micro-surfaces. In this study, we investigated the effects of alternating magnetic field on magnetic field distribution, finishing force and abrasive behavior. Furthermore, a set of experimental devices have been designed for finishing SUS304 stainless steel plate. The present work is aimed at understanding finishing particularity of this process and studying impacts of important process parameters namely grinding fluid, rotational speed of magnetic pole, current frequency on change in finish surface and material removal. Experimental results indicate that the process can realize ultra-precision finishing of plane by using oily grinding fluid. In the present research, the surface roughness of SUS304 stainless steel plate was improved from 240.24 nm to 4.38 nm by this process. - Highlights: • We investigated magnetic field distribution in processing region. • Magnetic cluster can produce a fluctuating finishing force in alternating magnetic field. • Oily grinding fluid is more applicable to this process. • Few nanometer finish surface can be obtained by this process.

  2. 7.0T功能MR波谱动态定量检测视觉皮层代谢物对视觉刺激的反应%Investigation of the metabolic changes in visual cortex due to visual stimulation using high field magnetic resonance spectroscopy at 7.0 T

    Institute of Scientific and Technical Information of China (English)

    林艳; Morris Peter; 吴仁华

    2012-01-01

    investigate the metabolic changes in the visual cortex due to visual stimulation using high field functional proton magnetic resonance spectroscopy at 7.0 T.A clear picture of brain metabolism and neurotransmitter activity during activation was expected to be established.Methods Nine healthy subjects participated in this study. All MR measurements were acquired using a 7.0 T MR system and a 16-channel SENSE head coil. An initial fMRI scan was performed prior to spectroscopic acquisition in order to determine the activated region in the visual cortex.A cubic ROI of 2 cm× 2 cm × 2 cm was positioned inside the activated region for functional MRS acquisition.A short TE STEAM sequence was used for acquiring the MRS data. The functional paradigm comprised 6.6 min baseline followed by 13.2 min of visual stimulation and 19.8 min recovery.Summed averaged spectra for visual stimulus off and visual stimulus on were analyzed separately using LC Model and internal reference of water. A Wilcoxon signed rank test was conducted to compare the metabolite changes. Results During stimulation,concentration in Asp [ ( 3.20 ± 0.28 ) μmol/g ],Gln [ ( 2.07 ± 0.10 ) μmol/g ] and Gly [ ( 1.65 ± 0.11 )μmol/g ] was found to be significantly decreased,compared with that of ( 3.52 ± 0.28 ),( 2.25 ± 0.10 ) and ( 1.85 ± 0.11 ) μmol/g in rest ( Z =- 2.073,- 2.073 and - 2.429,respectively,P < 0.05 ).The level in Glu [ ( 11.50 ± 0.11 ) μmol/g],GSH[ (2.45 ± 0.10) μmol/g] and Lac[ (0.89 ± 0.05) μ.mol/g]due to neuronal activation was found to be significantly increased,versus resting concentration of ( 11.28 ± 0.11 ),( 2.28 ± 0.10 ) and (0.79 ± 0.05 ) μmol/g,respectively ( Z =2.521,2.310,2.016,respectively,P <0.05).Glc level [ (1.54 ± 0.23 )μmol/g] exhibited a tendency to decrease throughout the period of stimulation,compared with that of [ (1.78 ± 0.28 ) μmol/g ] in rest,but the decrease did not reach statistical significance (Z =- 1.897,P > 0.05 ).Conclusions Using a novel visual

  3. Magnetic nanoparticles studied by small angle X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cristiano Luis Pinto [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica. Grupo de Fluidos Complexos; Antonel, Soledad; Negri, Martin [Universidad de Buenos Aires (UBA) (Argentina). Facultad de Ciencias Exactas y Naturales. Dept. de Quimica Inorganica, Analitica y Quimica Fisica

    2011-07-01

    Full text: Magnetic nanoparticles have attracted much attention in the past decades because of their potential applications in high-density magnetic recording, magnetic fluids, data storage, spin-tronics, solar cells, sensors and catalysis. Among the magnetic nanoparticles, cobalt ferrite (CoFe{sub 2}O{sub 4}) has been widely studied due to high electromagnetic performance, excellent chemical stability, mechanical hardness, and high cubic magnetocrystalline anisotropy. These properties make it a promising candidate for many applications in commercial electronics such as video, audio tapes, high-density digital recording media, and magnetic fluids. Other interesting application is the use of magnetic nanocompounds in the design of magneto elastomers. Magnetoelastomers are dispersions of magnetic particles into an elastomer polymer matrix. These materials are highly promising for applications in the development of sensors and actuators, mainly because of the possibility to optimize the quality parameters of the devices by systematically changing the chemical nature of both the inorganic particles and the organic polymeric matrix, with the consequent modification of the magnetic, electric and elastic properties. Moreover, nanoparticles of cobalt-iron oxides (cobalt ferrite, CoFe{sub 2}O{sub 4}) appears as very interesting compounds for magnetoelasticity, not only because present magnetic anisotropy, moderate-high magnetization and high coercitivity at room temperature, but also because the possibility to modulate its magnetic properties by chemical synthesis, that is by synthesizing nanoparticles of different sizes having thus not only different magnetic parameters but also different magnetic behavior (superparamagnetism or ferromagnetism). That means that most of the magnetic properties of CoFe{sub 2}O{sub 4} ferrite strongly depend on the size and shape of the nanoparticles, which are closely related to the method of preparation. On the other hand, nickel

  4. Design of Nb3Sn magnetic devices to study the superconductor degradation under variable mechanical load

    CERN Document Server

    Regis, Federico

    2009-01-01

    The Large Hadron Collider (LHC) is a two-ring, superconducting synchrotron accelerator and collider installed in a 27 km long tunnel aiming at the discovery of the Higgs particle and the study of rare events with center mass collision energies of up to 14 TeV. The number of collisions per unit of area and time in a collider are evaluated trough the Luminosity function. Inside the LHC, superconducting magnets aligned with a precision of a few tenths of millimeters are used to bend and focus the particle trajectories. The LHC can be considered as the state of the art for superconducting magnets using the Nb-Ti superconductor technology. Therefore, a higher luminosity and beam energy can be achieved in the LHC only by using a more performing superconductor, such as the Nb3Sn. This is considered as the most suitable superconductor to be used in high field magnets, allowing peak field of the order of 15 T. Nevertheless, the critical current jc variations in a Nb3Sn has been found as strongly dependent on the mecha...

  5. NMR magnet technology at MIT

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J.E.C.; Bobrov, E.S.; Iwasa, Y.; Punchard, W.F.B.; Wrenn, J.; Zhukovsky, A. (Massachusetts Inst. of Tech., Cambridge, MA (United States). Francis Bitter National Magnet Lab.)

    1992-01-01

    The design and construction of high field superconducting NMR magnets has much in common with other types of adiabatic superconducting magnets. However, two issues have a particular relevance to NMR magnets. They are field drift and homogeneity. In this paper the control of these factors in the particular context of high field NMR spectrometer magnets is examined.

  6. Magnetic alignment study of rare-earth-containing liquid crystals.

    Science.gov (United States)

    Galyametdinov, Yury G; Haase, Wolfgang; Goderis, Bart; Moors, Dries; Driesen, Kris; Van Deun, Rik; Binnemans, Koen

    2007-12-20

    The liquid-crystalline rare-earth complexes of the type [Ln(LH)3(DOS)3]-where Ln is Tb, Dy, Ho, Er, Tm, or Yb; LH is the Schiff base N-octadecyl-4-tetradecyloxysalicylaldimine; and DOS is dodecylsulfate-exhibit a smectic A phase. Because of the presence of rare-earth ions with a large magnetic anisotropy, the smectic A phase of these liquid crystals can be easier aligned in an external magnetic field than smectic A phases of conventional liquid crystals. The magnetic anisotropy of the [Ln(LH)3(DOS)3] complexes was determined by measurement of the temperature-dependence of the magnetic susceptibility using a Faraday balance. The highest value for the magnetic anisotropy was found for the dysprosium(III) complex. The magnetic alignment of these liquid crystals was studied by time-resolved synchrotron small-angle X-ray scattering experiments. Depending on the sign of the magnetic anisotropy, the director of the liquid-crystalline molecules was aligned parallel or perpendicular to the magnetic field lines. A positive value of the magnetic anisotropy (and parallel alignment) was found for the thulium(III) and the ytterbium(III) complexes, whereas a negative value of the magnetic anisotropy (and perpendicular alignment) was observed for the terbium(III) and dysprosium(III) complexes.

  7. Analysis of magnetic gradients to study gravitropism.

    Science.gov (United States)

    Hasenstein, Karl H; John, Susan; Scherp, Peter; Povinelli, Daniel; Mopper, Susan

    2013-01-01

    Gravitropism typically is generated by dense particles that respond to gravity. Experimental stimulation by high-gradient magnetic fields provides a new approach to selectively manipulate the gravisensing system. The movement of corn, wheat, and potato starch grains in suspension was examined with videomicroscopy during parabolic flights that generated 20 to 25 s of weightlessness. During weightlessness, a magnetic gradient was generated by inserting a wedge into a uniform, external magnetic field that caused repulsion of starch grains. The resultant velocity of movement was compared with the velocity of sedimentation under 1 g conditions. The high-gradient magnetic fields repelled the starch grains and generated a force of at least 0.6 g. Different wedge shapes significantly affected starch velocity and directionality of movement. Magnetic gradients are able to move diamagnetic compounds under weightless or microgravity conditions and serve as directional stimulus during seed germination in low-gravity environments. Further work can determine whether gravity sensing is based on force or contact between amyloplasts and statocyte membrane system.

  8. Chiral Magnetism in an Itinerant Helical Magnet, MnSi - An Extended 29Si NMR Study

    Science.gov (United States)

    Yasuoka, Hiroshi; Motoya, Kiyoichiro; Majumder, Mayukh; Witt, Sebastian; Krellner, Cornelius; Baenitz, Michael

    2016-07-01

    The microscopic magnetism in the helical, conical and ferromagnetically polarized phases in an itinerant helical magnet, MnSi, has been studied by an extended 29Si NMR at zero field and under external magnetic fields. The temperature dependence of the staggered moment, MQ(T), determined by the 29Si NMR frequency, ν(T), and the nuclear relaxation rate, 1/T1(T), at zero field is in general accord with the SCR theory for weak itinerant ferromagnetic metals and its extension to helical magnets. The external field dependence of resonance frequency, ν(H), follows a vector sum of the contributions from the atomic hyperfine and macroscopic fields with a field induced moment characteristic to itinerant magnets. A discontinuous jump of the resonance frequency at the critical field, Hc, between the conical and the polarized phases has also been found, which suggests a first order like change of the electronic states at Hc.

  9. Design Study: ELENA Bending Magnet Prototype

    CERN Document Server

    Schoerling, D

    2013-01-01

    The ELENA bending magnet prototype shall prove that the proposed design meets the requirements set by the ELENA beam dynamics. The following points will be discussed in detail: (i) production process of a magnetic yoke diluted with stainless steel plates, (ii) the stability and repeatability of the field homogeneity of such a yoke over the full working range, (iii) choice of soft magnetic steel, (iv) hysteresis effects, (v) mechanical deformations, (vi) thermal insulation to intercept heat load from baking for activation of NEG coating in the vacuum chamber, (vii) end shim design. In order to verify these points the following measurements will be performed: (i) Hall probe scanning, (ii) integrated field homogeneity measurement (DC), (iii) integrated field homogeneity measurement (AC).

  10. Quench Heater Studies for the LHC Magnets

    CERN Document Server

    Rodríguez-Mateos, F

    2001-01-01

    About 2000 LHC (CERN's Large Hadron Collider) superconducting magnets will be protected with quench heaters against development of excessive voltage and overheating after a resistive transition. The quench heater strips are powered by capacitor bank discharge power supplies. The strips are made of stainless steel partially plated with copper to reduce their resistance and to allow for the connection of quench heaters in series. The strips are embedded in between two polyimide foils. The initial power density and the current decay time determine the quench heater effectiveness. Since only one type of heater power supply will be available, the copper plating cycle is adapted for the various magnet types to keep the resistance of the heater circuit constant. Different quench heater designs have been tested on various prototype magnets to optimise the copper-plating cycle and the electric insulation of the heater strip. This paper summarises the experimental results and computations that allowed to finalise the h...

  11. Magnetic investigations for studying planetary interiors

    Directory of Open Access Journals (Sweden)

    A. De Santis

    1994-06-01

    Full Text Available Most of the magnetic methods used for investigating planetary interiors are based on the reasonable hypothesis that the mechanism for the origin of the field is an Earth-like hydromagnetic dynamo: in this case the planet has an electrically conducting fluid shell within it as in the case of the Earth's core. The present paper describes several techniques of planetary magnetic investigation which give important clues on the internal constitution of planets. Some considerations on the possible mechanisms for maintaining a dynamo and simple concepts with the help of a few non-dimensional numbers are also introduced and discussed. Then some fundamental relationships are given in order to relate the planetary magnetism to other physical parameters, such as angular rotation, core dimensions etc. It finally summarizes some results available for the planets of the Solar System.

  12. Thermo-magnetic instabilities in Nb3Sn superconducting accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Bordini, Bernardo [Univ. of Pisa (Italy)

    2006-09-01

    The advance of High Energy Physics research using circulating accelerators strongly depends on increasing the magnetic bending field which accelerator magnets provide. To achieve high fields, the most powerful present-day accelerator magnets employ NbTi superconducting technology; however, with the start up of Large Hadron Collider (LHC) in 2007, NbTi magnets will have reached the maximum field allowed by the intrinsic properties of this superconductor. A further increase of the field strength necessarily requires a change in superconductor material; the best candidate is Nb3Sn. Several laboratories in the US and Europe are currently working on developing Nb3Sn accelerator magnets, and although these magnets have great potential, it is suspected that their performance may be fundamentally limited by conductor thermo-magnetic instabilities: an idea first proposed by the Fermilab High Field Magnet group early in 2003. This thesis presents a study of thermo-magnetic instability in high field Nb3Sn accelerator magnets. In this chapter the following topics are described: the role of superconducting magnets in High Energy Physics; the main characteristics of superconductors for accelerator magnets; typical measurements of current capability in superconducting strands; the properties of Nb3Sn; a description of the manufacturing process of Nb3Sn strands; superconducting cables; a typical layout of superconducting accelerator magnets; the current state of the art of Nb3Sn accelerator magnets; the High Field Magnet program at Fermilab; and the scope of the thesis.

  13. Complex Magnetic Systems Studied with Neutron Scattering

    DEFF Research Database (Denmark)

    Jacobsen, Henrik

    analytically and compared with neutron scattering experiments on 8 nm and 16 nm particles, validating the theory and determining the magnitude of the anisotropy constants. In addition, the temperature dependence of the excitations and of the superparamagnetism are explored using numerical simulations. Through...... dynamics of GAG as function of applied magnetic eld were measured using inelastic neutron scattering. The data showed the existence of a low energy mode in zero eld, similar to what was discovered in GGG earlier. An applied magnetic eld was found to sharpen the excitations, nally inducing a gap when...

  14. Proceedings of the sixth Japan--US workshop on high-field superconducting materials and standard procedures for high-field superconducting materials testing

    Energy Technology Data Exchange (ETDEWEB)

    Tachikawa, K. (ed.) (Tokai Univ., Kanagawa (Japan). Faculty of Engineering); Yamafuji, K. (ed.) (Kyushu Univ., Fukuoka (Japan). Dept. of Electronics); Wada, H. (ed.) (National Research Inst. for Metals, Tsukuba, Ibaraki (Japan)); Ekin, J.W. (ed.) (National Inst. of Standards and Technology, Boulder, CO (United States)); Suenaga, M. (ed.) (Brookhaven National Lab., Upton, NY (United States))

    1989-01-01

    High critical current densities and high magnetic fields are needed for most important energy application of both conventional and high-Tc superconductors. This workshop brought together those engaged research on high-field superconductors in Japan and the US to present recent research results on performance of new high-field superconducting materials and to discuss the most promising directions for research, specifically as it relates to the fusion energy needs of both countries. Topics covered included critical currents, irradiation effects, ac losses, magnetization properties, and new fabrication processes for conventional superconductors. An entire session was devoted to presentations on the properties of Nb[sub 3]Al superconductors. Large magnet research programs for energy applications were reviewed, including the tokamak fusion machine at JAERI, the joint US-Japan Nb[sub 3]Sn poloidal-field-coll development program, and the proposed International Thermonuclear Experimental Reactor (ITER) project. Results were also presented on the VAMAS round robin in three areas; J[sub c], stress effects, and ac losses. Finally, some current research results on experimental high-[Tc] superconductors were reviewed, with particular emphasis on new fabrication processes and the factors limiting the critical current in high-current conductors. Separate abstracts have been prepared.

  15. Proceedings of the sixth Japan--US workshop on high-field superconducting materials and standard procedures for high-field superconducting materials testing

    Energy Technology Data Exchange (ETDEWEB)

    Tachikawa, K. [ed.] [Tokai Univ., Kanagawa (Japan). Faculty of Engineering; Yamafuji, K. [ed.] [Kyushu Univ., Fukuoka (Japan). Dept. of Electronics; Wada, H. [ed.] [National Research Inst. for Metals, Tsukuba, Ibaraki (Japan); Ekin, J.W. [ed.] [National Inst. of Standards and Technology, Boulder, CO (United States); Suenaga, M. [ed.] [Brookhaven National Lab., Upton, NY (United States)

    1989-12-31

    High critical current densities and high magnetic fields are needed for most important energy application of both conventional and high-Tc superconductors. This workshop brought together those engaged research on high-field superconductors in Japan and the US to present recent research results on performance of new high-field superconducting materials and to discuss the most promising directions for research, specifically as it relates to the fusion energy needs of both countries. Topics covered included critical currents, irradiation effects, ac losses, magnetization properties, and new fabrication processes for conventional superconductors. An entire session was devoted to presentations on the properties of Nb{sub 3}Al superconductors. Large magnet research programs for energy applications were reviewed, including the tokamak fusion machine at JAERI, the joint US-Japan Nb{sub 3}Sn poloidal-field-coll development program, and the proposed International Thermonuclear Experimental Reactor (ITER) project. Results were also presented on the VAMAS round robin in three areas; J{sub c}, stress effects, and ac losses. Finally, some current research results on experimental high-{Tc} superconductors were reviewed, with particular emphasis on new fabrication processes and the factors limiting the critical current in high-current conductors. Separate abstracts have been prepared.

  16. Apparatus and method for magnetically processing a specimen

    Science.gov (United States)

    Ludtka, Gerard M; Ludtka, Gail M; Wilgen, John B; Kisner, Roger A; Jaramillo, Roger A

    2013-09-03

    An apparatus for magnetically processing a specimen that couples high field strength magnetic fields with the magnetocaloric effect includes a high field strength magnet capable of generating a magnetic field of at least 1 Tesla and a magnetocaloric insert disposed within a bore of the high field strength magnet. A method for magnetically processing a specimen includes positioning a specimen adjacent to a magnetocaloric insert within a bore of a magnet and applying a high field strength magnetic field of at least 1 Tesla to the specimen and to the magnetocaloric insert. The temperature of the specimen changes during the application of the high field strength magnetic field due to the magnetocaloric effect.

  17. Apparatus and method for magnetically processing a specimen

    Energy Technology Data Exchange (ETDEWEB)

    Ludtka, Gerard M; Ludtka, Gail M; Wilgen, John B; Kisner, Roger A; Jaramillo, Roger A

    2013-09-03

    An apparatus for magnetically processing a specimen that couples high field strength magnetic fields with the magnetocaloric effect includes a high field strength magnet capable of generating a magnetic field of at least 1 Tesla and a magnetocaloric insert disposed within a bore of the high field strength magnet. A method for magnetically processing a specimen includes positioning a specimen adjacent to a magnetocaloric insert within a bore of a magnet and applying a high field strength magnetic field of at least 1 Tesla to the specimen and to the magnetocaloric insert. The temperature of the specimen changes during the application of the high field strength magnetic field due to the magnetocaloric effect.

  18. X-ray powder diffraction camera for high-field experiments

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, K; Mitsui, Y; Takahashi, K; Watanabe, K [High Field Laboratory for Superconducting Materials, Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)], E-mail: kkoyama@imr.tohoku.ac.jp

    2009-03-01

    We have designed a high-field X-ray diffraction (HF-XRD) camera which will be inserted into an experimental room temperature bore (100 mm) of a conventional solenoid-type cryocooled superconducting magnet (10T-CSM). Using the prototype camera that is same size of the HF-XRD camera, a XRD pattern of Si is taken at room temperature in a zero magnetic field. From the obtained results, the expected ability of the designed HF-XRD camera is presented.

  19. Whole-globe biomechanics using high-field MRI.

    Science.gov (United States)

    Voorhees, Andrew P; Ho, Leon C; Jan, Ning-Jiun; Tran, Huong; van der Merwe, Yolandi; Chan, Kevin; Sigal, Ian A

    2017-07-01

    The eye is a complex structure composed of several interconnected tissues acting together, across the whole globe, to resist deformation due to intraocular pressure (IOP). However, most work in the ocular biomechanics field only examines the response to IOP over smaller regions of the eye. We used high-field MRI to measure IOP induced ocular displacements and deformations over the whole globe. Seven sheep eyes were obtained from a local abattoir and imaged within 48 h using MRI at multiple levels of IOP. IOP was controlled with a gravity perfusion system and a cannula inserted into the anterior chamber. T2-weighted imaging was performed to the eyes serially at 0 mmHg, 10 mmHg, 20 mmHg and 40 mmHg of IOP using a 9.4 T MRI scanner. Manual morphometry was conducted using 3D visualization software to quantify IOP-induced effects at the globe scale (e.g. axial length and equatorial diameters) or optic nerve head scale (e.g. canal diameter, peripapillary sclera bowing). Measurement sensitivity analysis was conducted to determine measurement precision. High-field MRI revealed an outward bowing of the posterior sclera and anterior bulging of the cornea due to IOP elevation. Increments in IOP from 10 to 40 mmHg caused measurable increases in axial length in 6 of 7 eyes of 7.9 ± 5.7% (mean ± SD). Changes in equatorial diameter were minimal, 0.4 ± 1.2% between 10 and 40 mmHg, and in all cases less than the measurement sensitivity. The effects were nonlinear, with larger deformations at normal IOPs (10-20 mmHg) than at elevated IOPs (20-40 mmHg). IOP also caused measurable increases in the nasal-temporal scleral canal diameter of 13.4 ± 9.7% between 0 and 20 mmHg, but not in the superior-inferior diameter. This study demonstrates that high-field MRI can be used to visualize and measure simultaneously the effects of IOP over the whole globe, including the effects on axial length and equatorial diameter, posterior sclera displacement and bowing, and even

  20. Geostatistical Microscale Study of Magnetic Susceptibility in Soil Profile and Magnetic Indicators of Potential Soil Pollution.

    Science.gov (United States)

    Zawadzki, Jarosław; Fabijańczyk, Piotr; Magiera, Tadeusz; Rachwał, Marzena

    Directional variograms, along the soil profile, can be useful and precise tool that can be used to increase the precision of the assessment of soil pollution. The detail analysis of spatial variability in the soil profile can be also an important part of the standardization of soil magnetometry as a screening method for an assessment of soil pollution related to the dust deposition. The goal of this study was to investigate the correlation between basic parameters of spatial correlations of magnetic susceptibility in the soil profile, such as a range of correlation and a sill, and selected magnetometric indicators of soil pollution. Magnetic indicators were an area under the curve of magnetic susceptibility versus a depth in the soil profile, values of magnetic susceptibility at depths ranging from 1 to 10 cm, and maximum and background values of magnetic susceptibility in the soil profile. These indicators were previously analyzed in the literature. The results showed that a range of correlation of magnetic susceptibility was significantly correlated with magnetic susceptibility measured at depths 1, 2, and 3 cm. It suggests that a range of correlation is a good measure of pollutants' dispersion in the soil profile. The sill of the variogram of magnetic susceptibility was found to be significantly correlated with the area under the curve of plot of magnetic susceptibility that is related to the soil pollution. In consequence, the parameters of microscale spatial variability of magnetic susceptibility in s soil profile are important measures that take into consideration the spatial aspect of s soil pollution.

  1. Non-orthogonal approaches to the study of magnetic interactions

    NARCIS (Netherlands)

    Broer-Braam, H.B.; Hozoi, L; Nieuwpoort, WC

    2003-01-01

    Early theoretical studies of magnetic interactions between paramagnetic centres in solids and molecules are briefly reviewed as an introduction to the main theme of this paper: nonorthogonal CI approaches for the prediction and interpretation of magnetic couplings. In a non-orthogonal CI approach, t

  2. Magnetic excitations studied with time-of-flight spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Rainford, B. [Southampton Univ. (United Kingdom). Dept. of Physics

    1996-11-01

    An introduction to time-of-flight neutron spectroscopy is presented in the context of the study of magnetic materials. Examples are taken from the class of rare earth and actinide magnetic materials known as `strongly correlated electron` systems. (author) 11 figs., 24 refs.

  3. In vitro study of magnetic nanoparticles as the implant for implant assisted magnetic drug targeting

    Energy Technology Data Exchange (ETDEWEB)

    Mangual, Jan O.; Aviles, Misael O.; Ebner, Armin D. [Department of Chemical Engineering, University of South Carolina, Columbia, SC 29208 (United States); Ritter, James A., E-mail: ritter@cec.sc.ed [Department of Chemical Engineering, University of South Carolina, Columbia, SC 29208 (United States)

    2011-07-15

    Magnetic nanoparticle (MNP) seeds were studied in vitro for use as an implant in implant assisted-magnetic drug targeting (IA-MDT). The magnetite seeds were captured in a porous polymer, mimicking capillary tissue, with an external magnetic field (70 mT) and then used subsequently to capture magnetic drug carrier particles (MDCPs) (0.87 {mu}m diameter) with the same magnetic field. The effects of the MNP seed diameter (10, 50 and 100 nm), MNP seed concentration (0.25-2.0 mg/mL), and fluid velocity (0.03-0.15 cm/s) on the capture efficiency (CE) of both the MNP seeds and the MDCPs were studied. The CE of the 10 nm MNP seeds was never more than 30%, while those of the 50 and 100 nm MNP seeds was always greater than 80% and in many cases exceeded 90%. Only the MNP seed concentration affected its CE. The 10 nm MNP seeds did not increase the MDCP CE over that obtained in the absence of the MNP seeds, while the 50 and 100 nm MNP seeds increased significantly, typically by more than a factor of two. The 50 and 100 nm MNP seeds also exhibited similar abilities to capture the MDCPs, with the MDCP CE always increasing with decreasing fluid velocity and generally increasing with increasing MNP seed concentration. The MNP seed size, magnetic properties, and capacity to self-agglomerate and form clusters were key properties that make them a viable implant in IA-MDT. - Highlights: 50-100 nm magnetite nanoparticles can be retained in a porous scaffold using a 70 mT field. Their presence improves the collection efficiency of 0.87 {mu}m magnetic drug carrier particles. Magnetic nanoparticles can thus be used as the implant in implant assisted-magnetic drug targeting.

  4. High-Field MRI and Mercury Release from Dental Amalgam Fillings

    Directory of Open Access Journals (Sweden)

    SMJ Mortazavi

    2014-04-01

    Full Text Available Mercury is among the most toxic nonradioactive elements which may cause toxicity even at low doses. Some studies showed release of mercury from dental amalgam fillings in individuals who used mobile phone. This study was conducted to assess the effect of high-field MRI on mercury release from dental amalgam filling. We studied two groups of students with identical tooth decays requiring a similar pattern of restorative dentistry. They were exposed to a magnetic flux density of 1.5 T produced by a MRI machine. 16 otherwise healthy students with identical dental decay participated in this study. They underwent similar restorative dentistry procedures and randomly divided into two groups of MRI-exposed and control arms. Urinary concentrations of mercury in the control subjects were measured before (hour 0 and 48 and 72 hrs after amalgam restoration, using cold vapor atomic absorption spectrometry. Urinary concentrations of mercury in exposed individuals were determined before (hour 0, and 24, 48, 72 and 96 hrs after amalgam restoration. Unlike control subjects, they underwent conventional brain MRI (15 min, 99 slices, 24 hrs after amalgam restoration. The mean±SD urinary mercury levels in MRI-exposed individuals increased linearly from a baseline value of 20.70±17.96 to 24.83±22.91 μg/L 72 hrs after MRI. In the control group, the concentration decreased linearly from 20.70±19.77 to 16.14±20.05 μg/L. The difference between urinary mercury in the exposed and control group, 72 hrs after MRI (96 h after restoration,was significant (p=0.046. These findings provide further support for the noxious effect of MRI (exposure to strong magnetic fieldand release of mercury from dental amalgam fillings.

  5. High-field MRI and mercury release from dental amalgam fillings.

    Science.gov (United States)

    Mortazavi, S M J; Neghab, M; Anoosheh, S M H; Bahaeddini, N; Mortazavi, G; Neghab, P; Rajaeifard, A

    2014-04-01

    Mercury is among the most toxic nonradioactive elements which may cause toxicity even at low doses. Some studies showed release of mercury from dental amalgam fillings in individuals who used mobile phone. This study was conducted to assess the effect of high-field MRI on mercury release from dental amalgam filling. We studied two groups of students with identical tooth decays requiring a similar pattern of restorative dentistry. They were exposed to a magnetic flux density of 1.5 T produced by a MRI machine. 16 otherwise healthy students with identical dental decay participated in this study. They underwent similar restorative dentistry procedures and randomly divided into two groups of MRI-exposed and control arms. Urinary concentrations of mercury in the control subjects were measured before (hour 0) and 48 and 72 hrs after amalgam restoration, using cold vapor atomic absorption spectrometry. Urinary concentrations of mercury in exposed individuals were determined before (hour 0), and 24, 48, 72 and 96 hrs after amalgam restoration. Unlike control subjects, they underwent conventional brain MRI (15 min, 99 slices), 24 hrs after amalgam restoration. The mean±SD urinary mercury levels in MRI-exposed individuals increased linearly from a baseline value of 20.70±17.96 to 24.83±22.91 μg/L 72 hrs after MRI. In the control group, the concentration decreased linearly from 20.70±19.77 to 16.14±20.05 μg/L. The difference between urinary mercury in the exposed and control group, 72 hrs after MRI (96 h after restoration),was significant (p=0.046). These findings provide further support for the noxious effect of MRI (exposure to strong magnetic field)and release of mercury from dental amalgam fillings.

  6. Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationale

    Science.gov (United States)

    Bird, Mark D.; Frydman, Lucio; Long, Joanna R.; Mareci, Thomas H.; Rooney, William D.; Rosen, Bruce; Schenck, John F.; Schepkin, Victor D.; Sherry, A. Dean; Sodickson, Daniel K.; Springer, Charles S.; Thulborn, Keith R.; Uğurbil, Kamil; Wald, Lawrence L.

    2017-01-01

    An initiative to design and build magnetic resonance imaging (MRI) and spectroscopy (MRS) instruments at 14 T and beyond to 20 T has been underway since 2012. This initiative has been supported by 22 interested participants from the USA and Europe, of which 15 are authors of this review. Advances in high temperature superconductor materials, advances in cryocooling engineering, prospects for non-persistent mode stable magnets, and experiences gained from large-bore, high-field magnet engineering for the nuclear fusion endeavors support the feasibility of a human brain MRI and MRS system with 1 ppm homogeneity over at least a 16-cm diameter volume and a bore size of 68 cm. Twelve neuroscience opportunities are presented as well as an analysis of the biophysical and physiological effects to be investigated before exposing human subjects to the high fields of 14 T and beyond. PMID:27194154

  7. Ab initio study of ZnCoO diluted magnetic semiconductor and its magnetic properties

    Energy Technology Data Exchange (ETDEWEB)

    Lardjane, S., E-mail: soumia.lardjane@utbm.fr [Laboratoire d' Etudes et de Recherches, les Procedes et les Surfaces, IRTES-LERMPS, UTBM, Site de Montbeliard, 90010 Belfort Cedex (France); Laboratoire d' Etude et Prediction des Materiaux, Unite de Recherche Materiaux et Energies Renouvelables, LEPM-URMER, Universite de Tlemcen (Algeria); Merad, G. [Laboratoire d' Etude et Prediction des Materiaux, Unite de Recherche Materiaux et Energies Renouvelables, LEPM-URMER, Universite de Tlemcen (Algeria); Fenineche, N.; Billard, A. [Laboratoire d' Etudes et de Recherches, les Procedes et les Surfaces, IRTES-LERMPS, UTBM, Site de Montbeliard, 90010 Belfort Cedex (France); Faraoun, H.I. [Laboratoire d' Etude et Prediction des Materiaux, Unite de Recherche Materiaux et Energies Renouvelables, LEPM-URMER, Universite de Tlemcen (Algeria)

    2013-02-25

    Highlights: Black-Right-Pointing-Pointer We have studied the electronic and magnetic properties of ZnCoO using the GGA and GGA + U. Black-Right-Pointing-Pointer The GGA + U calculations show that the ZnCoO system shows semiconductor band structures. Black-Right-Pointing-Pointer The obtained magnetic moment on Co is larger in the GGA + U case. Black-Right-Pointing-Pointer Antiferromagnetic order between nearest-neighbour magnetic ions was predicted. Black-Right-Pointing-Pointer Our results suggest that the range of magnetic interaction is short in ZnCoO. - Abstract: Transition metal-doped wide band gap semiconductors, such as ZnO, attract much attention due to the theoretical prediction that ZnO is a room temperature ferromagnetic semiconductor [1,2]. Very controversial experimental and theoretical papers have been published to discuss the origin of ferromagnetic ordering and the relevance of the Curie temperature (T{sub C}) of Co-doped ZnO [3-5]. In order to get better insight, electronic structure of Co{sub x}Zn{sub 1-x}O magnetic semiconductor was investigated via first principle calculations. The generalised gradient approximations (GGA) and the GGA with Hubbard U correction (GGA + U) in the framework of density functional theory (DFT) have been used. Calculations are done for different doping concentrations to discuss the contribution of different atoms in magnetic moments and magnetic coupling.

  8. Complex Magnetic Systems Studied with Neutron Scattering

    DEFF Research Database (Denmark)

    Jacobsen, Henrik

    of the lack of conventional long range order in GGG. Several members of the La2􀀀xSrxCuO4+y cuprate family of high-temperature superconductors were investigated using neutron scattering. In La2􀀀xSrxCuO4 with x = 0:12 the correlations along the c-axis were investigated. It was found......O4+y were performed, with a number of interesting results. There was evidence of a small gap below 0.5 meV, and the intensity of the uctuations above this energy was found to decrease with increasing applied magnetic eld, contrary to expectations. The most likely explanation is that the magnetic eld...

  9. Simultaneous EEG-fMRI at ultra-high field: artifact prevention and safety assessment.

    Science.gov (United States)

    Jorge, João; Grouiller, Frédéric; Ipek, Özlem; Stoermer, Robert; Michel, Christoph M; Figueiredo, Patrícia; van der Zwaag, Wietske; Gruetter, Rolf

    2015-01-15

    The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7 T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12 cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although

  10. Study of local correlations of magnetic and multiferroic compounds

    CERN Multimedia

    Alves, E J

    We propose to study magnetic and multiferroic strongly correlated electron materials using radioactive nuclear probe techniques, at ISOLDE . Following the strategy of a previous project, IS390, our aim is to provide local and element selective information on some of the mechanisms that rule structural, charge and orbital correlations, electronic and magnetic interactions and the coupling of the associated degrees of freedom. The main technique used is Perturbed Angular Correlations (PAC), which allows combined magnetic and electric hyperfine studies. This study is complemented by the use of conventional characterisation techniques, and the investigation of relevant macroscopic properties.

  11. Magnetic studies in evaporated Ni/Pd multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Chafai, K. [Laboratoire de Physique des Materiaux, Micro-electronique, Automatique et Thermique (LPMMAT), Faculte des Sciences Ain Chock, Universite Hassan II, B.P. 5366 Maarif, Casablanca (Morocco); Salhi, H. [Laboratoire de Physique des Materiaux, Micro-electronique, Automatique et Thermique (LPMMAT), Faculte des Sciences Ain Chock, Universite Hassan II, B.P. 5366 Maarif, Casablanca (Morocco); Laboratoire de Mecanique, Productique et Genie industriel (LMPG), Ecole superieure de technologie, Universite Hassan II, B.P. 5366 Maarif, Casablanca (Morocco); Lassri, H., E-mail: lassrih@hotmail.co [Laboratoire de Physique des Materiaux, Micro-electronique, Automatique et Thermique (LPMMAT), Faculte des Sciences Ain Chock, Universite Hassan II, B.P. 5366 Maarif, Casablanca (Morocco); Yamkane, Z.; Lassri, M. [Laboratoire de Physique des Materiaux, Micro-electronique, Automatique et Thermique (LPMMAT), Faculte des Sciences Ain Chock, Universite Hassan II, B.P. 5366 Maarif, Casablanca (Morocco); Abid, M. [Laboratoire de Physique Fondamentale et Appliquee (LPFA), Faculte des Sciences Ain Chock, Universite Hassan II, B.P. 5366 Maarif, Casablanca (Morocco); Hlil, E.K. [Institut Neel, CNRS-Universite J. Fourier, BP 166, 38042 Grenoble (France); Krishnan, R. [Laboratoire de Magnetisme et d' Optique, URA 1531, 45 Avenue des Etats Unis, 78035 Versailles Cedex (France)

    2011-03-15

    The magnetic properties of Ni/Pd multilayers, prepared by sequential evaporation in ultrahigh vacuum, have been studied. The Ni thickness dependence of the magnetization and magnetic anisotropy is discussed. The temperature dependence of the spontaneous magnetization is well described by a T{sup 3/2} law in all multilayers. A spin-wave theory has been used to explain the temperature dependence of the spontaneous magnetization, and the approximate values for the exchange interactions for various Ni layer thicknesses have been obtained. - Research highlights: The magnetic properties of Ni/Pd multilayers, prepared by sequential evaporation in ultrahigh vacuum, have been studied. The temperature dependence of the spontaneous magnetization is well described by a T{sup 3/2} law in Ni/Pd multilayers. The spin-wave constant B was observed to depend on t{sub Ni} nonmonotonically. A spin-wave theory has been used to explain the temperature dependence of the spontaneous magnetization. The approximate values for the exchange interactions for various Ni layer thicknesses have been obtained.

  12. Detector tests in a high magnetic field and muon spectrometer triggering studies on a small prototype for an LHC experiment

    CERN Document Server

    Ambrosi, G; Basile, M; Battiston, R; Bergsma, F; Castro, H; Cifarelli, Luisa; Cindolo, F; Contin, A; De Pasquale, S; Gálvez, J; Gentile, S; Giusti, P; Laurent, G; Levi, G; Lin, Q; Maccarrone, G D; Mattern, D; Nania, R; Rivera, F; Schioppa, M; Sharma, A; CERN. Geneva. Detector Research and Development Committee

    1990-01-01

    The "Large Area Devices" group of the LAA project is working on R&D for muon detection at a future super-collider. New detectors are under development and the design of a muon spectrometer for an LHC experiment is under study. Our present choice is for a compact, high field, air-core toroidal muon spectrometer. Good momentum resolution is achievable in this compact solution, with at least one plane of detection elements inside the high field region. A new detector, the Blade Chamber, making use of blades instead of wires, has been developed for the forward and backward regions of the spectrometer, where polar coordinate readings are desirable.The assembling of a CERN high energy beam line, equipped with high resolution drift chambers and a strong field magnet could give us the opportunity to test our chambers in a high magnetic field and to study the muon trigger capabilities of a spectrometer, like the one proposed, on a small prototype.

  13. Photoemission and core-level magnetic circular dichroism studies of diluted magnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Fujimori, A. [Department of Complexity Science and Engineering, Universtiy of Tokyo, 1-5-1 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan) and Synchrotron Radiation Research Center, Japan Atomic Energy Research Institute, SPring-8, Mikazuki, Hyogo 679-5148 (Japan)]. E-mail: fujimori@phys.s.u-tokyo.ac.jp; Okabayashi, J. [Department of Applied Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyou-ku, Tokyo 113-8656 (Japan); Takeda, Y. [Synchrotron Radiation Research Center, Japan Atomic Energy Research Institute, SPring-8, Mikazuki, Hyogo 679-5148 (Japan); Mizokawa, T. [Department of Complexity Science and Engineering, Universtiy of Tokyo, 1-5-1 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Okamoto, J. [Synchrotron Radiation Research Center, Japan Atomic Energy Research Institute, SPring-8, Mikazuki, Hyogo 679-5148 (Japan); Mamiya, K. [Photon Factory, IMSS, High Energy Accelerator Research Organization, Tsukuba, Ibaraki 305 (Japan); Saitoh, Y. [Synchrotron Radiation Research Center, Japan Atomic Energy Research Institute, SPring-8, Mikazuki, Hyogo 679-5148 (Japan); Muramatsu, Y. [Synchrotron Radiation Research Center, Japan Atomic Energy Research Institute, SPring-8, Mikazuki, Hyogo 679-5148 (Japan); Oshima, M. [Department of Applied Chemistry, University of Tokyo, 7-3-1 Hongo, Bunkyou-ku, Tokyo 113-8656 (Japan); Ohya, S. [Department of Electronic Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan); Tanaka, M. [Department of Electronic Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2005-06-15

    An overview is given on the photoemission studies of the electronic structure of diluted magnetic semiconductors (DMS's), in particular of the prototypical ferromagnetic DMS Ga{sub 1-x}Mn{sub x}As. Configuration-interaction cluster-model analyses of the photoemission data allow us to estimate the p-d exchange coupling constant and hence to predict how to increase the Curie temperature in new materials. Spectra near the Fermi level combined with the transport and optical properties suggest a highly incoherent metallic state for the ferromagnetic metallic phase. It is shown that new insight into the chemically and magnetically inhomogeneous states of DMS's can be gained by the temperature and magnetic field dependence of core-level magnetic circular dichroism signals.

  14. Detailed magnetic study on the formato-bridged MOFs with anion-tunable magnetic properties

    Institute of Scientific and Technical Information of China (English)

    WANG XinYi; WANG ZheMing; GAO Song

    2012-01-01

    Detailed studies of the structures,magnetic properties and photodimerization of a series of formato-bridged MOFs with the general formula M2(HCOO)3(4,4'-bpe)3(H20)3(X)(4,4'-bpe =4,4'-bipyridylethylene,M =Mn(l-X-),X- =CIO-4,NO-3,BF-4,I-,Br-; M =Co(2-X-),X- =CIO-4,NO-3; M =Zn(3-X-),X- =NO-3)were reported.Careful magnetic measurements on an oriented single crystal of 1-ClO-4 determined the spin-flop magnetic phase diagram and some intrinsic parameters,such as the intralayer coupling J,the anisotropy field HA and the exchange field HE.Different anions can remarkably tune the magnetic properties of l-X-,especially the critical fields of the spin-flop transition.Compound 2-ClO-4 remained paramagnetic down to 2 K.

  15. Resonance magnetic x-ray scattering study of erbium

    DEFF Research Database (Denmark)

    Sanyal, M.K.; Gibbs, D.; Bohr, J.

    1994-01-01

    The magnetic phases of erbium have been studied by resonance x-ray-scattering techniques. When the incident x-ray energy is tuned near the L(III) absorption edge, large resonant enhancements of the magnetic scattering are observed above 18 K. We have measured the energy and polarization dependence...... of this magnetic scattering and analyzed it using a simple model based on electric dipole and quadrupole transitions among atomic orbitals. The line shapes can be fitted to a magnetic structure combining both c-axis-modulated and basal-plane components. Below 18 K, we have observed unusual behavior of the magnetic...... scattering as a function of energy, whose origin is not understood....

  16. Structural and magnetic study of dysprosium substituted cobalt ferrite nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Hemaunt, E-mail: hvatsal@gmail.com [Department of Physics, Govind Ballabh Pant University of Agr. & Technology, Pantnagar, Uttarakhand 263145 (India); Srivastava, R.C. [Department of Physics, Govind Ballabh Pant University of Agr. & Technology, Pantnagar, Uttarakhand 263145 (India); Pal Singh, Jitendra [Advanced Analysis Centre, Korea Institute of Science and Technology, Seoul 02792 (Korea, Republic of); Negi, P. [Department of Physics, Govind Ballabh Pant University of Agr. & Technology, Pantnagar, Uttarakhand 263145 (India); Agrawal, H.M. [Advanced Analysis Centre, Korea Institute of Science and Technology, Seoul 02792 (Korea, Republic of); Das, D. [UGC-DAE CSR Kolkata Centre, Kolkata 700098 (India); Hwa Chae, Keun [Advanced Analysis Centre, Korea Institute of Science and Technology, Seoul 02792 (Korea, Republic of)

    2016-03-01

    The present work investigates the magnetic behavior of Dy{sup 3+} substituted cobalt ferrite nanoparticles. X-ray diffraction studies reveal presence of cubic spinel phases in these nanoparticles. Raman spectra of these nanoparticles show change in intensity of Raman bands, which reflects cation redistribution in cubic spinel lattice. Saturation magnetization and coercivity decrease with increase of Dy{sup 3+}concentration in these nanoparticles. Room temperature Mössbauer measurements show the cation redistribution in these nanoparticles and corroborates the results obtained from Raman Spectroscopic measurements. Decrease in magnetization of Dy{sup 3+} substituted cobalt ferrite is attributed to the reduction in the magnetic interaction and cation redistribution. - Highlights: • Slight decrease in crystallite size after Dy{sup 3+} doping. • Saturation magnetization and coercivity decrease after Dy{sup 3+} doping. • Mössbauer measurements show the cation redistribution in the samples.

  17. Ac magnetic susceptibility study of in vivo nanoparticle biodistribution

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, L; Veintemillas-Verdaguer, S; Serna, C J; Morales, M P [Instituto de Ciencia de Materiales de Madrid, ICMM-CSIC, Sor Juana Ines de la Cruz 3, Cantoblanco 28049, Madrid (Spain); MejIas, R; Barber, D F [Centro Nacional de BiotecnologIa, CNB-CSIC, Darwin 3, Cantoblanco 28049, Madrid (Spain); Lazaro, F J, E-mail: lucia@icmm.csic.es [Departamento de Ciencia y Tecnologia de Materiales y Fluidos, Universidad de Zaragoza, Maria de Luna 3, 50018, Zaragoza (Spain)

    2011-06-29

    We analysed magnetic nanoparticle biodistribution, before and after cytokine conjugation, in a mouse model by ac susceptibility measurements of the corresponding resected tissues. Mice received repeated intravenous injections of nanoparticle suspension for two weeks and they were euthanized 1 h after the last injection. In general, only 10% of the total injected nanoparticles after multiple exposures were found in tissues. The rest of the particles may probably be metabolized or excreted by the organism. Our findings indicate that the adsorption of interferon to DMSA-coated magnetic nanoparticles changes their biodistribution, reducing the presence of nanoparticles in lungs and therefore their possible toxicity. The specific targeting of the particles to tumour tissues by the use of an external magnetic field has also been studied. Magnetic nanoparticles were observed by transmission electron microscopy in the targeted tissue and quantified by ac magnetic susceptibility.

  18. New concepts in the design of high field systems

    Energy Technology Data Exchange (ETDEWEB)

    Schneider-Muntau, H.J. (Hochfeld-Magnetlabor Grenoble, 38 - Grenoble (France))

    1984-01-01

    A polyhelix magnet with a Bitter coil (duplex magnet) or with a superconducting coil (hybrid magnet) for the background field generation, is known to produce the highest magnetic fields. Numerical calculations involving system parameters established in the course of 1000 hours of operation of the Grenoble duplex magnet are used for designing the 30 T hybrid magnet. It is demonstrated that with a power of 10 MW continuous magnetic fields of 30 T with a duplex magnet and 40 T with a hybrid magnet are feasible.

  19. Magnetic field effects on humans: epidemiological study design

    Energy Technology Data Exchange (ETDEWEB)

    Budinger, T.F.; Wong, P.; Yen, C.K.

    1978-10-01

    This report presents details of the study design and methods for a retrospective epidemiological study on the health effects, if any, of stationary and alternating magnetic fields produced by man-made devices such as cyclotrons, controlled thermonuclear reactors (CTR), high voltage-high current transmission lines, magnetohydrodynamic devices (MHD), energy storage systems, and isotope separation facilities. The magnetic fields to which the workers can be exposed are as high as 10,000 gauss and the anticipated increase in magnetic fields associated with the environment and transmission lines near these devices is a few times the natural earth magnetic field. Thus the objectives include acquisition of low exposure data which can be used to evaluate any risks to the population incidentally exposed to environmental increases in magnetic fields, as well as an acquisition of high exposure data to be used in determining allowable exposure standards for the technical personnel working at CTR and MHD facilities. From the present status of knowledge on biological effects of magnetic fields, it is not possible to extrapolate or rationally conclude maximum permissible exposure levels for magnetic device workers and the population at large. There are no known previous studies of the effects of long-term exposure to magnetic fields involving large samples and matched controls. Thus this human epidemiological study was commenced in 1977 in parallel with experimental studies on biological and medical effects of magnetic fields being conducted by Dr. T. Tenforde and co-workers at LBL, by investigators at Battelle Northwest, and smaller projects at a number of laboratories around the world. The data base for the exposed population is comprised of approximately 1,000 cyclotron and bubble chamber workers.

  20. Soft X-ray techniques to study mesoscale magnetism

    Energy Technology Data Exchange (ETDEWEB)

    Kortright, Jeffrey B.

    2003-06-26

    Heterogeneity in magnetization (M) is ubiquitous in modern systems. Even in nominally homogeneous materials, domains or pinning centers typically mediate magnetization reversal. Fundamental lengths determining M structure include the domain wall width and the exchange stiffness length, typically in the 4-400 nm range. Chemical heterogeneity (phase separation, polycrystalline microstructure, lithographic or other patterning, etc.) with length scales from nanometers to microns is often introduced to influence magnetic properties. With 1-2 nm wavelengths {lambda}, soft x-rays in principle can resolve structure down to {lambda}/2, and are well suited to study these mesoscopic length scales [1, 2]. This article highlights recent advances in resonant soft x-ray methods to resolve lateral magnetic structure [3], and discusses some of their relative merits and limitations. Only techniques detecting x-ray photons (rather than photo-electrons) are considered [4], since they are compatible with strong applied fields to probe relatively deeply into samples. The magneto-optical (MO) effects discovered by Faraday and Kerr were observed in the x-ray range over a century later, first at ''hard'' wavelengths in diffraction experiments probing interatomic magnetic structure [5]. In the soft x-ray range, magnetic linear [6] and circular [7] dichroism spectroscopies first developed that average over lateral magnetic structure. These large resonant MO effects enable different approaches to study magnetic structure or heterogeneity that can be categorized as microscopy or scattering [1]. Direct images of magnetic structure result from photo-emission electron microscopes [4, 8] and zone-plate microscopes [9, 10]. Scattering techniques extended into the soft x-ray include familiar specular reflection that laterally averages over structure but can provide depth-resolved information, and diffuse scattering and diffraction that provide direct information about lateral

  1. Tunnel-diode resonator and nuclear magnetic resonance studies of low-dimensional magnetic and superconducting systems

    Science.gov (United States)

    Yeninas, Steven Lee

    This thesis emphasizes two frequency-domain techniques which uniquely employ radio frequency (RF) excitations to investigate the static and dynamic properties of novel magnetic and superconducting materials. The first technique is a tunnel-diode resonator (TDR) which detects bulk changes in the dynamic susceptibility, chi = dM/dH. The capability of TDR to operate at low temperatures (less than 100 mK) and high fields (up to 65 T in pulsed fields) was critical for investigations of the antiferromagnetically correlated magnetic molecules Cr12Cu2 and Cr12 Ln4 (Ln = Y, Eu, Gd, Tb, Dy, Ho, Er, Yb), and the superconductor SrFe2(As1--xPx) 2 (x = 0.35). Investigations of Cr12Cu 2 and Cr12Ln4 demonstrates the first implementation of TDR to experimentally investigate the lowlying energy spectra of magnetic molecules in pulsed magnetic fields. Zeeman splitting of the quantum spin states results in transitions between field-dependent ground state energy levels observed as peaks in dM/dH at 600 mK, and demonstrate good agreement with theoretical calculations using a isotropic Heisenberg spin Hamiltonian. Increasing temperature to 2.5 K, TDR reveals a rich spectrum of frequency-dependent level crossings from thermally populated excited states which cannot be observed by conventional static magnetometry techniques. The last study presented uses TDR in pulsed fields to determine the temperature-dependent upper-critical field Hc2 to investigate the effects of columnar defects arising from heavy ion irradiation of SrFe2(As 1--xPx)2. Results suggest irradiation uniformly suppresses Tc and Hc2, and does not introduce additional features on H c2(T) and the shapes of the anisotropic Hc2 curves indicates a nodal superconducting gap. The second technique is nuclear magnetic resonance (NMR) which yields site specific magnetic and electronic information arising from hyperfine interactions for select magnetic nuclei. NMR spectra and nuclear spin-lattice relaxation measurements are reported

  2. Optical Signatures from Magnetic 2-D Electron Gases in High Magnetic Fields to 60 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Crooker, S.A.; Kikkawa, J.M.; Awschalom, D.D.; Smorchikova, I.P.; Samarth, N.

    1998-11-08

    We present experiments in the 60 Tesla Long-Pulse magnet at the Los Alamos National High Magnetic Field Lab (NHMFL) focusing on the high-field, low temperature photoluminescence (PL) from modulation-doped ZnSe/Zn(Cd,Mn)Se single quantum wells. High-speed charge-coupled array detectors and the long (2 second) duration of the magnet pulse permit continuous acquisition of optical spectra throughout a single magnet shot. High-field PL studies of the magnetic 2D electron gases at temperatures down to 350mK reveal clear intensity oscillations corresponding to integer quantum Hall filling factors, from which we determine the density of the electron gas. At very high magnetic fields, steps in the PL energy are observed which correspond to the partial unlocking of antiferromagnetically bound pairs of Mn2+ spins.

  3. Study of a Floated Pendulum Accelerometer with Passive Magnetic Suspension

    OpenAIRE

    TAKIZAWA, Minoru; OOTSUKI, Masao; Suzuki, Takao; 滝沢, 実; 大月, 正男; 鈴木,孝雄

    1980-01-01

    In the last few years, in order to develop more precise inertial sensors, such as floated gyros and floated accelerometers used in the inertial navigation system, a passive magnetic suspension with an eight-pole stator, that can be applied to support the output axes of the sensors, has been theoretically and experimentally studied at NAL (National Aerospace Laboratory). In our previous reports, 7)~10)29) a theoretical analysis and an experimental study of the magnetic suspension were describe...

  4. A Study on Magnetic Decoupling of Compound-Structure Permanent-Magnet Motor for HEVs Application

    Directory of Open Access Journals (Sweden)

    Qiwei Xu

    2016-10-01

    Full Text Available The compound-structure permanent-magnet (CSPM motor is used for an electrical continuously-variable transmission (E-CVT in a hybrid electric vehicle (HEV. It can make the internal combustion engine (ICE independent of the road loads and run in the high efficiency area to improve the fuel economy and reduce the emissions. This paper studies the magnetic coupling of a new type of CSPM motor used in HEVs. Firstly, through the analysis of the parameter matching with CSPM in the HEV, we receive the same dynamic properties’ design parameters between the CSPM motor and the THS (Toyota Hybrid System of the Toyota Prius. Next, we establish the equivalent magnetic circuit model of the overall and the secondary model considering the tangential and radial flux distribution in the outer rotor of the CSPM motor. Based on these two models, we explore the internal magnetic coupling rule of the CSPM motor. Finally, finite element method analysis in 2D-ansoft is used to analyze the magnetic field distribution of the CSPM motor in different operation modes. By the result of the finite element method analysis, the internal magnetic decoupling scheme is put forward, laying the theoretical foundation for the further application of the CSPM motor in HEVs.

  5. Local Magnetic Fields in Ferromagnetics Studied by Positive Muon Precession

    CERN Multimedia

    2002-01-01

    Positive muons are used to study local magnetic fields in different materials. A polarized muon beam is employed with energies of 30-50 MeV, and the muons are stopped in the target being studied. During its lifetime the muon will precess in the magnetic fields present, and after the decay of the muon the emitted positron is detected in plastic scintillators. The time and angle of the detected positron is used to calculate the magnetic field at the position of the muon in the sample. \\\\ \\\\ The detector system consists of plastic scintillators. Most of the measurements are made in an applied magnetic field. A dilution cryostat is used to produce temperatures down to well below $ 1 ^0 $ K. \\\\ \\\\ The present line of experiments concern mainly: \\item a)~~~~Local magnetism in the paramagnetic state of the Lave's phase type REAl$_{2} $ and RENi$_{2} $ systems ~~~where RE is a rare-earth ion. \\item b)~~~~Local magnetic fields and critical behaviour of the magnetism in Gd metal. \\item c)~~~~Investigation of flux exclu...

  6. High-Gain High-Field Fusion Plasma

    Science.gov (United States)

    Li, Ge

    2015-01-01

    A Faraday wheel (FW)—an electric generator of constant electrical polarity that produces huge currents—could be implemented in an existing tokamak to study high-gain high-field (HGHF) fusion plasma, such as the Experimental Advanced Superconducting Tokamak (EAST). HGHF plasma can be realized in EAST by updating its pulsed-power system to compress plasma in two steps by induction fields; high gains of the Lawson trinity parameter and fusion power are both predicted by formulating the HGHF plasma. Both gain rates are faster than the decrease rate of the plasma volume. The formulation is checked by earlier ATC tests. Good agreement between theory and tests indicates that scaling to over 10 T at EAST may be possible by two-step compressions with a compression ratio of the minor radius of up to 3. These results point to a quick new path of fusion plasma study, i.e., simulating the Sun by EAST. PMID:26507314

  7. Neutron Diffraction Studies of Nuclear Magnetic Ordering in Copper

    DEFF Research Database (Denmark)

    Jyrkkiö, T.A.; Huiku, M.T.; Siemensmeyer, K.;

    1989-01-01

    to depend strongly on the external magnetic field between zero and the critical fieldB c=0.25 mT, indicating the existence of at least two antiferromagnetic phases. The results are compared to previous measurements of the magnetic susceptibility. Theoretical calculations do not provide a full explanation......We have constructed a two-stage nuclear demagnetization cryostat for neutron diffraction studies of nuclear magnetism in copper. The cryostat is combined with a two-axis neutron spectrometer which can use both polarized and unpolarized neutrons. By demagnetizing highly polarized copper nuclear...

  8. Theoretical study of in-plane response of magnetic field sensor to magnetic beads magnetized by the sensor self-field

    DEFF Research Database (Denmark)

    Hansen, Troels Borum Grave; Damsgaard, Christian Danvad; Dalslet, Bjarke Thomas

    2010-01-01

    We present a theoretical study of the spatially averaged in-plane magnetic field on square and rectangular magnetic field sensors from a single magnetic bead, a monolayer of magnetic beads, and a half-space filled with magnetic beads being magnetized by the magnetic self-field due to the applied...... bias current through the sensor. The analysis of the single bead response shows that beads always contribute positively to the average magnetic field as opposed to the case for an applied homogeneous magnetic field where the sign of the signal depends on the bead position. General expressions...... and analytical approximations are derived for the sensor response to beads as function of the bead distribution, the bias current, the geometry and size of the sensor, and the bead characteristics. Consequences for the sensor design are exemplified and it is described how the contribution from the self...

  9. Rotatable Small Permanent Magnet Array for Ultra-Low Field Nuclear Magnetic Resonance Instrumentation: A Concept Study.

    Directory of Open Access Journals (Sweden)

    Michael W Vogel

    Full Text Available We studied the feasibility of generating the variable magnetic fields required for ultra-low field nuclear magnetic resonance relaxometry with dynamically adjustable permanent magnets. Our motivation was to substitute traditional electromagnets by distributed permanent magnets, increasing system portability.The finite element method (COMSOL® was employed for the numerical study of a small permanent magnet array to calculate achievable magnetic field strength, homogeneity, switching time and magnetic forces. A manually operated prototype was simulated and constructed to validate the numerical approach and to verify the generated magnetic field.A concentric small permanent magnet array can be used to generate strong sample pre-polarisation and variable measurement fields for ultra-low field relaxometry via simple prescribed magnet rotations. Using the array, it is possible to achieve a pre-polarisation field strength above 100 mT and variable measurement fields ranging from 20-50 μT with 200 ppm absolute field homogeneity within a field-of-view of 5 x 5 x 5 cubic centimetres.A dynamic small permanent magnet array can generate multiple highly homogeneous magnetic fields required in ultra-low field nuclear magnetic resonance (NMR and magnetic resonance imaging (MRI instruments. This design can significantly reduce the volume and energy requirements of traditional systems based on electromagnets, improving portability considerably.

  10. Open Science CBS Neuroimaging Repository: Sharing ultra-high-field MR images of the brain.

    Science.gov (United States)

    Tardif, Christine Lucas; Schäfer, Andreas; Trampel, Robert; Villringer, Arno; Turner, Robert; Bazin, Pierre-Louis

    2016-01-01

    Magnetic resonance imaging at ultra high field opens the door to quantitative brain imaging at sub-millimeter isotropic resolutions. However, novel image processing tools to analyze these new rich datasets are lacking. In this article, we introduce the Open Science CBS Neuroimaging Repository: a unique repository of high-resolution and quantitative images acquired at 7 T. The motivation for this project is to increase interest for high-resolution and quantitative imaging and stimulate the development of image processing tools developed specifically for high-field data. Our growing repository currently includes datasets from MP2RAGE and multi-echo FLASH sequences from 28 and 20 healthy subjects respectively. These datasets represent the current state-of-the-art in in-vivo relaxometry at 7 T, and are now fully available to the entire neuroimaging community. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. 高场强术中磁共振成像及神经导航在累及视放射的颞叶胶质瘤手术中的应用%Intraoperative high-field magnetic resonance imaging combined with functional neuronavigation in resection of low-grade temporal lobe tumors involving optic radiation

    Institute of Scientific and Technical Information of China (English)

    白少聪; 陈晓雷; 耿杰峰; 吴东东; 余新光; 许百男

    2015-01-01

    Objective To investigate the clinical value of high-field-strength intraoperative magnetic resonance imaging (iMRI) combined with optic radiation neuro-navigation for the resection of temporal lobe low-grade gliomas.Methods From April 2009 to September 2013,65 patients with temporal lobe lowgrade gliomas (WHO grade Ⅱ) involving optic radiation were operated with iMRI and functional neuronavigation.Diffusion tensor imaging (DTI) based fiber tracking was used to delineate optic radiation.The reconstructed optic radiations were integrated into a navigation system,in order to achieve intraoperative microscopic-based functional neuro-navigation,iMRI was used to update the images for both optic radiations and residual tumors.Volumetric analyses were performed using 3D Slicer for pre-and intra-operative tumor volumes in all cases.All patients were evaluated for visual field deficits preoperatively and postoperatively.The Student t test was used to evaluate the average rate of extent of resection between groups.Spearman rank correlation analysis was used to assess correlations between predictors and epilepsy prognosis.Results Preoperative tumor volumes were (78 ±40) cm3.In 29 cases,iMRI scan detected residual tumor that could be further resected,and extent of resection were increased from 76.2% to 92.7% (t =7.314,P <0.01).In 19 cases (29.2%),gross total resection was accomplished,and iMRI contributed directly to 8 of these cases.Postsurgical follow-up period varied from 13 months to 59 months,mean (33 ± 13) months.Tumor progression were observed in 3 patients,newly developed or deteriorated visual field defects occurred in 4 patients (6.2%).For patients with pre-operative seizures,Engel Class Ⅰ were achieved for 89.7% of them.Spearman rank correlation analysis revealed that seizure outcome (Engel Class) was related to increased excision of ratio (r =-0.452,P =0.004,95% CI:-0.636--0.261) and larger tumors (r =0.391,P =0.014,95% CI:0

  12. Multifunctional magnetic rotator for micro and nanorheological studies

    Science.gov (United States)

    Tokarev, Alexander; Aprelev, Alexey; Zakharov, Mikhail N.; Korneva, Guzeliya; Gogotsi, Yury; Kornev, Konstantin G.

    2012-06-01

    We report on the development of a multifunctional magnetic rotator that has been built and used during the last five years by two groups from Clemson and Drexel Universities studying the rheological properties of microdroplets. This magnetic rotator allows one to generate rotating magnetic fields in a broad frequency band, from hertz to tens kilohertz. We illustrate its flexibility and robustness by conducting the rheological studies of simple and polymeric fluids at the nano and microscale. First we reproduce a temperature-dependent viscosity of a synthetic oil used as a viscosity standard. Magnetic rotational spectroscopy with suspended nickel nanorods was used in these studies. As a second example, we converted the magnetic rotator into a pump with precise controlled flow modulation. Using multiwalled carbon nanotubes, we were able to estimate the shear modulus of sickle hemoglobin polymer. We believe that this multifunctional magnetic system will be useful not only for micro and nanorheological studies, but it will find much broader applications requiring remote controlled manipulation of micro and nanoobjects.

  13. An MFM Study of Magnetic Domains in Magnetoelastic Torque Sensors

    Science.gov (United States)

    Wilson, Jason; Boley, Mark S.

    2003-03-01

    We have determined that a ferromagnetic high-speed maraging steel alloy of 18the best materials for use in the construction of a "ring type" torque sensor on a non-ferromagnetic shaft used for power transmission applications. We created two distinct portions of the ring in which a high degree of oppositely polarized circumferential magnetization was maintained with a saturated alignment of the magnetic domains due to the high circumferential coercive force. The same type of magnetic arrangement can be produced in a hollow ferromagnetic "shaft type" torque sensor. The two shafts used were steel alloys, of 0.5and of 12respectively). Previously unknown has been the exact nature of the interface between the regions of opposing circumferential magnetization. In this study, we have used the magnetic force probe of our AFM, in an imaging technique known as MFM, to determine the width and sharpness of the domain wall transition region between the two oppositely polarized regions of both types of sensors and their relative depth of magnetic alignment. We found the domain wall transition region to be much wider and to change in a more gradual manner in the shaft sensors. We also found the D-2 shaft sensor to have a depth of magnetic alignment on the order of that of the ring sensor, with the O-1 sensor showing a severely reduced alignment.

  14. STUDYING THE INTERSTELLAR MAGNETIC FIELD FROM ANISOTROPIES IN VELOCITY CHANNELS

    Energy Technology Data Exchange (ETDEWEB)

    Esquivel, A. [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Apartado Postal 70-543, 04510 México D.F., México (Mexico); Lazarian, A. [Astronomy Department, University of Wisconsin–Madison, 475 N. Charter Street, Madison, WI (United States); Pogosyan, D., E-mail: esquivel@nucleares.unam.mx, E-mail: lazarian@astro.wisc.edu, E-mail: pogosyan@ualberta.ca [Physics Department, University of Alberta, Edmonton, AB (Canada)

    2015-11-20

    Turbulence in the interstellar medium is anisotropic due to the ubiquitous magnetic fields. This anisotropy depends on the strength of the magnetic field and leaves an imprint on observations of spectral line maps. We use a grid of ideal magnetohydrodynamic simulations of driven turbulence and produce synthetic position–position–velocity maps to study the turbulence anisotropy in velocity channels of various resolutions. We found that the average structure function of velocity channels is aligned with the projection of the magnetic field on the plane of the sky. We also found that the degree of such anisotropy increases with the magnitude of the magnetic field. For thick velocity channels (low velocity resolution), the anisotropy is dominated by density, and the degree of anisotropy in these maps allows one to distinguish sub-Alfvénic and super-Alfvénic turbulence regimes, but it also depends strongly on the sonic Mach number. For thin channels (high velocity resolution), we find that the anisotropy depends less on the sonic Mach number. An important limitation of this technique is that it only gives a lower limit on the magnetic field strength because the anisotropy is related only to the magnetic field component on the plane of the sky. It can, and should, be used in combination with other techniques to estimate the magnetic field, such as the Fermi-Chandrasekhar method, anisotropies in centroids, Faraday rotation measurements, or direct line-of-sight determinations of the field from Zeeman effect observations.

  15. Feasibility study of fast neutron energy spectrometer using magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Yamagishi, Hideshi; Ara, Katsuyuki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-09-01

    A feasibility study of a fast neutron energy spectrometer (NES) using magnetic field was performed for development of a spectrometer having a measuring range of 3 decades and a covered energy range of 8 decades. The NES that is a kind of proton recoil spectrometer consists of a proton radiator, a magnet and a screen to detect protons. The pass of each charge particle flying into the magnetic field is deflected with a certain angle depending on the velocity of the particle, and it reaches the screen of charged particle detection after passing through the magnetic field. The energy of the particle is measured from the position on the screen at which the particle collide with. In this paper, optimization of the magnet geometry and the magnetic field intensity of the NES are discussed. The NES that is designed with the optimized geometry provides the measuring range of 3 decades with an energy measuring error of less than {+-}9%. A neutron energy range of 9 decades from 0.1 (eV) to 100 (MeV) is covered by adjusting the magnetic flux density. (author)

  16. Magnetic studies on Shergotty and other SNC meteorites

    Science.gov (United States)

    Cisowski, S. M.

    1986-01-01

    The results of a study of basic magnetic properties of meteorites within the SNC group, including the four known shergottites and two nakhlites, are presented. An estimate is made of the strength of the magnetic field which produced the remanent magnetization of the Shergotty meteorite, for the purpose of constraining the choices for the parent body of these SNC meteorites. Remanence measurements in several subsamples of Shergotty and Zagami meteorites reveal a large variation in intensity that does not seem to be related to the abundance of remanence carriers. The other meteorites carry only weak remanence, suggesting weak magnetizing fields as the source of their magnetic signal. A paleointensity experiment on a weakly magnetized subsample of Shergotty revealed a low temperature component of magnetization acquired in a field of 2000 gammas, and a high temperature component reflecting a paleofield strength of between 250 and 1000 gammas. The weak field environment that these meteorites seem to reflect is consistent with either a Martian or asteroidal origin, but inconsistent with a terrestrial origin.

  17. High field transport properties of MBE processed Fe-based superconducting thin films

    Energy Technology Data Exchange (ETDEWEB)

    Iida, Kazumasa [Nagoya University (Japan); IFW Dresden (Germany)

    2015-07-01

    It has been reported that Fe-based superconductors show high upper critical fields with low anisotropies at low temperatures. Hence these materials may offer a unique possibility for high field magnet applications. However, only a few reports on high-field transport properties of Co-doped Ba-122 and Fe(Se,Te) have been published and the only one for SmFeAs(O,F) thin films to date. In order to use this material class for applications, the knowledge of in-field and its orientation dependence of transport properties in a wide range of external fields need to be clarified. In this talk, I will report on high-field (up to dc 45 T) transport properties of P-doped Ba-122, SmFeAs(O,F) and NdFeAs(O,F) thin films prepared by MBE. Although P-doped Ba-122 has the lowest T{sub c}, self-field J{sub c} of over 6 MA/cm{sup 2} at 4.2 K is recorded, which is the highest value ever reported in Fe-based superconductors. Additionally, in-field performance of P-doped Ba-122 shows comparable to those of NdFeAs(O,F) and SmFeAs(O,F) for Hc. On the other hand, both NdFeAs(O,F) and SmFeAs(O,F) exhibited higher J{sub c} for H parallel ab due to the intrinsic pinning. These results indicate that P-doped Ba-122 is the most promising candidates for high-field magnet applications.

  18. Study of a Mini-Actuator with Permanent Magnets

    Directory of Open Access Journals (Sweden)

    PETRESCU, C.

    2009-10-01

    Full Text Available The paper presents an analytical method for the determination of the magnetic force produced by a mini - actuator with permanent magnets. The results are compared with those obtained by performing a numerical field analysis with COMSOL Multiphysics, showing a very good agreement. The study reveals that the actuator has two equilibrium points, one of which is stable and the other one unstable.

  19. Optical and magnetization studies on europium based iron pnictides

    Energy Technology Data Exchange (ETDEWEB)

    Zapf, Sina Maria Ute

    2015-07-01

    The investigations carried out in the framework of this thesis mainly concentrate on europium based iron pnictides. These are a peculiar member of the 122 family as they develop at low temperatures (∝20K) an additional magnetic order of the local rare earth moments. Therefore, europium based iron pnictides provide a unique platform to study the interplay of structural, magnetic and electronic effects in high-temperature superconductors. For this challenging purpose, we have employed SQUID magnetometry and Fourier-transform infrared spectroscopy on EuFe{sub 2}(As{sub 1-x}P{sub x}){sub 2} single crystals. By systematic studies of the in- and out-of-plane magnetic properties of a series of single crystals, we derived the complex magnetic phase diagram of europium based iron pnictides, which contains an A-type antiferromagnetic and a re-entrant spin glass phase. Furthermore, we have investigated the magneto-optical properties of EuFe{sub 2}As{sub 2}, revealing a much more complex magnetic detwinning process than expected. These studies demonstrate a remarkable interdependence between magnetic, electronic and structural effects that might be very important to understand the unconventional superconductivity in these fascinating materials.

  20. Change of easy magnetization direction in TmMn{sub 6}Sn{sub 6-x}Ga {sub x} (0.00 < x < 1.22) studied in high magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Sawai, Y. [Kyokugen, Osaka University, Toyonaka, Osaka 560-8531 (Japan)]. E-mail: sawai@mag.rcem.osaka-u.ac.jp; Kindo, K. [Kyokugen, Osaka University, Toyonaka, Osaka 560-8531 (Japan); Zhang, L. [Van der Waals-Zeeman Instituut, Universiteit van Amsterdam, 1018 XE Amsterdam (Netherlands); Klaasse, J.C.P. [Van der Waals-Zeeman Instituut, Universiteit van Amsterdam, 1018 XE Amsterdam (Netherlands); Brueck, E. [Van der Waals-Zeeman Instituut, Universiteit van Amsterdam, 1018 XE Amsterdam (Netherlands); Buschow, K.H.J. [Van der Waals-Zeeman Instituut, Universiteit van Amsterdam, 1018 XE Amsterdam (Netherlands); Boer, F.R. de [Kyokugen, Osaka University, Toyonaka, Osaka 560-8531 (Japan); Van der Waals-Zeeman Instituut, Universiteit van Amsterdam, 1018 XE Amsterdam (Netherlands); Lefevre, C. [Lab. Chim. Sol. Mineral, Universite Henri Poincare-Nancy 1, 54506 Vandoeuvre les Nancy Cedex (France); Venturini, G. [Lab. Chim. Sol. Mineral, Universite Henri Poincare-Nancy 1, 54506 Vandoeuvre les Nancy Cedex (France)

    2006-02-09

    Single crystals of TmMn{sub 6}Sn{sub 6-x}Ga {sub x} compounds (0 {<=} x {<=} 1.22) obtained in a tin flux have been studied by thermomagnetic and high-field magnetization measurements. A collinear-antiferro to heli-magnetic transition at 324 K has been observed in TmMn{sub 6}Sn{sub 6}. Spin-reorientation transitions at low temperature are found in the compounds with x = 0.66 and 1.22. The magnetization curves in high fields at 4.2 K are interpreted to result from the competition between the Tm-Mn exchange interaction and the magnetocrystalline anisotropy of the Tm and Mn sublattices. A strong easy-plane anisotropy is favored for the Ga-poor compounds and a strong easy-axis anisotropy for the Ga-rich compounds while the compounds of intermediate Ga content (0.51 {<=} x {<=} 0.66) display rather weak magnetocrystalline anisotropy.

  1. Basic study of magnetic microwires for sensor applications: Variety of magnetic structures

    Science.gov (United States)

    Chizhik, Alexander; Zhukov, Arcady; Gonzalez, Julian; Stupakiewicz, Andrzej

    2017-01-01

    We examine magnetic glass-coated microwires used for magnetic sensors. Images of domain structures and magnetization reversal were obtained with magneto-optical Kerr microscopy. Of particular importance were temperature-induced transformations of surface magnetic structures. Different surface magnetic domains coexist, characterized by various domain periods, magnetization directions, and nobilities of domain walls.

  2. Parametric scaling study of a magnetically insulated thermionic vacuum switch

    Energy Technology Data Exchange (ETDEWEB)

    Vanderberg, B.H.; Eninger, J.E. [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Industrial Electrotechnology

    1996-02-01

    A parametric scaling study is performed on MINOS (Magnetically INsulated Opening Switch), a novel fast ({approximately}100 ns) high-power opening switch concept based on a magnetically insulated thermionic vacuum diode. Principal scaling parameters are the switch dimensions, voltage, current, applied magnetic field, and switching time. The scaling range of interest covers voltages up to 100 kV and currents of several kA. Fundamental scaling properties are derived from models of space-charge flow and magnetic cutoff. The scaling is completed with empirical results from the experimental MX-1 switch operated in an inductive storage pulsed power generator. Results are presented in diagrams showing voltage, current, power, and efficiency relationships and their limitations. The scaling is illustrated by the design of a megawatt average power opening switch for pulsed power applications. Trade-offs in the engineering of this type of switch are discussed.

  3. Structural and magnetic study of Mo-doped FINEMET

    Energy Technology Data Exchange (ETDEWEB)

    Silveyra, J.M., E-mail: jsilveyra@fi.uba.a [Laboratorio de Solidos Amorfos, INTECIN, Facultad de Ingenieria, Universidad de Buenos Aires-CONICET, Paseo Colon 850, (C1063ACV) Buenos Aires (Argentina); Cremaschi, V.J. [Laboratorio de Solidos Amorfos, INTECIN, Facultad de Ingenieria, Universidad de Buenos Aires-CONICET, Paseo Colon 850, (C1063ACV) Buenos Aires (Argentina); Miembro de la Carrera del Investigador del CONICET (Argentina); Janickovic, D.; Svec, P. [Institute of Physics, Slovak Academy of Sciences, Dubravska cesta 9, 845 11 Bratislava (Slovakia); Arcondo, B. [Laboratorio de Solidos Amorfos, INTECIN, Facultad de Ingenieria, Universidad de Buenos Aires-CONICET, Paseo Colon 850, (C1063ACV) Buenos Aires (Argentina)

    2011-02-15

    In this paper, a study of the structural and the magnetic correlation of the crystalline and amorphous phases in the nanocrystalline system Fe{sub 73.5}Si{sub 13.5}B{sub 9}Nb{sub 3-x}Mo{sub x}Cu{sub 1} (x=0, 1.5, 2, 3) was made. By means of Moessbauer spectroscopy, simple mass balance considerations and density measurements, both phases fractions and chemical compositions were calculated (in at%, wt% and vol%). Then, quasistatic magnetic measurements and ab initio calculations were used in a magnetic balance model in order to estimate the magnetic contribution of the remaining amorphous phase, which was compared to that of as-quenched amorphous samples of the same composition. The difference in both magnitudes showed the influence of penetrating fields and that these became more important for higher crystalline fractions.

  4. Co magnetic instability study in $RCo_{3}$ by XMCD

    CERN Document Server

    García, F; Takeuchi, A Y; Tolentino, H C N

    2001-01-01

    We have performed a temperature-dependent study of the Er L/sub 3/ and Co K edge X-ray magnetic circular dichroism (XMCD) in a (Er, Y)Co /sub 3/ system. The Co K XMCD signal shows a clear change at 35 K, which has been associated to a Co metamagnetic transition, previously reported. However, around the compensation temperature T/sub com/, no discontinuity is observed, as should be expected if the magnetic moments were just reversed. The observed smooth passage through T/sub com/ is interpreted as a transition from a collinear to a non- collinear Co ordering, where Co moments assume intermediate orientations. The analysis of the E2/E1 ratio has allowed us to gain some insight into the magnetic properties of the 5d band. Finally, from our XMCD measurements, it is possible to complete the magnetic phase diagram of (Er, Y)Co/sub 3/, previously proposed. (17 refs).

  5. Magnetic properties of checkerboard lattice: a Monte Carlo study

    Science.gov (United States)

    Jabar, A.; Masrour, R.; Hamedoun, M.; Benyoussef, A.

    2017-06-01

    The magnetic properties of ferrimagnetic mixed-spin Ising model in the checkerboard lattice are studied using Monte Carlo simulations. The variation of total magnetization and magnetic susceptibility with the crystal field has been established. We have obtained a transition from an order to a disordered phase in some critical value of the physical variables. The reduced transition temperature is obtained for different exchange interactions. The magnetic hysteresis cycles have been established. The multiples hysteresis cycle in checkerboard lattice are obtained. The multiples hysteresis cycle have been established. The ferrimagnetic mixed-spin Ising model in checkerboard lattice is very interesting from the experimental point of view. The mixed spins system have many technological applications such as in domain opto-electronics, memory, nanomedicine and nano-biological systems. The obtained results show that that crystal field induce long-range spin-spin correlations even bellow the reduced transition temperature.

  6. The value of conventional high-field MRI in MS in the light of the McDonald criteria: a literature review

    DEFF Research Database (Denmark)

    Larsen, Line Sofie Lunde; Larsson, H B W; Frederiksen, Jette Lautrup Battistini

    2010-01-01

    of lesions to be better at high field. Of the seven studies, six found more and bigger lesions at high-field MRI. In the present paper, the relevant MRI sequences are evaluated in detail. The detection of more lesions at high-field strength did not seem to lead to earlier diagnosis of clinically definite...

  7. Surface studies of magnetic thin films

    CERN Document Server

    Zeybek, O

    2000-01-01

    Despite the resonances of the various multiplet components the dichroism signal retains a uniform spectral shape. The well-resolved multiplet structures have been obtained in 5p photoemission of Tb using circularly polarised light. This multiplet structure is caused by the interaction between the core level photohole and those partially filled subshell, i.e. as result of the unpaired 4f and 5p electrons. In 4f levels of Tb(0001) films, the well-resolved surface component of the Tb sup 8 S sub 7 sub / sub 2 has been observed a separation of magnetic circular dichroism in the angular dependence effect for the surface layer and for the bulk. Depending on the preparation procedure, new iron superstructures on W(110) substrate have been observed. The photographs of the LEED images provide information about the ordered arrangement of atoms on the surface and the distances between the spots. These LEED patterns are also an evidence of crystal structure of iron films. The sharpness of the spots gives insight on how w...

  8. Structures and magnetic properties of Co-Zr-B magnets studied by first-principles calculations

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xin; Ke, Liqin; Nguyen, Manh Cuong; Wang, Cai-Zhuang, E-mail: wangcz@ameslab.gov; Ho, Kai-Ming, E-mail: kmh@ameslab.gov [Ames Laboratory, U.S. DOE and Department of Physics and Astronomy, Iowa State University, Ames, Iowa 50011 (United States)

    2015-06-28

    The structures and magnetic properties of Co-Zr-B alloys near the composition of Co{sub 5}Zr with B at. % ≤6% were studied using adaptive genetic algorithm and first-principles calculations. The energy and magnetic moment contour maps as a function of chemical composition were constructed for the Co-Zr-B magnet alloys through extensive structure searches and calculations. We found that Co-Zr-B system exhibits the same structure motif as the “Co{sub 11}Zr{sub 2}” polymorphs, and such motif plays a key role in achieving strong magnetic anisotropy. Boron atoms were found to be able to substitute cobalt atoms or occupy the “interruption” sites. First-principles calculations showed that the magnetocrystalline anisotropy energies of the boron-doped alloys are close to that of the high-temperature rhombohedral Co{sub 5}Zr phase and larger than that of the low-temperature Co{sub 5.25}Zr phase. Our calculations provide useful guidelines for further experimental optimization of the magnetic performances of these alloys.

  9. Study on magnetic separation for decontamination of cesium contaminated soil by using superconducting magnet

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, Susumu, E-mail: igarashi@qb.see.eng.osaka-u.ac.jp; Nomura, Naoki; Mishima, Fumihito; Akiyama, Yoko, E-mail: yoko-ak@see.eng.osaka-u.ac.jp

    2014-09-15

    Highlights: • The method for the soil decontamination by the superconducting magnet is proposed. • Magnetic separation of clay minerals was performed by HGMS. • Soil separation ratio was evaluated by quantitative analysis using XRD. • It is expected that HGMS can be applied to the actual soil decontamination. - Abstract: The accident of Fukushima Daiichi nuclear power plant caused the diffusion of radioactive cesium over the wide area. We examined the possibility of applying magnetic separation method using the superconducting magnet, which can process a large amount of the soil in high speed, to the soil decontamination and volume reduction of the radioactive cesium contaminated soil. Clay minerals are classified as 2:1 and 1:1 types by the difference of their layer structures, and these types of minerals are respectively paramagnetic and diamagnetic including some exception. It is known that most of the radioactive cesium is strongly adsorbed on the clay, especially on 2:1 type clay minerals. It is expected that the method which can separate only 2:1 type clay minerals selectively from the mixture clay minerals can enormously contribute to the volume reduction of the contaminated soil. In this study, the components in the clay before and after separation were evaluated to estimate the magnetic separation efficiency by using X-ray diffraction. From the results, the decontamination efficiency and the volume reduction ratio were estimated in order to examine the appropriate separation conditions for the practical decontamination of the soil.

  10. Effects of topography on the local variation in the magnetization of ultrasoft magnetic films : a Lorentz microscopy study

    NARCIS (Netherlands)

    Chechenin, NG; De Hosson, JTM; Boerma, DO

    2003-01-01

    This paper concentrates on a detailed analysis of Lorentz transmission electron microscopy (LTEM) observations in the study of the magnetic properties of soft magnetic films. Besides ripple fringes in the LTEM image that are commonly observed in nanocrystalline soft magnetic films, there also appear

  11. (Fundamental studies of new magnetic heterostructures: Their growth, crystallographic structure, magnetic and electronic properties)

    Energy Technology Data Exchange (ETDEWEB)

    Onellion, M. (Wisconsin Univ., Madison, WI (USA). Dept. of Physics); Dowben, P.A. (Syracuse Univ., NY (USA). Dept. of Physics)

    1990-01-01

    As part of our request for renewal of our grant, we include this progress report on the significant results obtained under grant number FG02-89ER45319, Fundamental Studies of New Magnetic Heterostructures: Their Growth, Crystallographic Structure, Magnetic and Electronic Properties,'' since the inception of the grant. The results include the scientific accomplishments, the instrumentation developed, and the technological applications of our work. Each area is discussed separately and an initial summary of all areas is provided before the detailed discussion.

  12. A Study of Neutron Star Structure in Strong Magnetic Fields that includes Anomalous Magnetic Moments

    Institute of Scientific and Technical Information of China (English)

    Guang-Jun Mao; Akira Iwamoto; Zhu-Xia Li

    2003-01-01

    We study the effect of strong magnetic fields on the structure of neutronstar. We find that if the interior field is on the same order as the surface fieldcurrently observed, then the influences of the field on the star's mass and radius arenegligible; if the field is as large as that estimated from the scalar virial theorem,then considerable effects will be induced. The maximum mass of the star will beincreased substantially while the central density is greatly reduced. The radius ofa magnetic star can be larger by about 10% ~ 20% than a nonmagnetic star of thesame mass.

  13. Magnetic Resonance Imaging Studies of Postpartum Depression: An Overview

    Directory of Open Access Journals (Sweden)

    Marco Fiorelli

    2015-01-01

    Full Text Available Postpartum depression is a frequent and disabling condition whose pathophysiology is still unclear. In recent years, the study of the neural correlates of mental disorders has been increasingly approached using magnetic resonance techniques. In this review we synthesize the results from studies on postpartum depression in the context of structural, functional, and spectroscopic magnetic resonance studies of major depression as a whole. Compared to the relative wealth of data available for major depression, magnetic resonance studies of postpartum depression are limited in number and design. A systematic literature search yielded only eleven studies conducted on about one hundred mothers with postpartum depression overall. Brain magnetic resonance findings in postpartum depression appear to replicate those obtained in major depression, with minor deviations that are not sufficient to delineate a distinct neurobiological profile for this condition, due to the small samples used and the lack of direct comparisons with subjects with major depression. However, it seems reasonable to expect that studies conducted in larger populations, and using a larger variety of brain magnetic resonance techniques than has been done so far, might allow for the identification of neuroimaging signatures for postpartum depression.

  14. Monte Carlo study of half-magnetization plateau and magnetic phase diagram in pyrochlore antiferromagnetic Heisenberg model

    OpenAIRE

    Motome, Yukitoshi; Penc, Karlo; Shannon, Nic

    2005-01-01

    The antiferromagnetic Heisenberg model on a pyrochlore lattice under external magnetic field is studied by classical Monte Carlo simulation. The model includes bilinear and biquadratic interactions; the latter effectively describes the coupling to lattice distortions. The magnetization process shows a half-magnetization plateau at low temperatures, accompanied with strong suppression of the magnetic susceptibility. Temperature dependence of the plateau behavior is clarified. Finite-temperatur...

  15. ADX: a high field, high power density, Advanced Divertor test eXperiment

    Science.gov (United States)

    Vieira, R.; Labombard, B.; Marmar, E.; Irby, J.; Shiraiwa, S.; Terry, J.; Wallace, G.; Whyte, D. G.; Wolfe, S.; Wukitch, S.; ADX Team

    2014-10-01

    The MIT PSFC and collaborators are proposing an advanced divertor experiment (ADX) - a tokamak specifically designed to address critical gaps in the world fusion research program on the pathway to FNSF/DEMO. This high field (6.5 tesla, 1.5 MA), high power density (P/S ~ 1.5 MW/m2) facility would utilize Alcator magnet technology to test innovative divertor concepts for next-step DT fusion devices (FNSF, DEMO) at reactor-level boundary plasma pressures and parallel heat flux densities while producing high performance core plasma conditions. The experimental platform would also test advanced lower hybrid current drive (LHCD) and ion-cyclotron range of frequency (ICRF) actuators and wave physics at the plasma densities and magnetic field strengths of a DEMO, with the unique ability to deploy launcher structures both on the low-magnetic-field side and the high-field side - a location where energetic plasma-material interactions can be controlled and wave physics is most favorable for efficient current drive, heating and flow drive. This innovative experiment would perform plasma science and technology R&D necessary to inform the conceptual development and accelerate the readiness-for-deployment of FNSF/DEMO - in a timely manner, on a cost-effective research platform. Supported by DE-FC02-99ER54512.

  16. Large field-induced irreversibility in Ni-Mn based Heusler shape-memory alloys: A pulsed magnetic field study

    Science.gov (United States)

    Nayak, A. K.; Mejia, C. Salazar; D'Souza, S. W.; Chadov, S.; Skourski, Y.; Felser, C.; Nicklas, M.

    2014-12-01

    We present a pulsed magnetic field study on the magnetic and magnetostriction properties of Ni-Mn-Z (Z =In , Sn, and Sb) based Heusler shape-memory alloys. These materials generally display a field-induced magnetostructural transition that could lead to an irreversible phase transition, when measured near the martensitic transition temperature. Here, we show that independently of the transition temperature, the critical field for the phase transition sensitively depends on the main-group element in the sample. Irrespective of their compositions, all samples display a magnetization of around 2 μB/f .u . in the martensite phase and about 6 μB/f .u . in the cubic austenite phase. Our magnetic and magnetostriction measurements at low temperatures exhibit a partial or complete arrest of the high-field austenite phase below the reverse martensitic transition. This results in a large irreversibility with a hysteresis width as high as 24 T. We introduce a theoretical model to discuss the experimental results.

  17. Lattice Field Theory Study of Magnetic Catalysis in Graphene

    CERN Document Server

    DeTar, Carleton; Zafeiropoulos, Savvas

    2016-01-01

    We discuss the simulation of the low-energy effective field theory (EFT) for graphene in the presence of an external magnetic field. Our fully nonperturbative calculation uses methods of lattice gauge theory to study the theory using a hybrid Monte Carlo approach. We investigate the phenomenon of magnetic catalysis in the context of graphene by studying the chiral condensate which is the order parameter characterizing the spontaneous breaking of chiral symmetry. In the EFT, the symmetry breaking pattern is given by $U(4) \\to U(2) \\times U(2)$. We also comment on the difficulty, in this lattice formalism, of studying the time-reversal-odd condensate characterizing the ground state in the presence of a magnetic field. Finally, we study the mass spectrum of the theory, in particular the Nambu-Goldstone (NG) mode as well as the Dirac quasiparticle, which is predicted to obtain a dynamical mass.

  18. Observation of Thermoelectric Currents in High-Field Superconductor-Ferromagnet Tunnel Junctions.

    Science.gov (United States)

    Kolenda, S; Wolf, M J; Beckmann, D

    2016-03-01

    We report on the experimental observation of spin-dependent thermoelectric currents in superconductor-ferromagnet tunnel junctions in high magnetic fields. The thermoelectric signals are due to a spin-dependent lifting of the particle-hole symmetry, and are found to be in excellent agreement with recent theoretical predictions. The maximum Seebeck coefficient inferred from the data is about -100  μV/K, much larger than commonly found in metallic structures. Our results directly prove the coupling of spin and heat transport in high-field superconductors.

  19. High-Field Faraday Effect of Tb-Doped Glass Above Paramagnetic Saturation

    Science.gov (United States)

    Chiba, Yoshiaki; Hori, Hidenobu; Yonenobu, Kenji; Yamagishi, Akio; Date, Muneyuki

    1987-08-01

    High-field Faraday effect is investigated in Tb-doped glass under a pulsed high magnetic field up to 40 tesla(T). The nonlinear Faraday effect due to saturation of the paramagnetic moment appears below about 20 T at 4.2 K. A considerably large Faraday rotation with the Verdet constant of -45.0 rad. T-1 m-1 is found above the paramagnetic saturation field, and this is explained by the field-induced level mixing in the multiplet levels.

  20. Studies on Magnetization Technique of High Temperature Superconductors

    OpenAIRE

    大橋, 忠巌; 荻原, 宏康

    1999-01-01

    It is known that permanent magnets produce magnetic fields up to 1T. On the other hand, magnetized high temperature superconductors can be used as "super"-permanent magnets which produce magnetic fields higher than 1T, because superconductors can trap higher magnetic fluxes than usual permanent magnets. In order to magnetize a YBCO bulk superconductor, there are two ways; a field cooling (FC) method and a zero field cooling (ZFC) method. FC is the way of magnetizing the superconductor by appl...

  1. A preliminary magnetic study of Sawa lake sediments, Southern Iraq

    Science.gov (United States)

    Ameen, Nawrass

    2016-04-01

    A preliminary magnetic study combined with chemical analyses was carried out in Sawa Lake in Al-Muthanna province, southern Iraq, about 22 km south west of Samawa city (31°18'48.80"N, 45°0'25.25"E). The lake is about 4.74 km length, 1.75 km width and 5.5 m height, it is surrounded by a salt rim which is higher than the lake water by about 2.8 m and sea water by about 18.5 m (Naqash et al., 1977 in Hassan, 2007). The lake is an elongated closed basin with no surface water available to it, it may be fed by groundwater of the Euphrates and Dammam aquifers through system of joints and cracks. This study aims to investigate the concentrations of selected heavy metals as pollutants and magnetic susceptibility (MS) and other magnetic properties of sediment samples from fifty sites collected from the bottom of the lake, the study area lies in an industrial area. The results show spatial variations of MS with mean value of about 4.58 x 10-8 m3 kg-1. Scanning electron microscopy and magnetic mineralogy parameters indicate the dominance of soft magnetic phase like magnetite and presence of hard magnetic phase like hematite. Spatial variations of MS combined with the concentrations of heavy metals suggests the efficiency of magnetic methods as effective, inexpensive and non-time consuming method to outlining the heavy metal pollution. References: Hassan W.F., 2007. The Physio-chemical characteristic of Sawa lake water in Samawa city-Iraq. Marine Mesopotamica, 22(2), 167-179.

  2. High field transport properties of a bilayer graphene

    Science.gov (United States)

    Bhargavi, K. S.; Kubakaddi, S. S.

    2014-02-01

    The high electric field transport properties namely, hot electron energy loss rate P, momentum loss rate Q, electron temperature Te and drift velocity Vd are studied theoretically in a bilayer graphene (BLG) by employing the momentum and energy balance technique. P and Q are investigated as a function of Te by considering the electron interaction with the acoustic phonons (APs) and the surface polar phonons (SPPs). In the Bloch-Grüneisen regime P (Q) due to APs is ~Te4 (Te2.5), with a new feature of a kink appearing due to the chiral nature of the electrons. The predicted Te4 is consistent with the recent experimental observation of heat resistance (Yan et al. Nature Nanotechnology 3 (2012) 472 [35]). Hot phonon effect is taken into account for SPPs. A dip has been observed in the hot phonon distribution of SPPs, a new feature, which is not found in conventional two-dimensional electron gas, and this can be attributed to the chiral nature of the electrons. P (Q) due to SPPs is found to be dominant at about Te>150 (180) K for a lattice temperature T=4.2 K. It is observed that the hot phonon effect is found to reduce P and Q due to SPPs significantly. Te and Vd are calculated as a function of the electric field E by taking into account the additional channels for momentum relaxation due to Coulomb impurity (CI) and short-range disorder (SD). Te is found to increase with the increasing electric field and is significantly enhanced by the hot phonon effect. Low field Vd is found to be limited by CI, SD and APs and in the high field region it reaches a near saturation value. The hot phonon effect tends to reduce the value of Vd. The presence of disorders CI and SD reduces Vd significantly and in clean samples larger saturation velocity can be achieved at a relatively smaller E.

  3. Conceptual design study of the K-DEMO magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keeman, E-mail: kkeeman@nfri.re.kr [National Fusion Research Institute, 169-148 Gwahak-ro, Daejeon 305-806 (Korea, Republic of); Oh, Sangjun; Park, Jong Sung; Lee, Chulhee; Im, Kihak; Kim, Hyung Chan; Lee, Gyung-Su [National Fusion Research Institute, 169-148 Gwahak-ro, Daejeon 305-806 (Korea, Republic of); Neilson, George; Brown, Thomas; Kessel, Charles; Titus, Peter; Zhai, Yuhu [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States)

    2015-10-15

    Highlights: • Perform a preliminary conceptual study for a steady-state Korean DEMO reactor. • Present a preliminary design of TF (toroidal field) magnet. • Present a preliminary design of CS (central solenoid) magnet. • Present a preliminary design of PF (toroidal field) magnet. - Abstract: As the ITER is being constructed, there is a growing anticipation for an earlier realization of fusion energy. A major design philosophy for the initiated conceptual design study for a steady-state Korean fusion demonstration reactor (K-DEMO) is engineering feasibility. A two-staged development plan is envisaged. K-DEMO is designed not only to demonstrate a net electricity generation and a self-sustained tritium cycle, but also to be used, in its initial stage, as a component test facility. Then, in its second stage, a major upgrade is carried out by replacing in-vessel components in order to show a net electricity generation on the order of 500 MWe. After a thorough 0-D system analysis, the major radius and minor radius are chosen to be 6.8 m and 2.1 m, respectively. In order to minimize wave deflection, a top-launch high frequency (>200 GHz) electron cyclotron current drive (ECCD) system will be the key system for the current profile control. For matching the high frequency ECCD, a high toroidal field (TF) is required and can be achieved by using high current density Nb{sub 3}Sn superconducting conductor. The peak magnetic field reaches to 16 T with the magnetic field at the plasma center above 7 T. Key features of the K-DEMO magnet system include the use of two TF coil winding packs, each of a different conductor design, to reduce the construction cost and save the space for the magnet structure material.

  4. Study of flow fractionation characteristics of magnetic chromatography utilizing high-temperature superconducting bulk magnet

    Directory of Open Access Journals (Sweden)

    Satoshi Fukui, Yoshihiro Shoji, Jun Ogawa, Tetsuo Oka, Mitsugi Yamaguchi, Takao Sato, Manabu Ooizumi, Hiroshi Imaizumi and Takeshi Ohara

    2009-01-01

    Full Text Available We present numerical simulation of separating magnetic particles with different magnetic susceptibilities by magnetic chromatography using a high-temperature superconducting bulk magnet. The transient transport is numerically simulated for two kinds of particles having different magnetic susceptibilities. The time evolutions were calculated for the particle concentration in the narrow channel of the spiral arrangement placed in the magnetic field. The field is produced by the highly magnetized high-temperature superconducting bulk magnet. The numerical results show the flow velocity difference of the particle transport corresponding to the difference in the magnetic susceptibility, as well as the possible separation of paramagnetic particles of 20 nm diameter.

  5. Low temperature Mössbauer studies on magnetic nanocomposites

    Indian Academy of Sciences (India)

    K A Malini; M R Anantharaman; Ajay Gupta

    2004-08-01

    Nanocomposites with magnetic components possessing nanometric dimensions, lying in the range 1–10 nm, are found to be exhibiting superior physical properties with respect to their coarser sized counterparts. Magnetic nanocomposites based on gamma iron oxide embedded in a polymer matrix have been prepared and characterized. The behaviour of these samples at low temperatures have been studied using Mössbauer spectroscopy. Mössbauer studies indicate that the composites consist of very fine particles of -Fe2O3 of which some amount exists in the superparamagnetic phase. The cycling of the preparative conditions were found to increase the amount of -Fe2O3 in the matrix.

  6. The study of magnetic reconnection in solar spicules

    CERN Document Server

    Fazel, Z

    2014-01-01

    This work is devoted to study the magnetic reconnection instability under solar spicule conditions. Numerical study of the resistive tearing instability in a current sheet is presented by considering the magnetohydrodynamic (MHD) framework. To investigate the effect of this instability in a stratified atmosphere of solar spicules, we solve linear and non-ideal MHD equations in the x-z plane. In the linear analysis it is assumed that resistivity is only important within the current sheet, and the exponential growth of energies takes place faster as plasma resistivity increases. We are interested to see the occurrence of magnetic reconnection during the lifetime of a typical solar spicule.

  7. The use of amorphous boron powder enhances mechanical alloying in soft magnetic FeNbB alloy: A magnetic study

    Energy Technology Data Exchange (ETDEWEB)

    Ipus, J. J.; Blazquez, J. S.; Franco, V.; Conde, A. [Dpto. Fisica de la Materia Condensada, ICMSE-CSIC, Universidad de Sevilla, P.O. Box 1065, 41080 Sevilla (Spain)

    2013-05-07

    Saturation magnetization and magnetic anisotropy have been studied during mechanical alloying of Fe{sub 75}Nb{sub 10}B{sub 15} alloys prepared using crystalline and commercial amorphous boron. The evolution of saturation magnetization indicates a more efficient dissolution of boron into the matrix using amorphous boron, particularly for short milling times. The magnetization of the crystalline phase increases as boron is incorporated into this phase. Two milling time regimes can be used to describe the evolution of magnetic anisotropy: a first regime governed by microstrains and a second one mainly governed by crystal size and amorphous fraction.

  8. MAGNET

    CERN Multimedia

    by B. Curé

    2011-01-01

    The magnet operation was very satisfactory till the technical stop at the end of the year 2010. The field was ramped down on 5th December 2010, following the successful regeneration test of the turbine filters at full field on 3rd December 2010. This will limit in the future the quantity of magnet cycles, as it is no longer necessary to ramp down the magnet for this type of intervention. This is made possible by the use of the spare liquid Helium volume to cool the magnet while turbines 1 and 2 are stopped, leaving only the third turbine in operation. This obviously requires full availability of the operators to supervise the operation, as it is not automated. The cryogenics was stopped on 6th December 2010 and the magnet was left without cooling until 18th January 2011, when the cryoplant operation resumed. The magnet temperature reached 93 K. The maintenance of the vacuum pumping was done immediately after the magnet stop, when the magnet was still at very low temperature. Only the vacuum pumping of the ma...

  9. Magnetic study on biodistribution and biodegradation of oral magnetic nanostructures in the rat gastrointestinal tract.

    Science.gov (United States)

    Martín, Miguel; Rodríguez-Nogales, Alba; Garcés, Víctor; Gálvez, Natividad; Gutiérrez, Lucía; Gálvez, Julio; Rondón, Deyanira; Olivares, Mónica; Dominguez-Vera, Jose M

    2016-08-11

    We have undertaken a magnetic study on the oral biodistribution and biodegradation of nude maghemite nanoparticles of 10 nm average size (MNP) and probiotic bacteria, Lactobacillus fermentum, containing thousands of these same nanoparticles (MNP-bacteria). Using AC magnetic susceptibility measurements of the stomach, small intestine, cecum and large intestine obtained after rat sacrifice, and iron content determination by ICP-OES, we have monitored the biodistribution and biodegradation of the maghemite nanoparticles along the gastrointestinal tract, after oral administration of both MNP and MNP-bacteria. The results revealed that the amount of magnetic nanoparticles accumulated in intestines is sensibly higher when MNP-bacteria were administered, in comparison with MNP. This confirms our initial hypothesis that the use of probiotic bacteria is a suitable strategy to assist the magnetic nanoparticles to overcome the stomach medium, and to achieve their accumulation in intestines. This finding opens doors to different applications. Since iron absorption in humans takes place precisely in the intestines, the use of MNP-bacteria as an iron supplement is a definite possibility. We have actually illustrated how the administration of MNP-bacteria to iron-deficient rats corrects the iron levels after two weeks of treatment.

  10. Hyperfine coupling constant for {sup 59}Co estimated from a high-field susceptibility and high-field NMR shift in ferromagnetic Co{sub 2}TiGa and Co{sub 2}VGa

    Energy Technology Data Exchange (ETDEWEB)

    Nishihara, H; Furutani, Y; Wada, T [Faculty of Science and Technology, Ryukoku University, Otsu 520-2194 (Japan); Kanomata, T [Faculty of Engineering, Tohoku Gakuin University, Tagajo 985-8537 (Japan); Kobayashi, K; Ishida, K [Graduate School of Engineering, Tohoku University, Sendai 980-8579 (Japan); Kainuma, R [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Koyama, K; Watanabe, K, E-mail: nishihara@rins.ryukoku.ac.j [Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan)

    2010-01-01

    The hyperfine coupling constant for {sup 59}Co in the ferromagnetic state of a Heusler alloy Co{sub 2}TiGa in the high-field range has been estimated to be 170 kOe per 1 {mu}{sub B} of the moment of cobalt atom from the high-field magnetic susceptibility of 2.3 x 10{sup -6} emu/gOe measured at 5 K in a field range from 20 to 70 kOe and a reported positive high-field NMR shift of +0.83 percent. The value of the hyperfine coupling constant has been found to be even larger in the case of Co{sub 2}VGa. These features suggest that the positive hyperfine field at Co nucleus in the Co-based Heusler alloys is due to conduction electron polarization rather than a transferred hyperfine field.

  11. A carbon-13 and proton nuclear magnetic resonance study of some experimental referee broadened-specification /ERBS/ turbine fuels

    Science.gov (United States)

    Dalling, D. K.; Pugmire, R. J.

    1982-01-01

    Preliminary results of a nuclear magnetic resonance (NMR) spectroscopy study of alternative jet fuels are presented. A referee broadened-specification (ERBS) aviation turbine fuel, a mixture of 65 percent traditional kerosene with 35 percent hydrotreated catalytic gas oil (HCGO) containing 12.8 percent hydrogen, and fuels of lower hydrogen content created by blending the latter with a mixture of HCGO and xylene bottoms were studied. The various samples were examined by carbon-13 and proton NMR at high field strength, and the resulting spectra are shown. In the proton spectrum of the 12.8 percent hydrogen fuel, no prominent single species is seen while for the blending stock, many individual lines are apparent. The ERBS fuels were fractionated by high-performance liquid chromatography and the resulting fractions analyzed by NMR. The species found are identified.

  12. Integration of ultra-high field MRI and histology for connectome based research of brain disorders

    Science.gov (United States)

    Yang, Shan; Yang, Zhengyi; Fischer, Karin; Zhong, Kai; Stadler, Jörg; Godenschweger, Frank; Steiner, Johann; Heinze, Hans-Jochen; Bernstein, Hans-Gert; Bogerts, Bernhard; Mawrin, Christian; Reutens, David C.; Speck, Oliver; Walter, Martin

    2013-01-01

    Ultra-high field magnetic resonance imaging (MRI) became increasingly relevant for in vivo neuroscientific research because of improved spatial resolutions. However, this is still the unchallenged domain of histological studies, which long played an important role in the investigation of neuropsychiatric disorders. While the field of biological psychiatry strongly advanced on macroscopic levels, current developments are rediscovering the richness of immunohistological information when attempting a multi-level systematic approach to brain function and dysfunction. For most studies, histology sections lost information on three-dimensional reconstructions. Translating histological sections to 3D-volumes would thus not only allow for multi-stain and multi-subject alignment in post mortem data, but also provide a crucial step in big data initiatives involving the network analyses currently performed with in vivo MRI. We therefore investigated potential pitfalls during integration of MR and histological information where no additional blockface information is available. We demonstrated that strengths and requirements from both methods can be effectively combined at a spatial resolution of 200 μm. However, the success of this approach is heavily dependent on choices of hardware, sequence and reconstruction. We provide a fully automated pipeline that optimizes histological 3D reconstructions, providing a potentially powerful solution not only for primary human post mortem research institutions in neuropsychiatric research, but also to help alleviate the massive workloads in neuroanatomical atlas initiatives. We further demonstrate (for the first time) the feasibility and quality of ultra-high spatial resolution (150 μm isotopic) imaging of the entire human brain MRI at 7T, offering new opportunities for analyses on MR-derived information. PMID:24098272

  13. Integration of ultra-high field MRI and histology for connectome based research of brain disorders

    Directory of Open Access Journals (Sweden)

    Shan eYang

    2013-09-01

    Full Text Available Ultra-high field magnetic resonance imaging (MRI became increasingly relevant for in vivo neuroscientific research because of improved spatial resolutions. However, this is still the unchallenged domain of histological studies, which long played an important role in the investigation of neuropsychiatric disorders. While the field of biological psychiatry strongly advanced on macroscopic levels, current developments are rediscovering the richness of immunohistological information when attempting a multi-level systematic approach to brain function and dysfunction. For most studies, histology sections lost information on three-dimensional reconstructions. Translating histological sections to 3D-volumes would thus not only allow for multi-stain and multi-subject alignment in post mortem data, but also provide a crucial step in big data initiatives involving the network analyses currently performed with in vivo MRI. We therefore investigated potential pitfalls during integration of MR and histological information where no additional blockface information is available. We demonstrated that strengths and requirements from both methods seem to be ideally merged at a spatial resolution of 200 μm. However, the success of this approach is heavily dependent on choices of hardware, sequence and reconstruction. We provide a fully automated pipeline that optimizes histological 3D reconstructions, providing a potentially powerful solution not only for primary human post mortem research institutions in neuropsychiatric research, but also to help alleviate the massive workloads in neuroanatomical atlas initiatives. We further demonstrate (for the first time the feasibility and quality of ultra-high spatial resolution (150 µm isotopic imaging of the entire human brain MRI at 7T, offering new opportunities for analyses on MR-derived information.

  14. Magnetism in Medicine

    Science.gov (United States)

    Schenck, John

    2000-03-01

    For centuries physicians, scientists and others have postulated an important role, either as a cause of disease or as a mode of therapy, for magnetism in medicine. Although there is a straightforward role in the removal of magnetic foreign bodies, the majority of the proposed magnetic applications have been controversial and have often been attributed by mainstream practitioners to fraud, quackery or self-deception. Calculations indicate that many of the proposed methods of action, e.g., the field-induced alignment of water molecules or alterations in blood flow, are of negligible magnitude. Nonetheless, even at the present time, the use of small surface magnets (magnetotherapy) to treat arthritis and similar diseases is a widespread form of folk medicine and is said to involve sales of approximately one billion dollars per year. Another medical application of magnetism associated with Mesmer and others (eventually known as animal magnetism) has been discredited, but has had a culturally significant role in the development of hypnotism and as one of the sources of modern psychotherapy. Over the last two decades, in marked contrast to previous applications of magnetism to medicine, magnetic resonance imaging or MRI, has become firmly established as a clinical diagnostic tool. MRI permits the non-invasive study of subtle biological processes in intact, living organisms and approximately 150,000,000 diagnostic studies have been performed since its clinical introduction in the early 1980s. The dramatically swift and widespread acceptance of MRI was made possible by scientific and engineering advances - including nuclear magnetic resonance, computer technology and whole-body-sized, high field superconducting magnets - in the decades following World War Two. Although presently used much less than MRI, additional applications, including nerve and muscle stimulation by pulsed magnetic fields, the use of magnetic forces to guide surgical instruments, and imaging utilizing

  15. The primary motor area for voluntary diaphragmatic motion identified by high field fMRI.

    Science.gov (United States)

    Nakayama, Takahiro; Fujii, Yukihiko; Suzuki, Kiyotaka; Kanazawa, Ichiro; Nakada, Tsutomu

    2004-06-01

    In order to identify the precise location of the primary motor area for the diaphragm with respect to the classical motor homunculus, functional magnetic resonance imaging (fMRI) experiments were performed utilizing independent component-cross correlation- sequential epoch (ICS) analysis on a high-field (3.0 Tesla) system. Activations which correlated with voluntary diaphragmatic motion mapped onto the area anterolateral to that for voluntary hand motion (internal control in ICS analysis). Multiple subject analysis yielded the primary motor cortex for the diaphragm to be (+/-48, -4, 47) in the Talairach and Tournoux coordinates. The results were highly consistent with the previously reported cortical area for the diaphragm determined by transcranial electrical/magnetic stimulation.

  16. Magnetic resonance imaging study of corpus callosum ...

    African Journals Online (AJOL)

    2014-11-02

    Nov 2, 2014 ... gender and callosal measures in patient and control groups. In all groups of ..... our intelligence and problem-solving ability. The prefrontal cortex plays a role in the regulation of complex cognitive, emotional and .... in the corpus callosum in abuse-related posttraumatic stress disorder: A preliminary study. J.

  17. First-principles insights into f magnetism: A case study on some magnetic pyrochlores

    Science.gov (United States)

    Deilynazar, Najmeh; Khorasani, Elham; Alaei, Mojtaba; Javad Hashemifar, S.

    2015-11-01

    First-principles calculations are performed to investigate f magnetism in A2Ti2O7 (A=Eu, Gd, Tb, Dy, Ho, Er, Yb) magnetic pyrochlore oxides. The Hubbard U parameter and the relativistic spin orbit correction are applied for a more accurate description of the electronic structure of the systems. It is argued that the main obstacle for the first-principles study of these systems is the multi-minima solutions of their electronic configuration. Among the studied pyrochlores, Gd2Ti2O7 shows the least multi-minima problem. The crystal electric field theory is applied for phenomenological comparison of the calculated spin and orbital moments with the experimental data.

  18. Electron Paramagnetic Studies Of Diluted Magnetic Semiconductor Nanostructures

    CERN Document Server

    Montes, L A

    1999-01-01

    In this thesis we investigate the Electron Paramagnetic Resonance (EPR) of Diluted Magnetic Semiconductor (DMS) nanostructures. The first chapter studies the appearance of strain-induced magnetic dipole forbidden transitions in the EPR spectrum of highly mismatched DMS superlattices grown by Molecular Beam Epitaxy (MBE). We investigated ZnTe/MnTe, ZnTe/CdTe:Mn and CdTe/ZnTe:Mn superlattices where the lattice mismatch between layers reaches values as large as 6%. We report the appearance of forbidden transitions even at orientations where strain should not produce any mixing, and interpret them as the onset of three dimensional growth of Quantum Dots (QD)...

  19. Study of quench propagation velocity in superconducting magnets for UNK

    Energy Technology Data Exchange (ETDEWEB)

    Bogdanov, I.V.; Sheherbakov, P.A.; Snitko, V.P.; Tkachenko, N.P.; Vasiliev, L.M.; Vybornov, M.G.; Ziobin, A.V.

    1989-03-01

    Two superconducting magnet models, warm-iron and cold-iron designs are studied within the frames of work on UNK. The present note describes the method and results on measuring quench propagation velocity in the superconducting cables with a transport current in external field under the cooling conditions typical for those of the magnet winding. The results on measuring quench propagation velocities in warm-iron and cold-iron designs are presented. The results obtained for short samples and model coils are compared.

  20. Measurement of the inductance of resistive magnets: two case studies

    CERN Document Server

    Buzio, M; Giloteaux, D

    2011-01-01

    This note concerns the main definitions of self-inductance (i.e. differential, secant and energy-based) that are relevant for the electromagnetic modelling of accelerator magnets. In particular, we consider the case of iron-dominated resistive magnets. The different definitions, which coincide in the linear limit at low field, tend to diverge dramatically as the iron becomes saturated. We describe the measurement technique and the results for two case studies, i.e. the PS MTE octupole and a main SPS dipole of MBB type. We show that the differential inductance may drop dramatically at high current, up to about a factor two, even for magnets where the field non linearity is within a few percent only.

  1. Magnetic Flux Expulsion Studies in Niobium SRF Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Posen, Sam [Fermilab; Checchin, Mattia [Fermilab; Crawford, Anthony [Fermilab; Grassellino, Anna [Fermilab; Martinello, Martina [Fermilab; Melnychuk, Oleksandr [Fermilab; Romanenko, Alexander [Fermilab; Sergatskov, Dmitri [Fermilab; Trenikhina, Yulia [Fermilab

    2016-06-01

    With the recent discovery of nitrogen doping treatment for SRF cavities, ultra-high quality factors at medium accelerating fields are regularly achieved in vertical RF tests. To preserve these quality factors into the cryomodule, it is important to consider background magnetic fields, which can become trapped in the surface of the cavity during cooldown and cause Q₀ degradation. Building on the recent discovery that spatial thermal gradients during cooldown can significantly improve expulsion of magnetic flux, a detailed study was performed of flux expulsion on two cavities with different furnace treatments that are cooled in magnetic fields amplitudes representative of what is expected in a realistic cryomodule. In this contribution, we summarize these cavity results, in order to improve understanding of the impact of flux expulsion on cavity performance.

  2. Study of some parameters interstellar transport using of magnetic umbrella

    CERN Document Server

    Čermák, Martin

    2013-01-01

    Interstellar transport is an object of interest in many sci-fi stories. In history a lot of sci-fi predictions have turned into reality, such as communications satellites, deep-sea submarines and journies to the moon. In this work we study some physical parameters of a space ship which uses a magnetic umbrella. Our spaceship generates a magnetic field in its neighborhood and captures charged protons into a magnetic trap. These particles are taken into a fusion reactor. The obtained energy and waste in form of helium are used as a fuel in an ion engine. With the help of elementary physics we can work out the basic physical parameters of the ship, e.g. maximal velocity, acceleration of the ship or acceleration time period.

  3. Low-field MRI can be more sensitive than high-field MRI

    Science.gov (United States)

    Coffey, Aaron M.; Truong, Milton L.; Chekmenev, Eduard Y.

    2013-12-01

    MRI signal-to-noise ratio (SNR) is the key factor for image quality. Conventionally, SNR is proportional to nuclear spin polarization, which scales linearly with magnetic field strength. Yet ever-stronger magnets present numerous technical and financial limitations. Low-field MRI can mitigate these constraints with equivalent SNR from non-equilibrium ‘hyperpolarization' schemes, which increase polarization by orders of magnitude independently of the magnetic field. Here, theory and experimental validation demonstrate that combination of field independent polarization (e.g. hyperpolarization) with frequency optimized MRI detection coils (i.e. multi-turn coils using the maximum allowed conductor length) results in low-field MRI sensitivity approaching and even rivaling that of high-field MRI. Four read-out frequencies were tested using samples with identical numbers of 1H and 13C spins. Experimental SNRs at 0.0475 T were ∼40% of those obtained at 4.7 T. Conservatively, theoretical SNRs at 0.0475 T 1.13-fold higher than those at 4.7 T were possible despite an ∼100-fold lower detection frequency, indicating feasibility of high-sensitivity MRI without technically challenging, expensive high-field magnets. The data at 4.7 T and 0.0475 T was obtained from different spectrometers with different RF probes. The SNR comparison between the two field strengths accounted for many differences in parameters such as system noise figures and variations in the probe detection coils including Q factors and coil diameters.

  4. High-field thermal transports properties of REBCO coated conductors

    CERN Document Server

    Bonura, M

    2015-01-01

    The use of REBCO coated conductors is envisaged for many applications, extending from power cables to high-field magnets. Whatever the case, thermal properties of REBCO tapes play a key role for the stability of superconducting devices. In this work, we present the first study on the longitudinal thermal conductivity (k) of REBCO coated conductors in magnetic fields up to 19 T applied both parallelly and perpendicularly to the thermal-current direction. Copper-stabilized tapes from six industrial manufacturers have been investigated. We show that zero-field k of coated conductors can be calculated with an accuracy of ‡ 15% from the residual resistivity ratio of the stabilizer and the Cu/non-Cu ratio. Measurements performed at high fields have allowed us to evaluate the consistency of the procedures generally used for estimating in-field k in the framework of the Wiedemann-Franz law from an electrical characterization of the materials. In-field data are intended to provide primary ingredients for the ...

  5. Magnetic Resonance Perfusion Imaging in the Study of Language

    Science.gov (United States)

    Hillis, Argye E.

    2007-01-01

    This paper provides a brief review of various uses of magnetic resonance perfusion imaging in the investigation of brain/language relationships. The reviewed studies illustrate how perfusion imaging can reveal areas of brain where dysfunction due to low blood flow is associated with specific language deficits, and where restoration of blood flow…

  6. Surface magnetism studied by polarized light emission after He+ scattering

    NARCIS (Netherlands)

    Manske, J; Dirska, M; Lubinski, G; Schleberger, M; Narmann, A; Hoekstra, R

    1997-01-01

    Surface magnetism is studied by means of an ion beam of low energy (2-15 keV) scattered off the surface under grazing incidence conditions. During the scattering, a small fraction of the ions is neutralized into excited states which decay subsequently by light emission. The circular polarization of

  7. Development of high-pressure, high-field and multifrequency electron spin resonance system.

    Science.gov (United States)

    Sakurai, T; Taketani, A; Tomita, T; Okubo, S; Ohta, H; Uwatoko, Y

    2007-06-01

    The electron spin resonance (ESR) system which covers the magnetic field region up to 16 T, the quasicontinuous frequency region from 60 to 700 GHz, the temperature region from 1.8 to 4.2 K, and the hydrostatic pressure region up to 1.1 GPa has been developed. This is the first pulsed high-field and multifrequency ESR system with the pressure region over 1 GPa as far as we know. Transmission ESR spectra under hydrostatic pressure can be obtained by combining a piston-cylinder-type pressure cell and the pulsed magnetic field ESR apparatus. The pressure cell consists of a NiCrAl cylinder and sapphire or zirconia inner parts. The use of sapphire or zirconia as inner parts enables us to observe ESR under pressure because these inner parts have high transmittance for the electromagnetic wave with millimeter and submillimeter wavelengths. We have successfully applied this system for the pressure dependence measurements of an isolated spin system NiSnCl(6)6H(2)O up to 1.1 GPa. It was found that the single ion anisotropy parameter D of this compound strongly depends on pressure. The parameter D is approximately proportional to the pressure up to 0.75 GPa, and the relation between D and the pressure can be used for the pressure calibration of this high-field and high-pressure ESR system.

  8. A method to assess the loss of a dipole antenna for ultra-high-field MRI.

    Science.gov (United States)

    Chen, Gang; Collins, Christopher M; Sodickson, Daniel K; Wiggins, Graham C

    2017-06-19

    To describe a new bench measurement based on quality (Q) factors to estimate the coil noise relative to the sample noise of dipole antennas at 7 T. Placing a dipole antenna close to a highly conductive sample surrogate (HCSS) greatly reduces radiation loss, and using QHCSS gives a more accurate estimate of coil resistance than Qunloaded . Instead of using the ratio of unloaded and sample-loaded Q factors, the ratio of HCSS-loaded and sample-loaded Q factors should be used at ultra-high fields. A series of simulations were carried out to analyze the power budget of sample-loaded or HCSS-loaded dipole antennas. Two prototype dipole antennas were also constructed for bench measurements to validate the simulations. Simulations showed that radiation loss was suppressed when the dipole antenna was HCSS-loaded, and coil loss was largely the same as when the dipole was loaded by the sample. Bench measurements also showed good alignment with simulations. Using the ratio QHCSS /Qloaded gives a good estimate of the coil loss for dipole antennas at 7 T, and provides a convenient bench measurement to predict the body noise dominance of dipole antenna designs. The new approach also applies to conventional surface loop coils at ultra-high fields. Magn Reson Med 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  9. High-field magnetotransport in microstructures of the frustrated antiferromagnet Yb2Pt2Pb

    Energy Technology Data Exchange (ETDEWEB)

    Helm, T. [Max Planck Inst. for Chemical Physics, Dresden (Germany); Moll, P. J. W. [Max Planck Inst. for Chemical Physics, Dresden (Germany); Chan, Mun Keat [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ramshaw, Brad [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Balakirev, Fedor Fedorovich [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-06

    Frustrated quantum magnets exhibit a rich variety of non-trivial quantum ground states due to their remnant entropy at zero temperature. Most studied materials are insulators, with magnetic coupling of localized spins mediated by exchange interactions. Yb2Pt2Pb (YPP) is a rare example of a metallic frustrated quantum magnet, where Yb3+ J=7/2 moments are arranged in dimers forming a Shastry-Sutherland lattice. In addition, the itinerant charge carriers of the metal provide gapless excitations able to mediate magnetic interactions (RKKY) as well as hybridize with the 4f-states, which has been proposed to lead to a novel charge-orbital separation. YPP orders antiferromagnetically (AFM) below TN = 2.1 K, and strong g-factor anisotropy confines the spins into the ab planes. Accordingly, fields aligned parallel to the planes suppress the AFM order already below 4 T, while fields of up to 65 T along the c direction do not lead to saturation in the magnetization and step-like features even at B ~ 25 T were observed [4]. Here we probe the electronic structure of YPP by quantum oscillation and conductivity measurements in high fields, which tune the energy balance of the 4f states and thus the degree of charge-orbital separation.

  10. Cosmic ray decreases and magnetic clouds

    Energy Technology Data Exchange (ETDEWEB)

    Cane, H.V. (NASA Goddard Space Flight Center, Greenbelt, MD (United States))

    1993-03-01

    A study has been made of energetic particle data, obtained from IMP 8, in conjunction with solar wind field and plasma data at the times of reported magnetic clouds. It is shown that magnetic clouds can cause a depression of the cosmic ray flux but high fields are required. A depression of 3% in a neutron monitor requires a field of about 25 nT. Such high fields are found only in a subset of coronal ejecta. The principal cause for Forbush decreases associated with energetic shocks is probably turbulence in the postshock region, although some shocks will be followed by an ejecta with a high field. Each event is different. The lower-energy particles can help in identifying the dominant processes in individual events. 19 refs., 5 figs.

  11. High field optical nonlinearity and the Kramers-Kronig relations.

    Science.gov (United States)

    Wahlstrand, J K; Cheng, Y-H; Milchberg, H M

    2012-09-14

    The nonlinear optical response to high fields is absolutely measured for the noble gas atoms He, Ne, Ar, Kr, and Xe. We find that the response is quadratic in the laser field magnitude up to the ionization threshold of each gas. Its size and quadratic dependence are well predicted by a Kramers-Kronig analysis employing known ionization probabilities, and the results are consistent with calculations using the time-dependent Schrödinger equation.

  12. Magnetic

    Science.gov (United States)

    Aboud, Essam; El-Masry, Nabil; Qaddah, Atef; Alqahtani, Faisal; Moufti, Mohammed R. H.

    2015-06-01

    The Rahat volcanic field represents one of the widely distributed Cenozoic volcanic fields across the western regions of the Arabian Peninsula. Its human significance stems from the fact that its northern fringes, where the historical eruption of 1256 A.D. took place, are very close to the holy city of Al-Madinah Al-Monawarah. In the present work, we analyzed aeromagnetic data from the northern part of Rahat volcanic field as well as carried out a ground gravity survey. A joint interpretation and inversion of gravity and magnetic data were used to estimate the thickness of the lava flows, delineate the subsurface structures of the study area, and estimate the depth to basement using various geophysical methods, such as Tilt Derivative, Euler Deconvolution and 2D modeling inversion. Results indicated that the thickness of the lava flows in the study area ranges between 100 m (above Sea Level) at the eastern and western boundaries of Rahat Volcanic field and getting deeper at the middle as 300-500 m. It also showed that, major structural trend is in the NW direction (Red Sea trend) with some minor trends in EW direction.

  13. Hole-exciton interaction induced high field decay of magneto-electroluminescence in Alq{sub 3}-based organic light-emitting diodes at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tingting; Holford, D. F.; Gu, Hang; Kreouzis, T. [Materials Research Institute and School of Physics and Astronomy, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); Zhang, Sijie, E-mail: Sijie.zhang@scu.edu.cn, E-mail: w.gillin@qmul.ac.uk [College of Physical Science and Technology, Sichuan University, Chengdu 610064 (China); Gillin, W. P., E-mail: Sijie.zhang@scu.edu.cn, E-mail: w.gillin@qmul.ac.uk [Materials Research Institute and School of Physics and Astronomy, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); College of Physical Science and Technology, Sichuan University, Chengdu 610064 (China)

    2016-01-11

    The magnetic field effects on the electroluminescence of aluminium tris-(8-hydroxyqinoline) (Alq{sub 3}) based organic light emitting diodes have been investigated by varying the electron/hole ratio in the emissive layer. Experimental results reveal that a negative high field effect in the magneto-electroluminescence (MEL) can be found in devices with very low triplet exciton concentration at room temperature. This suggests triplet-triplet annihilation cannot be used to explain the negative high field MEL in the Alq{sub 3} system. Our results suggest that hole-exciton interaction may be the origin of the negative high field MEL and also, in parallel with this interaction, there is also the more common positive high field process occurring which has been tentatively attributed to electron-exciton interactions. The competition between these different processes decides the final shape of the MEL at high fields.

  14. Study of magnetic properties of graphene nanostructures and graphene nanoribbons

    Directory of Open Access Journals (Sweden)

    F Fazileh

    2012-03-01

    Full Text Available The discovery of graphene and its remarkable electronic and magnetic properties has initiated great research interest in this material. Furthermore, there are many derivatives in these graphene related materials among which graphene nanoribbons and graphene nanofragments are candidates for future carbon-based nanoelectronics and spintronics. Theoretical studies have shown that magnetism can arise in various situations such as point defects, disorder and reduced dimensionality. Using a mean field Hubbard model, we studied the appearance of magnetic textures in zero-dimensional graphene nanofragments and one-dimensional graphene zigzag nanoribbons. Among nanofragments, triangular shape, bowtie and coronene were studied. We explain how the shape of these materials, the imbalance in the number of atoms belonging to the graphene sublattices, the existence of zero-energy states and the total and local magnetic moments were related. At the end, we focused on the effects of a model disorder potential (Anderson-type, and illustrate how density of states of zigzag nanoribbons was affected.

  15. Studies on in situ magnetic alignment of bonded anisotropic Nd-Fe-B alloy powders

    Science.gov (United States)

    Nlebedim, I. C.; Ucar, Huseyin; Hatter, Christine B.; McCallum, R. W.; McCall, Scott K.; Kramer, M. J.; Paranthaman, M. Parans

    2017-01-01

    Considerations for achieving high degree of alignment in polymer bonded permanent magnets are presented via the results of a study on in situ magnetic alignment of anisotropic Nd-Fe-B magnet powders. Contributions from effect of the alignment temperature, alignment magnetic field and the properties of the polymer on the hard magnetic properties of the bonded magnet were considered. The thermo-rheological properties of the polymer and the response of the magnet powders to the applied magnetic field indicate that hard magnetic properties were optimized at an alignment temperature just above the melting temperature of the EVA co-polymer. This agrees with an observed correlation between the change in magnetization due to improved magnetic alignment of the anisotropic powders and the change in viscosity of the binder. Manufacturing cost can be minimized by identifying optimum alignment temperatures and magnetic field strengths.

  16. Magnetic force microscopy and simulation studies on Co$_{50}$Fe$_{50}$ elliptical nanomagnets

    Indian Academy of Sciences (India)

    N V S S SESHAGIRI RAO; V SATYA NARAYANA MURTHY; Y J V S RAMAKRISHNA SHARMA

    2016-06-01

    We studied the magnetization reversal mechanism of single-layered Co50Fe50 nanomagnets by measuring the magnetization reversal and using the micromagnetic simulations. The magnetization reversal strongly depends on the thickness of the nanomagnets. In the remanent state, the magnetic force microscopy studies and the simulation data showed the formation of single and vortex states depending on the thickness of nanomagnets.

  17. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet was energised at the beginning of March 2012 at a low current to check all the MSS safety chains. Then the magnet was ramped up to 3.8 T on 6 March 2012. Unfortunately two days later an unintentional switch OFF of the power converter caused a slow dump. This was due to a misunderstanding of the CCC (CERN Control Centre) concerning the procedure to apply for the CMS converter control according to the beam-mode status at that time. Following this event, the third one since 2009, a discussion was initiated to define possible improvement, not only on software and procedures in the CCC, but also to evaluate the possibility to upgrade the CMS hardware to prevent such discharge from occurring because of incorrect procedure implementations. The magnet operation itself was smooth, and no power cuts took place. As a result, the number of magnetic cycles was reduced to the minimum, with only two full magnetic cycles from 0 T to 3.8 T. Nevertheless the magnet suffered four stops of the cryogeni...

  18. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    Operation of the magnet has gone quite smoothly during the first half of this year. The magnet has been at 4.5K for the full period since January. There was an unplanned short stop due to the CERN-wide power outage on May 28th, which caused a slow dump of the magnet. Since this occurred just before a planned technical stop of the LHC, during which access in the experimental cavern was authorized, it was decided to leave the magnet OFF until 2nd June, when magnet was ramped up again to 3.8T. The magnet system experienced a fault also resulting in a slow dump on April 14th. This was triggered by a thermostat on a filter choke in the 20kA DC power converter. The threshold of this thermostat is 65°C. However, no variation in the water-cooling flow rate or temperature was observed. Vibration may have been the root cause of the fault. All the thermostats have been checked, together with the cables, connectors and the read out card. The tightening of the inductance fixations has also been checked. More tem...

  19. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  20. High magnetic field studies of AlGaN/GaN heterostructures grown on bulk GaN

    Energy Technology Data Exchange (ETDEWEB)

    Siekacz, M.; Nowak, G.; Porowski, S. [High Pressure Research Center, Polish Academy of Sciences, 01-142 Warsaw (Poland); Dybko, K. [Institute of Physics, Polish Academy of Sciences, 02-668 Warsaw (Poland); Skierbiszewski, C. [High Pressure Research Center, Polish Academy of Sciences, 01-142 Warsaw (Poland); TopGaN Ltd., Warsaw (Poland); Knap, W. [High Pressure Research Center, Polish Academy of Sciences, 01-142 Warsaw (Poland); GES -UMR, CNRS - Universite Montpellier 2, Place E. Bataillon, 34950 Montpellier (France); Wasilewski, Z. [Institute for Microstructural Sciences, National Research Council, Ottawa (Canada); Maude, D. [Grenoble High Magnetic Field Laboratory, MPI-CNRS, 38042 Grenoble (France); Lusakowski, J. [Institute of Experimental Physics, University of Warsaw, Hoza 69, 00-681 Warsaw (Poland); Krupczynski, W.; Bockowski, M. [TopGaN Ltd., Warsaw (Poland)

    2005-03-01

    We present transport properties of AlGaN/GaN heterostructures grown over high-pressure bulk GaN substrates. The experimental results include the conductivity tensor measurements in a magnetic field up to 23 T in a wide temperature range 2 K-300 K for Hall bar samples. The room temperature high field data allow us to clearly separate contributions of a parasitic parallel conduction from 2DEG conduction in all investigated heterostructures. The room temperature mobility limit for 2D electrons in GaN/AlGaN heterojunctions grown on defect free GaN bulk substrates is around 2400 cm{sup 2}/Vs. The Quantum Hall Effect studies are performed in the magnetic fields up to 23 T and temperatures between 1.6 K and 15 K This high magnetic field in combination with very high mobility (over 60000 cm{sup 2}/Vs) in the sample grown on the bulk GaN substrate allow us to determine the activation energy in cyclotron gap from longitudinal magnetoresistance. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  1. Numerical studies of liners for magnetized target fusion (MTF)

    CERN Document Server

    Faehl, R J; Sheehey, P T; Lindemuth, I R

    1999-01-01

    Summary form only given. Magnetized target fusion (MTF) requires the fast compression of hot, dense plasmas by a conducting liner. We have used two-dimensional MHD calculations to study the electromagnetic implosion of metallic liners driven by realistic current waveforms. Parametric studies have indicated that the liner should reach velocities of 3-20 km/s, depending on the magnetic field configuration, and reach convergence ratios (initial radius divided by final radius) of at least 10. These parameters are accessible with large capacitor bank power supplies such as SHIVA or ATLAS, or with magnetic flux compression generators. One issue with the high currents that are required to implode the liner is that Ohmic heating will melt or vaporize the outer part of the liner. Calculations have shown that this is a realistic concern. We are currently addressing questions of liner instability and flux diffusion under MTF conditions. Another issue is that the magnetic fields needed to inhibit thermal losses to the wa...

  2. Lanthanide Single-Molecule Magnets Framed by Alkali Metals & Magnetic and Spectroscopic Studies of 3d Transition Metal Complexes

    DEFF Research Database (Denmark)

    Konstantatos, Andreas

    This dissertation presents the results of our work on the synthesis and structural characterization of several families of coordination complexes as well as their study with regard to their magnetic properties. Chapter 1 provides a brief introduction in the field and theory of single-molecule...... and dynamic magnetic properties of these complexes is presented. A number of the reported complexes show single-molecule magnet behaviour in zero or non-zero applied static magnetic field. For these systems a study of their dynamics is presented and the mechanisms behind the relaxation are elucidated...... magnets (SMMs). Starting from the archetype SMM Mn12 we present the details of the mechanisms governing the relaxation of the magnetization of these systems. In Chapter 2 we present our work on the coordination chemistry of lanthanides with a new Schiff-base ligand, H3L [(E)-3-((2-hydroxyphenyl...

  3. Studying the mechanical responses of proteins using magnetic tweezers

    Science.gov (United States)

    Zhao, Xiaodan; Zeng, Xiangjun; Lu, Chen; Yan, Jie

    2017-10-01

    The mechanical stability of proteins has been extensively studied using AFM as a single-molecule force spectroscopy method. While this has led to many important results, these studies have been mainly limited to fast unfolding at a high-force regime due to the rapid mechanical drift in most AFM stretching experiments. Therefore, there is a gap between the knowledge obtained at a high-force regime and the mechanical properties of proteins at a lower force regime which is often more physiologically relevant. Recent studies have demonstrated that this gap can be addressed by stretching single protein molecules using magnetic tweezers, due to the excellent mechanical stability this technology offers. Here we review magnetic tweezers technology and its current application in studies of the force-dependent stability and interactions of proteins.

  4. Magnetic transition phase diagram of cobalt clusters electrodeposited on HOPG: Experimental and micromagnetic modelling study

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, M., E-mail: mrivera@fisica.unam.m [Imperial College London, Department of Chemistry, South Kensington Campus, London SW7 2AZ (United Kingdom); Rios-Reyes, C.H. [Universidad Autonoma Metropolitana-Azcapotzalco, Departamento de Materiales, Av. San Pablo 180, Col. Reynosa Tamaulipas, C.P. 02200, Mexico D.F. (Mexico); Universidad Autonoma del Estado de Hidalgo, Centro de Investigaciones Quimicas, Mineral de la Reforma, Hidalgo, C.P. 42181 (Mexico); Mendoza-Huizar, L.H. [Universidad Autonoma del Estado de Hidalgo, Centro de Investigaciones Quimicas, Mineral de la Reforma, Hidalgo, C.P. 42181 (Mexico)

    2011-04-15

    The magnetic transition from mono- to multidomain magnetic states of cobalt clusters electrodeposited on highly oriented pyrolytic graphite electrodes was studied experimentally using Magnetic Force Microscopy. From these images, it was found that the critical size of the magnetic transition is dominated by the height rather than the diameter of the aggregate. This experimental behavior was found to be consistent with a theoretical single-domain ferromagnetic model that states that a critical height limits the monodomain state. By analyzing the clusters magnetic states as a function of their dimensions, magnetic exchange constant and anisotropy value were obtained and used to calculate other magnetic properties such as the exchange length, magnetic wall thickness, etc. Finally, a micromagnetic simulation study correctly predicted the experimental magnetic transition phase diagram. - Research highlights: > Electrodeposition of cobalt clusters. > Mono to multidomain magnetic transition. > Magnetic phase diagram.

  5. Central magnetic cooling and refrigeration machines (chiller) and their assessment. A feasibility study - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Egolf, P. W.; Gonin, C. [University of Applied Sciences of Western Switzerland, HEIG-VD, Yverdon-les Bains (Switzerland); Kitanovski, A. [University of Ljubljana, Ljubljana (Slovenia)

    2010-03-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a feasibility study made concerning magnetic cooling and refrigeration machines. This report presents a comprehensive thermodynamic and economic analysis of applications of rotary magnetic chillers. The study deals with magnetic chillers based on permanent magnets and superconducting magnets, respectively. The numerical design of permanent magnet assemblies with different magnetic flux densities is discussed. The authors note that superconducting magnetic chillers are feasible only in large-scale applications with over 1 MW of cooling power. This report describes new ideas for magnetic refrigeration technologies, which go beyond the state of the art. They show potential for a substantial reduction of costs and further improvements in efficiency. Rotary magnetic liquid chillers with 'wavy' structures and using micro tubes are discussed, as are superconducting magnetic chillers and future magneto-caloric technologies.

  6. Study on control method of running velocity for the permanent magnet-HTSC hybrid magnetically levitated conveyance system

    Science.gov (United States)

    Nishio, R.; Ikeda, M.; Sasaki, R.; Ohashi, S.

    2011-11-01

    We have developed the magnetically levitated carrying system. In this system, pinning force of high temperature bulk super conductor (HTSC) is used for the levitation and guidance. Four HTSCs are installed on the carrier. The magnetic rail is set on the ground, and flux from the magnetic rail is pinned by HTSCs. To increase levitation force, repulsive force of the permanent magnet is used. The hybrid levitation system is composed. The permanent magnet is installed under the load stage of the carrier. Repulsive force by the permanent magnet between the load stage on the carrier and the magnetic rail on the ground is used to support the load weight. Levitation and guidance one by pinning effect of the YBaCuO HTSC in the carrier is used to levitate the carrier body. The load stage is separated from the carrier flame and can move freely for vertical direction levitation. For the propulsion system, electromagnet is installed on the surface of the magnetic rail. In this paper, control method of running velocity of the carrier is studied. Propulsion force is given as follows; Air core copper coils are installed on the magnetic rail. Interaction between current of these coils and permanent magnets on the carrier generates propulsion force. Running velocity is controlled by current of the propulsion coils. It is also changed by position of the carrier and the load weight. From the results, stability of the propulsion system is given, and propulsion characteristics are improved.

  7. Numerical evaluation of E-fields induced by body motion near high-field MRI scanner.

    Science.gov (United States)

    Crozier, S; Liu, F

    2004-01-01

    In modern magnetic resonance imaging (MRI), both patients and radiologists are exposed to strong, nonuniform static magnetic fields inside or outside of the scanner, in which the body movement may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced E-fields in the human model when moving at various positions around the magnet. The numerical calculations are based on an efficient, quasistatic, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively-shielded 4 T magnet system are used and the body model projected through the field profile with normalized velocity. The simulation shows that it is possible to induce E-fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are easy to extrapolate to very high field strengths for the safety evaluation at a variety of field strengths and motion velocities.

  8. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet and its sub-systems were stopped at the beginning of the winter shutdown on 8th December 2011. The magnet was left without cooling during the cryogenics maintenance until 17th January 2012, when the cryoplant operation resumed. The magnet temperature reached 93 K. The vacuum pumping was maintained during this period. During this shutdown, the yearly maintenance was performed on the cryogenics, the vacuum pumps, the magnet control and safety systems, and the power converter and discharge lines. Several preventive actions led to the replacement of the electrovalve command coils, and the 20A DC power supplies of the magnet control system. The filters were cleaned on the demineralised water circuits. The oil of the diffusion pumps was changed. On the cryogenics, warm nitrogen at 343 K was circulated in the cold box to regenerate the filters and the heat exchangers. The coalescing filters have been replaced at the inlet of both the turbines and the lubricant trapping unit. The active cha...

  9. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet was successfully operated at the end of the year 2009 despite some technical problems on the cryogenics. The magnet was ramped up to 3.8 T at the end of November until December 16th when the shutdown started. The magnet operation met a few unexpected stops. The field was reduced to 3.5 T for about 5 hours on December 3rd due to a faulty pressure sensor on the helium compressor. The following day the CERN CCC stopped unintentionally the power converters of the LHC and the experiments, triggering a ramp down that was stopped at 2.7 T. The magnet was back at 3.8 T about 6 hours after CCC sent the CERN-wide command. Three days later, a slow dump was triggered due to a stop of the pump feeding the power converter water-cooling circuit, during an intervention on the water-cooling plant done after several disturbances on the electrical distribution network. The magnet was back at 3.8 T in the evening the same day. On December 10th a break occurred in one turbine of the cold box producing the liquid ...

  10. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

      The magnet was operated without any problem until the end of the LHC run in February 2013, apart from a CERN-wide power glitch on 10 January 2013 that affected the CMS refrigerator, causing a ramp down to 2 T in order to reconnect the coldbox. Another CERN-wide power glitch on 15 January 2013 didn’t affect the magnet subsystems, the cryoplant or the power converter. At the end of the magnet run, the reconnection of the coldbox at 2.5 T was tested. The process will be updated, in particular the parameters of some PID valve controllers. The helium flow of the current leads was reduced but only for a few seconds. The exercise will be repeated with the revised parameters to validate the automatic reconnection process of the coldbox. During LS1, the water-cooling services will be reduced and many interventions are planned on the electrical services. Therefore, the magnet cryogenics and subsystems will be stopped for several months, and the magnet cannot be kept cold. In order to avoid unc...

  11. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The CMS magnet has been running steadily and smoothly since the summer, with no detected flaw. The magnet instrumentation is entirely operational and all the parameters are at their nominal values. Three power cuts on the electrical network affected the magnet run in the past five months, with no impact on the data-taking as the accelerator was also affected at the same time. On 22nd June, a thunderstorm caused a power glitch on the service electrical network. The primary water cooling at Point 5 was stopped. Despite a quick restart of the water cooling, the inlet temperature of the demineralised water on the busbar cooling circuit increased by 5 °C, up to 23.3 °C. It was kept below the threshold of 27 °C by switching off other cooling circuits to avoid the trigger of a slow dump of the magnet. The cold box of the cryogenics also stopped. Part of the spare liquid helium volume was used to maintain the cooling of the magnet at 4.5 K. The operators of the cryogenics quickly restarted ...

  12. Fundamental study of cesium decontamination from soil by superconducting magnet

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, Susumu, E-mail: igarashi@qb.see.eng.osaka-u.ac.jp; Mishima, Fumihito; Akiyama, Yoko, E-mail: yoko-ak@see.eng.osaka-u.ac.jp; Nishijima, Shigehiro

    2013-11-15

    Highlights: •The method for the soil decontamination by the superconducting magnet is proposed. •Cesium ion can be absorbed by Prussian blue in potassium iodide wash fluid. •It is possible to recover Cs{sup +} ion-adsorbing Prussian blue with a high rate by HGMS. •It is expected that HGMS can be applied to the actual soil decontamination. -- Abstract: The radioactive substances have been spread out all over the surrounding area of Fukushima Daiichi Nuclear Power Plant caused by the accident in March 2011. Decontamination and volume reduction of radioactive substances, especially cesium ion, are desired issue. This study proposed a decontamination method of the soil by the magnetic separation using superconducting magnet. Cesium ion was adsorbed by Prussian blue in the potassium iodide solution. We succeeded in separating selectively the cesium ion-adsorbed Prussian blue out of the liquid phase by high gradient magnetic separation. High recovery ratio of the Prussian blue was achieved by this method.

  13. Theoretical and experimental studies of a magnetically actuated valveless micropump

    Science.gov (United States)

    Ashouri, Majid; Behshad Shafii, Mohammad; Moosavi, Ali

    2017-01-01

    This paper presents the prototype design, fabrication, and characterization of a magnetically actuated micropump. The pump body consists of three nozzle/diffuser elements and two pumping chambers connected to the ends of a flat-wall pumping cylinder. A cylindrical permanent magnet placed inside the pumping cylinder acts as a piston which reciprocates by using an external magnetic actuator driven by a motor. The magnetic piston is covered by a ferrofluid to provide self-sealing capability. A prototype composed of three bonded layers of polymethyl-methacrylate (PMMA) has been fabricated. Water has been successfully pumped at pressures of up to 750 Pa and flow rates of up to 700 µl min-1 while working at the piston actuation frequency of 4 and 5 Hz, respectively. 3D numerical simulations are also carried out to study the performance of the pump. The best experimental and numerical volumetric efficiency of the pump are about 7 and 8%, respectively, at the piston speed of 0.03 m s-1. The contactless external actuation feature of the design enables integration of the pump with other PMMA-based microfluidic systems with low cost and disposability.

  14. Studies of SmCo5/Fe nanocomposite magnetic bilayers with magnetic soft x-ray transmission microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Shahzad, F.; Siddiqi, S. A.; Im, M.-Y.; Avallone, A.; Fischer, P.; Hussain, Z.; Siddiqi, I.; Hellman, F.; Zhao, J.

    2009-12-04

    A hard/soft SmCo{sub 5}/Fe nanocomposite magnetic bilayer system has been fabricated on X-ray transparent 100-200 nm thin Si{sub 3}N{sub 4} membranes by magnetron sputtering. The microscopic magnetic domain pattern and its behavior during magnetization reversal in the hard and soft magnetic phases have been individually studied by element specific magnetic soft x-ray microscopy at a spatial resolution of better than 25nm. We observe that the domain patterns for soft and hard phases switch coherently throughout the full hysteresis cycle upon applying external magnetic fields. We derived local M(H) curves from the images for Fe and SmCo5 separately and found switching for both hard and soft phases same.

  15. MAGNETS

    Science.gov (United States)

    Hofacker, H.B.

    1958-09-23

    This patent relates to nmgnets used in a calutron and more particularly to means fur clamping an assembly of magnet coils and coil spacers into tightly assembled relation in a fluid-tight vessel. The magnet comprises windings made up of an assembly of alternate pan-cake type coils and spacers disposed in a fluid-tight vessel. At one end of the tank a plurality of clamping strips are held firmly against the assembly by adjustable bolts extending through the adjacent wall. The foregoing arrangement permits taking up any looseness which may develop in the assembly of coils and spacers.

  16. Recent studies in satellite observations of three-dimensional magnetic reconnection

    Institute of Scientific and Technical Information of China (English)

    XIAO ChiJie; WANG XiaoGang; PU ZuYin; MA ZhiWei; ZHAO Hui; ZHOU GuiPing; WANG JingXiu; LIU ZhenXing

    2007-01-01

    Magnetic reconnection is a main process converting the magnetic energy into thermal and kinetic energy in plasmas. It is one of the fundamental problems of crucial importance not only to space plasmas physics and space weather studies,such as the solar flare, coronal mass ejections and magnetospheric substorms, but also to the stability analysis in magnetically confined fusion. In general, except for cases with periodical boundary conditions, three-dimensional (3D) magnetic reconnection occurs on magnetic separatrices generated by magnetic nulls. Here we briefly introduce/review the theories and some recent satellite observations of 3D magnetic reconnection. Topics to be further studied are also discussed.

  17. Neutron scattering studies on magnetic excitations in complex ordered manganites

    Energy Technology Data Exchange (ETDEWEB)

    Senff, D.

    2007-09-15

    This thesis deals with magnetic excitations in three different Manganese oxides, single-layered LaSrMnO{sub 4}, charge- and orbital-ordered La{sub 1/2}Sr{sub 3/2}MnO{sub 4}, and multiferroic TbMnO{sub 3}, which are studied by means of inelastic neutron scattering. The properties of the first system, LaSrMnO{sub 4}, are governed by the complex interplay of orbital, spin, and lattice degrees of freedom typical for the physics of manganites. The magnetic low-temperature behavior is quite unusual, and the comprehensive analysis of the spin-wave spectrum of LaSrMnO{sub 4} suggests a heterogenous ground state with ferromagnetic orbital polarons embedded in an antiferromagnetic background. The doped system La{sub 1/2}Sr{sub 3/2}MnO{sub 4} exhibits a stable charge- and orbital-ordered state, which today is discussed very controversially, as it is of great relevance for the colossal increase of electric conductivity at the metal-insulator transition in perovskite manganites. Analyzing the spin-wave dispersion of the ordered state, we find an excellent agreement with classical predictions by Goodenough and reject a recent alternative proposal. The different strength of the ferromagnetic and antiferromagnetic exchange in the CE-type ordering leads to the conclusion that the magnetic state has to be considered as a weak AFM coupling of stable FM elements. This thesis is further supported by the thermal evolution of the ordered state, revealing anisotropic correlations and the close competition of FM and AFM correlations above the Neel transition, as well as by the doping dependence of the charge- and orbital-ordered state, which is interpreted on the basis of a different response of the magnetic system with respect to additional electrons or holes. In the orthorhombic perovskite TbMnO{sub 3} the electric polarization is closely coupled to the magnetic degrees of freedom via a complex, non-collinear magnetic ordering. Precisely characterizing the different magnon excitations

  18. Case Studies on Superconducting Magnets for Particle Accelerators

    CERN Document Server

    Ferracin, P

    2014-01-01

    During the CERN Accelerator School 'Superconductivity for accelerators', the students were divided into 18 groups, and 6 different exercises (case studies), involving the design and analysis of superconducting magnets and RF cavities, were assigned. The problems covered a broad spectrum of topics, from properties of superconducting materials to operation conditions and general dimensions of components. The work carried out by the students turned out to be an extremely useful opportunity to review the material explained during the lectures, to become familiar with the orders of magnitude of the key parameters, and to understand and compare different design options. We provide in this paper a summary of the activities related to the case studies on superconducting magnets and present the main outcomes.

  19. Crystals for neutron scattering studies of quantum magnetism

    Energy Technology Data Exchange (ETDEWEB)

    Yankova, Tantiana [ETH Zurich, Switzerland; Hüvonen, Dan [ETH Zurich, Switzerland; Mühlbauer, Sebastian [ETH Zurich, Switzerland; Schmidiger, David [ETH Zurich, Switzerland; Wulf, Erik [ETH Zurich, Switzerland; Hong, Tao [ORNL; Garlea, Vasile O [ORNL; Custelcean, Radu [ORNL; Ehlers, Georg [ORNL

    2012-01-01

    We review a strategy for targeted synthesis of large single crystal samples of prototype quantum magnets for inelastic neutron scattering experiments. Four case studies of organic copper halogenide S = 1/2 systems are presented. They are meant to illustrate that exciting experimental results pertaining to the forefront of many-body quantum physics can be obtained on samples grown using very simple techniques, standard laboratory equipment, and almost no experience in advanced crystal growth techniques.

  20. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  1. Magnetic single-domain state of the monochiral helimagnet MnSi in the zero-field limit: Magnetic properties study

    Science.gov (United States)

    Narozhnyi, V. N.; Krasnorussky, V. N.

    2015-04-01

    Attention is drawn to the possibility of obtaining the monochiral helimagnet MnSi in the magnetic single-domain state (SDS) in a zero magnetic field limit. It is shown that this metastable zero-field magnetic SDS can be achieved by a gradual decrease of the field down to zero after an initial transformation of MnSi to a spin-polarized state in a high field H . This can be achieved only for H ∥[111 ] . Investigations of MnSi in the magnetic SDS give us the possibility of determining the two components of the low field magnetic susceptibility of this compound, χ⊥(T ) and χ∥(T ) [χ⊥ and χ∥ correspond to H ⊥(111 ) and H ∥(111 ) planes containing magnetic moments in a helically ordered state]. These results are compared with the macroscopic magnetic susceptibility of MnSi that was determined earlier for this compound, but only in a magnetic multidomain state. In addition, our results are compared with the data reported for some nonmonochiral helimagnets. The characteristic features of monochiral helimagnets are elucidated.

  2. Synchrotron Applications of High Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This workshop aims at discussing the scientific potential of X-ray diffraction and spectroscopy in magnetic fields above 30 T. Pulsed magnetic fields in the range of 30 to 40 T have recently become available at Spring-8 and the ESRF (European synchrotron radiation facility). This document gathers the transparencies of the 6 following presentations: 1) pulsed magnetic fields at ESRF: first results; 2) X-ray spectroscopy and diffraction experiments by using mini-coils: applications to valence state transition and frustrated magnet; 3) R{sub 5}(Si{sub x}Ge{sub 1-x}){sub 4}: an ideal system to be studied in X-ray under high magnetic field?; 4) high field studies at the Advanced Photon Source: present status and future plans; 5) synchrotron X-ray diffraction studies under extreme conditions; and 6) projects for pulsed and steady high magnetic fields at the ESRF.

  3. ELF electric and magnetic fields: Pacific Northwest Laboratory studies

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, L.E.

    1992-06-01

    Studies have been conducted at Battelle, Pacific Northwest Laboratory, to examine extremely-low-frequency (ELF) electromagnetic fields for possible biological effects in animals. Three areas of investigation are reported here: (1) studies on the nervous system, including behavior and neuroendocrine function, (2) experiments on cancer development in animals, and (3) measurements of currents and electric fields induced in animal models by exposure to external magnetic fields. In behavioral experiments, rats have been shown to be responsive to ELF electric field exposure. Furthermore, experimental data indicate that short-term memory may be affected in albino rats exposed to combined ELF and static magnetic fields. Neuroendocrine studies have been conducted to demonstrate an apparent stress-related response in rats exposed to 60-Hz electric fields. Nighttime pineal melatonin levels have been shown to be significantly depressed in animals exposed to either electric or magnetic fields. A number of animal tumor models are currently under investigation to examine possible relationships between ELF exposure and carcinogenesis. Finally, theoretical and experimental measurements have been performed which form the basis for animals and human exposure comparisons.

  4. Experimental Study on Current Decay Characteristics of Persistent Current HTS Magnet by Alternating Magnetic Field

    Science.gov (United States)

    Park, Young Gun; Lee, Chang Young; Hwang, Young Jin; Lee, Woo Seung; Lee, Jiho; Jo, Hyun Chul; Chung, Yoon Do; Ko, Tae Kuk

    This paper deals with a current decay characteristics of a high temperature superconducting (HTS) magnet operated in persistent current mode (PCM). In superconducting synchronous machine applications such as linear synchronous motor (LSM), the superconducting coil is designed to operate in the PCM to obtain steady magnetic field with DC transport current. This superconducting magnet operates on a direct current, but it can be exposed to alternating magnetic field due to the armature winding. When the magnet is subjected to an external time-varying magnetic field, it is possible to result in a decay of the current in PCM system due to AC loss. In this research, a PCM system with armature coil which generates time-varying magnetic field was fabricated to verify current decay characteristics by external alternating magnetic field. The current decay rate was measured by using a hall sensor as functions of amplitude and frequency of armature coil.

  5. Toward 20 T magnetic resonance for human brain studies: opportunities for discovery and neuroscience rationale.

    Science.gov (United States)

    Budinger, Thomas F; Bird, Mark D; Frydman, Lucio; Long, Joanna R; Mareci, Thomas H; Rooney, William D; Rosen, Bruce; Schenck, John F; Schepkin, Victor D; Sherry, A Dean; Sodickson, Daniel K; Springer, Charles S; Thulborn, Keith R; Uğurbil, Kamil; Wald, Lawrence L

    2016-06-01

    An initiative to design and build magnetic resonance imaging (MRI) and spectroscopy (MRS) instruments at 14 T and beyond to 20 T has been underway since 2012. This initiative has been supported by 22 interested participants from the USA and Europe, of which 15 are authors of this review. Advances in high temperature superconductor materials, advances in cryocooling engineering, prospects for non-persistent mode stable magnets, and experiences gained from large-bore, high-field magnet engineering for the nuclear fusion endeavors support the feasibility of a human brain MRI and MRS system with 1 ppm homogeneity over at least a 16-cm diameter volume and a bore size of 68 cm. Twelve neuroscience opportunities are presented as well as an analysis of the biophysical and physiological effects to be investigated before exposing human subjects to the high fields of 14 T and beyond.

  6. Magnetic relaxations in a Tb-based single molecule magnet studied by quasielastic neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kofu, Maiko [Institute for Solid State Physics, University of Tokyo, Kashiwa, Chiba 277-8581 (Japan); Kajiwara, Takashi [Faculty of Science, Nara Women’s University, Nara, Nara 630-8506 (Japan); Gardner, Jason S. [NIST Center for Neutron Research, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899-6102 (United States); Simeoni, Giovanna G. [Technische Universität München, Forschungsneutronenquelle Heinz Maier-Leibnitz FRM II, D-85747 Garching (Germany); Tyagi, Madhusudan; Faraone, Antonio [NIST Center for Neutron Research, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899-6102 (United States); Department of Materials Science, University of Maryland, College Park, MD 20742 (United States); Nakajima, Kenji; Ohira-Kawamura, Seiko [Neutron Science Section, J-PARC Center, Tokai, Ibaraki 319-1195 (Japan); Nakano, Motohiro [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); Yamamuro, Osamu, E-mail: yamamuro@issp.u-tokyo.ac.jp [Institute for Solid State Physics, University of Tokyo, Kashiwa, Chiba 277-8581 (Japan)

    2013-12-12

    Highlights: • We examined a Tb based single molecule magnet by ac susceptibility and QENS. • We found two distinct magnetic relaxations in a wide time range from 0.1 ms to 1 ps. • The slower relaxation corresponds to the thermally activated tunneling process. • The faster one couples with the motion of H atoms around the magnetic ions. • The two relaxations exhibit a crossover around 100 ns. - Abstract: By using ac magnetic susceptibility and quasielatic neutron scattering (QENS) techniques, we have investigated a magnetization relaxation phenomenon of a rare-earth based single molecule magnet, TbCuC{sub 19}H{sub 20}N{sub 3}O{sub 16}. We clearly identified and characterized two magnetic relaxations. The slower relaxation observed in the ac susceptibility is at the ms timescale around T=2 K and its activation energy is 16 K. On the other hand, the faster relaxation in the QENS measurements occurs on the timescale between ns and ps with activation energy of 174 K. The slower relaxation may occur through thermally activated tunneling among magnetic substates. We discuss two possible origins for the faster relaxation; one is a thermally activated tunneling between the higher excited states, the other is the magnetic relaxation coupled with the motion of ligands around the magnetic ions. This is the first clear observation of magnetic relaxation on the single molecule magnet revealed by QENS.

  7. Rotational dynamics of magnetic silica spheres studied by measuring the complex magnetic susceptibility

    NARCIS (Netherlands)

    Claesson, E.M.; Erne, B.H.; Philipse, A.P.

    2007-01-01

    The weak permanent magnetic dipole moment of cobalt ferrite-doped colloidal silica spheres was increased by exposure to a saturating magnetic field. The resulting change of the rotational dynamics of the magnetic microspheres in a weak alternating field was measured from low to high volume fraction

  8. Intraoperative high field magnetic resonance imaging combined with pyramidal tract navigation for resection of thalamic gliomas%术中高场强磁共振联合锥体束导航在丘脑胶质瘤切除手术中的应用

    Institute of Scientific and Technical Information of China (English)

    吴东东; 陈晓雷; 耿杰峰; 张猛; 白少聪; 王群; 马晓东; 许百男

    2015-01-01

    Objective To explore the clinical value of high field iMRI combined with pyramidal tract navigation on the resection of thalamic gliomas. Methods Clinical data about 28 patients with thalamic gliomas admitted to our hospital from March 2009 to April 2014 were retrospectively analyzed. All patients underwent microsurgery aided by iMRI combined pyramidal tract navigation. The extent of resection (EOR) of tumors, pre- and post-operative Karnofsky performance scale (KPS) and myodynamia were evaluated. Results iMRI scanning revealed residual tumors in 22 of 28 patients, and 15 patients received further resection which increased EOR. Three weeks after surgery, neurological functions improved or kept no change in 22 cases, and 6 cases experienced neurological function decline, however, the KPS score of these 6 patients were higher than 60, which suggested that the patients could take care of themselves. Conclusion iMRI combined with pyramidal tract navigation is helpful to maximize the resection of thalamic gliomas and decrease incidence of the neurologic deficits.%目的:探讨术中高场强磁共振联合锥体束导航在丘脑胶质瘤切除手术中的应用价值。方法回顾性研究2009年3月-2014年4月本院神经外科收治的28例接受1.5 T高场强术中磁共振联合锥体束导航辅助显微切除手术的丘脑胶质瘤患者临床资料,分析评估了所有患者的肿瘤切除程度、术前术后行为状态评分(Karnofsky performance scale,KPS)和肌力。结果28例患者中有22例术中扫描后发现肿瘤残留,其中15例患者的残留肿瘤得以进一步切除,提高了肿瘤切除程度。术后3周,22例神经功能改善或同术前,6例神经功能下降,但是功能下降者KPS均>60,即生活均可自理。结论术中高场强磁共振联合锥体束导航有助于提高丘脑胶质瘤切除程度,减少术后运动功能障碍的发生率。

  9. Study of local structure and magnetism in high-T(sub c) copper oxide superconductors

    Science.gov (United States)

    Budnick, J. I.; Tan, Z.; Filipkowski, M.; Niedermayer, CH.; Glueckler, H.; Simon, R.; Golnik, A.; Rauer, M.; Recknagel, E.; Weidinger, A.

    1990-01-01

    The muon spin rotation (MUSR) study of local magnetism of Sr-doped La2CuO4 is reviewed. Emphasis is placed on magnetic order as detected by local and bulk probes with local atomic environments studied by x ray absorption fine structure (XAFS). Correlations between the MUSR study of local magnetic ordering and the bulk magnetization study are presented along with a discussion of the dependence upon oxygen stoichiometry. Results are presented for both superconducting phases and magnetic phases. Recent data which reveals the existence of local magnetic ordering in the hydrogen-doped YBa2Cu3O7 system are also discussed.

  10. Experimental Study on Characteristics of NiMnGa Magnetically Controlled Shape Memory Alloy

    Institute of Scientific and Technical Information of China (English)

    Fengxiang WANG; Wenjun LI; Qingxin ZHANG; Chenxi LI; Xinjie WU

    2006-01-01

    The static and dynamic magnetic controlling characteristics of NiMnGa magnetically controlled shape memory alloy (MSMA) were experimentally studied. The results show that the characteristics of induced strain with respect to the magnetic field are nonlinear with saturation nature, and dependent on the temperature as well as the load applied to the MSMA. The magnetic shape memory effect can be observed only in complete martensite phase at room temperature. The magnetic permeability of MSMA is not constant and reduces with the increment of magnetic field. The relative saturation magnetic permeability of MSMA is about 1.5.

  11. A magnetic Compton scattering study of NpNiGa{sub 5}

    Energy Technology Data Exchange (ETDEWEB)

    Tsutsui, S. [Japan Synchrotron Radiation Research Institute, SPring-8, Mikazuki, Hyogo 679-5198 (Japan)]. E-mail: satoshi@spring8.or.jp; Sakurai, Y. [Japan Synchrotron Radiation Research Institute, SPring-8, Mikazuki, Hyogo 679-5198 (Japan); Itou, M. [Japan Synchrotron Radiation Research Institute, SPring-8, Mikazuki, Hyogo 679-5198 (Japan); Aoki, D. [Institute for Materials Science, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Yamamoto, E. [Advanced Science Research Center, Japan Atomic Energy Research Institute, Tokai, Ibaraki 319-1195 (Japan); Homma, Y. [Institute for Materials Science, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Haga, Y. [Advanced Science Research Center, Japan Atomic Energy Research Institute, Tokai, Ibaraki 319-1195 (Japan); Nakamura, A. [Advanced Science Research Center, Japan Atomic Energy Research Institute, Tokai, Ibaraki 319-1195 (Japan); Shiokawa, Y. [Institute for Materials Science, Tohoku University, Oarai, Ibaraki 311-1313 (Japan); Onuki, Y. [Graduate School of Science, Osaka University, Toyonaka, Osaka 560-0043 (Japan)

    2006-05-01

    We have performed the first magnetic Compton scattering study of a transuranium compound, NpNiGa{sub 5}. We have measured magnetic Compton profiles in two magnetic ordered phases of this compound. The magnetic Compton profiles in both ordered phases indicate that ferromagnetic components exist in the ordered phases. The signs of the magnetic effects suggest that the contribution of the 5f electrons of Np atoms is dominant to the total spin moments in the ordered phases.

  12. A study of two-dimensional magnetic polaron

    Institute of Scientific and Technical Information of China (English)

    LIU; Tao; ZHANG; Huaihong; FENG; Mang; WANG; Kelin

    2006-01-01

    By using the variational method and anneal simulation, we study in this paper the self-trapped magnetic polaron (STMP) in two-dimensional anti-ferromagnetic material and the bound magnetic polaron (BMP) in ferromagnetic material. Schwinger angular momentum theory is applied to changing the problem into a coupling problem of carriers and two types of Bosons. Our calculation shows that there are single-peak and multi-peak structures in the two-dimensional STMP. For the ferromagnetic material, the properties of the two-dimensional BMP are almost the same as that in one-dimensional case; but for the anti-ferromagnetic material, the two-dimensional STMP structure is much richer than the one-dimensional case.

  13. Familial Essential Tremor Studied With Functional Magnetic Resonance Imaging

    Science.gov (United States)

    Hernandez, A.; Salgado, P.; Gil, A.; Barrios, F. A.

    2003-09-01

    Functional Magnetic Resonance Imaging has become an important analytical tool to study neurodegenerative diseases. We applied the EPI-BOLD functional Magnetic Resonance Imaging technique to acquire functional images of patients with familial essential tremor (FET) disorder and healthy control volunteers, during a motor task activity. Functional and anatomic images were used to produce the brain activation maps of the patients and volunteers. These functional maps of the primary somatosensorial and motor cortexes of patients and control subjects were compared for functional differences per subject. The averaged functional brain images of eight of each case were acquired were, it can be clearly observed the differences in active zones. The results presented in this work show that there are differences in the functional maps during motor task activation between control subjects and FET patients suggesting a cerebral functional reorganization that can be mapped with BOLD-fMRI.

  14. A Comparative Study of Novel Topologies of Magnetic Gears

    Directory of Open Access Journals (Sweden)

    Shuangxia Niu

    2016-09-01

    Full Text Available The magnetic gear (MG is an emerging technology that has been proved to possess superior performance over the conventional mechanical gear in many aspects. However, the existing markets of traditional mechanical gears have not yet been replaced by MGs. One of the major reasons is that MGs are susceptible to the permanent magnet (PM materials, which are scarce and expensive, while mechanical counterparts are impervious to that. To solve such issues, the comparative studies of various designs of triple-layer PM-excited MGs are carried out to find out the optimal torque per unit PM volume design. The methodology of the Tabu algorithm is coupled with the finite element method (FEM to search out the optimal solution of MGs.

  15. Study on control method of running velocity for the permanent magnet-HTSC hybrid magnetically levitated conveyance system

    Energy Technology Data Exchange (ETDEWEB)

    Nishio, R.; Ikeda, M.; Sasaki, R. [Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan); Ohashi, S., E-mail: ohashi@kansai-u.ac.jp [Kansai University, 3-3-35 Yamate-cho, Suita, Osaka 564-8680 (Japan)

    2011-11-15

    The hybrid magnetically levitated carrying system is developed. Control method of running velocity of the carrier is studied. Running velocity is controlled by current of the propulsion coils. Propulsion characteristcs are improved. We have developed the magnetically levitated carrying system. In this system, pinning force of high temperature bulk super conductor (HTSC) is used for the levitation and guidance. Four HTSCs are installed on the carrier. The magnetic rail is set on the ground, and flux from the magnetic rail is pinned by HTSCs. To increase levitation force, repulsive force of the permanent magnet is used. The hybrid levitation system is composed. The permanent magnet is installed under the load stage of the carrier. Repulsive force by the permanent magnet between the load stage on the carrier and the magnetic rail on the ground is used to support the load weight. Levitation and guidance one by pinning effect of the YBaCuO HTSC in the carrier is used to levitate the carrier body. The load stage is separated from the carrier flame and can move freely for vertical direction levitation. For the propulsion system, electromagnet is installed on the surface of the magnetic rail. In this paper, control method of running velocity of the carrier is studied. Propulsion force is given as follows; Air core copper coils are installed on the magnetic rail. Interaction between current of these coils and permanent magnets on the carrier generates propulsion force. Running velocity is controlled by current of the propulsion coils. It is also changed by position of the carrier and the load weight. From the results, stability of the propulsion system is given, and propulsion characteristics are improved.

  16. Experimental Studies with an Active Magnetic Regenerating Refrigerator

    DEFF Research Database (Denmark)

    Eriksen, Dan; Engelbrecht, Kurt; Bahl, Christian

    2015-01-01

    Experimental results for an active magnetic regenerator (AMR) are presented. The focus is on whether or not it pays off to partly substitute soft magnetic material with non-magnetic insulation in a flux-conducting core in the magnet system. Such a substitution reduces losses due to heat conductio...

  17. Transport Studies of Quantum Magnetism: Physics and Methods

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Minhyea [Univ. of Colorado, Boulder, CO (United States)

    2017-03-30

    The main goal of this project was to understand novel ground states of spin systems probed by thermal and electrical transport measurements. They are well-suited to characterize the nature of low-energy excitations as unique property of the ground state. More specifically, it was aimed to study the transverse electrical conductivity in the presence of non-collinear and non-coplanar spin ordering and the effects of gauge field as well as novel spin excitations as a coherent heat transport channel in insulating quantum magnets. Most of works done during the grant period focused on these topics. As a natural extension of the project's initial goals, the scope was broadened to include transport studies on the spin systems with strong spin-orbit coupling. One particular focus was an exploration of systems with strong magnetic anisotropy combined with non-trivial spin configuration. Magnetic anisotropy is directly related to implement the non-collinear spin ordering to the existing common geometry of planar devices and thus poses a significant potential. Work in this direction includes the comparison of the topological Hall signal under hydrostatic pressure and chemical doping, as well as the angular dependence dependence of the non-collinear spin ordered phase and their evolution up on temperature and field strength. Another focus was centered around the experimental identification of spin-originated heat carrying excitation in quasi two dimensional honeycomb lattice, where Kitaev type of quantum spin liquid phase is expected to emerge. In fact, when its long range magnetic order is destroyed by the applied field, we discovered anomalously large enhancement of thermal conductivity, for which proximate Kitaev excitations in field-induced spin liquid state are responsible for. This work, combined with further investigations in materials in the similar class may help establish the experimental characterization of new quantum spin liquid and their unique low energy

  18. Infrared thermography based magnetic hyperthermia study in Fe3O4 based magnetic fluids

    Science.gov (United States)

    Lahiri, B. B.; Ranoo, Surojit; Philip, John

    2016-09-01

    Owing to the immense clinical benefits, magnetic hyperthermia is likely to emerge as an alternate cancer therapeutic procedure in the near future. Presently, radio frequency immune fiber optic based sensors are being used to monitor temperature changes during magnetic hyperthermia measurements, which have inherent limitations due to the requirement of physical contact of the sensor with the sample, contamination and temperature monitoring at a single point. Here, we investigate the field induced heating of oil based oleic acid coated Fe3O4 nanofluid, synthesized using co-precipitation method, using infrared thermal imaging (IRT) camera and compare the results with those of fiber optic temperature sensor. Experiments were performed on nanofluid samples of four different concentrations and under five different external field amplitudes. The specific absorption rate (SAR) of the samples were determined from the initial rate of temperature rise measured using both the techniques. The SAR values determined from both the techniques were in very good agreement with each other, with in an accuracy of 5%, after incorporating convection loss correction on the infrared thermal imaging data. The consecutive thermal cycling on the samples showed good thermal stability and thermal recovery. The maximum SAR obtained was 95.9 W/gFe for a sample concentration and field amplitude of 23 wt.% and 57.3 kA m-1, respectively. This study showed the efficacy and accuracy of temperature measurement using IRT during field induced heating of magnetic nanofluid and its advantages over conventional point measurements techniques for real-time, non-contact and wide area temperature mapping without sample contamination.

  19. Ideal charge-density-wave order in the high-field state of superconducting YBCO

    Science.gov (United States)

    Jang, H.; Lee, W.-S.; Nojiri, H.; Matsuzawa, S.; Yasumura, H.; Nie, L.; Maharaj, A. V.; Gerber, S.; Liu, Y.-J.; Mehta, A.; Bonn, D. A.; Liang, R.; Hardy, W. N.; Burns, C. A.; Islam, Z.; Song, S.; Hastings, J.; Devereaux, T. P.; Shen, Z.-X.; Kivelson, S. A.; Kao, C.-C.; Zhu, D.; Lee, J.-S.

    2016-12-01

    The existence of charge-density-wave (CDW) correlations in cuprate superconductors has now been established. However, the nature of the CDW ground state has remained uncertain because disorder and the presence of superconductivity typically limit the CDW correlation lengths to only a dozen unit cells or less. Here we explore the field-induced 3D CDW correlations in extremely pure detwinned crystals of YBa2Cu3O2 (YBCO) ortho-II and ortho-VIII at magnetic fields in excess of the resistive upper critical field (Hc2Hc2) where superconductivity is heavily suppressed. We observe that the 3D CDW is unidirectional and possesses a long in-plane correlation length as well as significant correlations between neighboring CuO2 planes. It is significant that we observe only a single sharply defined transition at a critical field proportional to Hc2Hc2, given that the field range used in this investigation overlaps with other high-field experiments including quantum oscillation measurements. The correlation volume is at least two to three orders of magnitude larger than that of the zero-field CDW. This is by far the largest CDW correlation volume observed in any cuprate crystal and so is presumably representative of the high-field ground state of an “ideal” disorder-free cuprate.

  20. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

    The magnet is fully stopped and at room temperature. The maintenance works and consolidation activities on the magnet sub-systems are progressing. To consolidate the cryogenic installation, two redundant helium compressors will be installed as ‘hot spares’, to avoid the risk of a magnet downtime in case of a major failure of a compressor unit during operation. The screw compressors, their motors, the mechanical couplings and the concrete blocks are already available and stored at P5. The metallic structure used to access the existing compressors in SH5 will be modified to allow the installation of the two redundant ones. The plan is to finish the installation and commissioning of the hot spare compressors before the summer 2014. In the meantime, a bypass on the high-pressure helium piping will be installed for the connection of a helium drier unit later during the Long Shutdown 1, keeping this installation out of the schedule critical path. A proposal is now being prepared for the con...