  1. Cost Minimization Analysis of the Use of Meropenem and Ceftazidime in Febrile Neutropenia Therapy

    Directory of Open Access Journals (Sweden)

    Rizky Abdulah

    2016-06-01

    Full Text Available Use of antibiotics is required in febrile neutropenia therapy. The variety choice on the use of antibiotics has increased the role of pharmacoeconomics study to determine the most effective and efficient antibiotic in a specific area. The purpose of this study was to investigate the lowest cost antibiotic between meropenem and ceftazidime that were used as one of febrile neutropenia treatments at one of referral hospitals in West Java province during 2011–2013. This study was a retrospective, observational and analytical study that was performed on February 2014 by collecting medical record data related to febrile neutropenia inpatient who received meropenem or ceftazidime therapy. The result showed that although it was not statistically significant, the total cost for ceftazidime therapy was IDR7,082,523, which was lower than meropenem therapy (IDR11,094,147. Hopefully, this result can assist the health professionals in the management of febrile neutropenia therapy.

  2. Spatiotemporal pharmacodynamics of meropenem- and tobramycin-treated Pseudomonas aeruginosa biofilms

    DEFF Research Database (Denmark)

    Haagensen, Janus Anders Juul; Verotta, Davide; Huang, Liusheng

    2017-01-01

    The selection and dose of antibiotic therapy for biofilm-related infections are based on traditional pharmacokinetic studies using planktonic bacteria. The objective of this study was to characterize the time course and spatial activity of human exposure levels of meropenem and tobramycin against...... Pseudomonas aeruginosa biofilms grown in an in vitro flow-chamber model. Pharmacokinetic profiles of meropenem and tobramycin used in human therapy were administered to GFP-labelled P. aeruginosa PAO1 grown in flow chambers for 24 or 72 h. Images were acquired using confocal laser scanning microscopy...... throughout antibiotic treatment. Bacterial biomass was measured using COMSTAT and pharmacokinetic/pharmacodynamic models were fitted using NONMEM7. Meropenem treatment resulted in more rapid and sustained killing of both the 24 and 72 h PAO1 biofilm compared with tobramycin. Biofilm regrowth after antibiotic...

  3. Role of renal function in risk assessment of target non-attainment after standard dosing of meropenem in critically ill patients: a prospective observational study.

    Science.gov (United States)

    Ehmann, Lisa; Zoller, Michael; Minichmayr, Iris K; Scharf, Christina; Maier, Barbara; Schmitt, Maximilian V; Hartung, Niklas; Huisinga, Wilhelm; Vogeser, Michael; Frey, Lorenz; Zander, Johannes; Kloft, Charlotte

    2017-10-21

    Severe bacterial infections remain a major challenge in intensive care units because of their high prevalence and mortality. Adequate antibiotic exposure has been associated with clinical success in critically ill patients. The objective of this study was to investigate the target attainment of standard meropenem dosing in a heterogeneous critically ill population, to quantify the impact of the full renal function spectrum on meropenem exposure and target attainment, and ultimately to translate the findings into a tool for practical application. A prospective observational single-centre study was performed with critically ill patients with severe infections receiving standard dosing of meropenem. Serial blood samples were drawn over 4 study days to determine meropenem serum concentrations. Renal function was assessed by creatinine clearance according to the Cockcroft and Gault equation (CLCR CG ). Variability in meropenem serum concentrations was quantified at the middle and end of each monitored dosing interval. The attainment of two pharmacokinetic/pharmacodynamic targets (100%T >MIC , 50%T >4×MIC ) was evaluated for minimum inhibitory concentration (MIC) values of 2 mg/L and 8 mg/L and standard meropenem dosing (1000 mg, 30-minute infusion, every 8 h). Furthermore, we assessed the impact of CLCR CG on meropenem concentrations and target attainment and developed a tool for risk assessment of target non-attainment. Large inter- and intra-patient variability in meropenem concentrations was observed in the critically ill population (n = 48). Attainment of the target 100%T >MIC was merely 48.4% and 20.6%, given MIC values of 2 mg/L and 8 mg/L, respectively, and similar for the target 50%T >4×MIC . A hyperbolic relationship between CLCR CG (25-255 ml/minute) and meropenem serum concentrations at the end of the dosing interval (C 8h ) was derived. For infections with pathogens of MIC 2 mg/L, mild renal impairment up to augmented renal function was

  4. Adverse events associated with meropenem versus imipenem/cilastatin therapy in a large retrospective cohort of hospitalized infants.

    Science.gov (United States)

    Hornik, Christoph P; Herring, Amy H; Benjamin, Daniel K; Capparelli, Edmund V; Kearns, Gregory L; van den Anker, John; Cohen-Wolkowiez, Michael; Clark, Reese H; Smith, P Brian

    2013-07-01

    Carbapenems are commonly used in hospitalized infants despite a lack of complete safety data and associations with seizures in older children. We compared the incidence of adverse events in hospitalized infants receiving meropenem versus imipenem/cilastatin. We conducted a retrospective cohort study of 5566 infants treated with meropenem or imipenem/cilastatin in neonatal intensive care units managed by the Pediatrix Medical Group between 1997 and 2010. Multivariable conditional logistic regression was performed to evaluate the association between carbapenem therapy and adverse events, controlling for infant factors and severity of illness. Adverse events were more common with use of meropenem compared with imipenem/cilastatin (62.8/1000 infant days versus 40.7/1000 infant days, P imipenem/cilastatin (adjusted odds ratio 0.96; 95% confidence interval: 0.68, 1.32). The incidence of death, as well as the combined outcome of death or seizure, was lower with meropenem use-odds ratio 0.68 (0.50, 0.88) and odds ratio 0.77 (0.62, 0.95), respectively. In this cohort of infants, meropenem was associated with more frequent but less severe adverse events when compared with imipenem/cilastatin.

  5. Compatibility of Meropenem with Different Commercial Peritoneal Dialysis Solutions.

    Science.gov (United States)

    Wiesholzer, Martin; Winter, Alexandra; Kussmann, Manuel; Zeitlinger, Markus; Pichler, Petra; Burgmann, Heinz; Reznicek, Gottfried; Poeppl, Wolfgang

    ♦ BACKGROUND: Intraperitoneal administration of antimicrobial agents is recommended for the treatment of peritoneal dialysis (PD)-related peritonitis. For home-based antimicrobial therapy it is common to supply patients with PD fluid bags with admixed antibiotic. Thus, the compatibility of meropenem with different PD fluids (PDFs), namely Extraneal, Physioneal 1.36% and Physioneal 2.27% (all Baxter Healthcare Corp., Deerfield, IL, USA), was investigated under varying storage conditions. ♦ METHODS: Meropenem (Venus Pharma, Werne, Germany) was stored at 6°C and 25°C over 14 days and at 37°C over 24 hours. Drug concentration over time was determined using high performance liquid chromatography, drug activity by a diffusion disk method, diluent stability by visual inspection and drug adsorption was calculated. Blank PD fluids and deionized water were used as comparator solutions. ♦ RESULTS: Compared to water, the stability of meropenem was minimally lower in Extraneal but markedly reduced in both Physioneal solutions. No significant drug adsorption was detected for any PDF investigated. ♦ CONCLUSIONS: Meropenem is stable and compatible with Extraneal and might be stored for up to a week at refrigeration temperature (6°C). A loss of ~20% of meropenem after 2 days at room temperature should be considered. Mixed Physioneal appears not suitable for storage at any temperature after meropenem has been admixed. A considerable drug degradation due to the warming up to body temperature through heating plates should further be taken into account in clinical practice. Copyright © 2017 International Society for Peritoneal Dialysis.

  6. Antibiotic Dosing in Continuous Renal Replacement Therapy.

    Science.gov (United States)

    Shaw, Alexander R; Mueller, Bruce A

    2017-07-01

    Appropriate antibiotic dosing is critical to improve outcomes in critically ill patients with sepsis. The addition of continuous renal replacement therapy makes achieving appropriate antibiotic dosing more difficult. The lack of continuous renal replacement therapy standardization results in treatment variability between patients and may influence whether appropriate antibiotic exposure is achieved. The aim of this study was to determine if continuous renal replacement therapy effluent flow rate impacts attaining appropriate antibiotic concentrations when conventional continuous renal replacement therapy antibiotic doses were used. This study used Monte Carlo simulations to evaluate the effect of effluent flow rate variance on pharmacodynamic target attainment for cefepime, ceftazidime, levofloxacin, meropenem, piperacillin, and tazobactam. Published demographic and pharmacokinetic parameters for each antibiotic were used to develop a pharmacokinetic model. Monte Carlo simulations of 5000 patients were evaluated for each antibiotic dosing regimen at the extremes of Kidney Disease: Improving Global Outcomes guidelines recommended effluent flow rates (20 and 35 mL/kg/h). The probability of target attainment was calculated using antibiotic-specific pharmacodynamic targets assessed over the first 72 hours of therapy. Most conventional published antibiotic dosing recommendations, except for levofloxacin, reach acceptable probability of target attainment rates when effluent rates of 20 or 35 mL/kg/h are used. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  7. Pharmacokinetics of meropenem after intravenous, intramuscular and subcutaneous administration to cats.

    Science.gov (United States)

    Albarellos, Gabriela A; Montoya, Laura; Passini, Sabrina M; Lupi, Martín P; Lorenzini, Paula M; Landoni, María F

    2016-12-01

    The aim of the study was to describe the pharmacokinetics and predicted efficacy of meropenem after intravenous (IV), intramuscular (IM) and subcutaneous (SC) administration to cats at a single dose of 10 mg/kg. Five adult healthy cats were used. Blood samples were withdrawn at predetermined times over a 12 h period. Meropenem concentrations were determined by microbiological assay. Pharmacokinetic analyses were performed with computer software. Initial estimates were determined using the residual method and refitted by non-linear regression. The time that plasma concentrations were greater than the minimum inhibitory concentration (T >MIC) was estimated by applying bibliographic MIC values and meropenem MIC breakpoint. Maximum plasma concentrations of meropenem were 101.02 µg/ml (C p(0) , IV), 27.21 µg/ml (C max , IM) and 15.57 µg/ml (C max , SC). Bioavailability was 99.69% (IM) and 96.52 % (SC). Elimination half-lives for the IV, IM and SC administration were 1.35, 2.10 and 2.26 h, respectively. Meropenem, when administered to cats at a dose of 10 mg/kg q12h,, is effective against bacteria with MIC values of 6 μg/ml, 7 μg/ml and 10 μg/ml for IV, IM and SC administration, respectively. However, clinical trials are necessary to confirm clinical efficacy of the proposed dosage regimen. © The Author(s) 2015.

  8. Cefozopran, meropenem, or imipenem-cilastatin compared with cefepime as empirical therapy in febrile neutropenic adult patients: A multicenter prospective randomized trial.

    Science.gov (United States)

    Nakane, Takahiko; Tamura, Kazuo; Hino, Masayuki; Tamaki, Toshiharu; Yoshida, Isao; Fukushima, Toshihiro; Tatsumi, Youichi; Nakagawa, Yasuaki; Hatanaka, Kazuo; Takahashi, Tsutomu; Akiyama, Nobu; Tanimoto, Mitsune; Ohyashiki, Kazuma; Urabe, Akio; Masaoka, Toru; Kanamaru, Akihisa

    2015-01-01

    We conducted an open-label, randomized study to evaluate the clinical efficacy of cefozopran, meropenem or imipenem-cilastatin using cefepime as a control in febrile neutropenia (FN) patients. Three hundred and seventy-six patients received cefepime, cefozopran, meropenem or imipenem-cilastatinas initial therapy for FN. The primary endpoint was the non-inferiority of response rates including modification at day 7 in cefozopran, meropenem or imipenem-cilastatin patients compared with cefepime in the per-protocol population (delta = 10%). The response rates for cefozopran, meropenem and imipenem-cilastatin were not significantly different compared with cefepime (cefozopran: 54/90 (60%), meropenem: 60/92 (65%), and IPM/CS: 63/88 (72%) versus cefepime: 56/85 (66%) (p = 0.44, 1.0 and 0.51, respectively)), and the differences in treatment success for cefozopran, meropenem and imipenem-cilastatin compared with cefepime were -5.9% (95% confidence interval (CI): -20.1-8.4), -0.7% (95% CI: -14.6-13.3), and 5.7% (95% CI: -8.1-19.4), respectively. The same tendency was seen in the modified intention-to-treat population. Based on the evaluation of initial drug efficacy performed on days 3-5, there was no significant difference between the four drugs. In the subgroup with an absolute neutrophil count ≤ 100 × 10(6)/L for longer than seven days, there was significantly better efficacy in the carbapenem arm compared to 4th generation beta-lactams (52% versus 27% at days 3-5, p = 0.006, and 76% versus 48% at day 7, p = 0.002). Our results suggest that the effects of these four drugs as empiric therapy were virtually the same for adult FN patients, although non-inferiority was shown only in imipenem-cilastatin compared with cefepime (clinical trial number: UMIN000000462). Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  9. Meropenem and Vaborbactam Injection

    Science.gov (United States)

    ... is in a class of medications called carbapenem antibiotics. It works by killing bacteria. Vaborbactam is in a class ... It works by preventing bacteria from destroying meropenem.Antibiotics such as meropenem and vaborbactam injection will not work for colds, flu, or other viral infections. Taking ...

  10. Additivity vs Synergism: Investigation of the Additive Interaction of Cinnamon Bark Oil and Meropenem in Combinatory Therapy.

    Science.gov (United States)

    Yang, Shun-Kai; Yusoff, Khatijah; Mai, Chun-Wai; Lim, Wei-Meng; Yap, Wai-Sum; Lim, Swee-Hua Erin; Lai, Kok-Song

    2017-11-04

    Combinatory therapies have been commonly applied in the clinical setting to tackle multi-drug resistant bacterial infections and these have frequently proven to be effective. Specifically, combinatory therapies resulting in synergistic interactions between antibiotics and adjuvant have been the main focus due to their effectiveness, sidelining the effects of additivity, which also lowers the minimal effective dosage of either antimicrobial agent. Thus, this study was undertaken to look at the effects of additivity between essential oils and antibiotic, via the use of cinnamon bark essential oil (CBO) and meropenem as a model for additivity. Comparisons between synergistic and additive interaction of CBO were performed in terms of the ability of CBO to disrupt bacterial membrane, via zeta potential measurement, outer membrane permeability assay and scanning electron microscopy. It has been found that the additivity interaction between CBO and meropenem showed similar membrane disruption ability when compared to those synergistic combinations which was previously reported. Hence, results based on our studies strongly suggest that additive interaction acts on a par with synergistic interaction. Therefore, further investigation in additive interaction between antibiotics and adjuvant should be performed for a more in depth understanding of the mechanism and the impacts of such interaction.

  11. Additivity vs Synergism: Investigation of the Additive Interaction of Cinnamon Bark Oil and Meropenem in Combinatory Therapy

    Directory of Open Access Journals (Sweden)

    Shun-Kai Yang

    2017-11-01

    Full Text Available Combinatory therapies have been commonly applied in the clinical setting to tackle multi-drug resistant bacterial infections and these have frequently proven to be effective. Specifically, combinatory therapies resulting in synergistic interactions between antibiotics and adjuvant have been the main focus due to their effectiveness, sidelining the effects of additivity, which also lowers the minimal effective dosage of either antimicrobial agent. Thus, this study was undertaken to look at the effects of additivity between essential oils and antibiotic, via the use of cinnamon bark essential oil (CBO and meropenem as a model for additivity. Comparisons between synergistic and additive interaction of CBO were performed in terms of the ability of CBO to disrupt bacterial membrane, via zeta potential measurement, outer membrane permeability assay and scanning electron microscopy. It has been found that the additivity interaction between CBO and meropenem showed similar membrane disruption ability when compared to those synergistic combinations which was previously reported. Hence, results based on our studies strongly suggest that additive interaction acts on a par with synergistic interaction. Therefore, further investigation in additive interaction between antibiotics and adjuvant should be performed for a more in depth understanding of the mechanism and the impacts of such interaction.

  12. mcr-1 and blaKPC-3 in Escherichia coli Sequence Type 744 after Meropenem and Colistin Therapy, Portugal.

    Science.gov (United States)

    Tacão, Marta; Tavares, Rafael Dos Santos; Teixeira, Pedro; Roxo, Inês; Ramalheira, Elmano; Ferreira, Sónia; Henriques, Isabel

    2017-08-01

    Escherichia coli Ec36 was recovered from a patient in Portugal after treatment with meropenem and colistin. Besides an IncF plasmid with Tn1441d-bla KPC-3 , already reported in clinical strains in this country, E. coli Ec36 co-harbored an IncX4::mcr-1 gene. Results highlight emerging co-resistance to carbapenems and polymyxins after therapy with drugs from both classes.

  13. Population Pharmacokinetics of Meropenem in Plasma and Subcutis in Patients on Extracorporeal Membrane Oxygenation Treatment

    DEFF Research Database (Denmark)

    Hanberg, Pelle; Öbrink-Hansen, Kristina; Thorsted, Anders

    2018-01-01

    The objectives of this study were to describe meropenem pharmacokinetics (PK) in plasma and/or subcutaneous adipose tissue (SCT) in critically ill patients receiving ECMO treatment, and to develop a population PK model to simulate alternative dosing regimens and modes of administration. We...... conducted a prospective observational study. Ten patients on ECMO treatment received meropenem (1 or 2 g) intravenously over 5 min every 8 hours. Serial SCT concentrations were determined using microdialysis and compared with plasma concentrations. A population PK model of SCT and plasma data was developed...... infusion would be needed for 100%fT>MIC and 100%fT>4xMIC to be obtained. Meropenem plasma and SCT concentrations were associated with estimated creatinine-clearance (eCLCr). Simulations showed that in patients with increased eCLCr, dose increment or continuous infusion may be needed to obtain therapeutic...

  14. A young infant with transient severe hypertriglyceridemia temporarily associated with meropenem administration: A case report and review of the literature.

    Science.gov (United States)

    Esposito, Susanna; Pinzani, Raffaella; Raffaeli, Genny; Lucchi, Tiziano; Agostoni, Carlo; Principi, Nicola

    2016-09-01

    Slight changes in the lipid profile can be observed over the acute phase of infectious diseases. Moreover, some anti-infective drugs can modify serum lipid concentrations, although antibiotics do not seem to have a relevant, direct, or acute effect on the lipid profile. A 75-day-old breastfed Caucasian female, born at term after a regular pregnancy, was hospitalized for osteomyelitis. She was immediately treated with intravenous meropenem and vancomycin. Therapy was effective, but after 22 days of treatment, her blood was found to be viscous with a purple shade. A fasting blood sample showed serum triglycerides of 966 mg/dL, total cholesterol of 258 mg/dL, and high-density lipoprotein cholesterol of 15 mg/dL. Secondary causes of hyperlipidemia and primary hereditary disorders were ruled out. Thereafter, the possibility that antibiotics may have had a role in the hypertriglyceridemia was considered, and meropenem was discontinued. After 72 hours of meropenem discontinuation, a sharp modification of lipid variables was observed, and further testing showed a complete normalization of the lipid profile. In this child with osteomyelitis, the increase in serum triglycerides appeared suddenly after 3 weeks of meropenem treatment and resolved quickly after meropenem discontinuation, thus highlighting the possible association between meropenem and lipid profile alterations. Monitoring the lipid profile should be considered in cases of long-term treatment with meropenem, and further studies on meropenem safety should include evaluation of the lipid profile.

  15. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  16. Microbiological assay for the determination of meropenem in pharmaceutical dosage form.

    Science.gov (United States)

    Mendez, Andreas S L; Weisheimer, Vanessa; Oppe, Tércio P; Steppe, Martin; Schapoval, Elfrides E S

    2005-04-01

    Meropenem is a highly active carbapenem antibiotic used in the treatment of a wide range of serious infections. The present work reports a microbiological assay, applying the cylinder-plate method, for the determination of meropenem in powder for injection. The validation method yielded good results and included linearity, precision, accuracy and specificity. The assay is based on the inhibitory effect of meropenem upon the strain of Micrococcus luteus ATCC 9341 used as the test microorganism. The results of assay were treated statistically by analysis of variance (ANOVA) and were found to be linear (r=0.9999) in the range of 1.5-6.0 microg ml(-1), precise (intra-assay: R.S.D.=0.29; inter-assay: R.S.D.=0.94) and accurate. A preliminary stability study of meropenem was performed to show that the microbiological assay is specific for the determination of meropenem in the presence of its degradation products. The degraded samples were also analysed by the HPLC method. The proposed method allows the quantitation of meropenem in pharmaceutical dosage form and can be used for the drug analysis in routine quality control.

  17. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  18. In Vivo Efficacy of Plazomicin Alone or in Combination with Meropenem or Tigecycline against Enterobacteriaceae Isolates Exhibiting Various Resistance Mechanisms in an Immunocompetent Murine Septicemia Model.

    Science.gov (United States)

    Abdelraouf, Kamilia; Kim, Aryun; Krause, Kevin M; Nicolau, David P

    2018-06-04

    Background : Plazomicin is a next-generation aminoglycoside with potent in vitro activity against multidrug- and carbapenem-resistant Enterobacteriaceae. The objective of this study was to assess the efficacy of plazomicin exposure, alone and in combination with meropenem or tigecycline, against Enterobacteriaceae in the immunocompetent murine septicemia model. Methods : ICR mice were inoculated intraperitoneally with bacterial suspensions. Eight Enterobacteriaceae isolates with wide ranges of plazomicin, meropenem and tigecycline MICs were utilized. Treatment mice were administered plazomicin, meropenem or tigecycline human-equivalent doses alone or in combinations of plazomicin/meropenem and plazomicin/tigecycline. Treatments were initiated 1h post-infection and continued for 24h. Efficacy was assessed by survival through 96h. Results : Compared with controls, plazomicin monotherapy produced significant improvement in survival for all isolates (P32 and 2 mg/L, respectively), combination therapies showed significant reduction in mortality compared with any monotherapy (P<0.05). Conclusion : Plazomicin monotherapy resulted in improved survival in the immunocompetent murine septicemia model, notably for isolates with plazomicin MIC ≤4 mg/L. As evidenced by our current data, co-administration of meropenem or tigecycline could potentially lead to further improvement in survival. These data support a role for plazomicin in the management of septicemia due to Enterobacteriaceae with plazomicin MIC ≤4 mg/L, including carbapenem-resistant isolates. Copyright © 2018 American Society for Microbiology.

  19. High dose therapy with autologous stem cell support in malignant disorders

    International Nuclear Information System (INIS)

    Holte, H.; Kvaloey, S.O.; Engan, T.

    1996-01-01

    New biomedical knowledge may improve the diagnostic procedures and treatment provided by the Health Services, but at additional cost. In a social democratic health care system, the hospital budgets have no room for expensive, new procedures or treatments, unless these are funded through extra allocation from the central authorities. High dose therapy with autologous stem cell support in malignant disorders is an example of a new and promising, but rather expensive treatment, but its role in cancer therapy has yet to be established. The indications for testing high dose therapy with autologous stem cell support in various malignancies are discussed, with emphasis on the principles for deciding which categories of disease should have priority. The authors suggest some malignant disorder for which high dose therapy with stem cell support should be explored versus conventional treatment in randomized prospective trials. 8 refs., 1 tab

  20. The Role of High Dose Interleukin-2 in the Era of Targeted Therapy.

    Science.gov (United States)

    Gills, Jessie; Parker, William P; Pate, Scott; Niu, Sida; Van Veldhuizen, Peter; Mirza, Moben; Holzbeierlein, Jeffery M; Lee, Eugene K

    2017-09-01

    We assessed survival outcomes following high dose interleukin-2 in a contemporary cohort of patients during the era of targeted agents. We retrospectively reviewed the records of patients with metastatic renal cell carcinoma treated with high dose interleukin-2 between July 2007 and September 2014. Clinicopathological data were abstracted and patient response to therapy was based on RECIST (Response Evaluation Criteria In Solid Tumors), version 1.1 criteria. The Kaplan-Meier method was used to estimate progression-free and overall survival in the entire cohort, the response to high dose interleukin-2 in regard to previous targeted agent therapy and the response to the targeted agent in relation to the response to high dose interleukin-2. We identified 92 patients, of whom 87 had documentation of a response to high dose interleukin-2. Median overall survival was 34.4 months from the initiation of high dose interleukin-2 therapy in the entire cohort. Patients who received targeted therapy before high dose interleukin-2 had overall survival (median 34.4 and 30.0 months, p = 0.88) and progression-free survival (median 1.5 and 1.7 months, p = 0.8) similar to those in patients who received no prior therapy, respectively. Additionally, patients with a complete or partial response to high dose interleukin-2 had similar outcomes for subsequent targeted agents compared to patients whose best response was stable or progressive disease (median overall survival 30.1 vs 25.4 months, p = 0.4). Our data demonstrate that patient responses to high dose interleukin-2 and to targeted agents before and after receiving high dose interleukin-2 are independent. As such, carefully selected patients should be offered high dose interleukin-2 for the possibility of a complete and durable response without the fear of limiting the treatment benefit of targeted agents. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Assessments for high dose radionuclide therapy treatment planning

    International Nuclear Information System (INIS)

    Fisher, D.R.

    2003-01-01

    Advances in the biotechnology of cell specific targeting of cancer and the increased number of clinical trials involving treatment of cancer patients with radiolabelled antibodies, peptides, and similar delivery vehicles have led to an increase in the number of high dose radionuclide therapy procedures. Optimised radionuclide therapy for cancer treatment is based on the concept of absorbed dose to the dose limiting normal organ or tissue. The limiting normal tissue is often the red marrow, but it may sometimes be the lungs, liver, intestinal tract, or kidneys. Appropriate treatment planning requires assessment of radiation dose to several internal organs and tissues, and usually involves biodistribution studies in the patient using a tracer amount of radionuclide bound to the targeting agent and imaged at sequential timepoints using a planar gamma camera. Time-activity curves are developed from the imaging data for the major organ tissues of concern, for the whole body and sometimes for selected tumours. Patient specific factors often require that dose estimates be customised for each patient. In the United States, the Food and Drug Administration regulates the experimental use of investigational new drugs and requires 'reasonable calculation of radiation absorbed dose to the whole body and to critical organs' using the methods prescribed by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. Review of high dose studies shows that some are conducted with minimal dosimetry, that the marrow dose is difficult to establish and is subject to large uncertainties. Despite the general availability of software, internal dosimetry methods often seem to be inconsistent from one clinical centre to another. (author)

  2. High-dose radioiodine therapy of Graves disease

    International Nuclear Information System (INIS)

    Solodky, V.; Fomin, D.; Pestritskaya, E.

    2015-01-01

    Full text of publication follows. Objectives: to estimate the effectiveness and safety of the disease treatment under different modes of applying RIT. Materials and methods: 67 patients with the thyrotoxicosis condition associated with Graves disease were researched. The patients were divided into 2 groups: a control group with 25 people (18 women and 7 men), who underwent a low-dose therapy of 150-500 MBq; and a main group of 42 people (32 women and 10 men), who underwent a high-dose therapy of 550 and 800 MBq. The volume of thyroid prior to the treatment made up 23.8 ± 20 ml in the main group and 30.2 ± 23 ml in the control one. The average age in the high-dose group was 44.6 ±23 years old and in the low-dose -47.2 ± 24 years old. In terms of the hormone level before the RIT, 52% of the main group patients experienced euthyroidism, while 48% - thyrotoxicosis. The corresponding indices in the control group were 42% and 58% respectively. The cessation of the thyreostatic therapy came on 5. to 21. day prior to the treatment, with the average of 14 ±7 days in both groups. The diagnosis of the disease was based on ultrasonography, planar scintigraphy, the hormone level and antibody titer. The performance was assessed through the attainment of hypo-thyrosis and the transition to a substitutive hormonal therapy with L-thyroxine in 6 months or more. The attainment of euthyroidism was seen as a partial effect due to a possibility of relapse. Results: in 6 months a positive result in the form of hypo-thyrosis was achieved for 39 patients in the main group, which accounted for 93%, and 3 patients (7%) experienced euthyroidism. No symptomatic thyrotoxicosis relapses were revealed. In the control group, hypo-thyrosis was achieved by 18 patients, which accounted for 72%; euthyroidism came up to 12%; 4 patients needed a refresher course of RIT, which made up 16% of the group. 93% of the main group patients tolerated the treatment favourably. 3 patients complained of the

  3. Multifocal Electroretinography after High Dose Chloroquine Therapy for Malaria

    Directory of Open Access Journals (Sweden)

    Aline Correa de Carvalho

    2013-01-01

    Full Text Available Purpose: To investigate changes in multifocal electroretinography (mfERG parameters associated with high dose chloroquine therapy for treatment of malaria in the Amazonia region of Brazil. Methods: Forty-eight subjects who had received chloroquine treatment for single or multiple malaria infections with a cumulative dose ranging from 1,050 to 27,000mg were included. The control group consisted of 37 healthy aged-matched subjects. Data was collected on amplitude and implicit time of the N1, P1 and N2 waves in the central macular hexagon (R1 and in five concentric rings at different retinal eccentricities (R2-R6. Results: No significant difference was observed in any mfERG parameter between chloroquine treated patients and control subjects. A comparison with previous data obtained from patients with rheumatologic disorders in the same region of Brazil who had received larger cumulative doses of chloroquine and had displayed mfERG changes, indicated that retinal toxicity seems to be dependent on cumulative dose. Conclusion: Lack of mfERG changes in the current study suggests that intensive high dose chloroquine therapy for treatment of malaria is not associated with retinal toxicity.

  4. High-dose steroid therapy for idiopathic optic perineuritis: a case series

    Directory of Open Access Journals (Sweden)

    Mimura Tatsuya

    2010-12-01

    Full Text Available Abstract Introduction It has been reported that the prognosis of optic perineuritis may be poor when initiation of treatment is delayed. Here we report the successful treatment of three patients with idiopathic optic perineuritis, including two in whom initiation of therapy was delayed. Case presentation Three Japanese patients (two women aged 73 and 66 years, and one man aged 27 years presented with loss of vision (for five months, several months, and two months respectively and pain on eye movement in the third case only, and were diagnosed as having idiopathic optic perineuritis. Fat-suppressed T2-weighted magnetic resonance images showed high signal intensity areas around the affected optic nerves, suggesting the presence of optic perineuritis. Two patients received steroid pulse therapy and the third was given high-dose steroid therapy. The visual acuity improved in all three cases. Conclusion High-dose steroid therapy may be effective for idiopathic perineuritis in patients without optic nerve atrophy, even if initial treatment (including moderate-dose steroids has failed.

  5. Early Angiographic Resolution of Cerebral Vasospasm with High Dose Intravenous Milrinone Therapy

    Directory of Open Access Journals (Sweden)

    F. A. Zeiler

    2015-01-01

    Full Text Available Background. Treatment of symptomatic delayed cerebral ischemia (DCI after subarachnoid hemorrhage (SAH is difficult. Recent studies suggest intravenous (IV high dose milrinone as a potential therapy. The timing to angiographic response with this is unclear. Methods. We reviewed the chart of one patient admitted for SAH who developed symptomatic DCI and was treated with high dose IV milrinone. Results. A 66-year-old female was admitted with a Hunt and Hess clinical grade 4, World Federation of Neurological Surgeons (WFNS clinical grade 4, and SAH secondary to a left anterior choroidal artery aneurysm which was clipped. After bleed day 6, the patient developed symptomatic DCI. We planned for angioplasty of the proximal segments. We administered high dose IV milrinone bolus followed by continuous infusion which led to clinical improvement prior to angiography. The angiogram performed 1.5 hours after milrinone administration displayed resolution of the CT angiogram and MRI based cerebral vasospasm such that further intra-arterial therapy was aborted. She completed 6 days of continuous IV milrinone therapy, was transferred to the ward, and subsequently rehabilitated. Conclusions. High dose IV milrinone therapy for symptomatic DCI after SAH can lead to rapid neurological improvement with dramatic early angiographic improvement of cerebral vasospasm.

  6. Population Pharmacokinetics and Pharmacodynamics of Meropenem in Nonobese, Obese, and Morbidly Obese Patients.

    Science.gov (United States)

    Chung, Eun Kyoung; Cheatham, S Christian; Fleming, Megan R; Healy, Daniel P; Kays, Michael B

    2017-03-01

    The study objective was to evaluate meropenem population pharmacokinetics and pharmacodynamics in nonobese, obese, and morbidly obese patients. Forty adult patients-11 nonobese (body mass index [BMI] calculate probability of target attainment (PTA) for 5 dosing regimens, infused over 0.5 and 3 hours, using fT>MIC of 40%, 54%, and 100% of the dosing interval. A 2-compartment linear-elimination model best described the serum concentration-time data, and creatinine clearance was significantly associated with systemic clearance. Pharmacokinetic parameters were not significantly different among patient groups. In patients with creatinine clearances ≥50 mL/min, all simulated dosing regimens achieved >90% PTA at 40% fT>MIC in all patient groups at MICs ≤2 mg/L. Only 500 mg q8h, infused over 0.5 hour, did not achieve >90% PTA at 54% fT>MIC in nonobese and morbidly obese patients. At 100% fT>MIC, 1 g q6h and 2 g q8h, infused over 3 hours, reliably achieved >90% PTA in all patient groups. Meropenem pharmacokinetics are comparable among nonobese, obese, and morbidly obese patients. Standard dosing regimens provide adequate pharmacodynamic exposures for susceptible pathogens at 40% and 54% fT>MIC, but prolonged infusions of larger doses are needed for adequate exposures at 100% fT>MIC. Dosage adjustments based solely on body weight are unnecessary. © 2016, The American College of Clinical Pharmacology.

  7. Imipenem, meropenem, or doripenem to treat patients with Pseudomonas aeruginosa ventilator-associated pneumonia.

    Science.gov (United States)

    Luyt, Charles-Edouard; Aubry, Alexandra; Lu, Qin; Micaelo, Maïté; Bréchot, Nicolas; Brossier, Florence; Brisson, Hélène; Rouby, Jean-Jacques; Trouillet, Jean-Louis; Combes, Alain; Jarlier, Vincent; Chastre, Jean

    2014-01-01

    Only limited data exist on Pseudomonas aeruginosa ventilator-associated pneumonia (VAP) treated with imipenem, meropenem, or doripenem. Therefore, we conducted a prospective observational study in 169 patients who developed Pseudomonas aeruginosa VAP. Imipenem, meropenem, and doripenem MICs for Pseudomonas aeruginosa isolates were determined using Etests and compared according to the carbapenem received. Among the 169 isolates responsible for the first VAP episode, doripenem MICs were lower (Pimipenem and meropenem (MIC50s, 0.25, 2, and 0.38, respectively); 61%, 64%, and 70% were susceptible to imipenem, meropenem, and doripenem, respectively (P was not statistically significant). Factors independently associated with carbapenem resistance were previous carbapenem use (within 15 days) and mechanical ventilation duration before VAP onset. Fifty-six (33%) patients had at least one VAP recurrence, and 56 (33%) died. Factors independently associated with an unfavorable outcome (recurrence or death) were a high day 7 sequential organ failure assessment score and mechanical ventilation dependency on day 7. Physicians freely prescribed a carbapenem to 88 patients: imipenem for 32, meropenem for 24, and doripenem for 32. The remaining 81 patients were treated with various antibiotics. Imipenem-, meropenem-, and doripenem-treated patients had similar VAP recurrence rates (41%, 25%, and 22%, respectively; P=0.15) and mortality rates (47%, 25%, and 22%, respectively; P=0.07). Carbapenem resistance emerged similarly among patients treated with any carbapenem. No carbapenem was superior to another for preventing carbapenem resistance emergence.

  8. Radiation exposure for 'caregivers' during high-dose outpatient radioiodine therapy

    International Nuclear Information System (INIS)

    Marriott, C. J.; Webber, C. E.; Gulenchyn, K. Y.

    2007-01-01

    On 27 occasions, radiation doses were measured for a family member designated as the 'caregiver' for a patient receiving high-dose radioiodine outpatient therapy for differentiated thyroid carcinoma. For 25 of the administrations, patients received 3.7 GBq of 131 I. Radiation doses for the designated caregivers were monitored on an hourly basis for 1 week using electronic personal dosemeters. The average penetrating dose was 98±64 μSv. The maximum penetrating dose was 283 μSv. Measured dose rate profiles showed that, on average, one-third of the caregiver dose was received during the journey home from hospital. The mean dose rate profile showed rapid clearance of 131 I with three distinct phases. The corresponding clearance half-times were 131 I contaminating the home. (authors)

  9. Use of Monte Carlo Simulations to Determine Optimal Carbapenem Dosing in Critically Ill Patients Receiving Prolonged Intermittent Renal Replacement Therapy.

    Science.gov (United States)

    Lewis, Susan J; Kays, Michael B; Mueller, Bruce A

    2016-10-01

    Pharmacokinetic/pharmacodynamic analyses with Monte Carlo simulations (MCSs) can be used to integrate prior information on model parameters into a new renal replacement therapy (RRT) to develop optimal drug dosing when pharmacokinetic trials are not feasible. This study used MCSs to determine initial doripenem, imipenem, meropenem, and ertapenem dosing regimens for critically ill patients receiving prolonged intermittent RRT (PIRRT). Published body weights and pharmacokinetic parameter estimates (nonrenal clearance, free fraction, volume of distribution, extraction coefficients) with variability were used to develop a pharmacokinetic model. MCS of 5000 patients evaluated multiple regimens in 4 different PIRRT effluent/duration combinations (4 L/h × 10 hours or 5 L/h × 8 hours in hemodialysis or hemofiltration) occurring at the beginning or 14-16 hours after drug infusion. The probability of target attainment (PTA) was calculated using ≥40% free serum concentrations above 4 times the minimum inhibitory concentration (MIC) for the first 48 hours. Optimal doses were defined as the smallest daily dose achieving ≥90% PTA in all PIRRT combinations. At the MIC of 2 mg/L for Pseudomonas aeruginosa, optimal doses were doripenem 750 mg every 8 hours, imipenem 1 g every 8 hours or 750 mg every 6 hours, and meropenem 1 g every 12 hours or 1 g pre- and post-PIRRT. Ertapenem 500 mg followed by 500 mg post-PIRRT was optimal at the MIC of 1 mg/L for Streptococcus pneumoniae. Incorporating data from critically ill patients receiving RRT into MCS resulted in markedly different carbapenem dosing regimens in PIRRT from those recommended for conventional RRTs because of the unique drug clearance characteristics of PIRRT. These results warrant clinical validation. © 2016, The American College of Clinical Pharmacology.

  10. Activity of Colistin in Combination with Meropenem, Tigecycline, Fosfomycin, Fusidic Acid, Rifampin or Sulbactam against Extensively Drug-Resistant Acinetobacter baumannii in a Murine Thigh-Infection Model.

    Directory of Open Access Journals (Sweden)

    Bing Fan

    Full Text Available Few effective therapeutic options are available for treating severe infections caused by extensively drug-resistant Acinetobacter baumannii (XDR-AB. Using a murine thigh-infection model, we examined the in vivo efficacy of colistin in combination with meropenem, tigecycline, fosfomycin, fusidic acid, rifampin, or sulbactam against 12 XDR-AB strains. Colistin, tigecycline, rifampin, and sulbactam monotherapy significantly decreased bacterial counts in murine thigh infections compared with those observed in control mice receiving no treatment. Colistin was the most effective agent tested, displaying bactericidal activity against 91.7% of strains at 48 h post-treatment. With strains showing a relatively low minimum inhibitory concentration (MIC for meropenem (MIC ≤ 32 mg/L, combination therapy with colistin plus meropenem caused synergistic inhibition at both 24 h and 48 h post-treatment. However, when the meropenem MIC was ≥64 mg/L, meropenem did not significantly alter the efficacy of colistin. The addition of rifampin and fusidic acid significantly improved the efficacy of colistin, showing a synergistic effect in 100% and 58.3% of strains after 24 h of treatment, respectively, while the addition of tigecycline, fosfomycin, or sulbactam did not show obvious synergistic activity. No clear differences in activities were observed between colistin-rifampin and colistin-fusidic acid combination therapy with most strains. Overall, our in vivo study showed that administering colistin in combination with rifampin or fusidic acid is more efficacious in treating XDR-AB infections than other combinations. The colistin-meropenem combination may be another appropriate option if the MIC is ≤32 mg/L. Further clinical studies are urgently needed to confirm the relevance of these findings.

  11. Split high-dose oral levothyroxine treatment as a successful therapy option in myxedema coma.

    Science.gov (United States)

    Charoensri, Suranut; Sriphrapradang, Chutintorn; Nimitphong, Hataikarn

    2017-10-01

    High-dose intravenous thyroxine (T4) is the preferable treatment for myxedema coma. We describe the clinical course of a 69-year-old man who presented with myxedema coma and received oral levothyroxine (LT4) therapy (1 mg) in a split dose. This suggests split high-dose oral LT4 as a therapeutic option in myxedema coma.

  12. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  13. [High-dosed gestagen therapy of the metastatic mammary carcinoma (author's transl)].

    Science.gov (United States)

    Firusian, N; Becher, R

    1981-12-01

    Thirty patients with histologically proven metastatic mammary carcinoma were treated, after exhaustion of hormonal and cytostatic therapeutic means, with high-dosed medroxyprogesterone acetate (MPA) during a ten-day induction phase with 1000 mg MPAi.m. per day and then with 600 mg oral MPA per day. In eleven patients a complete or partial remission was achieved. The median period of remission comprised ten months. A positive relationship was found between the response to high-dosed MPA therapy and the length of free intervals. Side effects were tolerable.

  14. A Retrospective Study on the Incidence of Seizures among Neurosurgical Patients Who Treated with Imipenem/Cilastatin or Meropenem.

    Science.gov (United States)

    Wu, Yuanxing; Chen, Kai; Shi, Zhonghua; Wang, Qiang

    2014-01-01

    We sought to evaluate the safety of imipenem and meropenem in the treatment of infections in neurosurgical patients. An observational retrospective study was conducted of consecutive cases treated with imipenem from Sept. 2007 to Sept. 2009 and meropenem within 1 year from Sept. 2008 in Beijing Tiantan Hospital, China. Data including the dosage and duration of the drug use, occurrence of seizures and mortality outcome was collected from the electronic pharmacy records. The incidence of epilepsy, epileptic standardized morbidity rate (SMR) were reported. Attention was paid to the relationship between the use of imipenem/meropenem and the incidence of epilepsy. The imipenem patients within two years amounted to 71, with mean age 45.9±20.2 years, male to female ratio 46/25. The incidence of epilepsy was 11.3% (8 cases). Among them, 1 case occurred during treatment (1/633, 1.6/1000 patient-days), and the remaining 7 cases occurred before treatment (7/2819, 2.5/1000 patient-days), with the standardized incidence rate 0.64, 95% CI (0.08-5.18).The meropenem patients within one year amounted to 92, mean age 45.1±19.4 years, male to female ratio 51/41. The incidence of epilepsy was 6.5% (6 cases). 2 occurred during treatment (2/582, 2.0/1000 patients-hospital days) and 4 before treatment (4/2047, 3.4/1000 patients-inpatient days), standardized incidence rate 1.76, 95% CI (0.32-9.63). Despite many other epileptogenic factors, imipenem or meropenem did not increase the risk of seizures in neurosurgical patients. There was not further risk for patients with pre-existing seizures or creatinine clearance abnormalities when dosed appropriate.

  15. Acinetobacter baumannii displays inverse relationship between meropenem resistance and biofilm production.

    Science.gov (United States)

    Perez, Leandro Reus Rodrigues

    2015-02-01

    In this study the ability for biofilm production among meropenem (MEM)-resistant and -susceptible Acinetobacter baumannii isolates was verified. MEM susceptibility and biofilm production were screened in 116 isolates. Meropenem-resistant A. baumannii isolates showed a reduced ability to produce biofilms compared to those susceptible to MEM (Pbaumanni isolates.

  16. Sustained Pulmonary Delivery of a Water-Soluble Antibiotic Without Encapsulating Carriers.

    Science.gov (United States)

    Ong, Winston; Nowak, Pawel; Cu, Yen; Schopf, Lisa; Bourassa, James; Enlow, Elizabeth; Moskowitz, Samuel M; Chen, Hongming

    2016-03-01

    Traditional polymeric nanoparticle formulations for prolonged local action during inhalation therapy are highly susceptible to muco-ciliary clearance. In addition, polymeric carriers are typically administered in high doses due to finite drug loading. For toxicological reasons, these carriers and their degradation byproducts are undesirable for inhalation therapy, particularly for chronic use, due to potential lung accumulation. We synthesized a novel, insoluble prodrug (MRPD) of a time-dependent β-lactam, meropenem, and formulated MRPD into mucus-penetrating crystals (MRPD-MPCs). After characterizing their mucus mobility (in vitro) and stability, we evaluated the lung pharmacokinetics of intratracheally-instilled MRPD-MPCs and a meropenem solution in guinea pigs. Meropenem levels rapidly declined in the lungs of guinea pigs receiving meropenem solution compared to those given MRPD-MPCs. At 9 h after dosing, drug levels in the lungs of animals that received meropenem solution dropped to 12 ng/mL, whereas those that received MRPD-MPCs maintained an average drug level of ≥1,065 ng/mL over a 12-h period. This work demonstrated that the combination of prodrug chemistry and mucus-penetrating platform created nanoparticles that produced sustained levels of meropenem in guinea pig lungs. This strategy represents a novel approach for sustained local drug delivery to the lung without using encapsulating matrices.

  17. Validation of HPLC and UV spectrophotometric methods for the determination of meropenem in pharmaceutical dosage form.

    Science.gov (United States)

    Mendez, Andreas S L; Steppe, Martin; Schapoval, Elfrides E S

    2003-12-04

    A high-performance liquid chromatographic method and a UV spectrophotometric method for the quantitative determination of meropenem, a highly active carbapenem antibiotic, in powder for injection were developed in present work. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by reversed-phase technique on an RP-18 column with a mobile phase composed of 30 mM monobasic phosphate buffer and acetonitrile (90:10; v/v), adjusted to pH 3.0 with orthophosphoric acid. The UV spectrophotometric method was performed at 298 nm. The samples were prepared in water and the stability of meropenem in aqueous solution at 4 and 25 degrees C was studied. The results were satisfactory with good stability after 24 h at 4 degrees C. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and can be used for the reliable quantitation of meropenem in pharmaceutical dosage form.

  18. Is High Dose Therapy Superior to Conventional Dose Therapy as Initial Treatment for Relapsed Germ Cell Tumors? The TIGER Trial

    Directory of Open Access Journals (Sweden)

    Darren R. Feldman, Robert Huddart, Emma Hall, Jörg Beyer, Thomas Powles

    2011-01-01

    Full Text Available Metastatic germ cell tumours (GCTs are usually cured with cisplatin based chemotherapy and standard treatment algorithms are established. However when this treatment fails and the disease relapses, standard treatment is much more uncertain. Both conventional dose therapy (CDT and high dose therapy (HDT are widely used, due to the lack of conclusive data supporting one specific approach. A recent retrospective analysis focusing on this population suggested a significant benefit for HDT. Retrospective analyses are prone to bias, and therefore while this data is provocative it is by no mean conclusive. For this reason the international community is supporting a prospective randomised trial in this area comparing CDT(TIP with sequential HDT (TICE. The planned open labelled randomised phase III study (TIGER is due to open in 2011 and will recruit 390 patients to detect a 13% difference in 2 year progression free survival (primary endpoint. It is hoped that this large study will conclusively resolve the uncertainty which currently exists.

  19. Therapeutic Efficacy of Meropenem for Treatment of Experimental Penicillin-Resistant Pneumococcal Meningitis

    Science.gov (United States)

    Kim, Shin-Woo; Jin, Joung Hwa; Kang, Soo Jung; Jung, Sook-In; Kim, Yeon-Sook; Kim, Choon-Kwan; Lee, Hyuck; Oh, Won Sup; Kim, Sungmin; Peck, Kyong Ran

    2004-01-01

    With the widespread emergence of antimicrobial resistance, combination regimens of ceftriaxone and vancomycin (C+V) or ceftriaxone and rifampin (C+R) are recommended for empirical treatment of pneumococcal meningitis. To evaluate the therapeutic efficacy of meropenem (M), we compared various treatment regimens in arabbit model of meningitis caused by penicillin-resistant Streptococcus pneumoniae (PRSP). Therapeutic efficacy was also evaluated by the final bacterial concentration in the cerebrospinal fluid (CSF) at 24 hr. Each group consisted of six rabbits. C+V cleared the CSF at 10 hr, but regrowth was noted in 3 rabbits at 24 hr. Meropenem monotherapy resulted in sterilization at 10 hr, but regrowth was observed in all 6 rabbits at 24 hr. M+V also resulted in sterilization at 10 hr, but regrowth was observed in 2 rabbits at 24 hr. M+V was superior to the meropenem monotherapy at 24 hr (reduction of 4.8 vs. 1.8 log10 cfu/mL, respectively; p=0.003). The therapeutic efficacy of M+V was comparable to that of C+V (reduction of 4.8 vs. 4.0 log10 cfu/mL, respectively; p=0.054). The meropenem monotherapy may not be a suitable choice for PRSP meningitis, while combination of meropenem and vancomycin could be a possible alternative in the treatment of PRSP meningitis. PMID:14966336

  20. Comparison of fixed low dose versus high dose radioactive iodine for the treatment of hyperthyroidism: retrospective multifactorial analysis impacting the outcome of therapy

    International Nuclear Information System (INIS)

    Suresh Kumar, A.C.; Malhotra, G.; Basu, S.; Asopa, R.V.

    2010-01-01

    Full text: Radioactive iodine ( 131 I) as a fixed dose protocol is widely used for treatment of hyperthyroidism. However, there is no consensus on the best optimum dose for an individual patient. The objectives of this study were to observe the outcome of 131 I therapy in patients of primary hyperthyroidism in relation to fixed low dose versus high dose regimen, impact of antithyroid drugs and influence of thyroid gland size on therapy outcome. Materials and Methods: Study design: Retrospective analysis. Study group included 287 diagnosed patients of primary hyperthyroidism who had undergone 131 I therapy for the first time (68 M, 219 F; Mean age ± S.D.: 43.84 ± 12.53). All patients with low RAIU, thyrocardiac disease were excluded. Details of antithyroid (ATD) drug treatment were recorded. Analysis was done from 2002 till patients became euthyroid/hypothyroid or until January 2010. Each patient's response was evaluated initially at 6 weeks and thereafter every three months. Appropriate statistical tests were applied to compare treatment response between the groups. A P value<0.05 was considered significant. Results: Of 287 patients, 209 patients had been administered low dose (Mean ± S.D.: 4.68 ± 0.62 mCi) while 78 patients had received high dose (Mean ± S.D.: 9.15 ± 1.05 mCi) of radioiodine. 57.9% (121/ 209) patients in the low dose group responded as compared to 75.6% (59/78) in high dose group after a follow up of more than 36 months. Similarly, among patients with and without antithyroid drug treatment, grade II and above goiters the response rates were significantly higher for high dose group as compared to low dose group. Conclusion: We suggest that high dose radioiodine treatment with 8 to 10 mCi is effective in treating hyperthyroidism in patients with a better success rate than the low dose treatment with 3 to 5 mCi. This is also likely to be helpful in patients who have not received antithyroid drugs. It appears that clinically relevant

  1. Optimal dose-response relationships in voice therapy.

    Science.gov (United States)

    Roy, Nelson

    2012-10-01

    Like other areas of speech-language pathology, the behavioural management of voice disorders lacks precision regarding optimal dose-response relationships. In voice therapy, dosing can presumably vary from no measurable effect (i.e., no observable benefit or adverse effect), to ideal dose (maximum benefit with no adverse effects), to doses that produce toxic or harmful effects on voice production. Practicing specific vocal exercises will inevitably increase vocal load. At ideal doses, these exercises may be non-toxic and beneficial, while at intermediate or high doses, the same exercises may actually be toxic or damaging to vocal fold tissues. In pharmacology, toxicity is a critical concept, yet it is rarely considered in voice therapy, with little known regarding "effective" concentrations of specific voice therapies vs "toxic" concentrations. The potential for vocal fold tissue damage related to overdosing on specific vocal exercises has been under-studied. In this commentary, the issue of dosing will be explored within the context of voice therapy, with particular emphasis placed on possible "overdosing".

  2. Meropenem-Clavulanate is Effective Against Extensive Drug-Resistant Mycobacterium Tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Hugonnet, J.; Tremblay, L; Boshoff, H; Barry, C; Blanchard, J

    2009-01-01

    e-lactam antibiotics are ineffective against Mycobacterium tuberculosis, being rapidly hydrolyzed by the chromosomally encoded blaC gene product. The carbapenem class of e-lactams are very poor substrates for BlaC, allowing us to determine the three-dimensional structure of the covalent BlaC-meropenem covalent complex at 1.8 angstrom resolution. When meropenem was combined with the e-lactamase inhibitor clavulanate, potent activity against laboratory strains of M. tuberculosis was observed [minimum inhibitory concentration (MICmeropenem) less than 1 microgram per milliliter], and sterilization of aerobically grown cultures was observed within 14 days. In addition, this combination exhibited inhibitory activity against anaerobically grown cultures that mimic the 'persistent' state and inhibited the growth of 13 extensively drug-resistant strains of M. tuberculosis at the same levels seen for drug-susceptible strains. Meropenem and clavulanate are Food and Drug Administration-approved drugs and could potentially be used to treat patients with currently untreatable disease.

  3. Pharmacodynamic profiling of doripenem, imipenem and meropenem against prevalent Gram-negative organisms in the Asia-Pacific region.

    Science.gov (United States)

    Kiratisin, Pattarachai; Keel, Rebecca A; Nicolau, David P

    2013-01-01

    Carbapenems are increasingly being utilised owing to the escalating prevalence of antimicrobial-resistant Gram-negative bacteria from community and hospital settings. In this study, pharmacodynamic profiles of doripenem, imipenem and meropenem were evaluated against Gram-negative bacteria isolated from hospitalised patients. MICs for carbapenems were determined for Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter baumannii obtained from the COMPACT II programme conducted in the Asia-Pacific region. Monte Carlo simulations were undertaken to assess the pharmacodynamic profile of carbapenems against each of the pathogens. All carbapenem regimens achieved optimal exposures [cumulative fraction of response (CFR) ≥90%] against E. coli and K. pneumoniae. Against P. aeruginosa, doripenem achieved 81.3-95.3% CFR, imipenem achieved 55.2-77.9% CFR and meropenem achieved 71.9-91.3% CFR; only doripenem regimens of 4-h infusion of 1000 mg every 8h (q8h) and 1-h and 4-h infusion of 2000 mg q8h and a meropenem regimen of 3-h infusion of 2000 mg q8h obtained optimal exposures; all carbapenem regimens showed slight (1-7%) improvement in CFRs in favour of isolates collected from ICU sources. Against A. baumannii, CFRs were much lower (25.9-46.7% CFR) and no carbapenem regimens achieved optimal exposure in or outside the ICU. Owing to the high potency of carbapenems against these Enterobacteriaceae populations, standard regimens are likely to perform well in the Asia-Pacific region. However, larger doses combined with prolonged infusions will be required to increase the CFR for these carbapenems against resistant non-fermenting Gram-negatives such as P. aeruginosa and A. baumannii that are prevalent in these countries. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  4. High-dose ibuprofen therapy associated with esophageal ulceration after pneumonectomy in a patient with cystic fibrosis: a case report

    Directory of Open Access Journals (Sweden)

    Anbar Ran D

    2004-09-01

    Full Text Available Abstract Background Lung disease in patients with cystic fibrosis is thought to develop as a result of airway inflammation, infection, and obstruction. Pulmonary therapies for cystic fibrosis that reduce airway inflammation include corticosteroids, rhDNase, antibiotics, and high-dose ibuprofen. Despite evidence that high-dose ibuprofen slows the progression of lung disease in patients with cystic fibrosis, many clinicians have chosen not to use this therapy because of concerns regarding potential side effects, especially gastrointestinal bleeding. However, studies have shown a low incidence of gastrointestinal ulceration and bleeding in patients with cystic fibrosis who have been treated with high-dose ibuprofen. Case presentation The described case illustrates a life-threatening upper gastrointestinal bleed that may have resulted from high-dose ibuprofen therapy in a patient with CF who had undergone a pneumonectomy. Mediastinal shift post-pneumonectomy distorted the patient's esophageal anatomy and may have caused decreased esophageal motility, which led to prolonged contact of the ibuprofen with the esophagus. The concentrated effect of the ibuprofen, as well as its systemic effects, probably contributed to the occurrence of the bleed in this patient. Conclusions This report demonstrates that gastrointestinal tract anatomical abnormalities or dysmotility may be contraindications for therapy with high-dose ibuprofen in patients with cystic fibrosis.

  5. The Effect of High Dose Radioiodine Therapy on Formation of Radiation Retinopathy During Thyroid Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Tülay Kaçar Güvel

    2014-10-01

    Full Text Available Objective: Non-thyroidal complication of high-dose radioiodine therapy for thyroid carcinoma might cause salivary and lacrimal gland dysfunction, which may be transient or permanent in a dose-dependent manner. However, radiation retinopathy complicating 131I therapy, has not been previously well characterized. The aim of this study was to evaluate the extent of retinal damage among patients who had received high doses of radioiodine treatment. Methods: Forty eyes of 20 patients (3 male, 17 female who received 250-1000 mCi during 131I therapy and on ophthalmological follow up for a year after the last treatment were included in the study. Mean age of the study group was 50 years (range 25-70 years. In ophthalmologic examination, visual acuity was measured in order to determine visual loss. Intraocular pressure was measured in all the patients. Then lens examination was carried out with slit lamp biomicroscopy in order to investigate cataract or partial lens opacities. Fundus observation was carried out through the dilated pupil with slit lamp biomicroscopy using 90 D noncontact lens. Result: The best corrected visual aquity with Snellen chart was found as 1.0 in 36 eyes (90% and between 0.6 and 0.9 (10% in 4 eyes (10%. At the biomicroscopic fundus examination, retinal hemorrhage consistent with radiation retinopathy, microaneurysm, microinfarction, edema or exudation, vitreus hemorrhage, partial or total optical disc pallor indicating papillopathy in the optic disc were not observed in any of the eyes. Conclusion: This result indicates that there is not any significant correlation between repeated high-dose radioiodine therapy and radiation retinopathy in differentiated thyroid carcinomas. Even though there is not a significant restriction in use of higher doses of radioiodine therapy in differentiated thyroid carcinoma, more extensive studies are needed in order to obtain more accurate data on possible occurrence of retinopathy.

  6. Long-term results of exclusive low-dose rate curie-therapy for a high-grade vaginal intraepithelial neoplasia

    International Nuclear Information System (INIS)

    Blanchard, P.; Monnier, L.; Dumas, I.; Azoury, F.; Mazeron, R.; Haie-Meder, C.

    2010-01-01

    The authors report the results of an exclusive low dose rate curie therapy for female patients treated for a grade 3 vaginal intraepithelial neoplasia. They reviewed the medical files of patients treated since 1983, i.e. 28 women. They analysed demographic characteristics, the clinic description of lesions, possible treatments which occurred before this high-grade vaginal intraepithelial neoplasia, possible previous history of cervical or endometrial cancer, curie therapy detailed data, presence of tumorous relapse. According to that, they conclude that a 60 Gy exclusive low- vaginal dose-rate curie-therapy is an efficient and well tolerated treatment for high-grade vaginal intraepithelial neoplasia. Short communication

  7. High-dose proton beam therapy for sinonasal mucosal malignant melanoma

    International Nuclear Information System (INIS)

    Fuji, Hiroshi; Yoshikawa, Shusuke; Kasami, Masako; Murayama, Shigeyuki; Onitsuka, Tetsuro; Kashiwagi, Hiroya; Kiyohara, Yoshio

    2014-01-01

    The significance of definitive radiotherapy for sinonasal mucosal melanoma (SMM) is sill controvertial. This study was to evaluate the role of high-dose proton beam therapy (PBT) in patients with SMM. The cases of 20 patients with SMM localized to the primary site who were treated by PBT between 2006 and 2012 were retrospectively analyzed. The patterns of overall survival and morbidity were assessed. The median follow-up time was 35 months (range, 6–77 months). The 5-year overall and disease-free survival rates were 51% and 38%, respectively. Four patients showed local failure, 2 showed regrowth of the primary tumor, and 2 showed new sinonasal tumors beyond the primary site. The 5-year local control rate after PBT was 62%. Nodal and distant failure was seen in 7 patients. Three grade 4 late toxicities were observed in tumor-involved optic nerve. Our findings suggested that high-dose PBT is an effective local treatment that is less invasive than surgery but with comparable outcomes

  8. Chemometrically assisted development and validation of LC-MS/MS method for the analysis of potential genotoxic impurities in meropenem active pharmaceutical ingredient.

    Science.gov (United States)

    Grigori, Katerina; Loukas, Yannis L; Malenović, Anđelija; Samara, Vicky; Kalaskani, Anastasia; Dimovasili, Efi; Kalovidouri, Magda; Dotsikas, Yannis

    2017-10-25

    A sensitive Liquid Chromatography tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of three potential genotoxic impurities (318BP, M9, S5) in meropenem Active Pharmaceutical Ingredient (API). Due to the requirement for LOD values in ppb range, a high concentration of meropenem API (30mg/mL) had to be injected. Therefore, efficient determination of meropenem from its impurities became a critical aim of this study, in order to divert meropenem to waste, via a switching valve. ‎ After the selection of the important factors affecting analytes' elution, a Box-Behnken design was utilized to set the plan of experiments conducted with UV detector. As responses, the separation factor s between the last eluting impurity and meropenem, as well as meropenem retention factor k were used. Grid point search methodology was implemented aiming to obtain the optimal conditions that simultaneously comply to the conflicted criteria. Optimal mobile phase consisted of ACN, methanol and 0.09% HCOOH at a ratio 71/3.5/15.5v/v. All impurities and internal standard omeprazole were eluted before 7.5min and at 8.0min the eluents were directed to waste. The protocol was transferred to LC-MS/MS and validated according to ICH guidelines. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. High-dose therapy followed by bone marrow transplantation for relapsed follicular non-Hodgkin's lymphoma

    NARCIS (Netherlands)

    Schouten, IC; Raemaekers, JJM; Kluin-Nelemans, HC; vanKamp, H; Mellink, WAM; vantVeer, MB

    1996-01-01

    Purpose: To analyze whether, in addition to survival, and disease-free survival progression-free interval after transplantation would be longer than the last progression-free interval before transplantation, supporting the argument that high-dose therapy may change the biologic behavior of the

  10. Meropenem in cystic fibrosis patients infected with resistant Pseudomonas aeruginosa or Burkholderia cepacia and with hypersensitivity to beta-lactam antibiotics

    DEFF Research Database (Denmark)

    Ciofu, Oana; Jensen, Tim; Pressler, Tacjana

    1996-01-01

    in pulmonary function (as a percentage of the predictive values) was 5.6% for FEV1 (forced expiratory volume in the first second) and 8.6% for FVC (forced vital capacity). C-reactive protein and erythrocyte sedimentation rate (ESR) and leukocyte count decreased significantly. In courses administered...... for chronic infection with B. cepacia the post treatment FEV1 and FVC values were higher than the pre-treatment values, and all the inflammatory parameters decreased. The geometric means of minimal inhibitory concentration (MICs) (microg/mL) for P. aeruginosa (B. cepacia) were: tobramycin 6 (59......), ciprofloxacin 1.2 (9.7), piperacillin 49 (16.3), ceftazidime 26 (23), aztreonam 26 (35), imipenem 6.4 (not determined) and meropenem 5.1 (4.8). No statistically significant increase in the MICs of meropenem for either pathogen occurred during therapy. Of the 124 courses, 115 were tolerated without any clinical...

  11. Microfluidic thrombosis under multiple shear rates and antiplatelet therapy doses.

    Directory of Open Access Journals (Sweden)

    Melissa Li

    Full Text Available The mainstay of treatment for thrombosis, the formation of occlusive platelet aggregates that often lead to heart attack and stroke, is antiplatelet therapy. Antiplatelet therapy dosing and resistance are poorly understood, leading to potential incorrect and ineffective dosing. Shear rate is also suspected to play a major role in thrombosis, but instrumentation to measure its influence has been limited by flow conditions, agonist use, and non-systematic and/or non-quantitative studies. In this work we measured occlusion times and thrombus detachment for a range of initial shear rates (500, 1500, 4000, and 10000 s(-1 and therapy concentrations (0-2.4 µM for eptifibatide, 0-2 mM for acetyl-salicylic acid (ASA, 3.5-40 Units/L for heparin using a microfluidic device. We also measured complete blood counts (CBC and platelet activity using whole blood impedance aggregometry. Effects of shear rate and dose were analyzed using general linear models, logistic regressions, and Cox proportional hazards models. Shear rates have significant effects on thrombosis/dose-response curves for all tested therapies. ASA has little effect on high shear occlusion times, even at very high doses (up to 20 times the recommended dose. Under ASA therapy, thrombi formed at high shear rates were 4 times more prone to detachment compared to those formed under control conditions. Eptifibatide reduced occlusion when controlling for shear rate and its efficacy increased with dose concentration. In contrast, the hazard of occlusion from ASA was several orders of magnitude higher than that of eptifibatide. Our results show similar dose efficacy to our low shear measurements using whole blood aggregometry. This quantitative and statistically validated study of the effects of a wide range of shear rate and antiplatelet therapy doses on occlusive thrombosis contributes to more accurate understanding of thrombosis and to models for optimizing patient treatment.

  12. Lipid Rescue Therapy and High-Dose insulin Euglycemic Therapy are Effective for Severe Refractory Calcium Channel Blocker Overdose: Case Report and Review of Literature

    Directory of Open Access Journals (Sweden)

    Niko Bekjarovski

    2013-09-01

    How to cite this article: Bekjarovski NG. Lipid Rescue Therapy and High-Dose insulin Euglycemic Therapy are Effective for Severe Refractory Calcium Channel Blocker Overdose: Case Report and Review of Literature. Asia Pac J Med Toxicol 2013;2:114-6.

  13. Time-dose relationship of erythema in high energy photon irradiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hidetoshi (Gifu Prefectural Tajimi Hospital (Japan)); Sakuma, Sadayuki

    1992-01-01

    Skin doses of 100 patients who were treated with high energy ionizing irradiation during conventional irradiation therapy were measured by thermoluminescence dosimeter (TLD). In 87 of the 100 patients, acute hyperemic change of the skin (erythema) of the irradiated region was observed. In the other 13 patients, alopetia of the scalp was observed. The following conclusions were reached. The time-dose relationship was linear when erythema tolerance was used as an index, but not when alopecia was used. The tolerance dose for erythema was lower than previously reported. The slope of the isoeffect curve on the log-log plot of total absorbed skin dose against total number of days after the first irradiation was 0.68 when erythema was used as an index. This number is larger than previously reported results. We considered that erythema is significantly influenced by fraction size and that hyperfractionation is a promising method of irradiation, especially in Japan. Combined use of chemotherapeutic agents, such as 5-FU, accelerated erythema. The slope of combined treatment was 0.86. Observing acute hyperemic change of skin is considered to be a useful method of investigating the combined effects of chemotherapeutic agents on irradiation. (author).

  14. High-dose superselective intra-arterial cisplatin and concomitant radiation therapy for carcinoma of the oral cavity

    International Nuclear Information System (INIS)

    Suzuki, Gen; Tanaka, Norimitsu; Ogo, Etuyo

    2007-01-01

    The purpose of this study was to evaluate the effect of high-dose superselective intra-arterial cisplatin and concomitant radiation therapy for carcinoma of the oral cavities. The subjects consisted of 18 patients with carcinoma of the oral, and cavity treated with superselective intra-arterial infusion of high dose cisplatin (100 mg/body) concomitant with delivery of external beam radiotherapy (median total dose, 60.8 Gy) between 2001 and 2004. Sodium thiosulfate was administered intravenously to provide effective cisplatin neutlization. They were International Union Against Cancer (UICC)1997 stage II-IV (stage II: 4 patients, stage III: 4 patients, stage IV: 10 patients). Patients ranged from 43-81 years of age, with a median of 60 years, and included 14 men and 4 women. A follow-up period was 6 months minimum from the atart of the radiation therapy, the median follow up period at 28 months. The three-year overall survival rate was 71%. The three-year disease free rate and local control rate were 60% and 65%, respectively. Three-year local control rate of the T2-3 was achieved at 83%, and that for T4 at 50%. There was borderline significant difference in local control rate between T2-3 and T4 (p=0.05). We conclude that the high-dose superselective intra-arterial cisplatin and concomitant radiation therapy provides effective results in organ preservation for cancer of oral cavities. Further studies are also required to determine the validity of this method. (author)

  15. Dosimetric Considerations to Determine the Optimal Technique for Localized Prostate Cancer Among External Photon, Proton, or Carbon-Ion Therapy and High-Dose-Rate or Low-Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Georg, Dietmar, E-mail: Dietmar.Georg@akhwien.at [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Hopfgartner, Johannes [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Gòra, Joanna [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Kuess, Peter [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Kragl, Gabriele [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Berger, Daniel [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Hegazy, Neamat [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Goldner, Gregor; Georg, Petra [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria)

    2014-03-01

    Purpose: To assess the dosimetric differences among volumetric modulated arc therapy (VMAT), scanned proton therapy (intensity-modulated proton therapy, IMPT), scanned carbon-ion therapy (intensity-modulated carbon-ion therapy, IMIT), and low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy (BT) treatment of localized prostate cancer. Methods and Materials: Ten patients were considered for this planning study. For external beam radiation therapy (EBRT), planning target volume was created by adding a margin of 5 mm (lateral/anterior–posterior) and 8 mm (superior–inferior) to the clinical target volume. Bladder wall (BW), rectal wall (RW), femoral heads, urethra, and pelvic tissue were considered as organs at risk. For VMAT and IMPT, 78 Gy(relative biological effectiveness, RBE)/2 Gy were prescribed. The IMIT was based on 66 Gy(RBE)/20 fractions. The clinical target volume planning aims for HDR-BT ({sup 192}Ir) and LDR-BT ({sup 125}I) were D{sub 90%} ≥34 Gy in 8.5 Gy per fraction and D{sub 90%} ≥145 Gy. Both physical and RBE-weighted dose distributions for protons and carbon-ions were converted to dose distributions based on 2-Gy(IsoE) fractions. From these dose distributions various dose and dose–volume parameters were extracted. Results: Rectal wall exposure 30-70 Gy(IsoE) was reduced for IMIT, LDR-BT, and HDR-BT when compared with VMAT and IMPT. The high-dose region of the BW dose–volume histogram above 50 Gy(IsoE) of IMPT resembled the VMAT shape, whereas all other techniques showed a significantly lower high-dose region. For all 3 EBRT techniques similar urethra D{sub mean} around 74 Gy(IsoE) were obtained. The LDR-BT results were approximately 30 Gy(IsoE) higher, HDR-BT 10 Gy(IsoE) lower. Normal tissue and femoral head sparing was best with BT. Conclusion: Despite the different EBRT prescription and fractionation schemes, the high-dose regions of BW and RW expressed in Gy(IsoE) were on the same order of magnitude. Brachytherapy techniques

  16. Dosimetric Considerations to Determine the Optimal Technique for Localized Prostate Cancer Among External Photon, Proton, or Carbon-Ion Therapy and High-Dose-Rate or Low-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Georg, Dietmar; Hopfgartner, Johannes; Gòra, Joanna; Kuess, Peter; Kragl, Gabriele; Berger, Daniel; Hegazy, Neamat; Goldner, Gregor; Georg, Petra

    2014-01-01

    Purpose: To assess the dosimetric differences among volumetric modulated arc therapy (VMAT), scanned proton therapy (intensity-modulated proton therapy, IMPT), scanned carbon-ion therapy (intensity-modulated carbon-ion therapy, IMIT), and low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy (BT) treatment of localized prostate cancer. Methods and Materials: Ten patients were considered for this planning study. For external beam radiation therapy (EBRT), planning target volume was created by adding a margin of 5 mm (lateral/anterior–posterior) and 8 mm (superior–inferior) to the clinical target volume. Bladder wall (BW), rectal wall (RW), femoral heads, urethra, and pelvic tissue were considered as organs at risk. For VMAT and IMPT, 78 Gy(relative biological effectiveness, RBE)/2 Gy were prescribed. The IMIT was based on 66 Gy(RBE)/20 fractions. The clinical target volume planning aims for HDR-BT ( 192 Ir) and LDR-BT ( 125 I) were D 90% ≥34 Gy in 8.5 Gy per fraction and D 90% ≥145 Gy. Both physical and RBE-weighted dose distributions for protons and carbon-ions were converted to dose distributions based on 2-Gy(IsoE) fractions. From these dose distributions various dose and dose–volume parameters were extracted. Results: Rectal wall exposure 30-70 Gy(IsoE) was reduced for IMIT, LDR-BT, and HDR-BT when compared with VMAT and IMPT. The high-dose region of the BW dose–volume histogram above 50 Gy(IsoE) of IMPT resembled the VMAT shape, whereas all other techniques showed a significantly lower high-dose region. For all 3 EBRT techniques similar urethra D mean around 74 Gy(IsoE) were obtained. The LDR-BT results were approximately 30 Gy(IsoE) higher, HDR-BT 10 Gy(IsoE) lower. Normal tissue and femoral head sparing was best with BT. Conclusion: Despite the different EBRT prescription and fractionation schemes, the high-dose regions of BW and RW expressed in Gy(IsoE) were on the same order of magnitude. Brachytherapy techniques were clearly superior in

  17. Occurrence of chronic esophageal ulcer after high dose rate intraluminal radiation therapy for esophageal cancer

    International Nuclear Information System (INIS)

    Soejima, Toshinori; Hirota, Saeko; Okamoto, Yoshiaki; Obayashi, Kayoko; Takada, Yoshiki

    1995-01-01

    Ninety-eight patients with esophageal cancer were treated by high dose rate intraluminal radiation therapy at the Department of Radiology of the Hyogo Medical Center for Adults between January 1982 and December 1993. Twenty patients with complete response after intraluminal radiation therapy, who were followed up with esophageal fiberscopy in our institute, were reviewed. The one-year cumulative rate of occurrence of esophageal ulcers was 81%, and in 69% of the cases the ulcers occurred from 4 to 8 months after completion of intraluminal radiation therapy. We graded esophageal ulcer by fiberscopic findings. Grade 0 was defined as no ulcer, grade 1 as superficial ulcer, grade 2 as deep ulcer, grade 3 as circumferencial ulcer, and severe stenosis. Factors related to grade were studied, and shorter distances from the source to the surface of the mucosa and lower surface doses of intraluminal radiation therapy appear to reduce the severity as graded on the above scale, of the esophageal ulcer. Four of the five 2-year recurrence-free patients suffered esophageal ulcers, which were cured from 15 to 22 months after intraluminal radiation therapy. However ulcers recurred in two patients, ong term care was thought to be necessary. (author)

  18. A prospective, observational study comparing the PK/PD relationships of generic Meropenem (Mercide®) to the innovator brand in critically ill patients.

    Science.gov (United States)

    Mer, Mervyn; Snyman, Jacques Rene; van Rensburg, Constance Elizabeth Jansen; van Tonder, Jacob John; Laurens, Ilze

    2016-01-01

    Clinicians' skepticism, fueled by evidence of inferiority of some multisource generic antimicrobial products, results in the underutilization of more cost-effective generics, especially in critically ill patients. The aim of this observational study was to demonstrate equivalence between the generic or comparator brand of meropenem (Mercide ® ) and the leading innovator brand (Meronem ® ) by means of an ex vivo technique whereby antimicrobial activity is used to estimate plasma concentration of the active moiety. Patients from different high care and intensive care units were recruited for observation when prescribed either of the meropenem brands under investigation. Blood samples were collected over 6 hours after a 30 minute infusion of the different brands. Meropenem concentration curves were established against United States Pharmacopeia standard meropenem (Sigma-Aldrich) by using standard laboratory techniques for culture of Klebsiella pneumoniae. Patients' plasma samples were tested ex vivo, using a disc diffusion assay, to confirm antimicrobial activity and estimate plasma concentrations of the two brands. Both brands of meropenem demonstrated similar curves in donor plasma when concentrations in vials were confirmed. Patient-specific serum concentrations were determined from zones of inhibition against a standard laboratory Klebsiella strain ex vivo, confirming at least similar in vivo concentrations as the concentration curves (90% confidence interval) overlapped; however, the upper limit of the area under the curve for the ratio comparator/innovator exceeded the 1.25-point estimate, i.e., 4% higher for comparator meropenem. This observational, in-practice study demonstrates similar ex vivo activity and in vivo plasma concentration time curves for the products under observation. Assay sensitivity is also confirmed. Current registration status of generic small molecules is in place. The products are therefore clinically interchangeable based on

  19. Low- and high-dose radioiodine therapy for low-/intermediate-risk differentiated thyroid cancer. A preliminary clinical trial

    International Nuclear Information System (INIS)

    Qu Yuan; Huang Rui; Li Lin

    2017-01-01

    To compare the ablation results, therapeutic responses and adverse reactions between a low dose (1.1 GBq) or high dose (3.7 GBq) of 131 I in low-/intermediate-risk differentiated thyroid cancer (DTC) patients. The factors influencing the ablation result and therapeutic response were also analyzed. The researchers used a random number table to randomly assign the enrolled patients to the low-dose group or high-dose group at a 1:1 ratio, and assessment of ablation result, therapeutic response, and adverse reactions evaluated 6 ± 3 months after therapy. A total of 140 patients were enrolled in the study through October 2014-June 2015. Until February 2016, 132 patients completed the trial. 99 patients were re-examined under thyroid-stimulating hormone (TSH) stimulation 3-9 months after 131 I therapy. For the low-dose and high-dose groups, the success rates of ablation were 52.7% (29/55) and 59.1% (26/44), respectively. The ablation results did not differ significantly between the two groups (P = 0.548). One hundred and thirty two patients were re-examined 2-9 months after 131 I therapy. The low-dose group had an excellent response rate of ∼80% (53/66), an indeterminate response rate of ∼ 20% (13/66), and no cases with a biochemical incomplete response. The high-dose group had an excellent response rate of ∼85% (36/66), an indeterminate response rate of ∼11% (7/66), and a biochemical incomplete response rate of ∼4% (3/66). No significant differences in the therapeutic response were observed between the two groups (P = 0.087). Patients in stage N1b had a significantly lower success rate of ablation than those in stage N0 (P = 0.000). The success rate of ablation increased significantly with lower thyroglobulin (Tg) levels (P = 0.000). A pre-treatment Tg level was significantly associated with a higher excellent response rate (P = 0.002). Pre-treatment-stimulated Tg of 0.47 and 3.09 μg/L were identified as cut-off values for predicting the ablation result and

  20. Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi

    2016-11-08

    Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.

  1. High biologically effective dose radiation therapy using brachytherapy in combination with external beam radiotherapy for high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Keisei Okamoto

    2017-02-01

    Full Text Available Purpose : To evaluate the outcomes of high-risk prostate cancer patients treated with biologically effective dose (BED ≥ 220 Gy of high-dose radiotherapy, using low-dose-rate (LDR brachytherapy in combination with external beam radiotherapy (EBRT and short-term androgen deprivation therapy (ADT. Material and methods : From 2005 to 2013, a total of 143 patients with high-risk prostate cancer were treated by radiotherapy of BED ≥ 220 Gy with a combination of LDR brachytherapy, EBRT, and androgen deprivation therapy (ADT. The high-risk patients in the present study included both high-risk and very high-risk prostate cancer. The number of high-risk features were: 60 patients with 1 high-risk factor (42%, 61 patients with 2 high-risk factors (43%, and 22 patients with 3 high-risk factors (15% including five N1 disease. External beam radiotherapy fields included prostate and seminal vesicles only or whole pelvis depending on the extension of the disease. Biochemical failure was defined by the Phoenix definition. Results : Six patients developed biochemical failure, thus providing a 5-year actual biochemical failure-free survival (BFFS rate of 95.2%. Biochemical failure was observed exclusively in cases with distant metastasis in the present study. All six patients with biochemical relapse had clinical failure due to bone metastasis, thus yielding a 5-year freedom from clinical failure (FFCF rate of 93.0%. None of the cases with N1 disease experienced biochemical failure. We observed four deaths, including one death from prostate cancer, therefore yielding a cause-specific survival (CSS rate of 97.2%, and an overall survival (OS rate of 95.5%. Conclusions : High-dose (BED ≥ 220 Gy radiotherapy by LDR in combination with EBRT has shown an excellent outcome on BFFS in high-risk and very high-risk cancer, although causal relationship between BED and BFFS remain to be explained further.

  2. Dose distribution following selective internal radiation therapy

    International Nuclear Information System (INIS)

    Fox, R.A.; Klemp, P.F.; Egan, G.; Mina, L.L.; Burton, M.A.; Gray, B.N.

    1991-01-01

    Selective Internal Radiation Therapy is the intrahepatic arterial injection of microspheres labelled with 90Y. The microspheres lodge in the precapillary circulation of tumor resulting in internal radiation therapy. The activity of the 90Y injected is managed by successive administrations of labelled microspheres and after each injection probing the liver with a calibrated beta probe to assess the dose to the superficial layers of normal tissue. Predicted doses of 75 Gy have been delivered without subsequent evidence of radiation damage to normal cells. This contrasts with the complications resulting from doses in excess of 30 Gy delivered from external beam radiotherapy. Detailed analysis of microsphere distribution in a cubic centimeter of normal liver and the calculation of dose to a 3-dimensional fine grid has shown that the radiation distribution created by the finite size and distribution of the microspheres results in an highly heterogeneous dose pattern. It has been shown that a third of normal liver will receive less than 33.7% of the dose predicted by assuming an homogeneous distribution of 90Y

  3. Dose specification for radiation therapy: dose to water or dose to medium?

    International Nuclear Information System (INIS)

    Ma, C-M; Li Jinsheng

    2011-01-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  4. Plasma and CSF pharmacokinetics of meropenem in neonates and young infants: results from the NeoMero studies.

    Science.gov (United States)

    Germovsek, Eva; Lutsar, Irja; Kipper, Karin; Karlsson, Mats O; Planche, Tim; Chazallon, Corine; Meyer, Laurence; Trafojer, Ursula M T; Metsvaht, Tuuli; Fournier, Isabelle; Sharland, Mike; Heath, Paul; Standing, Joseph F

    2018-04-19

    Sepsis and bacterial meningitis are major causes of mortality and morbidity in neonates and infants. Meropenem, a broad-spectrum antibiotic, is not licensed for use in neonates and infants below 3 months of age and sufficient information on its plasma and CSF disposition and dosing in neonates and infants is lacking. To determine plasma and CSF pharmacokinetics of meropenem in neonates and young infants and the link between pharmacokinetics and clinical outcomes in babies with late-onset sepsis (LOS). Data were collected in two recently conducted studies, i.e. NeoMero-1 (neonatal LOS) and NeoMero-2 (neonatal meningitis). Optimally timed plasma samples (n = 401) from 167 patients and opportunistic CSF samples (n = 78) from 56 patients were analysed. A one-compartment model with allometric scaling and fixed maturation gave adequate fit to both plasma and CSF data; the CL and volume (standardized to 70 kg) were 16.7 (95% CI 14.7, 18.9) L/h and 38.6 (95% CI 34.9, 43.4) L, respectively. CSF penetration was low (8%), but rose with increasing CSF protein, with 40% penetration predicted at a protein concentration of 6 g/L. Increased infusion time improved plasma target attainment, but lowered CSF concentrations. For 24 patients with culture-proven Gram-negative LOS, pharmacodynamic target attainment was similar regardless of the test-of-cure visit outcome. Simulations showed that longer infusions increase plasma PTA but decrease CSF PTA. CSF penetration is worsened with long infusions so increasing dose frequency to achieve therapeutic targets should be considered.

  5. Activity of Simulated Human Dosage Regimens of Meropenem and Vaborbactam against Carbapenem-Resistant Enterobacteriaceae in an In Vitro Hollow-Fiber Model.

    Science.gov (United States)

    Sabet, Mojgan; Tarazi, Ziad; Rubio-Aparicio, Debora; Nolan, Thomas G; Parkinson, Jonathan; Lomovskaya, Olga; Dudley, Michael N; Griffith, David C

    2018-02-01

    The objective of these studies was to evaluate the exposures of meropenem and vaborbactam that would produce antibacterial activity and prevent resistance development in carbapenem-resistant Klebsiella pneumoniae carbapenemase (KPC)-producing Enterobacteriaceae strains when tested at an inoculum of 10 8 CFU/ml. Thirteen K. pneumoniae isolates, three Enterobacter cloacae isolates, and one Escherichia coli isolate were examined in an in vitro hollow-fiber model over 32 h. Simulated dosage regimens of 1 to 2 g of meropenem with 1 to 2 g of vaborbactam, with meropenem administered every 8 h by a 3-h infusion based on phase 1 or phase 3 patient pharmacokinetic data, were studied in the model. A dosage of 2 g of meropenem in combination with 2 g of vaborbactam was bactericidal against K. pneumoniae , E. cloacae , and E. coli strains, with meropenem-vaborbactam MICs of up to 8 mg/liter. When the vaborbactam exposure was adjusted to the levels observed in patients enrolled in phase 3 trials (24-h free AUC, ∼550 mg · h/liter, versus 320 mg · h/liter in the phase 1 studies), 2 g of meropenem with 2 g of vaborbactam was also bactericidal against strains with meropenem-vaborbactam MICs of 16 mg/liter. In addition, this level of vaborbactam also suppressed the development of resistance observed using phase 1 exposures. In this pharmacodynamic model, exposures similar to 2 g of meropenem in combination with 2 g of vaborbactam administered every 8 h by a 3-h infusion in phase 3 trials produced antibacterial activity and suppressed the development of resistance against carbapenem-resistant KPC-producing strains of Enterobacteriaceae . Copyright © 2018 American Society for Microbiology.

  6. A prospective, observational study comparing the PK/PD relationships of generic Meropenem (Mercide® to the innovator brand in critically ill patients

    Directory of Open Access Journals (Sweden)

    Mer M

    2016-11-01

    Full Text Available Mervyn Mer,1 Jacques Rene Snyman,2 Constance Elizabeth Jansen van Rensburg,2 Jacob John van Tonder,3 Ilze Laurens2 1Department of Medicine, Divisions of Critical Care and Pulmonology, University of the Witwatersrand, Johannesburg, South Africa; 2Office of the Dean, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa; 3Scientific Affairs Department, Triclinium Clinical Development (Pty Ltd, Centurion, South Africa Introduction: Clinicians’ skepticism, fueled by evidence of inferiority of some multisource generic antimicrobial products, results in the underutilization of more cost-effective generics, especially in critically ill patients. The aim of this observational study was to demonstrate equivalence between the generic or comparator brand of meropenem (Mercide® and the leading innovator brand (Meronem® by means of an ex vivo technique whereby antimicrobial activity is used to estimate plasma concentration of the active moiety. Methods: Patients from different high care and intensive care units were recruited for observation when prescribed either of the meropenem brands under investigation. Blood samples were collected over 6 hours after a 30 minute infusion of the different brands. Meropenem concentration curves were established against United States Pharmacopeia standard meropenem (Sigma-Aldrich by using standard laboratory techniques for culture of Klebsiella pneumoniae. Patients’ plasma samples were tested ex vivo, using a disc diffusion assay, to confirm antimicrobial activity and estimate plasma concentrations of the two brands. Results: Both brands of meropenem demonstrated similar curves in donor plasma when concentrations in vials were confirmed. Patient-specific serum concentrations were determined from zones of inhibition against a standard laboratory Klebsiella strain ex vivo, confirming at least similar in vivo concentrations as the concentration curves (90% confidence interval overlapped; however

  7. Mercaptopurine metabolite levels are predictors of bone marrow toxicity following high-dose methotrexate therapy of childhood acute lymphoblastic leukaemia

    DEFF Research Database (Denmark)

    Vang, Sophia Ingeborg; Schmiegelow, Kjeld; Frandsen, Thomas

    2015-01-01

    High-dose methotrexate (HD-MTX) courses with concurrent oral low-dose MTX/6-mercaptopurine (6MP) for childhood acute lymphoblastic leukaemia (ALL) are often followed by neutro- and thrombocytopenia necessitating treatment interruptions. Plasma MTX during HD-MTX therapy guides folinic acid rescue ...

  8. High-dose statin therapy in patients with stable coronary artery disease: treating the right patients based on individualized prediction of treatment effect

    NARCIS (Netherlands)

    Dorresteijn, Johannes A. N.; Boekholdt, S. Matthijs; van der Graaf, Yolanda; Kastelein, John J. P.; LaRosa, John C.; Pedersen, Terje R.; Demicco, David A.; Ridker, Paul M.; Cook, Nancy R.; Visseren, Frank L. J.

    2013-01-01

    Clinicians need to identify coronary artery disease patients for whom the benefits of high-dose versus usual-dose statin therapy outweigh potential harm. We therefore aimed to develop and validate a model for prediction of the incremental treatment effect of high-dose statins for individual patients

  9. Doses to Carotid Arteries After Modern Radiation Therapy for Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Maraldo, M.V.; Brodin, Nils Patrik; Aznar, Marianne Camille

    2013-01-01

    Hodgkin lymphoma (HL) survivors are at an increased risk of stroke because of carotid artery irradiation. However, for early-stage HL involved node radiation therapy (INRT) reduces the volume of normal tissue exposed to high doses. Here, we evaluate 3-dimensional conformal radiation therapy (3D......-CRT), volumetric-modulated arc therapy (VMAT), and proton therapy (PT) delivered as INRT along with the extensive mantle field (MF) by comparing doses to the carotid arteries and corresponding risk estimates....

  10. SU-F-J-45: Sparing Normal Tissue with Ultra-High Dose Rate in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Y [DCH Reg. Medical Center, Tuscaloosa, AL (United States)

    2016-06-15

    Purpose: To spare normal tissue by reducing the location uncertainty of a moving target, we proposed an ultra-high dose rate system and evaluated. Methods: High energy electrons generated with a linear accelerator were injected into a storage ring to be accumulated. The number of the electrons in the ring was determined based on the prescribed radiation dose. The dose was delivered within a millisecond, when an online imaging system found that the target was in the position that was consistent with that in a treatment plan. In such a short time period, the displacement of the target was negligible. The margin added to the clinical target volume (CTV) could be reduced that was evaluated by comparing of volumes between CTV and ITV in 14 cases of lung stereotactic body radiation therapy (SBRT) treatments. A design of the ultra-high dose rate system was evaluated based clinical needs and the recent developments of low energy (a few MeV) electron storage ring. Results: This design of ultra-high dose rate system was feasible based on the techniques currently available. The reduction of a target volume was significant by reducing the margin that accounted the motion of the target. ∼50% volume reduction of the internal target volume (ITV) could be achieved in lung SBRT treatments. Conclusion: With this innovation of ultra-high dose rate system, the margin of target is able to be significantly reduced. It will reduce treatment time of gating and allow precisely specified gating window to improve the accuracy of dose delivering.

  11. Short-Term Therapy with High Dose Atorvastatin in Patients with Coronary Artery Disease Can Reduce Inflammatory Process

    Directory of Open Access Journals (Sweden)

    Vida Nesar Hossein

    2010-08-01

    Full Text Available Coronary heart disease is the leading cause of death and disability in adults. The association between acute coronary syndrom (ACS and elevated serum high sensitivity c-reactive protein (hsCRP suggests that chronic inflammation of the coronary arterial wall may play an important role. A number of drugs used in the treatment of cardiovascular disease reduce serum CRP. It* is therefore possible that reduced inflammation contributes to the beneficial effects of these medications. This was a double blind randomized clinical trial on 52 patients were admitted because of ACS at the Mazandaran Heart Center, Iran in 2007. The patients were divided to three randomized groups which received 20, 40, 80* mg Atorvastatin daily for 6 months. At the time of study enrollment and 1, 3 and 6 months after initiation hsCRP were measured. 1 and 3 month after 20mg atorvastatin therapy the median serum concentration of hsCRP did not decrease significantly, but at the end of 6th month it was* significant difference. At 40mg dosage from 3th month to 6th month versus 1st month to 3th month it was significant decrease, at the end of 1th month and 3rd month it was not significant. At 80mg dose at the end of 1th month it was not significant but at the* end of 3th month and end of 6th month it was significant. Intensive lipid-lowering therapy with high-dose atorvastatin therapy relative to moderate lipid-lowering therapy with low-dose atorvastatin reduces hsCRP better. We found that treatment with greater dose of atorvastatin might decrease greater in plasma level of hsCRP.

  12. On the genetic risk after high dose radioiodine therapy with regard to the gonadal dose

    International Nuclear Information System (INIS)

    Ehrenheim, C.; Hauswirth, C.; Fitschen, J.; Martin, E.; Oetting, G.; Hundeshagen, H.

    1997-01-01

    Aim: The genetic risk for the offspring of patients treated with high doses of radioiodine was to be assessed with special regard to the gonadal dose caused by diagnostic and therapeutic procedures. Methods: 41 young females (aged between 19 and 39 years) and four young males (aged 26 to 36 years) treated with radioiodine because of a thyroid carcinoma were interviewed by use of a questionnaire. The course of pregnancy and birth history could be documented as well as the congenital and developmental conditions of 56 children. Results: The amount of radioactivity applied for therapy and whole body scans ranged over 4,144 and 35,15 GBq I-131; the individual gonadal dose was calculated based on the MIRD model and ranged over 0,2 and 2,2 Sv (0,51 Sv at a mean). The period of time between the last radioiodine application and confinement was at least 9 months, not exceeding 14 years. As to the course of pregnancy and birth two early abortions, one extrauterine gravidity and one premature birth due to an insufficiency of the placenta were stated. In one case a chromosomal translocation 7/14 occured as a genetic defect which lead to an interruption. The children's development was unconspicuous except of two cases of neurodermatitis as well as multiple allergies and an early closure of the anterior fontanelle in one child each. Conclusion: Although the genetic risk is supposed to increase with the gonadal dose achieved (doubling dose 1 Sv) and the increased risk of any congenital anomaly was calculated as about 13% at a mean in our patients, the rate of genetic determined diseases was not elevated (1,8% or 1/57). Thus, no increase of genetic defects or congenital malformations was reported in a total of 408 children described in the literature and in our group. (orig.) [de

  13. Pentobarbital quantitation using EMIT serum barbiturate assay reagents: application to monitoring of high-dose pentobarbital therapy.

    Science.gov (United States)

    Pape, B E; Cary, P L; Clay, L C; Godolphin, W

    1983-01-01

    Pentobarbital serum concentrations associated with a high-dose therapeutic regimen were determined using EMIT immunoassay reagents. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of 5.0% and a between-assay coefficient of variation of 10%. Regression analysis of 44 serum samples analyzed by this technique (y) and a reference procedure (x) were y = 0.98x + 3.6 (r = 0.98; x = ultraviolet spectroscopy) and y = 1.04x + 2.4 (r = 0.96; x = high-performance liquid chromatography). Clinical evaluation of the results indicates the immunoassay is sufficiently sensitive and selective for pentobarbital to allow accurate quantitation within the therapeutic range associated with high-dose therapy.

  14. Small bowel toxicity after high dose spot scanning-based proton beam therapy for paraspinal/retroperitoneal neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, R.A.; Albertini, F.; Koch, T.; Ares, C.; Lomax, A.; Goitein, G. [Paul Scherrer Institute PSI, Villigen (Switzerland). Center for Proton Therapy; Vitolo, V. [Fondazione CNAO, Pavia (Italy); Hug, E.B. [Paul Scherrer Institute PSI, Villigen (Switzerland). Center for Proton Therapy; ProCure Proton Therapy Centers, New York, NY (United States)

    2013-12-15

    Purpose: Mesenchymal tumours require high-dose radiation therapy (RT). Small bowel (SB) dose constraints have historically limited dose delivery to paraspinal and retroperitoneal targets. This retrospective study correlated SB dose-volume histograms with side-effects after proton radiation therapy (PT). Patients and methods: Between 1997 and 2008, 31 patients (mean age 52.1 years) underwent spot scanning-based PT for paraspinal/retroperitoneal chordomas (81 %), sarcomas (16 %) and meningiom (3 %). Mean total prescribed dose was 72.3 Gy (relative biologic effectiveness, RBE) delivered in 1.8-2 Gy (RBE) fractions. Mean follow-up was 3.8 years. Based on the pretreatment planning CT, SB dose distributions were reanalysed. Results: Planning target volume (PTV) was defined as gross tumour volume (GTV) plus 5-7 mm margins. Mean PTV was 560.22 cm{sup 3}. A mean of 93.2 % of the PTV was covered by at least 90 % of the prescribed dose. SB volumes (cm{sup 3}) receiving doses of 5, 20, 30, 40, 50, 60, 70, 75 and 80 Gy (RBE) were calculated to give V5, V20, V30, V40, V50, V60, V70, V75 and V80 respectively. In 7/31 patients, PT was accomplished without any significant SB irradiation (V5 = 0). In 24/31 patients, mean maximum dose (Dmax) to SB was 64.1 Gy (RBE). Despite target doses of > 70 Gy (RBE), SB received > 50 and > 60 Gy (RBE) in only 61 and 54 % of patients, respectively. Mean SB volumes (cm{sup 3}) covered by different dose levels (Gy, RBE) were: V20 (n = 24): 45.1, V50 (n = 19): 17.7, V60 (n = 17): 7.6 and V70 (n = 12): 2.4. No acute toxicity {>=} grade 2 or late SB sequelae were observed. Conclusion: Small noncircumferential volumes of SB tolerated doses in excess of 60 Gy (RBE) without any clinically-significant late adverse effects. This small retrospective study has limited statistical power but encourages further efforts with higher patient numbers to define and establish high-dose threshold models for SB toxicity in modern radiation oncology. (orig.)

  15. Brachial Plexus-Associated Neuropathy After High-Dose Radiation Therapy for Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Chen, Allen M.; Hall, William H.; Li, Judy; Beckett, Laurel; Farwell, D. Gregory; Lau, Derick H.; Purdy, James A.

    2012-01-01

    Purpose: To identify clinical and treatment-related predictors of brachial plexus–associated neuropathies after radiation therapy for head-and-neck cancer. Methods and Materials: Three hundred thirty patients who had previously completed radiation therapy for head-and-neck cancer were prospectively screened using a standardized instrument for symptoms of neuropathy thought to be related to brachial plexus injury. All patients were disease-free at the time of screening. The median time from completion of radiation therapy was 56 months (range, 6–135 months). One-hundred fifty-five patients (47%) were treated by definitive radiation therapy, and 175 (53%) were treated postoperatively. Radiation doses ranged from 50 to 74 Gy (median, 66 Gy). Intensity-modulated radiation therapy was used in 62% of cases, and 133 patients (40%) received concurrent chemotherapy. Results: Forty patients (12%) reported neuropathic symptoms, with the most common being ipsilateral pain (50%), numbness/tingling (40%), motor weakness, and/or muscle atrophy (25%). When patients with <5 years of follow-up were excluded, the rate of positive symptoms increased to 22%. On univariate analysis, the following factors were significantly associated with brachial plexus symptoms: prior neck dissection (p = 0.01), concurrent chemotherapy (p = 0.01), and radiation maximum dose (p < 0.001). Cox regression analysis confirmed that both neck dissection (p < 0.001) and radiation maximum dose (p < 0.001) were independently predictive of symptoms. Conclusion: The incidence of brachial plexus–associated neuropathies after radiation therapy for head-and-neck cancer may be underreported. In view of the dose–response relationship identified, limiting radiation dose to the brachial plexus should be considered when possible.

  16. High-dose therapy improved the bone remodelling compartment canopy and bone formation in multiple myeloma

    DEFF Research Database (Denmark)

    Hinge, Maja; Delaissé, Jean-Marie; Plesner, Torben

    2015-01-01

    transplantation, and from 20 control patients with monoclonal gammopathy of undetermined significance were histomorphometrically investigated. This investigation confirmed that MM patients exhibited uncoupled bone formation to resorption and reduced canopy coverage. More importantly, this study revealed......Bone loss in multiple myeloma (MM) is caused by an uncoupling of bone formation to resorption trigged by malignant plasma cells. Increasing evidence indicates that the bone remodelling compartment (BRC) canopy, which normally covers the remodelling sites, is important for coupled bone remodelling....... Loss of this canopy has been associated with bone loss. This study addresses whether the bone remodelling in MM is improved by high-dose therapy. Bone marrow biopsies obtained from 20 MM patients, before and after first-line treatment with high-dose melphalan followed by autologous stem cell...

  17. Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Rawlinson, J. Alan; Islam, Mohammad K.; Galbraith, Duncan M.

    2002-01-01

    The increased beam-on times which characterize intensity-modulated radiation therapy (IMRT) could lead to an increase in the dose received by radiation therapists due to induced activity. To examine this, gamma ray spectrometry was used to identify the major isotopes responsible for activation at a representative location in the treatment room of an 18 MV accelerator (Varian Clinac 21EX). These were found to be 28 Al, 56 Mn, and 24 Na. The decay of the dose rate measured at this location following irradiation was analyzed in terms of the known half-lives to yield saturation dose rates of 9.6, 12.4, and 6.2 μSv/h, respectively. A formalism was developed to estimate activation dose (μSv/week) due to successive patient irradiation cycles, characterized by the number of 18 MV fractions per week, F, the number of MU per fraction, M, the in-room time between fractions, t d (min), and the treatment delivery time t r ' (min). The results are represented by the sum of two formulas, one for the dose from 28 Al≅1.8x10 -3 F M (1-e -0.3t r ' )/t r ' and one for the dose from the other isotopes ≅1.1x10 -6 F 1.7 Mt d . For conventional therapy doses are about 60 μ Sv/week for an 18 MV workload of 60 000 MU/week. Irradiation for QA purposes can significantly increase the dose. For IMRT as currently practiced, lengthy treatment delivery times limit the number of fractions that can be delivered per week and hence limit the dose to values similar to those in conventional therapy. However for an IMRT regime designed to maximize patient throughput, doses up to 330 μSv/week could be expected. To reduce dose it is recommended that IMRT treatments should be delivered at energies lower than 18 MV, that in multienergy IMRT, high-energy treatments should be scheduled in the latter part of the day, and that equipment manufacturers should strive to minimize activation in the design of high-energy accelerators

  18. Impact of Dose to the Bladder Trigone on Long-Term Urinary Function After High-Dose Intensity Modulated Radiation Therapy for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ghadjar, Pirus; Zelefsky, Michael J.; Spratt, Daniel E. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Munck af Rosenschöld, Per; Oh, Jung Hun; Hunt, Margie [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Kollmeier, Marisa [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Happersett, Laura; Yorke, Ellen; Deasy, Joseph O. [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Jackson, Andrew, E-mail: jacksona@mskcc.org [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2014-02-01

    Purpose: To determine the potential association between genitourinary (GU) toxicity and planning dose–volume parameters for GU pelvic structures after high-dose intensity modulated radiation therapy in localized prostate cancer patients. Methods and Materials: A total of 268 patients who underwent intensity modulated radiation therapy to a prescribed dose of 86.4 Gy in 48 fractions during June 2004-December 2008 were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Dose–volume histograms of the whole bladder, bladder wall, urethra, and bladder trigone were analyzed. The primary endpoint for GU toxicity was an IPSS sum increase ≥10 points over baseline. Univariate and multivariate analyses were done by the Kaplan-Meier method and Cox proportional hazard models, respectively. Results: Median follow-up was 5 years (range, 3-7.7 years). Thirty-nine patients experienced an IPSS sum increase ≥10 during follow-up; 84% remained event free at 5 years. After univariate analysis, lower baseline IPSS sum (P=.006), the V90 of the trigone (P=.006), and the maximal dose to the trigone (P=.003) were significantly associated with an IPSS sum increase ≥10. After multivariate analysis, lower baseline IPSS sum (P=.009) and increased maximal dose to the trigone (P=.005) remained significantly associated. Seventy-two patients had both a lower baseline IPSS sum and a higher maximal dose to the trigone and were defined as high risk, and 68 patients had both a higher baseline IPSS sum and a lower maximal dose to the trigone and were defined as low risk for development of an IPSS sum increase ≥10. Twenty-one of 72 high-risk patients (29%) and 5 of 68 low-risk patients (7%) experienced an IPSS sum increase ≥10 (P=.001; odds ratio 5.19). Conclusions: The application of hot spots to the bladder trigone was significantly associated with relevant changes in IPSS during follow-up. Reduction of radiation dose to the lower bladder and specifically the

  19. Validation of GPU based TomoTherapy dose calculation engine.

    Science.gov (United States)

    Chen, Quan; Lu, Weiguo; Chen, Yu; Chen, Mingli; Henderson, Douglas; Sterpin, Edmond

    2012-04-01

    The graphic processing unit (GPU) based TomoTherapy convolution/superposition(C/S) dose engine (GPU dose engine) achieves a dramatic performance improvement over the traditional CPU-cluster based TomoTherapy dose engine (CPU dose engine). Besides the architecture difference between the GPU and CPU, there are several algorithm changes from the CPU dose engine to the GPU dose engine. These changes made the GPU dose slightly different from the CPU-cluster dose. In order for the commercial release of the GPU dose engine, its accuracy has to be validated. Thirty eight TomoTherapy phantom plans and 19 patient plans were calculated with both dose engines to evaluate the equivalency between the two dose engines. Gamma indices (Γ) were used for the equivalency evaluation. The GPU dose was further verified with the absolute point dose measurement with ion chamber and film measurements for phantom plans. Monte Carlo calculation was used as a reference for both dose engines in the accuracy evaluation in heterogeneous phantom and actual patients. The GPU dose engine showed excellent agreement with the current CPU dose engine. The majority of cases had over 99.99% of voxels with Γ(1%, 1 mm) engine also showed similar degree of accuracy in heterogeneous media as the current TomoTherapy dose engine. It is verified and validated that the ultrafast TomoTherapy GPU dose engine can safely replace the existing TomoTherapy cluster based dose engine without degradation in dose accuracy.

  20. Dose and volume specification for reporting interstitial therapy

    International Nuclear Information System (INIS)

    1997-01-01

    The ICRU has previously published reports dealing with Dose Specification for Reporting External Beam Therapy with Photons and Electrons (ICRU Report 29, ICRU, 1978), Dose Specification for Reporting External Beam Therapy (ICRU Report 50, ICRU, 1993) and Dose and Volume Specification for Reporting Intracavitary Therapy in Gynecology (ICRU Report 38, ICRU, 1985). The present report addresses the problem of absorbed dose specification for report interstitial therapy. Although specific to interstitial therapy, many of the concepts developed in this report are also applicable to certain other kinds of brachytherapy applications. In particular, special cases of intraluminal brachytherapy and plesio-brachytherapy via surface molds employing x or gamma emitters are addressed in this report

  1. High-dose erythropoietin for tissue protection

    DEFF Research Database (Denmark)

    Lund, Anton; Lundby, Carsten; Olsen, Niels Vidiendal

    2014-01-01

    BACKGROUND: The discovery of potential anti-apoptotic and cytoprotective effects of recombinant human erythropoietin (rHuEPO) has led to clinical trials investigating the use of high-dose, short-term rHuEPO therapy for tissue protection in conditions such as stroke and myocardial infarction....... Experimental studies have been favourable, but the clinical efficacy has yet to be validated. MATERIALS AND METHODS: We have reviewed clinical studies regarding the use of high-dose, short-term rHuEPO therapy for tissue protection in humans with the purpose to detail the safety and efficacy of r...... no effect of rHuEPO therapy on measures of tissue protection. Five trials including 1025 patients reported safety concerns in the form of increased mortality or adverse event rates. No studies reported reduced mortality. CONCLUSIONS: Evidence is sparse to support a tissue-protective benefit of r...

  2. High-dose preoperative radiation for cancer of the rectum: Impact of radiation dose on patterns of failure and survival

    International Nuclear Information System (INIS)

    Ahmad, N.R.; Mohiuddin, M.; Marks, G.

    1993-01-01

    A variety of dose-time schedules are currently used for preoperative radiation therapy of rectal cancer. An analysis of patients treated with high-dose preoperative radiation therapy was undertaken to determine the influence of radiation dose on the patterns of failure, survival, and complications. Two hundred seventy-five patients with localized rectal cancer were treated with high-dose preoperative radiation therapy. One hundred fifty-six patients received 45 Gy (low-dose group). Since 1985, 119 patients with clinically unfavorable cancers were given a higher dose, 55 Gy using a shrinking field technique (high-dose group). All patients underwent curative resection. Median follow-up was 66 months in the low-dose group and 28 months in the high-dose group. Patterns of failure, survival, and complications were analyzed as a function of radiation dose. Fourteen percent of the total group developed a local recurrence; 20% in the low-dose group as compared with 6% in the high-dose group. The actuarial local recurrence rate at 5 years was 20% for the low-dose group and 8% for the high-dose group, and approached statistical significance with p = .057. For tethered/fixed tumors the actuarial local recurrence rates at 5 years were 28% and 9%, respectively, with p = .05. Similarly, for low-lying tumors (less than 6 cm from the anorectal junction) the rates were 24% and 9%, respectively, with p = .04. The actuarial rate of distant metastasis was 28% in the low-dose group and 20% in the high-dose group and was not significantly different. Overall actuarial 5-year survival for the total group of patients was 66%. No significant difference in survival was observed between the two groups, despite the higher proportion of unfavorable cancers in the high-dose group. The incidence of complications was 2%, equally distributed between the two groups. High-dose preoperative radiation therapy for rectal cancer results in excellent local control rates. 27 refs., 2 figs., 8 tabs

  3. Dose-volume considerations in stereotaxic brain radiation therapy

    International Nuclear Information System (INIS)

    Houdek, P.V.; Schwade, J.G.; Pisciotta, V.J.; Medina, A.J.; Lewin, A.A.; Abitbol, A.A.; Serago, C.F.

    1988-01-01

    Although brain radiation therapy experience suggests that a gain in the therapeutic ratio may be achieved by optimizing the dose-volume relationship, no practical system for quantitative assessment of dose-volume data has been developed. This presentation describes the rationale for using the integral dose function for this purpose and demonstrates that with the use of a conventional treatment planning computer and a series of computed tomographic scans, first-order optimization of the dose-volume function can be accomplished in two steps: first, high-dose volume is minimized by selecting an appropriate treatment technique and tumor margin, and then dosage is maximized by calculating the brain tolerance dose as a function of the irradiated volume

  4. Radiation therapy of malignant melanoma: Experience with high individual treatment doses

    International Nuclear Information System (INIS)

    Habermalz, H.J.; Fischer, J.J.

    1984-01-01

    Melanoma is a complex tumor, metastasizes early both by lymphatic and blood vessels, and which may invoke a significant host ''immune,'' response. One can imagine a number of potentially useful roles for an effective radiation therapy regimen: 1. Treatment of the primary lesion. For small lesions located on the extremities, surgery may be simpler and obviate the risk of radiation failure. In other areas, e.g., head and neck, which may require more cosmetically or functionally debilitating surgery, a trial of radiation therapy may be worthwhile. 2. Preoperative radiation to the primary lesion before surgical resection in the hope of preventing tumor dissemination. 3. Prophylactic, local and regional lymph node radiation therapy. It has been popular in the past to remove malignant melanoma with wide local excision and dissection of adjacent node areas. It is still an open question whether some or any additional patients will be cured by the more vigorous local and extended treatment. Generally, those procedures have fallen into disfavor because of the associated morbidity. Presumably subclinical amounts of malignant melanoma could be sterilized with doses of radiation smaller than those necessary for bulk tumor. Wide field irradiation to the areas surrounding the primary lesion and the adjacent lymph nodes, to doses causing little morbidity, may well be worth clinical trial. 4. In combination with other forms of therapy, e.g., chemotherapy, immunotherapy, hyperthermia, to reduce the number of malignant cells in localized areas known to contain diseases. This may be particularly important prior to initiation of immunotherapy which may be much more effective in the absence of gross disease

  5. Neuropsychological function in adults after high dose fractionated radiation therapy of skull base tumors

    International Nuclear Information System (INIS)

    Glosser, Guila; McManus, Pat; Munzenrider, John; Austin-Seymour, Mary; Fullerton, Barbara; Adams, Judy; Urie, Marcia M.

    1997-01-01

    Purpose: To evaluate the long term effects of high dose fractionated radiation therapy on brain functioning prospectively in adults without primary brain tumors. Methods and Materials: Seventeen patients with histologically confirmed chordomas and low grade chondrosarcomas of the skull base were evaluated with neuropsychological measures of intelligence, language, memory, attention, motor function and mood following surgical resection/biopsy of the tumor prior to irradiation, and then at about 6 months, 2 years and 4 years following completion of treatment. None received chemotherapy. Results: In the patients without tumor recurrence or radiation necrosis, there were no indications of adverse effects on cognitive functioning in the post-acute through the late stages after brain irradiation. Even in patients who received doses of radiation up to 66 Cobalt Gy equivalent through nondiseased (temporal lobe) brain tissue, memory and cognitive functioning remained stable for up to 5 years after treatment. A mild decline in psycho-motor speed was seen in more than half of the patients, and motor slowing was related to higher radiation doses in midline and temporal lobe brain structures. Conclusion: Results suggest that in adults, tolerance for focused radiation is relatively high in cortical brain structures

  6. Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, Martin A., E-mail: Martin.Ebert@health.wa.gov.au [Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); School of Physics, University of Western Australia, Perth, Western Australia (Australia); Foo, Kerwyn [Sydney Medical School, University of Sydney, Sydney, New South Wales (Australia); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne, Victoria (Australia); Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria (Australia); Gulliford, Sarah L. [Joint Department of Physics, Institute of Cancer Research and Royal Marsden National Health Service Foundation Trust, Sutton, Surrey (United Kingdom); Kennedy, Angel [Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); Joseph, David J. [Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); School of Surgery, University of Western Australia, Perth, Western Australia (Australia); Denham, James W. [School of Medicine and Public Health, University of Newcastle, Newcastle, New South Wales (Australia)

    2015-03-01

    Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for

  7. Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

    International Nuclear Information System (INIS)

    Ebert, Martin A.; Foo, Kerwyn; Haworth, Annette; Gulliford, Sarah L.; Kennedy, Angel; Joseph, David J.; Denham, James W.

    2015-01-01

    Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for

  8. Maximal safe dose therapy of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Lee, Jong Jin; Seok, Ju Won; Uh, Jae Sun

    2005-01-01

    In patients with recurrent or metastatic differentiated thyroid carcinoma, residual disease despite repetitive fixed dose I-131 therapy presents an awkward situation in terms of treatment decision making. Maximal safe dose (MSD) administration base on bone marrow radiation allows the delivery of a large amount I-131 to thyroid cancer tissue within the safety margin. We investigated the efficacy of MSD in differentiated thyroid cancers, which had persisted after conventional fixed dose therapy. Forty-six patients with differentiated thyroid carcinoma who had non-responsible residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. The postoperative pathology consisted of 43 papillary carcinomas and 3 follicular carcinomas. MSD was calculated according the Memorial Sloan Kettering Cancer Center protocol using blood samples. MSDs were administered at intervals of at least 6 months. Treatment responses were evaluated using I-131 whole body scan (WBS) and serum thyroglobulin measurements. Mean calculated MSD was 12.5±2.1 GBq. Of the 46 patients, 6 (13.0%) showed complete remission, 15 (32.6%) partial response, 19 (41.3%) stable disease, and 6 (13.0%) disease progression. Thus, about a half of the patients showed complete or partial remission, and of these patients, 14 (67%) showed response after a single MSD administration and 6 (29%) showed response after the second dose of MSD administrations. Twenty-nine patients (63%) experienced transient cytopenia after therapy, and recovered spontaneously with the exception of one. MSD administration is an effective method even in the patients who failed to be treated by conventional fixed dose therapy. MSD therapy of I-131 can be considered in the patients who failed by fixed dose therapy

  9. Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy

    International Nuclear Information System (INIS)

    Jang, Joon Yung; Park, Soo Yun; Kim, Jong Sik; Choi, Byeong Gi; Song, Gi Won

    2011-01-01

    Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  10. Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joon Yung; Park, Soo Yun; Kim, Jong Sik; Choi, Byeong Gi; Song, Gi Won [Dept. of Radiation Oncology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-09-15

    Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  11. Comparison of effectiveness and safety of imipenem/clavulanate- versus meropenem/clavulanate-containing regimens in the treatment of MDR- and XDR-TB.

    Science.gov (United States)

    Tiberi, Simon; Sotgiu, Giovanni; D'Ambrosio, Lia; Centis, Rosella; Abdo Arbex, Marcos; Alarcon Arrascue, Edith; Alffenaar, Jan Willem; Caminero, Jose A; Gaga, Mina; Gualano, Gina; Skrahina, Alena; Solovic, Ivan; Sulis, Giorgia; Tadolini, Marina; Alarcon Guizado, Valentina; De Lorenzo, Saverio; Roby Arias, Aurora Jazmín; Scardigli, Anna; Akkerman, Onno W; Aleksa, Alena; Artsukevich, Janina; Auchynka, Vera; Bonini, Eduardo Henrique; Chong Marín, Félix Antonio; Collahuazo López, Lorena; de Vries, Gerard; Dore, Simone; Kunst, Heinke; Matteelli, Alberto; Moschos, Charalampos; Palmieri, Fabrizio; Papavasileiou, Apostolos; Payen, Marie-Christine; Piana, Andrea; Spanevello, Antonio; Vargas Vasquez, Dante; Viggiani, Pietro; White, Veronica; Zumla, Alimuddin; Migliori, Giovanni Battista

    2016-06-01

    No large study to date has ever evaluated the effectiveness, safety and tolerability of imipenem/clavulanate versus meropenem/clavulanate to treat multidrug- and extensively drug-resistant tuberculosis (MDR- and XDR-TB). The aim of this observational study was to compare the therapeutic contribution of imipenem/clavulanate versus meropenem/clavulanate added to background regimens to treat MDR- and XDR-TB cases.84 patients treated with imipenem/clavulanate-containing regimens showed a similar median number of antibiotic resistances (8 versus 8) but more fluoroquinolone resistance (79.0% versus 48.9%, pimipenem/clavulanate- and meropenem/clavulanate-containing regimens for a median (interquartile range) of 187 (60-428) versus 85 (49-156) days, respectively.Statistically significant differences were observed on sputum smear and culture conversion rates (79.7% versus 94.8%, p=0.02 and 71.9% versus 94.8%, pimipenem/clavulanate and meropenem/clavulanate were reported in 5.4% and 6.5% of cases only.Our study suggests that meropenem/clavulanate is more effective than imipenem/clavulanate in treating MDR/XDR-TB patients. Copyright ©ERS 2016.

  12. High-dose buprenorphine: perioperative precautions and management strategies.

    Science.gov (United States)

    Roberts, D M; Meyer-Witting, M

    2005-02-01

    Buprenorphine has been in clinical use in anaesthesia for several decades. Recently, the high-dose sublingual formulation (Subutex, Reckitt Benckiser, Slough, U.K.) has been increasingly used as maintenance therapy in opioid dependence, as an alternative to methadone and other pharmacological therapies. Buprenorphine has unique pharmacological properties making it well suited for use as a maintenance therapy in opioid dependence. However, these same properties may cause difficulty in the perioperative management of pain. Buprenorphine is a partial opioid agonist, attenuating the effects of supplemental illicit or therapeutic opioid agonists. As a result of its high receptor affinity, supplemental opioids do not readily displace buprenorphine from the opioid receptor in standard doses. High-dose buprenorphine has an extended duration of action that prolongs both of these effects. The perioperative management of patients stabilized on high-dose buprenorphine and undergoing surgery requires consideration of the likely analgesic requirements. Where possible the buprenorphine should be continued. Pain management should focus on maximizing non-opioid analgesia, local anaesthesia and non-pharmacological techniques. Where pain may not be adequately relieved by these methods, the addition of a full opioid agonist such as fentanyl or morphine at appropriate doses should be considered, accompanied by close monitoring in a high dependency unit. In situations where this regimen is unlikely to be effective, preoperative conversion to morphine or methadone may be an option. Where available, liaison with a hospital-based alcohol and drug service should always be considered.

  13. The anti-Pseudomonas aeruginosa antibody Panobacumab is efficacious on acute pneumonia in neutropenic mice and has additive effects with meropenem.

    Directory of Open Access Journals (Sweden)

    Thomas Secher

    Full Text Available Pseudomonas aeruginosa (P. aeruginosa infections are associated with considerable morbidity and mortality in immunocompromised patients due to antibiotic resistance. Therefore, we investigated the efficacy of the anti-P. aeruginosa serotype O11 lipopolysaccharide monoclonal antibody Panobacumab in a clinically relevant murine model of neutropenia induced by cyclophosphamide and in combination with meropenem in susceptible and meropenem resistant P. aeruginosa induced pneumonia. We observed that P. aeruginosa induced pneumonia was dramatically increased in neutropenic mice compared to immunocompetent mice. First, Panobacumab significantly reduced lung inflammation and enhanced bacterial clearance from the lung of neutropenic host. Secondly, combination of Panobacumab and meropenem had an additive effect. Third, Panobacumab retained activity on a meropenem resistant P. aeruginosa strain. In conclusion, the present data established that Panobacumab contributes to the clearance of P. aeruginosa in neutropenic hosts as well as in combination with antibiotics in immunocompetent hosts. This suggests beneficial effects of co-treatment even in immunocompromised individuals, suffering most of the morbidity and mortality of P. aeruginosa infections.

  14. Intracranial meningiomas after high-dose irradiation

    International Nuclear Information System (INIS)

    Soffer, D.; Gomori, J.M.; Siegal, T.; Shalit, M.N.

    1989-01-01

    Three patients who presented with intracranial meningiomas 12, 15, and 20 years, respectively, after therapeutic high-dose irradiation of a primary brain tumor are described. Analysis of these cases and similar documented cases suggests that meningiomas after high-dose irradiation constitute a recognizable entity. Patients with such tumors received radiation therapy at a young age (mean age, 9.4 years). After a latent period of 2 to 47 years (mean, 19.8 years) they developed meningiomas at the site of irradiation, at a much younger age than patients with ''spontaneous'' meningiomas. Similar to the situation with meningiomas after low-dose irradiation, a relatively high proportion of meningiomas induced by high-dose irradiation tend to be malignant and biologically aggressive. A very young age at the time of irradiation seems to predispose to the induction of malignant meningiomas, rather than benign tumors. These unusual features provide indirect evidence that high-dose radiation may play a role in the pathogenesis of meningiomas.41 references

  15. CD34-positive cells as stem cell support after high dose therapy

    International Nuclear Information System (INIS)

    Kvalheim, G.; Pharo, A.; Holte, H.

    1996-01-01

    Six patients, five with breast cancer and one with non-Hodgkin's lymphoma, were mobilized by chemotherapy and G-CSF. CD34-positive cells were isolated by means of immunomagnetic beads and Isolex 300 Cell Separator. Mean purity of isolated CD34-positive cells was 97% and mean yield was 54%. Three patients were treated with high dose therapy followed by reinfusion of CD34-positive cells as stem cell support. Recovery of neutrophils occurred at day 8, 11 and 13 and of platelets at day 9, 14 and 32. It is concluded that immunomagnetic isolated CD34-positive cells give high purity and yield. Although use of CD34-positive cells reduces the content of contaminating tumours cells in the graft, breast cancer cells were still detectable in two out of five CD34-positive cell products. 20 refs., 2 figs., 1 tab

  16. Functional impairment of the salivary gland after high dose radioiodine therapy

    Energy Technology Data Exchange (ETDEWEB)

    Spiegel, W.; Reiners, C.; Boerner, W.

    1986-06-01

    Radiation induced impairements of salivation, which are rather related to the more radio-sensitive parotides than to the submandibular glands according to our experience, occur in about 1/3 of the patients treated with 7,4-11,1 GBq (200-300 mCi) of I-131. Based on our results and experiences after percutaneous radiation therapy of the head and neck region, a total xerostomy (Sicca's syndrome) must already be expected at a focal dose of 40 Gy to the salivary gland parenchyma. Experience has shown that this cumulative radiation dose is reached at about 18,5 GBq (500 mCi) of I-131. The acute sialadenitis occuring a few days after therapeutic administration of radioiodine is mostly associated with minor complaints and therefore often escapes the patient's notice. During the onset of xerostomy, which is associated with a moderate reduction of salivation, the patients are surprisingly indolent. However, specific examinations including patient's history, palpation and functional scintigraphy enable early detection of radiation induced functional depression of the salivary glands, which should be accounted for in the assessment of indication for further radioiodine therapy. To prevent the severe consequences of xerostomy such as ageusia, dysphagia, epithelial lesion of the oral mucosa and loss of teeth, the patients under radioiodine therapy should be urged to see to sufficient fluid supply and to steadily stimulate salivation e.g. by sour drops, chewing gum or Emser pastilles.

  17. Low dose iodine-131 therapy in solitary toxic thyroid nodules

    International Nuclear Information System (INIS)

    Prakash, Rajeev

    1999-01-01

    Forty patients with solitary hyperfunctioning thyroid nodules were treated with relatively low dose radioiodine therapy, 131 I doses were calculated taking into account thyroid mass and radioiodine kinetics to deliver 100 μCi/g of estimated nodule weight corrected for uptake. Patients remaining persistently hyperthyroid at four months after the initial therapy were retreated with a similarly calculated dose. Cure of the hyperthyroid state was achieved in all patients, total administered dose in individual cases ranging from 3-17 mCi. 28 of the 40 patients required a single therapy dose. 36 patients were euthyroid after a 4.5 year mean follow-up period. Four cases developed post therapy hypothyroidism requiring replacement therapy. Nodules regressed completely in nine cases following 131 I treatment, with partial regression in size in 19 patients. Control of hyperthyroid state in cases of solitary toxic thyroid nodules can be satisfactorily achieved using relatively low dose radioiodine therapy with low incidence of post therapy hypothyroidism. (author)

  18. Preliminary results of concurrent chemotherapy and radiation therapy using high-dose-rate brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ja; Lee, Ji Hye; Lee, Re Na; Suh, Hyun Suk [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34 {approx} 74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follow: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45 {approx} 50.4 Gy (median: 50.4 Gy) over 5 {approx} 5.5 weeks. Ir-192 HDR intracavity brachytherapy (ICBT) was given after a total dose of 41.1 Gy. HDR-ICBT was performed twice a week, with a fraction point. A dose of 4 Gy and median dose to point A was 28 Gy (range: 16 {approx} 32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT + ICBT) was 88 Gy{sub 10} (range:77 {approx} 94 Gy{sub 10}). The median cumulative BED at ICRU 38 reference point (EBRT + ICBT) was 131 Gy{sub 3} (range: 122 {approx} 140 Gy{sub 3}) at point A, 109 Gy{sub 3} (range:88{approx} 125 Gy{sub 3}) at the rectum and 111 Gy{sub 3} (range: 91 {approx} 123 Gy{sub 3}) at the urinary bladder. Cisplatin (60 mg/m{sup 2}) and 5-FU (1,000 mg/m{sup 2}) was administered intravenously at 2 weeks interval from the first day of radiation for median 5 (range:2 {approx} 6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range:8{approx} 50 months). The complete response rate after concurrent chemo radiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure

  19. Preliminary results of concurrent chemotherapy and radiation therapy using high-dose-rate brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Lee, Kyung Ja; Lee, Ji Hye; Lee, Re Na; Suh, Hyun Suk

    2006-01-01

    To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34 ∼ 74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follow: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45 ∼ 50.4 Gy (median: 50.4 Gy) over 5 ∼ 5.5 weeks. Ir-192 HDR intracavity brachytherapy (ICBT) was given after a total dose of 41.1 Gy. HDR-ICBT was performed twice a week, with a fraction point. A dose of 4 Gy and median dose to point A was 28 Gy (range: 16 ∼ 32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT + ICBT) was 88 Gy 10 (range:77 ∼ 94 Gy 10 ). The median cumulative BED at ICRU 38 reference point (EBRT + ICBT) was 131 Gy 3 (range: 122 ∼ 140 Gy 3 ) at point A, 109 Gy 3 (range:88∼ 125 Gy 3 ) at the rectum and 111 Gy 3 (range: 91 ∼ 123 Gy 3 ) at the urinary bladder. Cisplatin (60 mg/m 2 ) and 5-FU (1,000 mg/m 2 ) was administered intravenously at 2 weeks interval from the first day of radiation for median 5 (range:2 ∼ 6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range:8∼ 50 months). The complete response rate after concurrent chemo radiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure rate was 13% and distant metastatic rate was 3.3%. The crude rate of minor hematologic

  20. In vitro Efficacy of Meropenem, Colistin and Tigecycline Against the Extended Spectrum Beta-Lactamase Producing Gram Negative Bacilli

    International Nuclear Information System (INIS)

    Gill, M. M.; Usman, J.; Hassan, A.; Kaleem, F.; Anjum, R.

    2015-01-01

    Objective:To compare the in vitroefficacy of meropenem, colistin and tigecycline against extended spectrum Betalactamase producing Gram negative bacilli by minimal inhibitory concentration. Study Design:Cross-sectional descriptive study. Place and Duration of Study: Department of Microbiology, Army Medical College, National University of Sciences and Technology, Rawalpindi, from June to December 2010. Methodology: Routine clinical specimens were subjected to standard microbiological procedures and the isolates were identified to species level. Extended spectrum beta-lactamase producing Gram negative bacilli were detected by Jarlier disc synergy method and confirmed by ceftazidime and ceftazidime-clavulanate Etest. Minimum Inhibitory Concentration (MIC90) of meropenem, colistin and tigecycline was determined by Etest (AB BIOMERIUX) and the results were interpreted according to the manufacturer's instructions and Clinical and Laboratory Standards Institute guidelines and Food and Drug Authority recommendations. Results were analyzed by using Statistical Package for the Social Sciences version 20. Results: A total of 52 non-duplicate extended spectrum Beta-lactamase-producing Gram negative bacilli were included in the study. The MIC90 of tigecycline (0.75 micro g/ml) was lowest as compared to the meropenem (2 micro g/ml) and colistin (3 micro g/ml). Conclusion: Tigecycline is superior in efficacy against the extended spectrum Beta-lactamase producing Gram negative bacilli as compared to colistin and meropenem. (author)

  1. Comparison of dose-volume histograms for Tomo therapy, linear accelerator-based 3D conformal radiation therapy, and intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Choi, Seong-Kwan; Chung, Woon-Kwan; Lee, Jong-Woong

    2011-01-01

    Highlights: → Evaluation of DVH from 3D CRT, IMRT and Tomo therapy was conducted for tumor therapy. → The doses of GTV and CTV were compared using DVHs from 3D CRT, IMRT and Tomo therapy. → The GTV was higher when Tomo therapy was used, while the doses of critical organ were low. → They said that Tomo therapy satisfied the goal of radiation therapy more than the others. - Abstract: Evaluation of dose-volume histograms from three-dimensional conformal radiation therapy (3D CRT), intensity-modulated radiation therapy (IMRT), and Tomo therapy was conducted. These three modalities are among the diverse treatment systems available for tumor therapy. Three patients who received tumor therapy for a malignant oligodendroglioma in the cranium, nasopharyngeal carcinoma in the cervical neck, and prostate cancer in the pelvis were selected as study subjects. Therapy plans were made for the three patients before dose-volume histograms were obtained. The doses of the gross tumor volume (GTV) and the clinical target volume (CTV) were compared using the dose-volume histograms obtained from the LINAC-based 3D CRT, IMRT planning station (Varian Eclipse-Varian, version 8.1), and Tomo therapy planning station. In addition, the doses of critical organs in the cranium, cervix, and pelvis that should be protected were compared. The GTV was higher when Tomo therapy was used compared to 3D CRT and the LINAC-based IMRT, while the doses of critical organ tissues that required protection were low. These results demonstrated that Tomo therapy satisfied the ultimate goal of radiation therapy more than the other therapies.

  2. Results of radiation therapy for uterine cervical cancer using high dose rate remote after loading system

    International Nuclear Information System (INIS)

    Ogawa, Yoshihiro; Nemoto, Kenji

    2003-01-01

    In Japan, radiotherapy with high dose rate remote after loading system (HDR-RALS) for intracavitary brachytherapy is the standard treatment for more than 30 years. This report showed the usefulness of HDR-RALS for uterine cervical cancer. From 1980 through 1999, 442 patients with uterine cervical cancers (stage I: 66, stage II: 161, stage III: 165, stage IV: 50) were treated. Radiotherapy was performed both external teletherapy and HDR-RALS. Overall survival rate at 5 years was 60.2%. The 5-year actuarial incidence of all complications was 16.4%. The 5-year actuarial incidence of all complications in cases treated with the sum doses of whole pelvic irradiation (without central shield) and RALS up to 49 Gy, 50 to 59 Gy or larger doses were 7.5%, 11.0% and 25.2%, respectively. Radiation therapy using HDR-RALS was very effective. While the dose of whole pelvic irradiation was increased, the actuarial incidence of all complications was increased. (author)

  3. Estudo de estabilidade do antibiótico meropenem

    OpenAIRE

    Andreas Sebastian Loureiro Mendez

    2007-01-01

    A estabilidade de medicamentos constitui um tema atual e de grande importância no meio científico. Tem sido constantemente abordada em estudos direcionados à avaliação da qualidade das preparações farmacêuticas. O meropenem, um antibiótico carbapenêmico de amplo espectro de ação, é utilizado como um importante recurso terapêutico para o tratamento de infecções graves. Por ser um agente antimicrobiano ativo e eficaz, de uso clínico em muitos países, tornase necessária a pesquisa mais aprofunda...

  4. Enhanced chemiluminescence of the luminol–KMnO4 system by CuO nanosheets and its application for determination of meropenem in water and human serum

    International Nuclear Information System (INIS)

    Khataee, A.R.; Fathinia, M.; Hasanzadeh, A.; Iranifam, M.; Moradkhannejhad, L.

    2014-01-01

    CuO nanosheets were synthesized by an easy and green sonochemical method. It was found that, CuO nanosheets could significantly catalyze the chemiluminescence (CL) reaction of luminol–KMnO 4 in an alkaline condition. Based on this finding, a new CL system (luminol–KMnO 4 –CuO nanosheets) combined with flow injection analysis has been developed for the determination of meropenem for the first time. Moreover, the CL intensity was enhanced when meropenem was presented in the reaction system. Under the optimum conditions, the enhanced CL intensity was proportional to the concentration of meropenem in the ranges of 0.005–6.00 mg L −1 , with a detection limit (3σ) of 0.0036 mg L −1 . The precision of the method was calculated by analyzing samples containing 1.0 mg L −1 meropenem (n=11) and the relative standard deviation (RSD) was 1.7%. Also, a total analysis time per sample was 30 s which confirmed the rapidity of the proposed assay. The practicality of the proposed CL system was evaluated by determining meropenem in spiked environmental water samples and human serum. A discussion on the possible CL reaction mechanism was also presented. - Highlights: • CuO nanosheets (NSs) were successfully prepared by a green sonochemical method. • CuO NSs were found to be an excellent enhancer for luminol−KMnO 4 CL system. • Meropenem was determined using a novel luminol−KMnO 4 −CuO NSs flow injection CL system. • The enhancement mechanism of meropenem on the CL emission was proposed. • Appropriate sensitivity and selectivity were notable features of the proposed method

  5. High-dose thiamine therapy counters dyslipidemia and advanced glycation of plasma protein in streptozotocin-induced diabetic rats.

    Science.gov (United States)

    Karachalias, Nikolaos; Babaei-Jadidi, Roya; Kupich, Christian; Ahmed, Naila; Thornalley, Paul J

    2005-06-01

    The streptozotocin-induced (STZ) diabetic rat experimental model of diabetes on insulin maintenance therapy exhibits dyslipidemia, mild thiamine deficiency, and increased plasma protein advanced glycation end products (AGEs). The reversal of thiamine deficiency by high-dose thiamine and S-benzoylthiamine monophosphate (benfotiamine) prevented the development of incipient nephropathy. Recently, we reported that high-dose thiamine (but not benfotiamine) countered diabetic dyslipidemia. To understand further the differences between the effects of thiamine and benfotiamine therapy, we quantified the levels of the AGEs in plasma protein. We found hydroimidazolone AGE residues derived from glyoxal and methylglyoxal, G-H1 and MG-H1, were increased 115% and 68% in STZ diabetic rats, with respect to normal controls, and were normalized by both thiamine and benfotiamine; whereas N-carboxymethyl-lysine (CML) and N-carboxyethyl-lysine (CEL) residues were increased 74% and 118% in STZ diabetic rats and were normalized by thiamine only. The lack of effect of benfotiamine on plasma CML and CEL residue concentrations suggests there may be important precursors of plasma protein CML and CEL residues other than glyoxal and methylglyoxal. These are probably lipid-derived aldehydes.

  6. Changes in pulmonary function and influencing factors after high-dose intrathoracic radio(chemo)therapy

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Christina [University Clinic Giessen and Marburg, Clinic for Radiotherapy and Radiation Oncology, Marburg (Germany); Ruppiner Kliniken GmbH, Clinic for Radiotherapy and Radiation Oncology, Neuruppin (Germany); Engenhart-Cabillic, Rita; Vorwerk, Hilke [University Clinic Giessen and Marburg, Clinic for Radiotherapy and Radiation Oncology, Marburg (Germany); Schmidt, Michael; Huhnt, Winfried; Blank, Eyck; Sidow, Dietrich; Buchali, Andre [Ruppiner Kliniken GmbH, Clinic for Radiotherapy and Radiation Oncology, Neuruppin (Germany)

    2017-02-15

    Using prospectively collected patient-related, dose-related, and pulmonary function test (PFT) data before radiotherapy (RT) and at several follow-up visits after RT, the time course of PFT changes after high-dose radio(chemo)therapy and influencing factors were analyzed. From April 2012 to October 2015, 81 patients with non-small-cell lung carcinoma (NSCLC), small cell lung carcinoma (SCLC), or esophageal carcinoma where treated with high-dose radio(chemo)therapy. PFT data were collected before treatment and 6 weeks, 12 weeks, and 6 months after RT. The influence of patient- and treatment-related factors on PFT was analyzed. Mean forced expiratory volume in 1 s (FEV1) constantly declined during follow-up (p = 0.001). In total, 68% of patients had a reduced FEV1 at 6 months. Mean vital capacity (VC) didn't change during follow-up (p > 0.05). Mean total lung capacity (TLC) showed a constant decline after RT (p = 0.026). At 6 months, 60% of patients showed a decline in VC and 73% in TLC. The mean diffusion capacity for carbon monoxide (DLCO) declined at 6 and 12 weeks, but recovered slightly at 6 months (p < 0.0005). At 6 months, 86% of patients had a reduced DLCO. After treatment, the partial pressure of CO{sub 2} in the blood (pCO{sub 2}) was increased and pO{sub 2} was decreased (p > 0.05). Only the pretreatment PFT classification had a significant influence on the post-RT FEV1. DLCO seems to be the most reliable indicator for lung tissue damage after thoracic RT. Ventilation parameters appear to be less reliable. Concerning patient- or treatment-related factors, no reliable conclusion can be drawn regarding which factors may be relevant. (orig.) [German] Patientenbezogene, therapiebezogene und Lungenfunktionsdaten (''pulmonary function test'', PFT) wurden vor Radiotherapie (RT) und an verschiedenen Nachsorgeterminen nach RT prospektiv gesammelt, um PFT-Veraenderungen sowie Einflussfaktoren nach Hochdosis-Radio(chemo)therapie zu

  7. Meropenem susceptibility of Neisseria meningitidis and Streptococcus pneumoniae from meningitis patients in The Netherlands

    NARCIS (Netherlands)

    van de Beek, D.; Hensen, E. F.; Spanjaard, L.; de Gans, J.; Enting, R. H.; Dankert, J.

    1997-01-01

    In-vitro susceptibility of 299 Neisseria meningitidis and 157 Streptococcus pneumoniae strains from meningitis patients in The Netherlands in 1993 and 1994 to meropenem was determined using the Etest. Susceptibility to penicillin, ceftriaxone, and chloramphenicol was also determined. Rifampicin

  8. Simultaneous determination and stability studies of linezolid, meropenem and vancomycin in bacterial growth medium by high-performance liquid chromatography.

    Science.gov (United States)

    Wicha, Sebastian G; Kloft, Charlotte

    2016-08-15

    For pharmacokinetic/pharmacodynamic (PK/PD) assessment of antibiotics combinations in in vitro infection models, accurate and precise quantification of drug concentrations in bacterial growth medium is crucial for derivation of valid PK/PD relationships. We aimed to (i) develop a high-performance liquid chromatography (HPLC) assay to simultaneously quantify linezolid (LZD), vancomycin (VAN) and meropenem (MER), as typical components of broad-spectrum antibiotic combination therapy, in bacterial growth medium cation-adjusted Mueller-Hinton broth (CaMHB) and (ii) determine the stability profiles of LZD, VAN and MER under conditions in in vitro infection models. To separate sample matrix components, the final method comprised the pretreatment of 100μL sample with 400μL methanol, the evaporation of supernatant and its reconstitution in water. A low sample volume of 2μL processed sample was injected onto an Accucore C-18 column (2.6μm, 100×2.1mm) coupled to a Dionex Ultimate 3000 HPLC+ system. UV detection at 251, 240 and 302nm allowed quantification limits of 0.5, 2 and 0.5μg/mL for LZD, VAN and MER, respectively. The assay was successfully validated according to the relevant EMA guideline. The rapid method (14min) was successfully applied to quantify significant degradation of LZD, VAN and MER in in vitro infection models: LZD was stable, VAN degraded to 90.6% and MER to 62.9% within 24h compared to t=0 in CaMHB at 37°C, which should be considered when deriving PK/PD relationships in in vitro infection models. Inclusion of further antibiotics into the flexible gradient-based HPLC assay seems promising. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Ion therapy of prostate cancer: daily rectal dose reduction by application of spacer gel

    International Nuclear Information System (INIS)

    Rucinski, Antoni; Brons, Stephan; Richter, Daniel; Habl, Gregor; Debus, Jürgen; Bert, Christoph; Haberer, Thomas; Jäkel, Oliver

    2015-01-01

    Ion beam therapy represents a promising approach to treat prostate cancer, mainly due to its high conformity and radiobiological effectiveness. However, the presence of prostate motion, patient positioning and range uncertainties may deteriorate target dose and increase exposure of organs at risk. Spacer gel injected between prostate and rectum may increase the safety of prostate cancer (PC) radiation therapy by separating the rectum from the target dose field. The dosimetric impact of the application of spacer gel for scanned carbon ion therapy of PC has been analyzed at Heidelberg Ion-Beam Therapy Center (HIT). The robustness of ion therapy treatment plans was investigated by comparison of two data sets of patients treated with and without spacer gel. A research treatment planning system for ion therapy was used for treatment plan optimization and calculation of daily dose distributions on 2 to 9 Computed Tomography (CT) studies available for each of the 19 patients. Planning and daily dose distributions were analyzed with respect to target coverage, maximal dose to the rectum (excluding 1 ml of the greatest dose; Dmax-1 ml) and the rectal volume receiving dose greater than 90% of prescribed target dose (V90 Rectum ), respectively. The application of spacer gel did substantially diminish rectum dose. Dmax-1 ml on the treatment planning CT was on average reduced from 100.0 ± 1.0% to 90.2 ± 4.8%, when spacer gel was applied. The robustness analysis performed with daily CT studies demonstrated for all analyzed patient cases that application of spacer gel results in a decrease of the daily V90 Rectum index, which calculated over all patient cases and CT studies was 10.2 ± 10.4 [ml] and 1.1 ± 2.1 [ml] for patients without and with spacer gel, respectively. The dosimetric benefit of increasing the distance between prostate and rectum using spacer gel for PC treatment with carbon ion beams has been quantified. Application of spacer gel substantially reduced rectal

  10. Neutrons in active proton therapy. Parameterization of dose and dose equivalent

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Uwe; Haelg, Roger A. [Univ. of Zurich (Switzerland). Dept. of Physics; Radiotherapy Hirslanden AG, Aarau (Switzerland); Lomax, Tony [Paul Scherrer Institute, Villigen (Switzerland). Center for Proton Therapy

    2017-08-01

    One of the essential elements of an epidemiological study to decide if proton therapy may be associated with increased or decreased subsequent malignancies compared to photon therapy is an ability to estimate all doses to non-target tissues, including neutron dose. This work therefore aims to predict for patients using proton pencil beam scanning the spatially localized neutron doses and dose equivalents. The proton pencil beam of Gantry 1 at the Paul Scherrer Institute (PSI) was Monte Carlo simulated using GEANT. Based on the simulated neutron dose and neutron spectra an analytical mechanistic dose model was developed. The pencil beam algorithm used for treatment planning at PSI has been extended using the developed model in order to calculate the neutron component of the delivered dose distribution for each treated patient. The neutron dose was estimated for two patient example cases. The analytical neutron dose model represents the three-dimensional Monte Carlo simulated dose distribution up to 85 cm from the proton pencil beam with a satisfying precision. The root mean square error between Monte Carlo simulation and model is largest for 138 MeV protons and is 19% and 20% for dose and dose equivalent, respectively. The model was successfully integrated into the PSI treatment planning system. In average the neutron dose is increased by 10% or 65% when using 160 MeV or 177 MeV instead of 138 MeV. For the neutron dose equivalent the increase is 8% and 57%. The presented neutron dose calculations allow for estimates of dose that can be used in subsequent epidemiological studies or, should the need arise, to estimate the neutron dose at any point where a subsequent secondary tumour may occur. It was found that the neutron dose to the patient is heavily increased with proton energy.

  11. The Effect of Different Carbapenem Antibiotics (Ertapenem, Imipenem/Cilastatin, and Meropenem) on Serum Valproic Acid Concentrations.

    Science.gov (United States)

    Wu, Chien-Chih; Pai, Tsung-Yu; Hsiao, Fei-Yuan; Shen, Li-Jiuan; Wu, Fe-Lin Lin

    2016-10-01

    Carbapenem antibiotics (CBPMs) may significantly reduce the serum concentration of valproic acid (VPA), but the extent of this effect among various CBPMs is unknown. This study compared the extent and onset of the interactions among ertapenem, imipenem/cilastatin, and meropenem. A 5-year retrospective study was performed. Hospitalized patients over 18 years old who received VPA and a CBPM concurrently were enrolled via the pharmacy computer system. Patients who lacked VPA serum concentration measurements before or during CBPMs' use, had concurrent medication(s) that might interfere with VPA metabolism, or had a history of liver cirrhosis were excluded. Total VPA serum concentrations before and during CBPMs' use and after its discontinuation were recorded, and differences among various CBPMs were analyzed. Fifty-two patients were included in this analysis. Irrespective of the route of administration, VPA serum concentrations were subtherapeutic in 90% of the subjects during CBPMs' use. There was a significant decrease (P imipenem/cilastatin (N = 17), and meropenem (N = 26) groups, respectively. The effect of ertapenem and meropenem on VPA was significantly more expressed than that of imipenem/cilastatin (P imipenem/cilastatin. Because of the dramatic reduction of VPA serum concentration during CBPMs' use, concomitant use of VPA and CBPMs should be avoided.

  12. The Comparison of Two Types of Treatment (High Dose and Low Dose IVIG in Children with GBS in Mofid Hospital

    Directory of Open Access Journals (Sweden)

    Parvaneh Karim-Zadeh

    2003-12-01

    Full Text Available Objective: Acute inflammatory demyelinating peripheral neuropathy (Guillain-Barre-Syndrome is by far the most common cause of immune–mediated peripheral nerve disease in children and with the near disappearance of poliomyelitis, is responsible for the great majority of cases of acute flaccid paralysis. Several controlled studies have done with corticosteroids, plasma pheresis and IVIG in pediatric patients. IVIG treatment can be done in two types of treatment: 1- High dose that means 1gr/kg/day for 2 days. 2- Low dose that means 400mg/kg/day for 5 days. Several studies in other countries have shown faster rate of recovery in patients who received total dose of IVIG in 2 days as opposed to 5 days. Materials & Methods: Because we have not any study about this two types of treatment in IRAN we decided to comparison this two types of IVIG treatment. So the patients that referred to Mofid children hospital for weakness and we diagnosed GBS (with history, physical examination, laboratories and EMG-NCV are divided in two groups: 1- High dose IVIG treatment (experimental group. 2- Low dose IVIG treatment (control group Then the results evaluated. Results: Our findings included that in high dose IVIG therapy we have faster rate of recovery and the Hospital stay is shorter than low dose IVIG-therapy. Also in this type of treatment “because the patients cure faster” , so complications are decreased in them. In the group of high dose IVIG therapy, lower and upper extremities weakness decreased in time. Conclusion: We did not receive any relationship between side effects of drugs and the type of treatment. The relationship between high dose IVIG therapy and drug side effects was not significant.

  13. High-Dose Estradiol-Replacement Therapy Enhances the Renal Vascular Response to Angiotensin II via an AT2-Receptor Dependent Mechanism

    Directory of Open Access Journals (Sweden)

    Tahereh Safari

    2015-01-01

    Full Text Available Physiological levels of estrogen appear to enhance angiotensin type 2 receptor- (AT2R- mediated vasodilatation. However, the effects of supraphysiological levels of estrogen, analogous to those achieved with high-dose estrogen replacement therapy in postmenopausal women, remain unknown. Therefore, we pretreated ovariectomized rats with a relatively high dose of estrogen (0.5 mg/kg/week for two weeks. Subsequently, renal hemodynamic responses to intravenous angiotensin II (Ang II, 30–300 ng/kg/min were tested under anesthesia, while renal perfusion pressure was held constant. The role of AT2R was examined by pretreating groups of rats with PD123319 or its vehicle. Renal blood flow (RBF decreased in a dose-related manner in response to Ang II. Responses to Ang II were enhanced by pretreatment with estradiol. For example, at 300 ng kg−1 min−1, Ang II reduced RBF by 45.7±1.9% in estradiol-treated rats but only by 27.3±5.1% in vehicle-treated rats. Pretreatment with PD123319 blunted the response of RBF to Ang II in estradiol-treated rats, so that reductions in RBF were similar to those in rats not treated with estradiol. We conclude that supraphysiological levels of estrogen promote AT2R-mediated renal vasoconstriction. This mechanism could potentially contribute to the increased risk of cardiovascular disease associated with hormone replacement therapy using high-dose estrogen.

  14. Radiation Dose-Response Model for Locally Advanced Rectal Cancer After Preoperative Chemoradiation Therapy

    DEFF Research Database (Denmark)

    Appelt, A. L.; Ploen, J.; Vogelius, I. R.

    2013-01-01

    estimated radiation dose-response curves for various grades of tumor regression after preoperative CRT. Methods and Materials: A total of 222 patients, treated with consistent chemotherapy and radiation therapy techniques, were considered for the analysis. Radiation therapy consisted of a combination...... of external-beam radiation therapy and brachytherapy. Response at the time of operation was evaluated from the histopathologic specimen and graded on a 5-point scale (TRG1-5). The probability of achieving complete, major, and partial response was analyzed by ordinal logistic regression, and the effect...... of including clinical parameters in the model was examined. The radiation dose-response relationship for a specific grade of histopathologic tumor regression was parameterized in terms of the dose required for 50% response, D-50,D-i, and the normalized dose-response gradient, gamma(50,i). Results: A highly...

  15. Hypofractionated High-Dose Proton Beam Therapy for Stage I Non-Small-Cell Lung Cancer: Preliminary Results of A Phase I/II Clinical Study

    International Nuclear Information System (INIS)

    Hata, Masaharu; Tokuuye, Koichi; Kagei, Kenji; Sugahara, Shinji; Nakayama, Hidetsugu; Fukumitsu, Nobuyoshi; Hashimoto, Takayuki; Mizumoto, Masashi; Ohara, Kiyoshi; Akine, Yasuyuki

    2007-01-01

    Purpose: To present treatment outcomes of hypofractionated high-dose proton beam therapy for Stage I non-small-cell lung cancer (NSCLC). Methods and Materials: Twenty-one patients with Stage I NSCLC (11 with Stage IA and 10 with Stage IB) underwent hypofractionated high-dose proton beam therapy. At the time of irradiation, patient age ranged from 51 to 85 years (median, 74 years). Nine patients were medically inoperable because of comorbidities, and 12 patients refused surgical resection. Histology was squamous cell carcinoma in 6 patients, adenocarcinoma in 14, and large cell carcinoma in 1. Tumor size ranged from 10 to 42 mm (median, 25 mm) in maximum diameter. Three and 18 patients received proton beam irradiation with total doses of 50 Gy and 60 Gy in 10 fractions, respectively, to primary tumor sites. Results: Of 21 patients, 2 died of cancer and 2 died of pneumonia at a median follow-up period of 25 months. The 2-year overall and cause-specific survival rates were 74% and 86%, respectively. All but one of the irradiated tumors were controlled during the follow-up period. Five patients showed recurrences 6-29 months after treatment, including local progression and new lung lesions outside of the irradiated volume in 1 and 4 patients, respectively. The local progression-free and disease-free rates were 95% and 79% at 2 years, respectively. No therapy-related toxicity of Grade ≥3 was observed. Conclusions: Hypofractionated high-dose proton beam therapy seems feasible and effective for Stage I NSCLC. Proton beams may contribute to enhanced efficacy and lower toxicity in the treatment of patients with Stage I NSCLC

  16. Fosfomycin versus meropenem in bacteraemic urinary tract infections caused by extended-spectrum β-lactamase-producing Escherichia coli (FOREST): study protocol for an investigator-driven randomised controlled trial.

    Science.gov (United States)

    Rosso-Fernández, Clara; Sojo-Dorado, Jesús; Barriga, Angel; Lavín-Alconero, Lucía; Palacios, Zaira; López-Hernández, Inmaculada; Merino, Vicente; Camean, Manuel; Pascual, Alvaro; Rodríguez-Baño, Jesús

    2015-03-31

    Finding therapeutic alternatives to carbapenems in infections caused by extended-spectrum β-lactamase-producing Escherichia coli (ESBL-EC) is imperative. Although fosfomycin was discovered more than 40 years ago, it was not investigated in accordance with current standards and so is not used in clinical practice except in desperate situations. It is one of the so-called neglected antibiotics of high potential interest for the future. The main objective of this project is to demonstrate the clinical non-inferiority of intravenous fosfomycin with regard to meropenem for treating bacteraemic urinary tract infections (UTI) caused by ESBL-EC. This is a 'real practice' multicentre, open-label, phase III randomised controlled trial, designed to compare the clinical and microbiological efficacy, and safety of intravenous fosfomycin (4 g/6 h) and meropenem (1 g/8 h) as targeted therapy for this infection; a change to oral therapy is permitted after 5 days in both arms, in accordance with predetermined options. The study design follows the latest recommendations for designing trials investigating new options for multidrug-resistant bacteria. Secondary objectives include the study of fosfomycin concentrations in plasma and the impact of both drugs on intestinal colonisation by multidrug-resistant Gram-negative bacilli. Ethical approval was obtained from the Andalusian Coordinating Institutional Review Board (IRB) for Biomedical Research (Referral Ethics Committee), which obtained approval from the local ethics committees at all participating sites in Spain (22 sites). Data will be presented at international conferences and published in peer-reviewed journals. This project is proposed as an initial step in the investigation of an orphan antimicrobial of low cost with high potential as a therapeutic alternative in common infections such as UTI in selected patients. These results may have a major impact on the use of antibiotics and the development of new projects

  17. High-dose methylprednisolone pulse therapy for treatment of refractory intestinal involvement caused by Henoch-Schönlein purpura: a case report.

    Science.gov (United States)

    Kang, Hyun Sik; Chung, Hee Sup; Kang, Ki-Soo; Han, Kyoung Hee

    2015-03-24

    Henoch-Schönlein purpura is an immunoglobulin A-mediated, small vascular inflammatory disease that can be associated with palpable purpura, arthralgia, abdominal pain, or nephritis. The presence of purpura facilitates the diagnosis of Henoch-Schönlein purpura at the onset of associated symptoms, whereas the absence of purpura makes the diagnosis challenging. It is important to diagnose Henoch-Schönlein purpura with delayed-onset skin purpura to avoid unnecessary surgery for acute abdomen. Most cases of Henoch-Schönlein purpura with severe abdominal pain are treated with low-dose steroids and intravenous immunoglobulin. A 15-year-old Korean girl complained of severe abdominal pain and delayed-onset purpura on admission. Henoch-Schönlein purpura was diagnosed based on endoscopic findings of hemorrhagic duodenitis and duodenal vasculitis and abdominal computed tomography findings of edematous bowels. Two common initial treatments, a low-dose steroid and intravenous immunoglobulin, were administered, but there was no improvement for 1 month. Subsequently, we used high-dose intravenous methylprednisolone pulse therapy (30 mg/kg/day, with a maximum of 1g/day), which dramatically alleviated her abdominal symptoms. High-dose intravenous methylprednisolone pulse therapy can be used as the ultimate treatment for delayed-onset Henoch-Schönlein purpura with severe abdominal pain when symptoms do not improve after low-dose steroid and intravenous immunoglobulin treatments.

  18. Maximally effective dosing regimens of meropenem in patients with septic shock

    DEFF Research Database (Denmark)

    Sjövall, Fredrik; Alobaid, Abdulaziz S; Wallis, Steven C

    2018-01-01

    was required for both empirical and targeted treatment. In patients with a CL CR of ≤ 100 mL/min, successful concentration targets could be reached with intermittent dosing of 1000 mg/8 h. Conclusions: In patients with septic shock and possible augmented renal clearance, doses should be increased and...

  19. Single dose planning for radioiodine-131 therapy of Graves' disease

    International Nuclear Information System (INIS)

    Kita, Tamotsu; Yokoyama, Kunihiko; Kinuya, Seigo; Taki, Junichi; Michigishi, Takatoshi; Tonami, Norihisa

    2004-01-01

    Patients with Graves' disease were studied one year after radioiodine-131 therapy to assess the relationship between the effectiveness of the therapy and the radioiodine doses used. Patients were classified into three groups according to thyroid function as hyperthyroidism, euthyroidism and hypothyroidism at one year after I-131 therapy. In these groups we compared the mean values of dose, dose per thyroid weight calculated with I-123 uptake before the therapy (pre D/W), dose per thyroid weight calculated with therapeutic I-131 uptake (post D/W), and absorbed dose. No significant differences were found between the three groups in terms of dose or pre D/W. The mean values of post D/W and absorbed dose in the non-hyperthyroid (euthyroid and hypothyroid) group were significantly greater than those in the hyperthyroid group. Post D/W of 6.3 MBq/g was a threshold separating the non-hyperthyroid group from the hyperthyroid group. There was no correlation between pre D/W and post D/W; however, the mean post D/W was significantly greater than the mean pre D/W. All patients with pre D/W above 6.3 MBq/g showed non-hyperthyroidism at one year after the radioiodine treatment. No indicators before the radioiodine therapy had significant relationships with the effectiveness of the therapy at one year after the treatment. However, the single therapy planned for setting the pre D/W above 6.3 MBq/g will certainly make the patients non-hyperthyroid. As this proposal of dose planning is based on a small number of patients, further study is needed. (author)

  20. Three Dimensional Checkerboard Synergy Analysis of Colistin, Meropenem, Tigecycline against Multidrug-Resistant Clinical Klebsiella pneumonia Isolates.

    Directory of Open Access Journals (Sweden)

    Claudia Stein

    Full Text Available The spread of carbapenem-non-susceptible Klebsiella pneumoniae strains bearing different resistance determinants is a rising problem worldwide. Especially infections with KPC (Klebsiella pneumoniae carbapenemase - producers are associated with high mortality rates due to limited treatment options. Recent clinical studies of KPC-blood stream infections revealed that colistin-based combination therapy with a carbapenem and/or tigecycline was associated with significantly decreased mortality rates when compared to colistin monotherapy. However, it remains unclear if these observations can be transferred to K. pneumoniae harboring other mechanisms of carbapenem resistance. A three-dimensional synergy analysis was performed to evaluate the benefits of a triple combination with meropenem, tigecycline and colistin against 20 K. pneumoniae isolates harboring different β-lactamases. To examine the mechanism behind the clinically observed synergistic effect, efflux properties and outer membrane porin (Omp genes (ompK35 and ompK36 were also analyzed. Synergism was found for colistin-based double combinations for strains exhibiting high minimal inhibition concentrations against all of the three antibiotics. Adding a third antibiotic did not result in further increased synergistic effect in these strains. Antagonism did not occur. These results support the idea that colistin-based double combinations might be sufficient and the most effective combination partner for colistin should be chosen according to its MIC.

  1. Some thoughts on tolerance, dose, and fractionation in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gahbauer, R.; Goodman, J.; Blue, T.

    1988-01-01

    Unique to boron neutron capture therapy, the tolerance very strongly depends on the boron concentration in normal brain, skin and blood. If one first considers the ideal situation of a 2 KeV beam and a compound clearing from normal tissues and blood, the tolerance dose to epithermal beams relates to the maximum tolerated capture gamma dose and capture high LET dose, H (n,gamma)D and N(n,p) 14 C. The authors can relate this gamma and high LET dose to known clinical experience. Assuming gamma and high LET dose ratios as given by Fairchild and Bond, one may first choose a clearly safe high LET whole brain dose and calculate the unavoidably resulting gamma dose. To a first approximation 500 cGy of high LET dose results in 3,000 cGy gamma dose. One can speculate that this approximates the tolerance of whole brain to the 2 KeV beam with no contributing boron dose if the radiation is fractionated. It would clearly be beyond tolerance in a single fraction where most therapists would be uncomfortable to deliver even one third of the above doses

  2. High-dose-rate intraoperative radiation therapy: the nuts and bolts of starting a program

    Science.gov (United States)

    Moningi, Shalini; Armour, Elwood P.; Terezakis, Stephanie A.; Efron, Jonathan E.; Gearhart, Susan L.; Bivalacqua, Trinity J.; Kumar, Rachit; Le, Yi; Kien Ng, Sook; Wolfgang, Christopher L.; Zellars, Richard C.; Ellsworth, Susannah G.; Ahuja, Nita

    2014-01-01

    High-dose-rate intraoperative radiation therapy (HDR-IORT) has historically provided effective local control (LC) for patients with unresectable and recurrent tumors. However, IORT is limited to only a few specialized institutions and it can be difficult to initiate an HDR-IORT program. Herein, we provide a brief overview on how to initiate and implement an HDR-IORT program for a selected group of patients with gastrointestinal and pelvic solid tumors using a multidisciplinary approach. Proper administration of HDR-IORT requires institutional support and a joint effort among physics staff, oncologists, surgeons, anesthesiologists, and nurses. In order to determine the true efficacy of IORT for various malignancies, collaboration among institutions with established IORT programs is needed. PMID:24790628

  3. Prevention of incipient diabetic nephropathy by high-dose thiamine and benfotiamine.

    Science.gov (United States)

    Babaei-Jadidi, Roya; Karachalias, Nikolaos; Ahmed, Naila; Battah, Sinan; Thornalley, Paul J

    2003-08-01

    Accumulation of triosephosphates arising from high cytosolic glucose concentrations in hyperglycemia is the trigger for biochemical dysfunction leading to the development of diabetic nephropathy-a common complication of diabetes associated with a high risk of cardiovascular disease and mortality. Here we report that stimulation of the reductive pentosephosphate pathway by high-dose therapy with thiamine and the thiamine monophosphate derivative benfotiamine countered the accumulation of triosephosphates in experimental diabetes and inhibited the development of incipient nephropathy. High-dose thiamine and benfotiamine therapy increased transketolase expression in renal glomeruli, increased the conversion of triosephosphates to ribose-5-phosphate, and strongly inhibited the development of microalbuminuria. This was associated with decreased activation of protein kinase C and decreased protein glycation and oxidative stress-three major pathways of biochemical dysfunction in hyperglycemia. Benfotiamine also inhibited diabetes-induced hyperfiltration. This was achieved without change in elevated plasma glucose concentration and glycated hemoglobin in the diabetic state. High-dose thiamine and benfotiamine therapy is a potential novel strategy for the prevention of clinical diabetic nephropathy.

  4. Effects of moderate-dose versus high-dose trimethoprim on serum creatinine and creatinine clearance and adverse reactions.

    OpenAIRE

    Naderer, O; Nafziger, A N; Bertino, J S

    1997-01-01

    The effects of a 10-day course of moderate-dose (10 mg/kg/day) or high-dose (20 mg/kg/day) trimethoprim therapy on serum creatinine, measured creatinine clearance, urinary creatinine excretion, and serum folate were studied in 20 healthy volunteers. Serum creatinine concentrations increased significantly during trimethoprim therapy, began to decrease near day 10, and returned to baseline during the washout phase at both dosage levels. At the same time, measured creatinine clearance and urine ...

  5. COMPARISON OF THE PERIPHERAL DOSES FROM DIFFERENT IMRT TECHNIQUES FOR PEDIATRIC HEAD AND NECK RADIATION THERAPY.

    Science.gov (United States)

    Toyota, Masahiko; Saigo, Yasumasa; Higuchi, Kenta; Fujimura, Takuya; Koriyama, Chihaya; Yoshiura, Takashi; Akiba, Suminori

    2017-11-01

    Intensity-modulated radiation therapy (IMRT) can deliver high and homogeneous doses to the target area while limiting doses to organs at risk. We used a pediatric phantom to simulate the treatment of a head and neck tumor in a child. The peripheral doses were examined for three different IMRT techniques [dynamic multileaf collimator (DMLC), segmental multileaf collimator (SMLC) and volumetric modulated arc therapy (VMAT)]. Peripheral doses were evaluated taking thyroid, breast, ovary and testis as the points of interest. Doses were determined using a radio-photoluminescence glass dosemeter, and the COMPASS system was used for three-dimensional dose evaluation. VMAT achieved the lowest peripheral doses because it had the highest monitor unit efficiency. However, doses in the vicinity of the irradiated field, i.e. the thyroid, could be relatively high, depending on the VMAT collimator angle. DMLC and SMLC had a large area of relatively high peripheral doses in the breast region. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. An international intercomparison of absorbed dose measurements for radiation therapy

    International Nuclear Information System (INIS)

    Taiman Kadni; Noriah Mod Ali

    2002-01-01

    Dose intercomparison on an international basis has become an important component of quality assurance measurement i.e. to check the performance of absorbed dose measurements in radiation therapy. The absorbed dose to water measurements for radiation therapy at the SSDL, MINT have been regularly compared through international intercomparison programmes organised by the IAEA Dosimetry Laboratory, Seibersdorf, Austria such as IAEA/WHO TLD postal dose quality audits and the Intercomparison of therapy level ionisation chamber calibration factors in terms of air kerma and absorbed dose to water calibration factors. The results of these intercomparison in terms of percentage deviations for Cobalt 60 gamma radiation and megavoltage x-ray from medical linear accelerators participated by the SSDL-MINT during the year 1985-2001 are within the acceptance limit. (Author)

  7. Simultaneous adjuvant radiation therapy and chemotherapy in high-risk breast cancer--toxicity and dose modification: a trans-tasman radiation oncology group multi-institution study

    International Nuclear Information System (INIS)

    Denham, James W.; Hamilton, Christopher S.; Christie, David; O'Brien, Maree; Bonaventura, Antonino; Stewart, John F.; Ackland, Stephen P.; Lamb, David S.; Spry, Nigel A.; Dady, Peter; Atkinson, Christopher H.; Wynne, Christopher; Joseph, David J.

    1995-01-01

    Purpose: To establish the toxicity profile of simultaneously administered postoperative radiation therapy and CMF chemotherapy as a prelude to a randomized controlled study addressing the sequencing of the two modalities. Methods and Materials: One hundred and thirty eight breast cancer patients at high risk of locoregional, as well as systemic relapse, who were referred to three centers in Australia and New Zealand were treated with postoperative radiation therapy and chemotherapy simultaneously. Acute toxicity and dose modifications in these patients were compared with 83 patients treated over the same time frame with chemotherapy alone. In a separate study the long-term radiation and surgical effects in 24 patients treated simultaneously with radiation therapy and chemotherapy at Newcastle (Australia) following conservative surgery were compared with 23 matched patients treated at Newcastle with radiation therapy alone. Results: Myelotoxicity was increased in patients treated simultaneously with radiation therapy and chemotherapy. The effect was not great, but may have contributed to chemotherapy dose reductions. Lymphopenia was observed to be the largest factor in total white cell depressions caused by the simultaneous administration of radiation therapy. Postsurgical appearances were found to so dominate long-term treatment effects on the treated breast that the effect of radiation therapy dose and additional chemotherapy was difficult to detect. Conclusion: Studies addressing the sequencing of radiation therapy and chemotherapy will necessarily be large because adverse effects from administering the two modalities simultaneously are not great. The present study has endorsed the importance in future studies of stratification according to the extent and type of surgery and adherence to a single strict policy of chemotherapy dose modification

  8. Appropriateness of antibiotic prescription for targeted therapy of infections caused by multidrug-resistant bacteria: assessment of the most common improper uses in a tertiary hospital in southern Italy.

    Science.gov (United States)

    Viceconte, Giulio; Maraolo, Alberto Enrico; Iula, Vita Dora; Catania, Maria Rosaria; Tosone, Grazia; Orlando, Raffaele

    2017-09-01

    A huge proportion of antibiotic therapies for infections caused by multidrug-resistant bacteria (MDR) are inappropriate. In this study, we described the most common causes of inappropriateness of definitive antibiotic regimes in a large university hospital in southern Italy and we evaluated the impact on microbial eradication, length of stay, 30-day readmission and mortality. We retrospectively assessed 45 patients who received a definitive antibiotic therapy after isolation of multidrug-resistant Staphylococcus aureus, Enterococcus spp., Enterobacteriaceae, Pseudomonas aeruginosa and Acinetobacter spp. strains between 2014 and 2015. From the literature, we set a series of criteria to retrospectively determine the appropriateness of the therapy. In all, 61% of the prescribed antibiotic regimes were found to be inappropriate, especially due to incorrect drug dosage. It emerged that meropenem was the antibiotic most frequently inappropriately used. In 46% of infections caused by MDR but not extended-spectrum β-lactamase-producing Enterobacteriaceae, carbapenems were inappropriately administered. Microbial eradication was achieved in 87% of the appropriate therapy group compared to 31% of the inappropriate therapy group (chi-square=6.750, p<0.027). No statistically significant association was found between inappropriate therapy and the length of stay (chi-square=3.084, p=0.101) and 30-day readmission (p=0.103). Definitive antibiotic therapy in infections caused by multidrug-resistant bacteria in a large university hospital is often inappropriate, especially due to the drug dosing regimen, particularly in the case of meropenem and colistin. This inappropriateness has a significant impact on post-treatment microbial eradication in specimens collected after antibiotic therapy.

  9. Low dose rate and high dose rate intracavitary treatment for cervical cancer

    International Nuclear Information System (INIS)

    Hareyama, Masato; Oouchi, Atsushi; Shidou, Mitsuo

    1997-01-01

    From 1984 through 1993, 144 previous untreated patients with carcinoma of uterine cervix were treated with either low dose rate 137 Cs therapy (LDR) or high dose rate 60 Co therapy (HDR). The local failure rates for more than 2-years for the primary lesions were 11.8% (8 of 63 patients) for LDR and 18.0% (11 of 61 patients). Rectal complication rates were significantly lower for HDR versus LDR (14.3% VS. 32.8%. p<0.01). Also, bladder complication rates were significantly lower for HDR versus LDR (0% VS. 10.4%, p<0.005). Treatment results in term of local control were equivalent for HDR and LDR treatment. However, the incidence of complications was higher for the LDR group than for the HDR group. (author)

  10. Low-dose radiation potentiates the therapeutic efficacy of folate receptor-targeted hapten therapy.

    Science.gov (United States)

    Sega, Emanuela I; Lu, Yingjuan; Ringor, Michael; Leamon, Christopher P; Low, Philip S

    2008-06-01

    Human cancers frequently overexpress a high-affinity cell-surface receptor for the vitamin folic acid. Highly immunogenic haptens can be targeted to folate receptor-expressing cell surfaces by administration of folate-hapten conjugates, rendering the decorated tumor cell surfaces more recognizable by the immune system. Treatment of antihapten-immunized mice with folate-hapten constructs results in elimination of moderately sized tumors by the immune system. However, when subcutaneous tumors exceed 300 mm(3) before initiation of therapy, antitumor activity is significantly decreased. In an effort to enhance the efficacy of folate-targeted hapten immunotherapy (FTHI) against large tumors, we explored the combination of targeted hapten immunotherapy with low-dose radiotherapy. Mice bearing 300-mm(3) subcutaneous tumors were treated concurrently with FTHI (500 nmol/kg of folate conjugated to fluorescein isothiocyanate, 20,000 U/dose of interleukin 2, and 25,000 U/dose of interferon alpha) and low-dose radiotherapy (3 Gy/dose focused directly on the desired tumor mass). The efficacy of therapy was evaluated by measuring tumor volume. Tumor growth analyses show that radiotherapy synergizes with FTHI in antihapten-immunized mice, thereby allowing for cures of animals bearing tumors greater than 300 mm(3). More importantly, nonirradiated distal tumor masses in animals containing locally irradiated tumors also showed improved response to hapten immunotherapy, suggesting that not all tumor lesions must be identified and irradiated to benefit from the combination therapy. These results suggest that simultaneous treatment with FTHI and radiation therapy can enhance systemic antitumor activity in tumor-bearing mice.

  11. Low-Dose Radiation Potentiates the Therapeutic Efficacy of Folate Receptor-Targeted Hapten Therapy

    International Nuclear Information System (INIS)

    Sega, Emanuela I.; Lu Yingjuan; Ringor, Michael; Leamon, Christopher P.; Low, Philip S.

    2008-01-01

    Purpose: Human cancers frequently overexpress a high-affinity cell-surface receptor for the vitamin folic acid. Highly immunogenic haptens can be targeted to folate receptor-expressing cell surfaces by administration of folate-hapten conjugates, rendering the decorated tumor cell surfaces more recognizable by the immune system. Treatment of antihapten-immunized mice with folate-hapten constructs results in elimination of moderately sized tumors by the immune system. However, when subcutaneous tumors exceed 300 mm 3 before initiation of therapy, antitumor activity is significantly decreased. In an effort to enhance the efficacy of folate-targeted hapten immunotherapy (FTHI) against large tumors, we explored the combination of targeted hapten immunotherapy with low-dose radiotherapy. Methods and Materials: Mice bearing 300-mm 3 subcutaneous tumors were treated concurrently with FTHI (500 nmol/kg of folate conjugated to fluorescein isothiocyanate, 20,000 U/dose of interleukin 2, and 25,000 U/dose of interferon α) and low-dose radiotherapy (3 Gy/dose focused directly on the desired tumor mass). The efficacy of therapy was evaluated by measuring tumor volume. Results: Tumor growth analyses show that radiotherapy synergizes with FTHI in antihapten-immunized mice, thereby allowing for cures of animals bearing tumors greater than 300 mm 3 . More importantly, nonirradiated distal tumor masses in animals containing locally irradiated tumors also showed improved response to hapten immunotherapy, suggesting that not all tumor lesions must be identified and irradiated to benefit from the combination therapy. Conclusions: These results suggest that simultaneous treatment with FTHI and radiation therapy can enhance systemic antitumor activity in tumor-bearing mice

  12. Phenotypic detection of the cfiA metallo-β-lactamase in Bacteroides fragilis with the meropenem-EDTA double-ended Etest and the ROSCO KPC/MBL Confirm Kit

    DEFF Research Database (Denmark)

    Ferløv-Schwensen, Simon Andreas; Acar, Ziyap; Sydenham, Thomas V

    2017-01-01

    OBJECTIVES: To investigate the performance of the meropenem and imipenem double-ended Etest ± EDTA and the tablet-based (meropenem and meropenem + dipicolinic acid) KPC/MBL Confirm Kit to detect cfiA metallo-β-lactamase (MBL) in Bacteroides fragilis. METHODS: Well-characterized B. fragilis isolates...

  13. Safety and tolerability of high doses of glucocorticoides

    Directory of Open Access Journals (Sweden)

    Rakić Branislava D.

    2016-01-01

    Full Text Available Introduction: Treatment of acute lymphoblastic leukemia includes the use of high doses of glucocorticoides (prednisone and dexamethasone, which significantly increase the success of therapy due to lymphocytolitic effect. The aim: The aim of the study was to determine tolerability of high doses of prednisone and dexamethasone in children with acute lymphoblastic leukemia and the structure and the intensity of adverse effects, occurred after application of these medicines. Subjects and methods: In a prospective study, we analyzed adverse effects of high doses of glucocorticoides in children suffering acute lymphoblastic leukemia treated in the Institute for Child and Youth Health Care of Vojvodina, since December 2010. until October 2014, were analyzed. This study included 18 patients, aged from 2 to 15 years. Results: Hyperglycemia appeared in 89% of patients treated with prednisone and in 61% of patients treated with dexamethasone. In order to control the high blood glucose level (above 10 mmol /L, in 11% of patients insulin was used. Hypertension appeared in 28% patients treated with prednisone and dexamethasone. Antihypertensives were needed for regulation in 17% patients. Hypopotassemia and hypocalcaemia were significantly more expressed after the use of prednisone in comparison to dexamethasone. In 11% of patients, the treatment with dexamethasone caused depressive behavior, followed by agitation. Conclusion: Adverse effects of dexamethasone and prednisone, administered in high doses in children with ALL were known, expected and reversible. Adverse reactions usually disappeared spontaneously or after short-term symptomatic therapy.

  14. 18F-Choline Positron Emission Tomography/Computed Tomography–Driven High-Dose Salvage Radiation Therapy in Patients With Biochemical Progression After Radical Prostatectomy: Feasibility Study in 60 Patients

    International Nuclear Information System (INIS)

    D'Angelillo, Rolando M.; Sciuto, Rosa; Ramella, Sara; Papalia, Rocco; Jereczek-Fossa, Barbara A.; Trodella, Luca E.; Fiore, Michele; Gallucci, Michele; Maini, Carlo L.; Trodella, Lucio

    2014-01-01

    Purpose: To retrospectively review data of a cohort of patients with biochemical progression after radical prostatectomy, treated according to a uniform institutional treatment policy, to evaluate toxicity and feasibility of high-dose salvage radiation therapy (80 Gy). Methods and Materials: Data on 60 patients with biochemical progression after radical prostatectomy between January 2009 and September 2011 were reviewed. The median value of prostate-specific antigen before radiation therapy was 0.9 ng/mL. All patients at time of diagnosis of biochemical recurrence underwent dynamic 18 F-choline positron emission tomography/computed tomography (PET/CT), which revealed in all cases a local recurrence. High-dose salvage radiation therapy was delivered up to total dose of 80 Gy to 18F-choline PET/CT-positive area. Toxicity was recorded according to the Common Terminology Criteria for Adverse Events, version 3.0, scale. Results: Treatment was generally well tolerated: 54 patients (90%) completed salvage radiation therapy without any interruption. Gastrointestinal grade ≥2 acute toxicity was recorded in 6 patients (10%), whereas no patient experienced a grade ≥2 genitourinary toxicity. No grade 4 acute toxicity events were recorded. Only 1 patient (1.7%) experienced a grade 2 gastrointestinal late toxicity. With a mean follow-up of 31.2 months, 46 of 60 patients (76.6%) were free of recurrence. The 3-year biochemical progression-free survival rate was 72.5%. Conclusions: At early follow-up, 18 F-choline PET/CT-driven high-dose salvage radiation therapy seems to be feasible and well tolerated, with a low rate of toxicity

  15. An improved Monte Carlo (MC) dose simulation for charged particle cancer therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ying, C. K. [Advanced Medical and Dental Institute, AMDI, Universiti Sains Malaysia, Penang, Malaysia and School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu (Malaysia); Kamil, W. A. [Advanced Medical and Dental Institute, AMDI, Universiti Sains Malaysia, Penang, Malaysia and Radiology Department, Hospital USM, Kota Bharu (Malaysia); Shuaib, I. L. [Advanced Medical and Dental Institute, AMDI, Universiti Sains Malaysia, Penang (Malaysia); Matsufuji, Naruhiro [Research Centre of Charged Particle Therapy, National Institute of Radiological Sciences, NIRS, Chiba (Japan)

    2014-02-12

    Heavy-particle therapy such as carbon ion therapy are more popular nowadays because of the nature characteristics of charged particle and almost no side effect to patients. An effective treatment is achieved with high precision of dose calculation, in this research work, Geant4 based Monte Carlo simulation method has been used to calculate the radiation transport and dose distribution. The simulation have the same setting with the treatment room in Heavy Ion Medical Accelerator, HIMAC. The carbon ion beam at the isocentric gantry nozzle for the therapeutic energy of 290 MeV/u was simulated, experimental work was carried out in National Institute of Radiological Sciences, NIRS, Chiba, Japan by using the HIMAC to confirm the accuracy and qualities dose distribution by MC methods. The Geant4 based simulated dose distribution were verified with measurements for Bragg peak and spread out Bragg peak (SOBP) respectively. The verification of results shows that the Bragg peak depth-dose and SOBP distributions in simulation has good agreement with measurements. In overall, the study showed that Geant4 based can be fully applied in the heavy-ion therapy field for simulation, further works need to be carry on to refine and improve the Geant4 MC simulations.

  16. An improved Monte Carlo (MC) dose simulation for charged particle cancer therapy

    International Nuclear Information System (INIS)

    Ying, C. K.; Kamil, W. A.; Shuaib, I. L.; Matsufuji, Naruhiro

    2014-01-01

    Heavy-particle therapy such as carbon ion therapy are more popular nowadays because of the nature characteristics of charged particle and almost no side effect to patients. An effective treatment is achieved with high precision of dose calculation, in this research work, Geant4 based Monte Carlo simulation method has been used to calculate the radiation transport and dose distribution. The simulation have the same setting with the treatment room in Heavy Ion Medical Accelerator, HIMAC. The carbon ion beam at the isocentric gantry nozzle for the therapeutic energy of 290 MeV/u was simulated, experimental work was carried out in National Institute of Radiological Sciences, NIRS, Chiba, Japan by using the HIMAC to confirm the accuracy and qualities dose distribution by MC methods. The Geant4 based simulated dose distribution were verified with measurements for Bragg peak and spread out Bragg peak (SOBP) respectively. The verification of results shows that the Bragg peak depth-dose and SOBP distributions in simulation has good agreement with measurements. In overall, the study showed that Geant4 based can be fully applied in the heavy-ion therapy field for simulation, further works need to be carry on to refine and improve the Geant4 MC simulations

  17. An improved Monte Carlo (MC) dose simulation for charged particle cancer therapy

    International Nuclear Information System (INIS)

    Ying, C.K.; Kamil, W.A.; Shuaib, I.L.; Ying, C.K.; Kamil, W.A.

    2013-01-01

    Full-text: Heavy-particle therapy such as carbon ion therapy are more popular nowadays because of the nature characteristics of charged particle and almost no side effect to patients. An effective treatment is achieved with high precision of dose calculation, in this research work, Geant4 based Monte Carlo simulation method has been used to calculate the radiation transport and dose distribution. The simulation have the same setting with the treatment room in Heavy Ion Medical Accelerator, HIMAC. The carbon ion beam at the isocentric gantry nozzle for the therapeutic energy of 290 MeV/u was simulated, experimental work was carried out in National Institute of Radiological Sciences, NIRS, Chiba, Japan by using the HIMAC to confirm the accuracy and qualities dose distribution by MC methods. The Geant4 based simulated dose distribution were verified with measurements for Bragg peak and spread out Bragg peak (SOBP) respectively. The verification of results shows that the Bragg peak depth-dose and SOBP distributions in simulation has good agreement with measurements. In overall, the study showed that Geant4 based can be fully applied in the heavy ion therapy field for simulation, further works need to be carry on to refine and improve the Geant4 MC simulations. (author)

  18. Is prolonged infusion of piperacillin/tazobactam and meropenem in critically ill patients associated with improved pharmacokinetic/pharmacodynamic and patient outcomes? An observation from the Defining Antibiotic Levels in Intensive care unit patients (DALI) cohort.

    Science.gov (United States)

    Abdul-Aziz, Mohd H; Lipman, Jeffrey; Akova, Murat; Bassetti, Matteo; De Waele, Jan J; Dimopoulos, George; Dulhunty, Joel; Kaukonen, Kirsi-Maija; Koulenti, Despoina; Martin, Claude; Montravers, Philippe; Rello, Jordi; Rhodes, Andrew; Starr, Therese; Wallis, Steven C; Roberts, Jason A

    2016-01-01

    We utilized the database of the Defining Antibiotic Levels in Intensive care unit patients (DALI) study to statistically compare the pharmacokinetic/pharmacodynamic and clinical outcomes between prolonged-infusion and intermittent-bolus dosing of piperacillin/tazobactam and meropenem in critically ill patients using inclusion criteria similar to those used in previous prospective studies. This was a post hoc analysis of a prospective, multicentre pharmacokinetic point-prevalence study (DALI), which recruited a large cohort of critically ill patients from 68 ICUs across 10 countries. Of the 211 patients receiving piperacillin/tazobactam and meropenem in the DALI study, 182 met inclusion criteria. Overall, 89.0% (162/182) of patients achieved the most conservative target of 50% fT>MIC (time over which unbound or free drug concentration remains above the MIC). Decreasing creatinine clearance and the use of prolonged infusion significantly increased the PTA for most pharmacokinetic/pharmacodynamic targets. In the subgroup of patients who had respiratory infection, patients receiving β-lactams via prolonged infusion demonstrated significantly better 30 day survival when compared with intermittent-bolus patients [86.2% (25/29) versus 56.7% (17/30); P = 0.012]. Additionally, in patients with a SOFA score of ≥9, administration by prolonged infusion compared with intermittent-bolus dosing demonstrated significantly better clinical cure [73.3% (11/15) versus 35.0% (7/20); P = 0.035] and survival rates [73.3% (11/15) versus 25.0% (5/20); P = 0.025]. Analysis of this large dataset has provided additional data on the niche benefits of administration of piperacillin/tazobactam and meropenem by prolonged infusion in critically ill patients, particularly for patients with respiratory infections. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e

  19. High-Dose Methylprednisolone for Veno-Occlusive Disease of the Liver in Pediatric Hematopoietic Stem Cell Transplantation Recipients

    Science.gov (United States)

    Myers, Kasiani C.; Lawrence, Julia; Marsh, Rebecca A.; Davies, Stella M.; Jodele, Sonata

    2017-01-01

    Veno-occlusive disease (VOD) of the liver is a well-recognized serious complication of hematopoietic stem cell transplantation (HSCT), with few successful treatment modalities available for severe disease. Some reports have demonstrated success in adults with the use of high-dose steroid therapy, but experience in the pediatric population is lacking. We retrospectively reviewed HSCT patients treated at our institution since 2003 and identified 15 (2.4%) who developed VOD. Of these, nine (60%) were treated with intravenous high-dose methylprednisolone (500 mg/m2 per dose every 12 hours for six doses). Steroid therapy was initiated at or before first ultrasound evidence of reversal of portal venous flow and before meeting criteria for initiation of defibrotide therapy. Four patients were also treated with defibrotide starting 2 to 5 days after initiation of steroids. Eight of nine patients (88%) with VOD were diagnosed with multiorgan failure. Response to high-dose steroid therapy as defined by decrease in bilirubin by 50% in 10 days from therapy initiation was noted in six of nine patients (67%), occurring within 3 to 6 days of steroid therapy. Two patients died from multiorgan failure due to VOD. Seven survivors of VOD recovered at the median 6 days (range, 5 to 38) from VOD diagnosis. Overall, VOD survival as a group was 78%; however, survival among responders was 100%. No serious toxicities related to high-dose steroid therapy were observed. We conclude that high-dose steroid therapy if initiated early may reverse VOD of the liver in pediatric HSCT patients, abrogating the need for defibrotide therapy with its associated toxicities and regulatory difficulties. PMID:23211838

  20. Phase I Escalating-Dose Trial of CAR-T Therapy Targeting CEA+ Metastatic Colorectal Cancers.

    Science.gov (United States)

    Zhang, Chengcheng; Wang, Zhe; Yang, Zhi; Wang, Meiling; Li, Shiqi; Li, Yunyan; Zhang, Rui; Xiong, Zhouxing; Wei, Zhihao; Shen, Junjie; Luo, Yongli; Zhang, Qianzhen; Liu, Limei; Qin, Hong; Liu, Wei; Wu, Feng; Chen, Wei; Pan, Feng; Zhang, Xianquan; Bie, Ping; Liang, Houjie; Pecher, Gabriele; Qian, Cheng

    2017-05-03

    Chimeric antigen receptor T (CAR-T) cells have shown promising efficacy in treatment of hematological malignancies, but its applications in solid tumors need further exploration. In this study, we investigated CAR-T therapy targeting carcino-embryonic antigen (CEA)-positive colorectal cancer (CRC) patients with metastases to evaluate its safety and efficacy. Five escalating dose levels (DLs) (1 × 10 5 to 1 × 10 8 /CAR + /kg cells) of CAR-T were applied in 10 CRC patients. Our data showed that severe adverse events related to CAR-T therapy were not observed. Of the 10 patients, 7 patients who experienced progressive disease (PD) in previous treatments had stable disease after CAR-T therapy. Two patients remained with stable disease for more than 30 weeks, and two patients showed tumor shrinkage by positron emission tomography (PET)/computed tomography (CT) and MRI analysis, respectively. Decline of serum CEA level was apparent in most patients even in long-term observation. Furthermore, we observed persistence of CAR-T cells in peripheral blood of patients receiving high doses of CAR-T therapy. Importantly, we observed CAR-T cell proliferation especially in patients after a second CAR-T therapy. Taken together, we demonstrated that CEA CAR-T cell therapy was well tolerated in CEA + CRC patients even in high doses, and some efficacy was observed in most of the treated patients. Copyright © 2017 The American Society of Gene and Cell Therapy. Published by Elsevier Inc. All rights reserved.

  1. Standard dose 131I therapy for hyperthyroidism caused by autonomously functioning thyroid nodules

    International Nuclear Information System (INIS)

    Fui, S.C.N.T.; Maisey, M.N.

    1979-01-01

    Thirty-one patients with hyperthyroidism shown on scintigrams to have autonomously functioning thyroid nodules were treated with a standard dose of 15mCi of 131 I. Of thirty patients who have been followed up for at least 6 months to over 3 years, all but one patient were euthyroid after a single dose. Repeat scintigram and Thyrotropin Releasing Hormone test after therapy confirmed that twenty-five patients were cured of the disease. Only one patient developed hypothyroidism. This simplified dose regimen of radioiodine is effective in the treatment of hyperthyroidism caused by autonomously functioning nodules and is not complicated by the high incidence of hyperthyroidism that is observed following radioiodine therapy of Grave's disease. (author)

  2. Targeting the cell wall of Mycobacterium tuberculosis: a molecular modeling investigation of the interaction of imipenem and meropenem with L,D-transpeptidase 2.

    Science.gov (United States)

    Silva, José Rogério A; Bishai, William R; Govender, Thavendran; Lamichhane, Gyanu; Maguire, Glenn E M; Kruger, Hendrik G; Lameira, Jeronimo; Alves, Cláudio N

    2016-01-01

    The single crystal X-ray structure of the extracellular portion of the L,D-transpeptidase (ex-LdtMt2 - residues 120-408) enzyme was recently reported. It was observed that imipenem and meropenem inhibit activity of this enzyme, responsible for generating L,D-transpeptide linkages in the peptidoglycan layer of Mycobacterium tuberculosis. Imipenem is more active and isothermal titration calorimetry experiments revealed that meropenem is subjected to an entropy penalty upon binding to the enzyme. Herein, we report a molecular modeling approach to obtain a molecular view of the inhibitor/enzyme interactions. The average binding free energies for nine commercially available inhibitors were calculated using MM/GBSA and Solvation Interaction Energy (SIE) approaches and the calculated energies corresponded well with the available experimentally observed results. The method reproduces the same order of binding energies as experimentally observed for imipenem and meropenem. We have also demonstrated that SIE is a reasonably accurate and cost-effective free energy method, which can be used to predict carbapenem affinities for this enzyme. A theoretical explanation was offered for the experimental entropy penalty observed for meropenem, creating optimism that this computational model can serve as a potential computational model for other researchers in the field.

  3. Dose Recalculation and the Dose-Guided Radiation Therapy (DGRT) Process Using Megavoltage Cone-Beam CT

    International Nuclear Information System (INIS)

    Cheung, Joey; Aubry, Jean-Francois; Yom, Sue S.; Gottschalk, Alexander R.; Celi, Juan Carlos; Pouliot, Jean

    2009-01-01

    Purpose: At University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT). Materials and Methods: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment. Results: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D 1 increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D 5 dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk. Conclusions: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

  4. Pediatric Obesity: Pharmacokinetic Alterations and Effects on Antimicrobial Dosing.

    Science.gov (United States)

    Natale, Stephanie; Bradley, John; Nguyen, William Huy; Tran, Tri; Ny, Pamela; La, Kirsten; Vivian, Eva; Le, Jennifer

    2017-03-01

    Limited data exist for appropriate drug dosing in obese children. This comprehensive review summarizes pharmacokinetic (PK) alterations that occur with age and obesity, and these effects on antimicrobial dosing. A thorough comparison of different measures of body weight and specific antimicrobial agents including cefazolin, cefepime, ceftazidime, daptomycin, doripenem, gentamicin, linezolid, meropenem, piperacillin-tazobactam, tobramycin, vancomycin, and voriconazole is presented. PubMed (1966-July 2015) and Cochrane Library searches were performed using these key terms: children, pharmacokinetic, obesity, overweight, body mass index, ideal body weight, lean body weight, body composition, and specific antimicrobial drugs. PK studies in obese children and, if necessary, data from adult studies were summarized. Knowledge of PK alterations stemming from physiologic changes that occur with age from the neonate to adolescent, as well as those that result from increased body fat, become an essential first step toward optimizing drug dosing in obese children. Excessive amounts of adipose tissue contribute significantly to body size, total body water content, and organ size and function that may modify drug distribution and clearance. PK studies that evaluated antimicrobial dosing primarily used total (or actual) body weight (TBW) for loading doses and TBW or adjusted body weight for maintenance doses, depending on the drugs' properties and dosing units. PK studies in obese children are imperative to elucidate drug distribution, clearance, and, consequently, the dose required for effective therapy in these children. Future studies should evaluate the effects of both age and obesity on drug dosing because the incidence of obesity is increasing in pediatric patients. © 2017 Pharmacotherapy Publications, Inc.

  5. Low-dose add-back therapy during postoperative GnRH agonist treatment

    Directory of Open Access Journals (Sweden)

    Hsiao-Wen Tsai

    2016-02-01

    Conclusion: Low dose add-back therapy could effectively ameliorate hypoestrogenic side effects and simultaneously maintain the therapeutic response of GnRH agonist treatment. The treatment dropout was lower compared with a regular dose. Therefore, low dose add-back therapy can be considered a treatment choice during postoperative GnRH agonist treatment.

  6. Short-time, high-dosage penicillin infusion therapy of syphilis

    DEFF Research Database (Denmark)

    Lomholt, Hans; Poulsen, Asmus; Brandrup, Flemming

    2003-01-01

    The optimal dosage and duration of penicillin treatment for the various stages of syphilis are not known. We present data on 20 patients with syphilis (primary, secondary or latent) treated with high-dose, short-time penicillin infusion therapy. Patients were given 10 MIU of penicillin G intraven......The optimal dosage and duration of penicillin treatment for the various stages of syphilis are not known. We present data on 20 patients with syphilis (primary, secondary or latent) treated with high-dose, short-time penicillin infusion therapy. Patients were given 10 MIU of penicillin G...

  7. Scatter Dose in Patients in Radiation Therapy

    International Nuclear Information System (INIS)

    Schmidt, W. F. O.

    2003-01-01

    Patients undergoing radiation therapy are often treated with high energy radiation (bremsstrahlung) which causes scatter doses in the patients from various sources as photon scatter coming from collimator, gantry, patient, patient table or room (walls, floor, air) or particle doses resulting from gamma-particle reactions in the atomic nucleus if the photon energies are above 8 MeV. In the last years new treatment techniques like IMRT (esp the step-and-shoot- or the MIMIC-techniques) have increased interest in these topics again. In the lecture an overview about recent measurements on scatter doses resulting from gantry, table and room shall be given. Scatter doses resulting from the volume treated in the patient to other critical parts of the body like eyes, ovarii etc. have been measured in two diploma works in our institute and are compared with a program (PERIDOSE; van der Giessen, Netherlands) to estimate them. In some cases these scatter doses have led to changes of treatment modalities. Also an overview and estimation of doses resulting from photon-particle interactions is given according to a publication from Gudowska et al.(Gudowska I, Brahme A, Andreo P, Gudowski W, Kierkegaard J. Calculation of absorbed dose and biological effectiveness from photonuclear reactions in a bremsstrahlung beam of end point 50 MeV. Phys Med Biol 1999; 44(9):2099-2125.). Energy dose has been calculated with Monte Carlo-methods and is compared with analytical methods for 50 MV bremsstrahlung. From these data biologically effective doses from particles in different depths of the body can be estimated also for energies used in normal radiotherapy. (author)

  8. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tome, Wolfgang A. [Department of Human Oncology, University of Wisconsin-Madison, WI, 53792 (United States); Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, VIC 3002 (Australia) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Human Oncology, University of Wisconsin-Madison, WI 53792 (United States); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia) and Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur (Malaysia); Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Einstein Institute of Oncophysics, Albert Einstein College of Medicine of Yeshiva University, Bronx, New York 10461 (United States) and Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2012-08-15

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed 'Super Sampling' involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  9. Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Bayliss, Adam; Wong, Jeannie Hsiu Ding; Rosenfeld, Anatoly B.; Tomé, Wolfgang A.

    2012-01-01

    Purpose: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. Methods: The correction method, termed “Super Sampling” involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). Results: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. Conclusions: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.

  10. Effect of extended infusion of meropenem and nebulized amikacin on Gram-negative multidrug-resistant ventilator-associated pneumonia

    Directory of Open Access Journals (Sweden)

    Mona Ahmed Ammar

    2018-01-01

    Conclusions: Adding nebulized amikacin to systemic antibiotics in patients with VAP caused by Gram-negative MDRO may offer efficacy benefits, and the use of extended infusions of meropenem could improve the clinical outcomes in critically ill populations.

  11. High-dose Sulbactam Treatment for Ventilator-Associated Pneumonia Caused by Carbapenem-Resistant

    Directory of Open Access Journals (Sweden)

    In Beom Jeong

    2016-11-01

    Full Text Available Background Several antibiotics can be used to treat ventilator-associated pneumonia caused by carbapenem-resistant A. baumannii (CRAB-VAP including high-dose sulbactam. However, the effectiveness of high-dose sulbactam therapy is not well known. We report our experience with high-dose sulbactam for treatment of CRAB-VAP. Methods Medical records of patients with CRAB-VAP who were given high-dose sulbactam between May 2013 and June 2015 were reviewed. Results Fifty-eight patients with CRAB-VAP were treated with high-dose sulbactam. The mean age was 72.0 ± 15.2 years, and the acute physiology and chronic health evaluation II (APACHE II score was 15.1 ± 5.10 at the time of CRAB-VAP diagnosis. Early clinical improvement was observed in 65.5% of patients, and 30-day mortality was 29.3%. Early clinical failure (odds ratio [OR]: 8.720, confidence interval [CI]: 1.346-56.484; p = 0.023 and APACHE II score ≥ 14 at CRAB-VAP diagnosis (OR: 10.934, CI: 1.047-114.148; p = 0.046 were associated with 30-day mortality. Conclusions High-dose sulbactam therapy may be effective for the treatment of CRAB-VAP. However, early clinical failure was observed in 35% of patients and was associated with poor outcome.

  12. Radiation-Induced Leukemia at Doses Relevant to Radiation Therapy: Modeling Mechanisms and Estimating Risks

    Science.gov (United States)

    Shuryak, Igor; Sachs, Rainer K.; Hlatky, Lynn; Mark P. Little; Hahnfeldt, Philip; Brenner, David J.

    2006-01-01

    Because many cancer patients are diagnosed earlier and live longer than in the past, second cancers induced by radiation therapy have become a clinically significant issue. An earlier biologically based model that was designed to estimate risks of high-dose radiation induced solid cancers included initiation of stem cells to a premalignant state, inactivation of stem cells at high radiation doses, and proliferation of stem cells during cellular repopulation after inactivation. This earlier model predicted the risks of solid tumors induced by radiation therapy but overestimated the corresponding leukemia risks. Methods: To extend the model to radiation-induced leukemias, we analyzed in addition to cellular initiation, inactivation, and proliferation a repopulation mechanism specific to the hematopoietic system: long-range migration through the blood stream of hematopoietic stem cells (HSCs) from distant locations. Parameters for the model were derived from HSC biologic data in the literature and from leukemia risks among atomic bomb survivors v^ ho were subjected to much lower radiation doses. Results: Proliferating HSCs that migrate from sites distant from the high-dose region include few preleukemic HSCs, thus decreasing the high-dose leukemia risk. The extended model for leukemia provides risk estimates that are consistent with epidemiologic data for leukemia risk associated with radiation therapy over a wide dose range. For example, when applied to an earlier case-control study of 110000 women undergoing radiotherapy for uterine cancer, the model predicted an excess relative risk (ERR) of 1.9 for leukemia among women who received a large inhomogeneous fractionated external beam dose to the bone marrow (mean = 14.9 Gy), consistent with the measured ERR (2.0, 95% confidence interval [CI] = 0.2 to 6.4; from 3.6 cases expected and 11 cases observed). As a corresponding example for brachytherapy, the predicted ERR of 0.80 among women who received an inhomogeneous low-dose

  13. Radiation Dose-Response Model for Locally Advanced Rectal Cancer After Preoperative Chemoradiation Therapy

    International Nuclear Information System (INIS)

    Appelt, Ane L.; Pløen, John; Vogelius, Ivan R.; Bentzen, Søren M.; Jakobsen, Anders

    2013-01-01

    Purpose: Preoperative chemoradiation therapy (CRT) is part of the standard treatment of locally advanced rectal cancers. Tumor regression at the time of operation is desirable, but not much is known about the relationship between radiation dose and tumor regression. In the present study we estimated radiation dose-response curves for various grades of tumor regression after preoperative CRT. Methods and Materials: A total of 222 patients, treated with consistent chemotherapy and radiation therapy techniques, were considered for the analysis. Radiation therapy consisted of a combination of external-beam radiation therapy and brachytherapy. Response at the time of operation was evaluated from the histopathologic specimen and graded on a 5-point scale (TRG1-5). The probability of achieving complete, major, and partial response was analyzed by ordinal logistic regression, and the effect of including clinical parameters in the model was examined. The radiation dose-response relationship for a specific grade of histopathologic tumor regression was parameterized in terms of the dose required for 50% response, D 50,i , and the normalized dose-response gradient, γ 50,i . Results: A highly significant dose-response relationship was found (P=.002). For complete response (TRG1), the dose-response parameters were D 50,TRG1 = 92.0 Gy (95% confidence interval [CI] 79.3-144.9 Gy), γ 50,TRG1 = 0.982 (CI 0.533-1.429), and for major response (TRG1-2) D 50,TRG1 and 2 = 72.1 Gy (CI 65.3-94.0 Gy), γ 50,TRG1 and 2 = 0.770 (CI 0.338-1.201). Tumor size and N category both had a significant effect on the dose-response relationships. Conclusions: This study demonstrated a significant dose-response relationship for tumor regression after preoperative CRT for locally advanced rectal cancer for tumor dose levels in the range of 50.4-70 Gy, which is higher than the dose range usually considered.

  14. Characterization of a microDiamond detector in high-dose-per-pulse electron beams for intra operative radiation therapy.

    Science.gov (United States)

    Di Venanzio, C; Marinelli, Marco; Tonnetti, A; Verona-Rinati, G; Falco, M D; Pimpinella, M; Ciccotelli, A; De Stefano, S; Felici, G; Marangoni, F

    2015-12-01

    To characterize a synthetic diamond dosimeter (PTW Freiburg microDiamond 60019) in high dose-per-pulse electron beams produced by an Intra Operative Radiation Therapy (IORT) dedicated accelerator. The dosimetric properties of the microDiamond were assessed under 6, 8 and 9 MeV electron beams by a NOVAC11 mobile accelerator (Sordina IORT Technologies S.p.A.). The characterization was carried out with dose-per-pulse ranging from 26 to 105 mGy per pulse. The microDiamond performance was compared with an Advanced Markus ionization chamber and a PTW silicon diode E in terms of dose linearity, percentage depth dose (PDD) curves, beam profiles and output factors. A good linearity of the microDiamond response was verified in the dose range from 0.2 Gy to 28 Gy. A sensitivity of 1.29 nC/Gy was measured under IORT electron beams, resulting within 1% with respect to the one obtained in reference condition under (60)Co gamma irradiation. PDD measurements were found in agreement with the ones by the reference dosimeters, with differences in R50 values below 0.3 mm. Profile measurements evidenced a high spatial resolution of the microDiamond, slightly worse than the one of the silicon diode. The penumbra widths measured by the microDiamond resulted approximately 0.5 mm larger than the ones by the Silicon diode. Output factors measured by the microDiamond were found within 2% with those obtained by the Advanced Markus down to 3 cm diameter field sizes. The microDiamond dosimeter was demonstrated to be suitable for precise dosimetry in IORT applications under high dose-per-pulse conditions. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Quantifying the Combined Effect of Radiation Therapy and Hyperthermia in Terms of Equivalent Dose Distributions

    International Nuclear Information System (INIS)

    Kok, H. Petra; Crezee, Johannes; Franken, Nicolaas A.P.; Stalpers, Lukas J.A.; Barendsen, Gerrit W.; Bel, Arjan

    2014-01-01

    Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia. Methods and Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system. The temperature-dependent parameters α (Gy −1 ) and β (Gy −2 ) of the linear–quadratic model for prostate cancer were estimated from the literature. No thermal enhancement was assumed for normal tissue. The intensity modulated radiation therapy plans and temperature distributions were exported to our in-house-developed radiation therapy treatment planning system, APlan, and equivalent dose distributions without hyperthermia were calculated voxel by voxel using the linear–quadratic model. Results: The planned average tumor temperatures T90, T50, and T10 in the planning target volume were 40.5°C, 41.6°C, and 42.4°C, respectively. The planned minimum, mean, and maximum radiation therapy doses were 62.9 Gy, 76.0 Gy, and 81.0 Gy, respectively. Adding hyperthermia yielded an equivalent dose distribution with an extended 95% isodose level. The equivalent minimum, mean, and maximum doses reflecting the radiosensitization by hyperthermia were 70.3 Gy, 86.3 Gy, and 93.6 Gy, respectively, for a linear increase of α with temperature. This can be considered similar to a dose escalation with a substantial increase in tumor control probability for high-risk prostate carcinoma. Conclusion: A model to quantify the effect of combined radiation therapy and hyperthermia in terms of equivalent dose distributions was presented. This model is particularly instructive to estimate the potential effects of interaction from different treatment

  16. Dose measurement using radiochromic lms and Monte Carlo simulation for hadron-therapy

    International Nuclear Information System (INIS)

    Zahra, N.

    2010-06-01

    Because of the increase in dose at the end of the range of ions, dose delivery during patient treatment with hadron-therapy should be controlled with high precision. Monte Carlo codes are now considered mandatory for validation of clinical treatment planning and as a new tool for dosimetry of ion beams. In this work, we aimed to calculate the absorbed dose using Monte Carlo simulation Geant4/Gate. The effect on the dose calculation accuracy of different Geant4 parameters has been studied for mono-energetic carbon ion beams of 300 MeV/u in water. The parameters are: the production threshold of secondary particles and the maximum step limiter of the particle track. Tolerated criterion were chosen to meet the precision required in radiotherapy in term of value and dose localisation (2%, 2 mm respectively) and to obtain the best compromise on dose distribution and computational time. We propose here the values of parameters in order to satisfy the precision required. In the second part of this work, we study the response of radiochromic films MD-v2-55 for quality control in proton and carbon ion beams. We have particularly observed and studied the quenching effect of dosimetric films for high LET (≥20 keV/μm) irradiation in homogeneous and heterogeneous media. This effect is due to the high ionization density around the track of the particle. We have developed a method to predict the response of radiochromic films taking into account the saturation effect. This model is called the RADIS model for 'Radiochromic films Dosimetry for Ions using Simulations'. It is based on the response of films under photon irradiations and the saturation of films due to high linear energy deposit calculated by Monte Carlo. Different beams were used in this study and aimed to validate the model for hadron-therapy applications: carbon ions, protons and photons at different energies. Experiments were performed at Grand Accelerateur National d'Ions Lourds (GANIL), Proton therapy center of

  17. Clinical result of high-dose rate intraluminal brachytherapy for esophageal carcinoma with a remote afterloading system

    International Nuclear Information System (INIS)

    Fukuda, Haruyuki; Nakajima, Toshifumi; Tada, Takuhito; Tanaka, Masahiro; Tsumura, Masashi; Onoyama, Yasuto

    1992-01-01

    During the period from 1977 through 1987, 105 patients with esophageal carcinoma were radically treated by radiotherapy. Forty-six patients receiving therapy before August 1982 were all treated by external beam therapy alone (Group 1). Since September 1982, 26 patients were treated by external beam therapy alone (Group 2) and 33 patients were treated by high-dose-rate intraluminal brachytherapy with a remote afterloading system combined with external beam therapy (Group 3). Dose of external beam therapy for Group 1, Group 2 and Group 3 patients were 66.7 Gy, 68.7 Gy and 55.9 Gy on the average. The intraluminal brachytherapy was performed with a total dose of 12 Gy consisting of 3 Gy twice a week. Ten of 72 patients (14%) treated by external beam therapy alone achieved complete response, whereas 14 of 33 patients (42%) treated by high-dose-rate intraluminal brachytherapy combined with external beam therapy had complete response. One-, and 3-year survival rates were 36% and 10% in the Group 1, 32% and 12% in the Group 2 and 56% and 36% in the Group 3. For Group 3, good survival rate was obtained in tumorous type and serrated type. Patients with tumor of less than 5 cm in Group 3 had good survival. The data suggest that the high-dose-rate intraluminal bracytherapy prescribed as a boost therapy following external beam therapy is an effective therapy modality for esophageal carcinoma which is of non-circumferential tumor or less than 5 cm. (author)

  18. Maximal safe dose of I-131 after failure of standard fixed dose therapy in patients with differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Lee, Jong-Jin; Chung, June-Key; Kim, Sung-Eun; Kang, Won-Jun; Park, Do-Joon; Lee, Dong-Soo; Cho, Bo-Youn; Lee, Myung-Chul

    2008-01-01

    The maximal safe dose (MSD) on the basis of bone marrow irradiation levels allows the delivery of a large amount of I-131 to thyroid cancer tissue. The efficacy of MSD therapy in differentiated metastatic thyroid cancers that persisted after conventional fixed dose therapy is investigated. Forty-seven differentiated thyroid carcinoma patients with non-responsive residual disease despite repetitive fixed dose I-131 therapy were enrolled in this study. Their postoperative pathologies were 43 papillary carcinomas and 4 follicular carcinomas. The MSD was calculated with the Memorial Sloan-Kettering Cancer Center protocol using serial blood samples. The MSDs were administered at intervals of 6 months. Treatment responses were evaluated using I-131 whole-body scans and serum thyroglobulin measurements. The mean calculated MSD was 12.5±2.1 GBq (339.6±57.5 mCi). Of the 46 patients, 7 (14.9%) showed complete remission, 15 (31.9%) partial remission, 19 (40.4%) stable disease, and 6 (12.8%) disease progression. Of the patients who showed complete or partial remission, 15 (65%) showed response after the first MSD session and 6 (26%) showed response after the second session. Twenty-nine patients (62%) experienced transient cytopenia after therapy, but three did not recover to the baseline level. The maximal safe dose provides an effective means of treatment in patients who failed to respond adequately to conventional fixed dose therapy. I-131 MSD therapy can be considered in patients who fail fixed dose therapy. (author)

  19. Local dose enhancement in radiation therapy: Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Silva, Laura E. da; Nicolucci, Patricia

    2014-01-01

    The development of nanotechnology has boosted the use of nanoparticles in radiation therapy in order to achieve greater therapeutic ratio between tumor and healthy tissues. Gold has been shown to be most suitable to this task due to the high biocompatibility and high atomic number, which contributes to a better in vivo distribution and for the local energy deposition. As a result, this study proposes to study, nanoparticle in the tumor cell. At a range of 11 nm from the nanoparticle surface, results have shown an absorbed dose 141 times higher for the medium with the gold nanoparticle compared to the water for an incident energy spectrum with maximum photon energy of 50 keV. It was also noted that when only scattered radiation is interacting with the gold nanoparticles, the dose was 134 times higher compared to enhanced local dose that remained significant even for scattered radiation. (author)

  20. High Phenobarbital Clearance During Continuous Renal Replacement Therapy

    Science.gov (United States)

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-01-01

    Abstract Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring. A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure. Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus. The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed. Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring. PMID:25101986

  1. Multi-Institutional Phase II Study of High-Dose Hypofractionated Proton Beam Therapy in Patients With Localized, Unresectable Hepatocellular Carcinoma and Intrahepatic Cholangiocarcinoma.

    Science.gov (United States)

    Hong, Theodore S; Wo, Jennifer Y; Yeap, Beow Y; Ben-Josef, Edgar; McDonnell, Erin I; Blaszkowsky, Lawrence S; Kwak, Eunice L; Allen, Jill N; Clark, Jeffrey W; Goyal, Lipika; Murphy, Janet E; Javle, Milind M; Wolfgang, John A; Drapek, Lorraine C; Arellano, Ronald S; Mamon, Harvey J; Mullen, John T; Yoon, Sam S; Tanabe, Kenneth K; Ferrone, Cristina R; Ryan, David P; DeLaney, Thomas F; Crane, Christopher H; Zhu, Andrew X

    2016-02-10

    To evaluate the efficacy and safety of high-dose, hypofractionated proton beam therapy for hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC). In this single-arm, phase II, multi-institutional study, 92 patients with biopsy-confirmed HCC or ICC, determined to be unresectable by multidisciplinary review, with a Child-Turcotte-Pugh score (CTP) of A or B, ECOG performance status of 0 to 2, no extrahepatic disease, and no prior radiation received 15 fractions of proton therapy to a maximum total dose of 67.5 Gy equivalent. Sample size was calculated to demonstrate > 80% local control (LC) defined by Response Evaluation Criteria in Solid Tumors (RECIST) 1.0 criteria at 2 years for HCC patients, with the parallel goal of obtaining acceptable precision for estimating outcomes for ICC. Eighty-three patients were evaluable: 44 with HCC, 37 with ICC, and two with mixed HCC/ICC. The CTP score was A for 79.5% of patients and B for 15.7%; 4.8% of patients had no cirrhosis. Prior treatment had been given to 31.8% of HCC patients and 61.5% of ICC patients. The median maximum dimension was 5.0 cm (range, 1.9 to 12.0 cm) for HCC patients and 6.0 cm (range, 2.2 to 10.9 cm) for ICC patients. Multiple tumors were present in 27.3% of HCC patients and in 12.8% of ICC patients. Tumor vascular thrombosis was present in 29.5% of HCC patients and in 28.2% of ICC patients. The median dose delivered to both HCC and ICC patients was 58.0 Gy. With a median follow-up among survivors of 19.5 months, the LC rate at 2 years was 94.8% for HCC and 94.1% for ICC. The overall survival rate at 2 years was 63.2% for HCC and 46.5% ICC. High-dose hypofractionated proton therapy demonstrated high LC rates for HCC and ICC safely, supporting ongoing phase III trials of radiation in HCC and ICC. © 2015 by American Society of Clinical Oncology.

  2. Real-time dose compensation methods for scanned ion beam therapy of moving tumors

    International Nuclear Information System (INIS)

    Luechtenborg, Robert

    2012-01-01

    Scanned ion beam therapy provides highly tumor-conformal treatments. So far, only tumors showing no considerable motion during therapy have been treated as tumor motion and dynamic beam delivery interfere, causing dose deteriorations. One proposed technique to mitigate these deteriorations is beam tracking (BT), which adapts the beam position to the moving tumor. Despite application of BT, dose deviations can occur in the case of non-translational motion. In this work, real-time dose compensation combined with beam tracking (RDBT) has been implemented into the control system to compensate these dose changes by adaptation of nominal particle numbers during irradiation. Compared to BT, significantly reduced dose deviations were measured using RDBT. Treatment planning studies for lung cancer patients including the increased biological effectiveness of ions revealed a significantly reduced over-dose level (3/5 patients) as well as significantly improved dose homogeneity (4/5 patients) for RDBT. Based on these findings, real-time dose compensated re-scanning (RDRS) has been proposed that potentially supersedes the technically complex fast energy adaptation necessary for BT and RDBT. Significantly improved conformity compared to re-scanning, i.e., averaging of dose deviations by repeated irradiation, was measured in film irradiations. Simulations comparing RDRS to BT revealed reduced under- and overdoses of the former method.

  3. Our experience of high dose I-131 therapy in 75 patients with well differentiated carcinoma thyroid followed up over 5 years

    International Nuclear Information System (INIS)

    Dougall, P.; Kumar, A.; Ashok, P.; Chinwan, B.P.; Khan, B.; Pandey, D.; Joshi, N.D.

    2005-01-01

    Thyroid cancer is the most common endocrine malignancy. The epidemiology of thyroid cancer is variable, depending on the geographic location of the patient population. Well differentiated thyroid cancer (WTC), is responsive to high dose I-131 treatment, and is the most accepted form of therapy, even though the dose administered for ablation of residual thyroid tissue maybe controversial. At our centre, 75 patients of WTC, mean age 42.4 years, 22 males and 53 females (M:F 1:2.4), were treated with high dose oral I-131 therapy with a Total Mean Dose (TMD) of 263.6 mCi, 4 - 6 weeks post thyroidectomy. They were followed up over a period of 6 years. Twenty ( 26.7%) patients had follicular cancer (FC), 47 (62.7%) papillary cancer (PC) and 8 (10.7%) were mixed (MC), on histopathology, at presentation. 38 (50.7%) patients had only residual thyroid tissue (RTT) on I-131 whole body bone scan (WBS) and 37 (49.3%) presented with metastatic disease (MD) at the time of therapy. Of the 37 patients with MD, 21 (56.8%) had metastases to the lymph nodes, 6 (16.2%) to the lungs, 4 (10.8%) to bone, 3 (8.1%) to bone and lung, and 4 (10.8%) to lung plus lymph nodes. Twenty-three patients (7 FC , 13 - PC and 3 MC; 6 RTT, 17 - MD) , received more than one dose of I-131 with a TMD of 422.7 mCi (Range 88 1590 mCi ). 52 patients (13 FC, 34 PC, 5 MC; 20 MD and 32 RTT) received a single TMD of 104.4 (Range 39.5 219 mCi). On follow-up, 3 patients of FC with MD (2 lung metastasis and 1 with extensive lymph node metastasis), died within 3 months 2 years of therapy. 3 patients of MD (2 FC, 1-MC; 2 bone metastasis and 1 bone with lung metastasis) died after 5 .5 years, Of the 6 patients who died, 5 were FC and only 1 was MC. 2 patients with MD to lungs and bone had received a single dose and were lost to follow up. All patients with PC and FC with only RTT, were surviving at the end of 5 years. None of the patients with MD to lymph nodes died at the end of 5 years, either receiving single or

  4. The incidence of breast cancer following mantle field radiation therapy as a function of dose and technique

    International Nuclear Information System (INIS)

    Tinger, Alfred; Wasserman, Todd H.; Klein, Eric E.; Miller, Elizabeth A.; Roberts, Tracy; Piephoff, James V.; Kucik, Nancy A.

    1997-01-01

    Purpose: There is an increased incidence of breast cancer following mantle field radiation therapy for Hodgkin's disease (HD). We reviewed the experience at the Mallinckrodt Institute of Radiology (MIR) for radiation factors related to the development of breast cancer after mantle field radiation therapy for HD. Methods: The radiation therapy records of 152 women treated with mantle field irradiation for HD at MIR between 1966-1985 were reviewed for the development of breast cancer and treatment-related factors. All patients had a minimum of 5 years of follow-up. The treatment era (1966-1974 vs. 1975-1985), stage of HD, mediastinal dose, axillary dose, maximum dose from the anterior field (anterior d max dose), the anterior-posterior:posterior-anterior (AP:PA) ratio, age at the time of treatment, length of follow-up, and history of splenectomy were analyzed as possible contributing factors for the development of breast cancer. The observed number of breast cancers was compared to the expected number based on age-adjusted incidences from the Connecticut Tumor Registry. Results: Ten breast cancers occurred in the population. Eight involved an upper outer quadrant. In a multivariate analysis, the development of breast cancer was significantly associated with axillary dose. Patients in the early treatment era were at an increased risk for the development of breast cancer due to high anterior d max and breast doses from weighting the fields anteriorly on a low energy linear accelerator. The use of current radiation therapy techniques was not related to an increased risk of breast cancer with a median follow-up of 13 years. Conclusions: A high dose to the axilla and the anterior d max point is significantly associated with the development of breast cancer after mantle field irradiation for HD. Efforts to protect the breast from high doses will likely lessen the increased risk of breast cancer in women treated with radiation therapy for HD

  5. Motion-Compensated Estimation of Delivered Dose during External BeamRadiation Therapy: Implementation in Philips’ Pinnacle3 Treatment Planning System

    NARCIS (Netherlands)

    Bharat, S.; Parikh, P.; Noel, C.; Meltsner, M.; Bzdusek, K.; Kaus, M.

    2012-01-01

    Purpose: Recent research efforts investigating dose escalation techniques for three-dimensional conformal radiation therapy (3D CRT) andintensity modulated radiation therapy (IMRT) have demonstrated great benefit when high-dose hypofractionated treatment schemes are implemented16,21. The use of

  6. Influence of low- and high-dose radioiodine therapy on oxidative modification of fibrinogen

    International Nuclear Information System (INIS)

    Schweeger-Exeli, I.J.

    2001-10-01

    levels were significantly elevated above 300 mg/dl (p 0.05) and did not change to a significant extent after treatment in both subgroups. Conclusion: Purification of fibrinogen out of small volumes of plasma is feasible in a short period of time and requires only little technical effort. High - dose radioiodine therapy, applied in differentiated thyroid cancer, leads to significantly increased incorporation of carbonyl groups into the fibrinogen molecule. It remains to be elucidated, whether thyroid hormone status itself influences oxidative damage of fibrinogen. Key words: fibrinogen; radioiodine therapy; oxidative modification; isolation techniques; 2,4-dinitrophenylhydrazine. (author)

  7. Reversible, PET-positive, generalized lymphadenopathy and splenomegaly during high-dose interferon-alpha-2b adjuvant therapy for melanoma.

    Science.gov (United States)

    Ridolfi, Laura; Cangini, Delia; Galassi, Riccardo; Passardi, Alessandro; Marzullo, Annamaria; Moretti, Andrea; Framarini, Massimo; Tauceri, Francesca; Serra, Luigi; Chiarion-Sileni, Vanna; Ridolfi, Ruggero

    2008-09-01

    A patient with resected stage III nodular melanoma treated with high-dose interferon-alpha-b2 adjuvant therapy went on to develop generalized lymphadenopathy and splenomegaly. The total body positron emission tomography showed a high F-fluorodeoxyglucose uptake (standardized uptake values >9), indicating possible lymph node and spleen malignancies. Histologic examinations of an axillary lymph node biopsy and an osteomedullar biopsy were negative, excluding both melanoma metastases and hematopoietic tumors. The symptoms completely regressed after suspension of treatment and a follow-up positron emission tomography was negative. It remains to be seen whether this unusual event can be ascribed to an autoimmune phenomenon linked to potential treatment efficacy and survival.

  8. Fractionated stereotactic radiation therapy and single high-dose radiosurgery for acoustic neuroma: early results of a prospective clinical study

    International Nuclear Information System (INIS)

    Meijer, O.W.M.; Wolbers, J.G.; Baayen, J.C.; Slotman, B.J.

    2000-01-01

    Purpose: To prospectively assess the local control and toxicity rate in acoustic neuroma patients treated with linear accelerator-based radiosurgery and fractionated stereotactic radiation therapy. Methods and Materials: We evaluated 37 consecutive patients treated with stereotactic radiation therapy for acoustic neuroma. All patients had progressive tumors, progressive symptoms, or both. Mean tumor diameter was 2.3 cm (range 0.8-3.3) on magnetic resonance (MR) scan. Dentate patients were given a dose of 5 x 4 Gy or 5 x 5 Gy and edentate patients were given a dose of 1 x 10 Gy or 1 x 12.50 Gy prescribed to the 80% isodose. All patients were treated with a single isocenter. Results: With a mean follow-up period of 25 months (range 12-61), the actuarial local control rate at 5 years was 91% (only 1 patient failed). The actuarial rate of hearing preservation at 5 years was 66% in previously-hearing patients. The actuarial rate of freedom from trigeminal nerve toxicity was 97% at 5 years. No patient developed facial nerve toxicity or other complications. Conclusion: In this unselected series, fractionated stereotactic radiation therapy and linear accelerator-based radiosurgery give excellent local control in acoustic neuroma. It combines a high rate of preservation of hearing with a very low rate of other toxicity, although follow-up is relatively short

  9. Quantification of tomography images for dose calculation for diagnosis and therapy in nuclear medicine

    International Nuclear Information System (INIS)

    Massicano, Felipe

    2010-01-01

    The nuclear medicine area has an increasing slope in the therapy of diseases, particularly in the treatment of radiosensitive tumors. Due to the high dose levels in radionuclide therapy, it is very important the accurate quantify of the dose distribution to avoid deleterious effects on healthy tissues. In Brazil, the internal dosimetry system used is the MIRD (Medical Internal Radiation Dose) based on a reference model that does not have adequate patient data to obtain a dose accurate assessment in therapy. However, in recent years, internal radionuclide dosimetry evaluates the spatial dose distribution base ad on information obtained from CT and SPECT or PET images together with the using of Monte Carlo codes. Those systems are called patient-specific dosimetry systems. In the Nuclear Engineering Center at IPEN, this methodology is in development. When the CT images are inserted into the Monte Carlo code MCNP5 through of use of a interface software called SCMS the dosimetry can be accomplished using patient-specific data, resulting in a more accurate energy deposition in organs of interest. This work aim to contribute with the development of part of that patient-specific dosimetry for therapy. To achieve this goal we have proposed three specific objectives: (1) Development of a software to convert images from Computed Tomography (CT) in the tissue parameters (ρ, ω(ι)); (2) Development of a software to perform attenuation correction in nuclear medicine tomographic images (SPECT or PET) and to provide the map of relative activity and (3) Provide data to the SCMS code by these two software. The software developed for the rst specific objective was the Image Converter Computed Tomography (ICCT), which obtained a good accuracy to determine the density and the tissue composition; the elements that had high variation were carbon and oxygen. Fortunately, this variation for the energy range used in radionuclide therapy is not detrimental to the dose distribution. A

  10. Conventional external beam radiation therapy and high dose rate afterloading brachytherapy as a boost for patients older than 70 years

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Salvajoli, Joao Vitor; Fogaroli, Ricardo Cesar; Novaes, Paulo Eduardo R.S.; Maia, Maria Aparecida Conte; Ferrigno, Robson

    2005-01-01

    The treatment options for patients with non metastatic prostate cancer range from observation, radical prostatectomy, radiation therapy, hormonal therapy to various combination of some to all of them. Objective: we evaluated the impact on biochemical control of disease (bNED), acute and late intestinal (GI) and urological (GU) morbidity for a group of patients older than 70 years presenting initial or locally advanced prostate cancer treated with fractionated high dose rate brachytherapy (HDRB) as a boost to conventional external beam radiation therapy (RT) at the Department of Radiation Oncology from Hospital do Cancer A. C. Camargo, Sao Paulo, Brazil. Methods: a total of 56 patients older than 70 were treated from March, 1997 to June, 2002. All patients had prior to HDRB a course of RT to a median dose of 45 Gy. HDRB doses ranged from 16 Gy to 20 Gy, given in 4 fractions. Results: the median age of the patients was 74.4 years (range 70-83) and the median follow-up 33 months (range 24 to 60). The 5-year actuarial bNED rate was 77%. Acute GU and GI morbidity G1-2 were seen in 17.8% and 7.1% of patients, respectively. Late G1 or G2 GU morbidity was seen in 10.7% of the patients, while late G3 morbidity was observed in 7.1% of the patients, represented by urethral strictures. Conclusion: this group of patients had similar bNED rates when compared to literature, with acceptable morbidity rates. (author)

  11. Ultraviolet radiation therapy and UVR dose models

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, David Robert, E-mail: davidrobert.grimes@oncology.ox.ac.uk [School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland and Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Gray Laboratory, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ (United Kingdom)

    2015-01-15

    Ultraviolet radiation (UVR) has been an effective treatment for a number of chronic skin disorders, and its ability to alleviate these conditions has been well documented. Although nonionizing, exposure to ultraviolet (UV) radiation is still damaging to deoxyribonucleic acid integrity, and has a number of unpleasant side effects ranging from erythema (sunburn) to carcinogenesis. As the conditions treated with this therapy tend to be chronic, exposures are repeated and can be high, increasing the lifetime probability of an adverse event or mutagenic effect. Despite the potential detrimental effects, quantitative ultraviolet dosimetry for phototherapy is an underdeveloped area and better dosimetry would allow clinicians to maximize biological effect whilst minimizing the repercussions of overexposure. This review gives a history and insight into the current state of UVR phototherapy, including an overview of biological effects of UVR, a discussion of UVR production, illness treated by this modality, cabin design and the clinical implementation of phototherapy, as well as clinical dose estimation techniques. Several dose models for ultraviolet phototherapy are also examined, and the need for an accurate computational dose estimation method in ultraviolet phototherapy is discussed.

  12. Ultraviolet radiation therapy and UVR dose models

    International Nuclear Information System (INIS)

    Grimes, David Robert

    2015-01-01

    Ultraviolet radiation (UVR) has been an effective treatment for a number of chronic skin disorders, and its ability to alleviate these conditions has been well documented. Although nonionizing, exposure to ultraviolet (UV) radiation is still damaging to deoxyribonucleic acid integrity, and has a number of unpleasant side effects ranging from erythema (sunburn) to carcinogenesis. As the conditions treated with this therapy tend to be chronic, exposures are repeated and can be high, increasing the lifetime probability of an adverse event or mutagenic effect. Despite the potential detrimental effects, quantitative ultraviolet dosimetry for phototherapy is an underdeveloped area and better dosimetry would allow clinicians to maximize biological effect whilst minimizing the repercussions of overexposure. This review gives a history and insight into the current state of UVR phototherapy, including an overview of biological effects of UVR, a discussion of UVR production, illness treated by this modality, cabin design and the clinical implementation of phototherapy, as well as clinical dose estimation techniques. Several dose models for ultraviolet phototherapy are also examined, and the need for an accurate computational dose estimation method in ultraviolet phototherapy is discussed

  13. A Novel Simple Phantom for Verifying the Dose of Radiation Therapy

    Directory of Open Access Journals (Sweden)

    J. H. Lee

    2015-01-01

    Full Text Available A standard protocol of dosimetric measurements is used by the organizations responsible for verifying that the doses delivered in radiation-therapy institutions are within authorized limits. This study evaluated a self-designed simple auditing phantom for use in verifying the dose of radiation therapy; the phantom design, dose audit system, and clinical tests are described. Thermoluminescent dosimeters (TLDs were used as postal dosimeters, and mailable phantoms were produced for use in postal audits. Correction factors are important for converting TLD readout values from phantoms into the absorbed dose in water. The phantom scatter correction factor was used to quantify the difference in the scattered dose between a solid water phantom and homemade phantoms; its value ranged from 1.084 to 1.031. The energy-dependence correction factor was used to compare the TLD readout of the unit dose irradiated by audit beam energies with 60Co in the solid water phantom; its value was 0.99 to 1.01. The setup-condition factor was used to correct for differences in dose-output calibration conditions. Clinical tests of the device calibrating the dose output revealed that the dose deviation was within 3%. Therefore, our homemade phantoms and dosimetric system can be applied for accurately verifying the doses applied in radiation-therapy institutions.

  14. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  15. Sacral chordomas: Impact of high-dose proton/photon-beam radiation therapy combined with or without surgery for primary versus recurrent tumor

    International Nuclear Information System (INIS)

    Park, Lily; De Laney, Thomas F.; Liebsch, Norbert J.; Hornicek, Francis J.; Goldberg, Saveli; Mankin, Henry; Rosenberg, Andrew E.; Rosenthal, Daniel I.; Suit, Herman D.

    2006-01-01

    Purpose: To assess the efficacy of definitive treatment of sacral chordoma by high-dose proton/photon-beam radiation therapy alone or combined with surgery. Methods and Materials: The records of 16 primary and 11 recurrent sacral chordoma patients treated from November 1982 to November 2002 by proton/photon radiation therapy alone (6 patients) or combined with surgery (21 patients) have been analyzed for local control, survival, and treatment-related morbidity. The outcome analysis is based on follow-up information as of 2005. Results: Outcome results show a large difference in local failure rate between patients treated for primary and recurrent chordomas. Local control results by surgery and radiation were 12/14 vs. 1/7 for primary and recurrent lesions. For margin-positive patients, local control results were 10 of 11 and 0 of 5 in the primary and recurrent groups, respectively; the mean follow-up on these locally controlled patients was 8.8 years (4 at 10.3, 12.8, 17, and 21 years). Radiation alone was used in 6 patients, 4 of whom received ≥73.0 Gy (E); local control was observed in 3 of these 4 patients for 2.9, 4.9, and 7.6 years. Conclusion: These data indicate a high local control rate for surgical and radiation treatment of primary (12 of 14) as distinct from recurrent (1 of 7) sacral chordomas. Three of 4 chordomas treated by ≥73.0 Gy (E) of radiation alone had local control; 1 is at 91 months. This indicates that high-dose proton/photon therapy offers an effective treatment option

  16. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ruijie, E-mail: ruijyang@yahoo.com; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-10-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

  17. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    International Nuclear Information System (INIS)

    Yang, Ruijie; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-01-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D 90 of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD 2 ) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D mean (EQD 2 ) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D mean (EQD 2 ) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD 2 ) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

  18. Randomized Phase II Trial of High-Dose Melatonin and Radiation Therapy for RPA Class 2 Patients With Brain Metastases (RTOG 0119)

    International Nuclear Information System (INIS)

    Berk, Lawrence; Berkey, Brian; Rich, Tyvin; Hrushesky, William; Blask, David; Gallagher, Michael; Kudrimoti, Mahesh; McGarry, Ronald C.; Suh, John; Mehta, Minesh

    2007-01-01

    Purpose: To determine if high-dose melatonin for Radiation Therapy Oncology Group (RTOG) recursive partitioning analysis (RPA) Class 2 patients with brain metastases improved survival over historical controls, and to determine if the time of day melatonin was given affected its toxicity or efficacy. RTOG 0119 was a phase II randomized trial for this group of patients. Methods and Materials: RTOG RPA Class 2 patients with brain metastases were randomized to 20 mg of melatonin, given either in the morning (8-9 AM) or in the evening (8-9 PM). All patients received radiation therapy (30 Gy in 10 fractions) in the afternoon. Melatonin was continued until neurologic deterioration or death. The primary endpoint was overall survival time. Neurologic deterioration, as reflected by the Mini-Mental Status Examination, was also measured. Results: Neither of the randomized groups had survival distributions that differed significantly from the historic controls of patients treated with whole-brain radiotherapy. The median survivals of the morning and evening melatonin treatments were 3.4 and 2.8 months, while the RTOG historical control survival was 4.1 months. Conclusions: High-dose melatonin did not show any beneficial effect in this group of patients

  19. Primary treatment of acromegaly with high-dose lanreotide: a case series

    Directory of Open Access Journals (Sweden)

    Cordes Uwe

    2010-03-01

    Full Text Available Abstract Introduction The first-line treatment for acromegaly is transsphenoidal surgery. In approximately 50% of patients, however, a cure is not possible with surgery and alternatives are needed. Somatostatin analog therapy is the recommended first-line treatment in patients with such cases. Here we provide the first report of a high-dose lanreotide primary therapy in patients with acromegaly. Case presentation Six patients who were not suitable for surgery were given 60 mg of lanreotide (Autogel® every four weeks. All patients were German nationals and Caucasian. When the response of our patients was unsatisfactory, the dose was increased sequentially to 90 mg every four weeks, 120 mg every four weeks, 120 mg every three weeks and 180 mg every three weeks. Treatment duration was 12 to 24 months. In all cases, the lanreotide dose was 120 mg every 4 weeks or higher. In five of our patients, growth hormone (GH levels were successfully reduced (in three patients GH Tumor shrinkage or degeneration was observed in the five responding patients. No drug-related adverse events were noted. Conclusions These results suggest that lanreotide at high doses of 120 mg every four weeks or more is an effective first-line therapy for patients with acromegaly that surgery alone cannot treat.

  20. Androgen Deprivation Therapy Use in the Setting of High-dose Radiation Therapy and the Risk of Prostate Cancer–Specific Mortality Stratified by the Extent of Competing Mortality

    Energy Technology Data Exchange (ETDEWEB)

    Rose, Brent S., E-mail: brose44@gmail.com [Harvard Radiation Oncology Program, Brigham and Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Chen, Ming-Hui; Wu, Jing [Department of Statistics, University of Connecticut, Storrs, Connecticut (United States); Braccioforte, Michelle H.; Moran, Brian J. [Prostate Cancer Foundation of Chicago, Westmont, Illinois (United States); Doseretz, Daniel E.; Katin, Michael J.; Ross, Rudolf H.; Salenius, Sharon A. [21st Century Oncology, Inc, Fort Myers, Florida (United States); D' Amico, Anthony V. [Department of Radiation Oncology, Brigham and Women' s Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2016-11-15

    Purpose: The addition of androgen deprivation therapy (ADT) to radiation therapy (RT) is the standard of care for men with intermediate- and high-risk prostate cancer (PC). However, whether competing mortality (CM) affects the ability of ADT to improve, survival remains unanswered. Methods and Materials: We calculated a CM risk score using a Fine-Gray semiparametric model that included age and cardiometabolic comorbidities from a cohort of 17,669 men treated with high-dose RT with or without supplemental ADT for nonmetastatic PC. Fine and Gray competing risk regression analysis was used to assess whether ADT reduced the risk of PC-specific mortality for men with a low versus a high risk of CM among the 4550 patients within the intermediate- and high-risk cohort after adjustment for established PC prognostic factors, year of treatment, site, and ADT propensity score. Results: After a median follow-up of 8.4 years, 1065 men had died, 89 (8.36%) of PC. Among the men with a low CM score, ADT use was associated with a significant reduction in the risk of PC-specific mortality (adjusted hazard ratio 0.35, 95% confidence interval 0.14-0.87, P=.02) but was not for men with high CM (adjusted hazard ratio 1.33, 95% confidence interval 0.77-2.30, P=.30). Conclusions: Adding ADT to high-dose RT appears to be associated with decreased PC-specific mortality risk in men with a low but not a high CM score. These data should serve to heighten awareness about the importance of considering competing risks when determining whether to add ADT to RT for older men with intermediate- or high-risk PC.

  1. Androgen Deprivation Therapy Use in the Setting of High-dose Radiation Therapy and the Risk of Prostate Cancer–Specific Mortality Stratified by the Extent of Competing Mortality

    International Nuclear Information System (INIS)

    Rose, Brent S.; Chen, Ming-Hui; Wu, Jing; Braccioforte, Michelle H.; Moran, Brian J.; Doseretz, Daniel E.; Katin, Michael J.; Ross, Rudolf H.; Salenius, Sharon A.; D'Amico, Anthony V.

    2016-01-01

    Purpose: The addition of androgen deprivation therapy (ADT) to radiation therapy (RT) is the standard of care for men with intermediate- and high-risk prostate cancer (PC). However, whether competing mortality (CM) affects the ability of ADT to improve, survival remains unanswered. Methods and Materials: We calculated a CM risk score using a Fine-Gray semiparametric model that included age and cardiometabolic comorbidities from a cohort of 17,669 men treated with high-dose RT with or without supplemental ADT for nonmetastatic PC. Fine and Gray competing risk regression analysis was used to assess whether ADT reduced the risk of PC-specific mortality for men with a low versus a high risk of CM among the 4550 patients within the intermediate- and high-risk cohort after adjustment for established PC prognostic factors, year of treatment, site, and ADT propensity score. Results: After a median follow-up of 8.4 years, 1065 men had died, 89 (8.36%) of PC. Among the men with a low CM score, ADT use was associated with a significant reduction in the risk of PC-specific mortality (adjusted hazard ratio 0.35, 95% confidence interval 0.14-0.87, P=.02) but was not for men with high CM (adjusted hazard ratio 1.33, 95% confidence interval 0.77-2.30, P=.30). Conclusions: Adding ADT to high-dose RT appears to be associated with decreased PC-specific mortality risk in men with a low but not a high CM score. These data should serve to heighten awareness about the importance of considering competing risks when determining whether to add ADT to RT for older men with intermediate- or high-risk PC.

  2. High-dose myeloablative versus conventional low-dose radioimmunotherapy (RIT) of mantle cell lymphoma (MCL) with the chimeric anti-CD20 antibody C2B8

    International Nuclear Information System (INIS)

    Behr, T.M.; Gotthardt, M.; Schipperm, M.L.; Gratz, S.; Behe, M.P.; Brittinger, G.; Woermann, B.; Becker, W.

    2002-01-01

    CD20 has been used as target molecule for low-dose as well as high-dose, myeloablative RIT of B-cell NHL. MCL is an especially aggressive, prognostically unfavorable form of B-cell NHL. The aim of this study was to investigate whether high-dose, myeloablative RIT with the 131 I-labeled chimeric anti-CD20 antibody C2B8 (rituxan, Mabthera, Roche) may be therapeutically more effective than conventional low-dose therapy in MCL. A total of twelve patients with chemorefractory or relapsed mantle cell lymphoma were studied so far (all of them having relapsed after high-dose chemotherapy, seven of them combined with 12 Gy TBI). A diagnostic-dosimetric study was performed with 10 mCi of 131 I-C2B8 at a protein dose of 2.5 mg/kg. In case of splenic pooling, the protein dose was increased until a more 'favorable' biodistribution was obtained. Therapy was performed with conventional (30-75 mCi; n=4) or myeloablative activities (261-515 mCi; n=8) of 131 I-C2B8 at the previously optimized protein dose, aiming at whole-body doses of ≤ 0.8 Gy (for low-dose RIT) or lung doses of ≤ 27 Gy (for high-dose RIT). Clinical follow-up was obtained for up to 42 months. Overall, in 11 patients the 2.5 mg/kg protein dose was used, whereas in one patient with marked splenomegaly, 10 mg/kg were necessary to overcome the splenic antigenic sink. In the high-dose patients, non-hematologic toxicity was restricted to mild to moderate nausea, fever, transient bilirubin or liver enzyme elevations. Despite thyroid blocking, 6/8 high-dose (in contrast to 0/4 low-dose) patients developed hypothyroidism, requiring thyroxine substitution at 6-18 months after RIT. The response rate in the low-dose arm was only 1(PR)/4, whereas 7/8 high-dose patients experienced complete and the remainder a partial remission. 6 high-dose patients are still in CR (one of them relapsed locally at 3 months, one systemically at 26 months after RIT), and 7 are still alive for up to 42+ months. In contrast to low-dose therapy

  3. Graves' disease radioiodine-therapy: Choosing target absorbed doses for therapy planning

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, J., E-mail: j.willegaignon@gmail.com; Sapienza, M. T.; Coura-Filho, G. B.; Buchpiguel, C. A. [Cancer Institute of São Paulo State (ICESP), Clinical Hospital, School of Medicine, University of São Paulo, São Paulo 01246-000 (Brazil); Nuclear Medicine Service, Department of Radiology, School of Medicine, University of São Paulo, Sao Paulo 01246-000 (Brazil); Watanabe, T. [Nuclear Medicine Service, Department of Radiology, School of Medicine, University of São Paulo, São Paulo 01246-000 (Brazil); Traino, A. C. [Unit of Medical Physics, Azienda Ospedaliero-Universitaria Pisana, Pisa 56126 (Italy)

    2014-01-15

    Purpose: The precise determination of organ mass (m{sub th}) and total number of disintegrations within the thyroid gland (A{sup ~}) are essential for thyroid absorbed-dose calculations for radioiodine therapy. Nevertheless, these parameters may vary according to the method employed for their estimation, thus introducing uncertainty in the estimated thyroid absorbed dose and in any dose–response relationship derived using such estimates. In consideration of these points, thyroid absorbed doses for Graves’ disease (GD) treatment planning were calculated using different approaches to estimating the m{sub th} and the A{sup ~}. Methods: Fifty patients were included in the study. Thyroid{sup 131}I uptake measurements were performed at 2, 6, 24, 48, 96, and 220 h postadministration of a tracer activity in order to estimate the effective half-time (T{sub eff}) of {sup 131}I in the thyroid; the thyroid cumulated activity was then estimated using the T{sub eff} thus determined or, alternatively, calculated by numeric integration of the measured time-activity data. Thyroid mass was estimated by ultrasonography (USG) and scintigraphy (SCTG). Absorbed doses were calculated with the OLINDA/EXM software. The relationships between thyroid absorbed dose and therapy response were evaluated at 3 months and 1 year after therapy. Results: The average ratio (±1 standard deviation) betweenm{sub th} estimated by SCTG and USG was 1.74 (±0.64) and that between A{sup ~} obtained by T{sub eff} and the integration of measured activity in the gland was 1.71 (±0.14). These differences affect the calculated absorbed dose. Overall, therapeutic success, corresponding to induction of durable hypothyroidism or euthyroidism, was achieved in 72% of all patients at 3 months and in 90% at 1 year. A therapeutic success rate of at least 95% was found in the group of patients receiving doses of 200 Gy (p = 0.0483) and 330 Gy (p = 0.0131) when m{sub th} was measured by either USG or SCTG and A

  4. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  5. Quasi-VMAT in high-grade glioma radiation therapy

    International Nuclear Information System (INIS)

    Fadda, G.; Massazza, G.; Zucca, S.; Durzu, S.; Meleddu, G.; Possanzini, M.; Farace, P.

    2013-01-01

    Purpose: To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession. Patients and methods: This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2-3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1-3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose 95% and conformity index (CI) values in comparison to 3D-CRT (PTV 95% = 90.7 % vs. 82.0 %; CI = 0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV 95% = 94.4 %, CI = 0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV 95% = 88.5 % and 92.3 %, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT. Conclusion: These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example, which have limited departmental resources and are not equipped with systems capable of VMAT delivery. (orig.)

  6. Second Solid Cancers After Radiation Therapy: A Systematic Review of the Epidemiologic Studies of the Radiation Dose-Response Relationship

    Energy Technology Data Exchange (ETDEWEB)

    Berrington de Gonzalez, Amy, E-mail: berringtona@mail.nih.gov [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Gilbert, Ethel; Curtis, Rochelle; Inskip, Peter; Kleinerman, Ruth; Morton, Lindsay; Rajaraman, Preetha; Little, Mark P. [Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States)

    2013-06-01

    Rapid innovations in radiation therapy techniques have resulted in an urgent need for risk projection models for second cancer risks from high-dose radiation exposure, because direct observation of the late effects of newer treatments will require patient follow-up for a decade or more. However, the patterns of cancer risk after fractionated high-dose radiation are much less well understood than those after lower-dose exposures (0.1-5 Gy). In particular, there is uncertainty about the shape of the dose-response curve at high doses and about the magnitude of the second cancer risk per unit dose. We reviewed the available evidence from epidemiologic studies of second solid cancers in organs that received high-dose exposure (>5 Gy) from radiation therapy where dose-response curves were estimated from individual organ-specific doses. We included 28 eligible studies with 3434 second cancer patients across 11 second solid cancers. Overall, there was little evidence that the dose-response curve was nonlinear in the direction of a downturn in risk, even at organ doses of ≥60 Gy. Thyroid cancer was the only exception, with evidence of a downturn after 20 Gy. Generally the excess relative risk per Gray, taking account of age and sex, was 5 to 10 times lower than the risk from acute exposures of <2 Gy among the Japanese atomic bomb survivors. However, the magnitude of the reduction in risk varied according to the second cancer. The results of our review provide insights into radiation carcinogenesis from fractionated high-dose exposures and are generally consistent with current theoretical models. The results can be used to refine the development of second solid cancer risk projection models for novel radiation therapy techniques.

  7. Radiation Therapy Dose Escalation for Glioblastoma Multiforme in the Era of Temozolomide

    Energy Technology Data Exchange (ETDEWEB)

    Badiyan, Shahed N.; Markovina, Stephanie; Simpson, Joseph R.; Robinson, Clifford G.; DeWees, Todd [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States); Tran, David D.; Linette, Gerry [Division of Medical Oncology, Department of Medicine, Washington University School of Medicine, St. Louis, Missouri (United States); Jalalizadeh, Rohan [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States); Dacey, Ralph; Rich, Keith M.; Chicoine, Michael R.; Dowling, Joshua L.; Leuthardt, Eric C.; Zipfel, Gregory J.; Kim, Albert H. [Department of Neurosurgery, Washington University School of Medicine, St. Louis, Missouri (United States); Huang, Jiayi, E-mail: jhuang@radonc.wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri (United States)

    2014-11-15

    Purpose: To review clinical outcomes of moderate dose escalation using high-dose radiation therapy (HDRT) in the setting of concurrent temozolomide (TMZ) in patients with newly diagnosed glioblastoma multiforme (GBM), compared with standard-dose radiation therapy (SDRT). Methods and Materials: Adult patients aged <70 years with biopsy-proven GBM were treated with SDRT (60 Gy at 2 Gy per fraction) or with HDRT (>60 Gy) and TMZ from 2000 to 2012. Biological equivalent dose at 2-Gy fractions was calculated for the HDRT assuming an α/β ratio of 5.6 for GBM. Results: Eighty-one patients received SDRT, and 128 patients received HDRT with a median (range) biological equivalent dose at 2-Gy fractions of 64 Gy (61-76 Gy). Overall median follow-up time was 1.10 years, and for living patients it was 2.97 years. Actuarial 5-year overall survival (OS) and progression-free survival (PFS) rates for patients that received HDRT versus SDRT were 12.4% versus 13.2% (P=.71), and 5.6% versus 4.1% (P=.54), respectively. Age (P=.001) and gross total/near-total resection (GTR/NTR) (P=.001) were significantly associated with PFS on multivariate analysis. Younger age (P<.0001), GTR/NTR (P<.0001), and Karnofsky performance status ≥80 (P=.001) were associated with improved OS. On subset analyses, HDRT failed to improve PFS or OS for those aged <50 years or those who had GTR/NTR. Conclusion: Moderate radiation therapy dose escalation above 60 Gy with concurrent TMZ does not seem to improve clinical outcomes for patients with GBM.

  8. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  9. Dose perturbation effect of metallic spinal implants in proton beam therapy.

    Science.gov (United States)

    Jia, Yingcui; Zhao, Li; Cheng, Chee-Wai; McDonald, Mark W; Das, Indra J

    2015-09-08

    The purpose of this study was to investigate the effect of dose perturbations for two metallic spinal screw implants in proton beam therapy in the perpendicular and parallel beam geometry. A 5.5 mm (diameter) by 45 mm (length) stainless steel (SS) screw and a 5.5 mm by 35 mm titanium (Ti) screw commonly used for spinal fixation were CT-scanned in a hybrid phantom of water and solid water. The CT data were processed with an orthopedic metal artifact reduction (O-MAR) algorithm. Treatment plans were generated for each metal screw with a proton beam oriented, first parallel and then perpendicular, to the longitudinal axis of the screw. The calculated dose profiles were compared with measured results from a plane-parallel ion chamber and Gafchromic EBT2 films. For the perpendicular setup, the measured dose immediately downstream from the screw exhibited dose enhancement up to 12% for SS and 8% for Ti, respectively, but such dose perturbation was not observed outside the lateral edges of the screws. The TPS showed 5% and 2% dose reductions immediately at the interface for the SS nd Ti screws, respectively, and up to 9% dose enhancements within 1 cm outside of the lateral edges of the screws. The measured dose enhancement was only observed within 5 mm from the interface along the beam path. At deeper depths, the lateral dose profiles appeared to be similar between the measurement and TPS, with dose reduction in the screw shadow region and dose enhancement within 1-2 cm outside of the lateral edges of the metals. For the parallel setup, no significant dose perturbation was detected at lateral distance beyond 3 mm away from both screws. Significant dose discrepancies exist between TPS calculations and ion chamber and film measurements in close proximity of high-Z inhomogeneities. The observed dose enhancement effect with proton therapy is not correctly modeled by TPS. An extra measure of caution should be taken when evaluating dosimetry with spinal metallic implants.

  10. Results of high intensity afterloading irradiation with 192 iridium in the therapy of genital tumors in women under different dose rates, fractionations and total doses in comparison with conventional radium contact irradiation. Ergebnisse der High-Intensity-Afterloadingbestrahlung mit 192 Iridium in der Therapie von Genitaltumoren der Frau unter verschiedenen Dosisleistungen, Fraktionierungen und Gesamtdosen im Vergleich mit konventioneller Radiumkontaktbestrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Giers, G

    1986-05-07

    In comparison to conventional radium therapy are to be evaluated the results of the high intensity afterloading technique with the help of the parameters survial rate and complication rate. Thereby were included in the examination 4 documentations of results (collum, cervix stump, corpus and vaginal carcinoma) with altogether 742 patients with 2806 single irradiations and an evaluation of the therapy after several modifications of the therapy schemes. The 5-year survival rate was in the case of collum carcinoma: 68.4%, cervix stump: 50%, corpus carcinoma: 76%, and vaginal carcinoma: 66.6%. The corresponding 3-year survival rates were: 74.2%, 80%, 84% and 70% with primary irradiation. Only with cervix stump carcinoma were the values for post-operative irradiation. The description of the irradiation results showed, that with the changing of the fractionation mode and the dose level in collum and corpus carcinoma the irreversible complications as an expression of the success of a new therapy were reduced. The for now best suited therapy schema (fractionation and dosing) are described. (TRV).

  11. Estimation dose of secondary neutrons in proton therapy

    International Nuclear Information System (INIS)

    Urban, T.

    2014-01-01

    Most of proton therapy centers for cancer treatment are still based on the passive scattering, in some of them there is system of the active scanning installed as well. The aim of this study is to compare secondary neutron doses in and around target volumes in proton therapy for both treatment techniques and for different energies and profile of incident proton beam. The proton induced neutrons have been simulated in the very simple geometry of tissue equivalent phantom (imitate the patient) and scattering and scanning nozzle, respectively. In simulations of the scattering nozzle, different types of scattering filters and brass collimators have been used as well. 3D map of neutron doses in and around the chosen/potential target volume in the phantom/patient have been evaluated and compared in the context of the dose deposited in the target volume. Finally, the simulation results have been compared with published data. (author)

  12. Continued Benefit to Androgen Deprivation Therapy for Prostate Cancer Patients Treated With Dose-Escalated Radiation Therapy Across Multiple Definitions of High-Risk Disease

    International Nuclear Information System (INIS)

    Stenmark, Matthew H.; Blas, Kevin; Halverson, Schuyler; Sandler, Howard M.; Feng, Felix Y.; Hamstra, Daniel A.

    2011-01-01

    Purpose: To analyze prognostic factors in patients with high-risk prostate cancer treated with dose-escalated external-beam radiation therapy (EBRT) and androgen deprivation (ADT). Methods and Materials: Between 1998 and 2008 at University of Michigan Medical Center, 718 men were consecutively treated with EBRT to at least 75 Gy. Seven definitions of high-risk prostate cancer, applying to 11–33% of patients, were evaluated. Biochemical failure (BF), salvage ADT use, metastatic progression, and prostate cancer–specific mortality (PCSM) were estimated by the Kaplan-Meier method and Cox proportional hazards regression. Results: Each high-risk definition was associated with increased BF (hazard ratio [HR] 2.8–3.9, p < 0.0001), salvage ADT use (HR 3.9–6.3, p < 0.0001), metastasis (HR 3.7–6.6, p < 0.0001), and PCSM (HR 3.7–16.2, p < 0.0001). Furthermore, an increasing number of high-risk features predicted worse outcome. Adjuvant ADT yielded significant reductions in both metastases (HR 0.19–0.38, p < 0.001) and PCSM (HR 0.38–0.50, p < 0.05) for all high-risk definitions (with the exception of clinical Stage T3–4 disease) but improved BF only for those with elevated Gleason scores (p < 0.03, HR 0.25–0.48). When treated with ADT and dose-escalated EBRT, patients with Gleason scores 8 to 10, without other high-risk features, had 8-year freedom from BF of 74%, freedom from distant metastases of 93%, and cause-specific survival of 92%, with salvage ADT used in 16% of patients. Conclusion: Adjuvant ADT results in a significant improvement in clinical progression and PCSM across multiple definitions of high-risk disease even with dose-escalated EBRT. There is a subset of patients, characterized by multiple high-risk features or the presence of Gleason Pattern 5, who remain at significant risk for metastasis and PCSM despite current treatment.

  13. Dose-Escalated Stereotactic Body Radiation Therapy for Patients With Intermediate- and High-Risk Prostate Cancer: Initial Dosimetry Analysis and Patient Outcomes

    International Nuclear Information System (INIS)

    Kotecha, Rupesh; Djemil, Toufik; Tendulkar, Rahul D.; Reddy, Chandana A.; Thousand, Richard A.; Vassil, Andrew; Stovsky, Mark; Berglund, Ryan K.; Klein, Eric A.; Stephans, Kevin L.

    2016-01-01

    Purpose: To report the short-term clinical outcomes and acute and late treatment-related genitourinary (GU) and gastrointestinal (GI) toxicities in patients with intermediate- and high-risk prostate cancer treated with dose-escalated stereotactic body radiation therapy (SBRT). Methods and Materials: Between 2011 and 2014, 24 patients with prostate cancer were treated with SBRT to the prostate gland and proximal seminal vesicles. A high-dose avoidance zone (HDAZ) was created by a 3-mm expansion around the rectum, urethra, and bladder. Patients were treated to a minimum dose of 36.25 Gy in 5 fractions, with a simultaneous dose escalation to a dose of 50 Gy to the target volume away from the HDAZ. Acute and late GU and GI toxicity outcomes were measured according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 4. Results: The median follow-up was 25 months (range, 18-45 months). Nine patients (38%) experienced an acute grade 2 GU toxicity, which was medically managed, and no patients experienced an acute grade 2 GI toxicity. Two patients (8%) experienced late grade 2 GU toxicity, and 2 patients (8%) experienced late grade 2 GI toxicity. No acute or late grade ≥3 GU or GI toxicities were observed. The 24-month prostate-specific antigen relapse-free survival outcome for all patients was 95.8% (95% confidence interval 75.6%-99.4%), and both biochemical failures occurred in patients with high-risk disease. All patients are currently alive at the time of this analysis and continue to be followed. Conclusions: A heterogeneous prostate SBRT planning technique with differential treatment volumes (low dose: 36.25 Gy; and high dose: 50 Gy) with an HDAZ provides a safe method of dose escalation. Favorable rates of biochemical control and acceptably low rates of acute and long-term GU and GI toxicity can be achieved in patients with intermediate- and high-risk prostate cancer treated with SBRT.

  14. Dose-Escalated Stereotactic Body Radiation Therapy for Patients With Intermediate- and High-Risk Prostate Cancer: Initial Dosimetry Analysis and Patient Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Kotecha, Rupesh; Djemil, Toufik; Tendulkar, Rahul D.; Reddy, Chandana A.; Thousand, Richard A.; Vassil, Andrew [Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Stovsky, Mark; Berglund, Ryan K.; Klein, Eric A. [Department of Urology, Glickman Urological and Kidney Institute, Cleveland Clinic, Cleveland, Ohio (United States); Stephans, Kevin L., E-mail: stephak@ccf.org [Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States)

    2016-07-01

    Purpose: To report the short-term clinical outcomes and acute and late treatment-related genitourinary (GU) and gastrointestinal (GI) toxicities in patients with intermediate- and high-risk prostate cancer treated with dose-escalated stereotactic body radiation therapy (SBRT). Methods and Materials: Between 2011 and 2014, 24 patients with prostate cancer were treated with SBRT to the prostate gland and proximal seminal vesicles. A high-dose avoidance zone (HDAZ) was created by a 3-mm expansion around the rectum, urethra, and bladder. Patients were treated to a minimum dose of 36.25 Gy in 5 fractions, with a simultaneous dose escalation to a dose of 50 Gy to the target volume away from the HDAZ. Acute and late GU and GI toxicity outcomes were measured according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 4. Results: The median follow-up was 25 months (range, 18-45 months). Nine patients (38%) experienced an acute grade 2 GU toxicity, which was medically managed, and no patients experienced an acute grade 2 GI toxicity. Two patients (8%) experienced late grade 2 GU toxicity, and 2 patients (8%) experienced late grade 2 GI toxicity. No acute or late grade ≥3 GU or GI toxicities were observed. The 24-month prostate-specific antigen relapse-free survival outcome for all patients was 95.8% (95% confidence interval 75.6%-99.4%), and both biochemical failures occurred in patients with high-risk disease. All patients are currently alive at the time of this analysis and continue to be followed. Conclusions: A heterogeneous prostate SBRT planning technique with differential treatment volumes (low dose: 36.25 Gy; and high dose: 50 Gy) with an HDAZ provides a safe method of dose escalation. Favorable rates of biochemical control and acceptably low rates of acute and long-term GU and GI toxicity can be achieved in patients with intermediate- and high-risk prostate cancer treated with SBRT.

  15. High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference.

    Science.gov (United States)

    Piketty, Marie-Liesse; Prie, Dominique; Sedel, Frederic; Bernard, Delphine; Hercend, Claude; Chanson, Philippe; Souberbielle, Jean-Claude

    2017-05-01

    High-dose biotin therapy is beneficial in progressive multiple sclerosis (MS) and is expected to be adopted by a large number of patients. Biotin therapy leads to analytical interference in many immunoassays that utilize streptavidin-biotin capture techniques, yielding skewed results that can mimic various endocrine disorders. We aimed at exploring this interference, to be able to remove biotin and avoid misleading results. We measured free triiodothyronine (fT3), free thyroxine (fT4), thyroid-stimulating hormone (TSH), parathyroid homrone (PTH), 25-hydroxyvitamin D (25OHD), follicle-stimulating hormone (FSH), luteinizing hormone (LH), prolactin, C-peptide, cortisol (Roche Diagnostics assays), biotin and its main metabolites (liquid chromatography tandem mass spectrometry) in 23 plasmas from MS patients and healthy volunteers receiving high-dose biotin, and in 39 biotin-unsupplemented patients, before and after a simple procedure (designated N5) designed to remove biotin by means of streptavidin-coated microparticles. We also assayed fT4, TSH and PTH in the 23 high-biotin plasmas using assays not employing streptavidin-biotin binding. The biotin concentration ranged from 31.7 to 1160 µg/L in the 23 high-biotin plasmas samples. After the N5 protocol, the biotin concentration was below the detection limit in all but two samples (8.3 and 27.6 μg/L). Most hormones results were abnormal, but normalized after N5. All results with the alternative methods were normal except two slight PTH elevations. In the 39 biotin-unsupplemented patients, the N5 protocol did not affect the results for any of the hormones, apart from an 8.4% decrease in PTH. We confirm that most streptavidin-biotin hormone immunoassays are affected by high biotin concentrations, leading to a risk of misdiagnosis. Our simple neutralization method efficiently suppresses biotin interference.

  16. Dose and Fractionation in Radiation Therapy of Curative Intent for Non-Small Cell Lung Cancer: Meta-Analysis of Randomized Trials

    Energy Technology Data Exchange (ETDEWEB)

    Ramroth, Johanna; Cutter, David J.; Darby, Sarah C. [Nuffield Department of Population Health, University of Oxford, Oxford, Oxfordshire (United Kingdom); Higgins, Geoff S. [Department of Oncology, University of Oxford, Oxford, Oxfordshire (United Kingdom); McGale, Paul [Nuffield Department of Population Health, University of Oxford, Oxford, Oxfordshire (United Kingdom); Partridge, Mike [CRUK/MRC Oxford Institute for Radiation Oncology, Oxford, Oxfordshire (United Kingdom); Taylor, Carolyn W., E-mail: carolyn.taylor@ndph.ox.ac.uk [Nuffield Department of Population Health, University of Oxford, Oxford, Oxfordshire (United Kingdom)

    2016-11-15

    Purpose: The optimum dose and fractionation in radiation therapy of curative intent for non-small cell lung cancer remains uncertain. We undertook a published data meta-analysis of randomized trials to examine whether radiation therapy regimens with higher time-corrected biologically equivalent doses resulted in longer survival, either when given alone or when given with chemotherapy. Methods and Materials: Eligible studies were randomized comparisons of 2 or more radiation therapy regimens, with other treatments identical. Median survival ratios were calculated for each comparison and pooled. Results: 3795 patients in 25 randomized comparisons of radiation therapy dose were studied. The median survival ratio, higher versus lower corrected dose, was 1.13 (95% confidence interval [CI] 1.04-1.22) when radiation therapy was given alone and 0.83 (95% CI 0.71-0.97) when it was given with concurrent chemotherapy (P for difference=.001). In comparisons of radiation therapy given alone, the survival benefit increased with increasing dose difference between randomized treatment arms (P for trend=.004). The benefit increased with increasing dose in the lower-dose arm (P for trend=.01) without reaching a level beyond which no further survival benefit was achieved. The survival benefit did not differ significantly between randomized comparisons where the higher-dose arm was hyperfractionated and those where it was not. There was heterogeneity in the median survival ratio by geographic region (P<.001), average age at randomization (P<.001), and year trial started (P for trend=.004), but not for proportion of patients with squamous cell carcinoma (P=.2). Conclusions: In trials with concurrent chemotherapy, higher radiation therapy doses resulted in poorer survival, possibly caused, at least in part, by high levels of toxicity. Where radiation therapy was given without chemotherapy, progressively higher radiation therapy doses resulted in progressively longer survival, and no

  17. Dose and Fractionation in Radiation Therapy of Curative Intent for Non-Small Cell Lung Cancer: Meta-Analysis of Randomized Trials

    International Nuclear Information System (INIS)

    Ramroth, Johanna; Cutter, David J.; Darby, Sarah C.; Higgins, Geoff S.; McGale, Paul; Partridge, Mike; Taylor, Carolyn W.

    2016-01-01

    Purpose: The optimum dose and fractionation in radiation therapy of curative intent for non-small cell lung cancer remains uncertain. We undertook a published data meta-analysis of randomized trials to examine whether radiation therapy regimens with higher time-corrected biologically equivalent doses resulted in longer survival, either when given alone or when given with chemotherapy. Methods and Materials: Eligible studies were randomized comparisons of 2 or more radiation therapy regimens, with other treatments identical. Median survival ratios were calculated for each comparison and pooled. Results: 3795 patients in 25 randomized comparisons of radiation therapy dose were studied. The median survival ratio, higher versus lower corrected dose, was 1.13 (95% confidence interval [CI] 1.04-1.22) when radiation therapy was given alone and 0.83 (95% CI 0.71-0.97) when it was given with concurrent chemotherapy (P for difference=.001). In comparisons of radiation therapy given alone, the survival benefit increased with increasing dose difference between randomized treatment arms (P for trend=.004). The benefit increased with increasing dose in the lower-dose arm (P for trend=.01) without reaching a level beyond which no further survival benefit was achieved. The survival benefit did not differ significantly between randomized comparisons where the higher-dose arm was hyperfractionated and those where it was not. There was heterogeneity in the median survival ratio by geographic region (P<.001), average age at randomization (P<.001), and year trial started (P for trend=.004), but not for proportion of patients with squamous cell carcinoma (P=.2). Conclusions: In trials with concurrent chemotherapy, higher radiation therapy doses resulted in poorer survival, possibly caused, at least in part, by high levels of toxicity. Where radiation therapy was given without chemotherapy, progressively higher radiation therapy doses resulted in progressively longer survival, and no

  18. Safety of high-dose daptomycin in patients with severe renal impairment

    Directory of Open Access Journals (Sweden)

    Tai CH

    2018-03-01

    Full Text Available Chih-Hsun Tai,1 Chi-Hao Shao,2 Chen-You Chen,2 Shu-Wen Lin,1–3 Chien-Chih Wu1,2 1Department of Pharmacy, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan; 2School of Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan; 3Graduate Institute of Clinical Pharmacy, College of Medicine, National Taiwan University, Taipei, Taiwan Background: Treatment options are limited for infections due to multidrug-resistant Gram-positive pathogens. Daptomycin is a lipopeptide antibiotic with concentration-dependent killing characteristic and dose-dependent post-antibiotic effect. To achieve optimized pharmacodynamic effect, some experts advocated using a high dose of daptomycin (≥9 mg/kg for severe infections. However, the safety of high-dose therapy in patients with renal impairment remains unknown. This study was aimed to evaluate the safety of daptomycin in patients with severe renal impairment. Methods: This was a retrospective study performed by reviewing electronic medical records. Patients with severe renal impairment who were treated with daptomycin in a tertiary teaching hospital between January 1, 2013, and June 30, 2016, were included for evaluation. The incidence rates of creatine kinase (CK elevation between high-dose (≥9 mg/kg and standard-dose (<9 mg/kg groups were compared. Results: Overall, 164 patients met the inclusion criteria, and 114 (69.5% of them were on renal replacement therapy. Vancomycin-resistant enterococci were the most common pathogens (61.3% of the patients with documented pathogens. The treatment success rate was 51.6% in the 91 patients with bacteremia. The average dose of daptomycin was 8.0±2.3 mg/kg, and 37 (22.6% patients received ≥9 mg/kg. CK levels were followed in 108 (65.9% patients. Significantly higher incidence of CK elevation was found in the high-dose group compared with that in the standard-dose group (10.8% vs 1.6%, P<0.05. Moreover

  19. Increasing Use of Dose-Escalated External Beam Radiation Therapy for Men With Nonmetastatic Prostate Cancer

    International Nuclear Information System (INIS)

    Swisher-McClure, Samuel; Mitra, Nandita; Woo, Kaitlin; Smaldone, Marc; Uzzo, Robert; Bekelman, Justin E.

    2014-01-01

    Purpose: To examine recent practice patterns, using a large national cancer registry, to understand the extent to which dose-escalated external beam radiation therapy (EBRT) has been incorporated into routine clinical practice for men with prostate cancer. Methods and Materials: We conducted a retrospective observational cohort study using the National Cancer Data Base, a nationwide oncology outcomes database in the United States. We identified 98,755 men diagnosed with nonmetastatic prostate cancer between 2006 and 2011 who received definitive EBRT and classified patients into National Comprehensive Cancer Network (NCCN) risk groups. We defined dose-escalated EBRT as total prescribed dose of ≥75.6 Gy. Using multivariable logistic regression, we examined the association of patient, clinical, and demographic characteristics with the use of dose-escalated EBRT. Results: Overall, 81.6% of men received dose-escalated EBRT during the study period. The use of dose-escalated EBRT did not vary substantially by NCCN risk group. Use of dose-escalated EBRT increased from 70.7% of patients receiving treatment in 2006 to 89.8% of patients receiving treatment in 2011. On multivariable analysis, year of diagnosis and use of intensity modulated radiation therapy were significantly associated with receipt of dose-escalated EBRT. Conclusions: Our study results indicate that dose-escalated EBRT has been widely adopted by radiation oncologists treating prostate cancer in the United States. The proportion of patients receiving dose-escalated EBRT increased nearly 20% between 2006 and 2011. We observed high utilization rates of dose-escalated EBRT within all disease risk groups. Adoption of intensity modulated radiation therapy was strongly associated with use of dose-escalated treatment

  20. Can radiation therapy treatment planning system accurately predict surface doses in postmastectomy radiation therapy patients?

    International Nuclear Information System (INIS)

    Wong, Sharon; Back, Michael; Tan, Poh Wee; Lee, Khai Mun; Baggarley, Shaun; Lu, Jaide Jay

    2012-01-01

    Skin doses have been an important factor in the dose prescription for breast radiotherapy. Recent advances in radiotherapy treatment techniques, such as intensity-modulated radiation therapy (IMRT) and new treatment schemes such as hypofractionated breast therapy have made the precise determination of the surface dose necessary. Detailed information of the dose at various depths of the skin is also critical in designing new treatment strategies. The purpose of this work was to assess the accuracy of surface dose calculation by a clinically used treatment planning system and those measured by thermoluminescence dosimeters (TLDs) in a customized chest wall phantom. This study involved the construction of a chest wall phantom for skin dose assessment. Seven TLDs were distributed throughout each right chest wall phantom to give adequate representation of measured radiation doses. Point doses from the CMS Xio® treatment planning system (TPS) were calculated for each relevant TLD positions and results correlated. There were no significant difference between measured absorbed dose by TLD and calculated doses by the TPS (p > 0.05 (1-tailed). Dose accuracy of up to 2.21% was found. The deviations from the calculated absorbed doses were overall larger (3.4%) when wedges and bolus were used. 3D radiotherapy TPS is a useful and accurate tool to assess the accuracy of surface dose. Our studies have shown that radiation treatment accuracy expressed as a comparison between calculated doses (by TPS) and measured doses (by TLD dosimetry) can be accurately predicted for tangential treatment of the chest wall after mastectomy.

  1. Estudio experimental de la eficacia de meropenem y rifampicina en el tratamiento de la meningitis neumocócica sensible y resistente a betalactámicos

    OpenAIRE

    Force Sanmartín, Enriqueta

    2008-01-01

    La meningitis neumocócica es una enfermedad grave con elevada morbimortalidad y su tratamiento constituye un problema no completamente resuelto desde la aparición en todo el mundo de resistencias a penicilina y cefalosporinas. Meropenem es un carbapenémico que tiene una buena actividad in vitro frente a los principales patógenos que causan meningitis. El clásico modelo de meningitis en el conejo puede no ser adecuado para estudiar meropenem por la facilidad en hidrolizar la Dehidropeptidasa I...

  2. Functional results of radioiodine therapy with a 300-GY absorbed dose in Graves' disease

    International Nuclear Information System (INIS)

    Willemsen, U.F.; Knesewitsch, P.; Kreisig, T.; Pickardt, C.R.; Kirsch, C.M.

    1993-01-01

    The aim of this study was to assess the results of high-dose radioiodine therapy given to 43 patients with recurrent hyperthyroidism due to Graves' disease between 1986 and 1992. We chose an intrathyroidal absorbed dose of 300 Gy and determined the applied activity individually, which ranged from 240 to 3120 MBq with a median of 752 MBq. Hperthyroidism was eliminated in 86% of cases after 3 months and in 100% after 12 months. No patient required a second radioiodine treatment. The incidnece of hyperthyroidism was 63% after 3 months and 93% after 18 months. Neither the pretherapeutic thyroid-stimulating immunoglobulin level nor the degree of co-existing endocrine ophthalmopathy was correlated with the time at which hypothyroidism developed. Patients with previous radioiodine therapy developed hypothyroidism earlier than patients with previous thyroid surgery. The results show that ablative radioiodine therapy with a 300-Gy absorbed dose is a very effective treatment of hyperthyroidism in Graves' disease, but it should be restricted to patients with recurrent hyperthyroidism combined with severe co-existing disorders or episodes of unfavourable reactions to antithyroid drugs. (orig.)

  3. Causes of Mortality After Dose-Escalated Radiation Therapy and Androgen Deprivation for High-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    Tendulkar, Rahul D.; Hunter, Grant K.; Reddy, Chandana A.; Stephans, Kevin L.; Ciezki, Jay P.; Abdel-Wahab, May; Stephenson, Andrew J.; Klein, Eric A.; Mahadevan, Arul; Kupelian, Patrick A.

    2013-01-01

    Purpose: Men with high-risk prostate cancer have other competing causes of mortality; however, current risk stratification schema do not account for comorbidities. We aim to identify the causes of death and factors predictive for mortality in this population. Methods and Materials: A total of 660 patients with high-risk prostate cancer were treated with definitive high-dose external beam radiation therapy (≥74 Gy) and androgen deprivation (AD) between 1996 and 2009 at a single institution. Cox proportional hazards regression analysis was conducted to determine factors predictive of survival. Results: The median radiation dose was 78 Gy, median duration of AD was 6 months, and median follow-up was 74 months. The 10-year overall survival (OS) was 60.6%. Prostate cancer was the leading single cause of death, with 10-year mortality of 14.1% (95% CI 10.7-17.6), compared with other cancers (8.4%, 95% CI 5.7-11.1), cardiovascular disease (7.3%, 95% CI 4.7-9.9), and all other causes (10.4%, 95% CI 7.2-13.6). On multivariate analysis, older age (HR 1.55, P=.002) and Charlson comorbidity index score (CS) ≥1 (HR 2.20, P<.0001) were significant factors predictive of OS, whereas Gleason score, T stage, prostate-specific antigen, duration of AD, radiation dose, smoking history, and body mass index were not. Men younger than 70 years of age with CS = 0 were more likely to die of prostate cancer than any other cause, whereas older men or those with CS ≥1 more commonly suffered non-prostate cancer death. The cumulative incidences of prostate cancer-specific mortality were similar regardless of age or comorbidities (P=.60). Conclusions: Men with high-risk prostate cancer are more likely to die of causes other than prostate cancer, except for the subgroup of men younger than 70 years of age without comorbidities. Only older age and presence of comorbidities significantly predicted for OS, whereas prostate cancer- and treatment-related factors did not

  4. The evaluation of lens absorbed dose according to the optimold for whole brain radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yong Mo; Park, Byoung Suk; Ahn, Jong Ho; Song, Ki Won [Dept. of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-15

    In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made up to 5 mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. When there was the Optimold mask in the eyeball part, it was measured at 10.2cGy ± 1.5 in the simulation therapy, and at 24.8cGy ± 2.7 in the treatment, and when the Optimold mask was removed in the eye part, it was measured at 12.9cGy ± 2.2 in the simulation therapy, and at 17.6cGy ± 1.5 in the treatment. In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3cGy in the simulation therapy and was reduced approximately 7cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause

  5. The evaluation of lens absorbed dose according to the optimold for whole brain radiation therapy

    International Nuclear Information System (INIS)

    Yang, Yong Mo; Park, Byoung Suk; Ahn, Jong Ho; Song, Ki Won

    2014-01-01

    In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made up to 5 mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. When there was the Optimold mask in the eyeball part, it was measured at 10.2cGy ± 1.5 in the simulation therapy, and at 24.8cGy ± 2.7 in the treatment, and when the Optimold mask was removed in the eye part, it was measured at 12.9cGy ± 2.2 in the simulation therapy, and at 17.6cGy ± 1.5 in the treatment. In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3cGy in the simulation therapy and was reduced approximately 7cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause

  6. Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy

    International Nuclear Information System (INIS)

    Hälg, Roger A.; Besserer, Jürgen; Schneider, Uwe

    2012-01-01

    Purpose: The full benefit of the increased precision of contemporary treatment techniques can only be exploited if the accuracy of the patient positioning is guaranteed. Therefore, more and more imaging modalities are used in the process of the patient setup in clinical routine of radiation therapy. The improved accuracy in patient positioning, however, results in additional dose contributions to the integral patient dose. To quantify this, absorbed dose measurements from typical imaging procedures involved in an image-guided radiation therapy treatment were measured in an anthropomorphic phantom for a complete course of treatment. The experimental setup, including the measurement positions in the phantom, was exactly the same as in a preceding study of radiotherapy stray dose measurements. This allows a direct combination of imaging dose distributions with the therapy dose distribution. Methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The dose distributions from imaging devices used with treatment machines from the manufacturers Accuray, Elekta, Siemens, and Varian and from computed tomography scanners from GE Healthcare were determined and the resulting effective dose was calculated. The list of investigated imaging techniques consisted of cone beam computed tomography (kilo- and megavoltage), megavoltage fan beam computed tomography, kilo- and megavoltage planar imaging, planning computed tomography with and without gating methods and planar scout views. Results: A conventional 3D planning CT resulted in an effective dose additional to the treatment stray dose of less than 1 mSv outside of the treated volume, whereas a 4D planning CT resulted in a 10 times larger dose. For a daily setup of the patient with two planar kilovoltage images or with a fan beam CT at the TomoTherapy unit, an additional effective dose outside of the treated volume of less than 0.4 mSv and 1

  7. Statin dose reduction with complementary diet therapy: A pilot study of personalized medicine

    Directory of Open Access Journals (Sweden)

    Bianca Scolaro

    2018-05-01

    Full Text Available Objective: Statin intolerance, whether real or perceived, is a growing issue in clinical practice. Our aim was to evaluate the effects of reduced-dose statin therapy complemented with nutraceuticals. Methods: First phase: Initially, 53 type 2 diabetic statin-treated patients received a supplementation with fish oil (1.7 g EPA + DHA/day, chocolate containing plant sterols (2.2 g/day, and green tea (two sachets/day for 6 weeks. Second phase: “Good responders” to supplementation were identified after multivariate analysis (n = 10, and recruited for a pilot protocol of statin dose reduction. “Good responders” were then provided with supplementation for 12 weeks: standard statin therapy was kept during the first 6 weeks and reduced by 50% from weeks 6–12. Results: First phase: After 6 weeks of supplementation, plasma LDL-C (−13.7% ± 3.7, P = .002 and C-reactive protein (−35.5% ± 5.9, P = .03 were reduced. Analysis of lathosterol and campesterol in plasma suggested that intensity of LDL-C reduction was influenced by cholesterol absorption rate rather than its synthesis. Second phase: no difference was observed for plasma lipids, inflammation, cholesterol efflux capacity, or HDL particles after statin dose reduction when compared to standard therapy. Conclusions: Although limited by the small sample size, our study demonstrates the potential for a new therapeutic approach combining lower statin dose and specific dietary compounds. Further studies should elucidate “good responders” profile as a tool for personalized medicine. This may be particularly helpful in the many patients with or at risk for CVD who cannot tolerate high dose statin therapy. Trial registration: ClinicalTrials.gov, NCT02732223. Keywords: Atherosclerosis, Omega-3 fatty acids, Plant sterols, Polyphenols, Responders

  8. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer.

    Science.gov (United States)

    Martinez, Alvaro A; Gustafson, Gary; Gonzalez, José; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-06-01

    To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level >or=10.0 ng/mL, Gleason score >or=7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause-specific survival with higher doses. These results, coupled with the low risk of complications, the advantage of not being radioactive after implantation, and the real-time interactive planning, define a new standard for treatment.

  9. Pharmacokinetics of and short-term virologic response to low-dose 400-milligram once-daily raltegravir maintenance therapy.

    NARCIS (Netherlands)

    Ananworanich, J.; Gorowara, M.; Avihingsanon, A.; Kerr, S.J.; Heesch, N. van; Khongpetch, C.; Uanithirat, A.; Hill, A.; Ruxrungtham, K.; Burger, D.M.

    2012-01-01

    Because studies showed similar viral suppression with lower raltegravir doses and because Asians usually have high antiretroviral concentrations, we explored low-dose raltegravir therapy in Thais. Nineteen adults on raltegravir at 400 mg twice daily (BID) with HIV RNA loads of <50 copies/ml were

  10. Estimation of four-dimensional dose distribution using electronic portal imaging device in radiation therapy

    International Nuclear Information System (INIS)

    Mizoguchi, Asumi; Arimura, Hidetaka; Shioyama, Yoshiyuki

    2013-01-01

    We are developing a method to evaluate four-dimensional radiation dose distribution in a patient body based upon the animated image of EPID (electronic portal imaging device) which is an image of beam-direction at the irradiation. In the first place, we have obtained the image of the dose which is emitted from patient body at therapy planning using therapy planning CT image and dose evaluation algorism. In the second place, we have estimated the emission dose image at the irradiation using EPID animated image which is obtained at the irradiation. In the third place, we have got an affine transformation matrix including respiratory movement in the body by performing linear registration on the emission dose image at therapy planning to get the one at the irradiation. In the fourth place, we have applied the affine transformation matrix on the therapy planning CT image and estimated the CT image 'at irradiation'. Finally we have evaluated four-dimensional dose distribution by calculating dose distribution in the CT image 'at irradiation' which has been estimated for each frame of the EPID animated-image. This scheme may be useful for evaluating therapy results and risk management. (author)

  11. Quasi-VMAT in high-grade glioma radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fadda, G.; Massazza, G.; Zucca, S.; Durzu, S.; Meleddu, G.; Possanzini, M.; Farace, P. [Regional Oncological Hospital, Cagliari (Italy). Dept. of Radio-Oncology

    2013-05-15

    Purpose: To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession. Patients and methods: This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2-3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1-3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose < 54 Gy) for a virtual OAR in the form of a 0.5 cm ring around the PTV was investigated. Results: The qVMAT method gave rise to significantly improved PTV{sub 95%} and conformity index (CI) values in comparison to 3D-CRT (PTV{sub 95%} = 90.7 % vs. 82.0 %; CI = 0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV{sub 95%} = 94.4 %, CI = 0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV{sub 95%} = 88.5 % and 92.3 %, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT. Conclusion: These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example

  12. Recalculation of dose for each fraction of treatment on TomoTherapy.

    Science.gov (United States)

    Thomas, Simon J; Romanchikova, Marina; Harrison, Karl; Parker, Michael A; Bates, Amy M; Scaife, Jessica E; Sutcliffe, Michael P F; Burnet, Neil G

    2016-01-01

    The VoxTox study, linking delivered dose to toxicity requires recalculation of typically 20-37 fractions per patient, for nearly 2000 patients. This requires a non-interactive interface permitting batch calculation with multiple computers. Data are extracted from the TomoTherapy(®) archive and processed using the computational task-management system GANGA. Doses are calculated for each fraction of radiotherapy using the daily megavoltage (MV) CT images. The calculated dose cube is saved as a digital imaging and communications in medicine RTDOSE object, which can then be read by utilities that calculate dose-volume histograms or dose surface maps. The rectum is delineated on daily MV images using an implementation of the Chan-Vese algorithm. On a cluster of up to 117 central processing units, dose cubes for all fractions of 151 patients took 12 days to calculate. Outlining the rectum on all slices and fractions on 151 patients took 7 h. We also present results of the Hounsfield unit (HU) calibration of TomoTherapy MV images, measured over an 8-year period, showing that the HU calibration has become less variable over time, with no large changes observed after 2011. We have developed a system for automatic dose recalculation of TomoTherapy dose distributions. This does not tie up the clinically needed planning system but can be run on a cluster of independent machines, enabling recalculation of delivered dose without user intervention. The use of a task management system for automation of dose calculation and outlining enables work to be scaled up to the level required for large studies.

  13. The management of multidrug-resistant Enterobacteriaceae.

    Science.gov (United States)

    Bassetti, Matteo; Peghin, Maddalena; Pecori, Davide

    2016-12-01

    Multidrug-resistant (MDR) Enterobacteriaceae are often related to the production of extended-spectrum b-lactamases (ESBLs) and carbapenemase-producing Enterobacteriaceae (CRE), and represent an increasing global threat. Recommendations for the therapeutic management of MDR-related infections, however, are mainly derived from retrospective and nonrandomized prospective studies. The aim of this review is to discuss the challenges in the treatment of patients with infections because of MDR Enterobacteriaceae and provide an expert opinion while awaiting for more definitive data. To avoid the selection of carbapenemase-producing Enterobacteriaceae, carbapenem-sparing strategies should be considered. B-lactams/b-lactamase inhibitors, mainly piperacillin-tazobactam, minimum inhibitory concentration (MIC) 16/4mg/ml or less represents the best alternative to carbapenems for the treatment of ESBL-producing strains. Overall, combination therapy may be preferred over monotherapy for CRE. The combination of a carbapenem-containing regimen with colistin or high-dose tigecycline or aminoglycoside can be administered at high-dose prolonged infusion with therapeutic drug monitoring for the treatment of CRE with MIC for meropenem 8-16 mg/l or less. For MIC higher than 8-16 mg/l, the use of meropenem should be avoided and various combination therapies based on the in-vitro susceptibility of antimicrobials (e.g., colistin, high-dose tigecycline, fosfomycin, and aminoglycosides) should be selected. Carbapenem-sparing strategies should be used, when feasible, for ESBL infections. The majority of available nonrandomized studies highlight that combination for CRE seem to offer some therapeutic advantage over monotherapy. Strict infection control measures toward MDR Gram-negative pathogens remain necessary while awaiting for new treatment options.

  14. Synchrotron accelerator technology for proton beam therapy with high accuracy

    International Nuclear Information System (INIS)

    Hiramoto, Kazuo

    2009-01-01

    Proton beam therapy was applied at the beginning to head and neck cancers, but it is now extended to prostate, lung and liver cancers. Thus the need for a pencil beam scanning method is increasing. With this method radiation dose concentration property of the proton beam will be further intensified. Hitachi group has supplied a pencil beam scanning therapy system as the first one for M. D. Anderson Hospital in United States, and it has been operational since May 2008. Hitachi group has been developing proton therapy system to correspond high-accuracy proton therapy to concentrate the dose in the diseased part which is located with various depths, and which sometimes has complicated shape. The author described here on the synchrotron accelerator technology that is an important element for constituting the proton therapy system. (K.Y.)

  15. Bitemporal v. high-dose right unilateral electroconvulsive therapy for depression: a systematic review and meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Kolshus, E; Jelovac, A; McLoughlin, D M

    2017-02-01

    Brief-pulse electroconvulsive therapy (ECT) is the most acutely effective treatment for severe depression though concerns persist about cognitive side-effects. While bitemporal electrode placement is the most commonly used form worldwide, right unilateral ECT causes less cognitive side-effects though historically it has been deemed less effective. Several randomized trials have now compared high-dose (>5× seizure threshold) unilateral ECT with moderate-dose (1.0-2.5× seizure threshold) bitemporal ECT to investigate if it is as effective as bitemporal ECT but still has less cognitive side-effects. We aimed to systematically review these trials and meta-analyse clinical and cognitive outcomes where appropriate. We searched PubMed, PsycINFO, Web of Science, Cochrane Library and EMBASE for randomized trials comparing these forms of ECT using the terms 'electroconvulsive' OR 'electroshock' AND 'trial'. Seven trials (n = 792) met inclusion criteria. Bitemporal ECT did not differ from high-dose unilateral ECT on depression rating change scores [Hedges's g = -0.03, 95% confidence interval (CI) -0.17 to 0.11], remission (RR 1.06, 95% CI 0.93-1.20), or relapse at 12 months (RR 1.42, 95% CI 0.90-2.23). There was an advantage for unilateral ECT on reorientation time after individual ECT sessions (mean difference in minutes = -8.28, 95% CI -12.86 to -3.70) and retrograde autobiographical memory (Hedges's g = -0.46, 95% CI -0.87 to -0.04) after completing an ECT course. There were no differences for general cognition, category fluency and delayed visual and verbal memory. High-dose unilateral ECT does not differ from moderate-dose bitemporal ECT in antidepressant efficacy but has some cognitive advantages.

  16. Dose De-escalation of Intrapleural Tissue Plasminogen Activator Therapy for Pleural Infection. The Alteplase Dose Assessment for Pleural Infection Therapy Project.

    Science.gov (United States)

    Popowicz, Natalia; Bintcliffe, Oliver; De Fonseka, Duneesha; Blyth, Kevin G; Smith, Nicola A; Piccolo, Francesco; Martin, Geoffrey; Wong, Donny; Edey, Anthony; Maskell, Nick; Lee, Y C Gary

    2017-06-01

    Intrapleural therapy with a combination of tissue plasminogen activator (tPA) 10 mg and DNase 5 mg administered twice daily has been shown in randomized and open-label studies to successfully manage over 90% of patients with pleural infection without surgery. Potential bleeding risks associated with intrapleural tPA and its costs remain important concerns. The aim of the ongoing Alteplase Dose Assessment for Pleural infection Therapy (ADAPT) project is to investigate the efficacy and safety of dose de-escalation for intrapleural tPA. The first of several planned studies is presented here. To evaluate the efficacy and safety of a reduced starting dose regimen of 5 mg of tPA with 5 mg of DNase administered intrapleurally for pleural infection. Consecutive patients with pleural infection at four participating centers in Australia, the United Kingdom, and New Zealand were included in this observational, open-label study. Treatment was initiated with tPA 5 mg and DNase 5 mg twice daily. Subsequent dose escalation was permitted at the discretion of the attending physician. Data relating to treatment success, radiological and systemic inflammatory changes (blood C-reactive protein), volume of fluid drained, length of hospital stay, and treatment complications were extracted retrospectively from the medical records. We evaluated 61 patients (41 males; age, 57 ± 16 yr). Most patients (n = 58 [93.4%]) were successfully treated without requiring surgery for pleural infection. Treatment success was corroborated by clearance of pleural opacities visualized by chest radiography (from 42% [interquartile range, 22-58] to 16% [8-31] of hemithorax; P < 0.001), increase in pleural fluid drainage (from 175 ml in the 24 h preceding treatment to 2,025 ml [interquartile range, 1,247-2,984] over 72 h of therapy; P <  0.05) and a reduction in blood C-reactive protein (P < 0.05). Seven patients (11.5%) had dose escalation of tPA to 10 mg. Three patients underwent

  17. Spine stereotactic body radiation therapy plans: Achieving dose coverage, conformity, and dose falloff

    International Nuclear Information System (INIS)

    Hong, Linda X.; Shankar, Viswanathan; Shen, Jin; Kuo, Hsiang-Chi; Mynampati, Dinesh; Yaparpalvi, Ravindra; Goddard, Lee; Basavatia, Amar; Fox, Jana; Garg, Madhur; Kalnicki, Shalom; Tomé, Wolfgang A.

    2015-01-01

    We report our experience of establishing planning objectives to achieve dose coverage, conformity, and dose falloff for spine stereotactic body radiation therapy (SBRT) plans. Patients with spine lesions were treated using SBRT in our institution since September 2009. Since September 2011, we established the following planning objectives for our SBRT spine plans in addition to the cord dose constraints: (1) dose coverage—prescription dose (PD) to cover at least 95% planning target volume (PTV) and 90% PD to cover at least 99% PTV; (2) conformity index (CI)—ratio of prescription isodose volume (PIV) to the PTV < 1.2; (3) dose falloff—ratio of 50% PIV to the PTV (R 50% ); (4) and maximum dose in percentage of PD at 2 cm from PTV in any direction (D 2cm ) to follow Radiation Therapy Oncology Group (RTOG) 0915. We have retrospectively reviewed 66 separate spine lesions treated between September 2009 and December 2012 (31 treated before September 2011 [group 1] and 35 treated after [group 2]). The χ 2 test was used to examine the difference in parameters between groups. The PTV V 100% PD ≥ 95% objective was met in 29.0% of group 1 vs 91.4% of group 2 (p < 0.01) plans. The PTV V 90% PD ≥ 99% objective was met in 38.7% of group 1 vs 88.6% of group 2 (p < 0.01) plans. Overall, 4 plans in group 1 had CI > 1.2 vs none in group 2 (p = 0.04). For D 2cm , 48.3% plans yielded a minor violation of the objectives and 16.1% a major violation for group 1, whereas 17.1% exhibited a minor violation and 2.9% a major violation for group 2 (p < 0.01). Spine SBRT plans can be improved on dose coverage, conformity, and dose falloff employing a combination of RTOG spine and lung SBRT protocol planning objectives

  18. Spine stereotactic body radiation therapy plans: Achieving dose coverage, conformity, and dose falloff

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Linda X., E-mail: lhong0812@gmail.com [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY (United States); Shankar, Viswanathan [Department of Epidemiology and Population Health, Albert Einstein College of Medicine, Bronx, NY (United States); Shen, Jin [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Kuo, Hsiang-Chi [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY (United States); Mynampati, Dinesh [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Yaparpalvi, Ravindra [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY (United States); Goddard, Lee [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Basavatia, Amar; Fox, Jana; Garg, Madhur; Kalnicki, Shalom; Tomé, Wolfgang A. [Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY (United States); Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY (United States)

    2015-10-01

    We report our experience of establishing planning objectives to achieve dose coverage, conformity, and dose falloff for spine stereotactic body radiation therapy (SBRT) plans. Patients with spine lesions were treated using SBRT in our institution since September 2009. Since September 2011, we established the following planning objectives for our SBRT spine plans in addition to the cord dose constraints: (1) dose coverage—prescription dose (PD) to cover at least 95% planning target volume (PTV) and 90% PD to cover at least 99% PTV; (2) conformity index (CI)—ratio of prescription isodose volume (PIV) to the PTV < 1.2; (3) dose falloff—ratio of 50% PIV to the PTV (R{sub 50%}); (4) and maximum dose in percentage of PD at 2 cm from PTV in any direction (D{sub 2cm}) to follow Radiation Therapy Oncology Group (RTOG) 0915. We have retrospectively reviewed 66 separate spine lesions treated between September 2009 and December 2012 (31 treated before September 2011 [group 1] and 35 treated after [group 2]). The χ{sup 2} test was used to examine the difference in parameters between groups. The PTV V{sub 100%} {sub PD} ≥ 95% objective was met in 29.0% of group 1 vs 91.4% of group 2 (p < 0.01) plans. The PTV V{sub 90%} {sub PD} ≥ 99% objective was met in 38.7% of group 1 vs 88.6% of group 2 (p < 0.01) plans. Overall, 4 plans in group 1 had CI > 1.2 vs none in group 2 (p = 0.04). For D{sub 2cm}, 48.3% plans yielded a minor violation of the objectives and 16.1% a major violation for group 1, whereas 17.1% exhibited a minor violation and 2.9% a major violation for group 2 (p < 0.01). Spine SBRT plans can be improved on dose coverage, conformity, and dose falloff employing a combination of RTOG spine and lung SBRT protocol planning objectives.

  19. Evaluation of the dose distribution of dynamic conical conformal therapy using a C-arm mounted accelerator

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Aoki, Yukimasa; Ohtomo, Kuni

    2001-01-01

    Conformal radiation therapy, which is widely utilized in Japan as a standard, highly precise technique has limited advantage in dose confinement because of its coplanar beam entry. An improved form of conformal therapy is delivered by a linac mounted on a C-arm rotatable gantry. The linac head was designed to move along the C-arm with a maximum angle of 60 degrees. Simultaneous rotation of the gantry creates a Dynamic Conical irradiation technique. Dynamic Conical Conformal Therapy (Dyconic Therapy) was developed by combining the technique with continuous MLC motion based on beam's eye views of the target volume. Dose distributions were measured in a phantom using film densitometry and compared with conventional conformal radiation therapy. The measurements showed that the dose distribution conformed to the target shape identified by CT. In addition, the dose distribution for a cancer patient was evaluated through the use of DVHs generated by a treatment planning system. These measurements showed that the dose distribution along the patient's long axis conformed to the shape of the target volume. DVH analysis, however, did not indicate superiority of the present technique over the conventional technique. Angulation of the C-arm gantry allowed the primary beam to strike a larger area of the therapy room. This necessitated adding shielding to the walls and ceiling of the treatment room. It was confirmed that the leakage radiation was reduced to a negligible level by adding an iron plate 20 cm thick to several places on the side walls, by adding an iron plate 9 cm thick to several places on the ceiling, and by increasing the thickness of the concrete ceiling from 70 to 140 cm. The possible usefulness of Dyconic Therapy was confirmed. (author)

  20. Hypertonic saline solution and high-dose furosemide infusion in cardiorenal syndrome: our experience

    Directory of Open Access Journals (Sweden)

    Francesco Ventrella

    2013-03-01

    Full Text Available Introduction Heart failure is frequently complicated by renal failure, and this association is a negative prognostic factor. These patients sometimes present oligo-/anuria and resistance to high-dose furosemide, a condition referred to as the cardiorenal syndrome (CRS. Acute or chronic reductions in left ventricular function result in decreased blood flow, with reduction of renal perfusion and activation of several neurohormonal systems, which cause resistance to diuretic therapy. This condition often requires ultrafiltration, which is an effective, but invasive and expensive procedure. Infusions of hypertonic saline solution (HSS and high-dose furosemide can be an effective alternative. Materials and methods From November 2009 through May 2010, our team treated 20 patients with CRS and resistance to iv boluses of high-dose furosemide. These patients were treated with small-volume (150-250 mL infusions of HSS (NaCl 1.57 – 4.5%, depending on serum Na values and high-dose furosemide twice a day. The aim of this treatment is to modify renal hemodynamics and the water-saline balance in the kidney by counteracting the extracellular fluid accumulation and eliminating symptoms of congestion. Results In 18 patients (90%, urine output was restored and renal function improved during the first hours of treatment. Clinical improvement was evident from the first day of therapy, and there were no adverse events. Two patients (10% did not respond to the treatment: one (who had been in critical condition since admission died; the other required regular sessions of ultrafiltration. Conclusions HSS combined with high-dose furosemide is a safe, effective, low-cost approach to the treatment of CRS that is resistant to diuretic therapy.

  1. High-dose "1"3"1I-MIBG therapies in children: feasibility, patient dosimetry and radiation exposure to workers and family caregivers

    International Nuclear Information System (INIS)

    Cougnenc, Olivier; Defachelles, Anne-Sophie; Lervat, Cyril; Carpentier, Philippe; Oudoux, Aurore; Kolesnikov-Gauthier, Helene; Clisant, Stephanie

    2017-01-01

    The objective of the present multi-centric phase II study (MIITOP) was to determine the response rate, survival and toxicity of tandem infusions of "1"3"1I-meta-iodobenzylguanidine (mIBG) and topotecan in children with relapsed/refractory neuroblastoma. High-dose "1"3"1I-mIBG therapy programme requires a deal of planning, availability of hospital resources and the commitment of individuals with training and expertise in multiple disciplines. Here in the present study, procedures and the results of patient's dosimetry, as well as family and worker's exposures, were reported for the patients treated in Lille. A total of 15 children were treated with "1"3"1I-mIBG between 2009 and 2011 according to the MIITOP protocol. High activity of "1"3"1I-mIBG (444 MBq kg"-"1) was administered on Day 0. In vivo dosimetry was used to calculate a second activity, to be given on Day 21, to obtain a total whole body absorbed dose of 4 Gy. Family and worker's exposures were performed too. The injected activity by treatment was from 703 to 11470 MBq. Total whole body absorbed dose by patient ranged from 2.74 to 5.2 Gy. Concerning relatives, whole body exposure ranged from 0.018 to 2.8 mSv. The mean whole body exposure of the radio-pharmacist was 4.4 nSv MBq"-"1, and the mean exposure of fingers ranged from 0.18 to 0.24 μSv MBq"-"1 according to each finger. The mean whole body exposure was 33.6 and 20.2 μSv d"-"1 per person, for night nurses and day nurses, respectively. Exposure of doctors was less than 5 μSv d"-"1. Under strict radiation protection precautions, this study shows the feasibility of high-activity "1"3"1I-mIBG therapy in France. (authors)

  2. Fetus dose estimation in thyroid cancer post-surgical radioiodine therapy

    International Nuclear Information System (INIS)

    Mianji, Fereidoun A.; Karimi Diba, Jila; Babakhani, Asad

    2015-01-01

    Unrecognised pregnancy during radioisotope therapy of thyroid cancer results in hardly definable embryo/fetus exposures, particularly when the thyroid gland is already removed. Sources of such difficulty include uncertainty in data like pregnancy commencing time, amount and distribution of metastasized thyroid cells in body, effect of the thyroidectomy on the fetus dose coefficient etc. Despite all these uncertainties, estimation of the order of the fetus dose in most cases is enough for medical and legal decision-making purposes. A model for adapting the dose coefficients recommended by the well-known methods to the problem of fetus dose assessment in athyrotic patients is proposed. The model defines a correction factor for the problem and ensures that the fetus dose in athyrotic pregnant patients is less than the normal patients. A case of pregnant patient undergone post-surgical therapy by I-131 is then studied for quantitative comparison of the methods. The results draw a range for the fetus dose in athyrotic patients using the derived factor. This reduces the concerns on under- or over-estimation of the embryo/fetus dose and is helpful for personal and/or legal decision-making on abortion. (authors)

  3. Efficacy between high and medium doses of glucocorticoid therapy in remission induction of IgG4-related diseases: a preliminary randomized controlled trial.

    Science.gov (United States)

    Wu, Qingjun; Chang, Jie; Chen, Hua; Chen, Yu; Yang, Hongxian; Fei, Yunyun; Zhang, Panpan; Zeng, Xiaofeng; Zhang, Fengchun; Zhang, Wen

    2017-05-01

    In order to evaluate the efficacy and safety of high versus medium doses of glucocorticoid therapy in remission induction of immunoglobulin G4-related disease (IgG4-RD), we set up a randomized controlled study. Newly diagnosed IgG4-RD patients were randomly assigned to two groups: high doses of prednisone (0.8-1.0 mg/kg/day) and medium doses (0.5-0.6 mg/kg/day). Patients were assessed at weeks 0, 4, 12 and 24. The primary outcome was the remission rate at week 24. The secondary endpoints included IgG4-RD responder index (IgG4-RD RI), IgG and IgG4 levels. Twenty cases in each group finished the study. At week 24, the total response rates were 95% and 80% in high and medium dose groups, respectively. There was no significant difference between the two groups. IgG4-RD RI reduced from 14.9 to 3.0 in the high dose group, while in the medium dose group it was from 13.1 to 3.2. At week 24, the average level of IgG4 reduced from 1576 to 324 mg/dL and from 1445 to 684 mg/dL in the two groups, respectively. Relapsed patients had higher baseline IgG4-RD RI. There was no severe adverse effect shown in both groups. The effect of remission induction was similar in high and medium glucocorticoid groups. However, patients with more organs involved and higher IgG4-RD RI score at baseline might get more benefit with high dose glucocorticoid for remission induction. © 2017 Asia Pacific League of Associations for Rheumatology and John Wiley & Sons Australia, Ltd.

  4. Lack of benefit for the addition of androgen deprivation therapy to dose-escalated radiotherapy in the treatment of intermediate- and high-risk prostate cancer.

    LENUS (Irish Health Repository)

    Krauss, Daniel

    2012-02-01

    PURPOSE: Assessment of androgen deprivation therapy (ADT) benefits for prostate cancer treated with dose-escalated radiotherapy (RT). METHODS AND MATERIALS: From 1991 to 2004, 1,044 patients with intermediate- (n = 782) or high-risk (n = 262) prostate cancer were treated with dose-escalated RT at William Beaumont Hospital. Patients received external-beam RT (EBRT) alone, brachytherapy (high or low dose rate), or high dose rate brachytherapy plus pelvic EBRT. Intermediate-risk patients had Gleason score 7, prostate-specific antigen (PSA) 10.0-19.9 ng\\/mL, or Stage T2b-T2c. High-risk patients had Gleason score 8-10, PSA >\\/=20, or Stage T3. Patients were additionally divided specifically by Gleason score, presence of palpable disease, and PSA level to further define subgroups benefitting from ADT. RESULTS: Median follow-up was 5 years; 420 patients received ADT + dose-escalated RT, and 624 received dose-escalated RT alone. For all patients, no advantages in any clinical endpoints at 8 years were associated with ADT administration. No differences in any endpoints were associated with ADT administration based on intermediate- vs. high-risk group or RT modality when analyzed separately. Patients with palpable disease plus Gleason >\\/=8 demonstrated improved clinical failure rates and a trend toward improved survival with ADT. Intermediate-risk patients treated with brachytherapy alone had improved biochemical control when ADT was given. CONCLUSION: Benefits of ADT in the setting of dose-escalated RT remain poorly defined. This question must continue to be addressed in prospective study.

  5. Is It All about the Higher Dose? Why Psychoanalytic Therapy Is an Effective Treatment for Major Depression.

    Science.gov (United States)

    Zimmermann, Johannes; Löffler-Stastka, Henriette; Huber, Dorothea; Klug, Günther; Alhabbo, Sarah; Bock, Astrid; Benecke, Cord

    2015-01-01

    Empirical evidence for the effectiveness of long-term psychodynamic psychotherapy (LTPP) in patients with mood disorders is growing. However, it is unclear whether the effectiveness of LTPP is due to distinctive features of psychodynamic/psychoanalytic techniques or to a higher number of sessions. We tested these rival hypotheses in a quasi-experimental study comparing psychoanalytic therapy (i.e., high-dose LTPP) with psychodynamic therapy (i.e., low-dose LTPP) and cognitive-behavioural therapy (CBT) for depression. Analyses were based on a subsample of 77 subjects, with 27 receiving psychoanalytic therapy, 26 receiving psychodynamic therapy and 24 receiving CBT. Depressive symptoms, interpersonal problems and introject affiliation were assessed prior to treatment, after treatment and at the 1-, 2- and 3-year follow-ups. Psychoanalytic techniques were assessed from three audiotaped middle sessions per treatment using the Psychotherapy Process Q-Set. Subjects receiving psychoanalytic therapy reported having fewer interpersonal problems, treated themselves in a more affiliative way directly after treatment and tended to improve in depressive symptoms and interpersonal problems during follow-up as compared with patients receiving psychodynamic therapy and/or CBT. Multilevel mediation analyses suggested that post-treatment differences in interpersonal problems and introject affiliation were mediated by the higher number of sessions, and follow-up differences in depressive symptoms were mediated by the more pronounced application of psychoanalytic techniques. We also found some evidence for indirect treatment effects via psychoanalytic techniques on changes in introject affiliation during follow-up. These results provide support for the prediction that both a high dose and the application of psychoanalytic techniques facilitate therapeutic change in patients with major depression. Psychoanalytic therapy is an effective treatment for major depression, especially in the

  6. High-Dose Versus Low-Dose Pitavastatin in Japanese Patients With Stable Coronary Artery Disease (REAL-CAD): A Randomized Superiority Trial.

    Science.gov (United States)

    Taguchi, Isao; Iimuro, Satoshi; Iwata, Hiroshi; Takashima, Hiroaki; Abe, Mitsuru; Amiya, Eisuke; Ogawa, Takanori; Ozaki, Yukio; Sakuma, Ichiro; Nakagawa, Yoshihisa; Hibi, Kiyoshi; Hiro, Takafumi; Fukumoto, Yoshihiro; Hokimoto, Seiji; Miyauchi, Katsumi; Yamazaki, Tsutomu; Ito, Hiroshi; Otsuji, Yutaka; Kimura, Kazuo; Takahashi, Jun; Hirayama, Atsushi; Yokoi, Hiroyoshi; Kitagawa, Kazuo; Urabe, Takao; Okada, Yasushi; Terayama, Yasuo; Toyoda, Kazunori; Nagao, Takehiko; Matsumoto, Masayasu; Ohashi, Yasuo; Kaneko, Tetsuji; Fujita, Retsu; Ohtsu, Hiroshi; Ogawa, Hisao; Daida, Hiroyuki; Shimokawa, Hiroaki; Saito, Yasushi; Kimura, Takeshi; Inoue, Teruo; Matsuzaki, Masunori; Nagai, Ryozo

    2018-05-08

    Current guidelines call for high-intensity statin therapy in patients with cardiovascular disease on the basis of several previous "more versus less statins" trials. However, no clear evidence for more versus less statins has been established in an Asian population. In this prospective, multicenter, randomized, open-label, blinded end point study, 13 054 Japanese patients with stable coronary artery disease who achieved low-density lipoprotein cholesterol (LDL-C) fashion to high-dose (pitavastatin 4 mg/d; n=6526) or low-dose (pitavastatin 1 mg/d; n=6528) statin therapy. The primary end point was a composite of cardiovascular death, nonfatal myocardial infarction, nonfatal ischemic stroke, or unstable angina requiring emergency hospitalization. The secondary composite end point was a composite of the primary end point and clinically indicated coronary revascularization excluding target-lesion revascularization at sites of prior percutaneous coronary intervention. The mean age of the study population was 68 years, and 83% were male. The mean LDL-C level before enrollment was 93 mg/dL with 91% of patients taking statins. The baseline LDL-C level after the run-in period on pitavastatin 1 mg/d was 87.7 and 88.1 mg/dL in the high-dose and low-dose groups, respectively. During the entire course of follow-up, LDL-C in the high-dose group was lower by 14.7 mg/dL than in the low-dose group ( P Japanese patients with stable coronary artery disease. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01042730. © 2018 The Authors.

  7. High dose rate brachytherapy for oral cancer.

    Science.gov (United States)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Furukawa, Souhei; Koizumi, Masahiko; Ogawa, Kazuhiko

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer.

  8. Low dose versus high dose anti-snake venom therapy in the treatment of haematotoxic snake bite in South India.

    Science.gov (United States)

    Joseph, Imanto M; Kuriakose, Cijoy K; Dev, Anand Vimal; Philip, George A

    2017-10-01

    Most of the studies on the appropriate dose of anti-snake venom (ASV) are from tertiary hospitals and the guidelines are unclear. Our observational study compared the outcomes of two prevalent treatment regimes for haematotoxic snake bite in a secondary care hospital in South India. The time to normalisation of whole blood clotting time, mortality and complications were not different between the groups. The average dose of ASV required in the low and high dose groups were 106 mL and 246 mL, respectively. Consequently, patients who received low dose ASV incurred approximately 50% less expense. Urticarial rashes were also significantly fewer in the low dose group.

  9. Monte Carlo simulation of secondary neutron dose for scanning proton therapy using FLUKA.

    Directory of Open Access Journals (Sweden)

    Chaeyeong Lee

    Full Text Available Proton therapy is a rapidly progressing field for cancer treatment. Globally, many proton therapy facilities are being commissioned or under construction. Secondary neutrons are an important issue during the commissioning process of a proton therapy facility. The purpose of this study is to model and validate scanning nozzles of proton therapy at Samsung Medical Center (SMC by Monte Carlo simulation for beam commissioning. After the commissioning, a secondary neutron ambient dose from proton scanning nozzle (Gantry 1 was simulated and measured. This simulation was performed to evaluate beam properties such as percent depth dose curve, Bragg peak, and distal fall-off, so that they could be verified with measured data. Using the validated beam nozzle, the secondary neutron ambient dose was simulated and then compared with the measured ambient dose from Gantry 1. We calculated secondary neutron dose at several different points. We demonstrated the validity modeling a proton scanning nozzle system to evaluate various parameters using FLUKA. The measured secondary neutron ambient dose showed a similar tendency with the simulation result. This work will increase the knowledge necessary for the development of radiation safety technology in medical particle accelerators.

  10. Development of a standardized susceptibility test for Campylobacter with quality control ranges for ciprofloxacin, doxycycline, erythromycin, gentamicin, and meropenem

    DEFF Research Database (Denmark)

    McDermott, P. F.; Bodeis, S. M.; Aarestrup, Frank Møller

    2004-01-01

    -control (QC) strain. Minimal inhibitory concentration (MIC) QC ranges were determined for two incubation time/temperature combinations: 36degreesC for 48 hr and 42degreesC for 24 hr. Quality-control ranges were determined for ciprofloxacin, doxycycline, erythromycin, gentamicin, and meropenem. For all...

  11. 77 FR 11556 - Pediatric Studies of Meropenem Conducted in Accordance With Section 409I of the Public Health...

    Science.gov (United States)

    2012-02-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0918] Pediatric Studies of Meropenem Conducted in Accordance With Section 409I of the Public Health Service Act... of the Public Health Service Act (PHS Act) and submitted to the Director of the National Institutes...

  12. A reviewed technique for total body electron therapy using a Varian Clinac 2100C/D high dose rate treatment beam facility

    International Nuclear Information System (INIS)

    Oliver, L.D.; Xuereb, E.M.A.; Last, V.; Hunt, P.B.; Wilfert, A.

    1996-01-01

    Our (Royal North Shore Hospital) most recent linear accelerator acquisition is a Varian Clinac 2100C/D which has a high dose rate (approximately 25Gy per minute at 1 metre) total body electron option. We investigated the physical characteristics of the electron beam to develop a suitable method of treatment for total body electron therapy. The useful electron beam width is defined as 80cm above and below the reference height. Measurements of the electron dose received from the two angled electron beams showed a critical dependence on the gantry angles. The treatment protocol uses ten different patient angles, fractionated into directly opposing fields and treated seuqentially each day. A full cycle of treatment is completed in five days. (author)

  13. Fixed-dose combination therapy for the prevention of cardiovascular disease

    Science.gov (United States)

    de Cates, Angharad N; Farr, Matthew RB; Rees, Karen; Casas, Juan P; Huffman, Mark

    2014-01-01

    This is the protocol for a review and there is no abstract. The objectives are as follows: To determine the effectiveness of fixed-dose combination therapy on optimising CVD risk factors and reducing CVD fatal and non-fatal events for both primary and secondary prevention of CVD. Details of CVD events and risk factors included are listed in the methods. We will also determine any adverse events associated with taking fixed-dose combination therapy. This will include studies conducted in both developed and developing regions of the world. PMID:25267903

  14. Prostate-specific antigen bounce after high-dose rate brachytherapy with external beam radiation therapy for prostate cancer patients

    International Nuclear Information System (INIS)

    Sakamoto, Naotaka; Kakinoki, Hiroaki; Tsutsui, Akio; Yoshikawa, Masahiro; Iguchi, Atsushi; Matsunobu, Toru; Uehara, Satoru

    2008-01-01

    Prostate-specific antigen (PSA) bounce after high-dose rate (HDR) brachytherapy with external beam radiation therapy (EBRT) for prostate cancer patients was evaluated. Sixty-one patients treated with HDR-brachytherapy followed by EBRT had a minimum follow-up of 12 months (median, 24 months) in our institute. A PSA bounce was defined as a rise of at least 0.1 ng/ml greater than a previous PSA level, with a subsequent decline equal to, or less than, the initial nadir. A PSA bounce was noted in 16 (26.2%) of 61 patients (one patient had a PSA bounce twice). Median time to develop a PSA bounce was 18 months, but 23.5% developed a PSA bounce after 24 months. Median duration of PSA bounce was 6 months and 11.8% had increased PSA within a period of 12 months. Median bounce height was 0.2 ng/ml (range, 0.1 to 3.39 ng/ml). A bounce height of gerater than 2 ng/ml was seen in 11.8%. Clinical characteristics (age, prostate volume, neoadjuvant endocrine therapy, risk classification, stage, pretreatment PSA, Gleason score) do not predict whether or not there will be a PSA bounce. In patients treated with HDR-brachytherapy followed by EBRT, the incidence and characteristics of PSA bounce were similar to those in patients treated with low-dose rate brachytherapy. Physicians should be aware of the possibility of PSA bounce following HDR-brachytherapy with EBRT. (author)

  15. Short-term irradiation of the glioblastoma with high-dosed fractions

    International Nuclear Information System (INIS)

    Hinkelbein, W.; Bruggmoser, G.; Schmidt, M.; Wannenmacher, M.

    1984-01-01

    Compared to surgery alone, postoperative radiotherapy leads with glioblastomas (grade IV gliomas) to a significant improvement of the therapeutic results. The prolongation of survival time, however, is to a large extent compensated by the therapy itself (it normally implicates hospitalisation). Therefore, we tested the efficiency of rapid course irradiation with high fractions. 70 patients were treated daily with individual fractions of 3.5 Gy, 4 to 6 fractions per week. The entire dose amounted to 31.5 to 38.5 Gy. The average survival time was 33.5 weeks corresponding to the survival time known from the combined surgical and radiotherapeutical treatment of glioblastomas. An effective increase in therapy-free survival time seems possible, especially when the entire focal dose does not exceed 35 Gy. It is remarkable that the patients with the maximum exposure did not have the longest survival times and rates. Living conditions for the patients were similar to those with conventional fractioning, or even better. Rapid course irradiation with high fractions and a limited total dose (35 Gy) presently is - apart from the accelerated superfractioning - a successful measure to prolong the therapyfree survival time for patients with grade IV gliomas. (orig.) [de

  16. High-dose therapy and autologous transplantation for lymphoma: the Peter MacCallum Cancer institute experience

    International Nuclear Information System (INIS)

    Dowling, A.J.; Prince, H.M.; Wolf, M.; Januszewicz, H.; Seymour, J.F.; Gates, P.; Wirth, A.; Juneja, S.; Smith, J.G.

    2001-01-01

    High-dose therapy (HDT) with autologous bone marrow or blood cell transplantation for the treatment of lymphoma commenced at Peter MacCallum Cancer Institute in 1986. To examine the patient characteristics and outcomes of patients with non-Hodgkin's lymphoma (NHL) and Hodgkin's disease (HD) treated with HDT and autologous transplantation at our Institute in the first 10 years of the service (1986-95). A retrospective analysis was performed examining patient characteristics, prior chemotherapy regimens, pretransplant disease status, HDT regimen, source of stem cells, time for haematopoietic recovery, complications of transplantation, response rates, overall survival (OS) and progression-free survival (PFS). Sixty-seven patients with NHL were treated with an estimated 5-year OS rate of 44% (95% confidence interval (CI) 32-56%) and PFS rate of 34% (95% CI 21-44%). Factors independently predictive of an unfavourable PFS on multivariate analyses were presence of constitutional symptoms at transplant (P < 0.002) and chemotherapy-resistant disease at transplant (P= 0.02). Twenty-three patients with HD were treated with a 5-year predicted OS rate of 74% (95% CI 56-92%) and PFS rate of 57% (95% CI 36-77%).There was no difference in PFS for HD patients who relapsed either within 12 months of completion of front-line therapy or after this time (P =0.5). The transplant-related mortality for the entire cohort was 17%, with a progressive decrease over time. HDT with autologous transplantation achieves durable PFS and OS in patients with lymphoma. Improved patient selection, therapy modifications according to prognostic factors and ongoing improvements in supportive care should improve outcomes further

  17. Insight into the Mechanism of Hydrolysis of Meropenem by OXA-23 Serine-β-lactamase Gained by Quantum Mechanics/Molecular Mechanics Calculations.

    Science.gov (United States)

    Sgrignani, Jacopo; Grazioso, Giovanni; De Amici, Marco

    2016-09-13

    The fast and constant development of drug resistant bacteria represents a serious medical emergency. To overcome this problem, the development of drugs with new structures and modes of action is urgently needed. In this work, we investigated, at the atomistic level, the mechanisms of hydrolysis of Meropenem by OXA-23, a class D β-lactamase, combining unbiased classical molecular dynamics and umbrella sampling simulations with classical force field-based and quantum mechanics/molecular mechanics potentials. Our calculations provide a detailed structural and dynamic picture of the molecular steps leading to the formation of the Meropenem-OXA-23 covalent adduct, the subsequent hydrolysis, and the final release of the inactive antibiotic. In this mechanistic framework, the predicted activation energy is in good agreement with experimental kinetic measurements, validating the expected reaction path.

  18. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  19. Dose, time and volume effects in interstitial radiation therapy

    International Nuclear Information System (INIS)

    Burgers, J.M.V.

    1982-01-01

    This study presents the main features and uncertainties of interstitial therapy and was undertaken to examine whether differences could be found in different clinical situations treated by interstitial implants with removable sources, that were not simply related to dose. In chapter 2, dating from 1978, continuous low dose rate irradiation is discussed from the radiobiological point of view together with some points related to variation in dose rate. A benefit of continuous low dose rate irradiation could be surmised in a few situations with special cell-kinetic properties. The problem of dose specification, the sharp dose gradient and other volume characteristics are discussed in chapter 3. Possible adjustments to variations in dose rate are discussed in chapter 4. The clinical material is reviewed in chapter 5, including aspects of dose specification, dose fall-off and variation in dose rate. The general discussion and conclusions are given in chapter 6. (Auth.)

  20. Functional results of radioiodine therapy with a 300-GY absorbed dose in Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Willemsen, U.F. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Knesewitsch, P. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Kreisig, T. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Pickardt, C.R. (Dept. of Internal Medicine, Muenchen Univ. (Germany)); Kirsch, C.M. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany))

    1993-11-01

    The aim of this study was to assess the results of high-dose radioiodine therapy given to 43 patients with recurrent hyperthyroidism due to Graves' disease between 1986 and 1992. We chose an intrathyroidal absorbed dose of 300 Gy and determined the applied activity individually, which ranged from 240 to 3120 MBq with a median of 752 MBq. Hperthyroidism was eliminated in 86% of cases after 3 months and in 100% after 12 months. No patient required a second radioiodine treatment. The incidnece of hyperthyroidism was 63% after 3 months and 93% after 18 months. Neither the pretherapeutic thyroid-stimulating immunoglobulin level nor the degree of co-existing endocrine ophthalmopathy was correlated with the time at which hypothyroidism developed. Patients with previous radioiodine therapy developed hypothyroidism earlier than patients with previous thyroid surgery. The results show that ablative radioiodine therapy with a 300-Gy absorbed dose is a very effective treatment of hyperthyroidism in Graves' disease, but it should be restricted to patients with recurrent hyperthyroidism combined with severe co-existing disorders or episodes of unfavourable reactions to antithyroid drugs. (orig.)

  1. High-Dose Mannose-Binding Lectin Therapy for Ebola Virus Infection

    Science.gov (United States)

    2010-06-01

    host defense against a wide range of viral and other pathogens. MBL is a C-type lectin that recognizes hexose sugars including man- nose, glucose...should be evaluatedmore broadly as an immunotherapeutic agent for a wide spectrum of glycosylated pathogens. MATERIALS AND METHODS Production and... coagulation mod- ulators, antisense technologies, therapeutic antibodies and Table 1. Pharmacokinetic Parameters of Low- vs High-Dose Recombinant Human

  2. Gynecological brachytherapy - from low-dose-rate to high-tech. Gynaekologische Brachytherapie - von Low-dose-rate zu High-tech

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, T. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany)); Christen, N. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany)); Alheit, H.D. (Abt. Strahlenthgerapie, Klinik und Poliklinik fuer Radiologie, Medizinische Akademie ' Carl Gustav Carus' , Dresden (Germany))

    1993-03-01

    The transition from low-dose-rate (LDR) brachytherapy to high-dose-rate (HDR) afterloading treatment is in progress in most centres of radiation therapy. First reports of studies comparing HDR and LDR treatment in cervix cancer demonstrate nearly equal local control. In our own investigations on 319 patients with primary irradiated carcinoma of the cervix (125 HDR/194 LDR) we found the following control rates: Stage FIGO I 95.4%/82.9% (HDR versus LDR), stage FIGO II 71.4%/73.7%, stage FIGO III 57.9%/38.5%. The results are not significant. The side effects - scored after EORT/RTOG criteria - showed no significant differences between both therapies for serious radiogenic late effects on intestine, bladder and vagina. The study and findings from the literature confirm the advantage of the HDR-procedure for patient and radiooncologist and for radiation protection showing at least the same results as in the LDR-area. As for radiobiolgical point of view it is important to consider that the use of fractionation in the HDR-treatment is essential for the sparing of normal tissues and therefore a greater number of small fractionation doses in the brachytherapy should be desirable too. On the other hand the rules, which are true for fractionated percutaneous irradiation therapy (overall treatment time as short as possible to avoid reppopulation of tumor cells) should be taken into consideration in combined brachy-teletherapy regime in gynecologic tumors. The first step in this direction may be accelerated regime with a daily application of both treatment procedures. The central blocking of the brachytherapy region from the whole percutaneous treatment target volume should be critically reflected, especially in the case of advanced tumors. (orig.)

  3. Effect of high-dose oral multivitamins and minerals in participants not treated with statins in the randomized Trial to Assess Chelation Therapy (TACT).

    Science.gov (United States)

    Issa, Omar M; Roberts, Rhonda; Mark, Daniel B; Boineau, Robin; Goertz, Christine; Rosenberg, Yves; Lewis, Eldrin F; Guarneri, Erminia; Drisko, Jeanne; Magaziner, Allan; Lee, Kerry L; Lamas, Gervasio A

    2018-01-01

    In a prespecified subgroup analysis of participants not on statin therapy at baseline in the TACT, a high-dose complex oral multivitamins and multimineral regimen was found to have a large unexpected benefit compared with placebo. The regimen tested was substantially different from any vitamin regimen tested in prior clinical trials. To explore these results, we performed detailed additional analyses of participants not on statins at enrollment in TACT. TACT was a factorial trial testing chelation treatments and a 28-component high-dose oral multivitamins and multiminerals regimen versus placebo in post-myocardial infarction (MI) patients 50 years or older. There were 460 (27%) of 1,708 TACT participants not taking statins at baseline, 224 (49%) were in the active vitamin group and 236 (51%) were in the placebo group. Patients were enrolled at 134 sites around the United States and Canada. Daily high-dose oral multivitamins and multiminerals (6 tablets, active or placebo). The primary end point of TACT was time to the first occurrence of any component of the composite end point: all-cause mortality, MI, stroke, coronary revascularization, or hospitalization for angina. The primary end point occurred in 137 nonstatin participants (30%), of which 51 (23%) of 224 were in the active group and 86 (36%) of 236 were taking placebo (hazard ratio, 0.62; 95% confidence interval, 0.44-0.87; P=.006). Results in the key TACT secondary end point, a combination of cardiovascular mortality, stroke, or recurrent MI, was consistent in favoring the active vitamin group (hazard ratio, 0.46; 95% confidence interval, 0.28-0.75; P=.002). Multiple end point analyses were consistent with these results. High-dose oral multivitamin and multimineral supplementation seem to decrease combined cardiac events in a stable, post-MI population not taking statin therapy at baseline. These unexpected findings are being retested in the ongoing TACT2. Copyright © 2017 The Authors. Published by Elsevier

  4. Hypofractionated High-Dose Radiation Therapy for Prostate Cancer: Long-Term Results of a Multi-Institutional Phase II Trial

    Energy Technology Data Exchange (ETDEWEB)

    Fonteyne, Valerie, E-mail: valerie.fonteyne@uzgent.be [Department of Radiotherapy, Ghent University Hospital, Ghent (Belgium); Soete, Guy [Department of Radiotherapy, Universitair Ziekenhuis Brussels, Jette (Belgium); Arcangeli, Stefano [Department of Radiotherapy, Regina Elena National Cancer Institute, Rome (Italy); De Neve, Wilfried [Department of Radiotherapy, Ghent University Hospital, Ghent (Belgium); Rappe, Bernard [Department of Urology, Algemeen Stedelijk Ziekenhuis, Aalst (Belgium); Storme, Guy [Department of Radiotherapy, Universitair Ziekenhuis Brussels, Jette (Belgium); Strigari, Lidia [Laboratory of Medical Physics and Expert Systems, Regina Elena National Cancer Institute, Rome (Italy); Arcangeli, Giorgio [Department of Radiotherapy, Regina Elena National Cancer Institute, Rome (Italy); De Meerleer, Gert [Department of Radiotherapy, Ghent University Hospital, Ghent (Belgium)

    2012-11-15

    Purpose: To report late gastrointestinal (GI) and genitourinary (GU) toxicity, biochemical and clinical outcomes, and overall survival after hypofractionated radiation therapy for prostate cancer (PC). Methods and Materials: Three institutions included 113 patients with T1 to T3N0M0 PC in a phase II study. Patients were treated with 56 Gy in 16 fractions over 4 weeks. Late toxicity was scored using Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria extended with additional symptoms. Biochemical outcome was reported according to the Phoenix definition for biochemical failure. Results: The incidence of late GI and GU toxicity was low. The 3-year actuarial risk of developing late GU and GI toxicity of grade {>=}2 was 13% and 8% respectively. Five-year biochemical non-evidence of disease (bNED) was 94%. Risk group, T stage, and deviation from planned hormone treatment were significant predictive factors for bNED. Deviation from hormone treatment remained significant in multivariate analysis. Five-year clinical non evidence of disease and overall survival was 95% and 91% respectively. No patient died from PC. Conclusions: Hypofractionated high-dose radiation therapy is a valuable treatment option for patients with PC, with excellent biochemical and clinical outcome and low toxicity.

  5. Phylogeographic, genomic, and meropenem susceptibility analysis of Burkholderia ubonensis.

    Science.gov (United States)

    Price, Erin P; Sarovich, Derek S; Webb, Jessica R; Hall, Carina M; Jaramillo, Sierra A; Sahl, Jason W; Kaestli, Mirjam; Mayo, Mark; Harrington, Glenda; Baker, Anthony L; Sidak-Loftis, Lindsay C; Settles, Erik W; Lummis, Madeline; Schupp, James M; Gillece, John D; Tuanyok, Apichai; Warner, Jeffrey; Busch, Joseph D; Keim, Paul; Currie, Bart J; Wagner, David M

    2017-09-01

    The bacterium Burkholderia ubonensis is commonly co-isolated from environmental specimens harbouring the melioidosis pathogen, Burkholderia pseudomallei. B. ubonensis has been reported in northern Australia and Thailand but not North America, suggesting similar geographic distribution to B. pseudomallei. Unlike most other Burkholderia cepacia complex (Bcc) species, B. ubonensis is considered non-pathogenic, although its virulence potential has not been tested. Antibiotic resistance in B. ubonensis, particularly towards drugs used to treat the most severe B. pseudomallei infections, has also been poorly characterised. This study examined the population biology of B. ubonensis, and includes the first reported isolates from the Caribbean. Phylogenomic analysis of 264 B. ubonensis genomes identified distinct clades that corresponded with geographic origin, similar to B. pseudomallei. A small proportion (4%) of strains lacked the 920kb chromosome III replicon, with discordance of presence/absence amongst genetically highly related strains, demonstrating that the third chromosome of B. ubonensis, like other Bcc species, probably encodes for a nonessential pC3 megaplasmid. Multilocus sequence typing using the B. pseudomallei scheme revealed that one-third of strains lack the "housekeeping" narK locus. In comparison, all strains could be genotyped using the Bcc scheme. Several strains possessed high-level meropenem resistance (≥32 μg/mL), a concern due to potential transmission of this phenotype to B. pseudomallei. In silico analysis uncovered a high degree of heterogeneity among the lipopolysaccharide O-antigen cluster loci, with at least 35 different variants identified. Finally, we show that Asian B. ubonensis isolate RF23-BP41 is avirulent in the BALB/c mouse model via a subcutaneous route of infection. Our results provide several new insights into the biology of this understudied species.

  6. Rapid Onset of Retinal Toxicity From High-Dose Hydroxychloroquine Given for Cancer Therapy.

    Science.gov (United States)

    Leung, Loh-Shan B; Neal, Joel W; Wakelee, Heather A; Sequist, Lecia V; Marmor, Michael F

    2015-10-01

    To report rapid onset of retinal toxicity in a series of patients followed on high-dose (1000 mg daily) hydroxychloroquine during an oncologic clinical trial studying hydroxychloroquine with erlotinib for non-small cell lung cancer. Retrospective observational case series. Ophthalmic surveillance was performed on patients in a multicenter clinical trial testing high-dose (1000 mg daily) hydroxychloroquine for advanced non-small cell lung cancer. The US Food & Drug Administration-recommended screening protocol included only visual acuity testing, dilated fundus examination, Amsler grid testing, and color vision testing. In patients seen at Stanford, additional sensitive screening procedures were added at the discretion of the retinal physician: high-resolution spectral-domain optical coherence tomography (OCT), fundus autofluorescence (FAF) imaging, Humphrey visual field (HVF) testing, and multifocal electroretinography (mfERG). Out of the 7 patients having exposure of at least 6 months, 2 developed retinal toxicity (at 11 and 17 months of exposure). Damage was identified by OCT imaging, mfERG testing, and, in 1 case, visual field testing. Fundus autofluorescence imaging remained normal. Neither patient had symptomatic visual acuity loss. These cases show that high doses of hydroxychloroquine can initiate the development of retinal toxicity within 1-2 years. Although synergy with erlotinib is theoretically possible, there are no prior reports of erlotinib-associated retinal toxicity despite over a decade of use in oncology. These results also suggest that sensitive retinal screening tests should be added to ongoing and future clinical trials involving high-dose hydroxychloroquine to improve safety monitoring and preservation of vision. Published by Elsevier Inc.

  7. Development of dose delivery verification by PET imaging of photonuclear reactions following high energy photon therapy

    International Nuclear Information System (INIS)

    Janek, S; Svensson, R; Jonsson, C; Brahme, A

    2006-01-01

    A method for dose delivery monitoring after high energy photon therapy has been investigated based on positron emission tomography (PET). The technique is based on the activation of body tissues by high energy bremsstrahlung beams, preferably with energies well above 20 MeV, resulting primarily in 11 C and 15 O but also 13 N, all positron-emitting radionuclides produced by photoneutron reactions in the nuclei of 12 C, 16 O and 14 N. A PMMA phantom and animal tissue, a frozen hind leg of a pig, were irradiated to 10 Gy and the induced positron activity distributions were measured off-line in a PET camera a couple of minutes after irradiation. The accelerator used was a Racetrack Microtron at the Karolinska University Hospital using 50 MV scanned photon beams. From photonuclear cross-section data integrated over the 50 MV photon fluence spectrum the predicted PET signal was calculated and compared with experimental measurements. Since measured PET images change with time post irradiation, as a result of the different decay times of the radionuclides, the signals from activated 12 C, 16 O and 14 N within the irradiated volume could be separated from each other. Most information is obtained from the carbon and oxygen radionuclides which are the most abundant elements in soft tissue. The predicted and measured overall positron activities are almost equal (-3%) while the predicted activity originating from nitrogen is overestimated by almost a factor of two, possibly due to experimental noise. Based on the results obtained in this first feasibility study the great value of a combined radiotherapy-PET-CT unit is indicated in order to fully exploit the high activity signal from oxygen immediately after treatment and to avoid patient repositioning. With an RT-PET-CT unit a high signal could be collected even at a dose level of 2 Gy and the acquisition time for the PET could be reduced considerably. Real patient dose delivery verification by means of PET imaging seems to be

  8. High dose rate brachytherapy for oral cancer

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Koizumi, Masahiko; Ogawa, Kazuhiko; Furukawa, Souhei

    2013-01-01

    Brachytherapy results in better dose distribution compared with other treatments because of steep dose reduction in the surrounding normal tissues. Excellent local control rates and acceptable side effects have been demonstrated with brachytherapy as a sole treatment modality, a postoperative method, and a method of reirradiation. Low-dose-rate (LDR) brachytherapy has been employed worldwide for its superior outcome. With the advent of technology, high-dose-rate (HDR) brachytherapy has enabled health care providers to avoid radiation exposure. This therapy has been used for treating many types of cancer such as gynecological cancer, breast cancer, and prostate cancer. However, LDR and pulsed-dose-rate interstitial brachytherapies have been mainstays for head and neck cancer. HDR brachytherapy has not become widely used in the radiotherapy community for treating head and neck cancer because of lack of experience and biological concerns. On the other hand, because HDR brachytherapy is less time-consuming, treatment can occasionally be administered on an outpatient basis. For the convenience and safety of patients and medical staff, HDR brachytherapy should be explored. To enhance the role of this therapy in treatment of head and neck lesions, we have reviewed its outcomes with oral cancer, including Phase I/II to Phase III studies, evaluating this technique in terms of safety and efficacy. In particular, our studies have shown that superficial tumors can be treated using a non-invasive mold technique on an outpatient basis without adverse reactions. The next generation of image-guided brachytherapy using HDR has been discussed. In conclusion, although concrete evidence is yet to be produced with a sophisticated study in a reproducible manner, HDR brachytherapy remains an important option for treatment of oral cancer. (author)

  9. Dose prescription in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gupta, N.M.S.; Gahbauer, R.A.; Blue, T.E.; Wambersie, A.

    1994-01-01

    The purpose of this paper is to address some aspects of the many considerations that need to go into a dose prescription in boron neutron capture therapy (BNCT) for brain tumors; and to describe some methods to incorporate knowledge from animal studies and other experiments into the process of dose prescription. Previously, an algorithm to estimate the normal tissue tolerance to mixed high and low linear energy transfer radiations in BNCT was proposed. The authors have developed mathematical formulations and computational methods to represent this algorithm. Generalized models to fit the central axis dose rate components for an epithermal neutron field were also developed. These formulations and beam fitting models were programmed into spreadsheets to simulate two treatment techniques which are expected to be used in BNCT: a two-field bilateral scheme and a single-field treatment scheme. Parameters in these spreadsheets can be varied to represent the fractionation scheme used, the 10 B microdistribution in normal tissue, and the ratio of 10 B in tumor to normal tissue. Most of these factors have to be determined for a given neutron field and 10 B compound combination from large animal studies. The spreadsheets have been programmed to integrate all of the treatment-related information and calculate the location along the central axis where the normal tissue tolerance is exceeded first. This information is then used to compute the maximum treatment time allowable and the maximum tumor dose that may be delivered for a given BNCT treatment. The effect of different treatment variables on the treatment time and tumor dose has been shown to be very significant. It has also been shown that the location of D max shifts significantly, depending on some of the treatment variables-mainly the fractionation scheme used. These results further emphasize the fact that dose prescription in BNCT is very complicated and nonintuitive. 11 refs., 6 figs., 3 tabs

  10. Quasi-VMAT in high-grade glioma radiation therapy.

    Science.gov (United States)

    Fadda, G; Massazza, G; Zucca, S; Durzu, S; Meleddu, G; Possanzini, M; Farace, P

    2013-05-01

    To compare a quasi-volumetric modulated arc therapy (qVMAT) with three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) for the treatment of high-grade gliomas. The qVMAT technique is a fast method of radiation therapy in which multiple equispaced beams analogous to those in rotation therapy are radiated in succession. This study included 12 patients with a planning target volume (PTV) that overlapped at least one organ at risk (OAR). 3D-CRT was planned using 2-3 non-coplanar beams, whereby the field-in-field technique (FIF) was used to divide each field into 1-3 subfields to shield the OAR. The qVMAT strategy was planned with 15 equispaced beams and IMRT was planned using 9 beams with a total of 80 segments. Inverse planning for qVMAT and IMRT was performed by direct machine parameter optimization (DMPO) to deliver a homogenous dose distribution of 60 Gy within the PTV and simultaneously limit the dose received by the OARs to the recommended values. Finally, the effect of introducing a maximum dose objective (max. dose < 54 Gy) for a virtual OAR in the form of a 0.5 cm ring around the PTV was investigated. The qVMAT method gave rise to significantly improved PTV95% and conformity index (CI) values in comparison to 3D-CRT (PTV95% = 90.7 % vs. 82.0 %; CI = 0.79 vs. 0.74, respectively). A further improvement was achieved by IMRT (PTV95% = 94.4 %, CI = 0.78). In qVMAT and IMRT, the addition of a 0.5 cm ring around the PTV produced a significant increase in CI (0.87 and 0.88, respectively), but dosage homogeneity within the PTV was considerably reduced (PTV95% = 88.5 % and 92.3 %, respectively). The time required for qVMAT dose delivery was similar to that required using 3D-CRT. These findings suggest that qVMAT should be preferred to 3D-CRT for the treatment of high-grade gliomas. The qVMAT method could be applied in hospitals, for example, which have limited departmental

  11. Fluorouracil and high-dose leucovorin with radiotherapy as adjuvant therapy for rectal cancer. Results of a phase II study

    Energy Technology Data Exchange (ETDEWEB)

    Giralt, J. [Radiation Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Rubio, D. [Medical Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Maldonado, X. [Radiation Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Naval, J. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Casado, S. [Medical Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Lara, F. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Rosello, J.M. [Dept. of Preventive Medicine, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Armengol, M. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain)

    1997-07-01

    The purpose of this phase II study was to evaluate the efficacy and toxicity of fluorouracil and high-dose leucovorin (5-FU/LV) with pelvic irradiation as adjuvant therapy for patients with macroscopical resected rectal or recto-sigmoid cancer. Following surgery for stages II-III primary (52) or recurrent rectal cancer (4), 56 patients received 8 cycles of 5-FU/LV and pelvic irradiation. 5-FU doses were 200 mgr/m{sup 2} for cycles 2-3 and 300 mgr/m{sup 2} for cycles 1 and 4-8. LV doses remained fixed at 200 mgr/m{sup 2}. Pelvic radiation was started in the third week, between the first and second cycle. The total dose was 50.4 Gy. No serve complications had been recorded. The incidence of grade 3 diarrhea was 19%. Three patients presented leukopenia grade 3 (5%). In 44 patients (78%) the planned treatment could be administered. The median follow-up was 40 months (range 22-66). Seven patients had a local relapse (13%) and 6 developed distant metastasis (10%). The 3-year disease-free survival was 72% and the overall survival was 76%. These preliminary results show that combined post-operative 5-FU/LV and pelvic radiotherapy are well tolerated and present a reasonable local control and survival rates. This adjuvant treatment should be evaluated in randomized trials. (orig.).

  12. Dose verification for respiratory-gated volumetric modulated arc therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qian Jianguo; Xing Lei; Liu Wu; Luxton, Gary, E-mail: gluxton@stanford.edu [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305 (United States)

    2011-08-07

    A novel commercial medical linac system (TrueBeam(TM), Varian Medical Systems, Palo Alto, CA) allows respiratory-gated volumetric modulated arc therapy (VMAT), a new modality for treating moving tumors with high precision and improved accuracy by allowing for regular motion associated with a patient's breathing during VMAT delivery. The purpose of this work is to adapt a previously-developed dose reconstruction technique to evaluate the fidelity of VMAT treatment during gated delivery under clinic-relevant periodic motion related to patient breathing. A Varian TrueBeam system was used in this study. VMAT plans were created for three patients with lung or pancreas tumors. Conventional 6 and 15 MV beams with flattening filter and high-dose-rate 10 MV beams with no flattening filter were used in these plans. Each patient plan was delivered to a phantom first without gating and then with gating for three simulated respiratory periods (3, 4.5 and 6 s). Using the adapted log-file-based dose reconstruction procedure supplemented with ion chamber array (Seven29(TM), PTW, Freiburg, Germany) measurements, the delivered dose was used to evaluate the fidelity of gated VMAT delivery. Comparison of Seven29 measurements with and without gating showed good agreement with gamma-index passing rates above 99% for 1%/1 mm dose accuracy/distance-to-agreement criteria. With original plans as reference, gamma-index passing rates were 100% for the reconstituted plans (1%/1 mm criteria) and 93.5-100% for gated Seven29 measurements (3%/3 mm criteria). In the presence of leaf error deliberately introduced into the gated delivery of a pancreas patient plan, both dose reconstruction and Seven29 measurement consistently indicated substantial dosimetric differences from the original plan. In summary, a dose reconstruction procedure was demonstrated for evaluating the accuracy of respiratory-gated VMAT delivery. This technique showed that under clinical operation, the TrueBeam system

  13. Radical surgical resection and high-dose intraoperative radiation therapy (HDR-IORT) in patients with recurrent gynecologic cancers

    International Nuclear Information System (INIS)

    Gemignani, Mary L.; Alektiar, Kaled M.; Leitao, Mario; Mychalczak, Boris; Chi, Dennis; Venkatraman, Ennapadam; Barakat, Richard R.; Curtin, John P.

    2001-01-01

    Objective: To determine the outcome for patients with recurrent gynecologic tumors treated with radical resection and combined high-dose intraoperative radiation therapy (HDR-IORT). Methods and Materials: Between November 1993 and June 1998, 17 patients with recurrent gynecologic malignancies underwent radical surgical resection and high-dose-rate brachytherapy. The mean age of the study group was 49 years (range 28-72 years). The site of the primary tumor was the cervix in 9 (53%) patients, the uterus in 7 (41%) patients, and the vagina in 1 (6%) patient. The treatment for the primary disease was surgery with or without adjuvant radiation in 14 (82%) patients and definitive radiation in 3 (18%) patients. The current surgery consisted of exenterative surgery in 10 (59%) patients and tumor resection in 7 (41%) patients. Complete gross resection was achieved in 13 (76%) patients. The mean HDR-IORT dose was 14 Gy (range 12-15). Additional radiation in the form of permanent Iodine-125 implant was given to 3 of 4 patients with gross residual disease. The median peripheral dose was 140 Gy. Results: With a median follow-up of 20 months (range 3-65 months), the 3-year actuarial local control (LC) rate was 67%. In patients with complete gross resection, the 3-year LC rate was 83%, compared to 25% in patients with gross residual disease, p<0.01. The 3-year distant metastasis disease-free and overall survival rates were 54% and 54%, respectively. The complications were as follows: gastrointestinal obstruction, 4 (24%); wound complications, 4 (24%); abscesses, 3 (18%); peripheral neuropathy, 3 (18%); rectovaginal fistula, 2 (12%); and ureteral obstruction, 2 (12%). Conclusion: Radical surgical resection and combined IORT for patients with recurrent gynecologic tumors seems to provide a reasonable local-control rate in patients who have failed prior surgery and/or definitive radiation. Patient selection is very important, however, as only those patients with complete gross

  14. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    Science.gov (United States)

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (agedphenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  15. Changes in tumor cell response due to prolonged dose delivery times in fractionated radiation therapy

    International Nuclear Information System (INIS)

    Paganetti, Harald

    2005-01-01

    Purpose: Dynamic radiation therapy, such as intensity-modulated radiation therapy, delivers more complex treatment fields than conventional techniques. The increased complexity causes longer dose delivery times for each fraction. The cellular damage after a full treatment may depend on the dose rate, because sublethal radiation damage can be repaired more efficiently during prolonged dose delivery. The goal of this study was to investigate the significance of this effect in fractionated radiation therapy. Methods and Materials: The lethal/potentially lethal model was used to calculate lesion induction rates for repairable and nonrepairable lesions. Dose rate effects were analyzed for 9 different cell lines (8 human tumor xenografts and a C3H10T1/2 cell line). The effects of single-fraction as well as fractionated irradiation for different dose rates were studied. Results: Significant differences can be seen for dose rates lower than about 0.1 Gy/min for all cell lines considered. For 60 Gy delivered in 30 fractions, the equivalent dose is reduced by between 1.3% and 12% comparing 2 Gy delivery over 30 min per fraction with 2 Gy delivery over 1 min per fraction. The effect is higher for higher doses per fraction. Furthermore, the results show that dose rate effects do not show a simple correlation with the α/β ratio for ratios between 3 Gy and 31 Gy. Conclusions: If the total dose delivery time for a treatment fraction in radiation therapy increases to about 20 min, a correction for dose rate effects may have to be considered in treatment planning. Adjustments in effective dose may be necessary when comparing intensity-modulated radiation therapy with conventional treatment plans

  16. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F.

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients. PMID:26820986

  17. Radiation therapy tolerance doses for treatment planning

    International Nuclear Information System (INIS)

    Lyman, J.T.

    1987-01-01

    To adequately plan acceptable dose distributions for radiation therapy treatments it is necessary to ensure that normal structures do not receive unacceptable doses. Acceptable doses are generally those that are below a stated tolerance dose for development of some level of complication. To support the work sponsored by the National Cancer Institute, data for the tolerance of normal tissues or organs to low-LET radiation has been compiled from a number of sources. These tolerance dose data are ostensibly for uniform irradiation of all or part of an organ, and are for either 5% (TD 5 ) or 50% (TD 50 ) complication probability. The ''size'' of the irradiated organ is variously stated in terms of the absolute volume or the fraction of the organ volume irradiated, or the area or the length of the treatment field. The accuracy of these data is questionable. Much of the data represent doses that one or several experienced therapists have estimated could be safely given rather than quantitative analyses of clinical observations. Because these data have been obtained from multiple sources with possible different criteria for the definition of a complication, there are sometimes different values for what is apparently the same end point. 20 refs., 1 fig., 1 tab

  18. Update on electroconvulsive therapy dosing strategies : review article

    African Journals Online (AJOL)

    Electroconvulsive Therapy (ECT) remains a controversial treatment modality, with a wide range of clinical practice and application. Recently significant advances in the technique of application of ECT have been made. These new approaches incorporate a variety of advances in ECT dosing strategies and techniques, ...

  19. High-dose I-131 MIBG treatment for young children with high-risk neuroblastoma, and its practical problem. From the experience of the youngest case in Japan

    International Nuclear Information System (INIS)

    Araki, Raita; Nishimura, Ryosei; Mase, Shintaro

    2012-01-01

    High-dose I-131 MIBG (metaiodobenzylguanidine) therapy combined with auto- or allo-hematopoietic stem cell transplantation is becoming a potential treatment for patients with high-risk neuroblastoma worldwide. However, only older children, who can perform personal care, had been given high-dose I-131 MIBG treatment to avoid the needless radiation exposure to caregivers and medical staff in Japan. In this case report, we have used the high dose MIBG therapy followed by autologous PBSCT (peripheral blood stem cell transplantation) for a 1-year-old boy with a newly diagnosed high-risk neuroblastoma with MYCN amplifications. The total radiation exposure to all parties involved was very limited, even in the youngest case in Japan, probably due to adequate preparations. This encouraging experience may remove the age limit for high-dose I-131 MIBG treatment for the patients with high-risk neuroblastoma in Japan. (author)

  20. Review of time-dose effects in radiation therapy

    International Nuclear Information System (INIS)

    Peschel, R.E.; Fischer, J.J.

    1980-01-01

    A historical review of conventional fractionation offers little confidence that such treatment is optimal for all tumors. Thus manipulation of time-dose schedules may provide a relatively inexpensive yet potentially useful technique for improving therapeutic results in radiation therapy. Consideration of basic radiobiological principles and animal model data illustrates the complex and heterogeneous nature of normal tissue and tumor response to time-dose effects and supports the hypothesis that better time-dose prescriptions can be found in clinical practice. The number of possible time-dose prescriptions is very large, and a review of the clinical trials using nonconventional fractionation demonstrates that the sampled portion of the total three-dimensional space of time, fraction number, and dose has been very small. Only carefully designed clinical trials can establish the therapeutic advantage of a new treatment schedule, and methods for selecting the most promising schedules are discussed. The use of simple data reduction formulas for time-dose effects should be discarded since they ignore the very complexity and heterogeneity of tissues and tumors which may form the basis of improved clinical results

  1. High-dose rate intra-operative radiation therapy for local advanced and recurrent colorectal cancer

    International Nuclear Information System (INIS)

    Harrison, L.B.; Mychalczak, B.; Enker, W.; Anderson, L.; Cohen, A.E.; Minsky, B.

    1996-01-01

    In an effort to improve the local control for advanced and recurrent cancers of the rectum, we have integrated high-dose rate intra-operative radiation therapy (HDR-IORT) into the treatment program. Between 11/92 and 10/95, 47 patients (pts) were treated. There were 26 males and 21 females whose ages ranged from 30-80 (median = 62) years. There were 19 pts with primary unresectable rectal cancer, and 28 pts who were treated for recurrent rectal cancer. Histology was adenocarcinoma - 45 pts, squamous cancer - 2 pts. The range of follow-up is 1-34 months (median = 14 months). The majority of primary unresectable pts received pre-operative radiation therapy (4500-5040 cGy) with chemotherapy (5-FU with Leucovorin) 4-6 weeks later, they underwent resection + HDR-IORT (1200 cGy). For the 28 pts with recurrent cancer, the majority received surgery and HDR-IORT alone because they had received prior RT. For the pts with primary unresectable disease, actuarial 2-year local control was 77%, actuarial distant metastasis-free survival was 71%, disease free survival was 66%, and overall survival was 84%. For those pts with recurrent disease, actuarial 2-year local control rate was 65%, distant metastasis-free survival was 65%, disease free survival was 47%, and overall survival was 61%. Complications occurred in 36%. There were no cases where the anatomical distribution of disease, or technical limitations prevented the adequate delivery of HDR-IORT. We conclude that this technique was most versatile, and enabled all appropriate pts to receive IORT. The preliminary data in terms of local control are encouraging, even for the poor prognostic sub-group of pts with recurrent cancer

  2. Precision Hypofractionated Radiation Therapy in Poor Performing Patients With Non-Small Cell Lung Cancer: Phase 1 Dose Escalation Trial

    Energy Technology Data Exchange (ETDEWEB)

    Westover, Kenneth D. [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Loo, Billy W. [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Gerber, David E. [Division of Hematology-Oncology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Iyengar, Puneeth; Choy, Hak [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Diehn, Maximilian [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Hughes, Randy; Schiller, Joan; Dowell, Jonathan [Division of Hematology-Oncology, Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Wardak, Zabi [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Sher, David [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); Christie, Alana; Xie, Xian-Jin [Department of Clinical Science, Southwestern Medical Center, Dallas, Texas (United States); Corona, Irma [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Sharma, Akanksha [School of Medicine, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Wadsworth, Margaret E. [Radiation Oncology of Mississippi, Jackson, Mississippi (United States); Timmerman, Robert, E-mail: Robert.Timmerman@utsouthwestern.edu [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States)

    2015-09-01

    Purpose: Treatment regimens for locally advanced non-small cell lung cancer (NSCLC) give suboptimal clinical outcomes. Technological advancements such as radiation therapy, the backbone of most treatment regimens, may enable more potent and effective therapies. The objective of this study was to escalate radiation therapy to a tumoricidal hypofractionated dose without exceeding the maximally tolerated dose (MTD) in patients with locally advanced NSCLC. Methods and Materials: Patients with stage II to IV or recurrent NSCLC and Eastern Cooperative Oncology Group performance status of 2 or greater and not candidates for surgical resection, stereotactic radiation, or concurrent chemoradiation were eligible. Highly conformal radiation therapy was given to treat intrathoracic disease in 15 fractions to a total of 50, 55, or 60 Gy. Results: Fifty-five patients were enrolled: 15 at the 50-Gy, 21 at the 55-Gy, and 19 at the 60-Gy dose levels. A 90-day follow-up was completed in each group without exceeding the MTD. With a median follow-up of 12.5 months, there were 93 grade ≥3 adverse events (AEs), including 39 deaths, although most AEs were considered related to factors other than radiation therapy. One patient from the 55- and 60-Gy dose groups developed grade ≥3 esophagitis, and 5, 4, and 4 patients in the respective dose groups experienced grade ≥3 dyspnea, but only 2 of these AEs were considered likely related to therapy. There was no association between fraction size and toxicity (P=.24). The median overall survival was 6 months with no significant differences between dose levels (P=.59). Conclusions: Precision hypofractionated radiation therapy consisting of 60 Gy in 15 fractions for locally advanced NSCLC is generally well tolerated. This treatment regimen could provide patients with poor performance status a potent alternative to chemoradiation. This study has implications for the cost effectiveness of lung cancer therapy. Additional studies of long

  3. Thyrotoxicosis and radioiodine therapy: Does the dose matter?

    Directory of Open Access Journals (Sweden)

    Andrew Collier

    2012-01-01

    Full Text Available There are 3 treatment options for thyrotoxicosis: Antithyroid drugs, Surgery and radioiodine. The choice of treatment varies geographically. Radioiodine therapy is preferred in the United States. The aim of radioiodine is to destroy sufficient thyroid tissue to cure the hyperthyroidism. There is a lack of consensus towards what dose of radioiodine should be used. Several methods are used to determine the dose. In our practice we administer 400 MBq to patients with Graves and in patients with large multinodular goiter, we would administer 800 MBq.

  4. Relationship between irreversible alopecia and exposure to cyclophosphamide, thiotepa and carboplatin (CTC) in high-dose chemotherapy

    NARCIS (Netherlands)

    de Jonge, M. E.; Mathôt, R. A. A.; Dalesio, O.; Huitema, A. D. R.; Rodenhuis, S.; Beijnen, J. H.

    2002-01-01

    Reversible alopecia is a commonly observed, important and distressing complication of chemotherapy. Permanent alopecia, however, is rare after standard-dose therapy, but has occasionally been observed after high-dose chemotherapy with cyclophosphamide, thiotepa and carboplatin (CTC). We evaluated

  5. Analytical probabilistic modeling of RBE-weighted dose for ion therapy

    Science.gov (United States)

    Wieser, H. P.; Hennig, P.; Wahl, N.; Bangert, M.

    2017-12-01

    Particle therapy is especially prone to uncertainties. This issue is usually addressed with uncertainty quantification and minimization techniques based on scenario sampling. For proton therapy, however, it was recently shown that it is also possible to use closed-form computations based on analytical probabilistic modeling (APM) for this purpose. APM yields unique features compared to sampling-based approaches, motivating further research in this context. This paper demonstrates the application of APM for intensity-modulated carbon ion therapy to quantify the influence of setup and range uncertainties on the RBE-weighted dose. In particular, we derive analytical forms for the nonlinear computations of the expectation value and variance of the RBE-weighted dose by propagating linearly correlated Gaussian input uncertainties through a pencil beam dose calculation algorithm. Both exact and approximation formulas are presented for the expectation value and variance of the RBE-weighted dose and are subsequently studied in-depth for a one-dimensional carbon ion spread-out Bragg peak. With V and B being the number of voxels and pencil beams, respectively, the proposed approximations induce only a marginal loss of accuracy while lowering the computational complexity from order O(V × B^2) to O(V × B) for the expectation value and from O(V × B^4) to O(V × B^2) for the variance of the RBE-weighted dose. Moreover, we evaluated the approximated calculation of the expectation value and standard deviation of the RBE-weighted dose in combination with a probabilistic effect-based optimization on three patient cases considering carbon ions as radiation modality against sampled references. The resulting global γ-pass rates (2 mm,2%) are > 99.15% for the expectation value and > 94.95% for the standard deviation of the RBE-weighted dose, respectively. We applied the derived analytical model to carbon ion treatment planning, although the concept is in general applicable to other

  6. Can we avoid high levels of dose escalation for high-risk prostate cancer in the setting of androgen deprivation?

    Directory of Open Access Journals (Sweden)

    Shakespeare TP

    2016-05-01

    Full Text Available Thomas P Shakespeare,1,2 Shea W Wilcox,1 Noel J Aherne1,2 1Department of Radiation Oncology, North Coast Cancer Institute, 2Rural Clinical School, Faculty of Medicine, University of New South Wales, Coffs Harbour, NSW, Australia Aim: Both dose-escalated external beam radiotherapy (DE-EBRT and androgen deprivation therapy (ADT improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients and methods: Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3–6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. Results: In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. Conclusion: There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered. Keywords: radiotherapy, IMRT, dose

  7. SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

    Energy Technology Data Exchange (ETDEWEB)

    Pham, R; Sun, B; Zhao, T; Li, H; Yang, D; Grantham, K; Goddu, S; Santanam, L; Bradley, J; Mutic, S; Kandlakunta, P; Zhang, T [Washington University School of Medicine, Saint Louis, MO (United States)

    2016-06-15

    Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculated on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.

  8. Updated Outcome and Analysis of Tumor Response in Mobile Spine and Sacral Chordoma Treated With Definitive High-Dose Photon/Proton Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kabolizadeh, Peyman, E-mail: peyman.kabolizadeh@beaumont.org [Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States); Chen, Yen-Lin; Liebsch, Norbert [Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States); Hornicek, Francis J.; Schwab, Joseph H. [Department of Orthopedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States); Choy, Edwin [Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States); Rosenthal, Daniel I. [Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States); Niemierko, Andrzej; DeLaney, Thomas F. [Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States)

    2017-02-01

    Purpose: Treatment of spine and sacral chordoma generally involves surgical resection, usually in conjunction with radiation therapy. In certain circumstances where resection may result in significant neurologic or organ dysfunction, patients can be treated definitively with radiation therapy alone. Herein, we report the outcome and the assessment of tumor response to definitive radiation therapy. Methods and Materials: A retrospective analysis was performed on 40 patients with unresected chordoma treated with photon/proton radiation therapy. Nineteen patients had complete sets of imaging scans. The soft tissue and bone compartments of the tumor were defined separately. Tumor response was evaluated by the modified Response Evaluation Criteria in Solid Tumors (RECIST) and volumetric analysis. Results: With a median follow-up time of 50.3 months, the rates of 5-year local control, overall survival, disease-specific survival, and distant failure were 85.4%, 81.9%, 89.4%, and 20.2%, respectively. Eighty-four computed tomographic and magnetic resonance imaging scans were reviewed. Among the 19 patients, only 4 local failures occurred, and the median tumor dose was 77.4 GyRBE. Analysis at a median follow-up time of 18 months showed significant volumetric reduction of the total target volume (TTV) and the soft tissue target volume (STTV) within the first 24 months after treatment initiation, followed by further gradual reduction throughout the rest of the follow-up period. The median maximum percentage volumetric regressions of TTV and STTV were 43.2% and 70.4%, respectively. There was only a small reduction in bone target volume over time. In comparison with the modified RECIST, volumetric analysis was more reliable, more reproducible, and could help in measuring minimal changes in the tumor volume. Conclusion: These results continue to support the use of high-dose definitive radiation therapy for selected patients with unresected spine and sacral chordomas

  9. Updated Outcome and Analysis of Tumor Response in Mobile Spine and Sacral Chordoma Treated With Definitive High-Dose Photon/Proton Radiation Therapy

    International Nuclear Information System (INIS)

    Kabolizadeh, Peyman; Chen, Yen-Lin; Liebsch, Norbert; Hornicek, Francis J.; Schwab, Joseph H.; Choy, Edwin; Rosenthal, Daniel I.; Niemierko, Andrzej; DeLaney, Thomas F.

    2017-01-01

    Purpose: Treatment of spine and sacral chordoma generally involves surgical resection, usually in conjunction with radiation therapy. In certain circumstances where resection may result in significant neurologic or organ dysfunction, patients can be treated definitively with radiation therapy alone. Herein, we report the outcome and the assessment of tumor response to definitive radiation therapy. Methods and Materials: A retrospective analysis was performed on 40 patients with unresected chordoma treated with photon/proton radiation therapy. Nineteen patients had complete sets of imaging scans. The soft tissue and bone compartments of the tumor were defined separately. Tumor response was evaluated by the modified Response Evaluation Criteria in Solid Tumors (RECIST) and volumetric analysis. Results: With a median follow-up time of 50.3 months, the rates of 5-year local control, overall survival, disease-specific survival, and distant failure were 85.4%, 81.9%, 89.4%, and 20.2%, respectively. Eighty-four computed tomographic and magnetic resonance imaging scans were reviewed. Among the 19 patients, only 4 local failures occurred, and the median tumor dose was 77.4 GyRBE. Analysis at a median follow-up time of 18 months showed significant volumetric reduction of the total target volume (TTV) and the soft tissue target volume (STTV) within the first 24 months after treatment initiation, followed by further gradual reduction throughout the rest of the follow-up period. The median maximum percentage volumetric regressions of TTV and STTV were 43.2% and 70.4%, respectively. There was only a small reduction in bone target volume over time. In comparison with the modified RECIST, volumetric analysis was more reliable, more reproducible, and could help in measuring minimal changes in the tumor volume. Conclusion: These results continue to support the use of high-dose definitive radiation therapy for selected patients with unresected spine and sacral chordomas

  10. Dose Dependent Survival Response in Chronic Myeloid Leukemia under Continuous and Pulsed Targeted Therapy

    International Nuclear Information System (INIS)

    Pizzolato, N.; Valenti, D.; Spagnolo, B.; Persano Adorno, D.

    2010-01-01

    A simulative study of cancer growth dynamics in patients affected by Chronic Myeloid Leukemia (CML), under the effect of a targeted dose dependent continuous or pulsed therapy, is presented. We have developed a model for the dynamics of CML in which the stochastic evolution of white blood cell populations are simulated by adopting a Monte Carlo approach. Several scenarios in the evolutionary dynamics of white blood cells, as a consequence of the efficacy of the different modelled therapies, pulsed or continuous, are described. The best results, in terms of a permanent disappearance of the leukemic phenotype, are achieved with a continuous therapy and higher dosage. However, our findings demonstrate that an intermittent therapy could represent a valid choice in patients with high risk of toxicity, when a long-term therapy is considered. A suitably tuned pulsed therapy can enhance the treatment efficacy and reduce the percentage of patients developing resistance. (authors)

  11. High-dose estrogen as salvage hormonal therapy for highly refractory metastatic breast cancer: a retrospective chart review.

    Science.gov (United States)

    Mahtani, Reshma L; Stein, Alisha; Vogel, Charles L

    2009-01-01

    High-dose estrogens (HDEs) are an efficacious but widely overlooked treatment option for patients with metastatic breast cancer (MBC). This is due in part to the introduction of tamoxifen in the 1970s, which was proven to be equivalent in efficacy and associated with fewer adverse events (AEs). The aim of this study was to report our experience with the use of HDE in postmenopausal women with advanced breast cancer. Local institutional review board approval was obtained to conduct a retrospective chart review of patients with MBC treated with HDEs at the Boca Raton Comprehensive Cancer Center, Boca Raton, Florida, from 2001 through March 2009. Demographic information, response rates, and tolerability profiles were collected. Of the 426 patients with MBC identified, we found 26 patients with MBC who were prescribed HDEs as a treatment in any line of therapy for advanced breast cancer. The median age at the start of HDE therapy was 59 years (range, 42-92 years). Three of the 26 patients (11.5%) were human epidermal growth factor receptor 2-positive determined via fluorescent in situ hybridization analysis. With the exception of 1 patient who had received no prior systemic treatment for metastatic disease, all patients received multiple lines of treatment (both chemotherapy and hormonal treatments) in the advanced setting (median, 7 lines; range, 0-12) prior to the initiation of HDE. Five of 20 patients (25%) with measurable metastatic disease (visceral and/or soft tissue metastases) had objective antitumor responses defined as either a partial response (PR) or a complete response (CR). Four additional patients (20%) had prolonged stable disease (SD) for > or =6 months. Three of 6 patients (50%) with nonmeasurable metastatic disease (bone-only) had prolonged SD for > or =6 months. Clinical benefit rate (defined as CR + PR + SD > or =6 months) for all patients was 46% (12/26), with a median duration of 10 months. Overall median progression-free survival for the 26

  12. Whole-Pelvic Nodal Radiation Therapy in the Context of Hypofractionation for High-Risk Prostate Cancer Patients: A Step Forward

    International Nuclear Information System (INIS)

    Kaidar-Person, Orit; Roach, Mack; Créhange, Gilles

    2013-01-01

    Given the low α/β ratio of prostate cancer, prostate hypofractionation has been tested through numerous clinical studies. There is a growing body of literature suggesting that with high conformal radiation therapy and even with more sophisticated radiation techniques, such as high-dose-rate brachytherapy or image-guided intensity modulated radiation therapy, morbidity associated with shortening overall treatment time with higher doses per fraction remains low when compared with protracted conventional radiation therapy to the prostate only. In high-risk prostate cancer patients, there is accumulating evidence that either dose escalation to the prostate or hypofractionation may improve outcome. Nevertheless, selected patients who have a high risk of lymph node involvement may benefit from whole-pelvic radiation therapy (WPRT). Although combining WPRT with hypofractionated prostate radiation therapy is feasible, it remains investigational. By combining modern advances in radiation oncology (high-dose-rate prostate brachytherapy, intensity modulated radiation therapy with an improved image guidance for soft-tissue sparing), it is hypothesized that WPRT could take advantage of recent results from hypofractionation trials. Moreover, the results from hypofractionation trials raise questions as to whether hypofractionation to pelvic lymph nodes with a high risk of occult involvement might improve the outcomes in WPRT. Although investigational, this review discusses the challenging idea of WPRT in the context of hypofractionation for patients with high-risk prostate cancer

  13. Whole-Pelvic Nodal Radiation Therapy in the Context of Hypofractionation for High-Risk Prostate Cancer Patients: A Step Forward

    Energy Technology Data Exchange (ETDEWEB)

    Kaidar-Person, Orit [Division of Oncology, Rambam Health Care Campus, Haifa (Israel); Roach, Mack [Department of Radiation Oncology, University of California, San Francisco, San Francisco, California (United States); Créhange, Gilles, E-mail: gcrehange@cgfl.fr [Department of Radiation Oncology, Georges-François Leclerc Cancer Center, Dijon (France)

    2013-07-15

    Given the low α/β ratio of prostate cancer, prostate hypofractionation has been tested through numerous clinical studies. There is a growing body of literature suggesting that with high conformal radiation therapy and even with more sophisticated radiation techniques, such as high-dose-rate brachytherapy or image-guided intensity modulated radiation therapy, morbidity associated with shortening overall treatment time with higher doses per fraction remains low when compared with protracted conventional radiation therapy to the prostate only. In high-risk prostate cancer patients, there is accumulating evidence that either dose escalation to the prostate or hypofractionation may improve outcome. Nevertheless, selected patients who have a high risk of lymph node involvement may benefit from whole-pelvic radiation therapy (WPRT). Although combining WPRT with hypofractionated prostate radiation therapy is feasible, it remains investigational. By combining modern advances in radiation oncology (high-dose-rate prostate brachytherapy, intensity modulated radiation therapy with an improved image guidance for soft-tissue sparing), it is hypothesized that WPRT could take advantage of recent results from hypofractionation trials. Moreover, the results from hypofractionation trials raise questions as to whether hypofractionation to pelvic lymph nodes with a high risk of occult involvement might improve the outcomes in WPRT. Although investigational, this review discusses the challenging idea of WPRT in the context of hypofractionation for patients with high-risk prostate cancer.

  14. Dose reporting in ion beam therapy. Proceedings of a meeting

    International Nuclear Information System (INIS)

    2007-06-01

    Following the pioneering work in Berkeley, USA, ion beam therapy for cancer treatment is at present offered in Chiba and Hyogo in Japan, and Darmstadt in Germany. Other facilities are coming close to completion or are at various stages of planning in Europe and Japan. In all these facilities, carbon ions have been selected as the ions of choice, at least in the first phase. Taking into account this fast development, the complicated technical and radiobiological research issues involved, and the hope it raises for some types of cancer patients, the IAEA and the International Commission on Radiation Units and measurements (ICRU) jointly sponsored a technical meeting held in Vienna, 23-24 June 2004. That first meeting was orientated mainly towards radiobiology: the relative biological effectiveness (RBE) of carbon ions versus photons, and related issues. One of the main differences between ion beam therapy and other modern radiotherapy techniques (such as proton beam therapy or intensity modulated radiation therapy) is related to radiobiology and in particular the increased RBE of carbon ions compared to both protons and photons (i.e., high linear energy transfer (LET) versus low LET radiation). Another important issue for international agencies and commissions, such as the IAEA and the ICRU, is a worldwide agreement and harmonisation for reporting the treatments. In order to evaluate the merits of ion beam therapy, it is essential that the treatments be reported in a similar/comparable way in all centres so that the clinical reports and protocols can be understood and interpreted without ambiguity by the radiation therapy community in general. For the last few decades, the ICRU has published several reports containing recommendations on how to report external photon beam or electron beam therapy, and brachytherapy. A report on proton beam therapy, jointly prepared by the ICRU and the IAEA, is now completed and is being published in the ICRU series. In line with this

  15. Retrospective Evaluation Reveals That Long-term Androgen Deprivation Therapy Improves Cause-Specific and Overall Survival in the Setting of Dose-Escalated Radiation for High-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    Feng, Felix Y.; Blas, Kevin; Olson, Karin; Stenmark, Matthew; Sandler, Howard; Hamstra, Daniel A.

    2013-01-01

    Purpose: To evaluate the role of androgen deprivation therapy (ADT) and duration for high-risk prostate cancer patients treated with dose-escalated radiation therapy (RT). Methods and Materials: A retrospective analysis of high-risk prostate cancer patients treated with dose-escalated RT (minimum 75 Gy) with or without ADT was performed. The relationship between ADT use and duration with biochemical failure (BF), metastatic failure (MF), prostate cancer-specific mortality (PCSM), non-prostate cancer death (NPCD), and overall survival (OS) was assessed as a function of pretreatment characteristics, comorbid medical illness, and treatment using Fine and Gray's cumulative incidence methodology. Results: The median follow-up time was 64 months. In men with National Comprehensive Cancer Network defined high-risk prostate cancer treated with dose-escalated RT, on univariate analysis, both metastasis (P<.0001; hazard ratio 0.34; 95% confidence interval 0.18-0.67; cumulative incidence at 60 months 13% vs 35%) and PCSM (P=.015; hazard ratio 0.41; 95% confidence interval 0.2-1.0; cumulative incidence at 60 months 6% vs 11%) were improved with the use of ADT. On multivariate analysis for all high-risk patients, Gleason score was the strongest negative prognostic factor, and long-term ADT (LTAD) improved MF (P=.002), PCSM (P=.034), and OS (P=.001). In men with prostate cancer and Gleason scores 8 to 10, on multivariate analysis after adjustment for other risk features, there was a duration-dependent improvement in BF, metastasis, PCSM, and OS, all favoring LTAD in comparison with STAD or RT alone. Conclusion: For men with high-risk prostate cancer treated with dose-escalated EBRT, this retrospective study suggests that the combination of LTAD and RT provided a significant improvement in clinical outcome, which was especially true for those with Gleason scores of 8 to 10

  16. Quantification of tomography images for dose calculation for diagnosis and therapy in nuclear medicine; Quantificacao de imagens tomograficas para calculo de dose em diagnose e terapia em medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Massicano, Felipe

    2010-07-01

    The nuclear medicine area has an increasing slope in the therapy of diseases, particularly in the treatment of radiosensitive tumors. Due to the high dose levels in radionuclide therapy, it is very important the accurate quantify of the dose distribution to avoid deleterious effects on healthy tissues. In Brazil, the internal dosimetry system used is the MIRD (Medical Internal Radiation Dose) based on a reference model that does not have adequate patient data to obtain a dose accurate assessment in therapy. However, in recent years, internal radionuclide dosimetry evaluates the spatial dose distribution base ad on information obtained from CT and SPECT or PET images together with the using of Monte Carlo codes. Those systems are called patient-specific dosimetry systems. In the Nuclear Engineering Center at IPEN, this methodology is in development. When the CT images are inserted into the Monte Carlo code MCNP5 through of use of a interface software called SCMS the dosimetry can be accomplished using patient-specific data, resulting in a more accurate energy deposition in organs of interest. This work aim to contribute with the development of part of that patient-specific dosimetry for therapy. To achieve this goal we have proposed three specific objectives: (1) Development of a software to convert images from Computed Tomography (CT) in the tissue parameters ({rho}, {omega}({iota})); (2) Development of a software to perform attenuation correction in nuclear medicine tomographic images (SPECT or PET) and to provide the map of relative activity and (3) Provide data to the SCMS code by these two software. The software developed for the rst specific objective was the Image Converter Computed Tomography (ICCT), which obtained a good accuracy to determine the density and the tissue composition; the elements that had high variation were carbon and oxygen. Fortunately, this variation for the energy range used in radionuclide therapy is not detrimental to the dose

  17. FEASIBILITY OF POSITRON EMISSION TOMOGRAPHY OF DOSE DISTRIBUTION IN PROTON BEAM CANCER THERAPY

    International Nuclear Information System (INIS)

    BEEBE-WANG, J.J.; DILMANIAN, F.A.; PEGGS, S.G.; SCHLYEER, D.J.; VASKA, P.

    2002-01-01

    Proton therapy is a treatment modality of increasing utility in clinical radiation oncology mostly because its dose distribution conforms more tightly to the target volume than x-ray radiation therapy. One important feature of proton therapy is that it produces a small amount of positron-emitting isotopes along the beam-path through the non-elastic nuclear interaction of protons with target nuclei such as 12 C, 14 N, and 16 O. These radioisotopes, mainly 11 C, 13 N and 15 O, allow imaging the therapy dose distribution using positron emission tomography (PET). The resulting PET images provide a powerful tool for quality assurance of the treatment, especially when treating inhomogeneous organs such as the lungs or the head-and-neck, where the calculation of the dose distribution for treatment planning is more difficult. This paper uses Monte Carlo simulations to predict the yield of positron emitters produced by a 250 MeV proton beam, and to simulate the productions of the image in a clinical PET scanner

  18. Patient-Specific Quality Assurance Using Monte Carlo Dose Calculation and Elekta Log Files for Prostate Volumetric-Modulated Arc Therapy.

    Science.gov (United States)

    Katsuta, Yoshiyuki; Kadoya, Noriyuki; Fujita, Yukio; Shimizu, Eiji; Matsunaga, Kenichi; Sawada, Kinya; Matsushita, Haruo; Majima, Kazuhiro; Jingu, Keiichi

    2017-12-01

    Log file-based methods are attracting increasing interest owing to their ability to validate volumetric-modulated arc therapy outputs with high resolution in the leaf and gantry positions and in delivered dose. Cross-validation of these methods for comparison with measurement-based methods using the ionization chamber/ArcCHECK-3DVH software (version 3.2.0) under the same conditions of treatment anatomy and plan enables an efficient evaluation of this method. In this study, with the purpose of cross-validation, we evaluate the accuracy of a log file-based method using Elekta log files and an X-ray voxel Monte Carlo dose calculation technique in the case of leaf misalignment during prostate volumetric-modulated arc therapy. In this study, 10 prostate volumetric-modulated arc therapy plans were used. Systematic multileaf collimator leaf positional errors (±0.4 and ±0.8 mm for each single bank) were deliberately introduced into the optimized plans. Then, the delivered 3-dimensional doses to a phantom with a certain patient anatomy were estimated by our system. These doses were compared with the ionization chamber dose and the ArcCHECK-3DVH dose. For the given phantom and patient anatomy, the estimated dose strongly coincided with the ionization chamber/ArcCHECK-3DVH dose ( P < .01). In addition, good agreement between the estimated dose and the ionization chamber/ArcCHECK-3DVH dose was observed. The dose estimation accuracy of our system, which combines Elekta log files and X-ray voxel Monte Carlo dose calculation, was evaluated.

  19. Radiotherapy and high-dose chemotherapy in advanced Ewing's tumors

    International Nuclear Information System (INIS)

    Pape, H.; Glag, M.; Gripp, S.; Wittkamp, M.; Schmitt, G.; Laws, H.J.; Kaik, B. van; Goebel, U.; Burdach, S.; Juergens, H.

    1999-01-01

    Background: Ewing's tumors are sensitive to radio- and chemotherapy. Patients with multifocal disease suffer a poor prognosis. Patients presenting primary bone marrow involvement or bone metastases at diagnosis herald a 3-year disease-free survival below 15%. The European Intergroup Cooperative Ewing's Sarcoma Study (EICESS) has established the following indications for high-dose therapy in advanced Ewing's tumors: Patients with primary multifocal bone disease, patients with early ( [de

  20. High-Dose Adjuvant Radiotherapy After Radical Prostatectomy With or Without Androgen Deprivation Therapy

    International Nuclear Information System (INIS)

    Ost, Piet; Cozzarini, Cesare; De Meerleer, Gert; Fiorino, Claudio; De Potter, Bruno; Briganti, Alberto; Nagler, Evi V.T.; Montorsi, Francesco; Fonteyne, Valérie; Di Muzio, Nadia

    2012-01-01

    Purpose: To retrospectively evaluate the outcome and toxicity in patients receiving high-dose (>69 Gy) adjuvant radiotherapy (HD-ART) and the impact of androgen deprivation therapy (ADT). Methods and Materials: Between 1999 and 2008, 225 node-negative patients were referred for HD-ART with or without ADT to two large academic institutions. Indications for HD-ART were extracapsular extension, seminal vesicle invasion (SVI), and/or positive surgical margins at radical prostatectomy (RP). A dose of at least 69.1 Gy was prescribed to the prostate bed and seminal vesicle bed. The ADT consisted of a luteinizing hormone–releasing hormone analog. The duration and indication of ADT was left at the discretion of the treating physician. The effect of HD-ART and ADT on biochemical (bRFS) and clinical (cRFS) relapse-free survival was examined through univariate and multivariate analysis, with correction for known patient- and treatment-related variables. Interaction terms were introduced to evaluate effect modification. Results: After a median follow-up time of 5 years, the 7-year bRFS and cRFS were 84% and 88%, respectively. On multivariate analysis, the addition of ADT was independently associated with an improved bRFS (hazard ratio [HR] 0.4, p = 0.02) and cRFS (HR 0.2, p = 0.008). Higher Gleason scores and SVI were associated with decreased bRFS and cRFS. A lymphadenectomy at the time of RP independently improved cRFS (HR 0.09, p = 0.009). The 7-year probability of late Grade 2–3 toxicity was 29% and 5% for genitourinary (GU) and gastrointestinal (GI) symptoms, respectively. The absolute incidence of Grade 3 toxicity was <1% and 10% for GI and GU symptoms, respectively. The study is limited by its retrospective design and the lack of a standardized use of ADT. Conclusions: This retrospective study shows significantly improved bRFS and cRFS rates with the addition of ADT to HD-ART, with low Grade 3 gastrointestinal toxicity and 10% Grade 3 genitourinary toxicity.

  1. Dose modification factors in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Allen, B.J. (Australian Nuclear Science and Technology Organization (ANSTO), Menai (Australia))

    1993-01-01

    The effective treatment depth and therapeutic ratio in boron neutron capture therapy (BNCT) depend on a number of macroscopic dose factors such as boron concentrations in the tumor, normal tissue and blood. However, the role of various microscopic dose modification factors can be of critical importance in the evaluation of normal tissue tolerance levels. An understanding of these factors is valuable in designing BNCT experiments and the selection of appropriate boron compounds. These factors are defined in this paper and applied to the case of brain tumors with particular attention to capillary endothelial cells and oligodendrocytes. (orig.).

  2. Intracavitary irradiation of prostatic carcinoma by a high dose-rate afterloading technique

    Energy Technology Data Exchange (ETDEWEB)

    Odelberg-Johnson, O.; Underskog, I.; Johansson, J.E.; Bernshaw, D.; Sorbe, B.; Persson, J.E. (Oerebro Medical Center Hospital (Sweden). Dept. of Oncology Oerebro Medical Center Hospital (Sweden). Dept. of Urology Oerebro Medical Center Hospital (Sweden). Dept. of Gynecologic Oncology Oerebro Medical Center Hospital (Sweden). Dept. of Radiation Physics)

    1991-01-01

    A high dose-rate ({sup 60}Co) afterloading technique was evaluated in a series of 73 patients with prostatic carcinoma stages I-IV. The intraurethral irradiation was combined with external pelvic radiotherapy. A minimum total dose of 78 Gy was delivered to the target volume. In a subgroup of patients extramustine (Estracyt) was given as adjuvant chemohormonal therapy during irradiation. The median follow-up for the whole group was 63 months. The crude 5-year survival rate was 60% and the corrected survival rate 90%. Survival was related to the tumor grade. Local pelvic recurrences were recorded in 17.8%. 'Viable cells' in posttherapy aspiration biopsy were not associated with tumor recurrences or survival. Four patients (5%) had grade 3 late radiation reactions with urethral structure or bladder fibrosis. Urinary tract infections and prior transurethral resections were not associated with a higher frequency of reactions. Concurrent estramustine therapy seemed to increase the frequency of both acute and chronic radiation reactions. Local control, recurrence, and survival were not affected by chemohormonal therapy. The use of tomography, magnetic resonance, and ultrasound as aids to computerized dosimetry may improve local dose distribution and reduce the irradiated volume. (orig.).

  3. Long term results of a prospective dose escalation phase-II trial: Interstitial pulsed-dose-rate brachytherapy as boost for intermediate- and high-risk prostate cancer

    International Nuclear Information System (INIS)

    Lettmaier, Sebastian; Lotter, Michael; Kreppner, Stephan; Strnad, Annedore; Fietkau, Rainer; Strnad, Vratislav

    2012-01-01

    Purpose: We reviewed our seven year single institution experience with pulsed dose rate brachytherapy dose escalation study in patients with intermediate and high risk prostate cancer. Materials and methods: We treated a total of 130 patients for intermediate and high risk prostate cancer at our institution between 2000 and 2007 using PDR-brachytherapy as a boost after conformal external beam radiation therapy to 50.4 Gy. The majority of patients had T2 disease (T1c 6%, T2 75%, T3 19%). Seventy three patients had intermediate-risk and 53 patients had high-risk disease according to the D’Amico classification. The dose of the brachytherapy boost was escalated from 25 to 35 Gy – 33 pts. received 25 Gy (total dose 75 Gy), 63 pts. 30 Gy (total dose 80 Gy) and 34 pts. 35 Gy, (total dose 85 Gy) given in one session (dose per pulse was 0.60 Gy or 0.70 Gy/h, 24 h per day, night and day, with a time interval of 1 h between two pulses). PSA-recurrence-free survival according to Kaplan–Meier using the Phoenix definition of biochemical failure was calculated and also late toxicities according to Common Toxicity Criteria scale were assessed. Results: At the time of analysis with a median follow-up of 60 months biochemical control was achieved by 88% of patients – only 16/130 patients (12.3%) developed a biochemical relapse. Biochemical relapse free survival calculated according to Kaplan–Meier for all patients at 5 years was 85.6% (83.9% for intermediate-risk patients and 84.2% for high-risk patients) and at 9 years’ follow up it was 79.0%. Analysing biochemical relapse free survival separately for different boost dose levels, at 5 years it was 97% for the 35 Gy boost dose and 82% for the 25 and 30 Gy dose levels. The side effects of therapy were negligible: There were 18 cases (15%) of grade 1/2 rectal proctitis, one case (0.8%) of grade 3 proctitis, 18 cases (15%) of grade 1/2 cystitis, and no cases (0%) with dysuria grade 3. No patient had a bulbourethral

  4. High dose sapropterin dihydrochloride therapy improves monoamine neurotransmitter turnover in murine phenylketonuria (PKU).

    Science.gov (United States)

    Winn, Shelley R; Scherer, Tanja; Thöny, Beat; Harding, Cary O

    2016-01-01

    Central nervous system (CNS) deficiencies of the monoamine neurotransmitters, dopamine and serotonin, have been implicated in the pathophysiology of neuropsychiatric dysfunction in phenylketonuria (PKU). Increased brain phenylalanine concentration likely competitively inhibits the activities of tyrosine hydroxylase (TH) and tryptophan hydroxylase (TPH), the rate limiting steps in dopamine and serotonin synthesis respectively. Tetrahydrobiopterin (BH4) is a required cofactor for TH and TPH activity. Our hypothesis was that treatment of hyperphenylalaninemic Pah(enu2/enu2) mice, a model of human PKU, with sapropterin dihydrochloride, a synthetic form of BH4, would stimulate TH and TPH activities leading to improved dopamine and serotonin synthesis despite persistently elevated brain phenylalanine. Sapropterin (20, 40, or 100mg/kg body weight in 1% ascorbic acid) was administered daily for 4 days by oral gavage to Pah(enu2/enu2) mice followed by measurement of brain biopterin, phenylalanine, tyrosine, tryptophan and monoamine neurotransmitter content. A significant increase in brain biopterin content was detected only in mice that had received the highest sapropterin dose, 100mg/kg. Blood and brain phenylalanine concentrations were unchanged by sapropterin therapy. Sapropterin therapy also did not alter the absolute amounts of dopamine and serotonin in brain but was associated with increased homovanillic acid (HVA) and 5-hydroxyindoleacetic acid (5-HIAA), dopamine and serotonin metabolites respectively, in both wild type and Pah(enu2/enu2) mice. Oral sapropterin therapy likely does not directly affect central nervous system monoamine synthesis in either wild type or hyperphenylalaninemic mice but may stimulate synaptic neurotransmitter release and subsequent metabolism. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. A Clinical phase I/II trial to investigate preoperative dose-escalated intensity-modulated radiation therapy (IMRT and intraoperative radiation therapy (IORT in patients with retroperitoneal soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Roeder Falk

    2012-07-01

    Full Text Available Abstract Background Local control rates in patients with retroperitoneal soft tissue sarcoma (RSTS remain disappointing even after gross total resection, mainly because wide margins are not achievable in the majority of patients. In contrast to extremity sarcoma, postoperative radiation therapy (RT has shown limited efficacy due to its limitations in achievable dose and coverage. Although Intraoperative Radiation Therapy (IORT has been introduced in some centers to overcome the dose limitations and resulted in increased outcome, local failure rates are still high even if considerable treatment related toxicity is accepted. As postoperative administration of RT has some general disadvantages, neoadjuvant approaches could offer benefits in terms of dose escalation, target coverage and reduction of toxicity, especially if highly conformal techniques like intensity-modulated radiation therapy (IMRT are considered. Methods/design The trial is a prospective, one armed, single center phase I/II study investigating a combination of neoadjuvant dose-escalated IMRT (50–56 Gy followed by surgery and IORT (10–12 Gy in patients with at least marginally resectable RSTS. The primary objective is the local control rate after five years. Secondary endpoints are progression-free and overall survival, acute and late toxicity, surgical resectability and patterns of failure. The aim of accrual is 37 patients in the per-protocol population. Discussion The present study evaluates combined neoadjuvant dose-escalated IMRT followed by surgery and IORT concerning its value for improved local control without markedly increased toxicity. Trial registration NCT01566123

  6. A Clinical phase I/II trial to investigate preoperative dose-escalated intensity-modulated radiation therapy (IMRT) and intraoperative radiation therapy (IORT) in patients with retroperitoneal soft tissue sarcoma

    International Nuclear Information System (INIS)

    Roeder, Falk; Hensley, Frank W; Buechler, Markus W; Debus, Juergen; Koch, Moritz; Weitz, Juergen; Bischof, Marc; Schulz-Ertner, Daniela; Nikoghosyan, Anna V; Huber, Peter E; Edler, Lutz; Habl, Gregor; Krempien, Robert; Oertel, Susanne; Saleh-Ebrahimi, Ladan

    2012-01-01

    Local control rates in patients with retroperitoneal soft tissue sarcoma (RSTS) remain disappointing even after gross total resection, mainly because wide margins are not achievable in the majority of patients. In contrast to extremity sarcoma, postoperative radiation therapy (RT) has shown limited efficacy due to its limitations in achievable dose and coverage. Although Intraoperative Radiation Therapy (IORT) has been introduced in some centers to overcome the dose limitations and resulted in increased outcome, local failure rates are still high even if considerable treatment related toxicity is accepted. As postoperative administration of RT has some general disadvantages, neoadjuvant approaches could offer benefits in terms of dose escalation, target coverage and reduction of toxicity, especially if highly conformal techniques like intensity-modulated radiation therapy (IMRT) are considered. The trial is a prospective, one armed, single center phase I/II study investigating a combination of neoadjuvant dose-escalated IMRT (50–56 Gy) followed by surgery and IORT (10–12 Gy) in patients with at least marginally resectable RSTS. The primary objective is the local control rate after five years. Secondary endpoints are progression-free and overall survival, acute and late toxicity, surgical resectability and patterns of failure. The aim of accrual is 37 patients in the per-protocol population. The present study evaluates combined neoadjuvant dose-escalated IMRT followed by surgery and IORT concerning its value for improved local control without markedly increased toxicity. NCT01566123

  7. In vitro antibacterial activity of rifampicin in combination with imipenem, meropenem and doripenem against multidrug-resistant clinical isolates of Pseudomonas aeruginosa.

    Science.gov (United States)

    Hu, Yi-Fan; Liu, Chang-Pan; Wang, Nai-Yu; Shih, Shou-Chuan

    2016-08-24

    Multidrug-resistant Pseudomonas aeruginosa has emerged as one of the most important healthcare-associated pathogens. Colistin is regarded as the last-resort antibiotic for multidrug-resistant Gram-negative bacteria, but is associated with high rates of acute kidney injury. The aim of this in vitro study is to search for an alternative treatment to colistin for multidrug-resistant P. aeruginosa infections. Multidrug and carbapenem-resistant P. aeruginosa isolates were collected between January 2009 and December 2012 at MacKay Memorial Hospital. Minimal inhibitory concentrations (MICs) were determined for various antibiotic combinations. Carbapenemase-producing genes including bla VIM, other β-lactamase genes and porin mutations were screened by PCR and sequencing. The efficacy of carbapenems (imipenem, meropenem, doripenem) with or without rifampicin was correlated with the type of porin mutation (frameshift mutation, premature stop codon mutation) in multidrug-resistant P. aeruginosa isolates without carbapenemase-producing genes. Of the 71 multidrug-resistant clinical P. aeruginosa isolates, only six harboured the bla VIM gene. Imipenem, meropenem and doripenem were significantly more effective (reduced fold-change of MICs) when combined with rifampicin in bla VIM-negative isolates, especially in isolates with porin frameshift mutation. Imipenem + rifampicin combination has a low MIC against multidrug-resistant P. aeruginosa, especially in isolates with porin frameshift mutation. The imipenem + rifampicin combination may provide an alternative treatment to colistin for multidrug -resistant P. aeruginosa infections, especially for patients with renal insufficiency.

  8. Long-Term Outcomes After High-Dose Postprostatectomy Salvage Radiation Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Goenka, Anuj; Magsanoc, Juan Martin; Pei Xin; Schechter, Michael; Kollmeier, Marisa; Cox, Brett [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Scardino, Peter T.; Eastham, James A. [Urology Service, Department of Surgery, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Zelefsky, Michael J., E-mail: zelefskm@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2012-09-01

    Purpose: To review the impact of high-dose radiotherapy (RT) in the postprostatectomy salvage setting on long-term biochemical control and distant metastases-free survival, and to identify clinical and pathologic predictors of outcomes. Methods and Materials: During 1988-2007, 285 consecutive patients were treated with salvage RT (SRT) after radical prostatectomy. All patients were treated with either three-dimensional conformal RT or intensity-modulated RT. Two hundred seventy patients (95%) were treated to a dose {>=}66 Gy, of whom 205 (72%) received doses {>=}70 Gy. Eighty-seven patients (31%) received androgen-deprivation therapy as a component of their salvage treatment. All clinical and pathologic records were reviewed to identify treatment risk factors and response. Results: The median follow-up time after SRT was 60 months. Seven-year actuarial prostate-specific antigen (PSA) relapse-free survival and distant metastases-free survival were 37% and 77%, respectively. Independent predictors of biochemical recurrence were vascular invasion (p < 0.01), negative surgical margins (p < 0.01), presalvage PSA level >0.4 ng/mL (p < 0.01), androgen-deprivation therapy (p = 0.03), Gleason score {>=}7 (p = 0.02), and seminal vesicle involvement (p = 0.05). Salvage RT dose {>=}70 Gy was not associated with improvement in biochemical control. A doubling time <3 months was the only independent predictor of metastatic disease (p < 0.01). There was a trend suggesting benefit of SRT dose {>=}70 Gy in preventing clinical local failure in patients with radiographically visible local disease at time of SRT (7 years: 90% vs. 79.1%, p = 0.07). Conclusion: Salvage RT provides effective long-term biochemical control and freedom from metastasis in selected patients presenting with detectable PSA after prostatectomy. Androgen-deprivation therapy was associated with improvement in biochemical progression-free survival. Clinical local failures were rare but occurred most commonly in

  9. Superselective intra-arterial infusion of high-dose cisplatin combined with radiation therapy for head and neck carcinoma. Experience of Yamagata University Hospital

    International Nuclear Information System (INIS)

    Hamamoto, Yasushi; Niino, Keiji; Ishiyama, Hiromichi; Koike, Shuji; Hosoya, Takaaki; Aoyagi, Masaru

    2003-01-01

    Local effectiveness and complication of superselective intra-arterial infusion of high-dose cisdiamminedichloroplatinum (CDDP) (SIC) combined with radiation therapy (RT) were investigated. Between 1998 and 2000, 18 head and neck carcinomas including 10 maxillary carcinomas (T3; 1, T4; 9), 3 oral cavity carcinomas (T2; 1, T4; 2), and 5 oropharyngeal carcinomas (T2; 2, T4; 3) were treated with SIC and RT with or without surgery. CDDP of 100-150 mg/body was administered weekly in principle for 2-9 weeks (mean: 4.9) with the simultaneous administration of sodium thiosulfate. Radiation doses ranged from 40 Gy to 70 Gy (mean: 56.8 Gy). Complete response was obtained in 7 of 10 maxillary carcinomas, 2 of 3 oral-cavity carcinomas, and 2 of 5 oropharyngeal carcinomas, respectively. When surgical intervention was performed if necessary, 2-year local control rates for maxillary carcinoma, and other carcinoma including oral-cavity carcinoma and oropharyngeal carcinoma were 80% and 63% respectively. Two-year local control rates for T4 maxillary carcinoma, and other T4 carcinoma including oral-cavity carcinoma and oropharyngeal carcinoma were 78% and 40% respectively. Two-year overall survival rates for all cases, maxillary carcinoma, and oral-cavity/oropharyngeal carcinoma were 88%, 90% and 86% respectively. All local recurrences occurred within 6 months from the initiation of treatment. The systemic toxicity of weekly SIC was comparatively mild; however, a total CDDP dose of 1,000 mg or more and/or RT of 70 Gy induced complications of local soft tissue such as mucosal ulcer and fistula. SIC combined with RT is useful to improve the local control/survival rates and to avoid the aggressive surgery for locally advanced head and neck carcinoma. A high total dose of CDDP and/or RT of a comparatively high dose may be risk factors for local soft tissue complications. (author)

  10. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids

    DEFF Research Database (Denmark)

    Jiang, Ping; Baumann, René; Dunst, Jürgen

    2016-01-01

    PURPOSE: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. METHODS AND MATERIALS: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immed...

  11. Salvage high-dose-rate brachytherapy for local prostate cancer recurrence after radical radiotherapy

    Directory of Open Access Journals (Sweden)

    V. A. Solodkiy

    2016-01-01

    Full Text Available Studies salvage interstitial radiation therapy for recurrent prostate cancer, launched at the end of the XX century. In recent years, more and more attention is paid to high-dose-rate brachytherapy (HDR-BT as a method of treating local recurrence.The purpose of research – preliminary clinical results of salvage high-dose-rate brachytherapy applied in cases of suspected local recurrence or of residual tumour after radiotherapy.Preliminary findings indicate the possibility of using HDR-BT, achieving local tumor control with low genitourinary toxicity.

  12. Myelotoxicity after high-dose methotrexate in childhood acute leukemia is influenced by 6-mercaptopurine dosing but not by intermediate thiopurine methyltransferase activity

    DEFF Research Database (Denmark)

    Levinsen, Mette; Rosthøj, Susanne; Nygaard, Ulrikka

    2015-01-01

    Purpose: Through enhancement of 6-mercaptopurine (6MP) bioavailability and inhibition of purine de novo synthesis, high-dose methotrexate (HD-MTX) may increase incorporation into DNA of 6-thioguanine nucleotides, the cytotoxic metabolites of 6MP. Patients with intermediate activity of thiopurine...... methyltransferase (TPMTIA) have higher cytosol 6-thioguanine nucleotide levels. We investigated toxicity following HD-MTX during MTX/6MP maintenance therapy in relation to 6MP and TPMT. Methods: Using linear mixed models, we explored myelo- and hepatotoxicity in relation to 6MP dosage and TPMT phenotype following 1......,749 HD-MTX courses to 411 children with acute lymphoblastic leukemia on maintenance therapy. Results: The degree of myelosuppression following HD-MTX was similar for patients with TPMTIA and patients with high TPMT activity (TPMTHA), when HD-MTX started with same blood counts and 6MP doses. However...

  13. Repeated dose titration versus age-based method in electroconvulsive therapy: a pilot study

    NARCIS (Netherlands)

    Aten, J.J.; Oudega, M.L.; van Exel, E.; Stek, M.L.; van Waarde, J.A.

    2015-01-01

    In electroconvulsive therapy (ECT), a dose titration method (DTM) was suggested to be more individualized and therefore more accurate than formula-based dosing methods. A repeated DTM (every sixth session and dose adjustment accordingly) was compared to an age-based method (ABM) regarding treatment

  14. Damage control resuscitation using blood component therapy in standard doses has a limited effect on coagulopathy during trauma hemorrhage.

    Science.gov (United States)

    Khan, Sirat; Davenport, Ross; Raza, Imran; Glasgow, Simon; De'Ath, Henry D; Johansson, Pär I; Curry, Nicola; Stanworth, Simon; Gaarder, Christine; Brohi, Karim

    2015-02-01

    To determine the effectiveness of blood component therapy in the correction of trauma-induced coagulopathy during hemorrhage. Severe hemorrhage remains a leading cause of mortality in trauma. Damage control resuscitation strategies target trauma-induced coagulopathy (TIC) with the early delivery of high-dose blood components such as fresh frozen plasma (FFP) and platelet transfusions. However, the ability of these products to correct TIC during hemorrhage and resuscitation is unknown. This was an international prospective cohort study of bleeding trauma patients at three major trauma centers. A blood sample was drawn immediately on arrival and after 4, 8 and 12 packed red blood cell (PRBC) transfusions. FFP, platelet and cryoprecipitate use was recorded during these intervals. Samples were analyzed for functional coagulation and procoagulant factor levels. One hundred six patients who received at least four PRBC units were included. Thirty-four patients (32 %) required a massive transfusion. On admission 40 % of patients were coagulopathic (ROTEM CA5 ≤ 35 mm). This increased to 58 % after four PRBCs and 81 % after eight PRBCs. On average all functional coagulation parameters and procoagulant factor concentrations deteriorated during hemorrhage. There was no clear benefit to high-dose FFP therapy in any parameter. Only combined high-dose FFP, cryoprecipitate and platelet therapy with a high total fibrinogen load appeared to produce a consistent improvement in coagulation. Damage control resuscitation with standard doses of blood components did not consistently correct trauma-induced coagulopathy during hemorrhage. There is an important opportunity to improve TIC management during damage control resuscitation.

  15. SU-E-J-89: Motion Effects On Organ Dose in Respiratory Gated Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, T; Zhu, L [Georgia Institute of Technology, Atlanta, GA (Georgia); Khan, M; Landry, J; Rajpara, R; Hawk, N [Emory University, Atlanta, GA (United States)

    2014-06-01

    Purpose: Existing reports on gated radiation therapy focus mainly on optimizing dose delivery to the target structure. This work investigates the motion effects on radiation dose delivered to organs at risk (OAR) in respiratory gated stereotactic body radiation therapy (SBRT). A new algorithmic tool of dose analysis is developed to evaluate the optimality of gating phase for dose sparing on OARs while ensuring adequate target coverage. Methods: Eight patients with pancreatic cancer were treated on a phase I prospective study employing 4DCT-based SBRT. For each patient, 4DCT scans are acquired and sorted into 10 respiratory phases (inhale-exhale- inhale). Treatment planning is performed on the average CT image. The average CT is spatially registered to other phases. The resultant displacement field is then applied on the plan dose map to estimate the actual dose map for each phase. Dose values of each voxel are fitted to a sinusoidal function. Fitting parameters of dose variation, mean delivered dose and optimal gating phase for each voxel over respiration cycle are mapped on the dose volume. Results: The sinusoidal function accurately models the dose change during respiratory motion (mean fitting error 4.6%). In the eight patients, mean dose variation is 3.3 Gy on OARs with maximum of 13.7 Gy. Two patients have about 100cm{sup 3} volumes covered by more than 5 Gy deviation. The mean delivered dose maps are similar to plan dose with slight deformation. The optimal gating phase highly varies across the patient, with phase 5 or 6 on about 60% of the volume, and phase 0 on most of the rest. Conclusion: A new algorithmic tool is developed to conveniently quantify dose deviation on OARs from plan dose during the respiratory cycle. The proposed software facilitates the treatment planning process by providing the optimal respiratory gating phase for dose sparing on each OAR.

  16. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  17. High-precision radiosurgical dose delivery by interlaced microbeam arrays of high-flux low-energy synchrotron X-rays.

    Directory of Open Access Journals (Sweden)

    Raphaël Serduc

    Full Text Available Microbeam Radiation Therapy (MRT is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy. Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 microm wide, spaced 200 microm on-center, 50 to 350 keV in energy range, targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm(3 in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing

  18. High efficacy and safety from high dose 131I for the treatment of hyperthyroidism caused by Graves' disease (GD)

    International Nuclear Information System (INIS)

    Juri, A.; Pitoia, Fabian; El Tamer, Elias; Lopaczek, N.; Mana, D.; Niepomniszcze, Hugo

    2005-01-01

    Full text: Introduction: Radioiodine (RAI) 131 I has became a widely used therapy for patients with hyperthyroidism due to GD. It is controversial which the dose to apply in such patients is. Administration of low doses of 131 I, oriented to decrease the incidence of hypothyroidism, may delay or fail to cure the hyperthyroidism. Objective: We designed this study to compare the frequencies of cure and persistence/recidive (P/R) of the hyperthyroidism using 2 different fixed dose protocols, also to evaluate the presence of complications after such doses. Subjects and Methods: Seventy six patients who received 131 I therapy for GD between 1997 and 2004 were evaluated. All of them had received initial treatment with methimazole, relapsing the hyperthyroidism after drug withdrawal. Patients were divided into 2 groups considering the RAI dose administered. Group 1 (n=32): 300 μCi/g retained at 24 h; and Group 2 (n=44): 100 μCi/g retained at 24 h. Both groups were comparable when age, gender and thyroid weight were considered. Results: The frequency of cure was 87.5% (28/32) in Group 1 vs. 45.5% (20/44) in Group 2 (p<0.0003). Hypothyroidism was observed in 96.5% (27/28) of cured patients in Group 1 vs. 85% (17/20) of cured patients in Group 2 (p=NS). P/R was observed in 28 patients. Twenty five of them received a new RAI dose (3 in Group 1 and 22 in Group 2) and two had received a third dose. After this procedure 87.5 % became hypothyroid within one year of follow up. No adverse events were observed in these patients, except for hypothyroidism. Conclusion: High dose RAI therapy in GD resulted in earlier and better rates for the control of thyrotoxicosis. Rates of hypothyroidism were similar in both groups, with the difference that those subjects, who originally received a low dose of RAI, were creeping in a winding path, rendering a poor quality of life, and finally arriving at the same hypothyroid state than the others. Therefore, we recommend high RAI doses for the

  19. Dose finding study of granisetron in patients receiving high-dose cisplatin chemotherapy. The Granisetron Study Group.

    Science.gov (United States)

    Riviere, A.

    1994-01-01

    The efficacy and safety of three different doses of granisetron (2 micrograms kg-1, group A; 10 micrograms kg-1, group B; 40 micrograms kg-1, group C) were compared in a randomised, double-blind study of 157 patients due to receive high-dose cisplatin therapy (mean dose > 97 mg m-2). In each group, up to two 3 mg rescue doses of granisetron were allowed if more than mild nausea or vomiting occurred. In group A 30.8%, in group B 61.5% and in group C 67.9% of patients were complete responders (i.e. no vomiting or nothing worse than mild nausea) during the first 24 h. These differences are significant between groups A and B, and A and C. There were no statistically significant differences in any efficacy variable between the 10 micrograms kg-1 and 40 micrograms kg-1 groups, although in each case the trend favoured the higher dose. Additional rescue doses resulted in resolved or improved symptoms in 95.3% for the first rescue dose and 93.3% for the second. Over the 7 days of the study, 82.7%, 82.7% and 86.8% of patients in groups A, B and C respectively were treated with granisetron alone. Headache was the most common side-effect, reported by 9.6% of patients; the majority of headaches were mild. There was no difference between the treatment groups regarding the adverse event rate. We concluded that prophylactic doses of 10 or 40 micrograms kg-1 lead to a safe and satisfactory degree of control of nausea and vomiting induced by high-dose cisplatin. PMID:8180032

  20. Radiation absorbed dose and expected risk in head and neck tissues after thyroid radioiodine therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, A [National Center for Nuclear and Radiation Control, AEA., Cairo (Egypt); Farag, H I [National Cancer instiute, Cairo University, Cairo (Egypt); Saleh, A [Al-hussien Hospital, Al-Azhar University, Cairo (Egypt)

    1997-12-31

    Measurement of absorbed dose in head and neck phantom after applying I-131 therapeutic dose for the treatment of thyroid malignancies was conducted. The measurement were carried out at several sites of phantom using TL dosimeters. The absorbed doses were also measured on the skin of four patients during their administration of I-131 therapeutic doses 1.332 GBq (36 mci) I-131. The measurements were taken over 69 hours exposure at different sites of phantom. The same measurements were carried out on the four patients. At five sites of the patients head and neck, the absorbed dose were measured and compared with that measured on the phantom. The values measured are discussed in the light of the published individual absorbed doses in the organs by ICRP tables. High absorbed doses were absorbed in the different sites of the head and neck during the I-131 therapy (0.14-9.68 mGy/mCi). 3 figs., 2 tabs.

  1. The elementary discussion of volumetric modulated arc therapy using the orthogonal plane dose verification

    International Nuclear Information System (INIS)

    Shi Jinping; Chen Lixin; Xie Qiuying; Zhang Liwen; Teng Jianjian

    2012-01-01

    Objective: This study was to explore the feasibility of using the orthogonal plane dose formed by the coronal and sagittal plane to verify the volumetric modulated arc therapy (VMAT) plan. Methods: The VMAT plans of 12 patients were included in this study. The orthogonal plane dose formed by the coronal and sagittal plane were measured based on the combination of 2D ionization chamber array and multicube phantom, and the point dose were measured based on a multiple hole cylindrical phantom attached with two 0.125 cm 3 ionization chamber probes. Results: In the measurement of the point dose, the average error was 1.5% in high dose area (more than 80% of maximum), and 1.7% in low dose area (less than 80% of maximum), respectively. The discrepancy of point dose measurement was 1.3% between the 2D ionization chamber array and the VMAT planning system. In the measurement of the orthogonal plane dose, the pass rate of γ were 93.7% for 2%/2 mm and 97.2% for 3%/3 mm. Conclusion: It is reliable for using the orthogonal plane dose formed by the coronal and sagittal plane to verify the VMAT plan. (authors)

  2. Use of high-dose, twice-yearly albendazole and ivermectin to suppress Wuchereria bancrofti microfilarial levels.

    Science.gov (United States)

    Dembele, Benoit; Coulibaly, Yaya I; Dolo, Housseini; Konate, Siaka; Coulibaly, Siaka Y; Sanogo, Dramane; Soumaoro, Lamine; Coulibaly, Michel E; Doumbia, Salif Seriba; Diallo, Abdallah A; Traore, Sekou F; Diaman Keita, Adama; Fay, Michael P; Nutman, Thomas B; Klion, Amy D

    2010-12-01

    Annual mass treatment with albendazole and ivermectin is the mainstay of current strategies to interrupt transmission of Wuchereria bancrofti in Africa. More-effective microfilarial suppression could potentially reduce the time necessary to interrupt transmission, easing the economic burden of mass treatment programs in countries with limited resources. To determine the effect of increased dose and frequency of albendazole-ivermectin treatment on microfilarial clearance, 51 W. bancrofti microfilaremic residents of an area of W. bancrofti endemicity in Mali were randomized to receive 2 doses of annual, standard-dose albendazole-ivermectin therapy (400 mg and 150 μg/kg; n = 26) or 4 doses of twice-yearly, increased-dose albendazole-ivermectin therapy (800 mg and 400 μg/kg; n = 25). Although microfilarial levels decreased significantly after therapy in both groups, levels were significantly lower in the high-dose, twice-yearly group at 12, 18, and 24 months. Furthermore, there was complete clearance of detectable microfilariae at 12 months in the 19 patients in the twice-yearly therapy group with data available at 12 months, compared with 9 of 21 patients in the annual therapy group (P < .001, by Fisher's exact test). This difference between the 2 groups was sustained at 18 and 24 months, with no detectable microfilariae in the patients receiving twice-yearly treatment. Worm nests detectable by ultrasonography and W. bancrofti circulating antigen levels, as measured by enzyme-linked immunosorbent assay, were decreased to the same degree in both groups at 24 months, compared with baseline. These findings suggest that increasing the dosage and frequency of albendazole-ivermectin treatment enhances suppression of microfilariae but that this effect may not be attributable to improved adulticidal activity.

  3. High dose rate versus low dose rate interstitial radiotherapy for carcinoma of the floor of mouth

    International Nuclear Information System (INIS)

    Inoue, Takehiro; Inoue, Toshihiko; Yamazaki, Hideya; Koizumi, Masahiko; Kagawa, Kazufumi; Yoshida, Ken; Shiomi, Hiroya; Imai, Atsushi; Shimizutani, Kimishige; Tanaka, Eichii; Nose, Takayuki; Teshima, Teruki; Furukawa, Souhei; Fuchihata, Hajime

    1998-01-01

    Purpose: Patients with cancer of the floor of mouth are treated with radiation because of functional and cosmetic reasons. We evaluate the treatment results of high dose rate (HDR) and low dose rate (LDR) interstitial radiation for cancer of the floor of mouth. Methods and Materials: From January 1980 through March 1996, 41 patients with cancer of the floor of mouth were treated with LDR interstitial radiation using 198 Au grains, and from April 1992 through March 1996 16 patients with HDR interstitial radiation. There were 26 T1 tumors, 30 T2 tumors, and 1 T3 tumor. For 21 patients treated with interstitial radiation alone, a total radiation dose of interstitial therapy was 60 Gy/10 fractions/6-7 days in HDR and 85 Gy within 1 week in LDR. For 36 patients treated with a combination therapy, a total dose of 30 to 40 Gy of external radiation and a total dose of 48 Gy/8 fractions/5-6 days in HDR or 65 Gy within 1 week in LDR were delivered. Results: Two- and 5-year local control rates of patients treated with HDR interstitial radiation were 94% and 94%, and those with LDR were 75% and 69%, respectively. Local control rate of patients treated with HDR brachytherapy was slightly higher than that with 198 Au grains (p = 0.113). For late complication, bone exposure or ulcer occurred in 6 of 16 (38%) patients treated with HDR and 13 of 41 (32%) patients treated with LDR. Conclusion: HDR fractionated interstitial brachytherapy can be an alternative to LDR brachytherapy for cancer of the floor of mouth and eliminate radiation exposure for the medical staff

  4. Long-term follow-up study of compensated low-dose 131I therapy for Graves' disease

    International Nuclear Information System (INIS)

    Sridama, V.; McCormick, M.; Kaplan, E.L.; Fauchet, R.; DeGroot, L.J.

    1984-01-01

    We treated 187 patients who had Graves' disease with low-dose radioactive iodide ( 131 I), using a protocol that included a compensation for thyroid size. The incidence of early hypothyroidism (12 per cent) was acceptably low in the first year after 131 I treatment, but we found a cumulative high incidence (up to 76 per cent) at the end of the 11th year. In contrast, the incidence of permanent hypothyroidism was relatively stable in 166 surgically treated patients, increasing from 19 to 27 per cent at the end of 11 years. Among 122 medically treated patients, only 40 per cent entered remission, and hypothyroidism developed in 2 per cent during the same period of follow-up. The long-term incidence of hypothyroidism in our patients treated with low-dose 131 I therapy was much higher than that found in earlier studies using a comparable dose. Our study suggests that it will be difficult to modify therapy with 131 I alone to produce both early control of thyrotoxicosis and a low incidence of hypothyroidism

  5. High-dose radiation therapy alone for inoperable non-small cell lung cancer. Experience with prolonged overall treatment times

    International Nuclear Information System (INIS)

    Willers, H.; Wuerschmidt, F.; Buenemann, H.; Heilmann, H.P.

    1998-01-01

    The purpose of this study was to determine the impact of overall treatment time on long-term survival after high-dose radiation therapy alone for inoperable non-small cell lung cancer (NSCLC). Between 1978 and 1990, 229 patients with stage I-III disease and Karnofsky Performance Scores of 80-100 received a conventionally fractionated total dose of 70 Gy through a split-course technique. After a first treatment course of 40 or 50 Gy, a rest aging was performed and only patients without any contraindications, such as newly diagnosed distant metastases or serious deterioration of performance status, were given a second course. In 83% of patients this break lasted for 4-6 weeks. Overall treatment time ranged between 7 and 24 weeks (median 12 weeks). Median follow-up time was 6.6 years (range 4.0-9.3 years). Actuarial overall survival rates at 2 and 5 years were 28% and 7% respectively. Complete radiological tumor response was observed in 31% of patients, and was found to be the strongest positive predictor of survival with 2- and 5-year rates of 50% and 12% respectively compared with 17% and 4% for patients without complete response. Treatment duration was not found to be a significant prognostic factor in univariate or multivariate analysis. For overall treatment times of 7-11 weeks (n=50), 12 weeks (n=79) and >12 weeks (n=100), 5-year survival was 4%, 6%, and 8%, respectively (p=0.6). To conclude, in our experience and in contrast to other studies, prolonged overall treatment times in radiation therapy alone for inoperable NSCLC had no negative impact on long-term survival. It is hypothesized that accelerated tumor cell repopulation is absent in a significant number of these patients with the time-factor playing no apparent role for outcome of treatment. (orig.)

  6. Treatment planning and dose analysis for interstitial photodynamic therapy of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, Sean R H; Gertner, Mark R; Bogaards, Arjen; Sherar, Michael D; Wilson, Brian C [Division of Biophysics and Bioimaging, Ontario Cancer Institute, University Health Network, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Weersink, Robert A; Giewercer, David [Laboratory for Applied Biophysics, Ontario Cancer Institute, University Health Network, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A [Joint Department of Medical Imaging, University Health Network, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada); Scherz, Avigdor [Department of Plant Science, Weizmann Institute of Science, PO Box 26, Rehovot 76100 (Israel); Elhilali, Mostafa [Department of Surgery, McGill University, 3655 Promenade Sir William Osler, Montreal, Quebec H3G 1Y6 (Canada); Chin, Joseph L [Department of Oncology, University of Western Ontario, 800 Commissioners Road East, PO Box 5010, London, Ontario N6A 5W9 (Canada); Trachtenberg, John [Department of Urology, University Health Network, 610 University Avenue, Toronto, Ontario M5G 2M9 (Canada)], E-mail: wilson@uhnres.utoronto.ca

    2009-04-21

    With the development of new photosensitizers that are activated by light at longer wavelengths, interstitial photodynamic therapy (PDT) is emerging as a feasible alternative for the treatment of larger volumes of tissue. Described here is the application of PDT treatment planning software developed by our group to ensure complete coverage of larger, geometrically complex target volumes such as the prostate. In a phase II clinical trial of TOOKAD vascular targeted photodynamic therapy (VTP) for prostate cancer in patients who failed prior radiotherapy, the software was used to generate patient-specific treatment prescriptions for the number of treatment fibres, their lengths, their positions and the energy each delivered. The core of the software is a finite element solution to the light diffusion equation. Validation against in vivo light measurements indicated that the software could predict the location of an iso-fluence contour to within approximately {+-}2 mm. The same software was used to reconstruct the treatments that were actually delivered, thereby providing an analysis of the threshold light dose required for TOOKAD-VTP of the post-irradiated prostate. The threshold light dose for VTP-induced prostate damage, as measured one week post-treatment using contrast-enhanced MRI, was found to be highly heterogeneous, both within and between patients. The minimum light dose received by 90% of the prostate, D{sub 90}, was determined from each patient's dose-volume histogram and compared to six-month sextant biopsy results. No patient with a D{sub 90} less than 23 J cm{sup -2} had complete biopsy response, while 8/13 (62%) of patients with a D{sub 90} greater than 23 J cm{sup -2} had negative biopsies at six months. The doses received by the urethra and the rectal wall were also investigated.

  7. Local dose enhancement in radiation therapy: Monte Carlo simulation study; Reforco local de dose em radioterapia utilizando nanoparticulas: estudo por simulacao Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Laura E. da; Nicolucci, Patricia, E-mail: laura.emilia.fm@gmail.com [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras

    2014-04-15

    The development of nanotechnology has boosted the use of nanoparticles in radiation therapy in order to achieve greater therapeutic ratio between tumor and healthy tissues. Gold has been shown to be most suitable to this task due to the high biocompatibility and high atomic number, which contributes to a better in vivo distribution and for the local energy deposition. As a result, this study proposes to study, nanoparticle in the tumor cell. At a range of 11 nm from the nanoparticle surface, results have shown an absorbed dose 141 times higher for the medium with the gold nanoparticle compared to the water for an incident energy spectrum with maximum photon energy of 50 keV. It was also noted that when only scattered radiation is interacting with the gold nanoparticles, the dose was 134 times higher compared to enhanced local dose that remained significant even for scattered radiation. (author)

  8. An automated dose tracking system for adaptive radiation therapy.

    Science.gov (United States)

    Liu, Chang; Kim, Jinkoo; Kumarasiri, Akila; Mayyas, Essa; Brown, Stephen L; Wen, Ning; Siddiqui, Farzan; Chetty, Indrin J

    2018-02-01

    The implementation of adaptive radiation therapy (ART) into routine clinical practice is technically challenging and requires significant resources to perform and validate each process step. The objective of this report is to identify the key components of ART, to illustrate how a specific automated procedure improves efficiency, and to facilitate the routine clinical application of ART. Data was used from patient images, exported from a clinical database and converted to an intermediate format for point-wise dose tracking and accumulation. The process was automated using in-house developed software containing three modularized components: an ART engine, user interactive tools, and integration tools. The ART engine conducts computing tasks using the following modules: data importing, image pre-processing, dose mapping, dose accumulation, and reporting. In addition, custom graphical user interfaces (GUIs) were developed to allow user interaction with select processes such as deformable image registration (DIR). A commercial scripting application programming interface was used to incorporate automated dose calculation for application in routine treatment planning. Each module was considered an independent program, written in C++or C#, running in a distributed Windows environment, scheduled and monitored by integration tools. The automated tracking system was retrospectively evaluated for 20 patients with prostate cancer and 96 patients with head and neck cancer, under institutional review board (IRB) approval. In addition, the system was evaluated prospectively using 4 patients with head and neck cancer. Altogether 780 prostate dose fractions and 2586 head and neck cancer dose fractions went processed, including DIR and dose mapping. On average, daily cumulative dose was computed in 3 h and the manual work was limited to 13 min per case with approximately 10% of cases requiring an additional 10 min for image registration refinement. An efficient and convenient

  9. ZTI-01 Treatment Improves Survival of Animals Infected with Multidrug Resistant Pseudomonas aeruginosa

    Science.gov (United States)

    Lawrenz, Matthew B; denDekker, Ashley Eb; Cramer, Daniel E; Gabbard, Jon D; Lafoe, Kathryn M; Pfeffer, Tia L; Sotsky, Julie B; Vanover, Carol D; Ellis-Grosse, Evelyn J; Warawa, Jonathan M

    2017-01-01

    Abstract Background ZTI-01 (fosfomycin, FOS, for injection) is currently under US development to treat complicated urinary tract infections. ZTI-01 is unique compared with other antimicrobials in that it inhibits an early step in cell wall synthesis via covalent binding to MurA. ZTI-01 demonstrates broad in vitro activity against Gram-negative (GN) and -positive (GP) bacteria, including multidrug-resistant (MDR) organisms. Our study goals were to determine the efficacy of ZTI-01 as a monotherapy or in combination with meropenem against MDR Pseudomonas aeruginosa in a preclinical model of pulmonary infection. Methods 8 week old neutropenic mice were infected with a MDR strain of P. aeruginosa via intubation-mediated intratracheal (IMIT) instillation. 3 hours after instillation, mice received treatment with ZTI-01, meropenem, or ZTI-01 plus meropenem (combination therapy) q8h for 5 days. Mice were monitored every 8 hours for 7 days for development of disease and moribund animals were humanely euthanized. Lungs and spleens were harvested at euthanasia, or at 7 days for survivors, and processed for bacterial enumeration and development of pathology. Results Mice were challenged with a lethal dose of P. aeruginosa UNC-D. Mock treated animals succumbed to infection within 36 hours post-infection. Animals that received 6 g/kg/day ZTI-01 showed an increase in the MTD (52 hours) and 25% of the cohort were protected from lethal disease. Combining ZTI-01 with meropenem resulted in a significant increase in survival (≥75% of cohorts survived infection). Combination therapy also significantly decreased bacterial numbers in the lungs and inhibited dissemination to the spleens. Furthermore, animals receiving combination therapy were protected from significant inflammation in the lungs and the development of pneumonia. Conclusion Here we report that combination therapy with ZTI-01 and meropenem provides significant improvements in all disease manifestations over treatment with

  10. Novel high dose rate lip brachytherapy technique to improve dose homogeneity and reduce toxicity by customized mold

    International Nuclear Information System (INIS)

    Feldman, Jon; Appelbaum, Limor; Sela, Mordechay; Voskoboinik, Ninel; Kadouri, Sarit; Weinberger, Jeffrey; Orion, Itzhak; Meirovitz, Amichay

    2014-01-01

    The purpose of this study is to describe a novel brachytherapy technique for lip Squamous Cell Carcinoma, utilizing a customized mold with embedded brachytherapy sleeves, which separates the lip from the mandible, and improves dose homogeneity. Seven patients with T2 lip cancer treated with a “sandwich” technique of High Dose Rate (HDR) brachytherapy to the lip, consisting of interstitial catheters and a customized mold with embedded catheters, were reviewed for dosimetry and outcome using 3D planning. Dosimetric comparison was made between the “sandwich” technique to “classic” – interstitial catheters only plan. We compared dose volume histograms for Clinical Tumor Volume (CTV), normal tissue “hot spots” and mandible dose. We are reporting according to the ICRU 58 and calculated the Conformal Index (COIN) to show the advantage of our technique. The seven patients (ages 36–81 years, male) had median follow-up of 47 months. Four patients received Brachytherapy and External Beam Radiation Therapy, 3 patients received brachytherapy alone. All achieved local control, with excellent esthetic and functional results. All patients are disease free. The Customized Mold Sandwich technique (CMS) reduced the high dose region receiving 150% (V150) by an average of 20% (range 1–47%), The low dose region (les then 90% of the prescribed dose) improved by 73% in average by using the CMS technique. The COIN value for the CMS was in average 0.92 as opposed to 0.88 for the interstitial catheter only. All differences (excluding the low dose region) were statistically significant. The CMS technique significantly reduces the high dose volume and increases treatment homogeneity. This may reduce the potential toxicity to the lip and adjacent mandible, and results in excellent tumor control, cosmetic and functionality

  11. Preliminary Toxicity Analysis of 3-Dimensional Conformal Radiation Therapy Versus Intensity Modulated Radiation Therapy on the High-Dose Arm of the Radiation Therapy Oncology Group 0126 Prostate Cancer Trial

    Energy Technology Data Exchange (ETDEWEB)

    Michalski, Jeff M., E-mail: jmichalski@radonc.wustl.edu [Department of Radiation Oncology Washington University Medical Center, St. Louis, Missouri (United States); Yan, Yan [Radiation Therapy Oncology Group Statistical Center, Philadelphia, Pennsylvania (United States); Watkins-Bruner, Deborah [Emory University School of Nursing, Atlanta, Georgia (United States); Bosch, Walter R. [Department of Radiation Oncology Washington University Medical Center, St. Louis, Missouri (United States); Winter, Kathryn [Radiation Therapy Oncology Group Statistical Center, Philadelphia, Pennsylvania (United States); Galvin, James M. [Department of Radiation Oncology Thomas Jefferson University Hospital, Philadelphia, Pennsylvania (United States); Bahary, Jean-Paul [Department of Radiation Oncology Centre Hospitalier de l' Université de Montréal-Notre Dame, Montreal, QC (Canada); Morton, Gerard C. [Department of Radiation Oncology Toronto-Sunnybrook Regional Cancer Centre, Toronto, ON (Canada); Parliament, Matthew B. [Department of Oncology Cross Cancer Institute, Edmonton, AB (Canada); Sandler, Howard M. [Department of Radiation Oncology Samuel Oschin Comprehensive Cancer Institute, Cedars-Sinai Medical Center, Los Angeles, California (United States)

    2013-12-01

    Purpose: To give a preliminary report of clinical and treatment factors associated with toxicity in men receiving high-dose radiation therapy (RT) on a phase 3 dose-escalation trial. Methods and Materials: The trial was initiated with 3-dimensional conformal RT (3D-CRT) and amended after 1 year to allow intensity modulated RT (IMRT). Patients treated with 3D-CRT received 55.8 Gy to a planning target volume that included the prostate and seminal vesicles, then 23.4 Gy to prostate only. The IMRT patients were treated to the prostate and proximal seminal vesicles to 79.2 Gy. Common Toxicity Criteria, version 2.0, and Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late morbidity scores were used for acute and late effects. Results: Of 763 patients randomized to the 79.2-Gy arm of Radiation Therapy Oncology Group 0126 protocol, 748 were eligible and evaluable: 491 and 257 were treated with 3D-CRT and IMRT, respectively. For both bladder and rectum, the volumes receiving 65, 70, and 75 Gy were significantly lower with IMRT (all P<.0001). For grade (G) 2+ acute gastrointestinal/genitourinary (GI/GU) toxicity, both univariate and multivariate analyses showed a statistically significant decrease in G2+ acute collective GI/GU toxicity for IMRT. There were no significant differences with 3D-CRT or IMRT for acute or late G2+ or 3+ GU toxicities. Univariate analysis showed a statistically significant decrease in late G2+ GI toxicity for IMRT (P=.039). On multivariate analysis, IMRT showed a 26% reduction in G2+ late GI toxicity (P=.099). Acute G2+ toxicity was associated with late G3+ toxicity (P=.005). With dose–volume histogram data in the multivariate analysis, RT modality was not significant, whereas white race (P=.001) and rectal V70 ≥15% were associated with G2+ rectal toxicity (P=.034). Conclusions: Intensity modulated RT is associated with a significant reduction in acute G2+ GI/GU toxicity. There is a trend for a

  12. Acute Complications After High-Dose Chemotherapy and Stem-Cell Rescue in Pediatric Patients With High-Risk Neuroblastoma Treated in Countries With Different Resources

    Directory of Open Access Journals (Sweden)

    Mahmoud M. Elzembely

    2018-03-01

    Full Text Available Purpose: High-dose chemotherapy with autologous stem-cell rescue (SCR is a key component of high-risk neuroblastoma (HRNB therapy. Carboplatin, etoposide, and melphalan (CEM or busulfan and melphalan (Bu/Mel are the most evaluated, effective high-dose chemotherapy for HRNB on the basis of results from major cooperative group studies. Toxicity profiles vary between these regimens, and practice variation exists regarding the preferred high-dose therapy (HDT. We sought to evaluate the safety of HDT and autologous SCR for HRNB in a resource-limited country (Egypt compared with the resource-rich United States. Patients and Methods: We performed a retrospective comparative review of single CEM-based HDT/SCR outcomes through day 100 for HRNB at the Fred Hutchinson Cancer Research Center (FH in the United States (2005 to 2015 versus Bu/Mel-based HDT at El-Sheikh Zayed Specialized Hospital (SZ in Egypt (2009 to 2015. Results: Forty-four patients at FH and 77 patients at SZ were reviewed. Pretransplant hepatic comorbidities were significantly higher at SZ (29 of 77 v nine of 44; P = .05, with 19 of 77 patients at SZ having hepatitis infection. Engraftment was delayed after SZ-Bu/Mel therapy compared with FH-CEM therapy for neutrophils (median 12 days v 10 days, respectively; P < .001 and platelets (median 20 days v 18 days, respectively; P < .001. Sinusoidal obstruction syndrome occurred later, after SZ-Bu/Mel therapy (median 19 days v 7 days; P = .033, and four of eight cases were fatal (six of eight patients had underlying hepatitis infection, whereas three of three cases after FH-CEM therapy were moderately severe. Resource utilization associated with the number of days with fever, antibiotic use, and the number of transfusions administered was significantly higher after FH-CEM therapy than after SZ-Bu/Mel therapy. Conclusion: Use of autologous stem-cell transplantation is feasible in the context of a resource-limited country.

  13. SU-E-T-577: Obliquity Factor and Surface Dose in Proton Beam Therapy

    International Nuclear Information System (INIS)

    Das, I; Andersen, A; Coutinho, L

    2015-01-01

    Purpose: The advantage of lower skin dose in proton beam may be diminished creating radiation related sequalae usually seen with photon and electron beams. This study evaluates the surface dose as a complex function of beam parameters but more importantly the effect of beam angle. Methods: Surface dose in proton beam depends on the beam energy, source to surface distance, the air gap between snout and surface, field size, material thickness in front of surface, atomic number of the medium, beam angle and type of nozzle (ie double scattering, (DS), uniform scanning (US) or pencil beam scanning (PBS). Obliquity factor (OF) is defined as ratio of surface dose in 0° to beam angle Θ. Measurements were made in water phantom at various beam angles using very small microdiamond that has shown favorable beam characteristics for high, medium and low proton energy. Depth dose measurements were performed in the central axis of the beam in each respective gantry angle. Results: It is observed that surface dose is energy dependent but more predominantly on the SOBP. It is found that as SSD increases, surface dose decreases. In general, SSD, and air gap has limited impact in clinical proton range. High energy has higher surface dose and so the beam angle. The OF rises with beam angle. Compared to OF of 1.0 at 0° beam angle, the value is 1.5, 1.6, 1,7 for small, medium and large range respectively for 60 degree angle. Conclusion: It is advised that just like range and SOBP, surface dose should be clearly understood and a method to reduce the surface dose should be employed. Obliquity factor is a critical parameter that should be accounted in proton beam therapy and a perpendicular beam should be used to reduce surface dose

  14. Combination of nitric oxide stimulation with high-dose 18F-FDG promotes apoptosis and enhances radiation therapy of endothelial cells

    International Nuclear Information System (INIS)

    Paik, Jin-Young; Park, Jin-Won; Jung, Kyung-Ho; Lee, Eun Jeong; Lee, Kyung-Han

    2012-01-01

    Introduction: High-dose 18 F-FDG can provide targeted nuclear therapy of cancer. Endothelial cell injury is a key determinant of tumor response to radiotherapy. Here, we tested the hypothesis that activation of endothelial cell glycolytic metabolism with nitric oxide can enhance the therapeutic effect of high-dose 18 F-FDG. Methods: Calf pulmonary artery endothelial (CPAE) cells were treated with graded doses of 18 F-FDG. Glycolysis was stimulated by 24 h of exposure to the nitric oxide donor, sodium nitroprusside (SNP). Cell viability was assessed by MTT and clonogenic assays. Apoptosis was evaluated by ELISA of cytosolic DNA fragments and Western blots of cleaved caspase-3. Results: SNP stimulation (0.1 and 1 mM) augmented CPAE cell 18 F-FDG uptake to 2.6- and 4.6-fold of controls without adverse effects. Treatment with 333 μCi/ml 18 F-FDG alone reduced viable cell number to 35.4% of controls by Day 3. Combining 0.1 mM SNP stimulation significantly enhanced the killing effect, reducing cell numbers to 19.2% and 39.2% of controls by 333 and 167 μCi/ml of 18 F-FDG, respectively. 18 F-FDG also suppressed clonogenic survival to 80.8% and 43.2% of controls by 83 and 167 μCi/ml, which was again intensified by SNP to 59.7% and 21.1% of controls. The cytotoxic effect of 18 F-FDG was attributed to induction of apoptosis as shown by increased cytosolic fragmented DNA and cleaved caspase-3 levels (26.4% and 30.7% increases by 167 μCi/ml). Combining SNP stimulation significantly increased both of these levels to 1.8-fold of control cells. Conclusion: High-dose 18 F-FDG combined with nitric oxide-stimulated glycolysis is an effective method to inhibit endothelial cell survival and promote apoptosis. These results suggest a potential role of this strategy for targeted radiotherapy of angiogenic vasculature.

  15. Comparison of effectiveness and safety of imipenem/clavulanate- versus meropenem/clavulanate-containing regimens in the treatment of MDR- and XDR-TB

    NARCIS (Netherlands)

    Tiberi, Simon; Sotgiu, Giovanni; D'Ambrosio, Lia; Centis, Rosella; Arbex, Marcos Abdo; Arrascue, Edith Alarcon; Alffenaar, Jan Willem; Caminero, Jose A.; Gaga, Mina; Gualano, Gina; Skrahina, Alena; Solovic, Ivan; Sulis, Giorgia; Tadolini, Marina; Alarcon Guizado, Valentina; De Lorenzo, Saverio; Roby Arias, Aurora Jazmin; Scardigli, Anna; Akkerman, Onno W.; Aleksa, Alena; Artsukevich, Janina; Auchynka, Vera; Bonini, Eduardo Henrique; Chong Marin, Felix Antonio; Collahuazo Lopez, Lorena; de Vries, Gerard; Dore, Simone; Kunst, Heinke; Matteelli, Alberto; Moschos, Charalampos; Palmieri, Fabrizio; Papavasileiou, Apostolos; Payen, Marie-Christine; Piana, Andrea; Spanevello, Antonio; Vargas Vasquez, Dante; Viggiani, Pietro; White, Veronica; Zumla, Alimuddin; Migliori, Giovanni Battista

    No large study to date has ever evaluated the effectiveness, safety and tolerability of imipenem/clavulanate versus meropenem/clavulanate to treat multidrug-and extensively drug-resistant tuberculosis (MDR- and XDR-TB). The aim of this observational study was to compare the therapeutic contribution

  16. Intermediate doses of rituximab used as adjuvant therapy in refractory pemphigus

    Directory of Open Access Journals (Sweden)

    Pradnya J Londhe

    2014-01-01

    Full Text Available Background: Rituximab, a monoclonal anti-CD20 antibody, has been used with encouraging results in pemphigus. We describe herein refractory cases of pemphigus vulgaris (n = 23 and pemphigus foliaceus (n = 1 treated with rituximab in addition to steroids and immunosuppressants. Aims: To assess the response to treatment, the duration of clinical remission, serology of the response and adverse effects of rituximab in pemphigus patients. Methods: We recorded observations of 24 patients with pemphigus having either refractory disease in spite of high dose of steroids and immunosuppressants, corticosteroid-dependent disease, strong contraindications to corticosteroids, or severe disease. The patients were treated with infusions of one injection per week for three consecutive weeks of 375 mg of rituximab per m 2 of body-surface area. One similar infusion was repeated after 3 months of 3 rd dose. We observed the clinical outcome after 6 months of 3 rd dose of rituximab and looked for complete healing of cutaneous and mucosal lesions (complete remission. Observations: After follow-up of 7-24 months, five patients showed only partial improvement while 19 of 24 patients had a complete remission 3 months after rituximab. Of these 19 patients, 12 patients achieved complete remission and are off all systemic therapy, and the rest are continuing with no or low dose of steroids with immunosuppressants. Two patients relapsed after initial improvement; one was given moderate dose of oral steroids and immunosuppressant and the other was given repeat single dose of rituximab to control relapse. Conclusion: Rituximab is able to induce a prolonged clinical remission in pemphigus after a single course of four infusions. The high cost and limited knowledge of long term adverse effects are limitations to the use of this biologic agent.

  17. Clinical review: Optimal dose of continuous renal replacement therapy in acute kidney injury.

    Science.gov (United States)

    Prowle, John R; Schneider, Antoine; Bellomo, Rinaldo

    2011-01-01

    Continuous renal replacement therapy (CRRT) is the preferred treatment for acute kidney injury in intensive care units (ICUs) throughout much of the world. Despite the widespread use of CRRT, controversy and center-specific practice variation in the clinical application of CRRT continue. In particular, whereas two single-center studies have suggested survival benefit from delivery of higher-intensity CRRT to patients with acute kidney injury in the ICU, other studies have been inconsistent in their results. Now, however, two large multi-center randomized controlled trials - the Veterans Affairs/National Institutes of Health Acute Renal Failure Trial Network (ATN) study and the Randomized Evaluation of Normal versus Augmented Level (RENAL) Replacement Therapy Study - have provided level 1 evidence that effluent flow rates above 25 mL/kg per hour do not improve outcomes in patients in the ICU. In this review, we discuss the concept of dose of CRRT, its relationship with clinical outcomes, and what target optimal dose of CRRT should be pursued in light of the high-quality evidence now available.

  18. SU-F-T-137: Out-Of-Beam Dose for a Compact Double-Scattering Proton Beam Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M; Ahmad, S; Jin, H [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: The out-of-beam dose is important for understanding the peripheral dose in radiation therapy. In proton radiotherapy, the study of out-of-beam dose is scarce and the treatment planning system (TPS) based on pencil beam algorithm cannot accurately predict the out-of-beam dose. This study investigates the out-of-beam dose for the single-room Mevion S250 double scattering proton therapy system using experimentally measured and treatment planning software generated data. The results are compared with those reported for conventional photon beam therapy. However, this study does not incorporate the neutron contribution in the scattered dose. Methods: A total of seven proton treatment plans were generated using Varian Eclipse TPS for three different sites (brain, lung, and pelvis) in an anthropomorphic phantom. Three field sizes of 5×5, 10×10, and 20×20 cm{sup 2} (lung only) with typical clinical range (13.3–22.8 g/cm{sup 2}) and modulation widths (5.3–14.0 g/cm{sup 2}) were used. A single beam was employed in each treatment plan to deliver a dose of 181.8 cGy (200.0 cGy (RBE)) to the selected target. The out-of-beam dose was measured at 2.0, 5.0, 10.0, and 15.0 cm from the beam edge in the phantom using a thimble chamber (PTW TN31010). Results: The out-of-beam dose generally increased with field size, range, and volume irradiated. For all the plans, the scattered dose sharply fell off with distance. At 2.0 cm, the out-of-beam dose ranged from 0.35% to 2.16% of the delivered dose; however, the dose was clinically negligible (<0.3%) at a distance of 5.0 cm and greater. In photon therapy, the slightly greater out-of-beam dose was reported (TG36; 4%, 2%, and 1% for 2.0, 5.0, and 10.0 cm, respectively, using 6 MV beam). Conclusion: The measured out-of-beam dose in proton therapy excluding neutron contribution was observed higher than the TPS calculated dose and comparable to that of photon beam therapy.

  19. Isoeffective dose: a concept for biological weighting of absorbed dose in proton and heavier-ion therapies

    CERN Document Server

    Wambersie, A; Menzel, H G; Gahbauer, R; DeLuca, P M; Hendry, J H; Jones, D T L

    2011-01-01

    When reporting radiation therapy procedures, International Commission on Radiation Units and Measurements (ICRU) recommends specifying absorbed dose at/in all clinically relevant points and/or volumes. In addition, treatment conditions should be reported as completely as possible in order to allow full understanding and interpretation of the treatment prescription. However, the clinical outcome does not only depend on absorbed dose but also on a number of other factors such as dose per fraction, overall treatment time and radiation quality radiation biology effectiveness (RBE). Therefore, weighting factors have to be applied when different types of treatments are to be compared or to be combined. This had led to the concept of `isoeffective absorbed dose', introduced by ICRU and International Atomic Energy Agency (IAEA). The isoeffective dose D(IsoE) is the dose of a treatment carried out under reference conditions producing the same clinical effects on the target volume as those of the actual treatment. It i...

  20. Radiation tolerance of the cervical spinal cord: incidence and dose-volume relationship of symptomatic and asymptomatic late effects following high dose irradiation of paraspinal tumors

    International Nuclear Information System (INIS)

    Liu, Mitchell C.C.; Munzenrider, John E.; Finkelstein, Dianne; Liebsch, Norbert; Adams, Judy; Hug, Eugen B.

    1997-01-01

    Purpose: Low grade chordomas and chondrosarcomas require high radiation doses for effective, lasting tumor control. Fractionated, 3-D planned, conformal proton radiation therapy has been used for lesions along the base of skull and spine to deliver high target doses, while respecting constraints of critical, normal tissues. In this study, we sought to determine the incidence of myelopathy after high dose radiotherapy to the cervical spine and investigated the influence of various treatment parameters, including dose-volume relationship. Methods and Materials: Between December 1980 and March 1996, 78 patients were treated at the Massachusetts General Hospital and Harvard Cyclotron Laboratory for primary or recurrent chordomas and chondrosarcomas of the cervical spine using combined proton and photon radiation therapy. In general, the tumor dose given was between 64.5 to 79.2 CGE (Cobalt Gray Equivalent). The guidelines for maximum permissible doses to spinal cord were: ≤ 64 CGE to the spinal cord surface and ≤ 53 CGE to the spinal cord center. Dose volume histograms of the spinal cord were analyzed to investigate a possible dose and volume relationship. Results: With a mean follow-up period of 46.6 months (range: 3 - 157 months), 4 of 78 patients (5.1%) developed high-grade (RTOG Grade 3 and 4) late toxicity: 3 patients (3.8%) experienced sensory deficits without motor deficits, none had any limitations of daily activities. One patient (1.2%) developed motor deficit with loss of motor function of one upper extremity. The only patient, who developed permanent motor damage had received additional prior radiation treatment and therefore received a cumulative spinal cord dose higher than the treatment guidelines. No patient treated within the guidelines experienced any motor impairment. Six patients (7.7%) experienced transient Lhermitt's syndrome and 1 patient (1.2%) developed asymptomatic radiographic MR findings only. Time to onset of symptoms of radiographic

  1. Prospective study in the management of high-dose radioactive iodine therapy induced gastritis

    International Nuclear Information System (INIS)

    Carbonell, C.; Ogbac, R.V.

    2007-01-01

    Full text: Gastritis is simply defined as inflammation of the gastric mucosa. In post-RAI patients, this is one of the most common complications that are encountered. Some patients may even require repetitive administration of high doses of radioactive iodine (I-131). Small doses of radiation (up to 1500 R) cause reversible mucosal damage, whereas higher radiation doses cause irreversible damage with atrophy and ischemic-related ulceration. Reversible changes consist of degenerative changes in epithelial cells and nonspecific chronic inflammatory infiltrate in the lamina propria. Higher amounts of radiation cause permanent mucosal damage, with atrophy of fundic glands, mucosal erosions, and capillary hemorrhage. Associated submucosal endarteritis results in mucosal ischemia and secondary ulcer development. Recurrent gastritis, if left untreated, may be a predisposing factor for gastric malignancy. Methods:A total of thirty post-RAI subjects were evaluated for signs and symptoms of gastritis and were divided into 3 groups which were given drugs for gastritis (H2-receptor antagonist, proton pump inhibitor, and sucralfate). Survey forms were distributed to evaluate the presence of nausea, vomiting, epigastric pain (graded according to severity of pain), and gastrointestinal bleeding. Results were tallied accordingly. Results and Discussion: In a total of 3 subjects who were given sucralfate, all of them did not experience any nausea and vomiting. One subject experienced mild epigastric discomfort and another subject was able to experience a non-specific symptom of abdominal bloatedness. (Note: Subjects are still for completion) In theory, radiation irritates the mucosa causing inflammation and mucosal damage which is further irritated by gastric acid secretion. The administration of H2-receptor blockers and proton pump inhibitors only inhibit gastric acid secretion while existing inflammation of mucosa due to high doses of radiation is left untreated. However

  2. The results of the radioiodine-therapy of benign thyroid diseases respecting the applied radiation dose

    International Nuclear Information System (INIS)

    Maier, C.

    1994-09-01

    452 patients with benign thyroid diseases had been explored after 6 weeks, 6 months, 1 year, 5 years and 10 years after undergone radioiodine treatment retrospectively with regard to the applied radiation dose. A relevant relation between the radiation dose and the rate of hypothyroidism could only be proved as a tendency. Treating hyperthyroidism with radioiodine, the rates of hypothyroidism after therapy were not caused by significantly higher radiation doses. Therefore suggestions to change the used radiation-doses basically cannot be made. The applied doses of radiation are sufficient to achieve a rather satisfactory effect in healing hyperthyroidism. Cases of malignancy after radioiodine therapy could not be found in this population. The effective half-life determination before therapy can be neglected, because there was found a significant difference between the pre-therapeutically estimated half-life and the post-therapeutically measured effective half-life of radioiodine. Instead, fixed values of effective half-life should be used for each group of benign thyroid diseases. The radiation therapy still seems to be an efficient treatment to cure benign thyroid diseases with rare side effects. It also can be applied to patients below the age of 40. Generally it is an alternative to drug-therapy or surgery, always considering the individual relation between gain and risk. In this respect good results can be obtained and a relapse of hyperthyroidism is hardly to expect. (author)

  3. Actual survey of dose evaluation method for standardization of radiation therapy techniques. With special reference to display method of radiation doses

    International Nuclear Information System (INIS)

    Kumagai, Kozo; Yoshiura, Takao; Izumi, Takashi; Araki, Fujio; Takada, Takuo; Jingu, Kenichi.

    1994-01-01

    This report presents the results of questionnaire survey for actual conditions of radiation therapy, which was conducted with the aim of establishing the standardization of radiation therapy techniques. Questionnaires were sent to 100 facilities in Japan, and 86 of these answered, consisting of 62 university hospitals, 2 national hospitals, 14 cancer centers, 4 prefectural or municipal hospitals, and 4 other hospitals. In addition to electron beam therapy, the following typical diseases for radiation therapy were selected as standard irradiation models: cancers of the larynx, esophagus, breast, and uterine cervix, and malignant lymphomas. According to these models, questionnaire results are analyzed in terms of the following four items: (1) irradiation procedures, (2) energy used for radiotherapy, (3) the depth for calculating target absorption doses, and (4) points for displaying target absorption doses. (N.K.)

  4. Prophylactic CNS therapy in childhood leukemia. Randomized controlled study of high-dose intravenous methotrexate and cranial irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Takashi; Hiyoshi, Yasuhiko [Kurume Univ., Fukuoka (Japan). School of Medicine; Fujimoto, Takeo

    1982-12-01

    This study was designed to evaluate the efficacy of CNS-prophylaxis with high-dose methotrexate (MTX). Seventy children with previously untreated acute lymphoblastic leukemia (ALL) entered to this study between July 1978 and December 1980. According to initial white blood count (WBC), they were stratified to induce remission with; vincristine and prednine in low initial WBC ( lt 25,000/mm/sup 3/) group and these two agents plus adriamycin in high initial WBC ( gt 25,000/mm/sup 3/) group. After inducing remission, 62 children who achieved CR, received different CNS-prophlaxis; using a regimen of three doses of weekly high-dose MTX (1,000 mg/m/sup 2/) 6-hour infusion, which was repeated every 12 weeks-Group A (n = 14); high-dose MTX followed by 2400 rad cranial irradiation plus three doses of i.t. MT X-Group B (n = 15), 2400 rad cranial irradiation plus three doses of i.t. MTX-Group C (n = 16), and in 17 patients with high initial WBC, same as in Group A-Group D (n = 17). During an intravenous 6-h infusion of MTX at a dose of 1,000 mg/m/sup 2/, the CSF concentration of MTX rose to 2.3 +- 2.4 x 10/sup -6/M after initiation of infusion and remained in 10/sup -7/ M level for 48 hours. CNS-leukemia terminated complete remission in one of 14 children in Group A, two of 15 in Group B, two of 16 in Group C and two of 17 in Group D. The cumulative incidence of CNS-leukemia at 20 months calculated by the technique of Kaplan and Meier was 0% in Group A, 18.1% in Group B, 7.1% in Group C and 50.8% in Group D. There was no statistical difference among Groups A, B and C. These data suggested that CNS-prophylaxis with high-dose intravenous MTX was effective as well as 2400 rad cranial irradiation plus three doses of i.t. MTX in childhood ALL with low initial WBC.

  5. Clinical trial of combination therapy using systemic interleukin-2 infusion and low-dose tumor irradiation for advanced hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Tsuchida, Tetsuo; Hiragushi, Junji; Asano, Yoshihide

    1995-01-01

    Although recent progress in surgical techniques and interventional radiology enables patients with hepatocellular carcinoma (HCC) to survive longer, there are still many who cannot receive them due to disease progression. We are currently investigating the therapeutic efficacy of the combination of systemic recombinant interleukin-2 (IL-2) administration and local tumor irradiation for HCC patients in the advanced stage. First, the results of the basic experiment to analyze the optimal dose and timing of IL-2 infusion were demonstrated. Intensive administration of high-dose IL-2 caused acute death, whereas intermittent low-dose IL-2 administration resulted in complete tumor regression followed by the acquisition of tumor-specific immunity. Our data suggested that the tumor-bearing state increased the responsiveness to IL-2 treatment, and that an excessively high-dose regimen is not prerequisite for the optimal IL-2 treatment. With regard to the effectiveness of radiotherapy for HCC, human hepatoma cells exhibited apoptotic death when hepatoma cells were cocultured with LAK cells, or were irradiated in vitro with relatively low-dose irradiation. These results suggested the possible synergistic effect of killer cells and low-dose irradiation. Finally, we presented six eligible cases of advanced HCC treated by combination therapy of IL-2 infusion and local low-dose tumor irradiation. Direct anti-tumor effects were one CR, one MR, two NC, and two PD. One CR case and a NC case have survived now for longer than 40 months. In all cases, NK cell activity increased prominently, and side effects wee mild flu-like symptoms except macroscopic hematuria and moderate VLS-like symptoms in two cases in which therapy was continued for longer than 2 years. Hepatic reserve function like prothrombin time or hepaplastic time improved. The apparent clinical effectiveness of the combination therapy presented here might give promising hints for a new therapeutic strategy for HCC. (author)

  6. Antibiotic susceptibility of Gram-negatives isolated from bacteremia in children with cancer. Implications for empirical therapy of febrile neutropenia.

    Science.gov (United States)

    Castagnola, Elio; Caviglia, Ilaria; Pescetto, Luisa; Bagnasco, Francesca; Haupt, Riccardo; Bandettini, Roberto

    2015-01-01

    Monotherapy is recommended as the first choice for initial empirical therapy of febrile neutropenia, but local epidemiological and antibiotic susceptibility data are now considered pivotal to design a correct management strategy. To evaluate the proportion of Gram-negative rods isolated in bloodstream infections in children with cancer resistant to antibiotics recommended for this indication. The in vitro susceptibility to ceftazidime, piperacillin-tazobactam, meropenem and amikacin of Gram-negatives isolated in bacteremic episodes in children with cancer followed at the Istituto "Giannina Gaslini", Genoa, Italy in the period of 2001-2013 was retrospectively analyzed using the definitions recommended by EUCAST in 2014. Data were analyzed for any single drug and to the combination of amikacin with each β-lactam. The combination was considered effective in absence of concomitant resistance to both drugs, and not evaluated by means of in vitro analysis of antibiotic combinations (e.g., checkerboard). A total of 263 strains were evaluated: 27% were resistant to piperacillin-tazobactam, 23% to ceftazidime, 12% to meropenem and 13% to amikacin. Concomitant resistance to β-lactam and amikacin was detected in 6% of strains for piperacillin-tazobactam, 5% for ceftazidime and 5% for meropenem. During the study period there was a nonsignificant increase in the proportions of strains resistant to β-lactams indicated for monotherapy, and also increase in the resistance to combined therapies. in an era of increasing resistance to antibiotics guideline-recommended monotherapy could be not appropriate for initial empirical therapy of febrile neutropenia. Strict local survey on etiology and antibiotic susceptibility is mandatory for a correct management of this complication in cancer patients.

  7. Monte Carlo characterisation of the Dose Magnifying Glass for proton therapy quality assurance

    International Nuclear Information System (INIS)

    Merchant, A H; Guatelli, S; Petesecca, M; Jackson, M; Rozenfeld, A B

    2017-01-01

    A Geant4 Monte Carlo simulation study was carried out to characterise a novel silicon strip detector, the Dose Magnifying Glass (DMG), for use in proton therapy Quality Assurance. We investigated the possibility to use DMG to determine the energy of the incident proton beam. The advantages of DMG are quick response, easy operation and high spatial resolution. In this work we theoretically proved that DMG can be used for QA in the determination of the energy of the incident proton beam, for ocular and prostate cancer therapy. The study was performed by means of Monte Carlo simulations Experimental measurements are currently on their way to confirm the results of this simulation study. (paper)

  8. Monte Carlo characterisation of the Dose Magnifying Glass for proton therapy quality assurance

    Science.gov (United States)

    Merchant, A. H.; Guatelli, S.; Petesecca, M.; Jackson, M.; Rozenfeld, A. B.

    2017-01-01

    A Geant4 Monte Carlo simulation study was carried out to characterise a novel silicon strip detector, the Dose Magnifying Glass (DMG), for use in proton therapy Quality Assurance. We investigated the possibility to use DMG to determine the energy of the incident proton beam. The advantages of DMG are quick response, easy operation and high spatial resolution. In this work we theoretically proved that DMG can be used for QA in the determination of the energy of the incident proton beam, for ocular and prostate cancer therapy. The study was performed by means of Monte Carlo simulations Experimental measurements are currently on their way to confirm the results of this simulation study.

  9. High phenobarbital clearance during continuous renal replacement therapy: a case report and pharmacokinetic analysis.

    Science.gov (United States)

    Rosenborg, Staffan; Saraste, Lars; Wide, Katarina

    2014-08-01

    Phenobarbital is an old antiepileptic drug used in severe epilepsy. Despite this, little is written about the need for dose adjustments in renal replacement therapy. Most sources recommend a moderately increased dose guided by therapeutic drug monitoring.A 14 year old boy with nonketotic hyperglycinemia, a rare inborn error of metabolism, characterized by high levels of glycine, epilepsy, spasticity, and cognitive impairment, was admitted to the emergency department with respiratory failure after a few days of fever and cough. The boy was unconscious at admittance and had acute renal and hepatic failure.Due to the acute respiratory infection, hypoxic hepatic and renal failure occurred and the patient had a status epilepticus.The patient was intubated and mechanically ventilated. Continuous renal replacement therapy was initiated. Despite increased phenobarbital doses, therapeutic levels were not reached until the dose was increased to 500 mg twice daily. Therapeutic drug monitoring was performed in plasma and dialysate. Calculations revealed that phenobarbital was almost freely dialyzed.Correct dosing of drugs in patients on renal replacement therapy may need a multidisciplinary approach and guidance by therapeutic drug monitoring.

  10. Nominal effective radiation doses delivered during clinical trials of boron neutron capture therapy

    International Nuclear Information System (INIS)

    Capala, J.; Diaz, A.Z.; Chanana, A.D.

    1997-01-01

    Boron neutron capture therapy (BNCT) is a binary system that, in theory, should selectively deliver lethal, high linear energy transfer (LET) radiation to tumor cells dispersed within normal tissues. It is based on the nuclear reaction 10-B(n, α)7-Li, which occurs when the stable nucleus of boron-10 captures a thermal neutron. Due to the relatively high cross-section of the 10-B nucleus for thermal neutron capture and short ranges of the products of this reaction, tumor cells in the volume exposed to thermal neutrons and containing sufficiently high concentration of 10-B would receive a much higher radiation dose than the normal cells contained within the exposed volume. Nevertheless, radiation dose deposited in normal tissue by gamma and fast neutron contamination of the neutron beam, as well as neutron capture in nitrogen, 14-N(n,p)14-C, hydrogen, 1-H(n,γ)2-H, and in boron present in blood and normal cells, limits the dose that can be delivered to tumor cells. It is, therefore, imperative for the success of the BNCT the dosed delivered to normal tissues be accurately determined in order to optimize the irradiation geometry and to limit the volume of normal tissue exposed to thermal neutrons. These are the major objectives of BNCT treatment planning

  11. Exposure of the Heart in Breast Cancer Radiation Therapy: A Systematic Review of Heart Doses Published During 2003 to 2013

    International Nuclear Information System (INIS)

    Taylor, Carolyn W.; Wang, Zhe; Macaulay, Elizabeth; Jagsi, Reshma; Duane, Frances; Darby, Sarah C.

    2015-01-01

    Purpose: Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Methods and Materials: Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this “mean heart dose.” Results: In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28 countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Conclusions: Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose.

  12. Intensity Modulated Radiation Therapy With Dose Painting to Treat Rhabdomyosarcoma

    International Nuclear Information System (INIS)

    Yang, Joanna C.; Dharmarajan, Kavita V.; Wexler, Leonard H.; La Quaglia, Michael P.; Happersett, Laura; Wolden, Suzanne L.

    2012-01-01

    Purpose: To examine local control and patterns of failure in rhabdomyosarcoma patients treated with intensity modulated radiation therapy (RT) with dose painting (DP-IMRT). Patients and Methods: A total of 41 patients underwent DP-IMRT with chemotherapy for definitive treatment. Nineteen also underwent surgery with or without intraoperative RT. Fifty-six percent had alveolar histologic features. The median interval from beginning chemotherapy to RT was 17 weeks (range, 4-25). Very young children who underwent second-look procedures with or without intraoperative RT received reduced doses of 24-36 Gy in 1.4-1.8-Gy fractions. Young adults received 50.4 Gy to the primary tumor and lower doses of 36 Gy in 1.8-Gy fractions to at-risk lymph node chains. Results: With 22 months of median follow-up, the actuarial local control rate was 90%. Patients aged ≤7 years who received reduced overall and fractional doses had 100% local control, and young adults had 79% (P=.07) local control. Three local failures were identified in young adults whose primary target volumes had received 50.4 Gy in 1.8-Gy fractions. Conclusions: DP-IMRT with lower fractional and cumulative doses is feasible for very young children after second-look procedures with or without intraoperative RT. DP-IMRT is also feasible in adolescents and young adults with aggressive disease who would benefit from prophylactic RT to high-risk lymph node chains, although dose escalation might be warranted for improved local control. With limited follow-up, it appears that DP-IMRT produces local control rates comparable to those of sequential IMRT in patients with rhabdomyosarcoma.

  13. Comparison of the Influence on the Liver Function Between Thyroid Hormone Withdrawal and rh-TSH Before High-Dose Radioiodine Therapy in Patients with Well-Differentiated Thyroid Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Han, Yeon-Hee; Lim, Seok Tae; Yun, Kuk-No; Yim, Sung Kyun; Kim, Dong Wook; Jeong, Hwan-Jeong; Sohn, Myung-Hee [Chonbuk National Univ. Medical School and Hospital, Jeonju (Korea, Republic of)

    2012-06-15

    An elevated thyroid stimulating hormone level (TSH) is essential to stimulate the uptake of radioiodine into thyroid remnants and metastases and metastases of thyroid cancer when a patient under-goes high-dose radioiodine therapy. Nowadays, recombinant human thyroid stimulating hormone (rh-TSH) is increasingly used instead of the classic method of thyroid hormone withdrawal (THW). However, beyond the therapeutic effects, clinical differences between the two methods have not yet been clearly demonstrated. The aim of this work was to investigate the effects of the two methods, especially on liver function. We identified 143 evaluable patients who were further divided into two groups: THW and rh-TSH. We first reviewed the aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels, which were measured during the admission period for total thyroidectomy. We called these liver enzyme levels 'base AST' and 'base ALT.' We also assessed other chemistry profiles, including AST, ALT, total cholesterol, LDL cholesterol, alkaline phosphatase (ALP), total bilirubin (TB), and triglyceride (TG), which were measured on admission day for high-dose radioiodine therapy. We called these liver enzyme levels 'follow-up AST'and 'follow-up ALT.' We compared the changes in base and follow-up liver enzyme levels and the other chemistry profiles between the two groups. The base AST and base ALT levels of the two groups were within normal range, and there was no significant difference between the two groups. In contrast to these base liver enzyme levels, follow-up AST and ALT levels than did the rh-TSH group. Patients in the THW group. Patients in the THW group also had higher levels of total cholesterol and LDL cholesterol than did the patients in the rh-TSH group. However there were no statistically significant differences in ALP, total bilirubin, and triglyceride levels between the two groups. In this retrospective analysis of liver

  14. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  15. Radioiodine therapy induces dose-dependent in-vivo oxidation injury

    International Nuclear Information System (INIS)

    Sinzinger, H.; Resch, U.; Tatzber, F.; Weiss, K.

    2002-01-01

    Until now, radiation hazards as a consequence of radioiodine therapy are not examined in detail. Oxidation of lipoproteins may favour vasculopathy. We studied the influence of a single radioiodine therapy with 5 (n=8; 46-71a), 10 (n=6; 54-75a), 20 (n=11; 45-73a), 80 (n=6; 37-75a) or 200 (n=6; 43-67a) mCi on in-vivo oxidation injury in blood (plasma [P], serum [Se]), urine (U) and saliva (Sa) in patients suffering from hyperthyroidism opr thyroid cancer, respectively. The isoprostane 8-epi-prostaglandin (PG) F 2α as a marker of in-vivo oxidation injury (Sa, Se, P, U), oxidation of lipoproteins (LDL, HDL), thromboxane B2 (Sa, Se, P, U), PGE 2 , PGF 2α and circulating endothelial cells (CEC) were examined before therapy, daily for 7 days and weekly thereafter for 6 weeks. Blood was also analyzed for thiobarbituric acid reactive substances (TBARS), relative electrophoretic mobility (REM), baseline dienes (BD), endogenous peroxides (POX) and formation of conjugated dienes in copper-mediated oxidation (CD) expressed in lag-time and rate of propagation. There is a dose-dependent increase in 8-epi-PGF 2α being most pronounced in saliva (p 2 and HDL 3 subfractions 24 h after application, but 48 h and 72 h after application there was a significant increase in TBARS, REM, BD, POX and rate of propagation and a decrease in lag-time in HDL-subfractions independently from applied dose. Also HDL 2 showed more TBARS, REM, BD, POX and shorter lag-time than HDL 3 48 h after application, but this effect was reversed 72 h after application. HDL is the lipoprotein most prone to oxidation by radioiodine treatment. Apparently, when LDL becomes oxidized, it shifts metabolically its oxidation products to HDL. These findings show a significant temporary and dose-dependent endothelial desquamation, oxidation of lipoproteins and long-lasting in-vivo oxidation injury (saliva > urine > blood) as side effect of radioiodine therapy, altogether being potentially proatherogenic

  16. Adoptive cell therapy with autologous tumor infiltrating lymphocytes and low-dose Interleukin-2 in metastatic melanoma patients

    Directory of Open Access Journals (Sweden)

    Ellebaek Eva

    2012-08-01

    Full Text Available Abstract Background Adoptive cell therapy may be based on isolation of tumor-specific T cells, e.g. autologous tumor infiltrating lymphocytes (TIL, in vitro activation and expansion and the reinfusion of these cells into patients upon chemotherapy induced lymphodepletion. Together with high-dose interleukin (IL-2 this treatment has been given to patients with advanced malignant melanoma and impressive response rates but also significant IL-2 associated toxicity have been observed. Here we present data from a feasibility study at a Danish Translational Research Center using TIL adoptive transfer in combination with low-dose subcutaneous IL-2 injections. Methods This is a pilot trial (ClinicalTrials.gov identifier: NCT00937625 including patients with metastatic melanoma, PS ≤1, age Results Low-dose IL-2 considerably decreased the treatment related toxicity with no grade 3–4 IL-2 related adverse events. Objective clinical responses were seen in 2 of 6 treated patients with ongoing complete responses (30+ and 10+ months, 2 patients had stable disease (4 and 5 months and 2 patients progressed shortly after treatment. Tumor-reactivity of the infused cells and peripheral lymphocytes before and after therapy were analyzed. Absolute number of tumor specific T cells in the infusion product tended to correlate with clinical response and also, an induction of peripheral tumor reactive T cells was observed for 1 patient in complete remission. Conclusion Complete and durable responses were induced after treatment with adoptive cell therapy in combination with low-dose IL-2 which significantly decreased toxicity of this therapy.

  17. Dose concepts and dosimetry for radioiodine therapy of benign thyroid diseases

    International Nuclear Information System (INIS)

    Bockisch, A.; Brandt-Mainz, K.; Goerges, R.

    1997-01-01

    Dose planning prior to radioiodine therapy of benign thyroidal disease is usually based on macrodosimetry. The paper shows that this assumption is acceptable. The common concepts for dose planning are given. The following target doses are nowadays widely accepted: 150 Gy for euthyroid goiter, 400 Gy for toxic adenoma, 150 Gy for disserminated autonomy, 200 Gy for hyperthyroid Grave's disease if posttherapeutic euthyroidism is intended, and 250 (to 300) Gy if the risk of recurrency is to be minimized ('ablative' concept). Finally, a surveyfis given concerning the precision in which the parameters relevant for the dose calcultion can be determined. For realistic favourable conditions, the dose can be determined with an accuracy of better than ±25%. (orig.) [de

  18. Phantom experiment of depth-dose distributions for gadolinium neutron capture therapy

    International Nuclear Information System (INIS)

    Matsumoto, T.; Kato, K.; Sakuma, Y.; Tsuruno, A.; Matsubayashi, M.

    1993-01-01

    Depth-dose distributions in a tumor simulated phantom were measured for thermal neutron flux, capture gamma-ray and internal conversion electron dose rates for gadolinium neutron capture therapy. The results show that (i) a significant dose enhancement can be achieved in the tumor by capture gamma-rays and internal conversion electrons but the dose is mainly due to capture gamma-rays from the Gd(n, γ) reactions, therefore, is not selective at the cellular level, (ii) the dose distribution was a function of strongly interrelated parameters such as gadolinium concentrations, tumor site and neutron beam size (collimator aperture size), and (iii) the Gd-NCT by thermal neutrons appears to be a potential for treatment of superficial tumor. (author)

  19. Radiation Dose to the Esophagus From Breast Cancer Radiation Therapy, 1943-1996: An International Population-Based Study of 414 Patients

    International Nuclear Information System (INIS)

    Lamart, Stephanie; Stovall, Marilyn; Simon, Steven L.; Smith, Susan A.; Weathers, Rita E.; Howell, Rebecca M.; Curtis, Rochelle E.; Aleman, Berthe M.P.; Travis, Lois; Kwon, Deukwoo; Morton, Lindsay M.

    2013-01-01

    Purpose: To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. Methods and Materials: We abstracted the radiation therapy treatment parameters from each patient’s radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were 60 Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Results: Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Conclusions: Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower doses

  20. Radiation dose to the esophagus from breast cancer radiation therapy, 1943-1996: an international population-based study of 414 patients.

    Science.gov (United States)

    Lamart, Stephanie; Stovall, Marilyn; Simon, Steven L; Smith, Susan A; Weathers, Rita E; Howell, Rebecca M; Curtis, Rochelle E; Aleman, Berthe M P; Travis, Lois; Kwon, Deukwoo; Morton, Lindsay M

    2013-07-15

    To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. We abstracted the radiation therapy treatment parameters from each patient's radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were (60)Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower doses. Published by Elsevier Inc.

  1. Radiation Dose to the Esophagus From Breast Cancer Radiation Therapy, 1943-1996: An International Population-Based Study of 414 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Lamart, Stephanie, E-mail: stephanie.lamart@nih.gov [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Stovall, Marilyn [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Simon, Steven L. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Smith, Susan A.; Weathers, Rita E.; Howell, Rebecca M. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Curtis, Rochelle E. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States); Aleman, Berthe M.P. [Department of Radiotherapy, The Netherlands Cancer Institute, Amsterdam (Netherlands); Travis, Lois [Rubin Center for Cancer Survivorship and Department of Radiation Oncology, University of Rochester Medical Center, Rochester, New York (United States); Kwon, Deukwoo [Sylvester Comprehensive Cancer Center, University of Miami, Miami, Florida (United States); Morton, Lindsay M. [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Bethesda, Maryland (United States)

    2013-07-15

    Purpose: To provide dosimetric data for an epidemiologic study on the risk of second primary esophageal cancer among breast cancer survivors, by reconstructing the radiation dose incidentally delivered to the esophagus of 414 women treated with radiation therapy for breast cancer during 1943-1996 in North America and Europe. Methods and Materials: We abstracted the radiation therapy treatment parameters from each patient’s radiation therapy record. Treatment fields included direct chest wall (37% of patients), medial and lateral tangentials (45%), supraclavicular (SCV, 64%), internal mammary (IM, 44%), SCV and IM together (16%), axillary (52%), and breast/chest wall boosts (7%). The beam types used were {sup 60}Co (45% of fields), orthovoltage (33%), megavoltage photons (11%), and electrons (10%). The population median prescribed dose to the target volume ranged from 21 Gy to 40 Gy. We reconstructed the doses over the length of the esophagus using abstracted patient data, water phantom measurements, and a computational model of the human body. Results: Fields that treated the SCV and/or IM lymph nodes were used for 85% of the patients and delivered the highest doses within 3 regions of the esophagus: cervical (population median 38 Gy), upper thoracic (32 Gy), and middle thoracic (25 Gy). Other fields (direct chest wall, tangential, and axillary) contributed substantially lower doses (approximately 2 Gy). The cervical to middle thoracic esophagus received the highest dose because of its close proximity to the SCV and IM fields and less overlying tissue in that part of the chest. The location of the SCV field border relative to the midline was one of the most important determinants of the dose to the esophagus. Conclusions: Breast cancer patients in this study received relatively high incidental radiation therapy doses to the esophagus when the SCV and/or IM lymph nodes were treated, whereas direct chest wall, tangentials, and axillary fields contributed lower

  2. Dramatic response to high-dose icotinib in a lung adenocarcinoma patient after erlotinib failure.

    Science.gov (United States)

    Guan, Yin; Zhao, Hong; Meng, Jing; Yan, Xiang; Jiao, ShunChang

    2014-02-01

    Epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) retreatment is rarely administered for non-small cell lung cancer (NSCLC) patients who did not respond to previous TKI treatment. A high dose of TKI may overcome resistance to the standard dose of TKI and have different effectiveness toward cancer compared with the standard dose of TKI. This manuscript describes a dramatic and durable response to high-dose icotinib in a NSCLC patient who did not respond to a previous standard dose of erlotinib. The treatment extended the life of the patient for one additional year. A higher dose of icotinib deserves further study not only for patients whose therapy failed with the standard dose of TKI but also for newly diagnosed NSCLC patients with a sensitive mutation. Serial mutation testing during disease development is necessary for analysis and evaluation of EGFR TKI treatment. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Measurement-based Monte Carlo simulation of high definition dose evaluation for nasopharyngeal cancer patients treated by using intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Yeh, C.Y.; Tung, C.J.; Lee, C.C.; Lin, M.H.; Chao, T.C.

    2014-01-01

    Measurement-based Monte Carlo (MBMC) simulation using a high definition (HD) phantom was used to evaluate the dose distribution in nasopharyngeal cancer (NPC) patients treated with intensity modulated radiation therapy (IMRT). Around nasopharyngeal cavity, there exists many small volume organs-at-risk (OARs) such as the optic nerves, auditory nerves, cochlea, and semicircular canal which necessitate the use of a high definition phantom for accurate and correct dose evaluation. The aim of this research was to study the advantages of using an HD phantom for MBMC simulation in NPC patients treated with IMRT. The MBMC simulation in this study was based on the IMRT treatment plan of three NPC patients generated by the anisotropic analytical algorithm (AAA) of the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA, USA) using a calculation grid of 2 mm 2 . The NPC tumor was treated to a cumulative dose of 7000 cGy in 35 fractions using the shrinking-field sequential IMRT (SIMRT) method. The BEAMnrc MC Code was used to simulate a Varian EX21 linear accelerator treatment head. The HD phantom contained 0.5 × 0.5 × 1 mm 3 voxels for the nasopharyngeal area and 0.5 × 0.5 × 3 mm 3 for the rest of the head area. An efficiency map was obtained for the amorphous silicon aS1000 electronic portal imaging device (EPID) to adjust the weighting of each particle in the phase-space file for each IMRT beam. Our analysis revealed that small volume organs such as the eighth cranial nerve, semicircular canal, cochlea and external auditory canal showed an absolute dose difference of ≥200 cGy, while the dose difference for larger organs such as the parotid glands and tumor was negligible for the MBMC simulation using the HD phantom. The HD phantom was found to be suitable for Monte Carlo dose volume analysis of small volume organs. - Highlights: • HD dose evaluation for IMRT of NPC patients have been verified by the MC method. • MC results shows

  4. Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dyk, Pawel; Jiang, Naomi; Sun, Baozhou; DeWees, Todd A. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Fowler, Kathryn J.; Narra, Vamsi [Department of Diagnostic Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Garcia-Ramirez, Jose L.; Schwarz, Julie K. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Grigsby, Perry W., E-mail: pgrigsby@wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Gynecologic Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Alvin J. Siteman Cancer Center, Washington University School of Medicine, St Louis, Missouri (United States)

    2014-11-15

    Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

  5. Biological dose estimation for charged-particle therapy using an improved PHITS code coupled with a microdosimetric kinetic model

    International Nuclear Information System (INIS)

    Sato, Tatsuhiko; Watanabe, Ritsuko; Kase, Yuki; Niita, Koji; Sihver, Lembit

    2009-01-01

    High-energy heavy ions (HZE particles) have become widely used for radiotherapy of tumors owing to their high biological effectiveness. In the treatment planning of such charged-particle therapy, it is necessary to estimate not only physical but also biological dose, which is the product of physical dose and relative biological effectiveness (RBE). In the Heavy-ion Medical Accelerator in Chiba (HIMAC), the biological dose is estimated by a method proposed by Kanai et al., which is based on the linear-quadratic (LQ) model with its parameters α and β determined by the dose distribution in terms of the unrestricted linear energy transfer (LET). Thus, RBE is simply expressed as a function of LET in their model. However, RBE of HZE particles cannot be uniquely determined from their LET because of their large cross sections for high-energy δ-ray production. Hence, development of a biological dose estimation model that can explicitly consider the track structure of δ-rays around the trajectory of HZE particles is urgently needed. Microdosimetric quantities such as lineal energy y are better indexes for representing RBE of HZE particles in comparison to LET, since they can express the decrease of ionization densities around their trajectories due to the production of δ-rays. The difference of the concept between LET and y is illustrated in Figure 1. However, the use of microdosimetric quantities in computational dosimetry was severely limited because of the difficulty in calculating their probability densities (PDs) in macroscopic matter. We therefore improved the 3-dimensional particle transport simulation code PHITS, providing it with the capability of estimating the microdosimetric PDs in a macroscopic framework by incorporating a mathematical function that can instantaneously calculate the PDs around the trajectory of HZE particles with precision equivalent to a microscopic track-structure simulation. A new method for estimating biological dose from charged

  6. Algorithms for the optimization of RBE-weighted dose in particle therapy.

    Science.gov (United States)

    Horcicka, M; Meyer, C; Buschbacher, A; Durante, M; Krämer, M

    2013-01-21

    We report on various algorithms used for the nonlinear optimization of RBE-weighted dose in particle therapy. Concerning the dose calculation carbon ions are considered and biological effects are calculated by the Local Effect Model. Taking biological effects fully into account requires iterative methods to solve the optimization problem. We implemented several additional algorithms into GSI's treatment planning system TRiP98, like the BFGS-algorithm and the method of conjugated gradients, in order to investigate their computational performance. We modified textbook iteration procedures to improve the convergence speed. The performance of the algorithms is presented by convergence in terms of iterations and computation time. We found that the Fletcher-Reeves variant of the method of conjugated gradients is the algorithm with the best computational performance. With this algorithm we could speed up computation times by a factor of 4 compared to the method of steepest descent, which was used before. With our new methods it is possible to optimize complex treatment plans in a few minutes leading to good dose distributions. At the end we discuss future goals concerning dose optimization issues in particle therapy which might benefit from fast optimization solvers.

  7. Sub-second pencil beam dose calculation on GPU for adaptive proton therapy.

    Science.gov (United States)

    da Silva, Joakim; Ansorge, Richard; Jena, Rajesh

    2015-06-21

    Although proton therapy delivered using scanned pencil beams has the potential to produce better dose conformity than conventional radiotherapy, the created dose distributions are more sensitive to anatomical changes and patient motion. Therefore, the introduction of adaptive treatment techniques where the dose can be monitored as it is being delivered is highly desirable. We present a GPU-based dose calculation engine relying on the widely used pencil beam algorithm, developed for on-line dose calculation. The calculation engine was implemented from scratch, with each step of the algorithm parallelized and adapted to run efficiently on the GPU architecture. To ensure fast calculation, it employs several application-specific modifications and simplifications, and a fast scatter-based implementation of the computationally expensive kernel superposition step. The calculation time for a skull base treatment plan using two beam directions was 0.22 s on an Nvidia Tesla K40 GPU, whereas a test case of a cubic target in water from the literature took 0.14 s to calculate. The accuracy of the patient dose distributions was assessed by calculating the γ-index with respect to a gold standard Monte Carlo simulation. The passing rates were 99.2% and 96.7%, respectively, for the 3%/3 mm and 2%/2 mm criteria, matching those produced by a clinical treatment planning system.

  8. Fast optimization and dose calculation in scanned ion beam therapy

    International Nuclear Information System (INIS)

    Hild, S.; Graeff, C.; Trautmann, J.; Kraemer, M.; Zink, K.; Durante, M.; Bert, C.

    2014-01-01

    Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min

  9. EDTA chelation therapy alone and in combination with oral high-dose multivitamins and minerals for coronary disease: The factorial group results of the Trial to Assess Chelation Therapy.

    Science.gov (United States)

    Lamas, Gervasio A; Boineau, Robin; Goertz, Christine; Mark, Daniel B; Rosenberg, Yves; Stylianou, Mario; Rozema, Theodore; Nahin, Richard L; Terry Chappell, L; Lindblad, Lauren; Lewis, Eldrin F; Drisko, Jeanne; Lee, Kerry L

    2014-07-01

    Disodium ethylenediaminetetraacetic acid (EDTA) reduced adverse cardiac outcomes in a factorial trial also testing oral vitamins. This report describes the intent-to-treat comparison of the 4 factorial groups overall and in patients with diabetes. This was a double-blind, placebo-controlled, 2 × 2 factorial multicenter randomized trial of 1,708 post-myocardial infarction (MI) patients ≥50 years of age and with creatinine ≤2.0 mg/dL randomized to receive 40 EDTA chelation or placebo infusions plus 6 caplets daily of a 28-component multivitamin-multimineral mixture or placebo. The primary end point was a composite of total mortality, MI, stroke, coronary revascularization, or hospitalization for angina. Median age was 65 years, 18% were female, 94% were Caucasian, 37% were diabetic, 83% had prior coronary revascularization, and 73% were on statins. Five-year Kaplan-Meier estimates for the primary end point was 31.9% in the chelation + high-dose vitamin group, 33.7% in the chelation + placebo vitamin group, 36.6% in the placebo infusion + active vitamin group, and 40.2% in the placebo infusions + placebo vitamin group. The reduction in primary end point by double active treatment compared with double placebo was significant (hazard ratio 0.74, 95% CI 0.57-0.95, P = .016). In patients with diabetes, the primary end point reduction of double active compared with double placebo was more pronounced (hazard ratio 0.49, 95% CI 0.33-0.75, P < .001). In stable post-MI patients on evidence-based medical therapy, the combination of oral high-dose vitamins and chelation therapy compared with double placebo reduced clinically important cardiovascular events to an extent that was both statistically significant and of potential clinical relevance. Copyright © 2014 The Authors. Published by Mosby, Inc. All rights reserved.

  10. Clinical investigation of 131I therapy combined with low-dose lithium carbonate for Graves disease

    International Nuclear Information System (INIS)

    Xu Haiqing; Wu Bian

    2006-01-01

    Objective: To investigate the clinical curative effects of 131 I therapy combined with low-dose lithium carbonate for Graves disease. Methods: Patients with Graves disease took lithium carbonate (250 mg, once per day) orally for 5 weeks. Then they were treated with 131 I (doses=3.15 MBq(80 uCi)/g, based on 60%-70% of the thyroid size). We kept track from 6 to 24 months (averaging 14 months) and classified the results into three: cured, improved or no effect. Results: After a single cycle of 131 I therapy combined with low-dose lithium carbonate, 106 patients with Graves disease were cured, 28 were improved and 8 saw no effects, respectively 74.6%, 19.7% and 5.6% among the 142 patients. We then treated 23 of them with another 131 I therapy (without lithium carbonate). 10 of such were cured (43.5%), 8 were improved (34.8%) and the other 5 saw no effects. Among all patients, hypothyroidism was observed from 25(17.6%), 6 months after the first 131 I therapy. Conclusions: Notable curative results were observed from 131 I therapy combined with low-dose lithium carbonate for Graves disease. Moreover, the dosage of 131 I was therefore decreased, which also lowered the toxicity response. (authors)

  11. High Dose Oral Calcium Treatment in Patients with Vitamin D-dependent Rickets Type II

    Directory of Open Access Journals (Sweden)

    R Vakili

    2017-02-01

    Full Text Available BACKGROUND AND OBJECTIVE: Vitamin D-dependent rickets type II (VDDR2 is a rare genetic disorder caused by mutations in vitamin D receptor (VDR and leads to resistance to biological effects of calcitriol. Based on the type of mutation, this disease is resistant to calcitriol even at high doses of calcitriol and successful treatment of these patients requires hypocalcemic modification through administration of high doses of calcium and bypassing the intestinal defect in VDR signaling. In addition to the need for frequent hospitalization and high costs, intravenous administration of calcium is associated with complications and problems such as arrhythmia and sepsis, venous catheter infection and hypercalciuria. This study aims to report the positive treatment effects of high doses of oral calcium in 4 patients with vitamin D-dependent rickets type II. CASE REPORT: In this study, 4 patients with vitamin D-dependent rickets type II, diagnosed based on clinical and biochemical symptoms of rickets with alopecia, underwent therapy using high doses of oral calcium (300 mg/kg/day in pediatric endocrinology and metabolism center of Imam Reza hospital. After a short period, increased growth rate in height, strength and elasticity of muscles was observed in addition to biochemical improvements without serious side effects and even one patient started walking independently within the first week of therapy for the first time. Patients were regularly followed up in terms of height and weight, growth rate and biochemical factors including calcium, phosphorus and alkaline phosphatase every 3 months for one year. CONCLUSION: Regardless of the type of mutation in vitamin D receptor, it is suggested that a 3-6 months trial of high dose oral calcium be started in each patient with vitamin D-dependent rickets type II, particularly for patients whose disease was diagnosed at lower ages.

  12. Calculation of primary and secondary dose in proton therapy of brain tumors using Monte Carlo method

    International Nuclear Information System (INIS)

    Moghbel Esfahani, F.; Alamatsaz, M.; Karimian, A.

    2012-01-01

    High-energy beams of protons offer significant advantages for the treatment of deep-seated local tumors. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum - Bragg peak - near the end of range with a sharp falloff at the distal edge. Therefore, research must be done to investigate the possible negative and positive effects of using proton therapy as a treatment modality. In proton therapy, protons do account for the vast majority of dose. However, when protons travel through matter, secondary particles are created by the interactions of protons and matter en route to and within the patient. It is believed that secondary dose can lead to secondary cancer, especially in pediatric cases. Therefore, the focus of this work is determining both primary and secondary dose. Dose calculations were performed by MCNPX in tumoral and healthy parts of brain. The brain tumor has a 10 mm diameter and is located 16 cm under the skin surface. The brain was simulated by a cylindrical water phantom with the dimensions of 19 x 19cm 2 (length x diameter), with 0.5 cm thickness of plexiglass (C 4 H 6 O 2 ). Then beam characteristics were investigated to ensure the accuracy of the model. Simulations were initially validated with against packages such as SRIM/TRIM. Dose calculations were performed using different configurations to evaluate depth-dose profiles and dose 2D distributions.The results of the simulation show that the best proton energy interval, to cover completely the brain tumor, is from 152 to 154 MeV. (authors)

  13. Low-dose ion-based transmission radiography and tomography for optimization of carbon ion-beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Magallanes Hernandez, Lorena

    2017-02-21

    In the last few decades, ion-beam radiotherapy has emerged as a highly effective tumor treatment modality. Its success relies on the capability to precisely confine the prescribed dose within the target volume, due to the inverted depth-dose profile and the finite range featured by charged particles. However, to fully exploit the physical and biological advantages of ion-beams, it is necessary to prioritize on innovative imaging techniques to monitor the ion-range inside the patient. Main range uncertainties result from X-ray-based calibration of the ion relative Water Equivalent Path Length (rWEPL) during the planning phase, and patient anatomical or positioning variation during the treatment. In this thesis, low-dose carbon-ion transmissionimaging performed with a Residual Range Detector (RRD) is proposed as imaging strategy for actively scanned beam delivery facilities. It enables the verification of the beam range and the patient positioning with ion-radiographies (iRAD), and ion computed tomographies (iCT) can directly provide the ion stopping-power of the traversed tissue for treatment planning purposes. First experimental investigations aiming to minimize the imaging dose to the object are presented. The performance of the integration-mode multi-channel array of 61 parallel-plate ionization chambers (PPICs), interleaved with 3 mm thickness PMMA slabs, was thoroughly investigated for low-fluence irradiation. This characterization has been pursued in terms of beam-monitoring performance at the Heidelberg Ion-beam Therapy Center (HIT, Heidelberg, Germany), RRD signal-to-noise ratio (SNR), RRD charge-collection efficiency and drift voltage applied to the PPICs. Pixel-wise metrics for signal quality evaluation based on specific channel-charge features have been developed to support the visual assessment of the acquired images. Phantoms of different complexity and tissue-equivalent composition were imaged with high (5000 primaries per raster-scanning point (RP

  14. Low-dose ion-based transmission radiography and tomography for optimization of carbon ion-beam therapy

    International Nuclear Information System (INIS)

    Magallanes Hernandez, Lorena

    2017-01-01

    In the last few decades, ion-beam radiotherapy has emerged as a highly effective tumor treatment modality. Its success relies on the capability to precisely confine the prescribed dose within the target volume, due to the inverted depth-dose profile and the finite range featured by charged particles. However, to fully exploit the physical and biological advantages of ion-beams, it is necessary to prioritize on innovative imaging techniques to monitor the ion-range inside the patient. Main range uncertainties result from X-ray-based calibration of the ion relative Water Equivalent Path Length (rWEPL) during the planning phase, and patient anatomical or positioning variation during the treatment. In this thesis, low-dose carbon-ion transmissionimaging performed with a Residual Range Detector (RRD) is proposed as imaging strategy for actively scanned beam delivery facilities. It enables the verification of the beam range and the patient positioning with ion-radiographies (iRAD), and ion computed tomographies (iCT) can directly provide the ion stopping-power of the traversed tissue for treatment planning purposes. First experimental investigations aiming to minimize the imaging dose to the object are presented. The performance of the integration-mode multi-channel array of 61 parallel-plate ionization chambers (PPICs), interleaved with 3 mm thickness PMMA slabs, was thoroughly investigated for low-fluence irradiation. This characterization has been pursued in terms of beam-monitoring performance at the Heidelberg Ion-beam Therapy Center (HIT, Heidelberg, Germany), RRD signal-to-noise ratio (SNR), RRD charge-collection efficiency and drift voltage applied to the PPICs. Pixel-wise metrics for signal quality evaluation based on specific channel-charge features have been developed to support the visual assessment of the acquired images. Phantoms of different complexity and tissue-equivalent composition were imaged with high (5000 primaries per raster-scanning point (RP

  15. Relationship Between Radiation Therapy Dose and Outcome in Patients Treated With Neoadjuvant Chemoradiation Therapy and Surgery for Stage IIIA Non-Small Cell Lung Cancer: A Population-Based, Comparative Effectiveness Analysis

    International Nuclear Information System (INIS)

    Sher, David J.; Fidler, Mary Jo; Seder, Christopher W.; Liptay, Michael J.; Koshy, Matthew

    2015-01-01

    Purpose: To compare, using the National Cancer Database, survival, pathologic, and surgical outcomes in patients with stage IIIA non-small cell lung cancer treated with differential doses of neoadjuvant chemoradiation therapy, with the aim to discern whether radiation dose escalation was associated with a comparative effectiveness benefit and/or toxicity risk. Methods and Materials: Patients in the National Cancer Database with stage IIIA non-small cell lung cancer treated with neoadjuvant chemoradiation therapy and surgery between 1998 and 2005 were analyzed. Dose strata were divided between 36 to 45 Gy (low-dose radiation therapy, LD-RT), 45 to 54 Gy (inclusive, standard-dose, SD-RT), and 54 to 74 Gy (high-dose, HD-RT). Outcomes included overall survival, residual nodal disease, positive surgical margin status, hospital length of stay, and adverse surgical outcomes (30-day mortality or readmission). Results: The cohort consisted of 1041 patients: 233 (22%) LD-RT, 584 (56%) SD-RT, and 230 (22%) HD-RT. The median, 3-year, and 5-year overall survival outcomes were 34.9 months, 48%, and 37%, respectively. On univariable analysis, patients treated with SD-RT experienced prolonged overall survival (median 38.3 vs 31.8 vs 29.0 months for SD-RT, LD-RT, and HD-RT, respectively, P=.0089), which was confirmed on multivariable analysis (hazard ratios 0.77 and 0.81 vs LD and HD, respectively). Residual nodal disease was seen less often after HD-RT (25.5% vs 31.8% and 37.5% for HD-RT, LD-RT, and SD-RT, respectively, P=.0038). Patients treated with SD-RT had fewer prolonged hospital stays. There were no differences in positive surgical margin status or adverse surgical outcomes between the cohorts. Conclusions: Neoadjuvant chemoradiation therapy between 45 and 54 Gy was associated with superior survival in comparison with doses above and below this threshold. Although this conclusion is limited by selection bias, clear candidates for trimodality therapy do not seem to

  16. Relationship Between Radiation Therapy Dose and Outcome in Patients Treated With Neoadjuvant Chemoradiation Therapy and Surgery for Stage IIIA Non-Small Cell Lung Cancer: A Population-Based, Comparative Effectiveness Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sher, David J., E-mail: david_sher@rush.edu [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); Fidler, Mary Jo [Section of Medical Oncology, Rush University Medical Center, Chicago, Illinois (United States); Seder, Christopher W.; Liptay, Michael J. [Department of Cardiothoracic Surgery, Rush University Medical Center, Chicago, Illinois (United States); Koshy, Matthew [Department of Radiation and Cellular Oncology, University of Chicago, Chicago, Illinois (United States)

    2015-06-01

    Purpose: To compare, using the National Cancer Database, survival, pathologic, and surgical outcomes in patients with stage IIIA non-small cell lung cancer treated with differential doses of neoadjuvant chemoradiation therapy, with the aim to discern whether radiation dose escalation was associated with a comparative effectiveness benefit and/or toxicity risk. Methods and Materials: Patients in the National Cancer Database with stage IIIA non-small cell lung cancer treated with neoadjuvant chemoradiation therapy and surgery between 1998 and 2005 were analyzed. Dose strata were divided between 36 to 45 Gy (low-dose radiation therapy, LD-RT), 45 to 54 Gy (inclusive, standard-dose, SD-RT), and 54 to 74 Gy (high-dose, HD-RT). Outcomes included overall survival, residual nodal disease, positive surgical margin status, hospital length of stay, and adverse surgical outcomes (30-day mortality or readmission). Results: The cohort consisted of 1041 patients: 233 (22%) LD-RT, 584 (56%) SD-RT, and 230 (22%) HD-RT. The median, 3-year, and 5-year overall survival outcomes were 34.9 months, 48%, and 37%, respectively. On univariable analysis, patients treated with SD-RT experienced prolonged overall survival (median 38.3 vs 31.8 vs 29.0 months for SD-RT, LD-RT, and HD-RT, respectively, P=.0089), which was confirmed on multivariable analysis (hazard ratios 0.77 and 0.81 vs LD and HD, respectively). Residual nodal disease was seen less often after HD-RT (25.5% vs 31.8% and 37.5% for HD-RT, LD-RT, and SD-RT, respectively, P=.0038). Patients treated with SD-RT had fewer prolonged hospital stays. There were no differences in positive surgical margin status or adverse surgical outcomes between the cohorts. Conclusions: Neoadjuvant chemoradiation therapy between 45 and 54 Gy was associated with superior survival in comparison with doses above and below this threshold. Although this conclusion is limited by selection bias, clear candidates for trimodality therapy do not seem to

  17. Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

    International Nuclear Information System (INIS)

    Fiandra, Christian; Ragona, Riccardo; Ricardi, Umberto; Anglesio, Silvia; Giglioli, Francesca Romana

    2008-01-01

    The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K sat ) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

  18. Safety and efficacy of high-dose daptomycin as salvage therapy for severe gram-positive bacterial sepsis in hospitalized adult patients

    Directory of Open Access Journals (Sweden)

    Lai Chung-Chih

    2013-02-01

    Full Text Available Abstract Background Increasing the dosage of daptomycin may be advantageous in severe infection by enhancing bactericidal activity and pharmacodynamics. However, clinical data on using daptomycin at doses above 6 mg/kg in Asian population are limited. Methods A retrospective observational cohort study of all hospitalized adult patients treated with daptomycin (> 6 mg/kg for at least 72 hours was performed in Taiwan. Results A total of 67 patients (40 males with a median age of 57 years received a median dose of 7.61 mg/kg (range, 6.03-11.53 mg/kg of daptomycin for a median duration of 14 days (range, 3–53 days. Forty-one patients (61.2% were in intensive care units (ICU. Sites of infections included complicated skin and soft tissue infections (n = 16, catheter-related bacteremia (n = 16, endocarditis (n = 11, primary bacteremia (n = 10, osteomyelitis and septic arthritis (n = 9, and miscellaneous (n = 5. The median Pitt bacteremia score among the 54 (80.6% patients with bacteremia was 4. The most common pathogen was methicillin-resistant Staphylococcus aureus (n = 38. Fifty-nine patients (88.1% were treated with daptomycin after glycopepetide use. Overall, 52 (77.6% patients achieved clinical success. The all-cause mortality rate at 28 day was 35.8%. In multivariate analysis, the significant predictors of in-hospital mortality in 54 bacteremic patients were malignancies (P = 0.01 and ICU stay (P = 0.02. Adverse effects of daptomycin were generally well-tolerated, leading to discontinuation in 3 patients. Daptomycin-related creatine phosphokinase (CPK elevations were observed in 4 patients, and all received doses > 8 mg/kg. Conclusions Treatment with high dose daptomycin as salvage therapy was generally effective and safe in Taiwan. CPK level elevations were more frequent in patients with dose > 8 mg/kg.

  19. Phase I/II trial of single-fraction high-dose-rate brachytherapy-boosted hypofractionated intensity-modulated radiation therapy for localized adenocarcinoma of the prostate.

    Science.gov (United States)

    Myers, Michael A; Hagan, Michael P; Todor, Dorin; Gilbert, Lynn; Mukhopadhyay, Nitai; Randolf, Jessica; Heimiller, Jeffrey; Anscher, Mitchell S

    2012-01-01

    A Phase I/II protocol was conducted to examine the toxicity and efficacy of the combination of intensity-modulated radiation therapy (IMRT) with a single-fraction high-dose-rate (HDR) brachytherapy implant. From 2001 through 2006, 26 consecutive patients were treated on the trial. The primary objective was to demonstrate a high rate of completion without experiencing a treatment-limiting toxicity. Eligibility was limited to patients with T stage ≤2b, prostate-specific antigen (PSA) ≤20, and Gleason score ≤7. Treatment began with a single HDR fraction of 6Gy to the entire prostate and 9Gy to the peripheral zone, followed by IMRT optimized to deliver in 28 fractions with a normalized total dose of 70Gy. Patients received 50.4Gy to the pelvic lymph node. The prostate dose (IMRT and HDR) resulted in an average biologic equivalent dose >128Gy (α/β=3). Patients whose pretreatment PSA was ≥10ng/mL, Gleason score 7, or stage ≥T2b received short-term androgen ablation. Median followup was 53 months (9-68 months). There were no biochemical failures by either the American Society of Therapeutic Radiology and Oncology or the Phoenix definitions. The median nadir PSA was 0.32ng/mL. All the 26 patients completed the treatment as prescribed. The rate of Grade 3 late genitourinary toxicity was 3.8% consisting of a urethral stricture. There was no other Grade 3 or 4 genitourinary or gastrointestinal toxicities. Single-fraction HDR-boosted IMRT is a safe effective method of dose escalation for localized prostate cancer. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. Dose measurement techniques for high-energy photon and electron radiation

    International Nuclear Information System (INIS)

    Hohlfeld, K.; Roos, M.

    1992-08-01

    By law the Federal Institute of Physics and Technology (PTB) has been assigned the tasks of representing, preserving and passing on dose units. The analogous continuation of these tasks consists in improving, at the user level, dosimetry techniques in radiation therapy for the benefit of patients. The PTB had an essential share in working out the scientific foundations of dosimetry for high-energy radiation, and the corresponding DIN standards were established with the PTB playing a prominent part. The seminar aimed at presenting the measuring techniques fixed in the new DIN standard 6800 part 2 'Dose measurement techniques according to the probe method - ionization dosimetry', to discuss their physical background and practical implications resulting from them. (orig.) [de

  1. High-dose-rate stereotactic body radiation therapy for postradiation therapy locally recurrent prostatic carcinoma: Preliminary prostate-specific antigen response, disease-free survival, and toxicity assessment.

    Science.gov (United States)

    Fuller, Donald B; Wurzer, James; Shirazi, Reza; Bridge, Stephen S; Law, Jonathan; Mardirossian, George

    2015-01-01

    Patients with locally recurrent adenocarcinoma of the prostate following radiation therapy (RT) present a challenging problem. We prospectively evaluated the use of "high-dose-rate-like" prostate stereotactic body RT (SBRT) salvage for this circumstance, evaluating prostate-specific antigen response, disease-free survival, and toxicity. Between February 2009 and March 2014, 29 patients with biopsy-proven recurrent locally prostate cancer >2 years post-RT were treated. Median prior RT dose was 73.8 Gy and median interval to SBRT salvage was 88 months. Median recurrence Gleason score was 7 (79% was ≥7). Pre-existing RT toxicity >grade 1 was a reason for exclusion. Magnetic resonance imaging-defined prostate volume including any suspected extraprostatic extension, comprising the planning target volume. A total of 34 Gy/5 fractions was given, delivering a heterogeneous, high-dose-rate-like dose-escalation pattern. Toxicities were assessed using Common Terminology Criteria for Adverse Events, version 3.0, criteria. Twenty-nine treated patients had a median 24-month follow-up (range, 3-60 months). A median pre-SBRT salvage baseline prostate-specific antigen level of 3.1 ng/mL decreased to 0.65 ng/mL and 0.16 ng/mL at 1 and 2 years, respectively. Actuarial 2-year biochemical disease-free survival measured 82%, with no local failures. Toxicity >grade 1 was limited to the genitourinary domain, with 18% grade 2 or higher and 7% grade 3 or higher. No gastrointestinal toxicity >grade 1 occurred. Two-year disease-free survival is encouraging, and the prostate-specific antigen response kinetic appears comparable with that seen in de novo patients treated with SBRT, albeit still a preliminary finding. Grade ≥2 genitourinary toxicity was occasionally seen with no obvious predictive factor. Noting that our only brachytherapy case was 1 of the 2 cases with ≥grade 3 genitourinary toxicity, caution is recommended treating these patients. SBRT salvage of post-RT local recurrence

  2. High-dose intensity modulated radiation therapy for prostate cancer: early toxicity and biochemical outcome in 772 patients

    International Nuclear Information System (INIS)

    Zelefsky, Michael J.; Fuks, Zvi; Hunt, Margie; Yamada, Yoshiya; Marion, Christine; Ling, C. Clifton; Amols, Howard; Venkatraman, E.S.; Leibel, Steven A.

    2002-01-01

    Purpose: To report the acute and late toxicity and preliminary biochemical outcomes in 772 patients with clinically localized prostate cancer treated with high-dose intensity-modulated radiotherapy (IMRT). Methods and Materials: Between April 1996 and January 2001, 772 patients with clinically localized prostate cancer were treated with IMRT. Treatment was planned using an inverse-planning approach, and the desired beam intensity profiles were delivered by dynamic multileaf collimation. A total of 698 patients (90%) were treated to 81.0 Gy, and 74 patients (10%) were treated to 86.4 Gy. Acute and late toxicities were scored by the Radiation Therapy Oncology Group morbidity grading scales. PSA relapse was defined according to The American Society of Therapeutic Radiation Oncology Consensus Statement. The median follow-up time was 24 months (range: 6-60 months). Results: Thirty-five patients (4.5%) developed acute Grade 2 rectal toxicity, and no patient experienced acute Grade 3 or higher rectal symptoms. Two hundred seventeen patients (28%) developed acute Grade 2 urinary symptoms, and one experienced urinary retention (Grade 3). Eleven patients (1.5%) developed late Grade 2 rectal bleeding. Four patients (0.1%) experienced Grade 3 rectal toxicity requiring either one or more transfusions or a laser cauterization procedure. No Grade 4 rectal complications have been observed. The 3-year actuarial likelihood of ≥ late Grade 2 rectal toxicity was 4%. Seventy-two patients (9%) experienced late Grade 2 urinary toxicity, and five (0.5%) developed Grade 3 urinary toxicity (urethral stricture). The 3-year actuarial likelihood of ≥ late Grade 2 urinary toxicity was 15%. The 3-year actuarial PSA relapse-free survival rates for favorable, intermediate, and unfavorable risk group patients were 92%, 86%, and 81%, respectively. Conclusions: These data demonstrate the feasibility of high-dose IMRT in a large number of patients. Acute and late rectal toxicities seem to be

  3. External beam radiation therapy and a low-dose-rate brachytherapy boost without or with androgen deprivation therapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Strom, Tobin J.; Hutchinson, Sean Z.; Shrinath, Kushagra; Cruz, Alex A.; Figura, Nicholas B.; Nethers, Kevin; Biagioli, Matthew C.; Fernandez, Daniel C.; Heysek, Randy V.; Wilder, Richard B., E-mail: richard.wilder@moffitt.org [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States)

    2014-07-15

    Purpose: To assess outcomes with external beam radiation therapy (EBRT) and a low-dose-rate (LDR) brachytherapy boost without or with androgen deprivation therapy (ADT) for prostate cancer. Materials and Methods: From January 2001 through August 2011, 120 intermediate-risk or high-risk prostate cancer patients were treated with EBRT to a total dose of 4,500 cGy in 25 daily fractions and a palladium-103 LDR brachytherapy boost of 10,000 cGy (n = 90) or an iodine-125 LDR brachytherapy boost of 11,000 cGy (n = 30). ADT, consisting of a gonadotropin-releasing hormone agonist ± an anti-androgen, was administered to 29/92 (32%) intermediate-risk patients for a median duration of 4 months and 26/28 (93%) high-risk patients for a median duration of 28 months. Results: Median follow-up was 5.2 years (range, 1.1-12.8 years). There was no statistically-significant difference in biochemical disease-free survival (bDFS), distant metastasis-free survival (DMFS), or overall survival (OS) without or with ADT. Also, there was no statistically-significant difference in bDFS, DMFS, or OS with a palladium-103 vs. an iodine-125 LDR brachytherapy boost. Conclusions: There was no statistically-significant difference in outcomes with the addition of ADT, though the power of the current study was limited. The Radiation Therapy Oncology Group 0815 and 0924 phase III trials, which have accrual targets of more than 1,500 men, will help to clarify the role ADT in locally-advanced prostate cancer patients treated with EBRT and a brachytherapy boost. Palladium-103 and iodine-125 provide similar bDFS, DMFS, and OS. (author)

  4. The Clatterbridge high-energy neutron therapy facility: specification and performance

    International Nuclear Information System (INIS)

    Bonnett, D.E.; Blake, S.W.; Shaw, J.E.; Bewley, D.K.

    1988-01-01

    A high energy neutron therapy facility has been installed at the Douglas Cyclotron Centre, Clatterbridge Hospital Merseyside, to extend M.R.C. clinical trials of fast neutrons. The neutron beam is produced by bombarding a beryllium target with 62 MeV protons. The target is isocentrically mounted with potential for 360 0 rotation, with a fully variable collimator, giving a range of rectilinear field sizes from 5 cm x 5 cm to 30 cm x 30 cm. Basic neutron beam data including output, field flatness, penumbra and depth-dose data have been measured. For a 10 cm x 10 cm field, 50% depth dose occurs at 16.2 cm in water and output is 1.63 cGy μ A -1 min -1 at maximum dose depth. Effectiveness of the target shielding and neutron-induced radioactivity in the treatment head were also measured. It is concluded that the equipment meets design specifications and fully satisfies criticisms of earlier neutron therapy equipment. A full radiation survey showed that radiation levels present no significant staff hazard. (UK)

  5. Dose discrepancy between planning system estimation and measurement in spine stereotactic body radiation therapy: A case report

    International Nuclear Information System (INIS)

    Arumugam, Sankar; Xing, Aitang; Vial Philip; Berry Megan; Ochoa, Cesar; Beeksma, Bradley

    2017-01-01

    Stereotactic body radiation therapy (SBRT) to treat spinal metastases has shown excellent clinical outcomes for local control. High dose gradients wrapping around spinal cord make this treatment technically challenging. In this work, we present a spine SBRT case where a dosimetric error was identified during pre-treatment dosimetric quality assurance (QA). A patient with metastasis in T7 vertebral body consented to undergo SBRT. A dual arc volumetric modulated arc therapy plan was generated on the Pinnacle treatment planning system (TPS) with a 6 MV Elekta machine using gantry control point spacing of 4°. Standard pre-treatment QA measurements were performed, including ArcCHECK, ion chamber in CTV and spinal cord (SC) region and film measurements in multiple planes. While the dose measured at CTV region showed good agreement with TPS, the dose measured to the SC was significantly higher than reported by TPS in the original and repeat plans. Acceptable agreement was only achieved when the gantry control point spacing was reduced to 3°. A potentially harmful dose error was identified by pre-treatment QA. TPS parameter settings used safely in conventional treatments should be re-assessed for complex treatments.

  6. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    OpenAIRE

    Mihir Kothari

    2014-01-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  7. Occlusion-amblyopia following high dose oral levodopa combined with part time patching.

    Science.gov (United States)

    Kothari, Mihir

    2014-12-01

    Part time occlusion therapy is not reported to cause occlusion (reverse) amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  8. Dose Specification and Quality Assurance of Radiation Therapy Oncology Group Protocol 95-17; a Cooperative Group Study of Iridium-192 Breast Implants as Sole Therapy

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S.; Hanson, W.F.; O'Meara, Elizabeth; Kuske, Robert R.; Arthur, Douglas; Rabinovitch, Rachel; White, Julia; Wilenzick, Raymond M.; Harris, Irene; Tailor, Ramesh C.

    2007-01-01

    Purpose: The Radiation Therapy Oncology Group (RTOG) protocol 95-17 was a Phase I/II trial to evaluate multicatheter brachytherapy as the sole method of adjuvant breast radiotherapy for Stage I/II breast carcinoma after breast-conserving surgery. Low- or high-dose-rate sources were allowed. Dose prescription and treatment evaluation were based on recommendations in the International Commission on Radiation Units and Measurements (ICRU), Report 58 and included the parameters mean central dose (MCD), average peripheral dose, dose homogeneity index (DHI), and the dimensions of the low- and high-dose regions. Methods and Materials: Three levels of quality assurance were implemented: (1) credentialing of institutions was required before entering patients into the study; (2) rapid review of each treatment plan was conducted before treatment; and (3) retrospective review was performed by the Radiological Physics Center in conjunction with the study chairman and RTOG dosimetry staff. Results: Credentialing focused on the accuracy of dose calculation algorithm and compliance with protocol guidelines. Rapid review was designed to identify and correct deviations from the protocol before treatment. The retrospective review involved recalculation of dosimetry parameters and review of dose distributions to evaluate the treatment. Specifying both central and peripheral doses resulted in uniform dose distributions, with a mean dose homogeneity index of 0.83 ± 0.06. Conclusions: Vigorous quality assurance resulted in a high-quality study with few deviations; only 4 of 100 patients were judged as representing minor variations from protocol, and no patient was judged as representing major deviation. This study should be considered a model for quality assurance of future trials

  9. The feasibility and safety of high-intensity focused ultrasound combined with low-dose external beam radiotherapy as supplemental therapy for advanced prostate cancer following hormonal therapy.

    Science.gov (United States)

    Wu, Rui-Yi; Wang, Guo-Min; Xu, Lei; Zhang, Bo-Heng; Xu, Ye-Qing; Zeng, Zhao-Chong; Chen, Bing

    2011-05-01

    The aim of this study was to investigate the feasibility and safety of high-intensity focused ultrasound (HIFU) combined with (+) low-dose external beam radiotherapy (LRT) as supplemental therapy for advanced prostate cancer (PCa) following hormonal therapy (HT). Our definition of HIFU+LRT refers to treating primary tumour lesions with HIFU in place of reduced field boost irradiation to the prostate, while retaining four-field box irradiation to the pelvis in conventional-dose external beam radiotherapy (CRT). We performed a prospective, controlled and non-randomized study on 120 patients with advanced PCa after HT who received HIFU, CRT, HIFU+LRT and HT alone, respectively. CT/MR imaging showed the primary tumours and pelvic lymph node metastases visibly shrank or even disappeared after HIFU+LRT treatment. There were significant differences among four groups with regard to overall survival (OS) and disease-specific survival (DSS) curves (P = 0.018 and 0.015). Further comparison between each pair of groups suggested that the long-term DSS of the HIFU+LRT group was higher than those of the other three groups, but there was no significant difference between the HIFU+LRT group and the CRT group. Multivariable Cox's proportional hazard model showed that both HIFU+LRT and CRT were independently associated with DSS (P = 0.001 and 0.035) and had protective effects with regard to the risk of death. Compared with CRT, HIFU+LRT significantly decreased incidences of radiation-related late gastrointestinal (GI) and genitourinary (GU) toxicity grade ≥ II. In conclusion, long-term survival of patients with advanced PCa benefited from strengthening local control of primary tumour and regional lymph node metastases after HT. As an alternative to CRT, HIFU+LRT showed good efficacy and better safety.

  10. Radiation therapy and concurrent fixed dose amifostine with escalating doses of twice-weekly gemcitabine in advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Yavuz, A. Aydin; Aydin, Fazil; Yavuz, Melek N.; Ilis, Esra; Ozdemir, Feyyaz

    2001-01-01

    Purpose: To determine the maximum tolerated dose (MTD) and dose-limiting toxicity (DLT) of twice-weekly gemcitabine (TW-G) when administered in conjunction with fixed dose amifostine (A) during external radiotherapy (RT) in patients with advanced pancreatic cancer. Methods and Materials: Ten patients with previously untreated, locally advanced, or asymptomatic-metastatic pancreatic adenocarcinoma were enrolled in this study. RT was delivered by using the standard four-field technique (1.8 Gy daily fractions, 45 Gy followed by a boost of 5.4 Gy, in 5-1/2 weeks). The starting dose of TW-G was 60 mg/m 2 (i.v., 30-min infusion), which is equal to the upper limit of previously reported MTD of TW-G when given without A during RT. A was given just before the TW-G, at a fixed dose of 340 mg/m 2 (i.v., rapid infusion). TW-G doses were escalated by 30-mg/m 2 increments in successive cohorts of 3 to 6 additional patients until DLT was observed. Toxicities were graded using the Radiation Therapy Oncology Group and National Cancer Institute Common Toxicity Criteria, version 2.0. Results: In general, therapy was well tolerated in patients treated at the first two dose levels of 60 mg/m 2 and 90 mg/m 2 . The DLT of TW-G given in conjunction with A during RT were neutropenia, thrombocytopenia, and nausea/vomiting at the dose level of 120 mg/m 2 . Of the 10 patients eligible for a median follow-up of 10 months, 5 remain alive; 1 complete responder, 3 partial responders, and 1 with stable disease. Conclusion: A dose of TW-G at a level of 90 mg/m 2 produced tolerable toxicity and it may possess significant activity when delivered in conjunction with 340 mg/m 2 dose of A during RT of the upper abdomen. Due to the higher MTD of TW-G seen in our study, we consider that the A supplementation may optimize the therapeutic index of TW-G-based chemoradiotherapy protocols in patients with pancreatic carcinoma

  11. Long-term reversibility of renal dysfunction associated to light chain deposition disease with bortezomib and dexamethasone and high dose therapy and autologous stem cell transplantation

    Directory of Open Access Journals (Sweden)

    Tomás J. González-López

    2011-11-01

    Full Text Available A 63-year-old woman presented with progressive renal insufficiency, until a glomerular filtration rate (GFR of 12 mL/min. A renal biopsy demonstrated glomerular deposition of immunoglobulin k light chain. The presence of a small population of monoclonal plasmacytes producing an only light k monoclonal component was demonstrated and Bortezomib and Dexamethasone (BD was provided as initial therapy. After seven courses of therapy, renal function improved without dialysis requirements up to a GFR 31 mL/min. Under hematological complete response (HCR the patient underwent high dose of melphalan (HDM and autologous peripheral blood stem cell transplant. Fifty-four months later the patient remains in HCR and the GFR has progressively improved up to 48 mL/min. This report describes a notably renal function improvement in a patient with Light Chain Deposition Disease after therapy with BD followed by HDM, which can support this treatment as a future option for these patients.

  12. The potential influence of cell protectors for dose escalation in cancer therapy: an analysis of amifostine

    International Nuclear Information System (INIS)

    McCumber, Linda M.

    2004-01-01

    The attempt to increase the therapeutic ratio in an effort to improve survival or quality of life is the goal of modern cancer therapy. It is commonly accepted that local and systemic tumor control would increase if the dose intensity of antineoplastic drugs, radiation therapy, or the combination were increased. Radiation dose escalation using intensity-modulated radiation therapy (IMRT), accelerated or hypofractionated radiation schemes, and multidrug chemotherapy regimens are being used to try to increase tumor kill while inflicting minimal injury to normal tissue. Modern chemoradiation techniques have led to improved local regional control and increased cure rates, but the potentially severe and debilitating adverse effects of the therapies prevent them from reaching the ultimate goal of curing the disease while leaving the patient with a good quality of life. Cell protectants such as amifostine function by reducing the effects of therapy on normal cells while maintaining tumor sensitivity to the therapy. In various studies, amifostine has been analyzed and appears to be a potentially powerful adjuvant to current cancer therapy. Administering amifostine may allow dose escalation with less or equal risk to surrounding normal tissues. This could improve therapeutic efficacy, survival, and quality of life for cancer patients

  13. Temperature mapping and thermal dose calculation in combined radiation therapy and 13.56 MHz radiofrequency hyperthermia for tumor treatment

    Science.gov (United States)

    Kim, Jung Kyung; Prasad, Bibin; Kim, Suzy

    2017-02-01

    To evaluate the synergistic effect of radiotherapy and radiofrequency hyperthermia therapy in the treatment of lung and liver cancers, we studied the mechanism of heat absorption and transfer in the tumor using electro-thermal simulation and high-resolution temperature mapping techniques. A realistic tumor-induced mouse anatomy, which was reconstructed and segmented from computed tomography images, was used to determine the thermal distribution in tumors during radiofrequency (RF) heating at 13.56 MHz. An RF electrode was used as a heat source, and computations were performed with the aid of the multiphysics simulation platform Sim4Life. Experiments were carried out on a tumor-mimicking agar phantom and a mouse tumor model to obtain a spatiotemporal temperature map and thermal dose distribution. A high temperature increase was achieved in the tumor from both the computation and measurement, which elucidated that there was selective high-energy absorption in tumor tissue compared to the normal surrounding tissues. The study allows for effective treatment planning for combined radiation and hyperthermia therapy based on the high-resolution temperature mapping and high-precision thermal dose calculation.

  14. Perioperative single high dose ATG-Fresenius S administration as induction immunosuppressive therapy in cadaveric renal transplantation--preliminary results.

    Science.gov (United States)

    Samsel, R; Chmura, A; Włodarczyk, Z; Wyzgał, J; Cieciura, T; Lagiewska, B; Pliszczyński, J; Korczak, G; Lazowski, T; Paczek, L; Wałaszewski, J; Lao, M; Rowiński, W

    1999-01-01

    Monoclonal and polyclonal antilymphocyte antibodies have been used successfully in organ transplantation as induction therapy and in the treatment of acute graft rejection. Used for induction the medication is generally given for the first 7-10 days. The aim of this study was to assess the safety and efficacy of single high dose (9 mg/kg) ATG Fresenius S given perioperatively, before revascularization, to kidney allograft recipients. During last twelve months seventy six, first cadaveric kidney adult recipients were included into the study in two centers (center A-64, center B-12). All patients received triple drug immunosuppression (Neoral, steroids and Cellcept which was replaced by azathioprine after 4 months), and were randomized to receive ATG or not. The follow-up period ranged from 1 month up to 1 year. The preliminary results are very promising, the rejection rate in bolus group was significantly lower than in control. No significant side effects or serious adverse events in both groups were observed.

  15. Evolution of dose calculation models for proton-therapy treatment planning

    International Nuclear Information System (INIS)

    Vidal, Marie

    2011-01-01

    This work was achieved in collaboration between the Institut Curie proton-therapy Center of Orsay (ICPO), the DOSIsoft company and the CREATIS laboratory, in order to develop a new dose calculation model for the new ICPO treatment room. A new accelerator and gantry room from the IBA company were installed during the up-grade project of the proton-therapy center, with the intention of enlarging the cancer localizations treated at ICPO. Developing a package of methods and new dose calculation algorithms to adapt them to the new specific characteristics of the delivered beams by the IBA system is the first goal of this PhD work. They all aim to be implemented in the DOSIsoft treatment planning software, Isogray. First, the double scattering technique is treated in taking into account major differences between the IBA system and the ICPO fixed beam lines passive system. Secondly, a model is explored for the scanned beams modality. The second objective of this work is improving the Ray-Tracing and Pencil-Beam dose calculation models already in use. For the double scattering and uniform scanning techniques, the patient personalized collimator at the end of the beam line causes indeed a patient dose distribution contamination. A reduction method of that phenomenon was set up for the passive beam system. An analytical model was developed which describes the contamination function with parameters validated through Monte-Carlo simulations on the GATE platform. It allows us to apply those methods to active scanned beams [fr

  16. Impact of Drug Therapy, Radiation Dose, and Dose Rate on Renal Toxicity Following Bone Marrow Transplantation

    International Nuclear Information System (INIS)

    Cheng, Jonathan C.; Schultheiss, Timothy E.; Wong, Jeffrey Y.C.

    2008-01-01

    Purpose: To demonstrate a radiation dose response and to determine the dosimetric and chemotherapeutic factors that influence the incidence of late renal toxicity following total body irradiation (TBI). Methods and Materials: A comprehensive retrospective review was performed of articles reporting late renal toxicity, along with renal dose, fractionation, dose rate, chemotherapy regimens, and potential nephrotoxic agents. In the final analysis, 12 articles (n = 1,108 patients), consisting of 24 distinct TBI/chemotherapy conditioning regimens were included. Regimens were divided into three subgroups: adults (age ≥18 years), children (age <18 years), and mixed population (both adults and children). Multivariate logistic regression was performed to identify dosimetric and chemotherapeutic factors significantly associated with late renal complications. Results: Individual analysis was performed on each population subgroup. For the purely adult population, the only significant variable was total dose. For the mixed population, the significant variables included total dose, dose rate, and the use of fludarabine. For the pediatric population, only the use of cyclosporin or teniposide was significant; no dose response was noted. A logistic model was generated with the exclusion of the pediatric population because of its lack of dose response. This model yielded the following significant variables: total dose, dose rate, and number of fractions. Conclusion: A dose response for renal damage after TBI was identified. Fractionation and low dose rates are factors to consider when delivering TBI to patients undergoing bone marrow transplantation. Drug therapy also has a major impact on kidney function and can modify the dose-response function

  17. High-dose radioiodine treatment for differentiated thyroid carcinoma is not associated with change in female fertility or any genetic risk to the offspring

    International Nuclear Information System (INIS)

    Bal, Chandrasekhar; Kumar, Ajay; Tripathi, Madhavi; Chandrashekar, Narayana; Phom, Hentok; Murali, Nadig R.; Chandra, Prem; Pant, Gauri S.

    2005-01-01

    Background: We tried to evaluate the female fertility and genetic risk to the offspring from the exposure to high-dose 131 I by assessing the pregnancy outcomes and health status of the children of female patients with differentiated thyroid cancer who had received therapeutic doses of 131 I. Materials and Methods: From 1967 to 2002, a total of 1,282 women had been treated with 131 I. Of these patients, 692 (54%) were in the reproductive age group (18-45 years). Forty women had a total of 50 pregnancies after high-dose 131 I. Age at presentation ranged from 16 to 36 years (mean, 23 ± 4 years). Histopathology was papillary thyroid cancer in 32 cases and follicular thyroid cancer in 8 cases. Results: Single high-dose therapy was given in 30 cases, 2 doses were given in 7 cases, 3 doses were given in 2 cases, and four doses were given in 1 case in which lung metastases had occurred. In 37 patients (92%), disease was successfully ablated before pregnancy. Ovarian absorbed-radiation dose calculated by the MIRD method ranged from 3.5 to 60 cGy (mean, 12 ± 11 cGy). The interval between 131 I therapy and pregnancy varied from 7 to 120 months (37.4 ± 28.2 months). Three spontaneous abortions occurred in 2 women. Forty-seven babies (20 females and 27 males) were born. Forty-four babies were healthy with normal birth weight and normal developmental milestones. Twenty women delivered their first baby after 131 I therapy. The youngest child in our series is 11 months of age, and the oldest is 8.5 years of age. Conclusions: Female fertility is not affected by high-dose radioiodine treatment, and the therapy does not appear to be associated with any genetic risks to the offspring

  18. Measurement of the three-dimensional distribution of radiation dose in grid therapy

    International Nuclear Information System (INIS)

    Trapp, J V; Warrington, A P; Partridge, M; Philps, A; Glees, J; Tait, D; Ahmed, R; Leach, M O; Webb, S

    2004-01-01

    A single large dose of megavoltage x-rays delivered through a grid is currently being utilized by some centres for palliative radiotherapy treatments of large tumours. In this note, we investigate the dosimetry of grid therapy using two-dimensional film dosimetry and three-dimensional gel dosimetry. It is shown that the radiation dose is attenuated more rapidly with depth in a grid field than an open field, and that even shielded regions receive approximately 25% of the dose to the unshielded areas. (note)

  19. Early quality of life outcomes in patients with prostate cancer managed by high-dose-rate brachytherapy as monotherapy

    International Nuclear Information System (INIS)

    Komiya, Akira; Fujiuchi, Yasuyoshi; Ito, Takatoshi

    2013-01-01

    The purpose of this study was to evaluate the early quality of life outcomes in prostate cancer patients managed by high-dose-rate brachytherapy as monotherapy. A total of 51 patients with cT1c-T3aN0M0 prostate cancer treated between July 2007 and January 2010 were included in this study. The average age was 69?years, and the average initial serum prostate-specific antigen was 10.98?ng/mL. A total of 25, 18 and eight patients were considered to be low, intermediate and high risk, respectively. All patients received one implant of Ir-192 and seven fractions of 6.5?Gy within 3.5?days for a total prescribed dose of 45.5?Gy. For high-risk prostate cancer, neoadjuvant androgen deprivation therapy was carried out for at least 6?months, and continued after high-dose-rate brachytherapy. Quality of life outcomes were measured by using the International Prostate Symptom Score, the Functional Assessment of Cancer Therapy-Prostate and the International Index of Erectile Function Questionnaire. The oncological outcome was assessed by serum prostate-specific antigen and diagnostic imaging. Adverse events were also recorded. The Functional Assessment of Cancer Therapy-Prostate scores decreased for a few months after high-dose-rate brachytherapy, and recovered to pretreatment condition thereafter. The International Prostate Symptom Score significantly increased 2?weeks after treatment for each of its items and their sum, and it returned to baseline after 12?weeks. Sexual function decreased at 2 and 4?weeks, and recovered after 12?weeks. Severe complications were rare. Within a median follow up of 17.2?months, two patients showed a prostate-specific antigen recurrence. High-dose-rate brachytherapy for prostate cancer is a feasible treatment modality with acceptable toxicity and only a limited impact on the quality of life. (author)

  20. Initial results of a phase II trial of high dose radiation therapy, 5-fluorouracil, and cisplatin for patients with anal cancer (E4292): an eastern cooperative oncology group study

    International Nuclear Information System (INIS)

    Martenson, James A.; Lipsitz, Stuart R.; Wagner, Henry; Kaplan, Edward H.; Otteman, Larry A.; Schuchter, Lynn M.; Mansour, Edward G.; Talamonti, Mark S.; Benson, Al Bowen

    1996-01-01

    Purpose: A prospective clinical trial was performed to assess the response and toxicity associated with the use of high dose radiation therapy, 5-fluorouracil, and cisplatin in patients with anal cancer. Methods and Materials: Patients with anal cancer without distant metastasis were eligible for this study. Radiation therapy consisted of 59.4 Gy in 33 fractions; a 2 week break in treatment was taken after 36 Gy had been given. A treatment of 5-fluorouracil, 1,000 mg/m 2 per day intravenously, was given for the first 4 days of radiation therapy, and cisplatin, 75 mg/m 2 intravenously, was given on day 1 of radiation therapy. A second course of 5-fluorouracil and cisplatin was given after 36 Gy of radiation, when the radiation therapy was resumed. Results: Nineteen patients entered this study and received treatment. Thirteen (68%) had a complete response, 5 (26%) had a partial response, and 1 (5%) had stable disease. The patient with stable disease and one of the patients with a partial response had complete disappearance of tumor more than 8 weeks after completion of radiation therapy. Fifteen patients had toxicity of Grade 3 or higher: the worst toxicity was Grade 3 in eight patients, Grade 4 in six patients, and Grade 5 in one patient. The most common form of toxicity of Grade 3 or higher was hematologic. The one lethal toxicity was due to pseudomembranous colitis, which was a complication of antibiotic therapy for a urinary tract infection. Conclusion: Radiation therapy, cisplatin, and 5-fluorouracil resulted in an overall response rate of 95%. Significant toxicity occurred, an indication that this regimen is near the maximal tolerated dose. A Phase III clinical trial is planned in which radiation therapy, cisplatin, and 5-fluorouracil will be used as an experimental arm

  1. The radiobiology of boron neutron capture therapy: Are ''photon-equivalent'' doses really photon-equivalent?

    International Nuclear Information System (INIS)

    Coderre, J.A.; Diaz, A.Z.; Ma, R.

    2001-01-01

    Boron neutron capture therapy (BNCT) produces a mixture of radiation dose components. The high-linear energy transfer (LET) particles are more damaging in tissue than equal doses of low-LET radiation. Each of the high-LET components can multiplied by an experimentally determined factor to adjust for the increased biological effectiveness and the resulting sum expressed in photon-equivalent units (Gy-Eq). BNCT doses in photon-equivalent units are based on a number of assumptions. It may be possible to test the validity of these assumptions and the accuracy of the calculated BNCT doses by 1) comparing the effects of BNCT in other animal or biological models where the effects of photon radiation are known, or 2) if there are endpoints reached in the BNCT dose escalation clinical trials that can be related to the known response to photons of the tissue in question. The calculated Gy-Eq BNCT doses delivered to dogs and to humans with BPA and the epithermal neutron beam of the Brookhaven Medical Research Reactor were compared to expected responses to photon irradiation. The data indicate that Gy-Eq doses in brain may be underestimated. Doses to skin are consistent with the expected response to photons. Gy-Eq doses to tumor are significantly overestimated. A model system of cells in culture irradiated at various depths in a lucite phantom using the epithermal beam is under development. Preliminary data indicate that this approach can be used to detect differences in the relative biological effectiveness of the beam. The rat 9L gliosarcoma cell survival data was converted to photon-equivalent doses using the same factors assumed in the clinical studies. The results superimposed on the survival curve derived from irradiation with Cs-137 photons indicating the potential utility of this model system. (author)

  2. Prediction of iodine-131 biokinetics and radiation doses from therapy on the basis of tracer studies: an important question for therapy planning in nuclear medicine.

    Science.gov (United States)

    Willegaignon, José; Pelissoni, Rogério A; Lima, Beatriz C G D; Sapienza, Marcelo T; Coura-Filho, George B; Buchpiguel, Carlos A

    2016-05-01

    This study aimed to present a comparison of iodine-131 (I) biokinetics and radiation doses to red-marrow (rm) and whole-body (wb), following the administration of tracer and therapeutic activities, as a means of confirming whether I clearance and radiation doses for therapy procedures can be predicted by tracer activities. Eleven differentiated thyroid cancer patients were followed after receiving tracer and therapeutic I activity. Whole-body I clearance was estimated using radiation detectors and OLINDA/EXM software was used to calculate radiation doses to rm and wb. Tracer I activity of 86 (±14) MBq and therapeutic activity of 8.04 (±1.18) GBq were administered to patients, thereby producing an average wb I effective half-time and residence time of, respectively, 13.51 (±4.05) and 23.13 (±5.98) h for tracer activities and 13.32 (±3.38) and 19.63 (±4.77) h for therapy. Radiation doses to rm and wb were, respectively, 0.0467 (±0.0208) and 0.0589 (±0.0207) mGy/MBq in tracer studies and 0.0396 (±0.0169) and 0.0500 (±0.0163) mGy/MBq in therapy. Although the differences were not considered statistically significant between averages, those between the values of effective half-times (P=0.906), residence times (P=0.145), and radiation doses to rm (P=0.393) and to wb (P=0.272), from tracer and therapy procedures, large differences of up to 80% in wb I clearance, and up to 50% in radiation doses were observed when patients were analyzed individually, thus impacting on the total amount of I activity calculated to be safe for application in individual therapy. I biokinetics and radiation doses to rm and wb in therapy procedures are well predicted by diagnostic activities when average values of a group of patients are compared. Nonetheless, when patients are analyzed individually, significant differences may be encountered, thus implying that nuclear medicine therapy-planning requires due consideration of changes in individual patient-body status from

  3. Antiproton Cancer Therapy

    DEFF Research Database (Denmark)

    Bassler, Niels

    An essential part in cancer radiotherapy, is to direct a sufficiently high dose towards the tumour, without damaging the surrounding tissue. Different techniques such as intensity modulated radiation therapy and proton therapy have been developed, in order to reduce the dose to the normal tissue...

  4. Early and late effects of local high dose radiotherapy of the brain on memory and attention

    International Nuclear Information System (INIS)

    Duchstein, S.; Gademann, G.; Peters, B.

    2003-01-01

    Early and Late Effects of Local High Dose Radiotherapy of the Brain on Memory and Attention Background: Stereotactic radiotherapy of benign tumors of the base of skull shows excellent tumor control and long survival. Aim is to study the impact of high dose radiation therapy on functions of memory and attention over time. Patients and Methods: 21 patients (age 42 ± 11 years) with tumors of the base of skull (meningiomas, pituitary gland adenomas) were treated by fractionated stereotactic radiotherapy (mean total dose 56,6 Gy/1,8 Gy). Comprehensive neuropsychological tests and MRI brain scans were performed before, 3, 9 and 21 months after therapy. 14 healthy volunteers were tested in parallel at baseline. In the follow-ups patients were their own controls. Results: In pretreatment tests there were significantly worse test results in comparison to the control group in ten of 32 tests. In postradiation tests only few changes were found in the early-delayed period and not much difference was seen in comparison to the baseline tests. In MRI scans tumor recurrences or radiation induced changes were not found. Conclusion: Radiation with high local doses in target volume extremely close to sensitive brain structures like temporal lobes did not induce significant decline of cognitive functions. (orig.) [de

  5. Clinical, patient-related, and economic outcomes of home-based high-dose hemodialysis versus conventional in-center hemodialysis

    Directory of Open Access Journals (Sweden)

    Mitsides N

    2016-07-01

    Full Text Available Nicos Mitsides,1,2 Sandip Mitra,1,2 Tom Cornelis3 1Department of Renal Medicine, Manchester Royal Infirmary, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Center, Manchester, 2National Institute for Healthcare Research Devices for Dignity Healthcare Co-operative, Sheffield, UK; 3Department of Nephrology, Jessa Hospital, Hasselt, Belgium Abstract: Despite technological advances in renal replacement therapy, the preservation of health and quality of life for individuals on dialysis still remains a challenge. The high morbidity and mortality in dialysis warrant further research and insight into the clinical domains of the technique and practice of this therapy. In the last 20 years, the focus of development in the field of hemodialysis (HD has centered around adequate removal of urea and other associated toxins. High-dose HD offers an opportunity to improve mortality, morbidity, and quality of life of patients with end-stage kidney disease. However, the uptake of this modality is low, and the risk associated with the therapy is not fully understood. Recent studies have highlighted the evidence base and improved our understanding of this technique of dialysis. This article provides a review of high-dose and home HD, its clinical impact on patient outcome, and the controversies that exist. Keywords: hemodialysis, home dialysis, high dose, outcomes

  6. Treatment of carcinoma of uterine cervix with high-dose-rate intracavitary irradiation using Ralstron

    International Nuclear Information System (INIS)

    Suh, C.O.; Kim, G.E.; Loh, J.J.K.

    1988-01-01

    From May 1979 through December 1981, a total of 530 patients with carcinoma of the uterine cervix were treated with radiation therapy with curative intent. Of the 530 patients, 365 were treated with a high-dose-rate remote-controlled afterloading system (RALS) using a cobalt source, and 165 patients received a low dose rate using a radium source. External pelvic irradiation with a total of 40-50 Gy to the whole pelvis followed by intracavitary radiation (ICR) with a total dose of 30-39 Gy in ten to 13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rate with high-dose-rate ICR by stage was as follows: stage I:82.7% (N = 19) stage II:69.6% (N = 184), and stage III:52.2% (N = 156). The above results were comparable with those with conventional low-dose-rate ICR treatment, and late complications were far less. The application of high-dose-rate ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually none as compared with that of low-dose-rate ICR. Within a given period of time, more patients can be treated with high-dose-rate ICR because of the short treatment time. The authors therefore conclude that high-dose-rate ICR is suitable for a cancer center where a large number of patients are to be treated

  7. Revisiting Low-Dose Total Skin Electron Beam Therapy in Mycosis Fungoides

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Cameron, E-mail: cameronh@stanford.edu [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Young, James; Navi, Daniel [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Riaz, Nadeem [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States); Lingala, Bharathi; Kim, Youn [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Hoppe, Richard [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States)

    2011-11-15

    Purpose: Total skin electron beam therapy (TSEBT) is a highly effective treatment for mycosis fungoides (MF). The standard course consists of 30 to 36 Gy delivered over an 8- to 10-week period. This regimen is time intensive and associated with significant treatment-related toxicities including erythema, desquamation, anhydrosis, alopecia, and xerosis. The aim of this study was to identify a lower dose alternative while retaining a favorable efficacy profile. Methods and Materials: One hundred two MF patients were identified who had been treated with an initial course of low-dose TSEBT (5-<30 Gy) between 1958 and 1995. Patients had a T stage classification of T2 (generalized patch/plaque, n = 51), T3 (tumor, n = 29), and T4 (erythrodermic, n = 22). Those with extracutaneous disease were excluded. Results: Overall response (OR) rates (>50% improvement) were 90% among patients with T2 to T4 disease receiving 5 to <10 Gy (n = 19). In comparison, OR rates between the 10 to <20 Gy and 20 to <30 Gy subgroups were 98% and 97%, respectively. There was no significant difference in median progression free survival (PFS) in T2 and T3 patients when stratified by dose group, and PFS in each was comparable to that of the standard dose. Conclusions: OR rates associated with low-dose TSEBT in the ranges of 10 to <20 Gy and 20 to <30 Gy are comparable to that of the standard dose ({>=} 30 Gy). Efficacy measures including OS, PFS, and RFS are also favorable. Given that the efficacy profile is similar between 10 and <20 Gy and 20 and <30 Gy, the utility of TSEBT within the lower dose range of 10 to <20 Gy merits further investigation, especially in the context of combined modality treatment.

  8. R-hyper-CVAD versus R-CHOP/cytarabine with high-dose therapy and autologous haematopoietic stem cell support in fit patients with mantle cell lymphoma: 20 years of single-center experience.

    Science.gov (United States)

    Widmer, Fabienne; Balabanov, Stefan; Soldini, Davide; Samaras, Panagiotis; Gerber, Bernhard; Manz, Markus G; Goede, Jeroen S

    2018-02-01

    Standard of care for untreated mantle cell lymphoma (MCL) is still debated. At the University Hospital Zurich, advanced MCL in physically fit patients is treated either with rituximab plus cyclophosphamide, doxorubicin, vincristine and prednisone induction followed by consolidating high-dose chemotherapy and autologous stem cell support (R-CHOP/HD-ASCT), or with rituximab plus fractionated cyclophosphamide, vincristine, doxorubicin and dexamethasone alternating with high-dose methotrexate-cytarabine (R-hyper-CVAD/MTX-AraC) without consolidating HD-ASCT upon physicians' and patients' choice. We retrospectively analysed the outcome and therapy tolerance in patients with MCL treated with R-CHOP/HD-ASCT or R-hyper-CVAD/MTX-AraC at the University Hospital Zurich between January 1996 and January 2016. Forty-three patients were included; 29 patients received R-CHOP/HD-ASCT and 14 patients R-hyper-CVAD/MTX-AraC. Mean age at diagnosis was 54.4 years (range 38-68 years). Thirty-five patients (81.4%) completed the entire first-line therapy (n = 24 in the R-CHOP/HD-ASCT group, n = 11 in the R-hyper-CVAD group). Of those, all patients responded and 97% achieved a complete remission (CR). With a mean follow-up of 5.7 years 10-year progression-free survival (PFS) for all patients was 32% and overall survival (OS) was 76%, with no difference between the two therapy groups. Complication-induced hospitalisation rate, haematological toxicity and economic burden were significantly higher in the R-hyper-CVAD therapy group. In contrast, quality of life and global health state were better in the R-hyper-CVAD therapy group. Both first-line therapies showed similar outcome with a median OS longer than 10 years. Due to significantly lower haematological toxicity and lower economic burden, we recommend R-CHOP/HD-ASCT as first-line therapy in fit adult patients with advanced MCL.

  9. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  10. Secondary neutron doses received by patients of different ages during intracranial proton therapy treatments

    International Nuclear Information System (INIS)

    Sayah, R.

    2012-01-01

    Proton therapy is an advanced radiation therapy technique that allows delivering high doses to the tumor while saving the healthy surrounding tissues due to the protons' ballistic properties. However, secondary particles, especially neutrons, are created during protons' nuclear reactions in the beam-line and the treatment room components, as well as inside the patient. Those secondary neutrons lead to unwanted dose deposition to the healthy tissues located at distance from the target, which may increase the secondary cancer risks to the patients, especially the pediatric ones. The aim of this work was to calculate the neutron secondary doses received by patients of different ages treated at the Institut Curie-centre de Protontherapie d'Orsay (ICPO) for intracranial tumors, using a 178 MeV proton beam. The treatments are undertaken at the new ICPO room equipped with an IBA gantry. The treatment room and the beam-line components, as well as the proton source were modeled using the Monte Carlo code MCNPX. The obtained model was then validated by a series of comparisons between model calculations and experimental measurements. The comparisons concerned: a) depth and lateral proton dose distributions in a water phantom, b) neutron spectrometry at one position in the treatment room, c) ambient dose equivalents at different positions in the treatment room and d) secondary absorbed doses inside a physical anthropomorphic phantom. A general good agreement was found between calculations and measurements, thus our model was considered as validated. The University of Florida hybrid voxelized phantoms of different ages were introduced into the MCNPX validated model, and secondary neutron doses were calculated to many of these phantoms' organs. The calculated doses were found to decrease as the organ's distance to the treatment field increases and as the patient's age increases. The secondary doses received by a one year-old patient may be two times higher than the doses

  11. Fast pencil beam dose calculation for proton therapy using a double-Gaussian beam model

    Directory of Open Access Journals (Sweden)

    Joakim eda Silva

    2015-12-01

    Full Text Available The highly conformal dose distributions produced by scanned proton pencil beams are more sensitive to motion and anatomical changes than those produced by conventional radiotherapy. The ability to calculate the dose in real time as it is being delivered would enable, for example, online dose monitoring, and is therefore highly desirable. We have previously described an implementation of a pencil beam algorithm running on graphics processing units (GPUs intended specifically for online dose calculation. Here we present an extension to the dose calculation engine employing a double-Gaussian beam model to better account for the low-dose halo. To the best of our knowledge, it is the first such pencil beam algorithm for proton therapy running on a GPU. We employ two different parametrizations for the halo dose, one describing the distribution of secondary particles from nuclear interactions found in the literature and one relying on directly fitting the model to Monte Carlo simulations of pencil beams in water. Despite the large width of the halo contribution, we show how in either case the second Gaussian can be included whilst prolonging the calculation of the investigated plans by no more than 16%, or the calculation of the most time-consuming energy layers by about 25%. Further, the calculation time is relatively unaffected by the parametrization used, which suggests that these results should hold also for different systems. Finally, since the implementation is based on an algorithm employed by a commercial treatment planning system, it is expected that with adequate tuning, it should be able to reproduce the halo dose from a general beam line with sufficient accuracy.

  12. Occlusion-amblyopia following high dose oral levodopa combined with part time patching

    Directory of Open Access Journals (Sweden)

    Mihir Kothari

    2014-01-01

    Full Text Available Part time occlusion therapy is not reported to cause occlusion (reverse amblyopia. However, when combined with high dose oral levodopa, an increase in the plasticity of the visual cortex can lead to occlusion amblyopia. In this case report, we describe a six year old child who developed occlusion amblyopia following part time patching combined with oral levodopa.

  13. SU-F-J-133: Adaptive Radiation Therapy with a Four-Dimensional Dose Calculation Algorithm That Optimizes Dose Distribution Considering Breathing Motion

    Energy Technology Data Exchange (ETDEWEB)

    Ali, I; Algan, O; Ahmad, S [University of Oklahoma Health Sciences, Oklahoma City, OK (United States); Alsbou, N [University of Central Oklahoma, Edmond, OK (United States)

    2016-06-15

    Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for the stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion management

  14. An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art II

    International Nuclear Information System (INIS)

    Bailat, Claude J.; Buchillier, Thierry; Pachoud, Marc; Moeckli, Raphaeel; Bochud, Francois O.

    2009-01-01

    Purpose: A helical tomotherapy accelerator presents a dosimetric challenge because, to this day, there is no internationally accepted protocol for the determination of the absolute dose. Because of this reality, we investigated the different alternatives for characterizing and measuring the absolute dose of such an accelerator. We tested several dosimetric techniques with various metrological traceabilities as well as using a number of phantoms in static and helical modes. Methods: Firstly, the relationship between the reading of ionization chambers and the absorbed dose is dependent on the beam quality value of the photon beam. For high energy photons, the beam quality is specified by the tissue phantom ratio (TPR 20,10 ) and it is therefore necessary to know the TPR 20,10 to calculate the dose delivered by a given accelerator. This parameter is obtained through the ratio of the absorbed dose at 20 and 10 cm depths in water and was measured in the particular conditions of the tomotherapy accelerator. Afterward, measurements were performed using the ionization chamber (model A1SL) delivered as a reference instrument by the vendor. This chamber is traceable in absorbed dose to water in a Co-60 beam to a water calorimeter of the American metrology institute (NIST). Similarly, in Switzerland, each radiotherapy department is directly traceable to the Swiss metrology institute (METAS) in absorbed dose to water based on a water calorimeter. For our research, this traceability was obtained by using an ionization chamber traceable to METAS (model NE 2611A), which is the secondary standard of our institute. Furthermore, in order to have another fully independent measurement method, we determined the dose using alanine dosimeters provided by and traceable to the British metrology institute (NPL); they are calibrated in absorbed dose to water using a graphite calorimeter. And finally, we wanted to take into account the type of chamber routinely used in clinical practice and

  15. Safety handling manual for high dose rate remote afterloading system

    International Nuclear Information System (INIS)

    1999-01-01

    This manual is mainly for safety handling of 192 Ir-RALS (remote afterloading system) of high dose rate and followings were presented: Procedure and document format for the RALS therapy and for handling of its radiation source with the purpose of prevention of human errors and unexpected accidents, Procedure for preventing errors occurring in the treatment schedule and operation, and Procedure and format necessary for newly introducing the system into a facility. Consistency was intended in the description with the quality assurance guideline for therapy with small sealed radiation sources made by JASTRO (Japan Society for Therapeutic Radiology and Oncology). Use of the old type 60 Co-RALS was pointed out to be a serious problem remained and its safety handling procedure was also presented. (K.H.)

  16. [Comparison of dose calculation algorithms in stereotactic radiation therapy in lung].

    Science.gov (United States)

    Tomiyama, Yuki; Araki, Fujio; Kanetake, Nagisa; Shimohigashi, Yoshinobu; Tominaga, Hirofumi; Sakata, Jyunichi; Oono, Takeshi; Kouno, Tomohiro; Hioki, Kazunari

    2013-06-01

    Dose calculation algorithms in radiation treatment planning systems (RTPSs) play a crucial role in stereotactic body radiation therapy (SBRT) in the lung with heterogeneous media. This study investigated the performance and accuracy of dose calculation for three algorithms: analytical anisotropic algorithm (AAA), pencil beam convolution (PBC) and Acuros XB (AXB) in Eclipse (Varian Medical Systems), by comparison against the Voxel Monte Carlo algorithm (VMC) in iPlan (BrainLab). The dose calculations were performed with clinical lung treatments under identical planning conditions, and the dose distributions and the dose volume histogram (DVH) were compared among algorithms. AAA underestimated the dose in the planning target volume (PTV) compared to VMC and AXB in most clinical plans. In contrast, PBC overestimated the PTV dose. AXB tended to slightly overestimate the PTV dose compared to VMC but the discrepancy was within 3%. The discrepancy in the PTV dose between VMC and AXB appears to be due to differences in physical material assignments, material voxelization methods, and an energy cut-off for electron interactions. The dose distributions in lung treatments varied significantly according to the calculation accuracy of the algorithms. VMC and AXB are better algorithms than AAA for SBRT.

  17. Can we avoid high levels of dose escalation for high-risk prostate cancer in the setting of androgen deprivation?

    Science.gov (United States)

    Shakespeare, Thomas P; Wilcox, Shea W; Aherne, Noel J

    2016-01-01

    Both dose-escalated external beam radiotherapy (DE-EBRT) and androgen deprivation therapy (ADT) improve outcomes in patients with high-risk prostate cancer. However, there is little evidence specifically evaluating DE-EBRT for patients with high-risk prostate cancer receiving ADT, particularly for EBRT doses >74 Gy. We aimed to determine whether DE-EBRT >74 Gy improves outcomes for patients with high-risk prostate cancer receiving long-term ADT. Patients with high-risk prostate cancer were treated on an institutional protocol prescribing 3-6 months neoadjuvant ADT and DE-EBRT, followed by 2 years of adjuvant ADT. Between 2006 and 2012, EBRT doses were escalated from 74 Gy to 76 Gy and then to 78 Gy. We interrogated our electronic medical record to identify these patients and analyzed our results by comparing dose levels. In all, 479 patients were treated with a 68-month median follow-up. The 5-year biochemical disease-free survivals for the 74 Gy, 76 Gy, and 78 Gy groups were 87.8%, 86.9%, and 91.6%, respectively. The metastasis-free survivals were 95.5%, 94.5%, and 93.9%, respectively, and the prostate cancer-specific survivals were 100%, 94.4%, and 98.1%, respectively. Dose escalation had no impact on any outcome in either univariate or multivariate analysis. There was no benefit of DE-EBRT >74 Gy in our cohort of high-risk prostate patients treated with long-term ADT. As dose escalation has higher risks of radiotherapy-induced toxicity, it may be feasible to omit dose escalation beyond 74 Gy in this group of patients. Randomized studies evaluating dose escalation for high-risk patients receiving ADT should be considered.

  18. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier, David, E-mail: d-pasquier@o-lambret.fr [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Centre Galilee, Clinique de la Louviere, Lille (France); Cavillon, Fabrice [Universite Lille Nord de France, Lille (France); Faculte Libre de Medecine, Lille (France); Lacornerie, Thomas [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France); Touzeau, Claire [Centre Galilee, Clinique de la Louviere, Lille (France); Tresch, Emmanuelle [Unite de Methodologie et Biostatistique, Centre O. Lambret, Lille (France); Lartigau, Eric [Departement Universitaire de Radiotherapie, Centre O. Lambret, Lille (France); Universite Lille Nord de France, Lille (France)

    2013-02-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  19. Monte Carlo calculations of lung dose in ORNL phantom for boron neutron capture therapy

    International Nuclear Information System (INIS)

    Krstic, D.; Markovic, V.M.; Jovanovic, Z.; Milenkovic, B.; Nikezic, D.; Atanackovic, J.

    2014-01-01

    Monte Carlo simulations were performed to evaluate dose for possible treatment of cancers by boron neutron capture therapy (BNCT). The computational model of male Oak Ridge National Laboratory (ORNL) phantom was used to simulate tumours in the lung. Calculations have been performed by means of the MCNP5/X code. In this simulation, two opposite neutron beams were considered, in order to obtain uniform neutron flux distribution inside the lung. The obtained results indicate that the lung cancer could be treated by BNCT under the assumptions of calculations. The difference in evaluated dose in cancer and normal lung tissue suggests that BNCT could be applied for the treatment of cancers. The difference in exposure of cancer and healthy tissue can be observed, so the healthy tissue can be spared from damage. An absorbed dose ratio of metastatic tissue-to-the healthy tissue was ∼5. Absorbed dose to all other organs was low when compared with the lung dose. Absorbed dose depth distribution shows that BNC therapy can be very useful in the treatments for tumour. The ratio of the tumour absorbed dose and irradiated healthy tissue absorbed dose was also ∼5. It was seen that an elliptical neutron field was better irradiation choice. (authors)

  20. Comparison of high dose rate (HDR) and low dose rate (LDR) brachytherapy in the treatment of stage IIIB cervix cancer with radiation therapy alone. The preliminary results

    International Nuclear Information System (INIS)

    Trippe, Nivaldo; Novaes, P.E.; Ferrigno, R.; Pellizzon, A.C.; Salvajoli, J.V.; Fogaroli, R.C.; Maia, M.A.C.; Baraldi, H.E.

    1996-01-01

    Purpose/Objective: To compare the results between HDR and LDR brachytherapy in the treatment of stage IIIB cervix cancer with radiation therapy alone through a prospective and randomized trial. Materials and Methods: From September 1992 to December 1993, 65 patients with stage IIIB cervical cancer were randomized to one of the following treatment schedule according to the brachytherapy used to complement the dose of external beam radiotherapy (EBRT): 1 - High dose rate (HDR) - 36 patients - 4 weekly insertions of 6,0 Gy at point A 2 - Low dose rate (LDR) - 29 patients - 2 insertions two weeks apart of 17,5 Gy at point A The External Beam radiotherapy was performed through a Linac 4MV, in box arrangement for whole pelvis and in AP-PA fields for parametrial complementation of dose. The dose at the whole pelvis was 45 Gy in 25 fractions of 1,8 Gy and the parametrial dose was 16 Gy. The brachytherapy was realized with Fletcher colpostats and intrauterine tandem, in both arms. The HDR brachytherapy was realized through a Micro-Selectron device, working with Iridium-192 with initial activity of 10 Ci and started ten days after the beginning of EBRT. The total treatment time was shortened in two weeks for this group. The LDR brachytherapy started only after the end of EBRT. Results: With the minimum follow up of 24 months and medium of 31 months, the disease free survival was 50% among the 36 patients in HDR group and 47,8% among the 29 patients in LDR group. Local failures occurred in 50% and 52,8% respectively. Grade I and II complications were restricted to rectites and cistites and the incidence of them was 8,3% for HDR group and 13% for LDR group. Until the time of evaluation there were no grade III complications in any group. Conclusions: Although the number of patients is small and the time of follow up still short, these preliminary results suggest that the HDR brachytherapy has an equivalent efficiency in local control as the LDR in the treatment of stage IIIB

  1. A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial

    International Nuclear Information System (INIS)

    Showalter, Shayna L.; Petroni, Gina; Trifiletti, Daniel M.; Libby, Bruce; Schroen, Anneke T.; Brenin, David R.; Dalal, Parchayi; Smolkin, Mark; Reardon, Kelli A.; Showalter, Timothy N.

    2016-01-01

    Purpose: Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. Methods and Materials: A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Results: Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. Conclusions: CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial.

  2. A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Showalter, Shayna L., E-mail: snl2t@virginia.edu [Division of Surgical Oncology, Department of Surgery, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Petroni, Gina [Division of Translation Research and Applied Statistics, Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Trifiletti, Daniel M.; Libby, Bruce [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Schroen, Anneke T.; Brenin, David R. [Division of Surgical Oncology, Department of Surgery, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Dalal, Parchayi [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Smolkin, Mark [Division of Translation Research and Applied Statistics, Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Reardon, Kelli A.; Showalter, Timothy N. [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States)

    2016-09-01

    Purpose: Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. Methods and Materials: A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Results: Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. Conclusions: CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial.

  3. Improved Outcome of Enteric Peritonitis in Peritoneal Dialysis Patients Aged 50 Years and Older with Temporary Discontinuation of Peritoneal Dialysis and Intravenous Meropenem.

    Science.gov (United States)

    Abrahams, Alferso C; Rüger, Wim; Ter Wee, Pieter M; van Ittersum, Frans J; Boer, Walther H

    2017-01-01

    ♦ BACKGROUND: Peritonitis is a major cause of morbidity, mortality, and technique failure in peritoneal dialysis (PD) patients, especially when caused by enteric microorganisms (EM). We have implemented a treatment protocol specifically aimed at improving the outcome in EM peritonitis. The adapted protocol was applied in all PD patients 50 years and older presenting with peritonitis who were considered to be at risk of EM peritonitis and involves 3 interventions: 1) temporary discontinuation of PD without removing the catheter (peritoneal rest), 2) intravenous meropenem, and 3) meropenem intracatheter as lock (Mero-PerRest protocol). ♦ METHODS: In this observational study, we compared the outcome of 203 peritonitis episodes in 71 patients treated with the Mero-PerRest protocol, with 217 episodes in 104 patients treated with a more traditional intraperitoneal gentamicin-rifampicin-based regimen. ♦ RESULTS: In EM peritonitis episodes, the Mero-PerRest protocol resulted in a higher primary cure rate (90.0% vs 65.3%, adjusted odds ratio [OR] 4.54 [95% confidence interval (CI) 1.46 - 14.15]) and better technique survival (90.0% vs 69.4%, adjusted OR 3.41 [95% CI 1.07 - 10.87]). This effect was most distinct in patients with polymicrobial EM peritonitis (cure rate 87.5% vs 34.8%, p = 0.0003). Interestingly, primary cure rate (95.6% vs 84.7%, adjusted OR 3.92 [95% CI 1.37 - 11.19]) and technique survival (95.6% vs 85.6%, adjusted OR 3.60 [95% CI 1.25 - 10.32]) were also excellent in non-EM peritonitis episodes. Patient survival did not differ significantly. ♦ CONCLUSION: The poor outcome of peritonitis caused by EM in PD patients aged 50 years and older could be improved by applying a treatment protocol involving temporary discontinuation of PD without catheter removal and intravenous and intracatheter meropenem. Copyright © 2017 International Society for Peritoneal Dialysis.

  4. Optimizing Collimator Margins for Isotoxically Dose-Escalated Conformal Radiation Therapy of Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Samantha, E-mail: Samantha.warren@oncology.ox.ac.uk [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom); Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom); Panettieri, Vanessa [William Buckland Radiotherapy Centre, Alfred Hospital, Commercial Road, Melbourne (Australia); Panakis, Niki; Bates, Nicholas [Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom); Lester, Jason F. [Velindre Cancer Centre, Velindre Road, Whitchurch, Cardiff (United Kingdom); Jain, Pooja [Clatterbridge Cancer Centre, Clatterbridge Road, Wirral (United Kingdom); Landau, David B. [Department of Radiotherapy, Guy' s and St. Thomas' NHS Foundation Trust, London (United Kingdom); Nahum, Alan E.; Mayles, W. Philip M. [Clatterbridge Cancer Centre, Clatterbridge Road, Wirral (United Kingdom); Fenwick, John D. [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom); Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom)

    2014-04-01

    Purpose: Isotoxic dose escalation schedules such as IDEAL-CRT [isotoxic dose escalation and acceleration in lung cancer chemoradiation therapy] (ISRCTN12155469) individualize doses prescribed to lung tumors, generating a fixed modeled risk of radiation pneumonitis. Because the beam penumbra is broadened in lung, the choice of collimator margin is an important element of the optimization of isotoxic conformal radiation therapy for lung cancer. Methods and Materials: Twelve patients with stage I-III non-small cell lung cancer (NSCLC) were replanned retrospectively using a range of collimator margins. For each plan, the prescribed dose was calculated according to the IDEAL-CRT isotoxic prescription method, and the absolute dose (D{sub 99}) delivered to 99% of the planning target volume (PTV) was determined. Results: Reducing the multileaf collimator margin from the widely used 7 mm to a value of 2 mm produced gains of 2.1 to 15.6 Gy in absolute PTV D{sub 99}, with a mean gain ± 1 standard error of the mean of 6.2 ± 1.1 Gy (2-sided P<.001). Conclusions: For NSCLC patients treated with conformal radiation therapy and an isotoxic dose prescription, absolute doses in the PTV may be increased by using smaller collimator margins, reductions in relative coverage being offset by increases in prescribed dose.

  5. Comprehensive evaluations of cone-beam CT dose in image-guided radiation therapy via GPU-based Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Montanari, Davide; Scolari, Enrica; Silvestri, Chiara; Graves, Yan Jiang; Cervino, Laura [Center for Advanced Radiotherapy Technologies, University of California San Diego, La Jolla, CA 92037-0843 (United States); Yan, Hao; Jiang, Steve B; Jia, Xun [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390-9315 (United States); Rice, Roger [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA 92037-0843 (United States)

    2014-03-07

    Cone beam CT (CBCT) has been widely used for patient setup in image-guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are (1) to commission a graphics processing unit (GPU)-based Monte Carlo (MC) dose calculation package gCTD for Varian On-Board Imaging (OBI) system and test the calculation accuracy, and (2) to quantitatively evaluate CBCT dose from the OBI system in typical IGRT scan protocols. We first conducted dose measurements in a water phantom. X-ray source model parameters used in gCTD are obtained through a commissioning process. gCTD accuracy is demonstrated by comparing calculations with measurements in water and in CTDI phantoms. Twenty-five brain cancer patients are used to study dose in a standard-dose head protocol, and 25 prostate cancer patients are used to study dose in pelvis protocol and pelvis spotlight protocol. Mean dose to each organ is calculated. Mean dose to 2% voxels that have the highest dose is also computed to quantify the maximum dose. It is found that the mean dose value to an organ varies largely among patients. Moreover, dose distribution is highly non-homogeneous inside an organ. The maximum dose is found to be 1–3 times higher than the mean dose depending on the organ, and is up to eight times higher for the entire body due to the very high dose region in bony structures. High computational efficiency has also been observed in our studies, such that MC dose calculation time is less than 5 min for a typical case. (paper)

  6. A dose escalation study of concurrent chemoradiation therapy with nedaplatin for cervical cancer

    International Nuclear Information System (INIS)

    Hatae, Masayuki; Takahashi, Takeshi; Kodama, Shoji

    2005-01-01

    Doses of nedaplatin (CDGP) were established for concurrent chemoradiation therapy (CCRT) for cervical cancer, and a collaborative dose escalation study involving 8 hospitals was conducted to investigate the safety and efficacy of this therapy. Radiotherapy was performed according to the standard treatment described in the Regulations of Cervical Carcinoma Treatment. CDGP at 80 mg/m 2 as Level 1 or at 90 mg/m 2 as Level 2 was administered on Days 1 and 29 of treatment. Dose-limiting toxicity (DLT) was observed in 1 of 6 patients receiving 80 mg/m 2 of CDGP and in all 2 patients receiving 90 mg/m 2 of CDGP; therefore, Level 2 was regarded as the maximum tolerated dose (MTD), and Level 1 as the recommended dose. DLT signs consisted of delayed improvement in the leukocyte count in 2 patients and anorexia in 1 patient, suggesting that delayed improvement in the leukocyte count is the main DLT of this combination therapy. The main side effects were digestive disorders such as nausea and anorexia and bone marrow suppression, such as leukopenia, neutropenia, and thrombopenia. Side effects in the Level 1 group were more mild than in the Level 2 group. The efficacy was partial response (PR) or better in all patients. The complete response (CR) rates were 60% (6/10) in the Level 1 group and 50% (1/2) in the Level 2 group; there was no marked difference between the two groups. These results suggest that CCRT involving administration CDGP at 80 mg/m 2 on Days 1 and 29 is safe and effective. (author)

  7. Influence of pre-hydration and pharmacogenetics on plasma methotrexate concentration and renal dysfunction following high-dose methotrexate therapy.

    Science.gov (United States)

    Yanagimachi, Masakatsu; Goto, Hiroaki; Kaneko, Tetsuji; Naruto, Takuya; Sasaki, Koji; Takeuchi, Masanobu; Tanoshima, Reo; Kato, Hiromi; Yokosuka, Tomoko; Kajiwara, Ryosuke; Fujii, Hisaki; Tanaka, Fumiko; Goto, Shoko; Takahashi, Hiroyuki; Mori, Masaaki; Kai, Sumio; Yokota, Shumpei

    2013-12-01

    High-dose methotrexate therapy (HD-MTX) has been well established for the treatment of childhood acute lymphoblastic leukemia (ALL). The aims of this study were to investigate whether clinical and pharmacogenetic factors influence plasma MTX concentration and renal dysfunction in patients treated with HD-MTX. In a total of 127 courses of HD-MTX in 51 patients with childhood ALL, influence of clinical and pharmacogenetic factors on plasma MTX concentration and HD-MTX-related renal dysfunction was evaluated. Clinical factors included age, gender, duration of HD-MTX continuous-infusion and duration of pre-hydration before HD-MTX. Pharmacogenetic factors included 5 gene polymorphisms within the MTX pathway genes, namely, SLC19A1, MTHFR, ABCC2 and ABCG2. Short duration of pre-hydration before HD-MTX is the most important risk factor for prolonged high MTX concentration (p < 0.001, OR 6.40, 95 % CI 2.39-17.16) and renal dysfunction (p = 0.013, OR 3.15, 95 % CI 1.27-7.80). The T allele at MTHFR C677T was the risk factor for prolonged high MTX concentration (p = 0.009, OR 5.54, 95 % CI 1.54-19.85), but not for renal dysfunction. We found the influence of MTHFR C677T polymorphism on prolonged high MTX concentration. We reconfirmed the importance of adequate pre-hydration before HD-MTX to prevent prolonged high MTX concentration and MTX-related renal dysfunction.

  8. In Vitro Comparison of Ertapenem, Meropenem, and Imipenem against Isolates of Rapidly Growing Mycobacteria and Nocardia by Use of Broth Microdilution and Etest.

    Science.gov (United States)

    Brown-Elliott, Barbara A; Killingley, Jessica; Vasireddy, Sruthi; Bridge, Linda; Wallace, Richard J

    2016-06-01

    We compared the activities of the carbapenems ertapenem, meropenem, and imipenem against 180 isolates of rapidly growing mycobacteria (RGM) and 170 isolates of Nocardia using the Clinical and Laboratory Standards Institute (CLSI) guidelines. A subset of isolates was tested using the Etest. The rate of susceptibility to ertapenem and meropenem was limited and less than that to imipenem for the RGM. Analysis of major and minor discrepancies revealed that >90% of the isolates of Nocardia had higher MICs by the broth microdilution method than by Etest, in contrast to the lower broth microdilution MICs seen for >80% of the RGM. Imipenem remains the most active carbapenem against RGM, including Mycobacterium abscessus subsp. abscessus For Nocardia, imipenem was significantly more active only against Nocardia farcinica Although there may be utility in testing the activities of the newer carbapenems against Nocardia, their activities against the RGM should not be routinely tested. Testing by Etest is not recommended by the CLSI. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  9. Extension of the biological effective dose to the MIRD schema and possible implications in radionuclide therapy dosimetry

    International Nuclear Information System (INIS)

    Baechler, Sebastien; Hobbs, Robert F.; Prideaux, Andrew R.; Wahl, Richard L.; Sgouros, George

    2008-01-01

    In dosimetry-based treatment planning protocols, patients with rapid clearance of the radiopharmaceutical require a larger amount of initial activity than those with slow clearance to match the absorbed dose to the critical organ. As a result, the dose-rate to the critical organ is higher in patients with rapid clearance and may cause unexpected toxicity compared to patients with slow clearance. In order to account for the biological impact of different dose-rates, radiobiological modeling is beginning to be applied to the analysis of radionuclide therapy patient data. To date, the formalism used for these analyses is based on kinetics derived from activity in a single organ, the target. This does not include the influence of other source organs to the dose and dose-rate to the target organ. As a result, only self-dose irradiation in the target organ contributes to the dose-rate. In this work, the biological effective dose (BED) formalism has been extended to include the effect of multiple source organ contributions to the net dose-rate in a target organ. The generalized BED derivation has been based on the Medical Internal Radionuclide Dose Committee (MIRD) schema assuming multiple source organs following exponential effective clearance of the radionuclide. A BED-based approach to determine the largest safe dose to critical organs has also been developed. The extended BED formalism is applied to red marrow dosimetry, as well as kidney dosimetry considering the cortex and the medulla separately, since both those organs are commonly dose limiting in radionuclide therapy. The analysis shows that because the red marrow is an early responding tissue (high α/β), it is less susceptible to unexpected toxicity arising from rapid clearance of high levels of administered activity in the marrow or in the remainder of the body. In kidney dosimetry, the study demonstrates a complex interplay between clearance of activity in the cortex and the medulla, as well as the initial

  10. Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xudong; Charlton, Michael A.; Esquivel, Carlos; Eng, Tony Y.; Li, Ying; Papanikolaou, Nikos [University of Texas Health Science Center, San Antonio, Texas 78229 (United States)

    2013-09-15

    Purpose: To evaluate the neutron and photon dose equivalent rates at the treatment vault entrance (H{sub n,D} and H{sub G}), and to study the secondary radiation to the patient in GRID therapy. The radiation activation on the grid was studied.Methods: A Varian Clinac 23EX accelerator was working at 18 MV mode with a grid manufactured by .decimal, Inc. The H{sub n,D} and H{sub G} were measured using an Andersson–Braun neutron REM meter, and a Geiger Müller counter. The radiation activation on the grid was measured after the irradiation with an ion chamber γ-ray survey meter. The secondary radiation dose equivalent to patient was evaluated by etched track detectors and OSL detectors on a RANDO{sup ®} phantom.Results: Within the measurement uncertainty, there is no significant difference between the H{sub n,D} and H{sub G} with and without a grid. However, the neutron dose equivalent to the patient with the grid is, on average, 35.3% lower than that without the grid when using the same field size and the same amount of monitor unit. The photon dose equivalent to the patient with the grid is, on average, 44.9% lower. The measured average half-life of the radiation activation in the grid is 12.0 (±0.9) min. The activation can be categorized into a fast decay component and a slow decay component with half-lives of 3.4 (±1.6) min and 15.3 (±4.0) min, respectively. There was no detectable radioactive contamination found on the surface of the grid through a wipe test.Conclusions: This work indicates that there is no significant change of the H{sub n,D} and H{sub G} in GRID therapy, compared with a conventional external beam therapy. However, the neutron and scattered photon dose equivalent to the patient decrease dramatically with the grid and can be clinical irrelevant. Meanwhile, the users of a grid should be aware of the possible high dose to the radiation worker from the radiation activation on the surface of the grid. A delay in handling the grid after the beam

  11. Influence of high-dose lipid lowering treatment compared to low-dose lipid lowering treatment on plaque composition assessed by intravascular ultrasound virtual histology in patients with ST-segment elevation acute myocardial infarction

    DEFF Research Database (Denmark)

    Egede, Rasmus; Jensen, Lisette Okkels; Hansen, Henrik Steen

    2013-01-01

    Aims: The aim of this study was to evaluate the effect of low-dose versus high-dose rosuvastatin therapy on the necrotic core content in coronary plaques of angiographic non-significant lesions as assessed by intravascular ultrasound - virtual histology. Methods and results: Eighty-seven statin...

  12. Evaluation of dose delivered to critical organs during pituitary radiation therapy

    International Nuclear Information System (INIS)

    Awoda, Marwa Elrashied Mohammed

    2017-12-01

    The selection of an appropriate energy in radiation therapy for tumor and the delivery adequate dose to the tumors to be treated, is very important during the radiation treatment planning. Also the dose received to critical organs surrounding the tumor has be considered. In addition, validation of treatment plan quality is important, so the purpose of this study was to evaluate the effect of teletherapy cobalt and 6MV linac energies on dose distribution for the pituitary gland tumors and dose delivered to critical organs surrounding the tumor. 10 patients with pituitary adenocarcinomas were selected. For treatment plans with three field technique, verdes and two lateral fields, were used. For the therapeutic area, five organs left and right eye lens left and right optic never and chasms and brain stem, were considered as Organ at risk (OARS). Several physical indices for for planning target volume (PTV) and the organs at risk 9 (OARS) as means dose (MD). 95%, dose (D950), 5% dose (D5) and normal tissue dose (NTID), were calculated, and the homogeneity index and conformity index were also two other evaluation parameters have been taken into account. The comparative evaluation was based on dose volume histogram ( DVH) analysis for both energies plans. After performing the treatment planning with two different energies the dose received to critical organs and dose distribution in PTV were studied. Results showed that the difference between the integral dose received to OARs with Co-60 and 6-MV linac respectively, 2.16±1.48, 1.85±1.55 for Lt eye lens. 3.01±2.52, 1.89±2.09 for Rt eye lens, 18.5±10.97, 19.43±10.65 for Lt optic nerve and chasms, 15.86±11.30, 17.44±15.73 for Rt optic nerve and chasms and 24.03±13.68, 23.77±16.64 for Brain stem case showed higher integral dose for linac than Co-60 than due to using the 6-MV energy as an open field with no beam modifiers such MLCs or shielding blocks. Eventually, it found that using of 6-MV linac provides better

  13. SU-G-BRA-12: Development of An Intra-Fractional Motion Tracking and Dose Reconstruction System for Adaptive Stereotactic Body Radiation Therapy in High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rezaeian, N Hassan; Chi, Y; Tian, Z; Jiang, S; Hannan, R; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: A clinical trial on stereotactic body radiation therapy (SBRT) for high-risk prostate cancer is undergoing at our institution. In addition to escalating dose to the prostate, we have increased dose to intra-prostatic lesions. Intra-fractional prostate motion deteriorates well planned radiation dose, especially for the small intra-prostatic lesions. To solve this problem, we have developed a motion tracking and 4D dose-reconstruction system to facilitate adaptive re-planning. Methods: Patients in the clinical trial were treated with VMAT using four arcs and 10 FFF beam. KV triggered x-ray projections were taken every 3 sec during delivery to acquire 2D projections of 3D anatomy at the direction orthogonal to the therapeutic beam. Each patient had three implanted prostate markers. Our developed system first determined 2D projection locations of these markers and then 3D prostate translation and rotation via 2D/3D registration of the markers. Using delivery log files, our GPU-based Monte Carlo tool (goMC) reconstructed dose corresponding to each triggered image. The calculated 4D dose distributions were further aggregated to yield the delivered dose. Results: We first tested each module in our system. MC dose engine were commissioned to our treatment planning system with dose difference of <0.5%. For motion tracking, 1789 kV projections from 7 patients were acquired. The 2D marker location error was <1 mm. For 3D motion tracking, root mean square (RMS) errors along LR, AP, and CC directions were 0.26mm, 0.36mm, and 0.01mm respectively in simulation studies and 1.99mm, 1.37mm, and 0.22mm in phantom studies. We also tested the entire system workflow. Our system was able to reconstruct delivered dose. Conclusion: We have developed a functional intra-fractional motion tracking and 4D dose re-construction system to support our clinical trial on adaptive high-risk prostate cancer SBRT. Comprehensive evaluations have shown the capability and accuracy of our system.

  14. Endocrine function following high dose proton therapy for tumors of the upper clivus

    Energy Technology Data Exchange (ETDEWEB)

    Slater, J.D.; Austin-Seymour, M.; Munzenrider, J.; Birnbaum, S.; Carroll, R.; Klibanski, A.; Riskind, P.; Urie, M.; Verhey, L.; Goitein, M.

    1988-09-01

    The endocrine status of patients receiving proton radiation for tumors of the upper clivus was reviewed to evaluate the effect of high dose treatment on the pituitary gland. The fourteen patients had chordomas or low grade chondrosarcomas and were all treated by the same techniques. The median tumor dose was 69.7 Cobalt Gray Equivalent (CGE) with a range from 66.6 to 74.4 CGE. (CGE is used because modulated protons have an RBE of 1.1 compared to 60Co). The daily fraction size was 1.8-2.1 CGE. The median follow-up time is 48 months, ranging from 30 to 68 months. All treatments were planned using a computerized multi-dimensional system with the position of the pituitary outlined on the planning CT scan. Review of the dose distribution indicated that the dose to the pituitary ranged from 60.5 to 72.3 CGE, with a median of 67.6 CGE. One female patient had decreased thyroid and gonadotropin function at the time of diagnosis and has been on hormone replacement since that time. The other three females were all pre-menopausal at the time of radiotherapy. At this time four patients (3 males and 1 female) have developed endocrine abnormalities 14 to 45 months after irradiation. All four had evidence of hypothyroidism and two have also developed corticotropin deficiency. The three males had decreased testosterone levels; the female patient developed amenorrhea and hyperprolactinemia. All four are asymptomatic with ongoing hormone replacement.

  15. Endocrine function following high dose proton therapy for tumors of the upper clivus

    International Nuclear Information System (INIS)

    Slater, J.D.; Austin-Seymour, M.; Munzenrider, J.

    1988-01-01

    The endocrine status of patients receiving proton radiation for tumors of the upper clivus was reviewed to evaluate the effect of high dose treatment on the pituitary gland. The fourteen patients had chordomas or low grade chondrosarcomas and were all treated by the same techniques. The median tumor dose was 69.7 Cobalt Gray Equivalent (CGE) with a range from 66.6 to 74.4 CGE. (CGE is used because modulated protons have an RBE of 1.1 compared to 60Co). The daily fraction size was 1.8-2.1 CGE. The median follow-up time is 48 months, ranging from 30 to 68 months. All treatments were planned using a computerized multi-dimensional system with the position of the pituitary outlined on the planning CT scan. Review of the dose distribution indicated that the dose to the pituitary ranged from 60.5 to 72.3 CGE, with a median of 67.6 CGE. One female patient had decreased thyroid and gonadotropin function at the time of diagnosis and has been on hormone replacement since that time. The other three females were all pre-menopausal at the time of radiotherapy. At this time four patients (3 males and 1 female) have developed endocrine abnormalities 14 to 45 months after irradiation. All four had evidence of hypothyroidism and two have also developed corticotropin deficiency. The three males had decreased testosterone levels; the female patient developed amenorrhea and hyperprolactinemia. All four are asymptomatic with ongoing hormone replacement

  16. Split high‐dose oral levothyroxine treatment as a successful therapy option in myxedema coma

    OpenAIRE

    Charoensri, Suranut; Sriphrapradang, Chutintorn; Nimitphong, Hataikarn

    2017-01-01

    Key Clinical Message High‐dose intravenous thyroxine (T4) is the preferable treatment for myxedema coma. We describe the clinical course of a 69‐year‐old man who presented with myxedema coma and received oral levothyroxine (LT4) therapy (1 mg) in a split dose. This suggests split high‐dose oral LT4 as a therapeutic option in myxedema coma.

  17. Low-dose thiopurine with allopurinol co-therapy overcomes thiopurine intolerance and allows thiopurine continuation in inflammatory bowel disease.

    Science.gov (United States)

    Vasudevan, Abhinav; Beswick, Lauren; Friedman, Antony B; Moltzen, Alicia; Haridy, James; Raghunath, Ajay; Sparrow, Miles; van Langenberg, Daniel

    2018-02-10

    To assess the utility and tolerability of thiopurine-allopurinol co-therapy in inflammatory bowel disease (IBD) patients with intolerance to thiopurine monotherapy. A retrospective observational study assessed cases of thiopurine intolerance then switched to thiopurine allopurinol co-therapy between 2011 and 2015 at two centres. Indications for switch, dosing and subsequent clinical outcomes (including thiopurine persistence) were recorded. Of 767 patients on thiopurines for IBD, 89 (12%) were switched to co-therapy for intolerance. 64/89 (72%) had Crohn's disease, 38 (43%) were males, median age at switch was 40y (range 17-78), median IBD duration 6y (0-29). Median follow-up was 1.9y (0-5). Reasons for switching to co-therapy included fatigue (37%), hepatotoxicity (23%), nausea (23%), arthralgia (10%), headache (12%) and hypersensitivity reaction (4%). Overall, 66 (74%) patients remained on co-therapy until most recent review and achieved a clinical response. High rates of overcoming intolerance (62-100%) occurred with co-therapy for all reasons above, although fatigue was less amenable to switching than non-fatigue indications (62% vs 91%, p = <0.001). Of 34 patients not escalated to biologics with endoscopic data, 15 were in remission (44%) at most recent review. Low-dose thiopurine combined with allopurinol appears safe and effective in overcoming intolerances to thiopurine monotherapy in many cases. Copyright © 2018. Published by Elsevier Ltd.

  18. Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Ito, Kazuto; Saitoh, Jun-ichi; Noda, Shin-ei; Harashima, Koichi; Sakurai, Hideyuki; Nakayama, Yuko; Yamamoto, Takumi; Suzuki, Kazuhiro; Nakano, Takashi; Niibe, Hideo

    2005-01-01

    Purpose: Several investigations have revealed that the α/β ratio for prostate cancer is atypically low, and that hypofractionation or high-dose-rate (HDR) brachytherapy regimens using appropriate radiation doses may be expected to yield tumor control and late sequelae rates that are better or at least as favorable as those achieved with conventional radiation therapy. In this setting, we attempted treating localized prostate cancer patients with HDR brachytherapy combined with hypofractionated external beam radiation therapy (EBRT). The purpose of this study was to evaluate the feasibility of using this approach, with special emphasis on the relationship between the severity of acute genitourinary (GU) toxicity and the urethral dose calculated from the dose-volume histogram (DVH) of HDR brachytherapy. Methods and Materials: Between September 2000 and December 2003, 70 patients with localized prostate cancer were treated by iridium-192 HDR brachytherapy combined with hypofractionated EBRT at the Gunma University Hospital. Hypofractionated EBRT was administered in fraction doses of 3 Gy, three times per week; a total dose of 51 Gy was delivered to the prostate gland and the seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography (TRUS)-guided HDR brachytherapy. The fraction size and the number of fractions in HDR brachytherapy were prospectively changed, whereas the total radiation dose for EBRT was fixed at 51 Gy. The fractionation in HDR brachytherapy was as follows: 5 Gy x 5, 7 Gy x 3, 9 Gy x 2, administered twice per day, although the biologic effective dose (BED) for HDR brachytherapy combined with EBRT, assuming that the α/β ratio is 3, was almost equal to 138 in each fractionation group. The planning target volume was defined as the prostate gland with 5-mm margin all around, and the planning was conducted based on

  19. Measurement of absorbed doses near metal and dental material interfaces irradiated by x- and gamma-ray therapy beams

    International Nuclear Information System (INIS)

    Farahani, M.; Eichmiller, F.C.; McLaughlin, W.L.

    1990-01-01

    Soft-tissue damage adjacent to dental restorations is a deleterious side effect of radiation therapy associated with low-energy electron scatter from dental materials of high electron density. This study was designed to investigate the enhancement of dose to soft tissue (or water) close to high electron-density materials and to measure the detailed lateral and depth-dose profiles in soft-tissue-simulating polymer adjacent to planar interfaces of several higher atomic-number materials: 18-carat gold dental casting alloy; Ag-Hg dental amalgam alloy; Ni-Cr dental casting alloy; and natural human tooth structure. Results indicate that the dose-enhancement in 'tissue' is as great as a factor of 2 on the backscatter side adjacent to gold and a factor of 1.2 adjacent to tooth tissue, but is insignificant on the forward-scatter side because of the predominant effect of attenuation by the high-density, high atomic-number absorbing material. (author)

  20. Pancreatic enzyme replacement therapy in cystic fibrosis: dose, variability and coefficient of fat absorption

    Directory of Open Access Journals (Sweden)

    Joaquim Calvo-Lerma

    Full Text Available Objectives: Pancreatic enzyme replacement therapy (PERT remains a backbone in the nutritional treatment of cystic fibrosis. Currently, there is a lack of an evidence-based tool that allows dose adjustment. To date, no studies have found an association between PERT dose and fat absorption. Therefore, the aim of the study was to assess the influence of both the PERT dose and the variability in this dose on the coefficient of fat absorption (CFA. Methods: This is a retrospective longitudinal study of 16 pediatric patients (192 food records with three consecutive visits to the hospital over a twelve-month period. Dietary fat intake and PERT were assessed via a four-day food record and fat content in stools was determined by means of a three-day stool sample collection. A beta regression model was built to explain the association between the CFA and the interaction between the PERT dose (lipase units [LU]/g dietary fat and the variability in the PERT dose (standard deviation [SD]. Results: The coefficient of fat absorption increased with the PERT dose when the variability in the dose was low. In contrast, even at the highest PERT dose values, the CFA decreased when the variability was high. The confidence interval suggested an association, although the analysis was not statistically significant. Conclusion: The variability in the PERT dose adjustment should be taken into consideration when performing studies on PERT efficiency. A clinical goal should be the maintenance of a constant PERT dose rather than trying to obtain an optimal value.

  1. Pancreatic enzyme replacement therapy in cystic fibrosis: dose, variability and coefficient of fat absorption.

    Science.gov (United States)

    Calvo-Lerma, Joaquim; Martínez-Barona, Sandra; Masip, Etna; Fornés, Victoria; Ribes-Koninckx, Carmen

    2017-10-01

    Pancreatic enzyme replacement therapy (PERT) remains a backbone in the nutritional treatment of cystic fibrosis. Currently, there is a lack of an evidence-based tool that allows dose adjustment. To date, no studies have found an association between PERT dose and fat absorption. Therefore, the aim of the study was to assess the influence of both the PERT dose and the variability in this dose on the coefficient of fat absorption (CFA). This is a retrospective longitudinal study of 16 pediatric patients (192 food records) with three consecutive visits to the hospital over a twelve-month period. Dietary fat intake and PERT were assessed via a four-day food record and fat content in stools was determined by means of a three-day stool sample collection. A beta regression model was built to explain the association between the CFA and the interaction between the PERT dose (lipase units [LU]/g dietary fat) and the variability in the PERT dose (standard deviation [SD]). The coefficient of fat absorption increased with the PERT dose when the variability in the dose was low. In contrast, even at the highest PERT dose values, the CFA decreased when the variability was high. The confidence interval suggested an association, although the analysis was not statistically significant. The variability in the PERT dose adjustment should be taken into consideration when performing studies on PERT efficiency. A clinical goal should be the maintenance of a constant PERT dose rather than trying to obtain an optimal value.

  2. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Moussazadeh, Nelson; Lis, Eric; Katsoulakis, Evangelia; Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily; Bilsky, Mark H.; Yamada, Yoshiya; Laufer, Ilya

    2015-01-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  3. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moussazadeh, Nelson [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katsoulakis, Evangelia [Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, New York (United States); Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bilsky, Mark H. [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Laufer, Ilya, E-mail: lauferi@mskcc.org [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States)

    2015-10-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  4. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  5. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  6. Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma

    Energy Technology Data Exchange (ETDEWEB)

    Karunamuni, Roshan [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Bartsch, Hauke; White, Nathan S. [Department of Radiology, University of California San Diego, La Jolla, California (United States); Moiseenko, Vitali; Carmona, Ruben; Marshall, Deborah C.; Seibert, Tyler M. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); McDonald, Carrie R. [Department of Psychiatry, University of California San Diego, La Jolla, California (United States); Farid, Nikdokht; Krishnan, Anithapriya; Kuperman, Joshua [Department of Radiology, University of California San Diego, La Jolla, California (United States); Mell, Loren [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States); Brewer, James B.; Dale, Anders M. [Department of Radiology, University of California San Diego, La Jolla, California (United States); Hattangadi-Gluth, Jona A., E-mail: jhattangadi@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California (United States)

    2016-02-01

    Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thickness between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.

  7. Long-Term Results of Fixed High-Dose I-131 Treatment for Toxic Nodular Goiter: Higher Euthyroidism Rates in Geriatric Patients

    Directory of Open Access Journals (Sweden)

    Gül Ege Aktaş

    2015-10-01

    Full Text Available Objective: Geriatric patient population has special importance due to particular challenges. In addition to the increase in incidence of toxic nodular goiter (TNG with age, it has a high incidence in the regions of low-medium iodine intake such as in our country. The aim of this study was to evaluate the overall outcome of high fixed dose radioiodine (RAI therapy, and investigate the particular differences in the geriatric patient population. Methods: One hundred and three TNG patients treated with high dose I-131 (370-740 MBq were retrospectively reviewed. The baseline characteristics; age, gender, scintigraphic patterns and thyroid function tests before and after treatment, as well as follow-up, duration of antithyroid drug (ATD medication and achievement of euthyroid or hypothyroid state were evaluated. The patient population was divided into two groups as those=>65 years and those who were younger, in order to assess the effect of age. Results: Treatment success was 90% with single dose RAI therapy. Hyperthyroidism was treated in 7±7, 2 months after RAI administration. At the end of the first year, overall hypothyroidism rate was 30% and euthyroid state was achieved in 70% of patients. Age was found to be the only statistically significant variable effecting outcome. A higher ratio of euthyroidism was achieved in the geriatric patient population. Conclusion: High fixed dose I-131 treatment should be preferred in geriatric TNG patients in order to treat persistent hyperthyroidism rapidly. The result of this study suggests that high fixed dose RAI therapy is a successful modality in treating TNG, and high rates of euthyroidism can be achieved in geriatric patients.

  8. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

    International Nuclear Information System (INIS)

    Martin, Jeffrey M.; Handorf, Elizabeth A.; Price, Robert A.; Cherian, George; Buyyounouski, Mark K.; Chen, David Y.; Kutikov, Alexander; Johnson, Matthew E.; Ma, Chung-Ming Charlie; Horwitz, Eric M.

    2015-01-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality

  9. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Jeffrey M. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Handorf, Elizabeth A. [Department of Biostatistics, Fox Chase Cancer Center, Philadelphia, PA (United States); Price, Robert A.; Cherian, George [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Buyyounouski, Mark K. [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Chen, David Y.; Kutikov, Alexander [Department of Urologic Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Johnson, Matthew E.; Ma, Chung-Ming Charlie [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Horwitz, Eric M., E-mail: eric.horwitz@fccc.edu [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-10-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

  10. Skin dose for head and neck cancer patients treated with intensity-modulated radiation therapy(IMRT)

    Science.gov (United States)

    Fu, Hsiao-Ju; Li, Chi-Wei; Tsai, Wei-Ta; Chang, Chih-Chia; Tsang, Yuk-Wah

    2017-11-01

    The reliability of thermoluminescent dosimeters (ultrathin TLD) and ISP Gafchromic EBT2 film to measure the surface dose in phantom and the skin dose in head-and-neck patients treated with intensity-modulated radiation therapy technique(IMRT) is the research focus. Seven-field treatment plans with prescribed dose of 180 cGy were performed on Eclipse treatment planning system which utilized pencil beam calculation algorithm(PBC). In calibration tests, the variance coefficient of the ultrathin TLDs were within 3%. The points on the calibration curve of the Gafchromic film was within 1% variation. Five measurements were taken on phantom using ultrathin TLD and EBT2 film respectively. The measured mean surface doses between ultrathin TLD or EBT2 film were within 5% deviation. Skin doses of 6 patients were measured for initial 5 fractions and the mean dose per-fraction was calculated. If the extrapolated doses for 30 fractions were below 4000 cGy, the skin reaction grading observed according to Radiation Therapy Oncology Group (RTOG) was either grade 1 or grade 2. If surface dose exceeded 5000 cGy in 32 fractions, then grade 3 skin reactions were observed.

  11. In vivo study on influence of the heterogeneity of tissues in the dose distribution in high energy X ray therapy

    International Nuclear Information System (INIS)

    Aldred, M.A.

    1987-01-01

    Several authors investigated the effect of the heterogeneity of tissue in the dose distribution in a radiation-therapy. Practically all of them carried out ''in vitro'' measurements using a solid body immersed in a water phantom, in order to simulate the inhomogeneity, such as bone, air cavity, etc. In the present work, ''in vivo'' measurements were performed utilizing thermoluminescent dosimeters, whose appropriateness and convenience are well known. Eight patients at Instituto de Radioterapia Oswaldo Cruz were selected, that were under irradiation treatments in their pelvic region. The ratio between body entry radiation dose and the corresponding exit dose, when compared to the same ratio for a homogeneous phantom, gives the influence of the heterogeneity of the tissue the radiation crosses. The results found in those eight patients have shown that ''in vivo'' measurements present a ratio about 8% smaller that in homogeneous phantom case. (author) [pt

  12. Radiation therapy with laser-driven accelerated particle beams: physical dosimetry and spatial dose distribution

    Energy Technology Data Exchange (ETDEWEB)

    Reinhardt, Sabine; Assmann, Walter [Ludwig-Maximilians Universitaet Muenchen (Germany); Kneschaurek, Peter; Wilkens, Jan [MRI, Technische Universitaet Muenchen (Germany)

    2011-07-01

    One of the main goals of the Munich Centre for Advanced Photonics (MAP) is the application of laser driven accelerated (LDA) particle beams for radiation therapy. Due to the unique acceleration process ultrashort particle pulses of high intensity (> 10{sup 7} particles /cm{sup 2}/ns) are generated, which makes online detection an ambitious task. So far, state of the art detection of laser accelerated ion pulses are non-electronic detectors like radiochromic films (RCF), imaging plates (IP) or nuclear track detectors (e.g. CR39). All these kind of detectors are offline detectors requiring several hours of processing time. For this reason they are not qualified for an application in radiation therapy where quantitative real time detection of the beam is an essential prerequisite. Therefore we are investigating pixel detectors for real time monitoring of LDA particle pulses. First tests of commercially available systems with 8-20 MeV protons are presented. For radiobiological experiments second generation Gafchromic films (EBT2) have been calibrated with protons of 12 and 20 MeV for a dose range of 0.3-10 Gy. Dose verification in proton irradiation of subcutaneous tumours in mice was successfully accomplished using these films.

  13. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    International Nuclear Information System (INIS)

    Sandilos, Panagiotis; Baras, Panagiotis; Georgiou, Evangelos; Dardoufas, Konstantinos; Karaiskos, Pantelis; Papagiannis, Panagiotis; Paschalis, Theodoros; Tatsis, Elias; Torrens, Michael; Vlahos, Lampros

    2006-01-01

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an 192 Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications

  14. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    Energy Technology Data Exchange (ETDEWEB)

    Sandilos, Panagiotis [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Baras, Panagiotis [Philips Hellas Medical Systems, 44 Kifissias Ave., Maroussi 151 25, Athens (Greece); Georgiou, Evangelos [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece); Dardoufas, Konstantinos [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Karaiskos, Pantelis [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece)]. E-mail: p.karaiskos@hygeia.gr; Papagiannis, Panagiotis [Physics Department, Nuclear and Particle Physics Section, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Paschalis, Theodoros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Tatsis, Elias [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Torrens, Michael [Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Vlahos, Lampros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece)

    2006-12-20

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an {sup 192}Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications.

  15. Progress in high-dose radiation dosimetry

    International Nuclear Information System (INIS)

    Ettinger, K.V.; Nam, J.W.; McLaughlin, W.L.; Chadwick, K.H.

    1981-01-01

    The last decade has witnessed a deluge of new high-dose dosimetry techniques and expanded applications of methods developed earlier. Many of the principal systems are calibrated by means of calorimetry, although production of heat is not always the final radiation effect of interest. Reference systems also include a number of chemical dose meters: ferrous sulphate, ferrous-cupric sulphate, and ceric sulphate acidic aqueous solutions. Requirements for stable and reliable transfer dose meters have led to further developments of several important high-dose systems: amino acids and saccharides analysed by ESR or lyoluminescence, thermoluminescent materials, radiochromic dyes and plastics, ceric-cerous solutions analysed by potentiometry, and ethanol-chlorobenzene solutions analysed by high-frequency oscillometry. A number of other prospective dose meters are also treated in this review. In addition, an IAEA programme of high-dose standardization and intercomparison for industrial radiation processing is described. (author)

  16. High Dose Cyclophosphamide without Stem Cell Rescue in 207 Patients with Aplastic anemia and other Autoimmune Diseases

    Science.gov (United States)

    DeZern, Amy E.; Petri, Michelle; Drachman, Daniel B.; Kerr, Doug; Hammond, Edward R.; Kowalski, Jeanne; Tsai, Hua-Ling; Loeb, David M.; Anhalt, Grant; Wigley, Fredrick; Jones, Richard J.; Brodsky, Robert A.

    2011-01-01

    High-dose cyclophosphamide has long been used an anticancer agent, a conditioning regimen for hematopoietic stem cell transplantation and as potent immunosuppressive agent in autoimmune diseases including aplastic anemia. High-dose cyclophosphamide is highly toxic to lymphocytes but spares hematopoietic stem cells because of their abundant levels of aldehyde dehydrogenase, the major mechanism of cyclophosphamide inactivation. High dose cyclophosphamide therapy induces durable remissions in most patients with acquired aplastic anemia. Moreover, high-dose cyclophosphamide without hematopoietic stem cell rescue has shown activity in a variety of other severe autoimmune diseases. Here we review the history of cyclophosphamide as is applies to aplastic anemia (AA) and other autoimmune diseases. Included here are the historical data from early patients treated for AA as well as an observational retrospective study in a single tertiary care hospital. This latter component was designed to assess the safety and efficacy of high-dose cyclophosphamide therapy without stem cell rescue in patients with refractory autoimmune diseases. We analyzed fully the 140 patients with severe, progressive autoimmune diseases treated. All patients discussed here received cyclophosphamide, 50 mg/kg per day for 4 consecutive days. Response, relapse and overall survival were measured. Response was defined as a decrease in disease activity in conjunction with a decrease or elimination of immune modulating drugs. Relapse was defined as worsening disease activity and/or a requirement of an increase in dose of, or administration of new, immunosuppressive medications. Hematologic recovery occurred in all patients. The overall response rate of the was 95%, and 44% of those patients remain progression-free with a median follow up time of 36 (range 1–120) months for the 140 patients analyzed together. The overall actuarial and event free survival across all diseases at 60 months is 90.7% and 20

  17. Fatal Gastrointestinal Hemorrhage in a Young Boy with Newly Diagnosed Metastatic Medulloblastoma on High Dose Dexamethasone

    Directory of Open Access Journals (Sweden)

    Victor Wong

    2014-01-01

    Full Text Available A 10-year-old boy with newly diagnosed metastatic medulloblastoma was placed on high dose dexamethasone and ranitidine prior to surgery. The child underwent subtotal resection and was discharged 5 days postoperatively with an uneventful hospital course on a tapering dose of dexamethasone and ranitidine. Over the next 2 days the patient complained of mild abdominal distension with flatulence, without pain, vomiting, or dysmotility. On follow-up in clinic 5 days after discharge, he had normal vital signs when he suddenly became pale and had loss of consciousness. Emergent computerized tomography of the head showed no acute hemorrhage and complete blood count revealed hemoglobin of 4.2 gm/dL. In spite of maximum resuscitation with copious blood products the patient died. Autopsy revealed evidence of duodenal perforation with intraluminal hemorrhage. This case demonstrates a rare fatal complication of high dose dexamethasone therapy even with concurrent gastrointestinal prophylactic therapy. We provide a review of the limited literature on steroid use in pediatric neurooncology with regard to gastrointestinal bleeding.

  18. Track structure and dose: Alternative conceptual bases for nuclear therapy

    International Nuclear Information System (INIS)

    Katz, R.

    1987-01-01

    As one departs from the island of radiation quality encompassing photons and electrons of initial energy from about 100 keV to about 10 MeV toward increasingly higher LET particle irradiations, and from relatively uniform to inherently non-uniform radiation fields, dose and LET become less useful indices of radiation effect. Isodose profiles are not isoeffect profiles. RBEs vary with end point, with the state of oxygenation, with cell line, with tissue identity and with dose, and are multiple valued functions of LET. Dose, microdose and LET lack the descrimination needed to predict biological end points. RBE calculations made from cellular radiosensitivity parameters are consistent with RBEs measured both in vitro and in vivo. For such calculations, we must know the spectrum of particles and particle energies making up a high LET radiation field. To sharpen the calculations and make them directly relevant to therapy, we need to evaluate radiosensitivity parameters for human tissues. Both physical and biological data are needed for radiobiology and radiotherapy. For the question of hazard evaluation, we need to know the relation between transformations in vitro and cancer production in vivo. Using the same model as was used earlier for cellular inactivations, we have fitted tentative radiosensitivity parameters to recent data for cell transformations. The model is consistent with both gamma ray and fission neutron measurements. But a wider range of irradiations is needed to test these results. Delta rays play an important role in heavy ion radiobiology, but we do not now know either the cross-sections for delta ray production or the radial deposition of their energy with sufficient precision or generality. But it is this, the radial dose deposition, which is the physical basis for the calculation of action cross-sections. Studies for radiobiology and radiotherapy should also include the response of different physical detectors to a range of radiations, especially

  19. Real-time Tumor Oxygenation Changes After Single High-dose Radiation Therapy in Orthotopic and Subcutaneous Lung Cancer in Mice: Clinical Implication for Stereotactic Ablative Radiation Therapy Schedule Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Song, Changhoon [Department of Radiation Oncology, Seoul National University College of Medicine, Seoul (Korea, Republic of); Hong, Beom-Ju; Bok, Seoyeon; Lee, Chan-Ju; Kim, Young-Eun [Division of Integrative Biosciences and Biotechnology, Pohang University of Science and Technology, Pohang, Gyeongbuk (Korea, Republic of); Jeon, Sang-Rok [Department of Radiation Oncology, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine, Seoul (Korea, Republic of); Wu, Hong-Gyun [Department of Radiation Oncology, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cancer Research Institute, Seoul National University College of Medicine, Seoul (Korea, Republic of); Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Yun-Sang [Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Department of Molecular Medicine and Biopharmaceutical Sciences, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cheon, Gi Jeong; Paeng, Jin Chul [Cancer Research Institute, Seoul National University College of Medicine, Seoul (Korea, Republic of); Institute of Radiation Medicine, Medical Research Center, Seoul National University College of Medicine, Seoul (Korea, Republic of); Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of); Carlson, David J. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut (United States); and others

    2016-07-01

    Purpose: To investigate the serial changes of tumor hypoxia in response to single high-dose irradiation by various clinical and preclinical methods to propose an optimal fractionation schedule for stereotactic ablative radiation therapy. Methods and Materials: Syngeneic Lewis lung carcinomas were grown either orthotopically or subcutaneously in C57BL/6 mice and irradiated with a single dose of 15 Gy to mimic stereotactic ablative radiation therapy used in the clinic. Serial [{sup 18}F]-misonidazole (F-MISO) positron emission tomography (PET) imaging, pimonidazole fluorescence-activated cell sorting analyses, hypoxia-responsive element-driven bioluminescence, and Hoechst 33342 perfusion were performed before irradiation (day −1), at 6 hours (day 0), and 2 (day 2) and 6 (day 6) days after irradiation for both subcutaneous and orthotopic lung tumors. For F-MISO, the tumor/brain ratio was analyzed. Results: Hypoxic signals were too low to quantitate for orthotopic tumors using F-MISO PET or hypoxia-responsive element-driven bioluminescence imaging. In subcutaneous tumors, the maximum tumor/brain ratio was 2.87 ± 0.483 at day −1, 1.67 ± 0.116 at day 0, 2.92 ± 0.334 at day 2, and 2.13 ± 0.385 at day 6, indicating that tumor hypoxia was decreased immediately after irradiation and had returned to the pretreatment levels at day 2, followed by a slight decrease by day 6 after radiation. Pimonidazole analysis also revealed similar patterns. Using Hoechst 33342 vascular perfusion dye, CD31, and cleaved caspase 3 co-immunostaining, we found a rapid and transient vascular collapse, which might have resulted in poor intratumor perfusion of F-MISO PET tracer or pimonidazole delivered at day 0, leading to decreased hypoxic signals at day 0 by PET or pimonidazole analyses. Conclusions: We found tumor hypoxia levels decreased immediately after delivery of a single dose of 15 Gy and had returned to the pretreatment levels 2 days after irradiation and had decreased

  20. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    International Nuclear Information System (INIS)

    Richter, Daniel; Saito, Nami; Chaudhri, Naved; Härtig, Martin; Ellerbrock, Malte; Jäkel, Oliver; Combs, Stephanie E.; Habermehl, Daniel; Herfarth, Klaus; Durante, Marco; Bert, Christoph

    2014-01-01

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V 95 ) and 107% (V 107 ) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V 95 and V 107 values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V 95 > 87%, SD < 3%) and overdose (mean V 107 < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment

  1. Impact of high-dose chemotherapy and autologous transplantation as first-line therapy on the survival of high-risk diffuse large B cell lymphoma patients: a single-center study in Japan.

    Science.gov (United States)

    Inano, Shojiro; Iwasaki, Makoto; Iwamoto, Yoshihiro; Sueki, Yuki; Fukunaga, Akiko; Yanagita, Soshi; Arima, Nobuyoshi

    2014-02-01

    High-dose chemotherapy (HDT), together with autologous stem cell transplantation (ASCT), plays an important role in the treatment of diffuse large B cell lymphoma (DLBCL), especially as second-line therapy. However, its significance in up-front settings remains to be elucidated. In our institute, patients with DLBCL in both the high-intermediate and high international prognostic index (IPI) groups initially underwent CHOP/R-CHOP treatment followed by HDT/ASCT at upfront settings between 2002 and 2011. We retrospectively analyzed 25 patients who were all treated with upfront HDT/ASCT. We excluded one patient who failed to undergo transplantation because of primary refractory disease from the analysis. The median follow-up was 77 months (range 17-110 months). Five-year overall survival (OS) and progression-free survival (PFS) were 91.7 and 79.2 %, respectively, which were higher than the equivalents in previous studies. The OS and PFS in the high-risk group were lower than those in the high-intermediate group. Treatment-related mortalities or fatal complication were not observed. Our results confirm that HDT/ASCT for high-risk aggressive lymphoma is a feasible and promising therapy, but patients with high IPI continued to have poor prognoses; improvements in treatment strategy are clearly needed. Since HDT/ASCT is an aggressive treatment option associated with long-term complications, we need to identify patient groups that will gain the maximum benefit from HDT/ASCT in the upfront setting.

  2. Prolonged high-dose intravenous magnesium therapy for severe tetanus in the intensive care unit: a case series

    Directory of Open Access Journals (Sweden)

    Fligou Fotini

    2010-03-01

    Full Text Available Abstract Introduction Tetanus rarely occurs in developed countries, but it can result in fatal complications including respiratory failure due to generalized muscle spasms. Magnesium infusion has been used to treat spasticity in tetanus, and its effectiveness is supported by several case reports and a recent randomized controlled trial. Case presentations Three Caucasian Greek men aged 30, 50 and 77 years old were diagnosed with tetanus and admitted to a general 12-bed intensive care unit in 2006 and 2007 for respiratory failure due to generalized spasticity. Intensive care unit treatment included antibiotics, hydration, enteral nutrition, early tracheostomy and mechanical ventilation. Intravenous magnesium therapy controlled spasticity without the need for additional muscle relaxants. Their medications were continued for up to 26 days, and adjusted as needed to control spasticity. Plasma magnesium levels, which were measured twice a day, remained in the 3 to 4.5 mmol/L range. We did not observe hemodynamic instability, arrhythmias or other complications related to magnesium therapy in these patients. All patients improved, came off mechanical ventilation, and were discharged from the intensive care unit in a stable condition. Conclusion In comparison with previous reports, our case series contributes the following meaningful additional information: intravenous magnesium therapy was used on patients already requiring mechanical ventilation and remained effective for up to 26 days (significantly longer than in previous reports without significant toxicity in two patients. The overall outcome was good in all our patients. However, the optimal dose, optimal duration and maximum safe duration of intravenous magnesium therapy are unknown. Therefore, until more data on the safety and efficacy of magnesium therapy are available, its use should be limited to carefully selected tetanus cases.

  3. Decision regret in men undergoing dose-escalated radiation therapy for prostate cancer.

    Science.gov (United States)

    Steer, Anna N; Aherne, Noel J; Gorzynska, Karen; Hoffman, Matthew; Last, Andrew; Hill, Jacques; Shakespeare, Thomas P

    2013-07-15

    Decision regret (DR) is a negative emotion associated with medical treatment decisions, and it is an important patient-centered outcome after therapy for localized prostate cancer. DR has been found to occur in up to 53% of patients treated for localized prostate cancer, and it may vary depending on treatment modality. DR after modern dose-escalated radiation therapy (DE-RT) has not been investigated previously, to our knowledge. Our primary aim was to evaluate DR in a cohort of patients treated with DE-RT. We surveyed 257 consecutive patients with localized prostate cancer who had previously received DE-RT, by means of a validated questionnaire. There were 220 responses (85.6% response rate). Image-guided intensity modulated radiation therapy was given in 85.0% of patients and 3-dimensional conformal radiation therapy in 15.0%. Doses received included 73.8 Gy (34.5% patients), 74 Gy (53.6%), and 76 Gy (10.9%). Neoadjuvant androgen deprivation (AD) was given in 51.8% of patients and both neoadjuvant and adjuvant AD in 34.5%. The median follow-up time was 23 months (range, 12-67 months). In all, 3.8% of patients expressed DR for their choice of treatment. When asked whether they would choose DE-RT or AD again, only 0.5% probably or definitely would not choose DE-RT again, compared with 8.4% for AD (P<.01). Few patients treated with modern DE-RT express DR, with regret appearing to be lower than in previously published reports of patients treated with radical prostatectomy or older radiation therapy techniques. Patients experienced more regret with the AD component of treatment than with the radiation therapy component, with implications for informed consent. Further research should investigate regret associated with individual components of modern therapy, including AD, radiation therapy and surgery. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  4. Decision Regret in Men Undergoing Dose-Escalated Radiation Therapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Steer, Anna N.; Aherne, Noel J.; Gorzynska, Karen; Hoffman, Matthew; Last, Andrew; Hill, Jacques; Shakespeare, Thomas P.

    2013-01-01

    Purpose: Decision regret (DR) is a negative emotion associated with medical treatment decisions, and it is an important patient-centered outcome after therapy for localized prostate cancer. DR has been found to occur in up to 53% of patients treated for localized prostate cancer, and it may vary depending on treatment modality. DR after modern dose-escalated radiation therapy (DE-RT) has not been investigated previously, to our knowledge. Our primary aim was to evaluate DR in a cohort of patients treated with DE-RT. Methods and Materials: We surveyed 257 consecutive patients with localized prostate cancer who had previously received DE-RT, by means of a validated questionnaire. Results: There were 220 responses (85.6% response rate). Image-guided intensity modulated radiation therapy was given in 85.0% of patients and 3-dimensional conformal radiation therapy in 15.0%. Doses received included 73.8 Gy (34.5% patients), 74 Gy (53.6%), and 76 Gy (10.9%). Neoadjuvant androgen deprivation (AD) was given in 51.8% of patients and both neoadjuvant and adjuvant AD in 34.5%. The median follow-up time was 23 months (range, 12-67 months). In all, 3.8% of patients expressed DR for their choice of treatment. When asked whether they would choose DE-RT or AD again, only 0.5% probably or definitely would not choose DE-RT again, compared with 8.4% for AD (P<.01). Conclusion: Few patients treated with modern DE-RT express DR, with regret appearing to be lower than in previously published reports of patients treated with radical prostatectomy or older radiation therapy techniques. Patients experienced more regret with the AD component of treatment than with the radiation therapy component, with implications for informed consent. Further research should investigate regret associated with individual components of modern therapy, including AD, radiation therapy and surgery

  5. Decision Regret in Men Undergoing Dose-Escalated Radiation Therapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Steer, Anna N. [Department of Radiation Oncology, North Coast Cancer Institute, Coffs Harbour (Australia); Aherne, Noel J., E-mail: noel.aherne@ncahs.health.nsw.gov.au [Department of Radiation Oncology, North Coast Cancer Institute, Coffs Harbour (Australia); Rural Clinical School Faculty of Medicine, University of New South Wales, Coffs Harbour (Australia); Gorzynska, Karen; Hoffman, Matthew; Last, Andrew; Hill, Jacques [Department of Radiation Oncology, North Coast Cancer Institute, Coffs Harbour (Australia); Shakespeare, Thomas P. [Department of Radiation Oncology, North Coast Cancer Institute, Coffs Harbour (Australia); Rural Clinical School Faculty of Medicine, University of New South Wales, Coffs Harbour (Australia)

    2013-07-15

    Purpose: Decision regret (DR) is a negative emotion associated with medical treatment decisions, and it is an important patient-centered outcome after therapy for localized prostate cancer. DR has been found to occur in up to 53% of patients treated for localized prostate cancer, and it may vary depending on treatment modality. DR after modern dose-escalated radiation therapy (DE-RT) has not been investigated previously, to our knowledge. Our primary aim was to evaluate DR in a cohort of patients treated with DE-RT. Methods and Materials: We surveyed 257 consecutive patients with localized prostate cancer who had previously received DE-RT, by means of a validated questionnaire. Results: There were 220 responses (85.6% response rate). Image-guided intensity modulated radiation therapy was given in 85.0% of patients and 3-dimensional conformal radiation therapy in 15.0%. Doses received included 73.8 Gy (34.5% patients), 74 Gy (53.6%), and 76 Gy (10.9%). Neoadjuvant androgen deprivation (AD) was given in 51.8% of patients and both neoadjuvant and adjuvant AD in 34.5%. The median follow-up time was 23 months (range, 12-67 months). In all, 3.8% of patients expressed DR for their choice of treatment. When asked whether they would choose DE-RT or AD again, only 0.5% probably or definitely would not choose DE-RT again, compared with 8.4% for AD (P<.01). Conclusion: Few patients treated with modern DE-RT express DR, with regret appearing to be lower than in previously published reports of patients treated with radical prostatectomy or older radiation therapy techniques. Patients experienced more regret with the AD component of treatment than with the radiation therapy component, with implications for informed consent. Further research should investigate regret associated with individual components of modern therapy, including AD, radiation therapy and surgery.

  6. Pre-therapeutic blood dosimetry in patients with differentiated thyroid carcinoma using 124-iodine. Predicted blood doses correlate with changes in blood cell counts after radioiodine therapy and depend on modes of TSH stimulation and number of preceding radioiodine therapies

    International Nuclear Information System (INIS)

    Hartung-Knemeyer, V.; Nagarajah, J.; Jentzen, W.; Ruhlmann, M.; Freudenberg, L.S.; Stahl, A.R.; Bockisch, A.; Rosenbaum-Krumme, S.J.

    2012-01-01

    Pre-therapeutic blood dosimetry prior to a high-dose radioiodine therapy (RAIT) is recommended and a blood dose of 2 Gy is considered to be safe. In this study, changes in the blood cell count after radioiodine therapy of high risk differentiated thyroid carcinoma (DTC) were analyzed and compared with the results of the pre-therapeutic blood dosimetry using 124 I. Moreover, the influence of different modes of TSH stimulation and the number of preceding radioiodine therapies on the blood dose were assessed. 198 patients with locally advanced or metastasized DTC received a pre-therapeutic blood dosimetry using 124 I. To analyze the influence of the modes of TSH stimulation and the number of preceding RAITs on blood dose subgroups were built as follows: patients with endogenous TSH stimulation versus patients with exogenous TSH stimulation and patients with no preceding RAIT versus patients with at least one preceding RAIT. In 124/198 patients subsequent RAIT was performed. In 73/124 patients, hemograms were performed from day 2 to 12 month after RAIT. There was no high-grade bone marrow toxicity (id est (i.e.) ≥grade 3) in patients receiving less than 2 Gy blood dose-independent of the therapeutic history. Within the first month after radioiodine therapy, there was an overall decrease in the white blood cell and platelet counts. The erythrocyte count was essentially stable. There was a correlation between cell count decrease and predicted blood doses (Spearman's correlation coefficient >-0.6 each) for the white cell line and the platelets. With regard to the subgroups, the blood dose per administered 131 I activity (BDpA) was significantly higher in patients with endogenous TSH stimulation (median 0.08 Gy/GBq) than in patients with exogenous TSH stimulation (0.06 Gy/GBq) and in patients with no previous RAIT (0.08 Gy/GBq) compared to patients who had previously undergone at least one RAIT (0.07 Gy/GBq). The range of BDpA among DTC patients is rather wide. Our

  7. Dose distribution and clinical response of glioblastoma treated with boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, M. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan)], E-mail: mhide-m@gk9.so-net.ne.jp; Yamamoto, T. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan); Kumada, H. [Japan Atomic Energy Agency, Shirakatashirane 2-4, Tokai (Japan); Nakai, K.; Shirakawa, M.; Tsurubuchi, T.; Matsumura, A. [Department of Neurosurgery, Graduate School of Comprehensive Human Science, University of Tsukuba, Tennodai 1-1-1, Tsukuba (Japan)

    2009-07-15

    The dose distribution and failure pattern after treatment with the external beam boron neutron capture therapy (BNCT) protocol were retrospectively analyzed. BSH (5 g/body) and BPA (250 mg/kg) based BNCT was performed in eight patients with newly diagnosed glioblastoma. The gross tumor volume (GTV) and clinical target volume (CTV)-1 were defined as the residual gadolinium-enhancing volume. CTV-2 and CTV-3 were defined as GTV plus a margin of 2 and 3 cm, respectively. As additional photon irradiation, a total X-ray dose of 30 Gy was given to the T2 high intensity area on MRI. Five of the eight patients were alive at analysis for a mean follow-up time of 20.3 months. The post-operative median survival time of the eight patients was 27.9 months (95% CI=21.0-34.8). The minimum tumor dose of GTV, CTV-2, and CTV-3 averaged 29.8{+-}9.9, 15.1{+-}5.4, and 12.4{+-}2.9 Gy, respectively. The minimum tumor non-boron dose of GTV, CTV-2, and CTV-3 averaged 2.0{+-}0.5, 1.3{+-}0.3, and 1.1{+-}0.2 Gy, respectively. The maximum normal brain dose, skin dose, and average brain dose were 11.4{+-}1.5, 9.6{+-}1.4, and 3.1{+-}0.4 Gy, respectively. The mean minimum dose at the failure site in cases of in-field recurrence (IR) and out-field recurrence (OR) was 26.3{+-}16.7 and 14.9 GyEq, respectively. The calculated doses at the failure site were at least equal to the tumor control doses which were previously reported. We speculate that the failure pattern was related to an inadequate distribution of boron-10. Further improvement of the microdistribution of boron compounds is expected, and may improve the tumor control by BNCT.

  8. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  9. SU-E-T-66: Characterization of Radiation Dose Associated with Dark Currents During Beam Hold for Respiratory-Gated Electron Therapy

    International Nuclear Information System (INIS)

    Hessler, J; Gupta, N; Rong, Y; Weldon, M

    2014-01-01

    Purpose: The main objective of this study was to estimate the radiation dose contributed by dark currents associated with the respiratory-gated electron therapy during beam hold. The secondary aim was to determine clinical benefits of using respiratory-gated electron therapy for left-sided breast cancer patients with positive internal mammary nodes (IMN). Methods: Measurements of the dark current-induced dose in all electron modes were performed on multiple Siemens and Varian linear accelerators by manually simulating beam-hold during respiratory gating. Dose was quantified at the machine isocenter by comparing the collected charge to the known output for all energies ranging from 6 to 18 MeV for a 10cm × 10cm field at 100 SSD with appropriate solid-water buildup. Using the Eclipse treatment planning system, we compared the additional dose associated with dark current using gated electron fields to the dose uncertainties associated with matching gated photon fields and ungated electron fields. Dose uncertainties were seen as hot and cold spots along the match line of the fields. Results: The magnitude of the dose associated with dark current is highly correlated to the energy of the beam and the amount of time the beam is on hold. For lower energies (6–12 MeV), there was minimal dark current dose (0.1–1.3 cGy/min). Higher energies (15–18 MeV) showed measurable amount of doses. The dark current associated with the electron beam-hold varied between linear accelerator vendors and depended on dark current suppression and the age of the linear accelerator. Conclusion: For energies up to 12 MeV, the dose associated with the dark current for respiratorygated electron therapy was shown to be negligible, and therefore should be considered an option for treating IMN positive left-sided breast cancer patients. However, at higher energies the benefit of respiratory gating may be outweighed by dose due to the dark current

  10. Comparison of dose measurements in water versus in air for therapy

    International Nuclear Information System (INIS)

    Nasukha

    1987-01-01

    Comparison of dose measurements in water versus in air for therapy. Dose measurements in water and in the air had been done by teletherapy unit Co-60 Picker Model V 4m/60 with Farmer dosimeter. The result of inverse square law, TAR, PDD, and PSF compared to BJR No. 17 produced a difference of more than 4,65% with SSD 80 cm. Doses in water calculated from the result of dose measurement in air using BJR tables given, was compared with direct dose measurement in water. Values of 0,9850 to 1,0302 were obtained if using inverse square law, PDD and PSF formula. Using inverse square law and TAR, values of 0,9474 to 1,0197 were obtained for 4 depths and 5 field sizes. Measurements done in 5 cm depth and 10 cm x 10 cm field size using both methods, were still good. (author). 7 figs, 8 refs

  11. Survival of tumor cells after proton irradiation with ultra-high dose rates

    International Nuclear Information System (INIS)

    Auer, Susanne; Hable, Volker; Greubel, Christoph; Drexler, Guido A; Schmid, Thomas E; Belka, Claus; Dollinger, Günther; Friedl, Anna A

    2011-01-01

    Laser acceleration of protons and heavy ions may in the future be used in radiation therapy. Laser-driven particle beams are pulsed and ultra high dose rates of >10 9 Gy s -1 may be achieved. Here we compare the radiobiological effects of pulsed and continuous proton beams. The ion microbeam SNAKE at the Munich tandem accelerator was used to directly compare a pulsed and a continuous 20 MeV proton beam, which delivered a dose of 3 Gy to a HeLa cell monolayer within < 1 ns or 100 ms, respectively. Investigated endpoints were G2 phase cell cycle arrest, apoptosis, and colony formation. At 10 h after pulsed irradiation, the fraction of G2 cells was significantly lower than after irradiation with the continuous beam, while all other endpoints including colony formation were not significantly different. We determined the relative biological effectiveness (RBE) for pulsed and continuous proton beams relative to x-irradiation as 0.91 ± 0.26 and 0.86 ± 0.33 (mean and SD), respectively. At the dose rates investigated here, which are expected to correspond to those in radiation therapy using laser-driven particles, the RBE of the pulsed and the (conventional) continuous irradiation mode do not differ significantly

  12. Contribution to the study of nuclear processes in hadron therapy and their impact on the dose deposition delocalization

    International Nuclear Information System (INIS)

    Ricol, M.Ch.

    2008-11-01

    This work aims to improve the predictive power of monte Carlo simulation programmes of the volume distributions of dose deposit in hadron therapy. The monte Carlo simulations show the electromagnetic interactions in hadron therapy but not the nuclear interactions responsible of a dose deposit relocation. A better quantification of these nuclear phenomena in order to get a more precise knowledge of the dose deposit relocation constitutes the object of this work. (N.C.)

  13. Comparative evaluation of the two fixed dose methods of radioiodine therapy (185 MBq and 370 MBq) for the treatment of Graves' disease

    International Nuclear Information System (INIS)

    Esfahani, A.F.; Fallahi, B.; Kakhki, V.R.D.; Eftekhari, M.; Beiki, D.; Saghari, M.

    2005-01-01

    radioiodine was significant (P<0.003).Discussion: Although the incidence rate of early hypothyroidism (by the end of 2 years) in the group treated with 185 MBq is less than those treated with 370 MBq, the incidence of failed therapy is higher in the former group. In addition, long-term hypothyroidism prevalence is not significantly different by using different doses of I-131. On the other hand, if the initial dose is so little to cure, cost and time for perfect treatment, number of office visits and morbidity due to untreated hyperthyroidism are markedly increased. Conclusion: Regarding lower rate of failed therapy with 370 MBq, and as there is no significant difference in late hypothyroidism between low doses and high doses of I-131, we concluded that 370 MBq is the optimal fixed dose for treatment of Graves' disease. (author)

  14. Studies on the dose distribution and treatment technique of high energy electron beams

    International Nuclear Information System (INIS)

    Lee, D.H.; Chu, S.S.

    1978-01-01

    Some important properties of high energy electron beams from the linear accelerator, LMR-13, installed in the Yonsei Cancer Center were studied. The results of experimental studies on the problems associated with the 8, 10, and 12 MeV electron beam therapy were as followings; The ionization type dosemeters calibrated by 90 Sr standard source were suitable to the measurements of the outputs and the obsorbed doses in accuracy point of view, and dose measurements using ionization chambers were difficult when measuring doses in small field size and the regions of rapid fall off. The electron energies were measured precisely with an energy spectrometer, and the practical electron energy was calculated within 5% error in the maximum range of the high energy electron beam in water. The correcting factors of perturbated dose distributions owing to radiation field, energy, and materials of the treatment cone were checked and described systematically and thus the variation of dose distributions due to the non-homogeneities of tissues and slopping skin surfaces were completely compensated. The electron beams were adequately diffused using the scatterers, and minimized the bremsstrahlung, irradiation field size, and materials of scatterers. Thus, the therapeutic capacity with the limited electron energy could be extended by improving the dose distributions. (author)

  15. Is volumetric modulated arc therapy with constant dose rate a valid option in radiation therapy for head and neck cancer patients?

    Science.gov (United States)

    Didona, Annamaria; Lancellotta, Valentina; Zucchetti, Claudio; Panizza, Bianca Moira; Frattegiani, Alessandro; Iacco, Martina; Di Pilato, Anna Concetta; Saldi, Simonetta; Aristei, Cynthia

    2018-01-01

    Intensity-modulated radiotherapy (IMRT) improves dose distribution in head and neck (HN) radiation therapy. Volumetric-modulated arc therapy (VMAT), a new form of IMRT, delivers radiation in single or multiple arcs, varying dose rates (VDR-VMAT) and gantry speeds, has gained considerable attention. Constant dose rate VMAT (CDR-VMAT) associated with a fixed gantry speed does not require a dedicated linear accelerator like VDR-VMAT. The present study explored the feasibility, efficiency and delivery accuracy of CDR-VMAT, by comparing it with IMRT and VDR-VMAT in treatment planning for HN cancer. Step and shoot IMRT (SS-IMRT), CDR-VMAT and VDR-VMAT plans were created for 15 HN cancer patients and were generated by Pinnacle 3 TPS (v 9.8) using 6 MV photon energy. Three PTVs were defined to receive respectively prescribed doses of 66 Gy, 60 Gy and 54 Gy, in 30 fractions. Organs at risk (OARs) included the mandible, spinal cord, brain stem, parotids, salivary glands, esophagus, larynx and thyroid. SS-IMRT plans were based on 7 co-planar beams at fixed gantry angles. CDR-VMAT and VDR-VMAT plans, generated by the SmartArc module, used a 2-arc technique: one clockwise from 182° to 178° and the other one anti-clockwise from 178° to 182°. Comparison parameters included dose distribution to PTVs ( D mean , D 2% , D 50% , D 95% , D 98% and Homogeneity Index), maximum or mean doses to OARs, specific dose-volume data, the monitor units and treatment delivery times. Compared with SS-IMRT, CDR-VMAT significantly reduced the maximum doses to PTV1 and PTV2 and significantly improved all PTV3 parameters, except D 98% and D 95% . It significantly spared parotid and submandibular glands and was associated with a lower D mean to the larynx. Compared with VDR-VMAT, CDR-VMAT was linked to a significantly better D mean , to the PTV3 but results were worse for the parotids, left submandibular gland, esophagus and mandible. Furthermore, the D mean to the larynx was also worse

  16. Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer

    International Nuclear Information System (INIS)

    Ashamalla, Hani; Tejwani, Ajay; Parameritis, Loannis; Swamy, Uma; Luo, Pei Ching; Guirguis, Adel; Lavaf, Amir

    2013-01-01

    Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Sixteen patients were studied. Prostate (PTV P ), right pelvic (PTV RtLN ) and left pelvic lymph nodes (PTV LtLN ), and organs at risk were contoured. PTVP, PTV RtLN , and PTV LtLN received 50.40 Gy followed by a boost to PTV B of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose (D MEAN ) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The D MEAN of bladder was within 2% of each other. The rectum D MEAN in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.

  17. Cost-effectiveness analysis of cochlear dose reduction by proton beam therapy for medulloblastoma in childhood

    International Nuclear Information System (INIS)

    Hirano, Emi; Kawabuchi, Koichi; Fuji, Hiroshi; Onoe, Tsuyoshi; Kumar, Vinay; Shirato, Hiroki

    2014-01-01

    The aim of this study is to evaluate the cost-effectiveness of proton beam therapy with cochlear dose reduction compared with conventional X-ray radiotherapy for medulloblastoma in childhood. We developed a Markov model to describe health states of 6-year-old children with medulloblastoma after treatment with proton or X-ray radiotherapy. The risks of hearing loss were calculated on cochlear dose for each treatment. Three types of health-related quality of life (HRQOL) of EQ-5D, HUI3 and SF-6D were used for estimation of quality-adjusted life years (QALYs). The incremental cost-effectiveness ratio (ICER) for proton beam therapy compared with X-ray radiotherapy was calculated for each HRQOL. Sensitivity analyses were performed to model uncertainty in these parameters. The ICER for EQ-5D, HUI3 and SF-6D were $21 716/QALY, $11 773/QALY, and $20 150/QALY, respectively. One-way sensitivity analyses found that the results were sensitive to discount rate, the risk of hearing loss after proton therapy, and costs of proton irradiation. Cost-effectiveness acceptability curve analysis revealed a 99% probability of proton therapy being cost effective at a societal willingness-to-pay value. Proton beam therapy with cochlear dose reduction improves health outcomes at a cost that is within the acceptable cost-effectiveness range from the payer's standpoint. (author)

  18. SU-F-BRD-14: Dose Weighted Linear Energy Transfer Analysis of Critical Structures in Proton Therapy of Pediatric Brain Tumor Patients

    Energy Technology Data Exchange (ETDEWEB)

    Pirlepesov, F.; Shin, J.; Moskvin, V. P.; Gray, J.; Hua, C.; Gajjar, A.; Krasin, M. J.; Merchant, T. E.; Farr, J. B. [St. Jude Children’s Research Hospital, Memphis, TN (United States); Li, Z. [University of Florida Proton Therapy Institute, Jacksonville, FL (United States)

    2015-06-15

    Purpose: Dose weighted Linear Energy Transfer (LETd) analysis of critical structures may be useful in understanding the side effects of the proton therapy. The objective is to analyze the differences between LETd and dose distributions in brain tumor patients receiving double scattering proton therapy, to quantify LETd variation in critical organs, and to identify beam arrangements contributing to high LETd in critical organs. Methods: Monte Carlo simulations of 9 pediatric brain tumor patients were performed. The treatment plans were reconstructed with the TOPAS Monte Carlo code to calculate LETd and dose. The beam data were reconstructed proximal to the aperture of the double scattering nozzle. The dose and LETd to target and critical organs including brain stem, optic chiasm, lens, optic nerve, pituitary gland, and hypothalamus were computed for each beam. Results: Greater variability in LETd compared to dose was observed in the brainstem for patients with a variety of tumor types including 5 patients with tumors located in the posterior fossa. Approximately 20%–44% brainstem volume received LETd of 5kev/µm or greater from beams within gantry angles 180°±30° for 5 patients treated with a 3 beam arrangement. Critical organs received higher LETd when located in the vicinity of the beam distal edge. Conclusion: This study presents a novel strategy in the evaluation of the proton treatment impact on critical organs. While the dose to critical organs is confined below the required limits, the LETd may have significant variation. Critical organs in the vicinity of beam distal edge receive higher LETd and depended on beam arrangement, e.g. in posterior fossa tumor treatment, brainstem receive higher LETd from posterior-anterior beams. This study shows importance of the LETd analysis of the radiation impact on the critical organs in proton therapy and may be used to explain clinical imaging observations after therapy.

  19. High-energy extracorporeal shock wave therapy as a treatment for chronic noninsertional Achilles tendinopathy.

    Science.gov (United States)

    Furia, John P

    2008-03-01

    High-energy extracorporeal shock wave therapy has been shown to be an effective treatment for chronic insertional Achilles tendinopathy. The results of high-energy shock wave therapy for chronic noninsertional Achilles tendinopathy have not been determined. Shock wave therapy is an effective treatment for noninsertional Achilles tendinopathy. Case control study; Level of evidence, 3. Thirty-four patients with chronic noninsertional Achilles tendinopathy were treated with a single dose of high-energy shock wave therapy (shock wave therapy group; 3000 shocks; 0.21 mJ/mm(2); total energy flux density, 604 mJ/mm(2)). Thirty-four patients with chronic noninsertional Achilles tendinopathy were treated not with shock wave therapy but with additional forms of nonoperative therapy (control group). All shock wave therapy procedures were performed using regional anesthesia. Evaluation was by change in visual analog score and by Roles and Maudsley score. One month, 3 months, and 12 months after treatment, the mean visual analog scores for the control and shock wave therapy groups were 8.4 and 4.4 (P wave therapy and control groups were 12 and 0 (P wave therapy group than in the control group (P wave therapy is an effective treatment for chronic noninsertional Achilles tendinopathy.

  20. Mobilization of peripheral blood progenitor cells by chemotherapy and granulocyte-macrophage colony-stimulating factor for hematologic support after high-dose intensification for breast cancer.

    Science.gov (United States)

    Elias, A D; Ayash, L; Anderson, K C; Hunt, M; Wheeler, C; Schwartz, G; Tepler, I; Mazanet, R; Lynch, C; Pap, S

    1992-06-01

    High-dose therapy with autologous marrow support results in durable complete remissions in selected patients with relapsed lymphoma and leukemia who cannot be cured with conventional dose therapy. However, substantial morbidity and mortality result from the 3- to 6-week period of marrow aplasia until the reinfused marrow recovers adequate hematopoietic function. Hematopoietic growth factors, particularly used after chemotherapy, can increase the number of peripheral blood progenitor cells (PBPCs) present in systemic circulation. The reinfusion of PBPCs with marrow has recently been reported to reduce the time to recovery of adequate marrow function. This study was designed to determine whether granulocyte-macrophage colony-stimulating factor (GM-CSF)-mobilized PBPCs alone (without marrow) would result in rapid and reliable hematopoietic reconstitution. Sixteen patients with metastatic breast cancer were treated with four cycles of doxorubicin, 5-fluorouracil, and methotrexate (AFM induction). Patients responding after the first two cycles were administered GM-CSF after the third and fourth cycles to recruit PBPCs for collection by two leukapheresis per cycle. These PBPCs were reinfused as the sole source of hematopoietic support after high doses of cyclophosphamide, thiotepa, and carboplatin. No marrow or hematopoietic cytokines were used after progenitor cell reinfusion. Granulocytes greater than or equal to 500/microL was observed on a median of day 14 (range, 8 to 57). Transfusion independence of platelets greater than or equal to 20,000/microL occurred on a median day of 12 (range, 8 to 134). However, three patients required the use of a reserve marrow for slow platelet engraftment. In retrospect, these patients were characterized by poor baseline bone marrow cellularity and poor platelet recovery after AFM induction therapy. When compared with 29 historical control patients who had received the same high-dose intensification chemotherapy using autologous

  1. High-dose antibiotic therapy is superior to a 3-drug combination of prostanoids and lipid A derivative in protecting irradiated canines

    International Nuclear Information System (INIS)

    Kumar, K.S.; Srinivasan, V.; Toles, R.E.; Miner, V.L.; Jackson, W.E.; Seed, T.M.

    2002-01-01

    There is an urgent need to develop non-toxic radioprotectors. We tested the efficacy of a 3-drug combination (3-DC) of iloprost, misoprostol, and 3D-MPL (3-deacylated monophosphoryl lipid A) and the effects of postirradiation clinical support with high doses of antibiotics and blood transfusion. Canines were given 3-DC or the vehicle and exposed to 3.4 Gy or 4.1 Gy of 60 Co radiation. Canines irradiated at 4.1 Gy were also given clinical support, which consisted of blood transfusion and antibiotics (gentamicin, and cefoxitin or cephalexin). Peripheral blood cell profile and 60-day survival were used as indices of protection. At 3.4 Gy, 3-DC- or vehicle-treated canines without postirradiation clinical support survived only for 10 to 12 days. Fifty percent of the canines treated with 3-DC or vehicle and provided postirradiation clinical support survived 4.1-Gy irradiation. Survival of canines treated with vehicle before irradiation significantly correlated with postirradiation antibiotic treatments, but not with blood transfusion. The recovery profile of peripheral blood cells in 4.1 Gy-irradiated canines treated with vehicle and antibiotics was better than drug-treated canines. These results indicate that therapy with high doses of intramuscular aminoglycoside antibiotic (gentamicin) and an oral cephalosporin (cephalexin) enhanced survival of irradiated canines. Although blood transfusion correlated with survival of 3-DC treated canines, there were no additional survivors with 3-DC treated canines than the controls. (author)

  2. Treating tuberculosis with high doses of anti-TB drugs: mechanisms and outcomes.

    Science.gov (United States)

    Xu, Yuhui; Wu, Jianan; Liao, Sha; Sun, Zhaogang

    2017-10-03

    Tuberculosis (TB) is considered as one of the most serious threats to public health in many parts of the world. The threat is even more severe in the developing countries where there is a lack of advanced medical amenities and contemporary anti-TB drugs. In such situations, dosage optimization of existing medication regimens seems to be the only viable option. Therapeutic drug monitoring study results suggest that high-dose treatment regimens can compensate the low serum concentration of anti-TB drugs and shorten the therapy duration. The article presents a critical review on the possible changes that occur in the host and the pathogen upon the administration of standard and high-dose regimens. Some of the most common factors that are responsible for low anti-TB drug concentrations in the serum are differences in hosts' body weight, metabolic processing of the drug, malabsorption and/or drug-drug interaction. Furthermore, failure to reach the cavitary pulmonary and extrapulmonary tissues also contributes to the therapeutic inefficiency of the drugs. In such conditions, administration of higher doses can help in compensating the pathogenic outcomes of enhancement of the pathogen's physical barriers, efflux pumps and genetic mutations. The present article also presents a summary of the recorded treatment outcomes of clinical trials that were conducted to test the efficacy of administration of high dose of anti-tuberculosis drugs. This review will help physicians across the globe to understand the underlying pathophysiological changes (including side effects) that dictate the clinical outcomes in patients administered with standard and/or high dose anti-TB drugs.

  3. Desensitization Using Bortezomib and High-dose Immunoglobulin Increases Rate of Deceased Donor Kidney Transplantation.

    Science.gov (United States)

    Jeong, Jong Cheol; Jambaldorj, Enkthuya; Kwon, Hyuk Yong; Kim, Myung-Gyu; Im, Hye Jin; Jeon, Hee Jung; In, Ji Won; Han, Miyeun; Koo, Tai Yeon; Chung, Junho; Song, Eun Young; Ahn, Curie; Yang, Jaeseok

    2016-02-01

    Combination therapy of intravenous immunoglobulin (IVIG) and rituximab showed a good transplant rate in highly sensitized wait-listed patients for deceased donor kidney transplantation (DDKT), but carried the risk of antibody-mediated rejection. The authors investigated the impact of a new combination therapy of bortezomib, IVIG, and rituximab on transplantation rate.This study was a prospective, open-labeled clinical trial. The desensitization regimen consisted of 2 doses of IVIG (2  g/kg), a single dose of rituximab (375  mg/m), and 4 doses of bortezomib (1.3  mg/m). The transplant rate was analyzed. Anti-Human leukocyte antigen (HLA) DRB antibodies were determined by a Luminex solid-phase bead assay at baseline and after 2, 3, and 6 months in the desensitized patients.There were 19 highly sensitized patients who received desensitization and 17 patients in the control group. Baseline values of class I and II panel reactive antibody (%, peak mean fluorescence intensity) were 83  ±  16.0 (14952  ±  5820) and 63  ±  36.0 (10321  ±  7421), respectively. Deceased donor kidney transplantation was successfully performed in 8 patients (42.1%) in the desensitization group versus 4 (23.5%) in the control group. Multivariate time-varying covariate Cox regression analysis showed that desensitization increased the probability of DDKT (hazard ratio, 46.895; 95% confidence interval, 3.468-634.132; P = 0.004). Desensitization decreased mean fluorescence intensity values of class I panel reactive antibody by 15.5% (20.8%) at 2 months. In addition, a liberal mismatch strategy in post hoc analysis increased the benefit of desensitization in donor-specific antibody reduction. Desensitization was well tolerated, and acute rejection occurred only in the control group.In conclusion, a desensitization protocol using bortezomib, high-dose IVIG, and rituximab increased the DDKT rate in highly sensitized, wait-listed patients.

  4. Lithium formate EPR dosimetry for verifications of planned dose distributions prior to intensity-modulated radiation therapy

    Science.gov (United States)

    Gustafsson, H.; Lund, E.; Olsson, S.

    2008-09-01

    The objective of the present investigation was to evaluate lithium formate electron paramagnetic resonance (EPR) dosimetry for measurement of dose distributions in phantoms prior to intensity-modulated radiation therapy (IMRT). Lithium formate monohydrate tablets were carefully prepared, and blind tests were performed in clinically relevant situations in order to determine the precision and accuracy of the method. Further experiments confirmed that within the accuracy of the current method, the dosimeter response was independent of beam energies and dose rates used for IMRT treatments. The method was applied to IMRT treatment plans, and the dose determinations were compared to ionization chamber measurements. The experiments showed that absorbed doses above 3 Gy could be measured with an uncertainty of less than 2.5% of the dose (coverage factor k = 1.96). Measurement time was about 15 min using a well-calibrated dosimeter batch. The conclusion drawn from the investigation was that lithium formate EPR dosimetry is a promising new tool for absorbed dose measurements in external beam radiation therapy, especially for doses above 3 Gy.

  5. Lithium formate EPR dosimetry for verifications of planned dose distributions prior to intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, H; Lund, E [Department of Medical and Health Sciences, Radiation Physics, Faculty of Health Sciences, Linkoeping University, S-581 85 Linkoeping (Sweden); Olsson, S [Division of Radiation Physics, Linkoeping University Hospital, S-581 85 Linkoeping (Sweden)], E-mail: hakgu@imv.liu.se

    2008-09-07

    The objective of the present investigation was to evaluate lithium formate electron paramagnetic resonance (EPR) dosimetry for measurement of dose distributions in phantoms prior to intensity-modulated radiation therapy (IMRT). Lithium formate monohydrate tablets were carefully prepared, and blind tests were performed in clinically relevant situations in order to determine the precision and accuracy of the method. Further experiments confirmed that within the accuracy of the current method, the dosimeter response was independent of beam energies and dose rates used for IMRT treatments. The method was applied to IMRT treatment plans, and the dose determinations were compared to ionization chamber measurements. The experiments showed that absorbed doses above 3 Gy could be measured with an uncertainty of less than 2.5% of the dose (coverage factor k = 1.96). Measurement time was about 15 min using a well-calibrated dosimeter batch. The conclusion drawn from the investigation was that lithium formate EPR dosimetry is a promising new tool for absorbed dose measurements in external beam radiation therapy, especially for doses above 3 Gy.

  6. A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

    International Nuclear Information System (INIS)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-01-01

    Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

  7. A dosimetric comparison of tomotherapy and volumetric modulated arc therapy in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy.

    Science.gov (United States)

    Pasquier, David; Cavillon, Fabrice; Lacornerie, Thomas; Touzeau, Claire; Tresch, Emmanuelle; Lartigau, Eric

    2013-02-01

    To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. For WPRT, HT was able to provide a higher D98% than VMAT (44.3 ± 0.3 Gy and 43.9 ± 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 ± 0.3 Gy and 49.1 ± 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 ± 0.009) than with VMAT (0.80 ± 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 ± 0.1 vs 7.4 ± 0.6 min, respectively; P=.002, and 1.5 ± 0.05 vs 3.7 ± 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Rectal dose sparing with a balloon catheter and ultrasound localization in conformal radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Patel, Rakesh R.; Orton, Nigel; Tome, Wolfgang A.; Chappell, Rick; Ritter, Mark A.

    2003-01-01

    Background and purpose: To compare the rectal wall and bladder volume in the high dose region with or without the use of a balloon catheter with both three-dimensional (3D)-conformal and intensity modulated radiation therapy (CRT, IMRT) approaches in the treatment of prostate cancer. Material and methods: Five patients with a wide range of prostate volumes and treated with primary external beam radiation therapy for localized prostate cancer were selected for analysis. Pinnacle TM treatment plans were generated utilizing a 3D conformal six-field design and an IMRT seven coplanar-field plan with a novel, three-step optimization and with ultrasound localization. Separate plans were devised with a rectal balloon deflated or air inflated with and without inclusion of the seminal vesicles (SV) in the target volume. The prescription dose was 76 Gy in 38 fractions of 2 Gy each. Cumulative dose-volume histograms (DVHs) were analyzed for the planning target volume (PTV), rectal wall, and bladder with an inflated (60 cc air) or deflated balloon with and without SV included. The volumes of rectal wall and bladder above 60, 65, and 70 Gy with each treatment approach were evaluated. Results: Daily balloon placement was well-tolerated with good patient positional reproducibility. Inflation of the rectal balloon in all cases resulted in a significant decrease in the absolute volume of rectal wall receiving greater than 60, 65, or 70 Gy. The rectal sparing ratio (RSR), consisting of a structure's high dose volume with the catheter inflated, divided by the volume with the catheter deflated, was calculated for each patient with and without seminal vesicle inclusion for 3D-CRT and IMRT. For 3D-CRT, RSRs with SV included were 0.59, 0.59, and 0.56 and with SV excluded were 0.60, 0.58, and 0.54 at doses of greater than 60, 65, and 70 Gy, respectively. Similarly, for IMRT, the mean RSRs were 0.59, 0.59, and 0.63 including SV and 0.71, 0.66, and 0.67 excluding SV at these same dose levels

  9. Dose planning and dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Knoeoes, T.

    1991-01-01

    A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, making an objective evaluation of dose calculations with experiments feasible. The methods for electron density determination, dose calculation and prediction of accelerator output discussed in this study will all contribute to an increased accuracy in the mean absorbed dose to the target volume. However, a substantial gain in the accuracy for the spatial absorbed dose distribution will also follow, especially using CT for mapping of electron density together with the dose calculation algorithm. (au)

  10. Modern Radiation Therapy for Hodgkin Lymphoma: Field and Dose Guidelines From the International Lymphoma Radiation Oncology Group (ILROG)

    International Nuclear Information System (INIS)

    Specht, Lena; Yahalom, Joachim; Illidge, Tim; Berthelsen, Anne Kiil; Constine, Louis S.; Eich, Hans Theodor; Girinsky, Theodore; Hoppe, Richard T.; Mauch, Peter; Mikhaeel, N. George; Ng, Andrea

    2014-01-01

    Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced volumes and doses is addressed, integrating modern imaging with 3-dimensional (3D) planning and advanced techniques of treatment delivery. The previously applied extended field (EF) and original involved field (IF) techniques, which treated larger volumes based on nodal stations, have now been replaced by the use of limited volumes, based solely on detectable nodal (and extranodal extension) involvement at presentation, using contrast-enhanced computed tomography, positron emission tomography/computed tomography, magnetic resonance imaging, or a combination of these techniques. The International Commission on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom optimal imaging is available, is explained. A new concept, involved site radiation therapy (ISRT), is introduced as the standard conformal therapy for the scenario, commonly encountered, wherein optimal imaging is not available. There is increasing evidence that RT doses used in the past are higher than necessary for disease control in this era of combined modality therapy. The use of INRT and of lower doses in early-stage HL is supported by available data. Although the

  11. High-dose irradiation of food

    International Nuclear Information System (INIS)

    Diehl, J.F.

    1999-01-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [de

  12. Technical Note: Comparison of peripheral patient dose from MR-guided 60 Co therapy and 6 MV linear accelerator IGRT.

    Science.gov (United States)

    Hauri, Pascal; Hälg, Roger A; Schneider, Uwe

    2017-07-01

    The use of X-ray imaging in radiation therapy can give a substantial dose to the patient. A Cobalt machine combined with an magnetic resonance imaging (MRI) was recently introduced to clinical work. One positive aspect of using non-ionizing imaging devices is the reduction of the patient exposure. The purpose of this study was to quantify the difference in out-of-field dose to the patient between the image guided radiation therapy (IGRT) treatment applied with a linear accelerator with cone beam CT (CBCT) equipment and a Cobalt machine combined with an MRI. The treatment of a rhabdomyosarcoma in the prostate was planned and irradiated using different modalities and radiation therapy machines. The whole-body dose was measured for a 3D-conformal radiation therapy (3DCRT), an intensity-modulated radiation therapy (IMRT), and a volumetric-modulated arc therapy plan applied with a conventional linear accelerator operated at 6 MV beam energy. Additionally, the dose of an IMRT plan applied with a 60 Co machine combined with an MRI was measured. Furthermore, the dose of one CBCT scan using the linear accelerator's on-board imaging system was determined. The 3D dose measurements were performed in an anthropomorphic phantom containing 168 slots for thermoluminescence dosimeters (TLDs). A combination of LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P (TLD100H) was used to accurately determine the in- and out-of-field dose. The plans were rescaled to different fractionation schemes (2 Gy, 3 Gy, and 5 Gy fraction dose) and the dose of one CBCT scan was additionally added to the treatment dose per fraction applied with the linear accelerator. The resulting absorbed doses per fraction of the two machines were compared. In the target region, all measured treatment plans presented the same magnitude of dose, while the CBCT dose was a factor of 100 smaller. Close to the planned target volume (PTV), the dose from the 60 Co machine was a factor of two higher compared with the 3DCRT + CBCT dose. Up

  13. ''Low dose'' and/or ''high dose'' in radiation protection: A need to setting criteria for dose classification

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1997-01-01

    The ''low dose'' and/or ''high dose'' of ionizing radiation are common terms widely used in radiation applications, radiation protection and radiobiology, and natural radiation environment. Reading the title, the papers of this interesting and highly important conference and the related literature, one can simply raise the question; ''What are the levels and/or criteria for defining a low dose or a high dose of ionizing radiation?''. This is due to the fact that the criteria for these terms and for dose levels between these two extreme quantities have not yet been set, so that the terms relatively lower doses or higher doses are usually applied. Therefore, setting criteria for classification of radiation doses in the above mentioned areas seems a vital need. The author while realizing the existing problems to achieve this important task, has made efforts in this paper to justify this need and has proposed some criteria, in particular for the classification of natural radiation areas, based on a system of dose limitation. (author)

  14. EDITORIAL Complexity of advanced radiation therapy necessitates multidisciplinary inquiry into dose reconstruction and risk assessment Complexity of advanced radiation therapy necessitates multidisciplinary inquiry into dose reconstruction and risk assessment

    Science.gov (United States)

    Newhauser, Wayne

    2010-07-01

    from the symposium are interrelated and focus on dose and risk assessments related to radiation exposures from advanced radiation therapies. These research topics have become increasingly complex and require the combined expertise of researchers with highly specialized and diverse investigational skills. Innovative multidisciplinary teams will be needed to achieve breakthroughs and, ultimately, to translate the research into clinical practice (Disis and Slattery 2010). The symposium's scientific goals included fostering and promoting such multidisciplinary teams, which will work to solve these complex problems and thereby improve cancer outcomes. To help clarify how the 13 articles each contribute to the goal of improving cancer outcomes, a brief digression is necessary. The proportion of patients surviving their cancers for five years or more is large and increasing (Jemal et al 2009). Unfortunately, in survivors who received radiation therapy, the prevalence of radiogenic late effects is likewise large and increasing (cf Altekruse et al 2010, Meadows et al 2009, Hudson et al 2009, Friedman et al 2010), with the potential to become a public health issue of considerable scale (Travis 2006). A multitude of late effects are associated with radiation exposure, including the development of second cancers, cardiac toxicity, cognitive deficits, and musculoskeletal growth abnormalities in children. In modern radiation therapy, much effort is devoted to developing personalized treatments that control the tumor while minimizing acute toxicities to surrounding healthy tissues; comparatively less attention has been paid to minimizing late effects (Durante and Loeffler 2010). In recent years, however, there has been an encouraging increase in research activities seeking to quantify radiation exposures (Stovall et al 2006) and the associated risks of late effects from modern external-beam therapies (Xu et al 2008). In this issue, Zhang et al (2010) report on Monte Carlo and

  15. Dose-Effect Relationships for Adverse Events After Cranial Radiation Therapy in Long-term Childhood Cancer Survivors

    International Nuclear Information System (INIS)

    Dijk, Irma W.E.M. van; Cardous-Ubbink, Mathilde C.; Pal, Helena J.H. van der; Heinen, Richard C.; Leeuwen, Flora E. van; Oldenburger, Foppe; Os, Rob M. van; Ronckers, Cécile M.; Schouten–van Meeteren, Antoinette Y.N.; Caron, Huib N.; Koning, Caro C.E.; Kremer, Leontien C.M.

    2013-01-01

    Purpose: To evaluate the prevalence and severity of clinical adverse events (AEs) and treatment-related risk factors in childhood cancer survivors treated with cranial radiation therapy (CRT), with the aim of assessing dose-effect relationships. Methods and Materials: The retrospective study cohort consisted of 1362 Dutch childhood cancer survivors, of whom 285 were treated with CRT delivered as brain irradiation (BI), as part of craniospinal irradiation (CSI), and as total body irradiation (TBI). Individual CRT doses were converted into the equivalent dose in 2-Gy fractions (EQD 2 ). Survivors had received their diagnoses between 1966 and 1996 and survived at least 5 years after diagnosis. A complete inventory of Common Terminology Criteria for Adverse Events grade 3.0 AEs was available from our hospital-based late-effect follow-up program. We used multivariable logistic and Cox regression analyses to examine the EQD 2 in relation to the prevalence and severity of AEs, correcting for sex, age at diagnosis, follow-up time, and the treatment-related risk factors surgery and chemotherapy. Results: There was a high prevalence of AEs in the CRT group; over 80% of survivors had more than 1 AE, and almost half had at least 5 AEs, both representing significant increases in number of AEs compared with survivors not treated with CRT. Additionally, the proportion of severe, life-threatening, or disabling AEs was significantly higher in the CRT group. The most frequent AEs were alopecia and cognitive, endocrine, metabolic, and neurologic events. Using the EQD 2 , we found significant dose-effect relationships for these and other AEs. Conclusion: Our results confirm that CRT increases the prevalence and severity of AEs in childhood cancer survivors. Furthermore, analyzing dose-effect relationships with the cumulative EQD 2 instead of total physical dose connects the knowledge from radiation therapy and radiobiology with the clinical experience

  16. Dose-Effect Relationships for Adverse Events After Cranial Radiation Therapy in Long-term Childhood Cancer Survivors

    Energy Technology Data Exchange (ETDEWEB)

    Dijk, Irma W.E.M. van, E-mail: i.w.vandijk@amc.uva.nl [Department of Radiation Oncology, Academic Medical Center, Amsterdam (Netherlands); Cardous-Ubbink, Mathilde C. [Department of Medical Oncology, Academic Medical Center, Amsterdam (Netherlands); Pal, Helena J.H. van der [Department of Medical Oncology, Academic Medical Center, Amsterdam (Netherlands); Department of Pediatric Oncology, Emma Children' s Hospital/Academic Medical Center, Amsterdam (Netherlands); Heinen, Richard C. [Department of Pediatric Oncology, Emma Children' s Hospital/Academic Medical Center, Amsterdam (Netherlands); Leeuwen, Flora E. van [Department of Epidemiology, Netherlands Cancer Institute, Amsterdam (Netherlands); Oldenburger, Foppe; Os, Rob M. van [Department of Radiation Oncology, Academic Medical Center, Amsterdam (Netherlands); Ronckers, Cécile M. [Dutch Childhood Oncology Group, Long-term Effects after Childhood Cancer, The Hague (Netherlands); Schouten–van Meeteren, Antoinette Y.N. [Department of Pediatric Oncology, Emma Children' s Hospital/Academic Medical Center, Amsterdam (Netherlands); Caron, Huib N. [Department of Medical Oncology, Academic Medical Center, Amsterdam (Netherlands); Department of Pediatric Oncology, Emma Children' s Hospital/Academic Medical Center, Amsterdam (Netherlands); Koning, Caro C.E. [Department of Radiation Oncology, Academic Medical Center, Amsterdam (Netherlands); Kremer, Leontien C.M. [Department of Medical Oncology, Academic Medical Center, Amsterdam (Netherlands); Department of Pediatric Oncology, Emma Children' s Hospital/Academic Medical Center, Amsterdam (Netherlands)

    2013-03-01

    Purpose: To evaluate the prevalence and severity of clinical adverse events (AEs) and treatment-related risk factors in childhood cancer survivors treated with cranial radiation therapy (CRT), with the aim of assessing dose-effect relationships. Methods and Materials: The retrospective study cohort consisted of 1362 Dutch childhood cancer survivors, of whom 285 were treated with CRT delivered as brain irradiation (BI), as part of craniospinal irradiation (CSI), and as total body irradiation (TBI). Individual CRT doses were converted into the equivalent dose in 2-Gy fractions (EQD{sub 2}). Survivors had received their diagnoses between 1966 and 1996 and survived at least 5 years after diagnosis. A complete inventory of Common Terminology Criteria for Adverse Events grade 3.0 AEs was available from our hospital-based late-effect follow-up program. We used multivariable logistic and Cox regression analyses to examine the EQD{sub 2} in relation to the prevalence and severity of AEs, correcting for sex, age at diagnosis, follow-up time, and the treatment-related risk factors surgery and chemotherapy. Results: There was a high prevalence of AEs in the CRT group; over 80% of survivors had more than 1 AE, and almost half had at least 5 AEs, both representing significant increases in number of AEs compared with survivors not treated with CRT. Additionally, the proportion of severe, life-threatening, or disabling AEs was significantly higher in the CRT group. The most frequent AEs were alopecia and cognitive, endocrine, metabolic, and neurologic events. Using the EQD{sub 2}, we found significant dose-effect relationships for these and other AEs. Conclusion: Our results confirm that CRT increases the prevalence and severity of AEs in childhood cancer survivors. Furthermore, analyzing dose-effect relationships with the cumulative EQD{sub 2} instead of total physical dose connects the knowledge from radiation therapy and radiobiology with the clinical experience.

  17. Validation of contour-driven thin-plate splines for tracking fraction-to-fraction changes in anatomy and radiation therapy dose mapping

    International Nuclear Information System (INIS)

    Schaly, B; Bauman, G S; Battista, J J; Dyk, J Van

    2005-01-01

    The goal of this study is to validate a deformable model using contour-driven thin-plate splines for application to radiation therapy dose mapping. Our testing includes a virtual spherical phantom as well as real computed tomography (CT) data from ten prostate cancer patients with radio-opaque markers surgically implanted into the prostate and seminal vesicles. In the spherical mathematical phantom, homologous control points generated automatically given input contour data in CT slice geometry were compared to homologous control point placement using analytical geometry as the ground truth. The dose delivered to specific voxels driven by both sets of homologous control points were compared to determine the accuracy of dose tracking via the deformable model. A 3D analytical spherically symmetric dose distribution with a dose gradient of ∼10% per mm was used for this phantom. This test showed that the uncertainty in calculating the delivered dose to a tissue element depends on slice thickness and the variation in defining homologous landmarks, where dose agreement of 3-4% in high dose gradient regions was achieved. In the patient data, radio-opaque marker positions driven by the thin-plate spline algorithm were compared to the actual marker positions as identified in the CT scans. It is demonstrated that the deformable model is accurate (∼2.5 mm) to within the intra-observer contouring variability. This work shows that the algorithm is appropriate for describing changes in pelvic anatomy and for the dose mapping application with dose gradients characteristic of conformal and intensity modulated radiation therapy

  18. Validation of contour-driven thin-plate splines for tracking fraction-to-fraction changes in anatomy and radiation therapy dose mapping.

    Science.gov (United States)

    Schaly, B; Bauman, G S; Battista, J J; Van Dyk, J

    2005-02-07

    The goal of this study is to validate a deformable model using contour-driven thin-plate splines for application to radiation therapy dose mapping. Our testing includes a virtual spherical phantom as well as real computed tomography (CT) data from ten prostate cancer patients with radio-opaque markers surgically implanted into the prostate and seminal vesicles. In the spherical mathematical phantom, homologous control points generated automatically given input contour data in CT slice geometry were compared to homologous control point placement using analytical geometry as the ground truth. The dose delivered to specific voxels driven by both sets of homologous control points were compared to determine the accuracy of dose tracking via the deformable model. A 3D analytical spherically symmetric dose distribution with a dose gradient of approximately 10% per mm was used for this phantom. This test showed that the uncertainty in calculating the delivered dose to a tissue element depends on slice thickness and the variation in defining homologous landmarks, where dose agreement of 3-4% in high dose gradient regions was achieved. In the patient data, radio-opaque marker positions driven by the thin-plate spline algorithm were compared to the actual marker positions as identified in the CT scans. It is demonstrated that the deformable model is accurate (approximately 2.5 mm) to within the intra-observer contouring variability. This work shows that the algorithm is appropriate for describing changes in pelvic anatomy and for the dose mapping application with dose gradients characteristic of conformal and intensity modulated radiation therapy.

  19. Dose delivery study for a novel compact proton accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kraus, Kim Melanie

    2014-01-15

    Proton therapy has played an important role in the treatment of cancer with radiation therapy for more than 60 years. Active spot scanning to deliver highly conformal dose to the tumor has been developed. However, the availability of proton therapy to the patients is still limited, partly, due to the high costs and sizes of large proton therapy centers. Therefore, a novel compact proton single room facility based on a linear accelerator mounted on a gantry has been proposed, named TULIP (TUrning LInac for Proton therapy). This accelerator allows for active energy variation on a milliseconds time scale. This work aims to assess the possibilities of dose delivery with TULIP to exploit its beneficial features with respect to dose delivery. We developed a software tool, simulating the dose delivery to the tumor. By means of this software tool, we assessed different delivery methods and found 3D spot scanning to be superior to rotational dose delivery with regard to dose and irradiation time. In a second part, we expanded the investigations to dose delivery to moving targets. Due to fast energy variation, we found TULIP to be preferably suitable for rescanning, confirmed by irradiation times of only a few minutes.

  20. Dose delivery study for a novel compact proton accelerator

    International Nuclear Information System (INIS)

    Kraus, Kim Melanie

    2014-01-01

    Proton therapy has played an important role in the treatment of cancer with radiation therapy for more than 60 years. Active spot scanning to deliver highly conformal dose to the tumor has been developed. However, the availability of proton therapy to the patients is still limited, partly, due to the high costs and sizes of large proton therapy centers. Therefore, a novel compact proton single room facility based on a linear accelerator mounted on a gantry has been proposed, named TULIP (TUrning LInac for Proton therapy). This accelerator allows for active energy variation on a milliseconds time scale. This work aims to assess the possibilities of dose delivery with TULIP to exploit its beneficial features with respect to dose delivery. We developed a software tool, simulating the dose delivery to the tumor. By means of this software tool, we assessed different delivery methods and found 3D spot scanning to be superior to rotational dose delivery with regard to dose and irradiation time. In a second part, we expanded the investigations to dose delivery to moving targets. Due to fast energy variation, we found TULIP to be preferably suitable for rescanning, confirmed by irradiation times of only a few minutes.

  1. Dose-response relationship with radiotherapy: an evidence?

    International Nuclear Information System (INIS)

    Chauvet, B.; Rauglaudre, G. de; Mineur, L.; Alfonsi, M.; Reboul, F.

    2003-01-01

    The dose-response relationship is a fundamental basis of radiobiology. Despite many clinical data, difficulties remain to demonstrate a relation between dose and local control: relative role of treatment associated with radiation therapy (surgery, chemotherapy, hormonal therapy), tumor heterogeneity, few prospective randomized studies, uncertainty of local control assessment. Three different situations are discussed: tumors with high local control probabilities for which dose effect is demonstrated by randomized studies (breast cancer) or sound retrospective data (soft tissues sarcomas), tumors with intermediate local control probabilities for which dose effect seems to be important according to retrospective studies and ongoing or published phase III trials (prostate cancer), tumors with low local control probabilities for which dose effect appears to be modest beyond standard doses, and inferior to the benefit of concurrent chemotherapy (lung and oesophageal cancer). For head and neck tumors, the dose-response relationship has been explored through hyperfractionation and accelerated radiation therapy and a dose effect has been demonstrated but must be compared to the benefit of concurrent chemotherapy. Last but not least, the development of conformal radiotherapy allow the exploration of the dose response relationship for tumors such as hepatocellular carcinomas traditionally excluded from the field of conventional radiation therapy. In conclusion, the dose-response relationship remains a sound basis of radiation therapy for many tumors and is a parameter to take into account for further randomized studies. (author)

  2. Cost-effectiveness of single-dose tamsulosin and dutasteride combination therapy compared with tamsulosin monotherapy in patients with benign prostatic hyperplasia in the UK.

    Science.gov (United States)

    Walker, Anna; Doyle, Scott; Posnett, John; Hunjan, Manjit

    2013-09-01

    To estimate the long-term cost-effectiveness of single-dose dutasteride/tamsulosin combination therapy as a first-line treatment for benign prostatic hyperplasia (BPH) from the perspective of the UK National Health Service (NHS). A Markov state transition model was developed to estimate healthcare costs and patient outcomes, measured by quality-adjusted life years (QALYs), for patients aged ≥50 years with diagnosed BPH and moderate to severe symptoms. Costs and outcomes were estimated for two treatment comparators: oral, daily, single-dose combination therapy (dutasteride 0.5 mg + tamsulosin 0.4 mg), and oral daily tamsulosin (0.4 mg) over a period up to 25 years. The efficacy of comparators was taken from results of the Combination of Avodart and Tamsulosin (CombAT) trial. Cumulative discounted costs per patient were higher with combination therapy than with tamsulosin, but QALYs were also higher. After 25 years, the incremental cost-effectiveness ratio for combination therapy was £12,219, well within the threshold range (£20,000-£30,000 per QALY) typically applied in the NHS. Probabilistic sensitivity analysis showed that the probability of combination therapy being cost-effective given the threshold range is between 78% and 88%. Single-dose combination dutasteride/tamsulosin therapy has a high probability of being cost-effective in comparison to tamsulosin monotherapy in the UK's NHS. © 2013 BJU International.

  3. Assessment of dose load of personnel in intratissue gamma beam therapy

    International Nuclear Information System (INIS)

    Stavitskij, R.V.; Zamyatin, O.A.; Varennikov, O.I.; Astakhova, I.V.

    1995-01-01

    Suggest a method for retrospective assessment of levels of irradiation of small groups of personnel exposed to radiation sources. Presents estimated values of cumulative and local doses obtained by personnel during intratissue gamma beam therapy carried out by manual consecutive injections of intrastats and irradiation sources. 3 refs.; 5 tabs

  4. Cancer radiotherapy based on femtosecond IR laser-beam filamentation yielding ultra-high dose rates and zero entrance dose.

    Science.gov (United States)

    Meesat, Ridthee; Belmouaddine, Hakim; Allard, Jean-François; Tanguay-Renaud, Catherine; Lemay, Rosalie; Brastaviceanu, Tiberius; Tremblay, Luc; Paquette, Benoit; Wagner, J Richard; Jay-Gerin, Jean-Paul; Lepage, Martin; Huels, Michael A; Houde, Daniel

    2012-09-18

    Since the invention of cancer radiotherapy, its primary goal has been to maximize lethal radiation doses to the tumor volume while keeping the dose to surrounding healthy tissues at zero. Sadly, conventional radiation sources (γ or X rays, electrons) used for decades, including multiple or modulated beams, inevitably deposit the majority of their dose in front or behind the tumor, thus damaging healthy tissue and causing secondary cancers years after treatment. Even the most recent pioneering advances in costly proton or carbon ion therapies can not completely avoid dose buildup in front of the tumor volume. Here we show that this ultimate goal of radiotherapy is yet within our reach: Using intense ultra-short infrared laser pulses we can now deposit a very large energy dose at unprecedented microscopic dose rates (up to 10(11) Gy/s) deep inside an adjustable, well-controlled macroscopic volume, without any dose deposit in front or behind the target volume. Our infrared laser pulses produce high density avalanches of low energy electrons via laser filamentation, a phenomenon that results in a spatial energy density and temporal dose rate that both exceed by orders of magnitude any values previously reported even for the most intense clinical radiotherapy systems. Moreover, we show that (i) the type of final damage and its mechanisms in aqueous media, at the molecular and biomolecular level, is comparable to that of conventional ionizing radiation, and (ii) at the tumor tissue level in an animal cancer model, the laser irradiation method shows clear therapeutic benefits.

  5. Treatment dose-response in amblyopia therapy: the Monitored Occlusion Treatment of Amblyopia Study (MOTAS).

    Science.gov (United States)

    Stewart, Catherine E; Moseley, Merrick J; Stephens, David A; Fielder, Alistair R

    2004-09-01

    Amblyopia is the commonest visual disorder of childhood. Yet the contributions of the two principal treatments (spectacle wear and occlusion) to outcome are unknown. This study was undertaken to investigate the dose-response relationship of amblyopia therapy. The study comprised three distinct phases: baseline, in which repeat measures of visual function were undertaken to confirm the initial visual deficit; refractive adaptation: an 18-week period of spectacle wear with six weekly measurements of logarithm of the minimum angle of resolution (logMAR) visual acuity; occlusion: in which participants were prescribed 6 hours of "patching" per day. In the latter phase, occlusion was objectively monitored and logMAR visual acuity recorded at 2-week intervals until any observed gains had ceased. Data were obtained from 94 participants (mean age, 5.1 +/- 1.4 years) with amblyopia associated with strabismus (n = 34), anisometropia (n = 23), and both anisometropia and strabismus (n = 37). Eighty-six underwent refractive adaptation. Average concordance with patching was 48%. The relationship between logMAR visual acuity gain and total occlusion dose was monotonic and linear. Increasing dose rate beyond 2 h/d hastened the response but did not improve outcome. More than 80% of the improvement during occlusion occurred within 6 weeks. Treatment outcome was significantly better for children younger than 4 years (n = 17) than in those older than 6 years (n = 24; P = 0.0014). Continuous objective monitoring of the amount of patching therapy received has provided insight into the dose-response relationship of occlusion therapy for amblyopia. Patching is most effective within the first few weeks of treatment, even for those in receipt of a relatively small dose. Further studies are needed to elucidate the neural basis for the dose-response functions. Copyright Association for Research in Vision and Ophthalmology

  6. Development and validation of Monte Carlo dose computations for contrast-enhanced stereotactic synchrotron radiation therapy

    International Nuclear Information System (INIS)

    Vautrin, M.

    2011-01-01

    Contrast-enhanced stereotactic synchrotron radiation therapy (SSRT) is an innovative technique based on localized dose-enhancement effects obtained by reinforced photoelectric absorption in the tumor. Medium energy monochromatic X-rays (50 - 100 keV) are used for irradiating tumors previously loaded with a high-Z element. Clinical trials of SSRT are being prepared at the European Synchrotron Radiation Facility (ESRF), an iodinated contrast agent will be used. In order to compute the energy deposited in the patient (dose), a dedicated treatment planning system (TPS) has been developed for the clinical trials, based on the ISOgray TPS. This work focuses on the SSRT specific modifications of the TPS, especially to the PENELOPE-based Monte Carlo dose engine. The TPS uses a dedicated Monte Carlo simulation of medium energy polarized photons to compute the deposited energy in the patient. Simulations are performed considering the synchrotron source, the modeled beamline geometry and finally the patient. Specific materials were also implemented in the voxelized geometry of the patient, to consider iodine concentrations in the tumor. The computation process has been optimized and parallelized. Finally a specific computation of absolute doses and associated irradiation times (instead of monitor units) was implemented. The dedicated TPS was validated with depth dose curves, dose profiles and absolute dose measurements performed at the ESRF in a water tank and solid water phantoms with or without bone slabs. (author) [fr

  7. A dosimetry system for fast measurement of 3D depth-dose profiles in charged-particle tumor therapy with scanning techniques

    International Nuclear Information System (INIS)

    Brusasco, C.; Voss, B.; Schardt, D.; Kraemer, M.; Kraft, G.

    2000-01-01

    The high complexity and high instantaneous dose rates of the intensity modulated treatment plans performed using carbon beams at GSI require a good granularity of the dose verification procedures. As a consequence, a new detector system was developed in order to obtain a 3D reconstruction of the relative depth-dose distributions in a short time, with high granularity and over large volumes. The system takes advantage of the active beam delivery system operative in the therapy facility of GSI and consists of one position sensitive detector with a stack of ionization chambers and a range-shifter. After a technical description of the apparatus, the procedure to reconstruct the 3D measurements is explained and the possible sources of errors in the measurements are analyzed. Finally, the results of the measurement of some treatment plans are shown

  8. Use of a concise prescription for specifying absolute dose distribution in external beam radiation therapy

    International Nuclear Information System (INIS)

    Viggers, D.A.; Shalev, S.

    1989-01-01

    Radiation therapy dose distributions are usually calculated relative to some normalization point to which a prescribed dose in grays is to be delivered. Often the radiation therapist requests that the prescribed dose be delivered to some other point(s), such as the 90% isodose. Therefore the prescribed dose is not well defined. Furthermore, this procedure leaves the shape of the dose distribution unspecified. The authors have used a dose prescription specifying the volumes of target and nontarget tissue that must lie within dose limits stated in grays. These dose-volume limits determine the magnitude and shape of the dose distribution. The prescription is well defined while allowing the absolute dose at a chosen point to be adjusted so that the dose distribution satisfies the prescription

  9. Biochemical criteria of toxicity of therapy with high doses of methotrexate in children with osteosarcoma

    Directory of Open Access Journals (Sweden)

    A. M. Strizhevskaya

    2015-01-01

    Full Text Available Methotrexate (Mtx is a cytotoxic drug from the group of antimetabolites, folic acid antagonists. High-dose (HD Mtx in pediatric oncology are used for the treatment of osteosarcoma (OS, and other types of tumors. This therapy has allowed to achieve a five-year relapse-free survival rates up to 80 % in patients with OS. However, the high toxicity of Mtx is a serious constraint in achieving the maximum therapeutic effect, which in most cases poses the occurrence of side effects in patients on various organs and systems. Treatment should be under strict laboratory monitoring, primarily therapeutic drug monitoring the concentration of Mtx in serum.246 children (boys – 125, girls – 121 aged 5 to 16 years with osteosarcoma (mean age 12.2 years who were treated in N.N. Blokhin Russian Cancer Research Center from 2006 to 2013. Patients were conducted from 1 to 8 courses HD Mtx at a dose of 8 or 12 g/m2 , administered within 4 h of infusion on the background of alkaline prehydrate. Leucovorin was administered intravenously, every 6 hours, starting 24 h from the start of the Mtx infusion. 1137 courses of HD Mtx were conducted with FPIA method (analyzer TDx/Flx, Abbott, USA. The technique of monitoring of homocysteine (Hcy in the blood serum by analyzer Vitros 5/1FS (Johnson & Johnson, USA during the entire course of high-dose Mtx was tested. In groups calculated pharmacokinetic parameters Mtx were tested: area under the pharmacokinetic curve (MtxAUC, clearance of methotrexate (ClMtx, the elimination half-life (T1/2 and the total time of excretion (Ttotal. Normal excretion of Mtx was revealed at 1050 courses Mtx, corresponding to the following values: 4 h – 1109 ± 283 μmol/l; 24 h – 4,67 ± 0,95 μmol/l; 42 h – 0,38 ± 0.16 µmol/l; 48 h – less than 0,23 ± 0.04 µmol/l; 72 h of 0.07 ± 0,03 µmol/l; 96 h of 0.03 ± 0.01 µmol/l. At 87 courses identified delayed Mtx excretion, accounting for 7.6 % of all courses. In all measured parameters

  10. Analysis of renal impairment in MM-003, a phase III study of pomalidomide + low - dose dexamethasone versus high - dose dexamethasone in refractory or relapsed and refractory multiple myeloma

    Science.gov (United States)

    Weisel, Katja C.; Dimopoulos, Meletios A.; Moreau, Philippe; Lacy, Martha Q.; Song, Kevin W.; Delforge, Michel; Karlin, Lionel; Goldschmidt, Hartmut; Banos, Anne; Oriol, Albert; Alegre, Adrian; Chen, Christine; Cavo, Michele; Garderet, Laurent; Ivanova, Valentina; Martinez-Lopez, Joaquin; Knop, Stefan; Yu, Xin; Hong, Kevin; Sternas, Lars; Jacques, Christian; Zaki, Mohamed H.; Miguel, Jesus San

    2016-01-01

    Pomalidomide + low-dose dexamethasone is effective and well tolerated for refractory or relapsed and refractory multiple myeloma after bortezomib and lenalidomide failure. The phase III trial MM-003 compared pomalidomide + low-dose dexamethasone with high-dose dexamethasone. This subanalysis grouped patients by baseline creatinine clearance ≥ 30 − < 60 mL/min (n=93, pomalidomide + low-dose dexamethasone; n=56, high-dose dexamethasone) or ≥ 60 mL/min (n=205, pomalidomide + low-dose dexamethasone; n=93, high-dose dexamethasone). Median progression-free survival was similar for both subgroups and favored pomalidomide + low-dose dexamethasone versus high-dose dexamethasone: 4.0 versus 1.9 months in the group with baseline creatinine clearance ≥ 30 − < 60 mL/min (P<0.001) and 4.0 versus 2.0 months in the group with baseline creatinine clearance ≥ 60 mL/min (P<0.001). Median overall survival for pomalidomide + low-dose dexamethasone versus high-dose dexamethasone was 10.4 versus 4.9 months (P=0.030) and 15.5 versus 9.2 months (P=0.133), respectively. Improved renal function, defined as an increase in creatinine clearance from < 60 to ≥ 60 mL/min, was similar in pomalidomide + low-dose dexamethasone and high-dose dexamethasone patients (42% and 47%, respectively). Improvement in progression-free and overall survival in these patients was comparable with that in patients without renal impairment. There was no increase in discontinuations of therapy, dose modifications, and adverse events in patients with moderate renal impairment. Pomalidomide at a starting dose of 4 mg + low-dose dexamethasone is well tolerated in patients with refractory or relapsed and refractory multiple myeloma, and of comparable efficacy if moderate renal impairment is present. This trial was registered with clinicaltrials.gov identifier 01311687 and EudraCT identifier 2010-019820-30. PMID:27081177

  11. Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Adkison, Jarrod B.; McHaffie, Derek R.; Bentzen, Soren M.; Patel, Rakesh R.; Khuntia, Deepak [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Petereit, Daniel G. [Department of Radiation Oncology, John T. Vucurevich Regional Cancer Care Institute, Rapid City Regional Hospital, Rapid City, SD (United States); Hong, Theodore S.; Tome, Wolfgang [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Ritter, Mark A., E-mail: ritter@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States)

    2012-01-01

    Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose

  12. Evolution of calculation models for the proton-therapy dose planning software

    International Nuclear Information System (INIS)

    Vidal, Marie

    2011-01-01

    This work was achieved in collaboration between the Institut Curie Proton-therapy Center of Orsay (ICPO), the DOSIsoft company and the CREATIS laboratory, in order to develop a new dose calculation model for the new ICPO treatment room. A new accelerator and gantry room from the IBA company were installed during the up-grade project of the proton-therapy center, with the intention of enlarging the cancer localizations treated at ICPO. Developing a package of methods and new dose calculation algorithms to adapt them to the new specific characteristics of the delivered beams by the IBA system is the first goal of this PhD work. They all aim to be implemented in the DOSIsoft treatment planning software, Isogray. First, the double scattering technique is treated in taking into account major differences between the IBA system and the ICPO fixed beam lines passive system. Secondly, a model is explored for the scanned beams modality. The second objective of this work is improving the Ray-Tracing and Pencil-Beam dose calculation models already in use. For the double scattering and uniform scanning techniques, the patient personalized collimator at the end of the beam line causes indeed a patient dose distribution contamination. A reduction method of that phenomenon was set up for the passive beam system. An analytical model was developed which describes the contamination function with parameters validated through Monte-Carlo simulations on the GATE platform. It allows us to apply those methods to active scanned beams. (author) [fr

  13. SU-E-T-37: A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy

    International Nuclear Information System (INIS)

    Kalantzis, G; Leventouri, T; Tachibana, H; Shang, C

    2015-01-01

    Purpose: Recent developments in radiation therapy have been focused on applications of charged particles, especially protons. Over the years several dose calculation methods have been proposed in proton therapy. A common characteristic of all these methods is their extensive computational burden. In the current study we present for the first time, to our best knowledge, a GPU-based PBA for proton dose calculations in Matlab. Methods: In the current study we employed an analytical expression for the protons depth dose distribution. The central-axis term is taken from the broad-beam central-axis depth dose in water modified by an inverse square correction while the distribution of the off-axis term was considered Gaussian. The serial code was implemented in MATLAB and was launched on a desktop with a quad core Intel Xeon X5550 at 2.67GHz with 8 GB of RAM. For the parallelization on the GPU, the parallel computing toolbox was employed and the code was launched on a GTX 770 with Kepler architecture. The performance comparison was established on the speedup factors. Results: The performance of the GPU code was evaluated for three different energies: low (50 MeV), medium (100 MeV) and high (150 MeV). Four square fields were selected for each energy, and the dose calculations were performed with both the serial and parallel codes for a homogeneous water phantom with size 300×300×300 mm3. The resolution of the PBs was set to 1.0 mm. The maximum speedup of ∼127 was achieved for the highest energy and the largest field size. Conclusion: A GPU-based PB algorithm for proton dose calculations in Matlab was presented. A maximum speedup of ∼127 was achieved. Future directions of the current work include extension of our method for dose calculation in heterogeneous phantoms

  14. A prospective randomized study concerning the point a dose in high-dose rate intracavitary therapy for carcinoma of the uterine cervix. The final results

    International Nuclear Information System (INIS)

    Chatani, M.; Matayoshi, Y.; Masaki, N.; Teshima, T.; Inoue, T.

    1994-01-01

    Between January 1983 and February 1989, a total of 165 patients with carcinoma of the unterine cervix was entered in a prospective randomized study concerning the point A dose of HDR therapy (6 Gy/fraktion vs 7.5 Gy/fraction) and external irradiation dose at Department of Radiation Therapy, The Center for Adult Diseases, Osaka. UICC stage distribution of patients was as follows: Stage IA=4, stage IB=33, stage IIA=18, stage IIB=38, stage III=57, stage IV=15. Overall 5-year cause specific survivals were as follows: Stage IA=100%, stage IB=96%, stage IIA=92%, stage IIB=79%, stage III=57%, stage IV=27%. In each stage, 5-year survival rates in groups A and B were 100%, 93% in stage I, 82% and 85% in stage II, 62% and 52% in stage II and 22% and 31% in stage IV, respectively. There were no statistically significant differences among these survival curves in each stage. Five-year local failure rates were 16% in group A and 16% in group B (p=0.9096), and corresponding distant failure rates were 23% in group A and 19% in group B (p=0.2955). Moderate-to-severe complications requiring treatment (Kottmeier's grade 2 or more) were noted in 6 patients (7%) in group A and 6 patients (7%) in group B. All of the bladder and rectal complications needed medical treatment (Kottmeier's grade 2). Severe complications receiving surgery were noted in 4 patients (A: 1; B: 3), i.e., small intestine 3 and sigmoid colon 1 patient. Another 1 patient (A) was dead of ileus. There were no statistically significant differences between 2 treatment schedules in survival rates, failure patterns and complications rates. This fact suggests that small number of fractions (7.5 Gy/fraction) may be advantageous because of short duration and a low load of treatment. (orig.) [de

  15. Gafchromic EBT‐XD film: Dosimetry characterization in high‐dose, volumetric‐modulated arc therapy

    Science.gov (United States)

    Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi

    2016-01-01

    Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT‐XD films have been designed for optimal performance in the 40–4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose‐response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high‐dose volumetric‐modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0–4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter‐free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose‐rate dependence. For clinical examinations, we compared the dose distribution measured with EBT‐XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT‐XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ∼3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ∼1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ∼1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film‐ measured and treatment planning system (TPS)‐calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. PACS number(s): 87.56 Fc PMID:27929504

  16. Radiation Sialadenitis Induced by High-dose Radioactive Iodine Therapy

    International Nuclear Information System (INIS)

    Jeong, Shin Young; Lee, Jaetae

    2010-01-01

    Radioactive iodine ( 131 I) is accumulated in the thyroid tissue and plays an important role in the treatment of differentiated papillary and follicular cancers after thyroidectomy. Simultaneously, 131 I is concentrated in the salivary glands and secreted into the saliva. Dose-related damage to the salivary parenchyma results from the 131 I irradiation. Salivary gland swelling and pain, usually involving the parotid, can be seen. The symptoms may develop immediately after a therapeutic dose of 131 I and/or months later and progress in intensity with time. In conjunction with the radiation sialadenitis, secondary complications reported include xerostomia, taste alterations, infection, increases in caries, facial nerve involvement, candidiasis, and neoplasia. Prevention of 131 I sialadenitis may involve the use of sialogogic agents to hasten the transit time of the radioactive iodine through the salivary glands. However, studies are not available to delineate the efficacy of this approach. Treatment of the varied complications that may develop encompass numerous approaches and include gland massage, sialogogic agents, duct probing, antibiotics, mouthwashes, good oral hygiene, and adequate hydration. Recently interventional sialoendoscopy has been introduced an effective tool for the management of patients with 131 I-induced sialadenitis that is unresponsive to medical treatment.

  17. Successful treatment of azole-resistant invasive aspergillosis in a bottlenose dolphin with high-dose posaconazole

    Directory of Open Access Journals (Sweden)

    Paulien E. Bunskoek

    2017-06-01

    Full Text Available Invasive aspergillosis due to azole-resistant Aspergillus fumigatus is difficult to manage. We describe a case of azole-resistant invasive aspergillosis in a female bottlenose dolphin, who failed to respond to voriconazole and posaconazole therapy. As intravenous therapy was precluded, high dose posaconazole was initiated aimed at achieving trough levels exceeding 3 mg/l. Posaconazole serum levels of 3–9.5 mg/l were achieved without significant side-effects. Follow-up bronchoscopy and computed tomography showed complete resolution of the lesions.

  18. Systemic high-dose methotrexate plus ifosfamide is highly effective for central nervous system (CNS) involvement of lymphoma

    OpenAIRE

    2008-01-01

    Abstract Patients with malignant central nervous system (CNS) involvement of lymphoma have a poor prognosis with intrathecal chemotherapy and radiation. In this paper, we report the results we obtained in such patients by intravenous chemotherapy with high-dose methotrexate and ifosfamide (HDMTX/IFO). The study involved a review of all patients who received HDMTX/IFO for CNS involvement of malignant lymphoma at our hospital. Therapy consisted of 4 g/m2 of MTX (4 h infu...

  19. Dose-reduction techniques for high-dose worker groups in nuclear power plants

    International Nuclear Information System (INIS)

    Khan, T.A.; Baum, J.W.; Dionne, B.J.

    1991-03-01

    This report summarizes the main findings of a study of the extent of radiation dose received by special work groups in the nuclear power industry. Work groups which chronically get large doses were investigated, using information provided by the industry. The tasks that give high doses to these work groups were examined and techniques described that were found to be particularly successful in reducing dose. Quantitative information on the extent of radiation doses to various work groups shows that significant numbers of workers in several critical groups receive doses greater than 1 and even 2 rem per year, particularly contract personnel and workers at BWR-type plants. The number of radiation workers whose lifetime dose is greater than their age is much less. Although the techniques presented would go some way in reducing dose, it is likely that a sizeable reduction to the high-dose work groups may require development of new dose-reduction techniques as well as major changes in procedures. 10 refs., 26 tabs

  20. Dose impact of a carbon fiber couch for stereotactic body radiation therapy of lung tumors

    International Nuclear Information System (INIS)

    Tominaga, Hirofumi; Kanetake, Nagisa; Kawasaki, Keiichi; Iwashita, Yuki; Sakata, Junichi; Okuda, Tomoko; Araki, Fujio; Shimohigashi, Yoshinobu; Tomiyama, Yuki

    2013-01-01

    The aim of this study was to measure the dose attenuation caused by a carbon fiber radiation therapy table (Imaging Couch Top; ICT, BrainLab) and to evaluate the dosimetric impact of ICT during stereotactic body radiation therapy (SBRT) in lung tumors. The dose attenuation of ICT was measured using an ionization chamber and modeled by means of a treatment planning system (TPS). SBRT was planned with and without ICT in a lung tumor phantom and ten cases of clinical lung tumors. The results were analyzed from isocenter doses and a dose-volume histogram (DVH): D 95 , D mean , V 20 , V 5 , homogeneity index (HI), and conformity index (CI). The dose attenuation of the ICT modeled with TPS agreed to within ±1% of the actually measured values. The isocenter doses, D 95 and D mean with and without ICT showed differences of 4.1-5% for posterior single field and three fields in the phantom study, and differences of 0.6-2.4% for five fields and rotation in the phantom study and six fields in ten clinical cases. The dose impact of ICT was not significant for five or more fields in SBRT. It is thus possible to reduce the dose effect of ICT by modifying the beam angle and beam weight in the treatment plan. (author)