WorldWideScience

Sample records for high-dose wa-implanted rats

  1. Nonlinear model of high-dose implantation

    International Nuclear Information System (INIS)

    Danilyuk, A.

    2001-01-01

    The models of high-dose implantation, using the distribution functions, are relatively simple. However, they must take into account the variation of the function of distribution of the implanted ions with increasing dose [1-4]. This variation takes place owing to the fact that the increase of the concentration of the implanted ions results in a change of the properties of the target. High-dose implantation is accompanied by sputtering, volume growth, diffusion, generation of defects, formation of new phases, etc. The variation of the distribution function is determined by many factors and is not known in advance. The variation within the framework of these models [1-4] is taken into account in advance by the introduction of intuitive assumptions on the basis of implicit considerations. Therefore, these attempts should be regarded as incorrect. The model prepared here makes it possible to take into account the sputtering of the target, volume growth and additional declaration on the implanted ions. Without any assumptions in relation to the variation of the distribution function with increasing dose. In our model it is assumed that the type of distribution function for small doses in a pure target substance is the same as in substances with implanted ions. A second assumption relates to the type of the distribution function valid for small doses in the given substances. These functions are determined as a result of a large number of theoretical and experimental investigations and are well-known at the present time. They include the symmetric and nonsymmetric Gauss distribution, the Pearson distribution, and others. We examine implantation with small doses of up to 10 14 - 10 15 cm -2 when the accurately known distribution is valid

  2. [Effect of low dose aspirin on osseointegration around titanium implants in osteoporotic rats].

    Science.gov (United States)

    Yang, Q; Li, F L

    2018-02-09

    Objective: To investigate the effect of aspirin on osseointegration around titanium implants in ostoeporotic rats and to provide evidence for future researches and clinical application. Methods: A total of 60 female SD rats, aged 3-4 months, were divided into ovariectomy group (Ovx group, n= 48) and sham-ovariectomy group (Sham group, n= 12). The rats in Ovx group received ovariectomy and those in Sham group underwent sham-ovariectomy. Twelve weeks later, six rats in each group were randomly selected to confirm the osteoporosis models. The Ovx group was divided into 4 subgroups with 12 rats in each group, namely the osteoporosis group (OP group), and Aspirin groups (A1, A2, A3 group). Pure screw titanium implants were placed in the right tibia near metaphysis of all rats. Three days after implant surgery, aspirin groups were intragastrically administered aspirin at a dose of 2.06, 4.11, 8.21 mg·kg(-1)·d(-1) (A1, A2, A3), and OP group and Sham group were fed the same amount of normal saline. Four and 12 weeks following implantations surgery, half of the rats in each group were randomly chosen and sacrificed. Implant bone contact rate (IBCR), combined bone lamella width (CBLW) and trabercular width (TW) were observed and calculated using histomorphometric measurement. Results: Four weeks after implantations surgery, the TW and CBLW of rats in A1 group [(39.60±2.77) and (27.56±4.14) μm] and the IBCR, TW and CBLW of rats in A2 group and A3 group [A2: (47.21±4.19)%, (48.74±3.20) and (35.91±3.79) μm; A3: (47.35±6.07)%, (50.27±5.25) and (40.66±2.11) μm] were much higher than those in OP group [(33.89±7.17)%, (32.20±6.10) and (19.77±6.80) μm]( P 0.05). Twelve weeks after implantations surgery, the IBCR and CBLW of rats in A1 group [ (85.86±3.64) %, (53.12±8.68) μm], and the IBCR, TW and CBLW of rats in A2 group and A3 group [A2: (85.64±3.97)%, (69.42±6.78) and (54.19±3.12) μm; A3: (86.22±3.48)%, (75.43±3.50) and (55.79±5.60) μm] were much higher

  3. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  4. Does gestrinone antagonize the effects of estrogen on endometrial implants upon the peritoneum of rats?

    Directory of Open Access Journals (Sweden)

    Vera Lúcia Rodrigues Lobo

    2008-01-01

    Full Text Available OBJECTIVE: To evaluate the effects of estrogen treatment in combination with gestrinone on an experimental rat model of endometriosis. METHODS: Uterine transplants were attached to the peritoneum of female Wistar rats via a surgical autotransplantation technique. The implanted area was measured during the proestrus phase and after hormonal treatment. We performed morphometric analysis and examined the macroscopic and morphometric alterations of endometrial implants after hormonal treatment in ovariectomized rats. RESULTS: The high dose of estrogen caused macroscopic increases in the endometrial implant group compared with other groups, which were similar to increases in the proestrus phase. The low dose showed morphometric development of implants, such as an increase in number of endometrial glands, leukocyte infiltration and mitosis. Gestrinone antagonized both doses of estrogen. CONCLUSION: Our findings suggest that gestrinone antagonizes estrogen's effects on rat peritoneal endometrial implants.

  5. Carcinogenicity and Immunotoxicity of Embedded Depleted Uranium and Heavy-Metal Tugsten Alloy in Rodents

    National Research Council Canada - National Science Library

    Kalinich, John

    2004-01-01

    .... In addition, rats in the high-dose WA group exhibited signs of polycythemia as early as one month after pellet implantation. Rats in the DU or tantalum groups showed no pellet-associated tumors for up to 2 years after implantation.

  6. Pure high dose metal ion implantation using the plasma immersion technique

    International Nuclear Information System (INIS)

    Zhang, T.; Tang, B.Y.; Zeng, Z.M.; Kwok, T.K.; Chu, P.K.; Monteiro, O.R.; Brown, I.G.

    1999-01-01

    High energy implantation of metal ions can be carried out using conventional ion implantation with a mass-selected ion beam in scanned-spot mode by employing a broad-beam approach such as with a vacuum arc ion source, or by utilizing plasma immersion ion implantation with a metal plasma. For many high dose applications, the use of plasma immersion techniques offers a high-rate process, but the formation of a surface film along with the subsurface implanted layer is sometimes a severe or even fatal detriment. We describe here an operating mode of the metal plasma immersion approach by which pure implantation can be obtained. We have demonstrated the technique by carrying out Ti and Ta implantations at energies of about 80 and 120 keV for Ti and Ta, respectively, and doses on the order of 1x10 17 ions/cm 2 . Our experiments show that virtually pure implantation without simultaneous surface deposition can be accomplished. Using proper synchronization of the metal arc and sample voltage pulse, the applied dose that deposits as a film versus the part that is energetically implanted (the deposition-to-implantation ratio) can be precisely controlled.copyright 1999 American Institute of Physics

  7. High-dose MeV electron irradiation of Si-SiO2 structures implanted with high doses Si+

    Science.gov (United States)

    Kaschieva, S.; Angelov, Ch; Dmitriev, S. N.

    2018-03-01

    The influence was studied of 22-MeV electron irradiation on Si-SiO2 structures implanted with high-fluence Si+ ions. Our earlier works demonstrated that Si redistribution is observed in Si+-ion-implanted Si-SiO2 structures (after MeV electron irradiation) only in the case when ion implantation is carried out with a higher fluence (1016 cm-2). We focused our attention on the interaction of high-dose MeV electron irradiation (6.0×1016 cm-2) with n-Si-SiO2 structures implanted with Si+ ions (fluence 5.4×1016 cm-2 of the same order magnitude). The redistribution of both oxygen and silicon atoms in the implanted Si-SiO2 samples after MeV electron irradiation was studied by Rutherford back-scattering (RBS) spectroscopy in combination with a channeling technique (RBS/C). Our results demonstrated that the redistribution of oxygen and silicon atoms in the implanted samples reaches saturation after these high doses of MeV electron irradiation. The transformation of amorphous SiO2 surface into crystalline Si nanostructures (after MeV electron irradiation) was evidenced by atomic force microscopy (AFM). Silicon nanocrystals are formed on the SiO2 surface after MeV electron irradiation. The shape and number of the Si nanocrystals on the SiO2 surface depend on the MeV electron irradiation, while their size increases with the dose. The mean Si nanocrystals height is 16-20 nm after irradiation with MeV electrons at the dose of 6.0×1016 cm-2.

  8. High dose rate (HDR) and low dose rate (LDR) interstitial irradiation (IRT) of the rat spinal cord

    International Nuclear Information System (INIS)

    Pop, Lucas A.M.; Plas, Mirjam van der; Skwarchuk, Mark W.; Hanssen, Alex E.J.; Kogel, Albert J. van der

    1997-01-01

    Purpose: To describe a newly developed technique to study radiation tolerance of rat spinal cord to continuous interstitial irradiation (IRT) at different dose rates. Material and methods: Two parallel catheters are inserted just laterally on each side of the vertebral bodies from the level of Th 10 to L 4 . These catheters are afterloaded with two 192 Ir wires of 4 cm length each (activity 1-2.3 mCi/cm) for the low dose rate (LDR) IRT or connected to the HDR micro-Selectron for the high dose rate (HDR) IRT. Spinal cord target volume is located at the level of Th 12 -L 2 . Due to the rapid dose fall-off around the implanted sources, a dose inhomogeneity across the spinal cord thickness is obtained in the dorso-ventral direction. Using the 100% reference dose (rate) at the ventral side of the spinal cord to prescribe the dose, experiments have been carried out to obtain complete dose response curves at average dose rates of 0.49, 0.96 and 120 Gy/h. Paralysis of the hind-legs after 5-6 months and histopathological examination of the spinal cord of each irradiated rat are used as experimental endpoints. Results: The histopathological damage seen after irradiation is clearly reflected the inhomogeneous dose distribution around the implanted catheters, with the damage predominantly located in the dorsal tract of the cord or dorsal roots. With each reduction in average dose rate, spinal cord radiation tolerance is significantly increased. When the dose is prescribed at the 100% reference dose rate, the ED 50 (induction of paresis in 50% of the animals) for the HDR-IRT is 17.3 Gy. If the average dose rate is reduced from 120 Gy/h to 0.96 or 0.49 Gy/h, a 2.9- or 4.7-fold increase in the ED 50 values to 50.3 Gy and 80.9 Gy is observed; for the dose prescribed at the 150% reference dose rate (dorsal side of cord) ED 50 values are 26.0, 75.5 and 121.4 Gy, respectively. Using different types of analysis and in dependence of the dose prescription and reference dose rate, the

  9. In vivo dosimetry of high-dose fractionated irradiation in an experimental set-up with rats

    Energy Technology Data Exchange (ETDEWEB)

    Fortan, L; Van Hecke, H; Van Duyse, B; De Neve, W; De Meerleer, B [Ghent Rijksuniversiteit (Belgium). Kliniek voor Radiotherapie en Kerngeneeskunde; Pattyn, P; Van Renthergem, K [Ghent University (Belgium). Dept. of Surgery

    1995-12-01

    The feasibility to irradiate a limited section of a rat abdomen with well-defined edges was assessed. Because of the relative small volume involved, in vivo dosimetry with TLDs was necessary in providing us information about the accuracy of the irradiation method. Three to five days prior to the start of the radiotherapy treatment, two plastic strips - each containing a TLD-dosimeter (Harshaw TLD10 LiF rods, 1 mm dia x 6 mm) sealed in polyethylene tubing, and a lead bean - were implanted in the rat abdomen. The plastic strips made a closed loop around the bowel, through the mesenterium, and were fixed with a single stitch on the inner abdominal wall. One loop was made in the hepatic area; another was made in the lower abdomen, around the rectosigmoid. Conscious animals were irradiated using a purpose-build plexi-holder, with rear legs immobilised to avoid longitudinal movements. The implanted lead beans enabled us to simulate the rat prior to each radiation session. This way, the radiation field could be set up individually for each rat, in such way that the rectosigmoid area received full dose and the hepatic area received no irradiation dose at all. Irradiation was carried out, using 5 MV photons of a linear accelerator. Fifteen animals per group were irradiated according a conventional (2.0 Gy / fraction; 5 fractions / week) or a hyperfractionated (1.6 Gy / fraction; 2 daily fractions; 5 days / week) schedule, with different total doses. Prior to implantation, TLDs were individually calibrated and checked for stability. After removal from the abdomen . TLDs were tested again for accuracy. TLDs with an unacceptable read-out curve were rejected (about 2 to 4 TLDs per group of 15). The obtained accumulated doses - as determined by TLD read-outs-were comparable to the theoretical doses, indicating that fractionated radiation of small fields, with well defined mark off, in rats is feasible.

  10. In vivo dosimetry of high-dose fractionated irradiation in an experimental set-up with rats

    International Nuclear Information System (INIS)

    Fortan, L.; Van Hecke, H.; Van Duyse, B.; De Neve, W.; De Meerleer, B.; Pattyn, P.; Van Renthergem, K.

    1995-01-01

    The feasibility to irradiate a limited section of a rat abdomen with well-defined edges was assessed. Because of the relative small volume involved, in vivo dosimetry with TLDs was necessary in providing us information about the accuracy of the irradiation method. Three to five days prior to the start of the radiotherapy treatment, two plastic strips - each containing a TLD-dosimeter (Harshaw TLD10 LiF rods, 1 mm dia x 6 mm) sealed in polyethylene tubing, and a lead bean - were implanted in the rat abdomen. The plastic strips made a closed loop around the bowel, through the mesenterium, and were fixed with a single stitch on the inner abdominal wall. One loop was made in the hepatic area; another was made in the lower abdomen, around the rectosigmoid. Conscious animals were irradiated using a purpose-build plexi-holder, with rear legs immobilised to avoid longitudinal movements. The implanted lead beans enabled us to simulate the rat prior to each radiation session. This way, the radiation field could be set up individually for each rat, in such way that the rectosigmoid area received full dose and the hepatic area received no irradiation dose at all. Irradiation was carried out, using 5 MV photons of a linear accelerator. Fifteen animals per group were irradiated according a conventional (2.0 Gy / fraction; 5 fractions / week) or a hyperfractionated (1.6 Gy / fraction; 2 daily fractions; 5 days / week) schedule, with different total doses. Prior to implantation, TLDs were individually calibrated and checked for stability. After removal from the abdomen . TLDs were tested again for accuracy. TLDs with an unacceptable read-out curve were rejected (about 2 to 4 TLDs per group of 15). The obtained accumulated doses - as determined by TLD read-outs-were comparable to the theoretical doses, indicating that fractionated radiation of small fields, with well defined mark off, in rats is feasible

  11. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  12. Heavy ion time-of-flight ERDA of high dose metal implanted germanium

    Energy Technology Data Exchange (ETDEWEB)

    Dytlewski, N.; Evans, P.J.; Noorman, J.T. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Wielunski, L.S. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Lindfield, NSW (Australia). Div. of Applied Physics; Bunder, J. [New South Wales Univ., Wollongong, NSW (Australia). Wollongong Univ. Coll

    1996-12-31

    With the thick Ge substrates used in ion implantation, RBS can have difficulty in resolving the mass-depth ambiguities when analysing materials composed of mixtures of elements with nearly equal masses. Additional, and complimentary techniques are thus required. This paper reports the use of heavy ion time-of-flight elastic recoil detection analysis (ToF- ERDA), and conventional RBS in the analysis of Ge(100) implanted with high dose Ti and Cu ions from a MEWA ion source . Heavy ion ToF ERDA has been used to resolve, and profile the implanted transition metal species, and also to study any oxygen incorporation into the sample resulting from the implantation, or subsequential reactions with air or moisture. This work is part of a study on high dose metal ion implantation of medium atomic weight semiconductor materials. 13 refs., 6 figs.

  13. Heavy ion time-of-flight ERDA of high dose metal implanted germanium

    Energy Technology Data Exchange (ETDEWEB)

    Dytlewski, N; Evans, P J; Noorman, J T [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Wielunski, L S [Commonwealth Scientific and Industrial Research Organisation (CSIRO), Lindfield, NSW (Australia). Div. of Applied Physics; Bunder, J [New South Wales Univ., Wollongong, NSW (Australia). Wollongong Univ. Coll

    1997-12-31

    With the thick Ge substrates used in ion implantation, RBS can have difficulty in resolving the mass-depth ambiguities when analysing materials composed of mixtures of elements with nearly equal masses. Additional, and complimentary techniques are thus required. This paper reports the use of heavy ion time-of-flight elastic recoil detection analysis (ToF- ERDA), and conventional RBS in the analysis of Ge(100) implanted with high dose Ti and Cu ions from a MEWA ion source . Heavy ion ToF ERDA has been used to resolve, and profile the implanted transition metal species, and also to study any oxygen incorporation into the sample resulting from the implantation, or subsequential reactions with air or moisture. This work is part of a study on high dose metal ion implantation of medium atomic weight semiconductor materials. 13 refs., 6 figs.

  14. Surface sputtering in high-dose Fe ion implanted Si

    International Nuclear Information System (INIS)

    Ishimaru, Manabu

    2007-01-01

    Microstructures and elemental distributions in high-dose Fe ion implanted Si were characterized by means of transmission electron microscopy and Rutherford backscattering spectroscopy. Single crystalline Si(0 0 1) substrates were implanted at 350 deg. C with 120 keV Fe ions to fluences ranging from 0.1 x 10 17 to 4.0 x 10 17 /cm 2 . Extensive damage induced by ion implantation was observed inside the substrate below 1.0 x 10 17 /cm 2 , while a continuous iron silicide layer was formed at 4.0 x 10 17 /cm 2 . It was found that the spatial distribution of Fe projectiles drastically changes at the fluence between 1.0 x 10 17 and 4.0 x 10 17 /cm 2 due to surface sputtering during implantation

  15. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  16. Comparative study of SOI/Si hybrid substrates fabricated using high-dose and low-dose oxygen implantation

    International Nuclear Information System (INIS)

    Dong Yemin; Chen Meng; Chen Jing; Wang Xiang; Wang Xi

    2004-01-01

    Hybrid substrates comprising both silicon-on-insulator (SOI) and bulk Si regions have been fabricated using the technique of patterned separation by implantation of oxygen (SIMOX) with high-dose (1.5 x 10 18 cm -2 ) and low-dose ((1.5-3.5) x 10 17 cm -2 ) oxygen ions, respectively. Cross-sectional transmission electron microscopy (XTEM) was employed to examine the microstructures of the resulting materials. Experimental results indicate that the SOI/Si hybrid substrate fabricated using high-dose SIMOX is of inferior quality with very large surface height step and heavily damaged transitions between the SOI and bulk regions. However, the quality of the SOI/Si hybrid substrate is enhanced dramatically by reducing the implant dose. The defect density in transitions is reduced considerably. Moreover, the expected surface height difference does not exist and the surface is exceptionally flat. The possible mechanisms responsible for the improvements in quality are discussed

  17. Effects of high-dose hydrogen implantation on defect formation and dopant diffusion in silver implanted ZnO crystals

    Energy Technology Data Exchange (ETDEWEB)

    Yaqoob, Faisal [Department of Physics, State University of New York at Albany, Albany, New York 12222 (United States); Huang, Mengbing, E-mail: mhuang@sunypoly.edu [College of Nanoscale Science and Engineering, State University of New York Polytechnic Institute, Albany, New York 12203 (United States)

    2016-07-28

    This work reports on the effects of a deep high-dose hydrogen ion implant on damage accumulation, defect retention, and silver diffusion in silver implanted ZnO crystals. Single-crystal ZnO samples were implanted with Ag ions in a region ∼150 nm within the surface, and some of these samples were additionally implanted with hydrogen ions to a dose of 2 × 10{sup 16 }cm{sup −2}, close to the depth ∼250 nm. Rutherford backscattering/ion channeling measurements show that crystal damage caused by Ag ion implantation and the amount of defects retained in the near surface region following post-implantation annealing were found to diminish in the case with the H implantation. On the other hand, the additional H ion implantation resulted in a reduction of substitutional Ag atoms upon post-implantation annealing. Furthermore, the presence of H also modified the diffusion properties of Ag atoms in ZnO. We discuss these findings in the context of the effects of nano-cavities on formation and annihilation of point defects as well as on impurity diffusion and trapping in ZnO crystals.

  18. Two-generation reproductive toxicity study of implanted depleted uranium (DU) in CD rats.

    Science.gov (United States)

    Arfsten, D P; Still, K R; Wilfong, E R; Johnson, E W; McInturf, S M; Eggers, J S; Schaeffer, D J; Bekkedal, M Y-V

    2009-01-01

    groups. Eight of 414 F1 animals observed from PND 20 to 120 died of unknown causes; 7 were from litters of DU-implanted F0 mating pairs. F1 mating success at 10 wk of age was an overall 70% compared with 91% for F0 mating pairs. Mating success was similar between F1 animals derived from DU-implanted F0 adults and those derived from F0 implant control adults suggesting that the comparatively low mating success was not due to F1 DU exposure. The gestational index of F1 animals derived from mid-dose F0 mating pairs was found to be lower compared with F1 controls. The average gestation duration of F1 animals derived from high-dose F0 mating pairs was found to be significantly longer than F1 controls. F1 sperm motility analyses did not differ among experimental groups and no gross abnormalities were identified at necropsy among surviving F1 animals at PND 120. Histopathology of kidneys, spleen, thymus, bone marrow, ovaries, and testes of F1 high-dose animals did not differ from F1 controls. F1 high-dose females had significantly higher mean relative liver and heart weights compared with F1 controls; the biological relevance of this finding could not be determined. For the F2 generation, measures of F2 development through PND 20 were unremarkable and no gross abnormalities were observed in F2 offspring. Necropsy findings of F2 PND 20 pups were negative and no instances of ribcage malformation were observed in F2 PND 20 pups. Body weight and body weight gain of F2 rats through PND 90 were similar across treatment groups. Mean relative heart weights of males derived from high-dose F0 parents were significantly lower compared with F2 controls. Sperm motility and concentration analysis of F2 males at PND 90 were similar across F2 groups. Overall, the consistent absence of positive findings in this study seems to suggest that DU is not a significant reproductive or developmental hazard, particularly when one considers that mid- and high-dose rats were implanted with the equivalent

  19. High-dose V+ implantation in ZnO thin film structures

    International Nuclear Information System (INIS)

    Vyatkin, A.F.; Zinenko, V.I.; Agaphonov, Yu.A.; Pustovit, A.N.; Roshchupkin, D.V.; Reuss, F.; Kirchner, C.; Kling, R.; Waag, A.

    2005-01-01

    In the last two decades, diluted magnetic semiconductors have attracted great attention as promising materials for spintronics applications. [K. Sato, H. Katyama-Yoshida, Jpn. J. Phys., Part 2 39 (2000) L555] theoretically predicted that ZnO doped with V, Cr, Fe, Co, and Ni can be ferromagnetic. This has been recently confirmed experimentally for vanadium doped ZnO films which were grown on sapphire substrates, using laser deposition technique [H. Saeki, H.N. Tabata, T. Kawai, Solid State Commun. 120 (2001) 439]. In the present work, high-dose vanadium implantation was used to produce Zn 1-x V x O (x ∼ 0.10) thin film structures (250 nm thick) that had been epitaxially grown on sapphire substrates. Implantation with the dose 2 x 10 16 cm -2 was performed to reach a maximum vanadium concentration of 10 at%. To avoid ZnO film amorphization due to radiation damage accumulation [S.O. Kucheyev, J.S. Williams, C. Jagadish, J. Zou, C. Evans, A.J. Nelson, A.V. Hamza, Phys. Rev. B 67 (2003) 094115], all implants were done at elevated temperatures 300 and 400 deg. C and ion current density 10 μA/cm 2 . X-ray diffraction, SIMS and photoluminescence techniques were exploited to study the implanted samples. No luminescence was observed in the implanted samples after implantation procedures. However, annealing at 800 deg. C for 30 min gave rise to ZnO crystal structure improvement. This implies that healing of implantation induced defects is possible even after heavy-ion bombardment. As a result, the photoluminescence peak at 3.359 eV related to the donorbound exiton was detected

  20. X-ray photoelectron spectroscopy characterization of high dose carbon-implanted steel and titanium alloys

    Science.gov (United States)

    Viviente, J. L.; García, A.; Alonso, F.; Braceras, I.; Oñate, J. I.

    1999-04-01

    A study has been made of the depth dependence of the atomic fraction and chemical bonding states of AISI 440C martensitic stainless steel and Ti-6Al-4V alloy implanted with 75 keV C + at very high doses (above 10 18 ions cm -2), by means of X-ray photoelectron spectroscopy combined with an Ar + sputtering. A Gaussian-like carbon distribution was observed on both materials at the lowest implanted dose. More trapezoidal carbon depth-profiles were found with increasing implanted doses, and a pure carbon layer was observed only on the titanium alloy implanted at the highest dose. The implanted carbon was combined with both base metal and carbon itself to form metallic carbides and graphitic carbon. Furthermore, carbon-enriched carbides were also found by curve fitting the C 1s spectra. The titanium alloy showed a higher carbidic contribution than the steel implanted at the same C + doses. A critical carbon concentrations of about 33 at.% and 23 at.% were measured for the formation of C-C bonds in Ti-6Al-4V and steel samples, respectively. The carbon atoms were bound with metal to form carbidic compounds until these critical concentrations were reached; when this C concentration was exceeded the proportion of C-C bonds increased and resulted in the growth of carbonaceous layers.

  1. Application of TXRF for ion implanter dose matching experiments

    Science.gov (United States)

    Frost, M. R.; French, M.; Harris, W.

    2004-06-01

    Secondary ion mass spectrometry (SIMS) has been utilized for many years to measure the dose of ion implants in silicon for the purpose of verifying the ability of ion implantation equipment to accurately and reproducibly implant the desired species at the target dose. The development of statistically and instrumentally rigorous protocols has lead to high confidence levels, particularly with regard to accuracy and short-term repeatability. For example, high-dose, high-energy B implant dosimetry can be targeted to within ±1%. However, performing dose determination experiments using SIMS does have undesirable aspects, such as being highly labor intensive and sample destructive. Modern total reflection X-ray fluorescence (TXRF) instruments are equipped with capabilities for full 300 mm wafer handling, automated data acquisition software and intense X-ray sources. These attributes enable the technique to overcome the SIMS disadvantages listed above, as well as provide unique strengths that make it potentially highly amenable to implanter dose matching. In this paper, we report on data collected to date that provides confidence that TXRF is an effective and economical method to perform these measurements within certain limitations. We have investigated a number of ion implanted species that are within the "envelope" of TXRF application. This envelope is defined by a few important parameters. Species: For the anode materials used in the more common X-ray sources on the market, each has its own set of elements that can be detected. We have investigated W and Mo X-ray sources, which are the most common in use in commercial instrumentation. Implant energy: In general, if the energy of the implanted species is too high (or more specifically, the distribution of the implanted species is too deep), the amount of dopant not detected by TXRF may be significant, increasing the error of the measurement. Therefore, for each species investigated, the implant energy cannot exceed a

  2. 192Ir high dose rate (HDR) interstitial brain implant: optimisation

    International Nuclear Information System (INIS)

    Tyagi, Anuj; Singh, Dinesh; Chitra, S.; Gupta, J.P.

    2001-01-01

    The new modality of stepping source dosimetry system (SSDs) illustrates a remarkable improvement in attaining the uniform and homogeneous dose distribution within the target volume. The technique enables the physicist to correct for a certain amount of misplacement or curvature of implant geometry. The short course of brachytherapy provides good palliation in terms of functional improvements with low and acceptable toxicity in high-grade glioma. With continual refinements of the technique, brachytherapy performed by a skilled brachytherapy team offers an opportunity to improve patient survival and quality of life. Since 1997, micro selectron HDR 192 Ir treatments are done including gynecological, oesophageal, breast, surface mould, soft tissue sarcoma (STS) and brain in our hospital. In this paper, procedure of interstitial brain implant in glioma as implant technique, simulation and treatment planning will be discussed

  3. Extreme implanting in Si: A study of ion-induced damage at high temperature and high dose

    International Nuclear Information System (INIS)

    Holland, O.W.

    1994-01-01

    Ion-solid interactions near room temperature and below have been well studied in single-crystal Si. While this has led to a better understanding of the mechanisms responsible for nucleation and growth of lattice damage during irradiation, these studies have not, in general, been extended to high temperatures (e.g., >200 degrees C). This is the case despite the commercialization of ion beam technologies which utilize high-temperature processing, such as separation by implantation of oxygen (SIMOX). In this process, a silicon-on-insulator (SOI) material is produced by implanting a high dose of oxygen ions into a Si wafer to form a buried, stoichiometric oxide layer. Results will be presented of a study of damage accumulation during high-dose implantation of Si at elevated temperatures. In particular, O + -ions were used because of the potential impact of the results on the SIMOX technology. It will be shown that the nature of the damage accumulation at elevated temperatures is quite distinctive and portends the presence of a new mechanism, one which is only dominant under the extreme conditions encountered during ion beam synthesis (i.e., high temperature and high dose). This mechanism is discussed and shown to be quite general and not dependent on the chemical identity of the ions. Also, techniques for suppressing this mechanism by open-quotes defect engineeringclose quotes are discussed. Such techniques are technologically relevant because they offer the possibility of reducing the defect density of the SOI produced by SIMOX

  4. Improved ovulation rate and implantation in rats treated with royal jelly

    African Journals Online (AJOL)

    The ovaries and uteris of 12 mature female rats (Rattus norvegicus) were examined to determine the effect of commercial royal jelly on ovulation, ovarian weight and implantation rates. Rats were split in two groups of 6 each. Group one served as the treatment and group two the control. A daily dose of 25mg of royal jelly ...

  5. High dose implantations of antimony for buried layer applications

    International Nuclear Information System (INIS)

    Gailliard, J.P.; Dupuy, M.; Garcia, M.; Roussin, J.C.

    1978-01-01

    Electrical and physical properties of high dose implantations of antimony in silicon have been studied for use in buried layer applications. The results have been obtained both on and oriented silicon wafers. Following implantations which lead to amorphization we perform an annealing at 600 0 C for 10 mn in order to recrystallize the layer. The observed electrical properties (μ, R) show that the concentration of electrically active antimony ions is greater than that predicted from the solubility of antimony in silicon. Further annealing (in the range 1050 0 - 1200 0 ) induces: firstly a precipitation of the Sb and secondly a diffusion and dissolution of the precipitates. There is a different evolution of the defects in the and silicon slices. T.E.M. reveals no defects in the wafers after one hour annealing at 1200 0 C, whereas defects and twins remain in wafers. Having obtained the evolution of R with time and temperature it is then determined the implantation and annealing conditions which lead to the low resistivity (R = 10) needed for buried layer applications. Results with very many industrially made devices are discussed

  6. Structural-phase changes of α-Fe implanted with high ion doses

    International Nuclear Information System (INIS)

    Ivanov, Y.F.; Pogrebnyak, A.; Martynenko, V.

    2001-01-01

    The CEMS method was used to examine and implanted layer of α-Fe with a thickness of up to 100 nm. The radiation of α-Fe with carbon ions results of the formation of the solid solution of carbon in α-Fe and the precipitation of the iron carbides Fe 2 C. The implantation of aluminium in the α-Fe is accompanied by the formation of the order phase Fe 3 Al. The results of show that the phase the composition of the surface layer of α-Fe, irradiated with titanium, is represented by the solid solution of the titanium in α-Fe, and also by the micro-clusters of iron characterised by different environment of the titanium atoms of the level of several co-ordination spheres. The presence of these micro-clusters indicates the non-uniform distribution of titanium in α-Fe. The additional Auger analysis of the specimens of α-Fe, implanted with titanium with a dose of 5 x 10 -17 cm -2 , showed a high concentration of carbon (up to 20 at.%) in the layer up to 50 nm thick. The authors of 2 assumed that the carbon, implanted from the residual atmosphere, affects not only the resultant profile of the distribution of titanium in the depth of α-Fe, but also the change of the physical-mechanical properties of the surface layer. The main aim of the investigations was to examine the phase composition and the formation of secondary defects (dislocations and dislocation sub structures) in the surface layer of α-Fe, implanted with titanium, aluminium, carbon, with a dose of 5 x 10 -17 cm -2

  7. Cavities at the Si projected range by high dose and energy Si ion implantation in Si

    International Nuclear Information System (INIS)

    Canino, M.; Regula, G.; Lancin, M.; Xu, M.; Pichaud, B.; Ntzoenzok, E.; Barthe, M.F.

    2009-01-01

    Two series of n-type Si samples α and β are implanted with Si ions at high dose (1 x 10 16 ) and high energies, 0.3 and 1.0 MeV, respectively. Both sort of samples are then implanted with 5 x 10 16 He cm -2 (at 10 or 50 keV) and eventually with B atoms. Some of the samples are annealed at temperatures ranging from 800 to 1000 deg. C to allow the thermal growth of He-cavities, located between sample surface and the projected range (R p ) of Si. After the triple ion implantation, which corresponds to defect engineering, samples were characterized by cross-section transmission electron microscopy (XTEM). Voids (or bubbles) are observed not only at the R p (He) on all annealed samples, but also at the R p (Si) on β samples implanted with He at 50 keV. The samples are also studied by positron annihilation spectroscopy (PAS) and the spectra confirm that as-implanted samples contain di-vacancies and that the annealed ones, even at high temperature have bigger open volumes, which are assumed to be the same voids observed by XTEM. It is demonstrated that a sole Si implantation at high energy and dose is efficient to create cavities which are thermally stable up to 1000 deg. C only in the presence of He.

  8. A study of enhanced diffusion during high dose high flux pulsed metal ion implantation into steel and aluminium

    International Nuclear Information System (INIS)

    Zhang Tonghe; Ji Chengzhou; Shen Jinghua; Chen Jun

    1992-01-01

    The depth profiles of metal ions implanted into steel and aluminium were measured by Rutherford backscattering (RBS). The ions of Mo, W and Y, produced by a metal vapour vacuum are ion source (MEVVA) were implanted at an energy range from 25 to 50 keV for doses of (2-5)x10 17 cm -2 into H13 steel and aluminium. Beam currents were from 0.5 to 1.0 A. The beam flux is in the range of 25 to 75 μAcm -2 . In order to simulate the profiles, a formula which includes the sputtering yield, diffusion coefficients and reaction rate was obtained. The results demonstrate that the penetration depth and retained dose increase with increasing beam flux for Mo implanted into aluminium. The peak concentration of Mo implanted H13 steel increases with increasing ion flux. In contrast to this for Y implantation into steel, the peak concentration of Y decreases with increasing ion flux. For an ion flux of 25 μAcm -2 for Mo, Y and W implantation into steel, the penetration depth and retained dose are 3-5 times greater than the theoretical values. The diffusion coefficients are about 10 -16 to 10 -15 s -1 . If the ion flux is greater than 47 μAcm -2 , the penetration depth and retained dose are 5 to 10 times greater than the theoretical values for Mo implanted aluminium. The diffusion coefficients increase with increasing ion flux for Mo implanted aluminium. The diffusion coefficients hardly change with increasing ion flux for Y and Mo implanted H13 steel. The retained dose increases 0.43 to 1.16 times for Y implanted steel for an ion flux of 25 μAcm -2 . Finally, the influence of phases precipitates, reaction rate and diffusion on retained dose, diffusion coefficient and penetration depth are discussed. (orig.)

  9. Evaluation of Geometrically Optimized Single- and Double-plane Interstitial High Dose Rate Implants with Respect to Conformality and Homogeneity

    International Nuclear Information System (INIS)

    Major, Tibor; Polgar, Csaba; Fodor, Janos; Takacsi-nagy, Zoltan; Mangel, Laszlo; Nemeth, Gyoergy

    2003-01-01

    The use of a stepping source in high dose rate brachytherapy supported with dwell-time optimization makes it possible to deviate from the classical dosimetry systems. Dose distributions of single- and double-plane implants were analysed for conformality and homogeneity at idealized target volumes. The Paris system was used for catheter positioning and target volume determination. Geometric optimization and individual dose prescription were applied. Volumetric indices and dose parameters were calculated at optimal active length, which was found to be equal to target volume length. The mean conformality, homogeneity, external volume and overdose volume indices were 0.78, 0.67, 0.22 and 0.13, respectively. The average minimum target and reference doses were 69% and 86%, respectively. Comparisons between the volumetric indices of geometrical optimized and non-optimized implants were also performed, and a significant difference was found regarding any index. The geometrical optimization resulted in superior conformality and slightly inferior homogeneity. At geometrically optimized implants, the active length can be reduced compared to non-optimized implants. Volumetric parameters and dose-volume histogram-based individual dose prescription are recommended for quantitative assessment of interstitial implants

  10. Effect of osteoporosis on fixation of osseointegrated implants in rats.

    Science.gov (United States)

    Li, Yunfeng; He, Sheng; Hua, Yunwei; Hu, Jing

    2017-11-01

    The effect of osteoporosis on implant osseointegration has been widely investigated, whereas osteoporosis may also newly occur in patient with previously osseointegrated implant. This study was designed to investigate the effect of osteoporosis on implant fixation in rats after successful osseointegration had been obtained. Seventy female Sprague-Dawley rats were included, and each animal received two titanium implants in the distal metaphysis of femur bilaterally. Eight weeks later, ten rats were sacrificed to confirm the establishment of implant osseointegration. All left rats were randomly subjected to bilateral ovariectomy (OVX) or sham operation. Three, six, and twelve weeks later, implant osseointegration, peri-implant bone tissue, and biomechanical properties of implant were analyzed. Right femurs with implants were used for micro-CT and histological analysis, and left femurs with implants were used for biomechanical test. Micro-CT, histology, and biomechanical test confirmed the destructive effect of OVX on previously osseointegrated implant in rats; when compared to sham-operated rats, peri-implant bone volume, trabecular architecture, bone-to-implant contact ratio, as well as biomechanical parameters decreased progressively within 12 weeks. Results also indicated that the effect of OVX on undisturbed bone (proximal tibiae) was much stronger than that on peri-implant bone. Osteoporosis produced a progressive negative effect on previously osseointegrated implant in distal femora of rats during 12 weeks. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2426-2432, 2017. © 2016 Wiley Periodicals, Inc.

  11. Dietary intake of high-dose biotin inhibits spermatogenesis in young rats.

    Science.gov (United States)

    Sawamura, Hiromi; Ikeda, Chieko; Shimada, Ryoko; Yoshii, Yui; Watanabe, Toshiaki

    2015-02-01

    To characterize a new function of the water-soluble vitamin, biotin, in reproduction and early growth in mammals, the effects of high dietary doses of biotin on early spermatogenesis were biochemically and histologically investigated in male rats. Weaned rats were fed a CE-2 (control) diet containing 0.00004% biotin, or a control diet supplemented with 0.01%, 0.1%, or 1.0% biotin. Pair-fed rats were fed a control diet that was equal in calories to the amount ingested by the 1.0% biotin group, because food intake was decreased in the 1.0% biotin group. Food intake and body weight gain were lower in the 1.0% biotin group than in the control group. The kidney, brain and testis weights were significantly lower in the 1.0% biotin group than in the pair-fed group after 6 weeks of feeding. The accumulation of biotin in the liver and testis increased in a dose-dependent manner. In the 1.0% biotin group, the number of mature sperm was markedly lower, that of sperm with morphologically abnormal heads, mainly consisting of round heads, had increased. In addition, the development of seminiferous tubules was inhibited, and few spermatogonia and no spermatocytes were histologically observed. These results demonstrated that the long-term intake of high-dose biotin inhibited spermatogenesis in young male rats. © 2014 Japanese Teratology Society.

  12. Proconvulsant effects of high doses of venlafaxine in pentylenetetrazole-convulsive rats

    Directory of Open Access Journals (Sweden)

    J.G. Santos Junior

    2002-04-01

    Full Text Available Venlafaxine, an atypical antidepressant drug, has been used to treat several neurological disorders, presenting excellent efficacy and tolerability. Clinical seizures after venlafaxine treatment have occasionally been reported when the drug was used at very high doses or in combination with other medications. The aim of the present study was to investigate the convulsant effects of venlafaxine in rats under controlled laboratory conditions. Adult male Wistar rats (8 per group receiving venlafaxine or saline at the doses of 25-150 mg/kg were subjected 30 min later to injections of pentylenetetrazole at the dose of 60 mg/kg. The animals receiving 75, 100 and 150 mg/kg venlafaxine presented increased severity of convulsion when compared to controls (P = 0.02, P = 0.04, and P = 0.0004, respectively. Indeed, an increased percentage of death was observed in these groups (50, 38, and 88%, respectively when compared to the percentage of death in the controls (0%. The group receiving 150 mg/kg showed an reduction in death latency (999 ± 146 s compared to controls (1800 ± 0 s; cut-off time. Indeed, in this group, all animals developed seizures prior to pentylenetetrazole administration. Surprisingly, the groups receiving venlafaxine at the doses of 25 and 50 mg/kg showed a tendency towards an increase in the latency to the first convulsion. These findings suggest that venlafaxine at doses of 25 and 50 mg/kg has some tendency to an anticonvulsant effect in the rat, whereas doses of 75, 100 and 150 mg/kg presented clear proconvulsant effects in rats submitted to the pentylenetetrazole injection. These findings are the first report in the literature concerning the role of venlafaxine in seizure genesis in the rat under controlled conditions.

  13. Positron annihilation studies of silicon-rich SiO2 produced by high dose ion implantation

    International Nuclear Information System (INIS)

    Ghislotti, G.; Nielsen, B.; Asoka-Kumar, P.; Lynn, K.G.; Di Mauro, L.F.; Corni, F.; Tonini, R.

    1997-01-01

    Positron annihilation spectroscopy (PAS) is used to study Si-rich SiO 2 samples prepared by implantation of Si (160 keV) ions at doses in the range 3x10 16 endash 3x10 17 cm -2 and subsequent thermal annealing at high temperature (up to 1100 degree C). Samples implanted at doses higher than 5x10 16 cm -2 and annealed above 1000 degree C showed a PAS spectrum with an annihilation peak broader than the unimplanted sample. We discuss how these results are related to the process of silicon precipitation inside SiO 2 . copyright 1997 American Institute of Physics

  14. Gamma radiation and its role in bio prosthetic aortic valves implanted in rat hearts

    International Nuclear Information System (INIS)

    Lamas, Gloria I.; Kairiyama, Eulogia; Navia, Jose

    2000-01-01

    Porcine heart valves glutaraldehyde fixed are implanted in patients with valvular deterioration. Mineralization may be the major factor in the long-term failure of tissue bio prosthesis. Gamma radiation randomly breaks some glutaraldehyde cross-links. As a consequence of irradiation, the polymeric fibers belonging to the valvular tissue are broken too, leading to sites of collagen fiber disorganisation. It is well known that the collagen fibers may act as a passive nucleator of salts where the calcium phosphate salts precipitate. This salt concentration has been described in association with disintegrated sites of protein fiber, which may favour new sites where the calcium salts would be deposit. The irradiation process is a technique used for sterilization of porcine heart valve. The main objective of this work was to study the effect of different doses of gamma radiation on the calcification process of subcutaneously implanted valves in rats. Small pieces from glutaraldehyde fixed valves, irradiated to different doses with a 60 Co sources were implanted subcutaneously in rats. The calcium was measured by X-ray and atomic absorption spectrophotometry. In our experimental conditions and at the radiation doses used in these tests, the calcium measurements on control and irradiated material were not significantly different. We conclude that, at the employed doses, the gamma radiation does not alter the process. (author) [es

  15. Annealing behaviour of high-dose rare-gas implantations into silicon

    International Nuclear Information System (INIS)

    Williams, J.S.; Grant, W.A.

    1976-01-01

    The annealing behaviour of 13 -10 17 ions/cm 2 is investigated by RBS and channelling techniques. There appears to be a strong correlation between the degree and nature of the post-anneal (above 650 0 C) remnant Si disorder, the implanted gas concentration and subsequent out-diffusion of the gas species. During the out-diffusion process a fraction of the gas (always less than 10 15 cm -2 ) remains trapped at, or beyond, the ion range and some of the diffusing gas becomes trapped near the target surface; for implantation doses below 10 15 cm -2 , no out-diffusion is observed up to 850 0 C. This behaviour is discussed in terms of the defect structure of the recrystallized implant layer. (author)

  16. Ushairi wa Kiswahili kama Chombo cha Ujenzi wa Utangamano wa ...

    African Journals Online (AJOL)

    Makala haya yanafafanua dhima ya ushairi wa Kiswahili katika kujenga uwiano na utangamano katika jamii. Maendeleo na ustawi wa lugha huenda sambamba na fasihi yake. Ushairi wa Kiswahili kama utanzu wa fasihi, una historia ndefu. Aidha, umaarufu wa ushairi huu hautokani tu na vipengele vya lugha teule ...

  17. Controlled localised melting in silicon by high dose germanium implantation and flash lamp annealing

    International Nuclear Information System (INIS)

    Voelskow, Matthias; Skorupa, Wolfgang; Pezoldt, Joerg; Kups, Thomas

    2009-01-01

    High intensity light pulse irradiation of monocrystalline silicon wafers is usually accompanied by inhomogeneous surface melting. The aim of the present work is to induce homogeneous buried melting in silicon by germanium implantation and subsequent flash lamp annealing. For this purpose high dose, high energy germanium implantation has been employed to lower the melting temperature of silicon in a predetermined depth region. Subsequent flash lamp irradiation at high energy densities leads to local melting of the germanium rich buried layer, whereby the thickness of the molten layer depends on the irradiation energy density. During the cooling down epitaxial crystallization takes place resulting in a largely defect-free layer. The combination of buried melting and dopant segregation has the potential to produce unusually buried doping profiles or to create strained silicon structures.

  18. Dose distribution close to metal implants in Gamma Knife Radiosurgery: A Monte Carlo study

    International Nuclear Information System (INIS)

    Cheung, Joel Y.C.; Yu, K.N.; Chan, Josie F.K.; Ho, Robert T.K.; Yu, C.P.

    2003-01-01

    Materials with high atomic numbers favor the occurrence of the photoelectric effect when they are irradiated with gamma rays. Therefore, the photoelectric effects of metal implants within the target regions in Gamma Knife Radiosurgery are worth studying. In the present work, Monte Carlo simulations using EGS4 were employed to investigate the resulting dose enhancements. A dose enhancement as high as 10% was observed close to a platinum implant along the x and y axes, while no significant dose enhancements were observed for silver, stainless steel 301, and titanium ones. A dose enhancement as high as 20% was observed close to the platinum implant along the z axis at the superior position of the metal-phantom interface and was 10% higher for other metal implants

  19. High-dose fasudil preserves postconditioning against myocardial infarction under hyperglycemia in rats: role of mitochondrial KATP channels

    Directory of Open Access Journals (Sweden)

    Ichinomiya Taiga

    2012-03-01

    Full Text Available Abstract Background The current study was carried out to determine whether fasudil hydrochloride (fasudil, a Rho-kinase inhibitor, has myocardial postconditioning (PostC activity under hyperglycemia as well as normoglycemia, and if so, whether the effects could be mediated by mitochondrial ATP-sensitive potassium (m-KATP channels. Methods Male Sprague-Dawley rats were anesthetized with sodium pentobarbital. After opening the chest, all rats underwent 30-min coronary artery occlusion followed by 2-h reperfusion. The rats received low-dose (0.15 mg/kg or high-dose (0.5 mg/kg fasudil or diazoxide, an m-KATP channel opener, at 10 mg/kg, just before reperfusion under normoglycemic or hyperglycemic conditions. In another group, rats received 5-hydroxydecanoic acid (5HD, an m-KATP channel blocker, at 10 mg/kg, before high-dose fasudil. Myocardial infarct size was expressed as a percentage of area at risk (AAR. Results Under normoglycemia, low-dose and high-dose fasudil and diazoxide reduced myocardial infarct size (23 ± 8%, 21 ± 9% and 21 ± 10% of AAR, respectively compared with that in the control (42 ± 7%. Under hyperglycemia, low-dose fasudil (40 ± 11% and diazoxide (44 ± 14% could not exert this beneficial effect, but high-dose fasudil reduced myocardial infarct size in the same manner as under normoglycemia (21 ± 13%. 5HD prevented fasudil-induced reduction of myocardial infarct size (42 ± 13%. Conclusion Fasudil induces PostC against myocardial infarction via activation of m-KATP channels in the rat. Although hyperglycemia attenuates the PostC, high-dose fasudil can restore cardioprotection.

  20. Immune responses to implanted human collagen graft in rats

    International Nuclear Information System (INIS)

    Quteish, D.; Dolby, A.E.

    1991-01-01

    Immunity to collagen implants may be mediated by cellular and humoral immune responses. To examine the possibility of such immunological reactivity and crossreactivity to collagen, 39 Sprague-Dawley rats (female, 10 weeks old, approximately 250 g wt) were implanted subcutaneously at thigh sites with crosslinked, freeze-dried human placental type I collagen grafts (4x4x2 mm) which had been irradiated (520 Gray) or left untreated. Blood was obtained by intracardiac sampling prior to implantation or from normal rats, and at various times afterwards when the animals were sacrificed. The sera from these animals were examined for circulating antibodies to human, bovine and rat tail (type I) collagens by enzyme-linked immunosorbent assay (ELISA). Also, the lymphoblastogenic responses of spleen lymphocytes from the irradiated collagen-implanted animals were assessed in culture by measuring thymidine uptake with autologous and normal rat sera in the presence of human bovine type I collagens. Implantation of the irradiated and non-irradiated collagen graft in rats led to a significant increase in the level of circulating antibodies to human collagen. Also antibody to bovine and rat tail collagens was detectable in the animals implanted with irradiated collagen grafts but at a lower level than the human collagen. There was a raised lymphoblastogenic response to both human and bovine collagens. The antibody level and lymphoblastogenesis to the tested collagens gradually decreased towards the end of the post-implantation period. (author)

  1. Absorption, Distribution, and Excretion of 14C-APX001 after Single-Dose Administration to Rats and Monkeys

    OpenAIRE

    Mansbach, Robert; Shaw, Karen J; Hodges, Michael R; Coleman, Samantha; Fitzsimmons, Michael E

    2017-01-01

    Abstract Background APX001 is a small-molecule therapeutic agent in clinical development for the treatment of invasive fungal infections (IFI). Methods The absorption, distribution and excretion profiles of [14C]APX001-derived radioactivity were determined in rats (albino and pigmented) and monkeys. Rats (some implanted with bile duct cannulae) were administered a single 100 mg/kg oral dose or a 30 mg/kg intravenous (IV) dose. Monkeys were administered a single 6 mg/kg IV dose. Samples of blo...

  2. Formation of copper silicides by high dose metal vapor vacuum arc ion implantation

    International Nuclear Information System (INIS)

    Rong Chun; Zhang Jizhong; Li Wenzhi

    2003-01-01

    Si(1 1 1) was implanted by copper ions with different doses and copper distribution in silicon matrix was obtained. The as-implanted samples were annealed at 300 and 540 deg. C, respectively. Formation of copper silicides in as-implanted and annealed samples were studied. Thermodynamics and kinetics of the reaction were found to be different from reaction at copper-silicon interface that was applied in conventional studies of copper-silicon interaction. The defects in silicon induced by implantation and formation of copper silicides were recognized by Si(2 2 2) X-ray diffraction (XRD)

  3. The structure and elemental composition of the SiO2 layers with zinc-based nano clusters created by high-dose implantation and annealing

    International Nuclear Information System (INIS)

    Mokhovikov, M.A.; Komarov, F.F.; Vlasukova, L.A.; Mil'chanin, O.V.; Wendler, E.; Wesch, W.; Zhukovski, P.; Vengerek, P.

    2015-01-01

    We present the results of the structure and elemental composition of the SiO 2 layers after high-dose zinc implantation (10 16 - 10 17 sm -2 ) at room temperature and at 500°C, as well as after 700°C annealing. In the case of 'hot' implantation the formation of nano sized (to 5 nm) clusters containing atoms of zinc is registered in as-implanted samples. TEM-analysis proves crystalline structure of these precipitates. Subsequent annealing results in a redistribution of zinc within the implanted layer and in the formation of large crystallites (10 -12 nm for a dose of 5*10 16 cm -2 and 12-18 nm for a dose of 10 17 cm -2 ) in the area of high impurity concentration. (authors)

  4. Synthesis of SiC microstructures in Si technology by high dose carbon implantation: Etch-stop properties

    International Nuclear Information System (INIS)

    Serre, C.; Perez-Rodriguez, A.; Romano-Rodriguez, A.; Calvo-Barrio, L.; Morante, J.R.; Esteve, J.; Acero, M.C.; Skorupa, W.; Koegler, R.

    1997-01-01

    The use of high dose carbon ion implantation in Si for the production of membranes and microstructures is investigated. Si wafers were implanted with carbon doses of 10 17 and 5 x 10 17 cm -2 , at an energy of 300 keV and a temperature of 500 C. The structural analysis of these samples revealed the formation of a highly stable buried layer of crystalline β-SiC precipitates aligned with the Si matrix. The etch-stop properties of this layer have been investigated using tetramethyl-ammonium hydroxide as etchant solution. Secondary ion mass spectrometry measurements performed on the etched samples have allowed an estimate of the minimum dose needed for obtaining an etch-stop layer to a value in the range 2 to 3 x 10 17 ions/cm 2 . This behavior has been explained assuming the existence of a percolation process in a SiC/Si binary system. Finally, very thin crystalline membranes and self-standing structures with average surface roughness in the range 6 to 7 nm have been obtained

  5. Establishment of reproducible osteosarcoma rat model using orthotopic implantation technique.

    Science.gov (United States)

    Yu, Zhe; Sun, Honghui; Fan, Qingyu; Long, Hua; Yang, Tongtao; Ma, Bao'an

    2009-05-01

    In experimental musculoskeletal oncology, there remains a need for animal models that can be used to assess the efficacy of new and innovative treatment methodologies for bone tumors. Rat plays a very important role in the bone field especially in the evaluation of metabolic bone diseases. The objective of this study was to develop a rat osteosarcoma model for evaluation of new surgical and molecular methods of treatment for extremity sarcoma. One hundred male SD rats weighing 125.45+/-8.19 g were divided into 5 groups and anesthetized intraperitoneally with 10% chloral hydrate. Orthotopic implantation models of rat osteosarcoma were performed by injecting directly into the SD rat femur with a needle for inoculation with SD tumor cells. In the first step of the experiment, 2x10(5) to 1x10(6) UMR106 cells in 50 microl were injected intraosseously into median or distal part of the femoral shaft and the tumor take rate was determined. The second stage consisted of determining tumor volume, correlating findings from ultrasound with findings from necropsia and determining time of survival. In the third stage, the orthotopically implanted tumors and lung nodules were resected entirely, sectioned, and then counter stained with hematoxylin and eosin for histopathologic evaluation. The tumor take rate was 100% for implants with 8x10(5) tumor cells or more, which was much less than the amount required for subcutaneous implantation, with a high lung metastasis rate of 93.0%. Ultrasound and necropsia findings matched closely (r=0.942; p<0.01), which demonstrated that Doppler ultrasonography is a convenient and reliable technique for measuring cancer at any stage. Tumor growth curve showed that orthotopically implanted tumors expanded vigorously with time-lapse, especially in the first 3 weeks. The median time of survival was 38 days and surgical mortality was 0%. The UMR106 cell line has strong carcinogenic capability and high lung metastasis frequency. The present rat

  6. Tribological studies of ultrahigh dose nitrogen-implanted iron and stainless steel

    International Nuclear Information System (INIS)

    Wei, R.; Wilbur, P.J.; Ozturk, O.; Williamson, D.L.

    1991-01-01

    The effects of nitrogen implantation to doses as high as 1x10 19 ions/cm 2 on the sliding wear resistance and nitrogen concentration depth profiles are examined experimentally. By maintaining the proper implantation temperature, increases in dose induce the formation of thicker nitrogen-rich, wear-resistant layers. Several microns thick layers are demonstrated for both iron and stainless steel. (orig.)

  7. The effect of x-irradiation on the implantation and development of the white rat fetus

    International Nuclear Information System (INIS)

    Danius, J.; Bahauddin, R.

    1976-01-01

    X-ray whole body irradiation (200R, exposure dose) was performed on young virgin females of about 4 months old. The female rats, divided into three groups, were treated as follows: Female rats as control (unirradiated = 1Kt): female rats irradiated before mating (RSbK), and female rats irradiated after mating (RSsK). The average number of surviving foetuses at 20 days gestational stage of 1Kt was compared with that of RSbK, and no significant difference was found (P<=0.05) while the difference between the average number of RSsK foetuses compared with that of 1Kt and RSbK was highly significant (P<0.01). A decrease in the average number of surviving foetuses was found in RSsK, although the analysis of variance of all groups, revealed no significant difference (P<=0.05) in the average number of implantations and weight of the foetuses. (author)

  8. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fox, C. D.; Kron, T.; Leahy, M.; Duchesne, G.; Williams, S.; Tai, K. H.; Haworth, A.; Herschtal, A.; Foroudi, F. [Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Nursing Service, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Department of Radiation Oncology, Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Victoria 3002 (Australia); Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Insititute of Technology, Melbourne, Victoria 3000 (Australia); Department of Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Department of Radiation Oncology, Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Victoria 3010 (Australia)

    2011-11-15

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

  9. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Fox, C. D.; Kron, T.; Leahy, M.; Duchesne, G.; Williams, S.; Tai, K. H.; Haworth, A.; Herschtal, A.; Foroudi, F.

    2011-01-01

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

  10. Micro-morphologic changes around biophysically-stimulated titanium implants in ovariectomized rats

    Directory of Open Access Journals (Sweden)

    Chang Ting-Ling

    2007-07-01

    Full Text Available Abstract Background Osteoporosis may present a risk factor in achievement of osseointegration because of its impact on bone remodeling properties of skeletal phsiology. The purpose of this study was to evaluate micro-morphological changes in bone around titanium implants exposed to mechanical and electrical-energy in osteoporotic rats. Methods Fifteen 12-week old sprague-dowley rats were ovariectomized to develop osteoporosis. After 8 weeks of healing period, two titanium implants were bilaterally placed in the proximal metaphyses of tibia. The animals were randomly divided into a control group and biophysically-stimulated two test groups with five animals in each group. In the first test group, a pulsed electromagnetic field (PEMF stimulation was administrated at a 0.2 mT 4 h/day, whereas the second group received low-magnitude high-frequency mechanical vibration (MECHVIB at 50 Hz 14 min/day. Following completion of two week treatment period, all animals were sacrificed. Bone sites including implants were sectioned, removed en bloc and analyzed using a microCT unit. Relative bone volume and bone micro-structural parameters were evaluated for 144 μm wide peri-implant volume of interest (VOI. Results Mean relative bone volume in the peri-implant VOI around implants PEMF and MECHVIB was significantly higher than of those in control (P P > .05 while the difference in trabecular-number among test and control groups was significant in all VOIs (P Conclusion Biophysical stimulation remarkably enhances bone volume around titanium implants placed in osteoporotic rats. Low-magnitude high-frequency MECHVIB is more effective than PEMF on bone healing in terms of relative bone volume.

  11. High-dose ion implantation of ceramics: benefits and limitations for tribology

    International Nuclear Information System (INIS)

    Bull, S.J.; Page, T.F.

    1988-01-01

    This paper is concerned with the effects of ion implantation on sapphire and soda-lime-silica glass. It establishes the complex interplay between radiation damage, hardness, surface stress and, for the first time, friction. For sapphire, both the shallow indentation hardness response and the integrated near-surface stress increase with damage and exhibit maxima as the surface eventually amorphizes. For the glass, initial damage is shown to result in structural softening before rehardening at higher doses; the radiation-induced stress is a complex function of dose and seems partly linked to electronic rather than displacement processes. Some structural change also eventually occurs akin to amorphization in crystals and is accompanied by changes in hardness and surface stress. Superimposed on these patterns of behaviour are changes in the friction behaviour, part of which is ascribed to increased adhesion presumed due to implantation changing the surface affinity for water adsorption. These effects are demonstrated and discussed in the context of ion-implanted ceramics finding application as controlled friction and/or wear components in engineering applications. Other effects such as gas bubble formation, crazing and sputtering are shown to lead to surface microstructures which can also play a deleterious role in tribological behaviour. (author)

  12. ESR studies of high-energy phosphorus-ion implanted synthetic diamond crystals

    Energy Technology Data Exchange (ETDEWEB)

    Isoya, J [University of Library and Information Science, Tsukuba, Ibaraki (Japan); Kanda, H; Morita, Y; Ohshima, T

    1997-03-01

    Phosphorus is among potential n-type dopants in diamond. High pressure synthetic diamond crystals of type IIa implanted with high energy (9-18 MeV) phosphorus ions have been studied by using electron spin resonance (ESR) technique. The intensity and the linewidth of the ESR signal attributed to the dangling bond of the amorphous phase varied with the implantation dose, suggesting the nature of the amorphization varies with the dose. The ESR signals of point defects have been observed in the low dose as-implanted crystals and in the high dose crystals annealed at high temperature and at high pressure. (author)

  13. Characterization of High Dose Mn, Fe, and Ni implantation into p-GaN

    CERN Document Server

    Pearton, S J; Thaler, G; Abernathy, C R; Theodoropoulou, N; Hebard, A F; Chu, S N G; Wilson, R G; Zavada, J M; Polyakov, A Y; Osinsky, A V; Norris, P E; Chow, P P; Wowchack, A M; Hove, J M V; Park, Y D

    2002-01-01

    The magnetization of p-GaN or p-AlGaN/GaN superlattices was measured after implantation with high doses (3-5x10 sup 1 sup 6 cm sup - sup 2) of Mn, Fe, or Ni and subsequent annealing at 700-1000 deg. C. The samples showed ferromagnetic contributions below temperatures ranging from 190-250 K for Mn to 45-185 K for Ni and 80-250 K for Fe. The use of superlattices to enhance the hole concentration did not produce any change in ferromagnetic ordering temperature. No secondary phase formation was observed by x-ray diffraction, transmission electron microscopy, or selected area diffraction pattern analysis for the doses we employed.

  14. Features of aseptic granulomatous imflammation in rats subjected to the chronic action of gamma irradiation in small doses

    Energy Technology Data Exchange (ETDEWEB)

    Goranov, I; Krushkov, I; Statelov, V; Bratanov, M; Nacheva, V; Gospodinova, D; Serafimov, A

    1976-04-01

    Wistar rats were given a Co-60 dose of 2 r/day over a period of 8 months, or a total dose of 400 r. Two sterile sponge scraps of the same size and form were introduced subcutaneously into the intracapsular space of rats in the control and irradiated groups. Cuts were made in the subcutaneous tissue near the implanted foreign bodies. A vigorous inflammatory reaction developed in the unirradiated animals. The skin granulated normally. The irradiated animals showed a general bleeding of the tissues at the implantation site. A number of deviations were noted during the tissue granulation of the irradiated rats. The migration of leucocytes into the infected site was decreased. The formation of macrophage elements and their activity was lower in the irradiated animals. The reaction of the connective tissue turned out to be a rather sensitive test of the disruptive effects of long-term irradiation. 11 refs.

  15. Characteristics of MOSFETs fabricated in silicon-on-insulator material formed by high-dose oxygen ion implantation

    International Nuclear Information System (INIS)

    Lam, H.W.; Pinizzotto, R.F.; Yuan, H.T.; Bellavance, D.W.

    1981-01-01

    By implanting a dose of 6 x 10 17 cm -2 of 32 O 2 + at 300 keV into a silicon wafer, a buried oxide layer is formed. Crystallinity of the silicon layer above the buried oxide layer is maintained by applying a high (>200 0 C) substrate temperature during the ion implantation process. A two-step anneal cycle is found to be adequate to form the insulating buried oxide layer and to repair the implantation damage in the silicon layer on top of the buried oxide. A surface electron mobility as high as 710 cm 2 /Vs has been measured in n-channel MOSFETs fabricated in a 0.5 μm-thick epitaxial layer grown on the buried oxide wafer. A minimum subthreshold current of about 10 pA per micron of channel width at Vsub(DS)=2 V has been measured. (author)

  16. Dose measurement of ion implanted silicon by RBS technique

    International Nuclear Information System (INIS)

    Kamawanna, Teerasak; Intarasiri, Saweat; Prapunsri, Chowunchun; Thongleurm, Chome; Maleepatra, Saenee; Singkarat, Somsorn

    2003-10-01

    Surface modification can be achieved by ion implantation. This study used a 1 mm thick silicon wafer as a target which was implanted with Ar+ at 80 keV. The degree of the modification depends on both the ion energy and the implanted dose. The distribution of argon in the silicon substrate and the absolute implanted dose can be measured by using Rutherford Backscattering Spectrometry (RBS). These investigations utilized a 1.7 MV Tandetron accelerator system at Chiang Mai University. The dose determination by a direct calculation is in agreement with the simulation by the SIMNRA code

  17. Time Course of Peri-Implant Bone Regeneration around Loaded and Unloaded Implants in a Rat Model

    Science.gov (United States)

    Jariwala, Shailly H.; Wee, Hwabok; Roush, Evan P.; Whitcomb, Tiffany L.; Murter, Christopher; Kozlansky, Gery; Lakhtakia, Akhlesh; Kunselman, Allen R.; Donahue, Henry J.; Armstrong, April D.; Lewis, Gregory S.

    2018-01-01

    The time-course of cancellous bone regeneration surrounding mechanically loaded implants affects implant fixation, and is relevant to determining optimal rehabilitation protocols following orthopaedic surgeries. We investigated the influence of controlled mechanical loading of titanium-coated polyether-ether ketone (PEEK) implants on osseointegration using time-lapsed, non-invasive, in vivo micro-computed tomography (micro-CT) scans. Implants were inserted into proximal tibial metaphyses of both limbs of eight female Sprague-Dawley rats. External cyclic loading (60 μm or 100 μm displacement, 1 Hz, 60 seconds) was applied every other day for 14 days to one implant in each rat, while implants in contralateral limbs served as the unloaded controls. Hind limbs were imaged with high-resolution micro-CT (12.5 μm voxel size) at 2, 5, 9, and 12 days post-surgery. Trabecular changes over time were detected by 3D image registration allowing for measurements of bone-formation rate (BFR) and bone-resorption rate (BRR). At day 9, mean %BV/TV for loaded and unloaded limbs were 35.5 ± 10.0 % and 37.2 ± 10.0 %, respectively, and demonstrated significant increases in bone volume compared to day 2. BRR increased significantly after day 9. No significant differences between bone volumes, BFR, and BRR were detected due to implant loading. Although not reaching significance (p = 0.16), an average 119 % increase in pull-out strength was measured in the loaded implants. PMID:27381807

  18. Effects of high dose olive leaf extract on haemodynamic and oxidative stress parameters in normotensive and spontaneously hypertensive rats

    Directory of Open Access Journals (Sweden)

    Dekanski Dragana

    2014-01-01

    Full Text Available Antihypertensive activity of natural antioxidant, olive leaf extract (OLE is known, but its influence on cardiovascular system when administered in a high dose has not been investigated yet. Our aim was to determine the acute effects of excessive intake of standardized OLE on blood pressure, heart rate and oxidative status in both spontaneously hypertensive rats and normotensive Wistar rats. Systolic arterial pressure and heart rate were measured using a tail-cuff, pneumatic pulse detector, before, 60 and 120 minutes after intragastric OLE administration. Activities of catalase, glutathione peroxidase, superoxide dismutase (SOD and glutathione reductase in erythrocytes, as well as lipid peroxidation in plasma (pTBARS were measured at the same time points, spectrophotometrically. High-dose OLE did not influence blood pressure, heart rate and pTBARS in normotensive rats, while SOD, catalase, and glutathione reductase activities significantly increased. The same dose significantly decreased blood pressure in hypertensive rats, but increased pTBARS and SOD activity. Excessive oral intake of OLE induced moderate hypotensive effects in spontaneously hypertensive rats only, suggesting absence of harmful haemodynamic effects after oral overdose in both rats strain. However, its prooxidative role when given in high dose in hypertensive organism should not be neglected. [Projekat Ministarstva nauke Republike Srbije, br. 175096

  19. Low dose monitoring by double implant technique in IC fabrication

    International Nuclear Information System (INIS)

    Ahmad, I.B.; Weidemann, J.

    1995-01-01

    The utilisation of low dose implant monitoring (using Boron) in a manufacturing line has been discussed. The utilisation of phosphorus ions as the second implant dose were also studied as comparison. The technique relies on the fact that the sheet resistant of doped layer will increase significantly when damaged by relatively low implant dose. The technique is very sensitive and applicable for adjusting the channel dose so that an accurate threshold voltage in MOS device could be achieved

  20. Metallization of ion beam synthesized Si/3C-SiC/Si layer systems by high-dose implantation of transition metal ions

    International Nuclear Information System (INIS)

    Lindner, J.K.N.; Wenzel, S.; Stritzker, B.

    2001-01-01

    The formation of metal silicide layers contacting an ion beam synthesized buried 3C-SiC layer in silicon by means of high-dose titanium and molybdenum implantations is reported. Two different strategies to form such contact layers are explored. The titanium implantation aims to convert the Si top layer of an epitaxial Si/SiC/Si layer sequence into TiSi 2 , while Mo implantations were performed directly into the SiC layer after selectively etching off all capping layers. Textured and high-temperature stable C54-TiSi 2 layers with small additions of more metal-rich silicides are obtained in the case of the Ti implantations. Mo implantations result in the formation of the high-temperature phase β-MoSi 2 , which also grows textured on the substrate. The formation of cavities in the silicon substrate at the lower SiC/Si interface due to the Si consumption by the growing silicide phase is observed in both cases. It probably constitutes a problem, occurring whenever thin SiC films on silicon have to be contacted by silicide forming metals independent of the deposition technique used. It is shown that this problem can be solved with ion beam synthesized contact layers by proper adjustment of the metal ion dose

  1. Microstructure of buried CoSi2 layers formed by high-dose Co implantation into (100) and (111) Si substrates

    International Nuclear Information System (INIS)

    Bulle-Lieuwma, C.W.T.; Van Ommen, A.H.; Vandenhoudt, D.E.W.; Ottenheim, J.J.M.; de Jong, A.F.

    1991-01-01

    Heteroepitaxial Si/CoSi 2 /Si structures have been synthesized by implanting 170-keV Co + with doses in the range 1--3x10 17 Co + ions/cm 2 into (100) and (111) Si substrates and subsequent annealing. The microstructure of both the as-implanted and annealed structures is investigated in great detail by transmission electron microscopy, high-resolution electron microscopy, and x-ray diffraction. In the as-implanted samples, the Co is present as CoSi 2 precipitates, occurring both in aligned (A-type) and twinned (B-type) orientation. For the highest dose, a continuous layer of stoichiometric CoSi 2 is already formed during implantation. It is found that the formation of a connected layer, already during implantation, is crucial for the formation of a buried CoSi 2 layer upon subsequent annealing. Particular attention is given to the coordination of the interfacial Co atoms at the Si/CoSi 2 (111) interfaces of both types of precipitates. We find that the interfacial Co atoms at the A-type interfaces are fully sevenfold coordinated, whereas at the B-type interfaces they appear to be eightfold coordinated

  2. The use of linear programming in optimization of HDR implant dose distributions

    International Nuclear Information System (INIS)

    Jozsef, Gabor; Streeter, Oscar E.; Astrahan, Melvin A.

    2003-01-01

    The introduction of high dose rate brachytherapy enabled optimization of dose distributions to be used on a routine basis. The objective of optimization is to homogenize the dose distribution within the implant while simultaneously satisfying dose constraints on certain points. This is accomplished by varying the time the source dwells at different locations. As the dose at any point is a linear function of the dwell times, a linear programming approach seems to be a natural choice. The dose constraints are inherently linear inequalities. Homogeneity requirements are linearized by minimizing the maximum deviation of the doses at points inside the implant from a prescribed dose. The revised simplex method was applied for the solution of this linear programming problem. In the homogenization process the possible source locations were chosen as optimization points. To avoid the problem of the singular value of the dose at a source location from the source itself we define the 'self-contribution' as the dose at a small distance from the source. The effect of varying this distance is discussed. Test cases were optimized for planar, biplanar and cylindrical implants. A semi-irregular, fan-like implant with diverging needles was also investigated. Mean central dose calculation based on 3D Delaunay-triangulation of the source locations was used to evaluate the dose distributions. The optimization method resulted in homogeneous distributions (for brachytherapy). Additional dose constraints--when applied--were satisfied. The method is flexible enough to include other linear constraints such as the inclusion of the centroids of the Delaunay-triangulation for homogenization, or limiting the maximum allowable dwell time

  3. Antidiabetic Effect of Fresh Nopal (Opuntia ficus-indica in Low-Dose Streptozotocin-Induced Diabetic Rats Fed a High-Fat Diet

    Directory of Open Access Journals (Sweden)

    Seung Hwan Hwang

    2017-01-01

    Full Text Available The objective of the present study was to evaluate α-glucosidase inhibitory and antidiabetic effects of Nopal water extract (NPWE and Nopal dry power (NADP in low-dose streptozotocin- (STZ- induced diabetic rats fed a high-fat diet (HFD. The type 2 diabetic rat model was induced by HFD and low-dose STZ. The rats were divided into four groups as follows: (1 nondiabetic rats fed a regular diet (RD-Control; (2 low-dose STZ-induced diabetic rats fed HFD (HF-STZ-Control; (3 low-dose STZ-induced diabetic rats fed HFD and supplemented with NPWE (100 mg/kg body weight, HF-STZ-NPWE; and (4 low-dose STZ-induced diabetic rats fed HFD and supplemented with comparison medication (rosiglitazone, 10 mg/kg, body weight, HF-STZ-Rosiglitazone. In results, NPWE and NADP had IC50 values of 67.33 and 86.68 μg/mL, both of which exhibit inhibitory activities but lower than that of acarbose (38.05 μg/mL while NPWE group significantly decreased blood glucose levels compared to control and NPDP group on glucose tolerance in the high-fat diet fed rats model (P<0.05. Also, the blood glucose levels of HR-STZ-NPWE group were significantly lower (P<0.05 than HR-STZ-Control group on low-dose STZ-induced diabetic rats fed HFD. Based on these findings, we suggested that NPWE could be considered for the prevention and/or treatment of blood glucose and a potential use as a dietary supplement.

  4. Antidiabetic Effect of Fresh Nopal (Opuntia ficus-indica) in Low-Dose Streptozotocin-Induced Diabetic Rats Fed a High-Fat Diet.

    Science.gov (United States)

    Hwang, Seung Hwan; Kang, Il-Jun; Lim, Soon Sung

    2017-01-01

    The objective of the present study was to evaluate α -glucosidase inhibitory and antidiabetic effects of Nopal water extract (NPWE) and Nopal dry power (NADP) in low-dose streptozotocin- (STZ-) induced diabetic rats fed a high-fat diet (HFD). The type 2 diabetic rat model was induced by HFD and low-dose STZ. The rats were divided into four groups as follows: (1) nondiabetic rats fed a regular diet (RD-Control); (2) low-dose STZ-induced diabetic rats fed HFD (HF-STZ-Control); (3) low-dose STZ-induced diabetic rats fed HFD and supplemented with NPWE (100 mg/kg body weight, HF-STZ-NPWE); and (4) low-dose STZ-induced diabetic rats fed HFD and supplemented with comparison medication (rosiglitazone, 10 mg/kg, body weight, HF-STZ-Rosiglitazone). In results, NPWE and NADP had IC 50 values of 67.33 and 86.68  μ g/mL, both of which exhibit inhibitory activities but lower than that of acarbose (38.05  μ g/mL) while NPWE group significantly decreased blood glucose levels compared to control and NPDP group on glucose tolerance in the high-fat diet fed rats model ( P < 0.05). Also, the blood glucose levels of HR-STZ-NPWE group were significantly lower ( P < 0.05) than HR-STZ-Control group on low-dose STZ-induced diabetic rats fed HFD. Based on these findings, we suggested that NPWE could be considered for the prevention and/or treatment of blood glucose and a potential use as a dietary supplement.

  5. Formation of aluminium nitride and segregation of Cu impurity atoms in aluminium implanted by high dose nitrogen ions

    International Nuclear Information System (INIS)

    Lin Chenglu; Hemment, P.L.F.; Li Jinhua; Zou Shichang

    1994-01-01

    Aluminium films with a thickness of 7000 A (containing 0.85% copper) were deposited on silicon substrates. 400 keV N 2 + or 350 keV N + ions were implanted into the aluminium films or at the interface between the aluminium and silicon, respectively. Automatic spreading resistance (ASR), Fourier transform infrared spectroscopy (FTIR) and Rutherford backscattering (RBS) and channelling were used to characterize the formation of aluminium nitride and the depth distribution of the Cu impurity in the aluminium films after ion implantation and post-annealing. The formation of a stoichiometric AlN layer with high resistance was evident from ASR, RBS analysis and FTIR measurements by the presence of the absorption band at 650 cm -1 . When the implanted nitrogen is near the interface between the aluminium and silicon, a multilayer structure can be obtained, which consists of aluminium, aluminium nitride and the silicon substrate. Cu, which is a background impurity in the deposited aluminium films, segregated into the synthesised aluminium nitride during high dose nitrogen ion implantation. This is due to irradiation-induced segregation during ion implantation. (orig.)

  6. Development of microcontroller based instrumentation for low dose implantation

    International Nuclear Information System (INIS)

    Suresh, K.; Saravanan, K.; Panigrahi, B.K.; Nair, K.G.M.

    2011-01-01

    In experiments like ion implantation based ion track formations, the sample is implanted to low doses of the order of 10 10 ions/cm 2 , limiting the ion beam currents to be less than 1-5 x 10 -12 A. However the standard current integrators available are not sensitive to very low currents, causing an unacceptable high level of error in dose measurement. Hence a low dose implantation measurement system has been developed. It consists of a very sensitive low current preamplifier with full scale input 1nA/100pA, a standard current integrator, a microcontroller based interface circuit, which are connected to a personal computer(PC) through USB. Two types of the software are developed for the system: the microcontroller firmware using C and windows based virtual instrument programs using LabVIEW 7.0. Necessary precautions associated with pA level measurement like rigidly fastened good quality cables, low ripple DC power supply, shielding, close mounting of the preamplifier to the sample are adopted. After necessary calibrations with an ECIL make low current source, the system has been put into regular use. Design and development details, salient features are discussed in this paper. (author)

  7. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Woo; Hong, Se Mie [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of)

    2011-11-15

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  8. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    International Nuclear Information System (INIS)

    Lee, Jeong Woo; Hong, Se Mie

    2011-01-01

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  9. High dose, heavy ion implantation into metals: the use of sacrificial surface layers to enhance retention

    International Nuclear Information System (INIS)

    Clapham, L.

    1994-01-01

    While of considerable interest for the production of metallic alloys, high dose, heavy ion implantation is highly problematical, since the process is limited by sputtering effects. Sputtering is less significant, however, for light target materials, such as C and Al. This paper summarizes studies involving the use of light materials (such as C and Al) which act as slowly sputtering ''sacrificial layers'' when deposited on metallic targets prior to heavy ion implantation. The use of C and Al sacrificial coatings has enabled implanted ion retentions of 100% to be obtained in a number of ion-metal target systems, where the retentions in uncoated samples were as low as 20%. Ion implantation invariably leads to mixing at the sacrificial layer-metal target interface. This mixing may be detrimental in certain systems, so it is useful to be able to minimize or remove this mixed region. To achieve this, a number of techniques have been investigated: (1) removal of the mixed region in the latter stages of the implant; (2) using a barrier layer or chemical effects to minimize mixing at the sacrificial layer-metal interface; (3) choosing a sacrificial layer material which forms a mixed region which has desirable properties. The results of these investigations, for a number of different ion-target systems, are outlined in this paper. (orig.)

  10. Impact of oedema on implant geometry and dosimetry for temporary high dose rate brachytherapy of the prostate

    International Nuclear Information System (INIS)

    Kiffer, J.D.; Schumer, W.A.; Mantle, C.A.; McKenzie, B.J.; Feigen, M.; Quong, G.G.; Waterman, F.M.

    2003-01-01

    The optimal timing of dosimetry for permanent seed prostatic implants remains contentious given the half life of post-implant oedema resolution. The aim of this study was to establish whether prostatic oedematous change over the duration of a temporary high dose rate (HDR) interstitial brachytherapy (BR) boost would result in significant needle displacement, and whether this change in geometry would influence dosimetry. Two CT scans, one for dosimetric purposes on the day of the implant and the second just prior to implant removal, were obtained for four patients receiving transperineal interstitial prostate brachytherapy. The relative changes in cross-sectional dimensions of the implants were calculated by establishing the change in mean radial distance (MRD) of the needle positions from the geometric centre of the implant for each patient's pair of CT studies. The treatment plan, as calculated from the first CT scan, was used in the second set of CT images to allow a comparison of dose distribution. The percentage change in MRD over the duration of the temporary implants ranged from -1.91% to 1.95%. The maximum change in estimated volume was 3.94%. Dosimetric changes were negligible. In the four cases studied, the degree of oedematous change and consequent displacement of flexiguide needle positions was negligible and did not impact on the dosimetry. The rate and direction of oedematous change can be extremely variable but on the basis of the four cases studied and the results of a larger recent study, it might not be necessary to re-image patients for dosimetric purposes over the duration of a fractionated HDR BT boost to the prostate where flexiguide needles are utilized. Nevertheless, further investigation with larger patient numbers is required. Copyright (2003) Blackwell Science Pty Ltd

  11. A microcontroller-based implantable nerve stimulator used for rats.

    Science.gov (United States)

    Sha, Hong; Zheng, Zheng; Wang, Yan; Ren, Chaoshi

    2005-01-01

    A microcontroller-based stimulator that can be flexible programmed after it has been implanted into a rat was studied. Programmability enables implanted stimulators to generate customized, complex protocols for experiments. After implantation, a coded light pulse train that contains information of specific identification will unlock a certain stimulator. If a command that changing the parameters is received, the microcontroller will update its flash memory after it affirms the commands. The whole size of it is only 1.6 cubic centimeters, and it can work for a month. The devices have been successfully used in animal behavior experiments, especially on rats.

  12. Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose

    International Nuclear Information System (INIS)

    Serduc, Raphael; Fonta, Caroline; Renaud, Luc; Bouchet, Audrey; Braeuer-Krisch, Elke; Sarun, Sukhena; Bravin, Alberto; Le Duc, Geraldine; Laissue, Jean A; Spiga, Jenny; Boutonnat, Jean; Siegbahn, Erik Albert; Esteve, Francois

    2009-01-01

    To analyze the effects of the microbeam width (25, 50 and 75 μm) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 μm wide microbeams, all spaced 211 μm on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 μm wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of ∼50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 μm width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 μm or 25 μm widths when used with a 211 μm on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in all groups. The use

  13. Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose

    Energy Technology Data Exchange (ETDEWEB)

    Serduc, Raphael; Fonta, Caroline; Renaud, Luc [Universite de Toulouse, UPS, Centre de Recherche Cerveau et Cognition (France); Bouchet, Audrey; Braeuer-Krisch, Elke; Sarun, Sukhena; Bravin, Alberto; Le Duc, Geraldine [European Synchrotron Radiation Facility, F38043 Grenoble (France); Laissue, Jean A [Institute of Pathology, University of Bern (Switzerland); Spiga, Jenny [Department of Physics, University of Cagliari, s.p. Monserrato-Sestu, Monserrato (Canada) 09042 (Italy); Boutonnat, Jean [TIMC lab, UMR CNRS 5525, Univ Joseph Fourier, CHU, Grenoble (France); Siegbahn, Erik Albert [Department of Medical Physics, Karolinska Universitetssjukhuset, 17176 Stockholm (Sweden); Esteve, Francois [INSERM U836, Equipe 6, Institut des Neurosciences de Grenoble, 38043 Grenoble Cedex (France)], E-mail: raph.serduc@gmail.com

    2009-11-07

    To analyze the effects of the microbeam width (25, 50 and 75 {mu}m) on the survival of 9L gliosarcoma tumor-bearing rats and on toxicity in normal tissues in normal rats after microbeam radiation therapy (MRT), 9L gliosarcomas implanted in rat brains, as well as in normal rat brains, were irradiated in the MRT mode. Three configurations (MRT25, MRT50, MRT75), each using two orthogonally intersecting arrays of either 25, 50 or 75 {mu}m wide microbeams, all spaced 211 {mu}m on center, were tested. For each configuration, peak entrance doses of 860, 480 and 320 Gy, respectively, were calculated to produce an identical valley dose of 18 Gy per individual array at the center of the tumor. Two, 7 and 14 days after radiation treatment, 42 rats were killed to evaluate histopathologically the extent of tumor necrosis, and the presence of proliferating tumors cells and tumor vessels. The median survival times of the normal rats were 4.5, 68 and 48 days for MRT25, 50 and 75, respectively. The combination of the highest entrance doses (860 Gy per array) with 25 {mu}m wide beams (MRT25) resulted in a cumulative valley dose of 36 Gy and was excessively toxic, as it led to early death of all normal rats and of {approx}50% of tumor-bearing rats. The short survival times, particularly of rats in the MRT25 group, restricted adequate observance of the therapeutic effect of the method on tumor-bearing rats. However, microbeams of 50 {mu}m width led to the best median survival time after 9L gliosarcoma MRT treatment and appeared as the better compromise between tumor control and normal brain toxicity compared with 75 {mu}m or 25 {mu}m widths when used with a 211 {mu}m on-center distance. Despite very high radiation doses, the tumors were not sterilized; viable proliferating tumor cells remained present at the tumor margin. This study shows that microbeam width and peak entrance doses strongly influence tumor responses and normal brain toxicity, even if valley doses are kept constant in

  14. Photon beam dose distributions for patients with implanted temporary tissue expanders

    Science.gov (United States)

    Asena, A.; Kairn, T.; Crowe, S. B.; Trapp, J. V.

    2015-01-01

    This study examines the effects of temporary tissue expanders (TTEs) on the dose distributions of photon beams in breast cancer radiotherapy treatments. EBT2 radiochromic film and ion chamber measurements were taken to quantify the attenuation and backscatter effects of the inhomogeneity. Results illustrate that the internal magnetic port present in a tissue expander causes a dose reduction of approximately 25% in photon tangent fields immediately downstream of the implant. It was also shown that the silicone elastomer shell of the tissue expander reduced the dose to the target volume by as much as 8%. This work demonstrates the importance for an accurately modelled high-density implant in the treatment planning system for post-mastectomy breast cancer patients.

  15. Combination therapy with 1,3-bis(2-chloroethyl)-1-nitrosourea and low dose rate radiation in the 9L rat brain tumor and spheroid models: implications for brain tumor brachytherapy

    International Nuclear Information System (INIS)

    Gutin, P.H.; Bernstein, M.; Sano, Y.; Deen, D.F.

    1984-01-01

    The effects of combination treatment with 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) and low dose rate radiation were studied in the 9L rat brain tumor in vivo model and the 9L multicellular tumor spheroid model. F-344 rats bearing intracerebral 9L gliosarcomas were implanted with removable 125 I sources. Minimal (peripheral) tumor doses of 6387 rad produced an increased life-span (ILS) of 28% over that of control rats implanted with dummy sources, BCNU alone (13.3 mg/kg) produced in an ILS of 67%, and combination treatment with BCNU and implanted 125 I sources produced an ILS of 167%. As measured by a colony-forming efficiency assay, the greatest cell kill in 9L spheroids occurred when BCNU was administered 24 hours before irradiation from a 137 Cs source at a low dose rate of 5 rad/minute. At a higher dose rate of 210 rad/minute, the time dependence of the effects of combination treatment was identical and therefore independent of dose rate

  16. Experimental rat lung tumor model with intrabronchial tumor cell implantation.

    Science.gov (United States)

    Gomes Neto, Antero; Simão, Antônio Felipe Leite; Miranda, Samuel de Paula; Mourão, Lívia Talita Cajaseiras; Bezerra, Nilfácio Prado; Almeida, Paulo Roberto Carvalho de; Ribeiro, Ronaldo de Albuquerque

    2008-01-01

    The objective of this study was to develop a rat lung tumor model for anticancer drug testing. Sixty-two female Wistar rats weighing 208 +/- 20 g were anesthetized intraperitoneally with 2.5% tribromoethanol (1 ml/100 g live weight), tracheotomized and intubated with an ultrafine catheter for inoculation with Walker's tumor cells. In the first step of the experiment, a technique was established for intrabronchial implantation of 10(5) to 5 x 10(5) tumor cells, and the tumor take rate was determined. The second stage consisted of determining tumor volume, correlating findings from high-resolution computed tomography (HRCT) with findings from necropsia and determining time of survival. The tumor take rate was 94.7% for implants with 4 x 10(5) tumor cells, HRCT and necropsia findings matched closely (r=0.953; p<0.0001), the median time of survival was 11 days, and surgical mortality was 4.8%. The present rat lung tumor model was shown to be feasible: the take rate was high, surgical mortality was negligible and the procedure was simple to perform and easily reproduced. HRCT was found to be a highly accurate tool for tumor diagnosis, localization and measurement and may be recommended for monitoring tumor growth in this model.

  17. Chlorhexidine-releasing implant coating on intramedullary nail reduces infection in a rat model

    Directory of Open Access Journals (Sweden)

    SM Shiels

    2018-03-01

    Full Text Available The use of internal intramedullary nails for long bone fracture fixation is a common practice among surgeons. Bacteria naturally attach to these devices, increasing the risk for wound infection, which can result in non- or malunion, additional surgical procedures and extended hospital stays. Intramedullary nail surface properties can be modified to reduce bacterial colonisation and potentially infectious complications. In the current study, a coating combining a non-fouling property with leaching chlorhexidine for orthopaedic implantation was tested. Coating stability and chlorhexidine release were evaluated in vitro. Using a rat model of intramedullary fixation and infection, the effect of the coating on microbial colonisation and fracture healing was evaluated in vivo by quantitative microbiology, micro-computed tomography, plain radiography, three-point bending and/or histology. Low dose systemic cefazolin was administered to increase the similarities to clinical practice, without overshadowing the effect of the anti-infective coating. When introduced into a contaminated wound, the non-fouling chlorhexidine-coated implant reduced the overall bacteria colonisation within the bone and on the implant, reduced the osteolysis and increased the radiographic union, confirming its potential for reducing complications in wounds at high risk of infection. However, when implanted into a sterile wound, non-union increased. Further studies are required to best optimise the anti-microbial effectiveness, while not sacrificing fracture union.

  18. High-grade Angiosarcoma Associated with Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Nicolas R. Smoll, MBBS

    2013-04-01

    Full Text Available Summary: Since the serendipitous discovery that implanted polymers cause sarcomas in rats, much research has been conducted to prove or disprove a link between silicone breast implants and/or polymer-based materials and breast cancer. In light of an initial report that 35% of rats implanted with a variety of polymers developed fibrosarcomas, we report a case of primary angiosarcoma found in a patient presenting with bilateral rupture of gel-filled breast implants.

  19. 'Mgogoro' wa Ushairi wa Kiswahili bado Upo?: Uchunguzi wa ...

    African Journals Online (AJOL)

    Nyimbo za muziki wa Hip hop na Bongo fleva zimekuwa maarufu nchini Tanzania kuanzia miaka ya 1980. Nyimbo hizi, kama mojawapo ya tanzu au kipera cha ushairi simulizi wa Kiswahili, zimekuwa ni chanzo kizuri cha utafiti kuhusiana na masuala mbalimbali yahusikayo. Miongoni mwa mambo yanayoonekana kuanza ...

  20. High energy ion implantation for IC processing

    International Nuclear Information System (INIS)

    Oosterhoff, S.

    1986-01-01

    In this thesis the results of fundamental research on high energy ion implantation in silicon are presented and discussed. The implantations have been carried out with the 500 kV HVEE ion implantation machine, that was acquired in 1981 by the IC technology and Electronics group at Twente University of Technology. The damage and anneal behaviour of 1 MeV boron implantations to a dose of 10 13 /cm 2 have been investigated as a function of anneal temperature by sheet resistance, Hall and noise measurements. (Auth.)

  1. Renal dysfunction induced by long-term exposure to depleted uranium in rats

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Guoying; Xiang, Xiqiao; Chen, Xiao; Wang, Lihua; Hu, Heping; Weng, Shifang [Fudan University, Institute of Radiation Medicine, Shanghai (China)

    2009-01-15

    Depleted uranium (DU) is a kind of radioactive heavy metal which can enter into the body via inhalation (aerosols), ingestion (drinking and eating) and wounds (embedded), and causes chemical and/or radiation-induced toxicities. In this study, male Sprague Dawley rats were surgically implanted in gastrocnemius muscle with DU fragments at three dose levels (low-dose, medium-dose and high-dose), with biologically inert tantalum (Ta) fragments served as controls. At 1 day, 7 days, and 3, 6, and 12 months after implantation, the rats were euthanized and tissue samples were collected, and uranium levels were measured in a variety of tissues by inductively coupled plasma-mass spectrometry (ICP-MS) to analyze the dynamic changes and distribution of uranium in rats. Thereafter, at 3, 6 and 12 months after implantation, the rats were euthanized after the collection of 24 h urine, blood and kidney samples were collected for analysis of DU-induced renal histopathologic changes and renal dysfunction. It was observed that DU concentrations in all the DU implanted groups were higher than that in Ta control group, and DU concentrations in the kidney increased with the implanted times, peaked at the 90 days after implantation, with a high correlation to the implanted DU doses, and then began to decrease gradually and slowly, and the DU concentrations in kidney still maintained at a relatively high level even at the 360 days after implantation. Otherwise, chronic DU contamination could induce the pathological changes of renal glomeruli, tubules and mesenchyme, such as interstitial fibrosis, enlarged interstice of renal tubular epithelial cells, tumefactions and necrosis of epithelial cells, shrinkage and disappearance of cavity of Bowman's capsule. By TEM, it was shown that the basement membrane of glomerulus was incrassated, mitochondrial of kidney proximal tubule had visible tumefaction and became bigger, and the mitochondrial cristae became shorter and disorderly in

  2. Renal dysfunction induced by long-term exposure to depleted uranium in rats

    International Nuclear Information System (INIS)

    Zhu, Guoying; Xiang, Xiqiao; Chen, Xiao; Wang, Lihua; Hu, Heping; Weng, Shifang

    2009-01-01

    Depleted uranium (DU) is a kind of radioactive heavy metal which can enter into the body via inhalation (aerosols), ingestion (drinking and eating) and wounds (embedded), and causes chemical and/or radiation-induced toxicities. In this study, male Sprague Dawley rats were surgically implanted in gastrocnemius muscle with DU fragments at three dose levels (low-dose, medium-dose and high-dose), with biologically inert tantalum (Ta) fragments served as controls. At 1 day, 7 days, and 3, 6, and 12 months after implantation, the rats were euthanized and tissue samples were collected, and uranium levels were measured in a variety of tissues by inductively coupled plasma-mass spectrometry (ICP-MS) to analyze the dynamic changes and distribution of uranium in rats. Thereafter, at 3, 6 and 12 months after implantation, the rats were euthanized after the collection of 24 h urine, blood and kidney samples were collected for analysis of DU-induced renal histopathologic changes and renal dysfunction. It was observed that DU concentrations in all the DU implanted groups were higher than that in Ta control group, and DU concentrations in the kidney increased with the implanted times, peaked at the 90 days after implantation, with a high correlation to the implanted DU doses, and then began to decrease gradually and slowly, and the DU concentrations in kidney still maintained at a relatively high level even at the 360 days after implantation. Otherwise, chronic DU contamination could induce the pathological changes of renal glomeruli, tubules and mesenchyme, such as interstitial fibrosis, enlarged interstice of renal tubular epithelial cells, tumefactions and necrosis of epithelial cells, shrinkage and disappearance of cavity of Bowman's capsule. By TEM, it was shown that the basement membrane of glomerulus was incrassated, mitochondrial of kidney proximal tubule had visible tumefaction and became bigger, and the mitochondrial cristae became shorter and disorderly in alignment

  3. Effect of high doses of L-ascorbic acid on the antioxidative/oxidative state in the rats

    DEFF Research Database (Denmark)

    Niemiec, T.; Sawosz, E.; Chwalibog, André

    2005-01-01

    The objective of this study was to determine the effects of mega-doses of vitamin C (0.3, 0.6 and 0.9% of diet) as a dietary supplement for rats on selected indices of the antioxidative/oxidative state in 40 growing Wistar rats (4x10). It was found that L-ascorbic acid and Total Antioxidative State...... (TAS) in plasma did not increase with increasing vitamin C supply. The results indicate that high doses of L-ascorbic acid (0.3 and 0.9 but not 0.6%) increased the concentration of this antioxidant in plasma. Supplementation of vitamin C above 0.3% to the diets had pro-oxidative effects on lipid...... structures, while application of 0.9% promoted oxidative degradation of rat livers....

  4. Sensitivity and proportionality assessment of metabolites from microdose to high dose in rats using LC-MS/MS.

    Science.gov (United States)

    Ni, Jinsong; Ouyang, Hui; Seto, Carmai; Sakuma, Takeo; Ellis, Robert; Rowe, Josh; Acheampong, Andrew; Welty, Devin; Szekely-Klepser, Gabriella

    2010-03-01

    The objective of this study was to evaluate the sensitivity requirement for LC-MS/MS as an analytical tool to characterize metabolites in plasma and urine at microdoses in rats and to investigate proportionality of metabolite exposure from a microdose of 1.67 µg/kg to a high dose of 5000 µg/kg for atorvastatin, ofloxacin, omeprazole and tamoxifen. Only the glucuronide metabolite of ofloxacin, the hydroxylation metabolite of omeprazole and the hydration metabolite of tamoxifen were characterized in rat plasma at microdose by LC-MS/MS. The exposure of detected metabolites of omeprazole and tamoxifen appeared to increase in a nonproportional manner with increasing doses. Exposure of ortho- and para-hydroxyatorvastatin, but not atorvastatin and lactone, increased proportionally with increasing doses. LC-MS/MS has demonstrated its usefulness for detecting and characterizing the major metabolites in plasma and urine at microdosing levels in rats. The exposure of metabolites at microdose could not simply be used to predict their exposure at higher doses.

  5. Conditioned instrumental behaviour in the rat: Effects of prenatal irradiation with various low dose-rate doses

    International Nuclear Information System (INIS)

    Klug, H.

    1986-01-01

    4 groups of rats of the Wistar-strain were subjected to γ-irradiation on the 16th day of gestation. 5 rats received 0,6 Gy low dose rate irradiation, 5 animals received 0,9 Gy low dose and 6 high dose irradiation, 3 females were shamirradiated. The male offspring of these 3 irradiation groups and 1 control group were tested for locomotor coordination on parallel bars and in a water maze. The female offspring were used in an operant conditioning test. The locomotor test showed slight impairment of locomotor coordination in those animals irradiated with 0,9 Gy high dose rate. Swimming ability was significantly impaired by irradiation with 0,9 Gy high dose rate. Performance in the operant conditioning task was improved by irradiation with 0,9 Gy both low and high dose rate. The 0,9 Gy high dose rate group learned faster than all the other groups. For the dose of 0,9 Gy a significant dose rate effect could be observed. For the dose of 0,6 Gy a similar tendency was observed, differences between 0,6 Gy high and low dose rate and controls not being significant. (orig./MG) [de

  6. High-intensity low energy titanium ion implantation into zirconium alloy

    Science.gov (United States)

    Ryabchikov, A. I.; Kashkarov, E. B.; Pushilina, N. S.; Syrtanov, M. S.; Shevelev, A. E.; Korneva, O. S.; Sutygina, A. N.; Lider, A. M.

    2018-05-01

    This research describes the possibility of ultra-high dose deep titanium ion implantation for surface modification of zirconium alloy Zr-1Nb. The developed method based on repetitively pulsed high intensity low energy titanium ion implantation was used to modify the surface layer. The DC vacuum arc source was used to produce metal plasma. Plasma immersion titanium ions extraction and their ballistic focusing in equipotential space of biased electrode were used to produce high intensity titanium ion beam with the amplitude of 0.5 A at the ion current density 120 and 170 mA/cm2. The solar eclipse effect was used to prevent vacuum arc titanium macroparticles from appearing in the implantation area of Zr sample. Titanium low energy (mean ion energy E = 3 keV) ions were implanted into zirconium alloy with the dose in the range of (5.4-9.56) × 1020 ion/cm2. The effect of ion current density, implantation dose on the phase composition, microstructure and distribution of elements was studied by X-ray diffraction, scanning electron microscopy and glow-discharge optical emission spectroscopy, respectively. The results show the appearance of Zr-Ti intermetallic phases of different stoichiometry after Ti implantation. The intermetallic phases are transformed from both Zr0.7Ti0.3 and Zr0.5Ti0.5 to single Zr0.6Ti0.4 phase with the increase in the implantation dose. The changes in phase composition are attributed to Ti dissolution in zirconium lattice accompanied by the lattice distortions and appearance of macrostrains in intermetallic phases. The depth of Ti penetration into the bulk of Zr increases from 6 to 13 μm with the implantation dose. The hardness and wear resistance of the Ti-implanted zirconium alloy were increased by 1.5 and 1.4 times, respectively. The higher current density (170 mA/cm2) leads to the increase in the grain size and surface roughness negatively affecting the tribological properties of the alloy.

  7. Dose reduction in LDR brachytherapy by implanted prostate gold fiducial markers.

    Science.gov (United States)

    Landry, Guillaume; Reniers, Brigitte; Lutgens, Ludy; Murrer, Lars; Afsharpour, Hossein; de Haas-Kock, Danielle; Visser, Peter; van Gils, Francis; Verhaegen, Frank

    2012-03-01

    The dosimetric impact of gold fiducial markers (FM) implanted prior to external beam radiotherapy of prostate cancer on low dose rate (LDR) brachytherapy seed implants performed in the context of combined therapy was investigated. A virtual water phantom was designed containing a single FM. Single and multi source scenarios were investigated by performing Monte Carlo dose calculations, along with the influence of varying orientation and distance of the FM with respect to the sources. Three prostate cancer patients treated with LDR brachytherapy for a recurrence following external beam radiotherapy with implanted FM were studied as surrogate cases to combined therapy. FM and brachytherapy seeds were identified on post implant CT scans and Monte Carlo dose calculations were performed with and without FM. The dosimetric impact of the FM was evaluated by quantifying the amplitude of dose shadows and the volume of cold spots. D(90) was reported based on the post implant CT prostate contour. Large shadows are observed in the single source-FM scenarios. As expected from geometric considerations, the shadows are dependent on source-FM distance and orientation. Large dose reductions are observed at the distal side of FM, while at the proximal side a dose enhancement is observed. In multisource scenarios, the importance of shadows appears mitigated, although FM at the periphery of the seed distribution caused underdosage (LDR brachytherapy seed implant dose distributions. Therefore, reduced tumor control could be expected from FM implanted in tumors, although our results are too limited to draw conclusions regarding clinical significance.

  8. Complementary study of the internal porous silicon layers formed under high-dose implantation of helium ions

    Energy Technology Data Exchange (ETDEWEB)

    Lomov, A. A., E-mail: lomov@ftian.ru; Myakon’kikh, A. V. [Russian Academy of Sciences, Institute of Physics and Technology (Russian Federation); Chesnokov, Yu. M. [National Research Centre “Kurchatov Institute” (Russian Federation); Shemukhin, A. A.; Oreshko, A. P. [Moscow State University (Russian Federation)

    2017-03-15

    The surface layers of Si(001) substrates subjected to plasma-immersion implantation of helium ions with an energy of 2–5 keV and a dose of 5 × 10{sup 17} cm{sup –2} have been investigated using high-resolution X-ray reflectivity, Rutherford backscattering, and transmission electron microscopy. The electron density depth profile in the surface layer formed by helium ions is obtained, and its elemental and phase compositions are determined. This layer is found to have a complex structure and consist of an upper amorphous sublayer and a layer with a porosity of 30–35% beneath. It is shown that the porous layer has the sharpest boundaries at a lower energy of implantable ions.

  9. Possible sources of neuroprotection following subretinal silicon chip implantation in RCS rats

    Science.gov (United States)

    Pardue, Machelle T.; Phillips, Michael J.; Yin, Hang; Fernandes, Alcides; Cheng, Yian; Chow, Alan Y.; Ball, Sherry L.

    2005-03-01

    Current retinal prosthetics are designed to stimulate existing neural circuits in diseased retinas to create a visual signal. However, implantation of retinal prosthetics may create a neurotrophic environment that also leads to improvements in visual function. Possible sources of increased neuroprotective effects on the retina may arise from electrical activity generated by the prosthetic, mechanical injury due to surgical implantation, and/or presence of a chronic foreign body. This study evaluates these three neuroprotective sources by implanting Royal College of Surgeons (RCS) rats, a model of retinitis pigmentosa, with a subretinal implant at an early stage of photoreceptor degeneration. Treatment groups included rats implanted with active and inactive devices, as well as sham-operated. These groups were compared to unoperated controls. Evaluation of retinal function throughout an 18 week post-implantation period demonstrated transient functional improvements in eyes implanted with an inactive device at 6, 12 and 14 weeks post-implantation. However, the number of photoreceptors located directly over or around the implant or sham incision was significantly increased in eyes implanted with an active or inactive device or sham-operated. These results indicate that in the RCS rat localized neuroprotection of photoreceptors from mechanical injury or a chronic foreign body may provide similar results to subretinal electrical stimulation at the current output evaluated here.

  10. Approaches to reducing photon dose calculation errors near metal implants

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Jessie Y.; Followill, David S.; Howell, Rebecca M.; Mirkovic, Dragan; Kry, Stephen F., E-mail: sfkry@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States); Liu, Xinming [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States); Stingo, Francesco C. [Department of Biostatistics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030 (United States)

    2016-09-15

    Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well as two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact

  11. Approaches to reducing photon dose calculation errors near metal implants

    International Nuclear Information System (INIS)

    Huang, Jessie Y.; Followill, David S.; Howell, Rebecca M.; Mirkovic, Dragan; Kry, Stephen F.; Liu, Xinming; Stingo, Francesco C.

    2016-01-01

    Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well as two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact

  12. Improved Bone Micro Architecture Healing Time after Implant Surgery in an Ovariectomized Rat.

    Science.gov (United States)

    Takahashi, Takahiro; Watanabe, Takehiro; Nakada, Hiroshi; Sato, Hiroki; Tanimoto, Yasuhiro; Sakae, Toshiro; Kimoto, Suguru; Mijares, Dindo; Zhang, Yu; Kawai, Yasuhiko

    2016-01-01

    The present animal study investigated whether oral intake of synthetic bone mineral (SBM) improves peri-implant bone formation and bone micro architecture (BMA). SBM was used as an intervention experimental diet and AIN-93M was used as a control. The SBM was prepared by mixing dicalcium phosphate dihydrate (CaHPO 4 ·2H 2 O) and magnesium and zinc chlorides (MgCl 2 and ZnCl 2 , respectively), and hydrolyzed in double-distilled water containing dissolved potassium carbonate and sodium fluoride. All rats were randomly allocated into one of two groups: a control group was fed without SBM (n = 18) or an experimental group was fed with SBM (n = 18), at seven weeks old. At 9 weeks old, all rats underwent implant surgery on their femurs under general anesthesia. The implant was inserted into the insertion socket prepared at rats' femur to a depth of 2.5 mm by using a drill at 500 rpm. Nine rats in each group were randomly selected and euthanized at 2 weeks after implantation. The remaining nine rats in each group continued their diets, and were euthanized in the same manner at 4 weeks after implantation. The femur, including the implant, was removed from the body and implant was pulled out by an Instron universal testing machine. After the implant removal, BMA was evaluated by bone surface ratio (BS/BV), bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular number (TbN), trabecular star volume (Vtr), and micro-CT images. BS/BV, BV/TV, TbTh and Vtr were significantly greater in the rats were fed with SBM than those were fed without SBM at 2 and 4 weeks after implantation (P implant formation and BMA, prominent with trabecular bone structure. The effect of SBM to improve secondary stability of the implant, and shortening the treatment period should be investigated in the future study.

  13. Titanium diffusion in shinbone of rats with osseointegrated implants.

    Science.gov (United States)

    Grenón, Miriam S; Robledo, José; Ibáñez, Juan Carlos; Sánchez, Héctor J

    2016-11-01

    Dental implants are composed of commercially pure Ti (which is actually an alloy of titanium, and minor or trace components such as aluminium and vanadium). When the implant is inserted, its surface undergoes a number of chemical and mechanical processes, releasing particles of titanium to the medium. The metabolism of free ions of titanium is uncertain; the uptaking processes in the body are not well known, nor their toxic dose. In addition, physical properties of newly formed bone, such as diffusivity and activation energy, are scarce and rarely studied. In this study, we analysed the diffusion of titanium in the titanium-implanted shinbones of six adult male Wistar rats by spatially resolved micro x-ray fluorescence. The measurements were carried out at the microfluorescence station of the x-ray fluorescence (XRF) beamline of the Brazilian synchrotron facility LNLS (from Portuguese 'Laboratorio Nacional de Luz Sincrotron'). For each sample, XRF spectra were taken by linear scanning in area near the new bone formed around the Ti implant. The scanning line shows a clear effect of titanium diffusion whereas calcium intensity presents a different behaviour. Moreover, a clear correlation among the different structures of bones is observed in the Ti and Ca intensities. The results obtained in these measurements may allow determining quantitatively the parameters of diffusion rates and other physical properties of new bone like diffusion coefficients. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  14. Determination of metallic traces in kidneys, livers, lungs and spleens of rats with metallic implants after a long implantation time.

    Science.gov (United States)

    Rubio, Juan Carlos; Garcia-Alonso, Maria Cristina; Alonso, Concepcion; Alobera, Miguel Angel; Clemente, Celia; Munuera, Luis; Escudero, Maria Lorenza

    2008-01-01

    Metallic transfer from implants does not stop at surrounding tissues, and metallic elements may be transferred by proteins to become lodged in organs far from the implant. This work presents an in vivo study of metallic implant corrosion to measure metallic element accumulation in organs located far from the implant, such as kidneys, livers, lungs and spleens. The studied metallic implant materials were CoCr alloy, Ti, and the experimental alloy MA956 coated with alpha-alumina. The implants were inserted in the hind legs of Wistar rats. Analysis for Co, Cr, Ti and Al metallic traces was performed after a long exposure time of 12 months by Inductively Coupled Plasma (ICP) with Mass Spectrometry (MS). According to the results, the highest Cr and Ti concentrations were detected in spleens. Co is mainly found in kidneys, since this element is eliminated via urine. Cr and Ti traces increased significantly in rat organs after the long implantation time. The organs of rats implanted with the alpha-alumina coated experimental MA956 did not present any variation in Al content after 12 months, which means there was no degradation of the alumina layer surface.

  15. Effects of dose, species, and dosing vehicle on the disposition of methacrylonitrile (MAN) in male rats

    International Nuclear Information System (INIS)

    Sanchez, I.M.; Ghanayem, B.I.

    1991-01-01

    MAN is structurally similar to known carcinogen acrylontrile (AN), with nitriles having similar industrial uses. Current studies were designed to investigate the biological fate of 2- 14 C-MAN in rats. After gavage administration of 115, 11.5 or 1.15 mg MAN/kg in water, F344 male rats were placed in glass metabolism cages and urine, expired air and feces were collected. Rats were sacrificed at various times and concentration of MAN-derived radioactivity in tissues was determined. MAN was rapidly absorbed from the GI tract and distributed to all major tissues. Sixty-70% of the low and medium doses were exhaled as 14 CO 2 in 72 hr compared to 25% of the highest dose. While 40% of the highest dose was expired as organic volatiles in 72 hr, only 9-12% of the low and accounted for 20-30% of all doses within 72 hr after dosing. Comparison of MAN disposition in Sprague-Dawley (SD) and F344 rats at 115 mg/kg revealed that SD rats excreted a greater % of the dose as 14 CO 2 and in the urine than did F344 rats. Administration of 115 mg MAN/kg to SD male rats in safflower oil resulted in increased elimination of MAN-derived radioactivity as CO 2 , volatiles, and in the urine over that observed when administered in water. These results suggest that: (1) saturation of MAN metabolism occurs at high doses: (2) MAN metabolism and disposition differ with the strain of rats studied; (3) MAN disposition may vary with the dosing vehicle used; and (4) MAN metabolism and disposition is apparently different from that reported on AN

  16. Curcumin Implants, not Curcumin Diet Inhibits Estrogen-Induced Mammary Carcinogenesis in ACI Rats

    Science.gov (United States)

    Bansal, Shyam S.; kausar, Hina; Vadhanam, Manicka V.; Ravoori, Srivani; Pan, Jianmin; Rai, Shesh N.; Gupta, Ramesh C.

    2014-01-01

    Curcumin is widely known for its anti-oxidant, anti-inflammatory and anti-proliferative activities in cell culture studies. However, poor oral bioavailability limited its efficacy in animal and clinical studies. Recently, we developed polymeric curcumin implants that circumvents oral bioavailability issues, and tested their potential against 17β-estradiol (E2)-mediated mammary tumorigenesis. Female ACI rats were administered curcumin either via diet (1,000 ppm) or via polymeric curcumin implants (two 2-cm; 200 mg each; 20% drug load) 4 days prior to grafting a subcutaneous E2 silastic implant (1.2 cm, 9 mg E2). Implants were changed after 4½ months to provide higher curcumin dose at the appearance of palpable tumors. The animals were euthanized after 3 weeks, 3 months and after the tumor incidence reached >80% (~6 months) in control animals. The curcumin administered via implants resulted in significant reduction in both the tumor multiplicity (2±1 vs 5±3; p=0.001) and tumor volume (184±198 mm3 vs 280±141 mm3; p=0.0283); the dietary curcumin, however, was ineffective. Dietary curcumin increased hepatic CYP1A and CYP1B1 activities without any effect on CYP3A4 activity whereas curcumin implants increased both CYP1A and CYP3A4 activities but decreased CYP1B1 activity in presence of E2. Since CYP1A and 3A4 metabolize most of the E2 to its non-carcinogenic 2-OH metabolite and CYP1B1 produces potentially carcinogenic 4-OH metabolite, favorable modulation of these CYPs via systemically delivered curcumin could be one of the potential mechanisms. The analysis of plasma and liver by HPLC showed substantially higher curcumin levels via implants versus the dietary route despite substantially higher dose administered. PMID:24501322

  17. ulinganishi wa muundo wa vitomeo katika kamusi mbili za kiswahili

    African Journals Online (AJOL)

    ULINGANISHI WA MUUNDO WA VITOMEO KATIKA KAMUSI MBILI ZA KISWAHILI - KIINGEREZA. E.K.F Chiduo. Abstract. Ulinganishi wa Kamusi Sanifu ya Kiswahili-Kiingereza (KSKK, 1993) na Kamusi ya Kiswahili- Kiingereza (KKK, TUKI 2001) unazingatia mtazamo wa Nkweti-Azel. Mtizamo huu unazingatia vipengelele ...

  18. High energy P implants in silicon

    International Nuclear Information System (INIS)

    Raineri, V.; Cacciato, A.; Benyaich, F.; Priolo, F.; Rimini, E.; Galvagno, G.; Capizzi, S.

    1992-01-01

    Phosphorus ions in the energy range 0.25-1 MeV and in the dose range 2x10 13 -1x10 15 P/cm 2 were implanted into (100) Si single crystal at different tilt angles. In particular channeling and random conditions were investigated. For comparison some implants were performed on samples with a 2 μm thick surface amorphous layer. Chemical concentration P profiles were obtained by secondary ion mass spectrometry. Carrier concentration and mobility profile measurements were carried out by sheet resistance and Hall measurements on implanted van der Pauw patterns. Carrier concentration profiles were also obtained by spreading resistance (SR) measurements. The damage in the as-implanted samples was determined by backscattering and channeling spectrometry (RBS) as a function of the dose and implantation energy. Comparison of random implants in crystal with implants in amorphous layers shows that in the first case it is impossible to completely avoid the channeling tail. In the implants performed under channeling conditions at low doses the P profiles are flat over more than 2 μm thick layers. Furthermore, by increasing the implanted dose, the shape of the profiles dramatically changes due to the dechanneling caused by the crystal disorder. The data are discussed and compared with Monte Carlo simulations using the MARLOWE code. A simple description of the electronic energy loss provides an excellent agreement between the calculated and experimental profiles. (orig.)

  19. Neutron activation analysis for calibration of phosphorus implantation dose

    International Nuclear Information System (INIS)

    Paul, Rick L.; Simons, David S.

    2001-01-01

    A feasibility study was undertaken to determine if radiochemical neutron activation analysis (RNAA) can be used to certify the retained dose of phosphorus implanted in silicon, with the goal of producing a phosphorus SRM. Six pieces of silicon, implanted with a nominal phosphorus dose of 8.5x10 14 atoms·cm -2 were irradiated at a neutron flux of 1.05x10 14 cm -2 ·s -1 . The samples were mixed with carrier, dissolved in acid, the phosphorus isolated by chemical separation, and 32 P measured using a beta proportional counter. A mean phosphorus concentration of (8.35±0.20)x10 14 atoms·cm -2 (uncertainty=1 standard deviation) was determined for the six samples, in agreement with the nominal implanted dose

  20. Brachytherapy optimization using radiobiological-based planning for high dose rate and permanent implants for prostate cancer treatment

    Science.gov (United States)

    Seeley, Kaelyn; Cunha, J. Adam; Hong, Tae Min

    2017-01-01

    We discuss an improvement in brachytherapy--a prostate cancer treatment method that directly places radioactive seeds inside target cancerous regions--by optimizing the current standard for delivering dose. Currently, the seeds' spatiotemporal placement is determined by optimizing the dose based on a set of physical, user-defined constraints. One particular approach is the ``inverse planning'' algorithms that allow for tightly fit isodose lines around the target volumes in order to reduce dose to the patient's organs at risk. However, these dose distributions are typically computed assuming the same biological response to radiation for different types of tissues. In our work, we consider radiobiological parameters to account for the differences in the individual sensitivities and responses to radiation for tissues surrounding the target. Among the benefits are a more accurate toxicity rate and more coverage to target regions for planning high-dose-rate treatments as well as permanent implants.

  1. Evaluation of dose-volume histograms after prostate seed implantation. 4-year experience

    International Nuclear Information System (INIS)

    Hoinkis, C.; Lehmann, D.; Winkler, C.; Herrmann, T.; Hakenberg, O.W.; Wirth, M.P.

    2004-01-01

    Background and purpose: permanent interstitial brachytherapy by seed implantation is a treatment alternative for low-volume low-risk prostate cancer and a complex interdisciplinary treatment with a learning curve. Dose-volume histograms are used to assess postimplant quality. The authors evaluated their learning curve based on dose-volume histograms and analyzed factors influencing implantation quality. Patients and methods: since 1999, 38 patients with a minimum follow-up of 6 months were treated at the authors' institution with seed implantation using palladium-103 or iodine-125, initially using the preplan method and later real-time planning. Postimplant CT was performed after 4 weeks. The dose-volume indices D90, V100, V150, the D max of pre- and postplans, and the size and position of the volume receiving the prescribed dose (high-dose volume) of the postplans were evaluated. In six patients, postplan imaging both by CT and MRI was used and prostate volumes were compared with preimplant transrectal ultrasound volumes. The first five patients were treated under external supervision. Results: patients were divided into three consecutive groups for analysis of the learning curve (group 1: n = 5 patients treated under external supervision; group 2: n = 13 patients; group 3: n = 20 patients). D90 post for the three groups were 79.3%, 74.2%, and 99.9%, the V100 post were 78.6%, 73.5%, and 88.2%, respectively. The relationship between high-dose volume and prostate volume showed a similar increase as the D90, while the relationship between high-dose volume lying outside the prostate and prostate volume remained constant. The ratio between prostate volumes from transrectal ultrasound and CT imaging decreased with increasing D90 post , while the preplanning D90 and V100 remained constant. The different isotopes used, the method of planning, and the implanted activity per prostate volume did not influence results. Conclusion: a learning curve characterized by an increase

  2. Assessment of implantable infusion pumps for continuous infusion of human insulin in rats: potential for group housing

    DEFF Research Database (Denmark)

    Jensen, Vivi Flou Hjorth; Molck, Anne-Marie; Martensson, Martin

    2017-01-01

    compound in these studies, and a comparator model of persistent exposure by HI infusion from external pumps has recently been developed to support toxicological evaluation of long-acting insulin analogues. However, this model requires single housing of the animals. Developing an insulin-infusion model...... which allows group housing would therefore greatly improve animal welfare. The aim of the present study was to investigate the suitability of implantable infusion pumps for HI infusion in group-housed rats. Group housing of rats implanted with a battery-driven pump proved to be possible. Intravenous...... infusion of HI lowered blood glucose levels persistently for two weeks, providing a comparator model for use in two-week repeated-dose toxicity studies with new long-acting insulin analogues, which allows group housing, and thereby increasing animal welfare compared with an external infusion model....

  3. Effect of dose and size on defect engineering in carbon cluster implanted silicon wafers

    Science.gov (United States)

    Okuyama, Ryosuke; Masada, Ayumi; Shigematsu, Satoshi; Kadono, Takeshi; Hirose, Ryo; Koga, Yoshihiro; Okuda, Hidehiko; Kurita, Kazunari

    2018-01-01

    Carbon-cluster-ion-implanted defects were investigated by high-resolution cross-sectional transmission electron microscopy toward achieving high-performance CMOS image sensors. We revealed that implantation damage formation in the silicon wafer bulk significantly differs between carbon-cluster and monomer ions after implantation. After epitaxial growth, small and large defects were observed in the implanted region of carbon clusters. The electron diffraction pattern of both small and large defects exhibits that from bulk crystalline silicon in the implanted region. On the one hand, we assumed that the silicon carbide structure was not formed in the implanted region, and small defects formed because of the complex of carbon and interstitial silicon. On the other hand, large defects were hypothesized to originate from the recrystallization of the amorphous layer formed by high-dose carbon-cluster implantation. These defects are considered to contribute to the powerful gettering capability required for high-performance CMOS image sensors.

  4. Plasma Doping - Enabling Technology for High Dose Logic and Memory Applications

    International Nuclear Information System (INIS)

    Miller, T.; Godet, L.; Papasouliotis, G. D.; Singh, V.

    2008-01-01

    As logic and memory device dimensions shrink with each generation, there are more high dose implants at lower energies. Examples include dual poly gate (also referred to as counter-doped poly), elevated source drain and contact plug implants. Plasma Doping technology throughput and dopant profile benefits at these ultra high dose and lower energy conditions have been well established [1,2,3]. For the first time a production-worthy plasma doping implanter, the VIISta PLAD tool, has been developed with unique architecture suited for precise and repeatable dopant placement. Critical elements of the architecture include pulsed DC wafer bias, closed-loop dosimetry and a uniform low energy, high density plasma source. In this paper key performance metrics such as dose uniformity, dose repeatability and dopant profile control will be presented that demonstrate the production-worthiness of the VIISta PLAD tool for several high dose applications.

  5. High-temperature superconductors induced by ion implantation. Final report

    International Nuclear Information System (INIS)

    Greenwald, A.C.; Johnson, E.

    1988-08-01

    High dose oxygen ion implantation (10 to the 17th power ions per sq. cm.) at elevated temperatures (300 C) has been shown to adjust the critical temperature of gamma-Y-Ba-Cu-O and Bi-Ca-Sr-Cu-O materials. These results are in marked contrast to earlier work which showed complete destruction of superconducting properties for similar radiation doses, and marked reduction in superconducting properties at one-tenth this dose in the 1-2-3- compound only. Experiments also showed that the superconducting materials can be patterned into conducting and nonconducting areas without etching by ion implantation, allowing maintenance of planar geometries required for microcircuit fabrication. Experiments on deposition of thin films of high temperature superconductors for use with the ion implantation experiments showed that ion beam sputtering from a single target could achieve the correct stoichiometry. Variations of composition with ion beam energy and angle of sputtered ions were studied

  6. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ruijie, E-mail: ruijyang@yahoo.com; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-10-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

  7. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    International Nuclear Information System (INIS)

    Yang, Ruijie; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-01-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D 90 of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD 2 ) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D mean (EQD 2 ) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D mean (EQD 2 ) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD 2 ) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

  8. Postimplantation Analysis Enables Improvement of Dose-Volume Histograms and Reduction of Toxicity for Permanent Seed Implantation

    International Nuclear Information System (INIS)

    Wust, Peter; Postrach, Johanna; Kahmann, Frank; Henkel, Thomas; Graf, Reinhold; Cho, Chie Hee; Budach, Volker; Boehmer, Dirk

    2008-01-01

    Purpose: To demonstrate how postimplantation analysis is useful for improving permanent seed implantation and reducing toxicity. Patients and Methods: We evaluated 197 questionnaires completed by patients after permanent seed implantation (monotherapy between 1999 and 2003). For 70% of these patients, a computed tomography was available to perform postimplantation analysis. The index doses and volumes of the dose-volume histograms (DVHs) were determined and categorized with respect to the date of implantation. Differences in symptom scores relative to pretherapeutic status were analyzed with regard to follow-up times and DVH descriptors. Acute and subacute toxicities in a control group of 117 patients from an earlier study (June 1999 to September 2001) by Wust et al. (2004) were compared with a matched subgroup from this study equaling 110 patients treated between October 2001 and August 2003. Results: Improved performance, identifying a characteristic time dependency of DVH parameters (after implantation) and toxicity scores, was demonstrated. Although coverage (volume covered by 100% of the prescription dose of the prostate) increased slightly, high-dose regions decreased with the growing experience of the users. Improvement in the DVH and a reduction of toxicities were found in the patient group implanted in the later period. A decline in symptoms with follow-up time counteracts this gain of experience and must be considered. Urinary and sexual discomfort was enhanced by dose heterogeneities (e.g., dose covering 10% of the prostate volume, volume covered by 200% of prescription dose). In contrast, rectal toxicities correlated with exposed rectal volumes, especially the rectal volume covered by 100% of the prescription dose. Conclusion: The typical side effects occurring after permanent seed implantation can be reduced by improving the dose distributions. An improvement in dose distributions and a reduction of toxicities were identified with elapsed time between

  9. The dosimetric impact of implants on the spinal cord dose during stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Yazici, Gozde; Sari, Sezin Yuce; Yedekci, Fazli Yagiz; Yucekul, Altug; Birgi, Sumerya Duru; Demirkiran, Gokhan; Gultekin, Melis; Hurmuz, Pervin; Yazici, Muharrem; Ozyigit, Gokhan; Cengiz, Mustafa

    2016-01-01

    dose calculated by the TPS, respectively. Spinal implants may be present in the treatment field in patients scheduled to undergo SBRT. For the types of implants studied herein anterior rod instrumentation resulted in an increase in the spinal cord dose, whereas use of a titanium cage had a minimal effect on dose distribution. While planning SBRT in patients with spinal reconstructions, avoidance of the rod and preventing interaction between the rod and beam might be the optimal solution for preventing unexpectedly high spinal cord doses

  10. Reproductive toxicity in rats after chronic oral exposure to low dose of depleted uranium

    International Nuclear Information System (INIS)

    Li Rong; Ai Guoping; Xu Hui; Su Yongping; Cheng Tianmin; Leng Yanbing

    2007-01-01

    Objective: To study the reproductive toxicity in rats induced by low dose of depleted uranium (DU). Methods: Male and female rats(F 0 generation) were exposed to DU in food at doses of 0, 0.4, 4 and 40 mg·kg -1 ·d -1 for 160 days, respectively. Then the activities of enzymes in testis and sexual hormone contents in serum were detected. Mature male rats were mated with female rats exposed to the same doses for 14 days. Pregnant rate and normal labor rate in F 0 rats were detected, as well as the survival rate and weight of F 1 rats within 21 d after birth. Results: No adverse effects of DU on fertility were evident at any dose in F 0 rats. Compared with control group, the rate of pregnancy, normal labor, survival of offspring birth and offspring nurture in F 1 generation of high-dose group reduced to 40.0%, 33.3%, 33.3%, and 33.3%, respectively. The sexual hormone contents in F 0 generation exposed increased, but those in Fl rats decreased significantly. The activities of lactate dehydrogenase-X (LDH-X) decreased in F 1 rats exposed to high-dose of DU, and those of sorbitol dehydrogenase (SDH), LDH and Na + -K + -ATPase decreased in F 1 rats exposed to DU. Conclusions: Reproduction function, growth and development of F 0 rats are not obviously affected after chronic oral exposure to DU, while the toxicity effects in F 1 generation was observed at any dose. (authors)

  11. The environmental toxicant 2,3,7,8-tetrachlorodibenzo-p-dioxin disrupts morphogenesis of the rat pre-implantation embryo

    Directory of Open Access Journals (Sweden)

    Albertini David F

    2008-01-01

    Full Text Available Abstract Background Environmental toxicants, whose actions are often mediated through the aryl hydrocarbon receptor (AhR pathway, pose risks to the health and well-being of exposed species, including humans. Of particular concern are exposures during the earliest stages of development that while failing to abrogate embryogenesis, may have long term effects on newborns or adults. The purpose of this study was to evaluate the effect of maternal exposure to the AhR-specific ligand 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD on the development of rat pre-implantation embryos with respect to nuclear and cytoskeletal architecture and cell lineage allocation. Results We performed a systematic 3 dimensional (3D confocal microscopy analysis of rat pre-implantation embryos following maternal exposure to environmentally relevant doses of TCDD. Both chronic (50 ng/kg/wk for 3 months and acute (50 ng/kg and 1 μg/kg at proestrus maternal TCDD exposure disrupted morphogenesis at the compaction stage (8–16 cell, with defects including monopolar spindle formation, f-actin capping and fragmentation due to aberrant cytokinesis. Additionally, the size, shape and position of nuclei were modified in compaction stage pre-implantation embryos collected from treated animals. Notably, maternal TCDD exposure did not compromise survival to blastocyst, which with the exception of nuclear shape, were morphologically similar to control blastocysts. Conclusion We have identified the compaction stage of pre-implantation embryogenesis as critically sensitive to the effects of TCDD, while survival to the blastocyst stage is not compromised. To the best of our knowledge this is the first in vivo study to demonstrate a critical window of pre-implantation mammalian development that is vulnerable to disruption by an AhR ligand at environmentally relevant doses.

  12. Evaluation of porous vitreous carbon or silicon implants by radiology in rat's skull

    International Nuclear Information System (INIS)

    Vaccari-Mazzetti, Marcelo Paulo; Kobata, Celio Toshiro; Fabiani, Paulo; Martins, Dulce Maria Fonseca Soares; Gomes, Paulo de Oliveira; Martins, Jose Luiz

    2008-01-01

    Purpose: Evaluate by CT the use of porous vitreous carbon (PVC) and silicon (S) implants as the replacement bone in the craniofacial skeleton of rats. Methods: 40 rats divided in: Group A (n=20) PVC submitted to the implant of a fragment in skull. After the euthanasia, the animals were divided into two subgroups: A I: 10 animals, studied in the 7th postoperative day (P.O) and AII: 10 animals, studied in the 28th P.O. In group B, S, 20 rats were submitted to S implant in the skull. All other steps were identical to group A, with designation of subgroups BI and BII. CT with beams in axial cuts of 1 mm thickness to obtain 3-D information It was used Hounsfield scale for evaluate the radio density of the implant. They were used non parametric tests to analyze the results. Results: The 7th PO boss remained in the two groups, but for 28th PO, observed reduction in the volume of the implant in Group A, not observed in group B. CT studies noticed different radio densities around all of S prostheses (pseudo capsule), that do not appeared in CPV implants. The S has remained unchanged in the CT, but the CPV has had a modification in its radio density (p≤0,05), in all implants. Conclusion: In CT evaluation the implants of CPV have greater deformation that the S, which makes them not suitable for replacement of membranous bone in the rat skull. (author)

  13. Behavioral and cellular consequences of high-electrode count Utah Arrays chronically implanted in rat sciatic nerve

    Science.gov (United States)

    Wark, H. A. C.; Mathews, K. S.; Normann, R. A.; Fernandez, E.

    2014-08-01

    Objective. Before peripheral nerve electrodes can be used for the restoration of sensory and motor functions in patients with neurological disorders, the behavioral and histological consequences of these devices must be investigated. These indices of biocompatibility can be defined in terms of desired functional outcomes; for example, a device may be considered for use as a therapeutic intervention if the implanted subject retains functional neurons post-implantation even in the presence of a foreign body response. The consequences of an indwelling device may remain localized to cellular responses at the device-tissue interface, such as fibrotic encapsulation of the device, or they may affect the animal more globally, such as impacting behavioral or sensorimotor functions. The objective of this study was to investigate the overall consequences of implantation of high-electrode count intrafascicular peripheral nerve arrays, High Density Utah Slanted Electrode Arrays (HD-USEAs; 25 electrodes mm-2). Approach. HD-USEAs were implanted in rat sciatic nerves for one and two month periods. We monitored wheel running, noxious sensory paw withdrawal reflexes, footprints, nerve morphology and macrophage presence at the tissue-device interface. In addition, we used a novel approach to contain the arrays in actively behaving animals that consisted of an organic nerve wrap. A total of 500 electrodes were implanted across all ten animals. Main results. The results demonstrated that chronic implantation (⩽8 weeks) of HD-USEAs into peripheral nerves can evoke behavioral deficits that recover over time. Morphology of the nerve distal to the implantation site showed variable signs of nerve fiber degeneration and regeneration. Cytology adjacent to the device-tissue interface also showed a variable response, with some electrodes having many macrophages surrounding the electrodes, while other electrodes had few or no macrophages present. This variability was also seen along the length

  14. Vitamin E Phosphate Coating Stimulates Bone Deposition in Implant-related Infections in a Rat Model.

    Science.gov (United States)

    Lovati, Arianna B; Bottagisio, Marta; Maraldi, Susanna; Violatto, Martina B; Bortolin, Monica; De Vecchi, Elena; Bigini, Paolo; Drago, Lorenzo; Romanò, Carlo L

    2018-06-01

    Implant-related infections are associated with impaired bone healing and osseointegration. In vitro antiadhesive and antibacterial properties and in vivo antiinflammatory effects protecting against bone loss of various formulations of vitamin E have been demonstrated in animal models. However, to the best of our knowledge, no in vivo studies have demonstrated the synergistic activity of vitamin E in preventing bacterial adhesion to orthopaedic implants, thus supporting the bone-implant integration. The purpose of this study was to test whether a vitamin E phosphate coating on titanium implants may be able to reduce (1) the bacterial colonization of prosthetic implants and (2) bone resorption and osteomyelitis in a rat model of Staphylococcus aureus-induced implant-related infection. Twelve rats were bilaterally injected in the femurs with S aureus UAMS-1-Xen40 and implanted with uncoated or vitamin E phosphate-coated titanium Kirschner wires without local or systemic antibiotic prophylaxis. Eight rats represented the uninfected control group. A few hours after surgery, two control and three infected animals died as a result of unexpected complications. With the remaining rats, we assessed the presence of bacterial contamination with qualitative bioluminescence imaging and Gram-positive staining and with quantitative bacterial count. Bone changes in terms of resorption and osteomyelitis were quantitatively analyzed through micro-CT (bone mineral density) and semiquantitatively through histologic scoring systems. Six weeks after implantation, we found only a mild decrease in bacterial count in coated versus uncoated implants (Ti versus controls: mean difference [MD], -3.705; 95% confidence interval [CI], -4.416 to -2.994; p E-treated group compared with uncoated implants (knee joint: MD, -11.88; 95% CI, -16.100 to -7.664; p E-coated nails compared with the uncoated nails. These preliminary findings indicate that vitamin E phosphate implant coatings can exert a

  15. Effects of pore size, implantation time and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants

    OpenAIRE

    Farrell, Brad J.; Prilutsky, Boris I.; Ritter, Jana M.; Kelley, Sean; Popat, Ketul; Pitkin, Mark

    2013-01-01

    The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40–100 microns and Large, 100–160 microns), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to 7 groups. Implant extrusion rate was measured w...

  16. Increased expression of heat shock protein 105 in rat uterus of early pregnancy and its significance in embryo implantation

    Directory of Open Access Journals (Sweden)

    Hu Zhao-Yuan

    2009-03-01

    Full Text Available Abstract Background Heat shock proteins (Hsps are a set of highly conserved proteins, Hsp105, has been suggested to play a role in reproduction. Methods Spatio-temporal expression of Hsp105 in rat uterus during peri-implantation period was examined by immunohistochemistry and Western blot, pseudopregnant uterus was used as control. Injection of antisense oligodeoxynucleotides to Hsp105 into pregnant rat uteri was carried out to look at effect of Hsp105 on embryo implantation. Results Expression of Hsp105 was mainly in the luminal epithelium on day 1 of pregnancy, and reached a peak level on day 5, whereas in stroma cells, adjacent to the implanting embryo, the strongest expression of Hsp105 was observed on day 6. The immunostaining profile in the uterus was consistent with that obtained by Western blot in the early pregnancy. In contrast, no obvious peak level of Hsp105 was observed in the uterus of pseudopregnant rat on day 5 or day 6. Furthermore, injection of antisense oligodeoxynucleotides to Hsp105 into the rat uterine horn on day 3 of pregnancy obviously suppressed the protein expression as expected and reduced number of the implanted embryos as compared with the control. Conclusion Temporal and spatial changes in Hsp105 expression in pregnant rat uterus may play a physiological role in regulating embryo implantation.

  17. Fluoxetine Dose and Administration Method Differentially Affect Hippocampal Plasticity in Adult Female Rats

    Science.gov (United States)

    Pawluski, Jodi L.; van Donkelaar, Eva; Abrams, Zipporah; Steinbusch, Harry W. M.; Charlier, Thierry D.

    2014-01-01

    Selective serotonin reuptake inhibitor medications are one of the most common treatments for mood disorders. In humans, these medications are taken orally, usually once per day. Unfortunately, administration of antidepressant medications in rodent models is often through injection, oral gavage, or minipump implant, all relatively stressful procedures. The aim of the present study was to investigate how administration of the commonly used SSRI, fluoxetine, via a wafer cookie, compares to fluoxetine administration using an osmotic minipump, with regards to serum drug levels and hippocampal plasticity. For this experiment, adult female Sprague-Dawley rats were divided over the two administration methods: (1) cookie and (2) osmotic minipump and three fluoxetine treatment doses: 0, 5, or 10 mg/kg/day. Results show that a fluoxetine dose of 5 mg/kg/day, but not 10 mg/kg/day, results in comparable serum levels of fluoxetine and its active metabolite norfluoxetine between the two administration methods. Furthermore, minipump administration of fluoxetine resulted in higher levels of cell proliferation in the granule cell layer (GCL) at a 5 mg dose compared to a 10 mg dose. Synaptophysin expression in the GCL, but not CA3, was significantly lower after fluoxetine treatment, regardless of administration method. These data suggest that the administration method and dose of fluoxetine can differentially affect hippocampal plasticity in the adult female rat. PMID:24757568

  18. Fluoxetine Dose and Administration Method Differentially Affect Hippocampal Plasticity in Adult Female Rats

    Directory of Open Access Journals (Sweden)

    Jodi L. Pawluski

    2014-01-01

    Full Text Available Selective serotonin reuptake inhibitor medications are one of the most common treatments for mood disorders. In humans, these medications are taken orally, usually once per day. Unfortunately, administration of antidepressant medications in rodent models is often through injection, oral gavage, or minipump implant, all relatively stressful procedures. The aim of the present study was to investigate how administration of the commonly used SSRI, fluoxetine, via a wafer cookie, compares to fluoxetine administration using an osmotic minipump, with regards to serum drug levels and hippocampal plasticity. For this experiment, adult female Sprague-Dawley rats were divided over the two administration methods: (1 cookie and (2 osmotic minipump and three fluoxetine treatment doses: 0, 5, or 10 mg/kg/day. Results show that a fluoxetine dose of 5 mg/kg/day, but not 10 mg/kg/day, results in comparable serum levels of fluoxetine and its active metabolite norfluoxetine between the two administration methods. Furthermore, minipump administration of fluoxetine resulted in higher levels of cell proliferation in the granule cell layer (GCL at a 5 mg dose compared to a 10 mg dose. Synaptophysin expression in the GCL, but not CA3, was significantly lower after fluoxetine treatment, regardless of administration method. These data suggest that the administration method and dose of fluoxetine can differentially affect hippocampal plasticity in the adult female rat.

  19. Preparation and biocompatibility study of in situ forming polymer implants in rat brains.

    Science.gov (United States)

    Nasongkla, Norased; Boongird, Atthaporn; Hongeng, Suradej; Manaspon, Chawan; Larbcharoensub, Noppadol

    2012-02-01

    We describe the development of polymer implants that were designed to solidify once injected into rat brains. These implants comprised of glycofurol and copolymers of D: ,L: -lactide (LA), ε-caprolactone and poly(ethylene glycol) (PLECs). Scanning electron microscopy (SEM) and gel permeation chromatography (GPC) showed that the extent of implant degradation was increased with LA: content in copolymers. SEM analysis revealed the formation of porosity on implant surface as the degradation proceeds. PLEC with 19.3% mole of LA: was chosen to inject in rat brains at the volume of 10, 25 and 40 μl. Body weights, hematological and histopathological data of rats treated with implants were evaluated on day 3, 6, 14, 30 and 45 after the injection. Polymer solution at the injection volume of 10 μl were tolerated relatively well compared to those of 25 and 40 μl as confirmed by higher body weight and healing action (fibrosis tissue) 30 days after treatment. The results from this study suggest a possible application as drug delivery systems that can bypass the blood brain barrier.

  20. First symposium seed implant 125I and high rate of prostate

    International Nuclear Information System (INIS)

    2012-01-01

    The First symposium seed implant 125 I and high rate of prostate, was organized by the Marie Curie Foundation, between the 12 to april 2012, in the Cordoba city of Argentina. In this event were presented several documents in different topics: patients selection for impacts of 125 I seeds; high doses radiation in radiotherapy; brachytherapy for prostate cancer; prostate implant technique with 125 I seeds; implant dosimetric aspects; radioprotection of 125 I seeds.

  1. High-dose thiamine therapy counters dyslipidemia and advanced glycation of plasma protein in streptozotocin-induced diabetic rats.

    Science.gov (United States)

    Karachalias, Nikolaos; Babaei-Jadidi, Roya; Kupich, Christian; Ahmed, Naila; Thornalley, Paul J

    2005-06-01

    The streptozotocin-induced (STZ) diabetic rat experimental model of diabetes on insulin maintenance therapy exhibits dyslipidemia, mild thiamine deficiency, and increased plasma protein advanced glycation end products (AGEs). The reversal of thiamine deficiency by high-dose thiamine and S-benzoylthiamine monophosphate (benfotiamine) prevented the development of incipient nephropathy. Recently, we reported that high-dose thiamine (but not benfotiamine) countered diabetic dyslipidemia. To understand further the differences between the effects of thiamine and benfotiamine therapy, we quantified the levels of the AGEs in plasma protein. We found hydroimidazolone AGE residues derived from glyoxal and methylglyoxal, G-H1 and MG-H1, were increased 115% and 68% in STZ diabetic rats, with respect to normal controls, and were normalized by both thiamine and benfotiamine; whereas N-carboxymethyl-lysine (CML) and N-carboxyethyl-lysine (CEL) residues were increased 74% and 118% in STZ diabetic rats and were normalized by thiamine only. The lack of effect of benfotiamine on plasma CML and CEL residue concentrations suggests there may be important precursors of plasma protein CML and CEL residues other than glyoxal and methylglyoxal. These are probably lipid-derived aldehydes.

  2. Influence of Statins locally applied from orthopedic implants on osseous integration

    Directory of Open Access Journals (Sweden)

    Pauly Stephan

    2012-10-01

    Full Text Available Abstract Background Simvastatin increases the expression of bone morphogenetic protein 2 (BMP-2 in osteoblasts, therefore it is important to investigate the influence of statins on bone formation, fracture healing and implant integration. The aim of the present study was to investigate the effect of Simvastatin, locally applied from intramedullary coated and bioactive implants, on bone integration using biomechanical and histomorphometrical analyses. Methods Eighty rats received retrograde nailing of the femur with titanium implants: uncoated vs. polymer-only (poly(D,L-lactide vs. polymer plus drug coated (either Simvastatin low- or high dosed; “SIM low/ high”. Femurs were harvested after 56 days for radiographic and histomorphometric or biomechanical analysis (push-out. Results Radiographic analysis revealed no pathological findings for animals of the control and SIM low dose group. However, n=2/10 animals of the SIM high group showed osteolysis next to the implant without evidence of bacterial infection determined by microbiological analysis. Biomechanical results showed a significant decrease in fixation strength for SIM high coated implants vs. the control groups (uncoated and PDLLA. Histomorphometry revealed a significantly reduced total as well as direct bone/implant contact for SIM high- implants vs. controls (uncoated and PDLLA-groups. Total contact was reduced for SIM low vs. uncoated controls. Significantly reduced new bone formation was measured around SIM high coated implants vs. both control groups. Conclusions This animal study suggests impaired implant integration with local application of Simvastatin from intramedullary titanium implants after 8 weeks when compared to uncoated or carrier-only coated controls.

  3. Design of an end station for a high current ion implantation system

    International Nuclear Information System (INIS)

    Kranik, J.R.

    1979-01-01

    During the last 4 to 5 years IBM has been involved in an effort to develop a high current Ion Implantation system with pre-deposition capabilities. The system is dedicated to Arsenic implants, involving doses > 1 x 10 15 ions/cm 2 in the energy range of 30 to 60 keV. A major portion of this effort involved the design of an associated end station capable of producing high uniformity implants with beam currents in the 0.5 to 6.0 mA range. The end station contains all components from the exit of the analyzing magnet, including the exit beamline, process chamber, scan system, wafer handling system, high vacuum pumping package, beam optics, dosimetry system, and associated electronic controls. The unit was restricted to a six wafer (82 mm) batch size to maintain process line compatibility. In addition, implant dose non-uniformity objectives were established at +- 3% (2σ) within a wafer and +- 2% (2σ) wafer-to-wafer. Also, the system was to be capable of implanting 24 wafers/hour at a dose of 7.5 x 10 15 ions/cm 2 . Major consideration in the design was afforded to high reliability, ease of maintenance and production level throughput capabilities. The rationale and evolution of the final end station design is described. (author)

  4. Implanted, inductively-coupled, radiofrequency coils fabricated on flexible polymeric material: Application to in vivo rat brain MRI at 7 T

    International Nuclear Information System (INIS)

    Ginefri, J.C.; Poirier-Quinot, M.; Darrasse, L.; Rubin, A.; Tatoulian, M.; Woytasik, M.; Boumezbeur, F.; Djemai, B.; Lethimonnier, F.

    2012-01-01

    Combined with high-field MRI scanners, small implanted coils allow for high resolution imaging with locally improved SNR, as compared to external coils. Small flexible implantable coils dedicated to in vivo MRI of the rat brain at 7 T were developed. Based on the Multi-turn Transmission Line Resonator design, they were fabricated with a Teflon substrate using copper micro-molding process and a specific metal-polymer adhesion treatment. The implanted coils were made biocompatible by Polydimethylsiloxane (PDMS) encapsulation. The use of low loss tangent material achieves low dielectric losses within the substrate and the use of the PDMS layer reduces the parasitic coupling with the surrounding media. An implanted coil was implemented in a 7 T MRI system using inductive coupling and a dedicated external pick-up coil for signal transmission. In vivo images of the rat brain acquired with in plane resolution of (150 μm) 2 thanks to the implanted coil revealed high SNR near the coil, allowing for the visualization of fine cerebral structures. (authors)

  5. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    Science.gov (United States)

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  6. Absorption, Distribution, and Excretion of 14C-APX001 after Single-Dose Administration to Rats and Monkeys

    Science.gov (United States)

    Mansbach, Robert; Shaw, Karen J; Hodges, Michael R; Coleman, Samantha; Fitzsimmons, Michael E

    2017-01-01

    Abstract Background APX001 is a small-molecule therapeutic agent in clinical development for the treatment of invasive fungal infections (IFI). Methods The absorption, distribution and excretion profiles of [14C]APX001-derived radioactivity were determined in rats (albino and pigmented) and monkeys. Rats (some implanted with bile duct cannulae) were administered a single 100 mg/kg oral dose or a 30 mg/kg intravenous (IV) dose. Monkeys were administered a single 6 mg/kg IV dose. Samples of blood, urine, feces and bile, as well as carcasses, were collected through 168 hours after dosing. Samples were analyzed for total radioactivity content by liquid scintillation counting, and carcasses were analyzed by quantitative whole-body autoradiography. Results [14C]APX001-derived radioactivity was rapidly and extensively absorbed and extensively distributed to most tissues for both routes of administration in both species. In rats, tissues with the highest radioactivity Cmax values included bile, abdominal fat, reproductive fat, subcutaneous fat, and liver, but radioactivity was also detected in tissues associated with IFI, including lung, brain and eye. In monkeys, the highest Cmax values were in bile, urine, uveal tract, bone marrow, abdominal fat, liver, and kidney cortex. Liver and kidney were the tissues with highest radioactivity, but as in the rat, radioactivity was also detected in lung, brain and eye tissues. In pigmented rats, radiocarbon was densely distributed into pigmented tissue and more slowly cleared than from other tissues. Mean recovery of radioactivity in rats was approximately 95–100%. In bile duct-intact rats, >90% of radioactivity was recovered in feces. In cannulated rats, biliary excretion of radioactivity was the major route of elimination and accounted for 88.8% of the dose, whereas urinary and fecal excretion of radioactivity was minor and accounted for 2.56% and 5.42% of the dose, respectively. In monkeys, the overall recovery of radioactivity

  7. Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

    Science.gov (United States)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-03-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.

  8. Influence of metallic dental implants and metal artefacts on dose calculation accuracy

    International Nuclear Information System (INIS)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-01-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic trademark EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques. (orig.) [de

  9. Dose dependent disposition of gallium-67 in rats

    International Nuclear Information System (INIS)

    Gautam, S.R.

    1982-01-01

    Radioactive gallium-67 has been employed as a diagnostic and follow-up agent for cancer therapy. Currently gallium nitrate is undergoing Phase I clinical studies. A million fold increase in the concentration of the carrier gallium citrate over the range of carrier-free gallium-67 (pgm) to 1.0 μg caused no significant alteration in the disposition of gallium-67 in rats.Gallium-67 was eliminated from blood with a biological t1/2 of 4.1 days. A linear tissue binding profile was observed for gallium-67 over this concentration range. A multi-compartment pharmacokinetic model was developed in which all the tissues studied were treated as separate compartments. At 1.0 mg dose level, significant alteration in the disposition of gallium-67 was observed in rats, > 95% of the initial radioactivity was characteristic reappearance of the radioactivity in the blood approximately 4 hours after dosing leading to a ''hump'' in the blood concentration-time profiles. Following the 1.0 mg dose low tissue levels were observed, except for the kidneys, which contained about 8% of the administered dose per gram of the tissue one-half hour after dosing. A non-linear tissue binding profile was observed to be associated with gallium at high doses. It was hypothesized that the rapid loss of gallium-67 from the vascular system following the high doses of gallium citrate was due to the accumulation of the drug in the kidneys where it was eventually eliminated via urine. The kidneys thus would act as a temporary storage site for gallium. It was concluded that the dose-related renal toxicity associated with gallium therapy may be attributed to the kidney's role as a temporary storage site following high doses

  10. HEALING OF MICROVENOUS PTFE PROSTHESES IMPLANTED INTO THE RAT FEMORAL VEIN

    NARCIS (Netherlands)

    VANDERLEI, B; DIJK, F; JONGEBLOED, WL; ROBINSON, PH; Bartels, H.

    44 PTFE prostheses (Gore-Tex(R); ID 1 mm) were implanted into rats' femoral veins by means of the sleeve anastomotic technique and were evaluated at regular intervals from 1 h up till 24 weeks after implantation by means of light and electron microscopy to study in detail their healing process. All

  11. ANTI-DIABETIC EFFECTS OF TURMERIC IN ALLOXAN INDUCE D DIABETIC RATS

    OpenAIRE

    Jeevangi; Manjunath; Deepak D; Prakash G; Prashant; Chetan

    2013-01-01

    ABSTRACT: OBJECTIVE AND BACKGROUND: Turmeric (Curcuma longa) is one of the common constituents of our daily food. The present study wa s undertaken to evaluate the anti-diabetic effects of ethanolic extract of Rhizomes of curcuma longa in alloxan induced diabetic rats and compared with of Pioglitazone, which is the standard anti-diabetic agent. METHODS: Alloxan monohydrate is used to induce diabetes mellitus in albino rats in the dose of 120mg/kg i.p. and ...

  12. Utafiti Wa Lahaja Za Kiswahili: Uzoefu Wa Uwandani | Ismail ...

    African Journals Online (AJOL)

    Katika ujumla wake, historia ya utafiti, na hasa utafiti wa uwandani, ni historia ya jitihada za binadamu katika kujishughulisha kwake ili ayaelewe masuala mengi mtambuka katika mazingira fungamanishi. Hakuna mtafiti yeyote anayeweza kudai kuwa utafiti wa mada fulani katika eneo fulani umekamilika na ...

  13. Effects of pore size, implantation time, and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants.

    Science.gov (United States)

    Farrell, Brad J; Prilutsky, Boris I; Ritter, Jana M; Kelley, Sean; Popat, Ketul; Pitkin, Mark

    2014-05-01

    The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40-100 μm and Large, 100-160 μm), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to seven groups. Implant extrusion rate was measured weekly and skin ingrowth into implants was determined histologically after harvesting implants. It was found that all three types of implants demonstrated skin tissue ingrowth of over 30% (at week 3) and 50% (at weeks 4-6) of total implant porous area under the skin; longer implantation resulted in greater skin ingrowth (p skin integration with the potential for a safe seal. Copyright © 2013 Wiley Periodicals, Inc.

  14. Mabadiliko Ya Kifonolojia Na Kimofolojia Wakati Wa Utohozi Wa ...

    African Journals Online (AJOL)

    Mwingiliano wa lugha ya Kiswahili na Kiarabu una historia ndefu kidogo. Inasemekana Waarabu walianza muwasala na 'Waswahili' tangu karne ya kwanza (BK) (Polome 1967:9). Kutokana na muwasala huo wa muda mrefu, lugha hizi mbili (Kiarabu na Kiswahili) zimeathiriana sana. Lakini kuna maoni kwamba Kiarabu ...

  15. Evaluation of failure modes of computerized planning phase of interstitial implants with high dose rate brachytherapy using HFMEA

    International Nuclear Information System (INIS)

    Biazotto, Bruna; Tokarski, Marcio

    2014-01-01

    This paper evaluates the failure modes of the computerized planning step in interstitial implants with high dose rate brachytherapy. The prospective tool of risk management Health Care Failure Mode and Effects Analysis (HFMEA) was used. Twelve subprocesses were identified, and 33 failure modes of which 21 justified new safety actions, and 9 of them were intolerable risks. The method proved itself useful in identifying failure modes, but laborious and subjective in their assessment. The main risks were due to human factors, which require training and commitment of management to their mitigation. (author)

  16. Neuroprotection and mechanisms of atractylenolide III in preventing learning and memory impairment induced by chronic high-dose homocysteine administration in rats.

    Science.gov (United States)

    Zhao, H; Ji, Z-H; Liu, C; Yu, X-Y

    2015-04-02

    Studies demonstrated that chronic high-dose homocysteine administration induced learning and memory impairment in animals. Atractylenolide III (Aen-III), a neuroprotective constituent of Atractylodis macrocephalae Koidz, was isolated in our previous study. In this study, we investigated potential benefits of Aen-III in preventing learning and memory impairment following chronic high-dose homocysteine administration in rats. Results showed that administration of Aen-III significantly ameliorated learning and memory impairment induced by chronic high-dose homocysteine administration in rats, decreased homocysteine-induced reactive oxygen species (ROS) formation and restored homocysteine-induced decrease of phosphorylated protein kinase C expression level. Moreover, Aen-III protected primary cultured neurons from apoptotic death induced by homocysteine treatment. This study provides the first evidence for the neuroprotective effect of Aen-III in preventing learning and impairment induced by chronic administration of homocysteine. Aen-III may have therapeutic potential in treating homocysteine-mediated cognitive impairment and neuronal injury. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  17. Total dose hardening of buried insulator in implanted silicon-on-insulator structures

    International Nuclear Information System (INIS)

    Mao, B.Y.; Chen, C.E.; Pollack, G.; Hughes, H.L.; Davis, G.E.

    1987-01-01

    Total dose characteristics of the buried insulator in implanted silicon-on-insulator (SOI) substrates have been studied using MOS transistors. The threshold voltage shift of the parasitic back channel transistor, which is controlled by charge trapping in the buried insulator, is reduced by lowering the oxygen dose as well as by an additional nitrogen implant, without degrading the front channel transistor characteristics. The improvements in the radiation characteristics of the buried insulator are attributed to the decrease in the buried oxide thickness or to the presence of the interfacial oxynitride layer formed by the oxygen and nitrogen implants

  18. Early Effect of High Dose of Ionizing Radiation Exposure on Plasma Lipids Profile and Liver Fatty Acids Composition in Rats

    International Nuclear Information System (INIS)

    Noaman, E.; Mansour, S.Z.; Ibrahim, N.K.

    2005-01-01

    The present study was conducted to analyze the effect of acute gamma-irradiation on rats at supralethal doses of 20 Gy to determine the synthesis and amounts of free fatty acids, neutral lipids and phospholipids of plasma and liver after 24 and 48 h of gamma-irradiation. Male Wistar rats weighing 120+- 20 g were exposed to 20 Gy of gamma radiation (dose rate of 0.59 Gy/min). Exposure of rats to ionizing radiation resulted in significant alterations in the assayed parameters indicating lipid metabolism disturbance. Plasma cholesterol and phospholipid levels increased up to 71.3 and 71.5 %, respectively, after 24 h from radiation exposure and then returned to 28 and 27 % change in-compare with control values after 48 h post-irradiation. Plasma triacylglycerol concentrations increased concomitantly with irradiation, but their values are less high than cholesterol and phospholipid levels recording significant changes at 19 and 9 % comparing with control rats. Lipid peroxidation measured as MDA recorded significant elevation after 24 and 48 h post irradiation. It was shown that the synthesis of free fatty acids, cholesterol, cholesterol ethers and phospholipids was activated 48 h after irradiation at 20 Gy. The amount of free fatty acids of the rat liver decreased at 20 Gy exposures. This is assumed to be a result of the radioresistance to some degree in the system of free fatty acid synthesis of the rat to the gamma-irradiation in the lethal doses

  19. Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiae.

    Science.gov (United States)

    Torcasio, Antonia; Zhang, Xiaolei; Van Oosterwyck, Hans; Duyck, Joke; van Lenthe, G Harry

    2012-05-01

    Although research has been addressed at investigating the effect of specific loading regimes on bone response around the implant, a precise quantitative understanding of the local mechanical response close to the implant site is still lacking. This study was aimed at validating micro-CT-based finite element (μFE) models to assess tissue strains after implant placement in a rat tibia. Small implants were inserted at the medio-proximal site of 8 rat tibiae. The limbs were subjected to axial compression loading; strain close to the implant was measured by means of strain gauges. Specimen-specific μFE models were created and analyzed. For each specimen, 4 different models were created corresponding to different representations of the bone-implant interface: bone and implant were assumed fully osseointegrated (A); a low stiffness interface zone was assumed with thickness of 40 μm (B), 80 μm (C), and 160 μm (D). In all cases, measured and computational strains correlated highly (R (2) = 0.95, 0.92, 0.93, and 0.95 in A, B, C, and D, respectively). The averaged calculated strains were 1.69, 1.34, and 1.15 times higher than the measured strains for A, B, and C, respectively, and lower than the experimental strains for D (factor = 0.91). In conclusion, we demonstrated that specimen-specific FE analyses provide accurate estimates of peri-implant bone strains in the rat tibia loading model. Further investigations of the bone-implant interface are needed to quantify implant osseointegration.

  20. Protective effect of pioglitazone on cardiomyocyte apoptosis in low-dose streptozotocin & high-fat diet-induced type-2 diabetes in rats

    Directory of Open Access Journals (Sweden)

    Uma Bhandari

    2015-01-01

    Full Text Available Background & objectives: Cardiomyocyte apoptosis is one of the pathologic phenomena associated with diabetes and related conditions including obesity, insulin resistance and hyperlipidaemia. In the present study, the protective effects of pioglitazone on cardiomyocyte apoptosis was evaluated in experimental diabetes induced by low dose of streptozoticin (STZ combined with high fat diet (HFD in rats. Methods: Male Wistar rats (150-200 g were injected with low-dose STZ (45 mg/kg, i.v., single dose and orally fed with a HFD (20 g/day/rat for a period of 28 days and simultaneously treated with pioglitazone (20 mg/kg/p.o. for a period of 21 days (from 8 th day to 28 th day. On 29 th day blood was collected, serum separated and used for biochemical parameters. Heart tissue was used for cardiomyocyte apoptosis measurement and also for histopathological examination. Results: Pioglitazone treatment resulted in a decrease in cardiomyocyte apoptosis as revealed by a decrease in cardiac caspase-3, lactate dehydrogenase (LDH levels and DNA fragmentation, and an increase in Na+K+ATPase levels in diabetic rats. Cardiac histology of diabetic control rats showed dense focal fatty infiltration in the myocardial cells whereas normal architecture with regular morphology and well preserved cytoplasm was observed with pioglitazone treatment. Pioglitazone treatment significantly reduced the heart rate, mean arterial blood pressure, body mass index (BMI and levels of serum glucose, leptin, insulin, HOMA-IR, total cholesterol (TC and triglycerides (TGs, apoliproprotein-B glycosylated haemoglobin (HbA1c levels and atherogenic index, and increased the levels of serum high density lipoprotein cholesterol (HDL-C and cardiac antioxidant enzymes. Interpretation & conclusions: The present study results suggest that pioglitazone possesses cardiac anti-apoptotic potential in diabetic rat model and can be further explored for its use for treatment of diabetic cardiomyopathy.

  1. Dose perturbation effect of metallic spinal implants in proton beam therapy.

    Science.gov (United States)

    Jia, Yingcui; Zhao, Li; Cheng, Chee-Wai; McDonald, Mark W; Das, Indra J

    2015-09-08

    The purpose of this study was to investigate the effect of dose perturbations for two metallic spinal screw implants in proton beam therapy in the perpendicular and parallel beam geometry. A 5.5 mm (diameter) by 45 mm (length) stainless steel (SS) screw and a 5.5 mm by 35 mm titanium (Ti) screw commonly used for spinal fixation were CT-scanned in a hybrid phantom of water and solid water. The CT data were processed with an orthopedic metal artifact reduction (O-MAR) algorithm. Treatment plans were generated for each metal screw with a proton beam oriented, first parallel and then perpendicular, to the longitudinal axis of the screw. The calculated dose profiles were compared with measured results from a plane-parallel ion chamber and Gafchromic EBT2 films. For the perpendicular setup, the measured dose immediately downstream from the screw exhibited dose enhancement up to 12% for SS and 8% for Ti, respectively, but such dose perturbation was not observed outside the lateral edges of the screws. The TPS showed 5% and 2% dose reductions immediately at the interface for the SS nd Ti screws, respectively, and up to 9% dose enhancements within 1 cm outside of the lateral edges of the screws. The measured dose enhancement was only observed within 5 mm from the interface along the beam path. At deeper depths, the lateral dose profiles appeared to be similar between the measurement and TPS, with dose reduction in the screw shadow region and dose enhancement within 1-2 cm outside of the lateral edges of the metals. For the parallel setup, no significant dose perturbation was detected at lateral distance beyond 3 mm away from both screws. Significant dose discrepancies exist between TPS calculations and ion chamber and film measurements in close proximity of high-Z inhomogeneities. The observed dose enhancement effect with proton therapy is not correctly modeled by TPS. An extra measure of caution should be taken when evaluating dosimetry with spinal metallic implants.

  2. Formation of radiative centers in SiO2 by tin high-dose implantation

    International Nuclear Information System (INIS)

    Komarov, F.F.; Parkhomenko, I.N.; Vlasukova, L.A.; Mil'chanin, O.V.; Mokhovikov, M.A.; Wendler, E.; Wesch, W.

    2013-01-01

    The structural transformations in SiO 2 layers implanted with high fluence of Sn ions have been investigated. It has been found that post-implantation annealing results in the β-Sn precipitation as well as the formation of SnO 2 -enriched regions in SiO 2 :Sn matrix. The intensive emission in the range of photon energies 1.5 – 3.5 eV is registered for the implanted and annealed samples. We attribute it to the oxygen deficiency centers created in the SiO 2 :Sn matrix and at the 'nanocluster/SiO 2 ' interfaces. (authors)

  3. Histology study on the dorsal root ganglia of rats with 125I seed brachytherapy at intervertebral foramen

    International Nuclear Information System (INIS)

    Zhang Wenyi; Wang Huixing; Ding Yanqiu; Qu Ximei; Wang Liqin; Liu Zhongchao; Cui Songye; Jiao Ling

    2012-01-01

    Objective: To investigate the effect of the histological changes on rat dorsal root ganglia (DRG) after 125 I seed brachytherapy.Methods Twelve adult male Sprague-Dawley rats (150-180 g each) were randomly divided into 6 groups, 125 I seeds with different activities of 0 (Titanium shell), 14.8, 18.5, 22.2, 25.9 and 29.6 MBq were implanted to 6 groups of rats respectively and the behavioral changes of rats were observed. The rats were killed in different periods after implantation,the morphological changes in DRG and surrounding muscle tissue were observed with an Olympus BX51 optical microscope and then the irradiation doses were estimated. Results: After 125 I seed implantation, the movement function of rats was not affected and the weight of rats gained after 7 days. After the titanium shell implantation, very few mild swelling was induced in neuroganglion cells that still had clear nucleolus and normal cytoplasm. At 14 days after 18.5 MBq seed implantation, cell swelling was more serious and cell dehydrating, nuclear condensation and nuclear fragmentation appeared after 30 days. At 60 days after 29.6 MBq of seed implantation, nuclear dissolution and cytoplasmic shrinkage were induced in a large number of cells.In general, the severity of fibrosis was aggravated with the time post-irradiation and the dose in the muscles around the ganglion. Conclusions: After 125 I seed implantation,the injury degree of DRG tissue is dose-dependent, and the 125 I seed irradiation would have analgesic effect on releasing intractable pain. (authors)

  4. Biologically effective dose (BED) for interstitial seed implants containing a mixture of radionuclides with different half-lives

    International Nuclear Information System (INIS)

    Chen Zhe; Nath, Ravinder

    2003-01-01

    Purpose: To develop a tool for evaluating interstitial seed implants that contain a mixture of radionuclides with different half-lives and to demonstrate its utility by examining the clinical implications of prescribing to an isodose surface for such an implant. Methods and Materials: A linear-quadratic model for continuous low dose rate irradiation was developed for permanent implants containing a mixture of radionuclides. Using a generalized equation for the biologically effective dose (BED), the effects of cell proliferation and sublethal damage repair were examined systematically for implants containing a mixture of radionuclides. A head-and-neck permanent seed implant that contained a mixture of 125 I and 103 Pd seeds was used to demonstrate the utility of the generalized BED. Results: An equation of BED for implants containing a mixture of radionuclides with different half-lives was obtained. In such an implant, the effective cell kill was shown to depend strongly on the relative dose contributions from each radionuclide type; dose delivered by radionuclides with shorter half-life always resulted in more cell kill for any given sublethal damage repair and cell proliferation rates. Application of the BED formula to an implant containing a mixture of 125 I and 103 Pd seeds demonstrates that the conventional dose prescription to an isodose surface is not unique for such an implant. When the prescription dose was based on existing clinical experience of using 125 I seeds alone, mixing 103 Pd seeds with 125 I seeds would increase the cell kill. On the other hand, if the prescription dose were based on existing clinical experience of using 103 Pd seeds alone, mixing 125 I seeds with 103 Pd seeds in the same implant would create radiobiologically 'cold' spots (i.e., an increase in cell survival) at locations where a major portion of the prescription dose is contributed by the 125 I seeds. For fast-growing tumors, these 'cold' spots can become significant

  5. Anesthesia with Dexmedetomidine and Low-dose Isoflurane Increases Solute Transport via the Glymphatic Pathway in Rat Brain When Compared with High-dose Isoflurane.

    Science.gov (United States)

    Benveniste, Helene; Lee, Hedok; Ding, Fengfei; Sun, Qian; Al-Bizri, Ehab; Makaryus, Rany; Probst, Stephen; Nedergaard, Maiken; Stein, Elliot A; Lu, Hanbing

    2017-12-01

    The glymphatic pathway transports cerebrospinal fluid through the brain, thereby facilitating waste removal. A unique aspect of this pathway is that its function depends on the state of consciousness of the brain and is associated with norepinephrine activity. A current view is that all anesthetics will increase glymphatic transport by inducing unconsciousness. This view implies that the effect of anesthetics on glymphatic transport should be independent of their mechanism of action, as long as they induce unconsciousness. We tested this hypothesis by comparing the supplementary effect of dexmedetomidine, which lowers norepinephrine, with isoflurane only, which does not. Female rats were anesthetized with either isoflurane (N = 8) or dexmedetomidine plus low-dose isoflurane (N = 8). Physiologic parameters were recorded continuously. Glymphatic transport was quantified by contrast-enhanced magnetic resonance imaging. Cerebrospinal fluid and gray and white matter volumes were quantified from T1 maps, and blood vessel diameters were extracted from time-of-flight magnetic resonance angiograms. Electroencephalograms were recorded in separate groups of rats. Glymphatic transport was enhanced by 32% in rats anesthetized with dexmedetomidine plus low-dose isoflurane when compared with isoflurane. In the hippocampus, glymphatic clearance was sixfold more efficient during dexmedetomidine plus low-dose isoflurane anesthesia when compared with isoflurane. The respiratory and blood gas status was comparable in rats anesthetized with the two different anesthesia regimens. In the dexmedetomidine plus low-dose isoflurane rats, spindle oscillations (9 to 15 Hz) could be observed but not in isoflurane anesthetized rats. We propose that anesthetics affect the glymphatic pathway transport not simply by inducing unconsciousness but also by additional mechanisms, one of which is the repression of norepinephrine release.

  6. Recoil implantation of boron into silicon by high energy silicon ions

    Science.gov (United States)

    Shao, L.; Lu, X. M.; Wang, X. M.; Rusakova, I.; Mount, G.; Zhang, L. H.; Liu, J. R.; Chu, Wei-Kan

    2001-07-01

    A recoil implantation technique for shallow junction formation was investigated. After e-gun deposition of a B layer onto Si, 10, 50, or 500 keV Si ion beams were used to introduce surface deposited B atoms into Si by knock-on. It has been shown that recoil implantation with high energy incident ions like 500 keV produces a shallower B profile than lower energy implantation such as 10 keV and 50 keV. This is due to the fact that recoil probability at a given angle is a strong function of the energy of the primary projectile. Boron diffusion was showed to be suppressed in high energy recoil implantation and such suppression became more obvious at higher Si doses. It was suggested that vacancy rich region due to defect imbalance plays the role to suppress B diffusion. Sub-100 nm junction can be formed by this technique with the advantage of high throughput of high energy implanters.

  7. Tribological properties of nitrogen implanted and boron implanted steels

    International Nuclear Information System (INIS)

    Kern, K.T.

    1996-01-01

    Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented

  8. Permanent I-125 interstitial implant in the management of high grade CNS malignancies in children

    International Nuclear Information System (INIS)

    Vaishampayan, N.; Zamorano, L.; Aronin, P.; Gaspar, L.; Canady, A.; Lattin, P.; Ezzell, G.; Yakar, D.; Chungbin, S.; Fontanesi, J.

    1996-01-01

    Purpose/Objective: To evaluate the efficacy and complications associated with the use of permanent I-125 interstitial implants in children with high grade CNS malignancies. Materials and Methods: Between May of 1990 and September of 1994, fourteen children received permanent I-125 interstitial implant brachytherapy as initial therapy (n=8) or at time of recurrence (n=6). Histologies included Glioblastoma Multiforme (n=2), Anaplastic Astrocytoma (n=9) and others (n=3). Pre-implant surgical procedures included: Gross Total Resection (n=2), Subtotal Resection (n=8) or Biopsy alone (n=4). Six patients received pre-implant external beam irradiation (dose range 3,500-6500 cGy) and three patients received post-implant external beam irradiation (dose range 5,040-5,060 cGy). Implant dose range was 8,294-10,368 cGy over the lifetime of the implant (median 10,368 cGy). Results: At last follow-up (median 17.5 months; range 4-56 months), eight children were alive. Six out of the eight had no evidence of disease progression while the remaining had radiologic evidence of progression. Implant complications (n=2) included skin necrosis and bone flap infection. Conclusions: Based on this initial review, we continue to investigate the use of permanent I-125 interstitial brachytherapy in the treatment of high grade CNS malignancies in children and will discuss and compare these results with those of other 'Boost' series

  9. Biochemical parameters of pregnant rats and their offspring exposed to different doses of inorganic mercury in drinking water.

    Science.gov (United States)

    Oliveira, Cláudia S; Oliveira, Vitor A; Ineu, Rafael P; Moraes-Silva, Lucélia; Pereira, Maria E

    2012-07-01

    This work investigated the effects of low and high doses of inorganic mercury in drinking water on biochemical parameters of pregnant rats and their offspring. Female Wistar rats were treated during pregnancy with 0, 0.2, 0.5, 10 or 50 μg Hg(2+)/mL as HgCl(2). Rats were euthanized on day 20 of pregnancy. Pregnant rats presented a decrease in total water intake in all doses of mercury tested. At high doses, a decrease in the total food intake and in body weight gain was observed. Pregnant rats exposed to 50 μg Hg(2+)/mL presented an increase in kidney relative weight. Mercury exposure did not change serum urea and creatinine levels in any of the doses tested. Moreover, mercury exposure did not change porphobilinogen synthase activity of kidney, liver and placenta from pregnant rats in any of the doses tested, whereas fetuses of pregnant rats exposed to 50 μg Hg(2+)/mL presented an increase in the hepatic porphobilinogen synthase activity. In general, pregnant rats presented alterations due to HgCl(2) exposure in drinking water. However, only the dose 50 μg Hg(2+)/mL appeared to be enough to cross the blood-placenta barrier, since at this dose the fetuses presented change in the porphobilinogen synthase activity. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Effect of alpha-lipoic acid on endometrial implants in an experimental rat model.

    Science.gov (United States)

    Pınar, Neslihan; Soylu Karapınar, Oya; Özcan, Oğuzhan; Özgür, Tümay; Bayraktar, Suphi

    2017-10-01

    To investigate the antioxidant and anti-inflammatory effects of alpha-lipoic acid (ALA) in the treatment of endometriosis in an experimental rat model by evaluating biochemical and histopathologic parameters. Experimental endometriosis was induced by the peritoneal implantation of autologous endometrial tissue. The rats were randomly divided into two groups with eight rats each. Group I was intraperitoneally administered ALA 100 mg/kg/day for 14 days. Group II was intraperitoneally administered saline solution at the same dosage and over the same period. Endometrial implant volume was measured in both groups both pre- and post-treatment. Tumor necrosis factor alpha (TNF-α) was measured in peritoneal fluid. Total antioxidant status (TAS), total oxidant status (TOS), and oxidative stress index (OSI) were assessed in serum. The implants were histopathologically evaluated. In the ALA group, the serum TOS and OSI levels, the endometrial implant volumes, the TNF-α levels in serum and peritoneal fluid, and the histopathologic scores were significantly lower compared to the control group (P < 0.05). Alpha-lipoic acid may have a therapeutic potential in the treatment of endometriosis due to its antioxidant and anti-inflammatory effects. © 2017 Société Française de Pharmacologie et de Thérapeutique.

  11. Studies on implantation of 198Au-grain as a radiation therapy to cancer tissue

    International Nuclear Information System (INIS)

    Machida, Seiro

    1975-01-01

    The most effective dose of 198 Au-grain to be implanted and the clinicopathological findings after treatment are discussed. A safe dose of 198 Au-grain which could be implanted subcutaneously in rats, was under 2 mCi migration of 198 Au-grain was not recognized. In Yoshida sarcoma, transplanted subcutaneously into the backs of rats the most effective dose of 198 Au-grain was 2mCi/g of tumour tissue. However, about half of the rats implanted with this dosage died from the growing tumour. Histological examination of the implanted tumour tissue, revealed necrosis within a distance of only 0.4 mm from 198 Au-grain particles. In small metastatic tumours after 198 Au-grain implantation, there was necrosis i.e. pyknosis and karyolysis of the tumour cells, fibrosis and hyaline degeneration of the stroma. However, hardly any change in tumour size was detectable because of swelling and induration around the tumour. In some of the cases treated with 198 Au-grain combined with 60 Co or with chemotherapeutics, the tumour size was evidently reduced and became non-palable. Side effects were minimal except in one case which was afflicted temporarily with radiation sickness after an implantation of 200 mCi 198 Au-grain. In conclusion, the implantation of 198 Au-grain into the tumour was found to be very safe for the patients with surgically incurable cancer. Because of the short range of 198 Au-grain radioactivity, homogeneous density of 198 Au-grain into the whole tumour tissue is required. A combination with other radiations and/or with chemotherapeutics is also recommended. (author)

  12. Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Wei, E-mail: wei.luo@uky.edu; Molloy, Janelle; Aryal, Prakash; Feddock, Jonathan; Randall, Marcus [Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky 40536 (United States)

    2014-02-15

    Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F

  13. Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

    International Nuclear Information System (INIS)

    Luo, Wei; Molloy, Janelle; Aryal, Prakash; Feddock, Jonathan; Randall, Marcus

    2014-01-01

    Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F r : with resensitization, F n : without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F r ) and without (F n ) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F r /F n were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F r /F n were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F r /F n were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F r was 1.07/1.11 (rounded to 1.1), and the averaged value of F n was 1.75/1.18. F r of 1.1 has been applied to

  14. Positron annihilation studies of high dose Sb implanted silicon

    International Nuclear Information System (INIS)

    Schut, H.; Eijt, S.W.H.; Beling, C.D.; Ho, K.; Takamura, Y.

    2005-01-01

    The formation and evolution of vacancies and precipitates created by implantation of 60 keV, 2 x 10 16 cm -2 Sb + in pre-amorphized (0 0 1) Cz-Si is studied using the Doppler broadening (DB) and two-dimensional angular correlation of annihilation radiation (2D-ACAR) positron beam techniques. After implantation, samples were laser annealed (LTA) and subsequently thermal annealed at temperatures ranging from 400 to 1000 deg. C. Implantation-induced vacancy-type defects were detected up to a depth of 280 nm. After LTA, positron annihilation related to both Sb and remaining defects is observed in the first 100 nm below the surface. The deeper region only shows positron trapping at vacancy-type defects with strong reduced concentration. Complete removal is obtained after 600 deg. C anneal. At this temperature, the positron data for the upper region reveals trapping at Sb and Si sites only. With increasing annealing time (at 600 deg. C) or increasing temperature (up to 1000 deg. C) positron annihilation at Sb-sites associated with neighboring vacancies becomes apparent. Results are correlated with the observed Sb electrical deactivation above 600 deg. C, the shift from small Sb aggregates to precipitates and out-diffusion of Sb from the implantation region at higher temperatures

  15. A comparative study of zinc, magnesium, strontium-incorporated hydroxyapatite-coated titanium implants for osseointegration of osteopenic rats

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Zhou-Shan [Department of Orthopaedic Surgery, Second Affiliated Hospital of Wenzhou Medical University, 109 Xueyuan Xi Road, Wenzhou, Zhejiang 325027 (China); Zhou, Wan-Shu [Endocrine & Metabolic Diseases Unit, Affiliated Hospital of Guizhou Medical University, Guizhou 550001 (China); He, Xing-Wen [Department of Orthopaedic Surgery, Hangzhou Bay Hospital of Ningbo, 315000 (China); Liu, Wei [Department of Orthopaedic Surgery, Jingmen No. 1 People' s Hospital, Jingmen 44800, Hubei (China); Bai, Bing-Li; Zhou, Qiang; Huang, Zheng-Liang; Tu, Kai-kai; Li, Hang; Sun, Tao [Department of Orthopaedic Surgery, Second Affiliated Hospital of Wenzhou Medical University, 109 Xueyuan Xi Road, Wenzhou, Zhejiang 325027 (China); Lv, Yang-Xun [Department of Orthopaedic Surgery, Wenzhou Central Hospital, Wenzhou, Zhejiang 325000 (China); Cui, Wei [Sichuan Provincial Orthopedics Hospital, No. 132 West First Section First Ring Road, Chengdu, Sichuan 610000 (China); Yang, Lei, E-mail: tzs19900327@163.com [Department of Orthopaedic Surgery, Second Affiliated Hospital of Wenzhou Medical University, 109 Xueyuan Xi Road, Wenzhou, Zhejiang 325027 (China)

    2016-05-01

    Surface modification techniques have been applied to generate titanium implant surfaces that promote osseointegration for the implants in cementless arthroplasty. However, its effect is not sufficient for osteoporotic bone. Zinc (Zn), magnesium (Mg), and strontium (Sr) present a beneficial effect on bone growth, and positively affect bone regeneration. The aim of this study was to confirm the different effects of the fixation strength of Zn, Mg, Sr-substituted hydroxyapatite-coated (Zn-HA-coated, Mg-HA-coated, Sr-HA-coated) titanium implants via electrochemical deposition in the osteoporotic condition. Female Sprague–Dawley rats were used for this study. Twelve weeks after bilateral ovariectomy, all animals were randomly divided into four groups: group HA; group Zn-HA; group Mg-HA and group Sr-HA. Afterwards, all rats from groups HA, Zn-HA, Mg-HA and Sr-HA received implants with hydroxyapatite containing 0%, 10% Zn ions, 10% Mg ions, and 10% Sr ions. Implants were inserted bilaterally in all animals until death at 12 weeks. The bilateral femurs of rats were harvested for evaluation. All treatment groups increased new bone formation around the surface of titanium rods and push-out force; group Sr-HA showed the strongest effects on new bone formation and biomechanical strength. Additionally, there are significant differences in bone formation and push-out force was observed between groups Zn-HA and Mg-HA. This finding suggests that Zn, Mg, Sr-substituted hydroxyapatite coatings can improve implant osseointegration, and the 10% Sr coating exhibited the best properties for implant osseointegration among the tested coatings in osteoporosis rats. - Highlights: • Surface modification techniques have been applied to generate titanium implant surfaces that promote osseointegration for the implants in cementless arthroplasty. • However, its effect is not sufficient for osteoporotic bone. Zinc (Zn), Magnesium(Mg), Strontium (Sr) present a benificial effect on bone

  16. Comparison of metal concentrations in rat tibia tissues with various metallic implants.

    Science.gov (United States)

    Okazaki, Yoshimitsu; Gotoh, Emiko; Manabe, Takeshi; Kobayashi, Kihei

    2004-12-01

    To compare metal concentrations in tibia tissues with various metallic implants, SUS316L stainless steel, Co-Cr-Mo casting alloy, and Ti-6Al-4V and V-free Ti-15Zr-4Nb-4Ta alloys were implanted into the rat tibia for up to 48 weeks. After the implant was removed from the tibia by decalcification, the tibia tissues near the implant were lyophilized. Then the concentrations of metals in the tibia tissues by microwave acid digestion were determined by inductively coupled plasma-mass spectrometry. Fe concentrations were determined by graphite-furnace atomic absorption spectrometry. The Fe concentration in the tibia tissues with the SUS316L implant was relatively high, and it rapidly increased up to 12 weeks and then decreased thereafter. On the other hand, the Co concentration in the tibia tissues with the Co-Cr-Mo implant was lower, and it increased up to 24 weeks and slightly decreased at 48 weeks. The Ni concentration in the tibia tissues with the SUS316L implant increased up to 6 weeks and then gradually decreased thereafter. The Cr concentration tended to be higher than the Co concentration. This Cr concentration linearly increased up to 12 weeks and then decreased toward 48 weeks in the tibia tissues with the SUS316L or Co-Cr-Mo implant. Minute quantities of Ti, Al and V in the tibia tissues with the Ti-6Al-4V implant were found. The Ti concentration in the tibia tissues with the Ti-15Zr-4Nb-4Ta implant was lower than that in the tibia tissues with the Ti-6Al-4V implant. The Zr, Nb and Ta concentrations were also very low. The Ti-15Zr-4Nb-4Ta alloy with its low metal release in vivo is considered advantageous for long-term implants.

  17. Optimum timing for image-based dose evaluation of 125I and 103Pd prostate seed implants

    International Nuclear Information System (INIS)

    Yue Ning; Chen Zhe; Peschel, Richard; Dicker, Adam P.; Waterman, Frank M.; Nath, Ravinder

    1999-01-01

    Purpose/Objective: Image-based dose evaluation of permanent brachytherapy implants for prostate cancer is important for optimal patient management after implantation. Because of edema caused by the surgical procedure in the implantation, if the dose evaluation is based on the images obtained too early after implantation, dose coverage will usually be underestimated. Conversely, if the images are obtained too late, the dose coverage will be overestimated. This study uses a biomathematical model to simulate edema and its resolution on 29 patients, so that the optimum time to obtain image scans and perform dose evaluation can be investigated and estimated. Methods and Materials: Edema of a prostate and its resolution has been shown to follow an exponential function V(t) = V(0)(1 + ΔV[e -0.693t/Te - 1]) where ΔV is the initial relative increase in the prostate volume due to edema (and is related to edema magnitude), and T e (edema half-life) is the time for the edema to decrease by half in volume. In this study, edema was simulated by increasing the volume of preimplant prostate (obtained from ultrasound volume study) to a given magnitude of edema. Similarly, the locations of planned seeds were changed to their corresponding locations in the edematous prostate proportionally. The edema was then allowed to resolve according to the exponential function. The correct dose distribution was calculated by taking into account the dynamic variations of the prostate volume, seed locations, and source strengths with respect to time. Dose volume histograms (DVHs) were then generated from this dose distribution. The conventional postimplant DVHs, which assume the prostate volume and seed locations are as in the image scans and constant in time, were also calculated based on the simulated image scans for various days postimplantation. The conventional DVHs of prostate on various days after implantation were compared to the DVH calculated assuming dynamic conditions. The optimum

  18. Serum metabonomics of rats irradiated by low-dose γ-rays

    Directory of Open Access Journals (Sweden)

    Ying HE

    2014-08-01

    Full Text Available Objective To explore the effect of low-dose γ-rays on the metabolites in rat serum. Methods Sixteen healthy male SD rats were randomly divided into control group and irradiated group (n=8. The rats in irradiated group were irradiated by 60Co γ-rays with a dose rate of 72mGy/h for 7 days (1 hour per day. At the 7th day after irradiation, blood samples were taken from abdominal aorta to obtain the serum. The metabolic fingerprints of serum were obtained from the two groups of rats, and 1H nuclear magnetic resonance (NMR spectroscopy, principal component analysis (PCA and orthogonal signal correction-partial least squares (OSC-PLS method were used for pattern recognition, and the difference in metabolite profile between two groups was identified by SIMCA-P software. Results The rat serum 1H NMR spectra revealed a significant difference between control group and irradiated group, the OSC-PLS plots of the serum samples presented marked clustering between two groups. Compared with the control group, the content of lipid, glucose, creatine, glycine/glucose, high density lipoprotein, low density lipoprotein, very low density lipoprotein/low density lipoprotein and unsaturated fatty acid increased, while the content of lactic acid, threonine/lipid, alanine, N-acetyl glycoprotein 1, N-acetyl glycoprotein 2, saturated fatty acid and phosphatidyl choline decreased in irradiated group. Conclusion Irradiation with low-dose γ-ray could induce changes in metabolites in rat serum, concerning mainly immune function, energy metabolism, carbohydrate metabolism and lipid metabolism. DOI: 10.11855/j.issn.0577-7402.2014.07.02

  19. Dexamethasone hepatic induction in rats subsequently treated with high dose buprenorphine does not lead to respiratory depression

    International Nuclear Information System (INIS)

    Hreiche, Raymond; Megarbane, Bruno; Pirnay, Stephane; Borron, Stephen W.; Monier, Claire; Risede, Patricia; Milan, Nathalie; Descatoire, Veronique; Pessayre, Dominique; Baud, Frederic J.

    2006-01-01

    In humans, asphyxic deaths and severe poisonings have been attributed to high-dosage buprenorphine, a maintenance therapy for heroin addiction. However, in rats, intravenous buprenorphine at doses up to 90 mg kg -1 was not associated with significant effects on arterial blood gases. In contrast, norbuprenorphine, the buprenorphine major cytochrome P450 (CYP) 3A-derived metabolite, is a potent respiratory depressant. Thus, our aim was to study the consequences of CYP3A induction on buprenorphine-associated effects on resting ventilation in rats. We investigated the effects on ventilation of 30 mg kg -1 buprenorphine alone or following cytochrome P450 (CYP) 3A induction with dexamethasone, using whole body plethysmography (N = 24) and arterial blood gases (N = 12). Randomized animals in 4 groups received sequential intraperitoneal dosing with: (dexamethasone [days 1-3] + buprenorphine [day 4]), (dexamethasone solvent [days 1-3] + buprenorphine [day 4]), (dexamethasone [days 1-3] + buprenorphine solvent [day 4]), or (dexamethasone solvent [days 1-3] + buprenorphine solvent [day 4]). Buprenorphine alone caused a significant rapid and sustained increase in the inspiratory time (P -1 buprenorphine on rat ventilation. Our results suggest a limited role of drug-mediated CYP3A induction in the occurrence of buprenorphine-attributed respiratory depression in addicts

  20. Development of a high current ion implanter

    International Nuclear Information System (INIS)

    Choi, Byung Ho; Kim, Wan; Jin, Jeong Tae

    1990-01-01

    A high current ion implanter of the energy of 100 Kev and the current of about 100 mA has been developed for using the high dose ion implantation, surface modification of steels and ceramics, and ion beam milling. The characteristics of the beam extraction and transportation are investigated. A duoPIGatron ion source compatible with gas ion extraction of about 100 mA, a single gap acceleration tube which is able to compensate the divergence due to the space charge effect, and a beam transport system with the concept of the space charge neutralization are developed for the high current machine. The performance of the constructed machine shows that nitrogen, argon, helium, hydrogen and oxygen ion beams are successfully extracted and transported at a beam divergence due to space charge effect is negligible in the operation pressure of 2 x 10 -5 torr. (author)

  1. Screening of high-yield GTF yeast by N+-implantation

    International Nuclear Information System (INIS)

    Gao Yanhong; Lv Jiaping; Liu Lu; Li Shurong

    2009-01-01

    In this study, one of the highest chromium-resistant strain was screened from 12 tested brewer's yeast. N + ion implantation was used to mutate this yeast and screened high-yield GTF yeast strains with Chromium tolerance method. The mutagenesis was conducted by 50 KeV N + ion implantation with the doses of 1 x 2.6 x 10 13 , 2 x 2.6 x 10 13 , 3 x 2.6 x 10 13 , 4 x 2.6 x 10 13 , 5 x 2.6 x 10 13 and 6 x 2.6 x 10 13 ion/cm 2 . Results showed that the optimum dose was 4 x 2.6 x 10 13 ion/cm 2 , and a strain M11-1A11 of high-producing GTF was obtained. Its organic Cr content was increased by 22.4% than the original strain. Its fermentation property was stable after 5 generation transfer inoculation. (authors)

  2. Freezing of Rat Tibiae at -20°C Does Not Affect the Mechanical Properties of Intramedullary Bone/Implant-Interface: Brief Report

    Science.gov (United States)

    Diefenbeck, Michael; Mückley, Thomas; Zankovych, Sergiy; Bossert, Jörg; Jandt, Klaus D; Schrader, Christian; Schmidt, Jürgen; Finger, Ulrich; Faucon, Mathilde

    2011-01-01

    Background: The effects of freezing-thawing cycles on intramedullary bone-implant interfaces have been studied in a rat model in mechanical pull-out tests. Implants: Twenty TiAl6V4 rods (Ø 0.8 mm, length 10 mm) implanted in rat tibiae Methods: 10 rats underwent bilateral tibial implantation of titanium rods. At eight weeks, the animals were sacrificed and tibiae harvested for biomechanical testing. Eight tibiae were frozen and stored at -20°C for 14 days, the remaining eight were evaluated immediately post-harvest. Pull-out tests were used to determine maximum force and interfacial shear strength. Results: There were no significant differences between fresh and those of the frozen-thawed group in maximum force or in interfacial shear strength. Conclusion: Frozen Storage of rat tibiae containing implants at -20° C has no effects on the biomechanical properties of Bone/ Implant interface. PMID:21760868

  3. Effect of implanted doses of N+-ions on the contact resistance of copper contacts

    International Nuclear Information System (INIS)

    Dubravec, B.; Kovac, P.; Lipka, F.; Padysak, M.

    1997-01-01

    The paper deals with the effect of implanted doses of N + ions on the contact resistance. Dependencies of the contact resistance versus contact force R c =f(F c ) and microhardness of implanted surfaces were measured for three implanted profiles. The influence of the aggressive environs on the contact resistance of implanted contact is given too

  4. In vivo dosimetry using a linear Mosfet-array dosimeter to determine the urethra dose in 125I permanent prostate implants.

    Science.gov (United States)

    Bloemen-van Gurp, Esther J; Murrer, Lars H P; Haanstra, Björk K C; van Gils, Francis C J M; Dekker, Andre L A J; Mijnheer, Ben J; Lambin, Philippe

    2009-01-01

    In vivo dosimetry during brachytherapy of the prostate with (125)I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% +/- 10.7% (1 SD). In the low-dose region outside the prostate (MOSFET detectors are suitable for in vivo dosimetry during (125)I brachytherapy of prostate cancer. An action level of +/- 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

  5. Independent technique of verifying high-dose rate (HDR) brachytherapy treatment plans

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Korb, Leroy J.; Darnell, Brenda; Krishna, K. V.; Ulewicz, Dennis

    1998-01-01

    Purpose: An independent technique for verifying high-dose rate (HDR) brachytherapy treatment plans has been formulated and validated clinically. Methods and Materials: In HDR brachytherapy, dwell times at respective dwell positions are computed, using an optimization algorithm in a HDR treatment-planning system to deliver a specified dose to many target points simultaneously. Because of the variability of dwell times, concerns have been expressed regarding the ability of the algorithm to compute the correct dose. To address this concern, a commercially available low-dose rate (LDR) algorithm was used to compute the doses at defined distances, based on the dwell times obtained from the HDR treatment plans. The percent deviation between doses computed using the HDR and LDR algorithms were reviewed for HDR procedures performed over the last year. Results: In this retrospective study, the difference between computed doses using the HDR and LDR algorithms was found to be within 5% for about 80% of the HDR procedures. All of the reviewed procedures have dose differences of less than 10%. Conclusion: An independent technique for verifying HDR brachytherapy treatment plans has been validated based on clinical data. Provided both systems are available, this technique is universal in its applications and not limited to either a particular implant applicator, implant site, or implant type

  6. Inhibitory Effect of High Dose of the Flavonoid Quercetin on Amygdala Electrical Kindling in Rats

    Directory of Open Access Journals (Sweden)

    Tourandokht Baluchnejadmojarad

    2010-05-01

    Full Text Available A B S T R A C T Introduction: Epilepsy is a chronic neurological disorder in which patients experience spontaneous recurrent seizures. Although the most commonly recommended therapy is drug treatment, some patients do not achieve adequate control of their seizures on existing drugs. New medications with novel mechanisms of action are needed to help those patients whose seizures are resistant to currently-available drugs. Therefore, the anti-convulsant effect of a high dose of quercetin was evaluated in amygdala kindling model in male rats. Methods: Rats were divided into sham-operated group, quercetintreated SH, kindled, and quercetin-treated kindled rats. Quercetin was administered i.p. one day before amygdale kindling for 3 weeks (40 mg/kg/day. The parameters seizure stage, AD duration, the latency to the onset of stage 4, and the duration of stage 5 were analyzed. Results: The results showed that quercetin pretreatment causes a lower seizure intensity in treated kindled rats (p<0.05-0.01, a lower after-discharge duration (p<0.05-0.01, and a higher latency to stage IV (p<0.05 as compared to untreated kindled ones. Discussion: To conclude, chronic administration of quercetin inhibits amygdala electrical kindling and more studies are warranted to clarify its underlying mechanisms.

  7. Dose-response characteristics of methylphenidate on locomotor behavior and on sensory evoked potentials recorded from the VTA, NAc, and PFC in freely behaving rats

    Directory of Open Access Journals (Sweden)

    Swann Alan C

    2006-01-01

    Full Text Available Abstract Background Methylphenidate (MPD is a psychostimulant commonly prescribed for attention deficit/hyperactivity disorder. The mode of action of the brain circuitry responsible for initiating the animals' behavior in response to psychostimulants is not well understood. There is some evidence that psychostimulants activate the ventral tegmental area (VTA, nucleus accumbens (NAc, and prefrontal cortex (PFC. Methods The present study was designed to investigate the acute dose-response of MPD (0.6, 2.5, and 10.0 mg/kg on locomotor behavior and sensory evoked potentials recorded from the VTA, NAc, and PFC in freely behaving rats previously implanted with permanent electrodes. For locomotor behavior, adult male Wistar-Kyoto (WKY; n = 39 rats were given saline on experimental day 1 and either saline or an acute injection of MPD (0.6, 2.5, or 10.0 mg/kg, i.p. on experimental day 2. Locomotor activity was recorded for 2-h post injection on both days using an automated, computerized activity monitoring system. Electrophysiological recordings were also performed in the adult male WKY rats (n = 10. Five to seven days after the rats had recovered from the implantation of electrodes, each rat was placed in a sound-insulated, electrophysiological test chamber where its sensory evoked field potentials were recorded before and after saline and 0.6, 2.5, and 10.0 mg/kg MPD injection. Time interval between injections was 90 min. Results Results showed an increase in locomotion with dose-response characteristics, while a dose-response decrease in amplitude of the components of sensory evoked field responses of the VTA, NAc, and PFC neurons. For example, the P3 component of the sensory evoked field response of the VTA decreased by 19.8% ± 7.4% from baseline after treatment of 0.6 mg/kg MPD, 37.8% ± 5.9% after 2.5 mg/kg MPD, and 56.5% ± 3.9% after 10 mg/kg MPD. Greater attenuation from baseline was observed in the NAc and PFC. Differences in the intensity of

  8. Effect of implantation of biodegradable magnesium alloy on BMP-2 expression in bone of ovariectomized osteoporosis rats

    International Nuclear Information System (INIS)

    Guo, Yue; Ren, Ling; Liu, Chang; Yuan, Yajiang; Lin, Xiao; Tan, Lili; Chen, Shurui; Yang, Ke; Mei, Xifan

    2013-01-01

    The study was focused on the implantation of a biodegradable AZ31 magnesium alloy into the femoral periosteal of the osteoporosis modeled rats. The experimental results showed that after 4 weeks implantation of AZ31 alloy in the osteoporosis modeled rats, the expression of BMP-2 in bone tissues of the rats was much enhanced, even higher than the control group, which should promote the bone formation and be beneficial for reducing the harmful effect of osteoporosis. Results of HE stains showed that the implantation of AZ31 alloy did not have obvious pathological changes on both the liver and kidney of the animal. - Highlights: • Mg alloy greatly increased expression of BMP-2 in osteoporosis modeled rat bone. • Mg alloy showed good biological safety. • Mg alloy is beneficial for reducing the symptom of osteoporosis

  9. Monte Carlo-based dose reconstruction in a rat model for scattered ionizing radiation investigations.

    Science.gov (United States)

    Kirkby, Charles; Ghasroddashti, Esmaeel; Kovalchuk, Anna; Kolb, Bryan; Kovalchuk, Olga

    2013-09-01

    In radiation biology, rats are often irradiated, but the precise dose distributions are often lacking, particularly in areas that receive scatter radiation. We used a non-dedicated set of resources to calculate detailed dose distributions, including doses to peripheral organs well outside of the primary field, in common rat exposure settings. We conducted a detailed dose reconstruction in a rat through an analog to the conventional human treatment planning process. The process consisted of: (i) Characterizing source properties of an X-ray irradiator system, (ii) acquiring a computed tomography (CT) scan of a rat model, and (iii) using a Monte Carlo (MC) dose calculation engine to generate the dose distribution within the rat model. We considered cranial and liver irradiation scenarios where the rest of the body was protected by a lead shield. Organs of interest were the brain, liver and gonads. The study also included paired scenarios where the dose to adjacent, shielded rats was determined as a potential control for analysis of bystander effects. We established the precise doses and dose distributions delivered to the peripheral organs in single and paired rats. Mean doses to non-targeted organs in irradiated rats ranged from 0.03-0.1% of the reference platform dose. Mean doses to the adjacent rat peripheral organs were consistent to within 10% those of the directly irradiated rat. This work provided details of dose distributions in rat models under common irradiation conditions and established an effective scenario for delivering only scattered radiation consistent with that in a directly irradiated rat.

  10. Monitoring of implanted stem cell migration in vivo: A highly resolved in vivo magnetic resonance imaging investigation of experimental stroke in rat

    Science.gov (United States)

    Hoehn, Mathias; Küstermann, Ekkehard; Blunk, James; Wiedermann, Dirk; Trapp, Thorsten; Wecker, Stefan; Föcking, Melanie; Arnold, Heinz; Hescheler, Jürgen; Fleischmann, Bernd K.; Schwindt, Wolfram; Bührle, Christian

    2002-01-01

    In vivo monitoring of stem cells after grafting is essential for a better understanding of their migrational dynamics and differentiation processes and of their regeneration potential. Migration of endogenous or grafted stem cells and neurons has been described in vertebrate brain, both under normal conditions from the subventricular zone along the rostral migratory stream and under pathophysiological conditions, such as degeneration or focal cerebral ischemia. Those studies, however, relied on invasive analysis of brain sections in combination with appropriate staining techniques. Here, we demonstrate the observation of cell migration under in vivo conditions, allowing the monitoring of the cell dynamics within individual animals, and for a prolonged time. Embryonic stem (ES) cells, constitutively expressing the GFP, were labeled by a lipofection procedure with a MRI contrast agent and implanted into rat brains. Focal cerebral ischemia had been induced 2 weeks before implantation of ES cells into the healthy, contralateral hemisphere. MRI at 78-μm isotropic spatial resolution permitted the observation of the implanted cells with high contrast against the host tissue, and was confirmed by GFP registration. During 3 weeks, cells migrated along the corpus callosum to the ventricular walls, and massively populated the borderzone of the damaged brain tissue on the hemisphere opposite to the implantation sites. Our results indicate that ES cells have high migrational dynamics, targeted to the cerebral lesion area. The imaging approach is ideally suited for the noninvasive observation of cell migration, engraftment, and morphological differentiation at high spatial and temporal resolution. PMID:12444255

  11. Estimation of the transit dose component in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Garcia Romero, A.; Millan Cebrian, E.; Lozano Flores, F.J.; Lope Lope, R.; Canellas Anoz, M.

    2001-01-01

    Current high dose rate brachytherapy (HDR) treatment planning systems usually calculate dose only from source stopping positions (stationary component), but fails to account for the administered dose when the source is moving (dynamic component or transit dose). Numerical values of this transit dose depends upon the source velocity, implant geometry, source activity and prescribed dose. In some HDR treatments using particular geometry the transit dose cannot be ignored because it increases the dose at the prescriptions points and also could increase potential late tissue complications as predicted by the linear quadratic model. International protocols recommend to verify this parameter. The aim of this paper has been to establish a procedure for the transit dose calculation for the Gammamed 12i equipment at the RT Department in the Clinical University Hospital (Zaragoza-Spain). A numeric algorithm was implemented based on a dynamic point approximation for the moving HDR source and the calculated results for the entrance-exit transit dose was compared with TLD measurements made in some discrete points. (author) [es

  12. CONTRASTING DOSE-RATE EFFECTS OF GAMMA-IRRADIATION ON RAT SALIVARY-GLAND FUNCTION

    NARCIS (Netherlands)

    VISSINK, A; DOWN, JD; KONINGS, AWT

    The aim of this study was to investigate the effects of Co-60 irradiation delivered at high (HDR) and low (LDR) dose-rates on rat salivary gland function. Total-body irradiation (TBI; total doses 7.5, 10 and 12.5 Gy) was applied from a Co-60 source at dose-rates of 1 cGy/min (LDR) and 40 cGy/min

  13. High dislocation density structures and hardening produced by high fluency pulsed-ion-beam implantation

    International Nuclear Information System (INIS)

    Sharkeev, Yu.P.; Didenko, A.N.; Kozlov, E.V.

    1994-01-01

    The paper presents a review of experimental data on the ''long-range effect'' (a change in dislocation structure and in physicomechanical properties at distances considerably greater than the ion range value in ion-implanted metallic materials and semiconductors). Our results of electron microscopy studies of high density dislocation structure in ion-implanted metallic materials with different initial states are given. It has been shown that the nature of the dislocation structure and its quantitative characteristics in the implanted metals and alloys depend on the target initial state, the ion type and energy and the retained dose. The data obtained by different workers are in good agreement both with our results and with each other as well as with the results of investigation of macroscopic characteristics (wear resistance and microhardness). It has been established that the ''long-range effect'' occurs in metallic materials with a low yield point or high plasticity level and with little dislocation density in their initial state prior to ion implantation. ((orig.))

  14. Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant

    International Nuclear Information System (INIS)

    Afsharpour, Hossein; Beaulieu, Luc; Pignol, Jean-Philippe; Keller, Brian; Carrier, Jean-Francois; Reniers, Brigitte; Verhaegen, Frank

    2010-01-01

    The impact of tissue heterogeneity and interseed attenuation is studied in post-implant evaluation of five clinical permanent breast 103 Pd seed implants using the Monte Carlo (MC) dose calculation method. Dose metrics for the target (PTV) as well as an organ at risk (skin) are used to visualize the differences between a TG43-like MC method and more accurate MC methods capable of considering the breast tissue heterogeneity as well as the interseed attenuation. PTV dose is reduced when using a breast tissue model instead of water in MC calculations while the dose to the skin is increased. Furthermore, we investigate the effect of varying the glandular/adipose proportion of the breast tissue on dose distributions. The dose to the PTV (skin) decreases (increases) with the increasing adipose proportion inside the breast. In a complete geometry and compared to a TG43-like situation, the average PTV D 90 reduction varies from 3.9% in a glandular breast to 35.5% when the breast consists entirely of adipose. The skin D 10 increases by 28.2% in an entirely adipose breast. The results of this work show the importance of an accurate and patient-dependent breast tissue model to be used in the dosimetry for this kind of low energy implant.

  15. Wheat aleurone polyphenols increase plasma eicosapentaenoic acid in rats

    Directory of Open Access Journals (Sweden)

    Fayçal Ounnas

    2014-08-01

    Full Text Available Methods: These studies were designed to assess whether wheat polyphenols (mainly ferulic acid [FA] increased the very-long-chain omega-3 fatty acids (VLC n-3 [eicosapentaenoic acid (EPA and docosahexaenoic acid (DHA] in rats. Wheat aleurone (WA was used as a dietary source of wheat polyphenols. Two experiments were performed; in the first one, the rats were fed WA or control pellets (CP in presence of linseed oil (LO to provide alpha-linolenic acid (ALA, the precursor of VLC n-3. In the second one, the rats were fed WA or CP in presence of control oil (CO without ALA. The concentrations of phenolic acid metabolites in urine were also investigated. Results: The urinary concentration of conjugated FA increased with WA ingestion (p<0.05. Plasma EPA increased by 25% (p<0.05 with WA in the CO group but not in the LO group. In contrast, there was no effect of WA on plasma DHA and omega-6 fatty acids (n-6. Finally, both n-3 and n-6 in the liver remained unchanged by the WA. Conclusion: These results suggest that WA consumption has a significant effect on EPA in plasma without affecting n-6. Subsequent studies are required to examine whether these effects may explain partly the health benefits associated with whole wheat consumption.

  16. Evaluation of porous vitreous carbon or silicon implants by radiology in rat's skull; Avaliacao radiologica de implantes de carbono vitreo poroso ou silicone em cranio de ratos

    Energy Technology Data Exchange (ETDEWEB)

    Vaccari-Mazzetti, Marcelo Paulo; Kobata, Celio Toshiro [Lusiada University of Santos, SP (Brazil). Hospital Defeitos da Face. Dept. of Surgery]. E-mail: mmgvaccari@ig.com.br; Fabiani, Paulo [Lusiada University of Santos, SP (Brazil). Dept. of Radiology; Martins, Dulce Maria Fonseca Soares [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Surgery. Div. of Plastic Surgery; Gomes, Paulo de Oliveira [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Surgery. Div. of Operatory Technique and Experimental Surgery; Martins, Jose Luiz [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. of Surgery. Div. of Pediatric Surgery

    2008-07-01

    Purpose: Evaluate by CT the use of porous vitreous carbon (PVC) and silicon (S) implants as the replacement bone in the craniofacial skeleton of rats. Methods: 40 rats divided in: Group A (n=20) PVC submitted to the implant of a fragment in skull. After the euthanasia, the animals were divided into two subgroups: A I: 10 animals, studied in the 7th postoperative day (P.O) and AII: 10 animals, studied in the 28th P.O. In group B, S, 20 rats were submitted to S implant in the skull. All other steps were identical to group A, with designation of subgroups BI and BII. CT with beams in axial cuts of 1 mm thickness to obtain 3-D information It was used Hounsfield scale for evaluate the radio density of the implant. They were used non parametric tests to analyze the results. Results: The 7th PO boss remained in the two groups, but for 28th PO, observed reduction in the volume of the implant in Group A, not observed in group B. CT studies noticed different radio densities around all of S prostheses (pseudo capsule), that do not appeared in CPV implants. The S has remained unchanged in the CT, but the CPV has had a modification in its radio density (p{<=}0,05), in all implants. Conclusion: In CT evaluation the implants of CPV have greater deformation that the S, which makes them not suitable for replacement of membranous bone in the rat skull. (author)

  17. Phenolics composition and antidiabetic property of Brachystegia eurycoma seed flur in high-fat diet, low-dose streptozotocin-induced type 2 diabetes in rats

    Directory of Open Access Journals (Sweden)

    Emmanuel Anyachukwu Irondi

    2015-06-01

    Full Text Available Objective: To quantify some major pharmacologically important flavonoids and phenolic acids in Brachystegia eurycoma seed flour (BESF and evaluate its antidiabetic activity in type 2 diabetic rats. Method: Flavonoids and phenolic acids were quantified using a reverse-phase high pressure liquid chromatrography coupled with diode array detection. Type 2 diabetes was induced in rats using high-fat diet, low-dose streptozotocin (HFD/STZ model, by feeding the rats with HFD for 2 weeks followed by single dose administration of STZ (40 mg/kg body weight, intraperitoneally. The diabetic rats were later fed BESF-supplemented (10% and 20% diets, or administered with metformin (25 mg/kg b.w. for 21 days; the control rats were fed basal diet during this period. After the dietary regimen, the rats were sacrificed, and their blood, liver and pancreas samples were collected for biochemical assays. Results: The flavonoids (catechin, rutin, quercitrin, quercetin and kaempferol and phenolic acids (gallic acid, caffeic, chlorogenic and ellagic acid were abundant in BESF. BESFsupplemented diets (BESF-SD significantly (P 0.05 with metformin administration in some of the biomarkers. Conclusion: The flavonoids and phenolic acids in BESF may have acted synergistically to produce the observed antidiabetic effects. BESF could therefore be an effective and affordable dietary therapy for the management of T2DM; and an excellent source for drug discovery.

  18. "Ecstasy" toxicity to adolescent rats following an acute low binge dose.

    Science.gov (United States)

    Teixeira-Gomes, Armanda; Costa, Vera Marisa; Feio-Azevedo, Rita; Duarte, José Alberto; Duarte-Araújo, Margarida; Fernandes, Eduarda; Bastos, Maria de Lourdes; Carvalho, Félix; Capela, João Paulo

    2016-06-28

    3,4-Methylenedioxymethamphetamine (MDMA or "ecstasy") is a worldwide drug of abuse commonly used by adolescents. Most reports focus on MDMA's neurotoxicity and use high doses in adult animals, meanwhile studies in adolescents are scarce. We aimed to assess in rats the acute MDMA toxicity to the brain and peripheral organs using a binge dose scheme that tries to simulate human adolescent abuse. Adolescent rats (postnatal day 40) received three 5 mg/kg doses of MDMA (estimated equivalent to two/three pills in a 50 kg adolescent), intraperitoneally, every 2 h, while controls received saline. After 24 h animal sacrifice took place and collection of brain areas (cerebellum, hippocampus, frontal cortex and striatum) and peripheral organs (liver, heart and kidneys) occurred. Significant hyperthermia was observed after the second and third MDMA doses, with mean increases of 1 °C as it occurs in the human scenario. MDMA promoted ATP levels fall in the frontal cortex. No brain oxidative stress-related changes were observed after MDMA. MDMA-treated rat organs revealed significant histological tissue alterations including vascular congestion, but no signs of apoptosis or necrosis were found, which was corroborated by the lack of changes in plasma biomarkers and tissue caspases. In peripheral organs, MDMA did not affect significantly protein carbonylation, glutathione, or ATP levels, but liver presented a higher vulnerability as MDMA promoted an increase in quinoprotein levels. Adolescent rats exposed to a moderate MDMA dose, presented hyperthermia and acute tissue damage to peripheral organs without signs of brain oxidative stress.

  19. Escalating dose, multiple binge methamphetamine regimen does not impair recognition memory in rats.

    Science.gov (United States)

    Clark, Robert E; Kuczenski, Ronald; Segal, David S

    2007-07-01

    Rats exposed to methamphetamine (METH) in an acute high dose "binge" pattern have been reported to exhibit a persistent deficit in a novel object recognition (NOR) task, which may suggest a potential risk for human METH abusers. However, most high dose METH abusers initially use lower doses before progressively increasing the dose, only eventually engaging in multiple daily administrations. To simulate this pattern of METH exposure, we administered progressively increasing doses of METH to rats over a 14 day interval, then treated them with daily METH binges for 11 days. This treatment resulted in a persistent deficit in striatal dopamine (DA) levels of approximately 20%. We then tested them in a NOR task under a variety of conditions. We could not detect a deficit in their performance in the NOR task under any of the testing conditions. These results suggest that mechanisms other than or additional to the decrement in striatal DA associated with an acute METH binge are responsible for the deficit in the NOR task, and that neuroadaptations consequential to prolonged escalating dose METH pretreatment mitigate against these mechanisms.

  20. Efeitos das isoflavonas em altas doses sobre o útero da rata Effects of high-dose isoflavones on rat uterus

    Directory of Open Access Journals (Sweden)

    Adriana Aparecida Ferraz Carbonel

    2011-10-01

    Full Text Available OBJETIVO: Avaliar o efeito de altas doses de isoflavonas no útero de ratas adultas castradas. MÉTODOS: Ratas virgens ovariectomizadas (n = 40 foram tratadas por 30 dias consecutivos com veículo (GCtrl ou genisteína nas concentrações 42 (GES42, 125 (GES125 e 250 (GES250 µg/g de peso corporal ao dia. O extrato de soja e o veículo (propilenoglicol foram administrados por gavagem. Ao final do experimento, foi realizada dosagem sérica de 17 β-estradiol e progesterona, avaliou-se o peso dos animais e dos úteros e foi feito exame colpocitológico. Fragmentos do terço médio dos cornos uterinos foram fixados em formol a 10% e processados para inclusão em parafina para estudo histológico. Cortes de 5 µm de espessura foram corados pelo HE e destinados a estudo em microscopia de luz. Analisou-se a histomorfologia do endométrio, área endometrial, número e área ocupada pelas glândulas, assim como a concentração de eosinófilos presentes na lâmina própria. Os dados numéricos obtidos foram submetidos à análise de variância complementada pelo teste de Tukey-Kramer (p GES125 do que nos outros grupos (GES250 > GES125 > GES42 = GCtrl; p OBJECTIVE: To evaluate the effects of high-dose isoflavones on the uterus of castrated adult rats. METHODS: Adult, ovariectomized virgin rats (n = 40 were treated by gavage during 30 consecutive days with vehicle (propylene glycol, group GCtrl or different doses of genistein: 42 (group GES42, 125 (GES125, or 250 (GES250 µg/g body weight per day. Animals were killed, weighed, vaginal and uterine samples were taken for cytologic evaluation, and serum levels of 17 β-estradiol and progesterone were determined. The middle third of the uterine horns was dissected, fixed in 10% formaldehyde and processed for paraffin inclusion; 5-µm thick sections were obtained and stained with HE for further histological study under light microscopy. The endometrial morphology and area, number and area of glands, and number

  1. Long range implantation by MEVVA metal ion source

    International Nuclear Information System (INIS)

    Zhang Tonghe; Wu Yuguang; Ma Furong; Liang Hong

    2001-01-01

    Metal vapor vacuum arc (MEVVA) source ion implantation is a new technology used for achieving long range ion implantation. It is very important for research and application of the ion beam modification of materials. The results show that the implanted atom diffusion coefficient increases in Mo implanted Al with high ion flux and high dose. The implanted depth is 311.6 times greater than that of the corresponding ion range. The ion species, doses and ion fluxes play an important part in the long-range implantation. Especially, thermal atom chemistry have specific effect on the long-range implantation during high ion flux implantation at transient high target temperature

  2. Fetal hypothalamic transplants into brain irradiated rats: Graft morphometry and host behavioral responses

    International Nuclear Information System (INIS)

    Pearlman, S.H.; Rubin, P.; White, H.C.; Wiegand, S.J.; Gash, D.M.

    1990-01-01

    This study was designed to test the hypothesis that neural implants can ameliorate or prevent some of the long-term changes associated with CNS irradiation. Using a rat model, the initial study focused on establishing motor, regulatory, and morphological changes associated with brain radiation treatments. Secondly, fetal hypothalamic tissue grafts were placed into the third ventricle of rats which had been previously irradiated. Adult male Long Evans rats received one of three radiation doses (15, 22.5, ampersand 30 Gy) or no radiation. Three days after irradiation, 7 animals in each dose group received an embryonic day 17 hypothalamic graft into the third ventricle while the remaining 8-9 animals in each group received injections of vehicle solution (sham). Few changes were observed in the 15 and 22.5 Gy animals, however rats in the 30 Gy treatment group showed stereotypic and ambulatory behavioral hyperactivity 32 weeks after irradiation. Regulatory changes in the high dose group included decreased growth rate and decreased urine osmolalities, but these measures were extremely variable among animals. Morphological results demonstrated that 30 Gy irradiated animals showed extensive necrosis primarily in the fimbria, which extended into the internal capsule, optic nerve, hippocampus, and thalamus. Hemorrhages were found in the hippocampus, thalamus, and fimbria. Defects in the blood-brain barrier also were evident by entry of intravascularly injected horseradish peroxidase into the parenchyma of the brain. Animals in the 30 Gy grafted group showed fewer behavioral changes and less brain damage than their sham grafted counterparts. Specifically, activity measures were comparable to normal levels, and a dilute urine was not found in the 30 Gy implanted rats. Morphological changes support these behavioral results since only two 30 Gy implanted rats showed necrosis

  3. Chronic high-dose creatine has opposing effects on depression-related gene expression and behavior in intact and sex hormone-treated gonadectomized male and female rats.

    Science.gov (United States)

    Allen, Patricia J; DeBold, Joseph F; Rios, Maribel; Kanarek, Robin B

    2015-03-01

    Creatine is an antioxidant, neuromodulator and key regulator of energy metabolism shown to improve depressive symptoms in humans and animals, especially in females. To better understand the pharmacological effects of creatine, we examined its influence on depression-related hippocampal gene expression and behaviors in the presence and absence of sex steroids. Sham-operated and gonadectomized male and female rats were fed chow alone or chow blended with either 2% or 4% w/w creatine monohydrate for five weeks before forced swim, open field, and wire suspension tests, or seven weeks total. Before supplementation, males were chronically implanted with an empty or a testosterone-filled (T) capsule (10-mm surface release), and females were administered progesterone (P, 250 μg), estradiol benzoate (EB, 2.5 μg), EB+P, or sesame oil vehicle weekly. Relative to non-supplemented shams, all hippocampal plasticity-related mRNAs measured, including brain-derived neurotrophic factor (BDNF), tyrosine kinase B, doublecortin, calretinin, and calbindin, were downregulated in sham males given 4% creatine, and BDNF, doublecortin, and calbindin mRNAs were downregulated in sham females given 4% creatine. In contrast, combined 4% creatine+T in castrates prevented downregulation of BDNF, doublecortin, and calretinin mRNAs. Similarly, combined 4% creatine+EB+P in ovariectomized females attenuated downregulation of BDNF and calbindin mRNA levels. Moderate antidepressant and anxiolytic-like behaviors were observed in EB+P-treated ovariectomized females fed creatine, with similar trends in T-treated castrates fed creatine. Altogether, these data show that chronic, high-dose creatine has opposing effects on neuroplasticity-related genes and depressive behavior in intact and gonadectomized male and female rats. The dose and schedule of creatine used negatively impacted hippocampal neuronal integrity in otherwise healthy brains, possibly through negative compensatory changes in energy

  4. Formation of low friction and wear-resistant carbon coatings on tool steel by 75keV, high-dose carbon ion implantation

    International Nuclear Information System (INIS)

    Mikkelsen, N.J.; Eskildsen, S.S.; Straede, C.A.; Chechenin, N.G.

    1994-01-01

    Hardened AISI D2 steel samples were subjected to mass-separated C + ion bombardment at 75keV with ion doses in the range 0.5-15x10 18 C + cm -2 . It was observed that sputtering was still limited, and the system exhibited internal growth, because most of the ions penetrated more than 0.1μm into the growing carbon film. At the lowest ion doses applied, carbon was implanted into the steel, while higher doses resulted in the implanted carbon concentration near the surface being almost 100%. For the highest doses applied, Rutherford backscattering spectrometry and surface profilometry analyses showed that layers about 0.5-1μm thick of almost pure carbon grew outward from the steel substrate. Transmission electron microscopy showed that the carbon layers were amorphous and exhibited an intermixed layer-substrate interface. The layers were hard and exhibited pronounced elastic recovery when subjected to ultralow load indentation. Low friction and excellent wear properties were measured when tested under dry conditions with a ball-on-disc tribometer. ((orig.))

  5. Preservation and release dose of helium implanted in nanocrystal titanium film

    International Nuclear Information System (INIS)

    Long Xinggui; Luo Shunzhong; Peng Shuming; Zheng Sixiao; Liu Zhongyang; Wang Peilu; Liao Xiaodong; Liu Ning

    2003-01-01

    Helium concentration profile, preservation dose and release rate from a nanocrystal titanium film implanted with helium at an energy of 100 keV and dose of 2.2 x 10 18 cm -2 are measured by proton Rutherford backscattering technique in a range from room temperature to 400 degree C. The implanted helium may be stably preserved up to the 68 percent after keeping a long time of 210 d in the nanocrystal titanium film at the room temperature environment, and the He-Ti atomic ratio reaches to 52.6%. When the temperature of specimen increases to 100 degree C, the helium concentration can be preserved to 89.6% of the keeping helium dose at room temperature and He-Ti atomic ratio reaches 44%. Even if the specimen temperature up to 400 degree C, the helium concentration still can be preserved to 32.6% of the keeping helium dose at room temperature and the He-Ti atomic ratio is 17.1%. Possible mechanism of helium effectively preserved in the nanocrystal titanium film is discussed based on the energy stability viewpoint

  6. Safety assessments of subcutaneous doses of aragonite calcium carbonate nanocrystals in rats

    Science.gov (United States)

    Jaji, Alhaji Zubair; Zakaria, Zuki Abu Bakar; Mahmud, Rozi; Loqman, Mohamad Yusof; Hezmee, Mohamad Noor Mohamad; Abba, Yusuf; Isa, Tijani; Mahmood, Saffanah Khuder

    2017-05-01

    Calcium carbonate nanoparticles have shown promising potentials in the delivery of drugs and metabolites. There is however, a paucity of information on the safety of their intentional or accidental over exposures to biological systems and general health safety. To this end, this study aims at documenting information on the safety of subcutaneous doses of biogenic nanocrystals of aragonite polymorph of calcium carbonate derived from cockle shells (ANC) in Sprague-Dawley (SD) rats. ANC was synthesized using the top-down method, characterized using the transmission electron microscopy and field emission scanning electron microscope and its acute and repeated dose 28-day trial toxicities were evaluated in SD rats. The results showed that the homogenous 30 ± 5 nm-sized spherical pure aragonite nanocrystals were not associated with mortality in the rats. Severe clinical signs and gross and histopathological lesions, indicating organ toxicities, were recorded in the acute toxicity (29,500 mg/m2) group and the high dose (5900 mg/m2) group of the repeated dose 28-day trial. However, the medium- (590 mg/m2 body weight) and low (59 mg/m2)-dose groups showed moderate to mild lesions. The relatively mild lesions observed in the low toxicity dosage group marked the safety margin of ANC in SD rats. It was concluded from this study that the toxicity of CaCO3 was dependent on the particulate size (30 ± 5 nm) and concentration and the route of administration used.

  7. Implant Gigi One-Piece Vs Two-Pieces Dalam Praktek Sehari-Hari

    OpenAIRE

    Kurnia, Dian Lestari; Ramadhani, Amilia; Hudyono, Rikko

    2014-01-01

    Saat ini, implant merupakan pilihan terbaik untuk menggantikan gigi yang tanggal, akan tetapi prosedur pemasangannya terbilang rumit dan memerlukan prosedur bedah kedua untuk pemasangan prostetik. Beberapa komplikasi seperti screw patah atau longgar dan adanya celah mikro pada batas pertemuan implant dan abutment dapat menyebabkan kegagalan implant. Studi kasus ini bertujuan untuk membahas mengenai keuntungan dan kerugian desain implant gigi one-piece dan two-pieces. Kasus pertama, seorang wa...

  8. Implantation of Octacalcium Phosphate Stimulates both Chondrogenesis and Osteogenesis in the Tibia, but Only Osteogenesis in the Rat Mandible

    Directory of Open Access Journals (Sweden)

    F. Sargolzaei Aval

    2006-09-01

    Full Text Available Statement of problem: It is not known whether endochondral and intramembranous bones have distinct biological characteristics. Octacalcium Phosphate (OCP, a hydroxyapatite precursor, has been reported to stimulate bone formation after being implanted in parietal bone defects of rats.Purpose: The present study was designed to investigate the response of endochondral and intramembranous bones to OCP implantation and to compare their biological characteristicsMaterials and Methods: Full-thickness standardized trephine defects were made in rat tibiae and mandibles and synthetic OCP was implanted into the defects. The biologic response was examined histologically to identify bone and cartilage formation.Results: Both chondrogenesis and osteogenesis were initiated in the tibia, 1 week after implantation of OCP and most of the cartilage was replaced by bone at week 2.However, the mandible only showed osteogenesis in response to OCP implantation at week 2, and no cartilage formation was associated with the osteogenesis.Conclusions: According to the results obtained in the present study, endochondral and intramembranous bones exhibit different biological responses to OCP implantation in rats.

  9. Cannabis sativa smoke inhalation decreases bone filling around titanium implants: a histomorphometric study in rats.

    Science.gov (United States)

    Nogueira-Filho, Getulio da R; Cadide, Tiago; Rosa, Bruno T; Neiva, Tiago G; Tunes, Roberto; Peruzzo, Daiane; Nociti, Francisco Humberto; César-Neto, João B

    2008-12-01

    Although the harmful effect of tobacco smoking on titanium implants has been documented, no studies have investigated the effects of cannabis sativa (marijuana) smoking. Thus, this study investigated whether marijuana smoke influences bone healing around titanium implants. Thirty Wistar rats were used. After anesthesia, the tibiae surface was exposed and 1 screw-shaped titanium implant was placed bilaterally. The animals were randomly assigned to one of the following groups: control (n = 15) and marijuana smoke inhalation (MSI) 8 min/d (n = 15). Urine samples were obtained to detect the presence of tetra-hidro-cannabinoid. After 60 days, the animals were killed. The degree of bone-to-implant contact and the bone area within the limits of the threads of the implant were measured in the cortical (zone A) and cancellous bone (zone B). Tetra-hidro-cannabinoid in urine was positive only for the rats of MSI group. Intergroup analysis did not indicate differences in zone A-cortical bone (P > 0.01), however, a negative effect of marijuana smoke (MSI group) was observed in zone B-cancellous bone for bone-to-implant contact and bone area (Student's t test, P smoke on bone healing may represent a new concern for implant success/failure.

  10. Light, electron microscopic and immunohistochemical study of the effect of low-dose aspirin during the proestrus phase on rat endometrium in the preimplantation period.

    Science.gov (United States)

    Ateş, Utku; Baka, Meral; Turgut, Mehmet; Uyanikgil, Yiğit; Ulker, Sibel; Yilmaz, Ozlem; Tavmergen, Erol; Yurtseven, Mine

    2007-04-01

    To evaluate structural alterations in rat endometrium at preimplantation following treatment with aspirin beginning from proestrus by light microscopy, electron microscopy and immunohistochemical techniques. Twenty rats were divided into control (n = 10) and experimental (n = 10) groups. Experimental rats were treated with low-dose aspirin daily (2 mg/kg/day) during estrus, beginning from the proestrus phase, mated at end of cycle and treated with aspirin. Untreated pregnant rats were the control group. Rats in both groups were sacrificed at the 84th pregnancy hour; the uterus was rapidly removed and dissected free of surrounding adipose tissue. Uteri specimens from nonpregnant rats were transferred into fixative solution and processed for light, electron microscopic and immunohistochemical study. Light and electron microscopy of endometrium from control rats conformed to mid-diestrus phase; endometrial histology of the aspirin-treated group conformed to late diestrus phase. The endometrial layer was significantly thicker in the aspirin-treated group compared to the untreated control group (p <0.001). No significant difference was found in vessel number between groups. Staining with alphaV integrin was more dense in the aspirin-treated group. Based on histologic findings, we suggest low-dose aspirin has positive effects on preparing endometrium before implantation.

  11. Influences of serum from ozone-exposed pregnant rats in an in vitro model of implantation

    Science.gov (United States)

    In our previous studies, ozone (O3) exposure during implantation [gestational day (GD) 5 and 6)] in rats resulted in intrauterine growth restriction (IUGR), suggesting impairment of implantation with exposure. The aim of this study was to (1) determine if serum collected from pre...

  12. Structural investigations of amorphised iron and nickel by high-fluence metalloid ion implantation

    International Nuclear Information System (INIS)

    Rauschenbach, B.; Otto, G.; Hohmuth, K.; Heera, V.

    1987-01-01

    Boron, phosphorus and arsenic ions have been implanted into evaporated iron and nickel thin films at room temperature, and the implantation-induced microstructure has been investigated by high-voltage electron microscopy and transmission high energy electron diffraction. The metal films were implanted with ions to a constant dose of 1 x 10 17 and 5 x 10 17 ions/cm 2 respectively at energy of 50 keV. An amorphous layer was produced by boron and phosphorus ion implantation. Information on the atomic structure of the amorphous layers was obtained from the elastically diffracted electron intensity. On the basis of the correct scattering curves, the total interference function and the pair correlation function were determined. Finally, the atomic arrangement of the implantation-induced amorphous layers is discussed and structure produced by ion irradiation is compared with amorphous structures formed with other techniques. (author)

  13. High doses of L-naloxone but neither D-naloxone nor beta-funaltrexamine prevent hyperthermia-induced seizures in rat pups.

    Science.gov (United States)

    Laorden, M L; Miralles, F S; Puig, M M

    1988-03-01

    The effects of the non-specific opiate antagonist L-naloxone and the inactive isomer D-naloxone, as well as the specific mu receptor antagonist beta-funaltrexamine, have been examined on hyperthermia-induced seizures in unrestrained 15 days old rats. Saline-injected animals exposed to an ambient temperature of 40 degrees C showed a gradual increase in body temperature reaching a maximum of 42 +/- 0.1 degrees C at 50 min exposure. At this time all the pups had seizures and died. Similar results were obtained when the animals were pretreated with different doses of D-naloxone and beta-funaltrexamine. Rats pretreated with L-naloxone also showed an increase in rectal temperature; but the temperature was lower than in saline-injected animals. Only high doses of L-naloxone prevented seizures and deaths. These data indicate that endogenous opioid peptides may play a role in seizures induced by hyperthermia and that receptors other than mu receptors could be involved in hyperthermia-induced seizures.

  14. Positron and nanoindentation study of helium implanted high chromium ODS steels

    Science.gov (United States)

    Veternikova, Jana Simeg; Fides, Martin; Degmova, Jarmila; Sojak, Stanislav; Petriska, Martin; Slugen, Vladimir

    2017-12-01

    Three oxide dispersion strengthened (ODS) steels with different chromium content (MA 956, MA 957 and ODM 751) were studied as candidate materials for new nuclear reactors in term of their radiation stability. The radiation damage was experimentally simulated by helium ion implantation with energy of ions up to 500 keV. The study was focused on surface and sub-surface structural change due to the ion implantation observed by mostly non-destructive techniques: positron annihilation lifetime spectroscopy and nanoindentation. The applied techniques demonstrated the best radiation stability of the steel ODM 751. Blistering effect occurred due to high implantation dose (mostly in MA 956) was studied in details.

  15. The Effect of Different Doses of Vitamin D Supplementation on Insulin Resistance in ovariectomized rats

    Directory of Open Access Journals (Sweden)

    Rastegar Hoseini

    2016-04-01

    Full Text Available Background and Aim: Type 2 diabetes mellitus (T2DM and vitamin D deficiency are both too common during menopause. Since the effect of different doses of vitamin D supplements on blood sugar, insulin concentration  and insulin resistance are unknown, the present study aimed at investigating the effects of different doses of the vitamin D supplements on visceral fat, blood sugar, insulin concentration,  and insulin resistance in ovariectomized rats. Materials and Methods: In this randomized experimental study, 32 female Wistar rats were divided into 4 equal groups  as follows: three groups . that received vitamin D supplements (high, moderate, and low dose and one control group. After 8 weeks of different doses of vitamin D supplementation plasma concentration of glucose, insulin and HOMA-IR were measured  in the three groups. The obtained data  was statistically analyzed by means of dependent t-test and ANOVA . at the significance level of P<0.05. Results: After a period of eight-week  intervention, body weight, BMI, waist circumference, visceral fat, insulin, blood glucose and HOMA-IR at high, moderate, and low doses of vitamin D supplementation were significantly lower than those in the control group (P<0.05. High dose of vitamin D compared with moderate and low doses significantly caused reduction in insulin, blood glucose, and HOMA-IR (P<0.001 for all three variables. Conclusion: The findings of the current study showed that a high dose of vitamin D causes significant improvements in FPG, insulin, and insulin resistance  evaluated by HOMA-IR. It was also found that adding vitamin D supplements can improve glucose control in menopause model of rats.

  16. Implant Gigi One-Piece vs Two-Pieces dalam Praktek Sehari-Hari

    OpenAIRE

    Kurnia, Dian Lestari; Ramadhani, Amilia; Hudyono, Rikko

    2014-01-01

    Saat ini, implant merupakan pilihan terbaik untuk menggantikan gigi yang tanggal, akan tetapi prosedur pemasangannya terbilang rumit dan memerlukan prosedur bedah kedua untuk pemasangan prostetik. Beberapa komplikasi seperti screw patah atau longgar dan adanya celah mikro pada batas pertemuan implant dan abutment dapat menyebabkan kegagalan implant. Studi kasus ini bertujuan untuk membahas mengenai keuntungan dan kerugian desain implant gigi one-piece dan two-pieces. Kasus pertama, seorang wa...

  17. A 13-week repeated dose study of three 3-monochloropropane-1,2-diol fatty acid esters in F344 rats.

    Science.gov (United States)

    Onami, Saeko; Cho, Young-Man; Toyoda, Takeshi; Mizuta, Yasuko; Yoshida, Midori; Nishikawa, Akiyoshi; Ogawa, Kumiko

    2014-04-01

    3-monochloropropane-1,2-diol (3-MCPD), a rat renal and testicular carcinogen, has been reported to occur in various foods and food ingredients as free or esterified forms. Since reports about toxicity of 3-MCPD esters are limited, we conducted a 13-week rat subchronic toxicity study of 3-MCPD esters (palmitate diester: CDP, palmitate monoester: CMP, oleate diester: CDO). We administered a carcinogenic dose (3.6 × 10(-4) mol/kg B.W./day) of 3-MCPD or these esters at equimolar concentrations and two 1/4 lower doses by gavage with olive oil as a vehicle five times a week for 13 weeks to F344 male and female rats. As a result, five out of ten 3-MCPD-treated females died from acute renal tubular necrosis, but none of the ester-treated rats. Decreased HGB was observed in all high-dose 3-MCPD fatty acid ester-treated rats, except CDO-treated males. The absolute and relative kidney weights were significantly increased in the ester-treated rats at medium and high doses. Relative liver weights were significantly increased in the esters-treated rat at high dose, except for CMP females. Significant increase in apoptotic epithelial cells in the initial segment of the epididymis of high-dose ester-treated males was also observed. The results suggested that although acute renal toxicity was lower than 3-MCPD, these three 3-MCPD fatty acid esters have the potential to exert subchronic toxicity to the rat kidneys and epididymis, to a similar degree as 3-MCPD under the present conditions. NOAELs (no-observed-adverse-effect levels) of CDP, CMP and CDO were suggested to be 14, 8 and 15 mg/kg B.W./day, respectively.

  18. Halofuginone Inhibits Angiogenesis and Growth in Implanted Metastatic Rat Brain Tumor Model-an MRI Study

    Directory of Open Access Journals (Sweden)

    Rinat Abramovitch

    2004-09-01

    Full Text Available Tumor growth and metastasis depend on angiogenesis; therefore, efforts are made to develop specific angiogenic inhibitors. Halofuginone (HF is a potent inhibitor of collagen type α1(I. In solid tumor models, HF has a potent antitumor and antiangiogenic effect in vivo, but its effect on brain tumors has not yet been evaluated. By employing magnetic resonance imaging (MRI, we monitored the effect of HF on tumor progression and vascularization by utilizing an implanted malignant fibrous histiocytoma metastatic rat brain tumor model. Here we demonstrate that treatment with HF effectively and dose-dependently reduced tumor growth and angiogenesis. On day 13, HF-treated tumors were fivefold smaller than control (P < .001. Treatment with HF significantly prolonged survival of treated animals (142%; P = .001. In HF-treated rats, tumor vascularization was inhibited by 30% on day 13 and by 37% on day 19 (P < .05. Additionally, HF treatment inhibited vessel maturation (P = .03. Finally, in HF-treated rats, we noticed the appearance of a few clusters of satellite tumors, which were distinct from the primary tumor and usually contained vessel cores. This phenomenon was relatively moderate when compared to previous reports of other antiangiogenic agents used to treat brain tumors. We therefore conclude that HF is effective for treatment of metastatic brain tumors.

  19. Dynamics of pathomorphological changes in rat brain as a function of γ-radiation dose

    International Nuclear Information System (INIS)

    Fedorov, V.P.

    1990-01-01

    Neurohistological, histochemical, electron-microscopic and biometric techniques were used to study the response of rat brain to irradiation within a wide range of doses. Nerve cells were shown to be highly radioresistant. At the same time, synapses and blood-brain barrier structures were highly radiosensitive. The pathomorphologic changes in different brain areas followed a dose-time function

  20. Effect of feeding graded doses of Citrinin on clinical and teratology in female Wistar rats.

    Science.gov (United States)

    Singh, N D; Sharma, A K; Patil, R D; Rahman, S; Leishangthem, G D; Kumar, M

    2014-02-01

    Citrinin is the one of the well-known mycotoxins, which is possibly spread all over the world. The graded doses of citrinin (1, 3 and 5 ppm CIT in feed) in female Wistar rats 10 weeks prior to mating, during mating and during organogenesis resulted in resorptions and post implantation losses, decreased fetal body weights and crown-rump lengths in fetuses of all groups. Various developmental anomalies recorded in fetuses of treated rats included gross (wrist drop, curled tail, stretched forelimb, subcutaneous haematoma), skeletal (incomplete ossification of skull bones, incomplete fusion of vertebral bodies, complete and partial agenesis of sternaebrae, metacarpals, metatarsals and phalanges, fused ribs and swing out ribs) and visceral (internal and external hydrocephalus, cerebellar hypoplasia, microphthalmia, roundening of heart, contracted kidneys, dilated renal pelvis and cryptorchid testes). The results suggest that CIT has adverse effects on fetal development which may be due to the longer bioavailability of citrinin in the animals.

  1. Hormones of thyroid gland in sera of rats treated with different dose of concentrated potassium iodine solutions

    Directory of Open Access Journals (Sweden)

    Marković Ljiljana

    2010-01-01

    Full Text Available Introduction Potassium iodine (KI is used as a drug therapy for treating numerous diseases such as small-vessel vasculitis, erythema nodosum, vasculitis nodularis, Sweet's syndrome, tuberculosis and granulomatosis, and for iodized salt. At the same time, KI can be harmful. Iodine intake may increase the frequency of thyroiditis in humans, and may induce the occurrence of experimental thyroiditis (ET in animals. Investigations on an experimental model for the examination of thyroiditis in Wistar rats have clearly showed morphological changes in the rat thyroid evoked by KI administration. Objective The purpose of this study was to compare the effects of low and high doses of KI on the thyroid gland of Wistar rats and determine the effect on hormone status (T4, T3 and TSH in this rat strain. Methods Two groups of rats from the Wistar strain were treated with a low iodine dose (225 μg/g BW and with a high iodine dose (675 μg/g BW of KI solutions. Untreated nonimmunized animals served as controls. The solution was administrated daily intraperitoneally during the period of 26 consecutive days. Results Monitoring hormone status (TSH, T3 and T4 and morphological changes it was found that therapeutic doses of KI applied in treatment induced the occurrence of experimental thyroiditis (chronic destructive Hashimoto's thyroiditis in humans and cell necrosis in animals not carrying a genetic susceptibility. Significant inflammatory changes were observed in rats treated with a high iodine dose. Conclusion The early iodine induced cell necrosis and inflammation in the nonimmunized animals without genetic susceptibility is a new experimental model of thyroiditis. .

  2. Metabolic kinetics and absorbed doses of 137Cs in lactating rats and progeny during suckling

    International Nuclear Information System (INIS)

    Lyaginskaya, A.M.; Osipov, V.A.; Dement'ev, S.I.; Ermalitskij, A.P.

    2000-01-01

    The transfer of 137 Cs with maternal milk to progeny was studied in rats The rats were administered with 25 kBq/g of 137 Cs nitrate (pH = 6) in a single oral dose immediately after delivery. Nonpregnant females served as control. Absorbed doses per activity unit to lactating rats were 23 % lover than to nonlactating ones. Over the suckling period absorbed doses to young rats amounted to about 35 % of the absorbed dose to the nursing female. For nonlactating females the internal dose approximately equalled the sum of doses to the nursing female and young rats. Lactating is the effective way for removal of 1 '3 7 Cs from organism of the rats. Content of 1 '3 7 Cs in lactating rat becomes on 42.9 % lower than in organism of nonlactating rat during period of lactating (near 20 days) [ru

  3. The Fe Ion Implantation of High Dose on the Ag Substrate for GMRApplications

    International Nuclear Information System (INIS)

    Sudjatmoko; Tri-Mardji-Atmono; Tjipto-Sujitno

    2000-01-01

    In this research the implantation of Fe ions on the Ag substrate withsome variation of ion dose and energy as well as annealing temperature havebeen done. The aim of this research was to obtain the magnetic thin filmswhich has a minimum specific resistance and a optimum GMR ratio. On the ionimplantation process the variation of ion dose from 1.5 x 10 17 ions/cm 2 upto 9.0 x 10 17 ions/cm 2 and ion energy from 40 keV to 100 keV. After ionimplantation the samples was annealed on the temperatures of 100 o C, 300 o Cand 500 o C during 30 minutes, respectively. The specific resistance ofsamples were measured by using a four point probe, and the magnetoresistancewas obtained by measuring the specific resistance of samples in the magneticfield. The microstructure of samples was investigated by using SEM and thechanging of the chemical composition was determined by EDAXS. Based on thedata analysis was obtained that the minimum specific resistance was (167 ±3) x 10 -9 Ωm and the optimum GMR ratio was 64.9 % were occurred oncondition of the ion dose of 6.0 x 10 17 ions/cm 2 , the ion energy of 100keV and the annealing temperature of 300 o C. The analysis of chemicalcomposition on the optimum condition was obtained that the content of Feelement was 1.13 % weight. (author)

  4. SU-E-I-34: Intermittent Low- and High-Dose Ethanol Exposure Alters Neurochemical Responses in Adult Rat Brain: An Ex Vivo 1H NMR Spectroscopy at 11.7 T

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do-Wan; Kim, Sang-Young; Song, Kyu-Ho; Choe, Bo-Young [Department of Biomedical Engineering, and Research Institute of Biomedical Engineering, The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The first goal of this study was to determine the influence of the dose-dependent effects of intermittent ethanol intoxication on cerebral neurochemical responses among sham controls and low- and high-dose-ethanol-exposed rats with ex vivo high-resolution spectra. The second goal of this study was to determine the correlations between the metabolite-metabolite levels (pairs-of-metabolite levels) from all of the individual data from the frontal cortex of the intermittent ethanol-intoxicated rats. Methods: Eight-week-old male Wistar rats were divided into 3 groups. Twenty rats in the LDE (n = 10) and the HDE (n = 10) groups received ethanol doses of 1.5 g/kg and 2.5 g/kg, respectively, through oral gavage every 8-h for 4 days. At the end of the 4-day intermittent ethanol exposure, one-dimensional ex vivo 500-MHz proton nuclear magnetic resonance spectra were acquired from 30 samples of the frontal cortex region (from the 3 groups). Results: Normalized total-N-acetylaspartate (tNAA: NAA + NAAG [N-acetylaspartyl-glutamate]), gamma-aminobutyric acid (GABA), and glutathione (GSH) levels were significantly lower in the frontal cortex of the HDE-exposed rats than that of the LDE-exposed rats. Moreover, compared to the CNTL group, the LDE rats exhibited significantly higher normalized GABA levels. The 6 pairs of normalized metabolite levels were positively (+) or negatively (−) correlated in the rat frontal cortex as follows: tNAA and GABA (+), tNAA and Aspartate (Asp) (−), myo-Inositol (mIns) and Asp (−), mIns and Alanine (+), mIns and Taurine (+), and mIns and tNAA (−). Conclusion: Our results suggested that repeated intermittent ethanol intoxication might result in neuronal degeneration and dysfunction, changes in the rate of GABA synthesis, and oxidative stress in the rat frontal cortex. Our ex vivo 1H high-resolution-magic angle spinning nuclear magnetic resonance spectroscopy results suggested some novel metabolic markers for the dose

  5. SU-E-I-34: Intermittent Low- and High-Dose Ethanol Exposure Alters Neurochemical Responses in Adult Rat Brain: An Ex Vivo 1H NMR Spectroscopy at 11.7 T

    International Nuclear Information System (INIS)

    Lee, Do-Wan; Kim, Sang-Young; Song, Kyu-Ho; Choe, Bo-Young

    2014-01-01

    Purpose: The first goal of this study was to determine the influence of the dose-dependent effects of intermittent ethanol intoxication on cerebral neurochemical responses among sham controls and low- and high-dose-ethanol-exposed rats with ex vivo high-resolution spectra. The second goal of this study was to determine the correlations between the metabolite-metabolite levels (pairs-of-metabolite levels) from all of the individual data from the frontal cortex of the intermittent ethanol-intoxicated rats. Methods: Eight-week-old male Wistar rats were divided into 3 groups. Twenty rats in the LDE (n = 10) and the HDE (n = 10) groups received ethanol doses of 1.5 g/kg and 2.5 g/kg, respectively, through oral gavage every 8-h for 4 days. At the end of the 4-day intermittent ethanol exposure, one-dimensional ex vivo 500-MHz proton nuclear magnetic resonance spectra were acquired from 30 samples of the frontal cortex region (from the 3 groups). Results: Normalized total-N-acetylaspartate (tNAA: NAA + NAAG [N-acetylaspartyl-glutamate]), gamma-aminobutyric acid (GABA), and glutathione (GSH) levels were significantly lower in the frontal cortex of the HDE-exposed rats than that of the LDE-exposed rats. Moreover, compared to the CNTL group, the LDE rats exhibited significantly higher normalized GABA levels. The 6 pairs of normalized metabolite levels were positively (+) or negatively (−) correlated in the rat frontal cortex as follows: tNAA and GABA (+), tNAA and Aspartate (Asp) (−), myo-Inositol (mIns) and Asp (−), mIns and Alanine (+), mIns and Taurine (+), and mIns and tNAA (−). Conclusion: Our results suggested that repeated intermittent ethanol intoxication might result in neuronal degeneration and dysfunction, changes in the rate of GABA synthesis, and oxidative stress in the rat frontal cortex. Our ex vivo 1H high-resolution-magic angle spinning nuclear magnetic resonance spectroscopy results suggested some novel metabolic markers for the dose

  6. A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality.

    Science.gov (United States)

    Hoerth, Rebecca M; Katunar, María R; Gomez Sanchez, Andrea; Orellano, Juan C; Ceré, Silvia M; Wagermaier, Wolfgang; Ballarre, Josefina

    2014-02-01

    Permanent metal implants are widely used in human medical treatments and orthopedics, for example as hip joint replacements. They are commonly made of titanium alloys and beyond the optimization of this established material, it is also essential to explore alternative implant materials in view of improved osseointegration. The aim of our study was to characterize the implant performance of zirconium in comparison to titanium implants. Zirconium implants have been characterized in a previous study concerning material properties and surface characteristics in vitro, such as oxide layer thickness and surface roughness. In the present study, we compare bone material quality around zirconium and titanium implants in terms of osseointegration and therefore characterized bone material properties in a rat model using a multi-method approach. We used light and electron microscopy, micro Raman spectroscopy, micro X-ray fluorescence and X-ray scattering techniques to investigate the osseointegration in terms of compositional and structural properties of the newly formed bone. Regarding the mineralization level, the mineral composition, and the alignment and order of the mineral particles, our results show that the maturity of the newly formed bone after 8 weeks of implantation is already very high. In conclusion, the bone material quality obtained for zirconium implants is at least as good as for titanium. It seems that the zirconium implants can be a good candidate for using as permanent metal prosthesis for orthopedic treatments.

  7. Dose perturbation in the presence of metallic implants: treatment planning system versus Monte Carlo simulations

    International Nuclear Information System (INIS)

    Wieslander, Elinore; Knoeoes, Tommy

    2003-01-01

    An increasing number of patients receiving radiation therapy have metallic implants such as hip prostheses. Therefore, beams are normally set up to avoid irradiation through the implant; however, this cannot always be accomplished. In such situations, knowledge of the accuracy of the used treatment planning system (TPS) is required. Two algorithms, the pencil beam (PB) and the collapsed cone (CC), are implemented in the studied TPS. Comparisons are made with Monte Carlo simulations for 6 and 18 MV. The studied materials are steel, CoCrMo, Orthinox(a stainless steel alloy and registered trademark of Stryker Corporation), TiAlV and Ti. Monte Carlo simulated depth dose curves and dose profiles are compared to CC and PB calculated data. The CC algorithm shows overall a better agreement with Monte Carlo than the PB algorithm. Thus, it is recommended to use the CC algorithm to get the most accurate dose calculation both for the planning target volume and for tissues adjacent to the implants when beams are set up to pass through implants

  8. Ge-semiconductor detectors with a p-implanted n+-contact

    International Nuclear Information System (INIS)

    Protic, D.; Riepe, G.

    1979-01-01

    P-implanted large-surface-detectors with improved properties can be produced by implantation of the n + -contact with relatively low dose and high energy. After an annealing process a nearly perfect lattice structure is obtained. By a subsequent p-implantation step with high dose and low energy, the surface restisivity can be reduced. The p + -contacts are obtained by B-implantation. (DG) [de

  9. 125I Monotherapy Using D90 Implant Doses of 180 Gy or Greater

    International Nuclear Information System (INIS)

    Kao, Johnny; Stone, Nelson N.; Lavaf, Amir; Dumane, Vishruta; Cesaretti, Jamie A.; Stock, Richard G.

    2008-01-01

    Purpose: The purpose of this study was to characterize the oncologic results and toxicity profile of patients treated with 125 I implants using the dose delivered to 90% of the gland from the dose-volume histogram (D90) of greater than 144 Gy. Methods and Materials: From June 1995 to Feb 2005, a total of 643 patients were treated with 125 I monotherapy for T1-T2 prostate cancer with a D90 of 180 Gy or greater (median, 197 Gy; range, 180-267 Gy). Implantations were performed using a real-time ultrasound-guided seed-placement method and intraoperative dosimetry to optimize target coverage and homogeneity by using modified peripheral loading. We analyzed biochemical disease-free survival (bDFS) of 435 patients who had a minimum 2-year prostate-specific antigen follow-up (median follow-up, 6.7 years; range, 2.0-11.1 years). Results: Five-year bDFS rates for the entire cohort using the American Society for Therapeutic Radiology and Oncology and Phoenix definitions were 96.9% and 96.5%, respectively. Using the Phoenix definition, 5-year bDFS rates were 97.3% for low-risk patients and 92.8% for intermediate/high-risk patients. The positive biopsy rate was 4.1%. The freedom rate from Grade 2 or higher rectal bleeding at 5 years was 88.5%. Acute urinary retention occurred in 10.7%, more commonly in patients with high pretreatment International Prostate Symptom Scores (p < 0.01). In patients who were potent before treatment, 73.4% remained potent at 5 years after implantation. Conclusions: Patients with a minimum D90 of 180 Gy had outstanding local control based on prostate-specific antigen control and biopsy data. Toxicity profiles, particularly for long-term urinary and sexual function, were excellent and showed that D90 doses of 180 Gy or greater performed using the technique described were feasible and tolerable

  10. Chronic implantation of cuff electrodes on the pelvic nerve in rats is well tolerated and does not compromise afferent or efferent fibre functionality

    Science.gov (United States)

    Crook, J. J.; Brouillard, C. B. J.; Irazoqui, P. P.; Lovick, T. A.

    2018-04-01

    Objective. Neuromodulation of autonomic nerve activity to regulate physiological processes is an emerging field. Vagal stimulation has received most attention whereas the potential of modulate visceral function by targeting autonomic nerves within the abdominal cavity remains under-exploited. Surgery to locate intra-abdominal targets is inherently more stressful than for peripheral nerves. Electrode leads risk becoming entrapped by intestines and loss of functionality in the nerve-target organ connection could result from electrode migration or twisting. Since nociceptor afferents are intermingled with similar-sized visceral autonomic fibres, stimulation may induce pain. In anaesthetised rats high frequency stimulation of the pelvic nerve can suppress urinary voiding but it is not known how conscious animals would react to this procedure. Our objective therefore was to determine how rats tolerated chronic implantation of cuff electrodes on the pelvic nerve, whether nerve stimulation would be aversive and whether nerve-bladder functionality would be compromised. Approach. We carried out a preliminary de-risking study to investigate how conscious rats tolerated chronic implantation of electrodes on the pelvic nerve, their responsiveness to intermittent high frequency stimulation and whether functionality of the nerve-bladder connection became compromised. Main results. Implantation of cuff electrodes was well-tolerated. The normal diurnal pattern of urinary voiding was not disrupted. Pelvic nerve stimulation (up to 4 mA, 3 kHz) for 30 min periods evoked mild alerting at stimulus onset but no signs of pain. Stimulation evoked a modest (nerve temperature but the functional integrity of the nerve-bladder connection, reflected by contraction of the detrusor muscle in response to 10 Hz nerve stimulation, was not compromised. Significance. Chronic implantation of cuff electrodes on the pelvic nerve was found to be a well-tolerated procedure in rats and high frequency

  11. BEDVH--A method for evaluating biologically effective dose volume histograms: Application to eye plaque brachytherapy implants

    International Nuclear Information System (INIS)

    Gagne, Nolan L.; Leonard, Kara L.; Huber, Kathryn E.; Mignano, John E.; Duker, Jay S.; Laver, Nora V.; Rivard, Mark J.

    2012-01-01

    Purpose: A method is introduced to examine the influence of implant duration T, radionuclide, and radiobiological parameters on the biologically effective dose (BED) throughout the entire volume of regions of interest for episcleral brachytherapy using available radionuclides. This method is employed to evaluate a particular eye plaque brachytherapy implant in a radiobiological context. Methods: A reference eye geometry and 16 mm COMS eye plaque loaded with 103 Pd, 125 I, or 131 Cs sources were examined with dose distributions accounting for plaque heterogeneities. For a standardized 7 day implant, doses to 90% of the tumor volume ( TUMOR D 90 ) and 10% of the organ at risk volumes ( OAR D 10 ) were calculated. The BED equation from Dale and Jones and published α/β and μ parameters were incorporated with dose volume histograms (DVHs) for various T values such as T = 7 days (i.e., TUMOR 7 BED 10 and OAR 7 BED 10 ). By calculating BED throughout the volumes, biologically effective dose volume histograms (BEDVHs) were developed for tumor and OARs. Influence of T, radionuclide choice, and radiobiological parameters on TUMOR BEDVH and OAR BEDVH were examined. The nominal dose was scaled for shorter implants to achieve biological equivalence. Results: TUMOR D 90 values were 102, 112, and 110 Gy for 103 Pd, 125 I, and 131 Cs, respectively. Corresponding TUMOR 7 BED 10 values were 124, 140, and 138 Gy, respectively. As T decreased from 7 to 0.01 days, the isobiologically effective prescription dose decreased by a factor of three. As expected, TUMOR 7 BEDVH did not significantly change as a function of radionuclide half-life but varied by 10% due to radionuclide dose distribution. Variations in reported radiobiological parameters caused TUMOR 7 BED 10 to deviate by up to 46%. Over the range of OAR α/β values, OAR 7 BED 10 varied by up to 41%, 3.1%, and 1.4% for the lens, optic nerve, and lacrimal gland, respectively. Conclusions: BEDVH permits evaluation of the

  12. Results on charm hadroproduction from CERN experiment WA82

    Energy Technology Data Exchange (ETDEWEB)

    Antinori, F.; Barberis, D.; Beusch, W.; Davenport, M.; Dufey, J.P.; French, B.R.; Harrison, K.; Jacholkowski, A.; Kirk, A.; Lamanna, E.; Lassalle, J.C.; Muller, F.; Redaelli, N.; Roda, C.; Weymann, M. (CERN, Geneva (Switzerland)); Forino, A.; Gessaroli, R.; Mazzanti, P.; Quareni, A.; Viaggi, F. (Dipartimento di Fisica and INFN, Bologna (Italy)); Anselmi, R.; Casanova, V.; Dameri, M.; Hurst, R.; Novelli, P.; Osculati, B.; Rossi, L.; Tomasini, G. (Dipartimento di Fisica and INFN, Genova (Italy)); Buys, A.; Grard, F.; Legros, P. (Universite de Mons-Hainaut and IISN, Mons (Belgium)); Adamovich, M.; Alexandrov, Y.; Kharlamov, S.; Nechaeva, P.; Zavertyaev, M. (Lebedev Physical Institute, Moscow (Russian Federation))

    1992-02-01

    Experiment WA82 has collected data from 1987 to 1989 with the [Omega][prime] spectrometer at the CERN SPS. The aim of WA82 was a high statistics study of charm hadroproduction, using a silicon microstrip vertex detector and an impact parameter trigger. Latest results on the nuclear dependence of charm production and on the [ital x][sub [ital F

  13. Biological in situ Dose Painting for Image-Guided Radiation Therapy Using Drug-Loaded Implantable Devices

    International Nuclear Information System (INIS)

    Cormack, Robert A.; Sridhar, Srinivas; Suh, W. Warren; D'Amico, Anthony V.; Makrigiorgos, G. Mike

    2010-01-01

    Purpose: Implantable devices routinely used for increasing spatial accuracy in modern image-guided radiation treatments (IGRT), such as fiducials or brachytherapy spacers, encompass the potential for in situ release of biologically active drugs, providing an opportunity to enhance the therapeutic ratio. We model this new approach for two types of treatment. Methods and Materials: Radiopaque fiducials used in IGRT, or prostate brachytherapy spacers ('eluters'), were assumed to be loaded with radiosensitizer for in situ drug slow release. An analytic function describing the concentration of radiosensitizer versus distance from eluters, depending on diffusion-elimination properties of the drug in tissue, was developed. Tumor coverage by the drug was modeled for tumors typical of lung stereotactic body radiation therapy treatments for various eluter dimensions and drug properties. Six prostate 125 I brachytherapy cases were analyzed by assuming implantation of drug-loaded spacers. Radiosensitizer-induced subvolume boost was simulated from which biologically effective doses for typical radiosensitizers were calculated in one example. Results: Drug distributions from three-dimensional arrangements of drug eluters versus eluter size and drug properties were tabulated. Four radiosensitizer-loaded fiducials provide adequate radiosensitization for ∼4-cm-diameter lung tumors, thus potentially boosting biologically equivalent doses in centrally located stereotactic body treated lesions. Similarly, multiple drug-loaded spacers provide prostate brachytherapy with flexible shaping of 'biologically equivalent doses' to fit requirements difficult to meet by using radiation alone, e.g., boosting a high-risk region juxtaposed to the urethra while respecting normal tissue tolerance of both the urethra and the rectum. Conclusions: Drug loading of implantable devices routinely used in IGRT provides new opportunities for therapy modulation via biological in situ dose painting.

  14. 75 FR 41762 - Safety Zone; Annual Kennewick, WA, Columbia Unlimited Hydroplane Races, Kennewick, WA

    Science.gov (United States)

    2010-07-19

    ...-AA00 Safety Zone; Annual Kennewick, WA, Columbia Unlimited Hydroplane Races, Kennewick, WA AGENCY..., Columbia Unlimited Hydroplane Races'' also known as the Tri-City Water Follies Hydroplane Races. The safety... power and responsibilities between the Federal Government and Indian tribes. Energy Effects We have...

  15. Gentamicin coating of plasma chemical oxidized titanium alloy prevents implant-related osteomyelitis in rats.

    Science.gov (United States)

    Diefenbeck, M; Schrader, C; Gras, F; Mückley, T; Schmidt, J; Zankovych, S; Bossert, J; Jandt, K D; Völpel, A; Sigusch, B W; Schubert, H; Bischoff, S; Pfister, W; Edel, B; Faucon, M; Finger, U

    2016-09-01

    Implant related infection is one of the most feared and devastating complication associated with the use of orthopaedic implant devices. Development of anti-infective surfaces is the main strategy to prevent implant contamination, biofilm formation and implant related osteomyelitis. A second concern in orthopaedics is insufficient osseointegration of uncemented implant devices. Recently, we reported on a macroporous titanium-oxide surface (bioactive TiOB) which increases osseointegration and implant fixation. To combine enhanced osseointegration and antibacterial function, the TiOB surfaces were, in addition, modified with a gentamicin coating. A rat osteomyelitis model with bilateral placement of titanium alloy implants was employed to analyse the prophylactic effect of gentamicin-sodiumdodecylsulfate (SDS) and gentamicin-tannic acid coatings in vivo. 20 rats were randomly assigned to four groups: (A) titanium alloy; PBS inoculum (negative control), (B) titanium alloy, Staphylococcus aureus inoculum (positive control), (C) bioactive TiOB with gentamicin-SDS and (D) bioactive TiOB plus gentamicin-tannic acid coating. Contamination of implants, bacterial load of bone powder and radiographic as well as histological signs of implant-related osteomyelitis were evaluated after four weeks. Gentamicin-SDS coating prevented implant contamination in 10 of 10 tibiae and gentamicin-tannic acid coating in 9 of 10 tibiae (infection prophylaxis rate 100% and 90% of cases, respectively). In Group (D) one implant showed colonisation of bacteria (swab of entry point and roll-out test positive for S. aureus). The interobserver reliability showed no difference in the histologic and radiographic osteomyelitis scores. In both gentamicin coated groups, a significant reduction of the histological osteomyelitis score (geometric mean values: C = 0.111 ± 0.023; D = 0.056 ± 0.006) compared to the positive control group (B: 0.244 ± 0.015; p < 0.05) was observed. The

  16. Healing of experimental femoral defects in rats after implantation of collagen-calcium phosphate biocomposites

    Directory of Open Access Journals (Sweden)

    O. V. Korenkov

    2017-06-01

    Full Text Available The aim of this study was to investigate the healing process of experimental defects of the femoral shaft diaphysis of rats after implantation of osteoplastic material Collapan into its cavity. In experi-mental animals, a perforated defect with diameter of 2.5 mm was created in the medullary canal of the femoral shaft and filled with osteoplastic material Collapan. In control rats, the defect was left un-filled. The bone fragments were examined on the 15th and 30th day by light microscopy morphometry and scanning electron microscopy. It was found that application of osteoplastic material Collapan in the femoral diaphysis defect optimised reparative osteogenesis, showed high biocompatibility, osteo-conductive properties, resorption ability and good integration with tissue-specific structures of the regenerate

  17. Biodegradable Magnesium (Mg) Implantation Does Not Impose Related Metabolic Disorders in Rats with Chronic Renal Failure

    Science.gov (United States)

    Wang, Jiali; Xu, Jiankun; Liu, Waiching; Li, Yangde; Qin, Ling

    2016-05-01

    Mg and its alloys have been considered as one of the most promising biodegradable medical devices, but it was still unclear whether hypermagnesemia involved health risks would occur in persons with kidney disease due to their deteriorated kidney function for Mg ions excretion from their body. In this study, we established a chronic renal failure (CRF) model in rats induced by adenine administration prior to Mg implantation, aiming to predict if CRF patients are suitable for the use of Mg implants. The results showed that Mg levels in serum, urine, feces and internal organs had no significant changes after Mg implantation for both normal and CRF rats. Biochemical indices detection and histopathological analysis in kidney, liver and heart tissue confirmed that Mg implants did not induce any extra damage in animals even with renal failure. Our study indicates that Mg based orthopaedic medical device may be considered for use in CRF patients without biosafety concerns.

  18. The synergistic effect of TiO2 nanoporous modification and platelet-rich plasma treatment on titanium-implant stability in ovariectomized rats

    Directory of Open Access Journals (Sweden)

    Jiang N

    2016-09-01

    Full Text Available Nan Jiang,1,2 Pinggong Du,2 Weidong Qu,2 Lin Li,2 Zhonghao Liu,2 Songsong Zhu1 1State Key Laboratory of Oral Diseases and Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, 2Yantai City Stomatological Hospital, Yantai, People’s Republic of China Abstract: For several decades, titanium and its alloys have been commonly utilized for endosseous implantable materials, because of their good mechanical properties, chemical resistance, and biocompatibility. But associated low bone mass, wear and loss characteristics, and high coefficients of friction have limited their long-term stable performance, especially in certain abnormal bone-metabolism conditions, such as postmenopausal osteoporosis. In this study, we investigated the effects of platelet-rich plasma (PRP treatment and TiO2 nanoporous modification on the stability of titanium implants in osteoporotic bone. After surface morphology, topographical structure, and chemical changes of implant surface had been detected by scanning electron microscopy (SEM, atomic force microscopy, contact-angle measurement, and X-ray diffraction, we firstly assessed in vivo the effect of PRP treatment on osseointegration of TiO2-modified implants in ovariectomized rats by microcomputed tomography examinations, histology, biomechanical testing, and SEM observation. Meanwhile, the potential molecular mechanism involved in peri-implant osseous enhancement was also determined by quantitative real-time polymerase chain reaction. The results showed that this TiO2-modified surface was able to lead to improve bone implant contact, while PRP treatment was able to increase the implant surrounding bone mass. The synergistic effect of both was able to enhance the terminal force of implants drastically in biomechanical testing. Compared with surface modification, PRP treatment promoted earlier osteogenesis with increased expression of the RUNX2 and COL1 genes and

  19. Novel Pathway of Salicylate Degradation by Streptomyces sp. Strain WA46

    OpenAIRE

    Ishiyama, Daisuke; Vujaklija, Dusica; Davies, Julian

    2004-01-01

    A novel salicylate-degrading Streptomyces sp., strain WA46, was identified by UV fluorescence on solid minimal medium containing salicylate; trace amounts of gentisate were detected by high-pressure liquid chromatography when strain WA46 was grown with salicylate. PCR amplification of WA46 DNA with degenerate primers for gentisate 1,2-dioxygenase (GDO) genes produced an amplicon of the expected size. Sequential PCR with nested GDO primers was then used to identify a salicylate degradation gen...

  20. Anatomy-based inverse planning dose optimization in HDR prostate implant: A toxicity study

    International Nuclear Information System (INIS)

    Mahmoudieh, Alireza; Tremblay, Christine; Beaulieu, Luc; Lachance, Bernard; Harel, Francois; Lessard, Etienne; Pouliot, Jean; Vigneault, Eric

    2005-01-01

    Background and purpose: The aim of this study is to evaluate the acute and late complications in patients who have received HDR implant boost using inverse planning, and to determine dose volume correlations. Patients and methods: Between September 1999 and October 2002, 44 patients with locally advanced prostate cancer (PSA ≥10 ng/ml, and/or Gleason score ≥7, and/or Stage T2c or higher) were treated with 40-45 Gy external pelvic field followed by 2-3 fraction of inverse-planned HDR implant boost (6-9.5 Gy /fraction). Median follow-up time was 1.7 years with 81.8% of patients who had at least 12 months of follow up (range 8.6-42.5. Acute and late morbidity data were collected and graded according to RTOG criteria. Questionnaires were used to collect prostate related measures of quality of life, and international prostate symptom score (IPSS) before and after treatment. Dose-volume histograms for prostate, urethra, bladder, penis bulb and rectum were analyzed. Results: The median patient age was 64 years. Of these, 32% were in the high risk group, and 61% in the intermediate risk group. 3 patients (7%) had no adverse prognostic factors. A single grade 3 GU acute toxicity was reported but no grade 3-4 acute GI toxicity. No grade 3-4 late GU or GI toxicity was reported. Acute (late) grade 2 urinary and rectal symptoms were reported in 31.8 (11.4%) and 4.6% (4.6%) of patients, respectively. A trend for predicting acute GU toxicity is seen for total HDR dose of more than 18 Gy (OR=3.6, 95%CI=[0.96-13.5], P=0.058). The evolution of toxicity is presented for acute and late GU/GI toxicity. Erectile dysfunction occurs in approximately 27% of patients who were not on hormonal deprivation, but may be taking sildenafil. The IPSS peaked on averaged 6 weeks post-implant and returned to the baseline at a median of 6 months. Conclusions: Inverse-planned HDR brachytherapy is a viable option to deliver higher dose to the prostate as a boost without increasing GU or rectal

  1. The use of polymer gel dosimetry to measure dose distribution around metallic implants

    International Nuclear Information System (INIS)

    Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa

    2014-01-01

    A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances. (author)

  2. [The use of polymer gel dosimetry to measure dose distribution around metallic implants].

    Science.gov (United States)

    Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa

    2014-10-01

    A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances.

  3. Titanium Implant Impairment and Surrounding Muscle Cell Death Following High-Salt Diet: An In Vivo Study.

    Directory of Open Access Journals (Sweden)

    Mathieu Lecocq

    Full Text Available High-salt consumption has been widely described as a risk factor for cardiovascular, renal and bone functions. In the present study, the extent to which high-salt diet could influence Ti6Al4V implant surface characteristic, its adhesion to rat tibial crest, and could modify muscle cell viability of two surrounding muscles, was investigated in vivo. These parameters have also been assessed following a NMES (neuro-myoelectrostimulation program similar to that currently used in human care following arthroplasty.After a three-week diet, a harmful effect on titanium implant surface and muscle cell viability was noted. This is probably due to salt corrosive effect on metal and then release of toxic substance around biologic tissue. Moreover, if the use of NMES with high-salt diet induced muscles damages, the latter were higher when implant was added. Unexpectedly, higher implant-to-bone adhesion was found for implanted animals receiving salt supplementation.Our in vivo study highlights the potential dangerous effect of high-salt diet in arthroplasty based on titanium prosthesis. This effect appears to be more important when high-salt diet is combined with NMES.

  4. Development of a radiochemical procedure for certification of phosphorus implantation dose in silicon

    International Nuclear Information System (INIS)

    Paul, R.L.; Simons, D.S.

    2002-01-01

    The U.S. semiconductor industry relies heavily on secondary ion mass spectrometry (SIMS) for characterization of the depth distribution of dopants such as boron, arsenic, and phosphorus in silicon. To assist the industry in achieving high accuracy measurements, two Standard Reference Materials (SRMs) have been developed by NIST as SIMS calibration standards: SRM 2137 (Boron Implant in Silicon), certified by neutron depth profiling, and SRM 2134 (Arsenic Implant in Silicon), certified by instrumental neutron activation analysis. The industry is still in need of a phosphorus standard. Plans are currently underway to develop a phosphorus implant in silicon SRM, to be certified by radiochemical neutron activation analysis (RNAA). RNAA was chosen because other techniques lack the necessary sensitivity, chemical specificity and matrix independence to measure phosphorus at implantation levels. In order to assess the sensitivity, accuracy, and precision of RNAA for this work, preliminary measurements were carried out on six pieces of a phosphorus-implanted silicon wafer that was previously used in a round-robin study of SIMS measurement repeatability. Standards were prepared by depositing micro litre amounts of a standardized phosphorus solution on aluminum foil. A non-implanted silicon wafer was analysed as a blank. Samples were irradiated at a neutron fluency rate of 1 x 10 14 cm -2 s -1 to convert 31 P to 32 P, then mixed with milligram amounts of phosphorus carrier and dissolved in a mixture of nitric and hydrofluoric acids. Phosphorus was separated from the matrix by precipitation first as ammonium phosphomolybdate then as magnesium ammonium phosphate. The yield (fraction of recovered carrier) was determined gravimetrically as Mg(NH 4 )PO 4 .6H 2 O. 32 P was measured using a beta proportional counter. The measurements yielded a mean and standard deviation of (8.35 ± 0.20) x 10 14 atoms.cm -2 (relative standard deviation = 2.35 %), in agreement with both the nominal

  5. RBS-study of GexSi1-x Compounds Formed by Variable Dose Ge Implantation into Si Wafers

    Directory of Open Access Journals (Sweden)

    Ramírez A.

    2002-01-01

    Full Text Available Amorphous and relaxed epitaxial GeSi films are prepared by Ge-implantation into Si(111 wafers of both 60 keV and 200 keV energetic Ge+-ions with appropriate dose, followed by post-implantation thermal annealing, comprising a single final annealing at a temperature of 900 °C. The implantation dose was varied between 10(14 and 10(17 atoms cm-2. Rutherford backscattering (RBS and channeling analysis was applied in order to explore the formation of a single crystalline Si-Ge compound layer, both prior and after the thermal treatment. The depth and the thickness of the implanted layer, as well as their molar composition and crystalline quality was determined, and it was found that a single crystalline Si-Ge alloy layer was created, with both depth and mole fraction depending on the ion energy and the ion dose.

  6. Results on charm hadroproduction from CERN experiment WA82

    International Nuclear Information System (INIS)

    Antinori, F.; Barberis, D.; Beusch, W.; Davenport, M.; Dufey, J.P.; French, B.R.; Harrison, K.; Jacholkowski, A.; Kirk, A.; Lamanna, E.; Lassalle, J.C.; Muller, F.; Redaelli, N.; Roda, C.; Weymann, M.; Forino, A.; Gessaroli, R.; Mazzanti, P.; Quareni, A.; Viaggi, F.; Anselmi, R.; Casanova, V.; Dameri, M.; Hurst, R.; Novelli, P.; Osculati, B.; Rossi, L.; Tomasini, G.; Buys, A.; Grard, F.; Legros, P.; Adamovich, M.; Alexandrov, Y.; Kharlamov, S.; Nechaeva, P.; Zavertyaev, M.

    1992-01-01

    Experiment WA82 has collected data from 1987 to 1989 with the Ω' spectrometer at the CERN SPS. The aim of WA82 was a high statistics study of charm hadroproduction, using a silicon microstrip vertex detector and an impact parameter trigger. Latest results on the nuclear dependence of charm production and on the x F distributions of D + and D - mesons are presented and discussed

  7. Effect of lipoprotein-associated phospholipase A2 inhibitor on insulin resistance in streptozotocin-induced diabetic pregnant rats.

    Science.gov (United States)

    Wang, Guo-Hua; Jin, Jun; Sun, Li-Zhou

    2018-06-21

    This paper aims to investigate the influence of lipoprotein-associated phospholipase A2 (Lp-PLA2) inhibitor, darapladib, on insulin resistance (IR) in streptozotocin (STZ)-induced diabetic pregnant rats. The rat models were divided into Control (normal pregnancy), STZ + saline (STZ-induced diabetic pregnant rats), STZ + Low-dose and STZ + High-dose darapladib (STZ-induced diabetic pregnant rats treated with low-/high-dose darapladib) groups. Pathological changes were observed by Hematoxylin-eosin (HE) and Immunohistochemistry staining. Lp-PLA2 levels were determined by enzyme-linked immunosorbent assay (ELISA). An automatic biochemical analyzer was used to measure the serum levels of biochemical indicators, and homeostatic model assessment for insulin resistance (HOMA-IR) and insulin sensitivity index (ISI) were calculated. Western blot was applied to determine levels of inflammatory cytokines. Compared with Control group, rats in the STZ + saline group were significantly decreased in body weight, the number of embryo implantation, the number of insulin positive cells and pancreatic islet size as well as the islet endocrine cells, and high-density lipoprotein (HDL-C) level, but substantially increased in Lp-PLA2, low-density lipoprotein (LDL-C), fatty acids (FFA), serum total cholesterol (TC), triglyceride (TG) levels. Moreover, the increased fasting plasma glucose (FPG) and HOMA-IR and inflammatory cytokines but decreased fasting insulin (FINS) and ISI were also found in diabetic pregnant rats. On the contrary, rats in the darapladib-treated groups were just opposite to the STZ + saline group, and STZ + High-dose group improved better than STZ + Low-dose group. Thus, darapladib can improve lipid metabolism, and enhance insulin sensitivity of diabetic pregnant rats by regulating inflammatory cytokines.

  8. A novel knee prosthesis model of implant-related osteo- myelitis in rats

    DEFF Research Database (Denmark)

    Søe, Niels H.; Jensen, Nina Vendel; Nürnberg, Birgit Meinecke

    2012-01-01

    There have been numerous reports of animal models of osteomyelitis. Very few of these have been prosthesis models that imitate human conditions. We have developed a new rat model of implant-related osteomyelitis that mimics human osteomyelitis, to investigate the pathology of infection after...

  9. Study of the boron levels in serum after implantation of different ratios nano-hexagonal boron nitride–hydroxy apatite in rat femurs

    Energy Technology Data Exchange (ETDEWEB)

    Atila, Alptug, E-mail: alptugatila@yahoo.com [Department of Analytical Chemistry, Faculty of Pharmacy, Ataturk University, Erzurum 25240 (Turkey); Halici, Zekai; Cadirci, Elif [Department of Pharmacology, Faculty of Medicine, Ataturk University, Erzurum 25240 (Turkey); Karakus, Emre [Department of Pharmacology and Toxicology, School of Veterinary Medicine, Ataturk University, Erzurum 25240 (Turkey); Palabiyik, Saziye Sezin [Department of Pharmaceutical Toxicology, Faculty of Pharmacy, Ataturk University, Erzurum 25240 (Turkey); Ay, Nuran [Department of Material Science and Engineering, Faculty of Engineering, Anadolu University, Eskisehir 26555 (Turkey); Bakan, Feray [Sabancı University Nanotechnology Research and Application Center (SUNUM), Istanbul 34956 (Turkey); Yilmaz, Sahin [Department of Genetics and Bioengineering, Faculty of Engineering and Architecture, Yeditepe University, Istanbul 34755 (Turkey)

    2016-01-01

    ABSTRACT: Boron and its derivatives are effective in bone recovery and osteointegration. However, increasing the boron levels in body liquids may cause toxicity. The aim of our study is to investigate serum boron levels using ICP-MS after implantation of different ratios of nano-hBN–HA composites in rat femurs. All rats were (n = 126) divided into five experimental groups (n = 24) and one healthy group (6 rats); healthy (Group1), femoral defect + %100HA (Group2), femoral defect + %2.5hBN + %97.5HA (Group3), femoral defect + %5hBN + %95HA (Group4), femoral defect + %10hBN + %90 HA (Group5), femoral defect + %100hBN (Group6). The femoral defect was created in the distal femur (3 mm drill-bit). Each implant group was divided into four different groups (n = 24) also 6 rats sacrificed for each groups in one week intervals during four weeks. In our results; at 1, 2, 3, and 4 weeks after implantation near bone tissue, serum levels of boron were evaluated using ICP-MS. We demonstrated that neither short-term nor long-term implantation of hBN–HA composite resulted in statistically increased serum boron levels in experimental groups compared to healthy group. In conclusion, this study investigated the implant material produced form hBN–HA for the first time. Our data suggest that hBN is a new promising target for biomaterial and implant bioengineers. - Highlights: • Nano-hBN–HA composites are new targets for biomaterial and implant bioengineers. • Serum boron levels were researched after implantation of nano-hBN–HA composites. • Implantation of hBN–HA composite did not result in increased serum boron levels. • The use of boron in composite form with HA did not change the stability of the implant.

  10. External fixation of femoral defects in athymic rats: Applications for human stem cell implantation and bone regeneration

    Directory of Open Access Journals (Sweden)

    Terasa Foo

    2013-01-01

    Full Text Available An appropriate animal model is critical for the research of stem/progenitor cell therapy and tissue engineering for bone regeneration in vivo. This study reports the design of an external fixator and its application to critical-sized femoral defects in athymic rats. The external fixator consists of clamps and screws that are readily available from hardware stores as well as Kirschner wires. A total of 35 rats underwent application of the external fixator with creation of a 6-mm bone defect in one femur of each animal. This model had been used in several separate studies, including implantation of collagen gel, umbilical cord blood mesenchymal stem cells, endothelial progenitor cells, or bone morphogenetic protein-2. One rat developed fracture at the proximal pin site and two rats developed deep tissue infection. Pin loosening was found in nine rats, but it only led to the failure of external fixation in two animals. In 8 to 10 weeks, various degrees of bone growth in the femoral defects were observed in different study groups, from full repair of the bone defect with bone morphogenetic protein-2 implantation to fibrous nonunion with collagen gel implantation. The external fixator used in these studies provided sufficient mechanical stability to the bone defects and had a comparable complication rate in athymic rats as in immunocompetent rats. The external fixator does not interfere with the natural environment of a bone defect. This model is particularly valuable for investigation of osteogenesis of human stem/progenitor cells in vivo.

  11. Implantable batteryless device for on-demand and pulsatile insulin administration

    Science.gov (United States)

    Lee, Seung Ho; Lee, Young Bin; Kim, Byung Hwi; Lee, Cheol; Cho, Young Min; Kim, Se-Na; Park, Chun Gwon; Cho, Yong-Chan; Choy, Young Bin

    2017-04-01

    Many implantable systems have been designed for long-term, pulsatile delivery of insulin, but the lifetime of these devices is limited by the need for battery replacement and consequent replacement surgery. Here we propose a batteryless, fully implantable insulin pump that can be actuated by a magnetic field. The pump is prepared by simple-assembly of magnets and constituent units and comprises a drug reservoir and actuator equipped with a plunger and barrel, each assembled with a magnet. The plunger moves to noninvasively infuse insulin only when a magnetic field is applied on the exterior surface of the body. Here we show that the dose is easily controlled by varying the number of magnet applications. Also, pump implantation in diabetic rats results in profiles of insulin concentration and decreased blood glucose levels similar to those observed in rats treated with conventional subcutaneous insulin injections.

  12. Monte Carlo simulations for dose enhancement in cancer treatment using bismuth oxide nanoparticles implanted in brain soft tissue.

    Science.gov (United States)

    Taha, Eslam; Djouider, Fathi; Banoqitah, Essam

    2018-03-26

    The objective of this work is to study the dosimetric performances of bismuth oxide nanoparticles implanted in tumors in cancer radiotherapy. GEANT4 based Monte Carlo numerical simulations were performed to assess dose enhancement distributions in and around a 1 × 1 × 1 cm 3 tumor implanted with different concentrations of bismuth oxide and irradiated with low energies 125 I, 131 Cs, and 103 Pd radioactive sources. Dose contributions were considered from photoelectrons, Auger electrons, and characteristic X-rays. Our results show the dose enhancement increased with increasing both bismuth oxide concentration in the target and photon energy. A dose enhancement factor up to 18.55 was obtained for a concentration of 70 mg/g of bismuth oxide in the tumor when irradiated with 131 Cs source. This study showed that bismuth oxide nanoparticles are innovative agents that could be potentially applicable to in vivo cancer radiotherapy due to the fact that they induce a highly localized energy deposition within the tumor.

  13. A magnetic resonance imaging study on changes in rat mandibular bone marrow and pulp tissue after high-dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wan; Lee, Byung Do [Dept. of Oral and Maxillofacial Radiology and Wonkwang Dental Research Institute, College of Dentistry, Wonkwang University, Iksan (Korea, Republic of); Lee, Kang Kyoo [Dept. of Radiation Oncology, School of Medicine, Wonkwang University, Iksan (Korea, Republic of); Koh, Kwang Joon [Dept. of Oral and Maxillofacial Radiology, School of Dentistry and Institute of Oral Bioscience, Chonbuk National University, Jeonju (Korea, Republic of)

    2014-03-15

    This study was designed to evaluate whether magnetic resonance imaging (MRI) is appropriate for detecting early changes in the mandibular bone marrow and pulp tissue of rats after high-dose irradiation. The right mandibles of Sprague-Dawley rats were irradiated with 10 Gy (Group 1, n=5) and 20 Gy (Group 2, n=5). Five non-irradiated animals were used as controls. The MR images of rat mandibles were obtained before irradiation and once a week until week 4 after irradiation. From the MR images, the signal intensity (SI) of the mandibular bone marrow and pulp tissue of the incisor was interpreted. The MR images were compared with the histopathologic findings. The SI of the mandibular bone marrow had decreased on T2-weighted MR images. There was little difference between Groups 1 and 2. The SI of the irradiated groups appeared to be lower than that of the control group. The histopathologic findings showed that the trabecular bone in the irradiated group had increased. The SI of the irradiated pulp tissue had decreased on T2-weighted MR images. However, the SI of the MR images in Group 2 was high in the atrophic pulp of the incisor apex at week 2 after irradiation. These patterns seen on MRI in rat bone marrow and pulp tissue were consistent with histopathologic findings. They may be useful to assess radiogenic sclerotic changes in rat mandibular bone marrow.

  14. Dose-dependent effect of ghrelin on gastric emptying in rats and the related mechanism of action

    Directory of Open Access Journals (Sweden)

    Shu-Guang Cao

    2016-03-01

    Full Text Available The aim of this study was to investigate the dose-dependent effect of ghrelin on gastric emptying in rats and the related mechanism of action. Sixty Wistar rats were randomized into control and test groups, which respectively received intraperitoneal injection of normal saline and ghrelin at different doses (0.5 nmol/kg, 1.0 nmol/kg, 1.5 nmol/kg, 2.0 nmol/kg, and 2.5 nmol/kg. After 45 minutes, all rats were gavaged with semisolid paste. The gastric emptying rate was determined 30 minutes later, and the plasma cholecystokinin level was tested by radioimmunoassay. The mean gastric emptying rate in the test groups was significantly higher than in the control group (38.24 ± 7.15% and 27.18 ± 2.37%, respectively, p < 0.05. Medium and high doses of ghrelin (1.0 nmol/kg, 1.5 nmol/kg, 2.0 nmol/kg, and 2.5 nmol/kg, but not low dose (0.5 nmol/kg, accelerated the gastric emptying. In addition, the plasma cholecystokinin level in the test groups was significantly higher than in the control group (p < 0.01. The gastric emptying rate was positively correlated with the plasma cholecystokinin level (p < 0.01. Intraperitoneal injection of ghrelin at medium and high doses significantly accelerated gastric emptying in rats.

  15. Growth of extrapulmonary tumours after inhalation of small doses of plutonium oxide by rats

    International Nuclear Information System (INIS)

    Nolibe, D.; Masse, R.; L'Hullier, I.; Metivier, H.; Lafuma, J.

    1983-01-01

    After inhalation of plutonium oxide ( 239 PuO 2 ) involving initial lung burdens ranging from 74 to 103 Bq, male rats of the Wistar strain are kept in conditions allowing maximum survival; tumour incidences for the target organ (lung) and for the rest of the organs are calculated separately after the death of the animals. In the outbred Wistar rat the incidence of lung tumours is 18.5% for an initial lung burden of 74 Bq. The mean survival time of animals having such tumours is 973 days after inhalation. For an initial burden of 103 Bq syngenetic Wistar AG rats show a lower frequency of lung tumours (6.1%), but also a much reduced mean survival time, namely 757 days. Compared with the frequencies observed in the corresponding control groups, the frequency of non-pulmonary tumours is twice as high (12%) in consanguineous rats and six times as high (25.9%) in conventional rats. A supralinear dose-effect relationship at very low doses seems improbable in view of the dose delivered ( -3 Gy in the most exposed organs, such as the liver) and, in particular, because there is no correlation between the dose delivered to the organs and the location of the tumours. The exposed animals show, on the one hand, no specificity of organs for the surplus extrapulmonary tumours observed, and on the other, an inhibition by about 45% in the natural cytotoxic activity (natural killers) measured one year after inhalation. These observations suggest the hypothesis that an anti-tumour control mechanism is affected, perhaps as a result of the irradiation experienced during the circulation of blood cells in the lung capillaries. The failure of this system would in that case allow the expression of neoplastic characters as ageing progresses. A non-specific BCG immunotherapy does not restore this anti-tumour control system. (author)

  16. Optical effects of ion implantation

    International Nuclear Information System (INIS)

    Townsend, P.D.

    1987-01-01

    The review concerns the effects of ion implantation that specifically relate to the optical properties of insulators. Topics which are reviewed include: ion implantation, ion range and damage distributions, colour centre production by ion implantation, high dose ion implantation, and applications for integrated optics. Numerous examples are presented of both diagnostic and industrial examples of ion implantation effects in insulators. (U.K.)

  17. Lithium chloride enhances bone regeneration and implant osseointegration in osteoporotic conditions.

    Science.gov (United States)

    Jin, Yifan; Xu, Lihua; Hu, Xiaohui; Liao, Shixian; Pathak, Janak L; Liu, Jinsong

    2016-10-06

    Osteoporotic patients have a high risk of dental and orthopedic implant failure. Lithium chloride (LiCl) has been reported to enhance bone formation. However, the role of LiCl in the success rate of dental and orthopedic implants in osteoporotic conditions is still unknown. We investigated whether LiCl enhances implant osseointegration, implant fixation, and bone formation in osteoporotic conditions. Sprague-Dawley female rats (n = 18) were ovariectomized (OVX) to induce osteoporosis, and another nine rats underwent sham surgery. Three months after surgery, titanium implants were implanted in the tibia of the OVX and sham group rats. After implantation, the OVX rats were gavaged with 150 mg/kg/2 days of LiCl (OVX + LiCl group) or saline (OVX group), and sham group rats were gavaged with saline for 3 months. Implant osseointegration and bone formation were analyzed using histology, biomechanical testing, and micro computed tomography (micro-CT). More bone loss was observed in the OVX group compared to the control, and LiCl treatment enhanced bone formation and implant fixation in osteoporotic rats. In the OVX group, bone-implant contact (BIC) was decreased by 81.2 % compared to the sham group. Interestingly, the OVX + LiCl group showed 4.4-fold higher BIC compared to the OVX group. Micro-CT data of tibia from the OVX + LiCl group showed higher bone volume, trabecular thickness, trabecular number, and osseointegration compared to the OVX group. Maximum push-out force and implant-bone interface shear strength were 2.9-fold stronger in the OVX + LiCl group compared to the OVX group. In conclusion, LiCl enhanced implant osseointegration, implant fixation, and bone formation in osteoporotic conditions, suggesting LiCl as a promising therapeutic agent to prevent implant failure and bone loss in osteoporotic conditions.

  18. Effect of acclimation to caging on nephrotoxic response of rats to uranium.

    Science.gov (United States)

    Damon, E G; Eidson, A F; Hobbs, C H; Hahn, F F

    1986-02-01

    Animal studies of the toxicity and metabolism of radionuclides and chemicals often require housing of rats in metabolism cages for excreta collection. Response of rats to toxic substances may be affected by environmental factors such as the type of cage used. Dose-response studies were conducted to assess the effects of two types of cages on the nephrotoxic response of rats to uranium from implanted refined uranium ore (yellowcake). The LD50/21 days was 6 mg of uranium ore per kilogram body weight (6 mg U/kg). The 95% confidence limit (C.L.) was 3-8 mg U/kg for rats housed in metabolism cages beginning on the day of implantation (naive rats). However, for rats housed in metabolism cages for 21 days before implantation (acclimated rats) the LD50/21 days was 360 mg U/kg (95% C.L. = 220-650 mg U/kg), which was the same value obtained for rats housed continuously in polycarbonate cages. This significant difference (P less than 0.01) in response of naive rats compared to response of acclimated rats appeared related to a significantly lower water consumption by the naive rats.

  19. Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Luerman, Christine M.; Sowards, Keith T.

    2009-01-01

    Recently, several different models of 125 I and 103 Pd brachytherapy sources have been introduced in order to meet the increasing demand for prostate seed implants. These sources have different internal structures; hence, their TG-43 dosimetric parameters are not the same. In this study, the effects of the dosimetric differences among the sources on their clinical applications were evaluated. The quantitative and qualitative evaluations were performed by comparisons of dose distributions and dose volume histograms of prostate implants calculated for various designs of 125 I and 103 Pd sources. These comparisons were made for an identical implant scheme with the same number of seeds for each source. The results were compared with the Amersham model 6711 seed for 125 I and the Theragenics model 200 seed for 103 Pd using the same implant scheme.

  20. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  1. Polyethylene glycol hydrogel rectal spacer implantation in patients with prostate cancer undergoing combination high-dose-rate brachytherapy and external beam radiotherapy.

    Science.gov (United States)

    Yeh, Jekwon; Lehrich, Brandon; Tran, Carolyn; Mesa, Albert; Baghdassarian, Ruben; Yoshida, Jeffrey; Torrey, Robert; Gazzaniga, Michael; Weinberg, Alan; Chalfin, Stuart; Ravera, John; Tokita, Kenneth

    2016-01-01

    To present rectal toxicity rates in patients administered a polyethylene glycol (PEG) hydrogel rectal spacer in conjunction with combination high-dose-rate brachytherapy and external beam radiotherapy. Between February 2010 and April 2015, 326 prostate carcinoma patients underwent combination high-dose-rate brachytherapy of 16 Gy (average dose 15.5 Gy; standard deviation [SD] = 1.6 Gy) and external beam radiotherapy of 59.4 Gy (average dose 60.2 Gy; SD = 2.9 Gy). In conjunction with the radiation therapy regimen, each patient was injected with 10 mL of a PEG hydrogel in the anterior perirectal fat space. The injectable spacer (rectal spacer) creates a gap between the prostate and the rectum. The rectum is displaced from the radiation field, and rectal dose is substantially reduced. The goal is a reduction in rectal radiation toxicity. Clinical efficacy was determined by measuring acute and chronic rectal toxicity using the National Cancer Center Institute Common Terminology Criteria for Adverse Events v4.0 grading scheme. Median followup was 16 months. The mean anterior-posterior separation achieved was 1.6 cm (SD = 0.4 cm). Rates of acute Grade 1 and 2 rectal toxicity were 37.4% and 2.8%, respectively. There were no acute Grade 3/4 toxicities. Rates of late Grade 1, 2, and 3 rectal toxicity were 12.7%, 1.4%, and 0.7%, respectively. There were no late Grade 4 toxicities. PEG rectal spacer implantation is safe and well tolerated. Acute and chronic rectal toxicities are low despite aggressive dose escalation. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  2. High energy ion implantation

    International Nuclear Information System (INIS)

    Ziegler, J.F.

    1985-01-01

    High energy ion implantation offers the oppertunity for unique structures in semiconductor processing. The unusual physical properties of such implantations are discussed as well as the special problems in masking and damage annealing. A review is made of proposed circuit structures which involve deep implantation. Examples are: deep buried bipolar collectors fabricated without epitaxy, barrier layers to reduce FET memory sensitivity to soft-fails, CMOS isolation well structures, MeV implantation for customization and correction of completed circuits, and graded reach-throughs to deep active device components. (orig.)

  3. Thermal migration of iron implanted in aluminium at high doses

    International Nuclear Information System (INIS)

    Asundi, V.K.; Joshi, M.C.; Deb, S.K.; Soud, D.K.; Kulkarni, V.N.; Sundararaman, M.

    1978-01-01

    The anneal behaviour of the Fe-Al metastable system produced by implantation of Fe + ions at 30 keV has been reported. The implant concentrations between 18-42 at percent have been chosen, in order to exceed the normal solid solubility of Fe in Al by about three orders of magnitude. Isothermal annealing has been done under vacuum (55 x 10 -6 Torr) at 400deg C and 570 deg C. The iron depth profiles have been determined, by Rutherford backscattering of 2 MeV He + ions. It has been found that 1) as annealing proceeds, all specimens show rapid enhanced diffusion initially (upto about 30 m), followed by a much slower diffusion as iron ions migrate inwards (2) at implant concentrations 23 at percent, double peaks appear in iron depth profiles, followed by rapid migration of diffused iron towards surface and (3) at still higher anneal times, the out-diffused iron moves inward again. This kind of out-diffusion behaviour in a metallic system has not been reported earlier in the literature. Also, the presence of Fe 4 Al 13 has been identified as terminal phase, using x-ray diffraction techniques. (K.B.)

  4. Conditioned instrumental behaviour in the rat: Effects of prenatal irradiation with various low dose-rate doses. Instrumentelle Verhaltensuntersuchungen an der Ratte: Ueber die Wirkung verschiedener Dosen einer praenatalen Bestrahlung niedriger Dosisleistung

    Energy Technology Data Exchange (ETDEWEB)

    Klug, H.

    1986-01-01

    4 groups of rats of the Wistar-strain were subjected to ..gamma..-irradiation on the 16th day of gestation. 5 rats received 0,6 Gy low dose rate irradiation, 5 animals received 0,9 Gy low dose and 6 high dose irradiation, 3 females were shamirradiated. The male offspring of these 3 irradiation groups and 1 control group were tested for locomotor coordination on parallel bars and in a water maze. The female offspring were used in an operant conditioning test. The locomotor test showed slight impairment of locomotor coordination in those animals irradiated with 0,9 Gy high dose rate. Swimming ability was significantly impaired by irradiation with 0,9 Gy high dose rate. Performance in the operant conditioning task was improved by irradiation with 0,9 Gy both low and high dose rate. The 0,9 Gy high dose rate group learned faster than all the other groups. For the dose of 0,9 Gy a significant dose rate effect could be observed. For the dose of 0,6 Gy a similar tendency was observed, differences between 0,6 Gy high and low dose rate and controls not being significant.

  5. Acute and developmental toxicity assessment of erincine A-enriched Hericium erinaceus mycelia in Sprague-Dawley rats.

    Science.gov (United States)

    Li, I-Chen; Chen, Wan-Ping; Chen, Yen-Po; Lee, Li-Ya; Tsai, Yueh-Ting; Chen, Chin-Chu

    2018-01-23

    This study aimed to establish an in vitro model to confirm the efficacy of erinacine A-enriched Hericium erinaceus (EAHE) mycelia and investigate its potential adverse effects in a preclinical experimental setting, including an assessment on the oral administration of EAHE mycelia in acute and prenatal developmental toxicity tests. At a single dose of 5000 mg/kg body weight, EAHE mycelia elicited no death or treatment-related signs of toxicity in ten Sprague-Dawley rats of both sexes during the 14 days of the experimental period. After considering the recommended dose range of EAHE mycelia from the acute toxicity test as well as the therapeutic doses, EAHE mycelia was administered to 66 pregnant rats in the low, medium, and high-dose groups by gavage at 875, 1750, and 2625 mg/kg body weight, respectively. All dams were subjected to a Caesarean section on the 20th day of pregnancy, and the fetuses were examined for any morphological abnormalities. Results indicated that weight of uterus, fetal body weight, number of corpora lutea, implantation sites, pre-implantation loss, and post-implantation loss of the treatment groups and the control group exhibited no statistical difference. In addition, no significant differences were observed in the fetal external, organ, and skeletal examinations. Taken together, it can be concluded that EAHE mycelia is considered safe and practically nontoxic for consumption within the appropriate doses and investigation period in this study.

  6. Effect of Ion Flux (Dose Rate) in Source-Drain Extension Ion Implantation for 10-nm Node FinFET and Beyond on 300/450mm Platforms

    Science.gov (United States)

    Shen, Ming-Yi

    The improvement of wafer equipment productivity has been a continuous effort of the semiconductor industry. Higher productivity implies lower product price, which economically drives more demand from the market. This is desired by the semiconductor manufacturing industry. By raising the ion beam current of the ion implanter for 300/450mm platforms, it is possible to increase the throughput of the ion implanter. The resulting dose rate can be comparable to the performance of conventional ion implanters or higher, depending on beam current and beam size. Thus, effects caused by higher dose rate must be investigated further. One of the major applications of ion implantation (I/I) is source-drain extension (SDE) I/I for the silicon FinFET device. This study investigated the dose rate effects on the material properties and device performance of the 10-nm node silicon FinFET. In order to gain better understanding of the dose rate effects, the dose rate study is based on Synopsys Technology CAD (TCAD) process and device simulations that are calibrated and validated using available structural silicon fin samples. We have successfully shown that the kinetic monte carlo (KMC) I/I simulation can precisely model both the silicon amorphization and the arsenic distribution in the fin by comparing the KMC simulation results with TEM images. The results of the KMC I/I simulation show that at high dose rate more activated arsenic dopants were in the source-drain extension (SDE) region. This finding matches with the increased silicon amorphization caused by the high dose-rate I/I, given that the arsenic atoms could be more easily activated by the solid phase epitaxial regrowth process. This increased silicon amorphization led to not only higher arsenic activation near the spacer edge, but also less arsenic atoms straggling into the channel. Hence, it is possible to improve the throughput of the ion implanter when the dopants are implanted at high dose rate if the same doping level

  7. Highly active antiretroviral therapy during gestation: effects on a rat model of pregnancy.

    Science.gov (United States)

    Carvalho, L P F; Simões, R S; Araujo Júnior, E; Oliveira Filho, R M; Kulay Júnior, L; Nakamura, M U

    2014-04-01

    To assess the adverse effects of the chronic use of zidovudine/lopinavir/ritonavir in a rat pregnancy model.Type of article: Original paper. A prospective experimental study. Department of Obstetrics, São Paulo Federal University (UNIFESP). 40 pregnant EPM-1 albino rats were randomly allocated into four groups of 10 animals each: control (Ctrl) group (untreated) and three experimental groups (Exp1, Exp2 and Exp3), which received zidovudine/lopinavir/ritonavir in the corresponding doses of 10/13.3/3.3; 30/39.9/9.9 and 90/119.7/29.7 mg/Kg/day from the first up to the 20th day of pregnancy, respectively. The rats were treated by gavage daily. Body weights were recorded on days 0, 7, 14 and 20. At term, the rats were sacrificed and the implantation sites, number of live and dead fetuses and placentas, resorptions and fetal and placental weights were recorded. The fetuses were evaluated for external abnormalities under a stereomicroscope. The chi-square test was used to compare death rates between groups. Weight gain during pregnancy no showed significant differences between groups. Average weight gains between the 7th and 20th day were 45.70 ± 5.27 g for Ctrl; 48.49 ± 3.64 g for Exp1; 45.39 ± 6.22 g for Exp2 and 44.19 ± 6.78 g for Exp3. However, the percentage weight gain in the 7th was lower in groups Exp2 and Exp3 and in the 14th in the Group Exp2. All other parameters assessed did not differ significantly between groups. Exp2 and Exp3 in relation of the others. The chronic exposure of pregnant rats to high doses of zidovudine/lopinavir/ritonavir in association resulted in a significant reduction in maternal body weight gain but was not associated with significant adverse fetal parameters.

  8. Behavior of PET implanted by Ti, Ag, Si and C ion using MEVVA implantation

    International Nuclear Information System (INIS)

    Wu Yuguang; Zhang Tonghe; Zhang Yanwen; Zhang Huixing; Zhang Xiaoji; Zhou Gu

    2001-01-01

    Polyethylene terephthalane (PET) has been modified with Ti, Ag, Si and C ions from a metal vapor arc source (MEVVA). Ti, Ag, Si and C ions were implanted with acceleration voltage 40 kV to fluences ranging from 1x10 16 to 2x10 17 cm -2 . The surface of implanted PET darkened with increasing ion dose, when the metal ion dose was greater than 1x10 17 cm -2 the color changed to metallic bright. The surface resistance decreases by 5-6 orders of magnitude with increasing dose. The resistivity is stable after long-term storage. The depth of Ti- and Ag-implanted layer is approximately 150 and 80 nm measured by Rutherford backscattering (RBS), respectively. TEM photos revealed the presence of Ti and Ag nano-meter particles on the surface resulting from the high-dose implantation. Ti and Ag ion implantations improved conductivity and wear resistance significantly. The phase and structural changes were obtained by X-ray diffraction (XRD). It can be seen that nano-meter particles of Ti precipitation, TiO 2 and Ti-carbides have been formed in implanted layer. Nano-hardness of implanted PET has been measured by a nano-indenter. The results show that the surface hardness, modulus and wear resistance could be increased

  9. The effect of therapeutic ultrasound on metallic implants: a study in rats.

    Science.gov (United States)

    Kocaoğlu, Barış; Cabukoglu, Cengiz; Ozeras, Nadire; Seyhan, Mustafa; Karahan, Mustafa; Yalcin, Selim

    2011-11-01

    To investigate whether therapeutic ultrasound (US) use over metallic implants has the potential for adverse effects as a result of greater temperature increases at the tissue-metal interface. A randomized controlled trial. A research laboratory. Sprague-Dawley rats (N=40; weight, 230-300g) were used and divided into 3 study groups. In group 1, both limbs of 10 rats were used for evaluation of temperature changes. Metal pins were placed into the femur of the left limb, and the right limbs were used as controls. A thermal sensor was placed into the medulla to record the elevation of tissue temperature during US application. In groups 2 and 3 with 15 rats in each, a midshaft femoral fracture was produced, and intramedullary fixation was performed with metal pins. Group 2 received US treatment for 5 minutes daily and continued for 27 days. Group 3 served as controls. The rats in groups 2 and 3 were killed on postoperative day 30. The specimens were evaluated by radiology, histopathology, and biomechanics. The presence of metal in bone did not cause an increased temperature rise. US application did not increase or decrease callus formation, and there was no tissue necrosis. The average removal torques of pins in groups did not show a significant difference. Internal fixation with metallic implants may not be a contraindication for therapeutic US treatment. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. Diethylene glycol-induced toxicities show marked threshold dose response in rats

    Energy Technology Data Exchange (ETDEWEB)

    Landry, Greg M., E-mail: Landry.Greg@mayo.edu [Department of Pharmacology, Toxicology, & Neuroscience, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Dunning, Cody L., E-mail: cdunni@lsuhsc.edu [Department of Pharmacology, Toxicology, & Neuroscience, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Abreo, Fleurette, E-mail: fabreo@lsuhsc.edu [Department of Pathology, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Latimer, Brian, E-mail: blatim@lsuhsc.edu [Department of Pharmacology, Toxicology, & Neuroscience, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Orchard, Elysse, E-mail: eorcha@lsuhsc.edu [Department of Pharmacology, Toxicology, & Neuroscience, Louisiana State University Health Sciences Center, Shreveport, LA (United States); Division of Animal Resources, Louisiana State University Health Sciences Center, Shreveport, LA (United States); McMartin, Kenneth E., E-mail: kmcmar@lsuhsc.edu [Department of Pharmacology, Toxicology, & Neuroscience, Louisiana State University Health Sciences Center, Shreveport, LA (United States)

    2015-02-01

    Diethylene glycol (DEG) exposure poses risks to human health because of widespread industrial use and accidental exposures from contaminated products. To enhance the understanding of the mechanistic role of metabolites in DEG toxicity, this study used a dose response paradigm to determine a rat model that would best mimic DEG exposure in humans. Wistar and Fischer-344 (F-344) rats were treated by oral gavage with 0, 2, 5, or 10 g/kg DEG and blood, kidney and liver tissues were collected at 48 h. Both rat strains treated with 10 g/kg DEG had equivalent degrees of metabolic acidosis, renal toxicity (increased BUN and creatinine and cortical necrosis) and liver toxicity (increased serum enzyme levels, centrilobular necrosis and severe glycogen depletion). There was no liver or kidney toxicity at the lower DEG doses (2 and 5 g/kg) regardless of strain, demonstrating a steep threshold dose response. Kidney diglycolic acid (DGA), the presumed nephrotoxic metabolite of DEG, was markedly elevated in both rat strains administered 10 g/kg DEG, but no DGA was present at 2 or 5 g/kg, asserting its necessary role in DEG-induced toxicity. These results indicate that mechanistically in order to produce toxicity, metabolism to and significant target organ accumulation of DGA are required and that both strains would be useful for DEG risk assessments. - Highlights: • DEG produces a steep threshold dose response for kidney injury in rats. • Wistar and F-344 rats do not differ in response to DEG-induced renal injury. • The dose response for renal injury closely mirrors that for renal DGA accumulation. • Results demonstrate the importance of DGA accumulation in producing kidney injury.

  11. Dose- dependent ameliorative effects of quercetin and l-Carnitine against atrazine- induced reproductive toxicity in adult male Albino rats.

    Science.gov (United States)

    Abdel Aziz, Rabie L; Abdel-Wahab, Ahmed; Abo El-Ela, Fatma I; Hassan, Nour El-Houda Y; El-Nahass, El-Shaymaa; Ibrahim, Marwa A; Khalil, Abdel-Tawab A Y

    2018-06-01

    This study aimed to determine the protective effects of co-administration of Quercetin (QT) or l-Carnitine (LC) against the oxidative stress induced by Atrazine (ATZ) in the reproductive system of intact male Albino rats. 36 rats were divided equally into 6 groups. Rats in the control negative "CNT" group received 1.5 ml distilled water for 21 days. All rats in the other groups received ATZ (120 mg/kg bw) through gavage. Groups 3 and 4 were co-administered with either low or high dose of QT (10 "ATZLQT" and 50 "ATZHQT" mg/kg bw, respectively). Groups 5 and 6 were co-administered with either low or high dose of LC (200 "ATZLLC" and 400 "ATZHLC" mg/kg bw, respectively). At the end of the experiment, animals were sacrificed and all samples were collected. ATZ significantly increased serum level of malondialdehyde (MDA) and decreased total antioxidant capacity (TAC). Also, ATZ increased significantly the sperm cell abnormalities and reduced both testicular IgA and serum testosterone levels. Testicular DNA laddering % and CYP17A1 mRNA expression were significantly reduced in ATZ group. Interestingly, co-administration with low dose QT or different doses of LC succeeded to counteract the negative toxic effects of ATZ on serum oxidative stress indicators, serum testosterone levels, testicular IgA level and improved testicular CYP17A1 mRNA expression. In conclusion, QT in low dose and LC in both low and high doses exerted a significant protective action against the reproductive toxicity of ATZ, while higher dose of QT failed induce immune-stimulant effect against ATZ in adult male Albino rats. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  12. Maximization of DRAM yield by control of surface charge and particle addition during high dose implantation

    Science.gov (United States)

    Horvath, J.; Moffatt, S.

    1991-04-01

    Ion implantation processing exposes semiconductor devices to an energetic ion beam in order to deposit dopant ions in shallow layers. In addition to this primary process, foreign materials are deposited as particles and surface films. The deposition of particles is a major cause of IC yield loss and becomes even more significant as device dimensions are decreased. Control of particle addition in a high-volume production environment requires procedures to limit beamline and endstation sources, control of particle transport, cleaning procedures and a well grounded preventative maintenance philosophy. Control of surface charge by optimization of the ion beam and electron shower conditions and measurement with a real-time charge sensor has been effective in improving the yield of NMOS and CMOS DRAMs. Control of surface voltages to a range between 0 and -20 V was correlated with good implant yield with PI9200 implanters for p + and n + source-drain implants.

  13. Methamphetamine treatment during development attenuates the dopaminergic deficits caused by subsequent high-dose methamphetamine administration

    OpenAIRE

    McFadden, Lisa M; Hoonakker, Amanda J; Vieira-Brock, Paula L; Stout, Kristen A; Sawada, Nicole M; Ellis, Jonathan D; Allen, Scott C; Walters, Elliot T; Nielsen, Shannon M; Gibb, James W; Alburges, Mario E; Wilkins, Diana G; Hanson, Glen R; Fleckenstein, Annette E

    2011-01-01

    Administration of high doses of methamphetamine (METH) causes persistent dopaminergic deficits in both nonhuman preclinical models and METH-dependent persons. Noteworthy, adolescent (i.e., postnatal day (PND) 40) rats are less susceptible to this damage than young adult (PND90) rats. In addition, biweekly treatment with METH, beginning at PND40 and continuing throughout development, prevents the persistent dopaminergic deficits caused by a “challenge” high-dose METH regimen when administered ...

  14. Alveolar wound healing after implantation with a pool of commercially available bovine bone morphogenetic proteins (BMPs): a histometric study in rats.

    Science.gov (United States)

    Calixto, Romeu Felipe Elias; Teófilo, Juliana Mazzonetto; Brentegani, Luiz Guilherme; Lamano-Carvalho, Teresa Lúcia

    2007-01-01

    The capacity of a commercially available pool of bovine bone morphogenetic proteins (BMPs) to stimulate osteogenesis in the rat alveolar healing was investigated by histometric analysis. Male rats were anesthetized and had their upper incisor extracted. A pool of purified bovine BMPs adsorbed to microgranular resorbable hydroxyapatite was agglutinated with bovine collagen and saline before implantation into the alveolar socket. The implanted and control rats (n=30 per group) were sacrificed 1 to 9 weeks postoperatively, the hemi-maxillae were decalcified, processed for paraffin embedding and semi-serial longitudinal sections were obtained and stained with hematoxylin and eosin. The volume fraction of alveolar healing components was estimated by a differential point-counting method in histologic images. The results showed that in both, control and implanted rats, the alveolar healing followed the histologic pattern usually described in the literature. Quantitative data confirmed that the BMPs mixture did not stimulate new bone formation in the alveolar socket of implanted rats. These results suggest that the pool of BMPs adsorbed to hydroxyapatite and agglutinated with bovine collagen did not warrant incorporation of the osteoinductive proteins to a slow-absorption system that would allow a BMPs release rate compatible to that of new bone formation, and thus more adequate to osteoinduction.

  15. Performance of rats orogastrically dosed with faecal strains of ...

    African Journals Online (AJOL)

    Albino rats (Rattus norvegicus) were orogastrically dosed with faecal strains of Lactobacillus acidophilus and simultaneously infected with Escherichia coli, while the control was challenged with E. coli alone. The treatment was repeated the second day and post ingestion period of 18 days follow. It was observed that rats ...

  16. The role of the substrate in the high energy boron implantation damage recovering

    International Nuclear Information System (INIS)

    Mica, I.; Di Piazza, L.; Laurin, L.; Mariani, M.; Mauri, A.G.; Polignano, M.L.; Ricci, E.; Sammiceli, F.; Spoldi, G.

    2009-01-01

    In this work the role of the Si substrate in the high energy boron implantation damage recovering is studied. The boron implants were carried out in Czochralski grown (1 0 0) polished Si substrates as well as in epitaxial Si layers grown on (1 0 0) Si by chemical vapor deposition. The boron implantation dose was 2 x 10 14 cm -2 and the implantation energy was 600 keV. The recovery annealing was a furnace annealing at 1000 deg. C for 40 min. The defects formed by high energy boron implantation have been observed with transmission electron microscopy (TEM). In order to increase the statistics some junctions were formed on the buried p-well and electrically characterized. For the epitaxial wafers it was found that the number and the size of the dislocations change according to the doping of the substrate. For the Czochralski wafers it was found that the morphology and the size of the dislocations change according to the presence of the wafer pre-annealing (whether conventional furnace annealing or Magic Denuded Zone process).

  17. Dose-volume effects in the rat cervical spinal cord after proton irradiation

    International Nuclear Information System (INIS)

    Bijl, Hendrik P.; Vuijk, Peter van; Coppes, Rob P.; Schippers, Jacobus M.; Konings, Antonius W.T.; Kogel, Albert J. van der

    2002-01-01

    Purpose: To estimate dose-volume effects in the rat cervical spinal cord with protons. Methods and Materials: Wistar rats were irradiated on the cervical spinal cord with a single fraction of unmodulated protons (150-190 MeV) using the shoot through method, which employs the plateau of the depth-dose profile rather than the Bragg peak. Four different lengths of the spinal cord (2, 4, 8, and 20 mm) were irradiated with variable doses. The endpoint for estimating dose-volume effects was paralysis of fore or hind limbs. Results: The results obtained with a high-precision proton beam showed a marginal increase of ED 50 when decreasing the irradiated cord length from 20 mm (ED 50 = 20.4 Gy) to 8 mm (ED 50 = 24.9 Gy), but a steep increase in ED 50 when further decreasing the length to 4 mm (ED 50 = 53.7 Gy) and 2 mm (ED 50 = 87.8 Gy). These results generally confirm data obtained previously in a limited series with 4-6-MV photons, and for the first time it was possible to construct complete dose-response curves down to lengths of 2 mm. At higher ED 50 values and shorter lengths irradiated, the latent period to paralysis decreased from 125 to 60 days. Conclusions: Irradiation of variable lengths of rat cervical spinal cord with protons showed steeply increasing ED 50 values for lengths of less than 8 mm. These results suggest the presence of a critical migration distance of 2-3 mm for cells involved in regeneration processes

  18. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W [Sunnybrook Health Sciences Center, Odette Cancer Centre, Toronto, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada); Safigholi, H; Soliman, A [Sunnybrook Research Institute, Toronto, ON (Canada)

    2016-06-15

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  19. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    International Nuclear Information System (INIS)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W; Safigholi, H; Soliman, A

    2016-01-01

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  20. Study of the boron levels in serum after implantation of different ratios nano-hexagonal boron nitride-hydroxy apatite in rat femurs.

    Science.gov (United States)

    Atila, Alptug; Halici, Zekai; Cadirci, Elif; Karakus, Emre; Palabiyik, Saziye Sezin; Ay, Nuran; Bakan, Feray; Yilmaz, Sahin

    2016-01-01

    Boron and its derivatives are effective in bone recovery and osteointegration. However, increasing the boron levels in body liquids may cause toxicity. The aim of our study is to investigate serum boron levels using ICP-MS after implantation of different ratios of nano-hBN-HA composites in rat femurs. All rats were (n=126) divided into five experimental groups (n=24) and one healthy group (6 rats); healthy (Group1), femoral defect + %100 HA (Group2), femoral defect + %2.5 hBN + %97.5 HA (Group3), femoral defect + %5 hBN + %95 HA (Group4), femoral defect + %10 hBN + %90 HA (Group5), femoral defect + %100 hBN (Group6). The femoral defect was created in the distal femur (3mm drill-bit). Each implant group was divided into four different groups (n=24) also 6 rats sacrificed for each groups in one week intervals during four weeks. In our results; at 1, 2, 3, and 4 weeks after implantation near bone tissue, serum levels of boron were evaluated using ICP-MS. We demonstrated that neither short-term nor long-term implantation of hBN-HA composite resulted in statistically increased serum boron levels in experimental groups compared to healthy group. In conclusion, this study investigated the implant material produced form hBN-HA for the first time. Our data suggest that hBN is a new promising target for biomaterial and implant bioengineers. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Brain activation in response to visceral stimulation in rats with amygdala implants of corticosterone: an FMRI study.

    Directory of Open Access Journals (Sweden)

    Anthony C Johnson

    2010-01-01

    Full Text Available Although visceral pain of gastrointestinal (GI origin is the major complaint in patients with irritable bowel syndrome (IBS it remains poorly understood. Brain imaging studies suggest a defect in brain-gut communication in IBS with a greater activation of central arousal circuits including the amygdala. Previously, we found that stereotaxic implantation of corticosterone (CORT onto the amygdala in rats induced anxiety and colonic hypersensitivity. In the present study we used functional magnetic resonance imaging (fMRI to identify specific brain sites activated in a rat model characterized by anxiety and colonic hypersensitivity.Anesthetized male rats received micropellets (30 microg each of either CORT or cholesterol (CHOL, to serve as a control, implanted stereotaxically on the dorsal margin of each amygdala. Seven days later, rats were anesthetized and placed in the fMRI magnet (7T. A series of isobaric colorectal balloon distensions (CRD - 90s 'off', 30s 'on', 8 replicates at two pressures (40 and 60 mmHg were performed in a standard block-design. Cross correlation statistical analysis was used to determine significant differences between distended and non-distended states in CORT and CHOL-treated animals. Analysis of the imaging data demonstrated greater overall brain activation in response to CRD in rats with CORT implants compared to CHOL controls. Additionally, CORT implants produced significant positive bilateral increases in MRI signal in response to CRD in specific nuclei known as integration sites important in anxiety and pain perception.These data indicate that chronic exposure of the amygdala to elevated levels of CORT enhances overall brain activation in response to CRD, and identified other specific brain regions activated in response to mechanical distension of the colon. These results demonstrate the feasibility of performing fMRI imaging in a rodent model that supports clinical observations in IBS patients with enhanced

  2. Tribological studies of ion-implanted steel constituents

    International Nuclear Information System (INIS)

    Wei, Ronghau.

    1990-01-01

    Tribological properties of ion-implanted ferrite and austenite were studied systematically using a unique oscillating pin-on-disc wear tester. Results show that nitrogen implantation at elevated temperatures to high doses dramatically improves the adhesive wear resistance of ferrite and the critical load at which the adhesive wear mechanism changes from mild to severe for austenite. The wear resistance of nitrogen-implanted ferrite is determined by the nitride formed. Extremely hard solid solutions of nitrogen develop on the implanted austenite surfaces and induce three orders of magnitude reductions in wear rates. The implantation conditions that should be used to produce deep, wear-resistant layers for both steels are discussed in detail. Oscillating pin-on-disc wear tests demonstrate that nitrogen does not diffuse during the wearing process although tests conducted using conventional fixed pin-on-disc test equipment could erroneously suggest this occurs. Taken together, the results show that high-dose-rate implantation at low energies yields very-high-quality implanted surfaces at low cost

  3. Dose-ranging pharmacokinetics of colistin methanesulphonate (CMS) and colistin in rats following single intravenous CMS doses.

    Science.gov (United States)

    Marchand, Sandrine; Lamarche, Isabelle; Gobin, Patrice; Couet, William

    2010-08-01

    The aim of this study was to evaluate the effect of colistin methanesulphonate (CMS) dose on CMS and colistin pharmacokinetics in rats. Three rats per group received an intravenous bolus of CMS at a dose of 5, 15, 30, 60 or 120 mg/kg. Arterial blood samples were drawn at 0, 5, 15, 30, 60, 90, 120, 150 and 180 min. CMS and colistin plasma concentrations were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pharmacokinetic parameters of CMS and colistin were calculated by non-compartmental analysis. Linear relationships were observed between CMS and colistin AUCs to infinity and CMS doses, as well as between CMS and colistin C(max) and CMS doses. CMS and colistin pharmacokinetics were linear for a range of colistin concentrations covering the range of values encountered and recommended in patients even during treatment with higher doses.

  4. Xenotransplantation of uterine leiomyoma in Wistar rats: a pilot study.

    Science.gov (United States)

    Sousa, Willane Bandeira de; Garcia, João Batista Santos; Nogueira Neto, João; Furtado, Pablo Gustavo Ribeiro; Anjos, Jonhnathan Adriano Araújo dos

    2015-07-01

    To evaluate whether xenografts derived from hysterectomized patients would implant successfully and lead to uterine leiomyoma in Wistar rats. This experimental study examined six female Wistar rats implanted with uterine leiomyoma obtained from patients who underwent hysterectomies at the gynecological surgery service of the HUUFMA. The rats were divided into two groups. Group I consisted of three rats in which the uterine leiomyoma had been implanted in the parietal peritoneum, and group II consisted of three rats in which the uterine leiomyoma was implanted in the subcutaneous tissue. The immunosuppressant mycophenolate mofetil (MMF) was administered orally by gavage (at a dose of 40 mg/kg of body weight) to prevent transplant rejection starting 15 days before the transplant and continuing throughout the entire experiment. After four weeks, necrosis and neovascularization were evaluated histologically in both groups and were classified as either absent or present. Lymphocytic inflammatory infiltration was also examined and classified as mild, moderate or intense (by hematoxylin and eosin staining), and fibrosis was classified as grade I-III (by Masson's trichrome staining). Necrosis was absent from all three rats in group I and was observed in only one rat from group II. Neovascularization was present in two rats from group I and in only one rat from group II. The lymphocytic inflammatory infiltrate was mild in two rats and moderate in one rat from group I, and it was moderate in two rats and intense in one rat from group II. Two rats from group 1 exhibited grade III fibrosis, and one rat presented grade I fibrosis. In group II, two rats presented grade I fibrosis and one rat had grade II fibrosis. When necrosis and neovascularization were evaluated as variables, group I demonstrated greater evidence of successful implantation when compared to group II, indicating that the peritoneal implantation technique produces better results than the subcutaneous approach (p

  5. Dosing-time-dependent variation in biliary excretion of flomoxef in rats.

    Science.gov (United States)

    Hishikawa, Shuji; Sugimoto, Koh-ichi; Kobayashi, Eiji; Kumagai, Yuji; Fujimura, Akio

    2003-05-01

    We previously reported that the biliary excretion of flomoxef, an oxacephem antibiotic, was greater after dosing at 21:00 than at 09:00 h in diurnally active human subjects. The present study was undertaken to examine whether the biliary excretion of flomoxef is also dependent on its dosing time in rats. Adult male Wistar rats were housed under light on at 07:00 h and off at 19:00 h. Bile fluid was completely drained through a polyethylene catheter from conscious animals. Flomoxef (20 mg/kg) was injected into the tail vein at 09:00 or 21:00 h by a cross-over design, and drained bile fluid was collected for 8 h after each dosing. The maximum concentration of biliary flomoxef was significantly greater and its total excretion tended to be greater after dosing at 09:00 than 21:00 h. These results suggest the biliary excretion of flomoxef is enhanced after dosing at the beginning of the rest period in rats, as it is in humans.

  6. Enzymatic activity of granulations tissues under low doses of radiation. Biochemical analysis in rats

    International Nuclear Information System (INIS)

    Tosoni, Guilherme Monteiro; Boscolo, Frab Norberto; Cury, Jaime Aparecido; Watanabe, Plauto Christopher Aranha

    1994-01-01

    This paper was designed to investigate in the rat subcutaneous sponge-induced granulation tissue under low doses of X-ray, the activity of alkaline phosphatase, 5'nucleotide phosphodiesterase and adenosine triphosphatase (ATPase) enzymes. One hundred and fourteen Wistar rats were divided into three groups, as follows: Group I as control, Group II that received single 7,14 R in split-dosis immediately after sponge-implantation at the third and fifth days postoperatively. Biopsies were taken after 7, 11, 14, 21 and 28 days and the activity of the three enzymes was determined. The results have shown that in Group II alkaline phosphatase had higher activity in the 14th day of tissue evolution when compared to Groups I and III . The 5'nucleotide phosphodiesterase activity in Group I was similar in all days checked, although in Group II the enzyme showed higher activity in 7th day and lower in 21st. In Group III the activity was higher after 14 and 7 days and lower after 28 and 21 days. There was no observation of changing in adenosine triphosphatase (ATPase) activity when the three groups were compared. (author)

  7. Morfologia e função fagocitária de implante esplênico autógeno regenerado em ratos Morphology and phagocytic function of regenerated autogenous splenic implant in rats

    Directory of Open Access Journals (Sweden)

    Ruy Garcia Marques

    2004-12-01

    Full Text Available Objetivo: O objetivo deste trabalho é analisar a regeneração morfológica de tecido esplênico auto-implantado em ratos Wistar, verificando a função fagocitária bacteriana de seus macrófagos. Métodos: Utilizou-se um modelo experimental com ratos jovens e adultos, de ambos os sexos, submetidos a esplenectomia total combinada com auto-implante de fatias de toda a massa esplênica no omento maior. Dezesseis semanas após, os animais foram inoculados por via intravenosa com suspensão de Escherichia coli AB1157 e, após 20 minutos, foram mortos por dose letal de halotano, sendo submetidos a laparotomia para retirada dos auto-implantes esplênicos. A análise estatística foi realizada com o teste t de Student, com ênfase na comparação da massa de auto-implante esplênico regenerada entre animais jovens e adultos de ambos os sexos. Resultados: Ocorreu regeneração do auto-implante esplênico em todos os animais. Machos jovens e fêmeas adultas apresentaram maior percentual de regeneração. Observou-se aspecto morfológico microscópico semelhante em todos os animais. O tecido esplênico regenerado mostrou as polpas vermelha e branca, com desarranjo arquitetural moderado, bem como folículos linfóides. Os vasos sangüíneos mostravam paredes preservadas, sem sinais de vasculite ou trombose. Foram encontrados macrófagos contendo grumos de bactérias, bem como macrófagos contendo pigmento de hemossiderina intracitoplasmáticos. Conclusão: O auto-implante esplênico, no omento maior, em ratos, adquire a arquitetura macro e microscópica de um baço normal, de dimensão menor e preserva a função fagocitária bacteriana.Purpose: To analyze the morphologic regeneration of autotransplanted splenic tissue in Wistar rats and to determine the bacterial phagocytic function of their macrophages. Methods: We utilized an experimental model including young and adult rats, of both sexes, submitted to total splenectomy combined with

  8. Insulin-like growth factor binding protein-3 affects osteogenic efficacy on dental implants in rat mandible

    Energy Technology Data Exchange (ETDEWEB)

    Bhattarai, Govinda; Lee, Young-Hee [Department of Oral Biochemistry, Institute of Oral Bioscience, School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of); Lee, Min-Ho [Department of Dental Materials, Institute of Oral Bioscience, School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of); Park, Il-Song [Division of Advanced Materials Engineering, Research Center for Advanced Materials, Development and Institute of Biodegradable Materials, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Yi, Ho-Keun, E-mail: yihokn@chonbuk.ac.kr [Department of Oral Biochemistry, Institute of Oral Bioscience, School of Dentistry, Chonbuk National University, Jeonju (Korea, Republic of)

    2015-10-01

    Insulin like growth factor binding protein-3 (IGFBP-3) in bone cells and its utilization in dental implants have not been well studied. The aim of this study was to determine the osteogenic efficacy of chitosan gold nanoparticles (Ch-GNPs) conjugated with IGFBP-3 coated titanium (Ti) implants. Ch-GNPs were conjugated with IGFBP-3 plasmid DNA through a coacervation process. Conjugation was cast over Ti surfaces, and cells were seeded on coated surfaces. For in vitro analysis the expression of different proteins was analyzed by immunoblotting. For in vivo analysis, Ch-GNP/IGFBP-3 coated implants were installed in rat mandibles. Four weeks post-implantation, mandibles were examined by microcomputed tomography (μCT), immunohistochemistry, hematoxylin & eosin and tartrate resistance acid phosphatase staining. In vitro overexpressed Ch-GNP/IGFBP-3 coated Ti surfaces was associated with activation of extracellular signal related kinase (ERK), inhibition of the stress activated protein c-Jun N-terminal kinase (JNK) and enhanced bone morphogenetic protein (BMP)-2 and 7 compared to control. Further, in vivo, Ch-GNP/IGFBP-3 coated implants were associated with inhibition of implant induced osteoclastogenesis molecules, receptor activator of nuclear factor kappa-B ligand (RANKL) and enhanced expression of osteogenic molecules including BMP2/7 and osteopontin (OPN). The μCT analysis demonstrated that IGFBP-3 increased the volume of newly formed bone surrounding the implants compared to control (n = 5; p < 0.05). These results support the view that IGFBP-3 overexpression diminishes osteoclastogenesis and enhances osteogenesis of Ti implants, and can serve as a potent molecule for the development of good implantation. - Highlights: • Chitosan gold nanoparticles were conjugated with IGFBP-3 and coated onto surface of the titanium implants for gene delivery to bone. • Implants were inserted in rat mandible for 4 weeks. • Parameters studied: histopathology and radiology.

  9. Insulin-like growth factor binding protein-3 affects osteogenic efficacy on dental implants in rat mandible

    International Nuclear Information System (INIS)

    Bhattarai, Govinda; Lee, Young-Hee; Lee, Min-Ho; Park, Il-Song; Yi, Ho-Keun

    2015-01-01

    Insulin like growth factor binding protein-3 (IGFBP-3) in bone cells and its utilization in dental implants have not been well studied. The aim of this study was to determine the osteogenic efficacy of chitosan gold nanoparticles (Ch-GNPs) conjugated with IGFBP-3 coated titanium (Ti) implants. Ch-GNPs were conjugated with IGFBP-3 plasmid DNA through a coacervation process. Conjugation was cast over Ti surfaces, and cells were seeded on coated surfaces. For in vitro analysis the expression of different proteins was analyzed by immunoblotting. For in vivo analysis, Ch-GNP/IGFBP-3 coated implants were installed in rat mandibles. Four weeks post-implantation, mandibles were examined by microcomputed tomography (μCT), immunohistochemistry, hematoxylin & eosin and tartrate resistance acid phosphatase staining. In vitro overexpressed Ch-GNP/IGFBP-3 coated Ti surfaces was associated with activation of extracellular signal related kinase (ERK), inhibition of the stress activated protein c-Jun N-terminal kinase (JNK) and enhanced bone morphogenetic protein (BMP)-2 and 7 compared to control. Further, in vivo, Ch-GNP/IGFBP-3 coated implants were associated with inhibition of implant induced osteoclastogenesis molecules, receptor activator of nuclear factor kappa-B ligand (RANKL) and enhanced expression of osteogenic molecules including BMP2/7 and osteopontin (OPN). The μCT analysis demonstrated that IGFBP-3 increased the volume of newly formed bone surrounding the implants compared to control (n = 5; p < 0.05). These results support the view that IGFBP-3 overexpression diminishes osteoclastogenesis and enhances osteogenesis of Ti implants, and can serve as a potent molecule for the development of good implantation. - Highlights: • Chitosan gold nanoparticles were conjugated with IGFBP-3 and coated onto surface of the titanium implants for gene delivery to bone. • Implants were inserted in rat mandible for 4 weeks. • Parameters studied: histopathology and radiology.

  10. Technical Evaluation of Radiation Dose Delivered in Prostate Cancer Patients as Measured by an Implantable MOSFET Dosimeter

    International Nuclear Information System (INIS)

    Beyer, Gloria P.; Scarantino, Charles W.; Prestidge, Bradley R.; Sadeghi, Amir G.; Anscher, Mitchell S.; Miften, Moyed; Carrea, Tammy B.; Sims, Marianne C.; Black, Robert D.

    2007-01-01

    Purpose: To perform a comparison of the daily measured dose at depth in tissue with the predicted dose values from treatment plans for 29 prostate cancer patients involved in a clinical trial. Methods and Materials: Patients from three clinical sites were implanted with one or two dosimeters in or near the prostatic capsule. The implantable device, known as the DVS, is based on a metal-oxide-semiconductor field effect transistor (MOSFET) detector. A portable telemetric readout system couples to the dosimeter antenna (visible on kilovoltage, computed tomography, and ultrasonography) for data transfer. The predicted dose values were determined by the location of the MOSFET on the treatment planning computed tomography scan. Serial computed tomography images were taken every 2 weeks to evaluate any migration of the device. The clinical protocol did not permit alteration of the treatment parameters using the dosimeter readings. For some patients, one of several image-guided radiotherapy (RT) modalities was used for target localization. Results: The evaluation of dose discrepancy showed that in many patients the standard deviation exceeded the previous values obtained for the dosimeter in a phantom. In some patients, the cumulative dose disagreed with the planned dose by ≥5%. The data presented suggest that an implantable dosimeter can help identify dose discrepancies (random or systematic) for patients treated with external beam RT and could be used as a daily treatment verification tool for image-guided RT and adaptive RT. Conclusion: The results of our study have shown that knowledge of the dose delivered per fraction can potentially prevent over- or under-dosage to the treatment area and increase the accuracy of RT. The implantable dosimeter could also be used as a localizer for image-guided RT

  11. Dose response of rat retinal microvessels to proton dose schedules used clinically: a pilot study

    International Nuclear Information System (INIS)

    Archambeau, John O.; Mao, Xiao W.; McMillan, Paul J.; Gouloumet, Vanessa L.; Oeinck, Steven C.; Grove, Roger; Yonemoto, Leslie T.; Slater, Jerry D.; Slater, James M.

    2000-01-01

    Purpose: This preclinical rat pilot study quantifies retinal microvessel, endothelial, and pericyte population changes produced by proton irradiation Methods and Materials: The left eyes of rats were irradiated with single doses of 8, 14, 20, and 28 Gy protons; right eyes, with two fractions. Animals were euthanized, and eyes were removed; elastase digests were prepared, and cell populations were counted in sample fields. Results were compared with unirradiated controls. Results: Progressive time- and dose-dependent endothelial cell loss occurred following all schedules. Cell loss was significantly different from control values (p 0 phase of the mitotic cycle. 28 Gy produced photoreceptor cell loss. Conclusion: The retinal digest is an elegant bioassay to quantify the microvessel population response. Single- and split-dose schedules appear to yield similar outcomes, in terms of endothelial cell density

  12. Microscopic dose distribution around PuO2 particles in lungs of hamsters, rats and dogs

    International Nuclear Information System (INIS)

    Diel, J.H.; Mewhinney, J.A.; Guilmette, R.A.

    1982-01-01

    Syrian hamsters, Fischer-344 rats and Beagle dogs inhaled monodisperse aerosols of PuO 2 and were sacrificed 1 to 16 days after exposure. The microscopic distribution of dose and tissue-at-risk around individual particles in lung was studied using autoradiographs of the lungs. The dose pattern in dogs and rats was more diffuse than in hamsters, resulting in a calculation of about twice the tumor incidence in rats and dogs as in hamsters on the basis of dose pattern using the same dose-effect model for all three species. The tumorigenic effect of inhaled insoluble PuO 2 particles depends on the species inhaling the material; Syrian hamsters are much less susceptible than are rats or dogs. It has been suggested that a difference in dose distribution resulting from differences in particle distributions in the two species may contribute to the differences in susceptibility in Syrian hamsters and rats. The role of dose distribution in lung cancer production is explored in this study by measuring microscopic dose patterns in regions surrounding single PuO 2 particles in lung. The alveolar structures of the dog and rat are different than those of the hamster. Based on these measurements, particles of PuO 2 in lung are more likely to cause lung cancer in dogs and rats than in hamsters

  13. SU-E-T-492: The Dosimetric and Clinical Impact of the Metallic Dental Implants on Radiation Dose Distributions in IMRT Head and Neck Cancer Patients.

    Science.gov (United States)

    Wang, L; Xing, L; Le, Q

    2012-06-01

    In H&N cancer patients, the development of oral mucositis is related closely to the radiation dose to the oral cavity. It is generally presumed that the existence of metallic dental implants makes it worse due to the scattering effect of the metal. This study investigates the effects of the dental implants on radiation doses to PTV, tongue mucosa, and other structures for IMRT H&N cancer patients by Monte Carlo (MC) dose calculations. Two H&N cancer patients who have dental implant and are treated by IMRT technique are selected for the purpose. The BEAMnrc/DOSXYZnrc MC codes are employed for the CT-image based dose calculations. The radiation sources are the validated Varian phase-space files for 6MV linac beams. The CT image artifacts caused by the dental fillings are replaced by tissue material. Two sets of MC calculations for each patient are performed at a calculation statistics of 1%: one treats all dental implants as bones, the other substitutes the implants by metal of either titanium or gold with correct density. Doses in PTV and various tissue structures are compared for the two scenarios. With titanium implant, there is no significant difference in doses to PTV and tongue mucosa from that when treating implant as bone. With gold implant, the mean dose to PTV is slightly lowered by 1%; the mean dose to tongue mucosa is reduced by less than 0.5%, although the maximum dose is increased by 5%. The scattering dose from titanium implants is not of concern for H&N patients irradiated by 6MV IMRT beams. For gold implants, the scattering dose to tongue mucosa is not as severe as presumed; and the dose to PTV could be slightly compromised due to the attenuation effect of the metal. This work was supported in part by Varian Medical Systems. © 2012 American Association of Physicists in Medicine.

  14. High-dose dextromethorphan produces myelinoid bodies in the hippocampus of rats

    Directory of Open Access Journals (Sweden)

    Hai-Quyen Tran

    2016-10-01

    Full Text Available Dextromethorphan (DM administered at supra-antitussive doses produce psychotoxic and neurotoxic effects in humans. We administered DM (80 mg/kg to rats intraperitoneally to determine the ultrastructural change induced by DM, because intraperitoneal route is sensitive for the behavioral responses. Treatment with DM resulted in mitochondrial dysfunction and formation of myelinoid bodies in the hippocampus. MK-801 [(+-5-methyl-10,11-dihydro-5H-dibenzo[a,d]cyclohepten-5,10-imine maleate] attenuated DM-induced cytosolic oxidative burdens. However, neither MK-801 nor naloxone affected DM-induced mitochondrial dysfunction and formation of myelinoid bodies, indicating that the neurotoxic mechanism needs to be further elucidated. Therefore, the spectrum of toxicological effects associated with DM need to be reassessed.

  15. In vivo genotoxicity of furan in F344 rats at cancer bioassay doses

    International Nuclear Information System (INIS)

    Ding, Wei; Petibone, Dayton M.; Latendresse, John R.; Pearce, Mason G.; Muskhelishvili, Levan; White, Gene A.; Chang, Ching-Wei; Mittelstaedt, Roberta A.; Shaddock, Joseph G.; McDaniel, Lea P.; Doerge, Daniel R.; Morris, Suzanne M.; Bishop, Michelle E.; Manjanatha, Mugimane G.; Aidoo, Anane; Heflich, Robert H.

    2012-01-01

    Furan, a potent rodent liver carcinogen, is found in many cooked food items and thus represents a human cancer risk. Mechanisms for furan carcinogenicity were investigated in male F344 rats using the in vivo Comet and micronucleus assays, combined with analysis of histopathological and gene expression changes. In addition, formamidopyrimidine DNA glycosylase (Fpg) and endonuclease III (EndoIII)-sensitive DNA damage was monitored as a measure of oxidative DNA damage. Rats were treated by gavage on four consecutive days with 2, 4, and 8 mg/kg bw furan, doses that were tumorigenic in 2-year cancer bioassays, and with two higher doses, 12 and 16 mg/kg. Rats were killed 3 h after the last dose, a time established as producing maximum levels of DNA damage in livers of furan-treated rats. Liver Comet assays indicated that both DNA strand breaks and oxidized purines and pyrimidines increased in a near-linear dose-responsive fashion, with statistically significant increases detected at cancer bioassay doses. No DNA damage was detected in bone marrow, a non-target tissue for cancer, and peripheral blood micronucleus assays were negative. Histopathological evaluation of liver from furan-exposed animals produced evidence of inflammation, single-cell necrosis, apoptosis, and cell proliferation. In addition, genes related to apoptosis, cell-cycle checkpoints, and DNA-repair were expressed at a slightly lower level in the furan-treated livers. Although a mixed mode of action involving direct DNA binding cannot be ruled out, the data suggest that furan induces cancer in rat livers mainly through a secondary genotoxic mechanism involving oxidative stress, accompanied by inflammation, cell proliferation, and toxicity. -- Highlights: ► Furan is a potent rodent liver carcinogen and represents a human cancer risk. ► Furan induces DNA damage in rat liver at cancer bioassay doses. ► Furan induces oxidative stress, inflammation and cell proliferation in rat liver. ► Expression of

  16. Clinical doses of citalopram or reboxetine differentially modulate passive and active behaviors of female Wistar rats with high or low immobility time in the forced swimming test.

    Science.gov (United States)

    Flores-Serrano, Ana Gisela; Vila-Luna, María Leonor; Álvarez-Cervera, Fernando José; Heredia-López, Francisco José; Góngora-Alfaro, José Luis; Pineda, Juan Carlos

    2013-09-01

    The sensitivity of immobility time (IT) to antidepressant-drugs differs in rats expressing high or low motor activity during the forced swimming test (FST). However, whether this heterogeneity is expressed after the administration of the most selective serotonin and norepinephrine reuptake inhibitors (SSRIs and SNRIs, respectively) is unknown. We compared the influence of either the SSRI citalopram or the SNRI reboxetine with the tricyclic antidepressant amitriptyline on two subgroups of female Wistar rats expressing high IT (HI; at or above the mean value) or low IT (LI; below the mean) during the initial 5 min of the first session of the FST. None of the tested drugs increased motor activity in the open field test. When vehicle was applied to either HI or LI rats, IT increased in the second session of the FST. This increment concurred with a simultaneous climbing time (CT) decrement. When amitriptyline (15 mg/kg) was tested the CT increased for both HI and LI rats. This increment was accompanied by an IT decrement in HI and LI rats. Reboxetine (0.16 or 1 mg/kg) precluded IT and CT changes in both HI and LI rats and produced a swimming time reduction. Citalopram (0.4, 1, and 3 mg/kg) essentially mimicked the influence of reboxetine on the IT and CT in LI rats, as well as in HI rats, but in the latter case only at 3 mg/kg. Yet, at the dose of 10 mg/kg citalopram lacked this effect in both subgroups. No differences were detected when the IT of LI rats was evaluated with citalopram (3 mg/kg) during estrus or diestrus stage. These results show that clinical doses of citalopram produced an antidepressant-like effect selectively in LI rats, while amitriptyline or reboxetine produced this effect in both LI and HI animals. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

    International Nuclear Information System (INIS)

    Monajemi, T. T.; Clements, Charles M.; Sloboda, Ron S.

    2011-01-01

    Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of 125 I, 103 Pd, and 137 Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, Δ, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE preplan , in a 5x5x5 cm 3 volume for 125 I (Oncura 6711), 103 Pd (Theragenics 200), and 131 Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes (Δ=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE preplan for our edema model

  18. Opposite effects of low and high doses of Abeta42 on electrical network and neuronal excitability in the rat prefrontal cortex.

    Science.gov (United States)

    Wang, Yun; Zhang, Guangping; Zhou, Hongwei; Barakat, Amey; Querfurth, Henry

    2009-12-21

    Changes in neuronal synchronization have been found in patients and animal models of Alzheimer's disease (AD). Synchronized behaviors within neuronal networks are important to such complex cognitive processes as working memory. The mechanisms behind these changes are not understood but may involve the action of soluble beta-amyloid (Abeta) on electrical networks. In order to determine if Abeta can induce changes in neuronal synchronization, the activities of pyramidal neurons were recorded in rat prefrontal cortical (PFC) slices under calcium-free conditions using multi-neuron patch clamp technique. Electrical network activities and synchronization among neurons were significantly inhibited by low dose Abeta42 (1 nM) and initially by high dose Abeta42 (500 nM). However, prolonged application of high dose Abeta42 resulted in network activation and tonic firing. Underlying these observations, we discovered that prolonged application of low and high doses of Abeta42 induced opposite changes in action potential (AP)-threshold and after-hyperpolarization (AHP) of neurons. Accordingly, low dose Abeta42 significantly increased the AP-threshold and deepened the AHP, making neurons less excitable. In contrast, high dose Abeta42 significantly reduced the AP-threshold and shallowed the AHP, making neurons more excitable. These results support a model that low dose Abeta42 released into the interstitium has a physiologic feedback role to dampen electrical network activity by reducing neuronal excitability. Higher concentrations of Abeta42 over time promote supra-synchronization between individual neurons by increasing their excitability. The latter may disrupt frontal-based cognitive processing and in some cases lead to epileptiform discharges.

  19. Opposite effects of low and high doses of Abeta42 on electrical network and neuronal excitability in the rat prefrontal cortex.

    Directory of Open Access Journals (Sweden)

    Yun Wang

    Full Text Available Changes in neuronal synchronization have been found in patients and animal models of Alzheimer's disease (AD. Synchronized behaviors within neuronal networks are important to such complex cognitive processes as working memory. The mechanisms behind these changes are not understood but may involve the action of soluble beta-amyloid (Abeta on electrical networks. In order to determine if Abeta can induce changes in neuronal synchronization, the activities of pyramidal neurons were recorded in rat prefrontal cortical (PFC slices under calcium-free conditions using multi-neuron patch clamp technique. Electrical network activities and synchronization among neurons were significantly inhibited by low dose Abeta42 (1 nM and initially by high dose Abeta42 (500 nM. However, prolonged application of high dose Abeta42 resulted in network activation and tonic firing. Underlying these observations, we discovered that prolonged application of low and high doses of Abeta42 induced opposite changes in action potential (AP-threshold and after-hyperpolarization (AHP of neurons. Accordingly, low dose Abeta42 significantly increased the AP-threshold and deepened the AHP, making neurons less excitable. In contrast, high dose Abeta42 significantly reduced the AP-threshold and shallowed the AHP, making neurons more excitable. These results support a model that low dose Abeta42 released into the interstitium has a physiologic feedback role to dampen electrical network activity by reducing neuronal excitability. Higher concentrations of Abeta42 over time promote supra-synchronization between individual neurons by increasing their excitability. The latter may disrupt frontal-based cognitive processing and in some cases lead to epileptiform discharges.

  20. Importance of beta-blocker dose in prevention of ventricular tachyarrhythmias, heart failure hospitalizations, and death in primary prevention implantable cardioverter-defibrillator recipients

    DEFF Research Database (Denmark)

    Ruwald, A C; Gislason, G H; Vinther, M

    2018-01-01

    Aims: There is a paucity of studies investigating a dose-dependent association between beta-blocker therapy and risk of outcome. In a nationwide cohort of primary prevention implantable cardioverter-defibrillator (ICD) patients, we aimed to investigate the dose-dependent association between beta-blocker...... therapy and risk of ventricular tachyarrhythmias (VT/VF), heart failure (HF) hospitalizations, and death. Methods and results: Information on ICD implantation, endpoints, comorbidities, beta-blocker usage, type, and dose were obtained through Danish nationwide registers. The two major beta-blockers...... carvedilol and metoprolol were examined in three dose levels; low (metoprolol ≤ 25 mg; carvedilol ≤ 12.5 mg), intermediate (metoprolol 26-199 mg; carvedilol 12.6-49.9 mg), and high (metoprolol ≥ 200 mg; carvedilol ≥ 50 mg). Time to events was investigated utilizing multivariate Cox models with beta-blocker...

  1. Dose and time dependent ototoxicity of aspartame in rats.

    Science.gov (United States)

    Ozturan, Orhan; Dogan, Remzi; Tugrul, Selahattin; Gedik, Ozge; Sjostrand, Alev Pektas; Yildirim, Yavuz Selim

    2017-04-01

    Low-dose administration of Aspartame (Ap) did not produce a significant ototoxic effect at the end of the 6th month. However, duration of the ototoxic effect is shortened and severity of the effect is increased as dose and duration of Ap administration is increased. While Ap toxicity has been studied in short- and long-term studies, its effects on hearing have not been investigated. This study was conducted to evaluate the effects of long-term consumption of Ap administered in various doses on hearing status of rats. The study included 54 female Wistar Albino rats. Ap was given for 6 months to the rats. The groups were assigned according to levels of Ap dosage. DPOAE and ABR tests were utilized for serial hearing evaluations. Serial hearing measurement times were designed as baseline, 1st week, 2nd week, 1st, 2nd, 3rd, and 6th months. While audiological parameters deteriorated with 100 mg/kg/day dose after the 3rd month, ABR thresholds were elevated and DPOAE values were significantly decreased in 500 mg/kg/day and 1000 mg/kg/day applications after the 2nd month. In 2000 mg/kg/day and 4000 mg/kg/day applications, deteriorations in audiological parameters were detected as early as the first and second months; respectively.

  2. Effect of geometrical optimization on the treatment volumes and the dose homogeneity of biplane interstitial brachytherapy implants

    International Nuclear Information System (INIS)

    Anacak, Yavuz; Esassolak, Mustafa; Aydin, Ayhan; Aras, Arif; Olacak, Ibrahim; Haydaroglu, Ayfer

    1997-01-01

    Background and purpose: The isodose distributions of HDR stepping source brachytherapy implants can be modified by changing dwell times and this procedure is called optimization. The purpose of this study is to evaluate the effect of geometrical optimization on the brachytherapy volumes and the dose homogeneity inside the implant and to compare them with non-optimized counterparts. Material and methods: A set of biplane breast implants consisting of 84 different configurations have been digitized by the planning computer and volumetric analysis was performed for both non-optimized and geometrically optimized implants. Treated length (T L ), treated volume (V 100 ), irradiated volume (V 50 ), overdose volume (V 200 ) and quality index (QI) have been calculated for every non-optimized implant and compared to its corresponding geometrically optimized implant having a similar configuration and covering the same target length. Results: The mean T L was 74.48% of the active length (A L ) for non-optimized implants and was 91.87% for optimized implants (P 50 /V 100 value was 2.71 for non-optimized implants and 2.65 for optimized implants (P 200 /V 100 value was 0.09 for non-optimized implants and 0.10 for optimized implants (P < 0.001). Conclusions: By performing geometrical optimization it is possible to implant shorter needles for a given tumour to adequately cover the target volume with the reference isodose and thus surgical damage is reduced. The amount of healthy tissues outside the target receiving considerable radiation is significantly reduced due to the decrease in irradiated volume. Dose homogeneity inside the implant is significantly improved. Although there is a slight increase of overdose volume inside the implant, this increase is considered to be negligible in clinical applications

  3. Hall effect mobility for SiC MOSFETs with increasing dose of nitrogen implantation into channel region

    Science.gov (United States)

    Noguchi, Munetaka; Iwamatsu, Toshiaki; Amishiro, Hiroyuki; Watanabe, Hiroshi; Kita, Koji; Yamakawa, Satoshi

    2018-04-01

    The Hall effect mobility (μHall) of the Si-face 4H-SiC metal–oxide–semiconductor field effect transistor (MOSFET) with a nitrogen (N)-implanted channel region was investigated by increasing the N dose. The μHall in the channel region was systematically examined regarding channel structures, that is, the surface and buried channels. It was experimentally demonstrated that increasing the N dose results in an improvement in μHall in the channel region due to the formation of the buried channel. However, further increase in N dose was found to decrease the μHall in the channel region, owing to the decrease in the electron mobility in the N-implanted bulk region.

  4. Alterations in water and electrolyte absorption in the rat colon following neutron irradiation: influence of neutron component and irradiation dose.

    Science.gov (United States)

    Dublineau, I; Ksas, B; Joubert, C; Aigueperse, J; Gourmelon, P; Griffiths, N M

    2002-12-01

    To study the absorptive function of rat colon following whole-body exposure to neutron irradiation, either to the same total dose with varying proportion of neutrons or to the same neutron proportion with an increasing irradiation dose. Different proportions of neutron irradiation were produced from the reactor SILENE using a fissile solution of uranium nitrate (8, 47 and 87% neutron). Water and electrolyte fluxes were measured in the rat in vivo under anaesthesia by insertion into the descending colon of an agarose gel cylinder simulating the faeces. Functional studies were completed by histological analyses. In the first set of experiments, rats received 3.8 Gy with various neutron percentages and were studied from 1 to 14 days after exposure. In the second set of experiments, rats were exposed to increasing doses of irradiation (1-4Gy) with a high neutron percentage (87%n) and were studied at 4 days after exposure. The absorptive capacity of rat colon was diminished by irradiation at 3-5 days, with a nadir at 4 days. The results demonstrate that an increase in the neutron proportion is associated with an amplification of the effects. Furthermore, a delay in the re-establishment of normal absorption was observed with the high neutron proportion (87%n). A dose-dependent reduction of water absorption by rat colon was also observed following neutron irradiation (87%n), with a 50% reduction at 3 Gy. Comparison of this dose-effect curve with the curve obtained following gamma (60)Co-irradiation indicates an RBE of 2.2 for absorptive colonic function in rat calculated at 4 days after exposure.

  5. Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer

    International Nuclear Information System (INIS)

    Aebersold, D.M.; Isaak, B.; Behrensmeier, F.; Kolotas, C.; Mini, R.; Greiner, R.H.; Thalmann, G.; Kranzbuehler, H.

    2004-01-01

    Background and purpose: analyses of permanent brachytherapy seed implants of the prostate have demonstrated that the use of a preplan may lead to a considerable decrease of dosimetric implant quality. The authors aimed to determine whether the same drawbacks of preplanning also apply to high-dose-rate (HDR) brachytherapy. Patients and methods: 15 patients who underwent two separate HDR brachytherapy implants in addition to external-beam radiation therapy for advanced prostate cancer were analyzed. A pretherapeutic transrectal ultrasound was performed in all patients to generate a preplan for the first brachytherapy implant. For the second brachytherapy, a subset of patients were treated by preplans based on the ultrasound from the first brachytherapy implant. Preplans were compared with the respective postplans assessing the following parameters: coverage index, minimum target dose, homogeneity index, and dose exposure of organs at risk. The prostate geometries (volume, width, height, length) were compared as well. Results: at the first brachytherapy, the matching between the preplan and actual implant geometry was sufficient in 47% of the patients, and the preplan could be applied. The dosimetric implant quality decreased considerably: the mean coverage differed by -0.11, the mean minimum target dose by -0.15, the mean homogeneity index by -0.09. The exposure of organs at risk was not substantially altered. At the second brachytherapy, all patients could be treated by the preplan; the differences between the implant quality parameters were less pronounced. The changes of prostate geometry between preplans and postplans were considerable, the differences in volume ranging from -8.0 to 13.8 cm 3 and in dimensions (width, height, length) from -1.1 to 1.0 cm. Conclusion: preplanning in HDR brachytherapy of the prostate is associated with a substantial decrease of dosimetric implant quality, when the preplan is based on a pretherapeutic ultrasound. The implant quality

  6. Bilateral implant reconstruction does not affect the quality of postmastectomy radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Alice Y., E-mail: hoa1234@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Patel, Nisha [Drexel University College of Medicine, Philadelphia, PA (United States); Ohri, Nisha [Department of Radiation Oncology, Mount Sinai School of Medicine, New York, NY (United States); Morrow, Monica [Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Mehrara, Babak J.; Disa, Joseph J.; Cordeiro, Peter G. [Department of Plastic Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Shi, Weiji; Zhang, Zhigang [Department of Biostatistics and Epidemiology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Gelblum, Daphna [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Nerbun, Claire T.; Woch, Katherine M.; Ballangrud, Ase [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); McCormick, Beryl; Powell, Simon N. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2014-04-01

    To determine if the presence of bilateral implants, in addition to other anatomic and treatment-related variables, affects coverage of the target volume and dose to the heart and lung in patients receiving postmastectomy radiation therapy (PMRT). A total of 197 consecutive women with breast cancer underwent mastectomy and immediate tissue expander (TE) placement, with or without exchange for a permanent implant (PI) before radiation therapy at our center. PMRT was delivered with 2 tangential beams + supraclavicular lymph node field (50 Gy). Patients were grouped by implant number: 51% unilateral (100) and 49% bilateral (97). The planning target volume (PTV) (defined as implant + chest wall + nodes), heart, and ipsilateral lung were contoured and the following parameters were abstracted from dose-volume histogram (DVH) data: PTV D{sub 95%} > 98%, Lung V{sub 20}Gy > 30%, and Heart V{sub 25}Gy > 5%. Univariate (UVA) and multivariate analyses (MVA) were performed to determine the association of variables with these parameters. The 2 groups were well balanced for implant type and volume, internal mammary node (IMN) treatment, and laterality. In the entire cohort, 90% had PTV D{sub 95%} > 98%, indicating excellent coverage of the chest wall. Of the patients, 27% had high lung doses (V{sub 20}Gy > 30%) and 16% had high heart doses (V{sub 25}Gy > 5%). No significant factors were associated with suboptimal PTV coverage. On MVA, IMN treatment was found to be highly associated with high lung and heart doses (both p < 0.0001), but implant number was not (p = 0.54). In patients with bilateral implants, IMN treatment was the only predictor of dose to the contralateral implant (p = 0.001). In conclusion, bilateral implants do not compromise coverage of the target volume or increase lung and heart dose in patients receiving PMRT. The most important predictor of high lung and heart doses in patients with implant-based reconstruction, whether unilateral or bilateral, is treatment of

  7. Some characteristics of the retention distribution and internal doses of 59Fe in rats

    International Nuclear Information System (INIS)

    Wang Deheng; Tian Wuxun; Zhang Hongyuan; Wen Quanfa; Hu Yuexin; Zhao Shanyin

    1993-01-01

    After gastric incubation, the whole body 59 Fe-retentions in rats were fit to two compartment exponential equations. The biological half life for 59 Fe in the slow compartment are 95 and 109 days for young and adult rats respectively, not statistically significantly different. The main 59 Fe-accumulative organs are liver and bone marrow. The biological eliminations of 59 Fe from most organs in young rats are faster than in adult rats. The young rats get more total accumulative dose in organs except liver and total body and have a faster dose accumulative speed than the adult rats. Equal quantities of 59 Fe P.O. may probably give young rats more intensive biological effects than adult rats

  8. American brachytherapy society recommends no change for prostate permanent implant dose prescriptions using iodine-125 or palladium-103

    International Nuclear Information System (INIS)

    Rivard, M.J.; Butler, W.M.; Merrick, G.S.; Devlin, P.M.; Hayes, J.K.; Hearn, R.A.; Lief, E.P.; Meigooni, A.S.; Williamson, J.F.

    2008-01-01

    Purpose - In 2004, the American Association of Physicists in Medicine (AAPM) issued a report outlining recommended 125 I and 103 Pd datasets for consistency in calculating brachytherapy dose distributions. In 2005, to aid evaluating the clinical impact of implementing these datasets, the AAPM assessed the historical dependence of how prescribed doses differed from administered doses for 125 I and 103 Pd for permanent implantation of the prostate. Consequently, the American Brachytherapy Society (ABS) considered the nature of these changes towards issuing recommended dose prescriptions for 125 I and 103 Pd interstitial brachytherapy implants for mono-therapy and standard boosts. Methods and materials - An investigation was performed of the 2005 AAPM analysis to determine changes in administered dose while affixing prescribed dose using 2004 AAPM 125 I and 103 Pd brachytherapy dosimetry datasets for prostate implants. For 125 I and 103 Pd, administered dose would change by +1.4% and +4.2%, respectively. The biological and societal impact of changing prescribed dose was considered. Results - Based on the need for clinical constancy and in recognition of overall uncertainties, the ABS recommends immediate implementation of the 2004 AAPM consensus brachytherapy dosimetry datasets and no changes to 125 I and 103 Pd dose prescriptions at this time. Conclusions - Radiation oncologists should continue to prescribe mono-therapy doses of 145 Gy and 125 Gy for 125 I and 105 Pd, respectively, and standard boost doses of 100-110 Gy and 90-100 Gy for 125 I and 103 Pd, respectively. (authors)

  9. Utilizing a Rat Delayed Implantation Model to Teach Integrative Endocrinology and Reproductive Biology

    Science.gov (United States)

    Geisert, Rodney D.; Smith, Michael F.; Schmelzle, Amanda L.; Green, Jonathan A.

    2018-01-01

    In this teaching laboratory, the students are directed in an exercise that involves designing and performing an experiment to determine estrogen's role in regulating delayed implantation (diapause) in female rats. To encourage active participation by the students, a discussion question is provided before the laboratory exercise in which each…

  10. An array of highly flexible electrodes with a tailored configuration locked by gelatin during implantation – initial evaluation in cortex cerebri of awake rats

    Directory of Open Access Journals (Sweden)

    Johan eAgorelius

    2015-09-01

    Full Text Available A major challenge in the field of neural interfaces is to overcome the problem of poor stability of neuronal recordings, which impedes long-term studies of individual neurons in the brain. Conceivably, unstable recordings reflect relative movements between electrode and tissue. To address this challenge, we have developed a new ultra-flexible electrode array and evaluated its performance in awake non-restrained animals.MethodsAn array of eight separated gold leads (4 x10 μm, individually flexible in 3D, were cut from a gold sheet using laser milling and insulated with Parylene C. To provide structural support during implantation into rat cortex, the electrode array was embedded in a hard gelatin based material, which dissolves after implantation. Recordings were made during 3 weeks. At termination, the animals were perfused with fixative and frozen to prevent dislocation of the implanted electrodes. A thick slice of brain tissue, with the electrode array still in situ, was made transparent using methyl salicylate to evaluate the conformation of the implanted electrode array.ResultsMedian noise levels and signal/noise remained relatively stable during the 3 week observation period; 4.3 μV to 5.9 μV and 2.8 to 4.2, respectively. The spike amplitudes were often quite stable within recording sessions and for 15% of recordings where single-units were identified, the highest-SNR unit had an amplitude higher than 150 V. In addition, high correlations (>0.96 between unit waveforms recorded at different time points were obtained for 58% of the electrode sites. The structure of the electrode array was well preserved 3 weeks after implantation.Conclusions A new implantable multichannel neural interface, comprising electrodes individually flexible in 3D that retain its architecture and functionality after implantation has been developed. Since the new neural interface design is adaptable, it offers a versatile tool to explore the function of various

  11. EGF increases expression and activity of PAs in preimplantation rat embryos and their implantation rate

    Directory of Open Access Journals (Sweden)

    Har-Vardi Iris

    2007-01-01

    Full Text Available Abstract Background Embryo implantation plays a major role in embryogenesis and the outcome of pregnancy. Plasminogen activators (PAs have been implicated in mammalian fertilization, early stages of development and embryo implantation. As in-vitro developing embryos resulted in lower implantation rate than those developed in-vivo we assume that a reduced PAs activity may be involved. In the present work we studied the effect of EGF on PAs activity, quantity and embryo implantation. Methods Zygotes were flushed from rat oviducts on day one of pregnancy and grown in-vitro in R1ECM supplemented with EGF (10 ng/ml and were grown up to the blastocyst stage. The control groups were grown in the same medium without EGF. The distribution and quantity of the PAs were examined using fluorescence immunohistochemistry followed by measurement of PAs activity using the chromogenic assay. Implantation rate was studied using the embryo donation model. Results PAs distribution in the embryos was the same in EGF treated and untreated embryos. Both PAs were localized in the blastocysts' trophectoderm, supporting the assumption that PAs play a role in the implantation process in rats. EGF increased the quantity of uPA at all stages studied but the 8-cell stage as compared with controls. The tissue type PA (tPA content was unaffected except the 8-cell stage, which was increased. The activity of uPA increased gradually towards the blastocyst stage and more so due to the presence of EGF. The activity of tPA did not vary with the advancing developmental stages although it was also increased by EGF. The presence of EGF during the preimplantation development doubled the rate of implantation of the treated group as compared with controls.

  12. Does prostate brachytherapy treat the seminal vesicles? A dose-volume histogram analysis of seminal vesicles in patients undergoing combined PD-103 prostate implantation and external beam irradiation

    International Nuclear Information System (INIS)

    Stock, Richard G.; Lo, Yeh-Chi; Gaildon, Mohamoud; Stone, Nelson N.

    1999-01-01

    Purpose: Combined brachytherapy of the prostate and external beam irradiation (EBRT) of the prostate and seminal vesicles (SV) is becoming a popular treatment for high-risk prostate cancer. Dose-volume histogram (DVH) analysis of the SV in patients undergoing this treatment was performed to determine the dose distribution to the SV and the adequacy of this treatment in patients with potential SV involvement. Methods and Materials: Twenty-five consecutive patients were treated with a Pd-103 implant of the prostate alone and 45 Gy of EBRT to the prostate and SV. Attempts were not made to implant the SV but seeds were routinely placed at the junction of the prostate and SV. All patients underwent CT-based post implant dosimetric analysis 1 month after implantation. As part of this analysis, DVH were generated for the prostate and total SV volume (SVT). In addition, the SV was divided into 6-mm-thick volumes identified as SV1, SV2, SV3, SV4, and SV5 starting from the junction of the prostate and SV and extending distally. DVH were also generated for these structures. Delivered dose was defined as the D90 (dose delivered to 90% of the organ on DVH). Results: The median volumes in cc of the prostate, SVT, SV1, SV2, SV3, SV4, and SV5 were 34.33, 9.75, 2.7, 3.48, 2.92, 3.18, and 1.96 respectively. The SVT contained from 0-9 seeds (median 2). There was little dose delivered to the SVT and SV volumes from the implanted prostate. The median D90 values for the prostate, SVT, SV1, SV2, SV3, SV4, and SV5 were 8615 cGy, 675 cGy, 3100 cGy, 1329 cGy, 553 cGy, 246 cGy, and 67 cGy, respectively. The dose delivered to the prostate covered small percentages of SV. The percents of SV volumes covered by the prostate D90 were 11, 35, 3.3, 0, 0, and 0 for SVT, SV1, SV2, SV3, SV4, and SV5, respectively. Conclusions: DVH analysis of the SV reveals that dose generated from an implanted prostate contributes little to the SV. Those patients at high risk for SV involvement may be under treated

  13. Effect of low doses of gamma radiation on barley tolerance grown under saline conditions

    International Nuclear Information System (INIS)

    Charbaji, T.; Khalifa, Kh; Al-Ain, F.

    2003-01-01

    A field experiment was conducted at Al-Hijanah, an area located at about 35 km south east of Damascus. Seeds of two barley varieties [White Arabi (WA) and Pakistani 30163 (PK) were irradiated with 2 doses 0 and 15 Gy of gamma irradiation. Then, they were shown on salty soil (17.6-18,9 m mos/cm) and irrigated with salty water (5.12-5.75 m mos/cm). A dose of 15 Gy of gamma irradiation was shown to positively affect the percent germination of PK but had no similar effect on WA. The results were obtained at 3 different growth stages: first, the heading stage, 15 Gy dose increased shoots dry weight, Mg ++ , P content and percent of WA, whereas N percent of PK was decreased. When the seeds were irradiated by the same dose. K + content in WA was significantly higher than that in PK. Second, physiological maturity stage, the same dose (15 Gy) increased shoot dry, but affected negatively K + and Na + contents in PK variety. As for WA variety, Mg ++ and P contents were increased, whereas Na + and Cl - were slightly decreased. Third, harvest stage, gamma irradiation had a positive effect on total yield, grain yield, nitrogen yield and harvest index of PK variety. A positive effect was produced on straw yield, 1000-grain weight, and nitrogen yield of WA variety. (author)

  14. High-energy ion implantation of materials

    International Nuclear Information System (INIS)

    Williams, J.M.

    1991-11-01

    High-energy ion implantation is an extremely flexible type of surface treatment technique, in that it offers the possibility of treating almost any type of target material or product with ions of almost any chemical species, or combinations of chemical species. In addition, ion implantations can be combined with variations in temperature during or after ion implantation. As a result, the possibility of approaching a wide variety of surface-related materials science problems exists with ion implantation. This paper will outline factors pertinent to application of high-energy ion implantation to surface engineering problems. This factors include fundamental advantages and limitations, economic considerations, present and future equipment, and aspects of materials science

  15. WA18

    CERN Multimedia

    1977-01-01

    Front view. The target plates are cut from marble (3x3 m slabs surrounded by magnetized iron) and allow the use of the calorimeter as a muon polarimeter. WA18 was CHARM, the experiment of the CERN-Hamburg-Amsterdam-Rome(INFN)-Moskow(ITEP) Collaboration

  16. High-dose stabilized chlorite matrix WF10 prolongs cardiac xenograft survival in the hamster-to-rat model without inducing ultrastructural or biochemical signs of cardiotoxicity

    DEFF Research Database (Denmark)

    Hansen, A; Kemp, K; Kemp, E

    2001-01-01

    of high dose WF10 as a single drug regimen in the hamster-to-rat xenotransplantation model and searched for possible cardiotoxic side effects. WF10 prolonged cardiac xenograft survival, but did not induce tolerence or inhibit pathological signs of acute rejection. Hamsters from the donor population...

  17. High-dose dextromethorphan produces myelinoid bodies in the hippocampus of rats.

    Science.gov (United States)

    Tran, Hai-Quyen; Chung, Yoon Hee; Shin, Eun-Joo; Kim, Won Ki; Lee, Jae-Chul; Jeong, Ji Hoon; Wie, Myung Bok; Jang, Choon-Gon; Yamada, Kiyofumi; Nabeshima, Toshitaka; Kim, Hyoung-Chun

    2016-10-01

    Dextromethorphan (DM) administered at supra-antitussive doses produce psychotoxic and neurotoxic effects in humans. We administered DM (80 mg/kg) to rats intraperitoneally to determine the ultrastructural change induced by DM, because intraperitoneal route is sensitive for the behavioral responses. Treatment with DM resulted in mitochondrial dysfunction and formation of myelinoid bodies in the hippocampus. MK-801 [(+)-5-methyl-10,11-dihydro-5H-dibenzo[a,d]cyclohepten-5,10-imine maleate] attenuated DM-induced cytosolic oxidative burdens. However, neither MK-801 nor naloxone affected DM-induced mitochondrial dysfunction and formation of myelinoid bodies, indicating that the neurotoxic mechanism needs to be further elucidated. Therefore, the spectrum of toxicological effects associated with DM need to be reassessed. Copyright © 2016 The Authors. Production and hosting by Elsevier B.V. All rights reserved.

  18. Radiotherapy and risk of implantable cardioverter-defibrillator malfunctions: experimental data from direct exposure at increasing doses.

    Science.gov (United States)

    Zecchin, Massimo; Artico, Jessica; Morea, Gaetano; Severgnini, Mara; Bianco, Elisabetta; De Luca, Antonio; Fantasia, Anna Zorzin; Salvatore, Luca; Milan, Vittorino; Lucarelli, Matteo; Dissegna, Roberta; Cannatà, Antonio; Sinagra, Gianfranco

    2018-04-01

    During radiotherapy, in patients with implantable cardioverter-defibrillators (ICDs) malfunctions are considered more likely if doses more than 2 Gy reach the ICD site; however, most malfunctions occur with high-energy (>10 MV) radiations, and the risk is less defined using 6-MV linear accelerators. The purpose of the study is to experimentally evaluate the occurrence of malfunctions in ICDs radiated with a 6-MV linear accelerator at increasing photon doses. Thirty-two ICDs from all manufacturers (31 explanted and one demo) were evaluated; all devices with a sufficient battery charge underwent multiple radiations with a 6-MV photon beam reaching a cumulative dose at ICD site of 0.5, 1, 2, 3, 5 and 10 Gy and interrogated after every session. All antitachycardia therapies were left enabled; two ICDs were connected to a rhythm simulator (one simulating a complete atrioventricular block without ventricular activity) and visually monitored by external ECG and the ICD programmer during radiation. Thirteen ICDs were excluded before radiation because of battery depletion; after radiation up to the cumulative dose at the cardiac implantable electronic device site of 10 Gy, in the remaining 19 devices, programmation and battery charge remained unchanged and no switch to safety mode was observed; oversensing, pacing inhibition or inappropriate antitachycardia therapy were neither recorded nor visually observed during radiation. With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.

  19. Systemic Assessment of Calcium and Phosphorus Level after Implantation of Porous Iron in Rats

    Science.gov (United States)

    Siallagan, S. F.; Amelia, F.; Utami, N. D.; Ulum, M. F.; Boediono, A.; Estuningsih, S.; Hermawan, H.; Noviana, D.

    2017-07-01

    One of important aspects in bone healing process is physiological level of calcium (Ca), and phosphorus (P) that can be altered by implantation of biodegradable porous iron. Therefore, this study aims to investigate the concentration of Ca, P and Ca/P ratio in the peripheral blood during the implantation period up to 4 months. Forty adult male Sprague Dawley rats were used and divided into 3 groups receiving different pore size of iron implants (pore size 450, 580, 800μm) and one group of sham. The implants (5x2x0.5mm) were inserted into flat bone defects at latero-medial of femoral bone. Blood sample was taken from ventral tail artery before and after 4 month of implantation. Calcium and P concentrations in the blood were determined by BA-88A Semi-Auto Chemistry Analyzer. Results showed that concentration of Ca and P are slightly higher after implantation than before implantation, except for the 450μm group. The Ca/P ratio before and after implantation was increased in the sham group, and decreased in the 450 and 800μm groups. Concentration of Ca, P and Ca/P ratio insignificantly change between before and 4 months after surgery in some groups.

  20. Intramyocardial implantation of differentiated rat bone marrow mesenchymal stem cells enhanced by TGF-β1 improves cardiac function in heart failure rats

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Y. [Department of Histology and Embryology, Hebei Medical University, Shijiazhuang, Hebei (China); Liu, B. [Department of Pathology, the First Affiliated Hospital of Hebei North University, Zhangjiakou, Hebei (China); Wang, H.P. [Department of Histology and Embryology, Hebei North University, Zhangjiakou, Hebei (China); Zhang, L. [Department of Histology and Embryology, Hebei Medical University, Shijiazhuang, Hebei (China)

    2016-05-31

    The present study tested the hypotheses that i) transforming growth factor beta 1 (TGF-β1) enhances differentiation of rat bone marrow mesenchymal stem cells (MSCs) towards the cardiomyogenic phenotype and ii) intramyocardial implantation of the TGF-β1-treated MSCs improves cardiac function in heart failure rats. MSCs were treated with different concentrations of TGF-β1 for 72 h, and then morphological characteristics, surface antigens and mRNA expression of several transcription factors were assessed. Intramyocardial implantation of these TGF-β1-treated MSCs to infarcted heart was also investigated. MSCs were initially spindle-shaped with irregular processes. On day 28 after TGF-β1 treatment, MSCs showed fusiform shape, orientating parallel with one another, and were connected with adjoining cells forming myotube-like structures. Immunofluorescence revealed the expression of cardiomyocyte-specific proteins, α-sarcomeric actin and troponin T, in these cells. The mRNA expression of GATA4 and Nkx2.5 genes was slightly increased on day 7, enhanced on day 14 and decreased on day 28 while α-MHC gene was not expressed on day 7, but expressed slightly on day 14 and enhanced on day 28. Transmission electron microscopy showed that the induced cells had myofilaments, z line-like substances, desmosomes, and gap junctions, in contrast with control cells. Furthermore, intramyocardial implantation of TGF-β1-treated MSCs to infarcted heart reduced scar area and increased the number of muscle cells. This structure regeneration was concomitant with the improvement of cardiac function, evidenced by decreased left ventricular end-diastolic pressure, increased left ventricular systolic pressure and increased maximal positive pressure development rate. Taken together, these results indicate that intramyocardial implantation of differentiated MSCs enhanced by TGF-β1 improved cardiac function in heart failure rats.

  1. Intramyocardial implantation of differentiated rat bone marrow mesenchymal stem cells enhanced by TGF-β1 improves cardiac function in heart failure rats

    International Nuclear Information System (INIS)

    Lv, Y.; Liu, B.; Wang, H.P.; Zhang, L.

    2016-01-01

    The present study tested the hypotheses that i) transforming growth factor beta 1 (TGF-β1) enhances differentiation of rat bone marrow mesenchymal stem cells (MSCs) towards the cardiomyogenic phenotype and ii) intramyocardial implantation of the TGF-β1-treated MSCs improves cardiac function in heart failure rats. MSCs were treated with different concentrations of TGF-β1 for 72 h, and then morphological characteristics, surface antigens and mRNA expression of several transcription factors were assessed. Intramyocardial implantation of these TGF-β1-treated MSCs to infarcted heart was also investigated. MSCs were initially spindle-shaped with irregular processes. On day 28 after TGF-β1 treatment, MSCs showed fusiform shape, orientating parallel with one another, and were connected with adjoining cells forming myotube-like structures. Immunofluorescence revealed the expression of cardiomyocyte-specific proteins, α-sarcomeric actin and troponin T, in these cells. The mRNA expression of GATA4 and Nkx2.5 genes was slightly increased on day 7, enhanced on day 14 and decreased on day 28 while α-MHC gene was not expressed on day 7, but expressed slightly on day 14 and enhanced on day 28. Transmission electron microscopy showed that the induced cells had myofilaments, z line-like substances, desmosomes, and gap junctions, in contrast with control cells. Furthermore, intramyocardial implantation of TGF-β1-treated MSCs to infarcted heart reduced scar area and increased the number of muscle cells. This structure regeneration was concomitant with the improvement of cardiac function, evidenced by decreased left ventricular end-diastolic pressure, increased left ventricular systolic pressure and increased maximal positive pressure development rate. Taken together, these results indicate that intramyocardial implantation of differentiated MSCs enhanced by TGF-β1 improved cardiac function in heart failure rats

  2. Characterization of a Polymer-Based, Fully Organic Prosthesis for Implantation into the Subretinal Space of the Rat.

    Science.gov (United States)

    Antognazza, Maria Rosa; Di Paolo, Mattia; Ghezzi, Diego; Mete, Maurizio; Di Marco, Stefano; Maya-Vetencourt, José Fernando; Maccarone, Rita; Desii, Andrea; Di Fonzo, Fabio; Bramini, Mattia; Russo, Angela; Laudato, Lucia; Donelli, Ilaria; Cilli, Michele; Freddi, Giuliano; Pertile, Grazia; Lanzani, Guglielmo; Bisti, Silvia; Benfenati, Fabio

    2016-09-01

    Replacement strategies arise as promising approaches in case of inherited retinal dystrophies leading to blindness. A fully organic retinal prosthesis made of conjugated polymers layered onto a silk fibroin substrate is engineered. First, the biophysical and surface properties are characterized; then, the long-term biocompatibility is assessed after implantation of the organic device in the subretinal space of 3-months-old rats for a period of five months. The results indicate a good stability of the subretinal implants over time, with preservation of the physical properties of the polymeric layer and a tight contact with the outer retina. Immunoinflammatory markers detect only a modest tissue reaction to the surgical insult and the foreign body that peaks shortly after surgery and progressively decreases with time to normal levels at five months after implantation. Importantly, the integrity of the polymeric layer in direct contact with the retinal tissue is preserved after five months of implantation. The recovery of the foreign-body tissue reaction is also associated with a normal b-wave in the electroretinographic response. The results demonstrate that the device implanted in nondystrophic eyes is well tolerated, highly biocompatible, and suitable as retinal prosthesis in case of photoreceptor degeneration. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  4. High-Dose-Rate Brachytherapy of a Single Implant With Two Fractions Combined With External Beam Radiotherapy for Hormone-Naive Prostate Cancer

    International Nuclear Information System (INIS)

    Sato, Morio; Mori, Takashi; Shirai, Shintaro; Kishi, Kazushi; Inagaki, Takeshi; Hara, Isao

    2008-01-01

    Purpose: To evaluate the preliminary outcomes of high-dose-rate (HDR) brachytherapy of a single implant with two fractions and external beam radiotherapy (EBRT) for hormone-naive prostate cancer. Methods and Materials: Between March 2000 and Sept 2003, a total of 53 patients with tumor Stage T1c-T3b N0 M0 prostate cancer were treated with HDR brachytherapy boost doses (7.5 Gy/fraction) and 50-Gy EBRT during a 5.5-week period. Median follow-up was 61 months. Patients were divided into groups with localized (T1c-T2b) and advanced disease (T3a-T3b). We used the American Society for Therapeutic Radiology and Oncology (ASTRO) definition for biochemical failure. According to recommendations of the Radiation Therapy Oncology Group-ASTRO Phoenix Consensus Conference, biochemical failure-free control rates (BF-FCRs) at 3 years were investigated as 2 years short of the median follow-up. Results: Between April 2000 and Sept 2007, Common Terminology Criteria for Adverse Events Version 2.0 late Grade 2 genitourinary and gastrointestinal toxicity rates were 0% and 3.8%, respectively. Erectile preservation was 25% at 5 years. Overall survival was 88.1% and cause-specific survival was 100%. At 3 years, ASTRO BF-FCRs of the localized and advanced groups were 100% and 42%, respectively (p = 0.001). Conclusions: The HDR brachytherapy of a single implant with two fractions plus EBRT is effective in treating patients with localized hormone-naive prostate cancer, with the least genitourinary and gastrointestinal toxicities; however, longer median BF-FCR follow-up is required to assess these findings

  5. Muundo wa Mashairi katika Diwani ya Mnyampala (1965) na Nafasi ...

    African Journals Online (AJOL)

    Makala hii pia inadadisi namna mbinu za kimuundo zilivyofanikisha usawiri na ubainishaji wa falsafa ya mtunzi kuhusu ushairi wa Kiswahili na nafasi ya ushairi katika jamii. Makala imeanza kwa kugusia usuli wa historia ya ushairi wa Kiswahili, historia fupi ya maisha ya Mathias Mnyampala na nadharia yake kuhusu ...

  6. Study on interstitial brachytherapy using 103Pd seeds on tumor-bearing rats

    International Nuclear Information System (INIS)

    Feng Huiru; Zhang Jingming; Tian Jiahe; Ding Weimin; Bai Hongsheng; Jin Xiaohai

    2003-01-01

    The effects of low-dose-rate brachytherapy are investigated in tumor-bearing rat. Walker 256 cells are transplanted subcutaneously with a trocar in the left leg of rats (Wistar). Two weeks later, rats with a tumor of 10 mm in mean diameter are divided into three groups (10 per group). Two groups are given 1 seed and 2 seeds implantation of 103 Pd, respectively, the third group is as an untreated control. Tumor size is measured twice a week until the 25th day when the rats are killed. Tumor is monitored either by palpation or further confirmed by histopathology. Kaplan-Meier statistic method is performed for survival analysis. The results show that the average weight of rats in untreated group is lower than in radiation groups (P 0.05). Tumor volumes in all treatment groups increase more obviously than in control till 16 days post-implantation. Tumor regression rate in 1 seed group is higher than in control group and in 2 seeds group. Although survival analysis show that the median survival time in 1 seed, 2 seeds and control groups are 24±0, 21±2 and 19±2 days with survival rate of 80%, 60% and 50% respectively, no significant differences are seen in all groups. So, brachytherapy with 103 Pd seed is effective on tumor-bearing rats. The implantation of seed can cause tumor edema in a self-limited way. A reasonable doses chosen for brachytherapy may play a role in treatment success

  7. The effect of formoterol on peritoneal VEGF levels in rats with endometriosis.

    Science.gov (United States)

    Yilmaz, Nafiye; Ozaksit, Gulnur; Keskin, Raziye; Tapisiz, Omer; Mollamahmutoglu, Leyla; Uysal, Sema; Astarci, Muzeyyen; Ustun, Huseyin; Mulazımoglu, Baris

    2012-04-01

    The aim of this study is to investigate the effect of formoterol (β2 adrenergic receptor agonist) on peritoneal VEGF levels in rats with endometriosis. Experimental endometriosis was constituted with implantation of endometrial tissue. The implants were examined by second laparatomy and rats were divided randomly into four groups. One cc saline was applied ip to the control (C) group (n=8) daily, 22.5μg/kg/day ip formoterol was applied to the second (F) group (n=10) daily, 22.5μg/kg/day ip formoterol and 10mg/kg/day ip propranolol were applied to the third (FP) group (n=10) daily, 45μg/kg/day ip formoterol was applied to the fourth (FF) group (n=9). Before treatment and after 30 days treatment period, peritoneal VEGF levels, the volumes and histopathological properties of the implants were evaluated. There were significant differences in between the peritoneal VEGF levels before and after treatment in group 2(F) and group 4(FF) (p(a): 0.01, 0.01 respectively). But there were no significant changes in between the volumes of implants before and after treatment among the groups (p>0.05). There were no significant differences among the groups in histopathological parameters (p>0.05). Formoterol treatment was seen to have no effect on the volumes and histopathological structure of endometriotic implants in our study. On the other hand, based on the group 2(F) and 4's (FF) VEGF levels after the treatment, low dose or high dose formoterol may be effective with long term therapy. Formoterol may reduce the development of endometriosis. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Riwaya ya Kiswahili katika ufundishaji wa historia | Mlaga | Kiswahili

    African Journals Online (AJOL)

    Makala haya yanachunguza uwezekano wa riwaya ya Kiswahili kutumika katika ufundishaji wa historia. Makala yamejiegemeza katika kuonesha namna ambavyo riwaya kama utanzu mmojawapo wa fasihi unafaa kufundishia historia. Hivyo basi, hoja mbalimbali zinabainishwa ili kuonesha namna ambavyo riwaya ya ...

  9. Method of localization and implantation of the lumpectomy site for high dose rate brachytherapy after conservative surgery for T1 and T2 breast cancer

    International Nuclear Information System (INIS)

    Perera, F.; Chisela, F.; Engel, J.; Venkatesan, V.

    1995-01-01

    Purpose: This article describes our technique of localization and implantation of the lumpectomy site of patients with T1 and T2 breast cancer. Our method was developed as part of our Phase I/II pilot study of high dose rate (HDR) brachytherapy alone after conservative surgery for early breast cancer. Methods and Materials: In March 1992, we started a pilot study of HDR brachytherapy to the lumpectomy site as the sole radiotherapy after conservative surgery for clinical T1 or T2 invasive breast cancer. Initially, the protocol required intraoperative placement of the interstitial needles at the time of definitive surgery to the breast. The protocol was then generalized to allow the implantation of the lumpectomy site after definitive surgery to the breast, either at the time of subsequent axillary nodal dissection or postoperatively. To date, five patients have been implanted intraoperatively at the time of definitive breast surgery. Twelve patients were implanted after definitive breast surgery, with 7 patients being done at the time of axillary nodal dissection and 5 patients postoperatively. We devised a method of accurately localizing and implanting the lumpectomy site after definitive breast surgery. The method relies on the previous placement of surgical clips by the referring surgeon to mark the lumpectomy site. For each patient, a breast mold is made with radio-opaque angiocatheters taped onto the mold in the supero-inferior direction. A planning CT scan is then obtained through the lumpectomy site. The volume of the lumpectomy site, the number of implant planes necessary, and the orientation of the implants are then determined from the CT scan. The angiocatheters provide a reference grid on the CT films to locate the entry and exit points of the interstitial needles on the plastic mold. The entry and exit points for reference needles are then transferred onto the patient's skin enabling implantation of the lumpectomy site. Needle positions with respect to

  10. SU-F-T-314: Estimation of Dose Distributions with Different Types of Breast Implants in Various Radiation Treatment Techniques for Breast Cancer

    International Nuclear Information System (INIS)

    Lee, M; Lee, S; Suh, T; Jung, J; Kim, S; Cho, Y; Lee, I

    2016-01-01

    Purpose: This study investigates the effects of different kinds and designs of commercialized breast implants on the dose distributions in breast cancer radiotherapy under a variety of conditions. Methods: The dose for the clinical conventional tangential irradiation, Intensity Modulated Radiation Therapy (IMRT), volumetric modulated arc therapy (VMAT) breast plans was measured using radiochromic films and stimulated luminescence dosimeter (OSLD). The radiochromic film was used as an integrating dosimeter, while the OSLDs were used for real-time dosimetry to isolate the contribution of dose from individual segment. The films were placed at various slices in the Rando phantom and between the body and breast surface OSLDs were used to measure skin dose at 18 positions spaced on the two (right/left) breast. The implant breast was placed on the left side and the phantom breast was remained on the right side. Each treatment technique was performed on different size of the breasts and different shape of the breast implant. The PTV dose was prescribed 50.4 Gy and V47.88≥95%. Results: In different shapes of the breast implant, because of the shadow formed extensive around the breast implant, dose variation was relatively higher that of prescribed dose. As the PTV was delineated on the whole breast, maximum 5% dose error and average 3% difference was observed averagely. VMAT techniques largely decrease the contiguous hot spot in the skin by an average of 25% compared with IMRT. The both IMRT and VMAT techniques resulted in lower doses to normal critical structures than tangential plans for nearly all dose analyzation. Conclusion: Compared to the other technique, IMRT reduced radiation dose exposure to normal tissues and maintained reasonable target homogeneity and for the same target coverage, VMAT can reduce the skin dose in all the regions of the body.

  11. SU-F-T-314: Estimation of Dose Distributions with Different Types of Breast Implants in Various Radiation Treatment Techniques for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M; Lee, S; Suh, T [Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Jung, J [Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Department of Radiation Oncology, College of Medicine, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Kim, S; Cho, Y; Lee, I [Department of Radiation Oncology, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: This study investigates the effects of different kinds and designs of commercialized breast implants on the dose distributions in breast cancer radiotherapy under a variety of conditions. Methods: The dose for the clinical conventional tangential irradiation, Intensity Modulated Radiation Therapy (IMRT), volumetric modulated arc therapy (VMAT) breast plans was measured using radiochromic films and stimulated luminescence dosimeter (OSLD). The radiochromic film was used as an integrating dosimeter, while the OSLDs were used for real-time dosimetry to isolate the contribution of dose from individual segment. The films were placed at various slices in the Rando phantom and between the body and breast surface OSLDs were used to measure skin dose at 18 positions spaced on the two (right/left) breast. The implant breast was placed on the left side and the phantom breast was remained on the right side. Each treatment technique was performed on different size of the breasts and different shape of the breast implant. The PTV dose was prescribed 50.4 Gy and V47.88≥95%. Results: In different shapes of the breast implant, because of the shadow formed extensive around the breast implant, dose variation was relatively higher that of prescribed dose. As the PTV was delineated on the whole breast, maximum 5% dose error and average 3% difference was observed averagely. VMAT techniques largely decrease the contiguous hot spot in the skin by an average of 25% compared with IMRT. The both IMRT and VMAT techniques resulted in lower doses to normal critical structures than tangential plans for nearly all dose analyzation. Conclusion: Compared to the other technique, IMRT reduced radiation dose exposure to normal tissues and maintained reasonable target homogeneity and for the same target coverage, VMAT can reduce the skin dose in all the regions of the body.

  12. High-dose regions versus likelihood of cure after prostate brachytherapy

    International Nuclear Information System (INIS)

    Wallner, Kent; Merrick, Gregory; Sutlief, Steven; True, Laurence; Butler, Wayne

    2005-01-01

    Purpose: To analyze the effect of high-dose regions on biochemical cancer control rates after prostate brachytherapy. Methods and Materials: Patients with 1997 American Joint Committee on Cancer clinical Stage T1c-T2a prostate carcinoma (Gleason grade 5-6, prostate-specific antigen level 4-10 ng/mL) were randomized to implantation with 125 I (144 Gy) vs. 103 Pd (125 Gy, National Institute of Standards and Technology 1999). Isotope implantation was performed by standard techniques, using a modified peripheral loading pattern. Of the 313 patients entered in the protocol, 270 were included in this analysis. The 125 I source strength ranged from 0.4 to 0.89 mCi (median, 0.55 mCi), and the 103 Pd source strength ranged from 1.3 to 1.6 mCi (median, 1.5 mCi). CT was performed within 4 h after implantation. The dosimetric parameters analyzed included the percentage of the postimplant prostate volume covered by the 100%, 150%, 200%, and 300% prescription dose (V 100 , V 150 , V 200 , and V 300 , respectively). The median time to the last follow-up for patients without failure was 2.7 years. Freedom from biochemical failure was defined as a serum prostate-specific antigen level of ≤0.5 ng/mL at last follow-up. Patients were censored at last follow-up if their serum prostate-specific antigen level was still decreasing. Results: The mean V 100 , V 150 , V 200 , and V 300 value was 90% (±8%), 63% (±14), 35% (±13%), and 14% (±7%), respectively. Patients with a V 100 of ≥90% had a 3-year freedom from biochemical failure rate of 96% vs. 87% for those with a V 100 of 100 of ≥90% were analyzed, no relationship was found between higher dose regions and the likelihood of cancer control. This lack of effect on biochemical control was apparent for both isotopes. Conclusion: High-dose regions do not appear to affect cancer control rates, as long as >90% of the prostate volume is covered by the prescription dose

  13. Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator

    International Nuclear Information System (INIS)

    Chen Peng; An Zhenghua; Zhu Ming; Fu, Ricky K.Y.; Chu, Paul K.; Montgomery, Neil; Biswas, Sukanta

    2004-01-01

    The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10 14 cm -2 ) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure

  14. Interim report of image-guided conformal high-dose-rate brachytherapy for patients with unfavorable prostate cancer: the William Beaumont Phase II dose-escalating trial

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Kestin, Larry L.; Stromberg, Jannifer S.; Gonzalez, Jose A.; Wallace, Michelle; Gustafson, Gary S.; Edmundson, Gregory K.; Spencer, William; Vicini, Frank A.

    2000-01-01

    Purpose: We analyzed our institution's experience treating patients with unfavorable prostate cancer in a prospective Phase II dose-escalating trial of external beam radiation therapy (EBRT) integrated with conformal high-dose-rate (HDR) brachytherapy boosts. This interim report discusses treatment outcome and prognostic factors using this treatment approach. Methods and Materials: From November 1991 through February 1998, 142 patients with unfavorable prostate cancer were prospectively treated in a dose-escalating trial with pelvic EBRT in combination with outpatient HDR brachytherapy at William Beaumont Hospital. Patients with any of the following characteristics were eligible: pretreatment prostate-specific antigen (PSA) ≥ 10.0 ng/ml, Gleason score ≥ 7, or clinical stage T2b or higher. All patients received pelvic EBRT to a median total dose of 46.0 Gy. Pelvic EBRT was integrated with ultrasound-guided transperineal conformal interstitial iridium-192 HDR implants. From 1991 to 1995, 58 patients underwent three conformal interstitial HDR implants during the first, second, and third weeks of pelvic EBRT. After October 1995, 84 patients received two interstitial implants during the first and third weeks of pelvic EBRT. The dose delivered via interstitial brachytherapy was escalated from 5.50 Gy to 6.50 Gy for each implant in those patients receiving three implants, and subsequently, from 8.25 Gy to 9.50 Gy per fraction in those patients receiving two implants. To improve implant quality and reduce operator dependency, an on-line, image-guided interactive dose optimization program was utilized during each HDR implant. No patient received hormonal therapy unless treatment failure was documented. The median follow-up was 2.1 years (range: 0.2-7.2 years). Biochemical failure was defined according to the American Society for Therapeutic Radiology and Oncology Consensus Panel definition. Results: The pretreatment PSA level was ≥ 10.0 ng/ml in 51% of patients. The

  15. Metabolomics reveals dose effects of low-dose chronic exposure to uranium in rats: identification of candidate biomarkers in urine samples.

    Science.gov (United States)

    Grison, Stéphane; Favé, Gaëlle; Maillot, Matthieu; Manens, Line; Delissen, Olivia; Blanchardon, Éric; Dublineau, Isabelle; Aigueperse, Jocelyne; Bohand, Sandra; Martin, Jean-Charles; Souidi, Maâmar

    2016-01-01

    Data are sparse about the potential health risks of chronic low-dose contamination of humans by uranium (natural or anthropogenic) in drinking water. Previous studies report some molecular imbalances but no clinical signs due to uranium intake. In a proof-of-principle study, we reported that metabolomics is an appropriate method for addressing this chronic low-dose exposure in a rat model (uranium dose: 40 mg L -1 ; duration: 9 months, n = 10). In the present study, our aim was to investigate the dose-effect pattern and identify additional potential biomarkers in urine samples. Compared to our previous protocol, we doubled the number of rats per group (n = 20), added additional sampling time points (3 and 6 months) and included several lower doses of natural uranium (doses used: 40, 1.5, 0.15 and 0.015 mg L -1 ). LC-MS metabolomics was performed on urine samples and statistical analyses were made with SIMCA-P+ and R packages. The data confirmed our previous results and showed that discrimination was both dose and time related. Uranium exposure was revealed in rats contaminated for 9 months at a dose as low as 0.15 mg L -1 . Eleven features, including the confidently identified N1-methylnicotinamide, N1-methyl-2-pyridone-5-carboxamide and 4-hydroxyphenylacetylglycine, discriminated control from contaminated rats with a specificity and a sensitivity ranging from 83 to 96 %, when combined into a composite score. These findings show promise for the elucidation of underlying radiotoxicologic mechanisms and the design of a diagnostic test to assess exposure in urine, in a dose range experimentally estimated to be above a threshold between 0.015 and 0.15 mg L -1 .

  16. Improvement of attention with amphetamine in low- and high-performing rats.

    Science.gov (United States)

    Turner, Karly M; Burne, Thomas H J

    2016-09-01

    Attentional deficits occur in a range of neuropsychiatric disorders, such as schizophrenia and attention deficit hyperactivity disorder. Psychostimulants are one of the main treatments for attentional deficits, yet there are limited reports of procognitive effects of amphetamine in preclinical studies. Therefore, task development may be needed to improve predictive validity when measuring attention in rodents. This study aimed to use a modified signal detection task (SDT) to determine if and at what doses amphetamine could improve attention in rats. Sprague-Dawley rats were trained on the SDT prior to amphetamine challenge (0.1, 0.25, 0.75 and 1.25 mg/kg). This dose range was predicted to enhance and disrupt cognition with the effect differing between individuals depending on baseline performance. Acute low dose amphetamine (0.1 and 0.25 mg/kg) improved accuracy, while the highest dose (1.25 mg/kg) significantly disrupted performance. The effects differed for low- and high-performing groups across these doses. The effect of amphetamine on accuracy was found to significantly correlate with baseline performance in rats. This study demonstrates that improvement in attentional performance with systemic amphetamine is dependent on baseline accuracy in rats. Indicative of the inverted U-shaped relationship between dopamine and cognition, there was a baseline-dependent shift in performance with increasing doses of amphetamine. The SDT may be a useful tool for investigating individual differences in attention and response to psychostimulants in rodents.

  17. Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Marczak, Alana; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2017-09-15

    The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose 180° acquisition protocol versus a conventional 360° acquisition protocol. Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: 360° and 180° cone-beam computed tomography (CBCT) acquisition protocols. A small-volume 180° CBCT scan and a 360° CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up 360° CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intra-rater agreement. In this ex vivo study, we found that the 180° rotational acquisition was as effective as the conventional 360° rotational acquisition for the preoperative evaluation of potential mini-implant sites.

  18. SR-TXRF analysis of trace elements in whole blood and heart of rats: effects of irradiation with low and high doses

    Science.gov (United States)

    Mota, C. L.; Pickler, A.; Braz, D.; Barroso, R. C.; Mantuano, A.; Salata, C.; Ferreira-Machado, S. C.; Lau, C. C.; de Almeida, C. E.

    2018-04-01

    In the last decades, studies showed that the exposure to low doses of ionizing radiation of the body could sense and activate the cell signaling pathways needed to respond to any induced cellular damage. This procedure reduces cell killing compared with a single dose of high radiation dose. Damage to the vasculature can affect the function of most body organs by restricting blood flow and oxygen to tissues; however, the heart and brain are of main concern. The precise relationship between long-term health effects and low-dose exposures remain poorly understood. Biological markers are powerful tools that can be used to determine dose- response relationships and to estimate risk, especially when dealing with, the effects of low dose exposures in humans. These markers should be specific, sensitive, as well as easy and fast to quantify. Various types of biologic specimens are potential candidates for identifying biomarkers but blood has the advantage of being minimally invasive to obtain. In this study, we propose to apply total reflection X-ray fluorescence to quantify possible chemical elemental concentration (sulfer, iron, zinc, potassium and calcium) changes in blood and heart tissues of Wistar rats after total body irradiation with low (0.1 Gy) and high (2.5 Gy) doses. The fluorescence measurements were carried out at the X-ray Fluorescence beamline in the Brazilian Synchrotron Light Laboratory. The results showed that the irradiated animals with low doses have significant alterations in blood and cardiac tissue when compared with animals that received high doses of radiation. Taken together the analysis of all the elements, we can observe that the radiation induced oxidative stress may be the leading cause for alteration of the elemental level in the studied samples.

  19. Histological study on acute inflammatory reaction to polyurethane-coated silicone implants in rats Estudo histológico da reação inflamatória aguda ao implante de silicone revestido com poliuretano em ratos

    OpenAIRE

    Paulo Roberto da Silva Mendes; Jorge Bins-Ely; Eduardo Arnaut dos Santos Lima; Zulmar Antonio Accioli de Vasconcellos; Armando José d'Acampora; Rodrigo d' Eça Neves

    2008-01-01

    PURPOSE: Evaluating histologically the silicone peri-implant coated by polyurethane inflammation associated to the use of anti-microbial and bacterial contamination. METHODS: It was used 35 Wistar rats. The animals were divided in seven groups: I - Control; II - implant cavity contamination with10 bacteria/ml; III - implant cavity contamination with 10 bacteria/ml; IV - implant cavity contamination with 10 bacteria/ml; V - identical contamination to group II and implant immersions in anti-mic...

  20. High-precision radiosurgical dose delivery by interlaced microbeam arrays of high-flux low-energy synchrotron X-rays.

    Directory of Open Access Journals (Sweden)

    Raphaël Serduc

    Full Text Available Microbeam Radiation Therapy (MRT is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy. Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 microm wide, spaced 200 microm on-center, 50 to 350 keV in energy range, targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm(3 in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing

  1. Eating high-fat chow increases the sensitivity of rats to quinpirole-induced discriminative stimulus effects and yawning.

    Science.gov (United States)

    Baladi, Michelle G; France, Charles P

    2010-10-01

    Discriminative stimulus effects of direct acting dopamine receptor agonists (e.g. quinpirole) appear to be mediated by D3 receptors in free-feeding rats. Free access to high-fat chow increases sensitivity to quinpirole-induced yawning, and this study examined whether eating high-fat chow increases sensitivity to the discriminative stimulus effects of quinpirole. Five rats discriminated between 0.032 mg/kg quinpirole and vehicle while responding under a continuous reinforcement schedule of stimulus shock termination. When rats had free access to high-fat chow (discrimination training was suspended), the quinpirole discrimination dose-response curve shifted leftward, possibly indicating enhanced sensitivity at D3 receptors. In the same rats, both the ascending (mediated by D3 receptors) and descending (mediated by D2 receptors) limbs of the dose-response curve for quinpirole-induced yawning shifted leftward. When rats had free access to a standard chow (discrimination training was suspended), the quinpirole discrimination and yawning dose-response curves did not change. Together with published data showing that the discriminative stimulus effects of quinpirole in free-feeding rats are mediated by D3 receptors and the insensitivity of this effect of quinpirole to food restriction (shown to increase sensitivity to D2 but not D3-mediated effects), these results suggest that the leftward shift of the discrimination dose-response curve when rats eat high-fat chow is likely because of enhanced sensitivity at D3 receptors. Thus, eating high-fat food enhances drug effects in a manner that might impact clinical effects of drugs or vulnerability to drug abuse.

  2. Eating high fat chow increases the sensitivity of rats to quinpirole-induced discriminative stimulus effects and yawning

    Science.gov (United States)

    Baladi, Michelle G; France, Charles P

    2010-01-01

    Discriminative stimulus effects of directly-acting dopamine receptor agonists (e.g. quinpirole) appear to be mediated by D3 receptors in free-feeding rats. Free access to high fat chow increases sensitivity to quinpirole-induced yawning and the current study examined whether eating high fat chow increases sensitivity to the discriminative stimulus effects of quinpirole. Five rats discriminated between 0.032 mg/kg quinpirole and vehicle while responding under a continuous reinforcement schedule of stimulus shock termination. When rats had free access to high fat chow (discrimination training was suspended), the quinpirole discrimination dose-response curve shifted leftward, possibly indicating enhanced sensitivity at D3 receptors. In the same rats, both the ascending (mediated by D3 receptors) and descending (mediated by D2 receptors) limbs of the dose- response curve for quinpirole-induced yawning shifted leftward. When rats had free access to a standard chow (discrimination training was suspended), the quinpirole discrimination and yawning dose-response curves did not change. Together with published data showing that the discriminative stimulus effects of quinpirole in free- feeding rats are mediated by D3 receptors and the insensitivity of this effect of quinpirole to food restriction (shown to increase sensitivity to D2 but not D3-mediated effects), these results suggest that the leftward shift of the discrimination dose-response curve when rats eat high fat chow is likely due to enhanced sensitivity at D3 receptors. Thus, eating high fat food enhances drug effects in a manner that might impact clinical effects of drugs or vulnerability to drug abuse. PMID:20729718

  3. Guidelines for optimization of planar HDR implants

    International Nuclear Information System (INIS)

    Zwicker, R.D.; Schmidt-Ullrich, R.

    1996-01-01

    Purpose: Conventional low dose rate (LDR) planar Ir-192 implants are typically carried out using at most a few different source strengths. Remote afterloading offers a much higher degree of flexibility with individually programmable dwell times. Dedicated software is available to generate individual dwell times producing isodose surfaces which contour as closely as possible the target volume. The success of these algorithms in enclosing the target volume while sparing normal tissues is dependent on the positioning of the source guides which constrain the dwell points. In this work we provide source placement guidelines for optimal coverage and dose uniformity in planar high dose rate (HDR) implants. The resulting distributions are compared with LDR treatments in terms of dose uniformity and early and late tissue effects. Materials and methods: Computer studies were undertaken to determine source positions and dwell times for optimal dose uniformity in planar HDR implants, and the results were compared to those obtained using corresponding LDR implant geometries. The improvements in the dose distributions achieved with the remote after loader are expected to help offset the increased late tissue effects which can occur when LDR irradiation is replaced with a few large HDR fractions. Equivalent differential volume-dose (DVD) curves for early and late effects were calculated for different numbers of HDR fractions using a linear-quadratic model and compared to the corresponding curves for the LDR regime. Results: Tables of source placement parameters were generated as guidelines for achieving highly homogeneous planar HDR dose distributions. Differential volume-dose data generated inside the target volume provide a quantitative measure of the improvement in real dose homogeneity obtained with remote afterloading. The net result is a shift of the peak in the DVD curve toward lower doses relative to the LDR implant. The equivalent DVD curves for late effects obtained

  4. Perioperative high dose rate (HDR brachytherapy in unresectable locally advanced pancreatic tumors

    Directory of Open Access Journals (Sweden)

    Brygida Białas

    2011-07-01

    Full Text Available Purpose: The aim of the study was to present an original technique of catheter implantation for perioperative HDR-Ir192 brachytherapy in patients after palliative operations of unresectable locally advanced pancreatic tumors and to estimate the influence of perioperative HDR-Ir192 brachytherapy on pain relief in terminal pancreatic cancer patients. Material and methods: Eight patients with pancreatic tumors located in the head of pancreas underwent palliative operations with the use of HDR-Ir192 brachytherapy. All patients qualified for surgery reported pain of high intensity and had received narcotic painkillers prior to operation. During the last phase of the surgery, the Nucletron® catheters were implanted in patients to prepare them for later perioperative brachytherapy. Since the 6th day after surgery HDR brachytherapy was performed. Before each brachytherapy fraction the location of implants were checked using fluoroscopy. A fractional dose was 5 Gy and a total dose was 20 Gy in the area of radiation. A comparative study of two groups of patients (with and without brachytherapy with stage III pancreatic cancer according to the TNM scale was taken in consideration. Results and Conclusions: The authors claim that the modification of catheter implantation using specially designed cannula, facilitates the process of inserting the catheter into the tumor, shortens the time needed for the procedure, and reduces the risk of complications. Mean survival time was 5.7 months. In the group of performed brachytherapy, the mean survival time was 6.7 months, while in the group of no brachytherapy performed – 4.4 months. In the group of brachytherapy, only one patient increased the dose of painkillers in the last month of his life. Remaining patients took constant doses of medicines. Perioperative HDR-Ir192 brachytherapy could be considered as a practical application of adjuvant therapy for pain relief in patients with an advanced pancreatic cancer.

  5. Analysis of metallic traces from the biodegradation of endomedullary AZ31 alloy temporary implants in rat organs after long implantation times.

    Science.gov (United States)

    Bodelón, O G; Iglesias, C; Garrido, J; Clemente, C; Garcia-Alonso, M C; Escudero, M L

    2015-08-04

    AZ31 alloy has been tested as a biodegradable material in the form of endomedullary implants in female Wistar rat femurs. In order to evaluate the accumulation of potentially toxic elements from the biodegradation of the implant, magnesium (Mg), aluminium (Al), zinc (Zn), manganese (Mn) and fluorine (F) levels have been measured in different organs such as kidneys, liver, lungs, spleen and brain. Several factors that may influence accumulation have been taken into account: how long the implant has been in place, whether or not the bone is fractured, and the presence of an MgF2 protective coating on the implant. The main conclusions and the clinical relevance of the study have been that AZ31 endomedullary implants have a degradation rate of about 60% after 13 months, which is fully compatible with fracture consolidation. Neither bone fracture nor an MgF2 coating seems to influence the accumulation of trace elements in the studied organs. Aluminium is the only alloying element in this study that requires special attention. The increase in Al recovered from the sampled organs represents 3.95% of the amount contained in the AZ31 implant. Al accumulates in a statistically significant way in all the organs except the brain. All of this suggests that in long-term tests AZ31 may be a suitable material for osteosynthesis.

  6. Modification of the hydriding of uranium using ion implantation

    International Nuclear Information System (INIS)

    Musket, R.G.; Robinson-Weis, G.; Patterson, R.G.

    1983-01-01

    The hydriding of depleted uranium at 76 Torr hydrogen and 130 0 C has been significantly reduced by implantation of oxygen ions. The high-dose implanted specimens had incubation times for the initiation of the reaction after exposure to hydrogen that exceeded those of the nonimplanted specimens by more than a factor of eight. Furthermore, the nonimplanted specimens consumed enough hydrogen to cause macroscopic flaking of essentially the entire surface in times much less than the incubation time for the high-dose implanted specimens. In contrast, the ion-implanted specimens reacted only at isolated spots with the major fraction of the surface area unaffected by the hydrogen exposure

  7. At WA7

    CERN Multimedia

    1977-01-01

    The CERN-Genoa-Annecy(LAPP)- Niels Bohr Institute, Copenhagen-Oslo-University College,London Collaboration set-up the experiment WA7 to study two-body reactions at large transverse momentum. Here, Michel Yvert, Alberto Santronico, Per Carlson

  8. Investigation of Implantable Multi-Channel Electrode Array in Rat Cerebral Cortex Used for Recording

    Science.gov (United States)

    Taniguchi, Noriyuki; Fukayama, Osamu; Suzuki, Takafumi; Mabuchi, Kunihiko

    There have recently been many studies concerning the control of robot movements using neural signals recorded from the brain (usually called the Brain-Machine interface (BMI)). We fabricated implantable multi-electrode arrays to obtain neural signals from the rat cerebral cortex. As any multi-electrode array should have electrode alignment that minimizes invasion, it is necessary to customize the recording site. We designed three types of 22-channel multi-electrode arrays, i.e., 1) wide, 2) three-layered, and 3) separate. The first extensively covers the cerebral cortex. The second has a length of 2 mm, which can cover the area of the primary motor cortex. The third array has a separate structure, which corresponds to the position of the forelimb and hindlimb areas of the primary motor cortex. These arrays were implanted into the cerebral cortex of a rat. We estimated the walking speed from neural signals using our fabricated three-layered array to investigate its feasibility for BMI research. The neural signal of the rat and its walking speed were simultaneously recorded. The results revealed that evaluation using either the anterior electrode group or posterior group provided accurate estimates. However, two electrode groups around the center yielded poor estimates although it was possible to record neural signals.

  9. Assessment of I-125 seed implant accuracy when using the live-planning technique for low dose rate prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Moorrees Joshua

    2012-11-01

    Full Text Available Abstract Background Low risk prostate cancers are commonly treated with low dose rate (LDR brachytherapy involving I-125 seeds. The implementation of a ‘live-planning’ technique at the Royal Adelaide Hospital (RAH in 2007 enabled the completion of the whole procedure (i.e. scanning, planning and implant in one sitting. ‘Live-planning’ has the advantage of a more reliable delivery of the planned treatment compared to the ‘traditional pre-plan’ technique (where patient is scanned and planned in the weeks prior to implant. During live planning, the actual implanted needle positions are updated real-time on the treatment planning system and the dosimetry is automatically recalculated. The aim of this investigation was to assess the differences and clinical relevance between the planned dosimetry and the updated real-time implant dosimetry. Methods A number of 162 patients were included in this dosimetric study. A paired t-test was performed on the D90, V100, V150 and V200 target parameters and the differences between the planned and implanted dose distributions were analysed. Similarly, dosimetric differences for the organs at risk (OAR were also evaluated. Results Small differences between the primary dosimetric parameters for the target were found. Still, the incidence of hotspots was increased with approximately 20% for V200. Statistically significant increases were observed in the doses delivered to the OAR between the planned and implanted data; however, these increases were consistently below 3% thus probably without clinical consequences. Conclusions The current study assessed the accuracy of prostate implants with I-125 seeds when compared to initial plans. The results confirmed the precision of the implant technique which RAH has in place. Nevertheless, geographical misses, anatomical restrictions and needle displacements during implant can have repercussions for centres without live-planning option if dosimetric changes are not

  10. Low-dose rhBMP2/7 heterodimer to reconstruct peri-implant bone defects: a micro-CT evaluation

    NARCIS (Netherlands)

    Wang, J.; Zheng, Y.; Zhao, J.; Liu, T.; Gao, L.; Gu, Z.; Wu, G.

    2012-01-01

    Objectives To delineate the dynamic micro-architectures of bone induced by low-dose bone morphogenetic protein (BMP)-2/7 heterodimer in peri-implant bone defects compared to BMP2 and BMP7 homodimer. Material and Methods Peri-implant bone defects (8 mm in diameter, 4 mm in depth) were created

  11. Low preveance ion source bridges low and high intensities in ion implantation

    International Nuclear Information System (INIS)

    Orr, F.D.; Mayhall, D.

    1976-01-01

    The Low Perveance Ion Source developed by Accelerators, Inc. offers the Semiconductor Industry the advantage of processing medium to high intensity implants on a system which will also implant 200 to 300 wafers an hour at MOS doses. Stable source beam currents can be varied over three orders of magnitude by variation of a single source parameter. This source uses a new computer designed Low Perveance extraction optics which is completely new to the Ion Implantation Industry. Test data and calculations are shown which define the versatility of this system. Scanned currents from 1 microamp to 400 microamps allow for a variety of production processing. Beam characteristics feature low energy spread (less than 10 eV) and low divergence (less than 3 degrees). Beam control optics consist of a double focusing analyzing magnet and two triplet quadrupoles. The source may be fitted with an oven for feeding of solid materials and analyzed beam currents in the milliamp range for development purposes. The batch processing, hybrid scanning end station is most applicable for high current beams as well as high volume batch processings of MOS Implants. Results of development work toward increased currents using both solid and gas feed material with the Low Perveance source are presented. System improvements including Accel-Decel and a third extraction element are discussed

  12. Ion implantation in semiconductors

    International Nuclear Information System (INIS)

    Gusev, V.; Gusevova, M.

    1980-01-01

    The historical development is described of the method of ion implantation, the physical research of the method, its technological solution and practical uses. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material, ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions. (M.S.)

  13. Ion implantation in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, V; Gusevova, M

    1980-06-01

    The historical development of the method of ion implantation, the physical research of the method, its technological solution and practical uses is described. The method is universally applicable, allows the implantation of arbitrary atoms to an arbitrary material and ensures high purity of the doping element. It is linked with sample processing at low temperatures. In implantation it is possible to independently change the dose and energy of the ions thereby affecting the spatial distribution of the ions.

  14. A Wireless and Batteryless Microsystem with Implantable Grid Electrode/3-Dimensional Probe Array for ECoG and Extracellular Neural Recording in Rats

    Directory of Open Access Journals (Sweden)

    Chih-Wei Chang

    2013-04-01

    Full Text Available This paper presents the design and implementation of an integrated wireless microsystem platform that provides the possibility to support versatile implantable neural sensing devices in free laboratory rats. Inductive coupled coils with low dropout regulator design allows true long-term recording without limitation of battery capacity. A 16-channel analog front end chip located on the headstage is designed for high channel account neural signal conditioning with low current consumption and noise. Two types of implantable electrodes including grid electrode and 3D probe array are also presented for brain surface recording and 3D biopotential acquisition in the implanted target volume of tissue. The overall system consumes less than 20 mA with small form factor, 3.9 × 3.9 cm2 mainboard and 1.8 × 3.4 cm2 headstage, is packaged into a backpack for rats. Practical in vivo recordings including auditory response, brain resection tissue and PZT-induced seizures recording demonstrate the correct function of the proposed microsystem. Presented achievements addressed the aforementioned properties by combining MEMS neural sensors, low-power circuit designs and commercial chips into system-level integration.

  15. Effect of kefir and low-dose aspirin on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet.

    Science.gov (United States)

    Kanbak, Güngör; Uzuner, Kubilay; Kuşat Ol, Kevser; Oğlakçı, Ayşegül; Kartkaya, Kazım; Şentürk, Hakan

    2014-01-01

    Abstract We aim to study the effect of low-dose aspirin and kefir on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet. Forty adult male Sprague-Dawley rats were divided into five groups: control, high-salt (HS) (8.0% NaCl), HS+aspirin (10 mg/kg), HS+kefir (10.0%w/v), HS+aspirin +kefir. We measured sistolic blood pressure (SBP), mean arterial pressure (MAP), diastolic pressure, pulse pressure in the rats. Cathepsin B, L, DNA fragmentation and caspase-3 activities were determined from rat kidney tissues and rats clearance of creatinine calculated. Although HS diet increased significantly SBP, MAP, diastolic pressure, pulse pressure parameters compared the control values. They were not as high as accepted hypertension levels. When compared to HS groups, kefir groups significantly decrease Cathepsin B and DNA fragmentation levels. Caspase levels were elevated slightly in other groups according to control group. While, we also found that creatinine clearance was higher in HS+kefir and HS+low-dose aspirin than HS group. Thus, using low-dose aspirin had been approximately decreased of renal function damage. Kefir decreased renal function damage playing as Angiotensin-converting enzyme inhibitor. But, low-dose aspirin together with kefir worsened rat renal function damage. Cathepsin B might play role both apoptosis and prorenin-processing enzyme. But not caspase pathway may be involved in the present HS diet induced apoptosis. In conclusion, kefir and low-dose aspirin used independently protect renal function and renal damage induced by HS diet in rats.

  16. MCHANGO WA MWALIMU J.K. NYERERE KATIKA TAFSIRI NA ...

    African Journals Online (AJOL)

    Kwa kuzingatia tafsiri mbili za J.K. Nyerere, Julius Kaizer (1963) na Mabepari wa Venus (1969), makala inaeleza: (i) kwa nini Mwalimu Nyerere alitafsiri maandishi ya Shakespeare, (ii) ufanisi wa tafsiri zake, na (iii) mchango wa tafsiri hizo. Makala inaonyesha kuwa tafsiri hizo zinazingatia mbinu za kisemantiki zaidi kuliko ...

  17. SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

    Energy Technology Data Exchange (ETDEWEB)

    Damilakis, J; Stratakis, J; Solomou, G [University of Crete, Heraklion (Greece)

    2014-06-01

    Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

  18. SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

    International Nuclear Information System (INIS)

    Damilakis, J; Stratakis, J; Solomou, G

    2014-01-01

    Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

  19. Immune reactivity after high-dose irradiation

    International Nuclear Information System (INIS)

    Gassmann, W.; Wottge, H.U.; von Kolzynski, M.; Mueller-Ruchholtz, W.

    1986-01-01

    Immune reactivity after total-body irradiation was investigated in rats using skin graft rejection as the indicator system. After sublethal irradiation with 10.5 Gy (approximately 50% lethality/6 weeks) the rejection of major histocompatibility complex allogeneic skin grafts was delayed significantly compared with nonirradiated control animals (28 versus 6.5 days). In contrast, skin grafts were rejected after 7.5 days in sublethally irradiated animals and 7 days in lethally irradiated animals if additional skin donor type alloantigens--namely, irradiated bone marrow cells--were given i.v. either simultaneously or with a delay of not more than 24 hr after the above conditioning regimen. These reactions were alloantigen-specific. They were observed in six different strain combinations with varying donors and recipients. Starting on day 2 after irradiation, i.v. injection of bone marrow gradually lost its effectivity and skin grafts were no longer rejected with uniform rapidity; skin donor marrow given on days 4 or 8 did not accelerate skin graft rejection at all. These data show that for approximately 1-2 days after high-dose total-body irradiation rats are still capable of starting a vigorous immune reaction against i.v.-injected alloantigens. The phenomenon of impaired rejection of skin grafted immediately after high-dose irradiation appears to result from the poor accessibility of skin graft alloantigens during the early postirradiation phase when vascularization of the grafted skin is insufficient

  20. Swim Training Improves HOMA-IR in Type 2 Diabetes Induced by High Fat Diet and Low Dose of Streptozotocin in Male Rats.

    Science.gov (United States)

    Ghiasi, Rafigheh; Ghadiri Soufi, Farhad; Somi, Mohammad Hossein; Mohaddes, Gisou; Mirzaie Bavil, Fariba; Naderi, Roya; Alipour, Mohammad Reza

    2015-09-01

    Insulin resistance plays a key role in the onset and development of type 2 diabetes mellitus (T2DM) and its complications. In this study, we evaluated the effect of swim training on insulin resistance in diabetic rats. Forty male Wistar rats were randomly divided into four groups (n=10): sedentary control (Con), sedentary diabetic (Dia), swim trained control (Exe) and swim trained diabetic (Dia+Exe) rats. Diabetes was induced by high fat diet (HFD) and a low dose of streptozotocin (35 mg/kg, i.p). In trained groups, one week after the induction of diabetes, animals were subjected to swimming (60 min/5 days a week) for 10 weeks. At the end of training, fasting blood sugar (FBS), oral glucose tolerance test (OGTT), fasting/basal insulin, glycosylated hemoglobin (HbA1c) levels, insulin resistance index, homeostasis model assessment method (HOMA-IR), triglycerides (TG,) total cholesterol (TCh), and high density lipoprotein (HDL) levels in blood were measured. Swimming significantly improved OGTT (PHOMA-IR (P<0.01). Swim training also significantly decreased FBS (p<0.01), fasting/basal insulin (P<0.01), HbA1C (p<0.01), TG (P<0.05), and TCh (P<0.05) levels. It also significantly increased HDL (p<0.05) level. Our findings indicate that swim training improved glycemic control and insulin sensitivity in type 2 diabetes caused by high fat diet in male rats.

  1. Silver oxide-containing hydroxyapatite coating supports osteoblast function and enhances implant anchorage strength in rat femur.

    Science.gov (United States)

    Eto, Shuichi; Miyamoto, Hiroshi; Shobuike, Takeo; Noda, Iwao; Akiyama, Takayuki; Tsukamoto, Masatsugu; Ueno, Masaya; Someya, Shinsuke; Kawano, Shunsuke; Sonohata, Motoki; Mawatari, Masaaki

    2015-09-01

    Antibacterial silver with hydroxyapatite (Ag-HA) is a promising coating material for imparting antibacterial properties to implants. We previously reported that 3% (w/w) silver with HA (3% Ag-HA) has both antibacterial activity and osteoconductivity. In this study, we investigated the effects of Ag-HA on the in vitro osteoblast function and the in vivo anchorage strength and osteoconductivity of implants. Production of the osteoblast marker alkaline phosphatase, but not cytotoxicity, was observed in cells of the osteoblast cell line MC3T3-E1 cultured on the 3% Ag-HA-coated surface. These results were similar to those observed with silver-free HA coating. In contrast, a significant high level of cytotoxicity was observed when the cells were cultured on a 50% Ag-HA-coated surface. The anchorage strength of implants inserted into the femur of Sprague-Dawley (SD) rats was enhanced by coating the implants with 3% Ag-HA. On the 3% Ag-HA-coated surface, both metaphyseal and diaphyseal areas were largely covered with new bone and had adequate osteoconductivity. These results suggest that 3% Ag-HA, like conventional HA, promotes osteogenesis by supporting osteoblast viability and function and thereby contributes to sufficient anchorage strength of implants. Application of 3% Ag-HA, which combines the osteoconductivity of HA and the antibacterial activity of silver, to prosthetic joints will help prevent postoperative infections. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. Developing A Directional High-Dose Rate (d-HDR) Brachytherapy Source

    Science.gov (United States)

    Heredia, Athena Yvonne

    Conventional sources used in brachytherapy provide nearly isotropic or radially symmetric dose distributions. Optimizations of dose distributions have been limited to varied dwell times at specified locations within a given treatment volume, or manipulations in source position for seed implantation techniques. In years past, intensity modulated brachytherapy (IMBT) has been used to reduce the amount of radiation to surrounding sensitive structures in select intracavitary cases by adding space or partial shields. Previous work done by Lin et al., at the University of Wisconsin-Madison, has shown potential improvements in conformality for brachytherapy treatments using a directionally shielded low dose rate (LDR) source for treatments in breast and prostate. Directional brachytherapy sources irradiate approximately half of the radial angles around the source, and adequately shield a quarter of the radial angles on the opposite side, with sharp gradient zones between the treated half and shielded quarter. With internally shielded sources, the radiation can be preferentially emitted in such a way as to reduce toxicities in surrounding critical organs. The objective of this work is to present findings obtained in the development of a new directional high dose rate (d-HDR) source. To this goal, 103Pd (Z = 46) is reintroduced as a potential radionuclide for use in HDR brachytherapy. 103Pd has a low average photon energy (21 keV) and relatively short half -life (17 days), which is why it has historically been used in low dose rate applications and implantation techniques. Pd-103 has a carrier-free specific activity of 75000 Ci/g. Using cyclotron produced 103Pd, near carrier-free specific activities can be achieved, providing suitability for high dose rate applications. The evolution of the d-HDR source using Monte Carlo simulations is presented, along with dosimetric parameters used to fully characterize the source. In addition, a discussion on how to obtain elemental

  3. Technical aspects of the integration of three-dimensional treatment planning dose parameters (GEC-ESTRO Working Group) into pre-implant planning for LDR gynecological interstitial brachytherapy.

    Science.gov (United States)

    Chi, A; Gao, M; Nguyen, N P; Albuquerque, K

    2009-06-01

    This study investigates the technical feasibility of pre-implant image-based treatment planning for LDR GYN interstitial brachytherapy(IB) based on the GEC-ESTRO guidelines. Initially, a virtual plan is generated based on the prescription dose and GEC-ESTRO defined OAR dose constraints with a pre-implant CT. After the actual implant, a regular diagnostic CT was obtained and fused with our pre-implant scan/initial treatment plan in our planning software. The Flexi-needle position changes, and treatment plan modifications were made if needed. Dose values were normalized to equivalent doses in 2 Gy fractions (LQED 2 Gy) derived from the linear-quadratic model with alpha/beta of 3 for late responding tissues and alpha/beta of 10 for early responding tissues. D(90) to the CTV, which was gross tumor (GTV) at the time of brachytherapy with a margin to count for microscopic disease, was 84.7 +/- 4.9% of the prescribed dose. The OAR doses were evaluated by D(2cc) (EBRT+IB). Mean D(2cc) values (LQED(2Gy)) for the rectum, bladder, sigmoid, and small bowel were the following: 63.7 +/- 8.4 Gy, 61.2 +/- 6.9 Gy, 48.0 +/- 3.5 Gy, and 49.9 +/- 4.2 Gy. This study confirms the feasibility of applying the GEC-ESTRO recommended dose parameters in pre-implant CT-based treatment planning in GYN IB. In the process, this pre-implant technique also demonstrates a good approximation of the target volume dose coverage, and doses to the OARs.

  4. Low-dose rhBMP2/7 heterodimer to reconstruct peri-implant bone defects: a micro-CT evaluation.

    Science.gov (United States)

    Wang, Jingxiao; Zheng, Yuanna; Zhao, Juan; Liu, Tie; Gao, Lixia; Gu, Zhiyuan; Wu, Gang

    2012-01-01

    To delineate the dynamic micro-architectures of bone induced by low-dose bone morphogenetic protein (BMP)-2/7 heterodimer in peri-implant bone defects compared to BMP2 and BMP7 homodimer. Peri-implant bone defects (8 mm in diameter, 4 mm in depth) were created surrounding SLA-treated titanium implants (3.1 mm in diameter, 10 mm in length) in minipig's calvaria. We administrated collagen sponges with adsorbed low-dose (30 ng/mm(3) ) BMP2/7 to treat the defects using BMP2, BMP7 or no BMP as controls.2, 3 and 6 weeks after implantation, we adopted micro-computer tomography to evaluate the micro-architectures of new bone using the following parameters: relative bone volume (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), connectivity density, and structure mode index (SMI). Bone implant contact (BIC) was also revealed histologically. Consistent with 2 and 3 weeks, after 6 weeks post-operation, BMP2/7 resulted in significantly higher BV/TV (63.033 ± 2.055%) and significantly lower SMI (-4.405 ± 0.500) than BMP2 (BV/TV: 43.133 ± 2.001%; SMI: -0.086 ± 0.041) and BMP7 (BV/TV: 41.467 ± 1.850%; SMI: -0.044 ± 0.016) respectively. Significant differences were also found in Tb.N, Tb.Th and Tb.Sp at all time points. At 2 weeks, BMP2/7 resulted in significantly higher BIC than the controls. Low-dose BMP2/7 heterodimer facilitated more rapid bone regeneration in better quality in peri-implant bone defects than BMP2 and BMP7 homodimers. © 2011 John Wiley & Sons A/S.

  5. Dose-Related Effects of Acetylsalicylic acid (ASA) on Gamma Radiation-Induced Teratogenicity in Pregnant Albino Rats

    International Nuclear Information System (INIS)

    Ibrahim, M.F.

    2013-01-01

    Reviews of acetylsalicylic acid (ASA), a widely used nonsteroidal anti- inflammatory drug, has consistently suggested a possible association between prenatal ASA ingestion and adverse effects in the pregnant mothers and their developing fetuses. The objective of the current study was to comprehensively define the effect of relatively low and high doses of ASA (25 mg/kg body wt. and 200 mg/kg body wt. respectively) on gestating rats and their possible impact on the irradiated ones. Therefore 36 pregnant rats were randomly divided into 6 equal groups. Three rat groups were daily orally gavaged from the 7th to the 18th gestational days with: distilled water (Group 1), 25 mg/kg body wt. ASA (Group 2) and 200 mg/kg body wt. ASA (Group 3). The other three groups similarly received the same previous treatments besides 2 Gy whole body gamma irradiation of each, to serve as: Group 4 (distilled water + irradiation), Group 5 (25 mg/kg body wt. ASA + irradiation) and Group 6 (200 mg/kg body wt. ASA + irradiation). All rat groups were sacrificed on the 20th day of pregnancy and the uterine contents were examined. The lower ASA dose (25 mg/kg body wt.) treated group (Group 2) displayed healthy mothers and fetuses whereas that of the higher dose (200 mg/kg body wt.) (Group 3) despite not showing significant maternal or fetal mortalities, yet the intrauterine contents presented fetal developmental disorders including stunted growth and resorption together with some head and limb anomalies including plagiocephaly, marked acampsia and acrocontracture. Meanwhile, results have unexpectedly shown a radioprotective role of the lower ASA dose (25 mg/kg. body wt.) (Group 5) to pregnant rats and their fetuses as inspected by its efficacy in retrieving the radiation induced maternal weight loss together with its noticeable ameliorating effects on the intrauterine lethality of the affected fetuses and their externally detected abnormalities in addition toits effectiveness in retaining some

  6. Neonatal Handling Produces Sex Hormone-Dependent Resilience to Stress-Induced Muscle Hyperalgesia in Rats.

    Science.gov (United States)

    Alvarez, Pedro; Green, Paul G; Levine, Jon D

    2018-06-01

    Neonatal handling (NH) of male rat pups strongly attenuates stress response and stress-induced persistent muscle hyperalgesia in adults. Because female sex is a well established risk factor for stress-induced chronic muscle pain, we explored whether NH provides resilience to stress-induced hyperalgesia in adult female rats. Rat pups underwent NH, or standard (control) care. Muscle mechanical nociceptive threshold was assessed before and after water avoidance (WA) stress, when they were adults. In contrast to male rats, NH produced only a modest protection against WA stress-induced muscle hyperalgesia in female rats. Gonadectomy completely abolished NH-induced resilience in male rats but produced only a small increase in this protective effect in female rats. The administration of the antiestrogen drug fulvestrant, in addition to gonadectomy, did not enhance the protective effect of NH in female rats. Finally, knockdown of the androgen receptor by intrathecal antisense treatment attenuated the protective effect of NH in intact male rats. Together, these data indicate that androgens play a key role in NH-induced resilience to WA stress-induced muscle hyperalgesia. NH induces androgen-dependent resilience to stress-induced muscle pain. Therefore, androgens may contribute to sex differences observed in chronic musculoskeletal pain and its enhancement by stress. Copyright © 2018 The American Pain Society. Published by Elsevier Inc. All rights reserved.

  7. Immunological Response to Biodegradable Magnesium Implants

    Science.gov (United States)

    Pichler, Karin; Fischerauer, Stefan; Ferlic, Peter; Martinelli, Elisabeth; Brezinsek, Hans-Peter; Uggowitzer, Peter J.; Löffler, Jörg F.; Weinberg, Annelie-Martina

    2014-04-01

    The use of biodegradable magnesium implants in pediatric trauma surgery would render surgical interventions for implant removal after tissue healing unnecessary, thereby preventing stress to the children and reducing therapy costs. In this study, we report on the immunological response to biodegradable magnesium implants—as an important aspect in evaluating biocompatibility—tested in a growing rat model. The focus of this study was to investigate the response of the innate immune system to either fast or slow degrading magnesium pins, which were implanted into the femoral bones of 5-week-old rats. The main alloying element of the fast-degrading alloy (ZX50) was Zn, while it was Y in the slow-degrading implant (WZ21). Our results demonstrate that degrading magnesium implants beneficially influence the immune system, especially in the first postoperative weeks but also during tissue healing and early bone remodeling. However, rodents with WZ21 pins showed a slightly decreased phagocytic ability during bone remodeling when the degradation rate reached its maximum. This may be due to the high release rate of the rare earth-element yttrium, which is potentially toxic. From our results we conclude that magnesium implants have a beneficial effect on the innate immune system but that there are some concerns regarding the use of yttrium-alloyed magnesium implants, especially in pediatric patients.

  8. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  9. Survival of rats bearing advanced intracerebral F 98 tumors after glutathione depletion and microbeam radiation therapy: conclusions from a pilot project.

    Science.gov (United States)

    Schültke, E; Bräuer-Krisch, E; Blattmann, H; Requardt, H; Laissue, J A; Hildebrandt, G

    2018-05-10

    Resistance to radiotherapy is frequently encountered in patients with glioblastoma multiforme. It is caused at least partially by the high glutathione content in the tumour tissue. Therefore, the administration of the glutathione synthesis inhibitor Buthionine-SR-Sulfoximine (BSO) should increase survival time. BSO was tested in combination with an experimental synchrotron-based treatment, microbeam radiation therapy (MRT), characterized by spatially and periodically alternating microscopic dose distribution. One hundred thousand F98 glioma cells were injected into the right cerebral hemisphere of adult male Fischer rats to generate an orthotopic small animal model of a highly malignant brain tumour in a very advanced stage. Therapy was scheduled for day 13 after tumour cell implantation. At this time, 12.5% of the animals had already died from their disease. The surviving 24 tumour-bearing animals were randomly distributed in three experimental groups: subjected to MRT alone (Group A), to MRT plus BSO (Group B) and tumour-bearing untreated controls (Group C). Thus, half of the irradiated animals received an injection of 100 μM BSO into the tumour two hours before radiotherapy. Additional tumour-free animals, mirroring the treatment of the tumour-bearing animals, were included in the experiment. MRT was administered in bi-directional mode with arrays of quasi-parallel beams crossing at the tumour location. The width of the microbeams was ≈28 μm with a center-to-center distance of ≈400 μm, a peak dose of 350 Gy, and a valley dose of 9 Gy in the normal tissue and 18 Gy at the tumour location; thus, the peak to valley dose ratio (PVDR) was 31. After tumour-cell implantation, otherwise untreated rats had a mean survival time of 15 days. Twenty days after implantation, 62.5% of the animals receiving MRT alone (group A) and 75% of the rats given MRT + BSO (group B) were still alive. Thirty days after implantation, survival was 12.5% in Group A and 62

  10. Transient alterations in neurotransmitter activity in the caudate nucleus of rat brain after a high dose of ionizing radiation

    International Nuclear Information System (INIS)

    Hunt, W.A.; Dalton, T.K.; Darden, J.H.

    1979-01-01

    A single 10,000-rad dose of high-energy electrons induced an increase in dopaminergic and cholinergic activity in the caudate nucleus of the rat brain as assessed by K + -stimulated dopamine release in vitro and high-affinity choline uptake. These alterations occur during early transient incapacitation (ETI) and dissipate as the animal recovers behaviorally, in about 30 min after irradiation. Although the responses observed resemble those that result from blockade of dopamine receptors, no radiation-induced changes were found in dopamine-sensitive adenylate cyclase activity and [ 3 H]haloperidol binding, two indices of dopaminergic receptor function. The data suggest that changes in dopaminergic and cholinergic activity are associated with the development of ETI and may play a role in the behavioral decrement observed under this condition

  11. The aesthetic interpretation on Wooden Drum Dancing of Wa people

    Directory of Open Access Journals (Sweden)

    Youfeng Wang

    2017-02-01

    Full Text Available The Wa nationality, a typical ethnic group in Yunnan province, is an ancient one lives across Yunnan. The main residences of it are border area beside northern Yunnan and the Wa States in Burma. Among all the Wa dances, Wooden Drum Dancing leads a vital position, and it is also a symbolic dancing in the culture of Wa people. The feature of Wooden Drum Dancing is that every action expending by the beats of wooden drum, namely, first the wooden drum, then the Wooden Drum Dancing. Dancing is an important content in the life of Wa people, and the aesthetics of life comes from dancing, so they present their value on worship by the form of dancing. This article is going to interpret the aesthetic standard on Wa people’s Wooden Drum Dancing by the view of aesthetics, and come into a conclude that the inspiration of such dancing came from practice and their worship to nature and ancestor. The Wooden Drum Dancing displays totally the tough air and solidarity of Wa people, which also presents the fair society of them. The Wooden Drum Dancing is an enriched art that Wa People took from particle life, so dancing of Wa is often classified into the aesthetic area of plain. The information of people’s living situation displayed by Wa dancing also conveys their rich emotions. The sense of beauty within Wooden Drum Dancing will give others a solemn feeling. The formal beauty is displayed by the rhythm of upper part of body, and the power beauty is displayed by the rhythm of the lower part of body.

  12. Embryotoxicity of benzalkonium chloride in vaginally treated rats.

    Science.gov (United States)

    Buttar, H S

    1985-12-01

    The effects of the spermicide benzalkonium chloride (BKC) were studied on the conceptus of rat. Single doses (0, 25, 50, 100 or 200 mg kg-1) of aqueous solutions of BKC were administered intravaginally (1 ml kg-1) on gestational day 1. The vulval metallic clips, used to prevent leakage of the solution, were removed 24 h post-treatment. Fetuses were obtained and examined for malformations on day 21 of gestation. slight to copious amounts of vaginal discharge and vaginitis were noticed in rats treated with the two largest doses of BKC. A dose-related increase in resorptions and fetal death, reduction in litter size and weight were observed in BKC-treated dams. The conceptus loss seemed to occur both before and after implantation. BKC did not cause any discernible visceral malformations, although minor sternal defects occurred in fetuses exposed to 100 and 200 mg kg-1 of the spermicide. These results suggest that single vaginal application of BKC is embryo- and fetocidal in the rat at a dose about 143 times higher than that recommended for controlling conception in women.

  13. The effects of thyroxine on metabolism and water balance in a desert-dwelling rodent, Merriam's kangaroo rat (Dipodomys merriami).

    Science.gov (United States)

    Banta, Marilyn R; Holcombe, Dale W

    2002-01-01

    Desert-dwelling mammals such as Merriam's kangaroo rat (Dipodomys merriani) need to conserve both energy and water to survive desert conditions characterized by aridity and low productivity. The thyroid hormone thyroxine increases both basal metabolic rate and urinary water loss in mammals. Increases in basal metabolism and urinary water loss are likely to be detrimental to D. merriami, therefore the regulation of this hormone may be important. To examine the effects of thyroxine in this species, we implanted adult kangaroo rats with pellets designed to release specific doses of thyroxine at a constant rate for 90 days or a placebo pellet. We measured plasma thyroxine concentration, basal metabolic rate, food consumption, urine concentration and water loss in all implanted animals. Thyroxine implants significantly increased both plasma thyroxine and basal metabolic rate in a relatively dose-dependent manner. In response to thyroxine. kangaroo rats increased food consumption only slightly, but this small increase was sufficient to compensate for their elevated metabolic rates. Neither urine concentration nor water loss varied among treatment groups. Thyroxine increased energy expenditure but not water loss in this species.

  14. High Doses of Caffeine during the Peripubertal Period in the Rat Impair the Growth and Function of the Testis

    Directory of Open Access Journals (Sweden)

    Minji Park

    2015-01-01

    Full Text Available Prenatal caffeine exposure adversely affects the development of the reproductive organs of male rat offspring. Thus, it is conceivable that peripubertal caffeine exposure would also influence physiologic gonadal changes and function during this critical period for sexual maturation. This study investigated the impact of high doses of caffeine on the testes of prepubertal male rats. A total of 45 immature male rats were divided randomly into three groups: a control group and 2 groups fed 120 and 180 mg/kg/day of caffeine, respectively, via the stomach for 4 weeks. Caffeine caused a significant decrease in body weight gain, accompanied by proportional decreases in lean body mass and body fat. The caffeine-fed animals had smaller and lighter testes than those of the control that were accompanied by negative influences on the histologic parameters of the testes. In addition, stimulated-testosterone ex vivo production was reduced in Leydig cells retrieved from the caffeine-fed animals. Our results demonstrate that peripubertal caffeine consumption can interfere with the maturation and function of the testis, possibly by interrupting endogenous testosterone secretion and reducing the sensitivity of Leydig cells to gonadotrophic stimulation. In addition, we confirmed that pubertal administration of caffeine reduced testis growth and altered testis histomorphology.

  15. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Froehlich, Georgina; Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor

    2010-01-01

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D min ) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D r ) and urethra (D u ), dose to volume of 2 cm 3 of the rectum (D 2ccm ), and 0.1 cm 3 and 1% of the urethra (D 0.1ccm and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V p ) was 27.1 cm 3 . The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D min was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D 2ccm = 49% for the rectum, D 0.1ccm = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D r , D 2ccm ) = 0.69, R(D u , D 0.1ccm ) = 0.64, R(D u , D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric

  16. Dosimetric evaluation of high-dose-rate interstitial brachytherapy boost treatments for localized prostate cancer.

    Science.gov (United States)

    Fröhlich, Georgina; Agoston, Péter; Lövey, József; Somogyi, András; Fodor, János; Polgár, Csaba; Major, Tibor

    2010-07-01

    To quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D(min)) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D(r)) and urethra (D(u)), dose to volume of 2 cm(3) of the rectum (D(2ccm)), and 0.1 cm(3) and 1% of the urethra (D(0.1ccm) and D1) were determined. Nonparametric correlation analysis was performed between these parameters. The median number of needles was 16, the mean prostate volume (V(p)) was 27.1 cm(3). The mean V90, V100, V150, and V200 were 99%, 97%, 39%, and 13%, respectively. The mean D90 was 109%, and the D(min) was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D(2ccm) = 49% for the rectum, D(0.1ccm) = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D(r),D(2ccm)) = 0.69, R(D(u),D0.(1ccm)) = 0.64, R(D(u),D1) = 0.23. US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose-volume parameters. For urethra dose characterization, the use of D1 volumetric parameter is recommended.

  17. Regulation of operant oral ethanol self-administration: a dose-response curve study in rats.

    Science.gov (United States)

    Carnicella, Sebastien; Yowell, Quinn V; Ron, Dorit

    2011-01-01

    Oral ethanol self-administration procedures in rats are useful preclinical tools for the evaluation of potential new pharmacotherapies as well as for the investigation into the etiology of alcohol abuse disorders and addiction. Determination of the effects of a potential treatment on a full ethanol dose-response curve should be essential to predict its clinical efficacy. Unfortunately, this approach has not been fully explored because of the aversive taste reaction to moderate to high doses of ethanol, which may interfere with consumption. In this study, we set out to determine whether a meaningful dose-response curve for oral ethanol self-administration can be obtained in rats. Long-Evans rats were trained to self-administer a 20% ethanol solution in an operant procedure following a history of excessive voluntary ethanol intake. After stabilization of ethanol self-administration, the concentration of the solution was varied from 2.5 to 60% (v/v), and operant and drinking behaviors, as well as blood ethanol concentration (BEC), were evaluated following the self-administration of a 20, 40, and 60% ethanol solution. Varying the concentration of ethanol from 2.5 to 60% after the development of excessive ethanol consumption led to a typical inverted U-shaped dose-response curve. Importantly, rats adapted their level and pattern of responding to changes in ethanol concentration to obtain a constant level of intake and BEC, suggesting that their operant behavior is mainly driven by the motivation to obtain a specific pharmacological effect of ethanol. This procedure can be a useful and straightforward tool for the evaluation of the effects of new potential pharmacotherapies for the treatment of alcohol abuse disorders. Copyright © 2010 by the Research Society on Alcoholism.

  18. Investigation of the atomic interface structure of mesotaxial Si/CoSi2(100) layers formed by high-dose implantation

    International Nuclear Information System (INIS)

    Bulle-Lieuwma, C.W.T.; Jong, A.F. de; Vandenhoudt, D.E.W.

    1991-01-01

    Aligned mesotaxial films of CoSi 2 in monocrystalline (100) oriented Si substrates have been formed by high-dose ion implantation of Co, followed by a high temperature treatment. The atomic structures of both the lower and upper Si/CoSi 2 (100) interfaces of the buried CoSi 2 layer have been investigated by high-resolution electron microscopy (HREM) combined with image simulations. A domain-like structure is observed consisting of areas with different interfaces. In order to derive the atomic configuration, image simulations of different proposed models are presented. By comparing simulated images and HREM images, two different atomic structure models for the Si/CoSi 2 (100) interface have been found. In the first model the interfacial Co atoms are six-fold coordinated and the tetrahedral coordination and bond lengths of silicon atoms are everywhere maintained. In the second model we found evidence for a 2 x 1 interface reconstruction, involving a difference in composition. The interfacial Co atoms are seven-fold coordinated. It is shown that the boundaries between the domains are associated with interfacial dislocations of edge-type with Burgers vectors b a/4 inclined and b = a/2 parallel to the interfacial plane. (author)

  19. Embryonic mortality and intrauterine growth retardation (IUGR) associated with placental alterations in pregnant rats treated with methyl methanesulfonate (MMS) at the peri-implantation stage.

    Science.gov (United States)

    Yokoi, Ryohei; Hayashi, Morimichi; Tamura, Toru; Kobayashi, Kazuo; Kuroda, Junji; Kusama, Hiroshi; Kagami, Hiroshi; Ono, Tamao

    2008-12-01

    Embryonic mortality and intrauterine growth retardation (IUGR) are induced by exposure of rodents to xenobiotic agents during the pregastrulation period of development. We examined the time course of the effects of methyl methanesulfonate (MMS), an alkylating agent, on conceptus development in order to clarify the relative roles of the embryo and the placenta in their induction. Pregnant rats were treated orally with a single dose of MMS (200 mg/kg) in the morning of gestation day (GD) 6 (peri-implantation stage). Embryonic mortality was increased on GD12 and thereafter by MMS treatment, with newly dead embryos showing placental hypoplasia at GD12. Embryo or fetal weight was also smaller for MMS-treated dams than for control dams from GD14 to GD20. The labyrinth zone and junctional zone (JZ) of the placenta were thinner in MMS-treated rats from GD12 to GD17 and from GD12 to GD20 (except for GD17), respectively. Furthermore, MMS-treated dams showed a smaller number of glycogen cells in the JZ on GD14. In contrast, the placental glycogen concentration was higher and the expression of glucose transporter 1 in the JZ remained at GD20. These results indicate that exposure of pregnant rats to MMS at the peri-implantation stage of embryogenesis affects placental development and growth. The placental impairment induced by MMS was likely responsible for the embryonic death observed 6 days after exposure of dams to this agent as well as for the IUGR of surviving embryos or fetuses throughout the gestation period.

  20. Evaluation of the effect of implanted depleted uranium on male reproductive success, sperm concentration, and sperm velocity

    International Nuclear Information System (INIS)

    Arfsten, Darryl P.; Schaeffer, David J.; Johnson, Eric W.; Robert Cunningham, J.; Still, Kenneth R.; Wilfong, Erin R.

    2006-01-01

    Depleted uranium (DU) projectiles have been used in battle in Iraq and the Balkans and will continue to be a significant armor-penetrating munition for the US military. As demonstrated in the Persian Gulf War, battle injury from DU projectiles and shrapnel is a possibility, and removal of embedded DU fragments from the body is not always practical because of their location in the body or their small size. Previous studies in rodents have demonstrated that implanted DU mobilizes and translocates to the gonads, and natural uranium may be toxic to spermatazoa and the male reproductive tract. In this study, the effects of implanted DU pellets on sperm concentration, motility, and male reproductive success were evaluated in adult (P1) Sprague-Dawley rats implanted with 0, 12, or 20, DU pellets of 1x2 mm or 12 or 20 tantalum (Ta) steel pellets of 1x2 mm. Twenty DU pellets of 1x2 mm (760 mg) implanted in a 500-g rat are equal to approximately 0.2 pound of DU in a 154-lb (70-kg) person. Urinary analysis found that male rats implanted with DU were excreting uranium at postimplantation days 27 and 117 with the amount dependent on dose. No deaths or evidence of toxicity occurred in P1 males over the 150-day postimplantation study period. When assessed at postimplantation day 150, the concentration, motion, and velocity of sperm isolated from DU-implanted animals were not significantly different from those of sham surgery controls. Velocity and motion of sperm isolated from rats treated with the positive control compound α-chlorohydrin were significantly reduced compared with sham surgery controls. There was no evidence of a detrimental effect of DU implantation on mating success at 30-45 days and 120-145 days postimplantation. The results of this study suggest that implantation of up to 20 DU pellets of 1x2 mm in rats for approximately 21% of their adult lifespan does not have an adverse impact on male reproductive success, sperm concentration, or sperm velocity

  1. Late occurring lesions in the skin of rats after repeated doses of X-rays

    International Nuclear Information System (INIS)

    Hopewell, J.W.

    1985-01-01

    Late radiation damage, characterized by atrophy and necrosis in the skin and subcutaneous tissues, has been demonstrated in both the tail and feet of rats. The incidence of necrosis increased with total dose. These total doses, in the range 72-144 Gy, were given as 4-8 treatment of 18 Gy, each dose separated from the next by an interval of 28 days. This treatment protocol minimized acute epithelial skin reactions. The same regime applied to the skin on the back of rats resulted in a very severe acute reaction occurring after the second to fifth dose of 18 Gy. This was surprising since back skin, like tail skin, is less sensitive to large single doses of radiation than that of the foot. The late radiation reaction in the foot and tail of rats are compared and contrasted with other attempts to assess late effects in rodent skin and with late changes seen in pig skin. (author)

  2. Shape memory effect and superelasticity of titanium nickelide alloys implanted with high ion doses

    International Nuclear Information System (INIS)

    Pogrebnjak, A D; Bratushka, S N; Beresnev, V M; Levintant-Zayonts, N

    2013-01-01

    The state of the art in ion implantation of superelastic NiTi shape memory alloys is analyzed. Various technological applications of the shape memory effect are outlined. The principles and techiques of ion implantation are described. Specific features of its application for modification of surface layers in surface engineering are considered. Key properties of shape memory alloys and problems in utilization of ion implantation to improve the surface properties of shape memory alloys, such as corrosion resistance, friction coefficient, wear resistance, etc. are discussed. The bibliography includes 162 references

  3. Response of rat spinal cord to single and fractionated doses of accelerated heavy ions

    International Nuclear Information System (INIS)

    Leith, J.T.; McDonald, M.; Powers-Risius, P.; Bliven, S.F.; Howard, J.

    1982-01-01

    The thoraco-lumbar (T12-L1) region of the spinal cord of rats was exposed to either single or fractionated (four daily exposures) doses of X rays (230 kVp) or heavy ions. The heavy ions used were carbon and neon, and the relative biological effectiveness (RBE) of both the plateau ionization region and the midpeak region of 4-cm spread-out Bragg peaks of each heavy ion were investigated. For single doses of carbon and neon ions in the plateau ionization region, RBE values of 1.45 +/- 0.25 (propagated 95% confidence limits) and 1.46 +/- 0.33, respectively, were obtained. In the spread peak regions for carbon and neon ions, the RBE values were 1.48 +/- 0.18 and 1.86 +/- 0.42, respectively. These values were obtained using the dose needed to produce 50% paralysis in a group of irradiated rats as the isoeffect comparison dose (ED 50 dose). Similarly, in groups of rats receiving four daily exposures, the RBE values for carbon and neon ions in the plateau ionization region were 1.31 +/- 0.27 and 1.80 +/- 0.24, respectively. In the spread peak regions of ionization for carbon and neon ions, the RBE values were 1.95 +/- 0.19 and 2.18 +/- 0.23, respectively. Similar values for RBE were obtained using changes in the activity of enzymes in spinal cord tissue (cyclic nucleotide phosphohydrolase and γ-glutamyl transpeptidase). Also, it was estimated that, for X irradiation, the fractional amount of dose repaired (at the ED 50 dose) was 0.64 +/- 0.10 (95% confidence limits). For carbon and neon ions in the plateau ionization region, the values for the fractional amount of dose repaired were 0.70 +/- 0.27 and 0.48 +/- 0.20, and for carbon and neon ions in the spread peak region of ionization, the fractional repair values were 0.40 +/- 0.10 and 0.52 +/- 0.17. Spinal cord tissue therefore shows a high capacity for subeffective damage repair

  4. Surface damage of 316 stainless steel irradiated with 4He+ to high doses

    International Nuclear Information System (INIS)

    Kaminsky, M.; Das, S.K.

    1978-01-01

    Surface blistering of niobium by implantation with helium ions in the 9 to 15 keV range was investigated. The apparent disappearance of blisters at sufficiently high doses was believed to be an equilibrium effect. To determine whether high temperature annealing causes the equilibrium condition, stainless steel-316 samples were irradiated at a constant 450 0 C. Results are presented

  5. Dose dependent transfer of 203lead to milk and tissue uptake in suckling offspring studied in rats and mice

    International Nuclear Information System (INIS)

    Palminger Hallen, I.; Oskarsson, A.

    1993-01-01

    The dose-dependent transfer of 203 Pb to milk and uptake in suckling rats and mice during a three-day nursing period was studied. On day 14 of lactation, the dams were administered a single intravenous dose of lead, labelled with 203 Pb, in four or five doses from 0.0005 to 2.0 mg Pb/kg b.wt. There was a linear relationship between Pb levels in plasma and milk of both species. The Pb milk: plasma ratios at 24 hr after administration were 119 and 89 in mice and rats, respectively. At 72 hr the Pb milk: plasma ratio had decreased to 72 in mice and 35 in rats. The tissue levels of lead in the suckling rats and mice were also linearly correlated with lead concentration in milk at 72 hr, showing that milk could be used as an indicator of lead exposure to the suckling offspring. It is concluded that lead is transported into rat and mouse milk to a very high extent and the excretion into milk is more efficient in mice than in rats. On the other hand, rat pups had higher lead levels in tissues than mice pups, which might be due to a higher bioavailability and/or a lower excretion of lead in rat pups. Thus, lead in breast milk could be used as a biological indicator of lead exposure in the mother as well as in the suckling offspring. (au) (38 refs.)

  6. Effects of melatonin in rats in the initial third stage of pregnancy exposed to sub-lethal doses of herbicides.

    Science.gov (United States)

    Almeida, Lécio Leone de; Teixeira, Álvaro Aguiar Coelho; Soares, Anísio Francisco; Cunha, Franklin Magliano da; Silva, Valdemiro Amaro da; Vieira Filho, Leucio Duarte; Wanderley-Teixeira, Valéria

    2017-04-01

    Exposure to the herbicides Paraquat (PQ) and Roundup ® may cause cell lesions due to an increase in oxidative stress levels in different biological systems, even in the reproductive system. Evaluate the possible changes in reproductive parameters and hepatic, as well as its prevention by simultaneous application of melatonin. Thirty-five female rats at the age of 3 months were divided into seven groups: three groups exposed to sub-lethal doses of the herbicides PQ (50mg/kg) and Roundup ® (500mg/kg) (n=5, G2, G3 and G4); three groups exposed to herbicides and simultaneous treatment with 10mg/kg of Melatonin (n=5, G5, G6 and G7) and control group (n=5, G1) from the first to the seventh day of pregnancy. On the seventh day of pregnancy, the rats were anesthetized and euthanized, followed by laparotomy to remove their reproductive tissues and liver. Body and ovary weights were taken and the number of implantation sites, corpora lutea, preimplantation losses, implantation rates were counted and histopathology of the implantation sites, morphometry of the surface and glandular epithelia of endometrium and hepatic oxidative stress were undertaken. The present study shows the decrease in body and ovary weight, decrease in the number of implantation sites, implantation rate, in the total number of corpora lutea and increase of preimplantation percentages were observed when compared to the G1: Fig. 1 and Table 1, (p>0.001 ANOVA/Tukey). The histopathological analysis of the implantation sites showed a disorder of the cytotrophoblast and cell degeneration within the blastocyst cavity in Fig. 4. Morphometry revealed a reduction in surface and glandular epithelia and in the diameter of the endometrial glands (Table 2; p>0.05 ANOVA/Tukey), whereas in liver, serum levels of thiobarbituric acid reactive substances (TBARS) were found to be significantly elevated (Fig. 2; p>0.001; p>0.05 ANOVA/Tukey), and serum level of reduced glutathione (GSH) was significantly lower (Fig. 3; p>0

  7. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Chung, J [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-06-15

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy.

  8. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    International Nuclear Information System (INIS)

    Lee, J; Chung, J

    2015-01-01

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy

  9. Dopant redistribution and electrical activation in silicon following ultra-low energy boron implantation and excimer laser annealing

    International Nuclear Information System (INIS)

    Whelan, S.; La Magna, A.; Privitera, V.; Mannino, G.; Italia, M.; Bongiorno, C.; Fortunato, G.; Mariucci, L.

    2003-01-01

    Excimer laser annealing (ELA) of ultra-low-energy (ULE) B-ion implanted Si has been performed. High-resolution transmission electron microscopy has been used to assess the as-implanted damage and the crystal recovery following ELA. The electrical activation and redistribution of B in Si during ELA has been investigated as a function of the laser energy density (melted depth), the implant dose, and the number of laser pulses (melt time). The activated and retained dose has been evaluated with spreading resistance profiling and secondary ion mass spectrometry. A significant amount of the implanted dopant was lost from the sample during ELA. However, the dopant that was retained in crystal material was fully activated following rapid resolidification. At an atomic concentration below the thermodynamic limit, the activation efficiency (dose activated/dose implanted into Si material) was a constant for a fixed melt depth, irrespective of the dose implanted and hence the total activated dose was raised as the implant dose was increased. The electrical activation was increased for high laser energy density annealing when the dopant was redistributed over a deeper range

  10. The Effect of Long-Term Intranasal Serotonin Treatment on Metabolic Parameters and Hormonal Signaling in Rats with High-Fat Diet/Low-Dose Streptozotocin-Induced Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Kira V. Derkach

    2015-01-01

    Full Text Available In the last years the treatment of type 2 diabetes mellitus (DM2 was carried out using regulators of the brain signaling systems. In DM2 the level of the brain serotonin is reduced. So far, the effect of the increase of the brain serotonin level on DM2-induced metabolic and hormonal abnormalities has been studied scarcely. The present work was undertaken with the aim of filling this gap. DM2 was induced in male rats by 150-day high-fat diet and the treatment with low dose of streptozotocin (25 mg/kg on the 70th day of experiment. From the 90th day, diabetic rats received for two months intranasal serotonin (IS at a daily dose of 20 μg/rat. The IS treatment of diabetic rats decreased the body weight, and improved glucose tolerance, insulin-induced glucose utilization, and lipid metabolism. Besides, it restored hormonal regulation of adenylyl cyclase (AC activity in the hypothalamus and normalized AC stimulation by β-adrenergic agonists in the myocardium. In nondiabetic rats the same treatment induced metabolic and hormonal alterations, some of which were similar to those in DM2 but expressed to a lesser extent. In conclusion, the elevation of the brain serotonin level may be regarded as an effective approach to treat DM2 and its complications.

  11. Protective and Therapeutic Role of Low Dose Gamma Radiation on Streptozotocin Induced Diabetes in Rats

    International Nuclear Information System (INIS)

    Mansour, H.H.; Hafez, H.F.; Shouman, S.A.

    2011-01-01

    Diabetes mellitus is a multi-factorial disease which is characterized by vascular and renal complication. This study was initiated to investigate the protective and the therapeutic effect of low dose of gamma radiation (LDR) on diabetic complications. A total of 30 adult male rats were divided into 5 groups: Group I: served as control and injected intraperitoneally with 0.2 ml of 0.1 mol/l citrate buffer (ph 4.5), group II: rats became diabetic via intraperitoneal injection with 60 mg/kg streptozotocin (STZ) dissolved in 0.2 ml of 0.1 mol/l citrate buffer (ph 4.5), group III irradiated rats (IRR): submitted to fractionated dose of whole body gamma rays; 0.25 Gy for 2 consecutive days (whole dose 0.5 Gy), group IV diabetic irradiated rats (STZ + IRR): rats became diabetic as group II then four weeks after diabetes induction (day 28), rats were submitted to 2 fractions of whole body gamma rays as in group III, and group V irradiated diabetic rats (IRR + STZ): rats were injected intraperitoneally with 0.2 ml of 0.1 mol/l citrate buffer then submitted to whole body gamma rays; 0.25 Gy for 2 consecutive days then one hour after the last IRR dose, rats were made diabetic as group II. In pre and post-irradiation of STZ rats, significant changes were observed in serum lipid profiles, hepatic and cardiac serum enzymes. Significant decrease in hepatic and cardiac malondialdehyde (MDA) and total nitrate/nitrite (NO(x)) levels, and significant increase in superoxide dismutase (SOD) and glutathione (GSH) levels were observed as compared to diabetic group. The study suggests that LDR may provide useful protective and therapeutic option in the reversal of oxidative stress induced in diabetic rats

  12. Monte Carlo simulation of radiation transport and dose deposition from locally released gold nanoparticles labeled with 111In, 177Lu or 90Y incorporated into tissue implantable depots

    Science.gov (United States)

    Lai, Priscilla; Cai, Zhongli; Pignol, Jean-Philippe; Lechtman, Eli; Mashouf, Shahram; Lu, Yijie; Winnik, Mitchell A.; Jaffray, David A.; Reilly, Raymond M.

    2017-11-01

    Permanent seed implantation (PSI) brachytherapy is a highly conformal form of radiation therapy but is challenged with dose inhomogeneity due to its utilization of low energy radiation sources. Gold nanoparticles (AuNP) conjugated with electron emitting radionuclides have recently been developed as a novel form of brachytherapy and can aid in homogenizing dose through physical distribution of radiolabeled AuNP when injected intratumorally (IT) in suspension. However, the distribution is unpredictable and precise placement of many injections would be difficult. Previously, we reported the design of a nanoparticle depot (NPD) that can be implanted using PSI techniques and which facilitates controlled release of AuNP. We report here the 3D dose distribution resulting from a NPD incorporating AuNP labeled with electron emitters (90Y, 177Lu, 111In) of different energies using Monte Carlo based voxel level dosimetry. The MCNP5 Monte Carlo radiation transport code was used to assess differences in dose distribution from simulated NPD and conventional brachytherapy sources, positioned in breast tissue simulating material. We further compare these dose distributions in mice bearing subcutaneous human breast cancer xenografts implanted with 177Lu-AuNP NPD, or injected IT with 177Lu-AuNP in suspension. The radioactivity distributions were derived from registered SPECT/CT images and time-dependent dose was estimated. Results demonstrated that the dose distribution from NPD reduced the maximum dose 3-fold when compared to conventional seeds. For simulated NPD, as well as NPD implanted in vivo, 90Y delivered the most homogeneous dose distribution. The tumor radioactivity in mice IT injected with 177Lu-AuNP redistributed while radioactivity in the NPD remained confined to the implant site. The dose distribution from radiolabeled AuNP NPD were predictable and concentric in contrast to IT injected radiolabeled AuNP, which provided irregular and temporally variant dose distributions

  13. Sex- and dose-dependency in the pharmacokinetics and pharmacodynamics of (+)-methamphetamine and its metabolite (+)-amphetamine in rats

    International Nuclear Information System (INIS)

    Milesi-Halle, Alessandra; Hendrickson, Howard P.; Laurenzana, Elizabeth M.; Gentry, W. Brooks; Owens, S. Michael

    2005-01-01

    These studies investigated how (+)-methamphetamine (METH) dose and rat sex affect the pharmacological response to METH in Sprague-Dawley rats. The first set of experiments determined the pharmacokinetics of METH and its pharmacologically active metabolite (+)-amphetamine (AMP) in male and female Sprague-Dawley rats after 1.0 and 3.0 mg/kg METH doses. The results showed significant sex-dependent changes in METH pharmacokinetics, and females formed significantly lower amounts of AMP. While the area under the serum concentration-time curve in males increased proportionately with the METH dose, the females showed a disproportional increase. The sex differences in systemic clearance, renal clearance, volume of distribution, and percentage of unchanged METH eliminated in the urine suggested dose-dependent pharmacokinetics in female rats. The second set of studies sought to determine the behavioral implications of these pharmacokinetic differences by quantifying locomotor activity in male and female rats after saline, 1.0, and 3.0 mg/kg METH. The results showed sex- and dose-dependent differences in METH-induced locomotion, including profound differences in the temporal profile of effects at higher dose. These findings show that the pharmacokinetic and metabolic profile of METH (slower METH clearance and lower AMP metabolite formation) plays a significant role in the differential pharmacological response to METH in male and female rats

  14. Analysis of buried etch-stop layers in silicon by nitrogen-ion implantation

    International Nuclear Information System (INIS)

    Acero, M.C.; Esteve, J.; Montserrat, J.; Perez-Rodriguez, A.; Garrido, B.; Romano-Rodriguez, A.; Morante, J.R.

    1993-01-01

    The analysis of the etch-stop properties of layers obtained by substoichiometric nitrogen-ion implantation and annealing in silicon has been performed as a function of the implantation conditions. The analysis of the etching efficiency has been tested in TMAH-IPA systems. The results obtained show the need to implant at doses higher than 2 x 10 17 cm -2 to obtain etch-stop layers stable under high-temperature annealing. So, for implantation doses of 5 x 10 17 cm -2 , layers stand unetched for times longer than 2 h. The preliminary structural analysis of the samples suggests the presence of an amorphous silicon nitride layer for higher implantation doses. (author)

  15. Low-dose effects of bisphenol A on early sexual development in male and female rats

    DEFF Research Database (Denmark)

    Christiansen, Sofie; Petersen, Marta Axelstad; Boberg, Julie

    2014-01-01

    the influence of BPA on early sexual development in male and female rats at dose levels covering both regulatory no observed adverse effect levels (NOAELs) (5 and 50 mg/kg bw per day) as well as doses in the microgram per kilogram dose range (0.025 and 0.25 mg/kg bw per day). Time-mated Wistar rats (n=22) were...... in both sexes indicates effects on prenatal sexual development and provides new evidence of low-dose adverse effects of BPA in rats in the microgram per kilogram dose range. The NOAEL in this study is clearly below 5 mg/kg for BPA, which is used as the basis for establishment of the current tolerable......Bisphenol A (BPA) is widely detected in human urine and blood. BPA has been reported to impair many endpoints for reproductive and neurological development; however, it is controversial whether BPA has effects in the microgram per kilogram dose range. The aim of the current study was to examine...

  16. Dose dependent effect of progesterone on hypoxic ventilatory response in newborn rats.

    Science.gov (United States)

    Hichri, Oubeidallah; Laurin, Jean-C; Julien, Cécile A; Joseph, Vincent; Bairam, Aida

    2012-01-01

    The effect of progesterone as a respiratory stimulant in newborn subjects is less known than that in adults. This study investigated the dose-response curve (0, 2, 4, and 8 mg/kg, ip) of progesterone on ventilation in non-anesthetized newborn rats at 4- and 12-days old using plethysmography. Progesterone had no effects in the regulation of normoxic ventilation. However, it enhanced the response to moderate hypoxia (FiO(2) 12%, 20 min) in 4- but not in 12-days old pups. This response was similar between the dose of 4 and 8 mg/kg. These observations suggested that progesterone enhances in age- and dose-dependent manner the hypoxic ventilatory response in newborn rats.

  17. Low energy ion implantation and high energy heavy ion irradiation in C60 films

    International Nuclear Information System (INIS)

    Narayanan, K.L.; Yamaguchi, M.; Dharmarasu, N.; Kojima, N.; Kanjilal, D.

    2001-01-01

    C 60 films have been bombarded with low energy boron ions and high energy swift heavy ions (SHI) of silver and oxygen at different doses. Raman scattering and Fourier transform infrared (FTIR) studies were carried out on the virgin and irradiated films and the results are in good agreement with each other. The films subject to low energy boron ion implantation showed destruction of the bukky balls whereas the films subject to high energy ion irradiation did not show appreciable effects on their structure. These results indicate that C 60 films are more prone to defects by elastic collision and subsequent implantation at lower energy. Irradiation at higher energy was less effective in creating appreciable defects through electronic excitation by inelastic collisions at similar energy density

  18. Effects of estrogen and gender on cataractogenesis induced by high-LET radiation

    International Nuclear Information System (INIS)

    Henderson, M.A.; Rusek, A.; Valluri, S.; Garrett, J.; Lopez, J.; Caperell-Grant, A.; Mendonca, M.; Bigsby, R.; Dynlacht, J.

    2010-01-01

    Planning for long-duration manned lunar and interplanetary missions requires an understanding of radiation-induced cataractogenesis. Previously, it was demonstrated that low-linear energy transfer (LET) irradiation with 10 Gy of 60 Co γ rays resulted in an increased incidence of cataracts in male rats compared to female rats. This gender difference was not due to differences in estrogen, since male rats treated with the major secreted estrogen 17-β-estradiol (E2) showed an identical increase compared to untreated males. We now compare the incidence and rate of progression of cataracts induced by high-LET radiation in male and female Sprague-Dawley rats. Rats received a single dose of 1 Gy of 600 MeV 56 Fe ions. Lens opacification was measured at 2-4 week intervals with a slit lamp. The incidence and rate of progression of radiation-induced cataracts was significantly increased in the animals in which estrogen was available from endogenous or exogenous sources. Male rats with E2 capsules implanted had significantly higher rates of progression compared to male rats with empty capsules implanted (P = 0.025) but not compared to the intact female rats. These results contrast with data obtained after low-LET irradiation and suggest the possibility that the different types of damage caused by high- and low-LET radiation may be influenced differentially by steroid sex hormones.

  19. Role of hormonal therapy in the management of intermediate- to high-risk prostate cancer treated with permanent radioactive seed implantation

    International Nuclear Information System (INIS)

    Lee, Lucille N.; Stock, Richard G.; Stone, Nelson N.

    2002-01-01

    Purpose: To study the impact of hormonal therapy (HTx) on intermediate- to high-risk prostate cancer treated with permanent radioactive seed implantation. Methods and Materials: Patients with Stage T1b-T3bN0 prostate cancer, and Gleason score ≥7 or prostate-specific antigen (PSA) level >10 ng/mL were treated with seed implantation with or without HTx. Their disease was defined as intermediate risk (PSA 10-20, Gleason score 7, or Stage T2b) or high risk (two or more intermediate criteria, or PSA >20 ng/mL, Gleason score 8-10, or Stage T2c-T3). The median follow-up for 201 eligible patients was 42 months (range 18-110). Biochemical failure was defined as a rising PSA >1.0 ng/mL. Pretreatment disease characteristics, implant dose, and HTx were evaluated using univariate and multivariate analyses. Results: HTx significantly improved 5-year actuarial freedom from biochemical failure rate, 79% vs. 54% without HTx. In addition, high-dose, PSA ≤15 ng/mL, intermediate risk, and Stage T2a or lower significantly improved outcome in the univariate analyses. HTx was the most significant predictor of 5-year actuarial freedom from biochemical failure (p <0.0001) in a multivariate analysis. The best outcome was in the intermediate-risk patients treated with a high implant dose and HTx, resulting in a 4-year actuarial freedom from biochemical failure rate of 94%. Conclusion: In this retrospective review, HTx improved outcome in intermediate- to high-risk prostate cancer patients treated with brachytherapy. HTx was the most important prognostic factor in the univariate and multivariate analyses

  20. Forming of nanocrystal silicon films by implantation of high dose of H+ in layers of silicon on isolator and following fast thermal annealing

    International Nuclear Information System (INIS)

    Tyschenko, I.E.; Popov, V.P.; Talochkin, A.B.; Gutakovskij, A.K.; Zhuravlev, K.S.

    2004-01-01

    Formation of nanocrystalline silicon films during rapid thermal annealing of the high-dose H + ion implanted silicon-on-insulator structures was studied. It was found, that Si nanocrystals had formed alter annealings at 300-400 deg C, their formation being strongly limited by the hydrogen content in silicon and also by the annealing time. It was supposed that the nucleation of crystalline phase occurred inside the silicon islands between micropores. It is conditioned by ordering Si-Si bonds as hydrogen atoms are leaving their sites in silicon network. No coalescence of micropores takes place during the rapid thermal annealing at the temperatures up to ∼ 900 deg C. Green-orange photoluminescence was observed on synthesized films at room temperature [ru

  1. The screening of bacillus subtilis strain with high-produced antimicrobial substance using N+ ion implantation

    International Nuclear Information System (INIS)

    Shen Juan; Bie Xiaomei; Lu Zhaoxin; Lu Fengxia; Zhu Xiaoyu

    2006-01-01

    N + ion implantation was used to obtain higher-yield antimicrobial substance. Bacillus subtilis fmbJ was mutated by 25 keV N + ion implantation with the dose of 50 x 2.6 x 10 13 , 80 x 2.6 x 10 13 , 100 x 2.6 x 10 13 , 120 x 2.6 x 10 13 and 150 x 2.6 x 10 13 N + /m 2 . Results showed that the optimal N + ion dose was 50 x 2.6 x 10 13 N + /m 2 , and a strain of high-yield antimicrobials was obtained and named as Bacillus subtilis fmbJ224. Its antimicrobial substance yield was increased by 96% than the initial. The fermentation characteristic of the strain was studied, and the mode of producing antimicrobial substance for the selected strain was arrearage synthesis type. (authors)

  2. Behavioral and physiological changes produced by a supralethal dose of ionizing radiation: evidence for hormone-influenced sex differences in the rat

    International Nuclear Information System (INIS)

    Mickley, G.A.

    1980-01-01

    A sufficiently large and rapid dose of ionizing radiation produces an immediate but transient behavioral incapacitation. Acute hypotension often accompanies the disorder. Although the etiology of this syndrome is unclear, it has been suggested that an increase in histamine excretion contributes to it. Since histamine is known to interact with the endocrine system and since estrogens have been shown to prolong the life of animals exposed to potentially lethal doses of radiation, it was also hypothesized that females might be relatively less affected by an acute, large dose of ionizing radiation. Male and female rats were trained on an avoidance task, irradiated, and then retested. Females showed a less severe decrement after radiation exposure than males. Likewise, females did not suffer the severe hypotension normally associated with male radiogenic early transient incapacitation (ETI); rather, an acute hypertension was produced in females. A second series of experiments revealed that differences in male and female radiation response were eliminated by gonadectomy. Systemic estradiol injection produced strikingly feminine (i.e., superior) postirradiation avoidance responses as well as hypertension in neutered rats. Testosterone injections had no effect on either measure. Central nervous system alterations have been correlated with the ETI. Therefore, final experiments sought a possible central locus of the action of estradiol. It was found that exposure of the nucleus peopticus medialis to estrogens produces postirradiation benefits in avoidance performance and blood pressure similar to those seen after systemic estradiol treatments. Nucleus amygdaloideus medialis implants produced no such benefits

  3. SU-F-T-43: Prediction of Dose Increments by Brain Metastases Resection Cavity Shrinkage Model with I-125 and Cs-131 LDR Seed Implantations

    Energy Technology Data Exchange (ETDEWEB)

    Han, D; Braunstein, S; Sneed, P; McDermott, M; Ma, L [University of California San Francisco, San Francisco, CA (United States)

    2016-06-15

    Purpose: This work aims to determine dose variability via a brain metastases resection cavity shrinkage model (RC-SM) with I-125 or Cs-131 LDR seed implantations. Methods: The RC-SM was developed to represent sequential volume changes of 95 consecutive brain metastases patients. All patients underwent serial surveillance MR and change in cavity volume was recorded for each patient. For the initial resection cavity, a prolate-ellipsoid cavity model was suggested and applied volume shrinkage rates to correspond to 1.7, 3.6, 5.9, 11.7, and 20.5 months after craniotomy. Extra-ring structure (6mm) was added on a surface of the resection volume and the same shrinkage rates were applied. Total 31 LDR seeds were evenly distributed on the surface of the resection cavity. The Amersham 6711 I-125 seed model (Oncura, Arlington Heights, IL) and the Model Cs-1 Rev2 Cs-131 seed model (IsoRay, Richland, WA) were used for TG-43U1 dose calculation and in-house-programed 3D-volumetric dose calculation system was used for resection cavity rigid model (RC-RM) and the RC-SM dose calculation. Results: The initial resection cavity volume shrunk to 25±6%, 35±6.8%, 42±7.7%, 47±9.5%, and 60±11.6%, with respect to sequential MR images post craniotomy, and the shrinkage rate (SR) was calculated as SR=56.41Xexp(−0.2024Xt)+33.99 and R-square value was 0.98. The normal brain dose as assessed via the dose to the ring structure with the RC-SM showed 29.34% and 27.95% higher than the RC-RM, I-125 and Cs-131, respectively. The dose differences between I-125 and Cs-131 seeds within the same models, I-125 cases were 9.17% and 10.35% higher than Cs-131 cases, the RC-RM and the RC-SM, respectively. Conclusion: A realistic RC-SM should be considered during LDR brain seed implementation and post-implement planning to prevent potential overdose. The RC-SM calculation shows that Cs-131 is more advantageous in sparing normal brain as the resection cavity volume changes with the LDR seeds implementation.

  4. Tissue response to a new type of biomaterial implanted subcutaneously in rats

    DEFF Research Database (Denmark)

    Boennelycke, Marie; Christensen, Lise; Nielsen, Lene Feldskov

    2011-01-01

    -cellular matrix (ECM) or estrogen. Methods Ten implants of each type were tested for 3 and 8 weeks, respectively. Histological assessment of connective tissue organization, inflammation, vascularization, and thickness of regenerated tissue was undertaken. Results All implants had a high degree of biocompatibility....... ECM-enriched implants had significantly higher inflammatory scores compared to pure implants at 3 weeks. At 8 weeks, neither of the parameters differed significantly. No trace of the implants remained. Conclusions The MPEG-PLGA is highly biocompatible, degrades quickly, and seems inert in the process...

  5. Response of rat spinal cord to single and fractionated doses of accelerated heavy ions

    International Nuclear Information System (INIS)

    Leith, J.L.; McDonald, M.; Powers-Risius, P.; Bliven, S.F.; Walton, R.E.; Woodruff, K.H.; Howard, J.

    1980-01-01

    The response of rat spinal cord to irradiation with accelerated heavy ions, in particular carbon and neon ions has been studied. Two different ionization regions in the modified Bragg curve for each ion have been studied for both single and fractionated exposures. We have defined the paralytic response as a function of dose and dose per fraction, and we have determined RBE and repair values. The response of rat spinal cord is both dose and LET dependent, which allows the derivation of RBE and repair values

  6. Chronic intrathecal cannulation enhances nociceptive responses in rats

    Directory of Open Access Journals (Sweden)

    Almeida F.R.C.

    2000-01-01

    Full Text Available The influence of a chronically implanted spinal cannula on the nociceptive response induced by mechanical, chemical or thermal stimuli was evaluated. The hyperalgesia in response to mechanical stimulation induced by carrageenin or prostaglandin E2 (PGE2 was significantly increased in cannulated (Cn rats, compared with naive (Nv or sham-operated (Sh rats. Only Cn animals presented an enhanced nociceptive response in the first phase of the formalin test when low doses were used (0.3 and 1%. The withdrawal latency to thermal stimulation of a paw inflamed by carrageenin was significantly reduced in Cn rats but not in Nv or Sh rats. In contrast to Nv and Sh rats, injection in Cn animals of a standard non-steroid anti-inflammatory drug, indomethacin, either intraperitoneally or into the spinal cord via an implanted cannula or by direct puncture of the intrathecal space significantly blocked the intensity of the hyperalgesia induced by PGE2. Cannulated animals treated with indomethacin also showed a significant inhibition of second phase formalin-induced paw flinches. Histopathological analysis of the spinal cord showed an increased frequency of mononuclear inflammatory cells in the Cn groups. Thus, the presence of a chronically implanted cannula seems to cause nociceptive spinal sensitization to mechanical, chemical and thermal stimulation, which can be blocked by indomethacin, thus suggesting that it may result from the spinal release of prostaglandins due to an ongoing mild inflammation.

  7. α-Amyrin attenuates high fructose diet-induced metabolic syndrome in rats.

    Science.gov (United States)

    Prabhakar, Pankaj; Reeta, K H; Maulik, Subir Kumar; Dinda, Amit Kumar; Gupta, Yogendra Kumar

    2017-01-01

    This study investigated the effect of α-amyrin (a pentacyclic triterpene) on high-fructose diet (HFD)-induced metabolic syndrome in rats. Male Wistar rats were randomly distributed into different groups. The control group was fed normal rat chow diet. The HFD group was fed HFD (60%; w/w) for 42 days. Pioglitazone (10 mg/kg, orally, once daily) was used as a standard drug. α-Amyrin was administered in 3 doses (50, 100, and 200 mg/kg, orally, once daily along with HFD). Plasma glucose, total cholesterol, triglycerides, and high-density lipoprotein cholesterol (HDL-C) were estimated. Changes in blood pressure, oral glucose tolerance, and insulin tolerance were measured. Hepatic oxidative stress as well as messenger RNA (mRNA) and protein levels of peroxisome proliferator-activated receptor alpha (PPAR-α) were analyzed. A significant increase in systolic blood pressure, plasma glucose, total cholesterol, and plasma triglycerides and a significant decrease in HDL-C were observed in HFD rats as compared with control rats. Glucose tolerance and insulin tolerance were also significantly impaired with HFD. α-Amyrin prevented these changes in a dose-dependent manner. Hepatic oxidative stress as well as micro- and macrovesicular fatty changes in hepatocytes caused by HFD were also attenuated by α-amyrin. α-Amyrin preserved the hepatic mRNA and protein levels of PPAR-α, which was reduced in HFD group. This study thus demonstrates that α-amyrin attenuates HFD-induced metabolic syndrome in rats.

  8. Maintained functionality of an implantable radiotelemetric blood pressure and heart rate sensor after magnetic resonance imaging in rats

    International Nuclear Information System (INIS)

    Nölte, I; Boll, H; Figueiredo, G; Groden, C; Brockmann, M A; Gorbey, S; Lemmer, B

    2011-01-01

    Radiotelemetric sensors for in vivo assessment of blood pressure and heart rate are widely used in animal research. MRI with implanted sensors is regarded as contraindicated as transmitter malfunction and injury of the animal may be caused. Moreover, artefacts are expected to compromise image evaluation. In vitro, the function of a radiotelemetric sensor (TA11PA-C10, Data Sciences International) after exposure to MRI up to 9.4 T was assessed. The magnetic force of the electromagnetic field on the sensor as well as radiofrequency (RF)-induced sensor heating was analysed. Finally, MRI with an implanted sensor was performed in a rat. Imaging artefacts were analysed at 3.0 and 9.4 T ex vivo and in vivo. Transmitted 24 h blood pressure and heart rate were compared before and after MRI to verify the integrity of the telemetric sensor. The function of the sensor was not altered by MRI up to 9.4 T. The maximum force exerted on the sensor was 273 ± 50 mN. RF-induced heating was ruled out. Artefacts impeded the assessment of the abdomen and thorax in a dead rat, but not of the head and neck. MRI with implanted radiotelemetric sensors is feasible in principal. The tested sensor maintains functionality up to 9.4 T. Artefacts hampered abdominal and throacic imaging in rats, while assessment of the head and neck is possible

  9. Performances of low-dose dual-energy CT in reducing artifacts from implanted metallic orthopedic devices

    Energy Technology Data Exchange (ETDEWEB)

    Filograna, Laura [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Department of Radiological Sciences, Institute of Radiology, Rome (Italy); University of Zurich, Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, Zurich (Switzerland); Magarelli, Nicola; Leone, Antonio; Bonomo, Lorenzo [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Department of Radiological Sciences, Institute of Radiology, Rome (Italy); De Waure, Chiara; Calabro, Giovanna Elisa [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Research Centre for Health Technology Assessment, Department of Public Health, Section of Hygiene, Rome (Italy); Finkenstaedt, Tim [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Thali, Michael John [University of Zurich, Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, Zurich (Switzerland)

    2016-07-15

    The objective was to evaluate the performances of dose-reduced dual-energy computed tomography (DECT) in decreasing metallic artifacts from orthopedic devices compared with dose-neutral DECT, dose-neutral single-energy computed tomography (SECT), and dose-reduced SECT. Thirty implants in 20 consecutive cadavers underwent both SECT and DECT at three fixed CT dose indexes (CTDI): 20.0, 10.0, and 5.0 mGy. Extrapolated monoenergetic DECT images at 64, 69, 88, 105, 120, and 130 keV, and individually adjusted monoenergy for optimized image quality (OPTkeV) were generated. In each group, the image quality of the seven monoenergetic images and of the SECT image was assessed qualitatively and quantitatively by visually rating and by measuring the maximum streak artifact respectively. The comparison between SECT and OPTkeV evaluated overall within all groups showed a significant difference (p <0.001), with OPTkeV images providing better images. Comparing OPTkeV with the other DECT images, a significant difference was shown (p <0.001), with OPTkeV and 130-keV images providing the qualitatively best results. The OPTkeV images of 5.0-mGy acquisitions provided percentages of images with scores 1 and 2 of 36 % and 30 % respectively, compared with 0 % and 33.3 % of the corresponding SECT images of 10- and 20-mGy acquisitions. Moreover, DECT reconstructions at the OPTkeV of the low-dose group showed higher CT numbers than the SECT images of dose groups 1 and 2. This study demonstrates that low-dose DECT permits a reduction of artifacts due to metallic implants to be obtained in a similar manner to neutral-dose DECT and better than reduced or neutral-dose SECT. (orig.)

  10. Influence of different doses of octenidine hexafluorosilicate on parodontotium state of rat, which received cariesogenic ration

    Directory of Open Access Journals (Sweden)

    V. Yu. Anisimov

    2017-06-01

    Full Text Available Aim: To determine of parodontium state of rat, which received cariesogenic ration and different doses of octenidine hexafluorosilicate (O-HFS. Methods: The octenidine hexafluorosilicate was synthesized by us and was used into mucoso-adgesive gels (Na-CMC in next concentrations: 1 mg/ml, 2 mg/ml and 4 mg/ml. The rats received high-sugar cariesogenic ration and oral applications of gels with O-HFS in doses of 0,3 ml (daily doses of O-HFS were 1,4 mg/kg, 2,8 mg/kg and 5,6 mg/kg. The duration of experiment was 35 days. The activities of urease, lysozyme and elastase were determined into gum. The activities of urease, lysozyme, ALT and alkaline phosphatase (APh were determined into serum. The degree of dysbiosis calculated by ration urease and lysozyme. The degree of atrophy of parodontale bone was determined by Nicolaeva method. Results: The activities of elastase and urease, the degree of atrophy and dysbiosis were raised into gum of rat, which received cariesogenic ration. The activities of ALT and APh, the degree of dysbiosis were raised into serum. The oral application of O-HFS-gels decreased the all these indices. The maximal action made O-HFS-gel in dose 2,8 mg/kg. Conclusion: The oral application of O-HFS-gel make parodontoprotective action.

  11. Athari za uhamishaji wa sarufi ya Kiluo kwenye upatanisho wa sarufi ...

    African Journals Online (AJOL)

    Viambishi vya upatanishi hutumiwa tu kikundi nomino kinapoundwa na kiwakilishi. Athari ya uhamishaji wa sarufi ya Kiluo kwenye sarufi ya Kiswahili ilibainika katika viwango vitatu vya kisarufi: ngeli, nafsi na idadi. Utafiti uliongozwa na nadharia ya Umilikifu na Uhusisho (Chomsky, 1981). Nadharia hii huonesha hali ya ...

  12. Microstructure evolution in carbon-ion implanted sapphire

    International Nuclear Information System (INIS)

    Orwa, J. O.; McCallum, J. C.; Jamieson, D. N.; Prawer, S.; Peng, J. L.; Rubanov, S.

    2010-01-01

    Carbon ions of MeV energy were implanted into sapphire to fluences of 1x10 17 or 2x10 17 cm -2 and thermally annealed in forming gas (4% H in Ar) for 1 h. Secondary ion mass spectroscopy results obtained from the lower dose implant showed retention of implanted carbon and accumulation of H near the end of range in the C implanted and annealed sample. Three distinct regions were identified by transmission electron microscopy of the implanted region in the higher dose implant. First, in the near surface region, was a low damage region (L 1 ) composed of crystalline sapphire and a high density of plateletlike defects. Underneath this was a thin, highly damaged and amorphized region (L 2 ) near the end of range in which a mixture of i-carbon and nanodiamond phases are present. Finally, there was a pristine, undamaged sapphire region (L 3 ) beyond the end of range. In the annealed sample some evidence of the presence of diamond nanoclusters was found deep within the implanted layer near the projected range of the C ions. These results are compared with our previous work on carbon implanted quartz in which nanodiamond phases were formed only a few tens of nanometers from the surface, a considerable distance from the projected range of the ions, suggesting that significant out diffusion of the implanted carbon had occurred.

  13. Postnatal development of resistance to short-term high-dose toxic effects of 2,3,7,8-tetrachlorodibenzo-p-dioxin in TCDD-resistant and -semiresistant rats

    International Nuclear Information System (INIS)

    Simanainen, Ulla; Tuomisto, Jouni T.; Pohjanvirta, Raimo; Syrjaelae, Paula; Tuomisto, Jouko; Viluksela, Matti

    2004-01-01

    Despite great interspecies differences in adult 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) sensitivity, the toxic potency of TCDD is similar across species in fetal mortality. Han/Wistar (Kuopio; H/W) rats are exceptionally resistant to acute toxicity of TCDD, but show sensitivity to embryotoxicity and teratogenicity. The resistance of adult H/W rats to acute TCDD toxicity is based on a point mutation in the transactivation domain of the aryl hydrocarbon receptor (AHR) and to an unknown gene ''B''. This study investigated the time course of postnatal development of resistance to TCDD and the significance of genotypic variation in resistance development. H/W, line A (a new line with the H/W-type mutated AHR), and line B rats (a line with normal AHR but moderately resistant because of gene ''B'') were exposed to a single dose of TCDD 2-56 days after birth. H/W and line A rats received 1000 μg/kg; male and female B rats received 200 and 100 μg/kg, respectively. Survival was monitored for 42 days. Interestingly, although TCDD ceased growth and weight gain in all TCDD groups, the younger dosed animals did not seem to reach the body weight of the older dosed animals even in 100 days. The survival results after 42 days showed that line A rats are fairly resistant to TCDD immediately after birth, and their full TCDD resistance develops during the first week of life. The moderate resistance of line B rats develops approximately at the time of weaning. This difference in the time course of resistance development suggests that there are basic differences in pathways mediating resistance in lines A and B rats

  14. Protective Effects of Tamarillo (Cyphomandra betacea Extract against High Fat Diet Induced Obesity in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Noor Atiqah Aizan Abdul Kadir

    2015-01-01

    Full Text Available This study aims to investigate the protective effect of Cyphomandra betacea in adult male Sprague-Dawley rats fed with high fat diet. Rats were fed on either normal chow or high fat diet for 10 weeks for obesity induction phase and subsequently received C. betacea extract at low dose (150 mg kg−1, medium dose (200 mg kg−1, or high dose (300 mg kg−1 or placebo via oral gavages for another 7 weeks for treatment phase. Treatment of obese rats with C. betacea extracts led to a significant decrease in total cholesterol and significant increase in HDL-C (p<0.05. Also there was a trend of positive reduction in blood glucose, triglyceride, and LDL-C with positive reduction of body weight detected in medium and high dosage of C. betacea extract. Interestingly, C. betacea treated rats showed positive improvement of superoxide dismutase (SOD activity and glutathione peroxidase (GPx activity along with a significant increase of total antioxidant status (TAS (p<0.05. Further, rats treated with C. betacea show significantly lower in TNF-α and IL-6 activities (p<0.05. This study demonstrates the potential use of Cyphomandra betacea extract for weight maintenance and complimentary therapy to suppress some obesity complication signs.

  15. Chronic blood pressure and appetite responses to central leptin infusion in rats fed a high fat diet.

    Science.gov (United States)

    Dubinion, John H; da Silva, Alexandre A; Hall, John E

    2011-04-01

    Obesity has been suggested to induce selective leptin resistance whereby leptin's anorexic effects are attenuated, whereas the effects to increase sympathetic nervous system activity and blood pressure remain intact. Most studies, however, have tested only the acute responses to leptin administration. This study tested whether feeding a high-fat diet causes resistance to the appetite and cardiovascular responses to chronic central leptin infusion. Sprague-Dawley rats were fed high-fat diet (40% kcal from fat, n=5) or normal-fat diet (13% kcal from fat, n=5) for a year. Radiotelemeters were implanted for continuous monitoring of mean arterial pressure (MAP) and heart rate (HR). A 21G steel cannula was implanted in the lateral cerebral ventricle [intracerebroventricular (ICV)]. After recovery, leptin was infused ICV at 0.02 μg/kg per min for 10 days. High-fat rats were heavier than normal-fat rats (582±12 vs. 511±19 g) and exhibited significantly higher MAP (114±3 vs. 96±7 mmHg). Although the acute (24 h) effects of leptin were attenuated in high-fat rats, chronic ICV leptin infusion decreased caloric intake in both groups similarly (50±8 vs. 40±10%) by day 5. Despite decreased food intake and weight loss, leptin infusion significantly increased MAP and HR in both high-fat and normal-fat rats (7±2 and 5±1 mmHg; 18±11 and 21±10 b.p.m., respectively). These results suggest that obesity induced by feeding a high-fat diet blunts the acute anorexic effects of leptin but does not cause significant resistance to the chronic central nervous system effects of leptin on appetite, MAP, or HR.

  16. Effect of ovariectomy and 17 beta-estradiol implantation on bone metabolism in female rats fed 1,25 dihydroxyvitamin D3

    International Nuclear Information System (INIS)

    Osborne, M.; Sherman, S.; Soares, J.H. Jr.

    1986-01-01

    Eight-week old Sprague-Dawley female rats were used in two experiments to test the effects of 17-B estradiol (E 2 ) via silastic tubing implants on 3 H-labelled tetracycline (TC) incorporation into bone. 1,25(OH) 2 D 3 was the dietary source of vitamin D in a low calcium (.2%) semipurified eggwhite diet. In experiment I, the Ovx + E 2 animals showed a significantly (p 3 H TC uptake in scapula during a 2-week labelling experiment. An increase in 3 H TC content resulted (p 2 was implanted in 1,25(OH) 2 D 3 fed Ovx rats. However, the calcium content was not significantly different. The effect of dietary 1,25(OH) 2 D 3 and E 2 implantation appears to be additive. Optimal action of the Vitamin D endocrine system may be dependent on presence of E 2

  17. Transport calculations of. gamma. -ray flux density and dose rate about implantable californium-252 sources

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, A; Lin, B I [Cincinnati Univ., Ohio (USA). Dept. of Chemical and Nuclear Engineering; Windham, J P; Kereiakes, J G

    1976-07-01

    ..gamma.. flux density and dose rate distributions have been calculated about implantable californium-252 sources for an infinite tissue medium. Point source flux densities as a function of energy and position were obtained from a discrete-ordinates calculation, and the flux densities were multiplied by their corresponding kerma factors and added to obtain point source dose rates. The point dose rates were integrated over the line source to obtain line dose rates. Container attenuation was accounted for by evaluating the point dose rate as a function of platinum thickness. Both primary and secondary flux densities and dose rates are presented. The agreement with an independent Monte Carlo calculation was excellent. The data presented should be useful for the design of new source configurations.

  18. Radioactive implants for medical applications; Radioaktive Implantate fuer medizinische Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, M.

    2008-07-01

    The long-term success of surgery is often diminished by excessive wound healing, which makes another intervention necessary. Locally applied radionuclides with short range radiation can prevent such benign hyperproliferation. As pure electron emitter with a half-life of 14.3 days and a mean energy of 694.9 keV (E{sub max}=1710.48 keV) {sup 32}P is a suitable radionuclide which can be produced from the stable {sup 31}P by the capture of thermal neutrons (1 x 10{sup 14} /s/cm{sup 2}) in a nuclear reactor. After a typical irradiation time (14 days) the ratio of {sup 32}P to {sup 31}P is 1.4 x 10{sup -5} to 1. Implants made of polymer and/or bioabsorbable material functioning as a carrier of the radioactive emitter allow - as opposed to metallic implants - for new applications for this type of radiotherapy. In this thesis a manufacturing method for previously not available organic, radioactive implants has been developed and a corresponding dosimetry system has been established. By means of ion implantation, {sup 32}P ions with up to 180 keV can be shot some 100 nm deep into organic implant materials. For a typical dose (15 Gy over 7 days, 1 mm distance from the implant) an activity of 75 kBq is needed corresponding to 1.3 x 10{sup 11} {sup 32}P ions. The sputter ion gun, which has been optimized for this application, creates an ion beam with high beam current (> 14 {mu}A P{sup -}) and low emittance (< 4 {pi} mm mrad {radical}(MeV)). Because of the good beam quality also small implants (<1 mm{sup 2}) can be manufactured with high efficiency. The unintentionally co-implanted portion of molecules and nuclides of the same mass (e.g. {sup 31}PH, {sup 16}O{sub 2} and {sup 32}S) could be reduced from approximately 500 to 50 by an improvement of the isotope selection at {sup 32}P beam creation. Hence, in comparison with the best hitherto existing implantation methods, the radiation dose of the implant could be reduced by an order of magnitude. With regard to the beta

  19. Dosimetric measurement of scattered radiation from dental implants in simulated head and neck radiotherapy.

    Science.gov (United States)

    Wang, R; Pillai, K; Jones, P K

    1998-01-01

    The purpose of this study was to examine the dose enhancement at bone-implant interfaces from scattered radiation during simulated head and neck radiotherapy. Three cylindric implant systems with different compositions (pure titanium, titanium-aluminum-vanadium alloy, titanium coated with hydroxyapatite) and a high gold content transmandibular implant system (gold-copper-silver alloy) were studied. Extruded lithium fluoride single crystal chips were used as thermoluminescent material to measure radiation dose enhancement at 0, 1, and 2 mm from the bone-implant interface. The relative doses in buccal, lingual, mesial, and distal directions were also recorded and compared. The results indicated that the highest dose enhancement occurred at a distance of 0 mm from the bone-implant interface for all the implant systems studied. The transmandibular implants had higher scattered radiation than other groups at 0 mm and at 1 mm from the bone-implant interface. There was no significant difference of dose enhancement between buccal, lingual, mesial, and distal directions. Titanium implants coated with hydroxyapatite demonstrated the best results under the simulated irradiation.

  20. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  1. Low dose DDT inhibition of hepatocarcinogenesis initiated by diethylnitrosamine in male rats: Possible mechanisms

    International Nuclear Information System (INIS)

    Kushida, Masahiko; Sukata, Tokuo; Uwagawa, Satoshi; Ozaki, Keisuke; Kinoshita, Anna; Wanibuchi, Hideki; Morimura, Keiichirou; Okuno, Yasuyoshi; Fukushima, Shoji

    2005-01-01

    Previously we reported a tendency for reduction of the development of glutathione-S-transferase placental form (GST-P) positive foci, recognized as preneoplastic changes in rat liver, by a low dose of 1,1-bis(p-chlorophenyl)-2,2,2-trichloroethane (DDT), which belongs to the same group of hepatic cytochrome P-450 inducers as phenobarbital and is itself a non-genotoxic hepatocarcinogen. In order to clarify the biological significance of this phenomenon, we investigated the reproducibility and changes in other parameters using an initiation-promotion model in which male F344 rats were treated with DDT at doses of 0, 0.005, 0.5, 500 ppm in the diet for 11 or 43 weeks after initiation of hepatocarcinogenesis with N-diethylnitrosamine (DEN). When 500 ppm DDT was applied, the formation of GST-P positive foci and tumor were markedly elevated. In contrast, induction of GST-P positive foci and liver tumors tended to be inhibited at a dose of 0.005 ppm, correlating with protein levels of cytochrome P450 2B1 and 3A2 (CYP2B1 and 3A2) and generation of 8-hydroxy-2'-deoxyguanosine (8-OHdG), a marker of oxidative DNA damage. mRNA levels for 8-oxoguanine glycosylase 1 (OGG1), an 8-OHdG repair enzyme, connexin 32 (Cx32), a major component of Gap junctions, and hepatic nuclear factor 1α (HNF-1α), a Cx32 regulator, were inversely correlated with GST-P positive foci and tumor formation. These results indicate that low dose DDT may indeed exhibit inhibitory effects on chemically initiated-rat hepatocarcinogenicity, in contrast to the promotion observed with high doses, and that this is related to changes in metabolizing enzymes, cell communication, and DNA damage and its repair

  2. Analysis of buried etch-stop layers in silicon by nitrogen-ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Acero, M.C.; Esteve, J.; Montserrat, J. (Centro Nacional de Microelectronica (CNM-CSIC), Bellaterra (Spain)); Perez-Rodriguez, A.; Garrido, B.; Romano-Rodriguez, A.; Morante, J.R. (Barcelona Univ. (Spain). Dept. Fisica Aplicada i Electronica)

    1993-09-01

    The analysis of the etch-stop properties of layers obtained by substoichiometric nitrogen-ion implantation and annealing in silicon has been performed as a function of the implantation conditions. The analysis of the etching efficiency has been tested in TMAH-IPA systems. The results obtained show the need to implant at doses higher than 2 x 10[sup 17] cm[sup -2] to obtain etch-stop layers stable under high-temperature annealing. So, for implantation doses of 5 x 10[sup 17] cm[sup -2], layers stand unetched for times longer than 2 h. The preliminary structural analysis of the samples suggests the presence of an amorphous silicon nitride layer for higher implantation doses. (author).

  3. Rat skin carcinogenesis as a basis for estimating risks at low doses and dose rates of various types of radiation

    International Nuclear Information System (INIS)

    Burns, F.J.; Vanderlaan, M.; Strickland, P.; Albert, R.E.

    1976-01-01

    The recovery rate, age dependence and latent period for tumor induction in rat skin were measured for single and split doses of radiation, and the data were analyzed in terms of a general model in an attempt to estimate the expected tumor response for various types of radiation given at low dose rates for long periods of time. The dorsal skin of male rats was exposed to electrons, x rays, or protons in either single or split doses for several doses and the tumor responses were compared during 80 weeks of observation. A two stage model incorporating a reversible or recoverable mode was developed and various parameters in the model, including recovery rate, dose-response coefficients, and indices of age sensitivity, were evaluated experimentally. The measured parameters were then utilized to calculate expected tumor responses for exposure periods extending for duration of life. The calculations indicated that low dose rates could be markedly ( 1 / 100 to 1 / 1000 ) less effective in producing tumors than the same dose given in a short or acute exposure, although the magnitude of the reduction in effectiveness declines as the dose declines

  4. High-Dose Estradiol-Replacement Therapy Enhances the Renal Vascular Response to Angiotensin II via an AT2-Receptor Dependent Mechanism

    Directory of Open Access Journals (Sweden)

    Tahereh Safari

    2015-01-01

    Full Text Available Physiological levels of estrogen appear to enhance angiotensin type 2 receptor- (AT2R- mediated vasodilatation. However, the effects of supraphysiological levels of estrogen, analogous to those achieved with high-dose estrogen replacement therapy in postmenopausal women, remain unknown. Therefore, we pretreated ovariectomized rats with a relatively high dose of estrogen (0.5 mg/kg/week for two weeks. Subsequently, renal hemodynamic responses to intravenous angiotensin II (Ang II, 30–300 ng/kg/min were tested under anesthesia, while renal perfusion pressure was held constant. The role of AT2R was examined by pretreating groups of rats with PD123319 or its vehicle. Renal blood flow (RBF decreased in a dose-related manner in response to Ang II. Responses to Ang II were enhanced by pretreatment with estradiol. For example, at 300 ng kg−1 min−1, Ang II reduced RBF by 45.7±1.9% in estradiol-treated rats but only by 27.3±5.1% in vehicle-treated rats. Pretreatment with PD123319 blunted the response of RBF to Ang II in estradiol-treated rats, so that reductions in RBF were similar to those in rats not treated with estradiol. We conclude that supraphysiological levels of estrogen promote AT2R-mediated renal vasoconstriction. This mechanism could potentially contribute to the increased risk of cardiovascular disease associated with hormone replacement therapy using high-dose estrogen.

  5. Age influence on retention, distribution and internal doses of 85Sr in rat

    International Nuclear Information System (INIS)

    Tian Wuxun; Wang Decheng; Zhang Hongyuan

    1990-01-01

    After I.V. 85 Sr, the whole body 85 Sr-retentions in rats were fit to two compartment exponential equations. The equation parameters showed a significantly difference between the young group and both the adult and old groups (p 2 ) for 85 Sr in the slow compartment decreased in regular order from the young to the old groups. In the bone 85 Sr-retention equations Tb 2 of the slow compartment for 85 Sr in the young group was significantly lower than the adult and old groups. The doses of the whole body and red-marrow for young rats were 4.2 times as much as those of adult rats, and 6.2 and 5.9 times as much as those old rats. The dose-cumulative speeds was most quick in the young groups and similar in the adult and the old

  6. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, Georgina [Semmelweis Univ., Budapest (Hungary); Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary)

    2010-07-15

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D{sub min}) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D{sub r}) and urethra (D{sub u}), dose to volume of 2 cm{sup 3} of the rectum (D{sub 2ccm}), and 0.1 cm{sup 3} and 1% of the urethra (D{sub 0.1ccm} and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V{sub p}) was 27.1 cm{sup 3}. The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D{sub min} was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D{sub 2ccm} = 49% for the rectum, D{sub 0.1ccm} = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D{sub r}, D{sub 2ccm}) = 0.69, R(D{sub u}, D{sub 0.1ccm}) = 0.64, R(D{sub u}, D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose

  7. The effects of metformin on ovum implantation and pregnancy outcome in rats with induced PCOS

    Directory of Open Access Journals (Sweden)

    Mesbah F

    2011-06-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Polycystic ovary syndrome (PCOS is the most common cause of anovulatory infertility. Metformin which is effectively used for the treatment of anovulatory PCOS improves pregnancy rate and endometrial receptivity and reduces the risk of miscarriage. The aim of this study was to evaluate the effects of metformin on the endometrium, the number of fetuses and hormonal levels of PCOS rats."n"nMethods: Forty female adult Sprague-Dawley rats were assigned randomly into four equal groups. Group I: control rats, group II: rats receiving metformin (150 mg/kg/day, group III: Estradiol Valerate-induced PCOS rats (4 mg/rat and group IV: induced PCOS rats receiving metformin. Body weight and serum levels of glucose, LH, FSH, testosterone, progesterone and estradiol were measured. Following mating, each group was divided into two subgroups and the rats were sacrificed on the 5th and 15th day of gestation to evaluate endometrial reaction to implantation and fetus count, respectively."n"nResults: Hormone assay showed a significant increase in testosterone, estradiol, LH, FSH and blood glucose levels in group III compared to the controls (P≤0.01 and a significant decrease in blood glucose in group IV versus group III (P≤0

  8. Performance of rats orogastrically dosed with faecal strains of ...

    African Journals Online (AJOL)

    Administrator

    strains of Lactobacillus acidophilus and challenged ... Albino rats (Rattus norvegicus) were orogastrically dosed with faecal strains of Lactobacillus .... Chang et al. (2001) reported a similar observation in piglets fed probiotic strain, Lactobacillus reuteri BSA 131. Francisco et al. (1995) had earlier reported that selected ...

  9. Search for an anomalous near-surface yield deficit in Rutherford backscattering spectra from implanted germanium and silicon

    International Nuclear Information System (INIS)

    Lawson, E.M.; Appleton, B.R.

    1983-09-01

    Rutherford backscattering and channelling analysis of high-dose, room-temperature, ion-implanted germanium has revealed an anomalous near-surface yield deficit. Implant dose and species dependencies and the effect of annealing have been examined. A marked loss of implanted impurity was also noted. The yield deficit is attributed to the absorption of oxygen and other light mass contaminants into a highly porous implanted layer upon exposure to air. Loss of implant species is attributed to enhanced sputtering effects

  10. Implantation of β-emitters on biomedical implants: 32 P isotropic ion implantation using a coaxial plasma reactor

    International Nuclear Information System (INIS)

    Fortin, M.A.; Paynter, R.W.; Sarkissian, A.; Stansfield, B.L.; Terreault, B.; Dufresne, V.

    2003-01-01

    The development of endovascular brachytherapy and the treatment of certain types of cancers (liver, lung, prostate) often require the use of beta-emitters, sometimes in the form of radioisotope-implanted devices. Among the most commonly used isotopes figures 32 P, a pure beta-emitter (maximum energy: 1.7 MeV), of which the path in biological tissues is of a few cm, restricting the impact of electron bombardment to the immediate environment of the implant. Several techniques and processes have been tried to elaborate surfaces and devices showing strongly bonded, or implanted 32 P. Anodizing, vapor phase deposition, grafting of oligonucleotides, as well as ion implantation processes have been investigated by several research groups as methods to implant beta-radioisotopes into surfaces. A coaxial plasma reactor was developed at INRS to implant radioisotopes into cylindrical metallic objects, such as coronary stents commonly used in angioplasty procedures. The dispersion of 32 P atoms on the interior surfaces of the chamber can be investigated using radiographs, contributing to image the plasma ion transport mechanisms that guide the efficiency of the implantation procedure. The amount of radioactivity on the wall liner, on the internal components, and on the biomedical implants are quantified using a surface barrier detector. A comparative study establishes a relationship between the gray scale of the radiographs, and dose measurements. A program was developed to convert the digitized images into maps showing surface dose density in mCi/cm 2 . An integration process allows the quantification of the doses on the walls and components of the reactor. Finally, the resulting integral of the 32 P dose is correlated to the initial amount of radioactivity inserted inside the implanter before the dismantling procedure. This method could be introduced as a fast and reliable way to test, qualify and assess the amount of radioactivity present on the as-produced implants

  11. High-current and low acceleration voltage arsenic ion implanted polysilicon-gate and source-drain electrode Si mos transistor

    International Nuclear Information System (INIS)

    Saito, Yasuyuki; Sugimura, Yoshiro; Sugihara, Michiyuki

    1993-01-01

    The fabrication process of high current arsenic (As) ion implanted polysilicon (Si) gate and source drain (SD) electrode Si n-channel metal oxide-semiconductor field effect transistor (MOSFET) was examined. Poly Si film n-type doping was performed by using high current (typical current: 2mA) and relatively low acceleration voltage (40keV) As ion implantation technique (Lintott series 3). It was observed that high dose As implanted poly Si films as is show refractoriness against radical fluorine excited by microwave. Using GCA MANN4800 (m/c ID No.2, resist: OFPR) mask pattern printing technique, the high current As ion implantation technique and radical fluorine gas phase etching (Chemical dry etching: CDE) technique, the n-channel Poly Si gate (ρs = ≅100Ω/□) enhancement MQSFETs(ρs source drain = ≅50Ω/□, SiO 2 gate=380 angstrom) with off-leak-less were obtained on 3 inch Czochralski grown 2Ωcm boron doped p type wafers (Osaka titanium). By the same process, a 8 bit single chip μ-processor with 26MHz full operation was performed

  12. Acceleration of Medpor implant fibrovascularization with local vascular endothelial growth-factor injections: An experimental study

    Directory of Open Access Journals (Sweden)

    Mert Demirel

    2015-12-01

    Full Text Available Objective: Medpor is a biocompatible, high-density porous polyethylene implant that is used for multiple indications in plastic surgery. The most frequent complications associated with the Medpor implant are infection and implant exposure. The primary cause of these complications is poor fibrovascularization of the Medpor implant and poor nourishment of the overlying skin. The present experimental study aimed to determine whether vascular endothelial growth factor (VEGF could accelerate and increase Medpor implant fibrovascularization in vivo, and thereby improve local nourishment and prevent complications. Materials and Methods: The Medpor implant was inserted under the dorsal skin area in 40 Sprague-Dawley rats. 20 rats receiving local VEGF injections comprised the study group. The control group received saline injections. Fibrovascularization of the Medpor implants was compared. Results: In the rats injected with VEGF, the Medpor implant fibrovascularized faster, and there were more newly formed blood vessels, as compared with those in the control group. Conclusion: These findings have led to our use of VEGF-like agents that the accelerate angiogenesis in the Medpor implant as a means to reduce the incidence of such complications as infection and implant exposure. [Arch Clin Exp Surg 2015; 4(4.000: 196-201

  13. Absorbed and effective dose from spiral and computed tomography for the dental implant planning

    International Nuclear Information System (INIS)

    Hong, Beong Hee; Han, Won Jeong; Kim, Eun Kyung

    2001-01-01

    To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. For radiographic projection. TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophages. Effective dose was calculated, using the method suggested by Frederiksen at al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning

  14. Epithelial regeneration of transposed intestine after high doses of X irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Both, N.J. de; Vermey, M [Erasmus Universiteit, Rotterdam (Netherlands)

    1976-01-01

    The regeneration capacities of normal and transposed small bowel epithelium were compared in rats after applying high doses of x irradiation. It has been shown that the potency of the mucosa to regenerate was much higher than assumed and that the mucosa could regenerate after single doses varying from 2000 to 5000 R. Even in the villus epithelium and in flat epithelium covering infiltrates of the lamina propria cells survived, which were still able to resume proliferative activity several days after irradiation.

  15. Epithelial regeneration of transposed intestine after high doses of X-irradiation

    International Nuclear Information System (INIS)

    Both, N.J. de; Vermey, M.

    1976-01-01

    The regeneration capacities of normal and transposed small bowel epithelium were compared in rats after applying high doses of X-irradiation. It has been shown that the potency of the mucosa to regenerate was much higher than assumed and that the mucosa could regenerate after single doses varying from 2000 to 5000 R. Even in the villus epithelium and in flat epithelium covering infiltrates of the lamina propria cells survived, which were still able to resume proliferative activity several days after irradiation. (author)

  16. Histological analysis of low dose NMU effects in the rat mammary gland

    Directory of Open Access Journals (Sweden)

    Sonnenschein Carlos

    2009-08-01

    Full Text Available Abstract Background Our objective was to assess the histological changes in mammary glands of the female Wistar-Furth rat as a result of low dose exposure to N-nitrosomethylurea (NMU. Methods Groups of 30–40 virgin female rats of between 49–58 days old received a single injection of 10, 20, 30 or 50 mg NMU/kg body weight (BW. A group of 10 control rats received 0.9% NaCl solution only. The formation of palpable mammary gland tumors was assessed weekly and, upon sacrifice at 12, 22 and 25–30 weeks after treatment, we performed a comprehensive histological analysis of all mammary gland lesions and tumors. Results Alongside the predicted increase in tumor number and decrease in tumor latency with increasing NMU dose, we observed a number of microscopic lesions and other epithelial abnormalities in the mammary glands for all NMU doses. Two types of non-neoplastic histological changes were observed in rats exposed to 10 or 20 mg NMU/kg BW: namely, (i an increase in the number of acinar structures often accompanied by secretion into the lumen which is normally associated with pregnancy and lactation, and (ii an increase in the number of epithelial cells sloughed into the lumen of the epithelial ducts. Conclusion This study establishes a baseline for low-dose exposure and defines the histological features in the mammary gland resulting from NMU exposure. Furthermore, this system provides an ideal platform for evaluating the relative susceptibility of animals protected from, or predisposed to, developing cancer through environmental influences.

  17. SU-F-T-09: In Phantom Full-Implant Validation of Plastic Scintillation Detectors for in Vivo Dosimetry During Low Dose Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Therriault-Proulx, F; Bruno, T; Beddar, S [UT MD Anderson Cancer Center, Houston, TX (United States); Beaulieu, L [CHU de Quebec, Quebec, QC, CA (Canada)

    2016-06-15

    Purpose: To validate in a water phantom the use of plastic scintillation detectors to measure dose to the urethra and the rectal wall during a clinically realistic low dose rate (LDR) brachytherapy implant. Methods: A template was designed to replicate a clinically realistic LDR brachytherapy prostate implant inside a water phantom. Twenty-two catheters were inserted, including one mimicking the urethra and another the rectal wall. The needles inserted in the remaining 20 catheters were composed of thin-walled nylon tubes in which I-125 radioactive seeds (Air Kerma Strengths of (0.328±0.020)U) were abutted together with plastic spacers to replicate a typical loading. A plastic scintillation detector (PSD) with a 5-mm long × 1-mm diameter sensitive element was first placed inside the urethra and 1-second measurements were performed for 60s after each needle implant. Measurements were also performed at multiple positions along the urethra once all the needles were inserted. The procedure was then repeated with the PSD placed at the rectal wall. Results: Individual dose-rates ranging from 0.07µGy/s to 1.5µGy/s were measured after each needle implant. The average absolute relative differences were (6.2±3.6)% and (6.9±6.5)% to the values calculated with the TG-43 formalism, for the urethra and rectal wall respectively. These results are within expectations from the error uncertainty budget once accounting for uncertainties in seeds’ strength and positioning. Interestingly, the PSD allowed for unplanned error detection as the study was performed. Finally, the measured dose after the full implant at different positions along the mimicked organs at risk were in agreement with TG-43 values for all of the positions tested. Conclusion: Plastic scintillation detectors could be used as in vivo detectors for LDR brachytherapy as they would provide accurate dose information after each needle implant as well as along the organs at risk at the end of the implant.

  18. Neuron attachment properties of carbon negative-ion implanted bioabsorbable polymer of poly-lactic acid

    International Nuclear Information System (INIS)

    Tsuji, Hiroshi; Sasaki, Hitoshi; Sato, Hiroko; Gotoh, Yasuhito; Ishikawa, Junzo

    2002-01-01

    Modification of a bioabsorbable polymer of poly-lactic acid (PLA) by negative carbon ion implantation was investigated with resect to radiation effects on surface physical properties and nerve-cell attachment properties. Carbon negative ions were implanted to PLA at energy of 5-30 keV with a dose of 10 14 -10 16 ions/cm 2 . Most C-implanted PLA samples showed contact angles near 80 deg. and almost same as that of unimplanted PLA, although a few samples at 5 keV and less 3x10 14 ions/cm 2 had contact angles larger than 90 deg. The attachment properties of nerve cells of PC-12h (rat adrenal phechromocytoma) in vitro were studied. PC-12h cells attached on the unimplanted region in C-implanted PLA samples at 5 and 10 keV. On the contrary, the nerve cells attached on only implanted region for the C-implanted PLA sample at 30 keV and 1x10 15 ions/cm 2

  19. Lung tumors and radon inhalation in over 2000 rats: Approximate linearity across a wide range of doses and potentiation by tobacco smoke

    International Nuclear Information System (INIS)

    Gray, R.G.; Lafuma, J.; Parish, S.E.; Peto, R.; CEA Centre d'Etudes Nucleaires de Fontenay-aux-Roses

    1986-01-01

    More than 2000 rats were exposed to cumulative doses of up to 28,000 WLMs of radon gas. More than 300 pulmonary tumors were induced by this exposure, most being nonfatal lesions detected only at autopsy of animals that had died of unrelated causes. Above 6000 WLMs rats suffered increasingly from life shortening due to radiation-induced nonneoplastic causes and so had less time in which to develop tumors. When adjusted for these competing causes of death, the hazard function for the excess risk of developing pulmonary tumors was approximately linearly related to dose throughout the range of doses studied. This suggests that some previously reported high-dose ''reductions'' in radiogenic tumor-induction rates may chiefly have involved the killing of rats rather than the killing of precursor cells. Rats exposed to radon and then to six months of inhalation of tobacco smoke had a four times greater age-specific prevalence of pulmonary tumors than rats exposed to an identical radon dose either alone or preceded by tobacco smoke inhalation. This suggests that tobacco smoke may accelerate the carcinogenic process by acting as a promoter of radiation-induced somatic damage. These data suggest that, for assessing human risk from exposure to radon, the linear model should be assumed, but that the WLM is not on its own an adequate index of carcinogenic insult. 7 refs., 2 figs., 4 tabs

  20. No priming of the immune response in newborn Brown Norway rats dosed with ovalbumin in the mouth

    DEFF Research Database (Denmark)

    Madsen, Charlotte Bernhard; Pilegaard, Kirsten

    2003-01-01

    with ovalbumin and if this method could be used in an animal model for food allergy. Methods: Newborn Brown Norway rats were dosed with ovalbumin in the mouth (100 mug or 6 mg). As young adults, the animals were dosed by gavage for 35 days with 1 mg ovalbumin/day or once intraperitoneally with 100 mug. Control......E and IgG responses were decreased compared to the control groups, however, not always reaching statistical significance. A statistical significant decrease in the specific immune response was found in young adult rats dosed in the mouth as compared to by gavage. Conclusions: Dosing Brown Norway rats...

  1. Bone tissue engineering for spine fusion : An experimental study on ectopic and orthotopic implants in rats

    NARCIS (Netherlands)

    van Gaalen, SM; Dhert, WJA; van den Muysenberg, A; Oner, FC; van Blitterswijk, C; Verbout, AJ; de Bruijn, J.D.

    2004-01-01

    Alternatives to the use of autologous bone as a bone graft in spine surgery are needed. The purpose of this study was to examine tissue-engineered bone constructs in comparison with control scaffolds without cells in a posterior spinal implantation model in rats. Syngeneic bone marrow cells were

  2. Bile Salt Homeostasis in Normal and Bsep Gene Knockout Rats with Single and Repeated Doses of Troglitazone.

    Science.gov (United States)

    Cheng, Yaofeng; Chen, Shenjue; Freeden, Chris; Chen, Weiqi; Zhang, Yueping; Abraham, Pamela; Nelson, David M; Humphreys, W Griffith; Gan, Jinping; Lai, Yurong

    2017-09-01

    The interference of bile acid secretion through bile salt export pump (BSEP) inhibition is one of the mechanisms for troglitazone (TGZ)-induced hepatotoxicity. Here, we investigated the impact of single or repeated oral doses of TGZ (200 mg/kg/day, 7 days) on bile acid homoeostasis in wild-type (WT) and Bsep knockout (KO) rats. Following oral doses, plasma exposures of TGZ were not different between WT and KO rats, and were similar on day 1 and day 7. However, plasma exposures of the major metabolite, troglitazone sulfate (TS), in KO rats were 7.6- and 9.3-fold lower than in WT on day 1 and day 7, respectively, due to increased TS biliary excretion. With Bsep KO, the mRNA levels of multidrug resistance-associated protein 2 (Mrp2), Mrp3, Mrp4, Mdr1, breast cancer resistance protein (Bcrp), sodium taurocholate cotransporting polypeptide, small heterodimer partner, and Sult2A1 were significantly altered in KO rats. Following seven daily TGZ treatments, Cyp7A1 was significantly increased in both WT and KO rats. In the vehicle groups, plasma exposures of individual bile acids demonstrated variable changes in KO rats as compared with WT. WT rats dosed with TGZ showed an increase of many bile acid species in plasma on day 1, suggesting the inhibition of Bsep. Conversely, these changes returned to base levels on day 7. In KO rats, alterations of most bile acids were observed after seven doses of TGZ. Collectively, bile acid homeostasis in rats was regulated through bile acid synthesis and transport in response to Bsep deficiency and TGZ inhibition. Additionally, our study is the first to demonstrate that repeated TGZ doses can upregulate Cyp7A1 in rats. Copyright © 2017 by The American Society for Pharmacology and Experimental Therapeutics.

  3. Dose-dependent metabolic disposition of hydroxytyrosol and formation of mercapturates in rats.

    Science.gov (United States)

    Kotronoulas, Aristotelis; Pizarro, Nieves; Serra, Aida; Robledo, Patricia; Joglar, Jesús; Rubió, Laura; Hernaéz, Alvaro; Tormos, Carmen; Motilva, Ma José; Fitó, Montserrat; Covas, Maria-Isabel; Solà, Rosa; Farré, Magí; Saez, Guillermo; de la Torre, Rafael

    2013-11-01

    Hydroxytyrosol (HT), one of the major polyphenols present in olive oil, is known to possess a high antioxidant capacity. The aim of the present study was to investigate dose dependent (0, 1, 10 and 100 mg/kg) alterations in the metabolism of HT in rats since it has been reported that metabolites may contribute to biological effects. Special attention was paid to the activation of the semiquinone-quinone oxidative cycle and the formation of adducts with potential deleterious effects. Thus, we developed a novel analytical methodology to monitor the in vivo formation of the HT mercapturate, N-acetyl-5-S-cysteinyl-hydroxytyrosol in urine samples. Biomarkers of hepatic and renal toxicity were evaluated within the dose range tested. Following HT administration, dose-dependent effects were observed for the recovery of all the metabolites studied. At the lowest dose of 1 mg/kg, the glucuronidation pathway was the most relevant (25-30%), with lower recoveries for sulfation (14%), while at the highest dose of 100 mg/kg, sulfation was the most prevalent (75%). In addition, we report for the first time the formation of the mercapturate conjugate of HT in a dose-dependent manner. The biochemical data did not reveal significant toxic effects of HT at any of the doses studied. An increase in the GSH/GSSG ratio at the highest dose was observed indicating that the products of HT autoxidation are counteracted by glutathione, resulting in their detoxification. These results indicate that the metabolic disposition of HT is highly dependent on the dose ingested. Copyright © 2013. Published by Elsevier Ltd.

  4. Therapeutic interaction of systemically-administered mesenchymal stem cells with peri-implant mucosa.

    Directory of Open Access Journals (Sweden)

    Ryosuke Kondo

    Full Text Available OBJECTIVES: The objective of this study was to investigate the effect of systemically transplanted mesenchymal stem cells (MSCs on the peri-implant epithelial sealing around dental implants. MATERIALS AND METHODS: MSCs were isolated from bone marrow of donor rats and expanded in culture. After recipient rats received experimental titanium dental implants in the bone sockets after extraction of maxillary right first molars, donor rat MSCs were intravenously transplanted into the recipient rats. RESULTS: The injected MSCs were found in the oral mucosa surrounding the dental implants at 24 hours post-transplantation. MSC transplantation accelerated the formation of the peri-implant epithelium (PIE-mediated mucosa sealing around the implants at an early stage after implantation. Subsequently, enhanced deposition of laminin-332 was found along the PIE-implant interface at 4 weeks after the replacement. We also observed enhanced attachment and proliferation of oral mucous epithelial cells. CONCLUSION: Systemically transplanted MSCs might play a critical role in reinforcing the epithelial sealing around dental implants.

  5. The effect of metallic implants on radiation therapy in spinal tumor patients with metallic spinal implants.

    Science.gov (United States)

    Son, Seok Hyun; Kang, Young Nam; Ryu, Mi-Ryeong

    2012-01-01

    The aim of this study was to evaluate the effect of metallic implants on the dose calculation for radiation therapy in patients with metallic implants and to find a way to reduce the error of dose calculation. We made a phantom in which titanium implants were inserted into positions similar to the implant positions in spinal posterior/posterolateral fusion. We compared the calculated dose of the treatment planning systems with the measured dose in the treatment equipment. We used 3 kinds of computed tomography (CT) (kilovoltage CT, extended-scaled kilovoltage CT, and megavoltage CT) and 3 kinds of treatment equipment (ARTISTE, TomoTherapy Hi-Art, and Cyberknife). For measurement of doses, we used an ionization chamber and Gafchromic external beam therapy film. The absolute doses that were measured using an ionization chamber at the isocenter in the titanium phantom were on average 1.9% lower than those in the reference phantom (p = 0.002). There was no statistically significant difference according to the kinds of CT images, the treatment equipment, and the size of the targets. As the distance from the surface of the titanium implants became closer, the measured doses tended to decrease (p metallic implants was less in the megavoltage CT than in the kilovoltage CT or the extended-scaled kilovoltage CT. The error caused by the titanium implants was beyond a clinically acceptable range. To reduce the error of dose calculation, we suggest that the megavoltage CT be used for planning. In addition, it is necessary to consider the distance between the titanium implants and the targets or the organs at risk to prescribe the dose for the target and the dose constraint for the organs at risk. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  6. The effect of dose, dose rate, route of administration, and species on tissue and blood levels of benzene metabolites

    International Nuclear Information System (INIS)

    Henderson, R.F.; Sabourin, P.J.; Bechtold, W.E.; Griffith, W.C.; Medinsky, M.A.; Birnbaum, L.S.; Lucier, G.W.

    1989-01-01

    Studies were completed in F344/N rats and B6C3F 1 mice to determine the effect of dose, dose rate, route of administration, and rodent species on formation of total and individual benzene metabolites. Oral doses of 50 mg/kg or higher saturated the capacity for benzene metabolism in both rats and mice, resulting in an increased proportion of the administered dose being exhaled as benzene. The saturating air concentration for benzene metabolism during 6-hr exposures was between 130 and 900 ppm. At the highest exposure concentration, rats exhaled approximately half of the internal dose retained at the end of the 6-hr exposure as benzene; mice exhaled only 15% as benzene. Mice were able to convert more of the inhaled benzene to metabolites than were rats. In addition, mice metabolized more of the benzene by pathways leading to the putative toxic metabolites, benzoquinone and muconaldehyde, than did rats. In both rats and mice, the effect of increasing dose, administered orally or by inhalation, was to increase the proportion of the total metabolites that were the products of detoxification pathways relative to the products of pathways leading to putative toxic metabolites. This indicates low-affinity, high-capacity pathways for detoxification and high-affinity, low-capacity pathways leading to putative toxic metabolites. If the results of rodent studied performed at high doses were used to assess the health risk at low-dose exposures to benzene, the toxicity of benzene would be underestimated

  7. Study on a 4-Week Recovery Test of Sweet Bee Venom after a 13-Week, Repeated, Intramuscular Dose Toxicity Test in Sprague-Dawley Rats

    Directory of Open Access Journals (Sweden)

    Chungsan Lim

    2014-06-01

    Full Text Available Objectives:This study was performed to check for reversibility in the changes induced by a 13-week, repeated, dose toxicity test of Sweet Bee Venom (SBV in Sprague-Dawley (SD rats. Methods:Fifteen male and 15 female SD rats were treated with 0.28 mg/kg of SBV (high-dosage group and the same numbers of male and female SD rats were treated with 0.2 mL/kg of normal saline (control group for 13 weeks. We selected five male and five female SD rats from the high-dosage group and the same numbers of male and female SD rats from the control group, and we observed these rats for four weeks. We conducted body-weight measurements, ophthalmic examinations, urinalyses and hematology, biochemistry, histology tests. Results:(1 Hyperemia and movement disorder were observed in the 13-week, repeated, dose toxicity test, but these symptoms were not observed during the recovery period. (2 The rats in the high-dose group showed no significant changes in weight compared to the control group. (3 No significant differences in the ophthalmic parameters, urine analyses, complete blood cell counts (CBCs, and biochemistry were observed among the recovery groups. (4 No changes in organ weights were observed during the recovery period. (5 Histological examination of the thigh muscle indicated cell infiltration, inflammation, degeneration, necrosis of muscle fiber, and fibrosis during the treatment period, but these changes were not observed during the recovery period. The fatty liver change that was observed during the toxicity test was not observed during the recovery period. No other organ abnormalities were observed. Conclusion:The changes that occurred during the 13-week, repeated, dose toxicity test are reversible, and SBV can be safely used as a treatment modality.

  8. Annealing of ion implanted silicon

    International Nuclear Information System (INIS)

    Chivers, D.; Smith, B.J.; Stephen, J.; Fisher, M.

    1980-09-01

    The newer uses of ion implantation require a higher dose rate. This has led to the introduction of high beam current implanters; the wafers move in front of a stationary beam to give a scanning effect. This can lead to non-uniform heating of the wafer. Variations in the sheet resistance of the layers can be very non-uniform following thermal annealing. Non-uniformity in the effective doping both over a single wafer and from one wafer to another, can affect the usefulness of ion implantation in high dose rate applications. Experiments to determine the extent of non-uniformity in sheet resistance, and to see if it is correlated to the annealing scheme have been carried out. Details of the implantation parameters are given. It was found that best results were obtained when layers were annealed at the maximum possible temperature. For arsenic, phosphorus and antimony layers, improvements were observed up to 1200 0 C and boron up to 950 0 C. Usually, it is best to heat the layer directly to the maximum temperature to produce the most uniform layer; with phosphorus layers however it is better to pre-heat to 1050 0 C. (U.K.)

  9. Ellipsometric and channeling studies on ion-implanted silicon

    International Nuclear Information System (INIS)

    Lohner, T.; Mezey, G.; Kotai, E.; Paszti, F.; Kiralyhidi, L.; Valyi, G.; Gyulai, J.

    1980-09-01

    RBS and ellipsometric investigations were combined to separate the contribution of radiation damage and overlayer contamination. It is pointed out that disorder effects which were produced by silicon self-implantation are shielded without proper surface cleaning. For cleaning, plasma stripping proved to be an effective method. The change in psi parameter could be correlated with the degree of amorphousness. It seems that Δ parameter ''feels'' crystalline-amorphous phase transition on low dose 31 P + and 27 Al + implants. No clear evidence was found for impurity effects on high-dose 75 As + and 31 P + implants. (author)

  10. Micro-cutting of silicon implanted with hydrogen and post-implantation thermal treatment

    Science.gov (United States)

    Jelenković, Emil V.; To, Suet; Sundaravel, B.; Xiao, Gaobo; Huang, Hu

    2016-07-01

    It was reported that non-amorphizing implantation by hydrogen has a potential in improving silicon machining. Post-implantation high-temperature treatment will affect implantation-induced damage, which can have impact on silicon machining. In this article, a relation of a thermal annealing of hydrogen implanted in silicon to micro-cutting experiment is investigated. Hydrogen ions were implanted into 4″ silicon wafers with 175 keV, 150 keV, 125 keV and doses of 2 × 1016 cm-2, 2 × 1016 cm-2 and 3 × 1016 cm-2, respectively. In this way, low hydrogen atom-low defect concentration was created in the region less than ~0.8 μm deep and high hydrogen atom-high defect concentration was obtained at silicon depth of ~0.8-1.5 μm. The post-implantation annealing was carried out at 300 and 400 °C in nitrogen for 1 h. Physical and electrical properties of implanted and annealed samples were characterized by secondary ion mass spectroscopy (SIMS), X-ray diffraction (XRD), Rutherford backscattering (RBS) and nanoindentation. Plunge cutting experiment was carried out in and silicon crystal direction. The critical depth of cut and cutting force were monitored and found to be influenced by the annealing. The limits of hydrogen implantation annealing contribution to the cutting characteristics of silicon are discussed in light of implantation process and redistribution of hydrogen and defects generation during annealing process.

  11. Screening of a lactobacillus plantarum mutant with high cla productivity induced by n+ implantation

    International Nuclear Information System (INIS)

    Li Shurong; Meng Xianjun; Zhang Tao; Zhao Hongwei; Lu Jiaping; Zhao Yun; Gao Yanhong; Li Qingpeng

    2009-01-01

    The initial lactic acid bacteria strain A6-1 was treated by N + ions implantation of 50 keV with doses of 1 x 10 13 , 3 x 10 13 , 5 x 10 13 , 8 x 10 13 , 10 x 10 13 , 30 x 10 13 , 50 x 10 13 , 80 x 10 13 , and 100 x 10 13 ions/cm 2 . The survival curve showed a saddle model, and the high survival rate was 20% ∼ 35% from the treatments of 30 x 10 13 ions/cm 2 and 50 x 10 13 ions/cm 2 implantation. Considering the survival rate, positive mutation and range of mutation rate, N + ions implantation of 30 x 10 13 ions/cm 2 was recommended for mutation breeding of lactic acid bacteria. Selected mutants with high ability of producing CLA after fermentation. Generic stable was observed until 8 generations of F mutant, and average yield of CLA was 162.5 μg/ml, which was 69.87% higher than the original stain. F mutant was named A6-1F. (authors)

  12. Architecture and control of a high current ion implanter system

    International Nuclear Information System (INIS)

    Bayer, E.H.; Paul, L.F.; Kranik, J.R.

    1979-01-01

    The design of an ion implant system for use in production requires that special attention be given to areas of design which normally are not emphasized on research or development type ion implanters. Manually operated, local controls are replaced by remote controls, automatic sequencing, and digital displays. For ease of maintenance and replication the individual components are designed as simply as possible and are contained in modules of separate identities, joined only by the beam line and electrical interconnections. A production environment also imposes requirements for the control of contamination and maintainability of clean room integrity. For that reason the major portion of the hardware is separated from the clean operator area and is housed in a maintenance core area. The controls of a production system should also be such that relatively unskilled technicians are able to operate the system with optimum repeatability and minimum operator intervention. An extensive interlock system is required. Most important, for use in production the ion implant system has to have a relatively high rate of throughput. Since the rate of throughput at a given dose is a function of beam current, pumpdown time and wafer handling capacity, design of components affecting these parameters has been optimized. Details of the system are given. (U.K.)

  13. Pharmacokinetic interaction of enrofloxacin/trimethoprim combination following single-dose intraperitoneal and oral administration in rats.

    Science.gov (United States)

    Choi, Myung-Jin; Yohannes, Sileshi Belew; Lee, Seung-Jin; Damte, Dereje; Kim, Jong-Choon; Suh, Joo-Won; Park, Seung-Chun

    2014-03-01

    The pharmacokinetic interaction of enrofloxacin and trimethoprim was evaluated after single-dose intraperitoneal or oral co-administration in rats. Plasma concentrations of the two drugs were determined by high-performance liquid chromatography. Following intraperitoneal combination, a significant (P trimethoprim, respectively. There was a significant (P trimethoprim. Further study is recommended in other species of animals.

  14. The effect of dexamethasone on the uptake of p-boronophenylalanine in the rat brain and intracranial 9L gliosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Morris, G.M.; Micca, P.L.; Coderre, J.A. E-mail: coderre@mit.edu

    2004-11-01

    The steroid dexamethasone sodium phosphate (DEX) is routinely used to treat edema in brain tumor patients. The objective of the present study was to evaluate the effects of DEX on the uptake of boronophenylalanine (BPA) using the rat 9L gliosarcoma tumor model and surrounding brain tissue. Two steroid dosage protocols were used. The high-dose DEX protocol involved five 3 mg/kg intraperitoneal injections at 47, 35, 23, 11 and 1 h prior to the administration of the BPA for a total dose of 15 mg DEX/kg rat. The low-dose DEX administration protocol involved two doses of 1.5 mg/kg at 17 h and 1 h prior to BPA injection for a total dose of 3 mg DEX/kg rat. The control animals received no pretreatment, prior to the administration of BPA. Seventeen days after tumor implantation, rats were injected i.p. with 0.014 ml/g body weight BPA solution (1200 mg BPA/kg; {approx}59 mg {sup 10}B/kg). In all groups, rats were euthanized at 3 h after BPA injection. Administration of the steroid had an effect on tumor weight, which decreased to {approx}78% (p>0.05) of the control weight in the low-dose DEX group, and {approx}48% (p<0.001) of the control weight in the high-dose DEX group. At 3 h after the administration of BPA, the concentration of boron in tumor was comparable (p>0.1) in the control and high-dose DEX groups. The lowest mean value (73.8{+-}1.6 {mu}g/g) was obtained in the low-dose DEX group. This was significantly lower (p>0.02) than the tumor boron contents in the high-dose DEX and control groups, which were 81.1{+-}1.9 and 79.9{+-}1.7 {mu}g/g, respectively. Tumor:blood boron partition ratios for the control, low- and high-dose DEX groups were 2.3, 2.3 and 2.5, respectively. Boron concentrations were also measured in the normal brain and in the zone of brain adjacent to the tumor exhibiting edema. Although treatment with DEX had no appreciable effect on boron uptake in the normal brain of the rat, after the administration of BPA, it did impact on the boron levels in the

  15. Members of the WA9 team celebrate

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    WA9 was an experiment set up by the Clermont Ferrand-Leningrad-Lyon-Uppsala Collaboration to study with high precision elastic scattering in the Coulomb interference region. Here: A.A. Vorobyov, M. Querrou, A.P. Kashchuk, I.I. Tkach, J.P. Martin, T. Ekelöf, G.A. Korolev, (?), V.A. Schegelsky, A.S. Denisov, S. Kullander, M. Chemarin, P. Grafström, S. Maury, E. Hagberg

  16. Effect of annealing on photoluminescence properties of neon implanted GaN

    Energy Technology Data Exchange (ETDEWEB)

    Majid, Abdul [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Ali, Akbar [Advance Materials Physics Laboratory, Physics Department, Quaid-i-Azam University, Islamabad (Pakistan); Zhu, J J [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Wang, Y T [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Liu, W [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Lu, G J [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Liu, W B [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Zhang, L Q [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Liu, Z S [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Zhao, D G [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Zhang, S M [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Jiang, D S; Yang, H [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China)

    2008-01-21

    The effect of thermal annealing on the luminescence properties of neon implanted GaN thin films was studied. Low temperature photoluminescence (PL) measurements were carried out on the samples implanted with different doses ranging from 10{sup 14} to 9 x 10{sup 15} cm{sup -2} and annealed isochronally at 800 and 900 deg. C. We observed a new peak appearing at 3.44 eV in the low temperative PL spectra of all the implanted samples after annealing at 900 deg. C. This peak has not been observed in the PL spectra of implanted samples annealed at 800 deg. C except for the samples implanted with the highest dose. The intensity of the yellow luminescence (YL) band noticed in the PL spectra measured after annealing was observed to decrease with the increase in dose until it was completely suppressed at a dose of 5 x 10{sup 15} cm{sup -2}. The appearance of a new peak at 3.44 eV and dose dependent suppression of the YL band are attributed to the dissociation of V{sub Ga}O{sub N} complexes caused by high energy ion implantation.

  17. Effect of annealing on photoluminescence properties of neon implanted GaN

    International Nuclear Information System (INIS)

    Majid, Abdul; Ali, Akbar; Zhu, J J; Wang, Y T; Liu, W; Lu, G J; Liu, W B; Zhang, L Q; Liu, Z S; Zhao, D G; Zhang, S M; Jiang, D S; Yang, H

    2008-01-01

    The effect of thermal annealing on the luminescence properties of neon implanted GaN thin films was studied. Low temperature photoluminescence (PL) measurements were carried out on the samples implanted with different doses ranging from 10 14 to 9 x 10 15 cm -2 and annealed isochronally at 800 and 900 deg. C. We observed a new peak appearing at 3.44 eV in the low temperative PL spectra of all the implanted samples after annealing at 900 deg. C. This peak has not been observed in the PL spectra of implanted samples annealed at 800 deg. C except for the samples implanted with the highest dose. The intensity of the yellow luminescence (YL) band noticed in the PL spectra measured after annealing was observed to decrease with the increase in dose until it was completely suppressed at a dose of 5 x 10 15 cm -2 . The appearance of a new peak at 3.44 eV and dose dependent suppression of the YL band are attributed to the dissociation of V Ga O N complexes caused by high energy ion implantation

  18. Beneficial effects of low dose Musa paradisiaca on the semen quality of male Wistar rats.

    Science.gov (United States)

    Alabi, A S; Omotoso, Gabriel O; Enaibe, B U; Akinola, O B; Tagoe, C N B

    2013-03-01

    This study aimed at determining the effects of administration of mature green fruits of Musa paradisiaca on the semen quality of adult male Wistar rats. THE ANIMALS USED FOR THE STUDY WERE GROUPED INTO THREE: the control group, given 2 ml of double distilled water, a low dose group given 500 mg/kg/day and a high dose group given 1000 mg/kg/day of the plantain fruits, which was made into flour, and dissolved in 2 ml of double distilled water for easy oral administration. Significant increment in the semen parameters was noticed in animals that received a lower dose of the plantain flour, but those animals who received the high dose had marked and very significant reduction in sperm cell concentration and percentage of morphologically normal spermatozoa. Musa paradisiaca should be consumed in moderate quantities in order to derive its beneficial effects of enhancing male reproductive functions.

  19. Martensitic transformation in helium implanted 316 stainless steel

    International Nuclear Information System (INIS)

    Ishimatsu, Manabu; Tsukuda, Noboru

    1997-01-01

    In order to simulate surface deterioration phenomenon due to particle loading of SUS-316 steel which is one of candidate materials for nuclear fusion reactor vacuum wall structure material, helium ion implanting was conducted at room temperature, 473 K and 573 K. To martensitic phase formed as a results, implantation dose dependence, implanting temperature dependence, and annealing under 1073 K were conducted. Formation of the martensitic phase was suppressed at high implanting temperature. At room temperature implantation, the martensitic phase disappeared at more than 873 K, but at high temperature implantation, it increased abnormally near at 973 K. This showed that deterioration of materials depended extremely upon using temperature and temperature history. (G.K.)

  20. Dynamics of rectal balloon implant shrinkage in prostate VMAT. Influence on anorectal dose and late rectal complication risk

    International Nuclear Information System (INIS)

    Vanneste, Ben G.L.; Wijk, Y. van; Lutgens, L.C.; Limbergen, E.J. van; Lambin, P.; Lin, E.N. van; Beek, K. van de; Hoffmann, A.L.

    2018-01-01

    To assess the effect of a shrinking rectal balloon implant (RBI) on the anorectal dose and complication risk during the course of moderately hypofractionated prostate radiotherapy. In 15 patients with localized prostate cancer, an RBI was implanted. A weekly kilovolt cone-beam computed tomography (CBCT) scan was acquired to measure the dynamics of RBI volume and prostate-rectum separation. The absolute anorectal volume encompassed by the 2 Gy equieffective 75 Gy isodose (V 75Gy ) was recalculated as well as the mean anorectal dose. The increase in estimated risk of grade 2-3 late rectal bleeding (LRB) between the start and end of treatment was predicted using nomograms. The observed acute and late toxicities were evaluated. A significant shrinkage of RBI volumes was observed, with an average volume of 70.4% of baseline at the end of the treatment. Although the prostate-rectum separation significantly decreased over time, it remained at least 1 cm. No significant increase in V 75Gy of the anorectum was observed, except in one patient whose RBI had completely deflated in the third week of treatment. No correlation between mean anorectal dose and balloon deflation was found. The increase in predicted LRB risk was not significant, except in the one patient whose RBI completely deflated. The observed toxicities confirmed these findings. Despite significant decrease in RBI volume the high-dose rectal volume and the predicted LRB risk were unaffected due to a persistent spacing between the prostate and the anterior rectal wall. (orig.) [de

  1. SIMS analyses of ultra-low-energy B ion implants in Si: Evaluation of profile shape and dose accuracy

    International Nuclear Information System (INIS)

    Magee, C.W.; Hockett, R.S.; Bueyueklimanli, T.H.; Abdelrehim, I.; Marino, J.W.

    2007-01-01

    Numerous experimental studies for near-surface analyses of B in Si have shown that the B distribution within the top few nanometers is distorted by secondary ion mass spectrometry (SIMS) depth profiling with O 2 -flooding or normal incidence O 2 bombardment. Furthermore, the presence of surface oxide affects the X j determination as well as B profile shape when SIMS analyses are conducted while fully oxidizing the analytical area. Nuclear techniques such as elastic recoil detection (ERD), nuclear reaction analysis (NRA), and high-resolution Rutherford backscattering spectrometry (HR-RBS), are known to provide a profile shape near the surface that is free of artifacts. Comparisons with SIMS analyses have shown that SIMS analyses without fully oxidizing the analytical area agree well with these techniques at sufficiently high concentrations (where the nuclear techniques are applicable). The ability to measure both the B profile and an oxide marker with this non-oxidizing SIMS technique also allows accurate positioning of the B profile with respect to the SiO 2 /Si interface. This SIMS analysis protocol has been used to study the differences in near-surface dopant distribution for plasma-based implants. This study specifically focuses on measuring near-surface profile shapes as well as total implant doses for ultra-shallow B implants in Si especially those made with high peak B concentrations

  2. Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

    International Nuclear Information System (INIS)

    Scalchi, Paolo; Righetto, Roberto; Cavedon, Carlo; Francescon, Paolo; Colombo, Federico

    2010-01-01

    Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of

  3. SU-E-T-274: Radiation Therapy with Very High-Energy Electron (VHEE) Beams in the Presence of Metal Implants

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, C; Palma, B; Qu, B; Maxim, P; Loo, B; Bazalova, M [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Hardemark, B; Hynning, E [RaySearch Laboratories, Stockholm (Sweden)

    2014-06-01

    Purpose: To evaluate the effect of metal implants on treatment plans for radiation therapy with very high-energy electron (VHEE) beams. Methods: The DOSXYZnrc/BEAMnrc Monte Carlo (MC) codes were used to simulate 50–150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of thicknesses ranging from 0.5cm to 2cm were placed at 10cm depth. MC was also used to calculate electron and photon spectra generated by the VHEE beams' interaction with metal heterogeneities. The original VMAT patient dose calculation was planned in Eclipse. Patient dose calculations with MC-generated beamlets were planned using a Matlab GUI and research version of RayStation. VHEE MC treatment planning was performed on water-only geometry and water with segmented prostheses (steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel/Ti heterogeneity was 51% less than in the water-only phantom. For some cases, dose enhancement lateral to the borders of the phantom increased the dose by up to 22% in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the steel heterogeneity created a 23% increase in dose directly behind it. The average dose immediately behind Ti heterogeneities increased 10%. The prostate VHEE plans resulted in mean dose decrease to the bowel (20%), bladder (7%), and the urethra (5%) compared to the 15MV VMAT plan. The average dose to the body with prosthetic implants was 5% higher than to the body without implants. Conclusion: Based on MC simulations, metallic implants introduce dose perturbations to VHEE beams from lateral scatter and backscatter. However, when performing clinical planning on a prostate case, the use of multiple beams and inverse planning still produces VHEE plans that are dosimetrically superior to photon VMAT plans. BW Loo and P Maxim received research support from

  4. SU-E-T-274: Radiation Therapy with Very High-Energy Electron (VHEE) Beams in the Presence of Metal Implants

    International Nuclear Information System (INIS)

    Jensen, C; Palma, B; Qu, B; Maxim, P; Loo, B; Bazalova, M; Hardemark, B; Hynning, E

    2014-01-01

    Purpose: To evaluate the effect of metal implants on treatment plans for radiation therapy with very high-energy electron (VHEE) beams. Methods: The DOSXYZnrc/BEAMnrc Monte Carlo (MC) codes were used to simulate 50–150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of thicknesses ranging from 0.5cm to 2cm were placed at 10cm depth. MC was also used to calculate electron and photon spectra generated by the VHEE beams' interaction with metal heterogeneities. The original VMAT patient dose calculation was planned in Eclipse. Patient dose calculations with MC-generated beamlets were planned using a Matlab GUI and research version of RayStation. VHEE MC treatment planning was performed on water-only geometry and water with segmented prostheses (steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel/Ti heterogeneity was 51% less than in the water-only phantom. For some cases, dose enhancement lateral to the borders of the phantom increased the dose by up to 22% in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the steel heterogeneity created a 23% increase in dose directly behind it. The average dose immediately behind Ti heterogeneities increased 10%. The prostate VHEE plans resulted in mean dose decrease to the bowel (20%), bladder (7%), and the urethra (5%) compared to the 15MV VMAT plan. The average dose to the body with prosthetic implants was 5% higher than to the body without implants. Conclusion: Based on MC simulations, metallic implants introduce dose perturbations to VHEE beams from lateral scatter and backscatter. However, when performing clinical planning on a prostate case, the use of multiple beams and inverse planning still produces VHEE plans that are dosimetrically superior to photon VMAT plans. BW Loo and P Maxim received research support from

  5. Impact of dental implant insertion method on the peri-implant bone tissue: Experimental study

    Directory of Open Access Journals (Sweden)

    Stamatović Novak

    2013-01-01

    Full Text Available Background/Aim. The function of dental implants depends on their stability in bone tissue over extended period of time, i.e. on osseointegration. The process through which osseointegration is achieved depends on several factors, surgical insertion method being one of them. The aim of this study was to histopathologically compare the impact of the surgical method of implant insertion on the peri-implant bone tissue. Methods. The experiment was performed on 9 dogs. Eight weeks following the extraction of lower premolars implants were inserted using the one-stage method on the right mandibular side and two-stage method on the left side. Three months after implantation the animals were sacrificed. Three distinct regions of bone tissue were histopathologically analyzed, the results were scored and compared. Results. In the specimens of one-stage implants increased amount of collagen fibers was found in 5 specimens where tissue necrosis was also observed. Only moderate osteoblastic activity was found in 3 sections. The analysis of bone-to-implant contact region revealed statistically significantly better results regarding the amount of collagen tissue fibers for the implants inserted in the two-stage method (Wa = 59 105, α = 0.05. No necrosis and osteoblastic activity were observed. Conclusion. Better results were achieved by the two-stage method in bone-to-implant contact region regarding the amount of collagen tissue, while the results were identical regarding the osteoblastic activity and bone tissue necrosis. There was no difference between the methods in the bone-implant interface region. In the bone tissue adjacent to the implant the results were identical regarding the amount of collagen tissue, osteoblastic reaction and bone tissue necrosis, while better results were achieved by the two-stage method regarding the number of osteocytes.

  6. Long-term neuroplasticity of the face primary motor cortex and adjacent somatosensory cortex induced by tooth loss can be reversed following dental implant replacement in rats.

    Science.gov (United States)

    Avivi-Arber, Limor; Lee, Jye-Chang; Sood, Mandeep; Lakschevitz, Flavia; Fung, Michelle; Barashi-Gozal, Maayan; Glogauer, Michael; Sessle, Barry J

    2015-11-01

    Tooth loss is common, and exploring the neuroplastic capacity of the face primary motor cortex (face-M1) and adjacent primary somatosensory cortex (face-S1) is crucial for understanding how subjects adapt to tooth loss and their prosthetic replacement. The aim was to test if functional reorganization of jaw and tongue motor representations in the rat face-M1 and face-S1 occurs following tooth extraction, and if subsequent dental implant placement can reverse this neuroplasticity. Rats (n = 22) had the right maxillary molar teeth extracted under local and general anesthesia. One month later, seven rats had dental implant placement into healed extraction sites. Naive rats (n = 8) received no surgical treatment. Intracortical microstimulation (ICMS) and recording of evoked jaw and tongue electromyographic responses were used to define jaw and tongue motor representations at 1 month (n = 8) or 2 months (n = 7) postextraction, 1 month postimplant placement, and at 1-2 months in naive rats. There were no significant differences across study groups in the onset latencies of the ICMS-evoked responses (P > 0.05), but in comparison with naive rats, tooth extraction caused a significant (P rats. These novel findings suggest that face-M1 and adjacent face-S1 may play a role in adaptive mechanisms related to tooth loss and their replacement with dental implants. © 2015 Wiley Periodicals, Inc.

  7. The effects of rat's sperm bioassay for low dose X-ray

    International Nuclear Information System (INIS)

    Jin, Gye Hwan; Min, Soo Young; Lee, Sang Bock; Lee, Sam Yul; Lee, Jun Haeng; Park, Jong Bae

    2007-01-01

    In order to investigate the enhancement effects of low dose radiation on biological activation, this study applied low dose X-ray to the whole body of male rats to find out whether hormesis is induced in male germ cells. Total 36 Sprague-Dawley (SD) rats as experimental animal were subdivided into 6 groups(in 6 rats per group) such as control, 10 mGy, 20 mGy, 50 mGy, 100 mGy and 200 mGy radiation group. All the groups showed slightly increasing number of sperms per 0.1 g semen (14.216 x 10 6 , 13.901 x 10 6 , 14.153 x 10 6 , 13.831 x 10 6 , 14.137 x 10 6 , 14.677 x 10 6 respectively), and the motility of sperms amounted to 50.9%, 49.5%, 55.1%, 54.3%, 48.0% and 52.2% respectively. Particularly, compared to the control, the other 5 groups showed higher male hormone level, and the microscopic observations of testicle tissues showed no vacuolization in seminiferous tubules and testis cells. In the results of this experiment, no harmful effect was observed on Sprague-Dawley (SD) rats for which the dose of radiation was controlled as regulated legally by the Ministry of Science and Technology and the Ministry of Health and Welfare. However, as these results were obtained from a limited number of animals, we cannot maintain that the same effect will be observed in the human body. Therefore, there should be further research on the effect on other animals and ultimately on the human body

  8. Influence of Piezosurgery on Bone Healing around Titanium Implants: A Histological Study in Rats.

    Science.gov (United States)

    Sirolli, Marcelo; Mafra, Carlos Eduardo Secco; Santos, Rodrigo Albuquerque Basílio Dos; Saraiva, Luciana; Holzhausen, Marinella; César, João Batista

    2016-01-01

    The aim of this study was to evaluate histomorphometrically the influence of two techniques of dental implant site preparation on bone healing around titanium implants. Fifteen male Wistar rats (±300 g) were used in the study. Each tibia was randomly assigned to receive the implant site preparation either with a conventional drilling technique (control - DRILL group) or with a piezoelectric device (PIEZO group). The animals were sacrificed after 30 days and then the following histomorphometric parameters were evaluated (percentage) separately for cortical and cancellous regions: proportion of mineralized tissue (PMT) adjacent to implant threads (500 μm adjacent); bone area within the threads (BA) and bone-implant contact (BIC). The results demonstrated that there were no statistically significant differences between both groups for cancellous BIC (p>0.05) and cortical PMT (p>0.05). On the other hand, a higher percentage of BA was observed in the PIEZO group in the cortical (71.50±6.91 and 78.28±4.38 for DRILL and PIEZO groups, respectively; ppiezosurgery also showed higher PMT values in the cancellous zone (9.35±5.54 and 18.72±13.21 for DRILL and PIEZO groups, respectively; ppiezosurgery was beneficial to bone healing rates in the cancellous bone region, while the drill technique produced better results in the cortical bone.

  9. A Mutant of Bacillus Subtilis with High-Producing Surfactin by Ion Beam Implantation

    International Nuclear Information System (INIS)

    Liu Qingmei; Yuan Hang; Wang Jun; Gong Guohong; Zhou Wei; Fan Yonghong; Wang Li; Yao Jianming; Yu Zengliang

    2006-01-01

    In order to generate a mutant of Bacillus subtilis with enhanced surface activity through low energy nitrogen ion beam implantation, the effects of energy and dose of ions implanted were studied. The morphological changes in the bacteria were observed by scanning electron microscope (SEM). The optimum condition of ions implantation, 20 keV of energy and 2.6x10 15 N + /cm 2 in dose, was determined. A mutant, B.s-E-8 was obtained, whose surface activity of 50-fold and 100-fold diluted cell-free Landy medium was as 5.6-fold and 17.4-fold as the wild strain. The microbial growth and biosurfactant production of both the mutant and the wild strain were compared. After purified by ultrafiltration and SOURCE 15PHE, the biosurfactant was determined to be a complex of surfactin family through analysis of electrospray ionization mass spectrum (ESI/MS) and there was an interesting finding that after the ion beam implantation the intensities of the components were different from the wild type strain

  10. Responses of rat R-1 cells to low dose rate gamma radiation and multiple daily dose fractions

    International Nuclear Information System (INIS)

    Kal, H.B.; Bijman, J.Th.

    1981-01-01

    Multifraction irradiation may offer the same therapeutic gain as continuous irradiation. Therefore, a comparison of the efficacy of low dose rate irradiation and multifraction irradiation was the main objective of the experiments to be described. Both regimens were tested on rat rhabdomyosarcoma (R-1) cells in vitro and in vivo. Exponentially growing R-1 cells were treated in vitro by a multifraction irradiation procedure with dose fractions of 2 Gy gamma radiation and time intervals of 1 to 3 h. The dose rate was 1.3 Gy.min -1 . The results indicate that multifractionation of the total dose is more effective with respect to cell inactivation than continuous irradiation. (Auth.)

  11. Effects of mechanical repetitive load on bone quality around implants in rat maxillae.

    Directory of Open Access Journals (Sweden)

    Yusuke Uto

    Full Text Available Greater understanding and acceptance of the new concept "bone quality", which was proposed by the National Institutes of Health and is based on bone cells and collagen fibers, are required. The novel protein Semaphorin3A (Sema3A is associated with osteoprotection by regulating bone cells. The aims of this study were to investigate the effects of mechanical loads on Sema3A production and bone quality based on bone cells and collagen fibers around implants in rat maxillae. Grade IV-titanium threaded implants were placed at 4 weeks post-extraction in maxillary first molars. Implants received mechanical loads (10 N, 3 Hz for 1800 cycles, 2 days/week for 5 weeks from 3 weeks post-implant placement to minimize the effects of wound healing processes by implant placement. Bone structures, bone mineral density (BMD, Sema3A production and bone quality based on bone cells and collagen fibers were analyzed using microcomputed tomography, histomorphometry, immunohistomorphometry, polarized light microscopy and birefringence measurement system inside of the first and second thread (designated as thread A and B, respectively, as mechanical stresses are concentrated and differently distributed on the first two threads from the implant neck. Mechanical load significantly increased BMD, but not bone volume around implants. Inside thread B, but not thread A, mechanical load significantly accelerated Sema3A production with increased number of osteoblasts and osteocytes, and enhanced production of both type I and III collagen. Moreover, mechanical load also significantly induced preferential alignment of collagen fibers in the lower flank of thread B. These data demonstrate that mechanical load has different effects on Sema3A production and bone quality based on bone cells and collagen fibers between the inside threads of A and B. Mechanical load-induced Sema3A production may be differentially regulated by the type of bone structure or distinct stress distribution

  12. Analysis techniques of charging damage studied on three different high-current ion implanters

    Science.gov (United States)

    Felch, S. B.; Larson, L. A.; Current, M. I.; Lindsey, D. W.

    1989-02-01

    One of the Greater Silicon Valley Implant Users' Group's recent activities has been to sponsor a round-robin on charging damage, where identical wafers were implanted on three different state-of-the-art, high-current ion implanters. The devices studied were thin-dielectric (250 Å SiO2), polysilicon-gate MOS capacitors isolated by thick field oxide. The three implanters involved were the Varian/Extrion 160XP, the Eaton/Nova 10-80, and the Applied Materials PI9000. Each implanter vendor was given 48 wafers to implant with 100 keV As+ ions at a dose of 1 × 1016 cm-2. Parameters that were varied include the beam current, electron flood gun current, and chamber pressure. The charge-to-breakdown, breakdown voltage, and leakage current of several devices before anneal have been measured. The results from these tests were inconclusive as to the physical mechanism of charging and as to the effectiveness of techniques to reduce its impact on devices. However, the methodology of this study is discussed in detail to aid in the planning of future experiments. Authors' industrial affiliations: S.B. Felch, Varian Research Center, 611 Hansen Way, Palo Alto, CA 94303, USA; L.A. Larson, National Semiconductor Corp., P.O. Box 58090, Santa Clara, CA 95052-8090, USA; M.I. Current, Applied Materials, 3050 Bowers Ave., Santa Clara, CA 95054, USA; D.W. Lindsey, Eaton/NOVA, 931 Benicia Ave, Sunnyvale, CA 94086, USA.

  13. Can prenatal low-dose irradiation affect behavior of adult rats?

    International Nuclear Information System (INIS)

    Smajda, B.; Tomasova, L.; Kokocova, N.

    2011-01-01

    The aim of our study was to determine whether exposure of very low dose gamma-rays during the critical phase of brain development affects some selected behavioral parameters in adult rats. Pregnant female Wistar rats were irradiated with 1 Gy gamma-rays from a cobalt source at 17 th day of pregnancy. The progeniture of irradiated as well as non-irradiated females have undergone behavioral tests at the age of 3 months. Irradiated animals exhibited lower locomotor and exploratory activity in the open field test. (authors)

  14. Ion implantation and amorphous metals

    International Nuclear Information System (INIS)

    Hohmuth, K.; Rauschenbach, B.

    1981-01-01

    This review deals with ion implantation of metals in the high concentration range for preparing amorphous layers (>= 10 at%, implantation doses > 10 16 ions/cm 2 ). Different models are described concerning formation of amorphous phases of metals by ion implantation and experimental results are given. The study of amorphous phases has been carried out by the aid of Rutherford backscattering combined with the channeling technique and using transmission electron microscopy. The structure of amorphous metals prepared by ion implantation has been discussed. It was concluded that amorphous metal-metalloid compounds can be described by a dense-random-packing structure with a great portion of metal atoms. Ion implantation has been compared with other techniques for preparing amorphous metals and the adventages have been outlined

  15. Modification of high density polyethylene by gold implantation using different ion energies

    Energy Technology Data Exchange (ETDEWEB)

    Nenadović, M.; Potočnik, J. [INS Vinca, Laboratory of Atomic Physics, University of Belgrade, Mike Alasa 12–14, 11001 Belgrade (Serbia); Mitrić, M. [INS Vinca, Condensed Matter Physics Laboratory, University of Belgrade, Mike Alasa 12–14, 11001 Belgrade (Serbia); Štrbac, S. [ICTM Institute of Electrochemistry, University of Belgrade, Njegoseva 12, 11001 Belgrade (Serbia); Rakočević, Z., E-mail: zlatkora@vinca.rs [INS Vinca, Laboratory of Atomic Physics, University of Belgrade, Mike Alasa 12–14, 11001 Belgrade (Serbia)

    2013-11-01

    High density polyethylene (HDPE) samples were modified by Au{sup +} ion implantation at a dose of 5 × 10{sup 15} ions cm{sup −2}, using energies of 50, 100, 150 and 200 keV. The existence of implanted gold in the near-surface region of HDPE samples was confirmed by X-ray diffraction analysis. Surface roughness and Power Spectral Density analyses based on Atomic Force Microscopy (AFM) images of the surface topography revealed that the mechanism of HDPE modification during gold ion implantation depended on the energy of gold ions. Histograms obtained from phase AFM images indicated a qualitative change in the chemical composition of the surface during implantation with gold ions with different energies. Depth profiles obtained experimentally from cross-sectional Force Modulation Microscopy images and ones obtained from a theoretical simulation are in agreement for gold ions energies lower than 100 keV. The deviation that was observed for higher energies of the gold ions is explained by carbon precipitation in the near surface region of the HDPE, which prevented the penetration of gold ions further into the depth of the sample. - Highlights: • HDPE was implanted by Au{sup +} ions using energies of 50, 100, 150 and 200 keV. • Surface composition was analyzed from phase AFM images. • FMM depth profiles are in agreement with theoretical ones for energies up to 100 keV. • A deviation is observed for higher gold ion energies.

  16. Modification of high density polyethylene by gold implantation using different ion energies

    International Nuclear Information System (INIS)

    Nenadović, M.; Potočnik, J.; Mitrić, M.; Štrbac, S.; Rakočević, Z.

    2013-01-01

    High density polyethylene (HDPE) samples were modified by Au + ion implantation at a dose of 5 × 10 15 ions cm −2 , using energies of 50, 100, 150 and 200 keV. The existence of implanted gold in the near-surface region of HDPE samples was confirmed by X-ray diffraction analysis. Surface roughness and Power Spectral Density analyses based on Atomic Force Microscopy (AFM) images of the surface topography revealed that the mechanism of HDPE modification during gold ion implantation depended on the energy of gold ions. Histograms obtained from phase AFM images indicated a qualitative change in the chemical composition of the surface during implantation with gold ions with different energies. Depth profiles obtained experimentally from cross-sectional Force Modulation Microscopy images and ones obtained from a theoretical simulation are in agreement for gold ions energies lower than 100 keV. The deviation that was observed for higher energies of the gold ions is explained by carbon precipitation in the near surface region of the HDPE, which prevented the penetration of gold ions further into the depth of the sample. - Highlights: • HDPE was implanted by Au + ions using energies of 50, 100, 150 and 200 keV. • Surface composition was analyzed from phase AFM images. • FMM depth profiles are in agreement with theoretical ones for energies up to 100 keV. • A deviation is observed for higher gold ion energies

  17. Influence of dosing times on cisplatin-induced peripheral neuropathy in rats

    International Nuclear Information System (INIS)

    Seto, Yoshihiro; Okazaki, Fumiyasu; Horikawa, Keiji; Zhang, Jing; Sasaki, Hitoshi; To, Hideto

    2016-01-01

    Although cis-diamminedichloro-platinum (CDDP) exhibits strong therapeutic effects in cancer chemotherapy, its adverse effects such as peripheral neuropathy, nephropathy, and vomiting are dose-limiting factors. Previous studies reported that chronotherapy decreased CDDP-induced nephropathy and vomiting. In the present study, we investigated the influence of dosing times on CDDP-induced peripheral neuropathy in rats. CDDP (4 mg/kg) was administered intravenously at 5:00 or 17:00 every 7 days for 4 weeks to male Sprague–Dawley rats, and saline was given to the control group. To assess the dosing time dependency of peripheral neuropathy, von-Frey test and hot-plate test were performed. In order to estimate hypoalgesia, the hot-plate test was performed in rats administered CDDP weekly for 4 weeks. On day 28, the withdrawal latency to thermal stimulation was significantly prolonged in the 17:00-treated group than in the control and 5:00-treated groups. When the von-Frey test was performed to assess mechanical allodynia, the withdrawal threshold was significantly lower in the 5:00 and 17:00-treated groups than in the control group on day 6 after the first CDDP dose. The 5:00-treated group maintained allodynia throughout the experiment with the repeated administration of CDDP, whereas the 17:00-treated group deteriorated from allodynia to hypoalgesia. It was revealed that the severe of CDDP-induced peripheral neuropathy was inhibited in the 5:00-treated group, whereas CDDP-treated groups exhibited mechanical allodynia. These results suggested that the selection of an optimal dosing time ameliorated CDDP-induced peripheral neuropathy. The online version of this article (doi:10.1186/s12885-016-2777-0) contains supplementary material, which is available to authorized users

  18. Repair of spinal cord injury by implantation of bFGF-incorporated HEMA-MOETACL hydrogel in rats

    Science.gov (United States)

    Chen, Bo; He, Jianyu; Yang, Hao; Zhang, Qian; Zhang, Lingling; Zhang, Xian; Xie, En; Liu, Cuicui; Zhang, Rui; Wang, Yi; Huang, Linhong; Hao, Dingjun

    2015-03-01

    There is no effective strategy for the treatment of spinal cord injury (SCI). An appropriate combination of hydrogel materials and neurotrophic factor therapy is currently thought to be a promising approach. In this study, we performed experiments to evaluate the synergic effect of implanting hydroxyl ethyl methacrylate [2-(methacryloyloxy)ethyl] trimethylammonium chloride (HEMA-MOETACL) hydrogel incorporated with basic fibroblast growth factor (bFGF) into the site of surgically induced SCI. Prior to implantation, the combined hydrogel was surrounded by an acellular vascular matrix. Sprague-Dawley rats underwent complete spinal cord transection at the T-9 level, followed by implantation of bFGF/HEMA-MOETACL 5 days after transection surgery. Our results showed that the bFGF/HEMA-MOETACL transplant provided a scaffold for the ingrowth of regenerating tissue eight weeks after implantation. Furthermore, this newly designed implant promoted both nerve tissue regeneration and functional recovery following SCI. These results indicate that HEMA-MOETACL hydrogel is a promising scaffold for intrathecal, localized and sustained delivery of bFGF to the injured spinal cord and provide evidence for the possibility that this approach may have clinical applications in the treatment of SCI.

  19. Implanting Glioblastoma Spheroids into Rat Brains and Monitoring Tumor Growth by MRI Volumetry.

    Science.gov (United States)

    Löhr, Mario; Linsenmann, Thomas; Jawork, Anna; Kessler, Almuth F; Timmermann, Nils; Homola, György A; Ernestus, Ralf-Ingo; Hagemann, Carsten

    2017-01-01

    The outcome of patients suffering from glioblastoma multiforme (GBM) remains poor with a median survival of less than 15 months. To establish innovative therapeutical approaches or to analyze the effect of protein overexpression or protein knockdown by RNA interference in vivo, animal models are mandatory. Here, we describe the implantation of C6 glioma spheroids into the rats' brain and how to follow tumor growth by MRI scans. We show that C6 cells grown in Sprague-Dawley rats share several morphologic features of human glioblastoma like pleomorphic cells, areas of necrosis, vascular proliferation, and tumor cell invasion into the surrounding brain tissue. In addition, we describe a method for tumor volumetry utilizing the CISS 3D- or contrast-enhanced T1-weighted 3D sequence and freely available post-processing software.

  20. Biocompatibility of a new nanomaterial based on calcium silicate implanted in subcutaneous connective tissue of rats

    Directory of Open Access Journals (Sweden)

    Petrović Violeta

    2012-01-01

    Full Text Available The aim of the study was to investigate rat connective tissue response to a new calcium silicate system 7, 15, 30 and 60 days after implantation. Twenty Wistar albino male rats received two tubes half-filled with a new calcium silicate system (NCSS or MTA in subcutaneous tissue. The empty half of the tubes served as controls. Five animals were sacrificed after 7, 15, 30 and 60 days and samples of the subcutaneous tissue around implanted material were submitted to histological analysis. The intensity of inflammation was evaluated based on the number of inflammatory cells present. Statistical analysis was performed using one way ANOVA and Holm Sidak's multiple comparison tests. Mild to moderate inflammatory reaction was observed after 7, 15 and 30 days around a NCSS while mild inflammatory reaction was detected after 60 days of implantation. In the MTA group, mild to moderate inflammatory reaction was found after 7 and 15 days while mild inflammatory reaction was present after 30 and 60 days. There was no statistically significant difference in the intensity of inflammatory reactions between the tested materials and control groups in any experimental period (ANOVA p>0.05. Regarding the intensity of inflammatory reactions at different experimental periods, a statistically significant difference was observed between 7 and 30 days, 7 and 60 days and 15 to 60 days for both materials. For the controls, a statistically significant difference was found between 7 and 60 days and 15 and 60 days of the experiment (Holm Sidak < p 0.001. Subcutaneous tissue of rats showed good tolerance to a new calcium silicate system. Inflammatory reaction was similar to that caused by MTA. [Projekat Ministarstva nauke Republike Srbije, br. 172026

  1. Effects of 3,5-diiodo-L-thyronine on the liver of high fat diet fed rats

    Directory of Open Access Journals (Sweden)

    Marco Giammanco

    2016-06-01

    Full Text Available Experimental studies have highlighted that the administration of 3,5-diiodo-L-thyronine (T2 to rats fed diets rich in lipids induces a decrease of cholesterol and triglycerides plasma levels and body weight (BW without inducing liver steatosis. On the basis of these observations we carried out some experimental in vivo studies to assess the effects of multiple high doses of T2 on the pituitary thyroid axis of rats fed diet rich in lipids. Fifteen male Wistar rats were divided into three groups of five animals each. The first group (N group received standard diet, the second group was fed with a high fat diet (HFD group, while the third group (HFDT2 group was additionally given T2 intraperitoneally at a dose level of 70 µg/100 g of BW three times a week up to four weeks. At the end of the treatment, blood sample from each animal was collected, centrifuged and the serum was stored at -20°C. The serum concentrations of thyroidstimulating hormone (TSH, triiodothyronine, thyroxine, adrenocorticotropic hormone, triglycerides, cholesterol, glucose, alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase were then determined. In addition, liver of rats was examined by histology in order to assess the presence and degree of steatosis. The administration of T2 to rats fed with a high fat diet suppressed TSH secretion (P=0.013 while no steatosis was observed in the liver of these animals. Our data show that multiple administrations of high doses of T2 to rats fed diets rich in lipid inhibit TSH secretion and prevent the onset of liver steatosis in these animals.

  2. Maternal deprivation affects the neuromuscular protein profile of the rat colon in response to an acute stressor later in life.

    Science.gov (United States)

    Lopes, Luísa V; Marvin-Guy, Laure F; Fuerholz, Andreas; Affolter, Michael; Ramadan, Ziad; Kussmann, Martin; Fay, Laurent B; Bergonzelli, Gabriela E

    2008-04-30

    Early life stress as neonatal maternal deprivation (MD) predisposes rats to alter gut functions in response to acute psychological stressors in adulthood, mimicking features of irritable bowel syndrome (IBS). We applied proteomics to investigate whether MD permanently changes the protein profile of the external colonic neuromuscular layer that may condition the molecular response to an acute stressor later in life. Male rat pups were separated 3 h/day from their mothers during the perinatal period and further submitted to water avoidance (WA) stress during adulthood. Proteins were extracted from the myenteric plexus-longitudinal muscle of control (C), WA and MD+WA rat colon, separated on 2D gels, and identified by mass spectrometry. MD amplified the WA-induced protein changes involved in muscle contractile function, suggesting that stress accumulation along life imbalances the muscle tone towards hypercontractility. Our results also propose a stress dependent regulation of gluconeogenesis. Secretogranin II - the secretoneurin precursor - was induced by MD. The presence of secretoneurin in myenteric ganglia may partially explain the stress-mediated modulation of gastrointestinal motility and/or mucosal inflammation previously described in MD rats. In conclusion, our findings suggest that neonatal stress alters the responses to acute stress in adulthood in intestinal smooth muscle and enteric neurons.

  3. Evolution of arsenic in high fluence plasma immersion ion implanted silicon: Behavior of the as-implanted surface

    Energy Technology Data Exchange (ETDEWEB)

    Vishwanath, V. [Applied Materials, 3225 Oakmead Village Drive, Santa Clara, CA 95052 (United States); Demenev, E. [Center for Materials and Microsystems, Fondazione Bruno Kessler, Via Sommarive 18, 38123 Povo, Trento (Italy); Department of Molecular Science and Nanosystems, Ca’Foscari University, Dorsoduro 2137, 30123 Venice (Italy); Giubertoni, D., E-mail: giuberto@fbk.eu [Center for Materials and Microsystems, Fondazione Bruno Kessler, Via Sommarive 18, 38123 Povo, Trento (Italy); Vanzetti, L. [Center for Materials and Microsystems, Fondazione Bruno Kessler, Via Sommarive 18, 38123 Povo, Trento (Italy); Koh, A.L. [Stanford Nanocharacterization Laboratory, Stanford University, 476 Lomita Mall, Stanford, CA 94305 (United States); Steinhauser, G. [Colorado State University, Environmental and Radiological Health Sciences, Fort Collins, CO 80523 (United States); Leibniz Universität Hannover, Institut für Radioökologie und Strahlenschutz, 30419 Hannover (Germany); Pepponi, G.; Bersani, M. [Center for Materials and Microsystems, Fondazione Bruno Kessler, Via Sommarive 18, 38123 Povo, Trento (Italy); Meirer, F., E-mail: f.meirer@uu.nl [Inorganic Chemistry and Catalysis, Utrecht University, Utrecht 3584 CG (Netherlands); Foad, M.A. [Applied Materials, 3225 Oakmead Village Drive, Santa Clara, CA 95052 (United States)

    2015-11-15

    Highlights: • Samples prepared by high fluence, low-energy PIII of AsH{sub 3}{sup +} on Si(1 0 0) were studied. • PIII is of high technological interest for ultra-shallow doping and activation. • We used a multi-technique approach to study the As-implanted surface. • We show that PIII presents a new set of problems that needs to be tackled. • The presented study goes toward understanding the root mechanisms involved. - Abstract: High fluence (>10{sup 15} ions/cm{sup 2}) low-energy (<2 keV) plasma immersion ion implantation (PIII) of AsH{sub 3}{sup +} on (1 0 0) silicon was investigated, with the focus on stability and retention of the dopant. At this dose, a thin (∼3 nm) amorphous layer forms at the surface, which contains about 45% arsenic (As) in a silicon and oxygen matrix. The presence of silicon indicates that the layer is not only a result of deposition, but predominantly ion mixing. High fluence PIII introduces high concentration of arsenic, modifying the stopping power for incoming ions resulting in an increased deposition. When exposed to atmosphere, the arsenic rich layer spontaneously evolves forming arsenolite As{sub 2}O{sub 3} micro-crystals at the surface. The micro-crystal formation was monitored over several months and exhibits typical crystal growth kinetics. At the same time, a continuous growth of native silicon oxide rich in arsenic was observed on the exposed surface, suggesting the presence of oxidation enhancing factors linked to the high arsenic concentration at the surface.

  4. Rutherford backscatter measurements on tellurium and cadmium implanted gallium arsenide

    International Nuclear Information System (INIS)

    Bell, E.C.

    1979-10-01

    The primary aim of the work described in this thesis was to examine implanted layers of the dopant impurities cadmium and tellurium in gallium arsenide and to experimentally assess their potential for producing electrically active layers. 1.5 MeV Rutherford backscattering measurements of lattice disorder and atom site location have been used to assess post implantation thermal annealing and elevated temperature implantations to site the dopant impurities on either gallium or arsenic lattice positions in an otherwise undisordered lattice. Pyrolitically deposited silicon dioxide was used as an encapsulant to prevent thermal dissociation of the gallium arsenide during annealing. It has been shown that high doses of cadmium and tellurium can be implanted without forming amorphous lattice disorder by heating the gallium arsenide during implantation to relatively low temperatures. Atom site location measurements have shown that a large fraction of a tellurium dose implanted at 180 0 C is located on or near lattice sites. Channeled backscatter measurements have shown that there is residual disorder or lattice strain in gallium arsenide implanted at elevated temperatures. The extent of this disorder has been shown to depend on the implanted dose and implantation temperature. The channeling effect has been used to measure annealing of the disorder. (author)

  5. Structural properties of Ne implanted GaN

    Energy Technology Data Exchange (ETDEWEB)

    Majid, A; Zhu, J J; Liu, W; Lu, G J; Liu, W B; Zhang, L Q; Liu, Z S; Wang, H; Zhao, D G; Zhang, S M; Jiang, D S; Wang, Y T; Yang, H [State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, PO Box 912, Beijing 100083 (China); Ali, A; Israr, M [Advance Materials Physics Laboratory, Physics Department, Quaid-i-Azam University, Islamabad (Pakistan)], E-mail: abdulmajid40@yahoo.com

    2008-03-15

    We report a study on the micro-structural changes in GaN due to neon ion implantation using the x-ray diffraction and Raman scattering techniques. An implantation dose of 10{sup 14} cm{sup -2} was found unable to produce lattice deformation observable by Raman measurements. For higher doses of implantation several disorder activated Raman scattering centers were observed which corroborate the literature. A new dose dependent feature has been recorded at 1595 cm{sup -1} for higher implantation doses which is suggested to be the vibrational mode of microcavities produced in the lattice.

  6. Structural properties of Ne implanted GaN

    International Nuclear Information System (INIS)

    Majid, A; Zhu, J J; Liu, W; Lu, G J; Liu, W B; Zhang, L Q; Liu, Z S; Wang, H; Zhao, D G; Zhang, S M; Jiang, D S; Wang, Y T; Yang, H; Ali, A; Israr, M

    2008-01-01

    We report a study on the micro-structural changes in GaN due to neon ion implantation using the x-ray diffraction and Raman scattering techniques. An implantation dose of 10 14 cm -2 was found unable to produce lattice deformation observable by Raman measurements. For higher doses of implantation several disorder activated Raman scattering centers were observed which corroborate the literature. A new dose dependent feature has been recorded at 1595 cm -1 for higher implantation doses which is suggested to be the vibrational mode of microcavities produced in the lattice

  7. Asili na Chimbuko la Wazungumzaji wa Kimakunduchi: Hoja za ...

    African Journals Online (AJOL)

    Wakati tukiwa tunasherehekea mafanikio ya lugha ya Kiswahili katika nyanja mbalimbali, hatuna budi kujiuliza katika mijadala yetu ni kwa kiwango gani tumezishirikisha lahaja za Kiswahili katika kubaini mambo mbalimbali ikiwemo historia ya lugha hii. Tukumbuke kwamba wakati wa uteuzi wa lahaja ya Kiunguja kuwa ...

  8. Kuingiliana kwa Lugha ya Kiswahili na Kiingereza: Uswahilishaji wa ...

    African Journals Online (AJOL)

    Kuingiliana kwa lugha ni taaluma katika uwanja wa isimu inayohusu lugha zinazoingiliana na kuathiriana. Kuingiliana kwa lugha sio jambo jipya katika dunia. Watu ambao ndio watumiaji wa lugha wamesababisha lugha kuiingiliana waliposafiri au kuhama sehemu moja hadi nyingine kutokana na sababu za kiuchumi, ...

  9. Iterative metal artifact reduction improves dose calculation accuracy. Phantom study with dental implants

    Energy Technology Data Exchange (ETDEWEB)

    Maerz, Manuel; Mittermair, Pia; Koelbl, Oliver; Dobler, Barbara [Regensburg University Medical Center, Department of Radiotherapy, Regensburg (Germany); Krauss, Andreas [Siemens Healthcare GmbH, Forchheim (Germany)

    2016-06-15

    Metallic dental implants cause severe streaking artifacts in computed tomography (CT) data, which affect the accuracy of dose calculations in radiation therapy. The aim of this study was to investigate the benefit of the metal artifact reduction algorithm iterative metal artifact reduction (iMAR) in terms of correct representation of Hounsfield units (HU) and dose calculation accuracy. Heterogeneous phantoms consisting of different types of tissue equivalent material surrounding metallic dental implants were designed. Artifact-containing CT data of the phantoms were corrected using iMAR. Corrected and uncorrected CT data were compared to synthetic CT data to evaluate accuracy of HU reproduction. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated in Oncentra v4.3 on corrected and uncorrected CT data and compared to Gafchromic trademark EBT3 films to assess accuracy of dose calculation. The use of iMAR increased the accuracy of HU reproduction. The average deviation of HU decreased from 1006 HU to 408 HU in areas including metal and from 283 HU to 33 HU in tissue areas excluding metal. Dose calculation accuracy could be significantly improved for all phantoms and plans: The mean passing rate for gamma evaluation with 3 % dose tolerance and 3 mm distance to agreement increased from 90.6 % to 96.2 % if artifacts were corrected by iMAR. The application of iMAR allows metal artifacts to be removed to a great extent which leads to a significant increase in dose calculation accuracy. (orig.) [German] Metallische Implantate verursachen streifenfoermige Artefakte in CT-Bildern, welche die Dosisberechnung beeinflussen. In dieser Studie soll der Nutzen des iterativen Metall-Artefakt-Reduktions-Algorithmus iMAR hinsichtlich der Wiedergabetreue von Hounsfield-Werten (HU) und der Genauigkeit von Dosisberechnungen untersucht werden. Es wurden heterogene Phantome aus verschiedenen Arten gewebeaequivalenten Materials mit

  10. Plasma Immersion Ion Implantation in Radio Frequency Plasma

    International Nuclear Information System (INIS)

    Bora, B.; Bhuyan, H.; Wyndham, E.

    2013-01-01

    Plasma immersion ion implantation (PIII) has attracted wide interests since it emulates conventional ion-beam ion implantation (IBII) in niche applications. For instance, the technique has very high throughput, the implantation time is independent of the sample size, and samples with an irregular shape can be implanted without complex beam scanning or sample manipulation. For uniform ion implantation and deposition on to different substrates, like silicon, stainless steel etc., a capacitive coupled Radio frequency (RF), 13.6 MHz, plasma is used. During the PIII process, the physical parameters which are expected to play crucial rule in the deposition process like RF power, Negative pulse voltage and pulse duration, gas type and gas mixture, gas flow rates and the implantation dose are studied. The ion dose is calculated by dynamic sheath model and the plasma parameters are calculated from the V-I characteristic and power balance equation by homogeneous model of rf plasma discharge considering Ohmic as well as Stochastic heating. The correlations between the yield of the implantation process and the physical parameters as well as plasma parameters are discussed. (author)

  11. Detection and reduction of tungsten contamination in ion implantation processes

    International Nuclear Information System (INIS)

    Polignano, M.L.; Galbiati, A.; Grasso, S.; Mica, I.; Barbarossa, F.; Magni, D.

    2016-01-01

    In this paper, we review the results of some studies addressing the problem of tungsten contamination in implantation processes. For some tests, the implanter was contaminated by implantation of wafers with an exposed tungsten layer, resulting in critical contamination conditions. First, DLTS (deep level transient spectroscopy) measurements were calibrated to measure tungsten contamination in ion-implanted samples. DLTS measurements of tungsten-implanted samples showed that the tungsten concentration increases linearly with the dose up to a rather low dose (5 x 10 10 cm -2 ). Tungsten deactivation was observed when the dose was further increased. Under these conditions, ToF-SIMS revealed tungsten at the wafer surface, showing that deactivation was due to surface segregation. DLTS calibration could therefore be obtained in the linear dose regime only. This calibration was used to evaluate the tungsten contamination in arsenic implantations. Ordinary operating conditions and critical contamination conditions of the equipment were compared. A moderate tungsten contamination was observed in samples implanted under ordinary operating conditions. This contamination was easily suppressed by a thin screen oxide. On the contrary, implantations in critical conditions of the equipment resulted in a relevant tungsten contamination, which could be reduced but not suppressed even by a relatively thick screen oxide (up to 150 Aa). A decontamination process consisting of high dose implantations of dummy wafers was tested for its efficiency to remove tungsten and titanium contamination. This process was found to be much more effective for titanium than for tungsten. Finally, DLTS proved to be much more sensitive that TXRF (total reflection X-ray fluorescence) in detecting tungsten contamination. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Detection and reduction of tungsten contamination in ion implantation processes

    Energy Technology Data Exchange (ETDEWEB)

    Polignano, M.L.; Galbiati, A.; Grasso, S.; Mica, I.; Barbarossa, F.; Magni, D. [STMicroelectronics, Agrate Brianza (Italy)

    2016-12-15

    In this paper, we review the results of some studies addressing the problem of tungsten contamination in implantation processes. For some tests, the implanter was contaminated by implantation of wafers with an exposed tungsten layer, resulting in critical contamination conditions. First, DLTS (deep level transient spectroscopy) measurements were calibrated to measure tungsten contamination in ion-implanted samples. DLTS measurements of tungsten-implanted samples showed that the tungsten concentration increases linearly with the dose up to a rather low dose (5 x 10{sup 10} cm{sup -2}). Tungsten deactivation was observed when the dose was further increased. Under these conditions, ToF-SIMS revealed tungsten at the wafer surface, showing that deactivation was due to surface segregation. DLTS calibration could therefore be obtained in the linear dose regime only. This calibration was used to evaluate the tungsten contamination in arsenic implantations. Ordinary operating conditions and critical contamination conditions of the equipment were compared. A moderate tungsten contamination was observed in samples implanted under ordinary operating conditions. This contamination was easily suppressed by a thin screen oxide. On the contrary, implantations in critical conditions of the equipment resulted in a relevant tungsten contamination, which could be reduced but not suppressed even by a relatively thick screen oxide (up to 150 Aa). A decontamination process consisting of high dose implantations of dummy wafers was tested for its efficiency to remove tungsten and titanium contamination. This process was found to be much more effective for titanium than for tungsten. Finally, DLTS proved to be much more sensitive that TXRF (total reflection X-ray fluorescence) in detecting tungsten contamination. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  13. Low-dose acute vanillin is beneficial against harmaline-induced tremors in rats.

    Science.gov (United States)

    Abdulrahman, Al Asmari; Faisal, Kunnathodi; Meshref, Ali Al Amri; Arshaduddin, Mohammed

    2017-03-01

    To study the effect of pretreatment with low doses of vanillin, a flavoring agent used as a food additive, on harmaline-induced tremor in rats. Sprague Dawley rats (110 ± 5 g) were divided into groups of six animals each. Vanillin (6.25 mg, 12.5 mg, and 25 mg/kg) was administered by gavage to different groups of rats, 30 minutes before the induction of tremor. Harmaline (10 mg/kg, i.p.) was used for the induction of tremor. The latency of onset, duration, tremor intensity, tremor index, and spontaneous locomotor activity were recorded. A separate batch of animals was used for the determination of serotonin (5HT) and 5 hydroxyindole acetic acid (5HIAA) levels in the brain. Harmaline treatment resulted in characteristic tremor that lasted for more than 2 hours and decreased the locomotor activity of rats. Pre-treatment with vanillin significantly reduced the duration, intensity, and tremor index of harmaline-treated animals. Vanillin treatment also significantly attenuated harmaline-induced decrease in the locomotor activity. An increase in 5HT levels and the changes in 5HIAA/5HT ratio observed in harmaline treated rats were significantly corrected in vanillin pretreated animals. Vanillin in low doses reduces harmaline-induced tremor in rats, probably through its modulating effect on serotonin levels in the brain. These findings suggest a beneficial effect of vanillin in essential tremor.

  14. Annealing of Al implanted 4H silicon carbide

    International Nuclear Information System (INIS)

    Hallen, A; Suchodolskis, A; Oesterman, J; Abtin, L; Linnarsson, M

    2006-01-01

    Al ions were implanted with multiple energies up to 250 keV at elevated temperatures in n-type 4H SiC epitaxial layers to reach a surface concentration of 1x10 20 cm -3 . These samples were then annealed at temperatures between 1500 and 1950 deg. C. A similar 4H SiC epitaxial sample was implanted by MeV Al ions to lower doses and annealed only at 200 and 400 deg. C. After annealing, cross-sections of the samples were characterized by scanning spreading resistance microscopy (SSRM). The results show that the resistivity of high-dose Al implanted samples has not reached a saturated value, even after annealing at the highest temperature. For the MeV Al implanted sample, the activation of Al has not yet started, but a substantial annealing of the implantation induced damage can be seen from the SSRM depth profiles

  15. A 4-Week Repeated-Dose Oral Toxicity Study of Bojungikgi-Tang in Crl:CD Sprague Dawley Rats

    Directory of Open Access Journals (Sweden)

    Sae-Rom Yoo

    2017-01-01

    Full Text Available Traditional herbal medicines have been used for centuries in Asian countries. However, recent studies have led to increasing concerns about the safety and toxicity of herbal prescriptions. Bojungikgi-tang (BJIGT, a herbal decoction, has been used in Korea to improve physical strength. To establish the safety information, BJIGT water extract was evaluated in a 4-week repeated-dose oral toxicity test in Crl:CD Sprague Dawley rats. BJIGT was orally administered in daily doses of 0, 500, 1000, and 2000 mg/kg/day for 4 weeks via oral gavage in male and female rats. We examined the mortality, clinical signs, body weight change, food intake, organ weights, hematology, serum biochemistry, and urinalysis parameters. No significant changes were observed in mortality, clinical sings, body weight, food intake, organ weights, hematology, serum biochemistry, and urinalysis parameters between the control group and the BJIGT-treated groups in the rats of both sexes. The results indicate that BJIGT did not induce toxic effects at a dose level up to 2000 mg/kg in rats. Thus, this concentration is considered the nonobservable effect dose in rats and is appropriate for a 13-week subchronic toxicity study.

  16. Perturbation of cobalt 60 radiation doses by metal objects implanted during oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Tatcher, M.; Kuten, A.; Helman, J.; Laufer, D.

    1984-01-01

    The influence on cobalt 60 dose distributions of typical metal parts used in oral and maxillofacial surgery was studied. Relative doses were determined by exposing x-ray films in a polystyrene phantom set-up containing samples of vitallium, titanium, and stainless steel. Optical densities were converted to doses with the aid of sensitometric curves. The results show that for normal incidence there is a 25% to 40% increase in dose at the entrance side of the metal and a 20% to 25% decrease in dose at the exit side. The enhancement effect falls off rapidly and becomes negligible at about 1 mm from the interface. The reduction effect decreases more gradually and is still evident at distances of a few centimeters. These dose perturbations should be taken into account in the planning of radiation therapy for patients in whom metal objects have been implanted

  17. Results from the WA92 experiment

    International Nuclear Information System (INIS)

    Malferrari, L.

    1995-01-01

    We report on a search for beauty particles produced in π - -nucleon interactions at √(s)≅26 GeV at the CERN Ω' spectrometer. Data were collected using the WA92 apparatus, which included a high-resolution imaging detector and a system for triggering on secondary vertices. The search for beauty decays using conventional analysis procedures is described and a new event-selection method, based on neural-network techniques, is presented. Results obtained with the new and the conventional methods are compared. (orig.)

  18. Highly Stripped Ion Sources for MeV Ion Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Hershcovitch, Ady

    2009-06-30

    Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high

  19. Transverse microanalysis of high energy Ion implants

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, S.P.; Jamieson, D.N.; Nugent, K.W.; Prawer, S. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    High energy ion implants in semiconductor materials have been analyzed by Channeling Contrast Microscopy (CCM) perpendicular to the implant direction, allowing imaging of the entire ion track. The damage produced by Channeled and Random 1.4 MeV H{sup +} implants into the edge of a <100> type IIa diamond wafer were analyzed by channeling into the face of the crystal. The results showed negligible damage in the surface region of the implants, and swelling induced misalignment at the end of range of the implants. Channeled 1.4 MeV H{sup +} implants in diamond had a range only 9% deeper than Random implants, which could be accounted for by dechanneling of the beam. The channeling of H{sup +}{sub 2} ions has been previously found to be identical to that of protons of half energy, however the current experiment has shown a 1% increase in {chi}{sub min} for H{sup +}{sub 2} in diamond compared to H{sup +} at 1,2 MeV per proton. This is due to repulsion between protons within the same channel. 5 refs., 2 figs.

  20. Transverse microanalysis of high energy Ion implants

    Energy Technology Data Exchange (ETDEWEB)

    Dooley, S P; Jamieson, D N; Nugent, K W; Prawer, S [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    High energy ion implants in semiconductor materials have been analyzed by Channeling Contrast Microscopy (CCM) perpendicular to the implant direction, allowing imaging of the entire ion track. The damage produced by Channeled and Random 1.4 MeV H{sup +} implants into the edge of a <100> type IIa diamond wafer were analyzed by channeling into the face of the crystal. The results showed negligible damage in the surface region of the implants, and swelling induced misalignment at the end of range of the implants. Channeled 1.4 MeV H{sup +} implants in diamond had a range only 9% deeper than Random implants, which could be accounted for by dechanneling of the beam. The channeling of H{sup +}{sub 2} ions has been previously found to be identical to that of protons of half energy, however the current experiment has shown a 1% increase in {chi}{sub min} for H{sup +}{sub 2} in diamond compared to H{sup +} at 1,2 MeV per proton. This is due to repulsion between protons within the same channel. 5 refs., 2 figs.

  1. Host inflammatory response to polypropylene implants: insights from a quantitative immunohistochemical and birefringence analysis in a rat subcutaneous model

    Directory of Open Access Journals (Sweden)

    Alessandro Prudente

    2016-06-01

    Full Text Available ABSTRACT Objectives To describe acute and sub acute aspects of histological and immunohistochemical response to PP implant in a rat subcutaneous model based on objective methods. Materials and Methods Thirty rats had a PP mesh subcutaneously implanted and the same dissection on the other side of abdomen but without mesh (sham. The animals were euthanized after 4 and 30 days. Six slides were prepared using the tissue removed: one stained with hematoxylin-eosin (inflammation assessment; one unstained (birefringence evaluation and four slides for immunohistochemical processing: IL-1 and TNF-α (pro-inflammatory cytokines, MMP-2 (collagen metabolism and CD-31 (angiogenesis. The area of inflammation, the birefringence index, the area of immunoreactivity and the number of vessels were objectively measured. Results A larger area of inflammatory reaction was observed in PP compared to sham on the 4th and on the 30th day (p=0.0002. After 4 days, PP presented higher TNF (p=0.0001 immunoreactivity than sham and no differences were observed in MMP-2 (p=0.06 and IL-1 (p=0.08. After 30 days, a reduction of IL-1 (p=0.010 and TNF (p=0.016 for PP and of IL-1 (p=0.010 for sham were observed. Moreover, area of MMP-2 immunoreactivity decreased over time for PP group (p=0.018. Birefringence index and vessel counting showed no differences between PP and sham (p=0.27 and p=0.58, respectively. Conclusions The implantation of monofilament and macroporous polypropylene in the subcutaneous of rats resulted in increased inflammatory activity and higher TNF production in the early post implant phase. After 30 days, PP has similar cytokines immunoreactivity, vessel density and extracellular matrix organization.

  2. The teratogenic effects of low dose 60Co γ-rays on the early pregnant rats

    International Nuclear Information System (INIS)

    Lu Chunlin

    1991-01-01

    The pregnant Wistar rats were exposed to 0.5 Gy and 1.0 Gy 60 Co γ-rays at the 9th day after conception. The results: 60 Co γ-rays at dose of 1.0 Gy could induced many defects: excenphaly, hydrocephalus, gastroschisis, cleft palate and cleft lip, anophthalmia, microphthalmia, shorten tail and absent tail in surviving fetuses. The growth retardation was found from the parameters of fetal weight, height, head circle and development of skeleton. In the group of radiation dose 0.5 Gy, only hydrocephalus, absent tail and growth retardation of skeleton appeared. The results suggest that low-dose exposure in the early pregnant rats can induce fetal defects and growth retardation. The probable mechanism of teratogen and growth retardation was discussed. The cAMP levels of brain and liver of rat fetuses were reported

  3. A dynamic model for the estimation of optimum timing of computed tomography scan for dose evaluation of 125I or 103Pd seed implant of prostate

    International Nuclear Information System (INIS)

    Yue Ning; Dicker, Adam P.; Corn, Benjamin W.; Nath, Ravinder; Waterman, Frank M.

    1999-01-01

    Purpose/Objective: The dosimetric evaluation of permanent 125 I or 103 Pd prostate implant is based on the assumption that both prostate and seeds are static throughout the entire treatment time which lasts months. However, the prostate is often edematous after the surgical implantation of seeds. Therefore, both the volume of the prostate and the seed locations change dynamically as the edema resolves. This effect has impact on the validity of postimplant analysis based upon a CT scan. If a CT scan is taken too early after implantation while there is edema in the prostate, the dose delivered by the implant may be underestimated. If the imaging is delayed too long, the dose may be overestimated. The magnitude of this effect depends on both of the half-life of the isotope used and the half-life and magnitude of the edema. This study describes a dynamic biomathematical model which takes edema into account in calculating the dose delivered by the implant and is used to investigate the optimum time to obtain the postimplant CT scan. Materials and Methods: The dynamic biomathematical model is a numerical integration of the accumulated dose in which the prostate dimensions, the seed locations, and the source strength are all functions of time. The function which describes the change in prostate dimensions and seed locations as a function of time was determined in a separate study by analysis of serial postimplant CT scans. Dose-volume histograms (DVH) of the prostate for the total dose generated by the dynamic model are compared to DVHs generated by CT scans simulated for postimplant intervals ranging from 0 to 300 days after the implantation for 30 different combinations of the magnitude and duration of edema. Results: DVHs of the prostate calculated by taking edema into account show that the time of obtaining a CT scan for postimplant analysis is critical to the accuracy of dose evaluations. The comparison of the DVHs generated by the dynamic model to those generated by

  4. Basic study on low dose radiation effect: SOD activity of immune organs and hemogram in rats

    International Nuclear Information System (INIS)

    Yamaoka, Kiyonori; Kaneko, Ichiro; Mizutani, Takeo; Nakano, Kazushiro; Edamatsu, Rei; Mori, Akitane.

    1989-01-01

    We examined the effect of low dose radiation on SOD activities of immune organs such as thymus, spleen, bone marrow in rats and hematological findings changes. Animals were exposed to radiation in a wholebody fashion, 4 hours before sacrifice. SOD activities in thymus and bone marrow cells from the rats X-ray irradiated at doses of 0.25∼0.50 Gy/10 min were enhanced in comparison with those of non-irradiated rats. The enhancement was also observed in spleen cells obtained from group of rats irradiated at 0.05 Gy/10 min. Radiation exposure with over 0.50 Gy/10 min gave rats inhibitory responses in those immune organs. The changes in homogram were not observed with γ-ray exposure of less than 0.10 Gy/10 min. (author)

  5. Decreasing Irradiated Rat Lung Volume Changes Dose-Limiting Toxicity From Early to Late Effects

    Energy Technology Data Exchange (ETDEWEB)

    Veen, Sonja J. van der; Faber, Hette; Ghobadi, Ghazaleh [Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Brandenburg, Sytze [KVI Center for Advanced Radiation Research, University of Groningen, Groningen (Netherlands); Langendijk, Johannes A. [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Coppes, Robert P. [Department of Cell Biology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Luijk, Peter van, E-mail: p.van.luijk@umcg.nl [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands)

    2016-01-01

    Purpose: Technological developments in radiation therapy result in smaller irradiated volumes of normal tissue. Because the risk of radiation therapy-induced toxicity generally depends on irradiated volume, changing volume could change the dose-limiting toxicity of a treatment. Recently, in our rat model, we found that early radiation-induced lung dysfunction (RILD) was closely related to irradiated volume dependent vascular remodeling besides inflammation. The exact relationship between early and late RILD is still unknown. Therefore, in this preclinical study we investigated the dose-volume relationship of late RILD, assessed its dependence on early and late pathologies and studied if decreasing irradiated volume changed the dose-limiting toxicity. Methods and Materials: A volume of 25%, 32%, 50%, 63%, 88%, or 100% of the rat lung was irradiated using protons. Until 26 weeks after irradiation, respiratory rates were measured. Macrovascular remodeling, pulmonary inflammation, and fibrosis were assessed at 26 weeks after irradiation. For all endpoints dose-volume response curves were made. These results were compared to our previously published early lung effects. Results: Early vascular remodeling and inflammation correlated significantly with early RILD. Late RILD correlated with inflammation and fibrosis, but not with vascular remodeling. In contrast to the early effects, late vascular remodeling, inflammation and fibrosis showed a primarily dose but not volume dependence. Comparison of respiratory rate increases early and late after irradiation for the different dose-distributions indicated that with decreasing irradiated volumes, the dose-limiting toxicity changed from early to late RILD. Conclusions: In our rat model, different pathologies underlie early and late RILD with different dose-volume dependencies. Consequently, the dose-limiting toxicity changed from early to late dysfunction when the irradiated volume was reduced. In patients, early and late

  6. Effect of dose rate on the translocation yield in rat spermatogonia

    International Nuclear Information System (INIS)

    Vyglenov, A.; Rudnitski, T.; Kokhmanska-Tvardovska, A.

    1987-01-01

    The effectiveness of chronic gamma-irradiation with dose rate 1.10 -4 Gy/min on the yield of reciprocal translocations in rat spermatogonia was studied. Comparsion was made with acute gamma-irradiation at emissive power 1,23 Gy/min. Emissive power decrease by four orders reduced 12 times the extent of genetic injury - from 34,9 down to 3 translocations per cellx10 -5 /cGy. In this respect, the rat is close to the laboratory mouse

  7. high doses of prolactin inhibit testosterone secretion in rat leydig cells

    African Journals Online (AJOL)

    Femi Olaleye

    1 The effect of prolactin on dispersed rat Leydig cells was investigated. Leydig cells from adult rat testes of proven fertility were isolated via collagenase digestion and dispersion. About 100,000 Leydig .... Hormones, Drugs and Reagents.

  8. Hardness of ion implanted ceramics

    International Nuclear Information System (INIS)

    Oliver, W.C.; McHargue, C.J.; Farlow, G.C.; White, C.W.

    1985-01-01

    It has been established that the wear behavior of ceramic materials can be modified through ion implantation. Studies have been done to characterize the effect of implantation on the structure and composition of ceramic surfaces. To understand how these changes affect the wear properties of the ceramic, other mechanical properties must be measured. To accomplish this, a commercially available ultra low load hardness tester has been used to characterize Al 2 O 3 with different implanted species and doses. The hardness of the base material is compared with the highly damaged crystalline state as well as the amorphous material

  9. Conductivity in insulators due to implantation of conducting species

    International Nuclear Information System (INIS)

    Prawer, S.; Kalish, R.

    1993-01-01

    Control of the surface conductivity of insulators can be accomplished by high dose ion implantation of conductive species. The use of C + as the implant species is particularly interesting because C can either form electrically insulating sp 3 bonds or electrically conducting sp 2 bonds. In the present work, fused quartz plates have been irradiated with 100 keV C + ions to doses up to 1 x 10 17 ions/cm 2 at room temperature and at 200 deg C. The ion beam induced conductivity was monitored in-situ and was found to increase by up to 8 orders to magnitude for the ion dose range studied. Xe implantations over a similar range did not induce any changes in the conductivity showing that the increase in conductivity is caused by the presence of the C in the fused quartz matrix and not by damage. The dependence of the conductivity on implantation temperature and on post implantation annealing sheds light on the clustering of the C implants. The temperature dependence of the conductivity for the highest doses employed (1 x 10 17 C + /cm 2 ) can be described very well by lnσ α T. This is considered to be a peculiar dependence which does not comply with any of the standard models for conduction. 9 refs., 1 tab., 6 figs

  10. Beam current transformer (BCT) for experiment WA1/2

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    In experiment WA1/2, a 400 GeV proton beam from the SPS was directed at a target, downstream of which a hadron line selected, in several narrow momentum bands, a beam of either pi+ and K+ or pi- and K-. These neutrino-parent particles, before entering a 292 m long decay tunnel, passed through a set of 2 BCTs of a design seen here. They measured the hadron intensity (10^10 to 10^11 particles/pulse) with a precision of the order of 1%. There were 2 of them, for enhanced precision and confidence. After the discovery of neutral currents in the Gargamelle-experiment, WA1/2 was the first follow-up, high-precision experiment (Z.Phys.C35, 443-452, 1987 and Z.Phys.C45, 361-379, 1990). See also 7706516X.

  11. Dose-response relationship of rat aryl hydrocarbon hydroxylase and epoxide hydratase induction

    Energy Technology Data Exchange (ETDEWEB)

    Gielen, J.E.; Goujon, F.M.; Sele-Doyen, J.; Van Cantfort, J.

    1980-01-01

    This paper summarizes our recent results supporting the hypothesis that different regulation mechanisms are involved in the control of AHH and EH activity and that the AHH induction in the extrahepatic tissues might also be affected by liver specific inducers. In the rat, lung and kidney AHH is highly sensitive to the inducers present in cigarette smoke and cigarette smoke condensate, the EH activity not being affected by the same agents. Phenobarbital is also able to protentiate the inducing action of low doses of benzo(a)pyrene on the lung AHH activity. In primary rat liver cells in culture, AHH and EH can be selectivly induced. Low doses of benz(a)anthracene preferentially enhance the AHH activity while trans-stilbene oxide an various antioxidants modify only the EH activity. Phenobarbital, which also induces the AHH activity in cell culture, produces a more than additive effect when added to the culture medium in a mixture with benz(a)anthracene. Trans-stilbene oxide prevents the AHH induction by phenobarbital and not by benz(a)anthracene. Our results suggest that, in addition to its own induction capacity, phenobarbital is also able to potentiate the action of chemicals belonging to a different class of inducers.

  12. Acute, reproductive toxicity and two-generation teratology studies of a standardized quassinoid-rich extract of Eurycoma longifolia Jack in Sprague-Dawley rats.

    Science.gov (United States)

    Low, Bin-Seng; Das, Prashanta Kumar; Chan, Kit-Lam

    2014-07-01

    The roots of Eurycoma longifolia Jack are popularly sought as herbal medicinal supplements to improve libido and general health amongst the local ethnic population. The major quassinoids of E. longifolia improved spermatogenesis and fertility but toxicity studies have not been well documented. The reproductive toxicity, two generation of foetus teratology and the up-and-down acute toxicity were investigated in Sprague-Dawley rats orally treated with quassinoid-rich E. longifolia extract (TAF273). The results showed that the median lethal dose (LD50 ) of TAF273 for female and male rats was 1293 and >2000 mg/kg, respectively. Fertility index and litter size of the TAF273 treated were significantly increased when compared with those of the non-treated animals. The TAF273-treated dams decreased in percentage of pre-implantation loss, post-implantation loss and late resorption. No toxic symptoms were observed on the TAF273-treated pregnant female rats and their foetuses were normal. The no-observed adverse effect level (NOAEL) obtained from reproductive toxicity and teratology studies of TAF273 in rats was 100 mg/kg body weight/day, being more than 10-fold lower than the LD50 value. Thus, any human dose derived from converting the rat doses of 100 mg/kg and below may be considered as safe for further clinical studies. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Warfarin affects acute inflammatory response induced by subcutaneous polyvinyl sponge implantation in rats.

    Science.gov (United States)

    Mirkov, Ivana; Popov Aleksandrov, Aleksandra; Demenesku, Jelena; Ninkov, Marina; Mileusnic, Dina; Kataranovski, Dragan; Kataranovski, Milena

    2017-09-01

    Warfarin (WF) is an anticoagulant which also affects physiological processes other than hemostasis. Our previous investigations showed the effect of WF which gained access to the organism via skin on resting peripheral blood granulocytes. Based on these data, the aim of the present study was to examine whether WF could modulate the inflammatory processes as well. To this aim the effect of WF on the inflammatory response induced by subcutaneous sponge implantation in rats was examined. Warfarin-soaked polyvinyl sponges (WF-sponges) were implanted subcutaneously and cell infiltration into sponges, the levels of nitric oxide (NO) and inflammatory cytokines tumor necrosis factor (TNF) and interleukin-6 (IL-6) production by sponge cells were measured as parameters of inflammation. T cell infiltration and cytokine interferon-γ (IFN-γ), interleukin-17 (IL-17) and interleukin-10 (IL-10) were measured at day 7 post implantation. Warfarin exerted both stimulatory and suppressive effects depending on the parameter examined. Flow cytometry of cells recovered from sponges showed higher numbers of granulocytes (HIS48 + cells) at days 1 and 3 post implantation and CD11b + cells at day 1 compared to control sponges. Cells from WF-sponges had an increased NO production (Griess reaction) at days 1 and 7. In contrast, lower levels of TNF (measured by ELISA) production by cells recovered from WF-soaked sponges were found in the early (day one) phase of reaction with unchanged levels at other time points. While IL-6 production by cells recovered from WF-soaked sponges was decreased at day 1, it was increased at day 7. Higher T cell numbers were noted in WF sponges at day 7 post implantation, and recovered cells produced more IFN-γ and IL-17, while IL-10 production remained unchanged. Warfarin affects some of the parameters of inflammatory reaction induced by subcutaneous polyvinyl sponge implantation. Differential (both stimulatory as well as inhibitory) effects of WF on

  14. Radiation protection procedures and dose to the staff in brachytherapy with permanent implant of the sources

    International Nuclear Information System (INIS)

    Tosi, G.; Cattani, F.

    2002-01-01

    The treatment of intra capsular prostate cancers with the permanent implantation of low energy sealed radioactive sources (''103 Pd-''125I) offers the same probability of curing the tumours as surgery and external-beam radiotherapy with a minimum incidence of unwanted side-effects. The first attempts of using sealed sources for treating prostate cancers go back to 1917, when Barringer reported the results obtained with the implant of ''236Ra needles. Beginning from that period the interest for prostate brachytherapy has shown a fluctuating trend, due especially to the technological possibilities and to the status of the alternative treatment modalities (surgery, external radiotherapy). The main reason of the substantial failure of brachytherapy as compared to the two other treatment modalities had two main causes: the energy, too high ( E≅ 840 keV), of γ-radiation emitted by ''226 Ra in equilibrium with its decay products and the lack of imaging techniques able to visualize with sufficient accuracy both the prostate and the arrangement, inside it, of the radioactive sources. The employ of low energy γ-emitting radionuclides began in 1974, when Whitmore et al. working at the Sloan Kettering Memorial Cancer Hospital of New York suggested the use of ''125 I sealed sources for the realisation of interstitial permanent implants. Also this attempt, though reducing the side effects typical of the surgical intervention (incontinence, impotence), did non give the expected results in terms of local control of the disease and, as a consequence, of the survival's length. This partial failure was attributed to the fact that, in most cases the dose distribution inside the target volume was not homogeneous, due to the inadequacy of the available imaging techniques used for checking the real position of the sources, during their manual insertion in the tissues. In the last ten years,however, great progresses have been made in the US i maging techniques, in the manufacture of

  15. Plasma sheath physics and dose uniformity in enhanced glow discharge plasma immersion ion implantation and deposition

    International Nuclear Information System (INIS)

    Li Liuhe; Li Jianhui; Kwok, Dixon T. K.; Chu, Paul K.; Wang Zhuo

    2009-01-01

    Based on the multiple-grid particle-in-cell code, an advanced simulation model is established to study the sheath physics and dose uniformity along the sample stage in order to provide the theoretical basis for further improvement of enhanced glow discharge plasma immersion ion implantation and deposition. At t=7.0 μs, the expansion of the sheath in the horizontal direction is hindered by the dielectric cage. The electron focusing effect is demonstrated by this model. Most of the ions at the inside wall of the cage are implanted into the edge of the sample stage and a relatively uniform ion fluence distribution with a large peak is observed at the end. Compared to the results obtained from the previous model, a higher implant fluence and larger area of uniformity are disclosed.

  16. Hypofractionated stereotactic radiotherapy to the rat hippocampus. Determination of dose response and tolerance

    International Nuclear Information System (INIS)

    Ernst-Stecken, A.; Roedel, F.; Grabenbauer, G.; Sauer, R.; Jeske, I.; Bluemcke, I.; Hess, A.; Ganslandt, O.; Brune, K.

    2007-01-01

    Purpose: To determine the effect of hypofractionated stereotactic radiotherapy (hfSRT) on adult rat brain tissue (necrosis, impact on blood-brain barrier, signal changes on high-field magnetic resonance imaging [MRI]). Material and Methods: Adult male Wistar rats underwent MRI and CT scanning of the brain and respective images were introduced into the Novalis trademark radiosurgery device (BrainLab, Feldkirchen, Germany). All animals (body weight 350 g) were irradiated weekly with doses of 2 x 10 Gy (n = 3 animals), 3 x 10 Gy (n = 3 animals) and 4 x 10 Gy (n = 3 animals), targeted to the left hippocampus after image-guided positioning. 4.7-T T2-weighted MRI scanning was performed in each animal. Animals were sacrificed 8, 12, and 16 weeks after hfSRT and brains were immersion-fixed in 4% paraformaldehyde for subsequent histopathologic analysis. Results: In concordance with isodose distributions, pathologic signal hyperintensities in MRI were recorded from 4 x 10 Gy after 8 weeks, 3 x 10 Gy after 12 weeks, while 2 x 10 Gy induced slight detectable alterations only after 16 weeks. Subsequent histopathologic analysis revealed hippocampal cell necrosis with significantly earlier and stronger occurrence for higher doses (40 Gy > 30 Gy > 20 Gy). Pial microvessel permeability also increased after 40 Gy, whereas 30 Gy induced moderate changes. Conclusion: Conclusion: Partial-brain irradiation with hfSRT (Novalis trademark System) was successfully adopted for small animals and histopathologic analysis confirmed its repositioning accuracy. The neuropathologic effects correlated with dose and observation time. The approach will be further developed for quality assurance in hfSRT of normal brain tissue, as well as novel treatment modalities in epileptic rats and orthotopic tumor models. (orig.)

  17. The effects of nicotine injection in rat nucleus accumbens on anxiety

    Directory of Open Access Journals (Sweden)

    Ghorbani Yekta B

    2013-05-01

    Full Text Available Background: Previous reports showed that nucleus accumbens involved in the etiology and pathophysiology of major depression, anxiety and addiction. It is not clear that how these mechanisms occur in the brain. In the present study, the influence of direct nicotine injection in the nucleus accumbens in rats’ anxiety-related behavior was investigated. Methods: Wistar rats were used in this study. Male Wistar rats bred in an animal house, in a temperature-controlled (22±2 ◦C room with a 12 hour light/darkcycle. Rats were anesthetized using intraperitoneal injection of ketamine hydrochloride and xylazine, then placed in an stereotactic instrument for microinjection cannula implantation The stainless steel guide cannula was implanted bilaterally in the right and left dorsal the nucleus accumbens shell according to Paxinos and Watson atlas. After recovery, anxiety behavior and locomotor activity were tested. We used the elevated plus maze to test anxiety. This apparatus has widely been employed to test parameters of anxiety-related behaviors including the open armtime percentage (%OAT, open arm entries percentage (%OAE, locomotor activity and we record effect of drugs after injection directly in the nucleus accumbens on anxiety-related behavior.Results: Experiments showed that bilateral injections into the nucleus accumbens Nicotine, acetylcholine receptor agonist, dose 0.1 of the dose (0.05 and 0.1, 0.25, 0.5 microgram per rat caused a significant increase in the percentage of time spent in the open arms (%OAT, compared to the control group. We did not record any significant change locomotor activity and open arm entries percentage (%OAE in rats.Conclusion: Nicotinic receptors in the nucleus accumbens shell involved to anxiety-like behavior in male rats.

  18. Ion implantation of boron in germanium

    International Nuclear Information System (INIS)

    Jones, K.S.

    1985-05-01

    Ion implantation of 11 B + into room temperature Ge samples leads to a p-type layer prior to any post implant annealing steps. Variable temperature Hall measurements and deep level transient spectroscopy experiments indicate that room temperature implantation of 11 B + into Ge results in 100% of the boron ions being electrically active as shallow acceptor, over the entire dose range (5 x 10 11 /cm 2 to 1 x 10 14 /cm 2 ) and energy range (25 keV to 100 keV) investigated, without any post implant annealing. The concentration of damage related acceptor centers is only 10% of the boron related, shallow acceptor center concentration for low energy implants (25 keV), but becomes dominant at high energies (100 keV) and low doses ( 12 /cm 2 ). Three damage related hole traps are produced by ion implantation of 11 B + . Two of these hole traps have also been observed in γ-irradiated Ge and may be oxygen-vacancy related defects, while the third trap may be divacancy related. All three traps anneal out at low temperatures ( 0 C). Boron, from room temperature implantation of BF 2 + into Ge, is not substitutionally active prior to a post implant annealing step of 250 0 C for 30 minutes. After annealing additional shallow acceptors are observed in BF 2 + implanted samples which may be due to fluorine or flourine related complexes which are electrically active

  19. High-temperature Au implantation into Ni-Be and Ni-Si alloys

    Science.gov (United States)

    James, M. R.; Lam, N. Q.; Rehn, L. E.; Baldo, P. M.; Funk, L.; Stubbins, J. F.

    1992-12-01

    Effects of implantation temperature and target composition on depth distribution of implanted species were investigated. Au+ ions were implanted at 300 keV into polycrystalline Ni-Be and Ni-Si alloys between 25 and 700C to a dose of 10(exp 16) cm(exp -2). Depth distributions of Au were analyzed with RBS using He+ at both 1.7 and 3.0 MeV, and those of the other alloying elements by SIMS. Theoretical modeling of compositional redistribution during implantation at elevated temperatures was also carried out with the aid of a comprehensive kinetic model. The analysis indicated that below approximately 250C, the primary controlling processes were preferential sputtering and displacement mixing, while between 250 and 600C radiation-induced segregation was dominant. Above 600C, thermal-diffusion effects were most important. Fitting of model calculations to experimental measurements provided values for various defect migration and formation parameters.

  20. Histological and radiographic evaluation of the muscle tissue of rats after implantation of bone morphogenic protein (rhBMP-2 in a scaffold of inorganic bone and after stimulation with low-power laser light

    Directory of Open Access Journals (Sweden)

    Bengtson Antonio

    2010-01-01

    Full Text Available Objective: The present study histologically and radiologically evaluates the muscle tissue of rats after implantation of bone morphogenic protein (rhBMP-2 in a natural inorganic bone mineral scaffold from a bull calf femur and irradiation with low-power light laser. Materials and Methods: The right and left hind limbs of 16 rats were shaved and an incision was made in the muscle on the face corresponding to the median portion of the tibia, into which rhBMP-2 in a scaffold of inorganic bone was implanted. Two groups of limbs were formed: control (G1 and laser irradiation (G2. G2 received diode laser light applied in the direction of the implant, at a dose of 8 J/cm2 for three minutes. On the 7th, 21st, 40th and 112th days after implantation, hind limbs of 4 animals were radiographed and their implants removed together with the surrounding tissue for study under the microscope. The histological results were graded as 0=absence, 1=slight presence, 2=representative and 3=very representative, with regard to the following events: formation of osteoid structure, acute inflammation, chronic inflammation, fibrin deposition, neovascularization, foreign-body granuloma and fibrosis. Results: There were no statistically significant differences in these events at each evaluation times, between the two groups (P > 0.05; Mann-Whitney test. Nevertheless, it could be concluded that the natural inorganic bone matrix with rhBMP-2, from the femur of a bull calf, is a biocompatible combination. Conclusions: Under these conditions, the inductive capacity of rhBMP-2 for cell differentiation was inhibited. There was a slight acceleration in tissue healing in the group that received irradiation with low-power laser light.